Rabelo, Michelle; Nunes, Guilherme S; da Costa Amante, Natália Menezes; de Noronha, Marcos; Fachin-Martins, Emerson
2016-02-01
Muscle weakness is the main cause of motor impairment among stroke survivors and is associated with reduced peak muscle torque. To systematically investigate and organize the evidence of the reliability of muscle strength evaluation measures in post-stroke survivors with chronic hemiparesis. Two assessors independently searched four electronic databases in January 2014 (Medline, Scielo, CINAHL, Embase). Inclusion criteria comprised studies on reliability on muscle strength assessment in adult post-stroke patients with chronic hemiparesis. We extracted outcomes from included studies about reliability data, measured by intraclass correlation coefficient (ICC) and/or similar. The meta-analyses were conducted only with isokinetic data. Of 450 articles, eight articles were included for this review. After quality analysis, two studies were considered of high quality. Five different joints were analyzed within the included studies (knee, hip, ankle, shoulder, and elbow). Their reliability results varying from low to very high reliability (ICCs from 0.48 to 0.99). Results of meta-analysis for knee extension varying from high to very high reliability (pooled ICCs from 0.89 to 0.97), for knee flexion varying from high to very high reliability (pooled ICCs from 0.84 to 0.91) and for ankle plantar flexion showed high reliability (pooled ICC = 0.85). Objective muscle strength assessment can be reliably used in lower and upper extremities in post-stroke patients with chronic hemiparesis.
Validity and Reliability of the Academic Resilience Scale in Turkish High School
ERIC Educational Resources Information Center
Kapikiran, Sahin
2012-01-01
The present study aims to determine the validity and reliability of the academic resilience scale in Turkish high school. The participances of the study includes 378 high school students in total (192 female and 186 male). A set of analyses were conducted in order to determine the validity and reliability of the study. Firstly, both exploratory…
On-clip high frequency reliability and failure test structures
Snyder, Eric S.; Campbell, David V.
1997-01-01
Self-stressing test structures for realistic high frequency reliability characterizations. An on-chip high frequency oscillator, controlled by DC signals from off-chip, provides a range of high frequency pulses to test structures. The test structures provide information with regard to a variety of reliability failure mechanisms, including hot-carriers, electromigration, and oxide breakdown. The system is normally integrated at the wafer level to predict the failure mechanisms of the production integrated circuits on the same wafer.
On-clip high frequency reliability and failure test structures
Snyder, E.S.; Campbell, D.V.
1997-04-29
Self-stressing test structures for realistic high frequency reliability characterizations. An on-chip high frequency oscillator, controlled by DC signals from off-chip, provides a range of high frequency pulses to test structures. The test structures provide information with regard to a variety of reliability failure mechanisms, including hot-carriers, electromigration, and oxide breakdown. The system is normally integrated at the wafer level to predict the failure mechanisms of the production integrated circuits on the same wafer. 22 figs.
Sexual behaviors among club drug users: prevalence and reliability
Shacham, Enbal; Cottler, Linda B.
2013-01-01
HIV prevention efforts require a focus on reducing high risk sexual behavior. Because these are self-reported, assessments that reduce memory bias and improve elicitation of data are needed. As part of a multi-site psychometric study of club drug use, abuse, and dependence, data were collected with a test-retest design that measured the reliability of the Washington University Risk Behavior Assessment for Club Drugs (WU-RBA-CD). Reliability was assessed separately by sex via kappa coefficients and intraclass correlation coefficients (ICC); z tests compared coefficients by sex. A total of 603 participants were interviewed by independent assessors with 5 days in between interviews. Reliability for all 51 items of the sexual activity section of the WU-RBA-CD ranged from .23 to 1.00; 71% (n = 36) of items resulted in moderate to high reliability (.55–1.00). Number of lifetime sex partners was consistently reported for same-sex partners for both men and women and opposite-sex partners. Items with high reliability included reporting ever being under the influence of ecstasy (.87) or GHB (.87) while having sex. Items with lower reliability included those that queried the determinants of condom use (.45–.82) and about behaviors and attitudes experienced while using drugs (.23–.87). Very few sex differences were revealed in the reliability of reported sexual activities. Overall, the WU-RBA-CD performed with fairly high reliability rates. Assessing situations of when, how, and why individuals use condoms may offer the clearest evaluation of determinants of sexual behaviors, yet those items are not as reliable. PMID:19757011
High-reliability gas-turbine combined-cycle development program: Phase II. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hecht, K.G.; Sanderson, R.A.; Smith, M.J.
This three-volume report presents the results of Phase II of the multiphase EPRI-sponsored High-Reliability Gas Turbine Combined-Cycle Development Program whose goal is to achieve a highly reliable gas turbine combined-cycle power plant, available by the mid-1980s, which would be an economically attractive baseload generation alternative for the electric utility industry. The Phase II program objective was to prepare the preliminary design of this power plant. This volume presents information of the reliability, availability, and maintainability (RAM) analysis of a representative plant and the preliminary design of the gas turbine, the gas turbine ancillaries, and the balance of plant including themore » steam turbine generator. To achieve the program goals, a gas turbine was incorporated which combined proven reliability characteristics with improved performance features. This gas turbine, designated the V84.3, is the result of a cooperative effort between Kraftwerk Union AG and United Technologies Corporation. Gas turbines of similar design operating in Europe under baseload conditions have demonstrated mean time between failures in excess of 40,000 hours. The reliability characteristics of the gas turbine ancillaries and balance-of-plant equipment were improved through system simplification and component redundancy and by selection of component with inherent high reliability. A digital control system was included with logic, communications, sensor redundancy, and mandual backup. An independent condition monitoring and diagnostic system was also included. Program results provide the preliminary design of a gas turbine combined-cycle baseload power plant. This power plant has a predicted mean time between failure of nearly twice the 3000-hour EPRI goal. The cost of added reliability features is offset by improved performance, which results in a comparable specific cost and an 8% lower cost of electricity compared to present market offerings.« less
Loeding, B L; Greenan, J P
1998-12-01
The study examined the validity and reliability of four assessments, with three instruments per domain. Domains included generalizable mathematics, communication, interpersonal relations, and reasoning skills. Participants were deaf, legally blind, or visually impaired students enrolled in vocational classes at residential secondary schools. The researchers estimated the internal consistency reliability, test-retest reliability, and construct validity correlations of three subinstruments: student self-ratings, teacher ratings, and performance assessments. The data suggest that these instruments are highly internally consistent measures of generalizable vocational skills. Four performance assessments have high-to-moderate test-retest reliability estimates, and were generally considered to possess acceptable validity and reliability.
Design of high reliability organizations in health care.
Carroll, J S; Rudolph, J W
2006-12-01
To improve safety performance, many healthcare organizations have sought to emulate high reliability organizations from industries such as nuclear power, chemical processing, and military operations. We outline high reliability design principles for healthcare organizations including both the formal structures and the informal practices that complement those structures. A stage model of organizational structures and practices, moving from local autonomy to formal controls to open inquiry to deep self-understanding, is used to illustrate typical challenges and design possibilities at each stage. We suggest how organizations can use the concepts and examples presented to increase their capacity to self-design for safety and reliability.
One-year test-retest reliability of intrinsic connectivity network fMRI in older adults
Guo, Cong C.; Kurth, Florian; Zhou, Juan; Mayer, Emeran A.; Eickhoff, Simon B; Kramer, Joel H.; Seeley, William W.
2014-01-01
“Resting-state” or task-free fMRI can assess intrinsic connectivity network (ICN) integrity in health and disease, suggesting a potential for use of these methods as disease-monitoring biomarkers. Numerous analytical options are available, including model-driven ROI-based correlation analysis and model-free, independent component analysis (ICA). High test-retest reliability will be a necessary feature of a successful ICN biomarker, yet available reliability data remains limited. Here, we examined ICN fMRI test-retest reliability in 24 healthy older subjects scanned roughly one year apart. We focused on the salience network, a disease-relevant ICN not previously subjected to reliability analysis. Most ICN analytical methods proved reliable (intraclass coefficients > 0.4) and could be further improved by wavelet analysis. Seed-based ROI correlation analysis showed high map-wise reliability, whereas graph theoretical measures and temporal concatenation group ICA produced the most reliable individual unit-wise outcomes. Including global signal regression in ROI-based correlation analyses reduced reliability. Our study provides a direct comparison between the most commonly used ICN fMRI methods and potential guidelines for measuring intrinsic connectivity in aging control and patient populations over time. PMID:22446491
Davenport, Paul B; Carter, Kimberly F; Echternach, Jeffrey M; Tuck, Christopher R
2018-02-01
High-reliability organizations (HROs) demonstrate unique and consistent characteristics, including operational sensitivity and control, situational awareness, hyperacute use of technology and data, and actionable process transformation. System complexity and reliance on information-based processes challenge healthcare organizations to replicate HRO processes. This article describes a healthcare organization's 3-year journey to achieve key HRO features to deliver high-quality, patient-centric care via an operations center powered by the principles of high-reliability data and software to impact patient throughput and flow.
Design of high reliability organizations in health care
Carroll, J S; Rudolph, J W
2006-01-01
To improve safety performance, many healthcare organizations have sought to emulate high reliability organizations from industries such as nuclear power, chemical processing, and military operations. We outline high reliability design principles for healthcare organizations including both the formal structures and the informal practices that complement those structures. A stage model of organizational structures and practices, moving from local autonomy to formal controls to open inquiry to deep self‐understanding, is used to illustrate typical challenges and design possibilities at each stage. We suggest how organizations can use the concepts and examples presented to increase their capacity to self‐design for safety and reliability. PMID:17142607
High-reliability gas-turbine combined-cycle development program: Phase II, Volume 3. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hecht, K.G.; Sanderson, R.A.; Smith, M.J.
This three-volume report presents the results of Phase II of the multiphase EPRI-sponsored High-Reliability Gas Turbine Combined-Cycle Development Program whose goal is to achieve a highly reliable gas turbine combined-cycle power plant, available by the mid-1980s, which would be an economically attractive baseload generation alternative for the electric utility industry. The Phase II program objective was to prepare the preliminary design of this power plant. The power plant was addressed in three areas: (1) the gas turbine, (2) the gas turbine ancillaries, and (3) the balance of plant including the steam turbine generator. To achieve the program goals, a gasmore » turbine was incorporated which combined proven reliability characteristics with improved performance features. This gas turbine, designated the V84.3, is the result of a cooperative effort between Kraftwerk Union AG and United Technologies Corporation. Gas turbines of similar design operating in Europe under baseload conditions have demonstrated mean time between failures in excess of 40,000. The reliability characteristics of the gas turbine ancillaries and balance-of-plant equipment were improved through system simplification and component redundancy and by selection of component with inherent high reliability. A digital control system was included with logic, communications, sensor redundancy, and manual backup. An independent condition monitoring and diagnostic system was also included. Program results provide the preliminary design of a gas turbine combined-cycle baseload power plant. This power plant has a predicted mean time between failure of nearly twice the 3000-h EPRI goal. The cost of added reliability features is offset by improved performance, which results in a comparable specific cost and an 8% lower cost of electricty compared to present market offerings.« less
Challenges Regarding IP Core Functional Reliability
NASA Technical Reports Server (NTRS)
Berg, Melanie D.; LaBel, Kenneth A.
2017-01-01
For many years, intellectual property (IP) cores have been incorporated into field programmable gate array (FPGA) and application specific integrated circuit (ASIC) design flows. However, the usage of large complex IP cores were limited within products that required a high level of reliability. This is no longer the case. IP core insertion has become mainstream including their use in highly reliable products. Due to limited visibility and control, challenges exist when using IP cores and subsequently compromise product reliability. We discuss challenges and suggest potential solutions to critical application IP insertion.
Establishing Inter- and Intrarater Reliability for High-Stakes Testing Using Simulation.
Kardong-Edgren, Suzan; Oermann, Marilyn H; Rizzolo, Mary Anne; Odom-Maryon, Tamara
This article reports one method to develop a standardized training method to establish the inter- and intrarater reliability of a group of raters for high-stakes testing. Simulation is used increasingly for high-stakes testing, but without research into the development of inter- and intrarater reliability for raters. Eleven raters were trained using a standardized methodology. Raters scored 28 student videos over a six-week period. Raters then rescored all videos over a two-day period to establish both intra- and interrater reliability. One rater demonstrated poor intrarater reliability; a second rater failed all students. Kappa statistics improved from the moderate to substantial agreement range with the exclusion of the two outlier raters' scores. There may be faculty who, for different reasons, should not be included in high-stakes testing evaluations. All faculty are content experts, but not all are expert evaluators.
Improving patient safety: patient-focused, high-reliability team training.
McKeon, Leslie M; Cunningham, Patricia D; Oswaks, Jill S Detty
2009-01-01
Healthcare systems are recognizing "human factor" flaws that result in adverse outcomes. Nurses work around system failures, although increasing healthcare complexity makes this harder to do without risk of error. Aviation and military organizations achieve ultrasafe outcomes through high-reliability practice. We describe how reliability principles were used to teach nurses to improve patient safety at the front line of care. Outcomes include safety-oriented, teamwork communication competency; reflections on safety culture and clinical leadership are discussed.
The Interplay of Surface Mount Solder Joint Quality and Reliability of Low Volume SMAs
NASA Technical Reports Server (NTRS)
Ghaffarian, R.
1997-01-01
Spacecraft electronics including those used at the Jet Propulsion Laboratory (JPL), demand production of highly reliable assemblies. JPL has recently completed an extensive study, funded by NASA's code Q, of the interplay between manufacturing defects and reliability of ball grid array (BGA) and surface mount electronic components.
McCurdy, M; Bellows, A; Deng, D; Leppert, M; Mahone, E; Pritchard, A
2015-01-01
Reliable and valid screening and assessment tools are necessary to identify children at risk for neurodevelopmental disabilities who may require additional services. This study evaluated the test-retest reliability of the Capute Scales in a high-risk sample, hypothesizing adequate reliability across 6- and 12-month intervals. Capute Scales scores (N = 66) were collected via retrospective chart review from a NICU follow-up clinic within a large urban medical center spanning three age-ranges: 12-18, 19-24, and 25-36 months. On average, participants were classified as very low birth weight and premature. Reliability of the Capute Scales was evaluated with intraclass correlation coefficients across length of test-retest interval, age at testing, and degree of neonatal complications. The Capute Scales demonstrated high reliability, regardless of length of test-retest interval (ranging from 6 to 14 months) or age of participant, for all index scores, including overall Developmental Quotient (DQ), language-based skill index (CLAMS) and nonverbal reasoning index (CAT). Linear regressions revealed that greater neonatal risk was related to poorer test-retest reliability; however, reliability coefficients remained strong. The Capute Scales afford clinicians a reliable and valid means of screening and assessing for neurodevelopmental delay within high-risk infant populations.
Reliability of Leg and Vertical Stiffness During High Speed Treadmill Running.
Pappas, Panagiotis; Dallas, Giorgos; Paradisis, Giorgos
2017-04-01
In research, the accurate and reliable measurement of leg and vertical stiffness could contribute to valid interpretations. The current study aimed at determining the intraparticipant variability (ie, intraday and interday reliabilities) of leg and vertical stiffness, as well as related parameters, during high speed treadmill running, using the "sine-wave" method. Thirty-one males ran on a treadmill at 6.67 m∙s -1 , and the contact and flight times were measured. To determine the intraday reliability, three 10-s running bouts with 10-min recovery were performed. In addition, to examine the interday reliability, three 10-s running bouts on 3 separate days with 48-h interbout intervals were performed. The reliability statistics included repeated-measure analysis of variance, average intertrial correlations, intraclass correlation coefficients (ICCs), Cronbach's α reliability coefficient, and the coefficient of variation (CV%). Both intraday and interday reliabilities were high for leg and vertical stiffness (ICC > 0.939 and CV < 4.3%), as well as related variables (ICC > 0.934 and CV < 3.9%). It was thus inferred that the measurements of leg and vertical stiffness, as well as the related parameters obtained using the "sine-wave" method during treadmill running at 6.67 m∙s -1 , were highly reliable, both within and across days.
NASA Technical Reports Server (NTRS)
Platt, M. E.; Lewis, E. E.; Boehm, F.
1991-01-01
A Monte Carlo Fortran computer program was developed that uses two variance reduction techniques for computing system reliability applicable to solving very large highly reliable fault-tolerant systems. The program is consistent with the hybrid automated reliability predictor (HARP) code which employs behavioral decomposition and complex fault-error handling models. This new capability is called MC-HARP which efficiently solves reliability models with non-constant failures rates (Weibull). Common mode failure modeling is also a specialty.
Survey of Software Assurance Techniques for Highly Reliable Systems
NASA Technical Reports Server (NTRS)
Nelson, Stacy
2004-01-01
This document provides a survey of software assurance techniques for highly reliable systems including a discussion of relevant safety standards for various industries in the United States and Europe, as well as examples of methods used during software development projects. It contains one section for each industry surveyed: Aerospace, Defense, Nuclear Power, Medical Devices and Transportation. Each section provides an overview of applicable standards and examples of a mission or software development project, software assurance techniques used and reliability achieved.
ERIC Educational Resources Information Center
Daniels, Vijay J.; Bordage, Georges; Gierl, Mark J.; Yudkowsky, Rachel
2014-01-01
Objective structured clinical examinations (OSCEs) are used worldwide for summative examinations but often lack acceptable reliability. Research has shown that reliability of scores increases if OSCE checklists for medical students include only clinically relevant items. Also, checklists are often missing evidence-based items that high-achieving…
Integrating Formal Methods and Testing 2002
NASA Technical Reports Server (NTRS)
Cukic, Bojan
2002-01-01
Traditionally, qualitative program verification methodologies and program testing are studied in separate research communities. None of them alone is powerful and practical enough to provide sufficient confidence in ultra-high reliability assessment when used exclusively. Significant advances can be made by accounting not only tho formal verification and program testing. but also the impact of many other standard V&V techniques, in a unified software reliability assessment framework. The first year of this research resulted in the statistical framework that, given the assumptions on the success of the qualitative V&V and QA procedures, significantly reduces the amount of testing needed to confidently assess reliability at so-called high and ultra-high levels (10-4 or higher). The coming years shall address the methodologies to realistically estimate the impacts of various V&V techniques to system reliability and include the impact of operational risk to reliability assessment. Combine formal correctness verification, process and product metrics, and other standard qualitative software assurance methods with statistical testing with the aim of gaining higher confidence in software reliability assessment for high-assurance applications. B) Quantify the impact of these methods on software reliability. C) Demonstrate that accounting for the effectiveness of these methods reduces the number of tests needed to attain certain confidence level. D) Quantify and justify the reliability estimate for systems developed using various methods.
A comprehensive review of the psychometric properties of the Drug Abuse Screening Test.
Yudko, Errol; Lozhkina, Olga; Fouts, Adriana
2007-03-01
This article reviews the reliability and the validity of the (10-, 20-, and 28-item) Drug Abuse Screening Test (DAST). The reliability and the validity of the adolescent version of the DAST are also reviewed. An extensive literature review was conducted using the Medline and Psychinfo databases from the years 1982 to 2005. All articles that addressed the reliability and the validity of the DAST were examined. Publications in which the DAST was used as a screening tool but had no data on its psychometric properties were not included. Descriptive information about each version of the test, as well as discussion of the empirical literature that has explored measures of the reliability and the validity of the DAST, has been included. The DAST tended to have moderate to high levels of test-retest, interitem, and item-total reliabilities. The DAST also tended to have moderate to high levels of validity, sensitivity, and specificity. In general, all versions of the DAST yield satisfactory measures of reliability and validity for use as clinical or research tools. Furthermore, these tests are easy to administer and have been used in a variety of populations.
Objective measurements of excess skin in post bariatric patients--inter-rater reliability.
Biörserud, Christina; Fagevik Olsén, Monika; Elander, Anna; Wiklund, Malin
2016-01-01
An ability to reliably assess excess skin after massive weight loss using well-described and transferrable methods is important. The aim of this trial was to evaluate inter-rater reliability of ptosis and circumference measurements in patients with excess skin after bariatric surgery. Twenty-five postbariatric patients were included in the study, and their excess skin was measured 18 months after surgery. A protocol was designed to measure excess skin in a standardised way. To evaluate the inter-rater reliability in the measuring protocol, all patients were measured twice, by a specialist nurse and a specialist physiotherapist. All circumference measurements on different body parts had an ICC > 0.9, indicating high reliability. Furthermore, all breast and abdominal ptosis measurements had high reliability. In contrast, visual evaluation of abdominal ptosis had poor reliability. Measurements of ptoses on different body parts had an ICC > 0.6. There were no systematic differences between the results of the two testers, except for measurements of the buttocks and maximal knee circumference. The measuring protocol presented in this study has high reliability and, therefore, represents a useful instrument to provide a consistent and objective assessment of excess skin in the postbariatric patient.
Anne E. Black; Brooke Baldauf McBride
2013-01-01
In an effort to improve organizational outcomes, including safety, in wildland fire management, researchers and practitioners have turned to a domain of research on organizational performance known as High Reliability Organizing (HRO). The HRO paradigm emerged in the late 1980s in an effort to identify commonalities among organizations that function under hazardous...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Logan, Jeffrey S.; Paranhos, Elizabeth; Kozak, Tracy G.
This study focuses on onshore natural gas operations and examines the extent to which oil and gas firms have embraced certain organizational characteristics that lead to 'high reliability' - understood here as strong safety and reliability records over extended periods of operation. The key questions that motivated this study include whether onshore oil and gas firms engaged in exploration and production (E&P) and midstream (i.e., natural gas transmission and storage) are implementing practices characteristic of high reliability organizations (HROs) and the extent to which any such practices are being driven by industry innovations and standards and/or regulatory requirements.
Memorial Hermann: high reliability from board to bedside.
Shabot, M Michael; Monroe, Douglas; Inurria, Juan; Garbade, Debbi; France, Anne-Claire
2013-06-01
In 2006 the Memorial Hermann Health System (MHHS), which includes 12 hospitals, began applying principles embraced by high reliability organizations (HROs). Three factors support its HRO journey: (1) aligned organizational structure with transparent management systems and compressed reporting processes; (2) Robust Process Improvement (RPI) with high-reliability interventions; and (3) cultural establishment, sustainment, and evolution. The Quality and Safety strategic plan contains three domains, each with a specific set of measures that provide goals for performance: (1) "Clinical Excellence;" (2) "Do No Harm;" and (3) "Saving Lives," as measured by the Serious Safety Event rate. MHHS uses a uniform approach to performance improvement--RPI, which includes Six Sigma, Lean, and change management, to solve difficult safety and quality problems. The 9 acute care hospitals provide multiple opportunities to integrate high-reliability interventions and best practices across MHHS. For example, MHHS partnered with the Joint Commission Center for Transforming Healthcare in its inaugural project to establish reliable hand hygiene behaviors, which improved MHHS's average hand hygiene compliance rate from 44% to 92% currently. Soon after compliance exceeded 85% at all 12 hospitals, the average rate of central line-associated bloodstream and ventilator-associated pneumonias decreased to essentially zero. MHHS's size and diversity require a disciplined approach to performance improvement and systemwide achievement of measurable success. The most significant cultural change at MHHS has been the expectation for 100% compliance with evidence-based quality measures and 0% incidence of patient harm.
Reliability in endoscopic diagnosis of portal hypertensive gastropathy
de Macedo, George Fred Soares; Ferreira, Fabio Gonçalves; Ribeiro, Maurício Alves; Szutan, Luiz Arnaldo; Assef, Mauricio Saab; Rossini, Lucio Giovanni Battista
2013-01-01
AIM: To analyze reliability among endoscopists in diagnosing portal hypertensive gastropathy (PHG) and to determine which criteria from the most utilized classifications are the most suitable. METHODS: From January to July 2009, in an academic quaternary referral center at Santa Casa of São Paulo Endoscopy Service, Brazil, we performed this single-center prospective study. In this period, we included 100 patients, including 50 sequential patients who had portal hypertension of various etiologies; who were previously diagnosed based on clinical, laboratory and imaging exams; and who presented with esophageal varices. In addition, our study included 50 sequential patients who had dyspeptic symptoms and were referred for upper digestive endoscopy without portal hypertension. All subjects underwent upper digestive endoscopy, and the images of the exam were digitally recorded. Five endoscopists with more than 15 years of experience answered an electronic questionnaire, which included endoscopic criteria from the 3 most commonly used Portal Hypertensive Gastropathy classifications (McCormack, NIEC and Baveno) and the presence of elevated or flat antral erosive gastritis. All five endoscopists were blinded to the patients’ clinical information, and all images of varices were deliberately excluded for the analysis. RESULTS: The three most common etiologies of portal hypertension were schistosomiasis (36%), alcoholic cirrhosis (20%) and viral cirrhosis (14%). Of the 50 patients with portal hypertension, 84% were Child A, 12% were Child B, 4% were Child C, 64% exhibited previous variceal bleeding and 66% were previously endoscopic treated. The endoscopic parameters, presence or absence of mosaic-like pattern, red point lesions and cherry-red spots were associated with high inter-observer reliability and high specificity for diagnosing Portal Hypertensive Gastropathy. Sensitivity, specificity and reliability for the diagnosis of PHG (%) were as follows: mosaic-like pattern (100; 92.21; High); fine pink speckling (56; 76.62; Unsatisfactory); superficial reddening (69.57; 66.23; Unsatisfactory); red-point lesions (47.83; 90.91; High); cherry-red spots (39.13; 96.10; High); isolated red marks (43.48; 88.31; High); and confluent red marks (21.74; 100; Unsatisfactory). Antral elevated erosive gastritis exhibited high reliability and high specificity with respect to the presence of portal hypertension (92%) and the diagnosis of portal hypertensive gastropathy (88.31%). CONCLUSION: The most suitable endoscopic criteria for the diagnosis of PHG were mosaic-like pattern, red-point lesions and cherry-red spots with no subdivisions, which were associated with a high rate of inter-observer reliability. PMID:23858376
The 5K70SK automatically tuned, high power, S-band klystron
NASA Technical Reports Server (NTRS)
Goldfinger, A.
1977-01-01
Primary objectives include delivery of 44 5K70SK klystron amplifier tubes and 26 remote tuner assemblies with spare parts kits. Results of a reliability demonstration on a klystron test cavity are discussed, along with reliability tests performed on a remote tuning unit. Production problems and one design modification are reported and discussed. Results of PAT and DVT are included.
RELIABILITY, AVAILABILITY, AND SERVICEABILITY FOR PETASCALE HIGH-END COMPUTING AND BEYOND
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chokchai "Box" Leangsuksun
2011-05-31
Our project is a multi-institutional research effort that adopts interplay of RELIABILITY, AVAILABILITY, and SERVICEABILITY (RAS) aspects for solving resilience issues in highend scientific computing in the next generation of supercomputers. results lie in the following tracks: Failure prediction in a large scale HPC; Investigate reliability issues and mitigation techniques including in GPGPU-based HPC system; HPC resilience runtime & tools.
Barrett, Eva; McCreesh, Karen; Lewis, Jeremy
2014-02-01
A wide array of instruments are available for non-invasive thoracic kyphosis measurement. Guidelines for selecting outcome measures for use in clinical and research practice recommend that properties such as validity and reliability are considered. This systematic review reports on the reliability and validity of non-invasive methods for measuring thoracic kyphosis. A systematic search of 11 electronic databases located studies assessing reliability and/or validity of non-invasive thoracic kyphosis measurement techniques. Two independent reviewers used a critical appraisal tool to assess the quality of retrieved studies. Data was extracted by the primary reviewer. The results were synthesized qualitatively using a level of evidence approach. 27 studies satisfied the eligibility criteria and were included in the review. The reliability, validity and both reliability and validity were investigated by sixteen, two and nine studies respectively. 17/27 studies were deemed to be of high quality. In total, 15 methods of thoracic kyphosis were evaluated in retrieved studies. All investigated methods showed high (ICC ≥ .7) to very high (ICC ≥ .9) levels of reliability. The validity of the methods ranged from low to very high. The strongest levels of evidence for reliability exists in support of the Debrunner kyphometer, Spinal Mouse and Flexicurve index, and for validity supports the arcometer and Flexicurve index. Further reliability and validity studies are required to strengthen the level of evidence for the remaining methods of measurement. This should be addressed by future research. Copyright © 2013 Elsevier Ltd. All rights reserved.
Janse, Ingmar; Hamidjaja, Raditijo A; Bok, Jasper M; van Rotterdam, Bart J
2010-12-08
Several pathogens could seriously affect public health if not recognized timely. To reduce the impact of such highly pathogenic micro-organisms, rapid and accurate diagnostic tools are needed for their detection in various samples, including environmental samples. Multiplex real-time PCRs were designed for rapid and reliable detection of three major pathogens that have the potential to cause high morbidity and mortality in humans: B. anthracis, F. tularensis and Y. pestis. The developed assays detect three pathogen-specific targets, including at least one chromosomal target, and one target from B. thuringiensis which is used as an internal control for nucleic acid extraction from refractory spores as well as successful DNA amplification. Validation of the PCRs showed a high analytical sensitivity, specificity and coverage of diverse pathogen strains. The multiplex qPCR assays that were developed allow the rapid detection of 3 pathogen-specific targets simultaneously, without compromising sensitivity. The application of B. thuringiensis spores as internal controls further reduces false negative results. This ensures highly reliable detection, while template consumption and laboratory effort are kept at a minimum.
2010-01-01
Background Several pathogens could seriously affect public health if not recognized timely. To reduce the impact of such highly pathogenic micro-organisms, rapid and accurate diagnostic tools are needed for their detection in various samples, including environmental samples. Results Multiplex real-time PCRs were designed for rapid and reliable detection of three major pathogens that have the potential to cause high morbidity and mortality in humans: B. anthracis, F. tularensis and Y. pestis. The developed assays detect three pathogen-specific targets, including at least one chromosomal target, and one target from B. thuringiensis which is used as an internal control for nucleic acid extraction from refractory spores as well as successful DNA amplification. Validation of the PCRs showed a high analytical sensitivity, specificity and coverage of diverse pathogen strains. Conclusions The multiplex qPCR assays that were developed allow the rapid detection of 3 pathogen-specific targets simultaneously, without compromising sensitivity. The application of B. thuringiensis spores as internal controls further reduces false negative results. This ensures highly reliable detection, while template consumption and laboratory effort are kept at a minimum PMID:21143837
NASA Technical Reports Server (NTRS)
Gillespie, Amanda M.
2012-01-01
The future of Space Exploration includes missions to the moon, asteroids, Mars, and beyond. To get there, the mission concept is to launch multiple launch vehicles months, even years apart. In order to achieve this, launch vehicles, payloads (satellites and crew capsules), and ground systems must be highly reliable and/or available, to include maintenance concepts and procedures in the event of a launch scrub. In order to achieve this high probability of mission success, Ground Systems Development and Operations (GSDO) has allocated Reliability, Maintainability, and Availability (RMA) requirements to all hardware and software required for both launch operations and, in the event of a launch scrub, required to support a repair of the ground systems, launch vehicle, or payload. This is done concurrently with the design process (30/60/90 reviews).
physical phenomena, PV package reliability, and outdoor PV performance. At NREL, he performs research in advanced concept PV modules. Dr. Silverman studies the performance and reliability of PV modules, including previously studied the degradation of solder joints in high-concentration PV and the outdoor performance of
Downs, Stephen; Marquez, Jodie; Chiarelli, Pauline
2013-06-01
What is the intra-rater and inter-rater relative reliability of the Berg Balance Scale? What is the absolute reliability of the Berg Balance Scale? Does the absolute reliability of the Berg Balance Scale vary across the scale? Systematic review with meta-analysis of reliability studies. Any clinical population that has undergone assessment with the Berg Balance Scale. Relative intra-rater reliability, relative inter-rater reliability, and absolute reliability. Eleven studies involving 668 participants were included in the review. The relative intrarater reliability of the Berg Balance Scale was high, with a pooled estimate of 0.98 (95% CI 0.97 to 0.99). Relative inter-rater reliability was also high, with a pooled estimate of 0.97 (95% CI 0.96 to 0.98). A ceiling effect of the Berg Balance Scale was evident for some participants. In the analysis of absolute reliability, all of the relevant studies had an average score of 20 or above on the 0 to 56 point Berg Balance Scale. The absolute reliability across this part of the scale, as measured by the minimal detectable change with 95% confidence, varied between 2.8 points and 6.6 points. The Berg Balance Scale has a higher absolute reliability when close to 56 points due to the ceiling effect. We identified no data that estimated the absolute reliability of the Berg Balance Scale among participants with a mean score below 20 out of 56. The Berg Balance Scale has acceptable reliability, although it might not detect modest, clinically important changes in balance in individual subjects. The review was only able to comment on the absolute reliability of the Berg Balance Scale among people with moderately poor to normal balance. Copyright © 2013 Australian Physiotherapy Association. Published by .. All rights reserved.
Lersilp, Suchitporn; Suchart, Sumana
2017-01-01
The purpose of this study was to improve upon the first version of the basic work skills assessment tool for adolescents with autism spectrum disorder (ASD) and examine interrater and intrarater reliability using Intraclass Correlation Coefficient (ICC). The modified tool includes 2 components: (1) three tasks measuring work abilities and work attitudes and (2) a form to record the number of verbal and nonverbal prompts. 26 participants were selected by purposive sampling and divided into 3 groups—group 1 (10 subjects, aged 11–13 years), group 2 (10, aged 14–16 years), and group 3 (6, aged 17–19 years). The results show that interrater reliabilities of work abilities and work attitudes were high in all groups except that the work attitude in group 1 was moderate. Intrarater reliabilities of work abilities in group 1 and group 2 were high. Group 3 was moderate. Intrarater reliabilities of work attitudes in group 1 and group 3 were high but not in group 2 in which they were moderate. Nevertheless, interrater and intrarater reliabilities in the total scores of all groups were high, which implies that this tool is applicable for adolescents aged 11–19 years with consideration of relevance for each group. PMID:28280769
Morrison, Melanie A.; Churchill, Nathan W.; Cusimano, Michael D.; Schweizer, Tom A.; Das, Sunit; Graham, Simon J.
2016-01-01
Background Functional magnetic resonance imaging (fMRI) continues to develop as a clinical tool for patients with brain cancer, offering data that may directly influence surgical decisions. Unfortunately, routine integration of preoperative fMRI has been limited by concerns about reliability. Many pertinent studies have been undertaken involving healthy controls, but work involving brain tumor patients has been limited. To develop fMRI fully as a clinical tool, it will be critical to examine these reliability issues among patients with brain tumors. The present work is the first to extensively characterize differences in activation map quality between brain tumor patients and healthy controls, including the effects of tumor grade and the chosen behavioral testing paradigm on reliability outcomes. Method Test-retest data were collected for a group of low-grade (n = 6) and high-grade glioma (n = 6) patients, and for matched healthy controls (n = 12), who performed motor and language tasks during a single fMRI session. Reliability was characterized by the spatial overlap and displacement of brain activity clusters, BOLD signal stability, and the laterality index. Significance testing was performed to assess differences in reliability between the patients and controls, and low-grade and high-grade patients; as well as between different fMRI testing paradigms. Results There were few significant differences in fMRI reliability measures between patients and controls. Reliability was significantly lower when comparing high-grade tumor patients to controls, or to low-grade tumor patients. The motor task produced more reliable activation patterns than the language tasks, as did the rhyming task in comparison to the phonemic fluency task. Conclusion In low-grade glioma patients, fMRI data are as reliable as healthy control subjects. For high-grade glioma patients, further investigation is required to determine the underlying causes of reduced reliability. To maximize reliability outcomes, testing paradigms should be carefully selected to generate robust activation patterns. PMID:26894279
Examination of Anomalous World Experience: A Report on Reliability.
Conerty, Joseph; Skodlar, Borut; Pienkos, Elizabeth; Zadravek, Tina; Byrom, Greg; Sass, Louis
2017-01-01
The EAWE (Examination of Anomalous World Experience) is a newly developed, semi-structured interview that aims to capture anomalies of subjectivity, common in schizophrenia spectrum disorders, that pertain to experiences of the lived world, including space, time, people, language, atmosphere, and certain existential attitudes. By contrast, previous empirical studies of subjective experience in schizophrenia have focused largely on disturbances in self-experience. To assess the reliability of the EAWE, including internal consistency and interrater reliability. In the course of developing the EAWE, two distinct studies were conducted, one in the United States and the other in Slovenia. Thirteen patients diagnosed with schizophrenia spectrum or mood disorders were recruited for the US study. Fifteen such patients were recruited for the Slovenian study. Two live interviewers conducted the EAWE in the US. The Slovenian interviews were completed by one live interviewer with a second rater reviewing audiorecordings of the interview. Internal consistency and interrater reliability were calculated independently for each study, utilizing Cronbach's α, Spearman's ρ, and Cohen's κ. Each study yielded high internal consistency (Cronbach's α >0.82) and high interrater reliability for total EAWE scores (ρ > 0.83; average κ values were at least 0.78 for each study, with EAWE domain-specific κ not lower than 0.73). The EAWE, containing world-oriented inquiries into anomalies in subjective experience, has adequate reliability for use in a clinical or research setting. © 2017 S. Karger AG, Basel.
Creating High Reliability in Health Care Organizations
Pronovost, Peter J; Berenholtz, Sean M; Goeschel, Christine A; Needham, Dale M; Sexton, J Bryan; Thompson, David A; Lubomski, Lisa H; Marsteller, Jill A; Makary, Martin A; Hunt, Elizabeth
2006-01-01
Objective The objective of this paper was to present a comprehensive approach to help health care organizations reliably deliver effective interventions. Context Reliability in healthcare translates into using valid rate-based measures. Yet high reliability organizations have proven that the context in which care is delivered, called organizational culture, also has important influences on patient safety. Model for Improvement Our model to improve reliability, which also includes interventions to improve culture, focuses on valid rate-based measures. This model includes (1) identifying evidence-based interventions that improve the outcome, (2) selecting interventions with the most impact on outcomes and converting to behaviors, (3) developing measures to evaluate reliability, (4) measuring baseline performance, and (5) ensuring patients receive the evidence-based interventions. The comprehensive unit-based safety program (CUSP) is used to improve culture and guide organizations in learning from mistakes that are important, but cannot be measured as rates. Conclusions We present how this model was used in over 100 intensive care units in Michigan to improve culture and eliminate catheter-related blood stream infections—both were accomplished. Our model differs from existing models in that it incorporates efforts to improve a vital component for system redesign—culture, it targets 3 important groups—senior leaders, team leaders, and front line staff, and facilitates change management—engage, educate, execute, and evaluate for planned interventions. PMID:16898981
Reliability and Validity of Advanced Phonics Measures
ERIC Educational Resources Information Center
Doty, Sara J.; Hixson, Michael D.; Decker, Dawn M.; Reynolds, Jennifer L.; Drevon, Daniel D.
2015-01-01
Two studies explored the technical adequacy of various measures of advanced phonics skills. In Study 1, the advanced phonics measures consisted of pseudowords, real words, or a combination of both. Participants included 39 students in the third grade. Test-retest correlations for all measures were above 0.8 and interrater reliability was high.…
Engineering Design Handbook. Development Guide for Reliability. Part Two. Design for Reliability
1976-01-01
Component failure rates, however, have been recorded by many sources as a function of use and environment. Some of these sources are listed in Refs. 13-17...other systems capable of creating an explosive reac- tion. The second category is fairly obvious and includes many variations on methods for providing...aboutthem. 4. Ability to detect signals ( including patterns) in high noise environments. 5. Ability to store large amounts of informa- tion for long
Physical activity questionnaires for youth: a systematic review of measurement properties.
Chinapaw, Mai J M; Mokkink, Lidwine B; van Poppel, Mireille N M; van Mechelen, Willem; Terwee, Caroline B
2010-07-01
Because of the diversity in available questionnaires, it is not easy for researchers to decide which instrument is most suitable for his or her specific demands. Therefore, we systematically summarized and appraised studies examining measurement properties of self-administered and proxy-reported physical activity (PA) questionnaires in youth. Literature was identified through searching electronic databases (PubMed, EMBASE using 'EMBASE only' and SportDiscus) until May 2009. Studies were included if they reported on the measurement properties of self-administered and proxy-reported PA questionnaires in youth (mean age <18 years) and were published in the English language. Methodological quality and results of included studies was appraised using a standardized checklist (qualitative attributes and measurement properties of PA questionnaires [QAPAQ]). We included 54 manuscripts examining 61 versions of questionnaires. None of the included questionnaires showed both acceptable reliability and validity. Only seven questionnaires received a positive rating for reliability. Reported validity varied, with correlations between PA questionnaires and accelerometers ranging from very low to high (previous day PA recall: correlation coefficient [r] = 0.77). In general, PA questionnaires for adolescents correlated better with accelerometer scores than did those for children. From this systematic review, we conclude that no questionnaires were available with both acceptable reliability and validity. Considerably more high-quality research is required to examine the validity and reliability of promising PA questionnaires for youth.
Compact high reliability fiber coupled laser diodes for avionics and related applications
NASA Astrophysics Data System (ADS)
Daniel, David R.; Richards, Gordon S.; Janssen, Adrian P.; Turley, Stephen E. H.; Stockton, Thomas E.
1993-04-01
This paper describes a newly developed compact high reliability fiber coupled laser diode which is capable of providing enhanced performance under extreme environmental conditions including a very wide operating temperature range. Careful choice of package materials to minimize thermal and mechanical stress, used with proven manufacturing methods, has resulted in highly stable coupling of the optical fiber pigtail to a high performance MOCVD-grown Multi-Quantum Well laser chip. Electro-optical characteristics over temperature are described together with a demonstration of device stability over a range of environmental conditions. Real time device lifetime data is also presented.
Adogwa, Owoicho; Elsamadicy, Aladine A; Cheng, Joseph; Bagley, Carlos
2016-03-01
The prospective acquisition of reliable patient-reported outcomes (PROs) measures demonstrating the effectiveness of spine surgery, or lack thereof, remains a challenge. The aims of this study are to compare the reliability of functional outcomes metrics obtained using full time employee (FTE) vs. non-FTE-dependent methodologies and to determine the independent predictors of response reliability using non FTE-dependent methodologies. One hundred and nineteen adult patients (male: 65, female: 54) undergoing one- and two-level lumbar fusions at Duke University Medical Center were enrolled in this prospective study. Enrollment criteria included available demographic, clinical and baseline functional outcomes data. All patients were administered two similar sets of baseline questionnaires-(I) phone interviews (FTE-dependent) and (II) hardcopy in clinic (patient self-survey, non-FTE-dependent). All patients had at least a two-week washout period between phone interviews and in-clinic self-surveys to minimize effect of recall. Questionnaires included Oswestry disability index (ODI) and Visual Analog Back and Leg Pain Scale (VAS-BP/LP). Reliability was assessed by the degree to which patient responses to baseline questionnaires differed between both time points. About 26.89% had a history an anxiety disorder and 28.57% reported a history of depression. At least 97.47% of patients had a High School Diploma or GED, with 49.57% attaining a 4-year college degree or post-graduate degree. 29.94% reported full-time employment and 14.28% were on disability. There was a very high correlation between baseline PRO's data captured between FTE-dependent compared to non-FTE-dependent methodologies (r=0.89). In a multivariate logistic regression model, the absence of anxiety and depression, higher levels of education (college or greater) and full-time employment, were independently associated with high response reliability using non-FTE-dependent methodologies. Our study suggests that capturing health-related quality of life data using non-FTE-dependent methodologies is highly reliable and maybe a more cost-effective alternative. Well-educated patients who are employed full-time appear to be the most reliable.
Mechanical System Reliability and Cost Integration Using a Sequential Linear Approximation Method
NASA Technical Reports Server (NTRS)
Kowal, Michael T.
1997-01-01
The development of new products is dependent on product designs that incorporate high levels of reliability along with a design that meets predetermined levels of system cost. Additional constraints on the product include explicit and implicit performance requirements. Existing reliability and cost prediction methods result in no direct linkage between variables affecting these two dominant product attributes. A methodology to integrate reliability and cost estimates using a sequential linear approximation method is proposed. The sequential linear approximation method utilizes probability of failure sensitivities determined from probabilistic reliability methods as well a manufacturing cost sensitivities. The application of the sequential linear approximation method to a mechanical system is demonstrated.
Learning high-quality soldering
NASA Technical Reports Server (NTRS)
Read, W. S.
1981-01-01
Soldering techniques for high-reliability electronic equipment are taught in 5 day course at NASA's Jet Propulsion Laboratory. Topic covered include new circuit assembly, printed-wiring board reworking, circuit changes, wire routing, and component installation.
High power diode lasers for solid-state laser pumps
NASA Technical Reports Server (NTRS)
Linden, Kurt J.; Mcdonnell, Patrick N.
1994-01-01
The development and commercial application of high power diode laser arrays for use as solid-state laser pumps is described. Such solid-state laser pumps are significantly more efficient and reliable than conventional flash-lamps. This paper describes the design and fabrication of diode lasers emitting in the 780 - 900 nm spectral region, and discusses their performance and reliability. Typical measured performance parameters include electrical-to-optical power conversion efficiencies of 50 percent, narrow-band spectral emission of 2 to 3 nm FWHM, pulsed output power levels of 50 watts/bar with reliability values of over 2 billion shots to date (tests to be terminated after 10 billion shots), and reliable operation to pulse lengths of 1 ms. Pulse lengths up to 5 ms have been demonstrated at derated power levels, and CW performance at various power levels has been evaluated in a 'bar-in-groove' laser package. These high-power 1-cm stacked-bar arrays are now being manufactured for OEM use. Individual diode laser bars, ready for package-mounting by OEM customers, are being sold as commodity items. Commercial and medical applications of these laser arrays include solid-state laser pumping for metal-working, cutting, industrial measurement and control, ranging, wind-shear/atmospheric turbulence detection, X-ray generation, materials surface cleaning, microsurgery, ophthalmology, dermatology, and dental procedures.
Elvrum, Ann-Kristin G; Beckung, Eva; Sæther, Rannei; Lydersen, Stian; Vik, Torstein; Himmelmann, Kate
2017-08-01
To develop a revised edition of the Bimanual Fine Motor Function (BFMF 2), as a classification of fine motor capacity in children with cerebral palsy (CP), and establish intra- and interrater reliability of this edition. The content of the original BFMF was discussed by an expert panel, resulting in a revised edition comprising the original description of the classification levels, but in addition including figures with specific explanatory text. Four professionals classified fine motor function of 79 children (3-17 years; 45 boys) who represented all subtypes of CP and Manual Ability Classification levels (I-V). Intra- and inter-rater reliability was assessed using overall intra-class correlation coefficient (ICC), and Cohen's quadratic weighted kappa. The overall ICC was 0.86. Cohen's weighted kappa indicated high intra-rater (к w : >0.90) and inter-rater (к w : >0.85) reliability. The revised BFMF 2 had high intra- and interrater reliability. The classification levels could be determined from short video recordings (<5 minutes), using the figures and precise descriptions of the fine motor function levels included in the BFMF 2. Thus, the BFMF 2 may be a feasible and useful classification of fine motor capacity both in research and in clinical practice.
Reliability study of high-brightness multiple single emitter diode lasers
NASA Astrophysics Data System (ADS)
Zhu, Jing; Yang, Thomas; Zhang, Cuipeng; Lang, Chao; Jiang, Xiaochen; Liu, Rui; Gao, Yanyan; Guo, Weirong; Jiang, Yuhua; Liu, Yang; Zhang, Luyan; Chen, Louisa
2015-03-01
In this study the chip bonding processes for various chips from various chip suppliers around the world have been optimized to achieve reliable chip on sub-mount for high performance. These chip on sub-mounts, for examples, includes three types of bonding, 8xx nm-1.2W/10.0W Indium bonded lasers, 9xx nm 10W-20W AuSn bonded lasers and 1470 nm 6W Indium bonded lasers will be reported below. The MTTF@25 of 9xx nm chip on sub-mount (COS) is calculated to be more than 203,896 hours. These chips from various chip suppliers are packaged into many multiple single emitter laser modules, using similar packaging techniques from 2 emitters per module to up to 7 emitters per module. A reliability study including aging test is performed on those multiple single emitter laser modules. With research team's 12 years' experienced packaging design and techniques, precise optical and fiber alignment processes and superior chip bonding capability, we have achieved a total MTTF exceeding 177,710 hours of life time with 60% confidence level for those multiple single emitter laser modules. Furthermore, a separated reliability study on wavelength stabilized laser modules have shown this wavelength stabilized module packaging process is reliable as well.
NASA Astrophysics Data System (ADS)
Sin, Yongkun; Bonsall, Jeremy; Lingley, Zachary; Brodie, Miles; Mason, Maribeth
2017-02-01
High electron mobility transistors (HEMTs) based on AlGaN-GaN hetero-structures are finding an increasing number of commercial and military applications that require high voltage, high power, and high efficiency operation. In recent years, leading GaN HEMT manufacturers have reported excellent RF power characteristics and encouraging reliability, but long-term reliability in the space environment still remains a major concern due to a large number of defects and traps present both in the bulk as well as at the surface, leading to undesirable characteristics including current collapse. Furthermore, degradation mechanisms in GaN HEMTs are still not well understood. Thus, reliability and radiation effects of GaN HEMTs should be studied before solid state power amplifiers (SSPAs) based on GaN HEMT technology are successfully deployed in space satellite systems. For the present study, we investigated electrical characteristics of high-power GaN HEMTs irradiated with protons and heavy ions under various irradiation and biasing conditions.
Reliability-Related Issues in the Context of Student Evaluations of Teaching in Higher Education
ERIC Educational Resources Information Center
Kalender, Ilker
2015-01-01
Student evaluations of teaching (SET) have been the principal instrument to elicit students' opinions in higher education institutions. Many decisions, including high-stake ones, are made based on SET scores reported by students. In this respect, reliability of SET scores is of considerable importance. This paper has an argument that there are…
Test Re-Test Reliability of Four Versions of the 3-Cone Test in Non-Athletic Men
Langley, Jason G.; Chetlin, Robert D.
2017-01-01
Until recently, measurement and evaluation in sport science, especially agility testing, has not always included key elements of proper test construction. Often tests are published without reporting reliability and validity analysis for a specific population. The purpose of the present study was to examine the test re-test reliability of four versions of the 3-Cone Test (3CT), and provide guidance on proper test construction for testing agility in athletic populations. Forty male students enrolled in classes in the Department of Physical Education at a mid-Atlantic university participated. On each of test day participants performed 10 trials. In random order, they performed three trials to the right (3CTR, standard test), three to the left (3CTL), and two modified trials (3CTAR and 3CTAL), which included a reactive component in which a visual cue was given to indicate direction. Intra-class correlation coefficients (ICC) indicated a moderate to high reliability for the four tests, 3CTR 0.79 (0.64-0.88, 95%CI), 3CTL 0.73 (0.55-0.85), 3CTAR 0.85(0.74-0.92), and 3CTAL 0.79 (0.64-0.88). Small standard error of the measurement (SEM) was found; range 0.09 to 0.10. Pearson correlations between tests were high (0.82-0.92) on day one as well as day two (0.72-0.85). These results indicate each version of the 3-Cone Test is reliable; however, further tests are needed with specific athletic populations. Only the 3CTAR and 3CTAL are tests of agility due to the inclusion of a reactive component. Future studies examining agility testing and training should incorporate technological elements, including automated timing systems and motion capture analysis. Such instrumentation will allow for optimal design of tests that simulate sport-specific game conditions. Key points The commonly used 3-cone test (upside down “L” to the right”) is a reliable change of direction speed (CODS) test when evaluating collegiate males. A modification of the CODS 3-cone test (upside down “L” to the left instead of to the right) is also reliable for evaluating collegiate males. A modification of the 3-cone that includes reaction and a choice of a cut to the left or right remains reliable as now an agility test version in collegiate males. There are moderate to high correlation between the 4 versions of the tests. Reaction remains a critical to the design of testing and training agility protocols, and should be investigated similarly to various athletes including novice/expert, male/female, and nearly every sporting event. PMID:28344450
NASA Technical Reports Server (NTRS)
Duffy, Stephen F.; Gyekenyesi, John P.
1989-01-01
Presently there are many opportunities for the application of ceramic materials at elevated temperatures. In the near future ceramic materials are expected to supplant high temperature metal alloys in a number of applications. It thus becomes essential to develop a capability to predict the time-dependent response of these materials. The creep rupture phenomenon is discussed, and a time-dependent reliability model is outlined that integrates continuum damage mechanics principles and Weibull analysis. Several features of the model are presented in a qualitative fashion, including predictions of both reliability and hazard rate. In addition, a comparison of the continuum and the microstructural kinetic equations highlights a strong resemblance in the two approaches.
Sekir, U; Yildiz, Y; Hazneci, B; Ors, F; Saka, T; Aydin, T
2008-12-01
In contrast to the single evaluation methods used in the past, the combination of multiple tests allows one to obtain a global assessment of the ankle joint. The aim of this study was to determine the reliability of the different tests in a functional test battery. Twenty-four male recreational athletes with unilateral functional ankle instability (FAI) were recruited for this study. One component of the test battery included five different functional ability tests. These tests included a single limb hopping course, single-legged and triple-legged hop for distance, and six and cross six meter hop for time. The ankle joint position sense and one leg standing test were used for evaluation of proprioception and sensorimotor control. The isokinetic strengths of the ankle invertor and evertor muscles were evaluated at a velocity of 120 degrees /s. The reliability of the test battery was assessed by calculating the intraclass correlation coefficient (ICC). Each subject was tested two times, with an interval of 3-5 days between the test sessions. The ICCs for ankle functional and proprioceptive ability showed high reliability (ICCs ranging from 0.94 to 0.98). Additionally, isokinetic ankle joint inversion and eversion strength measurements represented good to high reliability (ICCs between 0.82 and 0.98). The functional test battery investigated in this study proved to be a reliable tool for the assessment of athletes with functional ankle instability. Therefore, clinicians may obtain reliable information from the functional test battery during the assessment of ankle joint performance in patients with functional ankle instability.
State recovery and lockstep execution restart in a system with multiprocessor pairing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gara, Alan; Gschwind, Michael K; Salapura, Valentina
System, method and computer program product for a multiprocessing system to offer selective pairing of processor cores for increased processing reliability. A selective pairing facility is provided that selectively connects, i.e., pairs, multiple microprocessor or processor cores to provide one highly reliable thread (or thread group). Each paired microprocessor or processor cores that provide one highly reliable thread for high-reliability connect with a system components such as a memory "nest" (or memory hierarchy), an optional system controller, and optional interrupt controller, optional I/O or peripheral devices, etc. The memory nest is attached to a selective pairing facility via a switchmore » or a bus. Each selectively paired processor core is includes a transactional execution facility, whereing the system is configured to enable processor rollback to a previous state and reinitialize lockstep execution in order to recover from an incorrect execution when an incorrect execution has been detected by the selective pairing facility.« less
Reliability analysis of instrument design of noninvasive bone marrow disease detector
NASA Astrophysics Data System (ADS)
Su, Yu; Li, Ting; Sun, Yunlong
2016-02-01
Bone marrow is an important hematopoietic organ, and bone marrow lesions (BMLs) may cause a variety of complications with high death rate and short survival time. Early detection and follow up care are particularly important. But the current diagnosis methods rely on bone marrow biopsy/puncture, with significant limitations such as invasion, complex operation, high risk, and discontinuous. It is highly in need of a non-invasive, safe, easily operated, and continuous monitoring technology. So we proposed to design a device aimed for detecting bone marrow lesions, which was based on near infrared spectrum technology. Then we fully tested its reliabilities, including the sensitivity, specificity, signal-to-noise ratio (SNR), stability, and etc. Here, we reported this sequence of reliability test experiments, the experimental results, and the following data analysis. This instrument was shown to be very sensitive, with distinguishable concentration less than 0.002 and with good linearity, stability and high SNR. Finally, these reliability-test data supported the promising clinical diagnosis and surgery guidance of our novel instrument in detection of BMLs.
A case of the birth and death of a high reliability healthcare organisation.
Roberts, K H; Madsen, P; Desai, V; Van Stralen, D
2005-06-01
High reliability organisations (HROs) are those in which errors rarely occur. To accomplish this they conduct relatively error free operations over long periods of time and make consistently good decisions resulting in high quality and reliability. Some organisational processes that characterise HROs are process auditing, implementing appropriate reward systems, avoiding quality degradation, appropriately perceiving that risk exists and developing strategies to deal with it, and command and control. Command and control processes include migrating decision making, redundancy in people or hardware, developing situational awareness, formal rules and procedures, and training. These processes must be tailored to the specific organisation implementing them. These processes were applied to a paediatric intensive care unit (PICU) where care was derived from problem solving methodology rather than protocol. After a leadership change, the unit returned to the hierarchical medical model of care. Important outcome variables such as infant mortality, patient return to the PICU after discharge, days on the PICU, air transports, degraded. Implications for clinical practice include providing caregivers with sufficient flexibility to meet changing situations, encouraging teamwork, and avoiding shaming, naming, and blaming.
Lee, In-Kyu; Lee, Kwan Hyi; Lee, Seok; Cho, Won-Ju
2014-12-24
We used a microwave annealing process to fabricate a highly reliable biosensor using amorphous-InGaZnO (a-IGZO) thin-film transistors (TFTs), which usually experience threshold voltage instability. Compared with furnace-annealed a-IGZO TFTs, the microwave-annealed devices showed superior threshold voltage stability and performance, including a high field-effect mobility of 9.51 cm(2)/V·s, a low threshold voltage of 0.99 V, a good subthreshold slope of 135 mV/dec, and an outstanding on/off current ratio of 1.18 × 10(8). In conclusion, by using the microwave-annealed a-IGZO TFT as the transducer in an extended-gate ion-sensitive field-effect transistor biosensor, we developed a high-performance biosensor with excellent sensing properties in terms of pH sensitivity, reliability, and chemical stability.
Perinetti, Giuseppe; Contardo, Luca
2017-01-01
Current evidence on the reliability of growth indicators in the identification of the pubertal growth spurt and efficiency of functional treatment for skeletal Class II malocclusion, the timing of which relies on such indicators, is highly controversial. Regarding growth indicators, the hand and wrist (including the sole middle phalanx of the third finger) maturation method and the standing height recording appear to be most reliable. Other methods are subjected to controversies or were showed to be unreliable. Main sources of controversies include use of single stages instead of ossification events and diagnostic reliability conjecturally based on correlation analyses. Regarding evidence on the efficiency of functional treatment, when treated during the pubertal growth spurt, more favorable response is seen in skeletal Class II patients even though large individual responsiveness remains. Main sources of controversies include design of clinical trials, definition of Class II malocclusion, and lack of inclusion of skeletal maturity among the prognostic factors. While no growth indicator may be considered to have a full diagnostic reliability in the identification of the pubertal growth spurt, their use may still be recommended for increasing efficiency of functional treatment for skeletal Class II malocclusion.
2017-01-01
Current evidence on the reliability of growth indicators in the identification of the pubertal growth spurt and efficiency of functional treatment for skeletal Class II malocclusion, the timing of which relies on such indicators, is highly controversial. Regarding growth indicators, the hand and wrist (including the sole middle phalanx of the third finger) maturation method and the standing height recording appear to be most reliable. Other methods are subjected to controversies or were showed to be unreliable. Main sources of controversies include use of single stages instead of ossification events and diagnostic reliability conjecturally based on correlation analyses. Regarding evidence on the efficiency of functional treatment, when treated during the pubertal growth spurt, more favorable response is seen in skeletal Class II patients even though large individual responsiveness remains. Main sources of controversies include design of clinical trials, definition of Class II malocclusion, and lack of inclusion of skeletal maturity among the prognostic factors. While no growth indicator may be considered to have a full diagnostic reliability in the identification of the pubertal growth spurt, their use may still be recommended for increasing efficiency of functional treatment for skeletal Class II malocclusion. PMID:28168195
TCOPPE school environmental audit tool: assessing safety and walkability of school environments.
Lee, Chanam; Kim, Hyung Jin; Dowdy, Diane M; Hoelscher, Deanna M; Ory, Marcia G
2013-09-01
Several environmental audit instruments have been developed for assessing streets, parks and trails, but none for schools. This paper introduces a school audit tool that includes 3 subcomponents: 1) street audit, 2) school site audit, and 3) map audit. It presents the conceptual basis and the development process of this instrument, and the methods and results of the reliability assessments. Reliability tests were conducted by 2 trained auditors on 12 study schools (high-low income and urban-suburban-rural settings). Kappa statistics (categorical, factual items) and ICC (Likert-scale, perceptual items) were used to assess a) interrater, b) test-retest, and c) peak vs. off-peak hour reliability tests. For the interrater reliability test, the average Kappa was 0.839 and the ICC was 0.602. For the test-retest reliability, the average Kappa was 0.903 and the ICC was 0.774. The peak-off peak reliability was 0.801. Rural schools showed the most consistent results in the peak-off peak and test-retest assessments. For interrater tests, urban schools showed the highest ICC, and rural schools showed the highest Kappa. Most items achieved moderate to high levels of reliabilities in all study schools. With proper training, this audit can be used to assess school environments reliably for research, outreach, and policy-support purposes.
Gleason, Philip M; Harris, Jeffrey; Sheean, Patricia M; Boushey, Carol J; Bruemmer, Barbara
2010-03-01
This is the sixth in a series of monographs on research design and analysis. The purpose of this article is to describe and discuss several concepts related to the measurement of nutrition-related characteristics and outcomes, including validity, reliability, and diagnostic tests. The article reviews the methodologic issues related to capturing the various aspects of a given nutrition measure's reliability, including test-retest, inter-item, and interobserver or inter-rater reliability. Similarly, it covers content validity, indicators of absolute vs relative validity, and internal vs external validity. With respect to diagnostic assessment, the article summarizes the concepts of sensitivity and specificity. The hope is that dietetics practitioners will be able to both use high-quality measures of nutrition concepts in their research and recognize these measures in research completed by others. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.
Critical issues in assuring long lifetime and fail-safe operation of optical communications network
NASA Astrophysics Data System (ADS)
Paul, Dilip K.
1993-09-01
Major factors in assuring long lifetime and fail-safe operation in optical communications networks are reviewed in this paper. Reliable functionality to design specifications, complexity of implementation, and cost are the most critical issues. As economics is the driving force to set the goals as well as priorities for the design, development, safe operation, and maintenance schedules of reliable networks, a balance is sought between the degree of reliability enhancement, cost, and acceptable outage of services. Protecting both the link and the network with high reliability components, hardware duplication, and diversity routing can ensure the best network availability. Case examples include both fiber optic and lasercom systems. Also, the state-of-the-art reliability of photonics in space environment is presented.
Martín-Rodríguez, Saúl; Loturco, Irineu; Hunter, Angus M; Rodríguez-Ruiz, David; Munguia-Izquierdo, Diego
2017-12-01
Martín-Rodríguez, S, Loturco, I, Hunter, AM, Rodríguez-Ruiz, D, and Munguia-Izquierdo, D. Reliability and measurement error of tensiomyography to assess mechanical muscle function: A systematic review. J Strength Cond Res 31(12): 3524-3536, 2017-Interest in studying mechanical skeletal muscle function through tensiomyography (TMG) has increased in recent years. This systematic review aimed to (a) report the reliability and measurement error of all TMG parameters (i.e., maximum radial displacement of the muscle belly [Dm], contraction time [Tc], delay time [Td], half-relaxation time [½ Tr], and sustained contraction time [Ts]) and (b) to provide critical reflection on how to perform accurate and appropriate measurements for informing clinicians, exercise professionals, and researchers. A comprehensive literature search was performed of the Pubmed, Scopus, Science Direct, and Cochrane databases up to July 2017. Eight studies were included in this systematic review. Meta-analysis could not be performed because of the low quality of the evidence of some studies evaluated. Overall, the review of the 9 studies involving 158 participants revealed high relative reliability (intraclass correlation coefficient [ICC]) for Dm (0.91-0.99); moderate-to-high ICC for Ts (0.80-0.96), Tc (0.70-0.98), and ½ Tr (0.77-0.93); and low-to-high ICC for Td (0.60-0.98), independently of the evaluated muscles. In addition, absolute reliability (coefficient of variation [CV]) was low for all TMG parameters except for ½ Tr (CV = >20%), whereas measurement error indexes were high for this parameter. In conclusion, this study indicates that 3 of the TMG parameters (Dm, Td, and Tc) are highly reliable, whereas ½ Tr demonstrate insufficient reliability, and thus should not be used in future studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bauer, R.; Ebersberger, B.; Kupfer, C.
SnAg solder bump is one bump type which is used to replace eutectic SnPb bumps. In this work tests have been done to characterize the reliability properties of this bump type. Electromigration (EM) tests, which were accelerated by high current and high temperature and high temperature storage (HTS) tests were performed. It was found that the reliability properties are sensitive to the material combinations in the interconnect stack. The interconnect stack includes substrate pad, pad finish, bump, underbump metallization (UBM) and the chip pad. Therefore separate test groups for SnAg bumps on Cu substrate pads with organic solderability preservative (OSP)more » finish and the identical bumps on pads with Ni/Au finish were used. In this paper the reliability test results and the corresponding failure analysis are presented. Some explanations about the differences in formation of intermetallic compounds (IMCs) are given.« less
Reliability of the Structured Clinical Interview for DSM-5 Sleep Disorders Module.
Taylor, Daniel J; Wilkerson, Allison K; Pruiksma, Kristi E; Williams, Jacob M; Ruggero, Camilo J; Hale, Willie; Mintz, Jim; Organek, Katherine Marczyk; Nicholson, Karin L; Litz, Brett T; Young-McCaughan, Stacey; Dondanville, Katherine A; Borah, Elisa V; Brundige, Antoinette; Peterson, Alan L
2018-03-15
To develop and demonstrate interrater reliability for a Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) Sleep Disorders (SCISD). The SCISD was designed to be a brief, reliable, and valid interview assessment of adult sleep disorders as defined by the DSM-5. A sample of 106 postdeployment active-duty military members seeking cognitive behavioral therapy for insomnia in a randomized clinical trial were assessed with the SCISD prior to treatment to determine eligibility. Audio recordings of these interviews were double-scored for interrater reliability. The interview is 8 pages long, includes 20 to 51 questions, and takes 10 to 20 minutes to administer. Of the nine major disorders included in the SCISD, six had prevalence rates high enough (ie, n ≥ 5) to include in analyses. Cohen kappa coefficient (κ) was used to assess interrater reliability for insomnia, hypersomnolence, obstructive sleep apnea hypopnea (OSAH), circadian rhythm sleep-wake, nightmare, and restless legs syndrome disorders. There was excellent interrater reliability for insomnia (1.0) and restless legs syndrome (0.83); very good reliability for nightmare disorder (0.78) and OSAH (0.73); and good reliability for hypersomnolence (0.50) and circadian rhythm sleep-wake disorders (0.50). The SCISD is a brief, structured clinical interview that is easy for clinicians to learn and use. The SCISD showed moderate to excellent interrater reliability for six of the major sleep disorders in the DSM-5 among active duty military seeking cognitive behavioral therapy for insomnia in a randomized clinical trial. Replication and extension studies are needed. Registry: ClinicalTrials.gov; Title: Comparing Internet and In-Person Brief Cognitive Behavioral Therapy of Insomnia; Identifier: NCT01549899; URL: https://clinicaltrials.gov/ct2/show/NCT01549899. © 2018 American Academy of Sleep Medicine.
Effect of steel structure and defects on reliability of parts of impact mechanisms
NASA Astrophysics Data System (ADS)
Popelyukh, AI; Repin, AA; Alekseev, SE
2018-03-01
The paper discusses selection of materials suitable for manufacturing critical parts of impact mechanisms. It is shown that in order to extend life of parts exposed to high dynamic loading, it is expedient to use medium- and high-carbon alloy-treated steels featuring low impurity with nonmetallic inclusions and high hardening characteristics. Application of thermally untreated parts is undesirable as steel having ferrite–pearlite structure possesses low fatigue strength. Aimed to ensure high reliability of parts with a hardness of 42–55 HRC, steel should be reinforced by thermal treatement with the formation of multicomponent martensite–bainite structure. High-quality production should include defectoscopy and incoming material control.
Kilgus, Stephen P; Riley-Tillman, T Chris; Stichter, Janine P; Schoemann, Alexander M; Bellesheim, Katie
2016-09-01
The purpose of this investigation was to evaluate the reliability of Direct Behavior Ratings-Social Competence (DBR-SC) ratings. Participants included 60 students identified as possessing deficits in social competence, as well as their 23 classroom teachers. Teachers used DBR-SC to complete ratings of 5 student behaviors within the general education setting on a daily basis across approximately 5 months. During this time, each student was assigned to 1 of 2 intervention conditions, including the Social Competence Intervention-Adolescent (SCI-A) and a business-as-usual (BAU) intervention. Ratings were collected across 3 intervention phases, including pre-, mid-, and postintervention. Results suggested DBR-SC ratings were highly consistent across time within each student, with reliability coefficients predominantly falling in the .80 and .90 ranges. Findings further indicated such levels of reliability could be achieved with only a small number of ratings, with estimates varying between 2 and 10 data points. Group comparison analyses further suggested the reliability of DBR-SC ratings increased over time, such that student behavior became more consistent throughout the intervention period. Furthermore, analyses revealed that for 2 of the 5 DBR-SC behavior targets, the increase in reliability over time was moderated by intervention grouping, with students receiving SCI-A demonstrating greater increases in reliability relative to those in the BAU group. Limitations of the investigation as well as directions for future research are discussed herein. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Proceedings of the 25th Project Integration Meeting
NASA Technical Reports Server (NTRS)
Phillips, M.
1985-01-01
Topics addressed include: silicon sheet growth and characterization, silicon material, process development, high-efficiency cells, environmental isolation, engineering sciences, and reliability physics.
NASA Technical Reports Server (NTRS)
Gerke, R. David; Sandor, Mike; Agarwal, Shri; Moor, Andrew F.; Cooper, Kim A.
2000-01-01
Engineers within the commercial and aerospace industries are using trade-off and risk analysis to aid in reducing spacecraft system cost while increasing performance and maintaining high reliability. In many cases, Commercial Off-The-Shelf (COTS) components, which include Plastic Encapsulated Microcircuits (PEMs), are candidate packaging technologies for spacecrafts due to their lower cost, lower weight and enhanced functionality. Establishing and implementing a parts program that effectively and reliably makes use of these potentially less reliable, but state-of-the-art devices, has become a significant portion of the job for the parts engineer. Assembling a reliable high performance electronic system, which includes COTS components, requires that the end user assume a risk. To minimize the risk involved, companies have developed methodologies by which they use accelerated stress testing to assess the product and reduce the risk involved to the total system. Currently, there are no industry standard procedures for accomplishing this risk mitigation. This paper will present the approaches for reducing the risk of using PEMs devices in space flight systems as developed by two independent Laboratories. The JPL procedure involves primarily a tailored screening with accelerated stress philosophy while the APL procedure is primarily, a lot qualification procedure. Both Laboratories successfully have reduced the risk of using the particular devices for their respective systems and mission requirements.
NASA Technical Reports Server (NTRS)
Connolly, J. C.; Alphonse, G. A.; Carlin, D. B.; Ettenberg, M.
