Sample records for including ria loading

  1. Fuel cladding behavior under rapid loading conditions

    NASA Astrophysics Data System (ADS)

    Yueh, K.; Karlsson, J.; Stjärnsäter, J.; Schrire, D.; Ledergerber, G.; Munoz-Reja, C.; Hallstadius, L.

    2016-02-01

    A modified burst test (MBT) was used in an extensive test program to characterize fuel cladding failure behavior under rapid loading conditions. The MBT differs from a normal burst test with the use of a driver tube to simulate the expansion of a fuel pellet, thereby producing a partial strain driven deformation condition similar to that of a fuel pellet expansion in a reactivity insertion accident (RIA). A piston/cylinder assembly was used to pressurize the driver tube. By controlling the speed and distance the piston travels the loading rate and degree of sample deformation could be controlled. The use of a driver tube with a machined gauge section localizes deformation and allows for continuous monitoring of the test sample diameter change at the location of maximum hoop strain, during each test. Cladding samples from five irradiated fuel rods were tested between 296 and 553 K and loading rates from 1.5 to 3.5/s. The test rods included variations of Zircaloy-2 with different liners and ZIRLO, ranging in burn-up from 41 to 74 GWd/MTU. The test results show cladding ductility is strongly temperature and loading rate dependent. Zircaloy-2 cladding ductility degradation due to operational hydrogen pickup started to recover at approximately 358 K for test condition used in the study. This recovery temperature is strongly loading rate dependent. At 373 K, ductility recovery was small for loading rates less than 8 ms equivalent RIA pulse width, but longer than 8 ms the ductility recovery increased exponentially with increasing pulse width, consistent with literature observations of loading rate dependent brittle-to-ductile (BTD) transition temperature. The cladding ductility was also observed to be strongly loading rate/pulse width dependent for BWR cladding below the BTD temperature and Pressurized Water Reactor (PWR) cladding at both 296 and 553 K.

  2. Postabsorptive hyperglucagonemia in patients with type 2 diabetes mellitus analyzed with a novel enzyme-linked immunosorbent assay.

    PubMed

    Matsuo, Toshihiro; Miyagawa, Jun-Ichiro; Kusunoki, Yoshiki; Miuchi, Masayuki; Ikawa, Takashi; Akagami, Takafumi; Tokuda, Masaru; Katsuno, Tomoyuki; Kushida, Akira; Inagaki, Takashi; Namba, Mitsuyoshi

    2016-05-01

    The aims of the present study were to investigate the performance of a novel sandwich enzyme-linked immunosorbent assay (ELISA) for measuring glucagon (1-29) with monoclonal antibodies against both the C- and N-terminal regions of glucagon (1-29), and to analyze the differences in plasma levels and responses of glucagon (1-29) to oral glucose loading in normal glucose tolerance (NGT) subjects and patients with type 2 diabetes mellitus. The cross-reactivity against proglucagon fragments using the ELISA kit and two types of conventional radioimmunoassay (RIA) kits was evaluated. A 75-g oral glucose tolerance test was carried out with NGT subjects and patients with type 2 diabetes mellitus, and the glucagon (1-29) concentration was measured using three types of kit. The ELISA kit clearly had the lowest cross-reactivity against miniglucagon (19-29) and glicentin (1-61). The oral glucose tolerance test was carried out with 30 NGT and 17 patients with type 2 diabetes mellitus. The glucagon (1-29) levels measured by the ELISA kit after glucose loading were significantly higher at all time-points in the type 2 diabetes mellitus group than in the NGT group. However, the glucagon (1-29) levels measured by one RIA kit were significantly higher in the NGT group, and those measured with the other RIA kit were approximately the same among the groups. The novel sandwich ELISA accurately determines plasma glucagon (1-29) concentrations with much less cross-reactivity against other proglucagon fragments than conventional RIA kits.

  3. Reactivity Insertion Accident (RIA) Capability Status in the BISON Fuel Performance Code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williamson, Richard L.; Folsom, Charles Pearson; Pastore, Giovanni

    2016-05-01

    One of the Challenge Problems being considered within CASL relates to modelling and simulation of Light Water Reactor LWR) fuel under Reactivity Insertion Accident (RIA) conditions. BISON is the fuel performance code used within CASL for LWR fuel under both normal operating and accident conditions, and thus must be capable of addressing the RIA challenge problem. This report outlines required BISON capabilities for RIAs and describes the current status of the code. Information on recent accident capability enhancements, application of BISON to a RIA benchmark exercise, and plans for validation to RIA behavior are included.

  4. Abandonment of antiretroviral therapy among HIV-positive patients attended at the reference center for HIV/AIDS in Vitória, Brazil.

    PubMed

    Zago, Adriana Marchon; Morelato, Paola; Endringer, Emmanuele de Angeli; Dan, Germano de Freitas; Ribeiro, Evanira Mendes; Miranda, Angelica Espinosa

    2012-01-01

    This study evaluates the risk factors for the abandonment of antiretroviral therapy (ART) among patients receiving care in an AIDS clinic in Vitória, Brazil. We conducted a case-control study of patients with AIDS attending a reference center for sexually transmitted disease (STD)/AIDS. A total of 62 patients, who abandoned therapy in 2008, and 188 HIV-infected patients answered an interview including demographic, social, and clinical characteristics. Risk factors associated with abandon in univariate analysis were entered into logistic regression models. A total of 250 patients were included in the study. Groups were similar regarding age, gender, and monthly income. In the final multivariate model, illicit drug use (adjusted odds ratio [AOR], 2.3; 95% confidence interval [CI], 1.03-5.07), previous abandon of medication (AOR 38.6; 95% CI 10.49-142.25), last CD4 count <200 cells/mm(3) (AOR 1.5; 95% CI 1.03-2.10), and viral load higher than 1000 copies/mL (AOR 2.0 (95% CI 1.34-3.09) were independent predictors of abandonment of ART. In addition to the clinical indicators, behavioral factors remained important throughout the multivariate analysis in our study.

  5. An ATR-FTIR Study on the Effect of Molecular Structural Variations on the CO2 Absorption Characteristics of Heterocyclic Amines, Part II

    PubMed Central

    Robinson, Kelly; McCluskey, Adam; Attalla, Moetaz I

    2012-01-01

    This paper reports on an ATR-FTIR spectroscopic investigation of the CO2 absorption characteristics of a series of heterocyclic diamines: hexahydropyrimidine (HHPY), 2-methyl and 2,2-dimethylhexahydropyrimidine (MHHPY and DMHHPY), hexahydropyridazine (HHPZ), piperazine (PZ) and 2,5- and 2,6-dimethylpiperazine (2,6-DMPZ and 2,5-DMPZ). By using in situ ATR-FTIR the structure–activity relationship of the reaction between heterocyclic diamines and CO2 is probed. PZ forms a hydrolysis-resistant carbamate derivative, while HHPY forms a more labile carbamate species with increased susceptibility to hydrolysis, particularly at higher CO2 loadings (>0.5 mol CO2/mol amine). HHPY exhibits similar reactivity toward CO2 to PZ, but with improved aqueous solubility. The α-methyl-substituted MHHPY favours HCO3− formation, but MHHPY exhibits comparable CO2 absorption capacity to conventional amines MEA and DEA. MHHPY show improved reactivity compared to the conventional α-methyl- substituted primary amine 2-amino-2-methyl-1-propanol. DMHHPY is representative of blended amine systems, and its reactivity highlights the advantages of such systems. HHPZ is relatively unreactive towards CO2. The CO2 absorption capacity CA (mol CO2/mol amine) and initial rates of absorption RIA (mol CO2/mol amine min−1) for each reactive diamine are determined: PZ: CA=0.92, RIA=0.045; 2,6-DMPZ: CA=0.86, RIA=0.025; 2,5-DMPZ: CA=0.88, RIA=0.018; HHPY: CA=0.85, RIA=0.032; MHHPY: CA=0.86, RIA=0.018; DMHHPY: CA=1.1, RIA=0.032; and HHPZ: no reaction. Calculations at the B3LYP/6-31+G** and MP2/6-31+G** calculations show that the substitution patterns of the heterocyclic diamines affect carbamate stability, which influences hydrolysis rates. PMID:22517608

  6. Association of Xerostomia and Ultrasonographic Features of the Major Salivary Glands After Radioactive Iodine Ablation for Papillary Thyroid Carcinoma.

    PubMed

    Soo Roh, Sang; Wook Kim, Dong; Jin Baek, Hye

    2016-11-01

    The objective of this study is to evaluate the association between xerostomia and sonographic features of the major salivary glands after patients undergo radioactive iodine ablation (RIA) for papillary thyroid carcinoma (PTC). The study included 256 consecutive patients who underwent total thyroidectomy, RIA, and neck ultrasound examinations. Changes in the ultrasound features of the parotid and submandibular glands after RIA were evaluated retrospectively by a single radiologist, on the basis of direct comparison of sonograms obtained before and after RIA. Clinical data, including the presence of xerostomia, were investigated retrospectively by the same radiologist via a review of the electronic medical records. For 111 of the 256 patients (43.4%), ultrasound examination revealed changes in the major salivary glands after RIA. The presence of xerostomia was undetermined in 85 of the 256 patients. Among the remaining 171 patients, the frequency of xerostomia was 36.8% (63/171). When patients with xerostomia were compared with those without xerostomia, no statistically significant differences in patient sex and age, the dose of RIA received, or the number of RIA sessions were noted (p > 0.05). Considering the changes in the ultrasound features of the major salivary glands after RIA, no statistically significant association was found between xerostomia and the number of involved major salivary glands or the presence of an involved submandibular gland (p > 0.05). In this study, ultrasound was unhelpful for evaluating xerostomia after RIA in patients with PTC.

  7. Lagoon-sea exchanges, nutrient dynamics and water quality management of the Ria Formosa (Portugal)

    NASA Astrophysics Data System (ADS)

    Newton, Alice; Mudge, Stephen M.

    2005-02-01

    Historical data from the Ria Formosa lagoon are classified according to the EEA 2001 guidelines to provide a frame of reference to evaluate the effect of management during the implementation of the environmental legislative Directives. Water samples from the Ria Formosa lagoon were significantly enriched in nitrogen (NH 4+ NO 2- and NO 3-) with respect to the adjacent coastal waters indicating that inputs from sewage, agricultural runoff and benthic fluxes were not fully assimilated within the lagoon. Tidal flushing was insufficient in the inner areas of the lagoon to remove or effectively dilute these inputs. Enrichment was most severe close to the urban centres of Faro and Olhão, as well as in the Gilão Estuary and the shallow extremities. Dissolved oxygen undersaturation (mean 75% during daylight hours) was associated with the area close to the sewage outlets of Faro. In the shallow west end of the lagoon during summer, dissolved oxygen supersaturation reached 140% during the day but fell to 50% at night. Classification using the EEA (2001) guidelines suggests the system is "poor" or "bad" with respect to phosphate concentrations for the majority of the year and "poor" in nitrogen contamination during the autumn rainy period. Due to the high overall nitrogen load in the lagoon, there is a net export to the coastal waters, especially during November and December, and phosphate only becomes limiting briefly during the spring bloom (April). Therefore, substantial phytoplankton populations may be supported year-round in the lagoon. The consequences of water quality deterioration in the Ria Formosa would negatively affect the lagoon as a regional resource, important for its ecological, economic and recreational value. The industries most affected would be tourism, fisheries and aquaculture. Management options include Urban Waste Water Treatment, dredging, artificial inlets, limits on urban development and changes in agricultural practices.

  8. Regulatory Impact Analysis: Amendments to the National Emission Standards for Hazardous Air Pollutants (NESHAP) and New Source Perofrmance Standards (NSPS) for the Portland Cement Manufacturing Industry Final Report

    EPA Pesticide Factsheets

    For the regulatory process, EPA is required to develop a regulatory impact analysis (RIA). This August 2010 RIA includes an economic impact analysis (EIA) and a small entity impacts analysis and documents the RIA methods and results for the 2010 rules

  9. Laser Cutting

    DTIC Science & Technology

    1988-06-01

    gantry configuration, however, presents a cage-like barrier to the rapid loading and unloading of workpieces such as automobile bodies or body...assemblies almost as large as an automobile . System controls can follow cutting paths within a few thousandths of an inch while producing such path detail...are often called robots. Indeed, they meet the RIA* definition of an industrial robot as follows: "A reprogrammable multifunctional manipulator designed

  10. The interaction of N-glycans in Fcγ receptor I α-chain with Escherichia coli K1 outer membrane protein A for entry into macrophages: experimental and computational analysis.

    PubMed

    Krishnan, Subramanian; Liu, Fan; Abrol, Ravinder; Hodges, Jacqueline; Goddard, William A; Prasadarao, Nemani V

    2014-11-07

    Neonatal meningitis, caused by Escherichia coli K1, is a serious central nervous system disease. We have established that macrophages serve as permissive niches for E. coli K1 to multiply in the host and for attaining a threshold level of bacterial load, which is a prerequisite for the onset of the disease. Here, we demonstrate experimentally that three N-glycans in FcγRIa interact with OmpA of E. coli K1 for binding to and entering the macrophages. Adoptive transfer of FcγRIa(-/-) bone marrow-derived macrophages transfected with FcγRIa into FcγRIa(-/-) newborn mice renders them susceptible to E. coli K1-induced meningitis. In contrast, mice that received bone marrow-derived macrophages transfected with FcγRIa in which N-glycosylation sites 1, 4, and 5 are mutated to alanines exhibit resistance to E. coli K1 infection. Our molecular dynamics and simulation studies predict that N-glycan 5 exhibits strong binding at the barrel site of OmpA formed by loops 3 and 4, whereas N-glycans 1 and 4 interact with loops 1, 3, and 4 of OmpA at tip regions. Molecular modeling data also suggest no role for the IgG binding site in the invasion process. In agreement, experimental mutations in IgG binding site had no effect on the E. coli K1 entry into macrophages in vitro or on the onset of meningitis in newborn mice. Together, this integration of experimental and computational studies reveals how the N-glycans in FcγRIa interact with the OmpA of E. coli K1 for inducing the disease pathogenesis. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.

  11. Baseline Assessment of Mesophotic Reefs of the Vitória-Trindade Seamount Chain Based on Water Quality, Microbial Diversity, Benthic Cover and Fish Biomass Data.

    PubMed

    Meirelles, Pedro M; Amado-Filho, Gilberto M; Pereira-Filho, Guilherme H; Pinheiro, Hudson T; de Moura, Rodrigo L; Joyeux, Jean-Christophe; Mazzei, Eric F; Bastos, Alex C; Edwards, Robert A; Dinsdale, Elizabeth; Paranhos, Rodolfo; Santos, Eidy O; Iida, Tetsuya; Gotoh, Kazuyoshi; Nakamura, Shota; Sawabe, Tomoo; Rezende, Carlos E; Gadelha, Luiz M R; Francini-Filho, Ronaldo B; Thompson, Cristiane; Thompson, Fabiano L

    2015-01-01

    Seamounts are considered important sources of biodiversity and minerals. However, their biodiversity and health status are not well understood; therefore, potential conservation problems are unknown. The mesophotic reefs of the Vitória-Trindade Seamount Chain (VTC) were investigated via benthic community and fish surveys, metagenomic and water chemistry analyses, and water microbial abundance estimations. The VTC is a mosaic of reef systems and includes fleshy algae dominated rhodolith beds, crustose coralline algae (CCA) reefs, and turf algae dominated rocky reefs of varying health levels. Macro-carnivores and larger fish presented higher biomass at the CCA reefs (4.4 kg per frame) than in the rhodolith beds and rocky reefs (0.0 to 0.1 kg per frame). A larger number of metagenomic sequences identified as primary producers (e.g., Chlorophyta and Streptophyta) were found at the CCA reefs. However, the rocky reefs contained more diseased corals (>90%) than the CCA reefs (~40%) and rhodolith beds (~10%). Metagenomic analyses indicated a heterotrophic and fast-growing microbiome in rocky reef corals that may possibly lead to unhealthy conditions possibly enhanced by environmental features (e.g. light stress and high loads of labile dissolved organic carbon). VTC mounts represent important hotspots of biodiversity that deserve further conservation actions.

  12. Characterisation of heavy metal discharge into the Ria of Huelva.

    PubMed

    Sainz, A; Grande, J A; de la Torre, M L

    2004-06-01

    The Ria of Huelva estuary, in SW Spain, is known to be one of the most heavy metal contaminated estuaries in the world. River contribution to the estuary of dissolved Cu, Zn, Mn, Cr, Ni, Cd, and As were analysed for the period 1988-2001. The obtained mean values show that this contribution, both because of the magnitude of total metals (895.1 kg/h), composition, toxicity (8.7 kg/h of As+Cd+Pb) and persistence, is an incomparable case in heavy metal contamination of estuaries. The amount and typology of heavy metal discharge to the Ria of Huelva are related to freshwater flow (and, consequently, to rainfall); as a result, two different types of heavy metal discharge can be distinguished in the estuary: during low water (50% of the days), with only 19.3 kg/h of heavy metals, and during high water or flood (17% of the days), where daily maximum discharge of 72,475 kg of heavy metals were recorded, from which 1481 kg were of As, 470 kg of Pb, and 170 kg of Cd. In the most frequent situation (77% of the days), the Odiel River discharges from 90% to 100% of the freshwater received by the estuary. Despite this, the high concentration of heavy metals in the Tinto River water causes this river to discharge into the Ria of Huelva 12.5% of fluvial total dissolved metal load received by the estuary.

  13. [Homocysteine after a methionine load in healthy subjects with adequate B-vitamin status].

    PubMed

    López-Alarcón, Mardia; Chávez-Negrete, Adolfo; Montalvo-Velarde, Irene; Maldonado-Hernández, Jorge; Vital-Reyes, Víctor Saúl

    2011-01-01

    Plasma homocysteine (Hcy) determination at 6-8 h after an oral methionine load (OML) allows for identification of some, but not all, individuals at risk to develop cardiovascular disease. It is probable that in some cases the Hcy increases occur later, or it elevates between normal ranges but in a sustained manner. However, the entire Hcy response curve has not been described. We undertook this study to determine Hcy concentrations from baseline to 24- and 48-h after an OML in non-B-vitamin deficient adult subjects with other risk factors for high levels of Hcy such as smoking and overweight. In a cross-over, clinical design, Hcy concentrations were determined at 2-h intervals throughout 12 h and at 24 h and 48 h after an OML (0.1 g/kg). Hcy and vitamin B6 (VB6) concentrations were measured by high-performance liquid chromatography (HPLC). Folic acid (FA) and vitamin B12 (VB12) were measured by radioimmunoassay (RIA). Statistical analysis included delta values and areas under the curve. Student t-test and repeated measurement analyses were conducted to control for confounders. Twenty-nine subjects with adequate Hcy, FA, VB6 and VB12 status were included. The maximum Hcy concentration occurred 8 h after the load and returned to baseline concentrations after 24 h. All subjects presented Hcy after the load within normal ranges, but smoking and overweight synergistically influenced the response to the challenge, producing a sustained elevation after the dose. Hcy concentrations after an OML remained above baseline for at least 24 h. Smoking and overweight affected the response to the methionine challenge.

  14. Baseline Assessment of Mesophotic Reefs of the Vitória-Trindade Seamount Chain Based on Water Quality, Microbial Diversity, Benthic Cover and Fish Biomass Data

    PubMed Central

    Meirelles, Pedro M.; Amado-Filho, Gilberto M.; Pereira-Filho, Guilherme H.; Pinheiro, Hudson T.; de Moura, Rodrigo L.; Joyeux, Jean-Christophe; Mazzei, Eric F.; Bastos, Alex C.; Edwards, Robert A.; Dinsdale, Elizabeth; Paranhos, Rodolfo; Santos, Eidy O.; Iida, Tetsuya; Gotoh, Kazuyoshi; Nakamura, Shota; Sawabe, Tomoo; Rezende, Carlos E.; Gadelha, Luiz M. R.; Francini-Filho, Ronaldo B.; Thompson, Cristiane; Thompson, Fabiano L.

    2015-01-01

    Seamounts are considered important sources of biodiversity and minerals. However, their biodiversity and health status are not well understood; therefore, potential conservation problems are unknown. The mesophotic reefs of the Vitória-Trindade Seamount Chain (VTC) were investigated via benthic community and fish surveys, metagenomic and water chemistry analyses, and water microbial abundance estimations. The VTC is a mosaic of reef systems and includes fleshy algae dominated rhodolith beds, crustose coralline algae (CCA) reefs, and turf algae dominated rocky reefs of varying health levels. Macro-carnivores and larger fish presented higher biomass at the CCA reefs (4.4 kg per frame) than in the rhodolith beds and rocky reefs (0.0 to 0.1 kg per frame). A larger number of metagenomic sequences identified as primary producers (e.g., Chlorophyta and Streptophyta) were found at the CCA reefs. However, the rocky reefs contained more diseased corals (>90%) than the CCA reefs (~40%) and rhodolith beds (~10%). Metagenomic analyses indicated a heterotrophic and fast-growing microbiome in rocky reef corals that may possibly lead to unhealthy conditions possibly enhanced by environmental features (e.g. light stress and high loads of labile dissolved organic carbon). VTC mounts represent important hotspots of biodiversity that deserve further conservation actions. PMID:26090804

  15. The Interaction of N-Glycans in Fcγ Receptor I α-Chain with Escherichia coli K1 Outer Membrane Protein A for Entry into Macrophages

    PubMed Central

    Krishnan, Subramanian; Liu, Fan; Abrol, Ravinder; Hodges, Jacqueline; Goddard, William A.; Prasadarao, Nemani V.

    2014-01-01

    Neonatal meningitis, caused by Escherichia coli K1, is a serious central nervous system disease. We have established that macrophages serve as permissive niches for E. coli K1 to multiply in the host and for attaining a threshold level of bacterial load, which is a prerequisite for the onset of the disease. Here, we demonstrate experimentally that three N-glycans in FcγRIa interact with OmpA of E. coli K1 for binding to and entering the macrophages. Adoptive transfer of FcγRIa−/− bone marrow-derived macrophages transfected with FcγRIa into FcγRIa−/− newborn mice renders them susceptible to E. coli K1-induced meningitis. In contrast, mice that received bone marrow-derived macrophages transfected with FcγRIa in which N-glycosylation sites 1, 4, and 5 are mutated to alanines exhibit resistance to E. coli K1 infection. Our molecular dynamics and simulation studies predict that N-glycan 5 exhibits strong binding at the barrel site of OmpA formed by loops 3 and 4, whereas N-glycans 1 and 4 interact with loops 1, 3, and 4 of OmpA at tip regions. Molecular modeling data also suggest no role for the IgG binding site in the invasion process. In agreement, experimental mutations in IgG binding site had no effect on the E. coli K1 entry into macrophages in vitro or on the onset of meningitis in newborn mice. Together, this integration of experimental and computational studies reveals how the N-glycans in FcγRIa interact with the OmpA of E. coli K1 for inducing the disease pathogenesis. PMID:25231998

  16. High burnup fuel behavior related to fission gas effects under reactivity initiated accidents (RIA) conditions

    NASA Astrophysics Data System (ADS)

    Lemoine, F.

    1997-09-01

    Specific aspects of irradiated fuel result from the increasing retention of gaseous and volatile fission products with burnup, which, under overpower conditions, can lead to solid fuel pressurization and swelling causing severe PCMI (pellet clad mechanical interaction). In order to assess the reliability of high burnup fuel under RIAs, experimental programs have been initiated which have provided important data concerning the transient fission gas behavior and the clad loading mechanisms. The importance of the rim zone is demonstrated based on three experiments resulting in clad failure at low enthalpy, which are explained by energetic considerations. High gas release in non-failure tests with low energy deposition underlines the importance of grain boundary and porosity gas. Measured final releases are strongly correlated to the microstructure evolution, depending on energy deposition, pulse width, initial and refabricated fuel rod design. Observed helium release can also increase internal pressure and gives hints to the gas behavior understanding.

  17. Highly sensitive immuno-assays for the determination of cotinine in serum and saliva. Comparison between RIA and an avidin-biotin ELISA.

    PubMed

    Benkirane, S; Nicolas, A; Galteau, M M; Siest, G

    1991-06-01

    Two immuno-assay methods (RIA and ELISA) have been developed for the accurate and sensitive measurement of cotinine in human body fluids (serum, saliva). RIA uses [3H]cotinine as antigen and charcoal/dextran for separating cotinine-bound antibodies from the free derivative. Another technique (ELISA) was developed to avoid the use of radio-labelled compounds and to determine cotinine in large populations, including passive or non-smokers who usually present very low concentrations. The two techniques were analytically validated. The detection limit was similar (0.1 micrograms/l) and the precision was better than 10% for both techniques. Non-smoker values ranged from 0.1 to 17 micrograms/l by ELISA and 0.1 to 27.5 micrograms/l by RIA, whereas smoker values ranged from 50 to 1000 micrograms/l (ELISA) and from 70 to 800 micrograms/l (RIA). The comparative analysis of cotinine in 96 human sera revealed a good correlation between the two methods (r = 0.97) and a reliable discrimination between the populations of non-smokers and smokers. As usual, the ELISA is more rapid (4 h 30 min) than the RIA (longer than 48 h). ELISA is proposed for use in the epidemiological investigation of the human tobacco risk.

  18. Comparison of two insulin assays for first-phase insulin release in type 1 diabetes prediction and prevention studies

    PubMed Central

    Mahon, Jeffrey L.; Beam, Craig A.; Marcovina, Santica M.; Boulware, David C.; Palmer, Jerry P.; Winter, William E.; Skyler, Jay S.; Krischer, Jeffrey P.

    2018-01-01

    Background Detection of below-threshold first-phase insulin release or FPIR (1 + 3 minute insulin concentrations during an intravenous glucose tolerance test [IVGTT]) is important in type 1 diabetes prediction and prevention studies including the TrialNet Oral Insulin Prevention Trial. We assessed whether an insulin immunoenzymometric assay (IEMA) could replace the less practical but current standard of a radioimmunoassay (RIA) for FPIR. Methods One hundred thirty-three islet autoantibody positive relatives of persons with type 1 diabetes underwent 161 IVGTTs. Insulin concentrations were measured by both assays in 1056 paired samples. A rule classifying FPIR (below-threshold, above-threshold, uncertain) by the IEMA was derived and validated against FPIR by the RIA. Results The insulin IEMA-based rule accurately classified below- and above-threshold FPIRs by the RIA in 110/161 (68%) IVGTTs, but was uncertain in 51/161 (32%) tests for which FPIR by RIA is needed. An uncertain FPIR by the IEMA was more likely among below-threshold vs above-threshold FPIRs by the RIA (64% [30/47] vs. 18% [21/114], respectively; p < 0.05). Conclusions An insulin IEMA for FPIR in subjects at risk for type 1 diabetes accurately determined below- and above-threshold FPIRs in 2/3 of tests relative to the current standard of the insulin RIA, but could not reliably classify the remaining FPIRs. TrialNet is limiting the insulin RIA for FPIR to the latter given the practical advantages of the more specific IEMA. PMID:21843518

  19. The reamer-irrigator-aspirator as a device for harvesting bone graft compared with iliac crest bone graft: union rates and complications.

    PubMed

    Dawson, John; Kiner, Dirk; Gardner, Warren; Swafford, Rachel; Nowotarski, Peter J

    2014-10-01

    This study was performed to compare patient outcomes after Reamer-Irrigator-Aspirator (RIA)-harvested bone grafting with the current gold standard, either anterior or posterior iliac crest bone graft (ICBG). Prospective randomized controlled trial. Multicenter study at 3 geographically separate Level 1 trauma centers. One hundred thirty-three patients with nonunion or posttraumatic segmental bone defect requiring operative intervention. Patients were prospectively randomized to receive ICBG or RIA autograft. Supplemental internal fixation was performed per surgeon preference. Operative data included amount of graft, time of harvest, and associated surgical costs. The Short Musculoskeletal Functional Assessment and the Visual Analog Scale were used to document baseline and postoperative function and pain. Clinical and radiographic union was the defined end point; patients considered to have failed treatment if they either developed an infection requiring operative treatment or had a persistent nonunion of the grafted extremity. One hundred thirteen of the 133 enrolled patients were followed until union and included in the final analysis. Intraoperative data showed anterior ICBG to yield 20.7 ± 12.8 (5-60) cm of autograft with an average harvest time of 33.2 ± 16.2 minutes, posterior ICBG yielded 36.1 ± 21.3 (20-100) cm of autograft in 40.6 ± 11.2 minutes, and RIA yielded 37.7 ± 12.9 (5-90) cm in 29.4 ± 15.1 minutes. Anterior ICBG produced significantly less bone graft than either RIA or posterior ICBG (P < 0.001). The RIA harvest was completed in significantly less operative time compared with posterior ICBG (P = 0.005). At $738, the RIA setup was considerably more expensive than the ∼$100 cost of a bone graft tray; however, when compared with posterior ICBG, the longer operative time required for a posterior harvest came at an additional incremental cost of $990-1880, making RIA the less expensive option. Patients were followed for an average of 56.9 ± 42.1 (11-250) weeks. Forty-nine of 57 patients (86.0%) who received ICBG united in an average of 22.5 ± 13.2 weeks; 46 of 56 patients (82.1%) who received RIA healed in an average of 25.8 ± 17.0 weeks. Union rates and time to union were comparable between the 2 procedures. There was no difference in complications requiring reoperation for persistent nonunion or infection at the grafted site, nor there was any difference in donor-site complications. Postoperative follow-up showed that RIA patients had significantly lower donor-site pain scores throughout follow-up. When compared with autograft obtained from the iliac crest, autograft harvested using the RIA technique achieves similar union rates with significantly less donor-site pain. RIA also yields a greater volume of graft compared with anterior ICBG and has a shorter harvest time compared with posterior ICBG. For larger volume harvests, cost analysis favors using RIA. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  20. Comparison of two insulin assays for first-phase insulin release in type 1 diabetes prediction and prevention studies.

    PubMed

    Mahon, Jeffrey L; Beam, Craig A; Marcovina, Santica M; Boulware, David C; Palmer, Jerry P; Winter, William E; Skyler, Jay S; Krischer, Jeffrey P

    2011-11-20

    Detection of below-threshold first-phase insulin release or FPIR (1+3 minute insulin concentrations during an intravenous glucose tolerance test [IVGTT]) is important in type 1 diabetes prediction and prevention studies including the TrialNet Oral Insulin Prevention Trial. We assessed whether an insulin immunoenzymometric assay (IEMA) could replace the less practical but current standard of a radioimmunoassay (RIA) for FPIR. One hundred thirty-three islet autoantibody positive relatives of persons with type 1 diabetes underwent 161 IVGTTs. Insulin concentrations were measured by both assays in 1056 paired samples. A rule classifying FPIR (below-threshold, above-threshold, uncertain) by the IEMA was derived and validated against FPIR by the RIA. The insulin IEMA-based rule accurately classified below- and above-threshold FPIRs by the RIA in 110/161 (68%) IVGTTs, but was uncertain in 51/161 (32%) tests for which FPIR by RIA is needed. An uncertain FPIR by the IEMA was more likely among below-threshold vs above-threshold FPIRs by the RIA (64% [30/47] vs. 18% [21/114], respectively; p<0.05). An insulin IEMA for FPIR in subjects at risk for type 1 diabetes accurately determined below- and above-threshold FPIRs in 2/3 of tests relative to the current standard of the insulin RIA, but could not reliably classify the remaining FPIRs. TrialNet is limiting the insulin RIA for FPIR to the latter given the practical advantages of the more specific IEMA. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Assay of anti-HBs antibodies using a recombinant antigen and latex particle counting: comparison with five commercial tests.

    PubMed

    Galanti, L M; Cornu, C; Masson, P L; Robert, A R; Becheanu, D; Lamy, M E; Cambiaso, C L

    1991-05-01

    An assay of anti-HBs antibodies based on agglutination of latex particles coated with recombinant HBs-antigen was compared with Abbott radioimmunoassay (Abbott-RIA), which uses a human plasma-derived antigen. The population examined consisted of 76 Abbott-RIA anti-HBs-negative prevaccinated subjects and 1044 serum samples anti-HBs found positive by Abbott-RIA, including 283 samples of subjects vaccinated either with a human plasma-derived vaccine (group A; n = 180) or with a recombinant vaccine (group B; n = 103). Correlation coefficients between the two techniques were respectively r = 0.89 for the whole population (n = 1044), r = 0.98 in group A and r = 0.74 in group B. Anti-HBs titres were higher with latex than with RIA in group B as shown by the regression slopes: latex = 508 + 1.11 RIA in group A and latex = -1138 + 3.97 RIA in group B, suggesting that some vaccinated subjects from group B produced antibodies against epitopes proper to the recombinant antigen. In the prevaccinated population and in group A, the latex results were compared with those of radioimmunoassays (Abbott, Sorin) and enzyme immunoassays (Behring, Roche, Pasteur). Only the Roche-EIA detected anti-HBs in the prevaccinated subjects. The correlation between the various immunoassays was r greater than 0.96 only for values higher than 100 IU/l.

  2. Gene expression profiling reveals distinct molecular signatures associated with the rupture of intracranial aneurysm.

    PubMed

    Nakaoka, Hirofumi; Tajima, Atsushi; Yoneyama, Taku; Hosomichi, Kazuyoshi; Kasuya, Hidetoshi; Mizutani, Tohru; Inoue, Ituro

    2014-08-01

    The rupture of intracranial aneurysm (IA) causes subarachnoid hemorrhage associated with high morbidity and mortality. We compared gene expression profiles in aneurysmal domes between unruptured IAs and ruptured IAs (RIAs) to elucidate biological mechanisms predisposing to the rupture of IA. We determined gene expression levels of 8 RIAs, 5 unruptured IAs, and 10 superficial temporal arteries with the Agilent microarrays. To explore biological heterogeneity of IAs, we classified the samples into subgroups showing similar gene expression patterns, using clustering methods. The clustering analysis identified 4 groups: superficial temporal arteries and unruptured IAs were aggregated into their own clusters, whereas RIAs segregated into 2 distinct subgroups (early and late RIAs). Comparing gene expression levels between early RIAs and unruptured IAs, we identified 430 upregulated and 617 downregulated genes in early RIAs. The upregulated genes were associated with inflammatory and immune responses and phagocytosis including S100/calgranulin genes (S100A8, S100A9, and S100A12). The downregulated genes suggest mechanical weakness of aneurysm walls. The expressions of Krüppel-like family of transcription factors (KLF2, KLF12, and KLF15), which were anti-inflammatory regulators, and CDKN2A, which was located on chromosome 9p21 that was the most consistently replicated locus in genome-wide association studies of IA, were also downregulated. We demonstrate that gene expression patterns of RIAs were different according to the age of patients. The results suggest that macrophage-mediated inflammation is a key biological pathway for IA rupture. The identified genes can be good candidates for molecular markers of rupture-prone IAs and therapeutic targets. © 2014 American Heart Association, Inc.

  3. Comparison of 2 enzyme immunoassays and a radioimmunoassay for measurement of progesterone concentrations in bovine plasma, skim milk, and whole milk.

    PubMed

    Colazo, Marcos G; Ambrose, Divakar J; Kastelic, John P; Small, Julie A

    2008-01-01

    The objective of this study was to compare 2 enzyme immunoassays (EIAs) with a radioimmunoassay (RIA) as to sensitivity and accuracy in the measurement of the progesterone (P4) concentration in bovine plasma, skim milk, and whole milk. The 72 samples from 24 lactating dairy cows expected to have either a high P4 concentration (cows in diestrus or pregnant) or a low P4 concentration (cows in estrus or anestrus) were analyzed by RIA, solid-phase EIA (SPEIA), which included a solvent extraction step, or direct EIA (DEIA) without solvent extraction. The overall mean concentrations of P4 did not differ (P < 0.4) among the assays. However, for the cows that were in diestrus or pregnant, the mean P4 concentrations (and standard error) were higher (P < 0.03), regardless of sample type, with RIA than with SPEIA, at 7.3 (0.7) and 6.1 (0.6) ng/mL, respectively. When only the high-P4 samples analyzed by RIA were compared, the mean P4 concentration was higher (P < 0.001) in whole milk than in skim milk, at 9.8 (1.0) and 4.1 (0.7) ng/mL, respectively. Although the mean P4 concentrations in the low-P4 samples did not differ (P < 0.80) among assays, the proportions of cows with a P4 concentration > or = 1 ng/mL were 3%, 14%, and 44% for RIA, SPEIA, and DEIA, respectively (P < 0.01; DEIA > SPEIA > RIA).

  4. Comparison of cyclosporine determinations in whole blood by three different methods. HPLC, /sup 125/I RIA and /sup 3/H RIA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, W.Y.; Lipsey, A.I.; Cheng, M.H.

    1987-04-01

    The authors have analyzed and compared the cyclosporine concentrations in whole blood specimens from pediatric renal transplant patients using three different methods: high-performance liquid chromatography (HPLC) (5u C18 reverse-phase column), /sup 3/H radioimmunoassay (RIA), and /sup 125/I RIA (substituted /sup 3/H-tracer in Sandoz Kit with /sup 125/I tracer. Results obtained by the /sup 125/I RIA correlated well with results obtained by the /sup 3/H RIA. Both RIA methods had similar correlation with the HPLC method. The /sup 125/I RIA method showed higher sensitivity and greater precision than the /sup 3/H RIA method. The authors conclude that the /sup 125/I RIAmore » method can be used for cyclosporine determination in whole blood specimens. The use of the /sup 125/I RIA provides a simple and rapid method with higher counting efficiency and less background quenching than the /sup 3/H RIA method, which requires cumbersome liquid scintillation counting procedures.« less

  5. MR Enterography Assessment of Bowel Inflammation Severity in Crohn Disease Using the MR Index of Activity Score: Modifying Roles of DWI and Effects of Contrast Phases.

    PubMed

    Kim, Jin Sil; Jang, Hye Young; Park, Seong Ho; Kim, Kyung-Jo; Han, Kyunghwa; Yang, Suk-Kyun; Ye, Byong Duk; Park, Sang Hyoung; Lee, Jong Seok; Kim, Hyun Jin

    2017-05-01

    The purpose of this article is to appraise the use of the MR index of activity (MaRIA) score in evaluating Crohn disease (CD) on present-day MR enterography images, with an emphasis on determining the modifying roles of DWI and the effects of different contrast enhancement phases. Fifty patients prospectively underwent MR enterography, including DWI and enteric and portal phase scans, and ileocolonoscopy with segmental CD endoscopic index of severity (CDEIS) scoring within a week. Thirty-nine terminal ilea and 40 right-sided colons (mean [± SD] segmental CDEIS score, 14.3 ± 12.1) from 42 patients with CD (mean age, 27 ± 6.2 years) were finally analyzed by three independent readers. Original and modified (ulcer replaced with DWI grade) MaRIA scores were compared regarding their correlation with segmental CDEIS score, accuracy in diagnosing active (segmental CDEIS score ≥ 3) and severe (segmental CDEIS score ≥ 12) inflammation, and interobserver reproducibility. The primary analysis used portal phase data, and the agreement between portal and enteric phase scores was analyzed. MaRIA and modified MaRIA scores correlated similarly with CDEIS scores (r = 0.737 and 0.742; p = 0.387) and did not significantly differ in terms of AUC values for the diagnosis of active (0.909 and 0.903; p = 0.571) or severe (0.907 and 0.892; p = 0.443) inflammation. The intraclass correlation coefficient was significantly higher for modified MaRIA than for MaRIA (0.845 and 0.701; p < 0.001). The mean difference between portal and enteric phase scores (i.e., portal minus enteric) was 0.33-0.36 score points for individual readers, and the Bland-Altman repeatability coefficient was 0.9-1.42 score points. Interobserver reproducibility in evaluating the severity of bowel inflammation in CD using the MaRIA score can be improved by modification with DWI. MaRIA scoring provides steady results across enteric and portal phases.

  6. Neutronics Assessments for a RIA Fragmentation Line Beam Dump Concept

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boles, J L; Reyes, S; Ahle, L E

    Heavy ion and radiation transport calculations are in progress for conceptual beam dump designs for the fragmentation line of the proposed Rare Isotope Accelerator (RIA). Using the computer code PHITS, a preliminary design of a motor-driven rotating wheel beam dump and adjacent downstream multipole has been modeled. Selected results of these calculations are given, including neutron and proton flux in the wheel, absorbed dose and displacements per atom in the hub materials, and heating from prompt radiation and from decay heat in the multipole.

  7. Intimate partner violence and repeat induced abortion in Italy: A cross sectional study.

    PubMed

    Citernesi, Angela; Dubini, Valeria; Uglietti, Anna; Ricci, Elena; Cipriani, Sonia; Parazzini, Fabio

    2015-01-01

    To investigate the impact of intimate partner violence (IPV) on the risk of repeat induced abortion (RIA), we compared IPV history among women with and without previous induced abortion (IA). All consecutive women aged 18 years or more requiring IA in 12 Italian abortion clinics were eligible for inclusion in the study. They were asked to fill in an anonymous, self-developed questionnaire assessing sociodemographic data and their history of different types of violence and related risk factors. The analysis included 1030 women, 624 (60.6%) of whom reported a previous IA. Past or current IPV was reported by 19.3%: 7.0% reported sexual violence, 11.3% physical abuse and 12.1% psychological abuse. Past or current IPV was reported by 22.3% of women with RIA and 14.8% of those undergoing their first IA (adjusted odds ratio 1.57, 95% confidence interval 1.07-2.30; p = 0.02). When we considered sexual, psychological and physical abuse separately, we found that any kind of abuse was more frequent in women with RIA than in women with no previous IA. This study underlines the impact of IPV on the risk of RIA and suggests the need for screening for IPV among women requiring abortion, in order to identify women at risk of RIA and to improve their general and reproductive health.

  8. Relaxation-induced anxiety: Effects of peak and trajectories of change on treatment outcome for generalized anxiety disorder.

    PubMed

    Newman, Michelle G; Lafreniere, Lucas S; Jacobson, Nicholas C

    2018-07-01

    Evidence is mixed regarding whether relaxation-induced anxiety (RIA) impedes relaxation training (RT) efficacy. Unlike past studies that averaged RIA across sessions, we examined peak RIA, change in RIA level across sessions, and timing of peak RIA with outcome. This was a secondary analysis of Borkovec, Newman, Pincus, and Lytle [2002. A component analysis of cognitive-behavioral therapy for generalized anxiety disorder and the role of interpersonal problems. Journal of Consulting and Clinical Psychology, 70, 288-298. doi: 10.1037/0022-006X.70.2.288 ]. Forty-one GAD participants were assigned randomly to CBT (n = 22) or BT (n = 19). Both treatments contained RT and RIA ratings within 13/14 sessions. Analyses used generalized additive mixed models (GAMMs), which accounted for longitudinal nonindependence and examined nonlinear trajectories of change. All participants improved significantly regardless of RIA. "Change trajectory of RIA level did not predict outcome". Instead, lower peak RIA predicted fewer GAD symptoms at post-treatment and greater likelihood to continue to improve during follow-up. Also, timing of peak was important. Whereas lower peak early in therapy did not predict outcome, lower peak during the last third of treatment did. Peak RIA's effect was neither accounted for by baseline symptom severity, treatment condition, comorbidity, nor by preceding or concurrent anxiety symptom change. People with consistently low peak RIA and/or who fully habituate to RIA by the end of therapy respond optimally to relaxation-based treatments.

  9. Holocene facies analysis of the sedimentary record with anthropogenic impacts in the Ria de Vigo (NW Spain)

    NASA Astrophysics Data System (ADS)

    Rubio, B.; Garcia-Gil, S.; Vilas, F.; Garcia, A.

    2004-05-01

    The Ria de Vigo constitutes the southernmost ria of the Rias Bajas. The reconnaisance studies of this ria indicate a heterogeneous distribution of both terrigenous and carbonate sediments with a major axial deposit of cohesive sediments. These fine sediments are relatively rich in organic matter, particularly in the inner part of the ria. This is the result of a progressive change in hydrodynamic conditions along the ria. The outer parts are affected by severe storms in winter and by upwelling processes in summer, whilst the inner parts have an estuarine character throughout the year. The upwelling produces a marked increase in the biological productivity in the Ria and, consequently, these sediments have typically very high contents of organic matter. In recent years, increasing interest has been shown in the levels of heavy metals in sediments of the Galician Rias. Particularly, some of these studies showed a higher concentration of heavy metals in the muddiest surficial sediments in the Ria de Vigo. However, and despite of the important human and industrial settlement in the Galician rias, knowledge about the evolution of historical contamination along the Holocene sedimentary record is scarce. In order to ascertain this evolution have been selected 8 gravity corer located along the axial part of the ria. This evaluation was focused on the muddy sediments of the axial part of the ria due to the dependence of metal levels on grain size, resulting from the association of metals with the finer particles, as it has been demonstrated by previous studies in the ria. On these sediments, the combination of geochemical, mineralogical and sedimentological data, facies interpretations (obtained from x-ray radiography), and their integration with high resolution seismic data (Uniboom and 3.5 Khz subbottom profiler) have allowed to establish the evolution of certain heavy metals (Zn, Cu and Pb) along the Holocene recent sedimentary record in the Ria de Vigo. Sediments in the outer ria are comprised by muddy sands showing a very slight enrichment in certain heavy metals in the upper sediments. Contrary to facies in the outer ria sediments, facies in the inner ria comprises finer organic-rich sediments. These are related to the presence of biodeposits produced by mussel rafts and to a higher anthropogenic influence due to industrial activity. Both influences are notably reflected in the Cu, Zn and Pb vertical profiles, increasing markedly the levels of these metals in the uppermost 0.15 m of sediments. Diagenetic recycling may contribute to the enhancement of trace metal concentrations in the upper sediments of inner cores and also this is related to a higher content of organic carbon in these sediments. Results obtained in this ria constitutes a good reference to study other rias and coastal areas of the Iberian Atlantic margin. This work was funded by projects REN2003-02822 MAR, REN2003-03233 MAR, VEM2003-20093-C03-03 of the Spanish MCYT and PGDIT03RMA30101PR of the Galician Government (XUGA). Contribution No 302 XM2 group.

  10. Twentieth century overview of heavy metals in the Galician Rias (NW Iberian Peninsula).

    PubMed

    Prego, R; Cobelo-García, A

    2003-01-01

    The 18 Galician Rias, comprising 25% of the Iberian Peninsula coastline, form a unique system within the European continental Atlantic coast and provide a useful reference area for studies of metals. These rias are sensitive to anthropogenic influence due to the socioeconomic importance generated in these areas by industry, aquaculture, port activities, fishing, tourism and, accordingly, several islands lying within close proximity to the rias have recently been declared natural parks. Aquaculture in the Galician Rias is a growth industry and in 2000 the rias supported 3386 mussel rafts producing 2.5 x 10(8) kg year(-1), i.e. 40% of European Union total seafood production. The Galician Rias are partially stratified estuaries with positive residual circulation with fresh (runoff lower than 100 m3 s(-1) and salt water mixing inside the basins. This behaviour has direct consequences on metal fluxes whereby the rias behave as a barrier and accumulate metals in the sediments. Metals tend to deposit close to point sources and remobilization occurs inside the ria, leading to a seaward decrease in metal concentration. With the exception of the Ulla (Arosa Ria) and Eume (Ares-Betanzos Ria) head rivers and the Lagares river (Vigo Ria) the available data suggest that riverine freshwater inputs are not the main source of contamination. Metal studies reported in the literature mainly relate to Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb and Zn, and to a lesser extent Hg and Sn. Studies of other harmful metals such as Ag, Se and As are notably lacking. In addition, the studies have been localized and mainly restricted to the surface sediment. Data of heavy metals in the dissolved phase, suspended particulate matter and biota is scarce in the mainstream literature and should be considered in the future research. From the entire Galician coast, data from seven rias of socio-economic importance form the bulk of the published work. There is an urgent need to standardize procedures, employ 'clean' procedures to avoid contamination of samples and regular assessment of analytical accuracy with CRMs in order that results can be compared among the scientific community and produce reliable results. The continuation of coastal environmental studies requires an enlargement of the sampling locations as well as systematic and periodic analysis of known pollution sources in order to decide whether coastal regeneration action is needed. Studies dedicated to metals in the water column are lacking and need more attention in future research. The majority of the available data correspond to the fluvial front (30%) at ria head and, to a lesser extent, to the oceanic front (3%), under summer upwelling events. Current awareness of the rias suggests that they are not contaminated although there is some evidence of important localized anthropogenically induced enrichments at the outflow of the Lagares River (Pb, Zn), the San Simón inlet (Pb) and near to the harbor (Pb, Zn, Cu) in the Vigo Ria, the inner part (Cu, Zn, Hg, Pb) of the Pontevedra Ria, the Ulla River estuary (Cu, Cr, Mn, Ni; Zn) in the Arosa Ria, the inner zone (Cu, Pb, Zn) of the Coruña Ria, the Ferrol Ria (Zn) and the Eume Estuary (Zn, Mn, Ni, Co) in the Ares-Betanzos Ria. In addition, TBT enrichment has been found along the Galician coast, being highest in the industrial bays (Vigo, Coruña and Ferrol). Nevertheless, it is important to point out the lack of information concerning the relationship between metal concentrations in different fractions of sediments and/or water and their bioavailability and toxicity on biota in order to confirm metal contamination dangers. The present paper reviews all the information published on metals in the rias up to the year 2000 and takes a biogeochemical standpoint, i.e. metal presence in the ria reservoirs: water column, suspended particulate matter, sediments and biota, as well as the fluvial and oceanic frontiers.

  11. Analysis of relevant proteins from bone graft harvested using the reamer irrigator and aspirator system (RIA) versus iliac crest (IC) bone graft and RIA waste water.

    PubMed

    Crist, Brett D; Stoker, Aaron M; Stannard, James P; Cook, James L

    2016-08-01

    Femoral reaming using a Reamer Irrigator Aspirator (RIA) can produce greater than three liters of waste water per procedure, which contains cells and proteins that could promote bone healing. This purpose of this study was to determine the protein profile of RIA waste water and compare protein synthesis by cells harvested via RIA versus iliac crest (IC) bone graft. Bone graft was collected from 30 patients-15 using RIA from the femur and 15 harvested from the iliac crest. Waste water collected during the RIA procedure was analyzed in 12 patients. Cells from each graft were cultured in monolayer using growth media for 14days and inductive media for the next 14days. Media samples were collected on days 14, 21, and 28. Proteins for analysis were chosen based on their potential in bone healing, pro-inflammatory, and anti-inflammatory processes. Proteins present in RIA waste water indicate the potential for clinical use of this filtrate as an adjunct for enhancing bone production, healing, and remodeling. Similarly, cells cultured from RIA bone graft harvests compared favorably to those from iliac crest bone grafts with respect to their potential to aid in bone healing. RIA waste water has potential to serve as an autogenic and allogenic enhancer for bone healing. Continued development of processing protocols for viable commercial use of the waste water and pre-clinical studies designed to evaluate RIA waste water products for bone healing are ongoing. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Cell-Based Screen Identifies Human Interferon-Stimulated Regulators of Listeria monocytogenes Infection

    PubMed Central

    Eitson, Jennifer L.; Chen, Didi; Jimenez, Alyssa; Mettlen, Marcel; Schoggins, John W.; Alto, Neal M.

    2016-01-01

    The type I interferon (IFN) activated transcriptional response is a critical antiviral defense mechanism, yet its role in bacterial pathogenesis remains less well characterized. Using an intracellular pathogen Listeria monocytogenes (Lm) as a model bacterial pathogen, we sought to identify the roles of individual interferon-stimulated genes (ISGs) in context of bacterial infection. Previously, IFN has been implicated in both restricting and promoting Lm growth and immune stimulatory functions in vivo. Here we adapted a gain-of-function flow cytometry based approach to screen a library of more than 350 human ISGs for inhibitors and enhancers of Lm infection. We identify 6 genes, including UNC93B1, MYD88, AQP9, and TRIM14 that potently inhibit Lm infection. These inhibitors act through both transcription-mediated (MYD88) and non-transcriptional mechanisms (TRIM14). Further, we identify and characterize the human high affinity immunoglobulin receptor FcγRIa as an enhancer of Lm internalization. Our results reveal that FcγRIa promotes Lm uptake in the absence of known host Lm internalization receptors (E-cadherin and c-Met) as well as bacterial surface internalins (InlA and InlB). Additionally, FcγRIa-mediated uptake occurs independently of Lm opsonization or canonical FcγRIa signaling. Finally, we established the contribution of FcγRIa to Lm infection in phagocytic cells, thus potentially linking the IFN response to a novel bacterial uptake pathway. Together, these studies provide an experimental and conceptual basis for deciphering the role of IFN in bacterial defense and virulence at single-gene resolution. PMID:28002492

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeffries, H P

    As a test of the hypothesis that fatty acid patterns of entire planktonic communities should be less variable and more predictable in offshore waters than estuarine habitats, monthly samples have been taken in Block Island Sound, Narragansett Bay, and Green Hill Pond (a brackish lagoon), R.I. Observations include physical environmental properties, standing crop estimates, and fatty acid distribution in two size fractions - phytoplankton-microzooplankton and zooplankton. A second hypothesis states that the annual sample trajectory of a zooplankton community displayed in biochemical(fatty acid) phase space is related to production, but only under certain circumstances. Samples were also taken along themore » major axes of Ria de Arosa and Ria de Muros y Noya, two deep embayments on the Atlantic coast of northern Spain. Results on the first hypothesis show that each system in the gradient of environmental severity behaves individually during the autumnal cooling period, when plankton production declines to annual minima. Spatial distribution of zooplankton in the two adjacent Spanish rias differ completely, both qualitatively and quantitatively. A comparison between the Spanish rias and the three US estuaries should reveal the basic nature of chemically defined stable domain in community structure. From these relations, the fate of communities subjected to either natural stressors or anthrogenic perturbation may be predicted with economy, speed, and objectivity.« less

  14. Coastal Human Actions on Natural Morph-dynamics around RIA of FOZ (NW Spain). Risk Analysis.

    NASA Astrophysics Data System (ADS)

    Diez, J. Javier; Veiga, Efren M.; Rodriguez, Fernando

    2015-04-01

    This work approaches the natural littoral processes and their changes induced by human activities around the Cantabrian RIA of FOZ (Galicia, NW Spain). Ria is a specific Spanish term for referring the estuary figured on the sea flooded mouth of a river valley. Although located in Galicia the RIA of FOZ is a Cantabrian Ria. The "Cantabrian rias" clearly differ from the "Galician rias" in their lower degree of tectonic complexity, in their smaller dimensions and in their more advanced current state of infilling (Diez, 1996). While Galician is a Pacific coast Cantabrian was generated as a mainly Atlantic coast. The sedimentary deposits of the Cantabrian rias are mainly from marine origin, being from fluvial origin (Asensio, 1979) just the finest components. The predominant Cantabrian littoral transport goes eastwards and, as consequence of it, the sedimentary littoral spits closing the mouths in coasts normally grow in the same sense. But there are many cases, like in the Ria of Foz, where the spit progresses in an apparent westwards atypical way. This work shows that it is due to combined wind wave phenomena of refraction, diffraction and reflection, which will be detailed. But the human activities interfere in these natural processes. Different port constructions have been made in the Ria of Foz from 1931 to 1977. Their final effects in the morph-dynamics obligate to introduce one construction for regenerate the spit in 1986. The performance, effectiveness and impact of all these port constructions are studied in detail and what are their influences in natural processes for finally applying this knowledge in risks management. Keywords: Rias, Littoral processes, Coastal morph-dynamics, Human induced driving, Risk management.

  15. [Analysis of the dilution deviation in CA19-9 measurement].

    PubMed

    Hanada, Hiroyuki; Takeoka, Keiko; Nomura, Tomoko; Moriyama, Takanori; Kanakura, Yuzuru

    2005-04-01

    CA19-9 widely used as a tumor marker of the pancreas and a bile duct. There are a number of reports which describes the measured value discrepancies between RIA and non-RIA kits. RIA results also have shown lack of the linearity over 70 U/ml when the samples are diluted. The pH condition at assay reaction for RIA had been suggested as the major reason, it has been denied by the results from the same pH condition at assay reaction used by COBAS CORE CA19-9 EIA II. On the other hand, the lack of RIA antibody titer is indicated for the discordant results by changing the sample volume to reagent volume ratio in the reaction. Our further investigation also indicates that the specific Lewis blood type, i.e. Le (a-b+), shows the linearity issues by RIA. The discrepancies are not caused by the reaction pH, but the amount of the antibody used in the RIA kit is closely associated. Considering the CA19-9 antibody nature used in RIA kit, which covers broad molecular range, users need to pay more attention to setting up each laboratory's measuring range.

  16. RIA fractions contain mesenchymal stroma cells with high osteogenic potency.

    PubMed

    Kuehlfluck, Pamela; Moghaddam, Arash; Helbig, Lars; Child, Christopher; Wildemann, Britt; Schmidmaier, Gerhard

    2015-12-01

    The gold standard for treatment of non-union is the transplantation of autologous bone from iliac crest. As an alternative, material can be harvested by femoral reaming with the Reamer-Irrigator-Aspirator(®) (RIA)-System. This material might be a source for human mesenchymal stroma cells (MSCs) with osteogenic potency. The aim of this study was the characterisation of cells harvested with the RIA system and the comparison of their properties with cells isolated from bone marrow ("BM") and fat tissue ("adipose"). The RIA material was separated into the liquid aspiration fraction ("liquid") and the solid RIA fraction. From the solid RIA fraction the cells were cultured either directly ("native") or after collagenase digestion and filtration ("filtrate"). Stem cell characteristics were analysed and the osteogenic potential was investigated in vitro and in vivo. Fat tissue and bone marrow were harvested from nine patients (three women, six males, with a mean of 48.1 years) with atrophic non-union RIA material. The cells were isolated and characterised by flow cytometry, three lineage differentiation capacities and colony-forming unit fibroblast assay. Gene expression profiles were performed and osteogenic differentiation in vivo was analysed. All three RIA fractions contained mesenchymal stromal cells (MSCs) as demonstrated by CFU-F assay, three linage differentiation and surface marker analysis. The RIA-MSCs exhibited a significantly higher osteogenic potential in vitro compared to adipose-MSCs, whereas no difference was seen compared to BM-MSCs. Quantitative RT-PCR analysis revealed an expression of osteogenic markers in all isolated cells. The implantation of MSCs with β-TCP scaffolds into the mice muscle showed significantly higher bone formation for the filtrate RIA-MSC, native RIA-MSC and BM-MSC groups compared to the adipose-MSC group. The filtrate RIA-MSCs formed twice as much new bone in vivo compared to BM-MSCs. The present study showed high potency of cells isolated by reaming. Even in the irrigation fluid, which is normally discarded, cells with the characteristics of stromal stem cells were isolated. In comparison to adipose-MSCs and BM-MSCs, the RIA-MSCs showed a similar or even better osteogenic potential in vitro and in vivo and this supports their usability in orthopaedic surgery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Convergent Validity of the Reynolds Intellectual Assessment Scales (RIAS) Using the Woodcock-Johnson Tests of Cognitive Ability, Third Edition (WJ-III) with University Students

    ERIC Educational Resources Information Center

    Krach, S. Kathleen; Loe, Scott A.; Jones, W. Paul; Farrally, Autumn

    2009-01-01

    Validity studies with the Reynolds Intellectual Ability scales (RIAS) indicated that RIAS composite intelligence index (CIX) and verbal intelligence index (VIX) scores have moderate-to-high correlation with comparable scores on other instruments. The authors of the RIAS described the VIX scale as a measure of crystallized ability and the nonverbal…

  18. Test Reviews: Reynolds, C. R., & Kamphaus, R. W. (2003). "RIAS: Reynolds Intellectual Assessment Scales." Lutz, FL: Psychological Assessment Resources, Inc.

    ERIC Educational Resources Information Center

    Andrews, Jac J. W.

    2007-01-01

    In this article, the author reviews the Reynolds Intellectual Assessment Scales (RIAS), an individually administered test of intelligence appropriate for ages 3 through 94 years with a conormed, supplemental measure of memory. The RIAS should be administered by examiners who have formal training in assessment. In this regard, the RIAS is a…

  19. RIA simulation tests using driver tube for ATF cladding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cinbiz, Mahmut N.; Brown, N. R.; Lowden, R. R.

    Pellet-cladding mechanical interaction (PCMI) is a potential failure mechanism for accident-tolerant fuel (ATF) cladding candidates during a reactivity-initiated accident (RIA). This report summarizes Fiscal Year (FY) 2017 research activities that were undertaken to evaluate the PCMI-like hoop-strain-driven mechanical response of ATF cladding candidates. To achieve various RIA-like conditions, a modified-burst test (MBT) device was developed to produce different mechanical pulses. The calibration of the MBT instrument was accomplished by performing mechanical tests on unirradiated Generation-I iron-chromium-aluminum (FeCrAl) alloy samples. Shakedown tests were also conducted in both FY 2016 and FY 2017 using unirradiated hydrided ZIRLO™ tube samples. This milestone reportmore » focuses on testing of ATF materials, but the benchmark tests with hydrided ZIRLO™ tube samples are documented in a recent journal article.a For the calibration and benchmark tests, the hoop strain was monitored using strain gauges attached to the sample surface in the hoop direction. A novel digital image correlation (DIC) system composed of a single high-speed camera and an array of six mirrors was developed for the MBT instrument to better resolve the failure behavior of samples and to provide useful data for validation of high-fidelity modeling and simulation tools. The DIC system enable a 360° view of a sample’s outer surface. This feature was added to the instrument to determine the precise failure location on a sample’s surface for strain predictions. The DIC system was tested on several silicon carbide fiber/silicon carbide matrix (SiC/SiC) composite tube samples at various pressurization rates of the driver tube (which correspond to the strain rates for the samples). The hoop strains for various loading conditions were determined for the SiC/SiC composite tube samples. Future work is planned to enhance understanding of the failure behavior of the ATF cladding candidates of age-hardened FeCrAl alloys and SiC/SiC composites in detail during RIA conditions informed by the computational studies performed under the US Department of Energy Office of Nuclear Energy Advanced Fuels Campaign. The testing instrument and the new DIC system will be further developed to reach different stress-state conditions and to perform tests at elevated temperatures.« less

  20. miRiaD: A Text Mining Tool for Detecting Associations of microRNAs with Diseases.

    PubMed

    Gupta, Samir; Ross, Karen E; Tudor, Catalina O; Wu, Cathy H; Schmidt, Carl J; Vijay-Shanker, K

    2016-04-29

    MicroRNAs are increasingly being appreciated as critical players in human diseases, and questions concerning the role of microRNAs arise in many areas of biomedical research. There are several manually curated databases of microRNA-disease associations gathered from the biomedical literature; however, it is difficult for curators of these databases to keep up with the explosion of publications in the microRNA-disease field. Moreover, automated literature mining tools that assist manual curation of microRNA-disease associations currently capture only one microRNA property (expression) in the context of one disease (cancer). Thus, there is a clear need to develop more sophisticated automated literature mining tools that capture a variety of microRNA properties and relations in the context of multiple diseases to provide researchers with fast access to the most recent published information and to streamline and accelerate manual curation. We have developed miRiaD (microRNAs in association with Disease), a text-mining tool that automatically extracts associations between microRNAs and diseases from the literature. These associations are often not directly linked, and the intermediate relations are often highly informative for the biomedical researcher. Thus, miRiaD extracts the miR-disease pairs together with an explanation for their association. We also developed a procedure that assigns scores to sentences, marking their informativeness, based on the microRNA-disease relation observed within the sentence. miRiaD was applied to the entire Medline corpus, identifying 8301 PMIDs with miR-disease associations. These abstracts and the miR-disease associations are available for browsing at http://biotm.cis.udel.edu/miRiaD . We evaluated the recall and precision of miRiaD with respect to information of high interest to public microRNA-disease database curators (expression and target gene associations), obtaining a recall of 88.46-90.78. When we expanded the evaluation to include sentences with a wide range of microRNA-disease information that may be of interest to biomedical researchers, miRiaD also performed very well with a F-score of 89.4. The informativeness ranking of sentences was evaluated in terms of nDCG (0.977) and correlation metrics (0.678-0.727) when compared to an annotator's ranked list. miRiaD, a high performance system that can capture a wide variety of microRNA-disease related information, extends beyond the scope of existing microRNA-disease resources. It can be incorporated into manual curation pipelines and serve as a resource for biomedical researchers interested in the role of microRNAs in disease. In our ongoing work we are developing an improved miRiaD web interface that will facilitate complex queries about microRNA-disease relationships, such as "In what diseases does microRNA regulation of apoptosis play a role?" or "Is there overlap in the sets of genes targeted by microRNAs in different types of dementia?"."

  1. Nuclear safety. Technical progress journal, October 1996--December 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The five papers in this issue address various issues associated with the behavior of high burnup fuels, especially under reactivity initiated accident (RIA) conditions. The mechanisms and parameters that have an effect on the fuel behavior are detailed, based on tests and analyses. The ultimate goal of the research reported is the development of new regulatory criteria for high burnup fuel under design basis accident conditions. Specific topics of the papers, which are abstracted individually in the database, are: (1) regulatory assessment of test data for RIAs, (2) high burnup fuel transient behavior under RIA conditions, (3) NSRR/RIA experiments withmore » high burnup PWR fuels, (4) the Russian RIA research program, and (5) RIA simulation experiments on the intermediate and high burnup test rods. The papers are contributed from the United States, France, Japan, and Russia.« less

  2. Impacts of urban wastewater discharge on seagrass meadows ( Zostera noltii)

    NASA Astrophysics Data System (ADS)

    Cabaço, Susana; Machás, Raquel; Vieira, Vasco; Santos, Rui

    2008-06-01

    The abiotic disturbance of urban wastewater discharge and its effects in the population structure, plant morphology, leaf nutrient content, epiphyte load and macroalgae abundance of Zostera noltii meadows were investigated in Ria Formosa coastal lagoon, southern Portugal using both univariate and multivariate analysis. Four sites were assessed, on a seasonal basis, along a gradient from a major Waste Water Treatment Works (WWTW) discharge to a main navigation channel. The wastewater discharge caused an evident environmental disturbance through the nutrient enrichment of the water and sediment, particularly of ammonium. Zostera noltii of the sites closest to the nutrient source showed higher leaf N content, clearly reflecting the nitrogen load. The anthropogenic nutrient enrichment resulted in higher biomass, and higher leaf and internode length, except for the meadow closest to the wastewater discharge (270 m). The high ammonium concentration (158-663 μM) in the water at this site resulted in the decrease of biomass, and both the leaf and internode length, suggesting a toxic effect on Z. noltii. The higher abundance of macroalgae and epiphytes found in the meadow closest to the nutrient source may also affect the species negatively. Shoot density was higher at the nutrient-undisturbed site. Two of the three abiotic processes revealed by Principal Component Analysis were clearly related to the WWTW discharge, a contrast between water column salinity and nutrient concentration and a sediment contrast between both porewater nutrients and temperature and redox potential. A multiple regression analysis showed that these abiotic processes had a significant effect on the biomass-density dynamics of meadows and on the overall size of Z. noltii plants, respectively. Results show that the wastewater discharge is an important source of environmental disturbance and nutrients availability in Ria Formosa lagoon affecting the population structure, morphology and N content of Z. noltii. This impact is spatially restricted to areas up to 600 m distant from the WWTW discharge, probably due to the high water renewal of the lagoon.

  3. Subconjunctivally Implanted Hydrogels for Sustained Insulin Release to Reduce Retinal Cell Apoptosis in Diabetic Rats.

    PubMed

    Imai, Hisanori; Misra, Gauri P; Wu, Linfeng; Janagam, Dileep R; Gardner, Thomas W; Lowe, Tao L

    2015-12-01

    Diabetic retinopathy (DR) is a leading cause of blindness in diabetic patients that involves early-onset retinal cell loss. Here, we report our recent work using subconjunctivally implantable hydrogels for sustained insulin release to the retina to prevent retinal degeneration. The hydrogels are synthesized by UV photopolymerization of N-isopropylacrylamide and a dextran macromer containing oligolactate-(2-hydroxyetheyl methacrylate) units. Insulin was loaded into the hydrogels during the synthesis. The ex vivo bioactivity of insulin released from the hydrogels was tested on fresh rat retinas using immunoprecipitation and immunoblotting to measure insulin receptor tyrosine and Akt phosphorylation. The biosafety and the effect on the blood glucose of the hydrogels were evaluated in rats 2 months after subconjunctival implantation. The release of insulin from the hydrogels was studied both in vitro in PBS (pH 7.4), and in vivo using confocal microscopy and RIA kit. The in vivo bioactivity of the released insulin was investigated in diabetic rats using DNA fragmentation method. The hydrogels could load insulin with approximately 98% encapsulation efficiency and continuously release FITC-insulin in PBS (pH = 7.4) at 37°C for at least 5 months depending on their composition. Insulin lispro released from the hydrogels was biologically active by increasing insulin receptor tyrosine and Akt serine phosphorylation of ex vivo retinas. In vivo studies showed normal retinal histology 2 months post subconjunctival implantation. Insulin released from subconjunctivally implanted hydrogels could be detected in the retina by using confocal microscopy and RIA kit for 1 week. The implanted hydrogels with insulin lispro did not change the blood glucose level of normal and diabetic rats, but significantly reduced the DNA fragmentation of diabetic retinas for 1 week. The developed hydrogels have great potential to sustain release of insulin to the retina via subconjunctival implantation to minimize DR without the risk of hypoglycemia.

  4. Subconjunctivally Implanted Hydrogels for Sustained Insulin Release to Reduce Retinal Cell Apoptosis in Diabetic Rats

    PubMed Central

    Imai, Hisanori; Misra, Gauri P.; Wu, Linfeng; Janagam, Dileep R.; Gardner, Thomas W.; Lowe, Tao L.

    2015-01-01

    Purpose Diabetic retinopathy (DR) is a leading cause of blindness in diabetic patients that involves early-onset retinal cell loss. Here, we report our recent work using subconjunctivally implantable hydrogels for sustained insulin release to the retina to prevent retinal degeneration. Methods The hydrogels are synthesized by UV photopolymerization of N-isopropylacrylamide and a dextran macromer containing oligolactate-(2-hydroxyetheyl methacrylate) units. Insulin was loaded into the hydrogels during the synthesis. The ex vivo bioactivity of insulin released from the hydrogels was tested on fresh rat retinas using immunoprecipitation and immunoblotting to measure insulin receptor tyrosine and Akt phosphorylation. The biosafety and the effect on the blood glucose of the hydrogels were evaluated in rats 2 months after subconjunctival implantation. The release of insulin from the hydrogels was studied both in vitro in PBS (pH 7.4), and in vivo using confocal microscopy and RIA kit. The in vivo bioactivity of the released insulin was investigated in diabetic rats using DNA fragmentation method. Results The hydrogels could load insulin with approximately 98% encapsulation efficiency and continuously release FITC-insulin in PBS (pH = 7.4) at 37°C for at least 5 months depending on their composition. Insulin lispro released from the hydrogels was biologically active by increasing insulin receptor tyrosine and Akt serine phosphorylation of ex vivo retinas. In vivo studies showed normal retinal histology 2 months post subconjunctival implantation. Insulin released from subconjunctivally implanted hydrogels could be detected in the retina by using confocal microscopy and RIA kit for 1 week. The implanted hydrogels with insulin lispro did not change the blood glucose level of normal and diabetic rats, but significantly reduced the DNA fragmentation of diabetic retinas for 1 week. Conclusions The developed hydrogels have great potential to sustain release of insulin to the retina via subconjunctival implantation to minimize DR without the risk of hypoglycemia. PMID:26658505

  5. Evaluation of EMIT and RIA high volume test procedures for THC metabolites in urine utilizing GC/MS confirmation.

    PubMed

    Abercrombie, M L; Jewell, J S

    1986-01-01

    Results of EMIT, Abuscreen RIA, and GC/MS tests for THC metabolites in a high volume random urinalysis program are compared. Samples were field tested by non-laboratory personnel with an EMIT system using a 100 ng/mL cutoff. Samples were then sent to the Army Forensic Toxicology Drug Testing Laboratory (WRAMC) at Fort Meade, Maryland, where they were tested by RIA (Abuscreen) using a statistical 100 ng/mL cutoff. Confirmations of all RIA positives were accomplished using a GC/MS procedure. EMIT and RIA results agreed for 91% of samples. Data indicated a 4% false positive rate and a 10% false negative rate for EMIT field testing. In a related study, results for samples which tested positive by RIA for THC metabolites using a statistical 100 ng/mL cutoff were compared with results by GC/MS utilizing a 20 ng/mL cutoff for the THCA metabolite. Presence of THCA metabolite was detected in 99.7% of RIA positive samples. No relationship between quantitations determined by the two tests was found.

