Sample records for impregnated foam dressing

  1. Cost-effectiveness Analysis of Silver Delivery Approaches in the Management of Partial-thickness Burns.

    PubMed

    Nherera, Leo; Trueman, Paul; Roberts, Christopher; Berg, Leena

    2018-02-23

    Burn injury is a common type of traumatic injury that causes considerable morbidity and mortality, resulting in about 30,000 admissions annually in specialist burn centers and costing around $1 billion per year in the United States. One percent silver sulfadiazine has been utilized widely in the management of burns and newer silver dressings are on the market, including nanocrystalline silver dressings, silver-impregnated hydrofiber dressings, and silver-impregnated foam dressings. This study sought to determine the cost effectiveness of the newer silver dressings using clinical data from an indirect treatment comparison using silver sulfadiazine as the baseline. A decision analytic model was developed from a US payer's perspective for burn patients with a total body surface area of < 20%. Outcomes were length of stay, infections and incidence of surgical procedures, quality adjusted life years (QALYs), and cost. The meta-analysis reported a statistically significant reduction in length of hospital stay and clinically important reductions in infections and incidence of surgical procedures in favor of the silver barrier dressing compared with other silver dressings. The estimated QALYs were 0.970 versus 0.969 versus 0.969 and mean cost per patient was $15,892, $23,799, and $24,269 for the nanocrystalline silver dressing, silver-impregnated hydrofiber dressing, and silver-impregnated foam dressing, respectively. The analysis showed the nanocrystalline silver dressing to be a dominant strategy (less costly with better outcomes). These findings were robust to a range of sensitivity analyses. According to data from an indirect treatment comparison, this analysis suggests that nanocrystalline silver dressing is the most cost-effective silver delivery system. Prospective head-to-head research on the costs and outcomes of these silver delivery systems in this patient population is necessary to validate the results of this economic evaluation.

  2. Antimicrobial Activity of a Novel Vascular Access Film Dressing Containing Chlorhexidine Gluconate.

    PubMed

    Wibaux, Anne; Thota, Priyaleela; Mastej, Jozef; Prince, Daniel L; Carty, Neal; Johnson, Peter

    2015-01-01

    Covering insertion sites with chlorhexidine impregnated dressings has been proven to be clinically effective in reducing catheter related blood stream infections (CR-BSI). Two chlorhexidine gluconate (CHG)-impregnated dressings are commercially available, a polyurethane foam disk and a film dressing containing a chlorhexidine gluconate-impregnated gel pad. While both have demonstrated efficacy in clinical settings, the major drawback of high cost and impaired IV insertion site visibility limits their usage. A new, simple film dressing containing CHG within its adhesive layer is now available. The objective of this study was to test the in vitro antimicrobial efficacy of the new dressing in comparison to the CHG-impregnated gel dressing. Quantitative aliquots of suspensions (concentration of 1.0x106 to 5.0x106 cfu/sample) of clinically relevant challenge organisms (Staphylococcus species, gram-negative bacilli, Candida albicans) were incubated in contact with the new CHG-containing film dressing, a placebo version of the same (negative control) and the commercially available CHG-impregnated gel dressing (positive control). Serial dilutions of the surviving organisms were quantified using the pour plate after 1, 3, 5, and 7 days of incubation in order to calculate an antimicrobial log10 reduction for each organism/dressing combination at each point in time. The new CHG-containing film dressing delivered greater than 5.0 log10 reduction throughout the 7 days on all aerobic gram-negative bacilli and Staphylococcus species tested. As of day 1 the CHG-containing film dressing provided greater than 5.0 log10 reduction on Candida albicans. There were no statistically significant differences in the log10 reduction between the two dressings tested. The new CHG-containing film dressing was found to be as effective as the chlorhexidine gluconate-impregnated gel dressing on clinically relevant microbes.

  3. Antimicrobial Activity of a Novel Vascular Access Film Dressing Containing Chlorhexidine Gluconate

    PubMed Central

    Wibaux, Anne; Thota, Priyaleela; Mastej, Jozef; Prince, Daniel L.; Carty, Neal; Johnson, Peter

    2015-01-01

    Background Covering insertion sites with chlorhexidine impregnated dressings has been proven to be clinically effective in reducing catheter related blood stream infections (CR-BSI). Two chlorhexidine gluconate (CHG)-impregnated dressings are commercially available, a polyurethane foam disk and a film dressing containing a chlorhexidine gluconate-impregnated gel pad. While both have demonstrated efficacy in clinical settings, the major drawback of high cost and impaired IV insertion site visibility limits their usage. A new, simple film dressing containing CHG within its adhesive layer is now available. The objective of this study was to test the in vitro antimicrobial efficacy of the new dressing in comparison to the CHG-impregnated gel dressing. Methods Quantitative aliquots of suspensions (concentration of 1.0x106 to 5.0x106 cfu/sample) of clinically relevant challenge organisms (Staphylococcus species, gram-negative bacilli, Candida albicans) were incubated in contact with the new CHG-containing film dressing, a placebo version of the same (negative control) and the commercially available CHG-impregnated gel dressing (positive control). Serial dilutions of the surviving organisms were quantified using the pour plate after 1, 3, 5, and 7 days of incubation in order to calculate an antimicrobial log10 reduction for each organism/dressing combination at each point in time. Results The new CHG-containing film dressing delivered greater than 5.0 log10 reduction throughout the 7 days on all aerobic gram-negative bacilli and Staphylococcus species tested. As of day 1 the CHG-containing film dressing provided greater than 5.0 log10 reduction on Candida albicans. There were no statistically significant differences in the log10 reduction between the two dressings tested. Conclusion The new CHG-containing film dressing was found to be as effective as the chlorhexidine gluconate-impregnated gel dressing on clinically relevant microbes. PMID:26599087

  4. The Use of Vacuum-Assisted Closure and GranuFoam Silver® Dressing in the Management of Diabetic Foot Ulcer.

    PubMed

    Günal, Özgür; Tuncel, Umut; Turan, Aydin; Barut, Sener; Kostakoglu, Naci

    2015-10-01

    The aim of this retrospective study was to evaluate the efficacy of vacuum-assisted closure (VAC) and GranuFoam Silver® dressing (KCI, San Antonio, TX) compared with conventional GranuFoam® dressing in the management of diabetic foot ulcers. Twenty-one consecutive patients treated with conventional or silver-coated foam dressing were reviewed retrospectively. The wound duration was 6 mo. Group 1 (n=10) received conventional foam dressing (GranuFoam) and group 2 (n=11) received silver-coated foam dressing (GranuFoam Silver). The wound surface area, duration of treatment, bacteriology, and recurrence were compared between the groups. The mean age of the patients was 61.70±10.52 y in group 1 and 67.27±11.28 y in group 2. In group 1, the average surface area of the wounds was 45.30±46.96 cm2 and 18.40±23.48 cm2 in the pre-treatment and post-treatment periods, respectively. There was a statistically significant difference between two measurements (p=0.005). Average duration of the treatment was 25.50±27.13 d in this group. In group 2, average surface area of the wounds in the pre-treatment and post-treatment periods were 41.55±36.03 cm2 and 7.64±3.91 cm2, respectively. There was a statistically significant difference between two measurements (p=0.003). Average duration of the treatment was 10.09±3.51 d in this group. The patients treated with silver-impregnated polyurethane foam dressing had reduced recurrence (2 vs. 7 wounds, p=0.030) and increased number of the culture-negative cases at the end of the treatment. With the results of the study, it was concluded that VAC GranuFoam silver dressing can be superior to conventional GranuFoam dressing in reducing the recurrence rate of infected diabetic foot ulcers.

  5. Antimicrobial Efficacy of a Silver Impregnated Hydrophilic PU Foam.

    PubMed

    Percival, Steven L

    2018-06-01

    A novel hydrophilic polyurethane (PU) foam dressing which is impregnated with silver chloride, Optifoam® Gentle (OG) Ag+ (Medline Industries Inc., Chicago, Illinois), was evaluated in this study. The aims of this study were to determine the rate of elution of silver from the foam dressing over a period of 168 hours into simulated wound fluid and an evaluation of antimicrobial efficacy using zone of inhibition (ZOI), direct kill, and time-kill viability. Thirty-two microorganisms associated with wounds including Pseudomonas aeruginosa, Methicillin sensitive Staphylococcus aureus (MSSA), Acinetobacter baumannii, Candida albicans, and antibiotic-resistant strains (Methicillin-resistant S. aureus [MRSA] and Vancomycin-resistant Enterococci [VRE]) were evaluated. Silver release from the wound dressing showed an exponential curve with a stable sustained release of 25ppm achieved after 24 hours, which was maintained for the full duration of the study. OG Ag+ caused inhibition zones ranging from 4-16mm after a 24-hour contact time. In the direct kill assay, OG Ag+ reduced the microbial numbers below the limit of detection and reduced viability by a log of four within 24 hours. For the time-kill viability studies, the results support the use of this hydrophilic polyurethane foam as a wound dressing for use in wounds at risk of infection or infected by achieving a four log kill within six hours and a six log kill in 16 hours. In conclusion, OG Ag+ was shown to be an effective wound dressing in the killing of a range of important opportunistic pathogens of relevance to wound healing and infections. Achieving a six log kill against S. aureus and E.coli, within 16 hours in the time kill assay, (ASTM E2315-03) demonstrates that OG Ag+ should be an important addition to the armoury available for the management of acute and chronic wounds at risk of infection or clinically infected.

  6. Silver-containing foam dressings with Safetac: a review of the scientific and clinical data.

    PubMed

    Davies, Phil; McCarty, Sara; Hamberg, Kristina

    2017-06-01

    Background Topical antimicrobials, such as silver dressings, are progressively being used alongside systemic antibiotics to provide adjunctive, antimicrobial therapy to wounds that are clinically infected or at risk of infection. To help improve wound management, dressings that use Safetac soft silicone technology in combination with a silver-impregnated foam dressing material were developed by Mölnlycke Health Care (Gothenburg, Sweden). The range comprises Mepilex Ag, Mepilex Border Ag and Mepilex Transfer Ag. Aims A literature review was undertaken to identify and summarise clinical data from the entire evidence hierarchy, as well as data from in vitro tests, which support the use of silver-containing foam dressings with Safetac. Method The MEDLINE (National Library of Medicine, Bethesda, US) and EMBASE (Elsevier BV, Amsterdam, Netherlands) bibliographic databases were searched. In addition, abstract books and proceedings documents relating to national and international conferences were scanned in order to identify presentations (oral, e-poster and poster) of relevance to the review. Results In vitro test results showed that the silver-containing foam dressings with Safetac have both rapid and sustained activity against a range of wound pathogens, reducing planktonic and established biofilm cultures, and preventing biofilm formation. In numerous clinical studies, silvercontaining foam dressings with Safetac were used to manage wound bioburden effectively and resolve signs of localised infection in both acute wounds (such as surgical, traumatic and burn injuries) and chronic wounds (such as leg ulcers, pressure ulcers (PUs), diabetic foot ulcers (DFUs), and cancerous wounds). Studies reported that silver-containing foam dressings with Safetac are easy to use, provide an optimal environment for wound healing, and are associated with atraumatic and virtually painfree removal. As well as being clinically effective, they are reported to be cost-effective when used on wounds that require topical antimicrobial therapy. Conclusion The findings of both scientific and clinical studies clearly indicate that clinical, patient-related and economic benefits are associated with the use of Mepilex Ag, Mepilex Border Ag and Mepilex Transfer Ag with Safetac in the treatment of wounds where antimicrobial activity is needed to help manage bioburden.

  7. The effect of negative pressure wound therapy with antibacterial dressings or antiseptics on an in vitro wound model.

    PubMed

    Matiasek, J; Domig, K J; Djedovic, G; Babeluk, R; Assadian, O

    2017-05-02

    The aim of this study was to investigate the bacterial bioburden in experimental in vitro wounds during the application of conventional negative pressure wound therapy (NPWT), with and without antimicrobial dressings (polyhexanide, silver), against NPWT instillation of octenidine. Experimental wounds produced in an in vitro porcine wound model were homogenously contaminated with bacterial suspension and treated with NPWT and different options. Group A: non-antimicrobial polyurethane foam dressing; group B: antimicrobial polyurethane foam dressing containing silver; group C: antimicrobial gauze dressing containing polyhexanide; group D: non-antimicrobial polyurethane foam dressing intermittently irrigated with octenidine; group E: negative control (non-antimicrobial polyurethane foam dressing without NPWT). Standard biopsies were harvested after 24 and 28 hours. This study demonstrated that the use of NPWT with intermitted instillation of octenidine (group D) or application of silver-based polyurethane foam dressings (group B) is significantly superior against Staphylococcus aureus colonisation in experimental wounds compared with non-antimicrobial polyurethane foam dressing (group A) after 48 hours. Surprisingly, the polyhexanide-based dressing (group C) used in this model showed no statistical significant effect compared with the control group (group E) after 24 or 48 hours of treatment. Both intermitted instillation of octenidine and silver-based dressings in standard NPWT were significantly superior compared with non-antimicrobial polyurethane foam dressings or PHMB coated gauze dressing after 48 hours.

  8. Evaluation of a foam dressing for acute and chronic wound exudate management.

    PubMed

    Bullough, Lindsay; Johnson, Sue; Forder, Rebecca

    2015-09-01

    This article discusses the use of a foam dressing for exudate management in both chronic and acute wounds, such as surgical wounds, pressure ulcers, diabetic ulcers, trauma wounds, and leg ulcers. The primary objective of the study was to observe patients' wound progression in terms of wound size and the condition of the wound bed, when using this foam dressing as either a primary or secondary dressing. The outcome of the evaluation demonstrated that ActivHeal Foam Contact dressing effectively managed exudate. It was also observed that the dressing can assist in autolysis and support improvements in peri-wound status. Choosing an appropriate dressing to manage a wound is essential. Clinicians working in the NHS are under pressure to deliver good-quality clinical outcomes, and the ActivHeal Foam Contact dressing supports this outcome.

  9. A prospective, randomized clinical trial to assess the cost-effectiveness of a modern foam dressing versus a traditional saline gauze dressing in the treatment of stage II pressure ulcers.

    PubMed

    Payne, Wyatt G; Posnett, John; Alvarez, Oscar; Brown-Etris, Marie; Jameson, Gayle; Wolcott, Randall; Dharma, Hussein; Hartwell, Samantha; Ochs, Diane

    2009-02-01

    Modern dressings such as hydrocolloids, gels, and foams are typically more expensive than traditional dressings such as gauze. However, if modern dressings require fewer changes, the overall cost of treatment may be lower despite the higher initial purchase price. If healing rates are comparable or better, modern dressings also may be cost-effective. A 4-week, prospective, randomized clinical trial to assess differences in treatment costs and cost-effectiveness between a modern foam dressing and saline-soaked gauze was conducted among 36 patients (22 men, 14 women, mean age 72.8 years) with a Stage II pressure ulcer (mean duration 35 weeks) at five centers in the United States. Participants were randomized to treatment with a self-adhesive polyurethane foam (n = 20) or saline-soaked gauze dressing (n = 16). No difference in time to wound closure was observed (P = 0.817). Patients in the foam group had less frequent dressing changes (P <0.001). Total cost over the study period was lower by $466 per patient (P = 0.055) and spending on dressings was lower by $92 per patient in the foam group (P = 0.025). Cost per ulcer healed was lower by $1,517 and cost per ulcer-free day was lower by $80 for patients in the foam group. On the evidence of this study, the foam dressing is a more cost-effective treatment than saline-soaked gauze for the treatment of Stage II pressure ulcers.

  10. [Potentially toxic antibiotics concentrations after administration using impregnated dressing in a severe burned patient: A case report].

    PubMed

    Dupouey, Julien; Wiramus, Sandrine; Albanese, Jacques; Guilhaumou, Romain; Blin, Olivier

    2016-10-01

    Severe burned patients present high risk of skins infections, frequently due to Pseudomonas aeruginosa. Impregnated dressings with amikacin or colistin could be a good alternative to obtain effective concentration directly at the infected site. Therapeutic drug monitoring for these antibiotics is currently recommended after an intravenous administration to obtain effective and non-toxic plasmatic concentrations. However, data are lacking about systemic exposition and risk of toxicity after an administration with impregnated dressings. We report the case of a severe burned patient with cutaneous infection treated with amikacin and colistin impregnated dressings, for which plasmatic pharmacokinetic profiles were performed. Copyright © 2016 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.

  11. Electrochemical properties of a lithium-impregnated metal foam anode for thermal batteries

    NASA Astrophysics Data System (ADS)

    Choi, Yu-Song; Yu, Hye-Ryeon; Cheong, Hae-Won

    2015-02-01

    Lithium-impregnated metal foam anodes (LIMFAs) are fabricated and investigated. The LIMFAs are prepared by the impregnation of lithium into molten-salt-coated nickel metal foam. A single cell with the LIMFA exhibits a specific capacity of 3009 As g-1. For comparison, a single cell with a LiSi alloy anode is also discharged, demonstrating a specific capacity of 1050 As g-1. These significant improvements can be attributed to the large amount of lithium impregnated into the metal foam as well as the molten lithium holding capability of the foam. Due to their excellent electrochemical properties, LIMFAs are suitable for use in thermal batteries.

  12. Evaluation of the Efficacy of Highly Hydrophilic Polyurethane Foam Dressing in Treating a Diabetic Foot Ulcer.

    PubMed

    Jung, Jae-A; Yoo, Ki-Hyun; Han, Seung-Kyu; Dhong, Eun-Sang; Kim, Woo-Kyung

    2016-12-01

    To demonstrate the efficacy of a highly hydrophilic polyurethane foam dressing in the treatment of diabetic ulcers. Diabetic foot ulcers often pose a difficult treatment problem. Polyurethane foam dressings have been used worldwide to accelerate wound healing, but only a few clinical studies demonstrate the effect of foam dressing on the healing of diabetic ulcers. Medical records of 1342 patients with diabetic ulcers who were admitted and treated at the authors' institution were reviewed. A total of 208 patients met the study's inclusion criteria. Of these 208 patients, 137 were treated with a highly hydrophilic polyurethane foam dressing, and 71 were treated with saline gauze (control group). Except for the application of polyurethane foam dressing, the treatment method was identical for patients in both groups. The wound healing outcomes of the 2 groups were compared. Complete wound healing occurred in 87 patients (63.5%) in the polyurethane foam dressing group and in 28 patients (39.4%) in the control group within 12 weeks (P < .05, X test). The mean percentage of wound area reduction in both groups was statistically significant (P < .05, Mann-Whitney U test). The mean time required for complete closure in patients who achieved complete healing within 12 weeks was 6.2 (SD, 3.4) weeks and 7.3 (SD, 2.6) weeks in the polyurethane foam dressing and control groups, respectively (P < .05, Mann-Whitney U test). These results indicate that the highly hydrophilic polyurethane foam dressing may provide an effective treatment strategy for diabetic foot ulcers.

  13. A prospective comparison of a new, synthetic donor site dressing versus an impregnated gauze dressing.

    PubMed

    Hickerson, W L; Kealey, G P; Smith, D J; Thomson, P D

    1994-01-01

    Three institutions enrolled 38 patients who required bilateral skin graft donor sites into a safety and efficacy study of a new synthetic donor site dressing. Bilateral donor sites were randomized to receive either a new, synthetic donor site dressing or an impregnated gauze dressing. Wounds were assessed by time to healing, pain, and patient preference. Synthetic dressing wounds were treated 7.9 days compared with 10.2 days for gauze dressing wounds (p < 0.001), and synthetic dressing wounds were more completely epithelialized. Visual analogue pain analysis revealed significantly less donor site pain with synthetic dressing (2.94) versus gauze dressing (4.64) (p < 0.001). Synthetic dressing had fewer treatment-related adverse experiences than gauze dressing (2 vs 7) and was judged by recipients to be superior to gauze dressing in comfort, pain relief, cosmetic appeal, ease of ambulation, and overall acceptance.

  14. Foam dressings for treating pressure ulcers.

    PubMed

    Walker, Rachel M; Gillespie, Brigid M; Thalib, Lukman; Higgins, Niall S; Whitty, Jennifer A

    2017-10-12

    Pressure ulcers, also known as pressure injuries and bed sores, are localised areas of injury to the skin or underlying tissues, or both. Dressings made from a variety of materials, including foam, are used to treat pressure ulcers. An evidence-based overview of dressings for pressure ulcers is needed to enable informed decision-making on dressing use. This review is part of a suite of Cochrane Reviews investigating the use of dressings in the treatment of pressure ulcers. Each review will focus on a particular dressing type. To assess the clinical and cost effectiveness of foam wound dressings for healing pressure ulcers in people with an existing pressure ulcer in any care setting. In February 2017 we searched: the Cochrane Wounds Specialised Register; the Cochrane Central Register of Controlled Trials (CENTRAL); Ovid MEDLINE (including In-Process & Other Non-Indexed Citations); Ovid Embase; EBSCO CINAHL Plus and the NHS Economic Evaluation Database (NHS EED). We also searched clinical trials registries for ongoing and unpublished studies, and scanned reference lists of relevant included studies as well as reviews, meta-analyses and health technology reports to identify additional studies. There were no restrictions with respect to language, date of publication or study setting. Published or unpublished randomised controlled trials (RCTs) and cluster-RCTs, that compared the clinical and cost effectiveness of foam wound dressings for healing pressure ulcers (Category/Stage II or above). Two review authors independently performed study selection, risk of bias and data extraction. A third reviewer resolved discrepancies between the review authors. We included nine trials with a total of 483 participants, all of whom were adults (59 years or older) with an existing pressure ulcer Category/Stage II or above. All trials had two arms, which compared foam dressings with other dressings for treating pressure ulcers.The certainty of evidence ranged from low to very low due to various combinations of selection, performance, attrition, detection and reporting bias, and imprecision due to small sample sizes and wide confidence intervals. We had very little confidence in the estimate of effect of included studies. Where a foam dressing was compared with another foam dressing, we established that the true effect was likely to be substantially less than the study's estimated effect.We present data for four comparisons.One trial compared a silicone foam dressing with another (hydropolymer) foam dressing (38 participants), with an eight-week (short-term) follow-up. It was uncertain whether alternate types of foam dressing affected the incidence of healed pressure ulcers (RR 0.89, 95% CI 0.45 to 1.75) or adverse events (RR 0.37, 95% CI 0.04 to 3.25), as the certainty of evidence was very low, downgraded for serious limitations in study design and very serious imprecision.Four trials with a median sample size of 20 participants (230 participants), compared foam dressings with hydrocolloid dressings for eight weeks or less (short-term). It was uncertain whether foam dressings affected the probability of healing in comparison to hydrocolloid dressings over a short follow-up period in three trials (RR 0.85, 95% CI 0.54 to 1.34), very low-certainty evidence, downgraded for very serious study limitations and serious imprecision. It was uncertain if there was a difference in risk of adverse events between groups (RR 0.88, 95% CI 0.37 to 2.11), very low-certainty evidence, downgraded for serious study limitations and very serious imprecision. Reduction in ulcer size, patient satisfaction/acceptability, pain and cost effectiveness data were also reported but we assessed the evidence as being of very low certainty.One trial (34 participants), compared foam and hydrogel dressings over an eight-week (short-term) follow-up. It was uncertain if the foam dressing affected the probability of healing (RR 1.00, 95% CI 0.78 to 1.28), time to complete healing (MD 5.67 days 95% CI -4.03 to 15.37), adverse events (RR 0.33, 95% CI 0.01 to 7.65) or reduction in ulcer size (MD 0.30 cm 2 per day, 95% CI -0.15 to 0.75), as the certainty of the evidence was very low, downgraded for serious study limitations and very serious imprecision.The remaining three trials (181 participants) compared foam with basic wound contact dressings. Follow-up times ranged from short-term (8 weeks or less) to medium-term (8 to 24 weeks). It was uncertain whether foam dressings affected the probability of healing compared with basic wound contact dressings, in the short term (RR 1.33, 95% CI 0.62 to 2.88) or medium term (RR 1.17, 95% CI 0.79 to 1.72), or affected time to complete healing in the medium term (MD -35.80 days, 95% CI -56.77 to -14.83), or adverse events in the medium term (RR 0.58, 95% CI 0.33 to 1.05). This was due to the very low-certainty evidence, downgraded for serious to very serious study limitations and imprecision. Reduction in ulcer size, patient satisfaction/acceptability, pain and cost effectiveness data were also reported but again, we assessed the evidence as being of very low certainty.None of the included trials reported quality of life or pressure ulcer recurrence. It is uncertain whether foam dressings are more clinically effective, more acceptable to users, or more cost effective compared to alternative dressings in treating pressure ulcers. It was difficult to make accurate comparisons between foam dressings and other dressings due to the lack of data on reduction of wound size, complete wound healing, treatment costs, or insufficient time-frames. Quality of life and patient (or carer) acceptability/satisfaction associated with foam dressings were not systematically measured in any of the included studies. We assessed the certainty of the evidence in the included trials as low to very low. Clinicians need to carefully consider the lack of robust evidence in relation to the clinical and cost-effectiveness of foam dressings for treating pressure ulcers when making treatment decisions, particularly when considering the wound management properties that may be offered by each dressing type and the care context.

  15. OUTCOME OF FOAM VERSUS GAUZE DRESSINGS IN NEGATIVE PRESSURE WOUND THERAPY FOR THE MANAGEMENT OF ACUTE TRAUMATIC WOUNDS WITH SOFT TISSUE LOSS AT KENYATTA NATIONAL HOSPITAL.

    PubMed

    Ondieki, J G; Khainga, S O; Owilla, F; Nangole, F W

    2012-07-01

    Wounds have provided a challenge to the clinicians for centuries and this scenario persists to the 21st century. Negative pressure wound therapy (NPWT) is one of the latest additions in wound management. It has been widely adopted in developed countries with foam as the default wound dressing although it has some limitations. To determine the difference in outcomes between the use of gauze versus foam as wound dressing in NPWT for the management of acute traumatic wounds with soft tissue loss. Prospective randomised comparative interventional study. Kenyatta National Hospital Orthopaedic and Surgical wards. All patients aged above 12 years with Class III and Class IV acute traumatic wounds. The main outcome measure is the time taken to achieve 100% wound granulation. Comparisons were also made on the mean pain scores during dressing change and the percentage change in wound surface area. Wounds took an average of 8.4 days in the gauze group and 8.1 days in the foam group (p = 0.698) to achieve full granulation. The percentage change in wound surface area was 5.3 versus 5.5 (P = 0.769) in the gauze and foam groups respectively. The infection rates were comparable between the two groups (28% for gauze and 23.1% for foam, p = 0.697) and there was no significant difference in the median pain scores (gauze = 4.5, foam = 4.8 with p = 0.174). However, outcomes with gauze dressing were influenced significantly by the time to application of NPWT, initial wound surface area and wound infection while with foam dressing outcomes tended to be affected less so by the above factors. In the use of NPWT for the management of acute traumatic wounds, there is no difference in terms of time to full wound granulation, change in wound surface area, wound infection and pain during dressing change whether gauze or foam is used as the wound dressing material.

  16. Analysis of the Pressure Distribution Qualities of a Silicone Border Foam Dressing.

    PubMed

    Miller, Stephannie K; Sharma, Neal; Aberegg, Lauren C; Blasiole, Kimberly N; Fulton, Judith A

    2015-01-01

    To determine whether application of a silicone foam dressing is associated with decreased interface pressures when applied to the heel. Prospective, within-subjects design. The study was conducted in a community-based hospital using a convenience sample of 50 healthy volunteers with a mean age of 39.6 years and mean body mass index of 26.6; 70% were female. Application of the silicone border foam dressing was randomized between the left and right heels. Participants were asked to lie down in the supine position on a viscoelastic foam mattress. Interface pressure measurements were captured using a pressure mapping system; measurements were taken once with the dressing applied to the heel (intervention map) and once without (control map). Data were captured after a 4-minute time period allowing stabilization. Analysis was based on mean interface pressure; data points were collected for both heels in each of the 2 frames, yielding 4 observations per subject. Application of the dressing was associated with a significant decrease in average pressure measurements as compared to the heel with no dressing applied (P < .001). Application of the dressing did not impact pressure readings for the heel to which no dressing was applied (P = .53), and application of the dressing to either the left or right heel did not impact pressure readings (ie, the random effect was insignificant; P = .9). Application of a silicone border foam dressing is associated with significant reduction in interface pressure and may be considered as part of a pressure ulcer prevention program.

  17. Removal of adhesive wound dressing and its effects on the stratum corneum of the skin: comparison of eight different adhesive wound dressings.

    PubMed

    Matsumura, Hajime; Imai, Ryutaro; Ahmatjan, Niyaz; Ida, Yukiko; Gondo, Masahide; Shibata, Dai; Wanatabe, Katsueki

    2014-02-01

    In recent years, adhesive wound dressings have been increasingly applied postoperatively because of their ease of use as they can be kept in place without having to cut and apply surgical tapes and they can cover a wound securely. However, if a wound dressing strongly adheres to the wound, a large amount of stratum corneum is removed from the newly formed epithelium or healthy periwound skin. Various types of adhesives are used on adhesive wound dressings and the extent of skin damage depends on how much an adhesive sticks to the wound or skin surface. We quantitatively determined and compared the amount of stratum corneum removed by eight different wound dressings including polyurethane foam using acrylic adhesive, silicone-based adhesive dressing, composite hydrocolloid and self-adhesive polyurethane foam in healthy volunteers. The results showed that wound dressings with silicone adhesive and self-adhesive polyurethane foam removed less stratum corneum, whereas composite hydrocolloid and polyurethane foam using acrylic adhesive removed more stratum corneum. © 2012 The Authors. International Wound Journal © 2012 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  18. Application of a drainage film reduces fibroblast ingrowth into large-pored polyurethane foam during negative-pressure wound therapy in an in vitro model.

    PubMed

    Wiegand, Cornelia; Springer, Steffen; Abel, Martin; Wesarg, Falko; Ruth, Peter; Hipler, Uta-Christina

    2013-01-01

    Negative-pressure wound therapy (NPWT) is an advantageous treatment option in wound management to promote healing and reduce the risk of complications. NPWT is mainly carried out using open-cell polyurethane (PU) foams that stimulate granulation tissue formation. However, growth of wound bed tissue into foam material, leading to disruption of newly formed tissue upon dressing removal, has been observed. Consequently, it would be of clinical interest to preserve the positive effects of open-cell PU foams while avoiding cellular ingrowth. The study presented analyzed effects of NPWT using large-pored PU foam, fine-pored PU foam, and the combination of large-pored foam with drainage film on human dermal fibroblasts grown in a collagen matrix. The results showed no difference between the dressings in stimulating cellular migration during NPWT. However, when NPWT was applied using a large-pored PU foam, the fibroblasts continued to migrate into the dressing. This led to significant breaches in the cell layers upon removal of the samples after vacuum treatment. In contrast, cell migration stopped at the collagen matrix edge when fine-pored PU foam was used, as well as with the combination of PU foam and drainage film. In conclusion, placing a drainage film between collagen matrix and the large-pored PU foam dressing reduced the ingrowth of cells into the foam significantly. Moreover, positive effects on cellular migration were not affected, and the effect of the foam on tissue surface roughness in vitro was also reduced. © 2013 by the Wound Healing Society.

  19. Effectiveness and Value of Prophylactic 5-Layer Foam Sacral Dressings to Prevent Hospital-Acquired Pressure Injuries in Acute Care Hospitals: An Observational Cohort Study.

    PubMed

    Padula, William V

    The purpose of this study was to examine the effectiveness and value of prophylactic 5-layer foam sacral dressings to prevent hospital-acquired pressure injury rates in acute care settings. Retrospective observational cohort. We reviewed records of adult patients 18 years or older who were hospitalized at least 5 days across 38 acute care hospitals of the University Health System Consortium (UHC) and had a pressure injury as identified by Patient Safety Indicator #3 (PSI-03). All facilities are located in the United States. We collected longitudinal data pertaining to prophylactic 5-layer foam sacral dressings purchased by hospital-quarter for 38 academic medical centers between 2010 and 2015. Longitudinal data on acute care, hospital-level patient outcomes (eg, admissions and PSI-03 and pressure injury rate) were queried through the UHC clinical database/resource manager from the Johns Hopkins Medicine portal. Data on volumes of dressings purchased per UHC hospital were merged with UHC data. Mixed-effects negative binomial regression was used to test the longitudinal association of prophylactic foam sacral dressings on pressure injury rates, adjusted for hospital case-mix and Medicare payments rules. Significant pressure injury rate reductions in US acute care hospitals between 2010 and 2015 were associated with the adoption of prophylactic 5-layer foam sacral dressings within a prevention protocol (-1.0 cases/quarter; P = .002) and changes to Medicare payment rules in 2014 (-1.13 cases/quarter; P = .035). Prophylactic 5-layer foam sacral dressings are an effective component of a pressure injury prevention protocol. Hospitals adopting these technologies should expect good value for use of these products.

  20. Effectiveness and Value of Prophylactic 5-Layer Foam Sacral Dressings to Prevent Hospital-Acquired Pressure Injuries in Acute Care Hospitals

    PubMed Central

    2017-01-01

    PURPOSE: The purpose of this study was to examine the effectiveness and value of prophylactic 5-layer foam sacral dressings to prevent hospital-acquired pressure injury rates in acute care settings. DESIGN: Retrospective observational cohort. SAMPLE AND SETTING: We reviewed records of adult patients 18 years or older who were hospitalized at least 5 days across 38 acute care hospitals of the University Health System Consortium (UHC) and had a pressure injury as identified by Patient Safety Indicator #3 (PSI-03). All facilities are located in the United States. METHODS: We collected longitudinal data pertaining to prophylactic 5-layer foam sacral dressings purchased by hospital-quarter for 38 academic medical centers between 2010 and 2015. Longitudinal data on acute care, hospital-level patient outcomes (eg, admissions and PSI-03 and pressure injury rate) were queried through the UHC clinical database/resource manager from the Johns Hopkins Medicine portal. Data on volumes of dressings purchased per UHC hospital were merged with UHC data. Mixed-effects negative binomial regression was used to test the longitudinal association of prophylactic foam sacral dressings on pressure injury rates, adjusted for hospital case-mix and Medicare payments rules. RESULTS: Significant pressure injury rate reductions in US acute care hospitals between 2010 and 2015 were associated with the adoption of prophylactic 5-layer foam sacral dressings within a prevention protocol (−1.0 cases/quarter; P = .002) and changes to Medicare payment rules in 2014 (−1.13 cases/quarter; P = .035). CONCLUSIONS: Prophylactic 5-layer foam sacral dressings are an effective component of a pressure injury prevention protocol. Hospitals adopting these technologies should expect good value for use of these products. PMID:28816929

  1. Comprehensive In Situ Killing of Six Common Wound Pathogens With Manuka Honey Dressings Using a Modified AATCC-TM100.

    PubMed

    Watson, Denis; Bergquist, Stephen; Nicholson, Julie; Norrie, David H

    2017-06-28

    While Manuka honey in vitro is strongly antimicrobial, there have been, to the best of the authors' knowledge, no studies showing that dressings impregnated with Manuka honey can kill organisms in the dressing itself. The investigators used the American Association of Textile Chemists and Colorists' 100 test methodology to compare honey-impregnated dressings with control dressings (without honey) on the ability to kill common wound pathogens. Organisms were chosen after a review of the causal organisms found in actual wound infections over a 12-month period in a busy outpatient wound clinic. Even when the dressings were challenged daily with further inoculated organisms, > 5-log reductions were routinely noted across a range of pathogens, including multiple drug-resistant species using dressings containing Manuka honey relative to the control. The results presented herein show that when well-characterized medical-grade Manuka honey is used in dressings (ie, a minimum of 400 mg methylglyoxal/kg) these dressings can comprehensively kill common wound pathogens associated with infected wounds.

  2. Low density microcellular carbon or catalytically impregnated carbon foams and process for their prepartion

    DOEpatents

    Hopper, Robert W.; Pekala, Richard W.

    1988-01-01

    Machinable and structurally stable, low density microcellular carbon, and catalytically impregnated carbon, foams, and process for their preparation, are provided. Pulverized sodium chloride is classified to improve particle size uniformity, and the classified particles may be further mixed with a catalyst material. The particles are cold pressed into a compact having internal pores, and then sintered. The sintered compact is immersed and then submerged in a phenolic polymer solution to uniformly fill the pores of the compact with phenolic polymer. The compact is then heated to pyrolyze the phenolic polymer into carbon in the form of a foam. Then the sodium chloride of the compact is leached away with water, and the remaining product is freeze dried to provide the carbon, or catalytically impregnated carbon, foam.

  3. Low density microcellular carbon or catalytically impregnated carbon foams and process for their preparation

    DOEpatents

    Hooper, R.W.; Pekala, R.W.

    1987-04-30

    Machinable and structurally stable, low density microcellular carbon, and catalytically impregnated carbon, foams, and process for their preparation, are provided. Pulverized sodium chloride is classified to improve particle size uniformity, and the classified particles may be further mixed with a catalyst material. The particles are cold pressed into a compact having internal pores, and then sintered. The sintered compact is immersed and then submerged in a phenolic polymer solution to uniformly fill the pores of the compact with phenolic polymer. The compact is then heated to pyrolyze the phenolic polymer into carbon in the form of a foam. Then the sodium chloride of the compact is leached away with water, and the remaining product is freeze dried to provide the carbon, or catalytically impregnated carbon, foam.

  4. Clinical effectiveness of a silicone foam dressing for the prevention of heel pressure ulcers in critically ill patients: Border II Trial.

    PubMed

    Santamaria, N; Gerdtz, M; Liu, W; Rakis, S; Sage, S; Ng, A W; Tudor, H; McCann, J; Vassiliou, T; Morrow, F; Smith, K; Knott, J; Liew, D

    2015-08-01

    Critically ill patients are at high risk of developing pressure ulcers (PU), with the sacrum and heels being highly susceptible to pressure injuries. The objective of our study was to evaluate the clinical effectiveness of a new multi-layer, self-adhesive soft silicone foam heel dressing to prevent PU development in trauma and critically ill patients in the intensive care unit (ICU). A cohort of critically ill patients were enrolled at the Royal Melbourne Hospital. Each patient had the multi-layer soft silicone foam dressing applied to each heel on admission to the emergency department. The dressings were retained with a tubular bandage for the duration of the patients' stay in the ICU. The skin under the dressings was examined daily and the dressings were replaced every three days. The comparator for our cohort study was the control group from the recently completed Border Trial. Of the 191 patients in the initial cohort, excluding deaths, loss to follow-up and transfers to another ward, 150 patients were included in the final analysis. There was no difference in key demographic or physiological variables between the cohorts, apart from a longer ICU length of stay for our current cohort. No PUs developed in any of our intervention cohort patients compared with 14 patients in the control cohort (n=152; p<0.001) who developed a total of 19 heel PUs. We conclude, based on our results, that the multi-layer soft silicone foam dressing under investigation was clinically effective in reducing ICU-acquired heel PUs. The findings also support previous research on the clinical effectiveness of multi-layer soft silicone foam dressings for PU prevention in the ICU.

  5. Randomized controlled trial of chlorhexidine dressing and highly adhesive dressing for preventing catheter-related infections in critically ill adults.

    PubMed

    Timsit, Jean-François; Mimoz, Olivier; Mourvillier, Bruno; Souweine, Bertrand; Garrouste-Orgeas, Maïté; Alfandari, Serge; Plantefeve, Gaétan; Bronchard, Régis; Troche, Gilles; Gauzit, Remy; Antona, Marion; Canet, Emmanuel; Bohe, Julien; Lepape, Alain; Vesin, Aurélien; Arrault, Xavier; Schwebel, Carole; Adrie, Christophe; Zahar, Jean-Ralph; Ruckly, Stéphane; Tournegros, Caroline; Lucet, Jean-Christophe

    2012-12-15

    Most vascular catheter-related infections (CRIs) occur extraluminally in patients in the intensive care unit (ICU). Chlorhexidine-impregnated and strongly adherent dressings may decrease catheter colonization and CRI rates. To determine if chlorhexidine-impregnated and strongly adherent dressings decrease catheter colonization and CRI rates. In a 2:1:1 assessor-masked randomized trial in patients with vascular catheters inserted for an expected duration of 48 hours or more in 12 French ICUs, we compared chlorhexidine dressings, highly adhesive dressings, and standard dressings from May 2010 to July 2011. Coprimary endpoints were major CRI with or without catheter-related bloodstream infection (CR-BSI) with chlorhexidine versus nonchlorhexidine dressings and catheter colonization rate with highly adhesive nonchlorhexidine versus standard nonchlorhexidine dressings. Catheter-colonization, CR-BSIs, and skin reactions were secondary endpoints. A total of 1,879 patients (4,163 catheters and 34,339 catheter-days) were evaluated. With chlorhexidine dressings, the major-CRI rate was 67% lower (0.7 per 1,000 vs. 2.1 per 1,000 catheter-days; hazard ratio [HR], 0.328; 95% confidence interval [CI], 0.174-0.619; P = 0.0006) and the CR-BSI rate 60% lower (0.5 per 1,000 vs. 1.3 per 1,000 catheter-days; HR, 0.402; 95% CI, 0.186-0.868; P = 0.02) than with nonchlorhexidine dressings; decreases were noted in catheter colonization and skin colonization rates at catheter removal. The contact dermatitis rate was 1.1% with and 0.29% without chlorhexidine. Highly adhesive dressings decreased the detachment rate to 64.3% versus 71.9% (P < 0.0001) and the number of dressings per catheter to two (one to four) versus three (one to five) (P < 0.0001) but increased skin colonization (P < 0.0001) and catheter colonization (HR, 1.650; 95% CI, 1.21-2.26; P = 0.0016) without influencing CRI or CR-BSI rates. A large randomized trial demonstrated that chlorhexidine-gel-impregnated dressings decreased the CRI rate in patients in the ICU with intravascular catheters. Highly adhesive dressings decreased dressing detachment but increased skin and catheter colonization. Clinical trial registered with www.clinicaltrials.gov (NCT 01189682).

  6. Do Prophylactic Foam Dressings Reduce Heel Pressure Injuries?

    PubMed

    Ramundo, Janet; Pike, Catlin; Pittman, Joyce

    The purpose of this evidence-based report card is to examine the evidence and provide recommendations related to the effectiveness of prophylactic foam dressings in reducing heel pressure injuries. Do prophylactic foam dressings applied to the heel reduce heel pressure injuries for patients in the acute care setting? A search of the literature was performed by a trained university librarian that resulted in 56 articles that examined pressure injury, prevention, and prophylactic dressings. A systematic approach was used to review titles, abstracts, and text, yielding 13 studies that met inclusion criteria. Strength of the evidence was rated based on the methodology from Essential Evidence Plus: Levels of Evidence and Oxford Center for Evidence-Based Medicine. Thirteen studies were identified that met inclusion criteria; 1 was a randomized controlled trial, 2 were systematic reviews, 3 quasi-experimental cohort studies, 1 quality improvement study, 1 case series, 1 scoping review, 1 consensus panel, and 3 bench studies. All of the studies identified suggest that the use of prophylactic foam dressings reduces the development of pressure injuries on the heel when used in conjunction with a pressure injury prevention program. The strength of the evidence for the identified studies was level 1 (4 level A, 4 level B, and 5 level C). The use of prophylactic multilayer foam dressings applied to the heels, in conjunction with an evidence-based pressure injury prevention program, is recommended for prevention of pressure injuries on the heel (SORT level 1).

  7. A Randomized, Controlled Clinical Trial of Honey-Impregnated Dressing for Treating Diabetic Foot Ulcer.

    PubMed

    Imran, Muhammad; Hussain, Muhammad Barkaat; Baig, Mukhtiar

    2015-10-01

    To investigate the effect of Beri-honey-impregnated dressing on diabetic foot ulcer and compare it with normal saline dressing. A randomized, controlled trial. Sughra Shafi Medical Complex, Narowal, Pakistan and Bhatti International Trust (BIT) Hospital, Affiliated with Central Park Medical College, Lahore, from February 2006 to February 2010. Patients with Wagner's grade 1 and 2 ulcers were enrolled. Those patients were divided in two groups; group A (n=179) treated with honey dressing and group B (n=169) treated with normal saline dressing. Outcome measures were calculated in terms of proportion of wounds completely healed (primary outcome), wound healing time, and deterioration of wounds. Patients were followed-up for a maximum of 120 days. One hundred and thirty six wounds (75.97%) out of 179 were completely healed with honey dressing and 97 (57.39%) out of 169 wtih saline dressing (p=0.001). The median wound healing time was 18.00 (6 - 120) days (Median with IQR) in group A and 29.00 (7 - 120) days (Median with IQR) in group B (p < 0.001). The present results showed that honey is an effective dressing agent instead of conventional dressings, in treating patients of diabetic foot ulcer.

  8. Role of multi-layer foam dressings with Safetac in the prevention of pressure ulcers: a review of the clinical and scientific data.

    PubMed

    Davies, Phil

    2016-01-01

    Despite the implementation of prevention strategies, pressure ulcers (PUs) continue to be a challenging health problem for patients (and their carers), clinicians and health-care providers. One area of growing interest is the use of prophylactic dressings (which were originally designed for the treatment of PUs and other wound types) as a component of standard prevention measures. Over the past few years, a large amount of scientific and clinical data relating to this subject has been published in peer-reviewed journals and presented at international meetings and conferences. A substantial proportion of these data relate to one group of dressings: multi-layer foam dressings with Safetac, which are manufactured by Mölnlycke Health Care (Gothenburg, Sweden). This evidence pool has influenced the experts involved in updating the Clinical Practice Guideline, produced by the National Pressure Ulcer Advisory Panel, European Pressure Ulcer Advisory Panel and Pan Pacific Pressure Injury Alliance, on the prevention and treatment of PUs. The updated Guideline, published in 2014, recommends that, as part of their PU prevention regimens, clinicians should consider applying prophylactic dressings to bony prominences in anatomical areas that are frequently subjected to friction and shear. A literature review was undertaken to identify clinical data from the entire evidence hierarchy, as well as scientific data from laboratory studies, on the use of multi-layer foam dressings with Safetac in the prevention of pressure ulceration. The MEDLINE (National Library of Medicine, Bethesda, US) and EMBASE (Elsevier B, Amsterdam, Netherlands) bibliographic databases were searched. In addition, abstract books and proceedings documents relating to national and international conferences were scanned in order to identify presentations (i.e. oral, e-posters and posters) of relevance to the review. Clinical and health economic experts have undertaken numerous studies, including randomised controlled trials, to assess the efficacy and cost-effectiveness of using multi-layer foam dressings with Safetac as a component of standard PU prevention strategies. The results of these studies indicate that the application of multi-layer foam dressings containing Safetac can reduce the occurrence of PUs on anatomical locations such as the sacrum and the heel, and underneath medical devices. Scientists have also developed and used laboratory methods to gain a better understanding of how prophylactic dressings work. The results of these studies indicate that the composition of foam dressings containing Safetac (i.e. their multi-layer structure) sets them apart from other dressings due to their ability to mediate the effects of physical forces (i.e. pressure, friction and shear) and control microclimate, all of which contribute to pressure ulceration. The evidence pool clearly indicates that the prophylactic use of multi-layer foam dressings with Safetac as a component of standard prevention measures is beneficial to the clinician, the health-care provider and the patient. It should be noted that the findings outlined in this review may not be transferable to other products as their makeup and components are likely to differ significantly from those of multi-layer foam dressings with Safetac. As the importance of evidence-based practice and the need for cost-effective care continues to grow, clinicians and provider should carefully consider this point when selecting prophylactic dressings for PU prevention.

  9. Randomized clinical trial to compare negative-pressure wound therapy approaches with low and high pressure, silicone-coated dressing, and polyurethane foam dressing.

    PubMed

    Lavery, Lawrence A; La Fontaine, Javier; Thakral, Gaurav; Kim, Paul J; Bhavan, Kavita; Davis, Kathryn E

    2014-03-01

    This study was designed to compare two approaches to negative-pressure wound therapy: 125-mmHg pressure with a polyurethane foam dressing and 75-mmHg pressure with a silicone-coated dressing. Forty patients with diabetic foot wounds, after incision and drainage or amputation for infection, were assigned randomly to negative-pressure wound therapy with 75-mmHg continuous pressure with a silicone-covered dressing (75-mmHg group) or 125-mmHg with a polyurethane foam dressing (125-mmHg group) for up to 4 weeks or until surgical closure. There was no difference in the proportion of wounds that were closed surgically (75-mmHg group, 50 percent; 125-mmHg group, 60 percent), wounds that demonstrated 50 percent wound area reduction (75-mmHg group, 65 percent; 125-mmHg group, 80 percent), or wounds that demonstrated 50 percent wound volume reduction after 4 weeks of therapy (75-mmHg group, 95 percent; 125-mmHg group, 90 percent). The authors' results suggest that there was no difference in outcomes in wounds treated with low pressure (75 mmHg) with a silicone-coated interface and high pressure (125 mmHg) with a polyurethane foam interface. Therapeutic, II.

  10. Evaluation of a honey-impregnated tulle dressing in primary care.

    PubMed

    Stephen-Haynes, Jackie

    2004-06-01

    Honey has been used for its healing properties for centuries and has been used to dress wounds with favourable results. The emergence of antibiotic resistance and growing interest in "natural" or "complementary" therapies has led to an interest in honey dressings. Much of the research to date has been related to honey's antibacterial properties. However, the healing properties claimed for honey also include stimulating new tissue growth, moist wound healing, fluid handling and promoting epithelialization. Until recently, honey had not been developed as a wound management product and was not a certified pharmaceutical device. Activon Tulle is a sterile, non-adherent dressing impregnated with Leptospermum scoparium hone. The claimed properties of honey dressings would make this a valuable addition to the dressing currently available in the primary care setting. An evaluation was undertaken involving 20 patients with a variety of wounds. A conclusion is drawn that while further research is needed, medical grade honey does appear to be a valuable addition to the wound management formulary.

  11. Managing burn wounds with SMARTPORE Technology polyurethane foam: two case reports.

    PubMed

    Imran, Farrah-Hani; Karim, Rahamah; Maat, Noor Hidayah

    2016-05-12

    Successful wound healing depends on various factors, including exudate control, prevention of microbial contaminants, and moisture balance. We report two cases of managing burn wounds with SMARTPORE Technology polyurethane foam dressing. In Case 1, a 2-year-old Asian girl presented with a delayed (11 days) wound on her right leg. She sustained a thermal injury from a hot iron that was left idle on the floor. Clinical inspection revealed an infected wound with overlying eschar that traversed her knee joint. As her parents refused surgical debridement under general anesthesia, hydrotherapy and wound dressing using SMARTPORE Technology Polyurethane foam were used. Despite the delay in presentation of this linear thermal pediatric burn injury that crossed the knee joint, the patient's response to treatment and its outcome were highly encouraging. She was cooperative and tolerated each dressing change without the need of supplemental analgesia. Her wound was healed by 24 days post-admission. In Case 2, a 25-year-old Asian man presented with a mixed thickness thermal flame burn on his left leg. On examination, the injury was a mix of deep and superficial partial thickness burn, comprising approximately 3% of his total body surface area. SMARTPORE Technology polyurethane foam was used on his wound; his response to the treatment was very encouraging as the dressing facilitated physiotherapy and mobility. The patient rated the pain during dressing change as 2 on a scale of 10 and his pain score remained the same in every subsequent change. His wound showed evidence of epithelialization by day 7 post-burn. There were no adverse events reported. Managing burn wounds with SMARTPORE Technology polyurethane foam resulted in reduced pain during dressing changes and the successful healing of partial and mixed thickness wounds. The use of SMARTPORE Technology polyurethane foam dressings showed encouraging results and requires further research as a desirable management option in burn wounds.

  12. Dressed for success? Silver impregnated nanocrystalline dressing for initial treatment of giant omphalocele.

    PubMed

    Percy, Dean B; Haddock, Candace; Ma, Vivian; Nowak, Amie; Panczuk, Julia; Butterworth, Sonia

    2018-05-01

    The purpose of this study was to describe outcomes and resource utilization in patients treated with twice-weekly silver impregnated (SI) nanocrystalline dressings for initial non-operative management of giant omphalocele (GO). A retrospective review of patients with GO treated with SI dressings was undertaken. Clinical parameters, cost, and complications were recorded. Five patients with GO were treated with SI dressings between 2014 and 2016. Clinical characteristic (mean ± SD) included gestational age 36 ± 4 weeks, birth weight 2.6 ± 0.63 kg, GO size 10.2 ± 4.7 cm, ventilator days 7.5 ± 8.7 d, days in NICU 41 ± 20 d, days to full feeds, 30 ± 15 d, and LOS 62 ± 41 d. The average in-hospital cost of SI dressings was $110 CAD/week. This is comparable to daily silver sulfadiazine dressings ($109CAD/week) which were used historically. All patients were discharged with once- or twice-weekly dressing changes. No ruptures occurred. There was one mortality secondary to pulmonary sepsis. For initial non-operative management of GO, twice weekly SI nanocrystalline dressings is safe and effective. Use of SI dressings results in decreased handling of infants, reduced physician and nursing resource utilization, and favourable outcomes. IV (Retrospective Case Series). Copyright © 2018. Published by Elsevier Inc.

  13. A study on the ability of quaternary ammonium groups attached to a polyurethane foam wound dressing to inhibit bacterial attachment and biofilm formation.

    PubMed

    Tran, Phat L; Hamood, Abdul N; de Souza, Anselm; Schultz, Gregory; Liesenfeld, Bernd; Mehta, Dilip; Reid, Ted W

    2015-01-01

    Bacterial infection of acute and chronic wounds impedes wound healing significantly. Part of this impediment is the ability of bacterial pathogens to grow in wound dressings. In this study, we examined the effectiveness of a polyurethane (PU) foam wound dressings coated with poly diallyl-dimethylammonium chloride (pDADMAC-PU) to inhibit the growth and biofilm development by three main wound pathogens, Staphylococcus aureus, Pseudomonas aeruginosa, and Acinetobacter baumannii, within the wound dressing. pDADMAC-PU inhibited the growth of all three pathogens. Time-kill curves were conducted both with and without serum to determine the killing kinetic of pDADMAC-PU. pDADMAC-PU killed S. aureus, A. baumannii, and P. aeruginosa. The effect of pDADMAC-PU on biofilm development was analyzed quantitatively and qualitatively. Quantitative analysis, colony-forming unit assay, revealed that pDADMAC-PU dressing produced more than eight log reduction in biofilm formation by each pathogen. Visualization of the biofilms by either confocal laser scanning microscopy or scanning electron microscopy confirmed these findings. In addition, it was found that the pDADMAC-PU-treated foam totally inhibited migration of bacteria through the foam for all three bacterial strains. These results suggest that pDADMAC-PU is an effective wound dressing that inhibits the growth of wound pathogens both within the wound and in the wound dressing. © 2014 by the Wound Healing Society.

  14. The Effect of Electrical Stimulation Combined with Foam Dressing on Ulcer Healing in Rats with Spinal Cord Injury.

    PubMed

    Yu, Ki-Pi; Yoo, Seol Bong; Yang, Seok Jeong; Yoon, Yong-Soon

    2015-11-01

    To evaluate the effect of electrical stimulation (ES) combined with foam dressing on wound healing in rats with spinal cord injury. Complete spinal cord injury was induced in 49 male Sprague-Dawley rats at the T11-L1 level, after which a pressure ulcer was induced on the left thigh. The newly invented surface electrode, which was fitted with foam inside, was applied to the ulcers. Rats were divided into 2 groups as follows: the ES group, which received foam dressings and ES (2 Hz and 200-microsecond duration, 15 mA) for 4 times a day, 30 minutes each, for 3 weeks; and the control group, which received the foam dressings without ES. The ulcer area was measured by taking a photograph daily from day 0 to day 21. Histopathologic and immune-histochemical evaluations were performed on day 1 and days 7, 14, and 21. The area of the ulcers of the ES group was smaller than that of the control group after day 14 (P < .05). In the ES group, the vascularity was significantly greater on day 14 and more decreased on day 21 compared with day 7 than that in the control group (P < .05). In the ES group, the area of positive reaction to anti-α-SMA antibody was increased compared with the control group on days 7 and 14 and decreased on day 21 (P > .05). Electrical stimulation combined with foam dressing by means of newly invented surface electrodes facilitates and accelerates the wound-healing process.

  15. A comparison of the in vitro moisture vapour transmission rate and in vivo fluid-handling capacity of six adhesive foam dressings to a newly reformulated adhesive foam dressing.

    PubMed

    Zehrer, Cindy L; Holm, David; Solfest, Staci E; Walters, Shelley-Ann

    2014-12-01

    This study compared moisture vapour transmission rate (MVTR) and wear time or fluid-handling capacities of six adhesive foam dressings to a reformulated control dressing. Standardised in vitro MVTR methodology and a previously published in vivo artificial wound model (AWM) were used. Mean inverted MVTR for the reformulated dressing was 12 750 g/m(2) /24 hours and was significantly higher than four of the six comparator dressings (P < 0·0001), which ranged from 830 to 11 360 g/m(2) /24 hours. Mean upright MVTR for the reformulated dressing was 980 g/m(2) /24 hours and was significantly different than all of the comparator dressings (P < 0·0001), which ranged from 80 to 1620 g/m(2) /24 hours (three higher/three lower). The reformulated dressing median wear time ranged from 6·1 to >7·0 days, compared with 1·0 to 3·5 days for the comparator dressings (P = 0·0012 to P < 0·0001). The median fluid volume handled ranged from 78·0 to >87 ml compared with 13·0 to 44·5 ml for the comparator dressings (P = 0·0007 to P < 0·001). Interestingly, inverted MVTR did not correspond well to the AWM. These results suggest that marked differences exist between the dressings in terms of both MVTR and wear time or fluid-handling capacity. Furthermore, high inverted MVTR does not necessarily predict longer wear time or fluid-handling capacities of absorbent dressings. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  16. Antimicrobial-impregnated dressing combined with negative-pressure wound therapy increases split-thickness skin graft engraftment: a simple effective technique.

    PubMed

    Wu, Cheng-Chun; Chew, Khong-Yik; Chen, Chien-Chang; Kuo, Yur-Ren

    2015-01-01

    Immobilization and adequate surface contact to wounds are critical for skin graft take. Techniques such as the tie-over dressing, cotton bolster, and vacuum-assisted closure are used to address this, but each has its limitations. This study is designed to assess the effect of antimicrobial-impregnated dressing (AMD) combined with negative-pressure wound therapy (NPWT) on skin graft survival. Retrospective case-control study : Patients with chronic or contaminated wounds treated with split-thickness skin graft. A broad spectrum of wounds was included, from causes such as trauma, burns, chronic diabetic ulcers, and infection. Antimicrobial-impregnated dressing, which contains 0.2% polyhexamethylene biguanide, with NPWT MAIN OUTCOME MEASURE:: Success of skin graft : In the AMD group, all skin grafts achieved 100% take without secondary intervention. No infection or graft failure was observed in any patients, and no complications, such as hematoma or seroma formation, were noted, although in the control group partial loss of skin grafts was noted in 3 patients. Infection and inadequate immobilization were thought to be the main reasons. There were no hematoma or seroma formations in the control group. Use of an AMD dressing with NPWT after split-thickness skin grafting can be an effective method to ensure good graft to wound contact and enhances skin graft take in chronic and contaminated wounds.

  17. Treatment of pressure sores in spina bifida patients with calcium alginate and foam dressings.

    PubMed

    Ausili, E; Paolucci, V; Triarico, S; Maestrini, C; Murolo, D; Focarelli, B; Rendeli, C

    2013-06-01

    Prospective study on local treatment of pressure sores using calcium alginate and foam dressings in spina bifida patients. Investigate if this sequential approach is valid and safe for selected patients with neurological impairments. Using European Pressure Ulcer Grading System, after clinical evaluation of local sore, selected patients of Spina Bifida Center of Rome were treated with sequential calcium alginate and foam dressings for 12 weeks. Pressure ulcere surfaces were measured monthly by ulcer tracing. The endpoints were the mean absolute areas surface reduction during every month and number of patients achieving a 50% or more during study. 14 patients (7 males aged 12-24 years) with spina bifida and pressure sores were treated. Mean and standard deviation of mean surface area reduction were 12.5 ± 7.5 cm 2 at start of the study versus 3.7 ± 5.2 cm 2 after 12 weeks, p < 0.001. 75% of the patients reached mean surface area reduction of 50% during trial. Dressing tolerance was good in every patient. Calcium alginate and foam dressings are valid and safe approach in the treatment of pressure sores in selected patients with spina bifida. In fact, they protect the wound and create an environment favorable to healing.

  18. Low density microcellular carbon or catalytically impregnated carbon forms and process for their preparation

    DOEpatents

    Hopper, Robert W.; Pekala, Richard W.

    1989-01-01

    Machinable and structurally stable, low density microcellular carbon, and catalytically impregnated carbon, foams, and process for their preparation, are provided. Pulverized sodium chloride is classified to improve particle size uniformity, and the classified particles may be further mixed with a catalyst material. The particles are cold pressed into a compact having internal pores, and then sintered. The sintered compact is immersed and then submerged in a phenolic polymer solution to uniformly fill the pores of the compact with phenolic polymer. The compact is then heated to pyrolyze the phenolic polymer into carbon in the form of a foam. Then the sodium chloride of the compact is leached away with water, and the remaining product is freeze dried to provide the carbon, or catalytically impregnated carbon, foam.

  19. [Cost-effectiveness of a TLC-NOSF polyurethane foam dressing].

    PubMed

    Arroyo Ana, Abejón; Alvarez Vázquez, Juan Carlos; Blasco García, Carmen; Bermejo Martínez, Mariano; López Casanova, Pablo; Cuesta Cuesta, Juan José; De Haro Fernández, Francisco; Mateo Marín, Emilia; Segovia Gómez, Teresa; Villar Rojas, Antonio Erasto

    2012-11-01

    Chronic wounds represent a drain on the Spanish health system, nowdays is necessary an optimization of the resources used and that is for this that is necessary justify the use of the products over others through cost-effective studies for to show the economic benefit to professionals and the life quality of patient. This article compares the use of a new technology for format polyurethane foam, TLC-NOSF, with the most commonly used products for treating wounds. This comparison is made using a cost-effectiveness model (Markov Model). The results demonstrate that treatment with polyurethane foam dressing with TLC-NOSF are cost-effective versus treatments with polyurethane foams most commonly used in Spain.

  20. [The therapeutic effect of nanometer silver impregnated dressing on gunshot wounds after being immersed in brine and tapwater in rabbits].

    PubMed

    Chen, Bi; Ding, Guo-bin; Tang, Chao-wu

    2004-03-22

    To investigate the therapeutic effect of nanometer silver impregnated dressing on gunshot wounds after being immersed in brine and tapwater in rabbits. Rabbits were randomly divided into two groups after receiving gunshot wounds in both lower limbs. In group 1, the wounded limbs on the experimental side were immersed in brine for 5 h; in group 2, the wounded limbs on experimental side were immersed in tapwater for 5 h. All the wounds were treated with nanometer silver impregnated dressing on the experimental sides, while those of the control sides were treated with vaseline dressing. Biopsy was done after 30 min and 1, 2, 3, 4, 5 h, respectively. In group 1, the onset of inflammation around the wounds of the experimental sides was delayed, the inflammatory response was less serious, and the wounds were dry with less exudation compared to the controls. The mean healing time of the entry wounds on experimental and control sides was (29.4 +/- 6.6) d and (36.3 +/- 6.0) d (P < 0.01), respectively, and that of the exit wounds on experimental and control sides was (20.1 +/- 6.0) d and (27.3 +/- 5.7) d (P < 0.01), respectively. In group 2, only one of the experimental wounds showed mild inflammation, while all of the control wounds showed serious inflammation with much exudation. The mean healing time of the entry wounds on experimentsides was (13.0 +/- 1.52) d, while that on control sides was (16.0 +/- 3.10) d (P < 0.01). The mean healing time of exit wounds on experimental sides was (11.0 +/- 2.75) d, and those of the control sides was (15.6 +/- 2.85) d (P < 0.01). The nanometer silver impregnated dressing can control infection and accelerate healing in gunshot wounds in rabbits.

  1. Preparation of amine-impregnated silica foams using agar as the gelling agent

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jardim, Iara M., E-mail: iaramj01@yahoo.com.br

    In this work we successfully prepared amine-impregnated gel-cast silica foams using agar and atmospheric air as the gelling agent and heat treatment atmosphere, respectively. The concentration of 3,6-anhydrogalactose in agar was evaluated by ultraviolet–visible spectroscopy (UV–Vis). The obtained foams were examined by Fourier transform infrared spectroscopy (FTIR), thermogravimetric analysis (TG) coupled to mass spectrometry (TG-MS), scanning electron microscopy (SEM), X-ray microtomography (micro-CT), and Archimedes method. The cold crushing strength of the materials prepared in this work was assessed using a mechanical testing stage available in the micro-CT system. The obtained foams exhibited a highly interconnected pore network, with an expressivemore » presence of open pores. Samples heat-treated at 1300 °C for 2 h showed both an expressive porosity (≈ 77%) and a significant cold crushing strength (≈ 1.4 MPa). It was observed that the calcination of the prepared materials at 1200 °C for times as long as 16 h may lead to the rupture of pore walls. FTIR and TG-MS revealed that amine groups were properly incorporated into the foams structure. - Highlights: •Successful preparation of amine-impregnated gel-cast silica foams •Agar used as the gelling agent •Samples with expressive porosity and cold crushing strength •Sintering times as long as 16 h led to the rupture of the pore network.« less

  2. Dressing for alveolopalatal wounds after alveolar bone grafting.

    PubMed

    Kondoh, Shoji; Matsuo, Kiyoshi; Yuzuriha, Shunsuke; Kikuchi, Nirou; Ban, Ryokuya

    2003-09-01

    Cotton gauze with alpha cyanoacrylate was used for alveolopalatal wound dressing after alveolar bone grafting to treat 93 alveolar clefts in 74 cleft patients to reduce mechanical injuries, tension for wound dehiscence, and adhesion of food remnants. T-shaped cotton gauze was put on the gingivoperiosteal flaps and was impregnated with cyanoacrylate. The procedure required no preoperative preparation and its intraoperative execution took less than 5 minutes. The gauze with cyanoacrylate was removed approximately 1 week after surgery. No infection was observed at any of the operational sites, but tiny fistulas developed at four of them. The mean bone graft score was 1.4 point. No complications such as thermal injury resulted from the use of cyanoacrylate. Gauze impregnated with cyanoacrylate proved to be a convenient and dependable dressing for alveolopalatal wounds resulting from gingivoperiosteoplasty for alveolar bone grafting.

  3. A multilayered polyurethane foam technique for skin graft immobilization.

    PubMed

    Nakamura, Motoki; Ito, Erika; Kato, Hiroshi; Watanabe, Shoichi; Morita, Akimichi

    2012-02-01

    Several techniques are applicable for skin graft immobilization. Although the sponge dressing is a popular technique, pressure failure near the center of the graft is a weakness of the technique that can result in engraftment failure. To evaluate the efficacy of a new skin graft immobilization technique using multilayered polyurethane foam in vivo and in vitro. Twenty-six patients underwent a full-thickness skin graft. Multiple layers of a hydrocellular polyurethane foam dressing were used for skin graft immobilization. In addition, we created an in vitro skin graft model that allowed us to estimate immobilization pressure at the center and edges of skin grafts of various sizes. Overall mean graft survival was 88.9%. In the head and neck region (19 patients), mean graft survival was 93.6%. Based on the in vitro outcomes, this technique supplies effective pressure (<30 mmHg) to the center region of the skin graft. This multilayered polyurethane foam dressing is simple, safe, and effective for skin graft immobilization. © 2011 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  4. The cost-benefit of using soft silicone multilayered foam dressings to prevent sacral and heel pressure ulcers in trauma and critically ill patients: a within-trial analysis of the Border Trial.

    PubMed

    Santamaria, Nick; Liu, Wei; Gerdtz, Marie; Sage, Sarah; McCann, Jane; Freeman, Amy; Vassiliou, Theresa; DeVincentis, Stephanie; Ng, Ai W; Manias, Elizabeth; Knott, Jonathan; Liew, Danny

    2015-06-01

    Little is known about the cost-benefit of soft silicone foam dressings in pressure ulcer (PU) prevention among critically ill patients in the emergency department (ED) and intensive care unit (ICU). A randomised controlled trial to assess the efficacy of soft silicone foam dressings in preventing sacral and heel PUs was undertaken among 440 critically ill patients in an acute care hospital. Participants were randomly allocated either to an intervention group with prophylactic dressings applied to the sacrum and heels in the ED and changed every 3 days in the ICU or to a control group with standard PU prevention care provided during their ED and ICU stay. The results showed a significant reduction of PU incidence rates in the intervention group (P = 0·001). The intervention cost was estimated to be AU$36·61 per person based on an intention-to-treat analysis, but this was offset by lower downstream costs associated with PU treatment (AU$1103·52). Therefore, the average net cost of the intervention was lower than that of the control (AU$70·82 versus AU$144·56). We conclude that the use of soft silicone multilayered foam dressings to prevent sacral and heel PUs among critically ill patients results in cost savings in the acute care hospital. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  5. Loofah sponge as an interface dressing material in negative pressure wound therapy: results of an in vivo study.

    PubMed

    Tuncel, Umut; Turan, Aydin; Markoc, Fatma; Erkorkmaz, Unal; Elmas, Cigdem; Kostakoglu, Naci

    2014-03-01

    Since the introduction of negative pressure wound therapy (NPWT), the physiological effects of various interface dressing materials have been studied. The purpose of this experimental study was to compare the use of loofah sponge to standard polyurethane foam or a cotton gauze sponge. Three wounds, each measuring 3 cm x 3 cm, were created by full-thickness skin excision on the dorsal sides of 24 New Zealand adult white rabbits. The rabbits were randomly divided into four groups of six rabbits each. In group 1 (control), conventional saline-moistened gauze dressing was provided and changed at daily intervals. The remaining groups were provided NPWT dressings at -125 mm Hg continuous pressure. This dressing was changed every 3 days for 9 days; group 2 was provided polyurethane foam, group 3 had conventional saline-soaked antimicrobial gauze, and group 4 had loofah sponge. Wound area measurements and histological findings (inflammation, granulation tissue, neovascularization, and reepithelialization) were analyzed on days 3, 6, and 9. Wound area measurements at these intervals were significantly different between the control group and study groups (P<0.05). Granulation and neovascularization scores were also significantly different between the control and treatment groups at day 3 (P=0.002). No differences in any of the healing variables studied were observed between the other three dressing materials. According to scanning electron microscopy analysis of the three interface materials, the mean pore size diameter of foam and gauze interface materials was 415.80±217.58 μm and 912.33±116.88 μm, respectively. The pore architecture of foam was much more regular than that of gauze. The average pore size diameter of loofah sponge was 736.83±23.01 μm; pores were hierarchically located--ie, the smaller ones were usually peripheral and larger ones werecentral. For this study, the central part of loofah sponge was discarded to achieve a more homogenous structure of interface material. Loofah sponge study results were similar to those using gauze or foam, but the purchase price of loofah sponge is lower than that of currently available interface dressings. More experimental, randomized controlled studies are needed to confirm these results.

  6. Polyurethane Foam Wound Dressing Technique for Areola Skin Graft Stabilization and Nipple Protection After Nipple-Areola Reconstruction.

    PubMed

    Satake, Toshihiko; Muto, Mayu; Nagashima, Yu; Haga, Shoko; Homma, Yuki; Nakasone, Reiko; Kadokura, Marina; Kou, Seiko; Fujimoto, Hiroshi; Maegawa, Jiro

    2018-04-01

    We describe a new wound management technique using a soft dressing material to stabilize the areola skin graft and protect the nipple after nipple-areola reconstruction at the final stage of breast reconstruction. We introduced a center-fenestrated multilayered hydrocellular polyurethane foam dressing material that provides adequate pressure and retains a moist environment for a smooth skin graft "take." Moreover, the reconstructed nipple can be monitored at any time through the fenestrated window for adequate blood circulation. Altogether, this simple and inexpensive wound dressing technique improves the clinical outcome. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  7. Real-time monitoring of moisture levels in wound dressings in vitro: an experimental study.

    PubMed

    McColl, David; Cartlidge, Brian; Connolly, Patricia

    2007-10-01

    Retaining an appropriate level of moisture at the interface between a healing wound and an applied dressing is considered to be critical for effective wound healing. Failure to control exudate at this interface can result in maceration or drying out of the wound surface. The ability to control moisture balance at the wound interface is therefore a key aspect of wound dressing performance. To date it has not been possible to monitor in any effective manner the distribution of moisture within dressings or how this varies with time. A new measurement system is presented based on sensors placed at the wound/dressing interface which are capable of monitoring moisture levels in real time. The system comprises a model wound bed and sensor array complete with fluid injection path to mimic exudate flow. Eight monitoring points, situated beneath the test dressing, allow the moisture profile across the complete dressing to be measured both during and after fluid injection. The system has been used to evaluate the performance of four foam dressings, a composite hydrofibre dressing and a film dressing. Stark contrasts in the performance of the wound contact layer were found between the different wound dressing types. The composite hydrofibre dressing retained moisture at the wound interface throughout the experiments while areas of the foam dressing quickly became dry, even during constant injection of fluid. The abundance of sensors allowed a moisture map of the surface of the wound dressing to be constructed, illustrating that the moisture profile was not uniform across several of the dressings tested during absorption and evaporation of liquid. These results raise questions as to how the dressings behave on a wound in vivo and indicate the need for a similar clinical monitoring system for tracking wound moisture levels.

  8. Micro- and macromechanical effects on the wound bed of negative pressure wound therapy using gauze and foam.

    PubMed

    Borgquist, Ola; Gustafsson, Lotta; Ingemansson, Richard; Malmsjö, Malin

    2010-06-01

    Negative pressure wound therapy (NPWT) results in 2 types of tissue deformation, macrodeformation (ie, wound contraction) and microdeformation (ie, the interaction of tissue and dressing on a microscopic level). These effects have been delineated for one type of wound filler, foam, but not for gauze. The mechanical deformation initiates a signaling cascade which ultimately leads to wound healing. The aim of the present study was to examine the effect of gauze and foam on macro- and microdeformation during treatment with negative pressure. An in vivo porcine peripheral wound model was used. NPWT was applied for 72 hours at 0, -75, and -125 mm Hg, using either foam or gauze as wound filler. The mechanical effects of NPWT were examined by measuring the wound surface area reduction and by histologic analysis of the wound bed tissue. Similar degrees of wound contraction (macrodeformation) were seen during NPWT regardless if foam or gauze was used. After negative pressure had been discontinued, the wound stayed contracted. There was no difference in wound contraction between -75 and -125 mm Hg. Biopsies of the wound bed revealed a repeating pattern of wound surface undulations and small tissue blebs ("tissue mushrooms") were pulled into the pores of the foam dressing and the spaces between the threads in the gauze dressing (microdeformation). This pattern was obvious in wounds treated both with foam and gauze, at atmospheric pressure (0 mm Hg) as well as at subatmospheric pressures (-75 and -125 mm Hg). The degrees of micro- and macrodeformation of the wound bed are similar after NPWT regardless if foam or gauze is used as wound filler.

  9. Experimental investigation of solidification in metal foam enhanced phase change material

    NASA Astrophysics Data System (ADS)

    Beyne, W.; Bağci, O.; Huisseune, H.; Canière, H.; Danneels, J.; Daenens, D.; De Paepe, M.

    2017-10-01

    A major challenge for the use of phase change materials (PCMs) in thermal energy storage (TES) is overcoming the low thermal conductivity of PCM’s. The low conductivity gives rise to limited power during charging and discharging TES. Impregnating metal foam with PCM, however, has been found to enhance the heat transfer. On the other hand, the effect of foam parameters such as porosity, pore size and material type has remained unclear. In this paper, the effect of these foam parameters on the solidification time is investigated. Different samples of PCM-impregnated metal foam were experimentally tested and compared to one without metal foam. The samples varied with respect to choice of material, porosity and pore size. They were placed in a rectangular cavity and cooled from one side using a coolant flowing through a cold plate. The other sides of the rectangular cavity were Polymethyl Methacrylate (PM) walls exposed to ambient. The temperature on the exterior walls of the cavity was monitored as well as the coolant flow rate and its temperature. The metal foam inserts reduced the solidification times by at least 25 %. However, the difference between the best performing and worst performing metal foam is about 28 %. This shows a large potential for future research.

  10. Hemostatic kaolin-polyurethane foam composites for multifunctional wound dressing applications.

    PubMed

    Lundin, Jeffrey G; McGann, Christopher L; Daniels, Grant C; Streifel, Benjamin C; Wynne, James H

    2017-10-01

    There are numerous challenges associated with the acute care of traumatic limb injuries in forward military settings. A lack of immediate medical facilities necessitates that the wound dressing perform multiple tasks including exudate control, infection prevention, and physical protection of the wound for extended periods of time. Here, kaolin was incorporated into recently developed robust polyurethane (PU) hydrogel foams at 1-10wt% in an effort to impart hemostatic character. ATR-IR and gel fraction analysis demonstrated that the facile, one-pot synthesis of the PU hydrogel was unaffected by kaolin loading, as well as the use of a non-toxic catalyst, which significantly improved cytocompatibility of the materials. Kaolin was generally well dispersed throughout the PU matrix, though higher loadings exhibited minor evidence of aggregation. Kaolin-PU composites exhibited burst release of ciprofloxacin over 2h, the initial release rates of which increased with kaolin loading. Kaolin loading imparted excellent hemostatic character to the PU foams at relatively low loading levels (5wt%). This work demonstrates the simple and inexpensive synthesis of robust, hemostatic, and absorptive kaolin-PU foams that have promising potential as multifunctional wound dressing materials. Published by Elsevier B.V.

  11. Negative pressure wound therapy combined with acoustic pressure wound therapy for infected post surgery wounds: a case series.

    PubMed

    Howell-Taylor, Melania; Hall, Macy G; Brownlee Iii, William J; Taylor, Mary

    2008-09-01

    Acute infection of surgical incision sites often requires specialized wound care in preparation for surgical closure. Optimal therapy for preparing such wounds for a secondary closure procedure remains uncertain. The authors report wound outcomes after administering acoustic pressure wound therapy in conjunction with negative pressure wound therapy with reticulated open-cell foam dressing changes to assist with bacteria removal from open, infected surgical-incision sites in preparation for secondary surgical closure in three patients. Before incorporating acoustic pressure wound therapy at the authors' facility, the average negative pressure wound therapy with reticulated open-cell foam dressing course prior to secondary surgical closure was 30 days; with its addition, two of three patients underwent successful surgical closure with no postoperative complications after 21 and 14 days, respectively; one patient succumbed to nonwound-related complications before wound closure. Larger, prospective studies are needed to evaluate combining negative pressure wound therapy with reticulated open-cell foam dressing and acoustic pressure wound therapy for infected, acute post surgery wounds.

  12. Antibacterial potency of V.A.C. GranuFoam Silver(®) Dressing.

    PubMed

    Sachsenmaier, Saskia; Peschel, Andreas; Ipach, Ingmar; Kluba, Torsten

    2013-10-01

    V.A.C.(®) GranuFoam™ therapy is regularly used in the surgical therapy of infected wounds and soft tissue injuries. Silver nanoparticles can destroy bacterial cell walls and inhibit enzymes for cell replication. Silver dressings are therefore successfully used for many indications in wound therapy. In this study, we investigated the antimicrobial potency of ionic silver released from the silver-coated V.A.C.(®) GranuFoam™ during vacuum therapy. Silver dressing was exposed to agar plates populated with bacteria to measure silver release. A total of 15 agar plates colonised with either Staphylococcus aureus populations or with Staphylococcus epidermidis, were loaded with V.A.C. GranuFoam Silver(®) Dressing polyurethane foam (KCI, San Antonio, Texas). Each of 13 pieces of silver-coated foam was applied to an agar plate. Two plates were loaded with conventional black foam without any coating. After connecting to a vacuum pump, the vacuum therapy of the 15 plates lasted 5 days. The zone of inhibition of bacterial growth around the foam was measured daily. Silver release was also determined as a function of time. At each time point, there was evidence of silver in the agar independent of bacterial colonisation. The S. aureus agar showed a consecutive increase in silver concentration from baseline upon 48 h after exposure to the negative pressure of V.A.C. therapy. An increasing mean silver level after 48, 72 and 96 h was measured under V.A.C. therapy with a peak value after 120 h. In contrast, the results from the S. epidermidis plates did not follow a linear pattern. At the beginning of vacuum therapy, we documented a rise in silver concentration. After 48-96h, the silver levels fluctuated. A maximum zone of inhibition in both bacterial colonised plates (S. aureus and S. epidermidis) was found 39 h after the start of the V.A.C. GranuFoam Silver(®) therapy. From our results, we confirmed the antimicrobial effect of the silver ions against S. aureus and S. epidermidis under continuous V.A.C. GranuFoam(®) Silver therapy with a negative pressure of 25 mmHg. Furthermore we could quantify the amounts of silver, which were released from the foam under negative pressure as a function of time. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. A preliminary study of silver sodium zirconium phosphate polyurethane foam wound dressing on wounds of the distal aspect of the forelimb in horses.

    PubMed

    Kelleher, Maureen E; Kilcoyne, Isabelle; Dechant, Julie E; Hummer, Emma; Kass, Philip H; Snyder, Jack R

    2015-04-01

    To determine if application of silver sodium zirconium phosphate polyurethane semi-occlusive foam (SPF) dressing would improve measures of wound healing and decrease bacterial contamination compared with a non-adherent, absorbent dressing applied to wounds created on the distal aspect of the equine limb. Controlled randomized experimental study. Adult Quarter Horse and Thoroughbred horses (n = 5). One 6.25 cm(2) wound was created on the dorsomedial aspect of the proximal metacarpus on each forelimb. A SPF dressing was applied to 1 randomly assigned limb as a treatment and a non-adherent, absorbent dressing was applied to the opposite limb as control. Bandages were changed every 3 days for 60 days. Granulation tissue was scored every 3 days, wound area measured every 6 days, and wound bed was cultured every 12 days. SPF-treatment wounds had significantly decreased wound area and decreased granulation tissue scores when evaluated <30 days and over the 60 day study, although complete wound healing times were not significantly different. Bacteria were cultured from all wounds at varying times throughout the study. The SPF wound dressing improved some measures of wound healing compared with the control dressing, most significantly during the first 30 days. This suggests that the SPF wound dressing may be useful in the early management of wounds on the equine lower limb. Further studies using the SPF dressing are needed to characterize the temporal and cellular effects on wound healing and evaluate this dressing in a clinical environment. © Copyright 2014 by The American College of Veterinary Surgeons.