1991-01-01
The operating characteristics (power-current, beam divergence, etc.) and reliability assessment of high-power CSP lasers is discussed. The emission wavelength of these lasers was optimized at 860 to 880 nm. The operational characteristics of a new laser, the inverse channel substrate planar (ICSP) laser, grown by metalorganic chemical vapor deposition (MOCVD), is discussed and the reliability assessment of this laser is reported. The highlights of this study include a reduction in the threshold current value for the laser to 15 mA and a degradation rate of less than 2 kW/hr for the lasers operating at 60 mW of peak output power.
Specialty fibers for fiber optic sensor application
NASA Astrophysics Data System (ADS)
Bennett, K.; Koh, J.; Coon, J.; Chien, C. K.; Artuso, A.; Chen, X.; Nolan, D.; Li, M.-J.
2007-09-01
Over the last several years, Fiber Optic Sensor (FOS) applications have seen an increased acceptance in many areas including oil & gas production monitoring, gyroscopes, current sensors, structural sensing and monitoring, and aerospace applications. High level optical and mechanical reliability of optical fiber is necessary to guarantee reliable performance of FOS. In this paper, we review recent research and development activities on new specialty fibers. We discuss fiber design concepts and present both modeling and experimental results. The main approaches to enhancing fiber attributes include new index profile design and fiber coating modification.
Mazaheri, Masood; Negahban, Hossein; Salavati, Mahyar; Sanjari, Mohammad Ali; Parnianpour, Mohamad
2010-09-01
Although the application of nonlinear tools including recurrence quantification analysis (RQA) has increasingly grown in the recent years especially in balance-disordered populations, there have been few studies which determine their measurement properties. Therefore, a methodological study was performed to estimate the intersession and intrasession reliability of some dynamic features provided by RQA for nonlinear analysis of center of pressure (COP) signals recorded during quiet standing in a sample of patients with musculoskeletal disorders (MSDs) including low back pain (LBP), anterior cruciate ligament (ACL) injury and functional ankle instability (FAI). The subjects completed postural measurements with three levels of difficulty (rigid surface-eyes open, rigid surface-eyes closed, and foam surface-eyes closed). Four RQA measures (% recurrence, % determinism, entropy, and trend) were extracted from the recurrence plot. Relative reliability of these measures was assessed using intraclass correlation coefficient and absolute reliability using standard error of measurement and coefficient of variation. % Determinism and entropy were the most reliable features of RQA for the both intersession and intrasession reliability measures. High level of reliability of % determinism and entropy in this preliminary investigation may show their clinical promise for discriminative and evaluative purposes of balance performance. 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
Test-retest reliability of cardinal plane isokinetic hip torque and EMG.
Claiborne, Tina L; Timmons, Mark K; Pincivero, Danny M
2009-10-01
The objective of the present study was to establish test-retest reliability of isokinetic hip torque and prime mover electromyogram (EMG) through the three cardinal planes of motion. Thirteen healthy young adults participated in two experimental sessions, separated by approximately one week. During each session, isokinetic hip torque was evaluated on the Biodex Isokinetic Dynamometer at a velocity of 60 deg/s. Subjects performed three maximal-effort concentric and eccentric contractions, separately, for right and left hip abduction/adduction, flexion/extension, and internal/external rotation. Surface EMGs were sampled from the gluteus maximus, gluteus medius, adductor, medial and lateral hamstring, and rectus femoris muscles during all contractions. Intraclass correlation coefficients (ICC - 2,1) and standard errors of measurement (SEM) were calculated for peak torque for each movement direction and contraction mode, while ICCs were only computed for the EMG data. Motions that demonstrated high torque reliability included concentric hip abduction (right and left), flexion (right and left), extension (right) and internal rotation (right and left), and eccentric hip abduction (left), adduction (left), flexion (right), and extension (right and left) (ICC range=0.81-0.91). Motions with moderate torque reliability included concentric hip adduction (right), extension (left), internal rotation (left), and external rotation (right), and eccentric hip abduction and adduction (right), flexion (left), internal rotation (right and left), and external rotation (right and left) (ICC range=0.49-0.79). The majority of the EMG sampled muscles (n=12 and n=11 for concentric and eccentric contractions, respectively) demonstrated high reliability (ICC=0.81-0.95). Instances of low, or unacceptable, EMG reliability values occurred for the medial hamstring muscle of the left leg (both contraction modes) and the adductor muscle of the right leg during eccentric internal rotation. The major finding revealed high and moderate levels of between-day reliability of isokinetic hip peak torque and prime mover EMG. It is recommended that the day-to-day variability estimates concomitant with acceptable levels of reliability be considered when attempting to objectify intervention effects on hip muscle performance.
Taghipour, Morteza; Mohseni-Bandpei, Mohammad Ali; Behtash, Hamid; Abdollahi, Iraj; Rajabzadeh, Fatemeh; Pourahmadi, Mohammad Reza; Emami, Mahnaz
2018-04-24
Rehabilitative ultrasound (US) imaging is one of the popular methods for investigating muscle morphologic characteristics and dimensions in recent years. The reliability of this method has been investigated in different studies. As studies have been performed with different designs and quality, reported values of rehabilitative US have a wide range. The objective of this study was to systematically review the literature conducted on the reliability of rehabilitative US imaging for the assessment of deep abdominal and lumbar trunk muscle dimensions. The PubMed/MEDLINE, Scopus, Google Scholar, Science Direct, Embase, Physiotherapy Evidence, Ovid, and CINAHL databases were searched to identify original research articles conducted on the reliability of rehabilitative US imaging published from June 2007 to August 2017. The articles were qualitatively assessed; reliability data were extracted; and the methodological quality was evaluated by 2 independent reviewers. Of the 26 included studies, 16 were considered of high methodological quality. Except for 2 studies, all high-quality studies reported intraclass correlation coefficients (ICCs) for intra-rater reliability of 0.70 or greater. Also, ICCs reported for inter-rater reliability in high-quality studies were generally greater than 0.70. Among low-quality studies, reported ICCs ranged from 0.26 to 0.99 and 0.68 to 0.97 for intra- and inter-rater reliability, respectively. Also, the reported standard error of measurement and minimal detectable change for rehabilitative US were generally in an acceptable range. Generally, the results of the reviewed studies indicate that rehabilitative US imaging has good levels of both inter- and intra-rater reliability. © 2018 by the American Institute of Ultrasound in Medicine.
Wang, X; Jiao, Y; Tang, T; Wang, H; Lu, Z
2013-12-19
Intrinsic connectivity networks (ICNs) are composed of spatial components and time courses. The spatial components of ICNs were discovered with moderate-to-high reliability. So far as we know, few studies focused on the reliability of the temporal patterns for ICNs based their individual time courses. The goals of this study were twofold: to investigate the test-retest reliability of temporal patterns for ICNs, and to analyze these informative univariate metrics. Additionally, a correlation analysis was performed to enhance interpretability. Our study included three datasets: (a) short- and long-term scans, (b) multi-band echo-planar imaging (mEPI), and (c) eyes open or closed. Using dual regression, we obtained the time courses of ICNs for each subject. To produce temporal patterns for ICNs, we applied two categories of univariate metrics: network-wise complexity and network-wise low-frequency oscillation. Furthermore, we validated the test-retest reliability for each metric. The network-wise temporal patterns for most ICNs (especially for default mode network, DMN) exhibited moderate-to-high reliability and reproducibility under different scan conditions. Network-wise complexity for DMN exhibited fair reliability (ICC<0.5) based on eyes-closed sessions. Specially, our results supported that mEPI could be a useful method with high reliability and reproducibility. In addition, these temporal patterns were with physiological meanings, and certain temporal patterns were correlated to the node strength of the corresponding ICN. Overall, network-wise temporal patterns of ICNs were reliable and informative and could be complementary to spatial patterns of ICNs for further study. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.
Intrarater Reliability and Other Psychometrics of the Health Promoting Activities Scale (HPAS).
Muskett, Rachel; Bourke-Taylor, Helen; Hewitt, Alana
The Health Promoting Activities Scale (HPAS) measures the self-rated frequency with which adults participate in activities that promote health. We evaluated the internal consistency, construct validity, and intrarater reliability of the HPAS with a cohort of mothers (N = 56) of school-age children. We used an online survey that included the HPAS and measures of mental and physical health. Statistical analysis included intraclass correlation coefficients (ICCs), measurement error, error range, limits of agreement, and minimum detectable change (MDC). The HPAS showed good internal consistency (Cronbach's α = .73). Construct validity was supported by a significant difference in HPAS scores among participants grouped by physical activity level; no other differences were significant. Results included a high aggregate ICC of .90 and an MDC of 5 points. Our evaluation of the HPAS revealed good reliability and stability, suggesting suitability for ongoing evaluation as an outcome measure. Copyright © 2017 by the American Occupational Therapy Association, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeVoto, Douglas J.
2017-10-19
As maximum device temperatures approach 200 °Celsius, continuous operation, sintered silver materials promise to maintain bonds at these high temperatures without excessive degradation rates. A detailed characterization of the thermal performance and reliability of sintered silver materials and processes has been initiated for the next year. Future steps in crack modeling include efforts to simulate crack propagation directly using the extended finite element method (X-FEM), a numerical technique that uses the partition of unity method for modeling discontinuities such as cracks in a system.
NASA Technical Reports Server (NTRS)
White, Mark
2012-01-01
New space missions will increasingly rely on more advanced technologies because of system requirements for higher performance, particularly in instruments and high-speed processing. Component-level reliability challenges with scaled CMOS in spacecraft systems from a bottom-up perspective have been presented. Fundamental Front-end and Back-end processing reliability issues with more aggressively scaled parts have been discussed. Effective thermal management from system-level to the componentlevel (top-down) is a key element in overall design of reliable systems. Thermal management in space systems must consider a wide range of issues, including thermal loading of many different components, and frequent temperature cycling of some systems. Both perspectives (top-down and bottom-up) play a large role in robust, reliable spacecraft system design.
Ratter, Julia; Radlinger, Lorenz; Lucas, Cees
2014-09-01
Are submaximal and maximal exercise tests reliable, valid and acceptable in people with chronic pain, fibromyalgia and fatigue disorders? Systematic review of studies of the psychometric properties of exercise tests. People older than 18 years with chronic pain, fibromyalgia and chronic fatigue disorders. Studies of the measurement properties of tests of physical capacity in people with chronic pain, fibromyalgia or chronic fatigue disorders were included. Studies were required to report: reliability coefficients (intraclass correlation coefficient, alpha reliability coefficient, limits of agreements and Bland-Altman plots); validity coefficients (intraclass correlation coefficient, Spearman's correlation, Kendal T coefficient, Pearson's correlation); or dropout rates. Fourteen studies were eligible: none had low risk of bias, 10 had unclear risk of bias and four had high risk of bias. The included studies evaluated: Åstrand test; modified Åstrand test; Lean body mass-based Åstrand test; submaximal bicycle ergometer test following another protocol other than Åstrand test; 2-km walk test; 5-minute, 6-minute and 10-minute walk tests; shuttle walk test; and modified symptom-limited Bruce treadmill test. None of the studies assessed maximal exercise tests. Where they had been tested, reliability and validity were generally high. Dropout rates were generally acceptable. The 2-km walk test was not recommended in fibromyalgia. Moderate evidence was found for reliability, validity and acceptability of submaximal exercise tests in patients with chronic pain, fibromyalgia or chronic fatigue. There is no evidence about maximal exercise tests in patients with chronic pain, fibromyalgia and chronic fatigue. Copyright © 2014. Published by Elsevier B.V.
Reliability analysis and utilization of PEMs in space application
NASA Astrophysics Data System (ADS)
Jiang, Xiujie; Wang, Zhihua; Sun, Huixian; Chen, Xiaomin; Zhao, Tianlin; Yu, Guanghua; Zhou, Changyi
2009-11-01
More and more plastic encapsulated microcircuits (PEMs) are used in space missions to achieve high performance. Since PEMs are designed for use in terrestrial operating conditions, the successful usage of PEMs in space harsh environment is closely related to reliability issues, which should be considered firstly. However, there is no ready-made methodology for PEMs in space applications. This paper discusses the reliability for the usage of PEMs in space. This reliability analysis can be divided into five categories: radiation test, radiation hardness, screening test, reliability calculation and reliability assessment. One case study is also presented to illuminate the details of the process, in which a PEM part is used in a joint space program Double-Star Project between the European Space Agency (ESA) and China. The influence of environmental constrains including radiation, humidity, temperature and mechanics on the PEM part has been considered. Both Double-Star Project satellites are still running well in space now.
High reliability linear drive device for artificial hearts
NASA Astrophysics Data System (ADS)
Ji, Jinghua; Zhao, Wenxiang; Liu, Guohai; Shen, Yue; Wang, Fangqun
2012-04-01
In this paper, a new high reliability linear drive device, termed as stator-permanent-magnet tubular oscillating actuator (SPM-TOA), is proposed for artificial hearts (AHs). The key is to incorporate the concept of two independent phases into this linear AH device, hence achieving high reliability operation. The fault-tolerant teeth are employed to provide the desired decoupling phases in magnetic circuit. Also, as the magnets and the coils are located in the stator, the proposed SPM-TOA takes the definite advantages of robust mover and direct-drive capability. By using the time-stepping finite element method, the electromagnetic characteristics of the proposed SPM-TOA are analyzed, including magnetic field distributions, flux linkages, back- electromotive forces (back-EMFs) self- and mutual inductances, as well as cogging and thrust forces. The results confirm that the proposed SPM-TOA meets the dimension, weight, and force requirements of the AH drive device.
Factors Influencing the Reliability of the Glasgow Coma Scale: A Systematic Review.
Reith, Florence Cm; Synnot, Anneliese; van den Brande, Ruben; Gruen, Russell L; Maas, Andrew Ir
2017-06-01
The Glasgow Coma Scale (GCS) characterizes patients with diminished consciousness. In a recent systematic review, we found overall adequate reliability across different clinical settings, but reliability estimates varied considerably between studies, and methodological quality of studies was overall poor. Identifying and understanding factors that can affect its reliability is important, in order to promote high standards for clinical use of the GCS. The aim of this systematic review was to identify factors that influence reliability and to provide an evidence base for promoting consistent and reliable application of the GCS. A comprehensive literature search was undertaken in MEDLINE, EMBASE, and CINAHL from 1974 to July 2016. Studies assessing the reliability of the GCS in adults or describing any factor that influences reliability were included. Two reviewers independently screened citations, selected full texts, and undertook data extraction and critical appraisal. Methodological quality of studies was evaluated with the consensus-based standards for the selection of health measurement instruments checklist. Data were synthesized narratively and presented in tables. Forty-one studies were included for analysis. Factors identified that may influence reliability are education and training, the level of consciousness, and type of stimuli used. Conflicting results were found for experience of the observer, the pathology causing the reduced consciousness, and intubation/sedation. No clear influence was found for the professional background of observers. Reliability of the GCS is influenced by multiple factors and as such is context dependent. This review points to the potential for improvement from training and education and standardization of assessment methods, for which recommendations are presented. Copyright © 2017 by the Congress of Neurological Surgeons.
High-temperature pump-motor assembly
NASA Technical Reports Server (NTRS)
Colker, C.; Waldron, W.
1971-01-01
Assembly pumps liquid sodium-potassium /NaK/ eutectic at 950 K for up to 20,000 hours. Design features include - high operating-temperature capability, zero leakage, process fluid lubricant/coolant, insulation system compatible with ionizing radiation environments, and reliability and long life without maintenance.
de la Cámara, Miguel Ángel; Higueras-Fresnillo, Sara; Martinez-Gomez, David; Veiga, Oscar L
2018-05-29
The inter-day reliability of the Intelligent Device for Energy Expenditure and Activity (IDEEA) has not been studied to date. The study purpose was to examine the inter-day variability and reliability on two consecutive days collected with the IDEEA, as well as to predict the number of days needed to provide a reliable estimate of several movement (walking and climbing stairs) and non-movement behaviors (lying, reclining, sitting) and standing in older adults. The sample included 126 older adults (74 women) who wore the IDEEA for 48-h. Results showed low variability between the two days and its reliability was from moderate (ICC=0.34) to high (ICC=0.80) in most of movement and non-movement behaviors analyzed. The Bland-Altman plots showed a high-moderate agreement between days and the Spearman-Brown formula estimated ranged from 1.2 and 9.1 days of monitoring with the IDEEA are needed to achieve ICCs≥0.70 in older adults for sitting and climbing stairs, respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grabaskas, Dave; Brunett, Acacia J.; Bucknor, Matthew
GE Hitachi Nuclear Energy (GEH) and Argonne National Laboratory are currently engaged in a joint effort to modernize and develop probabilistic risk assessment (PRA) techniques for advanced non-light water reactors. At a high level the primary outcome of this project will be the development of next-generation PRA methodologies that will enable risk-informed prioritization of safety- and reliability-focused research and development, while also identifying gaps that may be resolved through additional research. A subset of this effort is the development of a reliability database (RDB) methodology to determine applicable reliability data for inclusion in the quantification of the PRA. The RDBmore » method developed during this project seeks to satisfy the requirements of the Data Analysis element of the ASME/ANS Non-LWR PRA standard. The RDB methodology utilizes a relevancy test to examine reliability data and determine whether it is appropriate to include as part of the reliability database for the PRA. The relevancy test compares three component properties to establish the level of similarity to components examined as part of the PRA. These properties include the component function, the component failure modes, and the environment/boundary conditions of the component. The relevancy test is used to gauge the quality of data found in a variety of sources, such as advanced reactor-specific databases, non-advanced reactor nuclear databases, and non-nuclear databases. The RDB also establishes the integration of expert judgment or separate reliability analysis with past reliability data. This paper provides details on the RDB methodology, and includes an example application of the RDB methodology for determining the reliability of the intermediate heat exchanger of a sodium fast reactor. The example explores a variety of reliability data sources, and assesses their applicability for the PRA of interest through the use of the relevancy test.« less
McCreesh, Karen M; Crotty, James M; Lewis, Jeremy S
2015-03-01
Narrowing of the subacromial space has been noted as a common feature of rotator cuff (RC) tendinopathy. It has been implicated in the development of symptoms and forms the basis for some surgical and rehabilitation approaches. Various radiological methods have been used to measure the subacromial space, which is represented by a two-dimensional measurement of acromiohumeral distance (AHD). A reliable method of measurement could be used to assess the impact of rehabilitation or surgical interventions for RC tendinopathy; however, there are no published reviews assessing the reliability of AHD measurement. The aim of this review was to systematically assess the evidence for the intrarater and inter-rater reliability of radiological methods of measuring AHD, in order to identify the most reliable method for use in RC tendinopathy. An electronic literature search was carried out and studies describing the reliability of any radiological method of measuring AHD in either healthy or RC tendinopathy groups were included. Eighteen studies met the inclusion criteria and were appraised by two reviewers using the Quality Appraisal for reliability Studies checklist. Eight studies were deemed to be of high methodological quality. Study weaknesses included lack of tester blinding, inadequate description of tester experience, lack of inclusion of symptomatic populations, poor reporting of statistical methods and unclear diagnosis. There was strong evidence for the reliability of ultrasound for measuring AHD, with moderate evidence for MRI and CT measures and conflicting evidence for radiographic methods. Overall, there was lack of research in RC tendinopathy populations, with only six studies including participants with shoulder pain. The results support the reliability of ultrasound and CT or MRI for the measurement of AHD; however, more studies in symptomatic populations are required. The reliability of AHD measurement using radiographs has not been supported by the studies reviewed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
A reliability analysis tool for SpaceWire network
NASA Astrophysics Data System (ADS)
Zhou, Qiang; Zhu, Longjiang; Fei, Haidong; Wang, Xingyou
2017-04-01
A SpaceWire is a standard for on-board satellite networks as the basis for future data-handling architectures. It is becoming more and more popular in space applications due to its technical advantages, including reliability, low power and fault protection, etc. High reliability is the vital issue for spacecraft. Therefore, it is very important to analyze and improve the reliability performance of the SpaceWire network. This paper deals with the problem of reliability modeling and analysis with SpaceWire network. According to the function division of distributed network, a reliability analysis method based on a task is proposed, the reliability analysis of every task can lead to the system reliability matrix, the reliability result of the network system can be deduced by integrating these entire reliability indexes in the matrix. With the method, we develop a reliability analysis tool for SpaceWire Network based on VC, where the computation schemes for reliability matrix and the multi-path-task reliability are also implemented. By using this tool, we analyze several cases on typical architectures. And the analytic results indicate that redundancy architecture has better reliability performance than basic one. In practical, the dual redundancy scheme has been adopted for some key unit, to improve the reliability index of the system or task. Finally, this reliability analysis tool will has a directive influence on both task division and topology selection in the phase of SpaceWire network system design.
Branco, Paulo; Seixas, Daniela; Castro, São Luís
2018-03-01
Resting-state fMRI is a well-suited technique to map functional networks in the brain because unlike task-based approaches it requires little collaboration from subjects. This is especially relevant in clinical settings where a number of subjects cannot comply with task demands. Previous studies using conventional scanner fields have shown that resting-state fMRI is able to map functional networks in single subjects, albeit with moderate temporal reliability. Ultra-high resolution (7T) imaging provides higher signal-to-noise ratio and better spatial resolution and is thus well suited to assess the temporal reliability of mapping results, and to determine if resting-state fMRI can be applied in clinical decision making including preoperative planning. We used resting-state fMRI at ultra-high resolution to examine whether the sensorimotor and language networks are reliable over time - same session and one week after. Resting-state networks were identified for all subjects and sessions with good accuracy. Both networks were well delimited within classical regions of interest. Mapping was temporally reliable at short and medium time-scales as demonstrated by high values of overlap in the same session and one week after for both networks. Results were stable independently of data quality metrics and physiological variables. Taken together, these findings provide strong support for the suitability of ultra-high field resting-state fMRI mapping at the single-subject level. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Remote Sensing Applications with High Reliability in Changjiang Water Resource Management
NASA Astrophysics Data System (ADS)
Ma, L.; Gao, S.; Yang, A.
2018-04-01
Remote sensing technology has been widely used in many fields. But most of the applications cannot get the information with high reliability and high accuracy in large scale, especially for the applications using automatic interpretation methods. We have designed an application-oriented technology system (PIR) composed of a series of accurate interpretation techniques,which can get over 85 % correctness in Water Resource Management from the view of photogrammetry and expert knowledge. The techniques compose of the spatial positioning techniques from the view of photogrammetry, the feature interpretation techniques from the view of expert knowledge, and the rationality analysis techniques from the view of data mining. Each interpreted polygon is accurate enough to be applied to the accuracy sensitive projects, such as the Three Gorge Project and the South - to - North Water Diversion Project. In this paper, we present several remote sensing applications with high reliability in Changjiang Water Resource Management,including water pollution investigation, illegal construction inspection, and water conservation monitoring, etc.
Reliability of joint count assessment in rheumatoid arthritis: a systematic literature review.
Cheung, Peter P; Gossec, Laure; Mak, Anselm; March, Lyn
2014-06-01
Joint counts are central to the assessment of rheumatoid arthritis (RA) but reliability is an issue. To evaluate the reliability and agreement of joint counts (intra-observer and inter-observer) by health care professionals (physicians, nurses, and metrologists) and patients in RA, and the impact of training and standardization on joint count reliability through a systematic literature review. Articles reporting joint count reliability or agreement in RA in PubMed, EMBase, and the Cochrane library between 1960 and 2012 were selected. Data were extracted regarding tender joint counts (TJCs) and swollen joint counts (SJCs) derived by physicians, metrologists, or patients for intra-observer and inter-observer reliability. In addition, methods and effects of training or standardization were extracted. Statistics expressing reliability such as intraclass correlation coefficients (ICCs) were extracted. Data analysis was primarily descriptive due to high heterogeneity. Twenty-eight studies on health care professionals (HCP) and 20 studies on patients were included. Intra-observer reliability for TJCs and SJCs was good for HCPs and patients (range of ICC: 0.49-0.98). Inter-observer reliability between HCPs for TJCs was higher than for SJCs (range of ICC: 0.64-0.88 vs. 0.29-0.98). Patient inter-observer reliability with HCPs as comparators was better for TJCs (range of ICC: 0.31-0.91) compared to SJCs (0.16-0.64). Nine studies (7 with HCPs and 2 with patients) evaluated consensus or training, with improvement in reliability of TJCs but conflicting evidence for SJCs. Intra- and inter-observer reliability was high for TJCs for HCPs and patients: among all groups, reliability was better for TJCs than SJCs. Inter-observer reliability of SJCs was poorer for patients than HCPs. Data were inconclusive regarding the potential for training to improve SJC reliability. Overall, the results support further evaluation for patient-reported joint counts as an outcome measure. © 2013 Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Macknick, J.; Miara, A.; Brinkman, G.; Ibanez, E.; Newmark, R. L.
2014-12-01
The reliability of the power sector is highly vulnerable to variability in the availability and temperature of water resources, including those that might result from potential climatic changes or from competition from other users. In the past decade, power plants throughout the United States have had to shut down or curtail generation due to a lack of available water or from elevated water temperatures. These disruptions in power plant performance can have negative impacts on energy security and can be costly to address. Analysis of water-related vulnerabilities requires modeling capabilities with high spatial and temporal resolution. This research provides an innovative approach to energy-water modeling by evaluating the costs and reliability of a power sector region under policy and climate change scenarios that affect water resource availability and temperatures. This work utilizes results from a spatially distributed river water temperature model coupled with a thermoelectric power plant model to provide inputs into an electricity production cost model that operates on a high spatial and temporal resolution. The regional transmission organization ISO-New England, which includes six New England states and over 32 Gigawatts of power capacity, is utilized as a case study. Hydrological data and power plant operations are analyzed over an eleven year period from 2000-2010 under four scenarios that include climate impacts on water resources and air temperatures as well as strict interpretations of regulations that can affect power plant operations due to elevated water temperatures. Results of these model linkages show how the power sector's reliability and economic performance can be affected by changes in water temperatures and water availability. The effective reliability and capacity value of thermal electric generators are quantified and discussed in the context of current as well as potential future water resource characteristics.
The revised Generalized Expectancy for Success Scale: a validity and reliability study.
Hale, W D; Fiedler, L R; Cochran, C D
1992-07-01
The Generalized Expectancy for Success Scale (GESS; Fibel & Hale, 1978) was revised and assessed for reliability and validity. The revised version was administered to 199 college students along with other conceptually related measures, including the Rosenberg Self-Esteem Scale, the Life Orientation Test, and Rotter's Internal-External Locus of Control Scale. One subsample of students also completed the Eysenck Personality Inventory, while another subsample performed a criterion-related task that involved risk taking. Item analysis yielded 25 items with correlations of .45 or higher with the total score. Results indicated high internal consistency and test-retest reliability.
Space Transportation Main Engine
NASA Technical Reports Server (NTRS)
Monk, Jan C.
1992-01-01
The topics are presented in viewgraph form and include the following: Space Transportation Main Engine (STME) definition, design philosophy, robust design, maximum design condition, casting vs. machined and welded forgings, operability considerations, high reliability design philosophy, engine reliability enhancement, low cost design philosophy, engine systems requirements, STME schematic, fuel turbopump, liquid oxygen turbopump, main injector, and gas generator. The major engine components of the STME and the Space Shuttle Main Engine are compared.
NASA Astrophysics Data System (ADS)
Kondo, Yoshihisa; Yomo, Hiroyuki; Yamaguchi, Shinji; Davis, Peter; Miura, Ryu; Obana, Sadao; Sampei, Seiichi
This paper proposes multipoint-to-multipoint (MPtoMP) real-time broadcast transmission using network coding for ad-hoc networks like video game networks. We aim to achieve highly reliable MPtoMP broadcasting using IEEE 802.11 media access control (MAC) that does not include a retransmission mechanism. When each node detects packets from the other nodes in a sequence, the correctly detected packets are network-encoded, and the encoded packet is broadcasted in the next sequence as a piggy-back for its native packet. To prevent increase of overhead in each packet due to piggy-back packet transmission, network coding vector for each node is exchanged between all nodes in the negotiation phase. Each user keeps using the same coding vector generated in the negotiation phase, and only coding information that represents which user signal is included in the network coding process is transmitted along with the piggy-back packet. Our simulation results show that the proposed method can provide higher reliability than other schemes using multi point relay (MPR) or redundant transmissions such as forward error correction (FEC). We also implement the proposed method in a wireless testbed, and show that the proposed method achieves high reliability in a real-world environment with a practical degree of complexity when installed on current wireless devices.
The Reliability of Individualized Load-Velocity Profiles.
Banyard, Harry G; Nosaka, K; Vernon, Alex D; Haff, G Gregory
2017-11-15
This study examined the reliability of peak velocity (PV), mean propulsive velocity (MPV), and mean velocity (MV) in the development of load-velocity profiles (LVP) in the full depth free-weight back squat performed with maximal concentric effort. Eighteen resistance-trained men performed a baseline one-repetition maximum (1RM) back squat trial and three subsequent 1RM trials used for reliability analyses, with 48-hours interval between trials. 1RM trials comprised lifts from six relative loads including 20, 40, 60, 80, 90, and 100% 1RM. Individualized LVPs for PV, MPV, or MV were derived from loads that were highly reliable based on the following criteria: intra-class correlation coefficient (ICC) >0.70, coefficient of variation (CV) ≤10%, and Cohen's d effect size (ES) <0.60. PV was highly reliable at all six loads. Importantly, MPV and MV were highly reliable at 20, 40, 60, 80 and 90% but not 100% 1RM (MPV: ICC=0.66, CV=18.0%, ES=0.10, standard error of the estimate [SEM]=0.04m·s -1 ; MV: ICC=0.55, CV=19.4%, ES=0.08, SEM=0.04m·s -1 ). When considering the reliable ranges, almost perfect correlations were observed for LVPs derived from PV 20-100% (r=0.91-0.93), MPV 20-90% (r=0.92-0.94) and MV 20-90% (r=0.94-0.95). Furthermore, the LVPs were not significantly different (p>0.05) between trials, movement velocities, or between linear regression versus second order polynomial fits. PV 20-100% , MPV 20-90% , and MV 20-90% are reliable and can be utilized to develop LVPs using linear regression. Conceptually, LVPs can be used to monitor changes in movement velocity and employed as a method for adjusting sessional training loads according to daily readiness.
Validity and reliability of a novel measure of activity performance and participation.
Murgatroyd, Phil; Karimi, Leila
2016-01-01
To develop and evaluate an innovative clinician-rated measure, which produces global numerical ratings of activity performance and participation. Repeated measures study with 48 community-dwelling participants investigating clinical sensibility, comprehensiveness, practicality, inter-rater reliability, responsiveness, sensitivity and concurrent validity with Barthel Index. Important clinimetric characteristics including comprehensiveness and ease of use were rated >8/10 by clinicians. Inter-rater reliability was excellent on the summary scores (intraclass correlation of 0.95-0.98). There was good evidence that the new outcome measure distinguished between known high and low functional scoring groups, including both responsiveness to change and sensitivity at the same time point in numerous tests. Concurrent validity with the Barthel Index was fair to high (Spearman Rank Order Correlation 0.32-0.85, p > 0.05). The new measure's summary scores were nearly twice as responsive to change compared with the Barthel Index. Other more detailed data could also be generated by the new measure. The Activity Performance Measure is an innovative outcome instrument that showed good clinimetric qualities in this initial study. Some of the results were strong, given the sample size, and further trial and evaluation is appropriate. Implications for Rehabilitation The Activity Performance Measure is an innovative outcome measure covering activity performance and participation. In an initial evaluation, it showed good clinimetric qualities including responsiveness to change, sensitivity, practicality, clinical sensibility, item coverage, inter-rater reliability and concurrent validity with the Barthel Index. Further trial and evaluation is appropriate.
Sarig Bahat, Hilla; Sprecher, Elliot; Sela, Itamar; Treleaven, Julia
2016-07-01
The use of virtual reality (VR) for assessment and intervention of neck pain has previously been used and shown reliable for cervical range of motion measures. Neck VR enables analysis of task-oriented neck movement by stimulating responsive movements to external stimuli. Therefore, the purpose of this study was to establish inter-tester reliability of neck kinematic measures so that it can be used as a reliable assessment and treatment tool between clinicians. This reliability study included 46 asymptomatic participants, who were assessed using the neck VR system which displayed an interactive VR scenario via a head-mounted device, controlled by neck movements. The objective of the interactive assessment was to hit 16 targets, randomly appearing in four directions, as fast as possible. Each participant was tested twice by two different testers. Good reliability was found of neck motion kinematic measures in flexion, extension, and rotation (0.64-0.93 inter-class correlation). High reliability was shown for peak velocity globally (0.93), in left rotation (0.9), right rotation and extension (0.88), and flexion (0.86). Mean velocity had a good global reliability (0.84), except for left rotation directed movement with moderate reliability (0.68). Minimal detectable change for peak velocity ranged from 41 to 53 °/s, while mean velocity ranged from 20 to 25 °/s. The results suggest high reliability for peak and mean velocity as measured by the interactive Neck VR assessment of neck motion kinematics. VR appears to provide a reliable and more ecologically valid method of cervical motion evaluation than previous conventional methodologies.
150 {mu}A 18F{sup -} target and beam port upgrade for the IBA 18/9 cyclotron
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stokely, M. H.; Peeples, J. L.; Poorman, M. C.
2012-12-19
A high power ({approx}3 kW) target platform has been developed for the IBA 18/9 cyclotron. New designs for the airlock, collimator and target subsystems have been fabricated and deployed. The primary project goal is reliable commercial production of 18F{sup -} at 150 {mu}A or greater, while secondary goals include improving serviceability and extending service intervals relative to OEM systems. Reliable operation in a production environment has been observed at beam currents up to 140 {mu}A. Challenges include ion source lifetime and localized peaking in the beam intensity distribution.
A study of electric transmission lines for use on the lunar surface
NASA Technical Reports Server (NTRS)
Gaustad, Krista L.; Gordon, Lloyd B.; Weber, Jennifer R.
1994-01-01
The sources for electrical power on a lunar base are said to include solar/chemical, nuclear (static conversion), and nuclear (dynamic conversion). The transmission of power via transmission lines is more practical than power beaming or superconducting because of its low cost and reliable, proven technology. Transmission lines must have minimum mass, maximum efficiency, and the ability to operate reliably in the lunar environment. The transmission line design includes conductor material, insulator material, conductor geometry, conductor configuration, line location, waveform, phase selection, and frequency. This presentation oulines the design. Liquid and gaseous dielectrics are undesirable for long term use in the lunar vacuum due to a high probability of loss. Thus, insulation for high voltage transmission line will most likely be solid dielectric or vacuum insulation.
Space Station Freedom power supply commonality via modular design
NASA Technical Reports Server (NTRS)
Krauthamer, S.; Gangal, M. D.; Das, R.
1990-01-01
At mature operations, Space Station Freedom will need more than 2000 power supplies to feed housekeeping and user loads. Advanced technology power supplies from 20 to 250 W have been hybridized for terrestrial, aerospace, and industry applications in compact, efficient, reliable, lightweight packages compatible with electromagnetic interference requirements. The use of these hybridized packages as modules, either singly or in parallel, to satisfy the wide range of user power supply needs for all elements of the station is proposed. Proposed characteristics for the power supplies include common mechanical packaging, digital control, self-protection, high efficiency at full and partial loads, synchronization capability to reduce electromagnetic interference, redundancy, and soft-start capability. The inherent reliability is improved compared with conventional discrete component power supplies because the hybrid circuits use high-reliability components such as ceramic capacitors. Reliability is further improved over conventional supplies because the hybrid packages, which may be treated as a single part, reduce the parts count in the power supply.
Register-Mihalik, Johna K; Guskiewicz, Kevin M; Mihalik, Jason P; Schmidt, Julianne D; Kerr, Zachary Y; McCrea, Michael A
2013-01-01
To provide reliable change confidence intervals for common clinical concussion measures using a healthy sample of collegiate athletes and to apply these reliable change parameters to a sample of concussed collegiate athletes. Two independent samples were included in the study and evaluated on common clinical measures of concussion. The healthy sample included male, collegiate football student-athletes (n = 38) assessed at 2 time points. The concussed sample included college-aged student-athletes (n = 132) evaluated before and after a concussion. Outcome measures included symptom severity scores, Automated Neuropsychological Assessment Metrics throughput scores, and Sensory Organization Test composite scores. Application of the reliable change parameters suggests that a small percentage of concussed participants were impaired on each measure. We identified a low sensitivity of the entire battery (all measures combined) of 50% but high specificity of 96%. Clinicians should be trained in understanding clinical concussion measures and should be aware of evidence suggesting the multifaceted battery is more sensitive than any single measure. Clinicians should be cautioned that sensitivity to balance and neurocognitive impairments was low for each individual measure. Applying the confidence intervals to our injured sample suggests that these measures do not adequately identify postconcussion impairments when used in isolation.
COTS Ceramic Chip Capacitors: An Evaluation of the Parts and Assurance Methodologies
NASA Technical Reports Server (NTRS)
Brusse, Jay A.; Sampson, Michael J.
2004-01-01
Commercial-Off-The-Shelf (COTS) multilayer ceramic chip capacitors (MLCCs) are continually evolving to reduce physical size and increase volumetric efficiency. Designers of high reliability aerospace and military systems are attracted to these attributes of COTS MLCCs and would like to take advantage of them while maintaining the high standards for long-term reliable operation they are accustomed io when selecting military qualified established reliability (MIL-ER) MLCCs. However, MIL-ER MLCCs are not available in the full range of small chip sizes with high capacitance as found in today's COTS MLCCs. The objectives for this evaluation were to assess the long-term performance of small case size COTS MLCCs and to identify effective, lower-cost product assurance methodologies. Fifteen (15) lots of COTS X7R dielectric MLCCs from four (4) different manufacturers and two (2) MIL-ER BX dielectric MLCCs from two (2) of the same manufacturers were evaluated. Both 0805 and 0402 chip sizes were included. Several voltage ratings were tested ranging from a high of 50 volts to a low of 6.3 volts. The evaluation consisted of a comprehensive screening and qualification test program based upon MIL-PRF-55681 (i.e., voltage conditioning, thermal shock, moisture resistance, 2000-hour life test, etc.). In addition, several lot characterization tests were performed including Destructive Physical Analysis (DPA), Highly Accelerated Life Test (HALT) and Dielectric Voltage Breakdown Strength. The data analysis included a comparison of the 2000-hour life test results (used as a metric for long-term performance) relative to the screening and characterization test results. Results of this analysis indicate that the long-term life performance of COTS MLCCs is variable -- some lots perform well, some lots perform poorly. DPA and HALT were found to be promising lot characterization tests to identify substandard COTS MLCC lots prior to conducting more expensive screening and qualification tests. The results indicate that lot- specific screening and qualification are still recommended for high reliability applications. One significant and concerning observation is that MIL- type voltage conditioning (100 hours at twice rated voltage, 125 C) was not an effective screen in removing infant mortality parts for the particular lots of COTS MLCCs evaluated.
beta-Aminoalcohols as Potential Reactivators of Aged Sarin-/Soman-Inhibited Acetylcholinesterase
2017-02-08
This approach includes high - quality quantum mechanical/molecular mechanical calcula- tions, providing reliable reactivation steps and energetics...I. V. Khavrutskii Department of Defense Biotechnology High Performance Computing Software Applications Institute Telemedicine and Advanced...b] Dr. A. Wallqvist Department of Defense Biotechnology High Performance Computing Software Applications Institute Telemedicine and Advanced
Design and implementation of online automatic judging system
NASA Astrophysics Data System (ADS)
Liang, Haohui; Chen, Chaojie; Zhong, Xiuyu; Chen, Yuefeng
2017-06-01
For lower efficiency and poorer reliability in programming training and competition by currently artificial judgment, design an Online Automatic Judging (referred to as OAJ) System. The OAJ system including the sandbox judging side and Web side, realizes functions of automatically compiling and running the tested codes, and generating evaluation scores and corresponding reports. To prevent malicious codes from damaging system, the OAJ system utilizes sandbox, ensuring the safety of the system. The OAJ system uses thread pools to achieve parallel test, and adopt database optimization mechanism, such as horizontal split table, to improve the system performance and resources utilization rate. The test results show that the system has high performance, high reliability, high stability and excellent extensibility.
Highly reliable high-power AlGaAs/GaAs 808 nm diode laser bars
NASA Astrophysics Data System (ADS)
Hülsewede, R.; Schulze, H.; Sebastian, J.; Schröder, D.; Meusel, J.; Hennig, P.
2007-02-01
There are strong demands at the market to increase power and reliability for 808 nm diode laser bars. Responding to this JENOPTIK Diode Lab GmbH developed high performance 808 nm diode laser bars in the AlGaAs/GaAs material system with special emphasis to high power operation and long term stability. Optimization of the epitaxy structure and improvements in the diode laser bar design results in very high slope efficiency of >1.2 W/A, low threshold current and small beam divergence in slow axis direction. Including low serial resistance the overall wall plug efficiency is up to 65% for our 20%, 30% and 50% filling factor 10 mm diode laser bars. With the JENOPTIK Diode Lab cleaving and coating technique the maximum output power is 205 W in CW operation and 377 W in QCW operation (200 μs, 2% duty cycle) for bars with 50% filling factor. These bars mounted on micro channel cooled package are showing a very high reliability of >15.000 h. Mounted on conductive cooled package high power operation at 100 W is demonstrated for more than 5000h.
INFLUENCES OF RESPONSE RATE AND DISTRIBUTION ON THE CALCULATION OF INTEROBSERVER RELIABILITY SCORES
Rolider, Natalie U.; Iwata, Brian A.; Bullock, Christopher E.
2012-01-01
We examined the effects of several variations in response rate on the calculation of total, interval, exact-agreement, and proportional reliability indices. Trained observers recorded computer-generated data that appeared on a computer screen. In Study 1, target responses occurred at low, moderate, and high rates during separate sessions so that reliability results based on the four calculations could be compared across a range of values. Total reliability was uniformly high, interval reliability was spuriously high for high-rate responding, proportional reliability was somewhat lower for high-rate responding, and exact-agreement reliability was the lowest of the measures, especially for high-rate responding. In Study 2, we examined the separate effects of response rate per se, bursting, and end-of-interval responding. Response rate and bursting had little effect on reliability scores; however, the distribution of some responses at the end of intervals decreased interval reliability somewhat, proportional reliability noticeably, and exact-agreement reliability markedly. PMID:23322930
Alyusuf, Raja H; Prasad, Kameshwar; Abdel Satir, Ali M; Abalkhail, Ali A; Arora, Roopa K
2013-01-01
The exponential use of the internet as a learning resource coupled with varied quality of many websites, lead to a need to identify suitable websites for teaching purposes. The aim of this study is to develop and to validate a tool, which evaluates the quality of undergraduate medical educational websites; and apply it to the field of pathology. A tool was devised through several steps of item generation, reduction, weightage, pilot testing, post-pilot modification of the tool and validating the tool. Tool validation included measurement of inter-observer reliability; and generation of criterion related, construct related and content related validity. The validated tool was subsequently tested by applying it to a population of pathology websites. Reliability testing showed a high internal consistency reliability (Cronbach's alpha = 0.92), high inter-observer reliability (Pearson's correlation r = 0.88), intraclass correlation coefficient = 0.85 and κ =0.75. It showed high criterion related, construct related and content related validity. The tool showed moderately high concordance with the gold standard (κ =0.61); 92.2% sensitivity, 67.8% specificity, 75.6% positive predictive value and 88.9% negative predictive value. The validated tool was applied to 278 websites; 29.9% were rated as recommended, 41.0% as recommended with caution and 29.1% as not recommended. A systematic tool was devised to evaluate the quality of websites for medical educational purposes. The tool was shown to yield reliable and valid inferences through its application to pathology websites.
Crystalline-silicon reliability lessons for thin-film modules
NASA Technical Reports Server (NTRS)
Ross, R. G., Jr.
1985-01-01
The reliability of crystalline silicon modules has been brought to a high level with lifetimes approaching 20 years, and excellent industry credibility and user satisfaction. The transition from crystalline modules to thin film modules is comparable to the transition from discrete transistors to integrated circuits. New cell materials and monolithic structures will require new device processing techniques, but the package function and design will evolve to a lesser extent. Although there will be new encapsulants optimized to take advantage of the mechanical flexibility and low temperature processing features of thin films, the reliability and life degradation stresses and mechanisms will remain mostly unchanged. Key reliability technologies in common between crystalline and thin film modules include hot spot heating, galvanic and electrochemical corrosion, hail impact stresses, glass breakage, mechanical fatigue, photothermal degradation of encapsulants, operating temperature, moisture sorption, circuit design strategies, product safety issues, and the process required to achieve a reliable product from a laboratory prototype.
Approach to developing reliable space reactor power systems
NASA Technical Reports Server (NTRS)
Mondt, Jack F.; Shinbrot, Charles H.
1991-01-01
During Phase II, the Engineering Development Phase, the SP-100 Project has defined and is pursuing a new approach to developing reliable power systems. The approach to developing such a system during the early technology phase is described along with some preliminary examples to help explain the approach. Developing reliable components to meet space reactor power system requirements is based on a top-down systems approach which includes a point design based on a detailed technical specification of a 100-kW power system. The SP-100 system requirements implicitly recognize the challenge of achieving a high system reliability for a ten-year lifetime, while at the same time using technologies that require very significant development efforts. A low-cost method for assessing reliability, based on an understanding of fundamental failure mechanisms and design margins for specific failure mechanisms, is being developed as part of the SP-100 Program.
Reliability analysis of single crystal NiAl turbine blades
NASA Technical Reports Server (NTRS)
Salem, Jonathan; Noebe, Ronald; Wheeler, Donald R.; Holland, Fred; Palko, Joseph; Duffy, Stephen; Wright, P. Kennard
1995-01-01
As part of a co-operative agreement with General Electric Aircraft Engines (GEAE), NASA LeRC is modifying and validating the Ceramic Analysis and Reliability Evaluation of Structures algorithm for use in design of components made of high strength NiAl based intermetallic materials. NiAl single crystal alloys are being actively investigated by GEAE as a replacement for Ni-based single crystal superalloys for use in high pressure turbine blades and vanes. The driving force for this research lies in the numerous property advantages offered by NiAl alloys over their superalloy counterparts. These include a reduction of density by as much as a third without significantly sacrificing strength, higher melting point, greater thermal conductivity, better oxidation resistance, and a better response to thermal barrier coatings. The current drawback to high strength NiAl single crystals is their limited ductility. Consequently, significant efforts including the work agreement with GEAE are underway to develop testing and design methodologies for these materials. The approach to validation and component analysis involves the following steps: determination of the statistical nature and source of fracture in a high strength, NiAl single crystal turbine blade material; measurement of the failure strength envelope of the material; coding of statistically based reliability models; verification of the code and model; and modeling of turbine blades and vanes for rig testing.
Birds see the true colours of fruits to live off the fat of the land
Schaefer, H. Martin; Valido, Alfredo; Jordano, Pedro
2014-01-01
Communication is a characteristic of life, but its reliability and basic definition are hotly debated. Theory predicts that trade among mutualists requires high reliability. Here, we show that moderate reliability already allows mutualists to optimize their rewards. The colours of Mediterranean fleshy-fruits indicate lipid rewards (but not other nutrients) to avian seed dispersers on regional and local scales. On the regional scale, fruits with high lipid content were significantly darker and less chromatic than congeners with lower lipid content. On the local scale, two warbler species (Sylvia atricapilla and Sylvia borin) selected fruit colours that were less chromatic, and thereby maximized their intake of lipids—a critical resource during migration and wintering. Crucially, birds were able to maximize lipid rewards with moderate reliability from visual fruit colours (r2 = 0.44–0.60). We suggest that mutualisms require only that any association between the quality and sensory aspects of signallers is learned through multiple, repeated interactions. Because these conditions are often fulfilled, also in social communication systems, we contend that selection on reliability is less intense than hitherto assumed. This may contribute to explaining the extraordinary diversity of signals, including that of plant reproductive displays. PMID:24403330
Rekleiti, Maria; Souliotis, Kyriakos; Sarafis, Pavlos; Kyriazis, Ioannis; Tsironi, Maria
2018-06-01
The present study focuses on studying the validity and reliability of the Greek edition of DQOL-BCI. DQOL-BCI includes 15 questions-elements that are evaluated on a 5-grade scale like Likert and two general form-shapes. The translation process was conducted in conformity with the guidelines of EuroQol group. A non-random sample of 65 people-patients diagnosed with diabetes I and II was selected. The questionnaire that was used to collect the data was the translated version of DQOL-BCI, and included the demographic characteristics of the interviewees. The content validity of DQOL-BCI was re-examined from a team of five experts (expert panel) for qualitative and quantitative performance. The completion of the questionnaire was done via a personal interview. The sample consisted of 58 people (35 men and 23 women, 59.9 ± 10.9 years). The translation of the questionnaire was found appropriate in accordance to the peculiarities of the Greek language and culture. The largest deviation of values is observed in QOL1 (1.71) in comparison to QOL6 (2.98). The difference between the standard deviations is close to 0.6. The statistics results of the tests showed satisfactory content validity and high construct validity, while the high values for Cronbach alpha index (0.95) reveal high reliability and internal consistency. The Greek version of DQOL-BCI has acceptable psychometric properties and appears to demonstrate high internal reliability and satisfactory construct validity, which allows its use as an important tool in evaluating the quality of life of diabetic patients in relation to their health. Copyright © 2018. Published by Elsevier B.V.
Intersession reliability of fMRI activation for heat pain and motor tasks
Quiton, Raimi L.; Keaser, Michael L.; Zhuo, Jiachen; Gullapalli, Rao P.; Greenspan, Joel D.
2014-01-01
As the practice of conducting longitudinal fMRI studies to assess mechanisms of pain-reducing interventions becomes more common, there is a great need to assess the test–retest reliability of the pain-related BOLD fMRI signal across repeated sessions. This study quantitatively evaluated the reliability of heat pain-related BOLD fMRI brain responses in healthy volunteers across 3 sessions conducted on separate days using two measures: (1) intraclass correlation coefficients (ICC) calculated based on signal amplitude and (2) spatial overlap. The ICC analysis of pain-related BOLD fMRI responses showed fair-to-moderate intersession reliability in brain areas regarded as part of the cortical pain network. Areas with the highest intersession reliability based on the ICC analysis included the anterior midcingulate cortex, anterior insula, and second somatosensory cortex. Areas with the lowest intersession reliability based on the ICC analysis also showed low spatial reliability; these regions included pregenual anterior cingulate cortex, primary somatosensory cortex, and posterior insula. Thus, this study found regional differences in pain-related BOLD fMRI response reliability, which may provide useful information to guide longitudinal pain studies. A simple motor task (finger-thumb opposition) was performed by the same subjects in the same sessions as the painful heat stimuli were delivered. Intersession reliability of fMRI activation in cortical motor areas was comparable to previously published findings for both spatial overlap and ICC measures, providing support for the validity of the analytical approach used to assess intersession reliability of pain-related fMRI activation. A secondary finding of this study is that the use of standard ICC alone as a measure of reliability may not be sufficient, as the underlying variance structure of an fMRI dataset can result in inappropriately high ICC values; a method to eliminate these false positive results was used in this study and is recommended for future studies of test–retest reliability. PMID:25161897
The scientific data acquisition system of the GAMMA-400 space project
NASA Astrophysics Data System (ADS)
Bobkov, S. G.; Serdin, O. V.; Gorbunov, M. S.; Arkhangelskiy, A. I.; Topchiev, N. P.
2016-02-01
The description of scientific data acquisition system (SDAS) designed by SRISA for the GAMMA-400 space project is presented. We consider the problem of different level electronics unification: the set of reliable fault-tolerant integrated circuits fabricated on Silicon-on-Insulator 0.25 mkm CMOS technology and the high-speed interfaces and reliable modules used in the space instruments. The characteristics of reliable fault-tolerant very large scale integration (VLSI) technology designed by SRISA for the developing of computation systems for space applications are considered. The scalable net structure of SDAS based on Serial RapidIO interface including real-time operating system BAGET is described too.
Column Grid Array Rework for High Reliability
NASA Technical Reports Server (NTRS)
Mehta, Atul C.; Bodie, Charles C.
2008-01-01
Due to requirements for reduced size and weight, use of grid array packages in space applications has become common place. To meet the requirement of high reliability and high number of I/Os, ceramic column grid array packages (CCGA) were selected for major electronic components used in next MARS Rover mission (specifically high density Field Programmable Gate Arrays). ABSTRACT The probability of removal and replacement of these devices on the actual flight printed wiring board assemblies is deemed to be very high because of last minute discoveries in final test which will dictate changes in the firmware. The questions and challenges presented to the manufacturing organizations engaged in the production of high reliability electronic assemblies are, Is the reliability of the PWBA adversely affected by rework (removal and replacement) of the CGA package? and How many times can we rework the same board without destroying a pad or degrading the lifetime of the assembly? To answer these questions, the most complex printed wiring board assembly used by the project was chosen to be used as the test vehicle, the PWB was modified to provide a daisy chain pattern, and a number of bare PWB s were acquired to this modified design. Non-functional 624 pin CGA packages with internal daisy chained matching the pattern on the PWB were procured. The combination of the modified PWB and the daisy chained packages enables continuity measurements of every soldered contact during subsequent testing and thermal cycling. Several test vehicles boards were assembled, reworked and then thermal cycled to assess the reliability of the solder joints and board material including pads and traces near the CGA. The details of rework process and results of thermal cycling are presented in this paper.
Reliability of risk-adjusted outcomes for profiling hospital surgical quality.
Krell, Robert W; Hozain, Ahmed; Kao, Lillian S; Dimick, Justin B
2014-05-01
Quality improvement platforms commonly use risk-adjusted morbidity and mortality to profile hospital performance. However, given small hospital caseloads and low event rates for some procedures, it is unclear whether these outcomes reliably reflect hospital performance. To determine the reliability of risk-adjusted morbidity and mortality for hospital performance profiling using clinical registry data. A retrospective cohort study was conducted using data from the American College of Surgeons National Surgical Quality Improvement Program, 2009. Participants included all patients (N = 55,466) who underwent colon resection, pancreatic resection, laparoscopic gastric bypass, ventral hernia repair, abdominal aortic aneurysm repair, and lower extremity bypass. Outcomes included risk-adjusted overall morbidity, severe morbidity, and mortality. We assessed reliability (0-1 scale: 0, completely unreliable; and 1, perfectly reliable) for all 3 outcomes. We also quantified the number of hospitals meeting minimum acceptable reliability thresholds (>0.70, good reliability; and >0.50, fair reliability) for each outcome. For overall morbidity, the most common outcome studied, the mean reliability depended on sample size (ie, how high the hospital caseload was) and the event rate (ie, how frequently the outcome occurred). For example, mean reliability for overall morbidity was low for abdominal aortic aneurysm repair (reliability, 0.29; sample size, 25 cases per year; and event rate, 18.3%). In contrast, mean reliability for overall morbidity was higher for colon resection (reliability, 0.61; sample size, 114 cases per year; and event rate, 26.8%). Colon resection (37.7% of hospitals), pancreatic resection (7.1% of hospitals), and laparoscopic gastric bypass (11.5% of hospitals) were the only procedures for which any hospitals met a reliability threshold of 0.70 for overall morbidity. Because severe morbidity and mortality are less frequent outcomes, their mean reliability was lower, and even fewer hospitals met the thresholds for minimum reliability. Most commonly reported outcome measures have low reliability for differentiating hospital performance. This is especially important for clinical registries that sample rather than collect 100% of cases, which can limit hospital case accrual. Eliminating sampling to achieve the highest possible caseloads, adjusting for reliability, and using advanced modeling strategies (eg, hierarchical modeling) are necessary for clinical registries to increase their benchmarking reliability.
Reliability in perceptual analysis of voice quality.
Bele, Irene Velsvik
2005-12-01
This study focuses on speaking voice quality in male teachers (n = 35) and male actors (n = 36), who represent untrained and trained voice users, because we wanted to investigate normal and supranormal voices. In this study, both substantial and methodologic aspects were considered. It includes a method for perceptual voice evaluation, and a basic issue was rater reliability. A listening group of 10 listeners, 7 experienced speech-language therapists, and 3 speech-language therapist students evaluated the voices by 15 vocal characteristics using VA scales. Two sets of voice signals were investigated: text reading (2 loudness levels) and sustained vowel (3 levels). The results indicated a high interrater reliability for most perceptual characteristics. Connected speech was evaluated more reliably, especially at the normal level, but both types of voice signals were evaluated reliably, although the reliability for connected speech was somewhat higher than for vowels. Experienced listeners tended to be more consistent in their ratings than did the student raters. Some vocal characteristics achieved acceptable reliability even with a smaller panel of listeners. The perceptual characteristics grouped in 4 factors reflected perceptual dimensions.
Reliable and redundant FPGA based read-out design in the ATLAS TileCal Demonstrator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akerstedt, Henrik; Muschter, Steffen; Drake, Gary
The Tile Calorimeter at ATLAS [1] is a hadron calorimeter based on steel plates and scintillating tiles read out by PMTs. The current read-out system uses standard ADCs and custom ASICs to digitize and temporarily store the data on the detector. However, only a subset of the data is actually read out to the counting room. The on-detector electronics will be replaced around 2023. To achieve the required reliability the upgraded system will be highly redundant. Here the ASICs will be replaced with Kintex-7 FPGAs from Xilinx. This, in addition to the use of multiple 10 Gbps optical read-out links,more » will allow a full read-out of all detector data. Due to the higher radiation levels expected when the beam luminosity is increased, opportunities for repairs will be less frequent. The circuitry and firmware must therefore be designed for sufficiently high reliability using redundancy and radiation tolerant components. Within a year, a hybrid demonstrator including the new readout system will be installed in one slice of the ATLAS Tile Calorimeter. This will allow the proposed upgrade to be thoroughly evaluated well before the planned 2023 deployment in all slices, especially with regard to long term reliability. Different firmware strategies alongside with their integration in the demonstrator are presented in the context of high reliability protection against hardware malfunction and radiation induced errors.« less
Bazo-Alvarez, Juan Carlos; Bazo-Alvarez, Oscar Alfredo; Aguila, Jeins; Peralta, Frank; Mormontoy, Wilfredo; Bennett, Ian M
2016-01-01
Our aim was to evaluate the psychometric properties of the FACES-III among Peruvian high school students. This is a psychometric cross-sectional study. A probabilistic sampling was applied, defined by three stages: stratum one (school), stratum two (grade) and cluster (section). The participants were 910 adolescent students of both sexes, between 11 and 18 years of age. The instrument was also the object of study: the Olson's FACES-III. The analysis included a review of the structure / construct validity of the measure by factor analysis and assessment of internal consistency (reliability). The real-cohesion scale had moderately high reliability (Ω=.85) while the real-flexibility scale had moderate reliability (Ω=.74). The reliability found for the ideal-cohesion was moderately high (Ω=.89) like for the scale of ideal-flexibility (Ω=.86). Construct validity was confirmed by the goodness of fit of a two factor model (cohesion and flexibility) with 10 items each [Adjusted goodness of fit index (AGFI) = 0.96; Expected Cross Validation Index (ECVI) = 0.87; Normed fit index (NFI) = 0.93; Goodness of fit index (GFI) = 0.97; Root mean square error of approximation (RMSEA) = 0.06]. FACES-III has sufficient reliability and validity to be used in Peruvian adolescents for the purpose of group or individual assessment.
Reliability of the AMA Guides to the Evaluation of Permanent Impairment.
Forst, Linda; Friedman, Lee; Chukwu, Abraham
2010-12-01
AMA's Guides to the Evaluation of Permanent Impairment is used to rate loss of function and determine compensation and ability to work after injury or illness; however, there are few studies that evaluate reliability or construct validity. To evaluate the reliability of the fifth and sixth editions for back injury; to determine best methods for further study. Intra-class correlation coefficients within and between raters were relatively high. There was wider variability for individual cases. Impairment ratings were lower and correlated less well for the sixth edition, though confidence intervals overlapped. The sixth edition may not be an improvement over the fifth. A research agenda should include investigations of reliability and construct validity for different body sites and organ systems along the entire rating scale and among different categories of raters.
FACTOR ANALYSIS OF A SOCIAL SKILLS SCALE FOR HIGH SCHOOL STUDENTS.
Wang, H-Y; Lin, C-K
2015-10-01
The objective of this study was to develop a social skills scale for high school students in Taiwan. This study adopted stratified random sampling. A total of 1,729 high school students were included. The students ranged in age from 16 to 18 years. A Social Skills Scale was developed for this study and was designed for classroom teachers to fill out. The test-retest reliability of this scale was tested by Pearson's correlation coefficient. Exploratory factor analysis was used to determine construct validity. The Social Skills Scale had good overall test-retest reliability of .92, and the internal consistency of the five subscales was above .90. The results of the factor analysis showed that the Social Skills Scale covered the five domains of classroom learning skills, communication skills, individual initiative skills, interaction skills, and job-related social skills, and the five factors explained 68.34% of the variance. Thus, the Social Skills Scale had good reliability and validity and would be applicable to and could be promoted for use in schools.
Takasaki, Hiroshi; Okuyama, Kousuke; Rosedale, Richard
2017-02-01
Mechanical Diagnosis and Therapy (MDT) is used in the treatment of extremity problems. Classifying clinical problems is one method of providing effective treatment to a target population. Classification reliability is a key factor to determine the precise clinical problem and to direct an appropriate intervention. To explore inter-examiner reliability of the MDT classification for extremity problems in three reliability designs: 1) vignette reliability using surveys with patient vignettes, 2) concurrent reliability, where multiple assessors decide a classification by observing someone's assessment, 3) successive reliability, where multiple assessors independently assess the same patient at different times. Systematic review with data synthesis in a quantitative format. Agreement of MDT subgroups was examined using the Kappa value, with the operational definition of acceptable reliability set at ≥ 0.6. The level of evidence was determined considering the methodological quality of the studies. Six studies were included and all studies met the criteria for high quality. Kappa values for the vignette reliability design (five studies) were ≥ 0.7. There was data from two cohorts in one study for the concurrent reliability design and the Kappa values ranged from 0.45 to 1.0. Kappa values for the successive reliability design (data from three cohorts in one study) were < 0.6. The current review found strong evidence of acceptable inter-examiner reliability of MDT classification for extremity problems in the vignette reliability design, limited evidence of acceptable reliability in the concurrent reliability design and unacceptable reliability in the successive reliability design. Copyright © 2017 Elsevier Ltd. All rights reserved.
Guide to Developing High-Quality, Reliable, and Valid Multiple-Choice Assessments
ERIC Educational Resources Information Center
Towns, Marcy H.
2014-01-01
Chemistry faculty members are highly skilled in obtaining, analyzing, and interpreting physical measurements, but often they are less skilled in measuring student learning. This work provides guidance for chemistry faculty from the research literature on multiple-choice item development in chemistry. Areas covered include content, stem, and…
Constraining uncertainties in water supply reliability in a tropical data scarce basin
NASA Astrophysics Data System (ADS)
Kaune, Alexander; Werner, Micha; Rodriguez, Erasmo; de Fraiture, Charlotte
2015-04-01
Assessing the water supply reliability in river basins is essential for adequate planning and development of irrigated agriculture and urban water systems. In many cases hydrological models are applied to determine the surface water availability in river basins. However, surface water availability and variability is often not appropriately quantified due to epistemic uncertainties, leading to water supply insecurity. The objective of this research is to determine the water supply reliability in order to support planning and development of irrigated agriculture in a tropical, data scarce environment. The approach proposed uses a simple hydrological model, but explicitly includes model parameter uncertainty. A transboundary river basin in the tropical region of Colombia and Venezuela with an approximately area of 2100 km² was selected as a case study. The Budyko hydrological framework was extended to consider climatological input variability and model parameter uncertainty, and through this the surface water reliability to satisfy the irrigation and urban demand was estimated. This provides a spatial estimate of the water supply reliability across the basin. For the middle basin the reliability was found to be less than 30% for most of the months when the water is extracted from an upstream source. Conversely, the monthly water supply reliability was high (r>98%) in the lower basin irrigation areas when water was withdrawn from a source located further downstream. Including model parameter uncertainty provides a complete estimate of the water supply reliability, but that estimate is influenced by the uncertainty in the model. Reducing the uncertainty in the model through improved data and perhaps improved model structure will improve the estimate of the water supply reliability allowing better planning of irrigated agriculture and dependable water allocation decisions.
The Importance of Human Reliability Analysis in Human Space Flight: Understanding the Risks
NASA Technical Reports Server (NTRS)
Hamlin, Teri L.
2010-01-01
HRA is a method used to describe, qualitatively and quantitatively, the occurrence of human failures in the operation of complex systems that affect availability and reliability. Modeling human actions with their corresponding failure in a PRA (Probabilistic Risk Assessment) provides a more complete picture of the risk and risk contributions. A high quality HRA can provide valuable information on potential areas for improvement, including training, procedural, equipment design and need for automation.
Systematic review found AMSTAR, but not R(evised)-AMSTAR, to have good measurement properties.
Pieper, Dawid; Buechter, Roland Brian; Li, Lun; Prediger, Barbara; Eikermann, Michaela
2015-05-01
To summarize all available evidence on measurement properties in terms of reliability, validity, and feasibility of the Assessment of Multiple Systematic Reviews (AMSTAR) tool, including R(evised)-AMSTAR. MEDLINE, EMBASE, Psycinfo, and CINAHL were searched for studies containing information on measurement properties of the tools in October 2013. We extracted data on study characteristics and measurement properties. These data were analyzed following measurement criteria. We included 13 studies, four of them were labeled as validation studies. Nine articles dealt with AMSTAR, two articles dealt with R-AMSTAR, and one article dealt with both instruments. In terms of interrater reliability, most items showed a substantial agreement (>0.6). The median intraclass correlation coefficient (ICC) for the overall score of AMSTAR was 0.83 (range 0.60-0.98), indicating a high agreement. In terms of validity, ICCs were very high with all but one ICC lower than 0.8 when the AMSTAR score was compared with scores from other tools. Scoring AMSTAR takes between 10 and 20 minutes. AMSTAR seems to be reliable and valid. Further investigations for systematic reviews of other study designs than randomized controlled trials are needed. R-AMSTAR should be further investigated as evidence for its use is limited and its measurement properties have not been studied sufficiently. In general, test-retest reliability should be investigated in future studies. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Eshleman, R. L.; Meyers, A. P.; Davidson, W. A.; Gortowski, R. C.; Anderson, M. E.
1973-01-01
The development, performance, and test results for the spaceborne magnetic tape transport are discussed. An analytical model of the tape transport was used to optimize its conceptual design. Each of the subsystems was subjected to reliability analyses which included structural integrity, maintenance of system performance within acceptable bounds, and avoidance of fatigue failure. These subsystems were also compared with each other in order to evaluate reliability characteristics. The transport uses no mechanical couplings. Four drive motors, one for each reel and one for each of two capstans, are used in a differential mode. There are two hybrid, spherical, cone tapered-crown rollers for tape guidance. Storage of the magnetic tape is provided by a reel assembly which includes the reel, a reel support structure and bearings, dust seals, and a dc drive motor. A summary of transport test results on tape guidance, flutter, and skew is provided.
Strength Analysis and Reliability Evaluation for Speed Reducers
NASA Astrophysics Data System (ADS)
Tsai, Yuo-Tern; Hsu, Yung-Yuan
2017-09-01
This paper studies the structural stresses of differential drive (DD) and harmonic drive (HD) for design improvement of reducers. The designed principles of the two reducers are reported for function comparison. The critical components of the reducers are constructed for performing motion simulation and stress analysis. DD is designed based on differential displacement of the decelerated gear ring as well as HD on a flexible spline. Finite element method (FEM) is used to analyze the structural stresses including the dynamic properties of the reducers. The stresses including kinematic properties of the two reducers are compared to observe the properties of the designs. The analyzed results are applied to identify the allowable loads of the reducers in use. The reliabilities of the reducers in different loads are further calculated according to the variation of stress. The studied results are useful on engineering analysis and reliability evaluation for designing a speed reducer with high ratios.
Development of a reliable method to assess footwear comfort during running.
Mündermann, Anne; Nigg, Benno M; Stefanyshyn, Darren J; Humble, R Neil
2002-08-01
The purposes of this study were: (a) to determine whether subjects are able to distinguish between differences in footwear with respect to footwear comfort; and (b) to determine how reliably footwear comfort can be assessed using a visual analogue scale (VAS) and a protocol including a control condition during running. Intraclass correlation coefficients (ICCs) between comfort ratings for repeated conditions were high (ICC = 0.799). Differences in comfort ratings between the insert conditions were significant. A paired t-test revealed a significant difference in overall comfort ratings for the control insert when tested after the soft insert compared to when tested after the hard insert (P = 0.008). The results of this study showed that VASs provide a reliable measure to assess footwear comfort during running under the conditions that: (a) a control condition is included; and (b) the average comfort rating of sessions 4-6 is used. Copyright 2002 Elsevier Science B.V.
Reliability of Wearable Inertial Measurement Units to Measure Physical Activity in Team Handball.
Luteberget, Live S; Holme, Benjamin R; Spencer, Matt
2018-04-01
To assess the reliability and sensitivity of commercially available inertial measurement units to measure physical activity in team handball. Twenty-two handball players were instrumented with 2 inertial measurement units (OptimEye S5; Catapult Sports, Melbourne, Australia) taped together. They participated in either a laboratory assessment (n = 10) consisting of 7 team handball-specific tasks or field assessment (n = 12) conducted in 12 training sessions. Variables, including PlayerLoad™ and inertial movement analysis (IMA) magnitude and counts, were extracted from the manufacturers' software. IMA counts were divided into intensity bands of low (1.5-2.5 m·s -1 ), medium (2.5-3.5 m·s -1 ), high (>3.5 m·s -1 ), medium/high (>2.5 m·s -1 ), and total (>1.5 m·s -1 ). Reliability between devices and sensitivity was established using coefficient of variation (CV) and smallest worthwhile difference (SWD). Laboratory assessment: IMA magnitude showed a good reliability (CV = 3.1%) in well-controlled tasks. CV increased (4.4-6.7%) in more-complex tasks. Field assessment: Total IMA counts (CV = 1.8% and SWD = 2.5%), PlayerLoad (CV = 0.9% and SWD = 2.1%), and their associated variables (CV = 0.4-1.7%) showed a good reliability, well below the SWD. However, the CV of IMA increased when categorized into intensity bands (2.9-5.6%). The reliability of IMA counts was good when data were displayed as total, high, or medium/high counts. A good reliability for PlayerLoad and associated variables was evident. The CV of the previously mentioned variables was well below the SWD, suggesting that OptimEye's inertial measurement unit and its software are sensitive for use in team handball.
