Central obscuration effects on optical synthetic aperture imaging
NASA Astrophysics Data System (ADS)
Wang, Xue-wen; Luo, Xiao; Zheng, Li-gong; Zhang, Xue-jun
2014-02-01
Due to the central obscuration problem exists in most optical synthetic aperture systems, it is necessary to analyze its effects on their image performance. Based on the incoherent diffraction limited imaging theory, a Golay-3 type synthetic aperture system was used to study the central obscuration effects on the point spread function (PSF) and the modulation transfer function (MTF). It was found that the central obscuration does not affect the width of the central peak of the PSF and the cutoff spatial frequency of the MTF, but attenuate the first sidelobe of the PSF and the midfrequency of the MTF. The imaging simulation of a Golay-3 type synthetic aperture system with central obscuration proved this conclusion. At last, a Wiener Filter restoration algorithm was used to restore the image of this system, the images were obviously better.
Incoherent Diffractive Imaging via Intensity Correlations of Hard X Rays
NASA Astrophysics Data System (ADS)
Classen, Anton; Ayyer, Kartik; Chapman, Henry N.; Röhlsberger, Ralf; von Zanthier, Joachim
2017-08-01
Established x-ray diffraction methods allow for high-resolution structure determination of crystals, crystallized protein structures, or even single molecules. While these techniques rely on coherent scattering, incoherent processes like fluorescence emission—often the predominant scattering mechanism—are generally considered detrimental for imaging applications. Here, we show that intensity correlations of incoherently scattered x-ray radiation can be used to image the full 3D arrangement of the scattering atoms with significantly higher resolution compared to conventional coherent diffraction imaging and crystallography, including additional three-dimensional information in Fourier space for a single sample orientation. We present a number of properties of incoherent diffractive imaging that are conceptually superior to those of coherent methods.
MTF measurements of a type-II superlattice infrared focal plane array sealed in a cryocooler.
Nghiem, Jean; Jaeck, Julien; Primot, Jerome; Coudrain, Christophe; Derelle, Sophie; Huard, Edouard; Caes, Marcel; Bernhardt, Sylvie; Haidar, Riad; Christol, Philippe; Ribet-Mohamed, Isabelle
2018-04-16
In operational electro-optical systems, infrared focal plane arrays (IR FPA) are integrated in cryocoolers which induce vibrations that may strongly affect their modulation transfer function (MTF). In this paper, we present the MTF measurement of an IR FPA sealed in its cryocooler. The method we use to measure the MTF decorrelates operational constraints and the technological limitations of the IR FPA. The bench is based on the diffraction properties of a continuously self imaging grating (CSIG). The 26 µm pixel size extracted from the MTF measurement is in good agreement with the expected value.
Lappi, T.; Venugopalan, R.; Mantysaari, H.
2015-02-25
We argue that the proton multiplicities measured in Roman pot detectors at an electron ion collider can be used to determine centrality classes in incoherent diffractive scattering. Incoherent diffraction probes the fluctuations in the interaction strengths of multi-parton Fock states in the nuclear wavefunctions. In particular, the saturation scale that characterizes this multi-parton dynamics is significantly larger in central events relative to minimum bias events. As an application, we examine the centrality dependence of incoherent diffractive vector meson production. We identify an observable which is simultaneously very sensitive to centrality triggered parton fluctuations and insensitive to details of the model.
NASA Astrophysics Data System (ADS)
Sander, M.; Pudell, J.-E.; Herzog, M.; Bargheer, M.; Bauer, R.; Besse, V.; Temnov, V.; Gaal, P.
2017-12-01
We present time-resolved x-ray reflectivity measurements on laser excited coherent and incoherent surface deformations of thin metallic films. Based on a kinematical diffraction model, we derive the surface amplitude from the diffracted x-ray intensity and resolve transient surface excursions with sub-Å spatial precision and 70 ps temporal resolution. The analysis allows for decomposition of the surface amplitude into multiple coherent acoustic modes and a substantial contribution from incoherent phonons which constitute the sample heating.
Design and analysis of aspherical multilayer imaging X-ray microscope
NASA Technical Reports Server (NTRS)
Shealy, David L.; Jiang, WU; Hoover, Richard B.
1991-01-01
Spherical Schwarzschild microscopes for soft X-ray applications in microscopy and projection lithography employ two concentric spherical mirrors that are configured such that the third-order spherical aberration and coma are zero. Based on incoherent, sine-wave MTF calculations, the object-plane resolution of a magnification-factor-20 microscope is presently analyzed as a function of object height and numerical aperture of the primary for several spherical Schwarzschild, conic, and aspherical two-mirror microscope configurations.
Image contrast of diffraction-limited telescopes for circular incoherent sources of uniform radiance
NASA Technical Reports Server (NTRS)
Shackleford, W. L.
1980-01-01
A simple approximate formula is derived for the background intensity beyond the edge of the image of uniform incoherent circular light source relative to the irradiance near the center of the image. The analysis applies to diffraction-limited telescopes with or without central beam obscuration due to a secondary mirror. Scattering off optical surfaces is neglected. The analysis is expected to be most applicable to spaceborne IR telescopes, for which diffraction can be the major source of off-axis response.
Synthetic Incoherence via Scanned Gaussian Beams
Levine, Zachary H.
2006-01-01
Tomography, in most formulations, requires an incoherent signal. For a conventional transmission electron microscope, the coherence of the beam often results in diffraction effects that limit the ability to perform a 3D reconstruction from a tilt series with conventional tomographic reconstruction algorithms. In this paper, an analytic solution is given to a scanned Gaussian beam, which reduces the beam coherence to be effectively incoherent for medium-size (of order 100 voxels thick) tomographic applications. The scanned Gaussian beam leads to more incoherence than hollow-cone illumination. PMID:27274945
Selectivity analysis of an incoherent grating imaged in a photorefractive crystal
NASA Astrophysics Data System (ADS)
Tebaldi, Myrian; Forte, Gustavo; Bolognini, Nestor; Lasprilla A., Maria del Carmen
2018-04-01
In this work, the diffraction efficiency of a volume phase grating incoherently stored in a photorefractive BSO crystal is theoretically and experimentally analyzed. The results confirm the theoretical proposal based on the coupled wave theory adopting a new grating depth parameter associated to the write-in incoherent optical system. The selectivity behavior is governed by the exit pupil diameter of the imaging recording system that controls the depth of the tridimensional image distribution along the propagation direction. Two incoherent gratings are multiplexed in a single crystal and reconstructed without cross-talk.
Chevret, P
2015-01-01
Sound prediction in open-plan offices is a real challenge for room acoustics models because of the large dimensions involved and because of the complexity of the interior layout. For these reasons, the geometrical theory, based on a high frequency hypothesis, is often cited as an advantageous solution. Two types of approaches are, in general, developed under this hypothesis: the phase-included approach and the energy-based or "incoherent" approach. In this paper, comparisons are presented between calculations performed using these two approaches and measurements conducted in the laboratory where workstations were separated by low dividers and placed under ceilings that were absorbent to various extents. Particular attention was paid to processing diffraction using the uniform theory of diffraction. Narrow-band comparisons between calculations and measurements show that the phase-included model is flawed at low frequencies whenever the characteristic dimensions of the elements of the room (desk, low divider, etc.) are of the same order of magnitude as the wavelength. Conversely, the incoherent formulation, which removes the part played by the interference, gives results at least as accurate, be it in octave band or overall. Boasting very short computation times, the incoherent approach opens up interesting prospects for acoustic predictions in large open-plan offices.
NASA Astrophysics Data System (ADS)
Pustozerov, A.; Shandarov, V.
2017-12-01
The influence of incoherent background illumination produced by light-emitting diodes (LED's) of different average wavelengths and laser diode emitting in blue region of visible on diffraction characteristics of narrow coherent light beams of He-Ne laser due to refractive index changes of Fe-doped lithium niobate sample are studied. It has been experimentally demonstrated that nonlinear diffraction of red beams with wavelength 633 nm and diameters on full width of half maximum (FWHM) near to 15 μm may be totally compensated using background light with average wavelengths 450 - 465 nm. To provide the necessary intensity of incoherent background, the combinations of spherical and cylindrical concave lenses with blue LED and laser diode module without focusing its beam have been used.
Spatial Phase Coding for Incoherent Optical Processors
NASA Technical Reports Server (NTRS)
Tigin, D. V.; Lavrentev, A. A.; Gary, C. K.
1994-01-01
In this paper we introduce spatial phase coding of incoherent optical signals for representing signed numbers in optical processors and present an experimental demonstration of this coding technique. If a diffraction grating, such as an acousto-optic cell, modulates a stream of light, the image of the grating can be recovered from the diffracted beam. The position of the grating image, or more precisely its phase, can be used to denote the sign of the number represented by the diffracted light. The intensity of the light represents the magnitude of the number. This technique is more economical than current methods in terms of the number of information channels required to represent a number and the amount of post processing required.
Evaluation of loss in optical quality of multifocal intraocular lenses with glistenings.
DeHoog, Edward; Doraiswamy, Anand
2016-04-01
To study the impact of loss in optical quality from glistenings in diffractive multifocal intraocular lenses (IOLs) using ray tracing in a model eye. Independent research laboratory, Irvine, California, USA. Experimental study. A pseudophakic eye model was constructed in Zemax, an optical ray-tracing program, using the Arizona eye model as the basis. The Mie scattering theory was used to describe the intensity and direction of light as it scattered for a spherical particle immersed in a diffractive multifocal IOL. To evaluate the impact of glistening scatter, a more advanced eye model was constructed in Fred, a nonsequential optical ray-tracing software. An evaluation of scatter and modulation transfer function (MTF) was performed for a hydrophobic biomaterial with a refractive index of 1.54 for various sizes and densities of glistenings under mesopic conditions. As predicted by the Mie theory, the amount of scatter was a function of the change in the refractive index, size of the scatterer, and volume fraction of the scatterers. This modeling showed that an increase in density of glistenings can lead to a significant drop of MTF of the IOL. This effect was more pronounced in multifocal IOLs than in monofocal IOLs. Mathematical modeling showed that glistenings in multifocal IOLs lead to a reduction in MTF of the IOL and the pseudophakic eye. The relative loss of MTF in multifocal IOLs was more significant than in monofocal IOLs because of the nature of the design. Drs. DeHoog and Doraiswamy are consultants to Advanced Vision Science, Inc. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
MTF evaluation of in-line phase contrast imaging system
NASA Astrophysics Data System (ADS)
Sun, Xiaoran; Gao, Feng; Zhao, Huijuan; Zhang, Limin; Li, Jiao; Zhou, Zhongxing
2017-02-01
X-ray phase contrast imaging (XPCI) is a novel method that exploits the phase shift for the incident X-ray to form an image. Various XPCI methods have been proposed, among which, in-line phase contrast imaging (IL-PCI) is regarded as one of the most promising clinical methods. The contrast of the interface is enhanced due to the introduction of the boundary fringes in XPCI, thus it is generally used to evaluate the image quality of XPCI. But the contrast is a comprehensive index and it does not reflect the information of image quality in the frequency range. The modulation transfer function (MTF), which is the Fourier transform of the system point spread function, is recognized as the metric to characterize the spatial response of conventional X-ray imaging system. In this work, MTF is introduced into the image quality evaluation of the IL-PCI system. Numerous simulations based on Fresnel - Kirchhoff diffraction theory are performed with varying system settings and the corresponding MTFs were calculated for comparison. The results show that MTF can provide more comprehensive information of image quality comparing to contrast in IL-PCI.
Multi-Sensor Fusion of Infrared and Electro-Optic Signals for High Resolution Night Images
Huang, Xiaopeng; Netravali, Ravi; Man, Hong; Lawrence, Victor
2012-01-01
Electro-optic (EO) image sensors exhibit the properties of high resolution and low noise level at daytime, but they do not work in dark environments. Infrared (IR) image sensors exhibit poor resolution and cannot separate objects with similar temperature. Therefore, we propose a novel framework of IR image enhancement based on the information (e.g., edge) from EO images, which improves the resolution of IR images and helps us distinguish objects at night. Our framework superimposing/blending the edges of the EO image onto the corresponding transformed IR image improves their resolution. In this framework, we adopt the theoretical point spread function (PSF) proposed by Hardie et al. for the IR image, which has the modulation transfer function (MTF) of a uniform detector array and the incoherent optical transfer function (OTF) of diffraction-limited optics. In addition, we design an inverse filter for the proposed PSF and use it for the IR image transformation. The framework requires four main steps: (1) inverse filter-based IR image transformation; (2) EO image edge detection; (3) registration; and (4) blending/superimposing of the obtained image pair. Simulation results show both blended and superimposed IR images, and demonstrate that blended IR images have better quality over the superimposed images. Additionally, based on the same steps, simulation result shows a blended IR image of better quality when only the original IR image is available. PMID:23112602
Multi-sensor fusion of infrared and electro-optic signals for high resolution night images.
Huang, Xiaopeng; Netravali, Ravi; Man, Hong; Lawrence, Victor
2012-01-01
Electro-optic (EO) image sensors exhibit the properties of high resolution and low noise level at daytime, but they do not work in dark environments. Infrared (IR) image sensors exhibit poor resolution and cannot separate objects with similar temperature. Therefore, we propose a novel framework of IR image enhancement based on the information (e.g., edge) from EO images, which improves the resolution of IR images and helps us distinguish objects at night. Our framework superimposing/blending the edges of the EO image onto the corresponding transformed IR image improves their resolution. In this framework, we adopt the theoretical point spread function (PSF) proposed by Hardie et al. for the IR image, which has the modulation transfer function (MTF) of a uniform detector array and the incoherent optical transfer function (OTF) of diffraction-limited optics. In addition, we design an inverse filter for the proposed PSF and use it for the IR image transformation. The framework requires four main steps: (1) inverse filter-based IR image transformation; (2) EO image edge detection; (3) registration; and (4) blending/superimposing of the obtained image pair. Simulation results show both blended and superimposed IR images, and demonstrate that blended IR images have better quality over the superimposed images. Additionally, based on the same steps, simulation result shows a blended IR image of better quality when only the original IR image is available.
Accurate and cost-effective MTF measurement system for lens modules of digital cameras
NASA Astrophysics Data System (ADS)
Chang, Gao-Wei; Liao, Chia-Cheng; Yeh, Zong-Mu
2007-01-01
For many years, the widening use of digital imaging products, e.g., digital cameras, has given rise to much attention in the market of consumer electronics. However, it is important to measure and enhance the imaging performance of the digital ones, compared to that of conventional cameras (with photographic films). For example, the effect of diffraction arising from the miniaturization of the optical modules tends to decrease the image resolution. As a figure of merit, modulation transfer function (MTF) has been broadly employed to estimate the image quality. Therefore, the objective of this paper is to design and implement an accurate and cost-effective MTF measurement system for the digital camera. Once the MTF of the sensor array is provided, that of the optical module can be then obtained. In this approach, a spatial light modulator (SLM) is employed to modulate the spatial frequency of light emitted from the light-source. The modulated light going through the camera under test is consecutively detected by the sensors. The corresponding images formed from the camera are acquired by a computer and then, they are processed by an algorithm for computing the MTF. Finally, through the investigation on the measurement accuracy from various methods, such as from bar-target and spread-function methods, it appears that our approach gives quite satisfactory results.
Constraints for proton structure fluctuations from exclusive scattering
NASA Astrophysics Data System (ADS)
Mäntysaari, H.; Schenke, B.
2017-08-01
We constrain the average density profile of the proton and the amount of event-by-event fluctuations by simultaneously calculating the coherent and incoherent exclusive diffractive vector meson production cross section in deep inelastic scattering. Working within the Color Glass Condensate picture, we find that the gluonic density of the proton must have large geometric fluctuations in order to describe the experimentally measured large incoherent cross section.
Probing subnucleon scale fluctuations in ultraperipheral heavy ion collisions
Mantysaari, Heikki; Schenke, Bjorn
2017-08-02
We show that introducing subnucleon scale fluctuations constrained by HERA diffractive J/Ψ production data significantly affects the incoherent diffractive J/Ψ production cross section in ul-traperipheral heavy ion collisions. We find that the inclusion of the additional fluctuations increases the ratio of the incoherent to the coherent cross section approximately by a factor of 2, and modifies the transverse momentum spectra of the produced J/Ψ at momenta larger than the scale that corresponds to the distance scale of the subnucleonic fluctuations. We present predictions for J/Ψ production in ultraperipheral heavy ion collisions at √sNN = 5.02 TeV at the LHC andmore » 200 GeV at RHIC.« less
Measuring the spatial resolution of an optical system in an undergraduate optics laboratory
NASA Astrophysics Data System (ADS)
Leung, Calvin; Donnelly, T. D.
2017-06-01
Two methods of quantifying the spatial resolution of a camera are described, performed, and compared, with the objective of designing an imaging-system experiment for students in an undergraduate optics laboratory. With the goal of characterizing the resolution of a typical digital single-lens reflex (DSLR) camera, we motivate, introduce, and show agreement between traditional test-target contrast measurements and the technique of using Fourier analysis to obtain the modulation transfer function (MTF). The advantages and drawbacks of each method are compared. Finally, we explore the rich optical physics at work in the camera system by calculating the MTF as a function of wavelength and f-number. For example, we find that the Canon 40D demonstrates better spatial resolution at short wavelengths, in accordance with scalar diffraction theory, but is not diffraction-limited, being significantly affected by spherical aberration. The experiment and data analysis routines described here can be built and written in an undergraduate optics lab setting.
Evidence of strong proton shape fluctuations from incoherent diffraction
Mantysaari, H.; Schenke, B.
2016-07-25
We show within the saturation framework that measurements of exclusive vector meson production at high energy provide evidence for strong geometric fluctuations of the proton. In comparison, the effect of saturation scale and color charge fluctuations is weak. This knowledge will allow detailed future measurements of the incoherent cross section to tightly constrain the fluctuating geometry of the proton as a function of the parton momentum fraction x.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shu, F.; Ramakrishnan, V.; Schoenborn, B.P.
1994-12-31
Neutron diffraction has become one of the best ways to study light atoms, such as hydrogens. Hydrogen however has a negative coherent scattering factor, and a large incoherent scattering factor, while deuterium has virtually no incoherent scattering, but a large positive coherent scattering factor. Beside causing high background due to its incoherent scattering, the negative coherent scattering of hydrogen tends to cancel out the positive contribution from other atoms in a neutron density map. Therefore a fully deuterated sample will yield better diffraction data with stronger density in the hydrogen position. On this basis, a sperm whale myoglobin gene modifiedmore » to include part of the A cII protein gene has been cloned into the T7 expression system. Milligram amounts of fully deuterated holo-myoglobin have been obtained and used for crystallization. The synthetic sperm whale myoglobin crystallized in P2{sub 1} space group isomorphous with the native protein crystal. A complete X-ray diffraction dataset at 1.5{Angstrom} has been collected. This X-ray dataset, and a neutron data set collected previously on a protonated carbon-monoxymyoglobin crystal have been used for solvent structure studies. Both X-ray and neutron data have shown that there are ordered hydration layers around the protein surface. Solvent shell analysis on the neutron data further has shown that the first hydration layer behaves differently around polar and apolar regions of the protein surface. Finally, the structure of per-deuterated myoglobin has been refined using all reflections to a R factor of 17%.« less
Evaluate depth of field limits of fixed focus lens arrangements in thermal infrared
NASA Astrophysics Data System (ADS)
Schuster, Norbert
2016-05-01
More and more modern thermal imaging systems use uncooled detectors. High volume applications work with detectors that have a reduced pixel count (typically between 200x150 and 640x480). This reduces the usefulness of modern image treatment procedures such as wave front coding. On the other hand, uncooled detectors demand lenses with fast fnumbers, near f/1.0, which reduces the expected Depth of Field (DoF). What are the limits on resolution if the target changes distance to the camera system? The desire to implement lens arrangements without a focusing mechanism demands a deeper quantification of the DoF problem. A new approach avoids the classic "accepted image blur circle" and quantifies the expected DoF by the Through Focus MTF of the lens. This function is defined for a certain spatial frequency that provides a straightforward relation to the pixel pitch of imaging device. A certain minimum MTF-level is necessary so that the complete thermal imaging system can realize its basic functions, such as recognition or detection of specified targets. Very often, this technical tradeoff is approved with a certain lens. But what is the impact of changing the lens for one with a different focal length? Narrow field lenses, which give more details of targets in longer distances, tighten the DoF problem. A first orientation is given by the hyperfocal distance. It depends in a square relation on the focal length and in a linear relation on the through focus MTF of the lens. The analysis of these relations shows the contradicting requirements between higher thermal and spatial resolution, faster f-number and desired DoF. Furthermore, the hyperfocal distance defines the DoF-borders. Their relation between is such as the first order imaging formulas. A calculation methodology will be presented to transfer DoF-results from an approved combination lens and camera to another lens in combination with the initial camera. Necessary input for this prediction is the accepted DoF of the initial combination and the through focus MTFs of both lenses. The accepted DoF of the initial combination defines an application and camera related MTF-level, which must be provided also by the new lens. Examples are provided. The formula of the Diffraction-Limited-Through-Focus-MTF (DLTF) quantifies the physical limit and works without any ray trace. This relation respects the pixel pitch, the waveband and the aperture based f-number, but is independent of detector size. The DLTF has a steeper slope than the ray traced Through-Focus-MTF; its maximum is the diffraction limit. The DLTF predicts the DoF-relations quite precisely. Differences to ray trace results are discussed. Last calculations with modern detectors show that a static chosen MTF-level doesn't reflect the reality for the DoFproblem. The MTF-level to respect depends on application, pixel pitch, IR-camera and image treatment. A value of 0.250 at the detector Nyquist frequency seems to be a reasonable starting point for uncooled FPAs with 17μm pixel pitch.
NASA Astrophysics Data System (ADS)
Pospisil, J.; Jakubik, P.; Machala, L.
2005-11-01
This article reports the suggestion, realization and verification of the newly developed measuring means of the noiseless and locally shift-invariant modulation transfer function (MTF) of a digital video camera in a usual incoherent visible region of optical intensity, especially of its combined imaging, detection, sampling and digitizing steps which are influenced by the additive and spatially discrete photodetector, aliasing and quantization noises. Such means relates to the still camera automatic working regime and static two-dimensional spatially continuous light-reflection random target of white-noise property. The introduced theoretical reason for such a random-target method is also performed under exploitation of the proposed simulation model of the linear optical intensity response and possibility to express the resultant MTF by a normalized and smoothed rate of the ascertainable output and input power spectral densities. The random-target and resultant image-data were obtained and processed by means of a processing and evaluational PC with computation programs developed on the basis of MATLAB 6.5E The present examples of results and other obtained results of the performed measurements demonstrate the sufficient repeatability and acceptability of the described method for comparative evaluations of the performance of digital video cameras under various conditions.
Optical design of laser zoom projective lens with variable total track
NASA Astrophysics Data System (ADS)
He, Yulan; Xiao, Xiangguo; Lu, Feng; Li, Yuan; Han, Kunye; Wang, Nanxi; Qiang, Hua
2017-02-01
In order to project the laser command information to the proper distance , so a laser zoom projective lens with variable total track optical system is designed in the carrier-based aircraft landing system. By choosing the zoom structure, designing of initial structure with PW solution, correcting and balancing the aberration, a large variable total track with 35 × zoom is carried out. The size of image is invariable that is φ25m, the distance of projective image is variable from 100m to 3500m. Optical reverse design, the spot is less than 8μm, the MTF is near the diffraction limitation, the value of MTF is bigger than 0.4 at 50lp/mm.
von Olshausen, Philipp; Rohrbach, Alexander
2013-10-15
Coherent imaging is barely applicable in life-science microscopy due to multiple interference artifacts. Here, we show how these interferences can be used to improve image resolution and contrast. We present a dark-field microscopy technique with evanescent illumination via total internal reflection that delivers high-contrast images of coherently scattering samples. By incoherent averaging of multiple coherent images illuminated from different directions we can resolve image structures that remain unresolved by conventional (incoherent) fluorescence microscopy. We provide images of 190 nm beads revealing resolution beyond the diffraction limit and slightly increased object distances. An analytical model is introduced that accounts for the observed effects and which is confirmed by numerical simulations. Our approach may be a route to fast, label-free, super-resolution imaging in live-cell microscopy.
Detection of a Novel Mechanism of Acousto-Optic Modulation of Incoherent Light
Jarrett, Christopher W.; Caskey, Charles F.; Gore, John C.
2014-01-01
A novel form of acoustic modulation of light from an incoherent source has been detected in water as well as in turbid media. We demonstrate that patterns of modulated light intensity appear to propagate as the optical shadow of the density variations caused by ultrasound within an illuminated ultrasonic focal zone. This pattern differs from previous reports of acousto-optical interactions that produce diffraction effects that rely on phase shifts and changes in light directions caused by the acoustic modulation. Moreover, previous studies of acousto-optic interactions have mainly reported the effects of sound on coherent light sources via photon tagging, and/or the production of diffraction phenomena from phase effects that give rise to discrete sidebands. We aimed to assess whether the effects of ultrasound modulation of the intensity of light from an incoherent light source could be detected directly, and how the acoustically modulated (AOM) light signal depended on experimental parameters. Our observations suggest that ultrasound at moderate intensities can induce sufficiently large density variations within a uniform medium to cause measurable modulation of the intensity of an incoherent light source by absorption. Light passing through a region of high intensity ultrasound then produces a pattern that is the projection of the density variations within the region of their interaction. The patterns exhibit distinct maxima and minima that are observed at locations much different from those predicted by Raman-Nath, Bragg, or other diffraction theory. The observed patterns scaled appropriately with the geometrical magnification and sound wavelength. We conclude that these observed patterns are simple projections of the ultrasound induced density changes which cause spatial and temporal variations of the optical absorption within the illuminated sound field. These effects potentially provide a novel method for visualizing sound fields and may assist the interpretation of other hybrid imaging methods. PMID:25105880
Optimization of wavefront coding imaging system using heuristic algorithms
NASA Astrophysics Data System (ADS)
González-Amador, E.; Padilla-Vivanco, A.; Toxqui-Quitl, C.; Zermeño-Loreto, O.
2017-08-01
Wavefront Coding (WFC) systems make use of an aspheric Phase-Mask (PM) and digital image processing to extend the Depth of Field (EDoF) of computational imaging systems. For years, several kinds of PM have been designed to produce a point spread function (PSF) near defocus-invariant. In this paper, the optimization of the phase deviation parameter is done by means of genetic algorithms (GAs). In this, the merit function minimizes the mean square error (MSE) between the diffraction limited Modulated Transfer Function (MTF) and the MTF of the system that is wavefront coded with different misfocus. WFC systems were simulated using the cubic, trefoil, and 4 Zernike polynomials phase-masks. Numerical results show defocus invariance aberration in all cases. Nevertheless, the best results are obtained by using the trefoil phase-mask, because the decoded image is almost free of artifacts.
NASA Astrophysics Data System (ADS)
Dorofeyev, Illarion
2008-08-01
The classical Kirchhoff theory of diffraction is extended to the case of real optical properties of a screen and its finite thickness. A spectral power density of diffracted electromagnetic fields by a hole in a thin film with real optical properties was calculated. The problem was solved by use of the vector Green theorems and related Green function of the boundary value problem. A spectral and spatial selectivity of the considered system was demonstrated. Diffracted patterns were calculated for the coherent and incoherent incident fields in case of holes array in a screen of perfect conductivity.
Subdiffraction incoherent optical imaging via spatial-mode demultiplexing: Semiclassical treatment
NASA Astrophysics Data System (ADS)
Tsang, Mankei
2018-02-01
I present a semiclassical analysis of a spatial-mode demultiplexing (SPADE) measurement scheme for far-field incoherent optical imaging under the effects of diffraction and photon shot noise. Building on previous results that assume two point sources or the Gaussian point-spread function, I generalize SPADE for a larger class of point-spread functions and evaluate its errors in estimating the moments of an arbitrary subdiffraction object. Compared with the limits to direct imaging set by the Cramér-Rao bounds, the results show that SPADE can offer far superior accuracy in estimating second- and higher-order moments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Chi, E-mail: chizheung@gmail.com; Xu, Yiqing; Wei, Xiaoming
2014-07-28
Time-stretch microscopy has emerged as an ultrafast optical imaging concept offering the unprecedented combination of the imaging speed and sensitivity. However, dedicated wideband and coherence optical pulse source with high shot-to-shot stability has been mandated for time-wavelength mapping—the enabling process for ultrahigh speed wavelength-encoded image retrieval. From the practical point of view, exploiting methods to relax the stringent requirements (e.g., temporal stability and coherence) for the source of time-stretch microscopy is thus of great value. In this paper, we demonstrated time-stretch microscopy by reconstructing the time-wavelength mapping sequence from a wideband incoherent source. Utilizing the time-lens focusing mechanism mediated bymore » a narrow-band pulse source, this approach allows generation of a wideband incoherent source, with the spectral efficiency enhanced by a factor of 18. As a proof-of-principle demonstration, time-stretch imaging with the scan rate as high as MHz and diffraction-limited resolution is achieved based on the wideband incoherent source. We note that the concept of time-wavelength sequence reconstruction from wideband incoherent source can also be generalized to any high-speed optical real-time measurements, where wavelength is acted as the information carrier.« less
Design, assembly, and metrology of an oil-immersion microscope objective with long working distance
NASA Astrophysics Data System (ADS)
Peng, Wei-Jei; Lin, Wen-Lung; Kuo, Hui-Jean; Ho, Cheng-Fang; Hsu, Wei-Yao
2016-10-01
The design, tolerance sensitivity reduction, assembly, and optical bench test for an oil-immersion microscope objective with long working distance employed in a lattice light-sheet microscope is presented in this paper. In this application, the orthogonal excitation and detection objectives are dipped in an oil medium. The excitation objective focuses the incident laser beam to generate fluorescence on specimen for collecting by detection objective. The excitation objective is custom-designed to meet the requirement specification such as oil-immersion, the long working distance, and numerical aperture (NA) of 0.5, etc. To produce an acceptable point spread function (PSF) for effective excitation, the performance of the objective needs to be close to diffraction limit. Because the tolerance of the modulation transfer function (MTF) is more and more sensitive at higher spatial frequency, it is extremely critical to keep the performance after manufacture. Consequently, an insensitive optical design is very important for relaxing tolerance. We compare the design with and without tolerance sensitivity reduction, and the as-built MTF shows the result. Furthermore, the method for sensitivity reduction is presented. The opto-mechanical design and assembly method are also discussed. Eventually, the objective with five spherical lenses was fabricated. In optical bench test, the depth of the oil is sensitive to MTF, and it leads to the complicated adjustment. For solving this issue, we made an index-matching lens to replace oil for measurement easily. Finally, the measured MTF of the excitation objective can accomplish the requirement specification and successfully employed in a lattice light-sheet microscope.
Image degradation characteristics and restoration based on regularization for diffractive imaging
NASA Astrophysics Data System (ADS)
Zhi, Xiyang; Jiang, Shikai; Zhang, Wei; Wang, Dawei; Li, Yun
2017-11-01
The diffractive membrane optical imaging system is an important development trend of ultra large aperture and lightweight space camera. However, related investigations on physics-based diffractive imaging degradation characteristics and corresponding image restoration methods are less studied. In this paper, the model of image quality degradation for the diffraction imaging system is first deduced mathematically based on diffraction theory and then the degradation characteristics are analyzed. On this basis, a novel regularization model of image restoration that contains multiple prior constraints is established. After that, the solving approach of the equation with the multi-norm coexistence and multi-regularization parameters (prior's parameters) is presented. Subsequently, the space-variant PSF image restoration method for large aperture diffractive imaging system is proposed combined with block idea of isoplanatic region. Experimentally, the proposed algorithm demonstrates its capacity to achieve multi-objective improvement including MTF enhancing, dispersion correcting, noise and artifact suppressing as well as image's detail preserving, and produce satisfactory visual quality. This can provide scientific basis for applications and possesses potential application prospects on future space applications of diffractive membrane imaging technology.
IRIA State-of-the-Art Report: Optical-Mechanical, Active/Passive Imaging Systems. Volume I.
1982-05-01
mostly nonimage -forming. With few exceptions, these devices used reflective optical systems, similar detectors (thermistor bolometers), and oscillating...diffraction-limited circular optics appears as a bright circular disk surrounded by concentric rings of diminishing flux density. The central disk...bar target is heavily concentrated in frequencies lower than the basic frequency of the bar target. The MTF of a reflective optical system varies as a
X ray microscope assembly and alignment support and advanced x ray microscope design and analysis
NASA Technical Reports Server (NTRS)
Shealy, David L.
1991-01-01
Considerable efforts have been devoted recently to the design, analysis, fabrication, and testing of spherical Schwarzschild microscopes for soft x ray application in microscopy and projection lithography. The spherical Schwarzschild microscope consists of two concentric spherical mirrors configured such that the third order spherical aberration and coma are zero. Since multilayers are used on the mirror substrates for x ray applications, it is desirable to have only two reflecting surfaces in a microscope. In order to reduce microscope aberrations and increase the field of view, generalized mirror surface profiles have been considered in this investigation. Based on incoherent and sine wave modulation transfer function (MTF) calculations, the object plane resolution of a microscope has been analyzed as a function of the object height and numerical aperture (NA) of the primary for several spherical Schwarzschild, conic, and aspherical head reflecting two mirror microscope configurations.
Target recognition and phase acquisition by using incoherent digital holographic imaging
NASA Astrophysics Data System (ADS)
Lee, Munseob; Lee, Byung-Tak
2017-05-01
In this study, we proposed the Incoherent Digital Holographic Imaging (IDHI) for recognition and phase information of dedicated target. Although recent development of a number of target recognition techniques such as LIDAR, there have limited success in target discrimination, in part due to low-resolution, low scanning speed, and computation power. In the paper, the proposed system consists of the incoherent light source, such as LED, Michelson interferometer, and digital CCD for acquisition of four phase shifting image. First of all, to compare with relative coherence, we used a source as laser and LED, respectively. Through numerical reconstruction by using the four phase shifting method and Fresnel diffraction method, we recovered the intensity and phase image of USAF resolution target apart from about 1.0m distance. In this experiment, we show 1.2 times improvement in resolution compared to conventional imaging. Finally, to confirm the recognition result of camouflaged targets with the same color from background, we carry out to test holographic imaging in incoherent light. In this result, we showed the possibility of a target detection and recognition that used three dimensional shape and size signatures, numerical distance from phase information of obtained holographic image.
NASA Astrophysics Data System (ADS)
Pitney, John Allen
Conventional x-ray diffraction has historically been done under conditions such that the measured signal consists of an incoherent addition of scattering which is coherent only on a length scale determined by the properties of the beam. The result of the incoherent summation is a statistical averaging over the whole illuminated volume of the sample, which yields certain kinds of information with a high degree of precision and has been key to the success of x-ray diffraction in a variety of applications. Coherent x-ray scattering techniques, such as coherent x-ray diffraction (CXD) and x-ray intensity fluctuation spectroscopy (XIFS), attempt to reduce or eliminate any incoherent averaging so that specific, local structures couple to the measurement without being averaged out. In the case of XIFS, the result is analogous to dynamical light scattering, but with sensitivity to length scales less than 200 nm and time scales from 10-3 s to 103 s. When combined with phase retrieval, CXD represents an imaging technique with the penetration, in situ capabilities, and contrast mechanisms associated with x-rays and with a spatial resolution ultimately limited by the x-ray wavelength. In practice, however, the spatial resolution of CXD imaging is limited by exposure to about 100 A. This thesis describes CXD measurements of the binary alloy Cu3Au and the adaptation of phase retrieval methods for the reconstruction of real-space images of Cu3Au antiphase domains. The theoretical foundations of CXD are described in Chapter 1 as derived from the kinematical formulation for x-ray diffraction and from the temporal and spatial coherence of radiation. The antiphase domain structure of Cu 3Au is described, along with the associated reciprocal-space structure which is measured by CXD. CXD measurements place relatively stringent requirements on the coherence properties of the beam and on the detection mechanism of the experiment; these requirements and the means by which they have been met are delineated in Chapter 2. The results and interpretation of a set of Cu 3Au measurements are presented in Chapter 3. Chapter 4 describes the Gerchberg-Saxton and the hybrid input-output (HIO) algorithms for phase retrieval and shows the results of image reconstruction tests with simulated Cu 3Au CXD, including the effect of oversampling in reciprocal space.
Liao, Xuan; Lin, Jia; Tian, Jing; Wen, BaiWei; Tan, QingQing; Lan, ChangJun
2018-06-01
To compare objective optical quality, ocular scattering and aberrations of eyes implanted with an aspheric monofocal intraocular lens (IOL) or an aspheric apodized diffractive multifocal IOL three months after surgery. Prospective consecutive nonrandomized comparative cohort study. A total of 80 eyes from 57 cataract patients were bilaterally or unilaterally implanted with monofocal (AcrySof IQ SN60WF) or multifocal (AcrySof IQ ReSTOR SN6AD1) IOLs. Respectively, 40 eyes of 27 patients were implanted with monofocal IOLs, and 40 eyes of 30 patients were implanted with multifocal IOLs. Ocular high-order aberration (HOA) values were obtained using Hartmann-Shack aberrometer; objective scatter index (OSI), modulation transfer function (MTF) cutoff, Strehl ratio (SR), and contrast visual acuity OV at 100%, 20%, and 9% were measured using Objective Quality Analysis System II (OQAS II). Ocular aberrations performed similar in both groups (p > 0.05). However, significantly higher values of OSI and lower values of MTF cutoff, SR and OV were found in the SN6AD1 group (p < 0.05). Both ocular scattering and wave-front aberrations play essential role in retinal image quality, which may be overestimated when only aberrations were taken into account. Combining the effect of ocular scattering with HOA will result in a more accurate assessment of the visual and optical quality.
Revealing proton shape fluctuations with incoherent diffraction at high energy
Mantysaari, H.; Schenke, B.
2016-08-30
The di erential cross section of exclusive di ractive vector meson production in electron proton collisions carries important information on the geometric structure of the proton. More speci cally, the coherent cross section as a function of the transferred transverse momentum is sensitive to the size of the proton, while the incoherent, or proton dissociative cross section is sensitive to uctuations of the gluon distribution in coordinate space. We show that at high energies the experimentally measured coherent and incoherent cross sections for the production of J= mesons are very well reproduced within the color glass condensate framework when strongmore » geometric uctuations of the gluon distribution in the proton are included. For meson production we also nd reasonable agreement. We study in detail the dependence of our results on various model parameters, including the average proton shape, analyze the e ect of saturation scale and color charge uctuations and constrain the degree of geometric uctuations.« less
Quantum imaging with incoherently scattered light from a free-electron laser
NASA Astrophysics Data System (ADS)
Schneider, Raimund; Mehringer, Thomas; Mercurio, Giuseppe; Wenthaus, Lukas; Classen, Anton; Brenner, Günter; Gorobtsov, Oleg; Benz, Adrian; Bhatti, Daniel; Bocklage, Lars; Fischer, Birgit; Lazarev, Sergey; Obukhov, Yuri; Schlage, Kai; Skopintsev, Petr; Wagner, Jochen; Waldmann, Felix; Willing, Svenja; Zaluzhnyy, Ivan; Wurth, Wilfried; Vartanyants, Ivan A.; Röhlsberger, Ralf; von Zanthier, Joachim
2018-02-01
The advent of accelerator-driven free-electron lasers (FEL) has opened new avenues for high-resolution structure determination via diffraction methods that go far beyond conventional X-ray crystallography methods. These techniques rely on coherent scattering processes that require the maintenance of first-order coherence of the radiation field throughout the imaging procedure. Here we show that higher-order degrees of coherence, displayed in the intensity correlations of incoherently scattered X-rays from an FEL, can be used to image two-dimensional objects with a spatial resolution close to or even below the Abbe limit. This constitutes a new approach towards structure determination based on incoherent processes, including fluorescence emission or wavefront distortions, generally considered detrimental for imaging applications. Our method is an extension of the landmark intensity correlation measurements of Hanbury Brown and Twiss to higher than second order, paving the way towards determination of structure and dynamics of matter in regimes where coherent imaging methods have intrinsic limitations.
The investigation of large field of view eyepiece with multilayer diffractive optical element
NASA Astrophysics Data System (ADS)
Fan, Changjiang
2014-11-01
In this paper, a light-small hybrid refractive/diffractive eyepiece for HMD is designed, which introduces a multilayer Diffractive Optical Element for the first time. This eyepiece optical system has a 22mm eye relief and 8mm exit pupil with 60° FOV. The multilayer DOE overcomes the difficulties of single-layer DOE and double-layer DOE using in the optical system, and improve the image contrast and the performance significantly due to the diffraction efficiency of the multilayer DOE is lager than 90% in wide waveband and large FOV range. The material of multilayer DOE are FCD1 for first layer, FD6 for second layer, PS for the filler layer. Moreover, the weight of the eyepiece system is only 8g, and the diameter of lens is 16mm. The MTF performance can satisfy the requirement of display with VGA resolution. Besides, the lateral color and distortion are 4.8% and 10μm, respectively. The properties of the helmet eyepiece system are excellent.
The partial coherence modulation transfer function in testing lithography lens
NASA Astrophysics Data System (ADS)
Huang, Jiun-Woei
2018-03-01
Due to the lithography demanding high performance in projection of semiconductor mask to wafer, the lens has to be almost free in spherical and coma aberration, thus, in situ optical testing for diagnosis of lens performance has to be established to verify the performance and to provide the suggesting for further improvement of the lens, before the lens has been build and integrated with light source. The measurement of modulation transfer function of critical dimension (CD) is main performance parameter to evaluate the line width of semiconductor platform fabricating ability for the smallest line width of producing tiny integrated circuits. Although the modulation transfer function (MTF) has been popularly used to evaluation the optical system, but in lithography, the contrast of each line-pair is in one dimension or two dimensions, analytically, while the lens stand along in the test bench integrated with the light source coherent or near coherent for the small dimension near the optical diffraction limit, the MTF is not only contributed by the lens, also by illumination of platform. In the study, the partial coherence modulation transfer function (PCMTF) for testing a lithography lens is suggested by measuring MTF in the high spatial frequency of in situ lithography lens, blended with the illumination of partial and in coherent light source. PCMTF can be one of measurement to evaluate the imperfect lens of lithography lens for further improvement in lens performance.
Optimal wavefront estimation of incoherent sources
NASA Astrophysics Data System (ADS)
Riggs, A. J. Eldorado; Kasdin, N. Jeremy; Groff, Tyler
2014-08-01
Direct imaging is in general necessary to characterize exoplanets and disks. A coronagraph is an instrument used to create a dim (high-contrast) region in a star's PSF where faint companions can be detected. All coronagraphic high-contrast imaging systems use one or more deformable mirrors (DMs) to correct quasi-static aberrations and recover contrast in the focal plane. Simulations show that existing wavefront control algorithms can correct for diffracted starlight in just a few iterations, but in practice tens or hundreds of control iterations are needed to achieve high contrast. The discrepancy largely arises from the fact that simulations have perfect knowledge of the wavefront and DM actuation. Thus, wavefront correction algorithms are currently limited by the quality and speed of wavefront estimates. Exposures in space will take orders of magnitude more time than any calculations, so a nonlinear estimation method that needs fewer images but more computational time would be advantageous. In addition, current wavefront correction routines seek only to reduce diffracted starlight. Here we present nonlinear estimation algorithms that include optimal estimation of sources incoherent with a star such as exoplanets and debris disks.
Kumar, Manoj; Vijayakumar, A; Rosen, Joseph
2017-09-14
We present a lensless, interferenceless incoherent digital holography technique based on the principle of coded aperture correlation holography. The acquired digital hologram by this technique contains a three-dimensional image of some observed scene. Light diffracted by a point object (pinhole) is modulated using a random-like coded phase mask (CPM) and the intensity pattern is recorded and composed as a point spread hologram (PSH). A library of PSHs is created using the same CPM by moving the pinhole to all possible axial locations. Intensity diffracted through the same CPM from an object placed within the axial limits of the PSH library is recorded by a digital camera. The recorded intensity this time is composed as the object hologram. The image of the object at any axial plane is reconstructed by cross-correlating the object hologram with the corresponding component of the PSH library. The reconstruction noise attached to the image is suppressed by various methods. The reconstruction results of multiplane and thick objects by this technique are compared with regular lens-based imaging.
An alternative approach to depth of field which avoids the blur circle and uses the pixel pitch
NASA Astrophysics Data System (ADS)
Schuster, Norbert
2015-09-01
Modern thermal imaging systems apply more and more uncooled detectors. High volume applications work with detectors which have a reduced pixel count (typical between 200x150 and 640x480). This shrinks the application of modern image treatment procedures like wave front coding. On the other hand side, uncooled detectors demand lenses with fast F-numbers near 1.0. Which are the limits on resolution if the target to analyze changes its distance to the camera system? The aim to implement lens arrangements without any focusing mechanism demands a deeper quantification of the Depth of Field problem. The proposed Depth of Field approach avoids the classic "accepted image blur circle". It bases on a camera specific depth of focus which is transformed in the object space by paraxial relations. The traditional RAYLEIGH's -criterion bases on the unaberrated Point Spread Function and delivers a first order relation for the depth of focus. Hence, neither the actual lens resolution neither the detector impact is considered. The camera specific depth of focus respects a lot of camera properties: Lens aberrations at actual F-number, detector size and pixel pitch. The through focus MTF is the base of the camera specific depth of focus. It has a nearly symmetric course around the maximum of sharp imaging. The through focus MTF is considered at detector's Nyquist frequency. The camera specific depth of focus is this the axial distance in front and behind of sharp image plane where the through focus MTF is <0.25. This camera specific depth of focus is transferred in the object space by paraxial relations. It follows a general applicable Depth of Field diagram which could be applied to lenses realizing a lateral magnification range -0.05…0. Easy to handle formulas are provided between hyperfocal distance and the borders of the Depth of Field in dependence on sharp distances. These relations are in line with the classical Depth of Field-theory. Thermal pictures, taken by different IR-camera cores, illustrate the new approach. The quite often requested graph "MTF versus distance" choses the half Nyquist frequency as reference. The paraxial transfer of the through focus MTF in object space distorts the MTF-curve: hard drop at closer distances than sharp distance, smooth drop at further distances. The formula of a general Diffraction-Limited-Through-Focus-MTF (DLTF) is deducted. Arbitrary detector-lens combinations could be discussed. Free variables in this analysis are waveband, aperture based F-number (lens) and pixel pitch (detector). The DLTF- discussion provides physical limits and technical requirements. The detector development with pixel pitches smaller than captured wavelength in the LWIR-region generates a special challenge for optical design.
Cryo diffraction microscopy: Ice conditions and finite supports
Miao, H.; Downing, K.; Huang, X.; ...
2009-09-25
Using a signal-to-noise ratio estimation based on correlations between multiple simulated images, we compare the dose efficiency of two soft x-ray imaging systems: incoherent brightfield imaging using zone plate optics in a transmission x-ray microscope (TXM), and x-ray diffraction microscopy (XDM) where an image is reconstructed from the far-field coherent diffraction pattern. In XDM one must computationally phase weak diffraction signals; in TXM one suffers signal losses due to the finite numerical aperture and efficiency of the optics. In simulations with objects representing isolated cells such as yeast, we find that XDM has the potential for delivering equivalent resolution imagesmore » using fewer photons. This can be an important advantage for studying radiation-sensitive biological and soft matter specimens.« less
Saini, Neetu; Sodhi, Rupinder Kaur; Bajaj, Lotika; Pandey, Ravi Shankar; Jain, Upendra Kumar; Katare, Om Prakash; Madan, Jitender
2016-08-01
Metformin hydrochloride (MTF-HCl) is extensively recommended by physicians for the treatment of polycystic ovary syndrome (PCOS). Mechanistically, MTF-HCl activates AMP-dependent kinase-α (AMPK-α) pathway to decrease the glucose production, enhances fatty acid oxidation and elevates the uptake of glucose in tissues. However, despite favourable physicochemical properties, oral administration of MTF-HCl is associated with impaired bioavailability (50-60%), lactic-acidosis and frequent dosing (500mg 2-3 times a day) in PCOS that ultimately influence the patient compliance. Therefore, in present investigation, MTF-HCl loaded unmodified and cationic small unilamellar niosomes were separately amalgamated with thermosensitive gel (MTF-HCl-SUNs-Gel and MTF-HCl-C-SUNs-Gel) for the treatment of PCOS through vaginal route of administration. MTF-HCl-SUNs and MTF-HCl-C-SUNs were separately prepared by reverse phase evaporation method. The nanovesicle size and zeta-potential of MTF-HCl-C-SUNs were measured to be 210.3±14.8-nm (P<0.05) and +8.7±2.7-mV (P<0.001), significantly higher than 198.5±20.3-nm and -16.6±3.9-mV of MTF-HCl-SUNs, respectively. Moreover, promising results of in vitro characterization parameters like gelation time, gelling temperature, viscosity analysis, percent mucoadhesiveness and drug release of MTF-HCl-C-SUNs-Gel and MTF-HCl-SUNs-Gel ensured the candidature of tailored gels for further in vivo investigations. In this way, treatment of PCOS rats under scheduled dose-dosage regimen with oral MTF-HCl solution, intravaginal MTF-HCl-SUNs-Gel and intravaginal MTF-HCl-C-SUNs-gel exhibited remarkable alterations, recruitment and development of normal follicles in addition to normalization of level of various hormones in PCOS. In conclusion, MTF-C-SUNs-Gel has paved the way for developing intravaginal dosage form of MTF-HCl for the treatment of PCOS. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Choi, Taeyong; Xiong, Xiaoxiong; Wang, Zhipeng
2013-01-01
Spatial quality of an imaging sensor can be estimated by evaluating its modulation transfer function (MTF) from many different sources such as a sharp edge, a pulse target, or bar patterns with different spatial frequencies. These well-defined targets are frequently used for prelaunch laboratory tests, providing very reliable and accurate MTF measurements. A laboratory-quality edge input source was included in the spatial-mode operation of the Spectroradiometric Calibration Assembly (SRCA), which is one of the onboard calibrators of the Moderate Resolution Imaging Spectroradiometer (MODIS). Since not all imaging satellites have such an instrument, SRCA MTF estimations can be used as a reference for an on-orbit lunar MTF algorithm and results. In this paper, the prelaunch spatial quality characterization process from the Integrated Alignment Collimator and SRCA is briefly discussed. Based on prelaunch MTF calibration using the SRCA, a lunar MTF algorithm is developed and applied to the lifetime on-orbit Terra and Aqua MODIS lunar collections. In each lunar collection, multiple scan-directionMoon-to-background transition profiles are aligned by the subpixel edge locations from a parametric Fermi function fit. Corresponding accumulated edge profiles are filtered and interpolated to obtain the edge spread function (ESF). The MTF is calculated by applying a Fourier transformation on the line spread function through a simple differentiation of the ESF. The lifetime lunar MTF results are analyzed and filtered by a relationship with the Sun-Earth-MODIS angle. Finally, the filtered lunarMTF values are compared to the SRCA MTF results. This comparison provides the level of accuracy for on-orbit MTF estimations validated through prelaunch SRCA measurements. The lunar MTF values had larger uncertainty than the SRCA MTF results; however, the ratio mean of lunarMTF fit and SRCA MTF values is within 2% in the 250- and 500-m bands. Based on the MTF measurement uncertainty range, the suggested lunar MTF algorithm can be applied to any on-orbit imaging sensor with lunar calibration capability.