  14. Analysis of Effective Interconnectivity of DegraPol-foams Designed for Negative Pressure Wound Therapy

    PubMed Central

    Milleret, Vincent; Bittermann, Anne Greet; Mayer, Dieter; Hall, Heike

    2009-01-01

    Many wounds heal slowly and are difficult to manage. Therefore Negative Pressure Wound Therapy (NPWT) was developed where polymer foams are applied and a defined negative pressure removes wound fluid, reduces bacterial burden and increases the formation of granulation tissue. Although NPWT is used successfully, its mechanisms are not well understood. In particular, different NPWT dressings were never compared. Here a poly-ester urethane Degrapol® (DP)-foam was produced and compared with commercially available dressings (polyurethane-based and polyvinyl-alcohol-based) in terms of apparent pore sizes, swelling and effective interconnectivity of foam pores. DP-foams contain relatively small interconnected pores; PU-foams showed large pore size and interconnectivity; whereas PVA-foams displayed heterogeneous and poorly interconnected pores. PVA-foams swelled by 40 %, whereas DP- and PU-foams remained almost without swelling. Effective interconnectivity was investigated by submitting fluorescent beads of 3, 20 and 45 μm diameter through the foams. DP- and PU-foams removed 70-90 % of all beads within 4 h, independent of the bead diameter or bead pre-adsorption with serum albumin. For PVA-foams albumin pre-adsorbed beads circulated longer, where 20 % of 3 μm and 10 % of 20 μm diameter beads circulated after 96 h. The studies indicate that efficient bead perfusion does not only depend on pore size and swelling capacity, but effective interconnectivity might also depend on chemical composition of the foam itself. In addition due to the efficient sieve-effect of the foams uptake of wound components in vivo might occur only for short time suggesting other mechanisms being decisive for success of NPWT.

  15. Polymer-Derived Silicoboron Carbonitride Foams for CO2 Capture: From Design to Application as Scaffolds for the in Situ Growth of Metal-Organic Frameworks.

    PubMed

    Sandra, Fabien; Depardieu, Martin; Mouline, Zineb; Vignoles, Gérard L; Iwamoto, Yuji; Miele, Philippe; Backov, Rénal; Bernard, Samuel

    2016-06-06

    A template-assisted polymer-derived ceramic route is investigated for preparing a series of silicoboron carbonitride (Si/B/C/N) foams with a hierarchical pore size distribution and tailorable interconnected porosity. A boron-modified polycarbosilazane was selected to impregnate monolithic silica and carbonaceous templates and form after pyrolysis and template removal Si/B/C/N foams. By changing the hard template nature and controlling the quantity of polymer to be impregnated, controlled micropore/macropore distributions with mesoscopic cell windows are generated. Specific surface areas from 29 to 239 m(2)  g(-1) and porosities from 51 to 77 % are achieved. These foams combine a low density with a thermal insulation and a relatively good thermostructural stability. Their particular structure allowed the in situ growth of metal-organic frameworks (MOFs) directly within the open-cell structure. MOFs offered a microporosity feature to the resulting Si/B/C/N@MOF composite foams that allowed increasing the specific surface area to provide CO2 uptake of 2.2 %. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. A multi-center, randomized, clinical trial comparing adhesive polyurethane foam dressing and adhesive hydrocolloid dressing in patients with grade II pressure ulcers in primary care and nursing homes.

    PubMed

    Guillén-Solà, Mireia; Soler Mieras, Aina; Tomàs-Vidal, Antònia M

    2013-12-21

    Pressure ulcers (PrUs) are ischemic wounds in the skin and underlying tissues caused by long-standing pressure force over an external bone or cartilaginous surface. PrUs are an important challenge for the overall health system because can prolong patient hospitalization and reduce quality of life. Moreover, 95% of PrUs are avoidable, suggesting they are caused by poor quality care assistance. PrUs are also costly, increasing national costs. For example, they represent about 5% of overall annual health expenses in Spain. Stages I and II PrUs have a combined prevalence of 65%. According main clinical guidelines, stage II PrUs (PrU-IIs) are usually treated by applying special dressings (polyurethane or hydrocolloid). However, little scientific evidence regarding their efficacy has been identified in scientific literature. Our aim is to assess the comparative efficacy of adhesive polyurethane foam and hydrocolloid dressings in the treatment of PrU-IIs in terms of healed ulcer after 8 weeks of follow-up. This paper describes the development and evaluation protocol of a randomized clinical trial of two parallel treatment arms. A total of 820 patients with at least 1 PrU-II will be recruited from primary health care and home care centers. All patients will receive standardized healing procedures and preventive measures (e.g. positional changes and pressure-relieving support surfaces), following standardized procedures. The main outcome will be the percentage of wounds healed after 8 weeks. Secondary outcomes will include cost-effectiveness, as evaluated by cost per healed ulcer and cost per treated patient and safety evaluated by adverse events. This trial will address the hypothesis that hydrocolloid dressings will heal at least 10% more stage II PrUs and be more cost-effective than polyurethane foam dressings after 8 weeks. This trial has been registered with controlled-trials number ISCRCTN57842461 and EudraCT 2012-003945-14.

  17. High Strength Wood-based Sandwich Panels reinforced with fiberglass and foam

    Treesearch

    Jinghao Li; John F. Hunt; Shaoqin Gong; Zhiyong Cai

    2014-01-01

    Mechanical analysis is presented for new high-strengthsandwich panels made from wood-based phenolic impregnated laminated paper assembled with an interlocking tri-axial ribbed core. Four different panel configurations were tested, including panels with fiberglass fabric bonded to both outside faces with self-expanding urethane foam used to fill the ribbed core. The...

  18. Antimicrobial activity of silver nanoparticles impregnated wound dressing

    NASA Astrophysics Data System (ADS)

    Shinde, V. V.; Jadhav, P. R.; Patil, P. S.

    2013-06-01

    In this work, silver nanoparticles were synthesized by simple wet chemical reduction method. The silver nitrate was reduced by Sodium borohydride used as reducing agent and Poly (vinyl pyrrolidone) (PVP) as stabilizing agent. The formation of silver nanoparticles was evaluated by UV-visible spectroscope and transmission electron microscope (TEM). Absorption spectrum consist two plasmon peaks at 410 and 668 nm revels the formation of anisotropic nanoparticles confirmed by TEM. The formation of silver nanoparticles was also evidenced by dynamic light scattering (DLS) study. DLS showed polydisperse silver nanoparticles with hydrodynamic size 32 nm. Protecting mechanism of PVP was manifested by FT-Raman study. Silver nanoparticles were impregnated into wound dressing by sonochemical method. The Kirby-Bauer disc diffusion methods were used for antimicrobial susceptibility testing. The antimicrobial activity of the samples has been tested against gram-negative bacterium Escherichia coli and gram-positive bacterium Staphylococcus aureus.

  19. Spacecraft surgical scrub system

    NASA Technical Reports Server (NTRS)

    Abbate, M.

    1980-01-01

    Ease of handling and control in zero gravity and minimizing the quantity of water required were prime considerations. The program tasks include the selection of biocidal agent from among the variety used for surgical scrub, formulation of a dispensing system, test, and delivery of flight dispensers. The choice of an iodophore was based on effectiveness on single applications, general familiarity among surgeons, and previous qualification for space use. The delivery system was a choice between the squeeze foamer system and impregnated polyurethane foam pads. The impregnated foam pad was recommended because it is a simpler system since the squeeze foamer requires some applicator to effectively clean the skin surfaces, whereas the form pad is the applicator and agent combined. Testing demonstrated that both systems are effective for use as surgical scrubs.

  20. Fabrication of a form- and size-variable microcellular-polymer-stabilized metal nanocomposite using supercritical foaming and impregnation for catalytic hydrogenation

    PubMed Central

    2012-01-01

    This article presents the fabrication of size-controllable and shape-flexible microcellular high-density polyethylene-stabilized palladium nanoparticles (Pd/m-HDPE) using supercritical foaming, followed by supercritical impregnation. These nanomaterials are investigated for use as heterogeneous hydrogenation catalysts of biphenyls in supercritical carbon dioxide with no significant surface and inner mass transfer resistance. The morphology of the Pd/m-HDPE is examined using scanning electron microscopy images of the pores inside Pd/m-HDPE catalysts and transmission electron microscopy images of the Pd particles confined in an HDPE structure. This nanocomposite simplifies industrial design and operation. These Pd/m-HDPE catalysts can be recycled easily and reused without complex recovery and cleaning procedures. PMID:22651135

  1. ["Getting to zero infections" in hemodialysis].

    PubMed

    Leonardi, Gianluca; Finotto, Giuseppe; Talaia, Marinella; Nappo, Angelo; Dolla, Caterina; Di Vico, Maria Cristina; Diena, Davide; Linsalata, Antonio; Guarena, Cesare; Barbaro, Silvana; Biancone, Luigi

    2015-01-01

    We describe two measures adopted in hemodialysis outpatient population in order to reduce Central Venous Catheter (CVC) related infections. The first is a nurse staff training in the field project and the second deals with the employment of chlorhexidine-impregnated dressing devices. These actions were performed after high infection rates were observed through a dedicated register. In the limited assistance dialysis center, direct observation (12/2012-02/2013) quantified the gap between the observed and expected health care behaviour. Training needs were defined and a 40 hours nurse staff training in the field was performed on two occasions. In the hospital dialysis center, we introduced alcoholic 2% chlorhexidine solution and chlorhexidine-impregnated dressing devices to the exit site (CHG-Tegaderm and BioPatch). Infections (cumulatively bacteremia/sepsis/skin exit/subcutaneous tunnel) were monitored continuously. Infection rates at the two locations were progressively reduced, reaching a value of zero at the limited assistance center. Nurse staff training in the field produced: two patient reports and three CVC management protocols, Italian language translation of the "The 5 moments of dialysis" WHO poster, alcoholic 2% chlorhexidine adoption to exit-site medication and improvement of environment cleaning/sanitation actions. Our experience shows that continuously monitoring infection rates represents the first step for timely corrective action. The continuous updating of health personnel, codified prevention measures and an ongoing commitment to raise awareness in a routine practice, allows us to obtain the goal of "getting to zero infections". The staff training produced equal or superior results compared to the isolated use of new chlorhexidine-impregnated dressing devices.

  2. Silver-pig skin nanocomposites and mesenchymal stem cells: suitable antibiofilm cellular dressings for wound healing.

    PubMed

    Pérez-Díaz, Mario Alberto; Silva-Bermudez, Phaedra; Jiménez-López, Binisa; Martínez-López, Valentín; Melgarejo-Ramírez, Yaaziel; Brena-Molina, Ana; Ibarra, Clemente; Baeza, Isabel; Martínez-Pardo, M Esther; Reyes-Frías, M Lourdes; Márquez-Gutiérrez, Erik; Velasquillo, Cristina; Martínez-Castañon, Gabriel; Martinez-Gutierrez, Fidel; Sánchez-Sánchez, Roberto

    2018-01-10

    Treatment of severe or chronic skin wounds is an important challenge facing medicine and a significant health care burden. Proper wound healing is often affected by bacterial infection; where biofilm formation is one of the main risks and particularly problematic because it confers protection to microorganisms against antibiotics. One avenue to prevent bacterial colonization of wounds is the use of silver nanoparticles (AgNPs); which have proved to be effective against non-multidrug-resistant and multidrug-resistant bacteria. In addition, the use of mesenchymal stem cells (MSC) is an excellent option to improve wound healing due to their capability for differentiation and release of relevant growth factors. Finally, radiosterilized pig skin (RPS) is a biomatrix successfully used as wound dressing to avoid massive water loss, which represents an excellent carrier to deliver MSC into wound beds. Together, AgNPs, RPS and MSC represent a potential dressing to control massive water loss, prevent bacterial infection and enhance skin regeneration; three essential processes for appropriate wound healing with minimum scaring. We synthesized stable 10 nm-diameter spherical AgNPs that showed 21- and 16-fold increase in bacteria growth inhibition (in comparison to antibiotics) against clinical strains Staphylococcus aureus and Stenotrophomonas maltophilia, respectively. RPS samples were impregnated with different AgNPs suspensions to develop RPS-AgNPs nanocomposites with different AgNPs concentrations. Nanocomposites showed inhibition zones, in Kirby-Bauer assay, against both clinical bacteria tested. Nanocomposites also displayed antibiofilm properties against S. aureus and S. maltophilia from RPS samples impregnated with 250 and 1000 ppm AgNPs suspensions, respectively. MSC were isolated from adipose tissue and seeded on nanocomposites; cells survived on nanocomposites impregnated with up to 250 ppm AgNPs suspensions, showing 35% reduction in cell viability, in comparison to cells on RPS. Cells on nanocomposites proliferated with culture days, although the number of MSC on nanocomposites at 24 h of culture was lower than that on RPS. AgNPs with better bactericide activity than antibiotics were synthesized. RPS-AgNPs nanocomposites impregnated with 125 and 250 ppm AgNPs suspensions decreased bacterial growth, decreased biofilm formation and were permissive for survival and proliferation of MSC; constituting promising multi-functional dressings for successful treatment of skin wounds.

  3. Modified of an Accepted Animal Model of Osteomyelitis to Simulate and Evaluate Treatment of War Extremity Wounds. Addendum

    DTIC Science & Technology

    2012-07-01

    transferred to the burn wound from contaminated surfaces, equipment, or the hands of health care workers.23–26 Of the many bacterial microorganisms that...Dressings A variety of dressings impregnated with elemental silver have been approved by the US Food and Drug Admin- istration (FDA) as topical therapy for...23. Sherertz RJ, Sullivan ML. An outbreak of infections with Acinetobacter calcoaceticus in burn patients: contamination of patients’ mattresses. J

  4. Rapid hemostatic and mild polyurethane-urea foam wound dressing for promoting wound healing.

    PubMed

    Liu, Xiangyu; Niu, Yuqing; Chen, Kevin C; Chen, Shiguo

    2017-02-01

    A novel rapid hemostatic and mild polyurethane-urea foam (PUUF) wound dressing was prepared by the particle leaching method and vacuum freeze-drying method using 4, 4-Methylenebis(cyclohexyl isocyanate), 4,4-diaminodicyclohexylmethane and poly (ethylene glycol) as raw materials. And X-ray diffraction (XRD), tensile test, differential scanning calorimetry (DSC) and thermogravimetry (TG) were used to its crystallinity, stress and strain behavior, and thermal properties, respectively. Platelet adhesion, fibrinogen adhesion and blood clotting were performed to evaluate its hemostatic effect. And H&E staining and Masson Trichrome staining were used to its wound healing efficacy. The results revealed the pore size of PUUF is 50-130μm, and its porosity is 71.01%. Porous PUUF exhibited good water uptake that was benefit to adsorb abundant wound exudates to build a regional moist environment beneficial for wound healing. The PUUF wound dressing exhibit better blood coagulation effect than commercial polyurethane dressing (CaduMedi). Though both PUUF and CaduMedi facilitated wound healing generating full re-epithelialization within 13days, PUUF was milder and lead to more slight inflammatory response than CaduMedi. In addition, PUUF wound dressing exhibited lower cytotoxicity than CaduMedi against NIH3T3 cells. Overall, porous PUUF represents a novel mild wound dressing with excellent water uptake, hemostatic effect and low toxicity, and it can promote wound healing and enhance re-epithelialization. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. 150 patient experiences with a soft silicone foam dressing.

    PubMed

    Bateman, Sharon Dawn

    Pain, malodour and exudate from acute and chronic wounds can be catastrophic to the patient. Excessive exudate results in significant tissue damage to the wound bed and surrounding skin, reduces quality of life, and often requires costly specialist service input. Effective wound assessment and management including appropriate dressing choice is, therefore, paramount to ensure wound healing can take place in a timely manner. This observational evaluation explores 150 ward-based patients who presented with acute and chronic exuding wounds; it examines and evaluates the proposed benefits of the Cutimed(®) Siltec foam dressing range over a 4-month period in an acute hospital setting. The outcomes of the evaluation were exudate management, maceration reduction, atraumatic application and removal, non-adherence and patient experience. The evaluation highlights not only an overall positive improvement in exudate management and maceration reduction, non-adherence, atraumatic application and removal but also emphasises the importance of a positive patient experience in the wound-care journey.

  6. Multiwall carbon nanotube embedded phenolic resin-based carbon foam for the removal of As (V) from contaminated water

    NASA Astrophysics Data System (ADS)

    Rani Agrawal, Pinki; Singh, Nahar; Kumari, Saroj; Dhakate, Sanjay R.

    2018-03-01

    It is well proposed that micron or nano size filters requires to separate adsorbent from water after removal of adsorbate. However, even after filtration trace quantity of adsorbent remains in purified water, which deteriorates the quality of water for potability. To overcome these problems, multi walled carbon nanotube (MWCNT) loaded Carbon Foam (CF) was fabricated by a sacrificial template process. In this process, multi walled carbon nanotubes (MWCNTs) and phenolic resin mixture was used for the impregnation of the polyurethane (PU) template. Impregnated PU Foam stabilized and carbonized to get MWCNTs embedded Carbon Foam (CF). The MWCNT loaded CF (MWCNTs-CF) was used for the removal of As (V) species from water. The proposed foam efficiently removes arsenic (As (V)) from water and it can be easily separated from water after purification without any sophisticated tools. The adsorption capacity of the proposed material was found to be 90.5 μg*g-1 at optimized condition of pH, time and concentration, which is excellent in comparison to several other materials utilized for removal of As (V). Kinetic and isotherm studies reveal that the multilayer adsorption over heterogeneous surface follows pseudo second order kinetics. The adsorption phenomena were further confirmed by several characterization techniques like scanning electron microscope (SEM), x-ray diffraction (XRD) spectroscopy and x-ray photoelectron spectroscopy (XPS).

  7. Preventing Facial Pressure Ulcers in Acute Respiratory Distress Syndrome (ARDS).

    PubMed

    Kim, Ruth S; Mullins, Kimberly

    2016-01-01

    In patients with acute lung injury and/or severe acute respiratory distress syndrome (ARDS), prone positioning is a therapeutic intervention to improve oxygenation. Positioning a patient in a prone position increases the risk of medical device-related pressure ulcers in the facial area. This article summarizes experience with 4 patients with ARDS. Two did not receive pressure ulcer preventive measures and subsequently developed multiple necrotic facial pressure ulcers related to prone positioning for treatment of ARDS. The other 2 patients were managed on a thin silicone foam dressing; neither of these patients developed facial pressure ulcers during pronation therapy. The use of thin soft silicone foam dressings may prevent the development of facial deep tissue injuries in patients receiving prolonged pronation therapy.

  8. In Vitro Parallel Evaluation of Antibacterial Activity and Cytotoxicity of Commercially Available Silver-Containing Wound Dressings.

    PubMed

    Yunoki, Shunji; Kohta, Masushi; Ohyabu, Yoshimi; Iwasaki, Tetsuji

    2015-01-01

    This study evaluated the in vitro antibacterial activity and cytotoxicity of various commercially available silver-containing dressings (Ag dressing). Biohesive Ag (hydrocolloid, silver sulfadiazine), Aquacel® Ag (nonwoven fabric, ionic silver [Ag]), Algisite™ Ag (nonwoven fabric, Ag), Mepilex® Ag (foam, silver sulfate), and PolyMem® Ag (foam, nanocrystalline silver) were tested for characteristics of Ag release, antibacterial activity, and cytotoxicity. The release of Ag was investigated in cell culture medium at immersion periods of 6, 24, and 48 hours. The antibacterial activity against Staphylococcus aureus and Pseudomonas aeruginosa were accessed by a disc diffusion test. The cytotoxicity was evaluated using V79 cells, by an extraction method. The cytotoxicity was not a monotonic function of the antibacterial activity among the Ag dressings and could not be simply explained by Ag-release properties. Biohesive Ag was regarded as a slow-release Ag dressing, showing the lowest cytotoxicity, while the antibacterial activity was classified as "strong" or "significant" against the two species of bacteria. Aquacel Ag and Algisite Ag showed higher antibacterial activity and cytotoxic effects, which were supported by the higher Ag release. Mepilex Ag showed the highest release of Ag, and the cytotoxicity was the highest among the Ag dressings. However, the antibacterial activity was classified as "significant" or "no activity" for P. aeruginosa and S. aureus, respectively. PolyMem Ag showed the lowest Ag release, and the antibacterial activity classified as "significant" or "no activity" for S. aureus and P. aeruginosa, respectively, whereas the cytotoxicity was similar to those of Aquacel Ag and Algisite Ag. The efficacy and adverse effects of the Ag dressings revealed differences that should be considered by clinicians during wound management.

  9. A multi-center, randomized, clinical trial comparing adhesive polyurethane foam dressing and adhesive hydrocolloid dressing in patients with grade II pressure ulcers in primary care and nursing homes

    PubMed Central

    2013-01-01

    Background Pressure ulcers (PrUs) are ischemic wounds in the skin and underlying tissues caused by long-standing pressure force over an external bone or cartilaginous surface. PrUs are an important challenge for the overall health system because can prolong patient hospitalization and reduce quality of life. Moreover, 95% of PrUs are avoidable, suggesting they are caused by poor quality care assistance. PrUs are also costly, increasing national costs. For example, they represent about 5% of overall annual health expenses in Spain. Stages I and II PrUs have a combined prevalence of 65%. According main clinical guidelines, stage II PrUs (PrU-IIs) are usually treated by applying special dressings (polyurethane or hydrocolloid). However, little scientific evidence regarding their efficacy has been identified in scientific literature. Our aim is to assess the comparative efficacy of adhesive polyurethane foam and hydrocolloid dressings in the treatment of PrU-IIs in terms of healed ulcer after 8 weeks of follow-up. Methods/design This paper describes the development and evaluation protocol of a randomized clinical trial of two parallel treatment arms. A total of 820 patients with at least 1 PrU-II will be recruited from primary health care and home care centers. All patients will receive standardized healing procedures and preventive measures (e.g. positional changes and pressure-relieving support surfaces), following standardized procedures. The main outcome will be the percentage of wounds healed after 8 weeks. Secondary outcomes will include cost-effectiveness, as evaluated by cost per healed ulcer and cost per treated patient and safety evaluated by adverse events. Discussion This trial will address the hypothesis that hydrocolloid dressings will heal at least 10% more stage II PrUs and be more cost-effective than polyurethane foam dressings after 8 weeks. Trial registration This trial has been registered with controlled-trials number ISCRCTN57842461 and EudraCT 2012-003945-14. PMID:24359122

  10. A potential bioactive wound dressing based on carboxymethyl cellulose/ZnO impregnated MCM-41 nanocomposite hydrogel.

    PubMed

    Rakhshaei, Rasul; Namazi, Hassan

    2017-04-01

    Lack of antibacterial activity, deficient water vapor and oxygen permeability, and insufficient mechanical properties are disadvantages of existing wound dressings. Hydrogels could absorb wound exudates due to their strong swelling ratio and give a cooling sensation and a wet environment. To overcome these shortcomings, flexible nanocomposite hydrogel films was prepared through combination of zinc oxide impregnated mesoporous silica (ZnO-MCM-41) as a nano drug carrier with carboxymethyl cellulose (CMC) hydrogel. Citric acid was used as cross linker to avoid the cytotoxicity of conventional cross linkers. The prepared nanocomposite hydrogel was characterized using X-ray diffractometry (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), Zeta potential and UV-vis spectroscopy. Results of swelling and erosion tests showed CMC/ZnO nanocomposite hydrogel disintegrated during the first hours of the test. Using MCM-41 as a substrate for ZnO nanoparticles solved this problem and the CMC/ZnO-MCM-41 showed a great improvement in tensile strength (12%), swelling (100%), erosion (53%) and gas permeability (500%) properties. Drug delivery and antibacterial properties of the nanocomposite hydrogel films studied using tetracycline (TC) as a broad spectrum antibiotic and showed a sustained TC release. This could efficiently decrease bandage exchange. Cytocompatibility of the nanocomposite hydrogel films has been analyzed in adipose tissue-derived stem cells (ADSCs) and results showed cytocompatibility of CMC/ZnO-MCM-41. Based on these results the prepared CMC nanocomposite hydrogel containing ZnO impregnated MCM-41, could serve as a kind of promising wound dressing with sustained drug delivery properties. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. A study to evaluate primary dressings for the application of cultured keratinocytes.

    PubMed

    Price, R D; Das-Gupta, V; Frame, J D; Navsaria, H A

    2001-12-01

    Despite the recent improvements in cell culture and dermal regeneration methods, tissue engineering of skin has yet to receive widespread acceptance in the management of burn injuries. The reasons for this are complex and include not only the inherent costs of (particularly) setting up and running such a system but also the continuing difficulties in achieving successful engraftment of the neoepidermis. The latter has previously been addressed in a number of ways, including improving the recipient bed and using pre-confluent delivery systems to allow earlier application of cells to that wound bed. One area that has received little attention is that of the optimal wound dressing to use with this technology; the cells are very poorly attached at early time points, and, in this context, the traditional dressing of paraffin gauze has never been formally assessed in comparison with newer materials. Using a porcine acute wound chamber model, we performed a prospective randomised trial to assess four different wound dressings with reference to the amount of epidermal cover gained and the histological quality of the regenerated skin after 3 weeks. Out of the four materials tested, polyurethane foam (Allevyn) was superior histologically (although equal in take rate with paraffin gauze), whilst polythene sheet (Opsite) and silicone sheet were substantially inferior. We conclude that the traditional dressing used with this technology should be compared with polyurethane foam in a clinical trial. In the future, novel dressings should be formally tested against traditional methods before being adopted. Copyright 2001 The British Association of Plastic Surgeons.

  12. Pitch-based carbon foam and composites and use thereof

    DOEpatents

    Klett, James W.; Burchell, Timothy D.; Choudhury, Ashok

    2006-07-04

    A thermally conductive carbon foam is provided, normally having a thermal conductivity of at least 40 W/mK. The carbon foam usually has a specific thermal conductivity, defined as the thermal conductivity divided by the density, of at least about 75 Wcm.sup.3/m.degree. Kgm. The foam also has a high specific surface area, typically at least about 6,000 m.sup.2/m.sup.3. The foam is characterized by an x-ray diffraction pattern having "doublet" 100 and 101 peaks characterized by a relative peak split factor no greater than about 0.470. The foam is graphitic and exhibits substantially isotropic thermal conductivity. The foam comprises substantially ellipsoidal pores and the mean pore diameter of such pores is preferably no greater than about 340 microns. Other materials, such as phase change materials, can be impregnated in the pores in order to impart beneficial thermal properties to the foam. Heat exchange devices and evaporatively cooled heat sinks utilizing the foams are also disclosed.

  13. Pitch-based carbon foam and composites and uses thereof

    DOEpatents

    Klett, James W.; Burchell, Timothy D.; Choudhury, Ashok

    2004-01-06

    A thermally conductive carbon foam is provided, normally having a thermal conductivity of at least 40 W/m.multidot.K. The carbon foam usually has a specific thermal conductivity, defined as the thermal conductivity divided by the density, of at least about 75 W.multidot.cm.sup.3 /m.multidot..degree.K.multidot.gm. The foam also has a high specific surface area, typically at least about 6,000 m.sup.2 /m.sup.3. The foam is characterized by an x-ray diffraction pattern having "doublet" 100 and 101 peaks characterized by a relative peak split factor no greater than about 0.470. The foam is graphitic and exhibits substantially isotropic thermal conductivity. The foam comprises substantially ellipsoidal pores and the mean pore diameter of such pores is preferably no greater than about 340 microns. Other materials, such as phase change materials, can be impregnated in the pores in order to impart beneficial thermal properties to the foam. Heat exchange devices and evaporatively cooled heat sinks utilizing the foams are also disclosed.

  14. Prospective and randomised evaluation of the protease-modulating effect of oxidised regenerated cellulose/collagen matrix treatment in pressure sore ulcers.

    PubMed

    Kloeters, Oliver; Unglaub, Frank; de Laat, Erik; van Abeelen, Marjolijn; Ulrich, Dietmar

    2016-12-01

    In chronic wounds, excess levels and activity of proteases such as elastase and plasmin have been detected. Oxidised regenerated cellulose/collagen matrix (ORC/collagen matrix) has been reported to ameliorate the wound microenvironment by binding and inactivating excess proteases in wound exudates. In this study, the levels and activity of elastase and plasmin in wound exudates of pressure sore ulcers were measured to determine the beneficial effect of ORC/collagen matrix treatment compared with control treatment with a foam dressing. A total of 33 patients with pressure sores were enrolled in the study and were followed up for 12 weeks after treatment. Ten control patients were treated with a foam hydropolymer dressing (TIELLE ® , Systagenix), and the remaining 23 patients were treated with ORC/collagen matrix plus the foam dressing (TIELLE ® , Systagenix) on top. Wound assessments were carried out over 12 weeks on a weekly basis, with dressing changes twice a week. Ulcers were photographed and wound exudates were collected on admission and at days 5, 14 and then every 14 days to provide a visual record of any changes in appearance of the ulcer and healing rate and for biochemical analysis of the wound. The levels and activity of elastase and plasmin were measured in wound exudates. Statistical analysis was performed using ANOVA and Bonferroni's post hoc test with P-values <0·05 considered to be significant. Compared with controls, ORC/collagen matrix-treated pressure sore wounds showed a significant faster healing rate, which positively correlated with a decreased activity of elastase and plasmin in wound exudates. No signs of infection or intolerance to the ORC/collagen matrix were observed. © 2015 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  15. A randomised controlled trial of the effectiveness of soft silicone multi-layered foam dressings in the prevention of sacral and heel pressure ulcers in trauma and critically ill patients: the border trial.

    PubMed

    Santamaria, Nick; Gerdtz, Marie; Sage, Sarah; McCann, Jane; Freeman, Amy; Vassiliou, Theresa; De Vincentis, Stephanie; Ng, Ai Wei; Manias, Elizabeth; Liu, Wei; Knott, Jonathan

    2015-06-01

    The prevention of hospital acquired pressure ulcers in critically ill patients remains a significant clinical challenge. The aim of this trial was to investigate the effectiveness of multi-layered soft silicone foam dressings in preventing intensive care unit (ICU) pressure ulcers when applied in the emergency department to 440 trauma and critically ill patients. Intervention group patients (n = 219) had Mepilex(®) Border Sacrum and Mepilex(®) Heel dressings applied in the emergency department and maintained throughout their ICU stay. Results revealed that there were significantly fewer patients with pressure ulcers in the intervention group compared to the control group (5 versus 20, P = 0·001). This represented a 10% difference in incidence between the groups (3·1% versus 13·1%) and a number needed to treat of ten patients to prevent one pressure ulcer. Overall there were fewer sacral (2 versus 8, P = 0·05) and heel pressure ulcers (5 versus 19, P = 0·002) and pressure injuries overall (7 versus 27, P = 0·002) in interventions than in controls. The time to injury survival analysis indicated that intervention group patients had a hazard ratio of 0·19 (P = 0·002) compared to control group patients. We conclude that multi-layered soft silicone foam dressings are effective in preventing pressure ulcers in critically ill patients when applied in the emergency department prior to ICU transfer. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  16. The Effect of Offloading Heels on Sacral Pressure.

    PubMed

    Al-Majid, Sadeeka; Vuncanon, Barbara; Carlson, Nika; Rakovski, Cyril

    2017-09-01

    Offloading a patient's heels during supine surgical procedures is a common practice to prevent heel pressure injuries. This practice may increase sacral pressure and jeopardize sacral skin integrity, but prophylactic dressings may help protect sacral skin. The purpose of this study was to examine the effects of offloading the heels and of multilayered silicone foam dressings on sacral pressure. We measured the sacral pressure of 50 healthy volunteers using a pressure-mapping system under four conditions: heels not offloaded and sacral dressing applied, heels offloaded and dressing applied, heels not offloaded and no dressing, and heels offloaded and no dressing. We used linear mixed-effects modeling to compare the effects of these conditions on sacral pressure. Offloading the heels significantly increased sacral pressure (P < .001), whereas the dressing had no effect on sacral pressure (P = .49). Offloading a patient's heels may increase the risk of sacral pressure injuries. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  17. Use of Ovine-based Collagen Extracellular Matrix and Gentian Violet/Methylene Blue Antibacterial Foam Dressings to Help Improve Clinical Outcomes in Lower Extremity Wounds: A Retrospective Cohort Study.

    PubMed

    Lullove, Eric J

    2017-04-01

    Dressings that provide broad spectrum metalloprotease reduction along with inherent aspects of an extracellular matrix may contribute to improved wound healing outcomes and shorter treatment times. The author performed a retrospective case series analysis to determine the clinical outcomes of regular debridement with the use of ovine-based collagen extracellular matrix dressings and gentian violet/methylene blue polyurethane antibacterial foam dressings in treating 53 patients with 53 chronic lower extremity wounds (diabetic foot ulcers [DFUs], venous leg ulcers, and heel pressure ulcers). Patients were treated twice weekly in an outpatient clinic for the first 4 weeks and weekly thereafter until closure. Average body mass index (BMI) for the study population was 28.3, and the average patient age was 75.9 years. Mean percent wound surface area reduction at 4, 8, and 12 weeks was 38.5%, 73.3%, and 91.3%, respectively. Average time to closure for all wounds was 10.6 weeks (range, 5-24 weeks). All wounds were 100% reepithelialized by week 20 except 1 DFU that reepithelialized at week 24. The average cost of care for a single wound episode (from presentation to closure) was $2749.49. Results of this analysis showed that the healing of chronic wounds in this series could be achieved at a reasonable cost with regular debridement and a collagen matrix dressing regimen, even in patients of advanced age and above average BMI as well as in wounds that did not achieve > 40% wound surface area reduction at 4 weeks.

  18. Polymer-Reinforced, Non-Brittle, Lightweight Cryogenic Insulation

    NASA Technical Reports Server (NTRS)

    Hess, David M.

    2013-01-01

    The primary application for cryogenic insulating foams will be fuel tank applications for fueling systems. It is crucial for this insulation to be incorporated into systems that survive vacuum and terrestrial environments. It is hypothesized that by forming an open-cell silica-reinforced polymer structure, the foam structures will exhibit the necessary strength to maintain shape. This will, in turn, maintain the insulating capabilities of the foam insulation. Besides mechanical stability in the form of crush resistance, it is important for these insulating materials to exhibit water penetration resistance. Hydrocarbon-terminated foam surfaces were implemented to impart hydrophobic functionality that apparently limits moisture penetration through the foam. During the freezing process, water accumulates on the surfaces of the foams. However, when hydrocarbon-terminated surfaces are present, water apparently beads and forms crystals, leading to less apparent accumulation. The object of this work is to develop inexpensive structural cryogenic insulation foam that has increased impact resistance for launch and ground-based cryogenic systems. Two parallel approaches will be pursued: a silica-polymer co-foaming technique and a post foam coating technique. Insulation characteristics, flexibility, and water uptake can be fine-tuned through the manipulation of the polyurethane foam scaffold. Silicate coatings for polyurethane foams and aerogel-impregnated polyurethane foams have been developed and tested. A highly porous aerogel-like material may be fabricated using a co-foam and coated foam techniques, and can insulate at liquid temperatures using the composite foam

  19. Melt impregnation as a post processing treatment for performance enhancement in high capacity 3D microporous tin-copper-nickel intermetallic anode for Li-ion battery supported by electrodeposited nickel scaffold: A structural study

    NASA Astrophysics Data System (ADS)

    Sengupta, Srijan; Patra, Arghya; Mitra, Arijit; Jena, Sambedan; Das, Karabi; Majumder, Subhasish Basu; Das, Siddhartha

    2018-05-01

    This paper communicates stabilization of a Sn anode by impregnating it within the porous framework of a Ni-scaffold. The impregnation is carried out by electrodeposition Sn on Ni-foam followed by heating at 300 °C for 1 h. The Ni-foam was also electrodeposited on a Cu foil prior to deposition of Sn. The melting step leads to the formation of Nisbnd Sn and Cusbnd Sn intermetallics within pores of the Ni-scaffold. Snsbnd Cu/Ni intermetallics lithiate following the active-inactive strategy in which the inactive Cu/Ni buffers the volume expansion while Sn lithiates. Furthermore, this entire process takes place within Ni-scaffold which resists material pulverization and delamination and provide better electronic pathway for charge transfer. This active-inactive Sn:Snsbnd Cu/Ni intermetallic within a protected Ni-scaffold assembly results in 100th cycle discharge capacity of 587.9 mA h/g at a rate of 500 mA/g (0.5 C), and superior rate capability delivering 463 mAh/g at a rate of 2 A/g (2 C) while retaining structural integrity as compared to pure Sn electrodeposited (without heat-treatment) on the nickel scaffold.

  20. N-Halamine Biocidal Materials with Superior Antimicrobial Efficacies for Wound Dressings.

    PubMed

    Demir, Buket; Broughton, Roy M; Qiao, Mingyu; Huang, Tung-Shi; Worley, S D

    2017-09-21

    This work demonstrated the successful application of N-halamine technology for wound dressings rendered antimicrobial by facile and inexpensive processes. Four N-halamine compounds, which possess different functional groups and chemistry, were synthesized. The N-halamine compounds, which contained oxidative chlorine, the source of antimicrobial activity, were impregnated into or coated onto standard non-antimicrobial wound dressings. N-halamine-employed wound dressings inactivated about 6 to 7 logs of Staphylococcus aureus and Pseudomonas aeruginosa bacteria in brief periods of contact time. Moreover, the N-halamine-modified wound dressings showed superior antimicrobial efficacies when compared to commercially available silver wound dressings. Zone of inhibition tests revealed that there was no significant leaching of the oxidative chlorine from the materials, and inactivation of bacteria occurred by direct contact. Shelf life stability tests showed that the dressings were stable to loss of oxidative chlorine when they were stored for 6 months in dark environmental conditions. They also remained stable under florescent lighting for up to 2 months of storage. They could be stored in opaque packaging to improve their shelf life stabilities. In vitro skin irritation testing was performed using a three-dimensional human reconstructed tissue model (EpiDerm™). No potential skin irritation was observed. In vitro cytocompatibility was also evaluated. These results indicate that N-halamine wound dressings potentially can be employed to prevent infections, while at the same time improving the healing process by eliminating undesired bacterial growth.

  1. Foam-rubber stents for skin grafts.

    PubMed

    Larson, P O

    1990-09-01

    A variety of stents are used to immobilize skin grafts and to hold them firmly to the recipient site. Tie-down stents, the most common type, are constructed from bulky, sterile dressing and are overtied with suture material. These stents are often cumbersome to apply. As an alternative, stents made from foam-rubber pads (Reston, 3M Company, St. Paul, MN) were stapled over skin grafts. These stents could be applied quickly, and they maintain continuous, uniform pressure on the immobilized grafts.

  2. Evaluation of human amniotic membrane as a wound dressing for split-thickness skin-graft donor sites.

    PubMed

    Loeffelbein, Denys J; Rohleder, Nils H; Eddicks, Matthias; Baumann, Claudia M; Stoeckelhuber, Mechthild; Wolff, Klaus-D; Drecoll, Enken; Steinstraesser, Lars; Hennerbichler, Simone; Kesting, Marco R

    2014-01-01

    Human amniotic membrane (HAM) has been used as a biomaterial in various surgical procedures and exceeds some qualities of common materials. We evaluated HAM as wound dressing for split-thickness skin-graft (STSG) donor sites in a swine model (Part A) and a clinical trial (Part B). Part A: STSG donor sites in 4 piglets were treated with HAM or a clinically used conventional polyurethane (PU) foil (n = 8 each). Biopsies were taken on days 5, 7, 10, 20, 40, and 60 and investigated immunohistochemically for alpha-smooth muscle actin (αSMA: wound contraction marker), von Willebrand factor (vWF: angiogenesis), Ki-67 (cell proliferation), and laminin (basement membrane integrity). Part B: STSG donor sites in 45 adult patients (16 female/29 male) were treated with HAM covered by PU foam, solely by PU foam, or PU foil/paraffin gauze (n = 15 each). Part A revealed no difference in the rate of wound closure between groups. HAM showed improved esthetic results and inhibitory effects on cicatrization. Angioneogenesis was reduced, and basement membrane formation was accelerated in HAM group. Part B: no difference in re-epithelialization/infection rate was found. HAM caused less ichor exudation and less pruritus. HAM has no relevant advantage over conventional dressings but might be a cost-effective alternative.

  3. A randomized, controlled trial of negative pressure wound therapy of pressure ulcers via a novel polyurethane foam.

    PubMed

    Wagstaff, Marcus James Dermot; Driver, Sara; Coghlan, Patrick; Greenwood, John Edward

    2014-01-01

    The objectives of the study were (1) to look for any local, clinically apparent response, within and around a debrided wound, to a novel biocompatible polyurethane foam during repeated, short-term implantation, and (2) to assess the material's efficacy as a negative pressure wound therapy (NPWT) interface compared with a widely used, commercially available foam. Twenty pressure ulcers in 18 patients underwent surgical debridement, then randomization to receive novel treatment or control foam as the wound interface for NPWT. Dressing changes every 2-3 days allowed qualitative wound assessment and quantitative measurement to compare outcomes. No adverse reaction was observed in any patient receiving the new foam. The new "novel foam" performed as a NPWT interface as effectively as the control "standard foam." In deep wounds, the new foam was easier to remove, fragmented less, and showed less retention than the control foam. No marginal in-growth occurred, making removal less traumatic and reducing bleeding from cavity wall granulations. The results support previous large animal studies, and independent ISO10993 testing, that the new foam is safe and biocompatible. Its efficacy as an NPWT interface, nontraumatic removal with low fragmentation and retention rate, favors the new material, especially in deep cavity wounds. © 2014 by the Wound Healing Society.

  4. Investigation of Industrial Polyurethane Foams Modified with Antimicrobial Copper Nanoparticles

    PubMed Central

    Sportelli, Maria Chiara; Picca, Rosaria Anna; Ronco, Roberto; Bonerba, Elisabetta; Tantillo, Giuseppina; Pollini, Mauro; Sannino, Alessandro; Valentini, Antonio; Cataldi, Tommaso R.I.; Cioffi, Nicola

    2016-01-01

    Antimicrobial copper nanoparticles (CuNPs) were electrosynthetized and applied to the controlled impregnation of industrial polyurethane foams used as padding in the textile production or as filters for air conditioning systems. CuNP-modified materials were investigated and characterized morphologically and spectroscopically, by means of Transmission Electron Microscopy (TEM), and X-ray Photoelectron Spectroscopy (XPS). The release of copper ions in solution was studied by Electro-Thermal Atomic Absorption Spectroscopy (ETAAS). Finally, the antimicrobial activity of freshly prepared, as well as aged samples—stored for two months—was demonstrated towards different target microorganisms. PMID:28773665

  5. Closed dressings after laser skin resurfacing.

    PubMed

    Newman, J P; Koch, R J; Goode, R L

    1998-07-01

    To evaluate the safety, efficacy, and patient acceptance of closed dressings after full facial resurfacing with the carbon dioxide laser. Prospective cohort of men and women undergoing full facial carbon dioxide laser resurfacing. Ambulatory surgical center at a university hospital. Forty consecutive patients randomized to 1 of 4 dressing groups. All patients underwent full facial resurfacing with a carbon dioxide laser system. One of 5 closed dressings (single- or 3-layer composite foam, plastic mesh, hydrogel, or polymer film) was placed immediately after the procedure. Closed dressings were changed on postoperative day 2 and removed on postoperative day 4. Objective postoperative criteria of erythema, scarring, reepithelialization, and surface irregularities were recorded and photodocumented. Comparisons were made among the closed dressing groups as well as with a group of historical control subjects treated with open dressings. The ease of application, office time for preparation and application, and cost of the individual dressings were collected. Patient characteristics of overall acceptance, comfort, and ease of maintenance were recorded with a visual analog scale. There were no complications of scarring, surface irregularities, or contact dermatitis from the application or maintenance of the closed dressings. There were no significant differences in the number of days of postoperative erythema or in the rate of facial reepithelialization among the groups. Most patients preferred not to continue with the closed dressings past 2 days. Positive features from the use of closed dressings included reduction in crust formation, decreased pruritus, decreased erythema, and decreased postoperative pain, compared with historical controls. Negative features included time in preparation and application of the dressings. Costs ranged from $9.79 to $50 per dressing change. Closed dressings are safe and offer benefits noted during the first 4 postoperative days. Patients can be expected to maintain a closed dressing for at least 24 hours but no longer than 4 days. The positive features of closed dressings and patient acceptance outweigh the cost and office time involved with their application and maintenance.

  6. Negative pressure wound therapy and external fixation device: a simple way to seal the dressing.

    PubMed

    Bulla, Antonio; Farace, Francesco; Uzel, André-Pierre; Casoli, Vincent

    2014-07-01

    Negative pressure therapy is widely applied to treat lower limb trauma. However, sealing a negative pressure dressing in the presence of an external fixation device may be difficult and time consuming. Therefore, screws, pins, wires, etc, may preclude the vacuum, preventing the plastic drape to perfectly adhere to the foam. To maintain the vacuum, we tried to prevent air leaking around the screws putting bone wax at the junction between the pins and the plastic drape. This solution, in our hands, avoids air leakage and helps maintain vacuum in a fast and inexpensive way.

  7. Honeycomb-laminate composite structure

    NASA Technical Reports Server (NTRS)

    Gilwee, W. J., Jr.; Parker, J. A. (Inventor)

    1977-01-01

    A honeycomb-laminate composite structure was comprised of: (1) a cellular core of a polyquinoxaline foam in a honeycomb structure, and (2) a layer of a noncombustible fibrous material impregnated with a polyimide resin laminated on the cellular core. A process for producing the honeycomb-laminate composite structure and articles containing the honeycomb-laminate composite structure is described.

  8. Development of a protective decorative fire resistant low smoke emitting, thermally stable coating material

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The development of suitable electrocoatings and subsequent application to nonconductive substrates are discussed. Substrates investigated were plastics or resin-treated materials such as FX-resin (phenolic-type resin) impregnated fiberglass mat, polyphenylene sulfide, polyether sulfone and polyimide-impregnated unidirectional fiberglass. Efforts were aimed at formulating a fire-resistant, low smoke emitting, thermally stable, easily cleaned coating material. The coating is to be used for covering substrate panels, such as aluminum, silicate foam, polymeric structural entities, etc., all of which are applied in the aircraft cabin interior and thus subject to the spillages, scuffing, spotting and the general contaminants which prevail in aircraft passenger compartments.

  9. Comparison of Negative Pressure Wound Therapy and Silver-Coated Foam Dressings in Open Wound Treatment in Dogs: A Prospective Controlled Clinical Trial.

    PubMed

    Nolff, Mirja C; Albert, Rebecca; Reese, Sven; Meyer-Lindenberg, Andrea

    2018-06-11

     To evaluate negative pressure wound therapy (NPWT) for treatment of complicated wounds in dogs.  Prospective randomized clinical study MATERIALS AND METHODS:  Dogs ( n  = 26) undergoing open-wound treatment were randomly assigned to one of two groups: Group A ( n  = 13) NPWT; Group B ( n  = 13) silver-coated foam dressing. Pairs of patients were matched based on wound conformation, localization, and underlying cause and compared in terms of duration of previous treatment, development of wound size (wound planimetry), time to closure, bacterial bio-burden and complications. Wound dressing changes were performed every 3 days during the first 9 days of therapy for both groups. Statistical analysis was performed.  Pre-treatment signalment and bacterial status were comparable between groups. Total time to closure was significantly ( p  = 0.018) shorter in Group A (14.2 days) compared with Group B (28.6 days), and wound planimetry on days 3, 6 and 9 showed significant greater reduction in total wound area for Group A at all-time points ( p  < 0.05). Furthermore, wounds in Group A showed less progression of local infection than did wounds in Group B ( p  = 0.01).  NPWT-treated wounds showed faster closure, improved macro-deformation and less local signs of infection. Schattauer GmbH Stuttgart.

  10. Synthesis and characterization of biosheet impregnated with Macrotyloma uniflorum extract for burn/wound dressings.

    PubMed

    Muthukumar, Thangavelu; Senthil, Rethinam; Sastry, Thotapalli Parvathaleswara

    2013-02-01

    Developing biomaterials having wound healing properties within the search of a common man is the need of hour, particularly in developing and third world countries. Keeping this objective in view we have developed a wound dressing material, in sheet form, containing fish scale collagen (FSC) and physiologically clotted fibrin (PCF), both are by products of aqua food and meat industries respectively. To impart antimicrobial properties to the composite sheet, it was incorporated with Macrotyloma uniflorum plant extract (MPE). SEM pictures have shown that FSC:PCF:MPE composite has fibrous and porous surface which helps in transportation of oxygen as well as absorbing wound fluids and their evaporation. The biomaterials have shown 100% biocompatibility and the percentage cell viability was found to be above 89%. The FSC:PCF:MPE biocomposite film with required mechanical strength, biocompatibility and antimicrobial properties can be tried as a burn/wound dressing material. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Factory-Based Permethrin Impregnation of Uniforms: Residual Activity against Aedes aegypti and Ixodes ricinus in Battle Dress Uniforms Worn under Field Conditions, and Cross-Contamination during the Laundering and Storage Process

    DTIC Science & Technology

    2006-06-01

    fever, relapsing fever, scrub typhus , and visceral leishmaniasis were either principal or contributing factors affecting overall mortal- ity and...human health. In 26 of 52 retro- spectively analyzed wars from 480 BC to 2002 AD, vector-borne diseases like plague, louse-borne typhus , malaria, yellow

  12. A comparison between DACC with chlorhexidine acetate-soaked paraffin gauze and foam dressing for skin graft donor sites.

    PubMed

    Lee, Jun Won; Park, Seong Hoon; Suh, In Suck; Jeong, Hii Sun

    2018-01-02

    Retrograde infections often occur with excessive or incomplete drainage of exudate, or as a result of adherence of dressings to wounds. Dialkylcarbamoyl chloride (DACC) irreversibly binds to bacterial surfaces and physically removes bacteria when dressings are changed. Chlorhexidine acetate-soaked paraffin gauze provides a moist wound-healing environment. We hypothesise that when DACC is combined with chlorhexidine acetate-soaked paraffin gauze, wound healing times decrease. From January 2013 to June 2015, medical records were retrospectively evaluated in 60 patients who underwent split-thickness skin grafts (STSG). Patients were divided into two groups: a 'thick skin group' and a 'thin skin group'. These two groups were further subdivided into a control group, where conventional foam dressings were applied to wounds, and an experimental group, where chlorhexidine acetate-soaked paraffin gauze with DACC was applied (DACC group). We compared the wound healing time between these subgroups. Differences in infected wound healing times were also compared. The Mann-Whitney test was applied to compare wound healing times between groups. Epithelialisation duration was significantly shorter in the DACC group. The control group had longer wound healing times, regardless of wound size. In the thick skin group, the median healing duration was 12 days in the control subgroup, compared with 9.5 days in the DACC subgroup (p=0.049). In the thin skin subgroup, the median healing duration in the control group was 18 days, compared with 10 days in the DACC subgroup (p=0.013). Application of DACC and chlorhexidine acetate-soaked paraffin gauze to skin graft donor sites can shorten healing times and is effective in treating infected wounds.

  13. Gels as battery separators for soluble electrode cells

    NASA Technical Reports Server (NTRS)

    Sheibley, D. W.; Gahn, R. F. (Inventor)

    1977-01-01

    Gels are formed from silica powders and hydrochloric acid. The gels are then impregnated into a polymeric foam and the resultant sheet material is then used in applications where the transport of chloride ions is desired. Specifically disclosed is the utilization of the sheet in electrically rechargeable redox flow cells which find application in bulk power storage systems.

  14. Mepilex Ag: an antimicrobial, absorbent foam dressing with Safetac technology.

    PubMed

    Barrett, Simon

    This article examines the role of a unique dressing-Mepilex Ag--that incorporates the rapid and sustained antimicrobial action of ionic silver with the benefits of Safetac soft silicone adhesive technology. The combined attributes of each component of this dressing allow both the control of pain and infection to be achieved simultaneously. This dual approach to the management of wounds is of significance since the evidence suggests that wound infection and the release of pro-inflammatory modulators result in both local pain and delayed healing. In this respect the control and treatment of pain is as important as the treatment of infection itself. A review of the clinical evidence relating to Safetac technology clearly demonstrates that it can be used to prevent dressing-related trauma, minimize pain at dressing change, and control exudate when used on a wide range of wound types and skin injuries. In combination with silver, this technology has been shown in in-vitro studies to have an almost instant and sustainable antimicrobial effect on a broad range of pathogens associated with delayed healing. Finally, in small clinical and case studies, Mepilex Ag has been shown to control wound bioburden and improve healing rates.

  15. Spinal cord injury pressure ulcer treatment: an experience-based approach.

    PubMed

    Sunn, Gabriel

    2014-08-01

    Pressure ulcers continue to impact the lives of spinal cord injury patients severely. Pressure ulcers must be accurately staged according to National Pressure Ulcer Advisory recommendations before treatment design. The first priority in treatment of pressure ulcers is offloading. Intact skin ulcers may be treated with noncontact nonthermal low-frequency ultrasound. Superficial pressure ulcers may be treated with a combination of collagenase and foam dressings. Deeper pressure ulcers warrant negative-pressure wound therapy dressings along with biologic adjuncts to fill in wound depth. Discovery and treatment of osteomyelitis is a high priority when initially evaluating pressure ulcers. Surgical intervention must always be considered. Published by Elsevier Inc.

  16. Negative pressure wound therapy using polyvinyl alcohol foam to bolster full-thickness mesh skin grafts in dogs.

    PubMed

    Or, Matan; Van Goethem, Bart; Kitshoff, Adriaan; Koenraadt, Annika; Schwarzkopf, Ilona; Bosmans, Tim; de Rooster, Hilde

    2017-04-01

    To report the use of negative pressure wound therapy (NPWT) with polyvinyl alcohol (PVA) foam to bolster full-thickness mesh skin grafts in dogs. Retrospective case series. Client-owned dogs (n = 8). Full-thickness mesh skin graft was directly covered with PVA foam. NPWT was maintained for 5 days (in 1 or 2 cycles). Grafts were evaluated on days 2, 5, 10, 15, and 30 for graft appearance and graft take, granulation tissue formation, and complications. Firm attachment of the graft to the recipient bed was accomplished in 7 dogs with granulation tissue quickly filling the mesh holes, and graft take considered excellent. One dog had bandage complications after cessation of the NPWT, causing partial graft loss. The PVA foam did not adhere to the graft or damage the surrounding skin. The application of NPWT with a PVA foam after full-thickness mesh skin grafting in dogs provides an effective method for securing skin grafts, with good graft acceptance. PVA foam can be used as a primary dressing for skin grafts, obviating the need for other interposing materials to protect the graft and the surrounding skin. © 2017 The American College of Veterinary Surgeons.

  17. Randomized, noninferiority study between video versus hand ultrasound with wet foam dressing materials to simulate B-lines in lung ultrasound: A CONSORT-compliant article.

    PubMed

    Park, Eun Jung; Yoon, Young Tak; Hong, Chong Kun; Ha, Young Rock; Ahn, Jung Hwan

    2017-07-01

    This study evaluated the efficacy of a teaching method using simulated B-lines of hand ultrasound with a wet foam dressing material. This prospective, randomized, noninferiority study was conducted on emergency medical technician students without any relevant training in ultrasound. Following a lecture including simulated (SG) or real video clips (RG) of B-lines, a posttest was conducted and a retention test was performed after 2 months. The test consisted of questions about B-lines in 40 randomly mixed video clips (20 simulated and 20 real videos) with 4 answer scores (R-1 [the correct answer score for the real video clips] vs S-1 [the correct answer score for the simulated video clips] in the posttest, R-2 [the correct answer score for the real video clips] vs S-2 [the correct answer score for the simulated video clips] in the retention test). A total of 77 and 73 volunteers participated in the posttest (RG, 38; SG, 39) and retention test (RG, 36; SG, 37), respectively. There was no significant (P > .05) difference in scores of R-1, S-1, R-2, or S-2 between RG and SG. The mean score differences between RG and SG were -0.6 (95% confidence interval [CI]: -1.49 to 0.11) in R-1, -0.1 (95% CI: -1.04 to 0.86) in S-1, 0 (95% CI: -1.57 to 1.50) in R-2, and -0.2 (95% CI: -1.52 to 0.25) in S-2. The mean differences and 95% CIs for all parameters fell within the noninferiority margin of 2 points (10%). Simulated B-lines of hand ultrasound with a wet foam dressing material were not inferior to real B-lines. They were effective for teaching and simulations. The study was registered with the Clinical Trial Registry of Korea: https://cris.nih.go.kr/cris/index.jsp (KCT0002144).

  18. Comparison of DNA Damage and Apoptosis Induced By Silver Nanoparticle-containing Dressing Materials During Wound Healing.

    PubMed

    Choi, Young Suk; Gwak, Heui-Chul; Park, Jae Keun; Lim, Ji Yun; Yeo, Eui Dong; Park, Eunseok; Kim, Junyong; Lee, Young Koo

    2018-04-13

    Silver nanoparticle (AgNP)-containing dressings are used worldwide for the treatment of wounds; however, many studies have indicated that AgNPs are toxic to humans and cause cell death, primarily via apoptosis. In this study, the investigators compare the apoptotic effects of various AgNP dressing materials, with the hypothesis that nanosilver would be less toxic than ionic silver. For the in vivo experiments, Sprague-Dawley (SD) and streptozotocin (STZ)-induced diabetic rats were treated with 5 dressing materials: Aquacel Ag (product A, silver ion; ConvaTec, Berkshire, UK), Acticoat (product B, AgNP; Smith & Nephew, Fort Worth, TX), Medifoam Silver (product C, silver ion; Genewel Science Co Ltd, Seongnam, South Korea), PolyMem Silver (product D, AgNP; Ferris Mfg Corp, Fort Worth, TX), and Vaseline-impregnated dressing gauze (control; Unilever, London, UK). All treatments were applied 3 times per week. After 14 days of treatment, the SD and STZ rats were euthanized, and wound samples were examined for apoptosis. The analysis included immunohistochemistry, terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) staining, Western blotting, and reverse transcription polymerase chain reaction for a semiquantitative evaluation of apoptosis. The AgNP-containing dressing materials were more cytotoxic than the silver dressings. Compared with the AgNP dressing materials, no significant levels of apoptotic factors were observed in the silver dressing-treated wounds. The TUNEL staining showed that product C-dressed wounds contained the most apoptotic cells, while some apoptotic cells were observed in product B-dressed wounds. Moreover, apoptotic gene expression was altered, including a decline in B-cell lymphoma-2 and activation of caspase-3. This was most evident in wounds treated with product C. Interestingly, apoptotic gene expression was not induced in product A-treated wounds. Finally, product D had a relatively lower silver concentration and was less toxic than products A-C. Dressing materials containing AgNP have an antimicrobial effect. However, the authors observed that some AgNP dressings induced DNA damage and apoptosis. Although AgNP dressings did not cause significant acute apoptotic effects, they should be examined for cytotoxic effects in chronic wounds and should be used with caution when treating chronic wounds and those with low bacteria counts.

  19. Evaluation of conventional therapeutic methods versus maggot therapy in the evolution of healing of tegumental injuries in Wistar rats with and without diabetes mellitus.

    PubMed

    Masiero, Franciéle Souza; Thyssen, Patricia Jacqueline

    2016-06-01

    Larval therapy consists on the application of sterilized carrion flies larvae, reared in laboratory, on acute, chronic, and/or infected wounds in order to promote healing. Conventional methods for treating injuries include mechanical debridement or silver-based dressings; however, they are not always effective for wound healing. Larval therapy is a feasible and safe treatment for therapeutic application and, in many cases, the only and the most recommended alternative for difficult healing injuries. Thus, this study aimed to evaluate the competence of Cochliomyia macellaria F. (Diptera: Calliphoridae) as a suitable species for therapeutic application and evaluate time and effectiveness of the types of treatments most commonly used to treat integumental injuries. C. macellaria eggs were obtained from colonies established in laboratory and sterilized prior to application. Twenty-five larvae were applied for each centimeter squared of lesion. Lesions were induced in 24 Wistar rats; type 1 diabetes mellitus was induced in 12 of them. Animals were divided in four groups with three individuals each, being denominated: larval therapy, larval therapy associated with foam dressing with silver release, mechanical debridement with foam dressing silver and control group, without treatment. All treatments were applied once and held for 24 h. Medical application of larvae was found to be safe, as only dead tissue was removed, and efficient to accelerate healing process when compared to other treatments.

  20. Comparison of antimicrobial activity of selected, commercially available wound dressing materials.

    PubMed

    Szweda, Piotr; Gorczyca, Grzegorz; Tylingo, Robert

    2018-05-02

    The aim of our study was to examine the antimicrobial potential of eight selected, commercially available wound dressings containing different antimicrobial agents: silver, chlorhexidine acetate, povidone-iodine, and manuka honey. The materials were tested against four reference strains of bacteria: Staphylococcus aureus (PCM 2051), Staphylococcus epidermidis (PCM 2118), Pseudomonas aeruginosa (ATCC 27853), and Escherichia coli (K12), using the disc diffusion-like method and a time-killing assay. For both experiments, the highest activity against all four tested strains of bacteria was observed in the case of Mepilex Ag, which contains silver as an antibacterial agent. Incubation for four hours of a 10x10mm 2 piece of this material in 10ml cells suspension (concentration: 10 9 -10 10 CFU/ml) resulted in complete elimination of bacteria of all four strains tested. The same results were obtained for a povidone-iodine containing dressing, Inadine, though its activity was lower in the disc diffusion assay. Silvercel, Aquacel Ag and Melgisorb Ag, which also contain silver, also exhibited a satisfactory level of activity. In the case of Aquacel Ag, 24 hours' incubation resulted in complete elimination of the cells of both Gram-negative bacteria, Escherichia coli and Pseudomonas aeruginosa.The Escherichia coli cells were killed after only four hours' treatment. High effectiveness against Escherichia coli was also demonstrated for Silvercel. However, 24 hours' includation was required for complete elimination of the cells of this bacteria strain. High activity against all tested bacteria, but only in the disc diffusion assay, was observed for Algivon, which contains manuka honey. The Medisorb Silver Pad, containing silver, and Bactigras, which contains chlorhexidine acetate, revealed much lower antimicrobial activity, particularly noticeable in the time-killing assay. In addition, we also tested the anti-staphylococcal activity of a biopolymer material impregnated with lysostaphin. Results revealed that its activity against Staphylococcus aureus was comparable to the most active wound dressings impregnated with silver or inadine. Some important differences in the antimicrobial potential of investigated materials have been found. The presented results could be of interest to clinicians managing wounds.

  1. Development of highly open polyhedral networks from vitreous carbon for orthopaedic applications

    NASA Astrophysics Data System (ADS)

    Güiza-Argüello, V.; Bayona-Becerra, M.; Cruz-Orellana, S.; Córdoba-Tuta, E.

    2017-01-01

    Highly open polyhedral networks were fabricated using an economical and environmentally friendly template route. Recycled cellulose foams were impregnated with a sucrose resin and then pyrolyzed in order to produce reticulated vitreous carbon foams with morphological features that closely resemble trabecular bone. Also, cell sizes ~1mm were achieved, a trait that will allow the mechanical reinforcement of such scaffolds using a biomaterial coating without compromising the pore size that favors osteoblast cell infiltration and growth (200-500µm). Moreover, initial studies showed that carbonization conditions have an effect on the mechanical properties of the synthesized foams and, therefore, such process parameters could be further evaluated towards the enhancement of the mechanical resistance of the scaffolds. The materials developed here are visualized as the porous component of a synthetic bone graft with features that could help overcome the current limitations associated with the medical treatments used for bone defect repair.

  2. Development and characterization of a rechargeable carbon foam electrode containing nickel oxyhydroxide active mass

    NASA Astrophysics Data System (ADS)

    Chye, Matthew B.

    2011-12-01

    Batteries and asymmetric electrochemical capacitors using nickel-based positive electrodes can provide high currents due to their defect structure and low internal resistance. Nickel-based positive electrodes, therefore, are ideal for high current applications such as power tools and electric vehicles (EVs). The positive electrodes prepared in this research are monolithic graphitic foams electrochemically impregnated with nickel oxyhydroxide active mass and select additives that enhance electrode performance. Carbon foam is a good current collector due to its light-weight, porous, and graphitic nature, which give its good electrical properties and the ability to be used as a current collector. Replacing sintered nickel current collectors in nickel-based batteries with a low cost, readily available material, carbon foam, can reduce the mass of a rechargeable battery. The goal of this research has been to contribute to fundamental science through better understanding of optimizing the deposition and formation processes of the active mass onto carbon foams as well as investigating the active mass behavior under deposition, formation, and cycling conditions. Flooded cells and a PFA sealed asymmetric capacitor have been used. The effects of carbon foam surface pretreatments and how they affect the active material/carbon foam performance are demonstrated. Also the feasibility of this positive electrode as a component in nickel-based batteries, a Ni-Zn cells and an asymmetric capacitor pouch cell, is demonstrated.

  3. Organoselenium coating on cellulose inhibits the formation of biofilms by Pseudomonas aeruginosa and Staphylococcus aureus.

    PubMed

    Tran, Phat L; Hammond, Adrienne A; Mosley, Thomas; Cortez, Janette; Gray, Tracy; Colmer-Hamood, Jane A; Shashtri, Mayank; Spallholz, Julian E; Hamood, Abdul N; Reid, Ted W

    2009-06-01

    Among the most difficult bacterial infections encountered in treating patients are wound infections, which may occur in burn victims, patients with traumatic wounds, necrotic lesions in people with diabetes, and patients with surgical wounds. Within a wound, infecting bacteria frequently develop biofilms. Many current wound dressings are impregnated with antimicrobial agents, such as silver or antibiotics. Diffusion of the agent(s) from the dressing may damage or destroy nearby healthy tissue as well as compromise the effectiveness of the dressing. In contrast, the antimicrobial agent selenium can be covalently attached to the surfaces of a dressing, prolonging its effectiveness. We examined the effectiveness of an organoselenium coating on cellulose discs in inhibiting Pseudomonas aeruginosa and Staphylococcus aureus biofilm formation. Colony biofilm assays revealed that cellulose discs coated with organoselenium completely inhibited P. aeruginosa and S. aureus biofilm formation. Scanning electron microscopy of the cellulose discs confirmed these results. Additionally, the coating on the cellulose discs was stable and effective after a week of incubation in phosphate-buffered saline. These results demonstrate that 0.2% selenium in a coating on cellulose discs effectively inhibits bacterial attachment and biofilm formation and that, unlike other antimicrobial agents, longer periods of exposure to an aqueous environment do not compromise the effectiveness of the coating.

  4. Effectiveness of using a new polyurethane foam multi-layer dressing in the sacral area to prevent the onset of pressure ulcer in the elderly with hip fractures: A pragmatic randomised controlled trial.

    PubMed

    Forni, Cristiana; D'Alessandro, Fabio; Gallerani, Pina; Genco, Rossana; Bolzon, Andrea; Bombino, Caterina; Mini, Sandra; Rocchegiani, Laura; Notarnicola, Teresa; Vitulli, Arianna; Amodeo, Alfredo; Celli, Guglielmo; Taddia, Patrizia

    2018-06-01

    Hip fractures in the elderly are a serious problem for the health service due to the high rate of complications. One of these complications is pressure ulcers that, according to the literature, occur in 8.8% to 55% of patients and mainly arise in the sacral area. The present randomised controlled trial tests whether applying a new innovative multi-layer polyurethane foam dressing (ALLEVYN LIFE™), reduces the onset of pressure ulcers in the sacral area. From March to December 2016, 359 fragility hip fracture patients were randomly divided into 2 groups: 182 in the control group and 177 in the experimental group. Pressure ulcers occurred overall in 36 patients (10%): 8 patients (4.5%) in the experimental group compared to 28 (15.4%) in the control group: P = 0.001, relative risk 0.29 (95% CI 0.14-0.61) with NNT of 9 (95% CI 6-21). In the experimental group the onset of pressure ulcers occurred on average on the 6th day compared to the 4th day in the control group (HR 4.4). Using polyurethane foam is effective at reducing the rate of pressure ulcers in the sacrum in elderly patients with hip fracture. The adhesiveness of this device also enables costs to be kept down. © 2018 The Authors. International Wound Journal published by Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  5. Size selective isocyanate aerosols personal air sampling using porous plastic foams

    NASA Astrophysics Data System (ADS)

    Khanh Huynh, Cong; Duc, Trinh Vu

    2009-02-01

    As part of a European project (SMT4-CT96-2137), various European institutions specialized in occupational hygiene (BGIA, HSL, IOM, INRS, IST, Ambiente e Lavoro) have established a program of scientific collaboration to develop one or more prototypes of European personal samplers for the collection of simultaneous three dust fractions: inhalable, thoracic and respirable. These samplers based on existing sampling heads (IOM, GSP and cassettes) use Polyurethane Plastic Foam (PUF) according to their porosity to support sampling and separator size of the particles. In this study, the authors present an original application of size selective personal air sampling using chemical impregnated PUF to perform isocyanate aerosols capturing and derivatizing in industrial spray-painting shops.

  6. Assessment of Wound Therapy Systems.

    DTIC Science & Technology

    1983-10-06

    electrodes in vinyl foam (mfr: Healthco) (for potential measurements), sticky carbon-impregnated pads (commonly used * for transcutaneous electrical nerve...improved product is a conductive material, applied to the target surface as a liquid (in which an electrode can be embedded); this liquid material then gels... conducted with two grades of collagen hydrolysate (gelatins) which have been cross-linked in situ from water solu- tion. This work clearly shows that stable

  7. Centrifuge Testing of a Partially-Confined FC-72 Spray

    DTIC Science & Technology

    2006-11-01

    induced body forces. Heat transfer associated with closed - loop spray cooling will be affected by acceleration body forces, the extent of which is not...impingement cooling, spray cooling, heat pipes , loop heat pipes , carbon foam impregnated with phase-change materials, and combinations of the above...reduced gravity and elevated gravity experiments to help prove viability of pulsating heat pipes (PHPs) for space applications. The PHPs, filled

  8. Skin graft fixation in severe burns: use of topical negative pressure.

    PubMed

    Kamolz, L P; Lumenta, D B; Parvizi, D; Wiedner, M; Justich, I; Keck, M; Pfurtscheller, K; Schintler, M

    2014-09-30

    Over the last 50 years, the evolution of burn care has led to a significant decrease in mortality. The biggest impact on survival has been the change in the approach to burn surgery. Early excision and grafting has become a standard of care for the majority of patients with deep burns; the survival of a given patient suffering from major burns is invariably linked to the take rate and survival of skin grafts. The application of topical negative pressure (TNP) therapy devices has demonstrated improved graft take in comparison to conventional dressing methods alone. The aim of this study was to analyze the impact of TNP therapy on skin graft fixation in large burns. In all patients, we applied TNP dressings covering a %TBSA of >25. The following parameters were recorded and documented using BurnCase 3D: age, gender, %TBSA, burn depth, hospital length-of-stay, Baux score, survival, as well as duration and incidence of TNP dressings. After a burn depth adapted wound debridement, coverage was simultaneously performed using split-thickness skin grafts, which were fixed with staples and covered with fatty gauzes and TNP foam. The TNP foam was again fixed with staples to prevent displacement and finally covered with the supplied transparent adhesive film. A continuous subatmospheric pressure between 75-120 mm Hg was applied (VAC®, KCI, Vienna, Austria). The first dressing change was performed on day 4. Thirty-six out of 37 patients, suffering from full thickness burns, were discharged with complete wound closure; only one patient succumbed to their injuries. The overall skin graft take rate was over 95%. In conclusion, we consider that split thickness skin graft fixation by TNP is an efficient method in major burns, notably in areas with irregular wound surfaces or subject to movement (e.g. joint proximity), and is worth considering for the treatment of aged patients.

  9. Zinc impregnated cellulose nanocomposites: Synthesis, characterization and applications

    NASA Astrophysics Data System (ADS)

    Ali, Attarad; Ambreen, Sidra; Maqbool, Qaisar; Naz, Sania; Shams, Muhammad Fahad; Ahmad, Madiha; Phull, Abdul Rehman; Zia, Muhammad

    2016-11-01

    Nanocomposite materials have broad applicability due to synergistic effect of combined components. In present investigation, cellulose isolated from citrus peel waste is used as a supporting material; impregnation of zinc oxide nanoparticles via co-precipitation method. The characterization of nano composite is carried out through Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD) analysis, scanning electron microscopy (SEM) and Thermo-gravimetric analysis (TGA) resulting less than 10 μm cellulose fiber and approx. 50 nm ZnO NPs. Zinc oxide impregnated cellulose (ZnO-Cel) exhibited significant bacterial devastation property when compared to ZnO NPs or Cellulose via disc diffusion and colony forming unit methods. In addition, the ZnO-Cel exhibited significant total antioxidant, and minor DPPH free radical scavenging and total reducing power activities. The nano composite also showed time dependent increase in photocatalytic by effectively degrading methylene blue dye up to 69.5% under sunlight irradiation within 90 min. The results suggest effective utilization of cellulose obtained from citrus waste and synthesis of pharmacologically important nano-composites that can be exploited in wound dressing; defence against microbial attack and healing due to antioxidative property, furthermore can also be used for waste water treatment.

  10. Synthesis of Ag-NPs impregnated cellulose composite material: its possible role in wound healing and photocatalysis.

    PubMed

    Ali, Attarad; Haq, Ihsan Ul; Akhtar, Javeed; Sher, Muhammad; Ahmed, Naveed; Zia, Muhammad

    2017-06-01

    Cellulose is the natural biopolymer normally used as supporting agent with enhanced applicability and properties. In present study, cellulose isolated from citrus waste is used for silver nanoparticles (Ag-NPs) impregnation by a simple and reproducible method. The Ag-NPs fabricated cellulose (Ag-Cel) was characterised by powder X-rays diffraction, Fortier transform infrared spectroscopy and scanning electron microscopy. The thermal stability was studied by thermo-gravimetric analysis. The antibacterial activity performed by disc diffusion assay reveals good zone of inhibition against Staphylococcus aureus and Escherichia coli by Ag-Cel as compared Ag-NPs. The discs also displayed more than 90% reduction of S. aureus culture in broth within 150 min. The Ag-Cel discs also demonstrated minor 2,2-diphenyl 1-picryl-hydrazyl radical scavenging activity and total reducing power ability while moderate total antioxidant potential was observed. Ag-Cel effectively degrades methylene-blue dye up to 63.16% under sunlight irradiation in limited exposure time of 60 min. The Ag-NPs impregnated cellulose can be effectively used in wound dressing to prevent bacterial attack and scavenger of free radicals at wound site, and also as filters for bioremediation and wastewater purification.

  11. Synthesis of α-Fe2O3 and Fe-Mn Oxide Foams with Highly Tunable Magnetic Properties by the Replication Method from Polyurethane Templates

    PubMed Central

    Feng, Yuping; Fornell, Jordina; Zhang, Huiyan; Solsona, Pau; Barό, Maria Dolors; Suriñach, Santiago; Sort, Jordi

    2018-01-01

    Open cell foams consisting of Fe and Fe-Mn oxides are prepared from metallic Fe and Mn powder precursors by the replication method using porous polyurethane (PU) templates. First, reticulated PU templates are coated by slurry impregnation. The templates are then thermally removed at 260 °C and the debinded powders are sintered at 1000 °C under N2 atmosphere. The morphology, structure, and magnetic properties are studied by scanning electron microscopy, X-ray diffraction and vibrating sample magnetometry, respectively. The obtained Fe and Fe-Mn oxide foams possess both high surface area and homogeneous open-cell structure. Hematite (α-Fe2O3) foams are obtained from the metallic iron slurry independently of the N2 flow. In contrast, the microstructure of the FeMn-based oxide foams can be tailored by adjusting the N2 flow. While the main phases for a N2 flow rate of 180 L/h are α-Fe2O3 and FeMnO3, the predominant phase for high N2 flow rates (e.g., 650 L/h) is Fe2MnO4. Accordingly, a linear magnetization versus field behavior is observed for the hematite foams, while clear hysteresis loops are obtained for the Fe2MnO4 foams. Actually, the saturation magnetization of the foams containing Mn increases from 5 emu/g to 52 emu/g when the N2 flow rate (i.e., the amount of Fe2MnO4) is increased. The obtained foams are appealing for a wide range of applications, such as electromagnetic absorbers, catalysts supports, thermal and acoustic insulation systems or wirelessly magnetically-guided porous objects in fluids. PMID:29439450

  12. Synthesis of α-Fe₂O₃ and Fe-Mn Oxide Foams with Highly Tunable Magnetic Properties by the Replication Method from Polyurethane Templates.

    PubMed

    Feng, Yuping; Fornell, Jordina; Zhang, Huiyan; Solsona, Pau; Barό, Maria Dolors; Suriñach, Santiago; Pellicer, Eva; Sort, Jordi

    2018-02-11

    Open cell foams consisting of Fe and Fe-Mn oxides are prepared from metallic Fe and Mn powder precursors by the replication method using porous polyurethane (PU) templates. First, reticulated PU templates are coated by slurry impregnation. The templates are then thermally removed at 260 °C and the debinded powders are sintered at 1000 °C under N₂ atmosphere. The morphology, structure, and magnetic properties are studied by scanning electron microscopy, X-ray diffraction and vibrating sample magnetometry, respectively. The obtained Fe and Fe-Mn oxide foams possess both high surface area and homogeneous open-cell structure. Hematite (α-Fe₂O₃) foams are obtained from the metallic iron slurry independently of the N₂ flow. In contrast, the microstructure of the FeMn-based oxide foams can be tailored by adjusting the N₂ flow. While the main phases for a N₂ flow rate of 180 L/h are α-Fe₂O₃ and FeMnO₃, the predominant phase for high N₂ flow rates (e.g., 650 L/h) is Fe₂MnO₄. Accordingly, a linear magnetization versus field behavior is observed for the hematite foams, while clear hysteresis loops are obtained for the Fe₂MnO₄ foams. Actually, the saturation magnetization of the foams containing Mn increases from 5 emu/g to 52 emu/g when the N₂ flow rate (i.e., the amount of Fe₂MnO₄) is increased. The obtained foams are appealing for a wide range of applications, such as electromagnetic absorbers, catalysts supports, thermal and acoustic insulation systems or wirelessly magnetically-guided porous objects in fluids.

  13. Polypyrrole electrodes doped with sulfanilic acid azochromotrop for electrochemical supercapacitors

    NASA Astrophysics Data System (ADS)

    Chen, S.; Zhitomirsky, I.

    2013-12-01

    In this work we demonstrate the feasibility of deposition of polypyrrole (PPy) films by electropolymerization on stainless steel substrates and fabrication of PPy powders by chemical polymerization using sulfanilic acid azochromotrop (SPADNS) as a new anionic dopant. The problem of low adhesion of PPy films to stainless steel substrates is addressed by the use of SPADNS, which exhibits chelating properties, promoting film formation. The use of fine particles, prepared by the chemical polymerization method, allows impregnation of Ni foams and fabrication of porous electrodes with high materials loading for electrochemical supercapacitors (ES). PPy films and Ni foam based PPy electrodes show capacitive behaviour in Na2SO4 electrolyte. The electron microscopy studies, impedance spectroscopy data and analysis of the SPADNS structure provide an insight into the factors, controlling capacitive behaviour. The Ni foam based electrodes offer advantages of improved capacitive behaviour at high materials loadings and good cycling stability. The area normalized and volume normalized specific capacitances are as high as 5.43 F cm-2 and 93.6 F cm-3, respectively, for materials loading of 35.4 mg cm-2. The capacitance retention of Ni foam based electrodes is 91.5% after 1000 cycles. The Ni foam based PPy electrodes are promising for application in ES.

  14. Evaluation of Six Split-thickness Skin Graft Donor-site Dressing Materials in a Swine Model

    PubMed Central

    Masella, Pamela C.; Balent, Eric M.; Carlson, Terri L.; Lee, Karen W.

    2013-01-01

    Background: Numerous dressings for split-thickness skin graft donor sites are commercially available with no conclusive evidence-based consensus regarding the optimal dressing choice. This study was conducted to identify which of 5 commonly used materials promotes wound healing most effectively for use on split-thickness donor sites in comparison with our standard dressing, Xeroform (petrolatum gauze). Methods: Twenty-four partial-thickness wounds were created on the backs of 4 pigs using a dermatome. Wounds (n = 4 per dressing type per pig) were treated with Xeroform, Opsite (polyurethane film), Kaltostat ( calcium sodium alginate), DuoDERM (hydrocolloid), Aquacel (hydrofiber), and Mepilex (silicone foam). Full-thickness skin samples were excised at 3 or 5 days and evaluated histologically for reepithelialization and inflammation. Comparisons also included incidence of infection, ease of use, and cost analyses. Results: DuoDERM elicited the greatest percent reepithelialization (81%) and Mepilex the lowest (33%) after 3 days (P = 0.004). All dressings demonstrated complete reepithelialization except Mepilex (85%) at 5 days. There were no infections and inflammation was mild among all treatments. Mepilex was easiest to use, whereas Aquacel, Kaltostat, and Opsite were most difficult (P = 0.03). Xeroform was most cost-effective and Aquacel most expensive. Combined scoring revealed DuoDERM = Xeroform > Opsite = Mepilex > Kaltostat > Aquacel. Conclusions: DuoDERM and Xeroform were most effective overall. DuoDERM tended to outperform all dressings in reepithelialization at 3 days, while Xeroform was least expensive, easy to use, and demonstrated rapid reepithelialization. These findings suggest that Xeroform may be preferred for use on large donor-site areas. DuoDERM may be more appropriate for small donor sites when healing time is a priority. PMID:25289278

  15. Water Transport in Bicontinuous, Phase-Separated Membranes Made from Reactive Block Copolymers

    DTIC Science & Technology

    2014-12-01

    polyurethane foam impregnated with activated carbon, a design that allows perspiration to evaporate while chemical agents are adsorbed onto the activated... dispersed into a minimal volume (4–5 drops) of ethanol. The catalyst solution was then added to the polymer solution while stirring rapidly. The solution...substituted styrene monomer; one interior block with units of other styrene monomers which have been sulfonated; non- dispersible and solid in water

  16. Multifunctional Carbon Foams for Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Rogers, D. K.; Plucinski, J.

    2001-01-01

    Carbon foams produced by the controlled thermal decomposition of inexpensive coal extracts exhibit a combination of structural and thermal properties that make them attractive for aerospace applications. Their thermal conductivity can be tailored between 0.5 and 100 W/mK through precursor selection/modification and heat treatment conditions; thus, they can serve in either thermal protection or heat transfer systems such as heat exchangers. Because their structure is essentially a 3D random network of graphite-like members, they also can be considered low-cost, easily fabricated replacements for multi-directional structural carbon fiber preforms. Strengths of over 4000 psi in compression are common. Their density can be designed between 0.1 and 0.8 g/cc, and they can be impregnated with a variety of matrices or used, unfilled, in sandwich structures. These foams also exhibit intriguing electrochemical properties that offer potential in high-efficiency fuel cell and battery applications, mandrels and tooling for composite manufacture, ablative performance, and fire resistance. This paper presents the results of research conducted under NASA SBIR Topic 99.04.01, General Aviation Technology, supported from Langley Research Center. The potential of foam design through precursor selection, cell size and density control, density grading, and heat treatment is demonstrated.