Hughes, Michael; Tracey, Andrew; Bhushan, Monica; Chakravarty, Kuntal; Denton, Christopher P; Dubey, Shirish; Guiducci, Serena; Muir, Lindsay; Ong, Voon; Parker, Louise; Pauling, John D; Prabu, Athiveeraramapandian; Rogers, Christine; Roberts, Christopher; Herrick, Ariane L
2018-06-01
The reliability of clinician grading of systemic sclerosis-related digital ulcers has been reported to be poor to moderate at best, which has important implications for clinical trial design. The aim of this study was to examine the reliability of new proposed UK Scleroderma Study Group digital ulcer definitions among UK clinicians with an interest in systemic sclerosis. Raters graded (through a custom-built interface) 90 images (80 unique and 10 repeat) of a range of digital lesions collected from patients with systemic sclerosis. Lesions were graded on an ordinal scale of severity: 'no ulcer', 'healed ulcer' or 'digital ulcer'. A total of 23 clinicians - 18 rheumatologists, 3 dermatologists, 1 hand surgeon and 1 specialist rheumatology nurse - completed the study. A total of 2070 (1840 unique + 230 repeat) image gradings were obtained. For intra-rater reliability, across all images, the overall weighted kappa coefficient was high (0.71) and was moderate (0.55) when averaged across individual raters. Overall inter-rater reliability was poor (0.15). Although our proposed digital ulcer definitions had high intra-rater reliability, the overall inter-rater reliability was poor. Our study highlights the challenges of digital ulcer assessment by clinicians with an interest in systemic sclerosis and provides a number of useful insights for future clinical trial design. Further research is warranted to improve the reliability of digital ulcer definition/rating as an outcome measure in clinical trials, including examining the role for objective measurement techniques, and the development of digital ulcer patient-reported outcome measures.
Reliability history of the Apollo guidance computer
NASA Technical Reports Server (NTRS)
Hall, E. C.
1972-01-01
The Apollo guidance computer was designed to provide the computation necessary for guidance, navigation and control of the command module and the lunar landing module of the Apollo spacecraft. The computer was designed using the technology of the early 1960's and the production was completed by 1969. During the development, production, and operational phase of the program, the computer has accumulated a very interesting history which is valuable for evaluating the technology, production methods, system integration, and the reliability of the hardware. The operational experience in the Apollo guidance systems includes 17 computers which flew missions and another 26 flight type computers which are still in various phases of prelaunch activity including storage, system checkout, prelaunch spacecraft checkout, etc. These computers were manufactured and maintained under very strict quality control procedures with requirements for reporting and analyzing all indications of failure. Probably no other computer or electronic equipment with equivalent complexity has been as well documented and monitored. Since it has demonstrated a unique reliability history, it is important to evaluate the techniques and methods which have contributed to the high reliability of this computer.
Preliminary study, analysis and design for a power switch for digital engine actuators
NASA Technical Reports Server (NTRS)
Beattie, E. C.; Zickwolf, H. C., Jr.
1979-01-01
Innovative control configurations using high temperature switches to operate actuator driving solenoids were studied. The impact on engine control system life cycle costs and reliability of electronic control and (ECU) heat dissipation due to power conditioning and interface drivers were addressed. Various power supply and actuation schemes were investigated, including optical signal transmission and electronics on the actuator, engine driven alternator, and inside the ECU. The use of a switching shunt power conditioner results in the most significant decrease in heat dissipation within the ECU. No overall control system reliability improvement is projected by the use of remote high temperature switches for solenoid drivers.
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Boomer, Kristen T.; Scheick, Leif; Lauenstein, Jean-Marie; Casey, Megan; Hammoud, Ahmad
2014-01-01
The power systems for use in NASA space missions must work reliably under harsh conditions including radiation, thermal cycling, and exposure to extreme temperatures. Gallium nitride semiconductors show great promise, but information pertaining to their performance is scarce. Gallium nitride N-channel enhancement-mode field effect transistors made by EPC Corporation in a 2nd generation of manufacturing were exposed to radiation followed by long-term thermal cycling and testing under high temperature reverse bias conditions in order to address their reliability for use in space missions. Result of the experimental work are presented and discussed.
Ross, Sandy A; Rice, Clinton; Von Behren, Kristyn; Meyer, April; Alexander, Rachel; Murfin, Scott
2015-01-01
The purpose of this study was to establish intra-rater, intra-session, and inter-rater, reliability of sagittal plane hip, knee, and ankle angles with and without reflective markers using the GAITRite walkway and single video camera between student physical therapists and an experienced physical therapist. This study included thirty-two healthy participants age 20-59, stratified by age and gender. Participants performed three successful walks with and without markers applied to anatomical landmarks. GAITRite software was used to digitize sagittal hip, knee, and ankle angles at two phases of gait: (1) initial contact; and (2) mid-stance. Intra-rater reliability was more consistent for the experienced physical therapist, regardless of joint or phase of gait. Intra-session reliability was variable, the experienced physical therapist showed moderate to high reliability (intra-class correlation coefficient (ICC) = 0.50-0.89) and the student physical therapist showed very poor to high reliability (ICC = 0.07-0.85). Inter-rater reliability was highest during mid-stance at the knee with markers (ICC = 0.86) and lowest during mid-stance at the hip without markers (ICC = 0.25). Reliability of a single camera system, especially at the knee joint shows promise. Depending on the specific type of reliability, error can be attributed to the testers (e.g. lack of digitization practice and marker placement), participants (e.g. loose fitting clothing) and camera systems (e.g. frame rate and resolution). However, until the camera technology can be upgraded to a higher frame rate and resolution, and the software can be linked to the GAITRite walkway, the clinical utility for pre/post measures is limited.
Langó, Tamás; Róna, Gergely; Hunyadi-Gulyás, Éva; Turiák, Lilla; Varga, Julia; Dobson, László; Várady, György; Drahos, László; Vértessy, Beáta G; Medzihradszky, Katalin F; Szakács, Gergely; Tusnády, Gábor E
2017-02-13
Transmembrane proteins play crucial role in signaling, ion transport, nutrient uptake, as well as in maintaining the dynamic equilibrium between the internal and external environment of cells. Despite their important biological functions and abundance, less than 2% of all determined structures are transmembrane proteins. Given the persisting technical difficulties associated with high resolution structure determination of transmembrane proteins, additional methods, including computational and experimental techniques remain vital in promoting our understanding of their topologies, 3D structures, functions and interactions. Here we report a method for the high-throughput determination of extracellular segments of transmembrane proteins based on the identification of surface labeled and biotin captured peptide fragments by LC/MS/MS. We show that reliable identification of extracellular protein segments increases the accuracy and reliability of existing topology prediction algorithms. Using the experimental topology data as constraints, our improved prediction tool provides accurate and reliable topology models for hundreds of human transmembrane proteins.
Application of Thermo-Mechanical Measurements of Plastic Packages for Reliability Evaluation of PEMS
NASA Technical Reports Server (NTRS)
Sharma, Ashok K.; Teverovsky, Alexander
2004-01-01
Thermo-mechanical analysis (TMA) is typically employed for measurements of the glass transition temperature (Tg) and coefficients of thermal expansion (CTE) in molding compounds used in plastic encapsulated microcircuits (PEMs). Application of TMA measurements directly to PEMs allows anomalies to be revealed in deformation of packages with temperature, and thus indicates possible reliability concerns related to thermo-mechanical integrity and stability of the devices. In this work, temperature dependencies of package deformation were measured in several types of PEMs that failed environmental stress testing including temperature cycling, highly accelerated stress testing (HAST) in humid environments, and bum-in (BI) testing. Comparison of thermo-mechanical characteristics of packages and molding compounds in the failed parts allowed for explanation of the observed failures. The results indicate that TMA of plastic packages might be used for quality evaluation of PEMs intended for high-reliability applications.
Uncertainties in obtaining high reliability from stress-strength models
NASA Technical Reports Server (NTRS)
Neal, Donald M.; Matthews, William T.; Vangel, Mark G.
1992-01-01
There has been a recent interest in determining high statistical reliability in risk assessment of aircraft components. The potential consequences are identified of incorrectly assuming a particular statistical distribution for stress or strength data used in obtaining the high reliability values. The computation of the reliability is defined as the probability of the strength being greater than the stress over the range of stress values. This method is often referred to as the stress-strength model. A sensitivity analysis was performed involving a comparison of reliability results in order to evaluate the effects of assuming specific statistical distributions. Both known population distributions, and those that differed slightly from the known, were considered. Results showed substantial differences in reliability estimates even for almost nondetectable differences in the assumed distributions. These differences represent a potential problem in using the stress-strength model for high reliability computations, since in practice it is impossible to ever know the exact (population) distribution. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability.
Radioistopes to Solar to High Energy Accelerators - Chip-Scale Energy Sources
NASA Astrophysics Data System (ADS)
Lal, Amit
2013-12-01
This talk will present MEMS based power sources that utilize radioisotopes, solar energy, and potentially nuclear energy through advancements in integration of new structures and materials within MEMS. Micro power harvesters can harness power from vibration, radioisotopes, light, sound, and biology may provide pathways to minimize or even eliminate batteries in sensor nodes. In this talk work on radioisotope thin films for MEMS will be include the self-reciprocating cantilever, betavoltaic cells, and high DC voltages. The self-reciprocating cantilever energy harvester allows small commercially viable amounts of radioisotopes to generate mW to Watts of power so that very reliable power sources that last 100s of years are possible. The tradeoffs between reliability and potential stigma with radioisotopes allow one to span a useful design space with reliability as a key parameter. These power sources provide pulsed power at three different time scales using mechanical, RF, and static extraction of energy from collected charge. Multi-use capability, both harvesting radioisotope power and local vibration energy extends the reliability of micro-power sources further.
Validity and reliability of the Utrecht Work Engagement Scale-Student Version in Sri Lanka.
Wickramasinghe, Nuwan Darshana; Dissanayake, Devani Sakunthala; Abeywardena, Gihan Sajiwa
2018-05-04
The present study was aimed at assessing the validity and the reliability of the Sinhala version of the Utrecht Work Engagement Scale-Student Version (UWES-S) among collegiate cycle students in Sri Lanka. The 17-item UWES-S was translated to Sinhala and the judgmental validity was assessed by a multi-disciplinary panel of experts. Construct validity of the UWES-S was appraised by using multi-trait scaling analysis and exploratory factor analysis (EFA) on data obtained from a sample of 194 grade thirteen students in the Kurunegala district, Sri Lanka. Reliability of the UWES-S was assessed by using internal consistency and test-retest reliability. Except for item 13, all other items showed good psychometric properties in judgemental validity, item-convergent validity and item-discriminant validity. EFA using principal component analysis with Oblimin rotation, suggested a three-factor solution (including vigor, dedication and absorption subscales) explaining 65.4% of the total variance for the 16-item UWES-S (with item 13 deleted). All three subscales show high internal consistency with Cronbach's α coefficient values of 0.867, 0.819, and 0.903 and test-retest reliability was high (p < 0.001). Hence, the Sinhala version of the 16-item UWES-S is a valid and a reliable instrument to assess work engagement among collegiate cycle students in Sri Lanka.
High Power Microwave Tube Reliability Study
1976-08-01
Factors . . . . . ................ 67 1. Environmental Factors . . . . . . . . . a. Ground Fixed ...... .......... 67 b. Ground Mobile ...including cube structure and operating parameters as factors in the models but also environment and aplication . Initially, the tubes to be included in...instLllations. Mobile ground based and seagoing systems have minimum restrictions, spacecraft systems the maximum and airborne system Y 6 .*.. restrictionts
Comprehensive clinical assessment in community setting: applicability of the MDS-HC.
Morris, J N; Fries, B E; Steel, K; Ikegami, N; Bernabei, R; Carpenter, G I; Gilgen, R; Hirdes, J P; Topinková, E
1997-08-01
To describe the results of an international trial of the home care version of the MDS assessment and problem identification system (the MDS-HC), including reliability estimates, a comparison of MDS-HC reliabilities with reliabilities of the same items in the MDS 2.0 nursing home assessment instrument, and an examination of the types of problems found in home care clients using the MDS-HC. Independent, dual assessment of clients of home-care agencies by trained clinicians using a draft of the MDS-HC, with additional descriptive data regarding problem profiles for home care clients. Reliability data from dual assessments of 241 randomly selected clients of home care agencies in five countries, all of whom volunteered to test the MDS-HC. Also included are an expanded sample of 780 home care assessments from these countries and 187 dually assessed residents from 21 nursing homes in the United States. The array of MDS-HC assessment items included measures in the following areas: personal items, cognitive patterns, communication/hearing, vision, mood and behavior, social functioning, informal support services, physical functioning, continence, disease diagnoses health conditions and preventive health measures, nutrition/hydration, dental status, skin condition, environmental assessment, service utilization, and medications. Forty-seven percent of the functional, health status, social environment, and service items in the MDS-HC were taken from the MDS 2.0 for nursing homes. For this item set, it is estimated that the average weighted Kappa is .74 for the MDS-HC and .75 for the MDS 2.0. Similarly, high reliability values were found for items newly introduced in the MDS-HC (weighted Kappa = .70). Descriptive findings also characterize the problems of home care clients, with subanalyses within cognitive performance levels. Findings indicate that the core set of items in the MDS 2.0 work equally well in community and nursing home settings. New items are highly reliable. In tandem, these instruments can be used within the international community, assisting and planning care for older adults within a broad spectrum of service settings, including nursing homes and home care programs. With this community-based, second-generation problem and care plan-driven assessment instrument, disability assessment can be performed consistently across the world.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-26
... Operations, Inc., Including On-Site Leased Workers From Reliable Temp Services, Inc., Johnson & Hill Staffing... Golf Ball Operations, Inc., including on-site leased workers from Reliable Temp Services, Inc., and... Reliable Temp Services, Inc., Johnson & Hill Staffing and Apollo Security, Chicopee, Massachusetts, who...
Mission Reliability Estimation for Repairable Robot Teams
NASA Technical Reports Server (NTRS)
Trebi-Ollennu, Ashitey; Dolan, John; Stancliff, Stephen
2010-01-01
A mission reliability estimation method has been designed to translate mission requirements into choices of robot modules in order to configure a multi-robot team to have high reliability at minimal cost. In order to build cost-effective robot teams for long-term missions, one must be able to compare alternative design paradigms in a principled way by comparing the reliability of different robot models and robot team configurations. Core modules have been created including: a probabilistic module with reliability-cost characteristics, a method for combining the characteristics of multiple modules to determine an overall reliability-cost characteristic, and a method for the generation of legitimate module combinations based on mission specifications and the selection of the best of the resulting combinations from a cost-reliability standpoint. The developed methodology can be used to predict the probability of a mission being completed, given information about the components used to build the robots, as well as information about the mission tasks. In the research for this innovation, sample robot missions were examined and compared to the performance of robot teams with different numbers of robots and different numbers of spare components. Data that a mission designer would need was factored in, such as whether it would be better to have a spare robot versus an equivalent number of spare parts, or if mission cost can be reduced while maintaining reliability using spares. This analytical model was applied to an example robot mission, examining the cost-reliability tradeoffs among different team configurations. Particularly scrutinized were teams using either redundancy (spare robots) or repairability (spare components). Using conservative estimates of the cost-reliability relationship, results show that it is possible to significantly reduce the cost of a robotic mission by using cheaper, lower-reliability components and providing spares. This suggests that the current design paradigm of building a minimal number of highly robust robots may not be the best way to design robots for extended missions.
Mau-Moeller, Anett; Gube, Martin; Felser, Sabine; Feldhege, Frank; Weippert, Matthias; Husmann, Florian; Tischer, Thomas; Bader, Rainer; Bruhn, Sven; Behrens, Martin
2017-08-17
To determine intrasession and intersession reliability of strength measurements and hamstrings to quadriceps strength imbalance ratios (H/Q ratios) using the new isoforce dynamometer. Repeated measures. Exercise science laboratory. Thirty healthy subjects (15 females, 15 males, 27.8 years). Coefficient of variation (CV) and intraclass correlation coefficients (ICC) were calculated for (1) strength parameters, that is peak torque, mean work, and mean power for concentric and eccentric maximal voluntary contractions; isometric maximal voluntary torque (IMVT); rate of torque development (RTD), and (2) H/Q ratios, that is conventional concentric, eccentric, and isometric H/Q ratios (Hcon/Qcon at 60 deg/s, 120 deg/s, and 180 deg/s, Hecc/Qecc at -60 deg/s and Hiso/Qiso) and functional eccentric antagonist to concentric agonist H/Q ratios (Hecc/Qcon and Hcon/Qecc). High reliability: CV <10%, ICC >0.90; moderate reliability: CV between 10% and 20%, ICC between 0.80 and 0.90; low reliability: CV >20%, ICC <0.80. (1) Strength parameters: (a) high intrasession reliability for concentric, eccentric, and isometric measurements, (b) moderate-to-high intersession reliability for concentric and eccentric measurements and IMVT, and (c) moderate-to-high intrasession reliability but low intersession reliability for RTD. (2) H/Q ratios: (a) moderate-to-high intrasession reliability for conventional ratios, (b) high intrasession reliability for functional ratios, (c) higher intersession reliability for Hcon/Qcon and Hiso/Qiso (moderate to high) than Hecc/Qecc (low to moderate), and (d) higher intersession reliability for conventional H/Q ratios (low to high) than functional H/Q ratios (low to moderate). The results have confirmed the reliability of strength parameters and the most frequently used H/Q ratios.
Gabriel, Peter E; Volz, Edna; Bergendahl, Howard W; Burke, Sean V; Solberg, Timothy D; Maity, Amit; Hahn, Stephen M
2015-04-01
Incident learning programs have been recognized as cornerstones of safety and quality assurance in so-called high reliability organizations in industries such as aviation and nuclear power. High reliability organizations are distinguished by their drive to continuously identify and proactively address a broad spectrum of latent safety issues. Many radiation oncology institutions have reported on their experience in tracking and analyzing adverse events and near misses but few have incorporated the principles of high reliability into their programs. Most programs have focused on the reporting and retrospective analysis of a relatively small number of significant adverse events and near misses. To advance a large, multisite radiation oncology department toward high reliability, a comprehensive, cost-effective, electronic condition reporting program was launched to enable the identification of a broad spectrum of latent system failures, which would then be addressed through a continuous quality improvement process. A comprehensive program, including policies, work flows, and information system, was designed and implemented, with use of a low reporting threshold to focus on precursors to adverse events. In a 46-month period from March 2011 through December 2014, a total of 8,504 conditions (average, 185 per month, 1 per patient treated, 3.9 per 100 fractions [individual treatments]) were reported. Some 77.9% of clinical staff members reported at least 1 condition. Ninety-eight percent of conditions were classified in the lowest two of four severity levels, providing the opportunity to address conditions before they contribute to adverse events. Results after approximately four years show excellent employee engagement, a sustained rate of reporting, and a focus on low-level issues leading to proactive quality improvement interventions.
Alyusuf, Raja H.; Prasad, Kameshwar; Abdel Satir, Ali M.; Abalkhail, Ali A.; Arora, Roopa K.
2013-01-01
Background: The exponential use of the internet as a learning resource coupled with varied quality of many websites, lead to a need to identify suitable websites for teaching purposes. Aim: The aim of this study is to develop and to validate a tool, which evaluates the quality of undergraduate medical educational websites; and apply it to the field of pathology. Methods: A tool was devised through several steps of item generation, reduction, weightage, pilot testing, post-pilot modification of the tool and validating the tool. Tool validation included measurement of inter-observer reliability; and generation of criterion related, construct related and content related validity. The validated tool was subsequently tested by applying it to a population of pathology websites. Results and Discussion: Reliability testing showed a high internal consistency reliability (Cronbach's alpha = 0.92), high inter-observer reliability (Pearson's correlation r = 0.88), intraclass correlation coefficient = 0.85 and κ =0.75. It showed high criterion related, construct related and content related validity. The tool showed moderately high concordance with the gold standard (κ =0.61); 92.2% sensitivity, 67.8% specificity, 75.6% positive predictive value and 88.9% negative predictive value. The validated tool was applied to 278 websites; 29.9% were rated as recommended, 41.0% as recommended with caution and 29.1% as not recommended. Conclusion: A systematic tool was devised to evaluate the quality of websites for medical educational purposes. The tool was shown to yield reliable and valid inferences through its application to pathology websites. PMID:24392243
NASA Technical Reports Server (NTRS)
Wiener, Earl L.
1988-01-01
The aims and methods of aircraft cockpit automation are reviewed from a human-factors perspective. Consideration is given to the mixed pilot reception of increased automation, government concern with the safety and reliability of highly automated aircraft, the formal definition of automation, and the ground-proximity warning system and accidents involving controlled flight into terrain. The factors motivating automation include technology availability; safety; economy, reliability, and maintenance; workload reduction and two-pilot certification; more accurate maneuvering and navigation; display flexibility; economy of cockpit space; and military requirements.
Requirements for Printed Wiring Boards
NASA Technical Reports Server (NTRS)
1984-01-01
In order to maintain the high standards of the NASA printed wiring programs, this publication: prescribes NASA's requirements for assuring reliable rigid printed wiring boards; describes and incorporates basic considerations necessary to assure reliable rigid printed wiring boards; establishes the supplier's responsibility to train and certify personnel; provides for supplier documentation of the fabrication and inspection procedures to be used for NASA work, including supplier innovations and changes in technology; and provides visual workmanship standards to aid those responsible for determining quality conformance to the established requirements.
Operational present status and reliability analysis of the upgraded EAST cryogenic system
NASA Astrophysics Data System (ADS)
Zhou, Z. W.; Y Zhang, Q.; Lu, X. F.; Hu, L. B.; Zhu, P.
2017-12-01
Since the first commissioning in 2005, the cryogenic system for EAST (Experimental Advanced Superconducting Tokamak) has been cooled down and warmed up for thirteen experimental campaigns. In order to promote the refrigeration efficiencies and reliability, the EAST cryogenic system was upgraded gradually with new helium screw compressors and new dynamic gas bearing helium turbine expanders with eddy current brake to improve the original poor mechanical and operational performance from 2012 to 2015. Then the totally upgraded cryogenic system was put into operation in the eleventh cool-down experiment, and has been operated for the latest several experimental campaigns. The upgraded system has successfully coped with various normal operational modes during cool-down and 4.5 K steady-state operation under pulsed heat load from the tokamak as well as the abnormal fault modes including turbines protection stop. In this paper, the upgraded EAST cryogenic system including its functional analysis and new cryogenic control networks will be presented in detail. Also, its operational present status in the latest cool-down experiments will be presented and the system reliability will be analyzed, which shows a high reliability and low fault rate after upgrade. In the end, some future necessary work to meet the higher reliability requirement for future uninterrupted long-term experimental operation will also be proposed.
The Validity and reliability of the Comprehensive Home Environment Survey (CHES).
Pinard, Courtney A; Yaroch, Amy L; Hart, Michael H; Serrano, Elena L; McFerren, Mary M; Estabrooks, Paul A
2014-01-01
Few comprehensive measures exist to assess contributors to childhood obesity within the home, specifically among low-income populations. The current study describes the modification and psychometric testing of the Comprehensive Home Environment Survey (CHES), an inclusive measure of the home food, physical activity, and media environment related to childhood obesity. The items were tested for content relevance by an expert panel and piloted in the priority population. The CHES was administered to low-income parents of children 5 to 17 years (N = 150), including a subsample of parents a second time and additional caregivers to establish test-retest and interrater reliabilities. Children older than 9 years (n = 95), as well as parents (N = 150) completed concurrent assessments of diet and physical activity behaviors (predictive validity). Analyses and item trimming resulted in 18 subscales and a total score, which displayed adequate internal consistency (α = .74-.92) and high test-retest reliability (r ≥ .73, ps < .01) and interrater reliability (r ≥ .42, ps < .01). The CHES score and a validated screener for the home environment were correlated (r = .37, p < .01; concurrent validity). CHES subscales were significantly correlated with behavioral measures (r = -.20-.55, p < .05; predictive validity). The CHES shows promise as a valid/reliable assessment of the home environment related to childhood obesity, including healthy diet and physical activity.
Total systems design analysis of high performance structures
NASA Technical Reports Server (NTRS)
Verderaime, V.
1993-01-01
Designer-control parameters were identified at interdiscipline interfaces to optimize structural systems performance and downstream development and operations with reliability and least life-cycle cost. Interface tasks and iterations are tracked through a matrix of performance disciplines integration versus manufacturing, verification, and operations interactions for a total system design analysis. Performance integration tasks include shapes, sizes, environments, and materials. Integrity integrating tasks are reliability and recurring structural costs. Significant interface designer control parameters were noted as shapes, dimensions, probability range factors, and cost. Structural failure concept is presented, and first-order reliability and deterministic methods, benefits, and limitations are discussed. A deterministic reliability technique combining benefits of both is proposed for static structures which is also timely and economically verifiable. Though launch vehicle environments were primarily considered, the system design process is applicable to any surface system using its own unique filed environments.
Kwon, Sungjun; Kim, Jeehoon; Kang, Seungwoo; Lee, Youngki; Baek, Hyunjae
2014-01-01
Abstract We propose CardioGuard, a brassiere-based reliable electrocardiogram (ECG) monitoring sensor system, for supporting daily smartphone healthcare applications. It is designed to satisfy two key requirements for user-unobtrusive daily ECG monitoring: reliability of ECG sensing and usability of the sensor. The system is validated through extensive evaluations. The evaluation results showed that the CardioGuard sensor reliably measure the ECG during 12 representative daily activities including diverse movement levels; 89.53% of QRS peaks were detected on average. The questionnaire-based user study with 15 participants showed that the CardioGuard sensor was comfortable and unobtrusive. Additionally, the signal-to-noise ratio test and the washing durability test were conducted to show the high-quality sensing of the proposed sensor and its physical durability in practical use, respectively. PMID:25405527
Reliability Considerations for the Operation of Large Accelerator User Facilities
Willeke, F. J.
2016-01-29
The lecture provides an overview of considerations relevant for achieving highly reliable operation of accelerator based user facilities. The article starts with an overview of statistical reliability formalism which is followed by high reliability design considerations with examples. Finally, the article closes with operational aspects of high reliability such as preventive maintenance and spares inventory.
Improving the reliability of inverter-based welding machines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schiedermayer, M.
1997-02-01
Although inverter-based welding power sources have been available since the late 1980s, many people hesitated to purchase them because of reliability issues. Unfortunately, their hesitancy had a basis, until now. Recent improvements give some inverters a reliability level that approaches that of traditional, transformer-based industrial welding machines, which have a failure rate of about 1%. Acceptance of inverter-based welding machines is important because, for many welding applications, they provide capabilities that solid-state, transformer-based machines cannot deliver. These advantages include enhanced pulsed gas metal arc welding (GMAW-P), lightweight portability, an ultrastable arc, and energy efficiency--all while producing highly aesthetic weld beadsmore » and delivering multiprocess capabilities.« less
Reliability of Source Mechanisms for a Hydraulic Fracturing Dataset
NASA Astrophysics Data System (ADS)
Eyre, T.; Van der Baan, M.
2016-12-01
Non-double-couple components have been inferred for induced seismicity due to fluid injection, yet these components are often poorly constrained due to the acquisition geometry. Likewise non-double-couple components in microseismic recordings are not uncommon. Microseismic source mechanisms provide an insight into the fracturing behaviour of a hydraulically stimulated reservoir. However, source inversion in a hydraulic fracturing environment is complicated by the likelihood of volumetric contributions to the source due to the presence of high pressure fluids, which greatly increases the possible solution space and therefore the non-uniqueness of the solutions. Microseismic data is usually recorded on either 2D surface or borehole arrays of sensors. In many cases, surface arrays appear to constrain source mechanisms with high shear components, whereas borehole arrays tend to constrain more variable mechanisms including those with high tensile components. The abilities of each geometry to constrain the true source mechanisms are therefore called into question.The ability to distinguish between shear and tensile source mechanisms with different acquisition geometries is investigated using synthetic data. For both inversions, both P- and S- wave amplitudes recorded on three component sensors need to be included to obtain reliable solutions. Surface arrays appear to give more reliable solutions due to a greater sampling of the focal sphere, but in reality tend to record signals with a low signal to noise ratio. Borehole arrays can produce acceptable results, however the reliability is much more affected by relative source-receiver locations and source orientation, with biases produced in many of the solutions. Therefore more care must be taken when interpreting results.These findings are taken into account when interpreting a microseismic dataset of 470 events recorded by two vertical borehole arrays monitoring a horizontal treatment well. Source locations and mechanisms are calculated and the results discussed, including the biases caused by the array geometry. The majority of the events are located within the target reservoir, however a small, seemingly disconnected cluster of events appears 100 m above the reservoir.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-12
... maps? What are the public safety and homeland security implications of public disclosure of key network... 13-33] Improving 9-1-1 Reliability; Reliability and Continuity of Communications Networks, Including... improve the reliability and resiliency of the Nation's 9-1-1 networks. The Notice of Proposed Rulemaking...
High reliability and implications for nursing leaders.
Riley, William
2009-03-01
To review high reliability theory and discuss its implications for the nursing leader. A high reliability organization (HRO) is considered that which has measurable near perfect performance for quality and safety. The author has reviewed the literature, discussed research findings that contribute to improving reliability in health care organizations, and makes five recommendations for how nursing leaders can create high reliability organizations. Health care is not a safe industry and unintended patient harm occurs at epidemic levels. Health care can learn from high reliability theory and practice developed in other high-risk industries. Viewed by HRO standards, unintended patient injury in health care is excessively high and quality is distressingly low. HRO theory and practice can be successfully applied in health care using advanced interdisciplinary teamwork training and deliberate process design techniques. Nursing has a primary leadership function for ensuring patient safety and achieving high quality in health care organizations. Learning HRO theory and methods for achieving high reliability is a foremost opportunity for nursing leaders.
Reliability and agreement in student ratings of the class environment.
Nelson, Peter M; Christ, Theodore J
2016-09-01
The current study estimated the reliability and agreement of student ratings of the classroom environment obtained using the Responsive Environmental Assessment for Classroom Teaching (REACT; Christ, Nelson, & Demers, 2012; Nelson, Demers, & Christ, 2014). Coefficient alpha, class-level reliability, and class agreement indices were evaluated as each index provides important information for different interpretations and uses of student rating scale data. Data for 84 classes across 29 teachers in a suburban middle school were sampled to derive reliability and agreement indices for the REACT subscales across 4 class sizes: 25, 20, 15, and 10. All participating teachers were White and a larger number of 6th-grade classes were included (42%) relative to 7th- (33%) or 8th- (23%) grade classes. Teachers were responsible for a variety of content areas, including language arts (26%), science (26%), math (20%), social studies (19%), communications (6%), and Spanish (3%). Coefficient alpha estimates were generally high across all subscales and class sizes (α = .70-.95); class-mean estimates were greatly impacted by the number of students sampled from each class, with class-level reliability values generally falling below .70 when class size was reduced from 25 to 20. Further, within-class student agreement varied widely across the REACT subscales (mean agreement = .41-.80). Although coefficient alpha and test-retest reliability are commonly reported in research with student rating scales, class-level reliability and agreement are not. The observed differences across coefficient alpha, class-level reliability, and agreement indices provide evidence for evaluating students' ratings of the class environment according to their intended use (e.g., differentiating between classes, class-level instructional decisions). (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Salamon, Sarah; Santelmann, Hanno; Franklin, Jeremy; Baethge, Christopher
2018-04-01
Reliability of schizoaffective disorder (SAD) diagnoses is low in adults but unclear in children and adolescents (CAD). We estimate the test-retest reliability of SAD and its key differential diagnoses (schizophrenia, bipolar disorder, and unipolar depression). Systematic literature search of Medline, Embase, and PsycInfo for studies on test-retest reliability of SAD, in CAD. Cohen's kappa was extracted from studies. We performed meta-analysis for kappa, including subgroup and sensitivity analysis (PROSPERO protocol: CRD42013006713). Out of > 4000 records screened, seven studies were included. We estimated kappa values of 0.27 [95%-CI: 0.07 0.47] for SAD, 0.56 [0.29; 0.83] for schizophrenia, 0.64 [0.55; 0.74] for bipolar disorder, and 0.66 [0.52; 0.81] for unipolar depression. In 5/7 studies kappa of SAD was lower than that of schizophrenia; similar trends emerged for bipolar disorder (4/5) and unipolar depression (2/3). Estimates of positive agreement of SAD diagnoses supported these results. The number of studies and patients included is low. The point-estimate of the test-retest reliability of schizoaffective disorder is only fair, and lower than that of its main differential diagnoses. All kappa values under study were lower in children and adolescents samples than those reported for adults. Clinically, schizoaffective disorder should be diagnosed in strict adherence to the operationalized criteria and ought to be re-evaluated regularly. Should larger studies confirm the insufficient reliability of schizoaffective disorder in children and adolescents, the clinical value of the diagnosis is highly doubtful. Copyright © 2017. Published by Elsevier B.V.
Measurement of cochlear length using the 'A' value for cochlea basal diameter: A feasibility study.
Deep, Nicholas L; Howard, Brittany E; Holbert, Sarah O; Hoxworth, Joseph M; Barrs, David M
2017-07-01
To determine whether the cochlea basal diameter (A value) measurement can be consistently and precisely obtained from high-resolution temporal bone imaging for use in cochlear length estimation. A feasibility study at a tertiary referral center was performed using the temporal bone CTs of 40 consecutive patients. The distance from the round window to the lateral wall was measured for each cochlea by two independent reviewers, a neuroradiologist and an otolaryngologist. The interrater reliability was calculated using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. Forty patients (19 males, 21 females) for a total of 80 cochleae were included. Interrater reliability on the same ear had a high level of agreement by both the ICC and the Bland-Altman plot. ICCs were 0.90 (95% CI: 0.82, 0.94) for the left ear and 0.96 (95% CI: 0.92, 0.98) for the right ear. Bland-Altman plot confirmed interrater reliability with all 96% of measurements falling within the 95% limits of agreement. Measurement between the round window and lateral cochlear wall can be consistently and reliably obtained from high-resolution temporal bone CT scans. Thus, it is feasible to utilize this method to estimate the cochlear length of patients undergoing cochlear implantation.
How reliable are Functional Movement Screening scores? A systematic review of rater reliability.
Moran, Robert W; Schneiders, Anthony G; Major, Katherine M; Sullivan, S John
2016-05-01
Several physical assessment protocols to identify intrinsic risk factors for injury aetiology related to movement quality have been described. The Functional Movement Screen (FMS) is a standardised, field-expedient test battery intended to assess movement quality and has been used clinically in preparticipation screening and in sports injury research. To critically appraise and summarise research investigating the reliability of scores obtained using the FMS battery. Systematic literature review. Systematic search of Google Scholar, Scopus (including ScienceDirect and PubMed), EBSCO (including Academic Search Complete, AMED, CINAHL, Health Source: Nursing/Academic Edition), MEDLINE and SPORTDiscus. Studies meeting eligibility criteria were assessed by 2 reviewers for risk of bias using the Quality Appraisal of Reliability Studies checklist. Overall quality of evidence was determined using van Tulder's levels of evidence approach. 12 studies were appraised. Overall, there was a 'moderate' level of evidence in favour of 'acceptable' (intraclass correlation coefficient ≥0.6) inter-rater and intra-rater reliability for composite scores derived from live scoring. For inter-rater reliability of composite scores derived from video recordings there was 'conflicting' evidence, and 'limited' evidence for intra-rater reliability. For inter-rater reliability based on live scoring of individual subtests there was 'moderate' evidence of 'acceptable' reliability (κ≥0.4) for 4 subtests (Deep Squat, Shoulder Mobility, Active Straight-leg Raise, Trunk Stability Push-up) and 'conflicting' evidence for the remaining 3 (Hurdle Step, In-line Lunge, Rotary Stability). This review found 'moderate' evidence that raters can achieve acceptable levels of inter-rater and intra-rater reliability of composite FMS scores when using live ratings. Overall, there were few high-quality studies, and the quality of several studies was impacted by poor study reporting particularly in relation to rater blinding. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Desmeules, François
2016-12-01
Clinicians often rely on physical examination tests to guide them in the diagnostic process of knee disorders. However, reliability of these tests is often overlooked and may influence the consistency of results and overall diagnostic validity. Therefore, the objective of this study was to systematically review evidence on the reliability of physical examination tests for the diagnosis of knee disorders. A structured literature search was conducted in databases up to January 2016. Included studies needed to report reliability measures of at least one physical test for any knee disorder. Methodological quality was evaluated using the QAREL checklist. A qualitative synthesis of the evidence was performed. Thirty-three studies were included with a mean QAREL score of 5.5 ± 0.5. Based on low to moderate quality evidence, the Thessaly test for meniscal injuries reached moderate inter-rater reliability (k = 0.54). Based on moderate to excellent quality evidence, the Lachman for anterior cruciate ligament injuries reached moderate to excellent inter-rater reliability (k = 0.42 to 0.81). Based on low to moderate quality evidence, the Tibiofemoral Crepitus, Joint Line and Patellofemoral Pain/Tenderness, Bony Enlargement and Joint Pain on Movement tests for knee osteoarthritis reached fair to excellent inter-rater reliability (k = 0.29 to 0.93). Based on low to moderate quality evidence, the Lateral Glide, Lateral Tilt, Lateral Pull and Quality of Movement tests for patellofemoral pain reached moderate to good inter-rater reliability (k = 0.49 to 0.73). Many physical tests appear to reach good inter-rater reliability, but this is based on low-quality and conflicting evidence. High-quality research is required to evaluate the reliability of knee physical examination tests. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Cohen, Gerald C. (Inventor); McMann, Catherine M. (Inventor)
1991-01-01
An improved method and system for automatically generating reliability models for use with a reliability evaluation tool is described. The reliability model generator of the present invention includes means for storing a plurality of low level reliability models which represent the reliability characteristics for low level system components. In addition, the present invention includes means for defining the interconnection of the low level reliability models via a system architecture description. In accordance with the principles of the present invention, a reliability model for the entire system is automatically generated by aggregating the low level reliability models based on the system architecture description.
Bipolar Nickel-hydrogen Batteries for Aerospace Applications
NASA Technical Reports Server (NTRS)
Koehler, C. W.; Vanommering, G.; Puester, N. H.; Puglisi, V. J.
1984-01-01
A bipolar nickel-hydrogen battery which effectively addresses all key requirements for a spacecraft power system, including long-term reliability and low mass, is discussed. The design of this battery is discussed in the context of system requirements and nickel-hydrogen battery technology in general. To achieve the ultimate goal of an aerospace application of a bipolar Ni-H2 battery several objectives must be met in the design and development of the system. These objectives include: maximization of reliability and life; high specific energy and energy density; reasonable cost of manufacture, test, and integration; and ease in scaling for growth in power requirements. These basic objectives translate into a number of specific design requirements, which are discussed.
Ramjets and Ramrockets for Military Applications
1982-03-01
course, as shown, a carefully planned development progrme will be necessary. The high reliability which has been demonstrated for the liquid fuelled...space resear6h tes rendered high energy propellants ,a6re interesting. Liquid hydrogen/ liquid oxigen engine - Nowadays, it is a ra,,able high ...feed system, figure 1, includes low and high pressure turbopumps for the liquid hydrogen fuel and liquid oiygen oxidizer. Each-low- pressure fuel
Lövestam, Elin; Orrevall, Ylva; Koochek, Afsaneh; Karlström, Brita; Andersson, Agneta
2014-06-01
Adequate documentation in medical records is important for high-quality health care. Documentation quality is widely studied within nursing, but studies are lacking within dietetic care. The aim of this study was to translate, elaborate and evaluate an audit instrument, based on the four-step Nutrition Care Process model, for documentation of dietetic care in medical records. The audit instrument includes 14 items focused on essential parts of dietetic care and the documentation's clarity and structure. Each item is to be rated 0-1 or 0-2 points, with a maximum total instrument score of 26. A detailed manual was added to facilitate the interpretation and increase the reliability of the instrument. The instrument is based on a similar tool initiated 9 years ago in the United States, which in this study was translated to Swedish and further elaborated. The translated and further elaborated instrument was named Diet-NCP-Audit. Firstly, the content validity of the Diet-NCP-Audit instrument was tested by five experienced dietitians. They rated the relevance and clarity of the included items. After a first rating, minor improvements were made. After the second rating, the Content Validity Indexes were 1.0, and the Clarity Index was 0.98. Secondly, to test the reliability, four dietitians reviewed 20 systematically collected dietetic notes independently using the audit instrument. Before the review, a calibration process was performed. A comparison of the reviews was performed, which resulted in a moderate inter-rater agreement with Krippendorff's α = 0.65-0.67. Grouping the audit results in three levels: lower, medium or higher range, a Krippendorff's α of 0.74 was considered high reliability. Also, an intra-rater reliability test-retest with a 9 weeks interval, performed by one dietitian, showed strong agreement. To conclude, the evaluated audit instrument had high content validity and moderate to high reliability and can be used in auditing documentation of dietetic care. © 2013 Nordic College of Caring Science.
Psychometric evaluation of commonly used game-specific skills tests in rugby: A systematic review
Oorschot, Sander; Chiwaridzo, Matthew; CM Smits-Engelsman, Bouwien
2017-01-01
Objectives To (1) give an overview of commonly used game-specific skills tests in rugby and (2) evaluate available psychometric information of these tests. Methods The databases PubMed, MEDLINE CINAHL and Africa Wide information were systematically searched for articles published between January 1995 and March 2017. First, commonly used game-specific skills tests were identified. Second, the available psychometrics of these tests were evaluated and the methodological quality of the studies assessed using the Consensus-based Standards for the selection of health Measurement Instruments checklist. Studies included in the first step had to report detailed information on the construct and testing procedure of at least one game-specific skill, and studies included in the second step had additionally to report at least one psychometric property evaluating reliability, validity or responsiveness. Results 287 articles were identified in the first step, of which 30 articles met the inclusion criteria and 64 articles were identified in the second step of which 10 articles were included. Reactive agility, tackling and simulated rugby games were the most commonly used tests. All 10 studies reporting psychometrics reported reliability outcomes, revealing mainly strong evidence. However, all studies scored poor or fair on methodological quality. Four studies reported validity outcomes in which mainly moderate evidence was indicated, but all articles had fair methodological quality. Conclusion Game-specific skills tests indicated mainly high reliability and validity evidence, but the studies lacked methodological quality. Reactive agility seems to be a promising domain, but the specific tests need further development. Future high methodological quality studies are required in order to develop valid and reliable test batteries for rugby talent identification. Trial registration number PROSPERO CRD42015029747. PMID:29259812
Grindem, Hege; Eitzen, Ingrid; Snyder-Mackler, Lynn; Risberg, May Arna
2013-01-01
Background Current methods measuring sports activity after anterior cruciate ligament (ACL) injury are commonly restricted to the most knee-demanding sport, and do not consider participation in multiple sports. We therefore developed an online activity survey to prospectively record monthly participation in all major sports relevant to our patient-group. Objective To assess the reliability, content validity, and concurrent validity of the survey, and evaluate if it provided more complete data on sports participation than a routine activity questionnaire. Methods One hundred and forty-five consecutively included ACL-injured patients were eligible for the reliability study. The retest of the online activity survey was performed two days after the test response had been recorded. A subsample of 88 ACL-reconstructed patients were included in the validity study. The ACL-reconstructed patients completed the online activity survey from the first to the twelfth postoperative month, and a routine activity questionnaire 6 and 12 months postoperatively. Results The online activity survey was highly reliable (κ ranging from 0.81 to 1). It contained all the common sports reported on the routine activity questionnaire. There was substantial agreement between the two methods on return to preinjury main sport (κ = 0.71 and 0.74 at 6 and 12 months postoperatively). The online activity survey revealed that a significantly higher number of patients reported to participate in running, cycling and strength training, and patients reported to participate in a greater number of sports. Conclusion The online activity survey is a highly reliable way of recording detailed changes in sports participation after ACL injury. The findings of this study support the content and concurrent validity of the survey, and suggest that the online activity survey can provide more complete data on sports participation than a routine activity questionnaire. PMID:23645830
Grindem, Hege; Eitzen, Ingrid; Snyder-Mackler, Lynn; Risberg, May Arna
2014-05-01
The current methods measuring sports activity after anterior cruciate ligament (ACL) injury are commonly restricted to the most knee-demanding sports, and do not consider participation in multiple sports. We therefore developed an online activity survey to prospectively record the monthly participation in all major sports relevant to our patient-group. To assess the reliability, content validity and concurrent validity of the survey and to evaluate if it provided more complete data on sports participation than a routine activity questionnaire. 145 consecutively included ACL-injured patients were eligible for the reliability study. The retest of the online activity survey was performed 2 days after the test response had been recorded. A subsample of 88 ACL-reconstructed patients was included in the validity study. The ACL-reconstructed patients completed the online activity survey from the first to the 12th postoperative month, and a routine activity questionnaire 6 and 12 months postoperatively. The online activity survey was highly reliable (κ ranging from 0.81 to 1). It contained all the common sports reported on the routine activity questionnaire. There was a substantial agreement between the two methods on return to preinjury main sport (κ=0.71 and 0.74 at 6 and 12 months postoperatively). The online activity survey revealed that a significantly higher number of patients reported to participate in running, cycling and strength training, and patients reported to participate in a greater number of sports. The online activity survey is a highly reliable way of recording detailed changes in sports participation after ACL injury. The findings of this study support the content and concurrent validity of the survey, and suggest that the online activity survey can provide more complete data on sports participation than a routine activity questionnaire.
Environmental change mediates mate choice for an extended phenotype, but not for mate quality.
Head, Megan L; Fox, Rebecca J; Barber, Iain
2017-01-01
Sexual cues, including extended phenotypes, are expected to be reliable indicators of male genetic quality and/or provide information on parental quality. However, the reliability of these cues may be dependent on stability of the environment, with heterogeneity affecting how selection acts on such traits. Here, we test how environmental change mediates mate choice for multiple sexual traits, including an extended phenotype--the structure of male-built nests - in stickleback fish. First, we manipulated the dissolved oxygen (DO) content of water to create high or low DO environments in which male fish built nests. Then we recorded the mate choice of females encountering these males (and their nests), under either the same or reversed DO conditions. Males in high DO environments built more compact nests than those in low DO conditions and males adjusted their nest structure in response to changing conditions. Female mate choice for extended phenotype (male nests) was environmentally dependent (females chose more compact nests in high DO conditions), while female choice for male phenotype was not (females chose large, vigorous males regardless of DO level). Examining mate choice in this dynamic context suggests that females evaluate the reliability of multiple sexual cues, taking into account environmental heterogeneity. © 2016 The Author(s). Evolution published by Wiley Periodicals, Inc. on behalf of The Society for the Study of Evolution.
Advanced Stirling Convertor Heater Head Durability and Reliability Quantification
NASA Technical Reports Server (NTRS)
Krause, David L.; Shah, Ashwin R.; Korovaichuk, Igor; Kalluri, Sreeramesh
2008-01-01
The National Aeronautics and Space Administration (NASA) has identified the high efficiency Advanced Stirling Radioisotope Generator (ASRG) as a candidate power source for long duration Science missions, such as lunar applications, Mars rovers, and deep space missions, that require reliable design lifetimes of up to 17 years. Resistance to creep deformation of the MarM-247 heater head (HH), a structurally critical component of the ASRG Advanced Stirling Convertor (ASC), under high temperatures (up to 850 C) is a key design driver for durability. Inherent uncertainties in the creep behavior of the thin-walled HH and the variations in the wall thickness, control temperature, and working gas pressure need to be accounted for in the life and reliability prediction. Due to the availability of very limited test data, assuring life and reliability of the HH is a challenging task. The NASA Glenn Research Center (GRC) has adopted an integrated approach combining available uniaxial MarM-247 material behavior testing, HH benchmark testing and advanced analysis in order to demonstrate the integrity, life and reliability of the HH under expected mission conditions. The proposed paper describes analytical aspects of the deterministic and probabilistic approaches and results. The deterministic approach involves development of the creep constitutive model for the MarM-247 (akin to the Oak Ridge National Laboratory master curve model used previously for Inconel 718 (Special Metals Corporation)) and nonlinear finite element analysis to predict the mean life. The probabilistic approach includes evaluation of the effect of design variable uncertainties in material creep behavior, geometry and operating conditions on life and reliability for the expected life. The sensitivity of the uncertainties in the design variables on the HH reliability is also quantified, and guidelines to improve reliability are discussed.
ERIC Educational Resources Information Center
Jones, Corinne A.; Hoffman, Matthew R.; Geng, Zhixian; Abdelhalim, Suzan M.; Jiang, Jack J.; McCulloch, Timothy M.
2014-01-01
Purpose: The purpose of this study was to investigate inter- and intrarater reliability among expert users, novice users, and speech-language pathologists with a semiautomated high-resolution manometry analysis program. We hypothesized that all users would have high intrarater reliability and high interrater reliability. Method: Three expert…
NASA Astrophysics Data System (ADS)
Qiang, Tian; Wang, Cong; Kim, Nam-Young
2017-08-01
A diplexer offering the advantages of compact size, high performance, and high reliability is proposed on the basis of advanced integrated passive device (IPD) fabrication techniques. The proposed diplexer is developed by combining a third-order low-pass filter (LPF) and a third-order high-pass filter (HPF), which are designed on the basis of the elliptic function prototype low-pass filter. Primary components, such as inductors and capacitors, are designed and fabricated with high Q-factor and appropriate values, and they are subsequently used to construct a compact diplexer having a chip area of 900 μm × 1100 μm (0.009 λ0 × 0.011 λ0, where λ0 is the guided wavelength). In addition, a small-outline transistor (SOT-6) packaging method is adopted, and reliability tests (including temperature, humidity, vibration, and pressure) are conducted to guarantee long-term stability and commercial success. The packaged measurement results indicate excellent RF performance with insertion losses of 1.39 dB and 0.75 dB at operation bands of 0.9 GHz and 1.8 GHz, respectively. The return loss is lower than 10 dB from 0.5 GHz to 4.0 GHz, while the isolation is higher than 15 dB from 0.5 GHz to 3.0 GHz. Thus, it can be concluded that the proposed SOT-6 packaged diplexer is a promising candidate for GSM/CDMA applications. Synthetic solution of diplexer design, RF performance optimization, fabrication process, packaging, RF response measurement, and reliability test is particularly explained and analyzed in this work.
Commercial Parts Technology Qualification Processes
NASA Technical Reports Server (NTRS)
Cooper, Mark S.
2013-01-01
Many high-reliability systems, including space systems, use selected commercial parts (including Plastic Encapsulated Microelectronics or PEMs) for unique functionality, small size, low weight, high mechanical shock resistance, and other factors. Predominantly this usage is subjected to certain 100% tests (typically called screens) and certain destructive tests usually (but not always) performed on the flight lot (typically called qualification tests). Frequently used approaches include those documented in EEE-INST-002 and JPL DocID62212 (which are sometimes modified by the particular aerospace space systems manufacturer). In this study, approaches from these documents and several space systems manufacturers are compared to approaches from a launch systems manufacturer (SpaceX), an implantable medical electronics manufacturer (Medtronics), and a high-reliability transport system process (automotive systems). In the conclusions section, these processes are outlined for all of these cases and presented in tabular form. Then some simple comparisons are made. In this introduction section, the PEM technology qualification process is described, as documented in EEE-INST-002 (written by the Goddard Space Flight Center, GSFC), as well as the somewhat modified approach employed at the Jet Propulsion Laboratory (JPL). Approaches used at several major NASA contractors are also described
Rating scales for dystonia in cerebral palsy: reliability and validity.
Monbaliu, E; Ortibus, E; Roelens, F; Desloovere, K; Deklerck, J; Prinzie, P; de Cock, P; Feys, H
2010-06-01
This study investigated the reliability and validity of the Barry-Albright Dystonia Scale (BADS), the Burke-Fahn-Marsden Movement Scale (BFMMS), and the Unified Dystonia Rating Scale (UDRS) in patients with bilateral dystonic cerebral palsy (CP). Three raters independently scored videotapes of 10 patients (five males, five females; mean age 13 y 3 mo, SD 5 y 2 mo, range 5-22 y). One patient each was classified at levels I-IV in the Gross Motor Function Classification System and six patients were classified at level V. Reliability was measured by (1) intraclass correlation coefficient (ICC) for interrater reliability, (2) standard error of measurement (SEM) and smallest detectable difference (SDD), and (3) Cronbach's alpha for internal consistency. Validity was assessed by Pearson's correlations among the three scales used and by content analysis. Moderate to good interrater reliability was found for total scores of the three scales (ICC: BADS=0.87; BFMMS=0.86; UDRS=0.79). However, many subitems showed low reliability, in particular for the UDRS. SEM and SDD were respectively 6.36% and 17.72% for the BADS, 9.88% and 27.39% for the BFMMS, and 8.89% and 24.63% for the UDRS. High internal consistency was found. Pearson's correlations were high. Content validity showed insufficient accordance with the new CP definition and classification. Our results support the internal consistency and concurrent validity of the scales; however, taking into consideration the limitations in reliability, including the large SDD values and the content validity, further research on methods of assessment of dystonia is warranted.
Implications of scaling on static RAM bit cell stability and reliability
NASA Astrophysics Data System (ADS)
Coones, Mary Ann; Herr, Norm; Bormann, Al; Erington, Kent; Soorholtz, Vince; Sweeney, John; Phillips, Michael
1993-01-01
In order to lower manufacturing costs and increase performance, static random access memory (SRAM) bit cells are scaled progressively toward submicron geometries. The reliability of an SRAM is highly dependent on the bit cell stability. Smaller memory cells with less capacitance and restoring current make the array more susceptible to failures from defectivity, alpha hits, and other instabilities and leakage mechanisms. Improving long term reliability while migrating to higher density devices makes the task of building in and improving reliability increasingly difficult. Reliability requirements for high density SRAMs are very demanding with failure rates of less than 100 failures per billion device hours (100 FITs) being a common criteria. Design techniques for increasing bit cell stability and manufacturability must be implemented in order to build in this level of reliability. Several types of analyses are performed to benchmark the performance of the SRAM device. Examples of these analysis techniques which are presented here include DC parametric measurements of test structures, functional bit mapping of the circuit used to characterize the entire distribution of bits, electrical microprobing of weak and/or failing bits, and system and accelerated soft error rate measurements. These tests allow process and design improvements to be evaluated prior to implementation on the final product. These results are used to provide comprehensive bit cell characterization which can then be compared to device models and adjusted accordingly to provide optimized cell stability versus cell size for a particular technology. The result is designed in reliability which can be accomplished during the early stages of product development.
Rose, G; Mulder, H A; Thompson, A N; van der Werf, J H J; van Arendonk, J A M
2015-08-01
Breeding programmes for livestock require economic weights for traits that reflect the most profitable animal in a given production system, which affect the response in each trait after selection. The profitability of sheep production systems is affected by changes in pasture growth as well as grain, meat and wool prices between seasons and across years. Annual pasture growth varies between regions within Australia's Mediterranean climate zone from low growth with long periods of drought to high growth with shorter periods of drought. Therefore, the objective of this study was to assess whether breeding objectives need to be adapted for regions, depending on how reliable the pasture growth is across years. We modelled farms with Merino sheep bred for wool and meat in 10 regions in Western Australia. Across these 10 regions, mean annual pasture growth decreased, and the CV of annual pasture growth increased as pasture growth for regions became less reliable. We calculated economic values for nine traits, optimising management across 11 years, including variation for pasture growth and wool, meat and grain prices between and within years from 2002 to 2012. These economic values were used to calculate responses to selection for each trait for the 10 regions. We identified two potential breeding objectives, one for regions with low or high reliability and the other for regions with medium reliability of pasture growth. Breeding objectives for high or low pasture growth reliability had more emphasis on live weight traits and number of lambs weaned. Breeding objectives for medium reliability of pasture growth had more emphasis on decreasing fibre diameter. Relative economic weights for fleece weight did not change across the regions. Regions with low or high pasture reliability had similar breeding objectives and response to selection, because the relationship between the economic values and CV of pasture growth were not linear for live weight traits and the number of lambs weaned. This non-linearity was caused by differences in distribution of pasture growth between regions, particularly during summer and autumn, when ewes were pregnant, with increases in energy requirements affecting the value of lambs weaned. In addition, increasing live weight increased the intake capacity of sheep, which meant that more poor quality pasture could be consumed during summer and autumn, which had more value in regions with low and high pasture reliability. We concluded that breeding values for sheep production systems should be customised depending on the reliability of pasture growth between years.
Low-Frequency Fluctuations of the Resting Brain: High Magnitude Does Not Equal High Reliability
Jia, Wenbin; Liao, Wei; Li, Xun; Huang, Huiyuan; Yuan, Jianhua; Zang, Yu-Feng; Zhang, Han
2015-01-01
The amplitude of low-frequency fluctuation (ALFF) measures low-frequency oscillations of the blood-oxygen-level-dependent signal, characterizing local spontaneous activity during the resting state. ALFF is a commonly used measure for resting-state functional magnetic resonance imaging (rs-fMRI) in numerous basic and clinical neuroscience studies. Using a test-retest rs-fMRI dataset consisting of 21 healthy subjects and three repetitive scans, we found that several key brain regions with high ALFF intensities (or magnitude) had poor reliability. Such regions included the posterior cingulate cortex, the medial prefrontal cortex in the default mode network, parts of the right and left thalami, and the primary visual and motor cortices. The above finding was robust with regard to different sample sizes (number of subjects), different scanning parameters (repetition time) and variations of test-retest intervals (i.e., intra-scan, intra-session, and inter-session reliability), as well as with different scanners. Moreover, the qualitative, map-wise results were validated further with a region-of-interest-based quantitative analysis using “canonical” coordinates as reported previously. Therefore, we suggest that the reliability assessments be incorporated in future ALFF studies, especially for the brain regions with a large ALFF magnitude as listed in our paper. Splitting single data into several segments and assessing within-scan “test-retest” reliability is an acceptable alternative if no “real” test-retest datasets are available. Such evaluations might become more necessary if the data are collected with clinical scanners whose performance is not as good as those that are used for scientific research purposes and are better maintained because the lower signal-to-noise ratio may further dampen ALFF reliability. PMID:26053265
Human Reliability and the Cost of Doing Business
NASA Technical Reports Server (NTRS)
DeMott, Diana
2014-01-01
Most businesses recognize that people will make mistakes and assume errors are just part of the cost of doing business, but does it need to be? Companies with high risk, or major consequences, should consider the effect of human error. In a variety of industries, Human Errors have caused costly failures and workplace injuries. These have included: airline mishaps, medical malpractice, administration of medication and major oil spills have all been blamed on human error. A technique to mitigate or even eliminate some of these costly human errors is the use of Human Reliability Analysis (HRA). Various methodologies are available to perform Human Reliability Assessments that range from identifying the most likely areas for concern to detailed assessments with human error failure probabilities calculated. Which methodology to use would be based on a variety of factors that would include: 1) how people react and act in different industries, and differing expectations based on industries standards, 2) factors that influence how the human errors could occur such as tasks, tools, environment, workplace, support, training and procedure, 3) type and availability of data and 4) how the industry views risk & reliability influences ( types of emergencies, contingencies and routine tasks versus cost based concerns). The Human Reliability Assessments should be the first step to reduce, mitigate or eliminate the costly mistakes or catastrophic failures. Using Human Reliability techniques to identify and classify human error risks allows a company more opportunities to mitigate or eliminate these risks and prevent costly failures.
NASA Astrophysics Data System (ADS)
Tsanakas, John A.; Jaffre, Damien; Sicre, Mathieu; Elouamari, Rachid; Vossier, Alexis; de Salins, Jean-Edouard; Bechou, Laurent; Levrier, Bruno; Perona, Arnaud; Dollet, Alain
2014-09-01
This paper presents a preliminary study upon a novel approach proposed for highly accelerated ageing and reliability optimization of high concentrating photovoltaic (HCPV) cells and assemblies. The intended approach aims to overcome several limitations of some current accelerated ageing tests (AAT) adopted up today, proposing the use of an alternative experimental set-up for performing faster and more realistic thermal cycles, under real sun, without the involvement of environmental chamber. The study also includes specific characterization techniques, before and after each AAT sequence, which respectively provide the initial and final diagnosis on the condition of the tested sample. The acquired data from these diagnostic/characterization methods are then used as indices to determine both quantitatively and qualitatively the severity of degradation and, thus, the ageing level for each tested HCPV assembly or cell sample. Ultimate goal of such "initial diagnosis - AAT - final diagnosis" sequences is to provide the basis for a future work on the reliability analysis of the main degradation mechanisms and confident prediction of failure propagation in HCPV cells, by means of acceleration factor (AF) and mean-time-to-failure (MTTF) estimations.
Effects of consensus training on the reliability of auditory perceptual ratings of voice quality.
Iwarsson, Jenny; Reinholt Petersen, Niels
2012-05-01
This study investigates the effect of consensus training of listeners on intrarater and interrater reliability and agreement of perceptual voice analysis. The use of such training, including a reference voice sample, could be assumed to make the internal standards held in memory common and more robust, which is of great importance to reduce the variability of auditory perceptual ratings. A prospective design with testing before and after training. Thirteen students of audiologopedics served as listening subjects. The ratings were made using a multidimensional protocol with four-point equal-appearing interval scales. The stimuli consisted of text reading by authentic dysphonic patients. The consensus training for each perceptual voice parameter included (1) definition, (2) underlying physiology, (3) presentation of carefully selected sound examples representing the parameter in three different grades followed by group discussions of perceived characteristics, and (4) practical exercises including imitation to make use of the listeners' proprioception. Intrarater reliability and agreement showed a marked improvement for intermittent aphonia but not for vocal fry. Interrater reliability was high for most parameters before training with a slight increase after training. Interrater agreement showed marked increases for most voice quality parameters as a result of the training. The results support the recommendation of specific consensus training, including use of a reference voice sample material, to calibrate, equalize, and stabilize the internal standards held in memory by the listeners. Copyright © 2012 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Writing Across the Curriculum: Reliability Testing of a Standardized Rubric.
Minnich, Margo; Kirkpatrick, Amanda J; Goodman, Joely T; Whittaker, Ali; Stanton Chapple, Helen; Schoening, Anne M; Khanna, Maya M
2018-06-01
Rubrics positively affect student academic performance; however, accuracy and consistency of the rubric and its use is imperative. The researchers in this study developed a standardized rubric for use across an undergraduate nursing curriculum, then evaluated the interrater reliability and general usability of the tool. Faculty raters graded papers using the standardized rubric, submitted their independent scoring for interrater reliability analyses, then participated in a focus group discussion regarding rubric use experience. Quantitative analysis of the data showed a high interrater reliability (α = .998). Content analysis of transcription revealed several positive themes: Consistency, Emphasis on Writing Ability, and Ability to Use the Rubric as a Teaching Tool. Areas for improvement included use of value words and difficulty with point allocation. Investigators recommend effective faculty orientation for rubric use and future work in developing a rubric to assess reflective writing. [J Nurs Educ. 2018;57(6):366-370.]. Copyright 2018, SLACK Incorporated.
Yamato, Tie Parma; Maher, Chris; Koes, Bart; Moseley, Anne
2017-06-01
The Physiotherapy Evidence Database (PEDro) scale has been widely used to investigate methodological quality in physiotherapy randomized controlled trials; however, its validity has not been tested for pharmaceutical trials. The aim of this study was to investigate the validity and interrater reliability of the PEDro scale for pharmaceutical trials. The reliability was also examined for the Cochrane Back and Neck (CBN) Group risk of bias tool. This is a secondary analysis of data from a previous study. We considered randomized placebo controlled trials evaluating any pain medication for chronic spinal pain or osteoarthritis. Convergent validity was evaluated by correlating the PEDro score with the summary score of the CBN risk of bias tool. The construct validity was tested using a linear regression analysis to determine the degree to which the total PEDro score is associated with treatment effect sizes, journal impact factor, and the summary score for the CBN risk of bias tool. The interrater reliability was estimated using the Prevalence and Bias Adjusted Kappa coefficient and 95% confidence interval (CI) for the PEDro scale and CBN risk of bias tool. Fifty-three trials were included, with 91 treatment effect sizes included in the analyses. The correlation between PEDro scale and CBN risk of bias tool was 0.83 (95% CI 0.76-0.88) after adjusting for reliability, indicating strong convergence. The PEDro score was inversely associated with effect sizes, significantly associated with the summary score for the CBN risk of bias tool, and not associated with the journal impact factor. The interrater reliability for each item of the PEDro scale and CBN risk of bias tool was at least substantial for most items (>0.60). The intraclass correlation coefficient for the PEDro score was 0.80 (95% CI 0.68-0.88), and for the CBN, risk of bias tool was 0.81 (95% CI 0.69-0.88). There was evidence for the convergent and construct validity for the PEDro scale when used to evaluate methodological quality of pharmacological trials. Both risk of bias tools have acceptably high interrater reliability. Copyright © 2017 Elsevier Inc. All rights reserved.
Test-retest and between-site reliability in a multicenter fMRI study.
Friedman, Lee; Stern, Hal; Brown, Gregory G; Mathalon, Daniel H; Turner, Jessica; Glover, Gary H; Gollub, Randy L; Lauriello, John; Lim, Kelvin O; Cannon, Tyrone; Greve, Douglas N; Bockholt, Henry Jeremy; Belger, Aysenil; Mueller, Bryon; Doty, Michael J; He, Jianchun; Wells, William; Smyth, Padhraic; Pieper, Steve; Kim, Seyoung; Kubicki, Marek; Vangel, Mark; Potkin, Steven G
2008-08-01
In the present report, estimates of test-retest and between-site reliability of fMRI assessments were produced in the context of a multicenter fMRI reliability study (FBIRN Phase 1, www.nbirn.net). Five subjects were scanned on 10 MRI scanners on two occasions. The fMRI task was a simple block design sensorimotor task. The impulse response functions to the stimulation block were derived using an FIR-deconvolution analysis with FMRISTAT. Six functionally-derived ROIs covering the visual, auditory and motor cortices, created from a prior analysis, were used. Two dependent variables were compared: percent signal change and contrast-to-noise-ratio. Reliability was assessed with intraclass correlation coefficients derived from a variance components analysis. Test-retest reliability was high, but initially, between-site reliability was low, indicating a strong contribution from site and site-by-subject variance. However, a number of factors that can markedly improve between-site reliability were uncovered, including increasing the size of the ROIs, adjusting for smoothness differences, and inclusion of additional runs. By employing multiple steps, between-site reliability for 3T scanners was increased by 123%. Dropping one site at a time and assessing reliability can be a useful method of assessing the sensitivity of the results to particular sites. These findings should provide guidance toothers on the best practices for future multicenter studies.
Night-to-night arousal variability and interscorer reliability of arousal measurements.
Loredo, J S; Clausen, J L; Ancoli-Israel, S; Dimsdale, J E
1999-11-01
Measurement of arousals from sleep is clinically important, however, their definition is not well standardized, and little data exist on reliability. The purpose of this study is to determine factors that affect arousal scoring reliability and night-to-night arousal variability. The night-to-night arousal variability and interscorer reliability was assessed in 20 subjects with and without obstructive sleep apnea undergoing attended polysomnography during two consecutive nights. Five definitions of arousal were studied, assessing duration of electroencephalographic (EEG) frequency changes, increases in electromyographic (EMG) activity and leg movement, association with respiratory events, as well as the American Sleep Disorders Association (ASDA) definition of arousals. NA. NA. NA. Interscorer reliability varied with the definition of arousal and ranged from an Intraclass correlation (ICC) of 0.19 to 0.92. Arousals that included increases in EMG activity or leg movement had the greatest reliability, especially when associated with respiratory events (ICC 0.76 to 0.92). The ASDA arousal definition had high interscorer reliability (ICC 0.84). Reliability was lowest for arousals consisting of EEG changes lasting <3 seconds (ICC 0.19 to 0.37). The within subjects night-to-night arousal variability was low for all arousal definitions In a heterogeneous population, interscorer arousal reliability is enhanced by increases in EMG activity, leg movements, and respiratory events and decreased by short duration EEG arousals. The arousal index night-to-night variability was low for all definitions.
Behrangrad, Shabnam; Kordi Yoosefinejad, Amin
2018-03-01
The purpose of this study is to investigate the validity and reliability of the Persian version of the Multidimensional Assessment of Fatigue Scale (MAFS) in an Iranian population with multiple sclerosis. A self-reported survey on fatigue including the MAFS, Fatigue Impact Scale and demographic measures was completed by 130 patients with multiple sclerosis and 60 healthy persons sampled with a convenience method. Test-retest reliability and validity were evaluated 3 days apart. Construct validity of the MAFS was assessed with the Fatigue Impact Scale. The MAFS had high internal consistency (Cronbach's alpha >0.9) and 3-d test-retest reliability (intraclass correlation coefficient = 0.99). Correlation between the Fatigue Impact Scale and MAFS was high (r = 0.99). Correlation between MAFS scores and the Expanded Disability Status Scale was also strong (r = 0.85). Questionnaire items showed acceptable item-scale correlation (0.968-0.993). The Persian version of the MAFS appears to be a valid and reliable questionnaire. It is an appropriate short multidimensional instrument to assess fatigue in patients with multiple sclerosis in clinical practice and research. Implications for Rehabilitation The Persian version of Multidimensional Assessment of Fatigue is a valid and reliable instrument for the assessment and monitoring the fatigue in Persian-language patients with multiple sclerosis. It is very easy to administer and a time efficient scale in comparison to other instruments evaluating fatigue in patients with multiple sclerosis.
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.
2002-01-01
Brittle materials are being used, or considered, for a wide variety of high tech applications that operate in harsh environments, including static and rotating turbine parts. thermal protection systems, dental prosthetics, fuel cells, oxygen transport membranes, radomes, and MEMS. Designing components to sustain repeated load without fracturing while using the minimum amount of material requires the use of a probabilistic design methodology. The CARES/Life code provides a general-purpose analysis tool that predicts the probability of failure of a ceramic component as a function of its time in service. For this presentation an interview of the CARES/Life program will be provided. Emphasis will be placed on describing the latest enhancements to the code for reliability analysis with time varying loads and temperatures (fully transient reliability analysis). Also, early efforts in investigating the validity of using Weibull statistics, the basis of the CARES/Life program, to characterize the strength of MEMS structures will be described as as well as the version of CARES/Life for MEMS (CARES/MEMS) being prepared which incorporates single crystal and edge flaw reliability analysis capability. It is hoped this talk will open a dialog for potential collaboration in the area of MEMS testing and life prediction.
Validity and test-retest reliability of the six-spot step test in persons after stroke.
Arvidsson Lindvall, Mialinn; Anderzén-Carlsson, Agneta; Appelros, Peter; Forsberg, Anette
2018-06-06
After stroke, asymmetric weight distribution is common with decreased balance control in standing and walking. The six-spot step test (SSST) includes a 5-m walk during which one leg shoves wooden blocks out of circles marked on the floor, thus assessing the ability to take load on each leg. The aim of the present study was to investigate the convergent and discriminant validity and test-retest reliability of the SSST in persons with stroke. Eighty-one participants were included. A cross-sectional study was performed, in which the SSST was conducted twice, 3-7 days apart. Validity was investigated using measures of dynamic balance and walking. Reliability was assessed using intraclass correlation coefficient, standard error of the measurement (SEM), and smallest real difference (SRD). The convergent validity was strong to moderate, and the test-retest reliability was good. The SEM% was 14.7%, and the SRD% was 40.8% based on the mean of four walks shoving twice with the paretic and twice with the non-paretic leg. Values on random measurement error were high affecting the use of the SSST for follow-up evaluations but the SSST can be a complementary measure of gait and balance.
NASA Astrophysics Data System (ADS)
Taylor, John R.; Stolz, Christopher J.
