Immunisation registers in Italy: a patchwork of computerisation.
Alfonsi, V; D'Ancona, F; Rota, M C; Giambi, C; Ranghiasci, A; Iannazzo, S
2012-04-26
In Italy, the 21 regional health authorities are in charge of organising and implementing their own vaccination strategy, based on the national vaccine plan. Immunisation coverage varies greatly among the regions for certain vaccines. Efforts to increase childhood immunisation coverage have included initiatives to develop and implement computerised immunisation registers in as many regions as possible. We undertook a cross-sectional online survey in July 2011 to provide an updated picture of the use, heterogeneity and main functions of different computerised immunisation registers used in the Italian regions and to understand the flow of information from local health units to the regional authorities and to the Ministry of Health. Comparing current data with those obtained in 2007, a substantial improvement is evident. A total of 15 regions are fully computerised (previously nine), with 83% of local health units equipped with a computerised register (previously 70%). Eight of the 15 fully computerised regions use the same software, simplifying data sharing. Only four regions are able to obtain data in real time from local health units. Despite the progress made, the capacity to monitor vaccination coverage and to exchange data appears still limited.
Matsuda, Yasuhiro; Morimoto, Tsubasa; Furukawa, Shunichi; Sato, Sayaka; Hatsuse, Norifumi; Iwata, Kazuhiko; Kimura, Mieko; Kishimoto, Toshifumi; Ikebuchi, Emi
2018-04-01
Devising new methods to improve neurocognitive impairment through cognitive remediation is an important research goal. We developed an original computer programme termed the Japanese Cognitive Rehabilitation Programme for Schizophrenia (JCORES) that provides cognitive practice across a broad range of abilities. The current study examined for the first time whether a cognitive remediation programme, including both computerised cognitive training using JCORES and group intervention such as enhancing meta-cognition and teaching strategies, is more effective than treatment as usual for improving neurocognitive and social functioning. Sixty-two outpatients with schizophrenia were randomised to either a cognitive remediation group or a control group. Participants engaged in two computerised cognitive training sessions and one group meeting per week for 12 weeks. The average number of total sessions attended (computerised cognitive practice + group intervention) was 32.3 (89.7%). The cognitive remediation group showed significantly more improvements in verbal memory, composite score of the Brief Assessment of Cognition in Schizophrenia, Japanese version (BACS-J), and general psychopathology on the Positive and Negative Syndrome Scale (PANSS) than the control group. These findings demonstrate that a cognitive remediation programme is feasible in Japan and is a more effective way to improve neurocognitive functioning and psychiatric symptoms.
Do Computerised Training Programmes Designed to Improve Working Memory Work?
ERIC Educational Resources Information Center
Apter, Brian J. B.
2012-01-01
A critical review of working memory training research during the last 10 years is provided. Particular attention is given to research that has attempted to investigate the efficacy of commercially marketed computerised training programmes such as "Cogmed" and "Jungle Memory". Claimed benefits are questioned on the basis that research methodologies…
Dalton, Kieran; O'Brien, Gary; O'Mahony, Denis; Byrne, Stephen
2018-06-08
computerised interventions have been suggested as an effective strategy to reduce potentially inappropriate prescribing (PIP) for hospitalised older adults. This systematic review and meta-analysis examined the evidence for efficacy of computerised interventions designed to reduce PIP in this patient group. an electronic literature search was conducted using eight databases up to October 2017. Included studies were controlled trials of computerised interventions aiming to reduce PIP in hospitalised older adults (≥65 years). Risk of bias was assessed using Cochrane's Effective Practice and Organisation of Care criteria. of 653 records identified, eight studies were included-two randomised controlled trials, two interrupted time series analysis studies and four controlled before-after studies. Included studies were mostly at a low risk of bias. Overall, seven studies showed either a statistically significant reduction in the proportion of patients prescribed a potentially inappropriate medicine (PIM) (absolute risk reduction {ARR} 1.3-30.1%), or in PIMs ordered (ARR 2-5.9%). However, there is insufficient evidence thus far to suggest that these interventions can routinely improve patient-related outcomes. It was only possible to include three studies in the meta-analysis-which demonstrated that intervention patients were less likely to be prescribed a PIM (odds ratio 0.6; 95% CI 0.38, 0.93). No computerised intervention targeting potential prescribing omissions (PPOs) was identified. this systematic review concludes that computerised interventions are capable of statistically significantly reducing PIMs in hospitalised older adults. Future interventions should strive to target both PIMs and PPOs, ideally demonstrating both cost-effectiveness data and clinically significant improvements in patient-related outcomes.
Derikx, Joep P M; Erdkamp, Frans L G; Hoofwijk, A G M
2013-01-01
An electronic health record (EHR) should provide 4 key functionalities: (a) documenting patient data; (b) facilitating computerised provider order entry; (c) displaying the results of diagnostic research; and (d) providing support for healthcare providers in the clinical decision-making process.- Computerised provider order entry into the EHR enables the electronic receipt and transfer of orders to ancillary departments, which can take the place of handwritten orders.- By classifying the computer provider order entries according to disorders, digital care pathways can be created. Such care pathways could result in faster and improved diagnostics.- Communicating by means of an electronic instruction document that is linked to a computerised provider order entry facilitates the provision of healthcare in a safer, more efficient and auditable manner.- The implementation of a full-scale EHR has been delayed as a result of economic, technical and legal barriers, as well as some resistance by physicians.
Practices to prevent venous thromboembolism: a brief review
Lau, Brandyn D; Haut, Elliott R
2014-01-01
Background Venous thromboembolism (VTE) is a common cause of preventable harm for hospitalised patients. Over the past decade, numerous intervention types have been implemented in attempts to improve the prescription of VTE prophylaxis in hospitals, with varying degrees of success. We reviewed key articles to assess the efficacy of different types of interventions to improve prescription of VTE prophylaxis for hospitalised patients. Methods We conducted a search of MEDLINE for key studies published between 2001 and 2012 of interventions employing education, paper based tools, computerised tools, real time audit and feedback, or combinations of intervention types to improve prescription of VTE prophylaxis for patients in hospital settings. Process outcomes of interest were prescription of any VTE prophylaxis and best practice VTE prophylaxis. Clinical outcomes of interest were any VTE and potentially preventable VTE, defined as VTE occurring in patients not prescribed appropriate prophylaxis. Results 16 articles were included in this review. Two studies employed education only, four implemented paper based tools, four used computerised tools, two evaluated audit and feedback strategies, and four studies used combinations of intervention types. Individual modalities result in improved prescription of VTE prophylaxis; however, the greatest and most sustained improvements were those that combined education with computerised tools. Conclusions Many intervention types have proven effective to different degrees in improving VTE prevention. Provider education is likely a required additional component and should be combined with other intervention types. Active mandatory tools are likely more effective than passive ones. Information technology tools that are well integrated into provider workflow, such as alerts and computerised clinical decision support, can improve best practice prophylaxis use and prevent patient harm resulting from VTE. PMID:23708438
Musiat, Peter; Goldstone, Philip; Tarrier, Nicholas
2014-04-11
E-mental health and m-mental health include the use of technology in the prevention, treatment and aftercare of mental health problems. With the economical pressure on mental health services increasing, e-mental health and m-mental health could bridge treatment gaps, reduce waiting times for patients and deliver interventions at lower costs. However, despite the existence of numerous effective interventions, the transition of computerised interventions into care is slow. The aim of the present study was to investigate the acceptability of e-mental health and m-mental health in the general population. An advisory group of service users identified dimensions that potentially influence an individual's decision to engage with a particular treatment for mental health problems. A large sample (N = 490) recruited through email, flyers and social media was asked to rate the acceptability of different treatment options for mental health problems on these domains. Results were analysed using repeated measures MANOVA. Participants rated the perceived helpfulness of an intervention, the ability to motivate users, intervention credibility, and immediate access without waiting time as most important dimensions with regard to engaging with a treatment for mental health problems. Participants expected face-to-face therapy to meet their needs on most of these dimensions. Computerised treatments and smartphone applications for mental health were reported to not meet participants' expectations on most domains. However, these interventions scored higher than face-to-face treatments on domains associated with the convenience of access. Overall, participants reported a very low likelihood of using computerised treatments for mental health in the future. Individuals in this study expressed negative views about computerised self-help intervention and low likelihood of use in the future. To improve the implementation and uptake, policy makers need to improve the public perception of such interventions.
2014-01-01
Background E-mental health and m-mental health include the use of technology in the prevention, treatment and aftercare of mental health problems. With the economical pressure on mental health services increasing, e-mental health and m-mental health could bridge treatment gaps, reduce waiting times for patients and deliver interventions at lower costs. However, despite the existence of numerous effective interventions, the transition of computerised interventions into care is slow. The aim of the present study was to investigate the acceptability of e-mental health and m-mental health in the general population. Methods An advisory group of service users identified dimensions that potentially influence an individual’s decision to engage with a particular treatment for mental health problems. A large sample (N = 490) recruited through email, flyers and social media was asked to rate the acceptability of different treatment options for mental health problems on these domains. Results were analysed using repeated measures MANOVA. Results Participants rated the perceived helpfulness of an intervention, the ability to motivate users, intervention credibility, and immediate access without waiting time as most important dimensions with regard to engaging with a treatment for mental health problems. Participants expected face-to-face therapy to meet their needs on most of these dimensions. Computerised treatments and smartphone applications for mental health were reported to not meet participants’ expectations on most domains. However, these interventions scored higher than face-to-face treatments on domains associated with the convenience of access. Overall, participants reported a very low likelihood of using computerised treatments for mental health in the future. Conclusions Individuals in this study expressed negative views about computerised self-help intervention and low likelihood of use in the future. To improve the implementation and uptake, policy makers need to improve the public perception of such interventions. PMID:24725765
Computerised CBT for depressed adolescents: Randomised controlled trial.
Smith, Patrick; Scott, Rebecca; Eshkevari, Ertimiss; Jatta, Fatoumata; Leigh, Eleanor; Harris, Victoria; Robinson, Alex; Abeles, Paul; Proudfoot, Judy; Verduyn, Chrissie; Yule, William
2015-10-01
Depression in adolescents is a common and impairing problem. Effective psychological therapies for depression are not accessed by most adolescents. Computerised therapy offers huge potential for improving access to treatment. To test the efficacy of Stressbusters, a Computerised-CBT (C-CBT) programme for depression in young people. Multi-site, schools-based, RCT of C-CBT compared to Waiting List, for young people (N = 112; aged 12-16) with significant symptoms of depression, using multiple-informants (adolescents, parents, teachers), with follow-up at 3 and 6 months. Relative to being on a Waiting List, C-CBT was associated with statistically significant and clinically meaningful improvements in symptoms of depression and anxiety according to adolescent self-report; and with a trend towards improvements in depression and anxiety according to parent-report. Improvements were maintained at follow-up. Treatment gains were similar for boys and girls across the participating age range. Treatment effect was partially mediated by changes in ruminative thinking. Teachers rated adolescents as having few emotional or behavioural problems, both before and after intervention. C-CBT had no detectable effect on academic attainment. In the month after intervention, young people who received C-CBT had significantly fewer absences from school than those on the Waiting List. C-CBT shows considerable promise for the treatment of mild-moderate depression in adolescents. Copyright © 2015 Elsevier Ltd. All rights reserved.
[A computerised clinical decision-support system for the management of depression in Primary Care].
Aragonès, Enric; Comín, Eva; Cavero, Myriam; Pérez, Víctor; Molina, Cristina; Palao, Diego
Despite its clinical relevance and its importance as a public health problem, there are major gaps in the management of depression. Evidence-based clinical guidelines are useful to improve processes and clinical outcomes. In order to make their implementation easier these guidelines have been transformed into computerised clinical decision support systems. In this article, a description is presented on the basics and characteristics of a new computerised clinical guideline for the management of major depression, developed in the public health system in Catalonia. This tool helps the clinician to establish reliable and accurate diagnoses of depression, to choose the best treatment a priori according to the disease and the patient characteristics. It also emphasises the importance of systematic monitoring to assess the clinical course, and to adjust therapeutic interventions to the patient's needs at all times. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Mazza, Danielle; Pearce, Christopher; Turner, Lyle Robert; De Leon-Santiago, Maria; McLeod, Adam; Ferriggi, Jason; Shearer, Marianne
2016-07-04
The Melbourne East MonAsh GeNeral PracticE DaTabase (MAGNET) research platform was launched in 2013 to provide a unique data source for primary care and health services research in Australia. MAGNET contains information from the computerised records of 50 participating general practices and includes data from the computerised medical records of more than 1,100,000 patients. The data extracted is patient-level episodic information and includes a variety of fields related to patient demographics and historical clinical information, along with the characteristics of the participating general practices. While there are limitations to the data that is currently available, the MAGNET research platform continues to investigate other avenues for improving the breadth and quality of data, with the aim of providing a more comprehensive picture of primary care in Australia.
Barken, Tina Lien; Thygesen, Elin; Söderhamn, Ulrika
2017-12-28
Telemedicine is changing traditional nursing care, and entails nurses performing advanced and complex care within a new clinical environment, and monitoring patients at a distance. Telemedicine practice requires complex disease management, advocating that the nurses' reasoning and decision-making processes are supported. Computerised decision support systems are being used increasingly to assist reasoning and decision-making in different situations. However, little research has focused on the clinical reasoning of nurses using a computerised decision support system in a telemedicine setting. Therefore, the objective of the study is to explore the process of telemedicine nurses' clinical reasoning when using a computerised decision support system for the management of patients with chronic obstructive pulmonary disease. The factors influencing the reasoning and decision-making processes were investigated. In this ethnographic study, a combination of data collection methods, including participatory observations, the think-aloud technique, and a focus group interview was employed. Collected data were analysed using qualitative content analysis. When telemedicine nurses used a computerised decision support system for the management of patients with complex, unstable chronic obstructive pulmonary disease, two categories emerged: "the process of telemedicine nurses' reasoning to assess health change" and "the influence of the telemedicine setting on nurses' reasoning and decision-making processes". An overall theme, termed "advancing beyond the system", represented the connection between the reasoning processes and the telemedicine work and setting, where being familiar with the patient functioned as a foundation for the nurses' clinical reasoning process. In the telemedicine setting, when supported by a computerised decision support system, nurses' reasoning was enabled by the continuous flow of digital clinical data, regular video-mediated contact and shared decision-making with the patient. These factors fostered an in-depth knowledge of the patients and acted as a foundation for the nurses' reasoning process. Nurses' reasoning frequently advanced beyond the computerised decision support system recommendations. Future studies are warranted to develop more accurate algorithms, increase system maturity, and improve the integration of the digital clinical information with clinical experiences, to support telemedicine nurses' reasoning process.
[Survey on computerized immunization registries in Italy].
Alfonsi, V; D'Ancona, F; Ciofi degli Atti, M L
2008-01-01
Computerized immunization registries are essential for conducting and monitoring vaccination programs. In fact, they enable to improve vaccine offering to target population, generating needed-immunization lists and assessing levels of vaccination coverage. In 2007, a national survey on immunization registries was conducted in Italy. In February 2007, all the 21 Regional Health Authorities (RHAs) completed and returned an ad hoc questionnaire. In June 2007, RHAs were further contacted by telephone in order to verify and update the information provided in questionnaires. In 9 Italian Regions (42.8%), vaccination registries are computerized in all Local Health Units (LHUs). In five of these Regions, all LHUs use the same software, while in the remaining four Regions, different softwares are in use. In six additional Regions (28.6%), only some LHUs use computerized immunization registries (range 61.5%-95%). In the remaining 6 Regions (28.6%), which are all in Southern Italy, there are no computerised immunization registries at all. In total, computerised immunization registries cover 126/180 Italian LHUs (70%); in 76/126 (60%) of these LUHs, immunization registries are linked with population registries. This survey shows the need to improve the implementation of computerised immunization registries in Italy, especially in Southern Regions.
Westbrook, J I; Georgiou, A; Dimos, A; Germanos, T
2006-01-01
Objective To assess the impact of a computerised pathology order entry system on laboratory turnaround times and test ordering within a teaching hospital. Methods A controlled before and after study compared test assays ordered from 11 wards two months before (n = 97 851) and after (n = 113 762) the implementation of a computerised pathology order entry system (Cerner Millennium Powerchart). Comparisons were made of laboratory turnaround times, frequency of tests ordered and specimens taken, proportions of patients having tests, average number per patient, and percentage of gentamicin and vancomycin specimens labelled as random. Results Intervention wards experienced an average decrease in turnaround of 15.5 minutes/test assay (range 73.8 to 58.3 minutes; p<0.001). Reductions were significant for prioritised and non‐prioritised tests, and for those done within and outside business hours. There was no significant change in the average number of tests (p = 0.228), or specimens per patient (p = 0.324), and no change in turnaround time for the control ward (p = 0.218). Use of structured order screens enhanced data provided to laboratories. Removing three test assays from the liver function order set resulted in significantly fewer of these tests being done. Conclusions Computerised order entry systems are an important element in achieving faster test results. These systems can influence test ordering patterns through structured order screens, manipulation of order sets, and analysis of real time data to assess the impact of such changes, not possible with paper based systems. The extent to which improvements translate into improved patient outcomes remains to be determined. A potentially limiting factor is clinicians' capacity to respond to, and make use of, faster test results. PMID:16461564
Streiff, Michael B; Carolan, Howard T; Hobson, Deborah B; Kraus, Peggy S; Holzmueller, Christine G; Demski, Renee; Lau, Brandyn D; Biscup-Horn, Paula; Pronovost, Peter J
2012-01-01
Problem Venous thromboembolism (VTE) is a common cause of potentially preventable mortality, morbidity, and increased medical costs. Risk-appropriate prophylaxis can prevent most VTE events, but only a small fraction of patients at risk receive this treatment. Design Prospective quality improvement programme. Setting Johns Hopkins Hospital, Baltimore, Maryland, USA. Strategies for change A multidisciplinary team established a VTE Prevention Collaborative in 2005. The collaborative applied the four step TRIP (translating research into practice) model to develop and implement a mandatory clinical decision support tool for VTE risk stratification and risk-appropriate VTE prophylaxis for all hospitalised adult patients. Initially, paper based VTE order sets were implemented, which were then converted into 16 specialty-specific, mandatory, computerised, clinical decision support modules. Key measures for improvement VTE risk stratification within 24 hours of hospital admission and provision of risk-appropriate, evidence based VTE prophylaxis. Effects of change The VTE team was able to increase VTE risk assessment and ordering of risk-appropriate prophylaxis with paper based order sets to a limited extent, but achieved higher compliance with a computerised clinical decision support tool and the data feedback which it enabled. Risk-appropriate VTE prophylaxis increased from 26% to 80% for surgical patients and from 25% to 92% for medical patients in 2011. Lessons learnt A computerised clinical decision support tool can increase VTE risk stratification and risk-appropriate VTE prophylaxis among hospitalised adult patients admitted to a large urban academic medical centre. It is important to ensure the tool is part of the clinician’s normal workflow, is mandatory (computerised forcing function), and offers the requisite modules needed for every clinical specialty. PMID:22718994
Laing, G L; Bruce, J L; Aldous, C; Clarke, D L
2014-01-01
The Pietermaritzburg Metropolitan Trauma Service formerly lacked a robust computerised trauma registry. This made surgical audit difficult for the purpose of quality of care improvement and development. We aimed to design, construct and implement a computerised trauma registry within our service. Twelve months following its implementation, we sought to examine and report on the quality of the registry. Formal ethical approval to maintain a computerised trauma registry was obtained prior to undertaking any design and development. Appropriate commercial software was sourced to develop this project. The registry was designed as a flat file. A flat file is a plain text or mixed text and binary file which usually contains one record per line or physical record. Thereafter the registry file was launched onto a secure server. This provided the benefits of access security and automated backups. Registry training was provided to clients by the developer. The exercise of data capture was then integrated into the process of service delivery, taking place at the endpoint of patient care (discharge, transfer or death). Twelve months following its implementation, the compliance rates of data entry were measured. The developer of this project managed to design, construct and implement an electronic trauma registry into the service. Twelve months following its implementation the data were extracted and audited to assess the quality. A total of 2640 patient entries were captured onto the registry. Compliance rates were in the order of eighty percent and client satisfaction rates were high. A number of deficits were identified. These included the omission of weekend discharges and underreporting of deaths. The construction and implementation of the computerised trauma registry was the beginning of an endeavour to continue improvements in the quality of care within our service. The registry provided a reliable audit at twelve months post implementation. Deficits and limitations were identified and new strategies have been planned to overcome these problems and integrate the trauma registry into the process of clinical care. Copyright © 2013 Elsevier Ltd. All rights reserved.
Kaplan, Samuel; Chertock, Alan J.; Punches, James R.
1977-01-01
A method for spacing fast reactor fuel rods using a wire wrapper improved by orienting the wire-wrapped fuel rods in a unique manner which introduces desirable performance characteristics not attainable by previous wire-wrapped designs. Use of this method in a liquid metal fast breeder reactor results in: (a) improved mechanical performance, (b) improved rod-to-rod contact, (c) reduced steel volume, and (d) improved thermal-hydraulic performance. The method produces a "locked wrap" design which tends to lock the rods together at each of the wire cluster locations.
Campbell, J; Langdon, D; Cercignani, M; Rashid, W
2016-01-01
Aim. To explore the efficacy of home-based, computerised, cognitive rehabilitation in patients with multiple sclerosis using neuropsychological assessment and advanced structural and functional magnetic resonance imaging (fMRI). Methods. 38 patients with MS and cognitive impairment on the Brief International Cognitive Assessment for MS (BICAMS) were enrolled. Patients were randomised to undergo 45 minutes of computerised cognitive rehabilitation using RehaCom software ( n = 19) three times weekly for six weeks or to a control condition ( n = 19). Neuropsychological and MRI data were obtained at baseline (time 1), following the 6-week intervention (time 2), and after a further twelve weeks (time 3). Cortical activations were explored using fMRI and microstructural changes were explored using quantitative magnetisation transfer (QMT) imaging. Results. The treatment group showed a greater improvement in SDMT gain scores between baseline and time 2 compared to the control group ( p = 0.005). The treatment group exhibited increased activation in the bilateral prefrontal cortex and right temporoparietal regions relative to control group at time 3 ( p < 0.05 FWE corrected ). No significant changes were observed on QMT. Conclusion. This study supports the hypothesis that home-based, computerised, cognitive rehabilitation may be effective in improving cognitive performance in patients with MS. Clinical trials registration is ISRCTN54901925.
Designing healthcare information technology to catalyse change in clinical care.
Lester, William T; Zai, Adrian H; Grant, Richard W; Chueh, Henry C
2008-01-01
The gap between best practice and actual patient care continues to be a pervasive problem in our healthcare system. Efforts to improve on this knowledge-performance gap have included computerised disease management programs designed to improve guideline adherence. However, current computerised reminder and decision support interventions directed at changing physician behaviour have had only a limited and variable effect on clinical outcomes. Further, immediate pay-for-performance financial pressures on institutions have created an environment where disease management systems are often created under duress, appended to existing clinical systems and poorly integrated into the existing workflow, potentially limiting their real-world effectiveness. The authors present a review of disease management as well as a conceptual framework to guide the development of more effective health information technology (HIT) tools for translating clinical information into clinical action.
Pope, Catherine; Halford, Susan; Turnbull, Joanne; Prichard, Jane
2014-06-01
This article draws on data collected during a 2-year project examining the deployment of a computerised decision support system. This computerised decision support system was designed to be used by non-clinical staff for dealing with calls to emergency (999) and urgent care (out-of-hours) services. One of the promises of computerised decisions support technologies is that they can 'hold' vast amounts of sophisticated clinical knowledge and combine it with decision algorithms to enable standardised decision-making by non-clinical (clerical) staff. This article draws on our ethnographic study of this computerised decision support system in use, and we use our analysis to question the 'automated' vision of decision-making in healthcare call-handling. We show that embodied and experiential (human) expertise remains central and highly salient in this work, and we propose that the deployment of the computerised decision support system creates something new, that this conjunction of computer and human creates a cyborg practice.
Training and transfer effects of N-back training for brain-injured and healthy subjects.
Lindeløv, Jonas Kristoffer; Dall, Jonas Olsen; Kristensen, Casper Daniel; Aagesen, Marie Holt; Olsen, Stine Almgren; Snuggerud, Therese Ruud; Sikorska, Anna
2016-10-01
Working memory impairments are prevalent among patients with acquired brain injury (ABI). Computerised training targeting working memory has been researched extensively using samples from healthy populations but this field remains isolated from similar research in ABI patients. We report the results of an actively controlled randomised controlled trial in which 17 patients and 18 healthy subjects completed training on an N-back task. The healthy group had superior improvements on both training tasks (SMD = 6.1 and 3.3) whereas the ABI group improved much less (SMD = 0.5 and 1.1). Neither group demonstrated transfer to untrained tasks. We conclude that computerised training facilitates improvement of specific skills rather than high-level cognition in healthy and ABI subjects alike. The acquisition of these specific skills seems to be impaired by brain injury. The most effective use of computer-based cognitive training may be to make the task resemble the targeted behaviour(s) closely in order to exploit the stimulus-specificity of learning.
Aziz, Muhammad Tahir; Ur-Rehman, Tofeeq; Qureshi, Sadia; Bukhari, Nadeem Irfan
Medication errors in chemotherapy are frequent and lead to patient morbidity and mortality, as well as increased rates of re-admission and length of stay, and considerable extra costs. Objective: This study investigated the proposition that computerised chemotherapy ordering reduces the incidence and severity of chemotherapy protocol errors. A computerised physician order entry of chemotherapy order (C-CO) with clinical decision support system was developed in-house, including standardised chemotherapy protocol definitions, automation of pharmacy distribution, clinical checks, labeling and invoicing. A prospective study was then conducted in a C-CO versus paper based chemotherapy order (P-CO) in a 30-bed chemotherapy bay of a tertiary hospital. Both C-CO and P-CO orders, including pharmacoeconomic analysis and the severity of medication errors, were checked and validated by a clinical pharmacist. A group analysis and field trial were also conducted to assess clarity, feasibility and decision making. The C-CO was very usable in terms of its clarity and feasibility. The incidence of medication errors was significantly lower in the C-CO compared with the P-CO (10/3765 [0.26%] versus 134/5514 [2.4%]). There was also a reduction in dispensing time of chemotherapy protocols in the C-CO. The chemotherapy computerisation with clinical decision support system resulted in a significant decrease in the occurrence and severity of medication errors, improvements in chemotherapy dispensing and administration times, and reduction of chemotherapy cost.
Attitudes of nursing staff towards computerisation: a case of two hospitals in Nairobi, Kenya
2014-01-01
Background The health sector is faced with constant changes as new approaches to tackle illnesses are unveiled through research. Information, communication and technology have greatly transformed healthcare practice the world over. Nursing is continually exposed to a variety of changes. Variables including age, educational level, years worked in nursing, computer knowledge and experience have been found to influence the attitudes of nurses towards computerisation. The purpose of the study was to determine the attitudes of nurses towards the use of computers and the factors that influence these attitudes. Methods This cross sectional descriptive study was conducted among staff nurses working at one public hospital (Kenyatta National Hospital, (KNH) and one private hospital (Aga Khan University Hospital (AKUH). A convenience sample of 200 nurses filled the questionnaires. Data was collected using the modified Nurses’ Attitudes Towards Computerisation (NATC) questionnaire. Results Nurses had a favorable attitude towards computerisation. Non-users had a significantly higher attitude score compared to the users (p = 0.0274). Statistically significant associations were observed with age (p = 0.039), level of education (p = 0.025), duration of exposure to computers (p = 0.025) and attitudes towards computerisation. Conclusion Generally, nurses have positive attitudes towards computerisation. This information is important for the planning and implementation of computerisation in the hospital as suggested in other studies. PMID:24774008
Improved composite material and method for production of improved composite material
NASA Technical Reports Server (NTRS)
Farley, Gary L. (Inventor)
1994-01-01
A laminated composite material with improved interlaminar strength and damage tolerance having short rods distributed evenly throughout the composite material perpendicular to the laminae is introduced. Each rod is shorter than the thickness of the finished laminate, but several times as long as the thickness of each lamina. The laminate is made by inserting short rods in layers of prepreg material, and then stacking and curing prepreg material with rods inserted therethrough.
Harrison, Peter M C; Collins, Tom; Müllensiefen, Daniel
2017-06-15
Modern psychometric theory provides many useful tools for ability testing, such as item response theory, computerised adaptive testing, and automatic item generation. However, these techniques have yet to be integrated into mainstream psychological practice. This is unfortunate, because modern psychometric techniques can bring many benefits, including sophisticated reliability measures, improved construct validity, avoidance of exposure effects, and improved efficiency. In the present research we therefore use these techniques to develop a new test of a well-studied psychological capacity: melodic discrimination, the ability to detect differences between melodies. We calibrate and validate this test in a series of studies. Studies 1 and 2 respectively calibrate and validate an initial test version, while Studies 3 and 4 calibrate and validate an updated test version incorporating additional easy items. The results support the new test's viability, with evidence for strong reliability and construct validity. We discuss how these modern psychometric techniques may also be profitably applied to other areas of music psychology and psychological science in general.
Mechanisation and automation technologies development in work at construction sites
NASA Astrophysics Data System (ADS)
Sobotka, A.; Pacewicz, K.
2017-10-01
Implementing construction work that creates buildings is a very complicated and laborious task and requires the use of various types of machines and equipment. For years there has been a desire for designers and technologists to introduce devices that replace people’s work on machine construction, automation and even robots. Technologies for building construction are still being developed and implemented to limit people’s hard work and improve work efficiency and quality in innovative architectonical and construction solutions. New opportunities for improving work on the construction site include computerisation of technological processes and construction management for projects and processes. The aim of the paper was to analyse the development of mechanisation, automation and computerisation of construction processes and selected building technologies, with special attention paid to 3D printing technology. The state of mechanisation of construction works in Poland and trends in its development in construction technologies are presented. These studies were conducted on the basis of the available literature and a survey of Polish construction companies.
de Vries, Arjen E; van der Wal, Martje Hl; Bedijn, Wendy; de Jong, Richard M; van Dijk, Rene B; Hillege, Hans L; Jaarsma, Tiny
2012-12-01
In the last decades, the introduction of information and communication technology (ICT) in healthcare promised an improved quality of care while reducing workload and improving cost-effectiveness. This might be realised by the use of computer guided decision support systems and telemonitoring. This case study describes the process of care of a patient with chronic heart failure, who was treated with a computerised disease management system in combination with telemonitoring. With the help of these appliances, we think we were probably able to prevent at least two readmissions for heart failure in a period of 10 months. We also gained more insight into patient's behaviour with regards to compliance with the heart failure regimen at home. Frequent contact at distance and the online availability of physiological measurements at home facilitated patient tailored education and helped the patient to react adequately to symptoms of deterioration. Additionally, up-titration of heart failure medication was performed without contacting the patient at the outpatient clinic.
de Graaf, L Esther; Gerhards, Sylvia AH; Evers, Silvia MAA; Arntz, Arnoud; Riper, Heleen; Severens, Johan L; Widdershoven, Guy; Metsemakers, Job FM; Huibers, Marcus JH
2008-01-01
Background Major depression is a common mental health problem in the general population, associated with a substantial impact on quality of life and societal costs. However, many depressed patients in primary care do not receive the care they need. Reason for this is that pharmacotherapy is only effective in severely depressed patients and psychological treatments in primary care are scarce and costly. A more feasible treatment in primary care might be computerised cognitive behavioural therapy. This can be a self-help computer program based on the principles of cognitive behavioural therapy. Although previous studies suggest that computerised cognitive behavioural therapy is effective, more research is necessary. Therefore, the objective of the current study is to evaluate the (cost-) effectiveness of online computerised cognitive behavioural therapy for depression in primary care. Methods/Design In a randomised trial we will compare (a) computerised cognitive behavioural therapy with (b) treatment as usual by a GP, and (c) computerised cognitive behavioural therapy in combination with usual GP care. Three hundred mild to moderately depressed patients (aged 18–65) will be recruited in the general population by means of a large-scale Internet-based screening (N = 200,000). Patients will be randomly allocated to one of the three treatment groups. Primary outcome measure of the clinical evaluation is the severity of depression. Other outcomes include psychological distress, social functioning, and dysfunctional beliefs. The economic evaluation will be performed from a societal perspective, in which all costs will be related to clinical effectiveness and health-related quality of life. All outcome assessments will take place on the Internet at baseline, two, three, six, nine, and twelve months. Costs are measured on a monthly basis. A time horizon of one year will be used without long-term extrapolation of either costs or quality of life. Discussion Although computerised cognitive behavioural therapy is a promising treatment for depression in primary care, more research is needed. The effectiveness of online computerised cognitive behavioural therapy without support remains to be evaluated as well as the effects of computerised cognitive behavioural therapy in combination with usual GP care. Economic evaluation is also needed. Methodological strengths and weaknesses are discussed. Trial registration The study has been registered at the Netherlands Trial Register, part of the Dutch Cochrane Centre (ISRCTN47481236). PMID:18590518
Mancardi, G L; Uccelli, M M; Sonnati, M; Comi, G; Milanese, C; De Vincentiis, A; Battaglia, M A
2000-04-01
The SMile Card was developed as a means for computerising clinical information for the purpose of transferability, accessibility, standardisation and compilation of a national database of demographic and clinical information about multiple sclerosis (MS) patients. In many European countries, centres for MS are organised independently from one another making collaboration, consultation and patient referral complicated. Only the more highly advanced clinical centres, generally located in large urban areas, have had the possibility to utilise technical possibilities for improving the organisation of patient clinical and research information, although independently from other centres. The information system, developed utilising the Visual Basic language for Microsoft Windows 95, stores information via a 'smart card' in a database which is initiated and updated utilising a microprocessor, located at each neurological clinic. The SMile Card, currently being tested in Italy, permits patients to carry with them all relevant medical information without limitations. Neurologists are able to access and update, via the microprocessor, the patient's entire medical history and MS-related information, including the complete neurological examination and laboratory test results. The SMile Card provides MS patients and neurologists with a complete computerised archive of clinical information which is accessible throughout the country. In addition, data from the SMile Card system can be exported to other database programs.
Hogg, K; Dawson, D; Mackway‐Jones, K
2006-01-01
Objectives To measure the diagnostic accuracy of computerised strain gauge plethysmography in the diagnosis of pulmonary embolism (PE). Methods Two researchers prospectively recruited 425 patients with pleuritic chest pain presenting to the emergency department (ED). Lower limb computerised strain gauge plethysmography was performed in the ED. All patients underwent an independent reference standard diagnostic algorithm to establish the presence or absence of PE. A low modified Wells' clinical probability combined with a normal D‐dimer excluded PE. All others required diagnostic imaging with PIOPED interpreted ventilation perfusion scanning and/or computerised tomography (CT) pulmonary angiography. Patients with a nondiagnostic CT had digital subtraction pulmonary angiography. All patients were followed up clinically for 3 months. Results The sensitivity of computerised strain gauge plethysmography was 33.3% (95% confidence interval (CI) 16.3 to 56.2%) and specificity 64.1% (95% CI 59.0 to 68.8%). The negative likelihood ratio was 1.04 (95% CI 0.68 to 1.33) and positive likelihood ratio 0.93 (95% CI 0.45 to 1.60). Conclusions Lower limb computerised strain gauge plethysmography does not aid in the diagnosis of PE. PMID:16439734
Triñanes, Yolanda; Atienza, Gerardo; Louro-González, Arturo; de-las-Heras-Liñero, Elena; Alvarez-Ariza, María; Palao, Diego J
2015-01-01
One of the proposals for improving clinical practice is to introduce computerised decision support systems (CDSS) and integrate these with electronic medical records. Accordingly, this study sought to systematically review evidence on the effectiveness of CDSS in the management of depression. A search was performed in Medline, EMBASE and PsycInfo, in order to do this. The quality of quantitative studies was assessed using the SIGN method, and qualitative studies using the CASPe checklist. Seven studies were identified (3 randomised clinical trials, 3 non-randomised trials, and one qualitative study). The CDSS assessed incorporated content drawn from guidelines and other evidence-based products. In general, the CDSS had a positive impact on different aspects, such as the screening and diagnosis, treatment, improvement in depressive symptoms and quality of life, and referral of patients. The use of CDSS could thus serve to optimise care of depression in various scenarios by providing recommendations based on the best evidence available and facilitating decision-making in clinical practice. Copyright © 2014 SEP y SEPB. Published by Elsevier España. All rights reserved.
Pathologists dislike sound? Evaluation of a computerised training microscope.
Gray, E; Duvall, E; Sprey, J; Bird, C C
1998-01-01
AIM: To evaluate the use of multimedia enhancements, using a computerised microscope, in the training of microscope skills. METHODS: The HOME microscope provides facilities to highlight features of interest in conjunction with either text display or aural presentation. A pilot study was carried out with 10 individuals, eight of whom were at different stages of pathology training. A tutorial was implemented employing sound or text, and each individual tested each version. Both the subjective impressions of users and objective measurement of their patterns of use were recorded. RESULTS: Although both versions improved learning, users took longer to work through the aural than the text version; 90% of users preferred the text only version, including all eight individuals involved in pathology training. CONCLUSIONS: Pathologists appear to prefer visual rather than aural input when using teaching systems such as the HOME microscope and sound does not give added value to the training experience. Images PMID:9659250
Maclean, Donald; Younes, Hakim Ben; Forrest, Margaret; Towers, Hazel K
2012-03-01
Accurate and timely clinical data are required for clinical and organisational purposes and is especially important for patient management, audit of surgical performance and the electronic health record. The recent introduction of computerised theatre management systems has enabled real-time (point-of-care) operative procedure coding by clinical staff. However the accuracy of these data is unknown. The aim of this Scottish study was to compare the accuracy of theatre nurses' real-time coding on the local theatre management system with the central Scottish Morbidity Record (SMR01). Paired procedural codes were recorded, qualitatively graded for precision and compared (n = 1038). In this study, real-time, point-of-care coding by theatre nurses resulted in significant coding errors compared with the central SMR01 database. Improved collaboration between full-time coders and clinical staff using computerised decision support systems is suggested.
Use of Ionic Liquids in Rod-Coil Block Copolyimides for Improved Lithium Ion Conduction
NASA Technical Reports Server (NTRS)
Meador, Mary Ann B.; Tigelaar, Dean M.; Chapin, Kara; Bennett, William R.
2007-01-01
Solvent-free, solid polymer electrolytes (SPE) have the potential to improve safety, increase design flexibility and enhance performance of rechargeable lithium batteries. Solution based electrolytes are flammable and typically incompatible with lithium metal anodes, limiting energy density. We have previously demonstrated use of polyimide rod coil block copolymers doped with lithium salts as electrolytes for lithium polymer batteries. The polyimide rod blocks provide dimensional stability while the polyethylene oxide (PEO) coil portions conduct ions. Phase separation of the rods and coils in these highly branched polymers provide channels with an order of magnitude improvement in lithium conduction over polyethylene oxide itself at room temperature. In addition, the polymers have been demonstrated in coin cells to be compatible with lithium metal. For practical use at room temperature and below, however, at least an order of magnitude improvement in ion conduction is still required. The addition of nonvolatile, room temperature ionic liquids has been shown to improve the ionic conductivity of high molecular weight PEO. Herein we describe use of these molten salts to improve ionic conductivity in the rod-coil block copolymers.
CPOE in Iran--a viable prospect? Physicians' opinions on using CPOE in an Iranian teaching hospital.
Kazemi, Alireza; Ellenius, Johan; Tofighi, Shahram; Salehi, Aref; Eghbalian, Fatemeh; Fors, Uno G
2009-03-01
In recent years, the theory that on-line clinical decision support systems can improve patients' safety among hospitalised individuals has gained greater acceptance. However, the feasibility of implementing such a system in a middle or low-income country has rarely been studied. Understanding the current prescription process and a proper needs assessment of prescribers can act as the key to successful implementation. The aim of this study was to explore physicians' opinions on the current prescription process, and the expected benefits and perceived obstacles to employ Computerised Physician Order Entry in an Iranian teaching hospital. Initially, the interview guideline was developed through focus group discussions with eight experts. Then semi-structured interviews were held with 19 prescribers. After verbatim transcription, inductive thematic analysis was performed on empirical data. Forty hours of on-looker observations were performed in different wards to explore the current prescription process. The current prescription process was identified as a physician-centred, top-down, model, where prescribers were found to mostly rely on their memories as well as being overconfident. Some errors may occur during different paper-based registrations, transcriptions and transfers. Physician opinions on Computerised Physician Order Entry were categorised into expected benefits and perceived obstacles. Confidentiality issues, reduction of medication errors and educational benefits were identified as three themes in the expected benefits category. High cost, social and cultural barriers, data entry time and problems with technical support emerged as four themes in the perceived obstacles category. The current prescription process has a high possibility of medication errors. Although there are different barriers confronting the implementation and continuation of Computerised Physician Order Entry in Iranian hospitals, physicians have a willingness to use them if these systems provide significant benefits. A pilot study in a limited setting and a comprehensive analysis of health outcomes and economic indicators should be performed, to assess the merits of introducing Computerised Physician Order Entry with decision support capabilities in Iran.
Applying Adaptive Variables in Computerised Adaptive Testing
ERIC Educational Resources Information Center
Triantafillou, Evangelos; Georgiadou, Elissavet; Economides, Anastasios A.
2007-01-01
Current research in computerised adaptive testing (CAT) focuses on applications, in small and large scale, that address self assessment, training, employment, teacher professional development for schools, industry, military, assessment of non-cognitive skills, etc. Dynamic item generation tools and automated scoring of complex, constructed…
ERIC Educational Resources Information Center
Kirk, Hannah E.; Gray, Kylie M.; Ellis, Kirsten; Taffe, John; Cornish, Kim M.
2016-01-01
Background: Children with intellectual and developmental disabilities (IDD) experience heightened attention difficulties which have been linked to poorer cognitive, academic and social outcomes. Although, increasing research has focused on the potential of computerised cognitive training in reducing attention problems, limited studies have…
Do Computers Improve the Drawing of a Geometrical Figure for 10 Year-Old Children?
ERIC Educational Resources Information Center
Martin, Perrine; Velay, Jean-Luc
2012-01-01
Nowadays, computer aided design (CAD) is widely used by designers. Would children learn to draw more easily and more efficiently if they were taught with computerised tools? To answer this question, we made an experiment designed to compare two methods for children to do the same drawing: the classical "pen and paper" method and a CAD…
Ellison, GTH; Richter, LM; de Wet, T; Harris, HE; Griesel, RD; McIntyre, JA
2007-01-01
This study examined the reliability of hand-written and computerised records of birth data collected during the Birth to Ten study at Baragwanath Hospital in Soweto. The reliability of record-keeping in hand-written obstetric and neonatal files was assessed by comparing duplicate records of six different variables abstracted from six different sections in these files. The reliability of computerised record-keeping was assessed by comparing the original hand-written record of each variable with records contained in the hospital’s computerised database. These data sets displayed similar levels of reliability which suggests that similar errors occurred when data were transcribed from one section of the files to the next, and from these files to the computerised database. In both sets of records reliability was highest for the categorical variable infant sex, and for those continuous variables (such as maternal age and gravidity) recorded with unambiguous units. Reliability was lower for continuous variables that could be recorded with different levels of precision (such as birth weight), those that were occasionally measured more than once, and those that could be measured using more than one measurement technique (such as gestational age). Reducing the number of times records are transcribed, categorising continuous variables, and standardising the techniques used for measuring and recording variables would improve the reliability of both hand-written and computerised data sets. OPSOMMING In hierdie studie is die betroubaarheid van handgeskrewe en gerekenariseerde rekords van ge boortedata ondersoek, wat versamel is gedurende die ‘Birth to Ten’ -studie aan die Baragwanath hospitaal in Soweto. Die betroubaarheid van handgeskrewe verloskundige en pasgeboortelike rekords is beoordeel deur duplikaatrekords op ses verskillende verander likes te vergelyk, wat onttrek is uit ses verskillende dele van die betrokke lêers. Die gerekenariseerde rekords se betroubaarheid is beoordeel deur die oorspronklike geskrewe rekord van elke veranderlike te vergelyk met rekords wat beskikbaar is in die hospitaal se gerekenariseerde databasis Hierdie datastelle her vergelykbare vlakke van betroubaarheid getoon, waaruit afgelei kan word dat soortgelyke foute voorkom warmeer data oorgeplaas word vaneen deeivan ’n lêer na ’n ander, en vanaf die lêer na die gerekenariseerde databasis. In albei stelle rekords was die betroubaarheid die hoogste vir die kategoriese veranderlike suigeling se geslag, en vir daardie kontinue veranderlikes (soos moeder se ouderdom en gravida) wat in terme van ondubbelsinmge eenhede gekodeer kan word. Kontinue veranderlikes wat op wisselende vlakke van akkuratheid gemeet word (soos gewig met geboorte), veranderlikes wat soms meer as een keer gemeet is, en veranderlikes wat voigens meer as een metingstegniek bepaal is (soos draagtydsouderdom), was minder betroubaar Deur die aantal kere wat rekords oorgeskryf moet word te verminder, kontinue veranderlikes tat kategoriese veranderlikes te wysig. en tegnieke vir meting en aantekening van veranderlikes te standardiseer, kan die betroubaarheid van sowel handgeskrewe as gerekenariseerde datastelle verbeter word. PMID:9287552
NASA Astrophysics Data System (ADS)
Zhu, Yuan; Eschrich, Tina; Leich, Martin; Grimm, Stephan; Kobelke, Jens; Lorenz, Martin; Bartelt, Hartmut; Jäger, Matthias
2017-10-01
The use of short local tapers in large mode area fiber amplifiers is proposed for peak power scaling while maintaining good beam quality. To avoid modal distortions, the powder-sintering (REPUSIL) method was employed to obtain core materials with excellent refractive index homogeneity. First experiments with Yb3+-doped rod-type amplifiers delivered 2 ns pulses with peak powers of 540 kW and energies of 1.4 mJ for the untapered rod and 230 kW for the tapered rod (limited by facet damage). The beam quality improved from an M 2 value of approximately 10 to 3.5. The investigation of the taper structure indicates room for further improvement.
Demography, Social Structure and Learning through Life
ERIC Educational Resources Information Center
van der Veen, Ruud
2010-01-01
The modernisation of the Western world during the last two centuries has been a mix of industrialisation/computerisation and urbanisation. Consequently, reports on the future of adult learning and adult education have been a mix on the one hand of the learning requirements that follow from industrialisation/computerisation and on the other hand,…
Computerised Accounting Software; A Curriculum That Enhances an Accounting Programme
ERIC Educational Resources Information Center
Machera, Robert P.; Machera, Precious C.
2017-01-01
There has been an outcry in commerce and industry about students who fail to perform in the accounting department due to lack of "practical accounting skills". It is from this background that the researchers were motivated to investigate the impact of a Computerised Accounting Software Curriculum that enhances an Accounting Programme. At…
Pennant, Mary E; Loucas, Christina E; Whittington, Craig; Creswell, Cathy; Fonagy, Peter; Fuggle, Peter; Kelvin, Raphael; Naqvi, Sabrina; Stockton, Sarah; Kendall, Tim
2015-04-01
One quarter of children and young people (CYP) experience anxiety and/or depression before adulthood, but treatment is sometimes unavailable or inadequate. Self-help interventions may have a role in augmenting treatment and this work aimed to systematically review the evidence for computerised anxiety and depression interventions in CYP aged 5-25 years old. Databases were searched for randomised controlled trials and 27 studies were identified. For young people (12-25 years) with risk of diagnosed anxiety disorders or depression, computerised CBT (cCBT) had positive effects for symptoms of anxiety (SMD -0.77, 95% CI -1.45 to -0.09, k = 6, N = 220) and depression (SMD -0.62, 95% CI -1.13 to -0.11, k = 7, N = 279). In a general population study of young people, there were small positive effects for anxiety (SMD -0.15, 95% CI -0.26 to -0.03; N = 1273) and depression (SMD -0.15, 95% CI -0.26 to -0.03; N = 1280). There was uncertainty around the effectiveness of cCBT in children (5-11 years). Evidence for other computerised interventions was sparse and inconclusive. Computerised CBT has potential for treating and preventing anxiety and depression in clinical and general populations of young people. Further program development and research is required to extend its use and establish its benefit in children. Copyright © 2015 Elsevier Ltd. All rights reserved.
Davis, N F; Murray, G; O'Connor, T; Browne, C; MacCraith, E; Galvin, D; Mulvin, D; Quinlan, D; Lennon, G
2017-11-01
A forgotten ureteric stent may result in severe renal impairment leading to nephrectomy. To compare the effectiveness of a centralised computerised registry for monitoring ureteric stent activity with a previously established theatre stent logbook system. This prospective audit was performed in two 9-monthly intervals. During the first interval, insertion/removal of a ureteric stent was documented in a specific theatre stent logbook. In the second interval, an electronic centralised computerised registry was developed to document insertion/removal of a ureteric stent onto an accessible hospital server. A computerised traffic-light system was also developed to identify patients with an indwelling stent for >3 months. The primary outcome variable was the number of prolonged indwelling ureteric stents in both groups. During the first time interval, 188 ureteric stents were inserted and 182 (96%) were removed or changed. Six (4%) patients underwent insertion of a ureteric stent for a prolonged period of time (>6 months). This subgroup required complex endourological intervention for stent removal due to encrustation. During the second time interval, 157 ureteric stents were inserted and all patients had their stent removed or changed within 6 months. No patients in this group were lost to follow-up. This study demonstrates that a centralised computerised ureteric stent registry is superior to a conventional logbook for monitoring ureteric stent activity. We propose the introduction a centralised nationalised ureteric stent registry for eliminating the potential for prolonged or forgotten ureteric stents.
Evaluation of three indices for biofilm accumulation on complete dentures.
Paranhos, Helena de Freitas Oliveira; Lovato da Silva, Claudia Helena; de Souza, Raphael Freitas; Pontes, Karina Matthes de Freitas
2010-03-01
The objective of this study was to evaluate the accuracy and reproducibility of three complete denture biofilm indices (Prosthesis Hygiene Index; Jeganathan et al. Index; Budtz-Jørgensen Index) by means of a computerised comparison method. Clinical studies into denture hygiene have employed a large number of biofilm indices among their outcome variables. However, the knowledge about the validity of these indices is still scarce. Sixty-two complete denture wearers were selected. The internal surfaces of the upper complete dentures were stained (5% erythrosine) and photographed. The slides were projected on paper, and the biofilm indices were applied over the photos by means of a scoring method. For the computerised method, the areas (total and biofilm-covered) were measured by dedicated software (Image Tool). In addition, to compare the results of the computerised method and Prosthetic Hygiene Index, a new scoring scale (including four and five graded) was introduced. For the Jeganathan et al. and Budtz-Jørgensen indices, the original scales were used. Values for each index were compared with the computerised method by the Friedman test. Their reproducibility was measured by means of weighed kappa. Significance for both tests was set at 0.05. The indices tested provided similar mean measures but they tended to overestimate biofilm coverage when compared with the computerised method (p < 0.001). Agreement between the Prosthesis Hygiene Index and the computerised method was not significant, regardless of the scale used. Jeghanathan et al. Index showed weak agreement, and consistent results were found for Budtz-Jorgensen Index (kappa = 0.19 and 0.39 respectively). Assessment of accuracy for the biofilm indices showed instrument bias that was similar among the tested methods. Weak inter-instrument reproducibility was found for the indices, except for the Budtz-Jørgensen Index. This should be the method of choice for clinical studies when more sophisticated approaches are not possible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reese, A.P.; Crowther, R.L. Jr.
1992-02-18
This patent describes improvement in a boiling water reactor core having a plurality of vertically upstanding fuel bundles; each fuel bundle containing longitudinally extending sealed rods with fissile material therein; the improvement comprises the fissile material including a mixture of uranium and recovered plutonium in rods of the fuel bundle at locations other than the corners of the fuel bundle; and, neutron absorbing material being located in rods of the fuel bundle at rod locations adjacent the corners of the fuel bundles whereby the neutron absorbing material has decreased shielding from the plutonium and maximum exposure to thermal neutrons formore » shaping the cold reactivity shutdown zone in the fuel bundle.« less
Spacer grid assembly and locking mechanism
Snyder, Jr., Harold J.; Veca, Anthony R.; Donck, Harry A.
1982-01-01
A spacer grid assembly is disclosed for retaining a plurality of fuel rods in substantially parallel spaced relation, the spacer grids being formed with rhombic openings defining contact means for engaging from one to four fuel rods arranged in each opening, the spacer grids being of symmetric configuration with their rhombic openings being asymmetrically offset to permit inversion and relative rotation of the similar spacer grids for improved support of the fuel rods. An improved locking mechanism includes tie bars having chordal surfaces to facilitate their installation in slotted circular openings of the spacer grids, the tie rods being rotatable into locking engagement with the slotted openings.
Evolution of a residue laboratory network and the management tools for monitoring its performance.
Lins, E S; Conceição, E S; Mauricio, A De Q
2012-01-01
Since 2005 the National Residue & Contaminants Control Plan (NRCCP) in Brazil has been considerably enhanced, increasing the number of samples, substances and species monitored, and also the analytical detection capability. The Brazilian laboratory network was forced to improve its quality standards in order to comply with the NRCP's own evolution. Many aspects such as the limits of quantification (LOQs), the quality management systems within the laboratories and appropriate method validation are in continuous improvement, generating new scenarios and demands. Thus, efficient management mechanisms for monitoring network performance and its adherence to the established goals and guidelines are required. Performance indicators associated to computerised information systems arise as a powerful tool to monitor the laboratories' activity, making use of different parameters to describe this activity on a day-to-day basis. One of these parameters is related to turnaround times, and this factor is highly affected by the way each laboratory organises its management system, as well as the regulatory requirements. In this paper a global view is presented of the turnaround times related to the type of analysis, laboratory, number of samples per year, type of matrix, country region and period of the year, all these data being collected from a computerised system called SISRES. This information gives a solid background to management measures aiming at the improvement of the service offered by the laboratory network.
ERIC Educational Resources Information Center
Van der Molen, M. J.; Van Luit, J. E. H.; Van der Molen, M. W.; Klugkist, I.; Jongmans, M. J.
2010-01-01
Background: The goal of this study is to evaluate the effectiveness of a computerised working memory (WM) training on memory, response inhibition, fluid intelligence, scholastic abilities and the recall of stories in adolescents with mild to borderline intellectual disabilities attending special education. Method: A total of 95 adolescents with…
ERIC Educational Resources Information Center
Toyoda, Etsuko
2016-01-01
For second-language learners to effectively and efficiently gather information from online texts in their target language, a well-designed computerised system to assist their reading is essential. While many articles and websites which introduce electronic second-language learning tools exist, evaluation of their functions in relation to the…
ERIC Educational Resources Information Center
Wei, Wei; Zheng, Ying
2017-01-01
This research provided a comprehensive evaluation and validation of the listening section of a newly introduced computerised test, Pearson Test of English Academic (PTE Academic). PTE Academic contains 11 item types assessing academic listening skills either alone or in combination with other skills. First, task analysis helped identify skills…
Using a Computerised Graphics Package to Achieve a Technology-Oriented Classroom
ERIC Educational Resources Information Center
Aladejana, Francisca; Idowu, Lanre
2009-01-01
The present situation in Nigeria involves students of fine arts, a practical-oriented subject, being exposed to poor methods of teaching with consequent poor performances. This study examined the extent to which the use of a computerised graphics package could make the classroom technology-oriented and affect the performance of learners. This is…
A New Computerised Advanced Theory of Mind Measure for Children with Asperger Syndrome: The ATOMIC
ERIC Educational Resources Information Center
Beaumont, Renae B.; Sofronoff, Kate
2008-01-01
This study examined the ability of children with Asperger Syndrome (AS) to attribute mental states to characters in a new computerised, advanced theory of mind measure: The Animated Theory of Mind Inventory for Children (ATOMIC). Results showed that children with AS matched on IQ, verbal comprehension, age and gender performed equivalently on…
ERIC Educational Resources Information Center
Ghilay, Yaron; Ghilay, Ruth
2012-01-01
The study examined advantages and disadvantages of computerised assessment compared to traditional evaluation. It was based on two samples of college students (n=54) being examined in computerised tests instead of paper-based exams. Students were asked to answer a questionnaire focused on test effectiveness, experience, flexibility and integrity.…
Lee, Kang Yeol; Hwang, Hayoung; Kim, Tae Ho; Choi, Wonjoon
2016-02-10
The development of an efficient method for manipulating phase and surface transformations would facilitate the improvement of catalytic materials for use in a diverse range of applications. Herein, we present the first instance of a submicrosecond time frame direct phase and surface transformation of Bi(NO3)3 rods to nanoporous β-Bi2O3 rods via structure-guided combustion waves. Hybrid composites of the prepared Bi(NO3)3·H2O rods and organic fuel were fabricated by a facile preparation method. The anisotropic propagation of combustion waves along the interfacial boundaries of Bi(NO3)3·H2O rods induced direct phase transformation to β-Bi2O3 rods in the original structure due to the rapid pyrolysis, while the release of gas molecules enabled the formation of nanoporous structures on the surfaces of rods. The developed β-Bi2O3 rods showed improved photocatalytic activity for the photodegradation of rhodamine B in comparison with Bi(NO3)3·H2O rods and α-Bi2O3 rods due to the more suitable interdistance and the large contact areas of the porous surfaces. This new method of using structure-guided combustion waves for phase and surface transformation may contribute to the development of new catalysts as well as the precise manipulation of diverse micronanostructured materials.
Tensiometer with removable wick
Gee, Glendon W.; Campbell, Melvin D.
1992-01-01
The present invention relates to improvements in tensiometers for measuring soil water tension comprising a rod shaped wick. the rod shaped wick is shoestring, rolled paper towel, rolled glass microfiber filter, or solid ceramic. The rod shaped wick is secured to the tensiometer by a cone washer and a threaded fitting.
Newby, Jill M; Twomey, Conal; Yuan Li, Susan Shi; Andrews, Gavin
2016-07-15
An increasing number of computerised transdiagnostic cognitive behavioural therapy programs (TD-cCBT) have been developed in the past decade, but there are no meta-analyses to explore the efficacy of these programs, nor moderators of the effects. The current meta-analysis focused on studies evaluating TD-cCBT interventions to examine their effects on anxiety, depression and quality of life (QOL). Results from 17 RCTs showed computerised TD-cCBT outperformed control conditions on all outcome measures at post-treatment, with large effect sizes for depression (g's=.84), and medium effect sizes for anxiety (g=.78) and QOL (g=.48). RCT quality was generally good, although heterogeneity was moderate to high. Further analyses revealed that studies comparing TD-cCBT to waitlist controls had the largest differences (g=.93) compared to active (g=.59) and usual care control groups (g=.37) on anxiety outcomes, but there was no influence of control group subtype on depression outcomes. Treatment length, symptom target (mixed versus anxiety only), treatment design (standardised versus tailored), and therapist experience (students versus qualified therapists) did not influence the results. Preliminary evidence from 4 comparisons with disorder-specific treatments suggests transdiagnostic treatments are as effective for reducing anxiety, and there may be small but superior outcomes for TD-cCBT programs for reducing depression (g=.21) and improving QOL (g=.21) compared to disorder-specific cCBT. These findings show that TD-cCBT programs are efficacious, and have comparable effects to disorder-specific cCBT programs. Copyright © 2016 Elsevier B.V. All rights reserved.
Future of computerised electrocardiography.
Meijler, F L; Robles de Medina, E O; Helder, J C
1980-01-01
The advent of computerised electrocardiography has been of prime importance for the storage and retrieval of data, but none of the available systems is of universal application for analysis of patterns. Future needs require hierarchical systems of increasing degrees of complexity, depending on the source of requests, and there should be appropriate provision for review by cardiologists before the final report is issued. PMID:7000098
Review and Reward within the Computerised Peer-Assessment of Essays
ERIC Educational Resources Information Center
Davies, Phil
2009-01-01
This article details the implementation and use of a "Review Stage" within the CAP (computerised assessment by peers) tool as part of the assessment process for a post-graduate module in e-learning. It reports upon the effect of providing the students with a "second chance" in marking and commenting their peers' essays having been able to view the…
Two-phase pressure drop reduction BWR assembly design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dix, G.E.; Crowther, R.L.; Colby, M.J.
1991-05-21
This patent describes an improved fuel assembly for a boiling water reactor. It comprises: a fuel channel; a lower tie plate; an upper tie plate; the lower tie plate and the upper tie plate defining a two-dimensional matrix; at least one water rod the fuel rods being partial length rods.
Tensiometer with removable wick
Gee, G.W.; Campbell, M.D.
1992-04-14
The present invention relates to improvements in tensiometers for measuring soil water tension comprising a rod shaped wick. The rod shaped wick is a shoestring, rolled paper towel, rolled glass microfiber filter, or solid ceramic. The rod shaped wick is secured to the tensiometer by a cone washer and a threaded fitting. 2 figs.
A feasibility study of a new computerised cognitive remediation for young adults with schizophrenia
Cellard, Caroline; Reeder, Clare; Paradis-Giroux, Andrée-Anne; Roy, Marc-André; Gilbert, Elsa; Ivers, Hans; Bouchard, Roch-Hugo; Maziade, Michel; Wykes, Til
2016-01-01
Cognitive remediation therapy is effective for improving cognition, symptoms and social functioning in individuals with schizophrenia; however, the impact on visual episodic memory remains unclear. The objectives of this feasibility study were: (1) to explore whether or not CIRCuiTS—a new computerised cognitive remediation therapy programme developed in England—improves visual episodic memory and other cognitive domains in young adults with early course schizophrenia; and (2) to evaluate acceptability of the CIRCuiTS programme in French-Canadians. Three participants with visual episodic memory impairments at baseline were recruited from clinical settings in Canada, and consented to participate. Neuropsychological, clinical and social functioning was evaluated at baseline and post-treatment. Intervention involved 40 sessions of cognitive remediation. First, the reliable change index (RCI) revealed that each participant demonstrated significant post-therapy change in episodic memory and in other cognitive domains. The response profile was characterised by the use of organisational strategies. Second, the treatment was considered acceptable to participants in terms of session frequency (number of sessions per week), intensity (hours per week; total hours), and number of missed sessions and total completed sessions. This preliminary study yielded encouraging data demonstrating the feasibility of the CIRCuiTS programme in French-Canadian young adults with schizophrenia. PMID:25753694
NASA Astrophysics Data System (ADS)
Agus, M.; Mascia, M. L.; Fastame, M. C.; Melis, V.; Pilloni, M. C.; Penna, M. P.
2015-02-01
A body of literature shows the significant role of visual-spatial skills played in the improvement of mathematical skills in the primary school. The main goal of the current study was to investigate the impact of a combined visuo-spatial and mathematical training on the improvement of mathematical skills in 146 second graders of several schools located in Italy. Participants were presented single pencil-and-paper visuo-spatial or mathematical trainings, computerised version of the above mentioned treatments, as well as a combined version of computer-assisted and pencil-and-paper visuo-spatial and mathematical trainings, respectively. Experimental groups were presented with training for 3 months, once a week. All children were treated collectively both in computer-assisted or pencil-and-paper modalities. At pre and post-test all our participants were presented with a battery of objective tests assessing numerical and visuo-spatial abilities. Our results suggest the positive effect of different types of training for the empowerment of visuo-spatial and numerical abilities. Specifically, the combination of computerised and pencil-and-paper versions of visuo-spatial and mathematical trainings are more effective than the single execution of the software or of the pencil-and-paper treatment.
Nambiar, Mithun; Yang, Yi; Liew, Susan; Turner, Peter L; Torode, Ian P
2016-10-01
Single or dual-rod instrumentation can be used for the anterior fixation of the spine in adolescent idiopathic scoliosis (AIS). We aim to compare the complications, radiographic and functional outcomes of patients with AIS who have undergone single and dual-rod instrumentation. This is a multi-centre study involving the Royal Children's, Royal Melbourne and Epworth hospitals. Three primary surgeons were involved to ensure homogeneity of surgical technique and implants. Patients with AIS and thoracolumbar curves (Lenke 5 and 6) undergoing anterior instrumentation from 1st January 2000 to 30th June 2013 were included. Radiographic data were collected from X-rays. The functional outcome was measured through the Scoliosis Research Society questionnaire (SRS-30). The study included 58 patients (38 single-rod and 20 dual-rod patients). Thirty-nine patients were classified with Lenke 5 curves, while 19 patients had Lenke 6 curves. Structural interbody supports were used in 95 % of cases. In the preoperative to postoperative period, patients with single rods had an improvement of 75 and 51 % for primary and secondary curves, respectively, while patients with dual rods had an improvement of 70 and 38 % for primary and secondary curves, respectively. There were no cases of pseudoarthrosis or metalware failure in either group. Two patients (one single-rod and one dual-rod patient) required further unplanned posterior fusion. 91 % of patients were satisfied with the results of their back management. Pseudoarthrosis and metalware failure are rare complications of anterior instrumentation. Our study found no significant difference in functional or radiographic outcome between single and dual-rod instrumentation. Level III.
Rod Electroretinograms Elicited by Silent Substitution Stimuli from the Light-Adapted Human Eye
Maguire, John; Parry, Neil R. A.; Kremers, Jan; Kommanapalli, Deepika; Murray, Ian J.; McKeefry, Declan J.
2016-01-01
Purpose To demonstrate that silent substitution stimuli can be used to generate electroretinograms (ERGs) that effectively isolate rod photoreceptor function in humans without the need for dark adaptation, and that this approach constitutes a viable alternative to current clinical standard testing protocols. Methods Rod-isolating and non-isolating sinusoidal flicker stimuli were generated on a 4 primary light-emitting diode (LED) Ganzfeld stimulator to elicit ERGs from participants with normal and compromised rod function who had not undergone dark-adaptation. Responses were subjected to Fourier analysis, and the amplitude and phase of the fundamental were used to examine temporal frequency and retinal illuminance response characteristics. Results Electroretinograms elicited by rod-isolating silent substitution stimuli exhibit low-pass temporal frequency response characteristics with an upper response limit of 30 Hz. Responses are optimal between 5 and 8 Hz and between 10 and 100 photopic trolands (Td). There is a significant correlation between the response amplitudes obtained with the silent substitution method and current standard clinical protocols. Analysis of signal-to-noise ratios reveals significant differences between subjects with normal and compromised rod function. Conclusions Silent substitution provides an effective method for the isolation of human rod photoreceptor function in subjects with normal as well as compromised rod function when stimuli are used within appropriate parameter ranges. Translational Relevance This method of generating rod-mediated ERGs can be achieved without time-consuming periods of dark adaptation, provides improved isolation of rod- from cone-based activity, and will lead to the development of faster clinical electrophysiologic testing protocols with improved selectivity. PMID:27617180
Low-cost Engineering of Laser Rods and Slabs with Liquid Phase Epitaxy
2011-09-01
SUPPLEMENTARY NOTES 14. ABSTRACT We investigated the use of a liquid phase epitaxial ( LPE ) coating to improve the performance of a rod or slab laser. A...single crystal erbium-doped yttrium aluminum garnet (Er:YAG) rod coated with undoped YAG, and an uncoated sample were procured, then compared on the...the whispering gallery modes, which otherwise would deplete the gain in ~50% of the rod volume. We also investigated LPE growth on a ceramic sample
Gilman, Robert H; Tielsch, James M; Steinhoff, Mark; Figueroa, Dante; Rodriguez, Shalim; Caffo, Brian; Tracey, Brian; Elhilali, Mounya; West, James; Checkley, William
2012-01-01
Introduction WHO case management algorithm for paediatric pneumonia relies solely on symptoms of shortness of breath or cough and tachypnoea for treatment and has poor diagnostic specificity, tends to increase antibiotic resistance. Alternatives, including oxygen saturation measurement, chest ultrasound and chest auscultation, exist but with potential disadvantages. Electronic auscultation has potential for improved detection of paediatric pneumonia but has yet to be standardised. The authors aim to investigate the use of electronic auscultation to improve the specificity of the current WHO algorithm in developing countries. Methods This study is designed to test the hypothesis that pulmonary pathology can be differentiated from normal using computerised lung sound analysis (CLSA). The authors will record lung sounds from 600 children aged ≤5 years, 100 each with consolidative pneumonia, diffuse interstitial pneumonia, asthma, bronchiolitis, upper respiratory infections and normal lungs at a children's hospital in Lima, Peru. The authors will compare CLSA with the WHO algorithm and other detection approaches, including physical exam findings, chest ultrasound and microbiologic testing to construct an improved algorithm for pneumonia diagnosis. Discussion This study will develop standardised methods for electronic auscultation and chest ultrasound and compare their utility for detection of pneumonia to standard approaches. Utilising signal processing techniques, the authors aim to characterise lung sounds and through machine learning, develop a classification system to distinguish pathologic sounds. Data will allow a better understanding of the benefits and limitations of novel diagnostic techniques in paediatric pneumonia. PMID:22307098
Role of recoverin in rod photoreceptor light adaptation.