  17. Influences of synthesis methods and modifier addition on the properties of Ni-based catalysts supported on reticulated ceramic foams

    NASA Astrophysics Data System (ADS)

    Nikolić, Vesna; Kamberović, Željko; Anđić, Zoran; Korać, Marija; Sokić, Miroslav; Maksimović, Vesna

    2014-08-01

    A method of synthesizing Ni-based catalysts supported on α-Al2O3-based foams was developed. The foams were impregnated with aqueous solutions of metal chlorides under an air atmosphere using an aerosol route. Separate procedures involved calcination to form oxides and drying to obtain chlorides on the foam surface. The synthesized samples were subsequently reduced with hydrogen. With respect to the Ni/Al2O3 catalysts, the chloride reduction route enabled the formation of a Ni coating without agglomerates or cracks. Further research included catalyst modification by the addition of Pd, Cu, and Fe. The influences of the additives on the degree of reduction and on the low-temperature reduction effectiveness (533 and 633 K) were examined and compared for the catalysts obtained from oxides and chlorides. Greater degrees of reduction were achieved with chlorides, whereas Pd was the most effective modifier among those investigated. The reduction process was nearly complete at 533 K in the sample that contained 0.1wt% Pd. A lower reduction temperature was utilized, and the calcination step was avoided, which may enhance the economical and technological aspects of the developed catalyst production method.

  18. Tissue Oxygenation and Negative-Pressure Wound Therapy When Applied to the Feet of Persons With Diabetes Mellitus: An Observational Study.

    PubMed

    Lee, Ye-Na; Lee, Jong Seok; Han, Seung-Kyu; Jung, Hye-Kyung

    Our group has reported that negative-pressure wound therapy (NPWT) decreases tissue oxygenation by 84% in the foot of diabetic patients because the pad of the connecting drainage tube and foam sponge of the NPWT system compress the wound bed. The purpose of this study was to determine whether an NPWT modified dressing application reduces tissue oxygenation in the feet of persons with diabetes mellitus. A prospective, clinical, observational study. We enrolled 30 patients with diabetic mellitus; their mean age was 63.9 ± 11.2 years (mean ± standard deviation). All were cared for at the diabetic wound center at an academic tertiary medical center in South Korea between 2014 and January 2015. Transcutaneous partial oxygen pressures (TcpO2) were measured to determine tissue oxygenation levels beneath modified NPWT dressings. A TcpO2 sensor was fixed at the tarsometatarsal area of the contralateral unwounded foot. A negative pressure of -125 mm Hg was applied until TcpO2 reached a plateau state; values were measured before, during, and after the modified NPWT. The Wilcoxon' and Mann-Whitney U tests were used to compare differences between these measurements. TcpO2 levels decreased by 26% during the modified NPWT. Mean TcpO2 values before, during, and after turning off the therapy were 54.3 ± 15.3 mm Hg, 41.6 ± 16.3 mm Hg, and 53.3 ± 15.6 mm Hg (P < .05), respectively. Applying NPWT without the pad of the connecting drainage tube significantly reduces the amount of tissue oxygenation loss beneath foam dressings on the skin of the foot dorsum in diabetic patients.

  19. Polyurethane foam containing rhEGF as a dressing material for healing diabetic wounds: Synthesis, characterization, in vitro and in vivo studies.

    PubMed

    Pyun, Do Gi; Choi, Hyun Jun; Yoon, Hyoung Soon; Thambi, Thavasyappan; Lee, Doo Sung

    2015-11-01

    Diabetic wounds are a major health issue associated with diabetes mellitus. To surmount this issue, we developed polyurethane foams (PUFs) incorporating varying amounts of recombinant human epidermal growth factor (rhEGF) (rhEGF-PUFs) as a wound dressing for diabetic wounds. From electron microscopy images, it was found that the pore size of the rhEGF-PUFs surface (the wound contact layer) was less than 100μm, regardless of rhEGF content. The release of rhEGF from the PUFs was evaluated using an enzyme-linked immunosorbent assay. The result showed that the release of rhEGF was time and concentration dependent, i.e., the amount of released rhEGF significantly increased as the immersion time and the rhEGF content of the PUFs increased. In vitro cytotoxicity testing showed that rhEGF-PUFs increased the viability of HaCaT human keratinocytes and CCD986-sk human fibroblasts, which indicated that the incorporated rhEGF maintained its biological activity. In an in vitro scratch wound healing assay, the wound closure rate was faster in CCD986-sk human fibroblasts than in HaCaT human keratinocytes. Finally, the rhEGF-PUFs were evaluated as an in vivo treatment in a full-thickness wound model in diabetized Sprague-Dawley rats. The result indicated that compared with PUFs, rhEGF-PUFs accelerated wound healing by promoting wound contraction, re-epithelialization, collagen deposition and the formation of a skin appendage. These findings demonstrate that rhEGF-PUFs are a promising dressing for diabetic wounds. Copyright © 2015. Published by Elsevier B.V.

  20. A Soft Casting Technique for Managing Pediatric Hand and Foot Burns.

    PubMed

    Choi, Young Mee; Nederveld, Cindy; Campbell, Kristen; Moulton, Steven

    2018-04-04

    Hand and foot burns in children are difficult to dress. The authors have developed a soft casting technique to manage burns to these areas. The aim of this study is to report the outcomes using weekly dressing changes with a soft casting technique to manage pediatric hand and foot burns in the outpatient setting. A retrospective chart review was performed on children with burns to the hands or feet, who underwent dressing changes with a soft casting technique at the Children's Hospital Colorado Burn Center. Soft casting was performed by placing antibiotic ointment-impregnated nonadherent gauze over the burn wound(s), wrapping the extremity using rolled gauze, applying soft cast pad, plaster, soft cast tape, and an elastic bandage. This was changed weekly. Two hundred ninety-eight children with hand burns had a mean age of 16.8 ± 2 months. Two hundred forty-eight children had partial thickness burn injuries (83%), 50 had full thickness burn injuries (17%), and the mean total body surface area (TBSA) was 1 ± 2.4%. The mean time to heal was 10.1 ± 1.7 days for all subjects. Sixty-six children with foot burns were identified with a mean age of 24 ± 2.6 months. Forty-six children had partial thickness injuries (70%), 20 had full thickness burn injuries (30%), and the mean TBSA was 2.3 ± 2.9%. The mean time to heal was 14.1 ± 2.2 days for all subjects. Weekly dressing changes using a soft casting technique are effective for the outpatient management of pediatric hand and foot burns. This method avoids costly inpatient hospital care, reduces the number of painful dressing changes, and allows children to heal in their own environment.

  1. Evaluation of Amniotic Membrane Effectiveness in Skin Graft Donor Site Dressing in Burn Patients.

    PubMed

    Salehi, Seyed Hamid; As'adi, Kamran; Mousavi, Seyed Jaber; Shoar, Saeed

    2015-12-01

    Although the recipient site in burn wounds is dressed with universally accepted materials, the ideal management of split-thickness skin donor sites remains controversial. The aim of our study is to compare two methods of wound dressing in donor sites of split-thickness skin graft in patients undergoing burn wound reconstructive surgery. Forty-two consecutive patients with second- and third-degree burns with a total body surface area between 20 and 40 % were enrolled in this randomized clinical trial conducted in Motahari Burn Hospital in Tehran, Iran. In each patient, two anatomic areas with similar features were randomly selected as intervention and control donor sites. The intervention site was dressed with amniotic membrane, whereas the control site was treated with Vaseline-impregnated gauze. Wounds were examined daily by expert surgeons to measure the clinical outcomes including duration of healing, severity of pain, and infection rate. The mean ± SD age of patients was 31.17 ± 13.72 years; furthermore, burn percentage had a mean ± SD of 31.19 ± 10.56. The mean ± SD of patients' cooperation score was 1.6 ± 0.79 in the intervention group compared with 2.93 ± 0.71 in the control group, revealing a statistically significant difference (P < 0.05). Duration of wound healing was significantly shorter (P < 0.05) in the intervention group (17.61 ± 2.56 days) compared with the control group (21.16 ± 3.45 days). However, there was no significant difference in terms of wound infection rate between donor sites in the control and intervention groups (P > 0.05). Amniotic membrane as an alternative for dressing of skin graft donor sites provides significant benefits by increasing patients' comfort via diminishing the number of dressing changes and facilitating the process of wound healing.

  2. Prophylactic dressing application to reduce pressure ulcer formation in cardiac surgery patients.

    PubMed

    Brindle, C Tod; Wegelin, Jacob A

    2012-01-01

    The study was designed to determine if application of a self-adherent silicone border foam dressing would reduce pressure ulcer incidence when compared to standard preventive interventions among patients managed in a cardiac surgery intensive care unit (CSICU). One hundred consecutive patients in the CSICU at Virginia Commonwealth University Medical Center in Richmond participated in the study. Fifteen were subsequently excluded due to incomplete data or failure to remain in the CSICU for at least 48 hours. Of the 100 subjects consecutively enrolled, 56 subjects were assigned to the intervention group with attrition of 6 subjects (6/56), and 39 were assigned to the standard care comparison group with attrition of 4 subjects (4/39). Five study forms were lost and the group assignment of those subjects is unknown. Patients admitted to the CSICU were assigned to either standard treatment or an intervention group consisting of standard preventive care plus application of the silicone border foam dressing. The assignment of subjects to these groups was done in a nonrandom manner, via prestudy room designation (7 intervention rooms/7 standard practice rooms) and room availability on call from the operating room. The charge nurse and bed management staff were unaware of room designation, and staff did not know which group the subjects were assigned to until they admitted the patient and opened the bedside chart that indicated group assignment. Twenty-one covariates were compared between the 2 groups. A Cox proportional hazards model was computed to compare the hazard (risk per unit time) of developing a pressure ulcer between these groups. Propensity score covariate adjustment was performed to adjust for any imbalance between the groups. Nine pressure ulcers developed during the course of the study. Eight pressure ulcers developed in 4 out of 35 patients who received standard preventive care; 5 were classified as suspected deep tissue injuries and 3 were classified as stage II pressure ulcers. One pressure ulcer developed in 1 out of 50 patients in the intervention group; it was classified as suspected deep tissue injury. No statistically significant difference in any covariate was found between the groups (all P > .058). The group that received standard care had a hazard ratio of 3.6 in relation to the intervention group, but this difference was not statistically significant (P = .3). Pressure ulcer incidence was lower than anticipated over the study period for both groups. No statistically significant difference in pressure ulcer incidence between the intervention and control groups was found. A randomized controlled trial based on a power analysis is needed to more precisely determine the efficacy of a silicone border foam dressing for prevention of pressure ulcers in the intensive care unit.

  3. In situ synthesis of silver-nanoparticles/bacterial cellulose composites for slow-released antimicrobial wound dressing.

    PubMed

    Wu, Jian; Zheng, Yudong; Song, Wenhui; Luan, Jiabin; Wen, Xiaoxiao; Wu, Zhigu; Chen, Xiaohua; Wang, Qi; Guo, Shaolin

    2014-02-15

    Bacterial cellulose has attracted increasing attention as a novel wound dressing material, but it has no antimicrobial activity, which is one of critical skin-barrier functions in wound healing. To overcome such deficiency, we developed a novel method to synthesize and impregnate silver nanoparticles on to bacterial cellulose nanofibres (AgNP-BC). Uniform spherical silver nano-particles (10-30 nm) were generated and self-assembled on the surface of BC nano-fibers, forming a stable and evenly distributed Ag nanoparticles coated BC nanofiber. Such hybrid nanostructure prevented Ag nanoparticles from dropping off BC network and thus minimized the toxicity of nanoparticles. Regardless the slow Ag(+) release, AgNP-BC still exhibited significant antibacterial activities with more than 99% reductions in Escherichia coli, Staphylococcus aureus and Pseudomonas aeruginosa. Moreover, AgNP-BC allowed attachment and growth of epidermal cells with no cytotoxicity emerged. The results demonstrated that AgNP-BC could reduce inflammation and promote wound healing. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Carbon Cryogel and Carbon Paper-Based Silicon Composite Anode Materials for Lithium-Ion Batteries

    NASA Technical Reports Server (NTRS)

    Woodworth, James; Baldwin, Richard; Bennett, William

    2010-01-01

    A variety of materials are under investigation for use as anode materials in lithium-ion batteries, of which, the most promising are those containing silicon. 6 One such material is a composite formed via the dispersion of silicon in a resorcinol-formaldehyde (RF) gel followed by pyrolysis. Two silicon-carbon composite materials, carbon microspheres and nanofoams produced from nano-phase silicon impregnated RF gel precursors have been synthesized and investigated. Carbon microspheres are produced by forming the silicon-containing RF gel into microspheres whereas carbon nano-foams are produced by impregnating carbon fiber paper with the silicon containing RF gel to create a free standing electrode. 1-5 Both materials have demonstrated their ability to function as anodes and utilize the silicon present in the material. Stable reversible capacities above 400 mAh/g for the bulk material and above 1000 mAh/g of Si have been observed.

  5. Carbon Cryogel Silicon Composite Anode Materials for Lithium Ion Batteries

    NASA Technical Reports Server (NTRS)

    Woodworth James; Baldwin, Richard; Bennett, William

    2010-01-01

    A variety of materials are under investigation for use as anode materials in lithium-ion batteries, of which, the most promising are those containing silicon. 10 One such material is a composite formed via the dispersion of silicon in a resorcinol-formaldehyde (RF) gel followed by pyrolysis. Two silicon-carbon composite materials, carbon microspheres and nanofoams produced from nano-phase silicon impregnated RF gel precursors have been synthesized and investigated. Carbon microspheres are produced by forming the silicon-containing RF gel into microspheres whereas carbon nano-foams are produced by impregnating carbon fiber paper with the silicon containing RF gel to create a free standing electrode. 1-4,9 Both materials have demonstrated their ability to function as anodes and utilize the silicon present in the material. Stable reversible capacities above 400 mAh/g for the bulk material and above 1000 mAh/g of Si have been observed.

  6. Novel Use of Active Leptospermum Honey for Ringed Fixator Pin Site Care in Diabetic Charcot Deformity Patients.

    PubMed

    Lazarides, Alexander L; Hamid, Kamran S; Kerzner, Michael S

    2018-04-01

    Open reduction with external fixation (OREF) utilizing fine wire ringed fixators for correction of Charcot deformity has gained popularity over the past decade. Pin site infections are a well-documented complication of external fixation as well as a driver of escalating health care costs. We aimed to demonstrate the safety and efficacy of a novel method of pin site care utilizing active Leptospermum honey-impregnated dressings (MediHoney) in diabetic patients undergoing deformity correction with OREF. Twenty-one diabetic patients with Charcot deformities of the lower extremity were prospectively enrolled and followed for pin site complications following OREF for deformity correction. Active Leptospermum honey dressings were applied at metal-cutaneous interfaces at the end of the OREF procedure and replaced weekly for a total of 8 weeks. Patients were monitored for pin site infections from the time of surgery until external fixator removal. Sixteen consecutive patients receiving standard OREF for Charcot deformities were evaluated retrospectively to serve as a control group. Of the 21 enrolled patients, 19 underwent OREF and followed up throughout the study period. Treated patients had a mean age of 58.5 years and mean body mass index measuring 33.3 kg/m 2 as documented prior to surgery. The 15 patients with hemoglobin A1c labs drawn in the 3 months preceding surgery averaged 7.5. Fixators were removed at an average of 12.1 weeks after adequate bony healing. Of the 244 pin sites in 19 patients, 3 pin sites (1.2% of pins) in 2 patients (10.5% of patients) showed evidence of superficial infection. All infections resolved with oral antibiotics. Infection rates were significantly reduced when compared to the standard care control group. Pilot data in a prospectively collected case series demonstrate safety and efficacy of active Leptospermum honey-impregnated dressings when used for fine wire ringed fixator pin site care in diabetic Charcot deformity patients. Further investigation in the form of a prospective randomized controlled study is warranted to demonstrate the potential value of this novel intervention. Level IV.

  7. Antibiotics and antiseptics for venous leg ulcers.

    PubMed

    O'Meara, Susan; Al-Kurdi, Deyaa; Ologun, Yemisi; Ovington, Liza G; Martyn-St James, Marrissa; Richardson, Rachel

    2013-12-23

    Venous leg ulcers are a type of chronic wound affecting up to 1% of adults in developed countries at some point during their lives. Many of these wounds are colonised by bacteria or show signs of clinical infection. The presence of infection may delay ulcer healing. Two main strategies are used to prevent and treat clinical infection in venous leg ulcers: systemic antibiotics and topical antibiotics or antiseptics. The objective of this review was to determine the effects of systemic antibiotics and topical antibiotics and antiseptics on the healing of venous ulcers; review authors also examined the effects of these interventions on clinical infection, bacterial flora, bacterial resistance, ulcer recurrence, adverse effects, patient satisfaction, health-related quality of life and costs. In May 2013, for this second update, we searched the Cochrane Wounds Group Specialised Register (searched 24 May 2013); the Cochrane Central Register of Controlled Trials (CENTRAL 2013, Issue 4); Ovid MEDLINE (1948 to Week 3 May 2013); Ovid MEDLINE (In-Process & Other Non-indexed Citations, 22 May 2013); Ovid EMBASE (1980 to Week 20 2013); and EBSCO CINAHL (1982 to 17 May 2013). No language or publication date restrictions were applied. Randomised controlled trials (RCTs) recruiting people with venous leg ulceration, evaluating at least one systemic antibiotic, topical antibiotic or topical antiseptic that reported an objective assessment of wound healing (e.g. time to complete healing, frequency of complete healing, change in ulcer surface area) were eligible for inclusion. Selection decisions were made by two review authors while working independently. Information on the characteristics of participants, interventions and outcomes was recorded on a standardised data extraction form. In addition, aspects of trial methods were extracted, including randomisation, allocation concealment, blinding of participants and outcome assessors, incomplete outcome data and study group comparability at baseline. Data extraction and validity assessment were conducted by one review author and were checked by a second. Data were pooled when appropriate. Forty-five RCTs reporting 53 comparisons and recruiting a total of 4486 participants were included, Many RCTs were small, and most were at high or unclear risk of bias. Ulcer infection status at baseline and duration of follow-up varied across RCTs. Five RCTs reported eight comparisons of systemic antibiotics, and the remainder evaluated topical preparations: cadexomer iodine (11 RCTs reporting 12 comparisons); povidone-iodine (six RCTs reporting seven comparisons); peroxide-based preparations (four RCTs reporting four comparisons); honey-based preparations (two RCTs reporting two comparisons); silver-based preparations (12 RCTs reporting 13 comparisons); other topical antibiotics (three RCTs reporting five comparisons); and other topical antiseptics (two RCTs reporting two comparisons). Few RCTs provided a reliable estimate of time to healing; most reported the proportion of participants with complete healing during the trial period. Systemic antibioticsMore participants were healed when they were prescribed levamisole (normally used to treat roundworm infection) compared with placebo: risk ratio (RR) 1.31 (95% CI 1.06 to 1.62). No between-group differences were detected in terms of complete healing for other comparisons: antibiotics given according to antibiogram versus usual care; ciprofloxacin versus standard care/placebo; trimethoprim versus placebo; ciprofloxacin versus trimethoprim; and amoxicillin versus topical povidone-iodine. Topical antibiotics and antisepticsCadexomer iodine: more participants were healed when given cadexomer iodine compared with standard care. The pooled estimate from four RCTs for complete healing at four to 12 weeks was RR 2.17 (95% CI 1.30 to 3.60). No between-group differences in complete healing were detected when cadexomer iodine was compared with the following: hydrocolloid dressing; paraffin gauze dressing; dextranomer; and silver-impregnated dressings.Povidone iodine: no between-group differences in complete healing were detected when povidone-iodine was compared with the following: hydrocolloid; moist or foam dressings according to wound status; and growth factor. Time to healing estimates for povidone-iodine versus dextranomer, and for povidone-iodine versus hydrocolloid, were likely to be unreliable.Peroxide-based preparations: four RCTs reported findings in favour of peroxide-based preparations when compared with usual care for surrogate healing outcomes (change in ulcer area). There was no report of complete healing.Honey-based preparations: no between-group difference in time to healing or complete healing was detected for honey-based products when compared with usual care.Silver-based preparations: no between-group differences in complete healing were detected when 1% silver sulphadiazine ointment was compared with standard care/placebo and tripeptide copper complex; or when different brands of silver-impregnated dressings were compared; or when silver-impregnated dressings were compared with non-antimicrobial dressings.Other topical antibiotics: data from one RCT suggested that more participants healed at four weeks when treated with an enzymatic cleanser (a non-antibiotic preparation) compared with a chloramphenicol-containing ointment (additional active ingredients also included in the ointment): RR 0.13 (95% CI 0.02 to 0.99). No between-group differences in complete healing were detected for framycetin sulphate ointment versus enzymatic cleanser; chloramphenicol ointment versus framycetin sulphate ointment; mupirocin ointment versus vehicle; and topical antibiotics given according to antibiogram versus an herbal ointment.Other topical antiseptics: data from one RCT suggested that more participants receiving an antiseptic ointment (ethacridine lactate) had responsive ulcers (defined as > 20% reduction in area) at four weeks when compared with placebo: RR 1.45 (95% CI 1.21 to 1.73). Complete healing was not reported. No between-group difference was detected between chlorhexidine solution and usual care. At present, no evidence is available to support the routine use of systemic antibiotics in promoting healing of venous leg ulcers. However, the lack of reliable evidence means that it is not possible to recommend the discontinuation of any of the agents reviewed. In terms of topical preparations, some evidence supports the use of cadexomer iodine. Current evidence does not support the routine use of honey- or silver-based products. Further good quality research is required before definitive conclusions can be drawn about the effectiveness of povidone-iodine, peroxide-based preparations, ethacridine lactate, chloramphenicol, framycetin, mupirocin, ethacridine or chlorhexidine in healing venous leg ulceration. In light of the increasing problem of bacterial resistance to antibiotics, current prescribing guidelines recommend that antibacterial preparations should be used only in cases of clinical infection, not for bacterial colonisation.

  8. Antibiotics and antiseptics for venous leg ulcers.

    PubMed

    O'Meara, Susan; Al-Kurdi, Deyaa; Ologun, Yemisi; Ovington, Liza G; Martyn-St James, Marrissa; Richardson, Rachel

    2014-01-10

    Venous leg ulcers are a type of chronic wound affecting up to 1% of adults in developed countries at some point during their lives. Many of these wounds are colonised by bacteria or show signs of clinical infection. The presence of infection may delay ulcer healing. Two main strategies are used to prevent and treat clinical infection in venous leg ulcers: systemic antibiotics and topical antibiotics or antiseptics. The objective of this review was to determine the effects of systemic antibiotics and topical antibiotics and antiseptics on the healing of venous ulcers. In May 2013, for this second update, we searched the Cochrane Wounds Group Specialised Register (searched 24 May 2013); the Cochrane Central Register of Controlled Trials (CENTRAL 2013, Issue 4); Ovid MEDLINE (1948 to Week 3 May 2013); Ovid MEDLINE (In-Process & Other Non-indexed Citations, 22 May 2013); Ovid EMBASE (1980 to Week 20 2013); and EBSCO CINAHL (1982 to 17 May 2013). No language or publication date restrictions were applied. Randomised controlled trials (RCTs) recruiting people with venous leg ulceration, evaluating at least one systemic antibiotic, topical antibiotic or topical antiseptic that reported an objective assessment of wound healing (e.g. time to complete healing, frequency of complete healing, change in ulcer surface area) were eligible for inclusion. Selection decisions were made by two review authors while working independently. Information on the characteristics of participants, interventions and outcomes was recorded on a standardised data extraction form. In addition, aspects of trial methods were extracted, including randomisation, allocation concealment, blinding of participants and outcome assessors, incomplete outcome data and study group comparability at baseline. Data extraction and validity assessment were conducted by one review author and were checked by a second. Data were pooled when appropriate. Forty-five RCTs reporting 53 comparisons and recruiting a total of 4486 participants were included, Many RCTs were small, and most were at high or unclear risk of bias. Ulcer infection status at baseline and duration of follow-up varied across RCTs. Five RCTs reported eight comparisons of systemic antibiotics, and the remainder evaluated topical preparations: cadexomer iodine (11 RCTs reporting 12 comparisons); povidone-iodine (six RCTs reporting seven comparisons); peroxide-based preparations (four RCTs reporting four comparisons); honey-based preparations (two RCTs reporting two comparisons); silver-based preparations (12 RCTs reporting 13 comparisons); other topical antibiotics (three RCTs reporting five comparisons); and other topical antiseptics (two RCTs reporting two comparisons). Few RCTs provided a reliable estimate of time to healing; most reported the proportion of participants with complete healing during the trial period. Systemic antibioticsMore participants were healed when they were prescribed levamisole (normally used to treat roundworm infection) compared with placebo: risk ratio (RR) 1.31 (95% CI 1.06 to 1.62). No between-group differences were detected in terms of complete healing for other comparisons: antibiotics given according to antibiogram versus usual care; ciprofloxacin versus standard care/placebo; trimethoprim versus placebo; ciprofloxacin versus trimethoprim; and amoxicillin versus topical povidone-iodine. Topical antibiotics and antiseptics Cadexomer iodine: more participants were healed when given cadexomer iodine compared with standard care. The pooled estimate from four RCTs for complete healing at four to 12 weeks was RR 2.17 (95% CI 1.30 to 3.60). No between-group differences in complete healing were detected when cadexomer iodine was compared with the following: hydrocolloid dressing; paraffin gauze dressing; dextranomer; and silver-impregnated dressings.Povidone iodine: no between-group differences in complete healing were detected when povidone-iodine was compared with the following: hydrocolloid; moist or foam dressings according to wound status; and growth factor. Time to healing estimates for povidone-iodine versus dextranomer, and for povidone-iodine versus hydrocolloid, were likely to be unreliable.Peroxide-based preparations: four RCTs reported findings in favour of peroxide-based preparations when compared with usual care for surrogate healing outcomes (change in ulcer area). There was no report of complete healing.Honey-based preparations: no between-group difference in time to healing or complete healing was detected for honey-based products when compared with usual care.Silver-based preparations: no between-group differences in complete healing were detected when 1% silver sulphadiazine ointment was compared with standard care/placebo and tripeptide copper complex; or when different brands of silver-impregnated dressings were compared; or when silver-impregnated dressings were compared with non-antimicrobial dressings.Other topical antibiotics: data from one RCT suggested that more participants healed at four weeks when treated with an enzymatic cleanser (a non-antibiotic preparation) compared with a chloramphenicol-containing ointment (additional active ingredients also included in the ointment): RR 0.13 (95% CI 0.02 to 0.99). No between-group differences in complete healing were detected for framycetin sulphate ointment versus enzymatic cleanser; chloramphenicol ointment versus framycetin sulphate ointment; mupirocin ointment versus vehicle; and topical antibiotics given according to antibiogram versus an herbal ointment.Other topical antiseptics: data from one RCT suggested that more participants receiving an antiseptic ointment (ethacridine lactate) had responsive ulcers (defined as > 20% reduction in area) at four weeks when compared with placebo: RR 1.45 (95% CI 1.21 to 1.73). Complete healing was not reported. No between-group difference was detected between chlorhexidine solution and usual care. At present, no evidence is available to support the routine use of systemic antibiotics in promoting healing of venous leg ulcers. However, the lack of reliable evidence means that it is not possible to recommend the discontinuation of any of the agents reviewed. In terms of topical preparations, some evidence supports the use of cadexomer iodine. Current evidence does not support the routine use of honey- or silver-based products. Further good quality research is required before definitive conclusions can be drawn about the effectiveness of povidone-iodine, peroxide-based preparations, ethacridine lactate, chloramphenicol, framycetin, mupirocin, ethacridine or chlorhexidine in healing venous leg ulceration. In light of the increasing problem of bacterial resistance to antibiotics, current prescribing guidelines recommend that antibacterial preparations should be used only in cases of clinical infection, not for bacterial colonisation.

  9. The Application of Skin Adhesive to Maintain Seal in Negative Pressure Wound Therapy.

    PubMed

    Karadsheh, Murad J; Nelson, Josh; Wilcox, Richard

    2015-09-01

    Optimal wound healing in negative pressure wound therapy (NPWT) depends on a properly sealed vacuum system. Anatomically difficult wounds disrupt the adhesive dressing, resulting in air leaks that impair the integrity of this system. Several techniques have been used in previous reports to prevent air leaks, including the addition of skin adhesives (eg, Skin-Prep [Smith and Nephew, St. Petersburg, FL] or compound tincture of benzoin), hydrocolloid dressings, silicone, and stoma paste. The purpose of this case report is to demonstrate the effectiveness of using a cyanoacrylate tissue adhesive, dermaFLEX (FLEXCon, Spencer, MA), in maintaining an airtight, durable seal in NPWT. The authors present a patient with a difficult to manage anogenital wound where efforts to maintain an airtight seal in NPWT proved difficult. It was decided during the course of treatment to use the cyanoacrylate tissue adhesive to create an airtight, durable seal. The tissue adhesive was applied circumferentially to the skin surrounding the wound edge. After placement of vacuum-assisted closure foam over the wound, the adhesive dressing was applied with its edges overlapping the skin area where the tissue adhesive was applied. The size of the wound was visibly reduced at each dressing change. An airtight seal was consistently maintained for 3 days at a time, surviving the difficult environment of the wound and maximizing the life of each adhesive dressing. For wounds in anatomically challenging locations, the use of the tissue adhesive appears to be a safe and viable option in creating a durable seal in NPWT.

  10. Characterization of polyurethane foam (PUF) and sorbent impregnated PUF (SIP) disk passive air samplers for measuring organophosphate flame retardants.

    PubMed

    Abdollahi, Atousa; Eng, Anita; Jantunen, Liisa M; Ahrens, Lutz; Shoeib, Mahiba; Parnis, J Mark; Harner, Tom

    2017-01-01

    This study aimed to characterize the uptake of organophosphate esters (OPEs) by polyurethane foam (PUF) and sorbent-impregnated polyurethane foam (SIP) disk passive air samplers (PAS). Atmospheric OPE concentrations were monitored with high-volume active air samplers (HV-AAS) that were co-deployed with passive air samplers. Samples were analyzed for tris(2-chloroisopropyl) phosphate (TCIPP), tri(phenyl) phosphate (TPhP), tris(2-chloroethyl) phosphate (TCEP), and tris(2,3-dichloropropyl) phosphate (TDCIPP). The mean concentration of ∑OPEs in air was 2650 pg/m 3 for the HV-AAS. Sampling rates and the passive sampler medium (PSM)-air partition coefficient (K PSM-Air ) were calculated for individual OPEs. The average calculated sampling rates (R) for the four OPEs were 3.6 ± 1.2 and 4.2 ± 2.0 m 3 /day for the PUF and SIP disks, respectively, and within the range of the recommended default value of 4 ± 2 m 3 /day. Since most of the OPEs remained in the linear uptake phase during the study, COSMO-RS solvation theory and an oligomer-based model were used to estimate K PUF-Air for the OPEs. The estimated values of log K PUF-Air were 7.45 (TCIPP), 9.35 (TPhP), 8.44 (TCEP), and 9.67 (TDCIPP). Finally, four configurations of the PUF and SIP disks were tested by adjusting the distance of the gap opening between the upper and lower domes of the sampler housing: i.e. 2 cm, 1 cm, no gap and 1 cm overlap. The sampling rate did not differ significantly between these four configurations (p < 0.05). Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  11. Negative pressure wound therapy in orthopaedic surgery.

    PubMed

    Robert, N

    2017-02-01

    Negative pressure wound therapy (NPWT) consists in applying subatmospheric pressure to a wound that is sealed off by a specially designed dressing and connected by a tube to a suction pump and drainage collection system. Skin defects are extremely common in orthopaedic and trauma surgery. NPWT is valuable across a range of indications. Proven effects include an increase in blood flow, stimulation of angiogenesis, and a decrease in wound surface area. NPWT can be used to treat post-traumatic and surgical wounds, burns, and chronic wounds such as pressure sores and ulcers. The lower frequency of dressing changes with NPWT lightens the staff workload. The French high authority for health (HAS) has issued good practice guidelines for the use of NPWT in specific and limited indications. NPWT has benefited from the introduction of several technological improvements such as silicone interfaces, foam dressings with various densities and pore sizes, and irrigation systems. The result is greater adaptability to each specific situation. Nevertheless, NPWT is not appropriate in every case and cannot replace a necessary surgical procedure. The goal of this work is to review the principles, practical modalities, and indications of NPWT. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  12. Nanosilver–Silica Composite: Prolonged Antibacterial Effects and Bacterial Interaction Mechanisms for Wound Dressings

    PubMed Central

    Ge, Yanling; Palva, Airi; Nordström, Katrina

    2017-01-01

    Infected superficial wounds were traditionally controlled by topical antibiotics until the emergence of antibiotic-resistant bacteria. Silver (Ag) is a kernel for alternative antibacterial agents to fight this resistance quandary. The present study demonstrates a method for immobilizing small-sized (~5 nm) silver nanoparticles on silica matrix to form a nanosilver–silica (Ag–SiO2) composite and shows the prolonged antibacterial effects of the composite in vitro. The composite exhibited a rapid initial Ag release after 24 h and a slower leaching after 48 and 72 h and was effective against both methicillin-resistant Staphylococcus aureus (MRSA) and Escherichia coli (E. coli). Ultraviolet (UV)-irradiation was superior to filter-sterilization in retaining the antibacterial effects of the composite, through the higher remaining Ag concentration. A gauze, impregnated with the Ag–SiO2 composite, showed higher antibacterial effects against MRSA and E. coli than a commercial Ag-containing dressing, indicating a potential for the management and infection control of superficial wounds. Transmission and scanning transmission electron microscope analyses of the composite-treated MRSA revealed an interaction of the released silver ions with the bacterial cytoplasmic constituents, causing ultimately the loss of bacterial membranes. The present results indicate that the Ag–SiO2 composite, with prolonged antibacterial effects, is a promising candidate for wound dressing applications. PMID:28878170

  13. Integra as a Dermal Replacement in a Meshed Composite Skin Graft in a Rat Model: A One-Step Operative Procedure

    DTIC Science & Technology

    2002-01-01

    skin graft (MCSG) using Integra as a dermal template for a meshed split thickness autograft was developed in rats. The silicon layer of Integra was removed, the resulting dermal analogue was meshed (1:1.5), expanded, and placed on excised full thickness wound and covered with a meshed (1:1.5 or 1:6) split thickness autograft. Grafted wounds were dressed with BioBrane, Vaseline gauze, silver-impregnated nylon, or silver-nylon and direct current (SNDC). At scheduled intervals up to 3 months postgrafting, wounds were examined for epithelialization, collagen deposition and

  14. Micrometric BN powders used as catalyst support: influence of the precursor on the properties of the BN ceramic

    NASA Astrophysics Data System (ADS)

    Perdigon-Melon, José Antonio; Auroux, Aline; Guimon, Claude; Bonnetot, Bernard

    2004-02-01

    Thin powders and foams of boron nitride have been prepared from molecular precursors for use as noble metal supports in the catalytic conversion of methane. Different precursors originating from borazines have been tested. The best results were obtained using a precursor derived from trichloroborazine (TCB) which, after reacting with ammonia at room temperature and then thermolyzing up to 1800°C, led to BN powders with a specific area of more than 300 m 2 g -1 and a micrometric spherical texture. Comparable results were obtained using polyborazylene under similar conditions. Aminoborazine-derived precursors did not yield such high specific area ceramics but the BN microstructure resembled a foam with a crystallized skin and amorphous internal part. These differences were related to the chemical mechanism of the conversion of the precursor into BN. Polyhaloborazines and polyborazines yielded BN through gas-solid reactions whereas aminoborazine polymers could be kept waxy up to high temperatures, which favored the glassy foam. Catalysts composed of BN support and platinum have been prepared using two routes: from a mixture of precursor or by impregnation of a BN powder leading to very different catalysts.

  15. Durability of template-free Fe-N-C foams for electrochemical oxygen reduction in alkaline solution

    NASA Astrophysics Data System (ADS)

    Mufundirwa, Albert; Harrington, George F.; Smid, Břetislav; Cunning, Benjamin V.; Sasaki, Kazunari; Lyth, Stephen M.

    2018-01-01

    Due to the high cost and limited availability of platinum, the development of non-platinum-group metals (non-PGM) catalysts is of paramount importance. A promising alternative to Pt are Fe-N-C-based materials. Here we present the synthesis, characterization and electrochemistry of a template-free nitrogen-doped carbon foam, impregnated with iron. This low-cost and gram-scale method results in materials with micron-scale pore size and large surface area (1600 m2g-1). When applied as an oxygen reduction reaction (ORR) electrocatalyst in alkaline solution, the Fe-N-C foams display extremely high initial activity, slightly out-performing commercially available non-PGM catalysts (NCP-2000, Pajarito Powder). The load-cycle durability in alkaline solution is investigated, and the performance steadily degrades over 60,000 potential cycles, whilst the commercial catalyst is remarkably stable. The post-operation catalyst microstructure is elucidated by transmission electron microscopy (TEM), to provide insight into the degradation processes. The resulting images suggest that potential cycling leads to leaching of atomically dispersed Fe-N2/4 sites in all the catalysts, whereas encapsulated iron nanoparticles are protected.

  16. Preparation of foam-like carbon nanotubes/hydroxyapatite composite scaffolds with superparamagnetic properties

    NASA Astrophysics Data System (ADS)

    Lu, X. Y.; Qiu, T.; Wang, X. F.; Zhang, M.; Gao, X. L.; Li, R. X.; Lu, X.; Weng, J.

    2012-12-01

    In this paper, the foam-like composite scaffolds composed of hydroxyapatite (HA) and carbon nanotubes (CNTs) were prepared by a new method, where a polymer impregnating method was used for porous HA-based scaffold and a chemical vapor deposition (CVD) method was used for the growth of CNTs from the HA-based scaffold. The process produces the CNTs/HA scaffolds that have a foam-like structure with better mechanical property, better microstructure and a high degree of interconnection. A favorable pore size with big pores of 1-2 mm and small pores of 20-300 μm for osteoconduction and bone ingrowth is presented in these scaffolds. About 2 wt% multi-walled CNTs with the diameter of 60-100 nm are observed to be in situ grown from deficient nano-HA crystallites. Magnetic measurement exhibits these scaffolds are superparamagnetic with a saturation magnetization of 1.14 emu g-1 at a room temperature, benefiting the scaffolds to take up growth factors in vivo, stem cell or other bioactive molecules easily. This new type of CNTs/HA scaffolds is expected to have a promising applications in bone tissue engineering, targeted drug delivery system and other biomedical fields.

  17. Off-loading total contact cast in combination with hydrogel and foam dressing for management of diabetic plantar ulcer of the foot.

    PubMed

    Vaseenon, Tanawat; Thitiboonsuwan, Songwut; Cheewawattanachai, Chaiyarit; Pimchoo, Punngam; Phanphaisarn, Areerak

    2014-12-01

    The total contact cast is considered to be an effective method of off-loading a diabetic non-infected pressure ulcer. However complications have been reported in 1 to 15% of cases, e.g. prolonged healing of the ulcer. Debridement with modern dressings has been reported to be effective in promoting wound healing; however there have been few reported studies of the combination of modern dressings with the cast. To evaluate the effectiveness of a combination of treatments on healing rates in diabetic non-infected plantar ulcer of the foot. This retrospective study with prospective data collection was conducted between September 2010 and August 2012. Twenty diabetic patients with plantar neuropathic ulcer were treated using a combination of a contact cast plus hydrogel andfoam dressings. The size and location of the ulcer, ulcer healing, foot deformities and complications were evaluated. Of 21 ulcers, 20 (95.2%) healed completely in a mean time of 30.1 days (range 14 to 70 days). Healing times for forefoot and midfoot ulcers were 22.6 and 26.8 days, respectively, which is significantly shorter than the 51.7 days for heel ulcers. One patient who had an unhealed ulcer developed a severe infection two months after treatment, which necessitated below the knee amputation. There were three cases of recurrence of the ulcers after casting. Off-loading casting combined with modern dressings had a high rate of healing in short-term treatment of diabetic non-infected pressure ulcers. Recurrence of ulcers and new site abrasions were common complications; those complications may have been caused by association with bone deformity or improper footwear.

  18. Antiseptic with modern wound dressings in the treatment of venous leg ulcers: clinical and microbiological aspects.

    PubMed

    Sopata, M; Kucharzewski, M; Tomaszewska, E

    2016-08-01

    To assess the impact of a two-period treatment on the clinical condition, bacteriological changes and results of treatment of venous leg ulcers (VLU) using octenidine dihydrochloride. Patients with a VLU were recruited and treated with octenidine dihydrochloride for one month, after which they were randomised and treated with hydrocolloids or foam dressings. The wounds were clinically assessed for the amount of necrotic tissue, granulation tissue, epithelialisation, amount of exudate and pain level. During the first period, bacterial colonisation and antimicrobial efficacy of octenidine dihydrochloride were also evaluated. In the second period the efficacy of treatment, time of treatment and healing rate were investigated. In the group of 50 VLU patients, all wounds (100%) improved after the first treatment period. No clinical signs of infection were observed. Statistically significant changes were observed in all the clinical parameters studied in the treated groups of VLU patients, including reduction of necrotic tissue, the amount of exudate and of pain, as well as increased granulation and epithelialisation. In the second period including treatment with the two dressings, no differences were observed in treatment efficacy, time of treatment or healing rate. As used in this study, octenidine dihydrochloride proved to be effective and useful, changing the clinical condition of VLU, preparing the wound for future treatment with modern dressings. High microbicidal activity of octenidine was observed, both against Gram-negative and Gram-positive bacteria isolated from the ulcers. Octenidine dihydrochloride caused an eradication of multiresistant strains (88%) as well as of bacteria qualified as alert-pathogens (100%) in the treated wounds after four weeks. However, no differences in the effects, time or rate of healing of VLU with two dressings were found in the second period. No side effects or significant local intolerance reactions used for treatment were observed.

  19. Antibacterial Properties of Nonwoven Wound Dressings Coated with Manuka Honey or Methylglyoxal

    PubMed Central

    Bulman, Sophie E. L.; Carr, Chris; Russell, Stephen J.

    2017-01-01

    Manuka honey (MH) is used as an antibacterial agent in bioactive wound dressings via direct impregnation onto a suitable substrate. MH provides unique antibacterial activity when compared with conventional honeys, owing partly to one of its constituents, methylglyoxal (MGO). Aiming to investigate an antibiotic-free antimicrobial strategy, we studied the antibacterial activity of both MH and MGO (at equivalent MGO concentrations) when applied as a physical coating to a nonwoven fabric wound dressing. When physically coated on to a cellulosic hydroentangled nonwoven fabric, it was found that concentrations of 0.0054 mg cm−2 of MGO in the form of MH and MGO were sufficient to achieve a 100 colony forming unit % bacteria reduction against gram-positive Staphylococcus aureus and gram-negative Klebsiella pneumoniae, based on BS EN ISO 20743:2007. A 3- to 20-fold increase in MGO concentration (0.0170–0.1 mg cm−2) was required to facilitate a good antibacterial effect (based on BS EN ISO 20645:2004) in terms of zone of inhibition and lack of growth under the sample. The minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) was also assessed for MGO in liquid form against three prevalent wound and healthcare-associated pathogens, i.e., Staphylococcus aureus, gram-negative Pseudomonas aeruginosa and gram-positive Enterococcus faecalis. Other than the case of MGO-containing fabrics, solutions with much higher MGO concentrations (128 mg L−1–1024 mg L−1) were required to provide either a bacteriostatic or bactericidal effect. The results presented in this study therefore demonstrate the relevance of an MGO-based coating as an environmentally friendly strategy for the design of functional dressings with antibiotic-free antimicrobial chemistries. PMID:28813014

  20. Chitosan-based dressings loaded with neurotensin--an efficient strategy to improve early diabetic wound healing.

    PubMed

    Moura, Liane I F; Dias, Ana M A; Leal, Ermelindo C; Carvalho, Lina; de Sousa, Hermínio C; Carvalho, Eugénia

    2014-02-01

    One important complication of diabetes mellitus is chronic, non-healing diabetic foot ulcers (DFUs). This study aims to develop and use dressings based on chitosan derivatives for the sustained delivery of neurotensin (NT), a neuropeptide that acts as an inflammatory modulator in wound healing. Three different derivatives, namely N-carboxymethyl chitosan, 5-methyl pyrrolidinone chitosan (MPC) and N-succinyl chitosan, are presented as potential biomaterials for wound healing applications. Our results show that MPC has the best fluid handling capacity and delivery profile, also being non-toxic to Raw 264.7 and HaCaT cells. NT-loaded and non-loaded MPC dressings were applied to control/diabetic wounds to evaluate their in vitro/in vivo performance. The results show that the former induced more rapid healing (50% wound area reduction) in the early phases of wound healing in diabetic mice. A NT-loaded MPC foam also reduced expression of the inflammatory cytokine TNF-α (P<0.001) and decreased the amount of inflammatory infiltrate on day 3. On day 10 MMP-9 was reduced in diabetic skin (P<0.001), significantly increasing fibroblast migration and collagen (COL1A1, COL1A2 and COL3A1) expression and deposition. These results suggest that MPC-based dressings may work as an effective support for sustained NT release to reduce DFUs. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  1. Degradation of lindane and hexachlorobenzene in supercritical carbon dioxide using palladium nanoparticles stabilized in microcellular high-density polyethylene.

    PubMed

    Wu, Bei-Zen; Chen, GuanYu; Yak, HwaKwang; Liao, Weisheng; Chiu, KongHwa; Peng, Shie-Ming

    2016-06-01

    Palladium nanoparticles stabilized in microcellular high-density polyethylene prepared through supercritical foaming, supercritical impregnation, and H2 reduction are used for the hydrodechlorination of lindane and hexachlorobenzene in supercritical carbon dioxide below 100 °C. Both lindane and hexachlorobenzene can be almost 100% transformed to cyclohexane in 1 h. Reaction intermediates, such as lower chlorinated products or benzene, are not observed or exist in trace amount indicating that most of them may undergo reactions without leaving the metal surface. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Necrotizing fasciitis secondary to enterocutaneous fistula: three case reports.

    PubMed

    Gu, Guo-Li; Wang, Lin; Wei, Xue-Ming; Li, Ming; Zhang, Jie

    2014-06-28

    Necrotizing fasciitis (NF) is an uncommon, rapidly progressive, and potentially fatal infection of the superficial fascia and subcutaneous tissue. NF caused by an enterocutaneous fistula has special clinical characters compared with other types of NF. NF caused by enterocutaneous fistula may have more rapid progress and more severe consequences because of multiple germs infection and corrosion by digestive juices. We treated three cases of NF caused by postoperative enterocutaneous fistula since Jan 2007. We followed empirically the principle of eliminating anaerobic conditions of infection, bypassing or draining digestive juice from the fistula and changing dressings with moist exposed burn therapy impregnated with zinc/silver acetate. These three cases were eventually cured by debridement, antibiotics and wound management.

  3. Impact of non-adherent Ibuprofen foam dressing in the lives of patients with venous ulcers.

    PubMed

    Salomé, Geraldo Magela; Ferreira, Lydia Masako

    2017-01-01

    to evaluate pain in patients with lower limb venous ulcer who used non-adherent Ibuprofen foam dressing (IFD). we conducted a prospective study of patients with lower limb venous ulcers treated from April 2013 to August 2014. We used the Numerical Scale and McGill Pain Questionnaire, performing the assessments at the moment of inclusion of the patient in the study and every eight days thereafter, totaling five consultations. We divided the patients into two groups: 40 in the Study Group (SG), who were treated with IFD, and 40 in the Control Group (CG), treated with primary dressing, according to tissue type and exudate. at the first consultation, patients from both groups reported intense pain. On the fifth day, SG patients reported no pain and the majority of CG reported moderate pain. Regarding the McGill Pain Questionnaire, most patients of both groups reported sensations related to sensory, affective, evaluative and miscellaneous descriptors at the beginning of data collection; after the second assessment, there was slight improvement among the patients in the SG. After the third consultation, they no longer reported the mentioned descriptors. CG patients displayed all the sensations of these descriptors until the fifth visit. non-adherent Ibuprofen foam dressing is effective in reducing the pain of patients with venous ulcers. avaliar a dor em pacientes portadores de úlcera venosa de membros inferiores que utilizaram curativo de espuma não aderente com Ibuprofeno (CEI). estudo prospectivo de pacientes portadores de úlceras venosas de membros inferiores tratados no período de abril de 2013 a agosto de 2014. Foram utilizados os questionários Escala Numérica e Questionário de Dor de McGille, as avaliações eram feitas no momento da inclusão do paciente no estudo e a cada oito dias, totalizando cinco consultas. Os pacientes foram divididos em dois grupos: 40 no Grupo Estudo (GE), que foram tratados com CEI, e 40 no Grupo Controle (GC), tratados com curativo primário, conforme o tipo de tecido e exsudato. na primeira consulta os pacientes de ambos os grupos relataram dor intensa. No quinto dia os pacientes do GE relataram ausência de dor e a maioria do GC relatou dor moderada. Com relação ao Questionário de Dor de McGill, a maioria dos pacientes de ambos os grupos, no início da coleta de dados, relataram sensações relacionadas aos descritores sensorial, afetivo, avaliativo e miscelânea, sendo que entre os pacientes do GE houve discreta melhora após a segunda consulta. Após a terceira consulta já não referiram os descritores citados. Os pacientes do GC manifestaram todas as sensações desses descritores até quinta a consulta. o curativo de espuma não aderente com Ibuprofeno é eficaz na redução da dor de pacientes portadores de úlceras venosas.

  4. Prevention and treatment of skin lesions associated with non-invasive mechanical ventilation. Recommendations of experts.

    PubMed

    Raurell-Torredà, M; Romero-Collado, A; Rodríguez-Palma, M; Farrés-Tarafa, M; Martí, J D; Hurtado-Pardos, B; Peñarrubia-San Florencio, L; Saez-Paredes, P; Esquinas, A M

    In the last two decades, non-invasive mechanical ventilation (NIV) has been consolidated as an initial strategy for the management of respiratory failure in critical adult and paediatric patients. To identify risk factors and preventive strategies to reduce the incidence of skin lesions associated with clinical devices (LESADIC) related to NIV, as well as the most effective treatment for injuries that cannot be avoided. Review in the MEDLINE, CINAHL and Cochrane databases of studies published in the last 10years to reach consensus through an expert panel. Knowledge about how to measure correct mask size and protection of the skin with foam or hydrocolloids dressings are factors related to the incidence of LESADIC, as it conditions the degree of pressure-friction and shear that the interface exerts on the skin. The interface that causes fewer LESADIC and is better tolerated is the face mask. When there are injuries, the first thing is to remove the interface that causes pressure on damaged skin, recommending a Helmet ® hood as an alternative, treating the infection, managing the exudate and stimulating perilesional skin. The mask of choice is the facial, always using foam or hydrocolloid dressings on the nasal bridge. Evaluate the condition of the skin under the interface and harness every 4hours (recommended) and 11hours (maximum). Evaluate the rotation strategy of the interface at 24hours if the NIV is still needed on an ongoing basis. Copyright © 2017 Sociedad Española de Enfermería Intensiva y Unidades Coronarias (SEEIUC). Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Effects of ozone gas on skin flaps viability in rats: an experimental study.

    PubMed

    Güner, Mehmet Haşim; Görgülü, Tahsin; Olgun, Abdulkerim; Torun, Merve; Kargi, Eksal

    2016-10-01

    The main purpose of this study was to assess the effects of ozone gas on the viability of flaps for reconstruction and to determine the optimum application method. The antioxidant, immunomodulatory, and reperfusion effects of ozone gas have been previously assessed, and successful results have been reported. However, only one study has investigated the effect of ozone gas on flap viability. In the present study, it was hypothesised that the antioxidant and reperfusion effects of ozone gas would enhance flap viability. Forty female Wistar rats were randomly divided into four groups of 10 rats each. A cranial-based, 3 × 11 cm modified McFarlane flap including the panniculus carnosus was raised from the dorsum of a rat and re-sutured to its own bed using 3/0 sharp propylene. Group 1 (n = 10): no pharmacological agent was used after the operation. Group 2 (n = 10): vegetable (olive) oil group; vegetable-oil-impregnated gauze was used as a dressing for 7 days. Group 3 (n = 10): Vegetable (olive) oil with ozone peroxide group; vegetable oil with ozone peroxide-impregnated gauze was used as a dressing for 7 days. Group 4 (n = 10): Hemo-ozone therapy group; hemo-ozone therapy was applied rectally once every day for 7 days. All rats were sacrificed at the end of week 1 and assessed macroscopically and histopathologically. The proportion of substantive necrosis was less in group 4 than in the other three groups. Survival area ratios were better in groups 2 and 3 than in group 1; however, there was no significant difference between groups 2 and 3. No significant differences in the histopathological scores were observed among the groups. Ozone gas enhanced flap viability. No differences in flap viability were observed between the vegetable oil and vegetable oil with ozone peroxide groups. The greatest benefit ratios were found in the hemo-ozone therapy group.

  6. Lightweight nickel electrode for nickel hydrogen cells and batteries

    NASA Technical Reports Server (NTRS)

    Britton, D. L.

    1986-01-01

    The nickel electrode was identified as the heaviest component of the nickel hydrogen (NiH2) battery. The NASA Lewis Research Center is developing nickel electrodes for NiH2 battery devices which will be lighter in weight and have higher energy densities when cycled under a low Earth orbit regime at deep depths of discharge. Lightweight plaques are first exposed to 31 percent potassium hydroxide for 3 months to determine their suitability for use as electrode substrates from a chemical corrosion standpoint. Pore size distribution and porosity of the plaques are then measured. The lightweight plaques examined are nickel foam, nickel felt, nickel plastic and nickel plated graphite. Plaques are then electrochemically impregnated in an aqueous solution. Initial characterization tests of the impregnated plaques are performed at five discharge levels, C/2, 1.0 C, 1.37 C, 2.0C, and 2.74 C rates. Electrodes that passed the initial characterization screening test will be life cycle tested. Lightweight electrodes are approximately 30 to 50 percent lighter in weight than the sintered nickel electrode.

  7. Highly porous nanostructured copper foam fiber impregnated with an organic solvent for headspace liquid-phase microextraction.

    PubMed

    Saraji, Mohammad; Ghani, Milad; Rezaei, Behzad; Mokhtarianpour, Maryam

    2016-10-21

    A new headspace liquid-phase microextraction technique based on using a copper foam nanostructure substrate followed by gas chromatography-flame ionization detection was developed for the determination of volatile organic compounds in water and wastewater samples. The copper foam with highly porous nanostructured walls was fabricated on the surface of a copper wire by a rapid and facile electrochemical process and used as the extractant solvent holder. Propyl benzoate was immobilized in the pores of the copper foam coating and used for the microextraction of benzene, toluene, ethylbenzene and xylenes. The experimental parameters such as the type of organic solvent, desorption temperature, desorption time, salt concentration, sample temperature, equilibrium time and extraction time, were investigated and optimized. Under the optimum conditions, the method detection limit was between 0.06 and 0.25μgL -1 . The relative standard deviation of the method for the analytes at 4-8μgL -1 concentration level ranged from 7.9 to 11%. The fiber-to-fiber reproducibility for three fibers prepared under the same condition was 9.3-12%. The enrichment factor was in the range of 615-744. Different water samples were analyzed for the evaluation of the method in real sample analysis. Relative recoveries for spiked tap, river and wastewater samples were in the range of 85-94%. Finally, the extraction efficiency of the method was compared with those of headspace single drop microextraction and headspace SPME with the commercial fibers. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Advanced textile materials and biopolymers in wound management.

    PubMed

    Petrulyte, Salvinija

    2008-02-01

    New generation medical textiles are an important growing field with great expansion in wound management products. Virtually new products are coming but also well known materials with significantly improved properties using advanced technologies and new methods are in the centre of research which are highly technical, technological, functional, and effective oriented. The key qualities of fibres and dressings as wound care products include that they are bacteriostatic, anti-viral, fungistatic, non-toxic, high absorbent, non-allergic, breathable, haemostatic, biocompatible, and manipulatable to incorporate medications, also provide reasonable mechanical properties. Many advantages over traditional materials have products modified or blended with also based on alginate, chitin/chitosan, collagen, branan ferulate, carbon fibres. Textile structures used for modern wound dressings are of large variety: sliver, yarn, woven, non-woven, knitted, crochet, braided, embroidered, composite materials. Wound care also applies to materials like hydrogels, matrix (tissue engineering), films, hydrocolloids, foams. Specialized additives with special functions can be introduced in advanced wound dressings with the aim to absorb odours, provide strong antibacterial properties, smooth pain and relieve irritation. Because of unique properties as high surface area to volume ratio, film thinness, nano scale fibre diameter, porosity, light weight, nanofibres are used in wound care. The aim of this study is to outline and review the latest developments and advance in medical textiles and biopolymers for wound management providing the overview with generalized scope about novelties in products and properties.

  9. Economics of ingot slicing with an internal diameter saw for low-cost solar cells

    NASA Technical Reports Server (NTRS)

    Daud, T.; Liu, J. K.; Fiegl, G.

    1981-01-01

    Slicing of silicon ingots using diamond impregnated internal diameter blade saws has been a standard technology of the semiconductor industry. This paper describes work on improvements to this technology for 10 cm diameter ingot slicing. Ingot rotation, dynamic blade edge control with feedback, mechanized blade dressing and development of thinner blades are the approaches tried. A comparison of the results for wafering with and without ingot rotation is also made. A sensitivity analysis of the major cost elements in wafering is performed for 10 cm diameter ingot and extended to the 15 cm diameter ingot case. Various parameter values such as machine cost, feed rate and consumable materials cost are identified both for single and multiple ingot slicing.

  10. Necrotizing fasciitis secondary to enterocutaneous fistula: Three case reports

    PubMed Central

    Gu, Guo-Li; Wang, Lin; Wei, Xue-Ming; Li, Ming; Zhang, Jie

    2014-01-01

    Necrotizing fasciitis (NF) is an uncommon, rapidly progressive, and potentially fatal infection of the superficial fascia and subcutaneous tissue. NF caused by an enterocutaneous fistula has special clinical characters compared with other types of NF. NF caused by enterocutaneous fistula may have more rapid progress and more severe consequences because of multiple germs infection and corrosion by digestive juices. We treated three cases of NF caused by postoperative enterocutaneous fistula since Jan 2007. We followed empirically the principle of eliminating anaerobic conditions of infection, bypassing or draining digestive juice from the fistula and changing dressings with moist exposed burn therapy impregnated with zinc/silver acetate. These three cases were eventually cured by debridement, antibiotics and wound management. PMID:24976737

  11. Optimal treatment of partial thickness burns in children: a systematic review.

    PubMed

    Vloemans, A F P M; Hermans, M H E; van der Wal, M B A; Liebregts, J; Middelkoop, E

    2014-03-01

    A large part of the patient population of a burn centre consists of children, most of whom are younger than four years. The majority of these young children suffer from superficial and deep partial thickness scald burns that may easily deepen to full thickness burns. A proper wound therapy, that prevents infection and ensures a moist wound condition, might prevent the deterioration of the wound. Therefore, we performed a systematic review of wound management and dressing materials to select the best treatment option for children with burns. A search in Medline and Embase revealed 51 articles for a critical appraisal. The articles were divided into randomized controlled trials, cohort studies and a group of case-reports. Total appraisal did not differ much amongst the groups; the level of evidence was highest in the randomized controlled trials and lowest in the case-reports. In 16 out of 34 comparative studies, silver sulfadiazine or a silver sulfadiazine/chlorhexidine-gluconate combination was the standard of wound care treatment. The competitor dressing was Biobrane(®) in six studies and amnion membrane in three. Tulle gauze, or tulle gauze impregnated with an antibacterial addition were the standard of care treatment in seven studies. In general, membranous dressings like Biobrane(®) and amnion membrane performed better than the standard of care on epithelialization rate, length of hospital stay and pain for treatment of partial thickness burns in children. However, hardly any of the studies investigated long-term results like scar formation. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  12. A shape memory foam composite with enhanced fluid uptake and bactericidal properties as a hemostatic agent.

    PubMed

    Landsman, T L; Touchet, T; Hasan, S M; Smith, C; Russell, B; Rivera, J; Maitland, D J; Cosgriff-Hernandez, E

    2017-01-01

    Uncontrolled hemorrhage accounts for more than 30% of trauma deaths worldwide. Current hemostatic devices focus primarily on time to hemostasis, but prevention of bacterial infection is also critical for improving survival rates. In this study, we sought to improve on current devices used for hemorrhage control by combining the large volume-filling capabilities and rapid clotting of shape memory polymer (SMP) foams with the swelling capacity of hydrogels. In addition, a hydrogel composition was selected that readily complexes with elemental iodine to impart bactericidal properties to the device. The focus of this work was to verify that the advantages of each respective material (SMP foam and hydrogel) are retained when combined in a composite device. The iodine-doped hydrogel demonstrated an 80% reduction in bacteria viability when cultured with a high bioburden of Staphylococcus aureus. Hydrogel coating of the SMP foam increased fluid uptake by 19× over the uncoated SMP foam. The composite device retained the shape memory behavior of the foam with more than 15× volume expansion after being submerged in 37°C water for 15 min. Finally, the expansion force of the composite was tested to assess potential tissue damage within the wound during device expansion. Expansion forces did not exceed 0.6N, making tissue damage during device expansion unlikely, even when the expanded device diameter is substantially larger than the target wound site. Overall, the enhanced fluid uptake and bactericidal properties of the shape memory foam composite indicate its strong potential as a hemostatic agent to treat non-compressible wounds. No hemostatic device currently used in civilian and combat trauma situations satisfies all the desired criteria for an optimal hemostatic wound dressing. The research presented here sought to improve on current devices by combining the large volume-filling capabilities and rapid clotting of shape memory polymer (SMP) foams with the swelling capacity of hydrogels. In addition, a hydrogel composition was selected that readily complexes with elemental iodine to impart bactericidal properties to the device. The focus of this work was to verify that the advantages of each respective material are retained when combined into a composite device. This research opens the door to generating novel composites with a focus on both hemostasis, as well as wound healing and microbial prevention. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  13. Conversion of "Waste Plastic" into Photocatalytic Nanofoams for Environmental Remediation.

    PubMed

    de Assis, Geovania C; Skovroinski, Euzébio; Leite, Valderi D; Rodrigues, Marcelo O; Galembeck, André; Alves, Mary C F; Eastoe, Julian; de Oliveira, Rodrigo J

    2018-03-07

    Plastic debris is a major environmental concern, and to find effective ways to reuse polystyrene (PS) presents major challenges. Here, it is demonstrated that polystyrene foams impregnated with SnO 2 are easily generated from plastic debris and can be applied to photocatalytic degradation of dyes. SnO 2 nanoparticles were synthesized by a polymeric precursor method, yielding specific surface areas of 15 m 2 /g after heat treatment to 700 °C. Crystallinity, size, and shape of the SnO 2 particles were assessed by X-ray diffraction (XRD) and transmission electron microscopy (TEM), demonstrating the preparation of crystalline spherical nanoparticles with sizes around 20 nm. When incorporated into PS foams, which were generated using a thermally induced phase separation (TIPS) process, the specific surface area increased to 48 m 2 /g. These PS/SnO 2 nanofoams showed very good efficiency for photodegradation of rhodamine B, under UV irradiation, achieving up to 98.2% removal. In addition the PS/SnO 2 nanofoams are shown to retain photocatalytic activity for up to five reuse cycles.

  14. Dressings and topical agents for treating pressure ulcers.

    PubMed

    Westby, Maggie J; Dumville, Jo C; Soares, Marta O; Stubbs, Nikki; Norman, Gill

    2017-06-22

    Pressure ulcers, also known as bedsores, decubitus ulcers and pressure injuries, are localised areas of injury to the skin or the underlying tissue, or both. Dressings are widely used to treat pressure ulcers and promote healing, and there are many options to choose from including alginate, hydrocolloid and protease-modulating dressings. Topical agents have also been used as alternatives to dressings in order to promote healing.A clear and current overview of all the evidence is required to facilitate decision-making regarding the use of dressings or topical agents for the treatment of pressure ulcers. Such a review would ideally help people with pressure ulcers and health professionals assess the best treatment options. This review is a network meta-analysis (NMA) which assesses the probability of complete ulcer healing associated with alternative dressings and topical agents. To assess the effects of dressings and topical agents for healing pressure ulcers in any care setting. We aimed to examine this evidence base as a whole, determining probabilities that each treatment is the best, with full assessment of uncertainty and evidence quality. In July 2016 we searched the Cochrane Wounds Specialised Register; the Cochrane Central Register of Controlled Trials (CENTRAL); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid Embase and EBSCO CINAHL Plus. We also searched clinical trials registries for ongoing and unpublished studies, and scanned reference lists of relevant included studies as well as reviews, meta-analyses, guidelines and health technology reports to identify additional studies. There were no restrictions with respect to language, date of publication or study setting. Published or unpublished randomised controlled trials (RCTs) comparing the effects of at least one of the following interventions with any other intervention in the treatment of pressure ulcers (Stage 2 or above): any dressing, or any topical agent applied directly to an open pressure ulcer and left in situ. We excluded from this review dressings attached to external devices such as negative pressure wound therapies, skin grafts, growth factor treatments, platelet gels and larval therapy. Two review authors independently performed study selection, risk of bias assessment and data extraction. We conducted network meta-analysis using frequentist mega-regression methods for the efficacy outcome, probability of complete healing. We modelled the relative effectiveness of any two treatments as a function of each treatment relative to the reference treatment (saline gauze). We assumed that treatment effects were similar within dressings classes (e.g. hydrocolloid, foam). We present estimates of effect with their 95% confidence intervals for individual treatments compared with every other, and we report ranking probabilities for each intervention (probability of being the best, second best, etc treatment). We assessed the certainty (quality) of the body of evidence using GRADE for each network comparison and for the network as whole. We included 51 studies (2947 participants) in this review and carried out NMA in a network of linked interventions for the sole outcome of probability of complete healing. The network included 21 different interventions (13 dressings, 6 topical agents and 2 supplementary linking interventions) and was informed by 39 studies in 2127 participants, of whom 783 had completely healed wounds.We judged the network to be sparse: overall, there were relatively few participants, with few events, both for the number of interventions and the number of mixed treatment contrasts; most studies were small or very small. The consequence of this sparseness is high imprecision in the evidence, and this, coupled with the (mainly) high risk of bias in the studies informing the network, means that we judged the vast majority of the evidence to be of low or very low certainty. We have no confidence in the findings regarding the rank order of interventions in this review (very low-certainty evidence), but we report here a summary of results for some comparisons of interventions compared with saline gauze. We present here only the findings from evidence which we did not consider to be very low certainty, but these reported results should still be interpreted in the context of the very low certainty of the network as a whole.It is not clear whether regimens involving protease-modulating dressings increase the probability of pressure ulcer healing compared with saline gauze (risk ratio (RR) 1.65, 95% confidence interval (CI) 0.92 to 2.94) (moderate-certainty evidence: low risk of bias, downgraded for imprecision). This risk ratio of 1.65 corresponds to an absolute difference of 102 more people healed with protease modulating dressings per 1000 people treated than with saline gauze alone (95% CI 13 fewer to 302 more). It is unclear whether the following interventions increase the probability of healing compared with saline gauze (low-certainty evidence): collagenase ointment (RR 2.12, 95% CI 1.06 to 4.22); foam dressings (RR 1.52, 95% CI 1.03 to 2.26); basic wound contact dressings (RR 1.30, 95% CI 0.65 to 2.58) and polyvinylpyrrolidone plus zinc oxide (RR 1.31, 95% CI 0.37 to 4.62); the latter two interventions both had confidence intervals consistent with both a clinically important benefit and a clinically important harm, and the former two interventions each had high risk of bias as well as imprecision. A network meta-analysis (NMA) of data from 39 studies (evaluating 21 dressings and topical agents for pressure ulcers) is sparse and the evidence is of low or very low certainty (due mainly to risk of bias and imprecision). Consequently we are unable to determine which dressings or topical agents are the most likely to heal pressure ulcers, and it is generally unclear whether the treatments examined are more effective than saline gauze.More research is needed to determine whether particular dressings or topical agents improve the probability of healing of pressure ulcers. The NMA is uninformative regarding which interventions might best be included in a large trial, and it may be that research is directed towards prevention, leaving clinicians to decide which treatment to use on the basis of wound symptoms, clinical experience, patient preference and cost.

  15. Reduction in Wound Bioburden using a Silver-Loaded Dissolvable Microfilm Construct

    PubMed Central

    Herron, Maggie; Agarwal, Ankit; Kierski, Patricia R.; Calderon, Diego F.; Teixeira, Leandro B. C.; Schurr, Michael J.; Murphy, Christopher J.

    2014-01-01

    Silver is a widely used antimicrobial agent, yet when impregnated in macroscopic dressings, it stains wounds, can lead to tissue toxicity and can inhibit healing. Recently, we reported that polymeric nanofilms containing silver nanoparticles exhibit antimicrobial activity at loadings and release rates of silver that are 100x lower than conventional dressings. Here we report fabrication of composite microfilm constructs that provide a facile way to transfer the silver-loaded polymeric nanofilms onto wounds in vivo. The construct is fabricated from a silver nanoparticle-loaded polymeric nanofilm that is laminated with a micrometer-thick soluble film of polyvinylalcohol (PVA). When placed on a moist wound, the PVA dissolves, leaving the silver-loaded nanofilm immobilized on the wound-bed. In vitro, the immobilized nanofilms release <1 μg cm−2/day of silver over 30 days from skin-dermis and they kill 5 log10 CFUs of Staphylococcus aureus in 24 h. In mice, wounds inoculated with 105 CFU S. aureus presented up to 3 log10 less bacterial burden when treated with silver/nanofilms for 3 days, as compared to unmodified wounds. In uncontaminated wounds, silver/nanofilms allow normal and complete wound closure by re-epithelialization. We conclude that dissolvable microfilm constructs may overcome key limitations associated with current uses of silver in wound healing. PMID:24523027

  16. Technology for the production of Zero Q.I pitch from coal tar

    NASA Astrophysics Data System (ADS)

    Karthik, K.; Kumar, K. Rajesh; Rao, C. V. Nageswara; Kumar, B. Vinod; Murty, J. V. S.

    2013-06-01

    Zero Quinoline Insolubles (Q.I) pitch is a special type of pitch obtained from pre-treatment of coal tar, which is converted into pitch. This is used for impregnation of electrodes for improving the strength, electrical properties and also used as a pre-cursor for Mesophase pitch for producing Mesophase pitch based carbon fibers, carbon foam, and Meso carbon micro beads. This paper discusses the technology of Q.I separation from Coal Tar by using decantation of Coal Tar mixed with Heavy Creosote Oil (HC Oil) at different temperatures. By this method we were able to produce the Zero Q.I pitch with a Q.I value of 0.1%.

  17. The Haiti earthquake: the provision of wound care for mass casualties utilizing negative-pressure wound therapy.

    PubMed

    Gabriel, Allen; Gialich, Shelby; Kirk, Julie; Edwards, Sheriden; Beck, Brooke; Sorocéanu, Alexandra; Nelson, Scott; Gabriel, Cassie; Gupta, Subhas

    2011-10-01

    Many months after the devastating earthquake in January 2010, wounds remain a major disease burden in Haiti. Since January 2010, through the efforts of corporations, nonprofit charitable organizations, and medical professionals, advanced wound care techniques, including negative-pressure wound therapy (NPWT), have been introduced into the wound care regimens of various hospitals in Haiti. In June 2010, the authors completed their second volunteer trip at a Haitian hospital specializing in orthopedic wounds. The medical team was composed of a plastic surgeon, orthopedic surgeon, anesthesiologist, medical assistant, scrub technician, and registered nurse (specializing in plastic surgery and orthopedics). The authors' team supplied NPWT devices, reticulated open-cell foam dressings, and canisters donated by Kinetic Concepts, Inc, San Antonio, Texas, for use at the hospital. This report describes the medical challenges in postearthquake Haiti (including limb salvage and infection), benefits of adjunctive use of NPWT/reticulated open-cell foam, and current wound care status in a Haitian orthopedic hospital. The future role of NPWT in Haiti and during mass catastrophe in a least-developed country is also discussed.

  18. The Immediate and Delayed Post-Debridement Effects on Tissue Bacterial Wound Counts of Hypochlorous Acid Versus Saline Irrigation in Chronic Wounds.

    PubMed

    Hiebert, John M; Robson, Martin C

    2016-01-01

    Introduction: Wound debridement is considered essential in chronic wound management. Hypochlorous acid has been shown to be an effective agent in reducing wound bacterial counts in open wounds. Ultrasound-enabled wound debridement is an effective and efficient method of debridement. This study compared ultrasound irrigation with hypochlorous acid versus saline irrigation for wound debridement on pre- and postoperative wounds and determined regrowth of bacteria over 1 week period of time. Finally, the outcome of definitive wound closure of the clinically clean-appearing wounds was recorded. Methods: Seventeen consenting adult patients with chronic open wounds were randomly selected for study. The patients were randomly divided into the hypochlorous acid irrigation or saline irrigation group. All patients provided pre- and postoperative tissue samples for qualitative and quantitative bacteriology. For the time (7 days) between the debridement procedure and the definitive closure procedure, the wounds were dressed with a silver-impregnated dressing and a hydroconductive dressing. Results : Both types of irrigation in the ultrasonic system initially lowered the bacterial counts by 4 to 6 logs. However, by the time of definitive closure, the saline-irrigated wounds had bacterial counts back up to 10 5 whereas the hypochlorous acid-irrigated wounds remained at 10 2 or fewer. More than 80% of patients in the saline group had postoperative closure failure compared with 25% of patients in the hypochlorous acid group. Conclusions: Hypochlorous acid irrigation with ultrasound debridement reduced bacterial growth in chronic open wounds more efficiently than saline alone. Postoperative wound closure outcomes suggest a remarkable reduction in wound complications after wound debridement using hypochlorous acid irrigation with ultrasound versus saline alone.

  19. The Future of Carbon Dioxide for Polymer Processing in Tissue Engineering

    PubMed Central

    Bhamidipati, Manjari; Scurto, Aaron M.

    2013-01-01

    The use of CO2 for scaffold fabrication in tissue engineering was popularized in the mid-1990s as a tool for producing polymeric foam scaffolds, but had fallen out of favor to some extent, in part due to challenges with pore interconnectivity. Pore interconnectivity issues have since been resolved by numerous dedicated studies that have collectively outlined how to control the appropriate parameters to achieve a pore structure desirable for tissue regeneration. In addition to CO2 foaming, several groups have leveraged CO2 as a swelling agent to impregnate scaffolds with drugs and other bioactive additives, and for encapsulation of plasmids within scaffolds for gene delivery. Moreover, in contrast to CO2 foaming, which typically relies on supercritical CO2 at very high pressures, CO2 at much lower pressures has also been used to sinter polymeric microspheres together in the presence of cells to create cell-seeded scaffolds in a single step. CO2 has a number of advantages for polymer processing in tissue engineering, including its ease of use, low cost, and the opportunity to circumvent the use of organic solvents. Building on these advantages, and especially now with the tremendous precedent that has paved the way in defining operating parameters, and making the technology accessible for new groups to adapt, we invite and encourage our colleagues in the field to leverage CO2 as a new tool to enhance their own respective unique capabilities. PMID:23289736

  20. Preventing facial pressure ulcers in patients under non-invasive mechanical ventilation: a randomised control trial.

    PubMed

    Otero, D Peña; Domínguez, D Vazquez; Fernández, L Hernanz; Magariño, A Santano; González, V Jimenez; Klepzing, J V García; Montesinos, J V Beneit

    2017-03-02

    To comparatively assess the efficacy of four different therapeutic strategies to prevent the development of facial pressure ulcers (FPUs) related to the use of non-invasive mechanical ventilation (NIV) with oro-nasal masks in critically ill hospitalised patients. This randomised control trial was performed at the high dependency unit in the University General Hospital Gregorio Marañón in Madrid, Spain. Overall, 152 patients with acute respiratory failure were recruited. All patients were hospitalised and received NIV through oro-nasal masks. The Norton tool was used to evaluate the general risk of developing pressure ulcers (PUs). Subjects were divided into four groups, each of them receiving a different treatment. Tissue assessment and preventive care were performed by a member of the research team. The incidence of FPUs was significantly lower in the group receiving a solution of hyperoxygenated fatty acids (HOFA) when compared with each of the other therapeutic strategies: direct mask (p=0.055), adhesive thin dressing (p=0.03) and adhesive foam dressing (p<0.001). The application of HOFA on the facial skin in contact with the oro-nasal masks showed the highest efficacy in the prevention of NIV-related FPUs.

  1. Polyurethane-derived N-doped porous carbon with interconnected sheet-like structure as polysulfide reservoir for lithium-sulfur batteries

    NASA Astrophysics Data System (ADS)

    Xiao, Suo; Liu, Songhang; Zhang, Jianqiu; Wang, Yong

    2015-10-01

    Environmental pollution and energy deficiency are two key issues for the sustainable development of the modern society. Polyurethane foam is a typical commercial polymer with a large production quantity and its waste needs to be recycled. Lithium-sulfur battery is a promising energy-storage device with high energy density and low cost, but its demerits such as poor conductivity of the sulfur and severe capacity degradation due to the soluble lithium polysulfides are still a big challenge. This work reports a facile method to prepare nitrogen-doped porous carbon (NPC) from the polyurethane foam (PUF) waste and use it as a reservoir to impregnate sulfur for lithium-sulfur batteries. The obtained NPC has a unique interconnected sheet-like porous morphology with a large surface area of 1315 m2 g-1. The NPC-S composite delivers a large reversible capacity of 1118 mAh g-1 with good cycling performances and excellent high-rate capabilities. A large reversible capacity of 460 mAh g-1 can be retained at a large current of 5C (8.35 A g-1) after 100 cycles.

  2. Structural optimization of structured carbon-based energy-storing composite materials used in space vehicles.

    PubMed

    Yu, Jia; Yu, Zhichao; Tang, Chenlong

    2016-07-04

    The hot work environment of electronic components in the instrument cabin of spacecraft was researched, and a new thermal protection structure, namely graphite carbon foam, which is an impregnated phase-transition material, was adopted to implement the thermal control on the electronic components. We used the optimized parameters obtained from ANSYS to conduct 2D optimization, 3-D modeling and simulation, as well as the strength check. Finally, the optimization results were verified by experiments. The results showed that after optimization, the structured carbon-based energy-storing composite material could reduce the mass and realize the thermal control over electronic components. This phase-transition composite material still possesses excellent temperature control performance after its repeated melting and solidifying.

  3. Linseed hydrogel-mediated green synthesis of silver nanoparticles for antimicrobial and wound-dressing applications.

    PubMed

    Haseeb, Muhammad Tahir; Hussain, Muhammad Ajaz; Abbas, Khawar; Youssif, Bahaa Gm; Bashir, Sajid; Yuk, Soon Hong; Bukhari, Syed Nasir Abbas

    2017-01-01

    Polysaccharides are being extensively employed for the synthesis of silver nanoparticles (Ag NPs) having diverse morphology and applications. Herein, we present a novel and green synthesis of Ag NPs without using any physical reaction conditions. Linseed hydrogel (LSH) was used as a template to reduce Ag + to Ag 0 . AgNO 3 (10, 20, and 30 mmol) solutions were mixed with LSH suspension in deionized water and exposed to diffused sunlight. Reaction was monitored by noting the change in the color of reaction mixture up to 10 h. Ag NPs showed characteristic ultraviolet-visible (UV/Vis) absorptions from 410 to 437 nm in the case of sunlight and 397-410 nm in the case of temperature study. Transmission electron microscopy images revealed the formation of spherical Ag NPs in the range of 10-35 nm. Face-centered cubic array of Ag NPs was confirmed by characteristic diffraction peaks in powder X-ray diffraction spectrum. Ag NPs were stored in LSH thin films, and UV/Vis spectra recorded after 6 months indicated that Ag NPs retained their texture over the storage period. Significant antimicrobial activity was observed when microbial cultures (bacteria and fungi) were exposed to the synthesized Ag NPs. Wound-healing studies revealed that Ag NP-impregnated LSH thin films could have potential applications as an antimicrobial dressing in wound management procedures.

  4. Linseed hydrogel-mediated green synthesis of silver nanoparticles for antimicrobial and wound-dressing applications

    PubMed Central

    Haseeb, Muhammad Tahir; Hussain, Muhammad Ajaz; Abbas, Khawar; Youssif, Bahaa GM; Bashir, Sajid; Yuk, Soon Hong; Bukhari, Syed Nasir Abbas

    2017-01-01

    Polysaccharides are being extensively employed for the synthesis of silver nanoparticles (Ag NPs) having diverse morphology and applications. Herein, we present a novel and green synthesis of Ag NPs without using any physical reaction conditions. Linseed hydrogel (LSH) was used as a template to reduce Ag+ to Ag0. AgNO3 (10, 20, and 30 mmol) solutions were mixed with LSH suspension in deionized water and exposed to diffused sunlight. Reaction was monitored by noting the change in the color of reaction mixture up to 10 h. Ag NPs showed characteristic ultraviolet-visible (UV/Vis) absorptions from 410 to 437 nm in the case of sunlight and 397–410 nm in the case of temperature study. Transmission electron microscopy images revealed the formation of spherical Ag NPs in the range of 10–35 nm. Face-centered cubic array of Ag NPs was confirmed by characteristic diffraction peaks in powder X-ray diffraction spectrum. Ag NPs were stored in LSH thin films, and UV/Vis spectra recorded after 6 months indicated that Ag NPs retained their texture over the storage period. Significant antimicrobial activity was observed when microbial cultures (bacteria and fungi) were exposed to the synthesized Ag NPs. Wound-healing studies revealed that Ag NP–impregnated LSH thin films could have potential applications as an antimicrobial dressing in wound management procedures. PMID:28435262

  5. The efficacy and safety of natural honey on the healing of foot ulcers: a case series.

    PubMed

    Mohamed, Hashim; Salma, Mansour Abu; Al Lenjawi, Badriya; Abdi, Seham; Gouda, Zaghloul; Barakat, Nour; Elmahdi, Hisham; Abraham, Sisy; Hamza, Abdul Hakeem; Al Khozaei, Dhyiaa; Al Majid, Shawqia; Al Majid, Hanaa; Abdini, Johina; Al Jaber, Maryam; Al Masseh, Fareeda; Al Ali, Amal Abdulla

    2015-04-01

    This clinical observation investigated the efficacy, cost-effectiveness, and acceptability of natural honey on the healing of a variety of chronic foot ulcers at the primary care level. A total of 12 patients with foot ulcers utilizing natural honey as an effective alternative to more expensive, advanced wound products were followed. Cases were referred to Umgwailinah Primary Health Care Center, Doha, Qatar from different health centers and from Hamad General Hospital, Doha, Qatar. There were also self-referred cases. After rinsing the site with normal saline, natural honey was applied and the wound was covered by glycerin-impregnated gauze (Adaptic Non-Adhering Dressing, Systagenix, San Antonio, TX) to prevent the absorption of honey into the cotton gauze and away from the wound site. Patients were followed on a daily basis for an average of 4 weeks. All ulcers healed with no contractures or scars with a mean healing time of 3 weeks. There was a 75% reduction in the dressing budget of the health center and a high level of satisfaction among both health professionals and patients. Patients' pain levels were reduced significantly after using natural honey, as evidenced by the use of the Visual Analog Scale. The use of natural honey in the management of chronic foot ulcers proved to be efficacious, cost-effective, and acceptable by both clinicians and patients.