1993-08-01
Laser system performance and reliability depends on the related performance and reliability of the optical components which define the cavity and transport subsystems. High-average-power and long transport lengths impose specific requirements on component performance. The complexity of the manufacturing process for optical components requires a high degree of process control and verification. Qualification has proven effective in ensuring confidence in the procurement process for these optical components. Issues related to component reliability have been studied and provide useful information to better understand the long term performance and reliability of the laser system.
NASA Astrophysics Data System (ADS)
Taylor, J. R.; Stolz, C. J.
1992-12-01
Laser system performance and reliability depends on the related performance and reliability of the optical components which define the cavity and transport subsystems. High-average-power and long transport lengths impose specific requirements on component performance. The complexity of the manufacturing process for optical components requires a high degree of process control and verification. Qualification has proven effective in ensuring confidence in the procurement process for these optical components. Issues related to component reliability have been studied and provide useful information to better understand the long term performance and reliability of the laser system.
Mantarova, Stefka G; Velcheva, Irena V; Georgieva, Spaska O; Stambolieva, Katerina I
2013-01-01
The last twenty years have witnessed a surge of interest in the autonomic symptoms in Parkinson's disease (PD) and the possibilities to diagnose and treat them. The specialized questionnaire assessing the autonomic symptoms in Parkinson's disease (SCOPA-AUT) has been validated and available in English, Dutch and Spanish. In this study we aim at evaluating the validity, reliability and applicability of the Bulgarian version of SCOPA-AUT (SCOPA-AUT-BG). The study included 55 patients with idiopathic PD (mean age 64.4 +/- 8.9 yrs), and 40 healthy controls (mean age 58.5 +/- 9.4 yrs). Clinical severity and disease stage were assessed by United Parkinson's disease rating scale (UPRDS) and Hoen and Yahr (H&Y). Thirty-two of the PD patients completed SCOPA-AUT-BG again after a 7-day interval. Questionnaire reliability was analyzed by determining the internal consistency, homogeneity, discriminatory and construct validity and test-retest reliability. Analyses showed good internal consistency of the summary evaluation of SCOPA-AUT-BG (coefficient alpha of Cronbach = 0.79), which indicates the high reliability of the questionnaire. The lowest Cronbach's alpha coefficient (0.53) was found for the subscale "cardiovascular functions". A dominant role belongs to the subscales for gastrointestinal and urinary functions (Cronbach's Alpha > 0.7), where a significantly high correlation of PD with the UPDRS scale was observed. We found high test-retest reliability based on the responses associated with dysfunction of the gastrointestinal, urinary, thermoregulatory and pupillary autonomic systems. The correlation of the results of SCOPA-AUT-BG with UPDRS is higher than that with H&Y, and the construct validity is high except for the cardiovascular and pupillomotor functions subscales. The results of this study show that SCOPA-AUT-BG is a valid and reliable specialized questionnaire to evaluate autonomic function in patients with Parkinson's disease. Using it allows for more detailed clinical evaluation of these patients and justifies the need to refer them to specialized examination of autonomic functions.
NASA Technical Reports Server (NTRS)
Harkney, R. D.
1980-01-01
Increased system requirements and functional integration with the aircraft have placed an increased demand on control system capability and reliability. To provide these at an affordable cost and weight and because of the rapid advances in electronic technology, hydromechanical systems are being phased out in favor of digital electronic systems. The transition is expected to be orderly from electronic trimming of hydromechanical controls to full authority digital electronic control. Future propulsion system controls will be highly reliable full authority digital electronic with selected component and circuit redundancy to provide the required safety and reliability. Redundancy may include a complete backup control of a different technology for single engine applications. The propulsion control will be required to communicate rapidly with the various flight and fire control avionics as part of an integrated control concept.
Helicobacter pylori therapy: a paradigm shift
Graham, David Y; Dore, Maria Pina
2016-01-01
SUMMARY Helicobacter pylori (H. Pylori) is a leading cause of gastroduodenal disease, including gastric cancer. H. pylori eradication therapies and their efficacy are summarized. A number of current treatment regimens will reliably yield >90% or 95% cure rates with susceptible strains. None has proven to be superior. We show how to predict the efficacy of a regimen in any population provided one knows the prevalence of antibiotic resistance. As with other infectious diseases, therapy should always be susceptibility-based. Susceptibility testing should be demanded. We provide recommendations for empiric therapies when the only option and describe how to distinguish studies providing misinformation from those providing reliable and interpretable data. When treated as an infectious disease, high H. pylori cure rates are relatively simple to reliably achieve. PMID:27077447
Cui, Jin; Jia, Zhenyu; Zhi, Xin; Li, Xiaoqun; Zhai, Xiao; Cao, Liehu; Weng, Weizong; Zhang, Jun; Wang, Lin; Chen, Xiao; Su, Jiacan
2017-01-05
The Achilles tendon Total Rupture Score (ATRS), which is originally developed in 2007 in Swedish, is the only patient-reported outcome measure (PROM) for specific outcome assessment of an Achilles tendon rupture.Purpose of this study is to translate and cross-culturally adapt Achilles tendon Total Rupture Score (ATRS) into simplified Chinese, and primarily evaluate the responsiveness, reliability and validity. International recognized guideline which was designed by Beaton was followed to make the translation of ATRS from English into simplified Chinese version (CH-ATRS). A prospective cohort study was carried out for the cross-cultural adaptation. There were 112 participants included into the study. Psychometric properties including floor and ceiling effects, Cronbach's alpha, intraclass correlation coefficient, effect size, standard response mean, and construct validity were tested. The mean scores of CH-ATRS are 57.42 ± 13.70. No sign of floor or ceiling effect was found of CH-ATRS. High level of internal consistency was supported by the value of Cronbach's alpha (0.893). ICC (0.979, 95%CI: 0.984-0.993) was high to indicate the high test-retest reliability. Great responsive ness was proved with the high absolute value of ES and SRM (0.84 and 8.98, respectively). The total CH-ATRS score had very good correlation with physical function and body pain subscales of SF-36 (r = -0.758 and r = -0.694, respectively, p < 0.001), while poor correlation with vitality and role physical subscales of SF-36 (r = -0.033 and r = -0.025, respectively, p ≥ 0.05), which supported construct validity of CH-ATRS. This Chinese version of Achilles tendon Total Rupture Score (CH-ATRS) can be used as a reliable and valid instrument for Achilles tendon rupture assessing in Chinese-speaking population. Level of evidence II.
The development and testing of a qualitative instrument designed to assess critical thinking
NASA Astrophysics Data System (ADS)
Clauson, Cynthia Louisa
This study examined a qualitative approach to assess critical thinking. An instrument was developed that incorporates an assessment process based on Dewey's (1933) concepts of self-reflection and critical thinking as problem solving. The study was designed to pilot test the critical thinking assessment process with writing samples collected from a heterogeneous group of students. The pilot test included two phases. Phase 1 was designed to determine the validity and inter-rater reliability of the instrument using two experts in critical thinking, problem solving, and literacy development. Validity of the instrument was addressed by requesting both experts to respond to ten questions in an interview. The inter-rater reliability was assessed by analyzing the consistency of the two experts' scorings of the 20 writing samples to each other, as well as to my scoring of the same 20 writing samples. Statistical analyses included the Spearman Rho and the Kuder-Richardson (Formula 20). Phase 2 was designed to determine the validity and reliability of the critical thinking assessment process with seven science teachers. Validity was addressed by requesting the teachers to respond to ten questions in a survey and interview. Inter-rater reliability was addressed by comparing the seven teachers' scoring of five writing samples with my scoring of the same five writing samples. Again, the Spearman Rho and the Kuder-Richardson (Formula 20) were used to determine the inter-rater reliability. The validity results suggest that the instrument is helpful as a guide for instruction and provides a systematic method to teach and assess critical thinking while problem solving with students in the classroom. The reliability results show the critical thinking assessment instrument to possess fairly high reliability when used by the experts, but weak reliability when used by classroom teachers. A major conclusion was drawn that teachers, as well as students, would need to receive instruction in critical thinking and in how to use the assessment process in order to gain more consistent interpretations of the six problem-solving steps. Specific changes needing to be made in the instrument to improve the quality are included.
NASA Technical Reports Server (NTRS)
1988-01-01
A user's workshop for CARE 3, a reliability assessment tool designed and developed especially for the evaluation of high reliability fault tolerant digital systems, was held at NASA Langley Research Center on October 6 to 7, 1987. The main purpose of the workshop was to assess the evolutionary status of CARE 3. The activities of the workshop are documented and papers are included by user's of CARE 3 and NASA. Features and limitations of CARE 3 and comparisons to other tools are presented. The conclusions to a workshop questionaire are also discussed.
Test-retest and interrater reliability of the functional lower extremity evaluation.
Haitz, Karyn; Shultz, Rebecca; Hodgins, Melissa; Matheson, Gordon O
2014-12-01
Repeated-measures clinical measurement reliability study. To establish the reliability and face validity of the Functional Lower Extremity Evaluation (FLEE). The FLEE is a 45-minute battery of 8 standardized functional performance tests that measures 3 components of lower extremity function: control, power, and endurance. The reliability and normative values for the FLEE in healthy athletes are unknown. A face validity survey for the FLEE was sent to sports medicine personnel to evaluate the level of importance and frequency of clinical usage of each test included in the FLEE. The FLEE was then administered and rated for 40 uninjured athletes. To assess test-retest reliability, each athlete was tested twice, 1 week apart, by the same rater. To assess interrater reliability, 3 raters scored each athlete during 1 of the testing sessions. Intraclass correlation coefficients were used to assess the test-retest and interrater reliability of each of the FLEE tests. In the face validity survey, the FLEE tests were rated as highly important by 58% to 71% of respondents but frequently used by only 26% to 45% of respondents. Interrater reliability intraclass correlation coefficients ranged from 0.83 to 1.00, and test-retest reliability ranged from 0.71 to 0.95. The FLEE tests are considered clinically important for assessing lower extremity function by sports medicine personnel but are underused. The FLEE also is a reliable assessment tool. Future studies are required to determine if use of the FLEE to make return-to-play decisions may reduce reinjury rates.
Gearbox Reliability Collaborative Phase 3 Gearbox 2 Test Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Link, H.; Keller, J.; Guo, Y.
2013-04-01
Gearboxes in wind turbines have not been achieving their expected design life even though they commonly meet or exceed the design criteria specified in current design standards. One of the basic premises of the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) is that the low gearbox reliability results from the absence of critical elements in the design process or insufficient design tools. Key goals of the GRC are to improve design approaches and analysis tools and to recommend practices and test methods resulting in improved design standards for wind turbine gearboxes that lower the cost of energy (COE)more » through improved reliability. The GRC uses a combined gearbox testing, modeling and analysis approach, along with a database of information from gearbox failures collected from overhauls and investigation of gearbox condition monitoring techniques to improve wind turbine operations and maintenance practices. Testing of Gearbox 2 (GB2) using the two-speed turbine controller that has been used in prior testing. This test series will investigate non-torque loads, high-speed shaft misalignment, and reproduction of field conditions in the dynamometer. This test series will also include vibration testing using an eddy-current brake on the gearbox's high speed shaft.« less
Validity and reliability of a new ankle dorsiflexion measurement device.
Gatt, Alfred; Chockalingam, Nachiappan
2013-08-01
The assessment of the maximum ankle dorsiflexion angle is an important clinical examination procedure. Evidence shows that the traditional goniometer is highly unreliable, and various designs of goniometers to measure the maximum ankle dorsiflexion angle rely on the application of a known force to obtain reliable results. Hence, an innovative ankle dorsiflexion measurement device was designed to make this measurement more reliable by holding the foot in a selected posture without the application of a known moment. To report on the comprehensive validity and reliability testing carried out on the new device. Following validity testing, four different trials to test reliability of the ankle dorsiflexion measurement device were performed. These trials included inter-rater and intra-rater testings with a controlled moment, intra-rater reliability testing with knees flexed and extended without a controlled moment, intra-rater testing with a patient population, and inter-rater reliability testing between four raters of varying experience without controlling moment. All raters were blinded. A series of trials to test intra-rater and inter-rater reliabilities. Intra-rater reliability intraclass correlation coefficient was 0.98 and inter-rater reliability intraclass correlation coefficient (2,1) was 0.953 with a controlled moment. With uncontrolled moment, very high reliability for intra-tester was also achieved (intraclass correlation coefficient = 0.94 with knees extended and intraclass correlation coefficient = 0.95 with knees flexed). For the trial investigating test-retest reliability with actual patients, intraclass correlation coefficient of 0.99 was obtained. In the trial investigating four different raters with uncontrolled moment, intraclass correlation coefficient of 0.91 was achieved. The new ankle dorsiflexion measurement device is a valid and reliable device for measuring ankle dorsiflexion in both healthy subjects and patients, with both controlled and uncontrolled moments, even by multiple raters of varying experience when the foot is dorsiflexed to its end of range of motion. An ankle dorsiflexion measuring device has been designed to increase the reliability of ankle dorsiflexion measurement and replace the traditional goniometer. While the majority of similar devices rely on application of a known moment to perform this measurement, it has been shown that this is not required with the new ankle dorsiflexion measurement device and, rather, foot posture should be taken into consideration as this affects the maximum ankle dorsiflexion angle.
NASA Technical Reports Server (NTRS)
Wintucky, Edwin G.
2002-01-01
A power-efficient, miniature, easily manufactured, reservoir-type barium-dispenser thermionic cathode has been developed that offers the significant advantages of simultaneous high electron-emission current density (>2 A/sq cm) and very long life (>100,000 hr of continuous operation) when compared with the commonly used impregnated-type barium-dispenser cathodes. Important applications of this cathode are a wide variety of microwave and millimeter-wave vacuum electronic devices, where high output power and reliability (long life) are essential. We also expect it to enable the practical development of higher purveyance electron guns for lower voltage and more reliable device operation. The low cathode heater power and reduced size and mass are expected to be particularly beneficial in traveling-wave-tube amplifiers (TWTA's) for space communications, where future NASA mission requirements include smaller onboard spacecraft systems, higher data transmission rates (high frequency and output power) and greater electrical efficiency.
Jorgensen, J E; Rathleff, C R; Rathleff, M S; Andreasen, J
2016-12-01
The Oslo Sports Trauma Research Centre Overuse Injury Questionnaire (OSTRC-O) and the Oslo Sports Trauma Research Centre questionnaire on Health Problems (The OSTRC-H) make it possible to monitor illness and injury at regular intervals capturing prevalence and incidence of acute injury, overuse injury, and illnesses. The aim of this study was to translate, culturally adapt, and establish the face validity of the OSTRC-O and the OSTRC-H into a Danish context (DK) through cognitive interviews and the assessment of test-retest reliability. The OSTRC-O.DK was distributed to 57 heterogenous respondents; response rate was 89%. The OSTRC-H was distributed to 58 heterogenous respondents; response rate was 86%. No major disagreements were observed between the original and translated versions of the questionnaires. The OSTRC-O had high internal consistency (Cronbach's alpha 0.80-0.93). The primary reliability analyses including all participants, showed reliability ICC: 0.62 (95% CI: 0.42-0.77. The secondary reliability analyses that only included subjects who did not change injury region from the test to the retest showed an ICC of 0.86 (95% CI: 0.77-0.92).The questionnaires were found to be valid, reliable, and acceptable for use in a Danish population. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Enhanced parent selection algorithms in mintroute protocol
NASA Astrophysics Data System (ADS)
Kim, Ki-Il
2012-11-01
A low-rate, short-range wireless radio communication on a small device often hampers high reliability in wireless sensor networks. However, more applications are increasingly demanding high reliability. To meet this requirement, various approaches have been proposed in each viewpoint of layers. Among those, MintRoute is a well-known network layer approach to develop a new metric based on link quality for path selection towards the sink. By choosing the link with the highest measured value, it has a higher possibility to transmit a packet over the link without error. However, there are still several issues to be mentioned during operations. In this paper, we propose how to improve the MintRoute protocol through revised algorithms. They include a parent selection considering distance and level from the sink node, and a fast recovery method against failures. Simulations and analysis are performed by in order to validate the suitability of reduced end-to-end delay and fast recovery for failures, thus to enhance the reliability of communication.
[Validation of the German version of the Singing Voice Handicap Index].
Lorenz, A; Kleber, B; Büttner, M; Fuchs, M; Mürbe, D; Richter, B; Sandel, M; Nawka, T
2013-08-01
The Singing Voice Handicap Index (SVHI) was developed in the United States for the self-assessment of patients with singing problems. It has been translated into German and its reliability and validity have been assessed. In total, 54 (35 female, 19 male) dysphonic singers and 130 (74 female, 56 male) non-dysphonic professional singers were included in the study. Reliability rested on high test-retest reliability (r = 0.960, p ≤ 0.001, Pearson correlation) and a Cronbach's α of 0.975. A principal component analysis using the Varimax method and the results of the screeplot suggest the SVHI scored as a single scale. Validity rested on a highly significant correlation between the severity of the self-rated voice impairment by the patient and the total SVHI score. Dysphonic singers have significantly higher SVHI scores than healthy singers. The SVHI is thus suited to implementation as a diagnostic tool in German-speaking countries.
The NASA computer science research program plan
NASA Technical Reports Server (NTRS)
1983-01-01
A taxonomy of computer science is included, one state of the art of each of the major computer science categories is summarized. A functional breakdown of NASA programs under Aeronautics R and D, space R and T, and institutional support is also included. These areas were assessed against the computer science categories. Concurrent processing, highly reliable computing, and information management are identified.
Texas nutrition environment assessment of retail food stores (TxNEA-S): development and evaluation.
Gloria, Christian T; Steinhardt, Mary A
2010-11-01
Current nutrition environment instruments are typically designed to measure a small number of healthy foods based on national trends. They lack the depth to accurately measure the unique dietary choices of subpopulations, such as Texas consumers whose food preferences are influenced by Hispanic/Latino culture. Thus the purposes of the present study were to: (i) develop a comprehensive observational tool to measure the availability of healthy foods from retail stores in Texas; and (ii) conduct a pilot test to examine the tool's reliability, as well as differences in the availability of healthy foods in stores between high- and low-income neighbourhoods. Grocery and convenience stores were assessed for availability of healthy foods. Reliability was calculated using percentage agreement, and differences in availability were examined using 2 (store type) × 2 (neighbourhood income) ANOVA. One high-income and one low-income neighbourhood in Austin, Texas. A sample of thirty-eight stores comprising twenty-five convenience stores and thirteen grocery stores. The low-income neighbourhood had 324 % more convenience stores and 56 % fewer grocery stores than the high-income neighbourhood. High inter-rater (mean = 0·95) and test-retest reliability (mean = 0·92) and a significant interaction (P = 0·028) between store type and neighbourhood income were found. The TxNEA-S tool includes 106 healthy food items, such as fruits, vegetables, dairy, proteins and grains. The tool is reliable and face validity is affirmed by the Texas Department of Health. Grocery stores have more healthy foods than convenience stores, and high-income grocery stores offer more healthy foods than low-income grocery stores.
Komro, Kelli A; Livingston, Melvin D; Kominsky, Terrence K; Livingston, Bethany J; Garrett, Brady A; Molina, Mildred Maldonado; Boyd, Misty L
2015-01-01
Objective: American Indians (AIs) suffer from significant alcohol-related health disparities, and increased risk begins early. This study examined the reliability and validity of measures to be used in a preventive intervention trial. Reliability and validity across racial/ethnic subgroups are crucial to evaluate intervention effectiveness and promote culturally appropriate evidence-based practice. Method: To assess reliability and validity, we used three baseline surveys of high school students participating in a preventive intervention trial within the jurisdictional service area of the Cherokee Nation in northeastern Oklahoma. The 15-minute alcohol risk survey included 16 multi-item scales and one composite score measuring key proximal, primary, and moderating variables. Forty-four percent of the students indicated that they were AI (of whom 82% were Cherokee), including 23% who reported being AI only (n = 435) and 18% both AI and White (n = 352). Forty-seven percent reported being White only (n = 901). Results: Scales were adequately reliable for the full sample and across race/ethnicity defined by AI, AI/White, and White subgroups. Among the full sample, all scales had acceptable internal consistency, with minor variation across race/ethnicity. All scales had extensive to exemplary test–retest reliability and showed minimal variation across race/ethnicity. The eight proximal and two primary outcome scales were each significantly associated with the frequency of alcohol use during the past month in both the cross-sectional and the longitudinal models, providing support for both criterion validity and predictive validity. For most scales, interpretation of the strength of association and statistical significance did not differ between the racial/ethnic subgroups. Conclusions: The results support the reliability and validity of scales of a brief questionnaire measuring risk and protective factors for alcohol use among AI adolescents, primarily members of the Cherokee Nation. PMID:25486402
Limitations of Reliability for Long-Endurance Human Spaceflight
NASA Technical Reports Server (NTRS)
Owens, Andrew C.; de Weck, Olivier L.
2016-01-01
Long-endurance human spaceflight - such as missions to Mars or its moons - will present a never-before-seen maintenance logistics challenge. Crews will be in space for longer and be farther way from Earth than ever before. Resupply and abort options will be heavily constrained, and will have timescales much longer than current and past experience. Spare parts and/or redundant systems will have to be included to reduce risk. However, the high cost of transportation means that this risk reduction must be achieved while also minimizing mass. The concept of increasing system and component reliability is commonly discussed as a means to reduce risk and mass by reducing the probability that components will fail during a mission. While increased reliability can reduce maintenance logistics mass requirements, the rate of mass reduction decreases over time. In addition, reliability growth requires increased test time and cost. This paper assesses trends in test time requirements, cost, and maintenance logistics mass savings as a function of increase in Mean Time Between Failures (MTBF) for some or all of the components in a system. In general, reliability growth results in superlinear growth in test time requirements, exponential growth in cost, and sublinear benefits (in terms of logistics mass saved). These trends indicate that it is unlikely that reliability growth alone will be a cost-effective approach to maintenance logistics mass reduction and risk mitigation for long-endurance missions. This paper discusses these trends as well as other options to reduce logistics mass such as direct reduction of part mass, commonality, or In-Space Manufacturing (ISM). Overall, it is likely that some combination of all available options - including reliability growth - will be required to reduce mass and mitigate risk for future deep space missions.
Size–strain separation in diffraction line profile analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scardi, P.; Ermrich, M.; Fitch, A.
Separation of size and strain effects on diffraction line profiles has been studied in a round robin involving laboratory instruments and synchrotron radiation beamlines operating with different radiation, optics, detectors and experimental configurations. The studied sample, an extensively ball milled iron alloy powder, provides an ideal test case, as domain size broadening and strain broadening are of comparable size. The high energy available at some synchrotron radiation beamlines provides the best conditions for an accurate analysis of the line profiles, as the size–strain separation clearly benefits from a large number of Bragg peaks in the pattern; high counts, reliable intensitymore » values in low-absorption conditions, smooth background and data collection at different temperatures also support the possibility to include diffuse scattering in the analysis, for the most reliable assessment of the line broadening effect. However, results of the round robin show that good quality information on domain size distribution and microstrain can also be obtained using standard laboratory equipment, even when patterns include relatively few Bragg peaks, provided that the data are of good quality in terms of high counts and low and smooth background.« less
Van Spall, Harriette; Kassam, Alisha; Tollefson, Travis T
2015-08-01
Near-miss investigations in high reliability organizations (HROs) aim to mitigate risk and improve system safety. Healthcare settings have a higher rate of near-misses and subsequent adverse events than most high-risk industries, but near-misses are not systematically reported or analyzed. In this review, we will describe the strategies for near-miss analysis that have facilitated a culture of safety and continuous quality improvement in HROs. Near-miss analysis is routine and systematic in HROs such as aviation. Strategies implemented in aviation include the Commercial Aviation Safety Team, which undertakes systematic analyses of near-misses, so that findings can be incorporated into Standard Operating Procedures (SOPs). Other strategies resulting from incident analyses include Crew Resource Management (CRM) for enhanced communication, situational awareness training, adoption of checklists during operations, and built-in redundancy within systems. Health care organizations should consider near-misses as opportunities for quality improvement. The systematic reporting and analysis of near-misses, commonplace in HROs, can be adapted to health care settings to prevent adverse events and improve clinical outcomes.
Size–strain separation in diffraction line profile analysis
Scardi, P.; Ermrich, M.; Fitch, A.; ...
2018-05-29
Separation of size and strain effects on diffraction line profiles has been studied in a round robin involving laboratory instruments and synchrotron radiation beamlines operating with different radiation, optics, detectors and experimental configurations. The studied sample, an extensively ball milled iron alloy powder, provides an ideal test case, as domain size broadening and strain broadening are of comparable size. The high energy available at some synchrotron radiation beamlines provides the best conditions for an accurate analysis of the line profiles, as the size–strain separation clearly benefits from a large number of Bragg peaks in the pattern; high counts, reliable intensitymore » values in low-absorption conditions, smooth background and data collection at different temperatures also support the possibility to include diffuse scattering in the analysis, for the most reliable assessment of the line broadening effect. However, results of the round robin show that good quality information on domain size distribution and microstrain can also be obtained using standard laboratory equipment, even when patterns include relatively few Bragg peaks, provided that the data are of good quality in terms of high counts and low and smooth background.« less
A sensitive and reliable test instrument to assess swimming in rats with spinal cord injury.
Xu, Ning; Åkesson, Elisabet; Holmberg, Lena; Sundström, Erik
2015-09-15
For clinical translation of experimental spinal cord injury (SCI) research, evaluation of animal SCI models should include several sensorimotor functions. Validated and reliable assessment tools should be applicable to a wide range of injury severity. The BBB scale is the most widely used test instrument, but similar to most others it is used to assess open field ambulation. We have developed an assessment tool for swimming in rats with SCI, with high discriminative power and sensitivity to functional recovery after mild and severe injuries, without need for advanced test equipment. We studied various parameters of swimming in four groups of rats with thoracic SCI of different severity and a control group, for 8 weeks after surgery. Six parameters were combined in a multiple item scale, the Karolinska Institutet Swim Assessment Tool (KSAT). KSAT scores for all SCI groups showed consistent functional improvement after injury, and significant differences between the five experimental groups. The internal consistency, the inter-rater and the test-retest reliability were very high. The KSAT score was highly correlated to the cross-section area of white matter spared at the injury epicenter. Importantly, even after 8 weeks of recovery the KSAT score reliably discriminated normal animals from those inflicted by the mildest injury, and also displayed the recovery of the most severely injured rats. We conclude that this swim scale is an efficient and reliable tool to assess motor activity during swimming, and an important addition to the methods available for evaluating rat models of SCI. Copyright © 2015 Elsevier B.V. All rights reserved.
Hulteen, Ryan M; Barnett, Lisa M; Morgan, Philip J; Robinson, Leah E; Barton, Christian J; Wrotniak, Brian H; Lubans, David R
2018-03-28
Numerous skill batteries assess fundamental motor skill (e.g., kick, hop) competence. Few skill batteries examine lifelong physical activity skill competence (e.g., resistance training). This study aimed to develop and assess the content validity, test-retest and inter-rater reliability of the "Lifelong Physical Activity Skills Battery". Development of the skill battery occurred in three stages: i) systematic reviews of lifelong physical activity participation rates and existing motor skill assessment tools, ii) practitioner consultation and iii) research expert consultation. The final battery included eight skills: grapevine, golf swing, jog, push-up, squat, tennis forehand, upward dog and warrior I. Adolescents (28 boys, 29 girls; M = 15.8 years, SD = 0.4 years) completed the Lifelong Physical Activity Skills Battery on two occasions two weeks apart. The skill battery was highly reliable (ICC = 0.84, 95% CI = 0.72-0.90) with individual skill reliability scores ranging from moderate (warrior I; ICC = 0.56) to high (tennis forehand; ICC = 0.82). Typical error (4.0; 95% CI 3.4-5.0) and proportional bias (r = -0.21, p = .323) were low. This study has provided preliminary evidence for the content validity and reliability of the Lifelong Physical Activity Skills Battery in an adolescent population.
de Albuquerque, Priscila Maria Nascimento Martins; de Alencar, Geisa Guimarães; de Oliveira, Daniela Araújo; de Siqueira, Gisela Rocha
2018-01-01
The aim of this study was to examine and interpret the concordance, accuracy, and reliability of photogrammetric protocols available in the literature for evaluating cervical lordosis in an adult population aged 18 to 59 years. A systematic search of 6 electronic databases (MEDLINE via PubMed, LILACS, CINAHL, Scopus, ScienceDirect, and Web of Science) located studies that assessed the reliability and/or concordance and/or accuracy of photogrammetric protocols for evaluating cervical lordosis, compared with radiography. Articles published through April 2016 were selected. Two independent reviewers used a critical appraisal tool (QUADAS and QAREL) to assess the quality of the selected studies. Two studies were included in the review and had high levels of reliability (intraclass correlation coefficient: 0.974-0.98). Only 1 study assessed the concordance between the methods, which was calculated using Pearson's correlation coefficient. To date, the accuracy of photogrammetry has not been investigated thoroughly. We encountered no study in the literature that investigated the accuracy of photogrammetry in diagnosing hyperlordosis of cervical spine. However, both current studies report high levels of intra- and interrater reliability. To increase the level of evidence of photogrammetry in the evaluation of cervical lordosis, it is necessary to conduct further studies using a larger sample to increase the external validity of the findings. Copyright © 2018. Published by Elsevier Inc.
Unreliability as a Threat to Understanding Psychopathology: The Cautionary Tale of Attentional Bias
Rodebaugh, Thomas L.; Scullin, Rachel B.; Langer, Julia K.; Dixon, David J.; Huppert, Jonathan D.; Bernstein, Amit; Zvielli, Ariel; Lenze, Eric J.
2016-01-01
The use of unreliable measures constitutes a threat to our understanding of psychopathology, because advancement of science using both behavioral and biologically-oriented measures can only be certain if such measurements are reliable. Two pillars of NIMH’s portfolio – the Research Domain Criteria (RDoC) initiative for psychopathology and the target engagement initiative in clinical trials – cannot succeed without measures that possess the high reliability necessary for tests involving mediation and selection based on individual differences. We focus on the historical lack of reliability of attentional bias measures as an illustration of how reliability can pose a threat to our understanding. Our own data replicate previous findings of poor reliability for traditionally-used scores, which suggests a serious problem with the ability to test theories regarding attentional bias. This lack of reliability may also suggest problems with the assumption (in both theory and the formula for the scores) that attentional bias is consistent and stable across time. In contrast, measures accounting for attention as a dynamic process in time show good reliability in our data. The field is sorely in need of research reporting findings and reliability for attentional bias scores using multiple methods, including those focusing on dynamic processes over time. We urge researchers to test and report reliability of all measures, considering findings of low reliability not just as a nuisance but as an opportunity to modify and improve upon the underlying theory. Full assessment of reliability of measures will maximize the possibility that RDoC (and psychological science more generally) will succeed. PMID:27322741
NASA Technical Reports Server (NTRS)
Kandil, O. A.
1981-01-01
Progress is reported in the development of reliable nonlinear vortex methods for predicting the steady and unsteady aerodynamic loads of highly sweptback wings at large angles of attack. Abstracts of the papers, talks, and theses produced through this research are included. The modified nonlinear discrete vortex method and the nonlinear hybrid vortex method are highlighted.
ERIC Educational Resources Information Center
Ekici, Erhan
2016-01-01
The aim of this study is to develop a valid and reliable instrument to assess why physics courses are perceived as one of the most difficult courses among high school students and to investigate the reasons why students have difficulty in learning physics through this scale. This study includes the development and validation studies of the…
High-Reliability Health Care: Getting There from Here
Chassin, Mark R; Loeb, Jerod M
2013-01-01
Context Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer “project fatigue” because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. Methods We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals’ readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. Findings We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Conclusions Hospitals can make substantial progress toward high reliability by undertaking several specific organizational change initiatives. Further research and practical experience will be necessary to determine the validity and effectiveness of this framework for high-reliability health care. PMID:24028696
High-reliability health care: getting there from here.
Chassin, Mark R; Loeb, Jerod M
2013-09-01
Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer "project fatigue" because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals' readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Hospitals can make substantial progress toward high reliability by undertaking several specific organizational change initiatives. Further research and practical experience will be necessary to determine the validity and effectiveness of this framework for high-reliability health care. © 2013 The Authors. The Milbank Quarterly published by Wiley Periodicals Inc. on behalf of Milbank Memorial Fund.
Effect of Random Thermal Spikes on Stirling Convertor Heater Head Reliability
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Korovaichuk, Igor; Halford, Gary R.
2004-01-01
Onboard radioisotope power systems being developed to support future NASA exploration missions require reliable design lifetimes of up to 14 yr and beyond. The structurally critical heater head of the high-efficiency developmental Stirling power convertor has undergone extensive computational analysis of operating temperatures (up to 650 C), stresses, and creep resistance of the thin-walled Inconel 718 bill of material. Additionally, assessment of the effect of uncertainties in the creep behavior of the thin-walled heater head, the variation in the manufactured thickness, variation in control temperature, and variation in pressure on the durability and reliability were performed. However, it is possible for the heater head to experience rare incidences of random temperature spikes (excursions) of short duration. These incidences could occur randomly with random magnitude and duration during the desired mission life. These rare incidences could affect the creep strain rate and therefore the life. The paper accounts for these uncertainties and includes the effect of such rare incidences, random in nature, on the reliability. The sensitivities of variables affecting the reliability are quantified and guidelines developed to improve the reliability are outlined. Furthermore, the quantified reliability is being verified with test data from the accelerated benchmark tests being conducted at the NASA Glenn Research Center.
Reliability-Based Life Assessment of Stirling Convertor Heater Head
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Halford, Gary R.; Korovaichuk, Igor
2004-01-01
Onboard radioisotope power systems being developed and planned for NASA's deep-space missions require reliable design lifetimes of up to 14 yr. The structurally critical heater head of the high-efficiency Stirling power convertor has undergone extensive computational analysis of operating temperatures, stresses, and creep resistance of the thin-walled Inconel 718 bill of material. A preliminary assessment of the effect of uncertainties in the material behavior was also performed. Creep failure resistance of the thin-walled heater head could show variation due to small deviations in the manufactured thickness and in uncertainties in operating temperature and pressure. Durability prediction and reliability of the heater head are affected by these deviations from nominal design conditions. Therefore, it is important to include the effects of these uncertainties in predicting the probability of survival of the heater head under mission loads. Furthermore, it may be possible for the heater head to experience rare incidences of small temperature excursions of short duration. These rare incidences would affect the creep strain rate and, therefore, the life. This paper addresses the effects of such rare incidences on the reliability. In addition, the sensitivities of variables affecting the reliability are quantified, and guidelines developed to improve the reliability are outlined. Heater head reliability is being quantified with data from NASA Glenn Research Center's accelerated benchmark testing program.
NASA Astrophysics Data System (ADS)
Yu, Zheng
2002-08-01
Facing the new demands of the optical fiber communications market, almost all the performance and reliability of optical network system are dependent on the qualification of the fiber optics components. So, how to comply with the system requirements, the Telcordia / Bellcore reliability and high-power testing has become the key issue for the fiber optics components manufacturers. The qualification of Telcordia / Bellcore reliability or high-power testing is a crucial issue for the manufacturers. It is relating to who is the outstanding one in the intense competition market. These testing also need maintenances and optimizations. Now, work on the reliability and high-power testing have become the new demands in the market. The way is needed to get the 'Triple-Win' goal expected by the component-makers, the reliability-testers and the system-users. To those who are meeting practical problems for the testing, there are following seven topics that deal with how to shoot the common mistakes to perform qualify reliability and high-power testing: ¸ Qualification maintenance requirements for the reliability testing ¸ Lots control for preparing the reliability testing ¸ Sampling select per the reliability testing ¸ Interim measurements during the reliability testing ¸ Basic referencing factors relating to the high-power testing ¸ Necessity of re-qualification testing for the changing of producing ¸ Understanding the similarity for product family by the definitions
Reliability of Semi-Automated Segmentations in Glioblastoma.
Huber, T; Alber, G; Bette, S; Boeckh-Behrens, T; Gempt, J; Ringel, F; Alberts, E; Zimmer, C; Bauer, J S
2017-06-01
In glioblastoma, quantitative volumetric measurements of contrast-enhancing or fluid-attenuated inversion recovery (FLAIR) hyperintense tumor compartments are needed for an objective assessment of therapy response. The aim of this study was to evaluate the reliability of a semi-automated, region-growing segmentation tool for determining tumor volume in patients with glioblastoma among different users of the software. A total of 320 segmentations of tumor-associated FLAIR changes and contrast-enhancing tumor tissue were performed by different raters (neuroradiologists, medical students, and volunteers). All patients underwent high-resolution magnetic resonance imaging including a 3D-FLAIR and a 3D-MPRage sequence. Segmentations were done using a semi-automated, region-growing segmentation tool. Intra- and inter-rater-reliability were addressed by intra-class-correlation (ICC). Root-mean-square error (RMSE) was used to determine the precision error. Dice score was calculated to measure the overlap between segmentations. Semi-automated segmentation showed a high ICC (> 0.985) for all groups indicating an excellent intra- and inter-rater-reliability. Significant smaller precision errors and higher Dice scores were observed for FLAIR segmentations compared with segmentations of contrast-enhancement. Single rater segmentations showed the lowest RMSE for FLAIR of 3.3 % (MPRage: 8.2 %). Both, single raters and neuroradiologists had the lowest precision error for longitudinal evaluation of FLAIR changes. Semi-automated volumetry of glioblastoma was reliably performed by all groups of raters, even without neuroradiologic expertise. Interestingly, segmentations of tumor-associated FLAIR changes were more reliable than segmentations of contrast enhancement. In longitudinal evaluations, an experienced rater can detect progressive FLAIR changes of less than 15 % reliably in a quantitative way which could help to detect progressive disease earlier.
Kahraman, Turhan; Özdoğar, Asiye Tuba; Honan, Cynthia Alison; Ertekin, Özge; Özakbaş, Serkan
2018-05-09
To linguistically and culturally adapt the Multiple Sclerosis Work Difficulties Questionnaire-23 (MSWDQ-23) for use in Turkey, and to examine its reliability and validity. Following standard forward-back translation of the MSWDQ-23, it was administered to 124 people with multiple sclerosis (MS). Validity was evaluated using related outcome measures including those related to employment status and expectations, disability level, fatigue, walking, and quality of life. Randomly selected participants were asked to complete the MSWDQ-23 again to assess test-retest reliability. Confirmatory factor analysis on the MSWDQ-23 demonstrated a good fit for the data, and the internal consistency of each subscale was excellent. The test-retest reliability for the total score, psychological/cognitive barriers, physical barriers, and external barriers subscales were high. The MSWDQ-23 and its subscales were positively correlated with the employment, disability level, walking, and fatigue outcome measures. This study suggests that the Turkish version of MSWDQ-23 has high reliability and adequate validity, and it can be used to determine the difficulties faced by people with multiple sclerosis in workplace. Moreover, the study provides evidence about the test-retest reliability of the questionnaire. Implications for rehabilitation Multiple sclerosis affects young people of working age. Understanding work-related problems is crucial to enhance people with multiple sclerosis likelihood of maintaining their job. The Multiple Sclerosis Work Difficulties Questionnaire-23 (MSWDQ-23) is a valid and reliable measure of perceived workplace difficulties in people with multiple sclerosis: we presented its validation to Turkish. Professionals working in the field of vocational rehabilitation may benefit from using the MSWDQ-23 to predict the current work outcomes and future employment expectations.
Automated inspection of solder joints for surface mount technology
NASA Technical Reports Server (NTRS)
Savage, Robert M.; Park, Hyun Soo; Fan, Mark S.
1993-01-01
Researchers at NASA/GSFC evaluated various automated inspection systems (AIS) technologies using test boards with known defects in surface mount solder joints. These boards were complex and included almost every type of surface mount device typical of critical assemblies used for space flight applications: X-ray radiography; X-ray laminography; Ultrasonic Imaging; Optical Imaging; Laser Imaging; and Infrared Inspection. Vendors, representative of the different technologies, inspected the test boards with their particular machine. The results of the evaluation showed limitations of AIS. Furthermore, none of the AIS technologies evaluated proved to meet all of the inspection criteria for use in high-reliability applications. It was found that certain inspection systems could supplement but not replace manual inspection for low-volume, high-reliability, surface mount solder joints.
Ahlström, Isabell; Hellström, Karin; Emtner, Margareta; Anens, Elisabeth
2015-03-01
To examine the test-retest reliability of the Swedish translated version of the Exercise Self-Efficacy Scale (S-ESES) in people with neurological disease and to examine internal consistency. Test-retest study. A total of 30 adults with neurological diseases including: Parkinson's disease; Multiple Sclerosis; Cervical Dystonia; and Charcot-Marie-Tooth disease. The S-ESES was sent twice by surface mail. Completion interval mean was 16 days apart. Weighted kappa, intraclass correlation coefficient 2,1 [ICC (2,1)], standard error of measurement (SEM), also expressed as a percentage value (SEM%), and Cronbach's alpha were calculated. The relative reliability of the test-retest results showed substantial agreement measured using weighted kappa (MD = 0.62) and a very high-reliability ICC (2,1) (0.92). Absolute reliability measured using SEM was 5.3 and SEM% was 20.7. Excellent internal consistency was shown, with an alpha coefficient of 0.91 (test 1) and 0.93 (test 2). The S-ESES is recommended for use in research and in clinical work for people with neurological diseases. The low-absolute reliability, however, indicates a limited ability to measure changes on an individual level.
2016-03-01
A BOUNCE? A STUDY ON RESILIENCE AND HUMAN RELATIONS IN A HIGH RELIABILITY ORGANIZATION by Robert D. Johns March 2016 Thesis Advisor...RELATIONS IN A HIGH RELIABILITY ORGANIZATION 5. FUNDING NUMBERS 6. AUTHOR(S) Robert D. Johns 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES...200 words) This study analyzes the various resilience factors associated with a military high reliability organization (HRO). The data measuring
The Effect of Incorrect Reliability Information on Expectations, Perceptions, and Use of Automation.
Barg-Walkow, Laura H; Rogers, Wendy A
2016-03-01
We examined how providing artificially high or low statements about automation reliability affected expectations, perceptions, and use of automation over time. One common method of introducing automation is providing explicit statements about the automation's capabilities. Research is needed to understand how expectations from such introductions affect perceptions and use of automation. Explicit-statement introductions were manipulated to set higher-than (90%), same-as (75%), or lower-than (60%) levels of expectations in a dual-task scenario with 75% reliable automation. Two experiments were conducted to assess expectations, perceptions, compliance, reliance, and task performance over (a) 2 days and (b) 4 days. The baseline assessments showed initial expectations of automation reliability matched introduced levels of expectation. For the duration of each experiment, the lower-than groups' perceptions were lower than the actual automation reliability. However, the higher-than groups' perceptions were no different from actual automation reliability after Day 1 in either study. There were few differences between groups for automation use, which generally stayed the same or increased with experience using the system. Introductory statements describing artificially low automation reliability have a long-lasting impact on perceptions about automation performance. Statements including incorrect automation reliability do not appear to affect use of automation. Introductions should be designed according to desired outcomes for expectations, perceptions, and use of the automation. Low expectations have long-lasting effects. © 2015, Human Factors and Ergonomics Society.
Varsani, Hemlata; Charman, Susan C; Li, Charles K; Marie, Suely K N; Amato, Anthony A; Banwell, Brenda; Bove, Kevin E; Corse, Andrea M; Emslie-Smith, Alison M; Jacques, Thomas S; Lundberg, Ingrid E; Minetti, Carlo; Nennesmo, Inger; Rushing, Elisabeth J; Sallum, Adriana M E; Sewry, Caroline; Pilkington, Clarissa A; Holton, Janice L; Wedderburn, Lucy R
2015-01-01
Objectives To study muscle biopsy tissue from patients with juvenile dermatomyositis (JDM) in order to test the reliability of a score tool designed to quantify the severity of histological abnormalities when applied to biceps humeri in addition to quadriceps femoris. Additionally, to evaluate whether elements of the tool correlate with clinical measures of disease severity. Methods 55 patients with JDM with muscle biopsy tissue and clinical data available were included. Biopsy samples (33 quadriceps, 22 biceps) were prepared and stained using standardised protocols. A Latin square design was used by the International Juvenile Dermatomyositis Biopsy Consensus Group to score cases using our previously published score tool. Reliability was assessed by intraclass correlation coefficient (ICC) and scorer agreement (α) by assessing variation in scorers’ ratings. Scores from the most reliable tool items correlated with clinical measures of disease activity at the time of biopsy. Results Inter- and intraobserver agreement was good or high for many tool items, including overall assessment of severity using a Visual Analogue Scale. The tool functioned equally well on biceps and quadriceps samples. A modified tool using the most reliable score items showed good correlation with measures of disease activity. Conclusions The JDM biopsy score tool has high inter- and intraobserver agreement and can be used on both biceps and quadriceps muscle tissue. Importantly, the modified tool correlates well with clinical measures of disease activity. We propose that standardised assessment of muscle biopsy tissue should be considered in diagnostic investigation and clinical trials in JDM. PMID:24064003
[Balanced scorecard for performance measurement of a nursing organization in a Korean hospital].
Hong, Yoonmi; Hwang, Kyung Ja; Kim, Mi Ja; Park, Chang Gi
2008-02-01
The purpose of this study was to develop a balanced scorecard (BSC) for performance measurement of a Korean hospital nursing organization and to evaluate the validity and reliability of performance measurement indicators. Two hundred fifty-nine nurses in a Korean hospital participated in a survey questionnaire that included 29-item performance evaluation indicators developed by investigators of this study based on the Kaplan and Norton's BSC (1992). Cronbach's alpha was used to test the reliability of the BSC. Exploratory and confirmatory factor analysis with a structure equation model (SEM) was applied to assess the construct validity of the BSC. Cronbach's alpha of 29 items was .948. Factor analysis of the BSC showed 5 principal components (eigen value >1.0) which explained 62.7% of the total variance, and it included a new one, community service. The SEM analysis results showed that 5 components were significant for the hospital BSC tool. High degree of reliability and validity of this BSC suggests that it may be used for performance measurements of a Korean hospital nursing organization. Future studies may consider including a balanced number of nurse managers and staff nurses in the study. Further data analysis on the relationships among factors is recommended.
Peer-review for selection of oral presentations for conferences: Are we reliable?
Deveugele, Myriam; Silverman, Jonathan
2017-11-01
Although peer-review for journal submission, grant-applications and conference submissions has been called 'a counter- stone of science', and even 'the gold standard for evaluating scientific merit', publications on this topic remain scares. Research that has investigated peer-review reveals several issues and criticisms concerning bias, poor quality review, unreliability and inefficiency. The most important weakness of the peer review process is the inconsistency between reviewers leading to inadequate inter-rater reliability. To report the reliability of ratings for a large international conference and to suggest possible solutions to overcome the problem. In 2016 during the International Conference on Communication in Healthcare, organized by EACH: International Association for Communication in Healthcare, a calibration exercise was proposed and feedback was reported back to the participants of the exercise. Most abstracts, as well as most peer-reviewers, receive and give scores around the median. Contrary to the general assumption that there are high and low scorers, in this group only 3 peer-reviewers could be identified with a high mean, while 7 has a low mean score. Only 2 reviewers gave only high ratings (4 and 5). Of the eight abstracts included in this exercise, only one abstract received a high mean score and one a low mean score. Nevertheless, both these abstracts received both low and high scores; all other abstracts received all possible scores. Peer-review of submissions for conferences are, in accordance with the literature, unreliable. New and creative methods will be needed to give the participants of a conference what they really deserve: a more reliable selection of the best abstracts. More raters per abstract improves the inter-rater reliability; training of reviewers could be helpful; providing feedback to reviewers can lead to less inter-rater disagreement; fostering negative peer-review (rejecting the inappropriate submissions) rather than a positive (accepting the best) could be fruitful for selecting abstracts for conferences. Copyright © 2017 Elsevier B.V. All rights reserved.
Validity of a smartphone protractor to measure sagittal parameters in adult spinal deformity.
Kunkle, William Aaron; Madden, Michael; Potts, Shannon; Fogelson, Jeremy; Hershman, Stuart
2017-10-01
Smartphones have become an integral tool in the daily life of health-care professionals (Franko 2011). Their ease of use and wide availability often make smartphones the first tool surgeons use to perform measurements. This technique has been validated for certain orthopedic pathologies (Shaw 2012; Quek 2014; Milanese 2014; Milani 2014), but never to assess sagittal parameters in adult spinal deformity (ASD). This study was designed to assess the validity, reproducibility, precision, and efficiency of using a smartphone protractor application to measure sagittal parameters commonly measured in ASD assessment and surgical planning. This study aimed to (1) determine the validity of smartphone protractor applications, (2) determine the intra- and interobserver reliability of smartphone protractor applications when used to measure sagittal parameters in ASD, (3) determine the efficiency of using a smartphone protractor application to measure sagittal parameters, and (4) elucidate whether a physician's level of experience impacts the reliability or validity of using a smartphone protractor application to measure sagittal parameters in ASD. An experimental validation study was carried out. Thirty standard 36″ standing lateral radiographs were examined. Three separate measurements were performed using a marker and protractor; then at a separate time point, three separate measurements were performed using a smartphone protractor application for all 30 radiographs. The first 10 radiographs were then re-measured two more times, for a total of three measurements from both the smartphone protractor and marker and protractor. The parameters included lumbar lordosis, pelvic incidence, and pelvic tilt. Three raters performed all measurements-a junior level orthopedic resident, a senior level orthopedic resident, and a fellowship-trained spinal deformity surgeon. All data, including the time to perform the measurements, were recorded, and statistical analysis was performed to determine intra- and interobserver reliability, as well as accuracy, efficiency, and precision. Statistical analysis using the intra- and interclass correlation coefficient was calculated using R (version 3.3.2, 2016) to determine the degree of intra- and interobserver reliability. High rates of intra- and interobserver reliability were observed between the junior resident, senior resident, and attending surgeon when using the smartphone protractor application as demonstrated by high inter- and intra-class correlation coefficients greater than 0.909 and 0.874 respectively. High rates of inter- and intraobserver reliability were also seen between the junior resident, senior resident, and attending surgeon when a marker and protractor were used as demonstrated by high inter- and intra-class correlation coefficients greater than 0.909 and 0.807 respectively. The lumbar lordosis, pelvic incidence, and pelvic tilt values were accurately measured by all three raters, with excellent inter- and intra-class correlation coefficient values. When the first 10 radiographs were re-measured at different time points, a high degree of precision was noted. Measurements performed using the smartphone application were consistently faster than using a marker and protractor-this difference reached statistical significance of p<.05. Adult spinal deformity radiographic parameters can be measured accurately, precisely, reliably, and more efficiently using a smartphone protractor application than with a standard protractor and wax pencil. A high degree of intra- and interobserver reliability was seen between the residents and attending surgeon, indicating measurements made with a smartphone protractor are unaffected by an observer's level of experience. As a result, smartphone protractors may be used when planning ASD surgery. Copyright © 2017 Elsevier Inc. All rights reserved.
The Reliability of Anthropometric Measurements Used Preoperatively in Aesthetic Breast Surgery.
Isaac, Kathryn V; Murphy, Blake D; Beber, Brett; Brown, Mitchell
2016-04-01
Patient outcomes in aesthetic breast surgery are highly dependent on breast measurements used in preoperative planning. The purpose of this study is to determine the reliability of anthropometric breast measurements. Four raters measured 28 women using 7 measurements: sternal notch to nipple distance (Sn-N), nipple to midline (N-M), nipple to inframammary-fold distance under maximal stretch (N-IMF), breast base width (BW), soft tissue pinch thickness of the upper pole (STPT:UP), STPT at the inframammary fold (STPT:IMF), and anterior pull skin stretch (APSS). Reliability was assessed using intra-class correlation coefficients (ICCs). Inter-rater reliability was excellent for Sn-N, N-M, and BW (ICC = 0.94, 0.90, and 0.76, respectively) and was good for N-IMF (ICC = 0.70). The STPT:UP, STPT:IMF, and APSS measurements were not reliable between raters (ICC < 0.2). Intra-rater reliability was excellent for Sn-N, N-M, and BW for all raters (all ICC > 0.75). The N-IMF intra-rater reliability was excellent in senior raters (ICC > 0.75) and good in junior raters (ICC > 0.6). The STPT:UP, STPT:IMF, and APSS measurements showed fair or poor reliability for most raters (ICC < 0.6). The Sn-N, N-M, and BW measurements are very reliable. Dynamic measurements including APSS, STPT:UP, and STUP:IMF are unreliable. N-IMF is the only reliable dynamic measurement, and its reliability improves with increasing clinical experience. The variable reliability of preoperative measurements must be considered in the planning of aesthetic breast surgery. 4 Diagnostic. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.
Aminoff, Bechor Z; Purits, Elena; Noy, Shlomo; Adunsky, Abraham
2004-01-01
Assessment of suffering is extremely important in dying end-stage dementia patients (ESDP). We have developed and examined the reliability and validity of the Mini-Suffering State Examination (MSSE), in 103 consecutive bedridden ESDP. Main outcome measures included inter-observer reliability and concurrent validity. Reliability of the MSSE questionnaire was satisfactory, with Cronbach alpha values of 0.735 and 0.718 for the two physicians (Ph-1, Ph-2), respectively. The kappa agreement coefficient was 0.791. There was a high agreement for seven items (kappa 0.882-0.972) and a substantial agreement for the other three items (kappa 0.621-0.682) of the MSSE. MSSE was validated versus the comfort assessment in dying with dementia (CAD-EOLD) scale and resulted in a significant Pearson correlation (r=-0.796, P<0.001). We conclude that the MSSE scale is a reliable and valid clinical tool, recommended for evaluating the severity of the patient's condition and the level of suffering of ESDP. Use of MSSE may improve medical management and facilitate communication between patients and caregivers.
Orbit Transfer Vehicle (OTV) advanced expander cycle engine point design study, volume 2
NASA Technical Reports Server (NTRS)
1981-01-01
The engine requirements are emphasized and include: high specific impulse within a restricted installed length constraint, long life, multiple starts, different thrust levels, and man-rated reliability. The engine operating characteristics and the major component analytical design are summarized.
Evaluation of tools used to measure calcium and/or dairy consumption in adults.
Magarey, Anthea; Baulderstone, Lauren; Yaxley, Alison; Markow, Kylie; Miller, Michelle
2015-05-01
To identify and critique tools for the assessment of Ca and/or dairy intake in adults, in order to ascertain the most accurate and reliable tools available. A systematic review of the literature was conducted using defined inclusion and exclusion criteria. Articles reporting on originally developed tools or testing the reliability or validity of existing tools that measure Ca and/or dairy intake in adults were included. Author-defined criteria for reporting reliability and validity properties were applied. Studies conducted in Western countries. Adults. Thirty papers, utilising thirty-six tools assessing intake of dairy, Ca or both, were identified. Reliability testing was conducted on only two dairy and five Ca tools, with results indicating that only one dairy and two Ca tools were reliable. Validity testing was conducted for all but four Ca-only tools. There was high reliance in validity testing on lower-order tests such as correlation and failure to differentiate between statistical and clinically meaningful differences. Results of the validity testing suggest one dairy and five Ca tools are valid. Thus one tool was considered both reliable and valid for the assessment of dairy intake and only two tools proved reliable and valid for the assessment of Ca intake. While several tools are reliable and valid, their application across adult populations is limited by the populations in which they were tested. These results indicate a need for tools that assess Ca and/or dairy intake in adults to be rigorously tested for reliability and validity.
Hintersteiner, Ingrid; Himmelsbach, Markus; Buchberger, Wolfgang W
2015-02-01
In recent years, the development of reliable methods for the quantitation of microplastics in different samples, including evaluating the particles' adverse effects in the marine environment, has become a great concern. Because polyolefins are the most prevalent type of polymer in personal-care products containing microplastics, this study presents a novel approach for their quantitation. The method is suitable for aqueous and hydrocarbon-based products, and includes a rapid sample clean-up involving twofold density separation and a subsequent quantitation with high-temperature gel-permeation chromatography. In contrast with previous procedures, both errors caused by weighing after insufficient separation of plastics and matrix and time-consuming visual sorting are avoided. In addition to reliable quantitative results, in this investigation a comprehensive characterization of the polymer particles isolated from the product matrix, covering size, shape, molecular weight distribution and stabilization, is provided. Results for seven different personal-care products are presented. Recoveries of this method were in the range of 92-96 %.
Roghani, Taybeh; Khalkhali Zavieh, Minoo; Rahimi, Abbas; Talebian, Saeed; Manshadi, Farideh Dehghan; Akbarzadeh Baghban, Alireza; King, Nicole; Katzman, Wendy
2018-01-25
The purpose of this study was to investigate the intra-rater reliability and validity of a designed load cell setup for the measurement of back extensor muscle force and endurance. The study sample included 19 older women with hyperkyphosis, mean age 67.0 ± 5.0 years, and 14 older women without hyperkyphosis, mean age 63.0 ± 6.0 years. Maximum back extensor force and endurance were measured in a sitting position with a designed load cell setup. Tests were performed by the same examiner on two separate days within a 72-hour interval. The intra-rater reliability of the measurements was analyzed using intraclass correlation coefficient (ICC), standard errors of measurement (SEM), and minimal detectable change (MDC). The validity of the setup was determined using Pearson correlation analysis and independent t-test. Using our designed load cell, the values of ICC indicated very high reliability of force measurement (hyperkyphosis group: 0.96, normal group: 0.97) and high reliability of endurance measurement (hyperkyphosis group: 0.82, normal group: 0.89). For all tests, the values of SEM and MDC were low in both groups. A significant correlation between two documented forces (load cell force and target force) and significant differences in the muscle force and endurance among the two groups were found. The measurements of static back muscle force and endurance are reliable and valid with our designed setup in older women with and without hyperkyphosis.
Pediatric Amblyopia Risk Investigation Study (PARIS).
Savage, Howard I; Lee, Hester H; Zaetta, Deneen; Olszowy, Ronald; Hamburger, Ellie; Weissman, Mark; Frick, Kevin
2005-12-01
To assess the learning curve, testability, and reliability of vision screening modalities administered by pediatric health extenders. Prospective masked clinical trial. Two hundred subjects aged 3 to 6 underwent timed screening for amblyopia by physician extenders, including LEA visual acuity (LEA), stereopsis (RDE), and noncycloplegic autorefraction (NCAR). Patients returned for a comprehensive diagnostic eye examination performed by an ophthalmologist or optometrist. Average screening time was 5.4 +/- 1.6 minutes (LEA), 1.9 +/- 0.9 minutes (RDE), and 1.7 +/- 1.0 minutes (NCAR). Test time for NCAR and RDE fell by 40% during the study period. Overall testability was 92% (LEA), 96% (RDE), and 94% (NCAR). Testability among 3-year-olds was 73% (LEA), 96% (RDE), and 89% (NCAR). Reliability of LEA was moderate (r = .59). Reliability of NCAR was high for astigmatism (Cyl) (r = .89), moderate for spherical equivalent (SE) (r = .66), and low for anisometropia (ANISO) (r = .38). Correlation of cycloplegic autorefraction (CAR) with gold standard cycloplegic retinoscopic refraction (CRR) was very high for SE (.85), CYL (.77), and moderate for ANISO (.48). With NCAR, physician extenders can quickly and reliably detect astigmatism and spherical refractive error in one-third the time it takes to obtain visual acuity. LEA has a lower initial cost, but is time consuming, moderately reliable, and more difficult for 3-year-olds. Shorter examination time and higher reliability may make NCAR a more efficient screening tool for refractive amblyopia in younger children. Future study is needed to determine the sensitivity and specificity of NCAR and other screening methods in detecting amblyopia and amblyopia risk factors.
Characterizing wind power resource reliability in southern Africa
Fant, Charles; Gunturu, Bhaskar; Schlosser, Adam
2015-08-29
Producing electricity from wind is attractive because it provides a clean, low-maintenance power supply. However, wind resource is intermittent on various timescales, thus occasionally introducing large and sudden changes in power supply. A better understanding of this variability can greatly benefit power grid planning. In the following study, wind resource is characterized using metrics that highlight these intermittency issues; therefore identifying areas of high and low wind power reliability in southern Africa and Kenya at different time-scales. After developing a wind speed profile, these metrics are applied at various heights in order to assess the added benefit of raising themore » wind turbine hub. Furthermore, since the interconnection of wind farms can aid in reducing the overall intermittency, the value of interconnecting near-by sites is mapped using two distinct methods. Of the countries in this region, the Republic of South Africa has shown the most interest in wind power investment. For this reason, we focus parts of the study on wind reliability in the country. The study finds that, although mean Wind Power Density is high in South Africa compared to its neighboring countries, wind power resource tends to be less reliable than in other parts of southern Africa—namely central Tanzania. We also find that South Africa’s potential varies over different timescales, with higher reliability in the summer than winter, and higher reliability during the day than at night. This study is concluded by introducing two methods and measures to characterize the value of interconnection, including the use of principal component analysis to identify areas with a common signal.« less
Sawchuk, Dena; Currie, Kris; Vich, Manuel Lagravere; Palomo, Juan Martin
2016-01-01
Objective To evaluate the accuracy and reliability of the diagnostic tools available for assessing maxillary transverse deficiencies. Methods An electronic search of three databases was performed from their date of establishment to April 2015, with manual searching of reference lists of relevant articles. Articles were considered for inclusion if they reported the accuracy or reliability of a diagnostic method or evaluation technique for maxillary transverse dimensions in mixed or permanent dentitions. Risk of bias was assessed in the included articles, using the Quality Assessment of Diagnostic Accuracy Studies tool-2. Results Nine articles were selected. The studies were heterogeneous, with moderate to low methodological quality, and all had a high risk of bias. Four suggested that the use of arch width prediction indices with dental cast measurements is unreliable for use in diagnosis. Frontal cephalograms derived from cone-beam computed tomography (CBCT) images were reportedly more reliable for assessing intermaxillary transverse discrepancies than posteroanterior cephalograms. Two studies proposed new three-dimensional transverse analyses with CBCT images that were reportedly reliable, but have not been validated for clinical sensitivity or specificity. No studies reported sensitivity, specificity, positive or negative predictive values or likelihood ratios, or ROC curves of the methods for the diagnosis of transverse deficiencies. Conclusions Current evidence does not enable solid conclusions to be drawn, owing to a lack of reliable high quality diagnostic studies evaluating maxillary transverse deficiencies. CBCT images are reportedly more reliable for diagnosis, but further validation is required to confirm CBCT's accuracy and diagnostic superiority. PMID:27668196
Characterizing wind power resource reliability in southern Africa
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fant, Charles; Gunturu, Bhaskar; Schlosser, Adam
Producing electricity from wind is attractive because it provides a clean, low-maintenance power supply. However, wind resource is intermittent on various timescales, thus occasionally introducing large and sudden changes in power supply. A better understanding of this variability can greatly benefit power grid planning. In the following study, wind resource is characterized using metrics that highlight these intermittency issues; therefore identifying areas of high and low wind power reliability in southern Africa and Kenya at different time-scales. After developing a wind speed profile, these metrics are applied at various heights in order to assess the added benefit of raising themore » wind turbine hub. Furthermore, since the interconnection of wind farms can aid in reducing the overall intermittency, the value of interconnecting near-by sites is mapped using two distinct methods. Of the countries in this region, the Republic of South Africa has shown the most interest in wind power investment. For this reason, we focus parts of the study on wind reliability in the country. The study finds that, although mean Wind Power Density is high in South Africa compared to its neighboring countries, wind power resource tends to be less reliable than in other parts of southern Africa—namely central Tanzania. We also find that South Africa’s potential varies over different timescales, with higher reliability in the summer than winter, and higher reliability during the day than at night. This study is concluded by introducing two methods and measures to characterize the value of interconnection, including the use of principal component analysis to identify areas with a common signal.« less
Translations on USSR Science and Technology, Physical Sciences and Technology, Number 16
1977-08-05
34INVESTIGATION OF SPLITTING OF LIGHT NUCLEI WITH HIGH-ENERGY y -RAYS WITH THE METHOD OF WILSON’S CHAMBER OPERATING IN POWERFUL BEAMS OF ELECTRONIC...boast high reliability, high speed, and extremely modest power requirements. Information oh the Screen Visual display devices greatly facilitate...area of application of these units Includes navigation, control of power systems, machine tools, and manufac- turing processes. Th» ^»abilities of
Reliability program requirements for aeronautical and space system contractors
NASA Technical Reports Server (NTRS)
1987-01-01
General reliability program requirements for NASA contracts involving the design, development, fabrication, test, and/or use of aeronautical and space systems including critical ground support equipment are prescribed. The reliability program requirements require (1) thorough planning and effective management of the reliability effort; (2) definition of the major reliability tasks and their place as an integral part of the design and development process; (3) planning and evaluating the reliability of the system and its elements (including effects of software interfaces) through a program of analysis, review, and test; and (4) timely status indication by formal documentation and other reporting to facilitate control of the reliability program.
Ries, Julie D; Echternach, John L; Nof, Leah; Gagnon Blodgett, Michelle
2009-06-01
With the increasing incidence of Alzheimer disease (AD), determining the validity and reliability of outcome measures for people with this disease is necessary. The goals of this study were to assess test-retest reliability of data for the Timed "Up & Go" Test (TUG), the Six-Minute Walk Test (6MWT), and gait speed and to calculate minimal detectable change (MDC) scores for each outcome measure. Performance differences between groups with mild to moderate AD and moderately severe to severe AD (as determined by the Functional Assessment Staging [FAST] scale) were studied. This was a prospective, nonexperimental, descriptive methodological study. Background data collected for 51 people with AD included: use of an assistive device, Mini-Mental Status Examination scores, and FAST scale scores. Each participant engaged in 2 test sessions, separated by a 30- to 60-minute rest period, which included 2 TUG trials, 1 6MWT trial, and 2 gait speed trials using a computerized gait assessment system. A specific cuing protocol was followed to achieve optimal performance during test sessions. Test-retest reliability values for the TUG, the 6MWT, and gait speed were high for all participants together and for the mild to moderate AD and moderately severe to severe AD groups separately (intraclass correlation coefficients > or = .973); however, individual variability of performance also was high. Calculated MDC scores at the 90% confidence interval were: TUG=4.09 seconds, 6MWT=33.5 m (110 ft), and gait speed=9.4 cm/s. The 2 groups were significantly different in performance of clinical tests, with the participants who were more cognitively impaired being more physically and functionally impaired. A single researcher for data collection limited sample numbers and prohibited blinding to dementia level. The TUG, the 6MWT, and gait speed are reliable outcome measures for use with people with AD, recognizing that individual variability of performance is high. Minimal detectable change scores at the 90% confidence interval can be used to assess change in performance over time and the impact of treatment.
Performance Enhancement of a High Speed Jet Impingement System for Nonvolatile Residue Removal
NASA Technical Reports Server (NTRS)
Klausner, James F.; Mei, Renwei; Near, Steve; Stith, Rex
1996-01-01
A high speed jet impingement cleaning facility has been developed to study the effectiveness of the nonvolatile residue removal. The facility includes a high pressure air compressor which charges the k-bottles to supply high pressure air, an air heating section to vary the temperature of the high pressure air, an air-water mixing chamber to meter the water flow and generate small size droplets, and a converging- diverging nozzle to deliver the supersonic air-droplet mixture flow to the cleaning surface. To reliably quantify the cleanliness of the surface, a simple procedure for measurement and calibration is developed to relate the amount of the residue on the surface to the relative change in the reflectivity between a clean surface and the greased surface. This calibration procedure is economical, simple, reliable, and robust. a theoretical framework is developed to provide qualitative guidance for the design of the test and interpretation of the experimental results. The result documented in this report support the theoretical considerations.
Gorgos, Kara S; Wasylyk, Nicole T; Van Lunen, Bonnie L; Hoch, Matthew C
2014-04-01
Joint mobilizations are commonly used by clinicians to decrease pain and restore joint arthrokinematics following musculoskeletal injury. The force applied during a joint mobilization treatment is subjective to the individual clinician but may have an effect on patient outcomes. The purpose of this systematic review was to critically appraise and synthesize the studies which examined the reliability of clinicians' force application during joint mobilization. A systematic search of PubMed and EBSCO Host databases from inception to March 1, 2013 was conducted to identify studies assessing the reliability of force application during joint mobilizations. Two reviewers utilized the Quality Appraisal of Reliability Studies (QAREL) assessment tool to determine the quality of included studies. The relative reliability of the included studies was examined through intraclass correlation coefficients (ICC) to synthesize study findings. All results were collated qualitatively with a level of evidence approach. A total of seven studies met the eligibility and were included. Five studies were included that assessed inter-clinician reliability, and six studies were included that assessed intra-clinician reliability. The overall level of evidence for inter-clinician reliability was strong for poor-to-moderate reliability (ICC = -0.04 to 0.70). The overall level of evidence for intra-clinician reliability was strong for good reliability (ICC = 0.75-0.99). This systematic review indicates there is variability in force application between clinicians but individual clinicians apply forces consistently. The results of this systematic review suggest innovative instructional methods are needed to improve consistency and validate the forces applied during of joint mobilization treatments. This is particularly evident for improving the consistency of force application across clinicians. Copyright © 2014 Elsevier Ltd. All rights reserved.
Interformat reliability of digital psychiatric self-report questionnaires: a systematic review.
Alfonsson, Sven; Maathz, Pernilla; Hursti, Timo
2014-12-03
Research on Internet-based interventions typically use digital versions of pen and paper self-report symptom scales. However, adaptation into the digital format could affect the psychometric properties of established self-report scales. Several studies have investigated differences between digital and pen and paper versions of instruments, but no systematic review of the results has yet been done. This review aims to assess the interformat reliability of self-report symptom scales used in digital or online psychotherapy research. Three databases (MEDLINE, Embase, and PsycINFO) were systematically reviewed for studies investigating the reliability between digital and pen and paper versions of psychiatric symptom scales. From a total of 1504 publications, 33 were included in the review, and interformat reliability of 40 different symptom scales was assessed. Significant differences in mean total scores between formats were found in 10 of 62 analyses. These differences were found in just a few studies, which indicates that the results were due to study effects and sample effects rather than unreliable instruments. The interformat reliability ranged from r=.35 to r=.99; however, the majority of instruments showed a strong correlation between format scores. The quality of the included studies varied, and several studies had insufficient power to detect small differences between formats. When digital versions of self-report symptom scales are compared to pen and paper versions, most scales show high interformat reliability. This supports the reliability of results obtained in psychotherapy research on the Internet and the comparability of the results to traditional psychotherapy research. There are, however, some instruments that consistently show low interformat reliability, suggesting that these conclusions cannot be generalized to all questionnaires. Most studies had at least some methodological issues with insufficient statistical power being the most common issue. Future studies should preferably provide information about the transformation of the instrument into digital format and the procedure for data collection in more detail.
Creating Highly Reliable Accountable Care Organizations.
Vogus, Timothy J; Singer, Sara J
2016-12-01
Accountable Care Organizations' (ACOs) pursuit of the triple aim of higher quality, lower cost, and improved population health has met with mixed results. To improve the design and implementation of ACOs we look to organizations that manage similarly complex, dynamic, and tightly coupled conditions while sustaining exceptional performance known as high-reliability organizations. We describe the key processes through which organizations achieve reliability, the leadership and organizational practices that enable it, and the role that professionals can play when charged with enacting it. Specifically, we present concrete practices and processes from health care organizations pursuing high-reliability and from early ACOs to illustrate how the triple aim may be met by cultivating mindful organizing, practicing reliability-enhancing leadership, and identifying and supporting reliability professionals. We conclude by proposing a set of research questions to advance the study of ACOs and high-reliability research. © The Author(s) 2016.