  6. Foraminiferal biotopes and their distribution control in Ria de Aveiro (Portugal): a multiproxy approach.

    PubMed

    Martins, Maria Virgínia Alves; Frontalini, Fabrizio; Laut, Lazaro L M; Silva, Frederico S; Moreno, João; Sousa, Silvia; Zaaboub, Noureddine; El Bour, Monia; Rocha, Fernando

    2014-12-01

    Ria de Aveiro, which is located in the centre of Portugal (40° 38' N, 8° 45' W), is a well-mixed and complex coastal lagoon that is separated from the sea by a sandy barrier and connects with the Atlantic through an artificial inlet. Tidal currents are the main factor controlling the lagoon's hydrodynamics and, to a great extent, the sedimentary dynamic. The inner lagoonal zones receive input from several rivers and experience the pressure caused by the accumulation of organic matter and pollutants (namely, trace metals) from diverse anthropic activities. This paper is the first piece of work aiming to recognize, characterize and explain the main benthic foraminiferal biotopes in Ria de Aveiro. To provide a broad overview of this kind of setting, our results are compared to those of previous published studies conducted in similar transitional environments. The research is based on an investigation of 225 sites spread throughout this ecosystem. Utilizing a statistical approach, this study analyses the details of dead benthic foraminiferal assemblages composed of 260 taxa, the texture and composition (mineralogical and geochemical) of the sediment and physicochemical data. On the basis of the results of R-mode and Q-mode cluster analyses, several different biotopes can be defined as marsh biotope/near-marsh biotope; marginal urban/marginal urban mixing biotope; inner-outer lagoon biotope or enclosed lagoon; outer lagoon biotope, mixed sub-biotope; and outer lagoon, marine sub-biotope. These biotopes are related to foraminifera assemblages and substrate type and are influenced by local currents, water depth, chemical and physicochemical conditions, river or oceanic proximity, and anthropogenic impact, as evidenced by the mapping of the six factor loadings of the principal component analysis conducted herein. Based on a similar methodology of analysis as that applied in previous studies in the Lagoon of Venice, comparable biotypes were identified in Lagoon of Aveiro.

  7. Remote Infrared Audible Signage (RIAS) Pilot Program : evaluation report

    DOT National Transportation Integrated Search

    2009-09-01

    This report presents evaluation findings on the Remote Infrared Audible Signage (RIAS) Pilot Program in the Puget Sound Region of Washington. The installation, demonstration and evaluation of RIAS were required by a provision in the Safe, Accountable...

  8. Coastal upwelling and downwelling forcing of circulation in a semi-enclosed bay: Ria de Vigo

    NASA Astrophysics Data System (ADS)

    Barton, E. D.; Largier, J. L.; Torres, R.; Sheridan, M.; Trasviña, A.; Souza, A.; Pazos, Y.; Valle-Levinson, A.

    2015-05-01

    Semi-enclosed bays in upwelling regions are exposed to forcing related to winds, currents and buoyancy over the shelf. The influence of this external forcing is moderated by factors such as connectivity to the open ocean, shelter by surrounding topography, dimensions of the bay, and freshwater outflows. Such bays, preferred locations for ports, mariculture, marine industry, recreational activities and coastal settlement, present a range of characteristics, understanding of which is necessary to their rational management. Observations in such a semi-enclosed bay, the Ria de Vigo in Spain, are used to characterize the influence of upwelling and downwelling pulses on its circulation. In this location, near the northern limit of the Iberian upwelling system, upwelling events dominate during a short summer season and downwelling events the rest of the year. The ria response to the external forcing is central to nutrient supply and resultant plankton productivity that supports its high level of cultured mussel production. Intensive field studies in September 2006 and June 2007 captured a downwelling event and an upwelling event, respectively. Data from eight current profiler moorings and boat-based MiniBat/ADCP surveys provided an unprecedented quasi-synoptic view of the distribution of water masses and circulation patterns in any ria. In the outer ria, circulation was dominated by the introduction of wind-driven alongshore flow from the external continental shelf through the ria entrances and its interaction with the topography. In the middle ria, circulation was primarily related to the upwelling/downwelling cycle, with a cool, salty and dense lower layer penetrating to the inner ria during upwelling over the shelf. A warmer, lower salinity and less dense surface layer of coastal waters flowed inward during downwelling. Without external forcing, the inner ria responded primarily to tides and buoyancy changes related to land runoff. Under both upwelling and downwelling conditions, the flushing of the ria involved shelf responses to wind pulses. Their persistence for a few days was sufficient to allow waters from the continental shelf to penetrate the innermost ria. Longer term observations supported by numerical modeling are required to confirm the generality of such flushing events in the ria and determine their typical frequency, while comparative studies should explore how these scenarios fit into the range of conditions experienced in other semi-enclosed bays.

  9. Astrophysics at RIA (ARIA) Working Group

    NASA Astrophysics Data System (ADS)

    Smith, Michael S.; Schatz, Hendrik; Timmes, Frank X.; Wiescher, Michael; Greife, Uwe

    2006-07-01

    The Astrophysics at RIA (ARIA) Working Group has been established to develop and promote the nuclear astrophysics research anticipated at the Rare Isotope Accelerator (RIA). RIA is a proposed next-generation nuclear science facility in the U.S. that will enable significant progress in studies of core collapse supernovae, thermonuclear supernovae, X-ray bursts, novae, and other astrophysical sites. Many of the topics addressed by the Working Group are relevant for the RIKEN RI Beam Factory, the planned GSI-Fair facility, and other advanced radioactive beam facilities.

  10. Magnetic resonance index of activity (MaRIA) and Clermont score are highly and equally effective MRI indices in detecting mucosal healing in Crohn's disease.

    PubMed

    Buisson, Anthony; Pereira, Bruno; Goutte, Marion; Reymond, Maud; Allimant, Christophe; Obritin-Guilhen, Hélène; Bommelaer, Gilles; Hordonneau, Constance

    2017-11-01

    Magnetic resonance index of activity (MaRIA) and Clermont score are currently the two main MRI indices that have been validated compared to endoscopy in Crohn's disease (CD). To compare the accuracy of MaRIA and Clermont score in assessing CD mucosal healing. Fourty-four CD patients underwent prospectively and consecutively MRI and colonoscopy. Considering 207 segments, MaRIA>7 and Clermont score>8.4 demonstrated substantial accuracy to detect endoscopic ulcerations (73.9% and 74.0%, respectively) and presented with high specificity (82.1% and 81.3%) and high negative predictive value (NPV) (82.1% and 82.4%) for MaRIA and Clermont score, respectively. The sensitivity for detecting deep ulcerations was 90.9% for both MaRIA>11 and Clermont score>12.5, with a specificity of 82.0% and 80.0%, respectively. Among 44 patients, deep MRI remission predicted mucosal healing with specificity=85.3% and NPV=85.3% according to Barcelona criteria (no segmental MaRIA>7), and specificity=88.2% and NPV=85.7% according to Clermont criteria (no segmental Clermont score>8.4). In addition, MRI remission predicted mucosal healing with specificity=76.5% and NPV=86.7% according to Barcelona criteria (no segmental MaRIA>11), and specificity=79.4% and NPV=84.4% according to Clermont criteria (no segmental Clermont score>12.5). MaRIA and Clermont score are equally effective in detecting CD endoscopic ulcerations supporting their use as therapeutic endpoints. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  11. Predicting Factors of Chronic Subdural Hematoma Following Surgical Clipping in Unruptured and Ruptured Intracranial Aneurysm.

    PubMed

    Kwon, Min-Yong; Kim, Chang-Hyun; Lee, Chang-Young

    2016-09-01

    The aim of this study is to analyze the differences in the incidence, predicting factors, and clinical course of chronic subdural hematoma (CSDH) following surgical clipping between unruptured (UIA) and ruptured intracranial aneurysm (RIA). We conducted a retrospective analysis of 752 patients (UIA : 368 and RIA : 384) who underwent surgical clipping during 8 years. The incidence and predicting factors of CSDH development in the UIA and RIA were compared according to medical records and radiological data. The incidence of postoperative CSDH was higher in the UIA (10.9%) than in the RIA (3.1%) (p=0.000). In multivariate analysis, a high Hounsfield (HF) unit (blood clots) for subdural fluid collection (SFC), persistence of SFC ≥5 mm and male sex in the UIA and A high HF unit for SFC and SFC ≥5 mm without progression to hydrocephalus in the RIA were identified as the independent predicting factors for CSDH development (p<0.05). There were differences in the incidence and predicting factors for CSDH following surgical clipping between UIA and RIA. Blood clots in the subdural space and persistence of SFC ≥5 mm were predicting factors in both UIA and RIA. However, progression to hydrocephalus may have in part contributed to low CSDH development in the RIA. We suggest that cleaning of blood clots in the subdural space and efforts to minimize SFC ≥5 mm at the end of surgery is helpful to prevent CSDH following aneurysmal clipping.

  12. Evaluation of the Coat-A-Count sup 125 I fentanyl RIA: Comparison of sup 12 5I RIA and GC/MS-SIM for quantification of fentanyl in case urine specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watts, V.W.; Caplan, Y.H.

    The Coat-A-Count solid phase {sup 125}I Fentanyl Radioimmunoassay was evaluated with respect to linearity and precision using equine urine fortified with fentanyl and then compared with a gas chromatographic/mass spectrometric method for quantification of fentanyl in urine. The RIA assay was found to be linear over the urine fentanyl concentration range of 0.25 to 7.5 ng/mL and precise with coefficients of variation (CV) ranging from 9.6 to 19.3%. The RIA calibrators, ranging in fentanyl concentrations from 0.25 to 7.5 ng/mL, and controls, at mean fentanyl concentrations of 0.46 and 1.32 ng/mL, were compared by both the RIA and GC/MS methods.more » The cross-reactivity with the {sup 125}I RIA test was determined for the fentanyl metabolites, norfentanyl and hydroxyfentanyl, and found to be 5% and 35%, respectively. The illicit fentanyl analogs were found to show significant cross-reactivity, ranging from 20 to 100%. The {sup 125}I RIA was compared to GC/MS quantifications of fentanyl in 35 positive and 20 negative case urine specimens.« less

  13. Predicting Factors of Chronic Subdural Hematoma Following Surgical Clipping in Unruptured and Ruptured Intracranial Aneurysm

    PubMed Central

    Kwon, Min-Yong; Kim, Chang-Hyun

    2016-01-01

    Objective The aim of this study is to analyze the differences in the incidence, predicting factors, and clinical course of chronic subdural hematoma (CSDH) following surgical clipping between unruptured (UIA) and ruptured intracranial aneurysm (RIA). Methods We conducted a retrospective analysis of 752 patients (UIA : 368 and RIA : 384) who underwent surgical clipping during 8 years. The incidence and predicting factors of CSDH development in the UIA and RIA were compared according to medical records and radiological data. Results The incidence of postoperative CSDH was higher in the UIA (10.9%) than in the RIA (3.1%) (p=0.000). In multivariate analysis, a high Hounsfield (HF) unit (blood clots) for subdural fluid collection (SFC), persistence of SFC ≥5 mm and male sex in the UIA and A high HF unit for SFC and SFC ≥5 mm without progression to hydrocephalus in the RIA were identified as the independent predicting factors for CSDH development (p<0.05). Conclusion There were differences in the incidence and predicting factors for CSDH following surgical clipping between UIA and RIA. Blood clots in the subdural space and persistence of SFC ≥5 mm were predicting factors in both UIA and RIA. However, progression to hydrocephalus may have in part contributed to low CSDH development in the RIA. We suggest that cleaning of blood clots in the subdural space and efforts to minimize SFC ≥5 mm at the end of surgery is helpful to prevent CSDH following aneurysmal clipping. PMID:27651863

  14. An Exploratory Investigation of the Factor Structure of the Reynolds Intellectual Assessment Scales (RIAS)

    ERIC Educational Resources Information Center

    Dombrowski, Stefan C.; Watkins, Marley W.; Brogan, Michael J.

    2009-01-01

    This study investigated the factor structure of the Reynolds Intellectual Assessment Scales (RIAS) using rigorous exploratory factor analytic and factor extraction procedures. The results of this study indicate that the RIAS is a single factor test. Despite these results, higher order factor analysis using the Schmid-Leiman procedure indicates…

  15. Comparison of EMIT II, CEDIA, and DPC RIA assays for the detection of lysergic acid diethylamide in forensic urine samples.

    PubMed

    Wiegand, Russell F; Klette, Kevin L; Stout, Peter R; Gehlhausen, Jay M

    2002-10-01

    In an effort to determine a practical, efficient, and economical alternative for the use of a radioimmunoassay (RIA) for the detection of lysergic acid diethylamide (LSD) in human urine, the performance of two photometric immunoassays (Dade Behring EMIT II and Microgenics CEDIA) and the Diagnostics Products Corp. (DPC) RIA were compared. Precision, accuracy, and linearity of the 3 assays were determined by testing 60 replicates (10 for RIA) at 5 different concentrations below and above the 500-pg/mL LSD cut-off. The CEDIA and RIA exhibited better accuracy and precision than the EMIT II immunoassay. In contrast, the EMIT II and CEDIA demonstrated superior linearity r2 = 0.9809 and 0.9540, respectively, as compared with the RIA (r2 = 0.9062). The specificity of the three assays was assessed using compounds that have structural and chemical properties similar to LSD, common over-the-counter products, prescription drugs and some of their metabolites, and other drugs of abuse. Of the 144 compounds studied, the EMIT II cross-reacted with twice as many compounds as did the CEDIA and RIA. Specificity was also assessed in 221 forensic human urine specimens that previously screened positive for LSD by the EMIT II assay. Of these, only 11 tested positive by CEDIA, and 3 were positive by RIA. This indicated a comparable specificity performance between CEDIA and RIA. This also was consistent with a previously reported high false-positive rate of EMIT II (low specificity). Each of the immunoassays correctly identified LSD in 23 out of 24 human urine specimens that had previously been found to contain LSD by gas chromatography-mass spectrometry at a cut-off concentration of 200 pg/mL. The CEDIA exhibited superior precision, accuracy, and decreased cross-reactivity to compounds other than LSD as compared with the EMIT II assay and does not necessitate the handling of radioactive materials.

  16. Diaphragmatic mobility: relationship with lung function, respiratory muscle strength, dyspnea, and physical activity in daily life in patients with COPD.

    PubMed

    Rocha, Flávia Roberta; Brüggemann, Ana Karla Vieira; Francisco, Davi de Souza; Medeiros, Caroline Semprebom de; Rosal, Danielle; Paulin, Elaine

    2017-01-01

    To evaluate diaphragmatic mobility in relation to lung function, respiratory muscle strength, dyspnea, and physical activity in daily life (PADL) in patients with COPD. We included 25 patients with COPD, classified according to the Global Initiative for Chronic Obstructive Lung Disease criteria, and 25 healthy individuals. For all of the participants, the following were evaluated: anthropometric variables, spirometric parameters, respiratory muscle strength, diaphragmatic mobility (by X-ray), PADL, and the perception of dyspnea. In the COPD group, diaphragmatic mobility was found to correlate with lung function variables, inspiratory muscle strength, and the perception of dyspnea, whereas it did not correlate with expiratory muscle strength or PADL. In patients with COPD, diaphragmatic mobility seems to be associated with airway obstruction and lung hyperinflation, as well as with ventilatory capacity and the perception of dyspnea, although not with PADL. Avaliar a relação da mobilidade diafragmática com a função pulmonar, força muscular respiratória, dispneia e atividade física de vida diária (AFVD) em pacientes com DPOC. Foram avaliados 25 pacientes com diagnóstico de DPOC, classificados de acordo com critérios da Global Initiative for Chronic Obstructive Lung Disease, e 25 indivíduos saudáveis. Todos foram submetidos às seguintes avaliações: mensuração antropométrica, espirometria, força muscular respiratória, mobilidade diafragmática (por radiografia), AFVD e percepção de dispneia. No grupo DPOC, houve correlações da mobilidade diafragmática com variáveis de função pulmonar, força muscular inspiratória e percepção de dispneia. Não houve correlações da mobilidade diafragmática com força muscular expiratória e AFVD. A mobilidade diafragmática parece estar associada tanto com a obstrução das vias aéreas quanto com a hiperinsuflação pulmonar em pacientes com DPOC, assim como com a capacidade ventilatória e percepção de dispneia, mas não com AFVD.

  17. Hypothyroidism following treatment for head and neck cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vrabec, D.P.; Heffron, T.J.

    One hundred ninety-six head and neck patients were studied to determine the effects of radiation therapy and surgery on thyroid function. Serum thyroid-stimulating hormone (TSH) levels were obtained as a screening test for primary hypothyroidism. Elevated TSH levels were found in 57 of the 196 patients (29.1%). The highest incidence of abnormal TSH values (66%) occurred in the group treated with combination radiation therapy and surgery, including partial thyroidectomy. TSH levels rose early in the posttreatment period with 60% of the abnormal values occurring within the first three posttreatment years. Posttreatment thyroid dysfunction was twice as common in women (48.6%)more » as in men (25.4%). When serum thyroxine levels by radioimmunoassay (T4RIA) were correlated with the elevated serum TSH levels, a similar pattern was seen with 65% of the patients in Group 3 having a decreased T4RIA level indicating overt hypothyroidism. Pretreatment levels of thyroid function including thyroid antibody studies should be established for all patients. Serial TSH levels should be done every three months during the first three posttreatment years and semiannually thereafter as long as the patient will return for follow-up care. All patients treated with combination radiation therapy and surgery who develop elevated TSH levels should be treated with thyroid replacement therapy. Patients receiving radiation therapy alone should receive replacement thyroid therapy if they develop a depressed T4RIA value or a pattern of gradually increasing TSH levels.« less

  18. Influence of the Minho River plume on the Rias Baixas (NW of the Iberian Peninsula)

    NASA Astrophysics Data System (ADS)

    Sousa, M. C.; Vaz, N.; Alvarez, I.; Gomez-Gesteira, M.; Dias, J. M.

    2014-11-01

    The buoyancy generated by the Minho estuarine plume can flood the Rias Baixas for long periods, reversing the normal salinity gradients. Thus, the main purpose of this work was to study the propagation of Minho estuarine plume to the Rias Baixas, establishing the wind and river discharge conditions in which this plume affects the circulation and hydrography features of these coastal systems as well as the plume characteristics under the most probable forcing conditions, through the application of the numerical model MOHID. For this purpose, several scenarios with different river discharges and wind were simulated. The numerical results revealed that the Minho estuarine plume responds rapidly to wind variations and is influenced by coastline geometry. Under Minho River discharges higher than 700 m3 s- 1 and weak northward winds (3 m s- 1) the circulation patterns of the Rias de Vigo and Pontevedra are reversed. On the other hand, moderate northward winds (6 m s- 1) combined with Minho River discharges higher than 200 m3 s- 1, 300 m3 s- 1 and 700 m3 s- 1 reverse the circulation pattern of the Rias de Vigo, Pontevedra and Arousa, respectively. Under the same conditions, the water exchange between Rias Baixas was analyzed using a particle-tracking model following the trajectories of particles released close to the Minho River mouth. Over 5 days, under Minho River discharges higher than 2100 m3 s- 1 combined with northward winds of 6 m s- 1, an intense water exchange between Rias was observed. However, only 20% of the particles found in Ria de Pontevedra come directly from the Minho River.

  19. Splenic artery aneurysm.

    PubMed

    Tcbc-Rj, Rui Antônio Ferreira; Ferreira, Myriam Christina Lopes; Ferreira, Daniel Antônio Lopes; Ferreira, André Gustavo Lopes; Ramos, Flávia Oliveira

    2016-01-01

    Splenic artery aneurysms - the most common visceral artery aneurysms - are found most often in multiparous women and in patients with portal hypertension. Indications for treatment of splenic artery aneurysm or pseudoaneurysm include specific symptoms, female gender and childbearing age, presence of portal hypertension, planned liver transplantation, a pseudoaneurysm of any size, and an aneurysm with a diameter of more than 2.5cm. Historically, the treatment of splenic artery aneurysm has been surgical ligation of the splenic artery, ligation of the aneurysm, or aneurysmectomy with or without splenectomy, depending on the aneurysm location. There are other percutaneous interventional techniques. The authors present a case of a splenic artery aneurysm in a 51-year-old woman, detected incidentally. RESUMO Aneurismas da artéria esplênica - os aneurismas arteriais viscerais mais comuns - são encontrados mais frequentemente em mulheres multíparas e em pacientes com hipertensão portal. As indicações para o seu tratamento incluem sintomas específicos, sexo feminino e idade fértil, presença de hipertensão portal, paciente em fila de transplante hepático, um pseudoaneurisma de qualquer tamanho, e um aneurisma com um diâmetro superior a 2,5cm. Historicamente, o tratamento do aneurisma da artéria esplênica tem sido a ligadura cirúrgica da artéria esplênica, a ligadura do aneurisma ou a aneurismectomia, com ou sem esplenectomia, dependendo do local do aneurisma. Existem outras técnicas intervencionistas percutâneas. Os autores apresentam o caso de um aneurisma de artéria esplênica em uma mulher de 51 anos de idade, diagnosticado incidentalmente.

  20. Assessment of pharmacy students' communication competence using the Roter Interaction Analysis System during objective structured clinical examinations.

    PubMed

    Kubota, Yoshie; Yano, Yoshitaka; Seki, Susumu; Takada, Kaori; Sakuma, Mio; Morimoto, Takeshi; Akaike, Akinori; Hiraide, Atsushi

    2011-04-11

    To determine the value of using the Roter Interaction Analysis System during objective structured clinical examinations (OSCEs) to assess pharmacy students' communication competence. As pharmacy students completed a clinical OSCE involving an interview with a simulated patient, 3 experts used a global rating scale to assess students' overall performance in the interview, and both the student's and patient's languages were coded using the Roter Interaction Analysis System (RIAS). The coders recorded the number of utterances (ie, units of spoken language) in each RIAS category. Correlations between the raters' scores and the number and types of utterances were examined. There was a significant correlation between students' global rating scores on the OSCE and the number of utterances in the RIAS socio-emotional category but not the RIAS business category. The RIAS proved to be a useful tool for assessing the socio-emotional aspect of students' interview skills.

  1. An Operational Coastal Forecasting System in Galicia (NW Spain)

    NASA Astrophysics Data System (ADS)

    Balseiro, C. F.; Carracedo, P.; Pérez, E.; Pérez, V.; Taboada, J.; Venacio, A.; Vilasa, L.

    2009-09-01

    The Galician coast (NW Iberian Peninsula coast) and mainly the Rias Baixas (southern Galician rias) are one of the most productive ecosystems in the world, supporting a very active fishing and aquiculture industry. This high productivity lives together with a high human pressure and an intense maritime traffic, which means an important environmental risk. Besides that, Harmful Algae Blooms (HAB) are common in this area, producing important economical losses in aquiculture. In this context, the development of an Operational Hydrodynamic Ocean Forecast System is the first step to the development of a more sophisticated Ocean Integrated Decision Support Tool. A regional oceanographic forecasting system in the Galician Coast has been developed by MeteoGalicia (the Galician regional meteorological agency) inside ESEOO project to provide forecasts on currents, sea level, water temperature and salinity. This system is based on hydrodynamic model MOHID, forced with the operational meteorological model WRF, supported daily at MeteoGalicia . Two grid meshes are running nested at different scales, one of ~2km at the shelf scale and the other one with a resolution of 500 m at the rias scale. ESEOAT (Puertos del Estado) model provide salinity and temperature fields which are relaxed at all depth along the open boundary of the regional model (~6km). Temperature and salinity initial fields are also obtained from this application. Freshwater input from main rivers are included as forcing in MOHID model. Monthly mean discharge data from gauge station have been provided by Aguas de Galicia. Nowadays a coupling between an hydrological model (SWAT) and the hydrodynamic one are in development with the aim to verify the impact of the rivers discharges. The system runs operationally daily, providing two days of forecast. First model verifications had been performed against Puertos del Estado buoys and Xunta de Galicia buoys network along the Galician coast. High resolution model results were validated against a CTDs profiles campaign carried out during an oil spill exercise in the Ria de Vigo in April 2007. During EROCIPS INTERREG IIIB and EASY INTERREG IVB projects, a Galician oceanographic observation network were built. Three stations located inside the Rias Baixas allow to collect meteorological and oceanographic data at different depths to calibrate and validate the modelization of the rias. To complete this network and to create a common data platform a new project emerged (RAIA INTERREG IVA). It will provide MeteoGalicia more scientific data to improve the study of the rias. Furthermore, MeteoGalicia is also involved in DRIFTER AMPERA project which allows to improve the capability of modelling and monitoring the trajectory of hazardous substances and inerts.

  2. Test Review: Reynolds, C. R., & Kamphaus, R. W. (2003). "RIAS--Reynolds Intellectual Assessment Scales." Lutz, FL--Psychological Assessment Resources, Inc.

    ERIC Educational Resources Information Center

    Dombrowski, Stefan C.; Mrazik, Martin

    2008-01-01

    In this article, the authors review the Reynolds Intellectual Assessment Scales (RIAS; Reynolds & Kamphaus, 2003), an individually administered test of intelligence for use with individuals between the ages of 3 and 94. The RIAS represents the newest intelligence test on the marketplace and incorporates the most current intelligence test theory…

  3. Examination of the Structural, Convergent, and Incremental Validity of the Reynolds Intellectual Assessment Scales (RIAS) with a Clinical Sample

    ERIC Educational Resources Information Center

    Nelson, Jason M.; Canivez, Gary L.

    2012-01-01

    Empirical examination of the Reynolds Intellectual Assessment Scales (RIAS; C. R. Reynolds & R. W. Kamphaus, 2003a) has produced mixed results regarding its internal structure and convergent validity. Various aspects of validity of RIAS scores with a sample (N = 521) of adolescents and adults seeking psychological evaluations at a university-based…

  4. Measurement Invariance and Latent Mean Differences in the Reynolds Intellectual Assessment Scales (RIAS): Does the German Version of the RIAS Allow a Valid Assessment of Individuals with a Migration Background?

    PubMed Central

    Gygi, Jasmin T.; Fux, Elodie; Grob, Alexander; Hagmann-von Arx, Priska

    2016-01-01

    This study examined measurement invariance and latent mean differences in the German version of the Reynolds Intellectual Assessment Scales (RIAS) for 316 individuals with a migration background (defined as speaking German as a second language) and 316 sex- and age-matched natives. The RIAS measures general intelligence (single-factor structure) and its two components, verbal and nonverbal intelligence (two-factor structure). Results of a multi-group confirmatory factor analysis showed scalar invariance for the two-factor and partial scalar invariance for the single-factor structure. We conclude that the two-factor structure of the RIAS is comparable across groups. Hence, verbal and nonverbal intelligence but not general intelligence should be considered when comparing RIAS test results of individuals with and without a migration background. Further, latent mean differences especially on the verbal, but also on the nonverbal intelligence index indicate language barriers for individuals with a migration background, as subtests corresponding to verbal intelligence require higher skills in German language. Moreover, cultural, environmental, and social factors that have to be taken into account when assessing individuals with a migration background are discussed. PMID:27846270

  5. Damage of tracer erythropoietin results in erroneous estimation of concentration in mouse submaxillary gland.

    PubMed

    Vidal, A; Carcagno, M; Criscuolo, M; Barcelò, A C; Alippi, R M; Leal, T; Bozzini, C E

    1993-02-01

    It has been previously reported that 1) plasma erythropoietin (Epo) titer during exposure to hypobaria is lower in nephrectomized rats and mice whose submaxillary glands (SMG) were either ablated or atrophied than in nephrectomized controls whose SMG were intact and 2) that the gland shows one of the highest levels of immunoreactive Epo (iEpo) in the body. The latter observation, however, was questioned recently when it was observed that SMG extracts degrade labeled Epo used as tracer antigen in the radioimmunoassay (RIA), thus giving invalid estimates of Epo. Since this interpretation was in turn questioned, the present study was conducted to obtain more information on the subject and make these conflicting points clear. Investigation of the reported/possible degradation of Epo by SMG homogenates was conducted via polyacrylamide gel electrophoresis followed by radioautography or by a RIA in solid phase in which there was no simultaneous incubation of the tracer antigen with the SMG homogenates. It was observed that 125I-labeled rhEpo was degraded when incubated with SMG homogenates. Degradation was rapid, being evident when incubation lasted 30 minutes, and occurred in the presence of a protease inhibitor. It showed a high degree of specificity since it did not occur when Epo was incubated with kidney homogenate or normal mouse serum. SMG homogenate did not degrade labeled thyrotrophic hormone and degraded alpha interferon (IFN-alpha) only partially. When estimates of iEpo in SMG homogenate were performed in conditions of simultaneous (SI-RIA) or nonsimultaneous (NSI-RIA) incubation of the homogenate with tracer Epo, it was observed that while estimates of Epo in plasma were similar in both types of RIA and somewhat higher in kidney homogenate in the SI-RIA than in the NSI-RIA, estimates of Epo in SMG were about 60 times higher in the former than in the latter. Therefore, it could be concluded that most of the Epo detected by standard RIA in SMG homogenate does not represent true Epo because of damage of tracer Epo which determines loss of the integrity of the RIA system.

  6. Magnetic Resonance Imaging Predicts Histopathological Composition of Ileal Crohn's Disease.

    PubMed

    Wagner, Mathilde; Ko, Huaibin Mabel; Chatterji, Manjil; Besa, Cecilia; Torres, Joana; Zhang, Xiaofei; Panchal, Hinaben; Hectors, Stefanie; Cho, Judy; Colombel, Jean-Frederic; Harpaz, Noam; Taouli, Bachir

    2018-05-25

    Recently, smooth muscle hypertrophy has been suggested to be a contributor to small bowel lesions secondary to Crohn's disease [CD], in addition to inflammation and fibrosis. Here, we assess the value of magnetic resonance imaging [MRI] for the characterisation of histopathological tissue composition of small bowel CD, including inflammation, fibrosis, and smooth muscle hypertrophy. A total of 35 consecutive patients [male/female 17/18, mean age 33 years] with ileal CD, who underwent small bowel resection and a preoperative contrast-enhanced MRI examination within 1 month before surgery, were retrospectively included. Image assessment included qualitative [pattern/degree of enhancement, presence of ulcerations/fistulas/abscesses] and quantitative parameters [wall thickness on T2/T1-weighted images [WI], enhancement ratios, apparent diffusion coefficient [ADC], Clermont and Magnetic Resonance Index of Activity [MaRIA] scores). MRI parameters were compared with histopathological findings including active inflammation, collagen deposition, and muscle hypertrophy using chi square/Fisher or Mann-Whitney tests and univariate/multivariate logistic/linear regression analyses. Forty ileal segments were analysed in 35 patients. Layered pattern at early-post-contrast phase was more prevalent (odds ratio [OR] = 8; p = 0.008), ADC was significantly lower [OR = 0.005; p = 0.022], and MaRIA score was significantly higher [OR = 1.125; p = 0.022] in inflammation grades 2-3 compared with grade 1. Wall thickness on T2WI was significantly increased [OR = 1.688; p = 0.043], and fistulas [OR = 14.5; p = 0.017] were more prevalent in segments with disproportionately increased muscle hypertrophy versus those with disproportionately increased fibrosis. MaRIA/Clermont scores, wall thickness on T1WI and T2WI, and ADC were all significantly correlated with degree of muscular hypertrophy. MRI predicts the degree of inflammation, and can distinguish prominent muscle hypertrophy from prominent fibrosis in ileal CD with reasonable accuracy (area under receiver operating characteristic curve [AUROC] > 0.7).

  7. Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test.

    PubMed

    Freitas, Raphael Ribeiro de Aquino; Tardelli, Maria Angela

    2016-05-24

    To compare sterility and microbial (bacteria and fungi) load in the outer part of hyperbaric bupivacaine (Neocaína®) in ampoule and bupivacaine in vial, in conventional and sterile pack formulations. The sterile packs were divided into two groups: G1 (n=16) with ampoules and G2 (n=16) with vials. Conventional formulations were divided into two groups, being G3 (n=16) with ampoules and G4 (n=16) with vials. The ampoules and vials were opened and had their content drawn. The empty bottles were then placed in sterile plastic bags and sent for analysis of microbial load (bacteria and fungi) and sterility testing. Data were analyzed using the χ2 test with Yates correction, and 95% confidence interval. G1 and G2 showed no bacterial growth when compared to conventional groups (p<0.001). The most common agent in conventional microbiological samples was Staphylococcus aureus. There was no fungal growth in both groups. The use of (sterile pack) reduces the microbial load of bottles, and would decrease the chance of exposure to potential contamination of the anesthetic solution. Comparar a esterilidade e a carga microbiana (bactérias e fungos) da parte externa dos frascos de envasamento de bupivacaína hiperbárica (Neocaína®) em ampola e bupivacaína em frasco-ampola das apresentações convencional e estéril (sterile pack). As apresentações estéreis (sterile pack) foram distribuídas em dois grupos, sendo que o G1 (n=16) continha as ampolas e o G2 (n=16), os frascos-ampola. As apresentações convencionais foram distribuídas em dois grupos, a saber G3 (n=16) com as ampolas e G4 (n=16) com os frascos-ampola. As ampolas e os frascos-ampolas eram abertos e tinham seu conteúdo aspirado. Os frascos vazios eram, então, acondicionados em sacos plásticos estéreis e enviados para análise quanto à carga microbiana (bactérias e fungos), bem como para o teste de esterilidade. Os dados foram analisados por meio do teste χ2 com correção Yates com intervalo de confiança de 95%. Os grupos G1 e G2 não apresentaram crescimento bacteriano quando comparado aos grupos convencionais (p<0,001). O microbiano mais comum nas amostras convencionais foi o Staphylococcus aureus. Não houve crescimento de fungos em nenhum dos grupos. O uso de embalagens estéreis (sterile pack) diminui a carga microbiana dos frascos de envasamentos, o que diminuiria a chance de exposição a uma potencial contaminação da solução anestésica.

  8. Optimized radiation-hardened erbium doped fiber amplifiers for long space missions

    NASA Astrophysics Data System (ADS)

    Ladaci, A.; Girard, S.; Mescia, L.; Robin, T.; Laurent, A.; Cadier, B.; Boutillier, M.; Ouerdane, Y.; Boukenter, A.

    2017-04-01

    In this work, we developed and exploited simulation tools to optimize the performances of rare earth doped fiber amplifiers (REDFAs) for space missions. To describe these systems, a state-of-the-art model based on the rate equations and the particle swarm optimization technique is developed in which we also consider the main radiation effect on REDFA: the radiation induced attenuation (RIA). After the validation of this tool set by confrontation between theoretical and experimental results, we investigate how the deleterious radiation effects on the amplifier performance can be mitigated following adequate strategies to conceive the REDFA architecture. The tool set was validated by comparing the calculated Erbium-doped fiber amplifier (EDFA) gain degradation under X-rays at ˜300 krad(SiO2) with the corresponding experimental results. Two versions of the same fibers were used in this work, a standard optical fiber and a radiation hardened fiber, obtained by loading the previous fiber with hydrogen gas. Based on these fibers, standard and radiation hardened EDFAs were manufactured and tested in different operating configurations, and the obtained data were compared with simulation data done considering the same EDFA structure and fiber properties. This comparison reveals a good agreement between simulated gain and experimental data (<10% as the maximum error for the highest doses). Compared to our previous results obtained on Er/Yb-amplifiers, these results reveal the importance of the photo-bleaching mechanism competing with the RIA that cannot be neglected for the modeling of the radiation-induced gain degradation of EDFAs. This implies to measure in representative conditions the RIA at the pump and signal wavelengths that are used as input parameters for the simulation. The validated numerical codes have then been used to evaluate the potential of some EDFA architecture evolutions in the amplifier performance during the space mission. Optimization of both the fiber length and the EDFA pumping scheme allows us to strongly reduce its radiation vulnerability in terms of gain. The presented approach is a complementary and effective tool for hardening by device techniques and opens new perspectives for the applications of REDFAs and lasers in harsh environments.

  9. The establishment of an attachment research network in Latin America: goals, accomplishments, and challenges.

    PubMed

    Causadias, José M; Sroufe, L Alan; Herreros, Francisca

    2011-03-01

    In the face of a pressing need for expanded attachment research programs and attachment informed interventions in Latin America, a research network was established: Red Iberoamericana de Apego: RIA (Iberian-American Attachment Network). The purpose of RIA is to promote human development and well being, informed by attachment theory, centering on research, and with implications for public policies, education, and intervention. We report the proceedings of the second meeting of RIA held in Panama City, Panama, in February 2010. As part of this meeting, RIA sponsored the first Latin-American attachment conference. Proceedings of the conference are described, as are future goals of this new organization.

  10. Assessment of Pharmacy Students' Communication Competence Using the Roter Interaction Analysis System During Objective Structured Clinical Examinations

    PubMed Central

    Kubota, Yoshie; Seki, Susumu; Takada, Kaori; Sakuma, Mio; Morimoto, Takeshi; Akaike, Akinori; Hiraide, Atsushi

    2011-01-01

    Objective To determine the value of using the Roter Interaction Analysis System during objective structured clinical examinations (OSCEs) to assess pharmacy students' communication competence. Methods As pharmacy students completed a clinical OSCE involving an interview with a simulated patient, 3 experts used a global rating scale to assess students' overall performance in the interview, and both the student's and patient's languages were coded using the Roter Interaction Analysis System (RIAS). The coders recorded the number of utterances (ie, units of spoken language) in each RIAS category. Correlations between the raters' scores and the number and types of utterances were examined. Results There was a significant correlation between students' global rating scores on the OSCE and the number of utterances in the RIAS socio-emotional category but not the RIAS business category. Conclusions The RIAS proved to be a useful tool for assessing the socio-emotional aspect of students' interview skills. PMID:21655397

  11. Measurement of steroids in rats after exposure to an endocrine disruptor: mass spectrometry and radioimmunoassay demonstrate similar results.

    PubMed

    Riffle, Brandy W; Henderson, W Matthew; Laws, Susan C

    2013-01-01

    Commercially available radioimmunoassays (RIAs) are frequently used to evaluate the effects of endocrine disrupting chemicals (EDCs) on steroidogenesis in rats. Currently there are limited data comparing steroid concentrations in rats as measured by RIAs to those obtained using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). This study evaluates the concordance of serum and urine steroid concentrations as quantified by select RIA kits and LC-MS/MS following exposure to an EDC, atrazine (ATR). Adult male rats were orally dosed with ATR (200 mg/kg/day) or methylcellulose (1%, vehicle control) for 5 days. Serum was collected and separated into aliquots for analysis. Serum was assayed by RIA for androstenedione (ANDRO), corticosterone (CORT), estradiol (E2), estrone (E1), progesterone (P4), and testosterone (T). Serum was extracted prior to LC-MS/MS analysis with positive electrospray ionization in multiple-reaction monitoring mode for ANDRO, CORT, P4, and T. E1 and E2 concentrations were quantified similarly by LC-MS/MS, following derivatization with dansyl chloride. To compare CORT values from urine, pregnant adult rats were orally dosed with either ATR (100 mg/kg/day) or methylcellulose for 5 days (i.e., gestational days 14-18). Urine samples were collected daily and assayed for CORT by RIA and LC-MS/MS as described above. Data analyses demonstrated significant agreement between the two detection methods as assessed by Pearson product-moment correlation coefficient, Bland-Altman analysis, and the interclass correlation coefficient. No statistically significant differences were observed between RIA and LC-MS/MS means for any of the steroids assayed. These findings indicate a significant correlation between the measurement of steroids within rat serum and urine using RIA kits and LC-MS/MS. Differences in the absolute measurements existed, but these were not statistically significant. These findings indicate that steroids may be reliably measured in rat biological media using RIAs or LC-MS/MS. © 2013.

  12. Anticoccidial efficacy testing: In vitro Eimeria tenella assays as replacement for animal experiments.

    PubMed

    Thabet, Ahmed; Zhang, Runhui; Alnassan, Alaa-Aldin; Daugschies, Arwid; Bangoura, Berit

    2017-01-15

    Availability of an accurate in vitro assay is a crucial demand to determine sensitivity of Eimeria spp. field strains toward anticoccidials routinely. In this study we tested in vitro models of Eimeria tenella using various polyether ionophores (monensin, salinomycin, maduramicin, and lasalocid) and toltrazuril. Minimum inhibitory concentrations (MIC 95 , MIC 50/95 ) for the tested anticoccidials were defined based on a susceptible reference (Houghton strain), Ref-1. In vitro sporozoite invasion inhibition assay (SIA) and reproduction inhibition assay (RIA) were applied on sensitive laboratory (Ref-1 and Ref-2) and field (FS-1, FS-2, and FS-3) strains to calculate percent of inhibition under exposure of these strains to the various anticoccidials (%I SIA and%I RIA, respectively). The in vitro data were related to oocyst excretion, lesion scores, performance, and global resistance indices (GI) assessed in experimentally infected chickens. Polyether ionophores applied in the RIA were highly effective at MIC 95 against Ref-1 and Ref-2 (%I RIA ≥95%). In contrast, all tested field strains displayed reduced to low efficacy (%I RIA <95%).%I RIA values significantly correlated with oocyst excretion determined in the animal model (p<0.01) for polyether ionophores. However, this relationship could not be demonstrated for toltrazuril due to unexpected lack of in vitro sensitivity in Ref-2 (%I RIA =56.1%). In infected chickens, toltrazuril was generally effective (GI>89%) against all strains used in this study. However, adjusted GI (GI adj ) for toltrazuril-treated groups exhibited differences between reference and field strains which might indicate varying sensitivity. RIA is a suitable in vitro tool to detect sensitivity of E. tenella towards polyether ionophores, and may thus help to reduce, replace, or refine use of animal experimentation for in vivo sensitivity assays. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Diagnostic accuracy of the anti-glutamic acid decarboxylase antibody in type 1 diabetes mellitus: Comparison between radioimmunoassay and enzyme-linked immunosorbent assay.

    PubMed

    Murata, Takashi; Tsuzaki, Kokoro; Nirengi, Shinsuke; Watanabe, Tomokazu; Mizutani, Yukako; Okada, Hayami; Tsukamoto, Masami; Odori, Shinji; Nakagawachi, Reiko; Kawaguchi, Yaeko; Yoshioka, Fumi; Yamada, Kazunori; Shimatsu, Akira; Kotani, Kazuhiko; Satoh-Asahara, Noriko; Sakane, Naoki

    2017-07-01

    The distributer of the anti-glutamic acid decarboxylase antibody assay kit using radioimmunoassay (RIA) recently announced its discontinuation, and proposed an alternative kit using enzyme-linked immunosorbent assay (ELISA). The aim of the present study was to investigate the diagnostic values of the anti-glutamic acid decarboxylase antibody by RIA and ELISA among type 1 diabetes mellitus patients and control participants. A total of 79 type 1 diabetes mellitus patients and 79 age-matched controls were enrolled and assessed using RIA and ELISA. Sensitivity, specificity, positive predictive values and negative predictive values were calculated for cut-off values (RIA = 1.5 U/mL and ELISA = 5.0 U/mL, respectively). Kappa coefficients were used to test for agreements between the RIA and ELISA methods regarding the diagnosis of type 1 diabetes mellitus. The sensitivity, specificity, positive predictive values, and negative predictive values for diagnosing type 1 diabetes mellitus were 57.0, 97.5, 95.7, and 69.4% by RIA, and 60.8, 100.0, 100.0 and 71.8% by ELISA, respectively. The diagnosis of type 1 diabetes mellitus using the RIA and ELISA methods showed substantial agreement with the kappa values of 0.74 for all participants, and of 0.64 for the acute type; however, there was moderate agreement with the kappa value of 0.56 for the slowly progressive type. The present study suggests that both anti-glutamic acid decarboxylase antibody by RIA and ELISA was useful for diagnosing type 1 diabetes mellitus. However, in the slowly progressive type, the degree of agreement of these two kits was poorer compared with those in all participants or in the acute type. © 2016 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.

  14. An interlaboratory study measuring sex steroids with RIAs and/or ELISAs: Are we comparing apples to oranges?

    EPA Science Inventory

    Endocrine-disrupting chemicals (EDCs) are exogenous substances released into the environment that can lead to adverse reproductive effects in fish by a number of mechanisms including altering circulating levels of estradiol (E2), testosterone (T) and 11-ketotestosterone (11KT). ...

  15. [The trajectory of a public service for alcohol and drug addicts in Vitória: the case of the CPTT].

    PubMed

    Dos Reis, Rossana; Garcia, Maria Lúcia Teixeira

    2008-01-01

    The aim of this case study is to analyze the Center for Prevention and Treatment of Alcohol and Drug Addiction (CPTT)/Psychosocial Care Center in Drugs and Alcohol (CAPS ad), and to reflect about the implementation process of the local addiction recovery policy for drug users and alcoholics. A document research was performed using as sources the CPTTs mid-year/annual and/or management reports and articles about the service. Data were analyzed using a priori and a posteriori content analysis. The CPTT, a health service of the government of the city of Vitória, was created in 1992 as a psychosocial service. The services provided by the CPTT include individual care, daily group activities and reception and follow-up groups. Today, the situation in the CPTT is characterized by precarious employment relations for most of the professionals working there. The trajectory of the implementation of the CPTT in the city of Vitória expresses two contradictory features: on one hand the advances made in the implementation of the public policy for prevention and treatment of drug and alcohol abuse, and on the other hand the challenge posed by the lack of a human resources policy capable of putting in effect the advances proposed by the policy.

  16. ANATOMIC VARIATIONS OF HEPATIC ARTERY: A STUDY IN 479 LIVER TRANSPLANTATIONS.

    PubMed

    Fonseca-Neto, Olival Cirilo Lucena da; Lima, Heloise Caroline de Souza; Rabelo, Priscylla; Melo, Paulo Sérgio Vieira de; Amorim, Américo Gusmão; Lacerda, Cláudio Moura

    2017-01-01

    The incidence of anatomic variations of hepatic artery ranges from 20-50% in different series. Variations are especially important in the context of liver orthotopic transplantation, since, besides being an ideal opportunity for surgical anatomical study, their precise identification is crucial to the success of the procedure. To identify the anatomical variations in the hepatic arterial system in hepatic transplantation. 479 medical records of transplanted adult patients in the 13-year period were retrospectively analyzed, and collected data on hepatic arterial anatomy of the deceased donor. It was identified normal hepatic arterial anatomy in 416 donors (86.84%). The other 63 patients (13.15%) showed some variation. According to the Michels classification, the most frequently observed abnormalities were: right hepatic artery branch of superior mesenteric artery (Type III, n=27, 5.63%); left hepatic artery branch of the left gastric artery (Type II, n=13, 2.71%); right hepatic artery arising from the superior mesenteric artery associated with the left hepatic artery arising from the left gastric artery (Type IV, n=4, 0.83%). Similarly, in relation to Hiatt classification, the most prevalent changes were: right hepatic accessory artery or substitute of the superior mesenteric artery (Type III, n=28, 6.05%)), followed by liver ancillary left artery or replacement of gastric artery left (Type II, n=16, 3.34. Fourteen donors (2.92%) showed no anatomical abnormalities defined in classifications, the highest frequency being hepatomesenteric trunk identified in five (01.04%). Detailed knowledge of the variations of hepatic arterial anatomy is of utmost importance to surgeons who perform approaches in this area, particularly in liver transplantation, since their identification and proper management are critical to the success of the procedure. A incidência das variações anatômicas da artéria hepática varia de 20-50% em diferentes casuísticas. Elas são especialmente importantes no contexto do transplante ortotópico hepático, visto que, além de representar oportunidade ideal para seu estudo anatômico cirúrgico, a sua precisa identificação é determinante para o sucesso do procedimento. Identificar as variações anatômicas no sistema arterial hepático em transplantes hepáticos. Foram analisados retrospectivamente, no período de 13 anos, 479 prontuários de pacientes adultos transplantados, sendo coletados dados referentes à anatomia arterial hepática do doador falecido. Identificou-se anatomia arterial hepática normal em 416 doadores (86,84%). Os outros 63 indivíduos (13,15%) apresentaram alguma variação. De acordo com a classificação de Michels, as anomalias mais frequentes foram: artéria hepática direita ramo da artéria mesentérica superior (Tipo III, n=27, 5,63%); artéria hepática esquerda ramo da artéria gástrica esquerda (Tipo II, n=13, 2,71%); artéria hepática direita ramo da artéria mesentérica superior associada à artéria hepática esquerda ramo da artéria gástrica esquerda (Tipo IV, n=4, 0,83%). Do mesmo modo, em relação à Classificação de Hiatt, as variações mais prevalentes foram: artéria hepática direita acessória ou substituta da artéria mesentérica superior (Tipo III, n=28, 6,05%), seguida da artéria hepática esquerda acessória ou substituta da artéria gástrica esquerda (Tipo II, n=16, 3,34%). Quatorze pessoas (2,92%) apresentaram alterações anatômicas sem classificação definida, sendo a de maior frequência o tronco hepatomesentérico, identificado em cinco (1,04%). O conhecimento detalhado das variações da anatomia arterial hepática é de grande importância aos cirurgiões que realizam abordagens nessa região, em especial no transplante hepático, visto que sua identificação e correto manejo são fundamentais para o êxito do procedimento.

  17. A comprehensive analysis of the thermodynamic events involved in ligand receptor binding using CoRIA and its variants

    NASA Astrophysics Data System (ADS)

    Verma, Jitender; Khedkar, Vijay M.; Prabhu, Arati S.; Khedkar, Santosh A.; Malde, Alpeshkumar K.; Coutinho, Evans C.

    2008-02-01

    Quantitative Structure-Activity Relationships (QSAR) are being used since decades for prediction of biological activity, lead optimization, classification, identification and explanation of the mechanisms of drug action, and prediction of novel structural leads in drug discovery. Though the technique has lived up to its expectations in many aspects, much work still needs to be done in relation to problems related to the rational design of peptides. Peptides are the drugs of choice in many situations, however, designing them rationally is a complicated task and the complexity increases with the length of their sequence. In order to deal with the problem of peptide optimization, one of our recently developed QSAR formalisms CoRIA (Comparative Residue Interaction Analysis) is being expanded and modified as: reverse-CoRIA ( rCoRIA) and mixed-CoRIA ( mCoRIA) approaches. In these methodologies, the peptide is fragmented into individual units and the interaction energies (van der Waals, Coulombic and hydrophobic) of each amino acid in the peptide with the receptor as a whole ( rCoRIA) and with individual active site residues in the receptor ( mCoRIA) are calculated, which along with other thermodynamic descriptors, are used as independent variables that are correlated to the biological activity by chemometric methods. As a test case, the three CoRIA methodologies have been validated on a dataset of diverse nonamer peptides that bind to the Class I major histocompatibility complex molecule HLA-A*0201, and for which some structure activity relationships have already been reported. The different models developed, and validated both internally as well as externally, were found to be robust with statistically significant values of r 2 (correlation coefficient) and r 2 pred (predictive r 2). These models were able to identify all the structure activity relationships known for this class of peptides, as well uncover some new relationships. This means that these methodologies will perform well for other peptide datasets too. The major advantage of these approaches is that they explicitly utilize the 3D structures of small molecules or peptides as well as their macromolecular targets, to extract position-specific information about important interactions between the ligand and receptor, which can assist the medicinal and computational chemists in designing new molecules, and biologists in studying the influence of mutations in the target receptor on ligand binding.

  18. Reliability associated with the Roter Interaction Analysis System (RIAS) adapted for the telemedicine context.

    PubMed

    Nelson, Eve-Lynn; Miller, Edward Alan; Larson, Kiley A

    2010-01-01

    This study's purpose was to adapt the Roter Interaction Analysis System (RIAS) for telemedicine clinics and to investigate the adapted measure's reliability. The study also sought to better understand the volume of technology-related utterance in established telemedicine clinics and the feasibility of using the measure within the telemedicine setting. This initial evaluation is a first step before broadly using the adapted measure across technologies and raters. An expert panel adapted the RIAS for the telemedicine context. This involved accounting for all consultation participants (patient, provider, presenter, family) and adding technology-specific subcategories. Ten new and 36 follow-up telemedicine encounters were videotaped and double coded using the adapted RIAS. These consisted primarily of follow-up visits (78.0%) involving patients, providers, presenters, and other parties. Reliability was calculated for those categories with 15 or more utterances. Traditional RIAS categories related to socioemotional and task-focused clusters had fair to excellent levels of reliability in the telemedicine setting. Although there were too few utterances to calculate the reliability of the specific technology-related subcategories, the summary technology-related category proved reliable for patients, providers, and presenters. Overall patterns seen in traditional patient-provider interactions were observed, with the number of provider utterances far exceeding patient, presenter, and family utterances, and few technology-specific utterances. The traditional RIAS is reliable when applied across multiple participants in the telemedicine context. Reliability of technology-related subcategories could not be evaluated; however, the aggregate technology-related cluster was found to be reliable and may be especially relevant in understanding communication patterns with patients new to the telemedicine setting. Use of the RIAS instrument is encouraged to facilitate comparison between traditional, face-to-face clinics and telemedicine; among diverse consultation mediums and technologies; and across different specialties. Future research is necessary to further investigate the reliability and validity of adding technology-related subcategories to the RIAS. The limited number of technology-related utterances, however, implies a certain degree of comfort with two-way interactive video consultation among study participants. Telemedicine continues to increase access to healthcare. The technology-related categories of the adapted RIAS were reliable when aggregated, thereby providing a tool to better understand how telemedicine affects provider-patient communication and outcomes.

  19. Clinical laboratory verification of thyroglobulin concentrations in the presence of autoantibodies to thyroglobulin: comparison of EIA, radioimmunoassay and LC MS/MS measurements in an Urban Hospital.

    PubMed

    Wheeler, Sarah E; Liu, Li; Blair, Harry C; Sivak, Richard; Longo, Nancy; Tischler, Jeffery; Mulvey, Kathryn; Palmer, Octavia M Peck

    2017-12-08

    Thyroglobulin (Tg) measurements assess recurrence in post-thyroidectomy thyroid cancer patients. Tg measurements by enzyme immunoassays (EIA) can be falsely elevated by interference from Tg autoantibodies (TgAb). Radioimmunoassay (RIA) is less susceptible to TgAb interference and has been the standard-of-care test for TgAb positive patients. Recently developed liquid chromatography tandem mass spectrometry (LC-MS/MS) methods may eliminate TgAb interference. We assessed the performance of Tg measurements by EIA, RIA and LC-MS/MS to evaluate TgAb interference differences. We measured TgAb and Tg in 50 plasma samples from 40 patients in whom Tg measurement was part of their routine follow-up and 10 healthy volunteers. Discrepancy between EIA and both LC-MS/MS and RIA was observed at low Tg concentrations (≤ 7.55 ng/mL) in TgAb positive specimens (LC-MS/MS = 1.9 * EIA - 0.03, r = 0.68). RIA and LC-MS/MS Tg measurements in TgAb positive specimens with low Tg concentrations had improved correlation but demonstrated bias (LC MS/MS = 0.6 * RIA - 1.4, r = 0.90). Disagreement between methods may be attributed to LC-MS/MS reported Tg concentrations as undetectable compared to RIA. It seems likely that most discrepant cases are falsely elevated in RIA due to TgAb interference, however, some cases appear below the detection limit of LC-MS/MS; implementation of LC-MS/MS by clinicians will require lower detection limits.

  20. Fcγ receptor I alpha chain (CD64) expression in macrophages is critical for the onset of meningitis by Escherichia coli K1.

    PubMed

    Mittal, Rahul; Sukumaran, Sunil K; Selvaraj, Suresh K; Wooster, David G; Babu, M Madan; Schreiber, Alan D; Verbeek, J Sjef; Prasadarao, Nemani V

    2010-11-18

    Neonatal meningitis due to Escherichia coli K1 is a serious illness with unchanged morbidity and mortality rates for the last few decades. The lack of a comprehensive understanding of the mechanisms involved in the development of meningitis contributes to this poor outcome. Here, we demonstrate that depletion of macrophages in newborn mice renders the animals resistant to E. coli K1 induced meningitis. The entry of E. coli K1 into macrophages requires the interaction of outer membrane protein A (OmpA) of E. coli K1 with the alpha chain of Fcγ receptor I (FcγRIa, CD64) for which IgG opsonization is not necessary. Overexpression of full-length but not C-terminal truncated FcγRIa in COS-1 cells permits E. coli K1 to enter the cells. Moreover, OmpA binding to FcγRIa prevents the recruitment of the γ-chain and induces a different pattern of tyrosine phosphorylation of macrophage proteins compared to IgG2a induced phosphorylation. Of note, FcγRIa(-/-) mice are resistant to E. coli infection due to accelerated clearance of bacteria from circulation, which in turn was the result of increased expression of CR3 on macrophages. Reintroduction of human FcγRIa in mouse FcγRIa(-/-) macrophages in vitro increased bacterial survival by suppressing the expression of CR3. Adoptive transfer of wild type macrophages into FcγRIa(-/-) mice restored susceptibility to E. coli infection. Together, these results show that the interaction of FcγRI alpha chain with OmpA plays a key role in the development of neonatal meningitis by E. coli K1.

  1. BACTERICIDAL COATINGS ON TEXTILES FOR REMEDIATION OF INTERMICROBE ACTIVITY (BaCTeRIA) SUMMARY REPORT

    DTIC Science & Technology

    2017-07-07

    Activity by Bacillus sp. P11” Food Bioprocess Technol. 4:822- 828. (2011) Levy, S.B and Marshal,l B.; “ Antibacterial resistance worldwide: causes...TEXTILES FOR REMEDIATION OF INTERMICROBE ACTIVITY (BaCTeRIA) SUMMARY REPORT by Tobyn A. Branck Courtney M. Cowell Jennifer M. Rego and...October 2011 – September 2015 4. TITLE AND SUBTITLE BACTERICIDAL COATINGS ON TEXTILES FOR REMEDIATION OF INTERMICROBE ACTIVITY (BaCTeRIA) SUMMARY REPORT

  2. The role of serum erythropoietin level and JAK2 V617F allele burden in the diagnosis of polycythaemia vera.

    PubMed

    Ancochea, Agueda; Alvarez-Larrán, Alberto; Morales-Indiano, Cristian; García-Pallarols, Francesc; Martínez-Avilés, Luz; Angona, Anna; Senín, Alicia; Bellosillo, Beatriz; Besses, Carles

    2014-11-01

    Low serum erythropoietin (EPO) is a minor criterion of Polycythaemia Vera (PV) but its diagnostic usefulness relies on studies performed before the discovery of JAK2 V617F mutation. The objective of the present study was to evaluate the diagnostic accuracy of serum EPO and JAK2 V617F allele burden as markers of PV as well as the combination of different diagnostic criteria in 287 patients (99 with PV, 137 with Essential Thrombocythaemia and 51 with non-clonal erythrocytosis). Low EPO showed good diagnostic accuracy as a marker for PV, with the area under the curve (AUC) of the chemiluminescent-enhanced enzyme immunoassay (CEIA) being better than that of radioimmunoassay (RIA) (0·87 and 0·76 for CEIA and RIA, respectively). JAK2 V617F quantification displayed an excellent diagnostic accuracy, with an AUC of 0·95. A haematocrit >52% (males) or >48% (females) plus the presence of the JAK2 V617F mutation had a sensitivity and specificity of 79% and 97%, respectively. Adding low EPO or the JAK2 V617F allele burden did not improve the diagnostic accuracy for PV whereas the inclusion of both improved the sensitivity up to 83% and maintaining 96% specificity. Haematocrit and qualitative JAK2 V617F mutation allow a reliable diagnosis of PV. Incorporation of EPO and/or JAK2 V617F mutant load does not improve the diagnostic accuracy. © 2014 John Wiley & Sons Ltd.

  3. Illustrated Plant Identification Keys: An Interactive Tool to Learn Botany

    ERIC Educational Resources Information Center

    Silva, Helena; Pinho, Rosa; Lopes, Lisia; Nogueira, Antonio J. A.; Silveira, Paulo

    2011-01-01

    An Interactive Dichotomous Key (IDK) for 390 "taxa" of vascular plants from the Ria de Aveiro, available on a website, was developed to help teach botany to school and universitary students. This multimedia tool includes several links to Descriptive and Illustrated Glossaries. Questionnaires answered by high-school and undergraduate students about…

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jensen, Colby B.; Folsom, Charles P.; Davis, Cliff B.

    Experimental testing in the Multi-Static Environment Rodlet Transient Test Apparatus (SERTTA) will lead the rebirth of transient fuel testing in the United States as part of the Accident Tolerant Fuels (ATF) progam. The Multi-SERTTA is comprised of four isolated pressurized environments capable of a wide variety of working fluids and thermal conditions. Ultimately, the TREAT reactor as well as the Multi-SERTTA test vehicle serve the purpose of providing desired thermal-hydraulic boundary conditions to the test specimen. The initial ATF testing in TREAT will focus on reactivity insertion accident (RIA) events using both gas and water environments including typical PWR operatingmore » pressures and temperatures. For the water test environment, a test configuration is envisioned using the expansion tank as part of the gas-filled expansion volume seen by the test to provide additional pressure relief. The heat transfer conditions during the high energy power pulses of RIA events remains a subject of large uncertainty and great importance for fuel performance predictions. To support transient experiments, the Multi-SERTTA vehicle has been modeled using RELAP5 with a baseline test specimen composed of UO2 fuel in zircaloy cladding. The modeling results show the influence of the designs of the specimen, vehicle, and transient power pulses. The primary purpose of this work is to provide input and boundary conditions to fuel performance code BISON. Therefore, studies of parameters having influence on specimen performance during RIA transients are presented including cladding oxidation, power pulse magnitude and width, cladding-to-coolant heat fluxes, fuel-to-cladding gap, transient boiling effects (modified CHF values), etc. The results show the great flexibility and capacity of the TREAT Multi-SERTTA test vehicle to provide testing under a wide range of prototypic thermal-hydraulic conditions as never done before.« less

  5. A comparison of low IQ scores from the Reynolds Intellectual Assessment Scales and the Wechsler Adult Intelligence Scale-Third Edition.

    PubMed

    Umphress, Thomas B

    2008-06-01

    Twenty people with suspected intellectual disability took the Reynolds Intellectual Assessment Scales (RIAS; C. R. Reynolds & R. W. Kamphaus, 1998) and the Wechsler Adult Intelligence Scale-3rd Edition (WAIS-III; D. Wechsler, 1997) to see if the 2 IQ tests produced comparable results. A t test showed that the RIAS Composite Intelligence Index scores were significantly higher than WAIS-III Full Scale IQ scores at the alpha level of .01. There was a significant difference between the RIAS Nonverbal Intelligence and WAIS-III Performance Scale, but there was no significant difference between the RIAS Verbal Intelligence Index and the WAIS-III Verbal Scale IQ. The results raise questions concerning test selection for diagnosing intellectual disability and the use of the correlation statistic for comparing intelligence tests.

  6. Dog cloning with in vivo matured oocytes obtained using electric chemiluminescence immunoassay-predicted ovulation method.

    PubMed

    Lee, Seunghoon; Zhao, Minghui; No, Jingu; Nam, Yoonseok; Im, Gi-Sun; Hur, Tai-Young

    2017-01-01

    Radioactive immunoassay (RIA) is a traditional serum hormone assay method, but the application of the method in reproductive studies is limited by the associated radioactivity. The aim of present study was to evaluate the reliability of RIA and to compare its canine serum progesterone concentration determination accuracy to that of the electric chemiluminescence immunoassay (ECLI). In vivo matured oocytes were utilized for canine somatic cell nuclear transfer (SCNT), and serum progesterone levels were assessed to accurately determine ovulation and oocyte maturation. Canine serum progesterone concentrations during both proestrus and estrus were analyzed by RIA and ECLI to determine the ovulation day. Although both methods detected similar progesterone levels before ovulation, the mean progesterone concentration determined using ECLI was significantly higher than of RIA three days before ovulation. Following ovulation, oocytes were collected by surgery, and a lower percentage of mature oocytes were observed using ECLI (39%) as compared to RIA (67%) if 4-8ng/ml of progesterone were used for determination of ovulation. A high percentage of mature oocytes was observed using ECLI when 6-15 ng/mL of progesterone was used for ovulation determination. To determine whether ECLI could be used for canine cloning, six canines were selected as oocyte donors, and two puppies were obtained after SCNT and embryo transfer. In conclusion, compared to the traditional RIA method, the ECLI method is a safe and reliable method for canine cloning.

  7. Dog cloning with in vivo matured oocytes obtained using electric chemiluminescence immunoassay-predicted ovulation method

    PubMed Central

    No, Jingu; Nam, Yoonseok; Im, Gi-Sun; Hur, Tai-Young

    2017-01-01

    Radioactive immunoassay (RIA) is a traditional serum hormone assay method, but the application of the method in reproductive studies is limited by the associated radioactivity. The aim of present study was to evaluate the reliability of RIA and to compare its canine serum progesterone concentration determination accuracy to that of the electric chemiluminescence immunoassay (ECLI). In vivo matured oocytes were utilized for canine somatic cell nuclear transfer (SCNT), and serum progesterone levels were assessed to accurately determine ovulation and oocyte maturation. Canine serum progesterone concentrations during both proestrus and estrus were analyzed by RIA and ECLI to determine the ovulation day. Although both methods detected similar progesterone levels before ovulation, the mean progesterone concentration determined using ECLI was significantly higher than of RIA three days before ovulation. Following ovulation, oocytes were collected by surgery, and a lower percentage of mature oocytes were observed using ECLI (39%) as compared to RIA (67%) if 4-8ng/ml of progesterone were used for determination of ovulation. A high percentage of mature oocytes was observed using ECLI when 6–15 ng/mL of progesterone was used for ovulation determination. To determine whether ECLI could be used for canine cloning, six canines were selected as oocyte donors, and two puppies were obtained after SCNT and embryo transfer. In conclusion, compared to the traditional RIA method, the ECLI method is a safe and reliable method for canine cloning. PMID:28288197

  8. From radioimmunoassay to mass spectrometry: a new method to quantify orexin-A (hypocretin-1) in cerebrospinal fluid

    PubMed Central

    Hirtz, Christophe; Vialaret, Jérôme; Gabelle, Audrey; Nowak, Nora; Dauvilliers, Yves; Lehmann, Sylvain

    2016-01-01

    I125 radioimmunoassay (RIA) is currently the standard technique for quantifying cerebrospinal fluid (CSF) orexin-A/hypocretin-1, a biomarker used to diagnose narcolepsy type 1. However, orexin-A RIA is liable to undergo cross-reactions with matrix constituents generating interference, high variability between batches, low precision and accuracy, and requires special radioactivity precautions. Here we developed the first quantitative mass spectrometry assay of orexin-A based on a multiple reaction monitoring (MRM) approach. This method was tested in keeping with the Clinical and Laboratory Standards Institute (CLSI) guidelines and its clinical relevance was confirmed by comparing patients with narcolepsy type 1 versus patients with other neurological conditions. The results obtained using MRM and RIA methods were highly correlated, and Bland–Altman analysis established their interchangeability. However, the MRM values had a wider distribution and were 2.5 time lower than the RIA findings. In conclusion, this method of assay provides a useful alternative to RIA to quantify orexin-A, and may well replace it not only in narcolepsy type 1, but also in the increasing number of pathologies in which the quantification of this analyte is relevant. PMID:27165941

  9. Computerized optimization of radioimmunoassays for hCG and estradiol: an experimental evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yanagishita, M.; Rodbard, D.

    1978-07-15

    The mathematical and statistical theory of radioimmunoassays (RIAs) has been used to develop a series of computer programs to optimize sensitivity or precision at any desired dose level for either equilibrium or nonequilibrium assays. These computer programs provide for the calculation of the equilibrium constants of association and binding capacities for antisera (parameters of Scatchard plots), the association and dissociation rate constants, and prediction of optimum concentration of labeled ligand and antibody and optimum incubation times for the assay. This paper presents an experimental evaluation of the use of these computer programs applied to RIAs for human chorionic gonadotropin (hCG)more » and estradiol. The experimental results are in reasonable semiquantitative agreement with the predictions of the computer simulations (usually within a factor of two) and thus partially validate the use of computer techniques to optimize RIAs that are reasonably well behaved, as in the case of the hCG and estradiol RIAs. Further, these programs can provide insights into the nature of the RIA system, e.g., the general nature of the sensitivity and precision surfaces. This facilitates empirical optimization of conditions.« less

  10. Validation of sparse sampling strategies to estimate cyclosporine A area under the concentration-time curve using either a specific radioimmunoassay or high-performance liquid chromatography method.

    PubMed

    Koristkova, Blanka; Grundmann, Milan; Brozmanova, Hana; Perinova, Ilona; Safarcik, Kristian

    2010-10-01

    Area under the concentration-time curve (AUC) has been advocated as a better parameter to monitor cyclosporine A than trough concentrations. Up to now, more than 100 equations to estimate AUC using a limited sampling strategy have been published, but not all have been validated. Eight equations for AUC0-12h and two for AUC0-8h were validated. Concentrations of cyclosporine A were analyzed by high-performance liquid chromatography (HPLC) and a specific radioimmunoassay (RIA) method. Forty male renal transplant patients were included in the study. Blood samples were taken predose and at 0.5, 1, 1.5, 2, 3, 5, 8, and 12 hours after the morning dose when the patient was in steady state. The percentage prediction error (%pe) was used for an assessment of the performance of the equations. Mean %pe less than ± 15% and absolute %pe less than 30% in 95% of predictions were considered to be acceptable. Other possibilities such as %pe less than 25%, 20%, and 15% were also tested. Eight equations for AUC0-12h met the requirements using both assays, six in the HPLC set only and four in the RIA set only. The highest precision was obtained with AUC0-12h = 123.792 + 1.165*C1h + 3.021*C3h + 7.33*C8h proposed by de Mattos et al. The mean %pe was 1% ± 8% (-16 to 19) for HPLC (values given as mean ± standard deviation [range]) and -1 ± 5 (-17 to 10) for RIA. Mean absolute %pe was 7 ± 5 (0.0 to 19) for HPLC and 4 ± 4 (0.0 to 17) for RIA. For clinical use, the most suitable equation was AUC0-12h = 363.078 + 8.77*C1h + 3.07*C3h proposed by Wacke et al, which produced the second lowest %pe and used two sampling points in the period of 1 to 3 hours after dose. The mean %pe was -7 ± 10 (-25 to 25) for HPLC and 2.3 ± 6 (-10 to 17) for RIA. Mean absolute %pe was 10 ± 7 (0.4 to 25) for HPLC and 5 ± 4 (0.0 to 17) for RIA. The equation: AUC0-8h = 55.37 + 2.89*C0h + 1.08*C1h0.9*C2h + 2.23*C3h proposed by Foradori et al met the criteria with 95% of prediction with absolute %pe less than 15% in the HPLC set and 10% in the RIA set. The validation of equations is of major importance for prediction precision, whereas the analytical method for limited sampling strategy proposals had no influence. Because of the wide interassay variability, it is also important to know which analytical method was used for AUC calculation when interpreting the results.

