Sample records for improvement protocol tip

  1. Substance Abuse Treatment: Group Therapy. Treatment Improvement Protocol (TIP) Series 41

    ERIC Educational Resources Information Center

    Gilbert, Jonathan Max; Hills, Susan; Rife, Mary Lou

    2005-01-01

    This Treatment Improvement Protocol (TIP) presents an overview of the role and efficacy of group therapy in substance abuse treatment. TIPs are best-practice guidelines for the treatment of substance use disorders that make the latest research in substance abuse treatment available to counselors and educators. The content was generated by a panel…

  2. Substance Abuse Treatment for Persons With Co-Occurring Disorders. Treatment Improvement Protocol (TIP) Series 42

    ERIC Educational Resources Information Center

    Sacks, Stanley; Ries, Richard K.

    2005-01-01

    This Treatment Improvement Protocol (TIP) provides guidelines for counselors and others working in the field of co-occurring substance use and mental disorders. TIPs are best-practice guidelines for the treatment of substance use disorders that make the latest research in substance abuse treatment available to counselors and educators. The content…

  3. Substance Abuse Treatment For Adults in the Criminal Justice System. Treatment Improvement Protocol (TIP) Series 44

    ERIC Educational Resources Information Center

    Bartlett, Catalina; Dinsmore, Janet; Gilbert, J. Max; Kornblum, Annette; Latham, Joyce; Oliff, Helen; Paisner, Susan; Sutton, David

    2005-01-01

    This Treatment Improvement Protocol (TIP) provides guidelines for counselors and criminal justice personnel who treat offenders with substance use disorders. TIPs are best-practice guidelines that make the latest research in substance abuse treatment available to counselors and educators. The content was generated by a panel of experts in the…

  4. Substance Abuse Treatment And Family Therapy. A Treatment Improvement Protocol (TIP) Series 39

    ERIC Educational Resources Information Center

    Gilbert, Jonathan Max; Oliff, Helen; Sutton, David; Bartlett, Catalina; Henderson, Randi

    2004-01-01

    This Treatment Improvement Protocol (TIP) addresses substance abuse treatment in the context of family therapy. TIPs are best-practice guidelines for the treatment of substance use disorders that make the latest research in substance abuse treatment available to counselors and educators. The content was generated by a panel of experts in the…

  5. Addressing Viral Hepatitis in People with Substance Use Disorders. Treatment Improvement Protocol (TIP) Series 53

    ERIC Educational Resources Information Center

    Substance Abuse and Mental Health Services Administration, 2011

    2011-01-01

    Treatment Improvement Protocols (TIPs) are developed by the Center for Substance Abuse Treatment (CSAT), part of the Substance Abuse and Mental Health Services Administration (SAMHSA) within the U.S. Department of Health and Human Services (HHS). Each TIP involves the development of topic-specific best-practice guidelines for the prevention and…

  6. Clinical Guidelines for the Use of Buprenorphine in the Treatment of Opioid Addiction. Treatment Improvement Protocol (TIP) Series 40

    ERIC Educational Resources Information Center

    Boone, Margaret; Brown, Nancy J.; Moon, Mary A.; Schuman, Deborah J.; Thomas, Josephine; Wright, Denise L.

    2004-01-01

    This Treatment Improvement Protocol (TIP) addresses the clinical use of buprenorphine in the treatment of opioid addiction. TIPs are best-practice guidelines for the treatment of substance use disorders that make the latest research in substance abuse treatment available to counselors and educators. The content was generated by a panel of experts…

  7. A Qualitative Study of the Treatment Improvement Protocols (TIPs): An Assessment of the Use of TIPs by Individuals Affiliated with the Addiction Technology Transfer Centers (ATTCs).

    ERIC Educational Resources Information Center

    Hayashi, Susan W.; Suzuki, Marcia; Hubbard, Susan M.; Huang, Judy Y.; Cobb, Anita M.

    2003-01-01

    Evaluated the Addiction Technology Transfer Centers (ATTCs) of the Center for Substance Abuse Treatment (CSAT) as a means of diffusion of innovations, focusing on use of the Treatment Improvement Protocols (TIPs). Qualitative studies at 6 ATTCs that included 57 interviews show that the CSAT is at the forefront of providing resources to the…

  8. Substance Abuse Treatment for Persons with Co-Occurring Disorders. Treatment Improvement Protocol (TIP) Series 42

    ERIC Educational Resources Information Center

    Substance Abuse and Mental Health Services Administration, 2005

    2005-01-01

    Treatment Improvement Protocols (TIPs), developed by the Center for Substance Abuse Treatment (CSAT), part of the Substance Abuse and Mental Health Services Administration (SAMHSA) within the U.S. Department of Health and Human Services (DHHS), are best-practice guidelines for the treatment of substance use disorders. CSAT draws on the experience…

  9. TIPS Evaluation Project Retrospective Study: Wave 1 and 2.

    ERIC Educational Resources Information Center

    Hubbard, Susan M.; Mulvey, Kevin P.

    2003-01-01

    Measured substance abuse treatment professionals' knowledge, attitudes, and practices regarding the Treatment Improvement Protocol (TIP) series and the 28 TIPs. Results for 3,267 respondents in wave 1 and 1,028 in wave 2 indicate that almost half of all professionals were aware of the TIPs. Attitudes toward TIPs were positive, but professionals…

  10. Faces of Change: Do I Have a Problem with Alcohol or Drugs?

    MedlinePlus

    ... in Substance Abuse Treatment , #35 in SAMHSA’s Treatment Improvement Protocol (TIP) Series. The TIP series and its affiliated products may be ordered from SAMHSA’s Publications Ordering Web ...

  11. Use of Diffusion of Innovations Theory To Drive a Federal Agency's Program Evaluation.

    ERIC Educational Resources Information Center

    Hubbard, Susan M.; Hayashi, Susan W.

    2003-01-01

    Provides the conceptual framework for the Treatment Improvement Protocols (TIPs) evaluation project, using the diffusion of innovations theory as the theoretical foundation to understand and assess the development of TIPs. Summarizes principles of diffusion theory, and discusses how the model was used to structure the TIPs studies. (SLD)

  12. Medication-Assisted Treatment For Opioid Addiction in Opioid Treatment Programs. Treatment Improvement Protocol (TIP) Series 43

    ERIC Educational Resources Information Center

    Tinkler, Emily; Vallejos Bartlett, Catalina; Brooks, Margaret; Gilbert, Johnatnan Max; Henderson, Randi; Shuman, Deborah, J.

    2005-01-01

    TIP 43 provides best-practice guidelines for medication-assisted treatment of opioid addiction in opioid treatment programs (OTPs). The primary intended audience for this volume is substance abuse treatment providers and administrators who work in OTPs. Recommendations in the TIP are based on both an analysis of current research and determinations…

  13. The TIPS Evaluation Project: A Theory-Driven Approach to Dissemination Research.

    ERIC Educational Resources Information Center

    Mulvey, Kevin P.; Hayashi, Susan W.; Hubbard, Susan M.; Kopstien, Andrea; Huang, Judy Y.

    2003-01-01

    Introduces the special section that focuses on four major studies under the treatment improvement protocols (TIPs) evaluation project. Provides an overview of each article, and addresses the value of using a theory-driven approach to dissemination research. (SLD)

  14. Substance Abuse Treatment and Domestic Violence. Treatment Improvement Protocol (TIP) Series 25.

    ERIC Educational Resources Information Center

    Cook, Paddy; Gartner, Constance Grant; Markl, Lise; Henderson, Randi; Brooks, Margaret K.; Wesson, Donald; Dogoloff, Mary Lou; Vitzthum, Virginia; Hayes, Elizabeth

    The major goal of this TIP, on the best practice guidelines to improve the treatment of substance abuse, is to provide clinicians, educators, and paraprofessionals with the latest findings concerning domestic violence. The information is intended to educate providers about the needs and behaviors of batterers and survivors, and how to tailor…

  15. Treatment for Stimulant Use Disorders. Treatment Improvement Protocol (TIP) Series 33.

    ERIC Educational Resources Information Center

    Substance Abuse and Mental Health Services Administration (DHHS/PHS), Rockville, MD. Center for Substance Abuse Treatment.

    This TIP on the best practice guidelines for treatment of substance abuse provides basic knowledge for practitioners, educators, and paraprofessionals about the nature and treatment of stimulant use disorders. More specifically, it reviews what is currently known about treating the medical, psychiatric, and substance abuse/dependence problems…

  16. Substance Abuse Treatment for Persons with HIV/AIDS. Treatment Improvement Protocol (TIP) Series 37.

    ERIC Educational Resources Information Center

    CDM Group, Inc.

    The role of substance abuse in the transmission of HIV and AIDS is clear, and the current trend in the pandemic shows that a disproportionate number of minorities in inner cities are affected or are at risk for contracting HIV. The recommendations and guidelines in this TIP support the creation of a comprehensive, integrated system of care for…

  17. Use of protoplast, cell, and shoot tip culture in an elm germ plasm improvement program

    Treesearch

    R. Daniel Lineberger; M.B. Sticklen; P.M. Pijut; Mark A. Kroggel; C.V.M. Fink; S.C. Domir

    1990-01-01

    An elm germplasm improvement program was established using three distinct approaches: (1) development of protoplast regeneration protocols with the goal of attempting somatic hybridization between Ulmus americana and disease resistant hybrids; (2) evaluation of the extent of somaclonal variation in plants regenerated from protoplasts; and (3)...

  18. Evaluation of a suicide prevention training curriculum for substance abuse treatment providers based on Treatment Improvement Protocol Number 50 (TIP 50)

    PubMed Central

    Conner, Kenneth R.; Wood, Jane; Pisani, Anthony R.; Kemp, Janet

    2013-01-01

    Substance use disorders (SUD) confer risk for suicide yet there are no empirically supported suicide prevention training curricula tailored to SUD treatment providers. We assessed the efficacy of a 2-hour training that featured a suicide prevention training video produced by the Department of Veterans Affairs (VA). The video was based on Treatment Improvement Protocol Number 50, TIP 50, a practical manual to manage suicide risk produced by the Substance Abuse and Mental Health Services Administration (SAMHSA). The training was provided in small groups to 273 SUD treatment providers in 18 states. Results were evaluated using self-report assessments obtained at pre-test, post-test, and 2-month follow-up. Statistically significant changes (p<.001) within subjects were obtained on self-efficacy, knowledge, and frequency of suicide prevention practice behaviors. The positive results together with the brevity of the training and its ease of implementation indicate high potential for widespread adoption and the importance of further study. PMID:22417671

  19. Pilot Testing Fall TIPS (Tailoring Interventions for Patient Safety): a Patient-Centered Fall Prevention Toolkit.

    PubMed

    Dykes, Patricia C; Duckworth, Megan; Cunningham, Stephanie; Dubois, Sasha; Driscoll, Melissa; Feliciano, Zinnia; Ferrazzi, Michael; Fevrin, Farah E; Lyons, Stephanie; Lindros, Mary Ellen; Monahan, Allison; Paley, Matthew M; Jean-Pierre, Saby; Scanlan, Maureen

    2017-08-01

    Patient falls during an acute hospitalization cause injury, reduced mobility, and increased costs. The laminated paper Fall TIPS Toolkit (Fall TIPS) provides clinical decision support at the bedside by linking each patient's fall risk assessment with evidence-based interventions. Strategies were needed to integrate this evidence into clinical practice. The Institute for Healthcare Improvement's Framework for Spread is the conceptual model for pilot implementation of Fall TIPS at Brigham and Women's Hospital (BWH; Boston) and Montefiore Medical Center (MMC; Bronx, New York). The key to translating the evidence into practice was engaging stakeholders by leveraging existing shared governance structures, identifying unit champions, holding training sessions for all staff, and implementing auditing to assess and provide feedback on protocol adherence and patient outcomes. BWH unit compliance with using Fall TIPS averaged 82%, the mean fall rate decreased from 3.28 to 2.80 falls per 1,000 patient-days from January through June 2015 versus 2016, and the mean fall with injury rate for these periods decreased from 1.00 to 0.54 per 1,000 patient-days. At MMC, compliance averaged 91%, but the mean fall rate increased marginally from 3.04 to 3.10, while the mean fall with injury rate decreased from 0.47 to 0.31 per 1,000 patient-days. Patient knowledge survey results show improvement in knowledge of the risks for falls and the ways to prevent falls. Engaging hospital and clinical leadership is critical in translating evidence-based care into clinical practice. Barriers to adoption of the protocol have been addressed and detailed to provide guidance for spread to other institutions. Copyright © 2017 The Joint Commission. Published by Elsevier Inc. All rights reserved.

  20. Vitamins C and E improve regrowth and reduce lipid peroxidation of blackberry shoot tips following cryopreservation.

    PubMed

    Uchendu, Esther E; Leonard, Scott W; Traber, Maret G; Reed, Barbara M

    2010-01-01

    Oxidative processes involved in cryopreservation protocols may be responsible for the reduced viability of tissues after liquid nitrogen exposure. Antioxidants that counteract these reactions should improve recovery. This study focused on oxidative lipid injury and the effects of exogenous vitamin E (tocopherol, Vit E) and vitamin C (ascorbic acid, Vit C) treatments on regrowth at four critical steps of the plant vitrification solution number 2 (PVS2) vitrification cryopreservation technique; pretreatment, loading, rinsing, and regrowth. Initial experiments showed that Vit E at 11-15 mM significantly increased regrowth (P < 0.001) when added at any of the four steps. There was significantly more malondialdehyde (MDA), a lipid peroxidation product, at each of the steps than in fresh untreated shoot tips. Vit E uptake was assayed at each step and showed significantly more alpha- and gamma-tocopherols in treated shoots than those without Vit E. Vit E added at each step significantly reduced MDA formation and improved shoot regrowth. Vit C (0.14-0.58 mM) also significantly improved regrowth of shoot tips at each step compared to the controls. Regrowth medium with high iron concentrations and Vit C decreased recovery. However, in iron-free medium, Vit C significantly improved recovery. Treatments with Vit E (11 mM) and Vit C (0.14 mM) combined were not significantly better than Vit C alone. We recommend adding Vit C (0.28 mM) to the pretreatment medium, the loading solution or the rinse solution in the PVS2 vitrification protocol. This is the first report of the application of vitamins for improving cryopreservation of plant tissues by minimizing oxidative damage.

  1. Reference system for scanning probe tip fingerprinting

    NASA Astrophysics Data System (ADS)

    Turansky, Robert; Bamidele, Joseph; Sugawara, Yasuhiro; Kantorovitch, Lev; Stich, Ivan

    2012-02-01

    Knowledge of the chemical structure of the tip asperity in Non-Contact Atomic Force Microscopy (NC-AFM) is crucial as controlled manipulation of atoms and/or molecules on surfaces can only be performed if this information is available. However, a simple and robust protocol for ensuring a specific tip termination has not yet been developed. We propose a procedure for chemical tip finger printing and an example of a reference system, the oxygen-terminated Cu(110) surface, that enables one to ensure a specific tip termination with Si, Cu, or O atoms. To follow this up and unambiguously determine tip types, we performed a theoretical DFT study of the line scans with the tip models in question and found that the tip characterization made based on experimental results (Cu/O-terminated tip imaging Cu/O atoms) is in fact incorrect and the opposite is true (Cu/O-terminated tip imaging O/Cu atoms). This protocol allows the tip asperity's chemical structure to be verified and established both before as well as at any stage of the manipulation experiment when numerous tip changes may take place.

  2. Automated processing of forensic casework samples using robotic workstations equipped with nondisposable tips: contamination prevention.

    PubMed

    Frégeau, Chantal J; Lett, C Marc; Elliott, Jim; Yensen, Craig; Fourney, Ron M

    2008-05-01

    An automated process has been developed for the analysis of forensic casework samples using TECAN Genesis RSP 150/8 or Freedom EVO liquid handling workstations equipped exclusively with nondisposable tips. Robot tip cleaning routines have been incorporated strategically within the DNA extraction process as well as at the end of each session. Alternative options were examined for cleaning the tips and different strategies were employed to verify cross-contamination. A 2% sodium hypochlorite wash (1/5th dilution of the 10.8% commercial bleach stock) proved to be the best overall approach for preventing cross-contamination of samples processed using our automated protocol. The bleach wash steps do not adversely impact the short tandem repeat (STR) profiles developed from DNA extracted robotically and allow for major cost savings through the implementation of fixed tips. We have demonstrated that robotic workstations equipped with fixed pipette tips can be used with confidence with properly designed tip washing routines to process casework samples using an adapted magnetic bead extraction protocol.

  3. Managing Chronic Pain in Adults with or in Recovery from Substance Use Disorders. Treatment Improvement Protocol (TIP) Series 54

    ERIC Educational Resources Information Center

    Substance Abuse and Mental Health Services Administration, 2012

    2012-01-01

    Chronic noncancer pain (CNCP) is common in the general population as well as in people who have a substance use disorder (SUD) (Exhibit 1-1). Chronic pain is not harmless; it has physiological, social, and psychological dimensions that can seriously harm health, functioning, and well-being. As a multidimensional condition with both objective and…

  4. Implementation of a Transfer Intervention Procedure (TIP) to improve handovers from hospital to home: interrupted time series analysis.

    PubMed

    van Seben, Rosanne; Geerlings, Suzanne E; Verhaegh, Kim J M; Hilders, Carina G J M; Buurman, Bianca M

    2016-09-07

    Accurate and timely patient handovers from hospital to other health care settings are essential in order to provide high quality of care and to ensure patient safety. We aim to investigate the effect of a comprehensive discharge bundle, the Transfer Intervention Procedure (TIP), on the time between discharge and the time when the medical, medication and nursing handovers are sent to the next health care provider. Our goal is to reduce this time to 24 h after hospital discharge. Secondary outcomes are length of hospital stay and unplanned readmission within 30 days rates. The current study is set to implement the TIP, a structured discharge process for all patients admitted to the hospital, with the purpose to provide a safe, reliable and accurate discharge process. Eight hospitals in the Netherlands will implement the TIP on one internal medicine and one surgical ward. An interrupted time series (ITS) analysis, with pre-defined pre and post intervention periods, will be conducted. Patients over the age of 18 admitted for more than 48 h to the participating wards are eligible for inclusion. At least 1000 patients will be included in both the pre-implementation and post-implementation group. The primary outcome is the number of medical, medication and nursing handovers being sent within 24 h after discharge. Secondary outcomes are length of hospital stay and unplanned readmission within 30 days. With regard to potential confounders, data will be collected on patient's characteristics and information regarding the hospitalization. We will use segmented regression methods for analyzing the data, which allows assessing how much TIP changed the outcomes of interest immediately and over time. This study protocol describes the implementation of TIP, which provides the foundation for a safe, reliable and accurate discharge process. If effective, nationwide implementation of the discharge bundle may result from this study protocol. Dutch Trial Registry: NTR5951.

  5. Calibrated work function mapping by Kelvin probe force microscopy

    NASA Astrophysics Data System (ADS)

    Fernández Garrillo, Pablo A.; Grévin, Benjamin; Chevalier, Nicolas; Borowik, Łukasz

    2018-04-01

    We propose and demonstrate the implementation of an alternative work function tip calibration procedure for Kelvin probe force microscopy under ultrahigh vacuum, using monocrystalline metallic materials with known crystallographic orientation as reference samples, instead of the often used highly oriented pyrolytic graphite calibration sample. The implementation of this protocol allows the acquisition of absolute and reproducible work function values, with an improved uncertainty with respect to unprepared highly oriented pyrolytic graphite-based protocols. The developed protocol allows the local investigation of absolute work function values over nanostructured samples and can be implemented in electronic structures and devices characterization as demonstrated over a nanostructured semiconductor sample presenting Al0.7Ga0.3As and GaAs layers with variable thickness. Additionally, using our protocol we find that the work function of annealed highly oriented pyrolytic graphite is equal to 4.6 ± 0.03 eV.

  6. Contrast-Enhanced Magnetic Resonance Cholangiography: Practical Tips and Clinical Indications for Biliary Disease Management.

    PubMed

    Palmucci, Stefano; Roccasalva, Federica; Piccoli, Marina; Fuccio Sanzà, Giovanni; Foti, Pietro Valerio; Ragozzino, Alfonso; Milone, Pietro; Ettorre, Giovanni Carlo

    2017-01-01

    Since its introduction, MRCP has been improved over the years due to the introduction of several technical advances and innovations. It consists of a noninvasive method for biliary tree representation, based on heavily T2-weighted images. Conventionally, its protocol includes two-dimensional single-shot fast spin-echo images, acquired with thin sections or with multiple thick slabs. In recent years, three-dimensional T2-weighted fast-recovery fast spin-echo images have been added to the conventional protocol, increasing the possibility of biliary anatomy demonstration and leading to a significant benefit over conventional 2D imaging. A significant innovation has been reached with the introduction of hepatobiliary contrasts, represented by gadoxetic acid and gadobenate dimeglumine: they are excreted into the bile canaliculi, allowing the opacification of the biliary tree. Recently, 3D interpolated T1-weighted spoiled gradient echo images have been proposed for the evaluation of the biliary tree, obtaining images after hepatobiliary contrast agent administration. Thus, the acquisition of these excretory phases improves the diagnostic capability of conventional MRCP-based on T2 acquisitions. In this paper, technical features of contrast-enhanced magnetic resonance cholangiography are briefly discussed; main diagnostic tips of hepatobiliary phase are showed, emphasizing the benefit of enhanced cholangiography in comparison with conventional MRCP.

  7. A simplified field protocol for genetic sampling of birds using buccal swabs

    USGS Publications Warehouse

    Vilstrup, Julia T.; Mullins, Thomas D.; Miller, Mark P.; McDearman, Will; Walters, Jeffrey R.; Haig, Susan M.

    2018-01-01

    DNA sampling is an essential prerequisite for conducting population genetic studies. For many years, blood sampling has been the preferred method for obtaining DNA in birds because of their nucleated red blood cells. Nonetheless, use of buccal swabs has been gaining favor because they are less invasive yet still yield adequate amounts of DNA for amplifying mitochondrial and nuclear markers; however, buccal swab protocols often include steps (e.g., extended air-drying and storage under frozen conditions) not easily adapted to field settings. Furthermore, commercial extraction kits and swabs for buccal sampling can be expensive for large population studies. We therefore developed an efficient, cost-effective, and field-friendly protocol for sampling wild birds after comparing DNA yield among 3 inexpensive buccal swab types (2 with foam tips and 1 with a cotton tip). Extraction and amplification success was high (100% and 97.2% respectively) using inexpensive generic swabs. We found foam-tipped swabs provided higher DNA yields than cotton-tipped swabs. We further determined that omitting a drying step and storing swabs in Longmire buffer increased efficiency in the field while still yielding sufficient amounts of DNA for detailed population genetic studies using mitochondrial and nuclear markers. This new field protocol allows time- and cost-effective DNA sampling of juveniles or small-bodied birds for which drawing blood may cause excessive stress to birds and technicians alike.

  8. Efficacy of four different irrigation techniques combined with 60 °C 3% sodium hypochlorite and 17% EDTA in smear layer removal.

    PubMed

    Guo, Xiangjun; Miao, Hui; Li, Lei; Zhang, Shasha; Zhou, Dongyan; Lu, Yan; Wu, Ligeng

    2014-09-08

    Efforts to improve the efficacy of smear layer removal by applying irrigant activation at the final irrigation or by elevating the temperature of the irrigant have been reported. However, the combination of such activation protocols with 60 °C 3% sodium hypochlorite (NaOCl) has seldom been mentioned. The aim of this study was to compare the efficacy in smear layer removal of four different irrigation techniques combined with 60 °C 3% NaOCl and 17% EDTA. Fifty single-rooted teeth were randomly divided into five groups (n = 10) according to the irrigant agitation protocols used during chemomechanical preparation(Dentsply Maillefer, Ballaigues, Switzerland): a side-vented needle group, a ultrasonic irrigation (UI) group, a NaviTip FX group, an EndoActivator group, and a control group (no agitation). After each instrumentation, the root canals were irrigated with 1 mL of 3% NaOCl at 60 °C for 1 minute, and after the whole instrumentation, the root canals were rinsed with 1 mL of 17% EDTA for 1 minute. Both NaOCl and EDTA were activated with one of the five irrigation protocols. The efficacy of smear layer removal was scored at the apical, middle and coronal thirds. The Data were statistically analyzed using SAS version 9.2 for Windows (rank sum test for a randomised block design and ANOVA). No significant differences among the NaviTip FX group, EndoActivator group and control groups, and each of these groups showed a lower score than that of UI group (P < 0.05). Within each group, all three thirds were ranked in the following order: coronal > middle > apical (P < 0.05). In the coronal third, the NaviTip FX group was better than UI group. In the middle and apical third, the differences were not significant among any of the groups. Even without any activation, the combination of 60 °C 3% NaOCl and 17% EDTA could remove the smear layer effectively, similar to NaviTip FX or EndoActivator, and these three protocols were more effective than UI. However, regardless of different types of irrigation technique applied, complete removal of the smear layer was not achieved, particularly in the apical third.

  9. Identifying passivated dynamic force microscopy tips on H:Si(100)

    NASA Astrophysics Data System (ADS)

    Sharp, Peter; Jarvis, Sam; Woolley, Richard; Sweetman, Adam; Kantorovich, Lev; Pakes, Chris; Moriarty, Philip

    2012-06-01

    The chemical reactivity of the tip plays a central role in image formation in dynamic force microscopy, but in very many cases the state of the probe is a key experimental unknown. We show here that an H-terminated and thus chemically unreactive tip can be readily identified via characteristic imaging and spectroscopic (F(z)) signatures, including, in particular, contrast inversion, on hydrogen-passivated Si(100). We determine the tip apex termination by comparing site-specific difference force curves with the results of density functional theory, providing a clear protocol for the identification of chemically unreactive tips on silicon surfaces.

  10. In vitro propagation of peanut (Arachis hypogaea L.) by shoot tip culture.

    PubMed

    Ozudogru, Elif Aylin; Kaya, Ergun; Lambardi, Maurizio

    2013-01-01

    Peanut (Arachis hypogaea L.), also known as groundnut, is the most important species of Arachis genus, originating from Brazil and Peru. Peanut seeds contain high seed oil, proteins, amino acids, and vitamin E, and are consumed worldwide as edible nut, peanut butter, or candy, and peanut oil extracted from the seeds. The meal remaining after oil extraction is also used for animal feed. However, its narrow germplasm base, together with susceptibility to diseases, pathogens, and weeds, decreases yield and seed quality and causes great economic losses annually. Hence, the optimization of efficient in vitro propagation procedures would be highly effective for peanut propagation, as it would raise yield and improve seed quality and flavor. Earlier reports on traditional micropropagation methods, based on axillary bud proliferation which guarantees the multiplication of true-to-type plants, are still limited. This chapter describes a micropropagation protocol to improve multiple shoot formation from shoot-tip explants by using AgNO(3) in combination with plant growth regulators.

  11. Using the Real-Ear-to-Coupler Difference within the American Academy of Audiology Pediatric Amplification Guideline: Protocols for Applying and Predicting Earmold RECDs.

    PubMed

    Moodie, Sheila; Pietrobon, Jonathan; Rall, Eileen; Lindley, George; Eiten, Leisha; Gordey, Dave; Davidson, Lisa; Moodie, K Shane; Bagatto, Marlene; Haluschak, Meredith Magathan; Folkeard, Paula; Scollie, Susan

    2016-03-01

    Real-ear-to-coupler difference (RECD) measurements are used for the purposes of estimating degree and configuration of hearing loss (in dB SPL ear canal) and predicting hearing aid output from coupler-based measures. Accurate measurements of hearing threshold, derivation of hearing aid fitting targets, and predictions of hearing aid output in the ear canal assume consistent matching of RECD coupling procedure (i.e., foam tip or earmold) with that used during assessment and in verification of the hearing aid fitting. When there is a mismatch between these coupling procedures, errors are introduced. The goal of this study was to quantify the systematic difference in measured RECD values obtained when using a foam tip versus an earmold with various tube lengths. Assuming that systematic errors exist, the second goal was to investigate the use of a foam tip to earmold correction for the purposes of improving fitting accuracy when mismatched RECD coupling conditions occur (e.g., foam tip at assessment, earmold at verification). Eighteen adults and 17 children (age range: 3-127 mo) participated in this study. Data were obtained using simulated ears of various volumes and earmold tubing lengths and from patients using their own earmolds. Derived RECD values based on simulated ear measurements were compared with RECD values obtained for adult and pediatric ears for foam tip and earmold coupling. Results indicate that differences between foam tip and earmold RECDs are consistent across test ears for adults and children which support the development of a correction between foam tip and earmold couplings for RECDs that can be applied across individuals. The foam tip to earmold correction values developed in this study can be used to provide improved estimations of earmold RECDs. This may support better accuracy in acoustic transforms related to transforming thresholds and/or hearing aid coupler responses to ear canal sound pressure level for the purposes of fitting behind-the-ear hearing aids. American Academy of Audiology.

  12. Efficient regeneration of sorghum, Sorghum bicolor (L.) Moench, from shoot-tip explant.

    PubMed

    Syamala, D; Devi, Prathibha

    2003-12-01

    Novel protocols for production of multiple shoot-tip clumps and somatic embryos of Sorghum bicolor (L.) Moench were developed with long-term goal of crop improvement through genetic transformation. Multiple shoot-tip clumps were developed in vitro from shoot-tip explant of one-week old seedling, cultured on MS medium containing only BA (0.5, 1 or 2 mg/l) or both BA (1 or 2 mg/l) and 2,4-D (0.5 mg/l) with bi-weekly subculture. Somatic embryos were directly produced on the enlarged dome shaped growing structures that developed from the shoot-tips of one-week old seedling explants (without any callus formation) when cultured on MS medium supplemented with both 2,4-D (0.5 mg/l) and BA (0.5 mg/l). However, the supplementation of MS medium with only 2,4-D (0.5 mg/l) induced compact callus without any plantlet regeneration. Each multiple shoot-clump was capable of regenerating more than 80 shoots via an intensive differentiation of both axillary and adventitious shoot buds, the somatic embryos were capable of 90% germination, plant conversion and regeneration. The regenerated shoots could be efficiently rooted on MS medium containing indole-3-butyric acid (IBA 1 mg/l). The plants were successfully transplanted to glasshouse and grown to maturity with a survival rate of 98%. Morphogenetic response of the explants was found to be genotypically independent.

  13. Next Generation Sequence Assembly with AMOS

    PubMed Central

    Treangen, Todd J; Sommer, Dan D; Angly, Florent E; Koren, Sergey; Pop, Mihai

    2011-01-01

    A Modular Open-Source Assembler (AMOS) was designed to offer a modular approach to genome assembly. AMOS includes a wide range of tools for assembly, including lightweight de novo assemblers Minimus and Minimo, and Bambus 2, a robust scaffolder able to handle metagenomic and polymorphic data. This protocol describes how to configure and use AMOS for the assembly of Next Generation sequence data. Additionally, we provide three tutorial examples that include bacterial, viral, and metagenomic datasets with specific tips for improving assembly quality. PMID:21400694

  14. Protocol for Removal of Third Molar Root Tips from the Inferior Alveolar Canal-Crossing the line.

    PubMed

    Punga, Rohit; Keswani, Kiran

    2014-12-01

    The safe removal of third molars involved with the inferior alveolar canal (IAC) has been an area of concern since long. Many times we hesitate for the removal of third molars, fearing injury to the inferior alveolar nerve. The authors here describe a simple technique which can be used to remove third molars showing evidence of proximity to IAC on presurgical radiographic evaluation, as well as those root tips which, during removal, accidentally enter the IAC space. A step-by-step protocol is presented along with necessary precautions during the operative procedure.

  15. Writing Interview Protocols and Conducting Interviews: Tips for Students New to the Field of Qualitative Research

    ERIC Educational Resources Information Center

    Jacob, Stacy A.; Furgerson, S. Paige

    2012-01-01

    Students new to doing qualitative research in the ethnographic and oral traditions, often have difficulty creating successful interview protocols. This article offers practical suggestions for students new to qualitative research for both writing interview protocol that elicit useful data and for conducting the interview. This piece was originally…

  16. Evaluation of Methods to Improve the Extraction and Recovery of DNA from Cotton Swabs for Forensic Analysis

    PubMed Central

    Adamowicz, Michael S.; Stasulli, Dominique M.; Sobestanovich, Emily M.; Bille, Todd W.

    2014-01-01

    Samples for forensic DNA analysis are often collected from a wide variety of objects using cotton or nylon tipped swabs. Testing has shown that significant quantities of DNA are retained on the swab, however, and subsequently lost. When processing evidentiary samples, the recovery of the maximum amount of available DNA is critical, potentially dictating whether a usable profile can be derived from a piece of evidence or not. The QIAamp DNA Investigator extraction kit was used with its recommended protocol for swabs (one hour incubation at 56°C) as a baseline. Results indicate that over 50% of the recoverable DNA may be retained on the cotton swab tip, or otherwise lost, for both blood and buccal cell samples when using this protocol. The protocol’s incubation time and temperature were altered, as was incubating while shaking or stationary to test for increases in recovery efficiency. An additional step was then tested that included periodic re-suspension of the swab tip in the extraction buffer during incubation. Aliquots of liquid blood or a buccal cell suspension were deposited and dried on cotton swabs and compared with swab-less controls. The concentration of DNA in each extract was quantified and STR analysis was performed to assess the quality of the extracted DNA. Stationary incubations and those performed at 65°C did not result in significant gains in DNA yield. Samples incubated for 24 hours yielded less DNA. Increased yields were observed with three and 18 hour incubation periods. Increases in DNA yields were also observed using a swab re-suspension method for both cell types. The swab re-suspension method yielded an average two-fold increase in recovered DNA yield with buccal cells and an average three-fold increase with blood cells. These findings demonstrate that more of the DNA collected on swabs can be recovered with specific protocol alterations. PMID:25549111

  17. Generation and Long-term Maintenance of Nerve-free Hydra.

    PubMed

    Tran, Cassidy M; Fu, Sharon; Rowe, Trevor; Collins, Eva-Maria S

    2017-07-07

    The interstitial cell lineage of Hydra includes multipotent stem cells, and their derivatives: gland cells, nematocytes, germ cells, and nerve cells. The interstitial cells can be eliminated through two consecutive treatments with colchicine, a plant-derived toxin that kills dividing cells, thus erasing the potential for renewal of the differentiated cells that are derived from the interstitial stem cells. This allows for the generation of Hydra that lack nerve cells. A nerve-free polyp cannot open its mouth to feed, egest, or regulate osmotic pressure. Such animals, however, can survive and be cultured indefinitely in the laboratory if regularly force-fed and burped. The lack of nerve cells allows for studies of the role of the nervous system in regulating animal behavior and regeneration. Previously published protocols for nerve-free Hydra maintenance involve outdated techniques such as mouth-pipetting with hand-pulled micropipette tips to feed and clean the Hydra. Here, an improved protocol for maintenance of nerve-free Hydra is introduced. Fine-tipped forceps are used to force open the mouth and insert freshly killed Artemia. Following force-feeding, the body cavity of the animal is flushed with fresh medium using a syringe and hypodermic needle to remove undigested material, referred to here as "burping". This new method of force-feeding and burping nerve-free Hydra through the use of forceps and syringes eliminates the need for mouth-pipetting using hand-pulled micropipette tips. It thus makes the process safer and significantly more time efficient. To ensure that the nerve cells in the hypostome have been eliminated, immunohistochemistry using anti-tyrosine-tubulin is conducted.

  18. Digital subtraction angiography during transjugular intrahepatic portosystemic shunt creation or revision: data on radiation exposure and image quality obtained using a standard and a low-dose acquisition protocol in a flat-panel detector-based system.

    PubMed

    Miraglia, Roberto; Maruzzelli, Luigi; Cortis, Kelvin; Tafaro, Corrado; Gerasia, Roberta; Parisi, Carmelo; Luca, Angelo

    2015-08-01

    To determine whether the use of a low-dose acquisition protocol (LDP) in digital subtraction angiography during transjugular intrahepatic portosystemic shunt (TIPS) creation/revision results in significant reduction of patient radiation exposure and adequate image quality, as compared to a default reference standard-dose acquisition protocol (SDP). Two angiographic runs were performed during TIPS creation/revision: the first following catheterization of the portal venous system and the second after stent deployment/angioplasty. Constant field of view, object to image-detector distance, and source to image-receptor distance were maintained in each patient during the two angiographic runs. 17 consecutive adult patients who underwent TIPS creation (n = 11) or TIPS revision (n = 6) from December 2013 to March 2014 were considered eligible for this single centre prospective study. In each patient, the LDP and the SDP were used in a random order for the two runs, with each patient serving as his/her own control. The dose-area product (DAP) was calculated for each image and compared. Image quality was graded by two interventional radiologists other than the operator. In all runs acquired with the LDP, image quality was considered adequate for a successful procedural outcome. The DAP per image of the LDP was numerically inferior as compared to the DAP per image of the SDP in all patients. The mean reduction in DAP per image was 75.24% ± 5.7% (p < 0. 001). Radiation exposure during TIPS creation/revision was significantly reduced by selecting a LDP in our flat-panel detector-based system, while maintaining adequate image quality.

  19. Using semantics for representing experimental protocols.

    PubMed

    Giraldo, Olga; García, Alexander; López, Federico; Corcho, Oscar

    2017-11-13

    An experimental protocol is a sequence of tasks and operations executed to perform experimental research in biological and biomedical areas, e.g. biology, genetics, immunology, neurosciences, virology. Protocols often include references to equipment, reagents, descriptions of critical steps, troubleshooting and tips, as well as any other information that researchers deem important for facilitating the reusability of the protocol. Although experimental protocols are central to reproducibility, the descriptions are often cursory. There is the need for a unified framework with respect to the syntactic structure and the semantics for representing experimental protocols. In this paper we present "SMART Protocols ontology", an ontology for representing experimental protocols. Our ontology represents the protocol as a workflow with domain specific knowledge embedded within a document. We also present the S ample I nstrument R eagent O bjective (SIRO) model, which represents the minimal common information shared across experimental protocols. SIRO was conceived in the same realm as the Patient Intervention Comparison Outcome (PICO) model that supports search, retrieval and classification purposes in evidence based medicine. We evaluate our approach against a set of competency questions modeled as SPARQL queries and processed against a set of published and unpublished protocols modeled with the SP Ontology and the SIRO model. Our approach makes it possible to answer queries such as Which protocols use tumor tissue as a sample. Improving reporting structures for experimental protocols requires collective efforts from authors, peer reviewers, editors and funding bodies. The SP Ontology is a contribution towards this goal. We build upon previous experiences and bringing together the view of researchers managing protocols in their laboratory work. Website: https://smartprotocols.github.io/ .

  20. Spatially resolved quantitative mapping of thermomechanical properties and phase transition temperatures using scanning probe microscopy

    DOEpatents

    Jesse, Stephen; Kalinin, Sergei V; Nikiforov, Maxim P

    2013-07-09

    An approach for the thermomechanical characterization of phase transitions in polymeric materials (polyethyleneterephthalate) by band excitation acoustic force microscopy is developed. This methodology allows the independent measurement of resonance frequency, Q factor, and oscillation amplitude of a tip-surface contact area as a function of tip temperature, from which the thermal evolution of tip-surface spring constant and mechanical dissipation can be extracted. A heating protocol maintained a constant tip-surface contact area and constant contact force, thereby allowing for reproducible measurements and quantitative extraction of material properties including temperature dependence of indentation-based elastic and loss moduli.

  1. Next generation sequence assembly with AMOS.

    PubMed

    Treangen, Todd J; Sommer, Dan D; Angly, Florent E; Koren, Sergey; Pop, Mihai

    2011-03-01

    A Modular Open-Source Assembler (AMOS) was designed to offer a modular approach to genome assembly. AMOS includes a wide range of tools for assembly, including the lightweight de novo assemblers Minimus and Minimo, and Bambus 2, a robust scaffolder able to handle metagenomic and polymorphic data. This protocol describes how to configure and use AMOS for the assembly of Next Generation sequence data. Additionally, we provide three tutorial examples that include bacterial, viral, and metagenomic datasets with specific tips for improving assembly quality. © 2011 by John Wiley & Sons, Inc.

  2. Photoacoustic shock wave emission and cavitation from structured optical fiber tips

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohammadzadeh, M.; Gonzalez-Avila, S. R.; Ohl, C. D., E-mail: cdohl@ntu.edu.sg

    Photoacoustic waves generated at the tip of an optical fiber consist of a compressive shock wave followed by tensile diffraction waves. These tensile waves overlap along the fiber axis and form a cloud of cavitation bubbles. We demonstrate that shaping the fiber tip through micromachining alters the number and direction of the emitted waves and cavitation clouds. Shock wave emission and cavitation patterns from five distinctively shaped fiber tips have been studied experimentally and compared to a linear wave propagation model. In particular, multiple shock wave emission and generation of strong tension away from the fiber axis have been realizedmore » using modified fiber tips. These altered waveforms may be applied for novel microsurgery protocols, such as fiber-based histotripsy, by utilizing bubble-shock wave interaction.« less

  3. Cultivar-Dependent Direct Organogenesis of Date Palm from Shoot Tip Explants.

    PubMed

    Abahmane, Larbi

    2017-01-01

    A number of public and private laboratories are working on date palm micropropagation to meet the increasing worldwide demand for date palm planting material. A standardized direct organogenesis protocol exists for the production of date palm plantlets to maintain the genetic fidelity of regenerated plants. Organogenesis has the advantage of using low concentrations of plant growth regulators and avoiding the callus phase. In addition, direct regeneration of vegetative buds minimizes the risk of somaclonal variation among plant regenerants. However, in vitro multiplication cycles should be limited in duration by frequent renewal of plant material. This chapter describes a simple and routine organogenesis protocol for date palm multiplication using shoot tip explants.

  4. Automated extraction of single H atoms with STM: tip state dependency

    NASA Astrophysics Data System (ADS)

    Møller, Morten; Jarvis, Samuel P.; Guérinet, Laurent; Sharp, Peter; Woolley, Richard; Rahe, Philipp; Moriarty, Philip

    2017-02-01

    The atomistic structure of the tip apex plays a crucial role in performing reliable atomic-scale surface and adsorbate manipulation using scanning probe techniques. We have developed an automated extraction routine for controlled removal of single hydrogen atoms from the H:Si(100) surface. The set of atomic extraction protocols detect a variety of desorption events during scanning tunneling microscope (STM)-induced modification of the hydrogen-passivated surface. The influence of the tip state on the probability for hydrogen removal was examined by comparing the desorption efficiency for various classifications of STM topographs (rows, dimers, atoms, etc). We find that dimer-row-resolving tip apices extract hydrogen atoms most readily and reliably (and with least spurious desorption), while tip states which provide atomic resolution counter-intuitively have a lower probability for single H atom removal.

  5. Evaluation of effectiveness of Er,Cr:YSGG laser for root canal disinfection: theoretical simulation of temperature elevations in root dentin.

    PubMed

    Zhu, L; Tolba, M; Arola, D; Salloum, M; Meza, F

    2009-07-01

    Erbium, chromium: yttrium, scandium, gallium, garnet (Er,Cr:YSGG) lasers are currently being investigated for disinfecting the root canal system. Prior to using laser therapy, it is important to understand the temperature distribution and to assess thermal damage to the surrounding tissue. In this study, a theoretical simulation using the Pennes bioheat equation is conducted to evaluate how heat spreads from the canal surface using an Er,Cr:YSGG laser. Results of the investigation show that some of the proposed treatment protocols for killing bacteria in the deep dentin are ineffective, even for long heating durations. Based on the simulation, an alternative treatment protocol is identified that has improved effectiveness and is less likely to introduce collateral damage to the surrounding tissue. The alternative protocol uses 350 mW laser power with repeating laser tip movement to achieve bacterial disinfection in the deep dentin (800 microm lateral from the canal surface), while avoiding thermal damage to the surrounding tissue (T<47 degrees C). The alternative treatment protocol has the potential to not only achieve bacterial disinfection of deep dentin but also shorten the treatment time, thereby minimizing potential patient discomfort during laser procedures.

  6. Gerbera micropropagation.

    PubMed

    Cardoso, Jean C; Teixeira da Silva, Jaime A

    2013-12-01

    Gerbera jamesonii (gerbera) is an important cut-flower in the global floricultural industry. Micropropagation is the main system used to clonally propagate gerbera in vitro resulting in the production of millions of plantlets each year. Numerous types of explants and protocols for micropropagation have been established and used for gerbera. Shoot tips are the commonly used explant while adventitious shoot induction from the capitulum is also a popular method. Most papers in the literature have focused on testing the influence of different types and combinations of plant growth regulators with the aim of improving the regeneration and multiplication stage of one or few cultivars. Genotype is one of the most influential factors on the response of gerbera in vitro. Despite this, no successful universal protocol has yet been developed for multiple cultivars, limiting the usefulness of current protocols for commercial biotechnology labs. Slow-growing endogenous bacteria are one of the most important problems in gerbera micropropagation but require more studies on control and prevention. Individual shoots are normally easy to root, usually in excess of 90% of plantlets, but the acclimatization stage requires improvements and new technologies to increase the survival of plants. Epigenetic variations in micropropagated gerbera are frequently observed only with high concentrations of cytokinins in the culture medium but somaclonal variation is rare. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. High-throughput, automated extraction of DNA and RNA from clinical samples using TruTip technology on common liquid handling robots.

    PubMed

    Holmberg, Rebecca C; Gindlesperger, Alissa; Stokes, Tinsley; Brady, Dane; Thakore, Nitu; Belgrader, Philip; Cooney, Christopher G; Chandler, Darrell P

    2013-06-11

    TruTip is a simple nucleic acid extraction technology whereby a porous, monolithic binding matrix is inserted into a pipette tip. The geometry of the monolith can be adapted for specific pipette tips ranging in volume from 1.0 to 5.0 ml. The large porosity of the monolith enables viscous or complex samples to readily pass through it with minimal fluidic backpressure. Bi-directional flow maximizes residence time between the monolith and sample, and enables large sample volumes to be processed within a single TruTip. The fundamental steps, irrespective of sample volume or TruTip geometry, include cell lysis, nucleic acid binding to the inner pores of the TruTip monolith, washing away unbound sample components and lysis buffers, and eluting purified and concentrated nucleic acids into an appropriate buffer. The attributes and adaptability of TruTip are demonstrated in three automated clinical sample processing protocols using an Eppendorf epMotion 5070, Hamilton STAR and STARplus liquid handling robots, including RNA isolation from nasopharyngeal aspirate, genomic DNA isolation from whole blood, and fetal DNA extraction and enrichment from large volumes of maternal plasma (respectively).

  8. Identifying tips for intramolecular NC-AFM imaging via in situ fingerprinting

    NASA Astrophysics Data System (ADS)

    Sang, Hongqian; Jarvis, Samuel P.; Zhou, Zhichao; Sharp, Peter; Moriarty, Philip; Wang, Jianbo; Wang, Yu; Kantorovich, Lev

    2014-10-01

    A practical experimental strategy is proposed that could potentially enable greater control of the tip apex in non-contact atomic force microscopy experiments. It is based on a preparation of a structure of interest alongside a reference surface reconstruction on the same sample. Our proposed strategy is as follows. Spectroscopy measurements are first performed on the reference surface to identify the tip apex structure using a previously collected database of responses of different tips to this surface. Next, immediately following the tip identification protocol, the surface of interest is studied (imaging, manipulation and/or spectroscopy). The prototype system we choose is the mixed Si(111)-7×7 and surface which can be prepared on the same sample with a controlled ratio of reactive and passivated regions. Using an ``in silico'' approach based on ab initio density functional calculations and a set of tips with varying chemical reactivities, we show how one can perform tip fingerprinting using the Si(111)-7×7 reference surface. Then it is found by examining the imaging of a naphthalene tetracarboxylic diimide (NTCDI) molecule adsorbed on surface that negatively charged tips produce the best intramolecular contrast attributed to the enhancement of repulsive interactions.

  9. Intermodulation Atomic Force Microscopy and Spectroscopy

    NASA Astrophysics Data System (ADS)

    Hutter, Carsten; Platz, Daniel; Tholen, Erik; Haviland, David; Hansson, Hans

    2009-03-01

    We present a powerful new method of dynamic AFM, which allows to gain far more information about the tip-surface interaction than standard amplitude or phase imaging, while scanning at comparable speed. Our method, called intermodulation atomic force microscopy (ImAFM), employs the manifestly nonlinear phenomenon of intermodulation to extract information about tip-surface forces. ImAFM uses one eigenmode of a mechanical resonator, the latter driven at two frequencies to produce many spectral peaks near its resonace, where sensitivity is highest [1]. We furthermore present a protocol for decoding the combined information encoded in the spectrum of intermodulation peaks. Our theoretical framework suggests methods to enhance the gained information by using a different parameter regime as compared to Ref. [1]. We also discuss strategies for solving the inverse problem, i.e., for extracting the nonlinear tip-surface interaction from the response, also naming limitations of our theoretical analysis. We will further report on latest progress to experimentally employ our new protocol.[3pt] [1] D. Platz, E. A. Tholen, D. Pesen, and D. B. Haviland, Appl. Phys. Lett. 92, 153106 (2008).

  10. A combined Surface Enhanced Raman Spectroscopy (SERS)/UV-vis approach for the investigation of dye content in commercial felt tip pens inks.

    PubMed

    Saviello, Daniela; Trabace, Maddalena; Alyami, Abeer; Mirabile, Antonio; Giorgi, Rodorico; Baglioni, Piero; Iacopino, Daniela

    2018-05-01

    The development of protocols for the protection of the large patrimony of works of art created by felt tip pen media since the 1950's requires detailed knowledge of the main dyes constituting commercial ink mixtures. In this work Surface Enhanced Raman Scattering (SERS) and UV-vis spectroscopy were used for the first time for the systematic identification of dye composition in commercial felt tip pens. A large selection of pens comprising six colors of five different brands was analyzed. Intense SERS spectra were obtained for all colors, allowing identification of main dye constituents. Poinceau 4R and Eosin dyes were found to be the main constituents of red and pink colors; Rhodamine and Tartrazine were found in orange and yellow colors; Erioglaucine was found in green and blue colors. UV-vis analysis of the same inks was used to support SERS findings but also to unequivocally assign some uncertain dye identifications, especially for yellow and orange colors. The spectral data of all felt tip pens collected through this work were assembled in a database format. The data obtained through this systematic investigation constitute the basis for the assembly of larger reference databases that ultimately will support the development of conservation protocols for the long term preservation of modern art collections. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Percutaneous Pulmonary Embolism Thrombectomy and Thrombolysis: Technical Tips and Tricks.

    PubMed

    Devcic, Zlatko; Kuo, William T

    2018-06-01

    Catheter-directed therapy (CDT) is now acknowledged as a treatment option for select patients with acute massive or submassive pulmonary embolism (PE), and more patients are being considered for CDT if there is available expertise. Therefore, interventionalists should be aware of the variety of catheter-based treatment options, specific pitfalls to avoid during therapy, and the appropriate treatment endpoints. This article reviews currently available techniques and protocols for treating acute massive and submassive PE, with tips to safely and successfully perform percutaneous PE interventions.

  12. Chemically etched fiber tips for near-field optical microscopy: a process for smoother tips.

    PubMed

    Lambelet, P; Sayah, A; Pfeffer, M; Philipona, C; Marquis-Weible, F

    1998-11-01

    An improved method for producing fiber tips for scanning near-field optical microscopy is presented. The improvement consists of chemically etching quartz optical fibers through their acrylate jacket. This new method is compared with the previous one in which bare fibers were etched. With the new process the meniscus formed by the acid along the fiber does not move during etching, leading to a much smoother surface of the tip cone. Subsequent metallization is thus improved, resulting in better coverage of the tip with an aluminum opaque layer. Our results show that leakage can be avoided along the cone, and light transmission through the tip is spatially limited to an optical aperture of a 100-nm dimension.

  13. Femtosecond laser micromachining of compound parabolic concentrator fiber tipped glucose sensors.

    PubMed

    Hassan, Hafeez Ul; Lacraz, Amédée; Kalli, Kyriacos; Bang, Ole

    2017-03-01

    We report on highly accurate femtosecond (fs) laser micromachining of a compound parabolic concentrator (CPC) fiber tip on a polymer optical fiber (POF). The accuracy is reflected in an unprecedented correspondence between the numerically predicted and experimentally found improvement in fluorescence pickup efficiency of a Förster resonance energy transfer-based POF glucose sensor. A Zemax model of the CPC-tipped sensor predicts an optimal improvement of a factor of 3.96 compared to the sensor with a plane-cut fiber tip. The fs laser micromachined CPC tip showed an increase of a factor of 3.5, which is only 11.6% from the predicted value. Earlier state-of-the-art fabrication of the CPC-shaped tip by fiber tapering was of so poor quality that the actual improvement was 43% lower than the predicted improvement of the ideal CPC shape.

  14. Femtosecond laser micromachining of compound parabolic concentrator fiber tipped glucose sensors

    NASA Astrophysics Data System (ADS)

    Hassan, Hafeez Ul; Lacraz, Amédée; Kalli, Kyriacos; Bang, Ole

    2017-03-01

    We report on highly accurate femtosecond (fs) laser micromachining of a compound parabolic concentrator (CPC) fiber tip on a polymer optical fiber (POF). The accuracy is reflected in an unprecedented correspondence between the numerically predicted and experimentally found improvement in fluorescence pickup efficiency of a Förster resonance energy transfer-based POF glucose sensor. A Zemax model of the CPC-tipped sensor predicts an optimal improvement of a factor of 3.96 compared to the sensor with a plane-cut fiber tip. The fs laser micromachined CPC tip showed an increase of a factor of 3.5, which is only 11.6% from the predicted value. Earlier state-of-the-art fabrication of the CPC-shaped tip by fiber tapering was of so poor quality that the actual improvement was 43% lower than the predicted improvement of the ideal CPC shape.

  15. Method to improve the blade tip-timing accuracy of fiber bundle sensor under varying tip clearance

    NASA Astrophysics Data System (ADS)

    Duan, Fajie; Zhang, Jilong; Jiang, Jiajia; Guo, Haotian; Ye, Dechao

    2016-01-01

    Blade vibration measurement based on the blade tip-timing method has become an industry-standard procedure. Fiber bundle sensors are widely used for tip-timing measurement. However, the variation of clearance between the sensor and the blade will bring a tip-timing error to fiber bundle sensors due to the change in signal amplitude. This article presents methods based on software and hardware to reduce the error caused by the tip clearance change. The software method utilizes both the rising and falling edges of the tip-timing signal to determine the blade arrival time, and a calibration process suitable for asymmetric tip-timing signals is presented. The hardware method uses an automatic gain control circuit to stabilize the signal amplitude. Experiments are conducted and the results prove that both methods can effectively reduce the impact of tip clearance variation on the blade tip-timing and improve the accuracy of measurements.

  16. Optimization of an Active Twist Rotor Blade Planform for Improved Active Response and Forward Flight Performance

    NASA Technical Reports Server (NTRS)

    Sekula, Martin K; Wilbur, Matthew L.

    2014-01-01

    A study was conducted to identify the optimum blade tip planform for a model-scale active twist rotor. The analysis identified blade tip design traits which simultaneously reduce rotor power of an unactuated rotor while leveraging aeromechanical couplings to tailor the active response of the blade. Optimizing the blade tip planform for minimum rotor power in forward flight provided a 5 percent improvement in performance compared to a rectangular blade tip, but reduced the vibration control authority of active twist actuation by 75 percent. Optimizing for maximum blade twist response increased the vibration control authority by 50 percent compared to the rectangular blade tip, with little effect on performance. Combined response and power optimization resulted in a blade tip design which provided similar vibration control authority to the rectangular blade tip, but with a 3.4 percent improvement in rotor performance in forward flight.

  17. Expanding torque possibilities: A skeletally anchored torqued cantilever for uprighting "kissing molars".

    PubMed

    Barros, Sérgio Estelita; Janson, Guilherme; Chiqueto, Kelly; Ferreira, Eduardo; Rösing, Cassiano

    2018-04-01

    Several uprighting mechanics and devices have been used for repositioning tipped molars. "Kissing molars" (KMs) are an uncommon tooth impaction involving 2 severely tipped mandibular molars with their occlusal surfaces positioned crown to crown, with the roots pointing in opposite directions. Orthodontic uprighting of KMs has not been a usual treatment protocol, and it can be a challenging task due to the severe tipping and double impaction, requiring efficient and well-controlled uprighting mechanics. An innovative skeletally anchored cantilever, which uses the torque principle for uprighting tipped molars, is suggested. This torqued cantilever is easy to manufacture, install, and activate; it is a well-known torque that is effective for producing root movement. A successful treatment of symptomatic KMs, involving the first and second molars, was achieved with this cantilever. Thus, clinicians should consider the suggested uprighting mechanics and orthodontic device as a more conservative alternative to extraction of KMs, depending on the patient's age, involved teeth in KMs, tipping severity, and impaction positions. Copyright © 2018 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  18. Transjugular intrahepatic portosystemic shunt: impact on systemic hemodynamics and renal and cardiac function in patients with cirrhosis.

    PubMed

    Busk, Troels M; Bendtsen, Flemming; Poulsen, Jørgen H; Clemmesen, Jens O; Larsen, Fin S; Goetze, Jens P; Iversen, Jens S; Jensen, Magnus T; Møgelvang, Rasmus; Pedersen, Erling B; Bech, Jesper N; Møller, Søren

    2018-02-01

    Transjugular intrahepatic portosystemic shunt (TIPS) alleviates portal hypertension and possibly increases central blood volume (CBV). Moreover, renal function often improves; however, its effects on cardiac function are unclear. The aims of our study were to examine the effects of TIPS on hemodynamics and renal and cardiac function in patients with cirrhosis. In 25 cirrhotic patients, we analyzed systemic, cardiac, and splanchnic hemodynamics by catheterization of the liver veins and right heart chambers before and 1 wk after TIPS. Additionally, we measured renal and cardiac markers and performed advanced echocardiography before, 1 wk after, and 4 mo after TIPS. CBV increased significantly after TIPS (+4.6%, P < 0.05). Cardiac output (CO) increased (+15.3%, P < 0.005) due to an increase in stroke volume (SV) (+11.1%, P < 0.005), whereas heart rate (HR) was initially unchanged. Cardiopulmonary pressures increased after TIPS, whereas copeptin, a marker of vasopressin, decreased (-18%, P < 0.005) and proatrial natriuretic peptide increased (+52%, P < 0.0005) 1 wk after TIPS and returned to baseline 4 mo after TIPS. Plasma neutrophil gelatinase-associated lipocalin, renin, aldosterone, and serum creatinine decreased after TIPS (-36%, P < 0.005; -65%, P < 0.05; -90%, P < 0.005; and -13%, P < 0.005, respectively). Echocardiography revealed subtle changes in cardiac function after TIPS, although these were within the normal range. TIPS increases CBV by increasing CO and SV, whereas HR is initially unaltered. These results indicate an inability to increase the heart rate in response to a hemodynamic challenge that only partially increases CBV after TIPS. These changes, however, are sufficient for improving renal function. NEW & NOTEWORTHY For the first time, we have combined advanced techniques to study the integrated effects of transjugular intrahepatic portosystemic shunt (TIPS) in cirrhosis. We showed that TIPS increases central blood volume (CBV) through improved cardiac inotropy. Advanced echocardiography demonstrated that myocardial function was unaffected by the dramatic increase in preload after TIPS. Finally, renal function improved due to the increase in CBV. Recognition of these physiological changes significantly contributes to our clinical understanding of TIPS.

  19. Methods for Improving the Curvature of Steerable Needles in Biological Tissue

    PubMed Central

    Adebar, Troy K.; Greer, Joseph D.; Laeseke, Paul F.; Hwang, Gloria L.; Okamura, Allison M.

    2016-01-01

    Robotic needle steering systems have the potential to improve percutaneous interventions such as radiofrequency ablation of liver tumors, but steering techniques described to date have not achieved sufficiently small radius of curvature in biological tissue to be relevant to this application. In this work, the impact of tip geometry on steerable needle curvature is examined. Finite-element simulations and experiments with bent-tip needles in ex vivo liver tissue demonstrate that selection of tip length and angle can greatly improve curvature, with radius of curvature below 5 cm in liver tissue possible through judicious selection of these parameters. Motivated by the results of this analysis, a new articulated-tip steerable needle is described, in which a distal section is actively switched by a robotic system between a straight tip (resulting in a straight path) and a bent tip (resulting in a curved path). This approach allows the tip length and angle to be increased, while the straight configuration allows the needle tip to still pass through an introducer sheath and rotate inside the body. Validation testing in liver tissue shows that the new articulated-tip steerable needle achieves smaller radius of curvature compared to bent-tip needles described in previous work. Steerable needles with optimized tip parameters, which can generate tight curves in liver tissue, increase the clinical relevance of needle steering to percutaneous interventions. PMID:26441438

  20. Imaging and analysis of individual cavitation microbubbles around dental ultrasonic scalers.

    PubMed

    Vyas, N; Dehghani, H; Sammons, R L; Wang, Q X; Leppinen, D M; Walmsley, A D

    2017-11-01

    Cavitation is a potentially effective and less damaging method of removing biofilm from biomaterial surfaces. The aim of this study is to characterise individual microbubbles around ultrasonic scaler tips using high speed imaging and image processing. This information will provide improved understanding on the disruption of dental biofilm and give insights into how the instruments can be optimised for ultrasonic cleaning. Individual cavitation microbubbles around ultrasonic scalers were analysed using high speed recordings up to a million frames per second with image processing of the bubble movement. The radius and rate of bubble growth together with the collapse was calculated by tracking multiple points on bubbles over time. The tracking method to determine bubble speed demonstrated good inter-rater reliability (intra class correlation coefficient: 0.993) and can therefore be a useful method to apply in future studies. The bubble speed increased over its oscillation cycle and a maximum of 27ms -1 was recorded during the collapse phase. The maximum bubble radii ranged from 40 to 80μm. Bubble growth was observed when the ultrasonic scaler tip receded from an area and similarly bubble collapse was observed when the tip moved towards an area, corresponding to locations of low pressure around the scaler tip. Previous work shows that this cavitation is involved in biofilm removal. Future experimental work can be based on these findings by using the protocols developed to experimentally analyse cavitation around various clinical instruments and comparing with theoretical calculations. This will help to determine the main cleaning mechanisms of cavitation and how clinical instruments such as ultrasonic scalers can be optimised. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  1. Vitrification-based cryopreservation of shoot-tips of Pinus kesiya Royle ex. Gord.

    PubMed

    Kalita, V; Choudhury, H; Kumaria, S; Tandon, P

    2012-01-01

    The present investigation was aimed at developing a protocol for long-term preservation of germplasm of Pinus kesiya Royle ex. Gord. through vitrification. Some of the critical components affecting explant tolerance to cryopreservation, such as effects of preculture, vitrification solutions, exposure time to vitrification solutions, volume of vitrification solution and its toxicity, washing of vitrified tissues after thawing, were analysed. The results showed that shoot regrowth of P. kesiya shoot-tips was considerably affected when exposed to cryoprotectants for longer periods of time (longer than 10 min). Among different vitrification solutions studied, maximum survival (76 percent) of shoot-tips was achieved with mVSL (using 0.6 ml of the solution) in MS basal medium containing 4.0 mg l-1 N6-benzyladenine (BA).

  2. Investigating single molecule adhesion by atomic force spectroscopy.

    PubMed

    Stetter, Frank W S; Kienle, Sandra; Krysiak, Stefanie; Hugel, Thorsten

    2015-02-27

    Atomic force spectroscopy is an ideal tool to study molecules at surfaces and interfaces. An experimental protocol to couple a large variety of single molecules covalently onto an AFM tip is presented. At the same time the AFM tip is passivated to prevent unspecific interactions between the tip and the substrate, which is a prerequisite to study single molecules attached to the AFM tip. Analyses to determine the adhesion force, the adhesion length, and the free energy of these molecules on solid surfaces and bio-interfaces are shortly presented and external references for further reading are provided. Example molecules are the poly(amino acid) polytyrosine, the graft polymer PI-g-PS and the phospholipid POPE (1-palmitoyl-2-oleoyl-sn-glycero-3-phosphoethanolamine). These molecules are desorbed from different surfaces like CH3-SAMs, hydrogen terminated diamond and supported lipid bilayers under various solvent conditions. Finally, the advantages of force spectroscopic single molecule experiments are discussed including means to decide if truly a single molecule has been studied in the experiment.

  3. Investigating Single Molecule Adhesion by Atomic Force Spectroscopy

    PubMed Central

    Stetter, Frank W. S.; Kienle, Sandra; Krysiak, Stefanie; Hugel, Thorsten

    2015-01-01

    Atomic force spectroscopy is an ideal tool to study molecules at surfaces and interfaces. An experimental protocol to couple a large variety of single molecules covalently onto an AFM tip is presented. At the same time the AFM tip is passivated to prevent unspecific interactions between the tip and the substrate, which is a prerequisite to study single molecules attached to the AFM tip. Analyses to determine the adhesion force, the adhesion length, and the free energy of these molecules on solid surfaces and bio-interfaces are shortly presented and external references for further reading are provided. Example molecules are the poly(amino acid) polytyrosine, the graft polymer PI-g-PS and the phospholipid POPE (1-palmitoyl-2-oleoyl-sn-glycero-3-phosphoethanolamine). These molecules are desorbed from different surfaces like CH3-SAMs, hydrogen terminated diamond and supported lipid bilayers under various solvent conditions. Finally, the advantages of force spectroscopic single molecule experiments are discussed including means to decide if truly a single molecule has been studied in the experiment. PMID:25867282

  4. Low photon-count tip-tilt sensor

    NASA Astrophysics Data System (ADS)

    Saathof, Rudolf; Schitter, Georg

    2016-07-01

    Due to the low photon-count of dark areas of the universe, signal strength of tip-tilt sensor is low, limiting sky-coverage of reliable tip-tilt measurements. This paper presents the low photon-count tip-tilt (LPC-TT) sensor, which potentially achieves improved signal strength. Its optical design spatially samples and integrates the scene. This increases the probability that several individual sources coincide on a detector segment. Laboratory experiments show feasibility of spatial sampling and integration and the ability to measure tilt angles. By simulation an improvement of the SNR of 10 dB compared to conventional tip-tilt sensors is shown.

  5. Guidelines for development : Transportation Improvement Programs (TIPs) and the Iowa Statewide Transportation Improvement Program (STIP).

    DOT National Transportation Integrated Search

    2011-02-01

    This document serves as a reference guide to local planning agencies for the development of their regional Transportation Improvement Program (TIP) and the Statewide Transportation Improvement Program (STIP). Any questions regarding content or relati...

  6. UTILIZATION OF T-RFLP (TERMINAL RESTRICTION FRAGMENT LENGTH POLYMORPHISM) TO CHARACTERIZE MIXED ECTOMYCORRHIZAL FUNGAL COMMUNITIES

    EPA Science Inventory

    Studies of ectomycorrhizal community structure have used a variety of analytical regimens including sole or partial reliance on gross morphological characterization of colonized root tips. Depending on the rigor of the classification protocol, this technique can incorrectly assig...

  7. Application of winglets and/or wing tip extensions with active load control on the Boeing 747

    NASA Technical Reports Server (NTRS)

    Allison, R. L.; Perkin, B. R.; Schoenman, R. L.

    1978-01-01

    The application of wing tip modifications and active control technology to the Boeing 747 airplane for the purpose of improving fuel efficiency is considered. Wing tip extensions, wing tip winglets, and the use of the outboard ailerons for active wing load alleviation are described. Modest performance improvements are indicated. A costs versus benefits approach is taken to decide which, if any, of the concepts warrant further development and flight test leading to possible incorporation into production airplanes.

  8. Light Sheet Fluorescence Microscopy Quantifies Calcium Oscillations in Root Hairs of Arabidopsis thaliana.

    PubMed

    Candeo, Alessia; Doccula, Fabrizio G; Valentini, Gianluca; Bassi, Andrea; Costa, Alex

    2017-07-01

    Calcium oscillations play a role in the regulation of the development of tip-growing plant cells. Using optical microscopy, calcium oscillations have been observed in a few systems (e.g. pollen tubes, fungal hyphae and algal rhizoids). High-resolution, non-phototoxic and rapid imaging methods are required to study the calcium oscillation in root hairs. We show that light sheet fluorescence microscopy is optimal to image growing root hairs of Arabidopsis thaliana and to follow their oscillatory tip-focused calcium gradient. We describe a protocol for performing live imaging of root hairs in seedlings expressing the cytosol-localized ratiometric calcium indicator Yellow Cameleon 3.6. Using this protocol, we measured the calcium gradient in a large number of root hairs. We characterized their calcium oscillations and correlated them with the rate of hair growth. The method was then used to screen the effect of auxin on the properties of the growing root hairs. © The Author 2017. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists.

  9. Improved Temperature Dynamic Model of Turbine Subcomponents for Facilitation of Generalized Tip Clearance Control

    NASA Technical Reports Server (NTRS)

    Kypuros, Javier A.; Colson, Rodrigo; Munoz, Afredo

    2004-01-01

    This paper describes efforts conducted to improve dynamic temperature estimations of a turbine tip clearance system to facilitate design of a generalized tip clearance controller. This work builds upon research previously conducted and presented in and focuses primarily on improving dynamic temperature estimations of the primary components affecting tip clearance (i.e. the rotor, blades, and casing/shroud). The temperature profiles estimated by the previous model iteration, specifically for the rotor and blades, were found to be inaccurate and, more importantly, insufficient to facilitate controller design. Some assumptions made to facilitate the previous results were not valid, and thus improvements are presented here to better match the physical reality. As will be shown, the improved temperature sub- models, match a commercially validated model and are sufficiently simplified to aid in controller design.

  10. Effect of transjugular intrahepatic portosystemic shunt on pulmonary gas exchange in patients with portal hypertension and hepatopulmonary syndrome

    PubMed Central

    Martínez-Pallí, Graciela; Drake, Britt B; García-Pagán, Joan-Carles; Barberà, Joan-Albert; Arguedas, Miguel R; Rodriguez-Roisin, Robert; Bosch, Jaume; Fallon, Michael B

    2005-01-01

    AIM: To assess the impact of transjugular intrahepatic portosystemic shunt (TIPS) on pulmonary gas exchange and to evaluate the use of TIPS for the treatment of hepatopulmonary syndrome ( HPS ). METHODS: Seven patients, three of them with advanced HPS, in whom detailed pulmonary function tests were performed before and after TIPS placement at the University of Alabama Hospital and at the Hospital Clinic, Barcelona, were considered. RESULTS: TIPS patency was confirmed by hemodynamic evaluation. No changes in arterial blood gases were observed in the overall subset of patients. Transient arterial oxygenation improvement was observed in only one HPS patient, early after TIPS, but this was not sustained 4 mo later. CONCLUSION: TIPS neither improved nor worsened pulmonary gas exchange in patients with portal hypertension. This data does not support the use of TIPS as a specific treatment for HPS. However, it does reinforce the view that TIPS can be safely performed for the treatment of other complications of portal hypertension in patients with HPS. PMID:16425397

  11. Stark County Area Transportation Study - Transportation Improvement Program 1997-2000

    DOT National Transportation Integrated Search

    1996-05-01

    The Transportation Improvement Program (TIP) is the schedule of highway and transit improvements recommended for implementation within the next four years. It is, therefore, the end product of the transportation planning process. The TIP originates f...

  12. Endodontic Treatment of an Autogenous Transplanted Tooth Using an Er,Cr:YSGG Laser and Radial Firing Tips: Case Report.