Incoherent beam combining based on the momentum SPGD algorithm
NASA Astrophysics Data System (ADS)
Yang, Guoqing; Liu, Lisheng; Jiang, Zhenhua; Guo, Jin; Wang, Tingfeng
2018-05-01
Incoherent beam combining (ICBC) technology is one of the most promising ways to achieve high-energy, near-diffraction laser output. In this paper, the momentum method is proposed as a modification of the stochastic parallel gradient descent (SPGD) algorithm. The momentum method can improve the speed of convergence of the combining system efficiently. The analytical method is employed to interpret the principle of the momentum method. Furthermore, the proposed algorithm is testified through simulations as well as experiments. The results of the simulations and the experiments show that the proposed algorithm not only accelerates the speed of the iteration, but also keeps the stability of the combining process. Therefore the feasibility of the proposed algorithm in the beam combining system is testified.
Optical information encryption based on incoherent superposition with the help of the QR code
NASA Astrophysics Data System (ADS)
Qin, Yi; Gong, Qiong
2014-01-01
In this paper, a novel optical information encryption approach is proposed with the help of QR code. This method is based on the concept of incoherent superposition which we introduce for the first time. The information to be encrypted is first transformed into the corresponding QR code, and thereafter the QR code is further encrypted into two phase only masks analytically by use of the intensity superposition of two diffraction wave fields. The proposed method has several advantages over the previous interference-based method, such as a higher security level, a better robustness against noise attack, a more relaxed work condition, and so on. Numerical simulation results and actual smartphone collected results are shown to validate our proposal.
Camera System MTF: combining optic with detector
NASA Astrophysics Data System (ADS)
Andersen, Torben B.; Granger, Zachary A.
2017-08-01
MTF is one of the most common metrics used to quantify the resolving power of an optical component. Extensive literature is dedicated to describing methods to calculate the Modulation Transfer Function (MTF) for stand-alone optical components such as a camera lens or telescope, and some literature addresses approaches to determine an MTF for combination of an optic with a detector. The formulations pertaining to a combined electro-optical system MTF are mostly based on theory, and assumptions that detector MTF is described only by the pixel pitch which does not account for wavelength dependencies. When working with real hardware, detectors are often characterized by testing MTF at discrete wavelengths. This paper presents a method to simplify the calculation of a polychromatic system MTF when it is permissible to consider the detector MTF to be independent of wavelength.
Huang, Xiaojing; Miao, Huijie; Steinbrener, Jan; ...
2009-01-01
Using a signal-to-noise ratio estimation based on correlations between multiple simulated images, we compare the dose efficiency of two soft x-ray imaging systems: incoherent brightfield imaging using zone plate optics in a transmission x-ray microscope (TXM), and x-ray diffraction microscopy (XDM) where an image is reconstructed from the far-field coherent diffraction pattern. In XDM one must computationally phase weak diffraction signals; in TXM one suffers signal losses due to the finite numerical aperture and efficiency of the optics. In simulations with objects representing isolated cells such as yeast, we find that XDM has the potential for delivering equivalent resolution imagesmore » using fewer photons. As a result, this can be an important advantage for studying radiation-sensitive biological and soft matter specimens.« less
NASA Technical Reports Server (NTRS)
Cash, Webster (Inventor)
2010-01-01
Methods and apparatus are disclosed for occulting light. The occulter shape suppresses diffraction at any given size or angle and is practical to build because it can be made binary to avoid scatter. Binary structures may be fully opaque or fully transmitting at specific points. The diffraction suppression is spectrally broad so that it may be used with incoherent white light. An occulter may also include substantially opaque inner portion and an at least partially transparent outer portion. Such occulters may be used on the ground to create a deep shadow in a short distance, or may be used in space to suppress starlight and reveal exoplanets.
Fukunaga, Masaaki; Onishi, Hideo; Matsutomo, Norikazu; Yamamoto, Hiroyuki
2016-06-01
The purpose of this study was to evaluate the effects of target diameter and display-field of view (D-FOV) in modulation transfer function (MTF) by circular edge strategy using the computed tomography (CT) image measurement program "CTmeasure". We calculated the MTF (MTF(edge)) using the circular edge strategy applied to cylindrical phantom (200 mmφ) that inserted with cylinders have 10, 20, 30, and 40 mm diameters. The phantom images were reconstructed using filtered back projection method varied with D-FOV (240, 320, 400, and 500 mm). The study compared both MTF(edge) and MTF(wire) at MTF50% and MTF(10%) for target diameter and D-FOV, respectively. The MTF(edge) by the different of target diameter indicated in rough compatibility. However, MTF(edge) of D-FOV diameters (320, 400, and 500 mm) decreased in the high frequency range. The circular edge strategy for MTF depended on the D-FOV, however, it was little dependent on target diameter using the CT image measurement program "CTmeasure".
[Drugs for attention deficit hyperactivity disorder].
Montañés-Rada, F; Gangoso-Fermoso, A B; Martíínez-Granero, M A
Quantitative studies have highlighted differences in several drugs approved for use in Spain in the treatment of attention deficit hyperactivity disorder. No clear differences are observed, however, in the case of qualitative studies. The number of patients needed to be treated in order for one to reach complete remission (NNT) of methylphenidate (MTF) is from 2.2 to 5, and the effect size (ES) is 0.9. Atomoxetine has an NNT of 4 and an ES of 0.7. The advantages of immediate-release MTF (IR-MTF) over the extended-release version (ER-MTF) lie in its low cost, its flexibility and the better results obtained in quantitative studies. In contrast, ER-MTF offers a lower risk of abuse, needs to be taken fewer times with less need for third parties to control administration, and there is a lower risk of stigmatisation. Combination or changes of IR-MTF and ER-MTF and the combination of MTF with atomoxetine are sometimes necessary to adjust the weekday or weekend doses. Starting treatment with IR-MTF and then maintaining or changing to ER-MTF offers certain advantages as regards safety, dose adjustments and dosage. Atomoxetine is the best alternative if there is a background of adverse events with low or moderate doses of stimulants, or lack of response to high doses of stimulants. In cases of notable comorbid anxiety, both MTF and atomoxetine have the same level of indication. If there is a risk of substance abuse, both atomoxetine and ER-MTF are the preferred treatment. For the other indications, MTF is the preferred treatment.
Huang, Xiaojing; Lauer, Kenneth; Clark, Jesse N.; ...
2015-03-13
We report an experimental ptychography measurement performed in fly-scan mode. With a visible-light laser source, we demonstrate a 5-fold reduction of data acquisition time. By including multiple mutually incoherent modes into the incident illumination, high quality images were successfully reconstructed from blurry diffraction patterns. Thus, this approach significantly increases the throughput of ptychography, especially for three-dimensional applications and the visualization of dynamic systems.
Heuchel, R; Radtke, F; Georgiev, O; Stark, G; Aguet, M; Schaffner, W
1994-06-15
We have described and cloned previously a factor (MTF-1) that binds specifically to heavy metal-responsive DNA sequence elements in the enhancer/promoter region of metallothionein genes. MTF-1 is a protein of 72.5 kDa that contains six zinc fingers and multiple domains for transcriptional activation. Here we report the disruption of both alleles of the MTF-1 gene in mouse embryonic stem cells by homologous recombination. The resulting null mutant cell line fails to produce detectable amounts of MTF-1. Moreover, due to the loss of MTF-1, the endogenous metallothionein I and II genes are silent, indicating that MTF-1 is required for both their basal and zinc-induced transcription. In addition to zinc, other heavy metals, including cadmium, copper, nickel and lead, also fail to activate metal-responsive promoters in null mutant cells. However, cotransfection of an MTF-1 expression vector and metal-responsive reporter genes yields strong basal transcription that can be further boosted by zinc treatment of cells. These results demonstrate that MTF-1 is essential for metallothionein gene regulation. Finally, we present evidence that MTF-1 itself is a zinc sensor, which exhibits increased DNA binding activity upon zinc treatment.
On-Orbit MTF Measurement and Product Quality Monitoring for Commercial Remote Sensing Systems
NASA Technical Reports Server (NTRS)
Person, Steven
2007-01-01
Initialization and opportunistic targets are chosen that represent the MTF on the spatial domain. Ideal targets have simple mathematical relationships. Determine the MTF of an on-orbit satellite using in-scene targets: Slant-Edge, Line Source, point Source, and Radial Target. Attempt to facilitate the MTF calculation by automatically locating targets of opportunity. Incorporate MTF results into a product quality monitoring architecture.
Ophus, Colin; Ercius, Peter; Huijben, Mark; ...
2017-02-08
The local atomic structure of a crystalline sample aligned along a zone axis can be probed with a focused electron probe, which produces a convergent beam electron diffraction pattern. The introduction of high speed direct electron detectors has allowed for experiments that can record a full diffraction pattern image at thousands of probe positions on a sample. By incoherently summing these patterns over crystalline unit cells, we demonstrate in this paper that in addition to crystal structure and thickness, we can also estimate the local composition of a perovskite superlattice sample. This is achieved by matching the summed patterns tomore » a library of simulated diffraction patterns. Finally, this technique allows for atomic-scale chemical measurements without requiring a spectrometer or hardware aberration correction.« less
O'Shields, Britton; McArthur, Andrew G; Holowiecki, Andrew; Kamper, Martin; Tapley, Jeffrey; Jenny, Matthew J
2014-09-01
The metal responsive element-binding transcription factor-1 (MTF-1) responds to changes in cellular zinc levels caused by zinc exposure or disruption of endogenous zinc homeostasis by heavy metals or oxygen-related stress. Here we report the functional characterization of a complete zebrafish MTF-1 in comparison with the previously identified isoform lacking the highly conserved cysteine-rich motif (Cys-X-Cys-Cys-X-Cys) found in all other vertebrate MTF-1 orthologs. In an effort to develop novel molecular tools, a constitutively nuclear dominant-negative MTF-1 (dnMTF-1) was generated as tool for inhibiting endogenous MTF-1 signaling. The in vivo efficacy of the dnMTF-1 was determined by microinjecting in vitro transcribed dnMTF-1 mRNA into zebrafish embryos (1-2 cell stage) followed by transcriptomic profiling using an Agilent 4x44K array on 28- and 36-hpf embryos. A total of 594 and 560 probes were identified as differentially expressed at 28hpf and 36hpf, respectively, with interesting overlaps between timepoints. The main categories of genes affected by the inhibition of MTF-1 signaling were: nuclear receptors and genes involved in stress signaling, neurogenesis, muscle development and contraction, eye development, and metal homeostasis, including novel observations in iron and heme homeostasis. Finally, we investigate both the transcriptional activator and transcriptional repressor role of MTF-1 in potential novel target genes identified by transcriptomic profiling during early zebrafish development. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Schuster, J.
2018-02-01
Military requirements demand both single and dual-color infrared (IR) imaging systems with both high resolution and sharp contrast. To quantify the performance of these imaging systems, a key measure of performance, the modulation transfer function (MTF), describes how well an optical system reproduces an objects contrast in the image plane at different spatial frequencies. At the center of an IR imaging system is the focal plane array (FPA). IR FPAs are hybrid structures consisting of a semiconductor detector pixel array, typically fabricated from HgCdTe, InGaAs or III-V superlattice materials, hybridized with heat/pressure to a silicon read-out integrated circuit (ROIC) with indium bumps on each pixel providing the mechanical and electrical connection. Due to the growing sophistication of the pixel arrays in these FPAs, sophisticated modeling techniques are required to predict, understand, and benchmark the pixel array MTF that contributes to the total imaging system MTF. To model the pixel array MTF, computationally exhaustive 2D and 3D numerical simulation approaches are required to correctly account for complex architectures and effects such as lateral diffusion from the pixel corners. It is paramount to accurately model the lateral di_usion (pixel crosstalk) as it can become the dominant mechanism limiting the detector MTF if not properly mitigated. Once the detector MTF has been simulated, it is directly decomposed into its constituent contributions to reveal exactly what is limiting the total detector MTF, providing a path for optimization. An overview of the MTF will be given and the simulation approach will be discussed in detail, along with how different simulation parameters effect the MTF calculation. Finally, MTF optimization strategies (crosstalk mitigation) will be discussed.
Ramamoorthy, Vellaisamy; Dhingra, Sourabh; Kincaid, Alexander; Shantappa, Sourabha; Feng, Xuehuan; Calvo, Ana M.
2013-01-01
Secondary metabolism in the model fungus Aspergillus nidulans is controlled by the conserved global regulator VeA, which also governs morphological differentiation. Among the secondary metabolites regulated by VeA is the mycotoxin sterigmatocystin (ST). The presence of VeA is necessary for the biosynthesis of this carcinogenic compound. We identified a revertant mutant able to synthesize ST intermediates in the absence of VeA. The point mutation occurred at the coding region of a gene encoding a novel putative C2H2 zinc finger domain transcription factor that we denominated mtfA. The A. nidulans mtfA gene product localizes at nuclei independently of the illumination regime. Deletion of the mtfA gene restores mycotoxin biosynthesis in the absence of veA, but drastically reduced mycotoxin production when mtfA gene expression was altered, by deletion or overexpression, in A. nidulans strains with a veA wild-type allele. Our study revealed that mtfA regulates ST production by affecting the expression of the specific ST gene cluster activator aflR. Importantly, mtfA is also a regulator of other secondary metabolism gene clusters, such as genes responsible for the synthesis of terrequinone and penicillin. As in the case of ST, deletion or overexpression of mtfA was also detrimental for the expression of terrequinone genes. Deletion of mtfA also decreased the expression of the genes in the penicillin gene cluster, reducing penicillin production. However, in this case, over-expression of mtfA enhanced the transcription of penicillin genes, increasing penicillin production more than 5 fold with respect to the control. Importantly, in addition to its effect on secondary metabolism, mtfA also affects asexual and sexual development in A. nidulans. Deletion of mtfA results in a reduction of conidiation and sexual stage. We found mtfA putative orthologs conserved in other fungal species. PMID:24066102
Optical analysis of electro-optical systems by MTF calculus
NASA Astrophysics Data System (ADS)
Barbarini, Elisa Signoreto; Dos Santos, Daniel, Jr.; Stefani, Mário Antonio; Yasuoka, Fátima Maria Mitsue; Castro Neto, Jarbas C.; Rodrigues, Evandro Luís Linhari
2011-08-01
One of the widely used methods for performance analysis of an optical system is the determination of the Modulation Transfer Function (MTF). The MTF represents a quantitative and direct measure of image quality, and, besides being an objective test, it can be used on concatenated optical system. This paper presents the application of software called SMTF (software modulation transfer function), built in C++ and Open CV platforms for MTF calculation on electro-optical system. Through this technique, it is possible to develop specific method to measure the real time performance of a digital fundus camera, an infrared sensor and an ophthalmological surgery microscope. Each optical instrument mentioned has a particular device to measure the MTF response, which is being developed. Then the MTF information assists the analysis of the optical system alignment, and also defines its resolution limit by the MTF graphic. The result obtained from the implemented software is compared with the theoretical MTF curve from the analyzed systems.
Scattering properties of electromagnetic waves from metal object in the lower terahertz region
NASA Astrophysics Data System (ADS)
Chen, Gang; Dang, H. X.; Hu, T. Y.; Su, Xiang; Lv, R. C.; Li, Hao; Tan, X. M.; Cui, T. J.
2018-01-01
An efficient hybrid algorithm is proposed to analyze the electromagnetic scattering properties of metal objects in the lower terahertz (THz) frequency. The metal object can be viewed as perfectly electrical conducting object with a slightly rough surface in the lower THz region. Hence the THz scattered field from metal object can be divided into coherent and incoherent parts. The physical optics and truncated-wedge incremental-length diffraction coefficients methods are combined to compute the coherent part; while the small perturbation method is used for the incoherent part. With the MonteCarlo method, the radar cross section of the rough metal surface is computed by the multilevel fast multipole algorithm and the proposed hybrid algorithm, respectively. The numerical results show that the proposed algorithm has good accuracy to simulate the scattering properties rapidly in the lower THz region.
Modulation transfer function of a triangular pixel array detector.
Karimzadeh, Ayatollah
2014-07-01
The modulation transfer function (MTF) is the main parameter that is used to evaluate image quality in electro-optical systems. Detector sampling MTF in most electro-optical systems determines the cutoff frequency of the system. The MTF of the detector depends on its pixel shape. In this work, we calculated the MTF of a detector with an equilateral triangular pixel shape. Some new results were found in deriving the MTF for the equilateral triangular pixel shape.
Optimization of x-ray capillary optics for mammography
NASA Astrophysics Data System (ADS)
Ross, Richard E.; Bradford, Carla D.; Peppler, Walter W.
2002-05-01
The purpose of this study is to develop a full-field digital mammography system utilizing capillary optics. Specific aims are to identify optic properties that affect image quality and to optimize those properties in the design of a multi-element capillary array. It has been shown that polycapillary optics significantly improve mammographic image quality through increased resolution and reduced x-ray scatter. For practical clinical application much larger multi-element optics will be required. This study quantified the contributing factors to the multi-element optic MTF and investigated methods to determine optimal parameters for a practical design. Individual and a prototype multi-element array of linearly tapered optics with a common focal point were investigated. A conventional (MO/MO) mammography tube and computed radiography system were used. The system and optic MTF were measured using the angled slit method with a slit camera (10 micron slit). MTF measurements were performed with both stationary and scanned optics. Contributions to MTF included: distortion within individual optics, misalignment between optics, capillary channel size, and vibration. Measurement techniques used to identify and quantify the contributions to optic MTF included a phantom chosen specifically for polycapillary optics. This phantom provided a method for assessing the coherence among capillaries within an optic as well as the relative alignment of the optics within the array. In addition, modifications to the scanning procedure allowed for the isolation and quantification of several contributors to the system MTF. Specifically, measurements were made using a stationary optic, a scanning optic, and an optic placed at multiple locations within the imaged field of view. These techniques yielded the optic MTF, the degradation of MTF due to loss of coherence within the optic, and the degradation of MTF due to vibration of the scanning mechanism. Distortion within individual optics was, typically, quite small. However, MTF degradation resulting from twist was significant in some optics. MTF degradation due to misalignment was relatively large in the prototype triad. Modeling found that misalignment up to 50 microns reduced MTF by less than 10 percent up to 3 cycles/mm. Channel diameters of 52 microns and 85 microns reduced MTF by 9 percent to 20 percent at 5 cycles/mm and provided an optimal tradeoff between transmission and MTF. Vibration was identified as a significant degradation to MTF but can easily reduced with simple modifications. In spite of some reduced optic MTF values, system MTF has always been significantly improved - in some cases almost by the magnification ratio. These results allow for accurate modeling of optic performance and optimization of design parameters. This study demonstrates that a multi-element array can be produced with nearly optimal properties. A large area array suitable for clinical trial is feasible and is the next step in this program.
NASA Technical Reports Server (NTRS)
Anderson, Richard
1994-01-01
The concept in the initial alignment of the segmented mirror adaptive optics telescope called the phased array mirror extendable large aperture telescope (Pamela) is to produce an optical transfer function (OTF) which closely approximates the diffraction limited value which would correspond to a system pupil function that is unity over the aperture and zero outside. There are differences in the theory of intensity measurements between coherent and incoherent radiation. As a result, some of the classical quantities which describe the performance of an optical system for incoherent radiation can not be defined for a coherent field. The most important quantity describing the quality of an optical system is the OTF and for a coherent source the OTF is not defined. Instead a coherent transfer function (CTF) is defined. The main conclusion of the paper is that an incoherent collimated source and not a collimated laser source is preferred to calibrate the Hartmann wavefront sensor (WFS) of an aligned adaptive optical system. A distant laser source can be used with minimum problems to correct the system for atmospheric turbulence. The collimation of the HeNe laser alignment source can be improved by using a very small pin hole in the spatial filter so only the central portion of the beam is transmitted and the beam from the filter is nearly constant in amplitude. The size of this pin hole will be limited by the sensitivity of the lateral effect diode (LEDD) elements.
MTF measurements on real time for performance analysis of electro-optical systems
NASA Astrophysics Data System (ADS)
Stuchi, Jose Augusto; Signoreto Barbarini, Elisa; Vieira, Flavio Pascoal; dos Santos, Daniel, Jr.; Stefani, Mário Antonio; Yasuoka, Fatima Maria Mitsue; Castro Neto, Jarbas C.; Linhari Rodrigues, Evandro Luis
2012-06-01
The need of methods and tools that assist in determining the performance of optical systems is actually increasing. One of the most used methods to perform analysis of optical systems is to measure the Modulation Transfer Function (MTF). The MTF represents a direct and quantitative verification of the image quality. This paper presents the implementation of the software, in order to calculate the MTF of electro-optical systems. The software was used for calculating the MTF of Digital Fundus Camera, Thermal Imager and Ophthalmologic Surgery Microscope. The MTF information aids the analysis of alignment and measurement of optical quality, and also defines the limit resolution of optical systems. The results obtained with the Fundus Camera and Thermal Imager was compared with the theoretical values. For the Microscope, the results were compared with MTF measured of Microscope Zeiss model, which is the quality standard of ophthalmological microscope.
Design of tracking and detecting lens system by diffractive optical method
NASA Astrophysics Data System (ADS)
Yang, Jiang; Qi, Bo; Ren, Ge; Zhou, Jianwei
2016-10-01
Many target-tracking applications require an optical system to acquire the target for tracking and identification. This paper describes a new detecting optical system that can provide automatic flying object detecting, tracking and measuring in visible band. The main feature of the detecting lens system is the combination of diffractive optics with traditional lens design by a technique was invented by Schupmann. Diffractive lens has great potential for developing the larger aperture and lightweight lens. First, the optical system scheme was described. Then the Schupmann achromatic principle with diffractive lens and corrective optics is introduced. According to the technical features and requirements of the optical imaging system for detecting and tracking, we designed a lens system with flat surface Fresnel lens and cancels the optical system chromatic aberration by another flat surface Fresnel lens with effective focal length of 1980mm, an F-Number of F/9.9 and a field of view of 2ωω = 14.2', spatial resolution of 46 lp/mm and a working wavelength range of 0.6 0.85um. At last, the system is compact and easy to fabricate and assembly, the diffuse spot size and MTF function and other analysis provide good performance.
Mid-frequency MTF compensation of optical sparse aperture system.
Zhou, Chenghao; Wang, Zhile
2018-03-19
Optical sparse aperture (OSA) can greatly improve the spatial resolution of optical system. However, because of its aperture dispersion and sparse, its mid-frequency modulation transfer function (MTF) are significantly lower than that of a single aperture system. The main focus of this paper is on the mid-frequency MTF compensation of the optical sparse aperture system. Firstly, the principle of the mid-frequency MTF decreasing and missing of optical sparse aperture are analyzed. This paper takes the filling factor as a clue. The method of processing the mid-frequency MTF decreasing with large filling factor and method of compensation mid-frequency MTF with small filling factor are given respectively. For the MTF mid-frequency decreasing, the image spatial-variant restoration method is proposed to restore the mid-frequency information in the image; for the mid-frequency MTF missing, two images obtained by two system respectively are fused to compensate the mid-frequency information in optical sparse aperture image. The feasibility of the two method are analyzed in this paper. The numerical simulation of the system and algorithm of the two cases are presented using Zemax and Matlab. The results demonstrate that by these two methods the mid-frequency MTF of OSA system can be compensated effectively.
Development of Pseudorandom Binary Arrays for Calibration of Surface Profile Metrology Tools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barber, S.K.; Takacs, P.; Soldate, P.
2009-12-01
Optical metrology tools, especially for short wavelengths (extreme ultraviolet and x-ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown point-spread function (PSF) of the instruments [G. D. Boreman, Modulation Transfer Function in Optical and Electro-Optical Systems (SPIE, Bellingham, WA, 2001)] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account for because the PSF ismore » a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in the spatial frequency domain as a power spectral density (PSD) distribution [J. W. Goodman, Introduction to Fourier Optics, 3rd ed. (Roberts and Company, Englewood, CO, 2005)]. For example, measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [E. L. Church et al., Opt. Eng. (Bellingham) 18, 125 (1979); J. C. Stover, Optical Scattering, 2nd ed. (SPIE Optical Engineering Press, Bellingham, WA, 1995)]. The distortion of the surface PSD distribution due to the PSF can be modeled with the modulation transfer function (MTF), which is defined over the spatial frequency bandwidth of the instrument. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the system under test. Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. The applicability of the MTF concept to phase map measurements with optical interferometric microscopes needs to be experimentally verified as the optical tool and algorithms may introduce nonlinear artifacts into the process. In previous work [V. V. Yashchuk et al., Proc. SPIE 6704, 670408 (2007); Valeriy V. Yashchuk et al., Opt. Eng. (Bellingham) 47, 073602 (2008)] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudorandom (BPR) gratings. Here, the authors present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as global position systems and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the uniformly redundant array (URA) prescription [E. E. Fenimore and T. M. Cannon, Appl. Opt. 17, 337 (1978)] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and induction coupled plasma etching of silicon. The basic size units were 200, 400, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The MicroMap{trademark}-570 interferometric microscope uses incoherent illumination from a tungsten filament source and common path modulated phase shifting interference to produce a set of interferograms detected on a change coupled device. Mathematical algorithms applied to the datasets yield the surface phase map. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples [Samuel K. Barber et al., Abstract to Optics and Photonics 2009: Optical Engineering and Applications Symposium, San Diego, CA, 2-6 August 2009]. Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.« less
NASA Astrophysics Data System (ADS)
Bardoux, Alain; Gimenez, Thierry; Jamin, Nicolas; Seve, Frederic
2017-11-01
MTF (Modulation Transfer Frequency) of a detector is a key parameter for imagers. When image is not moving on the detector, MTF can be measured by some methods (knife edge, slanted slit,…). But with LEO satellites, image is moving on the surface of the detector, and MTF has to be measured in the same way: that is what we call "dynamic MTF". CNES (French Space Agency) has built a specific bench in order to measure dynamic MTF of detectors (CCD and CMOS), especially with component working in TDI (Time delay and integration) mode. The method is based on a moving edge, synchronized with the movement of charges inside the TDI detector. The moving part is a rotating cube, allowing a very stable movement of the image on the surface of the detector The main difficulties were: - stability of the rotating speed - synchronization between cube speed and charge transfer inside the detectors - synchronization between cube position and data acquisition. Different methods have been tested for the displacement of the knife edge: - geometrical displacement - electrical shift of the charge transfer clocks. Static MTF has been performed before dynamic measurements, in order to fix a reference measurement, Then dynamic MTF bench has been set up. The results, for a TDI CCD show a very good precision. So this bench is validated, and the dynamic MTF value of the TDI CCD is confirmed.
32 CFR 728.34 - Care beyond the capabilities of a naval MTF.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 5 2010-07-01 2010-07-01 false Care beyond the capabilities of a naval MTF. 728... Dependents of the Uniformed Services § 728.34 Care beyond the capabilities of a naval MTF. When either during... determination is made that required care or services are beyond the capability of the naval MTF, the provisions...
32 CFR 728.34 - Care beyond the capabilities of a naval MTF.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 32 National Defense 5 2011-07-01 2011-07-01 false Care beyond the capabilities of a naval MTF. 728... Dependents of the Uniformed Services § 728.34 Care beyond the capabilities of a naval MTF. When either during... determination is made that required care or services are beyond the capability of the naval MTF, the provisions...
GOCI image enhancement using an MTF compensation technique for coastal water applications.
Oh, Eunsong; Choi, Jong-Kuk
2014-11-03
The Geostationary Ocean Color Imager (GOCI) is the first optical sensor in geostationary orbit for monitoring the ocean environment around the Korean Peninsula. This paper discusses on-orbit modulation transfer function (MTF) estimation with the pulse-source method and its compensation results for the GOCI. Additionally, by analyzing the relationship between the MTF compensation effect and the accuracy of the secondary ocean product, we confirmed the optimal MTF compensation parameter for enhancing image quality without variation in the accuracy. In this study, MTF assessment was performed using a natural target because the GOCI system has a spatial resolution of 500 m. For MTF compensation with the Wiener filter, we fitted a point spread function with a Gaussian curve controlled by a standard deviation value (σ). After a parametric analysis for finding the optimal degradation model, the σ value of 0.4 was determined to be an optimal indicator. Finally, the MTF value was enhanced from 0.1645 to 0.2152 without degradation of the accuracy of the ocean color product. Enhanced GOCI images by MTF compensation are expected to recognize small-scale ocean products in coastal areas with sharpened geometric performance.
Aerosol scattering and absorption modulation transfer function
NASA Astrophysics Data System (ADS)
Sadot, Dan; Kopeika, Norman S.
1993-08-01
Recent experimental measurements of overall atmospheric modulation transfer function (MTF) indicate significant difference between the turbulence and overall atmospheric MTFs, except often at midday when turbulence is strong. We suggest here a physical explanation for those results which essentially relates to what we call a practical instrumentation-based atmospheric aerosol MTF which is a modification of the classical aerosol MTF theory. It is shown that system field-of-view and dynamic range affect strongly aerosol and overall atmospheric MTFs. It is often necessary to choose between MTF and SNR depending upon dynamic range requirements. Also, a new approach regarding aerosol absorption is presented. It is shown that aerosol-absorbed irradiance is spatial frequency dependent and enhances the degradation in image quality arising from received scattered light. This is most relevant for thermal imaging. An analytically corrected model for the aerosol MTF is presented which is relevant for imaging. An important conclusion is that the aerosol MTF is often the dominant part in the actual overall atmospheric MTF all across the optical spectral region.
MTF measurement and analysis of linear array HgCdTe infrared detectors
NASA Astrophysics Data System (ADS)
Zhang, Tong; Lin, Chun; Chen, Honglei; Sun, Changhong; Lin, Jiamu; Wang, Xi
2018-01-01
The slanted-edge technique is the main method for measurement detectors MTF, however this method is commonly used on planar array detectors. In this paper the authors present a modified slanted-edge method to measure the MTF of linear array HgCdTe detectors. Crosstalk is one of the major factors that degrade the MTF value of such an infrared detector. This paper presents an ion implantation guard-ring structure which was designed to effectively absorb photo-carriers that may laterally defuse between adjacent pixels thereby suppressing crosstalk. Measurement and analysis of the MTF of the linear array detectors with and without a guard-ring were carried out. The experimental results indicated that the ion implantation guard-ring structure effectively suppresses crosstalk and increases MTF value.
Crossover And MTF Characteristics Of A Tabular-Grain X-Ray Film
NASA Astrophysics Data System (ADS)
Huff, K. E.; Wagner, P. W.
1984-08-01
An orthochromatic x-ray film made with tabular silver halide grains has a significantly higher MTF when exposed with green-emitting intensifying screens than do conventional films with similar sensitometric properties. The primary reason for the improved MTF is a decrease in the amount of crossover exposure, i.e., exposure by light that has crossed the support one or more times. Two well-established sensitometric procedures for measuring crossover have been compared. One produces results accurate enough for calculations of MTF relationships. Calculated MTF relationships for tabulargrain and conventional films are compared with measured values.
Modulation Transfer Function (MTF) measurement techniques for lenses and linear detector arrays
NASA Technical Reports Server (NTRS)
Schnabel, J. J., Jr.; Kaishoven, J. E., Jr.; Tom, D.
1984-01-01
Application is the determination of the Modulation Transfer Function (MTF) for linear detector arrays. A system set up requires knowledge of the MTF of the imaging lens. Procedure for this measurement is described for standard optical lab equipment. Given this information, various possible approaches to MTF measurement for linear arrays is described. The knife edge method is then described in detail.
Correlation between k-space sampling pattern and MTF in compressed sensing MRSI.
Heikal, A A; Wachowicz, K; Fallone, B G
2016-10-01
To investigate the relationship between the k-space sampling patterns used for compressed sensing MR spectroscopic imaging (CS-MRSI) and the modulation transfer function (MTF) of the metabolite maps. This relationship may allow the desired frequency content of the metabolite maps to be quantitatively tailored when designing an undersampling pattern. Simulations of a phantom were used to calculate the MTF of Nyquist sampled (NS) 32 × 32 MRSI, and four-times undersampled CS-MRSI reconstructions. The dependence of the CS-MTF on the k-space sampling pattern was evaluated for three sets of k-space sampling patterns generated using different probability distribution functions (PDFs). CS-MTFs were also evaluated for three more sets of patterns generated using a modified algorithm where the sampling ratios are constrained to adhere to PDFs. Strong visual correlation as well as high R 2 was found between the MTF of CS-MRSI and the product of the frequency-dependant sampling ratio and the NS 32 × 32 MTF. Also, PDF-constrained sampling patterns led to higher reproducibility of the CS-MTF, and stronger correlations to the above-mentioned product. The relationship established in this work provides the user with a theoretical solution for the MTF of CS MRSI that is both predictable and customizable to the user's needs.
NASA Astrophysics Data System (ADS)
Shabani, H.; Doblas, A.; Saavedra, G.; Preza, C.
2018-02-01
Three-dimensional (3D) structured illumination (SI) patterns that include lateral and axial variations have attracted more attention recently as their use in fluorescence microscope enhances the 3D resolution of the native imaging system. 3D SI patterns have already been created by interfering three mutually-coherent waves using a diffraction grating or some electro-optical devices such as spatial light modulators. Here, an interesting approach to generate a 3D SI pattern of tunable modulation frequency is shown. Our proposed illumination system is based on the incoherent illumination of a Fresnel biprism using several equidistant linear sources (i.e., slits). Previously, we investigated and compared numerically this tunable SI microscopy (SIM) system with the one achieved with three-wave interference. In this contribution, we implement our proposed incoherent 3D SIM system of tunable-frequency in an open-setup. We evaluate the axial confinement of the illumination pattern obtained with this system by recording the SI pattern using a mirror sample and different number of slits and compare these data with simulation results. Moreover, we verify that with a higher number of slits used, the axial confinement of the pattern increases, and consequently, the system's optical sectioning capability improves.
Directional MTF measurement using sphere phantoms for a digital breast tomosynthesis system
NASA Astrophysics Data System (ADS)
Lee, Changwoo; Baek, Jongduk
2015-03-01
The digital breast tomosynthesis (DBT) has been widely used as a diagnosis imaging modality of breast cancer because of potential for structure noise reduction, better detectability, and less breast compression. Since 3D modulation transfer function (MTF) is one of the quantitative metrics to assess the spatial resolution of medical imaging systems, it is very important to measure 3D MTF of the DBT system to evaluate the resolution performance. In order to do that, Samei et al. used sphere phantoms and applied Thornton's method to the DBT system. However, due to the limitation of Thornton's method, the low frequency drop, caused by the limited data acquisition angle and reconstruction filters, was not measured correctly. To overcome this limitation, we propose a Richardson-Lucy (RL) deconvolution based estimation method to measure the directional MTF. We reconstructed point and sphere objects using FDK algorithm within a 40⁰ data acquisition angle. The ideal 3D MTF is obtained by taking Fourier transform of the reconstructed point object, and three directions (i.e., fx-direction, fy-direction, and fxy-direction) of the ideal 3D MTF are used as a reference. To estimate the directional MTF, the plane integrals of the reconstructed and ideal sphere object were calculated and used to estimate the directional PSF using RL deconvolution technique. Finally, the directional MTF was calculated by taking Fourier transform of the estimated PSF. Compared to the previous method, the proposed method showed a good agreement with the ideal directional MTF, especially at low frequency regions.
Vijayakumar, A; Rosen, Joseph
2017-06-12
Recording digital holograms without wave interference simplifies the optical systems, increases their power efficiency and avoids complicated aligning procedures. We propose and demonstrate a new technique of digital hologram acquisition without two-wave interference. Incoherent light emitted from an object propagates through a random-like coded phase mask and recorded directly without interference by a digital camera. In the training stage of the system, a point spread hologram (PSH) is first recorded by modulating the light diffracted from a point object by the coded phase masks. At least two different masks should be used to record two different intensity distributions at all possible axial locations. The various recorded patterns at every axial location are superposed in the computer to obtain a complex valued PSH library cataloged to its axial location. Following the training stage, an object is placed within the axial boundaries of the PSH library and the light diffracted from the object is once again modulated by the same phase masks. The intensity patterns are recorded and superposed exactly as the PSH to yield a complex hologram of the object. The object information at any particular plane is reconstructed by a cross-correlation between the complex valued hologram and the appropriate element of the PSH library. The characteristics and the performance of the proposed system were compared with an equivalent regular imaging system.
Valdés, Enrique; Sepúlveda-Martínez, Alvaro; Candia, Paula; Abusada, Nancy; Orellana, Rodrigo; Manukian, Bárbara; Cuellar, Eduardo
2018-01-01
We aimed to assess the use of metformin (MTF) in the prevention of gestational diabetes mellitus (GDM) in patients with pregestational insulin resistance (PIR). A double blind, multicenter, randomized trial was carried out in patients with a history of PIR and pregestational MTF treatment. Groups were allocated either to MTF 1700 mg/day or placebo. Patients were recruited between 12 +0 and 15 +6 gestational weeks, and treatment was extended until week 36. A multiple logistic regression analysis was applied to determine the relation between the use of metformin and the development of GDM. One hundred and forty one patients were randomized (68 patients in the MTF group and 73 in the placebo group). A total of 30 patients withdrew from the study during follow-up. Administration of MTF was not associated with a decrease in the incidence of GDM as compared to placebo (37.5% vs 25.4%, respectively; P = 0.2). Moreover, MTF administration was associated with a significant increase in drug intolerance as compared to placebo (14.3% vs 1.8%, respectively; P = 0.02). The use of MTF is not effective in prevention of GDM in populations with PIR. The use of MTF shows a significantly higher frequency of drug intolerance than placebo. © 2017 Japan Society of Obstetrics and Gynecology.
A method to measure the presampling MTF in digital radiography using Wiener deconvolution
NASA Astrophysics Data System (ADS)
Zhou, Zhongxing; Zhu, Qingzhen; Gao, Feng; Zhao, Huijuan; Zhang, Lixin; Li, Guohui
2013-03-01
We developed a novel method for determining the presampling modulation transfer function (MTF) of digital radiography systems from slanted edge images based on Wiener deconvolution. The degraded supersampled edge spread function (ESF) was obtained from simulated slanted edge images with known MTF in the presence of poisson noise, and its corresponding ideal ESF without degration was constructed according to its central edge position. To meet the requirements of the absolute integrable condition of Fourier transformation, the origianl ESFs were mirrored to construct the symmetric pattern of ESFs. Then based on Wiener deconvolution technique, the supersampled line spread function (LSF) could be acquired from the symmetric pattern of degraded supersampled ESFs in the presence of ideal symmetric ESFs and system noise. The MTF is then the normalized magnitude of the Fourier transform of the LSF. The determined MTF showed a strong agreement with the theoritical true MTF when appropriated Wiener parameter was chosen. The effects of Wiener parameter value and the width of square-like wave peak in symmetric ESFs were illustrated and discussed. In conclusion, an accurate and simple method to measure the presampling MTF was established using Wiener deconvolution technique according to slanted edge images.
Modulation transfer function of a fish-eye lens based on the sixth-order wave aberration theory.
Jia, Han; Lu, Lijun; Cao, Yiqing
2018-01-10
A calculation program of the modulation transfer function (MTF) of a fish-eye lens is developed with the autocorrelation method, in which the sixth-order wave aberration theory of ultra-wide-angle optical systems is used to simulate the wave aberration distribution at the exit pupil of the optical systems. The autocorrelation integral is processed with the Gauss-Legendre integral, and the magnification chromatic aberration is discussed to calculate polychromatic MTF. The MTF calculation results of a given example are then compared with those previously obtained based on the fourth-order wave aberration theory of plane-symmetrical optical systems and with those from the Zemax program. The study shows that MTF based on the sixth-order wave aberration theory has satisfactory calculation accuracy even for a fish-eye lens with a large acceptance aperture. And the impacts of different types of aberrations on the MTF of a fish-eye lens are analyzed. Finally, we apply the self-adaptive and normalized real-coded genetic algorithm and the MTF developed in the paper to optimize the Nikon F/2.8 fish-eye lens; consequently, the optimized system shows better MTF performances than those of the original design.
Wang, Yunlong; Ji, Jun; Jiang, Changsong; Huang, Zengyue
2015-04-01
This study was aimed to use the method of modulation transfer function (MTF) to compare image quality among three different Olympus medical rigid cystoscopes in an in vitro model. During the experimental processes, we firstly used three different types of cystoscopes (i. e. OLYMPUS cystourethroscopy with FOV of 12 degrees, OLYMPUS Germany A22003A and OLYMPUS A2013A) to collect raster images at different brightness with industrial camera and computer from the resolution target which is with different spatial frequency, and then we processed the collected images using MALAB software with the optical transfer function MTF to obtain the values of MTF at different brightness and different spatial frequency. We then did data mathematical statistics and compared imaging quality. The statistical data showed that all three MTF values were smaller than 1. MTF values with the spatial frequency gradually increasing would decrease approaching 0 at the same brightness. When the brightness enhanced in the same process at the same spatial frequency, MTF values showed a slowly increasing trend. The three endoscopes' MTF values were completely different. In some cases the MTF values had a large difference, and the maximum difference could reach 0.7. Conclusion can be derived from analysis of experimental data that three Olympus medical rigid cystoscopes have completely different imaging quality abilities. The No. 3 endoscope OLYMPUS A2013A has low resolution but high contrast. The No. 1 endoscope OLYMPUS cystourethroscopy with FOV of 12 degrees, on the contrary, had high resolution and lower contrast. The No. 2 endoscope OLYMPUS Germany A22003A had high contrast and high resolution, and its image quality was the best.
Small pixel cross-talk MTF and its impact on MWIR sensor performance
NASA Astrophysics Data System (ADS)
Goss, Tristan M.; Willers, Cornelius J.
2017-05-01
As pixel sizes reduce in the development of modern High Definition (HD) Mid Wave Infrared (MWIR) detectors the interpixel cross-talk becomes increasingly difficult to regulate. The diffusion lengths required to achieve the quantum efficiency and sensitivity of MWIR detectors are typically longer than the pixel pitch dimension, and the probability of inter-pixel cross-talk increases as the pixel pitch/diffusion length fraction decreases. Inter-pixel cross-talk is most conveniently quantified by the focal plane array sampling Modulation Transfer Function (MTF). Cross-talk MTF will reduce the ideal sinc square pixel MTF that is commonly used when modelling sensor performance. However, cross-talk MTF data is not always readily available from detector suppliers, and since the origins of inter-pixel cross-talk are uniquely device and manufacturing process specific, no generic MTF models appear to satisfy the needs of the sensor designers and analysts. In this paper cross-talk MTF data has been collected from recent publications and the development for a generic cross-talk MTF model to fit this data is investigated. The resulting cross-talk MTF model is then included in a MWIR sensor model and the impact on sensor performance is evaluated in terms of the National Imagery Interoperability Rating Scale's (NIIRS) General Image Quality Equation (GIQE) metric for a range of fnumber/ detector pitch Fλ/d configurations and operating environments. By applying non-linear boost transfer functions in the signal processing chain, the contrast losses due to cross-talk may be compensated for. Boost transfer functions, however, also reduce the signal to noise ratio of the sensor. In this paper boost function limits are investigated and included in the sensor performance assessments.
Measurements of system sharpness for two digital breast tomosynthesis systems
NASA Astrophysics Data System (ADS)
Marshall, N. W.; Bosmans, H.
2012-11-01
The aim of this work was to propose system sharpness parameters for digital breast tomosynthesis (DBT) systems that include the influence of focus size and focus motion for use in quality assurance protocols. X-ray focus size was measured using a multiple pinhole test object, while detector presampling modulation transfer function (MTF) was measured from projection images of a 10 cm × 10 cm, 1 mm thick steel edge, for the Siemens Inspiration and Hologic Selenia Dimensions DBT systems. The height of the edge above the table was then varied from 1 to 78 mm. The MTF expected from theory for the projection images was calculated from the measured detector MTF, focus size MTF and focus motion MTF and was compared against measured curves. Two methods were used to measure the in-plane MTF in the DBT volume: a tungsten wire of diameter 25 µm and an Al edge 0.2 mm thick, both imaged with a 15 mm thick poly(methyl methacrylate) (PMMA) plate. The in-depth point spread function (PSF) was measured using an angled tungsten wire. The full 3D MTF was estimated with a 0.5 mm diameter aluminium bead held in a 45 mm thick PMMA phantom, with the bead 15 and 65 mm above the table. Inspiration DBT projection images are saved at native detector resolution (85 µm), while the Dimensions re-bins projections to 140 µm pixels (2 × 2 binning); both systems used 2 × 2 binning of projection data before reconstruction. The 50% point for the MTF (MTF0.50) measured in the DBT projection images for the tube-travel direction fell as a function of height above the table from 3.60 to 0.90 mm-1 for the Inspiration system and from 2.50 to 1.20 mm-1 for the Dimensions unit. The maximum deviation of measured MTF0.50 from the calculated value was 13%. MTF0.50 measured in-plane (tube-travel direction) fell as a function of height above the table from 1.66 to 0.97 mm-1 for the Inspiration system and from 2.21 to 1.31 mm-1 for the Dimensions system. The full-width half-maximum for the in-depth PSF was 3.0 and 5.9 mm for the Inspiration and Dimensions systems, respectively. There was no difference in the 3D MTF curves, sectioned in the tube-travel direction, for bead heights of 15 and 65 mm above the table. A 25 µm tungsten wire held within a 15 mm thick PMMA plate was found to be a suitable test object for measurement of in-plane MTF. Evaluation of MTF as a function of height above the table, both in the projection images and in the reconstructed planes, provides important information on the impact of focus size and focus motion on the DBT system's imaging performance.
Measurements of system sharpness for two digital breast tomosynthesis systems.
Marshall, N W; Bosmans, H
2012-11-21
The aim of this work was to propose system sharpness parameters for digital breast tomosynthesis (DBT) systems that include the influence of focus size and focus motion for use in quality assurance protocols. X-ray focus size was measured using a multiple pinhole test object, while detector presampling modulation transfer function (MTF) was measured from projection images of a 10 cm × 10 cm, 1 mm thick steel edge, for the Siemens Inspiration and Hologic Selenia Dimensions DBT systems. The height of the edge above the table was then varied from 1 to 78 mm. The MTF expected from theory for the projection images was calculated from the measured detector MTF, focus size MTF and focus motion MTF and was compared against measured curves. Two methods were used to measure the in-plane MTF in the DBT volume: a tungsten wire of diameter 25 µm and an Al edge 0.2 mm thick, both imaged with a 15 mm thick poly(methyl methacrylate) (PMMA) plate. The in-depth point spread function (PSF) was measured using an angled tungsten wire. The full 3D MTF was estimated with a 0.5 mm diameter aluminium bead held in a 45 mm thick PMMA phantom, with the bead 15 and 65 mm above the table. Inspiration DBT projection images are saved at native detector resolution (85 µm), while the Dimensions re-bins projections to 140 µm pixels (2 × 2 binning); both systems used 2 × 2 binning of projection data before reconstruction. The 50% point for the MTF (MTF(0.50)) measured in the DBT projection images for the tube-travel direction fell as a function of height above the table from 3.60 to 0.90 mm(-1) for the Inspiration system and from 2.50 to 1.20 mm(-1) for the Dimensions unit. The maximum deviation of measured MTF(0.50) from the calculated value was 13%. MTF(0.50) measured in-plane (tube-travel direction) fell as a function of height above the table from 1.66 to 0.97 mm(-1) for the Inspiration system and from 2.21 to 1.31 mm(-1) for the Dimensions system. The full-width half-maximum for the in-depth PSF was 3.0 and 5.9 mm for the Inspiration and Dimensions systems, respectively. There was no difference in the 3D MTF curves, sectioned in the tube-travel direction, for bead heights of 15 and 65 mm above the table. A 25 µm tungsten wire held within a 15 mm thick PMMA plate was found to be a suitable test object for measurement of in-plane MTF. Evaluation of MTF as a function of height above the table, both in the projection images and in the reconstructed planes, provides important information on the impact of focus size and focus motion on the DBT system's imaging performance.