NASA Astrophysics Data System (ADS)
Irwanto, Rohaeti, Eli; LFX, Endang Widjajanti; Suyanta
2017-05-01
This research aims to develop instrument and determine the characteristics of an integrated assessment instrument. This research uses 4-D model, which includes define, design, develop, and disseminate. The primary product is validated by expert judgment, tested it's readability by students, and assessed it's feasibility by chemistry teachers. This research involved 246 students of grade XI of four senior high schools in Yogyakarta, Indonesia. Data collection techniques include interview, questionnaire, and test. Data collection instruments include interview guideline, item validation sheet, users' response questionnaire, instrument readability questionnaire, and essay test. The results show that the integrated assessment instrument has Aiken validity value of 0.95. Item reliability was 0.99 and person reliability was 0.69. Teachers' response to the integrated assessment instrument is very good. Therefore, the integrated assessment instrument is feasible to be applied to measure the students' analytical thinking and science process skills.
Hunt, Toby; Williams, Marie T; Olds, Tim S
2013-01-01
To determine the reliability and validity of the Multimedia Activity Recall for Children and Adults (MARCA) in people with chronic obstructive pulmonary disease (COPD). People with COPD and their carers completed the Multimedia Activity Recall for Children and Adults (MARCA) for four, 24-hour periods (including test-retest of 2 days) while wearing a triaxial accelerometer (Actigraph GT3X+®), a multi-sensor armband (Sensewear Pro3®) and a pedometer (New Lifestyles 1000®). Self reported activity recalls (MARCA) and objective activity monitoring (Accelerometry) were recorded under free-living conditions. 24 couples were included in the analysis (COPD; age 74.4 ± 7.9 yrs, FEV1 54 ± 13% Carer; age 69.6 ± 10.9 yrs, FEV1 99 ± 24%). Not applicable. Test-retest reliability was compared for MARCA activity domains and different energy expenditure zones. Validity was assessed between MARCA-derived physical activity level (in metabolic equivalent of task (MET) per minute), duration of moderate to vigorous physical activity (min) and related data from the objective measurement devices. Analysis included intra-class correlation coefficients (ICC), Bland-Altman analyses, paired t-tests (p) and Spearman's rank correlation coefficients (rs). Reliability between occasions of recall for all activity domains was uniformly high, with test-retest correlations consistently >0.9. Validity correlations were moderate to strong (rs = 0.43-0.80) across all comparisons. The MARCA yields comparable PAL estimates and slightly higher moderate to vigorous physical activity (MVPA) estimates. In older adults with chronic illness, the MARCA is a valid and reliable tool for capturing not only the time and energy expenditure associated with physical and sedentary activities but also information on the types of activities.
Evaluating the use of in-store measures in retail food stores and restaurants in Brazil.
Duran, Ana Clara; Lock, Karen; Latorre, Maria do Rosario D O; Jaime, Patricia Constante
2015-01-01
To assess inter-rater reliability, test-retest reliability, and construct validity of retail food store, open-air food market, and restaurant observation tools adapted to the Brazilian urban context. This study is part of a cross-sectional observation survey conducted in 13 districts across the city of Sao Paulo, Brazil in 2010-2011. Food store and restaurant observational tools were developed based on previously available tools, and then tested it. They included measures on the availability, variety, quality, pricing, and promotion of fruits and vegetables and ultra-processed foods. We used Kappa statistics and intra-class correlation coefficients to assess inter-rater and test-retest reliabilities in samples of 142 restaurants, 97 retail food stores (including open-air food markets), and of 62 restaurants and 45 retail food stores (including open-air food markets), respectively. Construct validity as the tool's abilities to discriminate based on store types and different income contexts were assessed in the entire sample: 305 retail food stores, 8 fruits and vegetable markets, and 472 restaurants. Inter-rater and test-retest reliability were generally high, with most Kappa values greater than 0.70 (range 0.49-1.00). Both tools discriminated between store types and neighborhoods with different median income. Fruits and vegetables were more likely to be found in middle to higher-income neighborhoods, while soda, fruit-flavored drink mixes, cookies, and chips were cheaper and more likely to be found in lower-income neighborhoods. The measures were reliable and able to reveal significant differences across store types and different contexts. Although some items may require revision, results suggest that the tools may be used to reliably measure the food stores and restaurant food environment in urban settings of middle-income countries. Such studies can help .inform health promotion interventions and policies in these contexts.
Evaluating the use of in-store measures in retail food stores and restaurants in Brazil
Duran, Ana Clara; Lock, Karen; Latorre, Maria do Rosario D O; Jaime, Patricia Constante
2015-01-01
ABSTRACT OBJECTIVE To assess inter-rater reliability, test-retest reliability, and construct validity of retail food store, open-air food market, and restaurant observation tools adapted to the Brazilian urban context. METHODS This study is part of a cross-sectional observation survey conducted in 13 districts across the city of Sao Paulo, Brazil in 2010-2011. Food store and restaurant observational tools were developed based on previously available tools, and then tested it. They included measures on the availability, variety, quality, pricing, and promotion of fruits and vegetables and ultra-processed foods. We used Kappa statistics and intra-class correlation coefficients to assess inter-rater and test-retest reliabilities in samples of 142 restaurants, 97 retail food stores (including open-air food markets), and of 62 restaurants and 45 retail food stores (including open-air food markets), respectively. Construct validity as the tool’s abilities to discriminate based on store types and different income contexts were assessed in the entire sample: 305 retail food stores, 8 fruits and vegetable markets, and 472 restaurants. RESULTS Inter-rater and test-retest reliability were generally high, with most Kappa values greater than 0.70 (range 0.49-1.00). Both tools discriminated between store types and neighborhoods with different median income. Fruits and vegetables were more likely to be found in middle to higher-income neighborhoods, while soda, fruit-flavored drink mixes, cookies, and chips were cheaper and more likely to be found in lower-income neighborhoods. CONCLUSIONS The measures were reliable and able to reveal significant differences across store types and different contexts. Although some items may require revision, results suggest that the tools may be used to reliably measure the food stores and restaurant food environment in urban settings of middle-income countries. Such studies can help .inform health promotion interventions and policies in these contexts. PMID:26538101
Reliability of the Melbourne assessment of unilateral upper limb function.
Randall, M; Carlin, J B; Chondros, P; Reddihough, D
2001-11-01
This study examines the reliability of the Melbourne Assessment of Unilateral Upper Limb Function: a quantitative test of quality of movement in children with neurological impairment. The assessment was administered to 20 children aged from 5 to 16 years (mean age 9 years 10 months, SD 2 years 10 months) who had various types and degrees of cerebral palsy (CP). The performances of the 20 children during assessment were videotaped for subsequent scoring by 15 occupational therapists. Scores were analyzed for internal consistency of test items, inter- and intrarater reliability of scorings of the same videotapes, and test-retest reliability using repeat videotaping. Results revealed very high internal consistency of test items (alpha=0.96), moderate to high agreement both within and between raters for all test items (intraclass correlations of at least 0.7) apart from item 16 (hand to mouth and down), and high interrater reliability (0.95) and intrarater reliability (0.97) for total test scores. Test-retest results revealed moderate to high intrarater reliability for item totals (mean of 0.83 and 0.79) for each rater and high reliability for test totals (0.98 and 0.97). These findings indicate that the Melbourne Assessment of Unilateral Upper Limb Function is a reliable tool for measuring the quality of unilateral upper-limb movement in children with CP.
NASA Technical Reports Server (NTRS)
Reed, R. P.
1972-01-01
The elastic and plastic deformation behavior of high-purity aluminum and of dilute aluminum alloys is reviewed. Reliable property data, including elastic moduli, elastic coefficients, tensile, creep, fatigue, hardness, and impact are presented. Single crystal tensile results are discussed. Rather comprehensive reference lists, containing publications of the past 20 years, are included for each of the above categories. Defect structures and mechanisms responsible for mechanical behavior are presented. Strengthening techniques (alloys, cold work, irradiation, quenching, composites) and recovery are briefly reviewed.
NASA Astrophysics Data System (ADS)
Yu, Long; Xu, Juanjuan; Zhang, Lifang; Xu, Xiaogang
2018-03-01
Based on stress-strength interference theory to establish the reliability mathematical model for high temperature and high pressure multi-stage decompression control valve (HMDCV), and introduced to the temperature correction coefficient for revising material fatigue limit at high temperature. Reliability of key dangerous components and fatigue sensitivity curve of each component are calculated and analyzed by the means, which are analyzed the fatigue life of control valve and combined with reliability theory of control valve model. The impact proportion of each component on the control valve system fatigue failure was obtained. The results is shown that temperature correction factor makes the theoretical calculations of reliability more accurate, prediction life expectancy of main pressure parts accords with the technical requirements, and valve body and the sleeve have obvious influence on control system reliability, the stress concentration in key part of control valve can be reduced in the design process by improving structure.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-25
...-high, 2,932-foot-long earth embankment dam; (2) an upper reservoir with a surface area of 27.5 acres and an 2,262 acre-foot storage capacity; (3) a 120-foot-high, 2,475-foot-long earth embankment dam..., using the eComment system at http://www.ferc.gov/docs-filing/ecomment.asp . You must include your name...
The GeoEye Satellite Constellation
NASA Technical Reports Server (NTRS)
Dial, Gene; Cole, Aaron; Lutes, James; McKune, John; Martinez, Mike; Rao, R. S.; Taylor, Martin
2007-01-01
The GeoEye Constellation consists of: a) IKONOS and OrbView-3 for high resolution; b) GeoEye with higher resolution 1Q2007; c) RESOUCESAT-1 for global crop assessment; d) OrbView-2 for ocean research and fish. IKONOS performance in 2005 included stable image quality, radiometry and geometric accuracy. reliability is 80% to 2008. Demonstrated capacity for high-volume, quick-response collection and production.
Feasibility of groundwater recharge dam projects in arid environments
NASA Astrophysics Data System (ADS)
Jaafar, H. H.
2014-05-01
A new method for determining feasibility and prioritizing investments for agricultural and domestic recharge dams in arid regions is developed and presented. The method is based on identifying the factors affecting the decision making process and evaluating these factors, followed by determining the indices in a GIS-aided environment. Evaluated parameters include results from field surveys and site visits, land cover and soils data, precipitation data, runoff data and modeling, number of beneficiaries, domestic irrigation demand, reservoir objectives, demography, reservoirs yield and reliability, dam structures, construction costs, and operation and maintenance costs. Results of a case study on more than eighty proposed dams indicate that assessment of reliability, annualized cost/demand satisfied and yield is crucial prior to investment decision making in arid areas. Irrigation demand is the major influencing parameter on yield and reliability of recharge dams, even when only 3 months of the demand were included. Reliability of the proposed reservoirs as related to their standardized size and net inflow was found to increase with increasing yield. High priority dams were less than 4% of the total, and less priority dams amounted to 23%, with the remaining found to be not feasible. The results of this methodology and its application has proved effective in guiding stakeholders for defining most favorable sites for preliminary and detailed design studies and commissioning.
Florida Journal of Communication Disorders, 1999.
ERIC Educational Resources Information Center
Lundy, Donna S., Ed.
1999-01-01
This issue contains eight articles that represent information on a variety of highly specialized topics involving communicative sciences. Articles include: (1) "The Reliability of the Kay Elemetrics Multidimensional Voice Program (MDVP) for Acoustic Analysis of the Normal Voice" (Ann Marie Cimino and Christine M. Sapienza), which focuses on the…
MacDonald, James; Wilson, Julie; Young, Julie; Duerson, Drew; Swisher, Gail; Collins, Christy L; Meehan, William P
2015-01-01
A common sequela of concussions is impaired reaction time. Computerized neurocognitive tests commonly measure reaction time. A simple clinical test for reaction time has been studied previously in college athletes; whether this test is valid and reliable when assessing younger athletes remains unknown. Our study examines the reliability and validity of this test in a population of high school athletes. Cross-sectional study. Two American High Schools. High school athletes (N = 448) participating in American football or soccer during the academic years 2011 to 2012 and 2012 to 2013. All study participants completed a computerized baseline neurocognitive assessment that included a measure of reaction time (RT comp), in addition to a clinical measure of reaction time that assessed how far a standard measuring device would fall prior to the athlete catching it (RT clin). Validity was assessed by determining the correlation between RT clin and RT comp. Reliability was assessed by measuring the intraclass correlation coefficients (ICCs) between the repeated measures of RT clin and RT comp taken 1 year apart. In the first year of study, RT clin and RT comp were positively but weakly correlated (rs = 0.229, P < 0.001). In the second year, there was no significant correlation between RT clin and RT comp (rs = 0.084, P = 0.084). Both RT clin [ICC = 0.608; 95% confidence interval (CI), 0.434-0.728] and RT comp (ICC = 0.691; 95% CI, 0.554-0.786) had marginal reliability. In a population of high school athletes, RT clin had poor validity when compared with RT comp as a standard. Both RT clin and RT comp had marginal test-retest reliability. Before considering the clinical use of RT clin in the assessment of sport-related concussions sustained by high school athletes, the factors affecting reliability and validity should be investigated further. Reaction time impairment commonly results from concussion and is among the most clinically important measures of the condition. The device evaluated in this study has previously been investigated as a reaction time measure in college athletes. This study investigates the clinical generalizability of the device in a younger population. A video abstract showing how the RT clin device is used in practice is available as Supplemental Digital Content 1, http://links.lww.com/JSM/A43.
NASA Technical Reports Server (NTRS)
Wild, Christian; Eckhardt, Dave
1987-01-01
The development of a methodology for the production of highly reliable software is one of the greatest challenges facing the computer industry. Meeting this challenge will undoubtably involve the integration of many technologies. This paper describes the use of Artificial Intelligence technologies in the automated analysis of the formal algebraic specifications of abstract data types. These technologies include symbolic execution of specifications using techniques of automated deduction and machine learning through the use of examples. On-going research into the role of knowledge representation and problem solving in the process of developing software is also discussed.
Electrical insulation design requirements and reliability goals
NASA Astrophysics Data System (ADS)
Ross, R. G., Jr.
1983-11-01
The solar cells in a photovoltaic module which must be electrically isolated from module exterior surfaces to satisfy a variety of safety and operating considerations are discussed. The performance and reliability of the insulation system are examined. Technical requirements involve the capability of withstanding the differential voltage from the solar cells to the module frame. The maximum system voltage includes consideration of maximum open circuit array voltages achieved under low-temperature, high-irradiance conditions, and transient overvoltages due to system feedback of lightning transients. The latter is bounded by the characteristics of incorporated voltage limiting devices such as MOVs.
Requirements for conformal coating and staking of printed wiring boards and electronic assemblies
NASA Technical Reports Server (NTRS)
1985-01-01
In order to maintain the high standards of the NASA conformal coating and staking program, this publication: prescribes NASA's requirements for assuring reliable conformal coating and staking for printed wiring boards and electronic assemblies; describes and incorporates basic considerations necessary to assure reliable conformal coating and staking; establishes the supplier's responsibility to train and certify personnel; provides for supplier documentation of the fabrication and inspection procedures to be used for NASA work, including supplier innovations and changes in technology; and provides visual workmanship standards to aid those responsible for determining quality conformance to the established requirements.
Status of high polarization DC high voltage Gallium Arsenide photoelectron guns
DOE Office of Scientific and Technical Information (OSTI.GOV)
M. Poelker, P. Adderley, J. Brittian, J. Clark, J. Grames, J. Hansknecht, J. McCarter, M. Stutzman, R. Suleiman, K. Surles-Law
2008-01-01
Users receive very high beam polarization from reliable GaAs photoelectron guns at facilities worldwide. Satisfaction with beam quality (and a number of lab closures) has reduced the level of polarized source R&D from the heyday of 1990s. However, new experiments and new accelerators proposals including high current unpolarized machines, require GaAs photoguns with capabilities that exceed today's state of the art. This submission describes the capabilities of today's high- polarization DC high voltage GaAs photoguns and discusses issues that must be addressed to meet new demands.
Donnelly, Lane F
Deploying an intentional daily management process is a key part to create high-reliability culture. Key components described in the literature for a successfully daily management process include leadership standard work, visual controls, daily accountability processes, and the discipline to stick to the process over the long term. We believe that the institution of a daily readiness huddle has helped us better coordinate and communicate as a department and improved our ability to deliver imaging services on a daily basis. The daily readiness huddle has enabled us to more rapidly identify issues and has brought accountability to seeing solutions to those issues brought to fruition. In addition, it has helped with team building, including between the radiologists and the nonphysician staff. Copyright © 2017 Elsevier Inc. All rights reserved.
Lucas, Nicholas; Macaskill, Petra; Irwig, Les; Moran, Robert; Bogduk, Nikolai
2009-01-01
Trigger points are promoted as an important cause of musculoskeletal pain. There is no accepted reference standard for the diagnosis of trigger points, and data on the reliability of physical examination for trigger points are conflicting. To systematically review the literature on the reliability of physical examination for the diagnosis of trigger points. MEDLINE, EMBASE, and other sources were searched for articles reporting the reliability of physical examination for trigger points. Included studies were evaluated for their quality and applicability, and reliability estimates were extracted and reported. Nine studies were eligible for inclusion. None satisfied all quality and applicability criteria. No study specifically reported reliability for the identification of the location of active trigger points in the muscles of symptomatic participants. Reliability estimates varied widely for each diagnostic sign, for each muscle, and across each study. Reliability estimates were generally higher for subjective signs such as tenderness (kappa range, 0.22-1.0) and pain reproduction (kappa range, 0.57-1.00), and lower for objective signs such as the taut band (kappa range, -0.08-0.75) and local twitch response (kappa range, -0.05-0.57). No study to date has reported the reliability of trigger point diagnosis according to the currently proposed criteria. On the basis of the limited number of studies available, and significant problems with their design, reporting, statistical integrity, and clinical applicability, physical examination cannot currently be recommended as a reliable test for the diagnosis of trigger points. The reliability of trigger point diagnosis needs to be further investigated with studies of high quality that use current diagnostic criteria in clinically relevant patients.
Aragón, Mônica L C; Pontes, Luana F; Bichara, Lívia M; Flores-Mir, Carlos; Normando, David
2016-08-01
The development of 3D technology and the trend of increasing the use of intraoral scanners in dental office routine lead to the need for comparisons with conventional techniques. To determine if intra- and inter-arch measurements from digital dental models acquired by an intraoral scanner are as reliable and valid as the similar measurements achieved from dental models obtained through conventional intraoral impressions. An unrestricted electronic search of seven databases until February 2015. Studies that focused on the accuracy and reliability of images obtained from intraoral scanners compared to images obtained from conventional impressions. After study selection the QUADAS risk of bias assessment tool for diagnostic studies was used to assess the risk of bias (RoB) among the included studies. Four articles were included in the qualitative synthesis. The scanners evaluated were OrthoProof, Lava, iOC intraoral, Lava COS, iTero and D250. These studies evaluated the reliability of tooth widths, Bolton ratio measurements, and image superimposition. Two studies were classified as having low RoB; one had moderate RoB and the remaining one had high RoB. Only one study evaluated the time required to complete clinical procedures and patient's opinion about the procedure. Patients reported feeling more comfortable with the conventional dental impression method. Associated costs were not considered in any of the included study. Inter- and intra-arch measurements from digital models produced from intraoral scans appeared to be reliable and accurate in comparison to those from conventional impressions. This assessment only applies to the intraoral scanners models considered in the finally included studies. Digital models produced by intraoral scan eliminate the need of impressions materials; however, currently, longer time is needed to take the digital images. PROSPERO (CRD42014009702). None. © The Author 2016. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.
NASA Technical Reports Server (NTRS)
Shooman, Martin L.
1991-01-01
Many of the most challenging reliability problems of our present decade involve complex distributed systems such as interconnected telephone switching computers, air traffic control centers, aircraft and space vehicles, and local area and wide area computer networks. In addition to the challenge of complexity, modern fault-tolerant computer systems require very high levels of reliability, e.g., avionic computers with MTTF goals of one billion hours. Most analysts find that it is too difficult to model such complex systems without computer aided design programs. In response to this need, NASA has developed a suite of computer aided reliability modeling programs beginning with CARE 3 and including a group of new programs such as: HARP, HARP-PC, Reliability Analysts Workbench (Combination of model solvers SURE, STEM, PAWS, and common front-end model ASSIST), and the Fault Tree Compiler. The HARP program is studied and how well the user can model systems using this program is investigated. One of the important objectives will be to study how user friendly this program is, e.g., how easy it is to model the system, provide the input information, and interpret the results. The experiences of the author and his graduate students who used HARP in two graduate courses are described. Some brief comparisons were made with the ARIES program which the students also used. Theoretical studies of the modeling techniques used in HARP are also included. Of course no answer can be any more accurate than the fidelity of the model, thus an Appendix is included which discusses modeling accuracy. A broad viewpoint is taken and all problems which occurred in the use of HARP are discussed. Such problems include: computer system problems, installation manual problems, user manual problems, program inconsistencies, program limitations, confusing notation, long run times, accuracy problems, etc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Xiangqi; Zhang, Yingchen
This paper presents an optimal voltage control methodology with coordination among different voltage-regulating resources, including controllable loads, distributed energy resources such as energy storage and photovoltaics (PV), and utility voltage-regulating devices such as voltage regulators and capacitors. The proposed methodology could effectively tackle the overvoltage and voltage regulation device distortion problems brought by high penetrations of PV to improve grid operation reliability. A voltage-load sensitivity matrix and voltage-regulator sensitivity matrix are used to deploy the resources along the feeder to achieve the control objectives. Mixed-integer nonlinear programming is used to solve the formulated optimization control problem. The methodology has beenmore » tested on the IEEE 123-feeder test system, and the results demonstrate that the proposed approach could actively tackle the voltage problem brought about by high penetrations of PV and improve the reliability of distribution system operation.« less
NASA Technical Reports Server (NTRS)
Harper, Richard E.; Elks, Carl
1995-01-01
An Army Fault Tolerant Architecture (AFTA) has been developed to meet real-time fault tolerant processing requirements of future Army applications. AFTA is the enabling technology that will allow the Army to configure existing processors and other hardware to provide high throughput and ultrahigh reliability necessary for TF/TA/NOE flight control and other advanced Army applications. A comprehensive conceptual study of AFTA has been completed that addresses a wide range of issues including requirements, architecture, hardware, software, testability, producibility, analytical models, validation and verification, common mode faults, VHDL, and a fault tolerant data bus. A Brassboard AFTA for demonstration and validation has been fabricated, and two operating systems and a flight-critical Army application have been ported to it. Detailed performance measurements have been made of fault tolerance and operating system overheads while AFTA was executing the flight application in the presence of faults.
Parkison, Steven A.; Carlson, Jay D.; Chaudoin, Tammy R.; Hoke, Traci A.; Schenk, A. Katrin; Goulding, Evan H.; Pérez, Lance C.; Bonasera, Stephen J.
2016-01-01
Inexpensive, high-throughput, low maintenance systems for precise temporal and spatial measurement of mouse home cage behavior (including movement, feeding, and drinking) are required to evaluate products from large scale pharmaceutical design and genetic lesion programs. These measurements are also required to interpret results from more focused behavioral assays. We describe the design and validation of a highly-scalable, reliable mouse home cage behavioral monitoring system modeled on a previously described, one-of-a-kind system [1]. Mouse position was determined by solving static equilibrium equations describing the force and torques acting on the system strain gauges; feeding events were detected by a photobeam across the food hopper, and drinking events were detected by a capacitive lick sensor. Validation studies show excellent agreement between mouse position and drinking events measured by the system compared with video-based observation – a gold standard in neuroscience. PMID:23366406
Using Reliability to Meet Z540.3's 2 percent Rule
NASA Technical Reports Server (NTRS)
Mimbs, Scott M.
2011-01-01
NASA's Kennedy Space Center (KSC) undertook implementation of ANSI/NCSL Z540.3-2006 in October 2008. Early in the implementation, KSC identified that the largest cost driver of Z540.3 implementation is measurement uncertainty analyses for legacy calibration processes. NASA, like other organizations, has a significant inventory of measuring and test equipment (MTE) that have documented calibration procedures without documented measurement uncertainties. This paper provides background information to support the rationale for using high in-tolerance reliability as evidence of compliance to the 2% probability of false acceptance (PFA) quality metric of ANSI/NCSL Z540.3-2006 allowing use of qualifying legacy processes. NASA is adopting this as policy and is recommending NCSL International consider this as a method of compliance to Z540.3. Topics covered include compliance issues, using end-of-period reliability (EOPR) to estimate test point uncertainty, reliability data influences within the PFA model, the validity of EOPR data, and an appendix covering "observed" versus "true" EOPR.
Reliability of CGA/LGA/HDI Package Board/Assembly (Revision A)
NASA Technical Reports Server (NTRS)
Ghaffarian, Reza
2013-01-01
This follow-up report presents reliability test results conducted by thermal cycling of five CGA assemblies evaluated under two extreme cycle profiles, representative of use for high-reliability applications. The thermal cycles ranged from a low temperature of 55 C to maximum temperatures of either 100 C or 125 C with slow ramp-up rate (3 C/min) and dwell times of about 15 minutes at the two extremes. Optical photomicrographs that illustrate key inspection findings of up to 200 thermal cycles are presented. Other information presented include an evaluation of the integrity of capacitors on CGA substrate after thermal cycling as well as process evaluation for direct assembly of an LGA onto PCB. The qualification guidelines, which are based on the test results for CGA/LGA/HDI packages and board assemblies, will facilitate NASA projects' use of very dense and newly available FPGA area array packages with known reliably and mitigation risks, allowing greater processing power in a smaller board footprint and lower system weight.
Vibration sensibility testing in the workplace. Day-to-day reliability.
Rosecrance, J C; Cook, T M; Satre, D L; Goode, J D; Schroder, M J
1994-09-01
Loss of vibration sensibility has been suggested as an early indicator of peripheral compression neuropathy, including carpal tunnel syndrome. Although vibration sensibility has been used frequently to evaluate carpal tunnel syndrome, the day-to-day reliability of vibration measurements in an industrial population measured at the workplace has not been assessed. Vibration sensibility testing was performed at the university ergonomics laboratory on 50 volunteers (100 hands) and at a newspaper company on 50 workers (100 hands). Vibration perception and disappearance thresholds were measured on two occasions separated by 3 to 5 days. Student's t tests indicated no significant differences between the first and second tests or between the two groups. Pearson product-moment correlations for test-retest reliability were lower in the industry group but were relatively high despite the less than optimal testing conditions. Our findings suggest that vibration sensibility measurements are reliable from day to day not only in the laboratory but also in the workplace.
The Comprehensive Snack Parenting Questionnaire (CSPQ): Development and Test-Retest Reliability.
Gevers, Dorus W M; Kremers, Stef P J; de Vries, Nanne K; van Assema, Patricia
2018-04-26
The narrow focus of existing food parenting instruments led us to develop a food parenting practices instrument measuring the full range of food practices constructs with a focus on snacking behavior. We present the development of the questionnaire and our research on the test-retest reliability. The developed Comprehensive Snack Parenting Questionnaire (CSPQ) covers 21 constructs. Test-retest reliability was assessed by calculating intra class correlation coefficients and percentage agreement after two administrations of the CSPQ among a sample of 66 Dutch parents. Test-retest reliability analysis revealed acceptable intra class correlation coefficients (≥0.41) or agreement scores (≥0.60) for all items. These results, together with earlier work, suggest sufficient psychometric characteristics. The comprehensive, but brief CSPQ opens up chances for highly essential but unstudied research questions to understand and predict children’s snack intake. Example applications include studying the interactional nature of food parenting practices or interactions of food parenting with general parenting or child characteristics.
Krukowski, Rebecca A; Eddings, Kenya; West, Delia Smith
2011-06-01
Restaurant foods represent a substantial portion of children's dietary intake, and consumption of foods away from home has been shown to contribute to excess adiposity. This descriptive study aimed to pilot-test and establish the reliability of a standardized and comprehensive assessment tool, the Children's Menu Assessment, for evaluating the restaurant food environment for children. The tool is an expansion of the Nutrition Environment Measures Survey-Restaurant. In 2009-2010, a randomly selected sample of 130 local and chain restaurants were chosen from within 20 miles of Little Rock, AR, to examine the availability of children's menus and to conduct initial calibration of the Children's Menu Assessment tool (final sample: n=46). Independent raters completed the Children's Menu Assessment in order to determine inter-rater reliability. Test-retest reliability was also examined. Inter-rater reliability was high: percent agreement was 97% and Spearman correlation was 0.90. Test-retest was also high: percent agreement was 91% and Spearman correlation was 0.96. Mean Children's Menu Assessment completion time was 14 minutes, 56 seconds ± 10 minutes, 21 seconds. Analysis of Children's Menu Assessment findings revealed that few healthier options were available on children's menus, and most menus did not provide parents with information for making healthy choices, including nutrition information or identification of healthier options. The Children's Menu Assessment tool allows for comprehensive, rapid measurement of the restaurant food environment for children with high inter-rater reliability. This tool has the potential to contribute to public health efforts to develop and evaluate targeted environmental interventions and/or policy changes regarding restaurant foods. Copyright © 2011 American Dietetic Association. Published by Elsevier Inc. All rights reserved.
Simperingham, Kim D; Cronin, John B; Ross, Angus
2016-11-01
Advanced testing technologies enable insight into the kinematic and kinetic determinants of sprint acceleration performance, which is particularly important for field-based team-sport athletes. Establishing the reliability and validity of the data, particularly from the acceleration phase, is important for determining the utility of the respective technologies. The aim of this systematic review was to explain the utility, reliability, validity and limitations of (1) radar and laser technology, and (2) non-motorised treadmill (NMT) and torque treadmill (TT) technology for providing kinematic and kinetic measures of sprint acceleration performance. A comprehensive search of the CINAHL Plus, MEDLINE (EBSCO), PubMed, SPORTDiscus, and Web of Science databases was conducted using search terms that included radar, laser, non-motorised treadmill, torque treadmill, sprint, acceleration, kinetic, kinematic, force, and power. Studies examining the kinematics or kinetics of short (≤10 s), maximal-effort sprint acceleration in adults or children, which included an assessment of reliability or validity of the advanced technologies of interest, were included in this systematic review. Absolute reliability, relative reliability and validity data were extracted from the selected articles and tabulated. The level of acceptance of reliability was a coefficient of variation (CV) ≤10 % and an intraclass correlation coefficient (ICC) or correlation coefficient (r) ≥0.70. A total of 34 studies met the inclusion criteria and were included in the qualitative analysis. Generally acceptable validity (r = 0.87-0.99; absolute bias 3-7 %), intraday reliability (CV ≤9.5 %; ICC/r ≥0.84) and interday reliability (ICC ≥0.72) were reported for data from radar and laser. However, low intraday reliability was reported for the theoretical maximum horizontal force (ICC 0.64) within adolescent athletes, and low validity was reported for velocity during the initial 5 m of a sprint acceleration (bias up to 0.41 m/s) measured with a laser device. Acceptable reliability of results from NMT and TT was only ensured when testing protocols involved sufficient familiarisation, a high sampling rate (≥200 Hz), a 'blocked' start position, and the analysis of discrete steps rather than arbitrary time periods. Sprinting times and speeds were 20-28 % slower on a TT, 28-67 % slower on an NMT, and only 9-64 % of the variance in overground measurements of speed and time (≤30 m) was explained by results from an NMT. There have been no reports to date of criterion validity of kinetic measures of sprint acceleration performance on NMT andTT, and only limited results regarding acceptable concurrent validity of radar-derived kinetic data. Radar, laser, NMT and TT technologies can be used to reliably measure sprint acceleration performance and to provide insight into the determinants of sprinting speed. However, further research is required to establish the validity of the kinetic measurements made with NMT and TT. Radar and laser technology may not be suitable for measuring the first few steps of a sprint acceleration.
Prediction of Geomagnetic Activity and Key Parameters in High-Latitude Ionosphere-Basic Elements
NASA Technical Reports Server (NTRS)
Lyatsky, W.; Khazanov, G. V.
2007-01-01
Prediction of geomagnetic activity and related events in the Earth's magnetosphere and ionosphere is an important task of the Space Weather program. Prediction reliability is dependent on the prediction method and elements included in the prediction scheme. Two main elements are a suitable geomagnetic activity index and coupling function -- the combination of solar wind parameters providing the best correlation between upstream solar wind data and geomagnetic activity. The appropriate choice of these two elements is imperative for any reliable prediction model. The purpose of this work was to elaborate on these two elements -- the appropriate geomagnetic activity index and the coupling function -- and investigate the opportunity to improve the reliability of the prediction of geomagnetic activity and other events in the Earth's magnetosphere. The new polar magnetic index of geomagnetic activity and the new version of the coupling function lead to a significant increase in the reliability of predicting the geomagnetic activity and some key parameters, such as cross-polar cap voltage and total Joule heating in high-latitude ionosphere, which play a very important role in the development of geomagnetic and other activity in the Earth s magnetosphere, and are widely used as key input parameters in modeling magnetospheric, ionospheric, and thermospheric processes.
Yalın Sapmaz, Şermin; Ergin, Dilek; Şen Celasin, Nesrin; Özek Erkuran, Handan; Karaarslan, Duygu; Öztekin, Siğnem; Uzel Tanrıverdi, Bengisu; Köroğlu, Ertuğrul; Aydemir, Ömer
2017-01-01
The goal of this study was to assess the validity and reliability of the Turkish version of the DSM-5 (Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition) Dissociative Symptoms Severity Scale-Child Form. The scale was prepared by translating and then back-translating the DSM-5 Dissociative Symptoms Severity Scale. The study groups included one group of 30 patients diagnosed with posttraumatic stress disorder who were treated in a child and adolescent psychiatry unit and another group of 83 healthy volunteers from middle and high schools in the community. For assessment, the Adolescent Dissociative Experiences Scale (ADES) was used in addition to the DSM-5 Dissociative Symptoms Severity Scale. Regarding the reliability of the DSM-5 Dissociative Symptoms Severity Scale, Cronbach's alpha was .824 and item-total score correlation coefficients were between .464 and .648. The test-retest correlation coefficient was calculated to be r = .784. In terms of construct validity, one factor accounted for 45.2% of the variance. Furthermore, in terms of concurrent validity, the scale showed a high correlation with the ADES. In conclusion, the Turkish version of the DSM-5 Dissociative Symptoms Severity Scale-Child Form is a valid and reliable tool for both clinical practice and research.
Barreira, Paulo; Robinson, Mark A; Drust, Barry; Nedergaard, Niels; Raja Azidin, Raja Mohammed Firhad; Vanrenterghem, Jos
2017-09-01
The aim of the present study was to examine reliability and construct convergent validity of Player Load™ (PL) from trunk-mounted accelerometry, expressed as a cumulative measure and an intensity measure (PL · min - 1 ). Fifteen male participants twice performed an overground football match simulation that included four different multidirectional football actions (jog, side cut, stride and sprint) whilst wearing a trunk-mounted accelerometer inbuilt in a global positioning system unit. Results showed a moderate-to-high reliability as indicated by the intra-class correlation coefficient (0.806-0.949) and limits of agreement. Convergent validity analysis showed considerable between-participant variation (coefficient of variation range 14.5-24.5%), which was not explained from participant demographics despite a negative association with body height for the stride task. Between-task variations generally showed a moderate correlation between ranking of participants for PL (0.593-0.764) and PL · min - 1 (0.282-0.736). It was concluded that monitoring PL ® in football multidirectional actions presents moderate-to-high reliability, that between-participant variability most likely relies on the individual's locomotive skills and not their anthropometrics, and that the intensity of a task expressed by PL · min - 1 is largely related to the running velocity of the task.
Requirements and approach for a space tourism launch system
NASA Astrophysics Data System (ADS)
Penn, Jay P.; Lindley, Charles A.
2003-01-01
Market surveys suggest that a viable space tourism industry will require flight rates about two orders of magnitude higher than those required for conventional spacelift. Although enabling round-trip cost goals for a viable space tourism business are about 240/pound (529/kg), or 72,000/passenger round-trip, goals should be about 50/pound (110/kg) or approximately 15,000 for a typical passenger and baggage. The lower price will probably open space tourism to the general population. Vehicle reliabilities must approach those of commercial aircraft as closely as possible. This paper addresses the development of spaceplanes optimized for the ultra-high flight rate and high reliability demands of the space tourism mission. It addresses the fundamental operability, reliability, and cost drivers needed to satisfy this mission need. Figures of merit similar to those used to evaluate the economic viability of conventional commercial aircraft are developed, including items such as payload/vehicle dry weight, turnaround time, propellant cost per passenger, and insurance and depreciation costs, which show that infrastructure can be developed for a viable space tourism industry. A reference spaceplane design optimized for space tourism is described. Subsystem allocations for reliability, operability, and costs are made and a route to developing such a capability is discussed. The vehicle's ability to satisfy the traditional spacelift market is also shown.
NASA Astrophysics Data System (ADS)
Abramov, Ivan
2018-03-01
Development of design documentation for a future construction project gives rise to a number of issues with the main one being selection of manpower for structural units of the project's overall implementation system. Well planned and competently staffed integrated structural construction units will help achieve a high level of reliability and labor productivity and avoid negative (extraordinary) situations during the construction period eventually ensuring improved project performance. Research priorities include the development of theoretical recommendations for enhancing reliability of a structural unit staffed as an integrated construction crew. The author focuses on identification of destabilizing factors affecting formation of an integrated construction crew; assessment of these destabilizing factors; based on the developed mathematical model, highlighting the impact of these factors on the integration criterion with subsequent identification of an efficiency and reliability criterion for the structural unit in general. The purpose of this article is to develop theoretical recommendations and scientific and methodological provisions of an organizational and technological nature in order to identify a reliability criterion for a structural unit based on manpower integration and productivity criteria. With this purpose in mind, complex scientific tasks have been defined requiring special research, development of corresponding provisions and recommendations based on the system analysis findings presented herein.
Extended version of the "Sniffin' Sticks" identification test: test-retest reliability and validity.
Sorokowska, A; Albrecht, E; Haehner, A; Hummel, T
2015-03-30
The extended, 32-item version of the Sniffin' Sticks identification test was developed in order to create a precise tool enabling repeated, longitudinal testing of individual olfactory subfunctions. Odors of the previous test version had to be changed for technical reasons, and the odor identification test needed re-investigation in terms of reliability, validity, and normative values. In our study we investigated olfactory abilities of a group of 100 patients with olfactory dysfunction and 100 controls. We reconfirmed the high test-retest reliability of the extended version of the Sniffin' Sticks identification test and high correlations between the new and the original part of this tool. In addition, we confirmed the validity of the test as it discriminated clearly between controls and patients with olfactory loss. The additional set of 16 odor identification sticks can be either included in the current olfactory test, thus creating a more detailed diagnosis tool, or it can be used separately, enabling to follow olfactory function over time. Additionally, the normative values presented in our paper might provide useful guidelines for interpretation of the extended identification test results. The revised version of the Sniffin' Sticks 32-item odor identification test is a reliable and valid tool for the assessment of olfactory function. Copyright © 2015 Elsevier B.V. All rights reserved.
Brett, Benjamin L; Solomon, Gary S; Hill, Jennifer; Schatz, Philip
2018-03-01
This study examined the test-retest reliability of the four- and two-factor structures (i.e., Memory and Speed) of ImPACT over a 2-year interval across multiple groups with premorbid conditions, including those with a history of special education or learning disorders (LD; n = 114), treatment history for headache/migraine (n = 81), and a control group (n = 792). Nine hundred and eighty seven high school athletes completed baseline testing using online ImPACT across a 2-year interval. Paired-samples t-tests documented improvement from initial to follow-up assessments. Test stability was examined using Regression-based measures (RBM) and Reliable change indices (RCI). Reliability was examined using intraclass correlation coefficients (ICC). Significant improvement on all four composites were observed for the control group over a 2-year interval; whereas significant differences were observed only on Visual Motor Speed for the LD and headache/migraine treatment history groups. ICCs ranges were similar across groups and greater or comparable reliability was observed for the two-factor structure on Memory (0.67-0.73) and Speed (0.76-0.78) composites. RCIs and RBMs demonstrated stability for the four- and two-factor structures, with few cases falling outside the range of expected change within a healthy sample at the 90% and 95% CIs. Typical practices of obtaining new baselines every 2 years in the high school population can be applied to athletes with a history of special education or LD and headache/migraine treatment. The two-factor structure has potential to increase test-retest reliability. Further research regarding clinical utility is needed. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
NASA Technical Reports Server (NTRS)
Bast, Callie C.; Jurena, Mark T.; Godines, Cody R.; Chamis, Christos C. (Technical Monitor)
2001-01-01
This project included both research and education objectives. The goal of this project was to advance innovative research and education objectives in theoretical and computational probabilistic structural analysis, reliability, and life prediction for improved reliability and safety of structural components of aerospace and aircraft propulsion systems. Research and education partners included Glenn Research Center (GRC) and Southwest Research Institute (SwRI) along with the University of Texas at San Antonio (UTSA). SwRI enhanced the NESSUS (Numerical Evaluation of Stochastic Structures Under Stress) code and provided consulting support for NESSUS-related activities at UTSA. NASA funding supported three undergraduate students, two graduate students, a summer course instructor and the Principal Investigator. Matching funds from UTSA provided for the purchase of additional equipment for the enhancement of the Advanced Interactive Computational SGI Lab established during the first year of this Partnership Award to conduct the probabilistic finite element summer courses. The research portion of this report presents the cumulation of work performed through the use of the probabilistic finite element program, NESSUS, Numerical Evaluation and Structures Under Stress, and an embedded Material Strength Degradation (MSD) model. Probabilistic structural analysis provided for quantification of uncertainties associated with the design, thus enabling increased system performance and reliability. The structure examined was a Space Shuttle Main Engine (SSME) fuel turbopump blade. The blade material analyzed was Inconel 718, since the MSD model was previously calibrated for this material. Reliability analysis encompassing the effects of high temperature and high cycle fatigue, yielded a reliability value of 0.99978 using a fully correlated random field for the blade thickness. The reliability did not change significantly for a change in distribution type except for a change in distribution from Gaussian to Weibull for the centrifugal load. The sensitivity factors determined to be most dominant were the centrifugal loading and the initial strength of the material. These two sensitivity factors were influenced most by a change in distribution type from Gaussian to Weibull. The education portion of this report describes short-term and long-term educational objectives. Such objectives serve to integrate research and education components of this project resulting in opportunities for ethnic minority students, principally Hispanic. The primary vehicle to facilitate such integration was the teaching of two probabilistic finite element method courses to undergraduate engineering students in the summers of 1998 and 1999.
Space Shuttle Software Development and Certification
NASA Technical Reports Server (NTRS)
Orr, James K.; Henderson, Johnnie A
2000-01-01
Man-rated software, "software which is in control of systems and environments upon which human life is critically dependent," must be highly reliable. The Space Shuttle Primary Avionics Software System is an excellent example of such a software system. Lessons learn from more than 20 years of effort have identified basic elements that must be present to achieve this high degree of reliability. The elements include rigorous application of appropriate software development processes, use of trusted tools to support those processes, quantitative process management, and defect elimination and prevention. This presentation highlights methods used within the Space Shuttle project and raises questions that must be addressed to provide similar success in a cost effective manner on future long-term projects where key application development tools are COTS rather than internally developed custom application development tools
NASA reliability preferred practices for design and test
NASA Technical Reports Server (NTRS)
1991-01-01
Given here is a manual that was produced to communicate within the aerospace community design practices that have contributed to NASA mission success. The information represents the best technical advice that NASA has to offer on reliability design and test practices. Topics covered include reliability practices, including design criteria, test procedures, and analytical techniques that have been applied to previous space flight programs; and reliability guidelines, including techniques currently applied to space flight projects, where sufficient information exists to certify that the technique will contribute to mission success.
Lange, Toni; Freiberg, Alice; Dröge, Patrik; Lützner, Jörg; Schmitt, Jochen; Kopkow, Christian
2015-06-01
Systematic literature review. Despite their frequent application in routine care, a systematic review on the reliability of clinical examination tests to evaluate the integrity of the ACL is missing. To summarize and evaluate intra- and interrater reliability research on physical examination tests used for the diagnosis of ACL tears. A comprehensive systematic literature search was conducted in MEDLINE, EMBASE and AMED until May 30th 2013. Studies were included if they assessed the intra- and/or interrater reliability of physical examination tests for the integrity of the ACL. Methodological quality was evaluated with the Quality Appraisal of Reliability Studies (QAREL) tool by two independent reviewers. 110 hits were achieved of which seven articles finally met the inclusion criteria. These studies examined the reliability of four physical examination tests. Intrarater reliability was assessed in three studies and ranged from fair to almost perfect (Cohen's k = 0.22-1.00). Interrater reliability was assessed in all included studies and ranged from slight to almost perfect (Cohen's k = 0.02-0.81). The Lachman test is the physical tests with the highest intrarater reliability (Cohen's k = 1.00), the Lachman test performed in prone position the test with the highest interrater reliability (Cohen's k = 0.81). Included studies were partly of low methodological quality. A meta-analysis could not be performed due to the heterogeneity in study populations, reliability measures and methodological quality of included studies. Systematic investigations on the reliability of physical examination tests to assess the integrity of the ACL are scarce and of varying methodological quality. Copyright © 2014 Elsevier Ltd. All rights reserved.
Launch and Assembly Reliability Analysis for Mars Human Space Exploration Missions
NASA Technical Reports Server (NTRS)
Cates, Grant R.; Stromgren, Chel; Cirillo, William M.; Goodliff, Kandyce E.
2013-01-01
NASA s long-range goal is focused upon human exploration of Mars. Missions to Mars will require campaigns of multiple launches to assemble Mars Transfer Vehicles in Earth orbit. Launch campaigns are subject to delays, launch vehicles can fail to place their payloads into the required orbit, and spacecraft may fail during the assembly process or while loitering prior to the Trans-Mars Injection (TMI) burn. Additionally, missions to Mars have constrained departure windows lasting approximately sixty days that repeat approximately every two years. Ensuring high reliability of launching and assembling all required elements in time to support the TMI window will be a key enabler to mission success. This paper describes an integrated methodology for analyzing and improving the reliability of the launch and assembly campaign phase. A discrete event simulation involves several pertinent risk factors including, but not limited to: manufacturing completion; transportation; ground processing; launch countdown; ascent; rendezvous and docking, assembly, and orbital operations leading up to TMI. The model accommodates varying numbers of launches, including the potential for spare launches. Having a spare launch capability provides significant improvement to mission success.
CSTI high capacity power. [Civil Space Technology Initiative
NASA Technical Reports Server (NTRS)
Winter, Jerry M.
1989-01-01
In FY-88, the Advanced Technology Program was incorporated into NASA's Civil Space Technology Initiative (CSTI). The CSTI Program was established to provide the foundation for technology development in automation and robotics, information, propulsion, and power. The CSTI High Capacity Power Program builds on the technology efforts of the SP-100 program, incorporates the previous NASA SP-100 Advanced Technology project, and provides a bridge to NASA Project Pathfinder. The elements of CSTI High Capacity Power development include Converrsion Systems, Thermal Management, Power Management, System Diagnostics, and Environmental Interactions. Technology advancement in all areas, including materials, is required to assure the high reliability and 7 to 10 year lifetime demanded for future space nuclear power systems.
Madsen, Pernille H; Bak, Klaus; Jensen, Susanne; Welter, Ulrik
2011-03-01
Scapular dyskinesis is a major etiological factor in overhead athletes' shoulder problems. Our hypotheses were to evaluate if (1) visual observation of scapular dyskinesis during scaption has substantial interobserver reliability, and (2) scapular dyskinesis may be induced by swim training in pain-free swimmers. A reliability and observational study. Bachelor project at a college institution and at a private sports orthopedic hospital. Seventy-eight competitive swimmers with no history of shoulder pain were included in the study. Fourteen swimmers were evaluated regarding reliability. Inclusion criteria were competitive swimmers with high training volume who previously had no shoulder pain. Observations of scapular dyskinesis (yes/no) during simple scaption. The interobserver reliability of scaption and wall push-up was evaluated in 14 swimmers using kappa analysis. Prevalence of scapular dyskinesis at 4 time intervals during a swim training session. The scaption test resulted in a weighted kappa value of 0.75. Scapular dyskinesis was seen in 29 shoulders (37%) after the first time interval, in another 24 (cumulated prevalence 68%) after one-half of the training session, and in an additional 4 swimmers (cumulated prevalence 73%) after three-quarters of the training session. During the last quarter of the training session, another 7 swimmers had dyskinesis, resulting in a cumulated prevalence of 82%. The prevalence of abnormal scapular kinesis during a normal training session is high in previously pain-free swimmers. The prevalence increases with more training and occurs early during the training session.
Alonso, Ariel; Laenen, Annouschka
2013-05-01
Laenen, Alonso, and Molenberghs (2007) and Laenen, Alonso, Molenberghs, and Vangeneugden (2009) proposed a method to assess the reliability of rating scales in a longitudinal context. The methodology is based on hierarchical linear models, and reliability coefficients are derived from the corresponding covariance matrices. However, finding a good parsimonious model to describe complex longitudinal data is a challenging task. Frequently, several models fit the data equally well, raising the problem of model selection uncertainty. When model uncertainty is high one may resort to model averaging, where inferences are based not on one but on an entire set of models. We explored the use of different model building strategies, including model averaging, in reliability estimation. We found that the approach introduced by Laenen et al. (2007, 2009) combined with some of these strategies may yield meaningful results in the presence of high model selection uncertainty and when all models are misspecified, in so far as some of them manage to capture the most salient features of the data. Nonetheless, when all models omit prominent regularities in the data, misleading results may be obtained. The main ideas are further illustrated on a case study in which the reliability of the Hamilton Anxiety Rating Scale is estimated. Importantly, the ambit of model selection uncertainty and model averaging transcends the specific setting studied in the paper and may be of interest in other areas of psychometrics. © 2012 The British Psychological Society.
Moro, Maria Francesca; Colom, Francesc; Floris, Francesca; Pintus, Elisa; Pintus, Mirra; Contini, Francesca; Carta, Mauro Giovanni
2012-01-01
Background: Functioning Assessment Short Test (FAST) is a brief instrument designed to assess the main functioning problems experienced by psychiatric patients, specifically bipolar patients. It includes 24 items assessing impairment or disability in six domains of functioning: autonomy, occupational functioning, cognitive functioning, financial issues, interpersonal relationships and leisure time. The aim of this study is to measure the validity and reliability of the Italian version of this instrument. Methods: Twenty-four patients with DSM-IV TR bipolar disorder and 20 healthy controls were recruited and evaluated in three private clinics in Cagliari (Sardinia, Italy). The psychometric properties of FAST (feasibility, internal consistency, concurrent validity, discriminant validity (patients vs controls and eutimic patients vs manic and depressed), and test-retest reliability were analyzed. Results: The internal consistency obtained was very high with a Cronbach's alpha of 0.955. A highly significant negative correlation with GAF was obtained (r = -0.9; p < 0.001) pointing to a reasonable degree of concurrent validity. FAST show a good test-retest reliability between two independent evaluation differing of one week (mean K =0.73). The total FAST scores were lower in controls as compared with Bipolar Patients and in Euthimic patients compared with Depressed or Manic. Conclusion: The Italian version of the FAST showed similar psychometrics properties as far as regard internal consistency and discriminant validity of the original version and show a good test retest reliability measure by means of K statistics. PMID:22905035
Parsons, Jeffrey T; Rendina, H Jonathon; Ventuneac, Ana; Cook, Karon F; Grov, Christian; Mustanski, Brian
2013-12-01
The Hypersexual Disorder Screening Inventory (HDSI) was designed as an instrument for the screening of hypersexuality by the American Psychiatric Association's taskforce for the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders. Our study sought to conduct a psychometric analysis of the HDSI, including an investigation of its underlying structure and reliability utilizing item response theory (IRT) modeling, and an examination of its polythetic scoring criteria in comparison to a standard dimensionally based cutoff score. We examined a diverse group of 202 highly sexually active gay and bisexual men in New York City. We conducted psychometric analyses of the HDSI, including both confirmatory factor analysis of its structure and IRT analysis of the item and scale reliabilities. We utilized the HDSI. The HDSI adequately fit a single-factor solution, although there was evidence that two of the items may measure a second factor that taps into sex as a form of coping. The scale showed evidence of strong reliability across much of the continuum of hypersexuality, and results suggested that, in addition to the proposed polythetic scoring criteria, a cutoff score of 20 on the severity index might be used for preliminary classification of HD. The HDSI was found to be highly reliable, and results suggested that a unidimensional, quantitative conception of hypersexuality with a clinically relevant cutoff score may be more appropriate than a qualitative syndrome comprised of multiple distinct clusters of problems. However, we also found preliminary evidence that three clusters of symptoms may constitute an HD syndrome as opposed to the two clusters initially proposed. Future research is needed to determine which of these issues are characteristic of the hypersexuality and HD constructs themselves and which are more likely to be methodological artifacts of the HDSI. © 2013 International Society for Sexual Medicine.
Design of space-type electronic power transformers
NASA Technical Reports Server (NTRS)
Ahearn, J. F.; Lagadinos, J. C.
1977-01-01
Both open and encapsulated varieties of high reliability, low weight, and high efficiency moderate and high voltage transformers were investigated to determine the advantages and limitations of their construction in the ranges of power and voltage required for operation in the hard vacuum environment of space. Topics covered include: (1) selection of the core material; (2) preliminary calculation of core dimensions; (3) selection of insulating materials including magnet wire insulation, coil forms, and layer and interwinding insulation; (4) coil design; (5) calculation of copper losses, core losses and efficiency; (6) calculation of temperature rise; and (7) optimization of design with changes in core selection or coil design as required to meet specifications.
Beliefs about the Consequences of Maternal Employment for Children.
ERIC Educational Resources Information Center
Greenberger, Ellen; And Others
1988-01-01
Developed a 24-item scale to measure Beliefs about the Consequences of Maternal Employment for Children, including beliefs about both benefits and costs. Demonstrated reliability and high convergent, divergent, and concurrent validity. Assessed sex-role traditionalism, women's employment status, work hours, age of child at which employment is…
A Swedish cross-cultural adaptation and validation of the Tinnitus Functional Index.
Hoff, Maria; Kähäri, Kim
2017-04-01
The Tinnitus Functional Index (TFI) is a recent self-report instrument for tinnitus with potential advantages over other existing instruments, including a demonstrated high responsiveness. The objectives of this study were to translate and cross-culturally adapt the TFI into Swedish and to investigate its validity and reliability. The development of the Swedish version (TFI-SE) followed published guidelines on cross-cultural adaptation of health questionnaires. Validity and reliability was investigated by correlating responses on the TFI-SE with other tinnitus measures [Tinnitus Handicap Inventory (THI) and visual analogue scale (VAS)] and a scale measuring anxiety and depression (HADS). Consecutively recruited tinnitus patients (n = 100) from four Swedish clinics completed the questionnaires. The mean age of the sample was 51 years (SD =17). The internal consistency of the TFI-SE was good (α = 0.95) and the test-retest reliability was high (ICC =0.93). Our results supported the eight-factor structure proposed for the original TFI, and a high correlation between the TFI-SE and the THI (r = 0.8; p < 0.01) and lower correlations between the TFI-SE and the HADS-D (r = 0.60; p < 0.01) and HADS-A (r = 0.59; p < 0.01) confirmed satisfactory convergent and discriminant validity. We found that the Swedish translation and cross-cultural adaptation of the TFI is valid and reliable for use with adult tinnitus patients.
Aldous, Jeffrey W F; Akubat, Ibrahim; Chrismas, Bryna C R; Watkins, Samuel L; Mauger, Alexis R; Midgley, Adrian W; Abt, Grant; Taylor, Lee
2014-07-01
This study investigated the reliability and validity of a novel nonmotorised treadmill (NMT)-based soccer simulation using a novel activity category called a "variable run" to quantify fatigue during high-speed running. Twelve male University soccer players completed 3 familiarization sessions and 1 peak speed assessment before completing the intermittent soccer performance test (iSPT) twice. The 2 iSPTs were separated by 6-10 days. The total distance, sprint distance, and high-speed running distance (HSD) were 8,968 ± 430 m, 980 ± 75 m and 2,122 ± 140 m, respectively. No significant difference (p > 0.05) was found between repeated trials of the iSPT for all physiological and performance variables. Reliability measures between iSPT1 and iSPT2 showed good agreement (coefficient of variation: <4.6%; intraclass correlation coefficient: >0.80). Furthermore, the variable run phase showed HSD significantly decreased (p ≤ 0.05) in the last 15 minutes (89 ± 6 m) compared with the first 15 minutes (85 ± 7 m), quantifying decrements in high-speed exercise compared with the previous literature. This study validates the iSPT as a NMT-based soccer simulation compared with the previous match-play data and is a reliable tool for assessing and monitoring physiological and performance variables in soccer players. The iSPT could be used in a number of ways including player rehabilitation, understanding the efficacy of nutritional interventions, and also the quantification of environmentally mediated decrements on soccer-specific performance.
Santelmann, Hanno; Franklin, Jeremy; Bußhoff, Jana; Baethge, Christopher
2016-10-01
Schizoaffective disorder is a common diagnosis in clinical practice but its nosological status has been subject to debate ever since it was conceptualized. Although it is key that diagnostic reliability is sufficient, schizoaffective disorder has been reported to have low interrater reliability. Evidence based on systematic review and meta-analysis methods, however, is lacking. Using a highly sensitive literature search in Medline, Embase, and PsycInfo we identified studies measuring the interrater reliability of schizoaffective disorder in comparison to schizophrenia, bipolar disorder, and unipolar disorder. Out of 4126 records screened we included 25 studies reporting on 7912 patients diagnosed by different raters. The interrater reliability of schizoaffective disorder was moderate (meta-analytic estimate of Cohen's kappa 0.57 [95% CI: 0.41-0.73]), and substantially lower than that of its main differential diagnoses (difference in kappa between 0.22 and 0.19). Although there was considerable heterogeneity, analyses revealed that the interrater reliability of schizoaffective disorder was consistently lower in the overwhelming majority of studies. The results remained robust in subgroup and sensitivity analyses (e.g., diagnostic manual used) as well as in meta-regressions (e.g., publication year) and analyses of publication bias. Clinically, the results highlight the particular importance of diagnostic re-evaluation in patients diagnosed with schizoaffective disorder. They also quantify a widely held clinical impression of lower interrater reliability and agree with earlier meta-analysis reporting low test-retest reliability. Copyright © 2016. Published by Elsevier B.V.
Arunakul, Marut; Arunakul, Preeyaphan; Suesiritumrong, Chakhrist; Angthong, Chayanin; Chernchujit, Bancha
2015-06-01
Self-administered questionnaires have become an important aspect for clinical outcome assessment of foot and ankle-related problems. The Foot and Ankle Ability Measure (FAAM) subjective form is a region-specific questionnaire that is widely used and has sufficient validity and reliability from previous studies. Translate the original English version of FAAM into a Thai version and evaluate the validity and reliability of Thai FAAM in patients with foot and ankle-related problems. The FAAM subjective form was translated into Thai using forward-backward translation protocol. Afterward, reliability and validity were tested. Following responses from 60 consecutive patients on two questionnaires, the Thai FAAM subjective form and the short form (SF)-36, were used. The validity was tested by correlating the scores from both questionnaires. The reliability was adopted by measuring the test-retest reliability and internal consistency. Thai FAAM score including activity of daily life (ADL) and Sport subscale demonstrated the sufficient correlations with physical functioning (PF) and physical composite score (PCS) domains of the SF-36 (statistically significant with p < 0.001 level and ≥ 0.5 values). The result of reliability revealed highly intra-class correlation coefficient as 0.8 and 0.77, respectively from test-retest study. The internal consistency was strong (Cronbach alpha = 0.94 and 0.88, respectively). The Thai version of FAAM subjective form retained the characteristics of the original version and has proved a reliable evaluation instrument for patients with foot and ankle-related problems.
Proceedings of the 26th Project Integration Meeting
NASA Technical Reports Server (NTRS)
1986-01-01
Progress made by the Flat-plate Solar Array (FSA) Project is described for the period July 1985 to April 1986. Included are reports on silicon sheet growth and characterization, silicon material, process development, high-efficienty cells, environmental isolation, engineering sciences, and reliability physics. Also included are technical and plenary presentations made at the 26th Project Integration Meeting (PIM) held on April 29 to 30 and May 1, 1986.
Cross-cultural Adaption and Validation of the Danish Voice Handicap Index.
Sorensen, Jesper Roed; Printz, Trine; Mehlum, Camilla Slot; Heidemann, Christian Hamilton; Groentved, Aagot Moeller; Godballe, Christian
2018-02-02
We aimed to assess psychometric properties, including internal consistency, reliability, and clinical validity of the Danish version of the Voice Handicap Index (VHI). A cross-sectional survey study was carried out. For validation, the existing nonvalidated Danish version of the VHI was used. Data from 208 patients with voice disorders of different etiology (neurogenic, functional, and structural) and a control group of 85 vocally healthy individuals were included. A test-retest reliability analysis of 42 patients and 45 control persons was performed. The internal consistency, test-retest reliability, and clinical validity of the questionnaire were assessed. Internal consistency was high with a Cronbach α >0.90 for both the patient and control group. Test-retest reliability measured as intraclass correlation coefficient was good with 0.93 (95% confidence interval [95% confidence interval]: 0.87-0.96) for patients and 0.78 (95% confidence interval: 0.63-0.87) for the control group which indicates sufficient reliability of the questionnaire. The Danish VHI has good clinical validity as it has a strong correlation between patient's perception of the severity of their voice disorder and the VHI score from the Spearman correlation of 0.69. The existing Danish version of the VHI has been thoroughly validated and found to be in line with the original VHI from Jacobsen et al. It showed good internal consistency, test-retest reliability, and clinical validity. It is suitable for use in daily practice and in research projects as it is able to assess patients' perception of their voice disorder severity. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Perez, Concepcion; Galvez, Rafael; Huelbes, Silvia; Insausti, Joaquin; Bouhassira, Didier; Diaz, Silvia; Rejas, Javier
2007-01-01
Background This study assesses the validity and reliability of the Spanish version of DN4 questionnaire as a tool for differential diagnosis of pain syndromes associated to a neuropathic (NP) or somatic component (non-neuropathic pain, NNP). Methods A study was conducted consisting of two phases: cultural adaptation into the Spanish language by means of conceptual equivalence, including forward and backward translations in duplicate and cognitive debriefing, and testing of psychometric properties in patients with NP (peripheral, central and mixed) and NNP. The analysis of psychometric properties included reliability (internal consistency, inter-rater agreement and test-retest reliability) and validity (ROC curve analysis, agreement with the reference diagnosis and determination of sensitivity, specificity, and positive and negative predictive values in different subsamples according to type of NP). Results A sample of 164 subjects (99 women, 60.4%; age: 60.4 ± 16.0 years), 94 (57.3%) with NP (36 with peripheral, 32 with central, and 26 with mixed pain) and 70 with NNP was enrolled. The questionnaire was reliable [Cronbach's alpha coefficient: 0.71, inter-rater agreement coefficient: 0.80 (0.71–0.89), and test-retest intra-class correlation coefficient: 0.95 (0.92–0.97)] and valid for a cut-off value ≥ 4 points, which was the best value to discriminate between NP and NNP subjects. Discussion This study, representing the first validation of the DN4 questionnaire into another language different than the original, not only supported its high discriminatory value for identification of neuropathic pain, but also provided supplemental psychometric validation (i.e. test-retest reliability, influence of educational level and pain intensity) and showed its validity in mixed pain syndromes. PMID:18053212
Reliability of a Qualitative Video Analysis for Running.
Pipkin, Andrew; Kotecki, Kristy; Hetzel, Scott; Heiderscheit, Bryan
2016-07-01
Study Design Reliability study. Background Video analysis of running gait is frequently performed in orthopaedic and sports medicine practices to assess biomechanical factors that may contribute to injury. However, the reliability of a whole-body assessment has not been determined. Objective To determine the intrarater and interrater reliability of the qualitative assessment of specific running kinematics from a 2-dimensional video. Methods Running-gait analysis was performed on videos recorded from 15 individuals (8 male, 7 female) running at a self-selected pace (3.17 ± 0.40 m/s, 8:28 ± 1:04 min/mi) using a high-speed camera (120 frames per second). These videos were independently rated on 2 occasions by 3 experienced physical therapists using a standardized qualitative assessment. Fifteen sagittal and frontal plane kinematic variables were rated on a 3- or 5-point categorical scale at specific events of the gait cycle, including initial contact (n = 3) and midstance (n = 9), or across the full gait cycle (n = 3). The video frame number corresponding to each gait event was also recorded. Intrarater and interrater reliability values were calculated for gait-event detection (intraclass correlation coefficient [ICC] and standard error of measurement [SEM]) and the individual kinematic variables (weighted kappa [κw]). Results Gait-event detection was highly reproducible within raters (ICC = 0.94-1.00; SEM, 0.3-1.0 frames) and between raters (ICC = 0.77-1.00; SEM, 0.4-1.9 frames). Eleven of the 15 kinematic variables demonstrated substantial (κw = 0.60-0.799) or excellent (κw>0.80) intrarater agreement, with the exception of foot-to-center-of-mass position (κw = 0.59), forefoot position (κw = 0.58), ankle dorsiflexion at midstance (κw = 0.49), and center-of-mass vertical excursion (κw = 0.36). Interrater agreement for the kinematic measures varied more widely (κw = 0.00-0.85), with 5 variables showing substantial or excellent reliability. Conclusion The qualitative assessment of specific kinematic measures during running can be reliably performed with the use of a high-speed video camera. Detection of specific gait events was highly reproducible, as were common kinematic variables such as rearfoot position, foot-strike pattern, tibial inclination angle, knee flexion angle, and forward trunk lean. Other variables should be used with caution. J Orthop Sports Phys Ther 2016;46(7):556-561. Epub 6 Jun 2016. doi:10.2519/jospt.2016.6280.
Eliasson, Kristina; Palm, Peter; Nyman, Teresia; Forsman, Mikael
2017-07-01
A common way to conduct practical risk assessments is to observe a job and report the observed long term risks for musculoskeletal disorders. The aim of this study was to evaluate the inter- and intra-observer reliability of ergonomists' risk assessments without the support of an explicit risk assessment method. Twenty-one experienced ergonomists assessed the risk level (low, moderate, high risk) of eight upper body regions, as well as the global risk of 10 video recorded work tasks. Intra-observer reliability was assessed by having nine of the ergonomists repeat the procedure at least three weeks after the first assessment. The ergonomists made their risk assessment based on his/her experience and knowledge. The statistical parameters of reliability included agreement in %, kappa, linearly weighted kappa, intraclass correlation and Kendall's coefficient of concordance. The average inter-observer agreement of the global risk was 53% and the corresponding weighted kappa (K w ) was 0.32, indicating fair reliability. The intra-observer agreement was 61% and 0.41 (K w ). This study indicates that risk assessments of the upper body, without the use of an explicit observational method, have non-acceptable reliability. It is therefore recommended to use systematic risk assessment methods to a higher degree. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Lange, Toni; Struyf, Filip; Schmitt, Jochen; Lützner, Jörg; Kopkow, Christian
2017-07-01
Systematic review. The aim of this systematic review was to summarize and evaluate intra- and interrater reliability research of physical examination tests used for the assessment of scapular dyskinesis. Scapular dyskinesis, defined as alteration of normal scapular kinematics, is described as a non-specific response to different shoulder pathologies. A systematic literature search was conducted in MEDLINE, EMBASE, AMED and PEDro until March 20th, 2015. Methodological quality was assessed with the Quality Appraisal of Reliability Studies (QAREL) by two independent reviewers. The search strategy revealed 3259 articles, of which 15 met the inclusion criteria. These studies evaluated the reliability of 41 test and test variations used for the assessment of scapular dyskinesis. This review identified a lack of high-quality studies evaluating intra- as well as interrater reliability of tests used for the assessment of scapular dyskinesis. In addition, reliability measures differed between included studies hindering proper cross-study comparisons. The effect of manual correction of the scapula on shoulder symptoms was evaluated in only one study, which is striking, since symptom alteration tests are used in routine care to guide further treatment. Thus, there is a strong need for further research in this area. Diagnosis, level 3a. Copyright © 2016. Published by Elsevier Ltd.
TIMESERIESSTREAMING.VI: LabVIEW program for reliable data streaming of large analog time series
NASA Astrophysics Data System (ADS)
Czerwinski, Fabian; Oddershede, Lene B.
2011-02-01
With modern data acquisition devices that work fast and very precise, scientists often face the task of dealing with huge amounts of data. These need to be rapidly processed and stored onto a hard disk. We present a LabVIEW program which reliably streams analog time series of MHz sampling. Its run time has virtually no limitation. We explicitly show how to use the program to extract time series from two experiments: For a photodiode detection system that tracks the position of an optically trapped particle and for a measurement of ionic current through a glass capillary. The program is easy to use and versatile as the input can be any type of analog signal. Also, the data streaming software is simple, highly reliable, and can be easily customized to include, e.g., real-time power spectral analysis and Allan variance noise quantification. Program summaryProgram title: TimeSeriesStreaming.VI Catalogue identifier: AEHT_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEHT_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 250 No. of bytes in distributed program, including test data, etc.: 63 259 Distribution format: tar.gz Programming language: LabVIEW ( http://www.ni.com/labview/) Computer: Any machine running LabVIEW 8.6 or higher Operating system: Windows XP and Windows 7 RAM: 60-360 Mbyte Classification: 3 Nature of problem: For numerous scientific and engineering applications, it is highly desirable to have an efficient, reliable, and flexible program to perform data streaming of time series sampled with high frequencies and possibly for long time intervals. This type of data acquisition often produces very large amounts of data not easily streamed onto a computer hard disk using standard methods. Solution method: This LabVIEW program is developed to directly stream any kind of time series onto a hard disk. Due to optimized timing and usage of computational resources, such as multicores and protocols for memory usage, this program provides extremely reliable data acquisition. In particular, the program is optimized to deal with large amounts of data, e.g., taken with high sampling frequencies and over long time intervals. The program can be easily customized for time series analyses. Restrictions: Only tested in Windows-operating LabVIEW environments, must use TDMS format, acquisition cards must be LabVIEW compatible, driver DAQmx installed. Running time: As desirable: microseconds to hours
Lindsley, Kristina; Li, Tianjing; Ssemanda, Elizabeth; Virgili, Gianni; Dickersin, Kay
2016-04-01
Are existing systematic reviews of interventions for age-related macular degeneration incorporated into clinical practice guidelines? High-quality systematic reviews should be used to underpin evidence-based clinical practice guidelines and clinical care. We examined the reliability of systematic reviews of interventions for age-related macular degeneration (AMD) and described the main findings of reliable reviews in relation to clinical practice guidelines. Eligible publications were systematic reviews of the effectiveness of treatment interventions for AMD. We searched a database of systematic reviews in eyes and vision without language or date restrictions; the database was up to date as of May 6, 2014. Two authors independently screened records for eligibility and abstracted and assessed the characteristics and methods of each review. We classified reviews as reliable when they reported eligibility criteria, comprehensive searches, methodologic quality of included studies, appropriate statistical methods for meta-analysis, and conclusions based on results. We mapped treatment recommendations from the American Academy of Ophthalmology (AAO) Preferred Practice Patterns (PPPs) for AMD to systematic reviews and citations of reliable systematic reviews to support each treatment recommendation. Of 1570 systematic reviews in our database, 47 met inclusion criteria; most targeted neovascular AMD and investigated anti-vascular endothelial growth factor (VEGF) interventions, dietary supplements, or photodynamic therapy. We classified 33 (70%) reviews as reliable. The quality of reporting varied, with criteria for reliable reporting met more often by Cochrane reviews and reviews whose authors disclosed conflicts of interest. Anti-VEGF agents and photodynamic therapy were the only interventions identified as effective by reliable reviews. Of 35 treatment recommendations extracted from the PPPs, 15 could have been supported with reliable systematic reviews; however, only 1 recommendation cited a reliable intervention systematic review. No reliable systematic review was identified for 20 treatment recommendations, highlighting areas of evidence gaps. For AMD, reliable systematic reviews exist for many treatment recommendations in the AAO PPPs and should be cited to support these recommendations. We also identified areas where no high-level evidence exists. Mapping clinical practice guidelines to existing systematic reviews is one way to highlight areas where evidence generation or evidence synthesis is either available or needed. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
A reliability analysis of the revised competitiveness index.