    PubMed

    Martins, Miguel Rodrigues; Lima, Rita C; Pina-Vaz, Irene; Carvalho, Manuel Fontes; Gutknecht, Norbert

    2016-10-01

    Although several surgical techniques have been reported, no study has yet reported alternative strategies for endodontic treatment of autogenous transplanted teeth. Therefore, the aim of this clinical report is to present the long-term endodontic outcome of a nonvital autogenously transplanted third molar treated with an Er,Cr:YSGG laser and radial firing tips (RFTs). Autogenous tooth transplantation can be considered an alternative to restore edentulous areas and, in donor's teeth with complete root formation, root canal treatment should be performed up to 14 days following transplantation. In the present case report, the patient returned only after 6 months, with clinical and radiological signs of apical periodontitis (AP) associated with the transplanted tooth. Instead of traditional endodontic chemical irrigants or medications, the protocol for smear-layer removal and root canal disinfection was based on intracanal irradiation with an Er,Cr:YSGG laser and RFTs. After 3-years' follow-up, the complete reestablishment of the periodontal ligament and the arrest of the resorptive process could be noticed. This protocol has shown to be effective for the endodontic treatment of a transplanted multi-rooted tooth with AP. Further randomized clinical trials should be conducted to clearly demonstrate the effectiveness of this laser-assisted endodontic protocol.

  13. A New Method for Determining Hamaker Constants of Solids Based on the Dynamic Approach Behavior of an Atomic Force Microscope

    NASA Astrophysics Data System (ADS)

    Fronczak, Sean G.

    The Hamaker constant, A, is a quantitative measure of the fundamental attractive van der Waals (vdW) interaction for microscale and nanoscale materials. This parameter captures each material's compositional effects on the vdW force, which is often needed as input for predicting the vdW interactions between particles and surfaces. Experimental attempts to determine A using an atomic force microscope (AFM) are typically hindered by issues inherent to the cantilever-tip-surface contact regime, such as surface roughness and deformation, and contact separation distance. Thus, we developed a new method for estimating Hamaker constants from the non-contact approach regime of an AFM experiment (Fronczak et al., 2017, Langmuir 33, 714-725). This method invokes a quasi-dynamic description of the cantilever tip's approach to contact, in which the inertial effects of the tip motion are accounted for when analyzing the trajectory of the tip's approach towards the substrate. The method was tested experimentally using silica, alumina and polystyrene substrates, and was demonstrated to yield estimates of A for these materials that were in very good agreement with previously published Lifshitz calculations. As with various other approaches to determining A, our new method relies heavily on the accuracy of the geometric model used to predict the interaction between the AFM tip and the substrate. For the initial validation experiments of our new method, we therefore focused on describing the shape of the cantilever tip as closely as possible, utilizing a complex model of a truncated pyramid with a spherical cap. Although this pyramidal geometry can be confirmed and the dimensions estimated via scanning electron microscopy (SEM), even high-resolution SEM images of the tip cannot provide sufficient detail to allow precise enough determination of the tip's geometric parameters. Consequently, we also propose an adaptation of the method, in which these difficult to quantify geometric effects are still fully captured via the convenient description of the tip as an 'effective' perfect sphere. Hence, the geometric complexity of the cantilever tip is no longer explicitly required for the determination of A. First, a tip is 'calibrated', whereby the deflection at first contact between the cantilever tip and a smooth surface of known vdW properties is determined and an effective radius, Reff, of the tip is calculated. The tip's approach to contact toward other similarly smooth surfaces can then be well-described by using only this single geometric parameter. We demonstrate the practicality and accuracy of this updated method by comparing the results with both the original pyramid model and Lifshitz approximations (when available) for flat substrates composed of silica, polystyrene, highly ordered pyrolytic graphite (HOPG), sapphire (alpha-Al3O2), Plexiglas (PMMA), and acrylonitrile butadiene styrene (ABS). Then, the modified quasi-dynamic model was employed to study the strength of the adhesive interaction between TNT and several swab materials which are used as explosive detection devices at security checkpoints. This information is crucial for the development and improvement of next-generation swab detection protocols to further advance this field. Finally, we also include the effects of thermal noise into our quasi-dynamic description of the cantilever motion to better understand how such noise might influence the accuracy of our method. We likewise determine, for the first time, the effects of instrument noise on the accuracy of other approach-to-contact methodologies for determining A.

  14. Cryopreservation of in vitro grown shoot tips and apical meristems of the forage legume Arachis pintoi.

    PubMed

    Rey, Hebe Y; Faloci, Mirta; Medina, Ricardo; Dolce, Natalia; Mroginski, Luis; Engelmann, Florent

    2009-01-01

    A cryopreservation protocol using the encapsulation-dehydration procedure was established for shoot tips (2-3 mm in length) and meristems (0.3-0.5 mm) sampled from in vitro plantlets of diploid and triploid cytotypes of Arachis pintoi. The optimal protocol was the following: after dissection, explants were precultured for 24 h on establishment medium (EM), encapsulated in calcium alginate beads and pretreated in liquid EM medium with daily increasing sucrose concentration (0.5, 0.75, 1.0 M) and desiccated to 22-23 percent moisture content (fresh weight basis). Explants were frozen using slow cooling (1 C per min from 25C to -30C followed by direct immersion in liquid nitrogen), thawed rapidly and post-cultured in liquid EM medium enriched with daily decreasing sucrose concentrations (0.75, 0.50, 0.1 M). Explants were then transferred to solid EM medium in order to achieve shoot regeneration, then on Murashige and Skoog medium supplemented with 0.05 microM naphthalene acetic acid to induce rooting of shoots. With this procedure, 53 percent and 56 percent of cryopreserved shoot tips of the diploid and triploid cytotypes, respectively, survived and formed plants. However, only 16 percent of cryopreserved meristems of both cytotypes regenerated plants. Using ten isozyme systems and seven RAPD profiles, no modification induced by cryopreservation could be detected in plantlets regenerated from cryopreserved material.

  15. Chem-Braze Abradable Seal Attachment

    DTIC Science & Technology

    1980-05-01

    bonding system for attaching sintered abradable seals such as FELTMETAL® to titanium -, steel- and nickel-base compressor blade tip-shrouds has been... blade tip-shrouds was developed. The improved Chem-Braze system incorporates glycerin as an inhibitor to prevent premature evaporation which prolongs...compressor blade tip-shrouds using the improved Chem-Braze system compared to attachment with gold-nickel braze. p. p. FORM . . yn

  16. Fifteen Tips for Improving Your Grounds This Summer.

    ERIC Educational Resources Information Center

    Sturgeon, Julie

    1998-01-01

    Provides tips on how to improve a university's or college's campus grounds maintenance program that can enhance a school's appearance and improve the odds of increasing enrollment. Grass selection, tree and shrub management, and the use of flowers are examined. (GR)

  17. Use of Anti-phospho-girdin Antibodies to Visualize Intestinal Tuft Cells in Free-Floating Mouse Jejunum Cryosections

    PubMed Central

    Mizutani, Yuka; Kuga, Daisuke; Iida, Machiko; Ushida, Kaori; Takagi, Tsuyoshi; Tokita, Yoshihito; Takahashi, Masahide; Asai, Masato

    2018-01-01

    The actin binding protein girdin is a cytosolic protein that is required for actin remodeling to trigger cell migration in various tissues. Girdin is phosphorylated by both receptor and non-receptor tyrosine kinases at tyrosine 1798. Omori et al. developed site- and phosphorylation status-specific antibodies against human girdin at tyrosine-1798 (pY1798), which specifically bind to phosphorylated tyrosine-1798, but not to unphosphorylated tyrosine-1798. pY1798 antibodies have been used to specifically label tuft cells (TCs) that are present in mammalian gastrointestinal tissues, but the function of these cells is unclear. This protocol allows the robust visualization of TCs in the jejunum using pY1798 antibodies and immunofluorescence. To ensure successful and simple TC visualization, this protocol includes two histological techniques: production of free-floating cryosections from gelatin-filled jejunum tissue, and low-temperature antigen retrieval at 50 °C for 3 h. Filling the jejunum with gelatin maintains the shape of free-floating sections throughout the staining procedure, whereas low-temperature antigen retrieval ensures robust signals from TCs. Successful use of this protocol results in pY1798 staining of TCs distributed from villus tip to crypt. Stained TCs have a spool-shaped soma and fluorescent signals condense at the lumenal tip, which corresponds to the protruding 'tuft.' Phalloidin staining colocalized with pY1798-positive TCs at the thickened brush border, and corresponds to a rootlet mass extending from the TC tuft. This protocol could be used to examine TCs in human biopsy samples collected with gastrointestinal endoscopes. Furthermore, TCs were recently reported to accumulate following parasite infection in mice, suggesting that this protocol could have applications for diagnosis of parasite infections in the human gut. PMID:29630055

  18. Use of Anti-phospho-girdin Antibodies to Visualize Intestinal Tuft Cells in Free-Floating Mouse Jejunum Cryosections.

    PubMed

    Mizutani, Yuka; Kuga, Daisuke; Iida, Machiko; Ushida, Kaori; Takagi, Tsuyoshi; Tokita, Yoshihito; Takahashi, Masahide; Asai, Masato

    2018-03-21

    The actin binding protein girdin is a cytosolic protein that is required for actin remodeling to trigger cell migration in various tissues. Girdin is phosphorylated by both receptor and non-receptor tyrosine kinases at tyrosine 1798. Omori et al. developed site- and phosphorylation status-specific antibodies against human girdin at tyrosine-1798 (pY1798), which specifically bind to phosphorylated tyrosine-1798, but not to unphosphorylated tyrosine-1798. pY1798 antibodies have been used to specifically label tuft cells (TCs) that are present in mammalian gastrointestinal tissues, but the function of these cells is unclear. This protocol allows the robust visualization of TCs in the jejunum using pY1798 antibodies and immunofluorescence. To ensure successful and simple TC visualization, this protocol includes two histological techniques: production of free-floating cryosections from gelatin-filled jejunum tissue, and low-temperature antigen retrieval at 50 °C for 3 h. Filling the jejunum with gelatin maintains the shape of free-floating sections throughout the staining procedure, whereas low-temperature antigen retrieval ensures robust signals from TCs. Successful use of this protocol results in pY1798 staining of TCs distributed from villus tip to crypt. Stained TCs have a spool-shaped soma and fluorescent signals condense at the lumenal tip, which corresponds to the protruding 'tuft.' Phalloidin staining colocalized with pY1798-positive TCs at the thickened brush border, and corresponds to a rootlet mass extending from the TC tuft. This protocol could be used to examine TCs in human biopsy samples collected with gastrointestinal endoscopes. Furthermore, TCs were recently reported to accumulate following parasite infection in mice, suggesting that this protocol could have applications for diagnosis of parasite infections in the human gut.

  19. Development and testing of tip devices for horizontal axis wind turbines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gyatt, G.W.; Lissaman, P.B.S.

    1985-05-01

    A theoretical and field experimental program has been carried out to investigate the use of tip devices on horizontal axis wind turbine rotors. Objective was to improve performance by the reduction of tip losses. A vortex lattice computer model was used to optimize three basic tip configuration types for a 25 kW stall limited commercial wind turbines. The types were a change in tip planform, and a single-element and double-element nonplannar tip extension (winglets). Approximately 270 h of performance data were collected over a three-month period. The sampling interval was 2.4 s; thus over 400,000 raw data points were logged.more » Results for each of the three new tip devices, compared with the original tip, showed a small decrease (of the order of 1 kW) in power output over the measured range of wind speeds from cut-in at about 4 m/s to over 20 m/s, well into the stall limiting region. For aircraft wing tip devices, favorable tip shapes have been reported and it is likely that the tip devices tested in this program did not improve rotor performance because they were not optimally adjusted. The computer model used does not have adequate lifting surface resolution or accuracy to design these small winglet extensions.« less

  20. Polymer optical fiber compound parabolic concentrator tip for enhanced coupling efficiency for fluorescence based glucose sensors

    PubMed Central

    Hassan, Hafeez Ul; Nielsen, Kristian; Aasmul, Soren; Bang, Ole

    2015-01-01

    We demonstrate that the light excitation and capturing efficiency of fluorescence based fiber-optical sensors can be significantly increased by using a CPC (Compound Parabolic Concentrator) tip instead of the standard plane-cut tip. We use Zemax modelling to find the optimum CPC tip profile and fiber length of a polymer optical fiber diabetes sensor for continuous monitoring of glucose levels. We experimentally verify the improved performance of the CPC tipped sensor and the predicted production tolerances. Due to physical size requirements when the sensor has to be inserted into the body a non-optimal fiber length of 35 mm is chosen. For this length an average improvement in efficiency of a factor of 1.7 is experimentally demonstrated and critically compared to the predicted ideal factor of 3 in terms of parameters that should be improved through production optimization. PMID:26713213

  1. Polymer optical fiber compound parabolic concentrator tip for enhanced coupling efficiency for fluorescence based glucose sensors.

    PubMed

    Hassan, Hafeez Ul; Nielsen, Kristian; Aasmul, Soren; Bang, Ole

    2015-12-01

    We demonstrate that the light excitation and capturing efficiency of fluorescence based fiber-optical sensors can be significantly increased by using a CPC (Compound Parabolic Concentrator) tip instead of the standard plane-cut tip. We use Zemax modelling to find the optimum CPC tip profile and fiber length of a polymer optical fiber diabetes sensor for continuous monitoring of glucose levels. We experimentally verify the improved performance of the CPC tipped sensor and the predicted production tolerances. Due to physical size requirements when the sensor has to be inserted into the body a non-optimal fiber length of 35 mm is chosen. For this length an average improvement in efficiency of a factor of 1.7 is experimentally demonstrated and critically compared to the predicted ideal factor of 3 in terms of parameters that should be improved through production optimization.

  2. All-Natural Tips to Improve Your Sex Life: Exercise, Diet Changes May Help Reverse ED (Erectile Dysfunction)

    MedlinePlus

    ... your inbox ! All-natural tips to improve your sex life Exercise, diet changes may help reverse ED ... problem , may reverse your ED and improve your sex life. They are easy to adopt and enrich ...

  3. Inventive Performance Improvement of Integrated Optical Rate Sensor Using TIPS/TRIZ

    NASA Technical Reports Server (NTRS)

    Blosiu, Julian O.; Youmans, Bruce R.; Kowalick, Jim

    1996-01-01

    The Theory of Inventive Problem Solving (TIPS or also known as TRIZ) is a new scientific approach to innovative improvements of products and processes. This methodology was applied to inventively improve performance of an Integrated Optic Rate Sensor (IORS).

  4. Intramolecular bonds resolved on a semiconductor surface

    NASA Astrophysics Data System (ADS)

    Sweetman, Adam; Jarvis, Samuel P.; Rahe, Philipp; Champness, Neil R.; Kantorovich, Lev; Moriarty, Philip

    2014-10-01

    Noncontact atomic force microscopy (NC-AFM) is now routinely capable of obtaining submolecular resolution, readily resolving the carbon backbone structure of planar organic molecules adsorbed on metal substrates. Here we show that the same resolution may also be obtained for molecules adsorbed on a reactive semiconducting substrate. Surprisingly, this resolution is routinely obtained without the need for deliberate tip functionalization. Intriguingly, we observe two chemically distinct apex types capable of submolecular imaging. We characterize our tip apices by "inverse imaging" of the silicon adatoms of the Si (111)-7×7 surface and support our findings with detailed density functional theory (DFT) calculations. We also show that intramolecular resolution on individual molecules may be readily obtained at 78 K, rather than solely at 5 K as previously demonstrated. Our results suggest a wide range of tips may be capable of producing intramolecular contrast for molecules adsorbed on semiconductor surfaces, leading to a much broader applicability for submolecular imaging protocols.

  5. Development and evaluation of needle trap device geometry and packing methods for automated and manual analysis.

    PubMed

    Warren, Jamie M; Pawliszyn, Janusz

    2011-12-16

    For air/headspace analysis, needle trap devices (NTDs) are applicable for sampling a wide range of volatiles such as benzene, alkanes, and semi-volatile particulate bound compounds such as pyrene. This paper describes a new NTD that is simpler to produce and improves performance relative to previous NTD designs. A NTD utilizing a side-hole needle used a modified tip, which removed the need to use epoxy glue to hold sorbent particles inside the NTD. This design also improved the seal between the NTD and narrow neck liner of the GC injector; therefore, improving the desorption efficiency. A new packing method has been developed and evaluated using solvent to pack the device, and is compared to NTDs prepared using the previous vacuum aspiration method. The slurry packing method reduced preparation time and improved reproducibility between NTDs. To evaluate the NTDs, automated headspace extraction was completed using benzene, toluene, ethylbenzene, p-xylene (BTEX), anthracene, and pyrene (PAH). NTD geometries evaluated include: blunt tip with side-hole needle, tapered tip with side-hole needle, slider tip with side-hole, dome tapered tip with side-hole and blunt with no side-hole needle (expanded desorptive flow). Results demonstrate that the tapered and slider tip NTDs performed with improved desorption efficiency. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Influence of blade tip rounding on tip leakage vortex cavitation of axial flow pump

    NASA Astrophysics Data System (ADS)

    Wu, S. Q.; Shi, W. D.; Zhang, D. S.; Yao, J.; Cheng, C.

    2013-12-01

    Tip leakage flow in axial flow pumps is mainly caused by the tip clearance, which is the main cause of tip leakage vortex cavitation and blade tip cavitation erosion. In order to improve tip clearance flow and reduce TLV cavitation, four schemes were adopted to the round blade tip. These are: no tip rounding, one time tip clearance tip rounding, two times tip clearance tip rounding, four times tip clearance tip rounding. Using SST k-ω turbulence model and Zwart cavitation model in CFX software, this simulation obtained four kinds of inner flow field results. The numerical results indicated that with the increase of r*, NPSHc gradually increased and the cavitation performance reduced. However, corner vortex was eliminated so that cavitation in gap was restrained. But TLV vorticity increased and cavitation's range here had a little expansion. Combined with the research of this paper and the different analyses of four schemes, we recommend adopting the two times of the tip clearance rounding.

  7. High-loading low-speed fan study. 4: Data and performance with redesign stator and including a rotor tip casing treatment

    NASA Technical Reports Server (NTRS)

    Harley, K. G.; Odegard, P. A.; Burdsall, E. A.

    1972-01-01

    A single stage fan with a rotor tip speed of 1000 ft/sec(304.8 m/sec) and a hub-to-tip ratio of 0.392 was retested with a redesigned stator. Tests were conducted with uniform inlet, tip-radial, hub-radial, and circumferential inlet distortions. With uniform inlet flow, stall margin was improved 12 percentage points above that with the original stator. The fan demonstrated an efficiency of 0.883 and a stall margin of 15 percent at a pressure ratio of 1.488 and a specific flow of 41.17 lb/sec/sq ft. Tests were also made with a redesigned casing treatment consisting of skewed slots over the rotor blade tips. This casing treatment gave a 7 percentage point improvement in stall margin when tested with tip radial distortion (when the rotor tip initiated stall). Noise measurements at the fan inlet and exit indicate no effect from closing the stator 10 degrees, nor were there measurable effects from adding skewed slots over the blade tips.

  8. Theoretical study of carbon-based tips for scanning tunnelling microscopy.

    PubMed

    González, C; Abad, E; Dappe, Y J; Cuevas, J C

    2016-03-11

    Motivated by recent experiments, we present here a detailed theoretical analysis of the use of carbon-based conductive tips in scanning tunnelling microscopy. In particular, we employ ab initio methods based on density functional theory to explore a graphitic, an amorphous carbon and two diamond-like tips for imaging with a scanning tunnelling microscope (STM), and we compare them with standard metallic tips made of gold and tungsten. We investigate the performance of these tips in terms of the corrugation of the STM images acquired when scanning a single graphene sheet. Moreover, we analyse the impact of the tip-sample distance and show that it plays a fundamental role in the resolution and symmetry of the STM images. We also explore in depth how the adsorption of single atoms and molecules in the tip apexes modifies the STM images and demonstrate that, in general, it leads to an improved image resolution. The ensemble of our results provides strong evidence that carbon-based tips can significantly improve the resolution of STM images, as compared to more standard metallic tips, which may open a new line of research in scanning tunnelling microscopy.

  9. LONG-TERM PRECONDITIONING OF PLANTLETS: A PRACTICAL METHOD FOR ENHANCING SURVIVAL OF PINEAPPLE (Ananas comosus Merr.) SHOOT TIPS CRYOPRESERVED USING VITRIFICATION.

    PubMed

    Hu, W H; Liu, S F; Liaw, S I

    2015-01-01

    The purpose of this study was to develop an efficient cryopreservation protocol for pineapple (Ananas comosus Merr.) shoot tips. The optimal state of pineapple plantlets was investigated by using sucrose preconditioning to enhance survival after cryostorage. To achieve a suitable state of plantlets before cryopreservation, 0.2 M to 0.4 M sucrose concentrations combined with short- (0-7 days), medium- (15-30 days), and long-term (75-150 days) preconditioning periods were compared. The highest survival (100 %) was achieved using the following procedure: intact plantlets underwent long-term preconditioning with 0.2 M sucrose for 135 days, dissected shoot tips were treated with a loading solution containing 2.0 M glycerol + 0.4 M sucrose for 60 min at 25 degree and the shoot tips were dehydrated in PVS2 for 2h at 0 degree C before being plunged in liquid nitrogen. Rewarming was conducted in a water-bath for 30 s at 40 degree C and PVS2 was replaced with a 1.2 M sucrose solution for 30 min at 25 degree C. The shoot tips were transferred on semisolid medium and left in the dark for 1 week, then in dim light for 3 weeks.

  10. Tip-enhanced Raman scattering microscopy: Recent advance in tip production

    NASA Astrophysics Data System (ADS)

    Fujita, Yasuhiko; Walke, Peter; De Feyter, Steven; Uji-i, Hiroshi

    2016-08-01

    Tip-enhanced Raman scattering (TERS) microscopy is a technique that combines the chemical sensitivity of Raman spectroscopy with the resolving power of scanning probe microscopy. The key component of any TERS setup is a plasmonically-active noble metal tip, which serves to couple far-field incident radiation with the near-field. Thus, the design and implementation of reproducible probes are crucial for the continued development of TERS as a tool for nanoscopic analysis. Here we discuss conventional methods for the fabrication of TERS-ready tips, highlighting the problems therein, as well as detailing more recent developments to improve reducibility. In addition, the idea of remote excitation-TERS is enlightened upon, whereby TERS sensitivity is further improved by using propagating surface plasmons to separate the incident radiation from the tip apex, as well as how this can be incorporated into the fabrication process.

  11. 100 Consejos para los Padres (100 Tips for Parents).

    ERIC Educational Resources Information Center

    Department of Education, Washington, DC.

    Noting that involved parents can improve their children's chances of succeeding in school, this packet of Spanish-language cards offers 100 tips created to help parents become more involved in their child's education. Following a card of general tips on becoming involved, tips are offered in the following topic areas: keeping a child alcohol,…

  12. Identification of a highly successful cryopreservation method (droplet-vitrification) for petunia

    USDA-ARS?s Scientific Manuscript database

    Petunia (Petunia × hybrida Vilm.) is a very important crop conserved in the National Genebank of China. Petunia cultivar “Niu 2” was used to develop a droplet-vitrification protocol to cryopreserve shoot tips. Six variables (age of the in vitro plants, concentration of sucrose in the preculture solu...

  13. Hot Tips for Teachers. Staff Development Series. [Videotape].

    ERIC Educational Resources Information Center

    TV Ontario, Toronto.

    This 15-minute videotape offers a motivational staff development program for teachers. Four segments focus on: (1) preparing for the teacher's absence (e.g., knowing the school's policy and protocol, preparing a safety kit for the substitute teacher, and keeping a box of learning materials available for the substitute); (2) effective learning…

  14. Understanding and Mitigating Tip Leakage and Endwall Losses in High Pressure Ratio Cores

    NASA Technical Reports Server (NTRS)

    Christophel, Jesse

    2015-01-01

    Reducing endwall and tip secondary flow losses will be a key enabler for the next generation of commercial and military air transport and will be an improvement on the state-of-the-art in turbine loss reduction strategies. The objective of this research is three-fold: 1) To improve understanding of endwall secondary flow and tip clearance losses 2) To develop novel technologies to mitigate these losses and test them in low-speed cascade and rig environments 3) To validate predictive tools To accomplish these objectives, Pratt & Whitney (P&W) has teamed with Pennsylvania State University (PSU) to experimentally test new features designed by P&W. P&W will create new rim-cavity features to reduce secondary flow loss and improve purge flow cooling effectiveness and new blade tip features to manage leakage flows and reduce tip leakage secondary flow loss. P&W is currently developing technologies in these two areas that expect to be assimilated in the N+2/N+3 generation of commercial engines.

  15. Trials of Improved Practices (TIPs): A Strategy for Making Long-Lasting Nets Last Longer?

    PubMed Central

    Harvey, Steven A.; Paredes Olórtegui, Maribel; Leontsini, Elli; Ramal Asayag, César; Scott, Kerry; Winch, Peter J.

    2013-01-01

    Long-lasting insecticidal net (LLIN) use is a proven malaria prevention method. Mass distribution has greatly expanded LLIN access in sub-Saharan Africa, but a gap remains between LLIN ownership and use. Furthermore, LLINs wear out more quickly than anticipated. This paper suggests a participatory research strategy—trials of improved practices (TIPs)—that could identify locally appropriate approaches to prolonging net life and increasing effective use. We used TIPs to overcome barriers to optimal net use in the Peruvian Amazon. Working with 15 families in three villages, we tested home treatment of cotton nets, use of an alternative netting fabric, and alternative washing and care instructions. TIPs helped confirm feasibility of these interventions. Although our findings are time- and context-specific, TIPs could help improve consistency and effectiveness of current LLIN use and prolong net lifespan in sub-Saharan Africa and elsewhere. This would help maximize the value of shrinking donor resources for malaria. PMID:23530074

  16. 'On Your Feet to Earn Your Seat', a habit-based intervention to reduce sedentary behaviour in older adults: study protocol for a randomized controlled trial.

    PubMed

    Gardner, Benjamin; Thuné-Boyle, Ingela; Iliffe, Steve; Fox, Kenneth R; Jefferis, Barbara J; Hamer, Mark; Tyler, Nick; Wardle, Jane

    2014-09-20

    Many older adults are both highly sedentary (that is, spend considerable amounts of time sitting) and physically inactive (that is, do little physical activity). This protocol describes an exploratory trial of a theory-based behaviour change intervention in the form of a booklet outlining simple activities ('tips') designed both to reduce sedentary behaviour and to increase physical activity in older adults. The intervention is based on the 'habit formation' model, which proposes that consistent repetition leads to behaviour becoming automatic, sustaining activity gains over time. The intervention is being developed iteratively, in line with Medical Research Council complex intervention guidelines. Selection of activity tips was informed by semi-structured interviews and focus groups with older adults, and input from a multidisciplinary expert panel. An ongoing preliminary field test of acceptability among 25 older adults will inform further refinement. An exploratory randomized controlled trial will be conducted within a primary care setting, comparing the tips booklet with a control fact sheet. Retired, inactive and sedentary adults (n = 120) aged 60 to 74 years, with no physical impairments precluding light physical activity, will be recruited from general practices in north London, UK. The primary outcomes are recruitment and attrition rates. Secondary outcomes are changes in behaviour, habit, health and wellbeing over 12 weeks. Data will be used to inform study procedures for a future, larger-scale definitive randomized controlled trial. Current Controlled Trials ISRCTN47901994.

  17. Advanced and innovative wind energy concept development: Dynamic inducer system, executive summary

    NASA Astrophysics Data System (ADS)

    Lissaman, P. B. S.; Zalay, A. D.; Hibbs, B. H.

    1981-05-01

    Concepts to improve the technical and economic performance of wind energy conversion systems (WECS) were examined. One technique for improving the cost-effectiveness of WECS is the use of tip vanes. Tip vanes are small airfoils attached approximately at right angles to the rotor tips with their span oriented approximately parallel to the local freestream. The performance benefits of the dynamic inducer tip vane system were demonstrated Tow-tests conducted on a three-bladed, 3.6-meter diameter rotor show that a dynamic inducer can achieve a power coefficient of 0.5, which exceeds that of a plain rotor by about 35%.

  18. Reasons for low aerodynamic performance of 13.5-centimeter-tip-diameter aircraft engine starter turbine

    NASA Technical Reports Server (NTRS)

    Haas, J. E.; Roelke, R. J.; Hermann, P.

    1981-01-01

    The reasons for the low aerodynamic performance of a 13.5 cm tip diameter aircraft engine starter turbine were investigated. Both the stator and the stage were evaluated. Approximately 10 percent improvement in turbine efficiency was obtained when the honeycomb shroud over the rotor blade tips was filled to obtain a solid shroud surface. Efficiency improvements were obtained for three rotor configurations when the shroud was filled. It is suggested that the large loss associated with the open honeycomb shroud is due primarily to energy loss associated with gas transportation as a result of the blade to blade pressure differential at the tip section.

  19. Scanning tip microwave near field microscope

    DOEpatents

    Xiang, X.D.; Schultz, P.G.; Wei, T.

    1998-10-13

    A microwave near field microscope has a novel microwave probe structure wherein the probing field of evanescent radiation is emitted from a sharpened metal tip instead of an aperture or gap. This sharpened tip, which is electrically and mechanically connected to a central electrode, extends through and beyond an aperture in an end wall of a microwave resonating device such as a microwave cavity resonator or a microwave stripline resonator. Since the field intensity at the tip increases as the tip sharpens, the total energy which is radiated from the tip and absorbed by the sample increases as the tip sharpens. The result is improved spatial resolution without sacrificing sensitivity. 17 figs.

  20. Scanning tip microwave near field microscope

    DOEpatents

    Xiang, Xiao-Dong; Schultz, Peter G.; Wei, Tao

    1998-01-01

    A microwave near field microscope has a novel microwave probe structure wherein the probing field of evanescent radiation is emitted from a sharpened metal tip instead of an aperture or gap. This sharpened tip, which is electrically and mechanically connected to a central electrode, extends through and beyond an aperture in an endwall of a microwave resonating device such as a microwave cavity resonator or a microwave stripline resonator. Since the field intensity at the tip increases as the tip sharpens, the total energy which is radiated from the tip and absorbed by the sample increases as the tip sharpens. The result is improved spatial resolution without sacrificing sensitivity.

  1. Going Vertical To Improve the Accuracy of Atomic Force Microscopy Based Single-Molecule Force Spectroscopy.

    PubMed

    Walder, Robert; Van Patten, William J; Adhikari, Ayush; Perkins, Thomas T

    2018-01-23

    Single-molecule force spectroscopy (SMFS) is a powerful technique to characterize the energy landscape of individual proteins, the mechanical properties of nucleic acids, and the strength of receptor-ligand interactions. Atomic force microscopy (AFM)-based SMFS benefits from ongoing progress in improving the precision and stability of cantilevers and the AFM itself. Underappreciated is that the accuracy of such AFM studies remains hindered by inadvertently stretching molecules at an angle while measuring only the vertical component of the force and extension, degrading both measurements. This inaccuracy is particularly problematic in AFM studies using double-stranded DNA and RNA due to their large persistence length (p ≈ 50 nm), often limiting such studies to other SMFS platforms (e.g., custom-built optical and magnetic tweezers). Here, we developed an automated algorithm that aligns the AFM tip above the DNA's attachment point to a coverslip. Importantly, this algorithm was performed at low force (10-20 pN) and relatively fast (15-25 s), preserving the connection between the tip and the target molecule. Our data revealed large uncorrected lateral offsets for 100 and 650 nm DNA molecules [24 ± 18 nm (mean ± standard deviation) and 180 ± 110 nm, respectively]. Correcting this offset yielded a 3-fold improvement in accuracy and precision when characterizing DNA's overstretching transition. We also demonstrated high throughput by acquiring 88 geometrically corrected force-extension curves of a single individual 100 nm DNA molecule in ∼40 min and versatility by aligning polyprotein- and PEG-based protein-ligand assays. Importantly, our software-based algorithm was implemented on a commercial AFM, so it can be broadly adopted. More generally, this work illustrates how to enhance AFM-based SMFS by developing more sophisticated data-acquisition protocols.

  2. Differential effects of tactile high- and low-frequency stimulation on tactile discrimination in human subjects.

    PubMed

    Ragert, Patrick; Kalisch, Tobias; Bliem, Barbara; Franzkowiak, Stephanie; Dinse, Hubert R

    2008-01-23

    Long-term potentiation (LTP) and long-term depression (LTD) play important roles in mediating activity-dependent changes in synaptic transmission and are believed to be crucial mechanisms underlying learning and cortical plasticity. In human subjects, however, the lack of adequate input stimuli for the induction of LTP and LTD makes it difficult to study directly the impact of such protocols on behavior. Using tactile high- and low-frequency stimulation protocols in humans, we explored the potential of such protocols for the induction of perceptual changes. We delivered tactile high-frequency and low-frequency stimuli (t-HFS, t-LFS) to skin sites of approximately 50 mm2 on the tip of the index finger. As assessed by 2-point discrimination, we demonstrate that 20 minutes of t-HFS improved tactile discrimination, while t-LFS impaired performance. T-HFS-effects were stable for at least 24 hours whereas t-LFS-induced changes recovered faster. While t-HFS changes were spatially very specific with no changes on the neighboring fingers, impaired tactile performance after t-LFS was also observed on the right middle-finger. A central finding was that for both t-LFS and t-HFS perceptual changes were dependent on the size of the stimulated skin area. No changes were observed when the stimulated area was very small (< 1 mm2) indicating special requirements for spatial summation. Our results demonstrate differential effects of such protocols in a frequency specific manner that might be related to LTP- and LTD-like changes in human subjects.

  3. Virtual reality visual feedback for hand-controlled scanning probe microscopy manipulation of single molecules.

    PubMed

    Leinen, Philipp; Green, Matthew F B; Esat, Taner; Wagner, Christian; Tautz, F Stefan; Temirov, Ruslan

    2015-01-01

    Controlled manipulation of single molecules is an important step towards the fabrication of single molecule devices and nanoscale molecular machines. Currently, scanning probe microscopy (SPM) is the only technique that facilitates direct imaging and manipulations of nanometer-sized molecular compounds on surfaces. The technique of hand-controlled manipulation (HCM) introduced recently in Beilstein J. Nanotechnol. 2014, 5, 1926-1932 simplifies the identification of successful manipulation protocols in situations when the interaction pattern of the manipulated molecule with its environment is not fully known. Here we present a further technical development that substantially improves the effectiveness of HCM. By adding Oculus Rift virtual reality goggles to our HCM set-up we provide the experimentalist with 3D visual feedback that displays the currently executed trajectory and the position of the SPM tip during manipulation in real time, while simultaneously plotting the experimentally measured frequency shift (Δf) of the non-contact atomic force microscope (NC-AFM) tuning fork sensor as well as the magnitude of the electric current (I) flowing between the tip and the surface. The advantages of the set-up are demonstrated by applying it to the model problem of the extraction of an individual PTCDA molecule from its hydrogen-bonded monolayer grown on Ag(111) surface.

  4. Biodegradable 3D printed polymer microneedles for transdermal drug delivery.

    PubMed

    Luzuriaga, Michael A; Berry, Danielle R; Reagan, John C; Smaldone, Ronald A; Gassensmith, Jeremiah J

    2018-04-17

    Biodegradable polymer microneedle (MN) arrays are an emerging class of transdermal drug delivery devices that promise a painless and sanitary alternative to syringes; however, prototyping bespoke needle architectures is expensive and requires production of new master templates. Here, we present a new microfabrication technique for MNs using fused deposition modeling (FDM) 3D printing using polylactic acid, an FDA approved, renewable, biodegradable, thermoplastic material. We show how this natural degradability can be exploited to overcome a key challenge of FDM 3D printing, in particular the low resolution of these printers. We improved the feature size of the printed parts significantly by developing a post fabrication chemical etching protocol, which allowed us to access tip sizes as small as 1 μm. With 3D modeling software, various MN shapes were designed and printed rapidly with custom needle density, length, and shape. Scanning electron microscopy confirmed that our method resulted in needle tip sizes in the range of 1-55 μm, which could successfully penetrate and break off into porcine skin. We have also shown that these MNs have comparable mechanical strengths to currently fabricated MNs and we further demonstrated how the swellability of PLA can be exploited to load small molecule drugs and how its degradability in skin can release those small molecules over time.

  5. Advanced turbine blade tip seal system

    NASA Technical Reports Server (NTRS)

    Zelahy, J. W.

    1981-01-01

    An advanced blade/shroud system designed to maintain close clearance between blade tips and turbine shrouds and at the same time, be resistant to environmental effects including high temperature oxidation, hot corrosion, and thermal cycling is described. Increased efficiency and increased blade life are attained by using the advanced blade tip seal system. Features of the system include improved clearance control when blade tips preferentially wear the shrouds and a superior single crystal superalloy tip. The tip design, joint location, characterization of the single crystal tip alloy, the abrasive tip treatment, and the component and engine test are among the factors addressed. Results of wear testing, quality control plans, and the total manufacturing cycle required to fully process the blades are also discussed.

  6. Tips pentacene crystal alignment for improving performance of solution processed organic thin film transistors

    NASA Astrophysics Data System (ADS)

    He, Zhengran

    A newly-developed p-type organic semiconductor 6,13-bis (triisopropylsilylethynyl) pentacene (TIPS pentacene) demonstrates various advantages such as high mobility, air stability and solution processibility, but at the same time its application is restricted by major issues, such as crystal misorientation and performance variation of organic thin-film transistors (OTFTs). This dissertation demonstrates several different approaches to address these issues. As a result, both crystal orientation and areal coverage can be effectively improved, leading to an enhancement of average mobility and performance consistency of OTFTs. Chapter 1 presents an introduction and background of this dissertation. Chapter 2 explores the usage of inorganic silica nanoparticles to manipulate the morphology of TIPS pentacene thin films and the performance of solution-processed organic OTFTs. The resultant drop-cast films yield improved morphological uniformity at ~10% SiO2 loading, which also leads to a 3-fold increase in average mobility and nearly 4-times reduction in the ratio of standard deviation of mobility (μStdev) to average mobility (μAvg). The experimental results suggest that the SiO2 nanoparticles mostly aggregate at TIPS pentacene grain boundaries, and that 10% nanoparticle concentration effectively reduces the undesirable crystal misorientation without considerably compromising TIPS pentacene crystallinity. Chapter 3 discusses the utilization of air flow to effectively reduce the TIPS pentacene crystal anisotropy and enhance performance consistency in OTFTs. Under air-flow navigation (AFN), TIPS pentacene forms thin films with improved crystal orientation and increased areal coverage, which subsequently lead to a four-fold increase of average hole mobility and one order of magnitude enhancement in performance consistency. Chapter 4 investigates the critical roles of lateral and vertical phase separation in the performance of the next-generation organic and hybrid electronic devices. A novel method is demonstrated here to switch between lateral and vertical phase separation in semiconducting TIPS pentacene/ polymer blend films by simply varying the alkyl length of the polyacrylate polymer component. The phase separation modes depend on intermolecular interactions between small molecule TIPS pentacene and polymer additives. The blend film with a dominant vertical phase separation exhibits a significant enhancement in average mobility and performance consistency of organic OTFTs. Chapter 5 demonstrates an effective approach to improve both charge transport and performance consistency in solution-processed OTFTs by blending TIPS pentacene with a series of small-molecule additives: 4-butylbenzoic acid (BBA), 4-hexylbenzoic acid (HBA), and 4-octylbenzoic acid (OBA). These three small molecules share a benzoic acid moiety, but have different length of hydrophobic tails. The self-assembled interfacial layer of small molecules on the gate oxide surface leads to uniform deposition of TIPS pentacene crystal seeds and facilitates TIPS pentacene to grow along the tilted orientation of substrate, which results in a film of enhanced crystal orientation and areal coverage. OTFTs based on TIPS pentacene/small molecule blends demonstrate greatly improved average hole mobility and performance consistency, which correlates with the length of hydrophobic tail of the small-molecule additives. Chapter 6 summarizes the conclusions of this dissertation and the related future work.

  7. Two-stage fan. 3: Data and performance with rotor tip casing treatment, uniform and distorted inlet flows

    NASA Technical Reports Server (NTRS)

    Burger, G. D.; Hodges, T. R.; Keenan, M. J.

    1975-01-01

    A two stage fan with a 1st-stage rotor design tip speed of 1450 ft/sec, a design pressure ratio of 2.8, and corrected flow of 184.2 lbm/sec was tested with axial skewed slots in the casings over the tips of both rotors. The variable stagger stators were set in the nominal positions. Casing treatment improved stall margin by nine percentage points at 70 percent speed but decreased stall margin, efficiency, and flow by small amounts at design speed. Treatment improved first stage performance at low speed only and decreased second stage performance at all operating conditions. Casing treatment did not affect the stall line with tip radially distorted flow but improved stall margin with circumferentially distorted flow. Casing treatment increased the attenuation for both types of inlet flow distortion.

  8. Hover and Wind-Tunnel Testing of Shrouded Rotors for Improved Micro Air Vehicle Design

    DTIC Science & Technology

    2008-01-01

    and the shroud surface pressure distributions. The uniformity of the wake was improved by the presence of the shrouds and by decreasing the blade tip...213 3.35 Effect of blade tip clearance on shrouded-rotor exit-plane wake profiles215 3.36 Effects of changing blade tip clearance on induced...Wright [139] developed a vortex wake model for heavily loaded ducted fans, in which the “inner vortex sheets [shed from the blades ] move at a different

  9. Endovascular Catheter for Magnetic Navigation under MR Imaging Guidance: Evaluation of Safety in Vivo at 1.5T

    PubMed Central

    Hetts, S.W.; Saeed, M.; Martin, A.J.; Evans, L.; Bernhardt, A.F.; Malba, V.; Settecase, F.; Do, L.; Yee, E.J.; Losey, A.; Sincic, R.; Roy, S.; Arenson, R.L.; Wilson, M.W.

    2013-01-01

    BACKGROUND AND PURPOSE: Endovascular navigation under MR imaging guidance can be facilitated by a catheter with steerable microcoils on the tip. Not only do microcoils create visible artifacts allowing catheter tracking, but also they create a small magnetic moment permitting remote-controlled catheter tip deflection. A side product of catheter tip electrical currents, however, is the heat that might damage blood vessels. We sought to determine the upper boundary of electrical currents safely usable at 1.5T in a coil-tipped microcatheter system. MATERIALS AND METHODS: Alumina tubes with solenoid copper coils were attached to neurovascular microcatheters with heat shrink-wrap. Catheters were tested in carotid arteries of 8 pigs. The catheters were advanced under x-ray fluoroscopy and MR imaging. Currents from 0 mA to 700 mA were applied to test heating and potential vascular damage. Postmortem histologic analysis was the primary endpoint. RESULTS: Several heat-mitigation strategies demonstrated negligible vascular damage compared with control arteries. Coil currents ≤300 mA resulted in no damage (0/58 samples) compared with 9 (25%) of 36 samples for > 300-mA activations (P = .0001). Tip coil activation ≤1 minute and a proximal carotid guide catheter saline drip > 2 mL/minute also had a nonsignificantly lower likelihood of vascular damage. For catheter tip coil activations ≤300 mA for ≤1 minute in normal carotid flow, 0 of 43 samples had tissue damage. CONCLUSIONS: Activations of copper coils at the tip of microcatheters at low currents in 1.5T MR scanners can be achieved without significant damage to blood vessel walls in a controlled experimental setting. Further optimization of catheter design and procedure protocols is necessary for safe remote control magnetic catheter guidance. PMID:23846795

  10. Sea trials of a ducted tip propeller designed for improved cavitation performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hordnes, I.; Bidaud, A.; Green, S.I.

    1994-12-31

    Studies have shown that ``ring-wing`` or ``ducted`` tip devices reduce substantially the inception index of trailing vortices generated by a hydrofoil (Green et al. 1988). It has also been shown that these devices improve the lift/drag ratio of an airfoil at high angle of incidence (Duan et al. 1992). These finding indicate that there may be a marine application for the ducted tip. Experimental equipment has been designed and manufactured in preparation for upcoming tests of a propeller with ducted tips. The tips are tubes aligned with the propeller blade tips that will replace a radial fraction of the originalmore » blade tips equal to the diameter of the tubes. The tube dimensions have been chosen according to the span/tip diameter and chord/tip length ratios used by Duan et al. (1992), and the tubes will be given a curvature equal to the propeller tip radius. Field trials will be given a curvature equal to the propeller tip radius. Field trials will be conducted on a 36 inch diameter propeller that is used to propel a 45 ft. fishing (seine) boat operating in the coastal waters outside Vancouver. The performance of the propeller will be measured in terms of the propeller efficiency as a function of advance ratio. A special force transducer has been designed that is capable of recording both torque and thrust on the propeller shaft even though these are expected to produce shaft strains of different orders of magnitude. As a supplementary means of monitoring the propeller performance, a hydrophone will be located near the propeller wake in order to measure the tip vortex cavitation noise.« less

  11. Forensic DNA typing from teeth using demineralized root tips.

    PubMed

    Corrêa, Heitor Simões Dutra; Pedro, Fabio Luis Miranda; Volpato, Luiz Evaristo Ricci; Pereira, Thiago Machado; Siebert Filho, Gilberto; Borges, Álvaro Henrique

    2017-11-01

    Teeth are widely used samples in forensic human genetic identification due to their persistence and practical sampling and processing. Their processing, however, has changed very little in the last 20 years, usually including powdering or pulverization of the tooth. The objective of this study was to present demineralized root tips as DNA sources while, at the same time, not involving powdering the samples or expensive equipment for teeth processing. One to five teeth from each of 20 unidentified human bodies recovered from midwest Brazil were analyzed. Whole teeth were demineralized in EDTA solution with daily solution change. After a maximum of approximately seven days, the final millimeters of the root tip was excised. This portion of the sample was used for DNA extraction through a conventional organic protocol. DNA quantification and STR amplification were performed using commercial kits followed by capillary electrophoresis on 3130 or 3500 genetic analyzers. For 60% of the unidentified bodies (12 of 20), a full genetic profile was obtained from the extraction of the first root tip. By the end of the analyses, full genetic profiles were obtained for 85% of the individuals studied, of which 80% were positively identified. This alternative low-tech approach for postmortem teeth processing is capable of extracting DNA in sufficient quantity and quality for forensic casework, showing that root tips are viable nuclear DNA sources even after demineralization. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Predicting mountain lion activity using radiocollars equipped with mercury tip-sensors

    USGS Publications Warehouse

    Janis, Michael W.; Clark, Joseph D.; Johnson, Craig

    1999-01-01

    Radiotelemetry collars with tip-sensors have long been used to monitor wildlife activity. However, comparatively few researchers have tested the reliability of the technique on the species being studied. To evaluate the efficacy of using tip-sensors to assess mountain lion (Puma concolor) activity, we radiocollared 2 hand-reared mountain lions and simultaneously recorded their behavior and the associated telemetry signal characteristics. We noted both the number of pulse-rate changes and the percentage of time the transmitter emitted a fast pulse rate (i.e., head up) within sampling intervals ranging from 1-5 minutes. Based on 27 hours of observations, we were able to correctly distinguish between active and inactive behaviors >93% of the time using a logistic regression model. We present several models to predict activity of mountain lions; the selection of which to us would depend on study objectives and logistics. Our results indicate that field protocols that use only pulse-rate changes to indicate activity can lead to significant classification errors.

  13. Large-Scale Fabrication of Carbon Nanotube Probe Tips For Atomic Force Microscopy Critical Dimension Imaging Applications

    NASA Technical Reports Server (NTRS)

    Ye, Qi Laura; Cassell, Alan M.; Stevens, Ramsey M.; Meyyappan, Meyya; Li, Jun; Han, Jie; Liu, Hongbing; Chao, Gordon

    2004-01-01

    Carbon nanotube (CNT) probe tips for atomic force microscopy (AFM) offer several advantages over Si/Si3N4 probe tips, including improved resolution, shape, and mechanical properties. This viewgraph presentation discusses these advantages, and the drawbacks of existing methods for fabricating CNT probe tips for AFM. The presentation introduces a bottom up wafer scale fabrication method for CNT probe tips which integrates catalyst nanopatterning and nanomaterials synthesis with traditional silicon cantilever microfabrication technology. This method makes mass production of CNT AFM probe tips feasible, and can be applied to the fabrication of other nanodevices with CNT elements.

  14. Impact of distal median neuropathy on handwriting performance for patients with carpal tunnel syndrome in office and administrative support occupations.

    PubMed

    Kuo, Li-Chieh; Hsu, Hsiao-Man; Wu, Po-Ting; Lin, Sheng-Che; Hsu, Hsiu-Yun; Jou, I-Ming

    2014-06-01

    This study investigates the handwriting performance of patients with carpal tunnel syndrome (CTS) and healthy controls in office and administrative support occupations, adopting both biomechanical and functional perspectives. This work also explores how surgical intervention altered the performance of the CTS patients. Fourteen CTS patients and 14 control subjects were recruited to complete a self-reported survey and participate in sensory tests, hand strength, dexterity and handwriting tasks using a custom force acquisition pen along with motion capture technology. Based on the results of these, the sensory measurements, along with functional and biomechanical parameters, were used to determine the differences between the groups and also reveal any improvements that occurred in the CTS group after surgical intervention. The CTS patients showed significantly poorer hand sensibility and dexterity than the controls, as well as excessive force exertion of the digits and pen tip, and less efficient force adjustment ability during handwriting. After surgery and sensory recovery, the hand dexterity and pen tip force of the CTS patients improved significantly. The force adjustment abilities of the digits also increased, but these changes were not statistically significant. This study provides the objective measurements and novel apparatus that can be used to determine impairments in the handwriting abilities of office or administrative workers with CTS. The results can also help clinicians or patients to better understand the sensory-related deficits in sensorimotor control of the hand related to CTS, and thus develop and implement more suitable training or adaptive protocols.

  15. Cell population structure prior to bifurcation predicts efficiency of directed differentiation in human induced pluripotent cells

    PubMed Central

    Bargaje, Rhishikesh; Trachana, Kalliopi; Shelton, Martin N.; McGinnis, Christopher S.; Zhou, Joseph X.; Chadick, Cora; Cook, Savannah; Cavanaugh, Christopher; Huang, Sui; Hood, Leroy

    2017-01-01

    Steering the differentiation of induced pluripotent stem cells (iPSCs) toward specific cell types is crucial for patient-specific disease modeling and drug testing. This effort requires the capacity to predict and control when and how multipotent progenitor cells commit to the desired cell fate. Cell fate commitment represents a critical state transition or “tipping point” at which complex systems undergo a sudden qualitative shift. To characterize such transitions during iPSC to cardiomyocyte differentiation, we analyzed the gene expression patterns of 96 developmental genes at single-cell resolution. We identified a bifurcation event early in the trajectory when a primitive streak-like cell population segregated into the mesodermal and endodermal lineages. Before this branching point, we could detect the signature of an imminent critical transition: increase in cell heterogeneity and coordination of gene expression. Correlation analysis of gene expression profiles at the tipping point indicates transcription factors that drive the state transition toward each alternative cell fate and their relationships with specific phenotypic readouts. The latter helps us to facilitate small molecule screening for differentiation efficiency. To this end, we set up an analysis of cell population structure at the tipping point after systematic variation of the protocol to bias the differentiation toward mesodermal or endodermal cell lineage. We were able to predict the proportion of cardiomyocytes many days before cells manifest the differentiated phenotype. The analysis of cell populations undergoing a critical state transition thus affords a tool to forecast cell fate outcomes and can be used to optimize differentiation protocols to obtain desired cell populations. PMID:28167799

  16. Cell population structure prior to bifurcation predicts efficiency of directed differentiation in human induced pluripotent cells.

    PubMed

    Bargaje, Rhishikesh; Trachana, Kalliopi; Shelton, Martin N; McGinnis, Christopher S; Zhou, Joseph X; Chadick, Cora; Cook, Savannah; Cavanaugh, Christopher; Huang, Sui; Hood, Leroy

    2017-02-28

    Steering the differentiation of induced pluripotent stem cells (iPSCs) toward specific cell types is crucial for patient-specific disease modeling and drug testing. This effort requires the capacity to predict and control when and how multipotent progenitor cells commit to the desired cell fate. Cell fate commitment represents a critical state transition or "tipping point" at which complex systems undergo a sudden qualitative shift. To characterize such transitions during iPSC to cardiomyocyte differentiation, we analyzed the gene expression patterns of 96 developmental genes at single-cell resolution. We identified a bifurcation event early in the trajectory when a primitive streak-like cell population segregated into the mesodermal and endodermal lineages. Before this branching point, we could detect the signature of an imminent critical transition: increase in cell heterogeneity and coordination of gene expression. Correlation analysis of gene expression profiles at the tipping point indicates transcription factors that drive the state transition toward each alternative cell fate and their relationships with specific phenotypic readouts. The latter helps us to facilitate small molecule screening for differentiation efficiency. To this end, we set up an analysis of cell population structure at the tipping point after systematic variation of the protocol to bias the differentiation toward mesodermal or endodermal cell lineage. We were able to predict the proportion of cardiomyocytes many days before cells manifest the differentiated phenotype. The analysis of cell populations undergoing a critical state transition thus affords a tool to forecast cell fate outcomes and can be used to optimize differentiation protocols to obtain desired cell populations.

  17. Histological characterization of Passiflora pohlii Mast. root tips cryopreserved using the V-Cryo-plate technique.

    PubMed

    Simão, Mariela J; Collin, Myriam; Garcia, Renata O; Mansur, Elisabeth; Pacheco, Georgia; Engelmann, Florent

    2018-05-01

    Cryopreservation stands out as the main strategy to ensure safe and cost efficient long-term conservation of plant germplasm, especially for biotechnological materials. However, the injuries associated with the procedure may result in structural damage and low recovery rates after cooling. Histological analysis provides useful information on the effects of osmotic dehydration, LN exposure, and recovery conditions on cellular integrity and tissue organization, allowing the determination of the critical steps of the cryopreservation protocol and, thus, the use of optimized treatments. Passiflora pohlii Mast. (Passifloraceae) is a native species from Brazil with potential agronomic interest. Recent studies showed the presence of saponins in its roots, which presented antioxidant activity. The goal of this work was to develop a cryopreservation technique for root tips of in vitro-derived plants of P. pohlii using the V-Cryo-plate technique and to characterize the anatomical alterations that occurred during the successive steps of the protocol. Root tips were excised from in vitro plants and precultured before adhesion to cryo-plates and then treated for different periods with the plant vitrification solutions PVS2 or PVS3. Treatment with PVS2 for 45 min resulted in higher recovery (79%) when compared with PVS3 (43%). The greatest number of adventitious roots per cryopreserved explant was also observed after a 45-min exposure to PVS2. Plasmolysis levels were higher in cortical cells of cryopreserved explants treated with PVS2, while pericycle and central cylinder cells were not damaged after this treatment. Thirty days after rewarming, no plasmolysis could be detected, regardless of the experimental conditions.

  18. Electronic data collection for the analysis of surgical maneuvers on patients submitted to rhinoplasty

    PubMed Central

    Berger, Cezar; Freitas, Renato; Malafaia, Osvaldo; Pinto, José Simão de Paula; Mocellin, Marcos; Macedo, Evaldo; Fagundes, Marina Serrato Coelho

    2012-01-01

    Summary Introduction: In the health field, computerization has become increasingly necessary in professional practice, since it facilitates data recovery and assists in the development of research with greater scientific rigor. Objective: the present work aimed to develop, apply, and validate specific electronic protocols for patients referred for rhinoplasty. Methods: The prospective research had 3 stages: (1) preparation of theoretical data bases; (2) creation of a master protocol using Integrated System of Electronic Protocol (SINPE©); and (3) elaboration, application, and validation of a specific protocol for the nose and sinuses regarding rhinoplasty. Results: After the preparation of the master protocol, which dealt with the entire field of otorhinolaryngology, we idealized a specific protocol containing all matters related to the patient. In particular, the aesthetic and functional nasal complaints referred for surgical treatment (i.e., rhinoplasty) were organized into 6 main hierarchical categories: anamnesis, physical examination, complementary exams, diagnosis, treatment, and outcome. This protocol utilized these categories and their sub-items: finality; access; surgical maneuvers on the nasal dorsum, tip, and base; clinical evolution after 3, 6, and 12 months; revisional surgery; and quantitative and qualitative evaluations. Conclusion: The developed electronic-specific protocol is feasible and important for information registration from patients referred to rhinoplasty. PMID:25991979

  19. Method of making biocompatible electrodes

    DOEpatents

    Wollam, John S.

    1992-01-01

    A process of improving the sensing function of biocompatible electrodes and the product so made are disclosed. The process is designed to alter the surfaces of the electrodes at their tips to provide increased surface area and therefore decreased contact resistance at the electrode-tissue interface for increased sensitivity and essentially includes rendering the tips atomically clean by exposing them to bombardment by ions of an inert gas, depositing an adhesion layer on the cleaned tips, forming a hillocked layer on the adhesion layer by increasing the temperature of the tips, and applying a biocompatible coating on the hillocked layer. The resultant biocompatible electrode is characterized by improved sensitivity, minimum voltage requirement for organ stimulation and a longer battery life for the device in which it is employed.

  20. Extended Glauert tip correction to include vortex rollup effects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maniaci, David; Schmitz, Sven

    Wind turbine loads predictions by blade-element momentum theory using the standard tip-loss correction have been shown to over-predict loading near the blade tip in comparison to experimental data. This over-prediction is theorized to be due to the assumption of light rotor loading, inherent in the standard tip-loss correction model of Glauert. A higher- order free-wake method, WindDVE, is used to compute the rollup process of the trailing vortex sheets downstream of wind turbine blades. Results obtained serve an exact correction function to the Glauert tip correction used in blade-element momentum methods. Lastly, it is found that accounting for the effectsmore » of tip vortex rollup within the Glauert tip correction indeed results in improved prediction of blade tip loads computed by blade-element momentum methods.« less

  1. Extended Glauert tip correction to include vortex rollup effects

    DOE PAGES

    Maniaci, David; Schmitz, Sven

    2016-10-03

    Wind turbine loads predictions by blade-element momentum theory using the standard tip-loss correction have been shown to over-predict loading near the blade tip in comparison to experimental data. This over-prediction is theorized to be due to the assumption of light rotor loading, inherent in the standard tip-loss correction model of Glauert. A higher- order free-wake method, WindDVE, is used to compute the rollup process of the trailing vortex sheets downstream of wind turbine blades. Results obtained serve an exact correction function to the Glauert tip correction used in blade-element momentum methods. Lastly, it is found that accounting for the effectsmore » of tip vortex rollup within the Glauert tip correction indeed results in improved prediction of blade tip loads computed by blade-element momentum methods.« less

  2. Numerical investigation of tip clearance effects on the performance of ducted propeller

    NASA Astrophysics Data System (ADS)

    Ding, Yongle; Song, Baowei; Wang, Peng

    2015-09-01

    Tip clearance loss is a limitation of the improvement of turbomachine performance. Previous studies show the Tip clearance loss is generated by the leakage flow through the tip clearance, and is roughly linearly proportional to the gap size. This study investigates the tip clearance effects on the performance of ducted propeller. The investigation was carried out by solving the Navier-Stokes equations with the commercial Computational Fluid Dynamic (CFD) code CFX14.5. These simulations were carried out to determine the underlying mechanisms of the tip clearance effects. The calculations were performed at three different chosen advance ratios. Simulation results showed that the tip loss slope was not linearly at high advance due to the reversed pressure at the leading edge. Three type of vortical structures were observed in the tip clearance at different clearance size.

  3. Development and testing of tip devices for horizontal axis wind turbines

    NASA Technical Reports Server (NTRS)

    Gyatt, G. W.; Lissaman, P. B. S.

    1985-01-01

    A theoretical and field experimental program has been carried out to investigate the use of tip devices on horizontal axis wind turbine rotors. The objective was to improve performance by the reduction of tip losses. While power output can always be increased by a simple radial tip extension, such a modification also results in an increased gale load both because of the extra projected area and longer moment arm. Tip devices have the potential to increase power output without such a structural penalty. A vortex lattice computer model was used to optimize three basic tip configuration types for a 25 kW stall limited commercial wind turbine. The types were a change in tip planform, and a single-element and double-element nonplanar tip extension (winglets). A complete data acquisition system was developed which recorded three wind speed components, ambient pressure, temperature, and turbine output. The system operated unattended and could perform real-time processing of the data, displaying the measured power curve as data accumulated in either a bin sort mode or polynomial curve fit. Approximately 270 hr of perormance data were collected over a three-month period. The sampling interval was 2.4 sec; thrus over 400,000 raw data points were logged. Results for each of the three new tip devices, compared with the original tip, showed a small decrease (of the order of 1 kW) in power output over the measured range of wind speeds from cut-in at about 4 m/s to over 20 m/s, well into the stall limiting region. Changes in orientation and angle-of-attack of the winglets were not made. For aircraft wing tip devices, favorable tip shapes have been reported and it is likely that the tip devices tested in this program did not improve rotor performance because they were not optimally adjusted.

  4. JT8D high pressure compressor performance improvement

    NASA Technical Reports Server (NTRS)

    Gaffin, W. O.

    1981-01-01

    An improved performance high pressure compressor with potential application to all models of the JT8D engine was designed. The concept consisted of a trenched abradable rubstrip which mates with the blade tips for each of the even rotor stages. This feature allows tip clearances to be set so blade tips run at or near the optimum radius relative to the flowpath wall, without the danger of damaging the blades during transients and maneuvers. The improved compressor demonstrated thrust specific fuel consumption and exhaust gas temperature improvements of 1.0 percent and at least 10 C over the takeoff and climb power range at sea level static conditions, compared to a bill-of-material high pressure compressor. Surge margin also improved 4 percentage points over the high power operating range. A thrust specific fuel consumption improvement of 0.7 percent at typical cruise conditions was calculated based on the sea level test results.

  5. Selected advanced aerodynamics and active controls technology concepts development on a derivative B-747 aircraft

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Analytical design and wind tunnel test evaluations covering the feasibility of applying wing tip extensions, winglets, and active control wing had alleviation to the model B747 are described. Aerodynamic improvement offered by wing tip extension and winglet individually, and the combined aerodynamic and weight improvements when wing load alleviation is combined with the tip extension or the winglet are evaluated. Results are presented in the form of incremental effects on weight mission range, fuel usage, cost, and airline operating economics.

  6. A Simple Bioconjugate Attachment Protocol for Use in Single Molecule Force Spectroscopy Experiments Based on Mixed Self-Assembled Monolayers

    PubMed Central

    Attwood, Simon J.; Simpson, Anna M. C.; Stone, Rachael; Hamaia, SamirW.; Roy, Debdulal; Farndale, RichardW.; Ouberai, Myriam; Welland, Mark E.

    2012-01-01

    Single molecule force spectroscopy is a technique that can be used to probe the interaction force between individual biomolecular species. We focus our attention on the tip and sample coupling chemistry, which is crucial to these experiments. We utilised a novel approach of mixed self-assembled monolayers of alkanethiols in conjunction with a heterobifunctional crosslinker. The effectiveness of the protocol is demonstrated by probing the biotin-avidin interaction. We measured unbinding forces comparable to previously reported values measured at similar loading rates. Specificity tests also demonstrated a significant decrease in recognition after blocking with free avidin. PMID:23202965

  7. Transient Expression of Chimeric Fluorescent Reporter Proteins in Pollen Tubes to Study Protein Polar Secretion and Dynamics.

    PubMed

    Zhong, Guitao; Liu, Ronghe; Zhuang, Menglong; Wang, Hao

    2017-01-01

    Transient expression of chimeric fluorescent reporter proteins by biolistic bombardment is a quick and useful procedure for studying subcellular protein localization and dynamics in plants. It is especially beneficial in specific plant cells which are not suitable for protoplast-based and Agrobacterium-mediated protein transient expression. Polar protein secretion and vesicular trafficking play essential functions for cell polarization and tip growth. The growing pollen tube is regarded as an ideal model plant cell system to study the machinery and regulation of polar protein trafficking and targeting. A large amount of newly synthesized proteins are packed and polarly transported to the apical region to support the rapid and highly polarized tip growth. Here, we described a detailed step-by-step protocol for the transient expression of chimeric fluorescent reporter proteins in growing Arabidopsis and tobacco pollen tubes to study polar transportation logistics and mechanisms. In addition, we have optimized the Arabidopsis and tobacco in vitro pollen germination medium and the conditions to maximize the efficiency of protein expression. As a proof of concept, we have used this protocol to express actin microfilament and late endosomal fluorescent markers in Arabidopsis and tobacco pollen tubes.

  8. Confronting Therapeutic Failure: A Conversation Guide

    PubMed Central

    2015-01-01

    We reflect on the impact of bad news on both clinician and patient in the setting of cancer treatment failure. We review the classic six-step SPIKES (setting, perception, invitation for information, knowledge, empathy, summarize and strategize) protocol for giving bad news that has been widely adopted since it was first published in this journal in 2005. The goal of such a conversation guide is to describe both the process and the tasks that constitute vital steps for clinicians and to comment on the emotional impact of the conversation on the clinician. Confronting therapeutic failure is the hardest task for oncologists. We offer practical tips derived from a thorough review of the evidence and our clinical experience. Implications for Practice: Discussing the failure of anticancer therapy remains a very difficult conversation for oncologists and their patients. In this article, the process of confronting this failure is broken down into various components, and practical tips are provided for clinicians following a classic protocol for breaking bad news. Also addressed are the emotions of the oncologist and the reasons why these conversations are typically so hard. These insights are based on solid research intended to deepen the therapeutic connection between physician and patient. PMID:26099747

  9. Tip-enhanced near-field Raman spectroscopy with a scanning tunneling microscope and side-illumination optics.

    PubMed

    Yi, K J; He, X N; Zhou, Y S; Xiong, W; Lu, Y F

    2008-07-01

    Conventional Raman spectroscopy (RS) suffers from low spatial resolution and low detection sensitivity due to the optical diffraction limit and small interaction cross sections. It has been reported that a highly localized and significantly enhanced electromagnetic field could be generated in the proximity of a metallic tip illuminated by a laser beam. In this study, a tip-enhanced RS system was developed to both improve the resolution and enhance the detection sensitivity using the tip-enhanced near-field effects. This instrument, by combining RS with a scanning tunneling microscope and side-illumination optics, demonstrated significant enhancement on both optical sensitivity and spatial resolution using either silver (Ag)-coated tungsten (W) tips or gold (Au) tips. The sensitivity improvement was verified by observing the enhancement effects on silicon (Si) substrates. Lateral resolution was verified to be below 100 nm by mapping Ag nanostructures. By deploying the depolarization technique, an apparent enhancement of 175% on Si substrates was achieved. Furthermore, the developed instrument features fast and reliable optical alignment, versatile sample adaptability, and effective suppression of far-field signals.

  10. Thin-film morphology of inkjet-printed single-droplet organic transistors using polarized Raman spectroscopy: effect of blending TIPS-pentacene with insulating polymer.

    PubMed

    James, David T; Kjellander, B K Charlotte; Smaal, Wiljan T T; Gelinck, Gerwin H; Combe, Craig; McCulloch, Iain; Wilson, Richard; Burroughes, Jeremy H; Bradley, Donal D C; Kim, Ji-Seon

    2011-12-27

    We report thin-film morphology studies of inkjet-printed single-droplet organic thin-film transistors (OTFTs) using angle-dependent polarized Raman spectroscopy. We show this to be an effective technique to determine the degree of molecular order as well as to spatially resolve the orientation of the conjugated backbones of the 6,13-bis(triisopropylsilylethynyl)pentacene (TIPS-Pentacene) molecules. The addition of an insulating polymer, polystyrene (PS), does not disrupt the π-π stacking of the TIPS-Pentacene molecules. Blending in fact improves the uniformity of the molecular morphology and the active layer coverage within the device and reduces the variation in molecular orientation between polycrystalline domains. For OTFT performance, blending enhances the saturation mobility from 0.22 ± 0.05 cm(2)/(V·s) (TIPS-Pentacene) to 0.72 ± 0.17 cm(2)/(V·s) (TIPS-Pentacene:PS) in addition to improving the quality of the interface between TIPS-Pentacene and the gate dielectric in the channel, resulting in threshold voltages of ∼0 V and steep subthreshold slopes.

  11. Trials of Improved Practices (TIPs) to Enhance the Dietary and Iron-Folate Intake during Pregnancy- A Quasi Experimental Study among Rural Pregnant Women of Varanasi, India.

    PubMed

    Shivalli, Siddharudha; Srivastava, Ratan Kumar; Singh, Gyan Prakash

    2015-01-01

    Behavior Change Communications (BCC) play a decisive role in modifying socio-cultural norms affecting the perception and nutritional practices during pregnancy. To examine the effectiveness of 'Trials of Improved Practices' (TIPs) on dietary and iron-folate intake during pregnancy. Community based quasi experimental study with a control group. Four villages of Chiraigaon Community Development Block of Varanasi, India from May 2010 and recruited from August 2010. End line assessment, after 12 weeks of intervention, was completed in April 2011. Pregnant women in 13-28 weeks of gestation. TIPs was implemented in addition to ongoing essential obstetric care services in two villages through 3 home (assessment, negotiation and evaluation) visits and only assessment and evaluation visits in the other two control villages. Interpersonal communication, endorsing the active participation of family members and home based reminder materials were the TIPs based strategies. The effect of TIPs was assessed by comparing key outcome variables at baseline and after 12 weeks of intervention. Hemoglobin%, anemia prevalence, weight gain, compliance for iron-folate supplementation and dietary intake of calorie, protein, calcium and iron. A total of 86 participants completed the study. At the end, mean hemoglobin levels were 11.5±1.24 g/dl and 10.37±1.38 g/dl in the TIPs and control groups, respectively. The prevalence of anemia reduced by half in TIPs group and increased by 2.4% in the control group. Weight gain (grams/week) was significantly (p<0.01) higher in TIPs group (326.9±91.8 vs. 244.6±97.4). More than 85% of the PW in TIPs group were compliant for Iron-folate and only 38% were compliant among controls. The mean intake of protein increased by 1.78gm in intervention group and decreased by 1.81 gm in controls (p<0.05). More than two thirds of PW in TIPs group were taking one extra meal and only one third of controls were doing the same. TIPs found to be an effective approach to improve the nutritional status of pregnant women in the study area. TIPs strategy could be further explored on larger sample representing different socio-cultural and geographical areas. Clinical Trial Registry of India CTRI/2015/02/005517.