Morshedian, Ala; Woodruff, Michael L; Fain, Gordon L
2018-04-15
Recoverin is a small molecular-weight, calcium-binding protein in rod outer segments that can modulate the rate of rhodopsin phosphorylation. We describe two additional and perhaps more important functions during photoreceptor light adaptation. Recoverin influences the rate of change of adaptation. In wild-type rods, sensitivity and response integration time adapt with similar time constants of 150-200 ms. In Rv-/- rods lacking recoverin, sensitivity declines faster and integration time is already shorter and not significantly altered. During steady light exposure, rod circulating current slowly increases during a time course of tens of seconds, gradually extending the operating range of the rod. In Rv-/- rods, this mechanism is deleted, steady-state currents are already larger and rods saturate at brighter intensities. We propose that recoverin modulates spontaneous and light-activated phophodiesterase-6, the phototransduction effector enzyme, to increase sensitivity in dim light but improve responsiveness to change in brighter illumination. Recoverin is a small molecular-weight, calcium-binding protein in rod outer segments that binds to G-protein receptor kinase 1 and can alter the rate of rhodopsin phosphorylation. A change in phosphorylation should change the lifetime of light-activated rhodopsin and the gain of phototransduction, but deletion of recoverin has little effect on the sensitivity of rods either in the dark or in dim-to-moderate background light. We describe two additional functions perhaps of greater physiological significance. (i) When the ambient intensity increases, sensitivity and integration time decrease in wild-type (WT) rods with similar time constants of 150-200 ms. Recoverin is part of the mechanism controlling this process because, in Rv-/- rods lacking recoverin, sensitivity declines more rapidly and integration time is already shorter and not further altered. (ii) During steady light exposure, WT rod circulating current slowly increases during a time course of tens of seconds, gradually extending the operating range of the rod. In Rv-/- rods, this mechanism is also deleted, steady-state currents are already larger and rods saturate at brighter intensities. We argue that neither (i) nor (ii) can be caused by modulation of rhodopsin phosphorylation but may instead be produced by direct modulation of phophodiesterase-6 (PDE6), the phototransduction effector enzyme. We propose that recoverin in dark-adapted rods keeps the integration time long and the spontaneous PDE6 rate relatively high to improve sensitivity. In background light, the integration time is decreased to facilitate detection of change and motion and the spontaneous PDE6 rate decreases to augment the rod working range. © 2018 The Authors. The Journal of Physiology © 2018 The Physiological Society.
Computerization of guidelines: towards a "guideline markup language".
Dart, T; Xu, Y; Chatellier, G; Degoulet, P
2001-01-01
Medical decision making is one of the most difficult daily tasks for physicians. Guidelines have been designed to reduce variance between physicians in daily practice, to improve patient outcomes and to control costs. In fact, few physicians use guidelines in daily practice. A way to ease the use of guidelines is to implement computerised guidelines (computer reminders). We present in this paper a method of computerising guidelines. Our objectives were: 1) to propose a generic model that can be instantiated for any specific guidelines; 2) to use eXtensible Markup Language (XML) as a guideline representation language to instantiate the generic model for a specific guideline. Our model is an object representation of a clinical algorithm, it has been validated by running two different guidelines issued by a French official Agency. In spite of some limitations, we found that this model is expressive enough to represent complex guidelines devoted to diabetes and hypertension management. We conclude that XML can be used as a description format to structure guidelines and as an interface between paper-based guidelines and computer applications.
Improved nuclear fuel assembly grid spacer
Marshall, John; Kaplan, Samuel
1977-01-01
An improved fuel assembly grid spacer and method of retaining the basic fuel rod support elements in position within the fuel assembly containment channel. The improvement involves attachment of the grids to the hexagonal channel and of forming the basic fuel rod support element into a grid structure, which provides a design which is insensitive to potential channel distortion (ballooning) at high fluence levels. In addition the improved method eliminates problems associated with component fabrication and assembly.
CONTROL ROD FOR A NUCLEAR REACTOR AND METHOD OF PREPARATION
Hausner, H.H.
1958-12-30
BS>An improved control rod is presented for a nuclear reactor. This control rod is comprised of a rare earth metal oxide or rare earth metal carbide such as gadolinium oxide or gadolinium carbide, uniformly distributed in a metal matrix having a low cross sectional area of absorption for thermal neutrons, such as aluminum, beryllium, and zirconium.
A Computerized Wear Particle Atlas for Ferrogram and Filtergram Analyses
1998-01-01
A Computerised Wear Particle Atlas for Ferrogram and Filtergram Analyses Jian G. Ding Lubrosoft P/L P 0 Box 2368, Rowville Melbourne VIC 3178...Australia (61-3) 9759-9083 Abstract: A new computerised wear particle atlas has been developed for identification of solid particles and...differentiation of wear severity of lubricated equipment. This atlas contains 892 images of representative solid particles selected from thousands of filtergram
Rodriguez, Daniel M; Teesson, Maree; Newton, Nicola C
2014-03-01
Serious educational games (SEG) have been shown to be effective in educating young people about a range of topics, including languages and maths. This paper identifies the use of computerised SEGs in education about alcohol and other drugs and reviews their impact on the prevention of alcohol and drug use. The Cochrane Library, EMBASE, MEDLINE, ERIC, Scopus, psychINFO, pubMED and DRUG databases were searched in February 2013. Additional publications were obtained from the reference lists of the relevant papers. Studies were included if they described an evaluation of a computerised SEG that targeted alcohol and/or other drugs and had been trialled with adolescents. Eight SEGs were identified targeting tobacco, alcohol, cannabis, methamphetamine, ecstasy, inhalants, cocaine and opioids. Six reported positive outcomes in terms of increased content knowledge and two reported increased negative attitudes towards the targeted drugs. Only one reported a decrease in the frequency of drug use. This is the first review of the efficacy of computerised SEGs for alcohol and other drugs for adolescents. Results suggest that SEGs can increase content knowledge of alcohol and other drugs. Evidence concerning impacts on negative attitudes and alcohol and drug use is limited, with few studies examining these outcomes. © 2013 Australasian Professional Society on Alcohol and other Drugs.
Baker, Katharine S; Georgiou-Karistianis, Nellie; Lampit, Amit; Valenzuela, Michael; Gibson, Stephen J; Giummarra, Melita J
2018-04-01
Chronic pain is associated with reduced efficiency of cognitive performance, and few studies have investigated methods of remediation. We trialled a computerised cognitive training protocol to determine whether it could attenuate cognitive difficulties in a chronic pain sample. Thirty-nine adults with chronic pain (mean age = 43.3, 61.5% females) were randomised to an 8-week online course (3 sessions/week from home) of game-like cognitive training exercises, or an active control involving watching documentary videos. Participants received weekly supervision by video call. Primary outcomes were a global neurocognitive composite (tests of attention, speed, and executive function) and self-reported cognition. Secondary outcomes were pain (intensity; interference), mood symptoms (depression; anxiety), and coping with pain (catastrophising; self-efficacy). Thirty participants (15 training and 15 control) completed the trial. Mixed model intention-to-treat analyses revealed significant effects of training on the global neurocognitive composite (net effect size [ES] = 0.43, P = 0.017), driven by improved executive function performance (attention switching and working memory). The control group reported improvement in pain intensity (net ES = 0.65, P = 0.022). Both groups reported subjective improvements in cognition (ES = 0.28, P = 0.033) and catastrophising (ES = 0.55, P = 0.006). Depression, anxiety, self-efficacy, and pain interference showed no change in either group. This study provides preliminary evidence that supervised cognitive training may be a viable method for enhancing cognitive skills in persons with chronic pain, but transfer to functional and clinical outcomes remains to be demonstrated. Active control results suggest that activities perceived as relaxing or enjoyable contribute to improved perception of well-being. Weekly contact was pivotal to successful program completion.
Baskerville, J R; Chang, J H; Viator, M; Rutledge, W; Miryala, R; Duval, K E; Nishino, T K
2009-01-01
To determine the iatrogenic absorbed dosage of radiation of the patient in milligray (mGy) computerised tomography dose index volume (CTDIvol) when tested with multidetector computerised tomography (MDCT) in the emergency department (ED) setting and calculate the absorbed dosage of radiation per clinically actionable result and emergently treatable finding (ETF). The University of Texas Medical Branch (UTMB) ED located in Galveston, Texas, USA, is a level 1 trauma and tertiary referral centre treating 70,000 patients per annum. A retrospective cross-sectional data analysis of 770 emergency patients investigated by MDCT in July 2007. The presence of actionable results and ETF were determined by chart review. A total of 5320 emergency patients was treated in the UTMB ED in July 2007. This included 4508 medical and 812 trauma patients. A total of 1094 MDCT studies was performed, of which complete data were available on 1046. A total of 770 patients was investigated by MDCT, representing 14.47% of all emergency patients. This included 33.99% of trauma patients and 10.96% of medical patients. Actionable results were found in 341 studies and ETF in 105 studies. The mean radiation was 163.27 and 530.23 mGy CTDIvol for actionable results and ETF, respectively, for all studies. The mean radiation was 53.27 and 106.36 mGy CTDIvol for medical and trauma patients, respectively. The absorbed dosage of radiation of patients investigated by MDCT is clinically significant. The actionable results and ETF in our study demonstrate considerable opportunity for improvement in the utilisation of this technology by physicians.
Variation in sensitivity, absorption and density of the central rod distribution with eccentricity.
Tornow, R P; Stilling, R
1998-01-01
To assess the human rod photopigment distribution and sensitivity with high spatial resolution within the central +/-15 degrees and to compare the results of pigment absorption, sensitivity and rod density distribution (number of rods per square degree). Rod photopigment density distribution was measured with imaging densitometry using a modified Rodenstock scanning laser ophthalmoscope. Dark-adapted sensitivity profiles were measured with green stimuli (17' arc diameter, 1 degrees spacing) using a T ubingen manual perimeter. Sensitivity profiles were plotted on a linear scale and rod photopigment optical density distribution profiles were converted to absorption profiles of the rod photopigment layer. Both the absorption profile of the rod photopigment and the linear sensitivity profile for green stimuli show a minimum at the foveal center and increase steeply with eccentricity. The variation with eccentricity corresponds to the rod density distribution. Rod photopigment absorption profiles, retinal sensitivity profiles, and the rod density distribution are linearly related within the central +/-15 degrees. This is in agreement with theoretical considerations. Both methods, imaging retinal densitometry using a scanning laser ophthalmoscope and dark-adapted perimetry with small green stimuli, are useful for assessing the central rod distribution and sensitivity. However, at present, both methods have limitations. Suggestions for improving the reliability of both methods are given.
Shaw, P J; Allcutt, D A; Bates, D; Crawford, P J
1990-01-01
A case of cauda equina syndrome with multiple lumbar arachnoid cysts complicating ankylosing spondylitis (AS) is described. The value of computerised tomography (CT) and magnetic resonance imaging (MRI) as a non-invasive means of establishing the diagnosis is emphasised. In contrast to previously reported cases the patient showed neurological improvement following surgical therapy. Surgery may be indicated in some patients, particularly when there is nerve root compression by the arachnoid cysts and when the patient is seen early before irreversible damage to the cauda equina has occurred. Images PMID:2292702
Haque, Raqeeb M; Uddin, Omar M; Ahmed, Yousef; El Ahmadieh, Tarek Y; Hashmi, Sohaib Z; Shah, Amir; Fessler, Richard G
2016-10-01
Traditional open surgical techniques for correction of adult degenerative scoliosis (ADS) are often associated with increased blood loss, postoperative pain, and complications. Minimally invasive (MIS) techniques have been utilized to address these issues; however, concerns regarding improving certain alignment parameters have been raised. A new "push-through" technique for MIS correction of ADS has been developed wherein a rod is bent before its placement into the screw heads and then contoured further to yield improved correction of radiographic parameters. Preoperative and postoperative radiographic measurements of 3 patients who underwent MIS correction of scoliosis using the "push-through" technique were compared with 22 prior patients who had received traditional MIS correction. All patients received staged correction of scoliosis. The first stage involved insertion of lateral lumbar interbodies. Standing x-rays were then evaluated for overall global balance. The second stage involved appropriate MIS facetectomies, facet fusions, posterior transforaminal interbodies at lower lumbar segments, and finally the placement of rods.TECHNIQUE OVERVIEW:: (1) A long rod composed of titanium is bent with a mild lordosis and passed through the extensions of the screw heads cephalad to caudad. (2) The rod is passed fully through the incision so it extrudes from the caudal end of the construct. At this point, further lordosis is bent into the rods. (3) The rod is then pulled back into the appropriate position. (4) The unnecessary cephalad rod is then cut to appropriate length with a circular saw. (5) Rod reducers are then sequentially lowered and tightened to achieve the desired correction. Mean age for all patients was 66.02 years. Preoperative coronal Cobb, sagittal vertical axis (SVA), and pelvic incidence (PI) were similar in all patients, whereas lumbar lordosis (LL) was smaller (15.27 vs. 29.85 degrees, P=0.00389) and pelvic tilt (PT) was larger (37.00 vs. 27.00 degrees, P=0.00011) in "push-through" patients. Postoperatively, "pushthrough" patients experienced greater correction of LL (21.93 vs. 3.70 degrees, P=0.00001), PI-LL (-18.57 vs. -0.26 degrees, P=0.00471), PT (-7.67 vs. -0.40 degrees, P=0.00341), SVA (-40.67 mm vs. 0.95 mm, P=0.05846), and coronal Cobb (-20.23 vs. -18.76 degrees, P=0.75). This new method of contouring a rod enables improved LL. This technique is easy to perform and can be a valuable tool in treating ADS using MIS techniques.
Georgieva, A; Payne, S J; Redman, C W G
2009-12-01
The foetal heart rate (FHR) response to uterine contractions is crucial to detect foetal distress by electronic FHR monitoring during labour. We are developing a new automated system (OxSys) for decision support in labour, using the Oxford database of intrapartum FHR records. We describe here a novel technique for automated detection of uterus contractions. In addition, we present a comparison of the new method with four other computerised approaches. During training, OxSys achieved sensitivity above 95% and positive predictive value (PPV) of up to 90% for traces of good quality. During testing, OxSys achieved sensitivity = 87% and PPV = 75%. For comparison, a second clinical expert obtained sensitivity = 93% and PPV = 80%, and all other computerised approaches achieved lower values. It was concluded that the proposed method can be employed with confidence in our study on foetal health assessment in labour and future OxSys development.
Ultrasound control of magnet growing rod distraction in early onset scoliosis.
Pérez Cervera, T; Lirola Criado, J F; Farrington Rueda, D M
2016-01-01
The growing rod technique is currently one of the most common procedures used in the management of early onset scoliosis. However, in order to preserve spine growth and control the deformity it requires frequent surgeries to distract the rods. Magnetically driven growing rods have recently been introduced with same treatment goal, but without the inconvenience of repeated surgical distractions. One of the limitations of this technical advance is an increase in radiation exposure due to the increase in distraction frequency compared to conventional growing rods. An improvement of the original technique is presented, proposing a solution to the inconvenience of multiple radiation exposure using ultrasound technology to control the distraction process of magnetically driven growing rods. Copyright © 2014 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
Sigmundsdottir, Linda; Longley, Wendy A; Tate, Robyn L
2016-10-01
Computerised cognitive training (CCT) is an increasingly popular intervention for people experiencing cognitive symptoms. This systematic review evaluated the evidence for CCT in adults with acquired brain injury (ABI), focusing on how outcome measures used reflect efficacy across components of the International Classification of Functioning, Disability and Health. Database searches were conducted of studies investigating CCT to treat cognitive symptoms in adult ABI. Scientific quality was rated using the PEDro-P and RoBiNT Scales. Ninety-six studies met the criteria. Most studies examined outcomes using measures of mental functions (93/96, 97%); fewer studies included measures of activities/participation (41/96, 43%) or body structures (8/96, 8%). Only 14 studies (15%) provided Level 1 evidence (randomised controlled trials with a PEDro-P score ≥ 6/10), with these studies suggesting strong evidence for CCT improving processing speed in multiple sclerosis (MS) and moderate evidence for improving memory in MS and brain tumour populations. There is a large body of research examining the efficacy of CCT, but relatively few Level 1 studies and evidence is largely limited to body function outcomes. The routine use of outcome measures of activities/participation would provide more meaningful evidence for the efficacy of CCT. The use of body structure outcome measures (e.g., neuroimaging) is a newly emerging area, with potential to increase understanding of mechanisms of action for CCT.
Groom, Madeleine J; Young, Zoe; Hall, Charlotte L; Gillott, Alinda; Hollis, Chris
2016-09-30
There is a clinical need for objective evidence-based measures that are sensitive and specific to ADHD when compared with other neurodevelopmental disorders. This study evaluated the incremental validity of adding an objective measure of activity and computerised cognitive assessment to clinical rating scales to differentiate adult ADHD from Autism spectrum disorders (ASD). Adults with ADHD (n=33) or ASD (n=25) performed the QbTest, comprising a Continuous Performance Test with motion-tracker to record physical activity. QbTest parameters measuring inattention, impulsivity and hyperactivity were combined to provide a summary score ('QbTotal'). Binary stepwise logistic regression measured the probability of assignment to the ADHD or ASD group based on scores on the Conners Adult ADHD Rating Scale-subscale E (CAARS-E) and Autism Quotient (AQ10) in the first step and then QbTotal added in the second step. The model fit was significant at step 1 (CAARS-E, AQ10) with good group classification accuracy. These predictors were retained and QbTotal was added, resulting in a significant improvement in model fit and group classification accuracy. All predictors were significant. ROC curves indicated superior specificity of QbTotal. The findings present preliminary evidence that adding QbTest to clinical rating scales may improve the differentiation of ADHD and ASD in adults. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Small diameter, deep bore optical inspection system
Lord, David E.; Petrini, Richard R.; Carter, Gary W.
1981-01-01
An improved rod optic system for inspecting small diameter, deep bores. The system consists of a rod optic system utilizing a curved mirror at the end of the rod lens such that the optical path through the system is bent 90.degree. to minimize optical distortion in examining the sides of a curved bore. The system is particularly useful in the examination of small bores for corrosion, and is capable of examining 1/16 inch diameter and up to 4 inch deep drill holes, for example. The positioning of the curved mirror allows simultaneous viewing from shallow and right angle points of observation of the same artifact (such as corrosion) in the bore hole. The improved rod optic system may be used for direct eye sighting, or in combination with a still camera or a low-light television monitor; particularly low-light color television.
Structural Integrity Testing Method for PRSEUS Rod-Wrap Stringer Design
NASA Technical Reports Server (NTRS)
Wang, John T.; Grenoble, Ray W.; Pickell, Robert D.
2012-01-01
NASA Langley Research Center and The Boeing Company are developing an innovative composite structural concept, called PRSEUS, for the flat center section of a future environmentally friendly hybrid wing body (HWB) aircraft. The PRSEUS (Pultruded Rod Stitched Efficient Unitized Structure) concept uses dry textile preforms for the skins, frames, and stiffener webs. The highly loaded stiffeners are made from precured unidirectional carbon/epoxy rods and dry fiber preforms. The rods are wrapped with the dry fiber preforms and a resin infusion process is used to form the rod-wrap stiffeners. The structural integrity of the rod-wrap interface is critical for maintaining the panel s high strength and bending rigidity. No standard testing method exists for testing the strength of the rod-wrap bondline. Recently, Boeing proposed a rod push-out testing method and conducted some preliminary tests using this method. This paper details an analytical study of the rod-wrap bondline. The rod-wrap interface is modeled as a cohesive zone for studying the initiation and growth of interfacial debonding during push-out testing. Based on the correlations of analysis results and Boeing s test data, the adequacy of the rod-wrap testing method is evaluated, and potential approaches for improvement of the test method are proposed.
Palmer, Rebecca; Cooper, Cindy; Enderby, Pam; Brady, Marian; Julious, Steven; Bowen, Audrey; Latimer, Nicholas
2015-01-27
Aphasia affects the ability to speak, comprehend spoken language, read and write. One third of stroke survivors experience aphasia. Evidence suggests that aphasia can continue to improve after the first few months with intensive speech and language therapy, which is frequently beyond what resources allow. The development of computer software for language practice provides an opportunity for self-managed therapy. This pragmatic randomised controlled trial will investigate the clinical and cost effectiveness of a computerised approach to long-term aphasia therapy post stroke. A total of 285 adults with aphasia at least four months post stroke will be randomly allocated to either usual care, computerised intervention in addition to usual care or attention and activity control in addition to usual care. Those in the intervention group will receive six months of self-managed word finding practice on their home computer with monthly face-to-face support from a volunteer/assistant. Those in the attention control group will receive puzzle activities, supplemented by monthly telephone calls. Study delivery will be coordinated by 20 speech and language therapy departments across the United Kingdom. Outcome measures will be made at baseline, six, nine and 12 months after randomisation by blinded speech and language therapist assessors. Primary outcomes are the change in number of words (of personal relevance) named correctly at six months and improvement in functional conversation. Primary outcomes will be analysed using a Hochberg testing procedure. Significance will be declared if differences in both word retrieval and functional conversation at six months are significant at the 5% level, or if either comparison is significant at 2.5%. A cost utility analysis will be undertaken from the NHS and personal social service perspective. Differences between costs and quality-adjusted life years in the three groups will be described and the incremental cost effectiveness ratio will be calculated. Treatment fidelity will be monitored. This is the first fully powered trial of the clinical and cost effectiveness of computerised aphasia therapy. Specific challenges in designing the protocol are considered. Registered with Current Controlled Trials ISRCTN68798818 on 18 February 2014.
Method of fabricating composite superconducting wire
Strauss, Bruce P.; Reardon, Paul J.; Remsbottom, Robert H.
1977-01-01
An improvement in the method for preparing composite rods of superconducting alloy and normal metal from which multifilament composite superconducting wire is fabricated by bending longitudinally a strip of normal metal around a rod of superconductor alloy and welding the edges to form the composite rod. After the rods have preferably been provided with a hexagonal cross-sectional shape, a plurality of the rods are stacked into a normal metal extrusion can, sealed and worked to reduce the cross-sectional size and form multifilament wire. Diffusion barriers and high-electrical resistance barriers can easily be introduced into the wire by plating or otherwise coating the faces of the normal metal strip with appropriate materials.
NASA Technical Reports Server (NTRS)
Robinson, E. D.; Waterman, A. W.; Nelson, W. G.
1972-01-01
Polyimide second stage rod seals were evaluated to determine their suitability for application in advanced aircraft systems. The configurations of the seals are described. The conditions of the life cycle tests are provided. It was determined that external rod seal leakage was within prescribed limits and that the seals showed no signs of structural degradation.
Design and Analysis of Wind Turbine Rotors Using Hinged Structures and Rods
NASA Astrophysics Data System (ADS)
Lu, Hongya; Zeng, Pan; Lei, Liping
2018-03-01
Light weight and high stiffness are key design factors in ensuring cost effectiveness and reliability of wind turbines, especially for the inboard region of the rotor blades. In this study, several novel designs were developed to improve the mechanical performance of the rotor. Experiments were performed on an isolated blade incorporating the new features of a hinged structure and rods. The results validated the effectiveness of these features at alleviating the root-bending moment of the blade under varying wind loads and enhancing the stiffness of the blade. A numerical investigation was carried out to further examine the bending moment distribution, shear and axial force, and rod tension of these novel rotor designs under uniform loads. Longitudinal geometrical variations of the blade were considered in the model. Results showed that two designs realized a favorable bending moment distribution and improved the modal frequencies of the edgewise modes: bisymmetrical rods on a single-hinged structure and interveined symmetrical rods on a cantilevered structure. However, these designs have different deformation mechanisms. In addition, the first group of edgewise modal frequencies of these two designs were improved compared with the traditional rotor design. Their potential values in the application to the design of a lightweight, high-stiffness, and reliable wind turbine rotor were discussed.
NASA Astrophysics Data System (ADS)
Das, Priyanka; Mondal, Biswanath; Mukherjee, Kalisadhan
2018-01-01
Present article describes the DSSC performances of photo-anodes prepared using hydrothermal route derived ZnO particles having dissimilar morphologies i.e. simple micro-rod and nano-tips decorated micro-rod. The surface of nano-tips decorated micro-rod is uneven and patterned which facilitate more dye adsorption and better scattering of the incident light resulting superior photo-conversion efficiency (PCE) ( η 1.09%) than micro-rod ZnO ( η 0.86%). To further improve the efficiency of nano-tips decorated micro-rod ZnO based DSSC, thin passivation layer of ZnO is introduced in the corresponding photo-anode and a higher PCE ( η 1.29%) is achieved. The compact thin passivation layer here expedites the transportation of photo-excited electrons, restricts the undesired recombination reactions and prevents the direct contact of electrolyte with conducting substrates. Attempt is made to understand the effect of passivation layer on the transportation kinetics of photo-excited electrons by analyzing the electrochemical impedance spectra of the developed cells.
Boaz, Annette; Baeza, Juan; Fraser, Alec
2011-06-22
The gap between research findings and clinical practice is well documented and a range of interventions has been developed to increase the implementation of research into clinical practice. A review of systematic reviews of the effectiveness of interventions designed to increase the use of research in clinical practice. A search for relevant systematic reviews was conducted of Medline and the Cochrane Database of Reviews 1998-2009. 13 systematic reviews containing 313 primary studies were included. Four strategy types are identified: audit and feedback; computerised decision support; opinion leaders; and multifaceted interventions. Nine of the reviews reported on multifaceted interventions. This review highlights the small effects of single interventions such as audit and feedback, computerised decision support and opinion leaders. Systematic reviews of multifaceted interventions claim an improvement in effectiveness over single interventions, with effect sizes ranging from small to moderate. This review found that a number of published systematic reviews fail to state whether the recommended practice change is based on the best available research evidence. This overview of systematic reviews updates the body of knowledge relating to the effectiveness of key mechanisms for improving clinical practice and service development. Multifaceted interventions are more likely to improve practice than single interventions such as audit and feedback. This review identified a small literature focusing explicitly on getting research evidence into clinical practice. It emphasizes the importance of ensuring that primary studies and systematic reviews are precise about the extent to which the reported interventions focus on changing practice based on research evidence (as opposed to other information codified in guidelines and education materials).
Multi-channel and porous SiO@N-doped C rods as anodes for high-performance lithium-ion batteries
NASA Astrophysics Data System (ADS)
Huang, Xiao; Li, Mingqi
2018-05-01
To improve the cycling stability and rate capability of SiO electrodes, multi-channel and porous SiO@N-doped C (mp-SiO@N-doped C) rods are fabricated by the combination of electrospinning and heat treatment with the assistance of poly(methyl methacrylate) (PMMA). During annealing, in-situ PMMA degradation and gasification lead to the formation of multi-channel structure and more pores. As anodes for lithium ion batteries, the mp-SiO@N-doped C rods exhibit excellent cycling stability. At a current density of 400 mA g-1, a discharge capacity of 806 mAh g-1 can be kept after 250 cycles, the retention of which is over than 100% versus the initial reversible capacity. Compared with the SiO@N-doped C rods synthesized without the help of PMMA, the mp-SiO@N-doped C rods exhibit more excellent rate capability. The excellent electrochemical performance is attributed to the special structure of the mp-SiO@N-doped C rods. In addition to the conductivity improved by carbon fibers, the multi-channel and porous structures not only make ions/electrons transfer and electrolyte diffusion easier, but also contribute to the structural stability of the electrodes.
Small diameter, deep bore optical inspection system
Lord, D.E.; Petrini, R.R.; Carter, G.W.
An improved rod optic system for inspecting small diameter, deep bores is described. The system consists of a rod optic system utilizing a curved mirror at the end of the rod lens such that the optical path through the system is bent 90/sup 0/ to minimize optical distortion in examing the sides of a curved bore. The system is particularly useful in the examination of small bores for corrosion, and is capable if examing 1/16 inch diameter and up to 4-inch deep drill holes, for example. The positioning of the curved mirror allows simultaneous viewing from shallow and righ angle points of observation of the same artifact (such as corrosion) in the bore hole. The improved rod optic system may be used for direct eye sighting, or in combination with a still camera or a low-light television monitor; particularly low-light color television.
Huang, Zifang; Wang, Chongwen; Fan, Hengwei; Sui, Wenyuan; Li, Xueshi; Wang, Qifei; Yang, Junlin
2017-07-28
Screw-rod constructs have been widely used to correct spinal deformities, but the effects of different screw-rod systems on anti-rotational torque have not been determined. This study aimed to analyze the biomechanical effect of different rod-screw constructs on anti-rotational torque. Three conventional spinal screw-rod systems (Legacy, RF-F-10 and USSII) were used to test the anti-rotational torque in the material test machine. ANOVA was performed to evaluate the anti-rotational capacity of different pedicle screws-rod constructs. The anti-rotational torque of Legacy group, RF-F-10 group and USSII group were 12.3 ± 1.9 Nm, 6.8 ± 0.4 Nm, and 3.9 ± 0.8 Nm, with a P value lower than 0.05. This results indicated that the Legacy screws-rod construct could provide a highest anti-rotation capacity, which is 68% and 210% greater than RF-F-10 screw-rod construct and USSII screw-rod respectively. The anti-rotational torque may be mainly affected by screw cap and groove design. Our result showed the anti-rotational torque are: Legacy system > RF-F-10 system > USSII system, suggesting that appropriate rod-screw constructs selection in surgery may be vital for anti-rotational torque improvement and preventing derotation correction loss.
INRstar: computerised decision support software for anticoagulation management in primary care.
Jones, Robert Treharne; Sullivan, Mark; Barrett, David
2005-01-01
Computerised decision support software (CDSS) for anticoagulation management has become established practice in the UK, offering significant advantages for patients and clinicians over traditional methods of dose calculation. The New GMS Contract has been partly responsible for this shift of management from secondary to primary care, in which INRstar has been the market leader for many years. In September 2004, INRstar received the John Perry Prize, awarded by the PHCSG for excellence and innovation in medical applications of information technology.
An improved equivalent circuit model of a four rod deflecting cavity
NASA Astrophysics Data System (ADS)
Apsimon, R.; Burt, G.
2017-03-01
In this paper we present an improved equivalent circuit model for a four rod deflecting cavity which calculates the frequencies of the first four modes of the cavity as well as the RT/Q for the deflecting mode. Equivalent circuit models of RF cavities give intuition and understanding about how the cavity operates and what changes can be made to modify the frequency, without the need for RF simulations, which can be time-consuming. We parameterise a generic four rod deflecting cavity into a geometry consisting of simple shapes. Equations are derived for the line impedance of the rods and the capacitance between the rods and these are used to calculate the resonant frequency of the deflecting dipole mode as well as the lower order mode and the model is bench-marked against two test cases; the CEBAF separator and the HL-LHC 4-rod LHC crab cavity. CST and the equivalent circuit model agree within 4% for both cavities with the LOM frequency and within 1% for the deflecting frequency. RT/Q differs between the model and CST by 37% for the CEBAF separator and 25% for the HL-LHC 4-rod crab cavity; however this is sufficient for understanding how to optimise the cavity design. The model has then been utilised to suggest a method of separating the modal frequencies in the HL-LHC crab cavity and to suggest design methodologies to optimise the cavity geometries.
Method and device for tensile testing of cable bundles
Robertson, Lawrence M; Ardelean, Emil V; Goodding, James C; Babuska, Vit
2012-10-16
A standard tensile test device is improved to accurately measure the mechanical properties of stranded cables, ropes, and other composite structures wherein a witness is attached to the top and bottom mounting blocks holding the cable under test. The witness is comprised of two parts: a top and a bottom rod of similar diameter with the bottom rod having a smaller diameter stem on its upper end and the top rod having a hollow opening in its lower end into which the stem fits forming a witness joint. A small gap is present between the top rod and the larger diameter portion of the bottom rod. A standard extensometer is attached to the top and bottom rods of the witness spanning this small witness gap. When a force is applied to separate the mounting blocks, the gap in the witness expands the same length that the entire test specimen is stretched.
Van der Molen, M J; Van Luit, J E H; Van der Molen, M W; Klugkist, I; Jongmans, M J
2010-05-01
The goal of this study is to evaluate the effectiveness of a computerised working memory (WM) training on memory, response inhibition, fluid intelligence, scholastic abilities and the recall of stories in adolescents with mild to borderline intellectual disabilities attending special education. A total of 95 adolescents with mild to borderline intellectual disabilities were randomly assigned to either a training adaptive to each child's progress in WM, a non-adaptive WM training, or to a control group. Verbal short-term memory (STM) improved significantly from pre- to post-testing in the group who received the adaptive training compared with the control group. The beneficial effect on verbal STM was maintained at follow-up and other effects became clear at that time as well. Both the adaptive and non-adaptive WM training led to higher scores at follow-up than at post-intervention on visual STM, arithmetic and story recall compared with the control condition. In addition, the non-adaptive training group showed a significant increase in visuo-spatial WM capacity. The current study provides the first demonstration that WM can be effectively trained in adolescents with mild to borderline intellectual disabilities.
Luminescent Properties of Eu(III) Chelates on Metal Nanorods
Zhang, Jian; Fu, Yi; Ray, Krishanu; Wang, Yuan; Lakowicz, Joseph. R.
2013-01-01
In this article, we report the change of optical properties for europium chelates on silver nanorods by near-field interactions. The silver rods were fabricated in a seed-growth method followed by depositing thin layers of silica on the surfaces. The europium chelates were physically absorbed in the silica layers on the silver rods. The silver rods were observed to exhibit two plasmon absorption bands from longitudinal and transverse directions, respectively, centered at 394 and 675 nm, close to absorption and emission bands from the Eu(III) chelates. As a result, the immobilized Eu(III) chelates on the silver rods should have strong interactions with the silver nanorods and lead to greatly improved optical properties. The Eu–Ag rod complexes were observed to have enhanced emission intensity up to 240-fold in comparison with the Eu(III) chelates in the metal-free silica templates. This enhancement is much larger than the value for the Eu(III) chelates on the gold rods or silver spheres indicating the presence of stronger interactions for the Eu(III) chelates with the silver rods. The interactions of Eu(III) chelates with the silver rods were also proven by extremely reduced lifetime. Moreover, the Eu–Ag rod complexes exhibited a polarized emission, which was also due to strong interactions of the Eu(III) chelates with the silver rods. All of these features may promise that the Eu(III)–Ag rod complexes have great potential for use as fluorescence imaging agents in biological assays. PMID:24363816
Computerised decision support in physical activity interventions: A systematic literature review.
Triantafyllidis, Andreas; Filos, Dimitris; Claes, Jomme; Buys, Roselien; Cornelissen, Véronique; Kouidi, Evangelia; Chouvarda, Ioanna; Maglaveras, Nicos
2018-03-01
The benefits of regular physical activity for health and quality of life are unarguable. New information, sensing and communication technologies have the potential to play a critical role in computerised decision support and coaching for physical activity. We provide a literature review of recent research in the development of physical activity interventions employing computerised decision support, their feasibility and effectiveness in healthy and diseased individuals, and map out challenges and future research directions. We searched the bibliographic databases of PubMed and Scopus to identify physical activity interventions with computerised decision support utilised in a real-life context. Studies were synthesized according to the target user group, the technological format (e.g., web-based or mobile-based) and decision-support features of the intervention, the theoretical model for decision support in health behaviour change, the study design, the primary outcome, the number of participants and their engagement with the intervention, as well as the total follow-up duration. From the 24 studies included in the review, the highest percentage (n = 7, 29%) targeted sedentary healthy individuals followed by patients with prediabetes/diabetes (n = 4, 17%) or overweight individuals (n = 4, 17%). Most randomized controlled trials reported significantly positive effects of the interventions, i.e., increase in physical activity (n = 7, 100%) for 7 studies assessing physical activity measures, weight loss (n = 3, 75%) for 4 studies assessing diet, and reductions in glycosylated hemoglobin (n = 2, 66%) for 3 studies assessing glycose concentration. Accelerometers/pedometers were used in almost half of the studies (n = 11, 46%). Most adopted decision support features included personalised goal-setting (n = 16, 67%) and motivational feedback sent to the users (n = 15, 63%). Fewer adopted features were integration with electronic health records (n = 3, 13%) and alerts sent to caregivers (n = 4, 17%). Theoretical models of decision support in health behaviour to drive the development of the intervention were not reported in most studies (n = 14, 58%). Interventions employing computerised decision support have the potential to promote physical activity and result in health benefits for both diseased and healthy individuals, and help healthcare providers to monitor patients more closely. Objectively measured activity through sensing devices, integration with clinical systems used by healthcare providers and theoretical frameworks for health behaviour change need to be employed in a larger scale in future studies in order to realise the development of evidence-based computerised systems for physical activity monitoring and coaching. Copyright © 2017 Elsevier B.V. All rights reserved.
Extraction electrode geometry for a calutron
Veach, A.M.; Bell, W.A. Jr.
1975-09-23
This patent relates to an improved geometry for the extraction electrode and the ground electrode utilized in the operation of a calutron. The improved electrodes are constructed in a partial-picture-frame fashion with the slits of both electrodes formed by two tungsten elongated rods. Additional parallel spaced-apart rods in each electrode are used to establish equipotential surfaces over the rest of the front of the ion source. (auth)
NASA Astrophysics Data System (ADS)
Porter, Ian Edward
A nuclear reactor systems code has the ability to model the system response in an accident scenario based on known initial conditions at the onset of the transient. However, there has been a tendency for these codes to lack the detailed thermo-mechanical fuel rod response models needed for accurate prediction of fuel rod failure. This proposed work will couple today's most widely used steady-state (FRAPCON) and transient (FRAPTRAN) fuel rod models with a systems code TRACE for best-estimate modeling of system response in accident scenarios such as a loss of coolant accident (LOCA). In doing so, code modifications will be made to model gamma heating in LWRs during steady-state and accident conditions and to improve fuel rod thermal/mechanical analysis by allowing axial nodalization of burnup-dependent phenomena such as swelling, cladding creep and oxidation. With the ability to model both burnup-dependent parameters and transient fuel rod response, a fuel dispersal study will be conducted using a hypothetical accident scenario under both PWR and BWR conditions to determine the amount of fuel dispersed under varying conditions. Due to the fuel fragmentation size and internal rod pressure both being dependent on burnup, this analysis will be conducted at beginning, middle and end of cycle to examine the effects that cycle time can play on fuel rod failure and dispersal. Current fuel rod and system codes used by the Nuclear Regulatory Commission (NRC) are compilations of legacy codes with only commonly used light water reactor materials, Uranium Dioxide (UO2), Mixed Oxide (U/PuO 2) and zirconium alloys. However, the events at Fukushima Daiichi and Three Mile Island accident have shown the need for exploration into advanced materials possessing improved accident tolerance. This work looks to further modify the NRC codes to include silicon carbide (SiC), an advanced cladding material proposed by current DOE funded research on accident tolerant fuels (ATF). Several additional fuels will also be analyzed, including uranium nitride (UN), uranium carbide (UC) and uranium silicide (U3Si2). Focusing on the system response in an accident scenario, an emphasis is placed on the fracture mechanics of the ceramic cladding by design the fuel rods to eliminate pellet cladding mechanical interaction (PCMI). The time to failure and how much of the fuel in the reactor fails with an advanced fuel design will be analyzed and compared to the current UO2/Zircaloy design using a full scale reactor model.
Fritz, Gregory M.; Weihs, Timothy P.; Grzyb, Justin A.
2016-07-05
An energetic composite having a plurality of reactive particles each having a reactive multilayer construction formed by successively depositing reactive layers on a rod-shaped substrate having a longitudinal axis, dividing the reactive-layer-deposited rod-shaped substrate into a plurality of substantially uniform longitudinal segments, and removing the rod-shaped substrate from the longitudinal segments, so that the reactive particles have a controlled, substantially uniform, cylindrically curved or otherwise rod-contoured geometry which facilitates handling and improves its packing fraction, while the reactant multilayer construction controls the stability, reactivity and energy density of the energetic composite.
Fritz, Gregory M; Knepper, Robert Allen; Weihs, Timothy P; Gash, Alexander E; Sze, John S
2013-04-30
An energetic composite having a plurality of reactive particles each having a reactive multilayer construction formed by successively depositing reactive layers on a rod-shaped substrate having a longitudinal axis, dividing the reactive-layer-deposited rod-shaped substrate into a plurality of substantially uniform longitudinal segments, and removing the rod-shaped substrate from the longitudinal segments, so that the reactive particles have a controlled, substantially uniform, cylindrically curved or otherwise rod-contoured geometry which facilitates handling and improves its packing fraction, while the reactant multilayer construction controls the stability, reactivity and energy density of the energetic composite.
Mathematical models for determining the protected spaces of the vertical lightning rod
NASA Technical Reports Server (NTRS)
Mladenovic, I.; Vorgucic, A.
1991-01-01
Two mathematical models are presented for determining the protected spaces of the vertical lightning-rod. In the first model there was applied the circular approximation. Through the introduction of the modified striking distance in the second improved approximation there was obtained a new model for the protected space of the lightning-rod. The models are of general type, foreseen for the three-dimensional space and they are simply applied on solving the practical problems.
Desai, K M; Gingell, J C; Skidmore, R; Follett, D H
1987-11-01
A new method is described for evaluating arteriogenic impotence by means of noninvasive quantification of penile Doppler arterial waveforms using computerised analysis based on the Laplace Transform model. The haemodynamic changes occurring during a papaverine-induced erection in healthy potent volunteers have been recorded by this technique, which has also been shown to be capable of discriminating between a normal and an abnormal penile arterial supply in an initial study of potent and impotent men.
de Lusignan, Simon; Liaw, Siaw-Teng; Dedman, Daniel; Khunti, Kamlesh; Sadek, Khaled; Jones, Simon
2015-06-05
An algorithm that detects errors in diagnosis, classification or coding of diabetes in primary care computerised medial record (CMR) systems is currently available. However, this was developed on CMR systems that are episode orientated medical records (EOMR); and do not force the user to always code a problem or link data to an existing one. More strictly problem orientated medical record (POMR) systems mandate recording a problem and linking consultation data to them. To compare the rates of detection of diagnostic accuracy using an algorithm developed in EOMR with a new POMR specific algorithm. We used data from The Health Improvement Network (THIN) database (N = 2,466,364) to identify a population of 100,513 (4.08%) patients considered likely to have diabetes. We recalibrated algorithms designed to classify cases of diabetes to take account of that POMR enforced coding consistency in the computerised medical record systems [In Practice Systems (InPS) Vision] that contribute data to THIN. We explored the different proportions of people classified as having type 1 diabetes mellitus (T1DM) or type 2 diabetes mellitus (T2DM) and with diabetes unclassifiable as either T1DM or T2DM. We compared proportions using chi-square tests and used Tukey's test to compare the characteristics of the people in each group. The prevalence of T1DM using the original EOMR algorithm was 0.38% (9,264/2,466,364), and for T2DM 3.22% (79,417/2,466,364). The prevalence using the new POMR algorithm was 0.31% (7,750/2,466,364) T1DM and 3.65% (89,990/2,466,364) T2DM. The EOMR algorithms also left more people unclassified 11,439 (12%), as to their type of diabetes compared with 2,380 (2.4%), for the new algorithm. Those people who were only classified by the EOMR system differed in terms of older age, and apparently better glycaemic control, despite not being prescribed medication for their diabetes (p < 0.005). Increasing the degree of problem orientation of the medical record system can improve the accuracy of recording of diagnoses and, therefore, the accuracy of using routinely collected data from CMRs to determine the prevalence of diabetes mellitus; data processing strategies should reflect the degree of problem orientation.
Ohira, Shingo; Kanayama, Naoyuki; Wada, Kentaro; Karino, Tsukasa; Nitta, Yuya; Ueda, Yoshihiro; Miyazaki, Masayoshi; Koizumi, Masahiko; Teshima, Teruki
2018-04-02
The objective of this study was to assess the accuracy of the quantitative measurements obtained using dual-energy computed tomography with metal artifact reduction software (MARS). Dual-energy computed tomography scans (fast kV-switching) are performed on a phantom, by varying the number of metal rods (Ti and Pb) and reference iodine materials. Objective and subjective image analyses are performed on retroreconstructed virtual monochromatic images (VMIs) (VMI at 70 keV). The maximum artifact indices for VMI-Ti and VMI-Pb (5 metal rods) with MARS (without MARS) were 17.4 (166.7) and 34.6 (810.6), respectively; MARS significantly improved the mean subjective 5-point score (P < 0.05). The maximum differences between the measured Hounsfield unit and theoretical values for 5 mg/mL iodine and 2-mm core rods were -42.2% and -68.5%, for VMI-Ti and VMI-Pb (5 metal rods), respectively, and the corresponding differences in the iodine concentration were -64.7% and -73.0%, respectively. Metal artifact reduction software improved the objective and subjective image quality; however, the quantitative values were underestimated.
Luo, Chan; Jiang, Dan; Ding, Chuan-Fan; Konenkov, Nikolai V
2009-09-01
Numeric experiments were performed to study the first and second stability regions and find the optimal configurations of a quadrupole mass filter constructed of circular quadrupole rods with a rectangular wave power supply. The ion transmission contours were calculated using ion trajectory simulations. For the first stability region, the optimal rod set configuration and the ratio r/r(0) is 1.110-1.115; for the second stability region, it is 1.128-1.130. Low-frequency direct current (DC) modulation with the parameters of m = 0.04-0.16 and nu = omega/Omega = 1/8-1/14 improves the mass peak shape of the circular rod quadrupole mass filter at the optimal r/r(0) ratio of 1.130. The amplitude modulation does not improve mass peak shape. Copyright (c) 2009 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Q. Y.; Hu, T.; Kwok, Dixon T. K.
2010-05-15
Owing to the nonconformal plasma sheath in plasma immersion ion implantation of a rod sample, the retained dose can vary significantly. The authors propose to improve the implant uniformity by introducing a metal mesh. The depth profiles obtained with and without the mesh are compared and the implantation temperature at various locations is evaluated indirectly by differential scanning calorimeter. Our results reveal that by using the metal mesh, the retained dose uniformity along the length is greatly improved and the effects of the implantation temperature on the localized mechanical properties of the implanted NiTi shape memory alloy rod are nearlymore » negligible.« less
Multi-Fresnel lenses pumping approach for improving high-power Nd:YAG solar laser beam quality.
Liang, Dawei; Almeida, Joana
2013-07-20
To significantly improve the present-day high-power solar laser beam quality, a three-stage multi-Fresnel lenses approach is proposed for side-pumping either a Nd:YAG single-crystal or a core-doped Sm(3+)Nd:YAG ceramic rod. Optimum pumping and laser beam parameters are found through ZEMAX and LASCAD numerical analysis. The proposed scheme offers a uniform absorption profile along the rod. 167 W laser power can be achieved, corresponding to 29.3 W/m(2) collection efficiency. High brightness figure of merit of 8.34 W is expected for the core-doped rod within a convex-concave resonator, which is 1300 times higher than that of the most-recent high-power solar laser.
Moore, L; Tapper, K; Dennehy, A; Cooper, A
2005-07-01
To evaluate the validity, reliability and sensitivity of a computerised single day 24-h recall questionnaire designed for the comparison of children's fruit and snack consumption at the group (school) level. Relative validity and reliability were assessed in relation to (i) intake at school and (ii) intake throughout the whole day, using diary-assisted 24-h recall interviews and a 7-day test-retest procedure. Sensitivity was assessed in relation to intake by comparing results from schools with differing food policies, and by sex. Eight schools took part in the validity and reliability assessments, with 78 children completing the 24-h recall interviews and 195 children completing the test-retest procedure. A total of 43 schools (1890 children) took part in the sensitivity analysis. All children were aged 9-11 y. All schools were in South Wales and South-west England. For fruit intake at school, the questionnaire showed fair levels of validity at the individual level (kappa = 0.29). At the group level, there were little or no differences in fruit intake at school between the two measures and two occasions. The questionnaire was sufficiently sensitive to identify statistically significant differences between girls and boys, and between schools with different food policies. For snack intake at school, validity at the individual level was slightly lower (kappa = 0.220.25), but the data remained of value in analyses at the group level. For fruit and snack intake throughout the whole day there was little agreement at the individual level (kappa = 0.00-0.06), and at the group level there tended to be substantial differences between the two measures and two occasions. The computerised questionnaire is a quick and cost-effective means of assessing children's consumption of fruit at school. While further development is required to improve validity and reliability, it has the potential to be particularly useful in randomised controlled trials of school-based dietary interventions.
Process-based tolerance assessment of connecting rod machining process
NASA Astrophysics Data System (ADS)
Sharma, G. V. S. S.; Rao, P. Srinivasa; Surendra Babu, B.
2016-06-01
Process tolerancing based on the process capability studies is the optimistic and pragmatic approach of determining the manufacturing process tolerances. On adopting the define-measure-analyze-improve-control approach, the process potential capability index ( C p) and the process performance capability index ( C pk) values of identified process characteristics of connecting rod machining process are achieved to be greater than the industry benchmark of 1.33, i.e., four sigma level. The tolerance chain diagram methodology is applied to the connecting rod in order to verify the manufacturing process tolerances at various operations of the connecting rod manufacturing process. This paper bridges the gap between the existing dimensional tolerances obtained via tolerance charting and process capability studies of the connecting rod component. Finally, the process tolerancing comparison has been done by adopting a tolerance capability expert software.
Prosthetic Hand For Holding Rods, Tools, And Handles
NASA Technical Reports Server (NTRS)
Belcher, Jewell G., Jr.; Vest, Thomas W.
1995-01-01
Prosthetic hand with quick-grip/quick-release lever broadens range of specialized functions available to lower-arm amputee by providing improved capabilities for gripping rods, tools, handles, and like. Includes two stationary lower fingers opposed by one pivoting upper finger. Lever operates in conjunction with attached bracket.
ZIRCONIA RODS FOR COATING ARTICLES BY FLAME SPRAYING
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1960-04-21
An improved ZrO/sub 2/ rod for flame spraying guns is described which consists of a sintered ZrO/sub 2/ rod of mostly cubic and tetragonal crystals and has a porosity of 8% to 40% by volume. These rods are prepared by mixing 100 parts of ZrO/sub 2/ 75 parts fused, stabilized, 216 mu size, containing 5% CaO, 15 parts fused, stabilized, 25 to 50 mu size, with 5% CaO, 10 parts fused, unstabilized lime-free with 17 parts water, 1 part dextrine, 2 parts corn starch, and extruding. They are then dried and fired in a kiln heated to cone 35 Orton.more » (T.R.H.)« less
NASA Astrophysics Data System (ADS)
Zhang, Hao; Gang, Grace J.; Lee, Junghoon; Wong, John; Stayman, J. Webster
2017-03-01
Purpose: There are many clinical situations where diagnostic CT is used for an initial diagnosis or treatment planning, followed by one or more CBCT scans that are part of an image-guided intervention. Because the high-quality diagnostic CT scan is a rich source of patient-specific anatomical knowledge, this provides an opportunity to incorporate the prior CT image into subsequent CBCT reconstruction for improved image quality. We propose a penalized-likelihood method called reconstruction of difference (RoD), to directly reconstruct differences between the CBCT scan and the CT prior. In this work, we demonstrate the efficacy of RoD with clinical patient datasets. Methods: We introduce a data processing workflow using the RoD framework to reconstruct anatomical changes between the prior CT and current CBCT. This workflow includes processing steps to account for non-anatomical differences between the two scans including 1) scatter correction for CBCT datasets due to increased scatter fractions in CBCT data; 2) histogram matching for attenuation variations between CT and CBCT; and 3) registration for different patient positioning. CBCT projection data and CT planning volumes for two radiotherapy patients - one abdominal study and one head-and-neck study - were investigated. Results: In comparisons between the proposed RoD framework and more traditional FDK and penalized-likelihood reconstructions, we find a significant improvement in image quality when prior CT information is incorporated into the reconstruction. RoD is able to provide additional low-contrast details while correctly incorporating actual physical changes in patient anatomy. Conclusions: The proposed framework provides an opportunity to either improve image quality or relax data fidelity constraints for CBCT imaging when prior CT studies of the same patient are available. Possible clinical targets include CBCT image-guided radiotherapy and CBCT image-guided surgeries.
Stereolithographic Surgical Template: A Review
Dandekeri, Shilpa Sudesh; Sowmya, M.K.; Bhandary, Shruthi
2013-01-01
Implant placement has become a routine modality of dental care.Improvements in surgical reconstructive methods as well as increased prosthetic demands,require a highly accurate diagnosis, planning and placement. Recently,computer-aided design and manufacturing have made it possible to use data from computerised tomography to not only plan implant rehabilitation,but also transfer this information to the surgery.A review on one of this technique called Stereolithography is presented in this article.It permits graphic and complex 3D implant placement and fabrication of stereolithographic surgical templates. Also offers many significant benefits over traditional procedures. PMID:24179955
Putman, Melissa S; Yu, Elaine W; Lin, David; Darakananda, Karin; Finkelstein, Joel S; Bouxsein, Mary L
2017-01-01
Black women have lower fracture risk compared with white women, which may be partly explained by improved volumetric bone mineral density (vBMD) and bone microarchitecture primarily within the cortical bone compartment. To determine if there are differences in trabecular microstructure, connectivity, and alignment according to race/ethnicity, we performed individual trabecular segmentation (ITS) analyses on high-resolution peripheral quantitative computed tomography (HR-pQCT) scans of the distal radius and tibia in 273 peri- and postmenopausal black (n = 100) and white (n = 173) women participating in the Study of Women’s Health Across the Nation in Boston. Unadjusted analyses showed that black women had greater trabecular plate volume fraction, plate thickness, plate number density, and plate surface area along with greater axial alignment of trabeculae, whereas white women had greater trabecular rod tissue fraction (p < 0.05 for all). Adjustment for clinical covariates augmented these race/ethnicity-related differences in plates and rods, such that white women had greater trabecular rod number density and rod-rod connectivity, whereas black women continued to have superior plate structural characteristics and axial alignment (p < 0.05 for all). These differences remained significant after adjustment for hip BMD and trabecular vBMD. In conclusion, black women had more plate-like trabecular morphology and higher axial alignment of trabeculae, whereas white women had more rod-like trabeculae. These differences may contribute to the improved bone strength and lower fracture risk observed in black women. PMID:27958659
Higher order parametric excitation modes for spaceborne quadrupole mass spectrometers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gershman, D. J.; Block, B. P.; Rubin, M.
This paper describes a technique to significantly improve upon the mass peak shape and mass resolution of spaceborne quadrupole mass spectrometers (QMSs) through higher order auxiliary excitation of the quadrupole field. Using a novel multiresonant tank circuit, additional frequency components can be used to drive modulating voltages on the quadrupole rods in a practical manner, suitable for both improved commercial applications and spaceflight instruments. Auxiliary excitation at frequencies near twice that of the fundamental quadrupole RF frequency provides the advantages of previously studied parametric excitation techniques, but with the added benefit of increased sensed excitation amplitude dynamic range and themore » ability to operate voltage scan lines through the center of upper stability islands. Using a field programmable gate array, the amplitudes and frequencies of all QMS signals are digitally generated and managed, providing a robust and stable voltage control system. These techniques are experimentally verified through an interface with a commercial Pfeiffer QMG422 quadrupole rod system. When operating through the center of a stability island formed from higher order auxiliary excitation, approximately 50% and 400% improvements in 1% mass resolution and peak stability were measured, respectively, when compared with traditional QMS operation. Although tested with a circular rod system, the presented techniques have the potential to improve the performance of both circular and hyperbolic rod geometry QMS sensors.« less
Tamoxifen and vitamin E treatments delay symptoms in the mouse model of Niemann-Pick C.
Bascuñan-Castillo, Eric C; Erickson, Robert P; Howison, Christy M; Hunter, Robert J; Heidenreich, Randall H; Hicks, Chad; Trouard, Theodore P; Gillies, Robert J
2004-01-01
Niemann-Pick C disease (NPC) is an irreversible neurodegenerative disorder without current treatment. It is the result of deficient intracellular cholesterol movement. We investigated the effects of tamoxifen and vitamin E (D-alpha tocopherol) treatment on patterns of weight loss and motor function in the mouse model of Niemann-Pick C disease (Npc1-/- mice). Tamoxifen has multiple metabolic effects, including reducing oxidative damage, while vitamin E primarily has this property. Npc1-/- mice were identified and treatment was initiated at an approximate age of 21 days. Tamoxifen suspended in peanut oil was administered via intraperitoneal injection (weekly, at a dose calculated to deliver 0.023 microg/g/day). Vitamin E (25 IU) was administered orally via gavage once a week. Weight loss and Rota-Rod performance were analyzed by using Kaplan-Meyer survival curves. Tamoxifen treatment by itself significantly delayed weight loss (an endpoint of neurodegeneration) in male and female mice compared to untreated controls. Motor function was evaluated by performance on a Rota-Rod. Tamoxifen maintained Rota-Rod performance for about an extra week. Vitamin E treatment significantly delayed weight loss in females only. Rota-Rod performance was maintained slightly longer in mice treated with vitamin E. Simultaneous use of both treatments did not delay weight loss longer than tamoxifen-only treatment but had a greater effect than either treatment alone on Rota-Rod performance and demonstrated a significant positive effect on the early "learning curve" portion of the Rota-Rod evaluations. We found significant but relatively small improvements in rate of disease progression by treating Npc1-/- mice with tamoxifen and/or vitamin E. Some sex differences in response and an early improvement in Rota-Rod performance suggest areas for further study.
Bright flash response recovery of mammalian rods in vivo is rate limited by RGS9
Peinado Allina, Gabriel; Fortenbach, Christopher; Gross, Owen P.; Pugh, Edward N.
2017-01-01
The temporal resolution of scotopic vision is thought to be constrained by the signaling kinetics of retinal rods, which use a highly amplified G-protein cascade to transduce absorbed photons into changes in membrane potential. Much is known about the biochemical mechanisms that determine the kinetics of rod responses ex vivo, but the rate-limiting mechanisms in vivo are unknown. Using paired flash electroretinograms with improved signal-to-noise, we have recorded the amplitude and kinetics of rod responses to a wide range of flash strengths from living mice. Bright rod responses in vivo recovered nearly twice as fast as all previous recordings, although the kinetic consequences of genetic perturbations previously studied ex vivo were qualitatively similar. In vivo, the dominant time constant of recovery from bright flashes was dramatically reduced by overexpression of the RGS9 complex, revealing G-protein deactivation to be rate limiting for recovery. However, unlike previous ex vivo recordings, dim flash responses in vivo were relatively unaffected by RGS9 overexpression, suggesting that other mechanisms, such as calcium feedback dynamics that are strongly regulated by the restricted subretinal microenvironment, act to determine rod dim flash kinetics. To assess the consequences for scotopic vision, we used a nocturnal wheel-running assay to measure the ability of wild-type and RGS9-overexpressing mice to detect dim flickering stimuli and found no improvement when rod recovery was speeded by RGS9 overexpression. These results are important for understanding retinal circuitry, in particular as modeled in the large literature that addresses the relationship between the kinetics and sensitivity of retinal responses and visual perception. PMID:28302678
DOE Office of Scientific and Technical Information (OSTI.GOV)
Connor, Michael J.; University of California Irvine School of Medicine, Irvine, California; Tringale, Kathryn
Purpose: To analyze all recalls involving radiation oncology devices (RODs) from the US Food and Drug Administration (FDA)'s recall database, comparing these with non–radiation oncology device recalls to identify discipline-specific trends that may inform improvements in device safety. Methods and Materials: Recall data on RODs from 2002 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems). Outcomes included determined cause of recall, recall class (severity), quantity in commerce, time until recall termination (date FDA determines recall is complete), and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Resultsmore » for RODs were compared with those for other devices by Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 502 ROD recalls and 9534 other class II device recalls during 2002 to 2015. Most recalls were for external beam devices (66.7%) and planning systems (22.9%), and recall events peaked in 2011. Radiation oncology devices differed significantly from other devices in all recall outcomes (P≤.04). Recall cause was commonly software related (49% vs 10% for other devices). Recall severity was more often moderate among RODs (97.6% vs 87.2%) instead of severe (0.2% vs 4.4%; P<.001). Time from 510(k) market approval to recall was shorter among RODs (P<.001) and progressively shortened over time. Radiation oncology devices had fewer recalled devices in commerce than other devices (P<.001). Conclusions: Compared with other class II devices, RODs experience recalls sooner after market approval and are trending sooner still. Most of these recalls were moderate in severity, and software issues are prevalent. Comprehensive analysis of recall data can identify areas for device improvement, such as better system design among RODs.« less
Soil sampling device with latch assembly having a variable circumferential shape
Meyer, R.D.
1996-12-24
The invention relates to an improved sampler which can be operated in any orientation. The design features a positive gripping of the operating rod in a manner to reduce point loads so as to reduce any possibility of jamming of the rod on a retraction stroke until such time as it is positively retained in the fully withdrawn position. In the preferred embodiment, a pair of mating cylindrical latch pieces, held together by a circumferential spring, are used for positive actuation. The inner rod has an angular cut-out which provides the base for the latch when aligned with the latch. A release fixture can be used to free the latch from the cone rod after actuation. The latches are formed in such a manner as they may support themselves within the housing of the sampler until they engage the operating rod. 11 figs.
Soil sampling device with latch assembly having a variable circumferential shape
Meyer, Robert D.
1996-01-01
The invention relates to an improved sampler which can be operated in any orientation. The design features a positive gripping of the operating rod in a manner to reduce point loads so as to reduce any possibility of jamming of the rod on a retraction stroke until such time as it is positively retained in the fully withdrawn position. In the preferred embodiment, a pair of mating cylindrical latch pieces, held together by a circumferential spring, are used for positive actuation. The inner rod has an angular cut-out which provides the base for the latch when aligned with the latch. A release fixture can be used to free the latch from the cone rod after actuation. The latches are formed in such a manner as they may support themselves within the housing of the sampler until they engage the operating rod.
Wavelength-selective thermal emitters using Si-rods on MgO
NASA Astrophysics Data System (ADS)
Suemitsu, Masahiro; Asano, Takashi; De Zoysa, Menaka; Noda, Susumu
2018-01-01
Supporting substrates for Si rod-type photonic crystals (PCs) are investigated for realizing highly wavelength-selective near-infrared thermal emitters. Three materials—SiO2, Al2O3, and MgO—are considered for their low infrared emission (transparency) and remarkable heat resistance. Theoretical calculations of the emissivity spectra of Si-rod PCs (rod height = 500 nm, rod diameter = 300 nm, and lattice constant = 600 nm) on 50 μm-thick supporting substrates at 1400 K indicate that the long-wavelength (>3 μm) emission power from the emitter using MgO is less than 1/10 of that of the other two materials. Fabrication of the Si-rod PCs on the 50 μm-thick MgO substrate requires the insertion of a thin (30 nm) HfO2 film between MgO and Si to improve the stability at high temperatures (>1400 K). Experimental results of the fabricated structure show that at 1400 K, the ratio of emissive power at wavelengths <1.8 μm to the total emissive power is 34% and that this can be increased to over 53% in an optimized rod-array structure with a 10 μm-thick MgO substrate.
Johnston, D G; Hall, K; Kendall-Taylor, P; Patrick, D; Watson, M; Cook, D B
1984-07-28
The clinical, radiological, and biochemical effects of dopamine agonist withdrawal after long-term treatment were investigated in seven women and eight men who had been treated for prolactinomas for 1.5 to 7 (mean 3.7) years. Before treatment, serum prolactin concentrations were 1473 to 115 000 mU/l, all patients had abnormal radiological findings, and six had suprasellar extensions of pituitary tumours. Treatment with either bromocriptine or pergolide relieved symptoms and suppressed prolactin secretion in most patients. The size of the residual tumour was defined by doing fourth generation computerised tomographic scans immediately before termination of therapy, and evidence of tumour re-expansion was sought on scans repeated 5-39 weeks later. After discontinuation of treatment, symptoms recurred in 13 of 15 patients and hyper-prolactinaemia redeveloped in 14. Other pituitary function tests remained unchanged or improved. In 13 of 15 patients tumour or gland size did not change after withdrawal of treatment. One man had a marginal increase in tumour size, while in another the pituitary tumour shrank. Thus, although cessation of long-term dopamine agonist therapy leads to recurrence of symptoms and hyperprolactinaemia, rapid tumour regrowth is uncommon and of small extent, and other pituitary function is not altered in the short term.
Fernandez-Granero, Miguel Angel; Sanchez-Morillo, Daniel; Leon-Jimenez, Antonio
2015-10-23
Chronic obstructive pulmonary disease (COPD) is one of the commonest causes of death in the world and poses a substantial burden on healthcare systems and patients' quality of life. The largest component of the related healthcare costs is attributable to admissions due to acute exacerbation (AECOPD). The evidence that might support the effectiveness of the telemonitoring interventions in COPD is limited partially due to the lack of useful predictors for the early detection of AECOPD. Electronic stethoscopes and computerised analyses of respiratory sounds (CARS) techniques provide an opportunity for substantial improvement in the management of respiratory diseases. This exploratory study aimed to evaluate the feasibility of using: (a) a respiratory sensor embedded in a self-tailored housing for ageing users; (b) a telehealth framework; (c) CARS and (d) machine learning techniques for the remote early detection of the AECOPD. In a 6-month pilot study, 16 patients with COPD were equipped with a home base-station and a sensor to daily record their respiratory sounds. Principal component analysis (PCA) and a support vector machine (SVM) classifier was designed to predict AECOPD. 75.8% exacerbations were early detected with an average of 5 ± 1.9 days in advance at medical attention. The proposed method could provide support to patients, physicians and healthcare systems.
Fretting corrosion behavior of nitinol spinal rods in conjunction with titanium pedicle screws.
Lukina, Elena; Kollerov, Mikhail; Meswania, Jay; Khon, Alla; Panin, Pavel; Blunn, Gordon W
2017-03-01
Untypical corrosion damage including erosions combined with the build-up of titanium oxide as a corrosion product on the surface of explanted Nitinol spinal rods in the areas where it was in contact with titanium pedicle screw head is reported. It was suggested that Nitinol rods might have inferior fretting corrosion resistance compared with that made of titanium or CoCr. Fretting corrosion of Nitinol spinal rods with titanium (Ti6Al4V) pedicle screws were tested in-vitro by conducting a series of potentiostatic measurements of the peak-to-peak values of fretting corrosion current under bending in a 10% solution of calf serum in PBS. The test included Nitinol rods locked in titanium pedicle screws of different designs. Performance of commercially available titanium (Ti6Al4V) and CoCr spinal rods was also investigated for a comparison. Corrosion damage observed after the in-vitro tests was studied using SEM and EDAX analysis and was compared with patterns on Nitinol rods retrieved 12months after initial surgery. Metal ions level was measured in the test media after in-vitro experiments and in the blood and tissues of the patients who had the rods explanted. The results of this study revealed that Nitinol spinal rods locked in Ti pedicle screws are susceptible to fretting corrosion demonstrating higher fretting corrosion current compared with commercially used Ti6Al4V and CoCr rods. On the surface of Nitinol rods after in-vitro tests and on those retrieved from the patients similar corrosion patterns were observed. Improved resistance to fretting corrosion was observed with Nitinol rods in the in-vitro tests where pedicle screws were used with a stiffer locking mechanism. Since the development of the localized corrosion damage might increase the risk of premature fatigue failure of the rods and result in leaching of Ni ions, it is concluded that Nitinol rods should not be used in conjunction with Ti pedicle screws without special protection especially where the design provides a high degree of mobility to the rods. Copyright © 2016 Elsevier B.V. All rights reserved.
Chemical Dosimeter Tube With Coaxial Sensing Rod
NASA Technical Reports Server (NTRS)
Lueck, Dale E.
1993-01-01
Improved length-of-stain (LOS) chemical dosimeter indicates total dose of chemical vapor in air. Made with rods and tubes of various diameters to obtain various sensitivities and dynamic ranges. Sensitivity larger and dose range smaller when more room for diffusion in gap between tube and rod. Offers greater resistance to changing of color of exposed dye back to color of unexposed condition, greater sensitivity, and higher degree of repeatability. Developed to measure doses of gaseous HCI, dosimeter modified by use of other dyes to indicate doses of other chemical vapors.
Growth of copper phthalocyanine rods on Au plasmon electrodes through micelle disruption methods.