Harris, Paul B; Houston, John M
2010-06-01
This study examined the reliability of the Revised Competitiveness Index by investigating the test-retest reliability, interitem reliability, and factor structure of the measure based on a sample of 280 undergraduates (200 women, 80 men) ranging in age from 18 to 28 years (M = 20.1, SD = 2.1). The findings indicate that the Revised Competitiveness Index has high test-retest reliability, high inter-item reliability, and a stable factor structure. The results support the assertion that the Revised Competitiveness Index assesses competitiveness as a stable trait rather than a dynamic state.
The Shutdown Dissociation Scale (Shut-D)
Schalinski, Inga; Schauer, Maggie; Elbert, Thomas
2015-01-01
The evolutionary model of the defense cascade by Schauer and Elbert (2010) provides a theoretical frame for a short interview to assess problems underlying and leading to the dissociative subtype of posttraumatic stress disorder. Based on known characteristics of the defense stages “fright,” “flag,” and “faint,” we designed a structured interview to assess the vulnerability for the respective types of dissociation. Most of the scales that assess dissociative phenomena are designed as self-report questionnaires. Their items are usually selected based on more heuristic considerations rather than a theoretical model and thus include anything from minor dissociative experiences to major pathological dissociation. The shutdown dissociation scale (Shut-D) was applied in several studies in patients with a history of multiple traumatic events and different disorders that have been shown previously to be prone to symptoms of dissociation. The goal of the present investigation was to obtain psychometric characteristics of the Shut-D (including factor structure, internal consistency, retest reliability, predictive, convergent and criterion-related concurrent validity). A total population of 225 patients and 68 healthy controls were accessed. Shut-D appears to have sufficient internal reliability, excellent retest reliability, high convergent validity, and satisfactory predictive validity, while the summed score of the scale reliably separates patients with exposure to trauma (in different diagnostic groups) from healthy controls. The Shut-D is a brief structured interview for assessing the vulnerability to dissociate as a consequence of exposure to traumatic stressors. The scale demonstrates high-quality psychometric properties and may be useful for researchers and clinicians in assessing shutdown dissociation as well as in predicting the risk of dissociative responding. PMID:25976478
Chakraborty, Nirali M; Fry, Kenzo; Behl, Rasika; Longfield, Kim
2016-01-01
ABSTRACT Background: Social franchising programs in low- and middle-income countries have tried using the standard wealth index, based on the Demographic and Health Survey (DHS) questionnaire, in client exit interviews to assess clients’ relative wealth compared with the national wealth distribution to ensure equity in service delivery. The large number of survey questions required to capture the wealth index variables have proved cumbersome for programs. Methods: Using an adaptation of the Delphi method, we developed shortened wealth indices and in February 2015 consulted 15 stakeholders in equity measurement. Together, we selected the best of 5 alternative indices, accompanied by 2 measures of agreement (percent agreement and Cohen’s kappa statistic) comparing wealth quintile assignment in the new indices to the full DHS index. The panel agreed that reducing the number of assets was more important than standardization across countries because a short index would provide strong indication of client wealth and be easier to collect and use in the field. Additionally, the panel agreed that the simplified index should be highly correlated with the DHS for each country (kappa ≥ 0.75) for both national and urban-specific samples. We then revised indices for 16 countries and selected the minimum number of questions and question options required to achieve a kappa statistic ≥ 0.75 for both national and urban populations. Findings: After combining the 5 wealth quintiles into 3 groups, which the expert panel deemed more programmatically meaningful, reliability between the standard DHS wealth index and each of 3 simplified indices was high (median kappa = 0.81, 086, and 0.77, respectively, for index B that included only the common questions from the DHS VI questionnaire, index D that included the common questions plus country-specific questions, and index E that found the shortest list of common and country-specific questions that met the minimum reliability criteria of kappa ≥ 0.75). Index E was the simplified index of choice because it was reliable in national and urban contexts while requiring the fewest number of survey questions—6 to 18 per country compared with 25 to 47 in the original DHS wealth index (a 66% average reduction). Conclusion: Social franchise clinics and other types of service delivery programs that want to assess client wealth in relation to a national or urban population can do so with high reliability using a short questionnaire. Future uses of the simplified asset questionnaire include a mobile application for rapid data collection and analysis. PMID:27016550
Chakraborty, Nirali M; Fry, Kenzo; Behl, Rasika; Longfield, Kim
2016-03-01
Social franchising programs in low- and middle-income countries have tried using the standard wealth index, based on the Demographic and Health Survey (DHS) questionnaire, in client exit interviews to assess clients' relative wealth compared with the national wealth distribution to ensure equity in service delivery. The large number of survey questions required to capture the wealth index variables have proved cumbersome for programs. Using an adaptation of the Delphi method, we developed shortened wealth indices and in February 2015 consulted 15 stakeholders in equity measurement. Together, we selected the best of 5 alternative indices, accompanied by 2 measures of agreement (percent agreement and Cohen's kappa statistic) comparing wealth quintile assignment in the new indices to the full DHS index. The panel agreed that reducing the number of assets was more important than standardization across countries because a short index would provide strong indication of client wealth and be easier to collect and use in the field. Additionally, the panel agreed that the simplified index should be highly correlated with the DHS for each country (kappa ≥ 0.75) for both national and urban-specific samples. We then revised indices for 16 countries and selected the minimum number of questions and question options required to achieve a kappa statistic ≥ 0.75 for both national and urban populations. After combining the 5 wealth quintiles into 3 groups, which the expert panel deemed more programmatically meaningful, reliability between the standard DHS wealth index and each of 3 simplified indices was high (median kappa = 0.81, 086, and 0.77, respectively, for index B that included only the common questions from the DHS VI questionnaire, index D that included the common questions plus country-specific questions, and index E that found the shortest list of common and country-specific questions that met the minimum reliability criteria of kappa ≥ 0.75). Index E was the simplified index of choice because it was reliable in national and urban contexts while requiring the fewest number of survey questions-6 to 18 per country compared with 25 to 47 in the original DHS wealth index (a 66% average reduction). Social franchise clinics and other types of service delivery programs that want to assess client wealth in relation to a national or urban population can do so with high reliability using a short questionnaire. Future uses of the simplified asset questionnaire include a mobile application for rapid data collection and analysis. © Chakraborty et al.
Kaufman, Denise R; Puckett, Mallory J; Smith, Mitchell J; Wilson, Kyle S; Cheema, Rebecca; Landers, Merrill R
2014-08-01
The purpose of this study was to establish reliability and responsiveness of the dynamic visual acuity test (DVAT) at head speeds of 150-200 degrees per second (deg/s) and the gaze stabilization test (GST) in high school and college football players. Reliability design. Fifty high school and college football athletes completed the DVAT and GST in both the yaw (horizontal) and pitch (vertical) planes twice within two weeks. Test-retest reliability for the DVAT was good in yaw, Intraclass Correlation Coefficient (ICC) = 0.770, and moderate/good in pitch, ICC = 0.725. Minimal detectable change (MDC) was 0.16 logMAR for yaw and 0.21 logMAR for pitch. GST reliability was moderate in yaw, ICC = 0.634, and poor in pitch, ICC = 0.411. MDCs were 73.4 deg/s (yaw) and 81.2 deg/s (pitch). The DVAT is reliable at high head speeds in high school and college football athletes in both yaw and pitch. GST head speeds were higher than previously reported in the literature, but reliability of this tool for this population was poor to moderate. From a clinical perspective, DVAT may be reliably used in the assessment of high school and college football athletes; however, GST requires further evaluation. Copyright © 2013 Elsevier Ltd. All rights reserved.
Mak, Kwok-Kei; Nam, JeeEun Karin; Kim, Dongil; Aum, Narae; Choi, Jung-Seok; Cheng, Cecilia; Ko, Huei-Chen; Watanabe, Hiroko
2017-03-01
The Korean Scale for Internet Addiction (K-Scale) was developed in Korea for assessing addictive internet behaviors. This study aims to adopt K-Scale and examine its psychometric properties in Japanese adolescents. In 2014, 589 (36.0% boys) high school students (Grade 10-12) from Japan completed a survey, including items of Japanese versions of K-Scale and Smartphone Scale for Smartphone Addiction (S-Scale). Model fit indices of the original four-factor structure, three-factor structure obtained from exploratory factor analysis, and improved two-factor structure of K-Scale were computed using confirmatory factor analysis, with internal reliability of included items reported. The convergent validity of K-Scale was tested against self-rated internet addiction, and S-Scale using multiple regression models. The results showed that a second-order two-factor 13-item structure was the most parsimonious model (NFI=0.919, NNFI=0.935, CFI=0.949, and RMSEA=0.05) with good internal reliability (Cronbach's alpha=0.87). The two factors revealed were "Disturbance of Adaptation and Life Orientation" and "Withdrawal and Tolerance". Moreover, the correlation between internet user classifications defined by K-Scale and self-rating was significant. K-Scale total score was significantly and positively associated with S-Scale total (adjusted R 2 =0.440) and subscale scores (adjusted R 2 =0.439). In conclusion, K-Scale is a valid and reliable assessment scale of internet addiction for Japanese high school students after modifications. Copyright © 2017. Published by Elsevier B.V.
Hong, Jae Young; Modi, Hitesh N.; Hur, Chang Yong; Song, Hae Ryong; Park, Jong Hoon
2010-01-01
Several methods are used to measure lumbar lordosis. In adult scoliosis patients, the measurement is difficult due to degenerative changes in the vertebral endplate as well as the coronal and sagittal deformity. We did the observational study with three examiners to determine the reliability of six methods for measuring the global lumbar lordosis in adult scoliosis patients. Ninety lateral lumbar radiographs were collected for the study. The radiographs were divided into normal (Cobb < 10°), low-grade (Cobb 10°–19°), high-grade (Cobb ≥ 20°) group to determine the reliability of Cobb L1–S1, Cobb L1–L5, centroid, posterior tangent L1–S1, posterior tangent L1–L5 and TRALL method in adult scoliosis. The 90 lateral radiographs were measured twice by each of the three examiners using the six measurement methods. The data was analyzed to determine the inter- and intra-observer reliability. In general, for the six radiographic methods, the inter- and intra-class correlation coefficients (ICCs) were all ≥0.82. A comparison of the ICCs and 95% CI for the inter- and intra-observer reliability between the groups with varying degrees of scoliosis showed that, the reliability of the lordosis measurement decreased with increasing severity of scoliosis. In Cobb L1–S1, centroid and posterior tangent L1–S1 methods, the ICCs were relatively lower in the high-grade scoliosis group (≥0.60). And, the mean absolute difference (MAD) in these methods was high in the high-grade scoliosis group (≤7.17°). However, in the Cobb L1–L5 and posterior tangent L1–L5 method, the ICCs were ≥0.86 in all groups. And, in the TRALL method, the ICCs were ≥0.76 in all groups. In addition, in the Cobb L1–L5 and posterior tangent L1–L5 method, the MAD was ≤3.63°. And, in the TRALL method, the MAD was ≤3.84° in all groups. We concluded that the Cobb L1–L5 and the posterior tangent L1–L5 methods are reliable methods for measuring the global lumbar lordosis in adult scoliosis. And the TRALL method is more reliable method than other methods which include the L5–S1 joint in lordosis measurement. PMID:20437183
On the design of high-rise buildings with a specified level of reliability
NASA Astrophysics Data System (ADS)
Dolganov, Andrey; Kagan, Pavel
2018-03-01
High-rise buildings have a specificity, which significantly distinguishes them from traditional buildings of high-rise and multi-storey buildings. Steel structures in high-rise buildings are advisable to be used in earthquake-proof regions, since steel, due to its plasticity, provides damping of the kinetic energy of seismic impacts. These aspects should be taken into account when choosing a structural scheme of a high-rise building and designing load-bearing structures. Currently, modern regulatory documents do not quantify the reliability of structures. Although the problem of assigning an optimal level of reliability has existed for a long time. The article shows the possibility of designing metal structures of high-rise buildings with specified reliability. Currently, modern regulatory documents do not quantify the reliability of high-rise buildings. Although the problem of assigning an optimal level of reliability has existed for a long time. It is proposed to establish the value of reliability 0.99865 (3σ) for constructions of buildings and structures of a normal level of responsibility in calculations for the first group of limiting states. For increased (construction of high-rise buildings) and reduced levels of responsibility for the provision of load-bearing capacity, it is proposed to assign respectively 0.99997 (4σ) and 0.97725 (2σ). The coefficients of the use of the cross section of a metal beam for different levels of security are given.
Oxygen production using solid-state zirconia electrolyte technology
NASA Technical Reports Server (NTRS)
Suitor, Jerry W.; Clark, Douglas J.
1991-01-01
High purity oxygen is required for a number of scientific, medical, and industrial applications. Traditionally, these needs have been met by cryogenic distillation or pressure swing adsorption systems designed to separate oxygen from air. Oxygen separation from air via solid-state zirconia electrolyte technology offers an alternative to these methods. The technology has several advantages over the traditional methods, including reliability, compactness, quiet operation, high purity output, and low power consumption.
High Throughput Determination of Tetramine in Drinking ...
Report The sampling and analytical procedure (SAP) presented herein, describes a method for the high throughput determination of tetramethylene disulfotetramine in drinking water by solid phase extraction and isotope dilution gas chromatography/mass spectrometry. This method, which will be included in the SAM, is expected to provide the Water Laboratory Alliance, as part of EPA’s Environmental Response Laboratory Network, with a more reliable and faster means of analyte collection and measurement.
Reliability of diagnosis and clinical efficacy of visceral osteopathy: a systematic review.
Guillaud, Albin; Darbois, Nelly; Monvoisin, Richard; Pinsault, Nicolas
2018-02-17
In 2010, the World Health Organization published benchmarks for training in osteopathy in which osteopathic visceral techniques are included. The purpose of this study was to identify and critically appraise the scientific literature concerning the reliability of diagnosis and the clinical efficacy of techniques used in visceral osteopathy. Databases MEDLINE, OSTMED.DR, the Cochrane Library, Osteopathic Research Web, Google Scholar, Journal of American Osteopathic Association (JAOA) website, International Journal of Osteopathic Medicine (IJOM) website, and the catalog of Académie d'ostéopathie de France website were searched through December 2017. Only inter-rater reliability studies including at least two raters or the intra-rater reliability studies including at least two assessments by the same rater were included. For efficacy studies, only randomized-controlled-trials (RCT) or crossover studies on unhealthy subjects (any condition, duration and outcome) were included. Risk of bias was determined using a modified version of the quality appraisal tool for studies of diagnostic reliability (QAREL) in reliability studies. For the efficacy studies, the Cochrane risk of bias tool was used to assess their methodological design. Two authors performed data extraction and analysis. Eight reliability studies and six efficacy studies were included. The analysis of reliability studies shows that the diagnostic techniques used in visceral osteopathy are unreliable. Regarding efficacy studies, the least biased study shows no significant difference for the main outcome. The main risks of bias found in the included studies were due to the absence of blinding of the examiners, an unsuitable statistical method or an absence of primary study outcome. The results of the systematic review lead us to conclude that well-conducted and sound evidence on the reliability and the efficacy of techniques in visceral osteopathy is absent. The review is registered PROSPERO 12th of December 2016. Registration number is CRD4201605286 .
Wang, Jin-Hui; Zuo, Xi-Nian; Gohel, Suril; Milham, Michael P.; Biswal, Bharat B.; He, Yong
2011-01-01
Graph-based computational network analysis has proven a powerful tool to quantitatively characterize functional architectures of the brain. However, the test-retest (TRT) reliability of graph metrics of functional networks has not been systematically examined. Here, we investigated TRT reliability of topological metrics of functional brain networks derived from resting-state functional magnetic resonance imaging data. Specifically, we evaluated both short-term (<1 hour apart) and long-term (>5 months apart) TRT reliability for 12 global and 6 local nodal network metrics. We found that reliability of global network metrics was overall low, threshold-sensitive and dependent on several factors of scanning time interval (TI, long-term>short-term), network membership (NM, networks excluding negative correlations>networks including negative correlations) and network type (NT, binarized networks>weighted networks). The dependence was modulated by another factor of node definition (ND) strategy. The local nodal reliability exhibited large variability across nodal metrics and a spatially heterogeneous distribution. Nodal degree was the most reliable metric and varied the least across the factors above. Hub regions in association and limbic/paralimbic cortices showed moderate TRT reliability. Importantly, nodal reliability was robust to above-mentioned four factors. Simulation analysis revealed that global network metrics were extremely sensitive (but varying degrees) to noise in functional connectivity and weighted networks generated numerically more reliable results in compared with binarized networks. For nodal network metrics, they showed high resistance to noise in functional connectivity and no NT related differences were found in the resistance. These findings provide important implications on how to choose reliable analytical schemes and network metrics of interest. PMID:21818285
Reliability analysis of the epidural spinal cord compression scale.
Bilsky, Mark H; Laufer, Ilya; Fourney, Daryl R; Groff, Michael; Schmidt, Meic H; Varga, Peter Paul; Vrionis, Frank D; Yamada, Yoshiya; Gerszten, Peter C; Kuklo, Timothy R
2010-09-01
The evolution of imaging techniques, along with highly effective radiation options has changed the way metastatic epidural tumors are treated. While high-grade epidural spinal cord compression (ESCC) frequently serves as an indication for surgical decompression, no consensus exists in the literature about the precise definition of this term. The advancement of the treatment paradigms in patients with metastatic tumors for the spine requires a clear grading scheme of ESCC. The degree of ESCC often serves as a major determinant in the decision to operate or irradiate. The purpose of this study was to determine the reliability and validity of a 6-point, MR imaging-based grading system for ESCC. To determine the reliability of the grading scale, a survey was distributed to 7 spine surgeons who participate in the Spine Oncology Study Group. The MR images of 25 cervical or thoracic spinal tumors were distributed consisting of 1 sagittal image and 3 axial images at the identical level including T1-weighted, T2-weighted, and Gd-enhanced T1-weighted images. The survey was administered 3 times at 2-week intervals. The inter- and intrarater reliability was assessed. The inter- and intrarater reliability ranged from good to excellent when surgeons were asked to rate the degree of spinal cord compression using T2-weighted axial images. The T2-weighted images were superior indicators of ESCC compared with T1-weighted images with and without Gd. The ESCC scale provides a valid and reliable instrument that may be used to describe the degree of ESCC based on T2-weighted MR images. This scale accounts for recent advances in the treatment of spinal metastases and may be used to provide an ESCC classification scheme for multicenter clinical trial and outcome studies.
Bulk electric system reliability evaluation incorporating wind power and demand side management
NASA Astrophysics Data System (ADS)
Huang, Dange
Electric power systems are experiencing dramatic changes with respect to structure, operation and regulation and are facing increasing pressure due to environmental and societal constraints. Bulk electric system reliability is an important consideration in power system planning, design and operation particularly in the new competitive environment. A wide range of methods have been developed to perform bulk electric system reliability evaluation. Theoretically, sequential Monte Carlo simulation can include all aspects and contingencies in a power system and can be used to produce an informative set of reliability indices. It has become a practical and viable tool for large system reliability assessment technique due to the development of computing power and is used in the studies described in this thesis. The well-being approach used in this research provides the opportunity to integrate an accepted deterministic criterion into a probabilistic framework. This research work includes the investigation of important factors that impact bulk electric system adequacy evaluation and security constrained adequacy assessment using the well-being analysis framework. Load forecast uncertainty is an important consideration in an electrical power system. This research includes load forecast uncertainty considerations in bulk electric system reliability assessment and the effects on system, load point and well-being indices and reliability index probability distributions are examined. There has been increasing worldwide interest in the utilization of wind power as a renewable energy source over the last two decades due to enhanced public awareness of the environment. Increasing penetration of wind power has significant impacts on power system reliability, and security analyses become more uncertain due to the unpredictable nature of wind power. The effects of wind power additions in generating and bulk electric system reliability assessment considering site wind speed correlations and the interactive effects of wind power and load forecast uncertainty on system reliability are examined. The concept of the security cost associated with operating in the marginal state in the well-being framework is incorporated in the economic analyses associated with system expansion planning including wind power and load forecast uncertainty. Overall reliability cost/worth analyses including security cost concepts are applied to select an optimal wind power injection strategy in a bulk electric system. The effects of the various demand side management measures on system reliability are illustrated using the system, load point, and well-being indices, and the reliability index probability distributions. The reliability effects of demand side management procedures in a bulk electric system including wind power and load forecast uncertainty considerations are also investigated. The system reliability effects due to specific demand side management programs are quantified and examined in terms of their reliability benefits.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-31
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [ Docket No. ER10-881-000] Reliable Power LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for Blanket... of Reliable Power, LLC's application for market-based rate authority, with an accompanying rate...
Energy Storage Technology Development for Space Exploration
NASA Technical Reports Server (NTRS)
Mercer, Carolyn R.; Jankovsky, Amy L.; Reid, Concha M.; Miller, Thomas B.; Hoberecht, Mark A.
2011-01-01
The National Aeronautics and Space Administration is developing battery and fuel cell technology to meet the expected energy storage needs of human exploration systems. Improving battery performance and safety for human missions enhances a number of exploration systems, including un-tethered extravehicular activity suits and transportation systems including landers and rovers. Similarly, improved fuel cell and electrolyzer systems can reduce mass and increase the reliability of electrical power, oxygen, and water generation for crewed vehicles, depots and outposts. To achieve this, NASA is developing non-flow-through proton-exchange-membrane fuel cell stacks, and electrolyzers coupled with low permeability membranes for high pressure operation. The primary advantage of this technology set is the reduction of ancillary parts in the balance-of-plant fewer pumps, separators and related components should result in fewer failure modes and hence a higher probability of achieving very reliable operation, and reduced parasitic power losses enable smaller reactant tanks and therefore systems with lower mass and volume. Key accomplishments over the past year include the fabrication and testing of several robust, small-scale non-flow-through fuel cell stacks that have demonstrated proof-of-concept. NASA is also developing advanced lithium-ion battery cells, targeting cell-level safety and very high specific energy and energy density. Key accomplishments include the development of silicon composite anodes, lithiatedmixed- metal-oxide cathodes, low-flammability electrolytes, and cell-incorporated safety devices that promise to substantially improve battery performance while providing a high level of safety.
Toward extending the educational interpreter performance assessment to cued speech.
Krause, Jean C; Kegl, Judy A; Schick, Brenda
2008-01-01
The Educational Interpreter Performance Assessment (EIPA) is as an important research tool for examining the quality of interpreters who use American Sign Language or a sign system in classroom settings, but it is not currently applicable to educational interpreters who use Cued Speech (CS). In order to determine the feasibility of extending the EIPA to include CS, a pilot EIPA test was developed and administered to 24 educational CS interpreters. Fifteen of the interpreters' performances were evaluated two to three times in order to assess reliability. Results show that the instrument has good construct validity and test-retest reliability. Although more interrater reliability data are needed, intrarater reliability was quite high (0.9), suggesting that the pilot test can be rated as reliably as signing versions of the EIPA. Notably, only 48% of interpreters who formally participated in pilot testing performed at a level that could be considered minimally acceptable. In light of similar performance levels previously reported for interpreters who sign (e.g., Schick, Williams, & Kupermintz, 2006), these results suggest that interpreting services for deaf and hard-of hearing students, regardless of the communication option used, are often inadequate and could seriously hinder access to the classroom environment.
Garcia, Darren J.; Skadberg, Rebecca M.; Schmidt, Megan; ...
2018-03-05
The Diagnostic and Statistical Manual of Mental Disorders (5th ed. [DSM–5]; American Psychiatric Association, 2013) Section III Alternative Model for Personality Disorders (AMPD) represents a novel approach to the diagnosis of personality disorder (PD). In this model, PD diagnosis requires evaluation of level of impairment in personality functioning (Criterion A) and characterization by pathological traits (Criterion B). Questions about clinical utility, complexity, and difficulty in learning and using the AMPD have been expressed in recent scholarly literature. We examined the learnability, interrater reliability, and clinical utility of the AMPD using a vignette methodology and graduate student raters. Results showed thatmore » student clinicians can learn Criterion A of the AMPD to a high level of interrater reliability and agreement with expert ratings. Interrater reliability of the 25 trait facets of the AMPD varied but showed overall acceptable levels of agreement. Examination of severity indexes of PD impairment showed the level of personality functioning (LPF) added information beyond that of global assessment of functioning (GAF). Clinical utility ratings were generally strong. Lastly, the satisfactory interrater reliability of components of the AMPD indicates the model, including the LPF, is very learnable.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garcia, Darren J.; Skadberg, Rebecca M.; Schmidt, Megan
The Diagnostic and Statistical Manual of Mental Disorders (5th ed. [DSM–5]; American Psychiatric Association, 2013) Section III Alternative Model for Personality Disorders (AMPD) represents a novel approach to the diagnosis of personality disorder (PD). In this model, PD diagnosis requires evaluation of level of impairment in personality functioning (Criterion A) and characterization by pathological traits (Criterion B). Questions about clinical utility, complexity, and difficulty in learning and using the AMPD have been expressed in recent scholarly literature. We examined the learnability, interrater reliability, and clinical utility of the AMPD using a vignette methodology and graduate student raters. Results showed thatmore » student clinicians can learn Criterion A of the AMPD to a high level of interrater reliability and agreement with expert ratings. Interrater reliability of the 25 trait facets of the AMPD varied but showed overall acceptable levels of agreement. Examination of severity indexes of PD impairment showed the level of personality functioning (LPF) added information beyond that of global assessment of functioning (GAF). Clinical utility ratings were generally strong. Lastly, the satisfactory interrater reliability of components of the AMPD indicates the model, including the LPF, is very learnable.« less
Reliability and cost analysis methods
NASA Technical Reports Server (NTRS)
Suich, Ronald C.
1991-01-01
In the design phase of a system, how does a design engineer or manager choose between a subsystem with .990 reliability and a more costly subsystem with .995 reliability? When is the increased cost justified? High reliability is not necessarily an end in itself but may be desirable in order to reduce the expected cost due to subsystem failure. However, this may not be the wisest use of funds since the expected cost due to subsystem failure is not the only cost involved. The subsystem itself may be very costly. We should not consider either the cost of the subsystem or the expected cost due to subsystem failure separately but should minimize the total of the two costs, i.e., the total of the cost of the subsystem plus the expected cost due to subsystem failure. This final report discusses the Combined Analysis of Reliability, Redundancy, and Cost (CARRAC) methods which were developed under Grant Number NAG 3-1100 from the NASA Lewis Research Center. CARRAC methods and a CARRAC computer program employ five models which can be used to cover a wide range of problems. The models contain an option which can include repair of failed modules.
Cintas, Holly Lea; Parks, Rebecca; Don, Sarah; Gerber, Lynn
2011-01-01
Content validity and reliability of the Brief Assessment of Motor Function (BAMF) Upper Extremity Gross Motor Scale (UEGMS) were evaluated in this prospective, descriptive study. The UEGMS is one of five ordinal scales designed for quick documentation of gross, fine and oral motor skill levels. Designed to be independent of age and diagnosis, it is intended for use for infants through young adults. An expert panel of 17 physical therapists and 13 occupational therapists refined the content by responding to a standard questionnaire comprised of questions which asked whether each item should be included, is clearly worded, should be reordered higher or lower, is functionally relevant, and is easily discriminated. Ratings of content validity exceeded the criterion except for two items which may represent different perspectives of physical and occupational therapists. The UEGMS was modified using the quantitative and qualitative feedback from the questionnaires. For reliability, five raters scored videotaped motor performances of ten children. Coefficients for inter-rater (0.94) and intra-rater (0.95) reliability were high. The results provide evidence of content validity and reliability of the UEGMS for assessment of upper extremity gross motor skill. PMID:21599568
Toward Extending the Educational Interpreter Performance Assessment to Cued Speech
Krause, Jean C.; Kegl, Judy A.; Schick, Brenda
2008-01-01
The Educational Interpreter Performance Assessment (EIPA) is as an important research tool for examining the quality of interpreters who use American Sign Language or a sign system in classroom settings, but it is not currently applicable to educational interpreters who use Cued Speech (CS). In order to determine the feasibility of extending the EIPA to include CS, a pilot EIPA test was developed and administered to 24 educational CS interpreters. Fifteen of the interpreters’ performances were evaluated two to three times in order to assess reliability. Results show that the instrument has good construct validity and test–retest reliability. Although more interrater reliability data are needed, intrarater reliability was quite high (0.9), suggesting that the pilot test can be rated as reliably as signing versions of the EIPA. Notably, only 48% of interpreters who formally participated in pilot testing performed at a level that could be considered minimally acceptable. In light of similar performance levels previously reported for interpreters who sign (e.g., Schick, Williams, & Kupermintz, 2006), these results suggest that interpreting services for deaf and hard-of hearing students, regardless of the communication option used, are often inadequate and could seriously hinder access to the classroom environment. PMID:18042791
Theory of reliable systems. [systems analysis and design
NASA Technical Reports Server (NTRS)
Meyer, J. F.
1973-01-01
The analysis and design of reliable systems are discussed. The attributes of system reliability studied are fault tolerance, diagnosability, and reconfigurability. Objectives of the study include: to determine properties of system structure that are conducive to a particular attribute; to determine methods for obtaining reliable realizations of a given system; and to determine how properties of system behavior relate to the complexity of fault tolerant realizations. A list of 34 references is included.
The welfare effects of integrating renewable energy into electricity markets
NASA Astrophysics Data System (ADS)
Lamadrid, Alberto J.
The challenges of deploying more renewable energy sources on an electric grid are caused largely by their inherent variability. In this context, energy storage can help make the electric delivery system more reliable by mitigating this variability. This thesis analyzes a series of models for procuring electricity and ancillary services for both individuals and social planners with high penetrations of stochastic wind energy. The results obtained for an individual decision maker using stochastic optimization are ambiguous, with closed form solutions dependent on technological parameters, and no consideration of the system reliability. The social planner models correctly reflect the effect of system reliability, and in the case of a Stochastic, Security Constrained Optimal Power Flow (S-SC-OPF or SuperOPF), determine reserve capacity endogenously so that system reliability is maintained. A single-period SuperOPF shows that including ramping costs in the objective function leads to more wind spilling and increased capacity requirements for reliability. However, this model does not reflect the inter temporal tradeoffs of using Energy Storage Systems (ESS) to improve reliability and mitigate wind variability. The results with the multiperiod SuperOPF determine the optimum use of storage for a typical day, and compare the effects of collocating ESS at wind sites with the same amount of storage (deferrable demand) located at demand centers. The collocated ESS has slightly lower operating costs and spills less wind generation compared to deferrable demand, but the total amount of conventional generating capacity needed for system adequacy is higher. In terms of the total system costs, that include the capital cost of conventional generating capacity, the costs with deferrable demand is substantially lower because the daily demand profile is flattened and less conventional generation capacity is then needed for reliability purposes. The analysis also demonstrates that the optimum daily pattern of dispatch and reserves is seriously distorted if the stochastic characteristics of wind generation are ignored.
Reliability and Validity Evidence of Multiple Balance Assessments in Athletes With a Concussion
Murray, Nicholas; Salvatore, Anthony; Powell, Douglas; Reed-Jones, Rebecca
2014-01-01
Context: An estimated 300 000 sport-related concussion injuries occur in the United States annually. Approximately 30% of individuals with concussions experience balance disturbances. Common methods of balance assessment include the Clinical Test of Sensory Organization and Balance (CTSIB), the Sensory Organization Test (SOT), the Balance Error Scoring System (BESS), and the Romberg test; however, the National Collegiate Athletic Association recommended the Wii Fit as an alternative measure of balance in athletes with a concussion. A central concern regarding the implementation of the Wii Fit is whether it is reliable and valid for measuring balance disturbance in athletes with concussion. Objective: To examine the reliability and validity evidence for the CTSIB, SOT, BESS, Romberg test, and Wii Fit for detecting balance disturbance in athletes with a concussion. Data Sources: Literature considered for review included publications with reliability and validity data for the assessments of balance (CTSIB, SOT, BESS, Romberg test, and Wii Fit) from PubMed, PsycINFO, and CINAHL. Data Extraction: We identified 63 relevant articles for consideration in the review. Of the 63 articles, 28 were considered appropriate for inclusion and 35 were excluded. Data Synthesis: No current reliability or validity information supports the use of the CTSIB, SOT, Romberg test, or Wii Fit for balance assessment in athletes with a concussion. The BESS demonstrated moderate to high reliability (interclass correlation coefficient = 0.87) and low to moderate validity (sensitivity = 34%, specificity = 87%). However, the Romberg test and Wii Fit have been shown to be reliable tools in the assessment of balance in Parkinson patients. Conclusions: The BESS can evaluate balance problems after a concussion. However, it lacks the ability to detect balance problems after the third day of recovery. Further investigation is needed to establish the use of the CTSIB, SOT, Romberg test, and Wii Fit for assessing balance in athletes with concussions. PMID:24933431
Research on the high-precision non-contact optical detection technology for banknotes
NASA Astrophysics Data System (ADS)
Jin, Xiaofeng; Liang, Tiancai; Luo, Pengfeng; Sun, Jianfeng
2015-09-01
The technology of high-precision laser interferometry was introduced for optical measurement of the banknotes in this paper. Taking advantage of laser short wavelength and high sensitivity, information of adhesive tape and cavity about the banknotes could be checked efficiently. Compared with current measurement devices, including mechanical wheel measurement device, Infrared measurement device, ultrasonic measurement device, the laser interferometry measurement has higher precision and reliability. This will improve the ability of banknotes feature information in financial electronic equipment.
MEMS reliability: coming of age
NASA Astrophysics Data System (ADS)
Douglass, Michael R.
2008-02-01
In today's high-volume semiconductor world, one could easily take reliability for granted. As the MOEMS/MEMS industry continues to establish itself as a viable alternative to conventional manufacturing in the macro world, reliability can be of high concern. Currently, there are several emerging market opportunities in which MOEMS/MEMS is gaining a foothold. Markets such as mobile media, consumer electronics, biomedical devices, and homeland security are all showing great interest in microfabricated products. At the same time, these markets are among the most demanding when it comes to reliability assurance. To be successful, each company developing a MOEMS/MEMS device must consider reliability on an equal footing with cost, performance and manufacturability. What can this maturing industry learn from the successful development of DLP technology, air bag accelerometers and inkjet printheads? This paper discusses some basic reliability principles which any MOEMS/MEMS device development must use. Examples from the commercially successful and highly reliable Digital Micromirror Device complement the discussion.
Space Shuttle Propulsion System Reliability
NASA Technical Reports Server (NTRS)
Welzyn, Ken; VanHooser, Katherine; Moore, Dennis; Wood, David
2011-01-01
This session includes the following sessions: (1) External Tank (ET) System Reliability and Lessons, (2) Space Shuttle Main Engine (SSME), Reliability Validated by a Million Seconds of Testing, (3) Reusable Solid Rocket Motor (RSRM) Reliability via Process Control, and (4) Solid Rocket Booster (SRB) Reliability via Acceptance and Testing.
NASA Astrophysics Data System (ADS)
Blair, J. B.; Rabine, D.; Hofton, M. A.; Citrin, E.; Luthcke, S. B.; Misakonis, A.; Wake, S.
2015-12-01
Full waveform laser altimetry has demonstrated its ability to capture highly-accurate surface topography and vertical structure (e.g. vegetation height and structure) even in the most challenging conditions. NASA's high-altitude airborne laser altimeter, LVIS (the Land Vegetation, and Ice Sensor) has produced high-accuracy surface maps over a wide variety of science targets for the last 2 decades. Recently NASA has funded the transition of LVIS into a full-time NASA airborne Facility instrument to increase the amount and quality of the data and to decrease the end-user costs, to expand the utilization and application of this unique sensor capability. Based heavily on the existing LVIS sensor design, the Facility LVIS instrument includes numerous improvements for reliability, resolution, real-time performance monitoring and science products, decreased operational costs, and improved data turnaround time and consistency. The development of this Facility instrument is proceeding well and it is scheduled to begin operations testing in mid-2016. A comprehensive description of the LVIS Facility capability will be presented along with several mission scenarios and science applications examples. The sensor improvements included increased spatial resolution (footprints as small as 5 m), increased range precision (sub-cm single shot range precision), expanded dynamic range, improved detector sensitivity, operational autonomy, real-time flight line tracking, and overall increased reliability and sensor calibration stability. The science customer mission planning and data product interface will be discussed. Science applications of the LVIS Facility include: cryosphere, territorial ecology carbon cycle, hydrology, solid earth and natural hazards, and biodiversity.
Advanced flight control system study
NASA Technical Reports Server (NTRS)
Hartmann, G. L.; Wall, J. E., Jr.; Rang, E. R.; Lee, H. P.; Schulte, R. W.; Ng, W. K.
1982-01-01
A fly by wire flight control system architecture designed for high reliability includes spare sensor and computer elements to permit safe dispatch with failed elements, thereby reducing unscheduled maintenance. A methodology capable of demonstrating that the architecture does achieve the predicted performance characteristics consists of a hierarchy of activities ranging from analytical calculations of system reliability and formal methods of software verification to iron bird testing followed by flight evaluation. Interfacing this architecture to the Lockheed S-3A aircraft for flight test is discussed. This testbed vehicle can be expanded to support flight experiments in advanced aerodynamics, electromechanical actuators, secondary power systems, flight management, new displays, and air traffic control concepts.
Sandia and NJ TRANSIT Authority Developing Resilient Power Grid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanley, Charles J.; Ellis, Abraham
2014-11-01
Through the memorandum of understanding between the Depratment of Energy (DOE), the New Jersey Transit Authority (NJ Transit), and the New Jersey Board of Public Utilities, Sandia National Labs is assisting NJ Transit in developing NJ TransitGrid: an electric microgrid that will include a large-scale gas-fired generation facility and distributed energy resources (photovoltaics [PV], energy storage, electric vehicles, combined heat and power [CHP]) to supply reliable power during storms or other times of significant power failure. The NJ TransitGrid was awarded $410M from the Department of Transportation to develop a first-of-its-kind electric microgrid capable of supplying highly-reliable power.
Reliability, validity, and significance of assessment of sense of contribution in the workplace.
Takaki, Jiro; Taniguchi, Toshiyo; Fujii, Yasuhito
2014-01-29
The purpose of this study was to assess the validity and reliability of the Sense of Contribution Scale (SCS), a newly developed, 7-item questionnaire used to measure sense of contribution in the workplace. Workers at 272 organizations answered questionnaires that included the SCS. Because of non-participation or missing data, the number of subjects included in the analyses for internal consistency and validity varied from 1,675 to 2,462 (response rates 54.6%-80.2%). Fifty-four workers were included in the analysis of test-retest reliability (response rate, 77.1%). The SCS showed high internal consistency (Cronbach's α coefficients in men and women were 0.85 and 0.86, respectively) and test-retest reliability (intraclass correlation coefficient = 0.91). Significant (p < 0.001), positive, moderate correlations were found between the SCS score and scores for organization-based self-esteem and work engagement in both genders, which support the SCS's convergent and discriminant validity. The criterion validity of the SCS was supported by the finding that in both genders, the SCS scores were significantly (p < 0.05) and inversely associated with psychological distress and sleep disturbance in crude and in multivariable analyses that adjusted for demographics, organization-based self-esteem, work engagement, effort-reward ratio, workplace bullying, and procedural and interactional justice. The SCS is a psychometrically satisfactory measure of sense of contribution in the workplace. The SCS provides a new and useful instrument to measure sense of contribution, which is independently associated with mental health in workers, for studies in organizational science, occupational health psychology and occupational medicine.
Reliability, Validity, and Significance of Assessment of Sense of Contribution in the Workplace
Takaki, Jiro; Taniguchi, Toshiyo; Fujii, Yasuhito
2014-01-01
The purpose of this study was to assess the validity and reliability of the Sense of Contribution Scale (SCS), a newly developed, 7-item questionnaire used to measure sense of contribution in the workplace. Workers at 272 organizations answered questionnaires that included the SCS. Because of non-participation or missing data, the number of subjects included in the analyses for internal consistency and validity varied from 1,675 to 2,462 (response rates 54.6%–80.2%). Fifty-four workers were included in the analysis of test–retest reliability (response rate, 77.1%). The SCS showed high internal consistency (Cronbach’s α coefficients in men and women were 0.85 and 0.86, respectively) and test–retest reliability (intraclass correlation coefficient = 0.91). Significant (p < 0.001), positive, moderate correlations were found between the SCS score and scores for organization-based self-esteem and work engagement in both genders, which support the SCS’s convergent and discriminant validity. The criterion validity of the SCS was supported by the finding that in both genders, the SCS scores were significantly (p < 0.05) and inversely associated with psychological distress and sleep disturbance in crude and in multivariable analyses that adjusted for demographics, organization-based self-esteem, work engagement, effort–reward ratio, workplace bullying, and procedural and interactional justice. The SCS is a psychometrically satisfactory measure of sense of contribution in the workplace. The SCS provides a new and useful instrument to measure sense of contribution, which is independently associated with mental health in workers, for studies in organizational science, occupational health psychology and occupational medicine. PMID:24481035
Terashima, Taiko; Yoshimura, Sadako
2018-03-01
To determine whether nurses can accurately assess the skin colour of replanted fingers displayed as digital images on a computer screen. Colour measurement and clinical diagnostic methods for medical digital images have been studied, but reproducing skin colour on a computer screen remains difficult. The inter-rater reliability of skin colour assessment scores was evaluated. In May 2014, 21 nurses who worked on a trauma ward in Japan participated in testing. Six digital images with different skin colours were used. Colours were scored from both digital images and direct patient's observation. The score from a digital image was defined as the test score, and its difference from the direct assessment score as the difference score. Intraclass correlation coefficients were calculated. Nurses' opinions were classified and summarised. The intraclass correlation coefficients for the test scores were fair. Although the intraclass correlation coefficients for the difference scores were poor, they improved to good when three images that might have contributed to poor reliability were excluded. Most nurses stated that it is difficult to assess skin colour in digital images; they did not think it could be a substitute for direct visual assessment. However, most nurses were in favour of including images in nursing progress notes. Although the inter-rater reliability was fairly high, the reliability of colour reproduction in digital images as indicated by the difference scores was poor. Nevertheless, nurses expect the incorporation of digital images in nursing progress notes to be useful. This gap between the reliability of digital colour reproduction and nurses' expectations towards it must be addressed. High inter-rater reliability for digital images in nursing progress notes was not observed. Assessments of future improvements in colour reproduction technologies are required. Further digitisation and visualisation of nursing records might pose challenges. © 2017 John Wiley & Sons Ltd.
ERIC Educational Resources Information Center
Lorton, Juli A.; Bellamy, G. Thomas; Reece, Anne; Carlson, Jill
2013-01-01
Drawing on research on high-reliability organizations, this interviewbased qualitative case study employs four characteristics of such organizations as a lens for analyzing the operations of one very successful K-5 public school. Results suggest that the school had processes similar to those characteristic of high-reliability organizations: a…
Development and Validation of the Appearance and Performance Enhancing Drug Use Schedule
Langenbucher, James W.; Lai, Justine Karmin; Loeb, Katharine L.; Hollander, Eric
2011-01-01
Appearance-and-performance enhancing drug (APED) use is a form of drug use that includes use of a wide range of substances such as anabolic-androgenic steroids (AASs) and associated behaviors including intense exercise and dietary control. To date, there are no reliable or valid measures of the core features of APED use. The present study describes the development and psychometric evaluation of the Appearance and Performance Enhancing Drug Use Schedule (APEDUS) which is a semi-structured interview designed to assess the spectrum of drug use and related features of APED use. Eighty-five current APED using men and women (having used an illicit APED in the past year and planning to use an illicit APED in the future) completed the APEDUS and measures of convergent and divergent validity. Inter-rater agreement, scale reliability, one-week test-retest reliability, convergent and divergent validity, and construct validity were evaluated for each of the APEDUS scales. The APEDUS is a modular interview with 10 sections designed to assess the core drug and non-drug phenomena associated with APED use. All scales and individual items demonstrated high inter-rater agreement and reliability. Individual scales significantly correlated with convergent measures (DSM-IV diagnoses, aggression, impulsivity, eating disorder pathology) and were uncorrelated with a measure of social desirability. APEDUS subscale scores were also accurate measures of AAS dependence. The APEDUS is a reliable and valid measure of APED phenomena and an accurate measure of the core pathology associated with APED use. Issues with assessing APED use are considered and future research considered. PMID:21640487
Making literature reviews more reliable through application of lessons from systematic reviews.
Haddaway, N R; Woodcock, P; Macura, B; Collins, A
2015-12-01
Review articles can provide valuable summaries of the ever-increasing volume of primary research in conservation biology. Where findings may influence important resource-allocation decisions in policy or practice, there is a need for a high degree of reliability when reviewing evidence. However, traditional literature reviews are susceptible to a number of biases during the identification, selection, and synthesis of included studies (e.g., publication bias, selection bias, and vote counting). Systematic reviews, pioneered in medicine and translated into conservation in 2006, address these issues through a strict methodology that aims to maximize transparency, objectivity, and repeatability. Systematic reviews will always be the gold standard for reliable synthesis of evidence. However, traditional literature reviews remain popular and will continue to be valuable where systematic reviews are not feasible. Where traditional reviews are used, lessons can be taken from systematic reviews and applied to traditional reviews in order to increase their reliability. Certain key aspects of systematic review methods that can be used in a context-specific manner in traditional reviews include focusing on mitigating bias; increasing transparency, consistency, and objectivity, and critically appraising the evidence and avoiding vote counting. In situations where conducting a full systematic review is not feasible, the proposed approach to reviewing evidence in a more systematic way can substantially improve the reliability of review findings, providing a time- and resource-efficient means of maximizing the value of traditional reviews. These methods are aimed particularly at those conducting literature reviews where systematic review is not feasible, for example, for graduate students, single reviewers, or small organizations. © 2015 Society for Conservation Biology.
NASA Technical Reports Server (NTRS)
White, Mark; Huang, Bing; Qin, Jin; Gur, Zvi; Talmor, Michael; Chen, Yuan; Heidecker, Jason; Nguyen, Duc; Bernstein, Joseph
2005-01-01
As microelectronics are scaled in to the deep sub-micron regime, users of advanced technology CMOS, particularly in high-reliability applications, should reassess how scaling effects impact long-term reliability. An experimental based reliability study of industrial grade SRAMs, consisting of three different technology nodes, is proposed to substantiate current acceleration models for temperature and voltage life-stress relationships. This reliability study utilizes step-stress techniques to evaluate memory technologies (0.25mum, 0.15mum, and 0.13mum) embedded in many of today's high-reliability space/aerospace applications. Two acceleration modeling approaches are presented to relate experimental FIT calculations to Mfr's qualification data.
Learning from escaped prescribed fire reviews
Anne E. Black; Dave Thomas; James Saveland; Jennifer D. Ziegler
2011-01-01
The U.S. wildland fire community has developed a number of innovative methods for conducting a review following escape of a prescribed fire (expanding on the typical regional or local reviews, to include more of a learning focus - expanded After Action Reviews, reviews that incorporate High Reliability Organizing, Facilitated Learning Analyses, etc). The stated purpose...
ERIC Educational Resources Information Center
Floman, James L.; Hagelskamp, Carolin; Brackett, Marc A.; Rivers, Susan E.
2017-01-01
Classroom observations increasingly inform high-stakes decisions and research in education, including the allocation of school funding and the evaluation of school-based interventions. However, trends in rater scoring tendencies over time may undermine the reliability of classroom observations. Accordingly, the present investigations, grounded in…
NASA Technical Reports Server (NTRS)
Meyers, A. P.; Davidson, W. A.; Gortowski, R. C.
1973-01-01
Detailed drawings of the five year tape transport are presented. Analytical tools used in the various analyses are described. These analyses include: tape guidance, tape stress over crowned rollers, tape pack stress program, response (computer) program, and control system electronics description.
Stirling engines for automobiles
NASA Technical Reports Server (NTRS)
Beremand, D. G.
1979-01-01
The results of recent and ongoing automobile Stirling engine development efforts are reviewed and technology status and requirements are identified. Key technology needs include those for low cost, high temperature (1300 - 1500 F) metal alloys for heater heads, and reliable long-life, low-leakage shaft seals. Various fuel economy projections for Stirling powered automobiles are reviewed and assessed.
Library Blogs: What's Most Important for Success within the Enterprise?
ERIC Educational Resources Information Center
Bardyn, Tania P.
2009-01-01
Library blogs exchange information and ideas on everything from the everyday, such as library services, to the profound, such as values held by librarians (high-quality reliable resources, academic freedom, open access, and so on). According to medical librarians who maintain library blogs, a typical month includes two to four contributors writing…
Evaluation of Advanced COTS Passive Devices for Extreme Temperature Operation
NASA Technical Reports Server (NTRS)
Patterson, Richard; Hammoud, Ahmad; Dones, Keishla R.
2009-01-01
Electronic sensors and circuits are often exposed to extreme temperatures in many of NASA deep space and planetary surface exploration missions. Electronics capable of operation in harsh environments would be beneficial as they simplify overall system design, relax thermal management constraints, and meet operational requirements. For example, cryogenic operation of electronic parts will improve reliability, increase energy density, and extend the operational lifetimes of space-based electronic systems. Similarly, electronic parts that are able to withstand and operate efficiently in high temperature environments will negate the need for thermal control elements and their associated structures, thereby reducing system size and weight, enhancing its reliability, improving its efficiency, and reducing cost. Passive devices play a critical role in the design of almost all electronic circuitry. To address the needs of systems for extreme temperature operation, some of the advanced and most recently introduced commercial-off-the-shelf (COTS) passive devices, which included resistors and capacitors, were examined for operation under a wide temperature regime. The types of resistors investigated included high temperature precision film, general purpose metal oxide, and wirewound.
NASA Technical Reports Server (NTRS)
Eichenberg, Dennis J.
2007-01-01
The NASA Glenn Research Center s Avionics, Power and Communications Branch of the Engineering and Systems Division initiated the Hybrid Power Management (HPM) Program for the GRC Technology Transfer and Partnership Office. HPM is the innovative integration of diverse, state-of-the-art power devices in an optimal configuration for space and terrestrial applications. The appropriate application and control of the various power devices significantly improves overall system performance and efficiency. The advanced power devices include ultracapacitors and fuel cells. HPM has extremely wide potential. Applications include power generation, transportation systems, biotechnology systems, and space power systems. HPM has the potential to significantly alleviate global energy concerns, improve the environment, and stimulate the economy. One of the unique power devices being utilized by HPM for energy storage is the ultracapacitor. An ultracapacitor is an electrochemical energy storage device, which has extremely high volumetric capacitance energy due to high surface area electrodes, and very small electrode separation. Ultracapacitors are a reliable, long life, maintenance free, energy storage system. This flexible operating system can be applied to all power systems to significantly improve system efficiency, reliability, and performance. There are many existing and conceptual applications of HPM.
In-Vivo Human Skin to Textiles Friction Measurements
NASA Astrophysics Data System (ADS)
Pfarr, Lukas; Zagar, Bernhard
2017-10-01
We report on a measurement system to determine highly reliable and accurate friction properties of textiles as needed for example as input to garment simulation software. Our investigations led to a set-up that allows to characterize not just textile to textile but also textile to in-vivo human skin tribological properties and thus to fundamental knowledge about genuine wearer interaction in garments. The method of test conveyed in this paper is measuring concurrently and in a highly time resolved manner the normal force as well as the resulting shear force caused by a friction subject intending to slide out of the static friction regime and into the dynamic regime on a test bench. Deeper analysis of various influences is enabled by extending the simple model following Coulomb's law for rigid body friction to include further essential parameters such as contact force, predominance in the yarn's orientation and also skin hydration. This easy-to-use system enables to measure reliably and reproducibly both static and dynamic friction for a variety of friction partners including human skin with all its variability there might be.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grabaskas, David; Brunett, Acacia J.; Passerini, Stefano
GE Hitachi Nuclear Energy (GEH) and Argonne National Laboratory (Argonne) participated in a two year collaboration to modernize and update the probabilistic risk assessment (PRA) for the PRISM sodium fast reactor. At a high level, the primary outcome of the project was the development of a next-generation PRA that is intended to enable risk-informed prioritization of safety- and reliability-focused research and development. A central Argonne task during this project was a reliability assessment of passive safety systems, which included the Reactor Vessel Auxiliary Cooling System (RVACS) and the inherent reactivity feedbacks of the metal fuel core. Both systems were examinedmore » utilizing a methodology derived from the Reliability Method for Passive Safety Functions (RMPS), with an emphasis on developing success criteria based on mechanistic system modeling while also maintaining consistency with the Fuel Damage Categories (FDCs) of the mechanistic source term assessment. This paper provides an overview of the reliability analyses of both systems, including highlights of the FMEAs, the construction of best-estimate models, uncertain parameter screening and propagation, and the quantification of system failure probability. In particular, special focus is given to the methodologies to perform the analysis of uncertainty propagation and the determination of the likelihood of violating FDC limits. Additionally, important lessons learned are also reviewed, such as optimal sampling methodologies for the discovery of low likelihood failure events and strategies for the combined treatment of aleatory and epistemic uncertainties.« less
Environmental and reliability test of FBG based geophone as geophysical exploration instrument
NASA Astrophysics Data System (ADS)
Zhang, Xiaolei; Min, Li; Li, Ming; Jiang, Shaodong; Zhang, Faxiang; Sun, Zhihui; Ni, Jiasheng; Peng, Gangding; Wang, Chang
2017-10-01
A fiber Bragg grating (FBG) based geophone is designed for low-frequency signal detection has high acceleration response of about 60 dB re pm/g in a low frequency range of 5 Hz 60 Hz. To Guarantee normal operation in field test and practical application, an acceleration amplitude restriction is added in the mechanical design of the FBG geophone. Then a series of environmental and reliability test have been proceeded with online or offline monitoring of its working performance, including high and low temperature test, vibration test, shock test and free drop test. All the tests are planned according to National standard or Oil & Gas Industry Standard. And the experimental results indicate that our FBG geophone meet the criterion of oil and gas industry product and is capable of field application.
NASA Astrophysics Data System (ADS)
Vatanparast, Maryam; Vullum, Per Erik; Nord, Magnus; Zuo, Jian-Min; Reenaas, Turid W.; Holmestad, Randi
2017-09-01
Geometric phase analysis (GPA), a fast and simple Fourier space method for strain analysis, can give useful information on accumulated strain and defect propagation in multiple layers of semiconductors, including quantum dot materials. In this work, GPA has been applied to high resolution Z-contrast scanning transmission electron microscopy (STEM) images. Strain maps determined from different g vectors of these images are compared to each other, in order to analyze and assess the GPA technique in terms of accuracy. The SmartAlign tool has been used to improve the STEM image quality getting more reliable results. Strain maps from template matching as a real space approach are compared with strain maps from GPA, and it is discussed that a real space analysis is a better approach than GPA for aberration corrected STEM images.
Ilyin, S E; Plata-Salamán, C R
2000-02-15
Homogenization of tissue samples is a common first step in the majority of current protocols for RNA, DNA, and protein isolation. This report describes a simple device for centrifugation-mediated homogenization of tissue samples. The method presented is applicable to RNA, DNA, and protein isolation, and we show examples where high quality total cell RNA, DNA, and protein were obtained from brain and other tissue samples. The advantages of the approach presented include: (1) a significant reduction in time investment relative to hand-driven or individual motorized-driven pestle homogenization; (2) easy construction of the device from inexpensive parts available in any laboratory; (3) high replicability in the processing; and (4) the capacity for the parallel processing of multiple tissue samples, thus allowing higher efficiency, reliability, and standardization.
dos Santos, W D; Ferrarese, Maria de Lourdes Lucio; Ferrarese-Filho, O
2006-01-01
This study proposes a simple, quick and reliable method for determining the cinnamyl alcohol dehydrogenase (CAD; EC 1.1.1.195) activity in soybean (Glycine max L. Merr.) roots using reversed-phase high performance liquid chromatography (RP-HPLC). The method includes a single extraction of the tissue and conduction of the enzymatic reaction at 30 degrees C with cinnamaldehydes (coniferyl or sinapyl), substrates of CAD. Disappearance of the substrates in the reaction mixture is monitored at 340 nm (for coniferaldehyde) or 345 nm (for sinapaldehyde) by isocratic elution with methanol/acetic acid through a GLC-ODS (M) column. This HPLC technique furnishes a rapid and reliable measure of cinnamaldehyde substrates, and may be used as an alternative tool to analyze CAD activity in enzyme preparation without previous purification.
Optical detection of metastatic cancer cells using a scanned laser pico-projection system
NASA Astrophysics Data System (ADS)
Huang, Chih-Ling; Chiu, Wen-Tai; Lo, Yu-Lung; Chuang, Chin-Ho; Chen, Yu-Bin; Chang, Shu-Jing; Ke, Tung-Ting; Cheng, Hung-Chi; Wu, Hua-Lin
2015-03-01
Metastasis is responsible for 90% of all cancer-related deaths in humans. As a result, reliable techniques for detecting metastatic cells are urgently required. Although various techniques have been proposed for metastasis detection, they are generally capable of detecting metastatic cells only once migration has already occurred. Accordingly, the present study proposes an optical method for physical characterization of metastatic cancer cells using a scanned laser pico-projection system (SLPP). The validity of the proposed method is demonstrated using five pairs of cancer cell lines and two pairs of non-cancer cell lines treated by IPTG induction in order to mimic normal cells with an overexpression of oncogene. The results show that for all of the considered cell lines, the SLPP speckle contrast of the high-metastatic cells is significantly higher than that of the low-metastatic cells. As a result, the speckle contrast measurement provides a reliable means of distinguishing quantitatively between low- and high-metastatic cells of the same origin. Compared to existing metastasis detection methods, the proposed SLPP approach has many advantages, including a higher throughput, a lower cost, a larger sample size and a more reliable diagnostic performance. As a result, it provides a highly promising solution for physical characterization of metastatic cancer cells in vitro.
Moore, Amy Lawson; Miller, Terissa M
2018-01-01
The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills. This study included 2,737 participants aged 5-85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test-retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement. Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test-retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93. The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan.
Measurement of students' perceptions of nursing as a career.
Matutina, Robin E; Newman, Susan D; Jenkins, Carolyn M
2010-09-01
Middle school has been identified as the prime age group to begin nursing recruitment efforts because students have malleable perceptions about nursing as a future career choice. The purpose of this integrative review is to present a brief overview of research processes related to middle school students' perceptions of nursing as a future career choice and to critically evaluate the current instruments used to measure middle and high school students' perceptions of nursing as a career choice. An integrative review of the years 1989 to 2009 was conducted searching Cumulative Index to Nursing and Allied Health Literature (CINAHL), National Library of Medicine PubMed service (PubMed), and Ovid MEDLINE databases using the key words career, choice, future, ideal, nursing, and perception. Reference lists of retrieved studies were hand searched, yielding a total of 22 studies. Inclusion criteria were (a) sample of middle school students, (b) sample of high school students, (c) mixed sample including middle or high school students, and (4) samples other than middle or high school students if the instrument was tested with middle or high school students in a separate study. Ten studies met these criteria. Of the 10 studies, samples were 30% middle school students; 40% high school students; 10% mixed, including school-aged students; and 20% college students with an instrument tested in middle school students. Eighty percent of participants were White females. Overall, participants' socioeconomic status was not identified. A single study included a theoretical framework. Five instruments were identified and each could be completed in 15 to 30 min. The most commonly used instrument is available free of charge. Seventy percent of the studies used Cronbach's alpha to report instrument reliability (0.63 to 0.93), whereas 30% failed to report reliability. Fifty percent of the studies established validity via a "panel of experts," with three of those studies further describing the panel of experts. Samples of white females may hinder generalization. Socioeconomic status was not consistently reported and may be an important factor with regard to perceptions of nursing as a career choice. An overall absence of theoretical framework hinders empirical data from being applied to nursing theories that in turn may support nursing concepts. The reporting of reliability and validity may be improved by further defining panel of experts and expanding the number of experts (more than seven). More in-depth evaluation of the psychometric properties of the instruments with more diverse populations is needed. Rigorously tested instruments may be useful in determining middle school students' perceptions about nursing. Therefore, future researchers should consider testing existing instruments in the middle school population, adhering to theoretical frameworks, diversifying the sample population, and clearly reporting reliability and validity to gain knowledge about middle school students' perceptions about a nursing career.
1984-03-01
Engineering initiative to develop an orderly plan and procedure to assure that USAF acquire reliable, high quality, supportable avionics with a higher avail...susceptibility te~t~ (radiated and conducted), and emission of radio frequency energy tests."l6) Other electrical stresses can include over/under voltage...jo ints, poor welds, and dielectric defects. Also, instruments with components unable to endu very high temperatures can be safely tested. 1-19
Microgrids and distributed generation systems: Control, operation, coordination and planning
NASA Astrophysics Data System (ADS)
Che, Liang
Distributed Energy Resources (DERs) which include distributed generations (DGs), distributed energy storage systems, and adjustable loads are key components in microgrid operations. A microgrid is a small electric power system integrated with on-site DERs to serve all or some portion of the local load and connected to the utility grid through the point of common coupling (PCC). Microgrids can operate in both grid-connected mode and island mode. The structure and components of hierarchical control for a microgrid at Illinois Institute of Technology (IIT) are discussed and analyzed. Case studies would address the reliable and economic operation of IIT microgrid. The simulation results of IIT microgrid operation demonstrate that the hierarchical control and the coordination strategy of distributed energy resources (DERs) is an effective way of optimizing the economic operation and the reliability of microgrids. The benefits and challenges of DC microgrids are addressed with a DC model for the IIT microgrid. We presented the hierarchical control strategy including the primary, secondary, and tertiary controls for economic operation and the resilience of a DC microgrid. The simulation results verify that the proposed coordinated strategy is an effective way of ensuring the resilient response of DC microgrids to emergencies and optimizing their economic operation at steady state. The concept and prototype of a community microgrid that interconnecting multiple microgrids in a community are proposed. Two works are conducted. For the coordination, novel three-level hierarchical coordination strategy to coordinate the optimal power exchanges among neighboring microgrids is proposed. For the planning, a multi-microgrid interconnection planning framework using probabilistic minimal cut-set (MCS) based iterative methodology is proposed for enhancing the economic, resilience, and reliability signals in multi-microgrid operations. The implementation of high-reliability microgrids requires proper protection schemes that effectively function in both grid-connected and island modes. This chapter presents a communication-assisted four-level hierarchical protection strategy for high-reliability microgrids, and tests the proposed protection strategy based on a loop structured microgrid. The simulation results demonstrate the proposed strategy to be an effective and efficient option for microgrid protection. Additionally, microgrid topology ought to be optimally planned. To address the microgrid topology planning, a graph-partitioning and integer-programming integrated methodology is proposed. This work is not included in the dissertation. Interested readers can refer to our related publication.
Test-Retest Reliability of the Short-Form Survivor Unmet Needs Survey.
Taylor, Karen; Bulsara, Max; Monterosso, Leanne
2018-01-01
Reliable and valid needs assessment measures are important assessment tools in cancer survivorship care. A new 30-item short-form version of the Survivor Unmet Needs Survey (SF-SUNS) was developed and validated with cancer survivors, including hematology cancer survivors; however, test-retest reliability has not been established. The objective of this study was to assess the test-retest reliability of the SF-SUNS with a cohort of lymphoma survivors ( n = 40). Test-retest reliability of the SF-SUNS was conducted at two time points: baseline (time 1) and 5 days later (time 2). Test-retest data were collected from lymphoma cancer survivors ( n = 40) in a large tertiary cancer center in Western Australia. Intraclass correlation analyses compared data at time 1 (baseline) and time 2 (5 days later). Cronbach's alpha analyses were performed to assess the internal consistency at both time points. The majority (23/30, 77%) of items achieved test-retest reliability scores 0.45-0.74 (fair to good). A high degree of overall internal consistency was demonstrated (time 1 = 0.92, time 2 = 0.95), with scores 0.65-0.94 across subscales for both time points. Mixed test-retest reliability of the SF-SUNS was established. Our results indicate the SF-SUNS is responsive to the changing needs of lymphoma cancer survivors. Routine use of cancer survivorship specific needs-based assessments is required in oncology care today. Nurses are well placed to administer these assessments and provide tailored information and resources. Further assessment of test-retest reliability in hematology and other cancer cohorts is warranted.
Reliability of bounce drop jump parameters within elite male rugby players.
Costley, Lisa; Wallace, Eric; Johnston, Michael; Kennedy, Rodney
2017-07-25
The aims of the study were to investigate the number of familiarisation sessions required to establish reliability of the bounce drop jump (BDJ) and subsequent reliability once familiarisation is achieved. Seventeen trained male athletes completed 4 BDJs in 4 separate testing sessions. Force-time data from a 20 cm BDJ was obtained using two force plates (ensuring ground contact < 250 ms). Subjects were instructed to 'jump for maximal height and minimal contact time' while the best and average of four jumps were compared. A series of performance variables were assessed in both eccentric and concentric phases including jump height, contact time, flight time, reactive strength index (RSI), peak power, rate of force development (RFD) and actual dropping height (ADH). Reliability was assessed using the intraclass correlation coefficient (ICC) and coefficient of variation (CV) while familiarisation was assessed using a repeated measures analysis of variance (ANOVA). The majority of DJ parameters exhibited excellent reliability with no systematic bias evident, while the average of 4 trials provided greater reliability. With the exception of vertical stiffness (CV: 12.0 %) and RFD (CV: 16.2 %) all variables demonstrated low within subject variation (CV range: 3.1 - 8.9 %). Relative reliability was very poor for ADH, with heights ranging from 14.87 - 29.85 cm. High levels of reliability can be obtained from the BDJ with the exception of vertical stiffness and RFD, however, extreme caution must be taken when comparing DJ results between individuals and squads due to large discrepancies between actual drop height and platform height.
Daniels, Vijay J; Bordage, Georges; Gierl, Mark J; Yudkowsky, Rachel
2014-10-01
Objective structured clinical examinations (OSCEs) are used worldwide for summative examinations but often lack acceptable reliability. Research has shown that reliability of scores increases if OSCE checklists for medical students include only clinically relevant items. Also, checklists are often missing evidence-based items that high-achieving learners are more likely to use. The purpose of this study was to determine if limiting checklist items to clinically discriminating items and/or adding missing evidence-based items improved score reliability in an Internal Medicine residency OSCE. Six internists reviewed the traditional checklists of four OSCE stations classifying items as clinically discriminating or non-discriminating. Two independent reviewers augmented checklists with missing evidence-based items. We used generalizability theory to calculate overall reliability of faculty observer checklist scores from 45 first and second-year residents and predict how many 10-item stations would be required to reach a Phi coefficient of 0.8. Removing clinically non-discriminating items from the traditional checklist did not affect the number of stations (15) required to reach a Phi of 0.8 with 10 items. Focusing the checklist on only evidence-based clinically discriminating items increased test score reliability, needing 11 stations instead of 15 to reach 0.8; adding missing evidence-based clinically discriminating items to the traditional checklist modestly improved reliability (needing 14 instead of 15 stations). Checklists composed of evidence-based clinically discriminating items improved the reliability of checklist scores and reduced the number of stations needed for acceptable reliability. Educators should give preference to evidence-based items over non-evidence-based items when developing OSCE checklists.
Distribution System Reliability Analysis for Smart Grid Applications
NASA Astrophysics Data System (ADS)
Aljohani, Tawfiq Masad
Reliability of power systems is a key aspect in modern power system planning, design, and operation. The ascendance of the smart grid concept has provided high hopes of developing an intelligent network that is capable of being a self-healing grid, offering the ability to overcome the interruption problems that face the utility and cost it tens of millions in repair and loss. To address its reliability concerns, the power utilities and interested parties have spent extensive amount of time and effort to analyze and study the reliability of the generation and transmission sectors of the power grid. Only recently has attention shifted to be focused on improving the reliability of the distribution network, the connection joint between the power providers and the consumers where most of the electricity problems occur. In this work, we will examine the effect of the smart grid applications in improving the reliability of the power distribution networks. The test system used in conducting this thesis is the IEEE 34 node test feeder, released in 2003 by the Distribution System Analysis Subcommittee of the IEEE Power Engineering Society. The objective is to analyze the feeder for the optimal placement of the automatic switching devices and quantify their proper installation based on the performance of the distribution system. The measures will be the changes in the reliability system indices including SAIDI, SAIFI, and EUE. The goal is to design and simulate the effect of the installation of the Distributed Generators (DGs) on the utility's distribution system and measure the potential improvement of its reliability. The software used in this work is DISREL, which is intelligent power distribution software that is developed by General Reliability Co.
Reliability and Failure in NASA Missions: Blunders, Normal Accidents, High Reliability, Bad Luck
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2015-01-01
NASA emphasizes crew safety and system reliability but several unfortunate failures have occurred. The Apollo 1 fire was mistakenly unanticipated. After that tragedy, the Apollo program gave much more attention to safety. The Challenger accident revealed that NASA had neglected safety and that management underestimated the high risk of shuttle. Probabilistic Risk Assessment was adopted to provide more accurate failure probabilities for shuttle and other missions. NASA's "faster, better, cheaper" initiative and government procurement reform led to deliberately dismantling traditional reliability engineering. The Columbia tragedy and Mars mission failures followed. Failures can be attributed to blunders, normal accidents, or bad luck. Achieving high reliability is difficult but possible.
The implementation and use of Ada on distributed systems with high reliability requirements
NASA Technical Reports Server (NTRS)
Knight, J. C.