  12. Nanostar probes for tip-enhanced spectroscopy

    NASA Astrophysics Data System (ADS)

    Kim, Woong; Kim, Nara; Park, Joon Won; Kim, Zee Hwan

    2015-12-01

    To overcome the current limit of tip-enhanced spectroscopy that is based on metallic nano-probes, we developed a new scanning probe with a metallic nanostar, a nanoparticle with sharp spikes. A Au nanoparticle of 5 nm was first attached to the end of a tip through DNA-DNA hybridization and mechanical pick-up. The nanoparticle was converted to a nanostar with a core diameter of ~70 nm and spike lengths between 50 nm and 80 nm through the reduction of Au3+ with ascorbic acid in the presence of Ag+. Fabrication yields of such tips exceeded 60%, and more than 80% of such tips showed a mechanical durability sufficient for use in scanning microscopy. Effectiveness of the new probes for tip-enhanced Raman scattering (TERS) and tip-enhanced fluorescence (TEF) was confirmed. The probes exhibited the necessary enhancement for TEF, and the tip-on and tip-off ratios varied between 5 and 100. This large tip-to-tip variability may arise from the uncontrolled orientation of the apexes of the spike with respect to the sample surface, which calls for further fabrication improvement. The result overall supports a new fabrication approach for the probe that is effective for tip-enhanced spectroscopy.To overcome the current limit of tip-enhanced spectroscopy that is based on metallic nano-probes, we developed a new scanning probe with a metallic nanostar, a nanoparticle with sharp spikes. A Au nanoparticle of 5 nm was first attached to the end of a tip through DNA-DNA hybridization and mechanical pick-up. The nanoparticle was converted to a nanostar with a core diameter of ~70 nm and spike lengths between 50 nm and 80 nm through the reduction of Au3+ with ascorbic acid in the presence of Ag+. Fabrication yields of such tips exceeded 60%, and more than 80% of such tips showed a mechanical durability sufficient for use in scanning microscopy. Effectiveness of the new probes for tip-enhanced Raman scattering (TERS) and tip-enhanced fluorescence (TEF) was confirmed. The probes exhibited the necessary enhancement for TEF, and the tip-on and tip-off ratios varied between 5 and 100. This large tip-to-tip variability may arise from the uncontrolled orientation of the apexes of the spike with respect to the sample surface, which calls for further fabrication improvement. The result overall supports a new fabrication approach for the probe that is effective for tip-enhanced spectroscopy. Electronic supplementary information (ESI) available: Illustrations of TERS and TEF experiments, information about the TEM images, scheme of surface preparation and peak assignments of TERS spectra. See DOI: 10.1039/c5nr06657c

  13. Comparison of different focusing fiber tips for improved oral diode laser surgery.

    PubMed

    Stock, Karl; Stegmayer, Thomas; Graser, Rainer; Förster, Wolfram; Hibst, Raimund

    2012-12-01

    State of the art for use of the fiber guided diode laser in dental therapy is the application of bare fibers. A novel concept with delivery fiber and exchangeable fiber tips enables the use of tips with special and optimized geometries for various applications. The aim of this study is the comparison of different focusing fiber tips for enhanced cutting efficacy in oral surgery. For this purpose various designs of tip geometry were investigated and optimized by ray tracing simulations. Two applicators, one with a sphere, and another one with a taper, were realized and tested on porcine gingiva (diode laser, 940 nm, 5 W/cw; 7 W/modulated). The cutting depth and quality were determined by light microscope. Histological sections of the cuts were prepared by a cryo-microtome and microscopically analyzed to determine the cut depths and thermal damage zones. The simulations show that, using a sphere as fiber tip, an intensity increase of up to a factor of 16.2 in air, and 13.2 in water compared to a bare 200 µm fiber can be achieved. Although offering high focusing factor in water, the cutting quality of the sphere was rather poor. This is probably caused by a derogation of the focusing quality due to contamination during cutting and light scattering. Much better results were achieved with conically shaped fiber tips. Compared to bare fibers they exhibit improved handling properties with no hooking, more regular and deeper cuts (5 W/cw: 2,393 ± 468 µm, compared to the cleaved bare fiber 5 W/cw: 711 ± 268 µm). The thermal damage zones of the cuts are comparable for the various tips and fibers. In conclusion the results of our study show that cutting quality and efficiency of diode laser on soft tissue can be significantly improved using conically shaped fiber tips. Copyright © 2012 Wiley Periodicals, Inc.

  14. Report on using TIPS (Teaching Information Processing System) in teaching physics and astronomy

    NASA Astrophysics Data System (ADS)

    Folland, Nathan O.; Marchini, Robert R.; Rhyner, Charles R.; Zeilik, Michael

    1983-05-01

    A computer-managed instruction system, TIPS, has been used for over a decade in the teaching of diverse disciplines. This paper describes the recent use of TIPS in physics and astronomy courses at Kansas State University, Memphis State University, University of New Mexico, and University of Wisconsin-Green Bay. Student reactions to TIPS were largely positive, but the degree of success in improving student performance reported in many articles has not been observed.

  15. Observations from varying the lift and drag inputs to a noise prediction method for supersonic helical tip speed propellers

    NASA Technical Reports Server (NTRS)

    Dittmar, J. H.

    1984-01-01

    Previous comparisons between calculated and measured supersonic helical tip speed propeller noise show them to have different trends of peak blade passing tone versus helical tip Mach number. It was postulated that improvements in this comparison could be made first by including the drag force terms in the prediction and then by reducing the blade lift terms at the tip to allow the drag forces to dominate the noise prediction. Propeller hub to tip lift distributions were varied, but they did not yield sufficient change in the predicted lift noise to improve the comparison. This result indicates that some basic changes in the theory may be needed. In addition, the noise predicted by the drag forces did not exhibit the same curve shape as the measured data. So even if the drag force terms were to dominate, the trends with helical tip Mach number for theory and experiment would still not be the same. The effect of the blade shock wave pressure rise was approxmated by increasing the drag coefficient at the blade tip. Predictions using this shock wdave approximation did have a curve shape similar to the measured data. This result indicates that the shock pressure rise probably controls the noise at supersonic tip speed and that the linear prediction method can give the proper noise trend with Mach number.

  16. Propeller noise caused by blade tip radial forces

    NASA Technical Reports Server (NTRS)

    Hanson, D. B.

    1986-01-01

    New experimental evidence which indicates the presence of leading edge and tip edge vortex flow on Prop-Fans is examined, and performance and noise consequences are addressed. It was shown that the tip edge vortex is a significant noise source, particularly for unswept Prop-Fan blades. Preliminary calculations revealed that the addition of the tip side edge source to single rotation Prop-Fans during take off conditions improved the agreement between experiment and theory at blade passing frequency. At high-speed conditions such as the Prop-Fan cruise point, the tip loading effect tends to cancel thickness noise.

  17. Note: Automated electrochemical etching and polishing of silver scanning tunneling microscope tips.

    PubMed

    Sasaki, Stephen S; Perdue, Shawn M; Rodriguez Perez, Alejandro; Tallarida, Nicholas; Majors, Julia H; Apkarian, V Ara; Lee, Joonhee

    2013-09-01

    Fabrication of sharp and smooth Ag tips is crucial in optical scanning probe microscope experiments. To ensure reproducible tip profiles, the polishing process is fully automated using a closed-loop laminar flow system to deliver the electrolytic solution to moving electrodes mounted on a motorized translational stage. The repetitive translational motion is controlled precisely on the μm scale with a stepper motor and screw-thread mechanism. The automated setup allows reproducible control over the tip profile and improves smoothness and sharpness of tips (radius 27 ± 18 nm), as measured by ultrafast field emission.

  18. Improved design for a low temperature scanning tunneling microscope with an in situ tip treatment stage.

    PubMed

    Kim, J-J; Joo, S H; Lee, K S; Yoo, J H; Park, M S; Kwak, J S; Lee, Jinho

    2017-04-01

    The Low Temperature Scanning Tunneling Microscope (LT-STM) is an extremely valuable tool not only in surface science but also in condensed matter physics. For years, numerous new ideas have been adopted to perfect LT-STM performances-Ultra-Low Vibration (ULV) laboratory and the rigid STM head design are among them. Here, we present three improvements for the design of the ULV laboratory and the LT-STM: tip treatment stage, sample cleaving stage, and vibration isolation system. The improved tip treatment stage enables us to perform field emission for the purpose of tip treatment in situ without exchanging samples, while our enhanced sample cleaving stage allows us to cleave samples at low temperature in a vacuum without optical access by a simple pressing motion. Our newly designed vibration isolation system provides efficient space usage while maintaining vibration isolation capability. These improvements enhance the quality of spectroscopic imaging experiments that can last for many days and provide increased data yield, which we expect can be indispensable elements in future LT-STM designs.

  19. Biophysics and clinical utility of irrigated-tip radiofrequency catheter ablation.

    PubMed

    Houmsse, Mahmoud; Daoud, Emile G

    2012-01-01

    Catheter ablation by radiofrequency (RF) energy has successfully eliminated cardiac tachyarrhythmias. RF ablation lesions are created by thermal energy. Electrode catheters with 4-mm-tips have been adequate to ablate arrhythmias located near the endocardium; however, the 4-mm-tip electrode does not readily ablate deeper tachyarrhythmia substrate. With 8- and 10-mm-tip RF electrodes, ablation lesions were larger; yet, these catheters are associated with increased risk for coagulum, char and thrombus formation, as well as myocardial steam rupture. Cooled-tip catheter technology was designed to cool the electrode tip, prevent excessive temperatures at the electrode tip-tissue interface, and thus allow continued delivery of RF current into the surrounding tissue. This ablation system creates larger and deeper ablation lesions and minimizes steam pops and thrombus formation. The purpose of this article is to review cooled-tip RF ablation biophysics and outcomes of clinical studies as well as to discuss future technological improvements.

  20. Turbine blade tip clearance measurement using a skewed dual-beam fiber optic sensor

    NASA Astrophysics Data System (ADS)

    Ye, De-chao; Duan, Fa-jie; Guo, Hao-tian; Li, Yangzong; Wang, Kai

    2012-08-01

    Optimization and active control of the tip clearance of turbine blades has been identified as a key to improve fuel efficiency, reduce emission, and increase service life of the engine. However, reliable and real-time tip clearance measurement is difficult due to the adverse environmental conditions that are typically found in a turbine. We describe a dual-beam fiber optic measurement system that can measure the tip timing and tip clearance simultaneously. Because the tip timing information is used to calculate the tip clearance, the method is insensitive to the signal intensity variation caused by fluctuations in environmental conditions such as light source instability, contamination, and blade tip imperfection. The system was calibrated and tested using experimental rotors. The test results indicated a high resolution of 4.5 μm and measurement accuracy of ±20 μm over the rotation speed range of 2000 to 10,000 rpm.

  1. Materials for advanced turbine engines. Volume 1: Advanced blade tip seal system

    NASA Technical Reports Server (NTRS)

    Zelahy, J. W.; Fairbanks, N. P.

    1982-01-01

    Project 3, the subject of this technical report, was structured toward the successful engine demonstration of an improved-efficiency, long-life, tip-seal system for turbine blades. The advanced tip-seal system was designed to maintain close operating clearances between turbine blade tips and turbine shrouds and, at the same time, be resistant to environmental effects including high-temperature oxidation, hot corrosion, and thermal cycling. The turbine blade tip comprised an environmentally resistant, activated-diffussion-bonded, monocrystal superalloy combined with a thin layer of aluminium oxide abrasive particles entrapped in an electroplated NiCr matrix. The project established the tip design and joint location, characterized the single-crystal tip alloy and abrasive tip treatment, and established the manufacturing and quality-control plans required to fully process the blades. A total of 171 blades were fully manufactured, and 100 were endurance and performance engine-tested.

  2. Elimination of two viruses which interact synergistically from sweetpotato by shoot tip culture and cryotherapy.

    PubMed

    Wang, Q C; Valkonen, J P T

    2008-12-01

    Sweet potato chlorotic stunt virus (SPCSV; Closteroviridae) and Sweet potato feathery mottle virus (SPFMV; Potyviridae) interact synergistically and cause severe diseases in co-infected sweetpotato plants (Ipomoea batatas). Sweetpotato is propagated vegetatively and virus-free planting materials are pivotal for sustainable production. Using cryotherapy, SPCSV and SPCSV were eliminated from all treated single-virus-infected and co-infected shoot tips irrespective of size (0.5-1.5mm including 2-4 leaf primordia). While shoot tip culture also eliminated SPCSV, elimination of SPFMV failed in 90-93% of the largest shoot tips (1.5mm) using this technique. Virus distribution to different leaf primordia and tissues within leaf primordia in the shoot apex and petioles was not altered by co-infection of the viruses in the fully virus-susceptible sweetpotato genotype used. SPFMV was immunolocalized to all types of tissues and up to the fourth-youngest leaf primordium. In contrast, SPCSV was detected only in the phloem and up to the fifth leaf primordium. Because only cells in the apical dome of the meristem and the two first leaf primordia survived cryotherapy, all data taken together could explain the results of virus elimination. The simple and efficient cryotherapy protocol developed for virus elimination can also be used for preparation of sweetpotato materials for long-term preservation.

  3. Submicrometer Emitter ESI Tips for Native Mass Spectrometry of Membrane Proteins in Ionic and Nonionic Detergents

    NASA Astrophysics Data System (ADS)

    Susa, Anna C.; Lippens, Jennifer L.; Xia, Zijie; Loo, Joseph A.; Campuzano, Iain D. G.; Williams, Evan R.

    2018-01-01

    Native mass spectrometry (native-MS) of membrane proteins typically requires a detergent screening protocol, protein solubilization in the preferred detergent, followed by protein liberation from the micelle by collisional activation. Here, submicrometer nano-ESI emitter tips are used for native-MS of membrane proteins solubilized in both nonionic and ionic detergent solutions. With the submicrometer nano-ESI emitter tips, resolved charge-state distributions of membrane protein ions are obtained from a 150 mM NaCl, 25 mM Tris-HCl with 1.1% octyl glucoside solution. The relative abundances of NaCl and detergent cluster ions at high m / z are significantly reduced with the submicrometer emitters compared with larger nano-ESI emitters that are commonly used. This technique is beneficial for significantly decreasing the abundances (by two to three orders of magnitude compared with the larger tip size: 1.6 μm) of detergent cluster ions formed from aqueous ammonium acetate solutions containing detergents that can overlap with the membrane protein ion signal. Resolved charge-state distributions of membrane protein ions from aqueous ammonium acetate solutions containing ionic detergents were obtained with the submicrometer nano-ESI emitters; this is the first report of native-MS of membrane proteins solubilized by ionic detergents. [Figure not available: see fulltext.

  4. Submicrometer Emitter ESI Tips for Native Mass Spectrometry of Membrane Proteins in Ionic and Nonionic Detergents.

    PubMed

    Susa, Anna C; Lippens, Jennifer L; Xia, Zijie; Loo, Joseph A; Campuzano, Iain D G; Williams, Evan R

    2018-01-01

    Native mass spectrometry (native-MS) of membrane proteins typically requires a detergent screening protocol, protein solubilization in the preferred detergent, followed by protein liberation from the micelle by collisional activation. Here, submicrometer nano-ESI emitter tips are used for native-MS of membrane proteins solubilized in both nonionic and ionic detergent solutions. With the submicrometer nano-ESI emitter tips, resolved charge-state distributions of membrane protein ions are obtained from a 150 mM NaCl, 25 mM Tris-HCl with 1.1% octyl glucoside solution. The relative abundances of NaCl and detergent cluster ions at high m /z are significantly reduced with the submicrometer emitters compared with larger nano-ESI emitters that are commonly used. This technique is beneficial for significantly decreasing the abundances (by two to three orders of magnitude compared with the larger tip size: 1.6 μm) of detergent cluster ions formed from aqueous ammonium acetate solutions containing detergents that can overlap with the membrane protein ion signal. Resolved charge-state distributions of membrane protein ions from aqueous ammonium acetate solutions containing ionic detergents were obtained with the submicrometer nano-ESI emitters; this is the first report of native-MS of membrane proteins solubilized by ionic detergents. Graphical Abstract.

  5. Numerical investigation of influence of tip leakage flow on secondary flow in transonic centrifugal compressor at design condition

    NASA Astrophysics Data System (ADS)

    Kaneko, Masanao; Tsujita, Hoshio

    2015-04-01

    In a centrifugal compressor, the leakage flow through the tip clearance generates the tip leakage vortex by the interaction with the main flow, and consequently makes the flow in the impeller passage more complex by the interaction with the passage vortex. In addition, the tip leakage vortex interacts with the shock wave on the suction surface near the blade tip in the transonic centrifugal compressor impeller. Therefore, the detailed examination for the influence of the tip leakage vortex becomes seriously important to improve the aerodynamic performance especially for the transonic centrifugal compressor. In this study, the flows in the transonic centrifugal compressor with and without the tip clearance at the design condition were analyzed numerically by using the commercial CFD code. The computed results revealed that the tip leakage vortex induced by the high loading at the blade tip around the leading edge affected the loss generation by the reduction or the suppression of the shock wave on the suction surface of the blade.

  6. Dielectrophoretic positioning of single nanoparticles on atomic force microscope tips for tip-enhanced Raman spectroscopy.

    PubMed

    Leiterer, Christian; Deckert-Gaudig, Tanja; Singh, Prabha; Wirth, Janina; Deckert, Volker; Fritzsche, Wolfgang

    2015-05-01

    Tip-enhanced Raman spectroscopy, a combination of Raman spectroscopy and scanning probe microscopy, is a powerful technique to detect the vibrational fingerprint of molecules at the nanometer scale. A metal nanoparticle at the apex of an atomic force microscope tip leads to a large enhancement of the electromagnetic field when illuminated with an appropriate wavelength, resulting in an increased Raman signal. A controlled positioning of individual nanoparticles at the tip would improve the reproducibility of the probes and is quite demanding due to usually serial and labor-intensive approaches. In contrast to commonly used submicron manipulation techniques, dielectrophoresis allows a parallel and scalable production, and provides a novel approach toward reproducible and at the same time affordable tip-enhanced Raman spectroscopy tips. We demonstrate the successful positioning of an individual plasmonic nanoparticle on a commercial atomic force microscope tip by dielectrophoresis followed by experimental proof of the Raman signal enhancing capabilities of such tips. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Facile Preparation of a Platinum Silicide Nanoparticle-Modified Tip Apex for Scanning Kelvin Probe Microscopy.

    PubMed

    Lin, Chun-Ting; Chen, Yu-Wei; Su, James; Wu, Chien-Ting; Hsiao, Chien-Nan; Shiao, Ming-Hua; Chang, Mao-Nan

    2015-12-01

    In this study, we propose an ultra-facile approach to prepare a platinum silicide nanoparticle-modified tip apex (PSM tip) used for scanning Kelvin probe microscopy (SKPM). We combined a localized fluoride-assisted galvanic replacement reaction (LFAGRR) and atmospheric microwave annealing (AMA) to deposit a single platinum silicide nanoparticle with a diameter of 32 nm on the apex of a bare silicon tip of atomic force microscopy (AFM). The total process was completed in an ambient environment in less than 3 min. The improved potential resolution in the SKPM measurement was verified. Moreover, the resolution of the topography is comparable to that of a bare silicon tip. In addition, the negative charges found on the PSM tips suggest the possibility of exploring the use of current PSM tips to sense electric fields more precisely. The ultra-fast and cost-effective preparation of the PSM tips provides a new direction for the preparation of functional tips for scanning probe microscopy.

  8. Oxygen-Free Welding Contact Tips

    NASA Technical Reports Server (NTRS)

    Pike, James F.

    1993-01-01

    Contact tips for gas/metal arc welding (GMAW) fabricated from oxygen-free copper. Prototype tips tested in robotic welding, for which application intended. Reduces electrical erosion, increases electrical conductivity, and reduces mechanical wear. Productivity of robotic welding increases while time during welding interrupted for removal and replacement of contact tips minimal. Improves alignment of joints and filler metal, reducing rate of rejection and repair of unacceptable weldments. Utility extends beyond aerospace industry to mass production of various types of hardware, including heavy off-highway construction equipment.

  9. Online monitoring of dynamic tip clearance of turbine blades in high temperature environments

    NASA Astrophysics Data System (ADS)

    Han, Yu; Zhong, Chong; Zhu, Xiaoliang; Zhe, Jiang

    2018-04-01

    Minimized tip clearance reduces the gas leakage over turbine blade tips and improves the thrust and efficiency of turbomachinery. An accurate tip clearance sensor, measuring the dynamic clearances between blade tips and the turbine case, is a critical component for tip clearance control. This paper presents a robust inductive tip clearance sensor capable of monitoring dynamic tip clearances of turbine machines in high-temperature environments and at high rotational speeds. The sensor can also self-sense the temperature at a blade tip in situ such that temperature effect on tip clearance measurement can be estimated and compensated. To evaluate the sensor’s performance, the sensor was tested for measuring the tip clearances of turbine blades under various working temperatures ranging from 700 K to 1300 K and at turbine rotational speeds ranging from 3000 to 10 000 rpm. The blade tip clearance was varied from 50 to 2000 µm. The experiment results proved that the sensor can accurately measure the blade tip clearances with a temporal resolution of 10 µm. The capability of accurately measuring the tip clearances at high temperatures (~1300 K) and high turbine rotation speeds (~30 000 rpm), along with its compact size, makes it promising for online monitoring and active control of blade tip clearances of high-temperature turbomachinery.

  10. Quick Tips Guide for Small Manufacturing Businesses

    EPA Pesticide Factsheets

    Small manufacturing businesses can use this Quick Tips Guide to be better prepared for future extreme weather events. This guide discusses keeping good records, improving housekeeping procedures, and training employees.

  11. Alternative techniques in root canal debridement

    NASA Astrophysics Data System (ADS)

    Luca, Ruxandra; Todea, Carmen; Bǎlǎbuc, Cosmin; Nica, Luminita; Armani, Giacomo; Locovei, Cosmin

    2014-01-01

    Studies have demonstrated that conventional chemo-mechanical preparation is limited regarding the decontamination of the endodontic space, which is why alternative techniques such as laser radiation have their importance in the modern endodontic treatment. The present study aims to assess the possibility of improving the debridement of the root canals by removing smear layer using Er: YAG laser radiation. We used 18 extracted teeth, which were subjected to the same initial protocol and then divided into 5 study groups: the control group has not been treated with laser; the other 4 groups were exposed to laser radiation using two different geometries peaks of quartz and two energy levels. Scanning electronic microscopy revealed an increased efficiency in the debridement of all interested areas when using PIPS and XPulse tips at proper energy. In the two groups treated with inferior laser energy, the debridement didn't prove to be superior to the conventional treatment.

  12. Customized atomic force microscopy probe by focused-ion-beam-assisted tip transfer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Andrew; Butte, Manish J., E-mail: manish.butte@stanford.edu

    2014-08-04

    We present a technique for transferring separately fabricated tips onto tipless atomic force microscopy (AFM) cantilevers, performed using focused ion beam-assisted nanomanipulation. This method addresses the need in scanning probe microscopy for certain tip geometries that cannot be achieved by conventional lithography. For example, in probing complex layered materials or tall biological cells using AFM, a tall tip with a high-aspect-ratio is required to avoid artifacts caused by collisions of the tip's sides with the material being probed. We show experimentally that tall (18 μm) cantilever tips fabricated by this approach reduce squeeze-film damping, which fits predictions from hydrodynamic theory, andmore » results in an increased quality factor (Q) of the fundamental flexural mode. We demonstrate that a customized tip's well-defined geometry, tall tip height, and aspect ratio enable improved measurement of elastic moduli by allowing access to low-laying portions of tall cells (T lymphocytes). This technique can be generally used to attach tips to any micromechanical device when conventional lithography of tips cannot be accomplished.« less

  13. Evaluation of helicopter noise due to b blade-vortex interaction for five tip configurations. [conducted in the Langley V/STOL tunnel

    NASA Technical Reports Server (NTRS)

    Hoad, D. R.

    1979-01-01

    The effect of tip shape modification on blade vortex interaction induced helicopter blade slap noise was investigated. Simulated flight and descent velocities which have been shown to produce blade slap were tested. Aerodynamic performance parameters of the rotor system were monitored to ensure properly matched flight conditions among the tip shapes. The tunnel was operated in the open throat configuration with treatment to improve the acoustic characteristics of the test chamber. Four promising tips were used along with a standard square tip as a baseline configuration. A detailed acoustic evaluation on the same rotor system of the relative applicability of the various tip configurations for blade slap noise reduction is provided.

  14. A Case Study of Team-Initiated Problem Solving Addressing Student Behavior in One Elementary School

    ERIC Educational Resources Information Center

    Todd, Anne W.; Horner, Robert H.; Berry, Dorothy; Sanders, Carol; Bugni, Michelle; Currier, Allison; Potts, Nicky; Newton, J. Stephen; Algozzine, Bob; Algozzine, Kate

    2012-01-01

    Team-Initiated Problem Solving (TIPS) is an approach for organizing school team meetings to improve identification of targeted problems, use of data in the development of solutions, and development of implemented action plans. TIPS has been demonstrated in single-case and randomized controlled trial studies to improve the effectiveness of teams to…

  15. Molecular tips for scanning tunneling microscopy: intermolecular electron tunneling for single-molecule recognition and electronics.

    PubMed

    Nishino, Tomoaki

    2014-01-01

    This paper reviews the development of molecular tips for scanning tunneling microscopy (STM). Molecular tips offer many advantages: first is their ability to perform chemically selective imaging because of chemical interactions between the sample and the molecular tip, thus improving a major drawback of conventional STM. Rational design of the molecular tip allows sophisticated chemical recognition; e.g., chiral recognition and selective visualization of atomic defects in carbon nanotubes. Another advantage is that they provide a unique method to quantify electron transfer between single molecules. Understanding such electron transfer is mandatory for the realization of molecular electronics.

  16. OVERVIEW, PRACTICAL TIPS AND POTENTIAL PITFALLS OF USING AUTOMATIC EXPOSURE CONTROL IN CT: SIEMENS CARE DOSE 4D.

    PubMed

    Söderberg, Marcus

    2016-06-01

    Today, computed tomography (CT) systems routinely use automatic exposure control (AEC), which modulates the tube current. However, for optimal use, there are several aspects of an AEC system that need to be considered. The purpose of this study was to provide an overview of the Siemens CARE Dose 4D AEC system, discuss practical tips and demonstrate potential pitfalls. Two adult anthropomorphic phantoms were examined using two different Siemens CT systems. When optimising the CT radiation dose and image quality, the projection angle of the localiser, patient centring, protocol selection, scanning direction and the use of protective devices requires special attention. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Soy- and rice-based processed complementary food increases nutrient intakes in infants and is equally acceptable with or without added milk powder.

    PubMed

    Paul, Keriann H; Dickin, Katherine L; Ali, Nadra S; Monterrosa, Eva C; Stoltzfus, Rebecca J

    2008-10-01

    Processed complementary foods (PCF) might mitigate several complementary feeding barriers in developing countries. Efficacy trials, however, have not shown substantial improvements in child growth, possibly due to inadequate formative research to assess acceptability and identify pitfalls. Milk powder might improve palatability of PCF but incurs a higher cost. We compared the acceptability of an instant soy-rice PCF without (SR) and with (SRM) milk powder. Best practices for formative evaluation of PCF are not established. We therefore compared findings from randomized trials of SR vs. SRM in 1-d sensory tests (n = 71 mother-infant dyads) vs. Trials of Improved Practices (TIPs), a 2-wk in-home mixed methods evaluation (n = 54 dyads). TIPs included interviews, disappearance rates, observations, and 24-h dietary recalls to assess acceptance, consumption of the 50 g/d ration, and impact on diet. Although mothers preferred SRM to SR in the sensory tests, children in the TIPs consumed >50 g/d of SR (87 +/- 9 g/d) and SRM (89 +/- 8 g/d) with no difference between the foods (P = 0.55). Despite some replacement of family food, energy (574 kJ/d; P < 0.001) and protein (19 g protein/d; P < 0.001) increased in both groups. Mothers' preferences for milk, more sugar in SR, and preparation with hot water were concerns raised in the sensory tests that proved insignificant in TIPs. However, TIPs uncovered new concerns of overconsumption and food safety. We found milk did not improve the acceptability of the soy-rice PCF and recommend TIPs as a useful tool for formative research of PCF interventions.

  18. Trials of Improved Practices (TIPs) to Enhance the Dietary and Iron-Folate Intake during Pregnancy- A Quasi Experimental Study among Rural Pregnant Women of Varanasi, India

    PubMed Central

    Shivalli, Siddharudha; Srivastava, Ratan Kumar; Singh, Gyan Prakash

    2015-01-01

    Background Behavior Change Communications (BCC) play a decisive role in modifying socio-cultural norms affecting the perception and nutritional practices during pregnancy. Objective To examine the effectiveness of ‘Trials of Improved Practices’ (TIPs) on dietary and iron-folate intake during pregnancy. Design Community based quasi experimental study with a control group Setting Four villages of Chiraigaon Community Development Block of Varanasi, India from May 2010 and recruited from August 2010. End line assessment, after 12 weeks of intervention, was completed in April 2011. Participants Pregnant women in 13–28 weeks of gestation Intervention TIPs was implemented in addition to ongoing essential obstetric care services in two villages through 3 home (assessment, negotiation and evaluation) visits and only assessment and evaluation visits in the other two control villages. Interpersonal communication, endorsing the active participation of family members and home based reminder materials were the TIPs based strategies. The effect of TIPs was assessed by comparing key outcome variables at baseline and after 12 weeks of intervention. Outcome Measures Hemoglobin%, anemia prevalence, weight gain, compliance for iron-folate supplementation and dietary intake of calorie, protein, calcium and iron. Results A total of 86 participants completed the study. At the end, mean hemoglobin levels were 11.5±1.24 g/dl and 10.37±1.38 g/dl in the TIPs and control groups, respectively. The prevalence of anemia reduced by half in TIPs group and increased by 2.4% in the control group. Weight gain (grams/week) was significantly (p<0.01) higher in TIPs group (326.9±91.8 vs. 244.6±97.4). More than 85% of the PW in TIPs group were compliant for Iron-folate and only 38% were compliant among controls. The mean intake of protein increased by 1.78gm in intervention group and decreased by 1.81 gm in controls (p<0.05). More than two thirds of PW in TIPs group were taking one extra meal and only one third of controls were doing the same. Conclusion TIPs found to be an effective approach to improve the nutritional status of pregnant women in the study area. TIPs strategy could be further explored on larger sample representing different socio-cultural and geographical areas. Trial Registration Clinical Trial Registry of India CTRI/2015/02/005517 PMID:26367775

  19. Tips on hybridizing, washing, and scanning affymetrix microarrays.

    PubMed

    Ares, Manuel

    2014-02-01

    Starting in the late 1990s, Affymetrix, Inc. produced a commercial system for hybridizing, washing, and scanning microarrays that was designed to be easy to operate and reproducible. The system used arrays packaged in a plastic cassette or chamber in which the prefabricated array was mounted and could be filled with fluid through resealable membrane ports either by hand or by an automated "fluidics station" specially designed to handle the arrays. A special rotating hybridization oven and a specially designed scanner were also required. Primarily because of automation and standardization the Affymetrix system was and still remains popular. Here, we provide a skeleton protocol with the potential pitfalls identified. It is designed to augment the protocols provided by Affymetrix.

  20. Multi-cored vortices support function of slotted wing tips of birds in gliding and flapping flight

    PubMed Central

    2017-01-01

    Slotted wing tips of birds are commonly considered an adaptation to improve soaring performance, despite their presence in species that neither soar nor glide. We used particle image velocimetry to measure the airflow around the slotted wing tip of a jackdaw (Corvus monedula) as well as in its wake during unrestrained flight in a wind tunnel. The separated primary feathers produce individual wakes, confirming a multi-slotted function, in both gliding and flapping flight. The resulting multi-cored wingtip vortex represents a spreading of vorticity, which has previously been suggested as indicative of increased aerodynamic efficiency. Considering benefits of the slotted wing tips that are specific to flapping flight combined with the wide phylogenetic occurrence of this configuration, we propose the hypothesis that slotted wings evolved initially to improve performance in powered flight. PMID:28539482

  1. Conducting a successful residency research project.

    PubMed

    Barletta, Jeffrey F

    2008-08-15

    The residency research project can be a challenging endeavor for pharmacy residents since they typically have limited experience in this area. Furthermore, as the number of accredited residency programs has increased, so has the demand for preceptors with research experience. This review is intended to assist the resident and preceptor by providing steps and guidance with conducting a successful residency research project. Items such as idea generation, proposing the right type of project, departmental review, and project management skills are discussed and guidance with writing the research protocol is provided. Items that must be addressed in every research protocol are described and a generalized protocol template is presented. In addition, the institutional review board review process is described and tips and pointers for obtaining approval are included. Finally, useful tools and resources are provided that can be used up front or throughout each phase of the research project.

  2. DNA stable-isotope probing (DNA-SIP).

    PubMed

    Dunford, Eric A; Neufeld, Josh D

    2010-08-02

    DNA stable-isotope probing (DNA-SIP) is a powerful technique for identifying active microorganisms that assimilate particular carbon substrates and nutrients into cellular biomass. As such, this cultivation-independent technique has been an important methodology for assigning metabolic function to the diverse communities inhabiting a wide range of terrestrial and aquatic environments. Following the incubation of an environmental sample with stable-isotope labelled compounds, extracted nucleic acid is subjected to density gradient ultracentrifugation and subsequent gradient fractionation to separate nucleic acids of differing densities. Purification of DNA from cesium chloride retrieves labelled and unlabelled DNA for subsequent molecular characterization (e.g. fingerprinting, microarrays, clone libraries, metagenomics). This JoVE video protocol provides visual step-by-step explanations of the protocol for density gradient ultracentrifugation, gradient fractionation and recovery of labelled DNA. The protocol also includes sample SIP data and highlights important tips and cautions that must be considered to ensure a successful DNA-SIP analysis.

  3. Heat Transfer and Flow on the First Stage Blade Tip of a Power Generation Gas Turbine. Part 2; Simulation Results

    NASA Technical Reports Server (NTRS)

    Ameri, A. A.; Bunker, R. S.

    1999-01-01

    A combined experimental and computational study has been performed to investigate the detailed distribution of convective heat transfer coefficients on the first stage blade tip surface for a geometry typical of large power generation turbines (>1OOMW). This paper is concerned with the numerical prediction of the tip surface heat transfer. Good comparison with the experimental measured distribution was achieved through accurate modeling of the most important features of the blade passage and heating arrangement as well as the details of experimental rig likely to affect the tip heat transfer. A sharp edge and a radiused edge tip were considered. The results using the radiused edge tip agreed better with the experimental data. This improved agreement was attributed to the absence of edge separation on the tip of the radiused edge blade.

  4. Refining MARGINS Mini-Lessons Using Classroom Observations

    NASA Astrophysics Data System (ADS)

    Iverson, E. A.; Manduca, C. A.; McDaris, J. R.; Lee, S.

    2009-12-01

    One of the challenges that we face in developing teaching materials or activities from research findings is testing the materials to determine that they work as intended. Traditionally faculty develop material for their own class, notice what worked and didn’t, and improve them the next year. However, as we move to a community process of creating and sharing teaching materials, a community-based process for testing materials is appropriate. The MARGINS project has piloted such a process for testing teaching materials and activities developed as part of its mini-lesson project (http://serc.carleton.edu/margins/index.html). Building on prior work developing mechanisms for community review of teaching resources (e.g. Kastens, 2002; Hancock and Manduca, 2005; Mayhew and Hall, 2007), the MARGINS evaluation team developed a structured classroom observation protocol. The goals of field testing are to a) gather structured, consistent feedback for the lesson authors based on classroom use; b) guide reviewers of these lessons to reflect on research-based educational practice as a framework for their comments; c) collect information on the data and observations that the reviewer used to underpin their review; d) determine which mini-lessons are ready to be made widely available on the website. The protocol guides faculty observations on why they used the activity, the effectiveness of the activity in their classroom, the success of the activity in leading to the desired learning, and what other faculty need to successfully use the activity. Available online (http://serc.carleton.edu/margins/protocol.html), the protocol can be downloaded and completed during instruction with the activity. In order to encourage review of mini-lessons using the protocol, a workshop focused on review and revision of activities was held in May 2009. In preparation for the workshop, 13 of the 28 participants chose to field test a mini-lesson prior to the workshop and reported that they found this process instructive. Activity authors found the observations very helpful and the first mini-lessons have now been revised using feedback from testers. Initial results show that the tested mini-lessons give students hands-on experience with scientific data and help students make connections between geologic phenomena and data. Productive feedback ranged from suggestions for improving activity design, adaptations for other audiences, suggestions for clearer presentation, and tips for using the materials. The team plans to broaden the use of the protocol to test and refine all of the mini-lessons in the MARGINS collection.

  5. High loading, 1800 ft/sec tip speed, transonic compressor fan stage. 2: Final report

    NASA Technical Reports Server (NTRS)

    Morris, A. L.; Sulam, D. H.

    1972-01-01

    Tests were conducted on a 0.5 hub/tip ratio, single-stage fan-compressor designed to produce a pressure ratio of 2.285 an efficiency of 84 percent with a rotor tip speed of 1800 feet per second. A peak efficiency of 82 percent was achieved by the stage at a stall margin of 6.5 percent. Tests showed that stall-limit line was slightly sensitive to tip-radial distortion, but stall-line improvements were noted when the stage was subjected to circumferential and hub-radial flow distortions. Rotor blade passage and trailing edge shock positions were inferred from static pressure contours over the rotor tips.

  6. Improved recovery of cryotherapy-treated shoot tips following thermotherapy of in vitro-grown stock shoots of raspberry (Rubus idaeus L.).

    PubMed

    Wang, Qiaochun; Valkonen, Jari P T

    2009-01-01

    Raspberry bushy dwarf virus (RBDV) can be efficiently eradicated from raspberry plants (Rubus idaeus) by a procedure combining thermotherapy and cryotherapy. However, the bottleneck of this procedure is that, following thermotherapy, cryopreserved shoot tips become chlorotic during regrowth and eventually die after several subcultures. In addition, survival of heat-treated stock shoots and recovery of cryopreserved shoot tips following thermotherapy are low. The present study focused towards improving regrowth of cryopreserved raspberry shoot tips following thermotherapy. Results showed that preconditioning stock shoots with salicylic acid (SA; 0.01-0.1 mM) markedly increased survival of stock shoots after 4 weeks of thermotherapy. Regrowth of cryopreserved shoot tips following thermotherapy was also significantly enhanced when SA (0.05-0.1 mM) was used for preconditioning stock shoots. Addition of either Fe-ethylenediaminetetracetic acid (Fe-EDTA, 50 mg per L) or Fe-ethylenediaminedi(o)hydroxyphenylacetic acid (Fe-EDDHA, 50 mg per L) to post-culture medium strongly promoted regrowth and totally prevented chlorosis of shoots regenerated from cryopreserved shoot tips following thermotherapy. Using the parameters optimized in the present study, about 80 percent survival of heat-treated stock shoots and about 33 percent regrowth of cryopreserved shoot tips following thermotherapy were obtained. Morphology of plants regenerated from cryopreserved shoot tips following thermotherapy was identical to that of control plants, based on observations of leaf shape and size, internode length and plant height. Optimization of the thermotherapy procedure followed by cryotherapy will facilitate the wider application of this technique to eliminate viruses which can invade meristems.

  7. Improving Your Health: Tips for African American Men and Women

    MedlinePlus

    ... For Reporters Meetings & Workshops Follow Us Home Health Information Weight Management Health Tips for African-Americans Related Topics Section ... at NIDDK Technology Advancement & Transfer Meetings & Workshops Health Information ... Disease Urologic Diseases Endocrine Diseases Diet & Nutrition ...

  8. Teamcenter community : administration tips and tricks

    NASA Technical Reports Server (NTRS)

    Rangel, Gabriel

    2005-01-01

    This presentation covers what areas of prerequisites are important to understand and how one can improve performance and maintenance of an existing implementation. It will also cover tips and tricks for site migration and how to plan for upgrades.

  9. Device specific analysis of neonatal aortic outflow cannula jet flows for improved cardiopulmonary bypass hemodynamics

    NASA Astrophysics Data System (ADS)

    Menon, Prahlad; Sotiropoulos, Fotis; Undar, Akif; Pekkan, Kerem

    2011-11-01

    Hemodynamically efficient aortic outflow cannulae can provide high blood volume flow rates at low exit force during extracorporeal circulation in pediatric or neonatal cardiopulmonary bypass repairs. Furthermore, optimal hemolytic aortic insertion configurations can significantly reduce risk of post-surgical neurological complications and developmental defects in the young patient. The methodology and results presented in this study serve as a baseline for design of superior aortic outflow cannulae based on a novel paradigm of characterizing jet-flows at different flow regimes. In-silico evaluations of multiple cannula tips were used to delineate baseline hemodynamic performance of the popular pediatric cannula tips in an experimental cuboidal test-rig, using PIV. High resolution CFD jet-flow simulations performed for various cannula tips in the cuboidal test-rig as well as in-vivo insertion configurations have suggested the existence of optimal surgically relevant characteristics such as cannula outflow angle and insertion depth for improved hemodynamic performance during surgery. Improved cannula tips were designed with internal flow-control features for decreased blood damage and increased permissible flow rates.

  10. Multi-cored vortices support function of slotted wing tips of birds in gliding and flapping flight.

    PubMed

    KleinHeerenbrink, Marco; Johansson, L Christoffer; Hedenström, Anders

    2017-05-01

    Slotted wing tips of birds are commonly considered an adaptation to improve soaring performance, despite their presence in species that neither soar nor glide. We used particle image velocimetry to measure the airflow around the slotted wing tip of a jackdaw ( Corvus monedula ) as well as in its wake during unrestrained flight in a wind tunnel. The separated primary feathers produce individual wakes, confirming a multi-slotted function, in both gliding and flapping flight. The resulting multi-cored wingtip vortex represents a spreading of vorticity, which has previously been suggested as indicative of increased aerodynamic efficiency. Considering benefits of the slotted wing tips that are specific to flapping flight combined with the wide phylogenetic occurrence of this configuration, we propose the hypothesis that slotted wings evolved initially to improve performance in powered flight. © 2017 The Author(s).

  11. A compact CCD-monitored atomic force microscope with optical vision and improved performances.

    PubMed

    Mingyue, Liu; Haijun, Zhang; Dongxian, Zhang

    2013-09-01

    A novel CCD-monitored atomic force microscope (AFM) with optical vision and improved performances has been developed. Compact optical paths are specifically devised for both tip-sample microscopic monitoring and cantilever's deflection detecting with minimized volume and optimal light-amplifying ratio. The ingeniously designed AFM probe with such optical paths enables quick and safe tip-sample approaching, convenient and effective tip-sample positioning, and high quality image scanning. An image stitching method is also developed to build a wider-range AFM image under monitoring. Experiments show that this AFM system can offer real-time optical vision for tip-sample monitoring with wide visual field and/or high lateral optical resolution by simply switching the objective; meanwhile, it has the elegant performances of nanometer resolution, high stability, and high scan speed. Furthermore, it is capable of conducting wider-range image measurement while keeping nanometer resolution. Copyright © 2013 Wiley Periodicals, Inc.

  12. Ducted fan inlet/exit and rotor tip flow improvements for vertical lift systems

    NASA Astrophysics Data System (ADS)

    Akturk, Ali

    The current research utilized experimental and computational techniques in 5" and 22" diameter ducted fan test systems that have been custom designed and manufactured. Qualitative investigation of flow around the ducted fan was also performed using smoke flow visualizations. Quantitative measurements consisted of 2D and 3D velocity measurements using planar and Stereoscopic Particle Image Velocimetry (PIV and SPIV), high resolution total pressure measurements using Kiel total pressure probes and real time six-component force and torque measurements. The computational techniques used in this thesis included a recently developed radial equilibrium based rotor model(REBRM) and a three dimensional Reynolds-Averaged Navier Stokes (RANS) based CFD model. A radial equilibrium based rotor model (REBRM) developed by the author was effectively integrated into a three-dimensional RANS based computational system. The PIV measurements and computational flow predictions using (REBRM) near the fan inlet plane were in a good agreement at hover and forward flight conditions. The aerodynamic modifications resulting from the fan inlet flow distortions in forward flight regime were clearly captured in 2D PIV results. High resolution total pressure measurements at the downstream of the fan rotor showed that tip leakage, rotor hub separation, and passage flow related total pressure losses were dominant in hover condition. However, the losses were dramatically increased in forward flight because of inlet lip separation and distortion. A novel ducted fan inlet flow conditioning concept named "Double Ducted Fan" (DDF) was developed. The (DDF) concept has a potential to significantly improve the performance and controllability of VTOL UAVs and many other ducted fan based vertical lift systems. The new concept that will significantly reduce the inlet lip separation related performance penalties used a secondary stationary duct system to control "inlet lip separation" occurring especially at elevated forward flight velocities. The (DDF) is self-adjusting in a wide forward flight velocity range. DDFs corrective aerodynamic in influence becomes more pronounced with increasing flight velocity due to its inherent design properties. RANS simulations of the flow around rotor blades and duct geometry in the rotating frame of reference provided a comprehensive description of the tip leakage and passage flow in the flow environment of the two ducted fan research facilities developed throughout this thesis. The aerodynamic measurements and results of the RANS simulation showed good agreement especially near the tip region. A number of novel tip treatments based on custom designed pressure side extensions were introduced. Various tip leakage mitigation schemes were introduced by varying the chordwise location and the width of the extension in the circumferential direction. The current study showed that a proper selection of the pressure side bump location and width were the two critical parameters in influencing the success of the tip leakage mitigation approach. Significant gains in axial mean velocity component were observed when a proper pressure side tip extension was used. It is also observed that an effective tip leakage mitigation scheme significantly reduced the tangential velocity component near the tip of the axial fan blade. Reduced tip clearance related flow interactions were essential in improving the energy efficiency and range of ducted fan based vehicle. Full and inclined pressure side tip squealers were designed. Squealer tips were effective in changing the overall trajectory of the tip vortex to a higher path in radial direction. The interaction of rotor blades and tip vortex was effectively reduced and aerodynamic performance of the rotor blades was improved. The overall aerodynamic gain was a measurable reduction in leakage mass flow rate. This leakage reduction increased thrust significantly. Full and inclined pressure side tip squealers increased thrust obtained in hover condition by 9.1 % and 9.6 % respectively. A reduction or elimination of the momentum deficit in tip vortices is essential to reduce the adverse performance effects originating from the unsteady and highly turbulent tip leakage flows rotating against a stationary casing. The novel tip treatments developed throughout this thesis research are highly effective in reducing the adverse performance effects of ducted fan systems developed for VTOL vehicles. (Abstract shortened by UMI.)

  13. The effect of substrate on electric field enhancement of Tip-enhanced Raman spectroscopy (TERS)

    NASA Astrophysics Data System (ADS)

    Bahreini, Maryam

    2018-01-01

    The characterization of materials down to a few-molecule level is a key challenge in nanotechnology. Raman spectroscopy is a powerful method that provides chemical information via nondestructive vibrational fingerprinting. Unfortunately, this method suffers from signal weakness which prevents the study of small quantities. Tip-enhanced Raman spectroscopy (TERS) which combines the chemical sensitivity of Raman spectroscopy (RS) with high spatial resolution of scanning probe microscopy (SPM), provides chemical images of surfaces at the nanometer scale. In this method, irradiation of an SPM tip by a focused laser beam results in enhancement of local electric field via two reasons of localized surface plasmon resonance and lightning rod effect. This enhancement leads to the enhancement in Raman intensity from the sample surface in the vicinity of tip. In all TERS measurements, samples should be located on a substrate. In this paper, the dependence of the electric field enhancement to the substrate has been investigated. In simulations, three-dimensional finite-difference time-domain (3D-FDTD) method is used for numerical solution of Maxwell's equations. Our results show that the electric field enhancement is weak for the tip alone case. Introducing a substrate provides further electric field enhancement via near field electromagnetic dipole-dipole coupling between the tip and substrate. Since the side-illumination geometry is used for laser irradiation, the vertical component of the incident field plays a dominant role in the electric field enhancement. Therefore, the coupling effect between the tip and the substrate is the key contribution to the enhancement. For the case of silicon tip and the gold substrate, the electric field enhancement is improved considerably. There is an optimal tip size for TERS because of the competing effects of the radiation damping and the surface scattering of the tip. The results show the substrate as an effective tool for the improvement of the TERS detection sensitivity.

  14. Tips for Daily Living

    MedlinePlus

    ... Stories of Returning to School or Work Tough Work If You Can Get It Home Modifications Mental Health Tips for Maintaining a Positive Outlook and Well-Being Recreation Can Increase Awareness Improving Memory Submitting Your Story Stroke families put the ‘connection’ ...

  15. Analysis, design, fabrication and testing of an optical tip clearance sensor. [turbocompressor blade tips

    NASA Technical Reports Server (NTRS)

    Poppel, G. L.; Marple, D. T. F.; Kingsley, J. D.

    1981-01-01

    Analyses and the design, fabrication, and testing of an optical tip clearance sensor with intended application in aircraft propulsion control systems are reported. The design of a sensor test rig, evaluation of optical sensor components at elevated temperatures, sensor design principles, sensor test results at room temperature, and estimations of sensor accuracy at temperatures of an aircraft engine environment are discussed. Room temperature testing indicated possible measurement accuracies of less than 12.7 microns (0.5 mils). Ways to improve performance at engine operating temperatures are recommended. The potential of this tip clearance sensor is assessed.

  16. Shock isolator for operating a diode laser on a closed-cycle refrigerator

    NASA Technical Reports Server (NTRS)

    Jennings, D. E. (Inventor)

    1979-01-01

    A diode laser mounted within a helium refrigerator is mounted using a braided copper ground strap which provides good impact shock isolation from the refrigerator cold-tip while also providing a good thermal link to the cold-tip. The diode mount also contains a rigid stand-off assembly consisting of alternate sections of nylon and copper which serve as cold stations to improve thermal isolation from the vaccum housing mounting structure. Included in the mount is a Pb-In alloy wafer inserted between the cold-tip and the diode to damp temperature fluctuations occurring at the cold-tip.

  17. Lateral Tip Control Effects in CD-AFM Metrology: The Large Tip Limit.

    PubMed

    Dixson, Ronald G; Orji, Ndubuisi G; Goldband, Ryan S

    2016-01-25

    Sidewall sensing in critical dimension atomic force microscopes (CD-AFMs) usually involves continuous lateral dithering of the tip or the use of a control algorithm and fast response piezo actuator to position the tip in a manner that resembles touch-triggering of coordinate measuring machine (CMM) probes. All methods of tip position control, however, induce an effective tip width that may deviate from the actual geometrical tip width. Understanding the influence and dependence of the effective tip width on the dither settings and lateral stiffness of the tip can improve the measurement accuracy and uncertainty estimation for CD-AFM measurements. Since CD-AFM typically uses tips that range from 15 nm to 850 nm in geometrical width, the behavior of effective tip width throughout this range should be understood. The National Institute of Standards and Technology (NIST) has been investigating the dependence of effective tip width on the dither settings and lateral stiffness of the tip, as well as the possibility of material effects due to sample composition. For tip widths of 130 nm and lower, which also have lower lateral stiffness, the response of the effective tip width to lateral dither is greater than for larger tips. However, we have concluded that these effects will not generally result in a residual bias, provided that the tip calibration and sample measurement are performed under the same conditions. To validate that our prior conclusions about the dependence of effective tip width on lateral stiffness are valid for large CD-tips, we recently performed experiments using a very large non-CD tip with an etched plateau of approximately 2 μm width. The effective lateral stiffness of these tips is at least 20 times greater than typical CD-AFM tips, and these results supported our prior conclusions about the expected behavior for larger tips. The bottom-line importance of these latest observations is that we can now reasonably conclude that a dither slope of 3 nm/V is the baseline response due to the induced motion of the cantilever base.

  18. Lateral Tip Control Effects in CD-AFM Metrology: The Large Tip Limit

    PubMed Central

    Dixson, Ronald G.; Orji, Ndubuisi G.; Goldband, Ryan S.

    2016-01-01

    Sidewall sensing in critical dimension atomic force microscopes (CD-AFMs) usually involves continuous lateral dithering of the tip or the use of a control algorithm and fast response piezo actuator to position the tip in a manner that resembles touch-triggering of coordinate measuring machine (CMM) probes. All methods of tip position control, however, induce an effective tip width that may deviate from the actual geometrical tip width. Understanding the influence and dependence of the effective tip width on the dither settings and lateral stiffness of the tip can improve the measurement accuracy and uncertainty estimation for CD-AFM measurements. Since CD-AFM typically uses tips that range from 15 nm to 850 nm in geometrical width, the behavior of effective tip width throughout this range should be understood. The National Institute of Standards and Technology (NIST) has been investigating the dependence of effective tip width on the dither settings and lateral stiffness of the tip, as well as the possibility of material effects due to sample composition. For tip widths of 130 nm and lower, which also have lower lateral stiffness, the response of the effective tip width to lateral dither is greater than for larger tips. However, we have concluded that these effects will not generally result in a residual bias, provided that the tip calibration and sample measurement are performed under the same conditions. To validate that our prior conclusions about the dependence of effective tip width on lateral stiffness are valid for large CD-tips, we recently performed experiments using a very large non-CD tip with an etched plateau of approximately 2 μm width. The effective lateral stiffness of these tips is at least 20 times greater than typical CD-AFM tips, and these results supported our prior conclusions about the expected behavior for larger tips. The bottom-line importance of these latest observations is that we can now reasonably conclude that a dither slope of 3 nm/V is the baseline response due to the induced motion of the cantilever base. PMID:27087883

  19. Effect of the depressor septi nasi muscle modification on nasal tip rotation and projection.

    PubMed

    Toutounchi, Javad S; Biroon, Sogol H; Banaem, Samira M; Toutounchi, Neghisa S; Nezami, Nariman; Salari, Behzad

    2015-06-01

    The nasal tip is an important esthetic feature of the face and surgery on it is the most challenging part of a rhinoplasty. In the present study, we evaluated the effects of modification of the depressor septi nasi muscle on nasal tip rotation and projection. Eighty primary rhinoplasty patients who required nasal tip modifications were enrolled in a randomized clinical trial from October 2008 to March 2012. A study group composed of 40 patients underwent rhinoplasty including cutting and repositioning of the depressor septi nasi muscle and another group of 40 patients (control) underwent rhinoplasty without manipulation of the depressor septi nasi muscle. Nasal tip rotation and projection, and patient satisfaction were evaluated before and 6 months after the operation. Following rhinoplasty including cutting of the depressor septi nasi muscle, nasal tip rotation and projection, and patient satisfaction were improved in 70, 57.5, and 85 % of the patients, respectively; and in the control group, they were improved in 82.5, 55, and 67.5 %, respectively (P = 0.089, 0.607, and 0.069). Cutting and repositioning of the depressor septi nasi muscle as an adjunct to rhinoplasty is not associated with any additional advantage in terms of nasal tip rotation and projection, or patient satisfaction. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  20. In-planta detection and monitorization of endophytic colonization by a Beauveria bassiana strain using a new-developed nested and quantitative PCR-based assay and confocal laser scanning microscopy.

    PubMed

    Landa, B B; López-Díaz, C; Jiménez-Fernández, D; Montes-Borrego, M; Muñoz-Ledesma, F J; Ortiz-Urquiza, A; Quesada-Moraga, E

    2013-10-01

    Beauveria bassiana strain 04/01-Tip obtained from larvae of the opium poppy stem gall Iraella luteipes endophytically colonizes opium poppy plants and protect it against this pest. Development of a specific, rapid and sensitive technique that allows accurately determining the process and factors leading to the establishment of this strain in opium poppy plants would be essential to achieve its efficient control in a large field scale. For that purpose in the present study, species-specific primers that can be used in conventional or quantitative PCR protocols were developed for specifically identification and detection of B. bassiana in plant tissues. The combination of the designed BB.fw/BB.rv primer set with the universal ITS1-F/ITS4 primer set in a two-step nested-PCR approach, has allowed the amplification of up to 10fg of B. bassiana. This represented an increase in sensitivity of 10000- and 1000-fold of detection than when using the BB.fw/BB.rv primers in a single or single-tube semi-nested PCR approaches, respectively. The BB.fw and BB.rv primer set were subsequently optimized to be used in real time quantitative PCR assays and allowed to accurately quantify B. bassiana DNA in different plant DNA backgrounds (leaves and seeds) without losing accuracy and efficiency. The qPCR protocol was used to monitor the endophytic colonization of opium poppy leaves byB. bassiana after inoculation with the strain EABb 04/01-Tip, detecting as low as 26fg of target DNA in leaves and a decrease in fungal biomass over time. PCR quantification data were supported in parallel with CLMS by the monitoring of spatial and temporal patterns of leaf and stem colonization using a GFP-tagged transformant of the B. bassiana EABb 04/01-Tip strain, which enabled to demonstrate that B. bassiana effectively colonizes aerial tissues of opium poppy plants mainly through intercellular spaces and even leaf trichomes. A decline in endophytic colonization was also observed by the last sampling times, i.e. from 10 to 15days after inoculation, although fungal structures still remained present in the leaf tissues. These newly developed molecular protocols should facilitate the detection, quantification and monitoring of endophytic B. bassiana strains in different tissues and host plants and would help to unravel the factors and process governing the specific endophytic association between opium poppy and strain EABb 04/01-Tip providing key insights to formulate a sustainable strategy for I. luteipes management in the host. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Round Window Membrane Implantation with an Active Middle Ear Implant: A Study of the Effects on the Performance of Round Window Exposure and Transducer Tip Diameter in Human Cadaveric Temporal Bones

    PubMed Central

    Tringali, Stéphane; Koka, Kanthaiah; Deveze, Arnaud; Holland, N. Julian; Jenkins, Herman A.; Tollin, Daniel J.

    2010-01-01

    Objectives To assess the importance of 2 variables, transducer tip diameter and resection of the round window (RW) niche, affecting the optimization of the mechanical stimulation of the RW membrane with an active middle ear implant (AMEI). Materials and Methods: Ten temporal bones were prepared with combined atticotomy and facial recess approach to expose the RW. An AMEI stimulated the RW with 2 ball tip diameters (0.5 and 1.0 mm) before and after the resection of the bony rim of the RW niche. The RW drive performance, assessed by stapes velocities using laser Doppler velocimetry, was analyzed in 3 frequency ranges: low (0.25–1 kHz), medium (1–3 kHz) and high (3–8 kHz). Results Driving the RW produced mean peak stapes velocities (HEV) of 0.305 and 0.255 mm/s/V at 3.03 kHz, respectively, for the 1- and 0.5-mm tips, with the RW niche intact. Niche drilling increased the HEV to 0.73 and 0.832 mm/s/V for the 1- and 0.5-mm tips, respectively. The tip diameter produced no difference in output at low and medium frequencies; however, the 0.5-mm tip was 5 and 6 dB better than the 1-mm tip at high frequencies before and after niche drilling, respectively. Drilling the niche significantly improved the output by 4 dB at high frequencies for the 1-mm tip, and by 6 and 10 dB in the medium- and high-frequency ranges for the 0.5-mm tip. Conclusion The AMEI was able to successfully drive the RW membrane in cadaveric temporal bones using a classical facial recess approach. Stimulation of the RW membrane with an AMEI without drilling the niche is sufficient for successful hearing outputs. However, the resection of the bony rim of the RW niche significantly improved the RW stimulation at medium and higher frequencies. Drilling the niche enhances the exposure of the RW membrane and facilitates positioning the implant tip. PMID:20150727

  2. Performance and Vibratory Loads Data From a Wind-Tunnel Test of a Model Helicopter Main-Rotor Blade With a Paddle-Type Tip

    NASA Technical Reports Server (NTRS)

    Yeager, William T., Jr.; Noonan, Kevin W.; Singleton, Jeffrey D.; Wilbur, Matthew L.; Mirick, Paul H.

    1997-01-01

    An investigation was conducted in the Langley Transonic Dynamics Tunnel to obtain data to permit evaluation of paddle-type tip technology for possible use in future U.S. advanced rotor designs. Data was obtained for both a baseline main-rotor blade and a main-rotor blade with a paddle-type tip. The baseline and paddle-type tip blades were compared with regard to rotor performance, oscillatory pitch-link loads, and 4-per-rev vertical fixed-system loads. Data was obtained in hover and forward flight over a nominal range of advance ratios from 0.15 to 0.425. Results indicate that the paddle-type tip offers no performance improvements in either hover or forward flight. Pitch-link oscillatory loads for the paddle-type tip are higher than for the baseline blade, whereas 4-per-rev vertical fixed-system loads are generally lower.

  3. Nonlinear Aerodynamics and the Design of Wing Tips

    NASA Technical Reports Server (NTRS)

    Kroo, Ilan

    1991-01-01

    The analysis and design of wing tips for fixed wing and rotary wing aircraft still remains part art, part science. Although the design of airfoil sections and basic planform geometry is well developed, the tip regions require more detailed consideration. This is important because of the strong impact of wing tip flow on wing drag; although the tip region constitutes a small portion of the wing, its effect on the drag can be significant. The induced drag of a wing is, for a given lift and speed, inversely proportional to the square of the wing span. Concepts are proposed as a means of reducing drag. Modern computational methods provide a tool for studying these issues in greater detail. The purpose of the current research program is to improve the understanding of the fundamental issues involved in the design of wing tips and to develop the range of computational and experimental tools needed for further study of these ideas.

  4. Benchmarking the ERG valve tip and MRI Interventions Smart Flow neurocatheter convection-enhanced delivery system's performance in a gel model of the brain: employing infusion protocols proposed for gene therapy for Parkinson's disease

    NASA Astrophysics Data System (ADS)

    Sillay, Karl; Schomberg, Dominic; Hinchman, Angelica; Kumbier, Lauren; Ross, Chris; Kubota, Ken; Brodsky, Ethan; Miranpuri, Gurwattan

    2012-04-01

    Convection-enhanced delivery (CED) is an advanced infusion technique used to deliver therapeutic agents into the brain. CED has shown promise in recent clinical trials. Independent verification of published parameters is warranted with benchmark testing of published parameters in applicable models such as gel phantoms, ex vivo tissue and in vivo non-human animal models to effectively inform planned and future clinical therapies. In the current study, specific performance characteristics of two CED infusion catheter systems, such as backflow, infusion cloud morphology, volume of distribution (mm3) versus the infused volume (mm3) (Vd/Vi) ratios, rate of infusion (µl min-1) and pressure (mmHg), were examined to ensure published performance standards for the ERG valve-tip (VT) catheter. We tested the hypothesis that the ERG VT catheter with an infusion protocol of a steady 1 µl min-1 functionality is comparable to the newly FDA approved MRI Interventions Smart Flow (SF) catheter with the UCSF infusion protocol in an agarose gel model. In the gel phantom models, no significant difference was found in performance parameters between the VT and SF catheter. We report, for the first time, such benchmark characteristics in CED between these two otherwise similar single-end port VT with stylet and end-port non-stylet infusion systems. Results of the current study in agarose gel models suggest that the performance of the VT catheter is comparable to the SF catheter and warrants further investigation as a tool in the armamentarium of CED techniques for eventual clinical use and application.

  5. Treatment compliance in cystic fibrosis patients with chronic Pseudomonas aeruginosa infection treated with tobramycin inhalation powder: The FREE study.

    PubMed

    Blasi, Francesco; Carnovale, Vincenzo; Cimino, Giuseppe; Lucidi, Vincenzina; Salvatore, Donatello; Messore, Barbara; Bartezaghi, Marta; Muscianisi, Elisa; Porpiglia, Pasquale Alberto

    2018-05-01

    A high treatment burden with nebulised therapies in cystic fibrosis (CF) patients is the major limitation for treatment compliance; moreover, studies on treatment compliance with inhaled antibiotics are limited. This study assessed compliance to TOBI ® Podhaler™ (TIP) treatment in CF patients with chronic Pseudomonas aeruginosa (Pa) infections in a real-world setting using the Italian Treatment Adherence CF Questionnaire (ITA-CFq). This longitudinal, multicentre, cohort study included 2 follow-up (FU) visits: FU-1 at 3-months±15-days from the baseline visit and FU-2 at the end of third TIP cycle (or 6-months after enrolment, whichever occurred first). The effect of TIP on quality-of-life (QoL) and treatment satisfaction were evaluated using Cystic Fibrosis Questionnaire-Revised (CFQ-R) and Treatment Satisfaction Questionnaire for Medication (TSQM), respectively. Overall compliance to treatments was assessed using ITA-CFq. Eighty-two patients (mean age, 24.8 ± 7.9 years), including 22 paediatric patients (age, <18 years), were enrolled in the study; 56 (68.3%) patients, including 17 paediatric patients, completed the study. At baseline, the mean compliance score to aerosol antibiotic treatment was 7.8 ± 3.2; upon introducing TIP, the compliance score improved to 9.4 ± 1.2 at the FU-1 and thereafter remained stable at 9.5 ± 1.2. TSQM was higher for the convenience domain (74.2 ± 17.1 at enrolment and slightly improved to 77.8 ± 15.9 at FU-2) following TIP initiation. No substantial effect of TIP was observed on the QoL when measured using the revised CFQ-R. The safety profile was in line with previous findings. TIP was convenient to use and led to improved treatment adherence in CF patients with chronic Pa-infection. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Arc-starting aid for GTA welding

    NASA Technical Reports Server (NTRS)

    Whiffen, E. L.

    1977-01-01

    Three-in-one handtool combining arc-gap gage, electrode tip sander, and electrode projection gate, effectively improves initiation on gas tungsten arc (GTA), automatic skate-welding machines. Device effects ease in polishing electrode tips and setting exactly initial arc gap before each weld pass.

  7. Blade tip, finite aspect ratio, and dynamic stall effects on the Darrieus rotor

    NASA Astrophysics Data System (ADS)

    Paraschivoiu, I.; Desy, P.; Masson, C.

    1988-02-01

    The objective of the work described in this paper was to apply the Boeing-Vertol dynamic stall model in an asymmetric manner to account for the asymmetry of the flow between the left and right sides of the rotor. This phenomenon has been observed by the flow visualization of a two-straight-bladed Darrieus rotor in the IMST water tunnel. Also introduced into the aerodynamic model are the effects of the blade tip and finite aspect ratio on the aerodynamic performance of the Darrieus wind turbine. These improvements are compatible with the double-multiple-streamtube model and have been included in the CARDAAV computer code for predicting the aerodynamic performance. Very good agreement has been observed between the test data (Sandia 17 m) and theoretical predictions; a significant improvement over the previous dynamic stall model was obtained for the rotor power at low tip speed ratios, while the inclusion of the finite aspect ratio effects enhances the prediction of the rotor power for high tip speed ratios. The tip losses and finite aspect ratio effects were also calculated for a small-scale vertical-axis wind turbine, with a two-straight-bladed (NACA 0015) rotor.

  8. Phase-Imaging with a Sharpened Multi-Walled Carbon Nanotube AFM Tip: Investigation of Low-k Dielectric Polymer Hybrids

    NASA Technical Reports Server (NTRS)

    Nguyen, Cattien V.; Stevens, Ramsey M.; Meyyappan, M.; Volksen, Willi; Miller, Robert D.

    2005-01-01

    Phase shift tapping mode scanning force microscopy (TMSFM) has evolved into a very powerful technique for the nanoscale surface characterization of compositional variations in heterogeneous samples. Phase shift signal measures the difference between the phase angle of the excitation signal and the phase angle of the cantilever response. The signal correlates to the tip-sample inelastic interactions, identifying the different chemical and/or physical property of surfaces. In general, the resolution and quality of scanning probe microscopic images are highly dependent on the size of the scanning probe tip. In improving AFM tip technology, we recently developed a technique for sharpening the tip of a multi-walled carbon nanotube (CNT) AFM tip, reducing the radius of curvature of the CNT tip to less than 5 nm while still maintaining the inherent stability of multi-walled CNT tips. Herein we report the use of sharpened (CNT) AFM tips for phase-imaging of polymer hybrids, a precursor for generating nanoporous low-k dielectrics for on-chip interconnect applications. Using sharpened CNT tips, we obtained phase-contrast images having domains less than 10 nm. In contrast, conventional Si tips and unsharpened CNT tips (radius greater than 15 nm) were not able to resolve the nanoscale domains in the polymer hybrid films. C1early, the size of the CNT tip contributes significantly to the resolution of phase-contrast imaging. In addition, a study on the nonlinear tapping dynamics of the multi-walled CNT tip indicates that the multi-walled CNT tip is immune to conventional imaging instabilities related to the coexistence of attractive and repulsive tapping regimes. This factor may also contribute to the phase-contrast image quality of multi-walled CNT AFM tips. This presentation will also offer data in support of the stability of the CNT tip for phase shift TMSFM.

  9. Improving End-To-End Tsunami Warning for Risk Reduction on Canada’s West Coast

    DTIC Science & Technology

    2015-01-01

    Association Jason Wood , B.C. Ministry of Transportation and Infrastructure Steve Waugh, Bela Coola Dave Rainnie, Canadian Broadcasting Corporation...southern tip of Banks Island to the northern tip of Vancouver Island (the western limit of the eastern boundary of Cape Scot Provincial Park.) This... Scot to Port Renfrew Beginning on the eastern boundary of Cape Scot Provincial Park on the northern tip of Vancouver Island and running in a south

  10. Tips from the Classroom: Word Building [and] Can't Say "Yes" or "No" [and] Three-Peat or How to Engage Students in Revising Their Oral Presentations [and] Taking the Minutes Is Time Well Spent [and] Puzzles.

    ERIC Educational Resources Information Center

    Nicklous, Nan G.; And Others

    1997-01-01

    Presents useful tips for improving classroom learning. These include inviting native- and nonnative-English-speaking students to engage in world building while improving their language and cultural knowledge; highly motivated conversational activities; students' revision of their oral presentations; having students record classroom activities; and…

  11. Air-Cooled Turbine Blades with Tip Cap For Improved Leading-Edge Cooling

    NASA Technical Reports Server (NTRS)

    Calvert, Howard F.; Meyer, Andre J., Jr.; Morgan, William C.

    1959-01-01

    An investigation was conducted in a modified turbojet engine to determine the cooling characteristics of the semistrut corrugated air- cooled turbine blade and to compare and evaluate a leading-edge tip cap as a means for improving the leading-edge cooling characteristics of cooled turbine blades. Temperature data were obtained from uncapped air-cooled blades (blade A), cooled blades with the leading-edge tip area capped (blade B), and blades with slanted corrugations in addition to leading-edge tip caps (blade C). All data are for rated engine speed and turbine-inlet temperature (1660 F). A comparison of temperature data from blades A and B showed a leading-edge temperature reduction of about 130 F that could be attributed to the use of tip caps. Even better leading-edge cooling was obtained with blade C. Blade C also operated with the smallest chordwise temperature gradients of the blades tested, but tip-capped blade B operated with the lowest average chordwise temperature. According to a correlation of the experimental data, all three blade types 0 could operate satisfactorily with a turbine-inlet temperature of 2000 F and a coolant flow of 3 percent of engine mass flow or less, with an average chordwise temperature limit of 1400 F. Within the range of coolant flows investigated, however, only blade C could maintain a leading-edge temperature of 1400 F for a turbine-inlet temperature of 2000 F.

  12. Differences between the family-centered "COPCA" program and traditional infant physical therapy based on neurodevelopmental treatment principles.

    PubMed

    Dirks, Tineke; Blauw-Hospers, Cornill H; Hulshof, Lily J; Hadders-Algra, Mijna

    2011-09-01

    Evidence for effectiveness of pediatric physical therapy in infants at high risk for developmental motor disorders is limited. Therefore, "Coping With and Caring for Infants With Special Needs" (COPCA), a family-centered, early intervention program, was developed. The COPCA program is based on 2 components: (1) family involvement and educational parenting and (2) the neuromotor principles of the neuronal group selection theory. The COPCA coach uses principles of coaching to encourage the family's own capacities for solving problems of daily care and incorporating variation, along with trial and error in daily activities. The purpose of this study was to evaluate whether the content of sessions of the home-based, early intervention COPCA program differs from that of traditional infant physical therapy (TIP) sessions, which in the Netherlands are largely based on neurodevelopmental treatment. The study was conducted at the University Medical Center Groningen in the Netherlands. A quantitative video analysis of therapy sessions was conducted with infants participating in a 2-arm randomized trial. Forty-six infants at high risk for developmental motor disorders were randomly assigned to receive COPCA (n=21) or TIP (n=25) between 3 and 6 months corrected age. Intervention sessions were videotaped at 4 and 6 months corrected age and analyzed with a standardized observation protocol for the classification of physical therapy actions. Outcome parameters were relative amounts of time spent on specific physical therapy actions. The content of COPCA and TIP differed substantially. For instance, in TIP sessions, more time was spent on facilitation techniques, including handling, than in COPCA sessions (29% versus 3%, respectively). During COPCA, more time was spent on family coaching and education than during TIP (16% versus 4%, respectively). The major limitation of the study was its restriction to the Netherlands, implying that findings cannot be generalized automatically to other countries. The COPCA program differs broadly from TIP as applied in the Netherlands. Studies on the effectiveness of this family-centered program are needed.