Chen, Wei-Hung; Ko, Wen-Yin; Chen, Ying-Shiou; Cheng, Ching-Yuan; Chan, Chi-Ming; Lin, Kuan-Jiuh
2010-02-16
To improve the efficiency of the photocurrent conversion process, we have utilized copper phthalocyanine (CuPc) rods, which are capable of enhancing the interfacial area of electron transport and plasmonic gold nanoparticles (Au NPs), which can increase the separation and photogeneration of excitons, to produce a more effective system. In-plane horizontal CuPc rods, with diameters ranging from 0.2 to 1.5 microm, were electrodeposited onto the surface of plasmonic (Au NP) monolayers predeposited onto ITO substrates through electrolytic micelle disruption (EMD) methods.
Solid expellant plasma generator
NASA Technical Reports Server (NTRS)
Stone, Nobie H. (Inventor); Poe, Garrett D. (Inventor); Rood, Robert (Inventor)
2010-01-01
An improved solid expellant plasma generator has been developed. The plasma generator includes a support housing, an electrode rod located in the central portion of the housing, and a mass of solid expellant material that surrounds the electrode rod within the support housing. The electrode rod and the solid expellant material are made of separate materials that are selected so that the electrode and the solid expellant material decompose at the same rate when the plasma generator is ignited. This maintains a point of discharge of the plasma at the interface between the electrode and the solid expellant material.
Head assembly for multiposition borehole extensometer
Frank, Donald N.
1983-01-01
A head assembly for a borehole extensometer and an improved extensometer for measuring subsurface subsidence. A plurality of inflatable anchors provide discrete measurement points. A metering rod is fixed to each of the anchors which are displaced when subsidence occurs, thereby translating the attached rod. The head assembly includes a sprocket wheel rotatably mounted on a standpipe and engaged by a chain which is connected at one end to the metering rod and at the other end to a counterweight. A second sprocket wheel connected to the standpipe also engages the chain and drives a connected potentiometer. The head assembly converts the linear displacement of the metering rod to the rotary motion of the second sprocket wheel, which is measured by the potentiometer, producing a continuous electrical output.
Alexander, David J.
1994-01-01
An attachment for placement between a test specimen and a remote clip gage extensometer providing improved fracture toughness tests of materials at elevated temperature. Using a cylindrical tube and axial rod in new relationship, the device transfers the displacement signal of the fracture toughness test specimen directly to a clip gage extensometer located outside the high temperature furnace. Virtually frictionless operation is assured by having the test specimen center one end of the rod in one end of the tube, while the clip gage extensometer arms center the other end of the rod in the other end of the tube. By providing positive control over both ends of both rod and tube, the attachment may be operated in orientations other than vertical.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brzoska, B.; Depisch, F.; Fuchs, H.P.
To analyze the influence of prepressurization on fuel rod behavior, a parametric study has been performed that considers the effects of as-fabricated fuel rod internal prepressure on the normal operation and postulated loss-of-coolant accident (LOCA) rod behavior of a 1300-MW(electric) Kraftwerk Union (KWU) standard pressurized water reactor nuclear power plant. A variation of the prepressure in the range from 15 to 35 bars has only a slight influence on normal operation behavior. Considering the LOCA behavior, only a small temperature increase results from prepressure reduction, while the core-wide straining behavior is improved significantly. The KWU prepressurization takes both conditions intomore » account.« less
Preliminary experience with SpineEOS, a new software for 3D planning in AIS surgery.
Ferrero, Emmanuelle; Mazda, Keyvan; Simon, Anne-Laure; Ilharreborde, Brice
2018-04-24
Preoperative planning of scoliosis surgery is essential in the effective treatment of spine pathology. Thus, precontoured rods have been recently developed to avoid iatrogenic sagittal misalignment and rod breakage. Some specific issues exist in adolescent idiopathic scoliosis (AIS), such as a less distal lower instrumented level, a great variability in the location of inflection point (transition from lumbar lordosis to thoracic kyphosis), and sagittal correction is limited by both bone-implant interface. Since 2007, stereoradiographic imaging system is used and allows for 3D reconstructions. Therefore, a software was developed to perform preoperative 3D surgical planning and to provide rod's shape and length. The goal of this preliminary study was to assess the feasibility, reliability, and the clinical relevance of this new software. Retrospective study on 47 AIS patients operated with the same surgical technique: posteromedial translation through posterior approach with lumbar screws and thoracic sublaminar bands. Pre- and postoperatively, 3D reconstructions were performed on stereoradiographic images (EOS system, Paris, France) and compared. Then, the software was used to plan the surgical correction and determine rod's shape and length. Simulated spine and rods were compared to postoperative real 3D reconstructions. 3D reconstructions and planning were performed by an independent observer. 3D simulations were performed on the 47 patients. No difference was found between the simulated model and the postoperative 3D reconstructions in terms of sagittal parameters. Postoperatively, 21% of LL were not within reference values. Postoperative SVA was 20 mm anterior in 2/3 of the cases. Postoperative rods were significantly longer than precontoured rods planned with the software (mean 10 mm). Inflection points were different on the rods used and the planned rods (2.3 levels on average). In this preliminary study, the software based on 3D stereoradiography low-dose system used to plan AIS surgery seems reliable for preoperative planning and precontoured rods. It is an interesting tool to improve surgeons' practice, since 3D planning is expected to reduce complications such as iatrogenic malalignment and to help for a better understanding of the complications, choosing the location of the transitional vertebra. However, further work is needed to improve thoracic kyphosis planning. These slides can be retrieved under Electronic Supplementary Material.
Large-eddy simulation, fuel rod vibration and grid-to-rod fretting in pressurized water reactors
Christon, Mark A.; Lu, Roger; Bakosi, Jozsef; ...
2016-10-01
Grid-to-rod fretting (GTRF) in pressurized water reactors is a flow-induced vibration phenomenon that results in wear and fretting of the cladding material on fuel rods. GTRF is responsible for over 70% of the fuel failures in pressurized water reactors in the United States. Predicting the GTRF wear and concomitant interval between failures is important because of the large costs associated with reactor shutdown and replacement of fuel rod assemblies. The GTRF-induced wear process involves turbulent flow, mechanical vibration, tribology, and time-varying irradiated material properties in complex fuel assembly geometries. This paper presents a new approach for predicting GTRF induced fuelmore » rod wear that uses high-resolution implicit large-eddy simulation to drive nonlinear transient dynamics computations. The GTRF fluid–structure problem is separated into the simulation of the turbulent flow field in the complex-geometry fuel-rod bundles using implicit large-eddy simulation, the calculation of statistics of the resulting fluctuating structural forces, and the nonlinear transient dynamics analysis of the fuel rod. Ultimately, the methods developed here, can be used, in conjunction with operational management, to improve reactor core designs in which fuel rod failures are minimized or potentially eliminated. Furthermore, robustness of the behavior of both the structural forces computed from the turbulent flow simulations and the results from the transient dynamics analyses highlight the progress made towards achieving a predictive simulation capability for the GTRF problem.« less
Large-eddy simulation, fuel rod vibration and grid-to-rod fretting in pressurized water reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christon, Mark A.; Lu, Roger; Bakosi, Jozsef
Grid-to-rod fretting (GTRF) in pressurized water reactors is a flow-induced vibration phenomenon that results in wear and fretting of the cladding material on fuel rods. GTRF is responsible for over 70% of the fuel failures in pressurized water reactors in the United States. Predicting the GTRF wear and concomitant interval between failures is important because of the large costs associated with reactor shutdown and replacement of fuel rod assemblies. The GTRF-induced wear process involves turbulent flow, mechanical vibration, tribology, and time-varying irradiated material properties in complex fuel assembly geometries. This paper presents a new approach for predicting GTRF induced fuelmore » rod wear that uses high-resolution implicit large-eddy simulation to drive nonlinear transient dynamics computations. The GTRF fluid–structure problem is separated into the simulation of the turbulent flow field in the complex-geometry fuel-rod bundles using implicit large-eddy simulation, the calculation of statistics of the resulting fluctuating structural forces, and the nonlinear transient dynamics analysis of the fuel rod. Ultimately, the methods developed here, can be used, in conjunction with operational management, to improve reactor core designs in which fuel rod failures are minimized or potentially eliminated. Furthermore, robustness of the behavior of both the structural forces computed from the turbulent flow simulations and the results from the transient dynamics analyses highlight the progress made towards achieving a predictive simulation capability for the GTRF problem.« less
Van de Velde, Stijn; Kunnamo, Ilkka; Roshanov, Pavel; Kortteisto, Tiina; Aertgeerts, Bert; Vandvik, Per Olav; Flottorp, Signe
2018-06-25
Computerised decision support (CDS) based on trustworthy clinical guidelines is a key component of a learning healthcare system. Research shows that the effectiveness of CDS is mixed. Multifaceted context, system, recommendation and implementation factors may potentially affect the success of CDS interventions. This paper describes the development of a checklist that is intended to support professionals to implement CDS successfully. We developed the checklist through an iterative process that involved a systematic review of evidence and frameworks, a synthesis of the success factors identified in the review, feedback from an international expert panel that evaluated the checklist in relation to a list of desirable framework attributes, consultations with patients and healthcare consumers and pilot testing of the checklist. We screened 5347 papers and selected 71 papers with relevant information on success factors for guideline-based CDS. From the selected papers, we developed a 16-factor checklist that is divided in four domains, i.e. the CDS context, content, system and implementation domains. The panel of experts evaluated the checklist positively as an instrument that could support people implementing guideline-based CDS across a wide range of settings globally. Patients and healthcare consumers identified guideline-based CDS as an important quality improvement intervention and perceived the GUIDES checklist as a suitable and useful strategy. The GUIDES checklist can support professionals in considering the factors that affect the success of CDS interventions. It may facilitate a deeper and more accurate understanding of the factors shaping CDS effectiveness. Relying on a structured approach may prevent that important factors are missed.
Control rod calibration and reactivity effects at the IPEN/MB-01 reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pinto, Letícia Negrão; Gonnelli, Eduardo; Santos, Adimir dos
2014-11-11
Researches that aim to improve the performance of neutron transport codes and quality of nuclear cross section databases are very important to increase the accuracy of simulations and the quality of the analysis and prediction of phenomena in the nuclear field. In this context, relevant experimental data such as reactivity worth measurements are needed. Control rods may be made of several neutron absorbing materials that are used to adjust the reactivity of the core. For the reactor operation, these experimental data are also extremely important: with them it is possible to estimate the reactivity worth by the movement of themore » control rod, understand the reactor response at each rod position and to operate the reactor safely. This work presents a temperature correction approach for the control rod calibration problem. It is shown the control rod calibration data of the IPEN/MB-01 reactor, the integral and differential reactivity curves and a theoretical analysis, performed by the MCNP-5 reactor physics code, developed and maintained by Los Alamos National Laboratory, using the ENDF/B-VII.0 nuclear data library.« less
NASA Astrophysics Data System (ADS)
Ozabaci, M.; Rasekh, Sh.; Kizilaslan, O.; Madre, M. A.; Sotelo, A.; Yakinci, M. E.
2015-01-01
Fe-substituted superconducting thin BiSrCaCuO rods with nominal compositions of Bi2Sr2Ca1Cu2- x Fe x O8+ δ ( x = 0, 0.01, 0.03, 0.05, and 0.1) were fabricated using the laser floating zone technique at two different growth speeds, 15 mm h-1 and 30 mm h-1. The influences of growth speed and Fe substitution on the grain alignment in the rods were evaluated by means of x-ray pole figure studies. The obtained results showed that both applied growth speed and Fe substitution play a crucial role on grain alignment, which is strongly connected with the current-carrying capacity of the rods. It was found that the rods grown at 15 mm h-1 (G15) have stronger orientation than the rods grown at 30 mm h-1 (G30). However, in contrast to the G15 rods, an increased substitution rate improved the orientation of the G30 rods. Another important observation is that the increase on the substitution caused a decrease on the grain size of all the rods. The decrease of critical temperature values of the rods upon substitution was ascribed to both grain size effect and formation of a nonsuperconducting Fe-rich phase detected in scanning electron microscope/energy-dispersive x-ray analyses. The thermal conductivity values of the G15 and G30 rods were found to be in the range of 0.9-1.9 and 1.1-1.18 W m-1 K-1 at 150 K, respectively. The higher values of figure of merit ( ZT), at all temperature ranges, were obtained from the highest substituted rods ( x = 0.1) for both of the applied growth speeds. In addition, it was observed that the ZT of G30 rods are up to three times higher than that of G15 ones.
Successful gene therapy in the RPGRIP1-deficient dog: a large model of cone-rod dystrophy.
Lhériteau, Elsa; Petit, Lolita; Weber, Michel; Le Meur, Guylène; Deschamps, Jack-Yves; Libeau, Lyse; Mendes-Madeira, Alexandra; Guihal, Caroline; François, Achille; Guyon, Richard; Provost, Nathalie; Lemoine, Françoise; Papal, Samantha; El-Amraoui, Aziz; Colle, Marie-Anne; Moullier, Philippe; Rolling, Fabienne
2014-02-01
For the development of new therapies, proof-of-concept studies in large animal models that share clinical features with their human counterparts represent a pivotal step. For inherited retinal dystrophies primarily involving photoreceptor cells, the efficacy of gene therapy has been demonstrated in canine models of stationary cone dystrophies and progressive rod-cone dystrophies but not in large models of progressive cone-rod dystrophies, another important cause of blindness. To address the last issue, we evaluated gene therapy in the retinitis pigmentosa GTPase regulator interacting protein 1 (RPGRIP1)-deficient dog, a model exhibiting a severe cone-rod dystrophy similar to that seen in humans. Subretinal injection of AAV5 (n = 5) or AAV8 (n = 2) encoding the canine Rpgrip1 improved photoreceptor survival in transduced areas of treated retinas. Cone function was significantly and stably rescued in all treated eyes (18-72% of those recorded in normal eyes) up to 24 months postinjection. Rod function was also preserved (22-29% of baseline function) in four of the five treated dogs up to 24 months postinjection. No detectable rod function remained in untreated contralateral eyes. More importantly, treatment preserved bright- and dim-light vision. Efficacy of gene therapy in this large animal model of cone-rod dystrophy provides great promise for human treatment.
Defect reduction in overgrown semi-polar (11-22) GaN on a regularly arrayed micro-rod array template
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Y.; Bai, J.; Hou, Y.
2016-02-15
We demonstrate a great improvement in the crystal quality of our semi-polar (11-22) GaN overgrown on regularly arrayed micro-rod templates fabricated using a combination of industry-matched photolithography and dry-etching techniques. As a result of our micro-rod configuration specially designed, an intrinsic issue on the anisotropic growth rate which is a great challenge in conventional overgrowth technique for semi-polar GaN has been resolved. Transmission electron microscopy measurements show a different mechanism of defect reduction from conventional overgrowth techniques and also demonstrate major advantages of our approach. The dislocations existing in the GaN micro-rods are effectively blocked by both a SiO{sub 2}more » mask on the top of each GaN micro-rod and lateral growth along the c-direction, where the growth rate along the c-direction is faster than that along any other direction. Basal stacking faults (BSFs) are also effectively impeded, leading to a distribution of BSF-free regions periodically spaced by BSF regions along the [-1-123] direction, in which high and low BSF density areas further show a periodic distribution along the [1-100] direction. Furthermore, a defect reduction model is proposed for further improvement in the crystalline quality of overgrown (11-22) GaN on sapphire.« less
Rasch-built Overall Disability Scale for Multifocal motor neuropathy (MMN-RODS(©) ).
Vanhoutte, Els K; Faber, Catharina G; van Nes, Sonja I; Cats, Elisabeth A; Van der Pol, W-Ludo; Gorson, Kenneth C; van Doorn, Pieter A; Cornblath, David R; van den Berg, Leonard H; Merkies, Ingemar S J
2015-09-01
Clinical trials in multifocal motor neuropathy (MMN) have often used ordinal-based measures that may not accurately capture changes. We aimed to construct a disability interval outcome measure specifically for MMN using the Rasch model and to examine its clinimetric properties. A total of 146 preliminary activity and participation items were assessed twice (reliability studies) in 96 clinically stable MMN patients. These patients also assessed the ordinal-based overall disability sum score (construct, sample-dependent validity). The final Rasch-built overall disability scale for MMN (MMN-RODS(©) ) was serially applied in 26 patients with newly diagnosed or relapsing MMN, treated with intravenous immunoglobulin (IVIg) (1-year follow-up; responsiveness study). The magnitude of change for each patient was calculated using the minimum clinically important difference technique related to the individually obtained standard errors. A total of 121 items not fulfilling Rasch requirements were removed. The final 25-item MMN-RODS(©) fulfilled all Rasch model's expectations and showed acceptable reliability and validity including good discriminatory capacity. Most serially examined patients improved, but its magnitude was low, reflecting poor responsiveness. The constructed MMN-RODS(©) is a disease-specific, interval measure to detect activity limitations in patients with MMN and overcomes the shortcomings of ordinal scales. However, future clinimetric studies are needed to improve the MMN-RODS(©) 's responsiveness by longer observations and/or more rigorous treatment regimens. © 2015 Peripheral Nerve Society.
Relief of Residual Stress in Streamline Tie Rods by Heat Treatment
NASA Technical Reports Server (NTRS)
Pollard, R E; Reinhart, Fred M
1941-01-01
About two-thirds of the residual stress in cold-worked SAE 1050 steel tie rods was relieved by heating 30 minutes at 600 degrees Fahrenheit. Cold-worked austenitic stainless-steel tie rods could be heated at temperatures up to 1000 degrees Fahrenheit without lowering the important physical properties. The corrosion resistance, in laboratory corrosion test, of straight 18:8 and titanium-treated 18:8 materials appeared to be impaired after heating at temperatures above 800 degrees or 900 degrees fahrenheit. Columbium-treated and molybdenum-treated 18:8 steel exhibited improved stability over a wide range of temperatures. Tie rods of either material could be heated 30 minutes with safety at any temperature up to 1000 degrees Fahrenheit. At this temperature most of the residual stress would be relieved.
Alexander, D.J.
1994-01-04
An attachment for placement between a test specimen and a remote clip gage extensometer providing improved fracture toughness tests of materials at elevated temperature is described. Using a cylindrical tube and axial rod in new relationship, the device transfers the displacement signal of the fracture toughness test specimen directly to a clip gage extensometer located outside the high temperature furnace. Virtually frictionless operation is assured by having the test specimen center one end of the rod in one end of the tube, while the clip gage extensometer arms center the other end of the rod in the other end of the tube. By providing positive control over both ends of both rod and tube, the attachment may be operated in orientations other than vertical. 1 figure.
Blignaut, P J; McDonald, T; Tolmie, C J
2001-05-01
A prototyping approach was used to determine the essential system requirements of a computerised patient record information system for a typical township primary health care clinic. A pilot clinic was identified and the existing manual system and business processes in this clinic was studied intensively before the first prototype was implemented. Interviews with users, incidental observations and analysis of actual data entered were used as primary techniques to refine the prototype system iteratively until a system with an acceptable data set and adequate functionalities were in place. Several non-functional and user-related requirements were also discovered during the prototyping period.
The effect of maternal methadone use on the fetal heart pattern: a computerised CTG analysis.
Navaneethakrishnan, R; Tutty, S; Sinha, C; Lindow, S W
2006-08-01
Using a computerised analysis, the cardiotocograph (CTG) from women who use methadone (n= 25) when compared with women who do not use methadone (n= 25) showed a significant reduction in the fetal heart baseline rate, with a significant reduction in number of accelerations and episodes of high variation. The short-term variation, number of decelerations and episodes of low variation were not different between the two groups. The time taken to meet the standardised criteria was not different, and it is possible that a computer-assisted CTG analysis could be more accurate than a naked eye interpretation.
Low-cost printing of computerised tomography (CT) images where there is no dedicated CT camera.
Tabari, Abdulkadir M
2007-01-01
Many developing countries still rely on conventional hard copy images to transfer information among physicians. We have developed a low-cost alternative method of printing computerised tomography (CT) scan images where there is no dedicated camera. A digital camera is used to photograph images from the CT scan screen monitor. The images are then transferred to a PC via a USB port, before being printed on glossy paper using an inkjet printer. The method can be applied to other imaging modalities like ultrasound and MRI and appears worthy of emulation elsewhere in the developing world where resources and technical expertise are scarce.
Computerised analysis of facial emotion expression in eating disorders.
Leppanen, Jenni; Dapelo, Marcela Marin; Davies, Helen; Lang, Katie; Treasure, Janet; Tchanturia, Kate
2017-01-01
Problems with social-emotional processing are known to be an important contributor to the development and maintenance of eating disorders (EDs). Diminished facial communication of emotion has been frequently reported in individuals with anorexia nervosa (AN). Less is known about facial expressivity in bulimia nervosa (BN) and in people who have recovered from AN (RecAN). This study aimed to pilot the use of computerised facial expression analysis software to investigate emotion expression across the ED spectrum and recovery in a large sample of participants. 297 participants with AN, BN, RecAN, and healthy controls were recruited. Participants watched film clips designed to elicit happy or sad emotions, and facial expressions were then analysed using FaceReader. The finding mirrored those from previous work showing that healthy control and RecAN participants expressed significantly more positive emotions during the positive clip compared to the AN group. There were no differences in emotion expression during the sad film clip. These findings support the use of computerised methods to analyse emotion expression in EDs. The findings also demonstrate that reduced positive emotion expression is likely to be associated with the acute stage of AN illness, with individuals with BN showing an intermediate profile.
Glaister, Karen
2005-09-01
The ability of nurses to perform accurate drug dosage calculations has repercussions for patients' well-being. How best to assist nurses develop competency in this area is paramount. This paper presents findings of a study conducted with undergraduate nurses to determine the effect of three instructional approaches on the learning of this skill. The quasi-experimental study exposed participants to one of three instructional approaches: integrative learning, computerised learning and a combination of integrative and computerised learning. Quantitative and qualitative approaches were used to explore differences in the instructional approaches and gain further understanding of the learning process. There was no statistical difference between the three instructional approaches on knowledge acquisition and transfer measures, other than measures for procedural knowledge, which was significant (F(2,47) = 3.33 at p < .044). A least-significant difference post hoc test (alpha = 0. 10) indicated computerised learning was significantly more effective in developing procedural knowledge. The provision of instructional strategies, which facilitate development of conditional knowledge and automaticity, is necessary for competency development in dosage calculations. Furthermore, the curriculum must incorporate authentic tasks and permit time to support competency attainment.
Assessment of existing Sierra/Fuego capabilities related to grid-to-rod-fretting (GTRF).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turner, Daniel Zack; Rodriguez, Salvador B.
2011-06-01
The following report presents an assessment of existing capabilities in Sierra/Fuego applied to modeling several aspects of grid-to-rod-fretting (GTRF) including: fluid dynamics, heat transfer, and fluid-structure interaction. We compare the results of a number of Fuego simulations with relevant sources in the literature to evaluate the accuracy, efficiency, and robustness of using Fuego to model the aforementioned aspects. Comparisons between flow domains that include the full fuel rod length vs. a subsection of the domain near the spacer show that tremendous efficiency gains can be obtained by truncating the domain without loss of accuracy. Thermal analysis reveals the extent tomore » which heat transfer from the fuel rods to the coolant is improved by the swirling flow created by the mixing vanes. Lastly, coupled fluid-structure interaction analysis shows that the vibrational modes of the fuel rods filter out high frequency turbulent pressure fluctuations. In general, these results allude to interesting phenomena for which further investigation could be quite fruitful.« less
NASA Astrophysics Data System (ADS)
Chen, Cheng; Jin, Dakai; Liu, Yinxiao; Wehrli, Felix W.; Chang, Gregory; Snyder, Peter J.; Regatte, Ravinder R.; Saha, Punam K.
2016-09-01
Osteoporosis is associated with increased risk of fractures, which is clinically defined by low bone mineral density. Increasing evidence suggests that trabecular bone (TB) micro-architecture is an important determinant of bone strength and fracture risk. We present an improved volumetric topological analysis algorithm based on fuzzy skeletonization, results of its application on in vivo MR imaging, and compare its performance with digital topological analysis. The new VTA method eliminates data loss in the binarization step and yields accurate and robust measures of local plate-width for individual trabeculae, which allows classification of TB structures on the continuum between perfect plates and rods. The repeat-scan reproducibility of the method was evaluated on in vivo MRI of distal femur and distal radius, and high intra-class correlation coefficients between 0.93 and 0.97 were observed. The method’s ability to detect treatment effects on TB micro-architecture was examined in a 2 years testosterone study on hypogonadal men. It was observed from experimental results that average plate-width and plate-to-rod ratio significantly improved after 6 months and the improvement was found to continue at 12 and 24 months. The bone density of plate-like trabeculae was found to increase by 6.5% (p = 0.06), 7.2% (p = 0.07) and 16.2% (p = 0.003) at 6, 12, 24 months, respectively. While the density of rod-like trabeculae did not change significantly, even at 24 months. A comparative study showed that VTA has enhanced ability to detect treatment effects in TB micro-architecture as compared to conventional method of digital topological analysis for plate/rod characterization in terms of both percent change and effect-size.
Fast reactor core concepts to improve transmutation efficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fujimura, Koji; Kawashima, Katsuyuki; Itooka, Satoshi
Fast Reactor (FR) core concepts to improve transmutation efficiency were conducted. A heterogeneous MA loaded core was designed based on the 1000MWe-ABR breakeven core. The heterogeneous MA loaded core with Zr-H loaded moderated targets had a better transmutation performance than the MA homogeneous loaded core. The annular pellet rod design was proposed as one of the possible design options for the MA target. It was shown that using annular pellet MA rods mitigates the self-shielding effect in the moderated target so as to enhance the transmutation rate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siefken, L.J.
1999-01-01
Models were designed to resolve deficiencies in the SCDAP/RELAP5/MOD3.2 calculations of the configuration and integrity of hot, partially oxidized cladding. These models are expected to improve the calculations of several important aspects of fuel rod behavior. First, an improved mapping was established from a compilation of PIE results from severe fuel damage tests of the configuration of melted metallic cladding that is retained by an oxide layer. The improved mapping accounts for the relocation of melted cladding in the circumferential direction. Then, rules based on PIE results were established for calculating the effect of cladding that has relocated from abovemore » on the oxidation and integrity of the lower intact cladding upon which it solidifies. Next, three different methods were identified for calculating the extent of dissolution of the oxidic part of the cladding due to its contact with the metallic part. The extent of dissolution effects the stress and thus the integrity of the oxidic part of the cladding. Then, an empirical equation was presented for calculating the stress in the oxidic part of the cladding and evaluating its integrity based on this calculated stress. This empirical equation replaces the current criterion for loss of integrity which is based on temperature and extent of oxidation. Finally, a new rule based on theoretical and experimental results was established for identifying the regions of a fuel rod with oxidation of both the inside and outside surfaces of the cladding. The implementation of these models is expected to eliminate the tendency of the SCDAP/RELAP5 code to overpredict the extent of oxidation of the upper part of fuel rods and to underpredict the extent of oxidation of the lower part of fuel rods and the part with a high concentration of relocated material. This report is a revision and reissue of the report entitled, Improvements in Modeling of Cladding Oxidation and Meltdown.« less
NASA Astrophysics Data System (ADS)
Miura, S.; Yoshida, Y.; Ichino, Y.; Xu, Q.; Matsumoto, K.; Ichinose, A.; Awaji, S.
2016-01-01
For use in high-magnetic-field coil-based applications, the critical current density (Jc) of REBa2Cu3Oy (REBCO, where RE = rare earth) coated conductors must be isotropically improved, with respect to the direction of the magnetic field; these improvements must be realized at the operating conditions of these applications. In this study, improvement of the Jc for various applied directions of magnetic field was achieved by controlling the morphology of the BaHfO3 (BHO) nano-rods in a SmBCO film. We fabricated the 3.0 vol. % BHO-doped SmBCO film at a low growth temperature of 720 °C, by using a seed layer technique (Ts = 720 °C film). The low-temperature growth resulted in a morphological change in the BHO nano-rods. In fact, a high number density of (3.1 ± 0.1) × 103 μm-2 of small (diameter: 4 ± 1 nm), discontinuous nano-rods that grew in various directions, was obtained. In Jc measurements, the Jc of the Ts = 720 °C film in all directions of the applied magnetic field was higher than that of the non-doped SmBCO film. The Jcmin (6.4 MA/cm2) of the former was more than 6 times higher than that (1.0 MA/cm2) of the latter at 40 K, under 3 T. The aforementioned results indicated that the discontinuous BHO nano-rods, which occurred with a high number density, exerted a 3D-like flux pinning at the measurement conditions considered. Moreover, at 4.2 K and under 17 T, a flux pinning force density of 1.6 TN/m3 was realized; this value was comparable to the highest value recorded, to date.
Butt, Muhammad Shoaib; Bai, Jing; Wan, Xiaofeng; Chu, Chenglin; Xue, Feng; Ding, Hongyan; Zhou, Guanghong
2017-01-01
Full biodegradable magnesium alloy (AZ31) strengthened poly-lactic acid (PLA) composite rods for potential application for bone fracture fixation were prepared by plastic injection process in this work. Their surface/interfacial morphologies, mechanical properties and vitro degradation were studied. In comparison with untreated Mg rod, porous MgO ceramic coating on Mg surface formed by Anodizing (AO) and micro-arc-oxidation (MAO)treatment can significantly improve the interfacial binding between outer PLA cladding and inner Mg rod due to the micro-anchoring action, leading to better mechanical properties and degradation performance of the composite rods.With prolonging immersion time in simulated body fluid (SBF) solution until 8weeks, the MgO porous coating were corroded gradually, along with the disappearance of original pores and the formation of a relatively smooth surface. This resulted in a rapidly reduction in mechanical properties for corresponding composite rods owing to the weakening of interfacial binding capacity. The present results indicated that this new PLA-clad Mg composite rods show good potential biomedical applications for implants and instruments of orthopedic inner fixation. Copyright © 2016 Elsevier B.V. All rights reserved.
Kim, Youngjo; Lam, Nguyen Dinh; Kim, Kangho; Kim, Sangin; Rotermund, Fabian; Lim, Hanjo; Lee, Jaejin
2012-07-01
Single-junction GaAs solar cell structures were grown by low-pressure MOCVD on GaAs (100) substrates. Micro-rod arrays with diameters of 2 microm, 5 microm, and 10 microm were fabricated on the surfaces of the GaAs solar cells via photolithography and wet chemical etching. The patterned surfaces were coated with Au nanoparticles using an Au colloidal solution. Characteristics of the GaAs solar cells with and without the micro-rod arrays and Au nanoparticles were investigated. The short-circuit current density of the GaAs solar cell with 2 microm rod arrays and Au nanoparticles increased up to 34.9% compared to that of the reference cell without micro-rod arrays and Au nanoparticles. The conversion efficiency of the GaAs solar cell that was coated with Au nanoparticles on the patterned surface with micro-rod arrays can be improved from 14.1% to 19.9% under 1 sun AM 1.5G illumination. These results show that micro-rod arrays and Au nanoparticle coating can be applied together in surface patterning to achieve a novel cost-effective anti-reflection technology.
Thresholds and noise limitations of colour vision in dim light.
Kelber, Almut; Yovanovich, Carola; Olsson, Peter
2017-04-05
Colour discrimination is based on opponent photoreceptor interactions, and limited by receptor noise. In dim light, photon shot noise impairs colour vision, and in vertebrates, the absolute threshold of colour vision is set by dark noise in cones. Nocturnal insects (e.g. moths and nocturnal bees) and vertebrates lacking rods (geckos) have adaptations to reduce receptor noise and use chromatic vision even in very dim light. In contrast, vertebrates with duplex retinae use colour-blind rod vision when noisy cone signals become unreliable, and their transition from cone- to rod-based vision is marked by the Purkinje shift. Rod-cone interactions have not been shown to improve colour vision in dim light, but may contribute to colour vision in mesopic light intensities. Frogs and toads that have two types of rods use opponent signals from these rods to control phototaxis even at their visual threshold. However, for tasks such as prey or mate choice, their colour discrimination abilities fail at brighter light intensities, similar to other vertebrates, probably limited by the dark noise in cones.This article is part of the themed issue 'Vision in dim light'. © 2017 The Author(s).
Song, Bo; Wang, Chunpeng; Guo, Ning; Pan, Hucheng; Xin, Renlong
2017-01-01
In this study, AZ91 magnesium alloy rods were used to investigate the effects of torsion deformation on microstructure and subsequent aging behavior. Extruded AZ91 rod has a uniform microstructure and typical fiber texture. Torsion deformation can generate a gradient microstructure on the cross-section of the rod. After torsion, from the center to the edge in the cross-section of the rod, both stored dislocations and area fraction of {10-12} twins gradually increase, and the basal pole of the texture tends to rotate in the ED direction. Direct aging usually generates coarse discontinuous precipitates and fine continuous precipitates simultaneously. Both twin structures and dislocations via torsion deformation can be effective microstructures for the nucleation of continuous precipitates during subsequent aging. Thus, aging after torsion can promote continuous precipitation and generate gradient precipitation characteristics. Both aging treatment and torsion deformation can reduce yield asymmetry, and torsion deformation enhances the aging hardening effect by promoting continuous precipitation. Therefore, combined use of torsion deformation and aging treatment can effectively enhance the yield strength and almost eliminate the yield asymmetry of the present extruded AZ91 rod. Finally, the relevant mechanisms are discussed. PMID:28772638
Design of cladding rods-assisted depressed-core few-mode fibers with improved modal spacing
NASA Astrophysics Data System (ADS)
Han, Jiawei; Zhang, Jie
2018-03-01
This paper investigates the design details of cladding rods-assisted (CRA) depressed-core (DC) few-mode fibers (FMFs) that feature more equally spaced linearly polarized (LP) modal effective indices, suitable for high-spatial-density weakly-coupled mode-division multiplexing systems. The influences of the index profile of cladding rods on LP mode-resolved effective index, bending sensitivity, and effective area Aeff, are numerically described. Based on the design considerations of LP modal Aeff-dependent spatial efficiency and LP modal bending loss-dependent robustness, the small LP21-LP02 and LP22-LP03 modal spacing limitations, encountered in state-of-the-art weakly-coupled step-index FMFs, have been substantially improved by at least 25%. In addition, the proposed CRA DC FMFs also show sufficiently large effective areas (in excess of 110 μm2) for all guided LP modes, which are expected to exhibit good nonlinear performance.
2015-01-01
Background Surgical treatments for early onset scoliosis (EOS), including growing rod constructs, involve many complications. Some are due to biomechanical factors. A construct that is more flexible than current instrumentation systems may reduce complications. The purpose of this preliminary study was to determine spine range of motion (ROM) after implantation of simulated growing rod constructs with a range of clinically relevant structural properties. The hypothesis was that ROM of spines instrumented with polyetheretherketone (PEEK) rods would be greater than metal rods and lower than noninstrumented controls. Further, adjacent segment motion was expected to be lower with polymer rods compared to conventional systems. Methods Biomechanical tests were conducted on 6 skeletally immature porcine thoracic spines (domestic swine, 35-40 kg). Spines were harvested after death from swine that had been utilized for other studies (IACUC approved) which had not involved the spine. Paired pedicle screws were used as anchors at proximal and distal levels. Specimens were tested under the following conditions: control, then dual rods of PEEK (6.25 mm), titanium (4 mm), and CoCr (5 mm) alloy. Lateral bending (LB) and flexion-extension (FE) moments of ±5 Nm were applied. Vertebral rotations were measured using video. Differences were determined by two-tailed t-tests and Bonferroni correction with four primary comparisons: PEEK vs control and PEEK vs CoCr, in LB and FE (α=0.05/4). Results In LB, ROM of specimens with PEEK rods was lower than control at each instrumented level. ROM was greater for PEEK rods than both Ti and CoCr at every instrumented level. Mean ROM at proximal and distal noninstrumented levels was lower for PEEK than for Ti and CoCr. In FE, mean ROM at proximal and distal noninstrumented levels was lower for PEEK than for metal. Combining treated levels, in LB, ROM for PEEK rods was 35% of control (p<0.0001) and 270% of CoCr rods (p<0.01). In FE, ROM with PEEK was 27% of control (p<0.001) and 180% of CoCr (p<0.01). Conclusions PEEK rods decreased flexibility versus noninstumented controls, and increased flexibility versus metal rods. Smaller increases in ROM at proximal and distal adjacent motion segments occurred with PEEK compared to metal rods, which may help decrease junctional kyphosis. Flexible growing rods may eventually help improve treatment options for young patients with severe deformity. PMID:25810752
Development of advanced strain diagnostic techniques for reactor environments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fleming, Darryn D.; Holschuh, Thomas Vernon,; Miller, Timothy J.
2013-02-01
The following research is operated as a Laboratory Directed Research and Development (LDRD) initiative at Sandia National Laboratories. The long-term goals of the program include sophisticated diagnostics of advanced fuels testing for nuclear reactors for the Department of Energy (DOE) Gen IV program, with the future capability to provide real-time measurement of strain in fuel rod cladding during operation in situ at any research or power reactor in the United States. By quantifying the stress and strain in fuel rods, it is possible to significantly improve fuel rod design, and consequently, to improve the performance and lifetime of the cladding.more » During the past year of this program, two sets of experiments were performed: small-scale tests to ensure reliability of the gages, and reactor pulse experiments involving the most viable samples in the Annulated Core Research Reactor (ACRR), located onsite at Sandia. Strain measurement techniques that can provide useful data in the extreme environment of a nuclear reactor core are needed to characterize nuclear fuel rods. This report documents the progression of solutions to this issue that were explored for feasibility in FY12 at Sandia National Laboratories, Albuquerque, NM.« less
Coupling procedure for TRANSURANUS and KTF codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jimenez, J.; Alglave, S.; Avramova, M.
2012-07-01
The nuclear industry aims to ensure safe and economic operation of each single fuel rod introduced in the reactor core. This goal is even more challenging nowadays due to the current strategy of going for higher burn-up (fuel cycles of 18 or 24 months) and longer residence time. In order to achieve that goal, fuel modeling is the key to predict the fuel rod behavior and lifetime under thermal and pressure loads, corrosion and irradiation. In this context, fuel performance codes, such as TRANSURANUS, are used to improve the fuel rod design. The modeling capabilities of the above mentioned toolsmore » can be significantly improved if they are coupled with a thermal-hydraulic code in order to have a better description of the flow conditions within the rod bundle. For LWR applications, a good representation of the two phase flow within the fuel assembly is necessary in order to have a best estimate calculation of the heat transfer inside the bundle. In this paper we present the coupling methodology of TRANSURANUS with KTF (Karlsruhe Two phase Flow subchannel code) as well as selected results of the coupling proof of principle. (authors)« less
NASA Astrophysics Data System (ADS)
Class, G.; Meyder, R.; Stratmanns, E.
1985-12-01
The large data base for validation and development of computer codes for two-phase flow, generated at the COSIMA facility, is reviewed. The aim of COSIMA is to simulate the hydraulic, thermal, and mechanical conditions in the subchannel and the cladding of fuel rods in pressurized water reactors during the blowout phase of a loss of coolant accident. In terms of fuel rod behavior, it is found that during blowout under realistic conditions only small strains are reached. For cladding rupture extremely high rod internal pressures are necessary. The behavior of fuel rod simulators and the effect of thermocouples attached to the cladding outer surface are clarified. Calculations performed with the codes RELAP and DRUFAN show satisfactory agreement with experiments. This can be improved by updating the phase separation models in the codes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-08-01
The Record of Decision Amendment (`ROD Amendment`) modifies the selected remedy described in the Revised Record of Decision for the Tyson`s Superfund Site (Site) issued by the U.S. Environmental Protection Agency (EPA) on March 31, 1988 (1988 Revised ROD - PB89-233894). In the 1988 Revised ROD, EPA selected a soil vapor extraction (SVE) remedy for lagoon area soils. The SVE system has removed approximately 200,000 pounds of volatile organic compounds (VOCs) from the lagoon area soils. Although several enhancements and modifications have been employed to improve performance, the SVE system will not achieve the cleanup standards specified in the 1988more » Revised ROD. The decision document presents the selected remedial action for the lagoon area soils at the Tyson`s Site.« less
Wahlgren, Carl-Fredrik; Edelbring, Samuel; Fors, Uno; Hindbeck, Hans; Ståhle, Mona
2006-01-01
Background Most of the many computer resources used in clinical teaching of dermatology and venereology for medical undergraduates are information-oriented and focus mostly on finding a "correct" multiple-choice alternative or free-text answer. We wanted to create an interactive computer program, which facilitates not only factual recall but also clinical reasoning. Methods Through continuous interaction with students, a new computerised interactive case simulation system, NUDOV, was developed. It is based on authentic cases and contains images of real patients, actors and healthcare providers. The student selects a patient and proposes questions for medical history, examines the skin, and suggests investigations, diagnosis, differential diagnoses and further management. Feedback is given by comparing the user's own suggestions with those of a specialist. In addition, a log file of the student's actions is recorded. The program includes a large number of images, video clips and Internet links. It was evaluated with a student questionnaire and by randomising medical students to conventional teaching (n = 85) or conventional teaching plus NUDOV (n = 31) and comparing the results of the two groups in a final written examination. Results The questionnaire showed that 90% of the NUDOV students stated that the program facilitated their learning to a large/very large extent, and 71% reported that extensive working with authentic computerised cases made it easier to understand and learn about diseases and their management. The layout, user-friendliness and feedback concept were judged as good/very good by 87%, 97%, and 100%, respectively. Log files revealed that the students, in general, worked with each case for 60–90 min. However, the intervention group did not score significantly better than the control group in the written examination. Conclusion We created a computerised case simulation program allowing students to manage patients in a non-linear format supporting the clinical reasoning process. The student gets feedback through comparison with a specialist, eliminating the need for external scoring or correction. The model also permits discussion of case processing, since all transactions are stored in a log file. The program was highly appreciated by the students, but did not significantly improve their performance in the written final examination. PMID:16907972
Mortality Benefits of Antibiotic Computerised Decision Support System: Modifying Effects of Age.
Chow, Angela L P; Lye, David C; Arah, Onyebuchi A
2015-11-30
Antibiotic computerised decision support systems (CDSSs) are shown to improve antibiotic prescribing, but evidence of beneficial patient outcomes is limited. We conducted a prospective cohort study in a 1500-bed tertiary-care hospital in Singapore, to evaluate the effectiveness of the hospital's antibiotic CDSS on patients' clinical outcomes, and the modification of these effects by patient factors. To account for clustering, we used multilevel logistic regression models. One-quarter of 1886 eligible inpatients received CDSS-recommended antibiotics. Receipt of antibiotics according to CDSS's recommendations seemed to halve mortality risk of patients (OR 0.54, 95% CI 0.26-1.10, P = 0.09). Patients aged ≤65 years had greater mortality benefit (OR 0.45, 95% CI 0.20-1.00, P = 0.05) than patients that were older than 65 (OR 1.28, 95% CI 0.91-1.82, P = 0.16). No effect was observed on incidence of Clostridium difficile (OR 1.02, 95% CI 0.34-3.01), and multidrug-resistant organism (OR 1.06, 95% CI 0.42-2.71) infections. No increase in infection-related readmission (OR 1.16, 95% CI 0.48-2.79) was found in survivors. Receipt of CDSS-recommended antibiotics reduced mortality risk in patients aged 65 years or younger and did not increase the risk in older patients. Physicians should be informed of the benefits to increase their acceptance of CDSS recommendations.
Two-phase pressure drop reduction BWR assembly design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dix, G.E.; Crowther, R.L.; Colby, M.J.
1992-05-12
This patent describes a boiling water reactor having discrete bundles of fuel rods confined within channel enclosed fuel assemblies, an improvement to a fuel bundle assembly for placement in the reactor. It comprises a fuel channel having vertically extending walls forming a continuous channel around a fuel assembly volume, the channel being open at the bottom end for engagement to a lower tie plate and open at the upper end for engagement to an upper tie plate; rods for placement within the chamber, each the rod containing fissile material for producing nuclear reaction when in the presence of sufficient moderatedmore » neutron flux; a lower tie plate for supporting the bundle of rods within the channel, the lower tie plate for supporting the bundle of rods within the channel, the lower tie plate joining the bottom of the channel to close the bottom end of the channel, the lower tie plate providing defined apertures for the inflow of water in the channel between the rods for the generating of steam during the nuclear reaction; the plurality of fuel rods extending from the lower tie plate wherein a single phase region of the water in the bundle is defined to an upward portion of the bundle wherein a two phase region of the water and steam in the bundle is defined during nuclear steam generating reaction in the fuel bundle.« less
Pearcy, Caitlin P; Anderson, Rebecca A; Egan, Sarah J; Rees, Clare S
2016-06-01
The presence of obsessive-compulsive disorder (OCD) can result in low quality of life, with significant impairments in social and occupational functioning. An increase in the dissemination of self-help programs has been observed in the treatment of OCD, and has provided improved accessibility to treatment. The present study examined the efficacy of self-help interventions for OCD in the context of therapeutic contact. Randomised controlled trials and quasi-experimental studies were identified through computerised database searches. Self-help format (bibliotherapy, internet-based, computerised), and therapeutic contact were examined for their effect on treatment outcomes. Eighteen studies targeting self-help for OCD met inclusion criteria with 1570 participants. The average post-treatment effect size (Hedges' g) of self-help interventions on primary outcomes was .51 (95% CI: .41 to 0.61). Subgroup analysis revealed large effect sizes for minimal-contact self-help (g = 0.91, 95% CI: 0.66 to 1.17), moderate effect sizes for predominantly self-help (g = 0.68, 95% CI: 0.40 to 0.96), and small effect sizes for self-administered self-help (g = 0.33, 95% CI: .18 to 0.47). A large variation of treatment approaches, amount of therapeutic contact, and risk of bias within each study may account for the large magnitude in effect sizes across studies. Additionally, the long-term follow-up effects of treatment approaches were not examined. A growing body of literature supporting to the use of self-help treatments for OCD is evident, however, further investigation through use of randomised controlled trials is required, particularly the use of stepped care and long-term effectiveness. Copyright © 2015 Elsevier Ltd. All rights reserved.
Young, A; Dixon, A; Getty, J; Renton, P; Vacher, H
1981-06-01
A case of the cauda equina syndrome complicating ankylosing spondylitis (AS) is described. An unusual feature of this case was the relapsing and remitting nature of the condition, but there is sufficient evidence to explain the clinical picture on the basis of a recurrent intraspinal inflammatory process. The clinical and radiological features are similar to those of a further 28 reported in the literature. An electromyogram (EMG) proved important in defining the extent of neurological involvement. Computerised tomography (CT) showed marked laminar erosion and no bony exit foramen encroachment. We believe that the clinical diagnosis of this condition can be adequately confirmed with plain radiology, EMG, and CT scan.
Cushion, Christopher; Harvey, Stephen; Muir, Bob; Nelson, Lee
2012-01-01
We outline the evolution of a computerised systematic observation tool and describe the process for establishing the validity and reliability of this new instrument. The Coach Analysis and Interventions System (CAIS) has 23 primary behaviours related to physical behaviour, feedback/reinforcement, instruction, verbal/non-verbal, questioning and management. The instrument also analyses secondary coach behaviour related to performance states, recipient, timing, content and questioning/silence. The CAIS is a multi-dimensional and multi-level mechanism able to provide detailed and contextualised data about specific coaching behaviours occurring in complex and nuanced coaching interventions and environments that can be applied to both practice sessions and competition.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crowther, R.L.; Johansson, E.B.
1988-06-07
A fuel assembly is described comprising fuel rods positioned in a spaced array by upper and lower tie-plates, an open ended flow channel surrounding the array for conducting coolant upward about the fuel rods, the open ended channel having a polygon shaped cross section with flat side sections connected between the corner sections; means separate from the channel connecting the upper and lower tie-plates together and maintaining the fuel rods in spaced array independent of the flow channel, improvement in the flow channel comprising: four corners having a first thickness; four sides having a second and reduced thickness from themore » corner thickness, the sides welded to the corner sections.« less
Effect of luminosity on color discrimination of dichromatic marmosets (Callithrix jacchus).
Freitag, Fabio Batista; Pessoa, Daniel Marques Almeida
2012-02-01
Psychophysical data have shown that under mesopic conditions cones and rods can interact, improving color vision. Since electrophysiological data have suggested that rods of dichromatic marmosets appear to be active at higher luminance, we aimed to investigate the effect of different levels of sunlight on the foraging abilities of male dichromatic marmosets. Captive marmosets were observed under three different conditions, with respect to their performance in detecting colored food items against a green background. Compared to high and low light intensities, intermediate luminosities significantly increased detection of orange targets by male dichromats, an indication of rod intrusion. © 2012 Optical Society of America
Van de Velde, Stijn; Roshanov, Pavel; Kortteisto, Tiina; Kunnamo, Ilkka; Aertgeerts, Bert; Vandvik, Per Olav; Flottorp, Signe
2016-03-05
A computerised clinical decision support system (CCDSS) is a technology that uses patient-specific data to provide relevant medical knowledge at the point of care. It is considered to be an important quality improvement intervention, and the implementation of CCDSS is growing substantially. However, the significant investments do not consistently result in value for money due to content, context, system and implementation issues. The Guideline Implementation with Decision Support (GUIDES) project aims to improve the impact of CCDSS through optimised implementation based on high-quality evidence-based recommendations. To achieve this, we will develop tools that address the factors that determine successful CCDSS implementation. We will develop the GUIDES tools in four steps, using the methods and results of the Tailored Implementation for Chronic Diseases (TICD) project as a starting point: (1) a review of research evidence and frameworks on the determinants of implementing recommendations using CCDSS; (2) a synthesis of a comprehensive framework for the identified determinants; (3) the development of tools for use of the framework and (4) pilot testing the utility of the tools through the development of a tailored CCDSS intervention in Norway, Belgium and Finland. We selected the conservative management of knee osteoarthritis as a prototype condition for the pilot. During the process, the authors will collaborate with an international expert group to provide input and feedback on the tools. This project will provide guidance and tools on methods of identifying implementation determinants and selecting strategies to implement evidence-based recommendations through CCDSS. We will make the GUIDES tools available to CCDSS developers, implementers, researchers, funders, clinicians, managers, educators, and policymakers internationally. The tools and recommendations will be generic, which makes them scalable to a large spectrum of conditions. Ultimately, the better implementation of CCDSS may lead to better-informed decisions and improved care and patient outcomes for a wide range of conditions. PROSPERO, CRD42016033738.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Connor, Michael J.; Department of Radiation Oncology, University of California Irvine School of Medicine, Irvine, California; Marshall, Deborah C.
Purpose: Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE) database, comparing these with non–radiation oncology devices. Methods and Materials: MAUDE data on RODs from 1991 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems) and 5 device problem categories (software, mechanical, electrical, user error, and dose delivery impact).more » Outcomes included whether the device was evaluated by the manufacturer, adverse event type, remedial action, problem code, device age, and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by the Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 4234 ROD and 4,985,698 other device adverse event reports. Adverse event reports increased over time, and events involving RODs peaked in 2011. Most ROD reports involved external beam therapy (50.8%), followed by brachytherapy (24.9%) and treatment planning systems (21.6%). The top problem types were software (30.4%), mechanical (20.9%), and user error (20.4%). RODs differed significantly from other devices in each outcome (P<.001). RODs were more likely to be evaluated by the manufacturer after an event (46.9% vs 33.0%) but less likely to be recalled (10.5% vs 37.9%) (P<.001). Device age and time since 510(k) approval were shorter among RODs (P<.001). Conclusions: Compared with other devices, RODs may experience adverse events sooner after manufacture and market approval. Close postmarket surveillance, improved software design, and manufacturer–user training may help mitigate these events.« less
Computerised analysis of facial emotion expression in eating disorders
2017-01-01
Background Problems with social-emotional processing are known to be an important contributor to the development and maintenance of eating disorders (EDs). Diminished facial communication of emotion has been frequently reported in individuals with anorexia nervosa (AN). Less is known about facial expressivity in bulimia nervosa (BN) and in people who have recovered from AN (RecAN). This study aimed to pilot the use of computerised facial expression analysis software to investigate emotion expression across the ED spectrum and recovery in a large sample of participants. Method 297 participants with AN, BN, RecAN, and healthy controls were recruited. Participants watched film clips designed to elicit happy or sad emotions, and facial expressions were then analysed using FaceReader. Results The finding mirrored those from previous work showing that healthy control and RecAN participants expressed significantly more positive emotions during the positive clip compared to the AN group. There were no differences in emotion expression during the sad film clip. Discussion These findings support the use of computerised methods to analyse emotion expression in EDs. The findings also demonstrate that reduced positive emotion expression is likely to be associated with the acute stage of AN illness, with individuals with BN showing an intermediate profile. PMID:28575109
Bowman, Caroline H; Evans, Cathryn E Y; Turnbull, Oliver H
2005-02-01
In the last decade, the Iowa Gambling Task (IGT) has become a widely employed neuropsychological research instrument for the investigation of executive function. The task has been employed in a wide range of formats, from 'manual' procedures to more recently introduced computerised versions. Computer-based formats often require that responses on the task should be artificially delayed by a number of seconds between trials to collect skin-conductance data. Participants, however, may become frustrated when they want to select from a particular deck in the time-limited versions--so that an unintended emotional experience of frustration might well disrupt a task presumed to be reliant on emotion-based learning. We investigated the effect of the various types of Iowa Gambling Task format on performance, using three types of task: the classic manual administration, with no time limitations; a computerised administration with a 6-s enforced delay; and a control computerised version which had no time constraints. We also evaluated the subjective experience of participants on each task. There were no significant differences in performance, between formats, in behavioural terms. Subjective experience measures on the task also showed consistent effects across all three formats-with substantial, and rapidly developing, awareness of which decks were 'good' and 'bad.'
Thresholds and noise limitations of colour vision in dim light
Yovanovich, Carola
2017-01-01
Colour discrimination is based on opponent photoreceptor interactions, and limited by receptor noise. In dim light, photon shot noise impairs colour vision, and in vertebrates, the absolute threshold of colour vision is set by dark noise in cones. Nocturnal insects (e.g. moths and nocturnal bees) and vertebrates lacking rods (geckos) have adaptations to reduce receptor noise and use chromatic vision even in very dim light. In contrast, vertebrates with duplex retinae use colour-blind rod vision when noisy cone signals become unreliable, and their transition from cone- to rod-based vision is marked by the Purkinje shift. Rod–cone interactions have not been shown to improve colour vision in dim light, but may contribute to colour vision in mesopic light intensities. Frogs and toads that have two types of rods use opponent signals from these rods to control phototaxis even at their visual threshold. However, for tasks such as prey or mate choice, their colour discrimination abilities fail at brighter light intensities, similar to other vertebrates, probably limited by the dark noise in cones. This article is part of the themed issue 'Vision in dim light’. PMID:28193810
Vibration Method for Tracking the Resonant Mode and Impedance of a Microwave Cavity
NASA Technical Reports Server (NTRS)
Barmatz, M.; Iny, O.; Yiin, T.; Khan, I.
1995-01-01
A vibration technique his been developed to continuously maintain mode resonance and impedance much between a constant frequency magnetron source and resonant cavity. This method uses a vibrating metal rod to modulate the volume of the cavity in a manner equivalent to modulating an adjustable plunger. A similar vibrating metal rod attached to a stub tuner modulates the waveguide volume between the source and cavity. A phase sensitive detection scheme determines the optimum position of the adjustable plunger and stub turner during processing. The improved power transfer during the heating of a 99.8% pure alumina rod was demonstrated using this new technique. Temperature-time and reflected power-time heating curves are presented for the cases of no tracking, impedance tracker only, mode tracker only and simultaneous impedance and mode tracking. Controlled internal melting of an alumina rod near 2000 C using both tracking units was also demonstrated.
Characterisation of Plasma Filled Rod Pinch electron beam diode operation
NASA Astrophysics Data System (ADS)
MacDonald, James; Bland, Simon; Chittenden, Jeremy
2016-10-01
The plasma filled rod pinch diode (aka PFRP) offers a small radiographic spot size and a high brightness source. It operates in a very similar to plasma opening switches and dense plasma focus devices - with a plasma prefill, supplied via a number of simple coaxial plasma guns, being snowploughed along a thin rod cathode, before detaching at the end. The aim of this study is to model the PFRP and understand the factors that affect its performance, potentially improving future output. Given the dependence on the PFRP on the prefill, we are making detailed measurements of the density (1015-1018 cm-3), velocity, ionisation and temperature of the plasma emitted from a plasma gun/set of plasma guns. This will then be used to provide initial conditions to the Gorgon 3D MHD code, and the dynamics of the entire rod pinch process studied.
Laser rods with undoped, flanged end-caps for end-pumped laser applications
Meissner, Helmuth E.; Beach, Raymond J.; Bibeau, Camille; Sutton, Steven B.; Mitchell, Scott; Bass, Isaac; Honea, Eric
1999-01-01
A method and apparatus for achieving improved performance in a solid state laser is provided. A flanged, at least partially undoped end-cap is attached to at least one end of a laserable medium. Preferably flanged, undoped end-caps are attached to both ends of the laserable medium. Due to the low scatter requirements for the interface between the end-caps and the laser rod, a non-adhesive method of bonding is utilized such as optical contacting combined with a subsequent heat treatment of the optically contacted composite. The non-bonded end surfaces of the flanged end-caps are coated with laser cavity coatings appropriate for the lasing wavelength of the laser rod. A cooling jacket, sealably coupled to the flanged end-caps, surrounds the entire length of the laserable medium. Radiation from a pump source is focussed by a lens duct and passed through at least one flanged end-cap into the laser rod.
Computerised respiratory sounds can differentiate smokers and non-smokers.
Oliveira, Ana; Sen, Ipek; Kahya, Yasemin P; Afreixo, Vera; Marques, Alda
2017-06-01
Cigarette smoking is often associated with the development of several respiratory diseases however, if diagnosed early, the changes in the lung tissue caused by smoking may be reversible. Computerised respiratory sounds have shown to be sensitive to detect changes within the lung tissue before any other measure, however it is unknown if it is able to detect changes in the lungs of healthy smokers. This study investigated the differences between computerised respiratory sounds of healthy smokers and non-smokers. Healthy smokers and non-smokers were recruited from a university campus. Respiratory sounds were recorded simultaneously at 6 chest locations (right and left anterior, lateral and posterior) using air-coupled electret microphones. Airflow (1.0-1.5 l/s) was recorded with a pneumotachograph. Breathing phases were detected using airflow signals and respiratory sounds with validated algorithms. Forty-four participants were enrolled: 18 smokers (mean age 26.2, SD = 7 years; mean FEV 1 % predicted 104.7, SD = 9) and 26 non-smokers (mean age 25.9, SD = 3.7 years; mean FEV 1 % predicted 96.8, SD = 20.2). Smokers presented significantly higher frequency at maximum sound intensity during inspiration [(M = 117, SD = 16.2 Hz vs. M = 106.4, SD = 21.6 Hz; t(43) = -2.62, p = 0.0081, d z = 0.55)], lower expiratory sound intensities (maximum intensity: [(M = 48.2, SD = 3.8 dB vs. M = 50.9, SD = 3.2 dB; t(43) = 2.68, p = 0.001, d z = -0.78)]; mean intensity: [(M = 31.2, SD = 3.6 dB vs. M = 33.7,SD = 3 dB; t(43) = 2.42, p = 0.001, d z = 0.75)] and higher number of inspiratory crackles (median [interquartile range] 2.2 [1.7-3.7] vs. 1.5 [1.2-2.2], p = 0.081, U = 110, r = -0.41) than non-smokers. Significant differences between computerised respiratory sounds of smokers and non-smokers have been found. Changes in respiratory sounds are often the earliest sign of disease. Thus, computerised respiratory sounds might be a promising measure to early detect smoking related respiratory diseases.
Strengthening of oxidation resistant materials for gas turbine applications
NASA Technical Reports Server (NTRS)
Platts, D. R.; Kirchner, H. P.; Gruver, R. M.
1972-01-01
Compressive surface layers were formed on hot-pressed silicon carbide and nitride. The objective of these treatments was to improve the impact resistance of these materials at 1590 K (2400 F). Quenching was used to form compressive surface layers on silicon carbide. The presence of the compressive stresses was demonstrated by slotted rod tests. Compressive stresses were retained at elevated temperatures. Improvements in impact resistance at 1590 K (2400 F) and flexural strength at room temperature were achieved using cylindrical rods 3.3 mm (0.13 in.) in diameter. Carburizing treatments were used to form the surface layers on silicon nitride. In a few cases using rectangular bars improvements in impact resistance at 1590 K (2400 F) were observed.
Computerisation of diabetic clinic records.
Watkins, G B; Sutcliffe, T; Pyke, D A; Watkins, P J
1980-01-01
A simple system for putting diabetic records on a computer file is achieved by using stationery that combines the usual handwritten records (not computerised) with the minimum of essential data suitable for punching on to computer tape. The record may be brought up to date at a selected time time interval. This simple, cheap system has been in use in a busy clinic for six years. The information on about 8000 diabetics now held in the computer file is used chiefly to help research by creating registers of patients with specified characteristics, such as treatment, heredity complications, and pregnancy. A complete up-to-date index of the entire clinic population is always available, and routine clinic statistics are returned every six months. PMID:7437814
NASA Astrophysics Data System (ADS)
Mow, M.; Zbijewski, W.; Sisniega, A.; Xu, J.; Dang, H.; Stayman, J. W.; Wang, X.; Foos, D. H.; Koliatsos, V.; Aygun, N.; Siewerdsen, J. H.
2017-03-01
Purpose: To improve the timely detection and treatment of intracranial hemorrhage or ischemic stroke, recent efforts include the development of cone-beam CT (CBCT) systems for perfusion imaging and new approaches to estimate perfusion parameters despite slow rotation speeds compared to multi-detector CT (MDCT) systems. This work describes development of a brain perfusion CBCT method using a reconstruction of difference (RoD) approach to enable perfusion imaging on a newly developed CBCT head scanner prototype. Methods: A new reconstruction approach using RoD with a penalized-likelihood framework was developed to image the temporal dynamics of vascular enhancement. A digital perfusion simulation was developed to give a realistic representation of brain anatomy, artifacts, noise, scanner characteristics, and hemo-dynamic properties. This simulation includes a digital brain phantom, time-attenuation curves and noise parameters, a novel forward projection method for improved computational efficiency, and perfusion parameter calculation. Results: Our results show the feasibility of estimating perfusion parameters from a set of images reconstructed from slow scans, sparse data sets, and arc length scans as short as 60 degrees. The RoD framework significantly reduces noise and time-varying artifacts from inconsistent projections. Proper regularization and the use of overlapping reconstructed arcs can potentially further decrease bias and increase temporal resolution, respectively. Conclusions: A digital brain perfusion simulation with RoD imaging approach has been developed and supports the feasibility of using a CBCT head scanner for perfusion imaging. Future work will include testing with data acquired using a 3D-printed perfusion phantom currently and translation to preclinical and clinical studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miura, S., E-mail: miura-syun12@ees.nagoya-u.ac.jp; Yoshida, Y.; Ichino, Y.
For use in high-magnetic-field coil-based applications, the critical current density (J{sub c}) of REBa{sub 2}Cu{sub 3}O{sub y} (REBCO, where RE = rare earth) coated conductors must be isotropically improved, with respect to the direction of the magnetic field; these improvements must be realized at the operating conditions of these applications. In this study, improvement of the J{sub c} for various applied directions of magnetic field was achieved by controlling the morphology of the BaHfO{sub 3} (BHO) nano-rods in a SmBCO film. We fabricated the 3.0 vol. % BHO-doped SmBCO film at a low growth temperature of 720 °C, by using amore » seed layer technique (T{sub s} = 720 °C film). The low-temperature growth resulted in a morphological change in the BHO nano-rods. In fact, a high number density of (3.1 ± 0.1) × 10{sup 3} μm{sup −2} of small (diameter: 4 ± 1 nm), discontinuous nano-rods that grew in various directions, was obtained. In J{sub c} measurements, the J{sub c} of the T{sub s} = 720 °C film in all directions of the applied magnetic field was higher than that of the non-doped SmBCO film. The J{sub c}{sup min} (6.4 MA/cm{sup 2}) of the former was more than 6 times higher than that (1.0 MA/cm{sup 2}) of the latter at 40 K, under 3 T. The aforementioned results indicated that the discontinuous BHO nano-rods, which occurred with a high number density, exerted a 3D-like flux pinning at the measurement conditions considered. Moreover, at 4.2 K and under 17 T, a flux pinning force density of 1.6 TN/m{sup 3} was realized; this value was comparable to the highest value recorded, to date.« less
Wang, Weiwei; Townes-Anderson, Ellen
2015-01-01
Purpose Rod photoreceptors retract their axon terminals and develop neuritic sprouts in response to retinal detachment and reattachment, respectively. This study examines the role of LIM kinase (LIMK), a component of RhoA and Rac pathways, in the presynaptic structural remodeling of rod photoreceptors. Methods Phosphorylated LIMK (p-LIMK), the active form of LIMK, was examined in salamander retina with Western blot and confocal microscopy. Axon length within the first 7 hours and process growth after 3 days of culture were assessed in isolated rod photoreceptors treated with inhibitors of upstream regulators ROCK and p21-activated kinase (Pak) (Y27632 and IPA-3) and a direct LIMK inhibitor (BMS-5). Porcine retinal explants were also treated with BMS-5 and analyzed 24 hours after detachment. Because Ca2+ influx contributes to axonal retraction, L-type channels were blocked in some experiments with nicardipine. Results Phosphorylated LIMK is present in rod terminals during retraction and in newly formed processes. Axonal retraction over 7 hours was significantly reduced by inhibition of LIMK or its regulators, ROCK and Pak. Process growth was reduced by LIMK or Pak inhibition especially at the basal (axon-bearing) region of the rod cells. Combining Ca2+ channel and LIMK inhibition had no additional effect on retraction but did further inhibit sprouting after 3 days. In detached porcine retina, LIMK inhibition reduced rod axonal retraction and improved retinal morphology. Conclusions Thus structural remodeling, in the form of either axonal retraction or neuritic growth, requires LIMK activity. LIM kinase inhibition may have therapeutic potential for reducing pathologic rod terminal plasticity after retinal injury. PMID:26658506
Biomechanical stability according to different configurations of screws and rods.
Ha, Kee-Yong; Hwang, Sung-Chul; Whang, Tae-Hyuk
2013-05-01
Comparison of biomechanical strength according to 2 different configurations of screws and rods. To compare the biomechanical strength of different configurations of screws and rods composed of the same material and of the same size. Many complications related to instrumentation have been reported. The incidence of metallic failure would differ according to the materials and configurations of the assembly of the screws and rods used. However, to our knowledge, the biomechanical effects of implant assembly rods and screws with different configurations and different contours have not been reported. Biomechanical testing was conducted to compare top tightening (TT) screw-rod configuration with side tightening (ST) screw-rod configuration. All tests were conducted using a hydraulic all-purpose testing machine. All data were acquired at a rate of 10 Hz. Both screw systems used spinal rods of 6 mm diameter and were made of TiAl4V ELI material. Among 5 types of tests, 3 were conducted on the basis of American Society for Testing and Materials (ASTM) F 1798 to 97 and F1717-10. The other 2 tests were conducted for comparing the characteristics between TT and ST pedicle screws according to modified methods from ASTM F 1717-10 and ASTM F 1798-97. All results including axial gripping capacity and yield forces were obtained using the same methods on the basis of the mentioned ASTM standards. In the axial gripping capacity test, the mean axial gripping capacity of the TT screw-rod configuration was 3332 ± 118 N and that of ST was 2222 ± 147 N in straight rods (P = 0.019). In 15-degree contoured rods, TT was 2988 ± 199 N and ST was 2116 ± 423 N (P = 0.014). In 30-degree contoured rods, TT was 2227 ± 408 N and ST was 1814 ± 285 N (P = 0.009). In the pulling-out test, the pulling-out force of ST was 8695 ± 1616 N and that of TT was 6106 ± 195 N (P = 0.014). In the rod-pushing test, the failure force of ST was 4131 ± 205 N and that of TT was 5639 ± 105 N. In the compressive fatigue test, the maximum load was 145 N in ST and 119 N in TT. In the cycle fatigue test, the fatigue strength of ST was higher than that of TT. In the rod-pushing test, the failure force of ST was 4131 ± 205 N and that of TT was 5639 ± 105 N (P=0.046). Two different configurations of rod-screw systems found statistically significant differences with axial gripping, pulling out, and fatigue failures. ST constructs improved fixation stability over TT constructs. It was concluded that ST configuration may reduce complications related to implantation.