Continuous diffraction of molecules and disordered molecular crystals
Yefanov, Oleksandr M.; Ayyer, Kartik; White, Thomas A.; Barty, Anton; Morgan, Andrew; Mariani, Valerio; Oberthuer, Dominik; Pande, Kanupriya
2017-01-01
The intensities of far-field diffraction patterns of orientationally aligned molecules obey Wilson statistics, whether those molecules are in isolation (giving rise to a continuous diffraction pattern) or arranged in a crystal (giving rise to Bragg peaks). Ensembles of molecules in several orientations, but uncorrelated in position, give rise to the incoherent sum of the diffraction from those objects, modifying the statistics in a similar way as crystal twinning modifies the distribution of Bragg intensities. This situation arises in the continuous diffraction of laser-aligned molecules or translationally disordered molecular crystals. This paper develops the analysis of the intensity statistics of such continuous diffraction to obtain parameters such as scaling, beam coherence and the number of contributing independent object orientations. When measured, continuous molecular diffraction is generally weak and accompanied by a background that far exceeds the strength of the signal. Instead of just relying upon the smallest measured intensities or their mean value to guide the subtraction of the background, it is shown how all measured values can be utilized to estimate the background, noise and signal, by employing a modified ‘noisy Wilson’ distribution that explicitly includes the background. Parameters relating to the background and signal quantities can be estimated from the moments of the measured intensities. The analysis method is demonstrated on previously published continuous diffraction data measured from crystals of photosystem II [Ayyer et al. (2016 ▸), Nature, 530, 202–206]. PMID:28808434
Lunar-edge based on-orbit modulation transfer function (MTF) measurement
NASA Astrophysics Data System (ADS)
Cheng, Ying; Yi, Hongwei; Liu, Xinlong
2017-10-01
Modulation transfer function (MTF) is an important parameter for image quality evaluation of on-orbit optical image systems. Various methods have been proposed to determine the MTF of an imaging system which are based on images containing point, pulse and edge features. In this paper, the edge of the moon can be used as a high contrast target to measure on-orbit MTF of image systems based on knife-edge methods. The proposed method is an extension of the ISO 12233 Slanted-edge Spatial Frequency Response test, except that the shape of the edge is a circular arc instead of a straight line. In order to get more accurate edge locations and then obtain a more authentic edge spread function (ESF), we choose circular fitting method based on least square to fit lunar edge in sub-pixel edge detection process. At last, simulation results show that the MTF value at Nyquist frequency calculated using our lunar edge method is reliable and accurate with error less than 2% comparing with theoretical MTF value.
Samei, Ehsan; Buhr, Egbert; Granfors, Paul; Vandenbroucke, Dirk; Wang, Xiaohui
2005-08-07
The modulation transfer function (MTF) is well established as a metric to characterize the resolution performance of a digital radiographic system. Implemented by various laboratories, the edge technique is currently the most widespread approach to measure the MTF. However, there can be differences in the results attributed to differences in the analysis technique employed. The objective of this study was to determine whether comparable results can be obtained from different algorithms processing identical images representative of those of current digital radiographic systems. Five laboratories participated in a round-robin evaluation of six different algorithms including one prescribed in the International Electrotechnical Commission (IEC) 62220-1 standard. The algorithms were applied to two synthetic and 12 real edge images from different digital radiographic systems including CR, and direct- and indirect-conversion detector systems. The results were analysed in terms of variability as well as accuracy of the resulting presampled MTFs. The results indicated that differences between the individual MTFs and the mean MTF were largely below 0.02. In the case of the two simulated edge images, all algorithms yielded similar results within 0.01 of the expected true MTF. The findings indicated that all algorithms tested in this round-robin evaluation, including the IEC-prescribed algorithm, were suitable for accurate MTF determination from edge images, provided the images are not excessively noisy. The agreement of the MTF results was judged sufficient for the measurement of the MTF necessary for the determination of the DQE.
Zhuang, Zhenhong; Lohmar, Jessica M; Satterlee, Timothy; Cary, Jeffrey W; Calvo, Ana M
2016-01-20
Aspergillus flavus produces a variety of toxic secondary metabolites; among them, the aflatoxins (AFs) are the most well known. These compounds are highly mutagenic and carcinogenic, particularly AFB₁. A. flavus is capable of colonizing a number of economically-important crops, such as corn, cotton, peanut and tree nuts, and contaminating them with AFs. Molecular genetic studies in A. flavus could identify novel gene targets for use in strategies to reduce AF contamination and its adverse impact on food and feed supplies worldwide. In the current study, we investigated the role of the master transcription factor gene mtfA in A. flavus. Our results revealed that forced overexpression of mtfA results in a drastic decrease or elimination of several secondary metabolites, among them AFB₁. The reduction in AFB₁ was accompanied by a decrease in aflR expression. Furthermore, mtfA also regulates development; conidiation was influenced differently by this gene depending on the type of colonized substrate. In addition to its effect on conidiation, mtfA is necessary for the normal maturation of sclerotia. Importantly, mtfA positively affects the pathogenicity of A. flavus when colonizing peanut seeds. AF production in colonized seeds was decreased in the deletion mtfA strain and particularly in the overexpression strain, where only trace amounts were detected. Interestingly, a more rapid colonization of the seed tissue occurred when mtfA was overexpressed, coinciding with an increase in lipase activity and faster maceration of the oily part of the seed.
Photonic Materials and Devices for Optical Information Processing and Computing Applications
1991-09-14
Odulov. and X. Soskin. "Diffraction or coupled - aves and ’.-termination of phase mismatch between ho- lographic ;rating and fringe pauter.’ Opt. Acta. vol...linear approximation is most accurate occur for strong levels of av - erage incoherent light illumination I. Two Grating Transcription. When an...Crystal Technology. Inc.. 1060 E. Meadow Circle. Palo Alto. CA 94303 Op-ed. Pnwenrnw and C e.N a0 Coynr C 19" by Acaro : PaSN . Inc. All non of hplrinua amy
Light Diffraction by Large Amplitude Ultrasonic Waves in Liquids
NASA Technical Reports Server (NTRS)
Adler, Laszlo; Cantrell, John H.; Yost, William T.
2016-01-01
Light diffraction from ultrasound, which can be used to investigate nonlinear acoustic phenomena in liquids, is reported for wave amplitudes larger than that typically reported in the literature. Large amplitude waves result in waveform distortion due to the nonlinearity of the medium that generates harmonics and produces asymmetries in the light diffraction pattern. For standing waves with amplitudes above a threshold value, subharmonics are generated in addition to the harmonics and produce additional diffraction orders of the incident light. With increasing drive amplitude above the threshold a cascade of period-doubling subharmonics are generated, terminating in a region characterized by a random, incoherent (chaotic) diffraction pattern. To explain the experimental results a toy model is introduced, which is derived from traveling wave solutions of the nonlinear wave equation corresponding to the fundamental and second harmonic standing waves. The toy model reduces the nonlinear partial differential equation to a mathematically more tractable nonlinear ordinary differential equation. The model predicts the experimentally observed cascade of period-doubling subharmonics terminating in chaos that occurs with increasing drive amplitudes above the threshold value. The calculated threshold amplitude is consistent with the value estimated from the experimental data.
Physics of reflective optics for the soft gamma-ray photon energy range
Fernandez-Perea, Monica; Descalle, Marie -Anne; Soufli, Regina; ...
2013-07-12
Traditional multilayer reflective optics that have been used in the past for imaging at x-ray photon energies as high as 200 keV are governed by classical wave phenomena. However, their behavior at higher energies is unknown, because of the increasing effect of incoherent scattering and the disagreement between experimental and theoretical optical properties of materials in the hard x-ray and gamma-ray regimes. Here, we demonstrate that multilayer reflective optics can operate efficiently and according to classical wave physics up to photon energies of at least 384 keV. We also use particle transport simulations to quantitatively determine that incoherent scattering takesmore » place in the mirrors but it does not affect the performance at the Bragg angles of operation. Furthermore, our results open up new possibilities of reflective optical designs in a spectral range where only diffractive optics (crystals and lenses) and crystal monochromators have been available until now.« less
An initial analysis of short- and medium-range correlations potential non-Pt catalysts in CoNx
NASA Astrophysics Data System (ADS)
Peterson, Joe
2009-10-01
A potential show stopper for the development of fuel cells for the commercial automotive industry is the design of low-cost catalysts. The best catalysts are based on platinum, which is a rare and expensive noble metal. Our group has been involved in the characterization of potential materials for non-Pt catalysts. In this presentation, I will present some preliminary neutron scattering data from a nanocrystalline powder sample of CoNx. It is apparent that the diffraction data cannot be analyzed with standard Riedveld refinement, and we have to invoke pair distribution function (PDF) analysis. The PDF provides insight into short-range correlations, as it measures the probabilities of short- and mid-range interatomic distances in a material. The analysis reveals a strong incoherent scattering response, which is indicative of the presence of hydrogen in the sample. After correcting for the incoherent scattering, one obtains the normalized scattering function S(Q), whose Fourier transform yields the PDF.
An initial analysis of short- and medium-range correlations potential non-Pt catalysts in CoNx
NASA Astrophysics Data System (ADS)
Peterson, Joe
2010-03-01
A potential show stopper for the development of fuel cells for the commercial automotive industry is the design of low-cost catalysts. The best catalysts are based on platinum, which is a rare and expensive noble metal. Our group has been involved in the characterization of potential materials for non-Pt catalysts. In this presentation, I will present some preliminary neutron scattering data from a nanocrystalline powder sample of CoNx. It is apparent that the diffraction data cannot be analyzed with standard Riedveld refinement, and we have to invoke pair distribution function (PDF) analysis. The PDF provides insight into short-range correlations, as it measures the probabilities of short- and mid-range interatomic distances in a material. The analysis reveals a strong incoherent scattering response, which is indicative of the presence of hydrogen in the sample. After correcting for the incoherent scattering, one obtains the normalized scattering function S(Q), whose Fourier transform yields the PDF.
Assessing the Performance of Military Treatment Facilities
2011-01-01
NUMBER OF PAGES 140 19a. NAME OF RESPONSIBLE PERSON a. REPORT unclassified b. ABSTRACT unclassified c . THIS PAGE unclassified Standard Form...Benchmark Analysis of MTF Outcomes . . . . . . . . 73 C . Outpatient utilization and MTF Size...and FY 2006, Mean by MTF Size Quintile . . . . . . . . . . . . . . . . . . . . . 99 C .1. Regression of Outpatient Utilization
Miyajima, Eiichi; Taira, Naoki; Koda, Munenaga; Kondo, Tsuyoshi
2014-12-15
The present study aimed to investigate differences in personality traits among male-to-female (MtF), female-to-male (FtM) gender identity disorder (GID) subjects and non-transsexual male (M) and female (F) controls. Subjects were 72 MtF and 187 FtM GID subjects without psychiatric comorbidities together with 184 male and 159 female non-transsexual controls. Personality traits were assessed using a short version of the Temperament and Character Inventory (TCI-125). Group comparisons were made by two-way ANOVA. Statistical significances were observed as follows: 1) lower novelty seeking in FtM than in M or MtF, 2) higher reward dependence in FtM than in M, 3) higher cooperativeness in FtM than in M or MtF, 4) the highest self-transcendence in MtF among all the groups. The highest self-transcendence in MtF subjects may reflect their vulnerable identity and constrained adaptation to society as the minority. Nevertheless, higher reward dependence and cooperativeness in FtM subjects can be related to more determined motivation for the treatments of GID and might promise better social functioning and adjustment than MtF subjects. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Bok, Jan; Schauer, Petr
2014-01-01
In the paper, the SEM detector is evaluated by the modulation transfer function (MTF) which expresses the detector's influence on the SEM image contrast. This is a novel approach, since the MTF was used previously to describe only the area imaging detectors, or whole imaging systems. The measurement technique and calculation of the MTF for the SEM detector are presented. In addition, the measurement and calculation of the detective quantum efficiency (DQE) as a function of the spatial frequency for the SEM detector are described. In this technique, the time modulated e-beam is used in order to create well-defined input signal for the detector. The MTF and DQE measurements are demonstrated on the Everhart-Thornley scintillation detector. This detector was alternated using the YAG:Ce, YAP:Ce, and CRY18 single-crystal scintillators. The presented MTF and DQE characteristics show good imaging properties of the detectors with the YAP:Ce or CRY18 scintillator, especially for a specific type of the e-beam scan. The results demonstrate the great benefit of the description of SEM detectors using the MTF and DQE. In addition, point-by-point and continual-sweep e-beam scans in SEM were discussed and their influence on the image quality was revealed using the MTF. © 2013 Wiley Periodicals, Inc.
Saini, Nidhi; Georgiev, Oleg; Schaffner, Walter
2011-01-01
The gene for Parkin, an E3 ubiquitin ligase, is mutated in some familial forms of Parkinson's disease, a severe neurodegenerative disorder. A homozygous mutant of the Drosophila ortholog of human parkin is viable but results in severe motoric impairment including an inability to fly, female and male sterility, and a decreased life span. We show here that a double mutant of the genes for Parkin and the metal-responsive transcription factor 1 (MTF-1) is not viable. MTF-1, which is conserved from insects to mammals, is a key regulator of heavy metal homeostasis and detoxification and plays additional roles in other stress conditions, notably oxidative stress. In contrast to the synthetic lethality of the double mutant, elevated expression of MTF-1 dramatically ameliorates the parkin mutant phenotype, as evidenced by a prolonged life span, motoric improvement including short flight episodes, and female fertility. At the cellular level, muscle and mitochondrial structures are substantially improved. A beneficial effect is also seen with a transgene encoding human MTF-1. We propose that Parkin and MTF-1 provide complementary functions in metal homeostasis, oxidative stress and other cellular stress responses. Our findings also raise the possibility that MTF-1 gene polymorphisms in humans could affect the severity of Parkinson's disease. PMID:21383066
MTF Driven by Plasma Liner Dynamically Formed by the Merging of Plasma Jets: An Overview
NASA Technical Reports Server (NTRS)
Thio, Y. C. Francis; Eskridge, Richard; Martin, Adam; Smith, James; Lee, Michael; Rodgers, Stephen L. (Technical Monitor)
2001-01-01
One approach for standoff delivery of the momentum flux for compressing the target in MTF consists of using a spherical array of plasma jets to form a spherical plasma shell imploding towards the center of a magnetized plasma, a compact toroid (Figure 1). A 3-year experiment (PLX-1) to explore the physics of forming a 2-D plasma liner (shell) by merging plasma jets is described. An overview showing how this 3-year project (PLX-1) fits into the program plan at the national and international level for realizing MTF for energy and propulsion is discussed. Assuming that there will be a parallel program in demonstrating and establishing the underlying physics principles of MTF using whatever liner is appropriate (e.g. a solid liner) with a goal of demonstrating breakeven by 2010, the current research effort at NASA MSFC attempts to complement such a program by addressing the issues of practical embodiment of MTF for propulsion. Successful conclusion of PLX-1 will be followed by a Physics Feasibility Experiment (PLX-2) for the Plasma Liner Driven MTF.
Huard, Edouard; Derelle, Sophie; Jaeck, Julien; Nghiem, Jean; Haïdar, Riad; Primot, Jérôme
2018-03-05
A challenging point in the prediction of the image quality of infrared imaging systems is the evaluation of the detector modulation transfer function (MTF). In this paper, we present a linear method to get a 2D continuous MTF from sparse spectral data. Within the method, an object with a predictable sparse spatial spectrum is imaged by the focal plane array. The sparse data is then treated to return the 2D continuous MTF with the hypothesis that all the pixels have an identical spatial response. The linearity of the treatment is a key point to estimate directly the error bars of the resulting detector MTF. The test bench will be presented along with measurement tests on a 25 μm pitch InGaAs detector.
Cheraghi, Ebrahim; Soleimani Mehranjani, Malek; Shariatzadeh, Mohammad Ali; Nasr Esfahani, Mohammad Hossein; Ebrahimi, Zahra
2014-01-01
Background Studies have demonstrated the efficacy of metformin (MTF ) in reducing insulin resistance and N-acetyl cysteine (NAC) in inhibiting oxidative stress which are involved in the pathogenesis of polycystic ovarian syndrome (PCOS). We aimed to compare the effects of MTF and NAC combination on serum metabolite and hormonal levels during the course of ovulation induction in PCOS individual candidates of intracytoplasmic sperm injection (ICSI). Materials and Methods In this prospective randomized clinical trial, placebo con- trolled pilot study, 80 patients of polycystic ovarian syndrome at the age of 25-35 years were divided into 4 groups (n=20): i. NAC=treated with N-acetyl cysteine (600 mg three times daily), ii. MTF=treated with metformin (500 mg three times daily), iii. MTF+NAC=treated with N-acetyl cysteine plus metformin (the offered doses) and iv. placebo (PLA). A total number of 20 patients (6 from MTF group, 4 from NAC group, 6 from MTF+NAC group and 4 from PLA group) were dropped of the study. The drugs were administrated from day 3 of menses of previous cycle until ovum pick-up. Results Serum levels of luteinizing hormone (LH), total testosterone, cholester- ol and triglyceride, insulin and leptin significantly reduced in the MTF and NAC groups compared to the placebo (p<0.01). But levels of LH, total testosterone, cholesterol and triglyceride had no significant reduction in the MTF+NAC groups compared to the placebo. The serum levels of malonyldialdehyde (MDA), insulin and leptin reduced significantly after treatment in the MTF+NAC group compared to the placebo (p<0.05). Conclusion Considering the adverse effect of combination therapy, we proposed the conadministration might have no beneficial effect for PCOS patient during course of ovulation induction of ICSI (Registration Number: IRCT201204159476N1). PMID:25083175
Anderson-Wurf, Jane; McGirr, Joe; Seal, Alexa; Harding, Catherine
2017-12-01
A study of orthopedic surgeons in rural and regional Southeast Australia to determine attitudes to investigation and management of osteoporosis found they believe follow-up in regard to osteoporosis after MTF is important; responsibility for follow-up diagnosis and management lies with primary health care and current communication systems are poor. The investigation and treatment of osteoporosis after minimal trauma fracture (MTF) is regarded as sub-optimal. There is strong evidence of the benefit of identifying and treating osteoporosis after MTF, and there has been discussion of the possible role that orthopedic surgeons might play in the management of osteoporosis after MTF. The study surveyed orthopedic surgeons in rural and regional Southeast Australia to determine their attitudes to investigation and management of osteoporosis, the role health professionals should play, and the communication and co-ordination of follow-up care. A survey was developed and piloted prior to being posted to 69 orthopedic surgeons asking for their opinions about the general management of osteoporosis, and the roles and responsibilities of health professionals in dealing with osteoporosis following an MTF. Responses were received from 42 participants (60.8%) with the majority of respondents agreeing that it is important to treat osteoporosis following MTF. Less than 15% of respondents felt that it was their responsibility to initiate discussion or treatment or investigation after MTF. No respondent felt that the coordination of osteoporosis care was good and 45% stated it was poor. Communication after discharge is mostly left to the hospital (30%), while 20% stated they did not follow up at all. This study shows that many rural orthopedic surgeons believe that follow-up in regard to osteoporosis after MTF is important, that responsibility for follow-up diagnosis and management of osteoporosis lies with primary health care and the current communication systems are poor.
Wells, Jered R.; Dobbins, James T.
2012-01-01
Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm−1) and approximate circular symmetry at frequencies below 4 mm−1. While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm−1. Slit measurement near 45° revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm × 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm−1) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of 1D test devices for MTF assessment make this a valuable technique for 2D MTF estimation. PMID:23039654
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wells, Jered R.; Dobbins, James T. III; Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705
2012-10-15
Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1Dmore » test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm{sup -1}) and approximate circular symmetry at frequencies below 4 mm{sup -1}. While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm{sup -1}. Slit measurement near 45 Degree-Sign revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm Multiplication-Sign 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm{sup -1}) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of 1D test devices for MTF assessment make this a valuable technique for 2D MTF estimation.« less
Wells, Jered R; Dobbins, James T
2012-10-01
The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ∕i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm(-1)) and approximate circular symmetry at frequencies below 4 mm(-1). While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm(-1). Slit measurement near 45° revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm × 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm(-1)) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Overall, the general availability, acceptance, accuracy, and ease of implementation of 1D test devices for MTF assessment make this a valuable technique for 2D MTF estimation.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-05
... hospitals located within Military Treatment Facility (MTF) Prime Service Areas (PSAs) and deemed essential... costs. It has come to our attention that there may be some CAHs located in MTF PSAs that are deemed... proposing a CAH TMCPA for TRICARE network hospitals located within MTF PSAs and deemed essential for...
Validation of a Custom-made Software for DQE Assessment in Mammography Digital Detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ayala-Dominguez, L.; Perez-Ponce, H.; Brandan, M. E.
2010-12-07
This works presents the validation of a custom-made software, designed and developed in Matlab, intended for routine evaluation of detective quantum efficiency DQE, according to algorithms described in the IEC 62220-1-2 standard. DQE, normalized noise power spectrum NNPS and pre-sampling modulation transfer function MTF were calculated from RAW images from a GE Senographe DS (FineView disabled) and a Siemens Novation system. Calculated MTF is in close agreement with results obtained with alternative codes: MTF lowbar tool (Maidment), ImageJ plug-in (Perez-Ponce) and MIQuaELa (Ayala). Overall agreement better than {approx_equal}90% was found in MTF; the largest differences were observed at frequencies closemore » to the Nyquist limit. For the measurement of NNPS and DQE, agreement is similar to that obtained in the MTF. These results suggest that the developed software can be used with confidence for image quality assessment.« less
Resolution Properties Of A Computed Radiographic System
NASA Astrophysics Data System (ADS)
Fujita, Hiroshi; Morishita, Junji; Ueda, Katsuhiko; Tsai, Du Y.; Ohtsuka, Akiyoshi; Fujikawa, Tsuyoshi
1989-05-01
The analysis of spatial-resolution properties in terms of the modulation transfer function (MTF) has been presented in a computed radiographic (CR) system (FCR-101) with the photostimulable-phosphor plate (imaging plate, IP). The newly devised method of determining the presampling MTF which includes the x-ray detector (IP) unsharpness and the unsharpness of the sampling aperture is described in which an image of a slightly-angulated lead slit relative to a horizontal or vertical direction is employed. The IP MTFs as an analog MTF in the system, the presampling MTFs for different types of IPs, different sampling distances, different versions of IPs, simultaneous multisection tomography and magnification radiography, and the laser-printer MTFs as display MTF are measured and shown. The effective sampling aperture MTFs calculated indicate that the noticeable degradation of resolution occurs at the stage of image data sampling. The usefulness of the magnification technique for mammography and bone radiography is demonstrated. It is shown that both of the digital MTF and the overall MTF are difficult to use for general purpose due to the aliasing artifacts. The effect of glare on the contrast is also characterized by lead-disk method. The glare fraction is found to be approximately 6.5%.
NASA Astrophysics Data System (ADS)
Li, Ke; Zambelli, Joseph; Bevins, Nicholas; Ge, Yongshuai; Chen, Guang-Hong
2013-06-01
By adding a Talbot-Lau interferometer to a conventional x-ray absorption computed tomography (CT) imaging system, both differential phase contrast (DPC) signal and absorption contrast signal can be simultaneously measured from the same set of CT measurements. The imaging performance of such multi-contrast x-ray CT imaging systems can be characterized with standard metrics such as noise variance, noise power spectrum, contrast-to-noise ratio, modulation transfer function (MTF), and task-based detectability index. Among these metrics, the measurement of the MTF can be challenging in DPC-CT systems due to several confounding factors such as phase wrapping and the difficulty of using fine wires as probes. To address these technical challenges, this paper discusses a viable and reliable method to experimentally measure the MTF of DPC-CT. It has been found that the spatial resolution of DPC-CT is degraded, when compared to that of the corresponding absorption CT, due to the presence of a source grating G0 in the Talbot-Lau interferometer. An effective MTF was introduced and experimentally estimated to describe the impact of the Talbot-Lau interferometer on the system MTF.
Addressing challenges of modulation transfer function measurement with fisheye lens cameras
NASA Astrophysics Data System (ADS)
Deegan, Brian M.; Denny, Patrick E.; Zlokolica, Vladimir; Dever, Barry; Russell, Laura
2015-03-01
Modulation transfer function (MTF) is a well defined and accepted method of measuring image sharpness. The slanted edge test, as defined in ISO12233 is a standard method of calculating MTF, and is widely used for lens alignment and auto-focus algorithm verification. However, there are a number of challenges which should be considered when measuring MTF in cameras with fisheye lenses. Due to trade-offs related Petzval curvature, planarity of the optical plane is difficult to achieve in fisheye lenses. It is therefore critical to have the ability to accurately measure sharpness throughout the entire image, particularly for lens alignment. One challenge for fisheye lenses is that, because of the radial distortion, the slanted edges will have different angles, depending on the location within the image and on the distortion profile of the lens. Previous work in the literature indicates that MTF measurements are robust for angles between 2 and 10 degrees. Outside of this range, MTF measurements become unreliable. Also, the slanted edge itself will be curved by the lens distortion, causing further measurement problems. This study summarises the difficulties in the use of MTF for sharpness measurement in fisheye lens cameras, and proposes mitigations and alternative methods.
Hunter, David M; Belev, George; Kasap, Safa; Yaffe, Martin J
2012-02-01
Theoretical reasoning suggests that direct conversion digital x-ray detectors based upon photoconductive amorphous-selenium (a-Se) could attain very high values of the MTF (modulation transfer function) at spatial frequencies well beyond 20 cycles mm(-1). One of the fundamental factors affecting resolution loss, particularly at x-ray energies just above the K-edge of selenium (12.66 keV), is the K-fluorescence reabsorption mechanism, wherein energy can be deposited in the detector at locations laterally displaced from the initial x-ray interaction site. This paper compares measured MTF changes above and below the Se K-edge of a CCD based a-Se x-ray detector with theoretical expectations. A prototype 25 μm sampling pitch (Nyquist frequency = 20 cycles mm(-1), 200 μm thick a-Se layer based x-ray detector, utilizing a specialized CCD readout device (200 × 400 area array), was used to make edge images with monochromatic x-rays above and below the K-edge of Se. A vacuum double crystal monochromator, exposed to polychromatic x-rays from a synchrotron, formed the monochromatic x-ray source. The monochromaticity of the x-rays was 99% or better. The presampling MTF was determined using the slanted edge method. The theory modeling the MTF performance of the detector includes the basic x-ray interaction physics in the a-Se layer as well as effects related to the operation of the CCD and charge trapping at a blocking layer present at the CCD/a-Se interface. The MTF performance of the prototype a-Se CCD was reduced from the theoretical value prescribed by the basic Se x-ray interaction physics, principally by the presence of a blocking layer. Nevertheless, the K-fluorescence reduction in the MTF was observed, approximately as predicted by theory. For the CCD prototype detector, at five cycles mm(-1), there was a 14% reduction of the MTF, from a value of 0.7 below the K-edge of Se, to 0.6 just above the K-edge. The MTF of an a-Se x-ray detector has been measured using monochromatic x-rays above and below the K-edge of selenium. The MTF is poorer above the K-edge by an amount consistent with theoretical expectations.
ERIC Educational Resources Information Center
Dacakis, Georgia; Oates, Jennifer; Douglas, Jacinta
2017-01-01
Background: The Transsexual Voice Questionnaire (TVQ[Superscript MtF]) was designed to capture the voice-related perceptions of individuals whose gender identity as female is the opposite of their birth-assigned gender (MtF women). Evaluation of the psychometric properties of the TVQ[Superscript MtF]is ongoing. Aims: To investigate associations…
A numerical wave-optical approach for the simulation of analyzer-based x-ray imaging
NASA Astrophysics Data System (ADS)
Bravin, A.; Mocella, V.; Coan, P.; Astolfo, A.; Ferrero, C.
2007-04-01
An advanced wave-optical approach for simulating a monochromator-analyzer set-up in Bragg geometry with high accuracy is presented. The polychromaticity of the incident wave on the monochromator is accounted for by using a distribution of incoherent point sources along the surface of the crystal. The resulting diffracted amplitude is modified by the sample and can be well represented by a scalar representation of the optical field where the limitations of the usual ‘weak object’ approximation are removed. The subsequent diffraction mechanism on the analyzer is described by the convolution of the incoming wave with the Green-Riemann function of the analyzer. The free space propagation up to the detector position is well reproduced by a classical Fresnel-Kirchhoff integral. The preliminary results of this innovative approach show an excellent agreement with experimental data.
Single shot multi-wavelength phase retrieval with coherent modulation imaging.
Dong, Xue; Pan, Xingchen; Liu, Cheng; Zhu, Jianqiang
2018-04-15
A single shot multi-wavelength phase retrieval method is proposed by combining common coherent modulation imaging (CMI) and a low rank mixed-state algorithm together. A radiation beam consisting of multi-wavelength is illuminated on the sample to be observed, and the exiting field is incident on a random phase plate to form speckle patterns, which is the incoherent superposition of diffraction patterns of each wavelength. The exiting complex amplitude of the sample including both the modulus and phase of each wavelength can be reconstructed simultaneously from the recorded diffraction intensity using a low rank mixed-state algorithm. The feasibility of this proposed method was verified with visible light experimentally. This proposed method not only makes CMI realizable with partially coherent illumination but also can extend its application to various traditionally unrelated fields, where several wavelengths should be considered simultaneously.
Assessment of a liquid lens enabled in vivo optical coherence microscope.
Murali, Supraja; Meemon, Panomsak; Lee, Kye-Sung; Kuhn, William P; Thompson, Kevin P; Rolland, Jannick P
2010-06-01
The optical aberrations induced by imaging through skin can be predicted using formulas for Seidel aberrations of a plane-parallel plate. Knowledge of these aberrations helps to guide the choice of numerical aperture (NA) of the optics we can use in an implementation of Gabor domain optical coherence microscopy (GD-OCM), where the focus is the only aberration adjustment made through depth. On this basis, a custom-designed, liquid-lens enabled dynamic focusing optical coherence microscope operating at 0.2 NA is analyzed and validated experimentally. As part of the analysis, we show that the full width at half-maximum metric, as a characteristic descriptor for the point spread function, while commonly used, is not a useful metric for quantifying resolution in non-diffraction-limited systems. Modulation transfer function (MTF) measurements quantify that the liquid lens performance is as predicted by design, even when accounting for the effect of gravity. MTF measurements in a skinlike scattering medium also quantify the performance of the microscope in its potential applications. To guide the fusion of images across the various focus positions of the microscope, as required in GD-OCM, we present depth of focus measurements that can be used to determine the effective number of focusing zones required for a given goal resolution. Subcellular resolution in an onion sample, and high-definition in vivo imaging in human skin are demonstrated with the custom-designed and built microscope.
MTF measurement of LCDs by a linear CCD imager: I. Monochrome case
NASA Astrophysics Data System (ADS)
Kim, Tae-hee; Choe, O. S.; Lee, Yun Woo; Cho, Hyun-Mo; Lee, In Won
1997-11-01
We construct the modulation transfer function (MTF) measurement system of a LCD using a linear charge-coupled device (CCD) imager. The MTF used in optical system can not describe in the effect of both resolution and contrast on the image quality of display. Thus we present the new measurement method based on the transmission property of a LCD. While controlling contrast and brightness levels, the MTF is measured. From the result, we show that the method is useful for describing of the image quality. A ne measurement method and its condition are described. To demonstrate validity, the method is applied for comparison of the performance of two different LCDs.
Contrast computation methods for interferometric measurement of sensor modulation transfer function
NASA Astrophysics Data System (ADS)
Battula, Tharun; Georgiev, Todor; Gille, Jennifer; Goma, Sergio
2018-01-01
Accurate measurement of image-sensor frequency response over a wide range of spatial frequencies is very important for analyzing pixel array characteristics, such as modulation transfer function (MTF), crosstalk, and active pixel shape. Such analysis is especially significant in computational photography for the purposes of deconvolution, multi-image superresolution, and improved light-field capture. We use a lensless interferometric setup that produces high-quality fringes for measuring MTF over a wide range of frequencies (here, 37 to 434 line pairs per mm). We discuss the theoretical framework, involving Michelson and Fourier contrast measurement of the MTF, addressing phase alignment problems using a moiré pattern. We solidify the definition of Fourier contrast mathematically and compare it to Michelson contrast. Our interferometric measurement method shows high detail in the MTF, especially at high frequencies (above Nyquist frequency). We are able to estimate active pixel size and pixel pitch from measurements. We compare both simulation and experimental MTF results to a lens-free slanted-edge implementation using commercial software.
Takatsu, Yasuo; Ueyama, Tsuyoshi; Miyati, Tosiaki; Yamamura, Kenichirou
2016-12-01
The image characteristics in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) depend on the partial Fourier fraction and contrast medium concentration. These characteristics were assessed and the modulation transfer function (MTF) was calculated by computer simulation. A digital phantom was created from signal intensity data acquired at different contrast medium concentrations on a breast model. The frequency images [created by fast Fourier transform (FFT)] were divided into 512 parts and rearranged to form a new image. The inverse FFT of this image yielded the MTF. From the reference data, three linear models (low, medium, and high) and three exponential models (slow, medium, and rapid) of the signal intensity were created. Smaller partial Fourier fractions, and higher gradients in the linear models, corresponded to faster MTF decline. The MTF more gradually decreased in the exponential models than in the linear models. The MTF, which reflects the image characteristics in DCE-MRI, was more degraded as the partial Fourier fraction decreased.
Modulation transfer function estimation of optical lens system by adaptive neuro-fuzzy methodology
NASA Astrophysics Data System (ADS)
Petković, Dalibor; Shamshirband, Shahaboddin; Pavlović, Nenad T.; Anuar, Nor Badrul; Kiah, Miss Laiha Mat
2014-07-01
The quantitative assessment of image quality is an important consideration in any type of imaging system. The modulation transfer function (MTF) is a graphical description of the sharpness and contrast of an imaging system or of its individual components. The MTF is also known and spatial frequency response. The MTF curve has different meanings according to the corresponding frequency. The MTF of an optical system specifies the contrast transmitted by the system as a function of image size, and is determined by the inherent optical properties of the system. In this study, the adaptive neuro-fuzzy (ANFIS) estimator is designed and adapted to estimate MTF value of the actual optical system. Neural network in ANFIS adjusts parameters of membership function in the fuzzy logic of the fuzzy inference system. The back propagation learning algorithm is used for training this network. This intelligent estimator is implemented using Matlab/Simulink and the performances are investigated. The simulation results presented in this paper show the effectiveness of the developed method.
[Design and analysis of a novel light visible spectrum imaging spectrograph optical system].
Shen, Man-de; Li, Fei; Zhou, Li-bing; Li, Cheng; Ren, Huan-huan; Jiang, Qing-xiu
2015-02-01
A novel visible spectrum imaging spectrograph optical system was proposed based on the negative dispersion, the arbitrary phase modulation characteristics of diffractive optical element and the aberration correction characteristics of freeform optical element. The double agglutination lens was substituted by a hybrid refractive/diffractive lens based on the negative dispersion of diffractive optical element. Two freeform optical elements were used in order to correct some aberration based on the aberration correction characteristics of freeform optical element. An example and frondose design process were presented. When the design parameters were uniform, compared with the traditional system, the novel visible spectrum imaging spectrograph optical system's weight was reduced by 22.9%, the total length was reduced by 26.6%, the maximal diameter was reduced by 30.6%, and the modulation transfer function (MTF) in 1.0 field-of-view was improved by 0.35 with field-of-view improved maximally. The maximal distortion was reduced by 1.6%, the maximal longitudinal aberration was reduced by 56.4%, and the lateral color aberration was reduced by 59. 3%. From these data, we know that the performance of the novel system was advanced quickly and it could be used to put forward a new idea for modern visible spectrum imaging spectrograph optical system design.
MTF analysis using lunar observations for Himawari-8/AHI
NASA Astrophysics Data System (ADS)
Keller, Graziela R.; Chang, Tiejun; Xiong, Xiaoxiong
2017-09-01
The modulation transfer function, or MTF, is a common measure of image fidelity, which has been historically characterized on-orbit using high contrast images of the lunar limb obtained by remote sensing instruments onboard both low-orbit and geostationary satellites. Himawari-8, launched in 2014, is a Japanese geostationary satellite that carries the Advanced Himawari Imager (AHI), a near-identical copy of the Advanced Baseline Imager (ABI) instrument onboard the GOES-16 satellite. In this paper, we apply a variation of the slantededge method for deriving the MTF from lunar images, first verified by us on simulated test images, to the Himawari-8/AHI L1A and L1B data. The MTF is derived along the North/South and East/West directions separately. The AHI L1A images used in the characterization of the MTF are obtained from lunar observations routinely acquired for validating the radiometric calibration. The L1B data, which is spatially re-sampled, come from serendipitous lunar observations where the Moon appears close to the Earth's disk. We developed and implemented an algorithm to identify such occurrences using the SPICE/Icy package to predict the times where the Moon is visible in the L1B imagery and demonstrate their use for MTF derivation.
The effect of split pixel HDR image sensor technology on MTF measurements
NASA Astrophysics Data System (ADS)
Deegan, Brian M.
2014-03-01
Split-pixel HDR sensor technology is particularly advantageous in automotive applications, because the images are captured simultaneously rather than sequentially, thereby reducing motion blur. However, split pixel technology introduces artifacts in MTF measurement. To achieve a HDR image, raw images are captured from both large and small sub-pixels, and combined to make the HDR output. In some cases, a large sub-pixel is used for long exposure captures, and a small sub-pixel for short exposures, to extend the dynamic range. The relative size of the photosensitive area of the pixel (fill factor) plays a very significant role in the output MTF measurement. Given an identical scene, the MTF will be significantly different, depending on whether you use the large or small sub-pixels i.e. a smaller fill factor (e.g. in the short exposure sub-pixel) will result in higher MTF scores, but significantly greater aliasing. Simulations of split-pixel sensors revealed that, when raw images from both sub-pixels are combined, there is a significant difference in rising edge (i.e. black-to-white transition) and falling edge (white-to-black) reproduction. Experimental results showed a difference of ~50% in measured MTF50 between the falling and rising edges of a slanted edge test chart.
Robinson, Nicole; Kavanagh, David; Connor, Jason; May, Jon; Andrade, Jackie
2016-08-01
The Elaborated Intrusion Theory of Desire holds that desires for functional and dysfunctional goals share a common form. Both are embodied cognitive events, characterised by affective intensity and frequency. Accordingly, we developed scales to measure motivational cognitions for functional goals (Motivational Thought Frequency, MTF; State Motivation, SM), based on the existing Craving Experience Questionnaire (CEQ). When applied to increasing exercise, MTF and SM showed the same three-factor structure as the CEQ (Intensity, Imagery, Availability). The current study tested the internal structure and concurrent validity of the MTF and SM Scales when applied to control of alcohol consumption (MTF-A; SM-A). Participants (N=417) were adult tertiary students, staff or community members who had recently engaged in high-risk drinking or were currently trying to control alcohol consumption. They completed an online survey comprising the MTF-A, SM-A, Alcohol Use Disorders Identification Test (AUDIT), Readiness to Change Questionnaire (RCQ) and demographics. Confirmatory Factor Analysis gave acceptable fit for the MTF-A, but required the loss of one SM-A item, and was improved by intercorrelations of error terms. Higher scores were associated with more severe problems on the AUDIT and with higher Contemplation and Action scores on the RCQ. The MTF-A and SM-A show potential as measures of motivation to control drinking. Future research will examine their predictive validity and sensitivity to change. The scales' application to both increasing functional and decreasing dysfunctional behaviours is consistent with EI Theory's contention that both goal types operate in similar ways. Copyright © 2016 Elsevier Ltd. All rights reserved.
Lwaleed, B A; Chisholm, M; Francis, J L
1999-01-01
Monocytes express tissue factor (mTF) in several conditions including cancer where levels may be valuable in assessing tumour presence and progression. Using a two-stage kinetic chromogenic assay (KCA), mTF levels were measured in controls [normal subjects (n = 60) and patients undergoing hernia repair or cholecystectomy (n = 60)], in patients with benign and malignant disease of the breast (n = 83) and of the large bowel (n = 62). This was performed under fresh (resting) conditions and after incubation for 6 h without (unstimulated) and with (stimulated) Escherichia coli endotoxin. The malignant groups showed higher mTF levels than each of the three controls for resting (P < 0.05 breast, P < 0.05 colorectal) unstimulated (P < 0.05 breast, P < 0.05 colorectal) and stimulated cells (P < 0.001 breast, P < 0.01 colorectal). Similarly, the benign inflammatory groups had higher mTF levels than controls for resting (P < 0.05 colorectal), unstimulated (P < 0.05 colorectal) and stimulated cells (P < 0.01 breast, P < 0.01 colorectal). There was no significant difference between malignant and benign inflammatory groups in each organ. mTF levels showed an increase corresponding to that of histological tumour progression and were higher in non-surviving patients. In conclusion, mTF levels are raised in malignant and inflammatory disease compared to controls and patients with non-inflammatory conditions. Stimulated cells give better discrimination between the groups and may be of value in identifying high risk individuals. mTF levels showed an association with tumour grade or stage and the patients' survival time. © 1999 Cancer Research Campaign PMID:10390009
Generic Sensor Modeling Using Pulse Method
NASA Technical Reports Server (NTRS)
Helder, Dennis L.; Choi, Taeyoung
2005-01-01
Recent development of high spatial resolution satellites such as IKONOS, Quickbird and Orbview enable observation of the Earth's surface with sub-meter resolution. Compared to the 30 meter resolution of Landsat 5 TM, the amount of information in the output image was dramatically increased. In this era of high spatial resolution, the estimation of spatial quality of images is gaining attention. Historically, the Modulation Transfer Function (MTF) concept has been used to estimate an imaging system's spatial quality. Sometimes classified by target shapes, various methods were developed in laboratory environment utilizing sinusoidal inputs, periodic bar patterns and narrow slits. On-orbit sensor MTF estimation was performed on 30-meter GSD Landsat4 Thematic Mapper (TM) data from the bridge pulse target as a pulse input . Because of a high resolution sensor s small Ground Sampling Distance (GSD), reasonably sized man-made edge, pulse, and impulse targets can be deployed on a uniform grassy area with accurate control of ground targets using tarps and convex mirrors. All the previous work cited calculated MTF without testing the MTF estimator's performance. In previous report, a numerical generic sensor model had been developed to simulate and improve the performance of on-orbit MTF estimating techniques. Results from the previous sensor modeling report that have been incorporated into standard MTF estimation work include Fermi edge detection and the newly developed 4th order modified Savitzky-Golay (MSG) interpolation technique. Noise sensitivity had been studied by performing simulations on known noise sources and a sensor model. Extensive investigation was done to characterize multi-resolution ground noise. Finally, angle simulation was tested by using synthetic pulse targets with angles from 2 to 15 degrees, several brightness levels, and different noise levels from both ground targets and imaging system. As a continuing research activity using the developed sensor model, this report was dedicated to MTF estimation via pulse input method characterization using the Fermi edge detection and 4th order MSG interpolation method. The relationship between pulse width and MTF value at Nyquist was studied including error detection and correction schemes. Pulse target angle sensitivity was studied by using synthetic targets angled from 2 to 12 degrees. In this report, from the ground and system noise simulation, a minimum SNR value was suggested for a stable MTF value at Nyquist for the pulse method. Target width error detection and adjustment technique based on a smooth transition of MTF profile is presented, which is specifically applicable only to the pulse method with 3 pixel wide targets.
The influence of focal spot blooming on high-contrast spatial resolution in CT imaging.
Grimes, Joshua; Duan, Xinhui; Yu, Lifeng; Halaweish, Ahmed F; Haag, Nicole; Leng, Shuai; McCollough, Cynthia
2015-10-01
The objective of this work was to investigate focal spot blooming effects on the spatial resolution of CT images and to evaluate an x-ray tube that uses dynamic focal spot control for minimizing focal spot blooming. The influence of increasing tube current at a fixed tube potential of 80 kV on high-contrast spatial resolution of seven different CT scanner models (scanners A-G), including one scanner that uses dynamic focal spot control to reduce focal spot blooming (scanner A), was evaluated. Spatial resolution was assessed using a wire phantom for the modulation transfer function (MTF) calculation and a copper disc phantom for measuring the slice sensitivity profile (SSP). The impact of varying the tube potential was investigated on two scanner models (scanners A and B) by measuring the MTF and SSP and also by using the resolution bar pattern module of the ACR CT phantom. The phantoms were scanned at 70-150 kV on scanner A and 80-140 kV on scanner B, with tube currents from 100 mA up to the maximum tube current available on each scanner. The images were reconstructed using a slice thickness of 0.6 mm with both smooth and sharp kernels. Additionally, focal spot size at varying tube potentials and currents was directly measured using pinhole and slit camera techniques. Evaluation of the MTF and SSP data from the 7 CT scanner models evaluated demonstrated decreased focal spot blooming for newer scanners, as evidenced by decreasing deviations in MTF and SSP as tube current varied. For scanners A and B, where focal spot blooming effects as a function of tube potential were assessed, the spatial resolution variation in the axial plane was much smaller on scanner A compared to scanner B as tube potential and current changed. On scanner A, the 50% MTF never decreased by more than 2% from the 50% MTF measured at 100 mA. On scanner B, the 50% MTF decreased by as much as 19% from the 50% MTF measured at 100 mA. Assessments of the SSP, the bar patterns in the ACR phantom and the pinhole and slit camera measurements were consistent with the MTF calculations. Focal spot blooming has a noticeable effect on spatial resolution in CT imaging. The focal spot shaping technology of scanner A greatly reduced blooming effects.
The Fresnel Diffraction: A Story of Light and Darkness
NASA Astrophysics Data System (ADS)
Aime, C.; Aristidi, É.; Rabbia, Y.
2013-03-01
In a first part of the paper we give a simple introduction to the free space propagation of light at the level of a Master degree in Physics. The presentation promotes linear filtering aspects at the expense of fundamental physics. Following the Huygens-Fresnel approach, the propagation of the wave writes as a convolution relationship, the impulse response being a quadratic phase factor. We give the corresponding filter in the Fourier plane. As an illustration, we describe the propagation of wave with a spatial sinusoidal amplitude, introduce lenses as quadratic phase transmissions, discuss their Fourier transform properties and give some properties of Soret screens. Classical diffractions of rectangular diaphragms are also given here. In a second part of the paper, the presentation turns into the use of external occulters in coronagraphy for the detection of exoplanets and the study of the solar corona. Making use of Lommel series expansions, we obtain the analytical expression for the diffraction of a circular opaque screen, giving thereby the complete formalism for the Arago-Poisson spot. We include there shaped occulters. The paper ends up with a brief application to incoherent imaging in astronomy.
Analysis and measurement of electromagnetic scattering by pyramidal and wedge absorbers
NASA Technical Reports Server (NTRS)
Dewitt, B. T.; Burnside, Walter D.
1986-01-01
By modifying the reflection coefficients in the Uniform Geometrical Theory of Diffraction a solution that approximates the scattering from a dielectric wedge is found. This solution agrees closely with the exact solution of Rawlins which is only valid for a few minor cases. This modification is then applied to the corner diffraction coefficient and combined with an equivalent current and geometrical optics solutions to model scattering from pyramid and wedge absorbers. Measured results from 12 inch pyramid absorbers from 2 to 18 GHz are compared to calculations assuming the returns add incoherently and assuming the returns add coherently. The measured results tend to be between the two curves. Measured results from the 8 inch wedge absorber are also compared to calculations with the return being dominated by the wedge diffraction. The procedures for measuring and specifying absorber performance are discussed and calibration equations are derived to calculate a reflection coefficient or a reflectivity using a reference sphere. Shaping changes to the present absorber designs are introduced to improve performance based on both high and low frequency analysis. Some prototypes were built and tested.
Giedroc, D P; Chen, X; Pennella, M A; LiWang, A C
2001-11-09
The human metalloregulatory transcription factor, metal-response element (MRE)-binding transcription factor-1 (MTF-1), contains six TFIIIA-type Cys(2)-His(2) motifs, each of which was projected to form well-structured betabetaalpha domains upon Zn(II) binding. In this report, the structure and backbone dynamics of a fragment containing the unusual C-terminal fingers F4-F6 has been investigated. (15)N heteronuclear single quantum coherence (HSQC) spectra of uniformly (15)N-labeled hMTF-zf46 show that Zn(II) induces the folding of hMTF-zf46. Analysis of the secondary structure of Zn(3) hMTF-zf46 determined by (13)Calpha chemical shift indexing and the magnitude of (3)J(Halpha-HN) clearly reveal that zinc fingers F4 and F6 adopt typical betabetaalpha structures. An analysis of the heteronuclear backbone (15)N relaxation dynamics behavior is consistent with this picture and further reveals independent tumbling of the finger domains in solution. Titration of apo-MTF-zf46 with Zn(II) reveals that the F4 domain binds Zn(II) significantly more tightly than do the other two finger domains. In contrast to fingers F4 and F6, the betabetaalpha fold of finger F5 is unstable and only partially populated at substoichiometric Zn(II); a slight molar excess of zinc results in severe conformational exchange broadening of all F5 NH cross-peaks. Finally, although Cd(II) binds to apo-hMTF-zf46 as revealed by intense S(-)-->Cd(II) absorption, a non-native structure results; addition of stoichiometric Zn(II) to the Cd(II) complex results in quantitative refolding of the betabetaalpha structure in F4 and F6. The functional implications of these results are discussed.