  13. Influence of Needle Tip Distance on Barrier Discharge and Ozone Generation for Multiple Needles-Plane Electrode Configuration

    NASA Astrophysics Data System (ADS)

    Ueno, Hideki; Kawahara, Shintaro; Nakayama, Hiroshi

    Relationship between barrier discharge characteristics and ozone generation under ac voltage application on triple needles-plane configuration has been investigated for various distances among triple needle-tips (d=0 ∼ 7.0mm) at constant distance between needle tip and plane (g=3.0mm) in dry air. Characteristics of barrier discharge and ozone generation depend on the needle-tips distance. It is considered that the influence is caused by space charge and accumulated charge suggested from discharge image by still camera and CCD camera. And ozone generation efficiency is also estimated by power consumption and ozone concentration. As a result, when the distance among triple needle-tips is narrow, the above-mentioned influence is strengthened. And in this case, ozone generation efficiency is improved.

  14. Note: Low-temperature scanning tunneling microscope with detachable scanner and reliable transfer mechanism for tip and sample exchange

    NASA Astrophysics Data System (ADS)

    Ge, Weifeng; Wang, Jihao; Wang, Junting; Zhang, Jing; Hou, Yubin; Lu, Qingyou

    2017-12-01

    A homebuilt low-temperature scanning tunneling microscope (STM) featuring a detachable scanner based on a double slider design, along with a reliable transfer mechanism for tip and sample exchange, is present. The coarse motor is decoupled from the scanner, which prevents the motor instabilities including vibrations and drifts from entering the tip-sample loop and thus improves the performance of the STM. In addition, in situ exchange of tips and samples can be implemented easily and reliably using a winch-type transfer mechanism. Atomically resolved images on graphite are demonstrated to show the performance of the proposed STM.

  15. Time-of-Flight Tip-Clearance Measurements

    NASA Technical Reports Server (NTRS)

    Dhadwal, H. S.; Kurkov, A. P.; Janetzke, D. C.

    1999-01-01

    In this paper a time-of-flight probe system incorporating the two integrated fiber optic probes which are tilted equally relative to the probe holder centerline, is applied for the first time to measure the tip clearance of an advanced fan prototype. Tip clearance is largely independent of the signal amplitude and it relies on timing measurement. This work exposes optical effects associated with the fan blade stagger angle that were absent during the original spin-rig experiment on the zero stagger rotor. Individual blade tip clearances were measured with accuracy of +/- 127-mm (+/- 0.005-in). Probe features are discussed and improvements to the design are suggested.

  16. Note: Low-temperature scanning tunneling microscope with detachable scanner and reliable transfer mechanism for tip and sample exchange.

    PubMed

    Ge, Weifeng; Wang, Jihao; Wang, Junting; Zhang, Jing; Hou, Yubin; Lu, Qingyou

    2017-12-01

    A homebuilt low-temperature scanning tunneling microscope (STM) featuring a detachable scanner based on a double slider design, along with a reliable transfer mechanism for tip and sample exchange, is present. The coarse motor is decoupled from the scanner, which prevents the motor instabilities including vibrations and drifts from entering the tip-sample loop and thus improves the performance of the STM. In addition, in situ exchange of tips and samples can be implemented easily and reliably using a winch-type transfer mechanism. Atomically resolved images on graphite are demonstrated to show the performance of the proposed STM.

  17. An improved integrally formed radio frequency quadrupole

    DOEpatents

    Abbott, S.R.

    1987-10-05

    An improved radio frequency quadrupole is provided having an elongate housing with an elongate central axis and top, bottom and two side walls symmetrically disposed about the axis, and vanes formed integrally with the walls, the vanes each having a cross-section at right angles to the central axis which tapers inwardly toward the axis to form electrode tips spaced from each other by predetermined distances. Each of the four walls, and the vanes integral therewith, is a separate structural element having a central lengthwise plane passing through the tip of the vane, the walls having flat mounting surfaces at right angles to and parallel to the control plane, respectively, which are butted together to position the walls and vane tips relative to each other. 4 figs.

  18. Sealing apparatus for airfoils of gas turbine engines

    DOEpatents

    Jones, Russell B.

    1998-01-01

    An improved airfoil tip sealing apparatus is disclosed wherein brush seals are attached to airfoil tips with the distal ends of the brush seal fibers sealingly contacting opposing wall surfaces. Embodiments for variable vanes, stators and both cooled and uncooled turbine blade applications are disclosed.

  19. A novel protocol for dispatcher assisted CPR improves CPR quality and motivation among rescuers-A randomized controlled simulation study.

    PubMed

    Rasmussen, Stinne Eika; Nebsbjerg, Mette Amalie; Krogh, Lise Qvirin; Bjørnshave, Katrine; Krogh, Kristian; Povlsen, Jonas Agerlund; Riddervold, Ingunn Skogstad; Grøfte, Thorbjørn; Kirkegaard, Hans; Løfgren, Bo

    2017-01-01

    Emergency dispatchers use protocols to instruct bystanders in cardiopulmonary resuscitation (CPR). Studies changing one element in the dispatcher's protocol report improved CPR quality. Whether several changes interact is unknown and the effect of combining multiple changes previously reported to improve CPR quality into one protocol remains to be investigated. We hypothesize that a novel dispatch protocol, combining multiple beneficial elements improves CPR quality compared with a standard protocol. A novel dispatch protocol was designed including wording on chest compressions, using a metronome, regular encouragements and a 10-s rest each minute. In a simulated cardiac arrest scenario, laypersons were randomized to perform single-rescuer CPR guided with the novel or the standard protocol. a composite endpoint of time to first compression, hand position, compression depth and rate and hands-off time (maximum score: 22 points). Afterwards participants answered a questionnaire evaluating the dispatcher assistance. The novel protocol (n=61) improved CPR quality score compared with the standard protocol (n=64) (mean (SD): 18.6 (1.4)) points vs. 17.5 (1.7) points, p<0.001. The novel protocol resulted in deeper chest compressions (mean (SD): 58 (12)mm vs. 52 (13)mm, p=0.02) and improved rate of correct hand position (61% vs. 36%, p=0.01) compared with the standard protocol. In both protocols hands-off time was short. The novel protocol improved motivation among rescuers compared with the standard protocol (p=0.002). Participants guided with a standard dispatch protocol performed high quality CPR. A novel bundle of care protocol improved CPR quality score and motivation among rescuers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Role of Tat-interacting protein of 110 kDa and microRNAs in the regulation of hematopoiesis.

    PubMed

    Liu, Ying; He, Johnny J

    2016-07-01

    Hematopoiesis is regulated by cellular factors including transcription factors, microRNAs, and epigenetic modifiers. Understanding how these factors regulate hematopoiesis is pivotal for manipulating them to achieve their desired potential. In this review, we will focus on HIV-1 Tat-interacting protein of 110 kDa (Tip110) and its regulation of hematopoiesis. There are several pathways in hematopoiesis that involve Tip110 regulation. Tip110 is expressed in human cord blood CD34 cells; its expression decreases when CD34 cells begin to differentiate. Tip110 is also expressed in mouse marrow hematopoietic stem cells (HSC) and hematopoietic progenitor cells (HPC). Tip110 expression increases the number, survival, and cell cycling of HPC. Tip110-mediated regulation of hematopoiesis has been linked to its reciprocal control of proto-oncogene expression. Small noncoding microRNAs (miRs) have been shown to play important roles in regulation of hematopoiesis. miR-124 specifically targets 3'-untranslated region of Tip110 and subsequently regulates Tip110 expression in HSC. Our recent findings for manipulating expression levels of Tip110 in HSC and HPC could be useful for expanding HSC and HPC and for improving engraftment of cord blood HSC/HPC.

  1. Online immunoaffinity LC/MS/MS. A general method to increase sensitivity and specificity: How do you do it and what do you need?

    PubMed

    Dufield, Dawn R; Radabaugh, Melissa R

    2012-02-01

    There is an increased emphasis on hyphenated techniques such as immunoaffinity LC/MS/MS (IA-LC/MS/MS) or IA-LC/MRM. These techniques offer competitive advantages with respect to sensitivity and selectivity over traditional LC/MS and are complementary to ligand binding assays (LBA) or ELISA's. However, these techniques are not entirely straightforward and there are several tips and tricks to routine sample analysis. We describe here our methods and procedures for how to perform online IA-LC/MS/MS including a detailed protocol for the preparation of antibody (Ab) enrichment columns. We have included sample trapping and Ab methods. Furthermore, we highlight tips, tricks, minimal and optimal approaches. This technology has been shown to be viable for several applications, species and fluids from small molecules to proteins and biomarkers to PK assays. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Large Volume, Behaviorally-relevant Illumination for Optogenetics in Non-human Primates.

    PubMed

    Acker, Leah C; Pino, Erica N; Boyden, Edward S; Desimone, Robert

    2017-10-03

    This protocol describes a large-volume illuminator, which was developed for optogenetic manipulations in the non-human primate brain. The illuminator is a modified plastic optical fiber with etched tip, such that the light emitting surface area is > 100x that of a conventional fiber. In addition to describing the construction of the large-volume illuminator, this protocol details the quality-control calibration used to ensure even light distribution. Further, this protocol describes techniques for inserting and removing the large volume illuminator. Both superficial and deep structures may be illuminated. This large volume illuminator does not need to be physically coupled to an electrode, and because the illuminator is made of plastic, not glass, it will simply bend in circumstances when traditional optical fibers would shatter. Because this illuminator delivers light over behaviorally-relevant tissue volumes (≈ 10 mm 3 ) with no greater penetration damage than a conventional optical fiber, it facilitates behavioral studies using optogenetics in non-human primates.

  3. Tailoring protocols for chest CT applications: when and how?

    PubMed Central

    Iezzi, Roberto; Larici, Anna Rita; Franchi, Paola; Marano, Riccardo; Magarelli, Nicola; Posa, Alessandro; Merlino, Biagio; Manfredi, Riccardo; Colosimo, Cesare

    2017-01-01

    In the medical era of early detection of diseases and tailored therapies, an accurate characterization and staging of the disease is pivotal for treatment planning. The widespread use of computed tomography (CT)—often with the use of contrast material (CM)—probably represents the most important advance in diagnostic radiology. The result is a marked increase in radiation exposure of the population for medical purposes, with its intrinsic carcinogenic potential, and CM affecting kidney function. The radiologists should aim to minimize patient’s risk by reducing radiation exposure and CM amount, while maintaining the highest image quality. To achieve this goal, it is necessary to perform “patient-centric imaging”. The purpose of this review is to provide radiologists with “tips and tricks” to control radiation dose at CT, summarizing technical artifices in order to reduce image noise and increase image contrast. Also chest CT tailored protocols are supplied, with particular attention to three most common thoracic CT protocols: aortic/cardiac CT angiography (CTA), pulmonary CTA, and routine chest CT. PMID:29097345

  4. A Novel Approach for Reducing Rotor Tip-Clearance Induced Noise in Turbofan Engines

    NASA Technical Reports Server (NTRS)

    Khorrami, Mehdi R.; Li, Fei; Choudhari, Meelan

    2001-01-01

    Rotor tip-clearance induced noise, both in the form of rotor self noise and rotor-stator interaction noise , constitutes a significant component of total fan noise. Innovative yet cost effective techniques to suppress rotor-generated noise are, therefore, of foremost importance for improving the noise signature of turbofan engines. To that end, the feasibility of a passive porous treatment strategy to positively modify the tip-clearance flow field is addressed. The present study is focused on accurate viscous flow calculations of the baseline and the treated rotor flow fields. Detailed comparison between the computed baseline solution and experimental measurements shows excellent agreement. Tip-vortex structure, trajectory, strength, and other relevant aerodynamic quantities are extracted from the computed database. Extensive comparison between the untreated and treated tip-clearance flow fields is performed. The effectiveness of the porous treatment for altering the rotor-tip vortex flow field in general and reducing the intensity of the tip vortex, in particular, is demonstrated. In addition, the simulated flow field for the treated tip clearly shows that substantial reduction in the intensity of both the shear layer roll-up and boundary layer separation on the wall is achieved.

  5. Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts

    NASA Technical Reports Server (NTRS)

    Lattime, Scott B.; Steinetz, Bruce M.; Robbie, Malcolm G.

    2003-01-01

    Improved blade tip sealing in the high pressure compressor and high pressure turbine can provide dramatic improvements in specific fuel consumption, time-on-wing, compressor stall margin and engine efficiency as well as increased payload and mission range capabilities of both military and commercial gas turbine engines. The preliminary design of a mechanically actuated active clearance control (ACC) system for turbine blade tip clearance management is presented along with the design of a bench top test rig in which the system is to be evaluated. The ACC system utilizes mechanically actuated seal carrier segments and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. The purpose of this active clearance control system is to improve upon current case cooling methods. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, re-burst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). The active turbine blade tip clearance control system design presented herein will be evaluated to ensure that proper response and positional accuracy is achievable under simulated high-pressure turbine conditions. The test rig will simulate proper seal carrier pressure and temperature loading as well as the magnitudes and rates of blade tip clearance changes of an actual gas turbine engine. The results of these evaluations will be presented in future works.

  6. A new protocol for functional analysis of adipogenesis using reverse transfection technology and time-lapse video microscopy.

    PubMed

    Grönniger, Elke; Wessel, Sonja; Kühn, Sonja Christin; Söhle, Jörn; Wenck, Horst; Stäb, Franz; Winnefeld, Marc

    2010-07-01

    Since the worldwide increase in obesity represents a growing challenge for healthcare systems, research focusing on fat cell metabolism has become a focal point of interest. Here, we describe a small interfering RNA (siRNA)-technology-based screening method to study fat cell differentiation in human primary preadipocytes that could be further developed towards an automated middle-throughput screening procedure. First, we established optimal conditions for the reverse transfection of human primary preadipocytes demonstrating that an efficient reverse transfection of preadipocytes is technically feasible. Aligning the processes of reverse transfection and fat cell differentiation utilizing peroxisome proliferator-activated receptor gamma (PPAR gamma)-siRNA, we showed that preadipocyte differentiation was suppressed by knock-down of PPAR gamma, the key regulator of fat cell differentiation. The use of fluorescently labelled fatty acids in combination with fluorescence time-lapse microscopy over a longer period of time enabled us to quantify the PPAR gamma phenotype. Additionally, our data demonstrate that reverse transfection of human cultured preadipocytes with TIP60 (HIV-1 Tat-interacting protein 60)-siRNA lead to a TIP60 knock-down and subsequently inhibits fat cell differentiation, suggesting a role of this protein in human adipogenesis. In conclusion, we established a protocol that allows for an efficient functional and time-dependent analysis by quantitative time-lapse microscopy to identify novel adipogenesis-associated genes.

  7. Test Rig for Active Turbine Blade Tip Clearance Control Concepts: An Update

    NASA Technical Reports Server (NTRS)

    Taylor, Shawn; Steinetz, Bruce; Oswald, Jay; DeCastro, Jonathan; Melcher, Kevin

    2006-01-01

    The objective is to develop and demonstrate a fast-acting active clearance control system to improve turbine engine performance, reduce emissions, and increase service life. System studies have shown the benefits of reducing blade tip clearances in modern turbine engines. Minimizing blade tip clearances throughout the engine will contribute materially to meeting NASA's Ultra-Efficient Engine Technology (UEET) turbine engine project goals. NASA GRC is examining two candidate approaches including rub-avoidance and regeneration which are explained in subsequent slides.

  8. Ramped-rate vs continuous-rate infusions: An in vitro comparison of convection enhanced delivery protocols.

    PubMed

    Schomberg, Dominic; Wang, Anyi; Marshall, Hope; Miranpuri, Gurwattan; Sillay, Karl

    2013-04-01

    Convection enhanced delivery (CED) is a technique using infusion convection currents to deliver therapeutic agents into targeted regions of the brain. Recently, CED is gaining significant acceptance for use in gene therapy of Parkinson's disease (PD) employing direct infusion into the brain. CED offers advantages in that it targets local areas of the brain, bypasses the blood-brain barrier (BBB), minimizes systemic toxicity of the therapeutics, and allows for delivery of larger molecules that diffusion driven methods cannot achieve. Investigating infusion characteristics such as backflow and morphology is important in developing standard and effective protocols in order to successfully deliver treatments into the brain. Optimizing clinical infusion protocols may reduce backflow, improve final infusion cloud morphology, and maximize infusate penetrance into targeted tissue. The purpose of the current study was to compare metrics during ramped-rate and continuous-rate infusions using two different catheters in order to optimize current infusion protocols. Occasionally, the infusate refluxes proximally up the catheter tip, known as backflow, and minimizing this can potentially reduce undesirable effects in the clinical setting. Traditionally, infusions are performed at a constant rate throughout the entire duration, and backflow is minimized only by slow infusion rates, which increases the time required to deliver the desired amount of infusate. In this study, we investigate the effects of ramping and various infusion rates on backflow and infusion cloud morphology. The independent parameters in the study are: ramping, maximum infusion rate, time between rate changes, and increments of rate changes. Backflow was measured using two methods: i) at the point of pressure stabilization within the catheter, and ii) maximum backflow as shown by video data. Infusion cloud morphology was evaluated based on the height-to-width ratio of each infusion cloud at the end of each experiment. Results were tabulated and statistically analyzed to identify any significant differences between protocols. The experimental results show that CED rampedrate infusion protocols result in smaller backflow distances and more spherical cloud morphologies compared to continuous-rate infusion protocols ending at the same maximum infusion rate. Our results also suggest internal-line pressure measurements can approximate the time-point at which backflow ceases. Our findings indicate that ramping CED infusion protocols can potentially minimize backflow and produce more spherical infusion clouds. However, further research is required to determine the strength of this correlation, especially in relation to maximum infusion rates.

  9. Sealing apparatus for airfoils of gas turbine engines

    DOEpatents

    Jones, R.B.

    1998-05-19

    An improved airfoil tip sealing apparatus is disclosed wherein brush seals are attached to airfoil tips with the distal ends of the brush seal fibers sealingly contacting opposing wall surfaces. Embodiments for variable vanes, stators and both cooled and uncooled turbine blade applications are disclosed. 17 figs.

  10. Improving Parental Involvement: 10 Tips for Success.

    ERIC Educational Resources Information Center

    Warner, Laverne; Barrera, John

    2003-01-01

    Presents tips for organizing an effective parent involvement program: (1) develop a philosophy statement; (2) value family values, traditions, and beliefs; (3) reach out to parents; (4) train for effective communication; (5) encourage parent involvement in program activities; (6) provide involvement opportunities; (7) seek parental input; (8)…

  11. Fabrication and Demonstration of Mercury Disc-Well Probes for Stripping-Based Cyclic Voltammetry Scanning Electrochemical Microscopy.

    PubMed

    Barton, Zachary J; Rodríguez-López, Joaquín

    2017-03-07

    Scanning electrochemical microscopy (SECM) is a rising technique for the study of energy storage materials. Hg-based probes allow the extension of SECM investigations to ionic processes, but the risk of irreversible Hg amalgam saturation limits their operation to rapid timescales and dilute analyte solutions. Here, we report a novel fabrication protocol for Hg disc-well ultramicroelectrodes (UMEs), which retain access to stripping information but are less susceptible to amalgam saturation than traditional Hg sphere-caps or thin-films. The amalgamation and stripping behaviors of Hg disc-well UMEs are compared to those of traditional Hg sphere-cap UMEs and corroborated with data from finite element simulations. The improved protection against amalgam saturation allows Hg disc-wells to operate safely in highly concentrated environments at long timescales. The utility of the probes for bulk measurements extends also to SECM studies, where the disc geometry facilitates small tip-substrate gaps and improves both spatial and temporal resolution. Because they can carry out slow, high-resolution anodic stripping voltammetry approaches and imaging in concentrated solutions, Hg disc-well electrodes fill a new analytical niche for studies of ionic reactivity and are a valuable addition to the electrochemical toolbox.

  12. Closed-loop ARS mode for scanning ion conductance microscopy with improved speed and stability for live cell imaging applications.

    PubMed

    Jung, Goo-Eun; Noh, Hanaul; Shin, Yong Kyun; Kahng, Se-Jong; Baik, Ku Youn; Kim, Hong-Bae; Cho, Nam-Joon; Cho, Sang-Joon

    2015-07-07

    Scanning ion conductance microscopy (SICM) is an increasingly useful nanotechnology tool for non-contact, high resolution imaging of live biological specimens such as cellular membranes. In particular, approach-retract-scanning (ARS) mode enables fast probing of delicate biological structures by rapid and repeated approach/retraction of a nano-pipette tip. For optimal performance, accurate control of the tip position is a critical issue. Herein, we present a novel closed-loop control strategy for the ARS mode that achieves higher operating speeds with increased stability. The algorithm differs from that of most conventional (i.e., constant velocity) approach schemes as it includes a deceleration phase near the sample surface, which is intended to minimize the possibility of contact with the surface. Analysis of the ion current and tip position demonstrates that the new mode is able to operate at approach speeds of up to 250 μm s(-1). As a result of the improved stability, SICM imaging with the new approach scheme enables significantly improved, high resolution imaging of subtle features of fixed and live cells (e.g., filamentous structures & membrane edges). Taken together, the results suggest that optimization of the tip approach speed can substantially improve SICM imaging performance, further enabling SICM to become widely adopted as a general and versatile research tool for biological studies at the nanoscale level.

  13. Innovations for Evaluation Research: Multiform Protocols, Visual Analog Scaling, and the Retrospective Pretest-Posttest Design.

    PubMed

    Chang, Rong; Little, Todd D

    2018-06-01

    In this article, we review three innovative methods: multiform protocols, visual analog scaling, and the retrospective pretest-posttest design that can be used in evaluation research. These three techniques have been proposed for decades, but unfortunately, they are still not utilized readily in evaluation research. Our goal is to familiarize researchers with these underutilized research techniques that could reduce personnel effort and costs for data collection while producing better inferences for a study. We begin by discussing their applications and special unique features. We then discuss each technique's strengths and limitations and offer practical tips on how to better implement these methods in evaluation research. We then showcase two recent empirical studies that implement these methods in real-world evaluation research applications.

  14. Efficacy of smoking prevention program 'Smoke-free Kids': study protocol of a randomized controlled trial

    PubMed Central

    2009-01-01

    Background A strong increase in smoking is noted especially among adolescents. In the Netherlands, about 5% of all 10-year olds, 25% of all 13-year olds and 62% of all 17-year olds report ever smoking. In the U.S., an intervention program called 'Smoke-free Kids' was developed to prevent children from smoking. The present study aims to assess the effects of this home-based smoking prevention program in the Netherlands. Methods/Design A randomized controlled trial is conducted among 9 to 11-year old children of primary schools. Participants are randomly assigned to the intervention and control conditions. The intervention program consists of five printed activity modules designed to improve parenting skills specific to smoking prevention and parent-child communication regarding smoking. These modules will include additional sheets with communication tips. The modules for the control condition will include solely information on smoking and tobacco use. Initiation of cigarette smoking (first instance of puffing on a lighted cigarette), susceptibility to cigarette smoking, smoking-related cognitions, and anti-smoking socialization will be the outcome measures. To collect the data, telephone interviews with mothers as well as with their child will be conducted at baseline. Only the children will be examined at post-intervention follow-ups (6, 12, 24, and 36 months after the baseline). Discussion This study protocol describes the design of a randomized controlled trial that will evaluate the effectiveness of a home-based smoking prevention program. We expect that a significantly lower number of children will start smoking in the intervention condition compared to control condition as a direct result of this intervention. If the program is effective, it is applicable in daily live, which will facilitate implementation of the prevention protocol. Trial registration Netherlands Trial Register NTR1465 PMID:20025727

  15. Catalyst-induced growth of carbon nanotubes on tips of cantilevers and nanowires

    DOEpatents

    Lee, James Weifu; Lowndes, Douglas H.; Merkulov, Vladimir I.; Eres, Gyula; Wei, Yayi; Greenbaum, Elias; Lee, Ida

    2004-06-29

    A method is described for catalyst-induced growth of carbon nanotubes, nanofibers, and other nanostructures on the tips of nanowires, cantilevers, conductive micro/nanometer structures, wafers and the like. The method can be used for production of carbon nanotube-anchored cantilevers that can significantly improve the performance of scaning probe microscopy (AFM, EFM etc). The invention can also be used in many other processes of micro and/or nanofabrication with carbon nanotubes/fibers. Key elements of this invention include: (1) Proper selection of a metal catalyst and programmable pulsed electrolytic deposition of the desired specific catalyst precisely at the tip of a substrate, (2) Catalyst-induced growth of carbon nanotubes/fibers at the catalyst-deposited tips, (3) Control of carbon nanotube/fiber growth pattern by manipulation of tip shape and growth conditions, and (4) Automation for mass production.

  16. Imaging of soft material with carbon nanotube tip using near-field scanning microwave microscopy.

    PubMed

    Wu, Zhe; Sun, Wei-Qiang; Feng, Tao; Tang, Shawn Wenjie; Li, Gang; Jiang, Kai-Li; Xu, Sheng-Yong; Ong, Chong Kim

    2015-01-01

    In this manuscript, a near-field scanning microwave microscope (NSMM) of our own design is introduced while using a multi-walled carbon nanotube (MWCNT) bundle as the tip (referred to as 'CNT tip'). Clear images of gold-patterned numbers, photoresist stripes and corneal endothelial cells (cell line B4G12) were obtained by mapping the resonant frequency fr and S11 amplitude of a given area while the NSMM is operating in tapping mode. The CNT tip helps to improve image quality and reveals more information about the sample as compared to a traditional metallic tip. The CNT tip is flexible and does not scratch the surface of the sample during the scan, which is useful for imaging soft material in biological science. In the imaging of the B4G12 endothelial cells, the nuclei and cytoplasm can be clearly distinguished from the rest of the cell and its surrounding medium. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. A novel method for accurate needle-tip identification in trans-rectal ultrasound-based high-dose-rate prostate brachytherapy.

    PubMed

    Zheng, Dandan; Todor, Dorin A

    2011-01-01

    In real-time trans-rectal ultrasound (TRUS)-based high-dose-rate prostate brachytherapy, the accurate identification of needle-tip position is critical for treatment planning and delivery. Currently, needle-tip identification on ultrasound images can be subject to large uncertainty and errors because of ultrasound image quality and imaging artifacts. To address this problem, we developed a method based on physical measurements with simple and practical implementation to improve the accuracy and robustness of needle-tip identification. Our method uses measurements of the residual needle length and an off-line pre-established coordinate transformation factor, to calculate the needle-tip position on the TRUS images. The transformation factor was established through a one-time systematic set of measurements of the probe and template holder positions, applicable to all patients. To compare the accuracy and robustness of the proposed method and the conventional method (ultrasound detection), based on the gold-standard X-ray fluoroscopy, extensive measurements were conducted in water and gel phantoms. In water phantom, our method showed an average tip-detection accuracy of 0.7 mm compared with 1.6 mm of the conventional method. In gel phantom (more realistic and tissue-like), our method maintained its level of accuracy while the uncertainty of the conventional method was 3.4mm on average with maximum values of over 10mm because of imaging artifacts. A novel method based on simple physical measurements was developed to accurately detect the needle-tip position for TRUS-based high-dose-rate prostate brachytherapy. The method demonstrated much improved accuracy and robustness over the conventional method. Copyright © 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  18. Efficacy and Safety of Radiofrequency Ablation for Benign Thyroid Nodules: A Prospective Multicenter Study

    PubMed Central

    Jung, So Lyung; Lee, Jeong Hyun; Shong, Young Kee; Sung, Jin Yong; Kim, Kyu Sun; Lee, Ducky; Kim, Ji-hoon; Baek, Seon Mi; Sim, Jung Suk; Na, Dong Gyu

    2018-01-01

    Objective To assess the efficacy and safety of thyroid radiofrequency (RF) ablation for benign thyroid nodules by trained radiologists according to a unified protocol in a multi-center study. Materials and Methods From 2010 to 2011, 345 nodules from 345 patients (M:F = 43:302; mean age ± SD = 46.0 ± 12.7 years, range = 15–79) who met eligibility criteria were enrolled from five institutions. At pre-ablation, the mean volume was 14.2 ± 13.2 mL (1.1–80.8 mL). For 12 months or longer after treatment, 276 lesions, consisting of 248 solid and 28 predominantly cystic nodules, were followed. All operators performed RF ablation with a cool-tip RF system and two standard techniques (a transisthmic approach and the moving-shot technique). Volume reduction at 12 months after RF ablation (the primary outcome), therapeutic success, improvement of symptoms as well as of cosmetic problems, and complications were evaluated. Multiple linear regression analysis was applied to identify factors that were independently predictive of volume reduction. Results The mean volume reduction at 12 months was 80.3% (n = 276) and at the 24-, 36-, 48-, and 60-month follow-ups 84.3% (n = 198), 89.2% (n = 128), 91.9% (n = 57), and 95.3% (n = 6), respectively. Our therapeutic success was 97.8%. Both mean symptom and cosmetic scores showed significant improvements (p < 0.001). The rate of major complications was 1.0% (3/276). Solidity and applied energy were independent factors that predicted volume reduction. Conclusion Radiofrequency ablation performed by trained radiologists from multiple institutions using a unified protocol and similar devices was effective and safe for treating benign thyroid nodules. PMID:29354014

  19. Fabrication of electron beam deposited tip for atomic-scale atomic force microscopy in liquid.

    PubMed

    Miyazawa, K; Izumi, H; Watanabe-Nakayama, T; Asakawa, H; Fukuma, T

    2015-03-13

    Recently, possibilities of improving operation speed and force sensitivity in atomic-scale atomic force microscopy (AFM) in liquid using a small cantilever with an electron beam deposited (EBD) tip have been intensively explored. However, the structure and properties of an EBD tip suitable for such an application have not been well-understood and hence its fabrication process has not been established. In this study, we perform atomic-scale AFM measurements with a small cantilever and clarify two major problems: contaminations from a cantilever and tip surface, and insufficient mechanical strength of an EBD tip having a high aspect ratio. To solve these problems, here we propose a fabrication process of an EBD tip, where we attach a 2 μm silica bead at the cantilever end and fabricate a 500-700 nm EBD tip on the bead. The bead height ensures sufficient cantilever-sample distance and enables to suppress long-range interaction between them even with a short EBD tip having high mechanical strength. After the tip fabrication, we coat the whole cantilever and tip surface with Si (30 nm) to prevent the generation of contamination. We perform atomic-scale AFM imaging and hydration force measurements at a mica-water interface using the fabricated tip and demonstrate its applicability to such an atomic-scale application. With a repeated use of the proposed process, we can reuse a small cantilever for atomic-scale measurements for several times. Therefore, the proposed method solves the two major problems and enables the practical use of a small cantilever in atomic-scale studies on various solid-liquid interfacial phenomena.

  20. Carbon Nanotube Based Nano-Electro-Mechanical Systems (NEMS)

    NASA Technical Reports Server (NTRS)

    Han, Jie; Dai, Hongjie; Saini, Subhash

    1998-01-01

    Carbon nanotubes (CNT) enable nanoelectromechanical systems (NEMS) because of their inherent nanostructure, intrinsic electric conductivity and mechanical resilience. The collaborative work between Stanford (experiment) and NASA Ames (theory and simulation) has made progress in two types of CNT based NEMS for nanoelectronics and sensor applications. The CNT tipped scanning probe microscopy (SPM) is a NEMS in which CNT tips are used for nanoscale probing, imaging and manipulating. It showed great improvement in probing surfaces and biological systems over conventional tips. We have recently applied it to write (lithography) and read (image) uniform SiO2 lines on large Si surface area at speed up to 0.5 mm per s. Preliminary work using approximately 10 nm multiwall nanotube tips produced approximately 10 nm structures and showed that the CNT tips didn't wear down when crashed as conventional tips often do. This presents a solution to the long standing tip-wear problem in SPM nanolithography. We have also explored potential of CNT tips in imaging DNA in water. Preliminary experiment using 10 nm CNT tips reached 5 nm resolution. The 1 nm nanolithography and 1 nm DNA imaging can be expected by using approximately 1 nm CNT tips. In contrast to CNT tipped SPM, we also fabricated CNT devices on silicon wafer in which CNTs connect patterned metallic lines on SiO2/Si by a simple chemical vapor deposition process. Using conventional lithography for silicon wafer, we have been able to obtain CNT based transistors and sensors. Investigations of the CNT NEMS as physical, biological and chemical sensors are in progress and will be discussed.

  1. Tip Fence for Reduction of Lift-Generated Airframe Noise

    NASA Technical Reports Server (NTRS)

    Ross, James C. (Inventor); Storms, Bruce L. (Inventor)

    1998-01-01

    The present invention is directed toward a unique lift-generated noise reduction apparatus. This apparatus includes a plurality of tip fences that are secured to the trailing and leading assemblies of the high-lift system, as close as possible to the discontinuities where the vortices are most likely to form. In one embodiment, these tip fences are secured to some or all of the outboard and inboard tips of the wing slats and flaps. The tip fence includes a generally flat, or an aerodynamically shaped plate or device that could be formed of almost any rigid material, such as metal, wood, plastic, fiber glass, aluminum, etc. In a preferred embodiment, the tip fences extend below and perpendicularly to flaps and the slats to which they are attached, such that these tip fences are aligned with the nominal free stream velocity of the aircraft. In addition to reducing airframe noise, the tip fence tends to decrease drag and to increase lift, thus improving the overall aerodynamic performance of the aircraft. Another advantage presented by the tip fence lies in the simplicity of its design, its elegance, and its ready ability to fit on the wing components, such as the flaps and the slats. Furthermore, it does not require non-standard materials or fabrication techniques, and it can be readily, easily and inexpensively retrofited on most of the existing aircraft, with minimal design changes.

  2. Laser-only Adaptive Optics Achieves Significant Image Quality Gains Compared to Seeing-limited Observations over the Entire Sky

    NASA Astrophysics Data System (ADS)

    Howard, Ward S.; Law, Nicholas M.; Ziegler, Carl A.; Baranec, Christoph; Riddle, Reed

    2018-02-01

    Adaptive optics laser guide-star systems perform atmospheric correction of stellar wavefronts in two parts: stellar tip-tilt and high-spatial-order laser correction. The requirement of a sufficiently bright guide star in the field-of-view to correct tip-tilt limits sky coverage. In this paper, we show an improvement to effective seeing without the need for nearby bright stars, enabling full sky coverage by performing only laser-assisted wavefront correction. We used Robo-AO, the first robotic AO system, to comprehensively demonstrate this laser-only correction. We analyze observations from four years of efficient robotic operation covering 15000 targets and 42000 observations, each realizing different seeing conditions. Using an autoguider (or a post-processing software equivalent) and the laser to improve effective seeing independent of the brightness of a target, Robo-AO observations show a 39% ± 19% improvement to effective FWHM, without any tip-tilt correction. We also demonstrate that 50% encircled energy performance without tip-tilt correction remains comparable to diffraction-limited, standard Robo-AO performance. Faint-target science programs primarily limited by 50% encircled energy (e.g., those employing integral field spectrographs placed behind the AO system) may see significant benefits to sky coverage from employing laser-only AO.

  3. Collaborative writing: Tools and tips.

    PubMed

    Eapen, Bell Raj

    2007-01-01

    Majority of technical writing is done by groups of experts and various web based applications have made this collaboration easy. Email exchange of word processor documents with tracked changes used to be the standard technique for collaborative writing. However web based tools like Google docs and Spreadsheets have made the process fast and efficient. Various versioning tools and synchronous editors are available for those who need additional functionality. Having a group leader who decides the scheduling, communication and conflict resolving protocols is important for successful collaboration.

  4. Improved method for determining the stress relaxation at the crack tip

    NASA Astrophysics Data System (ADS)

    Grinevich, A. V.; Erasov, V. S.; Avtaev, V. V.

    2017-10-01

    A technique is suggested to determine the stress relaxation at the crack tip during tests of a specimen of a new type at a constant crack opening fixed by a stay bolt. The shape and geometry of the specimen make it possible to set the load and to determine the crack closure force after long-term exposure using the force transducer of a tensile-testing machine. The stress relaxation at the crack tip is determined in a V95pchT2 alloy specimen at elevated temperatures.

  5. Centering Pregnancy: practical tips for your practice.

    PubMed

    DeCesare, Julie Z; Jackson, Jessica R

    2015-03-01

    With increased access to care, current health delivery systems will need expansion to meet higher demands and needs. To define Centering Pregnancy and practical tips for implementation into both private and academic practices. Evidence was gathered through literature reviews. It was found that Centering Pregnancy offers a patient-centered, evidence-based approach to helping with access issues, as well as improving outcomes. This article describes the benefits of Centering Pregnancy to the practice, the provider, and the patient. Practical implementation tips will be offered, with suggestions for negating common implementation barriers.

  6. Aerodynamic Inner Workings of Circumferential Grooves in a Transonic Axial Compressor

    NASA Technical Reports Server (NTRS)

    Hah, Chunill; Mueller, Martin; Schiffer, Heinz-Peter

    2007-01-01

    The current paper reports on investigations of the fundamental flow mechanisms of circumferential grooves applied to a transonic axial compressor. Experimental results show that the compressor stall margin is significantly improved with the current set of circumferential grooves. The primary focus of the current investigation is to advance understanding of basic flow mechanics behind the observed improvement of stall margin. Experimental data and numerical simulations of a circumferential groove were analyzed in detail to unlock the inner workings of the circumferential grooves in the current transonic compressor rotor. A short length scale stall inception occurs when a large flow blockage is built on the pressure side of the blade near the leading edge and incoming flow spills over to the adjacent blade passage due to this blockage. The current study reveals that a large portion of this blockage is created by the tip clearance flow originating from 20% to 50% chord of the blade from the leading edge. Tip clearance flows originating from the leading edge up to 20% chord form a tip clearance core vortex and this tip clearance core vortex travels radially inward. The tip clearance flows originating from 20% to 50% chord travels over this tip clearance core vortex and reaches to the pressure side. This part of tip clearance flow is of low momentum as it is coming from the casing boundary layer and the blade suction surface boundary layer. The circumferential grooves disturb this part of the tip clearance flow close to the casing. Consequently the buildup of the induced vortex and the blockage near the pressure side of the passage is reduced. This is the main mechanism of the circumferential grooves that delays the formation of blockage near the pressure side of the passage and delays the onset of short length scale stall inception. The primary effect of the circumferential grooves is preventing local blockage near the pressure side of the blade leading edge that directly determines flow spillage around the leading edge. The circumferential grooves do not necessarily reduce the over all blockage built up at the rotor tip section.

  7. Makeover Madness: Tips for Revamping your Young Adult Area.

    ERIC Educational Resources Information Center

    Bolan, Kimberly; Wemett, Lisa C.

    1999-01-01

    Presents tips from a project that made modest but significant improvements to the young adult areas and services of 11 rural libraries in the Pioneer Library System in upstate New York. Discusses floor plans, layout and location; furniture and fixtures; collections and displays; technology; and staff. Illustrates changes with before-and-after…

  8. IAQ Tools for Schools: Managing Asthma in the School Environment.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Office of Radiation and Indoor Air.

    This manual provides tips on improving indoor air quality within the school environment by removing the elements that trigger asthma attacks in children, and presents a list of organizations where asthma resource information can be obtained. Air quality management tips cover removing of animal and cockroach allergens, cleaning up mold and…

  9. Evaluating the Performance of the ff99SB Force Field Based on NMR Scalar Coupling Data

    PubMed Central

    Wickstrom, Lauren; Okur, Asim; Simmerling, Carlos

    2009-01-01

    Abstract Force-field validation is essential for the identification of weaknesses in current models and the development of more accurate models of biomolecules. NMR coupling and relaxation methods have been used to effectively diagnose the strengths and weaknesses of many existing force fields. Studies using the ff99SB force field have shown excellent agreement between experimental and calculated order parameters and residual dipolar calculations. However, recent studies have suggested that ff99SB demonstrates poor agreement with J-coupling constants for short polyalanines. We performed extensive replica-exchange molecular-dynamics simulations on Ala3 and Ala5 in TIP3P and TIP4P-Ew solvent models. Our results suggest that the performance of ff99SB is among the best of currently available models. In addition, scalar coupling constants derived from simulations in the TIP4P-Ew model show a slight improvement over those obtained using the TIP3P model. Despite the overall excellent agreement, the data suggest areas for possible improvement. PMID:19651043

  10. Analytic investigation of helicopter rotor blade appended aeroelastic devices

    NASA Technical Reports Server (NTRS)

    Bielawa, Richard L.

    1984-01-01

    Analytic evaluations of four different passive aeroelastic devices appended to helicopter rotor blades are presented. The devices consist of a passive tuned tab, a control coupled tab, an all-flying tip and a harmonic dilational airfoil tip. Each device was conceived for improving either aerodynamic performance or reducing vibratory control loads or hub shears. The evaluation was performed using a comprehensive rotor aeroelastic analysis (the G400PA code with appropriate modifications), together with data for a realistic helicopter rotor blade (the UH-60A Blackhawk), in high speed flight (90 m/s, 175 kts). The results of this study show that significant performance (L/(D sub e)) gains can be achieved with the all-flying free tip. Results from the harmonic dilational airfoil tip show the potential for moderate improvements in L/(D sub e). Finally, the results for the passive tuned tab and the control coupled tab, as configured for this study, show these devices to be impractical. Sections are included which describe the operation of each device, the required G400PA modifications, and the detailed results obtained for each device.

  11. Enhanced Performance Consistency in Nanoparticle/TIPS Pentacene-Based Organic Thin Film Transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    He, Zhengran; Xiao, Kai; Durant, William Mark

    2011-01-01

    In this study, inorganic silica nanoparticles are used to manipulate the morphology of 6,13-bis(triisopropylsilylethynyl)-pentacene (TIPS pentacene) thin films and the performance of solution-processed organic thin-film transistors (OTFTs). This approach is taken to control crystal anisotropy, which is the origin of poor consistency in TIPS pentacene based OTFT devices. Thin film active layers are produced by drop-casting mixtures of SiO{sub 2} nanoparticles and TIPS pentacene. The resultant drop-cast films yield improved morphological uniformity at {approx}10% SiO{sub 2} loading, which also leads to a 3-fold increase in average mobility and nearly 4 times reduction in the ratio of measured mobility standard deviationmore » ({mu}{sub Stdev}) to average mobility ({mu}{sub Avg}). Grazing-incidence X-ray diffraction, scanning and transmission electron microscopy as well as polarized optical microscopy are used to investigate the nanoparticle-mediated TIPS pentacene crystallization. The experimental results suggest that the SiO{sub 2} nanoparticles mostly aggregate at TIPS pentacene grain boundaries, and 10% nanoparticle concentration effectively reduces the undesirable crystal misorientation without considerably compromising TIPS pentacene crystallinity.« less

  12. Enhanced Actuator Line Simulation of a Wind Turbine by including the Conservative Load at the Blade Tip

    NASA Astrophysics Data System (ADS)

    Herraez, Ivan; Micallef, Daniel; van Kuik, Gijs A. M.; Peinke, Joachim

    2015-11-01

    At the tip of wind turbine blades, the radial bound circulation is transformed into chordwise circulation just before being released as trailing vorticity, giving rise to the tip vortex. The force acting on the chordwise circulation contains a radial and a normal component with respect to the blade axis. This load does not contribute to the torque, so it is a conservative load. Due to this, it is disregarded in the engineering tools used for the design of wind turbines. However, as we demonstrated in a previous work, the conservative load might influence the trajectory of the tip vortex. In order to see how this affects the blade loads, in this research we perform large eddy simulations with an actuator line model where the conservative load has been included. The conservative load reduces the angle of attack in the tip region as a consequence of the modified tip vortex trajectory. This has a negative influence on the lift and the power output. We conclude that the accuracy of engineering design tools of wind turbines can be improved if the conservative load acting at the tip is considered.

  13. Magnet pole tips

    DOEpatents

    Thorn, Craig E.; Chasman, Chellis; Baltz, Anthony J.

    1984-04-24

    An improved magnet which more easily provides a radially increasing magnetic field, as well as reduced fringe field and requires less power for a given field intensity. The subject invention comprises a pair of spaced, opposed magnetic poles which further comprise a pair of pole roots, each having a pole tip attached to its center. The pole tips define the gap between the magnetic poles and at least a portion of each pole tip is separated from its associated pole root. The separation begins at a predetermined distance from the center of the pole root and increases with increasing radial distance while being constant with azimuth within that portion. Magnets in accordance with the subject invention have been found to be particularly advantageous for use in large isochronous cyclotrons.

  14. Magnet pole tips

    DOEpatents

    Thorn, C.E.; Chasman, C.; Baltz, A.J.

    1981-11-19

    An improved magnet more easily provides a radially increasing magnetic field, as well as reduced fringe field and requires less power for a given field intensity. The subject invention comprises a pair of spaced, opposed magnetic poles which further comprise a pair of pole roots, each having a pole tip attached to its center. The pole tips define the gap between the magnetic poles and at least a portion of each pole tip is separated from its associated pole root. The separation begins at a predetermined distance from the center of the pole root and increases with increasing radial distance while being constant with azimuth within that portion. Magnets in accordance with the subject invention have been found to be particularly advantageous for use in large isochronous cyclotrons.

  15. Control of droplet morphology for inkjet-printed TIPS-pentacene transistors

    USGS Publications Warehouse

    Lee, Myung Won; Ryu, Gi Seong; Lee, Young Uk; Pearson, Christopher; Petty, Michael C.; Song, Chung Kun

    2012-01-01

    We report on methods to control the morphology of droplets of 6,13-bis(triisopropyl-silylethynyl) pentacene (TIPS-PEN), which are then used in the fabrication of organic thin film transistors (OTFTs). The grain size and distribution of the TIPS-PEN were found to depend on the temperature of the droplets during drying. The performance of the OTFTs could be improved by heating the substrate and also by changing the relative positions of the inkjet-printed droplets. In our experiments, the optimum substrate temperature was 46 °C in air. Transistors with the TIPS-PEN grain boundaries parallel to the current flow between the source and drain electrodes exhibited charge carrier mobilities of 0.44 ± 0.08 cm2/V s.

  16. Altered Mental Status: Current Evidence-based Recommendations for Prehospital Care.

    PubMed

    Sanello, Ashley; Gausche-Hill, Marianne; Mulkerin, William; Sporer, Karl A; Brown, John F; Koenig, Kristi L; Rudnick, Eric M; Salvucci, Angelo A; Gilbert, Gregory H

    2018-05-01

    In the United States emergency medical services (EMS) protocols vary widely across jurisdictions. We sought to develop evidence-based recommendations for the prehospital evaluation and treatment of a patient with an acute change in mental status and to compare these recommendations against the current protocols used by the 33 EMS agencies in the State of California. We performed a literature review of the current evidence in the prehospital treatment of a patient with altered mental status (AMS) and augmented this review with guidelines from various national and international societies to create our evidence-based recommendations. We then compared the AMS protocols of each of the 33 EMS agencies for consistency with these recommendations. The specific protocol components that we analyzed were patient assessment, point-of-care tests, supplemental oxygen, use of standardized scoring, evaluating for causes of AMS, blood glucose evaluation, toxicological treatment, and pediatric evaluation and management. Protocols across 33 EMS agencies in California varied widely. All protocols call for a blood glucose check, 21 (64%) suggest treating adults at <60mg/dL, and half allow for the use of dextrose 10%. All the protocols recommend naloxone for signs of opioid overdose, but only 13 (39%) give specific parameters. Half the agencies (52%) recommend considering other toxicological causes of AMS, often by using the mnemonic AEIOU TIPS. Eight (24%) recommend a 12-lead electrocardiogram; others simply suggest cardiac monitoring. Fourteen (42%) advise supplemental oxygen as needed; only seven (21%) give specific parameters. In terms of considering various etiologies of AMS, 25 (76%) give instructions to consider trauma, 20 (61%) to consider stroke, and 18 (55%) to consider seizure. Twenty-three (70%) of the agencies have separate pediatric AMS protocols; others include pediatric considerations within the adult protocol. Protocols for patients with AMS vary widely across the State of California. The evidence-based recommendations that we present for the prehospital diagnosis and treatment of this condition may be useful for EMS medical directors tasked with creating and revising these protocols.

  17. Physical therapy clinic therapeutic ultrasound equipment as a source for bacterial contamination.

    PubMed

    Spratt, Henry G; Levine, David; Tillman, Larry

    2014-10-01

    A procedure commonly used in physical therapy (PT) clinics is therapeutic ultrasound (US). This equipment and associated gel comes in contact with patient skin, potentially serving as a reservoir for bacteria. In this study, we sampled US heads, gel bottle tips and gel from nine outpatient PT clinics in Southeastern Tennessee. Samples were collected using sterile swabs. At the microbiology laboratory, these swabs were used to inoculate mannitol salt agar and CHROM-MRSA agar (for Staphylococcal species) and tryptic soy broth to determine non-specific bacterial contamination. US heads, gel bottle tips and gel had variable levels of contamination. Tips of gel bottles had the highest contamination, with 52.7% positive for non-specific bacterial contamination and 3.6% positive for methicillin-resistant Staphylococcus aureus (MRSA). Contamination of gel by non-specific bacteria was found in 14.5% of bottles sampled. US heads (35.5% of those sampled) had non-specific bacterial contamination, with no MRSA detected. Disinfecting US heads after initial swabbing resulted in removal of 90.9% of non-specific contamination. Gel storage at temperatures below 40 °C was found to encourage the growth of mesophilic bacteria. This study demonstrates the need for better cleaning and storage protocols for US heads and gel bottles in PT clinics.

  18. A simple graphene-based pipette tip solid-phase extraction of malondialdehyde from human plasma and its determination by spectrofluorometry.

    PubMed

    Kaykhaii, Massoud; Yahyavi, Hossain; Hashemi, Mohammad; Khoshroo, Mohammad Reza

    2016-07-01

    Determination of malondialdehyde (MDA) in human blood plasma is important because of its role as a biomarker of lipid peroxidation in biological and medical sciences. In this work, a miniaturized graphene-based pipette tip solid-phase extraction technique was developed for very efficient extraction of MDA as its dithiobarbituric acid (TBA) adduct from human plasma. Two milligrams of graphene as sorbent were placed into a pipette tip and MDA-TBA compound was extracted and preconcentrated by it, after 4 repeated aspirating/dispensing cycles, then the column was eluted with 80 μL of dimethyl sulfoxide by 4 repeated aspirating/dispensing cycles and elusion was measured spectrofluorimetrically. Various effective parameters such as type and volume of eluent solvent, temperature, sample volume, number of cycles of extraction and desorption, derivatization reaction time, and pH of the sample solution were investigated and optimized. Under optimum conditions, a linear calibration curve was obtained in the range of 0.5-90 μg L(-1) (r (2) = 0.991) with a detection limit of 0.3 μg L(-1). The relative standard deviations for 8 replicate measurements of 10 and 40 μg L(-1) of MDA were found to be 4.51 and 3.78 % respectively. The developed protocol was successfully applied to the determination of MDA in a human blood plasma sample. Graphical Abstract A simple graphene-based pipette tip solid-phase extraction of malondialdehyde from human plasma and its determination by spectrofluorometry.

  19. Elimination of PPV and PNRSV through thermotherapy and meristem-tip culture in nectarine.

    PubMed

    Manganaris, G A; Economou, A S; Boubourakas, I N; Katis, N I

    2003-10-01

    The plum pox virus (PPV) and prunus necrotic ringspot virus (PNRSV) cause serious disease problems in stone-fruit trees. In this work, the possibility of obtaining plant material free from these viruses through thermotherapy and meristem-tip culture from infected nectarine shoots (Prunus persica var. nectarina Max, cv. 'Arm King') was studied. In addition, the detection of these viruses in in vitro cultures and young acclimatized plantlets with double antibody sandwich-enzyme-linked immunosorbent assay (DAS-ELISA) and multiplex reverse transcriptase-polymerase chain reaction (RT-PCR) was studied. Meristem-tip explants (0.8-1.3 mm) derived from sprouted buds of winter wood and spring shoots from field grown plants had a 2-5% regeneration response. However, application of thermotherapy to potted nectarine trees (3 weeks at a maximum temperature of 35 degrees C) facilitated excision of longer meristem tips (1.3-2.0 mm) that resulted in a significantly higher regeneration response (38%) in woody plant medium (WPM) without plant growth regulators. Such explants formed multiple shoots with the addition of 8 microM benzylaminopurine and 0.8 microM indoleacetic acid. When they were tested for the presence of PPV and PNRSV, 86% and 81% were found to be virus-free as detected by DAS-ELISA and multiplex RT-PCR, respectively. Individual shoots excised from virus-free cultures readily rooted in vitro (half-strength WPM plus 2 microM indolebutyric acid) and grew to plantlets. The combination of an efficient protocol for virus elimination and the establishment of highly sensitive diagnostics resulted in the production of nectarine plants free from PPV and PNRSV.

  20. The TacTip Family: Soft Optical Tactile Sensors with 3D-Printed Biomimetic Morphologies

    PubMed Central

    Pestell, Nicholas; Cramphorn, Luke; Winstone, Benjamin; Giannaccini, Maria Elena; Rossiter, Jonathan; Lepora, Nathan F.

    2018-01-01

    Abstract Tactile sensing is an essential component in human–robot interaction and object manipulation. Soft sensors allow for safe interaction and improved gripping performance. Here we present the TacTip family of sensors: a range of soft optical tactile sensors with various morphologies fabricated through dual-material 3D printing. All of these sensors are inspired by the same biomimetic design principle: transducing deformation of the sensing surface via movement of pins analogous to the function of intermediate ridges within the human fingertip. The performance of the TacTip, TacTip-GR2, TacTip-M2, and TacCylinder sensors is here evaluated and shown to attain submillimeter accuracy on a rolling cylinder task, representing greater than 10-fold super-resolved acuity. A version of the TacTip sensor has also been open-sourced, enabling other laboratories to adopt it as a platform for tactile sensing and manipulation research. These sensors are suitable for real-world applications in tactile perception, exploration, and manipulation, and will enable further research and innovation in the field of soft tactile sensing. PMID:29297773

  1. The TacTip Family: Soft Optical Tactile Sensors with 3D-Printed Biomimetic Morphologies.

    PubMed

    Ward-Cherrier, Benjamin; Pestell, Nicholas; Cramphorn, Luke; Winstone, Benjamin; Giannaccini, Maria Elena; Rossiter, Jonathan; Lepora, Nathan F

    2018-04-01

    Tactile sensing is an essential component in human-robot interaction and object manipulation. Soft sensors allow for safe interaction and improved gripping performance. Here we present the TacTip family of sensors: a range of soft optical tactile sensors with various morphologies fabricated through dual-material 3D printing. All of these sensors are inspired by the same biomimetic design principle: transducing deformation of the sensing surface via movement of pins analogous to the function of intermediate ridges within the human fingertip. The performance of the TacTip, TacTip-GR2, TacTip-M2, and TacCylinder sensors is here evaluated and shown to attain submillimeter accuracy on a rolling cylinder task, representing greater than 10-fold super-resolved acuity. A version of the TacTip sensor has also been open-sourced, enabling other laboratories to adopt it as a platform for tactile sensing and manipulation research. These sensors are suitable for real-world applications in tactile perception, exploration, and manipulation, and will enable further research and innovation in the field of soft tactile sensing.

  2. Sensing mode atomic force microscope

    DOEpatents

    Hough, Paul V. C.; Wang, Chengpu

    2003-01-01

    An atomic force microscope utilizes a pulse release system and improved method of operation to minimize contact forces between a probe tip affixed to a flexible cantilever and a specimen being measured. The pulse release system includes a magnetic particle affixed proximate the probe tip and an electromagnetic coil. When energized, the electromagnetic coil generates a magnetic field which applies a driving force on the magnetic particle sufficient to overcome adhesive forces exhibited between the probe tip and specimen. The atomic force microscope includes two independently displaceable piezo elements operable along a Z-axis. A controller drives the first Z-axis piezo element to provide a controlled approach between the probe tip and specimen up to a point of contact between the probe tip and specimen. The controller then drives the first Z-axis piezo element to withdraw the cantilever from the specimen. The controller also activates the pulse release system which drives the probe tip away from the specimen during withdrawal. Following withdrawal, the controller adjusts the height of the second Z-axis piezo element to maintain a substantially constant approach distance between successive samples.

  3. Integration of thermal digital 3D model and a MASW (Multichannel Analysis of Surface Wave) as a means of improving monitoring of spoil tip stability

    NASA Astrophysics Data System (ADS)

    Lewińska, Paulina; Matuła, Rafał; Dyczko, Artur

    2018-01-01

    Spoil tips are anthropogenic terrain structures built of leftover (coal) mining materials. They consist mostly of slate and sandstone or mudstone but also include coal and highly explosive coal dust. Coal soil tip fires cause an irreversible degradation to the environment. Government organizations notice the potential problem of spoil tip hazard and are looking for ways of fast monitoring of their temperature and inside structure. In order to test new monitoring methods an experimental was performed in the area of spoil tip of Lubelski Węgiel "Bogdanka" S.A. A survey consisted of creating a 3D discreet thermal model. This was done in order to look for potential fire areas. MASW (Multichannel analysis of surface wave) was done in order to find potential voids within the body of a tip. Existing data was digitalized and a 3D model of object's outside and inside was produced. This article provides results of this survey and informs about advantages of such an approach.

  4. High-tip-speed, low-loading transonic fan stage. Part 3: Final report

    NASA Technical Reports Server (NTRS)

    Ware, T. C.; Kobayashi, R. J.; Jackson, R. J.

    1974-01-01

    Tests were conducted on a high-tip-speed, low-loading transonic fan stage to determine the performance and inlet flow distortion tolerance of the design. The fan was designed for high efficiency at a moderate pressure ratio by designing the hub section to operate at minimum loss when the tip operates with an oblique shock. The design objective was an efficiency of 86 percent at a pressure ratio of 1.5, a specific flow (flow per unit annulus area) of 42 lb/sec-sq. ft (205.1 kgm/sec-m sq), and a tip speed of 1600 ft/sec (488.6 m/sec). During testing, a peak efficiency of 84 percent was achieved at design speed and design specific flow. At the design speed and pressure ratio, the flow was 4 percent greater than design, efficiency was 81 percent, and a stall margin of 24 percent was obtained. The stall line was improved with hub radial distortion but was reduced when the stage was tested with tip radial and circumferential flow distortions. Blade-to-blade values of static pressures were measured over the rotor blade tips.

  5. Novel cylindrical illuminator tip for ultraviolet light delivery

    NASA Astrophysics Data System (ADS)

    Shangguan, HanQun; Haw, Thomas E.; Gregory, Kenton W.; Casperson, Lee W.

    1993-06-01

    The design, processing, and sequential testing of a novel cylindrical diffusing optical fiber tip for ultraviolet light delivery is described. This device has been shown to uniformly (+/- 15%) illuminate angioplasty balloons, 20 mm in length, that are used in an experimental photochemotherapeutic treatment of swine intimal hyperplasia. Our experiments show that uniform diffusing tips of < 400 micron diameter can be reliably constructed for this and other interstitial applications. Modeling results indicate that this design is scalable to smaller diameters. The diffusing tips are made by stripping the protective buffer and etching away the cladding over a length of 20 mm from the fiber tip and replacing it with a thin layer of optical epoxy mixed with Al2O3 powder. To improve the uniformity and ease of fabrication, we have evaluated a new device configuration where the tip is etched into a modified conical shape, and the distal end face is polished and then coated with an optically opaque epoxy. This is shown to uniformly scatter approximately 70% of the light launched into the fiber without forward transmission.

  6. Reading Tips for Parents = Consejos practicos de lectura para los padre.

    ERIC Educational Resources Information Center

    Department of Education, Washington, DC. Office of Intergovernmental and Interagency Affairs.

    This booklet for parents, in both English and Spanish, offers suggestions for helping their young children develop and improve their reading skills. The booklet first presents tips for helping infants or preschoolers be ready to read and ready to learn. Suggestions include talking to the infant or toddler, reading aloud starting at 6 months,…

  7. Two for One: Using QAR to Increase Reading Comprehension and Improve Test Scores

    ERIC Educational Resources Information Center

    Green, Susan

    2016-01-01

    This teaching tip describes an intervention used in a third-grade classroom implemented to help students pass an end-of-grade reading comprehension test. Low scores on a practice end-of-grade comprehension test prompted a re-examination of classroom reading instruction and a plan for intervention. This teaching tip describes the phases implemented…

  8. Cyclic Nucleotide-gated Channel α-3 (CNGA3) Interacts with Stereocilia Tip-Link Cadherin 23 + Exon 68 or Alternatively with Myosin VIIa, Two Proteins Required for Hair Cell Mechanotransduction*

    PubMed Central

    Selvakumar, Dakshnamurthy; Drescher, Marian J.; Drescher, Dennis G.

    2013-01-01

    Previously, we obtained evidence for a photoreceptor/olfactory type of CNGA3 transcript in a purified teleost vestibular hair cell preparation with immunolocalization of CNGA3 protein to stereocilia of teleost vestibular and mammalian cochlear hair cells. The carboxyl terminus of highly Ca2+-permeable CNGA3 expressed in the mammalian organ of Corti and saccular hair cells was found to interact with an intracellular domain of microfibril interface-located protein 1 (EMILIN 1), a member of the elastin superfamily, also immunolocalizd to hair cell stereocilia (Selvakumar, D., Drescher, M. J., Dowdall, J. R., Khan, K. M., Hatfield, J. S., Ramakrishnan, N. A., and Drescher, D. G. (2012) Biochem. J. 443, 463–476). Here, we provide evidence for organ of Corti proteins, of Ca2+-dependent binding of the amino terminus of CNGA3 specifically to the carboxyl terminus of stereocilia tip-link protein CDH23 +68 (cadherin 23 with expressed exon 68) by yeast two-hybrid mating and co-transformation protocols, pulldown assays, and surface plasmon resonance analysis. Myosin VIIa, required for adaptation of hair cell mechanotransduction (MET) channel(s), competed with CDH23 +68, with direct Ca2+-dependent binding to the amino terminus of CNGA3. Based upon the premise that hair cell stereocilia tip-link proteins are closely coupled with MET, these results are consistent with the possibility that CNGA3 participates in hair-cell MET. Together with the demonstration of protein-protein interaction between HCN1 and tip-link protein protocadherin 15 CD3 (Ramakrishnan, N. A., Drescher, M. J., Barretto, R. L., Beisel, K. W., Hatfield, J. S., and Drescher, D. G. (2009) J. Biol. Chem. 284, 3227–3238; Ramakrishnan, N. A., Drescher, M. J., Khan, K. M., Hatfield, J. S., and Drescher, D. G. (2012) J. Biol. Chem. 287, 37628–37646), a protein-protein interaction for CNGA3 and a second tip-link protein, CDH23 +68, further suggests possible association of two different channels with a single stereocilia tip link. PMID:23329832

  9. Cyclic nucleotide-gated channel α-3 (CNGA3) interacts with stereocilia tip-link cadherin 23 + exon 68 or alternatively with myosin VIIa, two proteins required for hair cell mechanotransduction.

    PubMed

    Selvakumar, Dakshnamurthy; Drescher, Marian J; Drescher, Dennis G

    2013-03-08

    Previously, we obtained evidence for a photoreceptor/olfactory type of CNGA3 transcript in a purified teleost vestibular hair cell preparation with immunolocalization of CNGA3 protein to stereocilia of teleost vestibular and mammalian cochlear hair cells. The carboxyl terminus of highly Ca(2+)-permeable CNGA3 expressed in the mammalian organ of Corti and saccular hair cells was found to interact with an intracellular domain of microfibril interface-located protein 1 (EMILIN 1), a member of the elastin superfamily, also immunolocalizd to hair cell stereocilia (Selvakumar, D., Drescher, M. J., Dowdall, J. R., Khan, K. M., Hatfield, J. S., Ramakrishnan, N. A., and Drescher, D. G. (2012) Biochem. J. 443, 463-476). Here, we provide evidence for organ of Corti proteins, of Ca(2+)-dependent binding of the amino terminus of CNGA3 specifically to the carboxyl terminus of stereocilia tip-link protein CDH23 +68 (cadherin 23 with expressed exon 68) by yeast two-hybrid mating and co-transformation protocols, pulldown assays, and surface plasmon resonance analysis. Myosin VIIa, required for adaptation of hair cell mechanotransduction (MET) channel(s), competed with CDH23 +68, with direct Ca(2+)-dependent binding to the amino terminus of CNGA3. Based upon the premise that hair cell stereocilia tip-link proteins are closely coupled with MET, these results are consistent with the possibility that CNGA3 participates in hair-cell MET. Together with the demonstration of protein-protein interaction between HCN1 and tip-link protein protocadherin 15 CD3 (Ramakrishnan, N. A., Drescher, M. J., Barretto, R. L., Beisel, K. W., Hatfield, J. S., and Drescher, D. G. (2009) J. Biol. Chem. 284, 3227-3238; Ramakrishnan, N. A., Drescher, M. J., Khan, K. M., Hatfield, J. S., and Drescher, D. G. (2012) J. Biol. Chem. 287, 37628-37646), a protein-protein interaction for CNGA3 and a second tip-link protein, CDH23 +68, further suggests possible association of two different channels with a single stereocilia tip link.

  10. Joint design of large-tip-angle parallel RF pulses and blipped gradient trajectories.

    PubMed

    Cao, Zhipeng; Donahue, Manus J; Ma, Jun; Grissom, William A

    2016-03-01

    To design multichannel large-tip-angle kT-points and spokes radiofrequency (RF) pulses and gradient waveforms for transmit field inhomogeneity compensation in high field magnetic resonance imaging. An algorithm to design RF subpulse weights and gradient blip areas is proposed to minimize a magnitude least-squares cost function that measures the difference between realized and desired state parameters in the spin domain, and penalizes integrated RF power. The minimization problem is solved iteratively with interleaved target phase updates, RF subpulse weights updates using the conjugate gradient method with optimal control-based derivatives, and gradient blip area updates using the conjugate gradient method. Two-channel parallel transmit simulations and experiments were conducted in phantoms and human subjects at 7 T to demonstrate the method and compare it to small-tip-angle-designed pulses and circularly polarized excitations. The proposed algorithm designed more homogeneous and accurate 180° inversion and refocusing pulses than other methods. It also designed large-tip-angle pulses on multiple frequency bands with independent and joint phase relaxation. Pulses designed by the method improved specificity and contrast-to-noise ratio in a finger-tapping spin echo blood oxygen level dependent functional magnetic resonance imaging study, compared with circularly polarized mode refocusing. A joint RF and gradient waveform design algorithm was proposed and validated to improve large-tip-angle inversion and refocusing at ultrahigh field. © 2015 Wiley Periodicals, Inc.

  11. Identification of a novel promoter from banana aquaporin family gene (MaTIP1;2) which responses to drought and salt-stress in transgenic Arabidopsis thaliana.

    PubMed

    Song, Shun; Xu, Yi; Huang, Dongmei; Miao, Hongxia; Liu, Juhua; Jia, Caihong; Hu, Wei; Valarezo, Ana Valeria; Xu, Biyu; Jin, Zhiqiang

    2018-07-01

    Drought and salt stresses often affect plant growth and crop yields. Identification of promoters involved in drought and salt stress responses is of great significance for genetic improvement of crop resistance. Our previous studies showed that aquaporin can respond to drought and salt stresses, but its promoter has not yet been reported in plants. In the present study, cis-acting elements of MaAQP family member promoters were systematically analyzed in banana. Expression of MaTIP1; 2 was induced by drought and salt stresses but not sensitive to cold stress, waterlogging stress, or mechanical damage, and its promoter contained five stress-related cis-acting elements. The MaTIP1; 2 promoter (841 bp upstream of translation initiation site) from banana (Musa acuminata L. AAA group cv. Brazilian) was isolated through genome walking polymerase chain reaction, and found to contain a TATA Box, CAAT box, ABRE element, CCGTCC box, CGTCA motif, and TCA element. Transformation of the MaTIP1; 2 promoter into Arabidopsis to assess its function indicated that it responds to both drought and salt stress treatments. These results suggest that MaTIP1; 2 utilization may improve drought and salt stresses resistance of the transgenic plants by promoting banana aquaporin expression. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  12. Intravascular Ultrasound Guidance for Transjugular Intrahepatic Portosystemic Shunt Procedure in a Swine Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kew, Jacqueline; Davies, Roger P.

    2004-01-15

    A new method is described for guiding hepato-portalvenous puncture using a longitudinal side-view intravascular ultrasound(L-IVUS) transducer to assist in the performance of transjugularintrahepatic portosystemic shunt (TIPS) in three Australian swine.Simultaneous L-IVUS with an AcuNav (registered) 5-10 MHz 10 Fr transducer(Acuson Corporation, Mountain View, CA, USA) and fluoroscopy guidance was used to image and monitor the hepatic to portal venous puncture,dilatation of the tract, and deployment of the TIPS stent. Flow through the shunt could be demonstrated with both L-IVUS and angiography. TIPS was successful in all swine. The time for portal vein puncture once the target portal vein was identifiedmore » was reduced at each attempt. The number of portal vein puncture attempts was 2, 1, and 1. No post-procedural complication was evident. L-IVUS-guided TIPS is practical and has the potential to improve safety by permitting simultaneous ultrasound and fluoroscopic imaging of the needle and target vascular structures. This technique allows for a more streamlined approach to TIPS, decreasing the fluoroscopic time (hence,decreasing the radiation exposure to the staff and patient) and anesthetic time. In addition, there are improved safety benefits obviating the need for wedged portography, facilitating avoidance of bile duct and hepatic arterial puncture, and minimizing hepatic injury by decreasing liver capsular puncture and the attendant risks.« less

  13. Clinically Practical Magnetic Resonance Protocol for Improved Specificity in Breast Cancer Diagnosis

    DTIC Science & Technology

    2007-06-01

    Protocol for Improved Specificity in Breast Cancer Diagnosis PRINCIPAL INVESTIGATOR: Luminita Alina Tudorica, Ph.D. CONTRACTING...TITLE AND SUBTITLE 5a. CONTRACT NUMBER Clinically Practical Magnetic Resonance Protocol for Improved Specificity in Breast Cancer Diagnosis 5b... breast cancer study in a clinical setting. This study aims to improve specificity of breast cancer detection by using a combined MRI/MRS protocol. In

  14. Numerical investigation of the unsteady tip leakage flow and rotating stall inception in a transonic compressor

    NASA Astrophysics Data System (ADS)

    Zhang, Yanfeng; Lu, Xingen; Chu, Wuli; Zhu, Junqiang

    2010-08-01

    It is well known that tip leakage flow has a strong effect on the compressor performance and stability. This paper reports on a numerical investigation of detailed flow structures in an isolated transonic compressor rotor-NASA Rotor 37 at near stall and stalled conditions aimed at improving understanding of changes in 3D tip leakage flow structures with rotating stall inception. Steady and unsteady 3D Navier-Stokes analyses were conducted to investigate flow structures in the same rotor. For steady analysis, the predicted results agree well with the experimental data for the estimation of compressor rotor global performance. For unsteady flow analysis, the unsteady flow nature caused by the breakdown of the tip leakage vortex in blade tip region in the transonic compressor rotor at near stall condition has been captured with a single blade passage. On the other hand, the time-accurate unsteady computations of multi-blade passage at near stall condition indicate that the unsteady breakdown of the tip leakage vortex triggered the short length-scale — spike type rotating stall inception at blade tip region. It was the forward spillage of the tip leakage flow at blade leading edge resulting in the spike stall inception. As the mass flow ratio is decreased, the rotating stall cell was further developed in the blade passage.