Review of CTF s Fuel Rod Modeling Using FRAPCON-4.0 s Centerline Temperature Predictions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toptan, Aysenur; Salko, Robert K; Avramova, Maria
Coolant Boiling in Rod Arrays Two Fluid (COBRA-TF), or CTF1 [1], is a nuclear thermal hydraulic subchannel code used throughout academia and industry. CTF s fuel rod modeling is originally developed for VIPRE code [2]. Its methodology is based on GAPCON [3] and FRAP [4] fuel performance codes, and material properties are included from MATPRO handbook [5]. This work focuses on review of CTF s fuel rod modeling to address shortcomings in CTF s temperature predictions. CTF is compared to FRAPCON which is U.S. NRC s steady-state fuel performance code for light-water reactor fuel rods. FRAPCON calculates the changes inmore » fuel rod variables and temperatures including the eects of cladding hoop strain, cladding oxidation, hydriding, fuel irradiation swelling, densification, fission gas release and rod internal gas pressure. It uses fuel, clad and gap material properties from MATPRO. Additionally, it has its own models for fission gas release, cladding corrosion and cladding hydrogen pickup. It allows finite dierence or finite element approaches for its mechanical model. In this study, FRAPCON-4.0 [6] is used as a reference fuel performance code. In comparison, Halden Reactor Data for IFA432 Rod 1 and Rod 3. CTF simulations are performed in two ways; informing CTF with gap conductance value from FRAPCON, and using CTF s dynamic gap conductance model. First case is chosen to show temperature is predicted correctly with CTF s models for thermal and cladding conductivities once gap conductance is provided. Latter is to review CTF s dynamic gap conductance model. These Halden test cases are selected to be representative of cases with and without any physical contact between fuel-pellet and clad while reviewing functionality of CTF s dynamic gap conductance model. Improving the CTF s dynamic gap conductance model will allow prediction of fuel and cladding thermo-mechanical behavior under irradiation, and better temperature feedbacks from CTF in transient calculations.« less
Dynamical theory of stability for elastic rods with nonlinear curvature and twist
NASA Technical Reports Server (NTRS)
Wauer, J.
1977-01-01
Considering non-linear terms in the curvature as well as in the twist, the governing boundary value problem for lateral bending of elastic, transverse loaded rods is formulated by means of Hamilton's principle. Using the method of small vibrations, the associated linearized equations of stability are derived, which complete the currently accepted relations. The example of the simplest lateral bending problem illustrates the improved effect of the proposed equations.
Hofman, D; Monte, L; Boyer, P; Brittain, J; Donchyts, G; Gallego, E; Gheorghiu, D; Håkanson, L; Heling, R; Kerekes, A; Kocsy, G; Lepicard, S; Slavik, O; Slavnicu, D; Smith, J; Zheleznyak, M
2011-02-01
Assessment of the environmental and radiological consequences of a nuclear accident requires the management of a great deal of data and information as well as the use of predictive models. Computerised Decision Support Systems (CDSS) are essential tools for this kind of complex assessment and for assisting experts with a rational decision process. The present work focuses on the assessment of the main features of selected state-of-the-art CDSS for off-site management of freshwater ecosystems contaminated by radionuclides. This study involved both developers and end-users of the assessed CDSS and was based on practical customisation exercises, installation and application of the decision systems. Potential end-users can benefit from the availability of several ready-to-use CDSS that allow one to run different kinds of models aimed at predicting the behaviour of radionuclides in aquatic ecosystems, evaluating doses to humans, assessing the effectiveness of different kinds of environmental management interventions and ranking these interventions, accounting for their social, economic and environmental impacts. As a result of the present assessment, the importance of CDSS "integration" became apparent: in many circumstances, different CDSS can be used as complementary tools for the decision-making process. The results of this assessment can also be useful for the future development and improvement of the CDSS. Copyright © 2010 Elsevier Ltd. All rights reserved.
Managing laboratory test ordering through test frequency filtering.
Janssens, Pim M W; Wasser, Gerd
2013-06-01
Modern computer systems allow limits to be set on the periods allowed for repetitive testing. We investigated a computerised system for managing potentially overtly frequent laboratory testing, calculating the financial savings obtained. In consultation with hospital physicians, tests were selected for which 'spare periods' (periods during which tests are barred) might be set to control repetitive testing. The tests were selected and spare periods determined based on known analyte variations in health and disease, variety of tissues or cells giving rise to analytes, clinical conditions and rate of change determining analyte levels, frequency with which doctors need information about the analytes and the logistical needs of the clinic. The operation and acceptance of the system was explored with 23 analytes. Frequency filtering was subsequently introduced for 44 tests, each with their own spare periods. The proportion of tests barred was 0.56%, the most frequent of these being for total cholesterol, uric acid and HDL-cholesterol. The financial savings were 0.33% of the costs of all testing, with HbA1c, HDL-cholesterol and vitamin B12 yielding the largest savings. Following the introduction of the system the number of barred tests ultimately decreased, suggesting accommodation by the test requestors. Managing laboratory testing through computerised limits to prevent overtly frequent testing is feasible. The savings were relatively low, but sustaining the system takes little effort, giving little reason not to apply it. The findings will serve as a basis for improving the system and may guide others in introducing similar systems.
Mortality Benefits of Antibiotic Computerised Decision Support System: Modifying Effects of Age
Chow, Angela L. P.; Lye, David C.; Arah, Onyebuchi A.
2015-01-01
Antibiotic computerised decision support systems (CDSSs) are shown to improve antibiotic prescribing, but evidence of beneficial patient outcomes is limited. We conducted a prospective cohort study in a 1500-bed tertiary-care hospital in Singapore, to evaluate the effectiveness of the hospital’s antibiotic CDSS on patients’ clinical outcomes, and the modification of these effects by patient factors. To account for clustering, we used multilevel logistic regression models. One-quarter of 1886 eligible inpatients received CDSS-recommended antibiotics. Receipt of antibiotics according to CDSS’s recommendations seemed to halve mortality risk of patients (OR 0.54, 95% CI 0.26–1.10, P = 0.09). Patients aged ≤65 years had greater mortality benefit (OR 0.45, 95% CI 0.20–1.00, P = 0.05) than patients that were older than 65 (OR 1.28, 95% CI 0.91–1.82, P = 0.16). No effect was observed on incidence of Clostridium difficile (OR 1.02, 95% CI 0.34–3.01), and multidrug-resistant organism (OR 1.06, 95% CI 0.42–2.71) infections. No increase in infection-related readmission (OR 1.16, 95% CI 0.48–2.79) was found in survivors. Receipt of CDSS-recommended antibiotics reduced mortality risk in patients aged 65 years or younger and did not increase the risk in older patients. Physicians should be informed of the benefits to increase their acceptance of CDSS recommendations. PMID:26617195
Colombet, Isabelle; Dart, Thierry; Leneveut, Laurence; Zunino, Sylvain; Ménard, Joël; Chatellier, Gilles
2003-01-01
Background Many preventable diseases such as ischemic heart diseases and breast cancer prevail at a large scale in the general population. Computerized decision support systems are one of the solutions for improving the quality of prevention strategies. Methods The system called EsPeR (Personalised Estimate of Risks) combines calculation of several risks with computerisation of guidelines (cardiovascular prevention, screening for breast cancer, colorectal cancer, uterine cervix cancer, and prostate cancer, diagnosis of depression and suicide risk). We present a qualitative evaluation of its ergonomics, as well as it's understanding and acceptance by a group of general practitioners. We organised four focus groups each including 6–11 general practitioners. Physicians worked on several structured clinical scenari os with the help of EsPeR, and three senior investigators leaded structured discussion sessions. Results The initial sessions identified several ergonomic flaws of the system that were easily corrected. Both clinical scenarios and discussion sessions identified several problems related to the insufficient comprehension (expression of risks, definition of familial history of disease), and difficulty for the physicians to accept some of the recommendations. Conclusion Educational, socio-professional and organisational components (i.e. time constraints for training and use of the EsPeR system during consultation) as well as acceptance of evidence-based decision-making should be taken into account before launching computerised decision support systems, or their application in randomised trials. PMID:14641924
Mortality Benefits of Antibiotic Computerised Decision Support System: Modifying Effects of Age
NASA Astrophysics Data System (ADS)
Chow, Angela L. P.; Lye, David C.; Arah, Onyebuchi A.
2015-11-01
Antibiotic computerised decision support systems (CDSSs) are shown to improve antibiotic prescribing, but evidence of beneficial patient outcomes is limited. We conducted a prospective cohort study in a 1500-bed tertiary-care hospital in Singapore, to evaluate the effectiveness of the hospital’s antibiotic CDSS on patients’ clinical outcomes, and the modification of these effects by patient factors. To account for clustering, we used multilevel logistic regression models. One-quarter of 1886 eligible inpatients received CDSS-recommended antibiotics. Receipt of antibiotics according to CDSS’s recommendations seemed to halve mortality risk of patients (OR 0.54, 95% CI 0.26-1.10, P = 0.09). Patients aged ≤65 years had greater mortality benefit (OR 0.45, 95% CI 0.20-1.00, P = 0.05) than patients that were older than 65 (OR 1.28, 95% CI 0.91-1.82, P = 0.16). No effect was observed on incidence of Clostridium difficile (OR 1.02, 95% CI 0.34-3.01), and multidrug-resistant organism (OR 1.06, 95% CI 0.42-2.71) infections. No increase in infection-related readmission (OR 1.16, 95% CI 0.48-2.79) was found in survivors. Receipt of CDSS-recommended antibiotics reduced mortality risk in patients aged 65 years or younger and did not increase the risk in older patients. Physicians should be informed of the benefits to increase their acceptance of CDSS recommendations.
NASA Astrophysics Data System (ADS)
Babakhani, Banafsheh
The aim of this thesis work was to synthesize Mn-based oxide electrodes with high surface area structures by anodic electrodeposition for application as electrochemical capacitors. Rod-like structures provide large surface areas leading to high specific capacitances. Since templated electrosynthesis of rods is not easy to use in practical applications, it is more desirable to form rod-like structures without using any templates. In this work, Mn oxide electrodes with rod-like structures (˜1.5 µm in diameter) were synthesized from a solution of 0.01 M Mn acetate under galvanostatic control without any templates, on Au coated Si substrates. The electrochemical properties of the synthesized nanocrystalline electrodes were investigated to determine the effect of morphology, chemistry and crystal structure on the corresponding electrochemical behavior of Mn oxide electrodes. Mn oxides prepared at different current densities showed a defective antifluoritetype crystal structure. The rod-like Mn oxide electrodes synthesized at low current densities (5 mAcm.2) exhibited a high specific capacitance due to their large surface areas. Also, specific capacity retention after 250 cycles in an aqueous solution of 0.5 M Na2SO4 at 100 mVs -1 was about 78% of the initial capacity (203 Fg-1 ). To improve the electrochemical capacitive behavior of Mn oxide electrodes, a sequential approach and a one-step method were adopted to synthesize Mn oxide/PEDOT electrodes through anodic deposition on Au coated Si substrates from aqueous solutions. In the former case, free standing Mn oxide rods (about 10 µm long and less than 1.5 µm in diameter) were first synthesized, then coated by electro-polymerization of a conducting polymer (PEDOT) giving coaxial rods. The one-step, co-electrodeposition method produced agglomerated Mn oxide/PEDOT particles. The electrochemical behavior of the deposits depended on the morphology and crystal structure of the fabricated electrodes, which were affected by the composition and pH of the electrolyte, temperature, current density and polymer deposition time. Mn oxide/PEDOT coaxial core/shell rods consisted of MnO2 with an antifluorite-type structure coated with amorphous PEDOT. The Mn oxide/PEDOT coaxial core/shell electrodes prepared by the sequential method showed significantly better specific capacity and redox performance properties relative to both uncoated Mn oxide rods and co- electrodeposited Mn oxide/PEDOT electrodes. The best specific capacitance for Mn oxide/PEDOT rods produced sequentially was ˜295 F g-1 with ˜92% retention after 250 cycles in 0.5 M Na2SO4 at 100 mV s-1. To further improve the electrochemical capacitive behavior of Mn oxide electrodes, Co-doped and Fe-doped Mn oxide electrodes with a rod-like morphology and antifluorite-type crystal structure were synthesized by anodic electrodeposition, on Au coated Si substrates, from dilute solutions of Mn acetate and Co sulphate and Mn acetate and Fe chloride. Also, Mn-Co oxide/PEDOT coaxial core/shell rods were synthesized by applying a shell of PEDOT on Mn-Co oxide electrodes. Mn-Co oxide/PEDOT electrodes consisted of MnO2, with partial Co 2+ and Co3+ ion substitution for Mn4+, and amorphous PEDOT. Mn-Fe oxide electrodes consisted of MnO2, with partial Fe2+ and Fe3+ ion substitution for Mn4+. Electrochemical analysis showed that the capacitance values for all deposits increased with increasing scan rate to 100 mVs -1, and then decreased after 100 mVs-1. The Mn-Co oxide/PEDOT electrodes showed improved specific capacity and electrochemical cyclability relative to uncoated Mn-Co oxides and Mn-Fe oxides. Mn-Co oxide/PEDOT electrodes with rod-like structures had high capacitances (up to 310 Fg -1) at a scan rate of 100 mVs-1 and maintained their capacitance after 500 cycles in 0.5 M Na2SO4 (91% retention). Capacitance reduction for the deposits was mainly due to the loss of Mn ions by dissolution in the electrolyte solution. To better understand the nucleation and growth mechanisms of Mn oxide electrodes, the effects of supersaturation ratio on the morphology and crystal structure of electrodeposited Mn oxide were studied. By changing deposition parameters, including deposition current density, electrolyte composition, pH and temperature, a series of nanocrystalline Mn oxide electrodes with various morphologies (continuous coatings, rod-like structures, aggregated rods and thin sheets) and an antifluorite-type crystal structure was obtained. Mn oxide thin sheets showed instantaneous nucleation and single crystalline growth; rods had a mix of instantaneous/progressive nucleation and polycrystalline growth and continuous coatings formed by progressive nucleation and polycrystalline growth. Electrochemical analysis revealed the best capacitance behaviour obtained for Mn oxide thin sheets followed by Mn oxide rods, with dimensions on the microscale, and then continuous coatings. The highest specific capacitance (˜230 Fg-1) and capacitance retention rates (˜88%) were obtained for Mn oxide thin sheets after 250 cycles in 0.5 M Na2 SO4 at 20 mVs-1.
Successful Gene Therapy in the RPGRIP1-deficient Dog: a Large Model of Cone–Rod Dystrophy
Lhériteau, Elsa; Petit, Lolita; Weber, Michel; Le Meur, Guylène; Deschamps, Jack-Yves; Libeau, Lyse; Mendes-Madeira, Alexandra; Guihal, Caroline; François, Achille; Guyon, Richard; Provost, Nathalie; Lemoine, Françoise; Papal, Samantha; El-Amraoui, Aziz; Colle, Marie-Anne; Moullier, Philippe; Rolling, Fabienne
2014-01-01
For the development of new therapies, proof-of-concept studies in large animal models that share clinical features with their human counterparts represent a pivotal step. For inherited retinal dystrophies primarily involving photoreceptor cells, the efficacy of gene therapy has been demonstrated in canine models of stationary cone dystrophies and progressive rod–cone dystrophies but not in large models of progressive cone–rod dystrophies, another important cause of blindness. To address the last issue, we evaluated gene therapy in the retinitis pigmentosa GTPase regulator interacting protein 1 (RPGRIP1)-deficient dog, a model exhibiting a severe cone–rod dystrophy similar to that seen in humans. Subretinal injection of AAV5 (n = 5) or AAV8 (n = 2) encoding the canine Rpgrip1 improved photoreceptor survival in transduced areas of treated retinas. Cone function was significantly and stably rescued in all treated eyes (18–72% of those recorded in normal eyes) up to 24 months postinjection. Rod function was also preserved (22–29% of baseline function) in four of the five treated dogs up to 24 months postinjection. No detectable rod function remained in untreated contralateral eyes. More importantly, treatment preserved bright- and dim-light vision. Efficacy of gene therapy in this large animal model of cone–rod dystrophy provides great promise for human treatment. PMID:24091916
NASA Technical Reports Server (NTRS)
Marcum, Jeremy W.; Ferkul, Paul V.; Olson, Sandra L.
2017-01-01
Normal gravity flame blowoff limits in an axisymmetric pmma rod geometry in upward axial stagnation flow are compared with microgravity Burning and Suppression of Solids II (BASS-II) results recently obtained aboard the International Space Station. This testing utilized the same BASS-II concurrent rod geometry, but with the addition of normal gravity buoyant flow. Cast polymethylmethacrylate (pmma) rods of diameters ranging from 0.635 cm to 3.81 cm were burned at oxygen concentrations ranging from 14 to 18 by volume. The forced flow velocity where blowoff occurred was determined for each rod size and oxygen concentration. These blowoff limits compare favorably with the BASS-II results when the buoyant stretch is included and the flow is corrected by considering the blockage factor of the fuel. From these results, the normal gravity blowoff boundary for this axisymmetric rod geometry is determined to be linear, with oxygen concentration directly proportional to flow speed. We describe a new normal gravity upward flame spread test method which extrapolates the linear blowoff boundary to the zero stretch limit to resolve microgravity flammability limits, something current methods cannot do. This new test method can improve spacecraft fire safety for future exploration missions by providing a tractable way to obtain good estimates of material flammability in low gravity.
Tellegen, Anna R; Willems, Nicole; Tryfonidou, Marianna A; Meij, Björn P
2015-12-07
Degenerative lumbosacral stenosis is a common problem in large breed dogs. For severe degenerative lumbosacral stenosis, conservative treatment is often not effective and surgical intervention remains as the last treatment option. The objective of this retrospective study was to assess the middle to long term outcome of treatment of severe degenerative lumbosacral stenosis with pedicle screw-rod fixation with or without evidence of radiological discospondylitis. Twelve client-owned dogs with severe degenerative lumbosacral stenosis underwent pedicle screw-rod fixation of the lumbosacral junction. During long term follow-up, dogs were monitored by clinical evaluation, diagnostic imaging, force plate analysis, and by using questionnaires to owners. Clinical evaluation, force plate data, and responses to questionnaires completed by the owners showed resolution (n = 8) or improvement (n = 4) of clinical signs after pedicle screw-rod fixation in 12 dogs. There were no implant failures, however, no interbody vertebral bone fusion of the lumbosacral junction was observed in the follow-up period. Four dogs developed mild recurrent low back pain that could easily be controlled by pain medication and an altered exercise regime. Pedicle screw-rod fixation offers a surgical treatment option for large breed dogs with severe degenerative lumbosacral stenosis with or without evidence of radiological discospondylitis in which no other treatment is available. Pedicle screw-rod fixation alone does not result in interbody vertebral bone fusion between L7 and S1.
NASA Astrophysics Data System (ADS)
Wang, Chunying; Sun, Enwei; Liu, Yingchun; Zhang, Rui; Yang, Bin; Cao, Wenwu
2016-09-01
Interface stresses strongly influence the functional property of 1-3 piezoelectric composites. Using the translucent nature of (1 - x)Pb(Mg1/3Nb2/3)O3-xPbTiO3 single crystals, we have studied stress distributions and domain configuration changes during poling inside the crystal rods by polarizing light microscopy and piezoresponse force microscopy. It was found that the interface stresses due to interaction with polymeric filler led a deformed rhombohedral phase and caused incomplete poling near rod-edges. Compared with "hard" epoxy (Epotek301) filler, "soft" epoxy (Stycast) filler showed weaker impact on the crystals rods and less influence on domain configurations. We also show that high temperature poling (70 °C) can substantially improve the piezoelectric coefficient of composites filled with hard epoxy due to creeping above the glass transition Tg. Analytic stress distribution equations based on cylinder rods were modified to explain the physical principle and to predict the stress distribution for square rods case, which was verified by finite element simulation to be accurate within 5%.
Restoration of vision after transplantation of photoreceptors.
Pearson, R A; Barber, A C; Rizzi, M; Hippert, C; Xue, T; West, E L; Duran, Y; Smith, A J; Chuang, J Z; Azam, S A; Luhmann, U F O; Benucci, A; Sung, C H; Bainbridge, J W; Carandini, M; Yau, K-W; Sowden, J C; Ali, R R
2012-05-03
Cell transplantation is a potential strategy for treating blindness caused by the loss of photoreceptors. Although transplanted rod-precursor cells are able to migrate into the adult retina and differentiate to acquire the specialized morphological features of mature photoreceptor cells, the fundamental question remains whether transplantation of photoreceptor cells can actually improve vision. Here we provide evidence of functional rod-mediated vision after photoreceptor transplantation in adult Gnat1−/− mice, which lack rod function and are a model of congenital stationary night blindness. We show that transplanted rod precursors form classic triad synaptic connections with second-order bipolar and horizontal cells in the recipient retina. The newly integrated photoreceptor cells are light-responsive with dim-flash kinetics similar to adult wild-type photoreceptors. By using intrinsic imaging under scotopic conditions we demonstrate that visual signals generated by transplanted rods are projected to higher visual areas, including V1. Moreover, these cells are capable of driving optokinetic head tracking and visually guided behaviour in the Gnat1−/− mouse under scotopic conditions. Together, these results demonstrate the feasibility of photoreceptor transplantation as a therapeutic strategy for restoring vision after retinal degeneration.
Guiding and amplification properties of rod-type photonic crystal fibers with sectioned core doping
NASA Astrophysics Data System (ADS)
Selleri, S.; Poli, F.; Passaro, D.; Cucinotta, A.; Lægsgaard, J.; Broeng, J.
2009-05-01
Rod-type photonic crystal fibers are large mode area double-cladding fibers with an outer diameter of few millimeters which can provide important advantages for high-power lasers and amplifiers. Numerical studies have recently demonstrated the guidance of higher-order modes in these fibers, which can worsen the output beam quality of lasers and amplifiers. In the present analysis a sectioned core doping has been proposed for Ybdoped rod-type photonic crystal fibers, with the aim to improve the higher-order mode suppression. A full-vector modal solver based on the finite element method has been applied to properly design the low refractive index ring in the fiber core, which can provide an increase of the differential overlap between the fundamental and the higher-order mode. Then, the gain competition among the guided modes along the Yb-doped rod-type fibers has been investigated with a spatial and spectral amplifier model. Simulation results have shown the effectiveness of the sectioned core doping in worsening the higher-order mode overlap on the doped area, thus providing an effective single-mode behavior of the Yb-doped rod-type photonic crystal fibers.
Installation, high-power conditioning and beam commissioning of the upgraded SARAF 4-rods RFQ
NASA Astrophysics Data System (ADS)
Weissman, L.; Perry, A.; Bechtold, A.; Berkovits, D.; Kaizer, B.; Luner, Y.; Niewieczerzal, P.; Rodnizki, J.; Silverman, I.; Shor, A.; Nusbaum, D.
2018-05-01
The original SARAF 3.8 m long 4-rod Radio Frequency Quadrupole (RFQ) has been successful in acceleration of 4 mA Continuous Wave (CW) proton beam and pulsed deuteron beam to 1.5 MeV/u. However, conditions for running CW deuteron beam have not been achieved in the original design. A new 4-rod structure has been designed and implemented, with the goal of reducing the RF power required for CW deuteron operation while slightly compromising the RFQ exit energy to 1.27 MeV/u. The new 4-rod structure was manufactured, and installed in place of the old rod electrodes. Superior field homogeneity was achieved. The RFQ was successfully conditioned to the RF power 200 kW required for CW deuteron operation, with sufficient power margin. The commissioning with proton and deuteron beams showed that most of beam parameters are close to the designed specifications. The first operation with CW RF power of 5 mA deuteron beam was demonstrated. In addition, a 1.1 mA CW deuteron beam was transported through the superconducting module. The future scope of RFQ improvements is discussed.
Wang, Jingfeng; Jiang, Weiyan; Li, Yang; Ma, Yao
2018-01-01
The morphology evolution of long-period stacking ordered (LPSO) phases on corrosion behavior of Mg95.33Zn2Y2.67 alloy is investigated systematically during as-cast, pre-extrusion heat-treated, as-extruded and post-extrusion heat-treated conditions. The second phases in the as-cast alloy are only LPSO phases with a few Y particles. The pre-extrusion heat treatment changed LPSO phases from blocks into a rudimentary rod shape with lamellar structure, subsequently into fine fragments by extrusion, and then into a regular rod shape with lamellar structure followed by post-extrusion heat treatment. Immersion tests and electrochemical measurements in 3.5 wt % NaCl solution reveal that the post-extrusion heat-treated alloy has the best corrosion resistance with the lowest corrosion rate. This is attributed to the rod-shaped LPSO phases, which could hinder corrosion proceeding, and result in corrosion orientated along the direction of rods and forming relatively dense long-strip corrosion products. Our findings demonstrate that the improved corrosion resistance of magnesium alloys with LPSO phases can be tailored effectively by the proceeding technology and post-heat treatment. PMID:29772721
Martin, P; Brown, M C; Espin-Garcia, O; Cuffe, S; Pringle, D; Mahler, M; Villeneuve, J; Niu, C; Charow, R; Lam, C; Shani, R M; Hon, H; Otsuka, M; Xu, W; Alibhai, S; Jenkinson, J; Liu, G
2016-03-01
In this study, we compared cancer patients preference for computerised (tablet/web-based) surveys versus paper. We also assessed whether the understanding of a cancer-related topic, pharmacogenomics is affected by the survey format, and examined differences in demographic and medical characteristics which may affect patient preference and understanding. Three hundred and four cancer patients completed a tablet-administered survey and another 153 patients completed a paper-based survey. Patients who participated in the tablet survey were questioned regarding their preference for survey format administration (paper, tablet and web-based). Understanding was assessed with a 'direct' method, by asking patients to assess their understanding of genetic testing, and with a 'composite' score. Patients preferred administration with tablet (71%) compared with web-based (12%) and paper (17%). Patients <65 years old, non-Caucasians and white-collar professionals significantly preferred the computerised format following multivariate analysis. There was no significant difference in understanding between the paper and tablet survey with direct questioning or composite score. Age (<65 years) and white-collar professionals were associated with increased understanding (both P = 0.03). There was no significant difference in understanding between the tablet and print survey in a multivariate analysis. Patients overwhelmingly preferred computerised surveys and understanding of pharmacogenomics was not affected by survey format. © 2015 John Wiley & Sons Ltd.
Software for computerised analysis of cardiotocographic traces.
Romano, M; Bifulco, P; Ruffo, M; Improta, G; Clemente, F; Cesarelli, M
2016-02-01
Despite the widespread use of cardiotocography in foetal monitoring, the evaluation of foetal status suffers from a considerable inter and intra-observer variability. In order to overcome the main limitations of visual cardiotocographic assessment, computerised methods to analyse cardiotocographic recordings have been recently developed. In this study, a new software for automated analysis of foetal heart rate is presented. It allows an automatic procedure for measuring the most relevant parameters derivable from cardiotocographic traces. Simulated and real cardiotocographic traces were analysed to test software reliability. In artificial traces, we simulated a set number of events (accelerations, decelerations and contractions) to be recognised. In the case of real signals, instead, results of the computerised analysis were compared with the visual assessment performed by 18 expert clinicians and three performance indexes were computed to gain information about performances of the proposed software. The software showed preliminary performance we judged satisfactory in that the results matched completely the requirements, as proved by tests on artificial signals in which all simulated events were detected from the software. Performance indexes computed in comparison with obstetricians' evaluations are, on the contrary, not so satisfactory; in fact they led to obtain the following values of the statistical parameters: sensitivity equal to 93%, positive predictive value equal to 82% and accuracy equal to 77%. Very probably this arises from the high variability of trace annotation carried out by clinicians. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Gilbert, Louisa; Shaw, Stacey A; Goddard-Eckrich, Dawn; Chang, Mingway; Rowe, Jessica; McCrimmon, Tara; Almonte, Maria; Goodwin, Sharun; Epperson, Matthew
2015-12-10
The high rate of intimate partner violence (IPV) victimisation found among substance-using women receiving community supervision underscores the need for effective IPV victimisation screening, brief intervention and referral to treatment services (SBIRT) for this population. This randomised controlled trial (RCT) aims to assess the feasibility, safety and efficacy of a single-session computerised self-paced IPV SBIRT (Computerised WINGS) in identifying IPV victimisation among women under community supervision and increasing access to IPV services, compared to the same IPV SBIRT service delivered by a case manager (Case Manager WINGS). This RCT was conducted with 191 substance-using women in probation and community court sites in New York City. No significant differences were found between Computerised and Case Manager WINGS arms on any outcomes. Both arms reported identical high rates of any physical, sexual or psychological IPV victimisation in the past year (77% for both arms) during the intervention. Both arms experienced significant increases from baseline to the 3-month follow-up in receipt of IPV services, social support, IPV self-efficacy and abstinence from drug use. Findings suggest that both modalities of WINGS show promise in identifying and addressing IPV victimisation among substance-using women receiving community supervision. Copyright © 2015 John Wiley & Sons, Ltd.
Rasch-built Overall Disability Scale (R-ODS) for immune-mediated peripheral neuropathies.
van Nes, S I; Vanhoutte, E K; van Doorn, P A; Hermans, M; Bakkers, M; Kuitwaard, K; Faber, C G; Merkies, I S J
2011-01-25
To develop a patient-based, linearly weighted scale that captures activity and social participation limitations in patients with Guillain-Barré syndrome (GBS), chronic inflammatory demyelinating polyradiculoneuropathy (CIDP), and gammopathy-related polyneuropathy (MGUSP). A preliminary Rasch-built Overall Disability Scale (R-ODS) containing 146 activity and participation items was constructed, based on the WHO International Classification of Functioning, Disability and Health, literature search, and patient interviews. The preliminary R-ODS was assessed twice (interval: 2-4 weeks; test-retest reliability studies) in 294 patients who experienced GBS in the past (n = 174) or currently have stable CIDP (n = 80) or MGUSP (n = 40). Data were analyzed using the Rasch unidimensional measurement model (RUMM2020). The preliminary R-ODS did not meet the Rasch model expectations. Based on disordered thresholds, misfit statistics, item bias, and local dependency, items were systematically removed to improve the model fit, regularly controlling the class intervals and model statistics. Finally, we succeeded in constructing a 24-item scale that fulfilled all Rasch requirements. "Reading a newspaper/book" and "eating" were the 2 easiest items; "standing for hours" and "running" were the most difficult ones. Good validity and reliability were obtained. The R-ODS is a linearly weighted scale that specifically captures activity and social participation limitations in patients with GBS, CIDP, and MGUSP. Compared to the Overall Disability Sum Score, the R-ODS represents a wider range of item difficulties, thereby better targeting patients with different ability levels. If responsive, the R-ODS will be valuable for future clinical trials and follow-up studies in these conditions.
Harris, Elizabeth; Macpherson, Helen; Pipingas, Andrew
2015-01-01
Supplementation with vitamins, minerals and phytonutrients may be beneficial for cognition, especially in older adults. The aim of this study was to assess the effects of multivitamin supplementation in older adults on cognitive function and associated blood biomarkers. In a randomised, double blind, placebo-controlled trial, healthy women (n = 68) and men (n = 48) aged 55–65 years were supplemented daily for 16 weeks with women’s and men’s formula multivitamin supplements. Assessments at baseline and post-supplementation included computerised cognitive tasks and blood biomarkers relevant to cognitive aging. No cognitive improvements were observed after supplementation with either formula; however, several significant improvements were observed in blood biomarkers including increased levels of vitamins B6 and B12 in women and men; reduced C-reactive protein in women; reduced homocysteine and marginally reduced oxidative stress in men; as well as improvements to the lipid profile in men. In healthy older people, multivitamin supplementation improved a number of blood biomarkers that are relevant to cognition, but these biomarker changes were not accompanied by improved cognitive function. PMID:25996285
Spatial disorientation in right-hemisphere infarction: a study of the speed of recovery.
Meerwaldt, J D
1983-01-01
Sixteen patients with an infarct in the posterior region of the right hemisphere were tested at fixed intervals after a stroke (2 weeks, 6 weeks, 3 months, 6 months, 1 year) with the rod orientation test and the line orientation test. All patients initially showed spatial disorientation on the rod orientation test, while only three had a defective performance on the line orientation test. The recovery on the rod orientation test was parallel with the neurological improvement. Recovery mainly took place in the first six months after the stroke. Most patients then performed at a normal level. A relation between the size of the lesion (assessed from CT scans) and the speed of recovery was found. PMID:6101178
One-dimensional nanoferroic rods; synthesis and characterization
NASA Astrophysics Data System (ADS)
Ahmed, M. A.; Seddik, U.; Okasha, N.; Imam, N. G.
2015-11-01
One-dimensional nanoferroic rods of BaTiO3 were synthesized by improved citrate auto-combustion technology using tetrabutyl titanate. X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray (EDX), transmission electron microscopy (TEM), atomic force microscopy (AFM) and Fourier transform infrared spectroscopy (FTIR) have been used to characterize the prepared sample. The results indicated that the crystal structure of BaTiO3 is tetragonal phase with an average crystallite size of 47 nm. SEM image gives a cauliflower-like morphology of the agglomerated nanorods. The stoichiometry of the chemical composition of the BaTiO3 ceramic was confirmed by EDX. TEM micrograph exhibited that BaTiO3 nanoparticles have rod-like shape with an average length of 120 nm and width of 43 nm. AFM was used to investigate the surface topography and its roughness. The topography image in 3D showed that the BaTiO3 particles have a rod shape with an average particle size of 116 nm which in agreement with 3D TEM result.
Laser rods with undoped, flanged end-caps for end-pumped laser applications
Meissner, H.E.; Beach, R.J.; Bibeau, C.; Sutton, S.B.; Mitchell, S.; Bass, I.; Honea, E.
1999-08-10
A method and apparatus for achieving improved performance in a solid state laser is provided. A flanged, at least partially undoped end-cap is attached to at least one end of a laserable medium. Preferably flanged, undoped end-caps are attached to both ends of the laserable medium. Due to the low scatter requirements for the interface between the end-caps and the laser rod, a non-adhesive method of bonding is utilized such as optical contacting combined with a subsequent heat treatment of the optically contacted composite. The non-bonded end surfaces of the flanged end-caps are coated with laser cavity coatings appropriate for the lasing wavelength of the laser rod. A cooling jacket, sealably coupled to the flanged end-caps, surrounds the entire length of the laserable medium. Radiation from a pump source is focused by a lens duct and passed through at least one flanged end-cap into the laser rod. 14 figs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frankhouser, W.L.; Eyler, J.H.
1956-07-24
Five reference fuel rod bundles were welded and evaluated dimensionally. Dimensional data are presented for the as-welded condition and for the annealed bundle with spacer strips removed (prior to the final machining operations). The welding sequence developed for Core Manufacturing should provide A'' boundles in respect to rod spacing measurements. It will probably not be possible to meet the same requirements for water channel averages, because the design tolerances are not consistent with some factors inherent to the production process. A method to improve this situation is presented. The data presented were evaluated in a fashion similar to that whichmore » would be used in the proposed scheme. Rods tended to bow resulting in a slightly barrel-shaped'' boundle. It is believed this condition can be overcome by providing special bundle peripheral clamps during annealing. Rod distortion should also be reduced by a redesign and relocation of strip spacers. The new design is proposed. (auth)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hernandez, M. R.; Gamboa-deBuen, I.; Dies, P.
Computerised tomography (CT) is a favourite method of medical diagnosis. Its use has thus increased rapidly throughout the world, particularly in studies relating to children. However to avoid administering unnecessarily high doses of radiation to paediatric patients it is important to have correct dose reference levels to minimize risk. The research is being developed within the public health sector at the Hospital Infantil de Mexico 'Dr. Federico Gomez.' We measured the entrance surface air kerma (K{sub P}) in paediatric patients, during the radiological studies of control in CT (studies of head, thorax and abdomen). Phantom was used to evaluate imagemore » quality as the tomograph requires a high resolution image in order to operate at its optimum level.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aadila, A., E-mail: aadilaazizali@gmail.com; Asib, N. A. M.; Afaah, A. N.
In this work, solution-immersion method was used to grow ZnO rods on PMMA-coated substrate. For this purpose, 0.15 M of zinc nitrate hexahydrate (Zn(NO{sub 3}){sub 2}.6H{sub 2}O) and hexamethylenetetramine (C{sub 6}H{sub 12}N{sub 4}) were used to growth of ZnO films at different annealing temperatures (room temperature, 80, 100, 120 and 140 °C). The morphology of the films was investigated by Scanning Electron Microscope (SEM) and optical properties were studied by Ultraviolet (UV-Vis) Spectroscopy. SEM analysis showed ubiquitous growth of ZnO rods that became better aligned and more closely-packed as the annealing temperature increased. As the annealing temperature exceeds 100 °C,more » the rods tend to merge to adjacent particles and the UV absorption decreased for the sample at higher temperatures (120 °C and 140 °C). Good absorption and better orientation of ZnO was obtained for the sample annealed at 100 °C due to the film possess better distribution and these improved orientation of particles caused the light to be effectively scattered on the sample. Both surface morphology and UV was significantly affected by the change in annealing temperatures thus thermal effect played a dominant role in shaping and improving the orientation of ZnO rods on PMMA-coated and its UV absorption.« less
Littlewood, Elizabeth; Hewitt, Catherine; Brierley, Gwen; Tharmanathan, Puvan; Araya, Ricardo; Barkham, Michael; Bower, Peter; Cooper, Cindy; Gask, Linda; Kessler, David; Lester, Helen; Lovell, Karina; Parry, Glenys; Richards, David A; Andersen, Phil; Brabyn, Sally; Knowles, Sarah; Shepherd, Charles; Tallon, Debbie; White, David
2015-01-01
Study question How effective is supported computerised cognitive behaviour therapy (cCBT) as an adjunct to usual primary care for adults with depression? Methods This was a pragmatic, multicentre, three arm, parallel randomised controlled trial with simple randomisation. Treatment allocation was not blinded. Participants were adults with symptoms of depression (score ≥10 on nine item patient health questionnaire, PHQ-9) who were randomised to receive a commercially produced cCBT programme (“Beating the Blues”) or a free to use cCBT programme (MoodGYM) in addition to usual GP care. Participants were supported and encouraged to complete the programme via weekly telephone calls. Control participants were offered usual GP care, with no constraints on the range of treatments that could be accessed. The primary outcome was severity of depression assessed with the PHQ-9 at four months. Secondary outcomes included health related quality of life (measured by SF-36) and psychological wellbeing (measured by CORE-OM) at four, 12, and 24 months and depression at 12 and 24 months. Study answer and limitations Participants offered commercial or free to use cCBT experienced no additional improvement in depression compared with usual GP care at four months (odds ratio 1.19 (95% confidence interval 0.75 to 1.88) for Beating the Blues v usual GP care; 0.98 (0.62 to 1.56) for MoodGYM v usual GP care). There was no evidence of an overall difference between either programme compared with usual GP care (0.99 (0.57 to 1.70) and 0.68 (0.42 to 1.10), respectively) at any time point. Commercially provided cCBT conferred no additional benefit over free to use cCBT or usual GP care at any follow-up point. Uptake and use of cCBT was low, despite regular telephone support. Nearly a quarter of participants (24%) had dropped out by four months. The study did not have enough power to detect small differences so these cannot be ruled out. Findings cannot be generalised to cCBT offered with a much higher level of guidance and support. What this study adds Supported cCBT does not substantially improve depression outcomes compared with usual GP care alone. In this study, neither a commercially available nor free to use computerised CBT intervention was superior to usual GP care. Funding, competing interests, data sharing Commissioned and funded by the UK National Institute for Health Research (NIHR) Health Technology Assessment (HTA) programme (project No 06/43/05). The authors have no competing interests. Requests for patient level data will be considered by the REEACT trial management group Trial registration Current Controlled Trials ISRCTN91947481. PMID:26559241
2017-04-29
Continuous electronic fetal heart-rate monitoring is widely used during labour, and computerised interpretation could increase its usefulness. We aimed to establish whether the addition of decision-support software to assist in the interpretation of cardiotocographs affected the number of poor neonatal outcomes. In this unmasked randomised controlled trial, we recruited women in labour aged 16 years or older having continuous electronic fetal monitoring, with a singleton or twin pregnancy, and at 35 weeks' gestation or more at 24 maternity units in the UK and Ireland. They were randomly assigned (1:1) to decision support with the INFANT system or no decision support via a computer-generated stratified block randomisation schedule. The primary outcomes were poor neonatal outcome (intrapartum stillbirth or early neonatal death excluding lethal congenital anomalies, or neonatal encephalopathy, admission to the neonatal unit within 24 h for ≥48 h with evidence of feeding difficulties, respiratory illness, or encephalopathy with evidence of compromise at birth), and developmental assessment at age 2 years in a subset of surviving children. Analyses were done by intention to treat. This trial is completed and is registered with the ISRCTN Registry, number 98680152. Between Jan 6, 2010, and Aug 31, 2013, 47 062 women were randomly assigned (23 515 in the decision-support group and 23 547 in the no-decision-support group) and 46 042 were analysed (22 987 in the decision-support group and 23 055 in the no-decision-support group). We noted no difference in the incidence of poor neonatal outcome between the groups-172 (0·7%) babies in the decision-support group compared with 171 (0·7%) babies in the no-decision-support group (adjusted risk ratio 1·01, 95% CI 0·82-1·25). At 2 years, no significant differences were noted in terms of developmental assessment. Use of computerised interpretation of cardiotocographs in women who have continuous electronic fetal monitoring in labour does not improve clinical outcomes for mothers or babies. National Institute for Health Research. Copyright © 2017 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.
Gums induced microstructure stability in Ca(II)-alginate beads containing lactase analyzed by SAXS.
Traffano-Schiffo, Maria Victoria; Castro-Giraldez, Marta; Fito, Pedro J; Perullini, Mercedes; Santagapita, Patricio R
2018-01-01
Previous works show that the addition of trehalose and gums in β-galactosidase (lactase) Ca(II)-alginate encapsulation systems improved its intrinsic stability against freezing and dehydration processes in the pristine state. However, there is no available information on the evolution in microstructure due to the constraints imposed by the operational conditions. The aim of this research is to study the time course of microstructural changes of Ca(II)-alginate matrices driven by the presence of trehalose, arabic and guar gums as excipients and to discuss how these changes influence the diffusional transport (assessed by LF-NMR) and the enzymatic activity of the encapsulated lactase. The structural modifications at different scales were assessed by SAXS. The incorporation of gums as second excipients induces a significant stabilization in the microstructure not only at the rod scale, but also in the characteristic size and density of alginate dimers (basic units of construction of rods) and the degree of interconnection of rods at a larger scale, improving the performance in terms of lactase activity. Copyright © 2017 Elsevier Ltd. All rights reserved.
Development of burnup dependent fuel rod model in COBRA-TF
NASA Astrophysics Data System (ADS)
Yilmaz, Mine Ozdemir
The purpose of this research was to develop a burnup dependent fuel thermal conductivity model within Pennsylvania State University, Reactor Dynamics and Fuel Management Group (RDFMG) version of the subchannel thermal-hydraulics code COBRA-TF (CTF). The model takes into account first, the degradation of fuel thermal conductivity with high burnup; and second, the fuel thermal conductivity dependence on the Gadolinium content for both UO2 and MOX fuel rods. The modified Nuclear Fuel Industries (NFI) model for UO2 fuel rods and Duriez/Modified NFI Model for MOX fuel rods were incorporated into CTF and fuel centerline predictions were compared against Halden experimental test data and FRAPCON-3.4 predictions to validate the burnup dependent fuel thermal conductivity model in CTF. Experimental test cases from Halden reactor fuel rods for UO2 fuel rods at Beginning of Life (BOL), through lifetime without Gd2O3 and through lifetime with Gd 2O3 and a MOX fuel rod were simulated with CTF. Since test fuel rod and FRAPCON-3.4 results were based on single rod measurements, CTF was run for a single fuel rod surrounded with a single channel configuration. Input decks for CTF were developed for one fuel rod located at the center of a subchannel (rod-centered subchannel approach). Fuel centerline temperatures predicted by CTF were compared against the measurements from Halden experimental test data and the predictions from FRAPCON-3.4. After implementing the new fuel thermal conductivity model in CTF and validating the model with experimental data, CTF model was applied to steady state and transient calculations. 4x4 PWR fuel bundle configuration from Purdue MOX benchmark was used to apply the new model for steady state and transient calculations. First, one of each high burnup UO2 and MOX fuel rods from 4x4 matrix were selected to carry out single fuel rod calculations and fuel centerline temperatures predicted by CTF/TORT-TD were compared against CTF /TORT-TD /FRAPTRAN predictions. After confirming that the new fuel thermal conductivity model in CTF worked and provided consistent results with FRAPTRAN predictions for a single fuel rod configuration, the same type of analysis was carried out for a bigger system which is the 4x4 PWR bundle consisting of 15 fuel pins and one control guide tube. Steady- state calculations at Hot Full Power (HFP) conditions for control guide tube out (unrodded) were performed using the 4x4 PWR array with CTF/TORT-TD coupled code system. Fuel centerline, surface and average temperatures predicted by CTF/TORT-TD with and without the new fuel thermal conductivity model were compared against CTF/TORT-TD/FRAPTRAN predictions to demonstrate the improvement in fuel centerline predictions when new model was used. In addition to that constant and CTF dynamic gap conductance model were used with the new thermal conductivity model to show the performance of the CTF dynamic gap conductance model and its impact on fuel centerline and surface temperatures. Finally, a Rod Ejection Accident (REA) scenario using the same 4x4 PWR array was run both at Hot Zero Power (HZP) and Hot Full Power (HFP) condition, starting at a position where half of the control rod is inserted. This scenario was run using CTF/TORT-TD coupled code system with and without the new fuel thermal conductivity model. The purpose of this transient analysis was to show the impact of thermal conductivity degradation (TCD) on feedback effects, specifically Doppler Reactivity Coefficient (DRC) and, eventually, total core reactivity.
Taylor, Scott M; Loew, Ellis R; Grace, Michael S
2015-01-01
Unlike the mammalian retina, the teleost fish retina undergoes persistent neurogenesis from intrinsic stem cells. In marine teleosts, most cone photoreceptor genesis occurs early in the embryonic and larval stages, and rods are added primarily during and after metamorphosis. This study demonstrates a developmental paradigm in elopomorph fishes in which retinas are rod-dominated in larvae, but undergo periods of later cone genesis. Retinal characteristics were compared at different developmental stages among three ecologically distinct elopomorph fishes-ladyfish (Elops saurus), bonefish (Albula vulpes), and speckled worm eel (Myrophis punctatus). The objectives were to improve our understanding of (1) the developmental strategy in the elopomorph retina, (2) the functional architecture of the retina as it relates to ecology, and (3) how the light environment influences photoreceptor genesis. Photoreceptor morphologies, distributions, and spectral absorption were studied at larval, juvenile, and adult stages. Premetamorphic retinas in all three species are rod-dominated, but the retinas of these species undergo dramatic change over the course of development, resulting in juvenile and adult retinal characteristics that correlate closely with ecology. Adult E. saurus has high rod densities, grouped photoreceptors, a reflective tapetum, and longer-wavelength photopigments, supporting vision in turbid, low-light conditions. Adult A. vulpes has high cone densities, low rod densities, and shorter-wavelength photopigments, supporting diurnal vision in shallow, clear water. M. punctatus loses cones during metamorphosis, develops new cones after settlement, and maintains high rod but low cone densities, supporting primarily nocturnal vision. M. punctatus secondary cone genesis occurs rapidly throughout the retina, suggesting a novel mechanism of vertebrate photoreceptor genesis. Finally, in postsettlement M. punctatus, the continuous presence or absence of visible light modulates rod distribution but does not affect secondary cone genesis, suggesting some degree of developmental plasticity influenced by the light environment.
Bavinger, J. Clay; Dunbar, Grace E.; Stem, Maxwell S.; Blachley, Taylor S.; Kwark, Leon; Farsiu, Sina; Jackson, Gregory R.; Gardner, Thomas W.
2016-01-01
Purpose The pathophysiology of vision loss in persons with diabetic retinopathy (DR) is complex and incompletely defined. We hypothesized that retinal pigment epithelium (RPE) and rod and cone photoreceptor dysfunction, as measured by dark adaptometry, would increase with severity of DR, and that pan-retinal photocoagulation (PRP) would exacerbate this dysfunction. Methods Dark adaptation (DA) was measured in subjects with diabetes mellitus and healthy controls. Dark adaptation was measured at 5° superior to the fovea following a flash bleach, and the data were analyzed to yield cone and rod sensitivity curves. Retinal layer thicknesses were quantified using spectral-domain optical coherence tomography (OCT). Results The sample consisted of 23 controls and 73 diabetic subjects. Subjects with moderate nonproliferative diabetic retinopathy (NPDR) exhibited significant impairment of rod recovery rate compared with control subjects (P = 0.04). Cone sensitivity was impaired in subjects with proliferative diabetic retinopathy (PDR) (type 1 diabetes mellitus [T1DM]: P = 0.0047; type 2 diabetes mellitus [T2DM]: P < 0.001). Subjects with untreated PDR compared with subjects treated with PRP exhibited similar rod recovery rates and cone sensitivities. Thinner RPE as assessed by OCT was associated with slower rod recovery and lower cone sensitivity, and thinner photoreceptor inner segment/outer segment layer was associated with lower cone sensitivity. Conclusions The results suggest that RPE and photoreceptor cell dysfunction, as assessed by cone sensitivity level and rod- and RPE-mediated dark adaptation, progresses with worsening DR, and rod recovery dysfunction occurs earlier than cone dysfunction. Function was preserved following PRP. The findings suggest multiple defects in retinoid function and provide potential points to improve visual function in persons with PDR. PMID:26803796
Features of electric drive sucker rod pumps for oil production
NASA Astrophysics Data System (ADS)
Gizatullin, F. A.; Khakimyanov, M. I.; Khusainov, F. F.
2018-01-01
This article is about modes of operation of electric drives of downhole sucker rod pumps. Downhole oil production processes are very energy intensive. Oil fields contain many oil wells; many of them operate in inefficient modes with significant additional losses. Authors propose technical solutions to improve energy performance of a pump unit drives: counterweight balancing, reducing of electric motor power, replacing induction motors with permanent magnet motors, replacing balancer drives with chain drives, using of variable frequency drives.
Ballios, Brian G; Cooke, Michael J; Donaldson, Laura; Coles, Brenda L K; Morshead, Cindi M; van der Kooy, Derek; Shoichet, Molly S
2015-06-09
The utility of stem cells and their progeny in adult transplantation models has been limited by poor survival and integration. We designed an injectable and bioresorbable hydrogel blend of hyaluronan and methylcellulose (HAMC) and tested it with two cell types in two animal models, thereby gaining an understanding of its general applicability for enhanced cell distribution, survival, integration, and functional repair relative to conventional cell delivery in saline. HAMC improves cell survival and integration of retinal stem cell (RSC)-derived rods in the retina. The pro-survival mechanism of HAMC is ascribed to the interaction of the CD44 receptor with HA. Transient disruption of the retinal outer limiting membrane, combined with HAMC delivery, results in significantly improved rod survival and visual function. HAMC also improves the distribution, viability, and functional repair of neural stem and progenitor cells (NSCs). The HAMC delivery system improves cell transplantation efficacy in two CNS models, suggesting broad applicability. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Federmann, Rolf; Goldsmith, Robert; Bäckström, Martin
2007-04-01
A validation study of a computerised test recently developed involving the Stroop effect, extended here by inclusion of a third, more difficult test series, is presented. Three groups of men belonging to the Swedish armed forces and adjudged to differ in their qualifications (20, 32, and 19 men of levels 1, 2, and 3, respectively) and a fourth group of 18 men convicted of serious crimes of violence were given this test, termed the Stress Strategy Test. Discriminant analysis of the test's 12 variables (four for each of the three test series) yielded a discriminant power of 65% for the total group, highest for the level 1 group (80%) and for the nonmilitary group (72%), results substantially better than obtained for the original version of the test with use of similar subject groups.
Shanahan, Marian; Shakeshaft, Anthony; Mattick, Richard P
2006-01-01
To assess the relative cost effectiveness of four strategies (academic detailing, computerised reminder systems, target payments and interactive continuing medical education) to increase the provision of screening and brief interventions by Australian GPs with the ultimate goal of decreasing risky alcohol consumption among their patients. This project used a modelling approach to combine information on the effectiveness and costs of four separate strategies to change GP behaviours to estimate their relative cost effectiveness. The computerised reminder system and academic detailing appear most effective in achieving a decrease in the number of standard drinks consumed by risky drinkers. Regardless of the assumptions made, the targeted payment strategy appeared to be the least cost-effective method to achieve a decrease in risky alcohol consumption while the other three strategies appear reasonably comparable.
Bomba, D; de Silva, A
2001-01-01
Research into patient attitudes towards the use of technology in health care needs to be given much greater attention within health informatics. Past research has often focused more on the needs of health care providers rather than the end users. This article attempts to redress this knowledge bias by reporting on a case study of the responses gained from patients in a selected Australian medical practice towards the use of computerised medical records and unique identifiers. The responses (n=138) were gained from a survey of patients over a 13 day period of practice operation. This case study serves as an example of the type of future consumer health informatics research which can be undertaken not just in Australia but also in other countries, both at local regional levels and at a national level.
Pain Assessment–Can it be Done with a Computerised System? A Systematic Review and Meta-Analysis
Pombo, Nuno; Garcia, Nuno; Bousson, Kouamana; Spinsante, Susanna; Chorbev, Ivan
2016-01-01
Background: Mobile and web technologies are becoming increasingly used to support the treatment of chronic pain conditions. However, the subjectivity of pain perception makes its management and evaluation very difficult. Pain treatment requires a multi-dimensional approach (e.g., sensory, affective, cognitive) whence the evidence of technology effects across dimensions is lacking. This study aims to describe computerised monitoring systems and to suggest a methodology, based on statistical analysis, to evaluate their effects on pain assessment. Methods: We conducted a review of the English-language literature about computerised systems related to chronic pain complaints that included data collected via mobile devices or Internet, published since 2000 in three relevant bibliographical databases such as BioMed Central, PubMed Central and ScienceDirect. The extracted data include: objective and duration of the study, age and condition of the participants, and type of collected information (e.g., questionnaires, scales). Results: Sixty-two studies were included, encompassing 13,338 participants. A total of 50 (81%) studies related to mobile systems, and 12 (19%) related to web-based systems. Technology and pen-and-paper approaches presented equivalent outcomes related with pain intensity. Conclusions: The adoption of technology was revealed as accurate and feasible as pen-and-paper methods. The proposed assessment model based on data fusion combined with a qualitative assessment method was revealed to be suitable. Data integration raises several concerns and challenges to the design, development and application of monitoring systems applied to pain. PMID:27089351
Virtual classroom helps medical education for both Chinese and foreign students.
Shi, C; Wang, L; Li, X; Chai, S; Niu, W; Kong, Y; Zhou, W; Yin, W
2015-11-01
The rapid development of computer and internet technology has a strong influence over one's quality of education within different fields of study. To determine the potential benefits of introducing internet into medical school classes, a pilot study was conducted in three different Chinese medical schools. Seven hundred and eight medical school undergraduates, 385 dental school students and 366 foreign students were randomly recruited to complete a self-administered questionnaire. The contents included personal information, current usage of computer and internet, and attitudes towards the computerised teaching methods. Two forum groups were created using instant message software and were randomly assigned to two classes, allowing students to freely ask or discuss questions with the help of their teachers in these two virtual classrooms. All 1539 questionnaires were accepted and analysed. Although there were some differences between Chinese and foreign undergraduates, both group of students were highly proficient in internet usage and navigation. Overwhelmingly, 88.37% of the students owned a computer and frequently logged onto the internet. Most of them believed that the internet is a helpful adjunct to their studies and held positive attitudes towards computerised teaching. Compared to the classes that were not assigned internet forums, the two experimental classes performed significantly better on the examination. Our results suggest that computerised teaching methods have significant potential to assist in learning for both Chinese and foreign medical undergraduates. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
The influence of neck pain on sensorimotor function in the elderly.
Uthaikhup, Sureeporn; Jull, Gwendolen; Sungkarat, Somporn; Treleaven, Julia
2012-01-01
Greater disturbances in sensorimotor control have been demonstrated in younger to middle aged groups. However, it is unknown whether or not the impairments documented in these populations can be extrapolated to elders with neck pain. The aim of this study was to investigate the influence of neck pain on sensorimotor function in elders. Twenty elders with neck pain (12 women and 8 men) and 20 healthy elder controls (14 women and 6 men) aged 65 years and over were recruited from the general community. Tests for sensorimotor function included; cervical joint position sense (JPS); computerised rod-and-frame test (RFT); smooth pursuit neck torsion test (SPNT); standing balance (under conditions of eyes open, eyes closed on firm and soft surfaces in comfortable stance); step test and ten-meter walk test with and without head movement. Elders with neck pain had greater deficits in the majority of sensorimotor function tests after controlling for effects of age and comorbidities. Significant differences were found in the SPNT (p<0.01), error in the RFT (frame angled at 10° and 15° anticlockwise) (p<0.05), standing balance (amplitude of sway) - eyes open on a firm surface in the medio-lateral (ML) direction (p=0.03), and total number of steps on the step test, both left and right sides (p<0.01). Elders with neck pain have greater sensorimotor disturbances than elders without neck pain, supporting a contribution of altered afferent information originating from the cervical spine to such disturbances. The findings may inform falls prevention and management programs. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Samaranayake, N R; Cheung, S T D; Cheng, K; Lai, K; Chui, W C M; Cheung, B M Y
2014-06-01
We assessed the effects of a bar-code assisted medication administration system used without the support of computerised prescribing (stand-alone BCMA), on the dispensing process and its users. The stand-alone BCMA system was implemented in one ward of a teaching hospital. The number of dispensing steps, dispensing time and potential dispensing errors (PDEs) were directly observed one month before and eight months after the intervention. Attitudes of pharmacy and nursing staff were assessed using a questionnaire (Likert scale) and interviews. Among 1291 and 471 drug items observed before and after the introduction of the technology respectively, the number of dispensing steps increased from five to eight and time (standard deviation) to dispense one drug item by one staff personnel increased from 0.8 (0.09) to 1.5 (0.12) min. Among 2828 and 471 drug items observed before and after the intervention respectively, the number of PDEs increased significantly (P<0.001). 'Procedural errors' and 'missing drug items' were the frequently observed PDEs in the after study. 'Perceived usefulness' and 'job relevance' of the technology decreased significantly (P=0.003 and P=0.004 respectively) among users who participated in the before (N=16) and after (N=16) questionnaires surveys. Among the interviewees, pharmacy staff felt that the system offered less benefit to the dispensing process (9/16). Nursing staff perceived the system as useful in improving the accuracy of drug administration (7/10). Implementing a stand-alone BCMA system may slow down and complicate the dispensing process. Nursing staff believe the stand-alone BCMA system could improve the drug administration process but pharmacy staff believes the technology would be more helpful if supported by computerised prescribing. However, periodical assessments are needed to identify weaknesses in the process after implementation, and all users should be educated on the benefits of using this technology. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Krzok, Franziska; Rieger, Verena; Niemann, Katharina; Nobis-Bosch, Ruth; Radermacher, Irmgard; Huber, Walter; Willmes, Klaus; Abel, Stefanie
2018-03-01
SAPS-'Sprachsystematisches Aphasiescreening'-is a novel language-systematic aphasia screening developed for the German language, which already had been positively evaluated. It offers a fast assessment of modality-specific psycholinguistic components at different levels of complexity and the derivation of impairment-based treatment foci from the individual performance profile. However, SAPS has not yet been evaluated in combination with the new SAPS-based treatment. To replicate the practicality of SAPS and to investigate the effectiveness of a SAPS-based face-to-face therapy combined with computerised home training in a feasibility study. To examine the soundness of the treatment design, to determine treatment-induced changes in patient performance as measured by SAPS, to assess parallel changes in communicative abilities, and to differentiate therapy effects achieved by face-to-face therapy versus add-on effects achieved by later home training. Sixteen participants with post-stroke aphasia (PWAs) were included into the study. They were administered the SAPS and communicative testing before and after the treatment regimen. Each PWA received one therapy session followed by home training per day, with the individual treatment foci being determined according to initial SAPS profile, and duration of treatment and possible change of focus dependent on performance assessed by continuous therapy monitoring. The combination of therapy and home training based on the SAPS was effective for all participants. We showed significant improvements for impairment-based SAPS performance and, with high inter-individual variability, in everyday communication. These two main targets of speech and language therapy were correlated and SAPS improvements after therapy were significantly higher than after home training. SAPS offers the assessment of an individual performance profile in order to derive sufficiently diversified, well-founded and specific treatment foci and to follow up changes in performance. The appending treatment regimen has shown to be effective for our participants. Thus, the study revealed feasibility of our approach. © 2017 Royal College of Speech and Language Therapists.
Miles, A; Chronakis, I; Fox, J; Mayer, A
2017-03-24
To develop a computerised decision aid (DA) to inform the decision process on adjuvant chemotherapy in patients with stage II colorectal cancer, and examine perceived usefulness, acceptability and areas for improvement of the DA. Mixed methods. Single outpatient oncology department in central London. Consecutive recruitment of 13 patients with stage II colorectal cancer, 12 of whom completed the study. Inclusion criteria were: age >18 years; complete resection for stage II adenocarcinoma of the colon or rectum; patients within 14-56 days after surgery; no contraindication to adjuvant chemotherapy; able to give written informed consent. Exclusion criterion: previous chemotherapy. Patient perceived usefulness (assessed by the PrepDM questionnaire) and acceptability of the DA. PrepDM scores, measuring the perceived usefulness of the DA in preparing the patient to communicate with their doctor and make a health decision, were above those reported in other patient groups. Patient acceptability scores were also high; however, interviews showed that there was evidence of a lack of understanding of key information among some patients, in particular their baseline risk of recurrence, the net benefit of combination chemotherapy and the rationale for having chemotherapy when cancer had apparently gone. Patients found the DA acceptable and useful in supporting their decision about whether or not to have adjuvant chemotherapy. Suggested improvements for the DA include: sequential presentation of treatment options (eg, no treatment vs 1 drug, 1 drug vs 2 drugs) to enhance patient understanding of the difference between combination and single therapy, diagrams to help patients understand the rationale for chemotherapy to prevent a recurrence and inbuilt checks on patient understanding of baseline risk of recurrence and net benefit of chemotherapy. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Vertebral body bone strength: the contribution of individual trabecular element morphology.
Parkinson, I H; Badiei, A; Stauber, M; Codrington, J; Müller, R; Fazzalari, N L
2012-07-01
Although the amount of bone explains the largest amount of variability in bone strength, there is still a significant proportion unaccounted for. The morphology of individual bone trabeculae explains a further proportion of the variability in bone strength and bone elements that contribute to bone strength depending on the direction of loading. Micro-CT imaging enables measurement of bone microarchitecture and subsequently mechanical strength of the same sample. It is possible using micro-CT data to perform morphometric analysis on individual rod and plate bone trabeculae using a volumetric spatial decomposition algorithm and hence determine their contribution to bone strength. Twelve pairs of vertebral bodies (T12/L1 or L4/L5) were harvested from human cadavers, and bone cubes (10 × 10 × 10 mm) were obtained. After micro-CT imaging, a volumetric spatial decomposition algorithm was applied, and measures of individual trabecular elements were obtained. Bone strength was measured in compression, where one bone specimen from each vertebral segment was tested supero-inferiorly (SI) and the paired specimen was tested antero-posteriorly (AP). Bone volume fraction was the strongest individual determinant of SI strength (r(2) = 0.77, p < 0.0001) and AP (r(2) = 0.54, p < 0.0001). The determination of SI strength was improved to r(2) = 0.87 with the addition of mean rod length and relative plate bone volume fraction. The determination of AP strength was improved to r(2) = 0.85 with the addition of mean rod volume and relative rod bone volume fraction. Microarchitectural measures of individual trabeculae that contribute to bone strength have been identified. In addition to the contribution of BV/TV, trabecular rod morphology increased the determination of AP strength by 57%, whereas measures of trabecular plate and rod morphology increased determination of SI strength by 13%. Decomposing vertebral body bone architecture into its constituent morphological elements shows that trabecular element morphology has specific functional roles to assist in maintaining skeletal integrity.
The Active Sites of a Rod-Shaped Hollandite DeNOx Catalyst.
Hu, Pingping; Schuster, Manfred Erwin; Huang, Zhiwei; Xu, Fei; Jin, Shifeng; Chen, Yaxin; Hua, Weiming; Su, Dang Sheng; Tang, Xingfu
2015-06-26
The identification of catalytically active sites (CASs) in heterogeneous catalysis is of vital importance to design and develop improved catalysts, but remains a great challenge. The CASs have been identified in the low-temperature selective catalytic reduction of nitrogen oxides by ammonia (SCR) over a hollandite manganese oxide (HMO) catalyst with a rod-shaped morphology and one-dimensional tunnels. Electron microscopy and synchrotron X-ray diffraction determine the surface and crystal structures of the one-dimensional HMO rods closed by {100} side facets and {001} top facets. A combination of X-ray absorption spectra, molecular probes with potassium and nitric oxide, and catalytic tests reveals that the CASs are located on the {100} side facets of the HMO rods rather than on the top facets or in the tunnels, and hence semi-tunnel structural motifs on the {100} facets are evidenced to be the CASs of the SCR reaction. This work paves the way to further investigate the intrinsic mechanisms of SCR reactions. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Bone response to a titanium aluminium nitride coating on metallic implants.
Freeman, C O; Brook, I M
2006-05-01
The design, surface characteristics and strength of metallic implants are dependant on their intended use and clinical application. Surface modifications of materials may enable reduction of the time taken for osseointegration and improve the biological response of bio-mechanically favourable metals and alloys. The influence of a titanium aluminium nitride (TAN) coating on the response of bone to commercially pure titanium and austenitic 18/8 stainless steel wire is reported. TAN coated and plain rods of stainless steel and commercially pure titanium were implanted into the mid-shaft of the femur of Wistar rats. The femurs were harvested at four weeks and processed for scanning electron and light microscopy. All implants exhibited a favourable response in bone with no evidence of fibrous encapsulation. There was no significant difference in the amount of new bone formed around the different rods (osseoconduction), however, there was a greater degree of shrinkage separation of bone from the coated rods than from the plain rods (p = 0.017 stainless steel and p = 0.0085 titanium). TAN coating may result in reduced osseointegration between bone and implant.
Hoffman, Kerry; Dempsey, Jennifer; Levett-Jones, Tracy; Noble, Danielle; Hickey, Noelene; Jeong, Sarah; Hunter, Sharyn; Norton, Carol
2011-08-01
This paper describes the conceptual design and testing of an Interactive Computerised Decision Support Framework (ICDSF) which was constructed to enable student nurses to "think like a nurse." The ICDSF was based on a model of clinical reasoning. Teaching student nurses to reason clinically is important as poor clinical reasoning skills can lead to "failure-to rescue" of deteriorating patients. The framework of the ICDSF was based on nursing concepts to encourage deep learning and transferability of knowledge. The principles of active student participation, situated cognition to solve problems, authenticity, and cognitive rehearsal were used to develop the ICDSF. The ICDSF was designed in such a way that students moved through it in a step-wise fashion and were required to achieve competency at each step before proceeding to the next. The quality of the ICDSF was evaluated using a questionairre survey, students' written comments and student assessment measures on a pilot and the ICDSF. Overall students were highly satisfied with the clinical scenarios of the ICDSF and believed they were an interesting and useful way to engage in authentic clinical learning. They also believed the ICDSF was useful in developing cognitive skills such as clinical reasoning, problem-solving and decision-making. Some reported issues were the need for good technical support and the lack of face to face contact when using e-learning. Some students also believed the ICDSF was less useful than actual clinical placements. Copyright © 2010 Elsevier Ltd. All rights reserved.