  11. Tsunami inundation after the Great East Japan Earthquake and mortality of affected communities.

    PubMed

    Ishiguro, A; Yano, E

    2015-10-01

    To examine the relationship between mortality rate and tsunami inundation after the Great East Japan Earthquake (GEJE) in 2011. Cross-sectional study. One hundred and fifty-five town or village sections in Ishinomaki, Myagi Prefecture, were included in this study. Three areas in the city were classified by characteristic landforms: plains area (n = 114), ria coastal area (n = 27) and Kitakami riverside (n = 14). The correlation coefficient between tsunami inundation depth and mortality rate was calculated for each area, and the differences between the areas were examined. Furthermore, multivariate analyses adjusted for the characteristics of the sections were conducted using census data taken before the GEJE. An association was found between inundation depth and mortality rate for Ishinomaki as a whole (r = 0.65, P < 0.001), Kitakami riverside (r = 0.85, P < 0.001) and the plains area (r = 0.75, P < 0.001) in separate analyses. However, no association was detected between inundation depth and mortality rate for the ria coastal area (r = 0.14, P = 0.47). The ria coastal area has good accessibility to the hills and tight bonding between members of the community. These factors seemed to play crucial roles in the lower mortality rate in this area despite the deep inundation. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Fish Biodiversity of the Vitória-Trindade Seamount Chain, Southwestern Atlantic: An Updated Database

    PubMed Central

    Pinheiro, Hudson T.; Mazzei, Eric; Moura, Rodrigo L.; Amado-Filho, Gilberto M.; Carvalho-Filho, Alfredo; Braga, Adriana C.; Costa, Paulo A. S.; Ferreira, Beatrice P.; Ferreira, Carlos Eduardo L.; Floeter, Sergio R.; Francini-Filho, Ronaldo B.; Gasparini, João Luiz; Macieira, Raphael M.; Martins, Agnaldo S.; Olavo, George; Pimentel, Caio R.; Rocha, Luiz A.; Sazima, Ivan; Simon, Thiony; Teixeira, João Batista; Xavier, Lucas B.; Joyeux, Jean-Christophe

    2015-01-01

    Despite a strong increase in research on seamounts and oceanic islands ecology and biogeography, many basic aspects of their biodiversity are still unknown. In the southwestern Atlantic, the Vitória-Trindade Seamount Chain (VTC) extends ca. 1,200 km offshore the Brazilian continental shelf, from the Vitória seamount to the oceanic islands of Trindade and Martin Vaz. For a long time, most of the biological information available regarded its islands. Our study presents and analyzes an extensive database on the VTC fish biodiversity, built on data compiled from literature and recent scientific expeditions that assessed both shallow to mesophotic environments. A total of 273 species were recorded, 211 of which occur on seamounts and 173 at the islands. New records for seamounts or islands include 191 reef fish species and 64 depth range extensions. The structure of fish assemblages was similar between islands and seamounts, not differing in species geographic distribution, trophic composition, or spawning strategies. Main differences were related to endemism, higher at the islands, and to the number of endangered species, higher at the seamounts. Since unregulated fishing activities are common in the region, and mining activities are expected to drastically increase in the near future (carbonates on seamount summits and metals on slopes), this unique biodiversity needs urgent attention and management. PMID:25738798

  13. Total Triiodothyronine by Fluorescence Polarization Immunoassay (FPIA),

    DTIC Science & Technology

    Graves ’ disease . Traditionally, radioimmunoassays (RIA) have been employed for the determination of total T3. Enzyme immunoassays (EIA) and fluorescence immunoassays (FIA) have been developed for many of the analytes that formerly were measured using RIA. One variation of this new generation of immunoassays is fluorescence polarization. A fluorescence polarization immunoassay (FPIA) method for total T3 has been automated by adaptation to the TDx (Abbott, Chicago, IL) clinical analyzer. The TDx total T3 assay has been evaluated as a replacement for an RIA total T3

  14. Does microphytobenthos resuspension influence phytoplankton in shallow systems? A comparison through a Fourier series analysis

    NASA Astrophysics Data System (ADS)

    Brito, Ana C.; Fernandes, Teresa F.; Newton, Alice; Facca, Chiara; Tett, Paul

    2012-09-01

    Shallow coastal lagoons, especially the ones with clear waters and lighted substrata, are likely to have large microphytobenthos (MPB) communities. MPB is an important component of these systems, representing up to 99% of the chlorophyll concentration when compared to phytoplankton. It is therefore expected that MPB resuspension play a key role in the dynamics of phytoplankton due to the tide and wind action. Water samples were collected twice per month inside and outside Ria Formosa lagoon (Portugal), for nutrients and chlorophyll a (chl a). Sediment samples were also collected for MPB chl a. Chl a was also analysed in water and sediment samples from Venice lagoon (Italy), at least once per month. A truncated Fourier series was fitted to the data to investigate the seasonal and high-frequency components of the time-series. In the Ria Formosa, the best significant fit for MPB was obtained considering the sum of 26 wave-pairs (sin and cosine), which explained 31% of the variability. The seasonal cycle (1-3 waves) explained approximately 5% of the total variability. Within-day variability which includes spatial heterogeneity explained 61% of the variability. The best fit for phytoplankton inside Ria Formosa was obtained considering the sum of 23 wave-pairs. Outside the lagoon the best fit was obtained using only the sum of 16 wave-pairs. For both cases, the sum of waves explained more than 64% of the variability and the seasonal cycle explained more than 31% of the variability. It is expected that primary producers in the water column have a strong seasonal factor due to the direct effect of the solar cycle, which is the case of other clear waters. In the Venice lagoon, which is microtidal, the best fit for MPB was obtained using 10 wave-pairs. However, the best fit for phytoplankton was obtained with only 3 wave-pairs, indicating the importance of the seasonal cycle. Significant relationships were found between phytoplankton inside and outside the Ria Formosa, as well as between microphytobenthos and phytoplankton in the lagoons of Venice and Ria Formosa. These results suggest the influence of MPB resuspension in the phytoplankton community of shallow coastal lagoons and the importance of phytoplankton exportation to the coastal zone.

  15. Thyroglobulin (Tg) Testing Revisited: Tg Assays, TgAb Assays, and Correlation of Results With Clinical Outcomes.

    PubMed

    Netzel, Brian C; Grebe, Stefan K G; Carranza Leon, B Gisella; Castro, M Regina; Clark, Penelope M; Hoofnagle, Andrew N; Spencer, Carole A; Turcu, Adina F; Algeciras-Schimnich, Alicia

    2015-08-01

    Measurement of thyroglobulin (Tg) by mass spectrometry (Tg-MS) is emerging as a tool for accurate Tg quantification in patients with anti-Tg autoantibodies (TgAbs). The objective of the study was to perform analytical and clinical evaluations of two Tg-MS assays in comparison with immunometric Tg assays (Tg-IAs) and Tg RIAs (Tg-RIAs) in a cohort of thyroid cancer patients. A total of 589 samples from 495 patients, 243 TgAb-/252 TgAb+, were tested by Beckman, Roche, Siemens-Immulite, and Thermo-Brahms Tg and TgAb assays, two Tg-RIAs, and two Tg-MS assays. The frequency of TgAb+ was 58%, 41%, 27%, and 39% for Roche, Beckman, Siemens-Immulite, and Thermo-Brahms, respectively. In TgAb- samples, clinical sensitivities and specificities of 100% and 74%-100%, respectively, were observed across all assays. In TgAb+ samples, all Tg-IAs demonstrated assay-dependent Tg underestimation, ranging from 41% to 86%. In TgAb+ samples, the use of a common cutoff (0.5 ng/mL) for the Tg-MS, three Tg-IAs, and the USC-RIA improved the sensitivity for the Tg-MSs and Tg-RIAs when compared with the Tg-IAs. In up to 20% of TgAb+ cases, Tg-IAs failed to detect Tg that was detectable by Tg-MS. In Tg-RIAs false-high biases were observed in TgAb+ samples containing low Tg concentrations. Tg-IAs remain the method of choice for Tg quantitation in TgAb- patients. In TgAb+ patients with undetectable Tg by immunometric assay, the Tg-MS will detect Tg in up to 20% additional cases. The Tg-RIA will detect Tg in approximately 35% cases, but a significant proportion of these will be clinical false-positive results. The undetectable Tg-MS seen in approximately 40% of TgAb+ cases in patients with disease need further evaluation.

  16. Remote infrared audible signage (RIAS) pilot program report.

    DOT National Transportation Integrated Search

    2011-07-01

    The Remote Infrared Audible Sign Model Accessibility Program (RIAS MAP) is a program funded by the Federal Transit Administration (FTA) to evaluate the effectiveness of remote infrared audible sign systems in enabling persons with visual and cognitiv...

  17. Correlation and comparison of Nb/sub 2/ lymphoma cell bioassay with radioimmunoassay for human prolactin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Subramanian, M.G.; Spirtos, N.J.; Moghissi, K.S.

    Serum samples from groups of men and women with normal and elevated prolactin (PRL) levels were assayed by radioimmunoassay (RIA) and by Nb/sub 2/ lymphoma cell bioassay (BA) for the presence of PRL. Because the Nb/sub 2/ lymphoma cells respond to both PRL and growth hormone, BA for PRL activity was carried out before and after neutralization of growth hormone in the serum samples. There were excellent correlations between RIA and BA both in euprolactinemic and hyperprolactinemic subjects. On an absolute basis, RIA and BA values were similar in the euprolactinemic group (6.6 +/- 0.8 versus 6.2 +/- 1.0), whereasmore » in the hyperprolactinemic group, RIA values were significantly higher than the BA results. The two assay systems also appeared to correlate better in women who were hyperprolactinemic, with obvious menstrual cycle disturbances, than in hyperprolactinemic women without menstrual cycle disturbances.« less

  18. A modeling study on the hydrodynamics of a coastal embayment occupied by mussel farms (Ria de Ares-Betanzos, NW Iberian Peninsula)

    NASA Astrophysics Data System (ADS)

    Duarte, Pedro; Alvarez-Salgado, Xosé Antón; Fernández-Reiriz, Maria José; Piedracoba, Silvia; Labarta, Uxío

    2014-06-01

    The present study suggests that both under upwelling and downwelling winds, the residual circulation of Ria de Ares-Betanzos remains positive with a strong influence from river discharge and a positive feedback from wind, unlike what is generally accepted for Galician rias. Furthermore, mussel cultivation areas may reduce residual velocities by almost 40%, suggesting their potential feedbacks on food replenishment for cultivated mussels. The Ria de Ares-Betanzos is a partially stratified estuary in the NW Iberian upwelling system where blue mussels are extensively cultured on hanging ropes. This type of culture depends to a large extent on water circulation and residence times, since mussels feed on suspended particles. Therefore, understanding the role of tides, continental runoff, and winds on the circulation of this embayment has important practical applications. Furthermore, previous works have emphasized the potential importance of aquaculture leases on water circulation within coastal ecosystems, with potential negative feedbacks on production carrying capacity. Here we implemented and validated a 3D hydrodynamic numerical model for the Ria de Ares-Betanzos to (i) evaluate the relative importance of the forcing agents on the circulation within the ria and (ii) estimate the importance of culture leases on circulation patterns at the scale of the mussel farms from model simulations. The model was successfully validated with empirical current velocity data collected during July and October 2007 using an assortment of efficiency criteria. Model simulations were carried out to isolate the effects of wind and river flows on circulation patterns.

  19. 24 CFR 3280.302 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Body and Frame Construction Requirements.... Loads: (1) Dead load: means the weight of all permanent construction including walls, floors, roof... occupancy of the manufactured home, including wind load and snow load, but not including dead load. (3) Wind...

  20. 24 CFR 3280.302 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Body and Frame Construction Requirements.... Loads: (1) Dead load: means the weight of all permanent construction including walls, floors, roof... occupancy of the manufactured home, including wind load and snow load, but not including dead load. (3) Wind...

  1. 24 CFR 3280.302 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Body and Frame Construction Requirements.... Loads: (1) Dead load: means the weight of all permanent construction including walls, floors, roof... occupancy of the manufactured home, including wind load and snow load, but not including dead load. (3) Wind...

  2. 24 CFR 3280.302 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Body and Frame Construction Requirements.... Loads: (1) Dead load: means the weight of all permanent construction including walls, floors, roof... occupancy of the manufactured home, including wind load and snow load, but not including dead load. (3) Wind...

  3. Comparison of a commercial bovine pregnancy-associated glycoprotein ELISA test and a pregnancy-associated glycoprotein radiomimmunoassay test for early pregnancy diagnosis in dairy cattle.

    PubMed

    Karen, Aly; Sousa, Noelita Melo De; Beckers, Jean-François; Bajcsy, Árpád Csaba; Tibold, János; Mádl, István; Szenci, Ottó

    2015-08-01

    The present study aimed to compare the accuracy of a commercial PAG-ELISA test (Bovine Preg Test 29) and bovine pregnancy-associated glycoprotein radioimmunoassay (PAG-RIA) for diagnosing pregnancy at Day 28 after insemination in dairy cows. Transrectal ultrasonography (TRUS) was performed in 100 Holstein-Friesian cows at Day 28 after artificial insemination (AI; Day 0) to diagnose pregnancy. After TRUS examination, blood sample was collected from the coccygeal vessels of each cow to measure the concentrations of bPAGs by PAG-RIA test and Bovine Preg Test 29. Milk samples were collected at Days 0, 21 and 28 for measurement of progesterone (P4) by ELISA test. The cows were re-examined by TRUS at Day 42 to confirm the pregnancy diagnoses. The actual gold standard was based on TRUS outcomes at Day 28 that agreed with the outcomes of PAG-RIA test or PAG-ELISA test. If the outcomes of TRUS at Day 28 and PAG-RIA test and PAG-ELISA test did not agree, the gold standard was based on the outcome of TRUS at Day 42. Out of 100 inseminated cows, 41 were confirmed pregnant at Day 28 after AI. Based on the actual gold standard, the sensitivity of TRUS, PAG-ELISA and PAG-RIA tests for diagnosing pregnant cows at Day 28 were 92.7%, 90.2% and 100%, while the specificity of the three tests for diagnosing non-pregnant cows were 91.5%, 98.3% and 94.4%, respectively. The overall accuracy of the three tests were 92%, 95% and 97%, respectively. The degree of agreement (Kappa±S.E.) between PAG-RIA and PAG-ELISA test was 0.90 ±0.04. The degrees of agreement between PAG-RIA and PAG-ELISA and TRUS at Day 28 were 0.80±0.05 and 0.76±0.06, respectively. In conclusion, the commercial PAG-ELISA test is a highly accurate method for diagnosing early pregnancy in dairy cows on Day 28 after AI and may be used as an alternative method to the TRUS and the PAG-RIA test. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Código para imageamento indireto de estrelas em sistemas binarios: simulação de variações elipsoidais e do perfil das linhas

    NASA Astrophysics Data System (ADS)

    Souza, T. R.; Baptista, R.

    2003-08-01

    As estrelas secundárias em variáveis cataclí smicas (VCs) e binárias-x de baixa massa (BXBMs) são cruciais para o entendimento da origem, evolução e comportamento destas binárias interagentes. Elas são estrelas magneticamente ativas submetidas a condições ambientais extremas [e.g., estão muito próximas de uma fonte quente e irradiante; têm rotação extremamente rápida e forma distorcida; estão perdendo massa a taxas de 10-8-10-10 M¤/ano] que contribuem para que suas propriedades sejam distintas das de estrelas de mesma massa na seqüência principal. Por outro lado, o padrão de irradiação na face da secundária fornece informação sobre a geometria das estruturas de acréscimo em torno da estrela primária. Assim, a obtenção de imagens da superfície destas estrelas é de grande interesse astrofísico. A Tomografia Roche usa as variações no perfil das linhas de emissão/absorção da estrela secundária em função da fase orbital para mapear a distribuição de brilho em sua superfície. Neste trabalho apresentamos os resultados iniciais do desenvolvimento de um programa para o mapeamento da distribuição de brilho na superfí cie das estrelas secundárias em VCs e BXBMs com técnicas de astro-tomografia. Presentemente temos em operação um código que simula as variações no perfil das linhas em conseqüência de efeito Doppler resultante da combinação de rotação e translação de uma estrela em forma de lobo de Roche em torno do centro de massa da binária, em função da distribuição de brilho na superfície desta estrela. O código igualmente produz a curva de luz resultante das variações de aspecto da estrela em função da fase orbital (variações elipsoidais).

  5. Health Conditions and Memory Performance: a study with older adult women.

    PubMed

    Nespollo, Alice Milani; Marcon, Samira Reschetti; Lima, Nathalie Vilma Pollo de; Dias, Tatiane Lebre; Espinosa, Mariano Martínez

    2017-01-01

    to verify the correlation between health condition and memory performance of older adult women in the community. Analytical cross-sectional study developed with 28 older adult women living in Cuiabá-MT. They answered the Mini-Mental State Examination (MMSE), and a shortened Geriatric Depression Scale (GDS-15) to screen for dementia and depression symptoms. Memory skills were assessed through Rey Auditory Verbal Learning Test (RAVLT). The mean age was 66.36 years and 75% of the participants had educational level higher than 7 years. The MMSE mean score was 28.45. The correlations found were: educational level and immediate memory (r = 0.49; p = 0.008); delayed recall and immediate memory (r = 0.71; p < 0.001); memory recognition and immediate memory (r = 0.43; p = 0.021) and recognition memory with delayed recall (r = 0.47; p = 0.012). High scores in the MMSE and a satisfactory health perception among the participants were evident. There was no correlation between memory performance and health perception. Verificar a correlação entre condições de saúde e desempenho da memória de idosas da comunidade. Estudo transversal analítico, realizado com 28 idosas residentes em Cuiabá-MT. Essas foram submetidas a rastreio para demências e sintomas depressivos por meio do Miniexame do Estado Mental (MEEM) e Escala de Depressão Geriátrica Abreviada (GDS-15). A avaliação das habilidades de memória ocorreu por meio do Teste de Aprendizagem Auditivo-Verbal de Rey (RAVLT). A idade média foi de 66,36 anos e 75% possuíam escolaridade maior que sete anos. A média do MEEM foi 28,45. As correlações encontradas foram: escolaridade e memória imediata (r = 0,49; p = 0,008); evocação tardia e memória de reconhecimento com memória imediata (r = 0,71; p < 0,001 e r = 0,43; p = 0,021) e memória de reconhecimento com evocação tardia (r = 0,47; p = 0,012). Evidenciou-se escore elevado no MEEM e percepção de saúde satisfatória entre os participantes. Não houve correlação entre desempenho da memória e percepção de saúde.

  6. Uma grade de perfis teóricos para estrelas massivas em transição

    NASA Astrophysics Data System (ADS)

    Nascimento, C. M. P.; Machado, M. A.

    2003-08-01

    Na XXVIII Reunião Anual da Sociedade Astronômica Brasileira (2002) apresentamos uma grade de perfis calculados de acordo com os pontos da trajetória evolutiva de metalicidade solar, Z = 0.02 e taxa de perda de massa () padrão, para estrelas com massa inicial de 25, 40, 60, 85 e 120 massas solares. Estes perfis foram calculados com o auxílio de um código numérico adequado para descrever os ventos de objetos massivos, supondo simetria esférica, estacionaridade e homogeneidade. No presente trabalho, apresentamos a complementação da grade com os perfis teóricos relativos às trajetórias de Z = 0.02 com taxa de perda de massa dobrada em relação a padrão (2´), e de metalicidade Z = 0.008. Para cada ponto das três trajetórias obtemos os perfis teóricos de Ha, Hb, Hg e Hd, e como esperado eles se apresentam em pura emissão, pura absorção ou em P-Cygni. Para valores de taxa de perda de massa muito baixos (~10-7) não há formação de linhas, o que é visto nos primeiros pontos em todas as trajetórias. Em geral, para um mesmo ponto a componente de emissão diminui e a absorção aumenta de Ha para Hd. É verificado que as trajetórias com Z = 0.02 e padrão possuem menos circuitos (loops) do que as com metalicidade Z = 0.02 e 2´ padrão, e seus perfis são, em geral, menos intensos. Em relação a trajetória de Z = 0.008, verifica-se menos circuitos e maior variação em luminosidade, e seus perfis mostram-se em, algumas trajetórias, mais intensos. Verificamos também que, pontos distintos em uma mesma trajetória, apresentam perfis diferentes para valores similares de luminosidade e temperatura efetiva. Sendo assim, uma grade de perfis teóricos parece ser útil para fornecer uma informação preliminar sobre o estágio evolutivo de uma estrela massiva.

  7. Identification of the soluble form of tyrosine kinase receptor Axl as a potential biomarker for intracranial aneurysm rupture.

    PubMed

    Xu, Jing; Ma, Feiqiang; Yan, Wei; Qiao, Sen; Xu, Shengquan; Li, Yi; Luo, Jianhong; Zhang, Jianmin; Jin, Jinghua

    2015-03-05

    Subarachnoid hemorrhage caused by a ruptured intracranial aneurysm (RIA) is a devastating condition with significant morbidity and mortality. Despite the fact that RIAs can be prevented by microsurgical clipping or endovascular coiling, there are no reliable means of effectively predicting IA patients at risk for rupture. The purpose of our study was to discover differentially-expressed glycoproteins in IAs with or without rupture as potential biomarkers to predict rupture. Forty age/gender-matched patients with RIA, unruptured IA (UIA), healthy controls (HCs) and disease controls (DCs) (discovery cohort, n = 10 per group) were recruited and a multiplex quantitative proteomic method, iTRAQ (isobaric Tagging for Relative and Absolute protein Quantification), was used to quantify relative changes in the lectin-purified glycoproteins in CSF from RIAs and UIAs compared to HCs and DCs. Then we verified the proteomic results in an independent set of samples (validation cohort, n = 20 per group) by enzyme-linked immunosorbent assay. Finally, we evaluated the specificity and sensitivity of the candidate marker with receiver operating characteristic (ROC) curve methods. The proteomic findings identified 294 proteins, 40 of which displayed quantitative changes unique to RIA, 13 to UIA, and 20 to IA. One of these proteins, receptor tyrosine kinase Axl, was significantly increased in RIA, as confirmed in CSF from the discovery cohort as well as in CSF and plasma from the validation cohort (p <0.05). Spearman's correlation analysis revealed that the CSF and plasma Axl levels were strongly correlated (r = 0.93, p <0.0001). The ROC curve indicated an optimal CSF Axl threshold of 0.12 nM for discriminating RIA from UIA with corresponding sensitivity/specificity of 73.33%/90% and an area under the curve (AUC) of 0.89 (95% CI: 0.80-0.97, p < 0.0001). The optimal threshold for plasma Axl was 1.7 nM with corresponding sensitivity/specificity of 50%/80% and an AUC of 0.71 (95% CI: 0.54-0.87, p = 0.027). Both CSF and plasma Axl levels are significantly elevated in RIA patients. Axl might serve as a promising biomarker to predict the rupture of IA.

  8. A Method to Determine the Impact of Patient-Centered Care Interventions in Primary Care

    PubMed Central

    Daaleman, Timothy P.; Shea, Christopher M.; Halladay, Jacqueline; Reed, David

    2014-01-01

    INTRODUCTION The implementation of patient-centered care (PCC) innovations continues to be poorly understood. We used the implementation effectiveness framework to pilot a method for measuring the impact of a PCC innovation in primary care practices. METHODS We analyzed data from a prior study that assessed the implementation of an electronic geriatric quality-of-life (QOL) module in 3 primary care practices in central North Carolina in 2011–12. Patients responded to the items and the subsequent patient-provider encounter was coded using the Roter Interaction Analysis System (RIAS) system. We developed an implementation effectiveness measure specific to the QOL module (i.e., frequency of usage during the encounter) using RIAS and then tested if there were differences with RIAS codes using analysis of variance. RESULTS A total of 60 patient-provider encounters examined differences in the uptake of the QOL module (i.e., implementation-effectiveness measure) with the frequency of RIAS codes during the encounter (i.e., patient-centeredness measure). There was a significant association between the effectiveness measure and patient-centered RIAS codes. CONCLUSION The concept of implementation effectiveness provided a useful framework determine the impact of a PCC innovation. PRACTICE IMPLICATIONS A method that captures real-time interactions between patients and care staff over time can meaningfully evaluate PCC innovations. PMID:25269410

  9. Regulatory Impact Analysis (RIA) for the Proposed Revisions to the Sulfur Dioxide National Ambient Air Quality Standards (NAAQS)

    EPA Pesticide Factsheets

    This Regulatory Impact Analysis (RIA) provides estimates of the incremental costs and monetized human health benefits of attaining a revised short‐term Sulfur Dioxide (SO2) NAAQS within the current monitoring network.

  10. Final Regulatory Impact Analysis (RIA) for the NO2 National Ambient Air Quality Standards (NAAQS)

    EPA Pesticide Factsheets

    This RIA provides illustrative estimates, as of January 2010, of the incremental costs and monetized human health benefits of attaining the revised NO2 NAAQS within the the existing community-wide monitoring network of 409 monitors.

  11. Pregnancy-associated glycoprotein (PAG) concentration in plasma and milk samples for early pregnancy diagnosis in Lacaune dairy sheep.

    PubMed

    El Amiri, B; Sousa, N M; Alvarez Oxiley, A; Hadarbach, D; Beckers, J F

    2015-04-01

    In the present study, four RIA systems (RIA-1 to -4) based on two antisera raised against ovine pregnancy-associated glycoproteins (ovPAGs), combined with an ovine or a bovine PAG tracer were used to measure PAG concentrations in plasma and milk samples of dairy ewes. Blood and milk samples were collected on different days of gestation: 0, 18, 20, 22, 25, 28, 32, 42, and 49. From day 20 onward, the PAG in plasma could be detected in all pregnant ewes using the four RIA systems. By using milk, except for RIA-1, the other systems showed a sensitivity of 100% from day 28 of gestation onward. In plasma, PAG concentrations were higher in multiple than in single pregnancies, while no clear relationship was observed in milk. In conclusion, milk is a good alternative to plasma for early pregnancy diagnosis in sheep from day 28 to day 42. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Doctors in a Southeast Asian country communicate sub-optimally regardless of patients' educational background.

    PubMed

    Claramita, Mora; Dalen, Jan Van; Van Der Vleuten, Cees Pm

    2011-12-01

    To explore the relationship between the style of doctor-patient communication and patients' educational background in a Southeast Asian teaching hospital setting using the Roter Interaction Analysis System (RIAS). We analyzed a total of 245 audio-taped consultations involving 30 internal medicine residents with 7-10 patients each in the internal medicine outpatient clinics. The patients were categorized into a group with a high and a group with a low educational level. We ranked the data into 41 RIAS utterances and RIAS-based composite categories in order of observed frequency during consultations. The residents invariantly used a paternalistic style irrespective of patients' educational background. The RIAS utterances and the composite categories show no significant relationship between communication style and patients' educational level. Doctors in a Southeast Asian country use a paternalistic communication style during consultations, regardless of patients' educational background. To approach a more partnership doctor-patient communication, culture and clinical environment concern of Southeast Asian should be further investigated. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. Latex agglutination inhibition card test for gentamicin assay: clinical evaluation and comparison with radioimmunoassay and bioassay.

    PubMed Central

    Standiford, H C; Bernstein, D; Nipper, H C; Caplan, E; Tatem, B; Hall, J S; Reynolds, J

    1981-01-01

    Gentamicin levels were determined in 100 serum specimens by a new latex agglutination inhibition card test, a radioimmunoassay (RIA), and a bioassay. Correlation coefficients determined by linear regression analysis demonstrated that the levels obtained by the latex agglutination inhibition card test had a high degree of correlation with the RIA and could be performed much faster and more economically when processing small numbers of specimens. The bioassay had a slightly lower degree of correlation with both the RIA and the latex test and was adversely influenced by concurrently administered antibiotics which could not be eliminated by beta-lactamase. When measuring gentamicin concentrations above 2 micrograms/ml, the coefficient of variation was less than 14% for the latex agglutination assay compared with 15% for the bioassay and 12% for RIA. The latex agglutination inhibition card test is a rapid, accurate, specific, and reproducible method for monitoring gentamicin levels in patients and is particularly applicable for laboratories processing small numbers of specimens. PMID:7247384

  14. Basin-scale contributions of Cr, Ni and Co from Ortegal Complex to the surrounding coastal environment (SW Europe).

    PubMed

    Prego, Ricardo; Caetano, Miguel; Ospina-Alvarez, Natalia; Raimundo, Joana; Vale, Carlos

    2014-01-15

    The enrichment of Cr and Ni in the coastal zones is usually associated with anthropogenic sources such as the tanning, galvanization, ceramic, and cement industries. However, geological complexes of specific lithologic composition located near shorelines may act as natural sources of metals to the continental shelf. Cape Ortegal (SW Europe) is an ultramafic complex that has Cr, Ni and Co enriched in rocks due to the minerals chromite, chromospinel, gersdorfite and pentlandite. Thus, the hypothesis that this geological complex contributes to metal enrichment in Ortigueira and Barqueiro Rias and the adjacent continental shelf was tested. Chromium, Ni, and Co were determined in water and in suspended particulate matter of ria tributaries, rainfall, surface sediments, mussels, and algae. High contents of Cr (max. 1670mg·kg(-1)) and Ni (max. 1360 mg · kg(-1)) were found in the sediments surrounding Cape Ortegal and the Ortigueira Ria as a result of erosion of exposed cliffs. Dissolved Cr and Ni concentrations in fluvial waters were significantly higher in the rivers that crosses the Ortegal Complex, i.e. Lourido (0.47 μg Cr · L(-1); 9.4 μg Ni · L(-1)) and Landoi (0.37 μg Cr · L(-1); 4.3 μg Ni · L(-1)), in comparison with the nearby basin out of the complex influence (Sor River: <0.01 μg Cr · L(-1); 0.57 μg Ni · L(-1)). The annual fluvial contributions of Cr and Ni to the Ortigueira Ria were higher than fluxes into the Barqueiro Ria. Moreover, the increase in Cr and Ni in the rainfall in summer demonstrated the importance of the atmosphere pathway for introducing these elements into the aquatic environment. As a consequence, the contents of these metals in soft tissues and shell of mussels and algae from the Ortigueira Ria were higher than the organisms from Barqueiro Ria. Thus, geological complexes, such as the Cape Ortegal, located in an uncontaminated area, can increase the land-sea exchange of trace metals. © 2013.

  15. Enhancement of the intrinsic defecation reflex by mosapride, a 5-HT4 agonist, in chronically lumbosacral denervated guinea pigs.

    PubMed

    Kojima, Yu; Fujii, Hisao; Katsui, Renta; Nakajima, Yoshiyuki; Takaki, Miyako

    2006-10-01

    The defecation reflex is composed of rectal distension-evoked rectal (R-R) reflex contractions and synchronous internal anal sphincter (R-IAS) reflex relaxations in guinea pigs. These R-R and R-IAS reflexes are controlled via extrinsic sacral excitatory nerve pathway (pelvic nerves), lumbar inhibitory nerve pathways (colonic nerves) and by intrinsic cholinergic excitatory and nitrergic inhibitory nerve pathways. The effect of mosapride (a prokinetic benzamide) on the intrinsic reflexes, mediated via enteric 5-HT(4) receptors, was evaluated by measuring the mechanical activity of the rectum and IAS in anesthetized guinea pigs using an intrinsic R-R and R-IAS reflex model resulting from chronic (two to nine days) lumbosacral denervation (PITH). In this model, the myenteric plexus remains undamaged and the distribution of myenteric and intramuscular interstitial cells of Cajal is unchanged. Although R-R and R-IAS reflex patterns markedly changed, the reflex indices (reflex pressure or force curve-time integral) of both the R-R contractions and the synchronous R-IAS relaxations were unchanged. The frequency of the spontaneous R and IAS motility was also unchanged. Mosapride (0.1-1.0 mg/kg) dose-dependently increased both intrinsic R-R (maximum: 1.82) and R-IAS reflex indices (maximum: 2.76) from that of the control (1.0) 6-9 days following chronic PITH. The dose-response curve was similar to that in the intact guinea pig, and had shifted to the left from that in the guinea pig after acute PITH. A specific 5-HT(4) receptor antagonist, GR 113808 (1.0 mg/kg), decreased both reflex indices by approximately 50% and antagonized the effect of mosapride 1.0 mg/kg. This was quite different from the result in the intact guinea pig where GR 113808 (1.0 mg/kg) did not affect either of the reflex indices. The present results indicate that mosapride enhanced the intrinsic R-R and R-IAS reflexes and functionally compensated for the deprivation of extrinsic innervation. The actions of mosapride were mediated through endogenously active, intrinsic 5-HT(4) receptors which may be post-synaptically located in the myenteric plexus of the anorectum.

  16. Graphics performance in rich Internet applications.

    PubMed

    Hoetzlein, Rama C

    2012-01-01

    Rendering performance for rich Internet applications (RIAs) has recently focused on the debate between using Flash and HTML5 for streaming video and gaming on mobile devices. A key area not widely explored, however, is the scalability of raw bitmap graphics performance for RIAs. Does Flash render animated sprites faster than HTML5? How much faster is WebGL than Flash? Answers to these questions are essential for developing large-scale data visualizations, online games, and truly dynamic websites. A new test methodology analyzes graphics performance across RIA frameworks and browsers, revealing specific performance outliers in existing frameworks. The results point toward a future in which all online experiences might be GPU accelerated.

  17. Optical fibres in the radiation environment of CERN

    NASA Astrophysics Data System (ADS)

    Guillermain, E.

    2017-11-01

    CERN, the European Organization for Nuclear Research (in Geneva, Switzerland), is home to a complex scientific instrument: the 27-kilometre Large Hadron Collider (LHC) collides beams of high-energy particles at close to the speed of light. Optical fibres are widely used at CERN, both in surface areas (e.g. for inter-building IT networks) and in the accelerator complex underground (e.g. for cryogenics, vacuum, safety systems). Optical fibres in the accelerator are exposed to mixed radiation fields (mainly composed of protons, pions, neutrons and other hadrons, gamma rays and electrons), with dose rates depending on the particular installation zone, and with radiation levels often significantly higher than those encountered in space. In the LHC and its injector chain radiation levels range from relatively low annual doses of a few Gy up to hundreds of kGy. Optical fibres suffer from Radiation Induced Attenuation (RIA, expressed in dB per unit length) that affect light transmission and which depends on the irradiation conditions (e.g. dose rate, total dose, temperature). In the CERN accelerator complex, the failure of an optical link can affect the proper functionality of control or monitoring systems and induce the interruption of the accelerator operation. The qualification of optical fibres for installation in critical radiation areas is therefore crucial. Thus, all optical fibre types installed in radiation areas at CERN are subject to laboratory irradiation tests, in order to evaluate their RIA at different total dose and dose rates. This allows the selection of the appropriate optical fibre type (conventional or radiation resistant) compliant with the requirements of each installation. Irradiation tests are performed in collaboration with Fraunhofer INT (irradiation facilities and expert team in Euskirchen, Germany). Conventional off-the-shelf optical fibres can be installed for optical links exposed to low radiation levels (i.e. annual dose typically below few kGy). Nevertheless, the conventional optical fibres must be carefully qualified as a spread in RIA of factor 10 is observed among optical fibres of different types and dopants. In higher radiation areas, special radiation resistant optical fibres are installed. For total dose above 1 kGy, the RIA of these special optical fibres is at least 10 times lower than the conventional optical fibres RIA at same irradiation conditions. 2400 km of these special radiation resistant optical fibres were recently procured at CERN. As part of this procurement process, a quality assurance plan including the irradiation testing of all 65 produced batches was set up. This presentation will review the selection process of the appropriate optical fibre types to be installed in the radiation environment of CERN. The methodology for choosing the irradiation parameters for the laboratory tests will be discussed together with an overview of the RIA of different optical fibre types under several irradiation conditions.

  18. Method of operating a thermoelectric generator

    DOEpatents

    Reynolds, Michael G; Cowgill, Joshua D

    2013-11-05

    A method for operating a thermoelectric generator supplying a variable-load component includes commanding the variable-load component to operate at a first output and determining a first load current and a first load voltage to the variable-load component while operating at the commanded first output. The method also includes commanding the variable-load component to operate at a second output and determining a second load current and a second load voltage to the variable-load component while operating at the commanded second output. The method includes calculating a maximum power output of the thermoelectric generator from the determined first load current and voltage and the determined second load current and voltage, and commanding the variable-load component to operate at a third output. The commanded third output is configured to draw the calculated maximum power output from the thermoelectric generator.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tu, J.I.; Brennan, J.; Stouffer, B.

    Fosinopril (SQ 28,555) is a member of a new chemical class of angiotensin converting enzyme inhibitors being developed by The Squibb Institute for Medical Research. During or following absorption, fosinopril, a prodrug, is hydrolyzed pharmacologically to the active diacid, SQ 27,519. A specific radioimmunoassay (RIA) for the measurement of SQ 27,519 in human serum has been developed. The assay utilizes a specific SQ 27,519 antibody, 125I-iodohistamine-SQ 27,519 radiolabel, and human serum standards. Satisfactory zero binding and assay sensitivity are achieved after a 2-h incubation at room temperature. Separation of the antibody-bound and free radiolabeled antigens is achieved by using polyethylenemore » glycol-goat anti-rabbit gamma globulin separant. Recovery efficiencies ranged from 97.2 to 109.4%. The assay exhibited little or no cross-reactivity with captopril. Cross-reactivities for prodrug (SQ 28,555) and phenolic SQ 27,519 were 5 and 9%, respectively. Intra-assay variability (3.3-5.6%) and interassay variability (7.1-6.6%) were observed. Linear regression analysis indicates that RIA and (14C) thin-layer radiochromatography (TLRC) methods gave a highly significant correlation (RIA = 1.0 (14C)TLRC + 0.17, r = 0.991). Pharmacokinetic profiles of patient sera containing SQ 27,519 obtained by RIA and (14C)TLRC are identical. The RIA has been used routinely in support of the bioavailability and pharmacokinetic studies of fosinopril in humans.« less

  20. Factorial Validity of the Reynolds Intellectual Assessment Scales for Referred Students

    ERIC Educational Resources Information Center

    Beaujean, A. Alexander; McGlaughlin, Sean M.; Margulies, Allison S.

    2009-01-01

    The Reynolds Intellectual Assessment Scales (RIAS) is a recently developed, individually administered psychometric instrument designed to measure general cognitive ability, as well as verbal (crystallized) intelligence, nonverbal (fluid) intelligence, and memory. Test reviewers have recommended the use of the RIAS despite the fact that, although…

  1. The Role of Relative Intrinsic Aspirations in Chinese Adolescents' Prosocial Behaviors

    ERIC Educational Resources Information Center

    Fu, Xinyuan; Liu, Xiaolan; Yang, Ying; Zhang, Mengyuan; Kou, Yu

    2018-01-01

    We examined Chinese adolescents' aspirations and explored the relationship between relative intrinsic aspirations (RIA) and prosocial behaviors and whether adolescents with different levels of RIA have different emphases on self- and other-oriented considerations during prosocial decision making. In Study 1, 236 participants were recruited and…

  2. Measurement of Steroids in Rats after Exposure to an Endocrine Disruptor: Mass Spectrometry and Radioimmunoassay Demonstrate Similar Results

    EPA Science Inventory

    Commercially available radioimmunoassays (RIAs) are frequently used in toxicological studies to evaluate effects of endocrine disrupting chemicals (EDCs) on steroidogenesis in rats. Currently there are limited data comparing steroid concentrations in rats as measured by RIAs to t...

  3. Cross-validation of commercial enzyme-linked immunosorbent assay and radioimmunoassay for porcine C-peptide concentration measurements in non-human primate serum.

    PubMed

    Gresch, Sarah C; Mutch, Lucas A; Janecek, Jody L; Hegstad-Davies, Rebecca L; Graham, Melanie L

    2017-09-01

    C-peptide concentration is widely used as a marker of insulin secretion and is especially relevant in evaluating islet graft function following transplantation, because its measurement is not confounded by the presence of exogenous insulin. To address the shortage of human islet donors, the use of porcine islets has been proposed as a possible solution and the stringent pig-to-non-human primate (NHP) model is often the most relevant for pre-clinical evaluation of the potential for diabetes reversal resulting from an islet xenograft. The Millipore radioimmunoassay (RIA) was exclusively used to measure porcine C-peptide (PCP) until 2013 when the assay was discontinued and subsequently a commercially available enzyme-linked immunosorbent assay (ELISA) from Mercodia has been widely adopted. Both assays have been used in pre-clinical trials evaluating the therapeutic potential of xenograft products in reversing diabetes in the pig-to-NHP model, to interpret data in a comparable way it may be useful to perform a harmonization of C-peptide measurements. We performed a method comparison by determining the PCP concentration in 620 serum samples collected from 20 diabetic cynomolgus macaques transplanted with adult porcine islets. All analyses were performed according to manufacturer instructions. With both assays, we demonstrated an acceptable detection limit, precision, and recovery. Linearity of the ELISA met acceptance criteria at all concentrations tested while linearity of the RIA only met acceptance criteria at five of the eight concentrations tested. The RIA had a detection limit of 0.16 ng/mL, and recovery ranged from 82% to 96% and met linearity acceptance criteria at 0.35 ng/mL and from 0.78 to 2.33 ng/mL. The ELISA had a detection limit of 0.03 ng/mL, and recovery ranged from 81% to 115% and met linearity acceptance criteria from 0.08 to 0.85 ng/mL. Both assays had intra-assay precision <11% and inter-assay precision <14%. PCP concentration measured by ELISA demonstrated a significant correlation with RIA (R 2 =.9721, P<.0001). This strong correlation supports use of the regression equation y=2.029x+0.0897 to transform ELISA data to RIA or inversely y=0.4930x-0.0456 to convert RIA data to ELISA for direct comparison between assays in the concentration range of 0-3.0 ng/mL. Measured C-peptide concentration was lower with the ELISA than with the RIA; individual measurements plotted against the averages of the pair demonstrated that the variability from the mean strongly depended on increasing concentration. Porcine C-peptide can be reliably measured in NHP serum using the Mercodia ELISA, making this assay interchangeable with the Millipore RIA. Inherent differences in antibody affinity and calibration factors may explain the lower ELISA values as compared to the RIA; however without access to a traceable reference standard, it is not possible to determine which assay is most accurate. Regression modeling resulted in a correction factor appropriate for conversion of ELISA data to RIA-equivalent data facilitating comparison of assay results longitudinally and between groups. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. The 1990 progress report and future plans

    NASA Technical Reports Server (NTRS)

    Friedland, Peter; Zweben, Monte; Compton, Michael

    1990-01-01

    This document describes the progress and plans of the Artificial Intelligence Research Branch (RIA) at ARC in 1990. Activities span a range from basic scientific research to engineering development and to fielded NASA applications, particularly those applications that are enabled by basic research carried out at RIA. Work is conducted in-house and through collaborative partners in academia and industry. Our major focus is on a limited number of research themes with a dual commitment to technical excellence and proven applicability to NASA short, medium, and long-term problems. RIA acts as the Agency's lead organization for research aspects of artificial intelligence, working closely with a second research laboratory at JPL and AI applications groups at all NASA centers.

  5. Racial Identity and the MMPI in African American Male College Students.

    ERIC Educational Resources Information Center

    Whatley, P. Richard; Allen, James; Dana, Richard H.

    2003-01-01

    Examines the relation of the Minnesota Multiphasic Personality Inventory (MMPI) to the Racial Identity Attitude Scale-Black, Short Form (RIAS-B) was examined among 50 African American male college students Results indicated RIAS-B scale scores functioned as predictors of MMPI scale scores. Implications of these findings for MMPI-2 research with…

  6. Alternative Education Spaces in Mexico

    ERIC Educational Resources Information Center

    Gray, Chloe

    2010-01-01

    This article explores the architecture of the Red de Innovacion y Aprendizaje (RIA), or Learning and Innovation Network, which is a group of education centres that provide access to computers, the Internet and quality education to low-income communities in Mexico. The RIA began in May 2009 when ten pilot centres were opened in four municipalities…

  7. Rich internet application system for patient-centric healthcare data management using handheld devices.

    PubMed

    Constantinescu, L; Pradana, R; Kim, J; Gong, P; Fulham, Michael; Feng, D

    2009-01-01

    Rich Internet Applications (RIAs) are an emerging software platform that blurs the line between web service and native application, and is a powerful tool for handheld device deployment. By democratizing health data management and widening its availability, this software platform has the potential to revolutionize telemedicine, clinical practice, medical education and information distribution, particularly in rural areas, and to make patient-centric medical computing a reality. In this paper, we propose a telemedicine application that leverages the ability of a mobile RIA platform to transcode, organise and present textual and multimedia data, which are sourced from medical database software. We adopted a web-based approach to communicate, in real-time, with an established hospital information system via a custom RIA. The proposed solution allows communication between handheld devices and a hospital information system for media streaming with support for real-time encryption, on any RIA enabled platform. We demonstrate our prototype's ability to securely and rapidly access, without installation requirements, medical data ranging from simple textual records to multi-slice PET-CT images and maximum intensity (MIP) projections.

  8. Optimization of the radioimmunoassays for measuring fentanyl and alfentanil in human serum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schuettler, J.; White, P.F.

    Measurement of serum fentanyl and alfentanil concentrations by radioimmunoassay (RIA) may result in significant errors and high variability when the technique described in the available fentanyl and alfentanil RIA kits is used. The authors found a 29-94% overestimation of measured fentanyl and alfentanil serum levels when 3H-fentanyl or 3H-alfentanil was added lastly to the mixture of antiserum and sample. This finding is related to a reduction in binding sites for the labeled compounds after preincubation of sample and antiserum. If this sequence is used, it becomes necessary to extend the incubation period up to 6 h for fentanyl and upmore » to 10 h for alfentanil in order to achieve equilibration between unlabeled and labeled drug with respect to antiserum binding. However, when antiserum is added lastly to the mixture of sample and labeled drug, measurement accuracy and precision for fentanyl and alfentanil serum concentrations are enhanced markedly. In addition, it is important to perform the calibration curves and sample measurements using the same medium (i.e., serum alone or a serum/buffer dilution). In summary, to optimize the RIA for fentanyl and alfentanil, the authors recommend the following: 1) adding the antiserum lastly to the mixture of sample and labeled drug; 2) performing calibration curves using patient's blank serum when possible; 3) carefully examining and standardizing each step of the RIA procedure to reduce variability, and, finally; 4) comparing results with those of other established RIA laboratories.« less

  9. Sensitive and specific radioimmunoassay for fialuridine: initial assessment of pharmacokinetics after single oral doses to healthy volunteers.

    PubMed Central

    Bowsher, R R; Compton, J A; Kirkwood, J A; Place, G D; Jones, C D; Mabry, T E; Hyslop, D L; Hatcher, B L; DeSante, K A

    1994-01-01

    Fialuridine (FIAU) is a halogen-substituted analog of thymidine that was undergoing clinical investigation as a drug for the treatment of chronic hepatitis B viral infection. However, clinical trials of FIAU were terminated after adverse events occurred following chronic oral administration. Prior to the termination of clinical trials, a sensitive assay was needed for the measurement of FIAU because of the anticipated low dose administered to patients. We therefore undertook the development of a radioimmunoassay (RIA). A specific antiserum was raised in rabbits following immunization with a 5'-O-hemisuccinate analog of FIAU coupled to keyhole limpet hemocyanin. Radiolabeled FIAU was synthesized by a destannylation procedure by using sodium [125I]iodide. We developed a competitive-binding procedure and used precipitation with polyethylene glycol as the method for separating the bound and free forms of FIAU. The RIA is sensitive (0.2 ng/ml), specific (negligible interference from known metabolites and endogenous nucleosides), and reproducible (interassay coefficients of variation range from 5 to 19.7% for serum controls). We used the RIA to assess the pharmacokinetics of FIAU in healthy adult volunteers following administration of a single 5-mg oral dose. The sensitivity of the RIA permitted the detection of a prolonged elimination phase for FIAU in healthy volunteers and dogs, with mean elimination half-lives of 29.3 and 35.3 h, respectively. We conclude the RIA is a valid method for the quantification of FIAU in biological fluids. PMID:7811032

  10. Resultados a longo prazo da angioplastia de artérias renais com stent na doença aterosclerótica: revisão sistemática

    PubMed Central

    Siqueira, Daniel Emilio Dalledone; Guillaumon, Ana Terezinha

    2017-01-01

    Resumo A doença renovascular aterosclerótica é a principal causa de hipertensão secundária. A história natural da doença demonstra taxas de progressão de 4 a 12% ao ano. Entre os métodos de tratamento existe a angioplastia com stent de artérias renais; porém, poucos estudos clínicos demonstraram seus resultados a longo prazo. Esta revisão sistemática da literatura se propõe a apresentar os resultados a longo prazo (acima de 24 meses) da angioplastia com stent de artérias renais na doença aterosclerótica em relação à função renal e aos níveis pressóricos no controle da hipertensão. Foi realizada uma ampla pesquisa, utilizando os termos apropriados, nas bases de dados LILACS, EMBASE, SCIELO, Cochrane Library e MEDLINE. De um total de 2.170 referências, apenas sete artigos contemplavam todos os critérios de inclusão. Conclui-se que, a longo prazo, há uma estabilização da função renal, redução dos níveis pressóricos e diminuição do número de classes de medicamentos anti-hipertensivos. PMID:29930639

  11. Comparison between smaller ruptured intracranial aneurysm and larger un-ruptured intracranial aneurysm: gene expression profile analysis.

    PubMed

    Li, Hao; Li, Haowen; Yue, Haiyan; Wang, Wen; Yu, Lanbing; ShuoWang; Cao, Yong; Zhao, Jizong

    2017-07-01

    As it grows in size, an intracranial aneurysm (IA) is prone to rupture. In this study, we compared two extreme groups of IAs, ruptured IAs (RIAs) smaller than 10 mm and un-ruptured IAs (UIAs) larger than 10 mm, to investigate the genes involved in the facilitation and prevention of IA rupture. The aneurismal walls of 6 smaller saccular RIAs (size smaller than 10 mm), 6 larger saccular UIAs (size larger than 10 mm) and 12 paired control arteries were obtained during surgery. The transcription profiles of these samples were studied by microarray analysis. RT-qPCR was used to confirm the expression of the genes of interest. In addition, functional group analysis of the differentially expressed genes was performed. Between smaller RIAs and larger UIAs, 101 genes and 179 genes were significantly over-expressed, respectively. In addition, functional group analysis demonstrated that the up-regulated genes in smaller RIAs mainly participated in the cellular response to metal ions and inorganic substances, while most of the up-regulated genes in larger UIAs were involved in inflammation and extracellular matrix (ECM) organization. Moreover, compared with control arteries, inflammation was up-regulated and muscle-related biological processes were down-regulated in both smaller RIAs and larger UIAs. The genes involved in the cellular response to metal ions and inorganic substances may facilitate the rupture of IAs. In addition, the healing process, involving inflammation and ECM organization, may protect IAs from rupture.

  12. Memória fonológica em crianças bilíngues bimodais e crianças com implante coclear

    PubMed Central

    de Quadros, Ronice Müller; Cruz, Carina Rebello; Pizzio, Aline Lemos

    2014-01-01

    RESUMO Este estudo comparou o desempenho de crianças bilíngues bimodais ouvintes (filhas de pais surdos) e crianças surdas usuárias de implante coclear (filhas de pais surdos e de pais ouvintes), com diferentes contextos de acesso à Língua Brasileira de Sinais (Libras), em tarefas que envolvem memória fonologica. Os testes utilizados foram: Teste de Pseudopalavras (Santos e Bueno, 2003) e Teste de Pseudosinais (desenvolvido pelos pesquisadores responsáveis pelo Projeto ‘Desenvolvimento Bilíngue Bimoda’). Além disso, foram incluídos dois grupos de controle, formados por crianças surdas (usuarias de Libras), e adultos bilíngues bimodais ouvintes. Na análise dos resultados, em relação ao desempenho entre os dois grupos testados foi constatado que o grupo de crianças bilíngues bimodais ouvintes apresentou desempenho superior, nos dois testes. No entanto, ao ser analisado o desempenho da criança surda usuaria de implante coclear, filha de pais surdos, que possui acesso irrestrito à Libras e comparado com o das crianças surdas usuárias de implante coclear, que possuem acesso restrito à Libras, foi constatado que o seu desempenho foi semelhante ao do grupo de crianças bilíngues bimodais ouvintes. As crianças surdas usuárias de implante coclear com acesso restrito à Libras e, portanto, com acesso maior ao Português apresentaram escores mais baixos nas tarefas, principalmente do teste em Português. Os resultados sugerem que as crianças surdas usuárias de implante coclear em processo de aquisição da línguagem podem se beneficiar com o acesso irrestrito à Libras, atingindo inclusive desempenho semelhante a de crianças bilíngues bimodais ouvintes. PMID:25110473

  13. Millennial surface water dynamics in the Ria de Vigo during the last 3,000 years as revealed by coccolithophores and biomarkers

    NASA Astrophysics Data System (ADS)

    Alvarez, M. C.; Flores, J. A.; Sierro, F. J.; Diz, P.; Frances, G.; Pelejero, C.; Grimalt, J.

    2003-04-01

    A combined study of coccolithophore assemblages and biomarkers in gravity core VIR-18 (380 cm long) located in the Ria de Vigo (42°14.07 N, 8°47.37W) at a water depth of 45 m situated in the Ria de Vigo (SW Spain) has allowed us to reconstruct the paleoenvironmental conditions for the last 3000 years. The quantitative distribution of coccolithophore species points to three different intervals along the core, dated by AMS radiocarbon measurements. A first interval (I; ca. 975 BC-252 AD), characterized by high abundances of Calcidiscus leptoporus and Gephyrocapsa muellerae, features moderate temperatures, suggesting a transition from a warmer to a cooler period. A second interval (II; ca. 252-1368 AD), characterized by the dominance of Coccolithus pelagicus, Helicosphaera carteri and Syracosphaera spp., and a high concentration of hexacosanol linked to terrestrial input, is interpreted as having been a humid period with prevailing runoff. The third interval (III; ca. 1368 AD-1950) is characterized by a high abundance of Gephyrocapsa oceanica, high values of alkenones and low values of hexacosanol, and is interpreted as a period of dominance of oceanic conditions within the Ria. Taking into account the ocean-atmospheric system existing in the region studied, we propose an alternance in the North Atlantic Oscillation (NAO) at millennial time scale. A developed upwelling and a good Ria-ocean connection in the warmer Interval I, suggest a NAO+ phase influenced by a Hypsithermal period. The occurrence of the humid and relatively warm Interval II is consistent with a negative phase in the NAO, as well as a relative restriction in ocean-Ria exchange. Interval III, which was dryer and more productive, suggests the dominance of a positive phase in the NAO, with a more intense oceanic connection and more energized upwelling.

  14. System and method employing a minimum distance and a load feature database to identify electric load types of different electric loads

    DOEpatents

    Lu, Bin; Yang, Yi; Sharma, Santosh K; Zambare, Prachi; Madane, Mayura A

    2014-12-23

    A method identifies electric load types of a plurality of different electric loads. The method includes providing a load feature database of a plurality of different electric load types, each of the different electric load types including a first load feature vector having at least four different load features; sensing a voltage signal and a current signal for each of the different electric loads; determining a second load feature vector comprising at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the different electric loads; and identifying by a processor one of the different electric load types by determining a minimum distance of the second load feature vector to the first load feature vector of the different electric load types of the load feature database.

  15. Phalange Tactile Load Cell

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor); Linn, Douglas Martin (Inventor); Platt, Robert (Inventor); Griffith, Bryan Kristian (Inventor)

    2010-01-01

    A tactile load cell that has particular application for measuring the load on a phalange in a dexterous robot system. The load cell includes a flexible strain element having first and second end portions that can be used to mount the load cell to the phalange and a center portion that can be used to mount a suitable contact surface to the load cell. The strain element also includes a first S-shaped member including at least three sections connected to the first end portion and the center portion and a second S-shaped member including at least three sections coupled to the second end portion and the center portion. The load cell also includes eight strain gauge pairs where each strain gauge pair is mounted to opposing surfaces of one of the sections of the S-shaped members where the strain gauge pairs provide strain measurements in six-degrees of freedom.

  16. Validation of an enzyme-linked immunosorbent assay (ELISA) for the measurement of canine S100A12.

    PubMed

    Heilmann, Romy M; Cranford, Shannon M; Ambrus, Andy; Grützner, Niels; Schellenberg, Stefan; Ruaux, Craig G; Suchodolski, Jan S; Steiner, Jörg M

    2016-03-01

    Canine S100 calcium-binding protein A12 (cS100A12) shows promise as biomarker of inflammation in dogs. A previously developed cS100A12-radioimmunoassay (RIA) requires radioactive tracers and is not sensitive enough for fecal cS100A12 concentrations in 79% of tested healthy dogs. An ELISA assay may be more sensitive than RIA and does not require radioactive tracers. The purpose of the study was to establish a sandwich ELISA for serum and fecal cS100A12, and to establish reference intervals (RI) for normal healthy canine serum and feces. Polyclonal rabbit anti-cS100A12 antibodies were generated and tested by Western blotting and immunohistochemistry. A sandwich ELISA was developed and validated, including accuracy and precision, and agreement with cS100A12-RIA. The RI, stability, and biologic variation in fecal cS100A12, and the effect of corticosteroids on serum cS100A12 were evaluated. Lower detection limits were 5 μg/L (serum) and 1 ng/g (fecal), respectively. Intra- and inter-assay coefficients of variation were ≤ 4.4% and ≤ 10.9%, respectively. Observed-to-expected ratios for linearity and spiking recovery were 98.2 ± 9.8% (mean ± SD) and 93.0 ± 6.1%, respectively. There was a significant bias between the ELISA and the RIA. The RI was 49-320 μg/L for serum and 2-484 ng/g for fecal cS100A12. Fecal cS100A12 was stable for 7 days at 23, 4, -20, and -80°C; biologic variation was negligible but variation within one fecal sample was significant. Corticosteroid treatment had no clinically significant effect on serum cS100A12 concentrations. The cS100A12-ELISA is a precise and accurate assay for serum and fecal cS100A12 in dogs. © 2016 American Society for Veterinary Clinical Pathology.

  17. Photovoltaic power converter system with a controller configured to actively compensate load harmonics

    DOEpatents

    de Rooij, Michael Andrew; Steigerwald, Robert Louis; Delgado, Eladio Clemente

    2008-12-16

    Photovoltaic power converter system including a controller configured to reduce load harmonics is provided. The system comprises a photovoltaic array and an inverter electrically coupled to the array to generate an output current for energizing a load connected to the inverter and to a mains grid supply voltage. The system further comprises a controller including a first circuit coupled to receive a load current to measure a harmonic current in the load current. The controller includes a second circuit to generate a fundamental reference drawn by the load. The controller further includes a third circuit for combining the measured harmonic current and the fundamental reference to generate a command output signal for generating the output current for energizing the load connected to the inverter. The photovoltaic system may be configured to compensate harmonic currents that may be drawn by the load.

  18. Development of immunoassays for human urokinase

    NASA Technical Reports Server (NTRS)

    Atassi, M. Zouhair

    1988-01-01

    Radioimmune assays (RIA) and enzyme linked immune assays for measurement of pro-urokinase and the two active forms of the enzyme were developed. Polyclonal and monoclonal antibodies, with desired specificities against preselected synthetic regions of urokinase (UK), were obtained by immunization with the respective synthetic peptides and used to develop RIA for zymogen and the two activated forms of UK.

  19. A Multitrait-Multimethod Examination of the Reynolds Intellectual Assessment Scales in a College Sample

    ERIC Educational Resources Information Center

    Beaujean, A. Alexander; Firmin, Michael W.; Michonski, Jared D.; Berry, Theodore; Johnson, Courtney

    2010-01-01

    This study assessed trait validity of the Reynolds Intellectual Assessment Scales' (RIAS) Verbal Index (VIX) and Nonverbal Index (NIX) scores in a group of college students. Using both observation of patterns and latent variable modeling of a multitrait-multimethod correlation/covariance matrix, the results indicate that the RIAS VIX scores…

  20. Clustering high dimensional data using RIA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aziz, Nazrina

    2015-05-15

    Clustering may simply represent a convenient method for organizing a large data set so that it can easily be understood and information can efficiently be retrieved. However, identifying cluster in high dimensionality data sets is a difficult task because of the curse of dimensionality. Another challenge in clustering is some traditional functions cannot capture the pattern dissimilarity among objects. In this article, we used an alternative dissimilarity measurement called Robust Influence Angle (RIA) in the partitioning method. RIA is developed using eigenstructure of the covariance matrix and robust principal component score. We notice that, it can obtain cluster easily andmore » hence avoid the curse of dimensionality. It is also manage to cluster large data sets with mixed numeric and categorical value.« less

  1. Doença cística adventicial da artéria poplítea: relato de caso

    PubMed Central

    de Oliveira, Julio Cesar Peclat; Barreto, Fernando Tebet Ramos; Souza, Diogo Di Battista de Abreu e; Fonseca, João Marcos Fonseca e; Chimelli, Bernardo de Castro Abi Ramia; Peclat, Ana Paula Rolim Maia; Marques, Marcos Arêas; Fiorelli, Stenio Karlos Alvim

    2018-01-01

    Resumo A doença cística adventicial da artéria poplítea é uma doença pouco frequente, que deve ser considerada no diagnóstico diferencial de pacientes jovens com claudicação intermitente e sem fatores de risco para doença arterial periférica aterosclerótica. Apresentamos um caso de claudicação intermitente de membros inferiores em paciente masculino de 51 anos no qual essa doença foi diagnosticada. Foi submetido a ressecção do segmento de artéria comprometido e interposição de safena autóloga ipsilateral. Discutimos alternativas diagnósticas e terapêuticas. PMID:29930682

  2. Seismic behavior of circular reinforced concrete bridge columns under combined loading including torsion.

    DOT National Transportation Integrated Search

    2009-12-01

    Reinforced concrete (RC) columns of skewed and curved bridges with unequal spans and column heights can be subjected to : combined loading including axial, flexure, shear, and torsion loads during earthquakes. The combination of axial loads, shear : ...

  3. Remote actuated cryocooler for superconducting generator and method of assembling the same

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stautner, Ernst Wolfgang; Haran, Kiruba Sivasubramaniam; Fair, Ruben Jeevanasan

    2017-02-14

    In one embodiment, a cryocooler assembly for cooling a heat load is provided. The cryocooler assembly includes a vacuum vessel surrounding the heat load and a cryocooler at least partially inserted into the vacuum vessel, the cryocooler including a coldhead. The assembly further includes an actuator coupled to the cryocooler. The actuator is configured to translate the cryocooler coldhead into thermal engagement with the heat load and to maintain constant pressure of the coldhead against the heat load to facilitate maintaining thermal engagement with the heat load as the heat load shrinks during a cool down process.

  4. Method and system employing graphical electric load categorization to identify one of a plurality of different electric load types

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Yi; Du, Liang

    A system for different electric loads includes sensors structured to sense voltage and current signals for each of the different electric loads; a hierarchical load feature database having a plurality of layers, with one of the layers including a plurality of different load categories; and a processor. The processor acquires voltage and current waveforms from the sensors for a corresponding one of the different electric loads; maps a voltage-current trajectory to a grid including a plurality of cells, each of which is assigned a binary value of zero or one; extracts a plurality of different features from the mapped gridmore » of cells as a graphical signature of the corresponding one of the different electric loads; derives a category of the corresponding one of the different electric loads from the database; and identifies one of a plurality of different electric load types for the corresponding one of the different electric loads.« less

  5. Reinterpretation of the Quaternary sedimentary infill of the Ría de Vigo, NW Iberian Peninsula, as a compound incised valley

    NASA Astrophysics Data System (ADS)

    Martínez-Carreño, N.; García-Gil, S.

    2017-10-01

    Seismic data have been used to investigate the stratigraphy of the Galician rias for more than two decades. Here, we present a new interpretation of the sedimentary infill of an incised valley (Ría de Vigo, NW Iberian Peninsula), based on high-resolution seismic profiles, core sediment analysis, and radiocarbon 14C data. The new data indicate that the stratigraphic architecture of the Galician rias result from multiple incision/infill phases and, therefore, they are reclassified as compound rather than simple incised valleys. Seven seismic units were identified: one of Tertiary age (U1), four of Pleistocene age (U2-U5) which are interpreted as 4th-order sequences deposited between MIS 11 and MIS 2, and Late Pleistocene (U6) and Holocene (U7) units corresponding with post-glacial sedimentation. The sedimentary infill overlies a highly faulted irregular granitic and metamorphic basement; the inherited morphology is shown to be important for controlling the pathway and evolution of the fluvial network as well as preservation of the sedimentary deposits during several glacial/interglacial cycles. The presence of a rocky barrier at the mouth of the ria is a distinctive feature that conditions sedimentation and exchange of sediment between the ria and the adjacent shelf. For the first time, faults and tilted blocks affecting Late Pleistocene (MIS 3) deposits have been identified. The new data presented here provide the opportunity to reconstruct the evolution of the sedimentary infill of a ria, with especially high-resolution during the last post-glacial transgression.

  6. Serodiagnosis of infectious mononucleosis with a bovine erythrocyte glycoprotein.

    PubMed

    Fletcher, M A; Klimas, N G; Latif, Z A; Caldwell, K E

    1983-09-01

    A glycoprotein from bovine erythrocyte membrane was evaluated in two immunoassays as a reagent for the serodiagnosis of infectious mononucleosis (IM). We previously reported that a partially purified preparation of this glycoprotein, when attached to latex beads, agglutinated in the presence of IM heterophile antibody. In the present study, we used a highly purified form of the glycoprotein both as an agglutinating reagent, covalently bound to latex, and in a solid-phase sandwich-type radioimmunoassay (RIA) for IM antibody detection in a larger population of patients. We tested serum samples from college students with symptoms suggestive of IM with the latex reagent (143 samples) and with the RIA (245 samples). Correlation of these two tests, both with each other and with the classical differentially absorbed, agglutination tests for Paul-Bunnell antibody in IM sera, using fresh sheep or horse cells, was excellent (greater than 97% agreement). The new tests also corresponded in most cases with a rapid, unabsorbed preserved horse erythrocyte slide test. However, in this study of 245 samples, both apparent false-positives (5 samples) and apparent false-negatives (3 samples) were observed with this slide test. In conclusion, we found that the bovine glycoprotein as a reagent can facilitate the diagnosis of IM, giving results comparable to those with erythrocyte agglutination tests on differentially absorbed sera. The advantages are ease and speed of performance (latex test), potential for automation (RIA test), stability and uniformity of the glycoprotein reagent (latex and RIA tests), and most importantly, the ability to use unabsorbed sera (latex and RIA tests).

  7. Probabilistic load simulation: Code development status

    NASA Astrophysics Data System (ADS)

    Newell, J. F.; Ho, H.

    1991-05-01

    The objective of the Composite Load Spectra (CLS) project is to develop generic load models to simulate the composite load spectra that are included in space propulsion system components. The probabilistic loads thus generated are part of the probabilistic design analysis (PDA) of a space propulsion system that also includes probabilistic structural analyses, reliability, and risk evaluations. Probabilistic load simulation for space propulsion systems demands sophisticated probabilistic methodology and requires large amounts of load information and engineering data. The CLS approach is to implement a knowledge based system coupled with a probabilistic load simulation module. The knowledge base manages and furnishes load information and expertise and sets up the simulation runs. The load simulation module performs the numerical computation to generate the probabilistic loads with load information supplied from the CLS knowledge base.

  8. Integrative assessment of coastal marine pollution in the Bay of Santander and the Upper Galician Rias

    NASA Astrophysics Data System (ADS)

    Rial, Diego; León, Víctor M.; Bellas, Juan

    2017-12-01

    Sediments from the Rias of A Coruña, Ferrol, Betanzos and Ares (n = 26) and the Bay of Santander (n = 11) were sampled in July 2012. The concentration of organic contaminants in sediment elutriates (CBs, PAHs, pesticides and personal care products) and sea urchin (Paracentrotus lividus) embryotoxicity were assessed. Relevant concentrations of organic pollutants were detected in the elutriates (ΣContaminants < 400 ng/L) but their interpretation in terms of the observed toxicity was not straightforward. A clear gradient of toxicity from the inner to the outer areas of the Bay of Santander was observed. Sediment elutriates from three stations situated close to the city of A Coruña showed moderate toxicity values, whereas sediment elutriates from the Rias of Ares and Betanzos showed no marked toxicity. Stations located close to the city of Ferrol showed moderate to high toxicity, which is indicative of a nearby source of contamination. On the contrary, the outer area of the Ria of Ferrol was classified as "Good" according to the calculated toxic units. These results allowed for an integrative assessment of the environmental quality of the studied areas.

  9. The Mechanical Response of Advanced Claddings during Proposed Reactivity Initiated Accident Conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cinbiz, Mahmut N; Brown, Nicholas R; Terrani, Kurt A

    2017-01-01

    This study investigates the failure mechanisms of advanced nuclear fuel cladding of FeCrAl at high-strain rates, similar to design basis reactivity initiated accidents (RIA). During RIA, the nuclear fuel cladding was subjected to the plane-strain to equibiaxial tension strain states. To achieve those accident conditions, the samples were deformed by the expansion of high strength Inconel alloy tube under pre-specified pressure pulses as occurring RIA. The mechanical response of the advanced claddings was compared to that of hydrided zirconium-based nuclear fuel cladding alloy. The hoop strain evolution during pressure pulses were collected in situ; the permanent diametral strains of bothmore » accident tolerant fuel (ATF) claddings and the current nuclear fuel alloys were determined after rupture.« less

  10. Design of Grid Portal System Based on RIA

    NASA Astrophysics Data System (ADS)

    Cao, Caifeng; Luo, Jianguo; Qiu, Zhixin

    Grid portal is an important branch of grid research. In order to solve the weak expressive force, the poor interaction, the low operating efficiency and other insufficiencies of the first and second generation of grid portal system, RIA technology was introduced to it. A new portal architecture was designed based on RIA and Web service. The concrete realizing scheme of portal system was presented by using Adobe Flex/Flash technology, which formed a new design pattern. In system architecture, the design pattern has B/S and C/S superiorities, balances server and its client side, optimizes the system performance, realizes platform irrelevance. In system function, the design pattern realizes grid service call, provides client interface with rich user experience, integrates local resources by using FABridge, LCDS, Flash player and some other components.

  11. Determination of Energy Independent Neutron Densities using Dirac Phenomenology based on the RIA

    NASA Astrophysics Data System (ADS)

    Clark, B. C.; Kerr, L. J.; Hama, S.; Mercer, R. L.

    2002-04-01

    A new method for extracting neutron densities from intermediate energy elastic proton-nucleus scattering observables using a global Dirac phenomenological (DP) approach based on the Relativistic Impulse Approximation (RIA) is presented. (B. C. Clark, et al.) BAPS Vol 46, No. 7 pg.139, 2001. We have considered data sets for ^40Ca, ^48Ca and ^208Pb and energies from 500 MeV to 1040 MeV. The global fits are successful in reproducing the data and in predicting data sets not included in the analysis. Using this global DP approach we have obtained energy independent neutron densities. The vector point proton density distribution, ρ^p_v, is determined from the empirical charge density after unfolding the proton form factor. The other densities, ρ^n_v, ρ^p_s, ρ^n_s, are parameterized using the cosh form given in our paper on global DP optical potentials.(E. D. Cooper, et al.) Phys Rev. 47C, pg. 297, 1993 Neutron skin thicknesses extracted using the global analysis are compared to predictions from theoretical models.

  12. System and method employing a self-organizing map load feature database to identify electric load types of different electric loads

    DOEpatents

    Lu, Bin; Harley, Ronald G.; Du, Liang; Yang, Yi; Sharma, Santosh K.; Zambare, Prachi; Madane, Mayura A.

    2014-06-17

    A method identifies electric load types of a plurality of different electric loads. The method includes providing a self-organizing map load feature database of a plurality of different electric load types and a plurality of neurons, each of the load types corresponding to a number of the neurons; employing a weight vector for each of the neurons; sensing a voltage signal and a current signal for each of the loads; determining a load feature vector including at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the loads; and identifying by a processor one of the load types by relating the load feature vector to the neurons of the database by identifying the weight vector of one of the neurons corresponding to the one of the load types that is a minimal distance to the load feature vector.

  13. The Impacts of a Scalable Intervention on the Language and Literacy Development of Rural Pre-Kindergartners

    ERIC Educational Resources Information Center

    Mashburn, Andrew; Justice, Laura M.; McGinty, Anita; Slocum, Laura

    2016-01-01

    Read It Again (RIA) is a curriculum for pre-kindergarten (pre-K) classrooms that targets children's development of language and literacy skills. A cluster randomized trial was conducted in which 104 pre-K classrooms in the Appalachian region of the United States were randomly assigned to one of three study conditions: Control (n = 30), RIA only…

  14. A Comparison of Low IQ Scores from the Reynolds Intellectual Assessment Scales and the Wechsler Adult Intelligence Scale--Third Edition

    ERIC Educational Resources Information Center

    Umphress, Thomas B.

    2008-01-01

    Twenty people with suspected intellectual disability took the Reynolds Intellectual Assessment Scales (RIAS; C. R. Reynolds & R. W. Kamphaus, 1998) and the Wechsler Adult Intelligence Scale--3rd Edition (WAIS-III; D. Wechsler, 1997) to see if the 2 IQ tests produced comparable results. A t test showed that the RIAS Composite Intelligence Index…

  15. Language and Literacy Curriculum Supplement for Preschoolers Who Are Academically At Risk: A Feasibility Study

    ERIC Educational Resources Information Center

    Justice, Laura M.; McGinty, Anita S.; Cabell, Sonia Q.; Kilday, Carolyn R.; Knighton, Kathy; Huffman, Ginger

    2010-01-01

    Purpose: The potential benefit that a low-cost scripted language and literacy supplemental curriculum titled "Read It Again!" (RIA; L. M. Justice, A. S. McGinty, A. R. Beckman, & C. R. Kilday, 2006) may have on preschool-age children's skills was explored. RIA was developed to meet the needs of preschool educators who may not have access to…

  16. Serum bioactive and immunoreactive luteinizing hormone and follicle-stimulating hormone levels in women with cycle abnormalities, with or without polycystic ovarian disease.