Bean Metal-Responsive Element-Binding Transcription Factor Confers Cadmium Resistance in Tobacco1
Sun, Na; Liu, Meng; Zhang, Wentao; Yang, Wanning; Bei, Xiujuan; Ma, Hui; Qiao, Fan; Qi, Xiaoting
2015-01-01
Cadmium (Cd) is highly toxic to plants. Modulation of Cd-responsive transcription is an important way for Cd detoxification in plants. Metal-responsive element (MRE) is originally described in animal metallothionein genes. Although functional MREs also exist in Cd-regulated plant genes, specific transcription factors that bind MRE to regulate Cd tolerance have not been identified. Previously, we showed that Cd-inducible bean (Phaseolus vulgaris) stress-related gene2 (PvSR2) produces a short (S) PvSR2 transcript (S-PvSR2) driven by an intronic promoter. Here, we demonstrate that S-PvSR2 encodes a bean MRE-binding transcription factor1 (PvMTF-1) that confers Cd tolerance in tobacco (Nicotiana tabacum). PvMTF-1 expression was up-regulated by Cd at the levels of RNA and protein. Importantly, expression of PvMTF-1 in tobacco enhanced Cd tolerance, indicating its role in regulating Cd resistance in planta. This was achieved through direct regulation of a feedback-insensitive Anthranilate Synthase α-2 chain gene (ASA2), which catalyzes the first step for tryptophan biosynthesis. In vitro and in vivo DNA-protein interaction studies further revealed that PvMTF-1 directly binds to the MRE in the ASA2 promoter, and this binding depends on the zinc finger-like motif of PvMTF-1. Through modulating ASA2 up-regulation by Cd, PvMTF-1 increased free tryptophan level and subsequently reduced Cd accumulation, thereby enhancing Cd tolerance of transgenic tobacco plants. Consistent with this observation, tobacco transiently overexpressing ASA2 also exhibited increased tolerance to Cd. We conclude that PvMTF-1 is a zinc finger-like transcription factor that links MRE to Cd resistance in transgenic tobacco through activation of tryptophan biosynthesis. PMID:25624396
Engineering of the Magnetized Target Fusion Propulsion System
NASA Technical Reports Server (NTRS)
Statham, G.; White, S.; Adams, R. B.; Thio, Y. C. F.; Santarius, J.; Alexander, R.; Chapman, J.; Fincher, S.; Philips, A.; Polsgrove, T.
2003-01-01
Engineering details are presented for a magnetized target fusion (MTF) propulsion system designed to support crewed missions to the outer solar system. Basic operation of an MTF propulsion system is introduced. Structural, thermal, radiation-management and electrical design details are presented. The propellant storage and supply system design is also presented. A propulsion system mass estimate and associated performance figures are given. The advantages of helium-3 as a fusion fuel for an advanced MTF system are discussed.
Hillmann, Kathrin; Garcia Bartels, Natalie; Kottner, Jan; Stroux, Andrea; Canfield, Douglas; Blume-Peytavi, Ulrike
2015-01-01
5% minoxidil formulations twice daily are effective in treating vertex male androgenetic alopecia (AGA); however, efficacy and safety data in frontotemporal regions are lacking. To assess the efficacy of 5% minoxidil topical foam (5% MTF) in the frontotemporal region of male AGA patients after 24 weeks of treatment compared to placebo treatment and to the vertex region. Seventy males with moderate AGA applied 5% MTF or placebo foam (plaTF) twice daily for 24 weeks in frontotemporal and vertex regions. Target area non-vellus hair count (TAHC) was the primary end point. Frontotemporal and vertex TAHC and target area cumulative non-vellus hair width (TAHW) showed similar responses to 5% MTF with significant increases up to week 16 compared to baseline (p < 0.001). After 24 weeks of treatment, frontotemporal TAHW increased significantly in the 5% MTF group compared to the plaTF group (p = 0.017), while TAHC showed a similar non-significant increase from baseline in both regions. At 24 weeks, 5% MTF users rated a significant improvement in scalp coverage for the frontotemporal (p = 0.016) and vertex areas (p = 0.027). 5% MTF twice a day promotes hair density and width in both frontotemporal and vertex regions in men with moderate stages of AGA. © 2015 S. Karger AG, Basel.
The effect of serum on monocyte tissue factor generation.
Edwards, R L; Perla, D
1984-09-01
Human monocytes generate the procoagulant tissue factor (MTF) following exposure to a variety of immune stimuli in vitro. The generation of MTF is modified by T cells, lymphokines, and immunoregulatory lipoproteins, and recent studies have shown that MTF can be activated in an immune-specific manner following exposure to antigen. We have examined the role of serum factors in the regulation of MTF generation. Low concentrations (less than 1%) of heat-inactivated normal human serum greatly enhanced MTF generation in cultures of normal peripheral blood mononuclear cells. The stimulatory effect was observed in cultures of both unstimulated cells and cells exposed to bacterial lipopolysaccharide. Stimulation was not observed at high serum concentrations (greater than 10%) and could not be explained by endotoxin contamination or activation of the assay system. Stimulatory activity was present in plasma and BaSO4-adsorbed plasma as well as autologous and allogeneic serum, was not abolished by removal of serum lipoproteins, and did not require the presence of T cells for its expression. Sera from 28 different normal volunteers were screened for stimulatory activity and demonstrated a wide variation in potency. These results suggest that a potent factor is present in sera that enhances the expression of MTF activity in vitro. This factor is distinct from previously described lipoprotein regulators and may play a role in the initiation of coagulation in both normal hemostasis and pathologic states.
Lawrence, Anne A
2010-04-01
There are two distinct subtypes of male-to-female (MtF) transsexuals: homosexual and nonhomosexual. The relative prevalence of these two subtypes varies dramatically between countries, but no explanation of this variability has yet been proposed. This study examined the hypothesis that the prevalence of nonhomosexual MtF transsexualism, relative to homosexual MtF transsexualism, would be higher in individualistic countries than in collectivistic countries. I analyzed data from 22 studies of MtF transsexualism, conducted in 16 countries, examining the association between percentage of nonhomosexual participants and Hofstede's (Culture's consequences: Comparing values, behaviors, institutions, and organizations across nations, 2001) Individualism Index (IDV). IDV accounted for 77% of observed variance in the percentage of nonhomosexual MtF participants (r = 0.88, p < .0001). Controlling for differences in national wealth and in Hofstede's other indices of societal values (Power Distance, Uncertainty Avoidance, and Masculinity) did not significantly change the ability of IDV to account for variance in the percentage of nonhomosexual participants. The factors that contribute to the observed association between societal individualism and the relative prevalence of nonhomosexual MtF transsexualism remain to be determined, but a greater tolerance within individualistic countries for socially disruptive gender transitions by nonhomosexual gender dysphoric men, and the availability within many collectivistic countries of socially approved transgender roles for pervasively feminine homosexual gender dysphoric men, are plausible contributors.
NASA Astrophysics Data System (ADS)
Petković, Dalibor; Shamshirband, Shahaboddin; Saboohi, Hadi; Ang, Tan Fong; Anuar, Nor Badrul; Rahman, Zulkanain Abdul; Pavlović, Nenad T.
2014-07-01
The quantitative assessment of image quality is an important consideration in any type of imaging system. The modulation transfer function (MTF) is a graphical description of the sharpness and contrast of an imaging system or of its individual components. The MTF is also known and spatial frequency response. The MTF curve has different meanings according to the corresponding frequency. The MTF of an optical system specifies the contrast transmitted by the system as a function of image size, and is determined by the inherent optical properties of the system. In this study, the polynomial and radial basis function (RBF) are applied as the kernel function of Support Vector Regression (SVR) to estimate and predict estimate MTF value of the actual optical system according to experimental tests. Instead of minimizing the observed training error, SVR_poly and SVR_rbf attempt to minimize the generalization error bound so as to achieve generalized performance. The experimental results show that an improvement in predictive accuracy and capability of generalization can be achieved by the SVR_rbf approach in compare to SVR_poly soft computing methodology.
Separation of presampling and postsampling modulation transfer functions in infrared sensor systems
NASA Astrophysics Data System (ADS)
Espinola, Richard L.; Olson, Jeffrey T.; O'Shea, Patrick D.; Hodgkin, Van A.; Jacobs, Eddie L.
2006-05-01
New methods of measuring the modulation transfer function (MTF) of electro-optical sensor systems are investigated. These methods are designed to allow the separation and extraction of presampling and postsampling components from the total system MTF. The presampling MTF includes all the effects prior to the sampling stage of the imaging process, such as optical blur and detector shape. The postsampling MTF includes all the effects after sampling, such as interpolation filters and display characteristics. Simulation and laboratory measurements are used to assess the utility of these techniques. Knowledge of these components and inclusion into sensor models, such as the U.S. Army RDECOM CERDEC Night Vision and Electronic Sensors Directorate's NVThermIP, will allow more accurate modeling and complete characterization of sensor performance.
Winkelmann, A; Nolze, G; Vespucci, S; Naresh-Kumar, G; Trager-Cowan, C; Vilalta-Clemente, A; Wilkinson, A J; Vos, M
2017-09-01
We analyse the signal formation process for scanning electron microscopic imaging applications on crystalline specimens. In accordance with previous investigations, we find nontrivial effects of incident beam diffraction on the backscattered electron distribution in energy and momentum. Specifically, incident beam diffraction causes angular changes of the backscattered electron distribution which we identify as the dominant mechanism underlying pseudocolour orientation imaging using multiple, angle-resolving detectors. Consequently, diffraction effects of the incident beam and their impact on the subsequent coherent and incoherent electron transport need to be taken into account for an in-depth theoretical modelling of the energy- and momentum distribution of electrons backscattered from crystalline sample regions. Our findings have implications for the level of theoretical detail that can be necessary for the interpretation of complex imaging modalities such as electron channelling contrast imaging (ECCI) of defects in crystals. If the solid angle of detection is limited to specific regions of the backscattered electron momentum distribution, the image contrast that is observed in ECCI and similar applications can be strongly affected by incident beam diffraction and topographic effects from the sample surface. As an application, we demonstrate characteristic changes in the resulting images if different properties of the backscattered electron distribution are used for the analysis of a GaN thin film sample containing dislocations. © 2017 The Authors. Journal of Microscopy published by JohnWiley & Sons Ltd on behalf of Royal Microscopical Society.
Objective evaluation of slanted edge charts
NASA Astrophysics Data System (ADS)
Hornung, Harvey (.
2015-01-01
Camera objective characterization methodologies are widely used in the digital camera industry. Most objective characterization systems rely on a chart with specific patterns, a software algorithm measures a degradation or difference between the captured image and the chart itself. The Spatial Frequency Response (SFR) method, which is part of the ISO 122331 standard, is now very commonly used in the imaging industry, it is a very convenient way to measure a camera Modulation transfer function (MTF). The SFR algorithm can measure frequencies beyond the Nyquist frequency thanks to super-resolution, so it does provide useful information on aliasing and can provide modulation for frequencies between half Nyquist and Nyquist on all color channels of a color sensor with a Bayer pattern. The measurement process relies on a chart that is simple to manufacture: a straight transition from a bright reflectance to a dark one (black and white for instance), while a sine chart requires handling precisely shades of gray which can also create all sort of issues with printers that rely on half-toning. However, no technology can create a perfect edge, so it is important to assess the quality of the chart and understand how it affects the accuracy of the measurement. In this article, I describe a protocol to characterize the MTF of a slanted edge chart, using a high-resolution flatbed scanner. The main idea is to use the RAW output of the scanner as a high-resolution micro-densitometer, since the signal is linear it is suitable to measure the chart MTF using the SFR algorithm. The scanner needs to be calibrated in sharpness: the scanner MTF is measured with a calibrated sine chart and inverted to compensate for the modulation loss from the scanner. Then the true chart MTF is computed. This article compares measured MTF from commercial charts and charts printed on printers, and also compares how of the contrast of the edge (using different shades of gray) can affect the chart MTF, then concludes on what distance range and camera resolution the chart can reliably measure the camera MTF.
On use of image quality metrics for perceptual blur modeling: image/video compression case
NASA Astrophysics Data System (ADS)
Cha, Jae H.; Olson, Jeffrey T.; Preece, Bradley L.; Espinola, Richard L.; Abbott, A. Lynn
2018-02-01
Linear system theory is employed to make target acquisition performance predictions for electro-optical/infrared imaging systems where the modulation transfer function (MTF) may be imposed from a nonlinear degradation process. Previous research relying on image quality metrics (IQM) methods, which heuristically estimate perceived MTF has supported that an average perceived MTF can be used to model some types of degradation such as image compression. Here, we discuss the validity of the IQM approach by mathematically analyzing the associated heuristics from the perspective of reliability, robustness, and tractability. Experiments with standard images compressed by x.264 encoding suggest that the compression degradation can be estimated by a perceived MTF within boundaries defined by well-behaved curves with marginal error. Our results confirm that the IQM linearizer methodology provides a credible tool for sensor performance modeling.
NASA Technical Reports Server (NTRS)
Weissman, D. E.; Johnson, J. W.
1984-01-01
The directional spectrum and the microwave modulation transfer function of ocean waves can be measured with the airborne two frequency scatterometer technique. Similar to tower based observations, the aircraft measurements of the Modulation Transfer Function (MTF) show that it is strongly affected by both wind speed and sea state. Also detected are small differences in the magnitudes of the MTF between downwind and upwind radar look directions, and variations with ocean wavenumber. The MTF inferred from the two frequency radar is larger than that measured using single frequency, wave orbital velocity techniques such as tower based radars or ROWS measurements from low altitude aircraft. Possible reasons for this are discussed. The ability to measure the ocean directional spectrum with the two frequency scatterometer, with supporting MTF data, is demonstrated.
NASA Technical Reports Server (NTRS)
Weissman, D. E.; Johnson, J. W.
1986-01-01
The directional spectrum and the microwave modulation transfer function of ocean waves can be measured with the airborne two frequency scatterometer technique. Similar to tower based observations, the aircraft measurements of the Modulation Transfer Function (MTF) show that it is strongly affected by both wind speed and sea state. Also detected are small differences in the magnitudes of the MTF between downwind and upwind radar look directions, and variations with ocean wavenumber. The MTF inferred from the two frequency radar is larger than that measured using single frequency, wave orbital velocity techniques such as tower based radars or ROWS measurements from low altitude aircraft. Possible reasons for this are discussed. The ability to measure the ocean directional spectrum with the two frequency scatterometer, with supporting MTF data, is demonstrated.
Spatial Resolution Characterization for QuickBird Image Products 2003-2004 Season
NASA Technical Reports Server (NTRS)
Blonski, Slawomir
2006-01-01
This presentation focuses on spatial resolution characterization for QuickBird panochromatic images in 2003-2004 and presents data measurements and analysis of SSC edge target deployment and edge response extraction and modeling. The results of the characterization are shown as values of the Modulation Transfer Function (MTF) at the Nyquist spatial frequency and as the Relative Edge Response (RER) components. The results show that RER is much less sensitive to accuracy of the curve fitting than the value of MTF at Nyquist frequency. Therefore, the RER/edge response slope is a more robust estimator of the digital image spatial resolution than the MTF. For the QuickBird panochromatic images, the RER is consistently equal to 0.5 for images processed with the Cubic Convolution resampling and to 0.8 for the MTF resampling.
[Evaluation of the resolving power of different angles in MPR images of 16DAS-MDCT].
Kimura, Mikio; Usui, Junshi; Nozawa, Takeo
2007-03-20
In this study, we evaluated the resolving power of three-dimensional (3D) multiplanar reformation (MPR) images with various angles by using 16 data acquisition system multi detector row computed tomography (16DAS-MDCT) . We reconstructed the MPR images using data with a 0.75 mm slice thickness of the axial image in this examination. To evaluate resolving power, we used an original new phantom (RC phantom) that can be positioned at any slice angle in MPR images. We measured the modulation transfer function (MTF) by using the methods of measuring pre-sampling MTF, and used Fourier transform of image data of the square wave chart. The scan condition and image reconstruction condition that were adopted in this study correspond to the condition that we use for three-dimensional computed tomographic angiography (3D-CTA) examination of the head in our hospital. The MTF of MPR images showed minimum values at slice angles in parallel with the axial slice, and showed maximum values at the sagittal slice and coronal slice angles that are parallel to the Z-axis. With an oblique MPR image, MTF did not change with angle changes in the oblique sagittal slice plane, but in the oblique coronal slice plane, MTF increased as the tilt angle increased from the axial plane to the Z plane. As a result, we could evaluate the resolving power of a head 3D image by measuring the MTF of the axial image and sagittal image or the coronal image.
Warnes, G; Biggerstaff, J P; Francis, J L
1998-07-01
Recent studies have investigated the use of anti-inflammatory cytokine, interleukin 10 (IL-10) to control the development of disseminated intravascular coagulation (DIC) in sepsis by down-regulation of monocyte tissue factor (MTF) induced by lipopolysaccharide (LPS) in the initial phase of the disease. In vitro and in vivo human studies have shown that a minimal (<1 h) delay in IL-10 treatment significantly reduces the cytokines ability to inhibit LPS-induced MTF expression and the end products of coagulation. In this whole blood in vitro study we investigated the role of lymphocyte and platelet interactions with monocytes to up-regulate MTF expression in the presence of IL-10 in the initial phase of exposure to LPS. Individual blockade of monocyte B7 or platelet P-selectin significantly (35%) reduced MTF expression (P<0.05). IL-10 showed a dose-dependent inhibition of LPS (0.1 microg/ml) induced MTF expression, with 56% inhibition at 1 ng/ml, maximizing at 5 ng/ml IL-10 (75%; P<0.05). Simultaneous exposure to LPS and IL-10 (1 ng/ml) or addition of IL-10 1 h after LPS, with individual B7 and P-selectin blockade significantly enhanced the inhibition of MTF expression by IL-10 (P<0.05). We conclude that the efficacy of IL-10 to control DIC could be enhanced by a simultaneous B7 and P-selectin blockade.
Modeling and measurement of the detector presampling MTF of a variable resolution x-ray CT scanner.
Melnyk, Roman; DiBianca, Frank A
2007-03-01
The detector presampling modulation transfer function (MTF) of a 576-channel variable resolution x-ray (VRX) computed tomography (CT) scanner was evaluated in this study. The scanner employs a VRX detector, which provides increased spatial resolution by matching the scanner's field of view (FOV) to the size of an object being imaged. Because spatial resolution is the parameter the scanner promises to improve, the evaluation of this resolution is important. The scanner's pre-reconstruction spatial resolution, represented by the detector presampling MTF, was evaluated using both modeling (Monte Carlo simulation) and measurement (the moving slit method). The theoretical results show the increase in the cutoff frequency of the detector presampling MTF from 1.39 to 43.38 cycles/mm as the FOV of the VRX CT scanner decreases from 32 to 1 cm. The experimental results are in reasonable agreement with the theoretical data. Some discrepancies between the measured and the modeled detector presampling MTFs can be explained by the limitations of the model. At small FOVs (1-8 cm), the MTF measurements were limited by the size of the focal spot. The obtained results are important for further development of the VRX CT scanner.
Modeling and measurement of the detector presampling MTF of a variable resolution x-ray CT scanner
Melnyk, Roman; DiBianca, Frank A.
2007-01-01
The detector presampling MTF of a 576-channel variable resolution x-ray (VRX) CT scanner was evaluated in this study. The scanner employs a VRX detector, which provides increased spatial resolution by matching the scanner’s field of view (FOV) to the size of an object being imaged. Because spatial resolution is the parameter the scanner promises to improve, the evaluation of this resolution is important. The scanner’s pre-reconstruction spatial resolution, represented by the detector presampling MTF, was evaluated using both modeling (Monte Carlo simulation) and measurement (the moving slit method). The theoretical results show the increase in the cutoff frequency of the detector presampling MTF from 1.39 cy/mm to 43.38 cy/mm as the FOV of the VRX CT scanner decreases from 32 cm to 1 cm. The experimental results are in reasonable agreement with the theoretical data. Some discrepancies between the measured and the modeled detector presampling MTFs can be explained by the limitations of the model. At small FOVs (1–8 cm), the MTF measurements were limited by the size of the focal spot. The obtained results are important for further development of the VRX CT scanner. PMID:17369872
Autogynephilia: an underappreciated paraphilia.
Lawrence, Anne A
2011-01-01
Autogynephilia is defined as a male's propensity to be sexually aroused by the thought of himself as a female. It is the paraphilia that is theorized to underlie transvestism and some forms of male-to-female (MtF) transsexualism. Autogynephilia encompasses sexual arousal with cross-dressing and cross-gender expression that does not involve women's clothing per se. The concept of autogynephilia defines a typology of MtF transsexualism and offers a theory of motivation for one type of MtF transsexualism. Autogynephilia resembles a sexual orientation in that it involves elements of idealization and attachment as well as erotic desire. Nearly 3% of men in Western countries may experience autogynephilia; its most severe manifestation, MtF transsexualism, is rare but increasing in prevalence. Some theorists and clinicians reject the transsexual typology and theory of motivation derived from autogynephilia; their objections suggest a need for additional research. The concept of autogynephilia can assist clinicians in understanding some otherwise puzzling manifestations of nonhomosexual MtF transsexualism. Autogynephilia exemplifies an unusual paraphilic category called 'erotic target identity inversions', in which men desire to impersonate or turn their bodies into facsimiles of the persons or things to which they are sexually attracted. Copyright © 2011 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Dong, Jianing; Zhang, Yinchao; Chen, Siying; Chen, He; Guo, Pan
2017-02-01
In order to improve the remote target detection ability of infrared (IR) images effectively, an infrared telephoto objective for 3μm 5μm and 8μm 12μm dual wave-band is designed for 640 pixel×512 pixel infrared CCD detector. The effects of the surrounding environmental temperature are analyzed and the refractive diffractive hybrid thermal compensation is discussed. The focal length of the system is 200mm, the relative aperture is 1:2.2 and the field of view is 7°. The infrared dual band telephoto system with small volume and compact structure is designed in a large range of temperature. The system is composed of four lenses with only three materials of zinc sulfide, zinc selenide and germanium to compensate for the temperature. The image quality of the system is evaluated by ZEMAX optical design software. The results show that the modulation transfer function (MTF) for each field of view at cut-off frequency of 17 lp/mm are respectively greater than 0.6 and 0.4 which approaches the diffraction limit. The telephoto objective has favorable performance at the working temperature of -40°C +60°C. The relative aperture, field of view, and focal length are same for both spectral regions. The system meets the requirements of technical specification.
OrbView-3 Technical Performance Evaluation 2005: Modulation Transfer Function
NASA Technical Reports Server (NTRS)
Cole, Aaron
2007-01-01
The Technical performance evaluation of OrbView-3 using the Modulation Transfer Function (MTF) is presented. The contents include: 1) MTF Results and Methodology; 2) Radiometric Calibration Methodology; and 3) Relative Radiometric Assessment Results
Zinc-induced Dnmt1 expression involves antagonism between MTF-1 and nuclear receptor SHP
Zhang, Yuxia; Andrews, Glen K.; Wang, Li
2012-01-01
Dnmt1 is frequently overexpressed in cancers, which contributes significantly to cancer-associated epigenetic silencing of tumor suppressor genes. However, the mechanism of Dnmt1 overexpression remains elusive. Herein, we elucidate a pathway through which nuclear receptor SHP inhibits zinc-dependent induction of Dnmt1 by antagonizing metal-responsive transcription factor-1 (MTF-1). Zinc treatment induces Dnmt1 transcription by increasing the occupancy of MTF-1 on the Dnmt1 promoter while decreasing SHP expression. SHP in turn represses MTF-1 expression and abolishes zinc-mediated changes in the chromatin configuration of the Dnmt1 promoter. Dnmt1 expression is increased in SHP-knockout (sko) mice but decreased in SHP-transgenic (stg) mice. In human hepatocellular carcinoma (HCC), increased DNMT1 expression is negatively correlated with SHP levels. Our study provides a molecular explanation for increased Dnmt1 expression in HCC and highlights SHP as a potential therapeutic target. PMID:22362755
1967-01-01
This photograph is a view of the Saturn V S-IC-5 (first) flight stage being hoisted into the S-IC-B1 test stand at the Mississippi Test Facility (MTF), Bay St. Louis, Mississippi. Begirning operations in 1966, the MTF has two test stands, a dual-position structure for running the S-IC stage at full throttle, and two separate stands for the S-II (Saturn V third) stage. It became the focus of the static test firing program. The completed S-IC stage was shipped from Michoud Assembly Facility (MAF) to the MTF. The stage was then installed into the 124-meter-high test stand for static firing tests before shipment to the Kennedy Space Center for final assembly of the Saturn V vehicle. The MTF was renamed to the National Space Technology Laboratory (NSTL) in 1974 and later to the Stennis Space Center (SSC) in May 1988.
1967-01-01
This photograph is a view of the Saturn V S-IC (first) test stage being hoisted into the S-IC-B1 test stand at the Mississippi Test Facility (MTF), Bay St. Louis, Mississippi. This stage was used to prove the operational readiness of the stand. Begirning operations in 1966, the MTF has two test stands; a dual-position structure for running the S-IC stage at full throttle, and two separate stands for the S-II (Saturn V third) stage. It became the focus of the static test firing program. The completed S-IC stage was shipped from the Michoud Assembly Facility (MAF) to the MTF. The stage was then installed into the 124-meter-high test stand for static firing tests before shipment to the Kennedy Space Center for final assembly of the Saturn V vehicle. The MTF was renamed to the National Space Technology Laboratory (NSTL) in 1974 and later to the Stennis Space Center (SSC) in May 1988.
1967-08-01
This photograph is a view of the Saturn V S-IC-5 (first) flight stage static test firing at the S-IC-B1 test stand at the Mississippi Test Facility (MTF), Bay St. Louis, Mississippi. Begirning operations in 1966, the MTF has two test stands, a dual-position structure for running the S-IC stage at full throttle, and two separate stands for the S-II (Saturn V third) stage. It became the focus of the static test firing program. The completed S-IC stage was shipped from Michoud Assembly Facility (MAF) to the MTF. The stage was then installed into the 407-foot-high test stand for the static firing tests before shipment to the Kennedy Space Center for final assembly of the Saturn V vehicle. The MTF was renamed to the National Space Technology Laboratory (NSTL) in 1974 and later to the Stennis Space Center (SSC) in May 1988.
HIV Prevalence and Risk Behaviors in Male to Female (MTF) Transgender Persons in Tijuana, Mexico.
Salas-Espinoza, Kristian Jesús; Menchaca-Diaz, Rufino; Patterson, Thomas L; Urada, Lianne A; Smith, Davey; Strathdee, Steffanie A; Pitpitan, Eileen V
2017-12-01
Compared to HIV research on men who have sex with men, less is known about the risks and vulnerabilities for HIV among Male to Female (MTF) transgender persons, particularly in different geographic regions like Mexico. In Tijuana, Mexico, a border city experiencing a dynamic HIV epidemic, no precedent data exists on the MTF transgender population. Our aims were to estimate HIV prevalence and examine the behaviors and characteristics of the population. We conducted a cross-sectional study of 100 MTF transgender persons recruited through time location sampling in 2012. Participants underwent interviewer-administered (paper and pen) surveys and rapid tests for HIV. Descriptive univariate analyses were conducted on various factors, including sociodemographics, substance use, accessing social services (requested vs. received), stigma, and sex behaviors. A total of 22% tested positive for HIV, a prevalence higher than other key populations at risk for HIV in Tijuana.
Yang, Hao; MacLaren, Ian; Jones, Lewys; ...
2017-04-01
Recent development in fast pixelated detector technology has allowed a two dimensional diffraction pattern to be recorded at every probe position of a two dimensional raster scan in a scanning transmission electron microscope (STEM), forming an information-rich four dimensional (4D) dataset. Electron ptychography has been shown to enable efficient coherent phase imaging of weakly scattering objects from a 4D dataset recorded using a focused electron probe, which is optimised for simultaneous incoherent Z-contrast imaging and spectroscopy in STEM. Thus coherent phase contrast and incoherent Z-contrast imaging modes can be efficiently combined to provide a good sensitivity of both light andmore » heavy elements at atomic resolution. Here, we explore the application of electron ptychography for atomic resolution imaging of strongly scattering crystalline specimens, and present experiments on imaging crystalline specimens including samples containing defects, under dynamical channelling conditions using an aberration corrected microscope. A ptychographic reconstruction method called Wigner distribution deconvolution (WDD) was implemented. Our experimental results and simulation results suggest that ptychography provides a readily interpretable phase image and great sensitivity for imaging light elements at atomic resolution in relatively thin crystalline materials.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Song, Gian; Sun, Zhiqian; Li, Lin
There have been numerous efforts to develop creep-resistant materials strengthened by incoherent particles at high temperatures and stresses in response to future energy needs for steam turbines in thermal-power plants. However, the microstructural instability of the incoherent-particle-strengthened ferritic steels limits their application to temperatures below 900 K. Here, we report a novel ferritic alloy with the excellent creep resistance enhanced by coherent hierarchical precipitates, using the integrated experimental (transmission-electron microscopy/scanning-transmission-electron microscopy, in-situ neutron diffraction, and atom-probe tomography) and theoretical (crystal-plasticity finite-element modeling) approaches. This alloy is strengthened by nano-scaled L21-Ni2TiAl (Heusler phase)-based precipitates, which themselves contain coherent nano-scaled B2 zones.more » These coherent hierarchical precipitates are uniformly distributed within the Fe matrix. Our hierarchical structure material exhibits the superior creep resistance at 973 K in terms of the minimal creep rate, which is four orders of magnitude lower than that of conventional ferritic steels. These results provide a new alloy-design strategy using the novel concept of hierarchical precipitates and the fundamental science for developing creep-resistant ferritic alloys. Finally, the present research will broaden the applications of ferritic alloys to higher temperatures.« less
Effects of intraocular lenses with different diopters on chromatic aberrations in human eye models.
Song, Hui; Yuan, Xiaoyong; Tang, Xin
2016-01-11
In this study, the effects of intraocular lenses (IOLs) with different diopters (D) on chromatic aberration were investigated in human eye models, and the influences of the central thickness of IOLs on chromatic aberration were compared. A Liou-Brennan-based IOL eye model was constructed using ZEMAX optical design software. Spherical IOLs with different diopters (AR40e, AMO Company, USA) were implanted; modulation transfer function (MTF) values at 3 mm of pupil diameter and from 0 to out-of-focus blur were collected and graphed. MTF values, measured at 555 nm of monochromatic light under each spatial frequency, were significantly higher than the values measured at 470 to 650 nm of polychromatic light. The influences of chromatic aberration on MTF values decreased with the increase in IOL diopter when the spatial frequency was ≤12 c/d, while increased effects were observed when the spatial frequency was ≥15 c/d. The MTF values of each IOL eye model were significantly lower than the MTF values of the Liou-Brennan eye models when measured at 555 nm of monochromatic light and at 470 to 650 nm of polychromatic light. The MTF values were also found to be increased with the increase in IOL diopter. With higher diopters of IOLs, the central thickness increased accordingly, which could have created increased chromatic aberration and decreased the retinal image quality. To improve the postoperative visual quality, IOLs with lower chromatic aberration should be selected for patients with short axial lengths.
MONITORING THE FUTURE (MTF) SURVEY
Monitoring The Future (MTF) is an ongoing study of the behaviors, attitudes, and values of American secondary school students, college students, and young adults, conducted by the University of Michigan's Institute for Social Research and funded by the National Institute on Drug ...
Pan, Patrick J; Bansal, Anshuman K; Genshaft, Scott J; Kim, Grace H; Suh, Robert D; Abtin, Fereidoun
2018-05-01
To determine size of ablation zone and pulmonary hemorrhage in double-freeze (DF) vs modified triple-freeze (mTF) cryoablation protocols with different probe sizes in porcine lung. In 10 healthy adult pigs, 20 pulmonary cryoablations were performed using either a 2.4-mm or a 1.7-mm probe. Either conventional DF or mTF protocol was used. Serial noncontrast CT scans were performed during ablations. Ablation iceball and hemorrhage volumes were measured and compared between protocols and probe sizes. With 1.7-mm probe, greater peak iceball volume was observed with DF compared with mTF, although difference was not statistically significant (16.1 mL ± 1.9 vs 8.8 mL ± 3.6, P = .07). With 2.4-mm probe, DF and mTF produced similar peak iceball volumes (14.0 mL ± 2.8 vs 14.6 mL ± 2.7, P = .88). Midcycle hemorrhage was significantly larger with DF with the 1.7-mm probe (94.3 mL ± 22.2 vs 19.6 mL ± 2.1, P = .02) and with both sizes combined (93.2 mL ± 17.5 vs. 50.9 mL ± 12.6, P = .048). Rate of hemorrhage increase was significantly higher in DF (10.4 mL/min vs 5.1 mL/min, P = .003). End-cycle hemorrhage was visibly larger in DF compared with mTF across probe sizes, although differences were not statistically significant (P = .14 for 1.7 mm probe, P = .18 for 2.4 mm probe, and P = .07 for both probes combined). Rate of increase in hemorrhage during the last thaw period was not statistically different between DF and mTF (3.0 mL/min vs 2.8 mL/min, P = .992). mTF reduced rate of midcycle hemorrhage compared with DF. With mTF, midcycle hemorrhage was significantly smaller with 1.7-mm probe; although noticeably smaller with 2.4-mm probe, statistical significance was not achieved. Iceball size was not significantly different across both protocols and probe types. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Sociodemographic Study of Danish Individuals Diagnosed with Transsexualism.
Simonsen, Rikke; Hald, Gert Martin; Giraldi, Annamaria; Kristensen, Ellids
2015-06-01
Male-to-female (MtF) and female-to-male (FtM) individuals with transsexualism (International Classification of Diseases-10) may differ in core clinical and sociodemographic variables such as age, sexual orientation, marriage and parenthood, school, educational level, and employment. Assessing and understanding the implication of such differences may be a key to developing appropriate and effective treatment and intervention strategies for this group. However, research in the area remains sparse and is often on small populations, making the generalization of results from current studies on individuals diagnosed with transsexualism difficult. (i) To describe and assess key sociodemographic and treatment-related differences between MtF and FtM individuals in a Danish population of individuals diagnosed with transsexualism; (ii) to assess possible implications of such difference, if any, for clinical treatment initiatives for individuals diagnosed with transsexualism. Follow-up of 108 individuals who had permission to undergo sex reassignment surgery (SRS, meaning castration and genital plastic surgery) over a 30-year period from 1978 to 2008 through the Gender Identity Unit in Copenhagen, Denmark. The individuals were identified through Social Security numbers. Clinical and sociodemographic data from medical records were collected. The sex ratio was 1.16:1 (MtF : FtM). Mean age at first referral was 26.9 (standard deviation [SD] 8.8) years for FtM and 30.2 (SD 9.7) for MtF individuals. Compared with MtF, FtM had a significantly lower onset age (before 12 years of age) and lower age when permission for SRS was granted. Further, FtM individuals were significantly more often gynephilic (sexually attracted to females) during research period and less likely to start self-initiated hormonal sex reassignment (SR) (treatment with cross-sex hormones). The MtF and FtM groups did not differ in years of school, educational level, employment, or engagement in marriage and cohabitation. As approximately half of MtF started cross-sex hormonal SR without attending a gender unit, future treatment needs to focus on this group of MtF individuals in order to accommodate the medical risks of self-initiated hormonal treatment.Earlier intervention with adolescents appears necessary since three-quarters of FtM individuals before age 12 had problems with their assigned sex. For both MtF and FtM, we found problems in areas of school, education, and employment and recommend further help in these core areas.
Structural molecular biology: Recent results from neutron diffraction
NASA Astrophysics Data System (ADS)
Timmins, Peter A.
1995-02-01
Neutron diffraction is of importance in structural biology at several different levels of resolution. In most cases the unique possibility arising from deuterium labelling or contrast variation is of fundamental importance in providing information complementary to that which can be obtained from X-ray diffraction. At high resolution, neutron crystallography of proteins allows the location of hydrogen atoms in the molecule or of the hydration water, both of which may be central to biological activity. A major difficulty in this field has been the poor signal-to-noise ratio of the data arising not only from relatively low beam intensities and small crystals but, most importantly from the incoherent background due to hydrogen atoms in the sample. Modern methods of molecular biology now offer ways of producing fully deuterated proteins by cloning in bacteria grown on fully deuterated media. At a slightly lower resolution, there are a number of systems which may be ordered in one or two dimensions. This is the case in the purple membrane where neutron diffraction with deuterium labelling has complemented high resolution electron diffraction. Finally there is a class of very large macromolecular systems which can be crystallised and have been studied by X-ray diffraction but in which part of the structure is locally disordered and usually has insufficient contrast to be seen with X-rays. In this case the use of H 2O/D 2O contrast variation allows these components to be located. Examples of this are the nucleic acid in virus structures and detergent bound to membrane proteins.
Macromolecular diffractive imaging using imperfect crystals
Ayyer, Kartik; Yefanov, Oleksandr; Oberthür, Dominik; Roy-Chowdhury, Shatabdi; Galli, Lorenzo; Mariani, Valerio; Basu, Shibom; Coe, Jesse; Conrad, Chelsie E.; Fromme, Raimund; Schaffer, Alexander; Dörner, Katerina; James, Daniel; Kupitz, Christopher; Metz, Markus; Nelson, Garrett; Lourdu Xavier, Paulraj; Beyerlein, Kenneth R.; Schmidt, Marius; Sarrou, Iosifina; Spence, John C. H.; Weierstall, Uwe; White, Thomas A.; Yang, Jay-How; Zhao, Yun; Liang, Mengning; Aquila, Andrew; Hunter, Mark S.; Robinson, Joseph S.; Koglin, Jason E.; Boutet, Sébastien; Fromme, Petra; Barty, Anton; Chapman, Henry N.
2016-01-01
The three-dimensional structures of macromolecules and their complexes are predominantly elucidated by X-ray protein crystallography. A major limitation is access to high-quality crystals, to ensure X-ray diffraction extends to sufficiently large scattering angles and hence yields sufficiently high-resolution information that the crystal structure can be solved. The observation that crystals with shrunken unit-cell volumes and tighter macromolecular packing often produce higher-resolution Bragg peaks1,2 hints that crystallographic resolution for some macromolecules may be limited not by their heterogeneity but rather by a deviation of strict positional ordering of the crystalline lattice. Such displacements of molecules from the ideal lattice give rise to a continuous diffraction pattern, equal to the incoherent sum of diffraction from rigid single molecular complexes aligned along several discrete crystallographic orientations and hence with an increased information content3. Although such continuous diffraction patterns have long been observed—and are of interest as a source of information about the dynamics of proteins4 —they have not been used for structure determination. Here we show for crystals of the integral membrane protein complex photosystem II that lattice disorder increases the information content and the resolution of the diffraction pattern well beyond the 4.5 Å limit of measurable Bragg peaks, which allows us to directly phase5 the pattern. With the molecular envelope conventionally determined at 4.5 Å as a constraint, we then obtain a static image of the photosystem II dimer at 3.5 Å resolution. This result shows that continuous diffraction can be used to overcome long-supposed resolution limits of macromolecular crystallography, with a method that puts great value in commonly encountered imperfect crystals and opens up the possibility for model-free phasing6,7. PMID:26863980
Dark incoherent soliton splitting and "phase-memory" effects: Theory and experiment.
Coskun, T H; Christodoulides, D N; Chen, Z; Segev, M
1999-05-01
We report on an experimental observation of dark incoherent soliton Y splitting. The effects of incoherence on the evolution of incoherent dark soliton doublets are investigated both theoretically and experimentally. We show that the dynamics of these incoherent self-trapped entities are associated with strong "phase-memory" effects that are otherwise absent in the linear regime.
Theory of lidar method for measurement of the modulation transfer function of water layers.
Dolin, Lev S
2013-01-10
We develop a method to evaluate the modulation transfer function (MTF) of a water layer from the characteristics of lidar signal backscattered by water volume. We propose several designs of a lidar system for remote measurement of the MTF and the procedure to determine optical properties of water using the measured MTF. We discuss a laser system for sea-bottom imaging that accounts for the influence of water slab on the image structure and allows for correction of image distortions caused by light scattering in water. © 2013 Optical Society of America
NASA Astrophysics Data System (ADS)
Han, Lu; Gao, Kun; Gong, Chen; Zhu, Zhenyu; Guo, Yue
2017-08-01
On-orbit Modulation Transfer Function (MTF) is an important indicator to evaluate the performance of the optical remote sensors in a satellite. There are many methods to estimate MTF, such as pinhole method, slit method and so on. Among them, knife-edge method is quite efficient, easy-to-use and recommended in ISO12233 standard for the wholefrequency MTF curve acquisition. However, the accuracy of the algorithm is affected by Edge Spread Function (ESF) fitting accuracy significantly, which limits the range of application. So in this paper, an optimized knife-edge method using Powell algorithm is proposed to improve the ESF fitting precision. Fermi function model is the most popular ESF fitting model, yet it is vulnerable to the initial values of the parameters. Considering the characteristics of simple and fast convergence, Powell algorithm is applied to fit the accurate parameters adaptively with the insensitivity to the initial parameters. Numerical simulation results reveal the accuracy and robustness of the optimized algorithm under different SNR, edge direction and leaning angles conditions. Experimental results using images of the camera in ZY-3 satellite show that this method is more accurate than the standard knife-edge method of ISO12233 in MTF estimation.
Lawrence, Anne A
2007-01-01
The increasing prevalence of male-to-female (MtF) transsexualism in Western countries is largely due to the growing number of MtF transsexuals who have a history of sexual arousal with cross-dressing or cross-gender fantasy. Ray Blanchard proposed that these transsexuals have a paraphilia he called autogynephilia, which is the propensity to be sexually aroused by the thought or image of oneself as female. Autogynephilia defines a transsexual typology and provides a theory of transsexual motivation, in that Blanchard proposed that MtF transsexuals are either sexually attracted exclusively to men (homosexual) or are sexually attracted primarily to the thought or image of themselves as female (autogynephilic), and that autogynephilic transsexuals seek sex reassignment to actualize their autogynephilic desires. Despite growing professional acceptance, Blanchard's formulation is rejected by some MtF transsexuals as inconsistent with their experience. This rejection, I argue, results largely from the misconception that autogynephilia is a purely erotic phenomenon. Autogynephilia can more accurately be conceptualized as a type of sexual orientation and as a variety of romantic love, involving both erotic and affectional or attachment-based elements. This broader conception of autogynephilia addresses many of the objections to Blanchard's theory and is consistent with a variety of clinical observations concerning autogynephilic MtF transsexualism.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoshida, Koji; Baron, Alfred Q. R.; Uchiyama, Hiroshi
We investigated hydrated antifreeze protein type III (AFP III) powder with a hydration level h (=mass of water/mass of protein) of 0.4 in the temperature range between 180 K and 298 K using X-ray diffraction and inelastic X-ray scattering (IXS). The X-ray diffraction data showed smooth, largely monotonic changes between 180 K and 298 K without freezing water. Meanwhile, the collective dynamics observed by IXS showed a strong change in the sound velocity at 180 K, after being largely temperature independent at higher temperatures (298–220 K). We interpret this change in terms of the dynamic transition previously discussed using othermore » probes including THz IR absorption spectroscopy and incoherent elastic and quasi-elastic neutron scattering. This finding suggests that the dynamic transition of hydrated proteins is observable on the subpicosecond time scale as well as nano- and pico-second scales, both in collective dynamics from IXS and single particle dynamics from neutron scattering. Moreover, it is most likely that the dynamic transition of hydrated AFP III is not directly correlated with its hydration structure.« less
NASA Astrophysics Data System (ADS)
Yoshida, Koji; Baron, Alfred Q. R.; Uchiyama, Hiroshi; Tsutsui, Satoshi; Yamaguchi, Toshio
2016-04-01
We investigated hydrated antifreeze protein type III (AFP III) powder with a hydration level h (=mass of water/mass of protein) of 0.4 in the temperature range between 180 K and 298 K using X-ray diffraction and inelastic X-ray scattering (IXS). The X-ray diffraction data showed smooth, largely monotonic changes between 180 K and 298 K without freezing water. Meanwhile, the collective dynamics observed by IXS showed a strong change in the sound velocity at 180 K, after being largely temperature independent at higher temperatures (298-220 K). We interpret this change in terms of the dynamic transition previously discussed using other probes including THz IR absorption spectroscopy and incoherent elastic and quasi-elastic neutron scattering. This finding suggests that the dynamic transition of hydrated proteins is observable on the subpicosecond time scale as well as nano- and pico-second scales, both in collective dynamics from IXS and single particle dynamics from neutron scattering. Moreover, it is most likely that the dynamic transition of hydrated AFP III is not directly correlated with its hydration structure.
Yoshida, Koji; Baron, Alfred Q R; Uchiyama, Hiroshi; Tsutsui, Satoshi; Yamaguchi, Toshio
2016-04-07
We investigated hydrated antifreeze protein type III (AFP III) powder with a hydration level h (=mass of water/mass of protein) of 0.4 in the temperature range between 180 K and 298 K using X-ray diffraction and inelastic X-ray scattering (IXS). The X-ray diffraction data showed smooth, largely monotonic changes between 180 K and 298 K without freezing water. Meanwhile, the collective dynamics observed by IXS showed a strong change in the sound velocity at 180 K, after being largely temperature independent at higher temperatures (298-220 K). We interpret this change in terms of the dynamic transition previously discussed using other probes including THz IR absorption spectroscopy and incoherent elastic and quasi-elastic neutron scattering. This finding suggests that the dynamic transition of hydrated proteins is observable on the subpicosecond time scale as well as nano- and pico-second scales, both in collective dynamics from IXS and single particle dynamics from neutron scattering. Moreover, it is most likely that the dynamic transition of hydrated AFP III is not directly correlated with its hydration structure.
Super-resolution optical telescopes with local light diffraction shrinkage
Wang, Changtao; Tang, Dongliang; Wang, Yanqin; Zhao, Zeyu; Wang, Jiong; Pu, Mingbo; Zhang, Yudong; Yan, Wei; Gao, Ping; Luo, Xiangang
2015-01-01
Suffering from giant size of objective lenses and infeasible manipulations of distant targets, telescopes could not seek helps from present super-resolution imaging, such as scanning near-field optical microscopy, perfect lens and stimulated emission depletion microscopy. In this paper, local light diffraction shrinkage associated with optical super-oscillatory phenomenon is proposed for real-time and optically restoring super-resolution imaging information in a telescope system. It is found that fine target features concealed in diffraction-limited optical images of a telescope could be observed in a small local field of view, benefiting from a relayed metasurface-based super-oscillatory imaging optics in which some local Fourier components beyond the cut-off frequency of telescope could be restored. As experimental examples, a minimal resolution to 0.55 of Rayleigh criterion is obtained, and imaging complex targets and large targets by superimposing multiple local fields of views are demonstrated as well. This investigation provides an access for real-time, incoherent and super-resolution telescopes without the manipulation of distant targets. More importantly, it gives counterintuitive evidence to the common knowledge that relayed optics could not deliver more imaging details than objective systems. PMID:26677820
Design of airborne imaging spectrometer based on curved prism
NASA Astrophysics Data System (ADS)
Nie, Yunfeng; Xiangli, Bin; Zhou, Jinsong; Wei, Xiaoxiao
2011-11-01
A novel moderate-resolution imaging spectrometer spreading from visible wavelength to near infrared wavelength range with a spectral resolution of 10 nm, which combines curved prisms with the Offner configuration, is introduced. Compared to conventional imaging spectrometers based on dispersive prism or diffractive grating, this design possesses characteristics of small size, compact structure, low mass as well as little spectral line curve (smile) and spectral band curve (keystone or frown). Besides, the usage of compound curved prisms with two or more different materials can greatly reduce the nonlinearity inevitably brought by prismatic dispersion. The utilization ratio of light radiation is much higher than imaging spectrometer of the same type based on combination of diffractive grating and concentric optics. In this paper, the Seidel aberration theory of curved prism and the optical principles of Offner configuration are illuminated firstly. Then the optical design layout of the spectrometer is presented, and the performance evaluation of this design, including spot diagram and MTF, is analyzed. To step further, several types of telescope matching this system are provided. This work provides an innovational perspective upon optical system design of airborne spectral imagers; therefore, it can offer theoretic guide for imaging spectrometer of the same kind.
Viral hepatitis screening in transgender patients undergoing gender identity hormonal therapy.
Mangla, Neeraj; Mamun, Rifat; Weisberg, Ilan S
2017-11-01
Viral hepatitis is a global health issue and can lead to cirrhosis, liver failure, and hepatocellular carcinoma. Guidelines for viral hepatitis screening in the transgender population do not exist. Transgender patients may be at higher risk for contracting viral hepatitis due to socioeconomic and behavioral factors. The aim of this study was to measure the quality of screening, prevalence, and susceptibility of viral hepatitis, and to identify barriers to screening in transgender patients undergoing gender identity hormonal therapy. LGBTQ-friendly clinic visits from transgender patients older than 18 years in New York City from 2012 to 2015 were reviewed. Approximately 13% of patients were screened for any viral hepatitis on initial consultation. Screening rates for hepatitis C virus (HCV), hepatitis B virus (HBV), and hepatitis A virus (HAV) at any point were 27, 22, and 20%. HAV screening was performed in 28% of the female to male (FtM) patients and 16% of male to female (MtF) (P<0.05) patients. HBV screening was performed in 30% of FtM patients and 18% of MtF patients (P<0.05). Thirty-one percent of FtM, 24% of MtF, and 17% of genderqueer patients were tested for HCV (P>0.05). Prevalence of HCV, HBV, and HIV in FtM was 0, 0, and 0.44% and that in MtF was 1.78, 0.89, and 1.78%, respectively. Percentage of patients immune to hepatitis A in FtM and MtF subgroups were 55 and 47% (P>0.05). Percentage of patients immune to HBV in FtM and MtF subgroups were 54 and 48% (P>0.05). This study indicates a significant lack of hepatitis screening in the transgender population and a concerning proportion of patients susceptible to disease.
Mirmirani, P; Consolo, M; Oyetakin-White, P; Baron, E; Leahy, P; Karnik, P
2015-06-01
There are regional variations in the scalp hair miniaturization seen in androgenetic alopecia (AGA). Use of topical minoxidil can lead to reversal of miniaturization in the vertex scalp. However, its effects on other scalp regions have been less well studied. To determine whether scalp biopsies from men with AGA show variable gene expression before and after 8 weeks of treatment with minoxidil topical foam 5% (MTF) vs. placebo. A placebo-controlled double-blinded prospective pilot study of MTF vs. placebo was conducted in 16 healthy men aged 18-49 years with Hamilton-Norwood type IV-V thinning. The subjects were asked to apply the treatment (active drug or placebo) to the scalp twice daily for 8 weeks. Stereotactic scalp photographs were taken at the baseline and final visits, to monitor global hair growth. Scalp biopsies were taken at the leading edge of hair loss from the frontal and vertex scalp before and after treatment with MTF and placebo, and microarray analysis was performed using the Affymetrix GeneChip HG U133 Plus 2.0. Global stereotactic photographs showed that MTF induced hair growth in both the frontal and vertex scalp of patients with AGA. Regional differences in gene expression profiles were observed before treatment. However, MTF treatment induced the expression of hair keratin-associated genes and decreased the expression of epidermal differentiation complex and inflammatory genes in both scalp regions. These data suggest that MTF is effective in the treatment of both the frontal and vertex scalp of patients with AGA. © 2014 British Association of Dermatologists.