  6. Effectiveness of Pressure Ulcer Prevention Strategies for Adult Patients in Intensive Care Units: A Systematic Review.

    PubMed

    Tayyib, Nahla; Coyer, Fiona

    2016-12-01

    Pressure ulcers are associated with substantial health burden, but could be preventable. Hospital-acquired pressure ulcers (HAPUs) prevention has become a priority for all healthcare settings, as it is considered a sign of quality of care providing. Intensive care unit (ICU) patients are at higher risk for HAPUs development. Despite the availability of published prevention strategies, there is a little evidence about which strategies can be safely integrated into routine standard care and have an impact on HAPUs prevention. The aim was to synthesize the best available evidence regarding the effectiveness of single strategies designed to reduce the incidence and prevalence of HAPUs development in ICUs. The search strategy was designed to retrieve studies published in English across CINAHL, Medline, Cochrane Central Register of Controlled Trials, Embase, Scopus, and Mednar between 2000 and 2015. All adult ICU participants were aged 18 years or over. This review included randomized controlled trials, quasi-experimental and comparative studies. The studies that were selected for retrieval were assessed by two independent reviewers for methodological validity prior to inclusion in the review using standardized critical-appraisal instruments. The review included 25 studies, and the meta-analysis revealed a statistically significant effect of a silicon foam dressing strategy in reducing HAPUs incidence (effect size = 4.62; 95% CI: 0.05-0.29; p < .00001, effect size = 4.50; 95% CI: 0.05-0.31; p = .00001, respectively) in critically ill patients. Evidence of the effectiveness of nutrition, skin-care regimen, positioning and repositioning schedule, support surfaces, and the role of education in prevention of HAPUs development in the ICU was limited, which precludes strong conclusions. The review provides an evidence-based guide to future priorities for clinical practice. In particular, a silicone foam dressing has positive impact in reducing sacrum and heel HAPUs incidence in the ICU. © 2016 Sigma Theta Tau International.

  7. CO₂ sorption kinetics of scaled-up polyethylenimine-functionalized mesoporous silica sorbent.

    PubMed

    Al-Marri, M J; Khader, M M; Tawfik, M; Qi, G; Giannelis, E P

    2015-03-31

    Two CO2 solid sorbents based on polyethylenimine, PEI (M(n) ∼ 423 and 10K), impregnated into mesoporous silica (MPS) foam prepared in kilogram quantities via a scale-up process were synthesized and systematically characterized by a range of analytical and surface techniques. The mesoporous silica sorbent impregnated with lower molecular weight PEI, PEI-423/MPS, showed higher capacity toward CO2 sorption than the sorbent functionalized with the higher molecular weight PEI (PEI-10K/MPS). On the other hand, PEI-10K/MPS exhibited higher thermal stability than PEI-423/MPS. The kinetics of CO2 adsorption on both PEI/MPS fitted well with a double-exponential model. According to this model CO2 adsorption can be divided into two steps: the first is fast and is attributed to CO2 adsorption on the sorbent surface; the second is slower and can be related to the diffusion of CO2 within and between the mesoporous particles. In contrast, the desorption process obeyed first-order kinetics with activation energies of 64.3 and 140.7 kJ mol(-1) for PEI-423/MPS and PEI-10K/MPS, respectively. These studies suggest that the selection of amine is critical as it affects not only sorbent capacity and stability but also the energy penalty associated with sorbent regeneration.

  8. Properties of low-fat, low-cholesterol egg yolk prepared by supercritical CO2 extraction.

    PubMed

    Bringe, N A

    1997-01-01

    A dry egg yolk ingredient called Eggcellent has 74% less fat and 90% less cholesterol than liquid egg yolks, when reconstituted on an equal protein basis. The phospholipids and proteins are retained, enabling the ingredient to have the taste and texturizing properties of fresh egg yolk. Using the new yolk, it is possible to significantly improve the acceptability of low-fat, low-cholesterol bakery products, scrambled eggs and mayonnaise dressings without losing nutritional claims. The structures and functional properties of egg yolk components and the conditions required to optimize their benefits in foods are reviewed. The lipoproteins of low-fat, low-cholesterol yolk have valuable properties as flavorants, texturizers, foaming agents, emulsifiers, antioxidants, colorants, and nutraceuticals.

  9. Pilot study assessing the effectiveness of factory-treated, long-lasting permethrin-impregnated clothing for the prevention of tick bites during occupational tick exposure in highly infested military training areas, Germany.

    PubMed

    Faulde, Michael K; Rutenfranz, Martin; Keth, Alexander; Hepke, Jürgen; Rogge, Mareike; Görner, Andreas

    2015-02-01

    The protective effectiveness of factory-based permethrin-impregnated polymer-coated battle dress uniforms (PTBDUs) against tick bites was evaluated at four military training areas in southwestern and central Germany where tick bite incidence is known to be high. Data were analyzed by comparing tick bite incidence using non-permethrin-treated BDUs (NTBDUs) during 2009 versus PTBDUs during 2010 and 2011, the first two years after their formal introduction for in-country use in the German Bundeswehr. During 2009, 262 individual tick bites were reported at the four training sites, resulting in a tick bite incidence of 8.8 % per exposed person when wearing NTBDUs only. In 2010 and 2011, one tick bite case occurred under field conditions each year that PTBDUs were worn, corresponding to a protective effectiveness of 99.6 and 98.6 %. These data imply an annual tick bite incidence of 0.035 and 0.078 % per exposed person, respectively. Between 2010 and 2011, a 0.8 % decline in the protective effectiveness of PTBDUs was observed. Five tick bite incidents occurred while wearing non-impregnated parkas over correctly worn PTBDUs. Ixodes ricinus ticks were collected by standard tick drags from 2009 to 2011, with high mean annual densities ranging from 28.9 to 106.5 ticks per 100 m(2), while single drags revealed tick densities between zero and 381 ticks per 100 m(2). Overall, 4596 I. ricinus ticks (54 ♂, 82 ♀, 1776 nymphs, and 2684 larvae) were collected, of which 128 (2.8 %; mean annual range, 0-10.1 %) were Borrelia burgdorferi s.l. positive. The Borrelia genospecies distribution was as follows: 112 (87.5 %) Borrelia afzelii, 10 (7.8 %) B. burgdorferi s.s., and 6 (4.7 %) Borrelia garinii. Neither the tick density means from 2009 to 2011 nor associated B. burgdorferi s.l. prevalences differed significantly among the military locations investigated. The documented tick bite reductions clearly demonstrate the powerful protective effectiveness of properly worn PTBDUs against tick bites. Nevertheless, all apparel worn over PTBDUs should also be impregnated with permethrin in order to prevent tick infestation and subsequent bites.

  10. Honey Dressing Accelerates Split-Thickness Skin Graft Donor Site Healing.

    PubMed

    Subrahmanyam, M

    2015-12-01

    The management of the donor site after harvesting a skin graft is an important issue, as patients often report more discomfort at the donor site than at the recipient site. There is, however, a plethora of dressings available for the treatment and management of donor sites, yet, there is no widely accepted method established for these partial thickness wounds. Honey has been found to be useful in the treatment of burns and other wounds, split-thickness skin graft donor sites are like partial thickness burn wounds and honey's healing effect on burn wound can also be expected on these types of wounds. Therefore, this study was undertaken to evaluate the effect of honey on skin graft donor sites. From 2002 to 2004, 100 patients who have undergone skin grafting for various reasons formed the material of the randomized study divided into two groups of 50 each in honey-treated group and Vaseline gauze-treated group. Graft donor site area ranged from 30 to 48 cm(2), mean 32.6 cm(2). In the group treated with honey, 90 % of the patients had nil or only moderate pain, whereas in the group treated with Vaseline gauze,88 % had nil or mild pain (p > 0.001, not significant). There were no allergic reactions in any of the patients in either group. On opening of the dressing on the 7th day, epithelialization has occurred in 48 patients as compared to 39 in group 2, i.e., donor sites treated with Vaseline gauze (p < 0.05, statistically significant). By the 10th day, all the wounds healed in honey-treated group, whereas 76 % of wounds healed in Vaseline gauze-treated group (p < 0.05). At 1 month follow-up, the results were comparable in both groups, with regard to patient satisfaction. In conclusion, honey-impregnated gauze causes less pain and heals donor sites wounds faster with good cosmetic result.

  11. Porous bodies of hydroxyapatite produced by a combination of the gel-casting and polymer sponge methods

    PubMed Central

    González Ocampo, Jazmín I.; Escobar Sierra, Diana M.; Ossa Orozco, Claudia P.

    2015-01-01

    A combination of gel-casting and polymeric foam infiltration methods is used in this study to prepare porous bodies of hydroxyapatite (HA), to provide a better control over the microstructures of samples. These scaffolds were prepared by impregnating a body of porous polyurethane foam with slurry containing HA powder, and using a percentage of solids between 40% and 50% w/v, and three different types of monomers to provide a better performance. X-Ray Diffraction (XRD), and Fourier Transformed Infrared (FTIR) and Scanning Electron Microscopy (SEM) were employed to evaluate both the powder hydroxyapatite and the scaffolds obtained. In addition, porosity and interconnectivity measurements were taken in accordance with the international norm. Bioactivity was checked using immersion tests in Simulated Body Fluids (SBF). After the sintering process of the porous bodies, the XRD results showed peaks characteristic of a pure and crystalline HA (JCPDS 9-432) as a single phase. SEM images indicate open and interconnected pores inside the material, with pore sizes between 50 and 600 μm. Also, SEM images demonstrate the relatively good bioactivity of the HA scaffolds after immersion in SBF. All results for the porous HA bodies suggest that these materials have great potential for use in tissue engineering. PMID:26966570

  12. MBG-Modified β-TCP Scaffold Promotes Mesenchymal Stem Cells Adhesion and Osteogenic Differentiation via a FAK/MAPK Signaling Pathway.

    PubMed

    Liu, Yutong; Ma, Yifan; Zhang, Jing; Xie, Qing; Wang, Zi; Yu, Shuang; Yuan, Yuan; Liu, Changsheng

    2017-09-13

    The β-TCP scaffold has been widely used as a bone graft substitute, but the traditional PMMA molding method-induced undesirable mechanical strength and poor interconnectivity still have not been addressed until now. In this study, a MBG-based PU foam templating method was developed to fabricate β-TCP scaffolds with desirable microtopography. The MBG gel, as both binder and modifier, prepared by a modified sol-gel method with controlled viscosity is incorporated with β-TCP powder and thereafter is impregnated into PU foam. The resultant hybrid scaffolds exhibited interconnected macropores (200-500 μm) and distinctive micropores (0.2-1.5 μm), especially for the TCP/25MBG (with 25 wt % content MBG). As expected, the compression strength of β-TCP/MBG composite scaffolds was enhanced with increasing MBG content, and TCP/50MBG (with 50 wt % content MBG) exhibited almost 100-fold enhancement compared to the pure β-TCP. Intriguingly, the cell affinity and osteogenic capacity of rBMSCs were also dramatically improved the best on TCP/25MBG. Further investigation found that the subtle, grainy-like microtopography, not the chemical composition, of the TCP/25MBG favored the adsorption of Fn and expression of integrin α5β1 and further facilitated FA formation and the expression of p-FAK, following activation of the MAPK/ERK signaling pathway and ultimately upregulated expression of osteogenic genes. Further in vivo experiments confirmed the promoted osteogenesis of TCP/25MBG in vivo. The results suggest that such a novel MBG-based PU foam templating method offers new guidance to construct hierarchically porous scaffolds, and the prepared MBG-modified β-TCP scaffold will have great potential for future use in bone tissue regeneration.

  13. Retrospective clinical evaluation of gauze-based negative pressure wound therapy.

    PubMed

    Campbell, Penny E; Smith, Gary S; Smith, Jennifer M

    2008-06-01

    Negative pressure wound therapy (NPWT) is an established modality in the treatment of challenging wounds. However, most existing clinical evidence is derived from the use of open-cell polyurethane foam at -125 mmHg. Alternative negative pressure systems are becoming available, which use gauze at a pressure of -80 mmHg. This study describes clinical results from a retrospective non comparative analysis of 30 patients treated with Chariker-Jeter gauze-based negative pressure systems (V1STA, Versatile-1 and EZ-Care; Smith & Nephew, Inc.) in a long-term care setting. The mean age of the patients was 72 years. The wounds consisted of chronic (n = 11), surgical dehiscence (n = 11) and surgical incision (n = 8). Wound volume and area were recorded at commencement and at the cessation of therapy. Discontinuation of therapy was instigated upon closure through secondary intention or when size and exudate were sufficiently reduced that the wounds could be managed by conventional wound dressing (median 41 days). An overall median reduction in wound volume of 88.0% (P < 0.001) and a 68.0% reduction in area (P < 0.001) compared with baseline were observed over the course of NPWT. The overall rate of volume reduction (15.1% per week) compares favourably with published data from foam-based systems.

  14. Comparison on mechanical properties of single layered and bilayered chitosan-gelatin coated porous hydroxyapatite scaffold prepared through freeze drying method

    NASA Astrophysics Data System (ADS)

    Effendi, M. D.; Gustiono, D.; Lukmana; Ayu, D.; Kurniawati, F.

    2017-02-01

    Biopolymer coated porous hydroxyapatite (HA) scaffolds were prepared for tissue engineering trough freeze drying method and impregnation. in this study, to mimic the mineral and organic component of natural bone, synthetic hydroxapatite (HA) scaffolds coated by polymer were prepared. Highly porous Hap scaffolds, fabricated by synthetic HA impregnation method on polyurethane foam, were coated with polymer coating solution, consisting of chitosan, Gelatin, and bilayered chitosan-gelatin prepared by aging and impregnating technique. For the purpose of comparison, The bare scaffolds without polymer coating layer were investigated. The Bare scaffolds were highly porous and interconnected with a pore size of around 150 µm-714 µm, has porosity at around 67,7% -85,7%, and has mechanical strength at around 0.06 Mpa - 0.071 Mpa, which is suitable for osteoblast cell Proliferation. Chitosan coated porous HA scaffold and gelatin coated porous HA scaffold had mechanical strength at around 0.81-0.85 Mpa, and 1.32-1.34 Mpa, respectively, with weight ratio of biopolymer and Hap was around 18%-22%. To compare these results, the coating on the bare scaffold with gelatin and chitosan had been conducted. Based on the result of FTIR, it could be concluded that coating procedure applied on porous hydroxy apatite (HA) coated by gelatin, chitosan coated HA scaffold, and bilayered Gelatin-chitosan coated porous HA scaffold, confirming that for allsampleshad no significant chemical effect on the coating structure. The compressive strength of bilayered Gelatin-chitosan coated HA scaffold had middle values between the rest, at around 1,06-1.2 Mpa for the samples at the same weight ratio of biopolymer: HA (around 18% - 22%). These results also confirming that coating by gelatin on porous hydroxyapatite was highest compresive strength and can be applied to improve mechanical properties of porous hydroxyapatite bare scaffold

  15. Atypical cause of forearm skin ulceration in a leukaemic child: mucormycosis. A case report.

    PubMed

    Zirak, C; Brutus, J P; De Mey, A

    2005-01-01

    Primary cutaneous mucormycosis is an uncommon, deep and aggressive fungal infection occurring mainly in immunosuppressed or diabetic patients. Rapid diagnosis and therapy are necessary to prevent a fatal outcome. An eight-year-old leukaemic child presented with a dark necrotic ulcer on the volar-ulnar aspect of the left forehand. The lesion had developed over seven days, beginning as a vasculo-haemorrhagic erythematous plaque. There was no known history of trauma to the area, but skin necrosis from external compression caused by an intravenous line could not be completely ruled out. The lesion rapidly progressed to a 5 x 8 cm painful necrotic ulcer with an erythematous border. Treatment with ichthyol dressing and intra-venous antibiotherapy failed to improve the condition. Wide debridement was performed and specimens were sent for microbiology and pathology examinations. Microscopic examination demonstrated broad, irregularly walled, non-septate fungal hyphae that were consistent with Mucor. Amphotericin B was administrated intravenously (1 mg/kg/day) and hydrogel and hydrophile adhesive polyurethane foam dressings were applied. After 12 days, the soft tissue defect was covered with a split-thickness skin graft, harvested from the lateral aspect of the thigh. Diagnosis of this infection is based on complete histopathological and microbiological studies. Awareness, and a high index of suspicion are required because of the potential fulminant and fatal course.

  16. Integration of silver nanoparticle-impregnated polyelectrolyte multilayers into murine splinted cutaneous wound beds

    PubMed Central

    Guthrie, Kathleen M.; Agarwal, Ankit; Teixeira, Leandro B. C.; Dubielzig, Richard R.; Abbott, Nicholas L.; Murphy, Christopher J.; Singh, Harpreet; McAnulty, Jonathan F.; Schurr, Michael J.

    2013-01-01

    Silver is a commonly used topical antimicrobial. However, technologies to immobilize silver at the wound surface are lacking, while currently available silver-containing wound dressings release excess silver that can be cytotoxic and impair wound healing. We have shown that precise concentrations of silver at lower levels can be immobilized into a wound bed using a polyelectrolyte multilayer (PEM) attachment technology. These silver nanoparticle-impregnated PEMs are non-cytotoxic yet bactericidal in vitro, but their effect on wound healing in vivo was previously unknown. Objective The purpose of this study was to determine the effect on wound healing of integrating silver nanoparticle/PEMs into the wound bed. Methods A full-thickness, splinted, excisional murine wound healing model was employed in both phenotypically normal mice and spontaneously diabetic mice (healing impaired model). Results Gross image measurements showed an initial small lag in healing in the silver-treated wounds in diabetic mice, but no difference in time to complete wound closure in either normal or diabetic mice. Histological analysis showed modest differences between silver-treated and control groups on day 9, but no difference between groups at the time of wound closure. Conclusions We conclude that silver nanoparticle/PEMs can be safely integrated into the wound beds of both normal and diabetic mice without delaying wound closure, and with transient histological effects. The results of this study suggest the feasibility of this technology for use as a platform to effect nanoscale wound engineering approaches to microbial prophylaxis or to augment wound healing. PMID:23511285

  17. Application of Complex Fluids in Lignocellulose Processing

    NASA Astrophysics Data System (ADS)

    Carrillo Lugo, Carlos A.

    Complex fluids such as emulsions, microemulsions and foams, have been used for different applications due to the multiplicity of properties they possess. In the present work, such fluids are introduced as effective media for processing lignocellulosic biomass. A demonstration of the generic benefits of complex fluids is presented to enhance biomass impregnation, to facilitate pretreatment for fiber deconstruction and to make compatible cellulose fibrils with hydrophobic polymers during composite manufacture. An improved impregnation of woody biomass was accomplished by application of water-continuous microemulsions. Microemulsions with high water content, > 85%, were formulated and wood samples were impregnated by wicking and capillary flooding at atmospheric pressure and temperature. Formulations were designed to effectively impregnate different wood species during shorter times and to a larger extent compared to the single components of the microemulsions (water, oil or surfactant solutions). The viscosity of the microemulsions and their interactions with cell wall constituents in fibers were critical to define the extent of impregnation and solubilization. The relation between composition and formulation variables and the extent of microemulsion penetration in different woody substrates was studied. Formulation variables such as salinity content of the aqueous phase and type of surfactant were elucidated. Likewise, composition variables such as the water-to-oil ratio and surfactant concentration were investigated. These variables affected the characteristics of the microemulsion and determined their effectiveness in wood treatment. Also, the interactions between the surfactant and the substrate had an important contribution in defining microemulsion penetration in the capillary structure of wood. Microemulsions as an alternative pretreatment for the manufacture of cellulose nanofibrils (CNFs) was also studied. Microemulsions were applied to pretreat lignin-free and lignin-containing fibers obtained from various processes. Incorporation of active agents in the microemulsion facilitated fiber pretreatment before deconstruction via grinding and microfluidization. The energy consumed during the manufacture of cellulose nanofibrils was reduced by up to 55 and 32% in the case of lignin-containing and lignin-free fibers. Moreover, such pre-treatment did not affect negatively the mechanical properties of films prepared with the produced CNF. CNF was also used to enhance the stability of normal and multiple emulsions of the water-in-oil-in-water (W/O/W) type and to prevent their creaming. This was achieved by the marked increase in viscosity of the aqueous phase in the presence CNF. Finally, water-continuous emulsions were used to prepare nanocomposite fibers containing polystyrene and CNF. The morphology of composite fibers obtained after electrospinning of emulsions incorporating polystyrene and CNF was affected by parameters such the concentration of surfactant additives present in the microemulsion and the conductivity of the aqueous phase. Overall, emulsions and microemulsions are presented as a convenient platform to improve the compatibility between polymers of different hydrophilicity, to facilitate their processing and integration in composites.

  18. Integrating sol-gel with cold plasmas modified porous polycaprolactone membranes for the drug-release of silver-sulfadiazine and ketoprofen

    NASA Astrophysics Data System (ADS)

    Mangindaan, Dave; Chen, Chao-Ting; Wang, Meng-Jiy

    2012-12-01

    A controlled release system composed of surface modified porous polycaprolactone (PCL) membranes combined with a layer of tetraorthosilicate (TEOS)-chitosan sol-gel was reported in this study. PCL is a hydrophobic, semi-crystalline, and biodegradable polymer with a relatively slow degradation rate. The drugs chosen for release experiments were silver-sulfadiazine (AgSD) and ketoprofen which were impregnated in the TEOS-chitosan sol-gel. The surface modification was achieved by O2 plasma and the surfaces were characterized by water contact angle (WCA) measurements, atomic force microscope (AFM), scanning electron microscope and electron spectroscopy for chemical analysis (ESCA). The results showed that the release of AgSD on O2 plasma treated porous PCL membranes was prolonged when compared with the pristine sample. On the contrary, the release rate of ketoprofen revealed no significant difference on pristine and plasma treated PCL membranes. The prepared PCL membranes showed good biocompatibility for the wound dressing biomaterial applications.

  19. Unprecedented Silver Resistance in Clinically Isolated Enterobacteriaceae: Major Implications for Burn and Wound Management

    PubMed Central

    Norton, Rhy; Austin, Cindy; Mitchell, Amber; Zank, Sara; Durham, Paul

    2015-01-01

    Increased utilization of inorganic silver as an adjunctive to many medical devices has raised concerns of emergent silver resistance in clinical bacteria. Although the molecular basis for silver resistance has been previously characterized, to date, significant phenotypic expression of these genes in clinical settings is yet to be observed. Here, we identified the first strains of clinical bacteria expressing silver resistance at a level that could significantly impact wound care and the use of silver-based dressings. Screening of 859 clinical isolates confirmed 31 harbored at least 1 silver resistance gene. Despite the presence of these genes, MIC testing revealed most of the bacteria displayed little or no increase in resistance to ionic silver (200 to 300 μM Ag+). However, 2 isolates (Klebsiella pneumonia and Enterobacter cloacae) were capable of robust growth at exceedingly high silver concentrations, with MIC values reaching 5,500 μM Ag+. DNA sequencing of these two strains revealed the presence of genes homologous to known genetic determinants of heavy metal resistance. Darkening of the bacteria's pigment was observed after exposure to high silver concentrations. Scanning electron microscopy images showed the presence of silver nanoparticles embedded in the extracellular polymeric substance of both isolates. This finding suggested that the isolates may neutralize ionic silver via reduction to elemental silver. Antimicrobial testing revealed both organisms to be completely resistant to many commercially available silver-impregnated burn and wound dressings. Taken together, these findings provide the first evidence of clinical bacteria capable of expressing silver resistance at levels that could significantly impact wound management. PMID:26014954

  20. Development of Trace Contaminant Control Prototypes for the Primary Life Support System (PLSS)

    NASA Technical Reports Server (NTRS)

    Wojtowicz, Marek; Cosgrove, Joseph E.; Serio, Michael E.; Nalette, Tim; Guerrero, Sandra V.; Papale, William; Wilburn, Monique S.

    2017-01-01

    Results are presented on the development of Trace Contaminant Control (TCC) Prototypes for use in Extravehicular Activities (EVAs), and more specifically in the Primary Life Support System (PLSS). The current TC-control technology involves the use of a packed bed of acid-impregnated granular charcoal, which is non-regenerable, and the carbon-based sorbent under development in this project can be regenerated by exposure to vacuum at room temperature. Data on sorption and desorption of ammonia and formaldehyde, which are major TCs of concern, as well as pressure-drop calculations were used to design and test 1/6-scale and full-scale trace contaminant control system (TCCS) prototypes. Carbon sorbents were fabricated in both the granular and foam-supported forms. Sorbent performance was tested for ammonia sorption and vacuum regeneration in 1/6-scale, and pressure-drop characteristics were measured at flow rates relevant to the PLSS application.

  1. Ultra-high thermal effusivity materials for resonant ambient thermal energy harvesting.

    PubMed

    Cottrill, Anton L; Liu, Albert Tianxiang; Kunai, Yuichiro; Koman, Volodymyr B; Kaplan, Amir; Mahajan, Sayalee G; Liu, Pingwei; Toland, Aubrey R; Strano, Michael S

    2018-02-14

    Materials science has made progress in maximizing or minimizing the thermal conductivity of materials; however, the thermal effusivity-related to the product of conductivity and capacity-has received limited attention, despite its importance in the coupling of thermal energy to the environment. Herein, we design materials that maximize the thermal effusivity by impregnating copper and nickel foams with conformal, chemical-vapor-deposited graphene and octadecane as a phase change material. These materials are ideal for ambient energy harvesting in the form of what we call thermal resonators to generate persistent electrical power from thermal fluctuations over large ranges of frequencies. Theory and experiment demonstrate that the harvestable power for these devices is proportional to the thermal effusivity of the dominant thermal mass. To illustrate, we measure persistent energy harvesting from diurnal frequencies, extracting as high as 350 mV and 1.3 mW from approximately 10 °C diurnal temperature differences.

  2. Study to investigate design, fabrication and test of low cost concepts for large hybrid composite helicopter fuselage, phase 2

    NASA Technical Reports Server (NTRS)

    Adams, K. M.; Lucas, J. J.

    1977-01-01

    The development of a frame/stringer/skin fabrication technique for composite airframe construction was studied as a low cost approach to the manufacturer of larger helicopter airframe components. A center cabin aluminum airframe section of the Sikorsky CH-53D, was selected for evaluation as a composite structure. The design, as developed, is composed of a woven KEVLAR R-49/epoxy skin and graphite/epoxy frames and stringers. The single cure concept is made possible by the utilization of pre-molded foam cores, over which the graphite/epoxy pre-impregnated frame and stringer reinforcements are positioned. Bolted composite channel sections were selected as the optimum joint construction. The applicability of the single cure concept to larger realistic curved airframe sections, and the durability of the composite structure in a realistic spectrum fatigue environment, was described.

  3. Sterilization validation for medical compresses at IRASM multipurpose irradiation facility

    NASA Astrophysics Data System (ADS)

    Alexandru, Mioara; Ene, Mihaela

    2007-08-01

    In Romania, IRASM Radiation Processing Center is the unique supplier of radiation sterilization services—industrial scale (ISO 9001:2000 and ISO 13485:2003 certified). Its Laboratory of Microbiological Testing is the sole third party competent laboratory (GLPractice License, ISO 17025 certification in progress) for pharmaceutics and medical devices as well. We here refer to medical compresses as a distinct category of sterile products, made from different kind of hydrophilic materials (cotton, non-woven, polyurethane foam) with or without an impregnated ointment base (paraffin, plant extracts). These products are included in the class of medical devices, but for the sterilization validation, from microbiological point of view, there are important differences in testing method compared to the common medical devices (syringes, catheters, etc). In this paper, we present some results and practical solutions chosen to perform a sterilization validation, compliant with ISO 11137: 2006.

  4. Use of negative pressure wound therapy in the treatment of neonatal and pediatric wounds: a retrospective examination of clinical outcomes.

    PubMed

    Baharestani, Mona Mylene

    2007-06-01

    The clinical effectiveness of negative pressure wound therapy for the management of acute and chronic wounds is well documented in the adult population but information regarding its use in the pediatric population is limited. A retrospective, descriptive study was conducted to examine the clinical outcomes of using negative pressure wound therapy in the treatment of pediatric wounds. The medical records of 24 consecutive pediatric patients receiving negative pressure wound therapy were reviewed. Demographic data, wound etiology, time to closure, closure method, duration of negative pressure wound therapy, complications, dressing change frequency, dressing type used, and pressure settings were analyzed. All categorical variables in the dataset were summarized using frequency (count and percentages) and all continuous variables were summarized using median (minimum, maximum). The 24 pediatric patients (mean age 8.5 years [range 14 days to 18 years old]) had 24 wounds - 12 (50%) were infected at baseline. Sixteen patients had hypoalbuminemia and six had exposed hardware and bone in their wounds. Twenty-two wounds reached full closure in a median time of 10 days (range 2 to 45) following negative pressure wound therapy and flap closure (11), split-thickness skin graft (three), secondary (four), and primary (four) closure. Pressures used in this population ranged from 50 to 125 mm Hg and most wounds were covered with reticulated polyurethane foam. One patient developed a fistula during the course of negative pressure wound therapy. When coupled with appropriate systemic antibiotics, surgical debridement, and medical and nutritional optimization, in this population negative pressure wound therapy resulted in rapid granulation tissue and 92% successful wound closure. Future neonatal and pediatric negative pressure wound therapy usage registries and prospective studies are needed to provide a strong evidence base from which treatment decisions can be made in the management of these challenging cases, especially pertaining to the safety and efficacy of pressure settings, dressings, and interposing contact layer selection.

  5. Effect of Negative Pressure Wound Therapy vs Standard Wound Management on 12-Month Disability Among Adults With Severe Open Fracture of the Lower Limb: The WOLLF Randomized Clinical Trial.

    PubMed

    Costa, Matthew L; Achten, Juul; Bruce, Julie; Tutton, Elizabeth; Petrou, Stavros; Lamb, Sarah E; Parsons, Nick R

    2018-06-12

    Open fractures of the lower limb occur when a broken bone penetrates the skin. There can be major complications from these fractures, which can be life-changing. To assess the disability, rate of deep infection, and quality of life in patients with severe open fracture of the lower limb treated with negative pressure wound therapy (NPWT) vs standard wound management after the first surgical debridement of the wound. Multicenter randomized trial performed in the UK Major Trauma Network, recruiting 460 patients aged 16 years or older with a severe open fracture of the lower limb from July 2012 through December 2015. Final outcome data were collected through November 2016. Exclusions were presentation more than 72 hours after injury and inability to complete questionnaires. NPWT (n = 226) in which an open-cell solid foam or gauze was placed over the surface of the wound and connected to a suction pump, creating a partial vacuum over the dressing, vs standard dressings not involving application of negative pressure (n = 234). Disability Rating Index score (range, 0 [no disability] to 100 [completely disabled]) at 12 months was the primary outcome measure, with a minimal clinically important difference of 8 points. Secondary outcomes were complications including deep infection and quality of life (score ranged from 1 [best possible] to -0.59 [worst possible]; minimal clinically important difference, 0.08) collected at 3, 6, 9, and 12 months. Among 460 patients who were randomized (mean age, 45.3 years; 74% men), 88% (374/427) of available study participants completed the trial. There were no statistically significant differences in the patients' Disability Rating Index score at 12 months (mean score, 45.5 in the NPWT group vs 42.4 in the standard dressing group; mean difference, -3.9 [95% CI, -8.9 to 1.2]; P = .13), in the number of deep surgical site infections (16 [7.1%] in the NPWT group vs 19 [8.1%] in the standard dressing group; difference, 1.0% [95% CI, -4.2% to 6.3%]; P = .64), or in quality of life between groups (difference in EuroQol 5-dimensions questionnaire, 0.02 [95% CI, -0.05 to 0.08]; Short Form-12 Physical Component Score, 0.5 [95% CI, -3.1 to 4.1] and Mental Health Component Score, -0.4 [95% CI, -2.2 to 1.4]). Among patients with severe open fracture of the lower limb, use of NPWT compared with standard wound dressing did not improve self-rated disability at 12 months. The findings do not support this treatment for severe open fractures. isrctn.org Identifier: ISRCTN33756652.

  6. A pilot study of the use of kaolin-impregnated gauze (Combat Gauze) for packing high-grade hepatic injuries in a hypothermic coagulopathic swine model.

    PubMed

    Sena, Matthew J; Douglas, Geoffrey; Gerlach, Travis; Grayson, J Kevin; Pichakron, Kullada O; Zierold, Dustin

    2013-08-01

    Severe hepatic injuries may be highly lethal, and perihepatic packing remains the mainstay of treatment. This is not always successful, particularly in the setting of hypothermia and coagulopathy. Kaolin-impregnated Combat Gauze (CG) is an effective hemostatic dressing used primarily to treat external wounds. The objective of this study was to determine the ability of CG to control severe hemorrhage in hypothermic, coagulopathic swine with a high-grade hepatic injury. Anesthetized animals underwent splenectomy and were cooled to 32°C while undergoing a 60% exchange transfusion with Hextend. A grade V liver injury was created in the left middle hepatic lobe. Animals were allowed to freely bleed for 30 s and then randomized to treatment with CG or plain gauze laparotomy pads (PG) applied to the injury site. Animals were then resuscitated with warmed Hextend. There was no difference between groups in preinjury hemodynamic or laboratory values. Animals packed with CG had less blood loss when compared with standard packing (CG = 25 mL/kg versus PG = 58 mL/kg, P = 0.05). There was a trend towards lower hetastarch resuscitation requirements in the CG group (CG = 7 mL/kg versus PG = 44 mL/kg, P = 0.06) but no statistically significant difference in mortality (CG = 13% versus PG = 50%, P = 0.11). Histology of the injury sites revealed more adherent clot in the CG group, but no inflammation, tissue necrosis, or residual material. In pigs with severe hepatic injury, Combat Gauze reduced blood loss and resuscitation requirements when compared with plain laparotomy pads. Combat Gauze may be safe and effective for use on severe liver injuries. Published by Elsevier Inc.

  7. In situ solvothermal growth of metal-organic framework-5 supported on porous copper foam for noninvasive sampling of plant volatile sulfides.

    PubMed

    Hu, Yuling; Lian, Haixian; Zhou, Langjun; Li, Gongke

    2015-01-06

    The present study reported on an in situ solvothermal growth method for immobilization of metal-organic framework MOF-5 on porous copper foam support for enrichment of plant volatile sulfides. The porous copper support impregnated with mother liquor of MOF-5 anchors the nucleation and growth of MOF crystallites at its surface, and its architecture of the three-dimensional channel enables accommodation of the MOF-5 crystallite seed. A continuous and well-intergrown MOF-5 layer, evidenced from scanning electron microscope imaging and X-ray diffraction, was successfully immobilized on the porous metal bar with good adhesion and high stability. Results show that the resultant MOF-5 coating was thermally stable up to 420 °C and robust enough for replicate extraction for at least 200 times. The MOF-5 bar was then applied to the headspace sorptive extraction of the volatile organic sulfur compounds in Chinese chive and garlic sprout in combination with thermal desorption-gas chromatography/mass spectrometry. It showed high extraction sensitivity and good selectivity to these plant volatile sulfides owing to the extraordinary porosity of the metal-organic framework as well as the interaction between the S-donor sites and the surface cations at the crystal edges. Several primary sulfur volatiles containing allyl methyl sulfide, dimethyl disulfide, diallyl sulfide, methyl allyl disulfide, and diallyl disulfide were quantified. Their limits of detection were found to be in the range of 0.2-1.7 μg/L. The organic sulfides were detected in the range of 6.0-23.8 μg/g with recoveries of 76.6-100.2% in Chinese chive and 11.4-54.6 μg/g with recoveries of 77.1-99.8% in garlic sprout. The results indicate the immobilization of MOF-5 on copper foam provides an efficient enrichment formats for noninvasive sampling of plant volatiles.

  8. Prevention of Tracheostomy-Related Hospital-Acquired Pressure Ulcers.

    PubMed

    O'Toole, Thomas R; Jacobs, Natalie; Hondorp, Brian; Crawford, Laura; Boudreau, Lisa R; Jeffe, Jill; Stein, Brian; LoSavio, Phillip

    2017-04-01

    Objective To determine if standardization of perioperative tracheostomy care procedures decreased the incidence of hospital-acquired tracheostomy-related pressure ulcers. Methods All patients at least 18 years old who underwent placement of a tracheostomy tube in the operating room from July 1, 2014, through June 30, 2015, were cared for postoperatively through an institutionally adopted quality improvement protocol. This included 4 elements: (1) placement of a hydrocolloid dressing underneath the tracheostomy flange in the postoperative period, (2) removal of plate sutures within 7 days of the tracheostomy procedure, (3) placement of a polyurethane foam dressing after suture removal, and (4) neutral positioning of the head. One year after the bundle was initiated, a retrospective analysis was performed to compare the percentage of tracheostomy patients who developed pressure ulcers versus the preintervention period. Results The incidence of tracheostomy-related pressure ulcers decreased from 20 of 183 tracheostomies (10.93%) prior to use of the standardized protocol to 2 of 155 tracheostomies (1.29%). Chi-square analysis showed a significant difference between the groups, with a P value of .0003. Discussion Adoption of this care bundle at our institution resulted in a significant reduction in the incidence of hospital-acquired tracheostomy-related pressure ulcers. The impact of any single intervention within our protocol was not assessed and could be an area of further investigation. Implications for Practice Adoption of a standardized posttracheostomy care bundle at the institution level may result in the improved care of patients with tracheostomies and specifically may reduce the incidence of pressure ulcers.

  9. Combing a novel device and negative pressure wound therapy for managing the wound around a colostomy in the open abdomen: A case report.

    PubMed

    Sun, Xiaofang; Wu, Shaohan; Xie, Ting; Zhang, Jianping

    2017-12-01

    An open abdomen complicated with small-bowel fistulae becomes a complex wound for local infection, systemic sepsis and persistent soiling irritation by intestinal content. While controlling the fistulae drainage, protecting surrounding skin, healing the wound maybe a challenge. In this paper we described a 68-year-old female was admitted to emergency surgery in general surgery department with severe abdomen pain. Resection part of the injured small bowel, drainage of the intra-abdominal abscess, and fashioning of a colostomy were performed. She failed to improve and ultimately there was tenderness and lot of pus under the skin around the fistulae. The wound started as a 3-cm lesion and progressed to a 6 ×13  (78 cm) around the stoma. In our case we present a novel device for managing colostomy wound combination with negative pressure wound therapy. This tube allows for an effective drainage of small-bowel secretion and a safe build-up of granulation tissue. Also it could be a barrier between the bowel suction point and foam. Management of open abdomen wound involves initial dressing changes, antibiotic use and cutaneous closure. When compared with traditional dressing changes, the NPWT offers several advantages including increased granulation tissue formation, reduction in bacterial colonization, decreased of bowel edema and wound size, and enhanced neovascularization. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  10. [Application of Care Bundles to Reduce Medical-Device-Related Pressure Injury (MDRPI) Incidence in a Coronary Care Unit].

    PubMed

    Wang, Shu-Ling; Chuang, Pao-Yu; Su, Wan-Chuan

    2018-06-01

    Pressure injuries increase the cost of medical care and prolong hospitalization. The incidence of pressure injury at the target coronary care unit (CCU) from January to August 2016 was 1.1%, which was significantly higher than the 0.4% defined in the 2015 Taiwan Clinical Performance Indicators (TCPI) system. Medical device related pressure injury (MDRPI) accounted for 73.1% of the pressure injuries (incidence: 0.8%). The main causes of the high incidence of MDRPI were: (1) inadequate decompression dressing and restraint equipment, (2) incomplete implementation of prevention interventions in the CCU, (3) inadequate knowledge of MDRPI prevention among nurses, (4) deficient standards for preventing MDRPI, (5) ineffective MDRPI-related education, and (6) insufficient auditing frequencies. To reduce the incidence of MDRPI in the target CCU to 0.4% or less. Promote a seed-teacher system and a care bundle that "increased skin tolerance, decompression, medical dressing, change, and removal" using education, the adoption of PE-foam binding gloves, and regular audits. The incidence of MDRPI was reduced from 0.8% to 0.3% between October 2016 and April 2017 and further reduced to 0.1% during the maintenance phase between May and July 2017. The results indicate that the improvement program effectively reduced the incidence of MDRPI and thus increased the quality of nursing care. Therefore, the use of a care bundles should be promoted in intensive care units.

  11. Synthesis and wound healing of alternating block polyurethanes based on poly(lactic acid) (PLA) and poly(ethylene glycol) (PEG).

    PubMed

    Li, Linjing; Liu, Xiangyu; Niu, Yuqing; Ye, Jianfu; Huang, Shuiwen; Liu, Chao; Xu, Kaitian

    2017-07-01

    Alternating block polyurethanes (abbreviated as PULA-alt-PEG) and random block polyurethanes (abbreviated as PULA-ran-PEG) based on biodegradable poly(lactic acid) (PLA) and poly(ethylene glycol) (PEG) were prepared. Results showed that alternating block polyurethane gives higher crystal degree, higher mechanical properties, more patterned and rougher surface than the random counterpart, due to the regular and controlled structure. Water absorptions of the polyurethanes were in the range of 620 to 780%. Cytocompatibility of the amphiphilic block polyurethanes (PU) (water static angle 41.4°-61.8°) was assessed by CCK-8 assay using human embryonic kidney (HEK293) cells. Wound healing evaluation of the PU foam scaffolds was carried out by full-thickness SD rat model experiment, with medical gauze as control. It was found that the skin of rat in PU groups was fully covered with new epithelium without any significant adverse reactions and PU dressings give much rapid and better healing than medical gauze. Histological examination revealed that PU dressings suppress the infiltration of inflammatory cells and accelerate fibroblast proliferation. It was also demonstrated that PULA-alt-PEG exhibits obvious better healing effect than PULA-ran-PEG does. This study has demonstrated that without further modification, plain alternating block polyurethane scaffold would help wound recovery efficiently. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1200-1209, 2017. © 2016 Wiley Periodicals, Inc.

  12. In vitro investigations of a novel wound dressing concept based on biodegradable polyurethane

    NASA Astrophysics Data System (ADS)

    Rottmar, Markus; Richter, Michael; Mäder, Xenia; Grieder, Kathrin; Nuss, Katja; Karol, Agnieszka; von Rechenberg, Brigitte; Zimmermann, Erika; Buser, Stephan; Dobmann, Andreas; Blume, Jessica; Bruinink, Arie

    2015-06-01

    Non-healing and partially healing wounds are an important problem not only for the patient but also for the public health care system. Current treatment solutions are far from optimal regarding the chosen material properties as well as price and source. Biodegradable polyurethane (PUR) scaffolds have shown great promise for in vivo tissue engineering approaches, but accomplishment of the goal of scaffold degradation and new tissue formation developing in parallel has not been observed so far in skin wound repair. In this study, the mechanical properties and degradation behavior as well as the biocompatibility of a low-cost synthetic, pathogen-free, biocompatible and biodegradable extracellular matrix mimicking a PUR scaffold was evaluated in vitro. The novel PUR scaffolds were found to meet all the requirements for optimal scaffolds and wound dressings. These three-dimensional scaffolds are soft, highly porous, and form-stable and can be easily cut into any shape desired. All the material formulations investigated were found to be nontoxic. One formulation was able to be defined that supported both good fibroblast cell attachment and cell proliferation to colonize the scaffold. Tunable biodegradation velocity of the materials could be observed, and the results additionally indicated that calcium plays a crucial role in PUR degradation. Our results suggest that the PUR materials evaluated in this study are promising candidates for next-generation wound treatment systems and support the concept of using foam scaffolds for improved in vivo tissue engineering and regeneration.

  13. Porous media for catalytic renewable energy conversion

    NASA Astrophysics Data System (ADS)

    Hotz, Nico

    2012-05-01

    A novel flow-based method is presented to place catalytic nanoparticles into a reactor by sol-gelation of a porous ceramic consisting of copper-based nanoparticles, silica sand, ceramic binder, and a gelation agent. This method allows for the placement of a liquid precursor containing the catalyst into the final reactor geometry without the need of impregnating or coating of a substrate with the catalytic material. The so generated foam-like porous ceramic shows properties highly appropriate for use as catalytic reactor material, e.g., reasonable pressure drop due to its porosity, high thermal and catalytic stability, and excellent catalytic behavior. The catalytic activity of micro-reactors containing this foam-like ceramic is tested in terms of their ability to convert alcoholic biofuel (e.g. methanol) to a hydrogen-rich gas mixture with low concentrations of carbon monoxide (up to 75% hydrogen content and less than 0.2% CO, for the case of methanol). This gas mixture is subsequently used in a low-temperature fuel cell, converting the hydrogen directly to electricity. A low concentration of CO is crucial to avoid poisoning of the fuel cell catalyst. Since conventional Polymer Electrolyte Membrane (PEM) fuel cells require CO concentrations far below 100 ppm and since most methods to reduce the mole fraction of CO (such as Preferential Oxidation or PROX) have CO conversions of up to 99%, the alcohol fuel reformer has to achieve initial CO mole fractions significantly below 1%. The catalyst and the porous ceramic reactor of the present study can successfully fulfill this requirement.

  14. Defluoridation technology for drinking water and tea by green synthesized Fe3O4/Al2O3 nanoparticles coated polyurethane foams for rural communities.

    PubMed

    Kumari, Sonu; Khan, Suphiya

    2017-08-14

    Fluoride (F) contaminated ground water poses a serious public health concern to rural population with unaffordable purification technologies. Therefore, development of a cost-effective, portable, environment and user-friendly defluoridation technique is imperative. In the present study, we report on the development of a green and cost-effective method that utilizes Fe 3 O 4 and Al 2 O 3 nanoparticles (NPs) that were synthesized using jojoba defatted meal. These NPs were impregnated on to polyurethane foam (PUF) and made into tea infusion bags. The Al 2 O 3 NPs-PUF displayed a higher water defluoridation capacity of 43.47 mg g -1 of F as compared to 34.48 mg g -1 of F with Fe 3 O 4 NPs-PUF. The synthesized Al 2 O 3 -PUF infusion bags removed the F that was under the permissible limit of 1.5 mg L -1 . The sorption experiments were conducted to verify the effect of different parameters such as pH, contact time, size of PUF and initial F concentration. The different properties of adsorbent were characterized using a combination of FESEM, EDX, XRD and FTIR techniques, respectively. The calculated total cost per NPs-PUF pouch developed is as low as US $0.05, which makes the technology most suitable for rural communities. This paper will be beneficial for researchers working toward further improvement in water purification technologies.

  15. Evaluation of model parameters for growth, tannic acid utilization and tannase production in Bacillus gottheilii M2S2 using polyurethane foam blocks as support.

    PubMed

    Selvaraj, Subbalaxmi; Vytla, Ramachandra Murty

    2017-10-01

    Production of tannase from B. gottheilii M2S2 was studied under solid-state fermentation with an optimized medium consisting of polyurethane foam matrix of dimension 40 × 40 × 5 mm, impregnated with a liquid medium comprising (w/v): 4% tannic acid; 2% NH 4 NO 3 ; 0.1% KH 2 PO 4 ; 0.2% MgSO 4 ; 0.1% NaCl and 0.05% CaCl 2 ·2H 2 O in distilled water, having a pH of 4.7. Maximum tannase production of 56.87 U/L was obtained after 32 h of fermentation at 32 °C in static condition. This study deals with the evaluation of unstructured kinetic models to understand the behavior of biomass, tannase production and tannic acid degradation, with the fermentation time. The growth rate of B. gottheilii M2S2 was 0.0703 h -1 at 32 h of fermentation. Product ( Y x/s ) and biomass yield ( Y p/s ) coefficients were estimated as 1.77 U/g of tannic acid and 0.276 g of biomass/g of tannic acid. All the kinetic constants µ , α , β , m and n were evaluated using MATLAB 2015Rb program. The experimental and model-generated data showed a good correlation, which indicated that these models will describe tannase production and fermentation process.

  16. Co-Adsorption of Ammonia and Formaldehyde on Regenerable Carbon Sorbents for the Primary Life Support System (PLSS)

    NASA Technical Reports Server (NTRS)

    Wojtowicz, Marek A.; Cosgrove, Joseph E.; Serio, Michael A.; Wilburn, Monique S.

    2016-01-01

    Results are presented on the development of a reversible carbon sorbent for trace-contaminant (TC) removal for use in Extravehicular Activities (EVAs), and more specifically in the Primary Life Support System (PLSS). The current TC-control technology involves the use of a packed bed of acid-impregnated granular charcoal, which is deemed non-regenerable, while the carbon-based sorbent under development in this project can be regenerated by exposure to vacuum at room temperature. Data on concurrent sorption and desorption of ammonia and formaldehyde, which are major TCs of concern, are presented in this paper. A carbon sorbent was fabricated by dry impregnation of a reticulated carbon-foam support with polyvinylidene chloride, followed by carbonization and thermal oxidation in air. Sorbent performance was tested for ammonia and formaldehyde sorption and vacuum regeneration, with and without water present in the gas stream. It was found that humidity in the gas phase enhanced ammonia-sorption capacity by a factor larger than two. Co-adsorption of ammonia and formaldehyde in the presence of water resulted in strong formaldehyde sorption (to the point that it was difficult to saturate the sorbent on the time scales used in this study). In the absence of humidity, adsorption of formaldehyde on the carbon surface was found to impair ammonia sorption in subsequent runs; in the presence of water, however, both ammonia and formaldehyde could be efficiently removed from the gas phase by the sorbent. The efficiency of vacuum regeneration could be enhanced by gentle heating to temperatures below 60 deg.

  17. Prevention of catheter-related blood stream infection.

    PubMed

    Byrnes, Matthew C; Coopersmith, Craig M

    2007-08-01

    Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.

  18. Pin site care for preventing infections associated with external bone fixators and pins.

    PubMed

    Lethaby, Anne; Temple, Jenny; Santy-Tomlinson, Julie

    2013-12-03

    Metal pins are used to apply skeletal traction or external fixation devices in the management of orthopaedic fractures. These percutaneous pins protrude through the skin, and the way in which they are treated after insertion may affect the incidence of pin site infection. This review set out to summarise the evidence of pin site care on infection rates. To assess the effect on infection rates of different methods of cleansing and dressing orthopaedic percutaneous pin sites. In September 2013, for this third update, we searched the Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. We evaluated all randomised controlled trials (RCTs) that compared the effect on infection and other complication rates of different methods of cleansing or dressing orthopaedic percutaneous pin sites. Two review authors independently assessed the citations retrieved by the search strategies for reports of relevant RCTs, then independently selected trials that satisfied the inclusion criteria, extracted data and undertook quality assessment. A total of eleven trials (572 participants) were eligible for inclusion in the review but not all participants contributed data to each comparison. Three trials compared a cleansing regimen (saline, alcohol, hydrogen peroxide or antibacterial soap) with no cleansing (application of a dry dressing), three trials compared alternative sterile cleansing solutions (saline, alcohol, peroxide, povidone iodine), three trials compared methods of cleansing (one trial compared identical pin site care performed daily or weekly and the two others compared sterile with non sterile techniques), one trial compared daily pin site care with no care and six trials compared different dressings (using different solutions/ointments and dry and impregnated gauze or sponges). One small blinded study of 38 patients found that the risk of pin site infection was significantly reduced with polyhexamethylene biguanide (PHMB) gauze when compared to plain gauze (RR 0.23, 95% CI 0.12 to 0.44) (infection rate of 1% in the PHMB group and 4.5% in the control group) but this study was at high risk of bias as the unit of analysis was observations rather than patients. There were no other statistically significant differences between groups in any of the other trials. The available trial evidence was not extensive, was very heterogeneous and generally of poor quality, so there was insufficient evidence to be able to identify a strategy of pin site care that minimises infection rates. Adequately-powered randomised trials are required to examine the effects of different pin care regimens, and co-interventions - such as antibiotic use - and other extraneous factors must be controlled in the study designs.

  19. High Accuracy Investigation of Microwave Absorption in Polymer Electrical Components on Motherboard of Computers

    NASA Astrophysics Data System (ADS)

    Dašić, P.; Hutanu, C.; Jevremović, V.; Dobra, R.; Risteiu, M.; Ileana, I.

    2017-06-01

    Electronic operating at high frequencies can have problems with emission of high frequency noise. Once put inside an enclosure, the energy will add in phase at certain frequencies to cause resonances which will hinder the performance of the device. These absorbers are based upon open celled foam impregnated with a carbon coating. It is quite possible that in the near future, microprocessors would be to work on a frequency located in 5 to 10 GHz. In these circumstances it is useful to know how and how much of the electromagnetic field emitted by a microprocessor, it is absorbed by the circuit elements in the immediate vicinity of the microprocessor. The aim of this contribution is to demonstrate throughout high-level experimental analysis how the main electric parameters of polymer materials, which build the printed circuits and the one of electric capacitors and resistors, depend on the frequencies on which they work from the microwave range.

  20. 21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydrogel wound dressing and burn dressing. 878... Hydrogel wound dressing and burn dressing. (a) Identification. A hydrogel wound dressing is a sterile or non-sterile device intended to cover a wound, to absorb wound exudate, to control bleeding or fluid...

  1. 21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydrogel wound dressing and burn dressing. 878... Hydrogel wound dressing and burn dressing. (a) Identification. A hydrogel wound dressing is a sterile or non-sterile device intended to cover a wound, to absorb wound exudate, to control bleeding or fluid...

  2. Comparison of two silver dressings for wound management in pediatric burns.

    PubMed

    Jester, Ingo; Bohn, Ingo; Hannmann, Thorsten; Waag, Karl-Ludwig; Loff, Steffan

    2008-11-01

    Purpose. Silver wound dressings are widely used in the treatment of burns. Dressings differ in material characteristics, various antimicrobial activities, and ease of use. The purpose of this study was to evaluate both dressing performance and amount of pain during the dressing changes of 2 silver dressings Urgotul SSD® (Laboratoires Urgo, Chenove, France), and Contreet Ag® (Coloplast, Minneapolis, MN) in children. A retrospective cohort study was performed with 2 groups of 20 burns treated with Urgotul SSD and Contreet Ag until the wounds were healed or grafted. Seventy dressing changes in the Contreet Ag group and 67 dressing changes in the Urgotul group were evaluated. Every dressing change was assessed regarding the dressing performance (exudate, adherence, bleeding, and dressing application/removal), and pain. Pain was "absent or slight" in 61 (92%) dressing changes with Urgotul SSD, and in 60 (85%) of the dressing changes with Contreet Ag. Dressing application in the Urgotul group was more often "very easy" (n = 33; 49%) or "easy" (n = 32; 48%) than in the Contreet Ag group, "very easy" (n = 25; 35%), and "easy" (n = 42; 60%). Contreet Ag had a greater ability to absorb exudate ("very good" n = 60; 85%, and "good" n = 11; 15%) than Urgotul SSD ("very good" n = 34; 51%, and "good" n = 13; 19%). Urgotul SSD and Contreet Ag are comparable regarding pain during dressing change. The dressings differ in their ability to absorb exudate and ease of application. Both dressings provided nearly painless wound management, and therefore were highly accepted by the nurses and especially the children being treated.

  3. Choosing a Wound Dressing Based on Common Wound Characteristics

    PubMed Central

    Dabiri, Ganary; Damstetter, Elizabeth; Phillips, Tania

    2016-01-01

    Significance: Chronic wounds are a major healthcare burden.The practitioner should have an appropriate understanding of both the etiology of the wound as well as the optimal type of dressings to use. Fundamental wound characteristics may be used to guide the practitioner's choice of dressings. The identification of optimal dressings to use for a particular wound type is an important element in facilitating wound healing. Recent Advances: Researchers have sought to design wound dressings that aim to optimize each stage in the healing process. In addition, dressings have been designed to target and kill infection-causing bacteria, with the incorporation of antimicrobial agents. Critical Issues: Chronic wounds are frequently dynamic in presentation, and the numerous wound dressings available make dressing selection challenging for the practitioner. Choosing the correct dressing decreases time to healing, provides cost-effective care, and improves patient quality of life. Future Directions: Research into the mechanisms of wound healing has enhanced our ability to heal chronic wounds at a faster rate through the use of moisture-retentive dressings. Newer dressings are incorporating the use of nanotechnology by incorporating miniature electrical sensors into the dressing. These dressings are engineered to detect changes in a wound environment and alert the patient or practitioner by altering the color of the dressing or sending a message to a smartphone. Additional investigations are underway that incorporate biologic material such as stem cells into dressings. PMID:26858913

  4. A clinical review of infected wound treatment with Vacuum Assisted Closure (V.A.C.) therapy: experience and case series.

    PubMed

    Gabriel, Allen; Shores, Jaimie; Bernstein, Brent; de Leon, Jean; Kamepalli, Ravi; Wolvos, Tom; Baharestani, Mona M; Gupta, Subhas

    2009-10-01

    Over the last decade Vacuum Assisted Closure((R)) (KCI Licensing, Inc., San Antonio, TX) has been established as an effective wound care modality for managing complex acute and chronic wounds. The therapy has been widely adopted by many institutions to treat a variety of wound types. Increasingly, the therapy is being used to manage infected and critically colonized, difficult-to-treat wounds. This growing interest coupled with practitioner uncertainty in using the therapy in the presence of infection prompted the convening of an interprofessional expert advisory panel to determine appropriate use of the different modalities of negative pressure wound therapy (NPWT) as delivered by V.A.C.((R)) Therapy and V.A.C. Instill((R)) with either GranuFoam() or GranuFoam Silver() Dressings. The panel reviewed infected wound treatment methods within the context of evidence-based medicine coupled with experiential insight using V.A.C.((R)) Therapy Systems to manage a variety of infected wounds. The primary objectives of the panel were 1) to exchange state-of-practice evidence, 2) to review and evaluate the strength of existing data, and 3) to develop practice recommendations based on published evidence and clinical experience regarding use of the V.A.C.((R)) Therapy Systems in infected wounds. These recommendations are meant to identify which infected wounds will benefit from the most appropriate V.A.C.((R)) Therapy System modality and provide an infected wound treatment algorithm that may lead to a better understanding of optimal treatment strategies.

  5. Amino Acid-Based Material for the Complementary Therapy of Decubitus Ulcers.

    PubMed

    Nogueira, Frederico; Gouveia, Isabel C

    2017-04-28

    Chronic wounds, pressure sores, lesions, and infections of microbial origin in bedridden, paralyzed, or malnutrition patients remain the object of study of many researchers. A variety of factors behind the development of these disorders are related to the patient's immune system, making it unable to respond effectively to the treatment of the wound. These factors can be properly controlled, giving particular importance to the ethiology and stage of the wound, as well as the time periods corresponding to the replacement of the dressings. The present research reports a novel foam/soft material, L -Cys-g-PCL, with an application for decubitus/pressure ulcers, especially for wounds with a difficult healing process due to infections and constant oxidation of the soft tissues. During this work, the interactions between S. aureus and L -Cys-g-PCL foam were studied under conditions that simulate decubitus ulcers; namely, pH and exudate. The effects of duration of grafting (1 or 8 h) and pH (7.0 and 8.9) on wettability, surface energy, swelling, and porosity were also evaluated. Results showed an effective microbicidal activity exhibiting an inhibition ratio of 99.73% against S. aureu s. This new L -Cys-g-PCL soft material showed saftey to contact skin, ability to be shaped to fill in sunken holes (craters) - pressure ulcers stage III - and to act as a smart material responsive to pH, which can be tailored to develop better swelling properties at alkaline pH where exudates are normally higher, so as to address exudate self-cleaning and prevention of desiccation..

  6. Comparison of collagen matrix treatment impregnated with platelet rich plasma vs bone marrow.

    PubMed

    Minamimura, Ai; Ichioka, Shigeru; Sano, Hitomi; Sekiya, Naomi

    2014-02-01

    This study has reported the efficacy of an autologous bone marrow-impregnated collagen matrix experimentally and clinically. Then, it reflected that platelet rich plasma (PRP) was as good a source of growth factors as bone marrow and available in a less invasive procedure. This study aimed to compare the efficacy of a PRP-impregnated collagen matrix with that of a bone marrow-impregnated collagen matrix by quantifying wound size and capillary density using genetically diabetic db/db mice. Bone marrow cells were obtained from femurs of ddy mice. Then, a small amount of collagen matrix was immersed in bone marrow suspension. This is called a bone marrow-impregnated collagen matrix. PRP was obtained from healthy human blood and a small amount of collagen matrix was immersed in PRP. This is called a PRP-impregnated collagen matrix. A bone marrow-impregnated collagen matrix and PRP-impregnated collagen matrix were applied to excisional skin wounds on a genetically healing-impaired mouse (n = 6) and wounds were evaluated 6 days after the procedure. Wounds were divided into two groups: PRP (n = 6), in which a PRP-impregnated collagen matrix was applied; and bone marrow (n = 6), in which collagen immersed in a bone marrow suspension was applied. There was no significant difference between the PRP and bone-marrow groups in the rate of vascular density increase or wound size decrease. The present study suggested that the PRP-impregnated collagen matrix promotes repair processes at least as strongly as the bone marrow-impregnated collagen matrix. Given lower invasiveness, the PRP-impregnated collagen matrix would have advantages in clinical use.

  7. Comparison of EDTA and SDS as potential surface impregnation agents for lead adsorption by activated carbon

    NASA Astrophysics Data System (ADS)

    Chen, Wei-fang; Pan, Ling; Chen, Li-fang; Yu, Zhe; Wang, Qiong; Yan, Chang-cheng

    2014-08-01

    Ethylene diamine tetraacetic acid (EDTA) and sodium dodecyl sulfate (SDS) were employed to impregnate activated carbons for the purpose of lead removal. The mechanisms of surface impregnation and lead adsorption method of chemical regeneration were investigated. Results showed that the highest impregnation of EDTA and SDS on activated carbon was 0.33 and 0.96 mmol/g, respectively. Adsorption capacities for lead of EDTA and SDS impregnated activated carbons reached 0.29 and 0.24 mmol/g. Rapid small scale column tests of adsorption and regeneration were conducted. Lead adsorption was greatly enhanced by EDTA impregnation. In addition, EDTA impregnated adsorbent was able to be successful regenerated by HNO3 and thus reused.

  8. Evaluation of a non-adherent, povidone-iodine dressing in a case series of chronic wounds.

    PubMed

    Campbell, N; Campbell, D

    2013-08-01

    Here we report a product evaluation for a non-adherent, povidone-iodine (PVP-I) dressing, determining the clinical need for the product, performing a literature review, clinical evaluation and cost-analysis, and developing a recommendation. This evaluation included 20 patients who experienced dressing pain with the previous antimicrobial dressing. Two patients discontinued the evaluation and four ulcers were non-healing; the remaining wounds closed with the PVP-I dressing. Patients indicated a preference for the PVP-I dressing, primarily due to lack of dressing pain. The PVP-I dressing was also the most cost-efficient.

  9. Apple snack enriched with L-arginine using vacuum impregnation/ohmic heating technology.

    PubMed

    Moreno, Jorge; Echeverria, Julian; Silva, Andrea; Escudero, Andrea; Petzold, Guillermo; Mella, Karla; Escudero, Carlos

    2017-07-01

    Modern life has created a high demand for functional food, and in this context, emerging technologies such as vacuum impregnation and ohmic heating have been applied to generate functional foods. The aim of this research was to enrich the content of the semi-essential amino acid L-arginine in apple cubes using vacuum impregnation, conventional heating, and ohmic heating. Additionally, combined vacuum impregnation/conventional heating and vacuum impregnation/ohmic heating treatments were evaluated. The above treatments were applied at 30, 40 and 50  ℃ and combined with air-drying at 40 ℃ in order to obtain an apple snack rich in L-arginine. Both the impregnation kinetics of L-arginine and sample color were evaluated. The impregnated samples created using vacuum impregnation/ohmic heating at 50 ℃ presented a high content of L-arginine, an effect attributed primarily to electropermeabilization. Overall, vacuum impregnation/ohmic heating treatment at 50 ℃, followed by drying at 40 ℃, was the best process for obtaining an apple snack rich in L-arginine.

  10. A prospective randomised study comparing the jubilee dressing method to a standard adhesive dressing for total hip and knee replacements.

    PubMed

    Burke, Neil G; Green, Connor; McHugh, Gavin; McGolderick, Niall; Kilcoyne, Carol; Kenny, Patrick

    2012-08-01

    It is important to reduce potential wound complications in total hip and total knee arthroplasty procedures. The purpose of this study was to compare the jubilee dressing method to a standard adhesive dressing. 124 patients (62 total hip replacements and 62 total knee replacements) were randomly selected to have either a standard adhesive dressing or jubilee method dressing. The number of dressing changes, incidence of blistering, leakage, appearance of inflammation, infection rate and the average stay in hospital was recorded for each patient. The jubilee dressing significantly reduced the rate of blistering, leakage and number of dressing changes when compare to a traditional adhesive dressing (p < 0.05). The rate of inflammation and average length of stay in hospital was not significantly different between the two groups. The authors recommend the use of this dressing for total hip and total knee arthroplasty procedures due to the associated lower complication rate. Copyright © 2012 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  11. Adhesive retention dressings are more comfortable than alginate dressings on split-skin-graft donor sites.

    PubMed

    Hormbrey, E; Pandya, A; Giele, H

    2003-07-01

    Painful split-skin-graft donor sites remain a common problem for patients. We undertook a prospective randomised trial to examine the comparative comfort and ease of care of two different donor-site dressings. One dressing is the alginate Kaltostat, the standard plastic-surgical dressing in the UK and abroad, and the other is the adhesive retention tape Mefix, a novel use of a readily available dressing. We randomised 50 patients requiring split-skin grafts to receive either alginate (Kaltostat) or retention (Mefix) donor-site dressings. Dressings were assessed by interview and questionnaire at 24, 72 h and 2 weeks, and by wound review at 2 weeks. Retention dressings were found to be more comfortable, required less nursing intervention and allowed patients easier mobility with a greater range of daily activities, especially washing, without compromising wound healing. We recommend adhesive retention dressings as cost-effective comfortable dressings, which readily conform to any donor site.

  12. Managers, Teachers, Students, and Parents' Opinions Concerning Changes on Dress Code Practices as an Educational Policy

    ERIC Educational Resources Information Center

    Birel, Firat Kiyas

    2016-01-01

    Problem Statement: Dressing for school has been intensely disputed and has led to periodic changes in dress codes since the foundation of the Turkish republic. Practitioners have tried to put some new practices related to school dress codes into practice for redressing former dress code issues involving mandatory dress standards for both students…

  13. Australasian survey of split skin graft donor site dressings.

    PubMed

    Lyall, P W; Sinclair, S W

    2000-02-01

    There is an ever increasing array of products available for wound dressings. The aim of the present study was to establish which dressings should be used as standard controls for future studies; what factors are regarded as most important in assessing a dressing; what the level of satisfaction is with the available products; what the strengths and weaknesses of the commonly used dressings are; and what dressings would be preferred if cost were no issue. A postal survey was sent to every plastic and reconstructive surgeon registered in Australasia (n = 217). A total of 53% responded. The most commonly used dressing type overall is the calcium alginates, despite the fact that they were not the highest performing dressings. This is also the most commonly used in Australia. In contrast scarlet red is still used most commonly in New Zealand. The level of satisfaction with the most commonly used dressing varied very little. The factor regarded most important was patient comfort level. A profile of the commonly used dressing was constructed. Calcium alginates and or scarlet red should be used as the control for new product comparisons. Most of the respondents were satisfied with their preferred dressing and were not interested in trying alternative dressings.

  14. A pilot trial of bordered polyurethane dressings, tissue adhesive and sutureless devices compared with standard polyurethane dressings for securing short-term arterial catheters.

    PubMed

    Edwards, Melannie; Rickard, Claire M; Rapchuk, Ivan; Corley, Amanda; Marsh, Nicole; Spooner, Amy J; Mihala, Gabor; Fraser, John F

    2014-09-01

    To improve arterial catheter (AC) securement and reduce AC failure; to assess feasibility of a large randomised controlled trial. A four-arm, parallel, randomised, controlled, non-blinded pilot trial with 195 intensive care patients taking part, in a tertiary referral hospital in Brisbane, Australia from May to November 2012. Standard polyurethane (SPU) dressing (controls); bordered polyurethane (BPU) + SPU dressing; tissue adhesive (TA) + SPU dressing; and sutureless securement device (SSD) + SPU dressing (no sutures used). AC failure, ie, complete dislodgement, occlusion (monitor failure, inability to infuse or fluid leaking), pain or infection (local or blood). Median AC dwell time was 26.2 hours and was comparable between groups. AC failure occurred in 26/195 patients (13%). AC failure was significantly worse with SPU dressings (10/47 [21%]) than with BPU + SPU dressings (2/ 43 [5%]; P = 0.03), but not significantly different to TA + SPU (6/56 [11%]; P = 0.18) or SSD + SPU (8/49 [16%]; P = 0.61). The dressing applied at AC insertion lasted until AC removal in 68% of controls; 56% of BPU + SPU dressings; 73% of TA + SPU dressings; and 80% of SSD + SPU dressings (all P > 0.05). There were no infections or serious adverse events. Patient and staff satisfaction with all products was high. Median costs (labour and materials) for securement per patient were significantly higher in all groups compared with the control group (SPU, $3.48 [IQR, $3.48-$9.79]; BPU + SPU, $5.07 [IQR, $5.07-$12.99]; SSD + SPU, $10.90 [IQR, $10.90-$10.90]; TA + SPU, $17.70 [IQR, $17.70-$38.36]; all P < 0.01). AC failure occurred significantly less often with BPU + SPU dressings than with SPU dressings. TA + SPU and SSD + SPU dressings should be further investigated and compared with BPU + SPU dressings as controls. The novel approach of TA + SPU dressings appeared safe and feasible.

  15. Negative pressure wound therapy in pediatric surgery: How and when to use.

    PubMed

    de Jesus, Lisieux Eyer; Martins, Alana Bandeira; Oliveira, Pablo Baptista; Gomes, Fernanda; Leve, Thais; Dekermacher, Samuel

    2018-04-01

    Negative pressure wound therapy (NPWT) has been widely adopted to treat laparostomy, abdominal compartment syndrome (ACS) and complicated wounds associated with tissue loss. The method presents specific aspects, advantages and indications in Pediatrics. Our aim is to review the evidence available about NPWT in children. Active search for papers about NPWT in Pediatric patients. Papers referring to orthopedic problems, wound complications after Cardiac Surgery or burns were excluded. The method shows good results to treat ACS, complicated wounds and abdominal wall malformations in neonates, including prematures. Periwound skin protection, monitoring of fluid losses and fine tuning of negative pressure levels according to age are necessary. Less pain, quicker recovery, less frequent dressing changes, possible recovery of exposed surgical hardware, granulation and shrinkage of the wound are advantages of the method over other kinds of dressing. NPWT is contraindicated over blood vessels and exposed nerves. Debridement is needed before usage over necrotic areas. Enteric fistulae are not contraindications. Complications are rare, mainly foam retention and dermatitis/skin maceration. The possibility of fistulae being caused by NPWT remains debatable. NPWT is widely used in Pediatrics, including neonates and premature, but the evidence available about the method is scarce and low quality. Complications are uncommon and mostly manageable. A possible causal relationship between NPWY and enteric fistula remains unclear. Adult devices and parameters have been adapted to children's use. Extra care is needed to protect the delicate tissues of Pediatric patients. Comparative research to define differential costs, indications and advantages of the method, specific indications and limits of NWTP in Pediatrics is needed. Review. IV. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Dressing remedies: a concept for improving access to and use of dressings in nursing homes.

    PubMed

    Clarkson, A

    2007-01-01

    Delays in accessing dressings prescribed by general practitioners can result in the inappropriate use of dressings on more than one resident in nursing homes. The dressing remedies concept was developed to overcomes this problem.

  17. Experimental Analysis of Critical Current and Alternating Current Losses of High-Temperature Superconductor Tape with Resin and Gallium-Indium-Tin

    PubMed Central

    Sun, Yajie; Zhang, Huiming; Meng, Yuanzhu

    2018-01-01

    This paper experimentally analyzes the critical current degradation and AC (alternating current) losses of second-generation (2G) high-temperature superconductor (HTS) tape during the impregnation process. Two impregnation materials were utilized: Gallium-Indium-Tin (GaInSn), and an epoxy resin, Araldite. The critical current of the impregnation materials was measured after different thermal cycles and compared with the tape with no impregnation process. The experimental results show that the critical current of Yttrium Barium Copper Oxide (YBCO) short samples varies between differently impregnated materials. The resin, Araldite, degraded the critical current; however, the GaInSn showed no degradation. Two degradation patterns with Araldite were identified due to the impregnation process, and the corresponding causes were analyzed. We further measured the AC losses of tapes impregnated with liquid metal at different frequencies, up to 600 Hz. Based on the experimental results, GaInSn liquid metal should be the most suitable impregnation material in terms of critical current degradation. PMID:29642490

  18. Experimental Analysis of Critical Current and Alternating Current Losses of High-Temperature Superconductor Tape with Resin and Gallium-Indium-Tin.

    PubMed

    Yu, Dongmin; Sun, Yajie; Zhang, Huiming; Meng, Yuanzhu; Liu, Huanan

    2018-04-08

    This paper experimentally analyzes the critical current degradation and AC (alternating current) losses of second-generation (2G) high-temperature superconductor (HTS) tape during the impregnation process. Two impregnation materials were utilized: Gallium-Indium-Tin (GaInSn), and an epoxy resin, Araldite. The critical current of the impregnation materials was measured after different thermal cycles and compared with the tape with no impregnation process. The experimental results show that the critical current of Yttrium Barium Copper Oxide (YBCO) short samples varies between differently impregnated materials. The resin, Araldite, degraded the critical current; however, the GaInSn showed no degradation. Two degradation patterns with Araldite were identified due to the impregnation process, and the corresponding causes were analyzed. We further measured the AC losses of tapes impregnated with liquid metal at different frequencies, up to 600 Hz. Based on the experimental results, GaInSn liquid metal should be the most suitable impregnation material in terms of critical current degradation.

  19. Mercury adsorption of modified mulberry twig chars in a simulated flue gas.

    PubMed

    Shu, Tong; Lu, Ping; He, Nan

    2013-05-01

    Mulberry twig chars were prepared by pyrolysis, steam activation and impregnation with H2O2, ZnCl2 and NaCl. Textural characteristics and surface functional groups were performed using nitrogen adsorption and FTIR, respectively. Mercury adsorption of different modified MT chars was investigated in a quartz fixed-bed absorber. The results indicated that steam activation and H2O2-impregnation can improve pore structure significantly and H2O2-impregnation and chloride-impregnation promote surface functional groups. However, chloride-impregnation has adverse effect on pore structure. Mercury adsorption capacities of impregnated MT chars with 10% or 30% H2O2 are 2.02 and 1.77 times of steam activated MT char, respectively. Mercury adsorption capacity of ZnCl2-impregnated MT char increase with increasing ZnCl2 content and is better than that of NaCl-impregnated MT char at the same chloride content. The modified MT char (MT873-A-Z5) prepared by steam activation following impregnation with 5% ZnCl2 exhibits a higher mercury adsorption capacity (29.55 μg g(-1)) than any other MT chars. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Exit-Site Dressing and Infection in Peritoneal Dialysis: A Randomized Controlled Pilot Trial.

    PubMed

    Mushahar, Lily; Mei, Lim Wei; Yusuf, Wan Shaariah; Sivathasan, Sudhaharan; Kamaruddin, Norilah; Idzham, Nor Juliana Mohd

    2016-01-01

    ♦ Peritoneal dialysis (PD)-related infection is a common cause of catheter loss and the main reason for PD drop-out. Exit-site infection (ESI) is a pathway to developing tunnel infection and peritonitis, hence rigorous exit-site care has always been emphasized in PD therapy. The aim of this study was to evaluate the effect of exit-site dressing vs non-dressing on the rate of PD-related infection. ♦ A prospective randomized controlled study was conducted in prevalent PD patients at the Hospital Tuanku Jaafar Seremban, Negeri Sembilan, Malaysia, from April 2011 until April 2013. All patients were required to perform daily washing of the exit site with antibacterial soap during a shower. In the dressing group (n = 54), patients were required to clean their exit site using povidone-iodine after drying, followed by topical mupirocin antibiotic application to the exit site. The exit site was then covered with a sterile gauze dressing and the catheter immobilized with tape. In the non-dressing group (n = 54), patients were not required to do any further dressing after drying. They were only required to apply mupirocin cream to the exit site and then left the exit site uncovered. The catheter was immobilized with tape. The primary outcome was ESI. The secondary outcomes were evidence of tunnel infection or peritonitis. ♦ A total of 97 patients completed the study. There were a total of 12 ESI episodes: 4 episodes in 4 patients in the dressing group vs 8 episodes in 4 patients in the non-dressing group. This corresponds to 1 episode per 241.3 patient-months vs 1 episode per 111.1 patient-months in the dressing and non-dressing groups respectively. Median time to first ESI episode was shorter in the non-dressing than in the dressing group, but not significant (p = 0.25). The incidence of gram-positive ESI in both groups was similar. There were no gram-negative ESI in the non-dressing group compared with 2 in the dressing group. The peritonitis rate was 1 per 37.1 patient-month in the dressing group and 1 per 44.4 patient-months in the non-dressing group. Median time to first peritonitis episode was significantly shorter in the dressing group compared to non-dressing (p = 0.03). There was no impact of dressing disruptions in the occurrence of major PD catheter-related infection. ♦ Use of a non-dressing technique with only prophylactic topical mupirocin cream application is effective in preventing PD-related infection. The non-dressing technique is more cost-effective and convenient for PD patients, with fewer disposables. Copyright © 2016 International Society for Peritoneal Dialysis.

  1. Effect of autohydrolysis on the wettability, absorbility and further alkali impregnation of poplar wood chips.

    PubMed

    Xu, Ningpan; Liu, Wei; Hou, Qingxi; Wang, Peiyun; Yao, Zhirong

    2016-09-01

    Autohydrolysis with different severity factors was performed on poplar wood chips prior to pulping, and the wettability, absorbility and the following impregnation of NaOH solution for the poplar wood chips were then investigated. The results showed that after autohydrolysis pretreatment the porosity, shrinkage and fiber saturation point (FSP) of the poplar wood chips were increased, while the surface contact angle decreased as the severity factor was increased. The autohydrolyzed chips absorbed more NaOH in impregnation that resulted in a low NaOH concentration in the bulk impregnation liquor (i.e., the impregnation liquor outside wood chips), while the concentration in the entrapped liquor (i.e., the impregnation liquor inside wood chips) was increased. Autohydrolysis substantially improved the effectiveness of alkali impregnation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Exposure to 4,4'-methylenediphenyl diisocyanate (MDI) during moulding of rigid polyurethane foam: determination of airborne MDI and urinary 4,4'-methylenedianiline (MDA).

    PubMed

    Kääriä, K; Hirvonen, A; Norppa, H; Piirilä, P; Vainio, H; Rosenberg, C

    2001-04-01

    Occupational exposure to 4,4'-methylenediphenyl diisocyanate (MDI) was measured during moulding of rigid polyurethane foam. The aim of the study was to find out whether an MDI-derived urinary amine metabolite could be detected in the urine of workers exposed to apparently low levels of MDI. Airborne MDI was sampled on 1-(2-methoxyphenyl)-piperazine (2MP)-impregnated glass fibre filters and determined by high-performance liquid chromatography (HPLC) using ultraviolet (UV) and electrochemical (EC) detection. The limit of detection of MDI was 3 ng ml-1 for a 20 microliters injection. The precision of sample preparation, expressed as relative standard deviation (RSD), was 1.3% with UV detection and 2.1% with EC detection at a concentration of 70 ng MDI ml-1 (n = 6). The 2MP-MDI derivative was stable at +4 degrees C up to eight weeks. The accuracy of the method was validated in an international quality control programme. Workers (n = 57) from three different factories participated in the study. Urinary 4,4'-methylenedianiline (MDA) metabolite was determined after acid hydrolysis as heptafluorobutyric anhydride derivatives by gas chromatography-mass spectrometry using chemical ionisation and monitoring negative ions. The limit of detection in urine was 0.2 nmol l-1. The precision of six analyses for a urine sample spiked to a concentration of 1 nmol l-1 was 29% (RSD). The MDI concentrations were below the limit of detection in most (64%) of the air samples collected in the worker's breathing zone. Still, detectable amounts of MDA were found in 97% of the urine samples. Monitoring of urinary MDA appears to be an appropriate method of assessing MDI exposure in work environments with low or undetectable MDI concentrations in the workplace air.

  3. Rapid vacuum sintering: A novel technique for fabricating fluorapatite ceramic scaffolds for bone tissue engineering.

    PubMed

    Denry, Isabelle; Goudouri, Ourania-Menti; Harless, Jeffrey; Holloway, Julie A

    2018-01-01

    Macroporous bioceramic scaffolds are often fabricated via the foam replica technique, based on polymeric foam impregnation with a glass slurry, followed by slow heat treatment to allow for drying, polymeric burnout, and sintering of the glass particles. As a consequence, the process is time consuming and complicated by concurrent crystallization of the glass, often leading to incomplete sintering. Our goal was to investigate the effect of heating rate on sintering behavior, architecture, and mechanical properties of fluorapatite-based glass and glass-ceramic scaffolds. Glass scaffolds were prepared and sintered by rapid vacuum sintering (RVS) at 785°C under vacuum at a fast heating rate (55°C/min.) or without vacuum at a slow heating rate (2°C/min.). Two additional groups were further crystallized at 775°C/1 h. XRD confirmed the presence of fluorapatite for crystallized scaffolds. All groups presented interconnected porosity with a pore size in the 500 μm range. Scaffolds produced by RVS exhibited an excellent degree of sintering while scaffolds produced by slow sintering were incompletely sintered. The mean compressive strength was significantly higher for the RVS groups (1.52 ± 0.55 and 1.72 ± 0.61 MPa) compared to the slow-sintered groups (0.54 ± 0.30 and 0.45 ± 0.26 MPa). Meanwhile, the total production time was reduced by more than 12 h by using the RVS technique. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 291-299, 2018. © 2017 Wiley Periodicals, Inc.

  4. Adhesive, elastomeric gel impregnating composition

    DOEpatents

    Shaw, David Glenn; Pollard, John Randolph; Brooks, Robert Aubrey

    2002-01-01

    An improved capacitor roll with alternating film and foil layers is impregnated with an adhesive, elastomeric gel composition. The gel composition is a blend of a plasticizer, a polyol, a maleic anhydride that reacts with the polyol to form a polyester, and a catalyst for the reaction. The impregnant composition is introduced to the film and foil layers while still in a liquid form and then pressure is applied to aid with impregnation. The impregnant composition is cured to form the adhesive, elastomeric gel. Pressure is maintained during curing.