Computerised Order Entry Systems and Pathology Services - A Synthesis of the Evidence
Georgiou, Andrew; Westbrook, Johanna I
2006-01-01
Computerised Physician Order Entry (CPOE) systems have been promoted in Australia and internationally for their potential to improve the quality of care. The existing research of the effect of CPOE on pathology laboratories has been variable, pointing to the potential to increase efficiency and effectiveness and contribute to enhancing the quality of patient care on the one hand, while leading to significant disruptions in work organisation with a negative impact on departmental relations on the other hand. In this paper we provide an overview of the research evidence about the impact of CPOE on four areas associated with pathology services; a) efficiency of the ordering process, e.g. test turnaround times, b) effectiveness as measured by test ordering volumes and test order appropriateness, c) quality of care, particularly its effects on patient care and d) work organisation patterns, which can be severely disrupted by CPOE. We discuss the possible ramifications of CPOE and offer three broad, but important recommendations for pathology laboratories, based on our own research experience investigating CPOE implementations over three years. Firstly, pathology laboratories need to be active participants in planning the implementation of CPOE. Secondly, the importance of building a firm organisational foundation for the introduction of the new system that includes openness and responsiveness to feedback. And thirdly, the implementation process needs to be underpinned by a strong commitment to a multi-method evaluation at every stage of the process to be able to measure the impact of the system on work practices and outcomes. PMID:17077878
Validity and reliability of acoustic analysis of respiratory sounds in infants
Elphick, H; Lancaster, G; Solis, A; Majumdar, A; Gupta, R; Smyth, R
2004-01-01
Objective: To investigate the validity and reliability of computerised acoustic analysis in the detection of abnormal respiratory noises in infants. Methods: Blinded, prospective comparison of acoustic analysis with stethoscope examination. Validity and reliability of acoustic analysis were assessed by calculating the degree of observer agreement using the κ statistic with 95% confidence intervals (CI). Results: 102 infants under 18 months were recruited. Convergent validity for agreement between stethoscope examination and acoustic analysis was poor for wheeze (κ = 0.07 (95% CI, –0.13 to 0.26)) and rattles (κ = 0.11 (–0.05 to 0.27)) and fair for crackles (κ = 0.36 (0.18 to 0.54)). Both the stethoscope and acoustic analysis distinguished well between sounds (discriminant validity). Agreement between observers for the presence of wheeze was poor for both stethoscope examination and acoustic analysis. Agreement for rattles was moderate for the stethoscope but poor for acoustic analysis. Agreement for crackles was moderate using both techniques. Within-observer reliability for all sounds using acoustic analysis was moderate to good. Conclusions: The stethoscope is unreliable for assessing respiratory sounds in infants. This has important implications for its use as a diagnostic tool for lung disorders in infants, and confirms that it cannot be used as a gold standard. Because of the unreliability of the stethoscope, the validity of acoustic analysis could not be demonstrated, although it could discriminate between sounds well and showed good within-observer reliability. For acoustic analysis, targeted training and the development of computerised pattern recognition systems may improve reliability so that it can be used in clinical practice. PMID:15499065
High-strength tungsten alloy with improved ductility
NASA Technical Reports Server (NTRS)
Klopp, W. D.; Raffo, P. L.; Rubenstein, L. S.; Witzke, W. R.
1967-01-01
Alloy combines superior strength at elevated temperatures with improved ductility at lower temperatures relative to unalloyed tungsten. Composed of tungsten, rhenium, hafnium, and carbon, the alloy is prepared by consumable electrode vacuum arc-melting and can be fabricated into rod, plate, and sheet.
Long-term effects of retinopathy of prematurity (ROP) on rod and rod-driven function.
Harris, Maureen E; Moskowitz, Anne; Fulton, Anne B; Hansen, Ronald M
2011-02-01
The purpose of this study was to determine whether recovery of scotopic sensitivity occurs in human ROP, as it does in the rat models of ROP. Following a cross-sectional design, scotopic electroretinographic (ERG) responses to full-field stimuli were recorded from 85 subjects with a history of preterm birth. In 39 of these subjects, dark adapted visual threshold was also measured. Subjects were tested post-term as infants (median age 2.5 months) or at older ages (median age 10.5 years) and stratified by severity of ROP: severe, mild, or none. Rod photoreceptor sensitivity, S (ROD), was derived from the a-wave, and post-receptor sensitivity, log σ, was calculated from the b-wave stimulus-response function. Dark adapted visual threshold was measured using a forced-choice preferential procedure. For S (ROD), the deficit from normal for age varied significantly with ROP severity but not with age group. For log σ, in mild ROP, the deficit was smaller in older subjects than in infants, while in severe ROP, the deficit was quite large in both age groups. In subjects who never had ROP, S (ROD) and log σ in both age groups were similar to those in term born controls. Deficits in dark adapted threshold and log σ were correlated in mild but not in severe ROP. The data are evidence that sensitivity of the post-receptor retina improves in those with a history of mild ROP. We speculate that beneficial reorganization of the post-receptor neural circuitry occurs in mild but not in severe ROP.
BISON Fuel Performance Analysis of IFA-796 Rod 3 & 4 and Investigation of the Impact of Fuel Creep
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wirth, Brian; Terrani, Kurt A.; Sweet, Ryan T.
In order to improve the accident tolerance of light water reactor (LWR) fuel, alternative cladding materials have been proposed to replace the currently used zirconium (Zr)-based alloys. Of these materials, there is a particular focus on iron-chromiumaluminum (FeCrAl) alloys because they exhibit slower oxidation kinetics in high-temperature steam than Zr-alloys. This should decrease the energy release due to oxidation and slow cladding consumption in the presence of high temperature steam. These alloys should also exhibit increased “coping time” in the event of an accident scenario by improving the mechanical performance at high temperatures, allowing greater flexibility to achieve core cooling.more » As a continuation of the development of these alloys, in-reactor irradiation testing of FeCrAl cladded fuel rods has started. In order to provide insight on the possible behavior of these fuel rods as they undergo irradiation in the Halden Boiling Water Reactor, engineering analysis has been performed using FeCrAl material models implemented into the BISON fuel performance code. This milestone report provides an update on the ongoing development of modeling capability to predict FeCrAl cladding fuel performance and to provide an early look at the possible behavior of planned in-reactor FeCrAl cladding experiments. In particular, this report consists of two separate analyses. The first analysis consists of fuel performance simulations of IFA-796 rod 4 and two segments of rod 3. These simulations utilize previously implemented material models for the C35M FeCrAl alloy and UO2 to provide a bounding behavior analysis corresponding to variation of the initial fuel cladding gap thickness within the fuel rod. The second analysis is an assessment of the fuel and cladding stress states after modification of the fuel creep model that is currently implemented in the BISON fuel performance code. Effects from modifying the fuel creep model were identified for the BISON simulations of the IFA-796 rod 4 experiment, but show that varying the creep model (within the range investigated here) only provide a minimal increase in the fuel radius and maximum cladding hoop stress. Continued investigation of fuel behavioral models will include benchmarking the modified fuel creep model against available experimental data, as well as an investigation of the role that fuel cracking will play in the compliance of the fuel. Correctly calculating stress evolution in the fuel is key to assessing fuel behavior up to gap closure and the subsequent deformation of the cladding due to PCMI. The inclusion of frictional contact should also be investigated to determine the axial elongation of the fuel rods for comparison with data from this experiment.« less
Improved method of preparing composite superconducting wire
Verhoeven, J.D.; Gibson, E.D.; Finnemore, D.K.; Ostenson, J.E.; Schmidt, F.A.; Owen, C.V.
1979-10-17
An improved method of preparing composite multifilament superconducting wire of Nb/sub 3/Sn in a copper matrix eliminates the necessity of coating the drawn wire with tin. A generalized cylindrical billet of an alloy of copper containing at least 15 weight percent niobium, present in the copper as discrete, randomly distributed and oriented dendritic-shaped particles, is provided with at least one longitudinal opening which is filled with tin to form a composite drawing rod. The drawing rod is then drawn to form a ductile composite multifilament wire containing a filament of tin. The ductile wire containing the tin can then be wound into magnet coils or other devices before heating to diffuse the tin through the wire to react with the niobium forming Nb/sub 3/Sn. Also described is an improved method for making large billets of the copper-niobium alloy by consumable-arc casting.
Total hip arthroplasty in dwarfism. A case report.
De Fine, Marcello; Traina, Francesco; Palmonari, Massimo; Tassinari, Enrico; Toni, Aldo
2008-05-01
In dwarfism hip arthritis, usually secondary to hip dysplasia, is a common finding at an early age. In these patients a joint replacement is a demanding procedure due to the peculiar joint deformity and the small size of the bones. We present a case of a bilateral hip replacement in a dwarf patient. In order to reduce intraoperative complications and improve the joint kinematics a thorough preoperative planning was performed by a CT based computerised system. On the basis of the planning we chose a conical shaped stem that enable as to restore limb length and offset with a low risk of femoral fracture. In conclusion, we consider total hip replacement in dwarfism a safe and effective procedure if an accurate preoperative planning is performed.
Toit, Nicole du; Burden, Faith A; Kempson, Sue A; Dixon, Padraic M
2008-12-01
Post-mortem examination of 16 donkey cheek teeth (CT) with caries (both peripheral and infundibular) and pulpar exposure were performed using computerised axial tomography (CAT), histology and scanning electron microscopy. CAT imaging was found to be useful to assess the presence and extent of caries and pulp exposure in individual donkey CT. Histology identified the loss of occlusal secondary dentine, and showed pulp necrosis in teeth with pulpar exposure. Viable pulp was present more apically in one exposed pulp horn, with its occlusal aspect sealed off from the exposed aspect of the pulp horn by a false pulp stone. Scanning electron microscopy showed the amelo-cemental junction to be a possible route of bacterial infection in infundibular cemental caries. The basic pathogenesis of dental caries in donkeys appears very similar to its description in other species.
D'Orso, M I; Centemeri, R; Latocca, R; Riva, M; Cesana, G
2012-01-01
Occupational Health Doctors active in building sector firms frequently have to evaluate residual workers' osteomuscular function in patients coming back to work after an accident happened during work time or free time. Definition of their specific individual work suitability is usually carried out utilizing semeiotic tests in which subjective evaluation of every single Medical Doctor is real important in definition of final results and this fact can cause legal controversies. In our research we describe the application of computerised movement analysis on 10 workers of building sector. In every patient examined this technical method has been able to study objectively the tridimensional ranges of motion of most important osteomuscular districts. The possibility to have an objective evaluation of residual osteomuscular function has a relevant importance both in definition of workers' work suitability at the moment in which they start again their activities and in possible future legal conflicts.
Geospatial Data for Computerisation of Public Administration in the Czech Republic
NASA Astrophysics Data System (ADS)
Cada, V.; Mildorf, T.
2011-08-01
The main aim of the eGovernment programme in the Czech Republic is to enhance the efficiency of public administration. The Digital Map of Public Administration (DMVS) should be composed of digital orthophotographs of the Czech Republic, digital and digitised cadastral maps, digital purpose cadastral map (ÚKM) and a technical map of municipality, if available. The DMVS project is a part of computerisation of public administration in the Czech Republic. The project enhances the productivity of government administration and also simplifies the processes between citizens and public administration. The DMVS project, that should be compliant with the INSPIRE (Infrastructure for Spatial Information in the European Community) initiative, generates definite demand for geodata on the level of detail of land data model. The user needs that are clearly specified and required are not met due to inconsistencies in terminology, data management and level of detail.
[Computerised monitoring of integrated cervical screening. Indicators of diagnostic performance].
Bucchi, L; Pierri, C; Amadori, A; Folicaldi, S; Ghidoni, D; Nannini, R; Bondi, A
2003-12-01
In a previous issue of this journal, we presented the background, rationale, general methods, and indicators of participation of a computerised system for the monitoring of integrated cervical screening, i.e. the integration of spontaneous Pap smear practice into organised screening. We also reported the results of the application of those indicators in the general database of the Pathology Department of Imola Health District in northern Italy. In the current paper, we present the rationale and definitions of indicators of diagnostic performance (total Pap smears and rate of unsatisfactory Pap smears, distribution by cytology class reported, rate of patients without timely follow-up, detection rate, positive predictive value, distribution of cytology classes reported by histology diagnosis, and distribution of cases of CIN and carcinoma registered by detection modality) as well as the results of their application in the same database as above.
Computer-assisted image processing to detect spores from the fungus Pandora neoaphidis.
Korsnes, Reinert; Westrum, Karin; Fløistad, Erling; Klingen, Ingeborg
2016-01-01
This contribution demonstrates an example of experimental automatic image analysis to detect spores prepared on microscope slides derived from trapping. The application is to monitor aerial spore counts of the entomopathogenic fungus Pandora neoaphidis which may serve as a biological control agent for aphids. Automatic detection of such spores can therefore play a role in plant protection. The present approach for such detection is a modification of traditional manual microscopy of prepared slides, where autonomous image recording precedes computerised image analysis. The purpose of the present image analysis is to support human visual inspection of imagery data - not to replace it. The workflow has three components:•Preparation of slides for microscopy.•Image recording.•Computerised image processing where the initial part is, as usual, segmentation depending on the actual data product. Then comes identification of blobs, calculation of principal axes of blobs, symmetry operations and projection on a three parameter egg shape space.
Carnie, J; Boden, J; Gao Smith, F
2002-07-01
In this single group observational study on 29 patients, we describe a technique that predicts the depth of the epidural space, calculated from the routine pre-operative chest computerised tomography (CT) scan using Pythagorean triangle trigonometry. We also compared the CT-derived depth of the epidural space with the actual depth of needle insertion. The CT-derived and the actual depths of the epidural space were highly correlated (r = 0.88, R2 = 0.78, p < 0.0001). The mean (95% CI) difference between CT-derived and actual depths was 0.26 (0.03-0.49) cm. Thus, the CT-derived depth tends to be greater than the actual depth by between 0.03 and 0.49 cm. There were no associations between either the CT-derived or the actual depth of the epidural space and age, weight, height or body mass index.
Reprogramming metabolism by targeting sirtuin 6 attenuates retinal degeneration
Zhang, Lijuan; Du, Jianhai; Justus, Sally; Hsu, Chun-Wei; Bonet-Ponce, Luis; Wu, Wen-Hsuan; Tsai, Yi-Ting; Wu, Wei-Pu; Jia, Yading; Duong, Jimmy K.; Mahajan, Vinit B.; Lin, Chyuan-Sheng; Wang, Shuang; Hurley, James B.
2016-01-01
Retinitis pigmentosa (RP) encompasses a diverse group of Mendelian disorders leading to progressive degeneration of rods and then cones. For reasons that remain unclear, diseased RP photoreceptors begin to deteriorate, eventually leading to cell death and, consequently, loss of vision. Here, we have hypothesized that RP associated with mutations in phosphodiesterase-6 (PDE6) provokes a metabolic aberration in rod cells that promotes the pathological consequences of elevated cGMP and Ca2+, which are induced by the Pde6 mutation. Inhibition of sirtuin 6 (SIRT6), a histone deacetylase repressor of glycolytic flux, reprogrammed rods into perpetual glycolysis, thereby driving the accumulation of biosynthetic intermediates, improving outer segment (OS) length, enhancing photoreceptor survival, and preserving vision. In mouse retinae lacking Sirt6, effectors of glycolytic flux were dramatically increased, leading to upregulation of key intermediates in glycolysis, TCA cycle, and glutaminolysis. Both transgenic and AAV2/8 gene therapy–mediated ablation of Sirt6 in rods provided electrophysiological and anatomic rescue of both rod and cone photoreceptors in a preclinical model of RP. Due to the extensive network of downstream effectors of Sirt6, this study motivates further research into the role that these pathways play in retinal degeneration. Because reprogramming metabolism by enhancing glycolysis is not gene specific, this strategy may be applicable to a wide range of neurodegenerative disorders. PMID:27841758
Kim, Kyeong Heon; Lee, Tae Ho; Kim, Tae Geun
2017-07-19
A hybrid-type transparent conductive electrode (H-TCE) structure comprising an AlN rod array with conducting filaments (CFs) and indium tin oxide (ITO) films is proposed to improve both current injection and distribution as well as optical transmittance in the UV region. These CFs, generated in UV-transparent AlN rod areas using an electric field, can be used as conducting paths for carrier injection from a metal to a semiconductor such as p-(Al)GaN, which allows perfect Ohmic behavior with high transmittance (>95% at 365 nm) to be obtained. In addition, conduction across AlN rods and Ohmic conduction mechanisms are investigated by analyzing AlN rods and AlN rod/p-AlGaN film interfaces. We apply these H-TCEs to three near-UV light-emitting diodes (LEDs) (385 nm LEDs with p-GaN and p-AlGaN terminated surfaces and 365 nm LED with p-AlGaN terminated surface). We confirm that the light power outputs increase by 66%, 79%, and 103%, whereas the forward voltages reduce by 5.6%, 10.2%, and 8.6% for 385 nm p-GaN terminated, 385 nm p-AlGaN terminated, and 365 nm p-AlGaN terminated LEDs with H-TCEs, respectively, compared to LEDs with reference ITOs.
NASA Technical Reports Server (NTRS)
Marcum, Jeremy W.; Olson, Sandra L.; Ferkul, Paul V.
2016-01-01
The axisymmetric rod geometry in upward axial stagnation flow provides a simple way to measure normal gravity blowoff limits to compare with microgravity Burning and Suppression of Solids - II (BASS-II) results recently obtained aboard the International Space Station. This testing utilized the same BASS-II concurrent rod geometry, but with the addition of normal gravity buoyant flow. Cast polymethylmethacrylate (PMMA) rods of diameters ranging from 0.635 cm to 3.81 cm were burned at oxygen concentrations ranging from 14 to 18% by volume. The forced flow velocity where blowoff occurred was determined for each rod size and oxygen concentration. These blowoff limits compare favorably with the BASS-II results when the buoyant stretch is included and the flow is corrected by considering the blockage factor of the fuel. From these results, the normal gravity blowoff boundary for this axisymmetric rod geometry is determined to be linear, with oxygen concentration directly proportional to flow speed. We describe a new normal gravity 'upward flame spread test' method which extrapolates the linear blowoff boundary to the zero stretch limit in order to resolve microgravity flammability limits-something current methods cannot do. This new test method can improve spacecraft fire safety for future exploration missions by providing a tractable way to obtain good estimates of material flammability in low gravity.
Development of a new bench for puncturing of irradiated fuel rods in STAR hot laboratory
NASA Astrophysics Data System (ADS)
Petitprez, B.; Silvestre, P.; Valenza, P.; Boulore, A.; David, T.
2018-01-01
A new device for puncturing of irradiated fuel rods in commercial power plants has been designed by Fuel Research Department of CEA Cadarache in order to provide experimental data of high precision on fuel pins with various designs. It will replace the current set-up that has been used since 1998 in hot cell 2 of STAR facility with more than 200 rod puncturing experiments. Based on this consistent experimental feedback, the heavy-duty technique of rod perforation by clad punching has been preserved for the new bench. The method of double expansion of rod gases is also retained since it allows upgrading the confidence interval of volumetric results obtained from rod puncturing. Furthermore, many evolutions have been introduced in the new design in order to improve its reliability, to make the maintenance easier by remote handling and to reduce experimental uncertainties. Tightness components have been studied with Sealing Laboratory Maestral at Pierrelatte so as to make them able to work under mixed pressure conditions (from vacuum at 10-5 mbar up to pressure at 50 bars) and to lengthen their lifetime under permanent gamma irradiation in hot cell. Bench ergonomics has been optimized to make its operating by remote handling easier and to secure the critical phases of a puncturing experiment. A high pressure gas line equipped with high precision pressure sensors out of cell can be connected to the bench in cell for calibration purposes. Uncertainty analyses using Monte Carlo calculations have been performed in order to optimize capacity of the different volumes of the apparatus according to volumetric characteristics of the rod to be punctured. At last this device is composed of independent modules which allow puncturing fuel pins out of different geometries (PWR, BWR, VVER). After leak tests of the device and remote handling simulation in a mock-up cell, several punctures of calibrated specimens have been performed in 2016. The bench will be implemented soon in hot cell 2 of STAR facility for final qualification tests. PWR rod punctures are already planned for 2018.
Ntoumenopoulos, G; Glickman, Y
2012-09-01
To explore the feasibility of computerised lung sound monitoring to evaluate secretion removal in intubated and mechanically ventilated adult patients. Before and after observational investigation. Intensive care unit. Fifteen intubated and mechanically ventilated adult patients receiving chest physiotherapy. Chest physiotherapy included combinations of standard closed airway suctioning, saline lavage, postural drainage, chest wall vibrations, manual-assisted cough and/or lung hyperinflation, dependent upon clinical indications. Lung sound amplitude at peak inspiration was assessed using computerised lung sound monitoring. Measurements were performed immediately before and after chest physiotherapy. Data are reported as mean [standard deviation (SD)], mean difference and 95% confidence intervals (CI). Significance testing was not performed due to the small sample size and the exploratory nature of the study. Fifteen patients were included in the study [11 males, four females, mean age 65 (SD 14) years]. The mean total lung sound amplitude at peak inspiration decreased two-fold from 38 (SD 59) units before treatment to 17 (SD 19) units after treatment (mean difference 22, 95% CI of difference -3 to 46). The mean total lung sound amplitude from the lungs of patients with a large amount of secretions (n=9) was over four times 'louder' than the lungs of patients with a moderate or small amount of secretions (n=6) [56 (SD 72) units vs 12 (13) units, respectively; mean difference -44, 95% CI of difference -100 to 11]. The mean total lung sound amplitude decreased in the group of 'loud' right and left lungs (n=15) from 37 (SD 36) units before treatment to 15 (SD 13) units after treatment (mean difference 22, 95% CI of difference 6 to 38). Computerised lung sound monitoring in this small group of patients demonstrated a two-fold decrease in lung sound amplitude following chest physiotherapy. Subgroup analysis also demonstrated decreasing trends in lung sound amplitude in the group of 'loud' lungs following chest physiotherapy. Due to the small sample size and large SDs with high variability in the lung sound amplitude measurements, significance testing was not reported. Further investigation is needed in a larger sample of patients with more accurate measurement of sputum wet weight in order to distinguish between secretion-related effects and changes due to other factors such as airflow rate and pattern. Copyright © 2012 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Zhang, Yushu; Zhang, Chuanlian; Liu, Kemiao; Zhu, Xia; Liu, Fang; Ge, Xiaofen
2018-05-01
The aim of the present study is to develop novel approach for the green synthesis of titanium oxide nanoparticles (TiO 2 NPs) using Eichhornia crassipes extract and calcined at different temperatures for evaluate the wound healing activity in the femoral fracture. The synthesized TiO 2 are formed different (plate and rod-like) nanostructures at various calcination temperatures. These samples were characterized by X-ray diffraction (XRD), Fourier transform-infrared spectroscopy (FTIR), Field emission scanning electron microscope (FE-SEM) and transmission electron microscope (TEM). Microscopic studies of TiO 2 NPs revealed that the synthesized TiO 2 NPs are formed well-defined rod-like structures at 400 °C with size ranged from 200 nm to 500 nm. The characterized plate and rod-like TiO 2 NPs are combined with human morphogenetic protein (HbMP) to improving its wound healing activity and osteoblast properties on femoral fractures. The biocompatibility was tested by using human bone marrow mesenchymal stem cells (BMSC) cells and antibacterial efficacy analyzed using human pathogenica bacteria Staphylococcus aureus and Escherichia coli through agar well diffusion assay. The green synthesized rod-like TiO 2 NPs combined with HbMP has been exhibited effective bone fusion behaviors with biomechanical properties and also improved antibacterial activity against pathogenic bacteria. From this study results, it is suggested that green synthesized TiO 2 NPs could be used effectively in biomedical application. Copyright © 2018. Published by Elsevier B.V.
An Avoidance Model for Short-Range Order Induced by Soft Repulsions in Systems of Rigid Rods
NASA Astrophysics Data System (ADS)
Han, Jining; Herzfeld, Judith
1996-03-01
The effects of soft repulsions on hard particle systems are calculated using an avoidance model which improves upon the simple mean field approximation. Avoidance reduces, but does not eliminate, the energy due to soft repulsions. On the other hand, it also reduces the configurational entropy. Under suitable conditions, this simple trade-off yields a free energy that is lower than the mean field value. In these cases, the variationally determined avoidance gives an estimate for the short-range positional order induced by soft repulsions. The results indicate little short-range order for isotropically oriented rods. However, for parallel rods, short-range order increases to significant levels as the particle axial ratio increases. The implications for long- range positional ordering are also discussed. In particular, avoidance may explain the smectic ordering of tobacco mosaic virus at volume fractions lower than those necessary for smectic ordering of hard particles.
Enhanced Phosphorylation-Independent Arrestins and Gene Therapy
Gurevich, Vsevolod V.; Song, Xiufeng; Vishnivetskiy, Sergey A.; Gurevich, Eugenia V.
2015-01-01
A variety of heritable and acquired disorders is associated with excessive signaling by mutant or overstimulated GPCRs. Since any conceivable treatment of diseases caused by gain-of-function mutations requires gene transfer, one possible approach is functional compensation. Several structurally distinct forms of enhanced arrestins that bind phosphorylated and even non-phosphorylated active GPCRs with much higher affinity than parental wild-type proteins have the ability to dampen the signaling by hyperactive GPCR, pushing the balance closer to normal. In vivo this approach was so far tested only in rod photoreceptors deficient in rhodopsin phosphorylation, where enhanced arrestin improved the morphology and light sensitivity of rods, prolonged their survival, and accelerated photoresponse recovery. Considering that rods harbor the fastest, as well as the most demanding and sensitive GPCR-driven signaling cascade, even partial success of functional compensation of defect in rhodopsin phosphorylation by enhanced arrestin demonstrates the feasibility of this strategy and its therapeutic potential. PMID:24292828
Xu, Yi-Ting; Xu, Jia-Lin; Guo, Ya-Ding; Yang, Feng-Tu; Chen, Yan-Zhong; Xu, Jian; Xie, Shi-Yong; Bo, Yong; Peng, Qin-Jun; Cui, Dafu; Xu, Zu-Yan
2010-08-20
We present a compact high-efficiency and high-average-power diode-side-pumped Nd:YAG rod laser oscillator operated with a linearly polarized fundamental mode. The oscillator resonator is based on an L-shaped convex-convex cavity with an improved module and a dual-rod configuration for birefringence compensation. Under a pump power of 344 W, a linearly polarized average output power of 101.4 W at 1064 nm is obtained, which corresponds to an optical-to-optical conversion efficiency of 29.4%. The laser is operated at a repetition rate of 400 Hz with a beam quality factor of M(2)=1.14. To the best of our knowledge, this is the highest optical-to-optical efficiency for a side-pumped TEM(00) Nd:YAG rod laser oscillator with a 100-W-level output ever reported.
Isaacson, M D; Srinivasan, S; Lloyd, L L
2010-01-01
MathSpeak is a set of rules for non speaking of mathematical expressions. These rules have been incorporated into a computerised module that translates printed mathematics into the non-ambiguous MathSpeak form for synthetic speech rendering. Differences between individual utterances produced with the translator module are difficult to discern because of insufficient pausing between utterances; hence, the purpose of this study was to develop an algorithm for improving the synthetic speech rendering of MathSpeak. To improve synthetic speech renderings, an algorithm for inserting pauses was developed based upon recordings of middle and high school math teachers speaking mathematic expressions. Efficacy testing of this algorithm was conducted with college students without disabilities and high school/college students with visual impairments. Parameters measured included reception accuracy, short-term memory retention, MathSpeak processing capacity and various rankings concerning the quality of synthetic speech renderings. All parameters measured showed statistically significant improvements when the algorithm was used. The algorithm improves the quality and information processing capacity of synthetic speech renderings of MathSpeak. This increases the capacity of individuals with print disabilities to perform mathematical activities and to successfully fulfill science, technology, engineering and mathematics academic and career objectives.
A key role for cyclic nucleotide gated (CNG) channels in cGMP-related retinitis pigmentosa.
Paquet-Durand, François; Beck, Susanne; Michalakis, Stylianos; Goldmann, Tobias; Huber, Gesine; Mühlfriedel, Regine; Trifunović, Dragana; Fischer, M Dominik; Fahl, Edda; Duetsch, Gabriele; Becirovic, Elvir; Wolfrum, Uwe; van Veen, Theo; Biel, Martin; Tanimoto, Naoyuki; Seeliger, Mathias W
2011-03-01
The rd1 natural mutant is one of the first and probably the most commonly studied mouse model for retinitis pigmentosa (RP), a severe and frequently blinding human retinal degeneration. In several decades of research, the link between the increase in photoreceptor cGMP levels and the extremely rapid cell death gave rise to a number of hypotheses. Here, we provide clear evidence that the presence of cyclic nucleotide gated (CNG) channels in the outer segment membrane is the key to rod photoreceptor loss. In Cngb1(-/-) × rd1 double mutants devoid of regular CNG channels, cGMP levels are still pathologically high, but rod photoreceptor viability and outer segment morphology are greatly improved. Importantly, cone photoreceptors, the basis for high-resolution daylight and colour vision, survived and remained functional for extended periods of time. These findings strongly support the hypothesis of deleterious calcium (Ca(2+))-influx as the cause of rapid rod cell death and highlight the importance of CNG channels in this process. Furthermore, our findings suggest that targeting rod CNG channels, rather than general Ca(2+)-channel blockade, is a most promising symptomatic approach to treat otherwise incurable forms of cGMP-related RP.
Sudo, Hideki; Ito, Manabu; Abe, Yuichiro; Abumi, Kuniyoshi; Takahata, Masahiko; Nagahama, Ken; Hiratsuka, Shigeto; Kuroki, Kei; Iwasaki, Norimasa
2014-06-15
Retrospective analysis of a prospectively collected, consecutive, nonrandomized series of patients. To assess the surgical outcomes of the simultaneous double-rod rotation technique for treating Lenke 1 thoracic adolescent idiopathic scoliosis (AIS). With the increasing popularity of segmental pedicle screw spinal reconstruction for treating AIS, concerns regarding the limited ability to correct hypokyphosis have also increased. A consecutive series of 32 patients with Lenke 1 main thoracic AIS treated with the simultaneous double-rod rotation technique at our institution was included. Outcome measures included patient demographics, radiographical measurements, and Scoliosis Research Society questionnaire scores. All 32 patients were followed up for a minimum of 2 years (average, 3.6 yr). The average main thoracic Cobb angle correction rate and the correction loss at the final follow-up were 67.8% and 3.3°, respectively. The average preoperative thoracic kyphosis (T5-T12) was 11.9°, which improved significantly to 20.5° (P < 0.0001) at the final follow-up. An increase in thoracic kyphosis was significantly correlated with an increase in lumbar lordosis at the final follow-up (r = 0.42). The average preoperative vertebral rotation angle was 19.7°, which improved significantly after surgery to 14.9° (P = 0.0001). There was no correlation between change in thoracic kyphosis and change in apical vertebral rotation (r =-0.123). The average preoperative total Scoliosis Research Society questionnaire score was 3.0, which significantly improved to 4.4 (P < 0.0001) at the final follow-up. Throughout surgery and even after, there were no instrumentation failures, pseudarthrosis, infection of the surgical site, or clinically relevant neurovascular complications. The simultaneous double-rod rotation technique for treating Lenke 1 AIS provides significant sagittal correction of the main thoracic curve while maintaining sagittal profiles and correcting coronal and axial deformities. 4.
Occasional Papers in Open and Distance Learning, Number 14.
ERIC Educational Resources Information Center
Donnan, Peter, Ed.
Five papers focussing on educational technology are presented in this issue. "Computerised Instructional Technologies: Considerations for Lectures and Instructional Designers" (Helen Geissinger) and "The Higher Education Distance Learner and Technology" (Terry Geddes) locates the new technologies within a solidly grounded…
Active Interfacial Shear Microrheology of Aging Protein Films
Dhar, Prajnaparamita; Cao, Yanyan; Fischer, Thomas M.; Zasadzinski, J. A.
2012-01-01
The magnetically driven rotation of 300 nm diameter rods shows the surface viscosity of albumin at an air-water interface increases from 10−9 to 10−5 Ns/m over two hours while the surface pressure saturates in minutes. The increase in surface viscosity is not accompanied by a corresponding increase in elasticity, suggesting that the protein film anneals with time, resulting in a more densely packed film leading to increased resistance to shear. The nanometer dimensions of the rods provide the same sensitivity as passive microrheology with an improved ability to measure more viscous films. PMID:20366371
Epitaxial growth of quantum rods with high aspect ratio and compositional contrast
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, L. H.; Patriarche, G.; Fiore, A.
2008-12-01
The epitaxial growth of quantum rods (QRs) on GaAs was investigated. It was found that GaAs thickness in the GaAs/InAs superlattice used for QR formation plays a key role in improving the QR structural properties. Increasing the GaAs thickness results in both an increased In compositional contrast between the QRs and surrounding layer, and an increased QR length. QRs with an aspect ratio of up to 10 were obtained, representing quasiquantum wires in a GaAs matrix. Due to modified confinement and strain potential, such nanostructure is promising for controlling gain polarization.
Bourdeaux, Christopher P; Davies, Keith J; Thomas, Matthew J C; Bewley, Jeremy S; Gould, Timothy H
2014-05-01
Computerised order sets have the potential to reduce clinical variation and improve patient safety but the effect is variable. We sought to evaluate the impact of changes to the design of an order set on the delivery of chlorhexidine mouthwash and hydroxyethyl starch (HES) to patients in the intensive care unit. The study was conducted at University Hospitals Bristol NHS Foundation Trust, UK. Our intensive care unit uses a clinical information system (CIS). All drugs and fluids are prescribed with the CIS and drug and fluid charts are stored within a database. Chlorhexidine mouthwash was added as a default prescription to the prescribing template in January 2010. HES was removed from the prescribing template in April 2009. Both interventions were available to prescribe manually throughout the study period. We conducted a database review of all patients eligible for each intervention before and after changes to the configuration of choices within the prescribing system. 2231 ventilated patients were identified as appropriate for treatment with chlorhexidine, 591 before the intervention and 1640 after. 55.3% were prescribed chlorhexidine before the change and 90.4% after (p<0.001). 6199 patients were considered in the HES intervention, 2177 before the intervention and 4022 after. The mean volume of HES infused per patient fell from 630 mL to 20 mL after the change (p<0.001) and the percentage of patients receiving HES fell from 54.1% to 3.1% (p<0.001). These results were well sustained with time. The presentation of choices within an electronic prescribing system influenced the delivery of evidence-based interventions in a predictable way and the effect was well sustained. This approach has the potential to enhance the effectiveness of computerised order sets.
Shulman, Rob; Singer, Mervyn; Goldstone, John; Bellingan, Geoff
2005-10-05
The study aimed to compare the impact of computerised physician order entry (CPOE) without decision support with hand-written prescribing (HWP) on the frequency, type and outcome of medication errors (MEs) in the intensive care unit. Details of MEs were collected before, and at several time points after, the change from HWP to CPOE. The study was conducted in a London teaching hospital's 22-bedded general ICU. The sampling periods were 28 weeks before and 2, 10, 25 and 37 weeks after introduction of CPOE. The unit pharmacist prospectively recorded details of MEs and the total number of drugs prescribed daily during the data collection periods, during the course of his normal chart review. The total proportion of MEs was significantly lower with CPOE (117 errors from 2429 prescriptions, 4.8%) than with HWP (69 errors from 1036 prescriptions, 6.7%) (p < 0.04). The proportion of errors reduced with time following the introduction of CPOE (p < 0.001). Two errors with CPOE led to patient harm requiring an increase in length of stay and, if administered, three prescriptions with CPOE could potentially have led to permanent harm or death. Differences in the types of error between systems were noted. There was a reduction in major/moderate patient outcomes with CPOE when non-intercepted and intercepted errors were combined (p = 0.01). The mean baseline APACHE II score did not differ significantly between the HWP and the CPOE periods (19.4 versus 20.0, respectively, p = 0.71). Introduction of CPOE was associated with a reduction in the proportion of MEs and an improvement in the overall patient outcome score (if intercepted errors were included). Moderate and major errors, however, remain a significant concern with CPOE.
Chow, A L; Ang, A; Chow, C Z; Ng, T M; Teng, C; Ling, L M; Ang, B S; Lye, D C
2016-02-01
Antimicrobial stewardship is used to combat antimicrobial resistance. In Singapore, a tertiary hospital has integrated a computerised decision support system, called Antibiotic Resistance Utilisation and Surveillance-Control (ARUSC), into the electronic inpatient prescribing system. ARUSC is launched either by the physician to seek guidance for an infectious disease condition or via auto-trigger when restricted antibiotics are prescribed. This paper describes the implementation of ARUSC over three phases from 1 May 2011 to 30 April 2013, compared factors between ARUSC launches via auto-trigger and for guidance, examined factors associated with acceptance of ARUSC recommendations, and assessed user acceptability. During the study period, a monthly average of 9072 antibiotic prescriptions was made, of which 2370 (26.1%) involved ARUSC launches. Launches via auto-trigger comprised 48.1% of ARUSC launches. In phase 1, 23% of ARUSC launches were completed. This rose to 38% in phase 2, then 87% in phase 3, as escapes from the ARUSC programme were sequentially disabled. Amongst completed launches for guidance, 89% of ARUSC recommendations were accepted versus 40% amongst completed launches via auto-trigger. Amongst ARUSC launches for guidance, being from a medical department [adjusted odds ratio (aOR)=1.20, 95% confidence interval (CI) 1.04-1.37] and ARUSC launch during on-call (aOR=1.81, 95% CI 1.61-2.05) were independently associated with acceptance of ARUSC recommendations. Junior physicians found ARUSC useful. Senior physicians found ARUSC reliable but admitted to having preferences for antibiotics that may conflict with ARUSC. Hospital-wide implementation of ARUSC encountered hurdles from physicians. With modifications, the completion rate improved. Copyright © 2015 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.
Computers, the Internet and medical education in Africa.
Williams, Christopher D; Pitchforth, Emma L; O'Callaghan, Christopher
2010-05-01
OBJECTIVES This study aimed to explore the use of information and communications technology (ICT) in undergraduate medical education in developing countries. METHODS Educators (deans and heads of medical education) in English-speaking countries across Africa were sent a questionnaire to establish the current state of ICT at medical schools. Non-respondents were contacted firstly by e-mail, subsequently by two postal mailings at 3-month intervals, and finally by telephone. Main outcome measures included cross-sectional data about the availability of computers, specifications, Internet connection speeds, use of ICT by students, and teaching of ICT and computerised research skills, presented by country or region. RESULTS The mean computer : student ratio was 0.123. Internet speeds were rated as 'slow' or 'very slow' on a 5-point Likert scale by 25.0% of respondents overall, but by 58.3% in East Africa and 33.3% in West Africa (including Cameroon). Mean estimates showed that campus computers more commonly supported CD-ROM (91.4%) and sound (87.3%) than DVD-ROM (48.1%) and Internet (72.5%). The teaching of ICT and computerised research skills, and the use of computers by medical students for research, assignments and personal projects were common. CONCLUSIONS It is clear that ICT infrastructure in Africa lags behind that in other regions. Poor download speeds limit the potential of Internet resources (especially videos, sound and other large downloads) to benefit students, particularly in East and West (including Cameroon) Africa. CD-ROM capability is more widely available, but has not yet gained momentum as a means of distributing materials. Despite infrastructure limitations, ICT is already being used and there is enthusiasm for developing this further. Priority should be given to developing partnerships to improve ICT infrastructure and maximise the potential of existing technology.
2012-01-01
Background NICE recommends computerised cognitive behavioural therapy (cCBT) for the treatment of several mental health problems such as anxiety and depression. cCBT may be one way that services can reduce waiting lists and improve capacity and efficiency. However, there is some doubt about the extent to which the National Health Service (NHS) in the UK is embracing this new health technology in practice. This study aimed to investigate Scottish health service infrastructure and policies that promote or impede the implementation of cCBT in the NHS. Methods A telephone survey of lead IT staff at all health board areas across Scotland to systematically enquire about the ability of local IT infrastructure and IT policies to support delivery of cCBT. Results Overall, most of the health boards possess the required software to use cCBT programmes. However, the majority of NHS health boards reported that they lack dedicated computers for patient use, hence access to cCBT at NHS sites is limited. Additionally, local policy in the majority of boards prevent staff from routinely contacting patients via email, skype or instant messenger, making the delivery of short, efficient support sessions difficult. Conclusions Conclusions: Overall most of the infrastructure is in place but is not utilised in ways that allow effective delivery. For cCBT to be successfully delivered within a guided support model, as recommended by national guidelines, dedicated patient computers should be provided to allow access to online interventions. Additionally, policy should allow staff to support patients in convenient ways such as via email or live chat. These measures would increase the likelihood of achieving Scottish health service targets to reduce waiting time for psychological therapies to 18 weeks. PMID:22958309
Séroussi, B; Laouénan, C; Gligorov, J; Uzan, S; Mentré, F; Bouaud, J
2013-01-01
Background: Despite multidisciplinary tumour boards (MTBs), non-compliance with clinical practice guidelines is still observed for breast cancer patients. Computerised clinical decision support systems (CDSSs) may improve the implementation of guidelines, but cases of non-compliance persist. Methods: OncoDoc2, a guideline-based decision support system, has been routinely used to remind MTB physicians of patient-specific recommended care plans. Non-compliant MTB decisions were analysed using a multivariate adjusted logistic regression model. Results: Between 2007 and 2009, 1624 decisions for invasive breast cancers with a global non-compliance rate of 8.3% were analysed. Patient factors associated with non-compliance were age>80 years (odds ratio (OR): 7.7; 95% confidence interval (CI): 3.7–15.7) in pre-surgical decisions; microinvasive tumour (OR: 5.2; 95% CI: 1.5–17.5), surgical discovery of microinvasion in addition to a unique invasive tumour (OR: 4.2; 95% CI: 1.4–12.5), and prior neoadjuvant treatment (OR: 4.2; 95% CI: 1.1–15.1) in decisions with recommendation of re-excision; age<35 years (OR: 4.7; 95% CI: 1.9–11.4), positive hormonal receptors with human epidermal growth factor receptor 2 overexpression (OR: 15.7; 95% CI: 3.1–78.7), and the absence of prior axillary surgery (OR: 17.2; 95% CI: 5.1–58.1) in adjuvant decisions. Conclusion: Residual non-compliance despite the use of OncoDoc2 illustrates the need to question the clinical profiles where evidence is missing. These findings challenge the weaknesses of guideline content rather than the use of CDSSs. PMID:23942076
Implementing security in a distributed web-based EHCR.
Sucurovic, Snezana
2007-01-01
In many countries there are initiatives for building an integrated patient-centric electronic health record. There are also initiatives for transnational integrations. These growing demands for integration result from the fact that it can provide improving healthcare treatments and reducing the cost of healthcare services. While in European highly developed countries computerisation in healthcare sector began in the 1970s and reached a high level, some developing countries, and Serbia among them, have started computerisation recently. This is why MEDIS (MEDical Information System) is aimed at integration itself from the very beginning instead of integration of heterogeneous information systems on a middle layer or using HL7 protocol. The implementation of a national healthcare information system requires using standards as integrated and widely accepted solutions. Therefore, we have started building MEDIS to meet the requirements of CEN ENV 13606 and CEN ENV 13729 standards. The prototype version has a distributed component-based architecture with modern security solutions applied. MEDIS has been implemented as a federated system where the central server hosts basic EHCR information about a patient, and clinical servers contain their own part of patients' EHCR. At present, there is an initial version of prototype planned to be deployed at first in a small community. In particular, open source API for X.509 authentication and authorisation has been developed. Our project meets the requirements for education in health informatics, including appropriate knowledge and skills on EHCR. The points included in this article have been presented on several national conferences and widely discussed. MEDIS has explored a federated, component-based EHCR architecture and related security aspects. In its initial version it shows acceptable performances and administrative simplicity. It emphasizes the importance of using standards in building EHCR in our country, in order to prepare it for future integrations.
Schattner, Peter; Barker, Fiona; de Lusignan, Simon
2015-02-19
Minimally disruptive medicine (MDM) is proposed as a method for more appropriately managing people with multiple chronic disease. Much clinical management is currently single disease focussed, with people with multimorbidity being managed according to multiple single disease guidelines. Current initiatives to improve care include education about individual conditions and creating an environment where multiple guidelines might be simultaneously supported. The patient-centred medical home (PCMH) is an example of the latter. However, educational programmes and PCMH may increase the burden on patients. The cumulative workload for patients in managing the impact of multiple disease-specific guidelines is only relatively recently recognised. There is an intellectual vacuum as to how best to manage multimorbidity and how informatics might support implementing MDM. There is currently no alternative to multiple single-condition- specific guidelines and a lack of certainty, should the treatment burden need to be reduced, as to which guideline might be 'dropped'. The best information about multimorbidity is recorded in primary care computerised medical record (CMR) systems and in an increasing number of integrated care organisations. CMR systems have the potential to flag individuals who might be in greatest need. However, CMR systems may also provide insights into whether there are ameliorating factors that might make it easier for them to be resilient to the burden of care. Data from such CMR systems might be used to develop the evidence base about how to better manage multimorbidity. There is potential for these information systems to help reduce the management burden on patients and clinicians. However, substantial investment in research-driven CMR development is needed if we are to achieve this.
Hoermann, Simon; Ferreira Dos Santos, Luara; Morkisch, Nadine; Jettkowski, Katrin; Sillis, Moran; Devan, Hemakumar; Kanagasabai, Parimala S; Schmidt, Henning; Krüger, Jörg; Dohle, Christian; Regenbrecht, Holger; Hale, Leigh; Cutfield, Nicholas J
2017-07-01
New rehabilitation strategies for post-stroke upper limb rehabilitation employing visual stimulation show promising results, however, cost-efficient and clinically feasible ways to provide these interventions are still lacking. An integral step is to translate recent technological advances, such as in virtual and augmented reality, into therapeutic practice to improve outcomes for patients. This requires research on the adaptation of the technology for clinical use as well as on the appropriate guidelines and protocols for sustainable integration into therapeutic routines. Here, we present and evaluate a novel and affordable augmented reality system (Augmented Reflection Technology, ART) in combination with a validated mirror therapy protocol for upper limb rehabilitation after stroke. We evaluated components of the therapeutic intervention, from the patients' and the therapists' points of view in a clinical feasibility study at a rehabilitation centre. We also assessed the integration of ART as an adjunct therapy for the clinical rehabilitation of subacute patients at two different hospitals. The results showed that the combination and application of the Berlin Protocol for Mirror Therapy together with ART was feasible for clinical use. This combination was integrated into the therapeutic plan of subacute stroke patients at the two clinical locations where the second part of this research was conducted. Our findings pave the way for using technology to provide mirror therapy in clinical settings and show potential for the more effective use of inpatient time and enhanced recoveries for patients. Implications for Rehabilitation Computerised Mirror Therapy is feasible for clinical use Augmented Reflection Technology can be integrated as an adjunctive therapeutic intervention for subacute stroke patients in an inpatient setting Virtual Rehabilitation devices such as Augmented Reflection Technology have considerable potential to enhance stroke rehabilitation.
De Placido, S; De Angelis, C; Giuliano, M; Pizzi, C; Ruocco, R; Perrone, V; Bruzzese, D; Tommasielli, G; De Laurentiis, M; Cammarota, S; Arpino, G; Arpino, G
2017-03-14
Although guidelines do not recommend computerised tomography (CT), positron emission tomography (PET) or magnetic resonance imaging (MRI) for the staging or follow-up of asymptomatic patients with non-metastatic breast cancer, they are often requested in routine clinical practice. The aim of this study was to determine the staging and follow-up patterns, and relative costs in a large population of breast cancer patients living and treated in a Southern Italian region. We analysed the clinical computerised information recorded by 567 primary-care physicians assisting about 650 000 inhabitants in the Campania region. Patients with non-metastatic breast cancer were identified and divided into calendar years from 2001 to 2010. The number of diagnostic tests prescribed per 100 patients (N/Pts) and the mean cost per patient was determined 3 months before diagnosis and up to 1 year after diagnosis. Costs are expressed in constant 2011 euros. We identified 4680 newly diagnosed cases of asymptomatic non-metastatic breast cancer. N/Pts increased significantly (P<0.0001) from 2001 to 2010. The mean number of prescribed mammograms, bone scans, abdominal ultrasound and chest X-rays ('routine tests'), and costs was unchanged. However, the number of CT, PET scans and MRI ('new tests')prescriptions almost quadrupled and the mean cost per patient related to these procedures significantly increased from [euro ]357 in 2001 to [euro ]830 in 2010 (P<0.0001). New test prescriptions and relative costs significantly and steadily increased throughout the study period. At present there is no evidence that the delivery of new tests to asymptomatic patients improves breast cancer outcome. Well-designed clinical trials are urgently needed to shed light on the impact of these tests on clinical outcome and overall survival.
Structure-dependent performance of TiO 2/C as anode material for Na-ion batteries
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, Hanna; Gan, Qingmeng; Wang, Haiyan
The performance of energy storage materials is highly dependent on their nanostructures. Herein, hierarchical rod-in-tube TiO 2 with a uniform carbon coating is synthesized as the anode material for sodium-ion batteries by a facile solvothermal method. This unique structure consists of a tunable nanorod core, interstitial hollow spaces, and a functional nanotube shell assembled from two-dimensional nanosheets. By adjusting the types of solvents used and reaction time, the morphologies of TiO 2/C composites can be tuned to nanoparticles, microrods, rod-in-tube structures, or microtubes. Among these materials, rod-in-tube TiO 2 with a uniform carbon coating shows the highest electronic conductivity, specificmore » surface area (336.4 m(2) g(-1)), and porosity, and these factors lead to the best sodium storage capability. Benefiting from the unique structural features and improved electronic/ionic conductivity, the as-obtained rod-in-tube TiO2/C in coin cell tests exhibits a high discharge capacity of 277.5 and 153.9 mAh g(-1) at 50 and 5000 mA g(-1), respectively, and almost 100% capacity retention over 14,000 cycles at 5000 mA g(-1). In operando high-energy X-ray diffraction further confirms the stable crystal structure of the rod-in-tube TiO 2/C during Na+ insertion/extraction. This work highlights that nanostructure design is an effective strategy to achieve advanced energy storage materials.« less
Enhancing Discovery, Search, and Access of NASA Hydrological Data by Leveraging GEOSS
NASA Technical Reports Server (NTRS)
Teng, William L.
2015-01-01
An ongoing NASA-funded project has removed a longstanding barrier to accessing NASA data (i.e., accessing archived time-step array data as point-time series) for selected variables of the North American and Global Land Data Assimilation Systems (NLDAS and GLDAS, respectively) and other EOSDIS (Earth Observing System Data Information System) data sets (e.g., precipitation, soil moisture). These time series (data rods) are pre-generated. Data rods Web services are accessible through the CUAHSI Hydrologic Information System (HIS) and the Goddard Earth Sciences Data and Information Services Center (GES DISC) but are not easily discoverable by users of other non-NASA data systems. The Global Earth Observation System of Systems (GEOSS) is a logical mechanism for providing access to the data rods. An ongoing GEOSS Water Services project aims to develop a distributed, global registry of water data, map, and modeling services cataloged using the standards and procedures of the Open Geospatial Consortium and the World Meteorological Organization. The ongoing data rods project has demonstrated the feasibility of leveraging the GEOSS infrastructure to help provide access to time series of model grid information or grids of information over a geographical domain for a particular time interval. A recently-begun, related NASA-funded ACCESS-GEOSS project expands on these prior efforts. Current work is focused on both improving the performance of the generation of on-the-fly (OTF) data rods and the Web interfaces from which users can easily discover, search, and access NASA data.
Control rod driveline and grapple
Germer, John H.
1987-01-01
A control rod driveline and grapple is disclosed for placement between a control rod drive and a nuclear reactor control rod containing poison for parasitic neutron absorption required for reactor shutdown. The control rod is provided with an enlarged cylindrical handle which terminates in an upwardly extending rod to provide a grapple point for the driveline. The grapple mechanism includes a tension rod which receives the upwardly extending handle and is provided with a lower annular flange. A plurality of preferably six grapple segments surround and grip the control rod handle. Each grapple rod segment grips the flange on the tension rod at an interior upper annular indentation, bears against the enlarged cylindrical handle at an intermediate annulus and captures the upwardly flaring frustum shaped handle at a lower and complementary female segment. The tension rods and grapple segments are surrounded by and encased within a cylinder. The cylinder terminates immediately and outward extending annulus at the lower portion of the grapple segments. Excursion of the tension rod relative to the encasing cylinder causes rod release at the handle by permitting the grapple segments to pivot outwardly and about the annulus on the tension rod so as to open the lower defined frustum shaped annulus and drop the rod. Relative movement between the tension rod and cylinder can occur either due to electromagnetic release of the tension rod within defined limits of travel or differential thermal expansion as between the tension rod and cylinder as where the reactor exceeds design thermal limits.
The uses of cognitive training technologies in the treatment of autism spectrum disorders.
Wass, Sam V; Porayska-Pomsta, Kaska
2014-11-01
In this review, we focus on research that has used technology to provide cognitive training - i.e. to improve performance on some measurable aspect of behaviour - in individuals with autism spectrum disorders. We review technology-enhanced interventions that target three different cognitive domains: (a) emotion and face recognition, (b) language and literacy, and (c) social skills. The interventions reviewed allow for interaction through different modes, including point-and-click and eye-gaze contingent software, and are delivered through diverse implementations, including virtual reality and robotics. In each case, we examine the evidence of the degree of post-training improvement observed following the intervention, including evidence of transfer to altered behaviour in ecologically valid contexts. We conclude that a number of technological interventions have found that observed improvements within the computerised training paradigm fail to generalise to altered behaviour in more naturalistic settings, which may result from problems that people with autism spectrum disorders experience in generalising and extrapolating knowledge. However, we also point to several promising findings in this area. We discuss possible directions for future work. © The Author(s) 2013.
Cook, G A; Wald, N J
1985-09-30
We conducted a pilot study to assess the feasibility using the Electoral Register to carry out a cervical cancer screening programme on a Health District basis. A random sample of 500 names and addresses were drawn from a computerised list of the Electoral Register from three Electoral Wards in Oxford. A pilot study showed that the Electoral Register could be used successfully in this way and that the proportion of women aged 35-64 years who had a cervical smear examination as a result of the screening initiative was increased by a quarter, from 64% to 79%. The numbers of women involved at each step of the screening process were determined, and these may provide a useful guide to others considering implementing similar schemes.
The use of microtomography in bone tissue and biomaterial three-dimensional analysis.
Bedini, Rossella; Meleo, Deborah; Pecci, Raffaella; Pacifici, Luciano
2009-01-01
X-ray computed microtomography (micro-CT, microComputerised Tomography) is a miniaturized form of conventional computerized axial tomography (CAT ). This sophisticated technology enables 3D riconstruction of the internal structure of small X-ray opaque objects without sample destruction or preparation. The aim of this study is to show the possible applications of micro-CT in the analysis of bone graft materials of different origins (i.e. homologous, heterologous, alloplastic) in order to define their morphometric properties by means of SkyScan 1072 3D microtomography system. Since there is a close relationship between the properties of the materials and their microstructure, it is necessary to examine them using the highest levels of resolution before being able to improve existing materials or create new products.
Computerised Screening for Dyslexia in Adults
ERIC Educational Resources Information Center
Singleton, Chris; Horne, Joanna; Simmons, Fiona
2009-01-01
Identifying dyslexia in adulthood presents particular challenges because of complicating factors such as acquisition of compensatory strategies, differing degrees of intervention and the problem of distinguishing dyslexic adults from those whose literacy difficulties have non-cognitive causes. One of the implications is that conventional literacy…
Wavefront improvement in an end-pumped high-power Nd:YAG zigzag slab laser.
Shin, Jae Sung; Cha, Yong-Ho; Lim, Gwon; Kim, Yonghee; Kwon, Seong-Ouk; Cha, Byung Heon; Lee, Hyeon Cheor; Kim, Sangin; Koh, Kwang Uoong; Kim, Hyun Tae
2017-08-07
Techniques for wavefront improvement in an end-pumped Nd:YAG zigzag slab laser amplifier were proposed and demonstrated experimentally. First, a study on the contact materials was conducted to improve the heat transfer between the slab and cooling blocks and to increase the cooling uniformity. Among many attempts, only the use of silicon oil showed an improvement in the wavefront. Thus, the appropriate silicone oil was applied to the amplifier as a contact material. In addition, the wavefront compensation method using a glass rod array was also applied to the amplifier. A very low wavefront distortion was obtained through the use of a silicone-oil contact and glass rod array. The variance of the optical path difference for the entire beam height was 3.87 μm at a pump power of 10.6 kW, and that for the 80% section was 1.69 μm. The output power from the oscillator was 3.88 kW, which means the maximum output extracted from the amplifier at a pump power of 10.6 kW.
Stress analysis in a pedicle screw fixation system with flexible rods in the lumbar spine.
Kim, Kyungsoo; Park, Won Man; Kim, Yoon Hyuk; Lee, SuKyoung
2010-01-01
Breakage of screws has been one of the most common complications in spinal fixation systems. However, no studies have examined the breakage risk of pedicle screw fixation systems that use flexible rods, even though flexible rods are currently being used for dynamic stabilization. In this study, the risk of breakage of screws for the rods with various flexibilities in pedicle screw fixation systems is investigated by calculating the von Mises stress as a breakage risk factor using finite element analysis. Three-dimensional finite element models of the lumbar spine with posterior one-level spinal fixations at L4-L5 using four types of rod (a straight rod, a 4 mm spring rod, a 3 mm spring rod, and a 2 mm spring rod) were developed. The von Mises stresses in both the pedicle screws and the rods were analysed under flexion, extension, lateral bending, and torsion moments of 10 Nm with a follower load of 400 N. The maximum von Mises stress, which was concentrated on the neck region of the pedicle screw, decreased as the flexibility of the rod increased. However, the ratio of the maximum stress in the rod to the yield stress increased substantially when a highly flexible rod was used. Thus, the level of rod flexibility should be considered carefully when using flexible rods for dynamic stabilization because the intersegmental motion facilitated by the flexible rod results in rod breakage.
Elevated cAMP improves signal-to-noise ratio in amphibian rod photoreceptors
Govardovskii, Victor I.
2017-01-01
The absolute sensitivity of vertebrate retinas is set by a background noise, called dark noise, which originates from several different cell types and is generated by different molecular mechanisms. The major share of dark noise is produced by photoreceptors and consists of two components, discrete and continuous. Discrete noise is generated by spontaneous thermal activations of visual pigment. These events are undistinguishable from real single-photon responses (SPRs) and might be considered an equivalent of the signal. Continuous noise is produced by spontaneous fluctuations of the catalytic activity of the cGMP phosphodiesterase. This masks both SPR and spontaneous SPR-like responses. Circadian rhythms affect photoreceptors, among other systems by periodically increasing intracellular cAMP levels ([cAMP]in), which increases the size and changes the shape of SPRs. Here, we show that forskolin, a tool that increases [cAMP]in, affects the magnitude and frequency spectrum of the continuous and discrete components of dark noise in photoreceptors. By changing both components of rod signaling, the signal and the noise, cAMP is able to increase the photoreceptor signal-to-noise ratio by twofold. We propose that this results in a substantial improvement of signal detection, without compromising noise rejection, at the rod bipolar cell synapse. PMID:28611079
NASA Astrophysics Data System (ADS)
Luo, Lin
2017-08-01
In the practical selection of Wushu athletes, the objective evaluation of the level of athletes lacks sufficient technical indicators and often relies on the coach’s subjective judgments. It is difficult to accurately and objectively reflect the overall quality of the athletes without a fully quantified indicator system, thus affecting the level improvement of Wushu competition. The analytic hierarchy process (AHP) is a systemic analysis method combining quantitative and qualitative analysis. This paper realizes structured, hierarchized and quantified decision-making process of evaluating broadsword, rod, sword and spear athletes in the AHP. Combing characteristics of the athletes, analysis is carried out from three aspects, i.e., the athlete’s body shape, physical function and sports quality and 18 specific evaluation indicators established, and then combining expert advice and practical experience, pairwise comparison matrix is determined, and then the weight of the indicators and comprehensive evaluation coefficient are obtained to establish the evaluation model for the athletes, thus providing a scientific theoretical basis for the selection of Wushu athletes. The evaluation model proposed in this paper has realized the evaluation system of broadsword, rod, sword and spear athletes, which has effectively improved the scientific level of Wushu athletes selection in practical application.
Three Generations of FPGA DAQ Development for the ATLAS Pixel Detector
NASA Astrophysics Data System (ADS)
Mayer, Joseph A., II
The Large Hadron Collider (LHC) at the European Center for Nuclear Research (CERN) tracks a schedule of long physics runs, followed by periods of inactivity known as Long Shutdowns (LS). During these LS phases both the LHC, and the experiments around its ring, undergo maintenance and upgrades. For the LHC these upgrades improve their ability to create data for physicists; the more data the LHC can create the more opportunities there are for rare events to appear that physicists will be interested in. The experiments upgrade so they can record the data and ensure the event won't be missed. Currently the LHC is in Run 2 having completed the first LS of three. This thesis focuses on the development of Field-Programmable Gate Array (FPGA)-based readout systems that span across three major tasks of the ATLAS Pixel data acquisition (DAQ) system. The evolution of Pixel DAQ's Readout Driver (ROD) card is presented. Starting from improvements made to the new Insertable B-Layer (IBL) ROD design, which was part of the LS1 upgrade; to upgrading the old RODs from Run 1 to help them run more efficiently in Run 2. It also includes the research and development of FPGA based DAQs and integrated circuit emulators for the ITk upgrade which will occur during LS3 in 2025.
Chen, H; Ho, H M; Ying, M; Fu, S N
2012-01-01
Objectives The purpose of this study was to correlate findings on small vessel vascularity between computerised findings and Newman's scaling using power Doppler ultrasonography (PDU) imaging and its predictive value in patients with plantar fasciitis. Methods PDU was performed on 44 patients (age range 30–66 years; mean age 48 years) with plantar fasciitis and 46 healthy subjects (age range 18–61 years; mean age 36 years). The vascularity was quantified using ultrasound images by a customised software program and graded by Newman's grading scale. Vascular index (VI) was calculated from the software program as the ratio of the number of colour pixels to the total number of pixels within a standardised selected area of proximal plantar fascia. The 46 healthy subjects were examined on 2 occasions 7–10 days apart, and 18 of them were assessed by 2 examiners. Statistical analyses were performed using intraclass correlation coefficient and linear regression analysis. Results Good correlation was found between the averaged VI ratios and Newman's qualitative scale (ρ = 0.70; p<0.001). Intratester and intertester reliability were 0.89 and 0.61, respectively. Furthermore, higher VI was correlated with less reduction in pain after physiotherapeutic intervention. Conclusions The computerised VI not only has a high level of concordance with the Newman grading scale but is also reliable in reflecting the vascularity of proximal plantar fascia, and can predict pain reduction after intervention. This index can be used to characterise the changes in vascularity of patients with plantar fasciitis, and it may also be helpful for evaluating treatment and monitoring the progress after intervention in future studies. PMID:22167513
Computerised patient record with distributed objects.
Gornik, T; Orel, A; Roblek, D; Verhovsek, R
1999-01-01
The vast spectrum of information and functionality requirements imposed on a Computerised Patient Record (CPR), fueled by an ever changing and expanding business model demands information system interoperability. The management of information, created across the continuum of care, and associated information system functionality, can not be provided by data interchange to and from monolithic applications. WebDoctor is a Computerised Patient Record (CPR) which is fully used at the Institute of Oncology in Ljubljana, Slovenia--a hospital with 500 beds and more than 200 users, all of them medical professionals. The data are stored in an underlying Oracle hospital data base. For logging the username and password security is used. WebDoctor uses Internationalization APIs. Currently GUI is currently written in Slovenian language, but can be easily adapted to any other language. It is available in either Metal or Windows look. Search for patients is based on CPR No. or partial data from demographics. All the available patients data can be found on a single screen divided into several tab sections. The tab sections cover general and speciality data. The general data include demographics, admissions and diagnoses, meanwhile the speciality data are divided into Labs where data are represented numerically by date or by type and graphically with the ability of detailed view in separate window, Radiology where results are represented in textual form as well as pictures together with a special viewer to provide detailed analyses and Radioisotopes where results are also being represented in textual form together with a graphical representation. WebDoctor is running on virtually any platform. It achieved the 100% Java Certification which places the application among the firsts if not the first of this kind in the healthcare industry. It excels with a small and light client which doesn't exceed the 150K.
Chou, Cheng-Chen; Pressler, Susan J; Giordani, Bruno; Fetzer, Susan Jane
2015-11-01
To evaluate the validity of the Chinese version of the CogState battery, a computerised cognitive testing among patients with heart failure in Taiwan. Cognitive deficits are common in patients with heart failure and a validated Chinese measurement is required for assessing cognitive change for this population. The CogState computerised battery is a measurement of cognitive function and has been validated in many languages, but not Chinese. A cross-sectional study. A convenience sample consisted of 76 women with heart failure and 64 healthy women in northern Taiwan. Women completed the Chinese version of the CogState battery and the Montreal Cognitive Assessment. Construct validity of the Chinese version of the battery was evaluated by exploratory factor analysis and known-group comparisons. Convergent validity of the CogState tasks was examined by Pearson correlation coefficients. Principal components factor analysis with promax rotation showed two factors reflecting the speed and memory dimensions of the tests. Scores for CogState battery tasks showed significant differences between the heart failure and healthy control group. Examination of convergent validity of the CogState found a significant association with the Montreal Cognitive Assessment. The Chinese CogState Battery has satisfactory construct and convergent validity to measure cognitive deficits in patients with heart failure in Taiwan. The Chinese CogState battery is a valid instrument for detecting cognitive deficits that may be subtle in the early stages, and identifying changes that provide insights into patients' abilities to implement treatment accurately and consistently. Better interventions tailored to the needs of the cognitive impaired population can be developed. © 2015 John Wiley & Sons Ltd.
Fast SiPM Readout of the PANDA TOF Detector
NASA Astrophysics Data System (ADS)
Böhm, M.; Lehmann, A.; Motz, S.; Uhlig, F.
2016-05-01
For the identification of low momentum charged particles and for event timing purposes a barrel Time-of-Flight (TOF) detector surrounding the interaction point is planned for the PANDA experiment at FAIR . Since the boundary conditions in terms of available radial space and radiation length are quite strict the favored layout is a hodoscope composed of several thousand small scintillating tiles (SciTils) read out by silicon photomultipliers (SiPMs). A time resolution of well below 100 ps is aimed for. With the originally proposed 30 × 30 × 5 mm3 SciTils read out by two single 3 × 3 mm2 SiPMs at the rims of the scintillator the targeted time resolution can be just reached, but with a considerable position dependence across the scintillator surface. In this paper we discuss other design options to further improve the time resolution and its homogeneity. It will be shown that wide scintillating rods (SciRods) with a size of, e.g., 50 × 30 × 5 mm3 or longer and read out at opposite sides by a chain of four serially connected SiPMs a time resolution down to 50 ps can be reached without problems. In addition, the position dependence of the time resolution is negligible. These SciRods were tested in the laboratory with electrons of a 90Sr source and under real experimental conditions in a particle beam at CERN. The measured time resolutions using fast BC418 or BC420 plastic scintillators wrapped in aluminum foil were consistently between 45 and 75 ps dependent on the SciRod design. This is a significant improvement compared to the original SciTil layout.
Analysis of transient fission gas behaviour in oxide fuel using BISON and TRANSURANUS
NASA Astrophysics Data System (ADS)
Barani, T.; Bruschi, E.; Pizzocri, D.; Pastore, G.; Van Uffelen, P.; Williamson, R. L.; Luzzi, L.
2017-04-01
The modelling of fission gas behaviour is a crucial aspect of nuclear fuel performance analysis in view of the related effects on the thermo-mechanical performance of the fuel rod, which can be particularly significant during transients. In particular, experimental observations indicate that substantial fission gas release (FGR) can occur on a small time scale during transients (burst release). To accurately reproduce the rapid kinetics of the burst release process in fuel performance calculations, a model that accounts for non-diffusional mechanisms such as fuel micro-cracking is needed. In this work, we present and assess a model for transient fission gas behaviour in oxide fuel, which is applied as an extension of conventional diffusion-based models to introduce the burst release effect. The concept and governing equations of the model are presented, and the sensitivity of results to the newly introduced parameters is evaluated through an analytic sensitivity analysis. The model is assessed for application to integral fuel rod analysis by implementation in two structurally different fuel performance codes: BISON (multi-dimensional finite element code) and TRANSURANUS (1.5D code). Model assessment is based on the analysis of 19 light water reactor fuel rod irradiation experiments from the OECD/NEA IFPE (International Fuel Performance Experiments) database, all of which are simulated with both codes. The results point out an improvement in both the quantitative predictions of integral fuel rod FGR and the qualitative representation of the FGR kinetics with the transient model relative to the canonical, purely diffusion-based models of the codes. The overall quantitative improvement of the integral FGR predictions in the two codes is comparable. Moreover, calculated radial profiles of xenon concentration after irradiation are investigated and compared to experimental data, illustrating the underlying representation of the physical mechanisms of burst release.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barani, T.; Bruschi, E.; Pizzocri, D.