Study of Plasma Liner Driven Magnetized Target Fusion Via Advanced Simulations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Samulyak, Roman V.; Brookhaven National Lab.; Parks, Paul
The feasibility of the plasma liner driven Magnetized Target Fusion (MTF) via terascale numerical simulations will be assessed. In the MTF concept, a plasma liner, formed by merging of a number (60 or more) of radial, highly supersonic plasma jets, implodes on the target in the form of two compact plasma toroids, and compresses it to conditions of the fusion ignition. By avoiding major difficulties associated with both the traditional laser driven inertial confinement fusion and solid liner driven MTF, the plasma liner driven MTF potentially provides a low-cost and fast R&D path towards the demonstration of practical fusion energy.more » High fidelity numerical simulations of full nonlinear models associated with the plasma liner MTF using state-of-art numerical algorithms and terascale computing are necessary in order to resolve uncertainties and provide guidance for future experiments. At Stony Brook University, we have developed unique computational capabilities that ideally suite the MTF problem. The FronTier code, developed in collaboration with BNL and LANL under DOE funding including SciDAC for the simulation of 3D multi-material hydro and MHD flows, has beenbenchmarked and used for fundamental and engineering problems in energy science applications. We have performed 3D simulations of converging supersonic plasma jets, their merger and the formation of the plasma liner, and a study of the corresponding oblique shock problem. We have studied the implosion of the plasma liner on the magnetized plasma target by resolving Rayleigh-Taylor instabilities in 2D and 3D and other relevant physics and estimate thermodynamic conditions of the target at the moment of maximum compression and the hydrodynamic efficiency of the method.« less
Association study of ERβ, AR, and CYP19A1 genes and MtF transsexualism.
Fernández, Rosa; Esteva, Isabel; Gómez-Gil, Esther; Rumbo, Teresa; Almaraz, Mari Cruz; Roda, Ester; Haro-Mora, Juan-Jesús; Guillamón, Antonio; Pásaro, Eduardo
2014-12-01
The etiology of male-to-female (MtF) transsexualism is unknown. Both genetic and neurological factors may play an important role. To investigate the possible influence of the genetic factor on the etiology of MtF transsexualism. We carried out a cytogenetic and molecular analysis in 442 MtFs and 473 healthy, age- and geographical origin-matched XY control males. The karyotype was investigated by G-banding and by high-density array in the transsexual group. The molecular analysis involved three tandem variable regions of genes estrogen receptor β (ERβ) (CA tandem repeats in intron 5), androgen receptor (AR) (CAG tandem repeats in exon 1), and CYP19A1 (TTTA tandem repeats in intron 4). The allele and genotype frequencies, after division into short and long alleles, were obtained. We investigated the association between genotype and transsexualism by performing a molecular analysis of three variable regions of genes ERβ, AR, and CYP19A1 in 915 individuals (442 MtFs and 473 control males). Most MtFs showed an unremarkable 46,XY karyotype (97.96%). No specific chromosome aberration was associated with MtF transsexualism, and prevalence of aneuploidy (2.04%) was slightly higher than in the general population. Molecular analyses showed no significant difference in allelic or genotypic distribution of the genes examined between MtFs and controls. Moreover, molecular findings presented no evidence of an association between the sex hormone-related genes (ERβ, AR, and CYP19A1) and MtF transsexualism. The study suggests that the analysis of karyotype provides limited information in these subjects. Variable regions analyzed from ERβ, AR, and CYP19A1 are not associated with MtF transsexualism. Nevertheless, this does not exclude other polymorphic regions not analyzed. © 2014 International Society for Sexual Medicine.
NASA Astrophysics Data System (ADS)
Luo, Chun-Ling; Zhuo, Ling-Qing
2017-01-01
Imaging through atmospheric turbulence is a topic with a long history and grand challenges still exist in the remote sensing and astro observation fields. In this letter, we try to propose a simple scheme to improve the resolution of imaging through turbulence based on the computational ghost imaging (CGI) and computational ghost diffraction (CGD) setup via the laser beam shaping techniques. A unified theory of CGI and CGD through turbulence with the multi-Gaussian shaped incoherent source is developed, and numerical examples are given to see clearly the effects of the system parameters to CGI and CGD. Our results show that the atmospheric effect to the CGI and CGD system is closely related to the propagation distance between the source and the object. In addition, by properly increasing the beam order of the multi-Gaussian source, we can improve the resolution of CGI and CGD through turbulence relative to the commonly used Gaussian source. Therefore our results may find applications in remote sensing and astro observation.
Effects of spatial coherence in diffraction phase microscopy.
Edwards, Chris; Bhaduri, Basanta; Nguyen, Tan; Griffin, Benjamin G; Pham, Hoa; Kim, Taewoo; Popescu, Gabriel; Goddard, Lynford L
2014-03-10
Quantitative phase imaging systems using white light illumination can exhibit lower noise figures than laser-based systems. However, they can also suffer from object-dependent artifacts, such as halos, which prevent accurate reconstruction of the surface topography. In this work, we show that white light diffraction phase microscopy using a standard halogen lamp can produce accurate height maps of even the most challenging structures provided that there is proper spatial filtering at: 1) the condenser to ensure adequate spatial coherence and 2) the output Fourier plane to produce a uniform reference beam. We explain that these object-dependent artifacts are a high-pass filtering phenomenon, establish design guidelines to reduce the artifacts, and then apply these guidelines to eliminate the halo effect. Since a spatially incoherent source requires significant spatial filtering, the irradiance is lower and proportionally longer exposure times are needed. To circumvent this tradeoff, we demonstrate that a supercontinuum laser, due to its high radiance, can provide accurate measurements with reduced exposure times, allowing for fast dynamic measurements.
Imaging System Model Crammed Into A 32K Microcomputer
NASA Astrophysics Data System (ADS)
Tyson, Robert K.
1986-12-01
An imaging system model, based upon linear systems theory, has been developed for a microcomputer with less than 32K of free random access memory (RAM). The model includes diffraction effects of the optics, aberrations in the optics, and atmospheric propagation transfer functions. Variables include pupil geometry, magnitude and character of the aberrations, and strength of atmospheric turbulence ("seeing"). Both coherent and incoherent image formation can be evaluated. The techniques employed for crowding the model into a very small computer will be discussed in detail. Simplifying assumptions for the diffraction and aberration phenomena will be shown along with practical considerations in modeling the optical system. Particular emphasis is placed on avoiding inaccuracies in modeling the pupil and the associated optical transfer function knowing limits on spatial frequency content and resolution. Memory and runtime constraints are analyzed stressing the efficient use of assembly language Fourier transform routines, disk input/output, and graphic displays. The compromises between computer time, limited RAM, and scientific accuracy will be given with techniques for balancing these parameters for individual needs.
Imaging quality evaluation method of pixel coupled electro-optical imaging system
NASA Astrophysics Data System (ADS)
He, Xu; Yuan, Li; Jin, Chunqi; Zhang, Xiaohui
2017-09-01
With advancements in high-resolution imaging optical fiber bundle fabrication technology, traditional photoelectric imaging system have become ;flexible; with greatly reduced volume and weight. However, traditional image quality evaluation models are limited by the coupling discrete sampling effect of fiber-optic image bundles and charge-coupled device (CCD) pixels. This limitation substantially complicates the design, optimization, assembly, and evaluation image quality of the coupled discrete sampling imaging system. Based on the transfer process of grayscale cosine distribution optical signal in the fiber-optic image bundle and CCD, a mathematical model of coupled modulation transfer function (coupled-MTF) is established. This model can be used as a basis for following studies on the convergence and periodically oscillating characteristics of the function. We also propose the concept of the average coupled-MTF, which is consistent with the definition of traditional MTF. Based on this concept, the relationships among core distance, core layer radius, and average coupled-MTF are investigated.
Wang, Ling-li; Ren, Wei; Cheng, Qing-feng; Fan, Xiao-dong
2012-09-01
To evaluate the efficacy of metformin (MTF) in treatment of clomiphene (CC)-resistant patients with polycystic ovary syndrome (PCOS). The published articles of randomized controlled trial (RCT) of comparison of MTF combined with CC and CC alone in treatment of CC-resistant PCOS were searched in PubMed, EMBASE, OVID, EBSCO databases and Cochrane Library, and these studies were screened under inclusion and exclusion criteria. The quality of included studies and extract data of comparison of ovulation rates and pregnancy rates were evaluated. And the Meta-analysis using statistic software RevMan 5.0 was completed. Total of 333 patients in total 8 trials were included. Meta analysis showed that MTF plus CC led to a significantly higher clinical ovulation rate (OR = 7.31, 95%CI: 2.57 - 20.76, P < 0.05) and pregnancy rate (OR = 7.93, 95%CI: 2.45 - 25.63, P < 0.05) than that of CC alone. MTF can increase ovulation and pregnancy rates of CC-resistant PCOS women.
NASA Astrophysics Data System (ADS)
Minami, Setsuo; Ogawa, Ryota
1980-09-01
Consequences of the working project formed in JOERA (JAPAN OPTICAL ENGINEERING RESEARCH ASSOCIATION) from 1976 to 1978 are to be reported. The question, "What is the most reasonable number of mesh divides of entrance pupil to get monochromatic OTF and the most economical sampling method of spectral wavelengths to calculate White Light MTF?" is important in the actual stage of designing to optimize the conflict relationship between numerical accuracy and computing time. We have examined the spectral characteristics of OTF using some typical lenses such as photographic telephoto lens and wide angled retrofocus lens, cleared the structure of the White Light MTF, and found some techniques to get the reasonable numerical results. As a result of trial experiments to get coincidence between measurements and calculat-ions, the standard filter, which should be added to the MTF lens tester and whose spectral transmittance should be installed in the calculation, are proposed.
Increased Cortical Thickness in Male-to-Female Transsexualism.
Luders, Eileen; Sánchez, Francisco J; Tosun, Duygu; Shattuck, David W; Gaser, Christian; Vilain, Eric; Toga, Arthur W
2012-08-01
The degree to which one identifies as male or female has a profound impact on one's life. Yet, there is a limited understanding of what contributes to this important characteristic termed gender identity . In order to reveal factors influencing gender identity, studies have focused on people who report strong feelings of being the opposite sex, such as male-to-female (MTF) transsexuals. To investigate potential neuroanatomical variations associated with transsexualism, we compared the regional thickness of the cerebral cortex between 24 MTF transsexuals who had not yet been treated with cross-sex hormones and 24 age-matched control males. Results revealed thicker cortices in MTF transsexuals, both within regions of the left hemisphere (i.e., frontal and orbito-frontal cortex, central sulcus, perisylvian regions, paracentral gyrus) and right hemisphere (i.e., pre-/post-central gyrus, parietal cortex, temporal cortex, precuneus, fusiform, lingual, and orbito-frontal gyrus). These findings provide further evidence that brain anatomy is associated with gender identity, where measures in MTF transsexuals appear to be shifted away from gender-congruent men.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Rong; Lamb, Sherry S.; Zakeri, Bijan
2009-06-01
There is a considerable interest in the modification of existing antibiotics to generate new antimicrobials. Glycopeptide antibiotics (GPAs) are effective against serious Gram-positive bacterial pathogens including methicillin-resistant Staphylococcus aureus. However, resistance to these antibiotics is becoming a serious problem requiring new strategies. We show that the Amycolatopsis orientalis (S)-adenosyl-L-methionine-dependent methyltransferase MtfA, from the vancomycin-class GPA chloroeremomycin biosynthetic pathway, catalyzes in vivo and in vitro methyl transfer to generate methylated GPA derivatives of the teicoplanin class. The crystal structure of MtfA complexed with (S)-adenosyl-L-methionine, (S)-adenosylhomocysteine, or sinefungin inhibitor, coupled with mutagenesis, identified His228 as a likely general base required for methylmore » transfer to the N terminus of the glycopeptide. Computational docking and molecular dynamics simulations were used to model binding of demethyl-vancomycin aglycone to MtfA. These results demonstrate its utility as a tool for engineering methylated analogs of GPAs.« less
NASA Astrophysics Data System (ADS)
Jeon, Hosang; Kim, Hyunduk; Cha, Bo Kyung; Kim, Jong Yul; Cho, Gyuseong; Chung, Yong Hyun; Yun, Jong-Il
2009-06-01
Presently, the gamma camera system is widely used in various medical diagnostic, industrial and environmental fields. Hence, the quantitative and effective evaluation of its imaging performance is essential for design and quality assurance. The National Electrical Manufacturers Association (NEMA) standards for gamma camera evaluation are insufficient to perform sensitive evaluation. In this study, modulation transfer function (MTF) and normalized noise power spectrum (NNPS) will be suggested to evaluate the performance of small gamma camera with changeable pinhole collimators using Monte Carlo simulation. We simulated the system with a cylinder and a disk source, and seven different pinhole collimators from 1- to 4-mm-diameter pinhole with lead. The MTF and NNPS data were obtained from output images and were compared with full-width at half-maximum (FWHM), sensitivity and differential uniformity. In the result, we found that MTF and NNPS are effective and novel standards to evaluate imaging performance of gamma cameras instead of conventional NEMA standards.
NASA Astrophysics Data System (ADS)
Duan, Yaxuan; Xu, Songbo; Yuan, Suochao; Chen, Yongquan; Li, Hongguang; Da, Zhengshang; Gao, Limin
2018-01-01
ISO 12233 slanted-edge method experiences errors using fast Fourier transform (FFT) in the camera modulation transfer function (MTF) measurement due to tilt angle errors in the knife-edge resulting in nonuniform sampling of the edge spread function (ESF). In order to resolve this problem, a modified slanted-edge method using nonuniform fast Fourier transform (NUFFT) for camera MTF measurement is proposed. Theoretical simulations for images with noise at a different nonuniform sampling rate of ESF are performed using the proposed modified slanted-edge method. It is shown that the proposed method successfully eliminates the error due to the nonuniform sampling of the ESF. An experimental setup for camera MTF measurement is established to verify the accuracy of the proposed method. The experiment results show that under different nonuniform sampling rates of ESF, the proposed modified slanted-edge method has improved accuracy for the camera MTF measurement compared to the ISO 12233 slanted-edge method.
Lee, Shinwook; Choi, Myoung; Xu, Zaiwei; Zhao, Zeyu; Alexander, Elsinore; Liu, Yueai
2016-01-01
Purpose The purpose of this study is to compare the optical characteristics of the novel PanOptix presbyopia-correcting trifocal intraocular lens (IOL) and the multifocal ReSTOR +3.0 D IOL, through in vitro bench investigations. Methods The optical characteristics of AcrySof® IQ PanOptix™ (PanOptix) and AcrySof® IQ ReSTOR +3.0 D (ReSTOR +3.0 D) IOLs were evaluated by through-focus Badal images, simulated headlight images, and modulation transfer function (MTF) measurements which determine resolution, photic phenomena, and image quality. Through-focus Badal images of an Early Treatment of Diabetic Retinopathy Study chart were recorded at both photopic and mesopic pupil sizes. Simulated headlight images were taken on an MTF bench with a 50-μm pinhole target and a 5.0 mm pupil at the distance focus of the IOL. MTF curves were measured with a 3.0 mm pupil, and spatial frequencies equivalent to 20/40 and 20/20 visual acuities were recorded to illustrate the through-focus MTF curves. Far-, intermediate-, and near-focus MTF values were obtained. Results Bench Badal image testing and MTF measurements showed that PanOptix has a near focus at a distance of 42 cm and an additional intermediate focus at a distance of about 60 cm. The near focus for ReSTOR +3.0 D is at 45 cm. PanOptix and ReSTOR +3.0 D have comparable photopic distances and near MTF values. Additionally, PanOptix provided a substantial continuous range of vision from distance to intermediate and to near compared with ReSTOR +3.0 D. The halo propensity for PanOptix was slightly higher than that for ReSTOR +3.0 D. Conclusion Laboratory-based in vitro simulations showed that PanOptix trifocal IOL has comparable resolution and image quality performance in distance and near foci compared with ReSTOR +3.0 D IOL. PanOptix showed better resolution and image quality performance at the intermediate focus than ReSTOR +3.0 D IOL. PMID:27330273
Biological indicators for monitoring water quality of MTF canals system
NASA Technical Reports Server (NTRS)
Sethi, S. L.
1975-01-01
Biological models, diversity indexes, were developed to predict environmental effects of NASA's Mississippi test facility (MTF) chemical operations on canal systems in the area. To predict the effects on local streams, a physical model of unpolluted streams was established. The model is fed by artesian well water free of background levels of pollutants. The species diversity and biota composition of unpolluted MTF stream was determined; resulting information will be used to form baseline data for future comparisons. Biological modeling was accomplished by adding controlled quantities or kinds of chemical pollutants and evaluating the effects of these chemicals on the biological life of the stream.
Modulation transfer function measurement technique for small-pixel detectors
NASA Technical Reports Server (NTRS)
Marchywka, Mike; Socker, Dennis G.
1992-01-01
A modulation transfer function (MTF) measurement technique suitable for large-format, small-pixel detector characterization has been investigated. A volume interference grating is used as a test image instead of the bar or sine wave target images normally used. This technique permits a high-contrast, large-area, sinusoidal intensity distribution to illuminate the device being tested, avoiding the need to deconvolve raw data with imaging system characteristics. A high-confidence MTF result at spatial frequencies near 200 cycles/mm is obtained. We present results at several visible light wavelengths with a 6.8-micron-pixel CCD. Pixel response functions are derived from the MTF results.
Reisner, Sari L; Vetters, Ralph; White, Jaclyn M; Cohen, Elijah L; LeClerc, M; Zaslow, Shayne; Wolfrum, Sarah; Mimiaga, Matthew J
2015-01-01
The sexual health of transgender adolescents and young adults who present for health care in urban community health centers is understudied. A retrospective review of electronic health record (EHR) data was conducted from 180 transgender patients aged 12-29 years seen for one or more health-care visits between 2001 and 2010 at an urban community health center serving youth in Boston, MA. Analyses were restricted to 145 sexually active transgender youth (87.3% of the sample). Laboratory-confirmed HIV and sexually transmitted infections (STIs) seroprevalence, demographics, sexual risk behavior, and structural and psychosocial risk indicators were extracted from the EHR. Analyses were descriptively focused for HIV and STIs. Stratified multivariable logistic regression models were fit for male-to-female (MTF) and female-to-male (FTM) patients separately to examine factors associated with any unprotected anal and/or vaginal sex (UAVS). The mean age was 20.0 (SD=2.9); 21.7% people of color, 46.9% white (non-Hispanic), 21.4% race/ethnicity unknown; 43.4% MTF, and 56.6% FTM; and 68.3% were on cross-sex hormones. Prevalence of STIs: 4.8% HIV, 2.8% herpes simplex virus, 2.8% syphilis, 2.1% chlamydia, 2.1% gonorrhea, 2.8% hepatitis C, 1.4% human papilloma virus. Only gonorrhea prevalence significantly differed by gender identity (MTF 2.1% vs. 0.0% FTM; p=0.046). Nearly half (47.6%) of the sample engaged in UAVS (52.4% MTF, 43.9% FTM, p=0.311). FTM more frequently had a primary sex partner compared to MTF (48.8% vs. 25.4%; p=0.004); MTF more frequently had a casual sex partner than FTM (69.8% vs. 42.7% p=0.001). In multivariable models, MTF youth who were younger in age, white non-Hispanic, and reported a primary sex partner had increased odds of UAVS; whereas, FTM youth reporting a casual sex partner and current alcohol use had increased odds of UAVS (all p<0.05). Factors associated with sexual risk differ for MTF and FTM youth. Partner type appears pivotal to understanding sexual risk in transgender adolescents and young adults. HIV and STI prevention efforts, including early intervention efforts, are needed in community-based settings serving transgender youth that attend to sex-specific (biological) and gender-related (social) pathways.
Sociodemographic Study of Danish Individuals Diagnosed with Transsexualism
Simonsen, Rikke; Hald, Gert Martin; Giraldi, Annamaria; Kristensen, Ellids
2015-01-01
Introduction Male-to-female (MtF) and female-to-male (FtM) individuals with transsexualism (International Classification of Diseases-10) may differ in core clinical and sociodemographic variables such as age, sexual orientation, marriage and parenthood, school, educational level, and employment. Assessing and understanding the implication of such differences may be a key to developing appropriate and effective treatment and intervention strategies for this group. However, research in the area remains sparse and is often on small populations, making the generalization of results from current studies on individuals diagnosed with transsexualism difficult. Aims (i) To describe and assess key sociodemographic and treatment-related differences between MtF and FtM individuals in a Danish population of individuals diagnosed with transsexualism; (ii) to assess possible implications of such difference, if any, for clinical treatment initiatives for individuals diagnosed with transsexualism. Methods Follow-up of 108 individuals who had permission to undergo sex reassignment surgery (SRS, meaning castration and genital plastic surgery) over a 30-year period from 1978 to 2008 through the Gender Identity Unit in Copenhagen, Denmark. The individuals were identified through Social Security numbers. Clinical and sociodemographic data from medical records were collected. Results The sex ratio was 1.16:1 (MtF : FtM). Mean age at first referral was 26.9 (standard deviation [SD] 8.8) years for FtM and 30.2 (SD 9.7) for MtF individuals. Compared with MtF, FtM had a significantly lower onset age (before 12 years of age) and lower age when permission for SRS was granted. Further, FtM individuals were significantly more often gynephilic (sexually attracted to females) during research period and less likely to start self-initiated hormonal sex reassignment (SR) (treatment with cross-sex hormones). The MtF and FtM groups did not differ in years of school, educational level, employment, or engagement in marriage and cohabitation. Conclusions As approximately half of MtF started cross-sex hormonal SR without attending a gender unit, future treatment needs to focus on this group of MtF individuals in order to accommodate the medical risks of self-initiated hormonal treatment.Earlier intervention with adolescents appears necessary since three-quarters of FtM individuals before age 12 had problems with their assigned sex. For both MtF and FtM, we found problems in areas of school, education, and employment and recommend further help in these core areas. PMID:26185676
Stress-coping strategies of patients with gender identity disorder.
Matsumoto, Yosuke; Sato, Toshiki; Ohnishi, Masaru; Kishimoto, Yuki; Terada, Seishi; Kuroda, Shigetoshi
2009-12-01
Previous research has not addressed gender differences in coping strategies among patients with gender identity disorder (GID). Nor has the relationship of coping strategies to other demographic characteristics ever been clarified in GID. In this study, we tried to clarify the relationship between stress-coping strategies and demographic characteristics among patients with GID. The coping strategies of 344 patients with GID [227 female-to-male (FTM) and 117 male-to-female (MTF)] were assessed using the Japanese version of the Ways of Coping Questionnaires, Lazarus Stress-coping Inventory. Comparison of the stress-coping inventory between MTF and FTM GID patients revealed that FTM GID patients were significantly more reliant on positive reappraisal strategies in stressful situations than MTF GID patients (P = 0.007). The difference in the usage of positive reappraisal strategies between MTF and FTM type GID patients was not explained by other demographic characteristics, and we suppose that the gender difference in GID patients might influence the usage of positive reappraisal strategies. The ratio of FTM GID patients might be higher at our center because MTF GID patients can obtain vaginoplasty easily, whereas phalloplasty surgery for FTM GID patients is performed at only a few centers, including our clinic, in Japan. As a result, more FTM GID patients come to our clinic with a clear intention to undergo sexual rearrangement surgery, which might influence the gender difference in using positive reappraisal.
A hyperspectral image optimizing method based on sub-pixel MTF analysis
NASA Astrophysics Data System (ADS)
Wang, Yun; Li, Kai; Wang, Jinqiang; Zhu, Yajie
2015-04-01
Hyperspectral imaging is used to collect tens or hundreds of images continuously divided across electromagnetic spectrum so that the details under different wavelengths could be represented. A popular hyperspectral imaging methods uses a tunable optical band-pass filter settled in front of the focal plane to acquire images of different wavelengths. In order to alleviate the influence of chromatic aberration in some segments in a hyperspectral series, in this paper, a hyperspectral optimizing method uses sub-pixel MTF to evaluate image blurring quality was provided. This method acquired the edge feature in the target window by means of the line spread function (LSF) to calculate the reliable position of the edge feature, then the evaluation grid in each line was interpolated by the real pixel value based on its relative position to the optimal edge and the sub-pixel MTF was used to analyze the image in frequency domain, by which MTF calculation dimension was increased. The sub-pixel MTF evaluation was reliable, since no image rotation and pixel value estimation was needed, and no artificial information was introduced. With theoretical analysis, the method proposed in this paper is reliable and efficient when evaluation the common images with edges of small tilt angle in real scene. It also provided a direction for the following hyperspectral image blurring evaluation and the real-time focal plane adjustment in real time in related imaging system.
NASA Astrophysics Data System (ADS)
Wu, Z.; Luo, Z.; Zhang, Y.; Guo, F.; He, L.
2018-04-01
A Modulation Transfer Function (MTF)-based fuzzy comprehensive evaluation method was proposed in this paper for the purpose of evaluating high-resolution satellite image quality. To establish the factor set, two MTF features and seven radiant features were extracted from the knife-edge region of image patch, which included Nyquist, MTF0.5, entropy, peak signal to noise ratio (PSNR), average difference, edge intensity, average gradient, contrast and ground spatial distance (GSD). After analyzing the statistical distribution of above features, a fuzzy evaluation threshold table and fuzzy evaluation membership functions was established. The experiments for comprehensive quality assessment of different natural and artificial objects was done with GF2 image patches. The results showed that the calibration field image has the highest quality scores. The water image has closest image quality to the calibration field, quality of building image is a little poor than water image, but much higher than farmland image. In order to test the influence of different features on quality evaluation, the experiment with different weights were tested on GF2 and SPOT7 images. The results showed that different weights correspond different evaluating effectiveness. In the case of setting up the weights of edge features and GSD, the image quality of GF2 is better than SPOT7. However, when setting MTF and PSNR as main factor, the image quality of SPOT7 is better than GF2.
NASA Astrophysics Data System (ADS)
Chubar, O.
2006-09-01
The paper describes methods of efficient calculation of spontaneous synchrotron radiation (SR) by relativistic electrons in storage rings, and propagation of this radiation through optical elements and drift spaces of beamlines, using the principles of wave optics. In addition to the SR from one electron, incoherent and coherent synchrotron radiation (CSR) emitted by electron bunches is treated. CPU-efficient CSR calculation method taking into account 6D phase space distribution of electrons in a bunch is proposed. The properties of CSR emitted by electron bunches with small longitudinal and large transverse size are studied numerically (such situation can be realized in storage rings e.g. by transverse deflection of the electron bunches in special RF cavities). It is shown that if the transverse size of a bunch is much larger than the diffraction limit for single-electron SR at a given wavelength - it affects the angular distribution of the CSR at this wavelength and reduces the coherent flux. Nevertheless, for transverse bunch dimensions up to several millimeters and the longitudinal bunch size smaller than hundred micrometers, the resulting CSR flux in the far infrared spectral range is still many orders of magnitude higher than the flux of incoherent SR.
Ferritic Alloys with Extreme Creep Resistance via Coherent Hierarchical Precipitates
Song, Gian; Sun, Zhiqian; Li, Lin; Xu, Xiandong; Rawlings, Michael; Liebscher, Christian H.; Clausen, Bjørn; Poplawsky, Jonathan; Leonard, Donovan N.; Huang, Shenyan; Teng, Zhenke; Liu, Chain T.; Asta, Mark D.; Gao, Yanfei; Dunand, David C.; Ghosh, Gautam; Chen, Mingwei; Fine, Morris E.; Liaw, Peter K.
2015-01-01
There have been numerous efforts to develop creep-resistant materials strengthened by incoherent particles at high temperatures and stresses in response to future energy needs for steam turbines in thermal-power plants. However, the microstructural instability of the incoherent-particle-strengthened ferritic steels limits their application to temperatures below 900 K. Here, we report a novel ferritic alloy with the excellent creep resistance enhanced by coherent hierarchical precipitates, using the integrated experimental (transmission-electron microscopy/scanning-transmission-electron microscopy, in-situ neutron diffraction, and atom-probe tomography) and theoretical (crystal-plasticity finite-element modeling) approaches. This alloy is strengthened by nano-scaled L21-Ni2TiAl (Heusler phase)-based precipitates, which themselves contain coherent nano-scaled B2 zones. These coherent hierarchical precipitates are uniformly distributed within the Fe matrix. Our hierarchical structure material exhibits the superior creep resistance at 973 K in terms of the minimal creep rate, which is four orders of magnitude lower than that of conventional ferritic steels. These results provide a new alloy-design strategy using the novel concept of hierarchical precipitates and the fundamental science for developing creep-resistant ferritic alloys. The present research will broaden the applications of ferritic alloys to higher temperatures. PMID:26548303
Ferritic Alloys with Extreme Creep Resistance via Coherent Hierarchical Precipitates
Song, Gian; Sun, Zhiqian; Li, Lin; ...
2015-11-09
There have been numerous efforts to develop creep-resistant materials strengthened by incoherent particles at high temperatures and stresses in response to future energy needs for steam turbines in thermal-power plants. However, the microstructural instability of the incoherent-particle-strengthened ferritic steels limits their application to temperatures below 900 K. Here, we report a novel ferritic alloy with the excellent creep resistance enhanced by coherent hierarchical precipitates, using the integrated experimental (transmission-electron microscopy/scanning-transmission-electron microscopy, in-situ neutron diffraction, and atom-probe tomography) and theoretical (crystal-plasticity finite-element modeling) approaches. This alloy is strengthened by nano-scaled L21-Ni2TiAl (Heusler phase)-based precipitates, which themselves contain coherent nano-scaled B2 zones.more » These coherent hierarchical precipitates are uniformly distributed within the Fe matrix. Our hierarchical structure material exhibits the superior creep resistance at 973 K in terms of the minimal creep rate, which is four orders of magnitude lower than that of conventional ferritic steels. These results provide a new alloy-design strategy using the novel concept of hierarchical precipitates and the fundamental science for developing creep-resistant ferritic alloys. Finally, the present research will broaden the applications of ferritic alloys to higher temperatures.« less
Dynamics of crystalline acetanilide: Analysis using neutron scattering and computer simulation
NASA Astrophysics Data System (ADS)
Hayward, R. L.; Middendorf, H. D.; Wanderlingh, U.; Smith, J. C.
1995-04-01
The unusual temperature dependence of several optical spectroscopic vibrational bands in crystalline acetanilide has been interpreted as providing evidence for dynamic localization. Here we examine the vibrational dynamics of crystalline acetanilide over a spectral range of ˜20-4000 cm-1 using incoherent neutron scattering experiments, phonon normal mode calculations and molecular dynamics simulations. A molecular mechanics energy function is parametrized and used to perform the normal mode analyses in the full configurational space of the crystal i.e., including the intramolecular and intermolecular degrees of freedom. One- and multiphonon incoherent inelastic neutron scattering intensities are calculated from harmonic analyses in the first Brillouin zone and compared with the experimental data presented here. Phonon dispersion relations and mean-square atomic displacements are derived from the harmonic model and compared with data derived from coherent inelastic neutron scattering and neutron and x-ray diffraction. To examine the temperature effects on the vibrations the full, anharmonic potential function is used in molecular dynamics simulations of the crystal at 80, 140, and 300 K. Several, but not all, of the spectral features calculated from the molecular dynamics simulations exhibit temperature-dependent behavior in agreement with experiment. The significance of the results for the interpretation of the optical spectroscopic results and possible improvements to the model are discussed.
Improved wavefront correction for coherent image restoration.
Zelenka, Claudius; Koch, Reinhard
2017-08-07
Coherent imaging has a wide range of applications in, for example, microscopy, astronomy, and radar imaging. Particularly interesting is the field of microscopy, where the optical quality of the lens is the main limiting factor. In this article, novel algorithms for the restoration of blurred images in a system with known optical aberrations are presented. Physically motivated by the scalar diffraction theory, the new algorithms are based on Haugazeau POCS and FISTA, and are faster and more robust than methods presented earlier. With the new approach the level of restoration quality on real images is very high, thereby blurring and ringing caused by defocus can be effectively removed. In classical microscopy, lenses with very low aberration must be used, which puts a practical limit on their size and numerical aperture. A coherent microscope using the novel restoration method overcomes this limitation. In contrast to incoherent microscopy, severe optical aberrations including defocus can be removed, hence the requirements on the quality of the optics are lower. This can be exploited for an essential price reduction of the optical system. It can be also used to achieve higher resolution than in classical microscopy, using lenses with high numerical aperture and high aberration. All this makes the coherent microscopy superior to the traditional incoherent in suited applications.
Brooker, Gary; Siegel, Nisan; Rosen, Joseph; Hashimoto, Nobuyuki; Kurihara, Makoto; Tanabe, Ayano
2013-12-15
We report a new optical arrangement that creates high-efficiency, high-quality Fresnel incoherent correlation holography (FINCH) holograms using polarization sensitive transmission liquid crystal gradient index (TLCGRIN) diffractive lenses. In contrast, current universal practice in the field employs a reflective spatial light modulator (SLM) to separate sample and reference beams. Polarization sensitive TLCGRIN lenses enable a straight optical path, have >90% transmission efficiency, are not pixilated, and are free of many limitations of reflective SLM devices. For each sample point, two spherical beams created by a glass lens in combination with a polarization sensitive TLCGRIN lens interfere and create a hologram and resultant super resolution image.
NASA Technical Reports Server (NTRS)
Beratan, David N. (Inventor); Perry, Joseph W. (Inventor)
1991-01-01
A single material (not a multi-element structure) spatial light modulator may be written to, as well as read out from, using light. The device has tailorable rise and hold times dependent on the composition and concentration of the molecular species used as the active components. The spatial resolution of this device is limited only by light diffraction as in volume holograms. The device may function as a two-dimensional mask (transmission or reflection) or as a three-dimensional volume holographic medium. This device, based on optically-induced electron transfer, is able to perform incoherent to coherent image conversion or wavelength conversion over a wide spectral range (ultraviolet, visible, or near-infrared regions).
Siegel, Nisan; Rosen, Joseph; Brooker, Gary
2013-10-01
Recent advances in Fresnel incoherent correlation holography (FINCH) increase the signal-to-noise ratio in hologram recording by interference of images from two diffractive lenses with focal lengths close to the image plane. Holograms requiring short reconstruction distances are created that reconstruct poorly with existing Fresnel propagation methods. Here we show a dramatic improvement in reconstructed fluorescent images when a 2D Hamming window function substituted for the disk window typically used to bound the impulse response in the Fresnel propagation. Greatly improved image contrast and quality are shown for simulated and experimentally determined FINCH holograms using a 2D Hamming window without significant loss in lateral or axial resolution.
NASA Astrophysics Data System (ADS)
Cindrich, Ivan
1988-01-01
The present conference discusses topics in design and analysis methods for holographic optics, as well as their materials and fabrication techniques and their applications. Attention is given to novel holographic helmet display designs, holographic optics optimization by damped least-squares and wavefront matching, the optical performance of holographic kinoforms, a cascaded transmission hologram for HUDs, a multilayer thin film simulation of volume holograms, and the DMP-128 holographic-recording photopolymer. Also discussed are a uniform hologram construction layout, diffractive optics with incoherent optical systems, holographic laser-protective eyewear, novel applications for embossed holograms, and hologon deflectors with dispersive optical elements for scan line bow correction.
Elastic scattering losses from colliding Bose-Einstein condensates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zin Pawel; Chwedenczuk, Jan; Trippenbach, Marek
2006-03-15
Bragg diffraction divides a Bose-Einstein condensate into two overlapping components, moving with respect to each other with high momentum. Elastic collisions between atoms from distinct wave packets can significantly deplete the condensate. Recently, Zin et al. [Phys. Rev. Lett. 94, 200401 (2005)] introduced a model of two counterpropagating atomic Gaussian wave packets incorporating the dynamics of the incoherent scattering processes. Here we study the properties of this model in detail, including the nature of the transition from spontaneous to stimulated scattering. Within the first-order approximation, we derive analytical expressions for the density matrix and anomalous density that provide excellent insightmore » into correlation properties of scattered atoms.« less
Plasma Liner Research for MTF at NASA Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
Thio, Y. C. F.; Eskridge, R.; Lee, M.; Martin, A.; Smith, J.; Cassibry, J. T.; Wu, S. T.; Kirkpatrick, R. C.; Knapp, C. E.; Turchi, P. J.;
2002-01-01
The current research effort at NASA Marshall Space Flight Center (MSFC) in MTF is directed towards exploring the critical physics issues of potential embodiments of MTF for propulsion, especially standoff drivers involving plasma liners for MTF. There are several possible approaches for forming plasma liners. One approach consists of using a spherical array of plasma jets to form a spherical plasma shell imploding towards the center of a magnetized plasma, a compact toroid. Current experimental plan and status to explore the physics of forming a 2-D plasma liner (shell) by merging plasma jets are described. A first-generation coaxial plasma guns (Mark-1) to launch the required plasma jets have been built and tested. Plasma jets have been launched reproducibly with a low jitter, and velocities in excess of 50 km/s for the leading edge of the plasma jet. Some further refinements are being explored for the plasma gun, Successful completion of these single-gun tests will be followed by an experimental exploration of the problems of launching a multiple number of these jets simultaneously to form a cylindrical plasma liner.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yashchuk, V.V.; Takacs, P.; Anderson, E.H.
A modulation transfer function (MTF) calibration method based on binary pseudorandom (BPR) gratings and arrays has been proven to be an effective MTF calibration method for interferometric microscopes and a scatterometer. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 in. phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending andmore » filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to the BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.« less
Increased Cortical Thickness in Male-to-Female Transsexualism
Luders, Eileen; Sánchez, Francisco J.; Tosun, Duygu; Shattuck, David W.; Gaser, Christian; Vilain, Eric; Toga, Arthur W.
2013-01-01
Background The degree to which one identifies as male or female has a profound impact on one’s life. Yet, there is a limited understanding of what contributes to this important characteristic termed gender identity. In order to reveal factors influencing gender identity, studies have focused on people who report strong feelings of being the opposite sex, such as male-to-female (MTF) transsexuals. Method To investigate potential neuroanatomical variations associated with transsexualism, we compared the regional thickness of the cerebral cortex between 24 MTF transsexuals who had not yet been treated with cross-sex hormones and 24 age-matched control males. Results Results revealed thicker cortices in MTF transsexuals, both within regions of the left hemisphere (i.e., frontal and orbito-frontal cortex, central sulcus, perisylvian regions, paracentral gyrus) and right hemisphere (i.e., pre-/post-central gyrus, parietal cortex, temporal cortex, precuneus, fusiform, lingual, and orbito-frontal gyrus). Conclusion These findings provide further evidence that brain anatomy is associated with gender identity, where measures in MTF transsexuals appear to be shifted away from gender-congruent men. PMID:23724358
NASA Astrophysics Data System (ADS)
Newswander, T.; Riesland, David W.; Miles, Duane; Reinhart, Lennon
2017-09-01
For space optical systems that image extended scenes such as earth-viewing systems, modulation transfer function (MTF) test data is directly applicable to system optical resolution. For many missions, it is the most direct metric for establishing the best focus of the instrument. Additionally, MTF test products can be combined to predict overall imaging performance. For fixed focus instruments, finding the best focus during ground testing is critical to achieving good imaging performance. The ground testing should account for the full-imaging system, operational parameters, and operational environment. Testing the full-imaging system removes uncertainty caused by breaking configurations and the combination of multiple subassembly test results. For earth viewing, the imaging system needs to be tested at infinite conjugate. Operational environment test conditions should include temperature and vacuum. Optical MTF testing in the presence of operational vibration and gravity release is less straightforward and may not be possible on the ground. Gravity effects are mitigated by testing in multiple orientations. Many space telescope systems are designed and built to have optimum performance in a gravity-free environment. These systems can have imaging performance that is dominated by aberration including astigmatism. This paper discusses how the slanted edge MTF test is applied to determine the best focus of a space optical telescope in ground testing accounting for gravity sag effects. Actual optical system test results and conclusions are presented.
Effects of image processing on the detective quantum efficiency
NASA Astrophysics Data System (ADS)
Park, Hye-Suk; Kim, Hee-Joung; Cho, Hyo-Min; Lee, Chang-Lae; Lee, Seung-Wan; Choi, Yu-Na
2010-04-01
Digital radiography has gained popularity in many areas of clinical practice. This transition brings interest in advancing the methodologies for image quality characterization. However, as the methodologies for such characterizations have not been standardized, the results of these studies cannot be directly compared. The primary objective of this study was to standardize methodologies for image quality characterization. The secondary objective was to evaluate affected factors to Modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) according to image processing algorithm. Image performance parameters such as MTF, NPS, and DQE were evaluated using the international electro-technical commission (IEC 62220-1)-defined RQA5 radiographic techniques. Computed radiography (CR) images of hand posterior-anterior (PA) for measuring signal to noise ratio (SNR), slit image for measuring MTF, white image for measuring NPS were obtained and various Multi-Scale Image Contrast Amplification (MUSICA) parameters were applied to each of acquired images. In results, all of modified images were considerably influence on evaluating SNR, MTF, NPS, and DQE. Modified images by the post-processing had higher DQE than the MUSICA=0 image. This suggests that MUSICA values, as a post-processing, have an affect on the image when it is evaluating for image quality. In conclusion, the control parameters of image processing could be accounted for evaluating characterization of image quality in same way. The results of this study could be guided as a baseline to evaluate imaging systems and their imaging characteristics by measuring MTF, NPS, and DQE.
Mirmirani, P.; Consolo, M.; Oyetakin-White, P.; Baron, E.; Leahy, P.; Karnik, P.
2014-01-01
Summary Background There are regional variations in scalp hair miniaturization seen in androgenetic alopecia (AGA). Use of topical minoxidil can lead to reversal of miniaturization in the vertex scalp. However, its effects on other scalp regions are less well studied. Methods A placebo controlled double-blinded prospective pilot study of minoxidil topical foam 5% (MTF) vs placebo was conducted in sixteen healthy men ages 18-49 with Hamilton-Norwood type IV-V thinning. The subjects were asked to apply the treatment (active drug or placebo) to the scalp twice daily for eight weeks. Stereotactic scalp photographs were taken at the baseline and final visits to monitor global hair growth. Scalp biopsies were done at the leading edge of hair loss from the frontal and vertex scalp before and after treatment with MTF and placebo and microarray analysis was done using the Affymetrix GeneChip HG U133 Plus 2.0. Results Global stereotactic photographs showed that MTF induced hair growth in both the frontal and vertex scalp of AGA patients. Regional differences in gene expression profiles were observed before treatment. However, MTF treatment induced the expression of hair keratin associated genes and decreased the expression of epidermal differentiation complex (EDC) and inflammatory genes in both scalp regions. Conclusions These data suggest that MTF is effective in the treatment of both the frontal and vertex scalp of AGA patients. PMID:25204361
Adams, Scott V.; Barrick, Brian; Freney, Emily P.; Shafer, Martin M.; Makar, Karen; Song, Xiaoling; Lampe, Johanna; Vilchis, Hugo; Ulery, April; Newcomb, Polly A.
2015-01-01
Background Metallothionein (MT) proteins play critical roles in the physiological handling of both essential (Cu and Zn) and toxic (Cd) metals. MT expression is regulated by metal-regulatory transcription factor 1 (MTF1). Hence, genetic variation in the MT gene family and MTF1 might therefore influence excretion of these metals. Methods 321 women were recruited in Seattle, WA and Las Cruces, NM and provided demographic information, urine samples for measurement of metal concentrations by mass spectrometry and creatinine, and blood or saliva for extraction of DNA. Forty-one single nucleotide polymorphisms (SNPs) within the MTF1 gene region and the region of chromosome 16 encoding the MT gene family were selected for genotyping in addition to an ancestry informative marker panel. Linear regression was used to estimate the association of SNPs with urinary Cd, Cu, and Zn, adjusted for age, urinary creatinine, smoking history, study site, and ancestry. Results Minor alleles of rs28366003 and rs10636 near the MT2A gene were associated with lower urinary Cd, Cu, and Zn. Minor alleles of rs8044719 and rs1599823, near MT1A and MT1B, were associated with lower urinary Cd and Zn, respectively. Minor alleles of rs4653329 in MTF1 was associated with lower urinary Cd. Conclusions These results suggest that genetic variation in the MT gene region and MTF1 influences urinary Cd, Cu, and Zn excretion. PMID:26529669
MTF measurement of IR optics in different temperature ranges
NASA Astrophysics Data System (ADS)
Bai, Alexander; Duncker, Hannes; Dumitrescu, Eugen
2017-10-01
Infrared (IR) optical systems are at the core of many military, civilian and manufacturing applications and perform mission critical functions. To reliably fulfill the demanding requirements imposed on today's high performance IR optics, highly accurate, reproducible and fast lens testing is of crucial importance. Testing the optical performance within different temperature ranges becomes key in many military applications. Due to highly complex IR-Applications in the fields of aerospace, military and automotive industries, MTF Measurement under realistic environmental conditions become more and more relevant. A Modulation Transfer Function (MTF) test bench with an integrated thermal chamber allows measuring several sample sizes in a temperature range from -40 °C to +120°C. To reach reliable measurement results under these difficult conditions, a specially developed temperature stable design including an insulating vacuum are used. The main function of this instrument is the measurement of the MTF both on- and off-axis at up to +/-70° field angle, as well as measurement of effective focal length, flange focal length and distortion. The vertical configuration of the system guarantees a small overall footprint. By integrating a high-resolution IR camera with focal plane array (FPA) in the detection unit, time consuming measurement procedures such as scanning slit with liquid nitrogen cooled detectors can be avoided. The specified absolute accuracy of +/- 3% MTF is validated using internationally traceable reference optics. Together with a complete and intuitive software solution, this makes the instrument a turn-key device for today's state-of- the-art optical testing.
Image quality of the cat eye measured during retinal ganglion cell experiments.
Bonds, A B; Enroth-Cugell, C; Pinto, L H
1972-01-01
1. The modulation transfer function (MTF) of the dioptrics of fifteen cat eyes was determined. The aerial image, formed by the eye of a standard object (a 0.5-1.0 degrees annulus), was photographed. The transmission of the film negative was measured with a scanning microdensitometer to yield the light distribution within the aerial image. Correcting for the double passage, this experimentally determined light distribution and the known object light distribution were used to obtain the MTF, applying Fourier methods. Each MTF was used to calculate the light distribution within the retinal image of stimuli of various geometry used in experiments on retinal ganglion cells in the same eye.2. When the eye was equipped with an artificial pupil of the same size as that used in the neurophysiological experiments (4.0-4.8 mm diam.) the MTF had fallen to 0.5 at 2.43 c/deg. When the pupil was removed the MTF had fallen to 0.5 at a much lower spatial frequency (1.0 c/deg). This shows that even when one uses an artificial pupil too large to provide optimal image quality there is a vast improvement over using no pupil.3. These image quality measurements were prompted by the need to know the actual stimulus image in experiments on the functional organization of the receptive field, a need exemplified in this paper by a few specific physiological results. The full neurophysiological results appear in the next two papers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, X.; Hua, H.; Balamurugan, K.
2009-05-12
Drosophila melanogaster MTF-1 (dMTF-1) is a copper-responsive transcriptional activator that mediates resistance to Cu, as well as Zn and Cd. Here, we characterize a novel cysteine-rich domain which is crucial for sensing excess intracellular copper by dMTF-1. Transgenic flies expressing mutant dMTF-1 containing alanine substitutions of two, four or six cysteine residues within the sequence {sup 547}CNCTNCKCDQTKSCHGGDC{sup 565} are significantly or completely impaired in their ability to protect flies from copper toxicity and fail to up-regulate MtnA (metallothionein) expression in response to excess Cu. In contrast, these flies exhibit wild-type survival in response to copper deprivation thus revealing that themore » cysteine cluster domain is required only for sensing Cu load by dMTF-1. Parallel studies show that the isolated cysteine cluster domain is required to protect a copper-sensitive S. cerevisiae ace1 strain from copper toxicity. Cu(I) ligation by a Cys-rich domain peptide fragment drives the cooperative assembly of a polydentate [Cu{sub 4}-S{sub 6}] cage structure, characterized by a core of trigonally S{sub 3} coordinated Cu(I) ions bound by bridging thiolate ligands. While reminiscent of Cu{sub 4}-L{sub 6} (L = ligand) tetranuclear clusters in copper regulatory transcription factors of yeast, the absence of significant sequence homology is consistent with convergent evolution of a sensing strategy particularly well suited for Cu(I).« less
Wooten, Dennis C; Starr, Clarise R; Lyon, Wanda J
2016-01-01
Different forms of heavy metals affect biochemical systems in characteristic ways that cannot be detected with typical metal analysis methods like atomic absorption spectrometry. Further, using living systems to analyze interaction of heavy metals with biochemical systems can be laborious and unreliable. To generate a reliable easy-to-use biologically-based biosensor system, the entire human metallothionein-II (MT-II) gene was incorporated into a plasmid (pUC57-MT) easily replicated in Escherichia coli. In this system, a commercial polyclonal antibody raised against human metal-responsive transcription factor-1 protein (MTF-1 protein) could modify the electrophoretic migration patterns (i.e. cause specific decreases in agarose gel electrophoretic mobility) of the plasmid in the presence or absence of heavy metals other than zinc (Zn). In the study here, heavy metals, MTF-1 protein, and polyclonal anti-MTF-1 antibody were used to assess pUC57-MT plasmid antibody-assisted electrophoretic mobility. Anti-MTF-1 antibody bound both MTF-1 protein and pUC57-MT plasmid in a non-competitive fashion such that it could be used to differentiate specific heavy metal binding. The results showed that antibody-inhibited plasmid migration was heavy metal level-dependent. Zinc caused a unique mobility shift pattern opposite to that of other metals tested, i.e. Zn blocked the antibody ability to inhibit plasmid migration, despite a greatly increased affinity for DNA by the antibody when Zn was present. The Zn effect was reversed/modified by adding MTF-1 protein. Additionally, antibody inhibition of plasmid mobility was resistant to heat pre-treatment and trypsinization, indicating absence of residual DNA extraction-resistant bacterial DNA binding proteins. DNA binding by anti-DNA antibodies may be commonly enhanced by xenobiotic heavy metals and elevated levels of Zn, thus making them potentially effective tools for assessment of heavy metal bioavailability in aqueous solutions and fluid obtained from metal implant sites.