    PubMed

    Fauser, B C; Pache, T D; Lamberts, S W; Hop, W C; de Jong, F H; Dahl, K D

    1991-10-01

    Serum steroid, gonadotropin, and alpha-subunit levels were assessed in 35 women with cycle abnormalities [11 with and 24 without polycystic ovarian disease (PCOD) according to strict clinical and biochemical criteria] and 8 regularly cycling women in the early (cycle day 3 or 4) and mid (cycle day 7 or 8) follicular phase. LH and FSH levels were estimated using two immunological techniques [RIA and immunoradiometric assay (IRMA)] and in vitro bioassays (BIO), using mouse Leydig cells and rat granulosa cells, respectively. In PCOD patients mean alpha-subunit, free androgen index [FAI; testosterone x 100/sex hormone-binding globulin (SHBG)], androstenedione, estrone, and estradiol (E2) were significantly elevated compared to levels in the early follicular phase of control cycles and non-PCOD patients. In addition, in PCOD patients mean IRMA-LH and RIA-LH levels were distinctly increased (2.8- to 3.6 fold, respectively; both comparisons, P less than 0.001) compared to control values, but in the same order of magnitude (1.3- to 1.4-fold increments) as that in non-PCOD patients. However, the median BIO-LH level in PCOD patients was 5.9-fold higher than that in non-PCOD patients and 4.0-fold higher than the BIO-LH in the early follicular phase of control women. Consequently, the median BIO/IRMA-LH ratio was 4.8-fold higher in PCOD patients compared to non-PCOD patients. In women with cycle abnormalities, individual BIO/IRMA-LH ratios correlated with BIO-LH (rs = 0.48), FAI (rs = 0.39), free estrogens (E2/SHBG ratios; rs = 0 0.47), and dehydroepiandrosterone sulfate (rs = 0.60) concentrations. Mean IRMA-, RIA-, and BIO-FSH levels and BIO/IRMA-FSH ratios were not significantly different when various groups were compared. Although RIA- and IRMA-LH levels showed good correlation (rs = 0.88), RIA-LH levels were consistently higher, resulting in distinctly higher RIA-LH/FSH ratios (mean, 4.5) compared to IRMA-LH/FSH ratios (median, 1.8) in PCOD patients.(ABSTRACT TRUNCATED AT 400 WORDS)

  17. Leadership success within disaster restoration projects.

    PubMed

    Rapp, Randy R; Baroudi, Bassam

    2014-01-01

    Successful project managers draw their performance from essential leadership traits, as guided by their core values.Within disaster recovery, contractors who mitigate, repair, and reconstruct the built environment are often faced with challenges exceeding the norm. The effective leader is commonly expected to consider stakeholder motivations within distressing situations as well as other external and environmental factors when seeking to lead the project team to successful outcomes. This research is most concerned with leadership within the context of disaster restoration of the built environment. Its stimulus comes from the Restoration Industry Association (RIA)'s efforts to highlight leadership traits and core values for its Certified Restorer Body of Knowledge but would be of value to others associated with disaster recovery operations. Among organizations whose membership includes thousands of practitioners who restore and reconstruct the built environment after disasters, the RIA is the only one yet to formally and substantially research which core values and leader traits are deemed critical for the success of efforts to manage the means and methods applied on recovery job sites. Forty-six seasoned disaster restoration industry project professionals voluntarily responded to a survey questionnaire that sought their opinions about the traits and core values that they consider most important for successful disaster restoration project leadership. The most important leader traits were effective communication, professional competence, and leadership by example. The most important restoration industry values were integrity, compassion, and trustworthiness. The recognized imperative of compassion was unexpected in light of stereotypes often associated with construction-related contractors. This and other findings permit disaster response and recovery stakeholders to better understand qualities they should wish to see in leaders of contractor organizations, which they hire to restore and reconstruct the built environment after catastrophic events.

  18. Do Electrochemiluminescence Assays Improve Prediction of Time to Type 1 Diabetes in Autoantibody-Positive TrialNet Subjects?

    PubMed Central

    Fouts, Alexandra; Pyle, Laura; Yu, Liping; Miao, Dongmei; Michels, Aaron; Krischer, Jeffrey; Sosenko, Jay; Gottlieb, Peter

    2016-01-01

    OBJECTIVE To explore whether electrochemiluminescence (ECL) assays can help improve prediction of time to type 1 diabetes in the TrialNet autoantibody-positive population. RESEARCH DESIGN AND METHODS TrialNet subjects who were positive for one or more autoantibodies (microinsulin autoantibody, GAD65 autoantibody [GADA], IA-2A, and ZnT8A) with available ECL-insulin autoantibody (IAA) and ECL-GADA data at their initial visit were analyzed; after a median follow-up of 24 months, 177 of these 1,287 subjects developed diabetes. RESULTS Univariate analyses showed that autoantibodies by radioimmunoassays (RIAs), ECL-IAA, ECL-GADA, age, sex, number of positive autoantibodies, presence of HLA DR3/4-DQ8 genotype, HbA1c, and oral glucose tolerance test (OGTT) measurements were all significantly associated with progression to diabetes. Subjects who were ECL positive had a risk of progression to diabetes within 6 years of 58% compared with 5% for the ECL-negative subjects (P < 0.0001). Multivariate Cox proportional hazards models were compared, with the base model including age, sex, OGTT measurements, and number of positive autoantibodies by RIAs. The model with positivity for ECL-GADA and/or ECL-IAA was the best, and factors that remained significantly associated with time to diabetes were area under the curve (AUC) C-peptide, fasting C-peptide, AUC glucose, number of positive autoantibodies by RIAs, and ECL positivity. Adding ECL to the Diabetes Prevention Trial risk score (DPTRS) improved the receiver operating characteristic curves with AUC of 0.83 (P < 0.0001). CONCLUSIONS ECL assays improved the ability to predict time to diabetes in these autoantibody-positive relatives at risk for developing diabetes. These findings might be helpful in the design and eligibility criteria for prevention trials in the future. PMID:27456836

  19. Do Electrochemiluminescence Assays Improve Prediction of Time to Type 1 Diabetes in Autoantibody-Positive TrialNet Subjects?

    PubMed

    Fouts, Alexandra; Pyle, Laura; Yu, Liping; Miao, Dongmei; Michels, Aaron; Krischer, Jeffrey; Sosenko, Jay; Gottlieb, Peter; Steck, Andrea K

    2016-10-01

    To explore whether electrochemiluminescence (ECL) assays can help improve prediction of time to type 1 diabetes in the TrialNet autoantibody-positive population. TrialNet subjects who were positive for one or more autoantibodies (microinsulin autoantibody, GAD65 autoantibody [GADA], IA-2A, and ZnT8A) with available ECL-insulin autoantibody (IAA) and ECL-GADA data at their initial visit were analyzed; after a median follow-up of 24 months, 177 of these 1,287 subjects developed diabetes. Univariate analyses showed that autoantibodies by radioimmunoassays (RIAs), ECL-IAA, ECL-GADA, age, sex, number of positive autoantibodies, presence of HLA DR3/4-DQ8 genotype, HbA1c, and oral glucose tolerance test (OGTT) measurements were all significantly associated with progression to diabetes. Subjects who were ECL positive had a risk of progression to diabetes within 6 years of 58% compared with 5% for the ECL-negative subjects (P < 0.0001). Multivariate Cox proportional hazards models were compared, with the base model including age, sex, OGTT measurements, and number of positive autoantibodies by RIAs. The model with positivity for ECL-GADA and/or ECL-IAA was the best, and factors that remained significantly associated with time to diabetes were area under the curve (AUC) C-peptide, fasting C-peptide, AUC glucose, number of positive autoantibodies by RIAs, and ECL positivity. Adding ECL to the Diabetes Prevention Trial risk score (DPTRS) improved the receiver operating characteristic curves with AUC of 0.83 (P < 0.0001). ECL assays improved the ability to predict time to diabetes in these autoantibody-positive relatives at risk for developing diabetes. These findings might be helpful in the design and eligibility criteria for prevention trials in the future. © 2016 by the American Diabetes Association.

  20. Determination of clusters and factors associated with dengue dispersion during the first epidemic related to Dengue virus serotype 4 in Vitória, Brazil

    PubMed Central

    Herbinger, Karl-Heinz; Cerutti Junior, Crispim; Malta Romano, Camila; de Souza Areias Cabidelle, Aline; Fröschl, Günter

    2017-01-01

    Dengue occurrence is partially influenced by the immune status of the population. Consequently, the introduction of a new Dengue virus serotype can trigger explosive epidemics in susceptible populations. The determination of clusters in this scenario can help to identify hotspots and understand the disease dispersion regardless of the influence of the population herd immunity. The present study evaluated the pattern and factors associated with dengue dispersion during the first epidemic related to Dengue virus serotype 4 in Vitória, Espírito Santo state, Brazil. Data on 18,861 dengue cases reported in Vitória from September 2012 to June 2013 were included in the study. The analysis of spatial variation in temporal trend was performed to detect clusters that were compared by their respective relative risk, house index, population density, and income in an ecological study. Overall, 11 clusters were detected. The time trend increase of dengue incidence in the overall study population was 636%. The five clusters that showed a lower time trend increase than the overall population presented a higher incidence in the beginning of the epidemic and, compared to the six clusters with higher time trend increase, they presented higher relative risk for their inhabitants to acquire dengue infection (P-value = 0.02) and a lower income (P-value <0.01). House index and population density did not differ between the clusters. Early increase of dengue incidence and higher relative risk for acquiring dengue infection were favored in low-income areas. Preventive actions and improvement of infrastructure in low-income areas should be prioritized in order to diminish the magnitude of dengue dispersion after the introduction of a new serotype. PMID:28388694

  1. Social and behavior change communication in the fight against malaria in Mozambique.

    PubMed

    Arroz, Jorge Alexandre Harrison

    2017-03-23

    Long-lasting insecticide-treated nets and/or indoor residual spraying, associated with case management, are key interventions in the control of malaria in Africa. The objective of this study is to comment on the role of social and behavior change communication as a potential key intervention in the control of malaria in Mozambique. RESUMO As redes mosquiteiras impregnadas com insecticidade de longa duração e/ou pulverização intra-domiciliária, associada ao manejo de casos são intervenções-chave no controlo da malária em África. O objetivo deste estudo foi comentar o papel da comunicação para a mudança social e de comportamento como intervenção potencialmente chave no controlo da malária em Moçambique.

  2. The relationship of the Reynolds Intellectual Assessment Scales and the Wechsler Adult Intelligence Scale-Third Edition.

    PubMed

    Smith, Billy L; McChristian, Chrystal L; Smith, Teresa D; Meaux, Julie

    2009-08-01

    The purpose of this study was to compare scores on the Reynolds Intellectual Assessment Scales (RIAS) with scores on the Wechsler Adult Intelligence Scale-Third Edition (WAIS-III) in a group of college students diagnosed with a Learning Disability, Attention-Deficit Hyperactivity Disorder (ADHD), or a combination of the two. The RIAS Composite Index score was significantly higher than the WAIS-III Full Scale IQ, although scores on both tests were in the average range. Correlations between the two tests were significant on all measures. Male students were significantly higher than female students on both the RIAS Composite Index and on the WAIS-III Full Scale IQ. Although the ADHD group was higher on IQ than the Learning Disabled and combined disorder groups on all IQ measures, no significant differences were found.

  3. Variability of Hormonal Stress Markers Collected from a Managed Dolphin Population

    DTIC Science & Technology

    2014-09-30

    physiological indicators of stress in wild marine mammals and the interrelationships between different stress markers can be used to estimate the impact...and thyroid hormones via radioimmunoassay (RIA). The methods have been validated for cortisol and aldosterone in this species (Houser et al., 2011...measurement methods. Metabolites of cortisol, aldosterone and thyroid hormone will be extracted from fecal samples and measured via RIA using established

  4. The Feasibility and Usability of the Read It Again Dual Language and Literacy Curriculum

    ERIC Educational Resources Information Center

    Durán, Lillian K.; Gorman, Brenda K.; Kohlmeier, Theresa; Callard, Chase

    2016-01-01

    The purpose of this paper is to describe the components, usability, and feasibility of a new Read it Again-Dual Language curriculum (RIA-DL; Durán et al. n.d.). The RIA-DL is based on the Read it Again-PreK! (Justice and McGinty 2009) and adapted to meet the unique needs of Spanish-English bilingual preschoolers. The curriculum targets…

  5. Methodological aspects of rat beta-endorphin analysis-influence of diurnal variation.

    PubMed

    Finn, Anja; Fabre, Susanne Froelich; Hellström, Per M; Brené, Stefan

    2006-05-30

    Beta-endorphin radioimmunoassays (RIAs) are widely performed following physical, emotional and environmental challenges in the rat. In the literature, a wide range of techniques have been described, but in the present study, we have focused on methodological aspects of beta-endorphin RIAs, investigating various characteristics of human and rat specific antibodies. Initial studies verified that the RIA outcome was not appropriate when using non-species compatible components. Novel rat beta-endorphin antibodies, r 4114 and r 4268, were raised in rabbits and characterised in terms of specificity, avidity and titer. Both of the new antisera showed 68.1% cross-reactivity with human beta-endorphin. The ED50 was 50+/-8 pmol/l, and the mean ED80 was 17 pmol/l for r 4268 but three-fold higher for r 4114. The intra-assay coefficient of variation (CV) was 7% at 100 pmol/l and the inter-assay CV was 10% at the same level for r 4268 and similar for r 4114. Using this novel rat beta-endorphin RIA for analyses of diurnal influence and removal from the Animal House cage, no significant changes were observed in either the hypothalamus or peri-aqueductal grey regions. These results suggest that rat beta-endorphin concentrations in these brain areas are not affected by order of removal or diurnal variation.

  6. A kinetic model to explain the grain size and organic matter content dependence of magnetic susceptibility in transitional marine environments: A case study in Ria de Muros (NW Iberia)

    NASA Astrophysics Data System (ADS)

    Mohamed, Kais J.; Andrade, Alba; Rey, Daniel; Rubio, Belén.; Bernabeu, Ana María.

    2017-06-01

    Magnetic minerals in marine sediments are sensitive indicators of processes such as provenance changes, climatic controls, pollution, and postdepositional geochemical changes. Magnetic susceptibility is the bulk property of the sediments most commonly used to understand the magnetic characteristics of sediments. Before conclusions can be drawn from changes in this parameter, it is important to understand what factors and to what extent control changes in magnetic susceptibility. The magnetic susceptibility of surficial sediments in the Galician Rias Baixas, in NW Spain, has been shown to covary with sediment texture and organic matter content. Downcore, the magnetic properties of these sediments experience drastic changes as a result of strong dissolution caused by early diagenesis. In this paper, we further explore the relationship between these factors and formalize the observed covariations as the result of a simple second-order kinetic model dependent on the content of organic matter in surficial sediments in the Ria de Muros. The reanalysis of previously reported data from the Rias de Vigo and Pontevedra confirmed the validity of this model and suggested further controls such as wave climate and water depth in the rates at which magnetic susceptibility changes are controlled by organic matter content.

  7. Biomonitoring of urinary metals in a population living in the vicinity of industrial sources: a comparison with the general population of Andalusia, Spain.

    PubMed

    Aguilera, Inmaculada; Daponte, Antonio; Gil, Fernando; Hernández, Antonio F; Godoy, Patricia; Pla, Antonio; Ramos, Juan Luis

    2008-12-15

    The Ria of Huelva (south-west Spain) is one of the most polluted fluvial-estuarine systems in the world. Industrial activity delivers huge amounts of pollutants to the local environment, particularly heavy metals and arsenic. Here we aimed to determine urinary levels of As, Cd, Cr, Cu and Ni in a representative sample (n=857) of adults living in the Ria of Huelva. Levels were compared to those from a representative sample of 861 adults of the general urban population of Andalusia (southern Spain) and multiple regression models were developed to identify individual factors associated with urinary levels of these elements. Arsenic levels were significantly higher in the Ria of Huelva as compared to other Andalusian cities, whereas Cd and Ni levels were significantly lower. Despite these differences, levels in both groups were similar to the reference values reported in previous studies for general population. Age, gender, diet and lifestyle were the major factors contributing to the interindividual variation in urinary metals. In conclusion, despite living in a highly polluted area, the population of the Ria of Huelva failed to show higher urinary levels of the studied metals as compared to a reference urban population of the same region.

  8. A reliability study on brain activation during active and passive arm movements supported by an MRI-compatible robot.

    PubMed

    Estévez, Natalia; Yu, Ningbo; Brügger, Mike; Villiger, Michael; Hepp-Reymond, Marie-Claude; Riener, Robert; Kollias, Spyros

    2014-11-01

    In neurorehabilitation, longitudinal assessment of arm movement related brain function in patients with motor disability is challenging due to variability in task performance. MRI-compatible robots monitor and control task performance, yielding more reliable evaluation of brain function over time. The main goals of the present study were first to define the brain network activated while performing active and passive elbow movements with an MRI-compatible arm robot (MaRIA) in healthy subjects, and second to test the reproducibility of this activation over time. For the fMRI analysis two models were compared. In model 1 movement onset and duration were included, whereas in model 2 force and range of motion were added to the analysis. Reliability of brain activation was tested with several statistical approaches applied on individual and group activation maps and on summary statistics. The activated network included mainly the primary motor cortex, primary and secondary somatosensory cortex, superior and inferior parietal cortex, medial and lateral premotor regions, and subcortical structures. Reliability analyses revealed robust activation for active movements with both fMRI models and all the statistical methods used. Imposed passive movements also elicited mainly robust brain activation for individual and group activation maps, and reliability was improved by including additional force and range of motion using model 2. These findings demonstrate that the use of robotic devices, such as MaRIA, can be useful to reliably assess arm movement related brain activation in longitudinal studies and may contribute in studies evaluating therapies and brain plasticity following injury in the nervous system.

  9. [Dialogues between Clio and Asclepius: Ivolino de Vasconcellos and the Revista Brasileira de História da Medicina].

    PubMed

    Amoroso, Mauro

    2007-01-01

    The Brazilian Institute for the History of Medicine was founded on 1945 by the physician Ivolino de Vasconcellos. Because the movement intended to be of national scope, the Federação Nacional de História da Medicina e Ciências Afins was also created (National Federation for the History of Medicine and Related Sciences). The latter group had a humanistic understanding of medicine, wherein the history of medicine played a central role; since this subject honored great names and achievements in medicine, members of the federation felt it was a prime tool in the ethical and humanistic training of healthcare professionals. Thus was born the Revista Brasileira de História da Medicina, which fostered scientific and academic production and events in the field of history of medicine and also registered the Federation's activities and scientific output.

  10. Track-train dynamic analysis and test program, truck static test

    NASA Technical Reports Server (NTRS)

    Nemes, A. G.

    1974-01-01

    A series of tests were conducted to define the characteristics of an ASF 11 Ride Truck Assembly including joint slop, friction and stiffness. Loading to the truck assembly included vertical load to simulate the car/pool loading combined with lateral or moment loading that resulted in desired truck deflections for the various phases of testing. All seven test conditions were successfully completed with load and deflection data being collected. No attempt is made to reduce the applicable data other than to provide computer plots.

  11. Radio frequency power load and associated method

    NASA Technical Reports Server (NTRS)

    Sims, III, William Herbert (Inventor); Chavers, Donald Gregory (Inventor); Richeson, James J. (Inventor)

    2010-01-01

    A radio frequency power load and associated method. A radio frequency power load apparatus includes a container and a fluid having an ion source therein, the fluid being contained in the container. Two conductors are immersed in the fluid. A radio frequency transmission system includes a radio frequency transmitter, a radio frequency amplifier connected to the transmitter and a radio frequency power load apparatus connected to the amplifier. The apparatus includes a fluid having an ion source therein, and two conductors immersed in the fluid. A method of dissipating power generated by a radio frequency transmission system includes the steps of: immersing two conductors of a radio frequency power load apparatus in a fluid having an ion source therein; and connecting the apparatus to an amplifier of the transmission system.

  12. Optimal load scheduling in commercial and residential microgrids

    NASA Astrophysics Data System (ADS)

    Ganji Tanha, Mohammad Mahdi

    Residential and commercial electricity customers use more than two third of the total energy consumed in the United States, representing a significant resource of demand response. Price-based demand response, which is in response to changes in electricity prices, represents the adjustments in load through optimal load scheduling (OLS). In this study, an efficient model for OLS is developed for residential and commercial microgrids which include aggregated loads in single-units and communal loads. Single unit loads which include fixed, adjustable and shiftable loads are controllable by the unit occupants. Communal loads which include pool pumps, elevators and central heating/cooling systems are shared among the units. In order to optimally schedule residential and commercial loads, a community-based optimal load scheduling (CBOLS) is proposed in this thesis. The CBOLS schedule considers hourly market prices, occupants' comfort level, and microgrid operation constraints. The CBOLS' objective in residential and commercial microgrids is the constrained minimization of the total cost of supplying the aggregator load, defined as the microgrid load minus the microgrid generation. This problem is represented by a large-scale mixed-integer optimization for supplying single-unit and communal loads. The Lagrangian relaxation methodology is used to relax the linking communal load constraint and decompose the independent single-unit functions into subproblems which can be solved in parallel. The optimal solution is acceptable if the aggregator load limit and the duality gap are within the bounds. If any of the proposed criteria is not satisfied, the Lagrangian multiplier will be updated and a new optimal load schedule will be regenerated until both constraints are satisfied. The proposed method is applied to several case studies and the results are presented for the Galvin Center load on the 16th floor of the IIT Tower in Chicago.

  13. Magnetic resonance enterography changes after antibody to tumor necrosis factor (anti-TNF) alpha therapy in Crohn's disease: correlation with SES-CD and clinical-biological markers.

    PubMed

    Stoppino, Luca Pio; Della Valle, Nicola; Rizzi, Stefania; Cleopazzo, Elsa; Centola, Annarita; Iamele, Donatello; Bristogiannis, Christos; Stoppino, Giuseppe; Vinci, Roberta; Macarini, Luca

    2016-05-05

    In recent years, the use of MRI in patients with Crohn's disease (CD) has increased. However, few data are available on how MRI parameters of active disease change during treatment with anti-TNF and whether these changes correspond to symptoms, serum biomarkers, or endoscopic appearance. The aim of this study was to determine the changes over time in MRI parameters during treatment with anti-TNF in patients with CD, and to verify the correlation between MRI score, endoscopic appearance and clinical-biological markers. We performed a prospective single centre study of 27 patients with active CD (18 males and 9 females; median age of 27,4 ys; age range, 19-49). All patients underwent ileocolonoscopy and MRI at baseline and 26 weeks after anti-TNF therapy. Endoscopic severity was graded according to the Simple Endoscopic Score for Crohn's Disease (SES-CD) and Magnetic Resonance Index of Activity (MaRIA) was calculated. Patients underwent clinical evaluation (CDAI) and the C-reactive protein (CRP) level was measured. The associations between variables were assessed with Pearson's bivariate correlation analysis. A total of 135 intestinal segments were studied. The median patient age was 27,4 years, 67 % were male and the mean disease duration was 6,1 years. For induction of remission, 18 patients were treated with infliximab and 9 with adalimumab. The mean SES-CD and MaRIA scores significantly changed at week 26 (SES-CD: 14,7 ± 8,9 at baseline vs. 4,4 ± 4,6 at 26 weeks - p < 0.001; MaRIA: 41,1 ± 14,8 at baseline vs. 32,8 ± 11,7 at 26 weeks - p < 0.001). Also the CDAI and serum levels of CRP decreased significantly following treatment (p < 0.001). The overall MaRIA correlated with endoscopic score and with clinical activity (CDAI) both at baseline and at week 26 (p < 0.05). The correlation between overall MaRIA and CRP was significant only at week 26 (p < 0.001). The MaRIA has a good correlation with SES-CD, a high accuracy for prediction of endoscopic mucosal healing and is a reliable indicator to monitor the use of TNF antagonists in patients with CD.

  14. MASTICATORY FUNCTION OF OBESE CANDIDATES TO BARIATRIC SURGERY FROM DISTINCT SOCIOECONOMIC CLASSES.

    PubMed

    Passeri, Celso Roberto; Andrade, Jacira Alves Caracik de Camargo; Tomal, Karla Thaíza; Pracucho, Eduardo Marcucci; Campos, Livia Paschoalino de; Sales-Peres, Silvia Helena de Carvalho

    Obesity and metabolic syndrome can be labeled as worldwide outbreak; thus, both have led to serious public health problem. Oral health can be worsened by both, obesity and metabolic syndrome. Tooth loss harms masticatory function, essential status to whom will be submitted to bariatric surgery. Assess masticatory function of obese candidates to bariatric surgery, who belong to distinct socioeconomic class range, in order to recognize hazard factors and the bias of socioeconomic factor in this context. Observational cross-section study, with samples comprised by two groups of patients, with distinct socioeconomic class range, one of them belonging to public health system (SUSG) and the other to private clinic (CPG), candidates to bariatric surgery. Were assessed anthropometric data, comorbidities and medicines usage, blood tests, habits and the number of dental functional units. The groups SUSG and CPG were homogeneous taking into account gender (p=0,890) and age range (p=0,170). The number of dental functional units was higher in the private group (p<0.001). The impaired masticatory function was rather present among public group (p<0.001) and female gender (p<0,001). Regarded as blood tests, fasting glucose was higher in female in SUSG (p<0,001). The following hazard factors have corroborated to have patients rated as impaired masticatory function: belong to public service (OR: 8.420, p=0.003), higher age (OR: 1.186, p<0.001), female gender (OR: 0.153, p=0.029), diabetes mellitus (OR: 2.545, p=0.045) and smokers (OR: 2.951, p=0.043). The general health and masticatory function of female SUSG were worse, highlighting the socioeconomic condition as hazard factor. Obesidade e síndrome metabólica são graves problemas de saúde pública, com características de epidemia mundial. A saúde bucal é agravada por ambas as condições. Perda dentária prejudica função mastigatória, condição essencial para o paciente que será submetido à cirurgia bariátrica. Avaliar a função mastigatória de pacientes obesos candidatos à cirurgia bariátrica pertencentes a dois serviços de saúde com padrões socioeconômicos distintos, afim de identificar fatores de risco e a influência do fator socioeconômico nesta condição. Estudo observacional transversal, com amostra constituída por dois grupos de pacientes obesos, com condições socioeconômicas distintas, um pertencente ao sistema público de saúde (GSUS) e outro à clínica privada (GCP), candidatos à cirurgia bariátrica. Foram analisados dados antropométricos, comorbidades e uso de medicamentos para seu controle, exames laboratoriais, hábitos e o número de unidades funcionais dentárias presentes. Os grupos GSUS e GCP foram homogêneos quanto ao gênero (p=0,890) e faixa etária (p=0,170). A média de unidades funcionais dentárias foi maior no grupo privado (p<0,001). A função mastigatória prejudicada foi mais presente no grupo GSUS e no gênero feminino (p<0,001). Quanto aos exames laboratoriais: glicemia de jejum esteve mais alterada em mulheres do GSUS (p<0,001). Foram fatores de risco independentes para ter função mastigatória prejudicada: ter origem no serviço público de saúde (OR: 8,420 - p=0,003), maior idade (OR: 1,186 - p<0,001), ser do gênero feminino (OR: 0,153 - p=0,029), portador de diabete melito (OR: 2,545 - p=0,045) e tabagista (OR: 2,951 - p=0,043). A saúde geral e função mastigatória de mulheres do GSUS foram piores, ressaltando a condição socioeconômica como fator de risco.

  15. Wirelessly controlled micro- and nanostructures for bioapplications

    NASA Astrophysics Data System (ADS)

    Lindo, Andre Machado

    Apresentar uma contribuicao para a caracterizacao e compreensao do comportamento hidrodinâmico da laguna Ria de Aveiro, baseada num estudo experimental e num estudo de modelacao numerica, e o objectivo deste trabalho. As caracteristicas hidrologicas da Ria de Aveiro foram investigadas atraves da realizacao de varias campanhas de amostragem, tendo sido efectuadas medicoes de altura de agua, salinidade, temperatura da agua e velocidade da corrente em varias estacoes distribuidas ao longo de quatro canais principais da laguna. None

  16. Evaluation of the technical performance of novel holotranscobalamin (holoTC) assays in a multicenter European demonstration project.

    PubMed

    Morkbak, Anne L; Heimdal, Randi M; Emmens, Kathleen; Molloy, Anne; Hvas, Anne-Mette; Schneede, Joern; Clarke, Robert; Scott, John M; Ueland, Per M; Nexo, Ebba

    2005-01-01

    A commercially available holotranscobalamin (holo-TC) radioimmunoassay (RIA) (Axis-Shield, Dundee, Scotland) was evaluated in four laboratories and compared with a holoTC ELISA run in one laboratory. The performance of the holoTC RIA assay was comparable in three of the four participating laboratories. The results from these three laboratories, involving at least 20 initial runs of "low", "medium" and "high" serum-based controls (mean holoTC concentrations 34, 60 and 110 pmol/L, respectively) yielded an intra-laboratory imprecision of 6-10%. No systematic inter-laboratory deviations were observed on runs involving 72 patient samples (holoTC concentration range 10-160 pmol/L). A fourth laboratory demonstrated higher assay imprecision for control samples and systematic deviation of results for the patient samples. Measurement of holoTC by ELISA showed an imprecision of 4-5%, and slightly higher mean values for the controls (mean holoTC concentrations 40, 70 and 114 pmol/L, respectively). Comparable results were obtained for the patient samples. The long-term intra-laboratory imprecision was 12% for the holoTC RIA and 6% for the ELISA. In conclusion, it would be prudent to check the calibration and precision prior to starting to use these holoTC assays in research or clinical practice. The results obtained using the holoTC RIA were similar to those obtained using the holoTC ELISA assay.

  17. Unified Aeroacoustics Analysis for High Speed Turboprop Aerodynamics and Noise. Volume 1; Development of Theory for Blade Loading, Wakes, and Noise

    NASA Technical Reports Server (NTRS)

    Hanson, D. B.

    1991-01-01

    A unified theory for the aerodynamics and noise of advanced turboprops are presented. Aerodynamic topics include calculation of performance, blade load distribution, and non-uniform wake flow fields. Blade loading can be steady or unsteady due to fixed distortion, counter-rotating wakes, or blade vibration. The aerodynamic theory is based on the pressure potential method and is therefore basically linear. However, nonlinear effects associated with finite axial induction and blade vortex flow are included via approximate methods. Acoustic topics include radiation of noise caused by blade thickness, steady loading (including vortex lift), and unsteady loading. Shielding of the fuselage by its boundary layer and the wing are treated in separate analyses that are compatible but not integrated with the aeroacoustic theory for rotating blades.

  18. Pneumatic load compensating or controlling system

    NASA Technical Reports Server (NTRS)

    Rogers, J. R. (Inventor)

    1975-01-01

    A pneumatic load compensating or controlling system for restraining a load with a predetermined force or applying a predetermined force to the load is described; it includes a source of pressurized air, a one-way pneumatic actuator operatively connected to a load, and a fluid conduit fluidically connecting the actuator with the source of pressurized air. The actuator is of the piston and cylinder type, and the end of the fluid conduit is connected to the upper or lower portion of the cylinder whereby the actuator alternatively and selectively restrains the load with a predetermined force or apply a predetermined force to the load. Pressure regulators are included within the system for variably selectively adjusting the pressurized fluid to predetermined values as desired or required; a pressure amplifier is included within the system for multiplying the pressurized values so as to achieve greater load forces. An accumulator is incorporated within the system as a failsafe operating mechanism, and visual and aural alarm devices, operatively associated with pressure detecting apparatus, readily indicate the proper or improper functioning of the system.

  19. Development of iFab (Instant Foundry Adaptive Through Bits) Manufacturing Process and Machine Library

    DTIC Science & Technology

    2012-08-01

    loaded joints including bearing -type shear loaded joints and friction type shear loaded joints . Appendix Figure 2f.A-3 shows an illustration of each... Loaded Joint Bearing Type Shear Loaded Joint Friction Type Shear Loaded Joint Tension Loaded Joint 62 Approved for public release...Joining of materials and structures: from pragmatic process to enabling technology.

  20. Load power device, system and method of load control and management employing load identification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Yi; Luebke, Charles John; Schoepf, Thomas J.

    A load power device includes a power input, at least one power output for at least one load, a plurality of sensors structured to sense voltage and current at the at least one power output, and a processor. The processor provides: (a) load identification based upon the sensed voltage and current, and (b) load control and management based upon the load identification.

  1. Violence against women, Espírito Santo, Brazil.

    PubMed

    Leite, Franciele Marabotti Costa; Amorim, Maria Helena Costa; Wehrmeister, Fernando C; Gigante, Denise Petrucci

    2017-04-10

    To estimate the prevalence and factors associated with psychological, physical and sexual violence in women victims of intimate partner violence assisted in the primary care services. This is a cross-sectional study, conducted in 26 health units in Vitória, State of Espírito Santo, from March to September 2014. We interviewed 991 women aged 20-59 years. To classify the psychological, physical and sexual violence, the World Health Organization instrument on violence against women was used and a questionnaire to investigate the sociodemographic, behavioral characteristics, and the women's family and life history was developed. The statistical analyzes used were Poisson regression, Fisher's exact test and Chi-square. The prevalence we observed were psychological 25.3% (95%CI 22.6-28.2); physical 9.9% (95%CI 8.1-11.9) and sexual 5.7% (95%CI 4.3-7.3). Psychological violence remained associated with education, marital status, maternal history of intimate partner violence, sexual violence in childhood and drug use, while physical assault was related to age, education, marital status and maternal history of intimate partner violence. Sexual violence occurred the most among women with low income, and victims of sexual violence in childhood. Psychological, physical and sexual violence showed highly frequency among women assisted by primary care services. Sociodemographic and behavioral factors, personal experiences, and maternal violence influence the phenomenon. Estimar a prevalência e os fatores associados às violências psicológica, física e sexual nas mulheres vítimas de violência perpetrada pelo parceiro íntimo atendidas nos serviços de atenção primária. Estudo transversal, realizado em 26 unidades de saúde do município de Vitória, no Espírito Santo, de março a setembro de 2014. Foram entrevistadas 991 usuárias de 20 a 59 anos. Para classificar as violências psicológica, física e sexual foi utilizado o instrumento da Organização Mundial de Saúde sobre violência contra a mulher e um questionário foi elaborado para investigar as características sociodemográficas, comportamentais e de história familiar e de vida da mulher. As análises estatísticas utilizadas foram: regressão de Poisson, teste exato de Fisher e Qui-quadrado. As prevalências observadas foram: psicológica 25,3% (IC95% 22,6-28,2); física 9,9% (IC95% 8,1-11,9) e sexual 5,7% (IC95% 4,3-7,3). A violência psicológica manteve-se associada à escolaridade, situação conjugal, histórico materno de violência por parceiro íntimo, violência sexual na infância e ter feito uso de drogas, enquanto a agressão física esteve relacionada à idade, escolaridade, situação conjugal e a história materna de violência por parceiro íntimo. A violência sexual foi mais frequente nas mulheres de menor renda e que sofreram abuso sexual na infância. As violências psicológica, física e sexual apresentaram alta magnitude entre as mulheres usuárias dos serviços de atenção primária de saúde. Fatores sociodemográficos, comportamentais e experiências pessoal e materna de violência influenciam a ocorrência do fenômeno.

  2. Anti-dsDNA antibodies in systemic lupus erythematosus: A combination of two quantitative methods and the ANA pattern is the most efficient strategy of detection.

    PubMed

    Almeida González, Delia; Roces Varela, Alfredo; Marcelino Rodríguez, Itahisa; González Vera, Alexander; Delgado Sánchez, Mónica; Aznar Esquivel, Antonio; Casañas Rodríguez, Carlos; Cabrera de León, Antonio

    2015-12-01

    Several methods have been used to measure anti-double-stranded DNA auto-antibody (anti-dsDNA). Our aim was to determine the most efficient strategy to test anti-dsDNA in systemic lupus erythematosus (SLE). In this study, anti-dsDNA and anti-nuclear antibody (ANA) tests were requested for 644 patients. Anti-dsDNA was tested by RIA, ELISA and CLIA in all patients. The results indicated that 78 patients had a positive anti-dsDNA test according to at least one of the methods. After a 3-year follow-up period only 26 patients were diagnosed with SLE. We evaluated each method and combination of methods. Specificity and positive predictive value (PPV) increased with the number of assay methods used (p=0.002 for trend), and PPV was 100% in patients whose results were positive by all three anti-dsDNA assay methods. The proportion of anti-dsDNA-positive patients who had SLE was highest (82%; p b 0.001) among those with a homogeneous pattern of ANA staining, followed by those with a speckled pattern. In ANA positive patients, when only RIA was considered, 59% of anti-dsDNA-positive patients had SLE, but when RIA and CLIA were both considered, all patients with positive results on both tests had SLE. The combination of RIA+CLIA in patients with homogeneous and speckled ANA staining showed a similar cost and higher sensitivity than RIA alone in ANA positive patients (p b 0.001). We conclude that the most efficient strategy was to combine simultaneously two quantitative and sensitive methods but only in patients with a homogeneous or speckled pattern of ANA staining. This approach maximized specificity and PPV, and reduced costs. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Gender, exercise training, and eNOS expression in porcine skeletal muscle arteries.

    PubMed

    Laughlin, M Harold; Welshons, Wade V; Sturek, Michael; Rush, James W E; Turk, James R; Taylor, Julia A; Judy, Barbara M; Henderson, Kyle K; Ganjam, V K

    2003-07-01

    Our purpose was to determine the effects of gender and exercise training on endothelial nitric oxide synthase (eNOS) and superoxide dismutase (SOD) protein content of porcine skeletal muscle arteries and to evaluate the role of 17beta-estradiol (E2) in these effects. We measured eNOS and SOD content with immunoblots and immunohistochemistry in femoral and brachial arteries of trained and sedentary male and female pigs and measured estrogen receptor (ER) mRNA and alpha-ER and beta-ER protein in aortas of male and female pigs. Results indicate that female arteries contain more eNOS than male arteries and that exercise training increases eNOS content independent of gender. Male and female pigs expressed similar levels of alpha-ER mRNA and protein and similar amounts beta-ER protein in their arteries. E2 concentrations as measured by RIA were 180 +/- 34 pg/ml in male sera and approximately 5 pg/ml in female sera, and neither was changed by training. However, bioassay indicated that biologically active estrogen equivalent to only 35 +/- 5 pg/ml was present in male sera. E2 in female pigs, whether measured by RIA or bioassay, was approximately 24 pg/ml at peak estrous and 2 pg/ml on day 5 diestrus. The free fraction of E2 in sera did not explain the low measurements, relative to RIA, of E2. We conclude that 1). gender has significant influence on eNOS and SOD content of porcine skeletal muscle arteries; 2). the effects of gender and exercise training vary among arteries of different anatomic origin; 3). male sera contains compounds that cause RIA to overestimate circulating estrogenic activity; and 4). relative to human men, the male pig is not biologically estrogenized by high levels of E2 reported by RIA, whereas in female pigs E2 levels are lower than in the blood of human women.

  4. Student-centered tutoring as a model for patient-centeredness and empathy.

    PubMed

    Meirovich, Adaya; Ber, Rosalie; Moore, Michael; Rotschild, Avi

    2016-01-01

    Curriculum planners and medical teachers attempt to enhance medical students' empathy and patient-centeredness. Despite educational efforts, there is stability in medical students' empathy and patient-centered medicine during the preclinical stage and a decline in both of them throughout the clinical years. Student-tutor relationship plays a key role in students' learning. This study tests the effect of learner-centered tutoring on students' empathy, patient-centeredness, and behavior. The cohort of 55 students was divided into groups of seven or eight. The experimental group's tutors underwent LC mentoring. Empathy was assessed with the Jefferson Scale of Physician Empathy for Students; PC attitude was assessed with the Patient-Provider Orientation Scale (PPOS). Behavior was assessed by simulations of doctor-patient encounters with 32 students at the end of the third year. Each student participated in three such simulations, during which we analyzed ten aspects of physician-patient communication via Roter interaction analysis system (RIAS)-coded audiotapes. A significant group difference was found for three RIAS categories: building a relationship and patient-centeredness, where the mean percentage of the experimental group was significantly higher than that of the control group, and gathering data, where the mean percentage of the experimental group was significantly lower than that of the control group. A significant correlation was found in the experimental group between empathy and positive talk and between PPOS and three of the RIAS categories: gathering data, psychosocial talk, and patient-centeredness. A significant negative correlation was found in the experimental group between PPOS and two of the RIAS categories: negative talk and doctor-centeredness. Two significant negative correlations were found in the control group: between empathy and patient-centeredness and PPOS and negative talk. The LC approach supports two of the RIAS categories, corresponding to clinical empathy and PC care and the link between certain behaviors and the PPOS.

  5. The Retrospective Iterated Analysis Scheme for Nonlinear Chaotic Dynamics

    NASA Technical Reports Server (NTRS)

    Todling, Ricardo

    2002-01-01

    Atmospheric data assimilation is the name scientists give to the techniques of blending atmospheric observations with atmospheric model results to obtain an accurate idea of what the atmosphere looks like at any given time. Because two pieces of information are used, observations and model results, the outcomes of data assimilation procedure should be better than what one would get by using one of these two pieces of information alone. There is a number of different mathematical techniques that fall under the data assimilation jargon. In theory most these techniques accomplish about the same thing. In practice, however, slight differences in the approaches amount to faster algorithms in some cases, more economical algorithms in other cases, and even give better overall results in yet some other cases because of practical uncertainties not accounted for by theory. Therefore, the key is to find the most adequate data assimilation procedure for the problem in hand. In our Data Assimilation group we have been doing extensive research to try and find just such data assimilation procedure. One promising possibility is what we call retrospective iterated analysis (RIA) scheme. This procedure has recently been implemented and studied in the context of a very large data assimilation system built to help predict and study weather and climate. Although the results from that study suggest that the RIA scheme produces quite reasonable results, a complete evaluation of the scheme is very difficult due to the complexity of that problem. The present work steps back a little bit and studies the behavior of the RIA scheme in the context of a small problem. The problem is small enough to allow full assessment of the quality of the RIA scheme, but it still has some of the complexity found in nature, namely, its chaotic-type behavior. We find that the RIA performs very well for this small but still complex problem which is a result that seconds the results of our early studies.

  6. Highly sensitive radioimmunoassay for chorionic gonadotropin in human urine. [/sup 125/I tracer technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ayala, A.R.; Nisula, B.C.; Chen, H.C.

    1978-10-01

    The value of RIAs that measure hCG levels in human urine has been limited principally because of cross-reactivity with human LH. Recently, antisera generated to antigenic determinants on the intact hCG..beta.. subunit and its carboxyl-terminal peptide have been shown to exhibit substantially reduced human LH cross-reactivity. To take maximal advantage of these antisera and to minimize interference by nonspecific substances in urine, a procedure for extracting and concentrating hCG from 24-h urine samples was developed. The procedure involves preparation of a standard kaolin-acetone urine concentrate and adsorption of the hCG in the concentrate to Concanavalin A covalently linked to agarosemore » for purification and subsequent RIA. In urine samples obtained from patients with gestational trophoblastic disease, there was a direct correlation between hCG levels measured by RIA and those estimated by mouse uterine weight bioassy. In individual subjects, hCG levels were determined in serum and urine obtained the same day. When hCG was clearly detectable in the serum at levels greater than 1 ng/ml, the quantity of hCG measured in the urine concentrate exceeded 500 ng/24 h. The concentrates prepared from the urine of normal persons contained an hCG-like glycoprotein substance with antigenic determinants similar to those of the carboxyl-terminal peptide of hCG..beta... As the range of hCG immunoreactivity measured in the urine concentrates of normal subjects was 6 to 52 ng/24 h, specific and sensitive detection of urinary hCG could be accomplished in patients whose sera contained hCG undetectable by conventional RIA. Partial purification and concentration of urinary hCG by this procedure with subsequent RIA provides a sensitive and reliable method for detecting hCG in urine.« less

  7. Student-centered tutoring as a model for patient-centeredness and empathy

    PubMed Central

    Meirovich, Adaya; Ber, Rosalie; Moore, Michael; Rotschild, Avi

    2016-01-01

    Background Curriculum planners and medical teachers attempt to enhance medical students’ empathy and patient-centeredness. Despite educational efforts, there is stability in medical students’ empathy and patient-centered medicine during the preclinical stage and a decline in both of them throughout the clinical years. Student–tutor relationship plays a key role in students’ learning. This study tests the effect of learner-centered tutoring on students’ empathy, patient-centeredness, and behavior. Participants and methods The cohort of 55 students was divided into groups of seven or eight. The experimental group’s tutors underwent LC mentoring. Empathy was assessed with the Jefferson Scale of Physician Empathy for Students; PC attitude was assessed with the Patient–Provider Orientation Scale (PPOS). Behavior was assessed by simulations of doctor–patient encounters with 32 students at the end of the third year. Each student participated in three such simulations, during which we analyzed ten aspects of physician–patient communication via Roter interaction analysis system (RIAS)-coded audiotapes. Results A significant group difference was found for three RIAS categories: building a relationship and patient-centeredness, where the mean percentage of the experimental group was significantly higher than that of the control group, and gathering data, where the mean percentage of the experimental group was significantly lower than that of the control group. A significant correlation was found in the experimental group between empathy and positive talk and between PPOS and three of the RIAS categories: gathering data, psychosocial talk, and patient-centeredness. A significant negative correlation was found in the experimental group between PPOS and two of the RIAS categories: negative talk and doctor–centeredness. Two significant negative correlations were found in the control group: between empathy and patient-centeredness and PPOS and negative talk. Conclusion The LC approach supports two of the RIAS categories, corresponding to clinical empathy and PC care and the link between certain behaviors and the PPOS. PMID:27555803

  8. Transistor-based filter for inhibiting load noise from entering a power supply

    DOEpatents

    Taubman, Matthew S

    2013-07-02

    A transistor-based filter for inhibiting load noise from entering a power supply is disclosed. The filter includes a first transistor having an emitter coupled to a power supply, a collector coupled to a load, and a base. The filter also includes a first capacitor coupled between the base of the first transistor and a ground terminal. The filter further includes an impedance coupled between the base and a node between the collector and the load, or a second transistor and second capacitor. The impedance can be a resistor or an inductor.

  9. Transistor-based filter for inhibiting load noise from entering a power supply

    DOEpatents

    Taubman, Matthew S

    2015-02-24

    A transistor-based filter for inhibiting load noise from entering a power supply is disclosed. The filter includes a first transistor having an emitter coupled to a power supply, a collector coupled to a load, and a base. The filter also includes a first capacitor coupled between the base of the first transistor and a ground terminal The filter further includes an impedance coupled between the base and a node between the collector and the load, or a second transistor and second capacitor. The impedance can be a resistor or an inductor.

  10. Occurrence and sources of selected phenolic endocrine disruptors in Ria de Aveiro, Portugal

    PubMed Central

    Sousa, Ana; Galante-Oliveira, Susana; Barroso, Carlos M.; Kohler, Hans-Peter E.; Giger, Walter

    2009-01-01

    Background, aim and scope Ria de Aveiro (Portugal) is a shallow coastal lagoon of high economic and ecological importance. Hardly any data on its chemical pollution by polar organic pollutants are available in literature. This study focused on the presence and sources of a series of phenolic endocrine-disrupting compounds (EDCs) in this area, including parabens, alkylphenolic compounds and bisphenol-A (BPA). A number of possible sources of pollution are present in the area, including the large harbours present in the lagoon, the city of Aveiro and the rivers discharging into the area. A recently constructed submarine wastewater outfall, located a few kilometres from the lagoon inlet has also been suggested as a possible source of pollution to Ria de Aveiro in several publications. The aim of the current field study was to investigate the occurrence and main sources of phenolic endocrine disruptors in Ria de Aveiro. Materials and methods An extensive sampling campaign was performed, with surface water and wastewater grab samples taken at over 50 locations, in duplicate on different days. Samples were treated using solid phase extraction and analysed by liquid chromatography tandem mass spectrometry. Results and discussion Concentrations in lagoon water were generally low: not exceeding 20 ng/L for most analytes. Levels in river water exceeded those in the lagoon by a factor 3 to 500 (o-phenylphenol (PhP) and nonylphenoxy ethoxy acetic acids (A9PEC), respectively), with concentrations up to 700 ng/L for BPA and 7,300 ng/L for A9PEC. Samples from the harbours showed EDC levels similar to those in the rest of the lagoon, but in the city of Aveiro, elevated concentrations were observed for alkylphenol ethoxylates (A9PEO), A9PEC, PhP and BPA. Wastewater effluents showed low levels for parabens, whilst alkylphenolic compounds reached several micrograms per litre. The effluents are discharged into the ocean via a submarine outfall, but as marine water near the outfall showed slightly elevated concentrations only for A9PEO, it does not seem to be a significant source of these EDCs for the area. Conclusions All the studied phenolic EDCs were detected in the study area, with high levels found in some of the rivers discharging into the lagoon, and generally low concentrations in the lagoon itself. The main sources for all investigated EDCs were the rivers Caster and Antuã which discharge into the lagoon. The city of Aveiro was identified as a secondary source. As the tidal water exchange volume is much larger than the freshwater input from the rivers, concentrations of phenolic EDCs remained low in the lagoon. Electronic supplementary material The online version of this article (doi:10.1007/s11356-009-0275-5) contains supplementary material, which is available to authorized users. PMID:20017000

  11. Load research manual. Volume 3: Load research for advanced technologies

    NASA Astrophysics Data System (ADS)

    1980-11-01

    Technical guidelines for electric utility load research are presented. Special attention is given to issues raised by the load reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. The manual includes guides to load research literature and glossaries of load research and statistical terms. Special load research procedures are presented for solar, wind, and cogeneration technologies.

  12. Radio Frequency Power Load and Associated Method

    NASA Technical Reports Server (NTRS)

    Srinivasan, V. Karthik (Inventor); Freestone, Todd M. (Inventor); Sims, William Herbert, III (Inventor)

    2014-01-01

    A radio frequency power load and associated method. A radio frequency power load apparatus may include a container with an ionized fluid therein. The apparatus may include one conductor immersed in a fluid and another conductor electrically connected to the container. A radio frequency transmission system may include a radio frequency transmitter, a radio frequency amplifier connected to the transmitter and a radio frequency power load apparatus connected to the amplifier. The apparatus may include a fluid having an ion source therein, one conductor immersed in a fluid, and another conductor electrically connected to the container. A method of dissipating power generated by a radio frequency transmission system may include constructing a waveguide with ionized fluid in a container and connecting the waveguide to an amplifier of the transmission system.

  13. Reliability Constrained Priority Load Shedding for Aerospace Power System Automation

    NASA Technical Reports Server (NTRS)

    Momoh, James A.; Zhu, Jizhong; Kaddah, Sahar S.; Dolce, James L. (Technical Monitor)

    2000-01-01

    The need for improving load shedding on board the space station is one of the goals of aerospace power system automation. To accelerate the optimum load-shedding functions, several constraints must be involved. These constraints include congestion margin determined by weighted probability contingency, component/system reliability index, generation rescheduling. The impact of different faults and indices for computing reliability were defined before optimization. The optimum load schedule is done based on priority, value and location of loads. An optimization strategy capable of handling discrete decision making, such as Everett optimization, is proposed. We extended Everett method to handle expected congestion margin and reliability index as constraints. To make it effective for real time load dispatch process, a rule-based scheme is presented in the optimization method. It assists in selecting which feeder load to be shed, the location of the load, the value, priority of the load and cost benefit analysis of the load profile is included in the scheme. The scheme is tested using a benchmark NASA system consisting of generators, loads and network.

  14. Determination of mean camber surfaces for wings having uniform chordwise loading and arbitrary spanwise loading in subsonic flow

    NASA Technical Reports Server (NTRS)

    Katzoff, S; Faison, M Frances; Dubose, Hugh C

    1954-01-01

    The field of a uniformly loaded wing in subsonic flow is discussed in terms of the acceleration potential. It is shown that, for the design of such wings, the slope of the mean camber surface at any point can be determined by a line integration around the wing boundary. By an additional line integration around the wing boundary, this method is extended to include the case where the local section lift coefficient varies with spanwise location (the chordwise loading at every section still remaining uniform). For the uniformly loaded wing of polygonal plan form, the integrations necessary to determine the local slope of the surface and the further integration of the slopes to determine the ordinate can be done analytically. An outline of these integrations and the resulting formulas are included. Calculated results are given for a sweptback wing with uniform chordwise loading and a highly tapered spanwise loading, a uniformly loaded delta wing, a uniformly loaded sweptback wing, and the same sweptback wing with uniform chordwise loading but elliptical span load distribution.

  15. National Launch System cycle 1 loads and models data book

    NASA Technical Reports Server (NTRS)

    Bugg, F.; Brunty, J.; Ernsberger, G.; Mcghee, D.; Gagliano, L.; Harrington, F.; Meyer, D.; Blades, E.

    1992-01-01

    This document contains preliminary cycle 1 loads for the National Launch System (NLS) 1 and 2 vehicles. The loads provided and recommended as design loads represent the maximum load expected during prelaunch and flight regimes, i.e., limit loads, except that propellant tank ullage pressure has not been included. Ullage pressure should be added to the loads book values for cases where the addition results in higher loads. The loads must be multiplied by the appropriate factors of safety to determine the ultimate loads for which the structure must be capable.

  16. A Comprehensive Evaluation of Steroid Metabolism in Women with Intrahepatic Cholestasis of Pregnancy

    PubMed Central

    Pařízek, Antonín; Hill, Martin; Dušková, Michaela; Vítek, Libor; Velíková, Marta; Kancheva, Radmila; Šimják, Patrik; Koucký, Michal; Kokrdová, Zuzana; Adamcová, Karolína; Černý, Andrej; Hájek, Zdeněk; Stárka, Luboslav

    2016-01-01

    Intrahepatic cholestasis of pregnancy (ICP) is a common liver disorder, mostly occurring in the third trimester. ICP is defined as an elevation of serum bile acids, typically accompanied by pruritus and elevated activities of liver aminotransferases. ICP is caused by impaired biliary lipid secretion, in which endogenous steroids may play a key role. Although ICP is benign for the pregnant woman, it may be harmful for the fetus. We evaluated the differences between maternal circulating steroids measured by RIA (17-hydroxypregnenolone and its sulfate, 17-hydroxyprogesterone, and cortisol) and GC-MS (additional steroids), hepatic aminotransferases and bilirubin in women with ICP (n = 15, total bile acids (TBA) >8 μM) and corresponding controls (n = 17). An age-adjusted linear model, receiver-operating characteristics (ROC), and multivariate regression (a method of orthogonal projections to latent structure, OPLS) were used for data evaluation. While aminotransferases, conjugates of pregnanediols, 17-hydroxypregnenolone and 5β-androstane-3α,17β-diol were higher in ICP patients, 20α-dihydropregnenolone, 16α-hydroxy-steroids, sulfated 17-oxo-C19-steroids, and 5β-reduced steroids were lower. The OPLS model including steroids measured by GC-MS and RIA showed 93.3% sensitivity and 100% specificity, while the model including steroids measured by GC-MS in a single sample aliquot showed 93.3% sensitivity and 94.1% specificity. A composite index including ratios of sulfated 3α/β-hydroxy-5α/β-androstane-17-ones to conjugated 5α/β-pregnane-3α/β, 20α-diols discriminated with 93.3% specificity and 81.3% sensitivity (ROC analysis). These new data demonstrating altered steroidogenesis in ICP patients offer more detailed pathophysiological insights into the role of steroids in the development of ICP. PMID:27494119

  17. A screening-level modeling approach to estimate nitrogen ...

    EPA Pesticide Factsheets

    This paper presents a screening-level modeling approach that can be used to rapidly estimate nutrient loading and assess numerical nutrient standard exceedance risk of surface waters leading to potential classification as impaired for designated use. It can also be used to explore best management practice (BMP) implementation to reduce loading. The modeling framework uses a hybrid statistical and process based approach to estimate source of pollutants, their transport and decay in the terrestrial and aquatic parts of watersheds. The framework is developed in the ArcGIS environment and is based on the total maximum daily load (TMDL) balance model. Nitrogen (N) is currently addressed in the framework, referred to as WQM-TMDL-N. Loading for each catchment includes non-point sources (NPS) and point sources (PS). NPS loading is estimated using export coefficient or event mean concentration methods depending on the temporal scales, i.e., annual or daily. Loading from atmospheric deposition is also included. The probability of a nutrient load to exceed a target load is evaluated using probabilistic risk assessment, by including the uncertainty associated with export coefficients of various land uses. The computed risk data can be visualized as spatial maps which show the load exceedance probability for all stream segments. In an application of this modeling approach to the Tippecanoe River watershed in Indiana, USA, total nitrogen (TN) loading and risk of standard exce

  18. Evidence of insulin-like growth factor binding protein-3 proteolysis during growth hormone stimulation testing.

    PubMed

    Nwosu, Benjamin U; Soyka, Leslie A; Angelescu, Amanda; Lee, Mary M

    2011-01-01

    The ternary complex is composed of insulin-like growth factor (IGF)-I, IGF binding protein (IGFBP)-3 and acid labile subunit (ALS). Growth hormone (GH) promotes IGFBP-3 proteolysis to release free IGF-I, ALS, and IGFBP-3 fragments. Our aim was to determine whether elevated GH levels during GH stimulation testing would trigger IGFBP-3 proteolysis. This prospective study of 10 short prepubertal children (height standard deviation score -2.37 +/- 0.31) used arginine and GH releasing hormone stimulation to study dynamic changes in the ternary complex moieties. IGFBP-3 was measured in two assays: a radioimmunoassay (RIA) that detects both cleaved and intact IGFBP-3; and an immunochemiluminescence assay (ICMA) that detects only intact IGFBP-3. IGFBP-3 measured by RIA increased by 19% (p < 0.05), while IGFBP-3 measured by ICMA did not significantly increase (6.1%). The significant increase in IGFBP-3 measured by RIA, but not ICMA, provides evidence of IGFBP-3 proteolysis during acute GH stimulation.

  19. Brominated Flame Retardants in Sediments of Four Coastal Lagoons of Yucatan, Mexico.

    PubMed

    Valenzuela-Sánchez, I S; Gold-Bouchot, G; Hernández-Núñez, E; Barrientos-Medina, R C; Garza-Gisholt, E; Zapata-Pérez, O

    2018-05-02

    We examined the sediments of four coastal lagoons (Ria Lagartos, Bocas de Dzilam, Laguna de Chelem and Ria Celestun) from the state of Yucatan, Mexico, for three widely used commercial polybrominated diphenyl ethers formulations (penta-, octa- and deca-BDE). The most commonly found congeners in all four lagoons were BDEs 47, 99 and 100 (all in the penta-BDE formulation) and BDE209 (deca-BDE formulation). The greatest variety and highest concentrations of brominated flame retardants were found in Ria Lagartos, which also showed the highest BDE 100 concentration (24.129 ng/g). Hexabromocyclododecane was found in all lagoons, but at lower concentrations than those of the various polybrominated diphenyl ethers. Dispersal routes of these compounds are discussed, such as a ring of sinkholes (cenotes) adjacent to the lagoons. Moreover, electronic waste is a serious problem because municipal landfills have been the primary disposal method for these wastes and therefore represent a reservoir of brominated fire retardants.

  20. Retinal imaging analysis based on vessel detection.

    PubMed

    Jamal, Arshad; Hazim Alkawaz, Mohammed; Rehman, Amjad; Saba, Tanzila

    2017-07-01

    With an increase in the advancement of digital imaging and computing power, computationally intelligent technologies are in high demand to be used in ophthalmology cure and treatment. In current research, Retina Image Analysis (RIA) is developed for optometrist at Eye Care Center in Management and Science University. This research aims to analyze the retina through vessel detection. The RIA assists in the analysis of the retinal images and specialists are served with various options like saving, processing and analyzing retinal images through its advanced interface layout. Additionally, RIA assists in the selection process of vessel segment; processing these vessels by calculating its diameter, standard deviation, length, and displaying detected vessel on the retina. The Agile Unified Process is adopted as the methodology in developing this research. To conclude, Retina Image Analysis might help the optometrist to get better understanding in analyzing the patient's retina. Finally, the Retina Image Analysis procedure is developed using MATLAB (R2011b). Promising results are attained that are comparable in the state of art. © 2017 Wiley Periodicals, Inc.

  1. Rapid enzymatic degradation of (/sup 125/I) (Tyr 10) FGF (1-10) by serum in vitro and involvement in the determination of circulating FGF by RIA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gauthier, T.; Maftouh, M.; Picard, C.

    1987-06-15

    In the conditions used in the RIA procedure for circulating FGF quantitation, the tracer (/sup 125/I) (Tyr 10) FGF (1-10) was extensively degraded into two non immunoreactive peptides corresponding to a sequential removal of two amino acid residues at the NH2-terminus i.e. Pro and Ala. A FGF like immunoreactive fraction exists in serum the molecular weight of which was estimated to be 240 Kda. This fraction was also able to perform the same extensive degradation of (Tyr 10) FGF (1-10) than whole serum. The results presented raise the question of the validity of RIA for the determination of circulating FGF.more » They also present evidence that a high molecular weight serum fraction which reacts as immunoreactive FGF is an enzymatic activity responsible for biodegradation of the growth factor rather than a distinct biological entity which is related to the FGF structure.« less

  2. The neuropeptide NLP-22 regulates a sleep-like state in Caenorhabditis elegans

    PubMed Central

    Nelson, MD; Trojanowski, NF; George-Raizen, JB; Smith, CJ; Yu, C-C; Fang-Yen, C; Raizen, DM

    2013-01-01

    Neuropeptides play central roles in the regulation of homeostatic behaviors such as sleep and feeding. Caenorhabditis elegans displays sleep-like quiescence of locomotion and feeding during a larval transition stage called lethargus and feeds during active larval and adult stages. Here we show that the neuropeptide NLP-22 is a regulator of Caenorhabditis elegans sleep-like quiescence observed during lethargus. nlp-22 shows cyclical mRNA expression in synchrony with lethargus; it is regulated by LIN-42, an orthologue of the core circadian protein PERIOD; and it is expressed solely in the two RIA interneurons. nlp-22 and the RIA interneurons are required for normal lethargus quiescence, and forced expression of nlp-22 during active stages causes anachronistic locomotion and feeding quiescence. Optogenetic stimulation of RIA interneurons has a movement-promoting effect, demonstrating functional complexity in a single neuron type. Our work defines a quiescence-regulating role for NLP-22 and expands our knowledge of the neural circuitry controlling Caenorhabditis elegans behavioral quiescence. PMID:24301180

  3. The neuropeptide NLP-22 regulates a sleep-like state in Caenorhabditis elegans.

    PubMed

    Nelson, M D; Trojanowski, N F; George-Raizen, J B; Smith, C J; Yu, C-C; Fang-Yen, C; Raizen, D M

    2013-01-01

    Neuropeptides have central roles in the regulation of homoeostatic behaviours such as sleep and feeding. Caenorhabditis elegans displays sleep-like quiescence of locomotion and feeding during a larval transition stage called lethargus and feeds during active larval and adult stages. Here we show that the neuropeptide NLP-22 is a regulator of Caenorhabditis elegans sleep-like quiescence observed during lethargus. nlp-22 shows cyclical mRNA expression in synchrony with lethargus; it is regulated by LIN-42, an orthologue of the core circadian protein PERIOD; and it is expressed solely in the two RIA interneurons. nlp-22 and the RIA interneurons are required for normal lethargus quiescence, and forced expression of nlp-22 during active stages causes anachronistic locomotion and feeding quiescence. Optogenetic stimulation of the RIA interneurons has a movement-promoting effect, demonstrating functional complexity in a single-neuron type. Our work defines a quiescence-regulating role for NLP-22 and expands our knowledge of the neural circuitry controlling Caenorhabditis elegans behavioural quiescence.

  4. Use of model calibration to achieve high accuracy in analysis of computer networks

    DOEpatents

    Frogner, Bjorn; Guarro, Sergio; Scharf, Guy

    2004-05-11

    A system and method are provided for creating a network performance prediction model, and calibrating the prediction model, through application of network load statistical analyses. The method includes characterizing the measured load on the network, which may include background load data obtained over time, and may further include directed load data representative of a transaction-level event. Probabilistic representations of load data are derived to characterize the statistical persistence of the network performance variability and to determine delays throughout the network. The probabilistic representations are applied to the network performance prediction model to adapt the model for accurate prediction of network performance. Certain embodiments of the method and system may be used for analysis of the performance of a distributed application characterized as data packet streams.

  5. Liquid Rocket Booster (LRB) for the Space Transportation System (STS) systems study. Appendix E: Pressure-fed booster test bed for the liquid rocket booster study

    NASA Technical Reports Server (NTRS)

    1989-01-01

    The stress analysis/structural design of the Pressure-Fed Booster Engine Test Bed using the existing F-1 Test Facility Test Stand at Huntsville, Alabama is described. The analysis has been coded and set up for solution on NASTRAN. A separate stress program was established to take the NASTRAN output and perform stress checks on the members. Joint checks and other necessary additional checks were performed by hand. The notes include a brief description of other programs which assist in reproducing and reviewing the NASTRAN results. The redesign of the test stand members and the stress analysis was performed per the A.I.S.C. Code. Loads on the stand consist of the loaded run tanks; wind loads; seismic loads; live loads consisting of snow and ice: live and dead loads of steel; and loaded pressurant bottle. In combining loads, wind loads and seismic loads were each combined with full live loads. Wind and seismic loads were not combined. No one third increase in allowables was taken for the environmental loads except at decks 147 and 214, where the increase was used when considering the stay rods, brackets and stay beams. Wind and seismic loads were considered from each of the four coordinate directions (i.e. N,S,E,W) to give eight basic conditions. The analysis was run with the pressurant tank mounted at level 125. One seismic condition was also run with the tank mounted at levels 169 and 214. No failures were noted with mounting at level 169, but extensive deck failure with mounting at level 214 (the loadsets used are included on the tape, but no detailed results are included in the package). Decking support beams at levels 147 and 214 are not included in the model. The stress program thus does not reduce strut lengths to the length between support beams (the struts are attached to the beams at intersection points) and gives stress ratios larger than one for some of the struts. The affected members were therefore checked by hand.

  6. How much is too much? (Part 2) International Olympic Committee consensus statement on load in sport and risk of illness

    PubMed Central

    Schwellnus, Martin; Alonso, Juan-Manuel; Bahr, Roald; Clarsen, Ben; Dijkstra, H Paul; Gabbett, Tim J; Gleeson, Michael; Hutchinson, Mark R; Janse Van Rensburg, Christa; Meeusen, Romain; Orchard, John W; Pluim, Babette M; Raftery, Martin; Budgett, Richard; Engebretsen, Lars

    2016-01-01

    The modern-day athlete participating in elite sports is exposed to high training loads and increasingly saturated competition calendar. Emerging evidence indicates that inappropriate load management is a significant risk factor for acute illness and the overtraining syndrome. The IOC convened an expert group to review the scientific evidence for the relationship of load—including rapid changes in training and competition load, competition calendar congestion, psychological load and travel—and health outcomes in sport. This paper summarises the results linking load to risk of illness and overtraining in athletes, and provides athletes, coaches and support staff with practical guidelines for appropriate load management to reduce the risk of illness and overtraining in sport. These include guidelines for prescription of training and competition load, as well as for monitoring of training, competition and psychological load, athlete well-being and illness. In the process, urgent research priorities were identified. PMID:27535991

  7. Sources and timing of anthropogenic pollution in the Ensenada de San Simon (inner Ria de Vigo), Galicia, NW Spain: an application of mixture-modelling and nonlinear optimization to recent sedimentation.

    PubMed

    Howarth, Richard J; Evans, Graham; Croudace, Ian W; Cundy, Andrew B

    2005-03-20

    The Ensenada de San Simon is the inner part of the Ria de Vigo, one of the major mesotidal rias of the Galician coast, NW Spain. The geochemistry of its bottom sediments can be accounted for in terms of both natural and anthropogenic sources. Mixture-modelling enables much of the Cr, Ni, V, Cu, Pb and Zn concentrations of the bottom and subaqueous sediments to be explained by sediment input from the river systems and faecal matter from manmade mussel rafts. The compositions and relative contributions of additional, unknown, sources of anomalous heavy-metal concentrations are quantified using constrained nonlinear optimization. The pattern of metal enrichment is attributed to: material carried in solution and suspension in marine water entering the Ensenada from the polluted industrial areas of the adjacent Ria de Vigo; wind-borne urban dusts and/or vehicular emissions from the surrounding network of roads and a motorway road-bridge over the Estrecho de Rande; industrial and agricultural pollution from the R. Redondela; and waste from a former ceramics factory near the mouth of the combined R. Oitaben and R. Verdugo. Using (137)Cs dating, it is suggested that heavy metal build-up in the sediments since the late 1970s followed development of inshore fisheries and introduction of the mussel rafts (ca. 1960) and increasing industrialisation.

  8. Load research manual. Volume 3. Load research for advanced technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. The manual includes guides to load research literature and glossaries of load research and statistical terms. In Volume 3, special load research procedures are presented for solar, wind, and cogeneration technologies.

  9. Apparatus and method for optimal phase balancing using dynamic programming with spatial consideration

    DOEpatents

    Robertazzi, Thomas G.; Skiena, Steven; Wang, Kai

    2017-08-08

    Provided are an apparatus and method for load-balancing of a three-phase electric power distribution system having a multi-phase feeder, including obtaining topology information of the feeder identifying supply points for customer loads and feeder sections between the supply points, obtaining customer information that includes peak customer load at each of the points between each of the feeder sections, performing a phase balancing analysis, and recommending phase assignment at the customer load supply points.

  10. How much is too much? (Part 1) International Olympic Committee consensus statement on load in sport and risk of injury.

    PubMed

    Soligard, Torbjørn; Schwellnus, Martin; Alonso, Juan-Manuel; Bahr, Roald; Clarsen, Ben; Dijkstra, H Paul; Gabbett, Tim; Gleeson, Michael; Hägglund, Martin; Hutchinson, Mark R; Janse van Rensburg, Christa; Khan, Karim M; Meeusen, Romain; Orchard, John W; Pluim, Babette M; Raftery, Martin; Budgett, Richard; Engebretsen, Lars

    2016-09-01

    Athletes participating in elite sports are exposed to high training loads and increasingly saturated competition calendars. Emerging evidence indicates that poor load management is a major risk factor for injury. The International Olympic Committee convened an expert group to review the scientific evidence for the relationship of load (defined broadly to include rapid changes in training and competition load, competition calendar congestion, psychological load and travel) and health outcomes in sport. We summarise the results linking load to risk of injury in athletes, and provide athletes, coaches and support staff with practical guidelines to manage load in sport. This consensus statement includes guidelines for (1) prescription of training and competition load, as well as for (2) monitoring of training, competition and psychological load, athlete well-being and injury. In the process, we identified research priorities. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  11. How much is too much? (Part 2) International Olympic Committee consensus statement on load in sport and risk of illness.

    PubMed

    Schwellnus, Martin; Soligard, Torbjørn; Alonso, Juan-Manuel; Bahr, Roald; Clarsen, Ben; Dijkstra, H Paul; Gabbett, Tim J; Gleeson, Michael; Hägglund, Martin; Hutchinson, Mark R; Janse Van Rensburg, Christa; Meeusen, Romain; Orchard, John W; Pluim, Babette M; Raftery, Martin; Budgett, Richard; Engebretsen, Lars

    2016-09-01

    The modern-day athlete participating in elite sports is exposed to high training loads and increasingly saturated competition calendar. Emerging evidence indicates that inappropriate load management is a significant risk factor for acute illness and the overtraining syndrome. The IOC convened an expert group to review the scientific evidence for the relationship of load-including rapid changes in training and competition load, competition calendar congestion, psychological load and travel-and health outcomes in sport. This paper summarises the results linking load to risk of illness and overtraining in athletes, and provides athletes, coaches and support staff with practical guidelines for appropriate load management to reduce the risk of illness and overtraining in sport. These include guidelines for prescription of training and competition load, as well as for monitoring of training, competition and psychological load, athlete well-being and illness. In the process, urgent research priorities were identified. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Rapid method for the measurement of circulating thyroid hormones in low volumes of teleost fish plasma by LC-ESI/MS/MS

    PubMed Central

    Noyes, Pamela D.; Lema, Sean C.; Roberts, Simon C.; Cooper, Ellen M.