The modelling of fission gas behaviour is a crucial aspect of nuclear fuel analysis in view of the related effects on the thermo-mechanical performance of the fuel rod, which can be particularly significant during transients. Experimental observations indicate that substantial fission gas release (FGR) can occur on a small time scale during transients (burst release). To accurately reproduce the rapid kinetics of burst release in fuel performance calculations, a model that accounts for non-diffusional mechanisms such as fuel micro-cracking is needed. In this work, we present and assess a model for transient fission gas behaviour in oxide fuel, which ismore » applied as an extension of diffusion-based models to allow for the burst release effect. The concept and governing equations of the model are presented, and the effect of the newly introduced parameters is evaluated through an analytic sensitivity analysis. Then, the model is assessed for application to integral fuel rod analysis. The approach that we take for model assessment involves implementation in two structurally different fuel performance codes, namely, BISON (multi-dimensional finite element code) and TRANSURANUS (1.5D semi-analytic code). The model is validated against 19 Light Water Reactor fuel rod irradiation experiments from the OECD/NEA IFPE (International Fuel Performance Experiments) database, all of which are simulated with both codes. The results point out an improvement in both the qualitative representation of the FGR kinetics and the quantitative predictions of integral fuel rod FGR, relative to the canonical, purely diffusion-based models, with both codes. The overall quantitative improvement of the FGR predictions in the two codes is comparable. Furthermore, calculated radial profiles of xenon concentration are investigated and compared to experimental data, demonstrating the representation of the underlying mechanisms of burst release by the new model.« less
Modeling and simulation performance of sucker rod beam pump
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aditsania, Annisa, E-mail: annisaaditsania@gmail.com; Rahmawati, Silvy Dewi, E-mail: silvyarahmawati@gmail.com; Sukarno, Pudjo, E-mail: psukarno@gmail.com
2015-09-30
Artificial lift is a mechanism to lift hydrocarbon, generally petroleum, from a well to surface. This is used in the case that the natural pressure from the reservoir has significantly decreased. Sucker rod beam pumping is a method of artificial lift. Sucker rod beam pump is modeled in this research as a function of geometry of the surface part, the size of sucker rod string, and fluid properties. Besides its length, sucker rod string also classified into tapered and un-tapered. At the beginning of this research, for easy modeling, the sucker rod string was assumed as un-tapered. The assumption provedmore » non-realistic to use. Therefore, the tapered sucker rod string modeling needs building. The numerical solution of this sucker rod beam pump model is computed using finite difference method. The numerical result shows that the peak of polished rod load for sucker rod beam pump unit C-456-D-256-120, for non-tapered sucker rod string is 38504.2 lb, while for tapered rod string is 25723.3 lb. For that reason, to avoid the sucker rod string breaks due to the overload, the use of tapered sucker rod beam string is suggested in this research.« less
Brown, Benjamin; Balatsoukas, Panos; Williams, Richard; Sperrin, Matthew; Buchan, Iain
2016-10-01
Audit and Feedback (A&F) is a widely used quality improvement technique that measures clinicians' clinical performance and reports it back to them. Computerised A&F (e-A&F) system interfaces may consist of four key components: (1) Summaries of clinical performance; (2) Patient lists; (3) Patient-level data; (4) Recommended actions. There is a lack of evidence regarding how to best design e-A&F interfaces; establishing such evidence is key to maximising usability, and in turn improving patient safety. To evaluate the usability of a novel theoretically-informed and research-led e-A&F system for primary care (the Performance Improvement plaN GeneratoR: PINGR). (1) Describe PINGR's design, rationale and theoretical basis; (2) Identify usability issues with PINGR; (3) Understand how these issues may interfere with the cognitive goals of end-users; (4) Translate the issues into recommendations for the user-centred design of e-A&F systems. Eight experienced health system evaluators performed a usability inspection using an innovative hybrid approach consisting of five stages: (1) Development of representative user tasks, Goals, and Actions; (2) Combining Heuristic Evaluation and Cognitive Walkthrough methods into a single protocol to identify usability issues; (3) Consolidation of issues; (4) Severity rating of consolidated issues; (5) Analysis of issues according to usability heuristics, interface components, and Goal-Action structure. A final list of 47 issues were categorised into 8 heuristic themes. The most error-prone heuristics were 'Consistency and standards' (13 usability issues; 28% of the total) and 'Match between system and real world' (n=10, 21%). The recommended actions component of the PINGR interface had the most usability issues (n=21, 45%), followed by patient-level data (n=5, 11%), patient lists (n=4, 9%), and summaries of clinical performance (n=4, 9%). The most error-prone Actions across all user Goals were: (1) Patient selection from a list; (2) Data identification from a figure (both population-level and patient-level); (3) Disagreement with a system recommendation. By contextualising our findings within the wider literature on health information system usability, we provide recommendations for the design of e-A&F system interfaces relating to their four key components, in addition to how they may be integrated within a system. Copyright © 2016. Published by Elsevier Ireland Ltd.
So, Mirai; Yamaguchi, Sosei; Hashimoto, Sora; Sado, Mitsuhiro; Furukawa, Toshi A; McCrone, Paul
2013-04-15
Depression is a major cause of disability worldwide, and computerised cognitive behavioural therapy (CCBT) is expected to be a more augmentative and efficient treatment. According to previous meta-analyses of CCBT, there is a need for a meta-analytic revaluation of the short-term effectiveness of this therapy and for an evaluation of its long-term effects, functional improvement and dropout. Five databases were used (MEDLINE, PsycINFO, EMBASE, CENTRAL and CiNii). We included all RCTs with proper concealment and blinding of outcome assessment for the clinical effectiveness of CCBT in adults (aged 18 and over) with depression. Using Cohen's method, the standard mean difference (SMD) for the overall pooled effects across the included studies was estimated with a random effect model. The main outcome measure and the relative risk of dropout were included in the meta-analysis. Fourteen trials met the inclusion criteria, and sixteen comparisons from these were used for the largest meta-analysis ever. All research used appropriate random sequence generation and Intention-to-Treat analyses (ITT), and employed self-reported measures as the primary outcome. For the sixteen comparisons (2807 participants) comparing CCBT and control conditions, the pooled SMD was -0.48 [95% IC -0.63 to -0.33], suggesting similar effect to the past reviews. Also, there was no significant clinical effect at long follow-up and no improvement of function found. Furthermore, a significantly higher drop-out rate was found for CCBT than for controls. When including studies without BDI as a rating scale and with only modern imputation as sensitivity analysis, the pooled SMD remained significant despite the reduction from a moderate to a small effect. Significant publication bias was found in a funnel plot and on two tests (Begg's p = 0.09; Egger's p = 0.01). Using a trim and fill analysis, the SMD was -0.32 [95% CI -0.49 to -0.16]. Despite a short-term reduction in depression at post-treatment, the effect at long follow-up and the function improvement were not significant, with significantly high drop-out. Considering the risk of bias, our meta-analysis implied that the clinical usefulness of current CCBT for adult depression may need to be re-considered downwards in terms of practical implementation and methodological validity.
76 FR 61135 - Environmental Impact Statement: Theodore Francis Green Airport, Warwick, RI
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-03
... efficiency improvements at Theodore Francis Green Airport, in Warwick, Rhode Island. The ROD documents the... available for review during normal business hours at the following locations: FAA New England Region...
Raschke, Robert A; Groves, Robert H; Khurana, Hargobind S; Nikhanj, Nidhi; Utter, Ethel; Hartling, Didi; Stoffer, Brenda; Nunn, Kristina; Tryon, Shona; Bruner, Michelle; Calleja, Maria; Curry, Steven C
2017-01-01
Sepsis is a leading cause of mortality and morbidity in hospitalised patients. The Centers for Medicare and Medicaid Services (CMS) mandated that US hospitals report sepsis bundle compliance rate as a quality process measure in October 2015. The specific aim of our study was to improve the CMS sepsis bundle compliance rate from 30% to 40% across 20 acute care hospitals in our healthcare system within 1 year. The study included all adult inpatients with sepsis sampled according to CMS specifications from October 2015 to September 2016. The CMS sepsis bundle compliance rate was tracked monthly using statistical process control charting. A baseline rate of 28.5% with 99% control limits was established. We implemented multiple interventions including computerised decision support systems (CDSSs) to increase compliance with the most commonly missing bundle elements. Compliance reached 42% (99% statistical process control limits 18.4%-38.6%) as CDSS was implemented system-wide, but this improvement was not sustained after CMS changed specifications of the outcome measure. Difficulties encountered elucidate shortcomings of our study methodology and of the CMS sepsis bundle compliance rate as a quality process measure.
Four principles for user interface design of computerised clinical decision support systems.
Kanstrup, Anne Marie; Christiansen, Marion Berg; Nøhr, Christian
2011-01-01
The paper presents results from a design research project of a user interface (UI) for a Computerised Clinical Decision Support System (CDSS). The ambition has been to design Human-Computer Interaction (HCI) that can minimise medication errors. Through an iterative design process a digital prototype for prescription of medicine has been developed. This paper presents results from the formative evaluation of the prototype conducted in a simulation laboratory with ten participating physicians. Data from the simulation is analysed by use of theory on how users perceive information. The conclusion is a model, which sum up four principles of interaction for design of CDSS. The four principles for design of user interfaces for CDSS are summarised as four A's: All in one, At a glance, At hand and Attention. The model emphasises integration of all four interaction principles in the design of user interfaces for CDSS, i.e. the model is an integrated model which we suggest as a guide for interaction design when working with preventing medication errors.
Post-marketing surveillance of quinolones 1988-1990.
Davey, P G; McDonald, T; Lindsay, G
1991-04-01
It has been much easier to obtain original data on adverse drug reactions (ADR) of quinolones from the pharmaceutical industry than it was two years ago. This is to be welcomed and, as anticipated, the new data continue to suggest that the new 4-quinolones have an ADR profile which is very similar to that of other antimicrobials. Visual disturbance is not a prominent feature, in contrast to the ADR profile of nalidixic acid. Better definition of quinolone ADRs requires prospective study, and the results of a newly completed prescription event monitoring study are awaited with interest. The potential use of computerised databases and record linkage is examined, but at present the number of quinolone prescriptions is too small to assess documentation of serious but rare events such as convulsions. Physicians need to be aware of the limitations of current data on suspected ADRs. Further investment in computerised databases is required to satisfy the requirements for attributing causality of an event to a drug.
[Importance of an outpatient record in obstetric anesthesia].
Lanza, V; Mercadante, S; Pignataro, A; Guglielmo, L; Villari, P; Di Fiore, G; Sapio, M; De Michele, P; Vegna, G
1991-01-01
A computerised record was used to collect data following an anesthesiological check-up of pregnant women at approximately 30 weeks of pregnancy. The record was input onto a portable PC in the anesthesia outpatient clinic, memorized on disk (3.5") and then transferred onto a PC network (one PC for each operating theatre) for "real time" consultation of each patient's data. All pregnant women attending the antenatal clinico were also given a folder illustrating epidural anesthetic techniques. Seven hundred and nine outpatient visits have been performed over the past two years with a 62% utilisation ratio. The collection of data using a computerised system allows a rapid and efficacious system of communication to be set up among the membranes of the anesthesiological team, thus encouraging the use of epidural techniques during labour. The distribution of the folder also facilitated the task of the anesthetist who found that pregnant women visiting the anesthesia clinic were already familiar with the epidural technique.
Spencer, Elizabeth; Ferguson, Alison; Craig, Hugh; Colyvas, Kim; Hankey, Graeme J; Flicker, Leon
2015-02-01
Decline in linguistic function has been associated with decline in cognitive function in previous research. This research investigated the informativeness of written language samples of Australian men from the Health in Men's Study (HIMS) aged from 76 to 93 years using the Computerised Propositional Idea Density Rater (CPIDR 5.1). In total, 60,255 words in 1147 comments were analysed using a linear-mixed model for statistical analysis. Results indicated no relationship with education level (p = 0.79). Participants for whom English was not their first learnt language showed Propositional Idea Density (PD) scores slightly lower (0.018 per 1 word). Mean PD per 1 word for those for whom English was their first language for comments below 60 words was 0.494 and above 60 words 0.526. Text length was found to have an effect (p = <0.0001). The mean PD was higher than previously reported for men and lower than previously reported for a similar cohort for Australian women.
Britton, Charles L; D& #x27; Urso, Brian R; Chaum, Edward; Simpson, John T; Baba, Justin S; Ericson, M. Nance; Warmack, Robert J
2013-04-23
In one embodiment, the present invention provides a method of removing scar tissue from an eye that includes inserting a device including an array of micro-rods into an eye, wherein at least one glass micro-rod of the array of glass micro-rods includes a sharp feature; contacting a scar tissue with the array of micro-rods; and removing the array of micro-rods and the scar tissue from the eye. In another embodiment, the present invention provides a medical device for engaging a tissue including and an array of glass micro-rods, wherein at least one glass micro-rod of the array of glass micro-rods includes a sharp feature opposite a base of the array of glass micro-rods that is connected to the cannula, wherein the sharp feature of the at least one micro-rod is angled from a plane that is normal to a face of the base of the array of glass micro-rods.
Influence of implant rod curvature on sagittal correction of scoliosis deformity.
Salmingo, Remel Alingalan; Tadano, Shigeru; Abe, Yuichiro; Ito, Manabu
2014-08-01
Deformation of in vivo-implanted rods could alter the scoliosis sagittal correction. To our knowledge, no previous authors have investigated the influence of implanted-rod deformation on the sagittal deformity correction during scoliosis surgery. To analyze the changes of the implant rod's angle of curvature during surgery and establish its influence on sagittal correction of scoliosis deformity. A retrospective analysis of the preoperative and postoperative implant rod geometry and angle of curvature was conducted. Twenty adolescent idiopathic scoliosis patients underwent surgery. Average age at the time of operation was 14 years. The preoperative and postoperative implant rod angle of curvature expressed in degrees was obtained for each patient. Two implant rods were attached to the concave and convex side of the spinal deformity. The preoperative implant rod geometry was measured before surgical implantation. The postoperative implant rod geometry after surgery was measured by computed tomography. The implant rod angle of curvature at the sagittal plane was obtained from the implant rod geometry. The angle of curvature between the implant rod extreme ends was measured before implantation and after surgery. The sagittal curvature between the corresponding spinal levels of healthy adolescents obtained by previous studies was compared with the implant rod angle of curvature to evaluate the sagittal curve correction. The difference between the postoperative implant rod angle of curvature and normal spine sagittal curvature of the corresponding instrumented level was used to evaluate over or under correction of the sagittal deformity. The implant rods at the concave side of deformity of all patients were significantly deformed after surgery. The average degree of rod deformation Δθ at the concave and convex sides was 15.8° and 1.6°, respectively. The average preoperative and postoperative implant rod angle of curvature at the concave side was 33.6° and 17.8°, respectively. The average preoperative and postoperative implant rod angle of curvature at the convex side was 25.5° and 23.9°, respectively. A significant relationship was found between the degree of rod deformation and preoperative implant rod angle of curvature (r=0.60, p<.005). The implant rods at the convex side of all patients did not have significant deformation. The results indicate that the postoperative sagittal outcome could be predicted from the initial rod shape. Changes in implant rod angle of curvature may lead to over- or undercorrection of the sagittal curve. Rod deformation at the concave side suggests that corrective forces acting on that side are greater than the convex side. Copyright © 2014 Elsevier Inc. All rights reserved.
Nuclear reactor remote disconnect control rod coupling indicator
Vuckovich, Michael
1977-01-01
A coupling indicator for use with nuclear reactor control rod assemblies which have remotely disengageable couplings between the control rod and the control rod drive shaft. The coupling indicator indicates whether the control rod and the control rod drive shaft are engaged or disengaged. A resistive network, utilizing magnetic reed switches, senses the position of the control rod drive mechanism lead screw and the control rod position indicating tube, and the relative position of these two elements with respect to each other is compared to determine whether the coupling is engaged or disengaged.
Woo, Patrick C Y; Chung, Liliane M W; Teng, Jade L L; Tse, Herman; Pang, Sherby S Y; Lau, Veronica Y T; Wong, Vanessa W K; Kam, Kwok‐ling; Lau, Susanna K P; Yuen, Kwok‐Yung
2007-01-01
This study is the first study that provides useful guidelines to clinical microbiologists and technicians on the usefulness of full 16S rRNA sequencing, 5′‐end 527‐bp 16S rRNA sequencing and the existing MicroSeq full and 500 16S rDNA bacterial identification system (MicroSeq, Perkin‐Elmer Applied Biosystems Division, Foster City, California, USA) databases for the identification of all existing medically important anaerobic bacteria. Full and 527‐bp 16S rRNA sequencing are able to identify 52–63% of 130 Gram‐positive anaerobic rods, 72–73% of 86 Gram‐negative anaerobic rods and 78% of 23 anaerobic cocci. The existing MicroSeq databases are able to identify only 19–25% of 130 Gram‐positive anaerobic rods, 38% of 86 Gram‐negative anaerobic rods and 39% of 23 anaerobic cocci. These represent only 45–46% of those that should be confidently identified by full and 527‐bp 16S rRNA sequencing. To improve the usefulness of MicroSeq, bacterial species that should be confidently identified by full and/or 527‐bp 16S rRNA sequencing but not included in the existing MicroSeq databases should be included. PMID:17046845
Researches on Tie Rod Ends Lubricated by Grease with TiO2 and ZrO2 Nanoparticles
NASA Astrophysics Data System (ADS)
Wozniak, Marek; Siczek, Krzysztof; Kubiak, Przemysław; Jozwiak, Piotr; Siczek, Krystian
2018-05-01
The nanoparticles of some materials can be used successfully to improve tribological properties through decreasing both wear and friction borne out of contact between the contact surfaces of elements in different devices, particularly vehicles. Nanoparticles of TiO2 and ZrO2 were chosen as additives to the lithium grease lubricating the contact surfaces in tie rod ends. The object of study was the steel ball – the component of the tie rod end – mating with the polymer insert and lubricated with the pure lithium grease or containing the addition of pure TiO2, pure ZrO2 nanoparticles, with a 1%wt. Studies on friction were carried out using the tester allowing cyclical rotational motion and different loading of contact. Wear was investigated by driving a car, whose tie rod ends were analysed, on a fixed ‘eight’-shape track and with a fixed velocity pattern. The aim of the study was to obtain the values and waveforms of friction moment and wear versus cycles, loading and composition of lubricating grease. The waveforms of friction coefficient were obtained using the FEM model of the analysed contact zone. Based on the obtained waveforms, recommendations for the composition of additives for lithium grease were made.
Yazici, Muharrem; Emans, John
2009-08-01
Review of relevant literature including personal opinions. To review the current researches investigating the efficacy of growing rod and thoracic expansion techniques in the treatment of congenital spine deformity of young children, and to highlight the contrasting advantages and limitations in the fusionless treatment of progressive congenital scoliosis. Congenital scoliosis has the potential for severe spinal deformity and thoracic insufficiency syndrome (TIS). Conventional fusion treatments in children tend to shorten the spine further exacerbating trunk shortening and TIS. In the surgical treatment of congenital spinal deformities in young children, while reconstructing the spinal deformity, one should simultaneously pursue preserving the growth potential of the vertebrae, improving the volume, symmetry, and functions of the thorax, and protecting this improvement during the growth. Today, employed in the treatment of spinal deformities of young children, there are 2 deformity reconstruction methods serving these targets: Growing rod technique and vertical expandable prosthetic titanium rib (VEPTR) with or without expansion thoracostomy. Peer-reviewed research articles and major international meeting presentations were reviewed. Methods were compared in terms of advantages and limitations. The growing rod technique is a safe and reliable method in the treatment of congenital spine deformity of young children who present some flexibility in the anomalous segment, or when the congenital anomaly involves a vertebral segment too long for resection, or with compensating curve with structural pattern concomitant to the congenital deformity. Expansion thoracostomy and VEPTR are the appropriate choice for severe congenital spine deformity when a large amount of growth remains. Although ventilator dependence is significantly decreasing, thoracic volume and space available for the lung are increased after expansion thoracostomy and VEPTR. Growing rod technique should be used in patients where the primary problem is at the vertebral column. If the patient has rib fusions and/or TIS has developed, in other words, if the primary problem involves the thoracic cage, expansion thoracostomy and VEPTR should be an appropriate option.
Cairns, Andrew W; Bond, Raymond R; Finlay, Dewar D; Guldenring, Daniel; Badilini, Fabio; Libretti, Guido; Peace, Aaron J; Leslie, Stephen J
The 12-lead Electrocardiogram (ECG) has been used to detect cardiac abnormalities in the same format for more than 70years. However, due to the complex nature of 12-lead ECG interpretation, there is a significant cognitive workload required from the interpreter. This complexity in ECG interpretation often leads to errors in diagnosis and subsequent treatment. We have previously reported on the development of an ECG interpretation support system designed to augment the human interpretation process. This computerised decision support system has been named 'Interactive Progressive based Interpretation' (IPI). In this study, a decision support algorithm was built into the IPI system to suggest potential diagnoses based on the interpreter's annotations of the 12-lead ECG. We hypothesise semi-automatic interpretation using a digital assistant can be an optimal man-machine model for ECG interpretation. To improve interpretation accuracy and reduce missed co-abnormalities. The Differential Diagnoses Algorithm (DDA) was developed using web technologies where diagnostic ECG criteria are defined in an open storage format, Javascript Object Notation (JSON), which is queried using a rule-based reasoning algorithm to suggest diagnoses. To test our hypothesis, a counterbalanced trial was designed where subjects interpreted ECGs using the conventional approach and using the IPI+DDA approach. A total of 375 interpretations were collected. The IPI+DDA approach was shown to improve diagnostic accuracy by 8.7% (although not statistically significant, p-value=0.1852), the IPI+DDA suggested the correct interpretation more often than the human interpreter in 7/10 cases (varying statistical significance). Human interpretation accuracy increased to 70% when seven suggestions were generated. Although results were not found to be statistically significant, we found; 1) our decision support tool increased the number of correct interpretations, 2) the DDA algorithm suggested the correct interpretation more often than humans, and 3) as many as 7 computerised diagnostic suggestions augmented human decision making in ECG interpretation. Statistical significance may be achieved by expanding sample size. Copyright © 2017 Elsevier Inc. All rights reserved.
Ionic liquids-mediated interactions between nanorods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Zhou; Zhang, Fei; Huang, Jingsong
Surface forces mediated by room-temperature ionic liquids (RTILs) play an essential role in diverse applications including self-assembly, lubrication, and electrochemical energy storage. In this work, using molecular simulations we study the interactions between two nanorods immersed in model RTILs at rod-rod separations where both structural and double layer forces are important. The interaction force between neutral rods oscillates as the two rods approach each other, similar to the classical structural forces. Such oscillatory force originates from the density oscillation of RTILs near each rod and is affected by the packing constraints imposed by the neighboring rods. The oscillation period andmore » decay length of the oscillatory force are mainly dictated by the ion density distribution near isolated nanorods. When charges are introduced on the rods, the interaction force remains short-range and oscillatory, similar to the interactions between planar walls mediated by some protic RTILs reported earlier. Nevertheless, introducing net charges to the rods greatly changes the rod-rod interactions, e.g., by delaying the appearance of the first force trough and increasing the oscillation period and decay length of the interaction force. The oscillation period and decay length of the oscillatory force and free energy are commensurate with those of the space charge density near an isolated, charged rod. The free energy of rod-rod interactions reaches local minima (maxima) at rod-rod separations when the space charges near the two rods interfere constructively (destructively). Here, the insight on the short-range interactions between nanorods in RTILs helps guide the design of novel materials, e.g., crystalline ion gels based on rigid-rod polyanions and RTILs.« less
Ionic liquids-mediated interactions between nanorods
Yu, Zhou; Zhang, Fei; Huang, Jingsong; ...
2017-10-06
Surface forces mediated by room-temperature ionic liquids (RTILs) play an essential role in diverse applications including self-assembly, lubrication, and electrochemical energy storage. In this work, using molecular simulations we study the interactions between two nanorods immersed in model RTILs at rod-rod separations where both structural and double layer forces are important. The interaction force between neutral rods oscillates as the two rods approach each other, similar to the classical structural forces. Such oscillatory force originates from the density oscillation of RTILs near each rod and is affected by the packing constraints imposed by the neighboring rods. The oscillation period andmore » decay length of the oscillatory force are mainly dictated by the ion density distribution near isolated nanorods. When charges are introduced on the rods, the interaction force remains short-range and oscillatory, similar to the interactions between planar walls mediated by some protic RTILs reported earlier. Nevertheless, introducing net charges to the rods greatly changes the rod-rod interactions, e.g., by delaying the appearance of the first force trough and increasing the oscillation period and decay length of the interaction force. The oscillation period and decay length of the oscillatory force and free energy are commensurate with those of the space charge density near an isolated, charged rod. The free energy of rod-rod interactions reaches local minima (maxima) at rod-rod separations when the space charges near the two rods interfere constructively (destructively). Here, the insight on the short-range interactions between nanorods in RTILs helps guide the design of novel materials, e.g., crystalline ion gels based on rigid-rod polyanions and RTILs.« less
Hawke, Basil C.
1986-01-01
A control rod drive uses gravitational forces to insert one or more control rods upwardly into a reactor core from beneath the reactor core under emergency conditions. The preferred control rod drive includes a vertically movable weight and a mechanism operatively associating the weight with the control rod so that downward movement of the weight is translated into upward movement of the control rod. The preferred control rod drive further includes an electric motor for driving the control rods under normal conditions, an electrically actuated clutch which automatically disengages the motor during a power failure and a decelerator for bringing the control rod to a controlled stop when it is inserted under emergency conditions into a reactor core.
NASA Technical Reports Server (NTRS)
Sellereite, B. K.; Waterman, A. W.; Nelson, W. G.
1974-01-01
Polyimide second-stage rod seals were evaluated to determine their suitability for applications in space station environments. The 6.35-cm (2.5-in.)K-section seal was verified for thermal cycling operation between room temperature and 478 K (400 F) and for operation in a 133 micron PA(0.000001 mm Hg) vacuum environment. The test seal completed the scheduled 96 thermal cycles and 1438 hr in vacuum with external rod seal leakage well within the maximum allowable of two drops per 25 actuation cycles. At program completion, the seals showed no signs of structural degradation. Posttest inspection showed the seals retained a snug fit against the shaft and housing walls, indicating additional wear life capability. Evaluation of a molecular flow section during vacuum testing, to inhibit fluid loss through vaporization, showed it to be beneficial with MIL-H-5606, a petroleum-base fluid, in comparison with MIL-H-83282, a synthetic hydrocarbon-base fluid.
Highly efficient solar-pumped Nd:YAG laser.
Liang, Dawei; Almeida, Joana
2011-12-19
The recent progress in solar-pumped laser with Fresnel lens and Cr:Nd:YAG ceramic medium has revitalized solar laser researches, revealing a promising future for renewable reduction of magnesium from magnesium oxide. Here we show a big advance in solar laser collection efficiency by utilizing an economical Fresnel lens and a most widely used Nd:YAG single-crystal rod. The incoming solar radiation from the sun is focused by a 0.9 m diameter Fresnel lens. A dielectric totally internally reflecting secondary concentrator is employed to couple the concentrated solar radiation from the focal zone to a 4 mm diameter Nd:YAG rod within a conical pumping cavity. 12.3 W cw laser power is produced, corresponding to 19.3 W/m(2) collection efficiency, which is 2.9 times larger than the previous results with Nd:YAG single-crystal medium. Record-high slope efficiency of 3.9% is also registered. Laser beam quality is considerably improved by pumping a 3 mm diameter Nd:YAG rod.
NASA Astrophysics Data System (ADS)
Hasegawa, Kazuo; Ichikawa, Tadashi; Takeda, Yasuhiko; Ikesue, Akio; Ito, Hiroshi; Motohiro, Tomoyoshi
2018-04-01
We have proposed a new configuration of solar-pumped lasers employing transparent ceramic rods. The laser rod has a composite structure consisting of a Nd/Cr:YAG gain domain surrounded by Gd:YAG with the same refractive index as that of Nd/Cr:YAG. The lasing mode is well controlled by the output coupler, and the parasitic oscillation is suppressed, owing to the refractive index matching. A high laser slope efficiency and a low laser oscillation threshold were achieved owing to the suppressed absorption outside the lasing mode, which was previously a serious issue for the end-pumping configuration using a high-NA focusing optics. The laser oscillation threshold of 136 mW and the slope efficiency of 25.3% were derived. Thus, we have resolved the issue of useless absorption associated with the high-NA end-pumping, and achieved significant improvements compared with the conventional structure of uniform Nd/Cr:YAG.
NASA Astrophysics Data System (ADS)
Labin, Amichai M.; Safuri, Shadi K.; Ribak, Erez N.; Perlman, Ido
2014-07-01
Vision starts with the absorption of light by the retinal photoreceptors—cones and rods. However, due to the ‘inverted’ structure of the retina, the incident light must propagate through reflecting and scattering cellular layers before reaching the photoreceptors. It has been recently suggested that Müller cells function as optical fibres in the retina, transferring light illuminating the retinal surface onto the cone photoreceptors. Here we show that Müller cells are wavelength-dependent wave-guides, concentrating the green-red part of the visible spectrum onto cones and allowing the blue-purple part to leak onto nearby rods. This phenomenon is observed in the isolated retina and explained by a computational model, for the guinea pig and the human parafoveal retina. Therefore, light propagation by Müller cells through the retina can be considered as an integral part of the first step in the visual process, increasing photon absorption by cones while minimally affecting rod-mediated vision.
Morphological Diversity of the Rod Spherule: A Study of Serially Reconstructed Electron Micrographs
Li, Shuai; Mitchell, Joe; Briggs, Deidrie J.; Young, Jaime K.; Long, Samuel S.; Fuerst, Peter G.
2016-01-01
Purpose Rod spherules are the site of the first synaptic contact in the retina’s rod pathway, linking rods to horizontal and bipolar cells. Rod spherules have been described and characterized through electron micrograph (EM) and other studies, but their morphological diversity related to retinal circuitry and their intracellular structures have not been quantified. Most rod spherules are connected to their soma by an axon, but spherules of rods on the surface of the Mus musculus outer plexiform layer often lack an axon and have a spherule structure that is morphologically distinct from rod spherules connected to their soma by an axon. Retraction of the rod axon and spherule is often observed in disease processes and aging, and the retracted rod spherule superficially resembles rod spherules lacking an axon. We hypothesized that retracted spherules take on an axonless spherule morphology, which may be easier to maintain in a diseased state. To test our hypothesis, we quantified the spatial organization and subcellular structures of rod spherules with and without axons. We then compared them to the retracted spherules in a disease model, mice that overexpress Dscam (Down syndrome cell adhesion molecule), to gain a better understanding of the rod synapse in health and disease. Methods We reconstructed serial EM images of wild type and DscamGoF (gain of function) rod spherules at a resolution of 7 nm in the X-Y axis and 60 nm in the Z axis. Rod spherules with and without axons, and retracted spherules in the DscamGoF retina, were reconstructed. The rod spherule intracellular organelles, the invaginating dendrites of rod bipolar cells and horizontal cell axon tips were also reconstructed for statistical analysis. Results Stereotypical rod (R1) spherules occupy the outer two-thirds of the outer plexiform layer (OPL), where they present as spherical terminals with large mitochondria. This spherule group is highly uniform and composed more than 90% of the rod spherule population. Rod spherules lacking an axon (R2) were also described and characterized. This rod spherule group consists of a specific spatial organization that is strictly located at the apical OPL-facing layer of the Outer Nuclear Layer (ONL). The R2 spherule displays a large bowl-shaped synaptic terminal that hugs the rod soma. Retracted spherules in the DscamGoF retina were also reconstructed to test if they are structurally similar to R2 spherules. The misplaced rod spherules in DscamGoF have a gross morphology that is similar to R2 spherules but have significant disruption in internal synapse organization. Conclusion We described a morphological diversity within Mus musculus rod spherules. This diversity is correlated with rod location in the ONL and contributes to the intracellular differences within spherules. Analysis of the DscamGoF retina indicated that their R2 spherules are not significantly different than wild type R2 spherules, but that their retracted rod spherules have abnormal synaptic organization. PMID:26930660
Morphological Diversity of the Rod Spherule: A Study of Serially Reconstructed Electron Micrographs.
Li, Shuai; Mitchell, Joe; Briggs, Deidrie J; Young, Jaime K; Long, Samuel S; Fuerst, Peter G
2016-01-01
Rod spherules are the site of the first synaptic contact in the retina's rod pathway, linking rods to horizontal and bipolar cells. Rod spherules have been described and characterized through electron micrograph (EM) and other studies, but their morphological diversity related to retinal circuitry and their intracellular structures have not been quantified. Most rod spherules are connected to their soma by an axon, but spherules of rods on the surface of the Mus musculus outer plexiform layer often lack an axon and have a spherule structure that is morphologically distinct from rod spherules connected to their soma by an axon. Retraction of the rod axon and spherule is often observed in disease processes and aging, and the retracted rod spherule superficially resembles rod spherules lacking an axon. We hypothesized that retracted spherules take on an axonless spherule morphology, which may be easier to maintain in a diseased state. To test our hypothesis, we quantified the spatial organization and subcellular structures of rod spherules with and without axons. We then compared them to the retracted spherules in a disease model, mice that overexpress Dscam (Down syndrome cell adhesion molecule), to gain a better understanding of the rod synapse in health and disease. We reconstructed serial EM images of wild type and DscamGoF (gain of function) rod spherules at a resolution of 7 nm in the X-Y axis and 60 nm in the Z axis. Rod spherules with and without axons, and retracted spherules in the DscamGoF retina, were reconstructed. The rod spherule intracellular organelles, the invaginating dendrites of rod bipolar cells and horizontal cell axon tips were also reconstructed for statistical analysis. Stereotypical rod (R1) spherules occupy the outer two-thirds of the outer plexiform layer (OPL), where they present as spherical terminals with large mitochondria. This spherule group is highly uniform and composed more than 90% of the rod spherule population. Rod spherules lacking an axon (R2) were also described and characterized. This rod spherule group consists of a specific spatial organization that is strictly located at the apical OPL-facing layer of the Outer Nuclear Layer (ONL). The R2 spherule displays a large bowl-shaped synaptic terminal that hugs the rod soma. Retracted spherules in the DscamGoF retina were also reconstructed to test if they are structurally similar to R2 spherules. The misplaced rod spherules in DscamGoF have a gross morphology that is similar to R2 spherules but have significant disruption in internal synapse organization. We described a morphological diversity within Mus musculus rod spherules. This diversity is correlated with rod location in the ONL and contributes to the intracellular differences within spherules. Analysis of the DscamGoF retina indicated that their R2 spherules are not significantly different than wild type R2 spherules, but that their retracted rod spherules have abnormal synaptic organization.
A Transformational Process: Facilitating WebQuests
ERIC Educational Resources Information Center
LoParrino, Camille A.
2005-01-01
Challenged by our 7th U.S. Secretary of Education, Rod Paige, when he said "Dream how technology can not only improve education but also transform what we think of as education," we made this dream a reality in an elementary classroom in the Bronx. The dream of improving and transforming education through technology became possible as a…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-19
... DEPARTMENT OF COMMERCE International Trade Administration [C-533-856] Steel Threaded Rod From... exporters of steel threaded rod from India. The period of investigation (``POI'') is January 1, 2012... this investigation is steel threaded rod. Steel threaded rod is certain threaded rod, bar, or studs, of...
Wang, Nanxiang; Xie, Huanxin; Xi, Chunyang; Zhang, Han; Yan, Jinglong
2017-03-09
The benefits of posterior lumbar fusion surgery with orthotopic paraspinal muscle-pediculated bone flaps are well established. However, the problem of non-union due to mechanical support is not completely resolved. The aim of the study was to compare the efficacy of polyether ether ketone (PEEK) rod device with conventional titanium devices in the posterior lumbar fusion surgery with orthotopic paraspinal muscle-pediculated bone flaps. This was a randomized controlled study with an experimental animal model. Thirty-two mongrel dogs were randomly divided into two groups-control group (n = 16), which received the titanium device and the treatment group (n = 16), which received PEEK rods. The animals were sacrificed 8 or 16 weeks after surgery. Lumbar spines of dogs in both groups were removed, harvested, and assessed for radiographic, biomechanical, and histological changes. Results in the current study indicated that there was no significant difference in the lumbar spine of the control and treatment groups in terms of radiographic, manual palpation, and gross examination. However, certain parameters of biomechanical testing showed significant differences (p < 0.05) in stiffness and displacement, revealing a better fusion (treatment group showed decreased stiffness with decreased displacement) of the bone graft. Similarly, the histological analysis also revealed a significant fusion mass in both treatment and control groups (p < 0.05). These findings revealed that fixation using PEEK connecting rod could improve the union of the bone graft in the posterior lumbar spine fusion surgery compared with that of the titanium rod fixation.
Method of preparing composite superconducting wire
Verhoeven, John D.; Gibson, Edwin D.; Finnemore, Douglas K.; Ostenson, Jerome E.; Schmidt, Frederick A.; Owen, Charles V.
1985-08-06
An improved method of preparing composite multifilament superconducting wire of Nb.sub.3 Sn in a copper matrix which eliminates the necessity of coating the drawn wire with tin. A generalized cylindrical billet of an alloy of copper containing at least 15 weight percent niobium, present in the copper as discrete, randomly distributed and oriented dendritic-shaped particles, is provided with at least one longitudinal opening which is filled with tin to form a composite drawing rod. The drawing rod is then drawn to form a ductile composite multifilament wire containing a filament of tin. The ductile wire containing the tin can then be wound into magnet coils or other devices before heating to diffuse the tin through the wire to react with the niobium forming Nb.sub.3 Sn. Also described is an improved method for making large billets of the copper-niobium alloy by consumable-arc casting.
Improvement of foam breaking and oxygen-transfer performance in a stirred-tank fermenter.
Takesono, Satoshi; Onodera, Masayuki; Toda, Kiyoshi; Yoshida, Masanori; Yamagiwa, Kazuaki; Ohkawa, Akira
2006-03-01
This study examined a stirred-tank fermenter (STF) containing low-viscosity foaming liquids with an agitation impeller and foam-breaking impeller mounted on the same shaft. Results showed that the performance of the foam-breaking impeller can be improved by changing a conventional six-blade turbine impeller into a rod impeller as the agitation impeller. The volumetric oxygen-transfer coefficient, kLa, in the mechanical foam-control method (MFM) using a six-blade vaned disk as the foam-breaking impeller in the STF with the rod impeller was approximately five times greater than that of the chemical foam-control method (CFM) adding an anti-foaming agent in the STF with the six-blade turbine impeller. Application of the present method to the cultivation of Saccharomyces cerevisiae K-7 demonstrated that the cultivation time up to the maximum cell concentration was remarkably shorter than that achieved using a conventional CFM.
A Computerised English Language Proofing Cloze Program.
ERIC Educational Resources Information Center
Coniam, David
1997-01-01
Describes a computer program that takes multiple-choice cloze passages and compiles them into proofreading exercises. Results reveal that such a computerized test type can be used to accurately measure the proficiency of students of English as a Second Language in Hong Kong. (14 references) (Author/CK)
The Experience of External Studies. Occasional Papers No. 4.
ERIC Educational Resources Information Center
Riverina Coll. of Advanced Education, Wagga Wagga, New South Wales (Australia).
This document brings together four invited papers by external students who have graduated from Riverina College: (1) "The External Student: One Profile" (Christine Del Gigante); (2) "Managing Life as a External Student" (Robert Landow); (3) "The Computerised Student" (John Chant); and (4) "The Right to…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tamburello, David A.; McWilliams, Anthony J.; Hardy, Bruce J.
Vessel assemblies, heat transfer units for prefabricated vessels, and methods for heat transfer prefabricated vessel are provided. A heat transfer unit includes a central rod, and a plurality of peripheral rods surrounding the central rod and connected to the central rod. The plurality of peripheral rods are movable between a first collapsed position and a second bowed position, wherein in the second bowed position a midpoint of each of the plurality of peripheral rods is spaced from the central rod relative to in the first position. The heat transfer unit further includes a heat transfer element connected to one ofmore » the plurality of peripheral rods.« less
Miao, Haixiong; Ye, Dongping; Liang, Weiguo; Yao, Yicun
2015-01-01
The conventional CD used 10 mm drill holes associated with a lack of structural support. Thus, alternative methods such as a tantalum implant, small drill holes, and biological treatment were developed to prevent deterioration of the joint. The treatment of CD by multiple 3.2 mm drill holes could reduce the femoral neck fracture and partial weight bearing was allowed. This study was aimed to evaluate the effect of osteonecrosis intervention rod versus core decompression using multiple small drill holes on early stages of necrosis of the femoral head. From January 2011 to January 2012, 60 patients undergoing surgery for osteonecrosis with core decompression were randomly assigned into 2 groups based on the type of core decompression used: (1) a total of 30 osteonecrosis patients (with 16 hips on Steinburg stageⅠ,20 hips on Steinburg stageⅡ) were treated with a porous tantalum rod insertion. The diameter of the drill hole for the intervention rod was 10mm.(2) a total of 30 osteonecrosis patients (with 14 hips on Steinburg stageⅠ,20 hips on Steinburg stageⅡ) were treated with core decompression using five drill holes on the lateral femur, the diameter of the hole was 3.2 mm. The average age of the patient was 32.6 years (20-45 years) and the average time of follow-up was 25.6 months (12- 28 months) in the rod implanted group. The average age of the patient was 35.2 years (22- 43 years) and the average time of follow-up was 26.3 months (12-28 months) in the small drill holes group. The average of surgical time was 40 min, and the mean volume of blood loss was 30 ml in both surgical groups. The average of Harris score was improved from 56.2 ± 7.1 preoperative to 80.2 ± 11.4 at the last follow-up in the rod implanted group (p < 0.05). The mean Harris score was improved from 53.8 ± 6.6 preoperative to 79.7 ± 13.2 at the last follow-up in the small drill holes group (p<0. 05). No significant difference was observed in Harris score between the two groups. At the last follow-up, 28 of 36 hips were at the same radiographic stages as pre-operation, and 8 deteriorated in the rod implanted group. 26 of 34 hips were at the same radiographic stage as pre-operation, and 8 deteriorated in the small drill holes group. No significant difference was observed in radiographic stage between the two groups. There was no favourable result on the outcome of a tantalum intervention implant compared to multiple small drill holes. CD via multiple small drill holes would allow similar postoperative load-bearing and seems to result in similar or even better clinical outcome without the prolonged implantation of an expensive tantalum implant. A tantalum rod intervention and core decompression using multiple small drill holes were effective on the stage I hips rather than stage II hips.
Salmingo, Remel Alingalan; Tadano, Shigeru; Abe, Yuichiro; Ito, Manabu
2016-05-12
Treatment for severe scoliosis is usually attained when the scoliotic spine is deformed and fixed by implant rods. Investigation of the intraoperative changes of implant rod shape in three-dimensions is necessary to understand the biomechanics of scoliosis correction, establish consensus of the treatment, and achieve the optimal outcome. The objective of this study was to measure the intraoperative three-dimensional geometry and deformation of implant rod during scoliosis corrective surgery.A pair of images was obtained intraoperatively by the dual camera system before rotation and after rotation of rods during scoliosis surgery. The three-dimensional implant rod geometry before implantation was measured directly by the surgeon and after surgery using a CT scanner. The images of rods were reconstructed in three-dimensions using quintic polynomial functions. The implant rod deformation was evaluated using the angle between the two three-dimensional tangent vectors measured at the ends of the implant rod.The implant rods at the concave side were significantly deformed during surgery. The highest rod deformation was found after the rotation of rods. The implant curvature regained after the surgical treatment.Careful intraoperative rod maneuver is important to achieve a safe clinical outcome because the intraoperative forces could be higher than the postoperative forces. Continuous scoliosis correction was observed as indicated by the regain of the implant rod curvature after surgery.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-20
... Steel Wire Rod From Mexico: Affirmative Preliminary Determination of Circumvention of the Antidumping.... SUMMARY: We preliminarily determine that carbon and certain alloy steel wire rod (wire rod) with an actual.... de C.V. (Deacero) is circumventing the antidumping duty order on wire rod from Mexico (Wire Rod Order...
La Barbera, Luigi; Brayda-Bruno, Marco; Liebsch, Christian; Villa, Tomaso; Luca, Andrea; Galbusera, Fabio; Wilke, Hans-Joachim
2018-05-08
To investigate the effect of anterior interbody cages, accessory and satellite rods usage on primary stability and rod strains for PSO stabilization. Seven human cadaveric spine segments (T12-S1) underwent PSO at L4 with posterior fixation from L2 to S1. In vitro flexibility tests were performed under pure moments in flexion/extension (FE), lateral bending (LB) and axial rotation (AR) to determine the range of motion, while measuring the strains on the primary rods with strain gauge rosettes. Six constructs with 2, 3 and 4 rods, with and without interbody cages implantation adjacent to the PSO site, were compared. All constructs had comparable effects in reducing spine kinematics compared to the intact condition (- 94% in FE and LB; - 80% in AR). Supplementation of 2 rods with lateral accessory rods (4 rods) was the most effective strategy in minimizing primary rod strains, particularly when coupled to cages (p ≤ 0.005; - 50% in FE, - 42% in AR and - 11% in LB); even without cages, the strains were significantly reduced (p ≤ 0.009; - 26%, - 37%, - 9%). The addition of a central satellite rod with laminar hooks (3 rods) effectively reduced rod strains in FE (p ≤ 0.005; - 30%) only in combination with cages. The study supports the current clinical practice providing a strong biomechanical rationale to recommend 4-rod constructs based on accessory rods combined with cages adjacent to PSO site. Although weaker, the usage of accessory rods without cages and of a central satellite rod with hooks in combination with interbody spacers may also be justified. These slides can be retrieved under Electronic Supplementary Material.
Conidial Hydrophobins of Aspergillus fumigatus
Paris, Sophie; Debeaupuis, Jean-Paul; Crameri, Reto; Carey, Marilyn; Charlès, Franck; Prévost, Marie Christine; Schmitt, Christine; Philippe, Bruno; Latgé, Jean Paul
2003-01-01
The surface of Aspergillus fumigatus conidia, the first structure recognized by the host immune system, is covered by rodlets. We report that this outer cell wall layer contains two hydrophobins, RodAp and RodBp, which are found as highly insoluble complexes. The RODA gene was previously characterized, and ΔrodA conidia do not display a rodlet layer (N. Thau, M. Monod, B. Crestani, C. Rolland, G. Tronchin, J. P. Latgé, and S. Paris, Infect. Immun. 62:4380-4388, 1994). The RODB gene was cloned and disrupted. RodBp was highly homologous to RodAp and different from DewAp of A. nidulans. ΔrodB conidia had a rodlet layer similar to that of the wild-type conidia. Therefore, unlike RodAp, RodBp is not required for rodlet formation. The surface of ΔrodA conidia is granular; in contrast, an amorphous layer is present at the surface of the conidia of the ΔrodA ΔrodB double mutant. These data show that RodBp plays a role in the structure of the conidial cell wall. Moreover, rodletless mutants are more sensitive to killing by alveolar macrophages, suggesting that RodAp or the rodlet structure is involved in the resistance to host cells. PMID:12620846
Surface properties of sprayed and electrodeposited ZnO rod layers
NASA Astrophysics Data System (ADS)
Gromyko, I.; Krunks, M.; Dedova, T.; Katerski, A.; Klauson, D.; Oja Acik, I.
2017-05-01
Herein we present a comparative study on as-deposited, two-month-stored, and heat-treated ZnO rods obtained by spray pyrolysis (SP) at 550 °C, and electrodeposition (ED) at 80 °C. The aim of the study is to establish the reason for different behaviour of wettability and photocatalytic activity (PA) of SP and ED rods. Samples were studied using XPS, SEM, XRD, Raman, contact angle (CA) measurements and photocatalytic oxidation of doxycycline. Wettability and PA are mainly controlled by surface composition rather than by morphology. The relative amount of hydroxyl groups on the surface of as-deposited ED rods is four times higher compared to as-deposited SP rods. Opposite to SP rods, ED rods contain oxygen vacancy defects (Vo). Therefore, as-deposited ED rods are superhydrophilic (CA ∼ 3°) and show highest PA among studied samples, being three times higher compared to SP rods (removing of 75% of doxycycline after 30 min). It was revealed that as-deposited ED rods are inclined to faster contamination. The amount of Cdbnd C groups on the surface of aged ED rods is six times higher compared to aged SP rods. Stored ED samples become hydrophobic (CA ∼ 120°) and PA decreases sharply while SP rods remain hydrophilic (CA ∼ 50°), being more resistive to the contamination.
"Building" 3D visualization skills in mineralogy
NASA Astrophysics Data System (ADS)
Gaudio, S. J.; Ajoku, C. N.; McCarthy, B. S.; Lambart, S.
2016-12-01
Studying mineralogy is fundamental for understanding the composition and physical behavior of natural materials in terrestrial and extraterrestrial environments. However, some students struggle and ultimately get discouraged with mineralogy course material because they lack well-developed spatial visualization skills that are needed to deal with three-dimensional (3D) objects, such as crystal forms or atomic-scale structures, typically represented in two-dimensional (2D) space. Fortunately, spatial visualization can improve with practice. Our presentation demonstrates a set of experiential learning activities designed to support the development and improvement of spatial visualization skills in mineralogy using commercially available magnetic building tiles, rods, and spheres. These instructional support activities guide students in the creation of 3D models that replicate macroscopic crystal forms and atomic-scale structures in a low-pressure learning environment and at low cost. Students physically manipulate square and triangularly shaped magnetic tiles to build 3D open and closed crystal forms (platonic solids, prisms, pyramids and pinacoids). Prismatic shapes with different closing forms are used to demonstrate the relationship between crystal faces and Miller Indices. Silica tetrahedra and octahedra are constructed out of magnetic rods (bonds) and spheres (oxygen atoms) to illustrate polymerization, connectivity, and the consequences for mineral formulae. In another activity, students practice the identification of symmetry elements and plane lattice types by laying magnetic rods and spheres over wallpaper patterns. The spatial visualization skills developed and improved through our experiential learning activities are critical to the study of mineralogy and many other geology sub-disciplines. We will also present pre- and post- activity assessments that are aligned with explicit learning outcomes.
Experimental Study of Two Phase Flow Behavior Past BWR Spacer Grids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ratnayake, Ruwan K.; Hochreiter, L.E.; Ivanov, K.N.
2002-07-01
Performance of best estimate codes used in the nuclear industry can be significantly improved by reducing the empiricism embedded in their constitutive models. Spacer grids have been found to have an important impact on the maximum allowable Critical Heat Flux within the fuel assembly of a nuclear reactor core. Therefore, incorporation of suitable spacer grids models can improve the critical heat flux prediction capability of best estimate codes. Realistic modeling of entrainment behavior of spacer grids requires understanding the different mechanisms that are involved. Since visual information pertaining to the entrainment behavior of spacer grids cannot possibly be obtained frommore » operating nuclear reactors, experiments have to be designed and conducted for this specific purpose. Most of the spacer grid experiments available in literature have been designed in view of obtaining quantitative data for the purpose of developing or modifying empirical formulations for heat transfer, critical heat flux or pressure drop. Very few experiments have been designed to provide fundamental information which can be used to understand spacer grid effects and phenomena involved in two phase flow. Air-water experiments were conducted to obtain visual information on the two-phase flow behavior both upstream and downstream of Boiling Water Reactor (BWR) spacer grids. The test section was designed and constructed using prototypic dimensions such as the channel cross-section, rod diameter and other spacer grid configurations of a typical BWR fuel assembly. The test section models the flow behavior in two adjacent sub channels in the BWR core. A portion of a prototypic BWR spacer grid accounting for two adjacent channels was used with industrial mild steel rods for the purpose of representing the channel internals. Symmetry was preserved in this practice, so that the channel walls could effectively be considered as the channel boundaries. Thin films were established on the rod surfaces by injecting water through a set of perforations at the bottom ends of the rods, ensuring that the flow upstream of the bottom-most spacer grid is predominantly annular. The flow conditions were regulated such that they represent typical BWR operating conditions. Photographs taken during experiments show that the film entrainment increases significantly at the spacer grids, since the points of contact between the rods and the grids result in a peeling off of large portions of the liquid film from the rod surfaces. Decreasing the water flow resulted in eventual drying out, beginning at positions immediately upstream of the spacer grids. (authors)« less
Spherical Joint Piston and Connecting Rod Developed
NASA Technical Reports Server (NTRS)
1996-01-01
Under an interagency agreement with the Department of Energy, the NASA Lewis Research Center manages a Heavy-Duty Diesel Engine Technology (HDET) research program. The overall program objectives are to reduce fuel consumption through increased engine efficiency, reduce engine exhaust emissions, and provide options for the use of alternative fuels. The program is administered with a balance of research contracts, university research grants, and focused in-house research. The Cummins Engine Company participates in the HDET program under a cost-sharing research contract. Cummins is researching and developing in-cylinder component technologies for heavy-duty diesel engines. An objective of the Cummins research is to develop technologies for a low-emissions, 55-percent thermal efficiency (LE-55) engine. The best current-production engines in this class achieve about 46-percent thermal efficiency. Federal emissions regulations are driving this technology. Regulations for heavy duty diesel engines were tightened in 1994, more demanding emissions regulations are scheduled for 1998, and another step is planned for 2002. The LE-55 engine emissions goal is set at half of the 1998 regulation level and is consistent with plans for 2002 emissions regulations. LE-55 engine design requirements to meet the efficiency target dictate a need to operate at higher peak cylinder pressures. A key technology being developed and evaluated under the Cummins Engine Company LE-55 engine concept is the spherical joint piston and connecting rod. Unlike conventional piston and connecting rod arrangements which are joined by a pin forming a hinged joint, the spherical joint piston and connecting rod use a ball-and-socket joint. The ball-and-socket arrangement enables the piston to have an axisymmetric design allowing rotation within the cylinder. The potential benefits of piston symmetry and rotation are reduced scuffing, improved piston ring sealing, improved lubrication, mechanical and thermal load symmetry, reduced bearing stresses, reduced running clearances, and reduced oil consumption. The spherical joint piston is a monolithic, squeeze-cast, fiber-reinforced aluminum piston. The connecting rod has a ball end that seats on a spherical saddle within the piston and is retained by a pair of aluminum bronze holder rings. The holder rings are secured by a threaded ring that mates with the piston. As part of the ongoing research and development activity, the Cummins Engine Company successfully completed a 100-hr test of the spherical joint piston and connecting rod at LE- 55 peak steady-state engine conditions. In addition, a 100-hr transient cycle test that varied engine conditions between LE-55 no-load and LE-55 full-load was successfully completed.
Hutter, E.
1959-09-01
A cluster of nuclear fuel rods aod a tubular casing through which a coolant flows in heat-change contact with the ruel rods are described. The casting is of trefoil section and carries the fuel rods, each of which has two fin engaging the serrated fins of the other two fuel rods, whereby the fuel rods are held in the casing and are interlocked against relative longitudinal movement.
Heat transfer unit and method for prefabricated vessel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tamburello, David A.; Kesterson, Matthew R; Hardy, Bruce J.
Vessel assemblies, heat transfer units for prefabricated vessels, and methods for heat transfer prefabricated vessel are provided. A heat transfer unit includes a central rod, and a plurality of peripheral rods surrounding the central rod and connected to the central rod. The plurality of peripheral rods are movable between a first collapsed position and a second bowed position, wherein in the second bowed position a midpoint of each of the plurality of peripheral rods is spaced from the central rod relative to in the first position. The heat transfer unit further includes a heat transfer element connected to one ofmore » the plurality of peripheral rods.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-29
...: Notice. SUMMARY: Pursuant to the National Environmental Policy Act of 1969, the General Services... of Entry. On July 21, 2011, the Acting Regional Administrator, Pacific Rim Region, approved the ROD...
ERIC Educational Resources Information Center
Beale, Ivan L.
2005-01-01
Computer assisted learning (CAL) can involve a computerised intelligent learning environment, defined as an environment capable of automatically, dynamically and continuously adapting to the learning context. One aspect of this adaptive capability involves automatic adjustment of instructional procedures in response to each learner's performance,…
Information Technology and Disabilities, 1994.
ERIC Educational Resources Information Center
McNulty, Tom, Ed.
1994-01-01
Four issues of this newsletter on information technology and disabilities (ITD) contain the following articles: "Building an Accessible CD-ROM Reference Station" (Rochelle Wyatt and Charles Hamilton); "Development of an Accessible User Interface for People Who Are Blind or Vision Impaired as Part of the Re-Computerisation of Royal Blind Society…
Constructing "Nerdiness": Characterisation in "The Big Bang Theory"
ERIC Educational Resources Information Center
Bednarek, Monika
2012-01-01
This paper analyses the linguistic construction of the televisual character Sheldon--the "main nerd" in the sitcom "The Big Bang Theory" (CBS, 2007-), approaching this construction of character through both computerised and "manual" linguistic analysis. More specifically, a computer analysis of dialogue (using concordances and keyword analysis) in…
Computerising the Salesforce: The Introduction of Technical Change in a Non-Union Workforce.
ERIC Educational Resources Information Center
Newell, Helen; Lloyd, Caroline
1998-01-01
Results of interviews with 13 pharmaceutical sales representatives, five sales managers, and six human-resource managers and 47 survey responses showed that introduction of information technology was seen as purely technical; human-resources departments played no role; and informal communication procedures enabled management to ignore individual…
Learner Affect in Computerised L2 Oral Grammar Practice with Corrective Feedback
ERIC Educational Resources Information Center
Bodnar, Stephen; Cucchiarini, Catia; Penning de Vries, Bart; Strik, Helmer; van Hout, Roeland
2017-01-01
Although corrective feedback (CF) has received much interest in the second language acquisition literature, relatively little research has investigated the relationship between CF and learner affect in concrete practice situations. The present study investigates learners' affective states and practice behaviour in a novel context: oral grammar…
Working Memory Interventions with Children: Classrooms or Computers?
ERIC Educational Resources Information Center
Colmar, Susan; Double, Kit
2017-01-01
The importance of working memory to classroom functioning and academic outcomes has led to the development of many interventions designed to enhance students' working memory. In this article we briefly review the evidence for the relative effectiveness of classroom and computerised working memory interventions in bringing about measurable and…
Physical and Psychosocial Environments Associated with Networked Classrooms
ERIC Educational Resources Information Center
Zandvliet, David B.; Fraser, Barry J.
2005-01-01
This article reports a study of the learning environments in computer networked classrooms. The study is unique in that it involved an evaluation of both the physical and psychosocial classroom environments in these computerised settings through the use of a combination of questionnaires and ergonomic evaluations. The study involved administering…
Students' Understanding of Molecular Structure Representations
ERIC Educational Resources Information Center
Ferk, Vesna; Vrtacnik, Margareta; Blejec, Andrej; Gril, Alenka
2003-01-01
The purpose of the investigation was to determine the meanings attached by students to the different kinds of molecular structure representations used in chemistry teaching. The students (n = 124) were from primary (aged 13-14 years) and secondary (aged 17-18 years) schools and a university (aged 21-25 years). A computerised "Chemical…
Datson, D J; Carter, N G
1988-10-01
The use of personal computers in accountancy and business generally has been stimulated by the availability of flexible software packages. We describe the implementation of a commercial software package designed for interfacing with laboratory instruments and highlight the ease with which it can be implemented, without the need for specialist computer programming staff.
Contactless heater floating zone refining and crystal growth
NASA Technical Reports Server (NTRS)
Lan, Chung-Wen (Inventor); Kou, Sindo (Inventor)
1993-01-01
Floating zone refining or crystal growth is carried out by providing rapid relative rotation of a feed rod and finish rod while providing heat to the junction between the two rods so that significant forced convection occurs in the melt zone between the two rods. The forced convection distributes heat in the melt zone to allow the rods to be melted through with a much shorter melt zone length than possible utilizing conventional floating zone processes. One of the rods can be rotated with respect to the other, or both rods can be counter-rotated, with typical relative rotational speeds of the rods ranging from 200 revolutions per minute (RPM) to 400 RPM or greater. Zone refining or crystal growth is carried out by traversing the melt zone through the feed rod.
Johnsen, Bjørn Helge; Hansen, Anita L; Murison, Robert; Eid, Jarle; Thayer, Julian F
2012-01-01
The aim of the paper was to study the relationship between heart rate variability (HRV) and cortisol release during cognitive challenging tasks. Forty-nine male naval cadets from the Royal Norwegian Naval Academy were administered computerised versions of attentional and working memory tests. The results from this study support the hypothesis of a negative correlation between HRV and cortisol secretion during cognitive tasks. Confirmation of the hypothesis with the low HRV group scoring higher on cortisol only during performance of cognitive tasks and recovery was also found. Furthermore, a replication of the previous findings of a negative association between cortisol levels and performance were supported when using uncorrected comparisons. None of the correlations survived Bonferonin corrections. The findings are discussed in relation to factors increasing HRV, thus improving tolerance to cognitive stress in onboard environments.
Television viewing and food consumption in Flemish adolescents in Belgium.
Vereecken, Carine Anna; Maes, Lea
2006-01-01
To examine associations of television viewing with overall food consumption A computerised 24-hour dietary recall and a questionnaire were completed by 1031 adolescents (+/- 12-14 years of age). Those who generally watched more television were more likely to consume frequently advertised items such as soft drinks and snacks. Not all frequently advertised food items (e.g. cereals) were associated with television viewing. An inverse association was found with fruit, water and milk. A negative association was found with brown bread; a positive association was found with white bread. The results indicate that high television viewing and a less nutrient dense food pattern are part of a lifestyle influenced by common underlying factors. Nutrition interventions aimed at improving adolescents' food habits should target high television-viewers. Our findings underline the importance of tackling socio-demographic differences.
Use of computers in dysmorphology.
Diliberti, J H
1988-01-01
As a consequence of the increasing power and decreasing cost of digital computers, dysmorphologists have begun to explore a wide variety of computerised applications in clinical genetics. Of considerable interest are developments in the areas of syndrome databases, expert systems, literature searches, image processing, and pattern recognition. Each of these areas is reviewed from the perspective of the underlying computer principles, existing applications, and the potential for future developments. Particular emphasis is placed on the analysis of the tasks performed by the dysmorphologist and the design of appropriate tools to facilitate these tasks. In this context the computer and associated software are considered paradigmatically as tools for the dysmorphologist and should be designed accordingly. Continuing improvements in the ability of computers to manipulate vast amounts of data rapidly makes the development of increasingly powerful tools for the dysmorphologist highly probable. PMID:3050092
Temporary Segmental Distraction in a Dog with Degenerative Lumbosacral Stenosis.
Willems, Nicole; Kersten, Roel F M R; van Gaalen, Steven M; Öner, F Cumhur; Strijkers, Gustav J; Veraa, Stefanie; Beukers, Martijn; Tryfonidou, Marianna A; Meij, Björn P
2018-06-02
Degenerative lumbosacral stenosis (DLSS) is characterized by intervertebral disc degeneration and causes lower back pain in dogs. Temporary distraction in rabbit models with induced intervertebral disc degeneration showed signs of intervertebral disc repair. In the present study, we assessed safety and efficacy of temporary segmental distraction in a dog with clinical signs of DLSS. Distraction of the lumbosacral junction by pedicle screw-rod fixation was applied in a 5-year-old Greyhound with DLSS and evaluated by radiography, magnetic resonance imaging, and force plate analysis before and after distraction. Safe distraction of the lumbosacral junction was demonstrated, with improvement of clinical signs after removal of the distraction device. Signal intensity of the intervertebral disc showed no changes over time. T2 value was highest directly after removal of the distraction device but decreased by 10% of the preoperative value at 9 months of follow-up. Disc height decreased (8%) immediately after removal of the distraction device, but recovered to the initial value. A decrease in the pelvic/thoracic propulsive force during pedicle screw-rod fixation and distraction was demonstrated, which slowly increased by 4% compared with the initial value. Temporary pedicle screw-rod fixation in combination with distraction in a dog with DLSS was safe, improved clinical signs and retained disc height at 9 months of follow-up. Schattauer GmbH Stuttgart.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ueno, Toshiyuki, E-mail: ueno@ec.t.kanazawa-u.ac.jp
2015-05-07
Vibration based power generation technology is utilized effectively in various fields. Author has invented novel vibrational power generation device using magnetostrictive material. The device is based on parallel beam structure consisting of a rod of iron-gallium alloy wound with coil and yoke accompanied with permanent magnet. When bending force is applied on the tip of the device, the magnetization inside the rod varies with induced stress due to the inverse magnetostrictive effect. In vibration, the time variation of the magnetization generates voltage on the wound coil. The magnetostrictive type is advantageous over conventional such using piezoelectric or moving magnet typesmore » in high efficiency and high robustness, and low electrical impedance. Here, author has established device configuration, simple, rigid, and high power output endurable for practical applications. In addition, the improved device is lower cost using less volume of Fe-Ga and permanent magnet compared to our conventional, and its assembly by soldering is easy and fast suitable for mass production. Average power of 3 mW/cm{sup 3} under resonant vibration of 212 Hz and 1.2 G was obtained in miniature prototype using Fe-Ga rod of 2 × 0.5× 7 mm{sup 3}. Furthermore, the damping effect was observed, which demonstrates high energy conversion of the generator.« less
Thorp, A.G. II
1962-08-01
An invention is described which relates to nuclear reactor control rod components and more particularly to a joint between cruciform control rod members and cruciform control rod follower members. In one embodiment this invention provides interfitting crossed arms at adjacent ends of a control rod and its follower in abutting relation. This holds the members against relative opposite longitudinal movement while a compression member keys the arms against relative opposite rotation around a common axis. Means are also provided for centering the control rod and its follower on a common axis and for selectively releasing the control rod from its follower for the insertion of a replacement of the control rod and reuse of the follower. (AEC)
Stimulus-evoked outer segment changes in rod photoreceptors
NASA Astrophysics Data System (ADS)
Zhao, Xiaohui; Thapa, Damber; Wang, Benquan; Lu, Yiming; Gai, Shaoyan; Yao, Xincheng
2016-06-01
Rod-dominated transient retinal phototropism (TRP) has been recently observed in freshly isolated mouse and frog retinas. Comparative confocal microscopy and optical coherence tomography revealed that the TRP was predominantly elicited from the rod outer segment (OS). However, the biophysical mechanism of rod OS dynamics is still unknown. Mouse and frog retinal slices, which displayed a cross-section of retinal photoreceptors and other functional layers, were used to test the effect of light stimulation on rod OSs. Time-lapse microscopy revealed stimulus-evoked conformational changes of rod OSs. In the center of the stimulated region, the length of the rod OS shrunk, while in the peripheral region, the rod OS swung toward the center region. Our experimental observation and theoretical analysis suggest that the TRP may reflect unbalanced rod disc-shape changes due to localized visible light stimulation.
Stimulus-evoked outer segment changes in rod photoreceptors
Zhao, Xiaohui; Thapa, Damber; Wang, Benquan; Lu, Yiming; Gai, Shaoyan; Yao, Xincheng
2016-01-01
Abstract. Rod-dominated transient retinal phototropism (TRP) has been recently observed in freshly isolated mouse and frog retinas. Comparative confocal microscopy and optical coherence tomography revealed that the TRP was predominantly elicited from the rod outer segment (OS). However, the biophysical mechanism of rod OS dynamics is still unknown. Mouse and frog retinal slices, which displayed a cross-section of retinal photoreceptors and other functional layers, were used to test the effect of light stimulation on rod OSs. Time-lapse microscopy revealed stimulus-evoked conformational changes of rod OSs. In the center of the stimulated region, the length of the rod OS shrunk, while in the peripheral region, the rod OS swung toward the center region. Our experimental observation and theoretical analysis suggest that the TRP may reflect unbalanced rod disc-shape changes due to localized visible light stimulation. PMID:27334933
Tapered laser rods as a means of minimizing the path length of trapped barrel mode rays
Beach, Raymond J.; Honea, Eric C.; Payne, Stephen A.; Mercer, Ian; Perry, Michael D.
2005-08-30
By tapering the diameter of a flanged barrel laser rod over its length, the maximum trapped path length of a barrel mode can be dramatically reduced, thereby reducing the ability of the trapped spontaneous emission to negatively impact laser performance through amplified spontaneous emission (ASE). Laser rods with polished barrels and flanged end caps have found increasing application in diode array end-pumped laser systems. The polished barrel of the rod serves to confine diode array pump light within the rod. In systems utilizing an end-pumping geometry and such polished barrel laser rods, the pump light that is introduced into one or both ends of the laser rod, is ducted down the length of the rod via the total internal reflections (TIRs) that occur when the light strikes the rod's barrel. A disadvantage of using polished barrel laser rods is that such rods are very susceptible to barrel mode paths that can trap spontaneous emission over long path lengths. This trapped spontaneous emission can then be amplified through stimulated emission resulting in a situation where the stored energy available to the desired lasing mode is effectively depleted, which then negatively impacts the laser's performance, a result that is effectively reduced by introducing a taper onto the laser rod.