  15. High-speed microprobe for roughness measurements in high-aspect-ratio microstructures

    NASA Astrophysics Data System (ADS)

    Doering, Lutz; Brand, Uwe; Bütefisch, Sebastian; Ahbe, Thomas; Weimann, Thomas; Peiner, Erwin; Frank, Thomas

    2017-03-01

    Cantilever-type silicon microprobes with an integrated tip and a piezoresistive signal read out have successfully proven to bridge the gap between scanning force microscopy and stylus profilometry. Roughness measurements in high-aspect-ratio microstructures (HARMS) with depths down to 5 mm and widths down to 50 µm have been demonstrated. To improve the scanning speed up to 15 mm s-1, the wear of the tip has to be reduced. The atomic layer deposition (ALD) technique with alumina (Al2O3) has been tested for this purpose. Repeated wear measurements with coated and uncoated microprobe cantilevers have been carried out on a roughness standard at a speed of 15 mm s-1. The tip shape and the wear have been measured using a new probing tip reference standard containing rectangular silicon grooves with widths from 0.3 µm to 3 µm. The penetration depth of the microprobe allows one to measure the wear of the tip as well as the tip width and the opening angle of the tip. The roughness parameters obtained on the roughness standard during wear experiments agree well with the reference values measured with a calibrated stylus instrument, nevertheless a small amount of wear still is observable. Further research is necessary in order to obtain wear resistant microprobe tips for non-destructive inspection of microstructures in industry and microform measurements, for example in injection nozzles.

  16. Influence of tip end-plate on noise of small axial fan

    NASA Astrophysics Data System (ADS)

    Mao, Hongya; Wang, Yanping; Lin, Peifeng; Jin, Yingzi; Setoguchi, Toshiaki; Kim, Heuy Dong

    2017-02-01

    In this work, tip end-plate is used to improve the noise performance of small axial fans. Both numerical simulations and experimental methods were adopted to study the fluid flow and noise level of axial fans. Four modified models and the prototype are simulated. Influences of tip end-plate on static characteristics, internal flow field and noise of small axial fans are analyzed. The results show that on basis of the prototype, the model with the tip end-plate of 2 mm width and changed length achieved best noise performance. The overall sound pressure level of the model with the tip end-plate of 2 mm width and changed length is 2.4 dB less than that of the prototype at the monitoring point in specified far field. It is found that the mechanism of noise reduction is due to the decrease of vorticity variation on the surface of blades caused by the tip end-plate. Compared with the prototype, the static pressure of the model with the tip end-plate of 2 mm width and changed length at design flow rate decreases by 2 Pa and the efficiency decreases by 0.8%. It is concluded that the method of adding tip end-plate to impeller blades has a positive influence on reducing noise, but it may diminish the static characteristics of small axial fan to some extent.

  17. Cryptanalysis and Improvement of the Semi-quantum Secret Sharing Protocol

    NASA Astrophysics Data System (ADS)

    Gao, Xiang; Zhang, Shibin; Chang, Yan

    2017-08-01

    Recently, Xie et al. Int. J. Theor. Phys. 54, 3819-3824, (2015) proposed a Semi-quantum secret sharing protocol (SQSS). Yin et al. Int. J. Theor. Phys. 55: 4027-4035, (2016) pointed out that this protocol suffers from the intercept-resend attack. Yin et al. also proposed an improved protocol. However, we find out that Yin et al.'s paper has some problems, we analyze Yin et al.'s paper, then proposed the improved semi-quantum secret sharing protocol. Our protocol is more secure and efficient, most importantly, our protocol satisfies the condition of semi-quantum.

  18. Multi-Hop Teleportation of an Unknown Qubit State Based on W States

    NASA Astrophysics Data System (ADS)

    Zhou, Xiang-Zhen; Yu, Xu-Tao; Zhang, Zai-Chen

    2018-04-01

    Quantum teleportation is important in quantum communication networks. Considering that quantum state information is also transmitted between two distant nodes, intermediated nodes are employed and two multi-hop teleportation protocols based on W state are proposed. One is hop-by-hop teleportation protocol and the other is the improved multi-hop teleportation protocol with centralized unitary transformation. In hop-by-hop protocol, the transmitted quantum state needs to be recovered at every node on the route. In improved multi-hop teleportation protocol with centralized unitary transformation, intermediate nodes need not to recover the transmitted quantum state. Compared to the hop-by-hop protocol, the improved protocol can reduce the transmission delay and improve the transmission efficiency.

  19. TIP: protein backtranslation aided by genetic algorithms.

    PubMed

    Moreira, Andrés; Maass, Alejandro

    2004-09-01

    Several applications require the backtranslation of a protein sequence into a nucleic acid sequence. The degeneracy of the genetic code makes this process ambiguous; moreover, not every translation is equally viable. The usual answer is to mimic the codon usage of the target species; however, this does not capture all the relevant features of the 'genomic styles' from different taxa. The program TIP ' Traducción Inversa de Proteínas') applies genetic algorithms to improve the backtranslation, by minimizing the difference of some coding statistics with respect to their average value in the target. http://www.cmm.uchile.cl/genoma/tip/

  20. Thermal characterization assessment of rigid and flexible water models in a nanogap using molecular dynamics

    NASA Astrophysics Data System (ADS)

    Akıner, Tolga; Mason, Jeremy; Ertürk, Hakan

    2017-11-01

    The thermal properties of the TIP3P and TIP5P water models are investigated using equilibrium and non-equilibrium molecular dynamics techniques in the presence of solid surfaces. The performance of the non-equilibrium technique for rigid molecules is found to depend significantly on the distribution of atomic degrees of freedom. An improved approach to distribute atomic degrees of freedom is proposed for which the thermal conductivity of the TIP5P model agrees more closely with equilibrium molecular dynamics and experimental results than the existing state of the art.

  1. Transjugular Intrahepatic Porto-Systemic Shunt in Patients with Liver Cirrhosis and Model for End-Stage Liver Disease ≥15.

    PubMed

    Ascha, Mona; Hanouneh, Mohamad; S Ascha, Mustafa; Zein, Nizar N; Sands, Mark; Lopez, Rocio; Hanouneh, Ibrahim A

    2017-02-01

    It is not known whether transjugular intrahepatic porto-systemic shunt (TIPS) is safe in patients with advanced liver cirrhosis. The aim of our study was to evaluate the impact of TIPS on transplant-free survival in patients with liver cirrhosis and MELD score ≥15. All adult patients who underwent TIPS at our institution between 2004 and 2011 were identified (N = 470). A total of 144 patients had MELD ≥15 at the time of TIPS. These patients were matched 1:1 to patients with liver cirrhosis who did not undergo TIPS based on age and MELD score using the greedy algorithm. Patients were followed up until time of death or liver transplantation. Kaplan-Meier curves and log-rank tests were used to test for differences in survival outcome between the two groups. A total of 288 patients with liver cirrhosis were included, of whom 144 underwent TIPS and 144 did not. The two groups were matched based on age and MELD score and were comparable with regard to gender and ethnicity. Mean MELD and Child-Pugh scores in the study population were 20.9 ± 6.5 and 10.5 ± 1.8, respectively. The most common indication for TIPS was varices (49 %), followed by refractory ascites (42 %). In the first 2 months post-TIPS, there was increased mortality or liver transplantation in patients who had TIPS compared to those who did not, but this did not reach statistical significance (p = 0.07). However, after 2 months, TIPS is associated with 56 % lower risk of dying or needing liver transplantation (p < 0.01) than cirrhotic patients who did not undergo TIPS. In patients with liver cirrhosis and MELD ≥15, TIPS might improve transplant-free survival for patients who live for at least 2 months after the procedure.

  2. In Vitro Conservation of Date Palm Shoot-Tip Explants and Callus Cultures Under Minimal Growth Conditions.

    PubMed

    El-Dawayati, Maiada M

    2017-01-01

    Date palm fruit production has great economic significance for many countries. There is a fundamental necessity to conserve valuable date palm germplasm, but there are various problems with in vivo and ex situ conservation. In vitro storage has several advantages over conventional germplasm conservation methods. The in vitro technique offers a developed method of slow-growth storage, which is considered as an alternate solution for short- and medium-term storage of date palm germplasm under controlled conditions. Minimal growth conditions for germplasm conservation are generally achieved by reducing growth rate through modification of environmental growing conditions and culture, by using low temperatures, and the addition of growth retardants and osmotic agents. This chapter describes a protocol for short-term in vitro conservation of date palm shoot-tip and callus cultures under slow-growth storage conditions, using sucrose as an osmotic agent and abscisic acid (ABA) as a growth retardant at 15 °C for 12 months.

  3. Tips for using mobile audience response systems in medical education

    PubMed Central

    Gousseau, Michael; Sommerfeld, Connor; Gooi, Adrian

    2016-01-01

    Background With growing evidence on the benefits of active learning, audience response systems (ARSs) have been increasingly used in conferences, business, and education. With the introduction of mobile ARS as an alternative to physical clickers, there are increasing opportunities to use this tool to improve interactivity in medical education. Aim The aim of this study is to provide strategies on using mobile ARS in medical education by discussing steps for implementation and pitfalls to avoid. Method The tips presented reflect our commentary of the literature and our experiences using mobile ARS in medical education. Results This article offers specific strategies for the preparation, implementation, and assessment of medical education teaching sessions using mobile ARS. Conclusion We hope these tips will help instructors use mobile ARS as a tool to improve student interaction, teaching effectiveness, and participant enjoyment in medical education. PMID:27942242

  4. Morphology of Er:YAG-laser-treated root surfaces

    NASA Astrophysics Data System (ADS)

    Keller, Ulrich; Stock, Karl; Hibst, Raimund

    1997-12-01

    From previous studies it could be demonstrated that an efficient ablation of dental calculus is possible using an Er:YAG laser with a special contact fiber tip. After improving of the design and the efficiency of light transmission of the contact tip laser treated tooth root surfaces were investigated due to morphological changes in comparison to conventional root scaling and planing. Surface modifications were observed histologically under the light microscope and by means of a Scanning Electron Microscope. During laser treatment the intrapulpal temperature increase was measured. The results show that the improved contact tip a microstructured surface can be generated, which shows no signs of thermal effects even when a laser pulse repetition rate of 15 Hz was used. Temperature increase was limited to 4 K at a repetition rate of 10 Hz and to 5.5 K at a repetition rate of 15 Hz.

  5. The Evolution of Transjugular Intrahepatic Portosystemic Shunt: Tips

    PubMed Central

    Fanelli, Fabrizio

    2014-01-01

    Since Richter's description in the literature in 1989 of the first procedure on human patients, transjugular intrahepatic portosystemic shunt (TIPS) has been worldwide considered as a noninvasive technique to manage portal hypertension complications. TIPS succeeds in lowering the hepatic sinusoidal pressure and in increasing the circulatory flow, thus reducing sodium retention, ascites recurrence, and variceal bleeding. Required several revisions of the shunt TIPS can be performed in case of different conditions such as hepatorenal syndrome, hepatichydrothorax, portal vein thrombosis, and Budd-Chiari syndrome. Most of the previous studies on TIPS procedure were based on the use of bare stents and most patients chose TIPS 2-3 years after traditional treatment, thus making TIPS appear to be not superior to endoscopy in survival rates. Bare stents were associated with higher incidence of shunt failure and consequently patients required several revisions during the follow-up. With the introduction of a dedicated e-PTFE covered stent-graft, these problems were completely solved, No more reinterventions are required with a tremendous improvement of patient's quality of life. One of the main drawbacks of the use of e-PTFE covered stent-graft is higher incidence of hepatic encephalopathy. In those cases refractory to the conventional medical therapy, a shunt reduction must be performed. PMID:27335841

  6. Rational design and validation of a Tip60 histone acetyltransferase inhibitor

    NASA Astrophysics Data System (ADS)

    Gao, Chunxia; Bourke, Emer; Scobie, Martin; Famme, Melina Arcos; Koolmeister, Tobias; Helleday, Thomas; Eriksson, Leif A.; Lowndes, Noel F.; Brown, James A. L.

    2014-06-01

    Histone acetylation is required for many aspects of gene regulation, genome maintenance and metabolism and dysfunctional acetylation is implicated in numerous diseases, including cancer. Acetylation is regulated by histone acetyltransferases (HATs) and histone deacetylases and currently, few general HAT inhibitors have been described. We identified the HAT Tip60 as an excellent candidate for targeted drug development, as Tip60 is a key mediator of the DNA damage response and transcriptional co-activator. Our modeling of Tip60 indicated that the active binding pocket possesses opposite charges at each end, with the positive charges attributed to two specific side chains. We used structure based drug design to develop a novel Tip60 inhibitor, TH1834, to fit this specific pocket. We demonstrate that TH1834 significantly inhibits Tip60 activity in vitro and treating cells with TH1834 results in apoptosis and increased unrepaired DNA damage (following ionizing radiation treatment) in breast cancer but not control cell lines. Furthermore, TH1834 did not affect the activity of related HAT MOF, as indicated by H4K16Ac, demonstrating specificity. The modeling and validation of the small molecule inhibitor TH1834 represents a first step towards developing additional specific, targeted inhibitors of Tip60 that may lead to further improvements in the treatment of breast cancer.

  7. Parallel transjugular intrahepatic portosystemic shunt for controlling portal hypertension complications in cirrhotic patients.

    PubMed

    He, Fu-Liang; Wang, Lei; Yue, Zhen-Dong; Zhao, Hong-Wei; Liu, Fu-Quan

    2014-09-07

    To evaluate the feasibility of a second parallel transjugular intrahepatic portosystemic shunt (TIPS) to reduce portal venous pressure and control complications of portal hypertension. From January 2011 to December 2012, 10 cirrhotic patients were treated for complications of portal hypertension. The demographic data, operative data, postoperative recovery data, hemodynamic data, and complications were analyzed. Ten patients underwent a primary and parallel TIPS. Technical success rate was 100% with no technical complications. The mean duration of the first operation was 89.20 ± 29.46 min and the second operation was 57.0 ± 12.99 min. The mean portal system pressure decreased from 54.80 ± 4.16 mmHg to 39.0 ± 3.20 mmHg after the primary TIPS and from 44.40 ± 3.95 mmHg to 26.10 ± 4.07 mmHg after the parallel TIPS creation. The mean portosystemic pressure gradient decreased from 43.80 ± 6.18 mmHg to 31.90 ± 2.85 mmHg after the primary TIPS and from 35.60 ± 2.72 mmHg to 15.30 ± 3.27 mmHg after the parallel TIPS creation. Clinical improvement was seen in all patients after the parallel TIPS creation. One patient suffered from transient grade I hepatic encephalopathy (HE) after the primary TIPS and four patients experienced transient grade I-II after the parallel TIPS procedure. Mean hospital stay after the first and second operations were 15.0 ± 3.71 d and 16.90 ± 5.11 d (P = 0.014), respectively. After a mean 14.0 ± 3.13 mo follow-up, ascites and bleeding were well controlled and no stenosis of the stents was found. Parallel TIPS is an effective approach for controlling portal hypertension complications.

  8. Video Laryngoscopic Techniques Associated with Intubation Success in a Helicopter Emergency Medical Service System.

    PubMed

    Naito, Hiromichi; Guyette, Francis X; Martin-Gill, Christian; Callaway, Clifton W

    2016-01-01

    Video laryngoscopy (VL) is a technical adjunct to facilitate endotracheal intubation (ETI). VL also provides objective data for training and quality improvement, allowing evaluation of the technique and airway conditions during ETI. Previous studies of factors associated with ETI success or failure are limited by insufficient nomenclature, individual recall bias and self-report. We tested whether the covariates in prehospital VL recorded data were associated with ETI success. We also measured association between time and clinical variables. Retrospective review was conducted in a non-physician staffed helicopter emergency medical service system. ETI was typically performed using sedation and neuromuscular-blockade under protocolized orders. We obtained process and outcome variables from digitally recorded VL data. Patient characteristics data were also obtained from the emergency medical service record and linked to the VL recorded data. The primary outcome was to identify VL covariates associated with successful ETI attempts. Among 304 VL recorded ETI attempts in 268 patients, ETI succeeded for 244 attempts and failed for 60 attempts (first-pass success rate, 82% and overall success rate, 94%). Laryngoscope blade tip usually moved from a shallow position in the oropharynx to the vallecula. In the multivariable logistic regression analysis, attempt time (p = 0.02; odds ratio [OR] 0.99), Cormack-Lehane view (p < 0.001; OR 0.23), bodily fluids obstructing the view (p = 0.01; OR 0.29), and VL equipment failure (p < 0.001; OR 0.14) were negatively associated with successful attempts. Bodily fluids obstructing the view (p < 0.001; hazard ratio [HR] 0.51), VL equipment failure (p = 0.003; HR 0.42), shallow placement of blade tip within 4 seconds (p < 0.001; HR 0.40), number of forward movements (p < 0.001; HR 0.84), trauma (p = 0.04; HR 0.65), and neurological diagnosis (p = 0.04; HR 0.60) were associated with longer ETI attempt time. Bodily fluids obstructing the view, equipment problems, higher Cormack-Lehane view, and longer ETI attempt time were negatively associated with successful ETI attempts. Initially shallow blade tip position may associate with longer ETI time. VL is useful for measuring and describing multiple factors of ETI and can provide valuable data.

  9. Fiber-optic Singlet Oxygen [1O2 (1Δg)] Generator Device Serving as a Point Selective Sterilizer

    PubMed Central

    Aebisher, David; Zamadar, Matibur; Mahendran, Adaickapillai; Ghosh, Goutam; McEntee, Catherine; Greer, Alexander

    2016-01-01

    Traditionally, Type II heterogeneous photo-oxidations produce singlet oxygen via external irradiation of a sensitizer and external supply of ground-state oxygen. A potential improvement is reported here. A hollow-core fiber-optic device was developed with an “internal” supply of light and flowing oxygen, and a porous photosensitizer-end capped configuration. Singlet oxygen was delivered through the fiber tip. The singlet oxygen steady-state concentration in the immediate vicinity of the probe tip was ca 20 fM by N-benzoyl-DL-methionine trapping. The device is portable and the singlet oxygen-generating tip is maneuverable, which opened the door to simple disinfectant studies. Complete Escherichia coli inactivation was observed in 2 h when the singlet oxygen sensitizing probe tip was immersed in 0.1 mL aqueous samples of 0.1–4.4 × 107 cells. Photobleaching of the probe tip occurred after ca 12 h of use, requiring baking and sensitizer reloading steps for reuse. PMID:20497367

  10. Air-Flow Navigated Crystal Growth for TIPS Pentacene-Based Organic Thin-Film Transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    He, Zhengran; Chen, Jihua; Sun, Zhenzhong

    2012-01-01

    6,13-bis(triisopropylsilylethynyl)pentacene (TIPS pentacene) is a promising active channel material of organic thin-film transistors (OTFTs) due to its solubility, stability, and high mobility. However, the growth of TIPS pentacene crystals is intrinsically anisotropic and thus leads to significant variation in the performance of OTFTs. In this paper, air flow is utilized to effectively reduce the TIPS pentacene crystal anisotropy and enhance performance consistency in OTFTs, and the resulted films are examined with optical microscopy, grazing-incidence X-ray diffraction, and thin-film transistor measurements. Under air-flow navigation (AFN), TIPS pentacene drop-cast from toluene solution has been observed to form thin films with improved crystalmore » orientation and increased areal coverage on substrates, which subsequently lead to a four-fold increase of average hole mobility and one order of magnitude enhancement in performance consistency defined by the ratio of average mobility to the standard deviation of the field-effect mobilities.« less

  11. Turbine blade tip flow discouragers

    DOEpatents

    Bunker, Ronald Scott

    2000-01-01

    A turbine assembly comprises a plurality of rotating blade portions in a spaced relation with a stationery shroud. The rotating blade portions comprise a root section, a tip portion and an airfoil. The tip portion has a pressure side wall and a suction side wall. A number of flow discouragers are disposed on the blade tip portion. In one embodiment, the flow discouragers extend circumferentially from the pressure side wall to the suction side wall so as to be aligned generally parallel to the direction of rotation. In an alternative embodiment, the flow discouragers extend circumferentially from the pressure side wall to the suction side wall so as to be aligned at an angle in the range between about 0.degree. to about 60.degree. with respect to a reference axis aligned generally parallel to the direction of rotation. The flow discouragers increase the flow resistance and thus reduce the flow of hot gas flow leakage for a given pressure differential across the blade tip portion so as to improve overall turbine efficiency.

  12. Cryptanalysis and improvement of an improved two factor authentication protocol for telecare medical information systems.

    PubMed

    Chaudhry, Shehzad Ashraf; Naqvi, Husnain; Shon, Taeshik; Sher, Muhammad; Farash, Mohammad Sabzinejad

    2015-06-01

    Telecare medical information systems (TMIS) provides rapid and convenient health care services remotely. Efficient authentication is a prerequisite to guarantee the security and privacy of patients in TMIS. Authentication is used to verify the legality of the patients and TMIS server during remote access. Very recently Islam et al. (J. Med. Syst. 38(10):135, 2014) proposed a two factor authentication protocol for TMIS using elliptic curve cryptography (ECC) to improve Xu et al.'s (J. Med. Syst. 38(1):9994, 2014) protocol. They claimed their improved protocol to be efficient and provides all security requirements. However our analysis reveals that Islam et al.'s protocol suffers from user impersonation and server impersonation attacks. Furthermore we proposed an enhanced protocol. The proposed protocol while delivering all the virtues of Islam et al.'s protocol resists all known attacks.

  13. Fermilab Today | Tip of the Week Archive

    Science.gov Websites

    flood safety tips June 15, 2015 Why are there so many species? June 8, 2015 Cybersecurity in the 11, 2015 May is Electrical Safety Month May 4, 2015 The last line of defense is you April 27, 2015 A ? Fire! April 6, 2015 What could possibly go wrong? March 30, 2015 Improving traffic safety at Fermilab

  14. Influence of Finite Span and Sweep on Active Flow Control Efficacy

    NASA Technical Reports Server (NTRS)

    Greenblatt, David; Washburn, Anthony E.

    2008-01-01

    Active flow control efficacy was investigated by means of leading-edge and flap-shoulder zero mass-flux blowing slots on a semispan wing model that was tested in unswept (standard) and swept configurations. On the standard configuration, stall commenced inboard, but with sweep the wing stalled initially near the tip. On both configurations, leading-edge perturbations increased CL,max and post stall lift, both with and without deflected flaps. Without sweep, the effect of control was approximately uniform across the wing span but remained effective to high angles of attack near the tip; when sweep was introduced a significant effect was noted inboard, but this effect degraded along the span and produced virtually no meaningful lift enhancement near the tip, irrespective of the tip configuration. In the former case, control strengthened the wingtip vortex; in the latter case, a simple semi-empirical model, based on the trajectory or "streamline" of the evolving perturbation, served to explain the observations. In the absence of sweep, control on finite-span flaps did not differ significantly from their nominally twodimensional counterpart. Control from the flap produced expected lift enhancement and CL,max improvements in the absence of sweep, but these improvements degraded with the introduction of sweep.

  15. On the role of tip curvature on flapping plates.

    PubMed

    Martin, Nathan; Gharib, Morteza

    2018-01-09

    During the flapping motion of a fish's tail, the caudal fin exhibits antero-posterior bending and dorso-ventral bending, the latter of which is referred to as chord-wise bending herein. The impact of chord-wise tip curvature on the hydrodynamic forces for flapping plates is investigated to explore potential mechanisms to improve the maneuverability or the performance of autonomous underwater vehicles. First, actuated chord-wise tip curvature is explored. Comparison of rigid curved geometries to a rigid flat plate as a baseline suggests that an increased curvature decreases the generated forces. An actuated plate with a dynamic tip curvature is created to illustrate a modulation of this decrease in forces. Second, the impact of curvature is isolated using curved plates with an identical planform area. Comparison of rigid curved geometries as a baseline corroborates the result that an increased curvature decreases the generated forces, with the exception that presenting a concave geometry into the flow increases the thrust and the efficiency. A passively-actuated plate is designed to capitalize on this effect by presenting a concave geometry into the flow throughout the cycle. The dynamically and passively actuated plates show potential to improve the maneuverability and the efficiency of autonomous underwater vehicles, respectively.

  16. Evaluation of a novel, ultrathin, tip-bending endoscope in a synthetic force-sensing pancreas with comparison to medical guide wires

    PubMed Central

    Chandler, John E; Lee, Cameron M; Babchanik, Alexander P; Melville, C David; Saunders, Michael D; Seibel, Eric J

    2012-01-01

    Purpose Direct visualization of pancreatic ductal tissue is critical for early diagnosis of pancreatic diseases and for guiding therapeutic interventions. A novel, ultrathin (5 Fr) scanning fiber endoscope (SFE) with tip-bending capability has been developed specifically to achieve high resolution imaging as a pancreatoscope during endoscopic retrograde cholangiopancreatography (ERCP). This device has potential to dramatically improve both diagnostic and therapeutic capabilities during ERCP by providing direct video feedback and tool guidance to clinicians. Methods Invasiveness of the new tip-bending SFE was evaluated by a performance comparison to ERCP guide wires, which are routinely inserted into the pancreatic duct during ERCP. An in vitro test model with four force sensors embedded in a synthetic pancreas was designed to detect and compare the insertion forces for 0.89 mm and 0.53 mm diameter guide wires as well as the 1.7 mm diameter SFE. Insertions were performed through the working channel of a therapeutic duodenoscope for the two types of guide wires and using a statistically similar direct insertion method for comparison to the SFE. Results Analysis of the forces detected by the sensors showed the smaller diameter 0.53 mm wire produced significantly less average and maximum forces during insertion than the larger diameter 0.89 mm wire. With the use of tip-bending and optical visualization, the 1.7 mm diameter SFE produced significantly less average force during insertion than the 0.89 mm wire at every sensor, despite its larger size. It was further shown that the use of tip-bending with the SFE significantly reduced the forces at all sensors, compared to insertions when tip-bending was not used. Conclusion Combining high quality video imaging with two-axis tip-bending allows a larger diameter guide wire-style device to be inserted into the pancreatic duct during ERCP with improved capacity to perform diagnostics and therapy. PMID:23166452

  17. Method for somatic cell nuclear transfer in zebrafish.

    PubMed

    Siripattarapravat, Kannika; Cibelli, Jose B

    2011-01-01

    Somatic cell nuclear transfer (SCNT) has been a well-known technique for decades and widely applied to generate identical animals, including ones with genetic alterations. The system has been demonstrated successfully in zebrafish. The elaborated requirements of SCNT, however, limit reproducibility of the established model to a few groups in zebrafish research community. In this chapter, we meticulously outline each step of the published protocol as well as preparations of equipments and reagents used in zebrafish SCNT. All describable detailed-tips are elaborated in texts and figures. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Eavesdropping on the improved three-party quantum secret sharing protocol

    NASA Astrophysics Data System (ADS)

    Gao, Gan

    2011-02-01

    Lin et al. [Song Lin, Fei Gao, Qiao-yan Wen, Fu-chen Zhu, Opt. Commun. 281 (2008) 4553] pointed out that the multiparty quantum secret sharing protocol [Zhan-jun Zhang, Gan Gao, Xin Wang, Lian-fang Han, Shou-hua Shi, Opt. Commun. 269 (2007) 418] is not secure and proposed an improved three-party quantum secret sharing protocol. In this paper, we study the security of the improved three-party quantum secret sharing protocol and find that it is still not secure. Finally, a further improved three-party quantum secret sharing protocol is proposed.

  19. [The factors that influence the use of clinical protocols according to the opinion of health center coordinators. The Research Group on the Evaluation and Improvement of Clinical Protocols].

    PubMed

    Saura-Llamas, J; Saturno Hernández, P J; Gaona Ramón, J M; Romero Román, J R; González Barberá, M

    1999-11-15

    To find the factors that affect the use of clinical protocols in primary care, in the view of primary care team coordinators, and the reasons why they are little followed, and to bring together suggestions for improvement. An opinion study, through a telephone survey. Primary health care. The health centres in Murcia with protocolized activity: 31 at the start of the project. The coordinators and those in charge of nursing, 62 people in all. After a pilot study, a structured telephone survey was carried out, administered by a trained interviewer who posed two open questions: why do you think that the professionals at your centre do not use the existing protocols more often? and: what suggestions would you make to improve the protocols and have them used more? A specialist company did the field-work in June and July 1996. There was a 98% reply rate. To the first question, coordinators thought that low use could be explained by excess demand and lack of time for consultations (33% of all replies), although they also cited other organisational problems in the centre, defects in protocols and lack of training. Those in charge of nursing gave very similar replies, with excess demand (39%) predominating. To the second question, on increasing the use of protocols, coordinators suggested that the protocols needed to be improved (44.8% of replies), and also cited the need for improvements in organisation and on-going training. Very similar answers came from the nursing side, where 43.5% highlighted the need to improve the protocol documents. The coordinators assumed that the clinical protocols were used little and could be improved. In their view the basic reason for their low use is excessive pressure from the patient-load. The key to using them more is improvement in the protocol documents.

  20. MRI features after radiofrequency ablation of osteoid osteoma with cooled probes and impedance-control energy delivery.

    PubMed

    Cantwell, Colin P; Kerr, Jennifer; O'Byrne, John; Eustace, Stephen

    2006-05-01

    The purposes of our study were to determine the temporal changes in MR signal in bone after radiofrequency ablation of osteoid osteoma and the size of the zone of marrow signal change produced by the radiofrequency technique and to compare the size of the zone with published data for radiofrequency ablation with manual-control protocols. Radiofrequency ablation was performed in 10 patients with a clinical and radiologic diagnosis of osteoid osteoma. A cooled radiofrequency probe was inserted in the nidus. Twelve minutes of radiofrequency energy was applied from a 200-W radiofrequency generator in an impedance-control setting. MRI with multiplanar turbo spin-echo T1-weighted and STIR sequences was performed at 1, 7, and 28 days after the procedure in seven patients. The three remaining patients had follow-up imaging at 28 days only. The images were reviewed by two radiologists who categorized the imaging features and measured the marrow zone of signal alteration when visible. The size of the zone of marrow signal change produced by the radiofrequency technique was compared with published data for radiofrequency ablation with manual-control protocols. A 1-mm band of homogeneous altered marrow signal distributed symmetrically parallel to the entire probe tract was seen earliest, at 1 day, in the femoral neck lesion treated with the 2-cm probe. The band was low signal on the T1 sequence and high signal on the STIR sequence, and the diameter of the zone was 27 mm. By 7 days, five of the seven treated bones showed a band of marrow signal alteration. By 28 days, all 10 treated bones had a band of marrow signal alteration. The interband distance at 90 degrees to the probe measured on STIR images at 28 days was a mean of 20.9 mm (confidence interval, 16.1-25.7 mm [p < 0.05]; range +/- measurement error, 10.5-35 +/- 1.64 mm) with a 1-cm probe and 30.5 mm (measurement error, +/- 0.78 mm) on T1 images without contrast material when a 2-cm exposed-tip probe was used. Higher-output generators with impedance-control software and internally cooled radiofrequency probes with longer exposed tips produce larger zones of marrow signal change than expected with manual-control protocols. MRI allows detection of temporal marrow signal change after radiofrequency ablation. The marrow signal change with a high-energy delivery protocol is larger than manual-control protocols.

  1. A Numerical Analysis of Heat Transfer and Effectiveness on Film Cooled Turbine Blade Tip Models

    NASA Technical Reports Server (NTRS)

    Ameri, A. A.; Rigby, D. L.

    1999-01-01

    A computational study has been performed to predict the distribution of convective heat transfer coefficient on a simulated blade tip with cooling holes. The purpose of the examination was to assess the ability of a three-dimensional Reynolds-averaged Navier-Stokes solver to predict the rate of tip heat transfer and the distribution of cooling effectiveness. To this end, the simulation of tip clearance flow with blowing of Kim and Metzger was used. The agreement of the computed effectiveness with the data was quite good. The agreement with the heat transfer coefficient was not as good but improved away from the cooling holes. Numerical flow visualization showed that the uniformity of wetting of the surface by the film cooling jet is helped by the reverse flow due to edge separation of the main flow.

  2. System and method for improved rotor tip performance

    NASA Technical Reports Server (NTRS)

    Zientek, Thomas A. (Inventor); Bussom, Richard (Inventor); McVeigh, Michael A. (Inventor); Narducci, Robert P. (Inventor)

    2007-01-01

    The present invention discloses systems and methods for the performance enhancement of rotary wing aircraft through reduced torque, noise and vibration. In one embodiment, a system includes a sail having an aerodynamic shape positioned proximate to a tip of the rotor blade. An actuator may be configured to rotate the sail relative to the blade tip. a A control system receives information from a rotorcraft system and commands the actuator to rotate the sail to a predetermined favorable rotor blade operating condition. In another embodiment, a method includes configuring the rotorcraft in a selected flight condition, communicating input signals to a control system operable to position sails coupled to tips of blades of a rotor assembly, processing the input signals according to a constraint condition to generate sail positional information, and transferring the sail positional information to the sail.

  3. Tiered protocol implementation improves treatment of hypoglycaemia in a neurosciences critical care and surgical intensive care unit.

    PubMed

    Van Berkel, Megan A; MacDermott, Jennifer; Dungan, Kathleen M; Cook, Charles H; Murphy, Claire V

    2017-12-01

    Although studies demonstrate techniques to limit hypoglycaemia in critically ill patients, there are limited data supporting methods to improve management of existing hypoglycaemia. Assess the impact and sustainability of a computerised, three tiered, nurse driven protocol for hypoglycaemia treatment. Retrospective pre and post protocol study. Neurosciences and surgical intensive care units at a tertiary academic medical centre. Patients with a hypoglycaemic episode were included during a pre-protocol or post-protocol implementation period. An additional six-month cohort was evaluated to assess sustainability. Fifty-four patients were included for evaluation (35 pre- and 19 post-protocol); 122 patients were included in the sustainability cohort. Hypoglycaemia treatment significantly improved in the post-protocol cohort (20% vs. 52.6%, p=0.014); with additional improvement to 79.5% in the sustainability cohort. Time to follow-up blood glucose was decreased after treatment from 122 [Q1-Q3: 46-242] minutes pre-protocol to 25 [Q1-Q3: 9-48] minutes post protocol (p<0.0001). This reduction was maintained in the sustainability cohort [median of 29min (Q1-Q3: 20-51)]. Implementation of a nurse-driven, three-tiered protocol for treatment of hypoglyacemia significantly improved treatment rates, as well as reduced time to recheck blood glucose measurement. These benefits were sustained during a six-month period after protocol implementation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Improving Family Communications

    MedlinePlus

    ... mode Turn off more accessible mode Skip Ribbon Commands Skip to main content Turn off Animations Turn ... do the same. More Tips To Improve Communication Do Give clear, age-appropriate directions such as, "When ...

  5. Prophylactic Efficacy of Hyperimmune Bovine Colostral Antiadhesin Antibodies Against Enterotoxigenic Escherichia coli Diarrhea: A Randomized, Double-Blind, Placebo-Controlled, Phase 1 Trial.

    PubMed

    Savarino, Stephen J; McKenzie, Robin; Tribble, David R; Porter, Chad K; O'Dowd, Aisling; Cantrell, Joyce A; Sincock, Stephanie A; Poole, Steven T; DeNearing, Barbara; Woods, Colleen M; Kim, Hye; Grahek, Shannon L; Brinkley, Carl; Crabb, Joseph H; Bourgeois, A Louis

    2017-07-01

    Tip-localized adhesive proteins of bacterial fimbriae from diverse pathogens confer protection in animal models, but efficacy in humans has not been reported. Enterotoxigenic Escherichia coli (ETEC) commonly elaborate colonization factors comprising a minor tip adhesin and major stalk-forming subunit. We assessed the efficacy of antiadhesin bovine colostral IgG (bIgG) antibodies against ETEC challenge in volunteers. Adults were randomly assigned (1:1:1) to take oral hyperimmune bIgG raised against CFA/I minor pilin subunit (CfaE) tip adhesin or colonization factor I (CFA/I) fimbraie (positive control) or placebo. Two days before challenge, volunteers began a thrice-daily, 7-day course of investigational product administered in sodium bicarbonate 15 minutes after each meal. On day 3, subjects drank 1 × 109 colony-forming units of colonization factor I (CFA/I)-ETEC strain H10407 with buffer. The primary efficacy endpoint was diarrhea within 120 hours of challenge. After enrollment and randomization, 31 volunteers received product, underwent ETEC challenge, and were included in the per protocol efficacy analysis. Nine of 11 placebos developed diarrhea, 7 experiencing moderate to severe disease. Protective efficacy of 63% (P = .03) and 88% (P = .002) was observed in the antiadhesin bIgG and positive control groups, respectively. Oral administration of anti-CFA/I minor pilin subunit (CfaE) antibodies conferred significant protection against ETEC, providing the first clinical evidence that fimbrial tip adhesins function as protective antigens. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  6. FFY 2012-2015 transportation improvement program for the Dubuque, Iowa, Illinois and Wisconsin urbanized area.

    DOT National Transportation Integrated Search

    2011-08-18

    "A Transportation Improvement Program (TIP) is the Dubuque Metropolitan Area : Transportation Study (DMATS) 4- year financial implementation program listing of : transportation improvement projects eligible for Federal funding. It is DMATS : transpor...

  7. Transportation Improvement Program of the Mid-Ohio Regional Planning Commission

    DOT National Transportation Integrated Search

    1996-06-20

    The MORPC Transportation Improvement program (TIP) is a staged, multi-year schedule of regionally significant transportation improvements in the Columbus area. The Federal-aid Highway Act of 1962 and the federal Urban Mass Transportation Act of 1964 ...

  8. Clonal propagation of Phyllanthus amarus: A hepatoprotector

    PubMed Central

    Xavier, Janifer R.; Gnanam, Ramaswamy; Murugan, Muthiah P.; Pappachan, Anju

    2012-01-01

    Background: The micropropagation protocol for Phyllanthus amarus, an important medicinal herb used widely for the treatment of hepatitis in ethnomedicinal systems, was standardized with shoot tip and single node explants. Materials and Methods: The micropropagation was carried out for the hyperproducing ecotype (phyllanthin content 463.828 ppm; hypophyllanthin content: 75.469 ppm) collected from Aanaikatti, Coimbatore, and grown in mist chamber, CPMB, TNAU. For micropropagation studies, the leaves were trimmed off and the shoot tips (6 mm long) and nodal segments (single node) were used for initiation. Results: Shoot tips and single node explants gave a maximum of 6.00 and 7.00 multiple shoots per explant with Benzyl Amino Purine (BAP) (1.0mg/L mg/L). Upon subculturing, a shoot length of around 7 cm with an average of eight internodes per shoot was observed after 20 days in the elongation medium supplemented with BAP (0.2 mg/Lmg/L) and Indole Acetic Acid (IAA) (2.0 mg/L). Seven to ten adventitious roots developed when the elongated microshoots were cultured in half strength MS medium with Indole Butyric Acid (IBA) (2.0 mg/Lmg/L) and NAA (1.0 mg/L mg/L) in 15-20 days after transfer. The rooted shoots acclimatized successfully to field conditions. Conclusion: A method for successful micropropagation of the valuable medicinal plant was established which will provide a better source for continuous supply of plants for manufacturing drugs. PMID:22438668

  9. Pancreaticoportal Fistula and Disseminated Fat Necrosis After Revision of a Transjugular Intrahepatic Portosystemic Shunt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klein, Seth J., E-mail: kleins@mir.wustl.edu; Saad, Nael; Korenblat, Kevin

    A 59-year old man with alcohol related cirrhosis and portal hypertension was referred for transjugular intrahepatic portosystemic shunt (TIPS) to treat his refractory ascites. Ten years later, two sequential TIPS revisions were performed for shunt stenosis and recurrent ascites. After these revisions, he returned with increased serum pancreatic enzyme levels and disseminated superficial fat necrosis; an iatrogenic pancreaticoportal vein fistula caused by disruption of the pancreatic duct was suspected. The bare area of the TIPS was subsequently lined with a covered stent-graft, and serum enzyme levels returned to baseline. In the interval follow-up period, the patient has clinically improved.

  10. Soldering instrument safety improvements

    DOEpatents

    Kosslow, William J.; Giron, Ronald W.

    1996-01-01

    A safe soldering device includes a retractable heat shield which can be moved between a first position in which the solder tip of the device is exposed for soldering operation and a second position in which the solder tip is covered by the heat shield. Preferably, the heat shield is biased towards the second position and may be locked in the first position for ease of use. When the soldering device is equipped with a vacuum system, the heat shield may serve to guide the flow of gases and heat from the solder tip away from the work area. The heat shield is preferably made of non-heatsinking plastic.

  11. Toward a Fast-Response Active Turbine Tip Clearance Control

    NASA Technical Reports Server (NTRS)

    Melcher, Kevin J.; Kypuros, Javier A.

    2003-01-01

    This paper describes active tip clearance control research being conducted by NASA to improve turbine engine systems. The target application for this effort is commercial aircraft engines. However, technologies developed for clearance control can benefit a broad spectrum of current and future turbomachinery. The first portion of the paper addresses the research from a programmatic viewpoint. Recent studies that provide motivation for the work, identification of key technologies, and NASA's plan for addressing deficiencies in the technologies are discussed. The later portion of the paper drills down into one of the key technologies by presenting equations and results for a preliminary dynamic model of the tip clearance phenomena.

  12. Training in Temporal Information Processing Ameliorates Phonetic Identification.

    PubMed

    Szymaszek, Aneta; Dacewicz, Anna; Urban, Paulina; Szelag, Elzbieta

    2018-01-01

    Many studies revealed a link between temporal information processing (TIP) in a millisecond range and speech perception. Previous studies indicated a dysfunction in TIP accompanied by deficient phonemic hearing in children with specific language impairment (SLI). In this study we concentrate in SLI on phonetic identification, using the voice-onset-time (VOT) phenomenon in which TIP is built-in. VOT is crucial for speech perception, as stop consonants (like /t/ vs. /d/) may be distinguished by an acoustic difference in time between the onsets of the consonant (stop release burst) and the following vibration of vocal folds (voicing). In healthy subjects two categories (voiced and unvoiced) are determined using VOT task. The present study aimed at verifying whether children with SLI indicate a similar pattern of phonetic identification as their healthy peers and whether the intervention based on TIP results in improved performance on the VOT task. Children aged from 5 to 8 years ( n = 47) were assigned into two groups: normal children without any language disability (NC, n = 20), and children with SLI ( n = 27). In the latter group participants were randomly classified into two treatment subgroups, i.e., experimental temporal training (EG, n = 14) and control non-temporal training (CG, n = 13). The analyzed indicators of phonetic identification were: (1) the boundary location (α) determined as the VOT value corresponding to 50% voicing/unvoicing distinctions; (2) ranges of voiced/unvoiced categories; (3) the slope of identification curve (β) reflecting the identification correctness; (4) percent of voiced distinctions within the applied VOT spectrum. The results indicated similar α values and similar ranges of voiced/unvoiced categories between SLI and NC. However, β in SLI was significantly higher than that in NC. After the intervention, the significant improvement of β was observed only in EG. They achieved the level of performance comparable to that observed in NC. The training-related improvement in CG was non-significant. Furthermore, only in EG the β values in post-test correlated with measures of TIP as well as with phonemic hearing obtained in our previous studies. These findings provide another evidence that TIP is omnipresent in language communication and reflected not only in phonemic hearing but also in phonetic identification.

  13. Survival of mouse embryos after vitrification depending on the cooling rate of the cryoprotectant solution.

    PubMed

    Hredzák, R; Ostró, A; Zdilová, Viera; Maracek, I; Kacmárik, J

    2006-03-01

    The aim of the study was to determine the relationship between the rate of cooling of eight-cell mouse embryos to the temperature of liquid nitrogen (-196 degrees C) and their developmental capacity after thawing on the basis of their ability to leave the zona pellucida ('hatching') during in vitro culturing. Eight-cell embryos were obtained from superovulated female mice and divided into three experimental and one control group. Embryos from the experimental groups were cryopreserved by the vitrification method using ethylene glycol as cryoprotectant. The vitrification protocols used in the study differed in the rate of cooling of the cryoprotectant solution. Embryos from the first group were frozen in conventional 0.25-ml plastic straws, those from the second group in pipetting 'tips', and embryos from the third group, placed in vitrification solution, were introduced dropwise directly into liquid nitrogen. The control group of embryos was cultured in vitro without freezing in a culturing medium in an environment consisting of 95% air and 5% CO2. The developmental capacity of thawed embryos was assessed on the basis of their ability to leave the zona pellucida ('hatching') after three days of in vitro culturing. In the control group 95.1% of embryos 'hatched'. A significantly higher number of embryos that 'hatched' after thawing was observed in the group introduced dropwise directly into liquid nitrogen (60.0%) compared to the group frozen in pipetting 'tips' (37.9%). The group frozen in straws yielded significantly the lowest proportion of 'hatching' embryos (8.1%). These results showed that increasing cooling rates during vitrification of embryos improved their survival.

  14. Axial compressor blade design for desensitization of aerodynamic performance and stability to tip clearance

    NASA Astrophysics Data System (ADS)

    Erler, Engin

    Tip clearance flow is the flow through the clearance between the rotor blade tip and the shroud of a turbomachine, such as compressors and turbines. This flow is driven by the pressure difference across the blade (aerodynamic loading) in the tip region and is a major source of loss in performance and aerodynamic stability in axial compressors of modern aircraft engines. An increase in tip clearance, either temporary due to differential radial expansion between the blade and the shroud during transient operation or permanent due to engine wear or manufacturing tolerances on small blades, increases tip clearance flow and results in higher fuel consumption and higher risk of engine surge. A compressor design that can reduce the sensitivity of its performance and aerodynamic stability to tip clearance increase would have a major impact on short and long-term engine performance and operating envelope. While much research has been carried out on improving nominal compressor performance, little had been done on desensitization to tip clearance increase beyond isolated observations that certain blade designs such as forward chordwise sweep, seem to be less sensitive to tip clearance size increase. The current project aims to identify through a computational study the flow features and associated mechanisms that reduces sensitivity of axial compressor rotors to tip clearance size and propose blade design strategies that can exploit these results. The methodology starts with the design of a reference conventional axial compressor rotor followed by a parametric study with variations of this reference design through modification of the camber line and of the stacking line of blade profiles along the span. It is noted that a simple desensitization method would be to reduce the aerodynamic loading of the blade tip which would reduce the tip clearance flow and its proportional contribution to performance loss. However, with the larger part of the work on the flow done in this region, this approach would entail a nominal performance penalty. Therefore, the chosen rotor design philosophy aims to keep the spanwise loading constant to avoid trading performance for desensitization. The rotor designs that resulted from this exercise are simulated in ANSYS CFX at different tip clearance sizes. The change in their performance with respect to tip clearance size (sensitivity) is compared both on an integral level in terms of pressure ratio and adiabatic efficiency, as well as on a detailed level in terms of aerodynamic losses and blockage associated with tip clearance flow. The sensitivity of aerodynamic stability is evaluated either directly through the simulations of the rotor characteristics up to the stall point (expensive in time and resources) for a few designs or indirectly through the position of the interface between the incoming and tip clearance flow with respect to the rotor leading edge plane. The latter approach is based on a generally observed stall criteria in modern axial compressors. The rotor designs are then assessed according to their sensitivity in comparison to that of the reference rotor design to detect features that can explain the trend in sensitivity to tip clearance size. These features can then be validated and the associated flow mechanisms explained through numerical simulations and modelling. Analysis of the database from the rotor parametric study shows that the observed trend in sensitivity cannot be explained by the shifting of the aerodynamic loading along the blade chord, as initially hypothesized based on the literature review. Instead, two flow features are found to reduce sensitivity of performance and stability to tip clearance, namely an increase in incoming meridional momentum in the tip region and a reduction/elimination of double leakage flow. Double leakage flow is the flow that exits the tip clearance of one blade and proceeds into the clearance of the adjacent blade rather than convecting downstream out of the local blade passage. These flow features are isolated and validated based on the reference rotor design through changes in the inlet total pressure condition to alter incoming flow momentum and blade number count to change double leakage rate. In terms of flow mechanism, double leakage is shown to be detrimental to performance and stability, and its proportional increase with tip clearance size explains the sensitivity increase in the presence of double leakage and, conversely, the desensitization effect of reducing or eliminating double leakage. The increase in incoming meridional momentum in the tip region reduces sensitivity to tip clearance through its reduction of double leakage as well as through improved mixing with tip clearance flow, as demonstrated by an analytical model without double leakage flow. The above results imply that any blade design strategy that exploits the two desensitizing flow features would reduce the performance and stability sensitivity to tip clearance size. The increase of the incoming meridional momentum can be achieved through forward chordwise sweep of the blade. The reduction of double leakage without changing blade pitch can be obtained by decreasing the blade stagger angle in the tip region. Examples of blade designs associated with these strategies are shown through CFX simulations to be successful in reducing sensitivity to tip clearance size.

  15. Smart helicopter rotor with active blade tips

    NASA Astrophysics Data System (ADS)

    Bernhard, Andreas Paul Friedrich

    2000-10-01

    The smart active blade tip (SABT) rotor is an on-blade rotor vibration reduction system, incorporating active blade tips that can be independently pitched with respect to the main blade. The active blade tip rotor development included an experimental test program culminating in a Mach scale hover test, and a parallel development of a coupled, elastic actuator and rotor blade analysis for preliminary design studies and hover performance prediction. The experimental testing focussed on a small scale rotor on a bearingless Bell-412 hub. The fabricated Mach-scale active-tip rotor has a diameter of 1.524 m, a blade chord of 76.2 mm and incorporated a 10% span active tip. The nominal operating speed is 2000 rpm, giving a tip Mach number of 0.47. The blade tips are driven by a novel piezo-induced bending-torsion coupled actuator beam, located spanwise in the hollow mid-cell of the main rotor blade. In hover at 2000 rpm, at 2 deg collective, and for an actuation of 125 Vrms, the measured blade tip deflection at the first four rotor harmonics is between +/-1.7 and +/-2.8 deg, increasing to +/-5.3 deg at 5/rev with resonant amplification. The corresponding oscillatory amplitude of the rotor thrust coefficient is between 0.7 · 10-3 and 1.3 · 10-1 at the first four rotor harmonics, increasing to 2.1 · 10-3 at 5/rev. In general, the experimental blade tip frequency response and corresponding rotor thrust response are well captured by the analysis. The flexbeam root flap bending moment is predicted in trend, but is significantly over-estimated. The blade tips did not deflect as expected at high collective settings, because of the blade tip shaft locking up in the bearing. This is caused by the high flap bending moment on the blade tip shaft. Redesign of the blade tip shaft assembly and bearing support is identified as the primary design improvement for future research. The active blade tip rotor was also used as a testbed for the evaluation of an adaptive neural-network based control algorithm. Effective background vibration reduction of an intentional 1/rev hover imbalance was demonstrated. The control algorithm also showed the capability to generate desired multi-frequency control loads on the hub, based on artificial signal injection into the vibration measurement. The research program demonstrates the technical feasibility of the active blade tip concept for vibration reduction and warrants further investigation in terms of closed loop forward flight tests in the windtunnel and full scale design studies.

  16. Altered Mental Status: Current Evidence-based Recommendations for Prehospital Care

    PubMed Central

    Sanello, Ashley; Mulkerin, William; Sporer, Karl A.; Brown, John F.; Koenig, Kristi L.; Rudnick, Eric M.; Salvucci, Angelo A.; Gilbert, Gregory H.

    2018-01-01

    Introduction In the United States emergency medical services (EMS) protocols vary widely across jurisdictions. We sought to develop evidence-based recommendations for the prehospital evaluation and treatment of a patient with an acute change in mental status and to compare these recommendations against the current protocols used by the 33 EMS agencies in the State of California. Methods We performed a literature review of the current evidence in the prehospital treatment of a patient with altered mental status (AMS) and augmented this review with guidelines from various national and international societies to create our evidence-based recommendations. We then compared the AMS protocols of each of the 33 EMS agencies for consistency with these recommendations. The specific protocol components that we analyzed were patient assessment, point-of-care tests, supplemental oxygen, use of standardized scoring, evaluating for causes of AMS, blood glucose evaluation, toxicological treatment, and pediatric evaluation and management. Results Protocols across 33 EMS agencies in California varied widely. All protocols call for a blood glucose check, 21 (64%) suggest treating adults at <60mg/dL, and half allow for the use of dextrose 10%. All the protocols recommend naloxone for signs of opioid overdose, but only 13 (39%) give specific parameters. Half the agencies (52%) recommend considering other toxicological causes of AMS, often by using the mnemonic AEIOU TIPS. Eight (24%) recommend a 12-lead electrocardiogram; others simply suggest cardiac monitoring. Fourteen (42%) advise supplemental oxygen as needed; only seven (21%) give specific parameters. In terms of considering various etiologies of AMS, 25 (76%) give instructions to consider trauma, 20 (61%) to consider stroke, and 18 (55%) to consider seizure. Twenty-three (70%) of the agencies have separate pediatric AMS protocols; others include pediatric considerations within the adult protocol. Conclusion Protocols for patients with AMS vary widely across the State of California. The evidence-based recommendations that we present for the prehospital diagnosis and treatment of this condition may be useful for EMS medical directors tasked with creating and revising these protocols. PMID:29760852

  17. Robotically assisted ablation produces more rapid and greater signal attenuation than manual ablation.

    PubMed

    Koa-Wing, Michael; Kojodjojo, Pipin; Malcolme-Lawes, Louisa C; Salukhe, Tushar V; Linton, Nick W F; Grogan, Aaron P; Bergman, Dale; Lim, Phang Boon; Whinnett, Zachary I; McCarthy, Karen; Ho, Siew Yen; O'Neill, Mark D; Peters, Nicholas S; Davies, D Wyn; Kanagaratnam, Prapa

    2009-12-01

    Robotic remote catheter ablation potentially provides improved catheter-tip stability, which should improve the efficiency of radiofrequency energy delivery. Percentage reduction in electrogram peak-to-peak voltage has been used as a measure of effectiveness of ablation. We tested the hypothesis that improved catheter-tip stability of robotic ablation can diminish signals to a greater degree than manual ablation. In vivo NavX maps of 7 pig atria were constructed. Separate lines of ablation were performed robotically and manually, recording pre- and postablation peak-to-peak voltages at 10, 20, 30, and 60 seconds and calculating signal amplitude reduction. Catheter ablation settings were constant (25W, 50 degrees , 17 mL/min, 20-30 g catheter tip pressure). The pigs were sacrificed and ablation lesions correlated with NavX maps. Robotic ablation reduced signal amplitude to a greater degree than manual ablation (49 +/- 2.6% vs 29 +/- 4.5% signal reduction after 1 minute [P = 0.0002]). The mean energy delivered (223 +/- 184 J vs 231 +/- 190 J, P = 0.42), power (19 +/- 3.5 W vs 19 +/- 4 W, P = 0.84), and duration of ablation (15 +/- 9 seconds vs 15 +/- 9 seconds, P = 0.89) was the same for manual and robotic. The mean peak catheter-tip temperature was higher for robotic (45 +/- 5 degrees C vs 42 +/- 3 degrees C [P < 0.0001]). The incidence of >50% signal reduction was greater for robotic (37%) than manual (21%) ablation (P = 0.0001). Robotically assisted ablation appears to be more effective than manual ablation at signal amplitude reduction, therefore may be expected to produce improved clinical outcomes.

  18. Functional results in airflow improvement using a "flip-flap" alar technique: our experience.

    PubMed

    Di Stadio, Arianna; Macro, Carlo

    Pinched nasal point can be arising as congenital malformation or as results of unsuccessfully surgery. The nasal valve alteration due to this problem is not only an esthetic problem but also a functional one because can modify the nasal airflow. Several surgical techniques were proposed in literature, we proposed our. The purpose of the study is the evaluation of nose airway flow using our flip-flap technique for correction of pinched nasal tip. This is a retrospective study conducted on twelve patients. Tip cartilages were remodeled by means of autologous alar cartilage grafting. The patients underwent a rhinomanometry pre and post-surgery to evaluate the results, and they performed a self-survey to evaluate their degree of satisfaction in term of airflow sensation improvement. Rhinomanometry showed improved nasal air flow (range from 25% to 75%) in all patients. No significant differences were showed between unilateral and bilateral alar malformation (p=0.49). Patient's satisfaction reached the 87.5%. Our analysis on the combined results (rhinomanometry and surveys) showed that this technique leads to improvement of nasal flow in patients affected by pinched nasal tip in all cases. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  19. Improved extrinsic polymer optical fiber sensors for gamma-ray monitoring in radioprotection applications

    NASA Astrophysics Data System (ADS)

    de Andrés, A. I.; Esteban, Ó.; Embid, M.

    2017-08-01

    Gamma radiation detection in the range of 662 keV, the reference for environmental protection, is done through extrinsic optical fiber sensors. The fluorescence rendered by an inorganic scintillator when irradiated with such gamma rays is gathered by a modified polymer optical fiber tip. This modification increases the recorded signal when compared with plain unaltered fiber. Two fiber tip modification are then compared in terms of light gathering capability. A chemically etched fiber, in which the cladding and part of the core are removed, and a tapered fiber in which the core-cladding structure is kept. Both structures are comparable in length and final diameter, and show linear response in the tested range up to 2 Gy/h air Kerma rate. The etched fiber shows a higher slope than the tapered one, although both improve the signal gathered by a plain fiber tip. The easy fabrication and handling of the reported transducers, together with the improved signal gathering, allow to reduce the overall system budget with the use of low-cost optoelectronics in the detection stage. This offers a significant improvement for surveillance systems in radioprotection applications, in which presence of gamma radiation coming out accidental leakage or spurious sources activity is the main target.

  20. Impersonation attack on a quantum secure direct communication and authentication protocol with improvement

    NASA Astrophysics Data System (ADS)

    Amerimehr, Ali; Hadain Dehkordi, Massoud

    2018-03-01

    We analyze the security of a quantum secure direct communication and authentication protocol based on single photons. We first give an impersonation attack on the protocol. The cryptanalysis shows that there is a gap in the authentication procedure of the protocol so that an opponent can reveal the secret information by an undetectable attempt. We then propose an improvement for the protocol and show it closes the gap by applying a mutual authentication procedure. In the improved protocol single photons are transmitted once in a session, so it is easy to implement as the primary protocol. Furthermore, we use a novel technique for secret order rearrangement of photons by which not only quantum storage is eliminated also a secret key can be reused securely. So the new protocol is applicable in practical approaches like embedded system devices.

  1. Tips for Improving Seed Planting Efficiency

    Treesearch

    R. Kasten Dumroese; David L. Wenny; Susan J. Morrison

    2002-01-01

    The efficiency of a precision seeder was improved by adding a mirror so employees could monitor seed levels and by marking seeds with brightly colored talc to quickly verify the accuracy of the machine.

  2. Fall TIPS: strategies to promote adoption and use of a fall prevention toolkit.

    PubMed

    Dykes, Patricia C; Carroll, Diane L; Hurley, Ann; Gersh-Zaremski, Ronna; Kennedy, Ann; Kurowski, Jan; Tierney, Kim; Benoit, Angela; Chang, Frank; Lipsitz, Stuart; Pang, Justine; Tsurkova, Ruslana; Zuyov, Lyubov; Middleton, Blackford

    2009-11-14

    Patient falls are serious problems in hospitals. Risk factors for falls are well understood and nurses routinely assess for fall risk on all hospitalized patients. However, the link from nursing assessment of fall risk, to identification and communication of tailored interventions to prevent falls is yet to be established. The Fall TIPS (Tailoring Interventions for Patient Safety) Toolkit was developed to leverage existing practices and workflows and to employ information technology to improve fall prevention practices. The purpose of this paper is to describe the Fall TIPS Toolkit and to report on strategies used to drive adoption of the Toolkit in four acute care hospitals. Using the IHI "Framework for Spread" as a conceptual model, the research team describes the "spread" of the Fall TIPS Toolkit as means to integrate effective fall prevention practices into the workflow of interdisciplinary caregivers, patients and family members.

  3. Intrauterine device for laser light diffusion and method of using the same

    DOEpatents

    Tadir, Yona; Berns, Michael W.; Svaasand, Lars O.; Tromberg, Bruce J.

    1995-01-01

    An improved device for delivery of photoenergy from a light source, such as a laser, into a uterine cavity for photodynamic therapy is comprised of a plurality of optic fibers, which are bundled together and inserted into the uterine cavity by means of a uterine cannula. The cannula is positioned within the uterine cavity at a preferred location and then withdrawn thereby allowing the plurality of optic fibers to splay or diverge one from the other within the cavity. Different portions of the distal tip of the optic fiber is provided with a light diffusing tip, the remainder being provided with a nondiffusing tip portion. The fiber optic shape, as well as the segment which is permitted to actively diffuse light through the tip, is selected in order to provide a more uniform exposure intensity of the photo energy or at least sufficient radiation directed to each segment of the uterine walls.

  4. Intrauterine device for laser light diffusion and method of using the same

    DOEpatents

    Tadir, Y.; Berns, M.W.; Svaasand, L.O.; Tromberg, B.J.

    1995-12-26

    An improved device for delivery of photoenergy from a light source, such as a laser, into a uterine cavity for photodynamic therapy is comprised of a plurality of optic fibers, which are bundled together and inserted into the uterine cavity by means of a uterine cannula. The cannula is positioned within the uterine cavity at a preferred location and then withdrawn thereby allowing the plurality of optic fibers to splay or diverge one from the other within the cavity. Different portions of the distal tip of the optic fiber is provided with a light diffusing tip, the remainder being provided with a nondiffusing tip portion. The fiber optic shape, as well as the segment which is permitted to actively diffuse light through the tip, is selected in order to provide a more uniform exposure intensity of the photo energy or at least sufficient radiation directed to each segment of the uterine walls. 5 figs.

  5. Enhanced female attractiveness with use of cosmetics and male tipping behavior in restaurants.

    PubMed

    Guéguen, Nicolas; Jacob, Celine

    2011-01-01

    Several studies have found that cosmetics improve female facial attractiveness when judgments are made based on photographs. However, these studies were conducted only in the laboratory, while field studies are scarce in the literature. In fact, only one study has tested the effect of cosmetics on behavior. In this study the effect of cosmetics on tipping behavior and the link between behavior and judgment on the physical attractiveness of waitresses wearing or not wearing cosmetics were tested. A female waitress with or without makeup was instructed to act in her usual way with her patrons. Results showed that the makeup condition was associated with a significant increase in the tipping behavior of male customers. It was also found that the effect of makeup on tipping behavior was mediated by the perception of the physical attractiveness of the waitress, but only when considering male customers.

  6. Twelve tips for teaching in a provincially distributed medical education program.

    PubMed

    Wong, Roger Y; Chen, Luke; Dhadwal, Gurbir; Fok, Mark C; Harder, Ken; Huynh, Hanh; Lunge, Ryan; Mackenzie, Mark; Mckinney, James; Ovalle, William; Rauniyar, Pooja; Tse, Luke; Villanyi, Diane

    2012-01-01

    As distributed undergraduate and postgraduate medical education becomes more common, the challenges with the teaching and learning process also increase. To collaboratively engage front line teachers in improving teaching in a distributed medical program. We recently conducted a contest on teaching tips in a provincially distributed medical education program and received entries from faculty and resident teachers. Tips that are helpful for teaching around clinical cases at distributed teaching sites include: ask "what if" questions to maximize clinical teaching opportunities, try the 5-min short snapper, multitask to allow direct observation, create dedicated time for feedback, there are really no stupid questions, and work with heterogeneous group of learners. Tips that are helpful for multi-site classroom teaching include: promote teacher-learner connectivity, optimize the long distance working relationship, use the reality television show model to maximize retention and captivate learners, include less teaching content if possible, tell learners what you are teaching and make it relevant and turn on the technology tap to fill the knowledge gap. Overall, the above-mentioned tips offered by front line teachers can be helpful in distributed medical education.

  7. An experimental evaluation of the performance deficit of an aircraft engine starter turbine

    NASA Technical Reports Server (NTRS)

    Hass, J. E.; Roelke, R. J.; Hermann, P.

    1980-01-01

    An experimental investigation was made to determine the reasons for the low aerodynamic performance of a 13.5 centimeter tip diameter aircraft engine starter turbine. The investigation consisted of an evaluation of both the stator and the stage. An approximate ten percent improvement in turbine efficiency was obtained when the honeycomb shroud over the rotor blade tips was filled to obtain a solid shroud surface.

  8. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.

    PubMed

    Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R

    2017-07-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  9. Simulations of Fuel Assembly and Fast-Electron Transport in Integrated Fast-Ignition Experiments on OMEGA

    NASA Astrophysics Data System (ADS)

    Solodov, A. A.; Theobald, W.; Anderson, K. S.; Shvydky, A.; Epstein, R.; Betti, R.; Myatt, J. F.; Stoeckl, C.; Jarrott, L. C.; McGuffey, C.; Qiao, B.; Beg, F. N.; Wei, M. S.; Stephens, R. B.

    2013-10-01

    Integrated fast-ignition experiments on OMEGA benefit from improved performance of the OMEGA EP laser, including higher contrast, higher energy, and a smaller focus. Recent 8-keV, Cu-Kα flash radiography of cone-in-shell implosions and cone-tip breakout measurements showed good agreement with the 2-D radiation-hydrodynamic simulations using the code DRACO. DRACO simulations show that the fuel assembly can be further improved by optimizing the compression laser pulse, evacuating air from the shell, and by adjusting the material of the cone tip. This is found to delay the cone-tip breakout by ~220 ps and increase the core areal density from ~80 mg/cm2 in the current experiments to ~500 mg/cm2 at the time of the OMEGA EP beam arrival before the cone-tip breakout. Simulations using the code LSP of fast-electron transport in the recent integrated OMEGA experiments with Cu-doped shells will be presented. Cu-doping is added to probe the transport of fast electrons via their induced Cu K-shell fluorescent emission. This material is based upon work supported by the Department of Energy National Nuclear Security Administration DE-NA0001944 and the Office of Science under DE-FC02-04ER54789.

  10. Distributed collaborative probabilistic design for turbine blade-tip radial running clearance using support vector machine of regression

    NASA Astrophysics Data System (ADS)

    Fei, Cheng-Wei; Bai, Guang-Chen

    2014-12-01

    To improve the computational precision and efficiency of probabilistic design for mechanical dynamic assembly like the blade-tip radial running clearance (BTRRC) of gas turbine, a distribution collaborative probabilistic design method-based support vector machine of regression (SR)(called as DCSRM) is proposed by integrating distribution collaborative response surface method and support vector machine regression model. The mathematical model of DCSRM is established and the probabilistic design idea of DCSRM is introduced. The dynamic assembly probabilistic design of aeroengine high-pressure turbine (HPT) BTRRC is accomplished to verify the proposed DCSRM. The analysis results reveal that the optimal static blade-tip clearance of HPT is gained for designing BTRRC, and improving the performance and reliability of aeroengine. The comparison of methods shows that the DCSRM has high computational accuracy and high computational efficiency in BTRRC probabilistic analysis. The present research offers an effective way for the reliability design of mechanical dynamic assembly and enriches mechanical reliability theory and method.

  11. Exhaust emission reduction for intermittent combustion aircraft engines

    NASA Technical Reports Server (NTRS)

    Moffett, R. N.

    1979-01-01

    Three concepts for optimizing the performance, increasing the fuel economy, and reducing exhaust emission of the piston aircraft engine were investigated. High energy-multiple spark discharge and spark plug tip penetration, ultrasonic fuel vaporization, and variable valve timing were evaluated individually. Ultrasonic fuel vaporization did not demonstrate sufficient improvement in distribution to offset the performance loss caused by the additional manifold restriction. High energy ignition and revised spark plug tip location provided no change in performance or emissions. Variable valve timing provided some performance benefit; however, even greater performance improvement was obtained through induction system tuning which could be accomplished with far less complexity.

  12. PhenoTips: patient phenotyping software for clinical and research use.

    PubMed

    Girdea, Marta; Dumitriu, Sergiu; Fiume, Marc; Bowdin, Sarah; Boycott, Kym M; Chénier, Sébastien; Chitayat, David; Faghfoury, Hanna; Meyn, M Stephen; Ray, Peter N; So, Joyce; Stavropoulos, Dimitri J; Brudno, Michael

    2013-08-01

    We have developed PhenoTips: open source software for collecting and analyzing phenotypic information for patients with genetic disorders. Our software combines an easy-to-use interface, compatible with any device that runs a Web browser, with a standardized database back end. The PhenoTips' user interface closely mirrors clinician workflows so as to facilitate the recording of observations made during the patient encounter. Collected data include demographics, medical history, family history, physical and laboratory measurements, physical findings, and additional notes. Phenotypic information is represented using the Human Phenotype Ontology; however, the complexity of the ontology is hidden behind a user interface, which combines simple selection of common phenotypes with error-tolerant, predictive search of the entire ontology. PhenoTips supports accurate diagnosis by analyzing the entered data, then suggesting additional clinical investigations and providing Online Mendelian Inheritance in Man (OMIM) links to likely disorders. By collecting, classifying, and analyzing phenotypic information during the patient encounter, PhenoTips allows for streamlining of clinic workflow, efficient data entry, improved diagnosis, standardization of collected patient phenotypes, and sharing of anonymized patient phenotype data for the study of rare disorders. Our source code and a demo version of PhenoTips are available at http://phenotips.org. © 2013 WILEY PERIODICALS, INC.

  13. Fusion of electromagnetic trackers to improve needle deflection estimation: simulation study.

    PubMed

    Sadjadi, Hossein; Hashtrudi-Zaad, Keyvan; Fichtinger, Gabor

    2013-10-01

    We present a needle deflection estimation method to anticipate needle bending during insertion into deformable tissue. Using limited additional sensory information, our approach reduces the estimation error caused by uncertainties inherent in the conventional needle deflection estimation methods. We use Kalman filters to combine a kinematic needle deflection model with the position measurements of the base and the tip of the needle taken by electromagnetic (EM) trackers. One EM tracker is installed on the needle base and estimates the needle tip position indirectly using the kinematic needle deflection model. Another EM tracker is installed on the needle tip and estimates the needle tip position through direct, but noisy measurements. Kalman filters are then employed to fuse these two estimates in real time and provide a reliable estimate of the needle tip position, with reduced variance in the estimation error. We implemented this method to compensate for needle deflection during simulated needle insertions and performed sensitivity analysis for various conditions. At an insertion depth of 150 mm, we observed needle tip estimation error reductions in the range of 28% (from 1.8 to 1.3 mm) to 74% (from 4.8 to 1.2 mm), which demonstrates the effectiveness of our method, offering a clinically practical solution.

  14. Ultrathin MoS2 and WS2 layers on silver nano-tips as electron emitters

    NASA Astrophysics Data System (ADS)

    Loh, Tamie A. J.; Tanemura, Masaki; Chua, Daniel H. C.

    2016-09-01

    2-dimensional (2D) inorganic analogues of graphene such as MoS2 and WS2 present interesting opportunities for field emission technology due to their high aspect ratio and good electrical conductivity. However, research on 2D MoS2 and WS2 as potential field emitters remains largely undeveloped compared to graphene. Herein, we present an approach to directly fabricate ultrathin MoS2 and WS2 onto Ag nano-tips using pulsed laser deposition at low temperatures of 450-500 °C. In addition to providing a layer of chemical and mechanical protection for the Ag nano-tips, the growth of ultrathin MoS2 and WS2 layers on Ag led to enhanced emission properties over that of pristine nano-tips due to a reduction of the effective barrier height arising from charge injection from Ag to the overlying MoS2 or WS2. For WS2 on Ag nano-tips, the phasic mixture was also an important factor influencing the field emission performance. The presence of 1T-WS2 at the metal-WS2 interface in a hybrid film of 2H/1T-WS2 leads to improvement in the field emission capabilities as compared to pure 2H-WS2 on Ag nano-tips.