  5. Dress Nicer = Know More? Young Children’s Knowledge Attribution and Selective Learning Based on How Others Dress

    PubMed Central

    McDonald, Kyla P.; Ma, Lili

    2015-01-01

    This research explored whether children judge the knowledge state of others and selectively learn novel information from them based on how they dress. The results indicated that 4- and 6-year-olds identified a formally dressed individual as more knowledgeable about new things in general than a casually dressed one (Study 1). Moreover, children displayed an overall preference to seek help from a formally dressed individual rather than a casually dressed one when learning about novel objects and animals (Study 2). These findings are discussed in relation to the halo effect, and may have important implications for child educators regarding how instructor dress might influence young students’ knowledge attribution and learning preferences. PMID:26636980

  6. Are biopolymers potential deodourising agents in wound management?

    PubMed

    Lee, G; Anand, S C; Rajendran, S

    2009-07-01

    To investigate the odour-adsorbing properties of biopolymers, with a view to using the findings to develop a novel dressing with odour-adsorbing properties. The odour-adsorbing properties of a selection of biopolymers (aloe vera, tea tree oil, neem oil and manuka honey) and three commercially available dressings containing activated charcoal cloth (ACC) were quantitatively assessed using laboratory test equipment. An aloe vera-containing composite dressing, designed and developed by the authors, was also compared with the ACC dressings. Aloe vera was the most adsorbent of the biopolymers and a 40% dilution had comparable values to those of the ACC dressings. Furthermore, values for the novel composite dressing were similar to those of the ACC dressings. The novel composite dressing may be a potential alternative to ACC dressings, and has the added advantages of having antimicrobial properties as well as the ability to promote a moist wound environment. However, more research is needed.

  7. Dressing disrupted: negotiating care through the materiality of dress in the context of dementia.

    PubMed

    Buse, Christina; Twigg, Julia

    2018-02-01

    This paper explores how the materiality of dress mediates and shapes practices of care in the context of dementia. Earlier research called for an approach to conceptualising care that recognised the role played by everyday artefacts. We extend this to a consideration of dress and dressing the body in relation to people with dementia that involves the direct manipulation of material objects, as well as the materiality of bodies. The paper draws on an ESRC funded study Dementia and Dress, which examined experiences of dress for people with dementia, families and care-workers using ethnographic and qualitative methods. Our analysis explores the process of dressing the body, the physicality of guiding and manipulating bodies into clothing, dealing with fabrics and bodies which 'act back' and are resistant to the process of dressing. We consider how the materiality of clothing can constrain or enable practices of care, exploring tensions between garments that support ease of dressing and those that sustain identity. Examining negotiations around dress also reveals tensions between competing 'logics' of care (Mol ). © 2018 The Authors. Sociology of Health & Illness published by John Wiley & Sons Ltd on behalf of Foundation for SHIL.

  8. Effect of periodontal dressings on human gingiva fibroblasts in vitro

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eber, R.M.; Shuler, C.F.; Buchanan, W.

    1989-08-01

    In vitro cytotoxicity studies of periodontal dressings have not generally produced a result consistent with in vivo observations. These prior in vitro studies have not used human intraoral cell lines. We tested the effects of two eugenol containing and two non-eugenol periodontal dressings on cultured human gingival fibroblasts (HGF) (ATCC No. 1292). Replicate HGF cultures grown in microtiter plates were exposed to stock, 1:4 and 1:16 dilutions of extracts made from each of the four periodontal dressings. The HGF cultures were pulse labelled with tritiated thymidine (3HTdR) after 24, 48, and 72 hours. Incorporations of the labelled thymidine were measuredmore » using liquid scintillation counting and expressed as counts per minute. The results showed that undiluted extracts from all four periodontal dressings totally inhibited 3HTdR uptake (P less than 0.05). The 1:4 dilution of eugenol dressings inhibited 3HTdR uptake significantly more than non-eugenol dressings (P less than 0.05). Interestingly, at 72 hours the 1:16 dilution of the non-eugenol dressings caused significantly increased 3HTdR uptake which was not observed with the eugenol dressings. The present results suggest that the use of a human fibroblastic cell line for testing the effects of periodontal dressings may provide information about the relative biological effects of these dressings. Using this cell line, we have found that eugenol dressings inhibit fibroblast proliferation to a greater extent than non-eugenol dressings.« less

  9. Impregnation of Fenofibrate on mesoporous silica using supercritical carbon dioxide.

    PubMed

    Bouledjouidja, Abir; Masmoudi, Yasmine; Van Speybroeck, Michiel; Schueller, Laurent; Badens, Elisabeth

    2016-02-29

    Low oral bioavailability can be circumvented by the formulation of the poorly water soluble drug in ordered mesoporous silica (OMS-L-7). Fenofibrate is an orally administered, poorly water-soluble active pharmaceutical ingredient (API), used clinically to lower lipid levels. Fenofibrate was loaded into silica using two methods: incipient wetness and supercritical impregnation. This study investigates the impact of loading and the impact of varying supercritical carbon dioxide (scCO2) processing conditions. The objective is to enhance Fenofibrate loading into silica while reducing degree of the drug crystallinity, so as to increase the drug's dissolution rate and its bioavailability. The comparison of both impregnation processes was made in terms of impregnation yields and duration as well as physical characterization of the drug. While incipient wetness method led to a Fenofibrate loading up to 300 mgdrug/gsilica in 48 h of impregnation, the supercritical impregnation method yielded loading up to 485 mgdrug/gsilica in 120 min of impregnation duration, at 16 MPa and 308 K, with a low degree of crystallinity (about 1%) comparable to the crystallinity observed via the solvent method. In addition to the enhancement of impregnation efficiency, the supercritical route provides a solvent-free alternative for impregnation. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Prototype Development of a Responsive Emotive Sensing System (DRESS) to aid older persons with dementia to dress independently

    PubMed Central

    Mahoney, Diane Feeney; Burleson, Winslow; Lozano, Cecil; Ravishankar, Vijay; Mahoney, Edward Leo

    2015-01-01

    Background Prior research has critiqued the lack of attention to the stressors associated with dementia related dressing issues, stigmatizing patient clothing, and wearable technology challenges. This paper describes the conceptual development and feasibility testing of an innovative ‘smart dresser’ context aware affective system (DRESS) to enable dressing by people with moderate memory loss through individualized audio and visual task prompting in real time. Methods Mixed method feasibility study involving qualitative focus groups with 25 Alzheimer’s family caregivers experiencing dressing difficulties to iteratively inform system design and a quantitative usability trial with 10 healthy subjects in a controlled laboratory setting to assess validity of technical operations. Results Caregivers voiced the need for tangible dressing assistance to reduce their frustration from time spent in repetitive cueing and power struggles over dressing. They contributed 6 changes that influenced the prototype development, most notably adding a dresser top iPad to mimic a familiar ‘TV screen’ for the audio and visual cueing. DRESS demonstrated promising overall functionality, however the validity of identification of dressing status ranged from 0% for the correct pants dressing to 100% for all shirts dressing scenarios. Adjustments were made to the detection components of the system raising the accuracy of detection of all acted dressing scenarios for pants from 50% to 82%. Conclusions Findings demonstrate family caregiver acceptability of the proposed system, the successful interoperability of the built system’s components, and the system’s ability to interpret correct and incorrect dressing actions in controlled laboratory simulations. Future research will advance the system to the alpha stage and subsequent testing with end users in real world settings. PMID:26321895

  11. Replacement of hazardous chromium impregnating agent from silver/copper/chromium-impregnated active carbon using triethylenediamine to remove hydrogen sulfide, trichloromethane, ammonia, and sulfur dioxide.

    PubMed

    Wu, Li-Chun; Chung, Ying-Chien

    2009-03-01

    Activated carbon (AC) is widely used as an effective adsorbent in many applications, including industrial-scale air purification systems and air filter systems in gas masks. In general, ACs without chemical impregnation are good adsorbents of organic vapors but poor adsorbents of low-molecular-weight or polar gases such as chlorine, sulfur dioxide (SO2), formaldehyde, and ammonia (NH3). Impregnated ACs modified with metallic impregnating agents (ASC-carbons; e.g., copper, chromium, and silver) enhance the adsorbing properties of the ACs for simultaneously removing specific poisonous gases, but disposal of the chromium metal salt used to impregnate the ACs has the potential to result in situations that are toxic to both humans and the environment, thereby necessitating the search for replaceable organic impregnating agents that represent a much lower risk. The aim of this study was to assess the gas removal efficiency of an AC in which the organic impregnating agent triethylenediamine (TEDA) largely replaced the metallic impregnating agent chromium. We assessed batch and continuous adsorption capacities in situ for removing simulated hydrogen sulfide (H2S), trichloromethane (CHCl3), NH3, and SO2 gases. Brunauer-Emmet-Teller measurements and scanning electron microscopy analyses identified the removal mechanism by which TEDA-impregnated AS-carbon (dechromium ASC-carbon) adsorbs gases and determined the removal capacity for H2S, CHCl3, NH3, and SO2 to be 311, 258, 272, and 223 mg/g-C, respectively. These results demonstrate that TEDA-impregnated AS-carbon is significantly more efficient than ASC-carbon in adsorbing these four gases. Organic TEDA-impregnating agents have also been proven to be a reliable and environmental friendly agent and therefore a safe replacement of the hazardous chromium found in conventional ASC-carbon used in removing toxic gases from the airstream.

  12. 21 CFR 169.115 - French dressing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false French dressing. 169.115 Section 169.115 Food and... § 169.115 French dressing. (a) Description. French dressing is the separable liquid food or the..., lecithin, or polyglycerol esters of fatty acids. (d) Nomenclature. The name of the food is “French dressing...

  13. Optimization of the dressing parameters in cylindrical grinding based on a generalized utility function

    NASA Astrophysics Data System (ADS)

    Aleksandrova, Irina

    2016-01-01

    The existing studies, concerning the dressing process, focus on the major influence of the dressing conditions on the grinding response variables. However, the choice of the dressing conditions is often made, based on the experience of the qualified staff or using data from reference books. The optimal dressing parameters, which are only valid for the particular methods and dressing and grinding conditions, are also used. The paper presents a methodology for optimization of the dressing parameters in cylindrical grinding. The generalized utility function has been chosen as an optimization parameter. It is a complex indicator determining the economic, dynamic and manufacturing characteristics of the grinding process. The developed methodology is implemented for the dressing of aluminium oxide grinding wheels by using experimental diamond roller dressers with different grit sizes made of medium- and high-strength synthetic diamonds type ??32 and ??80. To solve the optimization problem, a model of the generalized utility function is created which reflects the complex impact of dressing parameters. The model is built based on the results from the conducted complex study and modeling of the grinding wheel lifetime, cutting ability, production rate and cutting forces during grinding. They are closely related to the dressing conditions (dressing speed ratio, radial in-feed of the diamond roller dresser and dress-out time), the diamond roller dresser grit size/grinding wheel grit size ratio, the type of synthetic diamonds and the direction of dressing. Some dressing parameters are determined for which the generalized utility function has a maximum and which guarantee an optimum combination of the following: the lifetime and cutting ability of the abrasive wheels, the tangential cutting force magnitude and the production rate of the grinding process. The results obtained prove the possibility of control and optimization of grinding by selecting particular dressing parameters.

  14. [Effectiveness of the transparent sterile dressing vs standard to fix the peripheral venous catheter (PVC) on the incidence of phlebitis. A randomized controlled trial].

    PubMed

    Forni, Cristiana; D'Alessandro, Fabio; Gambino, Orazio; Amodeo, Alfredo; Pignotti, Elettra; Zanotti, Enrichetta; Tremosini, Morena; Trofa, Carmela; Sabattini, Tania; Matino, Federica; Genco, Rossana; Schiavone, Miguel; Bombino, Caterina; Mini, Sandra; Rocchegiani, Laura; Notarnicola, Teresa; Capezzali, Daniela; Boschi, Rita; Loro, Loretta

    2012-01-01

    Effectiveness of the transparent sterile dressing vs standard to fix the peripheral venous catheter (PVC), on the incidence of phlebitis. A randomized controlled trial. The type of dressing could contribute to the incidence of phlebitis, infiltration and accidental removals but the results of the studies are contrasting and samples are limited. To compare the effectiveness of a transparent polyurethane sterile dressing on the rate of phlebitis associated to peripheral venous catheter (PVC) vs a non sterile sticking plaster in use in current practice (standard dressing). Randomized controlled trial. Participants. 1061 PVCs (703 patients, adults and children) at a research orthopedic hospital in the north of Italy; 540 PVCs allocated to receive the sterile and 521 the standard dressing. 96 PVCs were excluded for phlebitis, 48 (9.6%) in the sterile and 48 (10.1%) in the standard dressing group, RR 0.96 (95%CI 0.697 - 1.335). Accidental removal of the PVCs was more frequent with the sterile dressing (9.6% vs 6.3%) but the number of catheters removed without complications was larger in the standard dressing group (48.9% vs 54.9% P=0.0503). Eighty-five PVCs were replaced for detachment of the dressing (50, 9.2% sterile and 35, 6.7% standard dressing). The cheapest transparent sterile dressing costs 32 cents while the standard 9 cents. A sticking non sterile plasters is not influential on the rate of phlebitis and ensures an good fix of the PVC compared the transparent sterile dressing to of polyurethane film.

  15. Stabilized sulfur binding using activated fillers

    DOEpatents

    Kalb, Paul D.; Vagin, Vyacheslav P.; Vagin, Sergey P.

    2015-07-21

    A method of making a stable, sulfur binding composite comprising impregnating a solid aggregate with an organic modifier comprising unsaturated hydrocarbons with at least one double or triple covalent bond between adjacent carbon atoms to create a modifier-impregnated aggregate; heating and drying the modifier-impregnated aggregate to activate the surface of the modifier-impregnated aggregate for reaction with sulfur.

  16. Secondary polymer layered impregnated tile

    NASA Technical Reports Server (NTRS)

    Tran, Huy K. (Inventor); Rasky, Daniel J. (Inventor); Szalai, Christine E. (Inventor); Carroll, Joseph A. (Inventor); Hsu, Ming-ta S. (Inventor)

    2005-01-01

    A low density organic polymer impregnated preformed fibrous ceramic article includes a plurality of layers. A front layer includes ceramic fibers or carbon fibers or combinations of ceramic fibers and carbon fibers, and is impregnated with an effective amount of at least one organic polymer. A middle layer includes polymer impregnated ceramic fibers. A back layer includes ceramic fibers or carbon fibers or combinations of ceramic fibers and carbon fibers, and is impregnated with an effective amount of at least one low temperature pyrolyzing organic polymer capable of decomposing without depositing residues.

  17. Nanofibrillar cellulose wound dressing in skin graft donor site treatment.

    PubMed

    Hakkarainen, T; Koivuniemi, R; Kosonen, M; Escobedo-Lucea, C; Sanz-Garcia, A; Vuola, J; Valtonen, J; Tammela, P; Mäkitie, A; Luukko, K; Yliperttula, M; Kavola, H

    2016-12-28

    Although new therapeutic approaches for burn treatment have made progress, there is still need for better methods to enhance wound healing and recovery especially in severely burned patients. Nanofibrillar cellulose (NFC) has gained attention due to its renewable nature, good biocompatibility and excellent physical properties that are of importance for a range of applications in pharmaceutical and biomedical fields. In the present study, we investigated the potential of a wood based NFC wound dressing in a clinical trial on burn patients. Previously, we have investigated NFC as a topical functionalized wound dressing that contributes to improve wound healing in mice. Wood based NFC wound dressing was tested in split-thickness skin graft donor site treatment for nine burn patients in clinical trials at Helsinki Burn Centre. NFC dressing was applied to split thickness skin graft donor sites. The dressing gradually dehydrated and attached to donor site during the first days. During the clinical trials, physical and mechanical properties of NFC wound dressing were optimized by changing its composition. From patient 5 forward, NFC dressing was compared to commercial lactocapromer dressing, Suprathel® (PMI Polymedics, Germany). Epithelialization of the NFC dressing-covered donor site was faster in comparison to Suprathel®. Healthy epithelialized skin was revealed under the detached NFC dressing. NFC dressing self-detached after 11-21days for patients 1-9, while Suprathel® self-detached after 16-28days for patients 5-9. In comparison studies with patients 5-9, NFC dressing self-detached on average 4days earlier compared with Suprathel®. Lower NFC content in the material was evaluated to influence the enhanced pliability of the dressing and attachment to the wound bed. No allergic reaction or inflammatory response to NFC was observed. NFC dressing did not cause more pain for patients than the traditional methods to treat the skin graft donor sites. Based on the preliminary clinical data, NFC dressing seems to be promising for skin graft donor site treatment since it is biocompatible, attaches easily to wound bed, and remains in place until donor site has renewed. It also detaches from the epithelialized skin by itself. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  18. The design, characteristics, and application of polyurethane dressings using the electrospinning process

    NASA Astrophysics Data System (ADS)

    Kampeerapappun, Piyaporn

    In general, a dressing is used to protect and help heal wounds. There are several types of dressings on the market such as hydrocolloid, hydrogel, and medicated dressings. One technique for making a dressing is electrospinning, which is a very simple procedure used to produce fibers. Due to much smaller fiber-diameters than produced with the conventional technique, the fibers from electrospinning have unique properties: high porosity and high surface areas, which are advantageous for wound healing. In this research, the fibers were electrospun using polyurethane, TecophilicRTM or TecoflexRTM, with various additives. First, multilayer transdermal electrospun dressings, four and five-layers, were developed that allowed for the controlled release of nitric oxide (NO) from a NO2 -/ascorbic acid system encapsulated in polymer nanofibers. The amount of NO released from each wound dressing was investigated. Both the four and five-layer dressings were tested for morphology of fibers, water absorption, nitrite distribution, NO release profile after sterilization by gamma radiation, and stability. In the case of the four-layer transdermal dressing, the dressing was tested in diabetic, periodontal, and cutaneous leishmaniasis patients. Furthermore, the color change of dressing was investigated. TecophilicRTM was also spun with an antimicrobial agent, which was added to the TecophilicRTM solution to electrospin an antimicrobial dressing. The morphology of fibers was tested using an optical microscope and the water absorption, uniformity, and percent extraction of dressing were also determined. In addition, the efficiency of the antimicrobial agent in the dressing was determined according to SN 195920-1994 and ASTM 2149-01. Another NO-releasing dressing was developed employing the NO donor molecules, sodium salt of linear polyethylenimine NONOates (LPEINO-Na) and calcium salt of linear polyethylenimine NONOates (LPEINO-Ca), which were electrospun with TecophilicRTM. The NO release profiles for the LPEINO fibers were generated using a nitric oxide analyzer (NOA) and distribution of the particles in the dressing was examined. Moreover, the amount of NO released after patch storage for 1 and 2 months was determined.

  19. Wet to dry dressing changes

    MedlinePlus

    ... as much gauze or packing gauze. Removing the Old Dressing Follow these steps to remove your dressing: ... sterile gloves. Carefully remove the tape. Remove the old dressing. If it is sticking to your skin, ...

  20. A prospective randomized clinical trial to evaluate methods of postoperative care of hypospadias.

    PubMed

    McLorie, G; Joyner, B; Herz, D; McCallum, J; Bagli, D; Merguerian, P; Khoury, A

    2001-05-01

    Hypospadias repair is a common operation performed by pediatric urologists. Perhaps the greatest variable and source of controversy of postoperative care is the surgical dressing. We hypothesized that using no dressing would achieve surgically comparable results to those traditionally achieved by a postoperative dressing and it would also simplify postoperative parent delivered home care. Accordingly we designed a prospective randomized clinical trial to compare surgical outcome and postoperative care after hypospadias repair in boys with no dressing and those who received 1 of the 2 most common types of dressing. In a 12-month period 120 boys with an average age of 2.2 years underwent primary 1-stage hypospadias repair at a single center with 4 participating surgeons. Repair was performed in 60 boys with proximal and 60 with distal hypospadias on an outpatient basis. Ethics and Internal Review Board approval, and informed consent were obtained. Boys were then prospectively randomized to receive no dressing, an adhesive biomembrane dressing or a compressive wrap dressing. Comprehensive instructions on postoperative care were distributed to all families and a questionnaire was distributed to the parents at the initial followup. Surgical outcome was evaluated and questionnaire responses were analyzed. Fisher's exact test was done to test the significance of differences in surgical outcomes and questionnaire responses. A total of 117 boys completed the prospective randomized trial. Surgical staff withdrew 3 cases from randomized selection to place a dressing for postoperative hemostasis. We obtained 101 questionnaires for response analysis. The type or absence of the dressing did not correlate with the need for repeat procedures, urethrocutaneous fistula, or meatal stenosis or regression. Analysis revealed less narcotic use in the no dressing group and fewer telephone calls to the urology nurse, or on-call resident and/or fellow. These findings were statistically significant. In addition, there were more unscheduled visits to the urology clinic, emergency room or primary physician office by boys with than without a dressing. Furthermore, 29% of the parents were not psychologically prepared to remove the dressing and 12% were so reluctant that the dressing was removed at the urology outpatient clinic. The surgical outcome and rate of adverse events or complications were not compromised without a postoperative dressing. An absent dressing simplified postoperative ambulatory parent delivered home care. We recommend that dressings should be omitted from routine use after hypospadias repair.

  1. Modification of fast-growing Chinese Fir wood with unsaturated polyester resin: Impregnation technology and efficiency

    NASA Astrophysics Data System (ADS)

    Ma, Qing; Zhao, Zijian; Yi, Songlin; Wang, Tianlong

    In this study, Chinese Fir was impregnated with unsaturated polyester resin to enhance its properties. Samples 20 mm × 20 mm × 20 mm in size were split into different sections with epoxy resin and tinfoil and subjected to an impregnation experiment under various parameters. Vacuum degree was -0.04 MPa, -0.06 MPa or -0.08 MPa and vacuum duration was 15 min, 30 min, or 45 min. The results indicated that impregnation weight percent gain is linearly dependent on curing weight percent gain. Vacuum duration appears to have less influence on the curing weight percent gain than vacuum degree, and impregnation was most successful at the transverse section compared to other sections. The optimal impregnation parameters were 30 min modification under -0.08 MPa vacuum followed by 120 min at atmospheric pressure for samples 200 mm × 100 mm × 20 mm in size. Uneven distribution of weight percent gain and cracking during the curing process suggested that 30 min post-processing at -0.09 MPa vacuum was the most effective way to complete the impregnation process. The sample's bending strength and modulus of elasticity increased after impregnation treatment. Bending strength after impregnation without post-processing reached 112.85%, but reached 71.65% with vacuum-processing; modulus of elasticity improved 67.13% and 58.28% without and with post-processing, respectively.

  2. Removal of hydrogen sulfide and sulfur dioxide by carbons impregnated with triethylenediamine.

    PubMed

    Wu, Li-Chun; Chang, Tsu-Hua; Chung, Ying-Chien

    2007-12-01

    Activated carbon (AC) adsorption has long been considered to be a readily available technology for providing protection against exposure to acutely toxic gases. However, ACs without chemical impregnation have proven to be much less efficient than impregnated ACs in terms of gas removal. The impregnated ACs in current use are usually modified with metalloid impregnation agents (ASC-carbons; copper, chromium, or silver) to simultaneously enhance the chemical and physical properties of the ACs in removing specific poisonous gases. These metalloid agents, however, can cause acute poisoning to both humans and the environment, thereby necessitating the search for organic impregnation agents that present a much lower risk. The aim of the study reported here was to assess AC or ASC-carbon impregnated with triethylenediamine (TEDA) in terms of its adsorption capability for simulated hydrogen sulfide (H2S) and sulfur dioxide (SO2) gases. The investigation was undergone in a properly designed laboratory-scale and industrial fume hood evaluation. Using the system reported here, we obtained a significant adsorption: the removal capability for H2S and SO2 was 375 and 229 mg/g-C, respectively. BET measurements, element analysis, scanning electron microscopy, and energy dispersive spectrometry identified the removal mechanism for TEDA-impregnated AC to be both chemical and physical adsorption. Chemical adsorption and oxidation were the primary means by which TEDA-impregnated ASC-carbons removed the simulated gases.

  3. Impregnated active carbons to control atmospheric emissions: influence of impregnation methodology and raw material on the catalytic activity.

    PubMed

    Alvim-Ferraz, Maria C M; Gaspar, Carla M T B

    2005-08-15

    Previous studies have reported the influence of raw material on the catalytic activity of metal oxides impregnated in activated carbons. However, knowledge was as yet quite scarce for impregnation performed before activation. The main objective of the study here reported was the development of such knowledge. Olive stones, pinewood sawdust, nutshells, and almond shells were recycled to prepare the activated carbons. Transition metal oxides (CoO, Co3O4, and CrO3) were impregnated aiming to prepare activated carbons to be used for the complete catalytic oxidation of benzene. When impregnation was performed after activation the impregnated species were deposited on the internal surface, blocking part of the initial porous texture. When impregnation was performed before activation, the metal species acted as catalysts during the activation step, allowing better catalyst distribution on a more well-developed mesoporous texture. Co3O4 was the best catalyst and almond shells were the best support. With this catalyst/support pair a conversion of 90% was possible at 404 K, the lowest temperature of all the carbons studied. Good conversions were obtained at temperatures that guarantee carbon stability (lower than 575 K). It was concluded that activated carbon was a suitable support for metal oxide catalysts aiming for the complete oxidation of benzene, especially when a suitable porous texture is induced, by performing the impregnation step before activation.

  4. An Assistive Technology System that Provides Personalized Dressing Support for People Living with Dementia: Capability Study.

    PubMed

    Burleson, Winslow; Lozano, Cecil; Ravishankar, Vijay; Lee, Jisoo; Mahoney, Diane

    2018-05-01

    Individuals living with advancing stages of dementia (persons with dementia, PWDs) or other cognitive disorders do not have the luxury of remembering how to perform basic day-to-day activities, which in turn makes them increasingly dependent on the assistance of caregivers. Dressing is one of the most common and stressful activities provided by caregivers because of its complexity and privacy challenges posed during the process. In preparation for in-home trials with PWDs, the aim of this study was to develop and evaluate a prototype intelligent system, the DRESS prototype, to assess its ability to provide automated assistance with dressing that can afford independence and privacy to individual PWDs and potentially provide additional freedom to their caregivers (family members and professionals). This laboratory study evaluated the DRESS prototype's capacity to detect dressing events. These events were engaged in by 11 healthy participants simulating common correct and incorrect dressing scenarios. The events ranged from donning a shirt and pants inside out or backwards to partial dressing-typical issues that challenge a PWD and their caregivers. A set of expected detections for correct dressing was prepared via video analysis of all participants' dressing behaviors. In the initial phases of donning either shirts or pants, the DRESS prototype missed only 4 out of 388 expected detections. The prototype's ability to recognize other missing detections varied across conditions. There were also some unexpected detections such as detection of the inside of a shirt as it was being put on. Throughout the study, detection of dressing events was adversely affected by the relatively smaller effective size of the markers at greater distances. Although the DRESS prototype incorrectly identified 10 of 22 cases for shirts, the prototype preformed significantly better for pants, incorrectly identifying only 5 of 22 cases. Further analyses identified opportunities to improve the DRESS prototype's reliability, including increasing the size of markers, minimizing garment folding or occlusions, and optimal positioning of participants with respect to the DRESS prototype. This study demonstrates the ability to detect clothing orientation and position and infer current state of dressing using a combination of sensors, intelligent software, and barcode tracking. With improvements identified by this study, the DRESS prototype has the potential to provide a viable option to provide automated dressing support to assist PWDs in maintaining their independence and privacy, while potentially providing their caregivers with the much-needed respite. ©Winslow Burleson, Cecil Lozano, Vijay Ravishankar, Jisoo Lee, Diane Mahoney. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 01.05.2018.

  5. Evaluation of dressings used with local anaesthetic cream and for peripheral venous cannulation.

    PubMed

    Needham, Rowan; Strehle, Eugen-Matthias

    2008-10-01

    To compare four polyurethane dressings manufactured by two different companies for use in children. Seventy-eight dressings were applied to secure either local anaesthetic creams (n = 62) or intravenous cannulae (n = 16). Each dressing was evaluated for ease of application, security and ease of removal, using a simple scoring system. 84 per cent of Opsite flexigrid and 90 per cent of Tegaderm local anaesthetic cream dressings were rated as easy or very easy to apply. Opsite flexigrid was felt to be more secure, whereas Tegaderm was easier to remove. The Tegaderm cannula dressing was easier to apply than the iv3000 dressing. There was little difference between the two brands, including costs.

  6. "Posh Music Should Equal Posh Dress": An Investigation into the Concert Dress and Physical Appearance of Female Soloists

    ERIC Educational Resources Information Center

    Griffiths, Noola K.

    2010-01-01

    This study investigates the effects of concert dress and physical appearance on perceptions of female classical soloists' musical abilities over a range of genres. Four female violinists were recorded playing three pieces, in four styles of dress of varying formality. Each combination of performer, piece and dress was recorded twice, once as the…

  7. Use of wound dressings with soft silicone adhesive technology.

    PubMed

    Morris, Clare; Emsley, Paulene; Marland, Elizabeth; Meuleneire, Frans; White, Richard

    2009-04-01

    To evaluate how pain, during and in-between dressing changes, is affected by the introduction of Mepilex Border Lite, a wound dressing manufactured by Mölnlycke Health Care using Safetac soft silicone adhesive technology, to the treatment of different types of paediatric wounds/skin injuries. Wounds/skin injuries that met the criteria for inclusion in the study were dressed with Mepilex Border Lite. Patients were followed for six weeks or until their wounds/skin injuries had healed, whichever occurred earlier. At each dressing change, pain severity before and during dressing removal was rated by the patient and the investigator on a scale from zero (no pain at all) to ten (worst pain ever). Other variables measured included: signs of trauma to wound/skin injury and surrounding skin, the proportion of viable/non-viable tissue, the quantity and appearance of exudate, odour, and clinical signs of infection. At the final dressing change, patients and investigators completed questionnaires to rate the dressing performance. Mean pain severity scores were significantly lower (p < or = 0.003) at the first dressing change than at baseline. Over 99.5 per cent of the Mepilex Border Lite dressing changes were reported to be atraumatic and more than half of the wounds healed within the study period. Conformability, ease of use, ease of removal, patient comfort, and overall experience with the dressing were rated as 'good' to 'very good' at the vast majority of final visit evaluations. This study provides further evidence of the ability of dressings with Safetac soft silicone adhesive technology to minimise trauma and pain and demonstrates the ability of Mepilex Border Lite to overcome the clinical challenges associated with the use of dressings on the wounds/skin injuries of paediatric patients.

  8. Study of porous silicon optical waveguides impregnated with organic dyes

    NASA Astrophysics Data System (ADS)

    Pirasteh, P.; Charrier, J.; Dumeige, Y.; Chaillou, A.; Guendouz, M.; Haji, L.

    2007-01-01

    Planar waveguides were made using oxidised porous silicon layers. Then, they were impregnated with Congo Red or Disperse Red 1 dyes. Optical losses were investigated before and after impregnation. In our case, the losses of impregnated waveguides were always higher than those of non-impregnated ones. In order to achieve a better understanding of the origin of these losses, we not only studied the absorbance of solutions which would impregnate the porous layers but also the reflectance spectra of the obtained composite materials. According to the measurements, the increase in losses in the visible spectrum depends on the intrinsic absorption of the dye while in NIR, the increase would be due to an accumulation of dried dye on the surface of the waveguide which would give rise to the surface scattering losses.

  9. A Mathematical Model for Continuous Fiber Reinforced Thermoplastic Composite in Melt Impregnation

    NASA Astrophysics Data System (ADS)

    Ren, Feng; Yu, Yang; Yang, Jianjun; Xin, Chunling; He, Yadong

    2017-06-01

    Through the combination of Reynolds equation and Darcy's law, a mathematical model was established to calculate the pressure distribution in wedge area, which contributed to the forecast effect of processing parameters on impregnation degree of the fiber bundle. The experiments were conducted to verify the capacity of the proposed model with satisfactory results, which means that the model is effective in predicting the influence of processing parameters on impregnation. From the mathematical model, it was known that the impregnation degree of the fiber bundle would be improved by increasing the processing temperature, number and radius of pins, or decreasing the pulling speed and the center distance of pins, which provided a possible solution to the difficulty of melt with high viscosity in melt impregnation and optimization of impregnation processing.

  10. The safety and efficacy of bacterial nanocellulose wound dressing incorporating sericin and polyhexamethylene biguanide: in vitro, in vivo and clinical studies.

    PubMed

    Napavichayanun, Supamas; Yamdech, Rungnapha; Aramwit, Pornanong

    2016-03-01

    In our previous work, we have attempted to develop a novel bacterial nanocellulose wound dressing which composed of both polyhexamethylene biguanide (PHMB) as an antimicrobial agent and sericin as an accelerative wound healing component. The loading sequence and concentration of PHMB and sericin were optimized to provide the wound dressing with the most effective antimicrobial activity and enhanced collagen production. In this study, further in vitro, in vivo, and clinical studies of this novel wound dressing were performed to evaluate its safety, efficacy, and applicability. For the in vitro cytotoxic test with L929 mouse fibroblast cells, our novel dressing was not toxic to the cells and also promoted cell migration as good as the commercially available dressing, possibly due to the component of sericin released. When implanted subcutaneously in rats, the lower inflammation response was observed for the novel dressing implanted, comparing to the commercially available dressing. This might be that the antimicrobial PHMB component of the novel dressing played a role to reduce infection and inflammation reaction. The clinical trial patch test was performed on the normal skin of healthy volunteers to evaluate the irritation effect of the dressing. Our novel dressing did not irritate the skin of any volunteers, as characterized by the normal levels of erythema and melanin and the absence of edema, papule, vesicle, and bullae. Then, the novel dressing was applied for the treatment of full-thickness wounds in rats. The wounds treated with our novel dressing showed significantly lower percentage of wound size and higher extent of collagen formation mainly due to the activity of sericin. We concluded that our novel bacterial nanocellulose incorporating PHMB and sericin was a safe and efficient wound dressing material for further investigation in the wound healing efficacy in clinic.

  11. Dressing the post-Newtonian two-body problem and classical effective field theory

    NASA Astrophysics Data System (ADS)

    Kol, Barak; Smolkin, Michael

    2009-12-01

    We apply a dressed perturbation theory to better organize and economize the computation of high orders of the 2-body effective action of an inspiralling post-Newtonian (PN) gravitating binary. We use the effective field theory approach with the nonrelativistic field decomposition (NRG fields). For that purpose we develop quite generally the dressing theory of a nonlinear classical field theory coupled to pointlike sources. We introduce dressed charges and propagators, but unlike the quantum theory there are no dressed bulk vertices. The dressed quantities are found to obey recursive integral equations which succinctly encode parts of the diagrammatic expansion, and are the classical version of the Schwinger-Dyson equations. Actually, the classical equations are somewhat stronger since they involve only finitely many quantities, unlike the quantum theory. Classical diagrams are shown to factorize exactly when they contain nonlinear worldline vertices, and we classify all the possible topologies of irreducible diagrams for low loop numbers. We apply the dressing program to our post-Newtonian case of interest. The dressed charges consist of the dressed energy-momentum tensor after a nonrelativistic decomposition, and we compute all dressed charges (in the harmonic gauge) appearing up to 2PN in the 2-body effective action (and more). We determine the irreducible skeleton diagrams up to 3PN and we employ the dressed charges to compute several terms beyond 2PN.

  12. Cost of dressings for prevention of sacral pressure ulcers.

    PubMed

    Inoue, Kelly Cristina; Matsuda, Laura Misue

    2016-01-01

    to identify costs of dressings to prevent sacral pressure ulcers in an adult intensive care unit in Paraná, Brazil. secondary analysis study with 25 patients admitted between October 2013 and March 2014, using transparent polyurethane film (n=15) or hydrocolloid dressing (n=10) on the sacral region. The cost of each intervention was based on the unit amount used in each type of dressing, and its purchase price (transparent film = R$15.80, hydrocolloid dressing = R$68.00). the mean cost/patient was R$23.17 for use of transparent film and R$190.40 for use of hydrocolloid dressing. The main reason for changing the dressing was detachment. the transparent film was the most economically advantageous alternative to prevent sacral pressure ulcers in critical care patients. However, additional studies should be carried out including assessment of the effectiveness of both dressings.

  13. Trends for Electron Beam Accelerator Applications in Industry

    NASA Astrophysics Data System (ADS)

    Machi, Sueo

    2011-02-01

    Electron beam (EB) accelerators are major pieces of industrial equipment used for many commercial radiation processing applications. The industrial use of EB accelerators has a history of more than 50 years and is still growing in terms of both its economic scale and new applications. Major applications involve the modification of polymeric materials to create value-added products, such as heat-resistant wires, heat-shrinkable sheets, automobile tires, foamed plastics, battery separators and hydrogel wound dressing. The surface curing of coatings and printing inks is a growing application for low energy electron accelerators, resulting in an environmentally friendly and an energy-saving process. Recently there has been the acceptance of the use of EB accelerators in lieu of the radioactive isotope cobalt-60 as a source for sterilizing disposable medical products. Environmental protection by the use of EB accelerators is a new and important field of application. A commercial plant for the cleaning flue gases from a coal-burning power plant is in operation in Poland, employing high power EB accelerators. In Korea, a commercial plant uses EB to clean waste water from a dye factory.

  14. Iron-impregnated granular activated carbon for arsenic removal from drinking water

    NASA Astrophysics Data System (ADS)

    Chang, Qigang

    A new multi-step iron impregnation method was developed in this study to impregnate GAC with a high amount of iron that possesses desired characteristics: stable, even distribution, and high arsenic adsorption capacity. Research was carried out to investigate the impact of the amount of impregnated iron on arsenic adsorption properties: capacity, affinity, and kinetics. Fe-GACs were characterized in terms of the amount, stability, distribution, morphology, and species of impregnated iron. It was found that a high amount of iron was stably impregnated in GAC. Scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS) analysis demonstrated that the impregnated iron was evenly distributed on the internal surface of GAC. Impregnated iron formed nano-size particles and existed in both crystalline (akaganeite) and amorphous iron. Arsenic adsorption tests were conducted using Fe-GACs with iron content of 1.64--28.90% in a low arsenic concentration that is typical for drinking water treatment. The amount of impregnated iron affects arsenic maximum adsorption capacity (qm) but has little impact on the Langmuir constant h (the affinity of adsorbent for adsorbate). The qm for both As(V) and As(III) adsorptions increased significantly with increase of the amount of impregnated iron up to 13.59%. Further increase of iron amounts caused a gradual decrease of qm for As(V). BET analysis indicated impregnated iron possesses the highest surface area at iron content of 13.59%. A new second-order kinetic model was developed to investigate the impact of the amounts of impregnated iron on arsenic adsorption kinetics. With iron content increased from 1.64% to 28.90%, the intrinsic adsorption rate constants reduced from 4.6x10-2 1/hr to 1.18x10 -3 1/hr, which indicates that impregnated iron slows arsenic intraparticle diffusion rate in Fe-GAC. The decreased arsenic intraparticle diffusion rate was most likely caused by reduced pore size of Fe-GACs. Column tests were conducted to investigate the performance of Fe-GACs in real implementations using groundwater taken from a former superfund site in North Dakota. Fe-GACs can remove arsenic below 10 microg/L and the performance of Fe-GACs was significantly enhanced with increasing empty bed contact time.

  15. Clinical review: Efficacy of antimicrobial-impregnated catheters in external ventricular drainage - a systematic review and meta-analysis.

    PubMed

    Wang, Xiang; Dong, Yan; Qi, Xiang-Qian; Li, Yi-Ming; Huang, Cheng-Guang; Hou, Li-Jun

    2013-07-25

    To assess the efficacy of antimicrobial-impregnated catheters in preventing catheter-related infections during external ventricular drainage (EVD), we performed a meta-analysis and systematic review. We systematically searched Medline, Embase, and the Cochrane Library. All randomized controlled trials (RCTs) and nonrandomized prospective studies (NPSs) related to antimicrobial-impregnated EVD catheters were included. The primary outcome was the rate of cerebrospinal fluid infection (CFI). The secondary outcomes included the rate of time-dependent CFI and catheter bacterial colonization. We further performed subgroup analysis, meta-regression analysis, and microbial spectrum analysis. Four RCTs and four NPSs were included. The overall rate of CFIs was 3.6% in the antimicrobial-impregnated catheter group and 13.7% in the standard catheter group. The pooled data demonstrated that antimicrobial-impregnated catheters were superior to standard catheters in lowering the rate of CFIs (odds ratio (OR) = 0.25, 95% confidence interval (CI) = 0.12 to 0.52, P <0.05). In survival analysis, the 20-day infection rate was significantly reduced with the use of antimicrobial-impregnated catheters (hazard ratio = 0.52, 95% CI = 0.29 to 0.95, P <0.05). Furthermore, a significantly decreased rate of catheter bacterial colonization was noticed for antimicrobial-impregnated catheters (OR = 0.37, 95% CI = 0.21 to 0.64, P <0.05). In subgroup analyses, although significant results remained for RCTs and NPSs, a subgroup difference was revealed (P <0.05). Compared with standard catheters, a significantly lower rate of CFIs was noticed for clindamycin/rifampin-impregnated catheters (OR = 0.27, 95% CI = 0.10 to 0.73, P <0.05) and for minocycline/rifampin-impregnated catheters (OR = 0.11, 95% CI = 0.06 to 0.21, P <0.05). However, no statistical significance was found when compared with silver-impregnated catheters (OR = 0.33, 95% CI = 0.07 to 1.69, P = 0.18). In microbial spectrum analysis, antimicrobial-impregnated catheters were shown to have a lower rate of Gram-positive bacterial infection, particularly the coagulase-negative Staphylococcus. In conclusion, the use of antimicrobial-impregnated EVD catheters could be beneficial for the prevention of CFI and catheter bacterial colonization. Although antibiotic-coated catheters seem to be effective, no sufficient evidence supports the efficacy of silver-impregnated catheters.

  16. Clinical review: Efficacy of antimicrobial-impregnated catheters in external ventricular drainage - a systematic review and meta-analysis

    PubMed Central

    2013-01-01

    To assess the efficacy of antimicrobial-impregnated catheters in preventing catheter-related infections during external ventricular drainage (EVD), we performed a meta-analysis and systematic review. We systematically searched Medline, Embase, and the Cochrane Library. All randomized controlled trials (RCTs) and nonrandomized prospective studies (NPSs) related to antimicrobial-impregnated EVD catheters were included. The primary outcome was the rate of cerebrospinal fluid infection (CFI). The secondary outcomes included the rate of time-dependent CFI and catheter bacterial colonization. We further performed subgroup analysis, meta-regression analysis, and microbial spectrum analysis. Four RCTs and four NPSs were included. The overall rate of CFIs was 3.6% in the antimicrobial-impregnated catheter group and 13.7% in the standard catheter group. The pooled data demonstrated that antimicrobial-impregnated catheters were superior to standard catheters in lowering the rate of CFIs (odds ratio (OR) = 0.25, 95% confidence interval (CI) = 0.12 to 0.52, P <0.05). In survival analysis, the 20-day infection rate was significantly reduced with the use of antimicrobial-impregnated catheters (hazard ratio = 0.52, 95% CI = 0.29 to 0.95, P <0.05). Furthermore, a significantly decreased rate of catheter bacterial colonization was noticed for antimicrobial-impregnated catheters (OR = 0.37, 95% CI = 0.21 to 0.64, P <0.05). In subgroup analyses, although significant results remained for RCTs and NPSs, a subgroup difference was revealed (P <0.05). Compared with standard catheters, a significantly lower rate of CFIs was noticed for clindamycin/rifampin-impregnated catheters (OR = 0.27, 95% CI = 0.10 to 0.73, P <0.05) and for minocycline/rifampin-impregnated catheters (OR = 0.11, 95% CI = 0.06 to 0.21, P <0.05). However, no statistical significance was found when compared with silver-impregnated catheters (OR = 0.33, 95% CI = 0.07 to 1.69, P = 0.18). In microbial spectrum analysis, antimicrobial-impregnated catheters were shown to have a lower rate of Gram-positive bacterial infection, particularly the coagulase-negative Staphylococcus. In conclusion, the use of antimicrobial-impregnated EVD catheters could be beneficial for the prevention of CFI and catheter bacterial colonization. Although antibiotic-coated catheters seem to be effective, no sufficient evidence supports the efficacy of silver-impregnated catheters. PMID:23890254

  17. Topical petrolatum gel alone versus topical silver sulfadiazine with standard gauze dressings for the treatment of superficial partial thickness burns in adults: a randomized controlled trial.

    PubMed

    Genuino, Glenn Angelo S; Baluyut-Angeles, Kathrina Victoria; Espiritu, Andre Paolo T; Lapitan, Marie Carmela M; Buckley, Brian S

    2014-11-01

    Non-extensive superficial partial thickness burns constitute a major proportion of burns. Conventional treatment involves regular changing of absorptive dressings including the application of a topical antimicrobial, commonly silver sulfadiazine. A systematic review has found insufficient evidence to support or refute such antimicrobial prophylaxis. Another review compared silver sulfadiazine dressings with other occlusive and non-antimicrobial dressings and found insufficient evidence to guide practice. Other research has suggested that dressings with petrolatum gel are as effective as silver sulfadiazine. Single-center, randomized, controlled parallel group trial comparing conventional silver sulfadiazine dressings with treatment with petrolatum gel alone. Consenting adults 18-45 years old with superficial partial thickness burns≤10% total body surface area seen within 24h of the injury were randomized to daily dressing either with petrolatum gel without top dressings or conventional silver sulfadiazine treatment with gauze dressings. Primary outcomes were blinded assessment of time to complete re-epithelialization, wound infection or allergic contact dermatitis. Secondary outcomes included assessment of ease, time and pain of dressing changes. 26 patients were randomized to petrolatum and 24 to silver sulfadiazine dressings. Follow up data available for 19 in each group. Mean time to re-epithelialization was 6.2 days (SD 2.8) in the petrolatum group and 7.8 days (SD 2.1) in the silver sulfadiazine group (p=0.050). No wound infection or dermatitis was observed in either group. Scores for adherence to wound, ease of dressing removal and time required to change dressings were significantly better in the petrolatum treatment arm (p<0.01). Petrolatum gel without top dressings may be at least as effective as silver sulfadiazine gauze dressings with regard to time to re-epithelialization, and incidence of infection and allergic contact dermatitis. Petrolatum gel appears to be an effective, affordable and widely available alternative in the treatment of minor superficial partial thickness burns in adults. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  18. Effects of a just-in-time educational intervention placed on wound dressing packages: a multicenter randomized controlled trial.

    PubMed

    Kent, Dea J

    2010-01-01

    I compared the effects of a just-in-time educational intervention (educational materials for dressing application attached to the manufacturer's dressing package) to traditional wound care education on reported confidence and dressing application in a simulated model. Nurses from a variety of backgrounds were recruited for this study. The nurses possessed all levels of education ranging from licensed practical nurse to master of science in nursing. Both novice and seasoned nurses were included, with no stipulations regarding years of nursing experience. Exclusion criteria included nurses who spent less than 50% of their time in direct patient care and nurses with advanced wound care training and/or certification (CWOCN, CWON). Study settings included community-based acute care facilities, critical access hospitals, long-term care facilities, long-term acute care facilities, and home care agencies. No level 1 trauma centers were included in the study for geographical reasons. Participants were randomly allocated to control or intervention groups. Each participant completed the Kent Dressing Confidence Assessment tool. Subjects were then asked to apply the dressing to a wound model under the observation of either the principal investigator or a trained observer, who scored the accuracy of dressing application according to established criteria. None of the 139 nurses who received traditional dressing packaging were able to apply the dressing to a wound model correctly. In contrast, 88% of the nurses who received the package with the educational guide attached to it were able to apply the dressing to a wound model correctly (χ2 = 107.22, df = 1, P = .0001). Nurses who received the dressing package with the attached educational guide agreed that this feature gave them confidence to correctly apply the dressing (88%), while no nurse agreed that the traditional package gave him or her the confidence to apply the dressing correctly (χ2 = 147.47, df = 4, P < .0001). A just-in-time education intervention improved nurses' confidence when applying an unfamiliar dressing and accuracy of application when applying the dressing to a simulated model compared to traditional wound care education.

  19. Oxidized Regenerated Cellulose/Collagen Dressings: Review of Evidence and Recommendations.

    PubMed

    Wu, Stephanie; Applewhite, Andrew J; Niezgoda, Jeffrey; Snyder, Robert; Shah, Jayesh; Cullen, Breda; Schultz, Gregory; Harrison, Janis; Hill, Rosemary; Howell, Melania; Speyrer, Marcus; Utra, Howard; de Leon, Jean; Lee, Wayne; Treadwell, Terry

    2017-11-01

    Healthcare systems are being challenged to manage increasing numbers of nonhealing wounds. Wound dressings are one of the first lines of defense in wound management, and numerous options exist. The oxidized regenerated cellulose (ORC)/collagen dressing may offer healthcare providers a robust and cost-effective tool for use in a variety of wounds. A multidisciplinary panel meeting was convened to discuss the use of ORC/collagen dressings in wound care and provide practice recommendations. A literature search was conducted to provide a brief review of the peer-reviewed studies published between January 2000 and March 2016 to inform the meeting. A 2-day panel meeting convened in February 2017. Healthcare providers with experience using ORC/collagen dressings. This multidisciplinary panel of 15 experts in wound healing included podiatrists, wound care specialists (doctors, certified wound care nurses, and research scientists), and an orthopedist. The literature search identified 58 articles, a majority of which were low levels of evidence (69.3% were level 3 or lower). Panel members identified wound types, such as abrasions, burns, stalled wounds, diabetic foot ulcers, and pressure injuries, where ORC/collagen dressing use could be beneficial. Panel members then provided recommendations and technical pearls for the use of ORC/collagen dressings in practice. Barriers to ORC/collagen dressing use were discussed, and potential resolutions were offered. An ORC/collagen dressing can be a critical tool for clinicians to help manage a variety of wounds. Clinical and economic studies comparing standard-of-care dressings and plain collagen dressings to ORC/collagen dressings are needed.

  20. Oxidized Regenerated Cellulose/Collagen Dressings: Review of Evidence and Recommendations

    PubMed Central

    Wu, Stephanie; Applewhite, Andrew J.; Niezgoda, Jeffrey; Snyder, Robert; Shah, Jayesh; Cullen, Breda; Schultz, Gregory; Harrison, Janis; Hill, Rosemary; Howell, Melania; Speyrer, Marcus; Utra, Howard; de Leon, Jean; Lee, Wayne; Treadwell, Terry

    2017-01-01

    ABSTRACT OBJECTIVE: Healthcare systems are being challenged to manage increasing numbers of nonhealing wounds. Wound dressings are one of the first lines of defense in wound management, and numerous options exist. The oxidized regenerated cellulose (ORC)/collagen dressing may offer healthcare providers a robust and cost-effective tool for use in a variety of wounds. DESIGN: A multidisciplinary panel meeting was convened to discuss the use of ORC/collagen dressings in wound care and provide practice recommendations. A literature search was conducted to provide a brief review of the peer-reviewed studies published between January 2000 and March 2016 to inform the meeting. SETTING: A 2-day panel meeting convened in February 2017. PARTICIPANTS: Healthcare providers with experience using ORC/collagen dressings. This multidisciplinary panel of 15 experts in wound healing included podiatrists, wound care specialists (doctors, certified wound care nurses, and research scientists), and an orthopedist. RESULTS: The literature search identified 58 articles, a majority of which were low levels of evidence (69.3% were level 3 or lower). Panel members identified wound types, such as abrasions, burns, stalled wounds, diabetic foot ulcers, and pressure injuries, where ORC/collagen dressing use could be beneficial. Panel members then provided recommendations and technical pearls for the use of ORC/collagen dressings in practice. Barriers to ORC/collagen dressing use were discussed, and potential resolutions were offered. CONCLUSIONS: An ORC/collagen dressing can be a critical tool for clinicians to help manage a variety of wounds. Clinical and economic studies comparing standard-of-care dressings and plain collagen dressings to ORC/collagen dressings are needed. PMID:29049055

  1. Economics of pressure-ulcer care: review of the literature on modern versus traditional dressings.

    PubMed

    San Miguel, L; Torra i Bou, J E; Verdú Soriano, J

    2007-01-01

    Published evidence suggests that some of the benefits of modern dressings--longer wear times and less frequent dressing changes--make them more cost-effective than traditional gauze dressings in pressure ulcer management.

  2. An Assistive Technology System that Provides Personalized Dressing Support for People Living with Dementia: Capability Study

    PubMed Central

    Lozano, Cecil; Ravishankar, Vijay; Lee, Jisoo; Mahoney, Diane

    2018-01-01

    Background Individuals living with advancing stages of dementia (persons with dementia, PWDs) or other cognitive disorders do not have the luxury of remembering how to perform basic day-to-day activities, which in turn makes them increasingly dependent on the assistance of caregivers. Dressing is one of the most common and stressful activities provided by caregivers because of its complexity and privacy challenges posed during the process. Objective In preparation for in-home trials with PWDs, the aim of this study was to develop and evaluate a prototype intelligent system, the DRESS prototype, to assess its ability to provide automated assistance with dressing that can afford independence and privacy to individual PWDs and potentially provide additional freedom to their caregivers (family members and professionals). Methods This laboratory study evaluated the DRESS prototype’s capacity to detect dressing events. These events were engaged in by 11 healthy participants simulating common correct and incorrect dressing scenarios. The events ranged from donning a shirt and pants inside out or backwards to partial dressing—typical issues that challenge a PWD and their caregivers. Results A set of expected detections for correct dressing was prepared via video analysis of all participants’ dressing behaviors. In the initial phases of donning either shirts or pants, the DRESS prototype missed only 4 out of 388 expected detections. The prototype’s ability to recognize other missing detections varied across conditions. There were also some unexpected detections such as detection of the inside of a shirt as it was being put on. Throughout the study, detection of dressing events was adversely affected by the relatively smaller effective size of the markers at greater distances. Although the DRESS prototype incorrectly identified 10 of 22 cases for shirts, the prototype preformed significantly better for pants, incorrectly identifying only 5 of 22 cases. Further analyses identified opportunities to improve the DRESS prototype’s reliability, including increasing the size of markers, minimizing garment folding or occlusions, and optimal positioning of participants with respect to the DRESS prototype. Conclusions This study demonstrates the ability to detect clothing orientation and position and infer current state of dressing using a combination of sensors, intelligent software, and barcode tracking. With improvements identified by this study, the DRESS prototype has the potential to provide a viable option to provide automated dressing support to assist PWDs in maintaining their independence and privacy, while potentially providing their caregivers with the much-needed respite. PMID:29716885

  3. Apparatus for coating and impregnating filament with resin

    DOEpatents

    Robinson, S.C.; Pollard, R.E.

    1986-12-17

    The present invention is directed to an apparatus for evenly coating and impregnating a filament with binder material. Dimension control and repeatability of the coating and impregnating characteristics are obtained with the apparatus.

  4. Effects of adhesive dressings on stratum corneum conductance.

    PubMed

    Cavallini, Maurizio; Gazzola, Riccardo; Vaienti, Luca

    2012-05-01

    Stratum corneum is a fundamental layer of epidermis. It acts as a barrier, with antimicrobial features, regulating skin permeability and integrity as well. Adhesive dressings and their removal could alter this layer, affecting cutaneous water balance and lipid composition of stratum corneum. These changes could be monitored by measurement of cutaneous hydration. Ninety-two patients affected by wounds dressed with adhesive tapes or plasters have been studied. Measurement of skin conductance under tape/plaster and in the surrounding healthy skin, immediately after removal of dressing has been performed. Dressing age, wound localization, and characteristics were also considered. Adhesive dressings alter significantly stratum corneum conductance. Although healthy skin hydration has significant variations throughout the body, cutaneous conductance under adhesive dressing in different areas displays no significative changes. Moreover, the increase in hydration due to adhesive tapes/plasters showed no association with wound dehiscence. Adhesive dressings cause a significative increase in stratum corneum conductance, acting as a barrier to apocrine secretions. Although different hydration levels have been observed in healthy skin throughout the body, no difference exists under adhesive dressing among different regions, suggesting no contraindications in their employment throughout the body. Increase in cutaneous hydration showed no correlations with wound dehiscence, thus confirming safety and practicality of these dressings. © 2011 John Wiley & Sons A/S.

  5. The Effect of Virtual Reality Distraction on Pain Relief During Dressing Changes in Children with Chronic Wounds on Lower Limbs.

    PubMed

    Hua, Yun; Qiu, Rong; Yao, Wen-Yan; Zhang, Qin; Chen, Xiao-Li

    2015-10-01

    It has been demonstrated that patients with chronic wounds experience the most pain during dressing changes. Currently, researchers focus mostly on analgesics and appropriate dressing materials to relieve pain during dressing changes of chronic wounds. However, the effect of nonpharmacologic interventions, such as virtual reality distraction, on pain management during dressing changes of pediatric chronic wounds remains poorly understood. To investigate the effect of virtual reality distraction on alleviating pain during dressing changes in children with chronic wounds on their lower limbs. A prospective randomized study. A pediatric center in a tertiary hospital. Sixty-five children, aged from 4 to 16 years, with chronic wounds on their lower limbs. Pain and anxiety scores during dressing changes were recorded by using the Wong-Baker Faces picture scale, visual analogue scale, and pain behavior scale, as well as physiological measurements including pulse rate and oxygen saturation. Time length of dressing change was recorded. Virtual reality distraction significantly relieved pain and anxiety scores during dressing changes and reduced the time length for dressing changes as compared to standard distraction methods. The use of virtual reality as a distraction tool in a pediatric ward offered superior pain reduction to children as compared to standard distractions. This device can potentially improve clinical efficiency by reducing length time for dressing changes. Copyright © 2015 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.

  6. An Inexpensive Bismuth-Petrolatum Dressing for Treatment of Burns

    PubMed Central

    Chattopadhyay, Arhana; Chang, Kathleen; Nguyen, Khoa; Galvez, Michael G.; Legrand, Anais; Davis, Christopher; McGoldrick, Rory; Long, Chao; Pham, Hung

    2016-01-01

    Background: Xeroform remains the current standard for treating superficial partial-thickness burns but can be prohibitively expensive in developing countries with prevalent burn injuries. This study (1) describes the production of an alternative low-cost dressing and (2) compares the alternative dressing and Xeroform using the metrics of cost-effectiveness, antimicrobial activity, and biocompatibility in vitro, and wound healing in vivo. Methods: To produce the alternative dressing, 3% bismuth tribromophenate powder was combined with petroleum jelly by hand and applied to Kerlix gauze. To assess cost-effectiveness, the unit costs of Xeroform and components of the alternative dressing were compared. To assess antimicrobial properties, the dressings were placed on agar plated with Escherichia coli and the Kirby-Bauer assay performed. To assess biocompatibility, the dressings were incubated with human dermal fibroblasts and cells stained with methylene blue. To assess in vivo wound healing, dressings were applied to excisional wounds on rats and the rate of re-epithelialization calculated. Results: The alternative dressing costs 34% of the least expensive brand of Xeroform. Antimicrobial assays showed that both dressings had similar bacteriostatic effects. Biocompatibility assays showed that there was no statistical difference (P < 0.05) in the cytotoxicity of Xeroform, alternative dressing, and Kerlix gauze. Finally, the in vivo healing model showed no statistical difference (P < 0.05) in mean re-epithelialization time between Xeroform (13.0 ± 1.6 days) and alternative dressing (13.5 ± 1.0 days). Conclusions: Xeroform is biocompatible, reduces infection, and enhances healing of burn wounds by preventing desiccation and mechanical trauma. Handmade petrolatum gauze may be a low-cost replacement for Xeroform. Future studies will focus on clinical trials in burn units. PMID:27482485

  7. Comparison of three different dressings for partial thickness burns in children: study protocol for a randomised controlled trial.

    PubMed

    Gee Kee, Emma; Kimble, Roy M; Cuttle, Leila; Stockton, Kellie

    2013-11-25

    In the paediatric population, pain and distress associated with burn injuries during wound care procedures remain a constant challenge. Although silver dressings are the gold standard for burn care in Australasia, very few high-level trials have been conducted that compare silver dressings to determine which will provide the best level of care clinically. Therefore, for paediatric patients in particular, identifying silver dressings that are associated with lower levels of pain and rapid wound re-epithelialisation is imperative. This study will determine whether there is a difference in time to re-epithelialisation and pain and distress experienced during wound care procedures among Acticoat™, Acticoat™ combined with Mepitel™ and Mepilex Ag™ dressings for acute, paediatric partial thickness burns. Children aged 0 to 15 years with an acute partial thickness (superficial partial to deep partial thickness inclusive) burn injury and a burn total body surface area of ≤ 10% will be eligible for the trial. Patients will be randomised to one of the three dressing groups: (1) Acticoat™ or (2) Acticoat™ combined with Mepitel™ or (3) Mepilex Ag™. A minimum of 28 participants will be recruited for each treatment group. Primary measures of pain, distress and healing will be repeated at each dressing change until complete wound re-epithelialisation occurs or skin grafting is required. Additional data collected will include infection status at each dressing change, physical function, scar outcome and scar management requirements, cost effectiveness of each dressing and staff perspectives of the dressings. The results of this study will determine the effects of three commonly used silver and silicone burn dressing combinations on the rate of wound re-epithelialisation and pain experienced during dressing procedures in acute, paediatric partial thickness burn injuries. Australian New Zealand Clinical Trials Registry ACTRN12613000105741.

  8. Prospective randomized controlled trial: fibrin sealant reduces split skin graft donor-site pain.

    PubMed

    Healy, Ciaran; Greig, Aina V H; Murphy, Adrian D; Powell, Christopher; Pinder, Richard J; Saour, Samer; Abela, Christopher; Knight, William; Geh, Jenny L C

    2013-07-01

    Pain at split skin graft donor sites is common. Fibrin sealant has been demonstrated to reduce time to hemostasis at wound sites, and patients receiving this treatment were incidentally noted to report less pain. This study aimed to evaluate pain and incapacity in split skin graft donor sites treated with and without fibrin sealant. Fifty patients requiring thigh donor-site split skin grafts were prospectively randomized to receive either a self-adhesive fabric dressing alone or fibrin sealant plus the self-adhesive fabric dressing as primary donor-site dressings. External secondary dressings were the same. Patients were blinded with regard to treatment group. Using visual analogue scales (scored 0 to 5), patients rated their donor-site pain and incapacity for 14 days postoperatively. Secondary endpoints were length of hospital stay and duration of requirement for dressings. Forty patients were included in the study analysis and completed self-reported pain and incapacity scores. Twenty received the fibrin sealant plus self-adhesive fabric dressing and 20 received the fabric dressing only (controls). Patients using the fibrin sealant plus the dressing reported significantly less pain (mean score, 0.42 versus 1.60, p < 0.001) and significantly less incapacity (mean score, 0.48 versus 1.71, p < 0.001). Patients allocated to the fibrin sealant group recorded shorter lengths of stay and faster time to discontinuation of dressing, though statistical significance was not achieved. Patients whose split skin graft donor sites were dressed with fibrin sealant plus self-adhesive fabric dressing experienced significantly less pain and incapacity than patients with self-adhesive fabric dressings alone, allowing a more rapid return to normal activity. Therapeutic, II.

  9. Investigation of adhesion of modern wound dressings: a comparative analysis of 56 different wound dressings.

    PubMed

    Klode, J; Schöttler, L; Stoffels, I; Körber, A; Schadendorf, D; Dissemond, J

    2011-08-01

    In the process of chronic wound care, adhesive wound dressings may cause pain and injury in the wound environment during dressing changes. At present, no standardized test procedures are available for the investigation of adhesion of wound dressings. Therefore, our study aimed to test the adhesion of different wound dressings on steel as well as on healthy skin. Within an open, comparative study, the adhesive areas of 56 wound dressings were investigated. The adhesives were categorized into acrylate (n = 23), silicone (n = 9), hydrocolloid (n = 17) and polyurethane groups (n = 7). Using an especially modified testing machine, the adhesion of the wound dressings was measured on steel as well as on the skin of healthy study participants, in compliance with the European EN 1939:2003 standard. The energy required to remove the wound dressings from human skin, was measured in Newton (N) and the following median values were obtained: hydrocolloid (2.25 N) > acrylate (1.14 N) > polyurethane (0.9 N) > silicone (0.7 N). The subjective pain intensity during the removal of the wound dressings was recorded using the visual analogue scale (VAS) with values ranging from 0 to 10. For hydrocolloid, it was 6.8, for acrylate 4.9, for polyurethane 3.1 and for silicone 2.5 points VAS. In comparison with human skin, the adhesion of wound dressings was significantly higher on steel (P < 0.0001), but was different for the different groups of wound dressings. Moreover, there was a statistically significant correlation between the adhesion and pain intensity (correlation coefficient 0.806; P = 0.01). The knowledge about the widely differing adhesion properties of different wound dressings on the skin of patients should nowadays be considered during the individual selection of the applied products. Based on these data, different types of wound dressings could be developed, guaranteeing a good adhesion and a low traumatic risk when removed. © 2010 The Authors. Journal of the European Academy of Dermatology and Venereology © 2010 European Academy of Dermatology and Venereology.

  10. Impregnation of Ibuprofen into Polycaprolactone using supercritical carbon dioxide

    NASA Astrophysics Data System (ADS)

    Yoganathan, Roshan; Mammucari, Raffaella; Foster, Neil R.

    2010-03-01

    Polycaprolactone (PCL) is a Food and Drug Administration (FDA) approved biodegradable polyester used in tissue engineering applications. Ibuprofen is an anti-inflammatory drug which has good solubility in supercritical CO2 (SCCO2). The solubility of CO2 in PCL allows for the impregnation of CO2-soluble therapeutic agents into the polymer via a supercritical fluid (SCF) process. Polymers impregnated with bio-active compounds are highly desired for medical implants and controlled drug delivery. In this study, the use of CO2 to impregnate PCL with ibuprofen was investigated. The effect of operating conditions on the impregnation of ibuprofen into PCL was investigated over two pressure and two temperature levels, 150bar and 200bar, 35°C and 40 °C, respectively. Polycaprolactone with drug-loadings as high as 27% w/w were obtained. Impregnated samples exhibited controlled drug release profiles over several days.

  11. Drug Reaction with Eosinophilia and Systemic Symptoms (DRESS): A National Analysis of Data from 10-Year Post-marketing Surveillance.

    PubMed

    Renda, Francesca; Landoni, Giovanni; Bertini Malgarini, Renato; Assisi, Alessandro; Azzolini, Maria Luisa; Mucchetti, Marta; Pimpinella, Giuseppe; Pani, Luca

    2015-12-01

    Drug reaction with eosinophilia and systemic symptoms (DRESS) is a rare, severe and potentially fatal cutaneous adverse drug reaction (the mortality rate is up to 10 %) associated with numerous and apparently heterogeneous drugs. The aetiology is unknown. To report Italian cases of DRESS over a 10-year period. We searched the National Pharmacovigilance Network (NPN) for the term 'drug reaction with eosinophilia and systemic symptoms' from 1 January 2004 to 1 January 2014, to identify all reports of DRESS. Each case was checked to avoid duplication. In the NPN, we identified 91 serious cases of DRESS: 68 were spontaneous, still-unpublished reports, while 23 additional cases were derived from screening of the scientific literature, performed by marketing authorization holders. Notably, the single common element linking all cases of DRESS was intake of a drug containing an aromatic ring. Thanks to the largest national DRESS case series ever reported, we were able to hypothesize, for the first time, that there is an association between use of drugs containing an aromatic ring in their chemical structure and DRESS. This might aid understanding of the aetiology of DRESS and facilitate diagnosis.

  12. The multifunctional wound dressing with core-shell structured fibers prepared by coaxial electrospinning

    NASA Astrophysics Data System (ADS)

    Wei, Qilin; Xu, Feiyang; Xu, Xingjian; Geng, Xue; Ye, Lin; Zhang, Aiying; Feng, Zengguo

    2016-06-01

    The non-woven wound dressing with core-shell structured fibers was prepared by coaxial electrospinning. The polycaprolactone (PCL) was electrospun as the fiber's core to provide mechanical strength whereas collagen was fabricated into the shell in order to utilize its good biocompatibility. Simultaneously, the silver nanoparticles (Ag-NPs) as anti-bacterial agent were loaded in the shell whereas the vitamin A palmitate (VA) as healing-promoting drug was encapsulated in the core. Resulting from the fiber's core-shell structure, the VA released from the core and Ag-NPs present in the shell can endow the dressing both heal-promoting and anti-bacteria ability simultaneously, which can greatly enhance the dressing's clinical therapeutic effect. The dressing can maintain high swelling ratio of 190% for 3 d indicating its potential application as wet dressing. Furthermore, the dressing's anti-bacteria ability against Staphylococcus aureus was proved by in vitro anti-bacteria test. The in vitro drug release test showed the sustainable release of VA within 72 h, while the cell attachment showed L929 cells can well attach on the dressing indicating its good biocompatibility. In conclusion, the fabricated nanofibrous dressing possesses multiple functions to benefit wound healing and shows promising potential for clinical application.

  13. 21 CFR 169.150 - Salad dressing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Salad dressing. 169.150 Section 169.150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION FOOD DRESSINGS AND FLAVORINGS Requirements for Specific Standardized Food Dressings and Flavorings...

  14. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile device...

  15. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile device...

  16. 21 CFR 169.115 - French dressing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 2 2011-04-01 2011-04-01 false French dressing. 169.115 Section 169.115 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION FOOD DRESSINGS AND FLAVORINGS Requirements for Specific Standardized Food Dressings and Flavorings...

  17. 21 CFR 169.150 - Salad dressing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 2 2011-04-01 2011-04-01 false Salad dressing. 169.150 Section 169.150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION FOOD DRESSINGS AND FLAVORINGS Requirements for Specific Standardized Food Dressings and Flavorings...

  18. Impact of School Uniforms on Student Discipline and the Learning Climate: A Comparative Case Study of Two Middle Schools with Uniform Dress Codes and Two Middle Schools without Uniform Dress Codes

    ERIC Educational Resources Information Center

    Dulin, Charles Dewitt

    2016-01-01

    The purpose of this research is to evaluate the impact of uniform dress codes on a school's climate for student behavior and learning in four middle schools in North Carolina. The research will compare the perceptions of parents, teachers, and administrators in schools with uniform dress codes against schools without uniform dress codes. This…

  19. Aquacel(®) Ag dressing versus Acticoat™ dressing in partial thickness burns: a prospective, randomized, controlled study in 100 patients. Part 1: burn wound healing.

    PubMed

    Verbelen, Jozef; Hoeksema, Henk; Heyneman, Alexander; Pirayesh, Ali; Monstrey, Stan

    2014-05-01

    Studies comparing contemporary silver dressings in burns are scarce. In a prospective, randomized, controlled study, counting 50 patients/research group, we compared two frequently used silver dressings, Acticoat™ and Aquacel(®) Ag, in the management of partial thickness burns with a predicted healing time between 7 and 21 days as assessed by laser Doppler imaging between 48 and 72h after burn. Variables investigated were related to baseline research group characteristics, wound healing, bacteriology, economics, nurse, and patient experience. Both research groups were comparably composed taking into account gender, age and burn characteristics. Similar results were obtained as to healing time and bacterial control with both silver dressings. A statistically significant difference in favor of the Aquacel(®) Ag dressing was found for average ease of use (p<0.001), average ease of application (p=0.001), patient pain (p<0.001), patient comfort with the dressing (p=0.017), silver staining (p<0.001), and cost effectiveness (p<0.001). Both silver dressings resulted in comparable healing times and bacterial control but the Aquacel(®) Ag dressing significantly increased comfort for patients as well as nurses and was significantly more cost-effective than the Acticoat™ dressing for the given indication. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  20. The wound-healing effects of a next-generation anti-biofilm silver Hydrofiber wound dressing on deep partial-thickness wounds using a porcine model.

    PubMed

    Davis, Stephen C; Li, Jie; Gil, Joel; Valdes, Jose; Solis, Michael; Higa, Alex; Bowler, Philip

    2018-06-11

    Topical antimicrobials are widely used to control wound bioburden and facilitate wound healing; however, the fine balance between antimicrobial efficacy and non-toxicity must be achieved. This study evaluated whether an anti-biofilm silver-containing wound dressing interfered with the normal healing process in non-contaminated deep partial thickness wounds. In an in-vivo porcine wound model using 2 pigs, 96 wounds were randomly assigned to 1 of 3 dressing groups: anti-biofilm silver Hydrofiber dressing (test), silver Hydrofiber dressing (control), or polyurethane film dressing (control). Wounds were investigated for 8 days, and wound biopsies (n = 4) were taken from each dressing group, per animal, on days 2, 4, 6, and 8 after wounding and evaluated using light microscopy. No statistically significant differences were observed in the rate of reepithelialisation, white blood cell infiltration, angiogenesis, or granulation tissue formation following application of the anti-biofilm silver Hydrofiber dressing versus the 2 control dressings. Overall, epithelial thickness was similar between groups. Some differences in infiltration of specific cell types were observed between groups. There were no signs of tissue necrosis, fibrosis, or fatty infiltration in any group. An anti-biofilm silver Hydrofiber wound dressing did not cause any notable interference with normal healing processes. © 2018 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  1. 21 CFR 878.4018 - Hydrophilic wound dressing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydrophilic wound dressing. 878.4018 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing. (a) Identification. A hydrophilic wound dressing is a sterile or non-sterile device intended to cover...

  2. 21 CFR 878.4018 - Hydrophilic wound dressing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydrophilic wound dressing. 878.4018 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing. (a) Identification. A hydrophilic wound dressing is a sterile or non-sterile device intended to cover...

  3. Rationale for Student Dress Codes: A Review of School Handbooks

    ERIC Educational Resources Information Center

    Freeburg, Elizabeth W.; Workman, Jane E.; Lentz-Hees, Elizabeth S.

    2004-01-01

    Through dress codes, schools establish rules governing student appearance. This study examined stated rationales for dress and appearance codes in secondary school handbooks; 182 handbooks were received. Of 150 handbooks containing a rationale, 117 related dress and appearance regulations to students' right to a non-disruptive educational…

  4. 21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hydrogel wound dressing and burn dressing. 878.4022 Section 878.4022 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4022...

  5. 21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hydrogel wound dressing and burn dressing. 878.4022 Section 878.4022 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4022...

  6. 21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hydrogel wound dressing and burn dressing. 878.4022 Section 878.4022 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4022...

  7. Bio-inspired surfactant assisted nano-catalyst impregnation of Solid-Oxide Fuel Cell (SOFC) electrodes

    DOE PAGES

    Ozmen, Ozcan; Zondlo, John W.; Lee, Shiwoo; ...

    2015-11-02

    A bio-inspired surfactant was utilized to assist in the efficient impregnation of a nano-CeO₂ catalyst throughout both porous Solid Oxide Fuel Cells (SOFC’s) electrodes simultaneously. The process included the initial modification of electrode pore walls with a polydopamine film. The cell was then submersed into a cerium salt solution. The amount of nano-CeO₂ deposited per impregnation step increased by 3.5 times by utilizing this two-step protocol in comparison to a conventional drip impregnation method. The impregnated cells exhibited a 20% higher power density than a baseline cell without the nano-catalyst at 750°C (using humid H₂ fuel).

  8. A rare manifestation of burns after lightning strike in rural Ghana: a case report.

    PubMed

    Apanga, Paschal Awingura; Azumah, John Atigiba; Yiranbon, Joseph Bayewala

    2017-07-25

    Lightning is a natural phenomenon that mostly affects countries in the tropical and subtropical regions of the globe, including Ghana. Lightning strikes pose a global public health issue. Although strikes to humans are uncommon, it is associated with high morbidity and mortality. We present a case of a 10-year-old Ghanaian girl who got second-degree burns after being struck by lightning. She was put on an intravenous broad-spectrum antibiotic (ceftriaxone), Ringer's lactate, and her burns were dressed with sterile gauze impregnated with Vaseline (petroleum jelly) and silver sulfadiazine ointment. There was marked improvement on the 16 th day of treatment despite the lack in capacity of the hospital to carry out some laboratory diagnostic tests. On the 21 st day of treatment, the burns were completely healed without scars and contractures. This is evidence of burns due to lightning strike, despite its rare occurrence. This report will help inform those in doubt, particularly in communities where lightning injuries are associated with widespread superstition. The case report also revealed how rural healthcare can be challenging amid a lack of basic diagnostic equipment and logistics. However, in resource-limited settings, Vaseline (petroleum jelly) and silver sulfadiazine could be used in the treatment of burns.

  9. Reverse Micelle Synthesis and Characterization of Supported Pt/Ni Bimetallic Catalysts on gamma-Al2O3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    B Cheney; J Lauterbach; J Chen

    2011-12-31

    Reverse micelle synthesis was used to improve the nanoparticle size uniformity of bimetallic Pt/Ni nanoparticles supported on {gamma}-Al{sub 2}O{sub 3}. Two impregnation methods were investigated to optimize the use of the micelle method: (1) step-impregnation, where Ni nanoparticles were chemically reduced in microemulsion and then supported, followed by Pt deposition using incipient wetness impregnation, and (2) co-impregnation, where Ni and Pt were chemically reduced simultaneously in microemulsion and then supported. Transmission electron microscopy (TEM) was used to characterize the particle size distribution. Atomic absorption spectroscopy (AAS) was used to perform elemental analysis of bimetallic catalysts. Extended X-ray absorption fine structuremore » (EXAFS) measurements were utilized to confirm the formation of the Pt-Ni bimetallic bond in the step-impregnated catalyst. CO pulse chemisorption and Fourier transform infrared spectroscopy (FTIR) studies of 1,3-butadiene hydrogenation in a batch reactor were performed to determine the catalytic activity. Step-impregnated Pt/Ni catalyst demonstrated enhanced hydrogenation activity over the parent monometallic Pt and Ni catalysts due to bimetallic bond formation. The catalyst synthesized using co-impregnation showed no enhanced activity, behaving similarly to monometallic Ni. Overall, our results indicate that reverse micelle synthesis combined with incipient wetness impregnation produced small, uniform nanoparticles with bimetallic bonds that enhanced hydrogenation activity.« less

  10. Colloidal silver-based nanogel as nonocclusive dressing for multiple superficial pellet wounds.

    PubMed

    Dharmshaktu, Ganesh Singh; Singhal, Aanshu; Pangtey, Tanuja

    2016-01-01

    A good dressing is mandatory to an uncomplicated wound healing, especially when foreign particles contaminate the wound. Various forms of dressing preparations are available for use and differ in chemical composition and efficacy. Silver has been a known agent with good antimicrobial and healing properties and recent times has seen an upsurge in various silver-based dressing supplements. We describe our report of use and efficacy of a silver nanoparticle- based gel dressing in the healing of multiple superficial firearm pellet wounds.

  11. Self adhesive dressing pouch for the protection of catheters.

    PubMed

    de la Cruz Martínez, Maria Teresa; Hernández, María José

    2002-01-01

    This paper is about a new model of dressing, used for the protection of all types of temporary and permanent catheters. Those who developed this dressing realised the practical difficulties during the placement and removal of traditional dressings, used in haemodialysis units. They also realised that it this was unpleasant for the patients, and there was a risk to the catheters when removing the dressings because of the use of scissors and other cutting instruments. This new dressing solves these previously mentioned problems and at the same time contributes to the comfort of the patients. The model has been registered as a standard using model, and therefore it is protected by law and its copyright (Intellectual Property).

  12. Tunable electromagnetically induced transparency and absorption with dressed superconducting qubits

    NASA Astrophysics Data System (ADS)

    Ian, Hou; Liu, Yu-Xi; Nori, Franco

    2010-06-01

    Electromagnetically induced transparency and absorption (EIT and EIA) are usually demonstrated using three-level atomic systems. In contrast to the usual case, we theoretically study the EIT and EIA in an equivalent three-level system: a superconducting two-level system (qubit) dressed by a single-mode cavity field. In this equivalent system, we find that both the EIT and the EIA can be tuned by controlling the level-spacing of the superconducting qubit and hence controlling the dressed system. This tunability is due to the dressed relaxation and dephasing rates which vary parametrically with the level-spacing of the original qubit and thus affect the transition properties of the dressed qubit and the susceptibility. These dressed relaxation and dephasing rates characterize the reaction of the dressed qubit to an incident probe field. Using recent experimental data on superconducting qubits (charge, phase, and flux qubits) to demonstrate our approach, we show the possibility of experimentally realizing this proposal.

  13. Impact of an absorbent silver-eluting dressing system on lower extremity revascularization wound complications.

    PubMed

    Childress, Beverly B; Berceli, Scott A; Nelson, Peter R; Lee, W Anthony; Ozaki, C Keith

    2007-09-01

    Surgical wounds for lower extremity revascularization are prone to infection and dehiscence. Acticoat Absorbent, an antimicrobial dressing, offers sustained release of ionic silver. We hypothesized that immediate application of Acticoat as a postoperative dressing would reduce wound complications in patients undergoing leg revascularization. All infrainguinal revascularization cases involving leg incisions at a single Veterans Administration Medical Center were identified from July 1, 2002, to September 30, 2005. The control group received conventional dressings, while the treatment group received an Acticoat dressing. Wound complication rates were captured via National Surgical Quality Improvement Program data. Patient characteristics and procedure distributions were similar between groups. The wound complication rate fell 64% with utilization of the Acticoat-based dressing (control 14% [17/118], treatment 5% [7/130]; P = 0.016). An Acticoat-based dressing system offers a potentially useful, cost-effective adjunct to reduce open surgical leg revascularization wound complications.

  14. Supercritical impregnation and optical characterization of loaded foldable intraocular lenses using supercritical fluids.

    PubMed

    Bouledjouidja, Abir; Masmoudi, Yasmine; Li, Yanfeng; He, Wei; Badens, Elisabeth

    2017-10-01

    To prepare drug-loaded intraocular lenses (IOLs) used to combine cataract surgery with postoperative complication treatment through supercritical impregnation while preserving their optical properties. Aix-Marseille Université, CNRS, Centrale Marseille, Laboratoire de Mécanique, Modélisation & Procédés Propres, Marseille, France, and He University Eye Hospital, Liaoning Province, China. Experimental study. Supercritical impregnations of commercial foldable IOLs used in cataract surgery with ciprofloxacin (an antibiotic) and dexamethasone 21-phosphate disodium salt (an antiinflammatory drug) were performed in a noncontinuous mode. Impregnation amounts were determined through drug-release kinetic studies. The optical characterizations of IOLs were determined by evaluating the dioptric power and the imaging quality by determining the modulating transfer function (MTF) at a specified spatial frequency according to the International Organization for Standardization (ISO 11979-2:2014). Transparent IOLs presenting an effective impregnation were obtained with a prolonged drug delivery during approximately 10 days. Optical characterizations (dioptric powers and MTF values) show preserved optical properties after supercritical treatment/impregnation. Supercritical treatments/impregnations do not damage the optical properties of IOLs and are therefore adequate for the preparation of delivery devices used for cataract surgery. Copyright © 2017. Published by Elsevier Inc.

  15. School Dress Codes v. The First Amendment: Ganging up on Student Attire.

    ERIC Educational Resources Information Center

    Jahn, Karon L.