Fuel rod assembly to manifold attachment
Donck, Harry A.; Veca, Anthony R.; Snyder, Jr., Harold J.
1980-01-01
A fuel element is formed with a plurality of fuel rod assemblies detachably connected to an overhead support with each of the fuel rod assemblies having a gas tight seal with the support to allow internal fission gaseous products to flow without leakage from the fuel rod assemblies into a vent manifold passageway system on the support. The upper ends of the fuel rod assemblies are located at vertically extending openings in the support and upper threaded members are threaded to the fuel rod assemblies to connect the latter to the support. The preferred threaded members are cap nuts having a dome wall encircling an upper threaded end on the fuel rod assembly and having an upper sealing surface for sealing contact with the support. Another and lower seal is achieved by abutting a sealing surface on each fuel rod assembly with the support. A deformable portion on the cap nut locks the latter against inadvertent turning off the fuel rod assembly. Orienting means on the fuel rod and support primarily locates the fuel rods azimuthally for reception of a deforming tool for the cap nut. A cross port in the fuel rod end plug discharges into a sealed annulus within the support, which serves as a circumferential chamber, connecting the manifold gas passageways in the support.
Athanasiou, Dimitra; Aguila, Monica; Opefi, Chikwado A.; South, Kieron; Bellingham, James; Bevilacqua, Dalila; Munro, Peter M.; Kanuga, Naheed; Mackenzie, Francesca E.; Dubis, Adam M.; Georgiadis, Anastasios; Graca, Anna B.; Pearson, Rachael A.; Ali, Robin R.; Sakami, Sanae; Palczewski, Krzysztof; Sherman, Michael Y.; Reeves, Philip J.
2017-01-01
Abstract Protein misfolding caused by inherited mutations leads to loss of protein function and potentially toxic ‘gain of function’, such as the dominant P23H rhodopsin mutation that causes retinitis pigmentosa (RP). Here, we tested whether the AMPK activator metformin could affect the P23H rhodopsin synthesis and folding. In cell models, metformin treatment improved P23H rhodopsin folding and traffic. In animal models of P23H RP, metformin treatment successfully enhanced P23H traffic to the rod outer segment, but this led to reduced photoreceptor function and increased photoreceptor cell death. The metformin-rescued P23H rhodopsin was still intrinsically unstable and led to increased structural instability of the rod outer segments. These data suggest that improving the traffic of misfolding rhodopsin mutants is unlikely to be a practical therapy, because of their intrinsic instability and long half-life in the outer segment, but also highlights the potential of altering translation through AMPK to improve protein function in other protein misfolding diseases. PMID:28065882
The Moment of Inertia of a Rectangular Rod
NASA Astrophysics Data System (ADS)
Takeuchi, Takao
2007-11-01
Recently an inexpensive setup to obtain the moment of inertia of a rotating system was proposed by Peter E. Banks. An equally simple and inexpensive experiment to obtain the moment of inertia of a uniform rod is proposed in this paper. A rectangular rod with a hole somewhere in the rod was used for this purpose. The moment of inertia of a rectangular rod around the hole location was attempted. The experimental setup is shown in Fig. 1. Various supporting rods, clamps, and rubber stoppers to hold the rectangular rod in place at point p are not shown.
Nuclear reactor control apparatus
Sridhar, Bettadapur N.
1983-11-01
Nuclear reactor core safety rod release apparatus comprises a control rod having a detent notch in the form of an annular peripheral recess at its upper end, a control rod support tube for raising and lowering the control rod under normal conditions, latches pivotally mounted on the control support tube with free ends thereof normally disposed in the recess in the control rod, and cam means for pivoting the latches out of the recess in the control rod when a scram condition occurs. One embodiment of the invention comprises an additional magnetically-operated latch for releasing the control rod under two different conditions, one involving seismic shock.
Nuclear thermionic converter. [tungsten-thorium oxide rods
NASA Technical Reports Server (NTRS)
Phillips, W. M.; Mondt, J. F. (Inventor)
1977-01-01
Efficient nuclear reactor thermionic converter units are described which can be constructed at low cost and assembled in a reactor which requires a minimum of fuel. Each converter unit utilizes an emitter rod with a fluted exterior, several fuel passages located in the bulges that are formed in the rod between the flutes, and a collector receiving passage formed through the center of the rod. An array of rods is closely packed in an interfitting arrangement, with the bulges of the rods received in the recesses formed between the bulges of other rods, thereby closely packing the nuclear fuel. The rods are constructed of a mixture of tungsten and thorium oxide to provide high power output, high efficiency, high strength, and good machinability.
Lightning discharge protection rod
NASA Technical Reports Server (NTRS)
Bryan, Charles F., Jr. (Inventor)
1987-01-01
A system for protecting an in-air vehicle from damage due to a lighning strike is disclosed. It is an extremely simple device consisting of a sacrificial graphite composite rod, approximately the diameter of a pencil with a length of about five inches. The sacrificial rod is constructed with the graphite fibers running axially within the rod in a manner that best provides a path of conduction axially from the trailing edge of an aircraft to the trailing end of the rod. The sacrificial rod is inserted into an attachment hole machined into trailing edges of aircraft flight surfaces, such as a vertical fin cap and attached with adhesive in a manner not prohibiting the conduction path between the rod and the aircraft. The trailing end of the rod may be tapered for aerodynamic and esthetic requirements. This rod is sacrificial but has the capability to sustain several lightning strikes and still provide protection.
Thermomechanical effects of spine surgery rods composed of different metals and alloys.
Noshchenko, Andriy; Patel, Vikas V; Baldini, Todd; Yun, Lu; Lindley, Emily M; Burger, Evalina L
2011-05-15
A basic science study monitoring changes in the curvature of hand contoured commercially pure titanium (CPTi), titanium-aluminum-vanadium alloy (Ti-6Al-4V), and stainless steel (SS) rods maintained at different temperature conditions. To quantify changes in rod-shape at temperatures representative of those used in clinical practice. The shape of implanted rods can be displaced due to thermo-mechanical properties of the materials. Warmer temperatures likely initiate this effect. A study of shape loss characteristics of various rod implants may help eliminate undesirable outcomes caused by shape displacement. Three different types of rods (CPTi, SS, and Ti-6Al-4V) were hand contoured and then maintained in one of following temperature conditions for 35 days: (1) room temperature (20 °C-25 °C) without autoclaving before contouring; (2) preliminary autoclaving (1, 5, 10, 20 cycles) at 135.0 °C ± 2 °C before contouring followed by body temperature (37.2 °C ± 2 °C). Each rod was 5 mm in diameter and 200 mm long. The rods were mounted over graph paper in fixed positions and photographed to measure displacement of the tip as a function of the curvature. RESULTS.: Statistically significant shape loss of the rods manufactured from all the tested materials was found. The hand contoured CPTi rods displayed considerably higher loss of curvature over time than Ti-6Al-4V and SS rods at all tested temperature conditions. Preliminary autoclaving at 135 °C before contouring tended to amplify this effect, in particular 1 cycle of autoclaving. If the number of preliminary autoclaving cycles was higher (5-10), a tendency of decrease of shape loss effect was observed in Ti-6Al-4V and CPTi rods. The shape of the hand contoured CPTi rods was the least stable of the rods across all applied temperature conditions. The SS and Ti-6Al-4V rods were more stable than CPTi rods. Autoclaving before handcontouring tended to increase rods' shape loss.
Cupric oxide inclusions in cuprous oxide crystals grown by the floating zone method
NASA Astrophysics Data System (ADS)
Frazer, Laszlo; Chang, Kelvin B.; Poeppelmeier, Kenneth R.; Ketterson, John B.
2015-06-01
Phase-pure cuprous oxide (Cu2O) crystals are difficult to grow since cupric oxide can form within the crystal as the crystal is cooled to ambient conditions. Vacancies are the solute which causes precipitation of macroscopic defects. Therefore, even when a mostly phase-pure single crystal is used as a feed rod, cupric oxide inclusions persist in the recrystallized solid. Control of the thermal profile during crystal growth, however, can improve phase-purity; a slow counter-rotation rate of the feed and seed rods results in fewer inclusions. Cupric oxide can be removed by annealing, which produces a factor of 540 ± 70 increase in phase-purity.
Resizing procedure for optimum design of structures under combined mechanical and thermal loading
NASA Technical Reports Server (NTRS)
Adelman, H. M.; Narayanaswami, R.
1976-01-01
An algorithm is reported for resizing structures subjected to combined thermal and mechanical loading. The algorithm is applicable to uniaxial stress elements (rods) and membrane biaxial stress members. Thermal Fully Stressed Design (TFSD) is based on the basic difference between mechanical and thermal stresses in their response to resizing. The TFSD technique is found to converge in fewer iterations than ordinary fully stressed design for problems where thermal stresses are comparable to the mechanical stresses. The improved convergence is demonstrated by example with a study of a simplified wing structure, built-up with rods and membranes and subjected to a combination of mechanical loads and a three dimensional temperature distribution.
Parametric study of rod-pinch diode using particle-in-cell simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, R.; Biswas, D., E-mail: raghav@barc.gov.in; Chandra, R.
2014-07-01
We perform Particle-In-Cell (PIC) simulation of KALI-30 GW pulsed power generator based rod-pinch diode. It is shown that ions emitted from the anode-plasma play a crucial role in diode dynamics. It is found that ions not only help in compensating the space charge due to electron beam, but also lead to enhancement of the local electric field at the side walls of the cathode leading to additional electron emission from the side wall. Electrons emanating from one side wall of the cathode tend to converge at the anode tip. This can be used to design an improved Flash X-ray source.more » (author)« less
Fine-tuning to minimize emittances of J-PARC RF-driven H{sup −} ion source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ueno, A., E-mail: akira.ueno@j-parc.jp; Ohkoshi, K.; Ikegami, K.
2016-02-15
The Japan Proton Accelerator Research Complex (J-PARC) cesiated RF-driven H{sup −} ion source has been successfully operated for about one year. By the world’s brightest level beam, the J-PARC design beam power of 1 MW was successfully demonstrated. In order to minimize the transverse emittances, the rod-filter-field (RFF) was optimized by changing the triple-gap-lengths of each of pairing five piece rod-filter-magnets. The larger emittance degradation seems to be caused by impurity-gases than the RFF. The smaller beam-hole-diameter of the extraction electrode caused the more than expected improvements on not only the emittances but also the peak beam intensity.
Cupric oxide inclusions in cuprous oxide crystals grown by the floating zone method
Frazer, Laszlo; Chang, Kelvin B; Poeppelmeier, Kenneth R; Ketterson, John B
2015-01-01
Phase-pure cuprous oxide (Cu2O) crystals are difficult to grow since cupric oxide can form within the crystal as the crystal is cooled to ambient conditions. Vacancies are the solute which causes precipitation of macroscopic defects. Therefore, even when a mostly phase-pure single crystal is used as a feed rod, cupric oxide inclusions persist in the recrystallized solid. Control of the thermal profile during crystal growth, however, can improve phase-purity; a slow counter-rotation rate of the feed and seed rods results in fewer inclusions. Cupric oxide can be removed by annealing, which produces a factor of 540 ± 70 increase in phase-purity. PMID:27877798
NASA Astrophysics Data System (ADS)
Ann, Ling Chuo; Mahmud, Shahrom; Bakhori, Siti Khadijah Mohd; Sirelkhatim, Amna; Mohamad, Dasmawati; Hasan, Habsah; Seeni, Azman; Rahman, Rosliza Abdul
2014-02-01
The effects of surface modification of zinc oxide (ZnO) powder and UVA illumination on the powder towards Escherichia coli and Staphylococcus aureus were investigated. FESEM-EDS results showed that oxygen annealing increased the O:Zn ratio on the surface of ZnO-rod and ZnO-plate samples. Surface conductances of ZnO-rod and ZnO-plate pellets were reduced from 1.05 nS to 0.15 nS and 1.34 nS to 0.23 nS, respectively. Meanwhile, UVA illumination on the surface of the ZnO-rod and ZnO-plate samples was found to improve surface conductance to 7.08 nS and 6.51 nS, respectively, due to the release of charge carrier. Photoluminescence results revealed that oxygen annealing halved the UV emission intensity and green emission intensity, presumably caused by oxygen absorption in the ZnO lattice. The antibacterial results showed that oxygen-treated ZnO exhibited slightly higher growth inhibition on E. coli and S. aureus compared with unannealed ZnO. UVA illumination on ZnO causes the greatest inhibition toward E. coli and S. aureus. Under the UVA excitation, the inhibition of E. coli increased by 18% (ZnO-rod) and 13% (ZnO-plate) while the inhibition of S. aureus increased by 22% (ZnO-rod) and 21% (ZnO-plate). Release of reactive oxygen species were proposed in antibacterial mechanisms, which were aided by surface modification and UVA photoactivation. The reactive oxygen species disrupted the DNA and protein synthesis of the bacterial cell, causing bacteriostatic effects toward E. coli and S. aureus.
Retinal photoreceptors and visual pigments in Boa constrictor imperator.
Sillman, A J; Johnson, J L; Loew, E R
2001-09-01
The photoreceptors of Boa constrictor, a boid snake of the subfamily Boinae, were examined with scanning electron microscopy and microspectrophotometry. The retina of B. constrictor is duplex but highly dominated by rods, cones comprising 11% of the photoreceptor population. The rather tightly packed rods have relatively long outer segments with proximal ends that are somewhat tapered. There are two morphologically distinct, single cones. The most common cone by far has a large inner segment and a relatively stout outer segment. The second cone, seen only infrequently, has a substantially smaller inner segment and a finer outer segment. The visual pigments of B. constrictor are virtually identical to those of the pythonine boid, Python regius. Three different visual pigments are present, all based on vitamin A(1.) The visual pigment of the rods has a wavelength of peak absorbance (lambda(max)) at 495 +/- 2 nm. The visual pigment of the more common, large cone has a lambda(max) at 549 +/- 1 nm. The small, rare cone contains a visual pigment with lambda(max) at 357 +/- 2 nm, providing the snake with sensitivity in the ultraviolet. We suggest that B. constrictor might employ UV sensitivity to locate conspecifics and/or to improve hunting efficiency. The data indicate that wavelength discrimination above 430 nm would not be possible without some input from the rods. Copyright 2001 Wiley-Liss, Inc.
Homma, Kohei; Okamoto, Satoshi; Mandai, Michiko; Gotoh, Norimoto; Rajasimha, Harsha K.; Chang, Yi-Sheng; Chen, Shan; Li, Wei; Cogliati, Tiziana; Swaroop, Anand; Takahashi, Masayo
2013-01-01
Replacement of dysfunctional or dying photoreceptors offers a promising approach for retinal neurodegenerative diseases, including age-related macular degeneration and retinitis pigmentosa. Several studies have demonstrated the integration and differentiation of developing rod photoreceptors when transplanted in wild type or degenerating retina; however, the physiology and function of the donor cells are not adequately defined. Here, we describe the physiological properties of developing rod photoreceptors that are tagged with GFP driven by the promoter of rod differentiation factor, Nrl. GFP-tagged developing rods show Ca2+ responses and rectifier outward currents that are smaller than those observed in fully developed photoreceptors, suggesting their immature developmental state. These immature rods also exhibit hyperpolarization-activated current (Ih) induced by the activation of hyperpolarization-activated cyclic nucleotide-gated (HCN) channels. When transplanted into the subretinal space of wild type or retinal degeneration mice, GFP-tagged developing rods can integrate into the photoreceptor outer nuclear layer in wild-type mouse retina, and exhibit Ca2+ responses and membrane current comparable to native rod photoreceptors. A proportion of grafted rods develop rhodopsin-positive outer segment-like structures within two weeks after transplantation into the retina of Crx-knockout mice, and produce rectifier outward current and Ih upon membrane depolarization and hyperpolarization. GFP-positive rods derived from induced pluripotent stem (iPS) cells also display similar membrane current Ih as native developing rod photoreceptors, express rod-specific phototransduction genes, and HCN-1 channels. We conclude that Nrl-promoter driven GFP-tagged donor photoreceptors exhibit physiological characteristics of rods and that iPS cell-derived rods in vitro may provide a renewable source for cell replacement therapy. PMID:23495178
NEUTRONIC REACTOR CONTROL ROD DRIVE APPARATUS
Oakes, L.C.; Walker, C.S.
1959-12-15
ABS>A suspension mechanism between a vertically movable nuclear reactor control rod and a rod extension, which also provides information for the operator or an automatic control signal, is described. A spring connects the rod extension to a drive shift. The extension of the spring indicates whether (1) the rod is at rest on the reactor, (2) the rod and extension are suspended, or (3) the extension alone is suspended, the spring controlling a 3-position electrical switch.
Kim, Chang Yeom; Son, Byeong Jae; Son, Jangyup; Hong, Jongill; Lee, Sang Yeul
2017-01-01
Background Silicone rod is a commonly used synthetic suspension material in frontalis suspension surgery to correct blepharoptosis. The most challenging problem and a decisive drawback of the use of silicone rod is a considerable rate of ptosis recurrence after surgery. We examined patients with recurred ptosis and assessed the physical and micromorphological properties of implanted silicone rods to determine the causative mechanisms of recurred ptosis after frontalis suspension using silicone rod. Methods This is a prospective observational case series of 22 pediatric patients with recurred ptosis after frontalis suspension using silicone rods for congenital ptosis. Implanted silicone rods were observed and removed during the operation for correction of recurred ptosis. The removed silicone rods were physically and micromorphologically evaluated to determine the cause of recurrence. Results Pretarsal fixation positions migrated upward, whereas suprabrow fixation positions migrated downward during ptosis recurrence. The breaking strength of implanted silicone rods was reduced by approximately 50% during 3 years. Cracks, debris, and loss of homogenous structure with disintegration were observed on scanning electron micrographs of implanted silicone rods in patients with recurred ptosis. Preoperative severe degree of ptosis also contributed to recurred ptosis. Conclusions Recurrence of ptosis after frontalis suspension using silicone rod was associated with physical changes of implanted silicone rods, including positional migration, weakened tensile strength, and micromorphological changes in combination with patients’ characteristics. PMID:28207846
Shiomi, Daisuke; Toyoda, Atsushi; Aizu, Tomoyuki; Ejima, Fumio; Fujiyama, Asao; Shini, Tadasu; Kohara, Yuji; Niki, Hironori
2013-03-01
RodZ interacts with MreB and both factors are required to maintain the rod shape of Escherichia coli. The assembly of MreB into filaments regulates the subcellular arrangement of a group of enzymes that synthesizes the peptidoglycan (PG) layer. However, it is still unknown how polymerization of MreB determines the rod shape of bacterial cells. Regulatory factor(s) are likely to be involved in controlling the function and dynamics of MreB. We isolated suppressor mutations to partially recover the rod shape in rodZ deletion mutants and found that some of the suppressor mutations occurred in mreB. All of the mreB mutations were in or in the vicinity of domain IA of MreB. Those mreB mutations changed the property of MreB filaments in vivo. In addition, suppressor mutations were found in the periplasmic regions in PBP2 and RodA, encoded by mrdA and mrdB genes. Similar to MreB and RodZ, PBP2 and RodA are pivotal to the cell wall elongation process. Thus, we found that mutations in domain IA of MreB and in the periplasmic domain of PBP2 and RodA can restore growth and rod shape to ΔrodZ cells, possibly by changing the requirements of MreB in the process. © 2013 Blackwell Publishing Ltd.
Shiomi, Daisuke; Toyoda, Atsushi; Aizu, Tomoyuki; Ejima, Fumio; Fujiyama, Asao; Shini, Tadasu; Kohara, Yuji; Niki, Hironori
2013-01-01
RodZ interacts with MreB and both factors are required to maintain the rod shape of Escherichia coli. The assembly of MreB into filaments regulates the subcellular arrangement of a group of enzymes that synthesizes the peptidoglycan (PG) layer. However, it is still unknown how polymerization of MreB determines the rod shape of bacterial cells. Regulatory factor(s) are likely to be involved in controlling the function and dynamics of MreB. We isolated suppressor mutations to partially recover the rod shape in rodZ deletion mutants and found that some of the suppressor mutations occurred in mreB. All of the mreB mutations were in or in the vicinity of domain IA of MreB. Those mreB mutations changed the property of MreB filaments in vivo. In addition, suppressor mutations were found in the periplasmic regions in PBP2 and RodA, encoded by mrdA and mrdB genes. Similar to MreB and RodZ, PBP2 and RodA are pivotal to the cell wall elongation process. Thus, we found that mutations in domain IA of MreB and in the periplasmic domain of PBP2 and RodA can restore growth and rod shape to ΔrodZ cells, possibly by changing the requirements of MreB in the process. PMID:23301723
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-31
... DEPARTMENT OF COMMERCE International Trade Administration [A-549-831] Steel Threaded Rod From... ``Department'') preliminarily determines that steel threaded rod from Thailand is being, or is likely to be... Investigation The merchandise covered by this investigation is steel threaded rod. Steel threaded rod is certain...
Measurement of Diffusion in Entangled Rod-Coil Triblock Copolymers
NASA Astrophysics Data System (ADS)
Olsen, B. D.; Wang, M.
2012-02-01
Although rod-coil block copolymers have attracted increasing attention for functional nanomaterials, their dynamics relevant to self-assembly and processing have not been widely investigated. Because the rod and coil blocks have different reptation behavior and persistence lengths, the mechanism by which block copolymers will diffuse is unclear. In order to understand the effect of the rigid block on reptation, tracer diffusion of a coil-rod-coil block copolymer through an entangled coil polymer matrix was experimentally measured. A monodisperse, high molecular weight coil-rod-coil triblock was synthesized using artificial protein engineering to prepare the helical rod and bioconjugaiton of poly(ethylene glycol) coils to produce the final triblock. Diffusion measurements were performed using Forced Rayleigh scattering (FRS), at varying ratios of the rod length to entanglement length, where genetic engineering is used to control the protein rod length and the polymer matrix concentration controls the entanglement length. As compared to PEO homopolymer tracers, the coil-rod-coil triblocks show markedly slower diffusion, suggesting that the mismatch between rod and coil reptation mechanisms results in hindered diffusion of these molecules in the entangled state.
Luhmann, S J; Sheridan, J J; Capelli, A M; Schoenecker, P L
1998-01-01
Twelve patients (seven boys, five girls) who had osteogenesis imperfecta were treated with an extensible-rod system in 21 femurs and 15 tibias. Indications for use of extensible rods were multiple fractures, long-bone deformity prohibiting bracing and ambulation, and significant remaining linear growth. The average patient age at the time of placement of the extensible rods was 6 + 8 years (range, 2 + 4-10 + 10). Six femurs were treated with overlapping Rush rods; Bailey-Dubow rods were used in the remaining femurs and in all tibias. The average length of follow-up was 5 + 9 years (range, 2 + 0-3 + 2). Preoperatively, four of the 12 patients had never walked; postoperatively, all were ambulators with varying levels of assistance. Fourteen complications occurred, 12 of which required operative revision of the extensible rods. The average time between primary extensible rodding and revision was 5 + 1 years. No complications have occurred to date related to the use of overlapping Rush rods. No growth disturbance resulted from the use of the extensible-rod systems.
The Possibilities and Limitations of Applying "Open Data" Principles in Schools
ERIC Educational Resources Information Center
Selwyn, Neil; Henderson, Michael; Chao, Shu-Hua
2017-01-01
Large quantities of data are now being generated, collated and processed within schools through computerised systems and other digital technologies. In response to growing concerns over the efficiency and equity of how these data are used, the concept of "open data" has emerged as a potential means of using digital technology to…
Development of a Computerised Method of Determining Aircraft Maintenance Intervals.
1985-09-01
Reliability. Vol.17. 1978. pp461-464. 23. , and Shunji Osaki. "Optimum Preventive Maintenance Policies for a 2-Unit Redundant System." IEEE...Transactions on Reliability. Vol.R-23. No.2. June 1974. pp86-91. 24. _ _, and Shunji Osaki. "A Summary of Optimum Preventive Maintenance Policies for a Two-Unit
USDA-ARS?s Scientific Manuscript database
Current methods for assessing children's dietary intake, such as interviewer-administered 24-h dietary recall (24-h DR), are time consuming and resource intensive. Self-administered instruments offer a low-cost diet assessment method for use with children. The present study assessed the validity of ...
Allocentric versus Egocentric Spatial Memory in Adults with Autism Spectrum Disorder
ERIC Educational Resources Information Center
Ring, Melanie; Gaigg, Sebastian B.; Altgassen, Mareike; Barr, Peter; Bowler, Dermot M.
2018-01-01
Individuals with autism spectrum disorder (ASD) present difficulties in forming relations among items and context. This capacity for relational binding is also involved in spatial navigation and research on this topic in ASD is scarce and inconclusive. Using a computerised version of the Morris Water Maze task, ASD participants showed particular…
Spelling: Computerised Feedback for Self-Correction
ERIC Educational Resources Information Center
Lawley, Jim
2016-01-01
Research has shown that any assumption that L2 learners of English do well to rely on the feedback provided by generic spell checkers (for example, the MS Word spell checker) is misplaced. Efforts to develop spell checkers specifically for L2 learners have focused on training software to offer more appropriate suggestion lists for replacing…
Fruit and vegetables are similarly categorised by 8-13-year-old children
USDA-ARS?s Scientific Manuscript database
This exploratory study assessed how 8- to 13-year-old children categorized and labelled fruit and vegetables (FaV), and how these were influenced by child characteristics, to specify second-level categories in a hierarchical food search system for a computerised 24-h dietary recall (hdr). Two sets o...
Evidence of Virtual Patients as a Facilitative Learning Tool on an Anesthesia Course
ERIC Educational Resources Information Center
Leung, Joseph Y. C.; Critchley, Lester A. H.; Yung, Alex L. K.; Kumta, Shekhar M.
2015-01-01
Virtual patients are computerised representations of realistic clinical cases. They were developed to teach clinical reasoning skills through delivery of multiple standardized patient cases. The anesthesia course at The Chinese University of Hong Kong developed two novel types of virtual patients, formative assessment cases studies and storyline,…
Quest for a Computerised Semantics.
ERIC Educational Resources Information Center
Leslie, Adrian R.
The objective of this thesis was to colligate the various strands of research in the literature of computational linguistics that have to do with the computational treatment of semantic content so as to encode it into a computerized dictionary. In chapter 1 the course of mechanical translation (1947-1960) and quantitative linguistics is traced to…
Identifying Reading Problems with Computer-Adaptive Assessments
ERIC Educational Resources Information Center
Merrell, C.; Tymms, P.
2007-01-01
This paper describes the development of an adaptive assessment called Interactive Computerised Assessment System (InCAS) that is aimed at children of a wide age and ability range to identify specific reading problems. Rasch measurement has been used to create the equal interval scales that form each part of the assessment. The rationale for the…
ERIC Educational Resources Information Center
Krzok, Franziska; Rieger, Verena; Niemann, Katharina; Nobis-Bosch, Ruth; Radermacher, Irmgard; Huber, Walter; Willmes, Klaus; Abel, Stefanie
2018-01-01
Background: SAPS--'Sprachsystematisches Aphasiescreening'--is a novel language-systematic aphasia screening developed for the German language, which already had been positively evaluated. It offers a fast assessment of modality-specific psycholinguistic components at different levels of complexity and the derivation of impairment-based treatment…
Developing a Computerised Multiple Elements Test for Organisational Difficulties
ERIC Educational Resources Information Center
Hynes, Sinead M.; Fish, Jessica; Evans, Jonathan J.; Manly, Tom
2015-01-01
Executive function is best measured in loosely structured, multi-component tasks that reflect real-life demands. These tasks require participants to develop a strategy, keep a plan in mind and monitor time. Errors include ignoring stated goals ("goal neglect"), over-allocation of time to one task and violating rules. Teasing apart such…
Computer-Based Working Memory Training in Children with Mild Intellectual Disability
ERIC Educational Resources Information Center
Delavarian, Mona; Bokharaeian, Behrouz; Towhidkhah, Farzad; Gharibzadeh, Shahriar
2015-01-01
We designed a working memory (WM) training programme in game framework for mild intellectually disabled students. Twenty-four students participated as test and control groups. The auditory and visual-spatial WM were assessed by primary test, which included computerised Wechsler numerical forward and backward sub-tests and secondary tests, which…
Inclusion in Physical Education: A Review of Literature
ERIC Educational Resources Information Center
Qi, Jing; Ha, Amy S.
2012-01-01
The purpose of this review was to analyse empirical studies on inclusion in physical education (PE) over the past 20 years and then propose recommendations for future research. A systematic process was used to search the literature for this review. First, a total of 75 research-based articles from computerised education databases were included in…
Slice-thickness evaluation in CT and MRI: an alternative computerised procedure.
Acri, G; Tripepi, M G; Causa, F; Testagrossa, B; Novario, R; Vermiglio, G
2012-04-01
The efficient use of computed tomography (CT) and magnetic resonance imaging (MRI) equipment necessitates establishing adequate quality-control (QC) procedures. In particular, the accuracy of slice thickness (ST) requires scan exploration of phantoms containing test objects (plane, cone or spiral). To simplify such procedures, a novel phantom and a computerised LabView-based procedure have been devised, enabling determination of full width at half maximum (FWHM) in real time. The phantom consists of a polymethyl methacrylate (PMMA) box, diagonally crossed by a PMMA septum dividing the box into two sections. The phantom images were acquired and processed using the LabView-based procedure. The LabView (LV) results were compared with those obtained by processing the same phantom images with commercial software, and the Fisher exact test (F test) was conducted on the resulting data sets to validate the proposed methodology. In all cases, there was no statistically significant variation between the two different procedures and the LV procedure, which can therefore be proposed as a valuable alternative to other commonly used procedures and be reliably used on any CT and MRI scanner.
Changes in wall teichoic acid during the rod-sphere transition of Bacillus subtilis 168.
Pollack, J H; Neuhaus, F C
1994-01-01
Wall teichoic acid (WTA) is essential for the growth of Bacillus subtilis 168. To clarify the function of this polymer, the WTAs of strains 168, 104 rodB1, and 113 tagF1 (rodC1) grown at 32 and 42 degrees C were characterized. At the restrictive temperature, the rodB1 and tagF1 (rodC1) mutants undergo a rod-to-sphere transition that is correlated with changes in the WTA content of the cell wall. The amount of WTA decreased 33% in strain 104 rodB1 and 84% in strain 113 tagF1 (rodC1) when they were grown at the restrictive temperature. The extent of alpha-D-glucosylation (0.84) was not affected by growth at the higher temperature in these strains. The degree of D-alanylation decreased from 0.22 to 0.10 in the rodB1 mutant but remained constant (0.12) in the tagF1 (rodC1) mutant at both temperatures. Under these conditions, the degree of D-alanylation in the parent strain decreased from 0.27 to 0.21. The chain lengths of WTA in strains 168 and 104 rodB1 grown at both temperatures were approximately 53 residues, with a range of 45 to 60. In contrast, although the chain length of WTA from the tagF1 (rodC1) mutant at 32 degrees C was similar to that of strains 168 and 104 rodB1, it was approximately eight residues at the restrictive temperature. The results suggested that the rodB1 mutant is partially deficient in completed poly(glycerophosphate) chains. The precise biochemical defect in this mutant remains to be determined. The results for strain 113 tagF1(rodC1) are consistent with the temperature-sensitive defect in the CDP-glycerol:poly(glycerophosphate) glycerophosphotransferase (H. M. Pooley, F.-X. Abellan, and D. Karamata, J. Bacteriol. 174:646-649, 1992). Images PMID:7961496
Outcomes of support rod usage in loop stoma formation.
Whiteley, Ian; Russell, Michael; Nassar, Natasha; Gladman, Marc A
2016-06-01
Traditionally, support rods have been used when creating loop stomas in the hope of preventing retraction. However, their effectiveness has not been clearly established. This study aimed to investigate the rate of stoma rod usage and its impact on stoma retraction and complication rates. A prospective cohort of 515 consecutive patients who underwent loop ileostomy/colostomy formation at a tertiary referral colorectal unit in Sydney, Australia were studied. Mortality and unplanned return to theatre rates were calculated. The primary outcome measure of interest was stoma retraction, occurring within 30 days of surgery. Secondary outcome measures included early stoma complications. The 10-year temporal trends for rod usage, stoma retraction, and complications were examined. Mortality occurred in 23 patients (4.1 %) and unplanned return to theatre in 4 patients (0.8 %). Stoma retraction occurred in four patients (0.78 %), all without rods. However, the rate of retraction was similar, irrespective of whether rods were used (P = 0.12). There was a significant decline in the use of rods during the study period (P < 0.001) but this was not associated with an increase in stoma retraction rates. Early complications occurred in 94/432 patients (21.8 %) and were more likely to occur in patients with rods (64/223 versus 30/209 without rods, P < 0.001). Stoma retraction is a rare complication and its incidence is not significantly affected by the use of support rods. Further, complications are common post-operatively, and the rate appears higher when rods are used. The routine use of rods warrants judicious application. WHAT DOES THIS PAPER ADD TO THE LITERATURE?: It remains unclear whether support rods prevent stoma retraction. This study, the largest to date, confirms that stoma retraction is a rare complication and is not significantly affected by the use of rods. Consequently, routine rod usage cannot be recommended, particularly as it is associated with increased stoma complications.
Method and means of packaging nuclear fuel rods for handling
Adam, Milton F.
1979-01-01
Nuclear fuel rods, especially spent nuclear fuel rods that may show physical distortion, are encased within a metallic enclosing structure by forming a tube about the fuel rod. The tube has previously been rolled to form an overlapping tubular structure and then unrolled and coiled about an axis perpendicular to the tube. The fuel rod is inserted into the tube as the rolled tube is removed from a coiled strip and allowed to reassume its tubular shape about the fuel rod. Rollers support the coiled strip in an open position as the coiled strip is uncoiled and allowed to roll about the fuel rod.
Light responses in rods of vitamin A-deprived Xenopus.
Solessio, Eduardo; Umino, Yumiko; Cameron, David A; Loew, Ellis; Engbretson, Gustav A; Knox, Barry E; Barlow, Robert B
2009-09-01
Accumulation of free opsin by mutations in rhodopsin or insufficiencies in the visual cycle can lead to retinal degeneration. Free opsin activates phototransduction; however, the link between constitutive activation and retinal degeneration is unclear. In this study, the photoresponses of Xenopus rods rendered constitutively active by vitamin A deprivation were examined. Unlike their mammalian counterparts, Xenopus rods do not degenerate. Contrasting phototransduction in vitamin A-deprived Xenopus rods with phototransduction in constitutively active mammalian rods may provide new understanding of the mechanisms that lead to retinal degeneration. The photocurrents of Xenopus tadpole rods were measured with suction electrode recordings, and guanylate cyclase activity was measured with the IBMX (3-isobutyl-1-methylxanthine) jump technique. The amount of rhodopsin in rods was determined by microspectrophotometry. The vitamin A-deprived rod outer segments were 60% to 70% the length and diameter of the rods in age-matched animals. Approximately 90% of its opsin content was in the free or unbound form. Analogous to bleaching adaptation, the photoresponses were desensitized (10- to 20-fold) and faster. Unlike bleaching adaptation, the vitamin A-deprived rods maintained near normal saturating (dark) current densities by developing abnormally high rates of cGMP synthesis. Their rate of cGMP synthesis in the dark (15 seconds(-1)) was twofold greater than the maximum levels attainable by control rods ( approximately 7 seconds(-1)). Preserving circulating current density and response range appears to be an important goal for rod homeostasis. However, the compensatory changes associated with vitamin A deprivation in Xenopus rods come at the high metabolic cost of a 15-fold increase in basal ATP consumption.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jy-An John; Wang, Hong; Bevard, Bruce Balkcom
Transportation packages for spent nuclear fuel (SNF) must meet safety requirements under normal and accident conditions as specified by federal regulations. During transportation, SNF experiences unique conditions and challenges to cladding integrity due to the vibrational and impact loading during road or rail shipment. Oak Ridge National Laboratory (ORNL) has been developing testing capabilities that can be used to improve the understanding of the impacts on SNF integrity due to vibration loading, especially for high burn-up SNF in normal transportation operation conditions. This information can be used to meet the nuclear industry and U.S. Nuclear Regulatory Commission needs in themore » area of safety and security of spent nuclear fuel storage and transport operations. The ORNL developed test system can perform reversible-bending fatigue testing to evaluate both the static and dynamic mechanical response of SNF rods under simulated loads. The testing apparatus is also designed to meet the challenges of hot-cell operation, including remote installation and detachment of the SNF test specimen, in-situ test specimen deformation measurement, and implementation of a driving system suitable for use in a hot cell. The system contains a U-frame set-up equipped with uniquely designed grip rigs, to protect SNF rod and to ensure valid test results, and use of 3 specially designed LVDTs to obtain the in-situ curvature measurement. A variety of surrogate test rods have been used to develop and calibrate the test system as well as in performing a series of systematic cyclic fatigue tests. The surrogate rods include stainless steel (SS) cladding, SS cladding with cast epoxy, and SS cladding with alumina pellets inserts simulating fuel pellets. Testing to date has shown that the interface bonding between the SS cladding and the alumina pellets has a significant impact on the bending response of the test rods as well as their fatigue strength. The failure behaviors observed from tested surrogate rods provides a fundamental understanding of the underlying failure mechanisms of the SNF surrogate rod under vibration which has not been achieved previously. The newly developed device is scheduled to be installed in the hot-cell in summer 2013 to test high burnup SNF.« less
Variable flow control for a nuclear reactor control rod
Carleton, Richard D.; Bhattacharyya, Ajay
1978-01-01
A variable flow control for a control rod assembly of a nuclear reactor that depends on turbulent friction though an annulus. The annulus is formed by a piston attached to the control rod drive shaft and a housing or sleeve fitted to the enclosure housing the control rod. As the nuclear fuel is burned up and the need exists for increased reactivity, the control rods are withdrawn, which increases the length of the annulus and decreases the rate of coolant flow through the control rod assembly.
Lightning protection using energized Franklin rods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdel-Salam, M.; Al-Abdul-Latif, U.
1995-12-31
In this paper, the onset criterion of the upward streamers from an energized Franklin rod is formulated as a function of the geometry of the rod and the height and current of the downward leader. The electric field in the vicinity of the lightning rod is calculated using the charge simulation technique. The dependency of the radius of protection on the amplitude of the pulse voltage applied to Franklin rod, the downward leader current and the tip radius and height of the rod is investigated.
Optimization of a rod pinch diode radiography source at 2.3 MV
NASA Astrophysics Data System (ADS)
Menge, P. R.; Johnson, D. L.; Maenchen, J. E.; Rovang, D. C.; Oliver, B. V.; Rose, D. V.; Welch, D. R.
2003-08-01
Rod pinch diodes have shown considerable capability as high-brightness flash x-ray sources for penetrating dynamic radiography. The rod pinch diode uses a small diameter (0.4-2 mm) anode rod extended through a cathode aperture. When properly configured, the electron beam born off of the aperture edge can self-insulate and pinch onto the tip of the rod creating an intense, small x-ray source. Sandia's SABRE accelerator (2.3 MV, 40 Ω, 70 ns) has been utilized to optimize the source experimentally by maximizing the figure of merit (dose/spot diameter2) and minimizing the diode impedance droop. Many diode parameters have been examined including rod diameter, rod length, rod material, cathode aperture diameter, cathode thickness, power flow gap, vacuum quality, and severity of rod-cathode misalignment. The configuration producing the greatest figure of merit uses a 0.5 mm diameter gold rod, a 6 mm rod extension beyond the cathode aperture (diameter=8 mm), and a 10 cm power flow gap to produce up to 3.5 rad (filtered dose) at 1 m from a 0.85 mm x-ray on-axis spot (1.02 mm at 3° off axis). The resultant survey of parameter space has elucidated several physics issues that are discussed.
Ultrasonic Structural Health Monitoring to Assess the Integrity of Spinal Growing Rods In Vitro.
Oetgen, Matthew E; Goodley, Addison; Yoo, Byungseok; Pines, Darryll J; Hsieh, Adam H
2016-01-01
Rod fracture is a common complication of growing rods and can result in loss of correction, patient discomfort, and unplanned revision surgery. The ability to quantitate rod integrity at each lengthening would be advantageous to avoid this complication. We investigate the feasibility of applying structural health monitoring to evaluate the integrity of growing rods in vitro. Single-rod titanium 4.5-mm growing rod constructs (n = 9), one screw proximally and one distally connected by in-line connectors, were assembled with pedicle screws fixed in polyethylene blocks. Proximal and distal ends were loaded and constructs subjected to cyclic axial compression (0-100 N at 1 Hz), with incrementally increasing maximum compressive loads of 10 N every 9k cycles until failure. Four piezoceramic transducers (PZTs) were mounted along the length the constructs to interrogate the integrity of the rods with an ultrasonic, guided lamb wave approach. Every 9k cycles, an 80 V excitatory voltage was applied to a PZT to generate high-frequency vibrations, which, after propagating through the construct, was detected by the remaining PZTs. Amplitude differences between pre- and postload waveform signals were calculated until rod failure. Average construct lifetime was 88,991 ± 13,398 cycles. All constructs failed due to rod fracture within 21 mm (mean = 15 ± 4.5 mm) of a screw or connector. Amplitude differences between pre- and postload increased in a stepwise fashion as constructs were cycled. Compared to baseline, we found a 1.8 ± 0.6-fold increase in amplitude 18k cycles before failure, a 2.2 ± 1.0-fold increase in amplitude 9k cycles before failure, and a 2.75 ± 1.5-fold increase in amplitude immediately before rod fracture. We describe a potential method for assessing the structural integrity of growing rods using ultrasonic structural health monitoring. These preliminary data demonstrate the ability of periodic rod assessment to detect structural changes in cycled growing rods, which appear to correspond to subclinical rod fatigue before rod fracture. Copyright © 2016 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.
Supplementation with macular carotenoids improves visual performance of transgenic mice.
Li, Binxing; Rognon, Gregory T; Mattinson, Ty; Vachali, Preejith P; Gorusupudi, Aruna; Chang, Fu-Yen; Ranganathan, Arunkumar; Nelson, Kelly; George, Evan W; Frederick, Jeanne M; Bernstein, Paul S
2018-07-01
Carotenoid supplementation can improve human visual performance, but there is still no validated rodent model to test their effects on visual function in laboratory animals. We recently showed that mice deficient in β-carotene oxygenase 2 (BCO2) and/or β-carotene oxygenase 1 (BCO1) enzymes can accumulate carotenoids in their retinas, allowing us to investigate the effects of carotenoids on the visual performance of mice. Using OptoMotry, a device to measure visual function in rodents, we examined the effect of zeaxanthin, lutein, and β-carotene on visual performance of various BCO knockout mice. We then transgenically expressed the human zeaxanthin-binding protein GSTP1 (hGSTP1) in the rods of bco2 -/- mice to examine if delivering more zeaxanthin to retina will improve their visual function further. The visual performance of bco2 -/- mice fed with zeaxanthin or lutein was significantly improved relative to control mice fed with placebo beadlets. β-Carotene had no significant effect in bco2 -/- mice but modestly improved cone visual function of bco1 -/- mice. Expression of hGSTP1 in the rods of bco2 -/- mice resulted in a 40% increase of retinal zeaxanthin and further improvement of visual performance. This work demonstrates that these "macular pigment mice" may serve as animal models to study carotenoid function in the retina. Copyright © 2018 Elsevier Inc. All rights reserved.
Axially shaped channel and integral flow trippers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crowther, R.L.; Johansson, E.B.; Matzner, B.
1988-06-07
A fuel assembly is described comprising fuel rods positioned in spaced array by upper and lower tie-plates, an open ended flow channel surrounding the array for conducting coolant upward between a lower support plate having coolant communicated thereto to an upper support grid having a steam/water outlet communicated thereto. The flow channel surrounds the array for conducting coolant about the fuel rods. The open ended channel has a polygon shaped cross section with the channel constituting a closed conduit with flat side sections connected at corners to form the enclosed conduit; means separate from the channel for connecting the uppermore » and lower tie-plates together and maintaining the fuel rods in spaced array independent of the flow channel. The improvement in the flow channel comprises tapered side walls. The tapered side walls extend from an average thick cross section adjacent the lower support plate to an average thin cross section adjacent the upper core grid whereby the channel is reduced in thickness adjacent the upper core grid to correspond with the reduced pressure adjacent the upper core grid.« less
Axially shaped channel and integral flow trippers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crowther, R.L. Jr.; Johansson, E.B.; Matzner, B.
1992-02-11
This patent describes a fuel assembly. It comprises: fuel rods positioned in spaced array by upper and lower tie-plates, and open ended flow channel surrounding the array for conducting coolant upward between a lower support plate having coolant communicated thereto to an upper support grid having a steam/water outlet communicated thereto. The flow channel surrounding the array for conducting coolant about the fuel rods; the open ended channel having a polygon shaped cross section with the channel constituting a closed conduit with flat side sections connected at corners to form the enclosed conduit; means separate from the channel for connectingmore » the upper and lower tie-plates together and maintaining the fuel rods in spaced array independent of the flow channel, the improvement in the flow channel comprising tapered side walls, the tapered side walls extending from an average thick cross section adjacent the lower support plate to an average thin cross section adjacent the upper core grid whereby the channel is reduced in thickness adjacent the upper core grid to correspond with the reduced pressure adjacent the upper core grid.« less
NASA Astrophysics Data System (ADS)
Gioffré, M.; Cavalagli, N.; Pepi, C.; Trequattrini, M.
2017-01-01
Non-contact measurements can be effectively used in civil engineering to assess the variation of structural performance with time. In the last decades this approach has received considerable interests from researchers working in the field of structural health monitoring (SHM). Indeed, non-contact measurements are very attractive because it is possible to perform non intrusive and non destructive investigations even being at a significant distance from the targets. Within this context, contactless measurements of the tie-rod vibrations in the Santa Maria della Consolazione Temple in Todi (Italy) are presented in this paper. In particular, laser vibrometer and radar interferometer measurements are used to estimate natural frequencies and mode shapes. This information is crucial to obtain the tensile axial force in the tie-rods, which can be used as an indicator of structural integrity or possible failure. Furthermore, a novel approach is proposed where drones (Unmanned Aerial Vehicles) can be successfully used to improve the effectiveness and the accuracy of the experimental activities.
Shot-by-shot Spectrum Model for Rod-pinch, Pulsed Radiography Machines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, William Monford
A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t), and current, I(t). The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thusmore » allowing for rapid optimization of the model across many shots. “Goodness of fit” is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays (“MCNPX”) model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. In conclusion, improvements to the model, specifically for application to other geometries, are discussed.« less
Shot-by-shot Spectrum Model for Rod-pinch, Pulsed Radiography Machines
Wood, William Monford
2018-02-07
A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t), and current, I(t). The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thusmore » allowing for rapid optimization of the model across many shots. “Goodness of fit” is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays (“MCNPX”) model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. In conclusion, improvements to the model, specifically for application to other geometries, are discussed.« less
NASA Astrophysics Data System (ADS)
Yan, Guanghua; Han, Lizhan; Li, Chuanwei; Luo, Xiaomeng; Gu, Jianfeng
2017-01-01
Retained austenite(RA) usually presents in the quenched Nuclear Pressure-Vessel SA508 Gr.3 steel. In the present work, the characteristic of RA decomposition and its effect on the impact toughness were investigated by microstructure observation, dilatometric experiments and Charpy impact tests. The results show that the RA transformed into martensite and bainite during tempering at 230 °C and 400 °C respectively, while mixture of long rod carbides and ferrite formed at 650 °C. The long rod carbides formed from RA decomposition decrease the critical cleavage stress for initiation of micro-cracks, and deteriorate the impact toughness of the steel. Pre-tempering at a low temperature such as 230 °C or 400 °C leading to the decomposition of RA into martensite or baintie can eliminate the deterioration of the toughness caused by direct decomposition into long rod carbides. The absorbed energy indicate that pre-tempering at 400 °C can drive dramatically improvement in the toughness of the steel.
Shot-by-shot spectrum model for rod-pinch, pulsed radiography machines
NASA Astrophysics Data System (ADS)
Wood, Wm M.
2018-02-01
A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t), and current, I(t). The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thus allowing for rapid optimization of the model across many shots. "Goodness of fit" is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays ("MCNPX") model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. Improvements to the model, specifically for application to other geometries, are discussed.
75 FR 21658 - Carbon and Certain Alloy Steel Wire Rod From Trinidad and Tobago
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-26
... Certain Alloy Steel Wire Rod From Trinidad and Tobago AGENCY: United States International Trade Commission... Investigation No. 731-TA-961 concerning carbon and certain alloy steel wire rod (``wire rod'') from Trinidad and... of imports of wire rod from Trinidad and Tobago that were sold in the United States at less than fair...
78 FR 2658 - Carbon and Certain Alloy Steel Wire Rod From Mexico: Rescission of Antidumping Duty...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-14
... Steel Wire Rod From Mexico: Rescission of Antidumping Duty Administrative Review; 2011-2012 AGENCY... order on carbon and certain alloy steel wire rod (``wire rod'') from Mexico for the period October 1... order on wire rod from Mexico for the period of review, October 1, 2011, through September 30, 2012.\\1...
NASA Astrophysics Data System (ADS)
Sotelo, A.; Madre, M. A.; Diez, J. C.; Rasekh, Sh; Angurel, L. A.; Martínez, E.
2009-03-01
Textured rods of Bi-2212 based materials with nominal compositions Bi2Sr2CaCu2O8+δ, Bi2Sr2CaCu2O8+δ+1 wt% Ag, Bi1.6Pb0.4Sr2CaCu2O8+δ, and Bi1.6Pb0.4Sr2CaCu2O8+δ+3 wt% Ag were fabricated using a laser floating zone (LFZ) melting method. The electrical, magnetic, and mechanical properties of the resulting rods after annealing were characterized. Pb doping results in the decrease of the transport critical current density, Jc,t (from 4.4 × 107 to 6 × 106 A m-2 at 65 K and self-field) as well as in the worsening of the mechanical properties, by about 35% compared to the undoped samples. In contrast, Ag doping results in the improvement of both the critical current density and mechanical strength. In this regard we have observed an increase of Jc,t (65 K) from 4.4 × 107 for Bi-2212 to 7.2 × 107 A m-2 for Bi-2212/Ag and from 6 × 106 for Bi(Pb)-2212 to 8 × 106 A m-2 for Bi(Pb)-2212/Ag. These described effects are related to the microstructural observations, since Pb doping dramatically reduces the texture while Ag doping improves it. Moreover, for samples with Ag addition, an intergrowth of Bi-2223 inside the Bi-2212 grains is observed, which would explain the improved superconducting properties of these samples.
Wittwer, Joanne E; Webster, Kate E; Hill, Keith
2013-01-01
To investigate whether synchronising over-ground walking to rhythmic auditory cues improves temporal and spatial gait measures in adults with neurological clinical conditions other than Parkinson's disease. A search was performed in June 2011 using the computerised databases AGELINE, AMED, AMI, CINAHL, Current Contents, EMBASE, MEDLINE, PsycINFO and PUBMED, and extended using hand-searching of relevant journals and article reference lists. Methodological quality was independently assessed by two reviewers. A best evidence synthesis was applied to rate levels of evidence. Fourteen studies, four of which were randomized controlled trials (RCTs), met the inclusion criteria. Patient groups included those with stroke (six studies); Huntington's disease and spinal cord injury (two studies each); traumatic brain injury, dementia, multiple sclerosis and normal pressure hydrocephalus (one study each). The best evidence synthesis found moderate evidence of improved velocity and stride length of people with stroke following gait training with rhythmic music. Insufficient evidence was found for other included neurological disorders due to low study numbers and poor methodological quality of some studies. Synchronising walking to rhythmic auditory cues can result in short-term improvement in gait measures of people with stroke. Further high quality studies are needed before recommendations for clinical practice can be made.
Dymowski, Alicia Rhian; Ponsford, Jennie Louise; Willmott, Catherine
2016-10-01
Attentional deficits are common following traumatic brain injury (TBI) and interfere with daily functioning. This study employed a single-case design to examine the effects of individualised strategy training on attention beyond the effects of computerised training using Attention Process Training 3 (APT-3), and to examine the participants' subjective experience of these approaches. An ABCA (baseline, APT-3, strategy training, follow-up) design was repeated across three participants with severe TBI. Outcomes were measured on alternate versions of the oral Symbol Digit Modalities Test (SDMT) and cancellation tasks; generalisation with the Test of Everyday Attention (TEA) and self and significant other (SO) ratings on the Rating Scale of Attentional Behaviour (RSAB); and participant experiences with semi-structured interviews. Planned Tau-U analyses revealed improvements in speed of processing on the SDMT and the automatic condition of the cancellation task after APT-3 and at follow-up, but with most improvement after strategy training. Limited generalisation was evident on TEA subtests and self-RSAB ratings. SO-RSAB ratings were mixed after APT-3, but demonstrated improvement after strategy training. Variability in attentional deficits and everyday attentional requirements between patients required individualised goals and approaches to rehabilitation. This study highlights the need for individualised rehabilitation of attention to improve everyday functioning after TBI.
Staff, Michael; Roberts, Christopher; March, Lyn
2016-10-01
To describe the completeness of routinely collected primary care data that could be used by computer models to predict clinical outcomes among patients with Type 2 Diabetes (T2D). Data on blood pressure, weight, total cholesterol, HDL-cholesterol and glycated haemoglobin levels for regular patients were electronically extracted from the medical record software of 12 primary care practices in Australia for the period 2000-2012. The data was analysed for temporal trends and for associations between patient characteristics and completeness. General practitioners were surveyed to identify barriers to recording data and strategies to improve its completeness. Over the study period data completeness improved up to around 80% complete although the recording of weight remained poorer at 55%. T2D patients with Ischaemic Heart Disease were more likely to have their blood pressure recorded (OR 1.6, p=0.02). Practitioners reported not experiencing any major barriers to using their computer medical record system but did agree with some suggested strategies to improve record completeness. The completeness of routinely collected data suitable for input into computerised predictive models is improving although other dimensions of data quality need to be addressed. Copyright © 2016 Primary Care Diabetes Europe. Published by Elsevier Ltd. All rights reserved.
RodZ links MreB to cell wall synthesis to mediate MreB rotation and robust morphogenesis
Morgenstein, Randy M.; Bratton, Benjamin P.; Nguyen, Jeffrey P.; Ouzounov, Nikolay; Shaevitz, Joshua W.; Gitai, Zemer
2015-01-01
The rod shape of most bacteria requires the actin homolog, MreB. Whereas MreB was initially thought to statically define rod shape, recent studies found that MreB dynamically rotates around the cell circumference dependent on cell wall synthesis. However, the mechanism by which cytoplasmic MreB is linked to extracytoplasmic cell wall synthesis and the function of this linkage for morphogenesis has remained unclear. Here we demonstrate that the transmembrane protein RodZ mediates MreB rotation by directly or indirectly coupling MreB to cell wall synthesis enzymes. Furthermore, we map the RodZ domains that link MreB to cell wall synthesis and identify mreB mutants that suppress the shape defect of ΔrodZ without restoring rotation, uncoupling rotation from rod-like growth. Surprisingly, MreB rotation is dispensable for rod-like shape determination under standard laboratory conditions but is required for the robustness of rod shape and growth under conditions of cell wall stress. PMID:26396257
RodZ links MreB to cell wall synthesis to mediate MreB rotation and robust morphogenesis.
Morgenstein, Randy M; Bratton, Benjamin P; Nguyen, Jeffrey P; Ouzounov, Nikolay; Shaevitz, Joshua W; Gitai, Zemer
2015-10-06
The rod shape of most bacteria requires the actin homolog, MreB. Whereas MreB was initially thought to statically define rod shape, recent studies found that MreB dynamically rotates around the cell circumference dependent on cell wall synthesis. However, the mechanism by which cytoplasmic MreB is linked to extracytoplasmic cell wall synthesis and the function of this linkage for morphogenesis has remained unclear. Here we demonstrate that the transmembrane protein RodZ mediates MreB rotation by directly or indirectly coupling MreB to cell wall synthesis enzymes. Furthermore, we map the RodZ domains that link MreB to cell wall synthesis and identify mreB mutants that suppress the shape defect of ΔrodZ without restoring rotation, uncoupling rotation from rod-like growth. Surprisingly, MreB rotation is dispensable for rod-like shape determination under standard laboratory conditions but is required for the robustness of rod shape and growth under conditions of cell wall stress.
Truss beam having convex-curved rods, shear web panels, and self-aligning adapters
NASA Technical Reports Server (NTRS)
Fernandez, Ian M. (Inventor)
2013-01-01
A truss beam comprised of a plurality of joined convex-curved rods with self-aligning adapters (SAA) adhesively attached at each end of the truss beam is disclosed. Shear web panels are attached to adjacent pairs of rods, providing buckling resistance for the truss beam. The rods are disposed adjacent to each other, centered around a common longitudinal axis, and oriented so that adjacent rod ends converge to at least one virtual convergence point on the common longitudinal axis, with the rods' curvature designed to increase prevent buckling for the truss beam. Each SAA has longitudinal bores that provide self-aligning of the rods in the SAA, the self-aligning feature enabling creation of strong adhesive bonds between each SAA and the rods. In certain embodiments of the present invention, pultruded unidirectional carbon fiber rods are coupled with carbon fiber shear web panels and metal SAA(s), resulting in a lightweight, low-cost but strong truss beam that is highly resistant to buckling.
Final report, PT IP-535-C: Test of smaller VSR`s in DR reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vaughn, A.D.
1963-04-17
Because of rod-sticking problems at DR Reactor, a knuckle rod of B Reactor design was installed in vertical safety channel number 28. The substitute VSR, which has a smaller diameter than the original DR rod, has been tested for its operational feasibility including both drop time and reactivity effect. The reactivity effect of the rod was estimated by comparison of the reactivity transient caused by insertion of the specific B-type rod after scramming into the pile, with similar transients caused by normal vertical safety rod in an adjacent channel. This document lists the indicated relative control strength of the rodmore » as an empirical basis for future safety calculations. Results indicate that the B-type knuckel rod in DR reactor is about 80% as strong as a normal DR vertical safety rod if used in equivalent flux distribution and location; this makes it reasonable to assume that the local control strength of the B-type knuckel rod is 98 {mu}b.« less
Thermal Model of the Promoted Combustion Test
NASA Technical Reports Server (NTRS)
Jones, Peter D.
1996-01-01
Flammability of metals in high pressure, pure oxygen environments, such as rocket engine turbopumps, is commonly evaluated using the Promoted Combustion Test (PCT). The PCT emphasizes the ability of an ignited material to sustain combustion, as opposed to evaluating the sample's propensity to ignite in the first place. A common arrangement is a rod of the sample material hanging in a chamber in which a high pressure, pure oxygen environment is maintained. An igniter of some energetically combusting material is fixed to the bottom of the rod and fired. This initiates combustion, and the sample burns and melts at its bottom tip. A ball of molten material forms, and this ball detaches when it grows too large to be supported by surface tension with the rod. In materials which do not sustain combustion, the combustion then extinguishes. In materials which do sustain combustion, combustion re-initiates from molten residue left on the bottom of the rod, and the melt ball burns and grows until it detaches again. The purpose of this work is development of a PCT thermal simulation model, detailing phase change, melt detachment, and the several heat transfer modes. Combustion is modeled by a summary rate equation, whose parameters are identified by comparison to PCT results. The sensitivity of PCT results to various physical and geometrical parameters is evaluated. The identified combustion parameters may be used in design of new PCT arrangements, as might be used for flammability assessment in flow-dominated environments. The Haynes 214 nickel-based superalloy, whose PCT results are applied here, burns heterogeneously (fuel and oxidizer are of different phases; combustion takes place on the fuel surface). Heterogeneous combustion is not well understood. (In homogeneous combustion, the metal vaporizes, and combustion takes place in an analytically treatable cloud above the surface). Thermal modeling in heterogeneous combustion settings provides a means for linking test results more directly to detailed combustion mechanics, leading to improved data analysis, and improved understanding of heterogeneous combustion phenomena.
Agte, Silke; Savvinov, Alexey; Karl, Anett; Zayas-Santiago, Astrid; Ulbricht, Elke; Makarov, Vladimir I; Reichenbach, Andreas; Bringmann, Andreas; Skatchkov, Serguei N
2018-05-16
In this study, we show the capability of Müller glial cells to transport light through the inverted retina of reptiles, specifically the retina of the spectacled caimans. Thus, confirming that Müller cells of lower vertebrates also improve retinal light transmission. Confocal imaging of freshly isolated retinal wholemounts, that preserved the refractive index landscape of the tissue, indicated that the retina of the spectacled caiman is adapted for vision under dim light conditions. For light transmission experiments, we used a setup with two axially aligned objectives imaging the retina from both sides to project the light onto the inner (vitreal) surface and to detect the transmitted light behind the retina at the receptor layer. Simultaneously, a confocal microscope obtained images of the Müller cells embedded within the vital tissue. Projections of light onto several representative Müller cell trunks within the inner plexiform layer, i.e. (i) trunks with a straight orientation, (ii) trunks which are formed by the inner processes and (iii) trunks which get split into inner processes, were associated with increases in the intensity of the transmitted light. Projections of light onto the periphery of the Müller cell endfeet resulted in a lower intensity of transmitted light. In this way, retinal glial (Müller) cells support dim light vision by improving the signal-to-noise ratio which increases the sensitivity to light. The field of illuminated photoreceptors mainly include rods reflecting the rod dominance of the of tissue. A subpopulation of Müller cells with downstreaming cone cells led to a high-intensity illumination of the cones, while the surrounding rods were illuminated by light of lower intensity. Therefore, Müller cells that lie in front of cones may adapt the intensity of the transmitted light to the different sensitivities of cones and rods, presumably allowing a simultaneous vision with both receptor types under dim light conditions. Copyright © 2018 Elsevier Ltd. All rights reserved.
Analysis of transient fission gas behaviour in oxide fuel using BISON and TRANSURANUS
Barani, T.; Bruschi, E.; Pizzocri, D.; ...
2017-01-03
The modelling of fission gas behaviour is a crucial aspect of nuclear fuel analysis in view of the related effects on the thermo-mechanical performance of the fuel rod, which can be particularly significant during transients. Experimental observations indicate that substantial fission gas release (FGR) can occur on a small time scale during transients (burst release). To accurately reproduce the rapid kinetics of burst release in fuel performance calculations, a model that accounts for non-diffusional mechanisms such as fuel micro-cracking is needed. In this work, we present and assess a model for transient fission gas behaviour in oxide fuel, which ismore » applied as an extension of diffusion-based models to allow for the burst release effect. The concept and governing equations of the model are presented, and the effect of the newly introduced parameters is evaluated through an analytic sensitivity analysis. Then, the model is assessed for application to integral fuel rod analysis. The approach that we take for model assessment involves implementation in two structurally different fuel performance codes, namely, BISON (multi-dimensional finite element code) and TRANSURANUS (1.5D semi-analytic code). The model is validated against 19 Light Water Reactor fuel rod irradiation experiments from the OECD/NEA IFPE (International Fuel Performance Experiments) database, all of which are simulated with both codes. The results point out an improvement in both the qualitative representation of the FGR kinetics and the quantitative predictions of integral fuel rod FGR, relative to the canonical, purely diffusion-based models, with both codes. The overall quantitative improvement of the FGR predictions in the two codes is comparable. Furthermore, calculated radial profiles of xenon concentration are investigated and compared to experimental data, demonstrating the representation of the underlying mechanisms of burst release by the new model.« less
Early-onset scoliosis: current treatment.
Cunin, V
2015-02-01
Early-onset scoliosis, which appears before the age of 10, can be due to congenital vertebral anomalies, neuromuscular diseases, scoliosis-associated syndromes, or idiopathic causes. It can have serious consequences for lung development and significantly reduce the life expectancy compared to adolescent scoliosis. Extended posterior fusion must be avoided to prevent the crankshaft phenomenon, uneven growth of the trunk and especially restrictive lung disease. Conservative (non-surgical) treatment is used first. If this fails, fusionless surgery can be performed to delay the final fusion procedure until the patient is older. The gold standard delaying surgical treatment is the implantation of growing rods as described by Moe and colleagues in the mid-1980s. These rods, which are lengthened during short surgical procedures at regular intervals, curb the scoliosis progression until the patient reaches an age where fusion can be performed. Knowledge of this technique and its complications has led to several mechanical improvements being made, namely use of rods that can be distracted magnetically on an outpatient basis, without the need for anesthesia. Devices based on the same principle have been designed that preferentially attach to the ribs to specifically address chest wall and spine dysplasia. The second category of surgical devices consists of rods used to guide spinal growth that do not require repeated surgical procedures. The third type of fusionless surgical treatment involves slowing the growth of the scoliosis convexity to help reduce the Cobb angle. The indications are constantly changing. Improvements in surgical techniques and greater surgeon experience may help to reduce the number of complications and make this lengthy treatment acceptable to patients and their family. Long-term effects of surgery on the Cobb angle have not been compared to those involving conservative "delaying" treatments. Because the latter has fewer complications associated with it than surgery, it should be the first-line treatment for most cases of early-onset scoliosis. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Techniques and equipment for assessing the structural integrity of subterranean tower anchor rods
Hinz, William R.; Parker, Matthew J.
2001-01-01
Techniques and equipment for evaluating structural integrity of buried anchor rods in situ are disclosed. The techniques avoid excavation of soil and avoid, or at least reduce, the possibility of damage to the rods or the concrete in which they may be embedded when evaluations are conducted. Instead, ultrasonic energy is transmitted through the rod from a portable transducer, and returned energy (in either or both of direct and mode-converted states) may be analyzed to assist in detecting flaws, corrosion, wastage, or other degradation of the rod. Data from a field evaluation may be compared with baseline data maintained either for a specific rod or for rods of similar composition and length (or both), and periodic field evaluations of a rod may be used to analyze trends in its structure over time.
NASA Astrophysics Data System (ADS)
Tao, Yuefei
Organic electronics are of great interest in manufacturing light weight, mechanical flexible, and inexpensive large area devices. While significant improvements have been made over the last several years and it is now clear that morphology on the lengthscale of exciton diffusion (10nm) is of crucial importance, a clear relationship between structure and device properties has not emerged. This lack of understanding largely emerges from an inability to control morphology on this lengthscale. This thesis will center around an approach, based on block copolymer self-assembly, to generate equilibrium nanostructures on the 10 nm lengthscale of exciton diffusion and study their effects on device performance. Self-assembly of semiconducting block copolymers is complicated by the non-classical chain shape of conjugated polymers. Unlike classical polymers, the chains do not assume a Gaussian coil shape which is stretched near block copolymer interfaces, instead the chains are elongated and liquid crystalline. Previous work has demonstrated how these new molecular interactions and shapes control the phase diagram of so-called rod-coil block copolymers. Here, we will focus on controlling domain size, orientation, and chemical structure. While domain size can be controlled directly through molecular weight, this requires significant additional synthesis of domain size is to be varied. Here, the domain size is controlled by blending homopolymers into a self-assembling rod-coil block copolymer. When coil-like blocks are incorporated, the domains swell, as expected. When rod-like blocks are incorporated, they interdigitate with the rods of the block copolymers. This results in an increase in interfacial area which forces the coils to rearrange and an overall decrease in domain size with increasing rod content. Control over lamellar orientation is crucial in order to design and control charge transport pathways and exciton recombination or separation interfaces. While numerous techniques have been demonstrated for classical block copolymers, the pi conjugation in the rod blocks allow for additional control mechanisms. Liquid crystals are traditionally aligned in magnetic fields. Here, it is demonstrated that if the rod-like blocks are aligned unidirectionally, the block copolymer interfaces follow to create macroscopic alignment of the nanostructures. Organic Light Emitting Diodes (OLEDs) are generally composed of electron transporting and hole transporting moieties to balance charge recombination. Here, a new multifunctional bipolar rod-coil block copolymer containing the hole transporting and electron transporting materials is synthesized. Self-assembly of this new block copolymer results in 15nm lamellae oriented in grains both parallel and perpendicula to the anode. The self-assembled block copolymer shows superior device performance to controls consisting of a luminescent, analogous homopolymer, and a blend of the two component homopolymers. The effects of the morphologies and chemical structure on photovoltaics is explored with a rod-coil block copolymer, (poly(3-hexylthiophene-b-acrylic perylene)). By varying the kinetics of self-assembly through processing, the block copolymer can be disordered, ordered with only short range registry between the nanodomains, or with long-range order. The short range ordered samples showed the best device performance suggesting that the connectivity that is a biproduct of poor order is beneficial for device performance.