1988-01-01
The use and implementation of Ada were investigated in distributed environments in which reliability is the primary concern. In particular, the focus was on the possibility that a distributed system may be programmed entirely in Ada so that the individual tasks of the system are unconcerned with which processors are being executed, and that failures may occur in the software and underlying hardware. A secondary interest is in the performance of Ada systems and how that performance can be gauged reliably. Primary activities included: analysis of the original approach to recovery in distributed Ada programs using the Advanced Transport Operating System (ATOPS) example; review and assessment of the original approach which was found to be capable of improvement; development of a refined approach to recovery that was applied to the ATOPS example; and design and development of a performance assessment scheme for Ada programs based on a flexible user-driven benchmarking system.
Difficult Decisions Made Easier
NASA Technical Reports Server (NTRS)
2006-01-01
NASA missions are extremely complex and prone to sudden, catastrophic failure if equipment falters or if an unforeseen event occurs. For these reasons, NASA trains to expect the unexpected. It tests its equipment and systems in extreme conditions, and it develops risk-analysis tests to foresee any possible problems. The Space Agency recently worked with an industry partner to develop reliability analysis software capable of modeling complex, highly dynamic systems, taking into account variations in input parameters and the evolution of the system over the course of a mission. The goal of this research was multifold. It included performance and risk analyses of complex, multiphase missions, like the insertion of the Mars Reconnaissance Orbiter; reliability analyses of systems with redundant and/or repairable components; optimization analyses of system configurations with respect to cost and reliability; and sensitivity analyses to identify optimal areas for uncertainty reduction or performance enhancement.
Research and Development of Laser Diode Based Instruments for Applications in Space
NASA Technical Reports Server (NTRS)
Krainak, Michael; Abshire, James; Cornwell, Donald; Dragic, Peter; Duerksen, Gary; Switzer, Gregg
1999-01-01
Laser diode technology continues to advance at a very rapid rate due to commercial applications such as telecommunications and data storage. The advantages of laser diodes include, wide diversity of wavelengths, high efficiency, small size and weight and high reliability. Semiconductor and fiber optical-amplifiers permit efficient, high power master oscillator power amplifier (MOPA) transmitter systems. Laser diode systems which incorporate monolithic or discrete (fiber optic) gratings permit single frequency operation. We describe experimental and theoretical results of laser diode based instruments currently under development at NASA Goddard Space Flight Center including miniature lidars for measuring clouds and aerosols, water vapor and wind for Earth and planetary (Mars Lander) use.
Papadopoulou, Soultana L.; Exarchakos, Georgios; Christodoulou, Dimitrios; Theodorou, Stavroula; Beris, Alexandre; Ploumis, Avraam
2016-01-01
Introduction The Ohkuma questionnaire is a validated screening tool originally used to detect dysphagia among patients hospitalized in Japanese nursing facilities. Objective The purpose of this study is to evaluate the reliability and validity of the adapted Greek version of the Ohkuma questionnaire. Methods Following the steps for cross-cultural adaptation, we delivered the validated Ohkuma questionnaire to 70 patients (53 men, 17 women) who were either suffering from dysphagia or not. All of them completed the questionnaire a second time within a month. For all of them, we performed a bedside and VFSS study of dysphagia and asked participants to undergo a second VFSS screening, with the exception of nine individuals. Statistical analysis included measurement of internal consistency with Cronbach's α coefficient, reliability with Cohen's Kappa, Pearson's correlation coefficient and construct validity with categorical components, and One-Way Anova test. Results According to Cronbach's α coefficient (0.976) for total score, there was high internal consistency for the Ohkuma Dysphagia questionnaire. Test-retest reliability (Cohen's Kappa) ranged from 0.586 to 1.00, exhibiting acceptable stability. We also estimated the Pearson's correlation coefficient for the test-retest total score, which reached high levels (0.952; p = 0.000). The One-Way Anova test in the two measurement times showed statistically significant correlation in both measurements (p = 0.02 and p = 0.016). Conclusion The adapted Greek version of the questionnaire is valid and reliable and can be used for the screening of dysphagia in the Greek-speaking patients. PMID:28050209
Papadopoulou, Soultana L; Exarchakos, Georgios; Christodoulou, Dimitrios; Theodorou, Stavroula; Beris, Alexandre; Ploumis, Avraam
2017-01-01
Introduction The Ohkuma questionnaire is a validated screening tool originally used to detect dysphagia among patients hospitalized in Japanese nursing facilities. Objective The purpose of this study is to evaluate the reliability and validity of the adapted Greek version of the Ohkuma questionnaire. Methods Following the steps for cross-cultural adaptation, we delivered the validated Ohkuma questionnaire to 70 patients (53 men, 17 women) who were either suffering from dysphagia or not. All of them completed the questionnaire a second time within a month. For all of them, we performed a bedside and VFSS study of dysphagia and asked participants to undergo a second VFSS screening, with the exception of nine individuals. Statistical analysis included measurement of internal consistency with Cronbach's α coefficient, reliability with Cohen's Kappa, Pearson's correlation coefficient and construct validity with categorical components, and One-Way Anova test. Results According to Cronbach's α coefficient (0.976) for total score, there was high internal consistency for the Ohkuma Dysphagia questionnaire. Test-retest reliability (Cohen's Kappa) ranged from 0.586 to 1.00, exhibiting acceptable stability. We also estimated the Pearson's correlation coefficient for the test-retest total score, which reached high levels (0.952; p = 0.000). The One-Way Anova test in the two measurement times showed statistically significant correlation in both measurements ( p = 0.02 and p = 0.016). Conclusion The adapted Greek version of the questionnaire is valid and reliable and can be used for the screening of dysphagia in the Greek-speaking patients.
Amann, Michael; Pezold, Simon; Naegelin, Yvonne; Fundana, Ketut; Andělová, Michaela; Weier, Katrin; Stippich, Christoph; Kappos, Ludwig; Radue, Ernst-Wilhelm; Cattin, Philippe; Sprenger, Till
2016-07-01
Spinal cord (SC) atrophy is an important contributor to the development of disability in many neurological disorders including multiple sclerosis (MS). To assess the spinal cord atrophy in clinical trials and clinical practice, largely automated methods are needed due to the sheer amount of data. Moreover, using these methods in longitudinal trials requires them to deliver highly reliable measurements, enabling comparisons of multiple data sets of the same subject over time. We present a method for SC volumetry using 3D MRI data providing volume measurements for SC sections of fixed length and location. The segmentation combines a continuous max flow approach with SC surface reconstruction that locates the SC boundary based on image voxel intensities. Two cutting planes perpendicular to the SC centerline are determined based on predefined distances to an anatomical landmark, and the cervical SC volume (CSCV) is then calculated in-between these boundaries. The development of the method focused on its application in MRI follow-up studies; the method provides a high scan-rescan reliability, which was tested on healthy subject data. Scan-rescan reliability coefficients of variation (COV) were below 1 %, intra- and interrater COV were even lower (0.1-0.2 %). To show the applicability in longitudinal trials, 3-year follow-up data of 48 patients with a progressive course of MS were assessed. In this cohort, CSCV loss was the only significant predictor of disability progression (p = 0.02). We are, therefore, confident that our method provides a reliable tool for SC volumetry in longitudinal clinical trials.
Reliability Assessment Approach for Stirling Convertors and Generators
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Schreiber, Jeffrey G.; Zampino, Edward; Best, Timothy
2004-01-01
Stirling power conversion is being considered for use in a Radioisotope Power System for deep-space science missions because it offers a multifold increase in the conversion efficiency of heat to electric power. Quantifying the reliability of a Radioisotope Power System that utilizes Stirling power conversion technology is important in developing and demonstrating the capability for long-term success. A description of the Stirling power convertor is provided, along with a discussion about some of the key components. Ongoing efforts to understand component life, design variables at the component and system levels, related sources, and the nature of uncertainties is discussed. The requirement for reliability also is discussed, and some of the critical areas of concern are identified. A section on the objectives of the performance model development and a computation of reliability is included to highlight the goals of this effort. Also, a viable physics-based reliability plan to model the design-level variable uncertainties at the component and system levels is outlined, and potential benefits are elucidated. The plan involves the interaction of different disciplines, maintaining the physical and probabilistic correlations at all the levels, and a verification process based on rational short-term tests. In addition, both top-down and bottom-up coherency were maintained to follow the physics-based design process and mission requirements. The outlined reliability assessment approach provides guidelines to improve the design and identifies governing variables to achieve high reliability in the Stirling Radioisotope Generator design.
Evaluation of tools used to measure calcium and/or dairy consumption in children and adolescents.
Magarey, Anthea; Yaxley, Alison; Markow, Kylie; Baulderstone, Lauren; Miller, Michelle
2014-08-01
To identify and critique tools that assess Ca and/or dairy intake in children to ascertain the most accurate and reliable tools available. A systematic review of the literature was conducted using defined inclusion and exclusion criteria. Articles were included on the basis that they reported on a tool measuring Ca and/or dairy intake in children in Western countries and reported on originally developed tools or tested the validity or reliability of existing tools. Defined criteria for reporting reliability and validity properties were applied. Studies in Western countries. Children. Eighteen papers reporting on two tools that assessed dairy intake, ten that assessed Ca intake and five that assessed both dairy and Ca were identified. An examination of tool testing revealed high reliance on lower-order tests such as correlation and failure to differentiate between statistical and clinically meaningful significance. Only half of the tools were tested for reliability and results indicated that only one Ca tool and one dairy tool were reliable. Validation studies showed acceptable levels of agreement (<100 mg difference) and/or sensitivity (62-83 %) and specificity (55-77 %) in three Ca tools. With reference to the testing methodology and results, no tools were considered both valid and reliable for the assessment of dairy intake and only one tool proved valid and reliable for the assessment of Ca intake. These results clearly indicate the need for development and rigorous testing of tools to assess Ca and/or dairy intake in children and adolescents.
Saad, Karen Ruggeri; Colombo, Alexandra S; João, Silvia M Amado
2009-01-01
The purpose of this study was to investigate the reliability and validity of photogrammetry in measuring the lateral spinal inclination angles. Forty subjects (32 female and 8 males) with a mean age of 23.4 +/- 11.2 years had their scoliosis evaluated by radiographs of their trunk, determined by the Cobb angle method, and by photogrammetry. The statistical methods used included Cronbach alpha, Pearson/Spearman correlation coefficients, and regression analyses. The Cronbach alpha values showed that the photogrammetric measures showed high internal consistency, which indicated that the sample was bias free. The radiograph method showed to be more precise with intrarater reliabilities of 0.936, 0.975, and 0.945 for the thoracic, lumbar, and thoracolumbar curves, respectively, and interrater reliabilities of 0.942 and 0.879 for the angular measures of the thoracic and thoracolumbar segments, respectively. The regression analyses revealed a high determination coefficient although limited to the adjusted linear model between the radiographic and photographic measures. It was found that with more severe scoliosis, the lateral curve measures obtained with the photogrammetry were for the thoracic and lumbar regions (R = 0.619 and 0.551). The photogrammetric measures were found to be reproducible in this study and could be used as supplementary information to decrease the number of radiographs necessary for the monitoring of scoliosis.
Hoffman, Hal M; Wolfe, Frederick; Belomestnov, Pavel; Mellis, Scott J
2008-09-01
Development of an instrument for characterization of symptom patterns and severity in patients with cryopyrin-associated periodic syndromes (CAPS). Two generations of daily health assessment forms (DHAFs) were evaluated in this study. The first-generation DHAF queried 11 symptoms. Analyses of results obtained with that instrument identified five symptoms included in a revised second-generation DHAF that was tested for internal consistency and test-retest reliability. This DHAF was also assessed during the initial portion of a phase 3 clinical study of CAPS treatment. Forty-eight CAPS patients provided data for the first-generation DHAFs. Five symptoms (rash, fever, joint pain, eye redness/pain, and fatigue) were included in the revised second-generation DHAF. Symptom severity was highly variable during all study phases with as many as 89% of patients reporting at least one symptom flare, and percentages of days with flares reaching 58% during evaluation of the second-generation instrument. Mean composite key symptom scores (KSSs) computed during evaluation of the second-generation DHAF correlated well with Physician's Global Assessment of Disease Activity (r=0.91, p<0.0001) and patient reports of limitations of daily activities (r=0.68, p<0.0001). Test-retest reliability and Cronbach's alpha's were high (0.93 and 0.94, respectively) for the second-generation DHAF. Further evaluation of this DHAF during a baseline period and placebo treatment in a phase 3 clinical study of CAPS patients indicated strong correlations between baseline KSS and Physician's Global Assessment of Disease Activity. Cronbach's alpha's at baseline and test-retest reliability were also high. Potentially important study limitations include small sample size, the lack of a standard tool for CAPS symptom assessment against which to validate the DHAF, and no assessment of the instrument's responsivity to CAPS therapy. The DHAF is a new instrument that may be useful for capturing symptom patterns and severity in CAPS patients and monitoring responses to therapies for these conditions.
Wang, W J; Dong, J; Ren, Z P; Chen, B; He, W; Li, W D; Hao, Z W
2016-07-06
To evaluate the validity, reliability, and acceptability of the scale of knowledge, attitude, and behavior of lifestyle intervention in a diabetes high-risk population (HILKAB), and provide scientific evidence for its usage. By convenient sampling, we selected 406 individuals at high risk for diabetes for survey using the HILKAB. Pearson correlation coefficient, factor analysis, independent sampling, and t-test for high- and low-score groups were used to evaluate the content validity, construct validity, and discriminant validity of the scale. Reliability of the scale was evaluated by internal consistency, which included Cronbach's α coefficient, θ coefficient, Ω coefficient, and split-half reliability. Scale acceptability was evaluated by acceptance rate and completion time of the survey. In this study, 366 questionnaires (90.1%) was qnalified and the completion time was (8.62±2.79) minutes. Scores for knowledge, attitude, and behavior were 10.60±3.73, 26.56±3.58, 17.09±9.74, respectively. The scale had good face validity and content validity. The correlation coefficient of items and the dimension to which they belong was between 0.25 and 0.97, and the correlation coefficient of three dimensions and the entire scale was between 0.64 and 0.91, all with P<0.001. Factor analysis of the scale extracted eight common factors. The cumulative variance contribution rate was 65.23%, thereby reaching the 50% approved standard. Of 30 items there were 29 items with factor loadings ≥0.40, indicating the scale had good construct validity. For the high-score group, scores for knowledge, attitude, and behavior dimensions were 13.89±2.55, 29.56± 2.46, 28.05 ± 2.93, respectively, which were higher than those for the low-score group (7.67 ± 2.78, 23.89 ± 3.35, 6.25 ± 3.13); t-values were 55.14, 119.40, 95.29, respectively, with P<0.001. The scale consisted of three dimensions: knowledge, attitude, and behavior. The Cronbach's α coefficient was between 0.84 and 0.92, the θ coefficient was between 0.85 and 0.96, the Ω coefficient was between 0.90 and 0.94, and the split-half reliability was between 0.77 and 0.95, reaching the 0.70 standard letter. The validity, reliability, and acceptability of the HILKAB scale were satisfactory for use in a population at high risk of diabetes.
ERIC Educational Resources Information Center
Stringfield, Sam; Reynolds, David; Schaffer, Eugene
2016-01-01
This chapter presents data from a 15-year, mixed-methods school improvement effort. The High Reliability Schools (HRS) reform made use of previous research on school effects and on High Reliability Organizations (HROs). HROs are organizations in various parts of our cultures that are required to operate successfully "the first time, every…
Griew, Pippa; Hillsdon, Melvyn; Foster, Charlie; Coombes, Emma; Jones, Andy; Wilkinson, Paul
2013-08-23
Walking for physical activity is associated with substantial health benefits for adults. Increasingly research has focused on associations between walking behaviours and neighbourhood environments including street characteristics such as pavement availability and aesthetics. Nevertheless, objective assessment of street-level data is challenging. This research investigates the reliability of a new street characteristic audit tool designed for use with Google Street View, and assesses levels of agreement between computer-based and on-site auditing. The Forty Area STudy street VIEW (FASTVIEW) tool, a Google Street View based audit tool, was developed incorporating nine categories of street characteristics. Using the tool, desk-based audits were conducted by trained researchers across one large UK town during 2011. Both inter and intra-rater reliability were assessed. On-site street audits were also completed to test the criterion validity of the method. All reliability scores were assessed by percentage agreement and the kappa statistic. Within-rater agreement was high for each category of street characteristic (range: 66.7%-90.0%) and good to high between raters (range: 51.3%-89.1%). A high level of agreement was found between the Google Street View audits and those conducted in-person across the nine categories examined (range: 75.0%-96.7%). The audit tool was found to provide a reliable and valid measure of street characteristics. The use of Google Street View to capture street characteristic data is recommended as an efficient method that could substantially increase potential for large-scale objective data collection.
Dalen, Havard; Gundersen, Guri H; Skjetne, Kyrre; Haug, Hilde H; Kleinau, Jens O; Norekval, Tone M; Graven, Torbjorn
2015-08-01
Routine assessment of volume state by ultrasound may improve follow-up of heart failure patients. We aimed to study the feasibility and reliability of focused pocket-size ultrasound examinations of the pleural cavities and the inferior vena cava performed by nurses to assess volume state at an outpatient heart failure clinic. Ultrasound examinations were performed in 62 included heart failure patients by specialized nurses with a pocket-size imaging device (PSID). Patients were then re-examined by a cardiologist with a high-end scanner for reference within 1 h. Specialized nurses were able to obtain and interpret images from both pleural cavities and the inferior vena cava and estimate the volume status in all patients. Time consumption for focused ultrasound examination was median 5 min. In total 26 patients had any kind of pleural effusion (in 39 pleural cavities) by reference. The sensitivity, specificity, positive and negative predictive values were high, all ≥ 92%. The correlations with reference were high for all measurements, all r ≥ 0.79. Coefficients of variation for end-expiratory dimension of inferior vena cava and quantification of pleural effusion were 10.8% and 12.7%, respectively. Specialized nurses were, after a dedicated training protocol, able to obtain reliable recordings of both pleural cavities and the inferior vena cava by PSID and interpret the images in a reliable way. Implementing focused ultrasound examinations to assess volume status by nurses in an outpatient heart failure clinic may improve diagnostics, and thus improve therapy. © The European Society of Cardiology 2014.
Lombarts, Kiki M J M H; Ferguson, Andrew; Hollmann, Markus W; Malling, Bente; Arah, Onyebuchi A
2016-11-01
Given the increasing international recognition of clinical teaching as a competency and regulation of residency training, evaluation of anesthesiology faculty teaching is needed. The System for Evaluating Teaching Qualities (SETQ) Smart questionnaires were developed for assessing teaching performance of faculty in residency training programs in different countries. This study investigated (1) the structure, (2) the psychometric qualities of the new tools, and (3) the number of residents' evaluations needed per anesthesiology faculty to use the instruments reliably. Two SETQ Smart questionnaires-for faculty self-evaluation and for resident evaluation of faculty-were developed. A multicenter survey was conducted among 399 anesthesiology faculty and 430 residents in six countries. Statistical analyses included exploratory factor analysis, reliability analysis using Cronbach α, item-total scale correlations, interscale correlations, comparison of composite scales to global ratings, and generalizability analysis to assess residents' evaluations needed per faculty. In total, 240 residents completed 1,622 evaluations of 247 faculty. The SETQ Smart questionnaires revealed six teaching qualities consisting of 25 items. Cronbach α's were very high (greater than 0.95) for the overall SETQ Smart questionnaires and high (greater than 0.80) for the separate teaching qualities. Interscale correlations were all within the acceptable range of moderate correlation. Overall, questionnaire and scale scores correlated moderately to highly with the global ratings. For reliable feedback to individual faculty, three to five resident evaluations are needed. The first internationally piloted questionnaires for evaluating individual anesthesiology faculty teaching performance can be reliably, validly, and feasibly used for formative purposes in residency training.
Jeter, Pamela E.; Wang, Jiangxia; Gu, Jialiang; Barry, Michael P.; Roach, Crystal; Corson, Marilyn; Yang, Liancheng; Dagnelie, Gislin
2014-01-01
Individuals with visual impairment (VI) have irreparable damage to one of the input streams contributing to postural stability. Here, we evaluated the intra-session test-retest reliability of the Wii Balance Board (WBB) for measuring Center of Pressure (COP) magnitude and structure, i.e. approximate entropy (ApEn) in fourteen legally blind participants and 21 participants with corrected-to-normal vision. Participants completed a validated balance protocol which included four sensory conditions: double-leg standing on a firm surface with eyes open (EO-firm); a firm surface with eyes closed (EC-firm); a foam surface with EO (EO-foam); and a foam surface with EC (EC-foam). Participants performed the full balance protocol twice during the session, separated by a period of 15 minutes, to determine the intraclass correlation coefficient (ICC). Absolute reliability was determined by the standard of measurement (SEM). The minimal difference (MD) was estimated to determine clinical significance for future studies. COP measures were derived from data sent by the WBB to a laptop via Bluetooth. COP scores increased with the difficulty of sensory condition indicating WBB sensitivity (all p < 0.01). ICCs in the VI group ranged from 0.73 to 0.95, indicating high to very high correlations, and the normal group showed moderate to very high ICCs (0.62–0.94). The SEM was comparable between groups regardless of between-subject variability. The reliability of the WBB makes it practical to screen for balance impairment among VI persons. PMID:25555361
Comparison of Reliability Measures under Factor Analysis and Item Response Theory
ERIC Educational Resources Information Center
Cheng, Ying; Yuan, Ke-Hai; Liu, Cheng
2012-01-01
Reliability of test scores is one of the most pervasive psychometric concepts in measurement. Reliability coefficients based on a unifactor model for continuous indicators include maximal reliability rho and an unweighted sum score-based omega, among many others. With increasing popularity of item response theory, a parallel reliability measure pi…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1986-08-01
Significant accomplishments in fabricating cermaic components for the Department of Energy (DOE), National Aeronautics and Space Administration (NASA), and Department of Defense (DOD) advanced heat engine programs have provided evidence that the operation of ceramic parts in high-temperature engine environments is feasible. However, additional research is needed in materials and processing development, design methodology, and data base and life prediction. An assessment of needs was completed, and a five-year project plan was developed with extensive input from private industry. The objective of the project is to develop the industrial technology base required for reliable ceramics for application in advanced automotivemore » heat engines. The project approach includes determining the mechanisms controlling reliability, improving processes for fabricating existing ceramics, developing new materials with increased reliability, and testing these materials in simulated engine environments to confirm reliability. although this is a generic materials project, the focus is on structural ceramics for advanced gas turbine and diesel engines, ceramic bearings and attachments, and ceramic coatings for thermal barrier and wear applications in these engines.« less
Schneebeli, Alessandro; Egloff, Michele; Giampietro, Amelia; Clijsen, Ron; Barbero, Marco
2014-04-01
To examine intra- and interrater reliability of thickness and cross-sectional area (CSA) measurements of the supraspinatus muscle using rehabilitative ultrasound imaging (RUSI). Two physical therapists acquired b-mode images of the supraspinatus muscles in twenty-five healthy subjects. Thickness and CSA were measured. Intra- and interrater reliability were examined. Intrarater reliability for thickness was high, (ICC1.1 0.91) for rater 1 and (ICC1.1 0.92) for rater 2. Intrarater reliability for CSA was also high, (ICC1.1 0.90) for rater 1 and (ICC1.1 0.85) for rater 2. Interrater reliability for the thickness was high, (ICC3.1 0.86). For CSA, interrater reliability was moderate, (ICC3.1 0.70). Supraspinatus muscle thickness and CSA can be reliably measured by physical therapists in healthy subjects. These findings confirm that RUSI has an interesting potential for physiotherapy clinical practice, especially to assess morphometric changes in skeletal muscles. Further research is needed in subjects with shoulder disorders. Copyright © 2013 Elsevier Ltd. All rights reserved.
JCQ scale reliability and responsiveness to changes in manufacturing process.
d'Errico, Angelo; Punnett, Laura; Gold, Judith E; Gore, Rebecca
2008-02-01
The job content questionnaire (JCQ) was administered to automobile manufacturing workers in two interviews, 5 years apart. Between the two interviews, the company introduced substantial changes in production technology in some production areas. The aims were: (1) to describe the impact of these changes on self-reported psychosocial exposures, and (2) to examine test-retest reliability of the JCQ scales, taking into account changes in job assignment and, for a subset of workers, physical ergonomic exposures as assessed through field observations. The study population included 790 subjects at the first and 519 at the second interview, of whom 387 were present in both. Differences in demand and control scores between interviews were analyzed by Wilcoxon matched-pairs signed-rank test. Test-retest reliability of these scales was evaluated by the intraclass correlation coefficient (ICC) and the Spearman's rho coefficient. The introduction of more automated technology produced an overall increase in job control but did not decrease psychological demand. The reliability of the control scale was low overall but increased to an acceptable level among workers who had not changed job. The demand scale had high reliability only among workers whose physical ergonomic exposures were similar on both survey occasions. These results show that 5-year test-retest reliability of self-reported psychosocial exposures is adequate among workers whose job assignment and ergonomic exposures have remained stable over time.
Lange, Toni; Matthijs, Omer; Jain, Nitin B; Schmitt, Jochen; Lützner, Jörg; Kopkow, Christian
2017-03-01
Shoulder pain in the general population is common and to identify the aetiology of shoulder pain, history, motion and muscle testing, and physical examination tests are usually performed. The aim of this systematic review was to summarise and evaluate intrarater and inter-rater reliability of physical examination tests in the diagnosis of shoulder pathologies. A comprehensive systematic literature search was conducted using MEDLINE, EMBASE, Allied and Complementary Medicine Database (AMED) and Physiotherapy Evidence Database (PEDro) through 20 March 2015. Methodological quality was assessed using the Quality Appraisal of Reliability Studies (QAREL) tool by 2 independent reviewers. The search strategy revealed 3259 articles, of which 18 finally met the inclusion criteria. These studies evaluated the reliability of 62 test and test variations used for the specific physical examination tests for the diagnosis of shoulder pathologies. Methodological quality ranged from 2 to 7 positive criteria of the 11 items of the QAREL tool. This review identified a lack of high-quality studies evaluating inter-rater as well as intrarater reliability of specific physical examination tests for the diagnosis of shoulder pathologies. In addition, reliability measures differed between included studies hindering proper cross-study comparisons. PROSPERO CRD42014009018. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Reliability and criterion-related validity of a new repeated agility test
Makni, E; Jemni, M; Elloumi, M; Chamari, K; Nabli, MA; Padulo, J; Moalla, W
2016-01-01
The study aimed to assess the reliability and the criterion-related validity of a new repeated sprint T-test (RSTT) that includes intense multidirectional intermittent efforts. The RSTT consisted of 7 maximal repeated executions of the agility T-test with 25 s of passive recovery rest in between. Forty-five team sports players performed two RSTTs separated by 3 days to assess the reliability of best time (BT) and total time (TT) of the RSTT. The intra-class correlation coefficient analysis revealed a high relative reliability between test and retest for BT and TT (>0.90). The standard error of measurement (<0.50) showed that the RSTT has a good absolute reliability. The minimal detectable change values for BT and TT related to the RSTT were 0.09 s and 0.58 s, respectively. To check the criterion-related validity of the RSTT, players performed a repeated linear sprint (RLS) and a repeated sprint with changes of direction (RSCD). Significant correlations between the BT and TT of the RLS, RSCD and RSTT were observed (p<0.001). The RSTT is, therefore, a reliable and valid measure of the intermittent repeated sprint agility performance. As this ability is required in all team sports, it is suggested that team sports coaches, fitness coaches and sports scientists consider this test in their training follow-up. PMID:27274109
Modified Core Wash Cytology: A reliable same day biopsy result for breast clinics.
Bulte, J P; Wauters, C A P; Duijm, L E M; de Wilt, J H W; Strobbe, L J A
2016-12-01
Fine Needle Aspiration Biopsy (FNAB), Core Needle biopsy (CNB) and hybrid techniques including Core Wash Cytology (CWC) are available for same-day diagnosis in breast lesions. In CWC a washing of the biopsy core is processed for a provisional cytological diagnosis, after which the core is processed like a regular CNB. This study focuses on the reliability of CWC in daily practice. All consecutive CWC procedures performed in a referral breast centre between May 2009 and May 2012 were reviewed, correlating CWC results with the CNB result, definitive diagnosis after surgical resection and/or follow-up. Symptomatic as well as screen-detected lesions, undergoing CNB were included. 1253 CWC procedures were performed. Definitive histology showed 849 (68%) malignant and 404 (32%) benign lesions. 80% of CWC procedures yielded a conclusive diagnosis: this percentage was higher amongst malignant lesions and lower for benign lesions: 89% and 62% respectively. Sensitivity and specificity of a conclusive CWC result were respectively 98.3% and 90.4%. The eventual incidence of malignancy in the cytological 'atypical' group (5%) was similar to the cytological 'benign' group (6%). CWC can be used to make a reliable provisional diagnosis of breast lesions within the hour. The high probability of conclusive results in malignant lesions makes CWC well suited for high risk populations. Copyright © 2016 Elsevier Ltd, BASO ~ the Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.
Ng, Shamay S. M.; Ng, Gabriel Y. F.
2014-01-01
Objectives. To (1) translate and culturally adapt the English version Community Integration Measure into Chinese (Cantonese), (2) report the results of initial validation of the Chinese (Cantonese) version of CIM (CIM-C) including the content validity, internal consistency, test-retest reliability, and factor structure of CIM-C for use in stroke survivors in a Chinese community setting, and (3) investigate the level of community integration of stroke survivors living in Hong Kong. Design. Cross-sectional study. Setting. University-based rehabilitation centre. Participants. 62 (n = 62) subjects with chronic stroke. Methods. The CIM-C was produced after forward-backward translation, expert panel review, and pretesting. 25 (n = 25) of the same subjects were reassessed after a 1-week interval. Results. The items of the CIM-C demonstrated high internal consistency with a Cronbach's α of 0.84. The CIM-C showed good test-retest reliability with an intraclass correlation coefficient (ICC) of 0.84 (95% confidence interval, 0.64–0.93). A 3-factor structure of the CIM-C including “relationship and engagement,” “sense of knowing,” and “independent living,” was consistent with the original theoretical model. Hong Kong stroke survivors revealed a high level of community integration as measured by the CIM-C (mean (SD): 43.48 (5.79)). Conclusions. The CIM-C is a valid and reliable measure for clinical use. PMID:24995317
Baker, Elizabeth A; Ledford, Cynthia H; Fogg, Louis; Way, David P; Park, Yoon Soo
2015-01-01
Construct: Clinical skills are used in the care of patients, including reporting, diagnostic reasoning, and decision-making skills. Written comprehensive new patient admission notes (H&Ps) are a ubiquitous part of student education but are underutilized in the assessment of clinical skills. The interpretive summary, differential diagnosis, explanation of reasoning, and alternatives (IDEA) assessment tool was developed to assess students' clinical skills using written comprehensive new patient admission notes. The validity evidence for assessment of clinical skills using clinical documentation following authentic patient encounters has not been well documented. Diagnostic justification tools and postencounter notes are described in the literature (1,2) but are based on standardized patient encounters. To our knowledge, the IDEA assessment tool is the first published tool that uses medical students' H&Ps to rate students' clinical skills. The IDEA assessment tool is a 15-item instrument that asks evaluators to rate students' reporting, diagnostic reasoning, and decision-making skills based on medical students' new patient admission notes. This study presents validity evidence in support of the IDEA assessment tool using Messick's unified framework, including content (theoretical framework), response process (interrater reliability), internal structure (factor analysis and internal-consistency reliability), and relationship to other variables. Validity evidence is based on results from four studies conducted between 2010 and 2013. First, the factor analysis (2010, n = 216) yielded a three-factor solution, measuring patient story, IDEA, and completeness, with reliabilities of .79, .88, and .79, respectively. Second, an initial interrater reliability study (2010) involving two raters demonstrated fair to moderate consensus (κ = .21-.56, ρ =.42-.79). Third, a second interrater reliability study (2011) with 22 trained raters also demonstrated fair to moderate agreement (intraclass correlations [ICCs] = .29-.67). There was moderate reliability for all three skill domains, including reporting skills (ICC = .53), diagnostic reasoning skills (ICC = .64), and decision-making skills (ICC = .63). Fourth, there was a significant correlation between IDEA rating scores (2010-2013) and final Internal Medicine clerkship grades (r = .24), 95% confidence interval (CI) [.15, .33]. The IDEA assessment tool is a novel tool with validity evidence to support its use in the assessment of students' reporting, diagnostic reasoning, and decision-making skills. The moderate reliability achieved supports formative or lower stakes summative uses rather than high-stakes summative judgments.
NASA Technical Reports Server (NTRS)
Migneault, G. E.
1979-01-01
Emulation techniques are proposed as a solution to a difficulty arising in the analysis of the reliability of highly reliable computer systems for future commercial aircraft. The difficulty, viz., the lack of credible precision in reliability estimates obtained by analytical modeling techniques are established. The difficulty is shown to be an unavoidable consequence of: (1) a high reliability requirement so demanding as to make system evaluation by use testing infeasible, (2) a complex system design technique, fault tolerance, (3) system reliability dominated by errors due to flaws in the system definition, and (4) elaborate analytical modeling techniques whose precision outputs are quite sensitive to errors of approximation in their input data. The technique of emulation is described, indicating how its input is a simple description of the logical structure of a system and its output is the consequent behavior. The use of emulation techniques is discussed for pseudo-testing systems to evaluate bounds on the parameter values needed for the analytical techniques.
A self-learning camera for the validation of highly variable and pseudorandom patterns
NASA Astrophysics Data System (ADS)
Kelley, Michael
2004-05-01
Reliable and productive manufacturing operations have depended on people to quickly detect and solve problems whenever they appear. Over the last 20 years, more and more manufacturing operations have embraced machine vision systems to increase productivity, reliability and cost-effectiveness, including reducing the number of human operators required. Although machine vision technology has long been capable of solving simple problems, it has still not been broadly implemented. The reason is that until now, no machine vision system has been designed to meet the unique demands of complicated pattern recognition. The ZiCAM family was specifically developed to be the first practical hardware to meet these needs. To be able to address non-traditional applications, the machine vision industry must include smart camera technology that meets its users" demands for lower costs, better performance and the ability to address applications of irregular lighting, patterns and color. The next-generation smart cameras will need to evolve as a fundamentally different kind of sensor, with new technology that behaves like a human but performs like a computer. Neural network based systems, coupled with self-taught, n-space, non-linear modeling, promises to be the enabler of the next generation of machine vision equipment. Image processing technology is now available that enables a system to match an operator"s subjectivity. A Zero-Instruction-Set-Computer (ZISC) powered smart camera allows high-speed fuzzy-logic processing, without the need for computer programming. This can address applications of validating highly variable and pseudo-random patterns. A hardware-based implementation of a neural network, Zero-Instruction-Set-Computer, enables a vision system to "think" and "inspect" like a human, with the speed and reliability of a machine.
Soler, Zachary M.; Hyer, J. Madison; Karnezis, Tom T.; Schlosser, Rodney J.
2015-01-01
Introduction Olfactory loss affects a majority of patients with chronic rhinosinusitis (CRS). Traditional objective measures of disease severity, including endoscopy scales, focus upon the paranasal sinuses and often have weak correlation to olfaction. Methods Adults with CRS were prospectively evaluated by blinded reviewers with a novel Olfactory Cleft Endoscopy Scale (OCES) that evaluated discharge, polyps, edema, crusting and scarring of the olfactory cleft. Objective olfactory function was assessed using “Sniffin’ Sticks testing, including composite threshold-discrimination-identification (TDI) scores. Olfactory-specific quality-of-life was evaluated using the short modified version of the Questionnaire of Olfactory Disorders (QOD-NS). Inter- and intra-rater reliability was assessed among 3 reviewers for OCES grading. Multivariate linear regression was then used to test associations between OCES scores and measures of olfaction, controlling for potential confounding factors. Results The OCES score was evaluated in 38 patients and had a high overall reliability (ICC=0.92; 95% CI: 0.91–0.96). The OCES significantly correlated with objective olfaction as measured by TDI score (p<0.001), with TDI score falling by 1.13 points for every 1 point increase in OCES score. Similar significant associations were found for threshold, discrimination, and identification scores (p<0.003 for all) after controlling for age, gender, race, and reviewer/review. The OCES was also highly associated with patient-reported QOD-NS scores (p=0.009). Conclusion A novel olfactory cleft endoscopy scale shows high reliability and correlates with both objective and patient-reported olfaction in patients with CRS. Further studies to determine prognostic value and responsiveness to change are warranted. PMID:26718315
Doherty, S; Oram, S; Siriwardhana, C; Abas, M
2016-05-01
Trafficking is a global human rights violation with multiple and complex mental health consequences. Valid and reliable mental health assessment tools are needed to inform health-care provision. We reviewed mental health assessment tools used in research with men and women trafficked for sexual and labour exploitation. We searched nine electronic databases (PsycINFO, Ovid Medline, PubMed, Embase, Assia, the Web of Science, Global Health, Google Scholar, and Open Grey) and hand-searched the reference lists of relevant identified studies. Seven studies were included in this Review. Six of the studies screened for post-traumatic stress disorder, depression, and anxiety; one study screened for harmful use or abuse of alcohol and used a diagnostic tool to assess post-traumatic stress disorder, depression, and anxiety. Two studies included men in their sample population. Although the reported prevalence of mental health problems was high, little information was provided about the validity, reliability, and cultural appropriateness of assessment tools. Further research is needed to determine which assessment tools are culturally appropriate, valid, and reliable for trafficked people. Copyright © 2016 Elsevier Ltd. All rights reserved.
A screening mammography program. Staying alive and making it work.
Monsees, B S; Destouet, J M
1992-01-01
The success of a mammography screening program requires thorough planning. A dependably high volume and a streamlined efficient operation are essential to survival of the program. Factors that warrant consideration prior to designing such a program include the following: Distinction between screening and diagnostic mammography examinations. Selection of a site that will meet the needs of the community and yet provide a consistently high volume. Low examination cost for screening mammography coupled with a detailed financial analysis and reappraisal on an ongoing basis. A customized marketing program that incorporates methods to increase awareness, compliance, and utilization by women and referring physicians. Well-trained, efficient, and dedicated personnel. An operation that is designed for rapid throughput and expeditious patient flow. An efficient plan for film handling, interpretation, reporting, and storage. Timely communication of examination results. A reliable mechanism for follow-up evaluation and outcome data collection. Establishment of a consistent and reliable quality assurance program and the production of high quality mammograms.
Flores-Herrera, Patricio; Arredondo-Zelada, Oscar; Marshall, Sergio H; Gómez, Fernando A
2018-06-01
Piscirickettsia salmonis is a highly aggressive facultative intracellular bacterium that challenges the sustainability of Chilean salmon production. Due to the limited knowledge of its biology, there is a need to identify key molecular markers that could help define the pathogenic potential of this bacterium. We think a model system should be implemented that efficiently evaluates the expression of putative bacterial markers by using validated, stable, and highly specific housekeeping genes to properly select target genes, which could lead to identifying those responsible for infection and disease induction in naturally infected fish. Here, we selected a set of validated reference or housekeeping genes for RT-qPCR expression analyses of P. salmonis under different growth and stress conditions, including an in vitro infection kinetic. After a thorough screening, we selected sdhA as the most reliable housekeeping gene able to represent stable and highly specific host reference genes for RT-qPCR-driven P. salmonis analysis. Copyright © 2018. Published by Elsevier B.V.
Zhao, Ming-liang; Liu, Guo-long; Sui, Jian-feng; Ruan, Huai-zhen; Xiong, Ying
2007-05-01
To develop simple but reliable intracellular labelling method for high-resolution visualization of the fine structure of single neurons in brain slice with thickness of 500 microm. Biocytin was introduced into neurons in 500 microm-thickness brain slices while blind whole cell recording. Following processed for histochemistry using the avidin-biotin-complex method, stained slices were mounted in glycerol on special glass slides. Labelled cells were digital photomicrographed every 30 microm and reconstructed with Adobe Photoshop software. After histochemistry, limited background staining was produced. The resolution was so high that fine structure, including branching, termination of individual axons and even spines of neurons could be identified in exquisite detail with optic microscope. With the help of software, the neurons of interest could be reconstructed from a stack of photomicrographs. The modified method provides an easy and reliable approach to revealing the detailed morphological properties of single neurons in 500 microm-thickness brain slice. Without requisition of special equipment, it is suited to be broadly applied.
Reliability and validity of the Safe Routes to school parent and student surveys
2011-01-01
Background The purpose of this study is to assess the reliability and validity of the U.S. National Center for Safe Routes to School's in-class student travel tallies and written parent surveys. Over 65,000 tallies and 374,000 parent surveys have been completed, but no published studies have examined their measurement properties. Methods Students and parents from two Charlotte, NC (USA) elementary schools participated. Tallies were conducted on two consecutive days using a hand-raising protocol; on day two students were also asked to recall the previous days' travel. The recall from day two was compared with day one to assess 24-hour test-retest reliability. Convergent validity was assessed by comparing parent-reports of students' travel mode with student-reports of travel mode. Two-week test-retest reliability of the parent survey was assessed by comparing within-parent responses. Reliability and validity were assessed using kappa statistics. Results A total of 542 students participated in the in-class student travel tally reliability assessment and 262 parent-student dyads participated in the validity assessment. Reliability was high for travel to and from school (kappa > 0.8); convergent validity was lower but still high (kappa > 0.75). There were no differences by student grade level. Two-week test-retest reliability of the parent survey (n = 112) ranged from moderate to very high for objective questions on travel mode and travel times (kappa range: 0.62 - 0.97) but was substantially lower for subjective assessments of barriers to walking to school (kappa range: 0.31 - 0.76). Conclusions The student in-class student travel tally exhibited high reliability and validity at all elementary grades. The parent survey had high reliability on questions related to student travel mode, but lower reliability for attitudinal questions identifying barriers to walking to school. Parent survey design should be improved so that responses clearly indicate issues that influence parental decision making in regards to their children's mode of travel to school. PMID:21651794
NASA Astrophysics Data System (ADS)
Filatov, Alexei Vladimirovich
2002-09-01
Using electromagnetic forces to suspend rotating objects (rotors) without mechanical contact is often an appealing technical solution. Magnetic suspensions are typically required to have adequate load capacity and stiffness, and low rotational loss. Other desired features include low price, high reliability and manufacturability. With recent advances in permanent-magnet materials, the required forces can often be obtained by simply using the interaction between permanent magnets. While a magnetic bearing based entirely on permanent magnets could be expected to be inexpensive, reliable and easy to manufacture, a fundamental physical principle known as Earnshaw's theorem maintains that this type of suspension cannot be statically stable. Therefore, some other physical mechanisms must be included. One such mechanism employs the interaction between a conductor and a nonuniform magnetic field in relative motion. Its advantages include simplicity, reliability, wide range of operating temperature and system autonomy (no external wiring and power supplies are required). The disadvantages of the earlier embodiments were high rotational loss, low stiffness and load capacity. This dissertation proposes a novel type of magnetic bearing stabilized by the field-conductor interaction. One of the advantages of this bearing is that no electric field, E, develops in the conductor during the rotor rotation when the system is in no-load equilibrium. Because of this we refer to it as the Null-E Bearing. Null-E Bearings have potential for lower rotational loss and higher load capacity and stiffness than other bearings utilizing the field-conductor interaction. Their performance is highly insensitive to manufacturing inaccuracies. The Null-E Bearing in its basic form can be augmented with supplementary electronics to improve its performance. Depending on the degree of the electronics involvement, a variety of magnetic bearings can be developed ranging from a completely passive to an active magnetic bearing of a novel type. This dissertation contains theoretical analysis of the Null-E Bearing operation, including derivation of the stability conditions and estimation of some of the rotational losses. The validity of the theoretical conclusions has been demonstrated by building and testing a prototype in which non-contact suspension of a 3.2-kg rotor is achieved at spin speeds above 18 Hz.
Hill, Jonathan C; Kang, Sujin; Benedetto, Elena; Myers, Helen; Blackburn, Steven; Smith, Stephanie; Hay, Elaine; Rees, Jonathan; Beard, David; Glyn-Jones, Sion; Barker, Karen; Ellis, Benjamin; Fitzpatrick, Ray; Price, Andrew
2016-01-01
Objectives Current musculoskeletal outcome tools are fragmented across different healthcare settings and conditions. Our objectives were to develop and validate a single musculoskeletal outcome measure for use throughout the pathway and patients with different musculoskeletal conditions: the Arthritis Research UK Musculoskeletal Health Questionnaire (MSK-HQ). Setting A consensus workshop with stakeholders from across the musculoskeletal community, workshops and individual interviews with a broad mix of musculoskeletal patients identified and prioritised outcomes for MSK-HQ inclusion. Initial psychometric validation was conducted in four cohorts from community physiotherapy, and secondary care orthopaedic hip, knee and shoulder clinics. Participants Stakeholders (n=29) included primary care, physiotherapy, orthopaedic and rheumatology patients (n=8); general practitioners, physiotherapists, orthopaedists, rheumatologists and pain specialists (n=7), patient and professional national body representatives (n=10), and researchers (n=4). The four validation cohorts included 570 participants (n=210 physiotherapy, n=150 hip, n=150 knee, n=60 shoulder patients). Outcome measures Outcomes included the MSK-HQ's acceptability, feasibility, comprehension, readability and responder burden. The validation cohort outcomes were the MSK-HQ's completion rate, test–retest reliability and convergent validity with reference standards (EQ-5D-5L, Oxford Hip, Knee, Shoulder Scores, and the Keele MSK-PROM). Results Musculoskeletal domains prioritised were pain severity, physical function, work interference, social interference, sleep, fatigue, emotional health, physical activity, independence, understanding, confidence to self-manage and overall impact. Patients reported MSK-HQ items to be ‘highly relevant’ and ‘easy to understand’. Completion rates were high (94.2%), with scores normally distributed, and no floor/ceiling effects. Test–retest reliability was excellent, and convergent validity was strong (correlations 0.81–0.88). Conclusions A new musculoskeletal outcome measure has been developed through a coproduction process with patients to capture prioritised outcomes for use throughout the pathway and with different musculoskeletal conditions. Four validation cohorts found that the MSK-HQ had high completion rates, excellent test–retest reliability and strong convergent validity with reference standards. Further validation studies are ongoing, including a cohort with rheumatoid/inflammatory arthritis. PMID:27496243
Fujii, Mami N.; Ishikawa, Yasuaki; Miwa, Kazumoto; Okada, Hiromi; Uraoka, Yukiharu; Ono, Shimpei
2015-01-01
The use of indium–gallium–zinc oxide (IGZO) has paved the way for high-resolution uniform displays or integrated circuits with transparent and flexible devices. However, achieving highly reliable devices that use IGZO for low-temperature processes remains a technological challenge. We propose the use of IGZO thin-film transistors (TFTs) with an ionic-liquid gate dielectric in order to achieve high-density carrier-accumulated IGZO TFTs with high reliability, and we discuss a distinctive mechanism for the degradation of this organic–inorganic hybrid device under long-term electrical stress. Our results demonstrated that an ionic liquid or gel gate dielectric provides highly reliable and low-voltage operation with IGZO TFTs. Furthermore, high-density carrier accumulation helps improve the TFT characteristics and reliability, and it is highly relevant to the electronic phase control of oxide materials and the degradation mechanism for organic–inorganic hybrid devices. PMID:26677773
Fujii, Mami N; Ishikawa, Yasuaki; Miwa, Kazumoto; Okada, Hiromi; Uraoka, Yukiharu; Ono, Shimpei
2015-12-18
The use of indium-gallium-zinc oxide (IGZO) has paved the way for high-resolution uniform displays or integrated circuits with transparent and flexible devices. However, achieving highly reliable devices that use IGZO for low-temperature processes remains a technological challenge. We propose the use of IGZO thin-film transistors (TFTs) with an ionic-liquid gate dielectric in order to achieve high-density carrier-accumulated IGZO TFTs with high reliability, and we discuss a distinctive mechanism for the degradation of this organic-inorganic hybrid device under long-term electrical stress. Our results demonstrated that an ionic liquid or gel gate dielectric provides highly reliable and low-voltage operation with IGZO TFTs. Furthermore, high-density carrier accumulation helps improve the TFT characteristics and reliability, and it is highly relevant to the electronic phase control of oxide materials and the degradation mechanism for organic-inorganic hybrid devices.
Gray, Vicki L; Ivanova, Tanya D; Garland, S Jayne
2014-01-01
Knowing the reliability of the center of pressure (COP) is important for interpreting balance deficits post-stroke, especially when the balance deficits can necessitate the use of short duration trials. The novel aspect of this reliability study was to examine the center of pressure measures using two adjacent force platforms between and within sessions in stroke and controls. After stroke, it is important to understand the contribution of the paretic and non-paretic leg to the motor control of standing balance. Because there is a considerable body of knowledge on COP reliability on a single platform, we chose to examine reliability using two adjacent platforms which has not been examined previously in stroke. Twenty participants post-stroke and 22 controls performed an arm raise, load drop and quiet stance balance task while standing on two adjacent force platforms, on two separate days. Intraclass correlations coefficient (ICC2,1) and percentage standard error of measurement (SEM%) were calculated for COP velocity, ellipse area, anterior-posterior (AP) displacement, and medial-lateral (ML) displacement. Between sessions, COP velocity was the most reliable with high ICCs and low SEM% across groups and tasks and ellipse area was less reliable with low ICCs across groups and tasks. COP measures were less reliable during the arm raise than load drop post-stroke. Within session reliability was high for COP velocity and ML displacement requiring no more than six trials across tasks. The COP velocity was the most reliable measure with high ICCs between sessions and the high reliability was achieved with fewer trials in both groups in a single session. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Van de Casteele, J.; Bettiati, M.; Laruelle, F.; Cargemel, V.; Pagnod-Rossiaux, P.; Garabedian, P.; Raymond, L.; Laffitte, D.; Fromy, S.; Chambonnet, D.; Hirtz, J. P.
2008-02-01
We demonstrate very high reliability level on 980-1060nm high-power single-mode lasers through multi-cell tests. First, we show how our chip design and technology enables high reliability levels. Then, we aged 758 devices during 9500 hours among 6 cells with high current (0.8A-1.2A) and high submount temperature (65°C-105°C) for the reliability demonstration. Sudden catastrophic failure is the main degradation mechanism observed. A statistical failure rate model gives an Arrhenius thermal activation energy of 0.51eV and a power law forward current acceleration factor of 5.9. For high-power submarine applications (360mW pump module output optical power), this model exhibits a failure rate as low as 9 FIT at 13°C, while ultra-high power terrestrial modules (600mW) lie below 220 FIT at 25°C. Wear-out phenomena is observed only for very high current level without any reliability impact under 1.1A. For the 1060nm chip, step-stress tests were performed and a set of devices were aged during more than 2000 hours in different stress conditions. First results are in accordance with 980nm product with more than 100khours estimated MTTF. These reliability and performance features of 980-1060nm laser diodes will make high-power single-mode emitters the best choice for a number of telecommunication and industrial applications in the next few years.
Test data from small solid propellant rocket motor plume measurements (FA-21)
NASA Technical Reports Server (NTRS)
Hair, L. M.; Somers, R. E.
1976-01-01
A program is described for obtaining a reliable, parametric set of measurements in the exhaust plumes of solid propellant rocket motors. Plume measurements included pressures, temperatures, forces, heat transfer rates, particle sampling, and high-speed movies. Approximately 210,000 digital data points and 15,000 movie frames were acquired. Measurements were made at points in the plumes via rake-mounted probes, and on the surface of a large plate impinged by the exhaust plume. Parametric variations were made in pressure altitude, propellant aluminum loading, impinged plate incidence angle and distance from nozzle exit to plate or rake. Reliability was incorporated by continual use of repeat runs. The test setup of the various hardware items is described along with an account of test procedures. Test results and data accuracy are discussed. Format of the data presentation is detailed. Complete data are included in the appendix.
Fault-tolerant clock synchronization validation methodology. [in computer systems
NASA Technical Reports Server (NTRS)
Butler, Ricky W.; Palumbo, Daniel L.; Johnson, Sally C.
1987-01-01
A validation method for the synchronization subsystem of a fault-tolerant computer system is presented. The high reliability requirement of flight-crucial systems precludes the use of most traditional validation methods. The method presented utilizes formal design proof to uncover design and coding errors and experimentation to validate the assumptions of the design proof. The experimental method is described and illustrated by validating the clock synchronization system of the Software Implemented Fault Tolerance computer. The design proof of the algorithm includes a theorem that defines the maximum skew between any two nonfaulty clocks in the system in terms of specific system parameters. Most of these parameters are deterministic. One crucial parameter is the upper bound on the clock read error, which is stochastic. The probability that this upper bound is exceeded is calculated from data obtained by the measurement of system parameters. This probability is then included in a detailed reliability analysis of the system.
Spacesuit mobility knee joints
NASA Technical Reports Server (NTRS)
Vykukal, H. C. (Inventor)
1979-01-01
Pressure suit mobility joints are for use in interconnecting adjacent segments of an hermetically sealed spacesuit in which low torques, low leakage and a high degree of reliability are required. Each of the joints is a special purpose joint characterized by substantially constant volume and low torque characteristics and includes linkages which restrain the joint from longitudinal distension and includes a flexible, substantially impermeable diaphragm of tubular configuration spanning the distance between pivotally supported annuli. The diaphragms of selected joints include rolling convolutions for balancing the joints, while various joints include wedge-shaped sections which enhance the range of motion for the joints.
ERIC Educational Resources Information Center
Park, Bitnara Jasmine; Irvin, P. Shawn; Lai, Cheng-Fei; Alonzo, Julie; Tindal, Gerald
2012-01-01
In this technical report, we present the results of a reliability study of the fifth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…
ERIC Educational Resources Information Center
Lai, Cheng-Fei; Irvin, P. Shawn; Alonzo, Julie; Park, Bitnara Jasmine; Tindal, Gerald
2012-01-01
In this technical report, we present the results of a reliability study of the second-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…
ERIC Educational Resources Information Center
Park, Bitnara Jasmine; Irvin, P. Shawn; Alonzo, Julie; Lai, Cheng-Fei; Tindal, Gerald
2012-01-01
In this technical report, we present the results of a reliability study of the fourth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…
ERIC Educational Resources Information Center
Irvin, P. Shawn; Alonzo, Julie; Park, Bitnara Jasmine; Lai, Cheng-Fei; Tindal, Gerald
2012-01-01
In this technical report, we present the results of a reliability study of the sixth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…
ERIC Educational Resources Information Center
Irvin, P. Shawn; Alonzo, Julie; Lai, Cheng-Fei; Park, Bitnara Jasmine; Tindal, Gerald
2012-01-01
In this technical report, we present the results of a reliability study of the seventh-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…
ERIC Educational Resources Information Center
Lai, Cheng-Fei; Irvin, P. Shawn; Park, Bitnara Jasmine; Alonzo, Julie; Tindal, Gerald
2012-01-01
In this technical report, we present the results of a reliability study of the third-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…
Measuring metacognitive ability based on science literacy in dynamic electricity topic
NASA Astrophysics Data System (ADS)
Warni; Sunyono; Rosidin
2018-01-01
This study aims to produce an instrument of metacognition ability assessment based on science literacy on theoretically and empirically feasible dynamic electrical material. The feasibility of the assessment instrument includes theoretical validity on material, construction, and language aspects, as well as empirical validity, reliability, difficulty, distinguishing, and distractor indices. The development of assessment instruments refers to the Dick and Carey development model which includes the preliminary study stage, initial product development, validation and revision, and piloting. The instrument was tested to 32 students of class IX in SMP Negeri 20 Bandar Lampung, using the design of One Group Pretest-Postest Design. The result shows that the metacognition ability assessment instrument based on science literacy is feasible theoretically with theoretical validity percentage of 95.44% and empirical validity of 43.75% for the high category, 43.75% for the medium category, and 12.50 % for low category questions; Reliability of assessment instruments of 0.83 high categories; Difficulty level of difficult item is about 31.25% and medium category is equal to 68.75%. Item that has very good distinguishing power is 12.50%, 62.50% for good stage, and medium category is 25.00%; As well as the duplexing function on a matter of multiple choice is 80.00% including good category and 20.00% for medium category.
Lindsley, Kristina; Li, Tianjing; Ssemanda, Elizabeth; Virgili, Gianni; Dickersin, Kay
2016-01-01
Topic Are existing systematic reviews of interventions for age-related macular degeneration incorporated into clinical practice guidelines? Clinical relevance High-quality systematic reviews should be used to underpin evidence-based clinical practice guidelines and clinical care. We have examined the reliability of systematic reviews of interventions for age-related macular degeneration (AMD) and described the main findings of reliable reviews in relation to clinical practice guidelines. Methods Eligible publications are systematic reviews of the effectiveness of treatment interventions for AMD. We searched a database of systematic reviews in eyes and vision and employed no language or date restrictions; the database is up-to-date as of May 6, 2014. Two authors independently screened records for eligibility and abstracted and assessed the characteristics and methods of each review. We classified reviews as “reliable” when they reported eligibility criteria, comprehensive searches, appraisal of methodological quality of included studies, appropriate statistical methods for meta-analysis, and conclusions based on results. We mapped treatment recommendations from the American Academy of Ophthalmology Preferred Practice Patterns (AAO PPP) for AMD to the identified systematic reviews and assessed whether any reliable systematic review was cited or could have been cited to support each treatment recommendation. Results Of 1,570 systematic reviews in our database, 47 met our inclusion criteria. Most of the systematic reviews targeted neovascular AMD and investigated anti-vascular endothelial growth factor (anti-VEGF) interventions, dietary supplements or photodynamic therapy. We classified over two-thirds (33/47) of the reports as reliable. The quality of reporting varied, with criteria for reliable reporting met more often for Cochrane reviews and for reviews whose authors disclosed conflicts of interest. Although most systematic reviews were reliable, anti-VEGF agents and photodynamic therapy were the only interventions identified as effective by reliable reviews. Of 35 treatment recommendations extracted from the AAO PPP, 15 could have been supported with reliable systematic reviews; however, only one recommendation had an accompanying intervention systematic review citation, which we assessed as a reliable systematic review. No reliable systematic review was identified for 20 treatment recommendations, highlighting areas of evidence gaps. Conclusions For AMD, reliable systematic reviews exist for many treatment recommendations in the AAO PPP and should be used to support these recommendations. We also identified areas where no high-level evidence exists. Mapping clinical practice guidelines to existing systematic reviews is one way to highlight areas where evidence generation or evidence synthesis is either available or needed. PMID:26804762
High day-to-day reliability in lower leg volume measured by water displacement.
Pasley, Jeffrey D; O'Connor, Patrick J
2008-07-01
The day-to-day reliability of lower leg volume is poorly documented. This investigation determined the day-to-day reliability of lower leg volume (soleus and gastrocnemius) measured using water displacement. Thirty young adults (15 men and 15 women) had their right lower leg volume measured by water displacement on five separate occasions. The participants performed normal activities of daily living and were measured at the same time of day after being seated for 30 min. The results revealed a high day-to-day reliability for lower leg volume. The mean percentage change in lower leg volume across days compared to day 1 ranged between 0 and 0.37%. The mean within subjects coefficient of variation in lower leg volume was 0.72% and the coefficient of variation for the entire sample across days ranged from 5.66 to 6.32%. A two way mixed model intraclass correlation (30 subjects x 5 days) showed that the lower leg volume measurement was highly reliable (ICC = 0.972). Foot and total lower leg volumes showed similarly high reliability. Water displacement offers a cost effective and reliable solution for the measurement of lower leg edema across days.
Brøndum, R F; Su, G; Janss, L; Sahana, G; Guldbrandtsen, B; Boichard, D; Lund, M S
2015-06-01
This study investigated the effect on the reliability of genomic prediction when a small number of significant variants from single marker analysis based on whole genome sequence data were added to the regular 54k single nucleotide polymorphism (SNP) array data. The extra markers were selected with the aim of augmenting the custom low-density Illumina BovineLD SNP chip (San Diego, CA) used in the Nordic countries. The single-marker analysis was done breed-wise on all 16 index traits included in the breeding goals for Nordic Holstein, Danish Jersey, and Nordic Red cattle plus the total merit index itself. Depending on the trait's economic weight, 15, 10, or 5 quantitative trait loci (QTL) were selected per trait per breed and 3 to 5 markers were selected to tag each QTL. After removing duplicate markers (same marker selected for more than one trait or breed) and filtering for high pairwise linkage disequilibrium and assaying performance on the array, a total of 1,623 QTL markers were selected for inclusion on the custom chip. Genomic prediction analyses were performed for Nordic and French Holstein and Nordic Red animals using either a genomic BLUP or a Bayesian variable selection model. When using the genomic BLUP model including the QTL markers in the analysis, reliability was increased by up to 4 percentage points for production traits in Nordic Holstein animals, up to 3 percentage points for Nordic Reds, and up to 5 percentage points for French Holstein. Smaller gains of up to 1 percentage point was observed for mastitis, but only a 0.5 percentage point increase was seen for fertility. When using a Bayesian model accuracies were generally higher with only 54k data compared with the genomic BLUP approach, but increases in reliability were relatively smaller when QTL markers were included. Results from this study indicate that the reliability of genomic prediction can be increased by including markers significant in genome-wide association studies on whole genome sequence data alongside the 54k SNP set. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Reliability and Validity of a Scale for Rating Memory Impairment in Hospitalized Amnesiacs.
ERIC Educational Resources Information Center
Knight, Robert G.; Godfrey, Hamish P. D.
1984-01-01
Investigated the reliability and concurrent validity of the Inpatient Memory Impairment Scale (IMIS), using a group of memory-impaired chronic alcoholic and Korsakoff patients (N=20). Analysis revealed that the IMIS had a high degree of internal consistency and that interrater reliability is also high. (LLL)
Performance and Reliability of Bonded Interfaces for High-Temperature Packaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeVoto, Douglas
2016-06-08
This is a technical review of the DOE VTO EDT project EDT063, Performance and Reliability of Bonded Interfaces for High-Temperature Packaging. A procedure for analyzing the reliability of sintered-silver through experimental thermal cycling and crack propagation modeling has been outlined and results have been presented.
Liu, Xiaoli; Dai, Long; Chen, Bo; Feng, Nongping; Wu, Qianhui; Lin, Yonghai; Zhang, Lan; Tan, Dong; Zhang, Jinhua; Tu, Huijuan; Li, Changfeng; Wang, Wenjuan
2016-01-01
To evaluate the validity and reliability of Diabetes Self-management Knowledge, Attitude, and Behavior Assessment Scale (DSKAB). We selected 460 patients with diabetes in the community, used the scale which was after two rounds of the Delphi method and pilot study. Investigators surveyed the patients by the way of face to face. by draw lots, we selected 25 community diabetes randomly for repeating investigations after one week. The validity analyses included face validity, content validity, construct validity and discriminant validity. The reliability analyses included Cronbach's α coefficient, θ coefficient, Ω coefficient, split-half reliability and test-retest reliability. This study distributed a total of 460 questionnaires, reclaimed 442, qualified 432. The score of the scale was 254.59 ± 28.90, the scores of the knowledge, attitude, behavior sub-scales were 82.44 ± 11.24, 63.53 ± 5.77 and 108.61 ± 17.55, respectively. It had excellent face validity and content validity. The correlation coefficient was from 0.71 to 0.91 among three sub-scales and the scale, P<0.001. The common factor cumulative variance contribution rate of the scale and three sub-scales was from 57.28% to 67.19%, which achieved more than 50% of the approved standard, there was 25 common factors, 91 items of the total 98 items held factor loading ≥0.40 in its relevant common factor, it had good construct validity. The scores of high group and low group in three sub-scales were: knowledge (91.12 ± 3.62) and (69.96 ± 11.20), attitude (68.75 ± 4.51) and (58.79 ± 4.87), behavior (129.38 ± 8.53) and (89.65 ± 11.34),mean scores of three sub-scales were apparently different, which compared between high score group and low score group, the t value were - 19.45, -16.24 and -30.29, respectively, P<0.001, and it had good discriminant validity. The Cronbach's α coefficient of the scale and three sub-scales was from 0.79 to 0.93, the θ coefficient was from 0.86 to 0.95, the Ω coefficient was from 0.90 to 0.98, split-half reliability was from 0.89 to 0.95.Test-retest reliability of the scale was 0.51;the three sub-scales was from 0.46 to 0.52, P<0.05. The validity and reliability of the Diabetes Self-management Knowledge, Attitude, and Behavior Assessment Scale are excellent, which is a suitable instrument to evaluate the self-management for patients with diabetes.
Laser cutting plastic materials
NASA Astrophysics Data System (ADS)
Vancleave, R. A.
1980-08-01
A 1000 watt CO2 laser was demonstrated as a reliable production machine tool for cutting of plastics, high strength reinforced composites, and other nonmetals. More than 40 different plastics were laser cut, and the results are tabulated. Applications for laser cutting described include fiberglass reinforced laminates, Kevlar/epoxy composites, fiberglass reinforced phenolics, nylon/epoxy laminates, ceramics, and disposal tooling made from acrylic.
ERIC Educational Resources Information Center
van Hover, Stephanie; Hicks, David; Cotton, Stephen
2012-01-01
While the field of history education elucidates a clear and ambitious vision of high-quality history instruction, a current challenge for history educators (including teacher educators, curriculum specialists, and school-based history and social science supervisors) becomes how to illuminate and capture this when observing classrooms to research…
Helicopter cabin noise: Methods of source and path identification and characterization
NASA Technical Reports Server (NTRS)
Murray, B. S.; Wilby, J. F.
1978-01-01
Internal noise sources in a helicopter are considered. These include propulsion machinery, comprising engine and transmission, and turbulent boundary layer effects. It is shown that by using relatively simple concepts together with careful experimental work it is possible to generate reliable data on which to base the design of high performance noise control treatments.
The Psychosocial Inventory of Ego Strengths: Examination of Theory and Psychometric Properties
ERIC Educational Resources Information Center
Markstrom, Carol A.; Marshall, Sheila K.
2007-01-01
The psychosocial inventory of ego strengths (PIES) was devised as a measure of Erikson's eight ego strengths. The present investigation extended previous research through examination of the validity and reliability of the PIES among 502 high school students. The study also included an appraisal of Erikson's ego strengths as indices of psychosocial…
Development of a Scale to Measure Educators' Practice in Teaching Self-Determination
ERIC Educational Resources Information Center
Chao, Pen-Chiang
2017-01-01
The purpose of this study was to develop a scale for assessing teachers' self-determination instruction and to test the validity and reliability of this tool. The subjects included 315 teachers recruited from elementary and junior high schools nationwide in Taiwan. The Teaching Self-Determination Scale (TSDS) developed in this study aimed at…
Refining the Assessment of Hopelessness: An Improved Way to Look to the Future
ERIC Educational Resources Information Center
Fisher, Lauren B.; Overholser, James C.
2013-01-01
Despite its high sensitivity, the Beck Hopelessness Scale (BHS) has demonstrated low specificity, has an ambiguous factor structure, and includes inadequate items. The current study examined the psychometric properties of a modified BHS (mBHS) using a Likert scale format that would allow for improved reliability, validity, and clinical utility.…
ERIC Educational Resources Information Center
Hardy, Precious; Aruguete, Mara
2014-01-01
Retention is a major problem in most colleges and universities. High dropout rates, especially in the STEM disciplines (science, technology, engineering and mathematics), have proved intractable despite the offering of supplemental instruction. A broad model of support systems that includes psychological factors is needed to address retention in…
NASA Technical Reports Server (NTRS)
Castell, Karen; Day, John H. (Technical Monitor)
2001-01-01
ST5 mission requirements include validation of Lithium-ion battery in orbit. Accommodation in the power system for Li-ion battery can be reduced with smaller amp-hour size, highly matched cells when compared to the larger amp-hour size approach. Result can be lower system mass and increased reliability.
Photovoltaic Performance and Reliability Workshop summary
NASA Astrophysics Data System (ADS)
Kroposki, Benjamin
1997-02-01
The objective of the Photovoltaic Performance and Reliability Workshop was to provide a forum where the entire photovoltaic (PV) community (manufacturers, researchers, system designers, and customers) could get together and discuss technical issues relating to PV. The workshop included presentations from twenty-five speakers and had more than one hundred attendees. This workshop also included several open sessions in which the audience and speakers could discuss technical subjects in depth. Several major topics were discussed including: PV characterization and measurements, service lifetimes for PV devices, degradation and failure mechanisms for PV devices, standardization of testing procedures, AC module performance and reliability testing, inverter performance and reliability testing, standardization of utility interconnect requirements, experience from field deployed systems, and system certification.
PV Reliability Development Lessons from JPL's Flat Plate Solar Array Project
NASA Technical Reports Server (NTRS)
Ross, Ronald G., Jr.
2013-01-01
Key reliability and engineering lessons learned from the 20-year history of the Jet Propulsion Laboratory's Flat-Plate Solar Array Project and thin film module reliability research activities are presented and analyzed. Particular emphasis is placed on lessons applicable to evolving new module technologies and the organizations involved with these technologies. The user-specific demand for reliability is a strong function of the application, its location, and its expected duration. Lessons relative to effective means of specifying reliability are described, and commonly used test requirements are assessed from the standpoint of which are the most troublesome to pass, and which correlate best with field experience. Module design lessons are also summarized, including the significance of the most frequently encountered failure mechanisms and the role of encapsulate and cell reliability in determining module reliability. Lessons pertaining to research, design, and test approaches include the historical role and usefulness of qualification tests and field tests.
Definition phase study of the grand tour missions
NASA Technical Reports Server (NTRS)
Simpson, J. A.; Meyer, P.
1972-01-01
The research to define an energetic particle experiment for the OPTGT-MJS missions is reported. The studies reported include: (1) the use of silicon dectectors for low energy, low flux level measurements in the presence of RTG radiation and trapped electrons, (2) high energy proton damage of lithium-drifted and surface barrier silicon detectors, (3) the gas Cerenkov counter, (4) systems for detection of trapped high-energy protons in the presence of trapped electrons, and (5) reliability and redundancy.
NASA Astrophysics Data System (ADS)
Kwon, Jang Yeon; Kyeong Jeong, Jae
2015-02-01
This review gives an overview of the recent progress in vacuum-based n-type transition metal oxide (TMO) thin film transistors (TFTs). Several excellent review papers regarding metal oxide TFTs in terms of fundamental electron structure, device process and reliability have been published. In particular, the required field-effect mobility of TMO TFTs has been increasing rapidly to meet the demands of the ultra-high-resolution, large panel size and three dimensional visual effects as a megatrend of flat panel displays, such as liquid crystal displays, organic light emitting diodes and flexible displays. In this regard, the effects of the TMO composition on the performance of the resulting oxide TFTs has been reviewed, and classified into binary, ternary and quaternary composition systems. In addition, the new strategic approaches including zinc oxynitride materials, double channel structures, and composite structures have been proposed recently, and were not covered in detail in previous review papers. Special attention is given to the advanced device architecture of TMO TFTs, such as back-channel-etch and self-aligned coplanar structure, which is a key technology because of their advantages including low cost fabrication, high driving speed and unwanted visual artifact-free high quality imaging. The integration process and related issues, such as etching, post treatment, low ohmic contact and Cu interconnection, required for realizing these advanced architectures are also discussed.