    2014-01-01

    Thyroid hormones are critical regulators of normal development and physiological functioning in all vertebrates. Radioimmunoassay (RIA) approaches have been the method of choice for measuring circulating levels of thyroid hormones in vertebrates. While sensitive, RIA-based approaches only allow for a single analyte measurement per assay, can lack concordance across platforms and laboratories, and can be prone to analytical interferences especially when used with fish plasma. Ongoing advances in liquid chromatography tandem mass spectrometry (LC/MS/MS) have led to substantial decreases in detection limits for thyroid hormones and other biomolecules in complex matrices, including human plasma. Despite these advances, current analytical approaches do not allow for the measurement of native thyroid hormone in teleost fish plasma by mass spectrometry and continue to rely on immunoassay. In this study, we developed a new method that allows for the rapid extraction and simultaneous measurement of total T4 (TT4) and total T3 (TT3) in low volumes (50 μL) of fish plasma by LC/MS/MS. Methods were optimized initially in plasma from rainbow trout (Oncorhynchus mykiss) and applied to plasma from other teleost fishes, including fathead minnows (Pimephales promelas), mummichogs (Fundulus heteroclitus), sockeye salmon (Oncorhynchus nerka), and coho salmon (Oncorhynchus kisutch). Validation of method performance with T4- and T3-spiked rainbow trout plasma at 2 and 4 ng/mL produced mean recoveries ranging from 82 to 95 % and 97 to 105 %, respectively. Recovery of 13C12-T4 internal standard in plasma extractions was: 99±1.8 % in rainbow trout, 85±11 % in fathead minnow, 73±5.0 % in mummichog, 73±1.7 % in sockeye salmon, and 80±8.4 % in coho salmon. While absolute levels of thyroid hormones measured in identical plasma samples by LC/MS/MS and RIA varied depending on the assay used, T4/T3 ratios were generally consistent across both techniques. Less variability was measured among samples subjected to LC/MS/MS suggesting a more precise estimate of thyroid hormone homeostasis in the species targeted. Overall, a sensitive and reproducible method was established that takes advantage of LC/MS/MS techniques to rapidly measure TT4 and TT3 with negligible interferences in low volumes of plasma across a variety of teleost fishes. PMID:24343452

  13. Reduced Nucleus Pulposus Glycosaminoglycan Content Alters Intervertebral Disc Dynamic Viscoelastic Mechanics

    PubMed Central

    Boxberger, John I.; Orlansky, Amy S.; Sen, Sounok; Elliott, Dawn M.

    2009-01-01

    The intervertebral disc functions over a range of dynamic loading regimes including axial loads applied across a spectrum of frequencies at varying compressive loads. Biochemical changes occurring in early degeneration, including reduced nucleus pulposus glycosaminoglycan content, may alter disc mechanical behavior and thus may contribute to the progression of degeneration. The objective of this study was to determine disc dynamic viscoelastic properties under several equilibrium loads and loading frequencies, and further, to determine how reduced nucleus glycosaminglycan content alters dynamic mechanics. We hypothesized (1) that dynamic stiffness would be elevated with increasing equilibrium load and increasing frequency, (2) that the disc would behave more elastically at higher frequencies, and finally, (3) that dynamic stiffness would be reduced at low equilibrium loads under all frequencies due to nucleus glycosaminoglycan loss. We mechanically tested control and chondroitinase-ABC injected rat lumbar motion segments at several equilibrium loads using oscillatory loading at frequencies ranging from 0.05 to 5 Hz. The rat lumbar disc behaved non-linearly with higher dynamic stiffness at elevated compressive loads irrespective of frequency. Phase angle was not affected by equilibrium load, although it decreased as frequency was increased. Reduced glycosaminoglycan decreased dynamic stiffness at low loads but not at high equilibrium loads and led to increased phase angle at all loads and frequencies. The findings of this study demonstrate the effect of equilibrium load and loading frequencies on dynamic disc mechanics and indicate possible mechanical mechanisms through which disc degeneration can progress. PMID:19539936

  14. Using spatially detailed water-quality data and solute-transport modeling to improve support total maximum daily load development

    USGS Publications Warehouse

    Walton-Day, Katherine; Runkel, Robert L.; Kimball, Briant A.

    2012-01-01

    Spatially detailed mass-loading studies and solute-transport modeling using OTIS (One-dimensional Transport with Inflow and Storage) demonstrate how natural attenuation and loading from distinct and diffuse sources control stream water quality and affect load reductions predicted in total maximum daily loads (TMDLs). Mass-loading data collected during low-flow from Cement Creek (a low-pH, metal-rich stream because of natural and mining sources, and subject to TMDL requirements) were used to calibrate OTIS and showed spatially variable effects of natural attenuation (instream reactions) and loading from diffuse (groundwater) and distinct sources. OTIS simulations of the possible effects of TMDL-recommended remediation of mine sites showed less improvement to dissolved zinc load and concentration (14% decrease) than did the TMDL (53-63% decrease). The TMDL (1) assumed conservative transport, (2) accounted for loads removed by remediation by subtracting them from total load at the stream mouth, and (3) did not include diffuse-source loads. In OTIS, loads were reduced near their source; the resulting concentration was decreased by natural attenuation and increased by diffuse-source loads during downstream transport. Thus, by not including natural attenuation and loading from diffuse sources, the TMDL overestimated remediation effects at low flow. Use of the techniques presented herein could improve TMDLs by incorporating these processes during TMDL development.

  15. Comparison of the Immulite and RIA assay methods for measuring peripheral blood progesterone levels in Greyhound bitches.

    PubMed

    Chapwanya, A; Clegg, T; Stanley, P; Vaughan, L

    2008-09-15

    Determination of optimal breeding time in bitches earmarked for single insemination only is based on measurement of peripheral blood serum or plasma progesterone concentration. In this paper a comparison is made between radioimmune assay (RIA) and chemoluminescent assay (Immulite) for determination of P4 concentrations in the bitch. The Immulite assay is shown to be an accurate and reliable method for serum or plasma P4 measurement. It compares favourably with other methods in terms of turn-around time, cost and accessibility for veterinarians in practice.

  16. Anomalies in Trace Metal and Rare-Earth Loads below a Waste-Water Treatment Plant

    NASA Astrophysics Data System (ADS)

    Antweiler, R.; Writer, J. H.; Murphy, S.

    2013-12-01

    The changes in chemical loads were examined for 54 inorganic elements and compounds in a 5.4-km reach of Boulder Creek, Colorado downstream of a waste water treatment plant (WWTP) outfall. Elements were partitioned into three categories: those showing a decrease in loading downstream, those showing an increase, and those which were conservative, at least over the length of the study reach. Dissolved loads which declined - generally indicative of in-stream loss via precipitation or sorption - were typically rapid (occurring largely before the first sampling site, 2.3 km downstream); elements showing this behavior were Bi, Cr, Cs, Ga, Ge, Hg, Se and Sn. These results were as expected before the experiment was performed. However, a large group (28 elements, including all the rare-earth elements, REE, except Gd) exhibited dissolved load increases indicating in-stream gains. These gains may be due to particulate matter dissolving or disaggregating, or that desorption is occurring below the WWTP. As with the in-stream loss group, the processes tended to be rapid, typically occurring before the first sampling site. Whole-water samples collected concurrently also had a large group of elements which showed an increase in load downstream of the WWTP. Among these were most of the group which had increases in the dissolved load, including all the REE (except Gd). Because whole-water samples include both dissolved and suspended particulates within them, increases in loads cannot be accounted for by invoking desorption or disaggregation mechanisms; thus, the only source for these increases is from the bed load of the stream. Further, the difference between the whole-water and dissolved loads is a measure of the particulate load, and calculations show that not only did the dissolved and whole-water loads increase, but so did the particulate loads. This implies that at the time of sampling the bed sediment was supplying a significant contribution to the suspended load. In general, it seems untenable as a hypothesis to suppose that the stream bed material can permanently supply the source of the in-stream load increases of a large group of inorganic elements. We propose that the anomalous increase in loads was more a function of the time of sampling (both diurnally and seasonally) and that sampling at different times of day or different seasons during the year would give contradictory results to those seen here. If this is so, inorganic loading studies must include multiple sampling both over the course of a day and during different seasons and flow regimes.

  17. GGFC Special Bureau for Loading: current status and plans

    NASA Astrophysics Data System (ADS)

    van Dam, T.; Plag, H.-P.; Francis, O.; Gegout, P.

    The Earth's surface is perpetually being displaced due to temporally varying atmospheric, oceanic and continental water mass surface loads. These non-geodynamic signals are of substantial magnitude that they contribute significantly to the scatter in geodetic observations of crustal motion. In February, 2002, the International Earth Rotation Service (IERS) established a Special Bureau of Loading (SBL) whose primary charge is to provide consistent and valid estimates of surface mass loading effects to the IERS community for the purpose of correcting geodetic time series. Here we outline the primary principles involved in modelling the surface displacements and gravity changes induced by surface mass loading including the basic theory, the Earth model and the surface load data. We then identify a list of operational issues, including product validation, that need to be addressed by the SBL before products can be provided to the community. Finally, we outline areas for future research to further improve the loading estimates. We conclude by formulating a recommendation on the best procedure for including loading corrections into geodetic data. Success of the SBL will depend on our ability to efficiently provide consistent and reliable estimates of surface mass loading effects. It is imperative that we work closely with the existing Global Geophysical Fluids Center (GGFC) Special Bureaus and with the community to as much as possible to verify the products.

  18. Fatigue data for polyether ether ketone (PEEK) under fully-reversed cyclic loading

    PubMed Central

    Shrestha, Rakish; Simsiriwong, Jutima; Shamsaei, Nima

    2016-01-01

    In this article, the data obtained from the uniaxial fully-reversed fatigue experiments conducted on polyether ether ketone (PEEK), a semi-crystalline thermoplastic, are presented. The tests were performed in either strain-controlled or load-controlled mode under various levels of loading. The data are categorized into four subsets according to the type of tests, including (1) strain-controlled fatigue tests with adjusted frequency to obtain the nominal temperature rise of the specimen surface, (2) strain-controlled fatigue tests with various frequencies, (3) load-controlled fatigue tests without step loadings, and (4) load-controlled fatigue tests with step loadings. Accompanied data for each test include the fatigue life, the maximum (peak) and minimum (valley) stress–strain responses for each cycle, and the hysteresis stress–strain responses for each collected cycle in a logarithmic increment. A brief description of the experimental method is also given. PMID:26937465

  19. Fatigue data for polyether ether ketone (PEEK) under fully-reversed cyclic loading.

    PubMed

    Shrestha, Rakish; Simsiriwong, Jutima; Shamsaei, Nima

    2016-03-01

    In this article, the data obtained from the uniaxial fully-reversed fatigue experiments conducted on polyether ether ketone (PEEK), a semi-crystalline thermoplastic, are presented. The tests were performed in either strain-controlled or load-controlled mode under various levels of loading. The data are categorized into four subsets according to the type of tests, including (1) strain-controlled fatigue tests with adjusted frequency to obtain the nominal temperature rise of the specimen surface, (2) strain-controlled fatigue tests with various frequencies, (3) load-controlled fatigue tests without step loadings, and (4) load-controlled fatigue tests with step loadings. Accompanied data for each test include the fatigue life, the maximum (peak) and minimum (valley) stress-strain responses for each cycle, and the hysteresis stress-strain responses for each collected cycle in a logarithmic increment. A brief description of the experimental method is also given.

  20. Optical based tactile shear and normal load sensor

    DOEpatents

    Salisbury, Curt Michael

    2015-06-09

    Various technologies described herein pertain to a tactile sensor that senses normal load and/or shear load. The tactile sensor includes a first layer and an optically transparent layer bonded together. At least a portion of the first layer is made of optically reflective material. The optically transparent layer is made of resilient material (e.g., clear silicone rubber). The tactile sensor includes light emitter/light detector pair(s), which respectively detect either normal load or shear load. Light emitter(s) emit light that traverses through the optically transparent layer and reflects off optically reflective material of the first layer, and light detector(s) detect and measure intensity of reflected light. When a normal load is applied, the optically transparent layer compresses, causing a change in reflected light intensity. When shear load is applied, a boundary between optically reflective material and optically absorptive material is laterally displaced, causing a change in reflected light intensity.

  1. Film riding seal assembly for turbomachinery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bidkar, Rahul Anil; Giametta, Andrew Paul; Gibson, Nathan Evan McCurdy

    2016-06-07

    An aerodynamic seal assembly for a rotary machine includes multiple sealing segments disposed circumferentially intermediate to a stationary housing and a rotor. Each of the segments includes a shoe plate with a forward load-bearing section and an aft load-bearing section configured to generate an aerodynamic force between the shoe plate and the rotor. The shoe plate includes at least one labyrinth teeth facing the rotor and positioned between the forward load-bearing section and the aft load-bearing section. The sealing segment also includes at least one spring connected to a pedestal located about midway of an axial length of the shoemore » plate and to a stator interface element. Further, the sealing segment includes a rigid segmented secondary seal attached to the stator interface element at one first end and in contact with the pedestal of the shoe plate at one second end.« less

  2. Linear transformer driver for pulse generation

    DOEpatents

    Kim, Alexander A; Mazarakis, Michael G; Sinebryukhov, Vadim A; Volkov, Sergey N; Kondratiev, Sergey S; Alexeenko, Vitaly M; Bayol, Frederic; Demol, Gauthier; Stygar, William A

    2015-04-07

    A linear transformer driver includes at least one ferrite ring positioned to accept a load. The linear transformer driver also includes a first power delivery module that includes a first charge storage devices and a first switch. The first power delivery module sends a first energy in the form of a first pulse to the load. The linear transformer driver also includes a second power delivery module including a second charge storage device and a second switch. The second power delivery module sends a second energy in the form of a second pulse to the load. The second pulse has a frequency that is approximately three times the frequency of the first pulse. The at least one ferrite ring is positioned to force the first pulse and the second pulse to the load by temporarily isolating the first pulse and the second pulse from an electrical ground.

  3. Round Heat-treated Chromium-molybdenum-steel Tubing Under Combined Loads

    NASA Technical Reports Server (NTRS)

    Osgood, William R

    1943-01-01

    The results of tests of round heat-treated chromium-molybdenum-steel tubing are presented. Tests were made on tubing under axial load, bending load, torsional load, combined bending and axial load, combined bending and torsional load, and combined axial, bending, and torsional load. Tensile and compressive tests were made to determine the properties of the material. Formulas are given for the evaluation of the maximum strength of this steel tubing under individual or combined loads. The solution of an example is included to show the procedure to be followed in designing a tubular cantilever member to carry combined loads.

  4. Load research manual. Volume 2: Fundamentals of implementing load research procedures

    NASA Astrophysics Data System (ADS)

    1980-11-01

    This manual will assist electric utilities and state regulatory authorities in investigating customer electricity demand as part of cost-of-service studies, rate design, marketing research, system design, load forecasting, rate reform analysis, and load management research. Load research procedures are described in detail. Research programs at three utilities are compared: Carolina Power and Light Company, Long Island Lighting Company, and Southern California Edison Company. A load research bibliography and glossaries of load research and statistical terms are also included.

  5. Association between the concentration of fine particles in the atmosphere and acute respiratory diseases in children.

    PubMed

    Nascimento, Antônio Paula; Santos, Jane Meri; Mill, José Geraldo; Souza, Juliana Bottoni de; Reis, Neyval Costa; Reisen, Valdério Anselmo

    2017-01-12

    To analyze the association between fine particulate matter concentration in the atmosphere and hospital care by acute respiratory diseases in children. Ecological study, carried out in the region of Grande Vitória, Espírito Santo, in the winter (June 21 to September 21, 2013) and summer (December 21, 2013 to March 19, 2014). We assessed data of daily count for outpatient care and hospitalization by respiratory diseases (ICD-10) in children from zero to 12 years in three hospitals in the Region of Grande Vitória. For collecting fine particulate matter, we used portable samplers of particles installed in six locations in the studied region. The Generalized Additive Model with Poisson distribution, fitted for the effects of predictor covariates, was used to evaluate the relationship between respiratory outcomes and concentration of fine particulate matter. The increase of 4.2 µg/m3 (interquartile range) in the concentration of fine particulate matter increased in 3.8% and 5.6% the risk of medical care or hospitalization, respectively, on the same day and with six-day lag from the exposure. We identified positive association between outpatient care and hospitalizations of children under 12 years due to acute respiratory diseases and the concentration of fine particulate matter in the atmosphere. Analisar a associação entre a concentração de material particulado fino na atmosfera e atendimento hospitalar por doenças respiratórias agudas em crianças. Estudo ecológico, realizado na Região da Grande Vitória, ES, no inverno (21 de junho a 21 de setembro de 2013) e no verão (21 de dezembro de 2013 a 19 de março de 2014). Foram avaliados dados de contagem diária de atendimentos ambulatoriais e hospitalizações por doenças respiratórias (CID-10) em crianças de zero a 12 anos em três hospitais da Região da Grande Vitoria. Para a coleta de material particulado fino foram utilizados amostradores portáteis de partículas instalados em seis locais na região estudada. O Modelo Aditivo Generalizado com distribuição de Poisson, ajustado para efeitos das covariáveis preditoras, foi utilizado para avaliar a relação entre os desfechos respiratórios e a concentração de material particulado fino. O incremento de 4,2 µg/m3 (intervalo interquartílico) na concentração de material particulado fino aumentou em 3,8% e 5,6% o risco de atendimento ou internação, respectivamente, no mesmo dia e com seis dias de defasagem da exposição. Foi identificada associação positiva entre atendimentos ambulatoriais e hospitalizações de crianças com até 12 anos devido a doenças respiratórias agudas e a concentração de material particulado fino na atmosfera.

  6. A pulse-controlled modified-burst test instrument for accident-tolerant fuel cladding

    DOE PAGES

    Cinbiz, M. Nedim; Brown, Nicholas R.; Terrani, Kurt A.; ...

    2017-06-03

    Pellet-cladding mechanical interaction due to thermal expansion of nuclear fuel pellets during a reactivity-initiated accident (RIA) is a potential mechanism for failure of nuclear fuel cladding. To investigate the mechanical behavior of cladding during an RIA, we developed a mechanical pulse-controlled modified burst test instrument that simulates transient events with a pulse width from 10 to 300 ms. This paper includes validation tests of unirradiated and prehydrided ZIRLO cladding tubes. A ZIRLO cladding sample with a hydrogen content of 168 wt. ppm showed ductile behavior and failed at the maximum limits of the test setup with hoop strain to failuremore » greater than 9.2%. ZIRLO samples showed high resistance to failure even at very high hydrogen contents (1,466 wt. ppm). When the hydrogen content was increased to 1,554 wt. ppm, brittle-like behavior was observed at a hoop strain of 2.5%. Preliminary scoping tests at room temperature with FeCrAl tubes were conducted to imitate the pulse behavior of transient test reactors during integral tests. The preliminary FeCrAl tests are informative from the perspective of characterizing the test rig and supporting the design of integral tests for current and potentially accident tolerant cladding materials.« less

  7. Chewing lice (Phthiraptera) from wild birds in southern Portugal.

    PubMed

    Tomás, André; Palma, Ricardo L; Rebelo, Maria Teresa; da Fonseca, Isabel Pereira

    2016-06-01

    This study was carried out to determine chewing louse species of wild birds in the Ria Formosa Natural Park, located in southern Portugal. In addition, the hypothesis that bird age, avian migration and social behaviour have an impact on the louse prevalence was tested. Between September and December of 2013, 122 birds (belonging to 10 orders, 19 families, 31 genera and 35 species) captured in scientific ringing sessions and admitted to the Wildlife Rehabilitation and Investigation Centre of Ria Formosa were examined for lice. Twenty-six (21.3%) birds were found to be infested with at least one chewing louse species. The chewing lice identified include 18 species. Colonial birds (34.9%) and migratory birds (29.5%) had statistically significant higher prevalence than territorial birds (6.8%) and resident birds (13.1%), respectively. This paper records 17 louse species for the first time in southern Portugal: Laemobothrion maximum, Laemobothrion vulturis, Actornithophilus piceus lari, Actornithophilus umbrinus, Austromenopon lutescens, Colpocephalum heterosoma, Colpocephalum turbinatum, Eidmanniella pustulosa, Nosopon casteli, Pectinopygus bassani, Pseudomenopon pilosum, Trinoton femoratum, Trinoton querquedulae, Craspedorrhynchus platystomus, Degeeriella fulva, Falcolipeurus quadripustulatus, Lunaceps schismatus. Also a nymph of the genus Strigiphilus was collected from a Eurasian eagle-owl. These findings contribute to the knowledge of avian chewing lice from important birds areas in Portugal. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. A pulse-controlled modified-burst test instrument for accident-tolerant fuel cladding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cinbiz, M. Nedim; Brown, Nicholas R.; Terrani, Kurt A.

    Pellet-cladding mechanical interaction due to thermal expansion of nuclear fuel pellets during a reactivity-initiated accident (RIA) is a potential mechanism for failure of nuclear fuel cladding. To investigate the mechanical behavior of cladding during an RIA, we developed a mechanical pulse-controlled modified burst test instrument that simulates transient events with a pulse width from 10 to 300 ms. This paper includes validation tests of unirradiated and prehydrided ZIRLO cladding tubes. A ZIRLO cladding sample with a hydrogen content of 168 wt. ppm showed ductile behavior and failed at the maximum limits of the test setup with hoop strain to failuremore » greater than 9.2%. ZIRLO samples showed high resistance to failure even at very high hydrogen contents (1,466 wt. ppm). When the hydrogen content was increased to 1,554 wt. ppm, brittle-like behavior was observed at a hoop strain of 2.5%. Preliminary scoping tests at room temperature with FeCrAl tubes were conducted to imitate the pulse behavior of transient test reactors during integral tests. The preliminary FeCrAl tests are informative from the perspective of characterizing the test rig and supporting the design of integral tests for current and potentially accident tolerant cladding materials.« less

  9. Instrumentation, control and data management for the MIST (Modular Integrated Utility System) Facility

    NASA Technical Reports Server (NTRS)

    Celino, V. A.

    1977-01-01

    An appendix providing the technical data required for computerized control and/or monitoring of selected MIST subsystems is presented. Specific computerized functions to be performed are as follows: (1) Control of the MIST heating load simulator and monitoring of the diesel engine generators' cooling system; (2) Control of the MIST heating load simulator and MIST heating subsystem including the heating load simulator; and (3) Control of the MIST air conditioning load simulator subsystem and the MIST air conditioning subsystem, including cold thermal storage and condenser water flows.

  10. Real-time terminal area trajectory planning for runway independent aircraft

    NASA Astrophysics Data System (ADS)

    Xue, Min

    The increasing demand for commercial air transportation results in delays due to traffic queues that form bottlenecks along final approach and departure corridors. In urban areas, it is often infeasible to build new runways, and regardless of automation upgrades traffic must remain separated to avoid the wakes of previous aircraft. Vertical or short takeoff and landing aircraft as Runway Independent Aircraft (RIA) can increase passenger throughput at major urban airports via the use of vertiports or stub runways. The concept of simultaneous non-interfering (SNI) operations has been proposed to reduce traffic delays by creating approach and departure corridors that do not intersect existing fixed-wing routes. However, SNI trajectories open new routes that may overfly noise-sensitive areas, and RIA may generate more noise than traditional jet aircraft, particularly on approach. In this dissertation, we develop efficient SNI noise abatement procedures applicable to RIA. First, we introduce a methodology based on modified approximated cell-decomposition and Dijkstra's search algorithm to optimize longitudinal plane (2-D) RIA trajectories over a cost function that minimizes noise, time, and fuel use. Then, we extend the trajectory optimization model to 3-D with a k-ary tree as the discrete search space. We incorporate geography information system (GIS) data, specifically population, into our objective function, and focus on a practical case study: the design of SNI RIA approach procedures to Baltimore-Washington International airport. Because solutions were represented as trim state sequences, we incorporated smooth transition between segments to enable more realistic cost estimates. Due to the significant computational complexity, we investigated alternative more efficient optimization techniques applicable to our nonlinear, non-convex, heavily constrained, and discontinuous objective function. Comparing genetic algorithm (GA) and adaptive simulated annealing (ASA) with our original Dijkstra's algorithm, ASA is identified as the most efficient algorithm for terminal area trajectory optimization. The effects of design parameter discretization are analyzed, with results indicating a SNI procedure with 3-4 segments effectively balances simplicity with cost minimization. Finally, pilot control commands were implemented and generated via optimization-base inverse simulation to validate execution of the optimal approach trajectories.

  11. The Response of Sediments and Dissolved Organic Matter to Rapid Rainfall in the Santa Maria da Vitoria Watershed, Espírito Santo, BR

    NASA Astrophysics Data System (ADS)

    Ward, N. D.; Firme de Almeida, L.; Dias, G.; Gould, R.; Tan, A.; Bianchi, T. S.; Krusche, A. V.; Keil, R. G.; Richey, J. E.

    2015-12-01

    The Santa Maria da Vitória River supplies over 30% of the water for the greater Vitória, Espírito Santo, BR metropolitan area, which has a population of roughly 1.6 million people. The availability of clean freshwater is severely limited during periods of heavy rainfall because water sanitation facilities are "clogged" by high sediment discharge. The headwaters of the Santa Maria da Vitória River are characterized by relatively pristine forested environments, transitioning into primarily agricultural and rural land uses, and finally reaching the large urban center of Vitória near its marine receiving waters. The discharge of suspended sediments and dissolved organic matter (DOM) was examined at a 3 hour frequency during heavy storm flows from October 2013 to May 2015 in the Santa Maria da Vitória River main channel and a small tributary, the Mangaraí River. Bulk isotopic analyses were used to determine potential sediment sources and whether specific landscape/land use features were functionalized during periods of high runoff. Likewise, time of flight mass spectrometry (GC-ToF-MS) was used to identify a broad suite of DOM compounds that responded positively with river discharge in an effort to determine the influence of land use on the delivery of dissolved components to the river. For example, the abundance of compounds related to specific agricultural settings increased during storm flow along with anthropogenic DOM sources such as plasticizer and pesticide-derived compounds. Suspended sediment concentrations increased by as much as 70 times during peak river discharge relative to base flow several days earlier with similar increases in particulate organic carbon and nitrogen observed. Results from this study and previous field measurements were integrated into a coupled hydrology-sediment transport model, DHSVM, as part of a dynamic information framework with the goal of predicting water/sediment discharge to inform management and policy sectors of the state of Espírito Santo.

  12. The influence of strain rate and hydrogen on the plane-strain ductility of Zircaloy cladding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Link, T.M.; Motta, A.T.; Koss, D.A.

    1998-03-01

    The authors studied the ductility of unirradiated Zircaloy-4 cladding under loading conditions prototypical of those found in reactivity-initiated accidents (RIA), i.e.: near plane-strain deformation in the hoop direction (transverse to the cladding axis) at room temperature and 300 C and high strain rates. To conduct these studies, they developed a specimen configuration in which near plane-strain deformation is achieved in the gage section, and a testing methodology that allows one to determine both the limit strain at the onset of localized necking and the fracture strain. The experiments indicate that there is little effect of strain rate (10{sup {minus}3} tomore » 10{sup 2} s{sup {minus}1}) on the ductility of unhydrided Zircaloy tubing deformed under near plane-strain conditions at either room temperature or 300 C. Preliminary experiments on cladding containing 190 ppm hydrogen show only a small loss of fracture strain but no clear effect on limit strain. The experiments also indicate that there is a significant loss of Zircaloy ductility when surface flaws are present in the form of thickness imperfections.« less

  13. Mechanical ventilation increases substance P concentration in the vagus, sympathetic, and phrenic nerves.

    PubMed

    Balzamo, E; Joanny, P; Steinberg, J G; Oliver, C; Jammes, Y

    1996-01-01

    Substance P (SP), a neurotransmitter localized to primary sensory neurons, is found in the vagus nerve, nodose ganglion, sympathetic chain, and phrenic nerve in various animal species. However, the changes in endogeneous SP concentration under various circumstances that involve the participation of cardiorespiratory afferent nerves are still unexplored. In the present study, attention was focused on the variations in SP content measured by radioimmunoassay (RIA) in respiratory afferent nerves (vagus nerve, cervical sympathetic chain, phrenic nerve) and respiratory muscles (diaphragm, intercostal muscles) during positive inspiratory pressure (PIP) breathing alone or PIP with an expiratory threshold load (ETL) in rabbits. SP was found in all sampled structures in spontaneously breathing control animals, prevailing in the nodose ganglion. Left-versus right-sided differences were noticed in nerves. As compared with that in control animals, the SP concentration was markedly higher in vagal and sympathetic nervous structures during PIP or PIP with ETL, and also in the phrenic nerve during ETL breathing. The SP content did not vary in respiratory muscles. These observations suggest that two very common circumstances of mechanical ventilation are associated with an increased SP concentration in nervous structures participating in the control of breathing.

  14. POSTOP: Postbuckled open-stiffener optimum panels, user's manual

    NASA Technical Reports Server (NTRS)

    Biggers, S. B.; Dickson, J. N.

    1984-01-01

    The computer program POSTOP developed to serve as an aid in the analysis and sizing of stiffened composite panels that may be loaded in the postbuckling regime, is intended for the preliminary design of metal or composite panels with open-section stiffeners, subjected to multiple combined biaxial compression (or tension), shear and normal pressure load cases. Longitudinal compression, however, is assumed to be the dominant loading. Temperature, initial bow eccentricity and load eccentricity effects are included. The panel geometry is assumed to be repetitive over several bays in the longitudinal (stiffener) direction as well as in the transverse direction. Analytical routines are included to compute panel stiffnesses, strains, local and panel buckling loads, and skin/stiffener interface stresses. The resulting program is applicable to stiffened panels as commonly used in fuselage, wing, or empennage structures. The capabilities and limitations of the code are described. Instructions required to use the program and several example problems are included.

  15. Developement of watershed and reference loads for a TMDL in Charleston Harbor System, SC.

    Treesearch

    Silong Lu; Devenra Amatya; Jamie Miller

    2005-01-01

    It is essential to determine point and non-point source loads and their distribution for development of a dissolved oxygen (DO) Total Maximum Daily Load (TMDL). A series of models were developed to assess sources of oxygen-demand loadings in Charleston Harbor, South Carolina. These oxygen-demand loadings included nutrients and BOD. Stream flow and nutrient...

  16. Load power device and system for real-time execution of hierarchical load identification algorithms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Yi; Madane, Mayura Arun; Zambare, Prachi Suresh

    A load power device includes a power input; at least one power output for at least one load; and a plurality of sensors structured to sense voltage and current at the at least one power output. A processor is structured to provide real-time execution of: (a) a plurality of load identification algorithms, and (b) event detection and operating mode detection for the at least one load.

  17. Power converter using near-load output capacitance, direct inductor contact, and/or remote current sense

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coteus, Paul W.; Ferencz, Andrew; Hall, Shawn A.

    An apparatus includes a first circuit board including first components including a load, and a second circuit board including second components including switching power devices and an output inductor. Ground and output voltage contacts between the circuit boards are made through soldered or connectorized interfaces. Certain components on the first circuit board and certain components, including the output inductor, on the second circuit board act as a DC-DC voltage converter for the load. An output capacitance for the conversion is on the first circuit board with no board-to-board interface between the output capacitance and the load. The inductance of themore » board-to-board interface functions as part of the output inductor's inductance and not as a parasitic inductance. Sense components for sensing current through the output inductor are located on the first circuit board. Parasitic inductance of the board-to-board interface has less effect on a sense signal provided to a controller.« less

  18. Fat Layer from Medullary Canal Reamer Aspirate for Potential Use as a Supplemental Osteoinductive Bone Graft Material.

    PubMed

    Sinclair, Sarina S Kay; Horton, C Olsen; Jeray, Kyle J; Tanner, Stephanie L; Burgl, Karen J L

    2015-01-01

    Mesenchymal stem cells (MSCs) are of therapeutic interest to clinicians and researchers, as they have been shown to augment the osteogenic properties of bone grafts. MSCs are known to be prevalent in bone marrow, but are still limited in numbers. Hence, additional sources of MSCs are beneficial to increasing grafting potential. Aspirate material collected using the Reamer/Irrigator/Aspirator (RIA) device (Synthes; Paoli, PA) during reaming of the femoral shaft consists of three main components: bone fragments, liquid flow-through, and a fat layer. Currently, only the bone and liquid layers have been examined for osteoinductive elements, and the bone fragments are exclusively used as autologous bone graft. In the present study, a method to promote cellular outgrowth, tapping proliferative capacity from the previously discarded fatty layer of RIA aspirate, is described. Proliferating cells were successfully isolated from the bone and fatty layers of a consenting patient and found to be viable after liquid nitrogen storage. The osteogenic differentiation potential of the cells isolated from the fat and bone layers was assessed. Cells from both layers of the aspirate expressed statistically significant levels (p < 0.05) of the bone cell marker alkaline phosphatase compared to the control cells, suggesting differentiation along the osteoblastic pathway. Results from this pilot study indicate that the traditionally discarded fatty element of RIA aspirate may be a source of MSCs with bone-forming capabilities and the described isolation technique is effective. Combining the aspirate fatty and bony elements may enhance the clinical success of the RIA autograft.

  19. Simulation of temporal and spatial distribution of required irrigation water by crop models and the pan evaporation coefficient method

    NASA Astrophysics Data System (ADS)

    Yang, Yan-min; Yang, Yonghui; Han, Shu-min; Hu, Yu-kun

    2009-07-01

    Hebei Plain is the most important agricultural belt in North China. Intensive irrigation, low and uneven precipitation have led to severe water shortage on the plain. This study is an attempt to resolve this crucial issue of water shortage for sustainable agricultural production and water resources management. The paper models distributed regional irrigation requirement for a range of cultivated crops on the plain. Classic crop models like DSSAT- wheat/maize and COTTON2K are used in combination with pan-evaporation coefficient method to estimate water requirements for wheat, corn, cotton, fruit-trees and vegetables. The approach is more accurate than the static approach adopted in previous studies. This is because the combination use of crop models and pan-evaporation coefficient method dynamically accounts for irrigation requirement at different growth stages of crops, agronomic practices, and field and climatic conditions. The simulation results show increasing Required Irrigation Amount (RIA) with time. RIA ranges from 5.08×109 m3 to 14.42×109 m3 for the period 1986~2006, with an annual average of 10.6×109 m3. Percent average water use by wheat, fruit trees, vegetable, corn and cotton is 41%, 12%, 12%, 11%, 7% and 17% respectively. RIA for April and May (the period with the highest irrigation water use) is 1.78×109 m3 and 2.41×109 m3 respectively. The counties in the piedmont regions of Mount Taihang have high RIA while the central and eastern regions/counties have low irrigation requirement.

  20. Technical and financial evaluation of assays for progesterone in canine practice in the UK.

    PubMed

    Moxon, R; Copley, D; England, G C W

    2010-10-02

    The concentration of progesterone was measured in 60 plasma samples from bitches at various stages of the oestrous cycle, using commercially available quantitative and semi-quantitative ELISA test kits, as well as by two commercial laboratories undertaking radioimmunoassay (RIA). The RIA, which was assumed to be the 'gold standard' in terms of reliability and accuracy, was the most expensive method when analysing more than one sample per week, and had the longest delay in obtaining results, but had minimal requirements for practice staff time. When compared with the RIA, the quantitative ELISA had a strong positive correlation (r=0.97, P<0.05) and a sensitivity and specificity of 70.6 per cent and 100.0 per cent, respectively, and positive and negative predictive values of 100.0 per cent and 71.0 per cent, respectively, with an overall accuracy of 90.0 per cent. This method was the least expensive when analysing five or more samples per week, but had longer turnaround times than that of the semi-quantitative ELISA and required more staff time. When compared with the RIA, the semi-quantitative ELISA had a sensitivity and specificity of 100.0 per cent and 95.5 per cent, respectively, and positive and negative predictive values of 73.9 per cent and 77.8 per cent, respectively, with an overall accuracy of 89.2 per cent. This method was more expensive than the quantitative ELISA when analysing five or more samples per week, but had the shortest turnaround time and low requirements in terms of staff time.

  1. Determinação da composição química em nebulosas planetárias na direção do anticentro galáctico

    NASA Astrophysics Data System (ADS)

    Costa, R. D. D.; Uchida, M. M. M.; Maciel, W. J.

    2003-08-01

    Existe um gradiente radial de abundâncias no disco galáctico, cujo comportamento é razoavelmente bem conhecido para distâncias galactocêntricas entre 3 e 10 kpc. Foi obtido a partir de resultados derivados de nebulosas planetárias, regiões HII e estrelas, como as estrelas quentes de tipo O, B e aglomerados abertos. Com o objetivo de investigar o comportamento deste gradiente radial na região externa do disco, conhecida como anticentro galáctico, reportamos aqui os resultados finais da análise de uma amostra de nebulosas planetárias na direção do anticentro, observadas no LNA e no ESO entre 1995 e 2000. O uso de nebulosas planetárias permite o cálculo das abundâncias de elementos traçadores da evolução química do disco como oxigênio, argônio e neônio com o uso de técnicas de espectroscopia nebular. Os resultados indicam uma distribuição de abundâncias distinta daquela encontrada na vizinhança solar, mostrando que o gradiente radial diminui sensivelmente para distâncias galactocêntricas maiores que 10 kpc. Este resultado está de acordo com os mais recentes modelos de evolução química do disco, que prevêem uma diminuição ou mesmo um desaparecimento do gradiente radial no bordo externo do disco galáctico. (FAPESP/CNPq)

  2. Plutonium immobilization can loading FY99 component test report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kriikku, E.

    2000-06-01

    This report summarizes FY99 Can Loading work completed for the Plutonium Immobilization Project and it includes details about the Helium hood, cold pour cans, Can Loading robot, vision system, magnetically coupled ray cart and lifts, system integration, Can Loading glovebox layout, and an FY99 cost table.

  3. 14 CFR 27.681 - Limit load static tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.681 Limit load... which— (1) The direction of the test loads produces the most severe loading in the control system; and (2) Each fitting, pulley, and bracket used in attaching the system to the main structure is included...

  4. Cognitive load predicts point-of-care ultrasound simulator performance.

    PubMed

    Aldekhyl, Sara; Cavalcanti, Rodrigo B; Naismith, Laura M

    2018-02-01

    The ability to maintain good performance with low cognitive load is an important marker of expertise. Incorporating cognitive load measurements in the context of simulation training may help to inform judgements of competence. This exploratory study investigated relationships between demographic markers of expertise, cognitive load measures, and simulator performance in the context of point-of-care ultrasonography. Twenty-nine medical trainees and clinicians at the University of Toronto with a range of clinical ultrasound experience were recruited. Participants answered a demographic questionnaire then used an ultrasound simulator to perform targeted scanning tasks based on clinical vignettes. Participants were scored on their ability to both acquire and interpret ultrasound images. Cognitive load measures included participant self-report, eye-based physiological indices, and behavioural measures. Data were analyzed using a multilevel linear modelling approach, wherein observations were clustered by participants. Experienced participants outperformed novice participants on ultrasound image acquisition. Ultrasound image interpretation was comparable between the two groups. Ultrasound image acquisition performance was predicted by level of training, prior ultrasound training, and cognitive load. There was significant convergence between cognitive load measurement techniques. A marginal model of ultrasound image acquisition performance including prior ultrasound training and cognitive load as fixed effects provided the best overall fit for the observed data. In this proof-of-principle study, the combination of demographic and cognitive load measures provided more sensitive metrics to predict ultrasound simulator performance. Performance assessments which include cognitive load can help differentiate between levels of expertise in simulation environments, and may serve as better predictors of skill transfer to clinical practice.

  5. Convenient radioimmunoassay for urinary human choriogonadotropin without interference by urinary human lutropin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wehmann, R.E.; Harman, S.M.; Birken, S.

    1981-12-01

    We have devised a radioimmunoassay (RIA) for human choriogonadotropin (hCG) in first morning-voided urine specimens. Concanavalin A, a lectin, is used to extract and concentrate the hCG from urine. A high-affinity antiserum is used, directed to the hCG..beta.. carboxy-terminal peptide, a unique immunological determinant not shared by the beta subunit of human lutropin. This ensures that urinary human lutropin-related molecules, which interfere with RIAs involving antisera to the intact hCG..beta.. subunit, will not cross react in this assay. A concentration of hCG as low as 0.4 ..mu..g/L can be detected in the first morning-voided urine. The effective sensitivity of thismore » assay for the unequivocal detection of hCG production is somewhat better than that achieved with the serum hCG RIA involving antisera to the hCG..beta.. subunit. The improved specificity and sensitivity of this assay, and the greater convenience of collecting samples of urine rather than blood, are clinically useful advantages of this approach to assessing hCG production in humans.« less

  6. Mathematical Storage-Battery Models

    NASA Technical Reports Server (NTRS)

    Chapman, C. P.; Aston, M.

    1985-01-01

    Empirical formula represents performance of electrical storage batteries. Formula covers many battery types and includes numerous coefficients adjusted to fit peculiarities of each type. Battery and load parameters taken into account include power density in battery, discharge time, and electrolyte temperature. Applications include electric-vehicle "fuel" gages and powerline load leveling.

  7. Influence of heart failure on resting lung volumes in patients with COPD.

    PubMed

    Souza, Aline Soares de; Sperandio, Priscila Abreu; Mazzuco, Adriana; Alencar, Maria Clara; Arbex, Flávio Ferlin; Oliveira, Mayron Faria de; O'Donnell, Denis Eunan; Neder, José Alberto

    2016-01-01

    To evaluate the influence of chronic heart failure (CHF) on resting lung volumes in patients with COPD, i.e., inspiratory fraction-inspiratory capacity (IC)/TLC-and relative inspiratory reserve-[1 - (end-inspiratory lung volume/TLC)]. This was a prospective study involving 56 patients with COPD-24 (23 males/1 female) with COPD+CHF and 32 (28 males/4 females) with COPD only-who, after careful clinical stabilization, underwent spirometry (with forced and slow maneuvers) and whole-body plethysmography. Although FEV1, as well as the FEV1/FVC and FEV1/slow vital capacity ratios, were higher in the COPD+CHF group than in the COPD group, all major "static" volumes-RV, functional residual capacity (FRC), and TLC-were lower in the former group (p < 0.05). There was a greater reduction in FRC than in RV, resulting in the expiratory reserve volume being lower in the COPD+CHF group than in the COPD group. There were relatively proportional reductions in FRC and TLC in the two groups; therefore, IC was also comparable. Consequently, the inspiratory fraction was higher in the COPD+CHF group than in the COPD group (0.42 ± 0.10 vs. 0.36 ± 0.10; p < 0.05). Although the tidal volume/IC ratio was higher in the COPD+CHF group, the relative inspiratory reserve was remarkably similar between the two groups (0.35 ± 0.09 vs. 0.44 ± 0.14; p < 0.05). Despite the restrictive effects of CHF, patients with COPD+CHF have relatively higher inspiratory limits (a greater inspiratory fraction). However, those patients use only a part of those limits, probably in order to avoid critical reductions in inspiratory reserve and increases in elastic recoil. Avaliar a influência da insuficiência cardíaca crônica (ICC) nos volumes pulmonares de repouso em pacientes com DPOC, ou seja, fração inspiratória -capacidade inspiratória (CI)/CPT - e reserva inspiratória relativa - [1 - (volume pulmonar inspiratório final/CPT)]. Após cuidadosa estabilização clínica, 56 pacientes com DPOC (24 alocados no grupo DPOC+ICC; 23 homens/1 mulher) e 32 (28 homens/4 mulheres) com DPOC isolada foram submetidos à espirometria forçada e lenta e pletismografia de corpo inteiro. Os pacientes do grupo DPOC+ICC apresentaram maior VEF1, VEF1/CVF e VEF1/capacidade vital lenta; porém, todos os principais volumes "estáticos" - VR, capacidade residual funcional (CRF) e CPT - foram menores que aqueles do grupo DPOC (p < 0,05). A CRF diminuiu mais do que o VR, determinando assim menor volume de reserva expiratória no grupo DPOC+ICC que no grupo DPOC. Houve redução relativamente proporcional da CRF e da CPT nos dois grupos; logo, a CI também foi similar. Consequentemente, a fração inspiratória no grupo DPOC+ICC foi maior que no grupo DPOC (0,42 ± 0,10 vs. 0,36 ± 0,10; p < 0,05). Embora a razão volume corrente/CI fosse maior no grupo DPOC+ICC, a reserva inspiratória relativa foi notadamente similar entre os grupos (0,35 ± 0,09 vs. 0,44 ± 0,14; p < 0,05). Apesar dos efeitos restritivos da ICC, pacientes com DPOC+ICC apresentam elevações relativas dos limites inspiratórios (maior fração inspiratória). Entretanto, esses pacientes utilizam apenas parte desses limites, com o provável intuito de evitar reduções críticas da reserva inspiratória e maior trabalho elástico.

  8. A computer software system for the generation of global ocean tides including self-gravitation and crustal loading effects

    NASA Technical Reports Server (NTRS)

    Estes, R. H.

    1977-01-01

    A computer software system is described which computes global numerical solutions of the integro-differential Laplace tidal equations, including dissipation terms and ocean loading and self-gravitation effects, for arbitrary diurnal and semidiurnal tidal constituents. The integration algorithm features a successive approximation scheme for the integro-differential system, with time stepping forward differences in the time variable and central differences in spatial variables. Solutions for M2, S2, N2, K2, K1, O1, P1 tidal constituents neglecting the effects of ocean loading and self-gravitation and a converged M2, solution including ocean loading and self-gravitation effects are presented in the form of cotidal and corange maps.

  9. The nature of operating flight loads and their effect on propulsion system structures

    NASA Technical Reports Server (NTRS)

    Dickenson, K. H.; Martin, R. L.

    1981-01-01

    Past diagnostics studies revealed the primary causes of performance deterioration of high by-pass turbofan engines to be flight loads, erosion, and thermal distortion. The various types of airplane loads that are imposed on the engine throughout the lifetime of an airplane are examined. These include flight loads from gusts and maneuvers and ground loads from takeoff, landing, and taxi conditions. Clarification is made in definitions of the airframer's limit and ultimate design loads and the engine manufacturer's operating design loads. Finally, the influence of these loads on the propulsion system structures is discussed.

  10. A torque, tension and stress corrosion evaluation of high strength A286 bolts

    NASA Technical Reports Server (NTRS)

    Montano, J. W.

    1986-01-01

    The problems associated with overtorque applied to the Booster Separation Motor (BSM) Igniter Adapter high strength 200 KSI (1379 Mpa) A286 CRES bolts and the threaded holes of the 7075-T73 aluminum alloy BSM cases are addressed. The evaluation included torque, tensile, and stress corrosion tests incorporating the A286 CRES bolts and the 7075-T73 aluminum alloy BSM cases. The tensile test data includes ultimate tensile load (UTL), Johnson's 2/3 yield load (J2/3YL), proportional limit load (PLL), and total bolt stretch. Torque tension data includes torque, torque induced load, and positive and negative break-away torque. Stress corrosion test data reflect the overtorque and the resulting torque induced loads sustained by the A286 CRES bolts torqued into a 7075-T73 aluminum alloy forged dome with threaded holes. After 60 days of salt fog exposure, the positive and the negative break-away torques, the subsequent mechanical property tensile test results, and the BSM dome threaded hole axial tensile pullout loads are reported.

  11. Plug Load Behavioral Change Demonstration Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Metzger, I.; Kandt, A.; VanGeet, O.

    2011-08-01

    This report documents the methods and results of a plug load study of the Environmental Protection Agency's Region 8 Headquarters in Denver, Colorado, conducted by the National Renewable Energy Laboratory. The study quantified the effect of mechanical and behavioral change approaches on plug load energy reduction and identified effective ways to reduce plug load energy. Load reduction approaches included automated energy management systems and behavioral change strategies.

  12. Load sensing system

    DOEpatents

    Sohns, Carl W.; Nodine, Robert N.; Wallace, Steven Allen

    1999-01-01

    A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast

  13. Studies of the Codeposition of Cobalt Hydroxide and Nickel Hydroxide

    NASA Technical Reports Server (NTRS)

    Ho, C. H.; Murthy, M.; VanZee, J. W.

    1997-01-01

    Topics considered include: chemistry, experimental measurements, planar film model development, impregnation model development, results and conclusion. Also included: effect of cobalt concentration on deposition/loading; effect of current density on loading distribution.

  14. Ceramic Life Prediction Parameters

    DTIC Science & Technology

    1980-05-01

    preferential. A standard creep testing Satec machine with a modified load train assembly was used for tensile stress-rupture testing. The specimen is...to the standard Satec machine head which includes crossed (90°) knife edges. The assembly procedure includes hanging the load train parts from...the Satec head as influenced by gravity. At this point the lower Satec crossarm is lowered to snub the train in this position. The load train

  15. Analysis of potential trade-offs in regulation of disinfection by-products

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cromwell, J.E.; Zhang, X.; Regli, S.

    1992-11-01

    Executive Order 12291 requires the preparation of a Regulatory Impact Analysis (RIA) on all new major federal regulations. The goal of an RIA is to develop and organize information on benefits, costs, and economic impacts so as to clarify trade-offs among alternative regulatory options. This paper outlines explicit methodology for assessing the technical potential for risk-risk tradeoffs. The strategies used to cope with complexities and uncertainties in developing the Disinfection By-Products Regulatory Analysis Model are explained. Results are presented and discussed in light of uncertainties, and in light of the analytical requirements for regulatory impact analysis.

  16. Objective and subjective methods for quantifying training load in wheelchair basketball small-sided games.

    PubMed

    Iturricastillo, Aitor; Granados, Cristina; Los Arcos, Asier; Yanci, Javier

    2017-04-01

    The aim of the present study was to analyse the training load in wheelchair basketball small-sided games and determine the relationship between heart rate (HR)-based training load and perceived exertion (RPE)-based training load methods among small-sided games bouts. HR-based measurements of training load included Edwards' training load and Stagno's training impulses (TRIMP MOD ) while RPE-based training load measurements included cardiopulmonary (session RPEres) and muscular (session RPEmus) values. Data were collected from 12 wheelchair basketball players during five consecutive weeks. The total load for the small-sided games sessions was 67.5 ± 6.7 and 55.3 ± 12.5 AU in HR-based training load (Edwards' training load and TRIMP MOD ), while the RPE-based training loads were 99.3 ± 26.9 (session RPEres) and 100.8 ± 31.2 AU (session RPEmus). Bout-to-bout analysis identified greater session RPEmus in the third [P < 0.05; effect size (ES) = 0.66, moderate] and fourth bouts (P < 0.05; ES = 0.64, moderate) than in the first bout, but other measures did not differ. Mean correlations indicated a trivial and small relationship among HR-based and RPE-based training loads. It is suggested that HR-based and RPE-based training loads provide different information, but these two methods could be complementary because one method could help us to understand the limitations of the other.

  17. A Better ARED Squat

    NASA Technical Reports Server (NTRS)

    Caldwell, E. E.; Newby, N. J.; Ploutz-Snyder, L.

    2014-01-01

    The 0-G ARED squat under loads the legs relative to the 1g ARED squat. In 1g the knee extensor/flexor muscles are primarily engaged due to the body's center of gravity is behind the knees during the motion of the squat. As body weight does not play a sufficient role 0 G, a crewmember's load exposure is limited by the load delivered by ARED through the exercise bar. Prescription loads for lowerbody resistance exercise in microgravity aim to include 1-G exercise bar load in addition to the crewmember's Earth body weight (BW); however, pressure points from the bar and the 1BW increased load at the shoulders translating to higher loads on the back have been a historical limitation for shoulders, requiring a decrease in exercise load at the start of the mission. Analogous to crewmembers, bed rest subjects report limitations of exercising with high loads on the back while performing squats on the horizontal exercise fixture (HEF), a custom exercise device that serves as an analog to 0-G ARED. Improvements for increasing loads on the HEF squat were suggested by distributing total exercise load between the hips and the bar1. The same is recommended for the 0-G ARED squat, with using current equipment on the ISS, which include the T2 running harness and T2 bungees. Quantification of this improvement has been accessed through computational modeling. The purpose of this study is to characterize joint torque during a squat with a distribution in exercise load on the ARED in 0 G. The analysis used existing models from NASA's Digital Astronaut Project. The biomechanics squat model was integrated with the ARED model and T2 bungees. The spring constant for the bungees were derived from ground testing. Forward dynamic simulation was performed for various conditions including anchor point attachments on the footplate of the ARED, bar load, hip load, and gravitational environment. The model confirms joint torques at knees is lower relative to 1G conditions primarily because the load delivery system is just with the exercise bar in 0 G. By distributing partial loads through use of the bungees to the hips joint-torque profiles were altered during a squat and provided options to enhance targeting lower-body loading in aims as for an improved countermeasure.

  18. Application of interleaved flyback micro inverter in a grid connected system

    NASA Astrophysics Data System (ADS)

    Brindha, R.; Ananthichristy, A.; Poornima, P. U.; Madhana, M.; Ashok Rathish, S.; Ragavi, Selvam

    2018-04-01

    The two control strategies CCM and DCM have various effects on the loss distribution and efficiency and thus were studied for the interleaved flyback micro inverter concentrating on the loss analysis under different load conditions. The dominant losses with heavy load include the conduction loss and the transformer loss in case of the interleaved flyback micro inverter; whereas driving of gate loss, the turn-off loss in the transformer core loss and in the powermosfets are included in the dominant losses with light load. A new hybrid control strategy which has the one-phase DCM and two-phase DCM control reduces the dominant losses in order to improving the efficiency based on the load in wide load range is proposed here.

  19. Limits to Open Class Performance?

    NASA Technical Reports Server (NTRS)

    Bowers, Albion H.

    2008-01-01

    This presentation discusses open or unlimited class aircraft performance limitations and design solutions. Limitations in this class of aircraft include slow climbing flight which requires low wing loading, high cruise speed which requires high wing loading, gains in induced or viscous drag alone which result in only half the gain overall and other structural problems (yaw inertia and spins, flutter and static loads integrity). Design solutions include introducing minimum induced drag for a given span (elliptical span load or winglets) and introducing minimum induced drag for a bell shaped span load. It is concluded that open class performance limits (under current rules and technologies) is very close to absolute limits, though some gains remain to be made from unexplored areas and new technologies.

  20. System for controlling a hybrid energy system

    DOEpatents

    Hoff, Brian D.; Akasam, Sivaprasad

    2013-01-29

    A method includes identifying a first operating sequence of a repeated operation of at least one non-traction load. The method also includes determining first and second parameters respectively indicative of a requested energy and output energy of the at least one non-traction load and comparing the determined first and second parameters at a plurality of time increments of the first operating sequence. The method also includes determining a third parameter of the hybrid energy system indicative of energy regenerated from the at least one non-traction load and monitoring the third parameter at the plurality of time increments of the first operating sequence. The method also includes determining at least one of an energy deficiency or an energy surplus associated with the non-traction load of the hybrid energy system and selectively adjusting energy stored within the storage device during at least a portion of a second operating sequence.

  1. Helicopter flight investigation to determine the effects of a closed-circuit TV on performance of a precision sling-load handling task

    NASA Technical Reports Server (NTRS)

    Dicarlo, D. J.; Kelley, H. L.; Spivey, D. L.

    1974-01-01

    Helicopter sling-load operations have been limited during hover and low-speed flight by the degree of precision achieved by the pilot/helicopter/sling-load combination. Previous attempts to improve precision have included stabilization of the load and helicopter and the addition of a pilot station directly facing the load. In these tests, use of a closed-circuit TV as a display that would permit sling-load delivery and placement by the forward-facing pilot was evaluated using a CH-54B helicopter. In all, three test cases were documented, which included the following: (1) forward-facing pilot using the TV display, (2) forward-facing pilot using verbal commands from a load-facing observer, and (3) aft-facing pilot using direct visual cues. The results indicate that a comparable level of performance was achieved for each test case; however, an increase in pilot workload was noted when the TV system was used.

  2. Comparison of computer codes for calculating dynamic loads in wind turbines

    NASA Technical Reports Server (NTRS)

    Spera, D. A.

    1977-01-01

    Seven computer codes for analyzing performance and loads in large, horizontal axis wind turbines were used to calculate blade bending moment loads for two operational conditions of the 100 kW Mod-0 wind turbine. Results were compared with test data on the basis of cyclic loads, peak loads, and harmonic contents. Four of the seven codes include rotor-tower interaction and three were limited to rotor analysis. With a few exceptions, all calculated loads were within 25 percent of nominal test data.

  3. Electrically heated particulate matter filter soot control system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonze, Eugene V.; Paratore, Jr., Michael J.; Bhatia, Garima

    A regeneration system includes a particulate matter (PM) filter with an upstream end for receiving exhaust gas and a downstream end. A control module determines a current soot loading level of the PM filter and compares the current soot loading level to a predetermined soot loading level. The control module permits regeneration of the PM filter when the current soot loading level is less than the predetermined soot loading level.

  4. Observations on associated histopathology with Aggregata octopiana infection (Protista: Apicomplexa) in Octopus vulgaris.

    PubMed

    Gestal, C; Abollo, E; Pascual, S

    2002-06-21

    Gamogony and sporogony of Aggregata octopiana were commonly observed during histological examination of the digestive tract of wild Octopus vulgaris from Ria de Vigo (NW Spain). A. octopiana infected noncuticularized caecum and intestine, and cuticularized oesophagus and crop. Infection was also observed in the gills and in covering mesenterium, mainly of the digestive gland and gonad. Histological and ultrastructural lesions associated with A. octopiana included host cell hypertrophy with nuclear displacement, inflammation, phagocytosis, ulceration and destruction of organ architecture. The possible existence of a malabsorption syndrome in the host is deduced.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stimpson, Shane G.

    In this report, load-follow simulations using VERA-CS with one-way coupling to standalone BISON has been demonstrated including both a single rod with a full cycle of load-follow operations and a quarter-core model with a single month of load-follow.

  6. Low cost electronic ultracapacitor interface technique to provide load leveling of a battery for pulsed load or motor traction drive applications

    DOEpatents

    King, Robert Dean; DeDoncker, Rik Wivina Anna Adelson

    1998-01-01

    A battery load leveling arrangement for an electrically powered system in which battery loading is subject to intermittent high current loading utilizes a passive energy storage device and a diode connected in series with the storage device to conduct current from the storage device to the load when current demand forces a drop in battery voltage. A current limiting circuit is connected in parallel with the diode for recharging the passive energy storage device. The current limiting circuit functions to limit the average magnitude of recharge current supplied to the storage device. Various forms of current limiting circuits are disclosed, including a PTC resistor coupled in parallel with a fixed resistor. The current limit circuit may also include an SCR for switching regenerative braking current to the device when the system is connected to power an electric motor.

  7. A VERSATILE FAMILY OF GALACTIC WIND MODELS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bustard, Chad; Zweibel, Ellen G.; D’Onghia, Elena, E-mail: bustard@wisc.edu

    2016-03-01

    We present a versatile family of model galactic outflows including non-uniform mass and energy source distributions, a gravitational potential from an extended mass source, and radiative losses. The model easily produces steady-state wind solutions for a range of mass-loading factors, energy-loading factors, galaxy mass, and galaxy radius. We find that, with radiative losses included, highly mass-loaded winds must be driven at high central temperatures, whereas low mass-loaded winds can be driven at low temperatures just above the peak of the cooling curve, meaning radiative losses can drastically affect the wind solution even for low mass-loading factors. By including radiative losses,more » we are able to show that subsonic flows can be ignored as a possible mechanism for expelling mass and energy from a galaxy compared to the more efficient transonic solutions. Specifically, the transonic solutions with low mass loading and high energy loading are the most efficient. Our model also produces low-temperature, high-velocity winds that could explain the prevalence of low-temperature material in observed outflows. Finally, we show that our model, unlike the well-known Chevalier and Clegg model, can reproduce the observed linear relationship between wind X-ray luminosity and star formation rate (SFR) over a large range of SFR from 1–1000 M{sub ⊙} yr{sup −1} assuming the wind mass-loading factor is higher for low-mass, and hence, low-SFR galaxies. We also constrain the allowed mass-loading factors that can fit the observed X-ray luminosity versus SFR trend, further suggesting an inverse relationship between mass loading and SFR as explored in advanced numerical simulations.« less

  8. Single Vector Calibration System for Multi-Axis Load Cells and Method for Calibrating a Multi-Axis Load Cell

    NASA Technical Reports Server (NTRS)

    Parker, Peter A. (Inventor)

    2003-01-01

    A single vector calibration system is provided which facilitates the calibration of multi-axis load cells, including wind tunnel force balances. The single vector system provides the capability to calibrate a multi-axis load cell using a single directional load, for example loading solely in the gravitational direction. The system manipulates the load cell in three-dimensional space, while keeping the uni-directional calibration load aligned. The use of a single vector calibration load reduces the set-up time for the multi-axis load combinations needed to generate a complete calibration mathematical model. The system also reduces load application inaccuracies caused by the conventional requirement to generate multiple force vectors. The simplicity of the system reduces calibration time and cost, while simultaneously increasing calibration accuracy.

  9. Liquid salt environment stress-rupture testing

    DOEpatents

    Ren, Weiju; Holcomb, David E.; Muralidharan, Govindarajan; Wilson, Dane F.

    2016-03-22

    Disclosed herein are systems, devices and methods for stress-rupture testing selected materials within a high-temperature liquid salt environment. Exemplary testing systems include a load train for holding a test specimen within a heated inert gas vessel. A thermal break included in the load train can thermally insulate a load cell positioned along the load train within the inert gas vessel. The test specimen can include a cylindrical gage portion having an internal void filled with a molten salt during stress-rupture testing. The gage portion can have an inner surface area to volume ratio of greater than 20 to maximize the corrosive effect of the molten salt on the specimen material during testing. Also disclosed are methods of making a salt ingot for placement within the test specimen.

  10. Near-memory data reorganization engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gokhale, Maya; Lloyd, G. Scott

    A memory subsystem package is provided that has processing logic for data reorganization within the memory subsystem package. The processing logic is adapted to reorganize data stored within the memory subsystem package. In some embodiments, the memory subsystem package includes memory units, a memory interconnect, and a data reorganization engine ("DRE"). The data reorganization engine includes a stream interconnect and DRE units including a control processor and a load-store unit. The control processor is adapted to execute instructions to control a data reorganization. The load-store unit is adapted to process data move commands received from the control processor via themore » stream interconnect for loading data from a load memory address of a memory unit and storing data to a store memory address of a memory unit.« less

  11. Parasitic load control system for exhaust temperature control

    DOEpatents

    Strauser, Aaron D.; Coleman, Gerald N.; Coldren, Dana R.

    2009-04-28

    A parasitic load control system is provided. The system may include an exhaust producing engine and a fuel pumping mechanism configured to pressurize fuel in a pressure chamber. The system may also include an injection valve configured to cause fuel pressure to build within the pressure chamber when in a first position and allow injection of fuel from the pressure chamber into one or more combustion chambers of the engine when in a second position. The system may further include a controller configured to independently regulate the pressure in the pressure chamber and the injection of fuel into the one or more combustion chambers, to increase a load on the fuel pumping mechanism, increasing parasitic load on the engine, thereby increasing a temperature of the exhaust produced by the engine.

  12. Principal Effects of Axial Load on Moment-Distribution Analysis of Rigid Structures

    NASA Technical Reports Server (NTRS)

    James, Benjamin Wylie

    1935-01-01

    This thesis presents the method of moment distribution modified to include the effect of axial load upon the bending moments. This modification makes it possible to analyze accurately complex structures, such as rigid fuselage trusses, that heretofore had to be analyzed by approximate formulas and empirical rules. The method is simple enough to be practicable even for complex structures, and it gives a means of analysis for continuous beams that is simpler than the extended three-moment equation now in common use. When the effect of axial load is included, it is found that the basic principles of moment distribution remain unchanged, the only difference being that the factors used, instead of being constants for a given member, become functions of the axial load. Formulas have been developed for these factors, and curves plotted so that their applications requires no more work than moment distribution without axial load. Simple problems have been included to illustrate the use of the curves.

  13. Vínculos sobre um modelo de quartessência de Chaplygin usando observações do satélite chandra da fração de massa de gás em aglomerados de galáxias

    NASA Astrophysics Data System (ADS)

    de Souza, R. S.

    2003-08-01

    Observações de Supernovas do tipo Ia mostram que a expansão do Universo está acelerando. Segundo as equações de Einstein uma componente com pressão negativa (energia escura) é necessária para explicar a aceleração cósmica. Além da energia escura é usualmente admitido que no Universo há também uma matéria exótica com pressão zero, que é chamada de matéria escura. Essa componente possui um papel fundamental na formação de estruturas no Universo. Recentemente tem se explorado a possibilidade de que matéria e energia escura poderiam ser unificadas através de uma única componente, que tem sido denominada de quartessência. Um exemplo de fluido com essas características é o Gás de Chaplygin Generalizado, que possui uma equação de estado da forma p = -A/ra. Inicialmente consideramos o caso especial a = 1 (gás de Chaplygin) e vinculamos parâmetros do modelo utilizando observações em raios-X do satélite Chandra da fração de massa de gás em aglomerados de galáxias. Uma comparação dos vínculos obtidos com esse teste com outros testes, tais como supernovas e idade do Universo, mostra que esse teste é bastante restritivo. Exibiremos ainda resultados para o caso em que a curvatura é nula e o parâmetro a está compreendido no intervalo -1 < a 1.

  14. Radioimmunoassay and tandem mass spectrometry measurement of bedtime salivary cortisol levels: a comparison of assays to establish hypercortisolism.

    PubMed

    Baid, Smita K; Sinaii, Ninet; Wade, Matt; Rubino, Domenica; Nieman, Lynnette K

    2007-08-01

    Although bedtime salivary cortisol measurement has been proposed as the optimal screening test for the diagnosis of Cushing's syndrome, its performance using commercially available assays has not been widely evaluated. Our objective was to compare RIA and tandem mass spectrometry (LC-MS/MS) measurement of salivary cortisol in obese subjects and healthy volunteers. We conducted a cross-sectional prospective study of outpatients. We studied 261 obese subjects (186 female) with at least two additional features of Cushing's syndrome and 60 healthy volunteers (30 female). Subjects provided split bedtime salivary samples for cortisol measurement by commercially available RIA and LC-MS/MS. Results were considered normal or abnormal based on the laboratory reference range. Subjects with abnormal results underwent evaluation for Cushing's syndrome. In paired samples, RIA gave a lower specificity than LC-MS/MS in obese subjects (86 vs. 94%, P = 0.008) but not healthy volunteers (86 vs. 82%, P = 0.71). Among subjects with at least one abnormal result, both values were abnormal in 44% (confidence interval 26-62%) of obese and 75% (confidence interval 33-96%) of healthy volunteers. In obese subjects, salivary cortisol concentrations were less than 4.0 to 643 ng/dl (<0.11-17.7 nmol/liter; normal, < or =100 ng/dl, 2.80 nmol/liter) by LC-MS/MS and less than 50 to 2800 ng/dl (1.4-77.3 nmol/liter; normal, < or =170 ng/dl, 4.7 nmol/liter) by RIA. Cushing's syndrome was not diagnosed in any subject. Salivary cortisol levels should not be used as the sole test to diagnose Cushing's syndrome if laboratory-provided reference ranges are used for diagnostic interpretation.

  15. Statistical analysis of radioimmunoassay. In comparison with bioassay (in Japanese)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakano, R.

    1973-01-01

    Using the data of RIA (radioimmunoassay), statistical procedures for dealing with two problems of the linearization of dose response curve and calculation of relative potency were described. There were three methods for linearization of dose response curve of RIA. In each method, the following parameters were shown on the horizontal and vertical axis: dose x, (B/T)/sup -1/; c/x + c, B/T (C: dose which makes B/T 50%); log x, logit B/T. Among them, the last method seems to be most practical. The statistical procedures for bioassay were employed for calculating the relative potency of unknown samples compared to the standardmore » samples from dose response curves of standand and unknown samples using regression coefficient. It is desirable that relative potency is calculated by plotting more than 5 points in the standard curve and plotting more than 2 points in unknow samples. For examining the statistical limit of precision of measuremert, LH activity of gonadotropin in urine was measured and relative potency, precision coefficient and the upper and lower limits of relative potency at 95% confidence limit were calculated. On the other hand, bioassay (by the ovarian ascorbic acid reduction method and anteriol lobe of prostate weighing method) was done in the same samples, and the precision was compared with that of RIA. In these examinations, the upper and lower limits of the relative potency at 95% confidence limit were near each other, while in bioassay, a considerable difference was observed between the upper and lower limits. The necessity of standardization and systematization of the statistical procedures for increasing the precision of RIA was pointed out. (JA)« less

  16. Determining Vitamin D Status: A Comparison between Commercially Available Assays

    PubMed Central

    Snellman, Greta; Melhus, Håkan; Gedeborg, Rolf; Byberg, Liisa; Berglund, Lars; Wernroth, Lisa; Michaëlsson, Karl

    2010-01-01

    Background Vitamin D is not only important for bone health but can also affect the development of several non-bone diseases. The definition of vitamin D insufficiency by serum levels of 25-hydroxyvitamin D depends on the clinical outcome but might also be a consequence of analytical methods used for the definition. Although numerous 25-hydroxyvitamin D assays are available, their comparability is uncertain. We therefore aim to investigate the precision, accuracy and clinical consequences of differences in performance between three common commercially available assays. Methodology/Principal Findings Serum 25-hydroxyvitamin D levels from 204 twins from the Swedish Twin Registry were determined with high-pressure liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (HPLC-APCI-MS), a radioimmunoassay (RIA) and a chemiluminescent immunoassay (CLIA). High inter-assay disagreement was found. Mean 25-hydroxyvitamin D levels were highest for the HPLC-APCI-MS technique (85 nmol/L, 95% CI 81–89), intermediate for RIA (70 nmol/L, 95% CI 66–74) and lowest with CLIA (60 nmol/L, 95% CI 56–64). Using a 50-nmol/L cut-off, 8% of the subjects were insufficient using HPLC-APCI-MS, 22% with RIA and 43% by CLIA. Because of the heritable component of 25-hydroxyvitamin D status, the accuracy of each method could indirectly be assessed by comparison of within-twin pair correlations. The strongest correlation was found for HPLC-APCI-MS (r = 0.7), intermediate for RIA (r = 0.5) and lowest for CLIA (r = 0.4). Regression analyses between the methods revealed a non-uniform variance (p<0.0001) depending on level of 25-hydroxyvitamin D. Conclusions/Significance There are substantial inter-assay differences in performance. The most valid method was HPLC-APCI-MS. Calibration between 25-hydroxyvitamin D assays is intricate. PMID:20644628

  17. A comparison of five sampling techniques to estimate surface fuel loading in montane forests

    Treesearch

    Pamela G. Sikkink; Robert E. Keane

    2008-01-01

    Designing a fuel-sampling program that accurately and efficiently assesses fuel load at relevant spatial scales requires knowledge of each sample method's strengths and weaknesses.We obtained loading values for six fuel components using five fuel load sampling techniques at five locations in western Montana, USA. The techniques included fixed-area plots, planar...

  18. Dynamic load environment of bridge-mounted sign support structures : research implementation plan.

    DOT National Transportation Integrated Search

    2005-09-01

    Welded aluminum highway sign support trusses must withstand in-service dynamic loads, which largely : constitute the fatigue environment. Sources of these dynamic loads include the natural wind and seismic : environment, the artificial wind environme...

  19. Behavior of sandwich panels subjected to bending fatigue, axial compression loading and in-plane bending

    NASA Astrophysics Data System (ADS)

    Mathieson, Haley Aaron

    This thesis investigates experimentally and analytically the structural performance of sandwich panels composed of glass fibre reinforced polymer (GFRP) skins and a soft polyurethane foam core, with or without thin GFRP ribs connecting skins. The study includes three main components: (a) out-of-plane bending fatigue, (b) axial compression loading, and (c) in-plane bending of sandwich beams. Fatigue studies included 28 specimens and looked into establishing service life (S-N) curves of sandwich panels without ribs, governed by soft core shear failure and also ribbed panels governed by failure at the rib-skin junction. Additionally, the study compared fatigue life curves of sandwich panels loaded under fully reversed bending conditions (R=-1) with panels cyclically loaded in one direction only (R=0) and established the stiffness degradation characteristics throughout their fatigue life. Mathematical models expressing fatigue life and stiffness degradation curves were calibrated and expanded forms for various loading ratios were developed. Approximate fatigue thresholds of 37% and 23% were determined for non-ribbed panels loaded at R=0 and -1, respectively. Digital imaging techniques showed significant shear contribution significantly (90%) to deflections if no ribs used. Axial loading work included 51 specimens and examined the behavior of panels of various lengths (slenderness ratios), skin thicknesses, and also panels of similar length with various rib configurations. Observed failure modes governing were global buckling, skin wrinkling or skin crushing. In-plane bending involved testing 18 sandwich beams of various shear span-to-depth ratios and skin thicknesses, which failed by skin wrinkling at the compression side. The analytical modeling components of axially loaded panels include; a simple design-oriented analytical failure model and a robust non-linear model capable of predicting the full load-displacement response of axially loaded slender sandwich panels, accounting for P-Delta effects, inherent out-of-straightness profile of any shape at initial conditions, and the excessive shear deformation of soft core and its effect on buckling capacity. Another model was developed to predict the load-deflection response and failure modes of in-plane loaded sandwich beams. After successful verification of the models using experimental results, comprehensive parametric studies were carried out using these models to cover parameters beyond the limitations of the experimental program.