Real-time pulse oximetry artifact annotation on computerized anaesthetic records.
Gostt, Richard Karl; Rathbone, Graeme Dennis; Tucker, Adam Paul
2002-01-01
Adoption of computerised anaesthesia record keeping systems has been limited by the concern that they record artifactual data and accurate data indiscriminately. Data resulting from artifacts does not reflect the patient's true condition and presents a problem in later analysis of the record, with associated medico-legal implications. This study developed an algorithm to automatically annotate pulse oximetry artifacts and sought to evaluate the algorithm's accuracy in routine surgical procedures. MacAnaesthetist is a semi-automatic anaesthetic record keeping system developed for the Apple Macintosh computer, which incorporated an algorithm designed to automatically detect pulse oximetry artifacts. The algorithm labeled artifactual oxygen saturation values < 90%. This was done in real-time by analyzing physiological data captured from a Datex AS/3 Anaesthesia Monitor. An observational study was conducted to evaluate the accuracy of the algorithm during routine surgical procedures (n = 20). An anaesthetic record was made by an anaesthetist using the Datex AS/3 record keeper, while a second anaesthetic record was produced in parallel using MacAnaesthetist. A copy of the Datex AS/3 record was kept for later review by a group of anaesthetists (n = 20), who judged oxygen saturation values < 90% to be either genuine or artifact. MacAnaesthetist correctly labeled 12 out of 13 oxygen saturations < 90% (92.3% accuracy). A post-operative review of the Datex AS/3 anaesthetic records (n = 8) by twenty anaesthetists resulted in 127 correct responses out of total of 200 (63.5% accuracy). The remaining Datex AS/3 records (n = 12) were not reviewed, as they did not contain any oxygen saturations <90%. The real-time artifact detection algorithm developed in this study was more accurate than anaesthetists who post-operatively reviewed records produced by an existing computerised anaesthesia record keeping system. Algorithms have the potential to more accurately identify and annotate artifacts on computerised anaesthetic records, assisting clinicians to more correctly interpret abnormal data.
CONTROL RODS FOR NUCLEAR REACTORS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bell, F.R.
1963-01-16
A means for controlling the control rod in emergency, when it is desired to shutdown the reactor with the shortest possible delay, is described. When the emergency occurs the control rod is allowed to drop freely under gravity from the control rod support tube into the bore in the reactor core. A normal shutdown is reached almost at the lowest rod position. In the shut-down position and also below it, the control rod had its full effect of reducing the level of activity in the core. When the shut-down position was reached, a brake came into action to decelerate themore » rod and reduce shock and the likelihood of damage. (C.E.S.)« less
CRDM with separate SCRAM latch engagement and locking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dodd, Christopher D.; DeSantis, Paul K.; Stambaugh, Kevin J.
A control rod drive mechanism (CRDM) configured to latch onto the lifting rod of a control rod assembly and including separate latch engagement and latch holding mechanisms. A CRDM configured to latch onto the lifting rod of a control rod assembly and including a four-bar linkage closing the latch, wherein the four-bar linkage biases the latch closed under force of gravity.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-07
... Steel Wire Rod From Mexico: Notice of Final Results of Antidumping Duty Administrative Review AGENCY... results of the administrative review of the antidumping duty order on carbon and certain alloy steel wire rod (wire rod) from Mexico.\\1\\ This review covers imports of wire rod from ArcelorMittal Las Truchas...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-24
...-805, A-274-804, A-823-812] Carbon and Certain Alloy Steel Wire Rod From Brazil, Indonesia, Mexico... on carbon and certain alloy steel wire rod (``wire rod'') from Brazil, Indonesia, Mexico, Moldova... published the notice of initiation of the sunset reviews of the antidumping duty orders on wire rod from...
Summary report, Flexible VSR`s and VSR channel sleeve development programs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kempf, F.J.
1963-11-15
(VSR = vertical safety rod.) This report summarizes results of development programs which have evaluated vertical rod channel sleeving materials and provided flexible vertical rods, acceptable for both interim use before rod channel sleeving, and for subsequent use in sleeved channels. B{sub 4}C is the rod material; graphite and Al oxide are among the sleeve materials.
[Experimental study of recovery force of surface-modified TiNi memory alloy rod].
Wang, Aiyuan; Peng, Jiang; Zhang, Xian; Xu, Wenjin; Wang, Xing; Sun, Minxue; Lu, Shibi
2006-08-01
The recovery force of Ti-Nb coated and uncoated TiNi shape memory alloy rods was investigated. The rods were 6.0 mm, 6.5 mm and 7.0 mm in diameter respectively. The mean transition temperature was 33.0 degrees C. The rods were stored at -18 degrees C and pre-bent with a three-point bending fixture, the span was 20. 0 centimeters and the deflections were 5.0 mm, 10.0 mm, 15.0 mm and 20.0 mm, respectively. The rods were then heated in a constant temperature saline solution chamber. The experimental temperature was 37.0 C and 50.0 C respectively. The recovery force was measured in a constant displacement mode on biomaterial test machine. The results showed that the recovery force of the memory alloy rod increased with increasing recovery temperature, rod diameter and deformation of both Ti-Nb coated and uncoated surface. The recovery force of Ti-Nb coated rods of 6.0 and 6.5 millimeter in diameter was lower than the uncoated rods in the same diameter. However, the recovery force of 7.0-mm-diameter rods showed no significant difference between coated and uncoated surface.
Experimental Study on Surrogate Nuclear Fuel Rods under Reversed Cyclic Bending
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Hong; Wang, Jy-An John
The mechanical behavior of spent nuclear fuel (SNF) rods under reversed cyclic bending or bending fatigue must be understood to evaluate their vibration integrity in a transportation environment. This is especially important for high-burnup fuels (>45 GWd/MTU), which have the potential for increased structural damage. It has been demonstrated that the bending fatigue of SNF rods can be effectively studied using surrogate rods. In this investigation, surrogate rods made of stainless steel (SS) 304 cladding and aluminum oxide pellets were tested under load or moment control at a variety of amplitude levels at 5 Hz using the Cyclic Integrated Reversible-Bendingmore » Fatigue Tester developed at Oak Ridge National Laboratory. The behavior of the rods was further characterized using flexural rigidity and hysteresis data, and fractography was performed on the failed rods. The proposed surrogate rods captured many of the characteristics of deformation and failure mode observed in SNF, including the linear-to-nonlinear deformation transition and large residual curvature in static tests, PPI and PCMI failure mechanisms, and large variation in the initial structural condition. Rod degradation was measured and characterized by measuring the flexural rigidity; the degradation of the rigidity depended on both the moment amplitude applied and the initial structural condition of the rods. It was also shown that a cracking initiation site can be located on the internal surface or the external surface of cladding. Finally, fatigue damage to the bending rods can be described in terms of flexural rigidity, and the fatigue life of rods can be predicted once damage model parameters are properly evaluated. The developed experimental approach, test protocol, and analysis method can be used to study the vibration integrity of SNF rods in the future.« less
[Development and current situation of reconstruction methods following total sacrectomy].
Huang, Siyi; Ji, Tao; Guo, Wei
2018-05-01
To review the development of the reconstruction methods following total sacrectomy, and to provide reference for finding a better reconstruction method following total sacrectomy. The case reports and biomechanical and finite element studies of reconstruction following total sacrectomy at home and abroad were searched. Development and current situation were summarized. After developing for nearly 30 years, great progress has been made in the reconstruction concept and fixation techniques. The fixation methods can be summarized as the following three strategies: spinopelvic fixation (SPF), posterior pelvic ring fixation (PPRF), and anterior spinal column fixation (ASCF). SPF has undergone technical progress from intrapelvic rod and hook constructs to pedicle and iliac screw-rod systems. PPRF and ASCF could improve the stability of the reconstruction system. Reconstruction following total sacrectomy remains a challenge. Reconstruction combining SPF, PPRF, and ASCF is the developmental direction to achieve mechanical stability. How to gain biological fixation to improve the long-term stability is an urgent problem to be solved.
Single Mode ZnO Whispering-Gallery Submicron Cavity and Graphene Improved Lasing Performance.
Li, Jitao; Lin, Yi; Lu, Junfeng; Xu, Chunxiang; Wang, Yueyue; Shi, Zengliang; Dai, Jun
2015-07-28
Single-mode ultraviolet (UV) laser of ZnO is still in challenge so far, although it has been paid great attention along the past decades. In this work, single-mode lasing resonance was realized in a submicron-sized ZnO rod based on serially varying the dimension of the whispering-gallery mode (WGM) cavities. The lasing performance, such as the lasing quality factor (Q) and the lasing intensity, was remarkably improved by facilely covering monolayer graphene on the ZnO submicron-rod. The mode structure evolution from multimodes to single-mode was investigated systematically based on the total internal-wall reflection of the ZnO microcavities. Graphene-induced optical field confinement and lasing emission enhancement were revealed, indicating an energy coupling between graphene SP and ZnO exciton emission. This result demonstrated the response of graphene in the UV wavelength region and extended its potential applications besides many previous reports on the multifunctional graphene/semiconductor hybrid materials and devices in advanced electronics and optoelectronics areas.
ELECTROMAGNETIC APPARATUS FOR MOVING A ROD
Young, J.N.
1958-04-22
An electromagnetic apparatus for moving a rod-like member in small steps in either direction is described. The invention has particular application in the reactor field where the reactor control rods must be moved only a small distance and where the use of mechanical couplings is impractical due to the high- pressure seals required. A neutron-absorbing rod is mounted in a housing with gripping uaits that engage the rod, and coils for magnetizing the gripping units to make them grip, shift, and release the rod are located outside the housing.
Chapellier, R.A.; Rogers, I.
1961-06-27
Accurate and controlled drive for the control rod is from an electric motor. A hydraulic arrangement is provided to balance a piston against which a control rod is urged by the application of fluid pressure. The electric motor drive of the control rod for normal operation is made through the aforementioned piston. In the event scramming is required, the fluid pressure urging the control rod against the piston is relieved and an opposite fluid pressure is applied. The lack of mechanical connection between the electric motor and control rod facilitates the scramming operation.
CONTROL SYSTEM FOR NEUTRONIC REACTORS
Crever, F.E.
1962-05-01
BS>A slow-acting shim rod for control of major variations in reactor neutron flux and a fast-acting control rod to correct minor flux variations are employed to provide a sensitive, accurate control system. The fast-acting rod is responsive to an error signal which is produced by changes in the neutron flux from a predetermined optimum level. When the fast rod is thus actuated in a given direction, means is provided to actuate the slow-moving rod in that direction to return the fast rod to a position near the midpoint of its control range. (AEC)
Forecasting of construction and demolition waste in Brazil.
Paz, Diogo Hf; Lafayette, Kalinny Pv
2016-08-01
The objective of this article is to develop a computerised tool (software) that facilitates the analysis of strategies for waste management on construction sites through the use of indicators of construction and demolition waste generation. The development involved the following steps: knowledge acquisition, structuring the system, coding and system evaluation. The step of knowledge acquisition aims to provide subsidies for the representation of them through models. In the step of structuring the system, it was presented the structuring and formalisation of knowledge for the development of the system, and has two stages: the construction of the conceptual model and the subsequent instantiation of the model. The coding system aims to implement (code) the conceptual model developed in a model played by computer (digital). The results showed that the system is very useful and applicable in construction sites, helping to improve the quality of waste management, and creating a database that will support new research. © The Author(s) 2016.
Lesson of the month 1: Lobar pulmonary consolidation in an immunocompromised host.
Reynolds, Daniel J; Andersen, Carl A; Hoskote, Sumedh S; Lee, Hee Eun; Raghunathan, Aditya; Kalra, Sanjay; Limper, Andrew H
2016-12-01
A 19-year-old male with a history of idiopathic panuveitis, currently taking methotrexate and infliximab, presented to our institution with 6 weeks of cough, dyspnoea and fevers. He had failed outpatient antimicrobial therapy. Computerised tomography (CT) of the chest revealed the presence of a lobar pneumonia and he was treated with broad spectrum antibiotics, which did not improve his symptoms. Bronchoalveolar lavage was performed with a transbronchial lung biopsy because of the diagnostic uncertainty of the patient's presentation. Pathology revealed non-budding yeasts, consistent with Pneumocystis Serological and urine studies were positive for both Histoplasma and Blastomyces The diagnosis of Histoplasma pneumonia was made because of the presentation being inconsistent with Pneumocystis pneumonia, and serology, urine and pathology testing being more consistent with Histoplasma The patient was treated with oral itraconazole and was doing well at follow-up 12 weeks after hospitalisation. © Royal College of Physicians 2016. All rights reserved.
Underreporting of viral encephalitis and viral meningitis, Ireland, 2005-2008.
Kelly, Tara A; O'Lorcain, Piaras; Moran, Joanne; Garvey, Patricia; McKeown, Paul; Connell, Jeff; Cotter, Suzanne
2013-01-01
Viral encephalitis (VE) and viral meningitis (VM) have been notifiable infectious diseases under surveillance in the Republic of Ireland since 1981. Laboratories have reported confirmed cases by detection of viral nucleic acid in cerebrospinal fluid since 2004. To determine the prevalence of these diseases in Ireland during 2005-2008, we analyzed 3 data sources: Hospital In-patient Enquiry data (from hospitalized following patients discharge) accessed through Health Intelligence Ireland, laboratory confirmations from the National Virus Reference Laboratory, and events from the Computerised Infectious Disease Reporting surveillance system. We found that the national surveillance system underestimates the incidence of these diseases in Ireland with a 10-fold higher VE hospitalization rate and 3-fold higher VM hospitalization rate than the reporting rate. Herpesviruses were responsible for most specified VE and enteroviruses for most specified VM from all 3 sources. Recommendations from this study have been implemented to improve the surveillance of these diseases in Ireland.
Cadetti, Lucia; Bryson, Eric J.; Ciccone, Cory A.; Rabl, Katalin; Thoreson, Wallace B.
2008-01-01
We examined the contribution of calcium-induced calcium release (CICR) to synaptic transmission from rod photoreceptor terminals. Whole-cell recording and confocal calcium imaging experiments were conducted on rods with intact synaptic terminals in a retinal slice preparation from salamander. Low concentrations of ryanodine stimulated calcium increases in rod terminals, consistent with the presence of ryanodine receptors. Application of strong depolarizing steps (−70 to −10 mV) exceeding 200 ms or longer in duration evoked a wave of calcium that spread across the synaptic terminals of voltage-clamped rods. This secondary calcium increase was blocked by high concentrations of ryanodine, indicating it was due to CICR. Ryanodine (50 μM) had no significant effect on rod calcium current (Ica) although it slightly diminished rod light-evoked voltage responses. Bath application of 50 μM ryanodine strongly inhibited light-evoked currents in horizontal cells. Whether applied extracellularly or delivered into the rod cell through the patch pipette, ryanodine (50 μM) also inhibited excitatory post-synaptic currents (EPSCs) evoked in horizontal cells by depolarizing steps applied to rods. Ryanodine caused a preferential reduction in the later portions of EPSCs evoked by depolarizing steps of 200 ms or longer. These results indicate that CICR enhances calcium increases in rod terminals evoked by sustained depolarization, which in turn acts to boost synaptic exocytosis from rods. PMID:16819987
Ito, Manabu; Abumi, Kuniyoshi; Kotani, Yoshihisa; Takahata, Masahiko; Sudo, Hideki; Hojo, Yoshihiro; Minami, Akio
2010-03-01
The authors present a new posterior correction technique consisting of simultaneous double-rod rotation using 2 contoured rods and polyaxial pedicle screws with or without Nesplon tapes. The purpose of this study is to introduce the basic principles and surgical procedures of this new posterior surgery for correction of adolescent idiopathic scoliosis. Through gradual rotation of the concave-side rod by 2 rod holders, the convex-side rod simultaneously rotates with the the concave-side rod. This procedure does not involve any force pushing down the spinal column around the apex. Since this procedure consists of upward pushing and lateral translation of the spinal column with simultaneous double-rod rotation maneuvers, it is simple and can obtain thoracic kyphosis as well as favorable scoliosis correction. This technique is applicable not only to a thoracic single curve but also to double major curves in cases of adolescent idiopathic scoliosis.
30. Engine controls and valve gear, looking aft on main ...
30. Engine controls and valve gear, looking aft on main (promenade) deck level. Threaded admission valve lift rods (two at immediate left of chronometer) permit adjustment of valve timing in lower and upper admission valves of cylinder (left rod controls lower valve, right rod upper valve). Valve rods are lifted by jaw-like "wipers" during operation. Exhaust valve lift rods and wipers are located to right of chronometer. Crank at extreme right drives valve wiper shaft when engaged to end of eccentric rod, shown under "Crank Indicator" dial. Pair of handles to immediate left of admission valve rods control condenser water valves; handles to right of exhaust valve rods control feedwater flow to boilers from pumps. Gauges indicate boiler pressure (left) and condenser vacuum (right); "Crank Indicator" on wall aids engineer in keeping engine crank off "dead-center" at stop so that engine may be easily restarted. - Steamboat TICONDEROGA, Shelburne Museum Route 7, Shelburne, Chittenden County, VT
Measurements of lightning rod responses to nearby strikes
NASA Astrophysics Data System (ADS)
Moore, C. B.; Aulich, G. D.; Rison, W.
2000-05-01
Following Benjamin Franklin's invention of the lightning rod, based on his discovery that electrified objects could be discharged by approaching them with a metal needle in hand, conventional lightning rods in the U.S. have had sharp tips. In recent years, the role of the sharp tip in causing a lightning rod to act as a strike receptor has been questioned leading to experiments in which pairs of various sharp-tipped and blunt rods have been exposed beneath thunderclouds to determine the better strike receptor. After seven years of tests, none of the sharp Franklin rods or of the so-called “early streamer emitters” has been struck, but 12 blunt rods with tip diameters ranging from 12.7 mm to 25.4 mm have taken strikes. Our field experiments and our analyses indicate that the strike-reception probabilities of Franklin's rods are greatly increased when their tips are made moderately blunt.
Terminal ballistics of a reduced-mass penetrator. Final report, January 1990--December 1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silsby, G.F.
1996-07-01
This report presents the results of an experimental program to examine the performance of a reduced-mass concept penetrator impacting semi-infinite rolled homogeneous armor (RHA) at normal incidence. The reduced-mass penetrator used in this program is a solid tungsten alloy rod with eight holes drilled parallel to its axis, equally spaced on a circle, with axes parallel to the rod axis. Its performance was contrasted with baseline data for length-to- diameter ratios (L/D) 4 and 5 solid tungsten alloy penetrators. Striking velocity was nominally 1.6 km/s. A determined effort to reduce the scatter in the data by analysis of collateral datamore » from the US Army Research Laboratory (ARL) and literature sources suggested only a rather weak influence of L/D on penetration even at L/Ds approaching 1 and provided a tentative relationship to remove the influence of target lateral edge effects. It tightened up the holed-out rod data enough to be able to conclude with a moderate degree of certainty that there was no improvement in penetration as suggested by a simplistic density law model. A companion work by Kimsey of ARL examines the performance of this novel penetrator concept computationally, using the Eulerian code CTH. His work explains the possible causes of reduced performance suggested by analysis by Zook and Frank of ARL, though with some relative improvement in performance at higher velocities.« less
Fuel bundle design for enhanced usage of plutonium fuel
Reese, Anthony P.; Stachowski, Russell E.
1995-01-01
A nuclear fuel bundle includes a square array of fuel rods each having a concentration of enriched uranium and plutonium. Each rod of an interior array of the rods also has a concentration of gadolinium. The interior array of rods is surrounded by an exterior array of rods void of gadolinium. By this design, usage of plutonium in the nuclear reactor is enhanced.
Fuel bundle design for enhanced usage of plutonium fuel
Reese, A.P.; Stachowski, R.E.
1995-08-08
A nuclear fuel bundle includes a square array of fuel rods each having a concentration of enriched uranium and plutonium. Each rod of an interior array of the rods also has a concentration of gadolinium. The interior array of rods is surrounded by an exterior array of rods void of gadolinium. By this design, usage of plutonium in the nuclear reactor is enhanced. 10 figs.
Linear motion device and method for inserting and withdrawing control rods
Smith, Jay E.
1984-01-01
A linear motion device, more specifically a control rod drive mechanism (CRDM) for inserting and withdrawing control rods into a reactor core, is capable of independently and sequentially positioning two sets of control rods with a single motor stator and rotor. The CRDM disclosed can control more than one control rod lead screw without incurring a substantial increase in the size of the mechanism.
Prism adaptation does not alter object-based attention in healthy participants.
Bultitude, Janet H; List, Alexandra; Aimola Davies, Anne M
2013-01-01
Hemispatial neglect ('neglect') is a disabling condition that can follow damage to the right side of the brain, in which patients show difficulty in responding to or orienting towards objects and events that occur on the left side of space. Symptoms of neglect can manifest in both space- and object-based frames of reference. Although patients can show a combination of these two forms of neglect, they are considered separable and have distinct neurological bases. In recent years considerable evidence has emerged to demonstrate that spatial symptoms of neglect can be reduced by an intervention called prism adaptation. Patients point towards objects viewed through prismatic lenses that shift the visual image to the right. Approximately five minutes of repeated pointing results in a leftward recalibration of pointing and improved performance on standard clinical tests for neglect. The understanding of prism adaptation has also been advanced through studies of healthy participants, in whom adaptation to leftward prismatic shifts results in temporary neglect-like performance. Here we examined the effect of prism adaptation on the performance of healthy participants who completed a computerised test of space- and object-based attention. Participants underwent adaptation to leftward- or rightward-shifting prisms, or performed neutral pointing according to a between-groups design. Significant pointing after-effects were found for both prism groups, indicating successful adaptation. In addition, the results of the computerised test revealed larger reaction-time costs associated with shifts of attention between two objects compared to shifts of attention within the same object, replicating previous work. However there were no differences in the performance of the three groups, indicating that prism adaptation did not influence space- or object-based attention for this task. When combined with existing literature, the results are consistent with the proposal that prism adaptation may only perturb cognitive functions for which normal baseline performance is already biased.
Currie, Kay; McCallum, Jacqueline; Murray, John; Scott, Janine; Strachan, Evelyn; Yates, Lynda; Wright, Marty
2014-05-01
Reducing avoidable nursing student attrition is an international challenge. A pattern of falling attendance is recognised as a frequent precursor to withdrawal from nursing programmes. To address concerns regarding nursing student attrition, the Scottish Government implemented a pilot project for a centralised Computerised Absence Management and Monitoring System (CAMMS). The CAMMS adopted an 'assertive outreach' approach, contacting students every two weeks via colour coded letters to tell them whether their attendance was 'excellent', 'good, but potentially causing concern'; or 'warning; attendance concerns/contact academic staff for support'. This article reports key findings from an evaluation of CAMMS. To explore the perceived impact of CAMMS on student support and attrition, from the perspectives of academic and administrative staff and students. Mixed methods evaluation design. Three large geographically dispersed Schools of Nursing in Scotland. 83 students; 20 academic staff; and 3 lead administrators. On-line cohort survey of academic staff and students; structured interviews with lead administrators. Findings reflected a spectrum of negative and positive views of CAMMS. Students who are attending regularly seem pleased that their commitment is recognised. Lecturers who teach larger groups report greater difficulty getting to know students individually and acknowledge the benefit of identifying potential attendance concerns at an early stage. Conversely, some students who received a 'warning' letter were frequently annoyed or irritated, rather than feeling supported. Increased staff workload resulted in negative perceptions and a consequent reluctance to use CAMMS. However, students who were causing concern reported subsequent improvement in attendance. CAMMS has the potential to identify 'at-risk' students at an early stage; however, the system should have flexibility to tailor automatically generated letters in response to individual circumstances, to avoid student frustration. Further research on the longer term impact of CAMMS on attrition rates is warranted. © 2013.
Andrewes, Holly; Kenicer, David; McClay, Carrie-Anne; Williams, Christopher
2013-01-01
Objective This study aimed to identify if patients have adequate access to Computerised Cognitive Behavioural Therapy (cCBT) programmes in all mental health trusts across England. Design The primary researcher contacted a targeted sample of information technology (IT) leads in each mental health trust in England to complete the survey. Setting Telephone, email and postal mail were used to contact an IT lead or nominated expert from each mental health trust. Participants 48 of the 56 IT experts from each mental health trust in England responded. The experts who were chosen had sufficient knowledge of the infrastructure, technology, policies and regulations to answer all survey questions. Results 77% of trusts provided computers for direct patient use, with computers in all except one trust meeting the specifications to access cCBT. However, 24% of trusts acknowledged that the number of computers provided was insufficient to provide a trust-wide service. 71% stated that the bandwidth available was adequate to provide access to cCBT sites, yet for many trusts, internet speed was identified as unpredictable and variable between locations. IT policies in only 56% of the trusts allowed National Health Service (NHS) staff to directly support patients as they complete cCBT courses via emails to the patients’ personal email account. Only 37% allowed support via internet video calls, and only 9% allowed support via instant messaging services. Conclusions Patient access to cCBT in English NHS mental health trusts is limited by the inadequate number of computers provided to patients, unpredictable bandwidth speed and inconsistent IT policies, which restrict patients from receiving the support needed to maximise the success of this therapy. English NHS mental health trusts need to alter IT policy and improve resources to reduce the waiting time for psychological resources required for patients seeking this evidence-based therapy. PMID:23377995
Prism adaptation does not alter object-based attention in healthy participants
Bultitude, Janet H.
2013-01-01
Hemispatial neglect (‘neglect’) is a disabling condition that can follow damage to the right side of the brain, in which patients show difficulty in responding to or orienting towards objects and events that occur on the left side of space. Symptoms of neglect can manifest in both space- and object-based frames of reference. Although patients can show a combination of these two forms of neglect, they are considered separable and have distinct neurological bases. In recent years considerable evidence has emerged to demonstrate that spatial symptoms of neglect can be reduced by an intervention called prism adaptation. Patients point towards objects viewed through prismatic lenses that shift the visual image to the right. Approximately five minutes of repeated pointing results in a leftward recalibration of pointing and improved performance on standard clinical tests for neglect. The understanding of prism adaptation has also been advanced through studies of healthy participants, in whom adaptation to leftward prismatic shifts results in temporary neglect-like performance. Here we examined the effect of prism adaptation on the performance of healthy participants who completed a computerised test of space- and object-based attention. Participants underwent adaptation to leftward- or rightward-shifting prisms, or performed neutral pointing according to a between-groups design. Significant pointing after-effects were found for both prism groups, indicating successful adaptation. In addition, the results of the computerised test revealed larger reaction-time costs associated with shifts of attention between two objects compared to shifts of attention within the same object, replicating previous work. However there were no differences in the performance of the three groups, indicating that prism adaptation did not influence space- or object-based attention for this task. When combined with existing literature, the results are consistent with the proposal that prism adaptation may only perturb cognitive functions for which normal baseline performance is already biased. PMID:24715960
Nuclear core and fuel assemblies
Downs, Robert E.
1981-01-01
A fast flux nuclear core of a plurality of rodded, open-lattice assemblies having a rod pattern rotated relative to a rod support structure pattern. Elongated fuel rods are oriented on a triangular array and laterally supported by grid structures positioned along the length of the assembly. Initial inter-assembly contact is through strongbacks at the corners of the support pattern and peripheral fuel rods between adjacent assemblies are nested so as to maintain a triangular pitch across a clearance gap between the other portions of adjacent assemblies. The rod pattern is rotated relative to the strongback support pattern by an angle .alpha. equal to sin .sup.-1 (p/2c), where p is the intra-assembly rod pitch and c is the center-to-center spacing among adjacent assemblies.
Reactor control rod timing system. [LMFBR
Wu, P.T.K.
1980-03-18
A fluid driven jet-edge whistle timing system is described for control rods of a nuclear reactor for producing real-time detection of the timing of each control rod in its scram operation. An important parameter in reactor safety, particularly for liquid metal fast breeder reactors (LMFBR), is the time deviation between the time the control rod is released and the time the rod actually reaches the down position. The whistle has a nearly pure tone signal with center frequency (above 100 kHz) far above the frequency band in which the energy of the background noise is concentrated. Each control rod can be fitted with a whistle with a different frequency so that there is no ambiguity in differentiating the signal from each control rod.
Reactor control rod timing system
Wu, Peter T. K.
1982-01-01
A fluid driven jet-edge whistle timing system for control rods of a nuclear reactor for producing real-time detection of the timing of each control rod in its scram operation. An important parameter in reactor safety, particularly for liquid metal fast breeder reactors (LMFBR), is the time deviation between the time the control rod is released and the time the rod actually reaches the down position. The whistle has a nearly pure tone signal with center frequency (above 100 kHz) far above the frequency band in which the energy of the background noise is concentrated. Each control rod can be fitted with a whistle with a different frequency so that there is no ambiguity in differentiating the signal from each control rod.
Convergent synthesis of multiporphyrin light-harvesting rods
Lindsey, Jonathan S.; Loewe, Robert S.
2003-08-05
The present invention provides a convergent method for the synthesis of light harvesting rods. The rods are oligomers of the formula A.sup.1 (A.sup.b+1).sub.b, wherein b is at least 1, A.sup.1 through A.sup.b+1 are covalently coupled rod segments, and each rod segment A.sup.1 through A.sup.1+b comprises a compound of the formula X.sup.1 (X.sup.m+1).sub.m wherein m is at least 1 and X.sup.1 through X.sup.m+1 are covalently coupled porphyrinic macrocycles. Light harvesting arrays and solar cells containing such light harvesting rods are also described, along with intermediates useful in such methods and rods produced by such methods.
Birefringence-balanced polarimetric optical fiber sensor for high-temperature measurements
NASA Technical Reports Server (NTRS)
Wang, Anbo; Wang, George Z.; Murphy, Kent A.; Claus, Richard O.
1992-01-01
A birefringence-balanced polarimetric multimode fiber temperature sensor is proposed and demonstrated. Two single-crystal sapphire rods are incorporated into the sensor head. They are connected end to end in such a way that the slow axis of the first rod is aligned with the fast axis of the second rod, referred to as the referencing rod. Since the lengths of the two rods are chosen to be almost the same, the original birefringence of the first rod is balanced by that of the second rod. A light-emitting diode serves as the light source. This sensor has been experimentally demonstrated for high-temperature measurements as high as 1500 C. A sensitivity of 5 C has been obtained.
REACTOR CONTROL ROD OPERATING SYSTEM
Miller, G.
1961-12-12
A nuclear reactor control rod mechanism is designed which mechanically moves the control rods into and out of the core under normal conditions but rapidly forces the control rods into the core by catapultic action in the event of an emergency. (AEC)
Thermal effect of diode-pumped solid state lasers based on composite crystals
NASA Astrophysics Data System (ADS)
Hao, Ming-ming; Lu, Guo-guang; Zhu, Hong-bo; Huang, Yun; En, Yun-fei
2013-12-01
Thermal effect of diode-pumped solid-state lasers (DPSSL) based on YAP/Tm:YAP composite crystal is studied by using of finite element method (FEM). It is found that the peak temperature in a composite rod decreases to less than 80% of that in a non-composite crystal. Thermal stress of composite rod is obviously reduced to less than 70% comparing with non-composite crystal. It is also demonstrated that length of thermal lens unchanged with increasing of un-doped crystal length, which means that beam quality of composite laser wouldn't be improved by non-composite crystal. Therefore, it is concluded that using composite crystal would benefit for the properties of temperature and heat stress while insignificance for beam quality of DPSSL.
NASA Astrophysics Data System (ADS)
Yasuoka, Takanori; Kato, Tomohiro; Kato, Katsumi; Okubo, Hitoshi
Electrode conditioning is very important technique for improvement of the insulation performance of vacuum circuit breakers (VCBs). This paper discusses the spark conditioning mechanism under non-uniform electric field focused on the pre-breakdown current. We quantitatively evaluated the spark conditioning effect by analyzing the pre-breakdown current based on Fowler-Nordheim equation. As a result, field enhancement factor β decreased with the increasing in breakdown voltage in the beginning of conditioning process, and finally β was saturated with the saturation of breakdown voltage. In addition, in case of non-uniform field, we found that β on high voltage rod electrode after conditioning varied according to the electric field strength on the rod electrode.
Multi-function magnetic jack control drive mechanism
Bollinger, L.R.; Crawford, D.C.
1983-10-06
A multi-function magnetic jack control drive mechanism for controlling a nuclear reactor is provided. The mechanism includes an elongate pressure housing in which a plurality of closely spaced drive rods are located. Each drive rod is connected to a rod which is insertable in the reactor core. An electromechanical stationary latch device is provided which is actuatable to hold each drive rod stationary with respect to the pressure housing. An electromechanical movable latch device is also provided for each one of the drive rods. Each movable latch device is provided with a base and is actuatable to hold a respective drive rod stationary with respect to the base. An electromechanical lift device is further provided for each base which is actuatable for moving a respective base longitudinally along the pressure housing. In this manner, one or more drive rods can be moved in the pressure housing by sequentially and repetitively operating the electromechanical devices. Preferably, each latch device includes a pair of opposed latches which grip teeth located on the respective drive rod. Two, three, or four drive rods can be located symmetrically about the longitudinal axis of the pressure housing.
Multi-function magnetic jack control drive mechanism
Bollinger, Lawrence R.; Crawford, Donald C.
1986-01-01
A multi-function magnetic jack control drive mechanism for controlling a nuclear reactor is provided. The mechanism includes an elongate pressure housing in which a plurality of closely spaced drive rods are located. Each drive rod is connected to a rod which is insertable in the reactor core. An electromechanical stationary latch device is provided which is actuatable to hold each drive rod stationary with respect to the pressure housing. An electromechanical movable latch device is also provided for each one of the drive rods. Each movable latch device is provided with a base and is actuatable to hold a respective drive rod stationary with respect to the base. An electromechanical lift device is further provided for each base which is actuatable for moving a respective base longitudinally along the pressure housing. In this manner, one or more drive rods can be moved in the pressure housing by sequentially and repetitively operating the electromechanical devices. Preferably, each latch device includes a pair of opposed latches which grip teeth located on the respective drive rod. Two, three, or four drive rods can be located symmetrically about the longitudinal axis of the pressure housing.
Slip-spring model of entangled rod-coil block copolymers
NASA Astrophysics Data System (ADS)
Wang, Muzhou; Likhtman, Alexei E.; Olsen, Bradley D.
2015-03-01
Understanding the dynamics of rod-coil block copolymers is important for optimal design of functional nanostructured materials for organic electronics and biomaterials. Recently, we proposed a reptation theory of entangled rod-coil block copolymers, predicting the relaxation mechanisms of activated reptation and arm retraction that slow rod-coil dynamics relative to coil and rod homopolymers, respectively. In this work, we introduce a coarse-grained slip-spring model of rod-coil block copolymers to further explore these mechanisms. First, parameters of the coarse-grained model are tuned to match previous molecular dynamics simulation results for coils, rods, and block copolymers. For activated reptation, rod-coil copolymers are shown to disfavor configurations where the rod occupies curved portions of the entanglement tube of randomly varying curvature created by the coil ends. The effect of these barriers on diffusion is quantitatively captured by considering one-dimensional motion along an entanglement tube with a rough free energy potential. Finally, we analyze the crossover between the two mechanisms. The resulting dynamics from both mechanisms acting in combination is faster than from each one individually.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This decision document, together with the Allied Chemical/Ironton Coke Record of Decision (ROD) dated December 28, 1990, the first Allied Chemical/Ironton Coke ROD Amendment dated July 31, 1995 (ROD Amendment No 1), and the second ROD Amendment dated September 4, 1997 (ROD Amendment No 2), presents the selected remedial action for the Allied Chemical/Ironton Coke site. The remedy selected in the 1990 ROD, 1995 ROD Amendment No. 1, and 1997 ROD Amendment No. 2 for the site is a final remedial action. Through ROD Amendment No. 3 the following components of the selected remedy are being modified: Replace in-situ bioremediationmore » of 457,000 cubic yards of soil in Lagoons 1--4 with hot spot excavation and wetland development; and Replace incineration of Lagoon 5 materials with recycling, treatment, and/or disposal of the K087 listed waste in an approved off-site hazardous waste facility and the use of the remaining material, excluding debris, as an alternative fuel.« less
Large Deformation of an Elastic Rod with Structural Anisotropy Subjected to Fluid Flow
NASA Astrophysics Data System (ADS)
Hassani, Masoud; Mureithi, Njuki; Gosselin, Frederick
2015-11-01
In the present work, we seek to understand the fundamental mechanisms of three-dimensional reconfiguration of plants by studying the large deformation of a flexible rod in fluid flow. Flexible rods made of Polyurethane foam and reinforced with Nylon fibers are tested in a wind tunnel. The rods have bending-torsion coupling which induces a torsional deformation during asymmetric bending. A mathematical model is also developed by coupling the Kirchhoff rod theory with a semi-empirical drag formulation. Different alignments of the material frame with respect to the flow direction and a range of structural properties are considered to study their effect on the deformation of the flexible rod and its drag scaling. Results show that twisting causes the flexible rods to reorient and bend with the minimum bending rigidity. It is also found that the drag scaling of the rod in the large deformation regime is not affected by torsion. Finally, using a proper set of dimensionless numbers, the state of a bending and twisting rod is characterized as a beam undergoing a pure bending deformation.
Wang, Muzhou; Timachova, Ksenia; Olsen, Bradley D.
2014-01-01
The diffusion of coil-rod-coil triblock copolymers in entangled coil homopolymers is experimentally measured and demonstrated to be significantly slower than rod or coil homopolymers of the same molecular weight. A model coil-rod-coil triblock was prepared by expressing rodlike alanine-rich α-helical polypeptides in E. coli and conjugating coillike poly(ethylene oxide) (PEO) to both ends to form coil-rod-coil triblock copolymers. Tracer diffusion through entangled PEO homopolymer melts was measured using forced Rayleigh scattering at various rod lengths, coil molecular weights, and coil homopolymer concentrations. For rod lengths, L, that are close to the entanglementh length, a, the ratio between triblock diffusivity and coil homopolymer diffusivity decreases monotonically and is only a function of L/a, in quantitative agreement with previous simulation results. For large rod lengths, diffusion follows an arm retraction scaling, which is also consistent with previous theoretical predictions. These experimental results support the key predictions of theory and simulation, suggesting that the mismatch in curvature between rod and coil entanglement tubes leads to the observed diffusional slowing. PMID:25484454
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peng, Kun, E-mail: kpeng@hnu.edu.cn; Hunan Province Key Laboratory for Spray Deposition Technology and Application, Hunan University, Changsha 410082; Jiang, Pan
2014-12-15
Graphical abstract: Layer-stack hexagonal cadmium oxide (CdO) micro-rods were prepared. - Highlights: • Novel hexagonal layer-stack structure CdO micro-rods were synthesized by a thermal evaporation method. • The pre-oxidation, vapor pressure and substrate nature play a key role on the formation of CdO rods. • The formation mechanism of CdO micro-rods was explained. - Abstract: Novel layer-stack hexagonal cadmium oxide (CdO) micro-rods were prepared by pre-oxidizing Cd granules and subsequent thermal oxidation under normal atmospheric pressure. X-ray diffraction (XRD) and scanning electron microscopy (SEM) were performed to characterize the phase structure and microstructure. The pre-oxidation process, vapor pressure and substratemore » nature were the key factors for the formation of CdO micro-rods. The diameter of micro-rod and surface rough increased with increasing of thermal evaporation temperature, the length of micro-rod increased with the increasing of evaporation time. The formation of hexagonal layer-stack structure was explained by a vapor–solid mechanism.« less
[Novel Device for Creating Multiple Artificial Chordae Loops in Mitral Valve Repair].
Shimamura, Yoshiei; Maisawa, Kazuma
2017-08-01
A novel device to create multiple artificial chordae loops for mitral repair is developed. The device consists of a circular metal base with a removable central rod on one end, which can easily be attached or removed by screwing into a hole located on the base, and 51 fixed rods placed radially around the central rod at distances of 10~60 mm from the central rod. A needle with CV-4 e-polytetrafluoroethylene suture is passed through a pledget, and the suture is looped from the central rod around the fixed rod located at the desired loop length. The needle is then passed back through the pledget. The suture is tied over the pledget, bringing it in contact with the central rod. When multiple loops of various lengths are required, different fixed rods located at distances corresponding to the required loop lengths are used. Following creation of the necessary loops, the central rod is unscrewed, and the loops are released from the device. Construction of artificial chordae with this device is quick, reliable, reproducible, and increases the technical possibilities for mitral valve repair.
Liang, Yuan-Chang; Xu, Nian-Cih; Wang, Chein-Chung; Wei, Da-Hua
2017-07-10
TiO₂-CdO composite rods were synthesized through a hydrothermal method and sputtering thin-film deposition. The hydrothermally derived TiO₂ rods exhibited a rectangular cross-sectional crystal feature with a smooth surface, and the as-synthesized CdO thin film exhibited a rounded granular surface feature. Structural analyses revealed that the CdO thin film sputtered onto the surfaces of the TiO₂ rods formed a discontinuous shell layer comprising many island-like CdO crystallites. The TiO₂-CdO composite rods were highly crystalline, and their surfaces were rugged. A comparison of the NO₂ gas-sensing properties of the CdO thin film, TiO₂ rods, and TiO₂-CdO composite rods revealed that the composite rods exhibited superior gas-sensing responses to NO₂ gas than did the CdO thin film and TiO 2 rods, which can be attributed to the microstructural differences and the formation of heterojunctions between the TiO₂ core and CdO crystallites.
Suppressing turbulence of self-propelling rods by strongly coupled passive particles.
Su, Yen-Shuo; Wang, Hao-Chen; I, Lin
2015-03-01
The strong turbulence suppression, mainly for large-scale modes, of two-dimensional self-propelling rods, by increasing the long-range coupling strength Γ of low-concentration passive particles, is numerically demonstrated. It is found that large-scale collective rod motion in forms of swirls or jets is mainly contributed from well-aligned dense patches, which can push small poorly aligned rod patches and uncoupled passive particles. The more efficient momentum transfer and dissipation through increasing passive particle coupling leads to the formation of a more ordered and slowed down network of passive particles, which competes with coherent dense active rod clusters. The frustration of active rod alignment ordering and coherent motion by the passive particle network, which interrupt the inverse cascading of forming large-scale swirls, is the key for suppressing collective rod motion with scales beyond the interpassive distance, even in the liquid phase of passive particles. The loosely packed active rods are weakly affected by increasing passive particle coupling due to the weak rod-particle interaction. They mainly contribute to the small-scale modes and high-speed motion.
1L Mark-IV Target Design Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koehler, Paul E.
This presentation includes General Design Considerations; Current (Mark-III) Lower Tier; Mark-III Upper Tier; Performance Metrics; General Improvements for Material Science; General Improvements for Nuclear Science; Improving FOM for Nuclear Science; General Design Considerations Summary; Design Optimization Studies; Expected Mark-IV Performance: Material Science; Expected Mark-IV Performance: Nuclear Science (Disk); Mark IV Enables Much Wider Range of Nuclear-Science FOM Gains than Mark III; Mark-IV Performance Summary; Rod or Disk? Center or Real FOV?; and Project Cost and Schedule.
ERIC Educational Resources Information Center
Dahlin, Karin I. E.
2013-01-01
Working Memory (WM) has a central role in learning. It is suggested to be malleable and is considered necessary for several aspects of mathematical functioning. This study investigated whether work with an interactive computerised working memory training programme at school could affect the mathematical performance of young children. Fifty-seven…
ERIC Educational Resources Information Center
Liu, Chia-Ju; Zandvliet, David B.; Hou, I.-Ling
2012-01-01
This study investigated perceptions of senior high school students towards the Taiwanese information technology (IT) classroom with the What Is Happening in this Class? (WIHIC) survey and explored the physical learning environment of the IT classroom using the Computerised Classroom Environment Inventory (CCEI). The participants included 2,869…
ERIC Educational Resources Information Center
Moothedath, Shana; Chaporkar, Prasanna; Belur, Madhu N.
2016-01-01
In recent years, the computerised adaptive test (CAT) has gained popularity over conventional exams in evaluating student capabilities with desired accuracy. However, the key limitation of CAT is that it requires a large pool of pre-calibrated questions. In the absence of such a pre-calibrated question bank, offline exams with uncalibrated…
ERIC Educational Resources Information Center
Read, Sue; Nte, Sol; Corcoran, Patsy; Stephens, Richard
2013-01-01
Background: Loss is a universal experience and death is perceived as the ultimate loss. The overarching aim of this research is to produce a qualitative, flexible, interactive, computerised tool to support the facilitation of emotional expressions around loss for people with intellectual disabilities. This paper explores the process of using…
Peer Assessment: Judging the Quality of Students' Work by Comments Rather than Marks
ERIC Educational Resources Information Center
Davies, Phil
2006-01-01
This paper reports the results of a study into the quality of peer feedback provided by students within a computerised peer-assessment environment. The study looks at the creation of a "feedback index" that represents the quality of an essay based upon the feedback provided during a peer-marking process and identifies a significant…
ERIC Educational Resources Information Center
Gürses, Nedim; Demiray, Emine
2009-01-01
In like manner as conventional education and teaching approaches distance education tends to model the same procedures. Indeed, formerly enriched on printed material served as a primary source. However, thanks to the developments in technology and evolution in education, computerised information has made inroads in distance education programmes.…
Experiencing Virtual Patients in Clinical Learning: A Phenomenological Study
ERIC Educational Resources Information Center
Edelbring, Samuel; Dastmalchi, Maryam; Hult, Hakan; Lundberg, Ingrid E.; Dahlgren, Lars Owe
2011-01-01
Computerised virtual patients (VPs) are increasingly being used in medical education. With more use of this technology, there is a need to increase the knowledge of students' experiences with VPs. The aim of the study was to elicit the nature of virtual patients in a clinical setting, taking the students' experience as a point of departure.…
ERIC Educational Resources Information Center
Lin, Yu-Shih; Chang, Yi-Chun; Liew, Keng-Hou; Chu, Chih-Ping
2016-01-01
Computerised testing and diagnostics are critical challenges within an e-learning environment, where the learners can assess their learning performance through tests. However, a test result based on only a single score is insufficient information to provide a full picture of learning performance. In addition, because test results implicitly…
ERIC Educational Resources Information Center
International Federation of Library Associations, The Hague (Netherlands).
The eight papers in this collection focus on library activities in various geographical regions, e.g., Asia, Oceania, Africa, Latin America, the Caribbean, and Western Australia: (1) "Future Approaches and Prospects of Computerised Information Network among the Countries of South Asian Association for Regional Cooperation (SAARC)" (Abdullah…
ERIC Educational Resources Information Center
Holt, Samantha; Yuill, Nicola
2014-01-01
Children with autism are said to lack other-awareness, which restricts their opportunities for peer collaboration. We assessed other-awareness in non-verbal children with autism and typically-developing preschoolers collaborating on a shared computerised picture-sorting task. The studies compared a novel interface, designed to support…
ERIC Educational Resources Information Center
Momoh, Mustapha
2010-01-01
This study examined the impediments to effective use of Information and Communication Technology (ICT) tools in Nigerian universities. Series of research conducted on the factors militating against computerisation indicated that, there were impediments to effective utilisation of ICT tools in most developing countries. In the light of this, the…
ERIC Educational Resources Information Center
Gurses, Nedim; Demiray, Emine
2009-01-01
In like manner as conventional education and teaching approaches distance education tends to model the same procedures. Indeed, formerly enriched on printed material served as a primary source. However, thanks to the developments in technology and evolution in education, computerised information has made inroads in distance education programmes.…
ERIC Educational Resources Information Center
Richards, Derek; Timulak, Ladislav
2013-01-01
Participants with symptoms of depression received either eight sessions of therapist-delivered email cognitive behaviour therapy (eCBT; n = 37), or eight sessions of computerised CBT self-administered treatment (cCBT; n = 43). At post-treatment participants completed a questionnaire to determine what they found satisfying about their online…
Van Berkel, Megan A; MacDermott, Jennifer; Dungan, Kathleen M; Cook, Charles H; Murphy, Claire V
2017-12-01
Although studies demonstrate techniques to limit hypoglycaemia in critically ill patients, there are limited data supporting methods to improve management of existing hypoglycaemia. Assess the impact and sustainability of a computerised, three tiered, nurse driven protocol for hypoglycaemia treatment. Retrospective pre and post protocol study. Neurosciences and surgical intensive care units at a tertiary academic medical centre. Patients with a hypoglycaemic episode were included during a pre-protocol or post-protocol implementation period. An additional six-month cohort was evaluated to assess sustainability. Fifty-four patients were included for evaluation (35 pre- and 19 post-protocol); 122 patients were included in the sustainability cohort. Hypoglycaemia treatment significantly improved in the post-protocol cohort (20% vs. 52.6%, p=0.014); with additional improvement to 79.5% in the sustainability cohort. Time to follow-up blood glucose was decreased after treatment from 122 [Q1-Q3: 46-242] minutes pre-protocol to 25 [Q1-Q3: 9-48] minutes post protocol (p<0.0001). This reduction was maintained in the sustainability cohort [median of 29min (Q1-Q3: 20-51)]. Implementation of a nurse-driven, three-tiered protocol for treatment of hypoglyacemia significantly improved treatment rates, as well as reduced time to recheck blood glucose measurement. These benefits were sustained during a six-month period after protocol implementation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Rod Has High Tensile Strength And Low Thermal Expansion
NASA Technical Reports Server (NTRS)
Smith, D. E.; Everton, R. L.; Howe, E.; O'Malley, M.
1996-01-01
Thoriated tungsten extension rod fabricated to replace stainless-steel extension rod attached to linear variable-differential transformer in gap-measuring gauge. Threads formed on end of rod by machining with special fixtures and carefully chosen combination of speeds and feeds.
Gettemy, D.J.; Barnes, N.P.; Griggs, J.E.
1981-08-11
The disclosure relates to a solid state laser rod holder comprising Invar, copper tubing, and epoxy joints. Materials and coefficients of expansion of the components of the holder combine with the rod to produce a joint which will give before the rod itself will. The rod may be lased at about 70 to 80/sup 0/K and returned from such a temperature to room temperature repeatedly without its or the holder's destruction.
NASA Astrophysics Data System (ADS)
Arnautov, A. K.; Terrasi, G. P.; Kulakov, V. L.; Portnov, G. G.
2014-01-01
The effectiveness of fastening of high-strength unidirectional CFRP/epoxy rods in potted anchors was investigated experimentally. The rods had splitted ends, in which duralumin wedges were glued. The experiments, performed for three types of contact between the composite rods and the potted material, showed that the most effective were full adhesion and adhesion-friction contacts, when the maximum load-carrying capacity of CFRP rods under tension could be reached. The full friction contact was ineffective because of the shear failure of CFRP rods inside the anchorage zone.
Paget, J.A.
1963-05-14
A structure for monitoring the structural continuity of a control rod foi a neutron reactor is presented. A electric conductor readily breakable under mechanical stress is fastened along the length of the control rod at a plurality of positions and forms a closed circuit with remote electrical components responsive to an open circuit. A portion of the conductor between the control rod and said components is helically wound to allow free and normally unrestricted movement of the segment of conductor secured to the control rod relative to the remote components. Any break in the circuit is indicative of control rod breakage. (AEC)
Neural net controlled tag gas sampling system for nuclear reactors
Gross, Kenneth C.; Laug, Matthew T.; Lambert, John D. B.; Herzog, James P.
1997-01-01
A method and system for providing a tag gas identifier to a nuclear fuel rod and analyze escaped tag gas to identify a particular failed nuclear fuel rod. The method and system include disposing a unique tag gas composition into a plenum of a nuclear fuel rod, monitoring gamma ray activity, analyzing gamma ray signals to assess whether a nuclear fuel rod has failed and is emitting tag gas, activating a tag gas sampling and analysis system upon sensing tag gas emission from a failed nuclear rod and evaluating the escaped tag gas to identify the particular failed nuclear fuel rod.
McKiernan, C J; Friedlander, M
1999-12-31
The retinal rod Na(+)/Ca(2+),K(+) exchanger (RodX) is a polytopic membrane protein found in photoreceptor outer segments where it is the principal extruder of Ca(2+) ions during light adaptation. We have examined the role of the N-terminal 65 amino acids in targeting, translocation, and integration of the RodX using an in vitro translation/translocation system. cDNAs encoding human RodX and bovine RodX through the first transmembrane domain were correctly targeted and integrated into microsomal membranes; deletion of the N-terminal 65 amino acids (aa) resulted in a translation product that was not targeted or integrated. Deletion of the first 65 aa had no effect on membrane targeting of full-length RodX, but the N-terminal hydrophilic domain no longer translocated. Chimeric constructs encoding the first 65 aa of bovine RodX fused to globin were translocated across microsomal membranes, demonstrating that the sequence could function heterologously. Studies of fresh bovine retinal extracts demonstrated that the first 65 aa are present in the native protein. These data demonstrate that the first 65 aa of RodX constitute an uncleaved signal sequence required for the efficient membrane targeting and proper membrane integration of RodX.
The biomechanical consequences of rod reduction on pedicle screws: should it be avoided?
Paik, Haines; Kang, Daniel G; Lehman, Ronald A; Gaume, Rachel E; Ambati, Divya V; Dmitriev, Anton E
2013-11-01
Rod contouring is frequently required to allow for appropriate alignment of pedicle screw-rod constructs. When residual mismatch is still present, a rod persuasion device is often used to achieve further rod reduction. Despite its popularity and widespread use, the biomechanical consequences of this technique have not been evaluated. To evaluate the biomechanical fixation strength of pedicle screws after attempted reduction of a rod-pedicle screw mismatch using a rod persuasion device. Fifteen 3-level, human cadaveric thoracic specimens were prepared and scanned for bone mineral density. Osteoporotic (n=6) and normal (n=9) specimens were instrumented with 5.0-mm-diameter pedicle screws; for each pair of comparison level tested, the bilateral screws were equal in length, and the screw length was determined by the thoracic level and size of the vertebra (35 to 45 mm). Titanium 5.5-mm rods were contoured and secured to the pedicle screws at the proximal and distal levels. For the middle segment, the rod on the right side was intentionally contoured to create a 5-mm residual gap between the inner bushing of the pedicle screw and the rod. A rod persuasion device was then used to engage the setscrew. The left side served as a control with perfect screw/rod alignment. After 30 minutes, constructs were disassembled and vertebrae individually potted. The implants were pulled in-line with the screw axis with peak pullout strength (POS) measured in Newton (N). For the proximal and distal segments, pedicle screws on the right side were taken out and reinserted through the same trajectory to simulate screw depth adjustment as an alternative to rod reduction. Pedicle screws reduced to the rod generated a 48% lower mean POS (495±379 N) relative to the controls (954±237 N) (p<.05) and significantly decreased work energy to failure (p<.05). Nearly half (n=7) of the pedicle screws had failed during the reduction attempt with visible pullout of the screw. After reduction, decreased POS was observed in both normal (p<.05) and osteoporotic (p<.05) bone. Back out and reinsertion of the screw resulted in no significant difference in mean POS, stiffness, and work energy to failure (p>.05). In circumstances where a rod is not fully seated within the pedicle screw, the use of a rod persuasion device decreases the overall POS and work energy to failure of the screw or results in outright failure. Further rod contouring or correction of pedicle screw depth of insertion may be warranted to allow for appropriate alignment of the longitudinal rods. Published by Elsevier Inc.
Ultrasonic longitudinal waves to monitor the integration of titanium rods with host bone
NASA Astrophysics Data System (ADS)
Wang, Wentao; Lynch, Jerome P.
2017-04-01
Osseointegrated prostheses which integrate the prosthesis directly to the limb bone are being developed for patients that are unable to wear traditional socket prostheses. While osseointegration of the prosthesis offers amputees improvement in their quality of life, there remains a need to better understand the integration process that occurs between the bone and the prosthesis. Quantification of the degree of integration is important to track the recuperation process of the amputee, guide physical therapy regimes, and to identify when the state of integration may change (due to damage to the bone). This study explores the development of an assessment strategy for quantitatively assessing the degree of integration between an osseointegrated prosthesis and host bone. Specifically, the strategy utilizes a titanium rod prosthesis as a waveguide with guided waves used to assess the degree of integration. By controlling waveforms launched by piezoelectric wafers bonded on the percutaneous tip of the prosthesis, body waves are introduced into the waveguide with wave reflections at the boneprosthesis interface recorded by the same array. Changes in wave energy are correlated to changes at the contact interface between the titanium rod and the bone material. Both simulation and experimental tests are presented in this paper. Experimental testing is performed using a high-density polyethylene (HDPE) host because the elastic modulus and density of HDPE are close to that of human and animal bone. Results indicate high sensitivity of the longitudinal wave energy to rod penetration depth and confinement stress issued by the host bone.
Heat transfer enhancement with mixing vane spacers using the field synergy principle
NASA Astrophysics Data System (ADS)
Yang, Lixin; Zhou, Mengjun; Tian, Zihao
2017-01-01
The single-phase heat transfer characteristics in a PWR fuel assembly are important. Many investigations attempt to obtain the heat transfer characteristics by studying the flow features in a 5 × 5 rod bundle with a spacer grid. The field synergy principle is used to discuss the mechanism of heat transfer enhancement using mixing vanes according to computational fluid dynamics results, including a spacer grid without mixing vanes, one with a split mixing vane, and one with a separate mixing vane. The results show that the field synergy principle is feasible to explain the mechanism of heat transfer enhancement in a fuel assembly. The enhancement in subchannels is more effective than on the rod's surface. If the pressure loss is ignored, the performance of the split mixing vane is superior to the separate mixing vane based on the enhanced heat transfer. Increasing the blending angle of the split mixing vane improves heat transfer enhancement, the maximum of which is 7.1%. Increasing the blending angle of the separate mixing vane did not significantly enhance heat transfer in the rod bundle, and even prevented heat transfer at a blending angle of 50°. This finding testifies to the feasibility of predicting heat transfer in a rod bundle with a spacer grid by field synergy, and upon comparison with analyzed flow features only, the field synergy method may provide more accurate guidance for optimizing the use of mixing vanes.
RPE65 gene therapy slows cone loss in Rpe65-deficient dogs.
Mowat, F M; Breuwer, A R; Bartoe, J T; Annear, M J; Zhang, Z; Smith, A J; Bainbridge, J W B; Petersen-Jones, S M; Ali, R R
2013-05-01
Recent clinical trials of retinal pigment epithelium gene (RPE65) supplementation therapy in Leber congenital amaurosis type 2 patients have demonstrated improvements in rod and cone function, but it may be some years before the effects of therapy on photoreceptor survival become apparent. The Rpe65-deficient dog is a very useful pre-clinical model in which to test efficacy of therapies, because the dog has a retina with a high degree of similarity to that of humans. In this study, we evaluated the effect of RPE65 gene therapy on photoreceptor survival in order to predict the potential benefit and limitations of therapy in patients. We examined the retinas of Rpe65-deficient dogs after RPE65 gene therapy to evaluate the preservation of rods and cone photoreceptor subtypes. We found that gene therapy preserves both rods and cones. While the moderate loss of rods in the Rpe65-deficient dog retina is slowed by gene therapy, S-cones are lost extensively and gene therapy can prevent that loss, although only within the treated area. Although LM-cones are not lost extensively, cone opsin mislocalization indicates that they are stressed, and this can be partially reversed by gene therapy. Our results suggest that gene therapy may be able to slow cone degeneration in patients if intervention is sufficiently early and also that it is probably important to treat the macula in order to preserve central function.
Hendricks, Charles D.
1988-01-01
A method is provided for producing commercially large quantities of high melting temperature solid or hollow spherical particles of a predetermined chemical composition and having a uniform and controlled size distribution. An end (18, 50, 90) of a solid or hollow rod (20, 48, 88) of the material is rendered molten by a laser beam (14, 44, 82). Because of this, there is no possibility of the molten rod material becoming contaminated with extraneous material. In various aspects of the invention, an electric field is applied to the molten rod end (18, 90), and/or the molten rod end (50, 90) is vibrated. In a further aspect of the invention, a high-frequency component is added to the electric field applied to the molten end of the rod (90). By controlling the internal pressure of the rod, the rate at which the rod is introduced into the laser beam, the environment of the process, the vibration amplitude and frequency of the molten rod end, the electric field intensity applied to the molten rod end, and the frequency and intensity of the component added to the electric field, the uniformity and size distribution of the solid or hollow spherical particles (122) produced by the inventive method is controlled. The polarity of the electric field applied to the molten rod end can be chosen to eliminate backstreaming electrons, which tend to produce run-away heating in the rod, from the process.
Eulerian Formulation of Spatially Constrained Elastic Rods
NASA Astrophysics Data System (ADS)
Huynen, Alexandre
Slender elastic rods are ubiquitous in nature and technology. For a vast majority of applications, the rod deflection is restricted by an external constraint and a significant part of the elastic body is in contact with a stiff constraining surface. The research work presented in this doctoral dissertation formulates a computational model for the solution of elastic rods constrained inside or around frictionless tube-like surfaces. The segmentation strategy adopted to cope with this complex class of problems consists in sequencing the global problem into, comparatively simpler, elementary problems either in continuous contact with the constraint or contact-free between their extremities. Within the conventional Lagrangian formulation of elastic rods, this approach is however associated with two major drawbacks. First, the boundary conditions specifying the locations of the rod centerline at both extremities of each elementary problem lead to the establishment of isoperimetric constraints, i.e., integral constraints on the unknown length of the rod. Second, the assessment of the unilateral contact condition requires, in principle, the comparison of two curves parametrized by distinct curvilinear coordinates, viz. the rod centerline and the constraint axis. Both conspire to burden the computations associated with the method. To streamline the solution along the elementary problems and rationalize the assessment of the unilateral contact condition, the rod governing equations are reformulated within the Eulerian framework of the constraint. The methodical exploration of both types of elementary problems leads to specific formulations of the rod governing equations that stress the profound connection between the mechanics of the rod and the geometry of the constraint surface. The proposed Eulerian reformulation, which restates the rod local equilibrium in terms of the curvilinear coordinate associated with the constraint axis, describes the rod deformed configuration by means of either its relative position with respect to the constraint axis (contact-free segments) or its angular position on the constraint surface (continuous contacts.) This formulation circumvents both drawbacks that afflict the conventional Lagrangian approach associated with the segmentation strategy. As the a priori unknown domain, viz. the rod length, is substituted for the known constraint axis, the free boundary problem and the associated isoperimetric constraints are converted into a classical two-point boundary value problem. Additionally, the description of the rod deflection by means of its eccentricity with respect to the constraint axis trivializes the assessment of the unilateral contact condition. Along continuous contacts, this formulation expresses the strain variables, measuring the rod change of shape, in terms of the geometric invariants of the constraint surface, and emphasizes the influence of the constraint local geometry on the reaction pressure. Formalizing the segmentation strategy, a computational model that exploits the Eulerian formulation of the rod governing equations is devised. To solve the quasi-static deflection of elastic rods constrained inside or around a tube-like surface, this computational model identifies the number of contacts, their nature (either discrete or continuous), and the rod configuration at the connections that satisfies the unilateral contact condition and preserves the rod integrity along the sequence of elementary problems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferrandis, J.Y.; Leveque, G.; Rosenkrantz, E.
2015-07-01
First of all, we will present the main principle of the method. A piezoelectric transducer, driven by a pulse generator, generates the acoustic waves in a cavity that may be the fuel rod or a chamber connected to an instrumented rod. The composition determination consists in measuring the time of flight of the acoustic signal emitted. The pressure can be estimated by a calibration process, above the measurement of the amplitude of the signal. Two projects will then be detailed. The first project consists in the development of advanced instrumentation for in-pile experiments in Material Testing Reactor. It constitutes amore » main goal for the improvement of the nuclear fuel behavior knowledge. This acoustic method was tested with success during a first experiment called REMORA 3, and the results were used to differentiate helium and fission gas release kinetics under transient operating conditions. This experiment was lead at OSIRIS reactor (CEA Saclay, France). As a first step of the development program, we performed in-pile tests on the most sensitive component, i.e., the piezoelectric transducer. For this purpose, the active part of this sensor has been qualified on gamma and neutron radiations and at high temperature. Various industrial piezo-ceramics were exposed to a high activity Cobalt source for few days. The cumulated dose was ranged from 50 kGy up to 2 MGy. Next, these devices were placed inside a Material Test Reactor to investigate their reliability towards neutron fluence. The final fluence after 150 days of irradiation was up to 1.6.10{sup 21}n/cm{sup 2} (for thermal neutron). Irreversible variations have been measured. Next, a specific sensor has been implemented on an instrumented fuel rod and tested in the frame of a REMORA 3 Irradiation test. It was the first experiment under high mixed, temperature neutron and gamma flux. A first irradiation phase took place in March 2010 in the OSIRIS reactor and in November 2010 for the second step of the irradiation. The instrumented fuel rod incorporating the ultrasonic gas composition sensor was finally irradiated during 2 weeks in nominal conditions. Neutronics calculation will be performed in order to calculate the thermal and fast neutron fluence and the gamma dose absorbed by acoustic sensor. A first evaluation gives a thermal fluence about 4,5.10{sup 19} n/cm{sup 2}, a fast neutrons fluence about 4,5.1018 n/cm{sup 2} and a total gamma dose up to 0,25 MGy The maximal temperature during the irradiation test was about 150 C. Although the ultrasonic sensor appears to be damaged, the optimization of the electrical attack parameters and the development of a new signal processing maintain the measurement feasibility up the end of the irradiation campaign. It was the first time that the composition of fission gas has been monitored all along an irradiation experiment in a MTR, giving access to the gas release kinetics. New researches involve thick film transducers produced by screen-printing process in order to propose piezoelectric structures for harsh temperature and irradiation measurements. The second project consists in the development of a non-destructive device that can be directly applied on a LWR fuel rod. The problem to be solved relates to the measurement of the fission gas pressure and composition in a fuel rod using a non-destructive method. Fuel rod internal pressure is one of the safety criteria applied in nuclear power analyses. This criterion must be verified in order to avoid any fuel-cladding gap reopening risk and therefore any local clad ballooning. Apart from the safety implications, this parameter is also a fuel behaviour indicator and reflects the overall fuel performance in operation, but also during shipping and long-term storage. Rod internal pressure is one criterion amongst others, like cladding corrosion, against which the acceptable fuel burn-up limit is set. A sensor has been achieved in 2007. A full-scale hot cell test of the internal gas pressure and composition measurement by an acoustic sensor was conducted successfully between 2008 and 2010 on 5 high burn-up MOX fuel rods and 2 very high burn-up UO{sub 2} fuel rods in LECA Facility at Cadarache Centre. An improvement of this sensor has been proposed, allowing us to divide by two the uncertainty on the pressure measurement. In the case of hot-cell measurements, viscous liquid can be used to couple the sensor with the rod. For gas content with a pressure exceeding 15 bars and a 10% Xe/Kr ratio, such coupling may reduce relative acoustic method accuracy by ±7% for pressure measurement result and ±0.25 % for the assessment of gas composition. These results make it possible to demonstrate the feasibility of the technique on LWR fuel rods. The transducer and the associated methodology are now operational for non-destructive measurements in hot lab facilities and allow characterising the fission gas without puncturing the fuel rods. Up to now, any other non-destructive method can be proposed. A next step will be the development of an industrial application in a fuel storage pool in order to perform a large number of measurements on a fuel assembly in nuclear plants.« less
35. INTERIOR VIEW, SAME AS ABOVE WITH THE FEEDER ROD ...
35. INTERIOR VIEW, SAME AS ABOVE WITH THE FEEDER ROD INSERTED INTO THE MACHINE; NOTE THE WOOD FEEDER ROD AND FEEDER ROD REST ON THE BACK OF THE STOOL - LaBelle Iron Works, Thirtieth & Wood Streets, Wheeling, Ohio County, WV
Grid-to-rod flow-induced impact study for PWR fuel in reactor
Jiang, Hao; Qu, Jun; Lu, Roger Y.; ...
2016-06-10
The source for grid-to-rod fretting in a pressurized water nuclear reactor (PWR) is the dynamic contact impact from hydraulic flow-induced fuel assembly vibration. In order to support grid-to-rod fretting wear mitigation research, finite element analysis (FEA) was used to evaluate the hydraulic flow-induced impact intensity between the fuel rods and the spacer grids. Three-dimensional FEA models, with detailed geometries of the dimple and spring of the actual spacer grids along with fuel rods, were developed for flow impact simulation. The grid-to-rod dynamic impact simulation provided insights of the contact phenomena at grid-rod interface. Finally, it is an essential and effectivemore » way to evaluate contact forces and provide guidance for simulative bench fretting-impact tests.« less