  15. Protocol for laparoscopic cholecystectomy: Is it rocket science?

    PubMed

    Hori, Tomohide; Oike, Fumitaka; Furuyama, Hiroaki; Machimoto, Takafumi; Kadokawa, Yoshio; Hata, Toshiyuki; Kato, Shigeru; Yasukawa, Daiki; Aisu, Yuki; Sasaki, Maho; Kimura, Yusuke; Takamatsu, Yuichiro; Naito, Masato; Nakauchi, Masaya; Tanaka, Takahiro; Gunji, Daigo; Nakamura, Kiyokuni; Sato, Kiyoko; Mizuno, Masahiro; Iida, Taku; Yagi, Shintaro; Uemoto, Shinji; Yoshimura, Tsunehiro

    2016-12-21

    Laparoscopic cholecystectomy (LC) does not require advanced techniques, and its performance has therefore rapidly spread worldwide. However, the rate of biliary injuries has not decreased. The concept of the critical view of safety (CVS) was first documented two decades ago. Unexpected injuries are principally due to misidentification of human factors. The surgeon's assumption is a major cause of misidentification, and a high level of experience alone is not sufficient for successful LC. We herein describe tips and pitfalls of LC in detail and discuss various technical considerations. Finally, based on a review of important papers and our own experience, we summarize the following mandatory protocol for safe LC: (1) consideration that a high level of experience alone is not enough; (2) recognition of the plateau involving the common hepatic duct and hepatic hilum; (3) blunt dissection until CVS exposure; (4) Calot's triangle clearance in the overhead view; (5) Calot's triangle clearance in the view from underneath; (6) dissection of the posterior right side of Calot's triangle; (7) removal of the gallbladder body; and (8) positive CVS exposure. We believe that adherence to this protocol will ensure successful and beneficial LC worldwide, even in patients with inflammatory changes and rare anatomies.

  16. A Reduced Model for Prediction of Thermal and Rotational Effects on Turbine Tip Clearance

    NASA Technical Reports Server (NTRS)

    Kypuros, Javier A.; Melcher, Kevin J.

    2003-01-01

    This paper describes a dynamic model that was developed to predict changes in turbine tip clearance the radial distance between the end of a turbine blade and the abradable tip seal. The clearance is estimated by using a first principles approach to model the thermal and mechanical effects of engine operating conditions on the turbine sub-components. These effects are summed to determine the resulting clearance. The model is demonstrated via a ground idle to maximum power transient and a lapse-rate takeoff transient. Results show the model demonstrates the expected pinch point behavior. The paper concludes by identifying knowledge gaps and suggesting additional research to improve the model.

  17. Cryptanalysis and Improvements for the Quantum Private Comparison Protocol Using EPR Pairs

    NASA Astrophysics Data System (ADS)

    Wang, Cong; Xu, Gang; Yang, Yi-Xian

    2013-07-01

    In this paper, we carry out an in-depth analysis of the quantum private comparison (QPC) protocol with the semi-honest third party (TP). The security of QPC protocol using the EPR pairs is re-examined. Unfortunately, we find that TP can use the fake EPR pairs to steal all the secret information. Furthermore, we give two simple and feasible solutions to improve the original QPC protocol. It is shown that the improved protocol is secure, which can resist various kinds of attacks from both the outside eavesdroppers and the inside participants, even the semi-honest TP.

  18. A Secure and Efficient Handover Authentication Protocol for Wireless Networks

    PubMed Central

    Wang, Weijia; Hu, Lei

    2014-01-01

    Handover authentication protocol is a promising access control technology in the fields of WLANs and mobile wireless sensor networks. In this paper, we firstly review an efficient handover authentication protocol, named PairHand, and its existing security attacks and improvements. Then, we present an improved key recovery attack by using the linearly combining method and reanalyze its feasibility on the improved PairHand protocol. Finally, we present a new handover authentication protocol, which not only achieves the same desirable efficiency features of PairHand, but enjoys the provable security in the random oracle model. PMID:24971471

  19. Surgeon-authored Virtual Laparoscopic Adrenalectomy Module is Judged Effective and Preferred over Traditional Teaching Tools

    PubMed Central

    Kurenov, Sergei; Cendan, Juan; Dindar, Sahel; Attwood, Kristopher; Hassett, James; Nawotniak, Ruth; Cherr, Gregory; Cance, William G.; Peters, Jörg

    2018-01-01

    Objective The study assesses user acceptance and effectiveness of a surgeon-authored virtual reality training module authored by surgeons using the Toolkit for Illustration Procedures in Surgery (TIPS). Methods Laparoscopic adrenalectomy was selected to test the TIPS framework on an unusual and complex procedure. No commercial simulation module exists to teach this procedure. A specialist surgeon authored the module, including force-feedback interactive simulation and designed a quiz to test knowledge of the key procedural steps. Five practicing surgeons with 15 to 24 years of experience peer-reviewed and tested the module. Fourteen residents and nine fellows trained with the module and answered the quiz, pre-use and post-use. Participants received an overview during Surgical Grand Rounds session and a 20-minute one- on-one tutorial followed by a 30 minute of instruction in addition to a force-feedback interactive simulation session. Additionally, in answering questionnaires, the trainees reflected on their learning experience and their experience with the TIPS framework. Results Correct quiz response rates on procedural steps improved significantly post-use over pre-use. In the questionnaire, 96% of the respondents stated that the TIPS module prepares them well or very well for the adrenalectomy, and 87% indicated that the module successfully teaches the steps of the procedure. All subjects indicated that they preferred the module compare to training using purely physical props, one-on-one teaching, medical atlases, and video recordings. Conclusions Improved quiz scores and endorsement by the participants of the TIPS adrenalectomy module establish the viability of surgeons authoring virtual reality training. PMID:27758896

  20. Thermogravimetric Analysis of Single-Wall Carbon Nanotubes

    NASA Technical Reports Server (NTRS)

    Arepalli, Sivram; Nikolaev, Pavel; Gorelik, Olga

    2010-01-01

    An improved protocol for thermogravimetric analysis (TGA) of samples of single-wall carbon nanotube (SWCNT) material has been developed to increase the degree of consistency among results so that meaningful comparisons can be made among different samples. This improved TGA protocol is suitable for incorporation into the protocol for characterization of carbon nanotube material. In most cases, TGA of carbon nanotube materials is performed in gas mixtures that contain oxygen at various concentrations. The improved protocol is summarized.

  1. [Acceptance and commitment therapy (ACT) and improving chess performance in promising young chess-players].

    PubMed

    Ruiz, Francisco J; Luciano, Carmen

    2009-08-01

    Acceptance and Commitment Therapy (ACT) is shown to be effective in relatively distant fields from the so-called psychological disorders. One of these areas is sport performance improvement. The aim of the current study is to expand the application of brief ACT protocols to improve chess-players' performance. In a previous study, a brief protocol was applied to international-level adult chess-players that was effective. The current study aims to apply an equivalent brief ACT protocol, but in this case, applied in a group format to promising young chess-players. In addition, this brief protocol is compared to a non-intervention control condition. Results show that the ACT brief protocol improved the performance in 5 out of 7 participants, and that none of the chess-players in the control condition reached the established change criterion. The differences between the conditions in chess performance were statistically significant. The results are discussed, emphasizing the replicated impact of a brief ACT protocol on the improvement of chess-players' performance.

  2. An investigation of rotor tip leakage flows in the rear-block of a multistage compressor

    NASA Astrophysics Data System (ADS)

    Brossman, John Richard

    An effective method to improve gas turbine propulsive efficiency is to increase the bypass ratio. With fan diameter reaching a practical limit, increases in bypass ratio can be obtained from reduced core engine size. Decreasing the engine core, results in small, high pressure compressor blading, and large relative tip clearances. At general rule of 1% reduction in compressor efficiency with a 1% increase in tip clearance, a 0.66% change in SFC indicates the entire engine is sensitive to high pressure compressor tip leakage flows. Therefore, further investigations and understanding of the rotor tip leakage flows can help to improve gas turbine engine efficiency. The objectives of this research were to investigate tip leakage flows through computational modeling, examine the baseline experimental steady-stage performance, and acquire unsteady static pressure, over-the rotor to observe the tip leakage flow structure. While tip leakage flows have been investigated in the past, there have been no facilities capable of matching engine representative Reynolds number and Mach number while maintaining blade row interactions, presenting a unique and original flow field to investigate at the Purdue 3-stage axial compressor facility. To aid the design of experimental hardware and determine the influence of clearance geometry on compressor performance, a computational model of the Purdue 3-stage compressor was investigated using a steady RANS CFD analysis. A cropped rotor and casing recess design was investigated to increase the rotor tip clearance. While there were small performance differences between the geometries, the tip leakage flow field was found independent of the design therefore designing future experimental hardware around a casing recess is valid. The largest clearance with flow margin past the design point was 4% tip clearance based on the computational model. The Purdue 3-stage axial compressor facility was rebuilt and setup for high quality, detailed flow measurements during this investigation. A detailed investigation and sensitivity analysis of the inlet flow field found the influence by the inlet total temperature profile was important to performance calculations. This finding was significant and original as previous investigations have been conducted on low-speed machines where there is minimal temperature rise. The steady state performance of the baseline 1.5% tip clearance case was outlined at design speed and three off-design speeds. The leakage flow from the rear seal, the inlet flow field and a thermal boundary condition over the casing was recorded at each operating point. Stage 1 was found to be the limiting stage independent of speed. Few datasets exist on multistage compressor performance with full boundary condition definitions, especially with off-design operating points presenting this as a unique dataset for CFD comparison. The detailed unsteady pressure measurements were conducted over Rotor 1 at design and a near-stall operating condition to characterize the leakage trajectory and position. The leakage flow initial point closer to the leading edge and trajectory angle increased at the higher loading condition. The over-the-rotor static pressure field on Rotor 1 indicated similar trends between the computational model and the leakage trajectory.

  3. Gene delivery by direct injection (microinjection) using a controlled-flow system.

    PubMed

    Dean, David A

    2006-12-01

    INTRODUCTIONThis protocol describes a method for constant-flow microinjection using the Pneumatic PicoPump (World Precision Instruments). This type of system is very simple and can be assembled on a relatively low budget. In this method, a constant flow of sample is delivered from the tip of the pipette, and the amount of sample injected into the cell is determined by how long the pipette remains in the cell. A typical system is composed of a pressure regulator that can be adjusted for two pressures (back pressure and injection pressure), a capillary holder, and a coarse and fine micromanipulator.

  4. Antibonding ground state of adatom molecules in bulk Dirac semimetals

    NASA Astrophysics Data System (ADS)

    Marques, Y.; Obispo, A. E.; Ricco, L. S.; de Souza, M.; Shelykh, I. A.; Seridonio, A. C.

    2017-07-01

    The ground state of the diatomic molecules in nature is inevitably bonding, and its first excited state is antibonding. We demonstrate theoretically that, for a pair of distant adatoms placed buried in three-dimensional-Dirac semimetals, this natural order of the states can be reversed and an antibonding ground state occurs at the lowest energy of the so-called bound states in the continuum. We propose an experimental protocol with the use of a scanning tunneling microscope tip to visualize the topographic map of the local density of states on the surface of the system to reveal the emerging physics.

  5. Intravascular US-Guided Portal Vein Access: Improved Procedural Metrics during TIPS Creation.

    PubMed

    Gipson, Matthew G; Smith, Mitchell T; Durham, Janette D; Brown, Anthony; Johnson, Thor; Ray, Charles E; Gupta, Rajan K; Kondo, Kimi L; Rochon, Paul J; Ryu, Robert K

    2016-08-01

    To evaluate transjugular intrahepatic portosystemic shunt (TIPS) outcomes and procedure metrics with the use of three different image guidance techniques for portal vein (PV) access during TIPS creation. A retrospective review of consecutive patients who underwent TIPS procedures for a range of indications during a 28-month study period identified a population of 68 patients. This was stratified by PV access techniques: fluoroscopic guidance with or without portography (n = 26), PV marker wire guidance (n = 18), or intravascular ultrasound (US) guidance (n = 24). Procedural outcomes and procedural metrics, including radiation exposure, contrast agent volume used, procedure duration, and PV access time, were analyzed. No differences in demographic or procedural characteristics were found among the three groups. Technical success, technical success of the primary planned approach, hemodynamic success, portosystemic gradient, and procedure-related complications were not significantly different among groups. Fluoroscopy time (P = .003), air kerma (P = .01), contrast agent volume (P = .003), and total procedural time (P = .02) were reduced with intravascular US guidance compared with fluoroscopic guidance. Fluoroscopy time (P = .01) and contrast agent volume (P = .02) were reduced with intravascular US guidance compared with marker wire guidance. Intravascular US guidance of PV access during TIPS creation not only facilitates successful TIPS creation in patients with challenging anatomy, as suggested by previous investigations, but also reduces important procedure metrics including radiation exposure, contrast agent volume, and overall procedure duration compared with fluoroscopically guided TIPS creation. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  6. Osteoconduction of impacted porous titanium particles with a calcium-phosphate coating is comparable to osteoconduction of impacted allograft bone particles: in vivo study in a nonloaded goat model.

    PubMed

    Walschot, Lucas H B; Aquarius, René; Schreurs, Barend W; Verdonschot, Nico; Buma, Pieter

    2012-08-01

    Impaction grafting restores bone defects in hip arthroplasty. Defects are reconstructed with bone particles (BoP) as substitute materials with adequate mechanical and biological properties are not yet available. Ceramic particles (CeP) have mechanical drawbacks as opposed to porous titanium particles (TiP). In this in vivo study, bone ingrowth and bone volume in coated and noncoated TiP were compared to porous biphasic calcium-phospate CeP and allograft BoP. Coatings consisted of silicated calcium-phosphate and carbonated apatite. Materials were implanted in goats and impacted in cylindrical defects (diameter 8 mm) in the cancellous bone of the femur. On the basis of fluorochrome labeling and histology, bone ingrowth distance was measured at 4, 8, and 12 weeks. Cross-sectional bone area was measured at 12 weeks. TiP created a coherent matrix of entangled particles. CeP pulverized and were noncoherent. Bone ingrowth in TiP improved significantly by the coatings to levels comparable to BoP and CeP. Cross-sectional bone area was smaller in CeP and TiP compared to BoP. The osteoconductive properties of impacted TiP with a calcium-phosphate coating are comparable to impacted allograft bone and impacted biphasic ceramics. A more realistic loaded in vivo study should prove that coated TiP is an attractive alternative to allograft bone. Copyright © 2012 Wiley Periodicals, Inc.

  7. Strong, Ductile Rotor For Cryogenic Flowmeters

    NASA Technical Reports Server (NTRS)

    Royals, W. T.

    1993-01-01

    Improved magnetic flowmeter rotor resists cracking at cryogenic temperatures, yet provides adequate signal to magnetic pickup outside flowmeter housing. Consists mostly of stainless-steel alloy 347, which is ductile and strong at low temperatures. Small bead of stainless-steel alloy 410 welded in groove around circumference of round bar of stainless-steel alloy 347; then rotor machined from bar. Tips of rotor blades contain small amounts of magnetic alloy, and passage of tips detected.

  8. The Effect of Unsteady Wakes on Turbine Tip Gap Leakage

    DTIC Science & Technology

    2013-05-10

    low speed wind tunnel. The turbine blade shape for the experiment was the GE E 3 high pressure turbine stage 1 blade (Halila et al. 1982). The E 3...DATES COVERED (From - To) 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER The Effect of Unsteady Wakes on Turbine Tip Gap Leakage...Gas turbines are found in military and civilian aircraft, ships, and power plants. Because of this widespread use, relatively small improvements

  9. Moving an Evidence-Based Policy Agenda Forward: Leadership Tips From the Field.

    PubMed

    Garrett, Teresa

    2018-05-01

    Advancing evidence-based policy change is a leadership challenge that nurses should embrace. Key tips to ensure that evidence-based policy changes are successful at the individual, community, and population levels are offered to help nurses through the change process. The public trust in the nursing profession is a leverage point that should be used to advance the use of evidence, expedite change, and improve health for students and across communities.

  10. Anatomical and functional characteristics of carotid sinus stimulation in humans

    NASA Technical Reports Server (NTRS)

    Querry, R. G.; Smith, S. A.; Stromstad, M.; Ide, K.; Secher, N. H.; Raven, P. B.

    2001-01-01

    Transmission characteristics of pneumatic pressure to the carotid sinus were evaluated in 19 subjects at rest and during exercise. Either a percutaneous fluid-filled (n = 12) or balloon-tipped catheter (n = 7) was placed at the carotid bifurcation to record internal transmission of external neck pressure/neck suction (NP/NS). Sustained, 5-s pulses, and rapid ramping pulse protocols (+40 to -80 Torr) were recorded. Transmission of pressure stimuli was less with the fluid-filled catheter compared with that of the balloon-tipped catheter (65% vs. 82% negative pressure, 83% vs. 89% positive pressure; P < 0.05). Anatomical location of the carotid sinus averaged 3.2 cm (left) and 3.6 cm (right) from the gonion of the mandible with a range of 0-7.5 cm. Transmission was not altered by exercise or Valsalva maneuver, but did vary depending on the position of the carotid sinus locus beneath the sealed chamber. These data indicate that transmission of external NP/NS was higher than previously recorded in humans, and anatomical variation of carotid sinus location and equipment design can affect transmission results.

  11. An improved ATAC-seq protocol reduces background and enables interrogation of frozen tissues.

    PubMed

    Corces, M Ryan; Trevino, Alexandro E; Hamilton, Emily G; Greenside, Peyton G; Sinnott-Armstrong, Nicholas A; Vesuna, Sam; Satpathy, Ansuman T; Rubin, Adam J; Montine, Kathleen S; Wu, Beijing; Kathiria, Arwa; Cho, Seung Woo; Mumbach, Maxwell R; Carter, Ava C; Kasowski, Maya; Orloff, Lisa A; Risca, Viviana I; Kundaje, Anshul; Khavari, Paul A; Montine, Thomas J; Greenleaf, William J; Chang, Howard Y

    2017-10-01

    We present Omni-ATAC, an improved ATAC-seq protocol for chromatin accessibility profiling that works across multiple applications with substantial improvement of signal-to-background ratio and information content. The Omni-ATAC protocol generates chromatin accessibility profiles from archival frozen tissue samples and 50-μm sections, revealing the activities of disease-associated DNA elements in distinct human brain structures. The Omni-ATAC protocol enables the interrogation of personal regulomes in tissue context and translational studies.

  12. Improving the multiparty quantum secret sharing over two collective-noise channels against insider attack

    NASA Astrophysics Data System (ADS)

    Sun, Ying; Wen, Qiao-yan; Zhu, Fu-chen

    2010-01-01

    The security of the multiparty quantum secret sharing protocol presented by Zhang [Z.J. Zhang, Physica A, 361 (2006) 233] is analyzed. It is shown that this protocol is vulnerable to the insider attack since eavesdropping detection is performed only when all states arrive at the last agent. We propose an attack strategy and give an improved version of the original protocol. The improved protocol is robust and has the same traits with the original one.

  13. 40 CFR 93.101 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Implementation Plans of Transportation Plans, Programs, and Projects Developed, Funded or Approved Under Title 23.... Transportation improvement program (TIP) means a transportation improvement program developed by a metropolitan... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) DETERMINING...

  14. CF6 jet engine performance improvement: New fan

    NASA Technical Reports Server (NTRS)

    Fasching, W. A.

    1980-01-01

    As part of the NASA sponsored engine component improvement program, and fan package was developed to reduce fuel consumption in current CF6 turbofan aircraft engine. The new fan package consist of an improved fan blade, reduced fan tip clearance due to a fan case stiffener, and a smooth fan casing tip shroud. CF6 engine performance and acoustic tests demonstrated the predicted 1.8% improvement in cruise sfc without an increase in engine noise. Power management thrust/fan speed characteristics were defined. Mechanical and structural integrity was demonstrated in model fan rotor photoelastic stress tests, full-size fan blade bench fatigue tests, and CF6 engine bird ingestion, crosswind, and cyclic endurance tests. The fan was certified in the CF6-500c2/E2 engines and is in commerical service on the Boeing 747-200, Douglas DC-10-30, and Atrbus industrie A300B aircraft.

  15. A comparative study of routing protocols of heterogeneous wireless sensor networks.

    PubMed

    Han, Guangjie; Jiang, Xu; Qian, Aihua; Rodrigues, Joel J P C; Cheng, Long

    2014-01-01

    Recently, heterogeneous wireless sensor network (HWSN) routing protocols have drawn more and more attention. Various HWSN routing protocols have been proposed to improve the performance of HWSNs. Among these protocols, hierarchical HWSN routing protocols can improve the performance of the network significantly. In this paper, we will evaluate three hierarchical HWSN protocols proposed recently--EDFCM, MCR, and EEPCA--together with two previous classical routing protocols--LEACH and SEP. We mainly focus on the round of the first node dies (also called the stable period) and the number of packets sent to sink, which is an important aspect to evaluate the monitoring ability of a protocol. We conduct a lot of experiments and simulations on Matlab to analyze the performance of the five routing protocols.

  16. Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography.

    PubMed

    Owen, Joshua M; Gaba, Ron Charles

    2016-01-01

    The objective of this study was to evaluate the concordance between clinical symptoms, Doppler ultrasound (US), and shunt venography for the detection of stent-graft transjugular intrahepatic portosystemic shunt (TIPS) dysfunction. Forty-one patients (M:F 30:11, median age 55 years) who underwent contemporaneous clinical exam, Doppler US, and TIPS venography between 2003 and 2014 were retrospectively studied. Clinical symptoms (recurrent ascites or variceal bleeding) were dichotomously classified as present/absent, and US and TIPS venograms were categorized in a binary fashion as normal/abnormal. US abnormalities included high/low (>190 or <90 cm/s) TIPS velocity, significant velocity rise/fall (>50 cm/s), absent flow, and return of antegrade intra-hepatic portal flow. Venographic abnormalities included shunt stenosis/occlusion and/or pressure gradient elevation. Clinical and imaging concordance rates were calculated. Fifty-two corresponding US examinations and venograms were assessed. The median time between studies was 3 days. Forty of 52 (77%) patients were symptomatic, 33/52 (64%) US examinations were abnormal, and 20/52 (38%) TIPS venograms were abnormal. Concordance between clinical symptoms and TIPS venography was 48% (25/52), while the agreement between US and shunt venography was 65% (34/52). Clinical symptoms and the US concurred in 60% (31/52) of the patients. The sensitivity of clinical symptoms and US for the detection of venographically abnormal shunts was 80% (16/20) and 85% (17/20), respectively. Both clinical symptoms and the US had low specificity (25%, 8/32 and 50%, 16/32) for venographically abnormal shunts. Clinical findings and the US had low concordance rates with TIPS venography, with acceptable sensitivity but poor specificity. These findings suggest the need for improved noninvasive imaging methods for stent-graft TIPS surveillance.

  17. Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography

    PubMed Central

    Owen, Joshua M; Gaba, Ron Charles

    2016-01-01

    Objectives: The objective of this study was to evaluate the concordance between clinical symptoms, Doppler ultrasound (US), and shunt venography for the detection of stent-graft transjugular intrahepatic portosystemic shunt (TIPS) dysfunction. Materials and Methods: Forty-one patients (M:F 30:11, median age 55 years) who underwent contemporaneous clinical exam, Doppler US, and TIPS venography between 2003 and 2014 were retrospectively studied. Clinical symptoms (recurrent ascites or variceal bleeding) were dichotomously classified as present/absent, and US and TIPS venograms were categorized in a binary fashion as normal/abnormal. US abnormalities included high/low (>190 or <90 cm/s) TIPS velocity, significant velocity rise/fall (>50 cm/s), absent flow, and return of antegrade intra-hepatic portal flow. Venographic abnormalities included shunt stenosis/occlusion and/or pressure gradient elevation. Clinical and imaging concordance rates were calculated. Results: Fifty-two corresponding US examinations and venograms were assessed. The median time between studies was 3 days. Forty of 52 (77%) patients were symptomatic, 33/52 (64%) US examinations were abnormal, and 20/52 (38%) TIPS venograms were abnormal. Concordance between clinical symptoms and TIPS venography was 48% (25/52), while the agreement between US and shunt venography was 65% (34/52). Clinical symptoms and the US concurred in 60% (31/52) of the patients. The sensitivity of clinical symptoms and US for the detection of venographically abnormal shunts was 80% (16/20) and 85% (17/20), respectively. Both clinical symptoms and the US had low specificity (25%, 8/32 and 50%, 16/32) for venographically abnormal shunts. Conclusion: Clinical findings and the US had low concordance rates with TIPS venography, with acceptable sensitivity but poor specificity. These findings suggest the need for improved noninvasive imaging methods for stent-graft TIPS surveillance. PMID:27563495

  18. Transjugular Intrahepatic Portosystemic Shunt Flow Reduction with Adjustable Polytetrafluoroethylene-Covered Balloon-Expandable Stents Using the “Sheath Control” Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blue, Robert C., E-mail: Robert.c.blue@gmail.com; Lo, Grace C.; Kim, Edward

    PurposeA complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a “sheath control technique” utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.MethodsTIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm × 59 mm iCast stent was deployed with 2 cm exposed from the sheath’s distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloonmore » retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded.ResultsTen patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients’ MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively).ConclusionTIPS reduction using Atrium iCast PTFE balloon-expandable stents using the “sheath control technique” is safe and effective, and minimizes the risk of stent migration.« less

  19. Performance of post-processing algorithms for rainfall intensity using measurements from tipping-bucket rain gauges

    NASA Astrophysics Data System (ADS)

    Stagnaro, Mattia; Colli, Matteo; Lanza, Luca Giovanni; Chan, Pak Wai

    2016-11-01

    Eight rainfall events recorded from May to September 2013 at Hong Kong International Airport (HKIA) have been selected to investigate the performance of post-processing algorithms used to calculate the rainfall intensity (RI) from tipping-bucket rain gauges (TBRGs). We assumed a drop-counter catching-type gauge as a working reference and compared rainfall intensity measurements with two calibrated TBRGs operated at a time resolution of 1 min. The two TBRGs differ in their internal mechanics, one being a traditional single-layer dual-bucket assembly, while the other has two layers of buckets. The drop-counter gauge operates at a time resolution of 10 s, while the time of tipping is recorded for the two TBRGs. The post-processing algorithms employed for the two TBRGs are based on the assumption that the tip volume is uniformly distributed over the inter-tip period. A series of data of an ideal TBRG is reconstructed using the virtual time of tipping derived from the drop-counter data. From the comparison between the ideal gauge and the measurements from the two real TBRGs, the performances of different post-processing and correction algorithms are statistically evaluated over the set of recorded rain events. The improvement obtained by adopting the inter-tip time algorithm in the calculation of the RI is confirmed. However, by comparing the performance of the real and ideal TBRGs, the beneficial effect of the inter-tip algorithm is shown to be relevant for the mid-low range (6-50 mmh-1) of rainfall intensity values (where the sampling errors prevail), while its role vanishes with increasing RI in the range where the mechanical errors prevail.

  20. Improvements of Quantum Private Comparison Protocol Based on Cluster States

    NASA Astrophysics Data System (ADS)

    Zhou, Ming-Kuai

    2018-01-01

    Quantum private comparison aims to determine whether the secrets from two different users are equal or not by utilizing the laws of quantum mechanics. Recently, Sun and Long put forward a quantum private comparison (QPC) protocol by using four-particle cluster states (Int. J. Theor. Phys. 52, 212-218, 2013). In this paper, we investigate this protocol in depth, and suggest the corresponding improvements. Compared with the original protocol, the improved protocol has the following advantages: 1) it can release the requirements of authenticated classical channels and unitary operations; 2) it can prevent the malicious attack from the genuine semi-honest TP; 3) it can enhance the qubit efficiency.

  1. Isolation, Characterization, and Purification of Macrophages from Tissues Affected by Obesity-related Inflammation.

    PubMed

    Allen, Joselyn N; Dey, Adwitia; Nissly, Ruth; Fraser, James; Yu, Shan; Balandaram, Gayathri; Peters, Jeffrey M; Hankey-Giblin, Pamela A

    2017-04-03

    Obesity promotes a chronic inflammatory state that is largely mediated by tissue-resident macrophages as well as monocyte-derived macrophages. Diet-induced obesity (DIO) is a valuable model in studying the role of macrophage heterogeneity; however, adequate macrophage isolations are difficult to acquire from inflamed tissues. In this protocol, we outline the isolation steps and necessary troubleshooting guidelines derived from our studies for obtaining a suitable population of tissue-resident macrophages from mice following 18 weeks of high-fat (HFD) or high-fat/high-cholesterol (HFHCD) diet intervention. This protocol focuses on three hallmark tissues studied in obesity and atherosclerosis including the liver, white adipose tissues (WAT), and the aorta. We highlight how dualistic usage of flow cytometry can achieve a new dimension of isolation and characterization of tissue-resident macrophages. A fundamental section of this protocol addresses the intricacies underlying tissue-specific enzymatic digestions and macrophage isolation, and subsequent cell-surface antibody staining for flow cytometric analysis. This protocol addresses existing complexities underlying fluorescent-activated cell sorting (FACS) and presents clarifications to these complexities so as to obtain broad range characterization from adequately sorted cell populations. Alternate enrichment methods are included for sorting cells, such as the dense liver, allowing for flexibility and time management when working with FACS. In brief, this protocol aids the researcher to evaluate macrophage heterogeneity from a multitude of inflamed tissues in a given study and provides insightful troubleshooting tips that have been successful for favorable cellular isolation and characterization of immune cells in DIO-mediated inflammation.

  2. Improved Process for Fabricating Carbon Nanotube Probes

    NASA Technical Reports Server (NTRS)

    Stevens, R.; Nguyen, C.; Cassell, A.; Delzeit, L.; Meyyappan, M.; Han, Jie

    2003-01-01

    An improved process has been developed for the efficient fabrication of carbon nanotube probes for use in atomic-force microscopes (AFMs) and nanomanipulators. Relative to prior nanotube tip production processes, this process offers advantages in alignment of the nanotube on the cantilever and stability of the nanotube's attachment. A procedure has also been developed at Ames that effectively sharpens the multiwalled nanotube, which improves the resolution of the multiwalled nanotube probes and, combined with the greater stability of multiwalled nanotube probes, increases the effective resolution of these probes, making them comparable in resolution to single-walled carbon nanotube probes. The robust attachment derived from this improved fabrication method and the natural strength and resiliency of the nanotube itself produces an AFM probe with an extremely long imaging lifetime. In a longevity test, a nanotube tip imaged a silicon nitride surface for 15 hours without measurable loss of resolution. In contrast, the resolution of conventional silicon probes noticeably begins to degrade within minutes. These carbon nanotube probes have many possible applications in the semiconductor industry, particularly as devices are approaching the nanometer scale and new atomic layer deposition techniques necessitate a higher resolution characterization technique. Previously at Ames, the use of nanotube probes has been demonstrated for imaging photoresist patterns with high aspect ratio. In addition, these tips have been used to analyze Mars simulant dust grains, extremophile protein crystals, and DNA structure.

  3. Evaluation of peak force of a manually operated chiropractic adjusting instrument with an adapter for use in animals.

    PubMed

    Duarte, Felipe Coutinho Kullmann; Kolberg, Carolina; Barros, Rodrigo R; Silva, Vivian G A; Gehlen, Günter; Vassoler, Jakson M; Partata, Wania A

    2014-05-01

    This study was designed to assess the peak force of a manually operated chiropractic adjusting instrument, the Activator Adjusting Instrument 4 (AAI 4), with an adapter for use in animals, which has a 3- to 4-fold smaller contact surface area than the original rubber tip. Peak force was determined by thrusting the AAI 4 with the adapter or the original rubber tip onto a load cell. First, the AAI 4 was applied perpendicularly by a doctor of chiropractic onto the load cell. Then, the AAI 4 was fixed in a rigid framework and applied to the load cell. This procedure was done to prevent any load on the load cell before the thrust impulse. In 2 situations, trials were performed with the AAI 4 at all force settings (settings I, II, III, and IV, minimum to maximum, respectively). A total of 50000 samples per second over a period of 3 seconds were collected. In 2 experimental protocols, the use of the adapter in the AAI 4 increased the peak force only with setting I. The new value was around 80% of the maximum value found for the AAI 4. Nevertheless, the peak force values of the AAI 4 with the adapter and with the original rubber tip in setting IV were similar. The adapter effectively determines the maximum peak force value at force setting I of AAI 4. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  4. Intelligent QoS routing algorithm based on improved AODV protocol for Ad Hoc networks

    NASA Astrophysics Data System (ADS)

    Huibin, Liu; Jun, Zhang

    2016-04-01

    Mobile Ad Hoc Networks were playing an increasingly important part in disaster reliefs, military battlefields and scientific explorations. However, networks routing difficulties are more and more outstanding due to inherent structures. This paper proposed an improved cuckoo searching-based Ad hoc On-Demand Distance Vector Routing protocol (CSAODV). It elaborately designs the calculation methods of optimal routing algorithm used by protocol and transmission mechanism of communication-package. In calculation of optimal routing algorithm by CS Algorithm, by increasing QoS constraint, the found optimal routing algorithm can conform to the requirements of specified bandwidth and time delay, and a certain balance can be obtained among computation spending, bandwidth and time delay. Take advantage of NS2 simulation software to take performance test on protocol in three circumstances and validate the feasibility and validity of CSAODV protocol. In results, CSAODV routing protocol is more adapt to the change of network topological structure than AODV protocol, which improves package delivery fraction of protocol effectively, reduce the transmission time delay of network, reduce the extra burden to network brought by controlling information, and improve the routing efficiency of network.

  5. Two-party quantum key agreement protocols under collective noise channel

    NASA Astrophysics Data System (ADS)

    Gao, Hao; Chen, Xiao-Guang; Qian, Song-Rong

    2018-06-01

    Recently, quantum communication has become a very popular research field. The quantum key agreement (QKA) plays an important role in the field of quantum communication, based on its unconditional security in terms of theory. Among all kinds of QKA protocols, QKA protocols resisting collective noise are widely being studied. In this paper, we propose improved two-party QKA protocols resisting collective noise and present a feasible plan for information reconciliation. Our protocols' qubit efficiency has achieved 26.67%, which is the best among all the two-party QKA protocols against collective noise, thus showing that our protocol can improve the transmission efficiency of quantum key agreement.

  6. Benefits of Improved HP Turbine Active Clearance Control

    NASA Technical Reports Server (NTRS)

    Ruiz, Rafael; Albers, Bob; Sak, Wojciech; Seitzer, Ken; Steinetz, Bruce M.

    2007-01-01

    As part of the NASA Propulsion 21 program, GE Aircraft Engines was contracted to develop an improved high pressure turbine(HPT) active clearance control (ACC) system. The system is envisioned to minimize blade tip clearances to improve HPT efficiency throughout the engine operation range simultaneously reducing fuel consumption and emissions.

  7. An improved method for chromosome counting in maize.

    PubMed

    Kato, A

    1997-09-01

    An improved method for counting chromosomes in maize (Zea mays L.) is presented. Application of cold treatment (5C, 24 hr), heat treatment (42 C, 5 min) and a second cold treatment (5C, 24 hr) to root tips before fixation increased the number of condensed and dispersed countable metaphase chromosome figures. Fixed root tips were prepared by the enzymatic maceration-air drying method and preparations were stained with acetic orcein. Under favorable conditions, one preparation with 50-100 countable chromosome figures could be obtained in diploid maize using this method. Conditions affecting the dispersion of the chromosomes are described. This technique is especially useful for determining the somatic chromosome number in triploid and tetraploid maize lines.

  8. An on-line calibration technique for improved blade by blade tip clearance measurement

    NASA Astrophysics Data System (ADS)

    Sheard, A. G.; Westerman, G. C.; Killeen, B.

    A description of a capacitance-based tip clearance measurement system which integrates a novel technique for calibrating the capacitance probe in situ is presented. The on-line calibration system allows the capacitance probe to be calibrated immediately prior to use, providing substantial operational advantages and maximizing measurement accuracy. The possible error sources when it is used in service are considered, and laboratory studies of performance to ascertain their magnitude are discussed. The 1.2-mm diameter FM capacitance probe is demonstrated to be insensitive to variations in blade tip thickness from 1.25 to 1.45 mm. Over typical compressor blading the probe's range was four times the variation in blade to blade clearance encountered in engine run components.

  9. Turbine blade cooling

    DOEpatents

    Staub, F.W.; Willett, F.T.

    1999-07-20

    A turbine rotor blade comprises a shank portion, a tip portion and an airfoil. The airfoil has a pressure side wall and a suction side wall that are interconnected by a plurality of partition sidewalls, defining an internal cooling passageway within the airfoil. The internal cooling passageway includes at least one radial outflow passageway to direct a cooling medium flow from the shank portion towards the tip portion and at least one radial inflow passageway to direct a cooling medium flow from the tip portion towards the shank portion. A number of mixing ribs are disposed on the partition sidewalls within the radial outflow passageways so as to enhance the thermal mixing of the cooling medium flow, thereby producing improved heat transfer over a broad range of the Buoyancy number. 13 figs.

  10. Rules of engagement-12 tips for successful use of "clickers" in the classroom.

    PubMed

    Premkumar, Kalyani; Coupal, Cyril

    2008-01-01

    Student response system or clickers is an electronic application where a receiver in the instructor's computer captures responses to questions from student keypads. Used effectively, clickers can promote learner engagement and serve to improve learning. It can be used in a variety of ways such as to provide feedback to learners and instructor, to start discussions, for peer evaluation, for formative and summative assessment, to build a learning community, and to experiment on human responses. Using our experience in the use of this technology and literature review, we provide twelve tips for successful use of the student response system. We have found these strategies useful and envisage that the application of these tips can help maximize learner engagement and learning.

  11. In-Process Atomic-Force Microscopy (AFM) Based Inspection

    PubMed Central

    Mekid, Samir

    2017-01-01

    A new in-process atomic-force microscopy (AFM) based inspection is presented for nanolithography to compensate for any deviation such as instantaneous degradation of the lithography probe tip. Traditional method used the AFM probes for lithography work and retract to inspect the obtained feature but this practice degrades the probe tip shape and hence, affects the measurement quality. This paper suggests a second dedicated lithography probe that is positioned back-to-back to the AFM probe under two synchronized controllers to correct any deviation in the process compared to specifications. This method shows that the quality improvement of the nanomachining, in progress probe tip wear, and better understanding of nanomachining. The system is hosted in a recently developed nanomanipulator for educational and research purposes. PMID:28561747

  12. Turbine blade cooling

    DOEpatents

    Staub, Fred Wolf; Willett, Fred Thomas

    1999-07-20

    A turbine rotor blade comprises a shank portion, a tip portion and an airfoil. The airfoil has a pressure side wall and a suction side wall that are interconnected by a plurality of partition sidewalls, defining an internal cooling passageway within the airfoil. The internal cooling passageway includes at least one radial outflow passageway to direct a cooling medium flow from the shank portion towards the tip portion and at least one radial inflow passageway to direct a cooling medium flow from the tip portion towards the shank portion. A number of mixing ribs are disposed on the partition sidewalls within the radial outflow passageways so as to enhance the thermal mixing of the cooling medium flow, thereby producing improved heat transfer over a broad range of the Buoyancy number.

  13. Turbine blade cooling

    DOEpatents

    Staub, Fred Wolf; Willett, Fred Thomas

    2000-01-01

    A turbine rotor blade comprises a shank portion, a tip portion and an airfoil. The airfoil has a pressure side wall and a suction side wall that are interconnected by a plurality of partition sidewalls, defining an internal cooling passageway within the airfoil. The internal cooling passageway includes at least one radial outflow passageway to direct a cooling medium flow from the shank portion towards the tip portion and at least one radial inflow passageway to direct a cooling medium flow from the tip portion towards the shank portion. A number of mixing ribs are disposed on the partition sidewalls within the radial outflow passageways so as to enhance the thermal mixing of the cooling medium flow, thereby producing improved heat transfer over a broad range of the Buoyancy number.

  14. Effect of In Situ Annealing Treatment on the Mobility and Morphology of TIPS-Pentacene-Based Organic Field-Effect Transistors.

    PubMed

    Yang, Fuqiang; Wang, Xiaolin; Fan, Huidong; Tang, Ying; Yang, Jianjun; Yu, Junsheng

    2017-08-23

    In this work, organic field-effect transistors (OFETs) with a bottom gate top contact structure were fabricated by using a spray-coating method, and the influence of in situ annealing treatment on the OFET performance was investigated. Compared to the conventional post-annealing method, the field-effect mobility of OFET with 60 °C in situ annealing treatment was enhanced nearly four times from 0.056 to 0.191 cm 2 /Vs. The surface morphologies and the crystallization of TIPS-pentacene films were characterized by optical microscope, atomic force microscope, and X-ray diffraction. We found that the increased mobility was mainly attributed to the improved crystallization and highly ordered TIPS-pentacene molecules.

  15. Effect of In Situ Annealing Treatment on the Mobility and Morphology of TIPS-Pentacene-Based Organic Field-Effect Transistors

    NASA Astrophysics Data System (ADS)

    Yang, Fuqiang; Wang, Xiaolin; Fan, Huidong; Tang, Ying; Yang, Jianjun; Yu, Junsheng

    2017-08-01

    In this work, organic field-effect transistors (OFETs) with a bottom gate top contact structure were fabricated by using a spray-coating method, and the influence of in situ annealing treatment on the OFET performance was investigated. Compared to the conventional post-annealing method, the field-effect mobility of OFET with 60 °C in situ annealing treatment was enhanced nearly four times from 0.056 to 0.191 cm2/Vs. The surface morphologies and the crystallization of TIPS-pentacene films were characterized by optical microscope, atomic force microscope, and X-ray diffraction. We found that the increased mobility was mainly attributed to the improved crystallization and highly ordered TIPS-pentacene molecules.

  16. Flow Instability and Flow Control Scaling Laws

    NASA Astrophysics Data System (ADS)

    van Ness, Daniel; Corke, Thomas; Morris, Scott

    2006-11-01

    A flow instability that is receptive to perturbations is present in the tip clearance leakage flow over the tip of a turbine blade. This instability was investigated through the introduction of active flow control in the viscous flow field. Control was implemented in the form of a dielectric barrier discharge created by a weakly-ionized plasma actuation arrangement. The experimental setup consisted of a low-speed linear turbine cascade made up of an array of nine Pratt & Whitney ``PakB'' turbine blades. This idealized cascade configuration was used to examine the tip clearance leakage flow that exists within the low pressure turbine stage of a gas-turbine engine. The center blade of the cascade array had a variable tip clearance up to five percent chord. Reynolds numbers based on axial blade chord varied from 10^4 to 10^5. Multi-port pressure probe measurements, as well as Stereo Particle Image Velocimetry were used to document the dependence of the instability on the frequency and amplitude of flow control perturbations. Scaling laws based on the variation of blade tip clearance height and inflow conditions were investigated. These results permitted an improved understanding of the mechanism of flow instability.

  17. A Novel SPM Probe with MOS Transistor and Nano Tip for Surface Electric Properties

    NASA Astrophysics Data System (ADS)

    Lee, Sang H.; Lim, Geunbae; Moon, Wonkyu

    2007-03-01

    In this paper, the novel SPM (Scanning Probe Microscope) probe with the planar MOS (Metal-Oxide-Semiconductor) transistor and the FIB (Focused Ion Beam) nano tip is fabricated for the surface electric properties. Since the MOS transistor has high working frequency, the device can overcome the speed limitation of EFM (Electrostatic Force Microscope) system. The sensitivity is also high, and no bulky device such as lock-in-amplifier is required. Moreover, the nano tip with nanometer scale tip radius is fabricated with FIB system, and the resolution can be improved. Therefore, the probe can rapidly detect small localized electric properties with high sensitivity and high resolution. The MOS transistor is fabricated with the common semiconductor process, and the nano tip is grown by the FIB system. The planar structure of the MOS transistor makes the fabrication process easier, which is the advantage on the commercial production. Various electric signals are applied using the function generator, and the measured data represent the well-established electric properties of the device. It shows the promising aspect of the local surface electric property detection with high sensitivity and high resolution.

  18. Cu2O-tipped ZnO nanorods with enhanced photoelectrochemical performance for CO2 photoreduction

    NASA Astrophysics Data System (ADS)

    Iqbal, Muzaffar; Wang, Yanjie; Hu, Haifeng; He, Meng; Hassan Shah, Aamir; Lin, Lin; Li, Pan; Shao, Kunjuan; Reda Woldu, Abebe; He, Tao

    2018-06-01

    The design of Cu2O-tipped ZnO nanorods is proposed here aiming at enhanced photoelectrochemical properties. The tip-selective deposition of Cu2O is confirmed by scanning transmission electron microscopy (STEM). The photoinduced charge behavior like charge generation, separation and transport has been thoroughly studied by UV-vis absorption analysis and different photoelectrochemical characterizations, including transient photocurrent, incident photon-to-current efficiency (IPCE), electrochemical impedance spectroscopy (EIS), intensity-modulated photocurrent spectroscopy (IMPS), and Mott-Schottky measurements. The photoelectrochemical characterizations clearly indicate that ZnO/Cu2O structures exhibit much higher performance than pristine ZnO, due to the formation of p-n junction, as well as the tip selective growth of Cu2O on ZnO. Photocatalytic CO2 reduction in aqueous solution under UV-visible light illumination shows that CO is the main product, and with the increase of the Cu2O content in the heterostructure, the CO yield increases. This work shows that Cu2O-tipped ZnO nanorods possess improved behavior of charge generation, separation and transport, which may work as a potential candidate for photocatalytic CO2 reduction.

  19. Are we all doing it wrong? Influence of stripping and cleaving methods of laser fibers on laser lithotripsy performance.

    PubMed

    Kronenberg, Peter; Traxer, Olivier

    2015-03-01

    We assessed whether stripping and cleaving the laser fiber tip with specialized tools, namely laser fiber strippers, or ceramic or metal scissors, would influence lithotripsy performance. Laser fiber tips were stripped with a specialized laser fiber stripper or remained coated. The tips were then cleaved with metal or ceramic scissors. Laser lithotripsy experiments were performed with the 4 fiber tip combinations using an automated laser fragmentation testing system with artificial stones made of plaster of Paris or BegoStone Plus (Bego, Lincoln, Rhode Island). High frequency-low pulse energy (20 Hz and 0.5 J) and low frequency-high pulse energy (5 Hz and 2.0 J) settings were used for 30 seconds. Fissure width, depth and volume, and laser fiber tip photos were analyzed. Coated laser fiber tips always achieved significantly higher ablation volumes (sometimes greater than 50%) than stripped laser fiber tips (p <0.00001) regardless of cleaving scissor type, stone material or lithotripter setting. Coated fiber tips cleaved with metal scissors ablated as well as those cleaved with ceramic scissors (p = 0.16). However, stripped fibers were much less ablative when they were cut with metal scissors compared to ceramic scissors (p <0.00001). Harder stone material decreased ablation volume (p <0.00001). Low frequency-high pulse energy settings were an average of 3 times more ablative than high frequency-low pulse energy settings (p <0.00001). Stripping the fibers, a harder stone material and low frequency-high pulse energy settings were associated with increased fiber tip degradation. Coated laser fibers provided better lithotripsy performance and metal scissors were as good as ceramic scissors to cleave coated fibers. This knowledge may improve and simplify the way that laser lithotripsy procedures are done worldwide. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  20. Gas turbine blade film cooling and blade tip heat transfer

    NASA Astrophysics Data System (ADS)

    Teng, Shuye

    The detailed heat transfer coefficient and film cooling effectiveness distributions as well as the detailed coolant jet temperature profiles on the suction side of a gas turbine blade were measured using a transient liquid crystal image method and a traversing cold wire and thermocouple probe, respectively. The blade has only one row of film holes near the gill hole portion on the suction side of the blade. The hole geometries studied include standard cylindrical holes and holes with diffuser shaped exit portion (i.e. fanshaped holes and laidback fanshaped holes). Tests were performed on a five-blade linear cascade in a low-speed wind tunnel. The mainstream Reynolds number based on cascade exit velocity was 5.3 x 105. The upstream unsteady wakes were simulated using a spoke-wheel type wake generator. The wake Strouhal number was kept at 0 and 0.1. The coolant blowing ratio was varied from 0.4 to 1.2. Results show that both expanded holes have significantly improved thermal protection over the surface downstream of the ejection location, particularly at high blowing ratios. However, the expanded hole injections induce earlier boundary layer transition to turbulence and enhance heat transfer coefficients at the latter part of the blade suction surface. In general, the unsteady wake tends to reduce film cooling effectiveness. Measurements of detailed heat transfer coefficient distributions on a turbine blade tip were performed in the same wind tunnel facility as above. The central blade had a variable tip gap clearance. Measurements were made at three different tip gap clearances of about 1.1%, 2.1%, and 3% of the blade span. Static pressure distributions were measured in the blade mid-span and on the shroud surface. Detailed heat transfer coefficient distributions were measured on the blade tip surface. Results show that reduced tip clearance leads to reduced heat transfer coefficient over the blade tip surface. Results also show that reduced tip clearance tends to weaken the unsteady wake effect on blade tip heat transfer.

  1. An Approach to Endovascular and Percutaneous Management of Transjugular Intrahepatic Portosystemic Shunt (TIPS) Dysfunction: A Pictorial Essay and Clinical Practice Algorithm.

    PubMed

    Pereira, Keith; Baker, Reginald; Salsamendi, Jason; Doshi, Mehul; Kably, Issam; Bhatia, Shivank

    2016-05-01

    Transjugular intrahepatic portosystemic shunts (TIPS) have evolved as an effective and durable nonsurgical option in the treatment of portal hypertension (PH). It has been shown to improve survival in decompensated cirrhosis and may also serve as a bridge to liver transplantation. In spite of the technical improvements in the procedure, problems occur with the shunt which jeopardizes effective treatment of the PH. Appropriate management is vital to ensure the longevity of the conduit. Shunt revision techniques include endovascular revision techniques and new shunt creation or, in the appropriate patients, alternative/rescue therapies. The ability of interventional radiologists to restore adequate TIPS function has enormous implications for quality of life with palliation, morbidity/mortality related to variceal bleeding and survival if transplant candidates can live long enough to receive a new liver. As such, it is imperative that these treatment strategies are understood and employed when these patients are encountered. In this review, the restoration of appropriate shunt function using various techniques will be discussed as they apply to a variety of clinical scenarios, based on literature. In addition, illustrative case examples highlighting our experience at an academic tertiary medical center will be included. It is the intent to have this document serve as a concise and informative reference to be used by those who may encounter patients with suboptimal functioning TIPS.

  2. The grinding tip of the sea urchin tooth exhibits exquisite control over calcite crystal orientation and Mg distribution

    PubMed Central

    Ma, Yurong; Aichmayer, Barbara; Paris, Oskar; Fratzl, Peter; Meibom, Anders; Metzler, Rebecca A.; Politi, Yael; Addadi, Lia; Gilbert, P. U. P. A.; Weiner, Steve

    2009-01-01

    The sea urchin tooth is a remarkable grinding tool. Even though the tooth is composed almost entirely of calcite, it is used to grind holes into a rocky substrate itself often composed of calcite. Here, we use 3 complementary high-resolution tools to probe aspects of the structure of the grinding tip: X-ray photoelectron emission spectromicroscopy (X-PEEM), X-ray microdiffraction, and NanoSIMS. We confirm that the needles and plates are aligned and show here that even the high Mg polycrystalline matrix constituents are aligned with the other 2 structural elements when imaged at 20-nm resolution. Furthermore, we show that the entire tooth is composed of 2 cooriented polycrystalline blocks that differ in their orientations by only a few degrees. A unique feature of the grinding tip is that the structural elements from each coaligned block interdigitate. This interdigitation may influence the fracture process by creating a corrugated grinding surface. We also show that the overall Mg content of the tooth structural elements increases toward the grinding tip. This probably contributes to the increasing hardness of the tooth from the periphery to the tip. Clearly the formation of the tooth, and the tooth tip in particular, is amazingly well controlled. The improved understanding of these structural features could lead to the design of better mechanical grinding and cutting tools. PMID:19332795

  3. The grinding tip of the sea urchin tooth exhibits exquisite control over calcite crystal orientation and Mg distribution.

    PubMed

    Ma, Yurong; Aichmayer, Barbara; Paris, Oskar; Fratzl, Peter; Meibom, Anders; Metzler, Rebecca A; Politi, Yael; Addadi, Lia; Gilbert, P U P A; Weiner, Steve

    2009-04-14

    The sea urchin tooth is a remarkable grinding tool. Even though the tooth is composed almost entirely of calcite, it is used to grind holes into a rocky substrate itself often composed of calcite. Here, we use 3 complementary high-resolution tools to probe aspects of the structure of the grinding tip: X-ray photoelectron emission spectromicroscopy (X-PEEM), X-ray microdiffraction, and NanoSIMS. We confirm that the needles and plates are aligned and show here that even the high Mg polycrystalline matrix constituents are aligned with the other 2 structural elements when imaged at 20-nm resolution. Furthermore, we show that the entire tooth is composed of 2 cooriented polycrystalline blocks that differ in their orientations by only a few degrees. A unique feature of the grinding tip is that the structural elements from each coaligned block interdigitate. This interdigitation may influence the fracture process by creating a corrugated grinding surface. We also show that the overall Mg content of the tooth structural elements increases toward the grinding tip. This probably contributes to the increasing hardness of the tooth from the periphery to the tip. Clearly the formation of the tooth, and the tooth tip in particular, is amazingly well controlled. The improved understanding of these structural features could lead to the design of better mechanical grinding and cutting tools.

  4. Teleoperation in surgical robotics--network latency effects on surgical performance.

    PubMed

    Lum, Mitchell J H; Rosen, Jacob; King, Hawkeye; Friedman, Diana C W; Lendvay, Thomas S; Wright, Andrew S; Sinanan, Mika N; Hannaford, Blake

    2009-01-01

    A teleoperated surgical robotic system allows surgical procedures to be conducted across long distances while utilizing wired and wireless communication with a wide spectrum of performance that may affect the outcome. An open architecture portable surgical robotic system (Raven) was developed for both open and minimally invasive surgery. The system has been the subject of an intensive telesurgical experimental protocol aimed at exploring the boundaries of the system and surgeon performance during a series of field experiments in extreme environments (desert and underwater) teleportation between US, Europe, and Japan as well as lab experiments under synthetic fixed time delay. One standard task (block transfer emulating tissue manipulation) of the Fundamentals of Laparoscopic Surgery (FLS) training kit was used for the experimental protocol. Network characterization indicated a typical time delay in the range of 16-172 ms in field experiments. The results of the lab experiments showed that the completion time of the task as well as the length of the tool tip trajectory significantly increased (alpha< 0.02) as time delay increased in the range of 0-0.5 sec increased. For teleoperation with a time delay of 0.25s and 0.5s the task completion time was lengthened by a factor of 1.45 and 2.04 with respect to no time delay, whereas the length of the tools' trajectory was increased by a factor of 1.28 and 1.53 with respect to no time delay. There were no statistical differences between experienced surgeons and non-surgeons in the number of errors (block drooping) as well as the completion time and the tool tip path length at different time delays.

  5. Note: High-speed Z tip scanner with screw cantilever holding mechanism for atomic-resolution atomic force microscopy in liquid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reza Akrami, Seyed Mohammad; Miyata, Kazuki; Asakawa, Hitoshi

    High-speed atomic force microscopy has attracted much attention due to its unique capability of visualizing nanoscale dynamic processes at a solid/liquid interface. However, its usability and resolution have yet to be improved. As one of the solutions for this issue, here we present a design of a high-speed Z-tip scanner with screw holding mechanism. We perform detailed comparison between designs with different actuator size and screw arrangement by finite element analysis. Based on the design giving the best performance, we have developed a Z tip scanner and measured its performance. The measured frequency response of the scanner shows a flatmore » response up to ∼10 kHz. This high frequency response allows us to achieve wideband tip-sample distance regulation. We demonstrate the applicability of the scanner to high-speed atomic-resolution imaging by visualizing atomic-scale calcite crystal dissolution process in water at 2 s/frame.« less

  6. Mechanical manipulation of magnetic nanoparticles by magnetic force microscopy

    NASA Astrophysics Data System (ADS)

    Liu, Jinyun; Zhang, Wenxiao; Li, Yiquan; Zhu, Hanxing; Qiu, Renxi; Song, Zhengxun; Wang, Zuobin; Li, Dayou

    2017-12-01

    A method has been developed in this work for the mechanical manipulation of magnetic nanoparticles (MNPs). A helical curve was designed as the capture path to pick up and remove the target nanoparticle on a mica surface by a magnetic probe based on the magnetic force microscope (MFM). There were magnetic, tangential and pushing forces acting on the target particle during the approaching process when the tip followed the helical curve as the capture path. The magnetic force was significant when the tip was closer to the particle. The target particle can be attached on the surface of the magnetic probe tip and then be picked up after the tip retracted from the mica surface. Theoretical analysis and experimental results were presented for the pick-up and removal of MNPs. With this method, the precision and flexibility of manipulation of MNPs were improved significantly compared to the pushing or sliding of the target object away from the corresponding original location following a planned path.

  7. Load Composition Model Workflow (BPA TIP-371 Deliverable 1A)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chassin, David P.; Cezar, Gustavo V.

    This project is funded under Bonneville Power Administration (BPA) Strategic Partnership Project (SPP) 17-005 between BPA and SLAC National Accelerator Laboratory. The project in a BPA Technology Improvement Project (TIP) that builds on and validates the Composite Load Model developed by the Western Electric Coordinating Council's (WECC) Load Modeling Task Force (LMTF). The composite load model is used by the WECC Modeling and Validation Work Group to study the stability and security of the western electricity interconnection. The work includes development of load composition data sets, collection of load disturbance data, and model development and validation. This work supports reliablemore » and economic operation of the power system. This report was produced for Deliverable 1A of the BPA TIP-371 Project entitled \\TIP 371: Advancing the Load Composition Model". The deliverable documents the proposed work ow for the Composite Load Model, which provides the basis for the instrumentation, data acquisition, analysis and data dissemination activities addressed by later phases of the project.« less

  8. Sub-millisecond ligand probing of cell receptors with multiple solution exchange

    PubMed Central

    Sylantyev, Sergiy; Rusakov, Dmitri A

    2013-01-01

    The accurate knowledge of receptor kinetics is crucial to our understanding of cell signal transduction in general and neural function in particular. The classical technique of probing membrane receptors on a millisecond scale involves placing a recording micropipette with a membrane patch in front of a double-barrel (θ-glass) application pipette mounted on a piezo actuator. Driven by electric pulses, the actuator can rapidly shift the θ-glass pipette tip, thus exposing the target receptors to alternating ligand solutions. However, membrane patches survive for only a few minutes, thus normally restricting such experiments to a single-application protocol. In order to overcome this deficiency, we have introduced pressurized supply microcircuits in the θ-glass channels, thus enabling repeated replacement of application solutions within 10–15 s. this protocol, which has been validated in our recent studies and takes 20–60 min to implement, allows the characterization of ligand-receptor interactions with high sensitivity, thereby also enabling a powerful paired-sample statistical design. PMID:23744290

  9. Six years' experience of tolerance induction in renal transplantation using stem cell therapy.

    PubMed

    Vanikar, Aruna V; Trivedi, Hargovind L; Thakkar, Umang G

    2018-02-01

    Tolerance induction (TI) has been attempted with chimerism/clonal deletion. We report results of TI protocol (TIP) using stem cell therapy (SCT) included adipose derived mesenchymal stem cells (AD-MSC) and hematopoietic stem cells (HSC) in 10 living-donor related renal transplantation (LDRT) patients under non-myeloablative conditioning with Bortezomib, Methylprednisone, rabbit-anti-thymoglobulin and Rituximab, without using conventional immunosuppression. Transplantation was performed following acceptable lymphocyte cross-match, flow cross-match, single antigen assay and negative mixed lymphocyte reaction (MLR). Monitoring included serum creatinine (SCr), donor specific antibodies (DSA) and MLR. Protocol biopsies were planned after 100days and yearly in willing patients. Rescue immunosuppression was planned for rejection/DSA/positive MLR. Over mean 6±0.37year follow-up patient survival was 80% and death-censored graft survival was 90%. Mean SCr was 1.44±0.41mg/dL. This is the first clinical report of sustained TI in LDRT for 6years using SCT. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Assessing Mitochondrial Bioenergetics in Isolated Mitochondria from Various Mouse Tissues Using Seahorse XF96 Analyzer.

    PubMed

    Iuso, Arcangela; Repp, Birgit; Biagosch, Caroline; Terrile, Caterina; Prokisch, Holger

    2017-01-01

    Working with isolated mitochondria is the gold standard approach to investigate the function of the electron transport chain in tissues, free from the influence of other cellular factors. In this chapter, we outline a detailed protocol to measure the rate of oxygen consumption (OCR) with the high-throughput analyzer Seahorse XF96. More importantly, this protocol wants to provide practical tips for handling many different samples at once, and take a real advantage of using a high-throughput system. As a proof of concept, we have isolated mitochondria from brain, heart, liver, muscle, kidney, and lung of a wild-type mouse, and measured basal respiration (State II), ADP-stimulated respiration (State III), non-ADP-stimulated respiration (State IV o ), and FCCP-stimulated respiration (State III u ) using respiratory substrates specific to the respiratory chain complex I (RCCI) and complex II (RCCII). Mitochondrial purification and Seahorse runs were performed in less than eight working hours.

  11. Correlative and integrated light and electron microscopy of in-resin GFP fluorescence, used to localise diacylglycerol in mammalian cells

    PubMed Central

    Peddie, Christopher J.; Blight, Ken; Wilson, Emma; Melia, Charlotte; Marrison, Jo; Carzaniga, Raffaella; Domart, Marie-Charlotte; O׳Toole, Peter; Larijani, Banafshe; Collinson, Lucy M.

    2014-01-01

    Fluorescence microscopy of GFP-tagged proteins is a fundamental tool in cell biology, but without seeing the structure of the surrounding cellular space, functional information can be lost. Here we present a protocol that preserves GFP and mCherry fluorescence in mammalian cells embedded in resin with electron contrast to reveal cellular ultrastructure. Ultrathin in-resin fluorescence (IRF) sections were imaged simultaneously for fluorescence and electron signals in an integrated light and scanning electron microscope. We show, for the first time, that GFP is stable and active in resin sections in vacuo. We applied our protocol to study the subcellular localisation of diacylglycerol (DAG), a modulator of membrane morphology and membrane dynamics in nuclear envelope assembly. We show that DAG is localised to the nuclear envelope, nucleoplasmic reticulum and curved tips of the Golgi apparatus. With these developments, we demonstrate that integrated imaging is maturing into a powerful tool for accurate molecular localisation to structure. PMID:24637200

  12. Preparation and Fluorescent Analysis of Plant Metaphase Chromosomes.

    PubMed

    Schwarzacher, Trude

    2016-01-01

    Good preparations are essential for informative analysis of both somatic and meiotic chromosomes, cytogenetics, and cell divisions. Fluorescent chromosome staining allows even small chromosomes to be visualized and counted, showing their morphology. Aneuploidies and polyploidies can be established for species, populations, or individuals while changes occurring in breeding lines during hybridization or tissue culture and transformation protocols can be assessed. The process of division can be followed during mitosis and meiosis including pairing and chiasma distribution, as well as DNA organization and structure during the evolution of chromosomes can be studied. This chapter presents protocols for pretreatment and fixation of material, including tips of how to grow plants to get good and healthy meristem with many divisions. The chromosome preparation technique is described using proteolytic enzymes, but acids can be used instead. Chromosome slide preparations are suitable for fluorochrome staining for fast screening (described in the chapter) or fluorescent in situ hybridization (see Schwarzacher and Heslop-Harrison, In situ hybridization. BIOS Scientific Publishers, Oxford, 2000).

  13. Microneedle-based analysis of the micromechanics of the metaphase spindle assembled in Xenopus laevis egg extracts

    PubMed Central

    Shimamoto, Yuta; Kapoor, Tarun M.

    2014-01-01

    SUMMARY To explain how micron-sized cellular structures generate and respond to forces we need to characterize their micromechanical properties. Here we provide a protocol to build and use a dual force-calibrated microneedle-based set-up to quantitatively analyze the micromechanics of a metaphase spindle assembled in Xenopus laevis egg extracts. This cell-free extract system allows for controlled biochemical perturbations of spindle components. We describe how the microneedles are prepared and how they can be used to apply and measure forces. A multi-mode imaging system allows tracking of microtubules, chromosomes and needle tips. This set-up can be used to analyze the viscoelastic properties of the spindle on time-scales ranging from minutes to sub-seconds. A typical experiment, along with data analysis, is also detailed. We anticipate that our protocol can be readily extended to analyze the micromechanics of other cellular structures assembled in cell-free extracts. The entire procedure can take 3-4 days. PMID:22538847

  14. Scalability enhancement of AODV using local link repairing

    NASA Astrophysics Data System (ADS)

    Jain, Jyoti; Gupta, Roopam; Bandhopadhyay, T. K.

    2014-09-01

    Dynamic change in the topology of an ad hoc network makes it difficult to design an efficient routing protocol. Scalability of an ad hoc network is also one of the important criteria of research in this field. Most of the research works in ad hoc network focus on routing and medium access protocols and produce simulation results for limited-size networks. Ad hoc on-demand distance vector (AODV) is one of the best reactive routing protocols. In this article, modified routing protocols based on local link repairing of AODV are proposed. Method of finding alternate routes for next-to-next node is proposed in case of link failure. These protocols are beacon-less, means periodic hello message is removed from the basic AODV to improve scalability. Few control packet formats have been changed to accommodate suggested modification. Proposed protocols are simulated to investigate scalability performance and compared with basic AODV protocol. This also proves that local link repairing of proposed protocol improves scalability of the network. From simulation results, it is clear that scalability performance of routing protocol is improved because of link repairing method. We have tested protocols for different terrain area with approximate constant node densities and different traffic load.

  15. Data dissemination using gossiping in wireless sensor networks

    NASA Astrophysics Data System (ADS)

    Medidi, Muralidhar; Ding, Jin; Medidi, Sirisha

    2005-06-01

    Disseminating data among sensors is a fundamental operation in energy-constrained wireless sensor networks. We present a gossip-based adaptive protocol for data dissemination to improve energy efficiency of this operation. To overcome the data implosion problems associated with dissemination operation, our protocol uses meta-data to name the data using high-level data descriptors and negotiation to eliminate redundant transmissions of duplicate data in the network. Further, we adapt the gossiping with data aggregation possibilities in sensor networks. We simulated our data dissemination protocol, and compared it to the SPIN protocol. We find that our protocol improves on the energy consumption by about 20% over others, while improving significantly over the data dissemination rate of gossiping.

  16. In-plane ultrasonic needle tracking using a fiber-optic hydrophone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E.; Mari, Jean Martial

    Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction withmore » the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle. With the needle tip in water, the SNR of the needle tip varied with insertion angle, attaining values of 284 at 27° and 501 at 68°. In swine tissue ex vivo, the SNR decreased from 80 at 15° to 16 at 61°. In swine tissue in vivo, the SNR varied with depth, from 200 at 17.5 mm to 48 at 26 mm, with a constant insertion angle of 40°. In ovine tissue in vivo, within the uterine cavity, the SNR varied from 46.4 at 25 mm depth to 18.4 at 32 mm depth, with insertion angles in the range of 26°–65°. Conclusions: A fiber-optic ultrasound receiver integrated into the needle cannula in combination with single-element transmissions from the imaging probe allows for direct visualization of the needle tip within the ultrasound imaging plane. Visualization of the needle tip was achieved at depths and insertion angles that are encountered during nerve blocks and fetal interventions. The method presented in this paper has strong potential to improve the safety and efficiency of ultrasound-guided needle insertions.« less

  17. Abbreviated breast magnetic resonance protocol: Value of high-resolution temporal dynamic sequence to improve lesion characterization.

    PubMed

    Oldrini, Guillaume; Fedida, Benjamin; Poujol, Julie; Felblinger, Jacques; Trop, Isabelle; Henrot, Philippe; Darai, Emile; Thomassin-Naggara, Isabelle

    2017-10-01

    To evaluate the added value of ULTRAFAST-MR sequence to an abbreviated FAST protocol in comparison with FULL protocol to distinguish benign from malignant lesions in a population of women, regardless of breast MR imaging indication. From March 10th to September 22th, 2014, we retrospectively included a total of 70 consecutive patients with 106 histologically proven lesions (58 malignant and 48 benign) who underwent breast MR imaging for preoperative breast staging (n=38), high-risk screening (n=7), problem solving (n=18), and nipple discharge (n=4) with 12 time resolved imaging of contrast kinetics (TRICKS) acquisitions during contrast inflow interleaved in a regular high-resolution dynamic MRI protocol (FULL protocol). Two readers scored MR exams as either positive or negative and described significant lesions according to Bi-RADS lexicon with a TRICKS images (ULTRAFAST), an abbreviated protocol (FAST) and all images (FULL protocol). Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated for each protocol and compared with McNemar's test. For all readers, the combined FAST-ULTRAFAST protocol significantly improved the reading with a specificity of 83.3% and 70.8% in comparison with FAST protocol or FULL protocol, respectively, without change in sensitivity. By adding ULTRAFAST protocol to FAST protocol, readers 1 and 2 were able to correctly change the diagnosis in 22.9% (11/48) and 10.4% (5/48) of benign lesions, without missing any malignancy, respectively. Both interpretation and image acquisition times for combined FAST-ULTRAFAST protocol and FAST protocol were shorter compared to FULL protocol (p<0.001). Compared to FULL protocol, adding ULTRAFAST to FAST protocol improves specificity, mainly in correctly reclassifying benign masses and reducing interpretation and acquisition time, without decreasing sensitivity. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Improved efficiency of ZnO hierarchical particle based dye sensitized solar cell by incorporating thin passivation layer in photo-anode

    NASA Astrophysics Data System (ADS)

    Das, Priyanka; Mondal, Biswanath; Mukherjee, Kalisadhan

    2018-01-01

    Present article describes the DSSC performances of photo-anodes prepared using hydrothermal route derived ZnO particles having dissimilar morphologies i.e. simple micro-rod and nano-tips decorated micro-rod. The surface of nano-tips decorated micro-rod is uneven and patterned which facilitate more dye adsorption and better scattering of the incident light resulting superior photo-conversion efficiency (PCE) ( η 1.09%) than micro-rod ZnO ( η 0.86%). To further improve the efficiency of nano-tips decorated micro-rod ZnO based DSSC, thin passivation layer of ZnO is introduced in the corresponding photo-anode and a higher PCE ( η 1.29%) is achieved. The compact thin passivation layer here expedites the transportation of photo-excited electrons, restricts the undesired recombination reactions and prevents the direct contact of electrolyte with conducting substrates. Attempt is made to understand the effect of passivation layer on the transportation kinetics of photo-excited electrons by analyzing the electrochemical impedance spectra of the developed cells.

  19. Blade Vibration Measurement System

    NASA Technical Reports Server (NTRS)

    Platt, Michael J.

    2014-01-01

    The Phase I project successfully demonstrated that an advanced noncontacting stress measurement system (NSMS) could improve classification of blade vibration response in terms of mistuning and closely spaced modes. The Phase II work confirmed the microwave sensor design process, modified the sensor so it is compatible as an upgrade to existing NSMS, and improved and finalized the NSMS software. The result will be stand-alone radar/tip timing radar signal conditioning for current conventional NSMS users (as an upgrade) and new users. The hybrid system will use frequency data and relative mode vibration levels from the radar sensor to provide substantially superior capabilities over current blade-vibration measurement technology. This frequency data, coupled with a reduced number of tip timing probes, will result in a system capable of detecting complex blade vibrations that would confound traditional NSMS systems. The hardware and software package was validated on a compressor rig at Mechanical Solutions, Inc. (MSI). Finally, the hybrid radar/tip timing NSMS software package and associated sensor hardware will be installed for use in the NASA Glenn spin pit test facility.