  20. Using squat repetition maximum testing to determine hamstring resistance training exercise loads.

    PubMed

    Ebben, William P; Long, Nicholas J; Pawlowski, Zach D; Chmielewski, Lauren M; Clewien, Rustin W; Jensen, Randall L

    2010-02-01

    The purpose of this study was to determine whether there is a linear relationship between the squat and a variety of hamstring resistance training exercises, and whether this relationship differs on the basis of sex. This study also sought to create prediction equations for the determination of hamstring exercise load based on the squat load. Repetition maximums of the squat, as well as 4 common hamstring resistance training exercises including the seated leg curl, stiff leg dead lift, single leg dead lift, and good morning exercise, were determined for each subject. Subjects included 21 men and 13 women collegiate athletes. Data were evaluated using linear regression analysis to predict hamstring exercise loads from 6 repetition maximum squat data. Results of the analysis of all subjects indicated that squat load was a significant predictor of loads for each of the hamstring exercises. However, separate analysis of women revealed that squat load was not a significant predictor of loads for any of the hamstring exercises. Analysis of the men revealed that squat was a significant predictor of load for the seated leg curl (R = 0.58, p < 0.001), stiff leg dead lift (R = 0.82, p < 0.001), single leg stiff leg dead lift (R = 0.80, p < 0.001), and good morning (R = 0.79, p < 0.001) exercises. On the basis of the analysis of the men, the following prediction equations were devised for each exercise: (1) seated leg curl load = squat load (0.186) + 10.935 kg, (2) stiff leg deadlift load = squat load (1.133) - 86.331 kg, (3) single leg stiff leg deadlift load = squat load (0.443) - 3.425 kg, and (4) good morning load = squat load (0.961) - 105.505 kg. Thus, results from testing core exercises such as the squat can provide useful data for the assignment of loads for assistance exercises.

  1. Graphical Modeling of Shipboard Electric Power Distribution Systems

    DTIC Science & Technology

    1993-12-01

    examined. A means of modeling a load for a synchronous generator is then shown which accurately interrelates the loading of the generator and the...frequency and voltage output of the machine. This load is then connected to the synchronous generator and two different scenarios are examined including a...examined. A means of modeling a load for a synchronous generator is then shown which accurately interrelates the loading of the generator and tht

  2. Heat sink structural design concepts for a hypersonic research airplane

    NASA Technical Reports Server (NTRS)

    Taylor, A. H.; Jackson, L. R.

    1977-01-01

    Hypersonic research aircraft design requires careful consideration of thermal stresses. This paper relates some of the problems in a heat sink structural design that can be avoided by appropriate selection of design options including material selection, design concepts, and load paths. Data on several thermal loading conditions are presented on various conventional designs including bulkheads, longerons, fittings, and frames. Results indicate that conventional designs are inadequate and that acceptable designs are possible by incorporating innovative design practices. These include nonintegral pressure compartments, ball-jointed links to distribute applied loads without restraining the thermal expansion, and material selections based on thermal compatibility.

  3. ASME AG-1 Section FC Qualified HEPA Filters; a Particle Loading Comparison - 13435

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stillo, Andrew; Ricketts, Craig I.

    High Efficiency Particulate Air (HEPA) Filters used to protect personnel, the public and the environment from airborne radioactive materials are designed, manufactured and qualified in accordance with ASME AG-1 Code section FC (HEPA Filters) [1]. The qualification process requires that filters manufactured in accordance with this ASME AG-1 code section must meet several performance requirements. These requirements include performance specifications for resistance to airflow, aerosol penetration, resistance to rough handling, resistance to pressure (includes high humidity and water droplet exposure), resistance to heated air, spot flame resistance and a visual/dimensional inspection. None of these requirements evaluate the particle loading capacitymore » of a HEPA filter design. Concerns, over the particle loading capacity, of the different designs included within the ASME AG-1 section FC code[1], have been voiced in the recent past. Additionally, the ability of a filter to maintain its integrity, if subjected to severe operating conditions such as elevated relative humidity, fog conditions or elevated temperature, after loading in use over long service intervals is also a major concern. Although currently qualified HEPA filter media are likely to have similar loading characteristics when evaluated independently, filter pleat geometry can have a significant impact on the in-situ particle loading capacity of filter packs. Aerosol particle characteristics, such as size and composition, may also have a significant impact on filter loading capacity. Test results comparing filter loading capacities for three different aerosol particles and three different filter pack configurations are reviewed. The information presented represents an empirical performance comparison among the filter designs tested. The results may serve as a basis for further discussion toward the possible development of a particle loading test to be included in the qualification requirements of ASME AG-1 Code sections FC and FK[1]. (authors)« less

  4. Designing divertor targets for uniform power load

    NASA Astrophysics Data System (ADS)

    Dekeyser, W.; Reiter, D.; Baelmans, M.

    2015-08-01

    Divertor design for next step fusion reactors heavily relies on 2D edge plasma modeling with codes as e.g. B2-EIRENE. While these codes are typically used in a design-by-analysis approach, in previous work we have shown that divertor design can alternatively be posed as a mathematical optimization problem, and solved very efficiently using adjoint methods adapted from computational aerodynamics. This approach has been applied successfully to divertor target shape design for more uniform power load. In this paper, the concept is further extended to include all contributions to the target power load, with particular focus on radiation. In a simplified test problem, we show the potential benefits of fully including the radiation load in the design cycle as compared to only assessing this load in a post-processing step.

  5. Loading and conjugating cavity biostructures

    DOEpatents

    Hainfeld, J.F.

    1997-11-25

    Methods for the preparation and use of a biological delivery system are disclosed. The method of preparation includes the loading of a non-biological material into a biostructure having a load-bearing structure. The method also includes the removal of some of the biostructure`s contents and the loading of a non-biological material into the biostructure. The biostructure is biologically compatible with the host, and preferably is derived from the host, the host`s species or a related species. The loaded biostructure is used directly, or it can be targeted to specific cells, tissues and/or organs within a host. The targeted biostructure can be used to deliver the non-biological material to a specified tissue, organ or cell within a host for diagnostic, therapeutic or other purposes. 11 figs.

  6. Loading and conjugating cavity biostructures

    DOEpatents

    Hainfeld, J.F.

    1995-08-22

    Methods for the preparation and use of a biological delivery system are disclosed. The method of preparation includes the loading of a non-biological material into a biostructure having a load-bearing structure. The method also includes the removal of some of the biostructure`s contents and the loading of a non-biological material into the biostructure. The biostructure is biologically compatible with the host, and preferably is derived from the host, the host`s species or a related species. The loaded biostructure is used directly, or it can be targeted to specific cells, tissues and/or organs within a host. The targeted biostructure can be used to deliver the non-biological material to a specified tissue, organ or cell within a host for diagnostic, therapeutic or other purposes. 11 figs.

  7. Electric power distribution and load transfer system

    NASA Technical Reports Server (NTRS)

    Bradford, Michael P. (Inventor); Parkinson, Gerald W. (Inventor); Grant, Ross M. (Inventor)

    1987-01-01

    A power distribution system includes a plurality of power sources and load transfer units including transistors and diodes connected in series and leading to a common power output, each of the transistors being controller switchable subject to voltage levels of the respective input and output sides of said transistors, and the voltage and current level of said common power output. The system is part of an interconnection scheme in which all but one of the power sources is connected to a single load transfer unit, enabling the survival of at least a single power source with the failure of one of the load transfer units.

  8. Electric power distribution and load transfer system

    NASA Technical Reports Server (NTRS)

    Bradford, Michael P. (Inventor); Parkinson, Gerald W. (Inventor); Grant, Ross M. (Inventor)

    1989-01-01

    A power distribution system includes a plurality of power sources and load transfer units including transistors and diodes connected in series and leading to a common power output, each of the transistors being controller switchable subject to voltage levels of the respective input and output sides of said transistors, and the voltage and current level of said common power output. The system is part of an interconnection scheme in which all but one of the power sources is connected to a single load transfer unit, enabling the survival of at least a single power source with the failure of one of the load transfer units.

  9. Load research manual. Volume 1. Load research procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. In Volumes 1 and 2, procedures are suggested for determining data requirements for load research, establishing the size and customer composition of a load survey sample, selecting and using equipment to record customer electricity usage, processing data tapes from the recording equipment, and analyzing the data. Statistical techniques used in customer sampling are discussedmore » in detail. The costs of load research also are estimated, and ongoing load research programs at three utilities are described. The manual includes guides to load research literature and glossaries of load research and statistical terms.« less

  10. Metallic Thermal Protection System Technology Development: Concepts, Requirements and Assessment Overview

    NASA Technical Reports Server (NTRS)

    Dorsey, John T.; Poteet, Carl C.; Chen, Roger R.; Wurster, Kathryn E.

    2002-01-01

    A technology development program was conducted to evolve an earlier metallic thermal protection system (TPS) panel design, with the goals of: improving operations features, increasing adaptability (ease of attaching to a variety of tank shapes and structural concepts), and reducing weight. The resulting Adaptable Robust Metallic Operable Reusable (ARMOR) TPS system incorporates a high degree of design flexibility (allowing weight and operability to be traded and balanced) and can also be easily integrated with a large variety of tank shapes, airframe structural arrangements and airframe structure/material concepts. An initial attempt has been made to establish a set of performance based TPS design requirements. A set of general (FARtype) requirements have been proposed, focusing on defining categories that must be included for a comprehensive design. Load cases required for TPS design must reflect the full flight envelope, including a comprehensive set of limit loads, However, including additional loads. such as ascent abort trajectories, as ultimate load cases, and on-orbit debris/micro-meteoroid hypervelocity impact, as one of the discrete -source -damage load cases, will have a significant impact on system design and resulting performance, reliability and operability. Although these load cases have not been established, they are of paramount importance for reusable vehicles, and until properly included, all sizing results and assessments of reliability and operability must be considered optimistic at a minimum.

  11. Control circuit maintains unity power factor of reactive load

    NASA Technical Reports Server (NTRS)

    Kramer, M.; Martinage, L. H.

    1966-01-01

    Circuit including feedback control elements automatically corrects the power factor of a reactive load. It maintains power supply efficiency where negative load reactance changes and varies by providing corrective error signals to the control windings of a power supply transformer.

  12. Shape memory-based actuators and release mechanisms therefrom

    NASA Technical Reports Server (NTRS)

    Vaidyanathan, Rajan (Inventor); Snyder, Daniel W. (Inventor); Schoenwald, David K. (Inventor); Lam, Nhin S. (Inventor); Watson, Daniel S. (Inventor); Krishnan, Vinu B. (Inventor); Noebe, Ronald D. (Inventor)

    2012-01-01

    SM-based actuators (110) and release mechanisms (100) therefrom and systems (500) including one or more release mechanisms (100). The actuators (110) comprise a SM member (118) and a deformable member (140) mechanically coupled to the SM member (118) which deforms upon a shape change of the SM member triggered by a phase transition of the SM member. A retaining element (160) is mechanically coupled to the deformable member (140), wherein the retaining element (160) moves upon the shape change. Release mechanism (100) include an actuator, a rotatable mechanism (120) including at least one restraining feature (178) for restraining rotational movement of the retaining element (160) before the shape change, and at least one spring (315) that provides at least one locked spring-loaded position when the retaining element is in the restraining feature and at least one released position that is reached when the retaining element is in a position beyond the restraining feature (178). The rotatable mechanism (120) includes at least one load-bearing protrusion (310). A hitch (400) is for mechanically coupling to the load, wherein the hitch is supported on the load bearing protrusion (310) when the rotatable mechanism is in the locked spring-loaded position.

  13. The relationship between loads and power of a rotor and an actuator disc

    NASA Astrophysics Data System (ADS)

    van Kuik, Gijs A. M.

    2014-12-01

    Most state of the art rotor design methods are based on the actuator disc theory developed about one century ago. The actuator disc is an axisymmetric permeable surface carrying a load that represents the load on a real rotor with a finite number of blades N. However, the mathematics of the transition from a real rotor load to an axisymmetrically loaded disc is not yet presented in literature. By formulating an actuator disc equation of motion in which the Bernoulli constant H is expressed in kinematical terms, a comparison of the power conversion and load on the disc and rotor is possible. For both the converted power is expressed as a change of angular momentum times rotational speed. The limits for N → ∞ while the chord c → 0, the rotational speed Ω → ∞, the load F becoming uniform by ∂F/∂r → 0 and the thickness epsilon → 0 confirm that the classical disc represents the rotor with an infinite number of blades. Furthermore, the expressions for the blade load are compared to the expressions in current design and analysis tools. The latter do not include the load on chord-wise vorticity. Including this is expected to give a better modelling of the tip and root flow.

  14. Stereo photo series for quantifying natural fuels. Volume XII: Post-hurricane fuels in forests of the Southeast United States.

    Treesearch

    Robert E. Vihnanek; Cameron S. Balog; Clinton S. Wright; Roger D. Ottmar; Jeffrey W. Kelly

    2009-01-01

    Two series of single and stereo photographs display a range of natural conditions and fuel loadings in post-hurricane forests in the southeastern United States. Each group of photos includes inventory information summarizing vegetation composition, structure and loading, woody material loading and density by size class, forest floor loading, and various site...

  15. 40 CFR 201.23 - Test site, weather conditions and background noise criteria for measurement at a 30 meter (100...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... rail car operations and locomotive load cell test stands. 201.23 Section 201.23 Protection of... locomotive and rail car operations and locomotive load cell test stands. (a) The standard test site shall be... contribution from the operation of the load cell, if any, including load cell contribution during test. (h...

  16. Strain-gage bridge calibration and flight loads measurements on a low-aspect-ratio thin wing

    NASA Technical Reports Server (NTRS)

    Peele, E. L.; Eckstrom, C. V.

    1975-01-01

    Strain-gage bridges were used to make in-flight measurements of bending moment, shear, and torque loads on a low-aspect-ratio, thin, swept wing having a full depth honeycomb sandwich type structure. Standard regression analysis techniques were employed in the calibration of the strain bridges. Comparison of the measured loads with theoretical loads are included.

  17. Cable load sensing device

    DOEpatents

    Beus, Michael J.; McCoy, William G.

    1998-01-01

    Apparatus for sensing the magnitude of a load on a cable as the cable is employed to support the load includes a beam structure clamped to the cable so that a length of the cable lies along the beam structure. A spacer associated with the beam structure forces a slight curvature in a portion of the length of cable under a cable "no-load" condition so that the portion of the length of cable is spaced from the beam structure to define a cable curved portion. A strain gauge circuit including strain gauges is secured to the beam structure by welding. As the cable is employed to support a load the load causes the cable curved portion to exert a force normal to the cable through the spacer and on the beam structure to deform the beam structure as the cable curved portion attempts to straighten under the load. As this deformation takes place, the resistance of the strain gauges is set to a value proportional to the magnitude of the normal strain on the beam structure during such deformation. The magnitude of the normal strain is manipulated in a control device to generate a value equal to the magnitude or weight of the load supported by the cable.

  18. An alternative method for centrifugal compressor loading factor modelling

    NASA Astrophysics Data System (ADS)

    Galerkin, Y.; Drozdov, A.; Rekstin, A.; Soldatova, K.

    2017-08-01

    The loading factor at design point is calculated by one or other empirical formula in classical design methods. Performance modelling as a whole is out of consideration. Test data of compressor stages demonstrates that loading factor versus flow coefficient at the impeller exit has a linear character independent of compressibility. Known Universal Modelling Method exploits this fact. Two points define the function - loading factor at design point and at zero flow rate. The proper formulae include empirical coefficients. A good modelling result is possible if the choice of coefficients is based on experience and close analogs. Earlier Y. Galerkin and K. Soldatova had proposed to define loading factor performance by the angle of its inclination to the ordinate axis and by the loading factor at zero flow rate. Simple and definite equations with four geometry parameters were proposed for loading factor performance calculated for inviscid flow. The authors of this publication have studied the test performance of thirteen stages of different types. The equations are proposed with universal empirical coefficients. The calculation error lies in the range of plus to minus 1,5%. The alternative model of a loading factor performance modelling is included in new versions of the Universal Modelling Method.

  19. Transient Three-Dimensional Analysis of Side Load in Liquid Rocket Engine Nozzles

    NASA Technical Reports Server (NTRS)

    Wang, Ten-See

    2004-01-01

    Three-dimensional numerical investigations on the nozzle start-up side load physics were performed. The objective of this study is to identify the three-dimensional side load physics and to compute the associated aerodynamic side load using an anchored computational methodology. The computational methodology is based on an unstructured-grid, and pressure-based computational fluid dynamics formulation, and a simulated inlet condition based on a system calculation. Finite-rate chemistry was used throughout the study so that combustion effect is always included, and the effect of wall cooling on side load physics is studied. The side load physics captured include the afterburning wave, transition from free- shock to restricted-shock separation, and lip Lambda shock oscillation. With the adiabatic nozzle, free-shock separation reappears after the transition from free-shock separation to restricted-shock separation, and the subsequent flow pattern of the simultaneous free-shock and restricted-shock separations creates a very asymmetric Mach disk flow. With the cooled nozzle, the more symmetric restricted-shock separation persisted throughout the start-up transient after the transition, leading to an overall lower side load than that of the adiabatic nozzle. The tepee structures corresponding to the maximum side load were addressed.

  20. Enhanced Actuator Line Simulation of a Wind Turbine by including the Conservative Load at the Blade Tip

    NASA Astrophysics Data System (ADS)

    Herraez, Ivan; Micallef, Daniel; van Kuik, Gijs A. M.; Peinke, Joachim

    2015-11-01

    At the tip of wind turbine blades, the radial bound circulation is transformed into chordwise circulation just before being released as trailing vorticity, giving rise to the tip vortex. The force acting on the chordwise circulation contains a radial and a normal component with respect to the blade axis. This load does not contribute to the torque, so it is a conservative load. Due to this, it is disregarded in the engineering tools used for the design of wind turbines. However, as we demonstrated in a previous work, the conservative load might influence the trajectory of the tip vortex. In order to see how this affects the blade loads, in this research we perform large eddy simulations with an actuator line model where the conservative load has been included. The conservative load reduces the angle of attack in the tip region as a consequence of the modified tip vortex trajectory. This has a negative influence on the lift and the power output. We conclude that the accuracy of engineering design tools of wind turbines can be improved if the conservative load acting at the tip is considered.

  1. Composite load spectra for select space propulsion structural components

    NASA Technical Reports Server (NTRS)

    Newell, J. F.; Kurth, R. E.; Ho, H.

    1986-01-01

    A multiyear program is performed with the objective to develop generic load models with multiple levels of progressive sophistication to simulate the composite (combined) load spectra that are induced in space propulsion system components, representative of Space Shuttle Main Engines (SSME), such as transfer ducts, turbine blades, and liquid oxygen (LOX) posts. Progress of the first year's effort includes completion of a sufficient portion of each task -- probabilistic models, code development, validation, and an initial operational code. This code has from its inception an expert system philosophy that could be added to throughout the program and in the future. The initial operational code is only applicable to turbine blade type loadings. The probabilistic model included in the operational code has fitting routines for loads that utilize a modified Discrete Probabilistic Distribution termed RASCAL, a barrier crossing method and a Monte Carlo method. An initial load model was developed by Battelle that is currently used for the slowly varying duty cycle type loading. The intent is to use the model and related codes essentially in the current form for all loads that are based on measured or calculated data that have followed a slowly varying profile.

  2. [Revista Brasileira de História da Medicina, a pioneer in medical historiography].

    PubMed

    Mendonça, Amanda; Nicolini, Gabriel Baptista

    2007-01-01

    I(It? This?) presents the general characteristics of the Revista Brasileira de História da Medicina, which contributed for the emergence of the field of medicine history in Brazil by inciting bibliographic production on the subject. The purpose of our analysis is to foster research on the history of medicine and of the sciences. From the description of the editorial aspects of the journal one can have an idea of how the research field was organized between 1940 and 1960. The periodical also allows for an overview of the exchange occurring between Brazilian and foreign historian physicians at that time.

  3. Aquisição fonológica do português brasileiro por crianças ouvintes bilíngues bimodais e surdas usuárias de implante coclear

    PubMed Central

    Cruz, Carina Rebello; Finger, Ingrid

    2014-01-01

    Resumo O presente estudo investiga a aquisição fonológica do Português Brasileiro (PB) por 24 crianças ouvintes bilíngues bimodais, com acesso irrestrito à Língua Brasileira de Sinais (Libras), e por 6 crianças surdas que utilizam implante coclear (IC), com acesso restrito ou irrestrito à Libras. Para a avaliação do sistema fonológico das crianças em PB, foi utilizada a Parte A, Prova de Nomeação, do ABFW – Teste de Linguagem Infantil (ANDRADE et al. 2004). Os resultados revelaram que as crianças ouvintes bilíngues bimodais e a criança surda usuária de IC com acesso irrestrito à Libras apresentaram processo de aquisição fonológica esperada (normal) para a sua faixa etária. Considera-se que a aquisição precoce e o acesso irrestrito à Libras podem ter sido determinantes para o desempenho dessas crianças no teste oral utilizado. PMID:25506105

  4. Comparison of results for morphine urinalyses by radioimmunoassay and thin-layer chromatography in a narcotic clinic setting.

    PubMed

    Kokoski, R J; Jain, M

    1975-03-01

    Radioimmunoassay (RIA) and thin-layer chromatography (TLC) were compared for morphine detection in an actual narcotic clinic setting. A choice of urines from all those screened by TLC allowed a critical comparison as to actual use or non-use of narcotic drugs, rather than a sampling at random in which the question of possible false positives or negatives cannot be conclusively answered. Although RIA is more sensitive than TLC, its advantage is apparent only in those cases where urine specimens are difficult to obtain frequently regularly or where the use of morphine is suspected by the positive identification of quinine in urine that was morphine-negative by TLC. In a selected group of negative and positive specimens chosen without conscious bias, the two methods gave consistently similar results, indicating that the modified TLC method provided a few or no false positives or negatives if the negatives were from those cases that were not positive anytime up to 3-4 days before urine collection. We conclude that RIA can be of significant value as a supplement to a TLC screening program, without sacrificing the many advantages that TLC has to offer.

  5. Fundamental metallurgical aspects of axial splitting in zircaloy cladding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chung, H. M.

    Fundamental metallurgical aspects of axial splitting in irradiated Zircaloy cladding have been investigated by microstructural characterization and analytical modeling, with emphasis on application of the results to understand high-burnup fuel failure under RIA situations. Optical microscopy, SEM, and TEM were conducted on BWR and PWR fuel cladding tubes that were irradiated to fluence levels of 3.3 x 10{sup 21} n cm{sup {minus}2} to 5.9 x 10{sup 21} n cm{sup {minus}2} (E > 1 MeV) and tested in hot cell at 292--325 C in Ar. The morphology, distribution, and habit planes of macroscopic and microscopic hydrides in as-irradiated and posttest claddingmore » were determined by stereo-TEM. The type and magnitude of the residual stress produced in association with oxide-layer growth and dense hydride precipitation, and several synergistic factors that strongly influence axial-splitting behavior were analyzed. The results of the microstructural characterization and stress analyses were then correlated with axial-splitting behavior of high-burnup PWR cladding reported for simulated-RIA conditions. The effects of key test procedures and their implications for the interpretation of RIA test results are discussed.« less

  6. On the predictability of extreme events in records with linear and nonlinear long-range memory: Efficiency and noise robustness

    NASA Astrophysics Data System (ADS)

    Bogachev, Mikhail I.; Bunde, Armin

    2011-06-01

    We study the predictability of extreme events in records with linear and nonlinear long-range memory in the presence of additive white noise using two different approaches: (i) the precursory pattern recognition technique (PRT) that exploits solely the information about short-term precursors, and (ii) the return interval approach (RIA) that exploits long-range memory incorporated in the elapsed time after the last extreme event. We find that the PRT always performs better when only linear memory is present. In the presence of nonlinear memory, both methods demonstrate comparable efficiency in the absence of white noise. When additional white noise is present in the record (which is the case in most observational records), the efficiency of the PRT decreases monotonously with increasing noise level. In contrast, the RIA shows an abrupt transition between a phase of low level noise where the prediction is as good as in the absence of noise, and a phase of high level noise where the prediction becomes poor. In the phase of low and intermediate noise the RIA predicts considerably better than the PRT, which explains our recent findings in physiological and financial records.

  7. [Prenatal patient cards and quality of prenatal care in public health services in Greater Metropolitan Vitória, Espírito Santo State, Brazil].

    PubMed

    Santos Neto, Edson Theodoro dos; Oliveira, Adauto Emmerich; Zandonade, Eliana; Gama, Silvana Granado Nogueira da; Leal, Maria do Carmo

    2012-09-01

    This study aimed to assess the completeness of prenatal care information on the patients' prenatal care cards, according to coverage by various public health services: Family Health Strategy (FHS), Community-Based Health Workers' Program (CBHWP), and traditional Primary Care Units (PCU) in Greater Metropolitan Vitória, Espírito Santo State, Brazil. In a cross-sectional study, 1,006 prenatal cards were randomly selected from postpartum women at maternity hospitals in the metropolitan area. Completeness of the cards was assessed according to the criteria proposed by Romero & Cunha, which measure the quality on a scale from excellent (< 5% incomplete cards) to very bad (> 50% incomplete cards). In general, completion of information on the cards was bad (> 20% incomplete), but cards were filled out better in the FHS than in the CBHWP and PCU, especially for tetanus vaccination (p = 0.016) and gestational weight (p = 0.039). In conclusion, the quality of prenatal care in the public health system in Greater Metropolitan Vitória fails to meet the Brazilian national guidelines for maternal and child health.

  8. Characterization studies of prototype ISOL targets for the RIA

    NASA Astrophysics Data System (ADS)

    Greene, John P.; Burtseva, Tatiana; Neubauer, Janelle; Nolen, Jerry A.; Villari, Antonio C. C.; Gomes, Itacil C.

    2005-12-01

    Targets employing refractory compounds are being developed for the rare isotope accelerator (RIA) facility to produce ion species far from stability. With the 100 kW beams proposed for the production targets, dissipation of heat becomes a challenging issue. In our two-step target design, neutrons are generated in a refractory primary target, inducing fission in the surrounding uranium carbide. The interplay of density, grain size, thermal conductivity and diffusion properties of the UC2 needs to be well understood before fabrication. Thin samples of uranium carbide were prepared for thermal conductivity measurements using an electron beam to heat the sample and an optical pyrometer to observe the thermal radiation. Release efficiencies and independent thermal analysis on these samples are being undertaken at Oak Ridge National Laboratory (ORNL). An alternate target concept for RIA, the tilted slab approach promises to be simple with fast ion release and capable of withstanding high beam intensities while providing considerable yields via spallation. A proposed small business innovative research (SBIR) project will design a prototype tilted target, exploring the materials needed for fabrication and testing at an irradiation facility to address issues of heat transfer and stresses within the target.

  9. [Overgeneral autobiographical memory in depressive disorders].

    PubMed

    Dutra, Tarcísio Gomes; Kurtinaitis, Laila da Camara Lima; Cantilino, Amaury; Vasconcelos, Maria Carolina Souto de; Hazin, Izabel; Sougey, Everton Botelho

    2012-01-01

    This article aims to review studies focusing on the relationship between overgeneral autobiographical memory and depressive disorders. Such characteristic has attracted attention because of its relationship with a poor ability to solve problems and to imagine the future, as well as with the maintenance and a poor prognosis of depression. Data were collected through a systematic search on LILACS, SciELO, MEDLINE, and IBECS databases, and also on the health sciences records of Portal de Periódicos da Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES), a Brazilian journal database, focusing on articles published between 2000 and 2010. The following keywords were used: memória autobiográfica, supergeneralização da memória autobiográfica, and memória autobiográfica e depressão in Portuguese; and autobiographical memory, overgeneral autobiographical memory, and autobiographical memory and depression in English. Following application of exclusion criteria, a total of 27 studies were reviewed. Overgeneral autobiographical memory has been investigated in several depressive disorders. However, further longitudinal studies are required to confirm the relevant role of this cognitive characteristic in anamnesis and in the treatment of mood disorders.

  10. Sex-specific association between infant diet and white matter integrity in 8-y-old children.

    PubMed

    Ou, Xiawei; Andres, Aline; Cleves, Mario A; Pivik, R T; Snow, Jeffrey H; Ding, Zhaohua; Badger, Thomas M

    2014-12-01

    The American Academy of Pediatrics recommends breastfeeding, which is well known to promote cognitive and behavioral development. The evidence for why this occurs is not well understood. Fifty-six 7.5- to 8.5-y-old healthy children were breastfed (BF; n = 22, 10 males) or formula-fed (FF; n = 34, 16 males) as infants. All children were administered: the Reynolds Intellectual Assessment Scale (RIAS); the Clinical Evaluation of Language Fundamentals (CELF-4) tests; and magnetic resonance imaging of the brain. Diffusion tensor imaging (DTI) measured fractional anisotropy (FA) values were correlated with RIAS and CELF-4 scores. DTI tract-based spatial statistics (TBSS) analyses showed multiple white matter regions in the left hemisphere with significantly higher FA (P < 0.05, corrected) values in BF than FF males, but no significant group differences in females. Males who were exclusively BF for at least 1 y appeared to have the greatest differences in FA. Mean FA values positively correlated with composite scores of RIAS (P = 0.03) and CELF-4 (P = 0.02). Breastfeeding during infancy was associated with better white matter development at 8 y of age in boys. A similar association was not observed in girls.

  11. The use of experimental data in an MTR-type nuclear reactor safety analysis

    NASA Astrophysics Data System (ADS)

    Day, Simon E.

    Reactivity initiated accidents (RIAs) are a category of events required for research reactor safety analysis. A subset of this is unprotected RIAs in which mechanical systems or human intervention are not credited in the response of the system. Light-water cooled and moderated MTR-type ( i.e., aluminum-clad uranium plate fuel) reactors are self-limiting up to some reactivity insertion limit beyond which fuel damage occurs. This characteristic was studied in the Borax and Spert reactor tests of the 1950s and 1960s in the USA. This thesis considers the use of this experimental data in generic MTR-type reactor safety analysis. The approach presented herein is based on fundamental phenomenological understanding and uses correlations in the reactor test data with suitable account taken for differences in important system parameters. Specifically, a semi-empirical approach is used to quantify the relationship between the power, energy and temperature rise response of the system as well as parametric dependencies on void coefficient and the degree of subcooling. Secondary effects including the dependence on coolant flow are also examined. A rigorous curve fitting approach and error assessment is used to quantify the trends in the experimental data. In addition to the initial power burst stage of an unprotected transient, the longer term stability of the system is considered with a stylized treatment of characteristic power/temperature oscillations (chugging). A bridge from the HEU-based experimental data to the LEU fuel cycle is assessed and outlined based on existing simulation results presented in the literature. A cell-model based parametric study is included. The results are used to construct a practical safety analysis methodology for determining reactivity insertion safety limits for a light-water moderated and cooled MTR-type core.

  12. Clinical characteristics of patients with thyrotropin-secreting pituitary adenoma.

    PubMed

    Wu, Yung-Yen; Chang, Hung-Yu; Lin, Jen-Der; Chen, Kwang-Wen; Huang, Yu-Yao; Jung, Shih-Ming

    2003-03-01

    Thyroid-stimulating hormone (thyrotropin, TSH)-secreting pituitary adenoma is a very rare cause of hyperthyroidism. Diagnosis of this condition is often delayed due to lack of availability of TSH radioimmunoassay (RIA), the failure to recognize the utility of RIA and the incorrect attribution of the condition to other causes of thyrotoxicosis. This retrospective study analyzed the clinical characteristics of patients with this disorder treated from 1991 to 2002. Seven patients (6 females, 1 male; mean age, 48 years; range, 33 to 72 years) with a diagnosis of TSHsecreting pituitary adenoma based on detectable TSH levels with high serum free thyroid hormone or triiodothyronine concentrations and pituitary lesions found on neuroimaging were included in this study. Patient records including clinical features, endocrine studies, immunohistochemistry studies, and response to treatment were reviewed. All 7 patients had hyperthyroidism, elevated free thyroxine or triiodothyronine levels, and unsuppressed levels of TSH. Imaging studies demonstrated a pituitary mass or lesion in all patients. Six patients had macroadenomas and 1 patient had a microadenoma. One of the patients had coexisting acromegalic features and hypersecretion of growth hormone was diagnosed. All of the patients had been treated with thionamides or thyroidectomy for presumed primary hyperthyroidism. Serum alpha-subunit level was uncharacteristically normal in 2 patients and elevated in 1 patient. Alpha-subunit/TSH molar ratios were elevated in 3 patients. Five patients underwent transsphenoidal adenomectomy but only one of them remained well-controlled at follow-up. Three patients received administration of somatostatin analogs and they achieved normalization of serum TSH and free thyroid hormones during the period of therapy. TSH immunoassay has an important role in the evaluation of hyperthyroid patients to determine the presence of inappropriate secretion. TSH-secreting pituitary adenoma exhibits heterogeneity in clinical presentation, hormonal expression and therapeutic response.

  13. Physics division annual report 2000.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thayer, K., ed.

    2001-10-04

    This report summarizes the research performed in 2000 in the Physics Division of Argonne National Laboratory. The Division's programs include operation of ATLAS as a national user facility, nuclear structure and reaction research, nuclear theory and medium energy physics research, and accelerator research and development. As the Nuclear Science Advisory Committee and the nuclear science community create a new long range plan for the field in 2001, it is clear that the research of the Division is closely aligned with and continues to help define the national goals of our field. The NSAC 2001 Long Range Plan recommends as themore » highest priority for major new construction the Rare Isotope Accelerator (RIA), a bold step forward for nuclear structure and nuclear astrophysics. The accelerator R&D in the Physics Division has made major contributions to almost all aspects of the RIA design concept and the community was convinced that this project is ready to move forward. 2000 saw the end of the first Gammasphere epoch at ATLAS, One hundred Gammasphere experiments were completed between January 1998 and March 2000, 60% of which used the Fragment Mass Analyzer to provide mass identification in the reaction. The experimental program at ATLAS then shifted to other important research avenues including proton radioactivity, mass measurements with the Canadian Penning Trap and measurements of high energy gamma-rays in nuclear reactions with the MSU/ORNL/Texas A&M BaF{sub 2} array. ATLAS provided 5460 beam-research hours for user experiments and maintained an operational reliability of 95%. Radioactive beams accounted for 7% of the beam time. ATLAS also provided a crucial test of a key RIA concept, the ability to accelerate multiple charge states in a superconducting heavy-ion linac. This new capability was immediately used to increase the performance for a scheduled experiment. The medium energy program continued to make strides in examining how the quark-gluon structure of matter impacts the structure of nuclei and extended the exquisite sensitivity of the Atom-Trap-Trace-Analysis technique to new species and applications. All of this progress was built on advances in nuclear theory, which the Division pursues at the quark, hadron, and nuclear collective degrees of freedom levels. These are just a few of the highlights in the Division's research program. The results reflect the talents and dedication of the Physics Division staff and the visitors, guests and students who bring so much to the research.« less

  14. U-Pb SHRIMP-RG zircon ages and Nd signature of lower Paleozoic rifting-related magmatism in the Variscan basement of the Eastern Pyrenees

    USGS Publications Warehouse

    Martinez, F.J.; Iriondo, A.; Dietsch, C.; Aleinikoff, J.N.; Peucat, J.J.; Cires, J.; Reche, J.; Capdevila, R.

    2011-01-01

    The ages of orthogneisses exposed in massifs of the Variscan chain can determine whether they are part of a pre-Neoproterozoic basement, a Neoproterozoic, Panafrican arc, or are, in fact, lower Paleozoic, and their isotopic compositions can be used to probe the nature of their source rocks, adding to the understanding of the types, distribution, and tectonic evolution of peri-Gondwanan crystalline basement. Using SHRIMP U-Pb zircon geochronology and Nd isotopic analysis, pre-Variscan metaigneous rocks from the N??ria massif in the Eastern Pyrenean axial zone and the Guilleries massif, 70km to the south, have been dated and their Nd signatures characterized. All dated orthogneisses from the N??ria massif have the same age within error, ~457Ma, including the Ribes granophyre, interpreted as a subvolcanic unit within Caradocian sediments contemporaneous with granitic magmas intruded into Cambro-Ordovician sediments at deeper levels. Orthogneisses in the Guilleries massif record essentially continuous magmatic activity during the Ordovician, beginning at the Cambro-Ordovician boundary (488??3Ma) and reaching a peak in the volume of magma in the early Late Ordovician (~460Ma). Metavolcanic rocks in the Guilleries massif were extruded at 452??4Ma and appear to have their intrusive equivalent in thin, deformed veins of granitic gneiss (451??7Ma) within metasedimentary rocks. In orthogneisses from both massifs, the cores of some zircons yield Neoproterozoic ages between ~520 and 900Ma. The age of deposition of a pre-Late Ordovician metapelite in the Guilleries massif is bracketed by the weighted average age of the youngest detrital zircon population, 582??11Ma, and the age of cross-cutting granitic veins, 451??7Ma. Older detrital zircons populations in this metapelite include Neoproterozoic (749-610Ma; n=10), Neo- to Mesoproterozoic (1.04-0.86Ga; n=7), Paleoproterozoic (2.02-1.59Ga; n=5), and Neoarchean (2.74-2.58Ga; n=3). Nd isotopic analyses of the N??ria and Guilleries orthogneisses yielded negative ??Nd values ranging between -2.1 and -5.2 at 450Ma, the same as Ediacaran sediments from northwestern Iberia. We interpret these slightly negative ??Nd values as a signature of Panafrican arc rocks, mixed with an older crustal component as indicated by the inherited and detrital zircon ages we analyzed. The crustal level in which Ordovician melting occurred has not been recognized and the absence of pre-Neoproterozoic basement is a striking feature of the southern part of the Variscan Chain. ?? 2011 Elsevier B.V.

  15. Impact Damage and Strain Rate Effects for Toughened Epoxy Composite Structures

    NASA Technical Reports Server (NTRS)

    Chamis, Christos C.; Minnetyan, Levon

    2006-01-01

    Structural integrity of composite systems under dynamic impact loading is investigated herein. The GENOA virtual testing software environment is used to implement the effects of dynamic loading on fracture progression and damage tolerance. Combinations of graphite and glass fibers with a toughened epoxy matrix are investigated. The effect of a ceramic coating for the absorption of impact energy is also included. Impact and post impact simulations include verification and prediction of (1) Load and Impact Energy, (2) Impact Damage Size, (3) Maximum Impact Peak Load, (4) Residual Strength, (5) Maximum Displacement, (6) Contribution of Failure Modes to Failure Mechanisms, (7) Prediction of Impact Load Versus Time, and (8) Damage, and Fracture Pattern. A computer model is utilized for the assessment of structural response, progressive fracture, and defect/damage tolerance characteristics. Results show the damage progression sequence and the changes in the structural response characteristics due to dynamic impact. The fundamental premise of computational simulation is that the complete evaluation of composite fracture requires an assessment of ply and subply level damage/fracture processes as the structure is subjected to loads. Simulation results for the graphite/epoxy composite were compared with the impact and tension failure test data, correlation and verification was obtained that included: (1) impact energy, (2) damage size, (3) maximum impact peak load, (4) residual strength, (5) maximum displacement, and (6) failure mechanisms of the composite structure.

  16. Allostatic load and socioeconomic status in Polish adult men.

    PubMed

    Lipowicz, Anna; Szklarska, Alicja; Malina, Robert M

    2014-03-01

    This study considers the relationship between a cumulative index of biological dysregulation (allostatic load) and several dimensions of socioeconomic status (SES) and lifestyle in adult Polish males. The extent to which lifestyle variables can explain SES variation in allostatic load was also evaluated. Participants were 3887 occupationally active men aged 25-60 years living in cities and villages in the Silesia region of Poland. The allostatic load indicator included eleven markers: % fat (adverse nutritional intake), systolic and diastolic blood pressures (cardiovascular activity), FEV1 (lung function), erythrocyte sedimentation rate (inflammatory processes), glucose and total cholesterol (cardiovascular disease risk), total plasma protein (stress-haemoconcentration), bilirubin, creatinine clearance and alkaline phosphatase activity (hepatic and renal functions). A higher level of completed education, being married and residing in an urban area were associated with lower physiological dysregulation. The association between indicators of SES and allostatic load was not eliminated or attenuated when unhealthy lifestyle variables were included in the model. Smoking status and alcohol consumption played minimal roles in explaining the association between SES and allostatic load; physical activity, however, had a generally protective effect on allostatic load.

  17. A radioimmunoassay for ependymins beta and gamma: two goldfish brain proteins involved in behavioral plasticity.

    PubMed

    Schmidt, R; Shashoua, V E

    1981-04-01

    A radioimmunoassay (RIA) using 125I-labeled antigen was developed for the quantitative determination of two goldfish brain proteins (ependymins beta and gamma). The proteins were isolated from the cerebrospinal fluid (CSF) and cells of the ependymal zone surrounding goldfish brain ventricles. The turnover rates of beta and gamma were previously shown to be specifically enhanced after the animals successfully acquired a new pattern of swimming behavior. Femtomole quantities of ependymin beta were measurable by the RIA. In applications of the assay, beta and gamma ependymins were found to have common immunological properties, since 125I-beta-antigen bound to antibody could be displaced by unlabeled ependymin gamma as well as ependymin beta but not by a variety of other proteins including several purified glycoproteins isolated from goldfish brain. The ependymins were shown to constitute 14% of the total protein content of the brain extracellular fluid and also to be present as a minor component of the serum proteins (0.3%). Ependymins beta and gamma have an immunological reactivity in these fractions that can be increased by a factor of 30 on heating. The data suggest that the antigenicity of the molecules is highly masked, and that it may require some unraveling of the quaternary structure of the proteins before maximal interaction with the antisera becomes possible.

  18. Spatial distribution patterns and movements of Holothuria arguinensis in the Ria Formosa (Portugal)

    NASA Astrophysics Data System (ADS)

    Siegenthaler, Andjin; Cánovas, Fernando; González-Wangüemert, Mercedes

    2015-08-01

    Holothurian populations are under pressure worldwide because of increasing demand for beche-de-mer, mainly for Asian consumption. Importations to this area from new temperate fishing grounds provide economic opportunities but also raise concerns regarding future over-exploitation. Studies on the habitat preferences and movements of sea cucumbers are important for the management of sea cucumber stocks and sizing of no-take zones, but information on the ecology and behavior of temperate sea cucumbers is scarce. This study describes the small-scale distribution and movement patterns of Holothuria arguinensis in the intertidal zone of the Ria Formosa national park (Portugal). Mark/recapture studies were performed to record their movements over time on different habitats (sand and seagrass). H. arguinensis preferred seagrass habitats and did not show a size or life stage-related spatial segregation. Its density was 563 ind. ha- 1 and mean movement speed was 10 m per day. Movement speed did not differ between habitats and the direction of movement was offshore during the day and shoreward during the night. Median home range size was 35 m2 and overlap among home ranges was 84%. H. arguinensis' high abundance, close association with seagrass and easy catchability in the intertidal zone, indicate the importance of including intertidal lagoons in future studies on temperate sea cucumber ecology since those systems might require different management strategies than fully submerged habitats.

  19. Seasonal Patterns of Melatonin, Cortisol, and Progesterone Secretion in Female Lambs Raised Beneath a 500-KV Transmission Line

    NASA Astrophysics Data System (ADS)

    Lee, Jack Monroe, Jr.

    There is ongoing controversy about the possibility of adverse biological effects from environmental exposures to electric and magnetic fields. These fields are produced by all electrical equipment and appliances including electrical transmission lines. The objective of this environmental science study was to investigate the possible effects of a high voltage transmission line on domestic sheep (Ovis aries L.), a species that can often be found near such lines. The study was primarily designed to determine whether a specific effect of electric and magnetic fields found in laboratory animals also occurs in livestock under natural environmental conditions. The effect is the ability of fields, at levels found in the environment, to significantly depress the normally high nocturnal concentrations of the pineal hormone-melatonin. Ten female Suffolk lambs were penned for 10 months directly beneath a 500-kV transmission line near Estacada, Oregon. Ten other lambs of the same type were penned in a control area away from the transmission line where electric and magnetic fields were at ambient levels. Serum melatonin was analyzed by radioimmunoassay (RIA) from 6618 blood samples collected at 0.5 to 3-hour intervals over eight 48-hour periods. Serum progesterone was analyzed by RIA from blood samples collected twice weekly. Serum cortisol was also assayed by RIA from the blood samples collected during the 48-hour samples. Results showed that lambs in both the control and line groups had the typical pattern of melatonin secretion consisting of low daytime and high nighttime serum concentrations. There were no statistically significant differences between groups in melatonin levels, or in the phase or duration of the nighttime melatonin elevation. Age at puberty and number of reproductive cycles also did not differ between groups. Serum cortisol showed a circadian rhythm with highest concentrations during the day. There were, however, no differences in cortisol concentrations between groups. Statistical analyses on other biological parameters revealed no differences between groups for body weight gain, wool growth, or behavior.

  20. Genome mining and functional genomics for siderophore production in Aspergillus niger.

    PubMed

    Franken, Angelique C W; Lechner, Beatrix E; Werner, Ernst R; Haas, Hubertus; Lokman, B Christien; Ram, Arthur F J; van den Hondel, Cees A M J J; de Weert, Sandra; Punt, Peter J

    2014-11-01

    Iron is an essential metal for many organisms, but the biologically relevant form of iron is scarce because of rapid oxidation resulting in low solubility. Simultaneously, excessive accumulation of iron is toxic. Consequently, iron uptake is a highly controlled process. In most fungal species, siderophores play a central role in iron handling. Siderophores are small iron-specific chelators that can be secreted to scavenge environmental iron or bind intracellular iron with high affinity. A second high-affinity iron uptake mechanism is reductive iron assimilation (RIA). As shown in Aspergillus fumigatus and Aspergillus nidulans, synthesis of siderophores in Aspergilli is predominantly under control of the transcription factors SreA and HapX, which are connected by a negative transcriptional feedback loop. Abolishing this fine-tuned regulation corroborates iron homeostasis, including heme biosynthesis, which could be biotechnologically of interest, e.g. the heterologous production of heme-dependent peroxidases. Aspergillus niger genome inspection identified orthologues of several genes relevant for RIA and siderophore metabolism, as well as sreA and hapX. Interestingly, genes related to synthesis of the common fungal extracellular siderophore triacetylfusarinine C were absent. Reverse-phase high-performance liquid chromatography (HPLC) confirmed the absence of triacetylfusarinine C, and demonstrated that the major secreted siderophores of A. niger are coprogen B and ferrichrome, which is also the dominant intracellular siderophore. In A. niger wild type grown under iron-replete conditions, the expression of genes involved in coprogen biosynthesis and RIA was low in the exponential growth phase but significantly induced during ascospore germination. Deletion of sreA in A. niger resulted in elevated iron uptake and increased cellular ferrichrome accumulation. Increased sensitivity toward phleomycin and high iron concentration reflected the toxic effects of excessive iron uptake. Moreover, SreA-deficiency resulted in increased accumulation of heme intermediates, but no significant increase in heme content. Together with the upregulation of several heme biosynthesis genes, these results reveal a complex heme regulatory mechanism. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  1. Learner, Patient, and Supervisor Features Are Associated With Different Types of Cognitive Load During Procedural Skills Training: Implications for Teaching and Instructional Design.

    PubMed

    Sewell, Justin L; Boscardin, Christy K; Young, John Q; Ten Cate, Olle; O'Sullivan, Patricia S

    2017-11-01

    Cognitive load theory, focusing on limits of the working memory, is relevant to medical education; however, factors associated with cognitive load during procedural skills training are not well characterized. The authors sought to determine how features of learners, patients/tasks, settings, and supervisors were associated with three types of cognitive load among learners performing a specific procedure, colonoscopy, to identify implications for procedural teaching. Data were collected through an electronically administered survey sent to 1,061 U.S. gastroenterology fellows during the 2014-2015 academic year; 477 (45.0%) participated. Participants completed the survey immediately following a colonoscopy. Using multivariable linear regression analyses, the authors identified sets of features associated with intrinsic, extraneous, and germane loads. Features associated with intrinsic load included learners (prior experience and year in training negatively associated, fatigue positively associated) and patient/tasks (procedural complexity positively associated, better patient tolerance negatively associated). Features associated with extraneous load included learners (fatigue positively associated), setting (queue order positively associated), and supervisors (supervisor engagement and confidence negatively associated). Only one feature, supervisor engagement, was (positively) associated with germane load. These data support practical recommendations for teaching procedural skills through the lens of cognitive load theory. To optimize intrinsic load, level of experience and competence of learners should be balanced with procedural complexity; part-task approaches and scaffolding may be beneficial. To reduce extraneous load, teachers should remain engaged, and factors within the procedural setting that may interfere with learning should be minimized. To optimize germane load, teachers should remain engaged.

  2. Composite load spectra for select space propulsion structural components

    NASA Technical Reports Server (NTRS)

    Newell, J. F.; Ho, H. W.; Kurth, R. E.

    1991-01-01

    The work performed to develop composite load spectra (CLS) for the Space Shuttle Main Engine (SSME) using probabilistic methods. The three methods were implemented to be the engine system influence model. RASCAL was chosen to be the principal method as most component load models were implemented with the method. Validation of RASCAL was performed. High accuracy comparable to the Monte Carlo method can be obtained if a large enough bin size is used. Generic probabilistic models were developed and implemented for load calculations using the probabilistic methods discussed above. Each engine mission, either a real fighter or a test, has three mission phases: the engine start transient phase, the steady state phase, and the engine cut off transient phase. Power level and engine operating inlet conditions change during a mission. The load calculation module provides the steady-state and quasi-steady state calculation procedures with duty-cycle-data option. The quasi-steady state procedure is for engine transient phase calculations. In addition, a few generic probabilistic load models were also developed for specific conditions. These include the fixed transient spike model, the poison arrival transient spike model, and the rare event model. These generic probabilistic load models provide sufficient latitude for simulating loads with specific conditions. For SSME components, turbine blades, transfer ducts, LOX post, and the high pressure oxidizer turbopump (HPOTP) discharge duct were selected for application of the CLS program. They include static pressure loads and dynamic pressure loads for all four components, centrifugal force for the turbine blade, temperatures of thermal loads for all four components, and structural vibration loads for the ducts and LOX posts.

  3. 29 CFR 1910.181 - Derricks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., working means the external load, in pounds, applied to the derrick, including the weight of load attaching... securely affixed where it is visible to personnel responsible for the safe operation of the equipment. The... of service, and environment, or as specifically indicated below. These inspections shall include the...

  4. Measuring alignment of loading fixture

    DOEpatents

    Scavone, Donald W.

    1989-01-01

    An apparatus and method for measuring the alignment of a clevis and pin type loading fixture for compact tension specimens include a pair of substantially identical flat loading ligaments. Each loading ligament has two apertures for the reception of a respective pin of the loading fixture and a thickness less than one-half of a width of the clevis opening. The pair of loading ligaments are mounted in the clevis openings at respective sides thereof. The loading ligaments are then loaded by the pins of the loading fixture and the strain in each loading ligament is measured. By comparing the relative strain of each loading ligament, the alignment of the loading fixture is determined. Preferably, a suitable strain gage device is located at each longitudinal edge of a respective loading ligament equidistant from the two apertures in order to determine the strain thereat and hence the strain of each ligament. The loading ligaments are made substantially identical by jig grinding the loading ligaments as a matched set. Each loading ligament can also be individually calibrated prior to the measurement.

  5. Characterizing the uncertainty in holddown post load measurements

    NASA Technical Reports Server (NTRS)

    Richardson, J. A.; Townsend, J. S.

    1993-01-01

    In order to understand unexpectedly erratic load measurements in the launch-pad supports for the space shuttle, the sensitivities of the load cells in the supports were analyzed using simple probabilistic techniques. NASA engineers use the loads in the shuttle's supports to calculate critical stresses in the shuttle vehicle just before lift-off. The support loads are measured with 'load cells' which are actually structural components of the mobile launch platform which have been instrumented with strain gauges. Although these load cells adequately measure vertical loads, the horizontal load measurements have been erratic. The load measurements were simulated in this study using Monte Carlo simulation procedures. The simulation studies showed that the support loads are sensitive to small deviations in strain and calibration. In their current configuration, the load cells will not measure loads with sufficient accuracy to reliably calculate stresses in the shuttle vehicle. A simplified model of the holddown post (HDP) load measurement system was used to study the effect on load measurement accuracy for several factors, including load point deviations, gauge heights, and HDP geometry.

  6. Passive detection of vehicle loading

    NASA Astrophysics Data System (ADS)

    McKay, Troy R.; Salvaggio, Carl; Faulring, Jason W.; Salvaggio, Philip S.; McKeown, Donald M.; Garrett, Alfred J.; Coleman, David H.; Koffman, Larry D.

    2012-01-01

    The Digital Imaging and Remote Sensing Laboratory (DIRS) at the Rochester Institute of Technology, along with the Savannah River National Laboratory is investigating passive methods to quantify vehicle loading. The research described in this paper investigates multiple vehicle indicators including brake temperature, tire temperature, engine temperature, acceleration and deceleration rates, engine acoustics, suspension response, tire deformation and vibrational response. Our investigation into these variables includes building and implementing a sensing system for data collection as well as multiple full-scale vehicle tests. The sensing system includes; infrared video cameras, triaxial accelerometers, microphones, video cameras and thermocouples. The full scale testing includes both a medium size dump truck and a tractor-trailer truck on closed courses with loads spanning the full range of the vehicle's capacity. Statistical analysis of the collected data is used to determine the effectiveness of each of the indicators for characterizing the weight of a vehicle. The final sensing system will monitor multiple load indicators and combine the results to achieve a more accurate measurement than any of the indicators could provide alone.

  7. Load research manual. Volume 2. Fundamentals of implementing load research procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. In Volumes 1 and 2, procedures are suggested for determining data requirements for load research, establishing the size and customer composition of a load survey sample, selecting and using equipment to record customer electricity usage, processing data tapes from the recording equipment, and analyzing the data. Statistical techniques used in customer sampling are discussedmore » in detail. The costs of load research also are estimated, and ongoing load research programs at three utilities are described. The manual includes guides to load research literature and glossaries of load research and statistical terms.« less

  8. Load evaluation of the da Vinci surgical system for transoral robotic surgery.

    PubMed

    Fujiwara, Kazunori; Fukuhara, Takahiro; Niimi, Koji; Sato, Takahiro; Kitano, Hiroya

    2015-12-01

    Transoral robotic surgery, performed with the da Vinci surgical system (da Vinci), is a surgical approach for benign and malignant lesions of the oral cavity and laryngopharynx. It provides several unique advantages, which include a 3-dimensional magnified view and ability to see and work around curves or angles. However, the current da Vinci surgical system does not provide haptic feedback. This is problematic because the potential risks specific to the transoral use of the da Vinci include tooth injury, mucosal laceration, ocular injury and mandibular fracture. To assess the potential for intraoperative injuries, we measured the load of the endoscope and the instrument of the da Vinci Si surgical system. We pressed the endoscope and instrument of the da Vinci Si against Load cell six times each and measured the dynamic load and the time-to-maximum load. We also struck the da Vinci Si endoscope and instrument against the Load cell six times each and measured the impact load. The maximum dynamic load was 7.27 ± 1.31 kg for the endoscope and 1.90 ± 0.72 for the instrument. The corresponding time-to-maximum loads were 1.72 ± 0.22 and 1.29 ± 0.34 s, but the impact loads were significantly lower than the dynamic load. It remains possible that a major load is exerted on adjacent structures by continuous contact with the endoscope and instrument of da Vinci Si. However, there is a minor delay in reaching the maximum load. Careful monitoring by an on-site assistant may, therefore, help prevent contiguous injury.

  9. Use of Flexible Body Coupled Loads in Assessment of Day of Launch Flight Loads

    NASA Technical Reports Server (NTRS)

    Starr, Brett R.; Yunis, Isam; Olds, Aaron D.

    2011-01-01

    A Day of Launch flight loads assessment technique that determines running loads calculated from flexible body coupled loads was developed for the Ares I-X Flight Test Vehicle. The technique was developed to quantify DOL flight loads in terms of structural load components rather than the typically used q-alpha metric to provide more insight into the DOL loads. In this technique, running loads in the primary structure are determined from the combination of quasi-static aerodynamic loads and dynamic loads. The aerodynamic loads are calculated as a function of time using trajectory parameters passed from the DOL trajectory simulation and are combined with precalculated dynamic loads using a load combination equation. The potential change in aerodynamic load due to wind variability during the countdown is included in the load combination. In the event of a load limit exceedance, the technique allows the identification of what load component is exceeded, a quantification of how much the load limit is exceeded, and where on the vehicle the exceedance occurs. This technique was used to clear the Ares I-X FTV for launch on October 28, 2009. This paper describes the use of coupled loads in the Ares I-X flight loads assessment and summarizes the Ares I-X load assessment results.

  10. Load sensing system

    DOEpatents

    Sohns, C.W.; Nodine, R.N.; Wallace, S.A.

    1999-05-04

    A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast inventories of stored nuclear material can be continuously monitored and inventoried of minimal cost. 4 figs.

  11. Multifunctional High Drug Loading Nanocarriers for Cancer Drug Delivery

    NASA Astrophysics Data System (ADS)

    Jin, Erlei

    2011-12-01

    Most anticancer drugs have poor water-solubility, rapid blood clearance, low tumor-selectivity and severe systemic toxicity to healthy tissues. Thus, polymeric nanocarriers have been widely explored for anticancer drugs to solve these problems. However, polymer nanocarriers developed to date still suffer drawbacks including low drug loading contents, premature drug release, slow cellular internalization, slow intracellular drug release and thereby low therapeutic efficiency in cancer thermotherapy. Accordingly, in this dissertation, functional nanocapsules and nanoparticles including high drug loading liposome-like nanocapsules, high drug loading phospholipid-mimic nanocapsules with fast intracellular drug release, high drug loading charge-reversal nanocapsules, TAT based long blood circulation nanoparticles and charge-reversal nuclear targeted nanoparticles are designed and synthesized. These functional carriers have advantages such as high drug loading contents without premature drug release, fast cellular internalization and intracellular drug release, nuclear targeted delivery and long blood circulation. As a result, all these drug carriers show much higher in vitro and in vivo anti-cancer activities.

  12. Experimental Investigation and Fundamental Understanding of a Slowed UH-60A Rotor at High Advance Ratios

    NASA Technical Reports Server (NTRS)

    Datta, Anubhav; Yeo, Hyeonsoo; Norman, Thomas R.

    2011-01-01

    This paper describes and analyzes the measurements from a full-scale, slowed RPM, UH-60A rotor tested at the National Full-Scale Aerodynamics Complex 40- by 80- ft wind tunnel up to an advance ratio of 1.0. A comprehensive set of measurements, that includes performance, blade loads, hub loads and pressures/airloads makes this data set unique. The measurements reveal new and rich aeromechanical phenomena that are special to this exotic regime. These include reverse chord dynamic stall, retreating side impulse in pitch-link load, large inboard-outboard elastic twist differential, supersonic flow at low subsonic advancing tip Mach numbers, diminishing rotor forces yet dramatic build up of blade loads, and dramatic blade loads yet benign levels of vibratory hub loads. The objective of this research is the fundamental understanding of these unique aeromechanical phenomena. The intent is to provide useful knowledge for the design of high speed, high efficiency, slowed RPM rotors of the future and a challenging database for advanced analyses validation.

  13. AC resistance measuring instrument

    DOEpatents

    Hof, P.J.

    1983-10-04

    An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument. 8 figs.

  14. AC Resistance measuring instrument

    DOEpatents

    Hof, Peter J.

    1983-01-01

    An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument.

  15. Stereo photo series for quantifying natural fuels Volume X: sagebrush with grass and ponderosa pine-juniper types in central Montana.

    Treesearch

    Roger D. Ottmar; Robert E. Vihnanek; Clinton S. Wright

    2007-01-01

    Two series of single and stereo photographs display a range of natural conditions and fuel loadings in sagebrush with grass and ponderosa pinejuniper types in central Montana. Each group of photos includes inventory information summarizing vegetation composition, structure, and loading; woody material loading and density by size class; forest floor depth and loading;...

  16. Estimating Escherichia coli loads in streams based on various physical, chemical, and biological factors

    PubMed Central

    Dwivedi, Dipankar; Mohanty, Binayak P.; Lesikar, Bruce J.

    2013-01-01

    Microbes have been identified as a major contaminant of water resources. Escherichia coli (E. coli) is a commonly used indicator organism. It is well recognized that the fate of E. coli in surface water systems is governed by multiple physical, chemical, and biological factors. The aim of this work is to provide insight into the physical, chemical, and biological factors along with their interactions that are critical in the estimation of E. coli loads in surface streams. There are various models to predict E. coli loads in streams, but they tend to be system or site specific or overly complex without enhancing our understanding of these factors. Hence, based on available data, a Bayesian Neural Network (BNN) is presented for estimating E. coli loads based on physical, chemical, and biological factors in streams. The BNN has the dual advantage of overcoming the absence of quality data (with regards to consistency in data) and determination of mechanistic model parameters by employing a probabilistic framework. This study evaluates whether the BNN model can be an effective alternative tool to mechanistic models for E. coli loads estimation in streams. For this purpose, a comparison with a traditional model (LOADEST, USGS) is conducted. The models are compared for estimated E. coli loads based on available water quality data in Plum Creek, Texas. All the model efficiency measures suggest that overall E. coli loads estimations by the BNN model are better than the E. coli loads estimations by the LOADEST model on all the three occasions (three-fold cross validation). Thirteen factors were used for estimating E. coli loads with the exhaustive feature selection technique, which indicated that six of thirteen factors are important for estimating E. coli loads. Physical factors included temperature and dissolved oxygen; chemical factors include phosphate and ammonia; biological factors include suspended solids and chlorophyll. The results highlight that the LOADEST model estimates E. coli loads better in the smaller ranges, whereas the BNN model estimates E. coli loads better in the higher ranges. Hence, the BNN model can be used to design targeted monitoring programs and implement regulatory standards through TMDL programs. PMID:24511166

  17. Linear transformer driver for pulse generation with fifth harmonic

    DOEpatents

    Mazarakis, Michael G.; Kim, Alexander A.; Sinebryukhov, Vadim A.; Volkov, Sergey N.; Kondratiev, Sergey S.; Alexeenko, Vitaly M.; Bayol, Frederic; Demol, Gauthier; Stygar, William A.; Leckbee, Joshua; Oliver, Bryan V.; Kiefer, Mark L.

    2017-03-21

    A linear transformer driver includes at least one ferrite ring positioned to accept a load. The linear transformer driver also includes a first, second, and third power delivery module. The first power delivery module sends a first energy in the form of a first pulse to the load. The second power delivery module sends a second energy in the form of a second pulse to the load. The third power delivery module sends a third energy in the form of a third pulse to the load. The linear transformer driver is configured to form a flat-top pulse by the superposition of the first, second, and third pulses. The first, second, and third pulses have different frequencies.

  18. Modeling of rolling element bearing mechanics

    NASA Technical Reports Server (NTRS)

    Greenhill, L. M.

    1991-01-01

    Roller element bearings provide the primary mechanical interface between rotating and nonrotating components in the high performance turbomachinery of the Space Shuttle Main Engine (SSME). Knowledge of bearing behavior under various loading and environmental conditions is essential to predicting and understanding the overall behavior of turbopumps, including rotordynamic stability, critical speeds and bearing life. The objective is to develop mathematical models and computer programs to describe the mechanical behavior of ball and cylinder roller bearings under the loading and environmental conditions encountered in the SSME and future high performance rocket engines. This includes characteristics such as nonlinear load/motion relationships, stiffness and damping, rolling element loads for life prediction, and roller and cage stability.

  19. Gas tube-switched high voltage DC power converter

    DOEpatents

    She, Xu; Bray, James William; Sommerer, Timothy John; Chokhawala, Rahul

    2018-05-15

    A direct current (DC)-DC converter includes a transformer and a gas tube-switched inverter circuit. The transformer includes a primary winding and a secondary winding. The gas tube-switched inverter circuit includes first and second inverter load terminals and first and second inverter input terminals. The first and second inverter load terminals are coupled to the primary winding. The first and second inverter input terminals are couplable to a DC node. The gas tube-switched inverter circuit further includes a plurality of gas tube switches respectively coupled between the first and second inverter load terminals and the first and second inverter input terminals. The plurality of gas tube switches is configured to operate to generate an alternating current (AC) voltage at the primary winding.

  20. A free-piston Stirling engine/linear alternator controls and load interaction test facility

    NASA Technical Reports Server (NTRS)

    Rauch, Jeffrey S.; Kankam, M. David; Santiago, Walter; Madi, Frank J.

    1992-01-01

    A test facility at LeRC was assembled for evaluating free-piston Stirling engine/linear alternator control options, and interaction with various electrical loads. This facility is based on a 'SPIKE' engine/alternator. The engine/alternator, a multi-purpose load system, a digital computer based load and facility control, and a data acquisition system with both steady-periodic and transient capability are described. Preliminary steady-periodic results are included for several operating modes of a digital AC parasitic load control. Preliminary results on the transient response to switching a resistive AC user load are discussed.

  1. Concentrations and annual fluxes for selected water-quality constituents from the USGS National Stream Quality Accounting Network (NASQAN) 1996-2000

    USGS Publications Warehouse

    Kelly, Valerie J.; Hooper, Richard P.; Aulenbach, Brent T.; Janet, Mary

    2001-01-01

    This report contains concentrations and annual mass fluxes (loadings) for a broad range of water-quality constituents measured during 1996-2000 as part of the U.S. Geological Survey National Stream Quality Accounting Network (NASQAN). During this period, NASQAN operated a network of 40-42 stations in four of the largest river basins of the USA: the Colorado, the Columbia, the Mississippi (including the Missouri and Ohio), and the Rio Grande. The report contains surface-water quality data, streamflow data, field measurements (e.g. water temperature and pH), sediment-chemistry data, and quality-assurance data; interpretive products include annual and average loads, regression parameters for models used to estimate loads, sub-basin yield maps, maps depicting percent detections for censored constituents, and diagrams depicting flow-weighted average concentrations. Where possible, a regression model relating concentration to discharge and season was used for flux estimation. The interpretive context provided by annual loads includes identifying source and sink areas for constituents and estimating the loadings to receiving waters, such as reservoirs or the ocean.

  2. Wireless power transfer system

    DOEpatents

    Wu, Hunter; Sealy, Kylee; Gilchrist, Aaron

    2016-02-23

    A system includes a first stage of an inductive power transfer system with an LCL load resonant converter with a switching section, an LCL tuning circuit, and a primary receiver pad. The IPT system includes a second stage with a secondary receiver pad, a secondary resonant circuit, a secondary rectification circuit, and a secondary decoupling converter. The secondary receiver pad connects to the secondary resonant circuit. The secondary resonant circuit connects to the secondary rectification circuit. The secondary rectification circuit connects to the secondary decoupling converter. The second stage connects to a load. The load includes an energy storage element. The second stage and load are located on a vehicle and the first stage is located at a fixed location. The primary receiver pad wirelessly transfers power to the secondary receiver pad across a gap when the vehicle positions the secondary receiver pad with respect to the primary receiver pad.

  3. Sonic-boom-induced building structure responses including damage.

    NASA Technical Reports Server (NTRS)

    Clarkson, B. L.; Mayes, W. H.

    1972-01-01

    Concepts of sonic-boom pressure loading of building structures and the associated responses are reviewed, and results of pertinent theoretical and experimental research programs are summarized. The significance of sonic-boom load time histories, including waveshape effects, are illustrated with the aid of simple structural elements such as beams and plates. Also included are discussions of the significance of such other phenomena as three-dimensional loading effects, air cavity coupling, multimodal responses, and structural nonlinearities. Measured deflection, acceleration, and strain data from laboratory models and full-scale building tests are summarized, and these data are compared, where possible, with predicted values. Damage complaint and claim experience due both to controlled and uncontrolled supersonic flights over communities are summarized with particular reference to residential, commercial, and historic buildings. Sonic-boom-induced building responses are compared with those from other impulsive loadings due to natural and cultural events and from laboratory simulation tests.

  4. Parametric Study on the Response of Compression-Loaded Composite Shells With Geometric and Material Imperfections

    NASA Technical Reports Server (NTRS)

    Hilburger, Mark W.; Starnes, James H., Jr.

    2004-01-01

    The results of a parametric study of the effects of initial imperfections on the buckling and postbuckling response of three unstiffened thinwalled compression-loaded graphite-epoxy cylindrical shells with different orthotropic and quasi-isotropic shell-wall laminates are presented. The imperfections considered include initial geometric shell-wall midsurface imperfections, shell-wall thickness variations, local shell-wall ply-gaps associated with the fabrication process, shell-end geometric imperfections, nonuniform applied end loads, and variations in the boundary conditions including the effects of elastic boundary conditions. A high-fidelity nonlinear shell analysis procedure that accurately accounts for the effects of these imperfections on the nonlinear responses and buckling loads of the shells is described. The analysis procedure includes a nonlinear static analysis that predicts stable response characteristics of the shells and a nonlinear transient analysis that predicts unstable response characteristics.

  5. Load apparatus and method for bolt-loaded compact tension test specimen

    DOEpatents

    Buescher, B.J. Jr.; Lloyd, W.R.; Ward, M.B.; Epstein, J.S.

    1997-02-04

    A bolt-loaded compact tension test specimen load apparatus includes: (a) a body having first and second opposing longitudinal ends, the first end comprising an externally threaded portion sized to be threadedly received within the test specimen threaded opening; (b) a longitudinal loading rod having first and second opposing longitudinal ends, the loading rod being slidably received in a longitudinal direction within the body internally through the externally threaded portion and slidably extending longitudinally outward of the body first longitudinal end; (c) a force sensitive transducer slidably received within the body and positioned to engage relative to the loading rod second longitudinal end; and (d) a loading bolt threadedly received relative to the body, the loading bolt having a bearing end surface and being positioned to bear against the transducer to forcibly sandwich the transducer between the loading bolt and loading rod. Also disclosed is a method of in situ determining applied force during crack propagation in a bolt-loaded compact tension test specimen. 6 figs.

  6. Load apparatus and method for bolt-loaded compact tension test specimen

    DOEpatents

    Buescher, Jr., Brent J.; Lloyd, W. Randolph; Ward, Michael B.; Epstein, Jonathan S.

    1997-01-01

    A bolt-loaded compact tension test specimen load apparatus includes: a) a body having first and second opposing longitudinal ends, the first end comprising an externally threaded portion sized to be threadedly received within the test specimen threaded opening; b) a longitudinal loading rod having first and second opposing longitudinal ends, the loading rod being slidably received in a longitudinal direction within the body internally through the externally threaded portion and slidably extending longitudinally outward of the body first longitudinal end; c) a force sensitive transducer slidably received within the body and positioned to engage relative to the loading rod second longitudinal end; and d) a loading bolt threadedly received relative to the body, the loading bolt having a bearing end surface and being positioned to bear against the transducer to forcibly sandwich the transducer between the loading bolt and loading rod. Also disclosed is a method of in situ determining applied force during crack propagation in a bolt-loaded compact tension test specimen.