Teamwork as an Essential Component of High-Reliability Organizations
Baker, David P; Day, Rachel; Salas, Eduardo
2006-01-01
Organizations are increasingly becoming dynamic and unstable. This evolution has given rise to greater reliance on teams and increased complexity in terms of team composition, skills required, and degree of risk involved. High-reliability organizations (HROs) are those that exist in such hazardous environments where the consequences of errors are high, but the occurrence of error is extremely low. In this article, we argue that teamwork is an essential component of achieving high reliability particularly in health care organizations. We describe the fundamental characteristics of teams, review strategies in team training, demonstrate the criticality of teamwork in HROs and finally, identify specific challenges the health care community must address to improve teamwork and enhance reliability. PMID:16898980
76 FR 65504 - Proposed Agency Information Collection
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-21
..., including the validity of the methodology and assumptions used; (c) ways to enhance the quality, utility... Reliability Standard, FAC- 008-3--Facility Ratings, developed by the North American Electric Reliability... Reliability Standard FAC- 008-3 is pending before the Commission. The proposed Reliability Standard modifies...
Calculating system reliability with SRFYDO
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morzinski, Jerome; Anderson - Cook, Christine M; Klamann, Richard M
2010-01-01
SRFYDO is a process for estimating reliability of complex systems. Using information from all applicable sources, including full-system (flight) data, component test data, and expert (engineering) judgment, SRFYDO produces reliability estimates and predictions. It is appropriate for series systems with possibly several versions of the system which share some common components. It models reliability as a function of age and up to 2 other lifecycle (usage) covariates. Initial output from its Exploratory Data Analysis mode consists of plots and numerical summaries so that the user can check data entry and model assumptions, and help determine a final form for themore » system model. The System Reliability mode runs a complete reliability calculation using Bayesian methodology. This mode produces results that estimate reliability at the component, sub-system, and system level. The results include estimates of uncertainty, and can predict reliability at some not-too-distant time in the future. This paper presents an overview of the underlying statistical model for the analysis, discusses model assumptions, and demonstrates usage of SRFYDO.« less
Multiprocessor switch with selective pairing
Gara, Alan; Gschwind, Michael K; Salapura, Valentina
2014-03-11
System, method and computer program product for a multiprocessing system to offer selective pairing of processor cores for increased processing reliability. A selective pairing facility is provided that selectively connects, i.e., pairs, multiple microprocessor or processor cores to provide one highly reliable thread (or thread group). Each paired microprocessor or processor cores that provide one highly reliable thread for high-reliability connect with a system components such as a memory "nest" (or memory hierarchy), an optional system controller, and optional interrupt controller, optional I/O or peripheral devices, etc. The memory nest is attached to a selective pairing facility via a switch or a bus
Scheduler for multiprocessor system switch with selective pairing
Gara, Alan; Gschwind, Michael Karl; Salapura, Valentina
2015-01-06
System, method and computer program product for scheduling threads in a multiprocessing system with selective pairing of processor cores for increased processing reliability. A selective pairing facility is provided that selectively connects, i.e., pairs, multiple microprocessor or processor cores to provide one highly reliable thread (or thread group). The method configures the selective pairing facility to use checking provide one highly reliable thread for high-reliability and allocate threads to corresponding processor cores indicating need for hardware checking. The method configures the selective pairing facility to provide multiple independent cores and allocate threads to corresponding processor cores indicating inherent resilience.
Strategies for Increasing the Market Share of Recycled Products—A Games Theory Approach
NASA Astrophysics Data System (ADS)
Batzias, Dimitris F.; Pollalis, Yannis A.
2009-08-01
A methodological framework (including 28 activity stages and 10 decision nodes) has been designed under the form of an algorithmic procedure for the development of strategies for increasing the market share of recycled products within a games theory context. A case example is presented referring to a paper market, where a recycling company (RC) is in competition with a virgin-raw-material-using company (VC). The strategies of the VC, for increasing its market share, are the strengthening of (and advertisement based on) the high quality (VC1), the high reliability (VC2), the combination quality and reliability, putting emphasis on the first component (VC3), the combination quality and reliability, putting emphasis on the second component (VC4). The strategies of the RC, for increasing its market share, are proper advertisement based on the low price of produced recycled paper satisfying minimum quality requirements (RC1), the combination of low price with sensitization of the public as regards environmental and materials-saving issues, putting emphasis on the first component (RC2), the same combination, putting emphasis on the second component (RC3). Analysis of all possible situations for the case example under examination is also presented.
Reproducibility of Automated Voice Range Profiles, a Systematic Literature Review.
Printz, Trine; Rosenberg, Tine; Godballe, Christian; Dyrvig, Anne-Kirstine; Grøntved, Ågot Møller
2018-05-01
Reliable voice range profiles are of great importance when measuring effects and side effects from surgery affecting voice capacity. Automated recording systems are increasingly used, but the reproducibility of results is uncertain. Our objective was to identify and review the existing literature on test-retest accuracy of the automated voice range profile assessment. Systematic review. PubMed, Scopus, Cochrane Library, ComDisDome, Embase, and CINAHL (EBSCO). We conducted a systematic literature search of six databases from 1983 to 2016. The following keywords were used: phonetogram, voice range profile, and acoustic voice analysis. Inclusion criteria were automated recording procedure, healthy voices, and no intervention between test and retest. Test-retest values concerning fundamental frequency and voice intensity were reviewed. Of 483 abstracts, 231 full-text articles were read, resulting in six articles included in the final results. The studies found high reliability, but data are few and heterogeneous. The reviewed articles generally reported high reliability of the voice range profile, and thus clinical usefulness, but uncertainty remains because of low sample sizes and different procedures for selecting, collecting, and analyzing data. More data are needed, and clinical conclusions must be drawn with caution. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
Integrated Human-in-the-Loop Ground Testing - Value, History, and the Future
NASA Technical Reports Server (NTRS)
Henninger, Donald L.
2016-01-01
Systems for very long-duration human missions to Mars will be designed to operate reliably for many years and many of these systems will never be returned to Earth. The need for high reliability is driven by the requirement for safe functioning of remote, long-duration crewed systems and also by unsympathetic abort scenarios. Abort from a Mars mission could be as long as 450 days to return to Earth. The key to developing a human-in-the-loop architecture is a development process that allows for a logical sequence of validating successful development in a stepwise manner, with assessment of key performance parameters (KPPs) at each step; especially important are KPPs for technologies evaluated in a full systems context with human crews on Earth and on space platforms such as the ISS. This presentation will explore the implications of such an approach to technology development and validation including the roles of ground and space-based testing necessary to develop a highly reliable system for long duration human exploration missions. Historical development and systems testing from Mercury to the International Space Station (ISS) to ground testing will be reviewed. Current work as well as recommendations for future work will be described.
Rapid Modeling and Analysis Tools: Evolution, Status, Needs and Directions
NASA Technical Reports Server (NTRS)
Knight, Norman F., Jr.; Stone, Thomas J.; Ransom, Jonathan B. (Technical Monitor)
2002-01-01
Advanced aerospace systems are becoming increasingly more complex, and customers are demanding lower cost, higher performance, and high reliability. Increased demands are placed on the design engineers to collaborate and integrate design needs and objectives early in the design process to minimize risks that may occur later in the design development stage. High performance systems require better understanding of system sensitivities much earlier in the design process to meet these goals. The knowledge, skills, intuition, and experience of an individual design engineer will need to be extended significantly for the next generation of aerospace system designs. Then a collaborative effort involving the designer, rapid and reliable analysis tools and virtual experts will result in advanced aerospace systems that are safe, reliable, and efficient. This paper discusses the evolution, status, needs and directions for rapid modeling and analysis tools for structural analysis. First, the evolution of computerized design and analysis tools is briefly described. Next, the status of representative design and analysis tools is described along with a brief statement on their functionality. Then technology advancements to achieve rapid modeling and analysis are identified. Finally, potential future directions including possible prototype configurations are proposed.
Development of Equivalent Material Properties of Microbump for Simulating Chip Stacking Packaging
Lee, Chang-Chun; Tzeng, Tzai-Liang; Huang, Pei-Chen
2015-01-01
A three-dimensional integrated circuit (3D-IC) structure with a significant scale mismatch causes difficulty in analytic model construction. This paper proposes a simulation technique to introduce an equivalent material composed of microbumps and their surrounding wafer level underfill (WLUF). The mechanical properties of this equivalent material, including Young’s modulus (E), Poisson’s ratio, shear modulus, and coefficient of thermal expansion (CTE), are directly obtained by applying either a tensile load or a constant displacement, and by increasing the temperature during simulations, respectively. Analytic results indicate that at least eight microbumps at the outermost region of the chip stacking structure need to be considered as an accurate stress/strain contour in the concerned region. In addition, a factorial experimental design with analysis of variance is proposed to optimize chip stacking structure reliability with four factors: chip thickness, substrate thickness, CTE, and E-value. Analytic results show that the most significant factor is CTE of WLUF. This factor affects microbump reliability and structural warpage under a temperature cycling load and high-temperature bonding process. WLUF with low CTE and high E-value are recommended to enhance the assembly reliability of the 3D-IC architecture. PMID:28793495
Failure Mode and Effects Analysis: views of hospital staff in the UK.
Shebl, Nada; Franklin, Bryony; Barber, Nick; Burnett, Susan; Parand, Anam
2012-01-01
To explore health care professionals' experiences and perceptions of Failure Mode and Effects Analysis (FMEA), a team-based, prospective risk analysis technique. Semi-structured interviews were conducted with 21 operational leads (20 pharmacists, one nurse) in medicines management teams of hospitals participating in a national quality improvement programme. Interviews were transcribed, coded and emergent themes identified using framework analysis. Themes identified included perceptions and experiences of participants with FMEA, validity and reliability issues, and FMEA's use in practice. FMEA was considered to be a structured but subjective process that helps health care professionals get together to identify high risk areas of care. Both positive and negative opinions were expressed, with the majority of interviewees expressing positive views towards FMEA in relation to its structured nature and the use of a multidisciplinary team. Other participants criticised FMEA for being subjective and lacking validity. Most likely to restrict its widespread use were its time consuming nature and its perceived lack of validity and reliability. FMEA is a subjective but systematic tool that helps identify high risk areas, but its time consuming nature, difficulty with the scores and perceived lack of validity and reliability may limit its widespread use.
Delivery of high intensity beams with large clad step-index fibers for engine ignition
NASA Astrophysics Data System (ADS)
Joshi, Sachin; Wilvert, Nick; Yalin, Azer P.
2012-09-01
We show, for the first time, that step-index silica fibers with a large clad (400 μm core and 720 μm clad) can be used to transmit nanosecond duration pulses in a way that allows reliable (consistent) spark formation in atmospheric pressure air by the focused output light from the fiber. The high intensity (>100 GW/cm2) of the focused output light is due to the combination of high output power (typical of fibers of this core size) with high output beam quality (better than that typical of fibers of this core size). The high output beam quality, which enables tight focusing, is due to the large clad which suppresses microbending-induced diffusion of modal power to higher order modes owing to the increased rigidity of the core-clad interface. We also show that extending the pulse duration provides a means to increase the delivered pulse energy (>20 mJ delivered for 50 ns pulses) without causing fiber damage. Based on this ability to deliver high energy sparks, we report the first reliable laser ignition of a natural gas engine including startup under typical procedures using silica fiber optics for pulse delivery.
Hypsarrhythmia assessment exhibits poor interrater reliability: a threat to clinical trial validity.
Hussain, Shaun A; Kwong, Grace; Millichap, John J; Mytinger, John R; Ryan, Nicole; Matsumoto, Joyce H; Wu, Joyce Y; Lerner, Jason T; Sankar, Raman
2015-01-01
Hypsarrhythmia is the classic interictal electroencephalographic pattern associated with infantile spasms, and characterized by high voltage, disorganization, and multifocal independent epileptiform discharges. Given this seemingly simple definition, one might expect excellent interrater reliability (IRR) in the identification of this pattern. Alternatively, it may be argued that assessments of voltage and disorganization are fairly subjective, and thus quite challenging in borderline cases. We sought to test the IRR of hypsarrhythmia assessment in a systematic fashion. Six blinded pediatric electroencephalographers from four centers reviewed 22 electroencephalography (EEG) samples from patients with infantile spasms. Each sample was 5 min in duration and included only wakefulness. Raters determined if each EEG was abnormal and if hypsarrhythmia was present/absent, and characterized relevant features: voltage, organization, epileptiform discharges, slowing, interictal attenuations, symmetry, and synchrony. In addition, raters indicated their level of confidence for each assessment. Multirater kappa statistics (κ) were calculated for the assessment of hypsarrhythmia and each feature. Although IRR was favorable in determining whether a study was normal or abnormal (κ=0.89), reliability was unfavorable for assessment of hypsarrhythmia (κ=0.40), modified hypsarrhythmia (κ=0.47), high voltage (κ=0.37), disorganization (κ=0.22), multifocal epileptiform discharges (κ=0.68), interictal voltage attenuations (κ=0.21), slowing (κ=0.20), asymmetry (κ=0.26), and asynchrony (κ=0.08). Despite generally unsatisfactory interrater agreement, raters consistently reported high confidence in assessments. This study contradicts the view that hypsarrhythmia assessment is straightforward. Even small variability in the identification of hypsarrhythmia has potentially deleterious consequences for clinical care, as its presence or absence impacts decisions to pursue high-risk and high-cost therapies. These inconsistencies may similarly confound studies in which abolition of hypsarrhythmia is an outcome measure. There is a great need for practical, reliable, and unbiased measures of hypsarrhythmia. Wiley Periodicals, Inc. © 2014 International League Against Epilepsy.
An Overview of Long Duration Sodium Heat Pipe Tests
NASA Astrophysics Data System (ADS)
Rosenfeld, John H.; Ernst, Donald M.; Lindemuth, James E.; Sanzi, James L.; Geng, Steven M.; Zuo, Jon
2004-02-01
High temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, and Stirling cycle heat sources; with the resurgence of space nuclear power, additional applications include reactor heat removal elements and radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly long-term materials compatibility is being evaluated through the use of high temperature life test heat pipes. Thermacore, Inc. has carried out several sodium heat pipe life tests to establish long term operating reliability. Four sodium heat pipes have recently demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A 316L stainless steel heat pipe with a sintered porous nickel wick structure and an integral brazed cartridge heater has successfully operated at 650C to 700C for over 115,000 hours without signs of failure. A second 316L stainless steel heat pipe with a specially-designed Inconel 601 rupture disk and a sintered nickel powder wick has demonstrated over 83,000 hours at 600C to 650C with similar success. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 41,000 hours at nearly 700C. A hybrid (i.e. gas-fired and solar) heat pipe with a Haynes 230 envelope and a sintered porous nickel wick structure was operated for about 20,000 hours at nearly 700C without signs of degradation. These life test results collectively have demonstrated the potential for high temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability. Detailed design specifications, operating history, and test results are described for each of these sodium heat pipes. Lessons learned and future life test plans are also discussed.
An Overview of Long Duration Sodium Heat Pipe Tests
NASA Technical Reports Server (NTRS)
Rosenfeld, John H.; Ernst, Donald M.; Lindemuth, James E.; Sanzi, James L.; Geng, Steven M.; Zuo, Jon
2004-01-01
High temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, and Stirling cycle heat sources; with the resurgence of space nuclear power, additional applications include reactor heat removal elements and radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly long-term materials compatibility is being evaluated through the use of high temperature life test heat pipes. Thermacore International, Inc., has carried out several sodium heat pipe life tests to establish long term operating reliability. Four sodium heat pipes have recently demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A 3l6L stainless steel heat pipe with a sintered porous nickel wick structure and an integral brazed cartridge heater has successfully operated at 650 to 700 C for over 115,000 hours without signs of failure. A second 3l6L stainless steel heat pipe with a specially-designed Inconel 60 I rupture disk and a sintered nickel powder wick has demonstrated over 83,000 hours at 600 to 650 C with similar success. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 41 ,000 hours at nearly 700 0c. A hybrid (i.e. gas-fired and solar) heat pipe with a Haynes 230 envelope and a sintered porous nickel wick structure was operated for about 20,000 hours at nearly 700 C without signs of degradation. These life test results collectively have demonstrated the potential for high temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability, Detailed design specifications, operating hi story, and test results are described for each of these sodium heat pipes. Lessons learned and future life test plans are also discussed.
Spaan, Suzanne; Pronk, Anjoeka; Koch, Holger M; Jusko, Todd A; Jaddoe, Vincent W V; Shaw, Pamela A; Tiemeier, Henning M; Hofman, Albert; Pierik, Frank H; Longnecker, Matthew P
2015-05-01
The widespread use of organophosphate (OP) pesticides has resulted in ubiquitous exposure in humans, primarily through their diet. Exposure to OP pesticides may have adverse health effects, including neurobehavioral deficits in children. The optimal design of new studies requires data on the reliability of urinary measures of exposure. In the present study, urinary concentrations of six dialkyl phosphate (DAP) metabolites, the main urinary metabolites of OP pesticides, were determined in 120 pregnant women participating in the Generation R Study in Rotterdam. Intra-class correlation coefficients (ICCs) across serial urine specimens taken at <18, 18-25, and >25 weeks of pregnancy were determined to assess reliability. Geometric mean total DAP metabolite concentrations were 229 (GSD 2.2), 240 (GSD 2.1), and 224 (GSD 2.2) nmol/g creatinine across the three periods of gestation. Metabolite concentrations from the serial urine specimens in general correlated moderately. The ICCs for the six DAP metabolites ranged from 0.14 to 0.38 (0.30 for total DAPs), indicating weak to moderate reliability. Although the DAP metabolite levels observed in this study are slightly higher and slightly more correlated than in previous studies, the low to moderate reliability indicates a high degree of within-person variability, which presents challenges for designing well-powered epidemiological studies.
Oh, Deborah M; Kim, Joshua M; Garcia, Raymond E; Krilowicz, Beverly L
2005-06-01
There is increasing pressure, both from institutions central to the national scientific mission and from regional and national accrediting agencies, on natural sciences faculty to move beyond course examinations as measures of student performance and to instead develop and use reliable and valid authentic assessment measures for both individual courses and for degree-granting programs. We report here on a capstone course developed by two natural sciences departments, Biological Sciences and Chemistry/Biochemistry, which engages students in an important culminating experience, requiring synthesis of skills and knowledge developed throughout the program while providing the departments with important assessment information for use in program improvement. The student work products produced in the course, a written grant proposal, and an oral summary of the proposal, provide a rich source of data regarding student performance on an authentic assessment task. The validity and reliability of the instruments and the resulting student performance data were demonstrated by collaborative review by content experts and a variety of statistical measures of interrater reliability, including percentage agreement, intraclass correlations, and generalizability coefficients. The high interrater reliability reported when the assessment instruments were used for the first time by a group of external evaluators suggests that the assessment process and instruments reported here will be easily adopted by other natural science faculty.
Kurland, Jacquie; Naeser, Margaret A.; Baker, Errol H.; Doron, Karl; Martin, Paula I.; Seekins, Heidi E.; Bogdan, Andrew; Renshaw, Perry; Yurgelun-Todd, Deborah
2005-01-01
Cortical reorganization in poststroke aphasia is not well understood. Few studies have investigated neural mechanisms underlying language recovery in severe aphasia patients, who are typically viewed as having a poor prognosis for language recovery. Although test-retest reliability is routinely demonstrated during collection of language data in single-subject aphasia research, this is rarely examined in fMRI studies investigating the underlying neural mechanisms in aphasia recovery. The purpose of this study was to acquire fMRI test-retest data examining semantic decisions both within and between two aphasia patients. Functional MRI was utilized to image individuals with chronic, moderate-severe nonfluent aphasia during nonverbal, yes/no button-box semantic judgments of iconic sentences presented in the Computer-assisted Visual Communication (C-ViC) program. We investigated the critical issue of intra-subject reliability by exploring similarities and differences in regions of activation during participants’ performance of identical tasks twice on the same day. Each participant demonstrated high intra-subject reliability, with response decrements typical of task familiarity. Differences between participants included greater left hemisphere perilesional activation in the individual with better response to C-ViC training. This study provides fMRI reliability in chronic nonfluent aphasia, and adds to evidence supporting differences in individual cortical reorganization in aphasia recovery. PMID:15706052
Brackley, Victoria; Ball, Kevin; Tor, Elaine
2018-05-12
The effectiveness of the swimming turn is highly influential to overall performance in competitive swimming. The push-off or wall contact, within the turn phase, is directly involved in determining the speed the swimmer leaves the wall. Therefore, it is paramount to develop reliable methods to measure the wall-contact-time during the turn phase for training and research purposes. The aim of this study was to determine the concurrent validity and reliability of the Pool Pad App to measure wall-contact-time during the freestyle and backstroke tumble turn. The wall-contact-times of nine elite and sub-elite participants were recorded during their regular training sessions. Concurrent validity statistics included the standardised typical error estimate, linear analysis and effect sizes while the intraclass correlating coefficient (ICC) was used for the reliability statistics. The standardised typical error estimate resulted in a moderate Cohen's d effect size with an R 2 value of 0.80 and the ICC between the Pool Pad and 2D video footage was 0.89. Despite these measurement differences, the results from this concurrent validity and reliability analyses demonstrated that the Pool Pad is suitable for measuring wall-contact-time during the freestyle and backstroke tumble turn within a training environment.
NASA Astrophysics Data System (ADS)
Ren, Xusheng; Qian, Longsheng; Zhang, Guiyan
2005-12-01
According to Generic Reliability Assurance Requirements for Passive Optical Components GR-1221-CORE (Issue 2, January 1999), reliability determination test of different kinds of passive optical components which using in uncontrolled environments is taken. The test condition of High Temperature Storage Test (Dry Test) and Damp Test is in below sheet. Except for humidity condition, all is same. In order to save test time and cost, after a sires of contrast tests, the replacement of Dry Heat is discussed. Controlling the Failure mechanism of dry heat and damp heat of passive optical components, the contrast test of dry heat and damp heat for passive optical components (include DWDM, CWDM, Coupler, Isolator, mini Isolator) is taken. The test result of isolator is listed. Telcordia test not only test the reliability of the passive optical components, but also test the patience of the experimenter. The cost of Telcordia test in money, manpower and material resources, especially in time is heavy burden for the company. After a series of tests, we can find that Damp heat could factually test the reliability of passive optical components, and equipment manufacturer in accord with component manufacture could omit the dry heat test if damp heat test is taken first and passed.
Modeling and experimental characterization of electromigration in interconnect trees
NASA Astrophysics Data System (ADS)
Thompson, C. V.; Hau-Riege, S. P.; Andleigh, V. K.
1999-11-01
Most modeling and experimental characterization of interconnect reliability is focussed on simple straight lines terminating at pads or vias. However, laid-out integrated circuits often have interconnects with junctions and wide-to-narrow transitions. In carrying out circuit-level reliability assessments it is important to be able to assess the reliability of these more complex shapes, generally referred to as `trees.' An interconnect tree consists of continuously connected high-conductivity metal within one layer of metallization. Trees terminate at diffusion barriers at vias and contacts, and, in the general case, can have more than one terminating branch when they include junctions. We have extended the understanding of `immortality' demonstrated and analyzed for straight stud-to-stud lines, to trees of arbitrary complexity. This leads to a hierarchical approach for identifying immortal trees for specific circuit layouts and models for operation. To complete a circuit-level-reliability analysis, it is also necessary to estimate the lifetimes of the mortal trees. We have developed simulation tools that allow modeling of stress evolution and failure in arbitrarily complex trees. We are testing our models and simulations through comparisons with experiments on simple trees, such as lines broken into two segments with different currents in each segment. Models, simulations and early experimental results on the reliability of interconnect trees are shown to be consistent.
A 1 GeV CW FFAG High Intensity Proton Driver
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnstone, C.; Sheehy, S. L.
2012-05-01
The drive for high beam power, high duty cycle, and reliable beams at reasonable cost has focused world attention on fixed-field accelerators, notably Fixed-Field Alternating Gradient accelerators (FFAGs). High-intensity GeV proton drivers are of particular interest, as these encounter duty cycle and space-charge limits in the synchrotron and machine size concerns in the weaker-focusing cyclotron. Recently, the concept of isochronous orbits has been explored and developed for non-scaling FFAGs using powerful new methodologies in FFAG accelerator design. These new breeds of FFAGs have been identified by international collaborations for serious study thanks to their potential applications including Accelerator Driven Subcriticalmore » Reactors (ADS) a nd Accelerator Transmutation of Waste. The extreme reliability requirements for ADS mandate CW operation capability and the FFAG s strong focusing, particularly in the vertical, will serve to mitigate the effect of space charge (as compared with the weak- focusing cyclotron). This paper reports on these new advances in FFAG accelerator technology and presents a stable, 0.25-1GeV isochronous FFAG for an accelerator driven subcritical reactor.« less
BSA-coated nanoparticles for improved SERS-based intracellular pH sensing.
Zheng, Xiao-Shan; Hu, Pei; Cui, Yan; Zong, Cheng; Feng, Jia-Min; Wang, Xin; Ren, Bin
2014-12-16
Local microenvironment pH sensing is one of the key parameters for the understanding of many biological processes. As a noninvasive and high sensitive technique, surface-enhanced Raman spectroscopy (SERS) has attracted considerable interest in the detection of the local pH of live cells. We herein develop a facile way to prepare Au-(4-MPy)-BSA (AMB) pH nanosensor. The 4-MPy (4-mercaptopyridine) was used as the pH sensing molecule. The modification of the nanoparticles with BSA not only provides a high sensitive response to pH changes ranging from pH 4.0 to 9.0 but also exhibits a high sensitivity and good biocompatibility, stability, and reliability in various solutions (including the solutions of high ionic strength or with complex composition such as the cell culture medium), both in the aggregation state or after long-term storage. The AMB pH nanosensor shows great advantages for reliable intracellular pH analysis and has been successfully used to monitor the pH distribution of live cells and can address the grand challenges in SERS-based pH sensing for practical biological applications.
Achieving High Reliability with People, Processes, and Technology.
Saunders, Candice L; Brennan, John A
2017-01-01
High reliability as a corporate value in healthcare can be achieved by meeting the "Quadruple Aim" of improving population health, reducing per capita costs, enhancing the patient experience, and improving provider wellness. This drive starts with the board of trustees, CEO, and other senior leaders who ingrain high reliability throughout the organization. At WellStar Health System, the board developed an ambitious goal to become a top-decile health system in safety and quality metrics. To achieve this goal, WellStar has embarked on a journey toward high reliability and has committed to Lean management practices consistent with the Institute for Healthcare Improvement's definition of a high-reliability organization (HRO): one that is committed to the prevention of failure, early identification and mitigation of failure, and redesign of processes based on identifiable failures. In the end, a successful HRO can provide safe, effective, patient- and family-centered, timely, efficient, and equitable care through a convergence of people, processes, and technology.
The psychosocial inventory of ego strengths: examination of theory and psychometric properties.
Markstrom, Carol A; Marshall, Sheila K
2007-02-01
The psychosocial inventory of ego strengths (PIES) was devised as a measure of Erikson's eight ego strengths. The present investigation extended previous research through examination of the validity and reliability of the PIES among 502 high school students. The study also included an appraisal of Erikson's ego strengths as indices of psychosocial well-being. Reliability of the subscales of the PIES was shown through acceptable Cronbach's alphas. As expected, higher scores on ego strengths were positively correlated with psychosocial indictors of identity achievement, self-esteem, locus of control, empathic concern, perspective-taking, and positive forms of coping. Lower scores on ego strengths were related to less desirable psychosocial constructs. Biological sex and age differences also are reported. Based on the findings, the study offers validation of psychosocial theory. As well, the PIES is recommended for use among high school students.
A paired comparison analysis of third-party rater thyroidectomy scar preference.
Rajakumar, C; Doyle, P C; Brandt, M G; Moore, C C; Nichols, A; Franklin, J H; Yoo, J; Fung, K
2017-01-01
To determine the length and position of a thyroidectomy scar that is cosmetically most appealing to naïve raters. Images of thyroidectomy scars were reproduced on male and female necks using digital imaging software. Surgical variables studied were scar position and length. Fifteen raters were presented with 56 scar pairings and asked to identify which was preferred cosmetically. Twenty duplicate pairings were included to assess rater reliability. Analysis of variance was used to determine preference. Raters preferred low, short scars, followed by high, short scars, with long scars in either position being less desirable (p < 0.05). Twelve of 15 raters had acceptable intra-rater and inter-rater reliability. Naïve raters preferred low, short scars over the alternatives. High, short scars were the next most favourably rated. If other factors influencing incision choice are considered equal, surgeons should consider these preferences in scar position and length when planning their thyroidectomy approach.
NASA Astrophysics Data System (ADS)
Nemeth, Noel N.; Jadaan, Osama M.; Palfi, Tamas; Baker, Eric H.
Brittle materials today are being used, or considered, for a wide variety of high tech applications that operate in harsh environments, including static and rotating turbine parts, thermal protection systems, dental prosthetics, fuel cells, oxygen transport membranes, radomes, and MEMS. Designing brittle material components to sustain repeated load without fracturing while using the minimum amount of material requires the use of a probabilistic design methodology. The NASA CARES/Life 1 (Ceramic Analysis and Reliability Evaluation of Structure/Life) code provides a general-purpose analysis tool that predicts the probability of failure of a ceramic component as a function of its time in service. This capability includes predicting the time-dependent failure probability of ceramic components against catastrophic rupture when subjected to transient thermomechanical loads (including cyclic loads). The developed methodology allows for changes in material response that can occur with temperature or time (i.e. changing fatigue and Weibull parameters with temperature or time). For this article an overview of the transient reliability methodology and how this methodology is extended to account for proof testing is described. The CARES/Life code has been modified to have the ability to interface with commercially available finite element analysis (FEA) codes executed for transient load histories. Examples are provided to demonstrate the features of the methodology as implemented in the CARES/Life program.
Highly excited and exotic meson spectrum from dynamical lattice QCD.
Dudek, Jozef J; Edwards, Robert G; Peardon, Michael J; Richards, David G; Thomas, Christopher E
2009-12-31
Using a new quark-field construction algorithm and a large variational basis of operators, we extract a highly excited isovector meson spectrum on dynamical anisotropic lattices. We show how carefully constructed operators can be used to reliably identify the continuum spin of extracted states, overcoming the reduced cubic symmetry of the lattice. Using this method we extract, with confidence, excited states, states with exotic quantum numbers (0+-, 1-+, and 2+-), and states of high spin, including, for the first time in lattice QCD, spin-four states.
Automated Absorber Attachment for X-ray Microcalorimeter Arrays
NASA Technical Reports Server (NTRS)
Moseley, S.; Allen, Christine; Kilbourne, Caroline; Miller, Timothy M.; Costen, Nick; Schulte, Eric; Moseley, Samuel J.
2007-01-01
Our goal is to develop a method for the automated attachment of large numbers of absorber tiles to large format detector arrays. This development includes the fabrication of high quality, closely spaced HgTe absorber tiles that are properly positioned for pick-and-place by our FC150 flip chip bonder. The FC150 also transfers the appropriate minute amount of epoxy to the detectors for permanent attachment of the absorbers. The success of this development will replace an arduous, risky and highly manual task with a reliable, high-precision automated process.
Methods and Costs to Achieve Ultra Reliable Life Support
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2012-01-01
A published Mars mission is used to explore the methods and costs to achieve ultra reliable life support. The Mars mission and its recycling life support design are described. The life support systems were made triply redundant, implying that each individual system will have fairly good reliability. Ultra reliable life support is needed for Mars and other long, distant missions. Current systems apparently have insufficient reliability. The life cycle cost of the Mars life support system is estimated. Reliability can be increased by improving the intrinsic system reliability, adding spare parts, or by providing technically diverse redundant systems. The costs of these approaches are estimated. Adding spares is least costly but may be defeated by common cause failures. Using two technically diverse systems is effective but doubles the life cycle cost. Achieving ultra reliability is worth its high cost because the penalty for failure is very high.
2014-01-01
Background Foot disease complications, such as foot ulcers and infection, contribute to considerable morbidity and mortality. These complications are typically precipitated by “high-risk factors”, such as peripheral neuropathy and peripheral arterial disease. High-risk factors are more prevalent in specific “at risk” populations such as diabetes, kidney disease and cardiovascular disease. To the best of the authors’ knowledge a tool capturing multiple high-risk factors and foot disease complications in multiple at risk populations has yet to be tested. This study aimed to develop and test the validity and reliability of a Queensland High Risk Foot Form (QHRFF) tool. Methods The study was conducted in two phases. Phase one developed a QHRFF using an existing diabetes foot disease tool, literature searches, stakeholder groups and expert panel. Phase two tested the QHRFF for validity and reliability. Four clinicians, representing different levels of expertise, were recruited to test validity and reliability. Three cohorts of patients were recruited; one tested criterion measure reliability (n = 32), another tested criterion validity and inter-rater reliability (n = 43), and another tested intra-rater reliability (n = 19). Validity was determined using sensitivity, specificity and positive predictive values (PPV). Reliability was determined using Kappa, weighted Kappa and intra-class correlation (ICC) statistics. Results A QHRFF tool containing 46 items across seven domains was developed. Criterion measure reliability of at least moderate categories of agreement (Kappa > 0.4; ICC > 0.75) was seen in 91% (29 of 32) tested items. Criterion validity of at least moderate categories (PPV > 0.7) was seen in 83% (60 of 72) tested items. Inter- and intra-rater reliability of at least moderate categories (Kappa > 0.4; ICC > 0.75) was seen in 88% (84 of 96) and 87% (20 of 23) tested items respectively. Conclusions The QHRFF had acceptable validity and reliability across the majority of items; particularly items identifying relevant co-morbidities, high-risk factors and foot disease complications. Recommendations have been made to improve or remove identified weaker items for future QHRFF versions. Overall, the QHRFF possesses suitable practicality, validity and reliability to assess and capture relevant foot disease items across multiple at risk populations. PMID:24468080
Noble, Stephanie; Spann, Marisa N; Tokoglu, Fuyuze; Shen, Xilin; Constable, R Todd; Scheinost, Dustin
2017-11-01
Best practices are currently being developed for the acquisition and processing of resting-state magnetic resonance imaging data used to estimate brain functional organization-or "functional connectivity." Standards have been proposed based on test-retest reliability, but open questions remain. These include how amount of data per subject influences whole-brain reliability, the influence of increasing runs versus sessions, the spatial distribution of reliability, the reliability of multivariate methods, and, crucially, how reliability maps onto prediction of behavior. We collected a dataset of 12 extensively sampled individuals (144 min data each across 2 identically configured scanners) to assess test-retest reliability of whole-brain connectivity within the generalizability theory framework. We used Human Connectome Project data to replicate these analyses and relate reliability to behavioral prediction. Overall, the historical 5-min scan produced poor reliability averaged across connections. Increasing the number of sessions was more beneficial than increasing runs. Reliability was lowest for subcortical connections and highest for within-network cortical connections. Multivariate reliability was greater than univariate. Finally, reliability could not be used to improve prediction; these findings are among the first to underscore this distinction for functional connectivity. A comprehensive understanding of test-retest reliability, including its limitations, supports the development of best practices in the field. © The Author 2017. Published by Oxford University Press.
Robust object tracking techniques for vision-based 3D motion analysis applications
NASA Astrophysics Data System (ADS)
Knyaz, Vladimir A.; Zheltov, Sergey Y.; Vishnyakov, Boris V.
2016-04-01
Automated and accurate spatial motion capturing of an object is necessary for a wide variety of applications including industry and science, virtual reality and movie, medicine and sports. For the most part of applications a reliability and an accuracy of the data obtained as well as convenience for a user are the main characteristics defining the quality of the motion capture system. Among the existing systems for 3D data acquisition, based on different physical principles (accelerometry, magnetometry, time-of-flight, vision-based), optical motion capture systems have a set of advantages such as high speed of acquisition, potential for high accuracy and automation based on advanced image processing algorithms. For vision-based motion capture accurate and robust object features detecting and tracking through the video sequence are the key elements along with a level of automation of capturing process. So for providing high accuracy of obtained spatial data the developed vision-based motion capture system "Mosca" is based on photogrammetric principles of 3D measurements and supports high speed image acquisition in synchronized mode. It includes from 2 to 4 technical vision cameras for capturing video sequences of object motion. The original camera calibration and external orientation procedures provide the basis for high accuracy of 3D measurements. A set of algorithms as for detecting, identifying and tracking of similar targets, so for marker-less object motion capture is developed and tested. The results of algorithms' evaluation show high robustness and high reliability for various motion analysis tasks in technical and biomechanics applications.
Experimental application of OMA solutions on the model of industrial structure
NASA Astrophysics Data System (ADS)
Mironov, A.; Mironovs, D.
2017-10-01
It is very important and sometimes even vital to maintain reliability of industrial structures. High quality control during production and structural health monitoring (SHM) in exploitation provides reliable functioning of large, massive and remote structures, like wind generators, pipelines, power line posts, etc. This paper introduces a complex of technological and methodical solutions for SHM and diagnostics of industrial structures, including those that are actuated by periodic forces. Solutions were verified on a wind generator scaled model with integrated system of piezo-film deformation sensors. Simultaneous and multi-patch Operational Modal Analysis (OMA) approaches were implemented as methodical means for structural diagnostics and monitoring. Specially designed data processing algorithms provide objective evaluation of structural state modification.
A lightweight thermal heat switch for redundant cryocooling on satellites
NASA Astrophysics Data System (ADS)
Dietrich, M.; Euler, A.; Thummes, G.
2017-04-01
A previously designed cryogenic thermal heat switch for space applications has been optimized for low mass, high structural stability, and reliability. The heat switch makes use of the large linear thermal expansion coefficient (CTE) of the thermoplastic UHMW-PE for actuation. A structure model, which includes the temperature dependent properties of the actuator, is derived to be able to predict the contact pressure between the switch parts. This pressure was used in a thermal model in order to predict the switch performance under different heat loads and operating temperatures. The two models were used to optimize the mass and stability of the switch. Its reliability was proven by cyclic actuation of the switch and by shaker tests.
Numerical simulation of the cavitation characteristics of a mixed-flow pump
NASA Astrophysics Data System (ADS)
Chen, T.; Li, S. R.; Li, W. Z.; Liu, Y. L.; Wu, D. Z.; Wang, L. Q.
2013-12-01
As a kind of general equipment for fluid transportation, pumps were widely used in industry which includes many applications of high pressure, temperature and toxic fluids transportations. Performances of pumps affect the safety and reliability of the whole special equipment system. Cavitation in pumps cause the loss of performance and erosion of the blade, which could affect the running stability and reliability of the pump system. In this paper, a kind of numerical method for cavitaion performance prediction was presented. In order to investigate the accuracy of the method, CFD flow analysis and cavitation performance predictions of a mixed-flow pump were carried out. The numerical results were compared with the test results.
Numerical aerodynamic simulation facility. Preliminary study extension
NASA Technical Reports Server (NTRS)
1978-01-01
The production of an optimized design of key elements of the candidate facility was the primary objective of this report. This was accomplished by effort in the following tasks: (1) to further develop, optimize and describe the function description of the custom hardware; (2) to delineate trade off areas between performance, reliability, availability, serviceability, and programmability; (3) to develop metrics and models for validation of the candidate systems performance; (4) to conduct a functional simulation of the system design; (5) to perform a reliability analysis of the system design; and (6) to develop the software specifications to include a user level high level programming language, a correspondence between the programming language and instruction set and outline the operation system requirements.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-07
... Builder Cabinet Group Including On-Site Leased Workers From Reserves Network, Reliable Staffing, and Third Dimension Waverly, OH; Masco Builder Cabinet Group Including On-Site Leased Workers From Reserves Network... Group including on-site leased workers from Reserves Network, Jackson, Ohio. The workers produce...
High duty cycle hard soldered kilowatt laser diode arrays
NASA Astrophysics Data System (ADS)
Klumel, Genady; Karni, Yoram; Oppenheim, Jacob; Berk, Yuri; Shamay, Moshe; Tessler, Renana; Cohen, Shalom
2010-02-01
High-brightness laser diode arrays operating at a duty cycle of 10% - 20% are in ever-increasing demand for the optical pumping of solid state lasers and directed energy applications. Under high duty-cycle operation at 10% - 20%, passive (conductive) cooling is of limited use, while micro-coolers using de-ionized cooling water can considerably degrade device reliability. When designing and developing actively-cooled collimated laser diode arrays for high duty cycle operation, three main problems should be carefully addressed: an effective local and total heat removal, a minimization of packaging-induced and operational stresses, and high-precision fast axis collimation. In this paper, we present a novel laser diode array incorporating a built-in tap water cooling system, all-hard-solder bonded assembly, facet-passivated high-power 940 nm laser bars and tight fast axis collimation. By employing an appropriate layout of water cooling channels, careful choice of packaging materials, proper design of critical parts, and active optics alignment, we have demonstrated actively-cooled collimated laser diode arrays with extended lifetime and reliability, without compromising their efficiency, optical power density, brightness or compactness. Among the key performance benchmarks achieved are: 150 W/bar optical peak power at 10% duty cycle, >50% wallplug efficiency and <1° collimated fast axis divergence. A lifetime of >0.5 Ghots with <2% degradation has been experimentally proven. The laser diode arrays have also been successfully tested under harsh environmental conditions, including thermal cycling between -20°C and 40°C and mechanical shocks at 500g acceleration. The results of both performance and reliability testing bear out the effectiveness and robustness of the manufacturing technology for high duty-cycle laser arrays.
Gagné, Myriam; Boulet, Louis-Philippe; Pérez, Norma; Moisan, Jocelyne
2018-04-30
To systematically identify the measurement properties of patient-reported outcome instruments (PROs) that evaluate adherence to inhaled maintenance medication in adults with asthma. We conducted a systematic review of six databases. Two reviewers independently included studies on the measurement properties of PROs that evaluated adherence in asthmatic participants aged ≥18 years. Based on the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN), the reviewers (1) extracted data on internal consistency, reliability, measurement error, content validity, structural validity, hypotheses testing, cross-cultural validity, criterion validity, and responsiveness; (2) assessed the methodological quality of the included studies; (3) assessed the quality of the measurement properties (positive or negative); and (4) summarised the level of evidence (limited, moderate, or strong). We screened 6,068 records and included 15 studies (14 PROs). No studies evaluated measurement error or responsiveness. Based on methodological and measurement property quality assessments, we found limited positive evidence of: (a) internal consistency of the Adherence Questionnaire, Refined Medication Adherence Reason Scale (MAR-Scale), Medication Adherence Report Scale for Asthma (MARS-A), and Test of the Adherence to Inhalers (TAI); (b) reliability of the TAI; and (c) structural validity of the Adherence Questionnaire, MAR-Scale, MARS-A, and TAI. We also found limited negative evidence of: (d) hypotheses testing of Adherence Questionnaire; (e) reliability of the MARS-A; and (f) criterion validity of the MARS-A and TAI. Our results highlighted the need to conduct further high-quality studies that will positively evaluate the reliability, validity, and responsiveness of the available PROs. This article is protected by copyright. All rights reserved.
Communicative Access Measures for Stroke: Development and Evaluation of a Quality Improvement Tool.
Kagan, Aura; Simmons-Mackie, Nina; Victor, J Charles; Chan, Melodie T
2017-11-01
To (1) develop a systems-level quality improvement tool targeting communicative access to information and decision-making for stroke patients with language disorders; and (2) evaluate the resulting tool-the Communicative Access Measures for Stroke (CAMS). Survey development and evaluation was in line with accepted guidelines and included item generation and reduction, survey formatting and composition, pretesting, pilot testing, and reliability assessment. Development and evaluation were carried out in hospital and community agency settings. The project used a convenience sample of 31 participants for the survey development, and 63 participants for the CAMS reliability study (broken down into 6 administrators/managers, 32 frontline staff, 25 participants with aphasia). Eligible participants invited to the reliability study included individuals from 45 community-based organizations in Ontario as well as 4400 individuals from communities of practice. Not applicable. Data were analyzed using kappa statistics and intraclass correlations for each item score on all surveys. A tool, the CAMS, comprising 3 surveys, was developed for health facilities from the perspectives of (1) administrators/policymakers, (2) staff/frontline health care providers, and (3) patients with aphasia (using a communicatively accessible version). Reliability for items on the CAMS-Administrator and CAMS-Staff surveys was moderate to high (kappa/intraclass correlation coefficients [ICCs], .54-1.00). As expected, reliability was lower for the CAMS-Patient survey, with most items having ICCs between 0.4 and 0.6. These findings suggest that CAMS may provide useful quality improvement information for health care facilities with an interest in improving care for patients with stroke and aphasia. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
van Dijk, Inge; Scholten Meilink Lenferink, Nick; Lucassen, Peter L B J; Mercer, Stewart W; van Weel, Chris; Olde Hartman, Tim C; Speckens, Anne E M
2017-02-01
Empathy is an essential skill in doctor-patient communication with positive effects on compliance, patient satisfaction and symptom duration. There are no validated patient-rated empathy measures available in Dutch. To investigate the validity and reliability of a Dutch version of the Consultation and Relational Empathy (CARE) Measure, a widely used 10-item patient-rated questionnaire of physician empathy. After translation and back translation, the Dutch CARE Measure was distributed among patients from 19 general practitioners in 5 primary care centers. Tests of internal reliability and validity included Cronbach's alpha, item total correlations and factor analysis. Seven items of the QUality Of care Through the patient's Eyes (QUOTE) questionnaire assessing 'affective performance' of the physician were included in factor analysis and used to investigate convergent validity. Of the 800 distributed questionnaires, 655 (82%) were returned. Acceptability and face validity were supported by a low number of 'does not apply' responses (range 0.2%-11.9%). Internal reliability was high (Cronbach's alpha 0.974). Corrected item total correlations were at a minimum of 0.837. Factor analysis on the 10 items of the CARE Measure and 7 QUOTE items resulted in two factors (Eigenvalue > 1), the first containing the CARE Measure items and the second containing the QUOTE items. Convergent construct validity between the CARE Measure and QUOTE was confirmed with a modest positive correlation (r = 0.34, n = 654, P < 0.001). The findings support the preliminary validity and reliability of the Dutch CARE Measure. Future research is required to investigate divergent validity and discriminant ability between doctors. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Andersen, Kenneth Geving; Kehlet, Henrik; Aasvang, Eske Kvanner
2015-05-01
Quantitative sensory testing (QST) is used to assess sensory dysfunction and nerve damage by examining psychophysical responses to controlled, graded stimuli such as mechanical and thermal detection and pain thresholds. In the breast cancer population, 4 studies have used QST to examine persistent pain after breast cancer treatment, suggesting neuropathic pain being a prominent pain mechanism. However, the agreement and reliability of QST has not been described in the postsurgical breast cancer population, hindering exact interpretation of QST studies in this population. The aim of the present study was to assess test-retest properties of QST after breast cancer surgery. A total of 32 patients recruited from a larger ongoing prospective trial were examined with QST 12 months after breast cancer surgery and reexamined a week later. A standardized QST protocol was used, including sensory mapping for mechanical, warmth and cold areas of sensory dysfunction, mechanical thresholds using monofilaments and pin-prick, thermal thresholds including warmth and cold detection thresholds and heat pain threshold, with bilateral examination. Agreement and reliability were assessed by Bland-Altman plots, descriptive statistics, coefficients of variance, and intraclass correlation. Bland-Altman plots showed high variation on the surgical side. Intraclass coefficients ranged from 0.356 to 0.847 (moderate to substantial reliability). Between-patient variation was generally higher (0.9 to 14.5 SD) than within-patient variation (0.23 to 3.55 SD). There were no significant differences between pain and pain-free patients. The individual test-retest variability was higher on the operated side compared with the nonoperated side. The QST protocol reliability allows for group-to-group comparison of sensory function, but less so for individual follow-up after breast cancer surgery.
Pocket Handbook on Reliability
1975-09-01
exponencial distributions Weibull distribution, -xtimating reliability, confidence intervals, relia- bility growth, 0. P- curves, Bayesian analysis. 20 A S...introduction for those not familiar with reliability and a good refresher for those who are currently working in the area. LEWIS NERI, CHIEF...includes one or both of the following objectives: a) prediction of the current system reliability, b) projection on the system reliability for someI future
Developing Reliable Life Support for Mars
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2017-01-01
A human mission to Mars will require highly reliable life support systems. Mars life support systems may recycle water and oxygen using systems similar to those on the International Space Station (ISS). However, achieving sufficient reliability is less difficult for ISS than it will be for Mars. If an ISS system has a serious failure, it is possible to provide spare parts, or directly supply water or oxygen, or if necessary bring the crew back to Earth. Life support for Mars must be designed, tested, and improved as needed to achieve high demonstrated reliability. A quantitative reliability goal should be established and used to guide development t. The designers should select reliable components and minimize interface and integration problems. In theory a system can achieve the component-limited reliability, but testing often reveal unexpected failures due to design mistakes or flawed components. Testing should extend long enough to detect any unexpected failure modes and to verify the expected reliability. Iterated redesign and retest may be required to achieve the reliability goal. If the reliability is less than required, it may be improved by providing spare components or redundant systems. The number of spares required to achieve a given reliability goal depends on the component failure rate. If the failure rate is under estimated, the number of spares will be insufficient and the system may fail. If the design is likely to have undiscovered design or component problems, it is advisable to use dissimilar redundancy, even though this multiplies the design and development cost. In the ideal case, a human tended closed system operational test should be conducted to gain confidence in operations, maintenance, and repair. The difficulty in achieving high reliability in unproven complex systems may require the use of simpler, more mature, intrinsically higher reliability systems. The limitations of budget, schedule, and technology may suggest accepting lower and less certain expected reliability. A plan to develop reliable life support is needed to achieve the best possible reliability.
Space Radiation Effects and Reliability Consideration for the Proposed Jupiter Europa Orbiter
NASA Technical Reports Server (NTRS)
Johnston, Allan
2011-01-01
The proposed Jupiter Europa Orbiter (JEO) mission to explore the Jovian moon Europa poses a number of challenges. The spacecraft must operate for about seven years during the transit time to the vicinity of Jupiter, and then endure unusually high radiation levels during exploration and orbiting phases. The ability to withstand usually high total dose levels is critical for the mission, along with meeting the high reliability standards for flagship NASA missions. Reliability of new microelectronic components must be sufficiently understood to meet overall mission requirements.The proposed Jupiter Europa Orbiter (JEO) mission to explore the Jovian moon Europa poses a number of challenges. The spacecraft must operate for about seven years during the transit time to the vicinity of Jupiter, and then endure unusually high radiation levels during exploration and orbiting phases. The ability to withstand usually high total dose levels is critical for the mission, along with meeting the high reliability standards for flagship NASA missions. Reliability of new microelectronic components must be sufficiently understood to meet overall mission requirements.
Smith, Erin; Walsh, Lorcan; Doyle, Julie; Greene, Barry; Blake, Catherine
2016-01-01
The timed up and go (TUG) test is a commonly used assessment in older people with variations including the addition of a motor or cognitive dual-task, however in high functioning older adults it is more difficult to assess change. The quantified TUG (QTUG) uses inertial sensors to detect test and gait parameters during the test. If it is to be used in the longitudinal assessment of older adults, it is important that we know which parameters are reliable and under which conditions. This study aims to examine the relative reliability of the QTUG over five consecutive days under single, motor and cognitive dual-task conditions. Twelve community dwelling older adults (10 females, mean age 74.17 (3.88)) performed the QTUG under three conditions for five consecutive days. The relative reliability of each of the gait parameters was assessed using intra-class correlation coefficient (ICC 3,1) and standard error of measurement (SEM). Five of the measures demonstrated excellent reliability (ICC>0.70) under all three conditions (time to complete test, walk time, number of gait cycles, number of steps and return from turn time). Measures of variability and turn derived parameters demonstrated weak reliability under all three conditions (ICC=0.05-0.49). For the most reliable parameters under single-task conditions, the addition of a cognitive task resulted in a reduction in reliability suggesting caution when interpreting results under these conditions. Certain sensor derived parameters during the QTUG test may provide an additional resource in the longitudinal assessment of older people and earlier identification of falls risk. Copyright © 2015 Elsevier B.V. All rights reserved.
Strayhorn, J; McDermott, J F; Tanguay, P
1993-06-01
The effects of methods used to improve the interrater reliability of reviewers' ratings of manuscripts submitted to the Journal of the American Academy of Child and Adolescent Psychiatry were studied. Reviewers' ratings of consecutive manuscripts submitted over approximately 1 year were first analyzed; 296 pairs of ratings were studied. Intraclass correlations and confidence intervals for the correlations were computed for the two main ratings by which reviewers quantified the quality of the article: a 1-10 overall quality rating and a recommendation for acceptance or rejection with four possibilities along that continuum. Modifications were then introduced, including a multi-item rating scale and two training manuals to accompany it. Over the next year, 272 more articles were rated, and reliabilities were computed for the new scale and for the scales previously used. The intraclass correlation of the most reliable rating before the intervention was 0.27; the reliability of the new rating procedure was 0.43. The difference between these two was significant. The reliability for the new rating scale was in the fair to good range, and it became even better when the ratings of the two reviewers were averaged and the reliability stepped up by the Spearman-Brown formula. The new rating scale had excellent internal consistency and correlated highly with other quality ratings. The data confirm that the reliability of ratings of scientific articles may be improved by increasing the number of rating scale points, eliciting ratings of separate, concrete items rather than a global judgment, using training manuals, and averaging the scores of multiple reviewers.
Soleimani, Farin; Azari, Nadia; Vameghi, Roshanak; Sajedi, Firoozeh; Shahshahani, Soheila; Karimi, Hossein; Kraskian, Adis; Shahrokhi, Amin; Teymouri, Robab; Gharib, Masoud
2016-10-01
Advances in perinatal and neonatal care have substantially improved the survival of at-risk infants over the past two decades. The purpose of this study was to assess the reliability and validity of the Bayley Scales of infant and toddler developmental Screening test in Persian-speaking children. This was a cross-sectional prospective study of 403 children aged 1 - 42-months. The Bayley scales screening instrument, which consists of five domains (cognitive, receptive, and expressive communication and fine and gross motor items), was used to measure infants' and toddlers' development. The psychometric properties examined included the face and content validity of the scale, in addition to cultural and linguistic modifications to the scale and its test-retest and inter-rater reliability. An expert team changed some of the test items relating to cultural and linguistic issues. In almost all the age groups, cultural or linguistic changes were made to items in the communication domains. According to Cronbach's alpha for internal consistency, the reliability of the cognitive scale was r = 0.79, and the reliability of the receptive scale was r = 0.76. The reliability for expressive communication, fine motor, and gross motor scales was r = 0.81, r = 0.80, and r = 0.81, respectively. The construct validity of the tests was confirmed using a factor analysis and comparison of the mean scores of the age groups. The intra- and inter-rater reliabilities of the Bayley Scales were good-to-excellent. The results indicated that the Bayley Scales had a high level of reliability in the present study. Thus, the scale can be used in a Persian population.
Cost-effective solutions to maintaining smart grid reliability
NASA Astrophysics Data System (ADS)
Qin, Qiu
As the aging power systems are increasingly working closer to the capacity and thermal limits, maintaining an sufficient reliability has been of great concern to the government agency, utility companies and users. This dissertation focuses on improving the reliability of transmission and distribution systems. Based on the wide area measurements, multiple model algorithms are developed to diagnose transmission line three-phase short to ground faults in the presence of protection misoperations. The multiple model algorithms utilize the electric network dynamics to provide prompt and reliable diagnosis outcomes. Computational complexity of the diagnosis algorithm is reduced by using a two-step heuristic. The multiple model algorithm is incorporated into a hybrid simulation framework, which consist of both continuous state simulation and discrete event simulation, to study the operation of transmission systems. With hybrid simulation, line switching strategy for enhancing the tolerance to protection misoperations is studied based on the concept of security index, which involves the faulted mode probability and stability coverage. Local measurements are used to track the generator state and faulty mode probabilities are calculated in the multiple model algorithms. FACTS devices are considered as controllers for the transmission system. The placement of FACTS devices into power systems is investigated with a criterion of maintaining a prescribed level of control reconfigurability. Control reconfigurability measures the small signal combined controllability and observability of a power system with an additional requirement on fault tolerance. For the distribution systems, a hierarchical framework, including a high level recloser allocation scheme and a low level recloser placement scheme, is presented. The impacts of recloser placement on the reliability indices is analyzed. Evaluation of reliability indices in the placement process is carried out via discrete event simulation. The reliability requirements are described with probabilities and evaluated from the empirical distributions of reliability indices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeVoto, Douglas
2015-06-10
This is a technical review of the DOE VTO EDT project EDT063, Performance and Reliability of Bonded Interfaces for High-Temperature Packaging. A procedure for analyzing the reliability of sintered-silver through experimental thermal cycling and crack propagation modeling has been outlined and results have been presented.
NASA Astrophysics Data System (ADS)
Wang, Lin; Wu, Wenqi; Wei, Guo; Lian, Junxiang; Yu, Ruihang
2018-05-01
The shipboard redundant rotational inertial navigation system (RINS) configuration, including a dual-axis RINS and a single-axis RINS, can satisfy the demand of marine INSs of especially high reliability as well as achieving trade-off between position accuracy and cost. Generally, the dual-axis RINS is the master INS, and the single-axis RINS is the hot backup INS for high reliability purposes. An integrity monitoring system performs a fault detection function to ensure sailing safety. However, improving the accuracy of the backup INS in case of master INS failure has not been given enough attention. Without the aid of any external information, a systematic bias collaborative measurement method based on an augmented Kalman filter is proposed for the redundant RINSs. Estimates of inertial sensor biases can be used by the built-in integrity monitoring system to monitor the RINS running condition. On the other hand, a position error prediction model is designed for the single-axis RINS to estimate the systematic error caused by its azimuth gyro bias. After position error compensation, the position information provided by the single-axis RINS still remains highly accurate, even if the integrity monitoring system detects a dual-axis RINS fault. Moreover, use of a grid frame as a navigation frame makes the proposed method applicable in any area, including the polar regions. Semi-physical simulation and experiments including sea trials verify the validity of the method.
Tabard-Fougère, Anne; Bonnefoy-Mazure, Alice; Hanquinet, Sylviane; Lascombes, Pierre; Armand, Stéphane; Dayer, Romain
2017-01-15
Test-retest study. This study aimed to evaluate the validity and reliability of rasterstereography in patients with adolescent idiopathic scoliosis (AIS) with a major curve Cobb angle (CA) between 10° and 40° for frontal, sagittal, and transverse parameters. Previous studies evaluating the validity and reliability of rasterstereography concluded that this technique had good accuracy compared with radiographs and a high intra- and interday reliability in healthy volunteers. To the best of our knowledge, the validity and reliability have not been assessed in AIS patients. Thirty-five adolescents with AIS (male = 13) aged 13.1 ± 2.0 years were included. To evaluate the validity of the scoliosis angle (SA) provided by rasterstereography, a comparison (t test, Pearson correlation) was performed with the CA obtained using 2D EOS® radiography (XR). Three rasterstereographic repeated measurements were independently performed by two operators on the same day (interrater reliability) and again by the first operator 1 week later (intrarater reliability). The variables of interest were the SA, lumbar lordosis, and thoracic kyphosis angle, trunk length, pelvic obliquity, and maximum, root mean square and amplitude of vertebral rotations. The data analyses used intraclass correlation coefficients (ICCs). The CA and SA were strongly correlated (R = 0.70) and were nonsignificantly different (P = 0.60). The intrarater reliability (same day: ICC [1, 1], n = 35; 1 week later: ICC [1, 3], n = 28) and interrater reliability (ICC [3, 3], n = 16) were globally excellent (ICC > 0.75) except for the assessment of pelvic obliquity. This study showed that the rasterstereographic system allows for the evaluation of AIS patients with a good validity compared with XR with an overall excellent intra- and interrater reliability. Based on these results, this automatic, fast, and noninvasive system can be used for monitoring the evolution of AIS in growing patients instead of repetitive radiographs, thereby reducing radiation exposure and decreasing costs. 4.
High power diode lasers emitting from 639 nm to 690 nm
NASA Astrophysics Data System (ADS)
Bao, L.; Grimshaw, M.; DeVito, M.; Kanskar, M.; Dong, W.; Guan, X.; Zhang, S.; Patterson, J.; Dickerson, P.; Kennedy, K.; Li, S.; Haden, J.; Martinsen, R.
2014-03-01
There is increasing market demand for high power reliable red lasers for display and cinema applications. Due to the fundamental material system limit at this wavelength range, red diode lasers have lower efficiency and are more temperature sensitive, compared to 790-980 nm diode lasers. In terms of reliability, red lasers are also more sensitive to catastrophic optical mirror damage (COMD) due to the higher photon energy. Thus developing higher power-reliable red lasers is very challenging. This paper will present nLIGHT's released red products from 639 nm to 690nm, with established high performance and long-term reliability. These single emitter diode lasers can work as stand-alone singleemitter units or efficiently integrate into our compact, passively-cooled Pearl™ fiber-coupled module architectures for higher output power and improved reliability. In order to further improve power and reliability, new chip optimizations have been focused on improving epitaxial design/growth, chip configuration/processing and optical facet passivation. Initial optimization has demonstrated promising results for 639 nm diode lasers to be reliably rated at 1.5 W and 690nm diode lasers to be reliably rated at 4.0 W. Accelerated life-test has started and further design optimization are underway.
The ABC’s of Suicide Risk Assessment: Applying a Tripartite Approach to Individual Evaluations
Harris, Keith M.; Syu, Jia-Jia; Lello, Owen D.; Chew, Y. L. Eileen; Willcox, Christopher H.; Ho, Roger H. M.
2015-01-01
There is considerable need for accurate suicide risk assessment for clinical, screening, and research purposes. This study applied the tripartite affect-behavior-cognition theory, the suicidal barometer model, classical test theory, and item response theory (IRT), to develop a brief self-report measure of suicide risk that is theoretically-grounded, reliable and valid. An initial survey (n = 359) employed an iterative process to an item pool, resulting in the six-item Suicidal Affect-Behavior-Cognition Scale (SABCS). Three additional studies tested the SABCS and a highly endorsed comparison measure. Studies included two online surveys (Ns = 1007, and 713), and one prospective clinical survey (n = 72; Time 2, n = 54). Factor analyses demonstrated SABCS construct validity through unidimensionality. Internal reliability was high (α = .86-.93, split-half = .90-.94)). The scale was predictive of future suicidal behaviors and suicidality (r = .68, .73, respectively), showed convergent validity, and the SABCS-4 demonstrated clinically relevant sensitivity to change. IRT analyses revealed the SABCS captured more information than the comparison measure, and better defined participants at low, moderate, and high risk. The SABCS is the first suicide risk measure to demonstrate no differential item functioning by sex, age, or ethnicity. In all comparisons, the SABCS showed incremental improvements over a highly endorsed scale through stronger predictive ability, reliability, and other properties. The SABCS is in the public domain, with this publication, and is suitable for clinical evaluations, public screening, and research. PMID:26030590
High Availability in Optical Networks
NASA Astrophysics Data System (ADS)
Grover, Wayne D.; Wosinska, Lena; Fumagalli, Andrea
2005-09-01
Call for Papers: High Availability in Optical Networks Submission Deadline: 1 January 2006 The Journal of Optical Networking (JON) is soliciting papers for a feature Issue pertaining to all aspects of reliable components and systems for optical networks and concepts, techniques, and experience leading to high availability of services provided by optical networks. Most nations now recognize that telecommunications in all its forms -- including voice, Internet, video, and so on -- are "critical infrastructure" for the society, commerce, government, and education. Yet all these services and applications are almost completely dependent on optical networks for their realization. "Always on" or apparently unbreakable communications connectivity is the expectation from most users and for some services is the actual requirement as well. Achieving the desired level of availability of services, and doing so with some elegance and efficiency, is a meritorious goal for current researchers. This requires development and use of high-reliability components and subsystems, but also concepts for active reconfiguration and capacity planning leading to high availability of service through unseen fast-acting survivability mechanisms. The feature issue is also intended to reflect some of the most important current directions and objectives in optical networking research, which include the aspects of integrated design and operation of multilevel survivability and realization of multiple Quality-of-Protection service classes. Dynamic survivable service provisioning, or batch re-provisioning is an important current theme, as well as methods that achieve high availability at far less investment in spare capacity than required by brute force service path duplication or 100% redundant rings, which is still the surprisingly prevalent practice. Papers of several types are envisioned in the feature issue, including outlook and forecasting types of treatments, optimization and analysis, new concepts for survivability, or papers on availability analysis methods or results. Customer, vendor, and researcher viewpoints and priorities will all be given consideration. Especially valuable to the community would be papers that include or provide measured data on actual reliability and availability performance of optical networking components or systems. The scope of the papers includes, but is not limited to, the following topics: Reliability and availability measurement techniques specific to optical network devices or services. Data on SRLG statistics and frequency of different actual failure causes. Real-life accounts or data on failure and repair rates or projected values for use in availability analysis. Availability analysis methods, especially for survivable networks with reconfigurable or adaptive failure-specific responses. Availability analysis and comparisons of basic schemes for survivability. Differentiated availability schemes. Design for Multiple Quality of Protection. Different schemes for on-demand survivable service provisioning. Basic comparisons or proposals of new survivability mechanisms and architectures. Concepts yielding higher than 1+1 protection switching availability at less than 100% redundancy. Survivable service provisioning in domains of optical transparency: dealing with signal impairments. To submit to this special issue, follow the normal procedure for submission to JON, indicating "Feature Issue: Optical Network Availability" in the "Comments" field of the online submission form. For all other questions relating to this feature issue, please send an e-mail to jon@osa.org, subject line "Feature Issue: Optical Network Availability." Additional information can be found on the JON website: http://www.osa-jon.org/submission/
Translated Versions of Voice Handicap Index (VHI)-30 across Languages: A Systematic Review
SEIFPANAHI, Sadegh; JALAIE, Shohreh; NIKOO, Mohammad Reza; SOBHANI-RAD, Davood
2015-01-01
Background: In this systematic review, the aim is to investigate different VHI-30 versions between languages regarding their validity, reliability and their translation process. Methods: Articles were extracted systematically from some of the prime databases including Cochrane, googlescholar, MEDLINE (via PubMed gate), Sciencedirect, Web of science, and their reference lists by Voice Handicap Index keyword with only title limitation and time of publication (from 1997 to 2014). However the other limitations (e.g. excluding non-English, other versions of VHI ones, and so on) applied manually after studying the papers. In order to appraise the methodology of the papers, three authors did it by 12-item diagnostic test checklist in “Critical Appraisal Skills Programme” or (CASP) site. After applying all of the screenings, the papers that had the study eligibility criteria such as; translation, validity, and reliability processes, included in this review. Results: The remained non-repeated articles were 12 from different languages. All of them reported validity, reliability and translation method, which presented in details in this review. Conclusion: Mainly the preferred method for translation in the gathered papers was “Brislin’s classic back-translation model (1970), although the procedure was not performed completely but it was more prominent than other translation procedures. High test-retest reliability, internal consistency and moderate construct validity between different languages in regards to all 3 VHI-30 domains confirm the applicability of translated VHI-30 version across languages. PMID:26056664
AHRQ's hospital survey on patient safety culture: psychometric analyses.
Blegen, Mary A; Gearhart, Susan; O'Brien, Roxanne; Sehgal, Niraj L; Alldredge, Brian K
2009-09-01
This project analyzed the psychometric properties of the Agency for Healthcare Research and Quality Hospital Survey on Patient Safety Culture (HSOPSC) including factor structure, interitem reliability and intraclass correlations, usefulness for assessment, predictive validity, and sensitivity. The survey was administered to 454 health care staff in 3 hospitals before and after a series of multidisciplinary interventions designed to improve safety culture. Respondents (before, 434; after, 368) included nurses, physicians, pharmacists, and other hospital staff members. Factor analysis partially confirmed the validity of the HSOPSC subscales. Interitem consistency reliability was above 0.7 for 5 subscales; the staffing subscale had the lowest reliability coefficients. The intraclass correlation coefficients, agreement among the members of each unit, were within recommended ranges. The pattern of high and low scores across the subscales of the HSOPSC in the study hospitals were similar to the sample of Pacific region hospitals reported by the Agency for Healthcare Research and Quality and corresponded to the proportion of items in each subscale that are worded negatively (reverse scored). Most of the unit and hospital dimensions were correlated with the Safety Grade outcome measure in the tool. Overall, the tool was shown to have moderate-to-strong validity and reliability, with the exception of the staffing subscale. The usefulness in assessing areas of strength and weakness for hospitals or units among the culture subscales is questionable. The culture subscales were shown to correlate with the perceived outcomes, but further study is needed to determine true predictive validity.
CCARES: A computer algorithm for the reliability analysis of laminated CMC components
NASA Technical Reports Server (NTRS)
Duffy, Stephen F.; Gyekenyesi, John P.
1993-01-01
Structural components produced from laminated CMC (ceramic matrix composite) materials are being considered for a broad range of aerospace applications that include various structural components for the national aerospace plane, the space shuttle main engine, and advanced gas turbines. Specifically, these applications include segmented engine liners, small missile engine turbine rotors, and exhaust nozzles. Use of these materials allows for improvements in fuel efficiency due to increased engine temperatures and pressures, which in turn generate more power and thrust. Furthermore, this class of materials offers significant potential for raising the thrust-to-weight ratio of gas turbine engines by tailoring directions of high specific reliability. The emerging composite systems, particularly those with silicon nitride or silicon carbide matrix, can compete with metals in many demanding applications. Laminated CMC prototypes have already demonstrated functional capabilities at temperatures approaching 1400 C, which is well beyond the operational limits of most metallic materials. Laminated CMC material systems have several mechanical characteristics which must be carefully considered in the design process. Test bed software programs are needed that incorporate stochastic design concepts that are user friendly, computationally efficient, and have flexible architectures that readily incorporate changes in design philosophy. The CCARES (Composite Ceramics Analysis and Reliability Evaluation of Structures) program is representative of an effort to fill this need. CCARES is a public domain computer algorithm, coupled to a general purpose finite element program, which predicts the fast fracture reliability of a structural component under multiaxial loading conditions.
The 1988 Goddard Space Flight Center Battery Workshop
NASA Technical Reports Server (NTRS)
Yi, Thomas Y. (Editor)
1993-01-01
This document contains the proceedings of the 21st annual Battery Workshop held at Goddard Space Flight Center, Greenbelt, Maryland on November 1-3, 1988. The Workshop attendees included manufacturers, users, and government representatives interested in the latest developments in battery technology as they relate to high reliability operations and aerospace use. The subjects covered included battery testing methodologies and criteria, life testing of nickel-cadmium cells, testing and operation of nickel-hydrogen batteries in low earth orbit, and nickel-hydrogen technology issues and concerns.
The 1987 Goddard Space Flight Center Battery Workshop
NASA Technical Reports Server (NTRS)
Morrow, George (Editor); Yi, Thomas Y. (Editor)
1993-01-01
This document contains the proceedings of the 20th annual Battery Workshop held at Goddard Space Flight Center, Greenbelt, Maryland on November 4-5, 1987. The workshop attendees included manufacturers, users, and government representatives interested in the latest developments in battery technology as they relate to high reliability operations and aerospace use. The subjects covered included lithium cell technology and safety improvements, nickel-cadmium electrode technology along with associated modifications, flight experience and life testing of nickel-cadmium cells, and nickel-hydrogen applications and technology.