  20. Improvement of "Novel Multiparty Quantum Key Agreement Protocol with GHZ States"

    NASA Astrophysics Data System (ADS)

    Gu, Jun; Hwang, Tzonelih

    2017-10-01

    Quantum key agreement (QKA) protocol is a method for negotiating a fair and secure key among mutually untrusted participants. Recently, Xu et al. (Quantum Inf. Process. 13:2587-2594, 2014) proposed a multi-party QKA protocol based on Greenberger-Horne-Zeilinger (GHZ) states. However, this study points out that Xu et al.'s protocol cannot provide the fairness property. That is, the last involved participant in the protocol can manipulate the final shared secret key without being detected by the other participants. Moreover, according to Yu et al.'s research (2015), Xu et al.'s protocol cannot avoid the public discussion attack too. To avoid these weaknesses, an improved QKA protocol is proposed.

  1. Development of a Tip-Enhanced Near-Field Optical Microscope for Nanoscale Interrogation of Surface Chemistry and Plasmonic Phenomena

    NASA Astrophysics Data System (ADS)

    Heilman, Alexander Lee

    Optical microscopy and spectroscopy are invaluable tools for the physical and chemical characterization of materials and surfaces in a wide range of scientific disciplines. However, the application of conventional optical methods in the study of nanomaterials is inherently limited by diffraction. Tip-enhanced near-field optical microscopy (TENOM) is a hybrid technique that marries optical spectroscopy with scanning probe microscopy to overcome the spatial resolution limit imposed by diffraction. By coupling optical energy into the plasmonic modes of a sharp metal probe tip, a strong, localized optical field is generated near the tip's apex and is used to enhance spectroscopic emissions within a sub-diffraction-limited volume. In this thesis, we describe the design, construction, validation, and application of a custom TENOM instrument with a unique attenuated total reflectance (ATR)-geometry excitation/detection system. The specific goals of this work were: (i) to develop a versatile TENOM instrument capable of investigating a variety of optical phenomena at the nanoscale, (ii) to use the instrument to demonstrate chemical interrogation of surfaces with sub-diffraction-limited spatial resolution (i.e., at super resolution), (iii) to apply the instrument to study plasmonic phenomena that influence spectroscopic enhancement in TENOM measurements, and (iv) to leverage resulting insights to develop systematic improvements that expand the ultimate capabilities of near-field optical interrogation techniques. The TENOM instrument described herein is comprised of three main components: an atomic force microscope (AFM), a side-on confocal Raman microscope, and a novel ATR excitation/detection system. The design of each component is discussed along with the results of relevant validation experiments, which were performed to rigorously assess each component's performance. Finite-difference time-domain (FDTD) optical simulations were also developed and used extensively to evaluate the results of validation studies and to optimize experimental design and instrument performance. By combining and synchronizing the operation of the instrument's three components, we perform a variety of near-field optical experiments that demonstrate the instrument's functionality and versatility. ATR illumination is combined with a plasmonic AFM tip to show that: (i) the tip can quantitatively transduce the optical near-field (evanescent waves) above the surface by scattering photons into the far-field, (ii) the ATR geometry enables excitation and characterization of surface plasmon polaritons (SPPs), whose associated optical fields are shown to enhance Raman scattering from a thin layer of copper phthalocyanine (CuPc), and (iii) SPPs can be used to plasmonically excite the tip for super-resolution chemical imaging of patterned CuPc via tip-enhanced Raman spectroscopy (TERS). ATR-illumination TERS is quantitatively compared with side-on illumination. In both cases, spatial resolution was better than 40 nm and tip-on/tip-off Raman enhancement factors were >6500. Furthermore, ATR illumination was shown to provide similar Raman signal levels at lower "effective'' pump powers due to additional optical energy delivered by SPPs to the active region in the tip-surface gap. We also investigate the sensitivity of the TENOM instrument to changes in the plasmonic properties of the tip-surface system in the strongly-coupled regime at small tip-surface separations. Specifically, we demonstrate detection of a resonant plasmonic tip-surface mode (a gap plasmon) that dramatically influences the optical response of the system, and we use experimental results and FDTD simulations to support a hypothesized mechanism. Moreover, we confirm that the gap plasmon resonance has a strong effect on the enhancement of both fluorescence and Raman scattering, and we propose that this phenomenon could ultimately be exploited to improve sensitivity in super-resolution chemical imaging measurements. Finally, we recommend a straightforward modification to the TENOM instrument that could enable future application of these gap-mode plasmon resonances to increase spectroscopic enhancements by an order of magnitude.

  2. Noise reduction and functional maps image quality improvement in dynamic CT perfusion using a new k-means clustering guided bilateral filter (KMGB).

    PubMed

    Pisana, Francesco; Henzler, Thomas; Schönberg, Stefan; Klotz, Ernst; Schmidt, Bernhard; Kachelrieß, Marc

    2017-07-01

    Dynamic CT perfusion (CTP) consists in repeated acquisitions of the same volume in different time steps, slightly before, during and slightly afterwards the injection of contrast media. Important functional information can be derived for each voxel, which reflect the local hemodynamic properties and hence the metabolism of the tissue. Different approaches are being investigated to exploit data redundancy and prior knowledge for noise reduction of such datasets, ranging from iterative reconstruction schemes to high dimensional filters. We propose a new spatial bilateral filter which makes use of the k-means clustering algorithm and of an optimal calculated guiding image. We named the proposed filter as k-means clustering guided bilateral filter (KMGB). In this study, the KMGB filter is compared with the partial temporal non-local means filter (PATEN), with the time-intensity profile similarity (TIPS) filter, and with a new version derived from it, by introducing the guiding image (GB-TIPS). All the filters were tested on a digital in-house developed brain CTP phantom, were noise was added to simulate 80 kV and 200 mAs (default scanning parameters), 100 mAs and 30 mAs. Moreover, the filters performances were tested on 7 noisy clinical datasets with different pathologies in different body regions. The original contribution of our work is two-fold: first we propose an efficient algorithm to calculate a guiding image to improve the results of the TIPS filter, secondly we propose the introduction of the k-means clustering step and demonstrate how this can potentially replace the TIPS part of the filter obtaining better results at lower computational efforts. As expected, in the GB-TIPS, the introduction of the guiding image limits the over-smoothing of the TIPS filter, improving spatial resolution by more than 50%. Furthermore, replacing the time-intensity profile similarity calculation with a fuzzy k-means clustering strategy (KMGB) allows to control the edge preserving features of the filter, resulting in improved spatial resolution and CNR both for CT images and for functional maps. In the phantom study, the PATEN filter showed overall the poorest results, while the other filters showed comparable performances in terms of perfusion values preservation, with the KMGB filter having overall the best image quality. In conclusion, the KMGB filter leads to superior results for CT images and functional maps quality improvement, in significantly shorter computational times compared to the other filters. Our results suggest that the KMGB filter might be a more robust solution for halved-dose CTP datasets. For all the filters investigated, some artifacts start to appear on the BF maps if one sixth of the dose is simulated, suggesting that no one of the filters investigated in this study might be optimal for such a drastic dose reduction scenario. © 2017 American Association of Physicists in Medicine.

  3. Raising orphans from a metadata morass: A researcher's guide to re-use of public 'omics data.

    PubMed

    Bhandary, Priyanka; Seetharam, Arun S; Arendsee, Zebulun W; Hur, Manhoi; Wurtele, Eve Syrkin

    2018-02-01

    More than 15 petabases of raw RNAseq data is now accessible through public repositories. Acquisition of other 'omics data types is expanding, though most lack a centralized archival repository. Data-reuse provides tremendous opportunity to extract new knowledge from existing experiments, and offers a unique opportunity for robust, multi-'omics analyses by merging metadata (information about experimental design, biological samples, protocols) and data from multiple experiments. We illustrate how predictive research can be accelerated by meta-analysis with a study of orphan (species-specific) genes. Computational predictions are critical to infer orphan function because their coding sequences provide very few clues. The metadata in public databases is often confusing; a test case with Zea mays mRNA seq data reveals a high proportion of missing, misleading or incomplete metadata. This metadata morass significantly diminishes the insight that can be extracted from these data. We provide tips for data submitters and users, including specific recommendations to improve metadata quality by more use of controlled vocabulary and by metadata reviews. Finally, we advocate for a unified, straightforward metadata submission and retrieval system. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Micropropagation of Phalaenopsis orchids via protocorms and protocorm-like bodies.

    PubMed

    Paek, Kee Yoeup; Hahn, Eun Joo; Park, So Young

    2011-01-01

    Phalaenopsis orchids have high economic value in the floriculture industry. Hybridization or cross-pollination in the breeding program have proven to be very reliable techniques for the production of a wide range of successful cultivars with attractive combinations of spray length, bud number, flower color and type, fragrance, seasonality, and compactness. In vitro propagation makes it possible to clonally mass propagate hybrids of commercial value and conserved species. However, in vitro culture technologies are still a challenge because of the slow growth of plantlets, low multiplication rate, poor rooting, and somaclonal variation. Although seed-raised plants can be used for conservation and breeding for the selection of superior features, genetic characteristics including seasonality, inflorescence, flower color, and type are not uniform. In this regard, micropropagation through protocorm-like bodies obtained from germinating embryos and somatic tissues is an important strategy in obtaining genetically stable plants and the improvement of quality. However, not all genotypes of Phalaenopsis respond to the same protocol under the same culture conditions and often result in the development of undesirable characteristics. In this chapter, plantlet production in Phalaenopsis orchids via the culture of protocorms from seeds and protocorm-like bodies from leaf sections and root tips are detailed.

  5. Twelve tips for medical students to establish a collaborative flashcard project.

    PubMed

    Hart-Matyas, Michael; Taylor, Alexandra; Lee, Han Joo; Maclean, Mark A; Hui, Amaris; Macleod, Anna

    2018-01-29

    Medical students employ various study strategies to master large amounts of information during their medical education. Digital flashcards are an interactive, self-directed study stool that may improve knowledge retention by combining the principles of active recall and spaced-repetition. They may be studied during and beyond undergraduate medical education. However, making flashcards can be an onerous task. In this article, we describe twelve tips on how to establish and maintain a collaborative digital flashcard project based on the undergraduate medical curriculum.

  6. Error Estimation and Compensation in Reduced Dynamic Models of Large Space Structures

    DTIC Science & Technology

    1987-04-23

    PROCUREMENT INSTRUMENT IDENTIFICATION NUMBER ORGANIZATION (if aplicable ) AFWAL I FIBRA F33615-84-C-3219 8c. ADDRESS (City, Stateand ZIP Code) ?0 SOURCE...10 Modes of the Full Model 15 5 Comparison of Various Reduced Models 18 6 Driving Point Mobilities , Wing Tip (Z55) 19 7 Driving Point Mobilities , Wing...Root Trailing Edge (Z19) 20 8 AMI Improvement 23 9 Frequency Domain Solution, Driving Point Mobilities , Wing Tip (Z55), RM1I 25 10 Frequency Domain

  7. Effect of IOP based infusion system with and without balanced phaco tip on cumulative dissipated energy and estimated fluid usage in comparison to gravity fed infusion in torsional phacoemulsification.

    PubMed

    Malik, Praveen K; Dewan, Taru; Patidar, Arun Kr; Sain, Ekta

    2017-01-01

    To evaluate the effect of three different combinations of tip designs and infusion systems in torsional phacoemulsification (INFINITI and CENTURION) in patients with cataract. According to the manufacturer, two unique improvements in the Centurion are: active fluid dynamic management system and use of an intrepid balanced tip. The study specifically aimed to evaluate the beneficial effects, if any, of change in tip design and infusion system individually and in combination on both per-operative parameters as well as endothelial health over 6 months. One hundred and twenty six consenting patients of grade 4.0-6.9 senile cataract were randomized into three groups for phacoemulsification: Group A ( n  = 42): Gravity fed infusion system and 45 0 Kelman miniflared ABS phaco tip; Group B ( n  = 42): intraocular pressure (IOP) based infusion system and 45 0 Kelman miniflared ABS phaco tip; Group C ( n  = 42): IOP based infusion system and 45 0 Intrepid balanced phaco tip. The cumulative dissipated energy (CDE), estimated fluid usage (EFU) and total aspiration time (TAT) were compared peroperatively. The endothelial parameters were followed up postoperatively for six months. The three arms were matched for age ( p  = 0.525), gender ( p  = 0.96) and grade of cataract ( p  = 0.177). Group C was associated with significant reductions in CDE ( p  = 0.001), EFU ( p  < 0.0005) as well as TAT ( p  = 0.001) in comparison to the other groups. All three groups had comparable baseline endothelial cell density ( p  = 0.876) and central corneal thickness ( p  = 0.561). On post-operative evaluation, although all groups were comparable till 3 months, by 6 months, the percentage losses in endothelial cell density were significantly lower in group C as compared to the other groups. Use of an IOP based phacoemulsification system in association with use of the Intrepid balanced tip reduces the CDE, EFU and TAT in comparison to a gravity fed system with a mini flared tip or IOP based system with a mini flared tip while also providing better endothelial preservation thus favouring the use of an IOP fed system with a balanced tip. Trial registration No.: CTRI/2016/06/007022.

  8. AIB-OR: improving onion routing circuit construction using anonymous identity-based cryptosystems.

    PubMed

    Wang, Changji; Shi, Dongyuan; Xu, Xilei

    2015-01-01

    The rapid growth of Internet applications has made communication anonymity an increasingly important or even indispensable security requirement. Onion routing has been employed as an infrastructure for anonymous communication over a public network, which provides anonymous connections that are strongly resistant to both eavesdropping and traffic analysis. However, existing onion routing protocols usually exhibit poor performance due to repeated encryption operations. In this paper, we first present an improved anonymous multi-receiver identity-based encryption (AMRIBE) scheme, and an improved identity-based one-way anonymous key agreement (IBOWAKE) protocol. We then propose an efficient onion routing protocol named AIB-OR that provides provable security and strong anonymity. Our main approach is to use our improved AMRIBE scheme and improved IBOWAKE protocol in onion routing circuit construction. Compared with other onion routing protocols, AIB-OR provides high efficiency, scalability, strong anonymity and fault tolerance. Performance measurements from a prototype implementation show that our proposed AIB-OR can achieve high bandwidths and low latencies when deployed over the Internet.

  9. AIB-OR: Improving Onion Routing Circuit Construction Using Anonymous Identity-Based Cryptosystems

    PubMed Central

    Wang, Changji; Shi, Dongyuan; Xu, Xilei

    2015-01-01

    The rapid growth of Internet applications has made communication anonymity an increasingly important or even indispensable security requirement. Onion routing has been employed as an infrastructure for anonymous communication over a public network, which provides anonymous connections that are strongly resistant to both eavesdropping and traffic analysis. However, existing onion routing protocols usually exhibit poor performance due to repeated encryption operations. In this paper, we first present an improved anonymous multi-receiver identity-based encryption (AMRIBE) scheme, and an improved identity-based one-way anonymous key agreement (IBOWAKE) protocol. We then propose an efficient onion routing protocol named AIB-OR that provides provable security and strong anonymity. Our main approach is to use our improved AMRIBE scheme and improved IBOWAKE protocol in onion routing circuit construction. Compared with other onion routing protocols, AIB-OR provides high efficiency, scalability, strong anonymity and fault tolerance. Performance measurements from a prototype implementation show that our proposed AIB-OR can achieve high bandwidths and low latencies when deployed over the Internet. PMID:25815879

  10. The latest generation in flexible bronchoscopes: a description and evaluation.

    PubMed

    Hsia, David W; Tanner, Nichole T; Shamblin, Clayton; Mehta, Hiren J; Silvestri, Gerard A; Musani, Ali I

    2013-10-01

    Since the introduction of the flexible bronchoscope over 50 years ago, bronchoscopists have seen vast improvement in the technology available for diagnostics and therapeutics in the bronchoscopy laboratory. We set forth to evaluate the latest evolution in flexible bronchoscopes with features designed to improve imaging and airway navigation. The BF-Q190, BF-H190, and/or BF-1TH190 bronchoscopes were evaluated prospectively in 105 patients undergoing bronchoscopy from November 2010 to August 2011 at 2 tertiary care centers in the United States. Data collected from each procedure included method of insertion, airway images, and therapeutic interventions. At the completion of the study, 10 bronchoscopists were surveyed using a 7-point Likert scale to identify the perceived benefits of the design. Insertion methods included nasal, oral, laryngeal mask airway or endotracheal tube, and tracheostomy. Procedures performed included bronchoalveolar lavage, endobronchial biopsy or brushing, transbronchial biopsy, transbronchial needle aspiration or injection, peripheral navigation, and large airway therapeutic interventions. Survey of bronchoscopists revealed that when compared with current bronchoscopes, the features rated as having the most significant impact on functionality are the 210-degree tip angulation (average 2.4/3) and rotational capability of the insertion tube (average 2.4/3). The new-generation flexible bronchoscope offers improvement in image quality, magnification options, unique insertion tube rotation, and an increased 210-degree distal tip angulation over currently available flexible bronchoscopes. The bronchoscopes are an overall improvement to the current generation of bronchoscopes. The increased tip angulation and novel rotating insertion tube add the most to improvement in functionality.

  11. Security Enhanced User Authentication Protocol for Wireless Sensor Networks Using Elliptic Curves Cryptography

    PubMed Central

    Choi, Younsung; Lee, Donghoon; Kim, Jiye; Jung, Jaewook; Nam, Junghyun; Won, Dongho

    2014-01-01

    Wireless sensor networks (WSNs) consist of sensors, gateways and users. Sensors are widely distributed to monitor various conditions, such as temperature, sound, speed and pressure but they have limited computational ability and energy. To reduce the resource use of sensors and enhance the security of WSNs, various user authentication protocols have been proposed. In 2011, Yeh et al. first proposed a user authentication protocol based on elliptic curve cryptography (ECC) for WSNs. However, it turned out that Yeh et al.'s protocol does not provide mutual authentication, perfect forward secrecy, and key agreement between the user and sensor. Later in 2013, Shi et al. proposed a new user authentication protocol that improves both security and efficiency of Yeh et al.'s protocol. However, Shi et al.'s improvement introduces other security weaknesses. In this paper, we show that Shi et al.'s improved protocol is vulnerable to session key attack, stolen smart card attack, and sensor energy exhausting attack. In addition, we propose a new, security-enhanced user authentication protocol using ECC for WSNs. PMID:24919012

  12. Security enhanced user authentication protocol for wireless sensor networks using elliptic curves cryptography.

    PubMed

    Choi, Younsung; Lee, Donghoon; Kim, Jiye; Jung, Jaewook; Nam, Junghyun; Won, Dongho

    2014-06-10

    Wireless sensor networks (WSNs) consist of sensors, gateways and users. Sensors are widely distributed to monitor various conditions, such as temperature, sound, speed and pressure but they have limited computational ability and energy. To reduce the resource use of sensors and enhance the security of WSNs, various user authentication protocols have been proposed. In 2011, Yeh et al. first proposed a user authentication protocol based on elliptic curve cryptography (ECC) for WSNs. However, it turned out that Yeh et al.'s protocol does not provide mutual authentication, perfect forward secrecy, and key agreement between the user and sensor. Later in 2013, Shi et al. proposed a new user authentication protocol that improves both security and efficiency of Yeh et al.'s protocol. However, Shi et al.'s improvement introduces other security weaknesses. In this paper, we show that Shi et al.'s improved protocol is vulnerable to session key attack, stolen smart card attack, and sensor energy exhausting attack. In addition, we propose a new, security-enhanced user authentication protocol using ECC for WSNs.

  13. An improved PRoPHET routing protocol in delay tolerant network.

    PubMed

    Han, Seung Deok; Chung, Yun Won

    2015-01-01

    In delay tolerant network (DTN), an end-to-end path is not guaranteed and packets are delivered from a source node to a destination node via store-carry-forward based routing. In DTN, a source node or an intermediate node stores packets in buffer and carries them while it moves around. These packets are forwarded to other nodes based on predefined criteria and finally are delivered to a destination node via multiple hops. In this paper, we improve the dissemination speed of PRoPHET (probability routing protocol using history of encounters and transitivity) protocol by employing epidemic protocol for disseminating message m, if forwarding counter and hop counter values are smaller than or equal to the threshold values. The performance of the proposed protocol was analyzed from the aspect of delivery probability, average delay, and overhead ratio. Numerical results show that the proposed protocol can improve the delivery probability, average delay, and overhead ratio of PRoPHET protocol by appropriately selecting the threshold forwarding counter and threshold hop counter values.

  14. Detailed noise measurements on the SR-7A propeller: Tone behavior with helical tip Mach number

    NASA Technical Reports Server (NTRS)

    Dittmar, James H.; Hall, David G.

    1991-01-01

    Detailed noise measurements were taken on the SR-7A propeller to investigate the behavior of the noise with helical tip Mach number and then to level off as Mach number was increased further. This behavior was further investigated by obtaining detailed pressure-time histories of data. The pressure-time histories indicate that a portion of the primary pressure pulse is progressively cancelled by a secondary pulse which results in the noise leveling off as the helical tip Mach number is increased. This second pulse appears to originate on the same blade as the primary pulse and is in some way connected to the blade itself. This leaves open the possibility of redesigning the blade to improve the cancellation; thereby, the propeller noise is reduced.

  15. Controlled modulation of hard and soft X-ray induced tunneling currents utilizing coaxial metal-insulator-metal probe tips

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cummings, Marvin; Shirato, Nozomi; Kersell, Heath

    Here, the effect of a local external electric field on the barrier potential of a tunneling gap is studied utilizing an emerging technique, synchrotron x-ray scanning tunneling microscopy. Here, we demonstrate that the shape of the potential barrier in the tunneling gap can be altered by a localized external electric field, generated by voltages placed on the metallic outer shield of a nanofabricated coaxial metal-insulator-metal tip, resulting in a controlled linear modulation of the tunneling current. Experiments at hard and soft x-ray synchrotron beamlines reveal that both the chemical contrast and magnetic contrast signals measured by the tip can bemore » drastically enhanced, resulting in improved local detection of chemistry and magnetization at the surface.« less

  16. Controlled modulation of hard and soft X-ray induced tunneling currents utilizing coaxial metal-insulator-metal probe tips

    DOE PAGES

    Cummings, Marvin; Shirato, Nozomi; Kersell, Heath; ...

    2017-01-05

    Here, the effect of a local external electric field on the barrier potential of a tunneling gap is studied utilizing an emerging technique, synchrotron x-ray scanning tunneling microscopy. Here, we demonstrate that the shape of the potential barrier in the tunneling gap can be altered by a localized external electric field, generated by voltages placed on the metallic outer shield of a nanofabricated coaxial metal-insulator-metal tip, resulting in a controlled linear modulation of the tunneling current. Experiments at hard and soft x-ray synchrotron beamlines reveal that both the chemical contrast and magnetic contrast signals measured by the tip can bemore » drastically enhanced, resulting in improved local detection of chemistry and magnetization at the surface.« less

  17. Detailed noise measurements on the SR-7A propeller: Tone behavior with helical tip Mach number

    NASA Astrophysics Data System (ADS)

    Dittmar, James H.; Hall, David G.

    1991-12-01

    Detailed noise measurements were taken on the SR-7A propeller to investigate the behavior of the noise with helical tip Mach number and then to level off as Mach number was increased further. This behavior was further investigated by obtaining detailed pressure-time histories of data. The pressure-time histories indicate that a portion of the primary pressure pulse is progressively cancelled by a secondary pulse which results in the noise leveling off as the helical tip Mach number is increased. This second pulse appears to originate on the same blade as the primary pulse and is in some way connected to the blade itself. This leaves open the possibility of redesigning the blade to improve the cancellation; thereby, the propeller noise is reduced.

  18. Twenty-five years after the first TIPS in Spain.

    PubMed

    Bilbao Jaureguízar, J I

    2016-01-01

    The incorporation, 25 years ago, of transjugular intrahepatic portosystemic shunting, better known by the acronym TIPS, represents an indisputable improvement in the treatment and management of patients with symptoms due to portal hypertension. This article discusses the origins of the technique and the technical innovations that have been progressively added through the years. The implantation of coated stents, which protect the stent from processes in the parenchymal track that can lead to stenosis, have helped ensure long-term patency, thus reducing the need for reintervention. Solid evidence from valuable publications has situated TIPS at the forefront of the treatment options in a wide variety of clinical situations associated with portal hypertension. Copyright © 2016 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  19. Method and system for near-field spectroscopy using targeted deposition of nanoparticles

    NASA Technical Reports Server (NTRS)

    Anderson, Mark S. (Inventor)

    2012-01-01

    There is provided in one embodiment of the invention a method for analyzing a sample material using surface enhanced spectroscopy. The method comprises the steps of imaging the sample material with an atomic force microscope (AFM) to select an area of interest for analysis, depositing nanoparticles onto the area of interest with an AFM tip, illuminating the deposited nanoparticles with a spectrometer excitation beam, and disengaging the AFM tip and acquiring a localized surface enhanced spectrum. The method may further comprise the step of using the AFM tip to modulate the spectrometer excitation beam above the deposited nanoparticles to obtain improved sensitivity data and higher spatial resolution data from the sample material. The invention further comprises in one embodiment a system for analyzing a sample material using surface enhanced spectroscopy.

  20. Sensor tip for a robotic gripper and method of manufacture

    NASA Technical Reports Server (NTRS)

    Lorenz, Robert D. (Inventor); Jackson, Gregory T. (Inventor)

    1991-01-01

    A sensor tip (10) for use in a robotic hand has a three-dimensional compliant elastomeric body (12) with an outer boundary (22) having a circular base (24) and a convex surface (26) extending therefrom. Four strain transducers (14, 16, 18, and 20) produce electrical signals indicative of the strain at various positions near the boundary of the elastomeric body (12) resulting from forces exerted upon the sensor tip (10) by an object which the robotic hand is manipulating. The transducers (14, 16, 18, and 20) are positioned about the convex surface (26) so as to produce signals that may be decoupled to determine the normal and tangential forces and the applied torque. A buffer amplifier circuit (34), one for each of the transducers (14, 16, 18, and 20), receives the signals and provides quasi-steady state force information. The circuit (34) connects the respective transducer (40) in a feedback loop around an amplifier (36) and has desirable attributes for static charge buffering. The sensor tip (10) is calibrated to determine proportionality constants for the decoupling algorithm for use of a force delivering system (60), which uses voice coils (74) to apply a force that is linearly related to the current introduced to each of the coils (74). A method of manufacture of the sensor tip (10) results in improved bonding between the transducers (14, 16, 18, and 20) and the elastomeric body (12) for better performance and longer life of the sensor tip (10).

  1. Sensor tip for a robotic gripper and method of manufacture

    NASA Technical Reports Server (NTRS)

    Lorenz, Robert D. (Inventor); Jackson, Gregory T. (Inventor)

    1993-01-01

    A sensor tip (10) for use in a robotic hand has a three-dimensional compliant elastomeric body (12) with an outer boundary (22) having a circular base (24) and a convex surface (26) extending therefrom. Four strain transducers (14, 16, 18, and 20) produce electrical signals indicative of the strain at various positions near the boundary of the elastomeric body (12) resulting from forces exerted upon the sensor tip (10) by an object which the robotic hand is manipulating. The transducers (14, 16, 18, and 20) are positioned about the convex surface (26) so as to produce signals that may be decoupled to determine the normal and tangential forces and the applied torque. A buffer amplifier circuit (34), one for each of the transducers (14, 16, 18, and 20), receives the signals and provides quasi-steady state force information. The circuit (34) connects the respective transducer (40) in a feedback loop around an amplifier (36) and has desirable attributes for static charge buffering. The sensor tip (10) is calibrated to determine proportionality constants for the decoupling algorithm for use of a force delivering system (60), which uses voice coils (74) to apply a force that is linearly related to the current introduced to each of the coils (74). A method of manufacture of the sensor tip (10) results in improved bonding between the transducers (14, 16, 18, and 20) and the elastomeric body (12) for better performance and longer life of the sensor tip (10).

  2. Modified Direct-Type Septal Extension Grafts: Their Stability and Usefulness in Asian Rhinoplasty.

    PubMed

    Han, So-Eun; Han, Kihwan; Choi, Jaehoon; Yun, Tae Bin

    2017-03-01

    In Asian rhinoplasty, many autogenous cartilage grafts are required for correction of the nasal tip and columella, but the amount has limitations. A modified direct-type septal extension graft, in continuity with the entire caudal border of the septal cartilage with an edge-to-edge coaptation, can effectively and concomitantly correct the nasal tip and columella deformities using a limited amount of septal cartilage graft. The purpose of this study was to evaluate long-term cosmetic outcomes and stability from the modified direct extension grafts. Fifty-seven patients with a follow-up of more than 1 year were enrolled in the study. A total of 11 measurement items were evaluated from basal and right lateral views by photogrammetry using standardized clinical photographic techniques. The overall mean follow-up period was 20.4 months. When comparing the preoperative and postoperative values, the nasal tip projection, nasal bridge length, nasal tip angle, height of nose, and the columellar labial angle increased significantly; additionally, the soft nose width index, width between ac-ac index, nostril axis inclination, columellar length (Rt-Lt), and the alar length (Rt-Lt) decreased significantly. No resorption, buckling, or displacement of the graft was observed during the follow-up period. The modified direct extension graft demonstrated a marked aesthetic improvement in the nasal tip and columella, and it provided long-term stability. Therefore, the modified direct extension graft is useful for correction of the nasal tip and columella in Asian rhinoplasty.

  3. Field ion source development for neutron generators

    NASA Astrophysics Data System (ADS)

    Bargsten Johnson, B.; Schwoebel, P. R.; Holland, C. E.; Resnick, P. J.; Hertz, K. L.; Chichester, D. L.

    2012-01-01

    An ion source based on the principles of electrostatic field desorption is being developed to improve the performance of existing compact neutron generators. The ion source is an array of gated metal tips derived from field electron emitter array microfabrication technology. A comprehensive summary of development and experimental activities is presented. Many structural modifications to the arrays have been incorporated to achieve higher tip operating fields, while lowering fields at the gate electrode to prevent gate field electron emission which initiates electrical breakdown in the array. The latest focus of fabrication activities has been on rounding the gate electrode edge and surrounding the gate electrode with dielectric material. Array testing results have indicated a steady progression of increased array tip operating fields with each new design tested. The latest arrays have consistently achieved fields beyond those required for the onset of deuterium desorption (˜20 V/nm), and have demonstrated the desorption of deuterium at fields up to 36 V/nm. The number of ions desorbed from an array has been quantified, and field desorption of metal tip substrate material from array tips has been observed for the first time. Gas-phase field ionization studies with ˜10,000 tip arrays have achieved deuterium ion currents of ˜50 nA. Neutron production by field ionization has yielded ˜10 2 n/s from ˜1 mm 2 of array area using the deuterium-deuterium fusion reaction at 90 kV.

  4. The SERS and TERS effects obtained by gold droplets on top of Si nanowires.

    PubMed

    Becker, M; Sivakov, V; Andrä, G; Geiger, R; Schreiber, J; Hoffmann, S; Michler, J; Milenin, A P; Werner, P; Christiansen, S H

    2007-01-01

    We show that hemispherical gold droplets on top of silicon nanowires when grown by the vapor-liquid-solid (VLS) mechanism, can produce a significant enhancement of Raman scattered signals. Signal enhancement for a few or even just single gold droplets is demonstrated by analyzing the enhanced Raman signature of malachite green molecules. For this experiment, trenches (approximately 800 nm wide) were etched in a silicon-on-insulator (SOI) wafer along <110> crystallographic directions that constitute sidewalls ({110} surfaces) suitable for the growth of silicon nanowires in <111> directions with the intention that the gold droplets on the silicon nanowires can meet somewhere in the trench when growth time is carefully selected. Another way to realize gold nanostructures in close vicinity is to attach a silicon nanowire with a gold droplet onto an atomic force microscopy (AFM) tip and to bring this tip toward another gold-coated AFM tip where malachite green molecules were deposited prior to the measurements. In both experiments, signal enhancement of characteristic Raman bands of malachite green molecules was observed. This indicates that silicon nanowires with gold droplets atop can act as efficient probes for tip-enhanced Raman spectroscopy (TERS). In our article, we show that a nanowire TERS probe can be fabricated by welding nanowires with gold droplets to AFM tips in a scanning electron microscope (SEM). TERS tips made from nanowires could improve the spatial resolution of Raman spectroscopy so that measurements on the nanometer scale are possible.

  5. State Fiscal Years 1997-2000 Transportation Improvement Program for Green, Miami and Montgomery Counties, Ohio - June 1996

    DOT National Transportation Integrated Search

    1996-06-01

    The Transportation Improvement Program, often referred to as the TIP, is a four-year implementation schedule for transportation projects within the Greene, Miami and Montgomery County Region. The locally developed State Fiscal Year 1997 through Fisca...

  6. School Solutions. Special Report: IAQ and Energy.

    ERIC Educational Resources Information Center

    Birr, Dave

    1999-01-01

    Discusses how energy service companies (ESCO) can help schools upgrade their indoor air quality and make them environmentally sound. How ESCO's help in arranging funding for indoor environmental improvements through energy performance contracts is discussed. Tips on energy-efficiency measures for improving indoor environmental quality are…

  7. Wood-Washington-Wirt Interstate Planning Commission : transportation improvement program, FY 1997-2000

    DOT National Transportation Integrated Search

    2001-01-01

    The Transportation Improvement Program, or TIP, required under the provisions of Title 23, U. S. C., and the Federal Transit Act, as amended through June 1992, includes projects consistent with the Long Range Transportation Plan for the study area. T...

  8. NASA Trapezoidal Wing Computations Including Transition and Advanced Turbulence Modeling

    NASA Technical Reports Server (NTRS)

    Rumsey, C. L.; Lee-Rausch, E. M.

    2012-01-01

    Flow about the NASA Trapezoidal Wing is computed with several turbulence models by using grids from the first High Lift Prediction Workshop in an effort to advance understanding of computational fluid dynamics modeling for this type of flowfield. Transition is accounted for in many of the computations. In particular, a recently-developed 4-equation transition model is utilized and works well overall. Accounting for transition tends to increase lift and decrease moment, which improves the agreement with experiment. Upper surface flap separation is reduced, and agreement with experimental surface pressures and velocity profiles is improved. The predicted shape of wakes from upstream elements is strongly influenced by grid resolution in regions above the main and flap elements. Turbulence model enhancements to account for rotation and curvature have the general effect of increasing lift and improving the resolution of the wing tip vortex as it convects downstream. However, none of the models improve the prediction of surface pressures near the wing tip, where more grid resolution is needed.

  9. A method for improving the light intensity distribution in dental light-curing units.

    PubMed

    Arikawa, Hiroyuki; Takahashi, Hideo; Minesaki, Yoshito; Muraguchi, Kouichi; Matsuyama, Takashi; Kanie, Takahito; Ban, Seiji

    2011-01-01

    A method for improving the uniformity of the radiation light from dental light-curing units (LCUs), and the effect on the polymerization of light-activated composite resin are investigated. Quartz-tungsten halogen, plasma-arc, and light-emitting diode LCUs were used, and additional optical elements such as a mixing tube and diffusing screen were employed to reduce the inhomogeneity of the radiation light. The distribution of the light intensity from the light guide tip was measured across the guide tip, as well as the distribution of the surface hardness of the light-activated resin emitted with the LCUs. Although the additional optical elements caused 13.2-25.9% attenuation of the light intensity, the uniformity of the light intensity of the LCUs was significantly improved in the modified LCUs, and the uniformity of the surface hardness of the resin was also improved. Our results indicate that the addition of optical elements to the LCU may be a simple and effective method for reducing inhomogeneity in radiation light from the LCUs.

  10. Inpatient Cost Assessment of Transjugular Intrahepatic Portosystemic Shunt in the USA from 2001 to 2012.

    PubMed

    Kuei, Andrew; Lee, Edward Wolfgang; Saab, Sammy; Busuttil, Ronald W; Durazo, Francisco; Han, Steven-Huy; ElKabany, Mohamed; McWilliams, Justin P; Kee, Stephen T

    2016-10-01

    Despite widespread use of transjugular intrahepatic portosystemic shunt (TIPS) for treatment of portal hypertension, a paucity of nationwide data exists on predictors of the economic impact related to TIPS. Using the National Inpatient Sample (NIS) database from 2001 to 2012, we aimed to evaluate factors contributing to hospital cost of patients admitted to US hospitals for TIPS. Using the NIS, we identified a discharge-weighted national estimate of 61,004 TIPS procedures from 2001 to 2012. Through independent sample analysis, we determined profile factors related to increases in hospital costs. Of all TIPS cases, the mean charge adjusted for inflation to the year 2012 is $125,044 ± $160,115. The mean hospital cost adjusted for inflation is $44,901 ± $54,565. Comparing pre- and post-2005, mean charges and cost have increased considerably ($98,154 vs. $142,652, p < 0.001 and $41,656 vs. $46,453, p < 0.001, respectively). Patients transferred from a different hospital, weekend admissions, Asian/Pacific Islander patients, and hospitals in the Northeastern and Western region had higher cost. Number of diagnoses and number of procedures show positive correlations with hospital cost, with number of procedures exhibiting stronger relationships (Pearson 0.613). Comorbidity measures with highest increases in cost were pulmonary circulation disorders ($32,157 increase, p < 0.001). The cost of the TIPS procedure is gradually rising for hospitals. Alongside recent healthcare reform through the Affordable Care Act, measures to reduce the economic burden of TIPS are of increasing importance. Data from this study are intended to aid physicians and hospitals in identifying improvements that could reduce hospital costs.

  11. Modeling and estimation of tip contact force for steerable ablation catheters.

    PubMed

    Khoshnam, Mahta; Skanes, Allan C; Patel, Rajni V

    2015-05-01

    The efficacy of catheter-based cardiac ablation procedures can be significantly improved if real-time information is available concerning contact forces between the catheter tip and cardiac tissue. However, the widely used ablation catheters are not equipped for force sensing. This paper proposes a technique for estimating the contact forces without direct force measurements by studying the changes in the shape of the deflectable distal section of a conventional 7-Fr catheter (henceforth called the "deflectable distal shaft," the "deflectable shaft," or the "shaft" of the catheter) in different loading situations. First, the shaft curvature when the tip is moving in free space is studied and based on that, a kinematic model for the deflectable shaft in free space is proposed. In the next step, the shaft shape is analyzed in the case where the tip is in contact with the environment, and it is shown that the curvature of the deflectable shaft provides useful information about the loading status of the catheter and can be used to define an index for determining the range of contact forces exerted by the ablation tip. Experiments with two different steerable ablation catheters show that the defined index can detect the range of applied contact forces correctly in more than 80% of the cases. Based on the proposed technique, a framework for obtaining contact force information by using the shaft curvature at a limited number of points along the deflectable shaft is constructed. The proposed kinematic model and the force estimation technique can be implemented together to describe the catheter's behavior before contact, detect tip/tissue contact, and determine the range of contact forces. This study proves that the flexibility of the catheter's distal shaft provides a means of estimating the force exerted on tissue by the ablation tip.

  12. Factors Influencing Intracavitary Electrocardiographic P-Wave Changes during Central Venous Catheter Placement

    PubMed Central

    Wang, Guorong; Guo, Ling; Jiang, Bin; Huang, Min; Zhang, Jian; Qin, Ying

    2015-01-01

    Amplitude changes in the P-wave of intracavitary electrocardiography have been used to assess the tip placement of central venous catheters. The research assessed the sensitivity and specificity of this sign in comparison with standard radiographic techniques for tip location, focusing on factors influencing its clinical utility. Both intracavitary electrocardiography guided tip location and X-ray positioning were used to verify catheter tip locations in patients undergoing central venous catheter insertion. Intracavitary electrocardiograms from 1119 patients (of a total 1160 subjects) showed specific amplitude changes in the P-wave. As the results show, compared with X-ray positioning, the sensitivity of electrocardiography-guided tip location was 97.3%, with false negative rate of 2.7%; the specificity was 1, with false positive rate of zero. Univariate analyses indicated that features including age, gender, height, body weight, and heart rate have no statistically significant influence on P-wave amplitude changes (P>0.05). Multivariate logistic regression revealed that catheter insertion routes (OR = 2.280, P = 0.003) and basal P-wave amplitude (OR = 0.553, P = 0.003) have statistically significant impacts on P-wave amplitude changes. As a reliable indicator of tip location, amplitude change in the P-wave has proved of good sensitivity and excellent specificity, and the minor, zero, false positive rate supports the clinical utility of this technique in early recognition of malpositioned tips. A better sensitivity was achieved in placement of centrally inserted central catheters (CICCs) than that of peripherally inserted central catheters (PICCs). In clinical practice, a combination of intracavitary electrocardiography, ultrasonic inspection and the anthropometric measurement method would further improve the accuracy. PMID:25915758

  13. Potential testing of reprocessing procedures by real-time polymerase chain reaction: A multicenter study of colonoscopy devices.

    PubMed

    Valeriani, Federica; Agodi, Antonella; Casini, Beatrice; Cristina, Maria Luisa; D'Errico, Marcello Mario; Gianfranceschi, Gianluca; Liguori, Giorgio; Liguori, Renato; Mucci, Nicolina; Mura, Ida; Pasquarella, Cesira; Piana, Andrea; Sotgiu, Giovanni; Privitera, Gaetano; Protano, Carmela; Quattrocchi, Annalisa; Ripabelli, Giancarlo; Rossini, Angelo; Spagnolo, Anna Maria; Tamburro, Manuela; Tardivo, Stefano; Veronesi, Licia; Vitali, Matteo; Romano Spica, Vincenzo

    2018-02-01

    Reprocessing of endoscopes is key to preventing cross-infection after colonoscopy. Culture-based methods are recommended for monitoring, but alternative and rapid approaches are needed to improve surveillance and reduce turnover times. A molecular strategy based on detection of residual traces from gut microbiota was developed and tested using a multicenter survey. A simplified sampling and DNA extraction protocol using nylon-tipped flocked swabs was optimized. A multiplex real-time polymerase chain reaction (PCR) test was developed that targeted 6 bacteria genes that were amplified in 3 mixes. The method was validated by interlaboratory tests involving 5 reference laboratories. Colonoscopy devices (n = 111) were sampled in 10 Italian hospitals. Culture-based microbiology and metagenomic tests were performed to verify PCR data. The sampling method was easily applied in all 10 endoscopy units and the optimized DNA extraction and amplification protocol was successfully performed by all of the involved laboratories. This PCR-based method allowed identification of both contaminated (n = 59) and fully reprocessed endoscopes (n = 52) with high sensibility (98%) and specificity (98%), within 3-4 hours, in contrast to the 24-72 hours needed for a classic microbiology test. Results were confirmed by next-generation sequencing and classic microbiology. A novel approach for monitoring reprocessing of colonoscopy devices was developed and successfully applied in a multicenter survey. The general principle of tracing biological fluids through microflora DNA amplification was successfully applied and may represent a promising approach for hospital hygiene. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  14. Endovascular Management of Refractory Hepatic Encephalopathy Complication of Transjugular Intrahepatic Portosystemic Shunt (TIPS): Comprehensive Review and Clinical Practice Algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pereira, Keith, E-mail: keithjppereira@gmail.com; Carrion, Andres F., E-mail: andres.carrionmonsa@jhsmiami.org; Salsamendi, Jason, E-mail: JSalsamendi@med.miami.edu

    Transjugular intrahepatic portosystemic shunt (TIPS) has evolved as an effective intervention for treatment of complications of portal hypertension. The use of polytetrafluoroethylene-covered stents have improved the patency of the shunts and diminished the incidence of TIPS dysfunction. However, TIPS-related refractory hepatic encephalopathy (rHE) poses a significant challenge. Approximately 3–7 % of patients with TIPS develop rHE. Refractory hepatic encephalopathy is defined as a recurrent or persistent encephalopathy despite appropriate medical treatment. Hepatic encephalopathy can be an extremely debilitating complication that profoundly affects quality of life. The approach to management of patients with rHE is complex and typically requires collaboration between differentmore » specialties. Liver transplantation is the ultimate treatment for rHE; however, the ongoing shortage of organ donation markedly limits this treatment option. Alternative therapies such as shunt occlusion or reduction can control symptoms and serve as a ‘bridge’ therapy to liver transplantation. Therefore, interventional radiologists play a key role in the management of these patients by offering a variety of endovascular techniques. The purpose of this review is to highlight some of these endovascular techniques and to develop a therapeutic algorithm that can be applied in clinical practice for the management of rHE.« less

  15. Optical detection of ultrasound using an apertureless near-field scanning optical microscopy system

    NASA Astrophysics Data System (ADS)

    Ahn, Phillip; Zhang, Zhen; Sun, Cheng; Balogun, Oluwaseyi

    2013-01-01

    Laser ultrasonics techniques are power approaches for non-contact generation and detection of high frequency ultrasound on a local scale. In these techniques, optical diffraction limits the spatial information that can be accessed from a measurement. In order to improve the lateral spatial resolution, we incorporate an apertureless near-field scanning optical microscope (aNSOM) into laser ultrasonics setup for local detection of laser generated ultrasound. The aNSOM technique relies on the measurement of a weak backscattered near-field light intensity resulting from the oblique illumination of a nanoscale probe-tip positioned close to a sample surface. We enhance the optical near-field intensity by coupling light to surface plasmon polaritons (SPPs) on the shaft of an atomic force microscopy (AFM) cantilever. The SPPs propagate down the AFM shaft, localize at the tip apex, and are backscattered to the far-field when the separation distance between the probe tip and the sample surface is comparable to the probe-tip radius. The backscattered near-field intensity is dynamically modulated when an ultrasonic wave arrives at the sample surface leading to a transient change in the tip-sample separation distance. We present experimental results detailing measurement of broadband and narrowband laser generated ultrasound in solids with frequencies reaching up to 180 MHz range.

  16. Improved Patency of Transjugular Intrahepatic Portosystemic Shunt: The Efficacy of Cilostazol for the Prevention of Pseudointimal Hyperplasia in Swine TIPS Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Sang Woo; Cha, In Ho; Kim, Chul Hwan

    Purpose. To investigate the efficacy of oral administration of cilostazol to inhibit pseudointimal/intimal hyperplasia in swine TIPS models. Methods. Successful TIPS creation was carried out in 11 of 12 healthy young pigs (20-25 kg). In the treatment group (n = 6), both cilostazol and aspirin were administered daily, from the first day of TIPS creation. The control group (n = 5) was administered only aspirin. The animals were followed-up for 2 weeks and then killed. The specimen (including portal vein, hepatic parenchymal tract, hepatic vein, and inferior vena cava) and stents were carefully bisected in a longitudinal fashion. The controlmore » group was compared with the treatment group by means of a gross and histologic evaluation of the degree of pseudointimal/intimal hyperplasia in the shunt. Results. At the gross evaluation, the control group showed considerably more pseudointimal/intimal hyperplasia than the treatment group. Using microscopic evaluation, there was a statistically significant difference (p < 0.05) in the mean maximum pseudointimal/intimal hyperplasia thickness between the control group (2.97 {+-} 0.33 mm) and treatment group (0.73 {+-} 0.27 mm). Conclusion. Oral administration of cilostazol may have been effective in reducing pseudointimal/intimal hyperplasia in swine TIPS models.« less

  17. Efficiency arcjet thruster with controlled arc startup and steady state attachment

    NASA Technical Reports Server (NTRS)

    Smith, William W. (Inventor); Knowles, Steven C. (Inventor)

    1989-01-01

    An improved efficiency arcjet thruster has a constrictor and electrically-conductive nozzle anode defining an arc chamber, and an electrically-conductive rod having a tip spaced upstream from the constrictor and defining a cathode spaced from the anode by a gap generally coextensive with the arc chamber. An electrical potential is applied to the anode and cathode to generate an electrical arc in the arc chamber from the cathode to anode. Catalytically decomposed hydrazine is supplied to the arc chamber with generation of the arc so as to produce thermal heating and expansion thereof through the nozzle. The constrictor can have a electrically insulative portion disposed between the cathode tip and the nozzle anode, and an electrically-conductive anode extension disposed along the insulative portion so as to define an auxiliary gap with the cathode tip substantially smaller than the gap defined between the cathode and nozzle anode for facilitating startup of arc generation. The constrictor can also include an electrically-conductive electrode with a variable electrical potential to vary the shape of the arc generated in the arc chamber. Also, the cathode is mounted for axial movement such that the gap between its tip and the nozzle anode can be varied to facilitate a generally nonerosive generation of the electrical arc at startup and reliable steady state operation. Further, the arc chamber can have a nonparallel subsonic-to-supersonic transition configuration, or alternatively solely a nonparallel supersonic configuration, for improved arc attachment.

  18. Torsional tapping atomic force microscopy for molecular resolution imaging of soft matter

    NASA Astrophysics Data System (ADS)

    Hobbs, Jamie; Mullin, Nic

    2012-02-01

    Despite considerable advances in image resolution on challenging, soft systems, a method for obtaining molecular resolution on `real' samples with significant surface roughness has remained elusive. Here we will show that a relatively new technique, torsional tapping AFM (TTAFM), is capable of imaging with resolution down to 3.7 Angrstrom on the surface of `bulk' polymer films [1]. In TTAFM T-shaped cantilevers are driven into torsional oscillation. As the tip is offset from the rotation axis this provides a tapping motion. Due to the high frequency and Q of the oscillation and relatively small increase in spring constant, improved cantilever dynamics and force sensitivity are obtained. As the tip offset from the torsional axis is relatively small (typically 25 microns), the optical lever sensitivity is considerably improved compared to flexural oscillation. Combined these give a reduction in noise floor by a factor of 12 just by changing the cantilever geometry. The ensuing low noise allows the use of ultra-sharp `whisker' tips with minimal blunting. As the cantilevers remain soft in the flexural axis, the force when imaging with error is also reduced, further protecting the tip. We will show that this combination allows routine imaging of the molecular structure of semicrystalline polymer films, including chain folds, loose loops and tie-chains in polyethylene, and the helical conformation of polypropylene within the crystal, using a standard, commercial AFM. [4pt] [1] N Mullin, JK Hobbs, PRL 107, 197801 (2011)

  19. SELF ALIGNED TIP DEINSULATION OF ATOMIC LAYER DEPOSITED AL2O3 AND PARYLENE C COATED UTAH ELECTRODE ARRAY BASED NEURAL INTERFACES

    PubMed Central

    Xie, Xianzong; Rieth, Loren; Negi, Sandeep; Bhandari, Rajmohan; Caldwell, Ryan; Sharma, Rohit; Tathireddy, Prashant; Solzbacher, Florian

    2014-01-01

    The recently developed alumina and Parylene C bi-layer encapsulation improved the lifetime of neural interfaces. Tip deinsulation of Utah electrode array based neural interfaces is challenging due to the complex 3D geometries and high aspect ratios of the devices. A three-step self-aligned process was developed for tip deinsulation of bilayer encapsulated arrays. The deinsulation process utilizes laser ablation to remove Parylene C, O2 reactive ion etching to remove carbon and Parylene residues, and buffered oxide etch to remove alumina deposited by atomic layer deposition, and expose the IrOx tip metallization. The deinsulated iridium oxide area was characterized by scanning electron microscopy, atomic force microscopy, X-ray photoelectron spectroscopy, and electrochemical impedance spectroscopy to determine the morphology, surface morphology, composition, and electrical properties of the deposited layers and deinsulated tips. The alumina layer was found to prevent the formation of micro cracks on iridium oxide during the laser ablation process, which has been previously reported as a challenge for laser deinsulation of Parylene films. The charge injection capacity, charge storage capacity, and impedance of deinsulated iridium oxide were characterized to determine the deinsulation efficacy compared to Parylene-only insulation. Deinsulated iridium oxide with bilayer encapsulation had higher charge injection capacity (240 vs 320 nC) and similar electrochemical impedance (2.5 vs 2.5 kΩ) compared to deinsulated iridium oxide with only Parylene coating for an area of 2 × 10−4 cm2. Tip impedances were in the ranges of 20 to 50 kΩ, with median of 32 KΩ and standard deviation of 30 kΩ, showing the effectiveness of the self-aligned deinsulation process for alumina and Parylene C bi-layer encapsulation. The relatively uniform tip impedance values demonstrated the consistency of tip exposures. PMID:24771981

  20. Small diameter carbon nanopipettes

    NASA Astrophysics Data System (ADS)

    Singhal, Riju; Bhattacharyya, Sayan; Orynbayeva, Zulfiya; Vitol, Elina; Friedman, Gary; Gogotsi, Yury

    2010-01-01

    Nanoscale multifunctional carbon probes facilitate cellular studies due to their small size, which makes it possible to interrogate organelles within living cells in a minimally invasive fashion. However, connecting nanotubes to macroscopic devices and constructing an integrated system for the purpose of fluid and electrical signal transfer is challenging, as is often the case with nanoscale components. We describe a non-catalytic chemical vapor deposition based method for batch fabrication of integrated multifunctional carbon nanopipettes (CNPs) with tip diameters much smaller (10-30 nm) than previously reported (200 nm and above) and approaching those observed for multiwalled carbon nanotubes. This eliminates the need for complicated attachment/assembly of nanotubes into nanofluidic devices. Variable tip geometries and structures were obtained by controlled deposition of carbon inside and outside quartz pipettes. We have shown that the capillary length and gas flow rate have a marked effect on the carbon deposition. This gives us a flexible protocol, useful for growing carbon layers of different thicknesses at selective locations on a glass pipette to yield a large variety of cellular probes in bulk quantities. The CNPs possess an open channel for fluid transfer with the carbon deposited inside at 875 °C behaving like an amorphous semiconductor. Vacuum annealing of the CNP tips at temperatures up to 2000 °C yields graphitic carbon structures with an increase in conductivity of two orders of magnitude. Penetration of the integrated carbon nanoprobes into cells was shown to produce minimal Ca2+ signals, fast recovery of basal Ca2+ levels and no adverse activation of the cellular metabolism during interrogation times as long as 0.5-1 h.

  1. Small diameter carbon nanopipettes.

    PubMed

    Singhal, Riju; Bhattacharyya, Sayan; Orynbayeva, Zulfiya; Vitol, Elina; Friedman, Gary; Gogotsi, Yury

    2010-01-08

    Nanoscale multifunctional carbon probes facilitate cellular studies due to their small size, which makes it possible to interrogate organelles within living cells in a minimally invasive fashion. However, connecting nanotubes to macroscopic devices and constructing an integrated system for the purpose of fluid and electrical signal transfer is challenging, as is often the case with nanoscale components. We describe a non-catalytic chemical vapor deposition based method for batch fabrication of integrated multifunctional carbon nanopipettes (CNPs) with tip diameters much smaller (10-30 nm) than previously reported (200 nm and above) and approaching those observed for multiwalled carbon nanotubes. This eliminates the need for complicated attachment/assembly of nanotubes into nanofluidic devices. Variable tip geometries and structures were obtained by controlled deposition of carbon inside and outside quartz pipettes. We have shown that the capillary length and gas flow rate have a marked effect on the carbon deposition. This gives us a flexible protocol, useful for growing carbon layers of different thicknesses at selective locations on a glass pipette to yield a large variety of cellular probes in bulk quantities. The CNPs possess an open channel for fluid transfer with the carbon deposited inside at 875 degrees C behaving like an amorphous semiconductor. Vacuum annealing of the CNP tips at temperatures up to 2000 degrees C yields graphitic carbon structures with an increase in conductivity of two orders of magnitude. Penetration of the integrated carbon nanoprobes into cells was shown to produce minimal Ca(2+) signals, fast recovery of basal Ca(2+) levels and no adverse activation of the cellular metabolism during interrogation times as long as 0.5-1 h.

  2. Eliciting improved quantitative judgements using the IDEA protocol: A case study in natural resource management.

    PubMed

    Hemming, Victoria; Walshe, Terry V; Hanea, Anca M; Fidler, Fiona; Burgman, Mark A

    2018-01-01

    Natural resource management uses expert judgement to estimate facts that inform important decisions. Unfortunately, expert judgement is often derived by informal and largely untested protocols, despite evidence that the quality of judgements can be improved with structured approaches. We attribute the lack of uptake of structured protocols to the dearth of illustrative examples that demonstrate how they can be applied within pressing time and resource constraints, while also improving judgements. In this paper, we demonstrate how the IDEA protocol for structured expert elicitation may be deployed to overcome operational challenges while improving the quality of judgements. The protocol was applied to the estimation of 14 future abiotic and biotic events on the Great Barrier Reef, Australia. Seventy-six participants with varying levels of expertise related to the Great Barrier Reef were recruited and allocated randomly to eight groups. Each participant provided their judgements using the four-step question format of the IDEA protocol ('Investigate', 'Discuss', 'Estimate', 'Aggregate') through remote elicitation. When the events were realised, the participant judgements were scored in terms of accuracy, calibration and informativeness. The results demonstrate that the IDEA protocol provides a practical, cost-effective, and repeatable approach to the elicitation of quantitative estimates and uncertainty via remote elicitation. We emphasise that i) the aggregation of diverse individual judgements into pooled group judgments almost always outperformed individuals, and ii) use of a modified Delphi approach helped to remove linguistic ambiguity, and further improved individual and group judgements. Importantly, the protocol encourages review, critical appraisal and replication, each of which is required if judgements are to be used in place of data in a scientific context. The results add to the growing body of literature that demonstrates the merit of using structured elicitation protocols. We urge decision-makers and analysts to use insights and examples to improve the evidence base of expert judgement in natural resource management.

  3. CT and MR Protocol Standardization Across a Large Health System: Providing a Consistent Radiologist, Patient, and Referring Provider Experience.

    PubMed

    Sachs, Peter B; Hunt, Kelly; Mansoubi, Fabien; Borgstede, James

    2017-02-01

    Building and maintaining a comprehensive yet simple set of standardized protocols for a cross-sectional image can be a daunting task. A single department may have difficulty preventing "protocol creep," which almost inevitably occurs when an organized "playbook" of protocols does not exist and individual radiologists and technologists alter protocols at will and on a case-by-case basis. When multiple departments or groups function in a large health system, the lack of uniformity of protocols can increase exponentially. In 2012, the University of Colorado Hospital formed a large health system (UCHealth) and became a 5-hospital provider network. CT and MR imaging studies are conducted at multiple locations by different radiology groups. To facilitate consistency in ordering, acquisition, and appearance of a given study, regardless of location, we minimized the number of protocols across all scanners and sites of practice with a clinical indication-driven protocol selection and standardization process. Here we review the steps utilized to perform this process improvement task and insure its stability over time. Actions included creation of a standardized protocol template, which allowed for changes in electronic storage and management of protocols, designing a change request form, and formation of a governance structure. We utilized rapid improvement events (1 day for CT, 2 days for MR) and reduced 248 CT protocols into 97 standardized protocols and 168 MR protocols to 66. Additional steps are underway to further standardize output and reporting of imaging interpretation. This will result in an improved, consistent radiologist, patient, and provider experience across the system.

  4. Security of the arbitrated quantum signature protocols revisited

    NASA Astrophysics Data System (ADS)

    Kejia, Zhang; Dan, Li; Qi, Su

    2014-01-01

    Recently, much attention has been paid to the study of arbitrated quantum signature (AQS). Among these studies, the cryptanalysis of some AQS protocols and a series of improved ideas have been proposed. Compared with the previous analysis, we present a security criterion, which can judge whether an AQS protocol is able to prevent the receiver (i.e. one participant in the signature protocol) from forging a legal signature. According to our results, it can be seen that most AQS protocols which are based on the Zeng and Keitel (ZK) model are susceptible to a forgery attack. Furthermore, we present an improved idea of the ZK protocol. Finally, some supplement discussions and several interesting topics are provided.

  5. Tactics for Improving Parenting Skills (TIPS).

    ERIC Educational Resources Information Center

    Algozzine, Bob, Ed.; Ysseldyke, Jim, Ed.

    This manual presents 99 one-sheet informational brochures designed to improve parenting skills. Each brochure is in a format suitable for duplicating, folding, and distributing. Each parenting "tactic" offers references to related brochures. Tactics are grouped under the following broad areas: (1) home/family involvement (e.g., accepting "The…

  6. Antioxidant and Anti-stress Compounds Improve Regrowth of Cryopreserved Rubus Shoot Tips

    USDA-ARS?s Scientific Manuscript database

    Regrowth of plants after cryopreservation varies and resulting regrowth ranges from poor to excellent. Oxidative stress is a potential cause of damage in plant tissues. Antioxidants and anti-stress compounds may improve regrowth by preventing or repairing the damage. Lipoic acid (LA), glutathione (...

  7. Improved droplet-vitrification and histological studies of cryopreserved shoot tips of cultivated Jerusalem artichoke genotypes

    USDA-ARS?s Scientific Manuscript database

    Germplasm conservation of Jerusalem artichoke (Helianthus tuberosus L.) is crucial to preserve genetic diversity and to secure materials for genetic improvement. Long-term conservation is accomplished through cryopreservation, storing cells or tissues at an ultralow temperature in liquid nitrogen (-...

  8. Controlling the electric charge of gold nanoplatelets on an insulator by field emission nc-AFM

    NASA Astrophysics Data System (ADS)

    Baris, Bulent; Alchaar, Mohanad; Prasad, Janak; Gauthier, Sébastien; Dujardin, Erik; Martrou, David

    2018-03-01

    Charging of 2D Au nanoplatelets deposited on an insulating SiO2 substrate to or from the tip of a non-contact atomic force microscope (nc-AFM) is demonstrated. Charge transfer is controlled by monitoring the resonance frequency shift Δf(V) during the bias voltage ramp V applied to the tip-back electrode junction. The onset of charge transfer is revealed by a transition from a capacitive parabolic behavior to a constant Δf(V) region for both polarities. An analytical model, based on charging by electron field emission, shows that the field-emitted current saturates shortly after the onset of the charging, due to the limiting effect of the charge-induced rise of the Au platelet potential. The value of this current plateau depends only on the rate of the bias voltage ramp and on the value of the platelet/SiO2/back electrode capacitance. This analysis is confirmed by numerical simulations based on a virtual nc-AFM model that faithfully matches the experimental data. Our charging protocol could be used to tune the potential of the platelets at the single charge level.

  9. In vitro plantlet regeneration from nodal segments and shoot tips of Capsicum chinense Jacq. cv. Naga King Chili.

    PubMed

    Kehie, Mechuselie; Kumaria, Suman; Tandon, Pramod

    2012-03-01

    An in vitro regeneration protocol was developed for Capsicum chinense Jacq. cv. Naga King Chili, a very pungent chili cultivar and an important horticultural crop of Nagaland (Northeast India). Maximum number of shoot (13 ± 0.70) was induced with bud-forming capacity (BFC) index of 10.8, by culturing nodal segments in Murashige and Skoog (MS) medium supplemented with 18.16 μM Thidiazuron (TDZ) followed by 35.52 μM 6-benzylaminopurine (BAP). Using shoot tips as explants, multiple shoot (10 ± 0.37) (BFC 8.3) was also induced in MS medium fortified with either 18.16 μM TDZ or 35.52 μM BAP. Elongated shoots were best rooted in MS medium containing 5.70 μM indole-3-acetic acid (IAA). Rooted plantlets thus developed were hardened in 2-3 weeks time in plastic cups containing potting mixture of a 1:1 mix of soil and cow dung manure and then subsequently transferred to earthen pots. The regenerated plants did not show any variation in the morphology and growth as compared to the parent plant.

  10. The impact of protocol on nurses' role stress: a longitudinal perspective.

    PubMed

    Dodd-McCue, Diane; Tartaglia, Alexander; Veazey, Kenneth W; Streetman, Pamela S

    2005-04-01

    The study examined the impact of a protocol directed at increasing organ donation on the role stress and work attitudes of critical care nurses involved in potential organ donation cases. The research examined whether the protocol could positively affect nurses' perceptions of role stress, and if so, could the work environment improvements be sustained over time. The Family Communication Coordinator (FCC) protocol promotes effective communication during potential organ donation cases using a multidisciplinary team approach. Previous research found it associated with improved donation outcomes and with improved perceptions of role stress by critical care nurses. However, the previous study lacked methodological rigor necessary to determine causality and sustainability over time. The study used a quasi-experimental prospective longitudinal design. The sample included critical care nurses who had experience with potential organ donation cases with the protocol. Survey data were collected at 4 points over 2 years. Surveys used previously validated and reliable measures of role stress (role ambiguity, role conflict, role overload) and work attitudes (commitment, satisfaction). Interviews supplemented these data. The nurses' perceptions of role stress associated with potential organ donation cases dramatically dropped after the protocol was implemented. All measures of role stress, particularly role ambiguity and role conflict, showed statistically significant and sustained improvement. Nurses' professional, unit, and hospital commitment and satisfaction reflect an increasingly positive workplace. The results demonstrate that the FCC protocol positively influenced the workplace through its impact on role stress over the first 2 years following its implementation. The findings suggest that similar protocols may be appropriate in improving the critical care environment by reducing the stress and uncertainty of professionals involved in other end-of-life situations. However, the most striking implication relates to the reality of the workplace: meeting the goals of improved patient care outcomes and those of improving the healthcare work environment are not mutually exclusive and may be mutually essential.

  11. Aerodynamic performance of a wing with a deflected tip-mounted reverse half-delta wing

    NASA Astrophysics Data System (ADS)

    Lee, T.; Su, Y. Y.

    2012-11-01

    The impact of a tip-mounted 65°-sweep reverse half-delta wing (RHDW), set at different deflections, on the aerodynamic performance of a rectangular NACA 0012 wing was investigated experimentally at Re = 2.45 × 105. This study is a continuation of the work of Lee and Su (Exp Fluids 52(6):1593-1609, 2012) on the passive control of wing tip vortex by the use of a reverse half-delta wing. The present results show that for RHDW deflection with -5° ≤ δ ≤ +15°, the lift was found to increase nonlinearly with increasing δ compared to the baseline wing. The lift increment was accompanied by an increased total drag. For negative RHDW deflection with δ < -5°, the RHDW-induced lift decrement was, however, accompanied by an improved drag. The deflected RHDW also significantly modified and weakened the tip vortex, leading to a persistently lowered lift-induced drag, regardless of its deflection, compared to the baseline wing. Physical mechanisms responsible for the observed RHDW-induced phenomenon were also discussed.

  12. The sinusoidal probe: a new approach to improve electrode longevity

    PubMed Central

    Sohal, Harbaljit S.; Jackson, Andrew; Jackson, Richard; Clowry, Gavin J.; Vassilevski, Konstantin; O’Neill, Anthony; Baker, Stuart N.

    2014-01-01

    Micromotion between the brain and implanted electrodes is a major contributor to the failure of invasive brain–machine interfaces. Movements of the electrode tip cause recording instabilities while spike amplitudes decline over the weeks/months post-implantation due to glial cell activation caused by sustained mechanical trauma. We have designed a sinusoidal probe in order to reduce movement of the recording tip relative to the surrounding neural tissue. The probe was microfabricated from flexible materials and incorporated a sinusoidal shaft to minimize tethering forces and a 3D spheroid tip to anchor the recording site within the brain. Compared to standard microwire electrodes, the signal-to-noise ratio and local field potential power of sinusoidal probe recordings from rabbits was more stable across recording periods up to 678 days. Histological quantification of microglia and astrocytes showed reduced neuronal tissue damage especially for the tip region between 6 and 24 months post-implantation. We suggest that the micromotion-reducing measures incorporated into our design, at least partially, decreased the magnitude of gliosis, resulting in enhanced longevity of recording. PMID:24808859

  13. Nanoscale patterning of gold-coated optical fibers for improved plasmonic sensing

    NASA Astrophysics Data System (ADS)

    Antohe, Iulia; Spasic, Dragana; Delport, Filip; Li, Jiaqi; Lammertyn, Jeroen

    2017-05-01

    Merging surface plasmon resonance (SPR) to fiber optic (FO) technology has brought remarkable achievements in the field by offering attractive advantages over the conventional prism-based SPR platforms, such as simplicity, cost-effectiveness and miniaturization. However, the performance of the existing FO-SPR instruments mainly depends on the device surface condition and in particular on the structural aspect of the thin gold (Au) plasmonic film deposited on the FO substrate. In this work, a simple cost-effective colloidal lithography technique (CLT) was adapted and applied for the first time to the micrometer-sized FO substrate, to design end reflection-type FO-SPR sensors with periodic arrays of Au triangularly-shaped nanostructures on the Au mirror FO tip distal end. The nanopatterned FO-SPR sensor tips were afterwards subjected to refractometric measurements in a sucrose dilution series and subsequently compared with their non-patterned counterparts. It was observed that the spectral dips of the nanopatterned FO-SPR sensor tips were shifted towards longer wavelengths after CLT patterning. Moreover, the sensor sensitivity was improved with up to 25% compared to the conventional non-patterned FO-SPR devices. The obtained results represent important steps in the development of a new generation of FO-SPR sensors with improved performance, which can ultimately be used in various applications, ranging from food analysis and environmental monitoring, to health control and medical diagnosis.

  14. A Study on Micropipetting Detection Technology of Automatic Enzyme Immunoassay Analyzer.

    PubMed

    Shang, Zhiwu; Zhou, Xiangping; Li, Cheng; Tsai, Sang-Bing

    2018-04-10

    In order to improve the accuracy and reliability of micropipetting, a method of micro-pipette detection and calibration combining the dynamic pressure monitoring in pipetting process and quantitative identification of pipette volume in image processing was proposed. Firstly, the normalized pressure model for the pipetting process was established with the kinematic model of the pipetting operation, and the pressure model is corrected by the experimental method. Through the pipetting process pressure and pressure of the first derivative of real-time monitoring, the use of segmentation of the double threshold method as pipetting fault evaluation criteria, and the pressure sensor data are processed by Kalman filtering, the accuracy of fault diagnosis is improved. When there is a fault, the pipette tip image is collected through the camera, extract the boundary of the liquid region by the background contrast method, and obtain the liquid volume in the tip according to the geometric characteristics of the pipette tip. The pipette deviation feedback to the automatic pipetting module and deviation correction is carried out. The titration test results show that the combination of the segmented pipetting kinematic model of the double threshold method of pressure monitoring, can effectively real-time judgment and classification of the pipette fault. The method of closed-loop adjustment of pipetting volume can effectively improve the accuracy and reliability of the pipetting system.

  15. Robot training of upper limb in multiple sclerosis: comparing protocols with or without manipulative task components.

    PubMed

    Carpinella, Ilaria; Cattaneo, Davide; Bertoni, Rita; Ferrarin, Maurizio

    2012-05-01

    In this pilot study, we compared two protocols for robot-based rehabilitation of upper limb in multiple sclerosis (MS): a protocol involving reaching tasks (RT) requiring arm transport only and a protocol requiring both objects' reaching and manipulation (RMT). Twenty-two MS subjects were assigned to RT or RMT group. Both protocols consisted of eight sessions. During RT training, subjects moved the handle of a planar robotic manipulandum toward circular targets displayed on a screen. RMT protocol required patients to reach and manipulate real objects, by moving the robotic arm equipped with a handle which left the hand free for distal tasks. In both trainings, the robot generated resistive and perturbing forces. Subjects were evaluated with clinical and instrumental tests. The results confirmed that MS patients maintained the ability to adapt to the robot-generated forces and that the rate of motor learning increased across sessions. Robot-therapy significantly reduced arm tremor and improved arm kinematics and functional ability. Compared to RT, RMT protocol induced a significantly larger improvement in movements involving grasp (improvement in Grasp ARAT sub-score: RMT 77.4%, RT 29.5%, p=0.035) but not precision grip. Future studies are needed to evaluate if longer trainings and the use of robotic handles would significantly improve also fine manipulation.