  7. INFLAMMATORY DISORDERS ASSOCIATED WITH HELICOBACTER PYLORI IN THE ROUX-EN-Y BYPASS GASTRIC POUCH.

    PubMed

    Chaves, Luiz Claudio Lopes; Borges, Isabela Klautau Leite Chaves; Souza, Maíra Danielle Gomes de; Silva, Ian Passos; Silva, Lyz Bezerra; Magalhães, Marcelo Alexandre Prado; Fonseca, Allan Herbert Feliz; Campos, Josemberg Marins

    The prevalence of Helicobacter pylori in obese candidates for bariatric surgery and its role in the emergence of inflammatory lesions after surgery has not been well established. To identify the incidence of inflammatory lesions in the stomach after bariatric surgery and to correlate it with H. pylori infection. This is a prospective study with 216 patients undergoing Roux-en-Y gastric bypass. These patients underwent histopathological endoscopy to detect H. pylori prior to surgery. Positive cases were treated with antibiotics and a proton inhibitor pump followed by endoscopic follow-up in the 6th and 12th month after surgery. Most patients were female (68.1%), with grade III obesity (92.4%). Preoperative endoscopy revealed gastritis in 96.8%, with H. pylori infection in 40.7% (88/216). A biopsy was carried out in 151 patients, revealing H. pylori in 60/151, related to signs of inflammation in 90% (54/60). In the 6th and 12th month after surgery, the endoscopy and the histopathological exam showed a normal gastric pouch in 84% of patients and the incidence of H. pylori was 11% and 16%, respectively. The presence of inflammation was related to H. pylori infection (p<0,001). H. pylori has a similar prevalence in both obese patients scheduled to undergo bariatric surgery and the general population. There is a low incidence of it in the 6th and 12th months after surgery, probably owing to its eradication when detected prior to surgery. When inflammatory disease is present in the new gastric reservoir it is directly related to H. pylori infection. Helicobacter pylori é responsável por várias doenças gastrointestinais. Com o aumento de cirurgia bariátrica no país, há poucos estudos sobre a prevalência desta bactéria em obesos com indicação cirúrgica e o seu papel no surgimento de lesões inflamatórias no pós-operatório. Identificar a incidência de lesões inflamatórias no estômago pós-cirurgia bariátrica e correlacionar com a infecção por H. pylori. Estudo prospectivo com dois grupos de pacientes. Em ambos os grupos verificou-se a prevalência do H. pylori no pré-operatório através de histopatologia, mas em apenas um dos grupos, nos casos de H. pylori positivo realizou-se o tratamento com antibioticoterapia e inibidor de bomba de próton com realização de nova endoscopia no 6° e 12° mês pós-operatório. Avaliou-se 216 pacientes, com as seguintes características: sexo feminino (68,1%), faixa etária entre 30-40 anos, com 31,9% e 31%, respectivamente. De acordo com o IMC, 17,6% apresentavam obesidade moderada, 82,4% obesidade severa/mórbida e 9,7% superobesidade. Nos pacientes submetidos à endoscopia, a positividade do H. pylori se manifestou em 40,7%, sendo responsável pela atividade inflamatória na mucosa gástrica (p<0,001). No pós-operatório, investigou-se a mucosa gástrica através de endoscopia e histopatologia no 6° e 12° mês, que demonstrou normalidade no neorreservatorio gástrico em 84% dos pacientes, e a incidência de H. pylori foi 11% aos seis meses e 16% aos 12 meses, sendo a presença de processo inflamatório relacionado com a infecção pela bactéria (p<0,001). - H. pylori apresenta prevalência similar tanto em obesos que irão submeter-se à cirurgia bariátrica quanto à população em geral; há baixa incidência dele no 6° e 12° mês após a operação e isto deve-se provavelmente à sua erradicação quando detectado no pré-operatório; quando presente a doença inflamatória no neorreservatório gástrico possui relação direta com a infecção por H. pylori.

  8. Basketball lay-up - foot loading characteristics and the number of trials necessary to obtain stable plantar pressure variables.

    PubMed

    Chua, YaoHui K; Quek, Raymond K K; Kong, Pui W

    2017-03-01

    This study aimed (1) to profile the plantar loading characteristics when performing the basketball lay-up in a realistic setting and (2) to determine the number of trials necessary to establish a stable mean for plantar loading variables during the lay-up. Thirteen university male basketball players [age: 23.0 (1.4) years, height: 1.75 (0.05) m, mass: 68.4 (8.6) kg] performed ten successful basketball lay-ups from a stationary position. Plantar loading variables were recorded using the Novel Pedar-X in-shoe system. Loading variables including peak force, peak pressure, and pressure-time integral were extracted from eight foot regions. Performance stability of plantar loading variables during the take-off and landing steps were assessed using the sequential averaging technique and intra-class correlation coefficient (ICC). High plantar loadings were experienced at the heel during the take-off steps, and both the heel and forefoot regions upon landing. The sequential estimation technique revealed a five-eight trial range to achieve a stable mean across all plantar loading variables, whereas ICC analysis was insensitive to inter-trial differences of repeated lay-up performances. Future studies and performance evaluation protocols on plantar loading during basketball lay-ups should include at least eight trials to ensure that the measurements obtained are sufficiently stable.

  9. A review of research in rotor loads

    NASA Technical Reports Server (NTRS)

    Bousman, William G.; Mantay, Wayne R.

    1988-01-01

    The research accomplished in the area of rotor loads over the last 13 to 14 years is reviewed. The start of the period examined is defined by the 1973 AGARD Milan conference and the 1974 hypothetical rotor comparison. The major emphasis of the review is research performed by the U.S. Army and NASA at their laboratories and/or by the industry under government contract. For the purpose of this review, two main topics are addressed: rotor loads prediction and means of rotor loads reduction. A limited discussion of research in gust loads and maneuver loads is included. In the area of rotor loads predictions, the major problem areas are reviewed including dynamic stall, wake induced flows, blade tip effects, fuselage induced effects, blade structural modeling, hub impedance, and solution methods. It is concluded that the capability to predict rotor loads has not significantly improved in this time frame. Future progress will require more extensive correlation of measurements and predictions to better understand the causes of the problems, and a recognition that differences between theory and measurement have multiple sources, yet must be treated as a whole. There is a need for high-quality data to support future research in rotor loads, but the resulting data base must not be seen as an end in itself. It will be useful only if it is integrated into firm long-range plans for the use of the data.

  10. Statistics concerning the Apollo command module water landing, including the probability of occurrence of various impact conditions, sucessful impact, and body X-axis loads

    NASA Technical Reports Server (NTRS)

    Whitnah, A. M.; Howes, D. B.

    1971-01-01

    Statistical information for the Apollo command module water landings is presented. This information includes the probability of occurrence of various impact conditions, a successful impact, and body X-axis loads of various magnitudes.

  11. Collectively loading programs in a multiple program multiple data environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aho, Michael E.; Attinella, John E.; Gooding, Thomas M.

    Techniques are disclosed for loading programs efficiently in a parallel computing system. In one embodiment, nodes of the parallel computing system receive a load description file which indicates, for each program of a multiple program multiple data (MPMD) job, nodes which are to load the program. The nodes determine, using collective operations, a total number of programs to load and a number of programs to load in parallel. The nodes further generate a class route for each program to be loaded in parallel, where the class route generated for a particular program includes only those nodes on which the programmore » needs to be loaded. For each class route, a node is selected using a collective operation to be a load leader which accesses a file system to load the program associated with a class route and broadcasts the program via the class route to other nodes which require the program.« less

  12. Determination of instream metal loads using tracer-injection and synoptic-sampling techniques, Wightman Fork, southwestern Colorado, July 1999

    USGS Publications Warehouse

    Ortiz, Roderick F.

    2001-01-01

    In July 1999, a tracer-injection study was conducted concurrently with synoptic sampling to generate mass-load profiles in Wightman Fork near the Summitville Mine site. The mine site is located in the San Juan Mountains of southwestern Colorado at an elevation of about 3,500 meters above sea level. Metal loads increased substantially along the 2,815-meter study reach along the boundary of the mine site. Spatial determinations of dissolved aluminum, copper, iron, manganese, and zinc loads were used to identify potential source areas to the stream. Overall, four source areas appeared to contribute most of the specific load at the end of the study reach. One source area was along a 60-meter reach downgradient from the toe of the North Waste Dump that generally corresponded to a region of radial faults. Another source area was a short reach that included inputs from the Summitville Water Treatment Facility and the Pump House Fault. In July 1999, seepage from the Summitville Dam Impoundment was a substantial contributor of metal load at the end of the study reach. Finally, the metal load contributed along a 60-meter reach that included Cropsy Creek is considered a substantial source of metal load to Wightman Fork.

  13. Augmentation of the space station module power management and distribution breadboard

    NASA Technical Reports Server (NTRS)

    Walls, Bryan; Hall, David K.; Lollar, Louis F.

    1991-01-01

    The space station module power management and distribution (SSM/PMAD) breadboard models power distribution and management, including scheduling, load prioritization, and a fault detection, identification, and recovery (FDIR) system within a Space Station Freedom habitation or laboratory module. This 120 VDC system is capable of distributing up to 30 kW of power among more than 25 loads. In addition to the power distribution hardware, the system includes computer control through a hierarchy of processes. The lowest level consists of fast, simple (from a computing standpoint) switchgear that is capable of quickly safing the system. At the next level are local load center processors, (LLP's) which execute load scheduling, perform redundant switching, and shed loads which use more than scheduled power. Above the LLP's are three cooperating artificial intelligence (AI) systems which manage load prioritizations, load scheduling, load shedding, and fault recovery and management. Recent upgrades to hardware and modifications to software at both the LLP and AI system levels promise a drastic increase in speed, a significant increase in functionality and reliability, and potential for further examination of advanced automation techniques. The background, SSM/PMAD, interface to the Lewis Research Center test bed, the large autonomous spacecraft electrical power system, and future plans are discussed.

  14. Comparison of Water-Load Distributions Obtained during Seaplane Landings with Bureau of Aeronautics Specifications. TED No. NACA 2413

    NASA Technical Reports Server (NTRS)

    Smiley, Robert F.; Haines, Gilbert A.

    1949-01-01

    Bureau of Aeronautics Design Specifications SS-IC-2 for water loads in sheltered water are compared with experimental water loads obtained during a full--scale landing investigation. This investigation was conducted with a JRS-1 flying boat which has a 20 degrees dead-rise V-bottom with a partial chine flare. The range of landing conditions included airspeeds between 88 and 126 feet per second, sinking speeds between 1.6 and 9.1 feet per second, flight angles less than 6 degrees, and trims between 2 degrees and 12 degrees. Landings were moderate and were made in calm water. Measurements were obtained of maximum over-all loads, maximum pitching moments, and pressure distributions. Maximum experimental loads include over-all load factors of 2g, moments of 128,000 pound-feet, and maximum local pressures greater than 40 pounds per square inch. Experimental over-all loads are approximately one-half the design values, while local pressures are of the same order as or larger than pressures calculated from specifications for plating, stringer, floor, and frame design. The value of this comparison is limited, to some extent, by the moderate conditions of the test and by the necessary simplifying assumptions used in comparing the specifications with the experimental loads.

  15. Thermal elastohydrodynamic lubrication of spur gears

    NASA Technical Reports Server (NTRS)

    Wang, K. L.; Cheng, H. S.

    1980-01-01

    An analysis and computer program called TELSGE were developed to predict the variations of dynamic load, surface temperature, and lubricant film thickness along the contacting path during the engagement of a pair of involute spur gears. The analysis of dynamic load includes the effect of gear inertia, the effect of load sharing of adjacent teeth, and the effect of variable tooth stiffness which are obtained by a finite-element method. Results obtained from TELSGE for the dynamic load distributions along the contacting path for various speeds of a pair of test gears show patterns similar to that observed experimentally. Effects of damping ratio, contact ratio, tip relief, and tooth error on the dynamic load were examined. In addition, two dimensionless charts are included for predicting the maximum equilibrium surface temperature, which can be used to estimate directly the lubricant film thickness based on well established EHD analysis.

  16. Recent advances in the modelling of crack growth under fatigue loading conditions

    NASA Technical Reports Server (NTRS)

    Dekoning, A. U.; Tenhoeve, H. J.; Henriksen, T. K.

    1994-01-01

    Fatigue crack growth associated with cyclic (secondary) plastic flow near a crack front is modelled using an incremental formulation. A new description of threshold behaviour under small load cycles is included. Quasi-static crack extension under high load excursions is described using an incremental formulation of the R-(crack growth resistance)- curve concept. The integration of the equations is discussed. For constant amplitude load cycles the results will be compared with existing crack growth laws. It will be shown that the model also properly describes interaction effects of fatigue crack growth and quasi-static crack extension. To evaluate the more general applicability the model is included in the NASGRO computer code for damage tolerance analysis. For this purpose the NASGRO program was provided with the CORPUS and the STRIP-YIELD models for computation of the crack opening load levels. The implementation is discussed and recent results of the verification are presented.

  17. Effect of load transients on SOFC operation—current reversal on loss of load

    NASA Astrophysics Data System (ADS)

    Gemmen, Randall S.; Johnson, Christopher D.

    The dynamics of solid oxide fuel cell (SOFC) operation have been considered previously, but mainly through the use of one-dimensional codes applied to co-flow fuel cell systems. In this paper several geometries are considered, including cross-flow, co-flow, and counter-flow. The details of the model are provided, and the model is compared with some initial experimental data. For parameters typical of SOFC operation, a variety of transient cases are investigated, including representative load increase and decrease and system shutdown. Of particular note for large load decrease conditions (e.g., shutdown) is the occurrence of reverse current over significant portions of the cell, starting from the moment of load loss up to the point where equilibrated conditions again provide positive current. Consideration is given as to when such reverse current conditions might most significantly impact the reliability of the cell.

  18. Ureaplasma urealyticum and U. parvum in sexually active women attending public health clinics in Brazil.

    PubMed

    Lobão, T N; Campos, G B; Selis, N N; Amorim, A T; Souza, S G; Mafra, S S; Pereira, L S; Dos Santos, D B; Figueiredo, T B; Marques, L M; Timenetsky, J

    2017-08-01

    Ureaplasma urealyticum and U. parvum have been associated with genital infections. The purpose of this study was to detect the presence of ureaplasmas and other sexually transmitted infections in sexually active women from Brazil and relate these data to demographic and sexual health, and cytokines IL-6 and IL-1β. Samples of cervical swab of 302 women were examined at the Family Health Units in Vitória da Conquista. The frequency of detection by conventional PCR was 76·2% for Mollicutes. In qPCR, the frequency found was 16·6% for U. urealyticum and 60·6% U. parvum and the bacterial load of these microorganisms was not significantly associated with signs and symptoms of genital infection. The frequency found for Trichomonas vaginalis, Neisseria gonorrhoeae, Gardnerella vaginalis and Chlamydia trachomatis was 3·0%, 21·5%, 42·4% and 1·7%, respectively. Higher levels of IL-1β were associated with control women colonized by U. urealyticum and U. parvum. Increased levels of IL-6 were associated with women who exhibited U. parvum. Sexually active women, with more than one sexual partner in the last 3 months, living in a rural area were associated with increased odds of certain U. parvum serovar infection.

  19. Serum cholecystokinin and neurotensin during follow-up of pancreas, prostate and medullary thyroid tumors.

    PubMed

    Pichon, M F; Coquin, G; Fauveau, C; Rey, A

    1999-01-01

    Growth of pancreatic carcinoma cells is stimulated by cholecystokinin (CCK) and neurotensin (NT). Prostatic carcinoma cells can secrete neurotensin. The CCK gene has been described in thyroid medullary carcinomas (MCT). Serum CCK and NT were measured by RIAs during monitoring of 19 pancreas tumours, 10 prostate adenocarcinomas and 10 thyroid medullary cancers (MCT). No correlations were found between CCK and NT in the three tumour types, nor with CA 19.9, PSA, CEA or calcitonin. In pancreas adenocarcinomas (n = 12), initial median CCK was > 8pg/ml (non significant differences between stages T, N or M). Median NT was > 80 pg/ml in all but M0 and stage I-II cases, and significantly higher in M1 and stages IV (P = 0.002). Non significant differences were found for CCK and NT according to clinical stages. In prostate cancers, median CCK was significantly more elevated after relapse (P = 0.040). Median NT was significantly more elevated in disease-free patients (P = 0.04). In MCT, CCK and NT were not related to clinical stages. In pancreas and prostate cancers serum CCK may follow tumour load and disease progression. NT was lower in progressive disease. The contribution of these peptides in human tumour growth, since they may have therapeutic implication, warrants further investigation.

  20. 7 CFR 1710.206 - Approval requirements for load forecasts prepared pursuant to approved load forecast work plans.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... effects on electric revenues caused by competition from alternative energy sources or other electric... uncertainty or alternative futures that may determine the borrower's actual loads. Examples of economic... basis. Include alternative futures, as applicable. This summary shall be designed to accommodate the...

  1. 7 CFR 1710.206 - Approval requirements for load forecasts prepared pursuant to approved load forecast work plans.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... effects on electric revenues caused by competition from alternative energy sources or other electric... uncertainty or alternative futures that may determine the borrower's actual loads. Examples of economic... basis. Include alternative futures, as applicable. This summary shall be designed to accommodate the...

  2. 7 CFR 1710.206 - Approval requirements for load forecasts prepared pursuant to approved load forecast work plans.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... effects on electric revenues caused by competition from alternative energy sources or other electric... uncertainty or alternative futures that may determine the borrower's actual loads. Examples of economic... basis. Include alternative futures, as applicable. This summary shall be designed to accommodate the...

  3. 7 CFR 1710.206 - Approval requirements for load forecasts prepared pursuant to approved load forecast work plans.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... effects on electric revenues caused by competition from alternative energy sources or other electric... uncertainty or alternative futures that may determine the borrower's actual loads. Examples of economic... basis. Include alternative futures, as applicable. This summary shall be designed to accommodate the...

  4. Smart Grid | Climate Neutral Research Campuses | NREL

    Science.gov Websites

    begun to build smart grids. Most operate electricity grids that include power generation; load control plant managers use these communications for energy management and load shedding, which are among the top familiar with equipment interoperability, central dispatch, and load shedding. These are common in smart

  5. 10 CFR 434.201 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... includes any non-heating season pilot input loss. Area of the space (A): the horizontal lighted area of a... doors of a building. Integrated part-load value (IPLV): a single-number figure of merit based on part-load EER or COP expressing part-load efficiency for air-conditioning and heat pump equipment on the...

  6. Combining ascent loads

    NASA Technical Reports Server (NTRS)

    Houbolt, J. C.

    1972-01-01

    Criteria and guidelines are presented for combining loads that develop during the ascent phase of a space flight. The primary load-caring structure is discussed including the basic tank and interconnecting members, engine support mounts and connections to tank structure, transition structures between stages, payload shrouds, and the basic support points at separation planes.

  7. 29 CFR 1926.1431 - Hoisting personnel.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... hook, load line and rigging) must not exceed 50 percent of the rated capacity for the radius and... pursuant to paragraph (b)(2) of this section, the total load (including the hook, load line, rigging and... number required to perform the work, whichever is less. (g) Attachment and rigging. (1) Hooks and other...

  8. 29 CFR 1926.1431 - Hoisting personnel.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... hook, load line and rigging) must not exceed 50 percent of the rated capacity for the radius and... pursuant to paragraph (b)(2) of this section, the total load (including the hook, load line, rigging and... number required to perform the work, whichever is less. (g) Attachment and rigging—(1) Hooks and other...

  9. EVALUATION OF SAMPLING FREQUENCIES REQUIRED TO ESTIMATE NUTRIENT AND SUSPENDED SEDIMENT LOADS IN LARGE RIVERS

    EPA Science Inventory

    Nutrients and suspended sediments in streams and large rivers are two major issues facing state and federal agencies. Accurate estimates of nutrient and sediment loads are needed to assess a variety of important water-quality issues including total maximum daily loads, aquatic ec...

  10. Aggregate Load Controllers and Associated Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chassin, David P.

    Aggregate load controllers and associated methods are described. According to one aspect, a method of operating an aggregate load controller includes using an aggregate load controller having an initial state, applying a stimulus to a plurality of thermostatic controllers which are configured to control a plurality of respective thermostatic loads which receive electrical energy from an electrical utility to operate in a plurality of different operational modes, accessing data regarding a response of the thermostatic loads as a result of the applied stimulus, using the data regarding the response, determining a value of at least one design parameter of themore » aggregate load controller, and using the determined value of the at least one design parameter, configuring the aggregate load controller to control amounts of the electrical energy which are utilized by the thermostatic loads.« less

  11. Reparo de aneurisma de artéria ilíaca roto em criança

    PubMed Central

    Hoshiko, Fernando Massaru; Zampieri, Elisa Helena Subtil; Dalio, Marcelo Bellini; Dezotti, Nei Rodrigues Alves; Joviliano, Edwaldo Edner

    2017-01-01

    Resumo Relatamos o caso de uma menina de 12 anos que deu entrada na unidade de emergência com quadro de abdome agudo hemorrágico, massa abdominal pulsátil e instabilidade hemodinâmica. Confirmado o diagnóstico de aneurisma roto de artéria ilíaca direita, foi realizada correção cirúrgica de emergência por reparo aberto com reconstrução extra-anatômica, utilizando enxerto sintético de fino calibre, compatível com a anatomia. O tratamento foi bem-sucedido e a criança apresentou evolução favorável em curto prazo.

  12. Transient Two-Dimensional Analysis of Side Load in Liquid Rocket Engine Nozzles

    NASA Technical Reports Server (NTRS)

    Wang, Ten-See

    2004-01-01

    Two-dimensional planar and axisymmetric numerical investigations on the nozzle start-up side load physics were performed. The objective of this study is to develop a computational methodology to identify nozzle side load physics using simplified two-dimensional geometries, in order to come up with a computational strategy to eventually predict the three-dimensional side loads. The computational methodology is based on a multidimensional, finite-volume, viscous, chemically reacting, unstructured-grid, and pressure-based computational fluid dynamics formulation, and a transient inlet condition based on an engine system modeling. The side load physics captured in the low aspect-ratio, two-dimensional planar nozzle include the Coanda effect, afterburning wave, and the associated lip free-shock oscillation. Results of parametric studies indicate that equivalence ratio, combustion and ramp rate affect the side load physics. The side load physics inferred in the high aspect-ratio, axisymmetric nozzle study include the afterburning wave; transition from free-shock to restricted-shock separation, reverting back to free-shock separation, and transforming to restricted-shock separation again; and lip restricted-shock oscillation. The Mach disk loci and wall pressure history studies reconfirm that combustion and the associated thermodynamic properties affect the formation and duration of the asymmetric flow.

  13. Passive microfluidic array card and reader

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dugan, Lawrence Christopher; Coleman, Matthew A

    A microfluidic array card and reader system for analyzing a sample. The microfluidic array card includes a sample loading section for loading the sample onto the microfluidic array card, a multiplicity of array windows, and a transport section or sections for transporting the sample from the sample loading section to the array windows. The microfluidic array card reader includes a housing, a receiving section for receiving the microfluidic array card, a viewing section, and a light source that directs light to the array window of the microfluidic array card and to the viewing section.

  14. Wireless Power Transfer for Space Applications

    NASA Technical Reports Server (NTRS)

    Ramos, Gabriel Vazquez; Yuan, Jiann-Shiun

    2011-01-01

    This paper introduces an implementation for magnetic resonance wireless power transfer for space applications. The analysis includes an equivalent impedance study, loop material characterization, source/load resonance coupling technique, and system response behavior due to loads variability. System characterization is accomplished by executing circuit design from analytical equations and simulations using Matlab and SPICE. The theory was validated by a combination of different experiments that includes loop material consideration, resonance coupling circuits considerations, electric loads considerations and a small scale proof-of-concept prototype. Experiment results shows successful wireless power transfer for all the cases studied. The prototype provided about 4.5 W of power to the load at a separation of -5 cm from the source using a power amplifier rated for 7 W.

  15. Effects of Backpack Frame Length, Pack Load, and Participation Time on the Physical Performance of Men and Women

    DTIC Science & Technology

    1983-08-01

    procedures and results for this project on the Biomechanics of Load Carrying Behavior. The work was formulated and directed by Drs. Carolyn K. Bensel...The first of these loads had a mass of approximately 26 kg, including all clothing and equipment worn or carried by the subject, and served as a...rifle, which weighed 3.17 kg, and the ALICE load carrying system. The pack, which weighed 1.10 kg, was loaded with Army clothing and equipment items

  16. Sea level side loads in high-area-ratio rocket engines

    NASA Technical Reports Server (NTRS)

    Nave, L. H.; Coffey, G. A.

    1973-01-01

    An empirical separation and side load model to obtain applied aerodynamic loads has been developed based on data obtained from full-scale J-2S (265K-pound-thrust engine with an area ratio of 40:1) engine and model testing. Experimental data include visual observations of the separation patterns that show the dynamic nature of the separation phenomenon. Comparisons between measured and applied side loads are made. Correlations relating the separation location to the applied side loads and the methods used to determine the separation location are given.

  17. Overview of the 6 Meter HIAD Inflatable Structure and Flexible TPS Static Load Test Series

    NASA Technical Reports Server (NTRS)

    Swanson, Greg; Kazemba, Cole; Johnson, Keith; Calomino, Anthony; Hughes, Steve; Cassell, Alan; Cheatwood, Neil

    2014-01-01

    To support NASAs long term goal of landing humans on Mars, technologies which enable the landing of heavy payloads are being developed. Current entry, decent, and landing technologies are not practical for this class of payloads due to geometric constraints dictated by current launch vehicle fairing limitations. Therefore, past and present technologies are now being explored to provide a mass and volume efficient solution to atmospheric entry, including Hypersonic Inflatable Aerodynamic Decelerators (HIADs). At the beginning of 2014, a 6m HIAD inflatable structure with an integrated flexible thermal protection system (TPS) was subjected to a static load test series to verify the designs structural performance. The 6m HIAD structure was constructed in a stacked toroid configuration using nine inflatable torus segments composed of fiber reinforced thin films, which were joined together using adhesives and high strength textile woven structural straps to help distribute the loads throughout the inflatable structure. The 6m flexible TPS was constructed using multiple layers of high performance materials to protect the inflatable structure from heat loads that would be seen during atmospheric entry. To perform the static load test series, a custom test fixture was constructed. The fixture consisted of a structural tub rim with enough height to allow for displacement of the inflatable structure as loads were applied. The bottom of the tub rim had an airtight seal with the floor. The centerbody of the inflatable structure was attached to a pedestal mount as seen in Figure 1. Using an impermeable membrane seal draped over the test article, partial vacuum was pulled beneath the HIAD, resulting in a uniform static pressure load applied to the outer surface. During the test series an extensive amount of instrumentation was used to provide many data sets including: deformed shape, shoulder deflection, strap loads, cord loads, inflation pressures, and applied static load.In this overview, the 6m HIAD static load test series will be discussed in detail, including the 6m HIAD inflatable structure and flexible TPS design, test setup and execution, and finally initial results and conclusions from the test series.

  18. Effect of extended tooth contact on the modeling of spur gear transmissions

    NASA Technical Reports Server (NTRS)

    Oswald, Fred B.; Coy, John J.; Lin, Hsiang Hsi; Wang, Jifeng

    1993-01-01

    In some gear dynamic models, the effect of tooth flexibility is ignored when the model determines which pairs of teeth are in contact. Deflection of loaded teeth is not introduced until the equations of motion are solved. This means the zone of tooth contact and average tooth meshing stiffness are underestimated and the individual tooth load is overstated, especially for heavily-loaded gears. The static transmission error and dynamic load of heavily-loaded, low-contact-ratio spur gears is compared with this effect both neglected and included. Neglecting the effect yields an underestimate of resonance speeds and an overestimate of the dynamic load.

  19. Dynamic load-sharing characteristic analysis of face gear power-split gear system based on tooth contact characteristics

    NASA Astrophysics Data System (ADS)

    Dong, Hao; Hu, Yahui

    2018-04-01

    The bend-torsion coupling dynamics load-sharing model of the helicopter face gear split torque transmission system is established by using concentrated quality standard, to analyzing the dynamic load-sharing characteristic. The mathematical models include nonlinear support stiffness, time-varying meshing stiffness, damping, gear backlash. The results showed that the errors collectively influenced the load sharing characteristics, only reduce a certain error, it is never fully reached the perfect loading sharing characteristics. The system load-sharing performance can be improved through floating shaft support. The above-method will provide a theoretical basis and data support for its dynamic performance optimization design.

  20. Global Earth Response to Loading by Ocean Tide Models

    NASA Technical Reports Server (NTRS)

    Estes, R. H.; Strayer, J. M.

    1979-01-01

    Mathematical and programming techniques to numerically calculate Earth response to global semidiurnal and diurnal ocean tide models were developed. Global vertical crustal deformations were evaluated for M sub 2, S sub 2, N sub 2, K sub 2, K sub 1, O sub 1, and P sub 1 ocean tide loading, while horizontal deformations were evaluated for the M sub 2 tidal load. Tidal gravity calculations were performed for M sub 2 tidal loads, and strain tensor elements were evaluated for M sub 2 loads. The M sub 2 solution used for the ocean tide included the effects of self-gravitation and crustal loading.

  1. SSME/side loads analysis for flight configuration, revision A. [structural analysis of space shuttle main engine under side load excitation

    NASA Technical Reports Server (NTRS)

    Holland, W.

    1974-01-01

    This document describes the dynamic loads analysis accomplished for the Space Shuttle Main Engine (SSME) considering the side load excitation associated with transient flow separation on the engine bell during ground ignition. The results contained herein pertain only to the flight configuration. A Monte Carlo procedure was employed to select the input variables describing the side load excitation and the loads were statistically combined. This revision includes an active thrust vector control system representation and updated orbiter thrust structure stiffness characteristics. No future revisions are planned but may be necessary as system definition and input parameters change.

  2. JT9D engine diagnostics. Task 2: Feasibility study of measuring in-service flight loads. [747 aircraft performance

    NASA Technical Reports Server (NTRS)

    Kafka, P. G.; Skibo, M. A.; White, J. L.

    1977-01-01

    The feasibility of measuring JT9D propulsion system flight inertia loads on a 747 airplane is studied. Flight loads background is discussed including the current status of 747/JT9D loads knowledge. An instrumentation and test plan is formulated for an airline-owned in-service airplane and the Boeing-owned RA001 test airplane. Technical and cost comparisons are made between these two options. An overall technical feasibility evaluation is made and a cost summary presented. Conclusions and recommendations are presented in regard to using existing inertia loads data versus conducting a flight test to measure inertia loads.

  3. A calibration procedure for load cells to improve accuracy of mini-lysimeters in monitoring evapotranspiration

    NASA Astrophysics Data System (ADS)

    Misra, R. K.; Padhi, J.; Payero, J. O.

    2011-08-01

    SummaryWe used twelve load cells (20 kg capacity) in a mini-lysimeter system to measure evapotranspiration simultaneously from twelve plants growing in separate pots in a glasshouse. A data logger combined with a multiplexer was used to connect all load cells with the full-bridge excitation mode to acquire load-cell signal. Each load cell was calibrated using fixed load within the range of 0-0.8 times the full load capacity of load cells. Performance of all load cells was assessed on the basis of signal settling time, excitation compensation, hysteresis and temperature. Final calibration of load cells included statistical consideration of these effects to allow prediction of lysimeter weights and evapotranspiration over short-time intervals for improved accuracy and sustained performance. Analysis of the costs for the mini-lysimeter system indicates that evapotranspiration can be measured economically at a reasonable accuracy and sufficient resolution with robust method of load-cell calibration.

  4. Series-counterpulse repetitive-pulse inductive storage circuit

    DOEpatents

    Honig, Emanuel M.

    1986-01-01

    A high-power series-counterpulse repetitive-pulse inductive energy storage and transfer circuit includes an opening switch, a main energy storage coil, and a counterpulse capacitor. The load pulse is initiated simultaneously with the initiation of the counterpulse which is used to turn the opening switch off. There is no delay from command to output pulse. During the load pulse, the counterpulse capacitor is first discharged and then recharged in the opposite polarity with sufficient energy to accomplish the load counterpulse which terminates the load pulse and turns the load switch off. When the main opening switch is triggered closed again to terminate the load pulse, the counterpulse capacitor discharges in the reverse direction through the load switch and through the load, causing a rapid, sharp cutoff of the load pulse as well as recovering any energy remaining in the load inductance. The counterpulse capacitor is recharged to its original condition by the main energy storage coil after the load pulse is over, not before it begins.

  5. High fidelity computational characterization of the mechanical response of thermally aged polycarbonate

    NASA Astrophysics Data System (ADS)

    Zhang, Zesheng; Zhang, Lili; Jasa, John; Li, Wenlong; Gazonas, George; Negahban, Mehrdad

    2017-07-01

    A representative all-atom molecular dynamics (MD) system of polycarbonate (PC) is built and conditioned to capture and predict the behaviours of PC in response to a broad range of thermo-mechanical loadings for various thermal aging. The PC system is constructed to have a distribution of molecular weights comparable to a widely used commercial PC (LEXAN 9034), and thermally conditioned to produce models for aged and unaged PC. The MD responses of these models are evaluated through comparisons to existing experimental results carried out at much lower loading rates, but done over a broad range of temperatures and loading modes. These experiments include monotonic extension/compression/shear, unilaterally and bilaterally confined compression, and load-reversal during shear. It is shown that the MD simulations show both qualitative and quantitative similarity with the experimental response. The quantitative similarity is evaluated by comparing the dilatational response under bilaterally confined compression, the shear flow viscosity and the equivalent yield stress. The consistency of the in silico response to real laboratory experiments strongly suggests that the current PC models are physically and mechanically relevant and potentially can be used to investigate thermo-mechanical response to loading conditions that would not easily be possible. These MD models may provide valuable insight into the molecular sources of certain observations, and could possibly offer new perspectives on how to develop constitutive models that are based on better understanding the response of PC under complex loadings. To this latter end, the models are used to predict the response of PC to complex loading modes that would normally be difficult to do or that include characteristics that would be difficult to measure. These include the responses of unaged and aged PC to unilaterally confined extension/compression, cyclic uniaxial/shear loadings, and saw-tooth extension/compression/shear.

  6. LOADING SIMULATION PROGRAM C

    EPA Pesticide Factsheets

    LSPC is the Loading Simulation Program in C++, a watershed modeling system that includes streamlined Hydrologic Simulation Program Fortran (HSPF) algorithms for simulating hydrology, sediment, and general water quality

  7. Advanced Composites for Air and Ground Vehicles

    DTIC Science & Technology

    2015-08-01

    Engineering A, 429: 225–235. [2] Sharma, S. (2010). “Process development issues of glass-carbon hybrid- reinforced polymer composite wind turbine blades...with numerous possibilities including “zero- slip ” behavior, reduced/delayed delaminations under load, and enhanced load-carrying capacities relative to...pads having a Shore-A durometer of 55 and thickness of 3 mm were glued to the loading block to prevent slipping . The loading and support bars were

  8. Residential Simulation Tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Starke, Michael R; Abdelaziz, Omar A; Jackson, Rogerick K

    Residential Simulation Tool was developed to understand the impact of residential load consumption on utilities including the role of demand response. This is complicated as many different residential loads exist and are utilized for different purposes. The tool models human behavior and contributes this to load utilization, which contributes to the electrical consumption prediction by the tool. The tool integrates a number of different databases from Department of Energy and other Government websites to support the load consumption prediction.

  9. Physics Division annual report 2004.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glover, J.

    2006-04-06

    This report highlights the research performed in 2004 in the Physics Division of Argonne National Laboratory. The Division's programs include operation of ATLAS as a national user facility, nuclear structure and reaction research, nuclear theory, medium energy nuclear research and accelerator research and development. The intellectual challenges of this research represent some of the most fundamental challenges in modern science, shaping our understanding of both tiny objects at the center of the atom and some of the largest structures in the universe. A great strength of these efforts is the critical interplay of theory and experiment. Notable results in researchmore » at ATLAS include a measurement of the charge radius of He-6 in an atom trap and its explanation in ab-initio calculations of nuclear structure. Precise mass measurements on critical waiting point nuclei in the rapid-proton-capture process set the time scale for this important path in nucleosynthesis. An abrupt fall-off was identified in the subbarrier fusion of several heavy-ion systems. ATLAS operated for 5559 hours of research in FY2004 while achieving 96% efficiency of beam delivery for experiments. In Medium Energy Physics, substantial progress was made on a long-term experiment to search for the violation of time-reversal invariance using trapped Ra atoms. New results from HERMES reveal the influence of quark angular momentum. Experiments at JLAB search for evidence of color transparency in rho-meson production and study the EMC effect in helium isotopes. New theoretical results include a Poincare covariant description of baryons as composites of confined quarks and non-point-like diquarks. Green's function Monte Carlo techniques give accurate descriptions of the excited states of light nuclei and these techniques been extended to scattering states for astrophysics studies. A theoretical description of the phenomena of proton radioactivity has been extended to triaxial nuclei. Argonne continues to lead in the development and exploitation of the new technical concepts that will truly make RIA, in the words of NSAC, ''the world-leading facility for research in nuclear structure and nuclear astrophysics''. The performance standards for new classes of superconducting cavities continue to increase. Driver linac transients and faults have been analyzed to understand reliability issues and failure modes. Liquid-lithium targets were shown to successfully survive the full-power deposition of a RIA beam. Our science and our technology continue to point the way to this major advance. It is a tremendously exciting time in science for RIA holds the keys to unlocking important secrets of nature. The work described here shows how far we have come and makes it clear we know the path to meet these intellectual challenges. The great progress that has been made in meeting the exciting intellectual challenges of modern nuclear physics reflects the talents and dedication of the Physics Division staff and the visitors, guests and students who bring so much to the research.« less

  10. 7 CFR 1710.206 - Approval requirements for load forecasts prepared pursuant to approved load forecast work plans.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... narrative shall address the overall approach, time periods, and expected internal and external uses of the forecast. Examples of internal uses include providing information for developing or monitoring demand side... suppliers. Examples of external uses include meeting state and Federal regulatory requirements, obtaining...

  11. Cognitive Load Theory and the Acquisition of Complex Cognitive Skills in the Elderly: Towards an Integrative Framework.

    ERIC Educational Resources Information Center

    Van Gerven, Pascal W. M.; Paas, Fred G. W. C.; Van Merrienboer, Jeroen J. G.; Schmidt, Henk G.

    2000-01-01

    Cognitive load (CL) theory suggests minimizing extraneous CL and maximizing germane CL in order not to overload working memory. Instructional design for older adults should therefore include goal-free problems, worked examples, and different modalities and avoid splitting attention and including redundant information. (SK)

  12. A method for communication analysis in prosthodontics.

    PubMed

    Sondell, K; Söderfeldt, B; Palmqvist, S

    1998-02-01

    Particularly in prosthodontics, in which the issues of esthetic preferences and possibilities are abundant, improved knowledge about dentist patient communication during clinical encounters is important. Because previous studies on communication used different methods and patient materials, the results are difficult to evaluate. There is, therefore, a need for methodologic development. One method that makes it possible to quantitatively describe different interaction behaviors during clinical encounters is the Roter Method of Interaction Process Analysis (RIAS). Since the method was developed in the USA for use in the medical context, a translation of the method into Swedish and a modification of the categories for use in prosthodontics were necessary. The revised manual was used to code 10 audio recordings of dentist patient encounters at a specialist clinic for prosthodontics. No major alterations of the RIAS manual were made during the translation and modification. The study shows that it is possible to distinguish patterns of communication in audio-recorded dentist patient encounters. The method also made the identification of different interaction profiles possible. These profiles distinguished well among the audio-recorded encounters. The coding procedures were tested for intra-rater reliability and found to be 97% for utterance classification and lambda = 0.76 for categorization definition. It was concluded that the revised RIAS method is applicable in communication studies in prosthodontics.

  13. Comparação entre cirurgia aberta e endovascular no tratamento do aneurisma da artéria poplítea: uma revisão

    PubMed Central

    Gonçalves, Ana Fernanda Fagundes; Pelek, Carlos Augusto; Nogueira, Lorena Slusarz; de Carvalho, Renan Francisco; Stumpf, Matheo Augusto Morandi; Gomes, Ricardo Zanetti; Kluthcovsky, Ana Claudia Garabeli Cavalli

    2018-01-01

    Resumo Os aneurismas de artéria poplítea correspondem a 70% dos aneurismas periféricos e o tratamento é cirúrgico, com controvérsias sobre os resultados da via endovascular. Este estudo objetivou realizar uma revisão da literatura sobre a comparação entre cirurgia aberta e endovascular no tratamento dos aneurismas da artéria poplítea. A pesquisa foi realizada utilizando os termos apropriados nos portais de periódicos LILACS e MEDLINE, com a seleção de 15 artigos. Um total de 5.166 procedimentos cirúrgicos foram comparados, sendo 3.930 cirurgias abertas e 1.236 cirurgias endovasculares. A cirurgia aberta com bypass venoso continua sendo o padrão-ouro. A cirurgia endovascular apresenta menor tempo de internação e é uma opção viável em pacientes eletivos, com baixa expectativa de vida, alto risco cirúrgico, comorbidades e mais idosos, desde que tenham anatomia favorável para o procedimento. Contudo, são necessários estudos de longo prazo para estabelecer os reais benefícios e indicações das duas técnicas, como o ensaio clínico randomizado controlado.

  14. Preliminary Results on the Evaluation of the Occurrence of Tetrodotoxin Associated to Marine Vibrio spp. in Bivalves from the Galician Rias (Northwest of Spain)

    PubMed Central

    Leão, Jose Manuel; Lozano-Leon, Antonio; Giráldez, Jorge; Vilariño, Óscar; Gago-Martínez, Ana

    2018-01-01

    Tetrodotoxins (TTX) are a potent group of natural neurotoxins putatively produced by symbiotic microorganisms and affecting the aquatic environment. These neurotoxins have been recently found in some species of bivalves and gastropods along the European Coasts (Greece, UK, and The Netherlands) linked to the presence of high concentrations of Vibrio, in particular Vibrio parahaemolyticus. This study is focused on the evaluation of the presence of Vibrio species and TTX in bivalves (mussels, oysters, cockles, clams, scallops, and razor clams) from Galician Rias (northwest of Spain). The detection and isolation of the major Vibrio spp. and other enterobacterial populations have been carried out with the aim of screening for the presence of the pathways genes, poliketide synthase (PKS) and non-ribosomal peptide synthetase (NRPS) possibly involved in the biosynthesis of these toxins. Samples containing Vibrio spp. were analyzed by biochemical (API20E-galery) and genetic tests (PCR-RT). These samples were then screened for TTX toxicity by a neuroblastoma cell-based assay (N2a) and the presence of TTX was further confirmed by LC-MS/MS. TTX was detected in two infaunal samples. This is the first confirmation of the presence of TTX in bivalve molluscs from the Galician Rias. PMID:29509715

  15. Geochemical and geological factors controlling the spatial distribution of sulfate-methane transition zone in the Ría de Vigo (NW Spain)

    NASA Astrophysics Data System (ADS)

    Martínez-Carreño, N.; García-Gil, S.; Cartelle, V.; de Blas, E.; Ramírez-Pérez, A. M.; Insua, T. L.

    2017-05-01

    High-resolution seismic profiles, gravity core analysis and radiocarbon data have been used to identify the factors behind the methane production and free gas accumulation in the Ría de Vigo. Lithological and geochemical parameters (sulfate and methane concentration) from seventeen gravity cores were analyzed to characterize the sediment of the ria. The distribution of methane-charged sediments is mainly controlled by the quantity and quality of organic matter. Geochemical analyses reveal minimum methane concentrations ranging between 1 μM and 1 mM in sediments located outside the acoustic gas field, while gas-bearing sediments, show methane concentrations up to 5 mM. A shallowing of the sulfate-methane transition zone (SMTZ) is observed from the outer to the inner area of the ria. The presence of methane in the sulfate reduction zone (SRZ) likely to reflect the existence of methylotropic methanogenesis and/or migration processes of deeper methane gas in the sediments of the Ría de Vigo. The presence of an 'anomalous' high-sulfate concentration layer below the SMTZ in the inner and middle area of the ria, is attributed to the intrusion of sulfate-rich waters from adjacent areas that could be transported laterally through more porous layers.

  16. Radioimmunoassay for etorphine in horses with a /sup 125/I analog of etorphine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tai, C.L.; Wang, C.; Weckman, T.J.

    1988-05-01

    To improve the sensitivity and specificity of screening for etorphine in horses, an /sup 125/I-labeled etorphine analog was synthesized and an antibody to etorphine was raised in rabbits. A radioimmunoassay (RIA) for etorphine was developed, using these reagents. Bound and free /sup 125/I-labeled etorphine was separated by a double-antibody method that reduced interference from materials associated with equine urine. The /sup 125/I-labeled etorphine binding was rarely greater than 250 pg of background etorphine equivalents/ml in raw urine and was 100 pg/ml in hydrolyzed urine. The /sup 125/I-RIA was capable of detecting etorphine equivalents in urine above these background values. Etorphinemore » equivalents were detected in equine urine samples for about 7 days after 4 mares were dosed with 0.22 microgram of etorphine/kg of body weight, IV. The stability of etorphine in urine from these mares was evaluated. Urine from these dosed mares was held in constant -20 C storage, and aliquots were repeatedly frozen and thawed. When analyzed for etorphine equivalents using an /sup 125/I-RIA, etorphine and its metabolites in urine samples were stable for less than or equal to 38 days if continuously frozen and also were resistant to repeated freezing and thawing.« less

  17. Simple, rapid /sup 125/I-labeled cyclosporine double antibody/polyethylene glycol radioimmunoassay used in a pediatric cardiac transplant program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berk, L.S.; Webb, G.; Imperio, N.C.

    1986-01-01

    We modified the Sandoz cyclosporine radioimmunoassay because of our need for frequent clinical monitoring of cyclosporine drug levels in allo- and xenograft pediatric cardiac transplant patients. With application of a commercially available (/sup 125/I)cyclosporine label in place of (/sup 3/H)cyclosporine and a second antibody/polyethylene glycol (PEG) method of separation in place of charcoal separation, we simplified and enhanced the speed and precision of assay performance. Studies of 140 whole blood samples comparing this new method to the (/sup 3/H)cyclosporine radioimmunoassay (RIA) method of Berk and colleagues yielded a coefficient of correlation of 0.96 (p less than 0.00001) with means ofmore » 626 and 667 ng/ml for (/sup 3/H)RIA and (/sup 125/I)RIA, respectively, and a regression equation of y = 28 + 1.02x. The major advantages are that total assay time is reduced to approximately 1 h; (/sup 125/I)cyclosporine label is used, avoiding the problems associated with liquid scintillation counting; and precision is enhanced by separating bound and free fractions with second antibody/PEG. These modifications should provide for greater ease of assay performance and improved clinical utility of cyclosporine monitoring not only in the pediatric but also in the adult transplant patient.« less

  18. [Disclosing the work processes of the community health agents on the Family Health Strategy in Vitória (ES, Brazil)].

    PubMed

    Galavote, Heletícia Scabelo; do Prado, Thiago Nascimento; Maciel, Ethel Leonor Noia; de Cássia Duarte Lima, Rita

    2011-01-01

    The community health agent (CHA) has a singular role as a "link" between the community and the health service. The main purpose of this descriptive/qualitative study is to evaluate the production of the CHA work processes in the Family Health Strategy in the county of Vitória (ES, Brazil). The research was developed in the health region of Maruípe, a district in the county of Vitória. The researchers invited 14 CHAs to use a half structured interview based on a guide script containing 24 questions. The process of work in health was considered as "a prevention and promotion of health", and the domiciliary visits were considered as being an everyday basic activity. The CHAs withhold several interpretations concerning to the work process and associated to the concept of unit the team has. It is also possible to notice a kind of idealism of the competences concerning to the CHA work, thus, causing a feeling of impotence and limitation when facing the challenges imposed by it. It is possible to conclude that the CHA needs tools and abilities that overcome their technical knowledge in order to act in a social scope and also to deal with the health needs of each user.

  19. Hydrodynamic and shock heating instabilities of liquid metal strippers for RIA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hassanein, Ahmed

    2013-05-24

    Stripping of accelerated ions is a key problem for the design of RIA to obtain high efficiency. Thin liquid Lithium film flow is currently considered as stripper for RIA ion beams to obtain higher Z for following acceleration: in extreme case of Uranium from Z=29 to Z=60-70 (first stripper) and from Z=70 till full stripping Z=92 (second stripper). Ionization of ion occurs due to the interaction of the ion with electrons of target material (Lithium) with the loss of parts of the energy due to ionization, Q{sub U}, which is also accompanied with ionization energy losses, Q{sub Li} of themore » lithium. The resulting heat is so high that can be removed not by heat conduction but mainly by convection, i.e., flowing of liquid metal across beam spot area. The interaction of the beam with the liquid metal generates shock wave propagating along direction perpendicular to the beam as well as excites oscillations along beam direction. We studied the dynamics of these excited waves to determine conditions for film stability at the required velocities for heat removal. It will allow optimizing jet nozzle shapes and flow parameters to prevent film fragmentation and to ensure stable device operation.« less

  20. Fontes binárias supermoles de raios X

    NASA Astrophysics Data System (ADS)

    Pires, A. M.; Janot Pacheco, E.

    2003-08-01

    Estuda-se as características físicas das fontes supermoles (de raios X (SSS), utilizando dados ópticos e em altas energias, no âmbito de um trabalho de IC. Trata-se de binárias que apresentam espectro X muito mole, baixas temperaturas e altas luminosidades bolométricas. Esse sistemas são compostos por uma anã branca realizando fusão em sua superfície, a partir de matéria perdida pela estrela companheira. Os resíduos de fusão se acumulam na superfície da anã branca, e essa pode ultrapassar o limite de Chadrasekhar, produzir um colapso gravitacional, sendo esse um dos cenários propostos para as explosões de SN Ia. Apresentamos nesta comunicação o estado da arte das características físicas das fontes SSS, situando-as no âmbito das VCs. Procuramos também situar esses objetos em relação às variáveis galácticas V Sge, na medida em que os dois grupos apresentam certas caracerísticas bastante semelhantes.A metodologia adotada é aquela pedagógico-cognitiva clássica de um trabalho de IC na área de ciências exatas.

  1. Lithogenic sources, composition and intra-annual variability of suspended particulate matter supplied from rivers to the Northern Galician Rias (Bay of Biscay)

    NASA Astrophysics Data System (ADS)

    Bernárdez, Patricia; Prego, Ricardo; Filgueiras, Ana Virginia; Ospina-Álvarez, Natalia; Santos-Echeandía, Juan; Álvarez-Vázquez, Miguel Angel; Caetano, Miguel

    2017-12-01

    Scarce research about small European rivers from non-human impacted areas to determine their natural background state has been undertaken. During the annual hydrological cycle of 2008-9 the patterns of particulate supply (SPM, POC, PON, Al, Cd, Co, Cr, Cu, Fe, Ni, Pb, V, Zn) from the rivers Sor, Mera Landro, Lourido and Landoi to the Northern Galician Rias (SW Bay of Biscay) were tackled. No differences in the composition of the SPM were detected for the studied rivers regarding Al, Fe and POC but the relative percentage of particulate trace elements (PTE) discriminate the rivers. So, Cr, Co and Ni in the Lourido, and Landoi rivers, and Cu in the Mera River, are controlled by watershed minerals of Ortegal Geological Complex while for the rest rivers PTE are by granitic and Ollo de Sapo bedrock watershed. Therefore, the imprint of PTE in the parental rocks of the river basins is reflected on the coastal sediments of the Rias. The main process controlling the dynamics and variations of chemical elements in the particulate form is the river discharge. This fact exemplifies that these rivers presents a natural behavior not being highly influenced by anthropogenic activities.

  2. [Optimization on trehalose loading technique as protective conditioning for lyophilization of human platelets].

    PubMed

    Liu, Jing-Han; Zhou, Jun; Ouyang, Xi-Lin; Li, Xi-Jin; Lu, Fa-Qiang

    2005-08-01

    This study was aimed to further optimize trehalose loading technique including loading temperature, loading time, loading solution and loading concentration of trehalose, based on the established parameters. Loading efficiency in plasma was compared with that in buffer at 37 degrees C; the curves of intracellular trehalose concentration versus loading time at 37 degrees C and 16 degrees C were measured; curves of mean platelet volume (MPV) versus loading time and loading concentration were investigated and compared. According to results obtained, the loaing time, loading temperature, loading solution and trehalose concentration were ascertained for high loading efficiency of trehalose into human platelet. The results showed that the loading efficiency in plasma was markedly higher than that in buffer at 37 degrees C, the loading efficiency in plasma at 37 degrees C was significantly higher than that at 16 degrees C and reached 19.51% after loading for 4 hours, but 6.16% at 16 degrees C. MPV at 16 degrees C was increased by 43.2% than that at 37 degrees C, but had no distinct changes with loading time and loading concentration. In loading at 37 degrees C, MPV increased with loading time and loading concentration positively. Loading time and loading concentration displayed synergetic effect on MPV. MPV increased with loading time and concentration while trehalose loading concentration was above 50 mmol/L. It is concluded that the optimization parameters of trehalose loading technique are 37 degrees C (temperature), 4 hours (leading time), plasma (loading solution), 50 mmol/L (feasible trehalose concentration). The trehalose concentration can be adjusted to meet the requirement of lyophilization.

  3. Methods for computing water-quality loads at sites in the U.S. Geological Survey National Water Quality Network

    USGS Publications Warehouse

    Lee, Casey J.; Murphy, Jennifer C.; Crawford, Charles G.; Deacon, Jeffrey R.

    2017-10-24

    The U.S. Geological Survey publishes information on concentrations and loads of water-quality constituents at 111 sites across the United States as part of the U.S. Geological Survey National Water Quality Network (NWQN). This report details historical and updated methods for computing water-quality loads at NWQN sites. The primary updates to historical load estimation methods include (1) an adaptation to methods for computing loads to the Gulf of Mexico; (2) the inclusion of loads computed using the Weighted Regressions on Time, Discharge, and Season (WRTDS) method; and (3) the inclusion of loads computed using continuous water-quality data. Loads computed using WRTDS and continuous water-quality data are provided along with those computed using historical methods. Various aspects of method updates are evaluated in this report to help users of water-quality loading data determine which estimation methods best suit their particular application.

  4. Empirical Investigations of the Opportunity Limits of Automatic Residential Electric Load Shaping

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cruickshank, Robert F.; Henze, Gregor P.; Balaji, Rajagopalan

    Residential electric load shaping is often modeled as infrequent, utility-initiated, short-duration deferral of peak demand through direct load control. In contrast, modeled herein is the potential for frequent, transactive, intraday, consumer-configurable load shaping for storage-capable thermostatically controlled electric loads (TCLs), including refrigerators, freezers, and hot water heaters. Unique to this study are 28 months of 15-minute-interval observations of usage in 101 homes in the Pacific Northwest United States that specify exact start, duration, and usage patterns of approximately 25 submetered loads per home. The magnitudes of the load shift from voluntarily-participating TCL appliances are aggregated to form hourly upper andmore » lower load-shaping limits for the coordination of electrical generation, transmission, distribution, storage, and demand. Empirical data are statistically analyzed to define metrics that help quantify load-shaping opportunities.« less

  5. Empirical Investigations of the Opportunity Limits of Automatic Residential Electric Load Shaping: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cruickshank, Robert F.; Henze, Gregor P.; Balaji, Rajagopalan

    Residential electric load shaping is often modeled as infrequent, utility-initiated, short-duration deferral of peak demand through direct load control. In contrast, modeled herein is the potential for frequent, transactive, intraday, consumer-configurable load shaping for storage-capable thermostatically controlled electric loads (TCLs), including refrigerators, freezers, and hot water heaters. Unique to this study are 28 months of 15-minute-interval observations of usage in 101 homes in the Pacific Northwest United States that specify exact start, duration, and usage patterns of approximately 25 submetered loads per home. The magnitudes of the load shift from voluntarily-participating TCL appliances are aggregated to form hourly upper andmore » lower load-shaping limits for the coordination of electrical generation, transmission, distribution, storage, and demand. Empirical data are statistically analyzed to define metrics that help quantify load-shaping opportunities.« less

  6. Series-counterpulse repetitive-pulse inductive storage circuit

    DOEpatents

    Honig, E.M.

    1984-06-05

    A high-power series-counterpulse repetitive-pulse inductive energy storage and transfer circuit includes an opening switch, a main energy storage coil, and a counterpulse capacitor. The local pulse is initiated simultaneously with the initiation of the counterpulse used to turn the opening switch off. There is no delay from command to output pulse. During the load pulse, the counterpulse capacitor is automatically charged with sufficient energy to accomplish the load counterpulse which terminates the load pulse and turns the load switch off. When the main opening switch is reclosed to terminate the load pulse, the counterpulse capacitor discharges through the load, causing a rapid, sharp cutoff of the load pulse as well as recovering any energy remaining in the load inductance. The counterpulse capacitor is recharged to its original condition by the main energy storage coil after the load pulse is over, not before it begins.

  7. Commentary: Should Gender Differences Be Included in the Evolutionary Upgrade to Cognitive Load Theory?

    ERIC Educational Resources Information Center

    Bevilacqua, Andy

    2017-01-01

    Recent upgrades to cognitive load theory suggest that evolutionary processes have shaped the way that working memory processes cultural and social information. According to evolutionarily educational psychologists, some forms of information are processed with lower working memory loads than other forms. The former are evolutionarily salient and…

  8. Climate change impacts on runoff, sediment, and nutrient loads in an agricultural watershed in the Lower Mississippi River Basin

    USDA-ARS?s Scientific Manuscript database

    Projected climate change can impact various aspects of agricultural systems, including the nutrient and sediment loads exported from agricultural fields. This study evaluated the potential changes in runoff, sediment, nitrogen, and phosphorus loads using projected climate estimates from 2041 – 2070 ...

  9. 18 CFR 16.10 - Information to be provided by an applicant for new license: Filing requirements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... applicant's operating and load characteristics; and (C) The communities served or to be served, including... the contributions from the applicant's generation, purchases, and load modification measures (such as...; and (C) If load management measures are not viewed as resources, the effects of such measures on the...

  10. 18 CFR 16.10 - Information to be provided by an applicant for new license: Filing requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... applicant's operating and load characteristics; and (C) The communities served or to be served, including... the contributions from the applicant's generation, purchases, and load modification measures (such as...; and (C) If load management measures are not viewed as resources, the effects of such measures on the...

  11. 18 CFR 16.10 - Information to be provided by an applicant for new license: Filing requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... applicant's operating and load characteristics; and (C) The communities served or to be served, including... the contributions from the applicant's generation, purchases, and load modification measures (such as...; and (C) If load management measures are not viewed as resources, the effects of such measures on the...

  12. 7 CFR Exhibit J to Subpart A of... - Manufactured Home Sites, Rental Projects and Subdivisions: Development, Installation and Set-Up

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... devices adequate to resist all loads identified in the MPS. This includes resistance to ground movements, seismic shaking, potential shearing, overturning and uplift loads caused by wind. Note that anchoring..., within allowable stress and settlement limitations, all applicable loads. Any foundation and anchorage...

  13. 18 CFR 16.10 - Information to be provided by an applicant for new license: Filing requirements.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... applicant's operating and load characteristics; and (C) The communities served or to be served, including... the contributions from the applicant's generation, purchases, and load modification measures (such as...; and (C) If load management measures are not viewed as resources, the effects of such measures on the...

  14. 18 CFR 16.10 - Information to be provided by an applicant for new license: Filing requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... applicant's operating and load characteristics; and (C) The communities served or to be served, including... the contributions from the applicant's generation, purchases, and load modification measures (such as...; and (C) If load management measures are not viewed as resources, the effects of such measures on the...

  15. Ignition potential of muzzle-loading firearms: An exploratory investigation

    Treesearch

    David V. Haston; Mark A. Finney; Andy Horcher; Philip A. Yates; Kahlil Detrich

    2009-01-01

    The National Technology and Development Program of the Forest Service, U.S. Department of Agriculture, was asked to conduct an exploratory study on the ignition potential of muzzle-loading firearms. The five independent variables investigated include projectile type, powder type, powder load, patch thickness, and patch lubricant treatment. Indoor testing was performed...

  16. Student Teacher Challenges: Using the Cognitive Load Theory as an Explanatory Lens

    ERIC Educational Resources Information Center

    Moos, Daniel C.; Pitton, Debra

    2014-01-01

    Cognitive load theory (CLT) can explain the challenges faced by student teachers. This study, guided by the CLT, included 26 pre-service teachers. Participants completed a cognitive load self-report questionnaire and were interviewed at two points during their student teaching. Results revealed that student teachers decreased mental effort related…

  17. Load-embedded inertial measurement unit reveals lifting performance.

    PubMed

    Tammana, Aditya; McKay, Cody; Cain, Stephen M; Davidson, Steven P; Vitali, Rachel V; Ojeda, Lauro; Stirling, Leia; Perkins, Noel C

    2018-07-01

    Manual lifting of loads arises in many occupations as well as in activities of daily living. Prior studies explore lifting biomechanics and conditions implicated in lifting-induced injuries through laboratory-based experimental methods. This study introduces a new measurement method using load-embedded inertial measurement units (IMUs) to evaluate lifting tasks in varied environments outside of the laboratory. An example vertical load lifting task is considered that is included in an outdoor obstacle course. The IMU data, in the form of the load acceleration and angular velocity, is used to estimate load vertical velocity and three lifting performance metrics: the lifting time (speed), power, and motion smoothness. Large qualitative differences in these parameters distinguish exemplar high and low performance trials. These differences are further supported by subsequent statistical analyses of twenty three trials (including a total of 115 total lift/lower cycles) from fourteen healthy participants. Results reveal that lifting time is strongly correlated with lifting power (as expected) but also correlated with motion smoothness. Thus, participants who lift rapidly do so with significantly greater power using motions that minimize motion jerk. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Using a latent variable model with non-constant factor loadings to examine PM2.5 constituents related to secondary inorganic aerosols.

    PubMed

    Zhang, Zhenzhen; O'Neill, Marie S; Sánchez, Brisa N

    2016-04-01

    Factor analysis is a commonly used method of modelling correlated multivariate exposure data. Typically, the measurement model is assumed to have constant factor loadings. However, from our preliminary analyses of the Environmental Protection Agency's (EPA's) PM 2.5 fine speciation data, we have observed that the factor loadings for four constituents change considerably in stratified analyses. Since invariance of factor loadings is a prerequisite for valid comparison of the underlying latent variables, we propose a factor model that includes non-constant factor loadings that change over time and space using P-spline penalized with the generalized cross-validation (GCV) criterion. The model is implemented using the Expectation-Maximization (EM) algorithm and we select the multiple spline smoothing parameters by minimizing the GCV criterion with Newton's method during each iteration of the EM algorithm. The algorithm is applied to a one-factor model that includes four constituents. Through bootstrap confidence bands, we find that the factor loading for total nitrate changes across seasons and geographic regions.

  19. On ambiente de binárias de pequena massa em formação: o caso do glóbulo cometário CG30 e IRAS08076-3556

    NASA Astrophysics Data System (ADS)

    Hickel, G. R.; Vilas-Boas, J. W. S.

    2003-08-01

    Neste trabalho, combinamos observações de polarização linear no óptico (banda R), dados no infravermelho distante (IRAS) e observações de transições moleculares em radiofreqüências (CO e espécies isotópicas, HCN e HCO+) para analisar o glóbulo cometário (GC) CG30 (na região da IRAS Vela Shell), que apresenta objetos Herbig-Haro e ejeções de matéria, além de uma fonte pontual IRAS em seu interior. Os objetivos deste estudo são: determinar a eficiência de formação estelar nos glóbulos cometários, através da relação entre a massa total do GC e da massa das estrelas em formação; determinar como o campo magnético influencia na formação de estrelas no interior destes objetos; e analisar as modificações que ejeções de matéria de estrelas em formação causam no gás e no campo magnético dos GCs. Combinando nossos dados com trabalhos já publicados, mostramos que CG30 tem uma eficiência de formação estelar em torno de 3%; que o campo magnético é importante na manutenção da estrutura global do GC e demonstra sinais de torção e compressão; e que a ejeção bipolar de matéria das estrelas do par formam uma ejeção quadripolar, a qual influencia na densidade e temperatura do gás e no grau de polarização dos grãos de poeira associados ao gás do GC.

  20. Functional traits of selected mangrove species in Brazil as biological indicators of different environmental conditions.

    PubMed

    Arrivabene, Hiulana Pereira; Souza, Iara; Có, Walter Luiz Oliveira; Rodella, Roberto Antônio; Wunderlin, Daniel Alberto; Milanez, Camilla Rozindo

    2014-04-01

    Ecological studies on phenotypic plasticity illustrate the relevance of this phenomenon in nature. Conditions of biota reflect environmental changes, highlighting the adaptability of resident species that can be used as bioindicators of such changes. We report the morpho-anatomical plasticity of leaves of Avicennia schaueriana Stapf & Leechm. ex Moldenke, Laguncularia racemosa (L.) C.F.Gaertn. and Rhizophora mangle L., evaluated in three estuaries (Vitória bay, Santa Cruz and Itaúnas River; state of Espírito Santo, Brazil), considering five areas of mangrove ecosystems with diverse environmental issues. Two sampling sites are part of the Ecological Station Lameirão Island in Vitória bay, close to a harbor. A third sampling site in Cariacica (Vitória bay) is inside the Vitória harbor and also is influenced by domestic sewage. The fourth studied area (Santa Cruz) is part of Piraquê Mangrove Ecological Reservation, while the fifth (Itaúnas River) is a small mangrove, with sandy sediment and greater photosynthetically active radiation, also not strongly influenced by anthropic activity. Results pointed out the morpho-anatomical plasticity in studied species, showing that A. schaueriana and L. racemosa might be considered the most appropriate bioindicators to indicate different settings and environmental conditions. Particularly, the dry mass per leaf area (LMA) of A. schaueriana was the main biomarker measured. In our study, LMA of A. schaueriana was positively correlated with salinity (Spearman 0.71), Mn content (0.81) and pH (0.82) but negatively correlated with phosphorus content (-0.63). Thus, the evaluation of modification in LMA of A. schaueriana pointed out changes among five studied sites, suggesting its use to reflect changes in the environment, which could be also useful in the future to evaluate the climate change. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Canine hepatozoonosis in Brazil: description of eight naturally occurring cases.

    PubMed

    Gondim, L F; Kohayagawa, A; Alencar, N X; Biondo, A W; Takahira, R K; Franco, S R

    1998-01-31

    Eight cases of canine hepatozoonosis were diagnosed at the Veterinary Hospital (Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Campus de Botucatu), between October 1993 and April 1994. Clinical signs included anorexia, pale mucous membranes, weight loss, pain, diarrhoea, vomit, gait abnormalities, fever, polyuria and polydipsia. Haematologic findings revealed anaemia in seven cases, leucocytosis with neutrophilia in three cases, lymphopenia in three cases and monocytosis in four cases. Serum biochemistries included alterations in many parameters. The micrometry of Hepatozoon canis gametocytes ranged from 6.8 x 4.0 microns to 7.5 x 4.5 microns. Parasitaemia ranged from less than 0.5% to 2%. In all the cases reported other concurrent diseases were present. Diagnosis of canine hepatozoonosis was made by identifying H. canis gametocytes within leucocytes in stained blood smears.

  2. Monitoring of wind load and response for cable-supported bridges in Hong Kong

    NASA Astrophysics Data System (ADS)

    Wong, Kai-yuen; Chan, Wai-Yee K.; Man, King-Leung

    2001-08-01

    Structural health monitoring for the three cable-supported bridges located in the West of Hong Kong or the Tsing Ma Control Area has been carried out since the opening of these bridges to public traffic. The three cable-supported bridges are referred to as the Tsing Ma (suspension) Bridge, the Kap Shui Mun (cable-stayed) Bridge and the Ting Kau (cable-stayed) Bridge. The structural health monitoring works involved are classified as six monitoring categories, namely, wind load and response, temperature load and response, traffic load and response, geometrical configuration monitoring, strains and stresses/forces monitoring and global dynamic characteristics monitoring. As wind loads and responses had been a major concern in the design and construction stages, this paper therefore outlines the work of wind load and response monitoring on Tsing Ma, Kap Shui Mun and Ting Kau Bridges. The paper starts with a brief description of the sensory systems. The description includes the layout and performance requirements of sensory systems for wind load and responses monitoring. Typical results of wind load and response monitoring in graphical forms are then presented. These graphical forms include the plots of wind rose diagrams, wind incidences vs wind speeds, wind turbulence intensities, wind power spectra, gust wind factors, coefficient of terrain roughness, extreme wind analyses, deck deflections/rotations vs wind speeds, acceleration spectra, acceleration/displacement contours, and stress demand ratios. Finally conclusions on wind load and response monitoring on the three cable-supported bridges are drawn.

  3. Analysis of collaborative communication for linguistic cues of cognitive load.

    PubMed

    Khawaja, M Asif; Chen, Fang; Marcus, Nadine

    2012-08-01

    Analyses of novel linguistic and grammatical features, extracted from transcribed speech of people working in a collaborative environment, were performed for cognitive load measurement Prior studies have attempted to assess users' cognitive load with several measures, but most of them are intrusive and disrupt normal task flow. An effective measurement of people's cognitive load can help improve their performance by deploying appropriate output and support strategies accordingly. The authors studied 33 members of bushfire management teams working collaboratively in computerized incident control rooms and involved in complex bushfire management tasks. The participants' communication was analyzed for some novel linguistic features as potential indices of cognitive load, which included sentence length, use of agreement and disagreement phrases, and use of personal pronouns, including both singular and plural pronoun types. Results showed users' different linguistic and grammatical patterns with various cognitive load levels. Specifically, with high load, people spoke more and used longer sentences, used more words that indicated disagreement with other team members, and exhibited increased use of plural personal pronouns and decreased use of singular pronouns. The article provides encouraging evidence for the use of linguistic and grammatical analysis for measuring users' cognitive load and proposes some novel features as cognitive load indices. The proposed approach may be applied to many data-intense and safety-critical task scenarios, such as emergency management departments, for example, bushfire or traffic incident management centers; air traffic control rooms; and call centers, where speech is used as part of everyday tasks.

  4. Consumption of fast food, sugar-sweetened beverages, artificially-sweetened beverages and allostatic load among young adults.

    PubMed

    van Draanen, Jenna; Prelip, Michael; Upchurch, Dawn M

    2018-06-01

    This study investigates the associations between recent consumption of fast foods, sugar-sweetened beverages, and artificially-sweetened beverages on level of allostatic load, a measure of cumulative biological risk, in young adults in the US. Data from Wave IV of the National Longitudinal Study of Adolescent to Adult Health were analyzed. Negative binomial regression models were used to estimate the associations between consumption of fast foods, sugar-sweetened, and artificially-sweetened beverages and allostatic load. Poisson and logistic regression models were used to estimate the associations between these diet parameters and combined biomarkers of physiological subsystems that comprise our measure of allostatic load. All analyses were weighted and findings are representative of young adults in the US, ages 24-34 in 2008 (n = 11,562). Consumption of fast foods, sugar-sweetened, and artificially-sweetened beverages were associated with higher allostatic load at a bivariate level. Accounting for demographics and medication use, only artificially-sweetened beverages remained significantly associated with allostatic load. When all three dietary components were simultaneously included in a model, both sugar- and artificially-sweetened beverage consumption were associated with higher allostatic load. Differences in allostatic load emerge early in the life course and young adults consuming sugar- or artificially-sweetened beverages have higher allostatic load, net of demographics and medication use. Public health messages to young adults may need to include cautions about both sugar- and artificially-sweetened beverages.

  5. Water Quality Assessment and Determining the Carrying Capacity of Pollution Load Batang Kuranji River

    NASA Astrophysics Data System (ADS)

    Dewata, I.; Adri, Z.

    2018-04-01

    This study aims to determine the water quality and carrying capacity of pollution load Batang Kuranji River in the headwaters, middle, and downstream. This research is descriptive quantitative parameters of pH, BOD, COD, TSS, and DOES Depictions of river water quality refer to RegulationNo.82/2001, while determination of carrying capacity of pollution load river refers to the Kep Men LHNo.10/2003.The result is Kuranji Batang River water quality upstream region included in either category who meet the quality standard first class ofPP82/2001. TSS concentrations at head waters of 21 mg/L, BOD1,6 mg/L, COD7,99mg/L and DO 7,845 mg/L. While the carrying capacity of pollution load river in upstream region included in both categories namely BOD of 4,4 kg/sec, COD 273,60 kg/sec, TSS906,00kg/sec, and DO parameters of 49.20 kg/sec. Middle region (point 2, 3, and 4) water quality Batang Kuranji River has exceeded the quality standard of 82/2001 for class II and class III. Meanwhile, carrying capacity of pollution load river in area included in ugly category. The calculation is done with application Qual2Kw show that carrying capacity of pollution load river of BOD -857.3 kg/sec, COD -777.40 kg/sec, TSS +9511.5 kg/sec, and DO +69.30 kg/sec.