Contributions to the Characterization and Mitigation of Rotorcraft Brownout
NASA Astrophysics Data System (ADS)
Tritschler, John Kirwin
Rotorcraft brownout, the condition in which the flow field of a rotorcraft mobilizes sediment from the ground to generate a cloud that obscures the pilot's field of view, continues to be a significant hazard to civil and military rotorcraft operations. This dissertation presents methodologies for: (i) the systematic mitigation of rotorcraft brownout through operational and design strategies and (ii) the quantitative characterization of the visual degradation caused by a brownout cloud. In Part I of the dissertation, brownout mitigation strategies are developed through simulation-based brownout studies that are mathematically formulated within a numerical optimization framework. Two optimization studies are presented. The first study involves the determination of approach-to-landing maneuvers that result in reduced brownout severity. The second study presents a potential methodology for the design of helicopter rotors with improved brownout characteristics. The results of both studies indicate that the fundamental mechanisms underlying brownout mitigation are aerodynamic in nature, and the evolution of a ground vortex ahead of the rotor disk is seen to be a key element in the development of a brownout cloud. In Part II of the dissertation, brownout cloud characterizations are based upon the Modulation Transfer Function (MTF), a metric commonly used in the optics community for the characterization of imaging systems. The use of the MTF in experimentation is examined first, and the application of MTF calculation and interpretation methods to actual flight test data is described. The potential for predicting the MTF from numerical simulations is examined second, and an initial methodology is presented for the prediction of the MTF of a brownout cloud. Results from the experimental and analytical studies rigorously quantify the intuitively-known facts that the visual degradation caused by brownout is a space and time-dependent phenomenon, and that high spatial frequency features, i.e., fine-grained detail, are obscured before low spatial frequency features, i.e., large objects. As such, the MTF is a metric that is amenable to Handling Qualities (HQ) analyses.
Blume-Peytavi, Ulrike; Hillmann, Kathrin; Dietz, Ekkehart; Canfield, Douglas; Garcia Bartels, Natalie
2011-12-01
Although twice-daily application of propylene glycol-containing 2% minoxidil topical solution (MTS) stimulates new hair growth, higher concentrations of minoxidil in a once-daily, propylene glycol-free formulation may improve efficacy and reduce unpleasant side effects. We sought to compare the efficacy, safety, and acceptability and to show noninferiority of once-daily 5% minoxidil topical foam (MTF) with twice-daily 2% MTS in women with androgenetic alopecia. A total of 113 women with androgenetic alopecia were randomized to 24 weeks of treatment with 5% MTF or 2% MTS. The primary efficacy parameter was change from baseline in nonvellus target area hair count at week 24. Secondary end points included change in nonvellus target area hair width, overall efficacy by global photographic review as assessed by treatment-blinded evaluators and the subject herself, adverse events, and participants' assessment of product aesthetics. After 24 weeks, women randomized to 5% MTF once daily showed noninferior target area hair count and target area hair width and experienced greater, but nonsignificant, improvements in target area hair count, target area hair width, and overall efficacy by global photographic review than those randomized to 2% MTS used twice daily. 5% MTF was significantly superior to 2% MTS in participants' agreement with "the treatment does not interfere with styling my hair" (P = .002). Women randomized to 5% MTF experienced significantly lower rates of local intolerance (P = .046) especially in pruritus and dandruff compared with 2% MTS. Because of differences in the formulations tested, study participants were not blinded to treatment. Once-daily 5% MTF is noninferior and as effective for stimulating hair growth as twice-daily 2% MTS in women with androgenetic alopecia and is associated with several aesthetic and practical advantages. Copyright © 2010 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tokurei, S; Department of Radiology, Yamaguchi University Hospital, Ube, Yamaguchi; Morishita, J
2015-06-15
Purpose: To develop a method for improving sharpness of images reproduced on liquid-crystal displays (LCDs) by compensating for the degradation of modulation transfer function (MTF) of the LCD. Methods: The inherent MTF of a color LCD (display MTF) was measured using a commercially available color digital camera. The frequency responses necessary to compensate for the resolution property of the LCD were calculated from the inverses of the display MTFs in both the horizontal and vertical directions. In addition, the inverses of the display MTFs were combined with the response of the human eye. The finite impulse response (FIR) filters weremore » computed by taking the inverse Fourier transform of the frequency responses, and the effects of the FIR filtering on both the resolution and noise properties of the displayed images were verified by measuring the MTF and Wiener spectrum (WS), respectively. The FIR filtering was then applied to the representation of digital bone and chest radiographs. Results: The FIR filtering improved the MTF values by up to almost 1.0 or greater over the frequency range of interest, while it minimally increased the WS values. Combining the inverses of the display MTFs with the response of the human eye led to further refinement of the MTF. Our method was successfully and beneficially applied to the image interpretation of bone radiographs. The resolution enhancement of chest radiographs, which include larger scattered radiation than bone radiographs, was easily perceived by incorporating the response of the human eye. In addition, no artifacts were observed on the processed images. Conclusion: Our proposed method to compensate for the degradation of the resolution properties of LCDs has the potential to improve the observer performance of radiologists when reading digital radiographs. This work was supported in part by grant from EIZO Corporation.« less
Shults, Ruth A; Williams, Allan F
2017-09-01
The Monitoring the Future (MTF) survey provides nationally-representative annual estimates of licensure and driving patterns among U.S. teens. A previous study using MTF data reported substantial declines in the proportion of high school seniors that were licensed to drive and increases in the proportion of nondrivers following the recent U.S. economic recession. To explore whether licensure and driving patterns among U.S. high school seniors have rebounded in the post-recession years, we analyzed MTF licensure and driving data for the decade of 2006-2015. We also examined trends in teen driver involvement in fatal and nonfatal injury crashes for that decade using data from the Fatality Analysis Reporting System and National Automotive Sampling System General Estimates System, respectively. During 2006-2015, the proportion of high school seniors that reported having a driver's license declined by 9 percentage points (11%) from 81% to 72% and the proportion that did not drive during an average week increased by 8 percentage points (44%) from 18% to 26%. The annual proportion of black seniors that did not drive was consistently greater than twice the proportion of nondriving white seniors. Overall during the decade, 17- and 18-year-old drivers experienced large declines in fatal and nonfatal injury crashes, although crashes increased in both 2014 and 2015. The MTF data indicate that licensure and driving patterns among U.S. high school seniors have not rebounded since the economic recession. The recession had marked negative effects on teen employment opportunities, which likely influenced teen driving patterns. Possible explanations for the apparent discrepancies between the MTF data and the 2014 and 2015 increases in crashes are explored. MTF will continue to be an important resource for clarifying teen driving trends in relation to crash trends and informing strategies to improve teen driver safety. Published by Elsevier Ltd.
MO-F-CAMPUS-J-04: One-Year Analysis of Elekta CBCT Image Quality Using NPS and MTF
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakahara, S; Tachibana, M; Watanabe, Y
2015-06-15
Purpose: To compare quantitative image quality (IQ) evaluation methods using Noise Power Spectrum (NPS) and Modulation Transfer Function (MTF) with standard IQ analyses for minimizing the observer subjectivity of the standard methods and maximizing the information content. Methods: For our routine IQ tests of Elekta XVI Cone-Beam CT, image noise was quantified by the standard deviation of CT number (CT#) (Sigma) over a small area in an IQ test phantom (CatPhan), and the high spatial resolution (HSR) was evaluated by the number of line-pairs (LP#) visually recognizable on the image. We also measured the image uniformity, the low contrast resolutionmore » ratio, and the distances of two points for geometrical accuracy. For this study, we did additional evaluation of the XVI data for 12 monthly IQ tests by using NPS for noise, MTF for HSR, and the CT#-to-density relationship. NPS was obtained by applying Fourier analysis in a small area on the uniformity test section of CatPhan. The MTF analysis was performed by applying the Droege-Morin (D-M) method to the line pairs on the phantom. The CT#-to-density was obtained for inserts in the low-contrast test section of the phantom. Results: All the quantities showed a noticeable change over the one-year period. Especially the noise level changed significantly after a repair of the imager. NPS was more sensitive to the IQ change than Sigma. MTF could provide more quantitative and objective evaluation of the HSR. The CT# was very different from the expected CT#; but, the CT#-to-density curves were constant within 5% except two months. Conclusion: Since the D-M method is easy to implement, we recommend using MTF instead of the LP# even for routine periodic QA. The month-to-month variation of IQ was not negligible; hence a routine IQ test must be performed, particularly after any modification of hardware including detector calibration.« less
Bergfeld, Wilma; Washenik, Ken; Callender, Valerie; Zhang, Paul; Quiza, Carlos; Doshi, Uday; Blume-Peytavi, Ulrike
2016-07-01
BACKGROUND Female pattern hair loss (FPHL) is a common hair disorder that affects millions of women. A new 5% minoxidil topical foam (MTF) formulation, which does not contain propylene glycol, has been developed.
To compare the efficacy and safety of once-daily 5% MTF with vehicle foam for the treatment of FPHL.
This was a Phase III, randomized, double-blind, vehicle-controlled, parallel-group, international multicenter trial (17 sites) in women aged at least 18 years with FPHL (grade D3 to D6 on the Savin Density Scale), treated once daily with 5% MTF or vehicle foam for 24 weeks. The co-primary efficacy endpoints were the change from baseline at week 24 in target area hair count (TAHC) and subject assessment of scalp coverage. Also evaluated were TAHC at week 12, expert panel review of hair regrowth at week 24, and change from baseline in total unit area density (TUAD, sum of hair diameters/cm2) at weeks 12 and 24.
A total of 404 women were enrolled. At 12 and 24 weeks, 5% MTF treatment resulted in regrowth of 10.9 hairs/cm2 and 9.1 hairs/cm2 more than vehicle foam, respectively (both P<.0001). Improved scalp coverage at week 24 was observed by both subject self-assessment (0.69-point improvement over vehicle foam; P<.0001) and expert panel review (0.36-point improvement over the vehicle foam; P<.0001). TUAD increased by 658 μm/cm2 and 644 μm/cm2 more with 5% MTF than with vehicle foam at weeks 12 and 24, respectively (both P<.0001). MTF was well tolerated. A low incidence of scalp irritation and facial hypertrichosis was observed, with no clinically significant differences between groups.
Five percent MTF once daily for 24 weeks was well tolerated and promoted hair regrowth in women with FPHL, resulting in improved scalp coverage and increased hair density compared with vehicle foam. ClinicalTrials.gov identifier: nCT01226459
J Drugs Dermatol. 2016;15(7):874-881.
Anderson localization of partially incoherent light
DOE Office of Scientific and Technical Information (OSTI.GOV)
Capeta, D.; Radic, J.; Buljan, H.
We study Anderson localization and propagation of partially spatially incoherent wavepackets in linear disordered potentials, motivated by the insight that interference phenomena resulting from multiple scattering are affected by the coherence of the waves. We find that localization is delayed by incoherence: the more incoherent the waves are, the longer they diffusively spread while propagating in the medium. However, if all the eigenmodes of the system are exponentially localized (as in one- and two-dimensional disordered systems), any partially incoherent wavepacket eventually exhibits localization with exponentially decaying tails, after sufficiently long propagation distances. Interestingly, we find that the asymptotic behavior ofmore » the incoherent beam is similar to that of a single instantaneous coherent realization of the beam.« less
NASA Astrophysics Data System (ADS)
Hirigoyen, Flavien; Crocherie, Axel; Vaillant, Jérôme M.; Cazaux, Yvon
2008-02-01
This paper presents a new FDTD-based optical simulation model dedicated to describe the optical performances of CMOS image sensors taking into account diffraction effects. Following market trend and industrialization constraints, CMOS image sensors must be easily embedded into even smaller packages, which are now equipped with auto-focus and short-term coming zoom system. Due to miniaturization, the ray-tracing models used to evaluate pixels optical performances are not accurate anymore to describe the light propagation inside the sensor, because of diffraction effects. Thus we adopt a more fundamental description to take into account these diffraction effects: we chose to use Maxwell-Boltzmann based modeling to compute the propagation of light, and to use a software with an FDTD-based (Finite Difference Time Domain) engine to solve this propagation. We present in this article the complete methodology of this modeling: on one hand incoherent plane waves are propagated to approximate a product-use diffuse-like source, on the other hand we use periodic conditions to limit the size of the simulated model and both memory and computation time. After having presented the correlation of the model with measurements we will illustrate its use in the case of the optimization of a 1.75μm pixel.
ERIC Educational Resources Information Center
Hsiung, Chin-Min; Zheng, Xiang-Xiang
2015-01-01
The Measurements for Team Functioning (MTF) database contains a series of student academic performance measurements obtained at a national university in Taiwan. The measurements are acquired from unit tests and homework tests performed during a core mechanical engineering course, and provide an objective means of assessing the functioning of…
Dynamic MTF, an innovative test bench for detector characterization
NASA Astrophysics Data System (ADS)
Emmanuel, Rossi; Raphaël, Lardière; Delmonte, Stephane
2017-11-01
PLEIADES HR are High Resolution satellites for Earth observation. Placed at 695km they reach a 0.7m spatial resolution. To allow such performances, the detectors are working in a TDI mode (Time and Delay Integration) which consists in a continuous charge transfer from one line to the consecutive one while the image is passing on the detector. The spatial resolution, one of the most important parameter to test, is characterized by the MTF (Modulation Transfer Function). Usually, detectors are tested in a staring mode. For a higher level of performances assessment, a dedicated bench has been set-up, allowing detectors' MTF characterization in the TDI mode. Accuracy and reproducibility are impressive, opening the door to new perspectives in term of HR imaging systems testing.
MTF Analysis of LANDSAT-4 Thematic Mapper
NASA Technical Reports Server (NTRS)
Schowengerdt, R.
1984-01-01
A research program to measure the LANDSAT 4 Thematic Mapper (TM) modulation transfer function (MTF) is described. Measurement of a satellite sensor's MTF requires the use of a calibrated ground target, i.e., the spatial radiance distribution of the target must be known to a resolution at least four to five times greater than that of the system under test. A small reflective mirror or a dark light linear pattern such as line or edge, and relatively high resolution underflight imagery are used to calibrate the target. A technique that utilizes an analytical model for the scene spatial frequency power spectrum will be investigated as an alternative to calibration of the scene. The test sites and analysis techniques are also described.
Zhao, Qi; Liu, Yunchao; Yuan, Xiao; Chitambar, Eric; Ma, Xiongfeng
2018-02-16
Manipulation and quantification of quantum resources are fundamental problems in quantum physics. In the asymptotic limit, coherence distillation and dilution have been proposed by manipulating infinite identical copies of states. In the nonasymptotic setting, finite data-size effects emerge, and the practically relevant problem of coherence manipulation using finite resources has been left open. This Letter establishes the one-shot theory of coherence dilution, which involves converting maximally coherent states into an arbitrary quantum state using maximally incoherent operations, dephasing-covariant incoherent operations, incoherent operations, or strictly incoherent operations. We introduce several coherence monotones with concrete operational interpretations that estimate the one-shot coherence cost-the minimum amount of maximally coherent states needed for faithful coherence dilution. Furthermore, we derive the asymptotic coherence dilution results with maximally incoherent operations, incoherent operations, and strictly incoherent operations as special cases. Our result can be applied in the analyses of quantum information processing tasks that exploit coherence as resources, such as quantum key distribution and random number generation.
NASA Astrophysics Data System (ADS)
Zhao, Qi; Liu, Yunchao; Yuan, Xiao; Chitambar, Eric; Ma, Xiongfeng
2018-02-01
Manipulation and quantification of quantum resources are fundamental problems in quantum physics. In the asymptotic limit, coherence distillation and dilution have been proposed by manipulating infinite identical copies of states. In the nonasymptotic setting, finite data-size effects emerge, and the practically relevant problem of coherence manipulation using finite resources has been left open. This Letter establishes the one-shot theory of coherence dilution, which involves converting maximally coherent states into an arbitrary quantum state using maximally incoherent operations, dephasing-covariant incoherent operations, incoherent operations, or strictly incoherent operations. We introduce several coherence monotones with concrete operational interpretations that estimate the one-shot coherence cost—the minimum amount of maximally coherent states needed for faithful coherence dilution. Furthermore, we derive the asymptotic coherence dilution results with maximally incoherent operations, incoherent operations, and strictly incoherent operations as special cases. Our result can be applied in the analyses of quantum information processing tasks that exploit coherence as resources, such as quantum key distribution and random number generation.
Spectral long-range interaction of temporal incoherent solitons.
Xu, Gang; Garnier, Josselin; Picozzi, Antonio
2014-02-01
We study the interaction of temporal incoherent solitons sustained by a highly noninstantaneous (Raman-like) nonlinear response. The incoherent solitons exhibit a nonmutual interaction, which can be either attractive or repulsive depending on their relative initial distance. The analysis reveals that incoherent solitons exhibit a long-range interaction in frequency space, which is in contrast with the expected spectral short-range interaction described by the usual approach based on the Raman-like spectral gain curve. Both phenomena of anomalous interaction and spectral long-range behavior of incoherent solitons are described in detail by a long-range Vlasov equation.
Monaco, Gaspare; Gari, Mariangela; Di Censo, Fabio; Poscia, Andrea; Ruggi, Giada; Scialdone, Antonio
2017-06-01
To compare the visual outcomes and quality of vision of 2 new diffractive multifocal intraocular lenses (IOLs) with those of a monofocal IOL. Fatebenefratelli e Oftalmico Hospital, Milan, Italy. Prospective case series. Patients had bilateral cataract surgery with implantation of a trifocal IOL (Panoptix), an extended-range-of-vision IOL (Symfony), or a monofocal IOL (SN60WF). Postoperative examinations included assessing distance, intermediate, and near visual acuity; binocular defocus; intraocular and total aberrations; point-spread function (PSF); modulation transfer function (MTF); retinal straylight; and quality-of-vision (QoV) and spectacle-dependence questionnaires. Seventy-six patients (152 eyes) were assessed for study eligibility. Twenty patients (40 eyes) in each arm of the study (60 patients, 120 eyes) completed the outcome assessment. At the 4-month follow-up, the trifocal group had significantly better near visual acuity than the extended-range-of-vision group (P = .005). The defocus curve showed the trifocal IOL had better intermediate/near performance than the extended-range-of-vision IOL and both multifocal IOLs performed better than the monofocal IOL. Intragroup comparison of the total higher-order aberrations, PSF, MTF, and retinal straylight were not statistically different. The QoV questionnaire results showed no differences in dysphotopsia between the multifocal IOL groups; however, the results were significantly higher than in the monofocal IOL group. Both multifocal IOLs seemed to be good options for patients with intermediate-vision requirements, whereas the trifocal IOL might be better for patients with near-vision requirements. The significant perception of visual side effects indicates that patients still must be counseled about these effects before a multifocal IOL is implanted. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Blume-Peytavi, Ulrike; Shapiro, Jerry; Messenger, Andrew G; Hordinsky, Maria K; Zhang, Paul; Quiza, Carlos; Doshi, Uday; Olsen, Elise A
2016-07-01
A once-daily minoxidil topical foam (MTF) has been developed to treat female pattern hair loss.
Determine noninferiority of once-daily 5% MTF versus twice-daily 2% minoxidil topical solution (MTS) based on the change from baseline in target area hair count (TAHC) at 24 weeks. In a randomized, phase III trial, women with female pattern hair loss received once-daily 5% MTF (n=161) or twice-daily 2% MTS (n=161) for 52 weeks. Primary endpoint was change from baseline in TAHC at 24 weeks. Secondary endpoint was change from baseline in TAHC at 12 weeks. Exploratory endpoints included change in total unit area density and change in overall scalp coverage.
Once-daily 5% MTF increased TAHC from baseline (adjusted mean ± standard error) by 23.9 ± 2.1 hairs/cm2 at week 24. Twice-daily 2% MTS increased TAHC 24.2 ± 2.1 hairs/cm2 at week 24. The treatment difference was -0.3 hairs/cm2 (95% CI = -6.0, 5.4). Since the lower bound of the 95% CI was less than -5.0, the prespecified noninferiority goal was not met. Both treatments were well tolerated.
Once-daily 5% MTF and twice-daily 2% MTS induced hair regrowth in female pattern hair loss, but prespecified noninferiority criteria were not met.
ClinicalTrials.gov identifier: NCT01145625
J Drugs Dermatol. 2016;15(7):883-889.
Towards the Experimental Assessment of the DQE in SPECT Scanners
NASA Astrophysics Data System (ADS)
Fountos, G. P.; Michail, C. M.
2017-11-01
The purpose of this work was to introduce the Detective Quantum Efficiency (DQE) in single photon emission computed tomography (SPECT) systems using a flood source. A Tc-99m-based flood source (Eγ = 140 keV) consisting of a radiopharmaceutical solution of dithiothreitol (DTT, 10-3 M)/Tc-99m(III)-DMSA, 40 mCi/40 ml bound to the grains of an Agfa MammoRay HDR Medical X-ray film) was prepared in laboratory. The source was placed between two PMMA blocks and images were obtained by using the brain tomographic acquisition protocol (DatScan-brain). The Modulation Transfer Function (MTF) was evaluated using the Iterative 2D algorithm. All imaging experiments were performed in a Siemens e-Cam gamma camera. The Normalized Noise Power spectra (NNPS) were obtained from the sagittal views of the source. The higher MTF values were obtained for the Flash Iterative 2D with 24 iterations and 20 subsets. The noise levels of the SPECT reconstructed images, in terms of the NNPS, were found to increase as the number of iterations increase. The behavior of the DQE was influenced by both MTF and NNPS. As the number of iterations was increased, higher MTF values were obtained, however with a parallel, increase of magnitude in image noise, as depicted from the NNPS results. DQE values, which were influenced by both MTF and NNPS, were found higher when the number of iterations results in resolution saturation. The method presented here is novel and easy to implement, requiring materials commonly found in clinical practice and can be useful in the quality control of SPECT scanners.
Watanabe, Hiroshi; Nomura, Yoshikazu; Kuribayashi, Ami; Kurabayashi, Tohru
2018-02-01
We aimed to employ the Radia diagnostic software with the safety and efficacy of a new emerging dental X-ray modality (SEDENTEXCT) image quality (IQ) phantom in CT, and to evaluate its validity. The SEDENTEXCT IQ phantom and Radia diagnostic software were employed. The phantom was scanned using one medical full-body CT and two dentomaxillofacial cone beam CTs. The obtained images were imported to the Radia software, and the spatial resolution outputs were evaluated. The oversampling method was employed using our original wire phantom as a reference. The resultant modulation transfer function (MTF) curves were compared. The null hypothesis was that MTF curves generated using both methods would be in agreement. One-way analysis of variance tests were applied to the f50 and f10 values from the MTF curves. The f10 values were subjectively confirmed by observing the line pair modules. The Radia software reported the MTF curves on the xy-plane of the CT scans, but could not return f50 and f10 values on the z-axis. The null hypothesis concerning the reported MTF curves on the xy-plane was rejected. There were significant differences between the results of the Radia software and our reference method, except for f10 values in CS9300. These findings were consistent with our line pair observations. We evaluated the validity of the Radia software with the SEDENTEXCT IQ phantom. The data provided were semi-automatic, albeit with problems and statistically different from our reference. We hope the manufacturer will overcome these limitations.
Parham, Sophie C; Kavanagh, David J; Gericke, Christian A; King, Neil; May, Jon; Andrade, Jackie
2017-06-01
There is a need for improved measurement of motivation for diabetes self-care. The Elaborated Intrusion Theory of Desire offers a coherent framework for understanding and identifying the cognitive-affective events that constitute the subjective experience of motivation and may therefore inform the development of such an instrument. Recent research has shown the resultant Motivation Thought Frequency scale (MTF) to have a stable factor structure (Intensity, Incentives Imagery, Self-Efficacy Imagery, Availability) when applied to physical activity, excessive snacking or alcohol use in the general population. The current study aimed to confirm the four-factor structure of the MTF for glucose testing, physical activity and healthy eating in people with type 2 diabetes. Associations with self-reports of concurrent diabetic self-care behaviours were also examined. Confirmatory factor analyses tested the internal structure, and multiple regressions assessed the scale's relationship with concurrent self-care behaviours. The MTF was completed by 340 adults with type 2 diabetes, and 237 from that sample also reported self-care behaviours. Separate MTFs assessed motivation for glucose testing, physical activity and healthy eating. Self-care was assessed using questions from the Summary of Diabetes Self-Care Activities. The MTF for each goal achieved an acceptable fit on all indices after selected errors within factors were allowed to intercorrelate. Intensity and Self-Efficacy Imagery provided the strongest and most consistent correlations with relevant self-care behaviours. Results provide preliminary support for the MTF in a diabetes sample. Testing of its sensitivity to change and its predictive utility over time is needed.
Performance characteristics of a Kodak computed radiography system.
Bradford, C D; Peppler, W W; Dobbins, J T
1999-01-01
The performance characteristics of a photostimulable phosphor based computed radiographic (CR) system were studied. The modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE) of the Kodak Digital Science computed radiography (CR) system (Eastman Kodak Co.-model 400) were measured and compared to previously published results of a Fuji based CR system (Philips Medical Systems-PCR model 7000). To maximize comparability, the same measurement techniques and analysis methods were used. The DQE at four exposure levels (30, 3, 0.3, 0.03 mR) and two plate types (standard and high resolution) were calculated from the NPS and MTF measurements. The NPS was determined from two-dimensional Fourier analysis of uniformly exposed plates. The presampling MTF was determined from the Fourier transform (FT) of the system's finely sampled line spread function (LSF) as produced by a narrow slit. A comparison of the slit type ("beveled edge" versus "straight edge") and its effect on the resulting MTF measurements was also performed. The results show that both systems are comparable in resolution performance. The noise power studies indicated a higher level of noise for the Kodak images (approximately 20% at the low exposure levels and 40%-70% at higher exposure levels). Within the clinically relevant exposure range (0.3-3 mR), the resulting DQE for the Kodak plates ranged between 20%-50% lower than for the corresponding Fuji plates. Measurements of the presampling MTF with the two slit types have shown that a correction factor can be applied to compensate for transmission through the relief edges.
Image quality of the cat eye measured during retinal ganglion cell experiments
Bonds, A. B.; Enroth-Cugell, Christina; Pinto, L. H.
1972-01-01
1. The modulation transfer function (MTF) of the dioptrics of fifteen cat eyes was determined. The aerial image, formed by the eye of a standard object (a 0·5-1·0° annulus), was photographed. The transmission of the film negative was measured with a scanning microdensitometer to yield the light distribution within the aerial image. Correcting for the double passage, this experimentally determined light distribution and the known object light distribution were used to obtain the MTF, applying Fourier methods. Each MTF was used to calculate the light distribution within the retinal image of stimuli of various geometry used in experiments on retinal ganglion cells in the same eye. 2. When the eye was equipped with an artificial pupil of the same size as that used in the neurophysiological experiments (4·0-4·8 mm diam.) the MTF had fallen to 0·5 at 2·43 c/deg. When the pupil was removed the MTF had fallen to 0·5 at a much lower spatial frequency (1·0 c/deg). This shows that even when one uses an artificial pupil too large to provide optimal image quality there is a vast improvement over using no pupil. 3. These image quality measurements were prompted by the need to know the actual stimulus image in experiments on the functional organization of the receptive field, a need exemplified in this paper by a few specific physiological results. The full neurophysiological results appear in the next two papers. ImagesFig. 3Fig. 4 PMID:5014105
Brüllmann, D D; d'Hoedt, B
2011-05-01
The aim of this study was to illustrate the influence of digital filters on the signal-to-noise ratio (SNR) and modulation transfer function (MTF) of digital images. The article will address image pre-processing that may be beneficial for the production of clinically useful digital radiographs with lower radiation dose. Three filters, an arithmetic mean filter, a median filter and a Gaussian filter (standard deviation (SD) = 0.4), with kernel sizes of 3 × 3 pixels and 5 × 5 pixels were tested. Synthetic images with exactly increasing amounts of Gaussian noise were created to gather linear regression of SNR before and after application of digital filters. Artificial stripe patterns with defined amounts of line pairs per millimetre were used to calculate MTF before and after the application of the digital filters. The Gaussian filter with a 5 × 5 kernel size caused the highest noise suppression (SNR increased from 2.22, measured in the synthetic image, to 11.31 in the filtered image). The smallest noise reduction was found with the 3 × 3 median filter. The application of the median filters resulted in no changes in MTF at the different resolutions but did result in the deletion of smaller structures. The 5 × 5 Gaussian filter and the 5 × 5 arithmetic mean filter showed the strongest changes of MTF. The application of digital filters can improve the SNR of a digital sensor; however, MTF can be adversely affected. As such, imaging systems should not be judged solely on their quoted spatial resolutions because pre-processing may influence image quality.
ERIC Educational Resources Information Center
Miech, Richard A.; Johnston, Lloyd D.; O'Malley, Patrick M.; Bachman, Jerald G.; Schulenberg, John E.; Patrick, Megan E.
2017-01-01
Monitoring the Future (MTF) is designed to give sustained attention to substance use among the nation's youth and adults. It is an investigator-initiated study that originated with and is conducted by a team of research professors at the University of Michigan's Institute for Social Research. Since its onset in 1975, MTF has been continuously…
ERIC Educational Resources Information Center
Miech, Richard A.; Johnston, Lloyd D.; O'Malley, Patrick M.; Bachman, Jerald G.; Schulenberg, John E.
2016-01-01
Monitoring the Future (MTF) is designed to give sustained attention to substance use among the nation's youth and adults. It is an investigator-initiated study that originated with and is conducted by a team of research professors at the University of Michigan's Institute for Social Research. Since its onset in 1975, MTF has been continuously…
Examining the Spatial Frequency Components of a Digital Dental Detector
NASA Astrophysics Data System (ADS)
Anastasiou, A.; Michail, C.; Koukou, V.; Martini, N.; Bakas, A.; Papastamati, F.; Maragkaki, P.; Lavdas, L.; Fountos, G.; Valais, I.; Kalyvas, N.
2017-11-01
Digital X-ray detectors are widely used in dental radiography. The scope of this work is the examination of the spatial frequency component of a dedicated dental CMOS detector. A commercially available SCHICK CDR CMOS detector was irradiated at a Del Medical Eureka X-ray system at 60kVp and 70kVp. The irradiation setup included images of an edge, for Modulation Transfer Function (MTF) calculation. The air-KERMA was measured with an RTI PIRANHA X-ray multimeter. The images were evaluated in ‘for presentation’ format with the use of ImageJ software. The linear range of the detector was found in the range 13μGy-183μGy at 60 kVp and 18μGy-180μGy at 70 kVp. By inspecting the MTF curves it was found that MTF(6lp/mm)60kVp=0.29 and MTF(6lp/mm)70kVp=0.25. The inspection of the Normalized Noise Power Spetrum (NNPS) showed similar low noise components. Our results indicate that this detector presents comparable performance at both kVp, although its X-ray response (pixel value vs air KERMA) was not equal to previously published results, for the same detector type.
Parsanezhad, M E; Alborzi, S; Zarei, A; Dehbashi, S; Omrani, G
2001-10-01
To evaluate the clinical features, endocrine and metabolic profiles in clomiphene (CC) responders and non-responders with polycystic ovarian disease (PCOD), and to examine the effects of metformin (MTF) on the above parameters of CC resistance. A prospective clinical trial was undertaken at the infertility division of a university teaching hospital. Forty-one CC responders were selected and their hormonal and clinical features were determined. Forty-one CC-resistant PCOD women were also selected and clinical features; metabolic and hormonal profiles before and after treatment with MTF 1500 mg/day for 6-8 weeks were evaluated. Women who failed to conceive were treated by CC while continuing to take MTF. CC responders had higher insulin levels while non-responders were hyperinsulinemic. Menstrual irregularities improved in 30%. Mean+/-S.D. area under curve of insulin decreased from 297.58+/-191.33 to 206+/-0.1 mIU/ml per min (P=0.005). Only 39.39% ovulated and 24.24% conceived. PCOD is associated with insulin resistance (IR) particularly in CC-resistant women. Insulin resistance and androgen levels are significantly higher in obese patients. MTF therapy improved hyperandrogenemia, IR, and pregnancy rate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Melnyk, Roman; DiBianca, Frank A.
The detector presampling modulation transfer function (MTF) of a 576-channel variable resolution x-ray (VRX) computed tomography (CT) scanner was evaluated in this study. The scanner employs a VRX detector, which provides increased spatial resolution by matching the scanner's field of view (FOV) to the size of an object being imaged. Because spatial resolution is the parameter the scanner promises to improve, the evaluation of this resolution is important. The scanner's pre-reconstruction spatial resolution, represented by the detector presampling MTF, was evaluated using both modeling (Monte Carlo simulation) and measurement (the moving slit method). The theoretical results show the increase inmore » the cutoff frequency of the detector presampling MTF from 1.39 to 43.38 cycles/mm as the FOV of the VRX CT scanner decreases from 32 to 1 cm. The experimental results are in reasonable agreement with the theoretical data. Some discrepancies between the measured and the modeled detector presampling MTFs can be explained by the limitations of the model. At small FOVs (1-8 cm), the MTF measurements were limited by the size of the focal spot. The obtained results are important for further development of the VRX CT scanner.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yashchuk, V. V.; Fischer, P. J.; Chan, E. R.
We present a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) one-dimensional sequences and two-dimensional arrays as an effective method for spectral characterization in the spatial frequency domain of a broad variety of metrology instrumentation, including interferometric microscopes, scatterometers, phase shifting Fizeau interferometers, scanning and transmission electron microscopes, and at this time, x-ray microscopes. The inherent power spectral density of BPR gratings and arrays, which has a deterministic white-noise-like character, allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field of view of an instrument. We demonstrate themore » MTF calibration and resolution characterization over the full field of a transmission soft x-ray microscope using a BPR multilayer (ML) test sample with 2.8 nm fundamental layer thickness. We show that beyond providing a direct measurement of the microscope's MTF, tests with the BPRML sample can be used to fine tune the instrument's focal distance. Finally, our results confirm the universality of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yashchuk, V. V., E-mail: VVYashchuk@lbl.gov; Chan, E. R.; Lacey, I.
We present a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) one-dimensional sequences and two-dimensional arrays as an effective method for spectral characterization in the spatial frequency domain of a broad variety of metrology instrumentation, including interferometric microscopes, scatterometers, phase shifting Fizeau interferometers, scanning and transmission electron microscopes, and at this time, x-ray microscopes. The inherent power spectral density of BPR gratings and arrays, which has a deterministic white-noise-like character, allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field of view of an instrument. We demonstrate themore » MTF calibration and resolution characterization over the full field of a transmission soft x-ray microscope using a BPR multilayer (ML) test sample with 2.8 nm fundamental layer thickness. We show that beyond providing a direct measurement of the microscope’s MTF, tests with the BPRML sample can be used to fine tune the instrument’s focal distance. Our results confirm the universality of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.« less
Chiu, Sheng-Yi; Kao, Chien-Ya; Huang, Tzu-Ting; Lin, Chia-Jung; Ong, Seow-Chin; Chen, Chun-Da; Chang, Jo-Shu; Lin, Chih-Sheng
2011-10-01
The growth and on-site bioremediation potential of an isolated thermal- and CO₂-tolerant mutant strain, Chlorella sp. MTF-7, were investigated. The Chlorella sp. MTF-7 cultures were directly aerated with the flue gas generated from coke oven of a steel plant. The biomass concentration, growth rate and lipid content of Chlorella sp. MTF-7 cultured in an outdoor 50-L photobioreactor for 6 days was 2.87 g L⁻¹ (with an initial culture biomass concentration of 0.75 g L⁻¹), 0.52 g L⁻¹ d⁻¹ and 25.2%, respectively. By the operation with intermittent flue gas aeration in a double-set photobioreactor system, average efficiency of CO₂ removal from the flue gas could reach to 60%, and NO and SO₂ removal efficiency was maintained at approximately 70% and 50%, respectively. Our results demonstrate that flue gas from coke oven could be directly introduced into Chlorella sp. MTF-7 cultures to potentially produce algal biomass and efficiently capture CO₂, NO and SO₂ from flue gas. Copyright © 2011 Elsevier Ltd. All rights reserved.
Influence of Iterative Reconstruction Algorithms on PET Image Resolution
NASA Astrophysics Data System (ADS)
Karpetas, G. E.; Michail, C. M.; Fountos, G. P.; Valais, I. G.; Nikolopoulos, D.; Kandarakis, I. S.; Panayiotakis, G. S.
2015-09-01
The aim of the present study was to assess image quality of PET scanners through a thin layer chromatography (TLC) plane source. The source was simulated using a previously validated Monte Carlo model. The model was developed by using the GATE MC package and reconstructed images obtained with the STIR software for tomographic image reconstruction. The simulated PET scanner was the GE DiscoveryST. A plane source consisted of a TLC plate, was simulated by a layer of silica gel on aluminum (Al) foil substrates, immersed in 18F-FDG bath solution (1MBq). Image quality was assessed in terms of the modulation transfer function (MTF). MTF curves were estimated from transverse reconstructed images of the plane source. Images were reconstructed by the maximum likelihood estimation (MLE)-OSMAPOSL, the ordered subsets separable paraboloidal surrogate (OSSPS), the median root prior (MRP) and OSMAPOSL with quadratic prior, algorithms. OSMAPOSL reconstruction was assessed by using fixed subsets and various iterations, as well as by using various beta (hyper) parameter values. MTF values were found to increase with increasing iterations. MTF also improves by using lower beta values. The simulated PET evaluation method, based on the TLC plane source, can be useful in the resolution assessment of PET scanners.
Regional gray matter variation in male-to-female transsexualism
Luders, Eileen; Sánchez, Francisco J.; Gaser, Christian; Toga, Arthur W.; Narr, Katherine L.; Hamilton, Liberty S.; Vilain, Eric
2009-01-01
Gender identity—one's sense of being a man or a woman—is a fundamental perception experienced by all individuals that extends beyond biological sex. Yet, what contributes to our sense of gender remains uncertain. Since individuals who identify as transsexual report strong feelings of being the opposite sex and a belief that their sexual characteristics do not reflect their true gender, they constitute an invaluable model to understand the biological underpinnings of gender identity. We analyzed MRI data of 24 male-to-female (MTF) transsexuals not yet treated with cross-sex hormones in order to determine whether gray matter volumes in MTF transsexuals more closely resemble people who share their biological sex (30 control men), or people who share their gender identity (30 control women). Results revealed that regional gray matter variation in MTF transsexuals is more similar to the pattern found in men than in women. However, MTF transsexuals show a significantly larger volume of regional gray matter in the right putamen compared to men. These findings provide new evidence that transsexualism is associated with distinct cerebral pattern, which supports the assumption that brain anatomy plays a role in gender identity. PMID:19341803
Regional gray matter variation in male-to-female transsexualism.
Luders, Eileen; Sánchez, Francisco J; Gaser, Christian; Toga, Arthur W; Narr, Katherine L; Hamilton, Liberty S; Vilain, Eric
2009-07-15
Gender identity-one's sense of being a man or a woman-is a fundamental perception experienced by all individuals that extends beyond biological sex. Yet, what contributes to our sense of gender remains uncertain. Since individuals who identify as transsexual report strong feelings of being the opposite sex and a belief that their sexual characteristics do not reflect their true gender, they constitute an invaluable model to understand the biological underpinnings of gender identity. We analyzed MRI data of 24 male-to-female (MTF) transsexuals not yet treated with cross-sex hormones in order to determine whether gray matter volumes in MTF transsexuals more closely resemble people who share their biological sex (30 control men), or people who share their gender identity (30 control women). Results revealed that regional gray matter variation in MTF transsexuals is more similar to the pattern found in men than in women. However, MTF transsexuals show a significantly larger volume of regional gray matter in the right putamen compared to men. These findings provide new evidence that transsexualism is associated with distinct cerebral pattern, which supports the assumption that brain anatomy plays a role in gender identity.
Oh, Seok-Kyun; Kim, Gwang-Won; Yang, Jong-Chul; Kim, Seok-Kwun; Kang, Heoung-Keun
2012-01-01
Objective This study used functional magnetic resonance imaging (fMRI) to contrast the differential brain activation patterns in response to visual stimulation with both male and female erotic nude pictures in male-to-female (MTF) transsexuals who underwent a sex reassignment surgery. Materials and Methods A total of nine healthy MTF transsexuals after a sex reassignment surgery underwent fMRI on a 3.0 Tesla MR Scanner. The brain activation patterns were induced by visual stimulation with both male and female erotic nude pictures. Results The sex hormone levels of the postoperative MTF transsexuals were in the normal range of healthy heterosexual females. The brain areas, which were activated by viewing male nude pictures when compared with viewing female nude pictures, included predominantly the cerebellum, hippocampus, putamen, anterior cingulate gyrus, head of caudate nucleus, amygdala, midbrain, thalamus, insula, and body of caudate nucleus. On the other hand, brain activation induced by viewing female nude pictures was predominantly observed in the hypothalamus and the septal area. Conclusion Our findings suggest that distinct brain activation patterns associated with visual sexual arousal in postoperative MTF transsexuals reflect their sexual orientation to males. PMID:22563262
NASA Astrophysics Data System (ADS)
Yoon, Chun Hong; Yurkov, Mikhail V.; Schneidmiller, Evgeny A.; Samoylova, Liubov; Buzmakov, Alexey; Jurek, Zoltan; Ziaja, Beata; Santra, Robin; Loh, N. Duane; Tschentscher, Thomas; Mancuso, Adrian P.
2016-04-01
The advent of newer, brighter, and more coherent X-ray sources, such as X-ray Free-Electron Lasers (XFELs), represents a tremendous growth in the potential to apply coherent X-rays to determine the structure of materials from the micron-scale down to the Angstrom-scale. There is a significant need for a multi-physics simulation framework to perform source-to-detector simulations for a single particle imaging experiment, including (i) the multidimensional simulation of the X-ray source; (ii) simulation of the wave-optics propagation of the coherent XFEL beams; (iii) atomistic modelling of photon-material interactions; (iv) simulation of the time-dependent diffraction process, including incoherent scattering; (v) assembling noisy and incomplete diffraction intensities into a three-dimensional data set using the Expansion-Maximisation-Compression (EMC) algorithm and (vi) phase retrieval to obtain structural information. We demonstrate the framework by simulating a single-particle experiment for a nitrogenase iron protein using parameters of the SPB/SFX instrument of the European XFEL. This exercise demonstrably yields interpretable consequences for structure determination that are crucial yet currently unavailable for experiment design.
The structure of liquid water by polarized neutron diffraction and reverse Monte Carlo modelling.
Temleitner, László; Pusztai, László; Schweika, Werner
2007-08-22
The coherent static structure factor of water has been investigated by polarized neutron diffraction. Polarization analysis allows us to separate the huge incoherent scattering background from hydrogen and to obtain high quality data of the coherent scattering from four different mixtures of liquid H(2)O and D(2)O. The information obtained by the variation of the scattering contrast confines the configurational space of water and is used by the reverse Monte Carlo technique to model the total structure factors. Structural characteristics have been calculated directly from the resulting sets of particle coordinates. Consistency with existing partial pair correlation functions, derived without the application of polarized neutrons, was checked by incorporating them into our reverse Monte Carlo calculations. We also performed Monte Carlo simulations of a hard sphere system, which provides an accurate estimate of the information content of the measured data. It is shown that the present combination of polarized neutron scattering and reverse Monte Carlo structural modelling is a promising approach towards a detailed understanding of the microscopic structure of water.
Information recovery in propagation-based imaging with decoherence effects
NASA Astrophysics Data System (ADS)
Froese, Heinrich; Lötgering, Lars; Wilhein, Thomas
2017-05-01
During the past decades the optical imaging community witnessed a rapid emergence of novel imaging modalities such as coherent diffraction imaging (CDI), propagation-based imaging and ptychography. These methods have been demonstrated to recover complex-valued scalar wave fields from redundant data without the need for refractive or diffractive optical elements. This renders these techniques suitable for imaging experiments with EUV and x-ray radiation, where the use of lenses is complicated by fabrication, photon efficiency and cost. However, decoherence effects can have detrimental effects on the reconstruction quality of the numerical algorithms involved. Here we demonstrate propagation-based optical phase retrieval from multiple near-field intensities with decoherence effects such as partially coherent illumination, detector point spread, binning and position uncertainties of the detector. Methods for overcoming these systematic experimental errors - based on the decomposition of the data into mutually incoherent modes - are proposed and numerically tested. We believe that the results presented here open up novel algorithmic methods to accelerate detector readout rates and enable subpixel resolution in propagation-based phase retrieval. Further the techniques are straightforward to be extended to methods such as CDI, ptychography and holography.
1999-09-01
PERFORMANCE COMPARISON BETWEEN STEREAUSIS AND INCOHERENT WIDEBAND MUSIC FOR LOCALIZATION OF GROUND VEHICLES September 1999 Tien Pham U.S. Army...present experimental results comparing the incoherent wideband MUSIC (IWM) algorithm developed by the Army Research Laboratory (ARL)1, 2 and the...Type N/A Dates Covered (from... to) ("DD MON YYYY") Title and Subtitle Performance Comparison Between Stereausis and Incoherent Wideband Music for
Model MTF for the mosaic window
NASA Astrophysics Data System (ADS)
Xing, Zhenchong; Hong, Yongfeng; Zhang, Bao
2017-10-01
An electro-optical targeting system mounted either within an airframe or housed in separate pods requires a window to form an environmental barrier to the outside world. In current practice, such windows usually use a mosaic or segmented window. When scanning the target, internally gimbaled systems sweep over the window, which can affect the modulation transfer function (MTF) due to wave-front division and optical path differences arising from the thickness/wedge differences between panes. In this paper, a mathematical model of the MTF of the mosaic window is presented that allows an analysis of influencing factors; we show how the model may be integrated into ZEMAX® software for optical design. The model can be used to guide both the design and the tolerance analysis of optical systems that employ a mosaic window.
NASA Astrophysics Data System (ADS)
Yang, Xusan; Tang, Yuanhe; Liu, Kai; Liu, Hanchen; Gao, Haiyang; Li, Qing; Zhang, Ruixia; Ye, Na; Liang, Yuan; Zhao, Gaoxiang
2008-12-01
Based on the electro-optical properties of liquid crystal, we have designed a novel partial gating detector. Liquid crystal can be taken to change its own transmission according to the light intensity outside. Every single pixel of the image is real-time modulated by liquid crystal, thus the strong light is weakened and low light goes through the detector normally .The purpose of partial-gating strong light (>105lx) can be achieved by this detector. The modulation transfer function (MTF) equations of the main optical sub-systems are calculated in this paper, they are liquid crystal panels, linear fiber panel and CCD array detector. According to the relevant size, the MTF value of this system is fitted out. The result is MTF= 0.518 at Nyquist frequency.
NASA Technical Reports Server (NTRS)
Helder, Dennis; Choi, Taeyoung; Rangaswamy, Manjunath
2005-01-01
The spatial characteristics of an imaging system cannot be expressed by a single number or simple statement. However, the Modulation Transfer Function (MTF) is one approach to measure the spatial quality of an imaging system. Basically, MTF is the normalized spatial frequency response of an imaging system. The frequency response of the system can be evaluated by applying an impulse input. The resulting impulse response is termed the Point Spread function (PSF). This function is a measure of the amount of blurring present in the imaging system and is itself a useful measure of spatial quality. An underlying assumption is that the imaging system is linear and shift-independent. The Fourier transform of the PSF is called the Optical Transfer Function (OTF) and the normalized magnitude of the OTF is the MTF. In addition to using an impulse input, a knife-edge in technique has also been used in this project. The sharp edge exercises an imaging system at all spatial frequencies. The profile of an edge response from an imaging system is called an Edge Spread Function (ESF). Differentiation of the ESF results in a one-dimensional version of the Point Spread Function (PSF). Finally, MTF can be calculated through use of Fourier transform of the PSF as stated previously. Every image includes noise in some degree which makes MTF of PSF estimation more difficult. To avoid the noise effects, many MTF estimation approaches use smooth numerical models. Historically, Gaussian models and Fermi functions were applied to reduce the random noise in the output profiles. The pulse-input method was used to measure the MTF of the Landsat Thematic Mapper (TM) using 8th order even functions over the San Mateo Bridge in San Francisco, California. Because the bridge width was smaller than the 30-meter ground sample distance (GSD) of the TM, the Nyquist frequency was located before the first zero-crossing point of the sinc function from the Fourier transformation of the bridge pulse. To avoid the zero-crossing points in the frequency domain from a pulse, the pulse width should be less than the width of two pixels (or 2 GSD's), but the short extent of the pulse results in a poor signal-to-noise ratio. Similarly, for a high-resolution satellite imaging system such as Quickbird, the input pulse width was critical because of the zero crossing points and noise present in the background area. It is important, therefore, that the width of the input pulse be appropriately sized. Finally, the MTF was calculated by taking ratio between Fourier transform of output and Fourier transform of input. Regardless of whether the edge, pulse and impulse target method is used, the orientation of the targets is critical in order to obtain uniformly spaced sub-pixel data points. When the orientation is incorrect, sample data points tend to be located in clusters that result in poor reconstruction of the edge or pulse profiles. Thus, a compromise orientation must be selected so that all spectral bands can be accommodated. This report continues by outlining the objectives in Section 2, procedures followed in Section 3, descriptions of the field campaigns in Section 4, results in Section 5, and a brief summary in Section 6.