  16. Adaptive Development

    NASA Technical Reports Server (NTRS)

    2005-01-01

    The goal of this research is to develop and demonstrate innovative adaptive seal technologies that can lead to dramatic improvements in engine performance, life, range, and emissions, and enhance operability for next generation gas turbine engines. This work is concentrated on the development of self-adaptive clearance control systems for gas turbine engines. Researchers have targeted the high-pressure turbine (HPT) blade tip seal location for following reasons: Current active clearance control (ACC) systems (e.g., thermal case-cooling schemes) cannot respond to blade tip clearance changes due to mechanical, thermal, and aerodynamic loads. As such they are prone to wear due to the required tight running clearances during operation. Blade tip seal wear (increased clearances) reduces engine efficiency, performance, and service life. Adaptive sealing technology research has inherent impact on all envisioned 21st century propulsion systems (e.g. distributed vectored, hybrid and electric drive propulsion concepts).

  17. Improving the lateral resolution of quartz tuning fork-based sensors in liquid by integrating commercial AFM tips into the fiber end.

    PubMed

    Gonzalez, Laura; Martínez-Martín, David; Otero, Jorge; de Pablo, Pedro José; Puig-Vidal, Manel; Gómez-Herrero, Julio

    2015-01-14

    The use of quartz tuning fork sensors as probes for scanning probe microscopy is growing in popularity. Working in shear mode, some methods achieve a lateral resolution comparable with that obtained with standard cantilevered probes, but only in experiments conducted in air or vacuum. Here, we report a method to produce and use commercial AFM tips in electrically driven quartz tuning fork sensors operating in shear mode in a liquid environment. The process is based on attaching a standard AFM tip to the end of a fiber probe which has previously been sharpened. Only the end of the probe is immersed in the buffer solution during imaging. The lateral resolution achieved is about 6 times higher than that of the etched microfiber on its own.

  18. Transjugular Intrahepatic Portosystemic Shunt for Treatment of Cirrhosis-related Chylothorax and Chylous Ascites: Single-institution Retrospective Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kikolski, Steven G., E-mail: skikolski@ucsd.edu; Aryafar, Hamed, E-mail: haryafar@ucsd.edu; Rose, Steven C., E-mail: scrose@ucsd.edu

    2013-08-01

    PurposeTo investigate the efficacy and safety of the use of transjugular intrahepatic portosystemic shunt (TIPS) creation to treat cirrhosis-related chylous collections (chylothorax and chylous ascites).MethodsWe retrospectively reviewed data from four patients treated for refractory cirrhosis-related chylous collections with TIPS at our institution over an 8 year period.ResultsOne patient had chylothorax, and three patients had concomitant chylothorax and chylous ascites. There were no major complications, and the only procedure-related complications occurred in two patients who had mild, treatable hepatic encephalopathy. All patients had improvement as defined by decreased need for thoracentesis or paracentesis, with postprocedure follow-up ranging from 19 to 491more » days.ConclusionTIPS is a safe procedure that is effective in the treatment of cirrhosis-related chylous collections.« less

  19. Twelve tips for applying the science of learning to health professions education.

    PubMed

    Gooding, H C; Mann, K; Armstrong, E

    2017-01-01

    Findings from the science of learning have clear implications for those responsible for teaching and curricular design. However, this data has been historically siloed from educators in practice, including those in health professions education. In this article, we aim to bring practical tips from the science of learning to health professions educators. We have chosen to organize the tips into six themes, highlighting strategies for 1) improving the processing of information, 2) promoting effortful learning for greater retention of knowledge over time, 3) applying learned information to new and varied contexts, 4) promoting the development of expertise, 5) harnessing the power of emotion for learning, and 6) teaching and learning in social contexts. We conclude with the importance of attending to metacognition in our learners and ourselves. Health professions education can be strengthened by incorporating these evidence-based techniques.

  20. System and method for improved rotor tip performance

    NASA Technical Reports Server (NTRS)

    Bussom, Richard (Inventor); McVeigh, Michael A. (Inventor); Narducci, Robert P. (Inventor); Zientek, Thomas A. (Inventor)

    2010-01-01

    Embodiments of systems and methods for enhancing the performance of rotary wing aircraft through reduced torque, noise and vibration are disclosed. In one embodiment, a method includes configuring the rotorcraft in a selected flight condition, communicating input signals to a control system operable to position sails coupled to tips of blades of a rotor assembly, processing the input signals according to a constraint condition to generate sail positional information, and transferring the sail positional information to the sail. Alternately, input signals may be communicated to a control system operable to position a plurality of sails, each sail having an aerodynamic shape and positioned proximate to a tip portion of the rotor blade. The input signals may be configured to rotate each sail about a longitudinal axis into a corresponding pitch angle independently of the other sails.

  1. Improving generalized inverted index lock wait times

    NASA Astrophysics Data System (ADS)

    Borodin, A.; Mirvoda, S.; Porshnev, S.; Ponomareva, O.

    2018-01-01

    Concurrent operations on tree like data structures is a cornerstone of any database system. Concurrent operations intended for improving read\\write performance and usually implemented via some way of locking. Deadlock-free methods of concurrency control are known as tree locking protocols. These protocols provide basic operations(verbs) and algorithm (ways of operation invocations) for applying it to any tree-like data structure. These algorithms operate on data, managed by storage engine which are very different among RDBMS implementations. In this paper, we discuss tree locking protocol implementation for General inverted index (Gin) applied to multiversion concurrency control (MVCC) storage engine inside PostgreSQL RDBMS. After that we introduce improvements to locking protocol and provide usage statistics about evaluation of our improvement in very high load environment in one of the world’s largest IT company.

  2. Analysis and testing of a space crane articulating joint testbed

    NASA Technical Reports Server (NTRS)

    Sutter, Thomas R.; Wu, K. Chauncey

    1992-01-01

    The topics are presented in viewgraph form and include: space crane concept with mobile base; mechanical versus structural articulating joint; articulating joint test bed and reference truss; static and dynamic characterization completed for space crane reference truss configuration; improved linear actuators reduce articulating joint test bed backlash; 1-DOF space crane slew maneuver; boom 2 tip transient response finite element dynamic model; boom 2 tip transient response shear-corrected component modes torque driver profile; peak root member force vs. slew time torque driver profile; and open loop control of space crane motion.

  3. Remote Navigation for Complex Arrhythmia

    PubMed Central

    Suman-Horduna, Irina; Babu-Narayan, Sonya V; Ernst, Sabine

    2013-01-01

    Magnetic navigation has been established as an alternative to conventional, manual catheter navigation for invasive electrophysiology interventions about a decade ago. Besides the obvious advantage of radiation protection for the operator who is positioned remotely from the patient, there are additional benefits of steering the tip of a very floppy catheter. This manuscript reviews the published evidence from simple arrhythmias in patients with normal cardiac anatomy to the most complex congenital heart disease. This progress was made possible by the introduction of improved catheters and most importantly irrigated-tip electrodes. PMID:26835041

  4. Flexible ureterorenoscopy: Tips and tricks.

    PubMed

    Somani, Bhaskar Kumar; Aboumarzouk, Omar; Srivastava, Aneesh; Traxer, Olivier

    2013-01-01

    With advancement in technology, improvement in endoscope and ancillary equipment, more complex procedures can be performed using flexible ureterorenoscopy. In this review article we provide a summary of flexible ureterorenoscopic procedures with "tips and tricks" for success for each type of procedure. It looks at the disposables used with flexible ureterorenoscopic procedures, set up and patient positioning for gaining access, insertion and handling of scope and the use of urethral access sheath. We also provide techniques for various flexible ureterorenoscopic procedures including management of renal stones, calyceal diverticula and upper tract urothelial tumours.

  5. Flexible ureterorenoscopy: Tips and tricks

    PubMed Central

    Somani, Bhaskar Kumar; Aboumarzouk, Omar; Srivastava, Aneesh; Traxer, Olivier

    2013-01-01

    With advancement in technology, improvement in endoscope and ancillary equipment, more complex procedures can be performed using flexible ureterorenoscopy. In this review article we provide a summary of flexible ureterorenoscopic procedures with “tips and tricks” for success for each type of procedure. It looks at the disposables used with flexible ureterorenoscopic procedures, set up and patient positioning for gaining access, insertion and handling of scope and the use of urethral access sheath. We also provide techniques for various flexible ureterorenoscopic procedures including management of renal stones, calyceal diverticula and upper tract urothelial tumours. PMID:23662000

  6. The 30-kW ammonia arcjet technology

    NASA Technical Reports Server (NTRS)

    Deininger, W. D.; Chopra, A.; Pivirotto, T. J.; Goodfellow, K. D.; Barnett, J. W.

    1990-01-01

    The technical results are summarized of a 30 kW class ammonia propellant arcjet technology program. Evaluation of previous arcjet thruster performance, including materials analysis of used thruster components, led to the design of an arcjet with improved performance and thermal characteristics. Tests of the new engine demonstrated that engine performance is relatively insensitive to cathode tip geometry. Other data suggested a maximum sustainable arc length for a given thruster configuration, beyond which the arc may reconfigure in a destructive manner. A flow controller calibration error was identified. This error caused previously reported values of specific impulse and thrust efficiency to be 20 percent higher than the real values. Corrected arcjet performance data are given. Duration tests of 413 and 252 hours, and several tests 100 hours in duration, were performed. The cathode tip erosion rate increased with increasing arc current. Elimination of power source ripple did not affect cathode tip whisker growth. Results of arcjet modeling, diagnostic development and mission analyses are also discussed. The 30 kW ammonia arcjet may now be considered ready for development for a flight demonstration, but widespread application of 30 kW class arcjet will require improved efficiency and lifetime.

  7. Ten tips for authors of scientific articles.

    PubMed

    Hong, Sung-Tae

    2014-08-01

    Writing a good quality scientific article takes experience and skill. I propose 'Ten Tips' that may help to improve the quality of manuscripts for scholarly journals. It is advisable to draft first version of manuscript and revise it repeatedly for consistency and accuracy of the writing. During the drafting and revising the following tips can be considered: 1) focus on design to have proper content, conclusion, points compliant with scope of the target journal, appropriate authors and contributors list, and relevant references from widely visible sources; 2) format the manuscript in accordance with instructions to authors of the target journal; 3) ensure consistency and logical flow of ideas and scientific facts; 4) provide scientific confidence; 5) make your story interesting for your readers; 6) write up short, simple and attractive sentences; 7) bear in mind that properly composed and reflective titles increase chances of attracting more readers; 8) do not forget that well-structured and readable abstracts improve citability of your publications; 9) when revising adhere to the rule of 'First and Last' - open your text with topic paragraph and close it with resolution paragraph; 10) use connecting words linking sentences within a paragraph by repeating relevant keywords.

  8. Ten Tips for Authors of Scientific Articles

    PubMed Central

    2014-01-01

    Writing a good quality scientific article takes experience and skill. I propose 'Ten Tips' that may help to improve the quality of manuscripts for scholarly journals. It is advisable to draft first version of manuscript and revise it repeatedly for consistency and accuracy of the writing. During the drafting and revising the following tips can be considered: 1) focus on design to have proper content, conclusion, points compliant with scope of the target journal, appropriate authors and contributors list, and relevant references from widely visible sources; 2) format the manuscript in accordance with instructions to authors of the target journal; 3) ensure consistency and logical flow of ideas and scientific facts; 4) provide scientific confidence; 5) make your story interesting for your readers; 6) write up short, simple and attractive sentences; 7) bear in mind that properly composed and reflective titles increase chances of attracting more readers; 8) do not forget that well-structured and readable abstracts improve citability of your publications; 9) when revising adhere to the rule of 'First and Last' - open your text with topic paragraph and close it with resolution paragraph; 10) use connecting words linking sentences within a paragraph by repeating relevant keywords. PMID:25120310

  9. On the Importance of Spatial Resolution for Flap Side Edge Noise Prediction

    NASA Technical Reports Server (NTRS)

    Mineck, Raymond E.; Khorrami, Mehdi R.

    2017-01-01

    A spatial resolution study of flap tip flow and the effects on the farfield noise signature for an 18%-scale, semispan Gulfstream aircraft model are presented. The NASA FUN3D unstructured, compressible Navier-Stokes solver was used to perform the highly resolved, time-dependent, detached eddy simulations of the flow field associated with the flap for this high-fidelity aircraft model. Following our previous work on the same model, the latest computations were undertaken to determine the causes of deficiencies observed in our earlier predictions of the steady and unsteady surface pressures and off-surface flow field at the flap tip regions, in particular the outboard tip area, where the presence of a cavity at the side-edge produces very complex flow features and interactions. The present results show gradual improvement in steady loading at the outboard flap edge region with increasing spatial resolution, yielding more accurate fluctuating surface pressures, off-surface flow field, and farfield noise with improved high-frequency content when compared with wind tunnel measurements. The spatial resolution trends observed in the present study demonstrate that the deficiencies reported in our previous computations are mostly caused by inadequate spatial resolution and are not related to the turbulence model.

  10. Fiber optic probe having fibers with endfaces formed for improved coupling efficiency and method using same

    DOEpatents

    O`Rourke, P.E.; Livingston, R.R.

    1995-03-28

    A fiber optic probe is disclosed for detecting scattered light, with transmitting and receiving fibers having slanted ends and bundled together to form a bevel within the tip of the probe. The probe comprises a housing with a transparent window across its tip for protecting the transmitting and receiving fibers held therein. The endfaces of the fibers are slanted, by cutting, polishing and the like, so that they lie in a plane that is not perpendicular to the longitudinal axis of the respective fiber. The fibers are held in the tip of the probe using an epoxy and oriented so that lines normal to the slanted endfaces are divergent with respect to one another. The epoxy, which is positioned substantially between the transmitting and receiving fibers, is tapered so that the transmitting fiber, the epoxy and the receiving fiber form a bevel of not more than 20 degrees. The angled fiber endfaces cause directing of the light cones toward each other, resulting in improved light coupling efficiency. A light absorber, such as carbon black, is contained in the epoxy to reduce crosstalk between the transmitting and receiving fibers. 3 figures.

  11. Fiber optic probe having fibers with endfaces formed for improved coupling efficiency and method using same

    DOEpatents

    O'Rourke, Patrick E.; Livingston, Ronald R.

    1995-01-01

    A fiber optic probe for detecting scattered light, with transmitting and receiving fibers having slanted ends and bundled together to form a bevel within the tip of the probe. The probe comprises a housing with a transparent window across its tip for protecting the transmitting and receiving fibers held therein. The endfaces of the fibers are slanted, by cutting, polishing and the like, so that they lie in a plane that is not perpendicular to the longitudinal axis of the respective fiber. The fibers are held in the tip of the probe using an epoxy and oriented so that lines normal to the slanted endfaces are divergent with respect to one another. The epoxy, which is positioned substantially between the transmitting and receiving fibers, is tapered so that the transmitting fiber, the epoxy and the receiving fiber form a bevel of not more than 20 degrees. The angled fiber endfaces cause directing of the light cones toward each other, resulting in improved light coupling efficiency. A light absorber, such as carbon black, is contained in the epoxy to reduce crosstalk between the transmitting and receiving fibers.

  12. Thrombolysis ImPlementation in Stroke (TIPS): evaluating the effectiveness of a strategy to increase the adoption of best evidence practice – protocol for a cluster randomised controlled trial in acute stroke care

    PubMed Central

    2014-01-01

    Background Stroke is a leading cause of death and disability internationally. One of the three effective interventions in the acute phase of stroke care is thrombolytic therapy with tissue plasminogen activator (tPA), if given within 4.5 hours of onset to appropriate cases of ischaemic stroke. Objectives To test the effectiveness of a multi-component multidisciplinary collaborative approach compared to usual care as a strategy for increasing thrombolysis rates for all stroke patients at intervention hospitals, while maintaining accepted benchmarks for low rates of intracranial haemorrhage and high rates of functional outcomes for both groups at three months. Methods and design A cluster randomised controlled trial of 20 hospitals across 3 Australian states with 2 groups: multi- component multidisciplinary collaborative intervention as the experimental group and usual care as the control group. The intervention is based on behavioural theory and analysis of the steps, roles and barriers relating to rapid assessment for thrombolysis eligibility; it involves a comprehensive range of strategies addressing individual-level and system-level change at each site. The primary outcome is the difference in tPA rates between the two groups post-intervention. The secondary outcome is the proportion of tPA treated patients in both groups with good functional outcomes (modified Rankin Score (mRS <2) and the proportion with intracranial haemorrhage (mRS ≥2), compared to international benchmarks. Discussion TIPS will trial a comprehensive, multi-component and multidisciplinary collaborative approach to improving thrombolysis rates at multiple sites. The trial has the potential to identify methods for optimal care which can be implemented for stroke patients during the acute phase. Study findings will include barriers and solutions to effective thrombolysis implementation and trial outcomes will be published whether significant or not. Trial registration Australian New Zealand Clinical Trials Registry: ACTRN12613000939796 PMID:24666591

  13. Sports Supplements

    MedlinePlus

    ... supplements. Instead, try these tips for getting better game: Make downtime a priority. Studies show that teens ... Meditating or visualizing your success during the next game may improve your performance; sitting quietly and focusing ...

  14. Find a Massage Therapist

    MedlinePlus

    ... tools to market your massage practice, expand your business and improve your professional growth. Explore Career Guidance » Take Care of Your Practice Marketing Tools Client Experience/Intake Forms Self-Care Tips ...

  15. A demonstration of the value of spacecraft computers

    NASA Astrophysics Data System (ADS)

    Jenkins, R. E.

    1984-09-01

    The Transit Improvement Program TIP satellites were designed to upgrade the navigation satellite system. One of the improvements made in connection with these satellites is related to the employment of a general-purpose minicomputer. A description is provided of the uses of the TIP/Nova flight computer to overcome some early failures in the spacecraft development which, although later corrected, could have jeopardized the entire program. The flight computer and its software is discussed, taking into account the delayed command program, and the telemetry storage program. The effect of the failures is considered along with the post-launch operations. Attention is given to power management, spin-up operations, the firing of the orbit adjust rocket, the tumble-thrust program, a digital phase-locked loop for de-tumble, and the generation of a tumble motion.

  16. Progressing single biomolecule force spectroscopy measurements for the screening of DNA binding agents

    NASA Astrophysics Data System (ADS)

    Zhang, Wenke; Barbagallo, Romina; Madden, Claire; Roberts, Clive J.; Woolford, Alison; Allen, Stephanie

    2005-10-01

    Recent studies have indicated that the force-extension properties of single molecules of double stranded (ds) DNA are sensitive to the presence of small molecule DNA binding agents, and also to their mode of binding. These observations raise the possibility of using this approach as a highly sensitive tool for the screening of such agents. However, particularly for studies employing the atomic force microscope (AFM), several non-trivial barriers hinder the progress of this approach to the non-specialist arena and hence also the full realization of this possibility. In this paper, we therefore address a series of key reproducibility and metrological issues associated with this type of measurement. Specifically, we present an improved immobilization method that covalently anchors one end (5' end) of a dual labelled (5'-thiol, 3'-biotin) p53 DNA molecule onto a gold substrate via gold-thiol chemistry, whilst the biotinylated 3' end is available for 'pick-up' using a streptavidin modified AFM tip. We also show that co-surface immobilization of DNA with 6-mercapto-1-hexanol (MCH) can also lead to a further increase the measured contour length. We demonstrate the impact of these improved protocols through the observation of the cooperative transition plateau in a DNA fragment of approximately 118 bp, a significantly smaller fragment than previously investigated. The results of a comparative study of the effects of a model minor groove binder (Hoechst 33258) and an intercalating drug (proflavine), alone, as a mixture and under different buffer conditions, are also presented.

  17. Novel fiber optic tip designs and devices for laser surgery

    NASA Astrophysics Data System (ADS)

    Hutchens, Thomas Clifton

    Fiber optic delivery of laser energy has been used for years in various types of surgical procedures in the human body. Optical energy provides several benefits over electrical or mechanical surgery, including the ability to selectively target specific tissue types while preserving others. Specialty fiber optic tips have also been introduced to further customize delivery of laser energy to the tissue. Recent evolution in lasers and miniaturization has opened up opportunities for many novel surgical techniques. Currently, ophthalmic surgeons use relatively invasive mechanical tools to dissect retinal deposits which occur in proliferative diabetic retinopathy. By using the tight focusing properties of microspheres combined with the short optical penetration depth of the Erbium:YAG laser and mid-IR fiber delivery, a precise laser scalpel can be constructed as an alternative, less invasive and more precise approach to this surgery. Chains of microspheres may allow for a self limiting ablation depth of approximately 10 microm based on the defocusing of paraxial rays. The microsphere laser scalpel may also be integrated with other surgical instruments to reduce the total number of handpieces for the surgeon. In current clinical laser lithotripsy procedures, poor input coupling of the Holmium:YAG laser energy frequently damages and requires discarding of the optical fiber. However, recent stone ablation studies with the Thulium fiber laser have provided comparable results to the Ho:YAG laser. The improved spatial beam profile of the Thulium fiber laser can also be efficiently coupled into a fiber approximately one third the diameter and reduces the risk of damaging the fiber input. For this reason, the trunk optical fiber minus the distal fiber tip can be preserved between procedures. The distal fiber tip, which degrades during stone ablation, could be made detachable and disposable. A novel, low-profile, twist-locking, detachable distal fiber tip interface was designed, assembled, and tested for use in Thulium fiber laser lithotripsy. A 1.00-mm-outer-diameter detachable fiber tip interface was designed, constructed, and tested ex vivo on urinary stones in the laboratory. Similar stone ablation rates between the previously studied tapered distal fiber tip and the detachable fiber tip were measured. For urologists desiring faster TFL lithotripsy procedures, the incorporation of detachable distal fiber tips allows for rapid replacement of damaged fiber tips without concern about the laser to trunk fiber connection. This method for preserving the trunk fiber could be a motivation for integrating a dedicated laser fiber into the ureteroscope, with detachable distal tips, thus freeing the working channel for the use of other surgical instruments. During laser lithotripsy, distal fiber tip degradation increases as the fiber core diameter decreases. However, smaller fiber diameters (≤ 200 microm) are more desirable because of increased saline irrigation rates in the single working channel of the ureteroscope and less impact on ureteroscope deflection. A hollow fiber cap is proposed to reduced fiber tip degradation in small diameter fibers, without compromising stone ablation rates. The disadvantage of the hollow fiber tip observed in the study is the increase in stone retropulsion. However, integrating the hollow fiber tip with a clinically used stone basket may allow for a robust stone ablation instrument that also minimizes retropulsion. These surgical approaches involving novel specialty fiber optic tip designs are discussed in this thesis.

  18. Continuous-variable measurement-device-independent quantum key distribution with virtual photon subtraction

    NASA Astrophysics Data System (ADS)

    Zhao, Yijia; Zhang, Yichen; Xu, Bingjie; Yu, Song; Guo, Hong

    2018-04-01

    The method of improving the performance of continuous-variable quantum key distribution protocols by postselection has been recently proposed and verified. In continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocols, the measurement results are obtained from untrusted third party Charlie. There is still not an effective method of improving CV-MDI QKD by the postselection with untrusted measurement. We propose a method to improve the performance of coherent-state CV-MDI QKD protocol by virtual photon subtraction via non-Gaussian postselection. The non-Gaussian postselection of transmitted data is equivalent to an ideal photon subtraction on the two-mode squeezed vacuum state, which is favorable to enhance the performance of CV-MDI QKD. In CV-MDI QKD protocol with non-Gaussian postselection, two users select their own data independently. We demonstrate that the optimal performance of the renovated CV-MDI QKD protocol is obtained with the transmitted data only selected by Alice. By setting appropriate parameters of the virtual photon subtraction, the secret key rate and tolerable excess noise are both improved at long transmission distance. The method provides an effective optimization scheme for the application of CV-MDI QKD protocols.

  19. The Improving Literacy through School Libraries Program of "No Child Left Behind": Tips for Writing a Winning Grant Proposal. ERIC Digest.

    ERIC Educational Resources Information Center

    Mardis, Marcia A.

    This ERIC Digest is intended to help eligible school library personnel write an effective proposal for the "Improving Literacy Through School Libraries" (LSL) grant program, which provides funding for high-need K-12 school library programs to improve reading achievement by providing students with increased access to school library…

  20. Delta Alert: Expanding Gerotrauma Criteria to Improve Patient Outcomes: A 2-Year Study.

    PubMed

    Wiles, Lynn L; Day, Mark D

    Because of their decreased physical reserve and increased risk of complications, the geriatric trauma patient (GTP) population warrants heightened awareness by clinical staff. The purpose of this study is to determine whether the institution of a third-tier trauma protocol results in a change in GTP outcomes, complications, and mortality rates. Researchers conducted a retrospective review of 2 years of data from the trauma registry, hospital quality improvement audits, and patient charts to examine what, if any, patient outcomes were impacted by the institution of the expanded GTP protocol. Sample homogeneity was determined. Emergency department (ED) length of stay and time to the operating room decreased in the protocol cohort. The rate of complications decreased from 16.4% preprotocol to 1.6% postprotocol. Discharge to home rates in the GTP population improved from 31% preprotocol to nearly 77% postimplementation of the protocol. The expanded GTP protocol front loads evaluation and resuscitation to be consistent with ED trauma protocols already in place. By fast-tracking radiology and laboratory testing, patients injuries are identified and the appropriate consultations are initiated. Appropriate inpatient nursing unit placement is identified or treatment and discharge from the ED are expedited. The expanded GTP protocol provided early and comprehensive evaluation and interventions for GTPs who fall outside of traditional trauma alert criteria. Patients spend less time in the ED and the hospital. Patients had decreased length of stay in the ED, less complications, and return to home rates showed significant improvement after the protocol was implemented.

  1. Management of Transjugular Intrahepatic Portosystemic Shunt (TIPS)-associated Refractory Hepatic Encephalopathy by Shunt Reduction Using the Parallel Technique: Outcomes of a Retrospective Case Series

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cookson, Daniel T., E-mail: danielthomascookson@yahoo.co.uk; Zaman, Zubayr; Gordon-Smith, James

    2011-02-15

    Purpose: To investigate the reproducibility and technical and clinical success of the parallel technique of transjugular intrahepatic portosystemic shunt (TIPS) reduction in the management of refractory hepatic encephalopathy (HE). Materials and Methods: A 10-mm-diameter self-expanding stent graft and a 5-6-mm-diameter balloon-expandable stent were placed in parallel inside the existing TIPS in 8 patients via a dual unilateral transjugular approach. Changes in portosystemic pressure gradient and HE grade were used as primary end points. Results: TIPS reduction was technically successful in all patients. Mean {+-} standard deviation portosystemic pressure gradient before and after shunt reduction was 4.9 {+-} 3.6 mmHg (range,more » 0-12 mmHg) and 10.5 {+-} 3.9 mmHg (range, 6-18 mmHg). Duration of follow-up was 137 {+-} 117.8 days (range, 18-326 days). Clinical improvement of HE occurred in 5 patients (62.5%) with resolution of HE in 4 patients (50%). Single episodes of recurrent gastrointestinal hemorrhage occurred in 3 patients (37.5%). These were self-limiting in 2 cases and successfully managed in 1 case by correction of coagulopathy and blood transfusion. Two of these patients (25%) died, one each of renal failure and hepatorenal failure. Conclusion: The parallel technique of TIPS reduction is reproducible and has a high technical success rate. A dual unilateral transjugular approach is advantageous when performing this procedure. The parallel technique allows repeat bidirectional TIPS adjustment and may be of significant clinical benefit in the management of refractory HE.« less

  2. Indication-Based Ordering: A New Paradigm for Glycemic Control in Hospitalized Inpatients

    PubMed Central

    Lee, Joshua; Clay, Brian; Zelazny, Ziband; Maynard, Gregory

    2008-01-01

    Background Inpatient glycemic control is a constant challenge. Institutional insulin management protocols and structured order sets are commonly advocated but poorly studied. Effective and validated methods to integrate algorithmic protocol guidance into the insulin ordering process are needed. Methods We introduced a basic structured set of computerized insulin orders (Version 1), and later introduced a paper insulin management protocol, to assist users with the order set. Metrics were devised to assess the impact of the protocol on insulin use, glycemic control, and hypoglycemia using pharmacy data and point of care glucose tests. When incremental improvement was seen (as described in the results), Version 2 of the insulin orders was created to further streamline the process. Results The percentage of regimens containing basal insulin improved with Version 1. The percentage of patient days with hypoglycemia improved from 3.68% at baseline to 2.59% with Version 1 plus the paper insulin management protocol, representing a relative risk for hypoglycemic day of 0.70 [confidence interval (CI) 0.62, 0.80]. The relative risk of an uncontrolled (mean glucose over 180 mg/dl) patient stay was reduced to 0.84 (CI 0.77, 0.91) with Version 1 and was reduced further to 0.73 (CI 0.66, 0.81) with the paper protocol. Version 2 used clinician-entered patient parameters to guide protocol-based insulin ordering and simultaneously improved the flexibility and ease of ordering over Version 1. Conclusion Patient parameter and protocol-based clinical decision support, added to computerized provider order entry, has a track record of improving glycemic control indices. This justifies the incorporation of these algorithms into online order management. PMID:19885198

  3. Parenting Tips: How to Improve Toddler Behavior

    MedlinePlus

    ... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization and proceeds from Web advertising help support our mission. Mayo Clinic does not ...

  4. Associations of Tipped and Untipped Service Work with Poor Mental Health in a Nationally Representative Cohort of Adolescents Followed into Adulthood.

    PubMed

    Andrea, Sarah B; Messer, Lynne C; Marino, Miguel; Boone-Heinonen, Janne

    2018-06-11

    Precarious work is concentrated in the service industry in the United States and is a risk factor for poor mental health. Service occupations in which workers receive tips are potentially more precarious due to unstable schedule, income, and lack of benefits. We tested hypotheses that individuals working in tipped service occupations have greater odds of experiencing poor mental health (self-reported depression, sleep problems, and/or greater perceived stress) relative to individuals in untipped service and non-service occupations using cross-sectional data from the National Longitudinal study of Adolescent to Adult Health dataset (Wave IV:2007-2008; age 24-33 years). To improve comparability of occupation types, propensity-scores were computed as a function of childhood factors, then used to construct a sample of 2,815 women and 2,586 men. In gender-stratified multivariable regression, women in tipped service had greater odds of reporting depression diagnosis or symptoms relative to women in non-service work (Odds Ratio:1.61; 95% Confidence Interval:1.11,2.34). Associations of similar magnitude for sleep problems and perceived stress were observed among women, but were not significant; all associations were close to the null among men. Further research is necessary to understand the factors that underlie differences in poor mental health in tipped and untipped service versus non-service workers.

  5. Transjugular intrahepatic portosystemic shunt creation for cirrhotic portal hypertension is well tolerated among patients with portal vein thrombosis.

    PubMed

    Merola, Jonathan; Fortune, Brett E; Deng, Yanhong; Ciarleglio, Maria; Amirbekian, Smbat; Chaudhary, Noami; Shanbhogue, Alampady; Ayyagari, Rajasekhara; Rodriguez-Davalos, Manuel I; Teperman, Lewis; Charles, Hearns W; Sigal, Samuel H

    2018-06-01

    Portal vein thrombosis (PVT) develops in cirrhotic patients because of stagnation of blood flow. Transjugular intrahepatic portosystemic shunt (TIPS) creates a low-resistance conduit that restores portal venous patency and blood flow. The effect of PVT on transplant-free survival in cirrhotic patients undergoing TIPS creation was evaluated. A multicenter, retrospective cohort study of patients who underwent TIPS creation for cirrhotic portal hypertension was carried out. A Cox model with propensity score adjustment was developed to evaluate the effect of PVT on 90-day and 3-year transplant-free survival. A subgroup analysis examining mortality of those with superior and inferior PVT was also carried out. A total of 252 consecutive TIPS creations were assessed, including 65 in patients with PVT. Survival of patients with high Model for End-stage Liver Disease scores (≥18) and PVT was not statistically different compared with patients with low Model for End-stage Liver Disease scores (<18) and no PVT at 90 days (P=0.46) and 3 years (P=0.42). Those with superior PVT had improved 90-day and 3-year survival both compared with patients with a inferior PVT and those without a PVT (P<0.01, all cases). The presence of PVT does not impair the prognosis of patients following TIPS creation, particularly in patients with superior portal occlusion.

  6. Analysis of Tip Vortices Identified in the Instantaneous Wake of a Horizontal-Axis Model Wind Turbine Placed in a Turbulent Boundary Layer

    NASA Astrophysics Data System (ADS)

    Jain, Akash; Mehdi, Faraz; Sheng, Jian

    2014-11-01

    The near-wake field, a short region characterized by the physical specifications of a turbine, is of particular interest for flow-structure interactions responsible for asymmetric loadings, premature structural breakdown, noise generation etc. Helical tip vortices constitute a distinctive feature of this region and are dependent not only on the turbine geometry but also on the incoming flow profile. High-spatial resolution PIV measurements are made in the wake of a horizontal-axis model wind turbine embedded in a neutrally stratified turbulent boundary layer. The data is acquired over consecutive locations up to 10 diameters downstream of the turbine but the focus here is on the tip vortices identified in the instantaneous fields. Contrary to previous studies, both top and bottom tip vortices are clearly distinguishable in either ensemble fields or instantaneous realizations. The streamwise extent of these vortices stretches from the turbine till they merge into the expanding mid-span wake. The similarities and differences in the top and bottom tip vortices are explored through the evolution of their statistics. In particular, the distributions of the loci of vortex cores and their circulations are compared. The information will improve our understanding of near wake vortical dynamics, provide data for model validation, and aid in the devise of flow control strategies.

  7. SMART micro-scissors with dual motors and OCT sensors (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Yeo, Chaebeom; Jang, Seonjin; Park, Hyun-cheol; Gehlbach, Peter L.; Song, Cheol

    2017-02-01

    Various end-effectors of microsurgical instruments have been developed and studied. Also, many approaches to stabilize the tool-tip using robotics have been studied such as the steady hand robot system, Micron, and SMART system. In our previous study, the horizontal SMART micro-scissors with a common path swept source OCT distance and one linear piezoelectric (PZT) motor was demonstrated as a microsurgical system. Because the outer needle is connected with a mechanical handle and moved to engage the tool tip manually, the tool tip position is instantaneously changed during the engaging. The undesirable motion can make unexpected tissue damages and low surgical accuracy. In this study, we suggest a prototype horizontal SMART micro-scissors which has dual OCT sensors and two motors to improve the tremor cancellation. Dual OCT sensors provide two distance information. Front OCT sensor detects a distance from the sample surface to the tool tip. Rear OCT sensors gives current PZT motor movement, acting like a motor encoder. The PZT motor can compensate the hand tremor with a feedback loop control. The manual engaging of tool tip in previous SMART system is replaced by electrical engaging using a squiggle motor. Compared with previous study, this study showed better performance in the hand tremor reduction. From the result, the SMART with automatic engaging may become increasingly valuable in microsurgical instruments.

  8. A translating stage system for µ-PIV measurements surrounding the tip of a migrating semi-infinite bubble.

    PubMed

    Smith, B J; Yamaguchi, E; Gaver, D P

    2010-01-01

    We have designed, fabricated and evaluated a novel translating stage system (TSS) that augments a conventional micro particle image velocimetry (µ-PIV) system. The TSS has been used to enhance the ability to measure flow fields surrounding the tip of a migrating semi-infinite bubble in a glass capillary tube under both steady and pulsatile reopening conditions. With conventional µ-PIV systems, observations near the bubble tip are challenging because the forward progress of the bubble rapidly sweeps the air-liquid interface across the microscopic field of view. The translating stage mechanically cancels the mean bubble tip velocity, keeping the interface within the microscope field of view and providing a tenfold increase in data collection efficiency compared to fixed-stage techniques. This dramatic improvement allows nearly continuous observation of the flow field over long propagation distances. A large (136-frame) ensemble-averaged velocity field recorded with the TSS near the tip of a steadily migrating bubble is shown to compare well with fixed-stage results under identical flow conditions. Use of the TSS allows the ensemble-averaged measurement of pulsatile bubble propagation flow fields, which would be practically impossible using conventional fixed-stage techniques. We demonstrate our ability to analyze these time-dependent two-phase flows using the ensemble-averaged flow field at four points in the oscillatory cycle.

  9. Behavior of Tip-Steerable Needles in ex vivo and in vivo Tissue

    PubMed Central

    Majewicz, Ann; Marra, Steven P.; van Vledder, Mark G.; Lin, MingDe; Choti, Michael A.; Song, Danny Y.; Okamura, Allison M.

    2012-01-01

    Robotic needle steering is a promising technique to improve the effectiveness of needle-based clinical procedures, such as biopsies and ablation, by computer-controlled, curved insertions of needles within solid organs. In this paper, we explore the capabilities, challenges, and clinical relevance of asymmetric-tip needle steering though experiments in ex vivo and in vivo tissue. We evaluate the repeatability of needle insertion in inhomogeneous biological tissue and compare ex vivo and in vivo needle curvature and insertion forces. Steerable needles curved more in kidney than in liver and prostate, likely due to differences in tissue properties. Pre-bent needles produced higher insertion forces in liver and more curvature in vivo than ex vivo. When compared to straight stainless steel needles, steerable needles did not cause a measurable increase in tissue damage and did not exert more force during insertion. The minimum radius of curvature achieved by pre-bent needles was 5.23 cm in ex vivo tissue, and 10.4 cm in in vivo tissue. The curvatures achieved by bevel tip needles were negligible for in vivo tissue. The minimum radius of curvature for bevel tip needles in ex vivo tissue was 16.4 cm; however, about half of the bevel tip needles had negligible curvatures. We also demonstrate a potential clinical application of needle steering by targeting and ablating overlapping regions of cadaveric canine liver. PMID:22711767

  10. Tips and tricks for preparing lampbrush chromosome spreads from Xenopus tropicalis oocytes.

    PubMed

    Penrad-Mobayed, May; Kanhoush, Rasha; Perrin, Caroline

    2010-05-01

    Due to their large size and fine organization, lampbrush chromosomes (LBCs) of amphibian oocytes have been for decades one of the favorite tools of biologists for the analysis of transcriptional and post-transcriptional processes at the cytological level. The emergence of the diploid Xenopus tropicalis amphibian as a model organism for vertebrate developmental genetics and the accumulation of sequence data made available by its recent genomic sequencing, strongly revive the interest of LBCs as a powerful tool to study genes expressed during oogenesis. We describe here a detailed protocol for preparing LBCs from X. tropicalis oocyte and give practical advice to encourage a large number of researchers to become familiar with these chromosomes.

  11. Questions for Your Prospective Massage Therapist

    MedlinePlus

    ... tools to market your massage practice, expand your business and improve your professional growth. Explore Career Guidance » Take Care of Your Practice Marketing Tools Client Experience/Intake Forms Self-Care Tips ...

  12. TIP hypospadias repair: A pediatric urology indicator operation.

    PubMed

    Snodgrass, Warren; Bush, Nicol

    2016-02-01

    We review development and evolution of TIP hypospadias repair, including technical changes made to improve its results. We also discuss general risk factors for hypospadias surgical complications. We describe use of a database with prospective data entry to first identify our most common complications and their frequency, and then to monitor results of technical modifications made to reduce their occurrence. Multiple logistic regression of various factors recorded in the database was done to identify those predicting increased risk for urethroplasty complications. Fistula and glans dehiscence are the two most common complications we encountered after TIP repair. Changes in urethral plate tubularization and barrier layers covering the neourethra resulted in a significant reduction in fistulas after proximal TIP. Changes in glansplasty sutures and use of preoperative testosterone to increase glans size did not reduce likelihood for dehiscence, whereas increasing the extent of glans wings dissection did. Logistic regression analysis confirmed proximal meatal location and reoperation predicted increased complications, but also identified glans width ≤ 14 mm as an independent risk factor for hypospadias urethroplasty complications. Systematic, prospective data collection facilitated identification of complications and their risk factors, and provided a means to assess results of modifications made to address them. Limiting the algorithm used for hypospadias repair increases expertise in those techniques used. Reported low surgical volumes for proximal hypospadias repair suggest subspecialization of these cases be carried out so that designated surgeons can achieve sufficient volume to analyze their results and make improvements. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  13. Study of modification methods of probes for critical-dimension atomic-force microscopy by the deposition of carbon nanotubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ageev, O. A., E-mail: ageev@sfedu.ru; Bykov, Al. V.; Kolomiitsev, A. S.

    2015-12-15

    The results of an experimental study of the modification of probes for critical-dimension atomicforce microscopy (CD-AFM) by the deposition of carbon nanotubes (CNTs) to improve the accuracy with which the surface roughness of vertical walls is determined in submicrometer structures are presented. Methods of the deposition of an individual CNT onto the tip of an AFM probe via mechanical and electrostatic interaction between the probe and an array of vertically aligned carbon nanotubes (VACNTs) are studied. It is shown that, when the distance between the AFM tip and a VACNT array is 1 nm and the applied voltage is withinmore » the range 20–30 V, an individual carbon nanotube is deposited onto the tip. On the basis of the results obtained in the study, a probe with a carbon nanotube on its tip (CNT probe) with a radius of 7 nm and an aspect ratio of 1:15 is formed. Analysis of the CNT probe demonstrates that its use improves the resolution and accuracy of AFM measurements, compared with the commercial probe, and also makes it possible to determine the roughness of the vertical walls of high-aspect structures by CD-AFM. The results obtained can be used to develop technological processes for the fabrication and reconditioning of special AFM probes, including those for CD-AFM, and procedures for the interoperational express monitoring of technological process parameters in the manufacturing of elements for micro- and nanoelectronics and micro- and nanosystem engineering.« less

  14. Optimization of wireless sensor networks based on chicken swarm optimization algorithm

    NASA Astrophysics Data System (ADS)

    Wang, Qingxi; Zhu, Lihua

    2017-05-01

    In order to reduce the energy consumption of wireless sensor network and improve the survival time of network, the clustering routing protocol of wireless sensor networks based on chicken swarm optimization algorithm was proposed. On the basis of LEACH agreement, it was improved and perfected that the points on the cluster and the selection of cluster head using the chicken group optimization algorithm, and update the location of chicken which fall into the local optimum by Levy flight, enhance population diversity, ensure the global search capability of the algorithm. The new protocol avoided the die of partial node of intensive using by making balanced use of the network nodes, improved the survival time of wireless sensor network. The simulation experiments proved that the protocol is better than LEACH protocol on energy consumption, also is better than that of clustering routing protocol based on particle swarm optimization algorithm.

  15. An Accurate Link Correlation Estimator for Improving Wireless Protocol Performance

    PubMed Central

    Zhao, Zhiwei; Xu, Xianghua; Dong, Wei; Bu, Jiajun

    2015-01-01

    Wireless link correlation has shown significant impact on the performance of various sensor network protocols. Many works have been devoted to exploiting link correlation for protocol improvements. However, the effectiveness of these designs heavily relies on the accuracy of link correlation measurement. In this paper, we investigate state-of-the-art link correlation measurement and analyze the limitations of existing works. We then propose a novel lightweight and accurate link correlation estimation (LACE) approach based on the reasoning of link correlation formation. LACE combines both long-term and short-term link behaviors for link correlation estimation. We implement LACE as a stand-alone interface in TinyOS and incorporate it into both routing and flooding protocols. Simulation and testbed results show that LACE: (1) achieves more accurate and lightweight link correlation measurements than the state-of-the-art work; and (2) greatly improves the performance of protocols exploiting link correlation. PMID:25686314

  16. Evaluation of a discharge education protocol for pediatric patients with gastrostomy tubes.

    PubMed

    Schweitzer, Michelle; Aucoin, Julia; Docherty, Sharron L; Rice, Henry E; Thompson, Julie; Sullivan, Dori Taylor

    2014-01-01

    To evaluate the impact of a preprocedure education protocol for children who receive a gastrostomy tube (GT). A preintervention-postintervention design, using surveys and comparison between preprotocol and postprotocol cohorts, was used to evaluate the effect of implementation of a standardized GT education protocol with 26 subjects on caregiver, patient, and provider outcomes. The use of a preprocedure education protocol resulted in improved patient outcomes and increased caregiver knowledge and confidence and was considered a positive change by the providers. Often education is a forgotten part of a medical procedure, and the importance of education is typically only recognized after an adverse event occurs. Establishing a standardized evidence-based education protocol for GT care improves overall care and satisfaction. Use of a systematic and family-centered interdisciplinary approach markedly improves patient care. Copyright © 2014 National Association of Pediatric Nurse Practitioners. Published by Mosby, Inc. All rights reserved.

  17. Do different maxillary expansion appliances influence the outcomes of the treatment?

    PubMed

    Algharbi, Muteb; Bazargani, Farhan; Dimberg, Lillemor

    2018-01-23

    There is no consensus in the literature regarding which rapid maxillary expansion (RME) design or activation rate benefits the patients the most. Therefore, the primary aim of this systematic review was to see whether there is a difference in the skeletal and dentoalveolar effects of different RME appliances in children and growing adolescents. The secondary aim was to see whether these effects are different when using different activation protocols for these appliances. The search was done in three databases (PubMed, Cochrane Library, and Web of Science). The following inclusion criteria were used: randomized controlled trial, prospective controlled studies, 15 or more patients in each study, human subjects up to 18 years of age, and RME effects had to be assessed by computed tomography/cone beam computed tomography. Quality of the methodology was classified according to the Grading of Recommendations Assessment, Development and Evaluation (GRADE) guidelines as high, moderate, or low. The search resulted in 145 titles and abstracts; 109 of them were excluded based on pre-established criteria. Thirty-six full-text articles were assessed for eligibility and 18 of which satisfied the inclusion criteria. Finally, seven articles were deemed eligible for full inclusion and revealed that all appliances and protocols showed significant expansion in the mid-palatal suture. No evidence was found for the cause of dental tipping. In this systematic review, having different age groups in each study and using different anatomical landmarks and outcome measures for assessing the skeletal and dental effects made it difficult to conduct a meta-analysis. There is moderate evidence that all designs produce significant expansion at the mid-palatal suture. However, lack of studies comparing appliances and protocols has been found. Finally, no evidence-based conclusions could be drawn about the appliance effect on teeth tipping. No appliance appears to be superior when it comes to expansion in the mid-palatal suture. Therefore, the tooth-borne appliance might be preferable until further high-quality studies conclude otherwise. The project was funded through the Department of Orthodontics, Postgraduate Dental Education Center, Region Örebro County, Örebro, Sweden. This systematic review was not registered in any external databases. © The Author 2017. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com

  18. The Application of Timing in Therapy of Children and Adults with Language Disorders

    PubMed Central

    Szelag, Elzbieta; Dacewicz, Anna; Szymaszek, Aneta; Wolak, Tomasz; Senderski, Andrzej; Domitrz, Izabela; Oron, Anna

    2015-01-01

    A number of evidence revealed a link between temporal information processing (TIP) and language. Both literature data and results of our studies indicated an overlapping of deficient TIP and disordered language, pointing to the existence of an association between these two functions. On this background the new approach is to apply such knowledge in therapy of patients suffering from language disorders. In two studies we asked the following questions: (1) can the temporal training reduce language deficits in aphasic patients (Study 1) or in children with specific language impairment (SLI, Study 2)? (2) can such training ameliorate also the other cognitive functions? Each of these studies employed pre-training assessment, training application, post-training and follow-up assessment. In Study 1 we tested 28 patients suffering from post-stroke aphasia. They were assigned either to the temporal training (Group A, n = 15) in milliseconds range, or to the non-temporal training (Group B, n = 13). Following the training we found only in Group A improved TIP, accompanied by a transfer of improvement to language and working memory functions. In Study 2 we tested 32 children aged from 5 to 8 years, affected by SLI who were classified into the temporal training (Group A, n = 17) or non-temporal training (Group B, n = 15). Group A underwent the multileveled audio-visual computer training Dr. Neuronowski®, recently developed in our laboratory. Group B performed the computer speech therapy exercises extended by playing computer games. Similarly as in Study 1, in Group A we found significant improvements of TIP, auditory comprehension and working memory. These results indicated benefits of temporal training for amelioration of language and other cognitive functions in both aphasic patients and children with SLI. The novel powerful therapy tools provide evidence for future promising clinical applications. PMID:26617547

  19. The impact of the Family Communication Coordinator (FCC) Protocol on the role stress of hospital chaplains.

    PubMed

    Dodd-McCue, Diane; Tartaglia, Alexander

    2005-01-01

    The Family Communication Coordinator (FCC) Protocol was implemented to provide early family intervention and to facilitate effective communications during potential organ donation cases. Previous studies found the Protocol associated with improved donor outcome measures and with reduced role stress for ICU nurses caring for potential donors. The present study examines the impact of the Protocol on the perceived role stress of hospital chaplains serving as FCCs. All hospital chaplains serving as FCCs at an academic teaching hospital were surveyed. Their perceptions of job dimensions, role stress, job satisfaction, and commitment were measured; interviews and secondary data supplemented the surveys. The findings demonstrate that the FCC Protocol is associated with improved role stress, specifically role ambiguity and role conflict, among hospital chaplains serving as FCCs. Additionally, the findings suggest that satisfaction with the Protocol may be associated with experience with the Protocol.

  20. Electrospray ionization from nanopipette emitters with tip diameters of less than 100 nm.

    PubMed

    Yuill, Elizabeth M; Sa, Niya; Ray, Steven J; Hieftje, Gary M; Baker, Lane A

    2013-09-17

    Work presented here demonstrates application of nanopipettes pulled to orifice diameters of less than 100 nm as electrospray ionization emitters for mass spectrometry. Mass spectrometric analysis of a series of peptides and proteins electrosprayed from pulled-quartz capillary nanopipette emitters with internal diameters ranging from 37 to 70 nm is detailed. Overall, the use of nanopipette emitters causes a shift toward the production of ions of higher charge states and leads to a reduction in width of charge-state distribution as compared to typical nanospray conditions. Further, nanopipettes show improved S/N and the same signal precision as typical nanospray, despite the much smaller dimensions. As characterized by SEM images acquired before and after spray, nanopipettes are shown to be robust under conditions employed. Analytical calculations and numerical simulations are used to calculate the electric field at the emitter tip, which can be significant for the small diameter tips used.

  1. Tip/tilt optimizations for polynomial apodized vortex coronagraphs on obscured telescope pupils

    NASA Astrophysics Data System (ADS)

    Fogarty, Kevin; Pueyo, Laurent; Mazoyer, Johan; N'Diaye, Mamadou

    2017-09-01

    Obstructions due to large secondary mirrors, primary mirror segmentation, and secondary mirror support struts all introduce diffraction artifacts that limit the performance offered by coronagraphs. However, just as vortex coronagraphs provides theoretically ideal cancellation of on-axis starlight for clear apertures, the Polynomial Apodized Vortex Coronagraph (PAVC) completely blocks on-axis light for apertures with central obscurations, and delivers off-axis throughput that improves as the topological charge of the vortex increases. We examine the sensitivity of PAVC designs to tip/tilt aberrations and stellar angular size, and discuss methods for mitigating these effects. By imposing additional constraints on the pupil plane apodization, we decrease the sensitivity of the PAVC to the small positional shifts of the on-axis source induced by either tip/tilt or stellar angular size; providing a route to overcoming an important hurdle facing the performance of vortex coronagraphs on telescopes with complicated pupils.

  2. Hyperspectral imaging for detection of black tip damage in wheat kernels

    NASA Astrophysics Data System (ADS)

    Delwiche, Stephen R.; Yang, I.-Chang; Kim, Moon S.

    2009-05-01

    A feasibility study was conducted on the use of hyperspectral imaging to differentiate sound wheat kernels from those with the fungal condition called black point or black tip. Individual kernels of hard red spring wheat were loaded in indented slots on a blackened machined aluminum plate. Damage conditions, determined by official (USDA) inspection, were either sound (no damage) or damaged by the black tip condition alone. Hyperspectral imaging was separately performed under modes of reflectance from white light illumination and fluorescence from UV light (~380 nm) illumination. By cursory inspection of wavelength images, one fluorescence wavelength (531 nm) was selected for image processing and classification analysis. Results indicated that with this one wavelength alone, classification accuracy can be as high as 95% when kernels are oriented with their dorsal side toward the camera. It is suggested that improvement in classification can be made through the inclusion of multiple wavelength images.

  3. A randomized wait-list controlled analysis of the implementation integrity of team-initiated problem solving processes.

    PubMed

    Newton, J Stephen; Horner, Robert H; Algozzine, Bob; Todd, Anne W; Algozzine, Kate

    2012-08-01

    Members of Positive Behavior Interventions and Supports (PBIS) teams from 34 elementary schools participated in a Team-Initiated Problem Solving (TIPS) Workshop and follow-up technical assistance. Within the context of a randomized wait-list controlled trial, team members who were the first recipients of the TIPS intervention demonstrated greater implementation integrity in using the problem-solving processes during their team meetings than did members of PBIS Teams in the Wait-List Control group. The success of TIPS at improving implementation integrity of the problem-solving processes is encouraging and suggests the value of conducting additional research focused on determining whether there is a functional relation between use of these problem-solving processes and actual resolution of targeted student academic and social problems. Copyright © 2012 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  4. Field ionization characteristics of an ion source array for neutron generators

    NASA Astrophysics Data System (ADS)

    Bargsten Johnson, B.; Schwoebel, P. R.; Resnick, P. J.; Holland, C. E.; Hertz, K. L.; Chichester, D. L.

    2013-11-01

    A new deuterium ion source is being developed to improve the performance of existing compact neutron generators. The ion source is a microfabricated array of metal tips with an integrated gate (i.e., grid) and produces deuterium ions by field ionizing (or field desorbing) a supply of deuterium gas. Deuterium field ion currents from arrays at source temperatures of 77 K and 293 K are studied. Ion currents from single etched-wire tips operating under the same conditions are used to help understand array results. I-F characteristics of the arrays were found to follow trends similar to those of the better understood single etched-wire tip results; however, the fields achieved by the arrays are limited by electrical breakdown of the structure. Neutron production by field ionization at 293 K was demonstrated for the first time from microfabricated array structures with integrated gates.

  5. Chip-on-the-tip ultra-compact flexible endoscopic epifluorescence video-microscope for in-vivo imaging in medical and biomedical fields

    NASA Astrophysics Data System (ADS)

    Matz, Gregor; Messerschmidt, Bernhard; Göbel, Werner; Filser, Severin; Betz, Christian; Kunze, Marcel; Flaemig, Sven; Ehrhardt, André; Irion, Klaus-Martin; Herms, Jochen; Gross, Herbert

    2017-02-01

    We demonstrate a flexible stand-alone, minimally invasive video-endomicroscope with an outer diameter of 1.6 mm and a length of the rigid tip of 6.7 mm that enables surgeons and biologists to image hardly accessible regions in-vivo in epifluorescence mode. The 60 mg light device improves state-of-the-art objectives by a double deflection approach using a side-fire fiber in combination with spherical microlenses, GRIN-lenses with a specific adapted gradient index profile and an extremely miniaturized chip-on-the-tip camera to achieve an excellent imaging quality. A high NA of 0.7 enables the observation of subcellular features within the entire field of view with a diameter of 183 μm, assure a bright and high-contrast image and promise a good overview during the intervention. Ex-vivo measurements of biological samples confirmed the functionality of the probe.

  6. A prediction of 3-D viscous flow and performance of the NASA Low-Speed Centrifugal Compressor

    NASA Technical Reports Server (NTRS)

    Moore, John; Moore, Joan G.

    1990-01-01

    A prediction of the three-dimensional turbulent flow in the NASA Low-Speed Centrifugal Compressor Impeller has been made. The calculation was made for the compressor design conditions with the specified uniform tip clearance gap. The predicted performance is significantly worse than that predicted in the NASA design study. This is explained by the high tip leakage flow in the present calculation and by the different model adopted for tip leakage flow mixing. The calculation gives an accumulation of high losses in the shroud/pressure-side quadrant near the exit of the impeller. It also predicts a region of meridional backflow near the shroud wall. Both of these flow features should be extensive enough in the NASA impeller to allow detailed flow measurements, leading to improved flow modeling. Recommendations are made for future flow studies in the NASA impeller.

  7. A prediction of 3-D viscous flow and performance of the NASA low-speed centrifugal compressor

    NASA Technical Reports Server (NTRS)

    Moore, John; Moore, Joan G.

    1989-01-01

    A prediction of the 3-D turbulent flow in the NASA Low-Speed Centrifugal Compressor Impeller has been made. The calculation was made for the compressor design conditions with the specified uniform tip clearance gap. The predicted performance is significantly worse than that predicted in the NASA design study. This is explained by the high tip leakage flow in the present calculation and by the different model adopted for tip leakage flow mixing. The calculation gives an accumulation for high losses in the shroud/pressure-side quadrant near the exit of the impeller. It also predicts a region of meridional backflow near the shroud wall. Both of these flow features should be extensive enough in the NASA impeller to allow detailed flow measurements, leading to improved flow modelling. Recommendations are made for future flow studies in the NASA impeller.

  8. Bioinspired Composite Microfibers for Skin Adhesion and Signal Amplification of Wearable Sensors.

    PubMed

    Drotlef, Dirk-M; Amjadi, Morteza; Yunusa, Muhammad; Sitti, Metin

    2017-07-01

    A facile approach is proposed for superior conformation and adhesion of wearable sensors to dry and wet skin. Bioinspired skin-adhesive films are composed of elastomeric microfibers decorated with conformal and mushroom-shaped vinylsiloxane tips. Strong skin adhesion is achieved by crosslinking the viscous vinylsiloxane tips directly on the skin surface. Furthermore, composite microfibrillar adhesive films possess a high adhesion strength of 18 kPa due to the excellent shape adaptation of the vinylsiloxane tips to the multiscale roughness of the skin. As a utility of the skin-adhesive films in wearable-device applications, they are integrated with wearable strain sensors for respiratory and heart-rate monitoring. The signal-to-noise ratio of the strain sensor is significantly improved to 59.7 because of the considerable signal amplification of microfibrillar skin-adhesive films. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. A possible explanation for the present difference between linear noise theory and experimental data for supersonic helical tip speed propellers

    NASA Technical Reports Server (NTRS)

    Dittmar, J. H.

    1983-01-01

    High speed turboprops are attractive candidates for future aircraft because of their high propulsive efficiency. However, the noise of their propellers may create a cabin environment problem for the aircraft powered by these propellers. The noise of some propeller models was measured, and predictions of the noise using a method based on the Ffowcs Williams-Hawkins equation were made. The predictions and data agree well at lower helical tip Mach numbers but deviate above Mach 1.0. Some possible reasons why the theory does not predict the data and focuses on improvement of the aerodynamic inputs as the most likely remedy are investigated. In particular, it is proposed that an increase in the drag and a decrease in the lift near the tip of the blade where the majority of the noise is generated, is warranted in the input to the theory.

  10. A Visualization Study of Secondary Flows in Cascades

    NASA Technical Reports Server (NTRS)

    Herzig, Howard Z; Hansen, Arthur G; Costello, George R

    1954-01-01

    Flow-visualization techniques are employed to ascertain the streamline patterns of the nonpotential secondary flows in the boundary layers of cascades, and thereby to provide a basis for more extended analyses in turbomachines. The three-dimensional deflection of the end-wall boundary layer results in the formation of a vortex within each cascade passage. The size and tightness of the vortex generated depend upon the main-flow turning in the cascade passage. Once formed, a vortex resists turning in subsequent blade rows, with consequent unfavorable angles of attack and possible flow disturbances on the pressure surfaces of subsequent blade rows when the vortices impinge on these surfaces. Two major tip-clearance effects are observed, the formation of a tip-clearance vortex and the scraping effect of a blade with relative motion past the wall boundary layer. The flow patterns indicate methods for improving the blade tip-loading characteristics of compressors and of low- and high-speed turbulence.

  11. Integrally formed radio frequency quadrupole

    DOEpatents

    Abbott, Steven R.

    1989-01-01

    An improved radio frequency quadrupole (10) is provided having an elongate housing (11) with an elongate central axis (12) and top, bottom and two side walls (13a-d) symmetrically disposed about the axis, and vanes (14a-d) formed integrally with the walls (13a-d), the vanes (14a-d) each having a cross-section at right angles to the central axis (12) which tapers inwardly toward the axis to form electrode tips (15a-d) spaced from each other by predetermined distances. Each of the four walls (13a-d), and the vanes (14a-d) integral therewith, is a separate structural element having a central lengthwise plane (16) passing through the tip of the vane, the walls (13a-d) having flat mounting surfaces (17, 18) at right angles to and parallel to the control plane (16), respectively, which are butted together to position the walls and vane tips relative to each other.

  12. Energy Efficient Medium Access Control Protocol for Clustered Wireless Sensor Networks with Adaptive Cross-Layer Scheduling.

    PubMed

    Sefuba, Maria; Walingo, Tom; Takawira, Fambirai

    2015-09-18

    This paper presents an Energy Efficient Medium Access Control (MAC) protocol for clustered wireless sensor networks that aims to improve energy efficiency and delay performance. The proposed protocol employs an adaptive cross-layer intra-cluster scheduling and an inter-cluster relay selection diversity. The scheduling is based on available data packets and remaining energy level of the source node (SN). This helps to minimize idle listening on nodes without data to transmit as well as reducing control packet overhead. The relay selection diversity is carried out between clusters, by the cluster head (CH), and the base station (BS). The diversity helps to improve network reliability and prolong the network lifetime. Relay selection is determined based on the communication distance, the remaining energy and the channel quality indicator (CQI) for the relay cluster head (RCH). An analytical framework for energy consumption and transmission delay for the proposed MAC protocol is presented in this work. The performance of the proposed MAC protocol is evaluated based on transmission delay, energy consumption, and network lifetime. The results obtained indicate that the proposed MAC protocol provides improved performance than traditional cluster based MAC protocols.

  13. Energy Efficient Medium Access Control Protocol for Clustered Wireless Sensor Networks with Adaptive Cross-Layer Scheduling

    PubMed Central

    Sefuba, Maria; Walingo, Tom; Takawira, Fambirai

    2015-01-01

    This paper presents an Energy Efficient Medium Access Control (MAC) protocol for clustered wireless sensor networks that aims to improve energy efficiency and delay performance. The proposed protocol employs an adaptive cross-layer intra-cluster scheduling and an inter-cluster relay selection diversity. The scheduling is based on available data packets and remaining energy level of the source node (SN). This helps to minimize idle listening on nodes without data to transmit as well as reducing control packet overhead. The relay selection diversity is carried out between clusters, by the cluster head (CH), and the base station (BS). The diversity helps to improve network reliability and prolong the network lifetime. Relay selection is determined based on the communication distance, the remaining energy and the channel quality indicator (CQI) for the relay cluster head (RCH). An analytical framework for energy consumption and transmission delay for the proposed MAC protocol is presented in this work. The performance of the proposed MAC protocol is evaluated based on transmission delay, energy consumption, and network lifetime. The results obtained indicate that the proposed MAC protocol provides improved performance than traditional cluster based MAC protocols. PMID:26393608

  14. Moving Every Child Ahead: The Big6 Success Strategy.

    ERIC Educational Resources Information Center

    Berkowitz, Bob; Serim, Ferdi

    2002-01-01

    Explains the Big6 approach to teaching information skills and describes its use in a high school social studies class to improve student test scores, teach them how to learn, and improve the teachers' skills. Highlights include the balance between content and process, formative and summative evaluation, assignment organizers, and study tips. (LRW)

  15. Air Quality Conformity Determination Of the Constrained Long Range Plan And The FY99-2004 Transportation Improvement Program For The Washington Metropolitan Region

    DOT National Transportation Integrated Search

    1998-07-15

    This report documents the assessment of the Constrained Long Range Plan (CLRP) and the FY99-2004 Transportation Improvement Program (TIP) with respect to air quality conformity requirements under the 1990 Clean Air Act Amendments. The assessment used...

  16. After-School Toolkit: Tips, Techniques and Templates for Improving Program Quality

    ERIC Educational Resources Information Center

    Gutierrez, Nora; Bradshaw, Molly; Furano, Kathryn

    2008-01-01

    This toolkit offers program managers a hands-on guide for implementing quality programming in the after-school hours. The kit includes tools and techniques that increased the quality of literacy programming and helped improve student reading gains in the Communities Organizing Resources to Advance Learning (CORAL) initiative of The James Irvine…

  17. The Myth, the Truth, the NASA IRB

    NASA Technical Reports Server (NTRS)

    Covington, M. D.; Flores, M. P.; Neutzler, V. P.; Schlegel, T. T.; Platts, S. H.; Lioyd, C. W.

    2017-01-01

    The purpose of the NASA Institutional Review Board (IRB) is to review research activities involving human subjects to ensure that ethical standards for the care and protection of human subjects have been met and research activities are in compliance with all pertinent federal, state and local regulations as well as NASA policies. NASA IRB's primary role is the protection of human subjects in research studies. Protection of human subjects is the shared responsibility of NASA, the IRB, and the scientific investigators. Science investigators who plan to conduct NASA-funded human research involving NASA investigators, facilities, or funds must submit and coordinate their research studies for review and approval by the NASA IRB prior to initiation. The IRB has the authority to approve, require changes in, or disapprove research involving human subjects. Better knowledge of the NASA IRB policies, procedures and guidelines should help facilitate research protocol applications and approvals. In this presentation, the myths and truths of NASA IRB policies and procedures will be discussed. We will focus on the policies that guide a protocol through the NASA IRB and the procedures that principal investigators must take to obtain required IRB approvals for their research studies. In addition, tips to help ensure a more efficient IRB review will be provided. By understanding the requirements and processes, investigators will be able to more efficiently prepare their protocols and obtain the required NASA IRB approval in a timely manner.

  18. Remote population-based intervention for disruptive behavior at age four: study protocol for a randomized trial of Internet-assisted parent training (Strongest Families Finland-Canada).

    PubMed

    McGrath, Patrick J; Sourander, Andre; Lingley-Pottie, Patricia; Ristkari, Terja; Cunningham, Charles; Huttunen, Jukka; Filbert, Katharine; Aromaa, Minna; Corkum, Penny; Hinkka-Yli-Salomäki, Susanna; Kinnunen, Malin; Lampi, Katja; Penttinen, Anne; Sinokki, Atte; Unruh, Anita; Vuorio, Jenni; Watters, Carolyn

    2013-10-21

    Oppositional Defiant Disorder (ODD) is characterized by angry and noncompliant behaviour. It is the most common disruptive behaviour disorder (DBD), with prevalence estimates of 6-9% for preschoolers and is closely linked to several long-term difficulties, including disorders of conduct, mood, anxiety, impulse-control, and substance abuse. ODD in children is related to parental depression, family dysfunction, and impairments in parental work performance. Children displaying early DBDs exhibit more symptoms of greater severity, more frequent offences, and commit more serious crimes later in life. The goal of the Strongest Families Finland Canada (SFFC) Smart Website intervention research program is to develop and evaluate an affordable, accessible, effective secondary prevention parent training program for disruptive behaviour in preschoolers to prevent the negative sequelae of ODD. Strongest Families is an 11-session program with two booster sessions that focuses on teaching skills to: strengthen parent-child relationships; reinforce positive behaviour; reduce conflict; manage daily transitions; plan for potentially problematic situations; promote emotional regulation and pro-social behaviour and decrease antisocial behaviour. This protocol paper describes an ongoing population-based randomized controlled trial (RCT) of high-risk 4 year-olds attending well-child clinics in Turku, Finland and environs to examine the effectiveness of the Strongest Families Smart Website intervention compared to an Education Control condition. Randomization consists of a 1:1 ratio for intervention versus the education group, stratified by the child's sex. The participants randomized to the intervention group receive access to the Strongest Families Smart Website and weekly telephone coaching sessions. The participants randomized to the Education Control condition receive access to a static website with parenting tips. Children are followed using parental and daycare teacher measures at 6 and 12 months after randomization. The Strongest Families Smart Website intervention is hypothesized to improve parenting skills, reduce child disruptive behaviour, reduce parental distress and improve family functioning. These results will likely inform subsequent investigations, public policy, and early treatment of childhood disruptive behaviour problems. ClinicalTrials.gov # NCT01750996.

  19. Remote population-based intervention for disruptive behavior at age four: study protocol for a randomized trial of Internet-assisted parent training (Strongest Families Finland-Canada)

    PubMed Central

    2013-01-01

    Background Oppositional Defiant Disorder (ODD) is characterized by angry and noncompliant behaviour. It is the most common disruptive behaviour disorder (DBD), with prevalence estimates of 6-9% for preschoolers and is closely linked to several long-term difficulties, including disorders of conduct, mood, anxiety, impulse-control, and substance abuse. ODD in children is related to parental depression, family dysfunction, and impairments in parental work performance. Children displaying early DBDs exhibit more symptoms of greater severity, more frequent offences, and commit more serious crimes later in life. The goal of the Strongest Families™ Finland Canada (SFFC) Smart Website intervention research program is to develop and evaluate an affordable, accessible, effective secondary prevention parent training program for disruptive behaviour in preschoolers to prevent the negative sequelae of ODD. Strongest Families is an 11-session program with two booster sessions that focuses on teaching skills to: strengthen parent–child relationships; reinforce positive behaviour; reduce conflict; manage daily transitions; plan for potentially problematic situations; promote emotional regulation and pro-social behaviour and decrease antisocial behaviour. Methods/design This protocol paper describes an ongoing population-based randomized controlled trial (RCT) of high-risk 4 year-olds attending well-child clinics in Turku, Finland and environs to examine the effectiveness of the Strongest Families Smart Website intervention compared to an Education Control condition. Randomization consists of a 1:1 ratio for intervention versus the education group, stratified by the child’s sex. The participants randomized to the intervention group receive access to the Strongest Families Smart Website and weekly telephone coaching sessions. The participants randomized to the Education Control condition receive access to a static website with parenting tips. Children are followed using parental and daycare teacher measures at 6 and 12 months after randomization. Discussion The Strongest Families Smart Website intervention is hypothesized to improve parenting skills, reduce child disruptive behaviour, reduce parental distress and improve family functioning. These results will likely inform subsequent investigations, public policy, and early treatment of childhood disruptive behaviour problems. Trial registration ClinicalTrials.gov # NCT01750996 PMID:24139323

  20. Effectiveness of User- and Expert-Driven Web-based Hypertension Programs: an RCT.

    PubMed

    Liu, Sam; Brooks, Dina; Thomas, Scott G; Eysenbach, Gunther; Nolan, Robert P

    2018-04-01

    The effectiveness of self-guided Internet-based lifestyle counseling (e-counseling) varies, depending on treatment protocol. Two dominant procedures in e-counseling are expert- and user-driven. The influence of these procedures on hypertension management remains unclear. The objective was to assess whether blood pressure improved with expert-driven or user-driven e-counseling over control intervention in patients with hypertension over a 4-month period. This study used a three-parallel group, double-blind randomized controlled design. In Toronto, Canada, 128 participants (aged 35-74 years) with hypertension were recruited. Participants were recruited using online and poster advertisements. Data collection took place between June 2012 and June 2014. Data were analyzed from October 2014 to December 2016. Controls received a weekly e-mail newsletter regarding hypertension management. The expert-driven group was prescribed a weekly exercise and diet plan (e.g., increase 1,000 steps/day this week). The user-driven group received weekly e-mail, which allowed participants to choose their intervention goals (e.g., [1] feel more confident to change my lifestyle, or [2] self-help tips for exercise or a heart healthy diet). Primary outcome was systolic blood pressure measured at baseline and 4-month follow-up. Secondary outcomes included cholesterol, 10-year Framingham cardiovascular risk, daily steps, and dietary habits. Expert-driven groups showed a greater systolic blood pressure decrease than controls at follow-up (expert-driven versus control: -7.5 mmHg, 95% CI= -12.5, -2.6, p=0.01). Systolic blood pressure reduction did not significantly differ between user- and expert-driven. Expert-driven compared with controls also showed a significant improvement in pulse pressure, cholesterol, and Framingham risk score. The expert-driven intervention was significantly more effective than both user-driven and control groups in increasing daily steps and fruit intake. It may be advisable to incorporate an expert-driven e-counseling protocol in order to accommodate participants with greater motivation to change their lifestyle behaviors, but more studies are needed. This study is registered at www.clinicaltrials.gov NCT03111836. Copyright © 2018 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

Top