  6. On Ensino da Astronomia no Ensino Médio sob Diferentes Abordagens Metodológicas

    NASA Astrophysics Data System (ADS)

    Voelzke, Marcos Rincon; Albrecht, Evonir

    2011-12-01

    O presente trabalho, sobre a intervenção de metodologias de ensino, foi desenvolvido na Escola Estadual Colônia dos Pescadores, na cidade de Caraguatatuba - SP, em três turmas do terceiro ano do Ensino Médio, perfazendo um total de 119 educandos, entre 16 e 19 anos. Antes de iniciar-se a intervenção, um questionário de vinte perguntas objetivas e dissertativas foi desenvolvido, aplicado pelo professor da classe, que ministrou as aulas correspondentes. Este questionário foi o mesmo em todas as três classes com o objetivo de diagnosticar o conhecimento prévio dos alunos sobre Astronomia. Começando a intervenção nas turmas, o professor envolvido usou três diferentes metodologias de ensino: (A) em forma de seminários, elaborados e apresentados pelos alunos, nos quais o professor fazia apenas as intervenções necessárias, (B) na forma tradicional, com a ajuda de multimídia para o desenvolvimento das aulas e a terceira (C) a tradicional, fazendo uso exclusivo de lousa e giz. No final do trabalho os alunos responderam o mesmo questionário novamente, de modo que os três métodos utilizados puderam ser comparados. Os resultados apresentados após a intervenção foram melhores que os resultados iniciais indicando a ocorrência de uma aprendizagem significativa. Quando os estudantes foram inicialmente questionados sobre quantos planetas existem no nosso sistema solar, a classe A obteve 39% de respostas certas, a classe B 48% e a classe C 46%, mas após o desenvolvimento das atividades, as classes obtiveram respectivamente 94%, 97 % e 90% de aproveitamento. No término do bimestre, foi sugerido aos educandos que elaborassem uma história em quadrinhos, a qual serviu para averiguar se os conceitos inicialmente observados foram alterados e se novos foram agregados. A análise das histórias foi dividida em três partes: Criatividade; Temas abordados; Emprego correto dos conceitos estudados. Ao final quatorze histórias foram confeccionadas. O aprendizado foi tão significativo que os alunos produzira m histórias em quadrinhos, com informações muito ricas. Outro dado muito importante é que, apesar da Astronomia ser um tema amplamente recomendado, não é ensinado nem em escolas de ensino fundamental nem no ensino médio.

  7. Measuring cognitive load during procedural skills training with colonoscopy as an exemplar.

    PubMed

    Sewell, Justin L; Boscardin, Christy K; Young, John Q; Ten Cate, Olle; O'Sullivan, Patricia S

    2016-06-01

    Few studies have investigated cognitive factors affecting learning of procedural skills in medical education. Cognitive load theory, which focuses on working memory, is highly relevant, but methods for measuring cognitive load during procedural training are not well understood. Using colonoscopy as an exemplar, we used cognitive load theory to develop a self-report instrument to measure three types of cognitive load (intrinsic, extraneous and germane load) and to provide evidence for instrument validity. We developed the instrument (the Cognitive Load Inventory for Colonoscopy [CLIC]) using a multi-step process. It included 19 items measuring three types of cognitive load, three global rating items and demographics. We then conducted a cross-sectional survey that was administered electronically to 1061 gastroenterology trainees in the USA. Participants completed the CLIC following a colonoscopy. The two study phases (exploratory and confirmatory) each lasted for 10 weeks during the 2014-2015 academic year. Exploratory factor analysis determined the most parsimonious factor structure; confirmatory factor analysis assessed model fit. Composite measures of intrinsic, extraneous and germane load were compared across years of training and with global rating items. A total of 477 (45.0%) invitees participated (116 in the exploratory study and 361 in the confirmatory study) in 154 (95.1%) training programmes. Demographics were similar to national data from the USA. The most parsimonious factor structure included three factors reflecting the three types of cognitive load. Confirmatory factor analysis verified that a three-factor model was the best fit. Intrinsic, extraneous and germane load items had high internal consistency (Cronbach's alpha 0.90, 0.87 and 0.96, respectively) and correlated as expected with year in training and global assessment of cognitive load. The CLIC measures three types of cognitive load during colonoscopy training. Evidence of validity is provided. Although CLIC items relate to colonoscopy, the development process we detail can be used to adapt the instrument for use in other learning settings in medical education. © 2016 John Wiley & Sons Ltd.

  8. Simulation of upwind maneuvering of a sailing yacht

    NASA Astrophysics Data System (ADS)

    Harris, Daniel Hartrick

    A time domain maneuvering simulation of an IACC class yacht suitable for the analysis of unsteady upwind sailing including tacking is presented. The simulation considers motions in six degrees of freedom. The hydrodynamic and aerodynamic loads are calculated primarily with unsteady potential theory supplemented by empirical viscous models. The hydrodynamic model includes the effects of incident waves. Control of the rudder is provided by a simple rate feedback autopilot which is augmented with open loop additions to mimic human steering. The hydrodynamic models are based on the superposition of force components. These components fall into two groups, those which the yacht will experience in calm water, and those due to incident waves. The calm water loads are further divided into zero Froude number, or "double body" maneuvering loads, hydrostatic loads, gravitational loads, free surface radiation loads, and viscous/residual loads. The maneuvering loads are calculated with an unsteady panel code which treats the instantaneous geometry of the yacht below the undisturbed free surface. The free surface radiation loads are calculated via convolution of impulse response functions derived from seakeeping strip theory. The viscous/residual loads are based upon empirical estimates. The aerodynamic model consists primarily of a database of steady state sail coefficients. These coefficients treat the individual contributions to the total sail force of a number of chordwise strips on both the main and jib. Dynamic effects are modeled by using the instantaneous incident wind velocity and direction as the independent variables for the sail load contribution of each strip. The sail coefficient database was calculated numerically with potential methods and simple empirical viscous corrections. Additional aerodynamic load calculations are made to determine the parasitic contributions of the rig and hull. Validation studies compare the steady sailing hydro and aerodynamic loads, seaway induced motions, added resistance in waves, and tacking performance with trials data and other sources. Reasonable agreement is found in all cases.

  9. Compilation of load spectrum of loader drive axle

    NASA Astrophysics Data System (ADS)

    Wei, Yongxiang; Zhu, Haoyue; Tang, Heng; Yuan, Qunwei

    2018-03-01

    In order to study the preparation method of gear fatigue load spectrum for loaders, the load signal of four typical working conditions of loader is collected. The signal that reflects the law of load change is obtained by preprocessing the original signal. The torque of the drive axle is calculated by using the rain flow counting method. According to the operating time ratio of each working condition, the two dimensional load spectrum based on the real working conditions of the drive axle of loader is established by the cycle extrapolation and synthesis method. The two-dimensional load spectrum is converted into one-dimensional load spectrum by means of the mean of torque equal damage method. Torque amplification includes the maximum load torque of the main reduction gear. Based on the theory of equal damage, the accelerated cycles are calculated. In this way, the load spectrum of the loading condition of the drive axle is prepared to reflect loading condition of the loader. The load spectrum can provide reference for fatigue life test and life prediction of loader drive axle.

  10. Community-driven demand creation for the use of routine viral load testing: a model to scale up routine viral load testing.

    PubMed

    Killingo, Bactrin M; Taro, Trisa B; Mosime, Wame N

    2017-11-01

    HIV treatment outcomes are dependent on the use of viral load measurement. Despite global and national guidelines recommending the use of routine viral load testing, these policies alone have not translated into widespread implementation or sufficiently increased access for people living with HIV (PLHIV). Civil society and communities of PLHIV recognize the need to close this gap and to enable the scale up of routine viral load testing. The International Treatment Preparedness Coalition (ITPC) developed an approach to community-led demand creation for the use of routine viral load testing. Using this Community Demand Creation Model, implementers follow a step-wise process to capacitate and empower communities to address their most pressing needs. This includes utlizing a specific toolkit that includes conducting a baseline assessment, developing a treatment education toolkit, organizing mobilization workshops for knowledge building, provision of small grants to support advocacy work and conducting benchmark evaluations. The Community Demand Creation Model to increase demand for routine viral load testing services by PLHIV has been delivered in diverse contexts including in the sub-Saharan African, Asian, Latin American and the Caribbean regions. Between December 2015 and December 2016, ITPC trained more than 240 PLHIV activists, and disbursed US$90,000 to network partners in support of their national advocacy work. The latter efforts informed a regional, community-driven campaign calling for domestic investment in the expeditious implementation of national viral load testing guidelines. HIV treatment education and community mobilization are critical components of demand creation for access to optimal HIV treatment, especially for the use of routine viral load testing. ITPC's Community Demand Creation Model offers a novel approach to achieving this goal. © 2017 The Authors. Journal of the International AIDS Society published by John Wiley & sons Ltd on behalf of the International AIDS Society.

  11. Is there a causal link between knee loading and knee osteoarthritis progression? A systematic review and meta-analysis of cohort studies and randomised trials

    PubMed Central

    Henriksen, Marius; Creaby, Mark W; Lund, Hans; Juhl, Carsten; Christensen, Robin

    2014-01-01

    Objective We performed a systematic review, meta-analysis and assessed the evidence supporting a causal link between knee joint loading during walking and structural knee osteoarthritis (OA) progression. Design Systematic review, meta-analysis and application of Bradford Hill's considerations on causation. Data sources We searched MEDLINE, Scopus, AMED, CINAHL and SportsDiscus for prospective cohort studies and randomised controlled trials (RCTs) from 1950 through October 2013. Study eligibility criteria We selected cohort studies and RCTs in which estimates of knee joint loading during walking were used to predict structural knee OA progression assessed by X-ray or MRI. Data analyses Meta-analysis was performed to estimate the combined OR for structural disease progression with higher baseline loading. The likelihood of a causal link between knee joint loading and OA progression was assessed from cohort studies using the Bradford Hill guidelines to derive a 0–4 causation score based on four criteria and examined for confirmation in RCTs. Results Of the 1078 potentially eligible articles, 5 prospective cohort studies were included. The studies included a total of 452 patients relating joint loading to disease progression over 12–72 months. There were very serious limitations associated with the methodological quality of the included studies. The combined OR for disease progression was 1.90 (95% CI 0.85 to 4.25; I2=77%) for each one-unit increment in baseline knee loading. The combined causation score was 0, indicating no causal association between knee loading and knee OA progression. No RCTs were found to confirm or refute the findings from the cohort studies. Conclusions There is very limited and low-quality evidence to support for a causal link between knee joint loading during walking and structural progression of knee OA. Trial registration number CRD42012003253 PMID:25031196

  12. Is there a causal link between knee loading and knee osteoarthritis progression? A systematic review and meta-analysis of cohort studies and randomised trials.

    PubMed

    Henriksen, Marius; Creaby, Mark W; Lund, Hans; Juhl, Carsten; Christensen, Robin

    2014-07-15

    We performed a systematic review, meta-analysis and assessed the evidence supporting a causal link between knee joint loading during walking and structural knee osteoarthritis (OA) progression. Systematic review, meta-analysis and application of Bradford Hill's considerations on causation. We searched MEDLINE, Scopus, AMED, CINAHL and SportsDiscus for prospective cohort studies and randomised controlled trials (RCTs) from 1950 through October 2013. We selected cohort studies and RCTs in which estimates of knee joint loading during walking were used to predict structural knee OA progression assessed by X-ray or MRI. Meta-analysis was performed to estimate the combined OR for structural disease progression with higher baseline loading. The likelihood of a causal link between knee joint loading and OA progression was assessed from cohort studies using the Bradford Hill guidelines to derive a 0-4 causation score based on four criteria and examined for confirmation in RCTs. Of the 1078 potentially eligible articles, 5 prospective cohort studies were included. The studies included a total of 452 patients relating joint loading to disease progression over 12-72 months. There were very serious limitations associated with the methodological quality of the included studies. The combined OR for disease progression was 1.90 (95% CI 0.85 to 4.25; I(2)=77%) for each one-unit increment in baseline knee loading. The combined causation score was 0, indicating no causal association between knee loading and knee OA progression. No RCTs were found to confirm or refute the findings from the cohort studies. There is very limited and low-quality evidence to support for a causal link between knee joint loading during walking and structural progression of knee OA. CRD42012003253. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. Modeling and Simulation of a Helicopter Slung Load Stabilization Device

    NASA Technical Reports Server (NTRS)

    Cicolani, Luigi S.; Ehlers, George E.

    2002-01-01

    This paper addresses the problem of simulation and stabilization of the yaw motions of a cargo container slung load. The study configuration is a UH-60 helicopter carrying a 6ft x 6 ft x 8 ft CONEX container. This load is limited to 60 KIAS in operations and flight testing indicates that it starts spinning in hover and that spin rate increases with airspeed. The simulation reproduced the load yaw motions seen in the flight data after augmenting the load model with terms representing unsteady load yaw moment effects acting to reinforce load oscillations, and augmenting the hook model to include yaw resistance at the hook. The use of a vertical fin to stabilize the load is considered. Results indicate that the CONEX airspeed can be extended to 110 kts using a 3x5 ft fin.

  14. Trends in asthma mortality in the 0- to 4-year and 5- to 34-year age groups in Brazil.

    PubMed

    Graudenz, Gustavo Silveira; Carneiro, Dominique Piacenti; Vieira, Rodolfo de Paula

    2017-01-01

    To provide an update on trends in asthma mortality in Brazil for two age groups: 0-4 years and 5-34 years. Data on mortality from asthma, as defined in the International Classification of Diseases, were obtained for the 1980-2014 period from the Mortality Database maintained by the Information Technology Department of the Brazilian Unified Health Care System. To analyze time trends in standardized asthma mortality rates, we conducted an ecological time-series study, using regression models for the 0- to 4-year and 5- to 34-year age groups. There was a linear trend toward a decrease in asthma mortality in both age groups, whereas there was a third-order polynomial fit in the general population. Although asthma mortality showed a consistent, linear decrease in individuals ≤ 34 years of age, the rate of decline was greater in the 0- to 4-year age group. The 5- to 34-year group also showed a linear decline in mortality, and the rate of that decline increased after the year 2004, when treatment with inhaled corticosteroids became more widely available. The linear decrease in asthma mortality found in both age groups contrasts with the nonlinear trend observed in the general population of Brazil. The introduction of inhaled corticosteroid use through public policies to control asthma coincided with a significant decrease in asthma mortality rates in both subsets of individuals over 5 years of age. The causes of this decline in asthma-related mortality in younger age groups continue to constitute a matter of debate. Apresentar uma atualização das tendências da mortalidade da asma no Brasil em duas faixas etárias: 0-4 anos e 5-34 anos. Dados relativos ao período de 1980 a 2014 referentes à mortalidade da asma, conforme se definiu na Classificação Internacional de Doenças, foram extraídos Sistema de Informação sobre Mortalidade do Departamento de Tecnologia da Informação do Sistema Único de Saúde. Para analisar as tendências temporais das taxas padronizadas de mortalidade da asma, realizou-se um estudo ecológico de séries temporais com modelos de regressão para as faixas etárias de 0 a 4 anos e 5 a 34 anos. Houve uma tendência linear de redução da mortalidade da asma em ambas as faixas etárias e uma tendência polinomial de terceira ordem na população geral. Embora a mortalidade da asma tenha apresentado redução linear consistente em indivíduos com idade ≤ 34 anos, a taxa de declínio foi maior na faixa etária de 0 a 4 anos. A faixa etária de 5 a 34 anos também apresentou redução linear da mortalidade, e essa redução tornou-se mais pronunciada após o ano de 2004, quando o tratamento com corticosteroides inalatórios tornou-se mais amplamente disponível. A redução linear da mortalidade da asma em ambas as faixas etárias contrasta com a tendência não linear observada na população geral do Brasil. A introdução do uso de corticosteroides inalatórios por meio de políticas públicas de controle da asma coincidiu com uma diminuição significativa das taxas de mortalidade da asma em ambos os subgrupos de indivíduos com mais de 5 anos de idade. As causas dessa redução da mortalidade da asma em faixas etárias mais jovens ainda são objeto de debate.

  15. Reliability at the lower limits of HIV-1 RNA quantification in clinical samples: a comparison of RT-PCR versus bDNA assays.

    PubMed

    Lubelchek, Ronald J; Max, Blake; Sandusky, Caroline J; Hota, Bala; Barker, David E

    2009-06-23

    To explore whether an assay change was responsible for an increasing proportion of patients with undetectable HIV viral loads at our urban HIV clinic, we selected highly stable patients, examining their viral loads before and after changing assays. We compared the proportion with detectable viremia during RT-PCR vs. bDNA periods. We selected patients with > or =1 viral loads assessed during both RT-PCR and bDNA periods. We included patients with stable CD4 counts, excluding patients with viral loads > or =1,000 copies/ml or any significant changes in therapy. Out of 4500 clinic patients, 419 patients (1588 viral loads) were included. 39% of viral loads were reported as detectable by RT-PCR vs. 5% reported as detectable by bDNA. The mean coefficient of variation was higher before vs. after assay change. We found an odds' ratio of 16.7 for having a viral load >75 copies/ml during the RT-PCR vs. bDNA periods. These data support previous reports, suggesting that bDNA may more reliably discriminate between viral suppression and low level viremia in stable patients on therapy. Low-level viremia, noted more with RT-PCR, may promote unneeded testing, while differences in viral load reliability may impact antiretroviral trial and quality assurance endpoints. Commonly used plasma separator tubes may differentially affect RT-PCR and bDNA results.

  16. Association of education and receiving social transfers with allostatic load in the Swiss population-based CoLaus study.

    PubMed

    Nicod, Edouard; Stringhini, Silvia; Marques-Vidal, Pedro; Paccaud, Fred; Waeber, Gérard; Lamiraud, Karine; Vollenweider, Peter; Bochud, Murielle

    2014-06-01

    Allostatic load reflects cumulative exposure to stressors throughout lifetime and has been associated with several adverse health outcomes. It is hypothesized that people with low socioeconomic status (SES) are exposed to higher chronic stress and have therefore greater levels of allostatic load. To assess the association of receiving social transfers and low education with allostatic load. We included 3589 participants (1812 women) aged over 35years and under retirement age from the population-based CoLaus study (Lausanne, Switzerland, 2003-2006). We computed an allostatic load index aggregating cardiovascular, metabolic, dyslipidemic and inflammatory markers. A novel index additionally including markers of oxidative stress was also examined. Men with low vs. high SES were more likely to have higher levels of allostatic load (odds ratio (OR)=1.93/2.34 for social transfers/education, 95%CI from 1.45 to 4.17). The same patterns were observed among women. Associations persisted after controlling for health behaviors and marital status. Low education and receiving social transfers independently and cumulatively predict high allostatic load and dysregulation of several homeostatic systems in a Swiss population-based study. Participants with low SES are at higher risk of oxidative stress, which may justify its inclusion as a separate component of allostatic load. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Load estimator (LOADEST): a FORTRAN program for estimating constituent loads in streams and rivers

    USGS Publications Warehouse

    Runkel, Robert L.; Crawford, Charles G.; Cohn, Timothy A.

    2004-01-01

    LOAD ESTimator (LOADEST) is a FORTRAN program for estimating constituent loads in streams and rivers. Given a time series of streamflow, additional data variables, and constituent concentration, LOADEST assists the user in developing a regression model for the estimation of constituent load (calibration). Explanatory variables within the regression model include various functions of streamflow, decimal time, and additional user-specified data variables. The formulated regression model then is used to estimate loads over a user-specified time interval (estimation). Mean load estimates, standard errors, and 95 percent confidence intervals are developed on a monthly and(or) seasonal basis. The calibration and estimation procedures within LOADEST are based on three statistical estimation methods. The first two methods, Adjusted Maximum Likelihood Estimation (AMLE) and Maximum Likelihood Estimation (MLE), are appropriate when the calibration model errors (residuals) are normally distributed. Of the two, AMLE is the method of choice when the calibration data set (time series of streamflow, additional data variables, and concentration) contains censored data. The third method, Least Absolute Deviation (LAD), is an alternative to maximum likelihood estimation when the residuals are not normally distributed. LOADEST output includes diagnostic tests and warnings to assist the user in determining the appropriate estimation method and in interpreting the estimated loads. This report describes the development and application of LOADEST. Sections of the report describe estimation theory, input/output specifications, sample applications, and installation instructions.

  18. Pseudo-spectral control of a novel oscillating surge wave energy converter in regular waves for power optimization including load reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tom, Nathan M.; Yu, Yi -Hsiang; Wright, Alan D.

    The aim of this study is to describe a procedure to maximize the power-to-load ratio of a novel wave energy converter (WEC) that combines an oscillating surge wave energy converter with variable structural components. The control of the power-take-off torque will be on a wave-to-wave timescale, whereas the structure will be controlled statically such that the geometry remains the same throughout the wave period. Linear hydrodynamic theory is used to calculate the upper and lower bounds for the time-averaged absorbed power and surge foundation loads while assuming that the WEC motion remains sinusoidal. Previous work using pseudo-spectral techniques to solvemore » the optimal control problem focused solely on maximizing absorbed energy. This work extends the optimal control problem to include a measure of the surge foundation force in the optimization. The objective function includes two competing terms that force the optimizer to maximize power capture while minimizing structural loads. A penalty weight was included with the surge foundation force that allows control of the optimizer performance based on whether emphasis should be placed on power absorption or load shedding. Results from pseudo-spectral optimal control indicate that a unit reduction in time-averaged power can be accompanied by a greater reduction in surge-foundation force.« less

  19. Pseudo-spectral control of a novel oscillating surge wave energy converter in regular waves for power optimization including load reduction

    DOE PAGES

    Tom, Nathan M.; Yu, Yi -Hsiang; Wright, Alan D.; ...

    2017-04-18

    The aim of this study is to describe a procedure to maximize the power-to-load ratio of a novel wave energy converter (WEC) that combines an oscillating surge wave energy converter with variable structural components. The control of the power-take-off torque will be on a wave-to-wave timescale, whereas the structure will be controlled statically such that the geometry remains the same throughout the wave period. Linear hydrodynamic theory is used to calculate the upper and lower bounds for the time-averaged absorbed power and surge foundation loads while assuming that the WEC motion remains sinusoidal. Previous work using pseudo-spectral techniques to solvemore » the optimal control problem focused solely on maximizing absorbed energy. This work extends the optimal control problem to include a measure of the surge foundation force in the optimization. The objective function includes two competing terms that force the optimizer to maximize power capture while minimizing structural loads. A penalty weight was included with the surge foundation force that allows control of the optimizer performance based on whether emphasis should be placed on power absorption or load shedding. Results from pseudo-spectral optimal control indicate that a unit reduction in time-averaged power can be accompanied by a greater reduction in surge-foundation force.« less

  20. Wind/seismic comparisons for upgrading existing structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giller, R.A.

    1989-10-01

    This paper depicts the analysis procedures and methods used to evaluate three existing building structures for extreme wind loads. The three structures involved in this evaluation are located at the US Department of Energy's Hanford Site near Richland, Washington. This site is characterized by open flat grassland with few surrounding obstructions and has extreme winds in lieu of tornados as a design basis accident condition. This group of buildings represents a variety of construction types, including a concrete stack, a concrete load-bearing wall structure, and a rigid steel-frame building. The three structures included in this group have recently been evaluatedmore » for response to the design basis earthquake that included non-linear time history effects. The resulting loads and stresses from the wind analyses were compared to the loads and stresses resulting from seismic analyses. This approach eliminated the need to prepare additional capacity calculations that were already contained in the seismic evaluations. 4 refs., 5 figs., 5 tabs.« less

  1. It's not what you put on, but what you take off: techniques for debriding and off-loading the diabetic foot wound.

    PubMed

    Armstrong, David G; Lavery, Lawrence A; Nixon, Brent P; Boulton, Andrew J M

    2004-08-01

    The basic etiology of neuropathic diabetic foot wounds involves pressure in conjunction with cycles of repetitive stress, leading to failure of skin and soft tissue. The central tenet of any treatment plan addressing neuropathic diabetic foot wounds is the appropriate debridement of nonviable tissue coupled with adequate pressure relief (off-loading). Although numerous advances have been made in the treatment of diabetic foot wounds, including bioengineered tissues, autologous and exogenous cytokine delivery systems, and potentially effective topical antimicrobial modalities, none will succeed without addressing effective debridement and off-loading. Specific debridement and off-loading techniques are discussed, along with available supporting evidence. This includes the use of the "instant" total contact cast, among other modalities.

  2. NO.sub.x catalyst and method of suppressing sulfate formation in an exhaust purification system

    DOEpatents

    Balmer-Millar, Mari Lou [Chillicothe, IL; Park, Paul W [Peoria, IL; Panov, Alexander G [Peoria, IL

    2007-06-26

    The activity and durability of a zeolite lean-burn NOx catalyst can be increased by loading metal cations on the outer surface of the zeolite. However, the metal loadings can also oxidize sulfur dioxide to cause sulfate formation in the exhaust. The present invention is a method of suppressing sulfate formation in an exhaust purification system including a NO.sub.x catalyst. The NO.sub.x catalyst includes a zeolite loaded with at least one metal. The metal is selected from among an alkali metal, an alkaline earth metal, a lanthanide metal, a noble metal, and a transition metal. In order to suppress sulfate formation, at least a portion of the loaded metal is complexed with at least one of sulfate, phosphate, and carbonate.

  3. NO.sub.x catalyst and method of suppressing sulfate formation in an exhaust purification system

    DOEpatents

    Balmer-Millar, Mari Lou; Park, Paul W.; Panov, Alexander G.

    2006-08-22

    The activity and durability of a zeolite lean-bum NOx catalyst can be increased by loading metal cations on the outer surface of the zeolite. However, the metal loadings can also oxidize sulfur dioxide to cause sulfate formation in the exhaust. The present invention is a method of suppressing sulfate formation in an exhaust purification system including a NO.sub.x catalyst. The NO.sub.x catalyst includes a zeolite loaded with at least one metal. The metal is selected from among an alkali metal, an alkaline earth metal, a lanthanide metal, a noble metal, and a transition metal. In order to suppress sulfate formation, at least a portion of the loaded metal is complexed with at least one of sulfate, phosphate, and carbonate.

  4. A biomechanical model for actively controlled snow ski bindings.

    PubMed

    Hull, M L; Ramming, J E

    1980-11-01

    Active control of snow ski bindings is a new design concept which potentially offers improved protection from lower extremity injury. Implementation of this concept entails measuring physical variables and calculating loading and/or deformation in injury prone musculoskeletal components. The subject of this paper is definition of a biomechanical model for calculating tibia torsion based on measurements of torsion loading between the boot and ski. Previous control schemes have used leg displacement only to indicate tibia torsion. The contributions of both inertial and velocity-dependent torques to tibia loading are explored and it is shown that both these moments must be included in addition to displacement-dependent moments. A new analog controller design which includes inertia, damping, and stiffness terms in the tibia load calculation is also presented.

  5. Systems and methods for providing power to a load based upon a control strategy

    DOEpatents

    Perisic, Milun; Kajouke, Lateef A; Ransom, Ray M

    2013-12-24

    Systems and methods are provided for an electrical system. The electrical system includes a load, an interface configured to receive a voltage from a voltage source, and a controller configured to receive the voltage from the voltage source through the interface and to provide a voltage and current to the load. Wherein, when the controller is in a constant voltage mode, the controller provides a constant voltage to the load, when the controller is in a constant current mode, the controller provides a constant current to the load, and when the controller is in a constant power mode, the controller provides a constant power to the load.

  6. Surface water subduction during a downwelling event in a semienclosed bay

    NASA Astrophysics Data System (ADS)

    Barton, E. D.; Torres, R.; Figueiras, F. G.; Gilcoto, M.; Largier, J.

    2016-09-01

    The Ría de Vigo is a bay strongly influenced by upwelling-downwelling cycles along the adjacent coast of NW Iberia. Moored and ship-board observations during September 2006 showed that subduction, initially associated with an estuarine circulation, strengthened when a strong downwelling circulation, resulting from northward wind over the coastal ocean, was generated in the outer Ría causing ambient waters to be advected outward in the lower layer. Incoming surface waters confined the estuarine circulation to the shallow interior and displaced isopleths downward through the water column at ˜10 m d-1. As the estuarine circulation retreated inward, strong flow convergence developed between middle and inner ria in the layer above 15 m, while divergence developed beneath. The convergence increased through the period of downwelling-favorable wind at a rate consistent with the observed isopleth displacement velocities. The coefficient of turbulent diffusion Kt, from a microstructure profiler, indicated that mixing was strong in the estuarine circulation and subsequently in the downwelling zone, where localized instabilities and temperature-salinity inversions were observed. During the downwelling, concentrations of phytoplankton, including potentially harmful species, increased, especially in the middle and inner ria, as a result of inward advection, subduction, and the ability of the dinoflagellates to maintain their position in the water column by swimming. In the course of the 5 day event, the water mass of all but the innermost Ría was flushed completely and replaced by waters originating in the coastally trapped poleward flow along the Atlantic coastline.

  7. Prevalence of metabolic syndrome and related factors in bank employees according to different defining criteria, Vitória/ES, Brazil.

    PubMed

    Salaroli, Luciane Bresciani; Saliba, Renata Aubin Dias; Zandonade, Eliana; Molina, Maria del Carmen Bisi; Bissoli, Nazaré Souza

    2013-01-01

    To determine the prevalence of metabolic syndrome and related factors in bank employees in the city of Vitória/ES, Brazil. This was a cross-sectional study that included 521 working men and women >20 years of age. Sociodemographic, lifestyle, anthropometric, biochemical, and hemodynamic characteristics were collected. Metabolic syndrome was diagnosed using the criteria of the National Cholesterol Education Program-ATPIII and the International Diabetes Federation. A logistic regression model was used to calculate the crude and adjusted OR of the variables, and the statistical level of significance was set at 5.0%. We identified 86 (17.2%) and 113 (22.6%) subjects with metabolic syndrome according to the criteria of the National Cholesterol Education Program-ATPIII and the International Diabetes Federation, respectively. The risk of developing metabolic syndrome was higher in individuals with a high school education (OR 2.6 [CI(95%), 1.1-6.1]). In overweight and obese subjects, the risks were also higher (OR 12.6 [CI(95%), 4.8-33.2, p = 0.000] and OR 43.7% [CI(95%), 16.1-118.9, p = 0.000], respectively). A large number of bank employees have metabolic syndrome, which can be associated with an increased risk of developing cardiovascular disease. Individuals who had college degrees had a higher prevalence of metabolic syndrome; this finding can be explained by the high rates of overweight and obesity found in subjects with college and graduate school educations.

  8. Use of an innovative video feedback technique to enhance communication skills training.

    PubMed

    Roter, Debra L; Larson, Susan; Shinitzky, Harold; Chernoff, Robin; Serwint, Janet R; Adamo, Graceanne; Wissow, Larry

    2004-02-01

    Despite growing interest in medical communication by certification bodies, significant methodological and logistic challenges are evident in experiential methods of instruction. There were three study objectives: 1) to explore the acceptability of an innovative video feedback programme to residents and faculty; 2) to evaluate a brief teaching intervention comprising the video feedback innovation when linked to a one-hour didactic and role-play teaching session on paediatric residents' communication with a simulated patient; and 3) to explore the impact of resident gender on communication change. Pre/post comparison of residents' performance in videotaped interviews with simulated patients before and after the teaching intervention. Individually tailored feedback on targeted communication skills was facilitated by embedding the Roter Interaction Analysis System (RIAS) within a software platform that presents a fully coded interview with instant search and review features. 28 first year residents in a large, urban, paediatric residency programme. Communication changes following the teaching intervention were demonstrated through significant improvements in residents' performance with simulated patients pre and post teaching and feedback. Using paired t-tests, differences include: reduced verbal dominance; increased use of open-ended questions; increased use of empathy; and increased partnership building and problem solving for therapeutic regimen adherence. Female residents demonstrated greater communication change than males. The RIAS embedded CD-ROM provides a flexible structure for individually tailoring feedback of targeted communication skills that is effective in facilitating communication change as part of a very brief teaching intervention.

  9. A complete dosimetry experimental program in support to the core characterization and to the power calibration of the CABRI reactor. A complete dosimetry experimental program in support of the core characterization and of the power calibration of the CABRI reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodiac, F.; Hudelot, JP.; Lecerf, J.

    CABRI is an experimental pulse reactor operated by CEA at the Cadarache research center. Since 1978 the experimental programs have aimed at studying the fuel behavior under Reactivity Initiated Accident (RIA) conditions. Since 2003, it has been refurbished in order to be able to provide RIA and LOCA (Loss Of Coolant Accident) experiments in prototypical PWR conditions (155 bar, 300 deg. C). This project is part of a broader scope including an overall facility refurbishment and a safety review. The global modification is conducted by the CEA project team. It is funded by IRSN, which is conducting the CIP experimentalmore » program, in the framework of the OECD/NEA project CIP. It is financed in the framework of an international collaboration. During the reactor restart, commissioning tests are realized for all equipment, systems and circuits of the reactor. In particular neutronics and power commissioning tests will be performed respectively in 2015 and 2016. This paper focuses on the design of a complete and original dosimetry program that was built in support to the CABRI core characterization and to the power calibration. Each one of the above experimental goals will be fully described, as well as the target uncertainties and the forecasted experimental techniques and data treatment. (authors)« less

  10. Methods and apparatus for reduction of asymmetric rotor loads in wind turbines

    DOEpatents

    Moroz, Emilian Mieczyslaw; Pierce, Kirk Gee

    2006-10-10

    A method for reducing load and providing yaw alignment in a wind turbine includes measuring displacements or moments resulting from asymmetric loads on the wind turbine. These measured displacements or moments are used to determine a pitch for each rotor blade to reduce or counter asymmetric rotor loading and a favorable yaw orientation to reduce pitch activity. Yaw alignment of the wind turbine is adjusted in accordance with the favorable yaw orientation and the pitch of each rotor blade is adjusted in accordance with the determined pitch to reduce or counter asymmetric rotor loading.

  11. Load assumptions for the landing impact of seaplanes

    NASA Technical Reports Server (NTRS)

    Taub, Josef

    1931-01-01

    The formula for the impact of floats must include the enlargement factor itself as well as the type of enlargement. The latter is preferably characterized by the change in surface loading. It is shown that the enlargement of a small seaplane generally results in a changed float (or boat) loading as well as wing loading. The conditions of starting stipulate the retention of the float loading when changing from single-float (boat) to twin-float arrangement. This contingency is followed by an increased impact factor in the twin-float type against the otherwise equivalent single-float type.

  12. Load regulating expansion fixture

    DOEpatents

    Wagner, Lawrence M.; Strum, Michael J.

    1998-01-01

    A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located therebetween. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components.

  13. Foil system fatigue load environments for commercial hydrofoil operation

    NASA Technical Reports Server (NTRS)

    Graves, D. L.

    1979-01-01

    The hydrofoil fatigue loads environment in the open sea is examined. The random nature of wave orbital velocities, periods and heights plus boat heading, speed and control system design are considered in the assessment of structural fatigue requirements. Major nonlinear load events such as hull slamming and foil unwetting are included in the fatigue environment. Full scale rough water load tests, field experience plus analytical loads work on the model 929 Jetfoil commercial hydrofoil are discussed. The problem of developing an overall sea environment for design is defined. State of the art analytical approaches are examined.

  14. Determining a Prony Series for a Viscoelastic Material From Time Varying Strain Data

    NASA Technical Reports Server (NTRS)

    Tzikang, Chen

    2000-01-01

    In this study a method of determining the coefficients in a Prony series representation of a viscoelastic modulus from rate dependent data is presented. Load versus time test data for a sequence of different rate loading segments is least-squares fitted to a Prony series hereditary integral model of the material tested. A nonlinear least squares regression algorithm is employed. The measured data includes ramp loading, relaxation, and unloading stress-strain data. The resulting Prony series which captures strain rate loading and unloading effects, produces an excellent fit to the complex loading sequence.

  15. X-33 LH2 Tank Failure Investigation Findings

    NASA Technical Reports Server (NTRS)

    Niedermeyer, Mindy; Clinton, R. G., Jr. (Technical Monitor)

    2000-01-01

    This presentation focuses on the tank history, test objectives, failure description, investigation and conclusions. The test objectives include verify structural integrity at 105% expected flight load limit varying the following parameters: cryogenic temperature; internal pressure; and mechanical loading. The Failure description includes structural component of the aft body, quad-lobe design, and sandwich - honeycomb graphite epoxy construction.

  16. Alternative Fuels Data Center: Raleigh, North Carolina, Paves the Way for

    Science.gov Websites

    of North Carolina at Chapel Hill. It's no surprise that Raleigh is a leader in PEV deployment as well charging on the electrical grid; implementing a three-year load research project that included installing requirements, including load calculations and a detailed plan review. For more information, visit the city's

  17. Factors affecting disability and physical function in degenerative lumbar spondylolisthesis of L4-5: evaluation with axially loaded MRI.

    PubMed

    Huang, Kuo-Yuan; Lin, Ruey-Mo; Lee, Yung-Ling; Li, Jenq-Daw

    2009-12-01

    Few studies have investigated the factors related to the disability and physical function in degenerative lumbar spondylolisthesis using axially loaded magnetic resonance imaging (MRI). Therefore, we aimed to investigate the effect of axial loading on the morphology of the spine and the spinal canal in patients with degenerative spondylolisthesis of L4-5 and to correlate morphologic changes to their disability and physical functions. From March 2003 to January 2004, 32 consecutive cases (26 females, 6 males) with degenerative L4-5 spondylolisthesis, grade 1-2, intermittent claudication, and low back pain without sciatica were included in this study. All patients underwent unloaded and axially loaded MRI of the lumbo-sacral spine in supine position to elucidate the morphological findings and to measure the parameters of MRI, including disc height (DH), sagittal translation (ST), segmental angulation (SA), dural sac cross-sectional area (DCSA) at L4-5, and lumbar lordotic angles (LLA) at L1-5 between the unloaded and axially loaded condition. Each patient's disability was evaluated by the Oswestry Disability Index (ODI) questionnaire, and physical functioning (PF) was evaluated by the Physical Function scale proposed by Stucki et al. (Spine 21:796-803, 1996). Three patients were excluded due to the presence of neurologic symptoms found with the axially loaded MRI. Finally, a total of 29 (5 males, 24 females) consecutive patients were included in this study. Comparisons and correlations were done to determine which parameters were critical to the patient's disability and PF. The morphologies of the lumbar spine changed after axially loaded MRI. In six of our patients, we observed adjacent segment degeneration (4 L3-L4 and 2 L5-S1) coexisting with degenerative spondylolisthesis of L4-L5 under axially loaded MRI. The mean values of the SA under pre-load and post-load were 7.14 degrees and 5.90 degrees at L4-L5 (listhetic level), respectively. The mean values of the LLA under pre-load and post-load were 37.03 degrees and 39.28 degrees , respectively. There were significant correlations only between the ODI, PF, and the difference of SA, and between PF and the post-loaded LLA. The changes in SA (L4-L5) during axial loading were well correlated to the ODI and PF scores. In addition, the LLA (L1-L5) under axial loading was well correlated to the PF of patients with degenerative L4-L5 spondylolisthesis. We suggest that the angular instability of the intervertebral disc may play a more important role than neurological compression in the pathogenesis of disability in degenerative lumbar spondylolisthesis.

  18. NERC Policy 10: Measurement of two generation and load balancing IOS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spicer, P.J.; Galow, G.G.

    1999-11-01

    Policy 10 will describe specific standards and metrics for most of the reliability functions described in the Interconnected Operations Services Working Group (IOS WG) report. The purpose of this paper is to discuss, in detail, the proposed metrics for two generation and load balancing IOSs: Regulation; Load Following. For purposes of this paper, metrics include both measurement and performance evaluation. The measurement methods discussed are included in the current draft of the proposed Policy 10. The performance evaluation method discussed is offered by the authors for consideration by the IOS ITF (Implementation Task Force) for inclusion into Policy 10.

  19. Chapter 18: Variable Frequency Drive Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romberger, Jeff

    An adjustable-speed drive (ASD) includes all devices that vary the speed of a rotating load, including those that vary the motor speed and linkage devices that allow constant motor speed while varying the load speed. The Variable Frequency Drive Evaluation Protocol presented here addresses evaluation issues for variable-frequency drives (VFDs) installed on commercial and industrial motor-driven centrifugal fans and pumps for which torque varies with speed. Constant torque load applications, such as those for positive displacement pumps, are not covered by this protocol.

  20. Stress analysis and buckling of J-stiffened graphite-epoxy panel

    NASA Technical Reports Server (NTRS)

    Davis, R. C.

    1980-01-01

    A graphite epoxy shear panel with bonded on J stiffeners was investigated. The panel, loaded to buckling in a picture frame shear test is described. Two finite element models, each of which included the doubler material bonded to the panel skin under the stiffeners and at the panel edges, were used to make a stress analysis of the panel. The shear load distributions in the panel from two commonly used boundary conditions, applied shear load and applied displacement, were compared with the results from one of the finite element models that included the picture frame test fixture.

  1. Solar-Energy System for a Commercial Building--Topeka, Kansas

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Report describes a solar-energy system for space heating, cooling and domestic hot water at a 5,600 square-foot (520-square-meter) Topeka, Kansas, commercial building. System is expected to provide 74% of annual cooling load, 47% of heating load, and 95% of domestic hot-water load. System was included in building design to maximize energy conservation.

  2. Cognitive Load Theory and the Role of Learner Experience: An Abbreviated Review for Educational Practitioners

    ERIC Educational Resources Information Center

    Artino, Anthony R., Jr.

    2008-01-01

    The purpose of this review is to provide educational practitioners with a brief overview of cognitive load theory (CLT) and its major implications for learning. To achieve this objective, the article includes a short description of human cognitive architecture as conceived by cognitive load theorists. Following this overview, the article provides…

  3. A program for calculating load coefficient matrices utilizing the force summation method, L218 (LOADS). Volume 1: Engineering and usage

    NASA Technical Reports Server (NTRS)

    Miller, R. D.; Anderson, L. R.

    1979-01-01

    The LOADS program L218, a digital computer program that calculates dynamic load coefficient matrices utilizing the force summation method, is described. The load equations are derived for a flight vehicle in straight and level flight and excited by gusts and/or control motions. In addition, sensor equations are calculated for use with an active control system. The load coefficient matrices are calculated for the following types of loads: translational and rotational accelerations, velocities, and displacements; panel aerodynamic forces; net panel forces; shears and moments. Program usage and a brief description of the analysis used are presented. A description of the design and structure of the program to aid those who will maintain and/or modify the program in the future is included.

  4. Relativistic impulse approximation analysis of unstable calcium isotopes: {sup 60-74}Ca

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaki, K.

    2009-06-15

    Recent relativistic mean-field calculations have provided nuclear distributions of Ca isotopes whose mass numbers are 60 through 74. We calculate observables of proton elastic scattering from these unstable isotopes and discuss relations between observables and nuclear distributions of such unstable nuclei. The calculations are based on relativistic impulse approximation (RIA) at incident proton energies from 100 through 500 MeV where predictions of RIA have been shown to provide good agreement with experimental data. To validate the use of optimal factorization and first-order calculations at these energies, contributions from the Fermi motion of the target nuclei and multiple scattering are estimatedmore » and compared with results calculated without these effects.« less

  5. Regulatory impact analysis: benefits and costs of proposed surface water treatment rule and total coliform rule

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1987-09-01

    This report contains an analysis of the costs and benefits of controlling microbial contaminants in drinking water through the promulgation of two regulations: (1) the Surface Water Treatment Rule (SWTR); and (2) the Total Coliform Rule. This regulatory impact analysis (RIA) was prepared in accordance with Executive Order 12291, which requires that the costs and benefits of all major rules be examined and compared. The major topical areas covered in the RIA are as follows: problem definition; market imperfections, the need for federal regulation, and consideration of regulatory alternatives; assessment of total costs; assessment of benefits; regulatory flexibility act andmore » Paperwork Reduction Act analyses; and a summary of costs and benefits.« less

  6. Modeling and Depletion Simulations for a High Flux Isotope Reactor Cycle with a Representative Experiment Loading

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chandler, David; Betzler, Ben; Hirtz, Gregory John

    2016-09-01

    The purpose of this report is to document a high-fidelity VESTA/MCNP High Flux Isotope Reactor (HFIR) core model that features a new, representative experiment loading. This model, which represents the current, high-enriched uranium fuel core, will serve as a reference for low-enriched uranium conversion studies, safety-basis calculations, and other research activities. A new experiment loading model was developed to better represent current, typical experiment loadings, in comparison to the experiment loading included in the model for Cycle 400 (operated in 2004). The new experiment loading model for the flux trap target region includes full length 252Cf production targets, 75Se productionmore » capsules, 63Ni production capsules, a 188W production capsule, and various materials irradiation targets. Fully loaded 238Pu production targets are modeled in eleven vertical experiment facilities located in the beryllium reflector. Other changes compared to the Cycle 400 model are the high-fidelity modeling of the fuel element side plates and the material composition of the control elements. Results obtained from the depletion simulations with the new model are presented, with a focus on time-dependent isotopic composition of irradiated fuel and single cycle isotope production metrics.« less

  7. Deformed Shape Calculation of a Full-Scale Wing Using Fiber Optic Strain Data from a Ground Loads Test

    NASA Technical Reports Server (NTRS)

    Jutte, Christine V.; Ko, William L.; Stephens, Craig A.; Bakalyar, John A.; Richards, W. Lance

    2011-01-01

    A ground loads test of a full-scale wing (175-ft span) was conducted using a fiber optic strain-sensing system to obtain distributed surface strain data. These data were input into previously developed deformed shape equations to calculate the wing s bending and twist deformation. A photogrammetry system measured actual shape deformation. The wing deflections reached 100 percent of the positive design limit load (equivalent to 3 g) and 97 percent of the negative design limit load (equivalent to -1 g). The calculated wing bending results were in excellent agreement with the actual bending; tip deflections were within +/- 2.7 in. (out of 155-in. max deflection) for 91 percent of the load steps. Experimental testing revealed valuable opportunities for improving the deformed shape equations robustness to real world (not perfect) strain data, which previous analytical testing did not detect. These improvements, which include filtering methods developed in this work, minimize errors due to numerical anomalies discovered in the remaining 9 percent of the load steps. As a result, all load steps attained +/- 2.7 in. accuracy. Wing twist results were very sensitive to errors in bending and require further development. A sensitivity analysis and recommendations for fiber implementation practices, along with, effective filtering methods are included

  8. Assessment of spatiotemporal variations in the fluvial wash-load component in the 21st century with regard to GCM climate change scenarios.

    PubMed

    Mouri, Goro

    2015-11-15

    For stream water, in which a relationship exists between wash-load concentration and discharge, an estimate of fine-sediment delivery may be obtained from a traditional fluvial wash-load rating curve. Here, we demonstrate that the remaining wash-load material load can be estimated from a traditional empirical principle on a nationwide scale. The traditional technique was applied to stream water for the whole of Japan. Four typical GCMs were selected from the Coupled Model Intercomparison Project Phase 5 (CMIP5) ensemble to provide the driving fields for the following regional climate models to assess the wash-load component based on rating curves: the Model for Interdisciplinary Research on Climate (MIROC), the Meteorological Research Institute Atmospheric General Circulation Model (MRI-GCM), the Hadley Centre Global Environment Model (HadGEM) and the Geophysical Fluid Dynamics Laboratory (GFDL) climate model. The simulations consisted of an ensemble, including multiple physics configurations and different Representative Concentration Pathways (RCP2.6, RCP4.5 and RCP8.5), which was used to produce monthly datasets for the whole country of Japan. The impacts of future climate changes on fluvial wash load in Japanese stream water were based on the balance of changes in hydrological factors. The annual and seasonal variations of the fluvial wash load were assessed from the result of the ensemble analysis in consideration of the Greenhouse Gas (GHG) emission scenarios. The determined results for the amount of wash load increase range from approximately 20 to 110% in the 2040s, especially along part of the Pacific Ocean and the Sea of Japan regions. In the 2090s, the amount of wash load is projected to increase by more than 50% over the whole of Japan. The assessment indicates that seasonal variation is particularly important because the rainy and typhoon seasons, which include extreme events, are the dominant seasons. Because fluvial wash-load-component turbidity appears to vary exponentially, this phenomenon has an impact on the management of social capital, such as drinking water services. Prediction of the impacts of future climate change on fluvial wash-load sediment is crucial for effective environmental planning and the management of social capital to adapt to the next century. We demonstrate that simulations comprise an ensemble of factors, including multiple physical configurations, associated with the wash-load component for the whole of Japan. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Theory and procedure for determining loads and motions in chine-immersed hydrodynamic impacts of prismatic bodies

    NASA Technical Reports Server (NTRS)

    Schnitzer, Emanuel

    1953-01-01

    A theoretical method is derived for the determination of the motions and loads during chine-immersed water landings of prismatic bodies. This method makes use of a variation of two-dimensional deflected water mass over the complete range of immersion, modified by a correction for three-dimensional flow. Equations are simplified through omission of the term proportional to the acceleration of the deflected mass for use in calculation of loads on hulls having moderate and heavy beam loading. The effects of water rise at the keel are included in these equations. In order to make a direct comparison of theory with experiment, a modification of the equations was made to include the effect of finite test-carriage mass. A simple method of computation which can be applied without reading the body of this report is presented as an appendix along with the required theoretical plots for determination of loads and motions in chine-immersed landings.

  10. POSTOP: Postbuckled open-stiffener optimum panels-theory and capability

    NASA Technical Reports Server (NTRS)

    Dickson, J. N.; Biggers, S. B.

    1984-01-01

    The computer program POSTOP was developed to serve as an aid in the analysis and sizing of stiffened composite panels that are loaded in the postbuckling regime. A comprehensive set of analysis routines was coupled to a widely used optimization program to produce this sizing code. POSTOP is intended for the preliminary design of metal or composite panels with open-section stiffeners, subjected to multiple combined biaxial compression (or tension), shear and normal pressure load cases. Longitudinal compression, however, is assumed to be the dominant loading. Temperature, initial bow eccentricity and load eccentricity effects are included. The panel geometry is assumed to be repetitive over several bays in the longitudinal (stiffener) direction as well as in the transverse direction. Analytical routines are included to compute panel stiffnesses, strains, local and panel buckling loads, and skin/stiffener interface stresses. The resulting program is applicable to stiffened panels as commonly used in fuselage, wing, or empennage structures. The analysis procedures and rationale for the assumptions used therein are described in detail.

  11. Composition and temporal stability of turf sediments on inner-shelf coral reefs.

    PubMed

    Gordon, Sophie E; Goatley, Christopher H R; Bellwood, David R

    2016-10-15

    Elevated sediment loads within the epilithic algal matrix (EAM) of coral reefs can increase coral mortality and inhibit herbivory. Yet the composition, distribution and temporal variability of EAM sediment loads are poorly known, especially on inshore reefs. This study quantified EAM sediment loads (including organic particulates) and algal length across the reef profile of two bays at Orpheus Island (inner-shelf Great Barrier Reef) over a six month period. We examined the total sediment mass, organic load, carbonate and silicate content, and the particle sizes of EAM sediments. Throughout the study period, all EAM sediment variables exhibited marked variation among reef zones. However, EAM sediment loads and algal length were consistent between bays and over time, despite major seasonal variation in climate including a severe tropical cyclone. This study provides a comprehensive description of EAM sediments on inshore reefs and highlights the exceptional temporal stability of EAM sediments on coral reefs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Distraction and mind-wandering under load.

    PubMed

    Forster, Sophie

    2013-01-01

    Attention research over the last several decades has provided rich insights into the determinants of distraction, including distractor characteristics, task features, and individual differences. Load Theory represented a particularly important breakthrough, highlighting the critical role of the level and nature of task-load in determining both the efficiency of distractor rejection and the stage of processing at which this occurs. However, until recently studies of distraction were restricted to those measuring rather specific forms of distraction by external stimuli which I argue that, although intended to be irrelevant, were in fact task-relevant. In daily life, attention may be distracted by a wide range of stimuli, which may often be entirely unrelated to any task being performed, and may include not only external stimuli but also internally generated stimuli such as task-unrelated thoughts. This review outlines recent research examining these more general, entirely task-irrelevant, forms of distraction within the framework of Load Theory. I discuss the relation between different forms of distraction, and the universality of load effects across different distractor types and individuals.

  13. Strain Gage Loads Calibration Testing of the Active Aeroelastic Wing F/A-18 Aircraft

    NASA Technical Reports Server (NTRS)

    Lokos, William A.; Olney, Candida D.; Chen, Tony; Crawford, Natalie D.; Stauf, Rick; Reichenbach, Eric Y.; Bessette, Denis (Technical Monitor)

    2002-01-01

    This report describes strain-gage calibration loading through the application of known loads of the Active Aeroelastic Wing F/A-18 airplane. The primary goal of this test is to produce a database suitable for deriving load equations for left and right wing root and fold shear; bending moment; torque; and all eight wing control-surface hinge moments. A secondary goal is to produce a database of wing deflections measured by string potentiometers and the onboard flight deflection measurement system. Another goal is to produce strain-gage data through both the laboratory data acquisition system and the onboard aircraft data system as a check of the aircraft system. Thirty-two hydraulic jacks have applied loads through whiffletrees to 104 tension-compression load pads bonded to the lower wing surfaces. The load pads covered approximately 60 percent of the lower wing surface. A series of 72 load cases has been performed, including single-point, double-point, and distributed load cases. Applied loads have reached 70 percent of the flight limit load. Maximum wingtip deflection has reached nearly 16 in.

  14. 14 CFR 23.907 - Propeller vibration and fatigue.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... stresses or loads, including any stress peaks and resonant conditions, throughout the operational envelope of the airplane by either: (1) Measurement of stresses or loads through direct testing or analysis...

  15. 14 CFR 23.907 - Propeller vibration and fatigue.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... stresses or loads, including any stress peaks and resonant conditions, throughout the operational envelope of the airplane by either: (1) Measurement of stresses or loads through direct testing or analysis...

  16. 14 CFR 23.907 - Propeller vibration and fatigue.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... stresses or loads, including any stress peaks and resonant conditions, throughout the operational envelope of the airplane by either: (1) Measurement of stresses or loads through direct testing or analysis...

  17. Fastener Design Manual

    NASA Technical Reports Server (NTRS)

    Barrett, Richard T.

    1990-01-01

    This manual was written for design engineers to enable them to choose appropriate fasteners for their designs. Subject matter includes fastener material selection, platings, lubricants, corrosion, locking methods, washers, inserts, thread types and classes, fatigue loading, and fastener torque. A section on design criteria covers the derivation of torque formulas, loads on a fastener group, combining simultaneous shear and tension loads, pullout load for tapped holes, grip length, head styles, and fastener strengths. The second half of this manual presents general guidelines and selection criteria for rivets and lockbolts.

  18. Charts for Determining Preliminary Values of Span-load, Shear, Bending-moment, and Accumulated-torque Distributions of Swept Wings of Various Taper Ratios

    NASA Technical Reports Server (NTRS)

    Wollner, Bertram C

    1948-01-01

    Contains charts for use in determining preliminary values of the spanwise-load, shear, bending-moment, and accumulated-torque distributions of swept wings. The charts are based on strip theory and include four aerodynamic-load distributions, two section-moment distributions, and two inertia-load distributions. The taper ratios considered cover the range from 1.0 to 0 and the results are applicable to any angle of sweep.

  19. Noncontact minimally invasive technique for the assessment of mechanical properties of single cardiac myocyte via magnetic field loading

    NASA Astrophysics Data System (ADS)

    Yin, Shizhuo; Zhang, Xueqian; Cheung, Joseph; Wu, Juntao; Zhan, Chun; Xue, Jinchao

    2004-07-01

    In this paper, a unique non-contact, minimum invasive technique for the assessment of mechanical properties of single cardiac myocyte is presented. The assessment process includes following major steps: (1) attach a micro magnetic bead to the cell to be measured, (2) measure the contractile performance of the cell under the different magnetic field loading, (3) calculate mechanical loading force, and (4) derive the contractile force from the measured contraction data under different magnetic field loading.

  20. Viscoelasticity, postseismic slip, fault interactions, and the recurrence of large earthquakes

    USGS Publications Warehouse

    Michael, A.J.

    2005-01-01

    The Brownian Passage Time (BPT) model for earthquake recurrence is modified to include transient deformation due to either viscoelasticity or deep post seismic slip. Both of these processes act to increase the rate of loading on the seismogenic fault for some time after a large event. To approximate these effects, a decaying exponential term is added to the BPT model's uniform loading term. The resulting interevent time distributions remain approximately lognormal, but the balance between the level of noise (e.g., unknown fault interactions) and the coefficient of variability of the interevent time distribution changes depending on the shape of the loading function. For a given level of noise in the loading process, transient deformation has the effect of increasing the coefficient of variability of earthquake interevent times. Conversely, the level of noise needed to achieve a given level of variability is reduced when transient deformation is included. Using less noise would then increase the effect of known fault interactions modeled as stress or strain steps because they would be larger with respect to the noise. If we only seek to estimate the shape of the interevent time distribution from observed earthquake occurrences, then the use of a transient deformation model will not dramatically change the results of a probability study because a similar shaped distribution can be achieved with either uniform or transient loading functions. However, if the goal is to estimate earthquake probabilities based on our increasing understanding of the seismogenic process, including earthquake interactions, then including transient deformation is important to obtain accurate results. For example, a loading curve based on the 1906 earthquake, paleoseismic observations of prior events, and observations of recent deformation in the San Francisco Bay region produces a 40% greater variability in earthquake recurrence than a uniform loading model with the same noise level.

  1. Extreme load alleviation using industrial implementation of active trailing edge flaps in a full design load basis

    NASA Astrophysics Data System (ADS)

    Barlas, Thanasis; Pettas, Vasilis; Gertz, Drew; Madsen, Helge A.

    2016-09-01

    The application of active trailing edge flaps in an industrial oriented implementation is evaluated in terms of capability of alleviating design extreme loads. A flap system with basic control functionality is implemented and tested in a realistic full Design Load Basis (DLB) for the DTU 10MW Reference Wind Turbine (RWT) model and for an upscaled rotor version in DTU's aeroelastic code HAWC2. The flap system implementation shows considerable potential in reducing extreme loads in components of interest including the blades, main bearing and tower top, with no influence on fatigue loads and power performance. In addition, an individual flap controller for fatigue load reduction in above rated power conditions is also implemented and integrated in the general controller architecture. The system is shown to be a technology enabler for rotor upscaling, by combining extreme and fatigue load reduction.

  2. Does adding antibiotics to cement reduce the need for early revision in total knee arthroplasty?

    PubMed

    Bohm, Eric; Zhu, Naisu; Gu, Jing; de Guia, Nicole; Linton, Cassandra; Anderson, Tammy; Paton, David; Dunbar, Michael

    2014-01-01

    There is considerable debate about whether antibiotic-loaded bone cement should be used for fixation of TKAs. While antibiotics offer the theoretical benefit of lowering early revision due to infection, they may weaken the cement and thus increase the likelihood of aseptic loosening, perhaps resulting in a higher revision rate. We (1) compared the frequency of early knee revision arthroplasty in patients treated with antibiotic-loaded or non-antibiotic-loaded cement for initial fixation, (2) determined effects of age, sex, comorbidities, and surgeons' antibiotic-loaded cement usage patterns on revision rate, and (3) compared causes of revision (aseptic or septic) between groups. Our study sample was taken from the Canadian Joint Replacement Registry and Canada's Hospital Morbidity Database and included cemented TKAs performed between April 1, 2003, and March 31, 2008, including 20,016 TKAs inserted with non-antibiotic-loaded cement and 16,665 inserted with antibiotic-loaded cement. Chi-square test was used to compare the frequency of early revisions between groups. Cox regression modeling was used to determine whether revision rate would change by age, sex, comorbidities, or use of antibiotic-loaded cement. Similar Cox regression modeling was used to compare cause of revision between groups. Two-year revision rates were similar between the groups treated with non-antibiotic-loaded cement and antibiotic-loaded cement (1.40% versus 1.51%, p = 0.41). When controlling for age, sex, comorbidities, diabetes, and surgeons' antibiotic-loaded cement usage patterns, the revision risk likewise was similar between groups. Revision rates for infection were similar between groups; however, there were more revisions for aseptic loosening in the group treated with non-antibiotic-loaded cement (p = 0.02). The use of antibiotic-loaded cement in TKAs performed for osteoarthritis has no clinically significant effect on reducing revision within 2 years in patients who received perioperative antibiotics. Longer followup and confirmation of these findings with other national registries are warranted.

  3. Childhood abuse and depression in adulthood: The mediating role of allostatic load.

    PubMed

    Scheuer, Sandra; Wiggert, Nicole; Brückl, Tanja Maria; Awaloff, Yvonne; Uhr, Manfred; Lucae, Susanne; Kloiber, Stefan; Holsboer, Florian; Ising, Marcus; Wilhelm, Frank H

    2018-04-22

    Traumatic experiences during childhood are considered a major risk factor for depression in adulthood. Childhood trauma may induce physiological dysregulation with long-term effects of increased allostatic load until adulthood, which may lead to depression. Thus, our aim was to investigate whether allostatic load - which represents a multi-system measure of physiological dysregulation - mediates the association between childhood trauma and adult depression. The study sample consisted of 324 depressed inpatients participating in the Munich Antidepressant Response Signature (MARS) project and 261 mentally healthy control participants. The mediation analysis using a case-control approach included childhood trauma, i.e., physical and sexual abuse, as predictor variables and an allostatic load index comprised of 12 stress-related biomarkers as mediator. Age and sex were included as covariates. Mediation analyses revealed that the influence of physical abuse, but not sexual abuse, during childhood on depression in adulthood was mediated by allostatic load. This effect was moderated by age: particularly young (18-42 years) and middle-aged (43-54 years) adults with a history of physical abuse during childhood exhibited high allostatic load, which in turn was associated with increased rates of depression, but this was not the case for older participants (55-81 years). Results support the theoretical assumption of allostatic load mediating the effect of physical abuse during childhood on depression in adulthood. This predominantly holds for younger participants, while depression in older participants was independent of physical abuse and allostatic load. The effect of sexual abuse on depression, however, was not mediated by allostatic load. Identifying allostatic load biomarkers prospectively in the developmental course of depression is an important target for future research. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Calculating Nozzle Side Loads using Acceleration Measurements of Test-Based Models

    NASA Technical Reports Server (NTRS)

    Brown, Andrew M.; Ruf, Joe

    2007-01-01

    As part of a NASA/MSFC research program to evaluate the effect of different nozzle contours on the well-known but poorly characterized "side load" phenomena, we attempt to back out the net force on a sub-scale nozzle during cold-flow testing using acceleration measurements. Because modeling the test facility dynamics is problematic, new techniques for creating a "pseudo-model" of the facility and nozzle directly from modal test results are applied. Extensive verification procedures were undertaken, resulting in a loading scale factor necessary for agreement between test and model based frequency response functions. Side loads are then obtained by applying a wide-band random load onto the system model, obtaining nozzle response PSD's, and iterating both the amplitude and frequency of the input until a good comparison of the response with the measured response PSD for a specific time point is obtained. The final calculated loading can be used to compare different nozzle profiles for assessment during rocket engine nozzle development and as a basis for accurate design of the nozzle and engine structure to withstand these loads. The techniques applied within this procedure have extensive applicability to timely and accurate characterization of all test fixtures used for modal test.A viewgraph presentation on a model-test based pseudo-model used to calculate side loads on rocket engine nozzles is included. The topics include: 1) Side Loads in Rocket Nozzles; 2) Present Side Loads Research at NASA/MSFC; 3) Structural Dynamic Model Generation; 4) Pseudo-Model Generation; 5) Implementation; 6) Calibration of Pseudo-Model Response; 7) Pseudo-Model Response Verification; 8) Inverse Force Determination; 9) Results; and 10) Recent Work.

  5. 14 CFR 23.307 - Proof of structure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    .... Dynamic tests, including structural flight tests, are acceptable if the design load conditions have been... critical load condition. Structural analysis may be used only if the structure conforms to those for which...

  6. Slow Crack Growth Analysis of Advanced Structural Ceramics Under Combined Loading Conditions: Damage Assessment in Life Prediction Testing

    NASA Technical Reports Server (NTRS)

    Choi, S. R.; Gyekenyesi, J. P.

    2001-01-01

    Slow crack growth analysis was performed with three different loading histories including constant stress- rate/constant stress-rate testing (Case I loading), constant stress/constant stress-rate testing (Case II loading), and cyclic stress/constant stress-rate testing (Case III loading). Strength degradation due to slow crack growth and/or damage accumulation was determined numerically as a function of percentage of interruption time between the two loading sequences for a given loading history. The numerical solutions were examined with the experimental data determined at elevated temperatures using four different advanced ceramic materials, two silicon nitrides, one silicon carbide and one alumina for the Case I loading history, and alumina for the Case II loading history. The numerical solutions were in reasonable agreement with the experimental data, indicating that notwithstanding some degree of creep deformation presented for some test materials slow crack growth was a governing mechanism associated with failure for all the rest materials.

  7. Slow Crack Growth Analysis of Advanced Structural Ceramics Under Combined Loading Conditions: Damage Assessment in Life Prediction Testing

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Gyekenyesi, John P.

    2000-01-01

    Slow crack growth analysis was performed with three different loading histories including constant stress-rate/constant stress-rate testing (Case 1 loading), constant stress/constant stress-rate testing (Case 2 loading), and cyclic stress/constant stress-rate testing (Case 2 loading). Strength degradation due to slow crack growth and/or damage accumulation was determined numerically as a function of percentage of interruption time between the two loading sequences for a given loading history. The numerical solutions were examined with the experimental data determined at elevated temperatures using four different advanced ceramic materials, two silicon nitrides, one silicon carbide and one alumina for the Case 1 loading history, and alumina for the Case 3 loading history. The numerical solutions were in reasonable agreement with the experimental data, indicating that notwithstanding some degree of creep deformation presented for some test materials slow crack growth was a governing mechanism associated with failure for all the test materials.

  8. Slow Crack Growth Analysis of Advanced Structural Ceramics Under Combined Loading Conditions: Damage Assessment in Life Prediction Testing

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Gyekenyesi, John P.

    2000-01-01

    Slow crack growth analysis was performed with three different loading histories including constant stress-rate/constant stress-rate testing (Case I loading), constant stress/constant stress-rate testing (Case II loading), and cyclic stress/constant stress-rate testing (Case III loading). Strength degradation due to slow crack growth arid/or damage accumulation was determined numerically as a Function of percentage of interruption time between the two loading sequences for a given loading history. The numerical solutions were examined with the experimental data determined at elevated temperatures using four different advanced ceramic materials, two silicon nitrides, one silicon carbide and one alumina for the Case I loading history, and alumina for the Case II loading history. The numerical solutions were in reasonable agreement with the experimental data, indicating that notwithstanding some degree of creep deformation presented for some test materials slow crack growth was a governing mechanism associated with failure for all the test material&

  9. Estimating the Impacts of Direct Load Control Programs Using GridPIQ, a Web-Based Screening Tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pal, Seemita; Thayer, Brandon L.; Barrett, Emily L.

    In direct load control (DLC) programs, utilities can curtail the demand of participating loads to contractually agreed-upon levels during periods of critical peak load, thereby reducing stress on the system, generation cost, and required transmission and generation capacity. Participating customers receive financial incentives. The impacts of implementing DLC programs extend well beyond peak shaving. There may be a shift of load proportional to the interrupted load to the times before or after a DLC event, and different load shifts have different consequences. Tools that can quantify the impacts of such programs on load curves, peak demand, emissions, and fossil fuelmore » costs are currently lacking. The Grid Project Impact Quantification (GridPIQ) screening tool includes a Direct Load Control module, which takes into account project-specific inputs as well as the larger system context in order to quantify the impacts of a given DLC program. This allows users (utilities, researchers, etc.) to test and compare different program specifications and their impacts.« less

  10. SSME turbopump bearing analytical study

    NASA Technical Reports Server (NTRS)

    Kannel, J. W.; Merriman, T.

    1980-01-01

    Three shuttle pump bearings operating under severe overspeed and shut-down conditions are evaluated. The specific parameters investigated include outer race stresses, cage stresses, cage-race drag, bearing heating, and crush loading. A quasi-dynamic version of the BASDAP computer code was utilized which involved the calculation of ball-race forces (inner and outer), contact pressures, contact dimensions, and contact angles as a function of (1) axial load, (2) radial load, and (3) centrifugal load on the bearing. Generally, radial loads on the order of 13,300 N (3000 pounds) per bearing or 26,700 N (6000 pounds) per bearing pair, could be expected to cause severe problems to any of the bearings with a 17,800 N (4000 pounds) axial load. Further, when possible temperature excursions are considered, even a load of 8900 N (2000 pounds) may be excessive. However, high momentary radial loads with a 3800 N (850 pounds) axial load would not be anticipated to cause catastrophic failure of the fuel pump bearing.

  11. 49 CFR 571.120 - Tire selection and rims and motor home/recreation vehicle trailer load carrying capacity...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...: XXX kg or XXX lbs” in block letters with appropriate values included. (d) The statement “Safety belt equipped seating capacity: XXX” with the appropriate value included. This is the total number of safety belt equipped seating positions. (e) The statement: “CAUTION: A full load of water equals XXX kg or XXX...

  12. 49 CFR 571.120 - Tire selection and rims and motor home/recreation vehicle trailer load carrying capacity...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...: XXX kg or XXX lbs” in block letters with appropriate values included. (d) The statement “Safety belt equipped seating capacity: XXX” with the appropriate value included. This is the total number of safety belt equipped seating positions. (e) The statement: “CAUTION: A full load of water equals XXX kg or XXX...

  13. 49 CFR 571.120 - Tire selection and rims and motor home/recreation vehicle trailer load carrying capacity...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...: XXX kg or XXX lbs” in block letters with appropriate values included. (d) The statement “Safety belt equipped seating capacity: XXX” with the appropriate value included. This is the total number of safety belt equipped seating positions. (e) The statement: “CAUTION: A full load of water equals XXX kg or XXX...

  14. 49 CFR 571.120 - Tire selection and rims and motor home/recreation vehicle trailer load carrying capacity...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...: XXX kg or XXX lbs” in block letters with appropriate values included. (d) The statement “Safety belt equipped seating capacity: XXX” with the appropriate value included. This is the total number of safety belt equipped seating positions. (e) The statement: “CAUTION: A full load of water equals XXX kg or XXX...

  15. Chapel branch creek TMDL development: integrating TMDL development with implementation

    Treesearch

    T.M. Williams; D.M. Amatya; D.R. Hitchcock; N. Levine; E.N. Mihalik

    2007-01-01

    South Carolina assured the USEPA "The State intends to achieve waste load and load allocation reductions in 303(d) listed waters in order to achieve the water quality goals of the Clean Water Act. This includes waters impaired solely or primarily by NPS sources. For each such water, a TMDL will be established that includes specific recommendations for reducing...

  16. 49 CFR 178.345-6 - Supports and anchoring.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... support elements must include the stresses indicated in § 178.345-3(b) and as generated by the loads... in lieu of a frame must be supported in such a manner that the resulting stress levels in the cargo... must include the stresses indicated in § 178.345-3(b) and as generated by the loads described in § 178...

  17. Thermal load histories for North American roof assembles using various cladding materials including wood-thermoplastic composite shingles

    Treesearch

    J. E. Winandy

    2006-01-01

    Since 1991, thermal load histories for various roof cladding types have been monitored in outdoor attic structures that simulate classic North American light-framed construction. In this paper, the 2005 thermal loads for wood-based composite roof sheathing, wood rafters, and attics under wood-plastic composite shingles are compared to common North American roof...

  18. Stereo photo series for quantifying natural fuels Volume IX: oak/juniper in southern Arizona and New Mexico.

    Treesearch

    Roger D. Ottmar; Robert E. Vihnanek; Clinton S. Wright; Geoffrey B. Seymour

    2007-01-01

    A series of single and stereo photographs display a range of natural conditions and fuel loadings in evergreen and deciduous oak/juniper woodland and savannah ecosystems in southern Arizona and New Mexico. This group of photos includes inventory data summarizing vegetation composition, structure, and loading; woody material loading and density by size class; forest...

  19. Effects of Cognitive Load on Trust

    DTIC Science & Technology

    2013-10-01

    that may be affected by load  Build a parsing tool to extract relevant features  Statistical analysis of results (by load components) Achieved...for a business application. Participants assessed potential job candidates and reviewed the applicants’ virtual resume which included standard...substantially different from each other that would make any confounding problems or other issues. Some statistics of the Australian data collection are

  20. Modeling Load Dynamics to Support Resiliency-based Operations in Low-Inertia Microgrids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tuffner, Francis K.; Schneider, Kevin P.; Hansen, Jacob

    Microgrids have repeatedly demonstrated the ability to provide uninterrupted service to critical end-use loads during normal outages, severe weather events, and natural disasters. While their ability to provide critical services is well documented, microgrids present a more dynamic operational environment than grid-connected distribution systems. The electrodynamics of a microgrid are commonly driven by the high inertia of rotating generators, which are common in many microgrids. In such high-inertia systems, the impact of end-use load electromechanical dynamics are often not examined. However, with the increased penetration of inverter-based generation with little or no inertia, it is necessary to consider the impactmore » that the dynamics of the end-use loads have on the operations of microgrids, particularly for a resiliency-based operation. These operations include, but are not limited to, switching operations, loss of generating units, and the starting of induction motors. This paper examines the importance of including multi-state electromechanical dynamic models of the end-use load when evaluating the operations of low inertia microgrids, and shows that by properly representing their behavior, it is possible to cost effectively size equipment while supporting resilient operations of critical end-use loads.« less

Top