Intercomparison of methods for image quality characterization. I. Modulation transfer function
DOE Office of Scientific and Technical Information (OSTI.GOV)
Samei, Ehsan; Ranger, Nicole T.; Dobbins, James T. III
The modulation transfer function (MTF) and the noise power spectrum (NPS) are widely recognized as the most relevant metrics of resolution and noise performance in radiographic imaging. These quantities have commonly been measured using various techniques, the specifics of which can have a bearing on the accuracy of the results. As a part of a study aimed at comparing the relative performance of different techniques, in this paper we report on a comparison of two established MTF measurement techniques: one using a slit test device [Dobbins et al., Med. Phys. 22, 1581-1593 (1995)] and another using a translucent edge testmore » device [Samei et al., Med. Phys. 25, 102-113 (1998)], with one another and with a third technique using an opaque edge test device recommended by a new international standard (IEC 62220-1, 2003). The study further aimed to substantiate the influence of various acquisition and processing parameters on the estimated MTF. The slit test device was made of 2 mm thick Pb slabs with a 12.5 {mu}m opening. The translucent edge test device was made of a laminated and polished Pt{sub 0.9}Ir{sub 0.1} alloy foil of 0.1 mm thickness. The opaque edge test device was made of a 2 mm thick W slab. All test devices were imaged on a representative indirect flat-panel digital radiographic system using three published beam qualities: 70 kV with 0.5 mm Cu filtration, 70 kV with 19 mm Al filtration, and 74 kV with 21 mm Al filtration (IEC-RQA5). The latter technique was also evaluated in conjunction with two external beam-limiting apertures (per IEC 62220-1), and with the tube collimator limiting the beam to the same area achieved with the apertures. The presampled MTFs were deduced from the acquired images by Fourier analysis techniques, and the results analyzed for relative values and the influence of impacting parameters. The findings indicated that the measurement technique has a notable impact on the resulting MTF estimate, with estimates from the overall IEC method 4.0%{+-}0.2% lower than that of Dobbins et al. and 0.7%{+-}0.4% higher than that of Samei et al. averaged over the zero to cutoff frequency range. Over the same frequency range, keeping beam quality and limitation constant, the average MTF estimate obtained with the edge techniques differed by up to 5.2%{+-}0.2% from that of the slit, with the opaque edge providing lower MTF estimates at lower frequencies than those obtained with the translucent edge or slit. The beam quality impacted the average estimated MTF by as much as 3.7%{+-}0.9% while the use of beam limiting devices alone increased the average estimated MTF by as much as 7.0%{+-}0.9%. While the slit method is inherently very sensitive to misalignment, both edge techniques were found to tolerate misalignments by as much as 6 cm. The results suggest the use of the opaque edge test device and the tube internal collimator for beam limitation in order to achieve an MTF result most reflective of the overall performance of the imaging system and least susceptible to misalignment and scattered radiation. Careful attention to influencing factors is warranted to achieve accurate results.« less
Intercomparison of methods for image quality characterization. I. Modulation transfer function.
Samei, Ehsan; Ranger, Nicole T; Dobbins, James T; Chen, Ying
2006-05-01
The modulation transfer function (MTF) and the noise power spectrum (NPS) are widely recognized as the most relevant metrics of resolution and noise performance in radiographic imaging. These quantities have commonly been measured using various techniques, the specifics of which can have a bearing on the accuracy of the results. As a part of a study aimed at comparing the relative performance of different techniques, in this paper we report on a comparison of two established MTF measurement techniques: one using a slit test device [Dobbins et al., Med. Phys. 22, 1581-1593 (1995)] and another using a translucent edge test device [Samei et al., Med. Phys. 25, 102-113 (1998)], with one another and with a third technique using an opaque edge test device recommended by a new international standard (IEC 62220-1, 2003). The study further aimed to substantiate the influence of various acquisition and processing parameters on the estimated MTF. The slit test device was made of 2 mm thick Pb slabs with a 12.5 microm opening. The translucent edge test device was made of a laminated and polished Pt(0.9)Ir(0.1). alloy foil of 0.1 mm thickness. The opaque edge test device was made of a 2 mm thick W slab. All test devices were imaged on a representative indirect flat-panel digital radiographic system using three published beam qualities: 70 kV with 0.5 mm Cu filtration, 70 kV with 19 mm Al filtration, and 74 kV with 21 mm Al filtration (IEC-RQA5). The latter technique was also evaluated in conjunction with two external beam-limiting apertures (per IEC 62220-1), and with the tube collimator limiting the beam to the same area achieved with the apertures. The presampled MTFs were deduced from the acquired images by Fourier analysis techniques, and the results analyzed for relative values and the influence of impacting parameters. The findings indicated that the measurement technique has a notable impact on the resulting MTF estimate, with estimates from the overall IEC method 4.0% +/- 0.2% lower than that of Dobbins et al. and 0.7% +/- 0.4% higher than that of Samei et al. averaged over the zero to cutoff frequency range. Over the same frequency range, keeping beam quality and limitation constant, the average MTF estimate obtained with the edge techniques differed by up to 5.2% +/- 0.2% from that of the slit, with the opaque edge providing lower MTF estimates at lower frequencies than those obtained with the translucent edge or slit. The beam quality impacted the average estimated MTF by as much as 3.7% +/- 0.9% while the use of beam limiting devices alone increased the average estimated MTF by as much as 7.0% +/- 0.9%. While the slit method is inherently very sensitive to misalignment, both edge techniques were found to tolerate misalignments by as much as 6 cm. The results suggest the use of the opaque edge test device and the tube internal collimator for beam limitation in order to achieve an MTF result most reflective of the overall performance of the imaging system and least susceptible to misalignment and scattered radiation. Careful attention to influencing factors is warranted to achieve accurate results.
Evidence for the onset of color transparency in ρ0 electroproduction off nuclei
NASA Astrophysics Data System (ADS)
CLAS Collaboration; El Fassi, L.; Zana, L.; Hafidi, K.; Holtrop, M.; Mustapha, B.; Brooks, W. K.; Hakobyan, H.; Zheng, X.; Adhikari, K. P.; Adikaram, D.; Aghasyan, M.; Amaryan, M. J.; Anghinolfi, M.; Arrington, J.; Avakian, H.; Baghdasaryan, H.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Biselli, A. S.; Bookwalter, C.; Branford, D.; Briscoe, W. J.; Bültmann, S.; Burkert, V. D.; Carman, D. S.; Celentano, A.; Chandavar, S.; Cole, P. L.; Contalbrigo, M.; Crede, V.; D'Angelo, A.; Daniel, A.; Dashyan, N.; De Vita, R.; De Sanctis, E.; Deur, A.; Dey, B.; Dickson, R.; Djalali, C.; Dodge, G. E.; Doughty, D.; Dupre, R.; Egiyan, H.; El Alaoui, A.; Elouadrhiri, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Gabrielyan, M. Y.; Garçon, M.; Gevorgyan, N.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guidal, M.; Guo, L.; Hanretty, C.; Heddle, D.; Hicks, K.; Holt, R. J.; Hyde, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jawalkar, S. S.; Keller, D.; Khandaker, M.; Khetarpal, P.; Kim, A.; Kim, W.; Klein, A.; Klein, F. J.; Kubarovsky, V.; Kuhn, S. E.; Kuleshov, S. V.; Kuznetsov, V.; Laget, J. M.; Lu, H. Y.; MacGregor, I. J. D.; Mao, Y.; Markov, N.; Mayer, M.; McAndrew, J.; McKinnon, B.; Meyer, C. A.; Mineeva, T.; Mirazita, M.; Mokeev, V.; Moreno, B.; Moutarde, H.; Munevar, E.; Nadel-Turonski, P.; Ni, A.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Pappalardo, L. L.; Paremuzyan, R.; Park, K.; Park, S.; Pasyuk, E.; Anefalos Pereira, S.; Phelps, E.; Pozdniakov, S.; Price, J. W.; Procureur, S.; Protopopescu, D.; Raue, B. A.; Reimer, P. E.; Ricco, G.; Rimal, D.; Ripani, M.; Ritchie, B. G.; Rosner, G.; Rossi, P.; Sabatié, F.; Saini, M. S.; Salgado, C.; Schott, D.; Schumacher, R. A.; Seraydaryan, H.; Sharabian, Y. G.; Smith, E. S.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Stepanyan, S. S.; Stepanyan, S.; Stoler, P.; Strauch, S.; Taiuti, M.; Tang, W.; Taylor, C. E.; Tedeschi, D. J.; Tkachenko, S.; Ungaro, M.; Vernarsky, B.; Vineyard, M. F.; Voskanyan, H.; Voutier, E.; Watts, D.; Weinstein, L. B.; Weygand, D. P.; Wood, M. H.; Zachariou, N.; Zhao, B.; Zhao, Z. W.
2012-06-01
We have measured the nuclear transparency of the incoherent diffractive A(e,e‧ρ0) process in 12C and 56Fe targets relative to 2H using a 5 GeV electron beam. The nuclear transparency, the ratio of the produced ρ0's on a nucleus relative to deuterium, which is sensitive to ρA interaction, was studied as function of the coherence length (lc), a lifetime of the hadronic fluctuation of the virtual photon, and the four-momentum transfer squared (Q2). While the transparency for both 12C and 56Fe showed no lc dependence, a significant Q2 dependence was measured, which is consistent with calculations that included the color transparency effects.
NASA Astrophysics Data System (ADS)
Wang, Xiang; Zhou, Chen
2018-05-01
Incoherent scatter radar (ISR) is the most powerful ground-based measurement facility to study the ionosphere. The plasma lines are not routinely detected by the incoherent scatter radar due to the low intensity, which falls below the measured spectral noise level of the incoherent scatter radar. The plasma lines are occasionally enhanced by suprathermal electrons through the Landau damping process and detectable to the incoherent scatter radar. In this study, by using the European Incoherent Scatter Association (EISCAT) UHF incoherent scatter radar, the experiment observation presents that the enhanced plasma lines were observed. These plasma lines were considered as manifest of the suprathermal electrons generated by the high-frequency heating wave during the ionospheric modification. The electron density profile is also obtained from the enhanced plasma lines. This study can be a promising technique for obtaining the accurate electron density during ionospheric modification experiment.
Phase and group delay of S-band megawatt Cassegrain diplexer and S-band megawatt transmit filter
NASA Technical Reports Server (NTRS)
Lay, R.
1977-01-01
The phase characteristics and group delay of the S-band Megawatt Cassegrain Diplexer (MCD) and S-band Megawatt Transmit Filter (MTF) are reported. These phase measurements on the MCD and MTF were done in response to the need to obtain the total DSS hardware ground delay required for very long baseline interferometry and ranging radio metric measurements.
PRIMUS/NAVCARE Cost-Effectiveness Analysis
1991-04-08
ICD-9-CM diagnosis codes that occurred most frequently in the medical record sample - 328.9 ( otitis media , unspecified) and 465.9 (upper...when attention is focused upon a single diagnosis, the MTF CECs are no longer consistently above the PRIMUS CECs. For otitis media , the MTF CECs are...CHAMPUS-EQUIVALENT COSTS FOR SELECTED DIAGNOSES 328.9 OTITIS MEDIA , UNSPECIFIED Sample Size Mean 95% Confidence Interval Upper Limit Lower
Qi, Meirigeng; Valiente, Luis; McFadden, Brian; Omori, Keiko; Bilbao, Shiela; Juan, Jemily; Rawson, Jeffrey; Scott, Stephen; Ferreri, Kevin; Mullen, Yoko; El-Shahawy, Mohamed; Dafoe, Donald; Kandeel, Fouad; Al-Abdullah, Ismail H
2015-05-01
We evaluated three commercially available enzymes for pancreatic digestion by comparing key parameters during the islet isolation process, as well as islet quality post-isolation. Retrospectively compared and analyzed islet isolations from pancreata using three different enzyme groups: Liberase HI (n=63), Collagenase NB1/Neutral Protease (NP) (n=43), and Liberase Mammalian Tissue Free Collagenase/Thermolysin (MTF C/T) (n=115). A standardized islet isolation and purification method was used. Islet quality assessment was carried out using islet count, viability, in vitro glucose-stimulated insulin secretion (GSIS), glucose-stimulated oxygen consumption rate (ΔOCR), and in vivo transplantation model in mice. Donor characteristics were not significantly different among the three enzyme groups used in terms of age, sex, hospital stay duration, cause of death, body mass index (BMI), hemoglobin A1c (HbA1c), cold ischemia time (CIT), and pancreas weight. Digestion efficacy (percentage of digested tissue by weight) was significantly higher in the Liberase MTF C/T group (73.5 ± 1.5 %) when compared to the Liberase HI group (63.6 ± 2.3 %) (p<0.001) and the Collagenase NB1/NP group (61.7 ± 2.9%) (p<0.001). The stimulation index for GSIS was significantly higher in the Liberase MTF C/T group (5.3 ± 0.5) as compared to the Liberase HI (2.9 ± 0.2) (p<0.0001) and the Collagenase NB1/NP (3.6 ± 2.9) (p=0.012) groups. Furthermore, the Liberase MTF C/T enzymes showed the highest success rate of transplantation in diabetic NOD Scid mice (65%), which was significantly higher than the Liberase HI (42%, p=0.001) and the Collagenase NB1/NP enzymes (41%, p<0.001). Liberase MTF C/T is superior to Liberase HI and Collagenase NB1/NP in terms of digestion efficacy and glucose-stimulated insulin secretion in vitro . Moreover, Liberase MTF C/T had a significantly higher success rate of transplantation in diabetic NOD Scid mice compared to Liberase HI and Collagenase NB1/NP enzymes.
Image quality analysis of a color LCD as well as a monochrome LCD using a Foveon color CMOS camera
NASA Astrophysics Data System (ADS)
Dallas, William J.; Roehrig, Hans; Krupinski, Elizabeth A.
2007-09-01
We have combined a CMOS color camera with special software to compose a multi-functional image-quality analysis instrument. It functions as a colorimeter as well as measuring modulation transfer functions (MTF) and noise power spectra (NPS). It is presently being expanded to examine fixed-pattern noise and temporal noise. The CMOS camera has 9 μm square pixels and a pixel matrix of 2268 x 1512 x 3. The camera uses a sensor that has co-located pixels for all three primary colors. We have imaged sections of both a color and a monochrome LCD monitor onto the camera sensor with LCD-pixel-size to camera-pixel-size ratios of both 12:1 and 17.6:1. When used as an imaging colorimeter, each camera pixel is calibrated to provide CIE color coordinates and tristimulus values. This capability permits the camera to simultaneously determine chromaticity in different locations on the LCD display. After the color calibration with a CS-200 colorimeter the color coordinates of the display's primaries determined from the camera's luminance response are very close to those found from the CS-200. Only the color coordinates of the display's white point were in error. For calculating the MTF a vertical or horizontal line is displayed on the monitor. The captured image is color-matrix preprocessed, Fourier transformed then post-processed. For NPS, a uniform image is displayed on the monitor. Again, the image is pre-processed, transformed and processed. Our measurements show that the horizontal MTF's of both displays have a larger negative slope than that of the vertical MTF's. This behavior indicates that the horizontal MTF's are poorer than the vertical MTF's. However the modulations at the Nyquist frequency seem lower for the color LCD than for the monochrome LCD. The spatial noise of the color display in both directions is larger than that of the monochrome display. Attempts were also made to analyze the total noise in terms of spatial and temporal noise by applying subtractions of images taken at exactly the same exposure. Temporal noise seems to be significantly lower than spatial noise.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kam, S; Youn, H; Kim, H
2014-06-01
Purpose: To compare and analyze two novel algorithms for the assessment of modulation transfer functions (MTFs) of computed tomography (CT) systems using a simple acrylic cylindrical phantom Method and Materials: Images of the acrylic cylindrical phantom were acquired by a GE LightSpeed 16 RT (GE Healthcare, Milwaukee, WI) using 120 kVp, 330 mA, 2.5 mm slice thickness, 10 cm field-of view (FOV), four reconstruction kernels (e.g. standard, soft, detail, bone, and lung). Two different algorithms were used to analyze images for MTF assessment. First, Richard et al. suggested a task-based MTF assessment method through an edge spread function (ESF) whichmore » described pixel intensities as a function of distance from the center. The MTF was obtained as the absolute value of Fourier transform of the differentiated ESF. Second, Ohkubo et al. devised an effective method to determine the point spread function (PSF) of CT system accompanied with verification. The line spread function (LSF), which was the one-dimensional integration of the PSF, was used to obtain the MTF. We validated the reliability of two above-mentioned methods through the comparison with a conventional method using a thin tungsten wire phantom. Results: The measured MTFs by two methods were mostly similar each other for standard, soft, and detail kernels. In 0.6 lp/mm, the MTF difference between two methods were 0.012(standard), 0.004(soft), and 0.037(detail). They also coincided with the MTF by the conventional method well. However, there were considerable distinctions for bone and lung kernels containing edge enhancement that might cause undershoots near the peak of the LSF. Conclusions: We compared two novel methods to assess task-based MTFs for clinical CT systems especially using a simple acrylic cylindrical phantom with high-convenience and low-cost, and validated them against a conventional method. This work can provide a practical solution to users for the quality assurance of CT.« less
Luzzati, Roberto; Zatta, Marta; Pavan, Nicola; Serafin, Maurizia; Maurel, Cristina; Trombetta, Carlo; Barbone, Fabio
2016-07-01
The burden of human immunodeficiency virus (HIV), hepatitis B virus (HBV), and hepatitis C virus (HCV) infections in transgender population is an underestimated issue. We performed a study to evaluate the prevalence of such infections in transgender persons addressed our center for total sex reassignment surgery (SRS). All transgender persons undergoing SRS from 2000 to 2014 were evaluated retrospectively. Participant characteristics and results of HIV, HBV, and HCV testing were collected. Exact Fisher test, Cochran-Armitage tests for trend and correct prevalence ratios were estimated. Among 498 transgender persons, 243 had confirmed serological data. Of them, 25 were female-to-male and 218 male-to-female (MtF) subjects. The prevalence of HIV, HBV and HCV infections was 0%, 4.0%, and 8.0% in female-to-male, and 12.1%, 4.6%, and 3.7% in MtF. Among MtF, younger age and earlier year of SRS were associated with lower HIV prevalence. From the multivariate model, the mutually adjustment prevalence ratios were 1.9 (95% confidence interval [95% CI], 1.2-3.1) for SRS in 2005-2010 and 3.6 (95% CI, 1.3-9.4) in 2010-2014, as compared with SRS in 2000-2004; and 4.7 (95% CI, 2.4-9.4) for South Americans as compared with others. Among the HCV-positive MtF, 57.1% were also HIV-positive. Regarding HBV, the immunity was 38.5% and, after mutual adjustment, the prevalence ratios were 2.1 (95% CI, 1.3-3.4) for South Americans versus others and 2.2 (95% CI, 1.6-3.1) for year of birth ≥ 1980. The prevalence of HBV and HCV infections among our transgender persons overlaps that reported in the general population, but HCV prevalence was much higher in HIV-infected MtF. The high burden of HIV infection among MtF and its recent incremented prevalence points out that social and medical support should be strongly promoted in such population.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adams, Scott V., E-mail: sadams@fhcrc.org; Barrick, Brian; Christopher, Emily P.
Background: Metallothionein (MT) proteins play critical roles in the physiological handling of both essential (Cu and Zn) and toxic (Cd) metals. MT expression is regulated by metal-regulatory transcription factor 1 (MTF1). Hence, genetic variation in the MT gene family and MTF1 might influence excretion of these metals. Methods: 321 women were recruited in Seattle, WA and Las Cruces, NM and provided demographic information, urine samples for measurement of metal concentrations by mass spectrometry and creatinine, and blood or saliva for extraction of DNA. Forty-one single nucleotide polymorphisms (SNPs) within the MTF1 gene region and the region of chromosome 16 encodingmore » the MT gene family were selected for genotyping in addition to an ancestry informative marker panel. Linear regression was used to estimate the association of SNPs with urinary Cd, Cu, and Zn, adjusted for age, urinary creatinine, smoking history, study site, and ancestry. Results: Minor alleles of rs28366003 and rs10636 near the MT2A gene were associated with lower urinary Cd, Cu, and Zn. Minor alleles of rs8044719 and rs1599823, near MT1A and MT1B, were associated with lower urinary Cd and Zn, respectively. Minor alleles of rs4653329 in MTF1 were associated with lower urinary Cd. Conclusions: These results suggest that genetic variation in the MT gene region and MTF1 influences urinary Cd, Cu, and Zn excretion. - Highlights: • Genetic variation in metallothionein (MT) genes was assessed in two diverse populations. • Single nucleotide polymorphisms (SNPs) in MT genes were associated with mean urinary Cd, Cu and Zn. • Genetic variation may influence biomarkers of exposure, and associations of exposure with health.« less
Dimensional profiles of male to female gender identity disorder: an exploratory research.
Fisher, Alessandra D; Bandini, Elisa; Ricca, Valdo; Ferruccio, Naika; Corona, Giovanni; Meriggiola, Maria C; Jannini, Emmanuele A; Manieri, Chiara; Ristori, Jiska; Forti, Gianni; Mannucci, Edoardo; Maggi, Mario
2010-07-01
Male-to-Female Gender Identity Disorder (MtF GID) is a complex phenomenon that could be better evaluated by using a dimensional approach. To explore the aggregation of clinical manifestations of MtF GID in order to identify meaningful variables describing the heterogeneity of the disorder. A consecutive series of 80 MtF GID subjects (mean age 37 +/- 10.3 years), referred to the Interdepartmental Center for Assistance Gender Identity Disorder of Florence and to other Italian centers from July 2008 to June 2009, was studied. Diagnosis was based on formal psychiatric classification criteria. Factor analysis was performed. Several socio-demographic and clinical parameters were investigated. Patients were asked to complete the Bem Sex Role Inventory (BSRI, a self-rating scale to evaluate gender role) and Symptom Checklist-90 Revised (SCL-90-R, a self-rating scale to measure psychological state). Factor analysis identified two dimensional factors: Factor 1 was associated with sexual orientation, and Factor 2 related to behavioral and psychological correlates of early GID development. No correlation was observed between the two factors. A positive correlation between Factor 2 and feminine BSRI score was found, along with a negative correlation between Factor 2 and undifferentiated BSRI score. Moreover, a significant association between SCL-90-R Phobic subscale score and Factor 2 was observed. A variety of other socio-demographic parameters and clinical features were associated with both factors. Behavioral and psychological correlates of Factor 1 (sexual orientation) and Factor 2 (gender identity) do not constitute the framework of two separate clinical entities, but instead represent two dimensions of the complex MtF GID structure, which can be variably intertwined in the same subject. By using factor analysis, we offer a new approach capable of delineating a psychopathological and clinical profile of MtF GID patients.
Auer, Matthias K; Fuss, Johannes; Stalla, Guenter K; Athanasoulia, Anastasia P
2013-10-01
To demonstrate that adequate pubertal history, physical examination, and a basal hormone profile is sufficient to exclude disorders of sexual development (DSD) in adult transsexuals and that chromosomal analysis could be omitted in cases of unremarkable hormonal profile and pubertal history. Retrospective chart analysis. Endocrine outpatient clinic of a psychiatric research institute. A total of 475 subjects (302 male-to-female transsexuals [MtF], 173 female-to-male transsexuals [FtM]). Data from 323 (192 MtF/131 FtM) were collected for hormonal and pubertal abnormalities. Information regarding chromosomal analysis was available for 270 patients (165 MtF/105 FtM). None. Pubertal abnormalities, menstrual cycle, and hormonal irregularities in relation to chromosomal analysis conducted by karyotype or hair root analysis. In the MtF group, 5.2% of the patients reported pubertal irregularities and 5.7% hormonal abnormalities, and in the FtM group 3.8% and 19.1%, respectively. Overall chromosomal abnormality in both groups was 1.5% (2.9% in the FtM and 0.6% in the MtF group). The aneuploidies found included one gonosomal aneuploidy (45,X[10]/47,XXX[6]/46,XX[98]), two Robertsonian translocations (45,XXder(14;22)(q10;q10)), and one Klinefelter syndrome (47,XXY) that had already been diagnosed in puberty. Our data show a low incidence of chromosomal abnormalities and thus question routine chromosomal analysis at the baseline evaluation of transsexualism, and suggest that it be considered only in cases of abnormal history or hormonal examination. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Comment on Sub-15 nm Hard X-Ray Focusing with a New Total-Reflection Zone Plate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Specht, Eliot D
2011-01-01
Takano et al. report the focusing of 10-keV X-rays to a size of 14.4 nm using a total-reflection zone plate (TRZP). This focal size is at the diffraction limit for the optic's aperture. This would be a noteworthy result, since the TRZP was fabricated using conventional lithography techniques. Alternative nanofocusing optics require more demanding fabrication methods. However, as I will discuss in this Comment, the intensity distribution presented by Takano et al. (Fig. 4 of ref. 1) is more consistent with the random speckle pattern produced by the scattering of a coherent incident beam by a distorted optic than withmore » a diffraction-limited focus. When interpreted in this manner, the true focal spot size is {approx}70 nm: 5 times the diffraction limit. When a coherent photon beam illuminates an optic containing randomly distributed regions which introduce different phase shifts, the scattered diffraction pattern consists of a speckle pattern. Each speckle will be diffraction-limited: the peak width of a single speckle depends entirely on the source coherence and gives no information about the optic. The envelope of the speckle distribution corresponds to the focal spot which would be observed using incoherent illumination. The width of this envelope is due to the finite size of the coherently-diffracting domains produced by slope and position errors in the optic. The focal intensity distribution in Fig. 4 of ref. 1 indeed contains a diffraction-limited peak, but this peak contains only a fraction of the power in the focused, and forms part of a distribution of sharp peaks with an envelope {approx}70 nm in width, just as expected for a speckle pattern. At the 4mm focal distance, the 70 nm width corresponds to a slope error of 18 {micro}rad. To reach the 14 nm diffraction limit, the slope error must be reduced to 3 {micro}rad. Takano et al. have identified a likely source of this error: warping due to stress as a result of zone deposition. It will be interesting to see whether the use of a more rigid substrate gives improved results.« less
The use of interaural parameters during incoherence detection in reproducible noise
NASA Astrophysics Data System (ADS)
Goupell, Matthew Joseph
Interaural incoherence is a measure of the dissimilarity of the signals in the left and right ears. It is important in a number of acoustical phenomenon such as a listener's sensation envelopment and apparent source width in room acoustics, speech intelligibility, and binaural release from energetic masking. Humans are incredibly sensitive to the difference between perfectly coherent and slightly incoherent signals, however the nature of this sensitivity is not well understood. The purpose of this dissertation is to understand what parameters are important to incoherence detection. Incoherence is perceived to have time-varying characteristics. It is conjectured that incoherence detection is performed by a process that takes this time dependency into account. Left-ear-right-ear noise-pairs were generated, all with a fixed value of interaural coherence, 0.9922. The noises had a center frequency of 500 Hz, a bandwidth of 14 Hz, and a duration of 500 ms. Listeners were required to discriminate between these slightly incoherent noises and diotic noises, with a coherence of 1.0. It was found that the value of interaural incoherence itself was an inadequate predictor of discrimination. Instead, incoherence was much more readily detected for those noise-pairs with the largest fluctuations in interaural phase and level differences (as measured by the standard deviation). Noise-pairs with the same value of coherence, and geometric mean frequency of 500 Hz were also generated for bandwidths of 108 Hz and 2394 Hz. It was found that for increasing bandwidth, fluctuations in interaural differences varied less between different noise-pairs and that detection performance varied less as well. The results suggest that incoherence detection is based on the size and the speed of interaural fluctuations and that the value of coherence itself predicts performance only in the wide-band limit where different particular noises with the same incoherence have similar fluctuations. Noise-pairs with short durations of 100, 50, and 25 ms, and bandwidth of 14 Hz, and a coherence of 0.9922 were used to test if a short-term incoherence function is used in incoherence detection. It was found that listeners could significantly use fluctuations of phase and level to detect incoherence for all three of these short durations. Therefore, a short-term coherence function is not used to detect incoherence. For the smallest duration of 25 ms, listeners' detection cue sometimes changed from a "width" cue to a lateralization cue. Modeling of the data was performed. Ten different binaural models were tested against detection data for 14-Hz and 108-Hz bandwidths. These models included different types of binaural processing: independent interaural phase and level differences, lateral position, and short-term cross-correlation. Several preprocessing features were incorporated in the models: compression, temporal averaging, and envelope weighting. For the 14-Hz bandwidth data, the most successful model assumed independent centers for interaural phase and interaural level processing, and this model correlated with detectability at r = 0.87. That model also described the data best when it was assumed that interaural phase fluctuations and interaural level fluctuations contribute approximately equally to incoherence detection. For the 108-Hz bandwidth data, detection performance varied much less among different waveforms, and the data were less able to distinguish between models.
HIV infection risk factors among male-to-female transgender persons: a review of the literature.
De Santis, Joseph P
2009-01-01
Male-to-female (MTF) transgender women experience a host of psychosocial issues such as discrimination, stigmatization, and marginalization. These challenges often limit economic opportunities, affect mental health, and may place members of this population at an increased risk for HIV infection. This report presents a review of the literature that focuses on risk factors for HIV infection specific to the MTF population. Factors including needle sharing and substance abuse, high-risk sexual behaviors, commercial sex work, health care access, lack of knowledge regarding HIV transmission, violence, stigma and discrimination, and mental health issues have been identified in the literature as risk factors for the acquisition of HIV infection by members of this population. Implications for care provided to MTF transgender persons are presented, and suggestions for future research are identified.
Optical image encryption method based on incoherent imaging and polarized light encoding
NASA Astrophysics Data System (ADS)
Wang, Q.; Xiong, D.; Alfalou, A.; Brosseau, C.
2018-05-01
We propose an incoherent encoding system for image encryption based on a polarized encoding method combined with an incoherent imaging. Incoherent imaging is the core component of this proposal, in which the incoherent point-spread function (PSF) of the imaging system serves as the main key to encode the input intensity distribution thanks to a convolution operation. An array of retarders and polarizers is placed on the input plane of the imaging structure to encrypt the polarized state of light based on Mueller polarization calculus. The proposal makes full use of randomness of polarization parameters and incoherent PSF so that a multidimensional key space is generated to deal with illegal attacks. Mueller polarization calculus and incoherent illumination of imaging structure ensure that only intensity information is manipulated. Another key advantage is that complicated processing and recording related to a complex-valued signal are avoided. The encoded information is just an intensity distribution, which is advantageous for data storage and transition because information expansion accompanying conventional encryption methods is also avoided. The decryption procedure can be performed digitally or using optoelectronic devices. Numerical simulation tests demonstrate the validity of the proposed scheme.
NASA Astrophysics Data System (ADS)
Herman, Aline; Sarrazin, Michaël; Deparis, Olivier
2014-01-01
The incoherence of sunlight has long been suspected to have an impact on solar cell energy conversion efficiency, although the extent of this is unclear. Existing computational methods used to optimize solar cell efficiency under incoherent light are based on multiple time-consuming runs and statistical averaging. These indirect methods show limitations related to the complexity of the solar cell structure. As a consequence, complex corrugated cells, which exploit light trapping for enhancing the efficiency, have not yet been accessible for optimization under incoherent light. To overcome this bottleneck, we developed an original direct method which has the key advantage that the treatment of incoherence can be totally decoupled from the complexity of the cell. As an illustration, surface-corrugated GaAs and c-Si thin-films are considered. The spectrally integrated absorption in these devices is found to depend strongly on the degree of light coherence and, accordingly, the maximum achievable photocurrent can be higher under incoherent light than under coherent light. These results show the importance of taking into account sunlight incoherence in solar cell optimization and point out the ability of our direct method to deal with complex solar cell structures.
NASA Astrophysics Data System (ADS)
Vijayakumar, A.; Rosen, Joseph
2017-05-01
Coded aperture correlation holography (COACH) is a recently developed incoherent digital holographic technique. In COACH, two holograms are recorded: the object hologram for the object under study and another hologram for a point object called PSF hologram. The holograms are recorded by interfering two beams, both diffracted from the same object point, but only one of them passes through a random-like coded phase mask (CPM). The same CPM is used for recording the object as well as the PSF holograms. The image is reconstructed by correlating the object hologram with a processed version of the PSF hologram. The COACH holographic technique exhibits the same transverse and axial resolution of the regular imaging, but with the unique capability of storing 3D information. The basic COACH configuration consists of a single spatial light modulator (SLM) used for displaying the CPM. In this study, the basic COACH configuration has been advanced by employing two spatial light modulators (SLMs) in the setup. The refractive lens used in the basic COACH setup for collecting and collimating the light diffracted by the object is replaced by an SLM on which an equivalent diffractive lens is displayed. Unlike a refractive lens, the diffractive lens displayed on the first SLM focuses light with different wavelengths to different axial planes, which are separated by distances larger than the axial correlation lengths of the CPM for any visible wavelength. This characteristic extends the boundaries of COACH from three-dimensional to four-dimensional imaging with the wavelength as its fourth dimension.
1988-06-17
Two difinitions have been devised to quantify contrast. Contrast ratio is given by - L2CR= = L (1) in which L2 and Li are luminance measurements and L2...units, which are quantitative , well understood, and predictable, before the display hardware is built. The last advantage is economically important in...then estimate quantitatively the effect of the resultant MTF change on user performance. 10 The reader interested in probing MTF in further depth is
2011-01-25
The Quadruple Aim: Working Together, Achieving Success 2011 Military Health System Conference Driving change through MTF and market -level assessment...and strategies Tidewater Multi-Service Market Perspectives January 25, 2011 Rear Admiral A. Stocks, MC, USN Colonel E. Stone, MC, USAF...Colonel K. Gausman, NC, USA 1 Military Health System Conference Tidewater Multi-Service Market Report Documentation Page Form ApprovedOMB No. 0704-0188
ERIC Educational Resources Information Center
Johnston, Lloyd D.; O'Malley, Patrick M.; Bachman, Jerald G.; Schulenberg, John E.; Miech, Richard A.
2014-01-01
This occasional paper presents national demographic subgroup trends for U.S. secondary school students in a series of figures and tables. It supplements two of four annual monographs from the Monitoring the Future (MTF) study, namely the "Overview of Key Findings" and "Volume I: Secondary School Students." MTF is funded by the…
Chromatin insulation by a transcriptional activator
Sutter, Nathan B.; Scalzo, David; Fiering, Steven; Groudine, Mark; Martin, David I. K.
2003-01-01
In eukaryotic genomes, transcriptionally active regions are interspersed with silent chromatin that may repress genes in its vicinity. Chromatin insulators are elements that can shield a locus from repressive effects of flanking chromatin. Few such elements have been characterized in higher eukaryotes, but transcriptional activating elements are an invariant feature of active loci and have been shown to suppress transgene silencing. Hence, we have assessed the ability of a transcriptional activator to cause chromatin insulation, i.e., to relieve position effects at transgene integration sites in cultured cells. The transgene contained a series of binding sites for the metal-inducible transcriptional activator MTF, linked to a GFP reporter. Clones carrying single integrated transgenes were derived without selection for expression, and in most clones the transgene was silent. Induction of MTF resulted in transition of the transgene from the silent to the active state, prolongation of the active state, and a marked narrowing of the range of expression levels at different genomic sites. At one genomic site, prolonged induction of MTF resulted in suppression of transgene silencing that persisted after withdrawal of the induction stimulus. These results are consistent with MTF acting as a chromatin insulator and imply that transcriptional activating elements can insulate active loci against chromatin repression. PMID:12547916
Honda, Michitaka
2014-04-01
Several improvements were implemented in the edge method of presampled modulation transfer function measurements (MTFs). The estimation technique for edge angle was newly developed by applying an algorithm for principal components analysis. The error in the estimation was statistically confirmed to be less than 0.01 even in the presence of quantum noise. Secondly, the geometrical edge slope was approximated using a rationalized number, making it possible to obtain an oversampled edge response function (ESF) with equal intervals. Thirdly, the final MTFs were estimated using the average of multiple MTFs calculated for local areas. This averaging operation eliminates the errors caused by the rationalized approximation. Computer-simulated images were used to evaluate the accuracy of our method. The relative error between the estimated MTF and the theoretical MTF at the Nyquist frequency was less than 0.5% when the MTF was expressed as a sinc function. For MTFs representing an indirect detector and phase-contrast detector, good agreement was also observed for the estimated MTFs for each. The high accuracy of the MTF estimation was also confirmed, even for edge angles of around 10 degrees, which suggests the potential for simplification of the measurement conditions. The proposed method could be incorporated into an automated measurement technique using a software application.
Okabe, Nobuyuki; Sato, Toshiki; Matsumoto, Yosuke; Ido, Yumiko; Terada, Seishi; Kuroda, Shigetoshi
2008-01-15
The aim of this study was to examine the clinical characteristics of patients with gender identity disorder (GID) at a GID clinic in Japan. A total of 603 consecutive patients were evaluated at the GID clinic using clinical information and results of physical and neurological examinations. Using DSM-IV criteria, 579 patients (96.0%) were diagnosed with GID. Four patients were excluded for transvestic fetishism, eight for homosexuality, five for schizophrenia, three for personality disorders, and four for other psychiatric disorders. Among the GID patients, 349 (60.3%) were the female-to-male (FTM) type, and 230 (39.7%) were the male-to-female (MTF) type. Almost all FTM-type GID patients started to feel discomfort with their sex before puberty and were sexually attracted to females. The proportion of FTM patients who had experienced marriage as a female was very low, and very few had children. Therefore, FTM-type GID patients seem to be highly homogeneous. On the other hand, various patterns of age at onset and sexual attraction existed among MTF patients. Among the MTF-type GID patients, 28.3% had married as males and 18.7% had sired children. Thus, MTF-type GID patients seem to be more heterogeneous.
One-dimensional MHD simulations of MTF systems with compact toroid targets and spherical liners
NASA Astrophysics Data System (ADS)
Khalzov, Ivan; Zindler, Ryan; Barsky, Sandra; Delage, Michael; Laberge, Michel
2017-10-01
One-dimensional (1D) MHD code is developed in General Fusion (GF) for coupled plasma-liner simulations in magnetized target fusion (MTF) systems. The main goal of these simulations is to search for optimal parameters of MTF reactor, in which spherical liquid metal liner compresses compact toroid plasma. The code uses Lagrangian description for both liner and plasma. The liner is represented as a set of spherical shells with fixed masses while plasma is discretized as a set of nested tori with circular cross sections and fixed number of particles between them. All physical fields are 1D functions of either spherical (liner) or small toroidal (plasma) radius. Motion of liner and plasma shells is calculated self-consistently based on applied forces and equations of state. Magnetic field is determined by 1D profiles of poloidal and toroidal fluxes - they are advected with shells and diffuse according to local resistivity, this also accounts for flux leakage into the liner. Different plasma transport models are implemented, this allows for comparison with ongoing GF experiments. Fusion power calculation is included into the code. We performed a series of parameter scans in order to establish the underlying dependencies of the MTF system and find the optimal reactor design point.
Hubbard, Joanna K.; Potts, Macy A.; Couch, Brian A.
2017-01-01
Assessments represent an important component of undergraduate courses because they affect how students interact with course content and gauge student achievement of course objectives. To make decisions on assessment design, instructors must understand the affordances and limitations of available question formats. Here, we use a crossover experimental design to identify differences in how multiple-true-false (MTF) and free-response (FR) exam questions reveal student thinking regarding specific conceptions. We report that correct response rates correlate across the two formats but that a higher percentage of students provide correct responses for MTF questions. We find that MTF questions reveal a high prevalence of students with mixed (correct and incorrect) conceptions, while FR questions reveal a high prevalence of students with partial (correct and unclear) conceptions. These results suggest that MTF question prompts can direct students to address specific conceptions but obscure nuances in student thinking and may overestimate the frequency of particular conceptions. Conversely, FR questions provide a more authentic portrait of student thinking but may face limitations in their ability to diagnose specific, particularly incorrect, conceptions. We further discuss an intrinsic tension between question structure and diagnostic capacity and how instructors might use multiple formats or hybrid formats to overcome these obstacles. PMID:28450446
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yashchuk, Valeriy V.; Anderson, Erik H.; Barber, Samuel K.
2011-03-14
A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's datamore » processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.« less
Yashchuk, V. V.; Fischer, P. J.; Chan, E. R.; ...
2015-12-09
We present a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) one-dimensional sequences and two-dimensional arrays as an effective method for spectral characterization in the spatial frequency domain of a broad variety of metrology instrumentation, including interferometric microscopes, scatterometers, phase shifting Fizeau interferometers, scanning and transmission electron microscopes, and at this time, x-ray microscopes. The inherent power spectral density of BPR gratings and arrays, which has a deterministic white-noise-like character, allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field of view of an instrument. We demonstrate themore » MTF calibration and resolution characterization over the full field of a transmission soft x-ray microscope using a BPR multilayer (ML) test sample with 2.8 nm fundamental layer thickness. We show that beyond providing a direct measurement of the microscope's MTF, tests with the BPRML sample can be used to fine tune the instrument's focal distance. Finally, our results confirm the universality of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.« less
Imaging quality analysis of multi-channel scanning radiometer
NASA Astrophysics Data System (ADS)
Fan, Hong; Xu, Wujun; Wang, Chengliang
2008-03-01
Multi-channel scanning radiometer, on boarding FY-2 geostationary meteorological satellite, plays a key role in remote sensing because of its wide field of view and continuous multi-spectral images acquirements. It is significant to evaluate image quality after performance parameters of the imaging system are validated. Several methods of evaluating imaging quality are discussed. Of these methods, the most fundamental is the MTF. The MTF of photoelectric scanning remote instrument, in the scanning direction, is the multiplication of optics transfer function (OTF), detector transfer function (DTF) and electronics transfer function (ETF). For image motion compensation, moving speed of scanning mirror should be considered. The optical MTF measurement is performed in both the EAST/WEST and NORTH/SOUTH direction, whose values are used for alignment purposes and are used to determine the general health of the instrument during integration and testing. Imaging systems cannot perfectly reproduce what they see and end up "blurring" the image. Many parts of the imaging system can cause blurring. Among these are the optical elements, the sampling of the detector itself, post-processing, or the earth's atmosphere for systems that image through it. Through theory calculation and actual measurement, it is proved that DTF and ETF are the main factors of system MTF and the imaging quality can satisfy the requirement of instrument design.
Examination of the dental cone-beam CT equipped with flat-panel-detector (FPD)
NASA Astrophysics Data System (ADS)
Ito, Rieko; Fujita, Naotoshi; Kodera, Yoshie
2011-03-01
In dentistry, computed tomography (CT) is essential for diagnosis. Recently, cone-beam CT has come into use. We used an "Alphard 3030" cone-beam CT equipped with an FPD system. This system can obtain fluoroscopic and CT images. Moreover, the Alphard has 4 exposure modes for CT, and each mode has a different field of view (FOV) and voxel size. We examined the image quality of kinetic and CT images obtained using the cone-beam CT system. To evaluate kinetic image quality, we calculated the Wiener spectrum (WS) and modulation transfer function (MTF). We then analyzed the lag images and exposed a phantom. To evaluate CT image quality, we calculated WS and MTF at various places in the FOV and examined the influence of extension of the cone beam X-ray on voxel size. Furthermore, we compared the WS and MTF values of cone-beam CT to those of another CT system. Evaluation of the kinetic images showed that cone-beam CT is sufficient for clinical diagnosis and provides better image quality than the other system tested. However, during exposure of a CT image, the distance from the center influences image quality (especially MTF). Further, differences in voxel size affect image quality. It is therefore necessary to carefully position the region of interest and select an appropriate mode.
NASA Astrophysics Data System (ADS)
Nihill, Kevin J.; Hund, Zachary M.; Muzas, Alberto; Díaz, Cristina; del Cueto, Marcos; Frankcombe, Terry; Plymale, Noah T.; Lewis, Nathan S.; Martín, Fernando; Sibener, S. J.
2016-08-01
Fundamental details concerning the interaction between H2 and CH3-Si(111) have been elucidated by the combination of diffractive scattering experiments and electronic structure and scattering calculations. Rotationally inelastic diffraction (RID) of H2 and D2 from this model hydrocarbon-decorated semiconductor interface has been confirmed for the first time via both time-of-flight and diffraction measurements, with modest j = 0 → 2 RID intensities for H2 compared to the strong RID features observed for D2 over a large range of kinematic scattering conditions along two high-symmetry azimuthal directions. The Debye-Waller model was applied to the thermal attenuation of diffraction peaks, allowing for precise determination of the RID probabilities by accounting for incoherent motion of the CH3-Si(111) surface atoms. The probabilities of rotationally inelastic diffraction of H2 and D2 have been quantitatively evaluated as a function of beam energy and scattering angle, and have been compared with complementary electronic structure and scattering calculations to provide insight into the interaction potential between H2 (D2) and hence the surface charge density distribution. Specifically, a six-dimensional potential energy surface (PES), describing the electronic structure of the H2(D2)/CH3-Si(111) system, has been computed based on interpolation of density functional theory energies. Quantum and classical dynamics simulations have allowed for an assessment of the accuracy of the PES, and subsequently for identification of the features of the PES that serve as classical turning points. A close scrutiny of the PES reveals the highly anisotropic character of the interaction potential at these turning points. This combination of experiment and theory provides new and important details about the interaction of H2 with a hybrid organic-semiconductor interface, which can be used to further investigate energy flow in technologically relevant systems.
Incidental experiences of affective coherence and incoherence influence persuasion.
Huntsinger, Jeffrey R
2013-06-01
When affective experiences are inconsistent with activated evaluative concepts, people experience what is called affective incoherence; when affective experiences are consistent with activated evaluative concepts, people experience affective coherence. The present research asked whether incidental feelings of affective coherence and incoherence would regulate persuasion. Experiences of affective coherence and incoherence were predicted and found to influence the processing of persuasive messages when evoked prior to receipt of such messages (Experiments 1 and 3), and to influence the confidence with which thoughts generated by persuasive messages were held when evoked after presentation of such messages (Experiments 2 and 3). These results extend research on affective coherence and incoherence by showing that they exert a broader impact on cognitive activity than originally assumed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poludniowski, Gavin G.; Evans, Philip M.
2013-04-15
Purpose: Monte Carlo methods based on the Boltzmann transport equation (BTE) have previously been used to model light transport in powdered-phosphor scintillator screens. Physically motivated guesses or, alternatively, the complexities of Mie theory have been used by some authors to provide the necessary inputs of transport parameters. The purpose of Part II of this work is to: (i) validate predictions of modulation transform function (MTF) using the BTE and calculated values of transport parameters, against experimental data published for two Gd{sub 2}O{sub 2}S:Tb screens; (ii) investigate the impact of size-distribution and emission spectrum on Mie predictions of transport parameters; (iii)more » suggest simpler and novel geometrical optics-based models for these parameters and compare to the predictions of Mie theory. A computer code package called phsphr is made available that allows the MTF predictions for the screens modeled to be reproduced and novel screens to be simulated. Methods: The transport parameters of interest are the scattering efficiency (Q{sub sct}), absorption efficiency (Q{sub abs}), and the scatter anisotropy (g). Calculations of these parameters are made using the analytic method of Mie theory, for spherical grains of radii 0.1-5.0 {mu}m. The sensitivity of the transport parameters to emission wavelength is investigated using an emission spectrum representative of that of Gd{sub 2}O{sub 2}S:Tb. The impact of a grain-size distribution in the screen on the parameters is investigated using a Gaussian size-distribution ({sigma}= 1%, 5%, or 10% of mean radius). Two simple and novel alternative models to Mie theory are suggested: a geometrical optics and diffraction model (GODM) and an extension of this (GODM+). Comparisons to measured MTF are made for two commercial screens: Lanex Fast Back and Lanex Fast Front (Eastman Kodak Company, Inc.). Results: The Mie theory predictions of transport parameters were shown to be highly sensitive to both grain size and emission wavelength. For a phosphor screen structure with a distribution in grain sizes and a spectrum of emission, only the average trend of Mie theory is likely to be important. This average behavior is well predicted by the more sophisticated of the geometrical optics models (GODM+) and in approximate agreement for the simplest (GODM). The root-mean-square differences obtained between predicted MTF and experimental measurements, using all three models (GODM, GODM+, Mie), were within 0.03 for both Lanex screens in all cases. This is excellent agreement in view of the uncertainties in screen composition and optical properties. Conclusions: If Mie theory is used for calculating transport parameters for light scattering and absorption in powdered-phosphor screens, care should be taken to average out the fine-structure in the parameter predictions. However, for visible emission wavelengths ({lambda} < 1.0 {mu}m) and grain radii (a > 0.5 {mu}m), geometrical optics models for transport parameters are an alternative to Mie theory. These geometrical optics models are simpler and lead to no substantial loss in accuracy.« less
Optical system analysis for the ground based EXVM
NASA Technical Reports Server (NTRS)
Hillman, L. W.; Chipman, R. A.; Smith, M. H.