    Do school dress codes written with the specific purpose of limiting individual dress preferences, including dress associated with gangs, infringe on speech freedoms granted by the First Amendment of the U.S. Constitution? Although the Supreme Court has extended its protection of political speech to nonverbal acts of communication, it has…

  16. Dressing of Cognitively Impaired Nursing Home Residents: Description and Analysis

    ERIC Educational Resources Information Center

    Cohen-Mansfield, Jiska; Creedon, Michael A.; Malone, Thomas; Parpura-Gill, Aleksandra; Dakheel-Ali, Maha; Heasly, Christopher

    2006-01-01

    Purpose: Getting dressed is an activity that is of particular difficulty for many persons with dementia, given the need for hand-eye coordination, fine motor skills, and overall planning skills. Despite several studies concerning interventions to improve dressing behavior, very little is known about the dressing process as it is currently…

  17. Insights on Flow Behavior of Foam in Unsaturated Porous Media during Soil Flushing.

    PubMed

    Zhao, Yong S; Su, Yan; Lian, Jing R; Wang, He F; Li, Lu L; Qin, Chuan Y

    2016-11-01

      One-dimensional column and two-dimensional tank experiments were carried out to determine (1) the physics of foam flow and propagation of foaming gas, foaming liquid, and foam; (2) the pressure distribution along foam flow and the effect of media permeability, foam flow rate and foam quality on foam injection pressure; and (3) the migration and distribution property of foam flow in homogeneous and heterogeneous sediments. The results demonstrated that: (1) gas and liquid front were formed ahead of the foam flow front, the transport speed order is foaming gas > foaming liquid > foam flowing; (2) injection pressure mainly comes from the resistance to bubble migration. Effect of media permeability on foam injection pressure mainly depends on the physics and behavior of foam flow; (3) foam has a stronger capacity of lateral spreading, besides, foam flow was uniformly distributed across the foam-occupied region, regardless of the heterogeneity of porous media.

  18. Women in relationships with cross-dressing men: a descriptive study from a nonclinical setting.

    PubMed

    Brown, G R

    1994-10-01

    Over a 6-year period, 106 women involved with men who cross-dress (mostly heterosexual transvestites) completed a questionnaire regarding themselves, their male partners, and their relationships. Interview data supplemented these questionnaires for 75% of the respondents. All respondents were recruited from nonclinical settings. The "modal" female partner was a 40-year-old Protestant, Caucasian woman, who was a firstborn child, in her first marriage. She was more likely than other women her age to be childless, and to have earned at least a 2-year college degree. She was no more likely to have had lesbian experiences or substance use problems than comparably aged American women. She had been married to her cross-dressing mate for 13 years and had known of his activities for 9 years. A quarter of women reported at least occasional sexual arousal to their mate's cross-dressing. The two variables associated with low acceptance of cross-dressing were discovery of their partner's cross-dressing after marriage and lack of sexual arousal to cross-dressing stimuli. Low acceptance was unrelated to firstborn status, amount of exposure to cross-dressing activities, or having had children. This group may be more representative of women in relationships with cross-dressing men than previous reports limited to cross-dressers and spouses who are in treatment.

  19. Umbilical Negative Pressure Dressing for Transumbilical Appendectomy in Childern.

    PubMed

    Seifarth, Federico G; Kundu, Neilendu; Guerron, Alfredo D; Garland, Mary M; Gaffley, Michaela W G; Worley, Sarah; Knight, Colin G

    2016-01-01

    Transumbilical laparoscopic-assisted appendectomy (TULAA) carries a high risk for surgical site infection. We investigated the effect of a bio-occlusive umbilical vacuum dressing on wound infection rates after TULAA for patients with acute appendicitis and compared to it with a conventional 3-port appendectomy with a nonvacuum dressing. This study was a retrospective chart review of 1377 patients (2-20 years) undergoing laparoscopic appendectomy for acute appendicitis in 2 tertiary care referral centers from January 2007 through December 2012. Twenty-two different operative technique/dressing variations were documented. The 6 technique/dressing groups with >50 patients were assessed, including a total of 1283 patients. The surgical site infection rate of the 220 patients treated with TULAA and application of an umbilical vacuum dressing with dry gauze is 1.8% (95% CI, 0.0-10.3%). This compares to an infection rate of 4.1% (95% CI, 1.3-10.5%) in 97 patients with dry dressing without vacuum. In the 395 patients who received an umbilical vacuum dressing with gauze and bacitracin, the surgical site infection rate was found to be 4.3% (95% CI, 2.7-6.8%). Application of an umbilical negative-pressure dressing with dry gauze lowers the rate of umbilical site infections in patients undergoing transumbilical laparoscopic-assisted appendectomy for acute appendicitis.

  20. Polymer-impregnated bridge slabs : performance over 10 years.

    DOT National Transportation Integrated Search

    1990-01-01

    This report presents the results of a study to evaluate the performance over a 10-year period of slabs that were impregnated to a depth of about 1 in with a monomer that was subsequently polymerized (shallow polymer impregnation). The slabs were used...

  1. FIELD STUDIES OF IMPREGNATED CONCRETE PIPE

    EPA Science Inventory

    The follow-on study (initiated in June 1980) continued to monitor performance of 1,400 ft of impregnated concrete pipe installed in several Texas cities. The performance of concrete pipe has been compared with that of sulfur-impregnated concrete pipe; hydrofluoric acid (HF)-treat...

  2. Human neutrophil elastase and collagenase sequestration with phosphorylated cotton wound dressings.

    PubMed

    Edwards, J Vincent; Howley, Phyllis S

    2007-11-01

    The design and preparation of wound dressings that redress the protease imbalance in chronic wounds is an important goal of wound healing and medical materials science. Chronic wounds contain high levels of tissue and cytokine-destroying proteases including matrix metalloprotease and neutrophil elastase. Thus, the lowering of excessive protease levels in the wound environment by wound dressing sequestration prevents the breakdown of extracellular matrix proteins and growth factors necessary for wound healing. Phosphorylated cotton wound dressings were prepared to target sequestration of proteases from chronic wound exudate through a cationic uptake binding mechanism involving salt bridge formation of the positively charged amino acid side chains of proteases with the phosphate counterions of the wound dressing fiber. Dressings were prepared by applying sodium hexametaphosphate and diammonium phosphate in separate formulations to cotton gauze by pad/dry/cure methods. Phosphorylated cotton dressings were assessed for their ability to lower elastase and collagenase activity. The phosphorylated cotton dressings lowered elastase and collagenase activity 40-80% more effectively than the untreated cotton wound dressings under conditions that mimic chronic wound exudate. Efficacy of the phosphorylated cotton was found to be related to the level of phosphorylation and a lower pH due to protonated phosphate at the surface of the dressing. The capacity of the modified gauze to sequester continued elastase secretions similar to that found in a chronic wound over a 24-h period was retained within a 80% retention of elastase sequestration and was dose-dependent. Copyright (c) 2007 Wiley Periodicals, Inc.

  3. Enhanced wound contraction in fresh wounds dressed with honey in Wistar rats (Rattus Novergicus).

    PubMed

    Osuagwu, F C; Oladejo, O W; Imosemi, I O; Aiku, A; Ekpos, O E; Salami, A A; Oyedele, O O; Akang, E U

    2004-01-01

    Due to reports that honey accelerates wound healing, an investigation on its role in wound contraction in fresh wounds inflicted on wistar rats was carried out. Twenty adult male wistar rats had 2cm by 2cm square wound inflicted on their right dorsolateral trunk. They were divided into two groups. The experimental group had their wounds dressed with honey while the control group had normal saline dressing. Wound dressing was done every five days and measurements taken at each dressing. Wound morphology was also assessed. Dressing with honey significantly enhanced percentage wound contraction on day 10 with value of 79.20+/-2.94 compared to control value of 53.50+/-4.32. p=0.0. The mean wound measurement on day 10 reduced significantly in honey group, 1.15+/-0.18 compared to control group 2.38+/-0.28. p=0.002. However, there was no significant difference in fibroblast count per high power field in honey group 68.0+/-2.59 compared to control 90.2+/-17.40, p=0.242. Honey dressing increased mean blood vessel count per high power field, 18.8+/-3.77 albeit non significantly when compared to control value of 13.4+/-2.44, p=0.264. Also honey dressing caused increased granulation tissue formation in wounds dressed with honey compared to control group. Our study suggests that honey dressing enhances wound contraction in fresh wounds which is one of the key features of wound healing.

  4. Processing parameter optimization for the laser dressing of bronze-bonded diamond wheels

    NASA Astrophysics Data System (ADS)

    Deng, H.; Chen, G. Y.; Zhou, C.; Li, S. C.; Zhang, M. J.

    2014-01-01

    In this paper, a pulsed fiber-laser dressing method for bronze-bonded diamond wheels was studied systematically and comprehensively. The mechanisms for the laser dressing of bronze-bonded diamond wheels were theoretically analyzed, and the key processing parameters that determine the results of laser dressing, including the laser power density, pulse overlap ratio, ablation track line overlap ratio, and number of scanning cycles, were proposed for the first time. Further, the effects of these four key parameters on the oxidation-damaged layer of the material surface, the material removal efficiency, the material surface roughness, and the average protrusion height of the diamond grains were explored and summarized through pulsed laser ablation experiments. Under the current experimental conditions, the ideal values of the laser power density, pulse overlap ratio, ablation track line overlap ratio, and number of scanning cycles were determined to be 4.2 × 107 W/cm2, 30%, 30%, and 16, respectively. Pulsed laser dressing experiments were conducted on bronze-bonded diamond wheels using the optimized processing parameters; next, both the normal and tangential grinding forces produced by the dressed grinding wheel were measured while grinding alumina ceramic materials. The results revealed that the normal and tangential grinding forces produced by the laser-dressed grinding wheel during grinding were smaller than those of grinding wheels dressed using the conventional mechanical method, indicating that the pulsed laser dressing technology provides irreplaceable advantages relative to the conventional mechanical dressing method.

  5. Clinical potential of a silk sericin-releasing bioactive wound dressing for the treatment of split-thickness skin graft donor sites.

    PubMed

    Siritientong, Tippawan; Angspatt, Apichai; Ratanavaraporn, Juthamas; Aramwit, Pornanong

    2014-01-01

    An ethyl alcohol-precipitated silk sericin/PVA scaffold that controlled the release of silk sericin was previously developed and applied for the treatment of full-thickness wounds in rats and demonstrated efficient healing. In this study, we aimed to further evaluate the clinical potential of this scaffold, hereafter called "silk sericin-releasing wound dressing", for the treatment of split-thickness skin graft donor sites by comparison with the clinically available wound dressing known as "Bactigras®". In vitro characterization and in vivo evaluation for safety of the wound dressings were performed. A clinical trial of the wound dressings was conducted according to standard protocols. The sericin released from the wound dressing was not toxic to HaCat human keratinocytes. A peel test indicated that the silk sericin-releasing wound dressing was less adhesive than Bactigras®, potentially reducing trauma and the risk of repeated injury upon removal. There was no evidence of skin irritation upon treatment with either wound dressing. When tested in patients with split-thickness skin graft donor sites, the wounds treated with the silk sericin-releasing wound dressing exhibited complete healing at 12 ± 5.0 days, whereas those treated with Bactigras® were completely healed at 14 ± 5.2 days (p = 1.99 × 10(-4)). In addition, treatment with the silk sericin-releasing wound dressing significantly reduced pain compared with Bactigras® particularly during the first 4 postoperative days (p = 2.70 × 10(-5) on day 1). We introduce this novel silk sericin-releasing wound dressing as an alternative treatment for split-thickness skin graft donor sites.

  6. A model for quantitative evaluation of skin damage at adhesive wound dressing removal.

    PubMed

    Matsumura, Hajime; Ahmatjan, Niyaz; Ida, Yukiko; Imai, Ryutaro; Wanatabe, Katsueki

    2013-06-01

    The removal of adhesive wound dressings from the wound surface involves a risk of damaging the intact stratum corneum and regenerating epithelium. Pain associated with the removal of wound dressings is a major issue for patients and medical personnel. Recently, wound dressings coated with a silicone adhesive have been developed to reduce such skin damage and pain on removal and they have received good evaluation in various clinical settings. However, there is neither a standard method to quantify whether or not the integrity of the stratum corneum and regenerating epithelium is retained or if both structures are damaged by the removal of wound dressings, nor are there standardised values with which to assess skin damage. We applied six different types of adhesive wound dressing on plain copy paper printed with black ink by a laser printer, removed the dressings, examined the adhesive-coated surface of the wound dressings using a high-power videoscope, and examined the stripped areas. Wound dressings coated with a silicone adhesive showed significantly less detachment of the stratum corneum and regenerating epithelium, followed by those coated with polyurethane, hydrocolloid, and acrylic adhesives. The assessment method utilised in this study revealed distinct differences between wound dressing types, but less variation in the evaluation outcome of each type. This assessment method may be useful for the evaluation of adhesive wound dressings, particularly during product development. However, further studies will be needed to examine the effectiveness of this assessment method in the clinical setting because the adherent properties of polyurethane and hydrocolloid adhesives may be altered by the absorption of water from the skin. © 2012 The Authors. International Wound Journal © 2012 John Wiley & Sons Ltd and Medicalhelplines.com Inc.

  7. Effect of different wound dressings on cell viability and proliferation.

    PubMed

    Paddle-Ledinek, Joanne E; Nasa, Zeyad; Cleland, Heather J

    2006-06-01

    Many new dressings have been developed since the early 1980s. Wound healing comprises cleansing, granulation/vascularization, and epithelialization phases. An optimum microenvironment and the absence of cytotoxic factors are essential for epithelialization. This study examines the effect of extracts of different wound dressings on keratinocyte survival and proliferation. Keratinocyte cultures were exposed for 40 hours to at least three extracts of each of the following wound dressings, which were tested in octuplicate: Acticoat, Aquacel-Ag, Aquacel, Algisite M, Avance, Comfeel Plus transparent, Contreet-H, Hydrasorb, and SeaSorb. Silicone extract provided the reference material. Controls were included of cells cultured in medium that had been incubated under conditions identical to those used with the extracts. Cell survival (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide reduction) and proliferation (5-bromo-2':-deoxyuridine incorporation) were measured. Extracts of silver-containing dressings (Acticoat, Aquacel-Ag, Contreet-H, and Avance) were most cytotoxic. Extracts of Hydrasorb were less cytotoxic but markedly affected keratinocyte proliferation and morphology. Extracts of alginate-containing dressings (Algisite M, SeaSorb, and Contreet-H) demonstrated high calcium concentrations, markedly reduced keratinocyte proliferation, and affected keratinocyte morphology. Extracts of Aquacel and Comfeel Plus transparent induced small but significant inhibition of keratinocyte proliferation. The principle of minimizing harm should be applied to the choice of wound dressing. Silver-based dressings are cytotoxic and should not be used in the absence of infection. Alginate dressings with high calcium content affect keratinocyte proliferation probably by triggering terminal differentiation of keratinocytes. Such dressings should be used with caution in cases in which keratinocyte proliferation is essential. All dressings should be tested in vitro before clinical application.

  8. Role of natural polysaccharides in radiation formation of PVA hydrogel wound dressing

    NASA Astrophysics Data System (ADS)

    Varshney, Lalit

    2007-02-01

    Radiation processed PVA-polysaccharides hydrogels have been observed to be suitable for producing transparent, flexible, mechanically strong, biocompatible, effective and economical hydrogel dressings. The dressings were formed in single stage irradiation process achieving gel formation and sterilization at 25-30 kGy gamma radiation dose. No synthetic plasticizers and additives were used. Different formulations containing poly-vinylalcohol (PVA) and polysaccharides selected from combinations of agar and carrageenan were used to make the dressings. The selected polysaccharides themselves form thermo-reversible gels and degrade on irradiation. Using concentration of polysaccharides as low as 0.5-2% resulted in increase of tensile strength from 45 g/cm 2 to 411 g/cm 2, elongation from 30% to 410% and water uptake from 25% to 157% with respect to PVA gel without polysaccharides. Besides improving mechanical strength, agar contributes more to elongation and carrageenan to mechanical strength of the gel dressing. PVA formulations containing the polysaccharides show significantly different pre-gel viscosities behaviour. Increasing the concentration of agar in the formulation to about 2% converts the sheet gel to paste gel useful for filling wound cavities. The results indicate that pre irradiation network structure of the formulation plays an important role in determining mechanical properties of the irradiated gel dressing. Formulations containing 7-9% PVA, 0.5-1.5% carrageenan and 0.5-1% agar gave highly effective usable hydrogel dressings. Scanning electron micrographs show highly porous structure of the gel. Clinical trials of wound dressing on human patients established safety and efficacy of the dressing. The dressing has been observed to be useful in treating burns, non-healing ulcers of diabetes, leprosy and other external wounds. The dressings are now being marketed in India under different brand names.

  9. A Pilot Randomized Controlled Trial of Novel Dressing and Securement Techniques in 101 Pediatric Patients.

    PubMed

    Kleidon, Tricia M; Ullman, Amanda J; Gibson, Victoria; Chaseling, Brett; Schoutrop, Jason; Mihala, Gabor; Rickard, Claire M

    2017-11-01

    To evaluate feasibility of an efficacy trial comparing peripherally inserted central catheter (PICC) dressing and securement techniques to prevent complications and failure. This pilot, 3-armed, randomized controlled trial was undertaken at Royal Children's Hospital and Lady Cilento Children's Hospital, Brisbane, Australia, between April 2014 and September 2015. Pediatric participants (N = 101; age range, 0-18 y) were assigned to standard care (bordered polyurethane [BPU] dressing, sutureless securement device), tissue adhesive (TA) (plus BPU dressing), or integrated securement dressings (ISDs). Average PICC dwell time was 8.1 days (range, 0.2-27.7 d). Primary outcome was trial feasibility including PICC failure. Secondary outcomes were PICC complications, dressing performance, and parent and staff satisfaction. Protocol feasibility was established. PICC failure was 6% (2/32) with standard care, 6% (2/31) with ISD, and 3% (1/32) with TA. PICC complications were 16% across all groups. TA provided immediate postoperative hemostasis, prolonging the first dressing change until 5.5 days compared with 3.5 days and 2.5 days with standard care and ISD respectively. Bleeding was the most common reason for first dressing change: standard care (n = 18; 75%), ISD (n = 11; 69%), TA (n = 4; 27%). Parental satisfaction (median 9.7/10; P = .006) and staff feedback (9.2/10; P = .002) were most positive for ISD. This research suggests safety and acceptability of different securement dressings compared with standard care; securement dressings may also reduce dressing changes after insertion. Further research is required to confirm clinically cost-effective methods to prevent PICC failure. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  10. Comparison of three different dressings for partial thickness burns in children: study protocol for a randomised controlled trial

    PubMed Central

    2013-01-01

    Background In the paediatric population, pain and distress associated with burn injuries during wound care procedures remain a constant challenge. Although silver dressings are the gold standard for burn care in Australasia, very few high-level trials have been conducted that compare silver dressings to determine which will provide the best level of care clinically. Therefore, for paediatric patients in particular, identifying silver dressings that are associated with lower levels of pain and rapid wound re-epithelialisation is imperative. This study will determine whether there is a difference in time to re-epithelialisation and pain and distress experienced during wound care procedures among Acticoat™, Acticoat™ combined with Mepitel™ and Mepilex Ag™ dressings for acute, paediatric partial thickness burns. Methods/Design Children aged 0 to 15 years with an acute partial thickness (superficial partial to deep partial thickness inclusive) burn injury and a burn total body surface area of ≤10% will be eligible for the trial. Patients will be randomised to one of the three dressing groups: (1) Acticoat™ or (2) Acticoat™ combined with Mepitel™ or (3) Mepilex Ag™. A minimum of 28 participants will be recruited for each treatment group. Primary measures of pain, distress and healing will be repeated at each dressing change until complete wound re-epithelialisation occurs or skin grafting is required. Additional data collected will include infection status at each dressing change, physical function, scar outcome and scar management requirements, cost effectiveness of each dressing and staff perspectives of the dressings. Discussion The results of this study will determine the effects of three commonly used silver and silicone burn dressing combinations on the rate of wound re-epithelialisation and pain experienced during dressing procedures in acute, paediatric partial thickness burn injuries. Trial registration Australian New Zealand Clinical Trials Registry ACTRN12613000105741 PMID:24274190

  11. Improving Cull Cow Meat Quality Using Vacuum Impregnation.

    PubMed

    Leal-Ramos, Martha Y; Alarcón-Rojo, Alma D; Gutiérrez-Méndez, Néstor; Mújica-Paz, Hugo; Rodríguez-Almeida, Felipe; Quintero-Ramos, Armando

    2018-05-07

    Boneless strip loins from mature cows (50 to 70 months of age) were vacuum impregnated (VI) with an isotonic solution (IS) of sodium chloride. This study sought to determine the vacuum impregnation and microstructural properties of meat from cull cows. The experiments were conducted by varying the pressure, p 1 (20.3, 71.1 kPa), and time, t 1 (0.5, 2.0, 4.0 h), of impregnation. After the VI step, the meat was kept for a time, t 2 (0.0, 0.5, 2.0, 4.0 h), in the IS under atmospheric pressure. The microstructural changes, impregnation, deformation, and porosity of the meat were measured in all the treatments. Impregnation and deformation levels in terms of volume fractions of the initial sample at the end of the vacuum step and the VI processes were calculated according to the mathematical model for deformation-relaxation and hydrodynamic mechanisms. Scanning electron microscopy (SEM) was used to study the microstructure of the vacuum-impregnated meat samples. Results showed that both the vacuum and atmospheric pressures generated a positive impregnation and deformation. The highest values of impregnation X (10.5%) and deformation γ (9.3%) were obtained at p 1 of 71.1 kPa and t 1 of 4.0 h. The sample effective porosity ( ε e ) exhibited a significant interaction ( p < 0.01) between p 1 × t 1 . The highest ε e (14.0%) was achieved at p 1 of 20.3 kPa and t 1 of 4.0 h, whereas the most extended distension of meat fibers (98 μm) was observed at the highest levels of p ₁, t ₁, and t ₂. These results indicate that meat from mature cows can undergo a vacuum-wetting process successfully, with an IS of sodium chloride to improve its quality.

  12. Process of Making Boron-Fiber Reinforced Composite Tape

    NASA Technical Reports Server (NTRS)

    Belvin, Harry L. (Inventor); Cano, Roberto J. (Inventor); Johnston, Norman J. (Inventor); Marchello, Joseph M. (Inventor)

    2002-01-01

    The invention is an apparatus and method for producing a hybrid boron reinforced polymer matrix composition from powder pre-impregnated fiber tow bundles and a linear array of boron fibers. The boron fibers are applied onto the powder pre-impregnated fiber tow bundles and then are processed within a processing component having an impregnation bar assembly. After passing through variable-dimension forming nip-rollers, the powder pre-impregnated fiber tow bundles with the boron fibers become a hybrid boron reinforced polymer matrix composite tape. A driving mechanism pulls the powder pre-impregnated fiber tow bundles with boron fibers through the processing line of the apparatus and a take-up spool collects the formed hybrid boron-fiber reinforced polymer matrix composite tape.

  13. Vacuum powder injector and method of impregnating fiber with powder

    NASA Astrophysics Data System (ADS)

    Working, Dennis C.

    1993-05-01

    A method and apparatus uniformly impregnate stranded material with dry powder such as low solubility, high melt flow polymer powder to produce, for example, composite prepregs. The stranded material is expanded in an impregnation chamber by an influx of air so that the powder, which may enter through the same inlet as the air, penetrates to the center of the stranded material. The stranded material then is contracted for holding the powder therein. The stranded material and powder may be pulled through the impregnation chamber in the same direction by vacuum. Larger particles of powder which do not fully penetrate the stranded material may be combed into the stranded material and powder which does not impregnate the stranded material may be collected and reused.

  14. Vacuum powder injector and method of impregnating fiber with powder

    NASA Technical Reports Server (NTRS)

    Working, Dennis C. (Inventor)

    1993-01-01

    A method and apparatus uniformly impregnate stranded material with dry powder such as low solubility, high melt flow polymer powder to produce, for example, composite prepregs. The stranded material is expanded in an impregnation chamber by an influx of air so that the powder, which may enter through the same inlet as the air, penetrates to the center of the stranded material. The stranded material then is contracted for holding the powder therein. The stranded material and powder may be pulled through the impregnation chamber in the same direction by vacuum. Larger particles of powder which do not fully penetrate the stranded material may be combed into the stranded material and powder which does not impregnate the stranded material may be collected and reused.

  15. Antibiotics and antiseptics for pressure ulcers.

    PubMed

    Norman, Gill; Dumville, Jo C; Moore, Zena E H; Tanner, Judith; Christie, Janice; Goto, Saori

    2016-04-04

    Pressure ulcers, also known as bedsores, decubitus ulcers and pressure injuries, are localised areas of injury to the skin or the underlying tissue, or both. A range of treatments with antimicrobial properties, including impregnated dressings, are widely used in the treatment of pressure ulcers. A clear and current overview is required to facilitate decision making regarding use of antiseptic or antibiotic therapies in the treatment of pressure ulcers. This review is one of a suite of Cochrane reviews investigating the use of antiseptics and antibiotics in different types of wounds. It also forms part of a suite of reviews investigating the use of different types of dressings and topical treatments in the treatment of pressure ulcers. To assess the effects of systemic and topical antibiotics, and topical antiseptics on the healing of infected and uninfected pressure ulcers being treated in any clinical setting. In October 2015 we searched: the Cochrane Wounds Specialised Register, the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library), Ovid MEDLINE, Ovid MEDLINE (In-Process & Other Non-Indexed Citations), Ovid EMBASE, and EBSCO CINAHL Plus. We also searched three clinical trials registries and the references of included studies and relevant systematic reviews. There were no restrictions based on language or date of publication or study setting. Randomised controlled trials which enrolled adults with pressure ulcers of stage II or above were included in the review. Two review authors independently performed study selection, risk of bias assessment and data extraction. We included 12 trials (576 participants); 11 had two arms and one had three arms. All assessed topical agents, none looked at systemic antibiotics. The included trials assessed the following antimicrobial agents: povidone iodine, cadexomer iodine, gentian violet, lysozyme, silver dressings, honey, pine resin, polyhexanide, silver sulfadiazine, and nitrofurazone with ethoxy-diaminoacridine. Comparators included a range of other dressings and ointments without antimicrobial properties and alternative antimicrobials. Each comparison had only one trial, participant numbers were low and follow-up times short. The evidence varied from moderate to very low quality.Six trials reported the primary outcome of wound healing. All except one compared an antiseptic with a non-antimicrobial comparator. There was some moderate and low quality evidence that fewer ulcers may heal in the short term when treated with povidone iodine compared with non-antimicrobial alternatives (protease-modulating dressings (risk ratio (RR) 0.78, 95% confidence interval (CI) 0.62 to 0.98) and hydrogel (RR 0.64, 95% CI 0.43 to 0.97)); and no clear difference between povidone iodine and a third non-antimicrobial treatment (hydrocolloid) (low quality evidence). Pine resin salve may heal more pressure ulcers than hydrocolloid (RR 2.83, 95% CI 1.14 to 7.05) (low quality evidence). There is no clear difference between cadexomer iodine and standard care, and between honey a combined antiseptic and antibiotic treatment (very low quality evidence).Six trials reported adverse events (primary safety outcome). Four reported no adverse events; there was very low quality evidence from one showing no clear evidence of a difference between cadexomer iodine and standard care; in one trial it was not clear whether data were appropriately reported.There was limited reporting of secondary outcomes. The five trials that reported change in wound size as a continuous outcome did not report any clear evidence favouring any particular antiseptic/anti-microbial treatments. For bacterial resistance, one trial found some evidence of more MRSA eradication in participants with ulcer treated with a polyhexanide dressing compared with a polyhexanide swab (RR 1.48, 95% CI 1.02 to 2.13); patients in the dressing group also reported less pain (MD -2.03, 95% CI -2.66 to -1.40). There was no clear evidence of a difference between interventions in infection resolution in three other comparisons. Evidence for secondary outcomes varied from moderate to very low quality; where no GRADE assessment was possible we identified substantial limitations which an assessment would have taken into account. The relative effects of systemic and topical antimicrobial treatments on pressure ulcers are not clear. Where differences in wound healing were found, these sometimes favoured the comparator treatment without antimicrobial properties. The trials are small, clinically heterogenous, generally of short duration, and at high or unclear risk of bias. The quality of the evidence ranges from moderate to very low; evidence on all comparisons was subject to some limitations.

  16. 21 CFR 529.1003 - Flurogestone acetate-impregnated vaginal sponge.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Flurogestone acetate-impregnated vaginal sponge... § 529.1003 Flurogestone acetate-impregnated vaginal sponge. (a) Specifications. Each vaginal sponge... ewes during their normal breeding season. (2) Limitations. Using applicator provided, insert sponge...

  17. A study of ignition of metal impregnated carbons: the influence of oxygen content in the activated carbon matrix.

    PubMed

    van der Merwe, M M; Bandosz, T J

    2005-02-01

    A study of the reason for the early ignition of coconut-based impregnated carbon in comparison with the peat-based impregnated carbon was conducted. The surface features of carbons were evaluated using various physicochemical methods. The metal analysis of the initial carbon indicated that the content of potassium was higher in the coconut-based carbon. The surface functional group analysis revealed the presence of similar surface species; however, the peat-based carbon was more acidic in its chemical nature. Since the oxygen content was higher in the peat-based carbon, the early ignition of the coconut-based material was attributed to its higher affinity to chemisorb oxygen, which leads to exothermic effects. This conclusion was confirmed by performing oxidation of coconut-based carbon prior to impregnation. This process increased the ignition temperature for Cu/Cr impregnated coconut-based material from 186 to 289 degrees C and for the Cu/Zn/Mo impregnated carbon from 235 to 324 degrees C.

  18. Continuous fiber thermoplastic prepreg

    NASA Technical Reports Server (NTRS)

    Wilson, Maywood L. (Inventor); Johnson, Gary S. (Inventor)

    1993-01-01

    A pultrusion machine employing a corrugated impregnator vessel to immerse multiple, continuous strand, fiber tow in an impregnating material, and an adjustable metered exit orifice for the impregnator vessel to control the quantity of impregnating material retained by the impregnated fibers, is provided. An adjustable height insert retains transverse rod elements within each depression of the corrugated vessel to maintain the individual fiber tows spread and in contact with the vessel bottom. A series of elongated heating dies, transversely disposed on the pultrusion machine and having flat heating surfaces with radiused edges, ensure adequate temperature exposed dwell time and exert adequate pressure on the impregnated fiber tows, to provide the desired thickness and fiber/resin ratio in the prepreg formed. The prepreg passing through the pulling mechanism is wound on a suitable take-up spool for subsequent use. A formula is derived for determining the cross sectional area opening of the metering device. A modification in the heating die system employs a heated nip roller in lieu of one of the pressure applying flat dies.

  19. Impregnation of cinnamaldehyde into cassava starch biocomposite films using supercritical fluid technology for the development of food active packaging.

    PubMed

    de Souza, Ana Cristina; Dias, Ana M A; Sousa, Hermínio C; Tadini, Carmen C

    2014-02-15

    In this work, supercritical solvent impregnation (SSI) has been tested for the incorporation of natural compounds into biocomposite materials for food packaging. Cinnamaldehyde, with proved antimicrobial activity against fungi commonly found in bread products, was successfully impregnated on biocomposite cassava starch based materials using supercritical carbon dioxide as solvent. Different process experimental conditions were tested (pressure, impregnation time and depressurization rate) at a fixed temperature (35 °C) in order to study their influence on the amount of impregnated cinnamaldehyde as well as on the morphology of the films. Results showed that all conditions permitted to impregnate antimicrobial active amounts superior to those previously obtained using conventional incorporation methods. Moreover, a significant decrease of the equilibrium water vapor sorption capacity and water vapor permeability of the films was observed after SSI processing which is a clear advantage of the process, considering the envisaged applications. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Calibration of two passive air samplers for monitoring phthalates and brominated flame-retardants in indoor air.

    PubMed

    Saini, Amandeep; Okeme, Joseph O; Goosey, Emma; Diamond, Miriam L

    2015-10-01

    Two passive air samplers (PAS), polyurethane foam (PUF) disks and Sorbent Impregnated PUF (SIP) disks, were characterized for uptake of phthalates and brominated flame-retardants (BFRs) indoors using fully and partially sheltered housings. Based on calibration against an active low-volume air sampler for gas- and particle-phase compounds, we recommend generic sampling rates of 3.5±0.9 and 1.0±0.4 m(3)/day for partially and fully sheltered housing, respectively, which applies to gas-phase phthalates and BFRs as well as particle-phase DEHP (the later for the partially sheltered PAS). For phthalates, partially sheltered SIPs are recommended. Further, we recommend the use of partially sheltered PAS indoors and a deployment period of one month. The sampling rate for the partially sheltered PUF and SIP of 3.5±0.9 m(3)/day is indistinguishable from that reported for fully sheltered PAS deployed outdoors, indicating the role of the housing outdoors to minimize the effect of variable wind velocities on chemical uptake, versus the partially sheltered PAS deployed indoors to maximize chemical uptake where air flow rates are low. Copyright © 2015. Published by Elsevier Ltd.

  1. Significant solubility of carbon dioxide in Soluplus® facilitates impregnation of ibuprofen using supercritical fluid technology.

    PubMed

    Obaidat, Rana; Alnaief, Mohammed; Jaeger, Philip

    2017-04-13

    Treatment of Soluplus ® with supercritical carbon dioxide allows promising applications in preparing dispersions of amorphous solids. Several characterization techniques were employed to reveal this effect, including CO 2 gas sorption under high pressure and physicochemical characterizations techniques. A gravimetric method was used to determine the solubility of carbon dioxide in the polymer at elevated pressure. The following physicochemical characterizations were used: thermal analysis, X-ray diffraction, Fourier transform, infrared spectroscopy and scanning electron microscopy. Drug loading of the polymer with ibuprofen as a model drug was also investigated. The proposed treatment with supercritical carbon dioxide allows to prepare solid solutions of Soluplus ® in less than two hours at temperatures that do not exceed 45 °C, which is a great advantage to be used for thermolabile drugs. The advantages of using this technology for Soluplus ® formulations lies behind the high sorption capability of carbon dioxide inside the polymer. This will ensure rapid diffusion of the dissolved/dispersed drug inside the polymer under process conditions and rapid precipitation of the drug in the amorphous form during depressurization accompanied by foaming of the polymer.

  2. Ultrafast synthesis of Te nanorods as cathode materials for lithium-tellurium batteries

    NASA Astrophysics Data System (ADS)

    Huang, Dekang; Li, Shu; Xiao, Xin; Cao, Minglei; Gao, Lin; Xiang, Yong-Gang; Chen, Hao; Shen, Yan

    2017-12-01

    Recently, tellurium has been regarded as a promising cathode material for rechargeable lithium-ion batteries due to its high theoretical volumetric capacity. However, a plethora of research are focusing on impregnating the tellurium into porous carbon materials by the thermal-diffusion method, which would consume large amounts of energy and take prolonged time. Herein, a carbon and binder-free cathode with 100% Te is fabricated by a facile galvanic replacement method on a nickle foam. Driven by the large electrochemical potential difference between Ni and Te, desirable amounts of Te can be obtained in just 10 min with no need of energy input. Li-Te batteries constructed by the as-obtained cathode show relatively good performance in DMSO solvent. To further elevate the performance of this battery especially at low current density, commercial carbon cloth is added between the separator and Te electrode as an interlayer. The cell with interlayer delivers a gravimetric capacity of 116.2 mAh g-1 after 70 cycles at the current density of 100 mA g-1, which is 2.8 times as high as that of a cell without interlayer (40.4 mAh g-1).

  3. Enhancing in situ hydrogen peroxide generation of greige cotton nonwoven wound dressings via ascorbate stabilized copper micro- and nano-particles

    USDA-ARS?s Scientific Manuscript database

    Understanding how wound dressings may be designed to address critical unsolved issues in wound repair and treatment influences the development of dressings and new concepts of promoting healing. The vast majority of commercial dressing materials focus on the physical aspects of wounds, e.g., acting ...

  4. School Dress Codes and Uniform Policies.

    ERIC Educational Resources Information Center

    Anderson, Wendell

    2002-01-01

    Opinions abound on what students should wear to class. Some see student dress as a safety issue; others see it as a student-rights issue. The issue of dress codes and uniform policies has been tackled in the classroom, the boardroom, and the courtroom. This Policy Report examines the whole fabric of the debate on dress codes and uniform policies…

  5. Multi-dressing suppression and enhancement and all-optical switching in parametrically amplified four-wave mixing

    NASA Astrophysics Data System (ADS)

    Li, Xinghua; Zhang, Dan; Sun, Ming; Li, Kangkang; Wang, Zhiguo; Zhang, Yanpeng

    2018-04-01

    We study different dressing effects in parametrically amplified four-wave mixing (PA-FWM) processes. By seeding a weak probe laser into the Stokes or anti-Stokes channel of the FWM, the gain process is generated in the so-called bright twin beams which are the probe and conjugate beams. The dressing types dramatically affect the gain factors in both the probe and conjugate channels. The gain factor of the FWM signal decreases under the cascade-type dressing and the signal's shape splits into two dips under this dressing type. However, the intensity of the FWM signal changes from suppression to enhancement under the parallel-type dressing. We will apply this switching process to all-optical switching.

  6. Overview of Silk Fibroin Use in Wound Dressings.

    PubMed

    Farokhi, Mehdi; Mottaghitalab, Fatemeh; Fatahi, Yousef; Khademhosseini, Ali; Kaplan, David L

    2018-05-12

    Recently, biomimetic wound dressings were introduced as potential replacements for treating skin injuries. Although there are some clinically available skin replacements, the range of wound types and locations necessitates a broader range of options for the clinic. Natural polymeric-based dressings are of central interest in this area due to their outstanding biocompatibility, biodegradability, low toxicity, and non-allergenic nature. Among them, silk fibroin (SF) has exceptional characteristics as a wound dressing. SF-based dressings can also be used as carriers for delivering drugs, growth factors, and bioactive agents to the wound area, while providing appropriate support for complete healing. In this review, we describe recent advances in the development of SF-based wound dressings for skin regeneration. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Ca and Fe modified biochars as adsorbents of arsenic and chromium in aqueous solutions.

    PubMed

    Agrafioti, Evita; Kalderis, Dimitrios; Diamadopoulos, Evan

    2014-12-15

    This work investigated the production of Ca and Fe modified biochars in order to use them for the removal of arsenic As(V) and chromium Cr(VI) from aqueous solutions. Rice husk was impregnated with CaO at an impregnation ratio 0.114, while both rice husk and the organic fraction of municipal solid wastes were impregnated with Fe(0) and Fe(3+) at impregnation ratios 0.114 and 0.23. The modified biochars exhibited high As(V) removal capacity (>95%), except for the case of rice husk impregnated with Fe(0), whose removal capacity reached only 58%. All modified biochars exhibited much better As(V) removal capacity compared to the non-impregnated biochars. However, the Cr(VI) removal rates were not as high as the As(V) ones. The maximum Cr(VI) removal was observed in the case of rice husk biochar impregnated with 2.3% w/w Fe(3+), whereas the majority of impregnation agents examined did not manage to enhance the biochars' Cr(VI) removal ability. The equilibrium study showed that the Freundlich model can adequately describe the sorption process for the majority of samples examined. Analysis of the amount of Fe present in the equilibrium solutions suggested that the main mechanisms of As(V) and Cr(VI) removal were possibly metal precipitation and electrostatic interactions between the modified biochars and the adsorbate. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Laser-acoustic transcutaneous drug delivery: A new trend in administration of drugs

    NASA Astrophysics Data System (ADS)

    Zharov, Vladimir P.; Latyshev, Alexei S.

    1999-03-01

    This work deals with the principles of transcutaneous drug delivery technique which uses optoacoustic (OA) effect. Laser OA impregnation, enhanced laser OA impregnation, simple laser and laser OA injections are presented. Drug impregnation mathematical model and preliminary experiments on laser injection are described.

  9. A retrospective review of burn dressings on a porcine burn model.

    PubMed

    Wang, Xue-Qing; Kravchuk, Olena; Kimble, Roy M

    2010-08-01

    This is a study to compare wound healing among three types of dressings on a porcine model with deep-dermal-partial-thickness burns. The burns in this study were from eight animal trials conducted in the past for other purposes and only burns with a uniform pale appearance that had served as controls in original experiments were selected. In total, there were 57 burns in 33 pigs, using one of following three dressings: Acticoat (Silver) (3 trials), Jelonet (Gauze) (3 trials), and Solosite Gel/Jelonet (Gel/Gauze) (2 trials). The wound healing assessments included wound re-epithelialisation during a 6-week period, clinical and histological scar assessments at week 6 after burn. Of all wound healing/scar assessments, only re-epithelialisation showed statistical difference between dressings. Earlier re-epithelialisation was observed in Gel/Gauze dressings compared to Silver and/or Gauze dressings. However, this study revealed huge variation in wound healing outcome between 3 trials within both Silver and/or Gauze dressings, supported by significant differences on re-epithelialisation, clinical and histological scar measurements. In addition, it was found that larger animals healed better than smaller ones, based on weights from 21 pigs. Of all dressings, Silver delivers the best protection for wound colonization/infection. Wound colonization/infection was found to confine wound healing and lead to thinner RND in scars. From this study, we cannot find enough evidence to suggest the beneficial effect of one dressing(s) over others on burn wound healing outcome on a porcine model with small deep-dermal-partial-thickness burns with a relative small sample size.

  10. Effect of virtual reality distraction on pain among patients with hand injury undergoing dressing change.

    PubMed

    Guo, Chunlan; Deng, Hongyan; Yang, Jian

    2015-01-01

    To assess the effect of virtual reality distraction on pain among patients with a hand injury undergoing a dressing change. Virtual reality distraction can effectively alleviate pain among patients undergoing a dressing change. Clinical research has not addressed pain control during a dressing change. A randomised controlled trial was performed. In the first dressing change sequence, 98 patients were randomly divided into an experimental group and a control group, with 49 cases in each group. Pain levels were compared between the two groups before and after the dressing change using a visual analog scale. The sense of involvement in virtual environments was measured using the Pearson correlation coefficient analysis, which determined the relationship between the sense of involvement and pain level. The difference in visual analog scale scores between the two groups before the dressing change was not statistically significant (t = 0·196, p > 0·05), but the scores became statistically significant after the dressing change (t = -30·792, p < 0·01). The correlation between the sense of involvement in a virtual environment and pain level during the dressing was statistically significant (R(2) = 0·5538, p < 0·05). Virtual reality distraction can effectively alleviate pain among patients with a hand injury undergoing a dressing change. Better results can be obtained by increasing the sense of involvement in a virtual environment. Virtual reality distraction can effectively relieve pain without side effects and is not reliant on a doctor's prescription. This tool is convenient for nurses to use, especially when analgesics are unavailable. © 2014 John Wiley & Sons Ltd.

  11. In vitro microbial inhibition and cellular response to novel biodegradable composite wound dressings with controlled release of antibiotics.

    PubMed

    Elsner, J J; Berdicevsky, I; Zilberman, M

    2011-01-01

    About 70% of all people with severe burns die from related infections, despite advances in treatment regimens and the best efforts of nurses and doctors. Although silver-eluting wound dressings are available for addressing this problem, there is growing evidence of the deleterious effects of such dressings in delaying the healing process owing to cellular toxicity. A new concept of antibiotic-eluting composite wound dressings is described here. These dressings are based on a polyglyconate mesh coated with a porous poly-(dl-lactic-co-glycolic acid) matrix loaded with antibiotic drugs. The effect of antibiotic release on bacterial inhibition was studied, and cell cytotoxicity was examined. The dressings resulted in a 99.99% decrease in the viable counts of Pseudomonas aeruginosa and Staphylococcus albus at very high initial inoculations of 10⁷-10⁸ CFU ml⁻¹ after only 1 day, while such a decrease in Staphylococcus aureus was obtained within 3 days. Bacterial inhibition zones around the dressing material were found to persist for 2 weeks, indicating a long-lasting antimicrobial effect. Despite severe toxicity to bacteria, the dressing material was found to have no toxic effect on cultured fibroblasts, indicating that the new antibiotic-eluting wound dressings represent an effective option for selective treatment of bacterial infections. Copyright © 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  12. IMPREGNATION OF CONCRETE PIPE FOR CORROSION RESISTANCE AND STRENGTH IMPROVEMENT

    EPA Science Inventory

    The program was undertaken to field test concrete sewer pipe that had been impregnated with sulfur or hydrofluoric acid. This program was a follow-on to a previous laboratory study sponsored by EPA entitled, Impregnation of Concrete Pipe, 11024EQE 06/71. In a subsequent grant ext...

  13. IN-FLIGHT CAPTURE OF ELEMENTAL MERCURY BY A CHLORINE-IMPREGNATED ACTIVATED CARBON

    EPA Science Inventory

    The paper discusses the in-flight capture of elemental mercury (Hgo) by a chlorine (C1)-impregnated activated carbon. Efforts to develop sorbents for the control of Hg emissions have demonstrated that C1-impregnation of virgin activated carbons using dilute solutions of hydrogen ...

  14. Kl-impregnated Oyster Shells as a Solid Catalyst for Soybean Oil Transesterificaton

    USDA-ARS?s Scientific Manuscript database

    Research on inexpensive and green catalysts is needed for economical production of biodiesel. The goal of the research was to test KI-impregnated oyster shell as a solid catalyst for transesterification of soybean oil. Specific objectives were to characterize KI-impregnated oyster shell, determine t...

  15. A Comparative Study of Raw and Metal Oxide Impregnated Carbon Nanotubes for the Adsorption of Hexavalent Chromium from Aqueous Solution

    PubMed Central

    Qureshi, Muhammad I.; Al-Baghli, Nadhir

    2017-01-01

    The present study reports the use of raw, iron oxide, and aluminum oxide impregnated carbon nanotubes (CNTs) for the adsorption of hexavalent chromium (Cr(VI)) ions from aqueous solution. The raw CNTs were impregnated with 1% and 10% loadings (weight %) of iron oxide and aluminum oxide nanoparticles using wet impregnation technique. The synthesized materials were characterized using scanning electron microscopy (SEM) and thermogravimetric analysis (TGA). Batch adsorption experiments were performed to assess the removal efficiency of Cr(VI) ions from water and the effects of pH, contact time, adsorbent dosage, and initial concentration of the Cr(VI) ions were investigated. Results of the study revealed that impregnated CNTs achieved significant increase in the removal efficiency of Cr(VI) ions compared to raw CNTs. In fact, both CNTs impregnated with 10% loading of iron and aluminum oxides were able to remove up to 100% of Cr(VI) ions from aqueous solution. Isotherm studies were carried out using Langmuir and Freundlich isotherm models. Adsorption kinetics of Cr(VI) ions from water was found to be well described by the pseudo-second-order model. The results suggest that metallic oxide impregnated CNTs have very good potential application in the removal of Cr(VI) ions from water resulting in better environmental protection. PMID:28487625

  16. Carbonization of heavy metal impregnated sewage sludge oriented towards potential co-disposal.

    PubMed

    Dou, Xiaomin; Chen, Dezhen; Hu, Yuyan; Feng, Yuheng; Dai, Xiaohu

    2017-01-05

    Sewage sludge (SS) is adopted as a stabilizer to immobilize externally impregnated heavy metals through carbonization oriented towards the co-disposal of SS and some hazardous wastes. Firstly Cu and Pb were impregnated into SS to ascertain the impregnating capacity and leaching behaviours of heavy metals in the resulting sewage sludge char (SSC). Meanwhile, scanning electron microscopy (SEM) and X-ray diffraction (XRD) were employed to detect the heavy metal phase in the SSC. The results showed that within 400-800°C and an impregnating concentration ≨0.5wt%, more than 90% of the externally impregnated Cu and Pb were remained in the SSC and immobilized. And higher temperatures helped produce non-hazardous SSC. In addition, SEM and XRD analyses revealed that externally impregnated heavy metals could be converted into stable forms and evenly distributed throughout the SSC. In the second step municipal solid waste incineration fly ash (FA) was kneaded into SS and subjected to carbonization; it has been proved that the heavy metals in FA can be well immobilized in the resulting char when FA: SS mass ratio is 1:5. Those results show that sewage sludge can be co-carbonized with wastes contaminated with heavy metals to achieve co-disposal. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. A new postoperative otoplasty dressing technique using cyanoacrylate tissue adhesives.

    PubMed

    Vetter, Miriam; Foehn, Matthias; Wedler, Volker

    2010-04-01

    There are many techniques for cosmetic surgery of the ears and also many different procedures for postoperative treatment. The postoperative dressing is described as important for a successful outcome. We present our method of postoperative dressing in the form of liquid bonding. Cyanoacrylate tissue adhesives as liquid bonding agents are used for fixation of the pinna at the mastoid area. After 10-14 days the bonding can be easily removed. No huge dressings, tapes, or plasters are necessary. The patients are satisfied with the light dressing; they do not feel ashamed to appear in public. We have found this dressing technique to be simple and economical, especially because of the use of the bonding for skin closure before. It can be used after otoplasty with an anterior or a posterior approach.

  18. Current applications of foams formed from mixed surfactant-polymer solutions.

    PubMed

    Bureiko, Andrei; Trybala, Anna; Kovalchuk, Nina; Starov, Victor

    2015-08-01

    Foams cannot be generated without the use of special foaming agents, as pure liquids do not foam. The most common foaming agents are surfactants, however often for foam stability one active agent is not enough, it is necessary to add other component to increase foam lifetime. Foams on everyday use are mostly made from mixture of different components. Properly chosen combinations of two active ingredients lead to a faster foam formation and increased foam stability. During the last decade polymers (mainly polyelectrolytes and proteins) have become frequently used additives to foaming solutions. Mixtures of surfactants and polymers often demonstrate different foaming properties in comparison to surfactant only or polymer only solutions. The nature of surfactant-polymer interactions is complicated and prediction of resulting foaming properties of such formulations is not straightforward. Properties and foaming of surfactant-polymer mixtures are discussed as well as current applications of foams and foaming agents as foams are widely used in cosmetics, pharmaceutics, medicine and the food industry. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Structure design of and experimental research on a two-stage laval foam breaker for foam fluid recycling.

    PubMed

    Wang, Jin-song; Cao, Pin-lu; Yin, Kun

    2015-07-01

    Environmental, economical and efficient antifoaming technology is the basis for achievement of foam drilling fluid recycling. The present study designed a novel two-stage laval mechanical foam breaker that primarily uses vacuum generated by Coanda effect and Laval principle to break foam. Numerical simulation results showed that the value and distribution of negative pressure of two-stage laval foam breaker were larger than that of the normal foam breaker. Experimental results showed that foam-breaking efficiency of two-stage laval foam breaker was higher than that of normal foam breaker, when gas-to-liquid ratio and liquid flow rate changed. The foam-breaking efficiency of normal foam breaker decreased rapidly with increasing foam stability, whereas the two-stage laval foam breaker remained unchanged. Foam base fluid would be recycled using two-stage laval foam breaker, which would reduce the foam drilling cost sharply and waste disposals that adverse by affect the environment.

  20. Dressed Wilson loops as dual condensates in response to magnetic and electric fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bruckmann, Falk; Endroedi, Gergely

    2011-10-01

    We introduce dressed Wilson loops as a novel confinement observable. It consists of closed planar loops of arbitrary geometry but fixed area, and its expectation values decay with the latter. The construction of dressed Wilson loops is based on chiral condensates in response to magnetic and electric fields, thus linking different physical concepts. We present results for generalized condensates and dressed Wilson loops on dynamical lattice configurations and confirm the agreement with conventional Wilson loops in the limit of large probe mass. We comment on the renormalization of dressed Wilson loops.

  1. The role of dressings in the prevention of pressure ulcers.

    PubMed

    Brown, Julie

    2016-08-11

    Pressure ulceration is a significant global healthcare problem and represents a considerable burden on healthcare resources. Within the literature an increasing number of studies have examined the role prophylactic dressings play in redistributing pressure and helping to protect the skin from the effects of friction and shear. The use of dressings to prevent pressure ulcers may be considered a controversial issue, as previous opinion has been that dressings do not reduce the effects of pressure. This article will critically evaluate the literature to examine the role dressings play in the prevention of pressure ulceration.

  2. Face Masks for Noninvasive Ventilation: Fit, Excess Skin Hydration, and Pressure Ulcers.

    PubMed

    Visscher, Marty O; White, Cynthia C; Jones, Jennifer M; Cahill, Thomas; Jones, Donna C; Pan, Brian S

    2015-11-01

    Pressure ulcers (stages III and IV) are serious safety events (ie, never events). Healthcare institutions are no longer reimbursed for costs to care for affected patients. Medical devices are the leading cause of pediatric pressure ulcers. Face masks for noninvasive ventilation were associated with a high percentage of pressure ulcers at our institution. A prospective cohort study investigated factors contributing to pressure ulcer development in 50 subjects using face masks for noninvasive ventilation. Color imaging, 3-dimensional surface imaging, and skin hydration measurements were used to identify early skin compromise and evaluate 3 interventions to reduce trauma: (1) a silicone foam dressing, (2) a water/polyethylene oxide hydrogel dressing, and (3) a flexible cloth mask. A novel mask fit technique was used to examine the impact of fit on the potential for skin compromise. Fifty subjects age 10.4 ± 9.1 y participated with color images for 22, hydration for 34, and mask fit analysis for 16. Of these, 69% had diagnoses associated with craniofacial anomalies. Stage I pressure ulcers were the most common injury. Skin hydration difference was 317 ± 29 for sites with erythema versus 75 ± 28 for sites without erythema (P < .05) and smallest for the cloth mask (P < .05). Fit distance metrics differed for the nasal, oronasal, and face shield interfaces, with threshold distances being higher for the oronasal mask than the others (P < .05). Areas of high contact were associated with skin erythema and pressure ulcers. This fit method is currently being utilized to select best-fit masks from available options, to identify the potential areas of increased tissue pressure, and to prevent skin injuries and their complications. Improvement of mask fit is an important priority for improving respiratory outcomes. Strategies to maintain normal skin hydration are important for protecting tissue integrity. Copyright © 2015 by Daedalus Enterprises.

  3. A conservative approach to perineal Fournier's gangrene.

    PubMed

    Milanese, Giulio; Quaresima, Luigi; Dellabella, Marco; Scalise, Alessandro; Di Benedetto, Giovanni Maria; Muzzonigro, Giovanni; Minardi, Daniele

    2015-03-31

    Fournier's gangrene (FG) is a disease involving necrosis of perineum and external genitalia; in 95% of cases it is possible to diagnose the Fournier's gangrene just by physical examination. The clinical presentation of FG varies from an initial localized infection to large areas with necrotizing infection. The disease typically affect elderly men (6°-7° decade) with important systemic comorbidities; women are less frequently affected. Despite improvements in diagnosis and management, the mortality rate nowadays is between 20% and 43%. The severity and mortality of the disease is dependent upon the general condition of the patient at presentation and upon the rate of spread of the infection. Treatment involves a multidisciplinary approach: intensive systematic management, broad-spectrum antibiotic therapy, early surgical debridement (wide abscission of necrotic tissues and surgical drainage of peritoneum, scrotum, penis, and inguinal areas), hyperbaric oxygen therapy; surgery can eventually be repeated if necessary; reconstructive surgery has an important role in the final treatment of the disease. The technical difficulties frequently encountered and the inability to make a complete removal of the necrotizing tissues at the time of surgery in some cases has led to the application of combined techniques, in view of the enhancement effect of specific advanced medications, targeted antibiotic therapy and hyperbaric medicine. We have considered 6 patients affected by Fournier's gangrene treated at our institution; all the patients received treatment with the help of plastic surgeons of the same institution. After debridement, all the patients were treated with advanced specific dressings consisting of plates and strips made of calcium alginate, hydrogels and polyurethane and twodimensional cavity foams. Reconstructive surgery was necessary in one case. Hyperbaric oxygen therapy (HBO) has been performed in all cases. The multidisciplinary approach, the combined use of HBO therapy and the adoption of advanced specific dressings, have made possible the complete healing of the lesions in a shorter period, avoiding further surgery in 5 out of 6 patients.

  4. Innovative dressing and securement of tunneled central venous access devices in pediatrics: a pilot randomized controlled trial.

    PubMed

    Ullman, Amanda J; Kleidon, Tricia; Gibson, Victoria; McBride, Craig A; Mihala, Gabor; Cooke, Marie; Rickard, Claire M

    2017-08-30

    Central venous access device (CVAD) associated complications are a preventable source of patient harm, frequently resulting in morbidity and delays to vital treatment. Dressing and securement products are used to prevent infectious and mechanical complications, however current complication rates suggest customary practices are inadequate. The aim of this study was to evaluate the feasibility of launching a full-scale randomized controlled efficacy trial of innovative dressing and securement products for pediatric tunneled CVAD to prevent complication and failure. An external, pilot, four-group randomized controlled trial of standard care (bordered polyurethane dressing and suture), in comparison to integrated securement-dressing, suture-less securement device, and tissue adhesive was undertaken across two large, tertiary referral pediatric hospitals in Australia. Forty-eight pediatric participants with newly inserted tunneled CVADs were consecutively recruited. The primary outcome of study feasibility was established by elements of eligibility, recruitment, attrition, protocol adherence, missing data, parent and healthcare staff satisfaction and acceptability, and effect size estimates for CVAD failure (cessation of function prior to completion of treatment) and complication (associated bloodstream infection, thrombosis, breakage, dislodgement or occlusion). Dressing integrity, product costs and site complications were also examined. Protocol feasibility was established. CVAD failure was: 17% (2/12) integrated securement-dressing; 8% (1/13) suture-less securement device; 0% tissue adhesive (0/12); and, 0% standard care (0/11). CVAD complications were: 15% (2/13) suture-less securement device (CVAD associated bloodstream infection, and occlusion and partial dislodgement); 8% (1/12) integrated securement-dressing (partial dislodgement); 0% tissue adhesive (0/12); and, 0% standard care (0/11). One CVAD-associated bloodstream infection occurred, within the suture-less securement device group. Overall satisfaction was highest in the integrated securement-dressing (mean 8.5/10; standard deviation 1.2). Improved dressing integrity was evident in the intervention arms, with the integrated securement-dressing associated with prolonged time to first dressing change (mean days 3.5). Improving the security and dressing integrity of tunneled CVADs is likely to improve outcomes for pediatric patients. Further research is necessary to identify novel, effective CVAD securement to reduce complications, and provide reliable vascular access for children. ACTRN12614000280606 ; prospectively registered on 17/03/2014.

  5. Effects of sulfur impregnation temperature on the properties and mercury adsorption capacities of activated carbon fibers (ACFs)

    USGS Publications Warehouse

    Hsi, H.-C.; Rood, M.J.; Rostam-Abadi, M.; Chen, S.; Chang, R.

    2001-01-01

    Laboratory studies were conducted to determine the role of sulfur functional groups and micropore surface area of carbon-based adsorbents on the adsorption of Hg0 from simulated coal combustion flue gases. In this study, raw activated carbon fibers that are microporous (ACF-20) were impregnated with elemental sulfur between 250 and 650 ??C. The resulting samples were saturated with respect to sulfur content. Total sulfur content of the sulfur impregnated ACF samples decreased with increasing impregnation temperatures from 250 and 500 ??C and then remained constant to 650 ??C. Results from sulfur K-edge X-ray absorption near-edge structure (S-XANES) spectroscopy showed that sulfur impregnated on the ACF samples was in both elemental and organic forms. As sulfur impregnation temperature increased, however, the relative amounts of elemental sulfur decreased with a concomitant increase in the amount of organic sulfur. Thermal analyses and mass spectrometry revealed that sulfur functional groups formed at higher impregnation temperatures were more thermally stable. In general, sulfur impregnation decreased surface area and increased equilibrium Hg0 adsorption capacity when compared to the raw ACF sample. The ACF sample treated with sulfur at 400 ??C had a surface area of only 94 m2/g compared to the raw ACF sample's surface area of 1971 m2/g, but at least 86% of this sample's surface area existed as micropores and it had the largest equilibrium Hg0adsorption capacities (2211-11343 ??g/g). Such a result indicates that 400 ??C is potentially an optimal sulfur impregnation temperature for this ACF. Sulfur impregnated on the ACF that was treated at 400 ??C was in both elemental and organic forms. Thermal analyses and CS2extraction tests suggested that elemental sulfur was the main form of sulfur affecting the Hg0 adsorption capacity. These findings indicate that both the presence of elemental sulfur on the adsorbent and a microporous structure are important properties for improving the performance of carbon-based adsorbents for the removal of Hg0 from coal combustion flue gases.

  6. Percutaneous urinary procedures - discharge

    MedlinePlus

    ... a shower if you wrap the dressing with plastic wrap and replace the dressing if it gets ... include: Telfa (the dressing material), Tegaderm (the clear plastic tape that holds the plastic ring in place), ...

  7. Prospective randomised controlled trial of nanocrystalline silver dressing versus plain gauze as the initial post-debridement management of military wounds on wound microbiology and healing.

    PubMed

    Fries, C A; Ayalew, Y; Penn-Barwell, J G; Porter, K; Jeffery, S L A; Midwinter, M J

    2014-07-01

    Recent conflicts have been characterised by the use of improvised explosive devices causing devastating injuries, including heavily contaminated wounds requiring meticulous surgical debridement. After being rendered surgical clean, these wounds are dressed and the patient transferred back to the UK for on-going treatment. A dressing that would prevent wounds from becoming colonised during transit would be desirable. The aim of this study was to establish whether using nanocrystalline silver dressings, as an adjunct to the initial debridement, would positively affect wound microbiology and wound healing compared to standard plain gauze dressings. Patients were prospectively randomised to receive either silver dressings, in a nanocrystalline preparation (Acticoat™), or standard of care dressings (plain gauze) following their initial debridement in the field hospital. On repatriation to the UK microbiological swabs were taken from the dressing and the wound, and an odour score recorded. Wounds were followed prospectively and time to wound healing was recorded. Additionally, patient demographic data were recorded, as well as the mechanism of injury and Injury Severity Score. 76 patients were recruited to the trial between February 2010 and February 2012. 39 received current dressings and 37 received the trial dressings. Eleven patients were not swabbed. There was no difference (p=0.1384, Fishers) in the primary outcome measure of wound colonisation between the treatment arm (14/33) and the control arm (20/32). Similarly time to wound healing was not statistically different (p=0.5009, Mann-Whitney). Wounds in the control group were scored as being significantly more malodorous (p=0.002, Mann-Whitney) than those in the treatment arm. This is the first randomised controlled trial to report results from an active theatre of war. Performing research under these conditions poses additional challenges to military clinicians. Meticulous debridement of wounds remains the critical determinant in wound healing and infection and this study did not demonstrate a benefit of nanocrystaline silver dressing in respect to preventing wound colonisation or promoting healing, these dressings do however seem to significantly reduce the unpleasant odour commonly associated with battlefield wounds. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  8. Effects of properties of manganese oxide-impregnated catalysts and flue gas condition on multipollutant control of Hg0 and NO.

    PubMed

    Chiu, Chun-Hsiang; Hsi, Hsing-Cheng; Lin, Hong-Ping; Chang, Tien-Chin

    2015-06-30

    This research investigated the effects of manganese oxide (MnOx) impregnation on the physical/chemical properties and multi pollutant control effectiveness of Hg(0) and NO using a V2O5-WO3/TiO2-SiO2 selective catalytic reduction (SCR) catalyst. Raw and MnOx-treated SCR samples were bean-shaped nanoparticles with sizes within 10-30 nm. Impregnating MnOx of ≤ 5 wt% caused limited changes in physical properties of the catalyst. The decrease in surface area when the impregnated MnOx amount was 10 wt% may stem from the pore blockage and particle growth or aggregation of the catalyst. Mn(4+) was the main valence state of impregnated MnOx. Apparent crystallinity of MnOx was not observed based on X-ray diffraction. MnOx impregnation enhanced the Hg(0) oxidation and NO/SO2 removal of SCR catalyst. The 5 and 10% MnOx-impregnated samples had the greatest multi pollutant control potentials for Hg(0) oxidation and NO removal; however, the increasing SO2 removal that may be mainly due to SO2-SO3 conversion should be cautioned. HCl and O2 greatly promoted Hg(0) oxidation. SO2 enhanced Hg(0) oxidation at ≤ 200 ppm while NO and NH3 consistently inhibited Hg(0) oxidation. Elevating flue gas temperature enhanced Hg(0) oxidation. Overall, MnOx-impregnated catalysts show stable and consistent multi pollutant removal effectiveness under the test conditions. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Cost-Effectiveness Analysis of a Transparent Antimicrobial Dressing for Managing Central Venous and Arterial Catheters in Intensive Care Units

    PubMed Central

    Bernatchez, Stéphanie F.; Ruckly, Stéphane; Timsit, Jean-François

    2015-01-01

    Objective To model the cost-effectiveness impact of routine use of an antimicrobial chlorhexidine gluconate-containing securement dressing compared to non-antimicrobial transparent dressings for the protection of central vascular lines in intensive care unit patients. Design This study uses a novel health economic model to estimate the cost-effectiveness of using the chlorhexidine gluconate dressing versus transparent dressings in a French intensive care unit scenario. The 30-day time non-homogeneous markovian model comprises eight health states. The probabilities of events derive from a multicentre (12 French intensive care units) randomized controlled trial. 1,000 Monte Carlo simulations of 1,000 patients per dressing strategy are used for probabilistic sensitivity analysis and 95% confidence intervals calculations. The outcome is the number of catheter-related bloodstream infections avoided. Costs of intensive care unit stay are based on a recent French multicentre study and the cost-effectiveness criterion is the cost per catheter-related bloodstream infections avoided. The incremental net monetary benefit per patient is also estimated. Patients 1000 patients per group simulated based on the source randomized controlled trial involving 1,879 adults expected to require intravascular catheterization for 48 hours. Intervention Chlorhexidine Gluconate-containing securement dressing compared to non-antimicrobial transparent dressings. Results The chlorhexidine gluconate dressing prevents 11.8 infections /1,000 patients (95% confidence interval: [3.85; 19.64]) with a number needed to treat of 85 patients. The mean cost difference per patient of €141 is not statistically significant (95% confidence interval: [€-975; €1,258]). The incremental cost-effectiveness ratio is of €12,046 per catheter-related bloodstream infection prevented, and the incremental net monetary benefit per patient is of €344.88. Conclusions According to the base case scenario, the chlorhexidine gluconate dressing is more cost-effective than the reference dressing. Trial Registration This model is based on the data from the RCT registered with www.clinicaltrials.gov (NCT01189682). PMID:26086783

  10. Antibacterial properties and reduction of MRSA biofilm with a dressing combining polyabsorbent fibres and a silver matrix.

    PubMed

    Desroche, N; Dropet, C; Janod, P; Guzzo, J

    2016-10-02

    This study was designed to evaluate the antibacterial activity of a wound dressing which combines polyacrylate fibres and a silver lipido-colloid matrix (UrgoClean Ag, silver polyabsorbent dressing), against biofilm of methicillin-resistant Staphylococcus aureus (MRSA). Samples of silver polyabsorbent dressing and the neutral form of this dressing (UrgoClean) were applied to biofilms of MRSA formed on a collagen I-coated surface, cultured for 24 hours. Different exposure times were tested (1, 2, 4 and 7 days) without dressing change. The biofilm reduction was quantified by using culture methods and by confocal laser scanning microscopy experiments. The application of the silver polyabsorbent dressing resulted in a significant decrease of the biofilm population by a log reduction of 4.6, after 24 hours of exposure. Moreover, the antibiofilm activity was maintained for 7 days with reduction values up to 4 log (reduction of biofilm superior to 99.99%). The application of the neutral dressing also induced a significant reduction of the concentration of sessile cells after 1 day (about 0.90 log). The results obtained with this neutral form of the dressing showed that the polyacrylate fibres were able to exert a mechanical disruption of the biofilm architecture. These in vitro experiments demonstrated that silver polyabsorbent dressing was able to strongly reduce the biofilm of MRSA. The antibiofilm mechanism of this dressing can be explained by a dual action of the polyabsorbent fibres (based on ammonium polyacrylate polymer around an acrylic core) which induced a mechanical disruption of the biofilm matrix and/or a sequestration of sessile cells, and the diffusion of silver ions which produced bactericidal activity. This study was supported by Laboratoires Urgo (Dijon). P. Janod is an employee of Laboratoires Urgo. The company had no influence on the experimental design and the interpretation of the results.

  11. Antibacterial properties of tualang honey and its effect in burn wound management: a comparative study

    PubMed Central

    2010-01-01

    Background The use of honey as a natural product of Apis spp. for burn treatment has been widely applied for centuries. Tualang honey has been reported to have antibacterial properties against various microorganisms, including those from burn-related diagnoses, and is cheaper and easier to be absorbed by Aquacel dressing. The aim of this study is to evaluate the potential antibacterial properties of tualang honey dressing and to determine its effectiveness as a partial thickness burn wound dressing. Methods In order to quantitate the bioburden of the swabs, pour plates were performed to obtain the colony count (CFU/ml). Swabs obtained from burn wounds were streaked on blood agar and MacConkey agar for bacterial isolation and identification. Later, antibacterial activity of Aquacel-tualang honey, Aquacel-Manuka honey, Aquacel-Ag and Aquacel- plain dressings against bacteria isolated from patients were tested (in-vitro) to see the effectiveness of those dressings by zone of inhibition assays. Results Seven organisms were isolated. Four types of Gram-negative bacteria, namely Enterobacter cloacae, Klebsiella pneumoniae, Pseudomonas spp. and Acinetobacter spp., and three Gram-positive bacteria, namely Staphylococcus aureus, coagulase-negative Staphylococcus aureus (CONS) and Streptococcus spp., were isolated. Total bacterial count decreased on day 6 and onwards. In the in-vitro antibacterial study, Aquacel-Ag and Aquacel-Manuka honey dressings gave better zone of inhibition for Gram positive bacteria compared to Aquacel-Tualang honey dressing. However, comparable results were obtained against Gram negative bacteria tested with Aquacel-Manuka honey and Aquacel-Tualang honey dressing. Conclusions Tualang honey has a bactericidal as well as bacteriostatic effect. It is useful as a dressing, as it is easier to apply and is less sticky compared to Manuka honey. However, for Gram positive bacteria, tualang honey is not as effective as usual care products such as silver-based dressing or medical grade honey dressing. PMID:20576085

  12. Antibacterial properties of tualang honey and its effect in burn wound management: a comparative study.

    PubMed

    Nasir, Nur-Azida Mohd; Halim, Ahmad Sukari; Singh, Kirnpal-Kaur Banga; Dorai, Ananda Aravazhi; Haneef, Mehru-Nisha Muhammad

    2010-06-24

    The use of honey as a natural product of Apis spp. for burn treatment has been widely applied for centuries. Tualang honey has been reported to have antibacterial properties against various microorganisms, including those from burn-related diagnoses, and is cheaper and easier to be absorbed by Aquacel dressing. The aim of this study is to evaluate the potential antibacterial properties of tualang honey dressing and to determine its effectiveness as a partial thickness burn wound dressing. In order to quantitate the bioburden of the swabs, pour plates were performed to obtain the colony count (CFU/ml). Swabs obtained from burn wounds were streaked on blood agar and MacConkey agar for bacterial isolation and identification. Later, antibacterial activity of Aquacel-tualang honey, Aquacel-Manuka honey, Aquacel-Ag and Aquacel- plain dressings against bacteria isolated from patients were tested (in-vitro) to see the effectiveness of those dressings by zone of inhibition assays. Seven organisms were isolated. Four types of Gram-negative bacteria, namely Enterobacter cloacae, Klebsiella pneumoniae, Pseudomonas spp. and Acinetobacter spp., and three Gram-positive bacteria, namely Staphylococcus aureus, coagulase-negative Staphylococcus aureus (CONS) and Streptococcus spp., were isolated. Total bacterial count decreased on day 6 and onwards. In the in-vitro antibacterial study, Aquacel-Ag and Aquacel-Manuka honey dressings gave better zone of inhibition for Gram positive bacteria compared to Aquacel-Tualang honey dressing. However, comparable results were obtained against Gram negative bacteria tested with Aquacel-Manuka honey and Aquacel-Tualang honey dressing. Tualang honey has a bactericidal as well as bacteriostatic effect. It is useful as a dressing, as it is easier to apply and is less sticky compared to Manuka honey. However, for Gram positive bacteria, tualang honey is not as effective as usual care products such as silver-based dressing or medical grade honey dressing.

  13. 76 FR 14910 - Small Diameter Graphite Electrodes From the People's Republic of China: Initiation of Anti...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    ... correct grade of petroleum coke mix, and have been baked, formed, carbonized, impregnated, and graphitized... required for the production of SDGE (e.g., raw material handling, mixing, forming, baking, impregnating... production process, demonstrating how raw materials are formed, baked, impregnated (if needed), re-baked...

  14. Predicting the effectiveness of virtual reality relaxation on pain and anxiety when added to PCA morphine in patients having burns dressings changes.

    PubMed

    Konstantatos, A H; Angliss, M; Costello, V; Cleland, H; Stafrace, S

    2009-06-01

    Pain arising in burns sufferers is often severe and protracted. The prospect of a dressing change can heighten existing pain by impacting both physically and psychologically. In this trial we examined whether pre-procedural virtual reality guided relaxation added to patient controlled analgesia with morphine reduced pain severity during awake dressings changes in burns patients. We conducted a prospective randomized clinical trial in all patients with burns necessitating admission to a tertiary burns referral centre. Eligible patients requiring awake dressings changes were randomly allocated to single use virtual reality relaxation plus intravenous morphine patient controlled analgesia (PCA) infusion or to intravenous morphine patient controlled analgesia infusion alone. Patients rated their worst pain intensity during the dressing change using a visual analogue scale. The primary outcome measure was presence of 30% or greater difference in pain intensity ratings between the groups in estimation of worst pain during the dressing change. Of 88 eligible and consenting patients having awake dressings changes, 43 were assigned to virtual reality relaxation plus intravenous morphine PCA infusion and 43 to morphine PCA infusion alone. The group receiving virtual reality relaxation plus morphine PCA infusion reported significantly higher pain intensities during the dressing change (mean=7.3) compared with patients receiving morphine PCA alone (mean=5.3) (p=0.003) (95% CI 0.6-2.8). The addition of virtual reality guided relaxation to morphine PCA infusion in burns patients resulted in a significant increase in pain experienced during awake dressings changes. In the absence of a validated predictor for responsiveness to virtual reality relaxation such a therapy cannot be recommended for general use in burns patients having awake dressings changes.

  15. A comparison of skin graft success in the head & neck with and without the use of a pressure dressing.

    PubMed

    Dhillon, M; Carter, C P; Morrison, J; Hislop, W S; Currie, W J R

    2015-06-01

    The success of skin grafting is dependent on the interplay between many factors including nutrient uptake and vascular in-growth. To allow this, it is important that the graft is immobile and traditionally a 'pressure dressing' has been placed over the graft to improve outcome and graft 'take'. We present the findings of our comparative study of full-thickness skin grafts performed in the head, neck and face region over a period of 24 months. We felt that there was an unacceptably high infection rate and graft failure using pressure dressings. Data was collected retrospectively from the case notes on 70 patients who had undergone full-thickness skin grafting to the head, neck and face over a 2 year period. Thirty-five patients underwent grafting with pressure dressing and 35 without. The group with the pressure dressing had the same 'bolster' specification-type dressing and those without had their graft 'quilted' in and chloramphenicol ointment applied topically. Success was determined by the percentage 'take' of the grafts and absence of infection i.e. purulence. Infection in those with a pressure dressing stood at 26 % in contrast to those without, at 9 %. Without a pressure dressing we observed no total graft failures, compared to 6 % in those with a pressure dressing. The results confirmed the perception that there was a higher infection and graft failure rate where a pressure dressing was applied; however, this was not a statistically significant difference and a randomised control trial with a larger sample size would be required to validate the results.

  16. Economic and clinical contributions of an antimicrobial barrier dressing: a strategy for the reduction of surgical site infections.

    PubMed

    Leaper, David; Nazir, Jameel; Roberts, Chris; Searle, Richard

    2010-01-01

    In patients at risk of surgical site infection (SSI), there is evidence that an antimicrobial barrier dressing (Acticoat* ) applied immediately post-procedure is effective in reducing the incidence of infection. The objective of this study was to assess when it is appropriate to use an antimicrobial barrier dressing rather than a post-operative film dressing, by evaluating the net cost and budget impact of the two strategies. An economic model was developed, which estimates expected expenditure on dressings and the expected costs of surgical site infection during the initial inpatient episode, based on published literature on the pre-discharge costs of surgical infection and the efficacy of an antimicrobial barrier dressing in preventing SSI. At an SSI risk of 10%, an antimicrobial barrier dressing strategy is cost neutral if the incidence of infection is reduced by at least 9% compared with a post-operative film dressing. At 35% efficacy, expenditure on dressings would be higher by £30,760 per 1000 patients, and the cost of treating infection would be lower by £111,650, resulting in a net cost saving of £80,890. The break-even infection risk for cost neutrality is 2.6%. Although this cost analysis is based on published data, there are limitations in methodology: the model is dependent on and subject to the limitations of the data used to populate it. Further studies would be useful to increase the robustness of the conclusions, particularly in a broader range of surgical specialties. A strategy involving the use of an antimicrobial barrier dressing in patients at moderate (5-10%) or high (>10%) risk of infection appears reasonable and cost saving in light of the available clinical evidence.

  17. Pesticide seed dressings can affect the activity of various soil organisms and reduce decomposition of plant material.

    PubMed

    Zaller, Johann G; König, Nina; Tiefenbacher, Alexandra; Muraoka, Yoko; Querner, Pascal; Ratzenböck, Andreas; Bonkowski, Michael; Koller, Robert

    2016-08-17

    Seed dressing with pesticides is widely used to protect crop seeds from pest insects and fungal diseases. While there is mounting evidence that especially neonicotinoid seed dressings detrimentally affect insect pollinators, surprisingly little is known on potential side effects on soil biota. We hypothesized that soil organisms would be particularly susceptible to pesticide seed dressings as they get in direct contact with these chemicals. Using microcosms with field soil we investigated, whether seeds treated either with neonicotinoid insecticides or fungicides influence the activity and interaction of earthworms, collembola, protozoa and microorganisms. The full-factorial design consisted of the factor Seed dressing (control vs. insecticide vs. fungicide), Earthworm (no earthworms vs. addition Lumbricus terrestris L.) and collembola (no collembola vs. addition Sinella curviseta Brook). We used commercially available wheat seed material (Triticum aesticum L. cf. Lukullus) at a recommended seeding density of 367 m(-2). Seed dressings (particularly fungicides) increased collembola surface activity, increased the number of protozoa and reduced plant decomposition rate but did not affect earthworm activity. Seed dressings had no influence on wheat growth. Earthworms interactively affected the influence of seed dressings on collembola activity, whereas collembola increased earthworm surface activity but reduced soil basal respiration. Earthworms also decreased wheat growth, reduced soil basal respiration and microbial biomass but increased soil water content and electrical conductivity. The reported non-target effects of seed dressings and their interactions with soil organisms are remarkable because they were observed after a one-time application of only 18 pesticide treated seeds per experimental pot. Because of the increasing use of seed dressing in agriculture and the fundamental role of soil organisms in agroecosystems these ecological interactions should receive more attention.

  18. Impacts of amount of impregnated iron in granular activated carbon on arsenate adsorption capacities and kinetics.

    PubMed

    Chang, Qigang; Lin, Wei; Ying, Wei-Chi

    2012-06-01

    Iron-impregnated granular activated carbons (Fe-GAC) can remove arsenic effectively from water. In this study, Fe-GACs with iron content of 1.64 to 28.90% were synthesized using a new multi-step procedure for the investigation of effects of iron amount on arsenic adsorption capacities and kinetics. Langmuir model satisfactorily fit arsenic adsorption on Fe-GACs. The maximum arsenic adsorption capacity (q(m)) increased significantly with iron impregnation and reached 1,867 to 1,912 microg/g with iron content of 9.96 to 13.59%. Further increase of iron content (> 13.59%) caused gradual decrease of q(m). It was found that the amount of impregnated iron showed little impact on the affinity for arsenate. Kinetic study showed that the amount of impregnated iron affected the arsenic intraparticle diffusion rate greatly. The pseudo-second-order kinetic model fit arsenic adsorption kinetics on Fe-GACs better than the pseudo-first-order model. The arsenic adsorption rate increased with increasing of iron content from 1.64% to 13.59%, and then decreased with more impregnated iron (13.59 to 28.90%).

  19. Selection of best impregnated palm shell activated carbon (PSAC) for simultaneous removal of SO2 and NOx.

    PubMed

    Sumathi, S; Bhatia, S; Lee, K T; Mohamed, A R

    2010-04-15

    This work examines the impregnated carbon-based sorbents for simultaneous removal of SO(2) and NOx from simulated flue gas. The carbon-based sorbents were prepared using palm shell activated carbon (PSAC) impregnated with several metal oxides (Ni, V, Fe and Ce). The removal of SO(2) and NOx from the simulated flue gas was investigated in a fixed-bed reactor. The results showed that PSAC impregnated with CeO(2) (PSAC-Ce) reported the highest sorption capacity among other impregnated metal oxides for the simultaneous removal of SO(2) and NOx. PSAC-Ce showed the longest breakthrough time of 165 and 115 min for SO(2) and NOx, respectively. The properties of the pure and impregnated PSAC were analyzed by BET, FTIR and XRF. The physical-chemical features of the PSAC-Ce sorbent indicated a catalytic activity in both the sorption of SO(2) and NOx. The formation of both sulfate (SO(4)(2-)) and nitrate (NO(3-)) species on spent PSAC-Ce further prove the catalytic role played by CeO(2). 2009 Elsevier B.V. All rights reserved.

  20. Early versus delayed dressing removal after primary closure of clean and clean-contaminated surgical wounds.

    PubMed

    Toon, Clare D; Lusuku, Charnelle; Ramamoorthy, Rajarajan; Davidson, Brian R; Gurusamy, Kurinchi Selvan

    2015-09-03

    Most surgical procedures involve a cut in the skin that allows the surgeon to gain access to the deeper tissues or organs. Most surgical wounds are closed fully at the end of the procedure (primary closure). The surgeon covers the closed surgical wound with either a dressing or adhesive tape. The dressing can act as a physical barrier to protect the wound until the continuity of the skin is restored (within about 48 hours) and to absorb exudate from the wound, keeping it dry and clean, and preventing bacterial contamination from the external environment. Some studies have found that the moist environment created by some dressings accelerates wound healing, although others believe that the moist environment can be a disadvantage, as excessive exudate can cause maceration (softening and deterioration) of the wound and the surrounding healthy tissue. The utility of dressing surgical wounds beyond 48 hours of surgery is, therefore, controversial. To evaluate the benefits and risks of removing a dressing covering a closed surgical incision site within 48 hours permanently (early dressing removal) or beyond 48 hours of surgery permanently with interim dressing changes allowed (delayed dressing removal), on surgical site infection. In March 2015 we searched the following electronic databases: The Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Database of Abstracts of Reviews of Effects (DARE) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. We also searched the references of included trials to identify further potentially-relevant trials. Two review authors independently identified studies for inclusion. We included all randomised clinical trials (RCTs) conducted with people of any age and sex, undergoing a surgical procedure, who had their wound closed and a dressing applied. We included only trials that compared early versus delayed dressing removal. We excluded trials that included people with contaminated or dirty wounds. We also excluded quasi-randomised studies, and other study designs. Two review authors independently extracted data on the characteristics of the trial participants, risk of bias in the trials and outcomes for each trial. We calculated risk ratios (RR) with 95% confidence intervals (CI) for binary outcomes and mean difference (MD) with 95% CI for continuous outcomes. We used RevMan 5 software to perform these calculations. Four trials were identified for inclusion in this review. All the trials were at high risk of bias. Three trials provided information for this review. Overall, this review included 280 people undergoing planned surgery. Participants were randomised to early dressing removal (removal of the wound dressing within the 48 hours following surgery) (n = 140) or delayed dressing removal (continued dressing of the wound beyond 48 hours) (n = 140) in the three trials. There were no statistically significant differences between the early dressing removal group and delayed dressing removal group in the proportion of people who developed superficial surgical site infection within 30 days (RR 0.64; 95% CI 0.32 to 1.28), superficial wound dehiscence within 30 days (RR 2.00; 95% CI 0.19 to 21.16) or serious adverse events within 30 days (RR 0.83; 95% CI 0.28 to 2.51). No deep wound infection or deep wound dehiscence occurred in any of the participants in the trials that reported this outcome. None of the trials reported quality of life. The hospital stay was significantly shorter (MD -2.00 days; 95% CI -2.82 to -1.18) and the total cost of treatment significantly less (MD EUR -36.00; 95% CI -59.81 to -12.19) in the early dressing removal group than in the delayed dressing removal group in the only trial that reported these outcomes. The early removal of dressings from clean or clean contaminated surgical wounds appears to have no detrimental effect on outcomes. However, it should be noted that the point estimate supporting this statement is based on very low quality evidence from three small randomised controlled trials, and the confidence intervals around this estimate were wide. Early dressing removal may result in a significantly shorter hospital stay, and significantly reduced costs, than covering the surgical wound with wound dressings beyond the first 48 hours after surgery, according to very low quality evidence from one small randomised controlled trial. Further randomised controlled trials of low risk of bias are necessary to investigate whether dressings are necessary after 48 hours in different types of surgery and levels of contamination and investigate whether antibiotic therapy influences the outcome.

  1. Early versus delayed dressing removal after primary closure of clean and clean-contaminated surgical wounds.

    PubMed

    Toon, Clare D; Ramamoorthy, Rajarajan; Davidson, Brian R; Gurusamy, Kurinchi Selvan

    2013-09-05

    Most surgical procedures involve a cut in the skin that allows the surgeon to gain access to the deeper tissues or organs. Most surgical wounds are closed fully at the end of the procedure (primary closure). The surgeon covers the closed surgical wound with either a dressing or adhesive tape. The dressing can act as a physical barrier to protect the wound until the continuity of the skin is restored (within about 48 hours) and to absorb exudate from the wound, keeping it dry and clean, and preventing bacterial contamination from the external environment. Some studies have found that the moist environment created by some dressings accelerates wound healing, although others believe that the moist environment can be a disadvantage, as excessive exudate can cause maceration (softening and deterioration) of the wound and the surrounding healthy tissue. The utility of dressing surgical wounds beyond 48 hours of surgery is, therefore, controversial. To evaluate the benefits and risks of removing a dressing covering a closed surgical incision site within 48 hours permanently (early dressing removal) or beyond 48 hours of surgery permanently with interim dressing changes allowed (delayed dressing removal), on surgical site infection. In July 2013 we searched the following electronic databases: The Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Database of Abstracts of Reviews of Effects (DARE) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. We also searched the references of included trials to identify further potentially-relevant trials. Two review authors independently identified studies for inclusion. We included all randomised clinical trials (RCTs) conducted with people of any age and sex, undergoing a surgical procedure, who had their wound closed and a dressing applied. We included only trials that compared early versus delayed dressing removal. We excluded trials that included people with contaminated or dirty wounds. We also excluded quasi-randomised studies, and other study designs. Two review authors independently extracted data on the characteristics of the trial participants, risk of bias in the trials and outcomes for each trial. We calculated risk ratios (RR) with 95% confidence intervals (CI) for binary outcomes and mean difference (MD) with 95% CI for continuous outcomes. We used RevMan 5 software to perform these calculations. Four trials were identified for inclusion in this review. All the trials were at high risk of bias. Three trials provided information for this review. Overall, this review included 280 people undergoing planned surgery. Participants were randomised to early dressing removal (removal of the wound dressing within the 48 hours following surgery) (n = 140) or delayed dressing removal (continued dressing of the wound beyond 48 hours) (n = 140) in the three trials. There were no statistically significant differences between the early dressing removal group and delayed dressing removal group in the proportion of people who developed superficial surgical site infection within 30 days (RR 0.64; 95% CI 0.32 to 1.28), superficial wound dehiscence within 30 days (RR 2.00; 95% CI 0.19 to 21.16) or serious adverse events within 30 days (RR 0.83; 95% CI 0.28 to 2.51). No deep wound infection or deep wound dehiscence occurred in any of the participants in the trials that reported this outcome. None of the trials reported quality of life. The hospital stay was significantly shorter (MD -2.00 days; 95% CI -2.82 to -1.18) and the total cost of treatment significantly less (MD EUR -36.00; 95% CI -59.81 to -12.19) in the early dressing removal group than in the delayed dressing removal group in the only trial that reported these outcomes. The early removal of dressings from clean or clean contaminated surgical wounds appears to have no detrimental effect on outcomes. However, it should be noted that the point estimate supporting this statement is based on very low quality evidence from three small randomised controlled trials, and the confidence intervals around this estimate were wide. Early dressing removal may result in a significantly shorter hospital stay, and significantly reduced costs, than covering the surgical wound with wound dressings beyond the first 48 hours after surgery, according to very low quality evidence from one small randomised controlled trial. Further randomised controlled trials of low risk of bias are necessary to investigate whether dressings are necessary after 48 hours in different types of surgery and levels of contamination and investigate whether antibiotic therapy influences the outcome.

  2. Vaginal contraceptive film gains wider acceptance.

    PubMed

    1992-09-01

    In US health departments and family planning clinics, women are beginning to accept vaginal contraceptive film more widely. Further, direct sales of this method, which is also distributed over the counter, has increased. In fact, in 1991, vaginal contraceptive film was the top selling contraceptive in pharmacies. This 2.5 sq. inch water-soluble film is impregnated with nonoxynol-9. The woman uses her finger to insert the folded square as close as possible to the cervix 5-60 minutes before intercourse. If the time between acts of intercourse is greater than 1 hour, she must insert another square. After it dissolves, it is a firm gel removed by vaginal and cervical fluids. The company realizes that its relatively high cost (about $3.59 for 3 films) prevents some family planning providers from offering the film. It has tried to cut costs by not using extra packaging material and by manufacturing it in the US instead of ain England. A manager of the family planning clinic at R.E. Thomason County Hospital in El Paso, Texas, notes that user compliance is higher with the vaginal contraceptive film than foam. In fact, patients at the Planned Parenthood League of Middlesex County, New Jersey, favor the film because it is less messy than foam. Teenagers in El Paso prefer the film because of the privacy issue and gives them more control to protect themselves from pregnancy. A worker at the New Jersey clinic recommends the film as a backup method for women beginning to use oral contraceptives. She also suggests to patients requesting condoms to also use the film. The company makes the same recommendation. Yet, family planning workers note that some women cannot convince partners to use the condom. 90% of patients at the El Paso clinic are Hispanic, and they tend to not accept condom use. Some providers suggest using 2 applications of the film to defend against sexually transmitted diseases, but there is no evidence that double application actually does so.

  3. Pediatric Digital Necrosis Secondary to Dressing Application: A Case Series.

    PubMed

    Bjorklund, Kim A; Rice, Dahlia M; Amalfi, Ashley N

    2018-04-01

    Pediatric digital necrosis resulting in revision amputation is a devastating outcome following digital dressing application. We report a series of 4 pediatric patients (age: 21 months-11 years) who presented for surgical consultation related to digital ischemia and irreversible necrosis following the application of Coban digital dressings. A review of the literature demonstrated that such injuries had not previously been described. In our case series, Coban dressing was utilized as a deterrent for thumb sucking, fingertip tuft fractures with nail bed lacerations, and a phalanx fracture secondary to crush injury. All 4 children suffered digital necrosis secondary to Coban dressings and ultimately required revision amputation. We discuss risks factors, application practices, and strategies to minimize complications with digital dressings in the pediatric population with the intent of creating awareness among hand surgeons to help promote safe practices and improve patient outcomes.

  4. Enhancing pressure ulcer prevention using wound dressings: what are the modes of action?

    PubMed

    Call, Evan; Pedersen, Justin; Bill, Brian; Black, Joyce; Alves, Paulo; Brindle, C Tod; Dealey, Carol; Santamaria, Nick; Clark, Michael

    2015-08-01

    Recent clinical research has generated interest in the use of sacral wound dressings as preventive devices for patients at risk of ulceration. This study was conducted to identify the modes of action through which dressings can add to pressure ulcer prevention, for example, shear and friction force redistribution and pressure distribution. Bench testing was performed using nine commercially available dressings. The use of dressings can reduce the amplitude of shear stress and friction reaching the skin of patients at risk. They can also effectively redirect these forces to wider areas which minimises the mechanical loads upon skeletal prominences. Dressings can redistribute pressure based upon their effective Poisson ratio and larger deflection areas, providing greater load redistribution. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  5. A comparison of a modified form of Granuflex (Granuflex Extra Thin) and a conventional dressing in the management of lacerations, abrasions and minor operation wounds in an accident and emergency department.

    PubMed Central

    Heffernan, A; Martin, A J

    1994-01-01

    A clinical study of 96 patients compared a new hydrocolloid dressing (Granuflex Extra Thin) with a non-adherent dressing (perforated film absorbent dressing) in the management of lacerations, abrasions and minor operation incisions at the Accident and Emergency (A&E) Department of the University College Hospital, Galway. While time to heal was similar for both groups, the patients using Granuflex Extra Thin experienced less pain (P < 0.001), required less analgesia (P = 0.0154) and were able to carry out their normal daily activities including bathing or showering without affecting the dressing or the wound. Patient satisfaction with the new dressing appeared to be very high especially in those patients who pursued an active lifestyle. PMID:7894807

  6. Novel biodegradable composite wound dressings with controlled release of antibiotics: results in a guinea pig burn model.

    PubMed

    Elsner, Jonathan J; Egozi, Dana; Ullmann, Yehuda; Berdicevsky, Israela; Shefy-Peleg, Adaya; Zilberman, Meital

    2011-08-01

    Approximately 70% of all people with severe burns die from related infections despite advances in treatment regimens and the best efforts of nurses and doctors. Silver ion-eluting wound dressings are available for overcoming this problem. However, there are reports of deleterious effects of such dressings due to cellular toxicity that delays the healing process, and the dressing changes needed 1-2 times a day are uncomfortable for the patient and time consuming for the stuff. An alternative concept in wound dressing design that combines the advantages of occlusive dressings with biodegradability and intrinsic topical antibiotic treatment is described herewith. The new composite structure presented in this article is based on a polyglyconate mesh and a porous poly-(dl-lactic-co-glycolic acid) matrix loaded with gentamicin developed to provide controlled release of antibiotics for three weeks. In vivo evaluation of the dressing material in contaminated deep second degree burn wounds in guinea pigs (n=20) demonstrated its ability to accelerate epithelialization by 40% compared to an unloaded format of the material and a conventional dressing material. Wound contraction was reduced significantly, and a better quality scar tissue was formed. The current dressing material exhibits promising results, does not require frequent bandage changes, and offers a potentially valuable and economic approach to treating the life-threatening complication of burn-related infections. Copyright © 2011 Elsevier Ltd and ISBI. All rights reserved.

  7. Release of antibiotics from collagen dressing.

    PubMed

    Grzybowski, J; Antos-Bielska, M; Ołdak, E; Trafny, E A

    1997-01-01

    Our new collagen dressing has been developed recently. Three types (A, B, and C) of the dressing were prepared in this study. Each type contained bacitracin, neomycin or colistin. The antibiotic was input into: i. collagen sponge (CS)--type A, ii. layer of limited hydrophobicity (LLH)--type B, and iii. into both CS and LLH layers--type C. The final concentration of the antibiotic that resulted from the loading level was 2 mg/cm2 for the dressings of type A and B and 4 mg/cm2 for the dressing of type C. The antibiotics were then extracted from the pieces of dressings for two days through dialysis membrane. Susceptibility of 54 bacterial strains (S. aureus, P. aeruginosa, and Acinetobacter) isolated from burn wounds were tested to the three antibiotics used for preparation of the dressings. The results of the study evidenced that efficiency of released of antibiotics into the extracts depended on the kind of antibiotic and on the type of dressing. The concentration of the antibiotics proved to be much higher than MIC90 values of the bacterial isolates tested in respect to their susceptibility. The dressing containing mixture of the three antibiotics in two layers--CS and LLH is now considered as potentially effective for care of infected wounds. It may be useful for the treatment of infected wounds or for profilaxis of contaminated wounds, ensuring: i. sufficient antimicrobial activity in wound, and ii. optimal wound environment for the presence of collagenic biomaterial on the damaged tissue.

  8. A Modeling Approach to Fiber Fracture in Melt Impregnation

    NASA Astrophysics Data System (ADS)

    Ren, Feng; Zhang, Cong; Yu, Yang; Xin, Chunling; Tang, Ke; He, Yadong

    2017-02-01

    The effect of process variables such as roving pulling speed, melt temperature and number of pins on the fiber fracture during the processing of thermoplastic based composites was investigated in this study. The melt impregnation was used in this process of continuous glass fiber reinforced thermoplastic composites. Previous investigators have suggested a variety of models for melt impregnation, while comparatively little effort has been spent on modeling the fiber fracture caused by the viscous resin. Herein, a mathematical model was developed for impregnation process to predict the fiber fracture rate and describe the experimental results with the Weibull intensity distribution function. The optimal parameters of this process were obtained by orthogonal experiment. The results suggest that the fiber fracture is caused by viscous shear stress on fiber bundle in melt impregnation mold when pulling the fiber bundle.

  9. Positive and negative impacts of specialty malts on beer foam: a comparison of various cereal products for their foaming properties.

    PubMed

    Combe, Alexander L; Ang, Justin K; Bamforth, Charles W

    2013-07-01

    The foam stability of beer is dependent on the presence of foam-stabilizing polypeptides derived from the cereals from which it is made. It has long been argued that there is a tendency to boost the foam-stabilizing capabilities of these polypeptides at the heating stages involved in the production of the grist materials. The present study started with the intent to confirm whether these changes occurred and to assess the extent to which different cereal products differed in their foam-stabilizing tendencies. Cereal products differ enormously in their foam-stabilizing capabilities. Heavily roasted grains, notably black malt and roast barley, do have superior foaming properties. However, certain specialty malts, notably crystal malts, display inferior foam performance. The observed foaming pattern is a balance between their content of foam-positive and foam-negative components. Products such as pale malt do contain foam-negative materials but have a net balance in favour of foam-stabilizing entities. By contrast, wheat malt and especially black malt have a heavy preponderance of foam-positive components. Crystal malt displays the converse behaviour: it contains low-molecular-weight foam-negative species. Several of the cereal products appear to contain higher-molecular-weight foam inhibitors, but it appears that they are merely species that are of inherently inferior foam-stabilizing capability to the foaming polypeptides from egg white that were employed to probe the system. The foam-damaging species derived from crystal malt carried through to beers brewed from them. Intense heating in the production of cereal products does lead to enhanced foam performance in extracts of those products. However, not all speciality malts display superior foam performance, through their development of foam-negative species of lower molecular weight. © 2013 Society of Chemical Industry.

  10. Bi-Layer Wound Dressing System for Combat Casualty Care

    DTIC Science & Technology

    2004-09-01

    C. Bonacorsi, M.S.G. Raddi, and I.Z. Carlos. 2004. Cytotoxicity of chlorhexidine digluconate to murine macrophages and its effect on hydrogen...chlorexhidine digluconate or 1 % chloramphenicol, as described previously. Each experimental dressing was then covered with a piece of sterile parafilm...chloramphenicol-loaded dressings were 2-log lower for the first 24 h than when applying the chlorhexidine -loaded dressings (Figure 2). However, there was no

  11. Influence of dressing application time after breast augmentation on cutaneous colonization: A randomized clinical trial.

    PubMed

    Mendes, D A; Veiga, D F; Veiga-Filho, J; Loyola, A B A T; Paiva, L F; Novo, N F; Sabino-Neto, M; Ferreira, L M

    2018-06-01

    Concepts regarding the best way to treat a surgical wound vary, in literature, ranging from no dressing use to dressing maintenance for 24 to 48 hours or until suture removal. This study aimed to evaluate the influence of the length of dressing maintenance after breast augmentation with implants on cutaneous colonization and surgical site infection. This is a two-arm, parallel group, randomized clinical trial. Eighty patients who were candidates for augmentation mammoplasty with silicone implants were randomly allocated to two groups, in which the dressing was removed on postoperative day 1 (group A, n = 40) or postoperative day 6 (group B, n = 40). Cutaneous colonization was examined by culturing samples collected before and after dressing removal. The criteria defined by the Centers for Disease Control and Prevention were used to assess surgical site infection. No significant difference regarding cutaneous colonization was observed between groups before dressing application. On postoperative day 6, significantly more bacterial growth was observed in group A (p = 0.01). No surgical site infection occurred. We concluded that maintaining the dressing for 6 days led to a lower cutaneous colonization but did not influence surgical site infection rates. Copyright © 2018 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. The clinical and cost effectiveness of bee honey dressing in the treatment of diabetic foot ulcers.

    PubMed

    Moghazy, A M; Shams, M E; Adly, O A; Abbas, A H; El-Badawy, M A; Elsakka, D M; Hassan, S A; Abdelmohsen, W S; Ali, O S; Mohamed, B A

    2010-09-01

    Honey is known, since antiquity, as an effective wound dressing. Emergence of resistant strains and the financial burden of modern dressings, have revived honey as cost-effective dressing particularly in developing countries. Its suitability for all stages of wound healing suggests its clinical effectiveness in diabetic foot wound infections. Thirty infected diabetic foot wounds were randomly selected from patients presenting to Surgery Department, Suez Canal University Hospital, Ismailia, Egypt. Honey dressing was applied to wounds for 3 months till healing, grafting or failure of treatment. Changes in grade and stage of wounds, using University of Texas Diabetic Wound Classification, as well as surface area were recorded weekly. Bacterial load was determined before and after honey dressing. Complete healing was significantly achieved in 43.3% of ulcers. Decrease in size and healthy granulation was significantly observed in another 43.3% of patients. Bacterial load of all ulcers was significantly reduced after the first week of honey dressing. Failure of treatment was observed in 6.7% of ulcers. This study proves that commercial clover honey is a clinical and cost-effective dressing for diabetic wound in developing countries. It is omnipresence and concordance with cultural beliefs makes it a typical environmentally based method for treating these conditions. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  13. A wearable wound moisture sensor as an indicator for wound dressing change: an observational study of wound moisture and status.

    PubMed

    Milne, Stephen D; Seoudi, Ihab; Al Hamad, Hanadi; Talal, Talal K; Anoop, Anzila A; Allahverdi, Niloofar; Zakaria, Zain; Menzies, Robert; Connolly, Patricia

    2016-12-01

    Wound moisture is known to be a key parameter to ensure optimum healing conditions in wound care. This study tests the moisture content of wounds in normal practice in order to observe the moisture condition of the wound at the point of dressing change. This study is also the first large-scale observational study that investigates wound moisture status at dressing change. The WoundSense sensor is a commercially available moisture sensor which sits directly on the wound in order to find the moisture status of the wound without disturbing or removing the dressing. The results show that of the 588 dressing changes recorded, 44·9% were made when the moisture reading was in the optimum moisture zone. Of the 30 patients recruited for this study, 11 patients had an optimum moisture reading for at least 50% of the measurements before dressing change. These results suggest that a large number of unnecessary dressing changes are being made. This is a significant finding of the study as it suggests that the protocols currently followed can be modified to allow fewer dressing changes and less disturbance of the healing wound bed. © 2015 The Authors. International Wound Journal published by Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  14. Seeing "the Dress" in the Right Light: Perceived Colors and Inferred Light Sources.

    PubMed

    Chetverikov, Andrey; Ivanchei, Ivan

    2016-08-01

    In the well-known "dress" photograph, people either see the dress as blue with black stripes or as white with golden stripes. We suggest that the perception of colors is guided by the scene interpretation and the inferred positions of light sources. We tested this hypothesis in two online studies using color matching to estimate the colors observers see, while controlling for individual differences in gray point bias and color discrimination. Study 1 demonstrates that the interpretation of the dress corresponds to differences in perceived colors. Moreover, people who perceive the dress as blue-and-black are two times more likely to consider the light source as frontal, than those who see the white-and-gold dress. The inferred light sources, in turn, depend on the circadian changes in ambient light. The interpretation of the scene background as a wall or a mirror is consistent with the perceived colors as well. Study 2 shows that matching provides reliable results on differing devices and replicates the findings on scene interpretation and light sources. Additionally, we show that participants' environmental lighting conditions are an important cue for perceiving the dress colors. The exact mechanisms of how environmental lighting and circadian changes influence the perceived colors of the dress deserve further investigation.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ozmen, Ozcan; Zondlo, John W.; Lee, Shiwoo

    A bio-inspired surfactant was utilized to assist in the efficient impregnation of a nano-CeO₂ catalyst throughout both porous Solid Oxide Fuel Cells (SOFC’s) electrodes simultaneously. The process included the initial modification of electrode pore walls with a polydopamine film. The cell was then submersed into a cerium salt solution. The amount of nano-CeO₂ deposited per impregnation step increased by 3.5 times by utilizing this two-step protocol in comparison to a conventional drip impregnation method. The impregnated cells exhibited a 20% higher power density than a baseline cell without the nano-catalyst at 750°C (using humid H₂ fuel).

  16. Technics study on high accuracy crush dressing and sharpening of diamond grinding wheel

    NASA Astrophysics Data System (ADS)

    Jia, Yunhai; Lu, Xuejun; Li, Jiangang; Zhu, Lixin; Song, Yingjie

    2011-05-01

    Mechanical grinding of artificial diamond grinding wheel was traditional wheel dressing process. The rotate speed and infeed depth of tool wheel were main technics parameters. The suitable technics parameters of metals-bonded diamond grinding wheel and resin-bonded diamond grinding wheel high accuracy crush dressing were obtained by a mount of experiment in super-hard material wheel dressing grind machine and by analysis of grinding force. In the same time, the effect of machine sharpening and sprinkle granule sharpening was contrasted. These analyses and lots of experiments had extent instruction significance to artificial diamond grinding wheel accuracy crush dressing.

  17. Tiny patients, tiny dressings: a guide to the neonatal PICC dressing change.

    PubMed

    Sharpe, Elizabeth L

    2008-06-01

    Advances in neonatology now support the survival of the tiniest of infants. The peripherally inserted central catheter (PICC) has now become an integral part of routine practice in neonatal intensive care units around the world. Keen attention to safe maintenance of these devices is essential. A properly applied and maintained PICC dressing is the first line of defense to minimize the risk of complications such as dislodgement, migration, and infection. This article describes a neonatal PICC dressing change and discusses the frequently encountered quandaries surrounding this important procedure, including dressing materials, frequency, site preparation, barrier precautions, and other relevant concerns.

  18. Constructing medical social authority on dress in Victorian Canada.

    PubMed

    O'Connor, Eileen

    2008-01-01

    During the late-Victorian period, campaigns to "reform" middle-class women's dress were grounded in discourses on health, eugenics, declining birth rates, comfort, and aesthetics. In Britain, the United States and Germany, organized "dress reform" movements emerged in the latter half of the 19th century, while in Canada the campaign was led primarily by physicians through public health education. This article explores the discussion on women's dress in public health literature in Canadian circulation between 1860-1900 and interprets findings within a feminist poststructuralist framework that posits the understanding of women's bodies and gender regulation to be central to knowledge construction on women's dress.

  19. High temperature in-situ synchrotron-based XRD study on the crystal structure evolution of C/C composite impregnated by FLiNaK molten salt.

    PubMed

    Feng, Shanglei; Yang, Yingguo; Li, Li; Zhang, Dongsheng; Yang, Xinmei; Xia, Huihao; Yan, Long; Tsang, Derek K L; Huai, Ping; Zhou, Xingtai

    2017-09-06

    An in-situ real-time synchrotron-based grazing incidence X-ray diffraction was systematically used to investigate the crystal structural evolution of carbon fiber reinforced carbon matrix (C/C) composite impregnated with FLiNaK molten salt during the heat-treatment process. It was found that the crystallographic thermal expansion and contraction rate of interlayer spacing d 002 in C/C composite with FLiNaK salt impregnation is smaller than that in the virgin sample, indicating the suppression on interlayer spacing from FLiNaK salt impregnated. Meanwhile the crystallite size L C002 of C/C composite with FLiNaK salt impregnation is larger than the virgin one after whole heat treatment process, indicating that FLiNaK salt impregnation could facilitate the crystallization of C/C composite after heat treatment process. This improved crystallization in C/C composite with FLiNaK salt impregnation suggests the synthetic action of the salt squeeze effect on crooked carbon layer and the release of internal residual stress after heating-cooling process. Thus, the present study not only contribute to reveal the interaction mechanism between C/C composite and FLiNaK salt in high temperature environment, but also promote the design of safer and more reliable C/C composite materials for the next generation molten salt reactor.

  20. State-of-the-Art Review on the Characteristics of Surfactants and Foam from Foam Concrete Perspective

    NASA Astrophysics Data System (ADS)

    Sahu, Sritam Swapnadarshi; Gandhi, Indu Siva Ranjani; Khwairakpam, Selija

    2018-06-01

    Foam concrete finds application in many areas, generally as a function of its relatively lightweight and its beneficial properties in terms of reduction in dead load on structure, excellent thermal insulation and contribution to energy conservation. For production of foam concrete with desired properties, stable and good quality foam is the key requirement. It is to be noted that the selection of surfactant and foam production parameters play a vital role in the properties of foam which in turn affects the properties of foam concrete. However, the literature available on the influence of characteristics of foaming agent and foam on the properties of foam concrete are rather limited. Hence, a more systematic research is needed in this direction. The focus of this work is to provide a review on characteristics of surfactant (foaming agent) and foam for use in foam concrete production.

  1. State-of-the-Art Review on the Characteristics of Surfactants and Foam from Foam Concrete Perspective

    NASA Astrophysics Data System (ADS)

    Sahu, Sritam Swapnadarshi; Gandhi, Indu Siva Ranjani; Khwairakpam, Selija

    2018-02-01

    Foam concrete finds application in many areas, generally as a function of its relatively lightweight and its beneficial properties in terms of reduction in dead load on structure, excellent thermal insulation and contribution to energy conservation. For production of foam concrete with desired properties, stable and good quality foam is the key requirement. It is to be noted that the selection of surfactant and foam production parameters play a vital role in the properties of foam which in turn affects the properties of foam concrete. However, the literature available on the influence of characteristics of foaming agent and foam on the properties of foam concrete are rather limited. Hence, a more systematic research is needed in this direction. The focus of this work is to provide a review on characteristics of surfactant (foaming agent) and foam for use in foam concrete production.

  2. Association of Alpha Tocopherol and Ag Sulfadiazine Chitosan Oleate Nanocarriers in Bioactive Dressings Supporting Platelet Lysate Application to Skin Wounds.

    PubMed

    Bonferoni, Maria Cristina; Sandri, Giuseppina; Rossi, Silvia; Dellera, Eleonora; Invernizzi, Alessandro; Boselli, Cinzia; Cornaglia, Antonia Icaro; Del Fante, Claudia; Perotti, Cesare; Vigani, Barbara; Riva, Federica; Caramella, Carla; Ferrari, Franca

    2018-02-09

    Chitosan oleate was previously proposed to encapsulate in nanocarriers some poorly soluble molecules aimed to wound therapy, such as the anti-infective silver sulfadiazine, and the antioxidant α tocopherol. Because nanocarriers need a suitable formulation to be administered to wounds, in the present paper, these previously developed nanocarriers were loaded into freeze dried dressings based on chitosan glutamate. These were proposed as bioactive dressings aimed to support the application to wounds of platelet lysate, a hemoderivative rich in growth factors. The dressings were characterized for hydration capacity, morphological aspect, and rheological and mechanical behavior. Although chitosan oleate nanocarriers clearly decreased the mechanical properties of dressings, these remained compatible with handling and application to wounds. Preliminary studies in vitro on fibroblast cell cultures demonstrated good compatibility of platelet lysate with nanocarriers and bioactive dressings. An in vivo study on a murine wound model showed an accelerating wound healing effect for the bioactive dressing and its suitability as support of the platelet lysate application to wounds.

  3. Association of Alpha Tocopherol and Ag Sulfadiazine Chitosan Oleate Nanocarriers in Bioactive Dressings Supporting Platelet Lysate Application to Skin Wounds

    PubMed Central

    Bonferoni, Maria Cristina; Dellera, Eleonora; Invernizzi, Alessandro; Cornaglia, Antonia Icaro; Perotti, Cesare; Vigani, Barbara; Caramella, Carla; Ferrari, Franca

    2018-01-01

    Chitosan oleate was previously proposed to encapsulate in nanocarriers some poorly soluble molecules aimed to wound therapy, such as the anti-infective silver sulfadiazine, and the antioxidant α tocopherol. Because nanocarriers need a suitable formulation to be administered to wounds, in the present paper, these previously developed nanocarriers were loaded into freeze dried dressings based on chitosan glutamate. These were proposed as bioactive dressings aimed to support the application to wounds of platelet lysate, a hemoderivative rich in growth factors. The dressings were characterized for hydration capacity, morphological aspect, and rheological and mechanical behavior. Although chitosan oleate nanocarriers clearly decreased the mechanical properties of dressings, these remained compatible with handling and application to wounds. Preliminary studies in vitro on fibroblast cell cultures demonstrated good compatibility of platelet lysate with nanocarriers and bioactive dressings. An in vivo study on a murine wound model showed an accelerating wound healing effect for the bioactive dressing and its suitability as support of the platelet lysate application to wounds. PMID:29425164

  4. Groin dressing after cardiac catheterization. Comparison between light dressing with thin transparent tape (Tegaderm) and conventional tight/pressure dressing with an elastic adhesive bandage (Tensoplast).

    PubMed

    Boonbaichaiyapruck, S; Hutayanon, P; Chanthanamatta, P; Dumrongwatana, T; Intarayotha, N; Krisdee, V; Yamvong, S

    2001-12-01

    Post cardiac catheterization puncture site care is usually done with a tight pressure dressing by an elastic adhesive bandage (Tensoplast) due to the belief that it should prevent bleeding. The practice is uncomfortable to the patients. The authors compared a new way of dressing using light transparent tape (Tegaderm) to the conventional tight pressure one. 126 post coronary angiography patients were randomized to have their groins dressed either with Tensoplast or with Tegaderm. Patients ambulated 8 hours after the procedures. The groin was evaluated for pain, discomfort and bleeding complications. 49 per cent in the Tensoplast vs 26.9 per cent in the Tegaderm group experienced pain (p value of 0.01). 55.5 per cent in the Tensoplast group vs 11.1 per cent in the Tegaderm group reported discomfort. 4.7 per cent in the Tensoplast vs 1.6 per cent in the Tegaderm group developed bleeding or hematoma. Dressing of the puncture site after cardiac catheterization with Tegaderm was more comfortable than the conventional Tensoplast without any difference in bleeding complications.

  5. Effects of honey and sugar dressings on wound healing.

    PubMed

    Mphande, A N G; Killowe, C; Phalira, S; Jones, H Wynn; Harrison, W J

    2007-07-01

    To investigate whether there is a difference between the efficacy of honey and sugar as wound dressings. Patients with open or infected wounds were randomised to receive either honey or sugar dressings. Bacterial colonisation, wound size, wound ASEPSIS score and pain were assessed at the start of treatment and at weekly intervals until full healing occurred. Forty patients were enrolled; 18 received sugar dressings and 22 honey dressings. In the honey group, 55% of patients had positive wound cultures at the start of treatment and 23% at one week, compared with 52% and 39% respectively in the sugar group.The median rate of healing in the first two weeks of treatment was 3.8cm2/week for the honey group and 2.2cm2/week for the sugar group. After three weeks of treatment 86% of patients treated with honey had no pain during dressing changes, compared with 72% treated with sugar. Honey appears to be more effective than sugar in reducing bacterial contamination and promoting wound healing, and slightly less painful than sugar during dressing changes and motion.

  6. Using leptospermum honey to manage wounds impaired by radiotherapy: a case series.

    PubMed

    Robson, Val; Cooper, Rose

    2009-01-01

    Radiation-induced tissue injury and wounds with radiation-impaired healing are traumatic for patients and challenging for their caregivers. Standardized management approaches do not exist. The effect of Leptospermum honey as a primary dressing for managing these wounds was assessed in four patients (age range 63 to 93 years) who had previously undergone radiotherapy that left them with fragile friable areas of damaged skin that did not respond to conventional treatment. Compromised areas involved the neck, cheek, groin/perineum, and chest. In patients 1 and 2, after topical application of honey via hydrofiber rope and nonadhesive foam, respectively, improvements in the size and condition of wound/periwound area and a reduction in pain were noted before death or loss to follow-up. After including honey in the treatment regimen of patients 3 and 4, complete healing was noted in 2.5 weeks (with honey and paraffin) and 6 weeks (with honey-soaked hydrofiber rope), respectively. No adverse events were reported. Honey as an adjunct to conventional wound/skin care post radiation therapy shows promise for less painful healing in these chronic wounds. Prospective, randomized, controlled clinical studies are needed to confirm these observations.

  7. Experimental Study of Hysteresis behavior of Foam Generation in Porous Media.

    PubMed

    Kahrobaei, S; Vincent-Bonnieu, S; Farajzadeh, R

    2017-08-21

    Foam can be used for gas mobility control in different subsurface applications. The success of foam-injection process depends on foam-generation and propagation rate inside the porous medium. In some cases, foam properties depend on the history of the flow or concentration of the surfactant, i.e., the hysteresis effect. Foam may show hysteresis behavior by exhibiting multiple states at the same injection conditions, where coarse-textured foam is converted into strong foam with fine texture at a critical injection velocity or pressure gradient. This study aims to investigate the effects of injection velocity and surfactant concentration on foam generation and hysteresis behavior as a function of foam quality. We find that the transition from coarse-foam to strong-foam (i.e., the minimum pressure gradient for foam generation) is almost independent of flowrate, surfactant concentration, and foam quality. Moreover, the hysteresis behavior in foam generation occurs only at high-quality regimes and when the pressure gradient is below a certain value regardless of the total flow rate and surfactant concentration. We also observe that the rheological behavior of foam is strongly dependent on liquid velocity.

  8. Impregnating Coal With Calcium Carbonate

    NASA Technical Reports Server (NTRS)

    Sharma, Pramod K.; Voecks, Gerald E.; Gavalas, George R.

    1991-01-01

    Relatively inexpensive process proposed for impregnating coal with calcium carbonate to increase rates of gasification and combustion of coal and to reduce emission of sulfur by trapping sulfur in calcium sulfide. Process involves aqueous-phase reactions between carbon dioxide (contained within pore network of coal) and calcium acetate. Coal impregnated with CO2 by exposing it to CO2 at high pressure.

  9. Resin impregnation of cellulose nanofibril films facilitated by water swelling

    Treesearch

    Yan Qing; Ronald Sabo; Zhiyong Cai; Yiqiang Wu

    2013-01-01

    Flexible composite films were produced by impregnating aqueous phenol formaldehyde (PF) resin into water-swollen cellulose nanofibril (CNF) films. CNF films were prepared using a pressurized filtration method in combination with freeze drying. The freeze-dried films were swollen with water then impregnated with PF resin by soaking in aqueous resin solutions of varying...

  10. Impregnation of bio-oil from small diameter pine into wood for moisture resistance

    Treesearch

    Thomas J. Robinson; Brian K. Via; Oladiran Fasina; Sushil Adhikari; Emily Carter

    2011-01-01

    Wood pyrolysis oil consists of hundreds of complex compounds, many of which are phenolic-based and exhibit hydrophobic properties. Southern yellow pine was impregnated with a pyrolysis oil-based penetrant using both a high pressure and vacuum impregnation systems, with no significant differences in retention levels. Penetrant concentrations ranging from 5-50% pyrolysis...

  11. Modeling Study: Mechanism of Foam Propagation in Porous Media at Different Levels of Minimum Mobilization Pressure Gradient

    NASA Astrophysics Data System (ADS)

    Izadi, M.; Kam, S.

    2017-12-01

    Scope: Numerous laboratory and field tests revealed that foam can effectively control gas mobility and improve sweep efficiency in enhanced-oil-recovery and subsurface-remediation processes, if correctly designed. The objective of this study is to answer (i) how mechanistic foam model parameters can be determined by fitting lab experiments in a step-by-step manner; (ii) how different levels of mobilization pressure gradient for foam generation affects the fundamentals of foam propagation; and (iii) how foam propagation distance can be estimated in the subsurface. This study for the first time shows why, and by how much, supercritical CO2 foams are advantaged over other types of foams such as N2 foam. Methods: First of all, by borrowing experimental data existing in the literature, this study shows how to capture mechanistic foam model parameters. The model, then, is applied to a wide range of mobilization pressure gradient to represent different types of foams that have been applied in the field (Note that supercritical CO2 foams exhibit much lower mobilization pressure compared to other types of foams (N2, steam, air, etc.). Finally, the model and parameters are used to evaluate different types of foam injection scenarios in order to predict how far foams can propagate with what properties in the field condition. Results and Conclusions: The results show that (i) the presence of three different foam states (strong, weak, intermediate) as well as two different strong-foam flow regimes (high-quality and low-quality regimes) plays a key role in model fit and field-scale propagation prediction and (ii) the importance of complex non-Newtonian foam rheology should not be underestimated. More specifically, this study finds that (i) supercritical CO2 foams can propagate a few hundreds of feet easily, which is a few orders of magnitude higher than other foams such as N2 foams; (ii) for dry foams (or, strong foams in the high-quality regime), the higher gas fractions the less foams travel, while for wet foams (or, strong foams in the low-quality regime) the distance is not sensitive to gas fraction; and (iii) the higher injection rates (or pressures), the farther foams propagate (this effect is much more pronounced for dry foams).

  12. The brain's dress code: How The Dress allows to decode the neuronal pathway of an optical illusion.

    PubMed

    Schlaffke, Lara; Golisch, Anne; Haag, Lauren M; Lenz, Melanie; Heba, Stefanie; Lissek, Silke; Schmidt-Wilcke, Tobias; Eysel, Ulf T; Tegenthoff, Martin

    2015-12-01

    Optical illusions have broadened our understanding of the brain's role in visual perception. A modern day optical illusion emerged from a posted photo of a striped dress, which some perceived as white and gold and others as blue and black. Here we show, using functional magnetic resonance imaging (fMRI), that those who perceive The Dress as white/gold have higher activation in response to the image of The Dress in brain regions critically involved in higher cognition (frontal and parietal brain areas). These results are consistent with theories of top-down modulation and present a neural signature associated with the differences in perceiving The Dress as white/gold or blue/black. Furthermore the results support recent psychophysiological data on this phenomenon and provide a fundamental building block to study interindividual differences in visual processing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Electrospun polymeric dressings functionalized with antimicrobial peptides and collagen type I for enhanced wound healing

    NASA Astrophysics Data System (ADS)

    Felgueiras, H. P.; Amorim, M. T. P.

    2017-10-01

    Modern wound dressings combine medical textiles with active compounds that stimulate wound healing while protecting against infection. Electrospun wound dressings have been extensively studied and the electrospinning technique recognized as an efficient approach for the production of nanoscale fibrous mats. The unique diverse function and architecture of antimicrobial peptides (AMPs) has attracted considerable attention as a tool for the design of new anti-infective drugs. Functionalizing electrospun wound dressings with these AMPs is nowadays being researched. In the present work, we explore these new systems by highlighting the most important characteristics of electropsun wound dressings, revealing the importance of AMPs to wound healing, and the methods available to functionalize the electrospun mats with these molecules. The combined therapeutic potential of collagen type I and these AMP functionalized dressings will be highlighted as well; the significance of these new strategies for the future of wound healing will be clarified.

  14. The Evaluation of Foam Performance and Flooding Efficiency

    NASA Astrophysics Data System (ADS)

    Keliang, Wang; Yuhao, Chen; Gang, Wang; Gen, Li

    2017-12-01

    ROSS-Miles and spinning drop interfacial tensionmeter are used to select suitable foam system through foam composite index (FCI) and interfacial tension (IT). The selected foam system are taken to conduct further test. The further tests are evaluating the foam system resistance to adsorption with multi-round core flooding dynamic adsorption test and evaluating the performance of foam system with four kinds of different transport distance, quantitatively analyzing the foam system effective distance after dynamic adsorption. The result shows that the foaming ability and the mobilizing ability of the foam system decrease with the increase of the round of dynamic adsorption. As the transport distance increases, the foaming ability and the mobilizing ability of the foam system decrease. This result further reveals the flooding characteristics of nitrogen foam flooding, which provides a reference for the implementation of nitrogen foam flooding technology.

  15. Electrochemically triggered release of acetylcholine from scCO2 impregnated conductive polymer films evokes intracellular Ca2+ signaling in neurotypic SH-SY5Y cells.

    PubMed

    Löffler, Susanne; Seyock, Silke; Nybom, Rolf; Jacobson, Gunilla B; Richter-Dahlfors, Agneta

    2016-12-10

    Implantable devices for electronically triggered drug release are attractive to achieve spatial and temporal control over drug concentrations in patients. Realization of such devices is, however, associated with technical and biological challenges. Among these are containment of drug reservoirs, lack of precise control cues, as well as the charge and size of the drug. Here, we present a method for electronically triggered release of the quaternary ammonium cation acetylcholine (ACh) from an impregnated conductive polymer film. Using supercritical carbon dioxide (scCO 2 ), a film of PEDOT/PSS (poly(3,4)-ethylenedioxythiophene doped with poly(styrenesulfonate)) is impregnated with the neurotransmitter acetylcholine. The gentle scCO 2 process generated a dry, drug-impregnated surface, well suited for interaction with biological material, while maintaining normal electrochemical properties of the polymer. Electrochemical switching of impregnated PEDOT/PSS films stimulated release of ACh from the polymer matrix, likely due to swelling mediated by the influx and efflux of charged and solvated ions. Triggered release of ACh did not affect the biological activity of the drug. This was shown by real-time monitoring of intracellular Ca 2+ signaling in neurotypic cells growing on the impregnated polymer surface. Collectively, scCO 2 impregnation of conducting polymers offers the first one-step, dopant-independent drug impregnation process, potentially facilitating loading of both anionic and cationic drugs that can be dissolved in scCO2 on its own or by using a co-solvent. We foresee that scCO 2 -loaded devices for electronically triggered drug release will create novel opportunities when generating active bio-coatings, tunable for specific needs, in a variety of medical settings. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Bacterial adhesion forces to Ag-impregnated contact lens cases and transmission to contact lenses.

    PubMed

    Qu, Wenwen; Busscher, Henk J; van der Mei, Henny C; Hooymans, Johanna M M

    2013-03-01

    To measure adhesion forces of Pseudomonas aeruginosa, Staphylococcus aureus, and Serratia marcescens to a rigid contact lens (CL), standard polypropylene, and Ag-impregnated lens cases using atomic force microscopy and determine bacterial transmission from lens case to CL. Adhesion forces of bacterial strains to Ag-impregnated and polypropylene lens cases and a rigid CL were measured using atomic force microscopy. Adhesion forces were used to calculate Weibull distributions, from which transmission probabilities from lens case to CL were derived. Transmission probabilities were compared with actual transmission of viable bacteria from a lens case to the CL in 0.9% NaCl and in an antimicrobial lens care solution. Bacterial transmission probabilities from polypropylene lens cases based on force analysis coincided well for all strains with actual transmission in 0.9% NaCl. Bacterial adhesion forces on Ag-impregnated lens cases were much smaller than that on polypropylene and CLs, yielding a high probability of transmission. Comparison with actual bacterial transmission indicated bacterial killing due to Ag ions during colony-forming unit transmission from an Ag-impregnated lens case, especially for P. aeruginosa. Transmission of viable bacteria from Ag-impregnated lens cases could be further decreased by use of an antimicrobial lens care solution instead of 0.9% NaCl. Bacterial transmission probabilities are higher from Ag-impregnated lens cases than from polypropylene lens cases because of small adhesion forces, but this is compensated for by enhanced bacterial killing due to Ag impregnation, especially when in combination with an antimicrobial lens care solution. This calls for a balanced combination of antimicrobial lens care solutions and surface properties of a lens case and CL.

  17. Impregnation of soft biological specimens with thermosetting resins and elastomers.

    PubMed

    von Hagens, G

    1979-06-01

    A new method for impregnation of biological specimens with thermosetting resins and elastomers is described. The method has the advantage that the original relief of the surface is retained. The impregnation is carried out by utilizing the difference between the high vapor tension of the intermedium (e.g., methylene chloride) and the low vapor tension of the solution to be polymerized. After impregnation, the specimen is subject to polymerization conditions without surrounding embedding material. The optical and mechanical properties can be selected by proper choice from various kinds of resins and different procedures, for example, by complete or incomplete impregnation. Acrylic resins, polyester resins, epoxy resins, polyurethanes and silicone rubber have been found suitable for the method. Excellent results have been obtained using transparent silicone rubber since after treatment the specimens are still flexible and resilient, and have retained their natural appearance.

  18. [Split-thickness skin graft donor site: which dressing use?].

    PubMed

    Caliot, J; Bodin, F; Chiriac, S; Correia, N; Poli-Mérol, M-L; François-Fiquet, C

    2015-04-01

    The management of split-thickness skin graft donor sites is targeted towards promoting the healing process, reducing pain. This has been an inconclusive topic. The aim of this study was to list and to discuss the French practices in term of split-thickness skin graft (STSG) donor site dressing. Multicentric national study by questionnaire (Google Drive(®)) for the attention of the plastic and/or pediatric surgeons. The type of dressing used on skin and sclap and the rhythm of dressing changes were analyzed. The study included 26 surgical centers on 40 contacted. The alginate is mainly used (Algostéril(®)) (17/26). It is left in position until healing (13/17). Five other types of dressings have been reported: paraffin gauze (3/26), lipidocolloides (1/26), Mepitel(®) (1/26), Mepilex(®) (1/26), indifferent use of gauze or alginate dressings (4/26). Twenty-two out of 26 centers make no difference in dressing choice between skin and scalp. Medical practices did not differ between adult or pediatric departments. Cost-effectiveness has become an important issue in wound management, requiring judicious use. The lack of consensus regarding split-thickness skin graft donor site dressing and our clinical practices force us to reconsider the best therapeutic option. This study coupled with the analysis of the literature highlights the difficulties of the practitioner in choosing the best dressing. The alginate seems to get the preference of our practices by its ease of use, its absence of change (reduces pain by limiting manipulations) and its moderate cost. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  19. A comparison of an antibacterial sandwich dressing vs dressing containing silver.

    PubMed

    Krasowski, Grzegorz; Jawień, Arkadiusz; Tukiendorf, Andrzej; Rybak, Zbigniew; Junka, Adam; Olejniczak-Nowakowska, Małgorzata; Bartoszewicz, Marzenna; Smutnicka, Danuta

    2015-01-01

    The purpose of this study was to compare the efficacy of dressings containing octenidine vs. dressings containing silver in the wound healing in the course of a chronic venous disease. There were two groups of 40 patients who met the inclusion criteria and who did not meet the exclusion criteria. The patients were randomly assigned into the groups (envelope method). The first, "O group" was treated with octenidine-based dressings. The second, "S group" was treated with silver dressings. The study lasted for 56 days. All patients in the research were treated with medical compression stockings with cotton understockings. Microbiological eradication was observed on the 28th day of the study among 33% of patients in the treatment group vs. 6% in control group. On the 56th day of the treatment, these percentages equalled 72% and 35%. The rate of healing was faster in the 0 group than in the S group. In the wounds <10 cm(2) it was faster by 1.35 cm(2)/week and in wounds >10 cm(2) it equalled 3.44 cm(2). The reduction of pain level was 37.5% higher in the O group, in contrast with the S group. One change of a dressing in the O group led to a 0.06 cm(2) greater wound size reduction and in the case of wounds >10 cm(2) to 0.29 cm(2) reduction compared with the S group. The presented results indicate that the efficacy of dressings containing octenidine is higher compared to silver dressings. © 2015 by the Wound Healing Society.

  20. Organic pollutant loading and biodegradability of firefighting foam

    NASA Astrophysics Data System (ADS)

    Zhang, Xian-Zhong; Bao, Zhi-ming; Hu, Cheng; Li-Shuai, Jing; Chen, Yang

    2017-11-01

    Firefighting foam has been widely used as the high-performance extinguishing agent in extinguishing the liquid poor fire. It was concerned for its environmental impacts due to its massive usage. In this study, the organic loading level and the biodegradability of 18 firefighting foams commonly used in China were evaluated and compared. The COD and TOC of firefighting foam concentrates are extremely high. Furthermore, those of foam solutions are also much higher than regular wastewater. The COD/TOC ratio of synthetic foams are higher than protein foams. The 28-day biodegradation rates of 18 firefighting foams are all over 60%, indicating that they are all ready biodegradable. Protein foams (P, FP and FFFP) have the higher organic loading and lower 28-day biodegradation rates compared to the synthetic foams (Class A foam, AFFF and S). The short and long-term impact of protein foams on the environment are larger than synthetic foams.

  1. Modified wound dressing with phyto-nanostructured coating to prevent staphylococcal and pseudomonal biofilm development

    NASA Astrophysics Data System (ADS)

    Anghel, Ion; Holban, Alina Maria; Grumezescu, Alexandru Mihai; Andronescu, Ecaterina; Ficai, Anton; Anghel, Alina Georgiana; Maganu, Maria; Lazǎr, Veronica; Chifiriuc, Mariana Carmen

    2012-12-01

    This paper reports a newly fabricated nanophyto-modified wound dressing with microbicidal and anti-adherence properties. Nanofluid-based magnetite doped with eugenol or limonene was used to fabricate modified wound dressings. Nanostructure coated materials were characterized by TEM, XRD, and FT-IR. For the quantitative measurement of biofilm-embedded microbial cells, a culture-based method for viable cell count was used. The optimized textile dressing samples proved to be more resistant to staphylococcal and pseudomonal colonization and biofilm formation compared to the uncoated controls. The functionalized surfaces for wound dressing seems to be a very useful tool for the prevention of wound microbial contamination on viable tissues.

  2. Modified wound dressing with phyto-nanostructured coating to prevent staphylococcal and pseudomonal biofilm development

    PubMed Central

    2012-01-01

    This paper reports a newly fabricated nanophyto-modified wound dressing with microbicidal and anti-adherence properties. Nanofluid-based magnetite doped with eugenol or limonene was used to fabricate modified wound dressings. Nanostructure coated materials were characterized by TEM, XRD, and FT-IR. For the quantitative measurement of biofilm-embedded microbial cells, a culture-based method for viable cell count was used. The optimized textile dressing samples proved to be more resistant to staphylococcal and pseudomonal colonization and biofilm formation compared to the uncoated controls. The functionalized surfaces for wound dressing seems to be a very useful tool for the prevention of wound microbial contamination on viable tissues. PMID:23272823

  3. Modified wound dressing with phyto-nanostructured coating to prevent staphylococcal and pseudomonal biofilm development.

    PubMed

    Anghel, Ion; Holban, Alina Maria; Grumezescu, Alexandru Mihai; Andronescu, Ecaterina; Ficai, Anton; Anghel, Alina Georgiana; Maganu, Maria; Laz R, Veronica; Chifiriuc, Mariana Carmen

    2012-12-31

    This paper reports a newly fabricated nanophyto-modified wound dressing with microbicidal and anti-adherence properties. Nanofluid-based magnetite doped with eugenol or limonene was used to fabricate modified wound dressings. Nanostructure coated materials were characterized by TEM, XRD, and FT-IR. For the quantitative measurement of biofilm-embedded microbial cells, a culture-based method for viable cell count was used. The optimized textile dressing samples proved to be more resistant to staphylococcal and pseudomonal colonization and biofilm formation compared to the uncoated controls. The functionalized surfaces for wound dressing seems to be a very useful tool for the prevention of wound microbial contamination on viable tissues.

  4. Exploratory Development of an Ultrafast-Curing Wound Dressing

    DTIC Science & Technology

    1991-05-31

    mils thick: Formulation 2 and 5 .. 36 17. Elution Rates for the 30% Chlorhexidine Gluconate ADD’s at t=0 and Stored at the Temperature Extremes (400C...determined from the in vivo trials conducted earlier (9). The 6 mil thick dressing (Formulation 2) demonstrated effectiveness when tested on guinea pigs...This dressing released approximately 3000 micrograms/sq. cm. in 72 hours or about 64% of the 12 mil dressing tested for shelf stability (Figure 16

  5. Unravelling nocebo effect: the mediating effect of anxiety between anticipation and pain at wound dressing change.

    PubMed

    Woo, Kevin Y

    2015-07-01

    The purpose of this study was to examine the mediating effect of anxiety in the relationship between anticipation and pain in people with chronic wounds. Pain is common in people with chronic wounds. Anticipation or negative expectation of discomfort has been shown to have an augmenting effect on pain; also known as nocebo hyperalgesia. This was a cross-sectional study with repeated measures. Prior to dressing change, anticipatory pain level was evaluated by a 11-point numerical rating scale and anxiety by the Six-items State-Trait Anxiety Inventory (STAI-6). During wound dressing changes, pain was measured before dressing removal, at dressing removal, at cleansing and dressing application using the numerical scale. Analysis was completed based on the data from a convenience sample of 96 patients. Participants reported more pain at cleansing and dressing removal than baseline. High levels of anticipation, anxiety and pain at dressing change for wounds were related to heavy exudate and wound that were covered with necrotic tissue. Finally, the relationship between anticipation and pain perception was mediated by anxiety. Anticipation of pain triggers anxiety that can lead to increased pain. There is a need to incorporate evaluation of anxiety and personal expectations as part of comprehensive pain assessment. Clinicians should be aware of the impact of emotions and anticipation on overall pain experience. © 2015 John Wiley & Sons Ltd.

  6. Hydrogel-gauze dressing for moderate-to-severe atopic dermatitis: development and efficacy study on atopic dermatitis-like skin lesions in NC/Nga mice.

    PubMed

    Ng, Shiow-Fern; Lew, Pit-Chin; Sin, Yong-Boey

    2014-11-01

    Topical emollients are known to provide symptomatic relief for atopic dermatitis. In hospitals, wet-wrap therapy has been shown to benefit children with moderate-to-severe atopic dermatitis (AD), but the application of wet-wraps is tedious and time-consuming. Topical emollients have low residence time and often dry out easily. The aim of this work was to develop a hydrogel-gauze dressing that is not only easy to apply but also rehydrates and traps moisture to provide longer relief for AD patients. In this study, a prototype hydrogel-gauze dressing was developed with varying ratios of sodium carboxymethylcellulose (NaCMC) and propylene glycol. The hydrogel-gauze dressings were assessed based on the moisture vapor transmission rate, moisture absorption, mechanical properties and storage stability over three months. Then, the efficacy of the hydrogel-gauze dressing was compared to topical emollients using transgenic NC/Nga mice with AD-like lesions. The NaCMC hydrogel-gauze dressings significantly lowered transepidermal water loss, and the animals displayed a faster recovery, which indicates that hydrogel-gauze dressings can trap moisture more effectively and accelerate AD healing. Hence, we propose that hydrogel-gauze dressings can potentially become an alternative to wet-wrap therapy due to the ease of application and the higher efficacy compared to topical products.

  7. Single and Combined Effects of Pesticide Seed Dressings and Herbicides on Earthworms, Soil Microorganisms, and Litter Decomposition.

    PubMed

    Van Hoesel, Willem; Tiefenbacher, Alexandra; König, Nina; Dorn, Verena M; Hagenguth, Julia F; Prah, Urša; Widhalm, Theresia; Wiklicky, Viktoria; Koller, Robert; Bonkowski, Michael; Lagerlöf, Jan; Ratzenböck, Andreas; Zaller, Johann G

    2017-01-01

    Seed dressing, i.e., the treatment of crop seeds with insecticides and/or fungicides, aiming to protect seeds from pests and diseases, is widely used in conventional agriculture. During the growing season, those crop fields often receive additional broadband herbicide applications. However, despite this broad utilization, very little is known on potential side effects or interactions between these different pesticide classes on soil organisms. In a greenhouse pot experiment, we studied single and interactive effects of seed dressing of winter wheat ( Triticum aestivum L. var. Capo ) with neonicotinoid insecticides and/or strobilurin and triazolinthione fungicides and an additional one-time application of a glyphosate-based herbicide on the activity of earthworms, soil microorganisms, litter decomposition, and crop growth. To further address food-web interactions, earthworms were introduced to half of the experimental units as an additional experimental factor. Seed dressings significantly reduced the surface activity of earthworms with no difference whether insecticides or fungicides were used. Moreover, seed dressing effects on earthworm activity were intensified by herbicides (significant herbicide × seed dressing interaction). Neither seed dressings nor herbicide application affected litter decomposition, soil basal respiration, microbial biomass, or specific respiration. Seed dressing did also not affect wheat growth. We conclude that interactive effects on soil biota and processes of different pesticide classes should receive more attention in ecotoxicological research.

  8. Randomized controlled trial of care bundles with chlorhexidine dressing and advanced dressings to prevent catheter-related bloodstream infections in pediatric hematology-oncology patients.

    PubMed

    Gerçeker, Gülçin Özalp; Yardımcı, Figen; Aydınok, Yeşim

    2017-06-01

    To compare the effects of the care bundles including chlorhexidine dressing and advanced dressings on the catheter-related bloodstream infection (CRBSI) rates in pediatric hematology-oncology patients with central venous catheters (CVCs). Twenty-seven PHO patients were recruited to participate in a prospective, randomized study in Turkey. The researcher used care bundles with chlorhexidine dressing in the experimental group (n = 14), and care bundles with advanced dressings in the control group (n = 13). According to the study results, 28.6% of the patients in the experimental group had CRBSI, while this rate was 38.5% in the control group patients. The CRBSI rate in the experimental group was 3.9, and the control group had 4.4 per 1000 inpatient catheter days. There was no exit-site infection in the experimental group. However, the control group had 1.7 per 1000 inpatient catheter days. Even though there was no difference between the two groups in which the researcher implemented care bundles with chlorhexidine dressing and advanced dressings in terms of CRBSI development, there was reduction in the CRBSI rates thanks to the care bundle approach. It is possible to control the CRBSI rates using care bundles in pediatric hematology-oncology patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Experimental Comparison of Efficiency of First Aid Dressings in Burning White Phosphorus on Bacon Model.

    PubMed

    Witkowski, Wojciech; Surowiecka-Pastewka, Agnieszka; Biesaga, Magdalena; Gierczak, Tomasz

    2015-08-12

    The aim of this study was to determine effectiveness of first aid dressings in extinguishing burning white phosphorous (WP), eliminating WP pieces from the surface, inhibiting re-ignition on the model (fresh bacon covered with military uniform), and preventing from late re-ignition caused by persistent WP pieces. Burning WP was extinguished with several dressings: tactical Military Dressing (WJ10), wet gauze, 2 hydrocolloids, and 3 prototypes of hydrocolloids developed by the authors. All examined dressings were effective in extinguishing WP provided that the entire area of the burning substance was completely covered. Moist gauze was especially effective in extinguishing WP, and also removed and absorbed the majority of the WP mass, preventing deeper penetration of WP particles. The immediate re-ignition was observed when all the remaining examined dressings were removed from the bacon. A stream of water was dangerous, as it splashed and transferred pieces of WP around. Moist gauze placed on burning WP for approximately 3 min was most effective in extinguishing WP and removing most of the WP pieces. We recommend moist gauze, used once or twice, as the best primary means for WP elimination and preventing tissue penetration. As a dressing used for medical evacuation (MEDEVAC), or as a second step after complete removal of visible WP, innovative hydrocolloid or hydrogel dressings should be used.

  10. Experimental Comparison of Efficiency of First Aid Dressings in Burning White Phosphorus on Bacon Model

    PubMed Central

    Witkowski, Wojciech; Surowiecka-Pastewka, Agnieszka; Biesaga, Magdalena; Gierczak, Tomasz

    2015-01-01

    Background The aim of this study was to determine effectiveness of first aid dressings in extinguishing burning white phosphorous (WP), eliminating WP pieces from the surface, inhibiting re-ignition on the model (fresh bacon covered with military uniform), and preventing from late re-ignition caused by persistent WP pieces. Material/Methods Burning WP was extinguished with several dressings: tactical Military Dressing (WJ10), wet gauze, 2 hydrocolloids, and 3 prototypes of hydrocolloids developed by the authors. Results All examined dressings were effective in extinguishing WP provided that the entire area of the burning substance was completely covered. Moist gauze was especially effective in extinguishing WP, and also removed and absorbed the majority of the WP mass, preventing deeper penetration of WP particles. The immediate re-ignition was observed when all the remaining examined dressings were removed from the bacon. A stream of water was dangerous, as it splashed and transferred pieces of WP around. Conclusions Moist gauze placed on burning WP for approximately 3 min was most effective in extinguishing WP and removing most of the WP pieces. We recommend moist gauze, used once or twice, as the best primary means for WP elimination and preventing tissue penetration. As a dressing used for medical evacuation (MEDEVAC), or as a second step after complete removal of visible WP, innovative hydrocolloid or hydrogel dressings should be used. PMID:26264209

  11. IMPREGNATION OF GRAPHITE SPECIMENS USING THE FURFURYL ALCOHOL IMPREGNATION PROCESS. Project DRAGON

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martina, R.A.; Vohler, O.J.

    1964-11-15

    This report gives the results of the furfuryl alcohol impregnation treatment of graphite fuel rods and end plugs done by Sigri Kohlefabrikate GmbH, Meitingen, from May 1962 till April 1964. By impregnating the components two and three times, resp. the permeability was decreased, starting from a coefficient of about 5 x 10{sup -2}cm{sup 2}sec{sup -1}, to a value of 10{sup -6} - 10{sup -7}cm{sup 2}sec{sup -1}. The rejects as occured with the first batches were finally diminished to a negligible amount by studying the single steps of treatment. (auth)

  12. Degradation free epoxy impregnation of REBCO coils and cables

    NASA Astrophysics Data System (ADS)

    Barth, C.; Bagrets, N.; Weiss, K.-P.; Bayer, C. M.; Bast, T.

    2013-05-01

    In applications utilizing high-temperature superconductors (HTS) under high mechanical loads as high-field magnets or rotors of generators and motors, the rare-earth-barium-copper-oxide (REBCO) tapes have to be stabilized mechanically. This is achieved using support structures of structural materials and filling the voids in the support through the impregnation of the tapes. The impregnation prevents movement of the tapes and distributes mechanical loads evenly. With high mechanical strengths and low sensitivities to rapid temperature changes, epoxy resins are desired materials for the impregnation of superconductor tapes. However, a strong decrease of the current-carrying capabilities was observed in previous epoxy-impregnated REBCO coils. In this work the thermal expansion mismatches between epoxy resins and REBCO tapes are identified as the cause of these degradations. Fillers are used to reduce the thermal expansions of glues and resins. Mixtures with varying filler contents are analyzed systematically. Their thermal expansions and the corresponding degradations of short REBCO tape samples are measured. A mixture of epoxy resin and filler is found which allows degradation-free impregnation of REBCO tapes. This mixture is validated on a 1.2 m long 15 × 5 Roebel-assembled-coated-conductor (RACC) cable from Industrial Research Limited (IRL).

  13. Impregnation of Scots pine and beech with tannin solutions: effect of viscosity and wood anatomy in wood infiltration.

    PubMed

    Tondi, G; Thevenon, M F; Mies, B; Standfest, G; Petutschnigg, A; Wieland, S

    The impregnation process of Scots pine and beech samples with tannin solutions was investigated. The two materials involved in the process (impregnation solution and wood samples) are studied in depth. Viscosity of mimosa tannin solutions and the anatomical aspect of beech and Scots pine were analysed and correlated. The viscosity of tannin solutions presents a non-newtonian behaviour when its pH level increases, and in the case of addition of hexamine as a hardener, the crosslinking of the flavonoids turns out to be of great importance. During the impregnation of Scots pine ( Pinus sylvestris L.) and beech ( Fagus sylvatica L.), the liquid and solid uptakes were monitored while taking into consideration the different conditions of the impregnation process. This method allowed to identify the best conditions needed in order to get a successful preservative uptake for each wooden substrate. The penetration mechanism within the wood of both species was revealed with the aid of a microscopic analysis. Scots pine is impregnated through the tracheids in the longitudinal direction and through parenchyma rays in the radial direction, whereas in beech, the penetration occurs almost completely through longitudinal vessels.

  14. A systematic review on the efficiency of cerium-impregnated activated carbons for the removal of gas-phase, elemental mercury from flue gas.

    PubMed

    Sowlat, Mohammad Hossein; Kakavandi, Babak; Lotfi, Saeedeh; Yunesian, Masud; Abdollahi, Mohammad; Rezaei Kalantary, Roshanak

    2017-05-01

    In the present systematic review, we aimed to collect and analyze all the relevant evidence on the efficiency of cerium-impregnated versus virgin-activated carbons (ACs) for the removal of gas-phase elemental mercury (Hg 0 ) from the flue gas of coal-fired power plants and to assess the effect of different calcination and operational parameters on their efficiency. A total of eight relevant papers (out of 1193 hits produced by the search) met the eligibility criteria and were included in the study. Results indicated that the Hg 0 adsorption capacity of cerium-impregnated ACs is significantly higher than that of virgin ACs, depending highly on the impregnation and operational parameters. It was noticed that although cerium-impregnated ACs possessed smaller surface areas and pore volumes, their Hg 0 removal efficiencies were still higher than their virgin counterparts. An increased Hg 0 removal efficiency was in general found by increasing the operational adsorption temperature as high as 150-170 °C. Studies also indicated that NO, SO 2 , and HCl have promoting impacts on the Hg 0 removal efficiency of Ce-impregnated ACs, while H 2 O has an inhibitory effect.

  15. Molecular dimensions and surface diffusion assisted mechanically robust slippery perfluoropolyether impregnated mesoporous alumina interfaces

    NASA Astrophysics Data System (ADS)

    Rowthu, Sriharitha; Balic, Edin E.; Hoffmann, Patrik

    2017-12-01

    Accomplishing mechanically robust omniphobic surfaces is a long-existing challenge, and can potentially find applications in bioengineering, tribology and paint industries. Slippery liquid impregnated mesoporous α-Al2O3 interfaces are achieved with water, alkanes, water based and oil based high viscosity acrylic paints. Incredibly high abrasion-resistance (wear coefficients ≤10-8 mm3 N-1 m-1) and ultra-low friction coefficients (≥0.025) are attained, attributing to the hard alumina matrix and continuous replenishment of perfluoropolyether aided by capillarity and surface diffusion processes. A variety of impregnating liquids employed suggest that large molecules, faster surface diffusion and lowest evaporation rate generate the rare combination of high wear-resistance and omniphobicity. It is noteworthy that these novel liquid impregnated Al2O3 composites exhibit outstanding load bearing capacity up to 350 MPa; three orders of magnitude higher than achievable by the state of the art omniphobic surfaces. Further, our developed thermodynamic calculations suggest that the relative thermodynamic stability of liquid impregnated composites is linearly proportional to the spreading coefficient (S) of the impregnating liquid with the matrix material and is an important tool for the selection of an appropriate matrix material for a given liquid.

  16. Supercritical impregnation of cinnamaldehyde into polylactic acid as a route to develop antibacterial food packaging materials.

    PubMed

    Villegas, Carolina; Torres, Alejandra; Rios, Mauricio; Rojas, Adrián; Romero, Julio; de Dicastillo, Carol López; Valenzuela, Ximena; Galotto, María José; Guarda, Abel

    2017-09-01

    Supercritical impregnation was used to incorporate a natural compound with antibacterial activity into biopolymer-based films to develop active food packaging materials. Impregnation tests were carried out under two pressure conditions (9 and 12MPa), and three depressurization rates (0.1, 1 and 10MPamin -1 ) in a high-pressure cell at a constant temperature equal to 40°C. Cinnamaldehyde (Ci), a natural compound with proven antimicrobial activity, was successfully incorporated into poly(lactic acid) films (PLA) using supercritical carbon dioxide (scCO 2 ), with impregnation yields ranging from 8 to 13% w/w. Higher pressure and slower depressurization rate seem to favor the Ci impregnation. The incorporation of Ci improved thermal, structural and mechanical properties of the PLA films. Impregnated films were more flexible, less brittle and more resistant materials than neat PLA films. The tested samples showed strong antibacterial activity against the selected microorganisms. In summary, this study provides an innovative route to the development of antibacterial biodegradable materials, which could be used in a wide range of applications of active food packaging. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Degradation of the performance of an epoxy-impregnated REBCO solenoid due to electromagnetic forces

    NASA Astrophysics Data System (ADS)

    Matsuda, T.; Okamura, T.; Hamada, M.; Matsumoto, S.; Ueno, T.; Piao, R.; Yanagisawa, Y.; Maeda, H.

    2018-03-01

    Recently, degradation of a high-field REBCO coil due to strong electromagnetic forces, has been identified. This issue is related to a conductor movement, forming a kink in the conductor body, and hence epoxy impregnation should be effective to prevent it. The purpose of this paper is to examine the effect of epoxy impregnation on the electromagnetic force-induced degradation of a REBCO coil. We made an epoxy impregnated solenoid coil and charged it at 4.2 K in an external field of 11 T. A notable characteristic behavior, which is different from that of a dry or paraffin impregnated coil, was observed in the coil's performance. The coil did not show any normal voltage below 408 A, at 65% on the coil load line, but it showed a sudden voltage jump at 408 A, resulted from a sudden fracture of the REBCO conductor. The outward bending, combined with a strong circumferential stress, caused the REBCO layer to fracture. Although epoxy impregnation is effective to suppress a conductor movement inside the winding, avoiding self-supported sites at a coil edge is required to eliminate degradation of the thin and flexible REBCO conductor.

  18. Development of the upper-body dressing scale for a buttoned shirt: a preliminary correlational study.

    PubMed

    Suzuki, Makoto; Yamada, Sumio; Omori, Mikayo; Hatakeyama, Mayumi; Sugimura, Yuko; Matsushita, Kazuhiko; Tagawa, Yoshikatsu

    2008-09-01

    A patient with poststroke hemiparesis learns to use the nonparetic arm to compensate for the weakness of the paretic arm to achieve independence in dressing. This is the learning process of new component actions on dressing. The purpose of this study was to develop the Upper-Body Dressing Scale (UBDS) for buttoned shirt dressing, which evaluates the component actions of upper-body dressing, and to provide preliminary data on internal consistency of the UBDS, as well as its reproducibility, validity, and sensitivity to clinical change. Correlational study of concurrent validity and reliability in which 63 consecutive stroke patients were enrolled in the study and were assessed repeatedly by the UBDS and the dressing item of Functional Independent Measure (FIM). Fifty-one patients completed the 3-wk study. The Cronbach's coefficient alpha of UBDS was 0.88. The principal component analysis extracted two components, which explained 62.3% of total variance. All items of the scale had high loading on the first component (0.65-0.83). Actions on the paralytic side were the positive loadings and actions on the healthy side were the negative loadings on the second component. Intraclass correlation coefficient was 0.87. The level of correlation between UBDS score and FIM dressing item scores was -0.72. Logistic regression analysis showed that only the score of UBDS on the first day of evaluation was a significant independent predictor of dressing ability (odds ratio, 0.82; 95% confidence interval, 0.71-0.95). The UBDS scores for paralytic hand passed into the sleeve, sleeve pulled up beyond the elbow joint, and sleeve pulled up beyond the shoulder joint were worse than the score for the other components of the task. These component actions had positive loading on the second component, which was identified by the principal component analysis. The UBDS has good internal consistency, reproducibility, validity, and sensitivity to clinical changes of patients with poststroke hemiparesis. This detailed UBDS assessment enables us to document the most difficult stages in dressing and to assess motor and process skills for independence of dressing.

  19. 8. SIDE VIEW OF NORTHEASTERN ROCKFACED DRESSED AND MORTARED STONE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. SIDE VIEW OF NORTHEASTERN ROCKFACED DRESSED AND MORTARED STONE BRIDGE ABUTMENT (LEFT) AND DRESSED, DRY-LAID RETAINING WALL (RIGHT). FACING WEST. - Coverts Crossing Bridge, Spanning Mahoning River along Township Route 372 (Covert Road), New Castle, Lawrence County, PA

  20. 10. SIDE VIEW OF SOUTHEASTERN ROCKFACED DRESSED AND MORTARED STONE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. SIDE VIEW OF SOUTHEASTERN ROCKFACED DRESSED AND MORTARED STONE BRIDGE ABUTMENT (RIGHT) AND DRESSED, DRY-LAID RETAINING WALL (LEFT). FACING NORTHWEST. - Coverts Crossing Bridge, Spanning Mahoning River along Township Route 372 (Covert Road), New Castle, Lawrence County, PA

  1. A.D.A.M. test (Antibiofilm Dressing's Activity Measurement) - Simple method for evaluating anti-biofilm activity of drug-saturated dressings against wound pathogens.

    PubMed

    Junka, Adam F; Żywicka, Anna; Szymczyk, Patrycja; Dziadas, Mariusz; Bartoszewicz, Marzena; Fijałkowski, Karol

    2017-12-01

    In the present article, we propose a simple Antibiofilm Dressing's Activity Measurement (A.D.A.M.) test that allows to check in vitro a dressing's suitability against biofilm-related wound infections. To perform the test, three agar discs are covered with biofilm formed by the tested pathogen after which they are assembled one over another in the form of an agar plug and placed in the well of a 24-well plate. The top disc is covered with the analyzed dressing and the entire set is incubated for 24h. During this time, the investigated antimicrobial substance is released from the dressing and penetrates to subsequent biofilm-covered agar discs. Biofilm reduction is measured using 2,3,5-triphenyl-2H-tetrazolium chloride (TTC) spectrometric assay and the results are compared to untreated control samples (agar plug covered with biofilm and without the dressing/or with a passive dressing placed on the top disc). Furthermore, in order to standardize the differences in penetrability of the drugs released from active dressings the results can be expressed as a dimensionless value referred to as the Penetrability Index. In summary, A.D.A.M. test is simple, cheap, can be performed practically in every clinical laboratory and takes no more time than routine microbiological diagnostics. Apart from measuring the released drug's activity, the A.D.A.M. test allows to assess drug penetrability (across three agar discs), reflecting real wound conditions, where microbes are frequently hidden under the necrotic tissue or cloth. In conclusion, the A.D.A.M. test produces a high volume of data that, when analyzed, can provide a researcher with a valuable hint concerning the applicability of active dressings against specific biofilm pathogens in a particular setting. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. The effectiveness of silver-releasing dressings in the management of non-healing chronic wounds: a meta-analysis.

    PubMed

    Lo, Shu-Fen; Chang, Chee-Jen; Hu, Wen-Yu; Hayter, Mark; Chang, Yu-Ting

    2009-03-01

    The purpose of this study was to examine the efficacy of silver-releasing dressings in the management of non-healing chronic wounds. Non-healing chronic wounds often have a negative physical impact on patients and place a financial burden on healthcare systems. Silver dressings are wound products designed to control infection and provide a wound environment conducive to healing. However, validation of the clinical efficacy of these dressings is lacking. Systematic review and meta-analysis. A systematic search of the major electronic databases PubMed, CINAHL, Cochrane, MEDLINE, British Nursing Index, EBSCO, OCLC and Proquest between 1950-June 2007 was conducted. Hand searches of selected periodicals, textbooks and checking reference lists and contacting experts was also performed. Eight studies were selected from a potentially relevant 1957 references screened. Analysis incorporated data from 1399 participants in the eight randomised control trials. We found that silver dressings significantly improved wound healing (CI(95): 0.16-0.39, p < 0.001), reduced odour (CI(95): 0.24-0.52, p < 0.001) and pain-related symptoms (CI(95): 0.18-0.47, p < 0.001), decreased wound exudates (CI(95): 0.17-0.44, p < 0.001) and had a prolonged dressing wear time (CI(95): 0.19-0.48, p = 0.028) when compared with alternative wound management approaches. An analysis of sensitivity in these studies by subgroup analysis generally supported these associations. Furthermore, studies indicated an improvement in quality of life (CI(95): 0.04-0.33, p = 0.013) using silver dressings in wound management with no associated severe adverse events. This meta-analysis confirms the effectiveness of silver dressings in wound healing and improving patients' quality of life. However, it also highlights the need for additional well-designed randomised controlled trials to evaluate the effectiveness of silver-related dressings further. The results of this study provide objective data on the effectiveness of silver-related dressing when applied to non-healing chronic wounds.

  3. On-machine precision preparation and dressing of ball-headed diamond wheel for the grinding of fused silica

    NASA Astrophysics Data System (ADS)

    Chen, Mingjun; Li, Ziang; Yu, Bo; Peng, Hui; Fang, Zhen

    2013-09-01

    In the grinding of high quality fused silica parts with complex surface or structure using ball-headed metal bonded diamond wheel with small diameter, the existing dressing methods are not suitable to dress the ball-headed diamond wheel precisely due to that they are either on-line in process dressing which may causes collision problem or without consideration for the effects of the tool setting error and electrode wear. An on-machine precision preparation and dressing method is proposed for ball-headed diamond wheel based on electrical discharge machining. By using this method the cylindrical diamond wheel with small diameter is manufactured to hemispherical-headed form. The obtained ball-headed diamond wheel is dressed after several grinding passes to recover geometrical accuracy and sharpness which is lost due to the wheel wear. A tool setting method based on high precision optical system is presented to reduce the wheel center setting error and dimension error. The effect of electrode tool wear is investigated by electrical dressing experiments, and the electrode tool wear compensation model is established based on the experimental results which show that the value of wear ratio coefficient K' tends to be constant with the increasing of the feed length of electrode and the mean value of K' is 0.156. Grinding experiments of fused silica are carried out on a test bench to evaluate the performance of the preparation and dressing method. The experimental results show that the surface roughness of the finished workpiece is 0.03 μm. The effect of the grinding parameter and dressing frequency on the surface roughness is investigated based on the measurement results of the surface roughness. This research provides an on-machine preparation and dressing method for ball-headed metal bonded diamond wheel used in the grinding of fused silica, which provides a solution to the tool setting method and the effect of electrode tool wear.

  4. Functional poly(ε-caprolactone)/chitosan dressings with nitric oxide-releasing property improve wound healing.

    PubMed

    Zhou, Xin; Wang, He; Zhang, Jimin; Li, Xuemei; Wu, Yifan; Wei, Yongzhen; Ji, Shenglu; Kong, Deling; Zhao, Qiang

    2017-05-01

    Wound healing dressings are increasingly needed clinically due to the large number of skin damage annually. Nitric oxide (NO) plays a key role in promoting wound healing, thus biomaterials with NO-releasing property receive increasing attention as ideal wound dressing. In present study, we prepared a novel functional wound dressing by combining electrospun poly(ε-caprolactone) (PCL) nonwoven mat with chitosan-based NO-releasing biomaterials (CS-NO). As-prepared PCL/CS-NO dressing released NO sustainably under the physiological conditions, which was controlled by the catalysis of β-galactosidase. In vivo wound healing characteristics were further evaluated on full-thickness cutaneous wounds in mice. Results showed that PCL/CS-NO wound dressings remarkably accelerated wound healing process through enhancing re-epithelialization and granulation formation and effectively improved the organization of regenerated tissues including epidermal-dermal junction, which could be ascribed to the pro-angiogenesis, immunomodulation, and enhanced collagen synthesis provided by the sustained release of NO. Therefore, PCL/CS-NO may be a promising candidate for wound dressings, especially for the chronic wound caused by the ischemia. Serious skin damage caused by trauma, surgery, burn or chronic disease has become one of the most serious clinical problems. Therefore, there is an increasing demand for ideal wound dressing that can improve wound healing. Due to the vital role of nitric oxide (NO), we developed a novel functional wound dressing by combining electrospun polycaprolactone (PCL) mat with NO-releasing biomaterial (CS-NO). The sustained release of NO from PCL/CS-NO demonstrated positive effects on wound healing, including pro-angiogenesis, immunomodulation, and enhanced collagen synthesis. Hence, wound healing process was remarkably accelerated and the organization of regenerated tissues was effectively improved as well. Taken together, PCL/CS-NO dressing may be a promising candidate for wound treatment, especially for the chronic wound caused by the ischemia. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  5. Biophysical effects of repetitive removal of adhesive dressings on peri-ulcer skin.

    PubMed

    Zillmer, R; Agren, M S; Gottrup, F; Karlsmark, T

    2006-05-01

    To study the effect of repeated removal of four different adhesive dressings on peri-ulcer skin using quantitative non-invasive techniques. Forty-five patients with open (n = 29) or healed (n = 16) venous leg ulcers were included. Peri-ulcer skin was treated for 14 days with patches of two different hydrocolloid-based adhesive dressings, one polyurethane adhesive and one soft silicone adhesive dressing. Normal skin of the patients' ventral forearm was also treated identically. Adhesive patches of the dressings were replaced every second day. The skin barrier function was assessed by measuring transepidermal water loss and stratum corneum hydration by measuring electrical conductance. Thirty-nine patients completed the study. The hydrocolloid adhesives increased transepidermal water loss and conductance while the polyurethane and soft silicone adhesives did not influence these parameters significantly compared with adjacent non-treated peri-ulcer skin. For normal forearm skin, similar relative effects among the four adhesives were found. Repetitive treatment with hydrocolloid-based adhesive dressings induced major functional alterations of the stratum corneum. In contrast, a polyurethane adhesive and a soft silicone adhesive dressing did not alter transepidermal water loss or conductance of peri-ulcer skin.

  6. Peroxide-based oxygen generating topical wound dressing for enhancing healing of dermal wounds.

    PubMed

    Chandra, Prafulla K; Ross, Christina L; Smith, Leona C; Jeong, Seon S; Kim, Jaehyun; Yoo, James J; Harrison, Benjamin S

    2015-01-01

    Oxygen generating biomaterials represent a new trend in regenerative medicine that aims to generate and supply oxygen at the site of requirement, to support tissue healing and regeneration. To enhance the healing of dermal wounds, we have developed a highly portable, in situ oxygen generating wound dressings that uses sodium percarbonate (SPO) and calcium peroxide (CPO) as chemical oxygen sources. The dressing continuously generated oxygen for more than 3 days, after which it was replaced. In the in vivo testing on porcine full-thickness porcine wound model, the SPO/CPO dressing showed enhanced wound healing during the 8 week study period. Quantitative measurements of wound healing related parameters, such as wound closure, reepithelialization, epidermal thickness and collagen content of dermis showed that supplying oxygen topically using the SPO/CPO dressing significantly accelerated the wound healing. An increase in neovascularization, as determined using Von Willebrand factor (vWF) and CD31 staining, was also observed in the presence of SPO/CPO dressing. This novel design for a wound dressing that contains oxygen generating biomaterials (SPO/CPO) for supplying topical oxygen, may find utility in treating various types of acute to chronic wounds. © 2015 by the Wound Healing Society.

  7. Chitosan-based dressing for the treatment of external/accessible bleedings in children with bleeding tendency.

    PubMed

    Misgav, Mudi; Kenet, Gili; Martinowitz, Uriel

    2014-03-01

    Bleeding episodes in patients with congenital or acquired bleeding disorders are usually managed with factor concentrates or blood products. However, external and accessible bleeds may effectively be managed with topical hemostasis. After the application of the Hemcon, a Food and Drug Administration-approved chitosan-based hemostatic dressing was used as the "last resort" to successfully control external bleeds in 2 patients with severe bleeding disorders. We describe a single-center experience with this dressing, including its use in pediatric patients as the first mode of therapy. A total of 5 patients (median age 2 y) with severe bleeding disorders were treated with topical chitosan-based dressing for a total of 6 bleeding episodes. The dressing was used either after the failure of extensive systemic therapy or as the first choice of treatment. In 4 of the 6 episodes, bleeding ceased immediately alleviating the need for systemic therapy. There was no rebleeding after the removal of the dressing and no adverse events or local skin reactions were recorded. Hemostatic dressings, such as the chitosan, should be encouraged for the treatment of external/accessible bleeds, especially among the pediatric patients with bleeding tendency.

  8. Plasma treatments of dressings for wound healing: a review.

    PubMed

    Eswaramoorthy, Nithya; McKenzie, David R

    2017-12-01

    This review covers the use of plasma technology relevant to the preparation of dressings for wound healing. The current state of knowledge of plasma treatments that have potential to provide enhanced functional surfaces for rapid and effective healing is summarized. Dressings that are specialized to the needs of individual cases of chronic wounds such as diabetic ulcers are a special focus. A summary of the biology of wound healing and a discussion of the various types of plasmas that are suitable for the customizing of wound dressings are given. Plasma treatment allows the surface energy and air permeability of the dressing to be controlled, to ensure optimum interaction with the wound. Plasmas also provide control over the surface chemistry and in cases where the plasma creates energetic ion bombardment, activation with long-lived radicals that can bind therapeutic molecules covalently to the surface of the dressing. Therapeutic innovations enabled by plasma treatment include the attachment of microRNA or antimicrobial peptides. Bioactive molecules that promote subsequent cell adhesion and proliferation can also be bound, leading to the recruitment of cells to the dressing that may be stem cells or patient-derived cells. The presence of a communicating cell population expressing factors promotes healing.

  9. Topical Application of Honey on Surgical Wounds: A Randomized Clinical Trial.

    PubMed

    Goharshenasan, Peiman; Amini, Shahideh; Atria, Ali; Abtahi, Hamidreza; Khorasani, Ghasemali

    2016-01-01

    The antimicrobial and anti-inflammatory activity of honey and its ability to accelerate wound healing make it an attractive option in surgical wound care. We performed a randomized clinical trial to compare the efficacy of honey dressing with conventional dressing regarding the aesthetic outcome. Bilateral symmetric incisions in randomly selected plastic surgical patients were randomly covered postoperatively with conventional dressing and honey dressing for five days. The aesthetic outcome of the two sides was rated on a Visual Analog Scale by the surgeon and the patient and compared at month three and six after surgery. Seventy two symmetrical incisions in 52 patients were evaluated during the study. The mean width of the scar after the third and the sixth month was 3.64 +/- 0.83 mm and 3.49 +/- 0.87 mm on the side that received honey dressing and 5.43 +/- 0.05 mm and 5.30+/- 1.35 mm in the control group. Wilcoxon signed-rank test showed significant difference between honey and conventional dressing outcomes at third and sixth month (p < 0.001). The healing process of the surgical wound and its final aesthetic result could be improved by using honey dressing. © 2016 S. Karger GmbH, Freiburg.

  10. Polysaccharide Fabrication Platforms and Biocompatibility Assessment as Candidate Wound Dressing Materials

    PubMed Central

    Aduba, Donald C.; Yang, Hu

    2017-01-01

    Wound dressings are critical for wound care because they provide a physical barrier between the injury site and outside environment, preventing further damage or infection. Wound dressings also manage and even encourage the wound healing process for proper recovery. Polysaccharide biopolymers are slowly becoming popular as modern wound dressings materials because they are naturally derived, highly abundant, inexpensive, absorbent, non-toxic and non-immunogenic. Polysaccharide biopolymers have also been processed into biomimetic platforms that offer a bioactive component in wound dressings that aid the healing process. This review primarily focuses on the fabrication and biocompatibility assessment of polysaccharide materials. Specifically, fabrication platforms such as electrospun fibers and hydrogels, their fabrication considerations and popular polysaccharides such as chitosan, alginate, and hyaluronic acid among emerging options such as arabinoxylan are discussed. A survey of biocompatibility and bioactive molecule release studies, leveraging polysaccharide’s naturally derived properties, is highlighted in the text, while challenges and future directions for wound dressing development using emerging fabrication techniques such as 3D bioprinting are outlined in the conclusion. This paper aims to encourage further investigation and open up new, disruptive avenues for polysaccharides in wound dressing material development. PMID:28952482

  11. A review of aqueous foam in microscale.

    PubMed

    Anazadehsayed, Abdolhamid; Rezaee, Nastaran; Naser, Jamal; Nguyen, Anh V

    2018-06-01

    In recent years, significant progress has been achieved in the study of aqueous foams. Having said this, a better understanding of foam physics requires a deeper and profound study of foam elements. This paper reviews the studies in the microscale of aqueous foams. The elements of aqueous foams are interior Plateau borders, exterior Plateau borders, nodes, and films. Furthermore, these elements' contribution to the drainage of foam and hydraulic resistance are studied. The Marangoni phenomena that can happen in aqueous foams are listed as Marangoni recirculation in the transition region, Marangoni-driven flow from Plateau border towards the film in the foam fractionation process, and Marangoni flow caused by exposure of foam containing photosurfactants under UV. Then, the flow analysis of combined elements of foam such as PB-film along with Marangoni flow and PB-node are studied. Next, we contrast the behavior of foams in different conditions. These various conditions can be perturbation in the foam structure caused by injected water droplets or waves or using a non-Newtonian fluid to make the foam. Further review is about the effect of oil droplets and particles on the characteristics of foam such as drainage, stability and interfacial mobility. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Innovative test method for the estimation of the foaming tendency of substrates for biogas plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moeller, Lucie, E-mail: lucie.moeller@ufz.de; Eismann, Frank, E-mail: info@antoc.de; Wißmann, Daniel, E-mail: d.s.wissmann@gmx.de

    2015-07-15

    Graphical abstract: Display Omitted - Highlights: • Foaming in biogas plants depends on the interactions between substrate and digestate. • Foaming tests enable the evaluation of substrate foaming tendency in biogas plants. • Leipzig foam tester enables foaming tests of substrates prior to use. - Abstract: Excessive foaming in anaerobic digestion occurs at many biogas plants and can cause problems including plugged gas pipes. Unfortunately, the majority of biogas plant operators are unable to identify the causes of foaming in their biogas reactor. The occurrence of foaming is often related to the chemical composition of substrates fed to the reactor.more » The consistency of the digestate itself is also a crucial part of the foam formation process. Thus, no specific recommendations concerning substrates can be given in order to prevent foam formation in biogas plants. The safest way to avoid foaming is to test the foaming tendency of substrates on-site. A possible solution is offered by an innovative foaming test. With the help of this tool, biogas plant operators can evaluate the foaming disposition of new substrates prior to use in order to adjust the composition of substrate mixes.« less

  13. Development of Defoamers for Confinenment Foam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoffman, D M; Mitchell, A R

    Aqueous foam concentrate (AFC) 380 foam was developed by Sandia National Laboratory as a blast mitigation foam for unexploded ordnance (UXO) and its ''engineered foam structure'' is reported to be able to ''envelop chemical or biological aerosols'' [1]. It is similar to commercial fire-fighting foams, consisting mostly of water with small amounts of two alcohols, an ether and surfactant. It also contains xanthan gum, probably, to strengthen the foam film and delay drainage. The concentrate is normally diluted in a 6:94 ratio with water for foaming applications. The diluted solution is normally foamed with air to an expansion factor ofmore » about 100 (density 0.01 g/cc), which is called ''dry'' foam. Higher density foam (0.18 > {rho} > 0.03 g/cc) was discovered which had quite different characteristics from ''dry'' foam and was called ''wet'' foam. Some characterization of these foams has also been carried out, but the major effort described in this document is the evaluation, at the small and medium scale, of chemical, mechanical and thermal approaches to defoaming AFC 380 foam. Several chemical approaches to defoaming were evaluated including oxidation and precipitation of the xanthan, use of commercial oil-emulsion or suspension defoamers, pH modification, and cation exchange with the surfactant. Of these the commercial defoamers were most effective. Two mechanical approaches to defoaming were evaluated: pressure and foam rupture with very fine particles. Pressure and vacuum techniques were considered too difficult for field applications but high surface area silica particles worked very well on dry foam. Finally simple thermal techniques were evaluated. An order-disorder transition occurs in xanthan solutions at about 60 C, which may be responsible for the effectiveness of hot air as a defoamer. During defoaming of 55 gallons of foam with hot air, after about 70% of the AFC 380 foam had been defoamed, the effectiveness of hot air was dramatically reduced. Approximately 15 gal of residual foam containing mostly small bubbles was resistant to further defoaming by methods that had been effective on the original, dry foam. In this paper the residual foam is referred to as ''wet'' and the original foam is referred to as ''dry''. Methods for generating ''wet'' foam in small to moderate quantities for defoaming experiments have been developed. Methods for defoaming wet foam are currently under study.« less

  14. 40 CFR 63.8830 - What definitions apply to this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication... chemical substance that is applied for the purpose of bonding foam to foam, foam to fabric, or foam to any... means the process of bonding flexible foam to one or more layers of material by heating the foam surface...

  15. 40 CFR 63.8830 - What definitions apply to this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication... chemical substance that is applied for the purpose of bonding foam to foam, foam to fabric, or foam to any... means the process of bonding flexible foam to one or more layers of material by heating the foam surface...

  16. 40 CFR 63.8830 - What definitions apply to this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication... chemical substance that is applied for the purpose of bonding foam to foam, foam to fabric, or foam to any... means the process of bonding flexible foam to one or more layers of material by heating the foam surface...

  17. 40 CFR 63.8830 - What definitions apply to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication... chemical substance that is applied for the purpose of bonding foam to foam, foam to fabric, or foam to any... means the process of bonding flexible foam to one or more layers of material by heating the foam surface...

  18. 40 CFR 63.8830 - What definitions apply to this subpart?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication... chemical substance that is applied for the purpose of bonding foam to foam, foam to fabric, or foam to any... means the process of bonding flexible foam to one or more layers of material by heating the foam surface...

  19. Fabrication of low-crystalline carbonate apatite foam bone replacement based on phase transformation of calcite foam.

    PubMed

    Maruta, Michito; Matsuya, Shigeki; Nakamura, Seiji; Ishikawa, Kunio

    2011-01-01

    Carbonate apatite (CO(3)Ap) foam may be an ideal bone substitute as it is sidelined to cancellous bone with respect to its chemical composition and structure. However, CO(3)Ap foam fabricated using α-tricalcium phosphate foam showed limited mechanical strength. In the present study, feasibility of the fabrication of calcite which could be a precursor of CO(3)Ap was studied. Calcite foam was successfully fabricated by the so-called "ceramic foam" method using calcium hydroxide coated polyurethane foam under CO(2)+O(2) atmosphere. Then the calcite foam was immersed in Na(2)HPO(4) aqueous solution for phase transformation based on dissolution-precipitation reaction. When CaO-free calcite foam was immersed in Na(2)HPO(4) solution, low-crystalline CO(3)Ap foam with 93-96% porosity and fully interconnected porous structure was fabricated. The compressive strength of the foam was 25.6 ± 6 kPa. In light of these results, we concluded that the properties of the precursor foam were key factors for the fabrication of CO(3)Ap foams.

  20. Efficient continuous dryer for flexible polyurethane foam and cleaning apparatus

    DOEpatents

    Jody, Bassam; Daniels, Edward; Libera, Joseph A.

    1999-01-01

    A method of cleaning polyurethane foams where the material is transported through a wash station while alternately soaking the polyurethane foam in an organic solvent and squeezing solvent from the polyurethane foam a number of times. Then the polyurethane foam is sent through a rinse or solvent transfer station for reducing the concentration of solvent in the foam. The rinsed polyurethane foam is sent to a drying station wherein the foam is repeatedly squeezed while being exposed to hot air to remove wet air from the foam.

  1. Efficient continuous dryer for flexible polyurethane foam and cleaning apparatus

    DOEpatents

    Jody, B.; Daniels, E.; Libera, J.A.

    1999-03-16

    A method of cleaning polyurethane foams where the material is transported through a wash station while alternately soaking the polyurethane foam in an organic solvent and squeezing solvent from the polyurethane foam a number of times. Then the polyurethane foam is sent through a rinse or solvent transfer station for reducing the concentration of solvent in the foam. The rinsed polyurethane foam is sent to a drying station wherein the foam is repeatedly squeezed while being exposed to hot air to remove wet air from the foam. 4 figs.

  2. Fatty acid sulphoalkyl amides and esters as cosmetic surfactants.

    PubMed

    Petter, P J

    1984-10-01

    Synopsis A review is given of the manufacture, properties and applications of the anionic surfactants commonly known as taurates and isethionates (fatty acid sulphoalkyl amides and esters, respectively). Originally developed in the 1930s for textile processing, these surfactants are used increasingly in the cosmetic field, particularly those derived from coconut fatty acid. Both types are produced from sodium isethionate, HO degrees C(2)H(4)SO(3)Na. The acyl isethionate, R degrees COO degrees C(2)H(4)SO(3)Na, is obtained by reaction with a fatty acid ('direct process'). or fatty acid chloride ('indirect process'). The direct process is cheaper but requires extreme conditions which can lead to discoloration of the product and a loss of shorter chain fatty acid components. The N-methyl-N-acyltaurate, R degrees CON(R(1))C(2)H(4)SO(3)Na, is obtained by Schotten-Baumann reaction of a fatty acid chloride with N-methyltaurine, which is derived from sodium isethionate via methylamine. Taurates and isethionates retain the benefits of the soaps to which they are structurally similar, but chemical modifications have eliminated many undesirable features. Thus they combine good detergency and wetting with high foaming, and maintain their performance in hard or salt water. Taurates are stable to hydrolysis over the whole pH range. Isethionates are prone to hydrolysis at high (>8) or low (<5) pH, but this does not normally present a problem in cosmetic formulations. Above all, these surfactants are characterized by their extreme mildness to skin. Syndet and syndet/soap bars based on isethionate can be formulated at neutral pH ('Dove type'bars) instead of the alkaline pH of soap, and have been shown in various studies to be milder than soap and better tolerated by the young, the old and those with sensitive skins. Similarly, isethionates have been shown to be less irritating than other anionic or amphoteric surfactants used in cosmetics. The difference has been related to the negligible effect of isethionate on the water-binding capacity of stratum corneum. Other cosmetic applications besides toilet bars include shampoos (excellent cleaning, mild to scalp, some hair conditioning effects), liquid soaps (mild for all-over body use), bubble baths (copious stable foam, efficient lime soap dispersal, low irritancy), skin creams and lotions (emulsification, alleviation of 'dry skin'), baby care products (ultra-mild cleansing bars and milks, impregnated baby wipes) and oral products (foaming agents with low toxicity for toothpastes and mouthwashes).

  3. Handbook for using foams to control vapors from hazardous spills. Report for April 1984-September 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, M.L.; Carroll, H.A.

    1986-07-01

    The handbook describes basic types of foams that may be used to control vapor hazards from spilled volatile chemicals. It provides a table to be used by spill-response personnel to choose an appropriate foam based on the type of chemical spill. Six general types of foams, surfactant (syndet) foams, aqueous film forming foams (AFFF), alcohol type or polar solvent type foams (ATF), and special foams such as Hazmat NF no. 1 which was developed especially for alkaline spills. The handbook provides the basis for spill responders to evaluate and select a foam for vapor control by using the test methodsmore » presented or by considering manufacturers specifications for foam-expansion ratios and quarter drainage times. The responder is encouraged to maximize the effectiveness of a foam by trying different nozzles, distances of applications, and thicknesses of the foam layers.« less

  4. Controlled Release of Chitosan and Sericin from the Microspheres-Embedded Wound Dressing for the Prolonged Anti-microbial and Wound Healing Efficacy.

    PubMed

    Aramwit, Pornanong; Yamdech, Rungnapha; Ampawong, Sumate

    2016-05-01

    One approach in wound dressing development is to incorporate active molecules or drugs in the dressing. In order to reduce the frequency of dressing changes as well as to prolong wound healing efficacy, wound dressings that can sustain the release of the active molecules should be developed. In our previous work, we developed chitosan/sericin (CH/SS) microspheres that released sericin in a controlled rate. However, the difficulty of applying the microspheres that easily diffuse and quickly degrade onto the wound was its limitations. In this study, we aimed to develop wound dressing materials which are easier to apply and to provide extended release of sericin. Different amounts of CH/SS microspheres were embedded into various compositions of polyvinyl alcohol/gelatin (PVA/G) scaffolds and fabricated using freeze-drying and glutaraldehyde crosslinking techniques. The obtained CH/SS microspheres-embedded scaffolds with appropriate design and formulation were introduced as a wound dressing material. Sericin was released from the microspheres and the scaffolds in a sustained manner. Furthermore, an optimized formation of the microspheres-embedded scaffolds (2PVA2G+2CHSS) was shown to possess an effective antimicrobial activity against both gram-positive and gram-negative bacteria. These microspheres-embedded scaffolds were not toxic to L929 mouse fibroblast cells, and they did not irritate the tissue when applied to the wound. Finally, probably by the sustained release of sericin, these microspheres-embedded scaffolds could promote wound healing as well as or slightly better than a clinically used wound dressing (Allevyn®) in a mouse model. The antimicrobial CH/SS microspheres-embedded PVA/G scaffolds with sustained release of sericin would appear to be a promising candidate for wound dressing application.

  5. A prospective, randomised study of a novel transforming methacrylate dressing compared with a silver-containing sodium carboxymethylcellulose dressing on partial-thickness skin graft donor sites in burn patients.

    PubMed

    Assadian, Ojan; Arnoldo, Brett; Purdue, Gary; Burris, Agnes; Skrinjar, Edda; Duschek, Nikolaus; Leaper, David J

    2015-06-01

    This prospective, randomised study compares a new transforming methacrylate dressing (TMD) with a silver-containing carboxymethylcellulose dressing (CMC-Ag) after application to split-thickness skin graft (STSG) donor sites. This was an unblinded, non-inferiority, between-patient, comparison study that involved patients admitted to a single-centre burn unit who required two skin graft donor sites. Each patient's donor sites were covered immediately after surgery: one donor site with TMD and the other with CMC-Ag. The donor sites were evaluated until healing or until 24 days post-application, whichever came first. Study endpoints were time to healing, daily pain scores, number of dressing changes, patient comfort and physicians' and patients' willingness to use the dressings in the future. Nineteen patients had both the dressings applied. No statistically significant difference was noted in time to healing between the two dressings (14·2 days using TMD compared with 13·2 days using CMC-Ag). When pain scores were compared, TMD resulted in statistically significantly less pain at three different time periods (2-5 days, 6-10 days and 11-15 days; P < 0·001 at all time periods). Patients also reported greater comfort with TMD (P < 0·001). Users rated TMD as being less easy to use because of the time and technique required for application. Reductions in pain and increased patient comfort with the use of the TMD dressing, compared with CMC-Ag, were seen as clinical benefits as these are the major issues in donor site management. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  6. Difficult clinical management of antituberculosis DRESS syndrome complicated by MRSA infection: A case report.

    PubMed

    Wang, Li; Li, Lin-Feng

    2017-03-01

    Drug reaction with eosinophilia and systemic symptoms (DRESS) syndrome is a severe drug-induced hypersensitivity reaction characterized by skin rash, fever, blood abnormalities, and multiple organ involvement. The diagnosis of DRESS syndrome is often delayed because of its variable presentation. Prompt withdrawal of the culprit drug is the definitive treatment. DRESS syndrome induced by antituberculosis drugs has rarely been reported. A 50-year-old man admitted to our hospital with recurrent episodes of progressive rash, fever, eosinophilia, lymphadenopathy, hepatic, and pulmonary involvement were experienced after repeat trials of the same antituberculosis drugs. We diagnosed it as DRESS caused by antituberculosis drugs. The case responded well to treatment with systemic corticosteroids and intravenous immunoglobulins. However, repeated bouts of infection with methicillin-resistant Staphylococcus aureus occurred during treatment (clavicular osteomyelitis and knee septic arthritis). He was cured after treatment with linezolid. The patient was discharged on day 112. At 8-month follow-up, there was no relapse of drug eruption and joint swelling. Early diagnosis and prompt withdrawal of all suspected drugs is a key tenet of the treatment of DRESS. Our case report highlights the risks inherent in delayed diagnosis of DRESS and the challenges in the clinical management of this condition. Pulmonary manifestations with radiological changes on chest X-ray and CT can be seen in DRESS. These changes need to be differentiated from those caused by pulmonary infections. Clavicular osteomyelitis infected with MRSA may be caused by iatrogenic injury during subclavian vein catheterization. This type of MRSA infections should be treated for 4 to 6 weeks. Blood eosinophilia could be a useful marker of disease progression and treatment response in patients with DRESS. However, more experience and clinical evidence is needed to confirm this.

  7. Evaluation of a new pressure ulcer preventive dressing containing ceramide 2 with low frictional outer layer.

    PubMed

    Nakagami, Gojiro; Sanada, Hiromi; Konya, Chizuko; Kitagawa, Atsuko; Tadaka, Etsuko; Matsuyama, Yutaka

    2007-09-01

    This paper is a report of an evaluation of the effectiveness of a newly developed dressing for preventing persistent erythema and pressure ulcer development and improving the water-holding capacity without increasing the skin pH in bedridden older patients. Shear forces and skin dryness play important roles in persistent erythema and pressure ulcer development. To eliminate these risks, we developed a dressing to reduce shear forces and improve the water-holding capacity. However, the effects of this dressing in clinical settings remain unknown. An experimental bilateral comparison study was conducted at a hospital in Japan in 2004 with 37 bedridden older patients at risk of pressure ulcer development. The dressing was randomly applied to the right or left greater trochanter for 3 weeks. No dressing was applied to the opposite side as a control. The skin was monitored weekly during the 3-week application for persistent erythema and pressure ulcer development. Skin hydration and pH were also assessed during the intervention and for 1 week after dressing removal. The incidence of persistent erythema was significantly lower in the intervention area than the control area [P = 0.007, RR 0.18 (95% CI: 0.05-0.73) and NNT 4.11 (2.50-11.63) ]. No pressure ulcers occurred in either the intervention or control area. Skin hydration increased significantly during dressing application and remained high after removal (P < 0.001) relative to the control area. Skin pH decreased significantly during the application (P < 0.001) but returned to control levels after removal (P = 0.38). This safe and effective dressing can be used for patients with highly prominent bones and dry skin to prevent pressure ulcers.

  8. Patients' attitudes toward the attire of male physicians: a single-center study in Saudi Arabia.

    PubMed

    Batais, Mohammad Ali

    2014-01-01

    The doctor-patient relationship has been influenced by the appearance of physicians, and there is an association between a physician's physical appearance and the patients' initial perceptions of physician competence. This study aims to explore patients' preferences toward the attire of a male physician, and to examine if a physician's choice of uniform influences the degree of trust, confidence, and follow-up care among respondents. A cross-sectional survey conducted among patients of the Alwazarat family medicine center in Riyadh, Saudi Arabia. A self-administered questionnaire was completed by 300 patients (50% were male and 83.6% had received a secondary education; the mean age was 33.4 [10.1] years) in the Alwazarat family medicine center in Riyadh. The questionnaire was also customized for the local setting with the inclusion of photos of a male doctor in Saudi Arabian national costume, and 3 other dress styles (Western dress with white coat, scrubs with white coat, and scrubs only). Overall, across all questions regarding physician dress style preferences, participants significantly preferred Western dress (39.9%, P < .001), followed by Saudi national dress (26.3%), a scrub suit with a white coat (22.3%), and scrubs only (11.5%). Respondents reported that they were more likely to follow medical advice and would return for follow-up care if a physician wore Western dress. They were significantly more willing to share their social, sexual, and psychological problems with a physician wearing Saudi national dress (P < .001). The importance of a physician's appearance was ranked significantly higher by older patients (P=.002). Respondents were more likely to favor a physician wearing Western attire with a white coat. However, Saudi national dress, followed by Western dress, is the preferred attire when physicians are dealing with social, sexual, and psychological problems.

  9. Development and formulation of Moringa oleifera standardised leaf extract film dressing for wound healing application.

    PubMed

    Chin, Chai-Yee; Jalil, Juriyati; Ng, Pei Yuen; Ng, Shiow-Fern

    2018-02-15

    M.oleifera is a medicinal plant traditionally used for skin sores, sore throat and eye infections. Recently, the wound healing property of the leaves of M. oleifera was has been well demonstrated experimentally in both in vivo and in vitro models. However, there is a lack of research which focuses on formulating M.oleifera into a functional wound dressing. In this study, the M.oleifera leaf standardized aqueous extract with highest potency in vitro migration was formulated into a film for wound healing application. Firstly, M. oleifera leaf were extracted in various solvents (aqueous, 50%, 70% and 100% ethanolic extracts) and standardized by reference standards using UHPLC technique. The extracts were then tested for cell migration and proliferation using HDF and HEK cell lines. M. oleifera leaf aqueous extract was then incorporated into alginate-pectin (SA-PC) based film dressing. The film dressings were characterized for the physicochemical properties and the bioactives release from the M. oleifera leaf extract loaded film dressing was also investigated using Franz diffusion cells. All extracts were found to contain vicenin-2, chlorogenic acid, gallic acid, quercetin, kaempferol, rosmarinic acid and rutin. Among all M. oleifera extracts, aqueous standardized leaf extracts showed the highest human dermal fibroblast and human keratinocytes cells proliferation and migration properties. Among the film formulations, SA-PC (3% w/v) composite film dressing containing M. oleifera aqueous leaf extract was found to possess optimal physicochemical properties as wound dressing. A potentially applicable wound dressing formulated as an alginate-pectin film containing aqueous extracts of M. oleifera has been developed. The dressing would be suitable for wounds with moderate exudates. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Surgical site infections following colorectal cancer surgery: a randomized prospective trial comparing common and advanced antimicrobial dressing containing ionic silver.

    PubMed

    Biffi, Roberto; Fattori, Luca; Bertani, Emilio; Radice, Davide; Rotmensz, Nicole; Misitano, Pasquale; Cenciarelli, Sabine; Chiappa, Antonio; Tadini, Liliana; Mancini, Marina; Pesenti, Giovanni; Andreoni, Bruno; Nespoli, Angelo

    2012-05-23

    An antimicrobial dressing containing ionic silver was found effective in reducing surgical-site infection in a preliminary study of colorectal cancer elective surgery. We decided to test this finding in a randomized, double-blind trial. Adults undergoing elective colorectal cancer surgery at two university-affiliated hospitals were randomly assigned to have the surgical incision dressed with Aquacel Ag Hydrofiber dressing or a common dressing. To blind the patient and the nursing and medical staff to the nature of the dressing used, scrub nurses covered Aquacel Ag Hydrofiber with a common wound dressing in the experimental arm, whereas a double common dressing was applied to patients of control group. The primary end-point of the study was the occurrence of any surgical-site infection within 30 days of surgery. A total of 112 patients (58 in the experimental arm and 54 in the control group) qualified for primary end-point analysis. The characteristics of the patient population and their surgical procedures were similar. The overall rate of surgical-site infection was lower in the experimental group (11.1% center 1, 17.5% center 2; overall 15.5%) than in controls (14.3% center 1, 24.2% center 2, overall 20.4%), but the observed difference was not statistically significant (P = 0.451), even with respect to surgical-site infection grade 1 (superficial) versus grades 2 and 3, or grade 1 and 2 versus grade 3. This randomized trial did not confirm a statistically significant superiority of Aquacel Ag Hydrofiber dressing in reducing surgical-site infection after elective colorectal cancer surgery. Clinicaltrials.gov: NCT00981110.

  11. Application of the Single Use Negative Pressure Wound Therapy Device (PICO) on a Heterogeneous Group of Surgical and Traumatic Wounds

    PubMed Central

    Payne, Caroline; Edwards, Daren

    2014-01-01

    Objectives: Traumatic wounds and surgery inherently have their complications. Localized infections, wound dehiscence, and excessive wound leakage can be devastating to the patient with a prolonged recovery, but it is also costly to the hospital with an increased length of stay, extra workload, and dressing changes. The single use PICO (Smith and Nephew Healthcare, Hull, United Kingdom) negative pressure wound therapy (NPWT) dressing has revolutionized our management of various acute, chronic, and high output wounds. It requires fewer dressing changes than conventional practice, is used in the outpatient setting, and is a necessary adjuvant therapy to hasten wound healing. Aims: To observe the efficacy of the PICO vacuum-assisted healing within a cost improvement programme. Settings: Plastic surgery department, Royal London Hospital. Materials and Methods: Twenty-one patients with a diversity of postoperative or posttraumatic wounds were considered suitable for PICO application and treated totally on an outpatient basis once the PICO dressing was applied. All wounds were then subjected to continued PICO dressings until healed. Results: All patients tolerated the PICO well with no dressing failure or failure to comply. The number of dressings per patient ranged from 1 to 7. The cost per patient of treatment ranged from £120 to £1578. Estimated cost of all PICO dressing for 21 patients including plastic surgery dressing clinic appointments = £13,345. Median length of treatment to healing (days) = 16; standard deviation = 9.5. Eight patients would have had an inpatient bed stay with conventional therapy, total 24 bed days saved at Bartshealth @£325 per day. Conclusions: The outpatient application of a disposable NPWT can benefit a wide range of clinical wounds that optimizes patient care, promotes rapid wound healing, and importantly helps manage costs. PMID:24917894

  12. Unit costs for house spraying and bednet impregnation with residual insecticides in Colombia: a management tool for the control of vector-borne disease.

    PubMed

    Kroeger, A; Ayala, C; Medina Lara, A

    2002-06-01

    A study of unit costs and cost components of two malaria-control strategies (house spraying and bednet impregnation with residual insecticides) was undertaken in 11 malaria-endemic states (departamentos) of Colombia, using data provided by control staff on self-administered questionnaires. The accuracy of the data was verified by personal visits, telephone conversations and complementary information from 10 other states. Allthe financial-cost components of the malaria-control operations carried out in the previous 6 months and the results of the control operations themselves (including the numbers of houses sprayed and numbers of bednets impregnated/day) were recorded. The information was stratified according to whether the target communities were 'near' or 'far away' from an operational base, the far-away communities being those that needed overnight stays by the control staff. The main variables analysed were unit costs/house treated, and annual cost/person protected. The results show that house spraying was generally more expensive for the health services than bednet impregnation. This is particularly the case in 'nearby' communities, where most of those at-risk live. In such communities, spraying one house was 7.2 times more expensive than impregnating one bednet. Even if only those sleeping under an impregnated net were assumed to be protected, the unit costs/person protected in a 'nearby' community were twice as high for house spraying than for bednet impregnation. In 'nearby' communities, where technicians could return to the operational base each evening, insecticides made up 80% of the total spraying costs and 42% of the costs of bednet impregnation. In 'far-away' communities, however, salaries and 'per diems' were the most important cost components, representing, respectively, 23% and 22% of the costs of spraying, and 34% plus 27% of the costs of impregnation. Insecticide wastage and non-use of discounts on insecticide prices (available through the national Ministry of Health) increased the overall costs considerably. The multiple uses of these cost calculations for district health managers are presented.

  13. Devices and dressings to secure peripheral venous catheters to prevent complications.

    PubMed

    Marsh, Nicole; Webster, Joan; Mihala, Gabor; Rickard, Claire M

    2015-06-12

    A peripheral venous catheter (PVC) is typically used for short-term delivery of intravascular fluids and medications. It is an essential element of modern medicine and the most frequent invasive procedure performed in hospitals. However, PVCs often fail before intravenous treatment is completed: this can occur because the device is not adequately attached to the skin, allowing the PVC to fall out, leading to complications such as phlebitis (irritation or inflammation to the vein wall), infiltration (fluid leaking into surrounding tissues) or occlusion (blockage). An inadequately secured PVC also increases the risk of catheter-related bloodstream infection (CRBSI), as the pistoning action (moving back and forth in the vein) of the catheter can allow migration of organisms along the catheter and into the bloodstream. Despite the many dressings and securement devices available, the impact of different securement techniques for increasing PVC dwell time is still unclear; there is a need to provide guidance for clinicians by reviewing current studies systematically. To assess the effects of PVC dressings and securement devices on the incidence of PVC failure. We searched the following electronic databases to identify reports of relevant randomised controlled trials (RCTs): the Cochrane Wounds Group Register (searched 08 April 2015): The Cochrane Central Register of Controlled Trials (CENTRAL; 2015, Issue 3), Ovid MEDLINE (1946 to March 7 2015); Ovid MEDLINE (In-Process & Other Non-Indexed Citations, March 7 2015); Ovid EMBASE (1974 to March 7 2015); and EBSCO CINAHL (1982 to March 8 2015). RCTs or cluster RCTs comparing different dressings or securement devices for the stabilisation of PVCs. Cross-over trials were ineligible for inclusion, unless data for the first treatment period could be obtained. Two review authors independently selected studies, assessed trial quality and extracted data. We contacted study authors for missing information. We used standard methodological procedures expected by Cochrane. We included six RCTs (1539 participants) in this review. Trial sizes ranged from 50 to 703 participants. These six trials made four comparisons, namely: transparent dressings versus gauze; bordered transparent dressings versus a securement device; bordered transparent dressings versus tape; and transparent dressing versus sticking plaster. There is very low quality evidence of fewer catheter dislodgements or accidental removals with transparent dressings compared with gauze (two studies, 278 participants, RR 0.40; 95% CI 0.17 to 0.92, P = 0.03%). The relative effects of transparent dressings and gauze on phlebitis (RR 0.89; 95% CI 0.47 to 1.68) and infiltration (RR 0.80; 95% CI 0.48 to 1.33) are unclear. The relative effects on PVC failure of a bordered transparent dressing and a securement device have been assessed in only one small study and these were unclear. There was very low quality evidence from the same single study of less frequent dislodgement or accidental catheter removal with bordered transparent dressings than securement devices (RR 0.14, 95% CI 0.03 to 0.63) but more phlebitis with bordered dressings (RR 8.11, 95% CI 1.03 to 64.02) (very low quality evidence). A small single study compared bordered transparent dressings with tape and found very low quality evidence of more PVC failure with the bordered dressing (RR 1.84, 95% CI 1.08 to 3.11) but the relative effects on dislodgement were not clear (very low quality evidence). The relative effects of transparent dressings and a sticking plaster have only been compared in one small study and are unclear. More high quality RCTs are required to determine the relative effects of alternative PVC dressings and securement devices. It is not clear if any one dressing or securement device is better than any other in securing peripheral venous catheters. There is a need for further, independent high quality trials to evaluate the many traditional as well as the newer, high use products. Given the large cost differences between some different dressings and securement devices, future trials should include a robust cost-effectiveness analysis.

  14. Forming foam structures with carbon foam substrates

    DOEpatents

    Landingham, Richard L.; Satcher, Jr., Joe H.; Coronado, Paul R.; Baumann, Theodore F.

    2012-11-06

    The invention provides foams of desired cell sizes formed from metal or ceramic materials that coat the surfaces of carbon foams which are subsequently removed. For example, metal is located over a sol-gel foam monolith. The metal is melted to produce a metal/sol-gel composition. The sol-gel foam monolith is removed, leaving a metal foam.

  15. Use of Collagen Extracellular Matrix Dressing for the Treatment of a Recurrent Venous Ulcer in a 52-Year-Old Patient.

    PubMed

    González, Arturo

    2016-01-01

    This case study describes treatment for a 52-year-old man with a recurrent venous leg ulcer using a collagen dressing with extracellular matrix. The patient was admitted to the wound care service for a 3-week-old recurrent venous ulcer. Treatment included application of a collagen dressing with extracellular matrix twice weekly or as needed by the patient; application of a secondary dressing (4 × 4 gauze); and coverage with an expandable netting or gauze using a conforming stretch gauze bandage and latex-free dressing retention tape. The initial venous leg ulcer in this patient required 10 weeks to achieve closure. Ninety-eight percent resolution of the recurrent ulcer had occurred within 4 weeks of treatment, with complete closure at 7 weeks. The average healing time for recurrent venous ulcers is reported in the literature to be longer than initial venous ulcers. In the case provided, collagen ECM dressings promoted complete wound healing in 49 days.

  16. Application of VitaVallis dressing for infected wounds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirilova, N. V., E-mail: n.kirilova@vitavallis.com; Fomenko, A. N., E-mail: alserova@ispms.tsc.ru; Korovin, M. S., E-mail: msk@ispms.tsc.ru

    Today there is a growing demand for safe and efficient antimicrobial dressings for infected wound treatment. The antimicrobial sorption material for VitaVallis dressings was produced by one-stage oxidation of aluminum nanopowder in water in the presence of fibrous acetylcellulose matrix. Scanning electron microscopy revealed that the material is made up of fibers of diameter 1.5–3.0 µm with adhered agglomerated alumina nanosheets. An antimicrobial study revealed a high inhibitory effect of VitaVallis against the growth of gram-negative (E.coli, P. aeruginosa) and gram-positive (S. aureus) strains. The antimicrobial activity of the dressing against microbial pathogens on the wound surface was demonstrated in inmore » vivo experiments on male rats. The dressing was also tested on volunteer patients. The testing showed reduction of the wound healing period, accelerated cleaning of the infected wound and enhanced tissue regeneration in the wound. The results demonstrate that the VitaVallis dressing can be used for the treatment of deep infected wounds.« less

  17. A new methodology for evaluating the damage to the skin barrier caused by repeated application and removal of adhesive dressings.

    PubMed

    Waring, Mike; Bielfeldt, Stephan; Mätzold, Katja; Wilhelm, Klaus-Peter

    2013-02-01

    Chronic wounds require frequent dressing changes. Adhesive dressings used for this indication can be damaging to the stratum corneum, particularly in the elderly where the skin tends to be thinner. Understanding the level of damage caused by dressing removal can aid dressing selection. This study used a novel methodology that applied a stain to the skin and measured the intensity of that stain after repeated application and removal of a series of different adhesive types. Additionally, a traditional method of measuring skin barrier damage (transepidermal water loss) was also undertaken and compared with the staining methodology. The staining methodology and measurement of transepidermal water loss differentiated the adhesive dressings, showing that silicone adhesives caused least trauma to the skin. The staining methodology was shown to be as effective as transepidermal water loss in detecting damage to the stratum corneum and was shown to detect disruption of the barrier earlier than the traditional technique. © 2012 John Wiley & Sons A/S.

  18. Controlled trial of Iodosorb in chronic venous ulcers.

    PubMed Central

    Ormiston, M C; Seymour, M T; Venn, G E; Cohen, R I; Fox, J A

    1985-01-01

    Cadexomer iodine (Iodosorb) is a hydrophilic starch powder containing iodine, which is a suitable dressing for granulating wounds such as venous ulcers. A total of 61 outpatients with chronic venous ulcers participated in a randomised optional crossover trial using cadexomer iodine or a standard dressing for their ulcers. The trial lasted for 24 weeks or until the ulcer had healed. Two patients withdrew during the course of the trial. Both treatments were highly effective, but the epithelium of ulcers dressed with cadexomer iodine grew again significantly faster (p less than 0.001). At the midpoint of the trial (12th week) 13 of 30 patients receiving standard treatment were changed to cadexomer iodine, while only three of 29 receiving cadexomer iodine changed to the standard dressing (p less than 0.02). In most cases ulcers were dressed and rebandaged daily by the patients themselves after instruction and supervision. This may be better than having dressings and bandages applied by professionals less regularly. PMID:3926169

  19. Gelam (Melaleuca spp.) Honey-Based Hydrogel as Burn Wound Dressing

    PubMed Central

    Mohd Zohdi, Rozaini; Abu Bakar Zakaria, Zuki; Yusof, Norimah; Mohamed Mustapha, Noordin; Abdullah, Muhammad Nazrul Hakim

    2012-01-01

    A novel cross-linked honey hydrogel dressing was developed by incorporating Malaysian honey into hydrogel dressing formulation, cross-linked and sterilized using electron beam irradiation (25 kGy). In this study, the physical properties of the prepared honey hydrogel and its wound healing efficacy on deep partial thickness burn wounds in rats were assessed. Skin samples were taken at 7, 14, 21, and 28 days after burn for histopathological and molecular evaluations. Application of honey hydrogel dressings significantly enhanced (P < 0.05) wound closure and accelerated the rate of re-epithelialization as compared to control hydrogel and OpSite film dressing. A significant decrease in inflammatory response was observed in honey hydrogel treated wounds as early as 7 days after burn (P < 0.05). Semiquantitative analysis using RT-PCR revealed that treatment with honey hydrogel significantly (P < 0.05) suppressed the expression of proinflammatory cytokines (IL-1α, IL-1β, and IL-6). The present study substantiates the potential efficacy of honey hydrogel dressings in accelerating burn wound healing. PMID:21941590

  20. Drug Reaction with Eosinophilia and Systemic Symptom (DRESS) induced by carbamazepine: a case report and literature review

    PubMed Central

    EL Omairi, Nissrine; Abourazzak, Sanae; Chaouki, Sanae; Atmani, Samir; Hida, Moustapha

    2014-01-01

    Drug-induced hypersensitivity or Drug Reaction with Eosinophilia and Systemic Symptom (DRESS) is a severe adverse drug-induced reaction. Diagnosing DRESS is challenging due to the diversity of cutaneous eruption and organs involved. Most of the aromatic anticonvulsants, such as phenytoin, phenobarbital, and carbamazepine, can induce DRESS. Culprit drug withdrawal and corticosteroids constituted the mainstay of DRESS treatment. We describe a 6 year-old boy who presented fever and rash 4 weeks after starting carbamazepine. Investigation revealed leukocytosis, atypical lymphocytosis, and elevated serum transaminases. The diagnosis of DREES syndrome was made, Carbamazepine was stopped and replaced initially by Clobazam and by Valproic acid after discharge, no systemic corticotherapy was prescribed. Symptoms began to resolve within two weeks, and by one month later her laboratory values had returned to normal. The aim of this work is to raise awareness general practitioner and pediatricians to suspect Dress syndrome in patients who present with unusual complaints and skin findings after starting any antiepileptic drug. PMID:25360193

  1. Effects of wound dressings on cultured primary keratinocytes.

    PubMed

    Esteban-Vives, Roger; Young, Matthew T; Ziembicki, Jenny; Corcos, Alain; Gerlach, Jörg C

    2016-02-01

    Autologous cell-spray grafting of non-cultured epidermal cells is an innovative approach for the treatment of severe second-degree burns. After treatment, wounds are covered with dressings that are widely used in wound care management; however, little is known about the effects of wound dressings on individually isolated cells. The sprayed cells have to actively attach, spread, proliferate, and migrate in the wound for successful re-epithelialization, during the healing process. It is expected that exposure to wound dressing material might interfere with cell survival, attachment, and expansion. Two experiments were performed to determine whether some dressing materials have a negative impact during the early phases of wound healing. In one experiment, freshly isolated cells were seeded and cultured for one week in combination with eight different wound dressings used during burn care. Cells, which were seeded and cultured with samples of Adaptic(®), Xeroform(®), EZ Derm(®), and Mepilex(®) did not attach, nor did they survive during the first week. Mepitel(®), N-Terface(®), Polyskin(®), and Biobrane(®) dressing samples had no negative effect on cell attachment and cell growth when compared to the controls. In a second experiment, the same dressings were exposed to pre-cultured cells in order to exclude the effects of attachment and spreading. The results confirm the above findings. This study could be of interest for establishing skin cell grafting therapies in burn medicine and also for wound care in general. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  2. Efficacy of a surfactant-based wound dressing on biofilm control.

    PubMed

    Percival, Steven L; Mayer, Dieter; Salisbury, Anne-Marie

    2017-09-01

    The aim of this study was to evaluate the efficacy of both a nonantimicrobial and antimicrobial (1% silver sulfadiazine-SSD) surfactant-based wound dressing in the control of Pseudomonas aeruginosa, Enterococcus sp, Staphylococcus epidermidis, Staphylococcus aureus, and methicillin-resistant S. aureus (MRSA) biofilms. Anti-biofilm efficacy was evaluated in numerous adapted American Standards for Testing and Materials (ASTM) standard biofilm models and other bespoke biofilm models. The ASTM standard models employed included the Minimum biofilm eradication concentration (MBEC) biofilm model (ASTM E2799) and the Centers for Disease Control (CDC) biofilm reactor model (ASTM 2871). Such bespoke biofilm models included the filter biofilm model and the chamberslide biofilm model. Results showed complete kill of microorganisms within a biofilm using the antimicrobial surfactant-based wound dressing. Interestingly, the nonantimicrobial surfactant-based dressing could disrupt existing biofilms by causing biofilm detachment. Prior to biofilm detachment, we demonstrated, using confocal laser scanning microscopy (CLSM), the dispersive effect of the nonantimicrobial surfactant-based wound dressing on the biofilm within 10 minutes of treatment. Furthermore, the non-antimicrobial surfactant-based wound dressing caused an increase in microbial flocculation/aggregation, important for microbial concentration. In conclusion, this nonantimicrobial surfactant-based wound dressing leads to the effective detachment and dispersion of in vitro biofilms. The use of surfactant-based wound dressings in a clinical setting may help to disrupt existing biofilm from wound tissue and may increase the action of antimicrobial treatment. © 2017 by the Wound Healing Society.

  3. Dressing wear time after breast reconstruction: study protocol for a randomized controlled trial

    PubMed Central

    2013-01-01

    Background One of the major risk variables for surgical site infection is wound management. Understanding infection risk factors for breast operations is essential in order to develop infection-prevention strategies and improve surgical outcomes. The aim of this trial is to assess the influence of dressing wear time on surgical site infection rates and skin colonization. Patients’ perception at self-assessment will also be analyzed. Methods/Design This is a two-arm randomized controlled trial. Two hundred breast cancer patients undergoing immediate or delayed breast reconstruction will be prospectively enrolled. Patients will be randomly allocated to group I (dressing removed on postoperative day one) or group II (dressing removed on postoperative day six). Surgical site infections will be defined by standard criteria from the Centers for Disease Control and Prevention (CDC). Skin colonization will be assessed by culture of samples collected at predefined time points. Patients will score dressing wear time with regard to safety, comfort and convenience. Discussion The evidence to support dressing standards for breast surgery wounds is empiric and scarce. CDC recommends protecting, with a sterile dressing for 24 to 48 hours postoperatively, a primarily closed incision, but there is no recommendation to cover this kind of incision beyond 48 hours, or on the appropriate time to shower or bathe with an uncovered incision. The results of the ongoing trial may support standard recommendations regarding dressing wear time after breast reconstruction. Trial registration ClinicalTrials.gov identifier: http://NCT01148823. PMID:23432779

  4. Influence of hydrophilic polymers on functional properties and wound healing efficacy of hydrocolloid based wound dressings.

    PubMed

    Jin, Sung Giu; Yousaf, Abid Mehmood; Kim, Kyeong Soo; Kim, Dong Wuk; Kim, Dong Shik; Kim, Jin Ki; Yong, Chul Soon; Youn, Yu Seok; Kim, Jong Oh; Choi, Han-Gon

    2016-03-30

    The purpose of this study was to investigate the influence of different hydrophilic polymers on the swelling, bioadhesion and mechanical strength of hydrocolloid wound dressings (HCDs) in order to provide an appropriate composition for a hydrocolloid wound dressing system. In this study, the HCDs were prepared with styrene-isoprene-styrene copolymer (SIS) and polyisobutylene (PIB) as the base using a hot melting method. Additionally, numerous SIS/PIB-based HCDs were prepared with six hydrophilic polymers, and their wound dressing properties were assessed. Finally, the wound healing efficacy of the selected formulations was compared to a commercial wound dressing. The swelling ratio, bioadhesive force and mechanical strengths of HCDs were increased in the order of sodium alginate>sodium CMC=poloxamer=HPMC>PVA=PVP, sodium alginate>sodium CMC=poloxamer>PVA>HPMC=PVP and sodium alginate≥PVA>PVP=HPMC=sodium CMC>poloxamer, respectively. Among the hydrophilic polymers tested, sodium alginate most enhanced the swelling capacity, bioadhesive force and mechanical strengths. Thus, the hydrophilic polymers played great role in the swelling, bioadhesion and mechanical strength of SIS/PIB-based HCDs. The HCD formulation composed of PIB, SIS, liquid paraffin and sodium alginate at the weight ratio of 20/25/12/43 gave better wound dressing properties and more excellent wound healing efficacy than the commercial wound dressing. Therefore, the novel HCD formulation could be a promising hydrocolloid system for wound dressings. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. A Wireless Electroceutical Dressing Lowers Cost of Negative Pressure Wound Therapy

    PubMed Central

    Ghatak, Piya Das; Schlanger, Richard; Ganesh, Kasturi; Lambert, Lynn; Gordillo, Gayle M.; Martinsek, Patsy; Roy, Sashwati

    2015-01-01

    Objective: To test whether the use of a wireless electroceutical dressing (WED) (Procellera®) in conjunction with a 5-day negative pressure wound therapy (NPWT) may reduce the number of dressing changes required per week with this therapy. Approach: At the Ohio State University Comprehensive Wound Center, chronic wound patients (n=30) undergoing NPWT were randomized into two arms following consent as approved by the institutional review board. The control arm received standard of care NPWT, where the dressing change was performed thrice a week. The test arm received the same care except that the WED was added as an interface layer and dressing change was limited to twice a week. Results: A reduced cost of care was achieved using the WED in conjunction with NPWT. Despite fewer dressing changes in wounds dressed with the WED, closure outcomes were comparable with no overt signs of any wound complication, including infection. The cost of NPWT care during the week was significantly lower (from $2918 to $2346) in the WED-treated group compared with patients in the control arm. Innovation: This work introduces a novel technology platform involving a WED, which may be used in conjunction with NPWT. If used as such, NPWT is effective in decreasing the frequency of dressing change and lowering the cost of care. Conclusion: This work points toward the benefit of using the WED combined with NPWT. A larger clinical trial investigating the cost-effectiveness of WED in wound care is warranted. PMID:26005596

  6. Technological parameters influence on the non-autoclaved foam concrete characteristics

    NASA Astrophysics Data System (ADS)

    Bartenjeva, Ekaterina; Mashkin, Nikolay

    2017-01-01

    Foam concretes are used as effective heat-insulating materials. The porous structure of foam concrete provides good insulating and strength properties that make them possible to be used as heat-insulating structural materials. Optimal structure of non-autoclaved foam concrete depends on both technological factors and properties of technical foam. In this connection, the possibility to manufacture heat-insulation structural foam concrete on a high-speed cavity plant with the usage of protein and synthetic foamers was estimated. This experiment was carried out using mathematical planning method, and in this case mathematical models were developed that demonstrated the dependence of operating performance of foam concrete on foaming and rotation speed of laboratory plant. The following material properties were selected for the investigation: average density, compressive strength, bending strength and thermal conductivity. The influence of laboratory equipment technological parameters on technical foam strength and foam stability coefficient in the cement paste was investigated, physical and mechanical properties of non-autoclaved foam concrete were defined based on investigated foam. As a result of investigation, foam concrete samples were developed with performance parameters ensuring their use in production. The mathematical data gathered demonstrated the dependence of foam concrete performance on the technological regime.

  7. Role of foam drainage in producing protein aggregates in foam fractionation.

    PubMed

    Li, Rui; Zhang, Yuran; Chang, Yunkang; Wu, Zhaoliang; Wang, Yanji; Chen, Xiang'e; Wang, Tao

    2017-10-01

    It is essential to obtain a clear understanding of the foam-induced protein aggregation to reduce the loss of protein functionality in foam fractionation. The major effort of this work is to explore the roles of foam drainage in protein aggregation in the entire process of foam fractionation with bovine serum albumin (BSA) as a model protein. The results show that enhancing foam drainage increased the desorption of BSA molecules from the gas-liquid interface and the local concentration of desorbed molecules in foam. Therefore, it intensified the aggregation of BSA in foam fractionation. Simultaneously, it also accelerated the flow of BSA aggregates from rising foam into the residual solution along with the drained liquid. Because enhancing foam drainage increased the relative content of BSA molecules adsorbed at the gas-liquid interface, it also intensified the aggregation of BSA during both the defoaming process and the storage of the foamate. Furthermore, enhancing foam drainage more readily resulted in the formation of insoluble BSA aggregates. The results are highly important for a better understanding of foam-induced protein aggregation in foam fractionation. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Enhanced rhamnolipids production via efficient foam-control using stop valve as a foam breaker.

    PubMed

    Long, Xuwei; Shen, Chong; He, Ni; Zhang, Guoliang; Meng, Qin

    2017-01-01

    In this study, a stop valve was used as a foam breaker for dealing with the massive overflowing foam in rhamnolipid fermentation. As found, a stop valve at its tiny opening could break over 90% of the extremely stable rhamnolipid foam into enriched liquid when foam flows through the sharp gap in valve. The efficient foam-control by the stop valve considerably improved the rhamnolipid fermentation and significantly enhanced the rhamnolipid productivity by 83% compared to the regular fermentation. This efficient foam breaking was mainly achieved by a high shear rate in combination with fast separation of air from the collapsed foam. Altogether, the stop valve possessed a great activity in breaking rhamnolipid foam, and the involving mechanism holds the potential for developing efficient foam breakers for industrial rhamnolipid fermentation. Copyright © 2016. Published by Elsevier Ltd.

  9. ZrP nanoplates based fire-fighting foams stabilizer

    NASA Astrophysics Data System (ADS)

    Zhang, Lecheng; Cheng, Zhengdong; Li, Hai

    2015-03-01

    Firefighting foam, as a significant innovation in fire protection, greatly facilitates extinguishments for liquid pool fire. Recently, with developments in LNG industry, high-expansion firefighting foams are also used for extinguishing LNG fire or mitigating LNG leakage. Foam stabilizer, an ingredient in fire-fighting foam, stabilizes foam bubbles and maintains desired foam volume. Conventional foam stabilizers are organic molecules. In this work, we developed a inorganic based ZrP (Zr(HPO4)2 .H2O, Zirconium phosphate) plates functionalized as firefighting foam stabilizer, improving firefighting foam performance under harsh conditions. Several tests were conducted to illustrate performance. The mechanism for the foam stabilization is also proposed. Artie McFerrin Department of Chemical Engineering, Texas A&M University, College Station, TX 77843, USA. Mary Kay O'Connor Process Safety Center, Texas A&M University, College Station, TX, 77843-3122

  10. Foam, Foam-resin composite and method of making a foam-resin composite

    NASA Technical Reports Server (NTRS)

    MacArthur, Doug E. (Inventor); Cranston, John A. (Inventor)

    1995-01-01

    This invention relates to a foam, a foam-resin composite and a method of making foam-resin composites. The foam set forth in this invention comprises a urethane modified polyisocyanurate derived from an aromatic amino polyol and a polyether polyol. In addition to the polyisocyanurate foam, the composite of this invention further contains a resin layer, wherein the resin may be epoxy, bismaleimide, or phenolic resin. Such resins generally require cure or post-cure temperatures of at least 350.degree. F.

  11. DEVELOPMENT OF A NEXT-GENERATION ANTIMICROBIAL WOUND DRESSING.

    PubMed

    Metcalf, Daniel; Parsons, David; Bowler, I Philip

    2016-03-01

    Delayed wound healing due to infection is a burden on healthcare systems, and the patient and caregiver alike. An emerging factor in infection and delayed healing is the presence development of biofilm in wounds. Biofilm is communities of microorganisms, protected by an extracellular matrix of slime in the wound, which can tolerate host defences and applied antimicrobials such as antibiotics or antimicrobial dressings. A growing evidence base exists suggesting that biofilm exists in a majority of chronic wounds, and can be a precursor to infection while causing delayed healing itself. In vivo models have demonstrated that the inflammatory, granulation and epithelialization processes of normal wound healing are impaired by biofilm presence. The challenge in the development of a new antimicrobial wound dressing was to make standard antimicrobial agents more effective against biofilm, and this was answered following extensive biofilm research and testing. A combination of metal chelator, surfactant and pH control displayed highly synergistic anti-biofilm action with 1.2% ionic silver in a carboxymethylcellulose dressing. Its effectiveness was challenged and proven in complex in vitro and in vivo wound biofilm models, followed by clinical safety and performance demonstrations in a 42-patient study and 113 clinical evaluations. Post-market surveillance was conducted on the commercially available dressing, and in a 112-case evaluation, the dressing was shown to effectively manage exudate and suspected biofilm while shifting difficult-to-heal wounds onto healing trajectories, after an average of 4 weeks of new dressing use in otherwise standard wound care protocols. This was accompanied by a low frequency of dressing related adverse events. In a second evaluation, clinical signs of infection and wound dimension data, before and after the evaluations, were also available. Following an average of 5.4 weeks of dressing use, all signs of clinical infection were reduced, from an average frequency of 36% to 21%. An average of 62% wound size reduction was achieved, with 90% of wounds reducing in size and 10 wounds healing completely. The new clinical evidence for this next-generation antimicrobial wound dressing suggests it is safe and effective at managing exudate, infection and biofilm, while it can shift established, stubborn wounds onto healing trajectories. The scientific rationale for this new dressing technology is supported by in vitro and in vivo evidence, so now further comparative, randomized and outcome-based clinical studies are required to fully understand the clinical and economic benefits this new dressing technology can bring.

  12. Use of a copolymer dressing on superficial and partial-thickness burns in a paediatric population.

    PubMed

    Everett, M; Massand, S; Davis, W; Burkey, B; Glat, P M

    2015-07-01

    Despite extensive research into the treatment of partial-thickness burns, to date there has not been the emergence of a preeminent modality. This pilot study, the first such study to be performed in a burn unit in the US, was designed to evaluate the efficacy and outcomes of the application of copolymer dressing (Suprathel; PolyMedics Innovations Corporation, Stuttgart, Germany) for both superficial and deeper partial-thickness burns. The copolymer dressing was used as a primary wound dressing to treat superficial and deep partial-thickness burns (average 5% total body surface area) in paediatric patients. Burns were debrided within 24 hours, at bedside, in the burn unit or in the operating room. The copolymer dressing was then applied directly to the wound and covered with a non-adherent second layer and an absorptive outer dressing. After discharge, patients were seen every 5-7 days until healed. Parameters evaluated included average hospital length of stay, average number of intravenous doses of narcotics administered, pain score at first follow-up visit, average time to complete re epithelialisation, incidence of burn wound infection, and patient/parent satisfaction on a 4-point scale. We also evaluated our experience with the dressing. Data were evaluated retrospectively under an Investigational Review Board approved protocol. Of the 17 patients assessed the average hospital length of stay was 1.4 days during which the average number of intravenous narcotic doses administered before copolymer dressing application was 1.5 and after was 0.1 doses. At the first follow-up visit, average pain score was 1.2 on a 10-point scale and the average time to re epithelialisation was 9.5 days. There was no incidence of burn wound infection. Patient/parent satisfaction was average of 3.66 on a 4-point scale. The staff had found that the self-adherence and elasticity of the dressing made it easy to apply and stay adherent, especially in areas of difficult contour. There were no readmissions for further debridement or skin grafting. Our experience shows that patients may be discharged shortly after the application of the copolymer dressing, with manageable pain scores and ease of use as determined by the caretakers high satisfaction. This new, fully synthetic copolymer dressing is easy to apply, does not require any additional antimicrobial coverage and may be used to successfully manage deeper partial-thickness burns, donor sites or burns in areas of contour, where many other dressings might not be considered or be appropriate. None declared.

  13. 12. Influence of Wound Dressing on the Fracture Healing Effect of Low-Intensity Pulsed Ultrasound (LIPUS).

    PubMed

    Naruse, Koji; Uchino, Masataka; Hirakawa, Noriko; Toyama, Masahiro; Miyajima, Genyo; Mukai, Manabu; Urabe, Ken; Uchida, Kentaro; Itoman, Moritoshi

    2016-08-01

    We have conducted a basic study on the influences on ultrasonic properties when LIPUS is applied through wound dressing. According to the results of ex vivo experiments conducted to date, LIPUS showed ultrasonic properties such as transmittance, coefficient of transmission, and a non-uniformity ratio through film wound dressing better than other wound dressing, and it was considered that LIPUS's effect for fracture healing was not influenced by film wound dressing. Then, we discussed the influence on the effect of LIPUS through film wound dressing. Thirty male 8-week-old Sprague-Dawley rats were used for the trial. After creating close transverse femoral fractures on the right legs of these 30 rats, they were divided into 3 groups of 10; LIPUS through wound dressing (Group A), LIPUS without wound dressing (Group B), and No LIPUS treatment (Group C). OPSITE Wound, which was thought to have the least influence on ultrasound properties, was used for this trial. Group A and B received LIPUS for 20 minutes a day from the first day after the fractures. LIPUS was generated from Teijin Pharma's device for a basic experiment. When treating Group A, the wound dressing was pasted on the ultrasound terminal in order to apply LIPUS through the dressing. We assessed the time-oriented morphological change of each group in anesthetized condition using simple radiographs on the 8th, 16th, and 24th day after the fractures. Six rats in Group A, 2 in Group B, and 1 in Group C died in anesthesia, and we discussed the remaining 4 rats in Group A, 8 in Group B, and 9 in Group C. We defined more than one teleost callus bridging as bone-union. We also counted a bone remodeling when we recognized the absorption of existing cortical bone and the transformation of new bone to cortical bone in simple radiographs. As a result, compared with Group C, we recognized that both bone union and remodeling accelerated remarkably in Group B, but not in Group A. It suggested that LIPUS through wound dressing had negative influences on both period shorting of fracture healing and bone remodeling. When LIPUS was conducted through film wound dressing, transmittance and coefficient of transmission were unchanged; however, the non-uniformity ratio changed slightly. The non-uniformity ratio of the ultrasound transducer had a significant influence on the effect of LIPUS on fracture healing.

  14. Adsorption of Toluene and Paraxylene from Aqueous Solution Using Pure and Iron Oxide Impregnated Carbon Nanotubes: Kinetics and Isotherms Study

    PubMed Central

    Abbas, Aamir; Ihsanullah; Al-Baghli, Nadhir A. H.

    2017-01-01

    Multiwall carbon nanotubes (CNTs) and iron oxide impregnated carbon nanotubes (CNTs-iron oxide) were investigated for the adsorption of hazardous toluene and paraxylene (p-xylene) from aqueous solution. Pure CNTs were impregnated with iron oxides nanoparticles using wet impregnation technique. Various characterization techniques including thermogravimetric analysis, scanning electron microscopy, elemental dispersion spectroscopy, X-ray diffraction, and nitrogen adsorption analysis were used to study the thermal degradation, surface morphology, purity, and surface area of the materials. Batch adsorption experiments show that iron oxide impregnated CNTs have higher degree of removal of p-xylene (i.e., 90%) compared with toluene (i.e., 70%), for soaking time 2 h, with pollutant initial concentration 100 ppm, at pH 6 and shaking speed of 200 rpm at 25°C. Pseudo-second-order model provides better fitting for the toluene and p-xylene adsorption. Langmuir and Freundlich isotherm models demonstrate good fitting for the adsorption data of toluene and p-xylene. PMID:28386208

  15. Exploratory development of foams from liquid crystal polymers

    NASA Technical Reports Server (NTRS)

    Chung, T. S.

    1985-01-01

    Two types of liquid crystal polymer (LCP) compositions were studied and evaluated as structural foam materials. One is a copolymer of 6-hydroxy-2-naphthoic acid, terephthalic acid, and p-acetoxyacetanilide (designed HNA/TA/AAA), and the other is a copolymer of p-hydroxybenzoic acid and 6-hydroxy-2-naphthoic acid (designated HBA/HNA). Experimental results showed that the extruded HNA/TA/AA foams have better mechanical quality and appearance than HBA/HNA foams. Heat treatment improved foam tensile strength and break elongation, but reduced their modulus. The injection molding results indicated that nitrogen foaming agents with a low-pressure process gave better void distribution in the injection molded LCP foams than those made by the conventional injection-molding machine and chemical blowing agents. However, in comparing LCP foams with other conventional plastic foams, HBA/HNA foams have better mechanical properties than foamed ABS and PS, but are comparable to PBT and inferior to polycarbonate foams, especially in heat-deflection temperature and impact resistance energy. These deficiencies are due to LCP molecules not having been fully oriented during the Union-Carbide low-pressure foaming process.

  16. Espresso coffee foam delays cooling of the liquid phase.

    PubMed

    Arii, Yasuhiro; Nishizawa, Kaho

    2017-04-01

    Espresso coffee foam, called crema, is known to be a marker of the quality of espresso coffee extraction. However, the role of foam in coffee temperature has not been quantitatively clarified. In this study, we used an automatic machine for espresso coffee extraction. We evaluated whether the foam prepared using the machine was suitable for foam analysis. After extraction, the percentage and consistency of the foam were measured using various techniques, and changes in the foam volume were tracked over time. Our extraction method, therefore, allowed consistent preparation of high-quality foam. We also quantitatively determined that the foam phase slowed cooling of the liquid phase after extraction. High-quality foam plays an important role in delaying the cooling of espresso coffee.

  17. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, Eric B.; Muller, Albert C.

    1984-01-01

    A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.

  18. The influence of FLiNaK salt impregnation on the mechanical properties of a 2D woven C/C composite

    NASA Astrophysics Data System (ADS)

    Zhang, Dongsheng; Xia, Huihao; Yang, Xinmei; Feng, Shanglei; Song, Jinliang; Zhou, Xingtai

    2017-03-01

    Impregnating of molten LiF-NaF-KF salt (LiF-NaF-KF: 46.5-11.5-42 mol%, FLiNaK) into a 2D woven C/C composite was performed at 650 °C under different pressure. The weight gain and mechanical properties change of the 2D woven C/C composite after FLiNaK salt impregnation were measured. The FLiNaK salt distribution into the 2D woven C/C composite was observed by X-ray computed tomography (X-ray CT) and scanning electron microscopy. The results showed that the weight gain of the 2D woven C/C composite increased with increasing impregnating pressure. In X-ray CT images, FLiNaK salt was distributed into the open pores and fissures among fiber bundles and neighboring plies. The interlaminar shear strength, compressive strength, and flexural strength of the 2D woven C/C composite increased with the increase of weight gain. The influence of FLiNaK salt impregnation on the mechanical properties was attributed to the coupling effect of re-densification of FLiNaK salt impregnation and residual stress formed in 2D woven C/C composite.

  19. The bactericidal activity of glutaraldehyde-impregnated polyurethane.

    PubMed

    Sehmi, Sandeep K; Allan, Elaine; MacRobert, Alexander J; Parkin, Ivan

    2016-10-01

    Although glutaraldehyde is known to be bactericidal in solution, its potential use to create novel antibacterial polymers suitable for use in healthcare environments has not been evaluated. Here, novel materials were prepared in which glutaraldehyde was either incorporated into polyurethane using a simple "swell-encapsulation-shrink" method (hereafter referred to as "glutaraldehyde-impregnated polyurethane"), or simply applied to the polymer surface (hereafter referred to as "glutaraldehyde-coated polyurethane"). The antibacterial activity of glutaraldehyde-impregnated and glutaraldehyde-coated polyurethane samples was tested against Escherichia coli and Staphylococcus aureus. Glutaraldehyde-impregnated polyurethane resulted in a 99.9% reduction in the numbers of E. coli within 2 h and a similar reduction of S. aureus within 1 h, whereas only a minimal reduction in bacterial numbers was observed when the biocide was bound to the polymer surface. After 15 days, however, the bactericidal activity of the impregnated material was substantially reduced presumably due to polymerization of glutaraldehyde. Thus, although glutaraldehyde retains antibacterial activity when impregnated into polyurethane, activity is not maintained for extended periods of time. Future work should examine the potential of chemical modification of glutaraldehyde and/or polyurethane to improve the useful lifespan of this novel antibacterial polymer. © 2016 The Authors. MicrobiologyOpen published by John Wiley & Sons Ltd.

  20. Generation of sclerosant foams by mechanical methods increases the foam temperature.

    PubMed

    Tan, Lulu; Wong, Kaichung; Connor, David; Fakhim, Babak; Behnia, Masud; Parsi, Kurosh

    2017-08-01

    Objective To investigate the effect of agitation on foam temperature. Methods Sodium tetradecyl sulphate and polidocanol were used. Prior to foam generation, the sclerosant and all constituent equipment were cooled to 4-25℃ and compared with cooling the sclerosant only. Foam was generated using a modified Tessari method. During foam agitation, the temperature change was measured using a thermocouple for 120 s. Results Pre-cooling all the constituent equipment resulted in a cooler foam in comparison with only cooling the sclerosant. A starting temperature of 4℃ produced average foam temperatures of 12.5 and 13.2℃ for sodium tetradecyl sulphate and polidocanol, respectively. It was also found that only cooling the liquid sclerosant provided minimal cooling to the final foam temperature, with the temperature 20 and 20.5℃ for sodium tetradecyl sulphate and polidocanol, respectively. Conclusion The foam generation process has a noticeable impact on final foam temperature and needs to be taken into consideration when creating foam.

  1. Infiltrated carbon foam composites

    NASA Technical Reports Server (NTRS)

    Lucas, Rick D. (Inventor); Danford, Harry E. (Inventor); Plucinski, Janusz W. (Inventor); Merriman, Douglas J. (Inventor); Blacker, Jesse M. (Inventor)

    2012-01-01

    An infiltrated carbon foam composite and method for making the composite is described. The infiltrated carbon foam composite may include a carbonized carbon aerogel in cells of a carbon foam body and a resin is infiltrated into the carbon foam body filling the cells of the carbon foam body and spaces around the carbonized carbon aerogel. The infiltrated carbon foam composites may be useful for mid-density ablative thermal protection systems.

  2. In vitro study of transverse strength of fiber reinforced composites.

    PubMed

    Mosharraf, R; Hashemi, Z; Torkan, S

    2011-01-01

    Reinforcement with fiber is an effective method for considerable improvement in flexural properties of indirect composite resin restorations. The aim of this in-vitro study was to compare the transverse strength of composite resin bars reinforced with pre-impregnated and non-impregnated fibers. Thirty six bar type composite resin specimens (3×2×25 mm) were constructed in three groups. The first group was the control group (C) without any fiber reinforcement. The specimens in the second group (P) were reinforced with pre-impregnated fibers and the third group (N) with non-impregnated fibers. These specimens were tested by the three-point bending method to measure primary transverse strength. Data were statistically analyzed with one way ANOVA and Tukey's tests. There was a significant difference among the mean primary transverse strength in the three groups (P<0.001). The post-hoc (Tukey) test showed that there was a significant difference between the pre-impregnated and control groups in their primary transverse strength (P<0.001). Regarding deflection, there was also a significant difference among the three groups (P=0.001). There were significant differences among the mean deflection of the control group and two other groups (P(C&N)<.001 and P(C&P)=.004), but there was no significant difference between the non-and pre-impregnated groups (P(N&P)=.813). Within the limitations of this study, it was concluded that reinforcement with fiber considerably increased the transverse strength of composite resin specimens, but impregnation of the fiber used implemented no significant difference in the transverse strength of composite resin samples.

  3. Foam property tests to evaluate the potential for longwall shield dust control.

    PubMed

    Reed, W R; Beck, T W; Zheng, Y; Klima, S; Driscoll, J

    2018-01-01

    Tests were conducted to determine properties of four foam agents for their potential use in longwall mining dust control. Foam has been tried in underground mining in the past for dust control and is currently being reconsidered for use in underground coal longwall operations in order to help those operations comply with the Mine Safety and Health Administration's lower coal mine respirable dust standard of 1.5 mg/m 3 . Foams were generated using two different methods. One method used compressed air and water pressure to generate foam, while the other method used low-pressure air generated by a blower and water pressure using a foam generator developed by the U.S. National Institute for Occupational Safety and Health. Foam property tests, consisting of a foam expansion ratio test and a water drainage test, were conducted to classify foams. Compressed-air-generated foams tended to have low expansion ratios, from 10 to 19, with high water drainage. Blower-air-generated foams had higher foam expansion ratios, from 30 to 60, with lower water drainage. Foams produced within these ranges of expansion ratios are stable and potentially suitable for dust control. The test results eliminated two foam agents for future testing because they had poor expansion ratios. The remaining two foam agents seem to have properties adequate for dust control. These material property tests can be used to classify foams for their potential use in longwall mining dust control.

  4. Foam property tests to evaluate the potential for longwall shield dust control

    PubMed Central

    Reed, W.R.; Beck, T.W.; Zheng, Y.; Klima, S.; Driscoll, J.

    2018-01-01

    Tests were conducted to determine properties of four foam agents for their potential use in longwall mining dust control. Foam has been tried in underground mining in the past for dust control and is currently being reconsidered for use in underground coal longwall operations in order to help those operations comply with the Mine Safety and Health Administration’s lower coal mine respirable dust standard of 1.5 mg/m3. Foams were generated using two different methods. One method used compressed air and water pressure to generate foam, while the other method used low-pressure air generated by a blower and water pressure using a foam generator developed by the U.S. National Institute for Occupational Safety and Health. Foam property tests, consisting of a foam expansion ratio test and a water drainage test, were conducted to classify foams. Compressed-air-generated foams tended to have low expansion ratios, from 10 to 19, with high water drainage. Blower-air-generated foams had higher foam expansion ratios, from 30 to 60, with lower water drainage. Foams produced within these ranges of expansion ratios are stable and potentially suitable for dust control. The test results eliminated two foam agents for future testing because they had poor expansion ratios. The remaining two foam agents seem to have properties adequate for dust control. These material property tests can be used to classify foams for their potential use in longwall mining dust control. PMID:29416179

  5. Multiscale Analysis of Open-Cell Aluminum Foam for Impact Energy Absorption

    NASA Astrophysics Data System (ADS)

    Kim, Ji Hoon; Kim, Daeyong; Lee, Myoung-Gyu; Lee, Jong Kook

    2016-09-01

    The energy-absorbing characteristics of crash members in automotive collision play an important role in controlling the amount of damage to the passenger compartment. Aluminum foams have high strength-to-weight ratio and high deformability, thus good crashworthiness is expected while maintaining or even saving weights when foams are implemented in crash members. In order to investigate the effect of the open-cell aluminum foam fillers on impact performance and weight saving, a multiscale framework for evaluating the crashworthiness of aluminum foam-filled members is used. To circumvent the difficulties of mechanical tests on foams, a micromechanical model of the aluminum foam is constructed using the x-ray micro tomography and virtual tests are conducted for the micromechanical model to characterize the behavior of the foam. In the macroscale, the aluminum foam is represented by the crushable foam constitutive model, which is then incorporated into the impact test simulation of the foam-filled crash member. The multiscale foam-filled crash member model was validated for the high-speed impact test, which confirms that the material model characterized by the micromechanical approach represents the behavior of the open-cell foam under impact loading well. Finally, the crash member design for maximizing the energy absorption is discussed by investigating various designs from the foam-only structure to the hollow tube structure. It was found that the foam structure absorbs more energy than the hollow tube or foam-filled structure with the same weight.

  6. Chlorhexidine-impregnated cloths to prevent skin and soft-tissue infection in Marine recruits: a cluster-randomized, double-blind, controlled effectiveness trial.

    PubMed

    Whitman, Timothy J; Herlihy, Rachel K; Schlett, Carey D; Murray, Patrick R; Grandits, Greg A; Ganesan, Anuradha; Brown, Maya; Mancuso, James D; Adams, William B; Tribble, David R

    2010-12-01

    Community-associated methicillin-resistant Staphylococcus aureus (CA-MRSA) causes skin and soft-tissue infection (SSTI) in military recruits. To evaluate the effectiveness of 2% chlorhexidine gluconate (CHG)-impregnated cloths in reducing rates of SSTI and S. aureus colonization among military recruits. A cluster-randomized (by platoon), double-blind, controlled effectiveness trial. Marine Officer Candidate School, Quantico, Virginia, 2007. Military recruits. Application of CHG-impregnated or control (Comfort Bath; Sage) cloths applied over entire body thrice weekly. Recruits were monitored daily for SSTI. Baseline and serial nasal and/or axillary swabs were collected to assess S. aureus colonization. Of 1,562 subjects enrolled, 781 (from 23 platoons) underwent CHG-impregnated cloth application and 781 (from 21 platoons) underwent control cloth application. The rate of compliance (defined as application of 50% or more of wipes) at 2 weeks was similar (CHG group, 63%; control group, 67%) and decreased over the 6-week period. The mean 6-week SSTI rate in the CHG-impregnated cloth group was 0.094, compared with 0.071 in the control group (analysis of variance model rate difference, 0.025  ± 0.016; P = .14). At baseline, 43% of subjects were colonized with methicillin-susceptible S. aureus (MSSA), and 2.1% were colonized with MRSA. The mean incidence of colonization with MSSA was 50% and 61% (P = .026) and with MRSA was 2.6% and 6.0% (P = .034) for the CHG-impregnated and control cloth groups, respectively. CHG-impregnated cloths applied thrice weekly did not reduce rates of SSTI among recruits. S. aureus colonization rates increased in both groups but to a lesser extent in those assigned to the CHG-impregnated cloth intervention. Antecedent S. aureus colonization was not a risk factor for SSTI. Additional studies are needed to identify effective measures for preventing SSTI among military recruits. ClinicalTrials.gov identifier: NCT00475930.

  7. Professional Characteristics Communicated by Formal versus Casual Workplace Attire

    ERIC Educational Resources Information Center

    Cardon, Peter W.; Okoro, Ephraim A.

    2009-01-01

    Employees are frequently advised to dress for success to build their careers. From the corporate perspective, employees who are well dressed are believed to form better impressions with colleagues, clients, and customers. Many companies create dress codes in order to gain the benefits of a professionally appearing workforce. Developing effective…

  8. Identification of Workplace Dress by Low-Income Job Seekers

    ERIC Educational Resources Information Center

    Saiki, Diana

    2013-01-01

    The author examined how low-income job seekers participating in a workplace dress program identified traditional business and business casual dress. Seventy low-income job seekers identified clothing items as traditional business (e.g., suits, ties), similar to identifications made by professionals and image consultants in previous literature.…

  9. Dress Codes and Uniforms.

    ERIC Educational Resources Information Center

    Lumsden, Linda; Miller, Gabriel

    2002-01-01

    Students do not always make choices that adults agree with in their choice of school dress. Dress-code issues are explored in this Research Roundup, and guidance is offered to principals seeking to maintain a positive school climate. In "Do School Uniforms Fit?" Kerry White discusses arguments for and against school uniforms and summarizes the…

  10. Counterconformity: An Attribution Model of Adolescents' Uniqueness-Seeking Behaviors in Dressing

    ERIC Educational Resources Information Center

    Ling, I-Ling

    2008-01-01

    This article explores how an attribution model will illustrate uniqueness-seeking behavior in dressing in the Taiwanese adolescent subculture. The study employed 443 senior high school students. Results show that the tendency of uniqueness-seeking behavior in dressing is moderate. However, using cluster analysis to segment the counterconformity…

  11. 21 CFR 878.4018 - Hydrophilic wound dressing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hydrophilic wound dressing. 878.4018 Section 878.4018 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing...

  12. 21 CFR 878.4018 - Hydrophilic wound dressing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hydrophilic wound dressing. 878.4018 Section 878.4018 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing...

  13. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...

  14. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...

  15. 21 CFR 878.4018 - Hydrophilic wound dressing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hydrophilic wound dressing. 878.4018 Section 878.4018 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing...

  16. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...

  17. 9 CFR 108.9 - Dressing rooms and other facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Dressing rooms and other facilities. 108.9 Section 108.9 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT... REQUIREMENTS FOR LICENSED ESTABLISHMENTS § 108.9 Dressing rooms and other facilities. Each licensed...

  18. Advanced Hemostatic Dressing Development Program: Animal Model Selection Criteria and Results of a Study of Nine Hemostatic Dressings in a Model of Severe Large Venous Hemorrhage and Hepatic Injury in Swine

    DTIC Science & Technology

    2003-09-01

    Pharmaceuticals, Inc. (Westlake, OH), submitted the Hemarrest dressing. This dressing was a thin, sheet-like pad with a mixture of epsilon aminocaproic acid ...chloric acid salt purified bovine corium collagen. It was prepared in a compacted nonwoven web form (7.0 7.0 cm). Ethicon, Inc. (Somerville, NJ...may be related to enhanced platelet procoagulant activity and annexin V binding.46 Another derivative of gallic acid , bis- muth subgallate, appears to

  19. An evaluation of a silicone adhesive shaped heel dressing.

    PubMed

    Hampton, Sylvie

    Tissue breakdown is complex and involves many factors. Pressure ulcer development in the heels is subject to extrinsic factors such as pressure, shear, friction and moisture. The heels are the most common sites for friction and shear damage, which can lead to blistering, skin erosion and tissue breakdown (Grey et al, 2006). To address the issues of wounds that are painful on dressing removal and friable skin, Smith & Nephew has introduced a soft silicone adhesive dressing to its Allevyn dressing range. Silicone does not adhere to wounded areas and can be removed gently without trauma to the periwound area. This paper discusses the findings of a 20-patient multi-site evaluation examining the performance and acceptability of Allevyn Gentle Border Heel dressing in the management of heel wounds.

  20. The use of prophylactic dressings in the prevention of pressure ulcers: a literature review.

    PubMed

    Cornish, Lynn

    2017-06-02

    Pressure ulcers pose a significant burden to both patients and health care resources. There are an increasing number of studies that have examined the use of prophylactic dressings, and their ability to redistribute pressure and protect the skin from shear and friction damage. This literature review examines six studies conducted on this controversial subject. Brindle and Wegelin ( 2012 ; Chaiken, 2012 ; Cubit et al, 2012 ; Santamaria et al, 2012) all examined the role of dressings to prevent pressure ulcers, and Call et al (2013a ; 2013b ), conducted in vitro research into the mode of dressings. Current research suggests that while further research is required, the use of prophylactic dressings have a place alongside standard measures, in helping to prevent pressure, shear and friction damage.