1993-01-01
The MSFC's Experimental Vector Magnetograph (EXVM) is an instrument that observes a 4.4 x 8.8 arcmin field of the sun. The transverse and longitudinal components of the surface magnetic field and the line-of-sight velocities of the photospheric gases can be determined from polarimetric and spectral analysis of the 525.02 nm absorption line of Fe 1. The EXVM has been breadboarded and tested in the laboratory. The optics of the EXVM were tested with a point-diffraction (Smartt) interferometer. The 12 inch Cassegrain telescope was found to have 0.20 waves RMS (at 525.02 nm) of aberration. The post-telescope relay optics were nearly diffraction limited on-axis and had about one wave of primary coma as the predominant aberration at full-field. From theoretical modulation transfer function (MTF) curves of known aberrations, it was concluded that the EXVM should attain a maximum spatial resolution of about 0.5 arcseconds. A resolution test target indicated maximum angular resolutions better than 0.6 arcsec on-axis and 0.7 arcsec at full-field-of-view. A 2D inch heliostat (sun-tracking mirror) was used to direct sunlight into the lab and into the EXVM. Solar images obtained were limited by atmospheric seeing effects. During brief moments of good seeing, angular resolutions of about 1 arcsecond were realized with the EXVM.
Murray, Ian J.; Elliott, Sarah L.; Pallikaris, Aris; Werner, John S.; Choi, Stacey; Tahir, Humza J.
2010-01-01
Most of the high-order aberrations of the eye are not circularly symmetric. Hence, while it is well known that human vision is subject to cortically based orientation preference in cell tuning, the optics of the eye might also introduce some orientational anisotropy. We tested this idea by measuring contrast sensitivity at different orientations of sine-wave gratings when viewing through a closed-loop adaptive optics phoropter. Under aberration-corrected conditions, mean contrast sensitivity improved for all observers by a factor of 1.8× to 5×. The detectability of some orientations improved more than others. As expected, this orientation-specific effect varied between individuals. The sensitivity benefits were accurately predicted from MTF model simulations, demonstrating that the observed effects reflected the individual's pattern of high-order aberrations. In one observer, the orientation-specific effects were substantial: an improvement of 8× at one orientation and 2× in another orientation. The experiments confirm that, for conditions that are not diffraction limited, the optics of the eye introduce rotational asymmetry to the luminance distribution on the retina and that this impacts vision, inducing orientational anisotropy. These results suggest that the traditional view of meridional anisotropy having an entirely neural origin may be true for diffraction-limited pupils but that viewing through larger pupils introduces an additional orientation-specific optical component to this phenomenon. PMID:20884505
ERIC Educational Resources Information Center
Johnston, Lloyd D.; O'Malley, Patrick M.; Miech, Richard A.; Bachman, Jerald G.; Schulenberg, John E.
2016-01-01
This occasional paper presents national demographic subgroup data for the 1975-2015 Monitoring the Future (MTF) national survey results on 8th, 10th, and 12th graders' use of drugs, alcohol, and tobacco. MTF is funded by the National Institute on Drug Abuse at the National Institutes of Health under a series of investigator-initiated, competitive…
ERIC Educational Resources Information Center
Johnston, Lloyd D.; O'Malley, Patrick M.; Miech, Richard A.; Bachman, Jerald G.; Schulenberg, John E.
2015-01-01
This occasional paper presents national demographic subgroup data for the 1975-2014 Monitoring the Future (MTF) national survey results on 8th, 10th, and 12th graders' use of drugs, alcohol, and tobacco. MTF is funded by the National Institute on Drug Abuse at the National Institutes of Health under a series of investigator-initiated, competitive…
ERIC Educational Resources Information Center
Johnston, Lloyd D.; O'Malley, Patrick M.; Miech, Richard A.; Bachman, Jerald G.; Schulenberg, John E.
2017-01-01
This occasional paper presents national demographic subgroup data for the 1975-2016 Monitoring the Future (MTF) national survey results on 8th , 10th, and 12th graders' use of drugs, alcohol, and tobacco. MTF is funded by the National Institute on Drug Abuse at the National Institutes of Health under a series of investigator-initiated, competitive…
Using Time-Phased Casualty Estimates to Determine Medical Resupply Requirements
2006-09-18
calculated from the list of tasks. The RSVP-planned MTF laydown would be replaced by the reporting MTF with a known location. One advantage of...Another advantage is the ability to adapt quickly to changing requirements. Supplies that are used at a faster than initially forecast rate will...Officer ( GMO ) Platforms. San Diego, Calif: Naval Health Research Center; 2001. Technical Report No. 01-18. 5. Galarneau MR, Pang G, Konoske PJ
2005-01-01
Summary xxv their knowledge and to train newly arrived providers who rotated in from previous MTF assignments. Patient Education . The provision of... patient education on self- care was one of the weaker components of the implementation activi- ties. Patient behaviors affect the MTFs’ ability to...and severity of asthma exacerbations. Inadequacies in MTF patient education activities were identified, including problems with program design, limited
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheehey, P.T.; Faehl, R.J.; Kirkpatrick, R.C.
1997-12-31
Magnetized Target Fusion (MTF) experiments, in which a preheated and magnetized target plasma is hydrodynamically compressed to fusion conditions, present some challenging computational modeling problems. Recently, joint experiments relevant to MTF (Russian acronym MAGO, for Magnitnoye Obzhatiye, or magnetic compression) have been performed by Los Alamos National Laboratory and the All-Russian Scientific Research Institute of Experimental Physics (VNIIEF). Modeling of target plasmas must accurately predict plasma densities, temperatures, fields, and lifetime; dense plasma interactions with wall materials must be characterized. Modeling of magnetically driven imploding solid liners, for compression of target plasmas, must address issues such as Rayleigh-Taylor instability growthmore » in the presence of material strength, and glide plane-liner interactions. Proposed experiments involving liner-on-plasma compressions to fusion conditions will require integrated target plasma and liner calculations. Detailed comparison of the modeling results with experiment will be presented.« less
Error analysis of the Golay3 optical imaging system.
Wu, Quanying; Fan, Junliu; Wu, Feng; Zhao, Jun; Qian, Lin
2013-05-01
We use aberration theory to derive a generalized pupil function of the Golay3 imaging system when astigmatisms exist in its submirrors. Theoretical analysis and numerical simulation using ZEMAX show that the point spread function (PSF) and the modulation transfer function (MTF) of the Golay3 sparse aperture system have a periodic change when there are piston errors. When the peak-valley value of the wavefront (PV(tilt)) due to the tilt error increases from zero to λ, the PSF and the MTF change significantly, and the change direction is determined by the location of the submirror with the tilt error. When PV(tilt) becomes larger than λ, the PSF and the MTF remain unvaried. We calculate the peaks of the signal-to-noise ratio (PSNR) resulting from the piston and tilt errors according to the Strehl ratio, and show that the PSNR decreases when the errors increase.
Error of the slanted edge method for measuring the modulation transfer function of imaging systems.
Xie, Xufen; Fan, Hongda; Wang, Hongyuan; Wang, Zebin; Zou, Nianyu
2018-03-01
The slanted edge method is a basic approach for measuring the modulation transfer function (MTF) of imaging systems; however, its measurement accuracy is limited in practice. Theoretical analysis of the slanted edge MTF measurement method performed in this paper reveals that inappropriate edge angles and random noise reduce this accuracy. The error caused by edge angles is analyzed using sampling and reconstruction theory. Furthermore, an error model combining noise and edge angles is proposed. We verify the analyses and model with respect to (i) the edge angle, (ii) a statistical analysis of the measurement error, (iii) the full width at half-maximum of a point spread function, and (iv) the error model. The experimental results verify the theoretical findings. This research can be referential for applications of the slanted edge MTF measurement method.
High-MTF hybrid ferroelectric IRFPA
NASA Astrophysics Data System (ADS)
Evans, Scott B.; Hayden, Terrence
1998-07-01
Low cost, uncooled hybrid infrared focal plane arrays (IRFPA's) are in full-scale production at Raytheon Systems Company (RSC), formerly Texas Instruments Defense Systems and Electronics Group. Detectors consist of reticulated ceramic barium strontium titanate (BST) arrays of 320 X 240 pixels on 48.5 micrometer pitch. The principal performance shortcoming of the hybrid arrays has been low MTF due to thermal crosstalk between pixels. In the past two years, significant improvements have been made to increase MTF making hybrids more competitive in performance with monolithic arrays. The improvements are (1) the reduction of the thickness of the IR absorbing layer electrode that maintains electrical continuity and increases thermal isolation between pixels, (2) reduction of the electrical crosstalk from the ROIC, and (3) development of a process to increase the thermal path-length between pixels called 'elevated optical coat.' This paper describes all three activities and their efficacy. Also discussed is the uncooled IRFPA production capability at RSC.
Comparison of analytic and iterative digital tomosynthesis reconstructions for thin slab objects
NASA Astrophysics Data System (ADS)
Yun, J.; Kim, D. W.; Ha, S.; Kim, H. K.
2017-11-01
For digital x-ray tomosynthesis of thin slab objects, we compare the tomographic imaging performances obtained from the filtered backprojection (FBP) and simultaneous algebraic reconstruction (SART) algorithms. The imaging performance includes the in-plane molulation-transfer function (MTF), the signal difference-to-noise ratio (SDNR), and the out-of-plane blur artifact or artifact-spread function (ASF). The MTF is measured using a thin tungsten-wire phantom, and the SDNR and the ASF are measured using a thin aluminum-disc phantom embedded in a plastic cylinder. The FBP shows a better MTF performance than the SART. On the contrary, the SART outperforms the FBP with regard to the SDNR and ASF performances. Detailed experimental results and their analysis results are described in this paper. For a more proper use of digital tomosynthesis technique, this study suggests to use a reconstuction algorithm suitable for application-specific purposes.
Lam, Kuen; Leung, Man Fuk; Kwan, Chi Wai; Kwan, Joseph
2016-11-01
The study aimed to examine the epidemiology of hypertonic contractures and its relationship with minimal trauma fracture (MTF), and to determine the incidence and predictors of (MTF) in long-term care residents. This was a longitudinal cohort study of prospectively collected data. Participants were followed from March 2007 to March 2016 or until death. A 300-bed long-term care hospital in Hong Kong. All long-term care residents who were in need of continuous medical and nursing care for their activities of daily living. Information on patients' demographic data, severe contracture defined as a decrease of 50% or more of the normal passive range of joint movement of the joint, and severe limb spasticity defined by the Modified Ashworth Scale higher than grade 3, medical comorbidities, functional status, cognitive status, nutritional status including body mass index and serum albumin, past history of fractures, were evaluated as potential risk factors for subsequent MTF. Three hundred ninety-six residents [148 males, mean ± standard deviation (SD), age = 79 ± 16 years] were included for analysis. The presence of severe contracture was highly prevalent among the study population: 91% of residents had at least 1 severe contracture, and 41% of residents had severe contractures involving all 4 limbs. Moreover, there were a significant proportion of residents who had severe limb spasticity with the elbow flexors (32.4%) and knee flexors (33.9%) being the most commonly involved muscles. Twelve residents (3%) suffered from subsequent MTF over a median follow-up of 33 (SD = 30) months. Seven out of these 12 residents died during the follow-up period, with a mean survival of 17.8 months (SD = 12.6) after the fracture event. The following 2 factors were found to independently predict subsequent MTF in a multivariate Cox regression: bilateral severe spastic knee contractures (hazard ratio = 16.5, P < .0001, confidence interval 4.8-56.4) and diabetes mellitus (hazard ratio = 4.0. P = .018, confidence interval 1.3-12.7). Severe spasticity and contractures are common morbidities in long-term care residents, and bilateral severe spastic knee contractures and diabetes mellitus are 2 independent predictors of subsequent MTF. Spasticity management and prevention of contractures, combined with educational programs for caregivers to identify the high-risk residents and apply proper handling techniques during routine care, may be helpful in reducing the risk of MTF in long-term care residents. Further large-scale longitudinal studies are needed to confirm these findings. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.
Optical hiding with visual cryptography
NASA Astrophysics Data System (ADS)
Shi, Yishi; Yang, Xiubo
2017-11-01
We propose an optical hiding method based on visual cryptography. In the hiding process, we convert the secret information into a set of fabricated phase-keys, which are completely independent of each other, intensity-detected-proof and image-covered, leading to the high security. During the extraction process, the covered phase-keys are illuminated with laser beams and then incoherently superimposed to extract the hidden information directly by human vision, without complicated optical implementations and any additional computation, resulting in the convenience of extraction. Also, the phase-keys are manufactured as the diffractive optical elements that are robust to the attacks, such as the blocking and the phase-noise. Optical experiments verify that the high security, the easy extraction and the strong robustness are all obtainable in the visual-cryptography-based optical hiding.
Evidence for the onset of color transparency in ρ 0 electroproduction off nuclei
Guo, L.; Hanretty, C.; Hicks, K.; ...
2012-05-11
We have measured the nuclear transparency of the incoherent diffractive A(e,e'ρ 0) process in 12C and 56Fe targets relative to 2H using a 5 GeV electron beam. The nuclear transparency, the ratio of the produced {rho}{sup 0}'s on a nucleus relative to deuterium, which is sensitive to ρA interaction, was studied as function of the coherence length (I c), a lifetime of the hadronic fluctuation of the virtual photon, and the four-momentum transfer squared (Q 2). Thus, while the transparency for both 12C and 56Fe showed no I c dependence, a significant Q 2 dependence was measured, which is consistentmore » with calculations that included the color transparency effects.« less
Beckers, Jacques M; Andersen, Torben E; Owner-Petersen, Mette
2007-03-05
Under seeing limited conditions very high resolution spectroscopy becomes very difficult for extremely large telescopes (ELTs). Using adaptive optics (AO) the stellar image size decreases proportional with the telescope diameter. This makes the spectrograph optics and hence its resolution independent of the telescope diameter. However AO for use with ELTs at visible wavelengths require deformable mirrors with many elements. Those are not likely to be available for quite some time. We propose to use the pupil slicing technique to create a number of sub-pupils each of which having its own deformable mirror. The images from all sub-pupils are combined incoherently with a diameter corresponding to the diffraction limit of the sub-pupil. The technique is referred to as "Pupil Slicing Adaptive Optics" or PSAO.
Optical system design of dynamic infrared scene projector based on DMD
NASA Astrophysics Data System (ADS)
Lu, Jing; Fu, Yuegang; Liu, Zhiying; Li, Yandong
2014-09-01
Infrared scene simulator is now widely used to simulate infrared scene practicality in the laboratory, which can greatly reduce the research cost of the optical electrical system and offer economical experiment environment. With the advantage of large dynamic range and high spatial resolution, dynamic infrared projection technology, which is the key part of the infrared scene simulator, based on digital micro-mirror device (DMD) has been rapidly developed and widely applied in recent years. In this paper, the principle of the digital micro-mirror device is briefly introduced and the characteristics of the DLP (Digital Light Procession) system based on digital micromirror device (DMD) are analyzed. The projection system worked at 8~12μm with 1024×768 pixel DMD is designed by ZEMAX. The MTF curve is close to the diffraction limited curve and the radius of the spot diagram is smaller than that of the airy disk. The result indicates that the system meets the design requirements.
The Precautionary Principle Has Not Been Shown to Be Incoherent: A Reply to Peterson.
Boyer-Kassem, Thomas
2017-11-01
In this journal, I have objected to Peterson's 2006 claim that the precautionary principle is an incoherent decision rule. I defend my objections to Peterson's recent replies, and I still claim that the precautionary principle has not been shown to be incoherent. © 2017 Society for Risk Analysis.
Optics and optics-based technologies education with the benefit of LabVIEW
NASA Astrophysics Data System (ADS)
Wan, Yuhong; Man, Tianlong; Tao, Shiquan
2015-10-01
The details of design and implementation of incoherent digital holographic experiments based on LabVIEW are demonstrated in this work in order to offer a teaching modal by making full use of LabVIEW as an educational tool. Digital incoherent holography enables holograms to be recorded from incoherent light with just a digital camera and spatial light modulator and three-dimensional properties of the specimen are revealed after the hologram is reconstructed in the computer. The experiment of phase shifting incoherent digital holography is designed and implemented based on the principle of Fresnel incoherent correlation holography. An automatic control application is developed based on LabVIEW, which combines the functions of major experimental hardware control and digital reconstruction of the holograms. The basic functions of the system are completed and a user-friendly interface is provided for easy operation. The students are encouraged and stimulated to learn and practice the basic principle of incoherent digital holography and other related optics-based technologies during the programming of the application and implementation of the system.
LCD displays performance comparison by MTF measurement using the white noise stimulus method
NASA Astrophysics Data System (ADS)
Mitjà, Carles; Escofet, Jaume
2011-01-01
The amount of images produced to be viewed as soft copies on output displays are significantly increasing. This growing occurs at the expense of the images targeted to hard copy versions on paper or any other physical support. Even in the case of high quality hard copy production, people working in professional imaging uses different displays in selecting, editing, processing and showing images, from laptop screen to specialized high end displays. Then, the quality performance of these devices is crucial in the chain of decisions to be taken in image production. Metrics of this quality performance can help in the equipment acquisition. Different metrics and methods have been described to determine the quality performance of CRT and LCD computer displays in clinical area. One of most important metrics in this field is the device spatial frequency response obtained measuring the modulation transfer function (MTF). This work presents a comparison between the MTF of three different LCD displays, Apple MacBook Pro 15", Apple LED Cinema Display 24" and Apple iPhone4, measured by the white noise stimulus method, over vertical and horizontal directions. Additionally, different displays show particular pixels structure pattern. In order to identify this pixel structure, a set of high magnification images is taken from each display to be related with the respective vertical and horizontal MTF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yashchuk, Valeriy V; Anderson, Erik H.; Barber, Samuel K.
2010-07-26
A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument'smore » data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.« less
The Progress of Research Project for Magnetized Target Fusion in China
NASA Astrophysics Data System (ADS)
Yang, Xian-Jun
2015-11-01
The fusion of magnetized plasma called Magnetized Target Fusion (MTF) is a hot research area recently. It may significantly reduce the cost and size. Great progress has been achieved in past decades around the world. Five years ago, China initiated the MTF project and has gotten some progress as follows: 1. Verifying the feasibility of ignition of MTF by means of first principle and MHD simulation; 2. Generating the magnetic field over 1400 Tesla, which can be suppress the heat conduction from charged particles, deposit the energy of alpha particle to promote the ignition process, and produce the stable magnetized plasma for the target of ignition; 3. The imploding facility of FP-1 can put several Mega Joule energy to the solid liner of about ten gram in the range of microsecond risen time, while the simulating tool has been developed for design and analysis of the process; 4. The target of FRC can be generated by ``YG 1 facility'' while some simulating tools have be developed. Next five years, the above theoretical work and the experiments of MTF may be integrated to step up as the National project, which may make my term play an important lead role and be supposed to achieve farther progress in China. Supported by the National Natural Science Foundation of China under Grant No 11175028.
Preliminary display comparison for dental diagnostic applications
NASA Astrophysics Data System (ADS)
Odlum, Nicholas; Spalla, Guillaume; van Assche, Nele; Vandenberghe, Bart; Jacobs, Reinhilde; Quirynen, Marc; Marchessoux, Cédric
2012-02-01
The aim of this study is to predict the clinical performance and image quality of a display system for viewing dental images. At present, the use of dedicated medical displays is not uniform among dentists - many still view images on ordinary consumer displays. This work investigated whether the use of a medical display improved the perception of dental images by a clinician, compared to a consumer display. Display systems were simulated using the MEdical Virtual Imaging Chain (MEVIC). Images derived from two carefully performed studies on periodontal bone lesion detection and endodontic file length determination, were used. Three displays were selected: a medical grade one and two consumer displays (Barco MDRC-2120, Dell 1907FP and Dell 2007FPb). Some typical characteristics of the displays are evaluated by measurements and simulations like the Modulation Function (MTF), the Noise Power Spectrum (NPS), backlight stability or calibration. For the MTF, the display with the largest pixel pitch has logically the worst MTF. Moreover, the medical grade display has a slightly better MTF and the displays have similar NPS. The study shows the instability effect for the emitted intensity of the consumer displays compared to the medical grade one. Finally the study on the calibration methodology of the display shows that the signal in the dental images will be always more perceivable on the DICOM GSDF display than a gamma 2,2 display.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunter, David M.; Belev, Gueorgi; DeCrescenzo, Giovanni
2007-08-15
Blocking layers are used to reduce leakage current in amorphous selenium detectors. The effect of the thickness of the blocking layer on the presampling modulation transfer function (MTF) and on dark current was experimentally determined in prototype single-line CCD-based amorphous selenium (a-Se) x-ray detectors. The sampling pitch of the detectors evaluated was 25 {mu}m and the blocking layer thicknesses varied from 1 to 51 {mu}m. The blocking layers resided on the signal collection electrodes which, in this configuration, were used to collect electrons. The combined thickness of the blocking layer and a-Se bulk in each detector was {approx}200 {mu}m. Asmore » expected, the dark current increased monotonically as the thickness of the blocking layer was decreased. It was found that if the blocking layer thickness was small compared to the sampling pitch, it caused a negligible reduction in MTF. However, the MTF was observed to decrease dramatically at spatial frequencies near the Nyquist frequency as the blocking layer thickness approached or exceeded the electrode sampling pitch. This observed reduction in MTF is shown to be consistent with predictions of an electrostatic model wherein the image charge from the a-Se is trapped at a characteristic depth within the blocking layer, generally near the interface between the blocking layer and the a-Se bulk.« less
Yoon, Chun Hong; Yurkov, Mikhail V.; Schneidmiller, Evgeny A.; Samoylova, Liubov; Buzmakov, Alexey; Jurek, Zoltan; Ziaja, Beata; Santra, Robin; Loh, N. Duane; Tschentscher, Thomas; Mancuso, Adrian P.
2016-01-01
The advent of newer, brighter, and more coherent X-ray sources, such as X-ray Free-Electron Lasers (XFELs), represents a tremendous growth in the potential to apply coherent X-rays to determine the structure of materials from the micron-scale down to the Angstrom-scale. There is a significant need for a multi-physics simulation framework to perform source-to-detector simulations for a single particle imaging experiment, including (i) the multidimensional simulation of the X-ray source; (ii) simulation of the wave-optics propagation of the coherent XFEL beams; (iii) atomistic modelling of photon-material interactions; (iv) simulation of the time-dependent diffraction process, including incoherent scattering; (v) assembling noisy and incomplete diffraction intensities into a three-dimensional data set using the Expansion-Maximisation-Compression (EMC) algorithm and (vi) phase retrieval to obtain structural information. We demonstrate the framework by simulating a single-particle experiment for a nitrogenase iron protein using parameters of the SPB/SFX instrument of the European XFEL. This exercise demonstrably yields interpretable consequences for structure determination that are crucial yet currently unavailable for experiment design. PMID:27109208
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoon, Chun Hong; Yurkov, Mikhail V.; Schneidmiller, Evgeny A.
The advent of newer, brighter, and more coherent X-ray sources, such as X-ray Free-Electron Lasers (XFELs), represents a tremendous growth in the potential to apply coherent X-rays to determine the structure of materials from the micron-scale down to the Angstrom-scale. There is a significant need for a multi-physics simulation framework to perform source-to-detector simulations for a single particle imaging experiment, including (i) the multidimensional simulation of the X-ray source; (ii) simulation of the wave-optics propagation of the coherent XFEL beams; (iii) atomistic modelling of photon-material interactions; (iv) simulation of the time-dependent diffraction process, including incoherent scattering; (v) assembling noisy andmore » incomplete diffraction intensities into a three-dimensional data set using the Expansion-Maximisation-Compression (EMC) algorithm and (vi) phase retrieval to obtain structural information. Furthermore, we demonstrate the framework by simulating a single-particle experiment for a nitrogenase iron protein using parameters of the SPB/SFX instrument of the European XFEL. This exercise demonstrably yields interpretable consequences for structure determination that are crucial yet currently unavailable for experiment design.« less
Yoon, Chun Hong; Yurkov, Mikhail V.; Schneidmiller, Evgeny A.; ...
2016-04-25
The advent of newer, brighter, and more coherent X-ray sources, such as X-ray Free-Electron Lasers (XFELs), represents a tremendous growth in the potential to apply coherent X-rays to determine the structure of materials from the micron-scale down to the Angstrom-scale. There is a significant need for a multi-physics simulation framework to perform source-to-detector simulations for a single particle imaging experiment, including (i) the multidimensional simulation of the X-ray source; (ii) simulation of the wave-optics propagation of the coherent XFEL beams; (iii) atomistic modelling of photon-material interactions; (iv) simulation of the time-dependent diffraction process, including incoherent scattering; (v) assembling noisy andmore » incomplete diffraction intensities into a three-dimensional data set using the Expansion-Maximisation-Compression (EMC) algorithm and (vi) phase retrieval to obtain structural information. Furthermore, we demonstrate the framework by simulating a single-particle experiment for a nitrogenase iron protein using parameters of the SPB/SFX instrument of the European XFEL. This exercise demonstrably yields interpretable consequences for structure determination that are crucial yet currently unavailable for experiment design.« less
Collective Effects in a Diffraction Limited Storage Ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nagaoka, Ryutaro; Bane, Karl L.F.
Our paper gives an overview of collective effects that are likely to appear and possibly limit the performance in a diffraction-limited storage ring (DLSR) that stores a high-intensity ultra-low-emittance beam. Beam instabilities and other intensity-dependent effects that may significantly impact the machine performance are covered. The latter include beam-induced machine heating, Touschek scattering, intra-beam scattering, as well as incoherent tune shifts. The general trend that the efforts to achieve ultra-low emittance result in increasing the machine coupling impedance and the beam sensitivity to instability is reviewed. The nature of coupling impedance in a DLSR is described, followed by a seriesmore » of potentially dangerous beam instabilities driven by the former, such as resistive-wall, TMCI (transverse mode coupling instability), head-tail and microwave instabilities. Additionally, beam-ion and CSR (coherent synchrotron radiation) instabilities are also treated. Means to fight against collective effects such as lengthening of the bunch with passive harmonic cavities and bunch-by-bunch transverse feedback are introduced. Numerical codes developed and used to evaluate the machine coupling impedance, as well as to simulate beam instability using the former as inputs are described.« less
In situ electron backscatter diffraction investigation of recrystallization in a copper wire.
Brisset, François; Helbert, Anne-Laure; Baudin, Thierry
2013-08-01
The microstructural evolution of a cold drawn copper wire (reduction area of 38%) during primary recrystallization and grain growth was observed in situ by electron backscatter diffraction. Two thermal treatments were performed, and successive scans were acquired on samples undergoing heating from ambient temperature to a steady state of 200°C or 215°C. During a third in situ annealing, the temperature was continuously increased up to 600°C. Nuclei were observed to grow at the expense of the deformed microstructure. This growth was enhanced by the high stored energy difference between the nuclei and their neighbors (driving energy in recrystallization) and by the presence of high-angle grain boundaries of high mobility. In the early stages of growth, the nuclei twin and the newly created orientations continue to grow to the detriment of the strained copper. At high temperatures, the disappearance of some twins was evidenced by the migration of the incoherent twin boundaries. Thermal grooving of grain boundaries is observed at these high temperatures and affects the high mobile boundaries but tends to preserve the twin boundaries of lower energy. Thus, grooving may contribute to the twin vanishing.
Collective Effects in a Diffraction Limited Storage Ring
Nagaoka, Ryutaro; Bane, Karl L.F.
2015-10-20
Our paper gives an overview of collective effects that are likely to appear and possibly limit the performance in a diffraction-limited storage ring (DLSR) that stores a high-intensity ultra-low-emittance beam. Beam instabilities and other intensity-dependent effects that may significantly impact the machine performance are covered. The latter include beam-induced machine heating, Touschek scattering, intra-beam scattering, as well as incoherent tune shifts. The general trend that the efforts to achieve ultra-low emittance result in increasing the machine coupling impedance and the beam sensitivity to instability is reviewed. The nature of coupling impedance in a DLSR is described, followed by a seriesmore » of potentially dangerous beam instabilities driven by the former, such as resistive-wall, TMCI (transverse mode coupling instability), head-tail and microwave instabilities. Additionally, beam-ion and CSR (coherent synchrotron radiation) instabilities are also treated. Means to fight against collective effects such as lengthening of the bunch with passive harmonic cavities and bunch-by-bunch transverse feedback are introduced. Numerical codes developed and used to evaluate the machine coupling impedance, as well as to simulate beam instability using the former as inputs are described.« less
Spin-analyzed SANS for soft matter applications
NASA Astrophysics Data System (ADS)
Chen, W. C.; Barker, J. G.; Jones, R.; Krycka, K. L.; Watson, S. M.; Gagnon, C.; Perevozchivoka, T.; Butler, P.; Gentile, T. R.
2017-06-01
The small angle neutron scattering (SANS) of nearly Q-independent nuclear spin-incoherent scattering from hydrogen present in most soft matter and biology samples may raise an issue in structure determination in certain soft matter applications. This is true at high wave vector transfer Q where coherent scattering is much weaker than the nearly Q-independent spin-incoherent scattering background. Polarization analysis is capable of separating coherent scattering from spin-incoherent scattering, hence potentially removing the nearly Q-independent background. Here we demonstrate SANS polarization analysis in conjunction with the time-of-flight technique for separation of coherent and nuclear spin-incoherent scattering for a sample of silver behenate back-filled with light water. We describe a complete procedure for SANS polarization analysis for separating coherent from incoherent scattering for soft matter samples that show inelastic scattering. Polarization efficiency correction and subsequent separation of the coherent and incoherent scattering have been done with and without a time-of-flight technique for direct comparisons. In addition, we have accounted for the effect of multiple scattering from light water to determine the contribution of nuclear spin-incoherent scattering in both the spin flip channel and non-spin flip channel when performing SANS polarization analysis. We discuss the possible gain in the signal-to-noise ratio for the measured coherent scattering signal using polarization analysis with the time-of-flight technique compared with routine unpolarized SANS measurements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scaduto, DA; Hu, Y-H; Zhao, W
Purpose: Spatial resolution in digital breast tomosynthesis (DBT) is affected by inherent/binned detector resolution, oblique entry of x-rays, and focal spot size/motion; the limited angular range further limits spatial resolution in the depth-direction. While DBT is being widely adopted clinically, imaging performance metrics and quality control protocols have not been standardized. AAPM Task Group 245 on Tomosynthesis Quality Control has been formed to address this deficiency. Methods: Methods of measuring spatial resolution are evaluated using two prototype quality control phantoms for DBT. Spatial resolution in the detector plane is measured in projection and reconstruction domains using edge-spread function (ESF), point-spreadmore » function (PSF) and modulation transfer function (MTF). Spatial resolution in the depth-direction and effective slice thickness are measured in the reconstruction domain using slice sensitivity profile (SSP) and artifact spread function (ASF). An oversampled PSF in the depth-direction is measured using a 50 µm angulated tungsten wire, from which the MTF is computed. Object-dependent PSF is derived and compared with ASF. Sensitivity of these measurements to phantom positioning, imaging conditions and reconstruction algorithms is evaluated. Results are compared from systems of varying acquisition geometry (9–25 projections over 15–60°). Dependence of measurements on feature size is investigated. Results: Measurements of spatial resolution using PSF and LSF are shown to depend on feature size; depth-direction spatial resolution measurements are shown to similarly depend on feature size for ASF, though deconvolution with an object function removes feature size-dependence. A slanted wire may be used to measure oversampled PSFs, from which MTFs may be computed for both in-plane and depth-direction resolution. Conclusion: Spatial resolution measured using PSF is object-independent with sufficiently small object; MTF is object-independent. Depth-direction spatial resolution may be measured directly using MTF or indirectly using ASF or SSP as surrogate measurements. While MTF is object-independent, it is invalid for nonlinear reconstructions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bache, S; Rong, J
Purpose: To quantify a radiology team’s assessment of image quality differences between two CT scanner models currently in clinical use, with emphasis on spatial resolution that could be impacted by focal spot size. Methods: Modulation Transfer Functions (MTF) measurements were performed by scanning the impulse source insert module of the Catphan 600 at 120/140 kVp with both large (LFS) and small (SFS) focal spots and reconstructed to 2.5mm and 5.0mm thicknesses on a GE Discovery CT750 HD and a LightSpeed VCT CT scanner. MTFs were calculated by summing the 2D PSF along one-dimension to obtain line-spread-function (LSF), and calculating themore » Fourier Transform of the zero-padded and background corrected LSF. Spatial resolution performance was evaluated by comparing MTF curves, 50% and 10% MTF cutoff, and total area under the MTF curve (AUC). In addition, images of the Catphan high-contrast module and a Kagaku anthropomorphic body phantom were acquired from the HD scanner for visual comparisons. Results: For each scanner model, SFS was superior to LFS spatial resolution with respect to 50%/10% MTF cutoff and AUC. For the HD, 50%/10% cutoff was 4.29/7.22cm-1 for the LFS and 4.43/7.45cm-1 for the SFS. VCT outperformed HD, with 50%/10% cutoff of 4.40/7.29 cm-1 for LFS and 4.62/7.47cm-1 for SFS. Scanner model performance in order of decreasing AUC performance was VCT SFS (7.43), HD SFS (7.20), VCT LFS (7.09) and HD LFS (6.93). Visual evaluations of Kagaku phantom images confirmed that VCT outperformed HD. Conclusion: VCT outperformed HD and small focal spot is desired for either model over large focal spot in term of spatial resolution – in agreement with radiologist feedback of overall image quality. In-depth evaluations of clinical impact and focal spot selection mechanisms is currently being assessed.« less
Transgender transitioning and change of self-reported sexual orientation.
Auer, Matthias K; Fuss, Johannes; Höhne, Nina; Stalla, Günter K; Sievers, Caroline
2014-01-01
Sexual orientation is usually considered to be determined in early life and stable in the course of adulthood. In contrast, some transgender individuals report a change in sexual orientation. A common reason for this phenomenon is not known. We included 115 transsexual persons (70 male-to-female "MtF" and 45 female-to-male "FtM") patients from our endocrine outpatient clinic, who completed a questionnaire, retrospectively evaluating the history of their gender transition phase. The questionnaire focused on sexual orientation and recalled time points of changes in sexual orientation in the context of transition. Participants were further asked to provide a personal concept for a potential change in sexual orientation. In total, 32.9% (n = 23) MtF reported a change in sexual orientation in contrast to 22.2% (n = 10) FtM transsexual persons (p = 0.132). Out of these patients, 39.1% (MtF) and 60% (FtM) reported a change in sexual orientation before having undergone any sex reassignment surgery. FtM that had initially been sexually oriented towards males ( = androphilic), were significantly more likely to report on a change in sexual orientation than gynephilic, analloerotic or bisexual FtM (p = 0.012). Similarly, gynephilic MtF reported a change in sexual orientation more frequently than androphilic, analloerotic or bisexual MtF transsexual persons (p =0.05). In line with earlier reports, we reveal that a change in self-reported sexual orientation is frequent and does not solely occur in the context of particular transition events. Transsexual persons that are attracted by individuals of the opposite biological sex are more likely to change sexual orientation. Qualitative reports suggest that the individual's biography, autogynephilic and autoandrophilic sexual arousal, confusion before and after transitioning, social and self-acceptance, as well as concept of sexual orientation itself may explain this phenomenon.
Impact of Sexual Orientation Identity on Medical Morbidities in Male-to-Female Transgender Patients.
Gaither, Thomas W; Awad, Mohannad A; Osterberg, E Charles; Romero, Angelita; Bowers, Marci L; Breyer, Benjamin N
2017-02-01
We aim to describe the relationship between sexual orientation identity and medical morbidities in a large sample of male-to-female (MTF) transgender patients. We reviewed medical records of patients presenting for MTF sex reassignment surgery (SRS) by a single, high-volume surgeon from 2011 to 2015. Sexual attraction to men (heterosexual), women (lesbian), or both (bisexual) was asked of each patient. We examined 16 medical morbidities for this analysis. During the study period, 330 MTF transgender patients presented for SRS. The average age at the time of surgery was 38.9 (range 18-76). One hundred and one patients (32%) reported being heterosexual, 110 patients (34%) reported being lesbian, and 108 patients (34%) reported being bisexual. Lesbian patients presented for SRS at older ages (mean = 43 years old) compared with heterosexual patients (mean = 36 years old) and bisexual patients (mean = 37), P < 0.01. No differences were found in the majority of coexisting medical morbidities by sexual orientation identity. Lesbian patients had greater odds of having a history of depression, age-adjusted odds ratio (aOR) = 2.36, 95% confidence interval (CI) 1.26-4.40, compared with heterosexual patients. Lesbian patients had higher odds of being married or partnered, aOR = 2.31, 95% CI (1.27-4.19), compared with heterosexual patients. Heterosexual patients had higher odds of having human immunodeficiency virus (HIV), aOR = 9.07, 95% CI (1.08-76.5) compared with lesbian patients. Sexual orientation identity in MTF transgender patients is variable. The majority of medical morbidities are not associated with sexual orientation identity. Although HIV and depression are common morbidities among MTF patients seeking SRS, the prevalence of these morbidities differs by sexual orientation identity, but these findings need replication. Counseling and future research initiatives in transgender care should incorporate sexual orientation identity and associated risk behavior.
Ganesh, Sri; Brar, Sheetal; Pandey, Rahul; Pawar, Archana
2018-01-01
Purpose: To study the time course of interface healing and its correlation with visual acuity, modulation transfer function (MTF), and aberrations after myopic small-incision lenticule extraction (SMILE) correction. Methods: Seventy-eight eyes of 78 patients (1 eye per patient) with a mean age of 25.7 years and mean spherical equivalent (SE) of −3.74D, undergoing bilateral SMILE procedure, were included in this study. On postoperative day 1, 2 weeks, and 3 months, dilated retroillumination photographs were taken and morphology of corneal interface was graded by comparing them with 5 standard templates representing 5 grades of interface roughness (IRG): IRG – 0 (clear), IRG – 1 (mild), IRG – 2 (moderate), IRG – 3 (severe), and IRG – 4 (severe IRG with Bowman's folds in visual axis). Pearson's correlations were computed to study correlation associations, and Wilcoxon signed-rank test was used for intragroup comparison of means. P ≤ 0.05 was considered statistically significant. Results: At 3 months, 90.70% eyes were Grade 0 while 9.30% eyes still had Grade 2 interface granularity. Mean IRG significantly improved from 2.47 ± 0.57 at day 1 to 0.62 ± 0.53 at 3 months (P = 0.00). At day 1, pre-SE showed a significant positive correlation with IRG; however, mean postoperative corrected distant visual acuity (CDVA, in decimal), corneal Strehl ratio (SR), and MTF showed weak but significant negative correlation with IRG (r2 = 0.28 for SE, −0.052 for CDVA, −0.017 for SR, and −0.39 for MTF, respectively, P < 0.05 for all correlations). At 2 weeks and 3 months, corneal MTF continued to show a significant negative correlation, whereas other parameters did not show any correlation with IRG. Conclusion: Visual quality and corneal MTF may be significantly affected by the IRG in the immediate postoperative period after SMILE and may take 3 months or more for complete recovery. PMID:29380760
Ganesh, Sri; Brar, Sheetal; Pandey, Rahul; Pawar, Archana
2018-02-01
To study the time course of interface healing and its correlation with visual acuity, modulation transfer function (MTF), and aberrations after myopic small-incision lenticule extraction (SMILE) correction. Seventy-eight eyes of 78 patients (1 eye per patient) with a mean age of 25.7 years and mean spherical equivalent (SE) of -3.74D, undergoing bilateral SMILE procedure, were included in this study. On postoperative day 1, 2 weeks, and 3 months, dilated retroillumination photographs were taken and morphology of corneal interface was graded by comparing them with 5 standard templates representing 5 grades of interface roughness (IRG): IRG - 0 (clear), IRG - 1 (mild), IRG - 2 (moderate), IRG - 3 (severe), and IRG - 4 (severe IRG with Bowman's folds in visual axis). Pearson's correlations were computed to study correlation associations, and Wilcoxon signed-rank test was used for intragroup comparison of means. P ≤ 0.05 was considered statistically significant. At 3 months, 90.70% eyes were Grade 0 while 9.30% eyes still had Grade 2 interface granularity. Mean IRG significantly improved from 2.47 ± 0.57 at day 1 to 0.62 ± 0.53 at 3 months (P = 0.00). At day 1, pre-SE showed a significant positive correlation with IRG; however, mean postoperative corrected distant visual acuity (CDVA, in decimal), corneal Strehl ratio (SR), and MTF showed weak but significant negative correlation with IRG (r2 = 0.28 for SE, -0.052 for CDVA, -0.017 for SR, and -0.39 for MTF, respectively, P < 0.05 for all correlations). At 2 weeks and 3 months, corneal MTF continued to show a significant negative correlation, whereas other parameters did not show any correlation with IRG. Visual quality and corneal MTF may be significantly affected by the IRG in the immediate postoperative period after SMILE and may take 3 months or more for complete recovery.
Bufford, D; Liu, Y; Wang, J; Wang, H; Zhang, X
2014-09-10
Nanotwinned metals have been the focus of intense research recently, as twin boundaries may greatly enhance mechanical strength, while maintaining good ductility, electrical conductivity and thermal stability. Most prior studies have focused on low stacking-fault energy nanotwinned metals with coherent twin boundaries. In contrast, the plasticity of twinned high stacking-fault energy metals, such as aluminium with incoherent twin boundaries, has not been investigated. Here we report high work hardening capacity and plasticity in highly twinned aluminium containing abundant Σ3{112} incoherent twin boundaries based on in situ nanoindentation studies in a transmission electron microscope and corresponding molecular dynamics simulations. The simulations also reveal drastic differences in deformation mechanisms between nanotwinned copper and twinned aluminium ascribed to stacking-fault energy controlled dislocation-incoherent twin boundary interactions. This study provides new insight into incoherent twin boundary-dominated plasticity in high stacking-fault energy twinned metals.
Intuitive (in)coherence judgments are guided by processing fluency, mood and affect.
Sweklej, Joanna; Balas, Robert; Pochwatko, Grzegorz; Godlewska, Małgorzata
2014-01-01
Recently proposed accounts of intuitive judgments of semantic coherence assume that processing fluency results in a positive affective response leading to successful assessment of semantic coherence. The present paper investigates whether processing fluency may indicate semantic incoherence as well. In two studies, we employ a new paradigm in which participants have to detect an incoherent item among semantically coherent words. In Study 1, we show participants accurately indicating an incoherent item despite not being able to provide an accurate solution to coherent words. Further, this effect is modified by affective valence of solution words that are not retrieved from memory. Study 2 replicates those results and extend them by showing that mood moderates incoherence judgments independently of affective valence of solutions. The results support processing fluency account of intuitive semantic coherence judgments and show that it is not fluency per se but fluency variations that drive judgments.
2011-04-01
habits, and the complex nature of health care operations resulting from team efforts. Concerns about medical liability from medical malpractice ...investigations as blame is easier to assign to one individual than to evaluate the layers of an organization for failures. Medical malpractice fears...Risk Manager will brief the MTF/CC and Executive Staff on MTF medical malpractice claims semi-annually as well as discuss lessons learned, systemic
Coming Soon to an MTF Near You: Psychological Health Policy Initiatives
2011-01-25
Force Health Protection and Readiness Coming Soon to an MTF Near You: Psychological Health Policy Initiatives 25 Jan 11 LCDR Nicole Frazer, Ph.D. & Dr...it does not display a currently valid OMB control number. 1. REPORT DATE 25 JAN 2011 2. REPORT TYPE 3. DATES COVERED 00-00-2011 to 00-00-2011...if a disaster were to occur next week? *U.S. Navy photo by Mass Communication Specialist 1st Class Carmichael Yepez, 5/12/10, Armona, CA 2011 MHS
Incoherent vector mesons production in PbPb ultraperipheral collisions at the LHC
NASA Astrophysics Data System (ADS)
Xie, Ya-Ping; Chen, Xurong
2017-03-01
The incoherent rapidity distributions of vector mesons are computed in dipole model in PbPb ultraperipheral collisions at the CERN Large Hadron Collider (LHC). The IIM model fitted from newer data is employed in the dipole amplitude. The Boosted Gaussian and Gaus-LC wave functions for vector mesons are implemented in the calculations as well. Predictions for the J / ψ, ψ (2 s), ρ and ϕ incoherent rapidity distributions are evaluated and compared with experimental data and other theoretical predictions in this paper. We obtain closer predictions of the incoherent rapidity distributions for J / ψ than previous calculations in the IIM model.
Transform-limited-pulse representation of excitation with natural incoherent light
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chenu, Aurélia, E-mail: aurelia.chenu@utoronto.ca; Brumer, Paul, E-mail: pbrumer@chem.utoronto.ca
2016-01-28
The excitation of molecular systems by natural incoherent light relevant, for example, to photosynthetic light-harvesting is examined. We show that the result of linear excitation with natural incoherent light can be obtained using incident light described in terms of transform limited pulses, as opposed to conventional classical representations with explicit random character. The derived expressions allow for computations to be done directly for any thermal light spectrum using a simple wave function formalism and provide a route to the experimental determination of natural incoherent excitation using pulsed laser techniques. Pulses associated with solar and cosmic microwave background radiation are providedmore » as examples.« less
Leading twist nuclear shadowing phenomena in hard processes with nuclei
L. Franfurt; Guzey, V.; Strikman, M.
2012-01-08
We present and discuss the theory and phenomenology of the leading twist theory of nuclear shadowing which is based on the combination of the generalization of Gribov-Glauber theory, QCD factorization theorems, and HERA QCD analysis of diffraction in lepton-proton deep inelastic scattering (DIS). We apply this technique for the analysis of a wide range of hard processes with nuclei-inclusive DIS on deuterons, medium-range and heavy nuclei, coherent and incoherent diffractive DIS with nuclei, and hard diffraction in proton-nucleus scattering - and make predictions for the effect of nuclear shadowing in the corresponding sea quark and gluon parton distributions. We alsomore » analyze the role of the leading twist nuclear shadowing in generalized parton distributions in nuclei and certain characteristics of final states in nuclear DIS. We discuss the limits of applicability of the leading twist approximation for small x scattering off nuclei and the onset of the black disk regime and methods of detecting it. It will be possible to check many of our predictions in the near future in the studies of the ultraperipheral collisions at the Large Hadron Collider (LHC). Further checks will be possible in pA collisions at the LHC and forward hadron production at Relativistic Heavy Ion Collider (RHIC). As a result, detailed tests will be possible at an Electon-Ion Collider (EIC) in USA and at the Large Hadron-Electron Collider (LHeC) at CERN.« less
Characterization of on-site digital mammography systems: Direct versus indirect conversion detectors
NASA Astrophysics Data System (ADS)
Youn, Hanbean; Han, Jong Chul; Yun, Seungman; Kam, Soohwa; Cho, Seungryong; Kim, Ho Kyung
2015-06-01
We investigated the performances of two digital mammography systems. The systems use a cesium-iodide (CsI) scintillator and an amorphous selenium ( a-Se) photoconductor for X-ray detection and are installed in the same hospital. As physical metrics, we measured the modulationtransfer function (MTF), the noise-power spectrum (NPS), and the detective quantum efficiency (DQE). In addition, we analyzed the contrast-detail performances of the two systems by using a commercial contrast-detail phantom. The CsI-based indirect conversion detector provided better MTF and DQE performances than the a-Se-based direct conversion detector whereas the former provided a poorer NPS performance than the latter. These results are explained by the fact that the CsI-based detector used an MTF restoration preprocessing algorithm. The a-Se-based detector showed better contrast-detail performance than the CsI-based detector. We believe that the highfrequency noise characteristic of a detector is more responsible for the visibility of small details than its spatial-resolution performance.
Li, Jin; Liu, Zilong; Liu, Si
2017-02-20
In on-board photographing processes of satellite cameras, the platform vibration can generate image motion, distortion, and smear, which seriously affect the image quality and image positioning. In this paper, we create a mathematical model of a vibrating modulate transfer function (VMTF) for a remote-sensing camera. The total MTF of a camera is reduced by the VMTF, which means the image quality is degraded. In order to avoid the degeneration of the total MTF caused by vibrations, we use an Mn-20Cu-5Ni-2Fe (M2052) manganese copper alloy material to fabricate a vibration-isolation mechanism (VIM). The VIM can transform platform vibration energy into irreversible thermal energy with its internal twin crystals structure. Our experiment shows the M2052 manganese copper alloy material is good enough to suppress image motion below 125 Hz, which is the vibration frequency of satellite platforms. The camera optical system has a higher MTF after suppressing the vibration of the M2052 material than before.
Modulation Transfer Function of Infrared Focal Plane Arrays
NASA Technical Reports Server (NTRS)
Gunapala, S. D.; Rafol, S. B.; Ting, D. Z.; Soibel, A.; Hill, C. J.; Khoshakhlagh, A.; Liu, J. K.; Mumolo, J. M.; Hoglund, L.; Luong, E. M.
2015-01-01
Modulation transfer function (MTF) is the ability of an imaging system to faithfully image a given object. The MTF of an imaging system quantifies the ability of the system to resolve or transfer spatial frequencies. In this presentation we will discuss the detail MTF measurements of 1024x1024 pixels mid -wavelength and long- wavelength quantum well infrared photodetector, and 320x256 pixels long- wavelength InAs/GaSb superlattice infrared focal plane arrays (FPAs). Long wavelength Complementary Barrier Infrared Detector (CBIRD) based on InAs/GaSb superlattice material is hybridized to recently designed and fabricated 320x256 pixel format ROIC. The n-type CBIRD was characterized in terms of performance and thermal stability. The experimentally measured NE delta T of the 8.8 micron cutoff n-CBIRD FPA was 18.6 mK with 300 K background and f/2 cold stop at 78K FPA operating temperature. The horizontal and vertical MTFs of this pixel fully delineated CBIRD FPA at Nyquist frequency are 49% and 52%, respectively.
[Comparison of noise characteristics of direct and indirect conversion flat panel detectors].
Murai, Masami; Kishimoto, Kenji; Tanaka, Katsuhisa; Oota, Kenji; Ienaga, Akinori
2010-11-20
Flat-panel detector (FPD) digital radiography systems have direct and indirect conversion systems, and the 2 conversion systems provide different imaging performances. We measured some imaging performances [input-output characteristic, presampled modulation transfer function (presampled MTF), noise power spectrum (NPS)] of direct and indirect FPD systems. Moreover, some image samples of the NPSs were visually evaluated by the pair comparison method. As a result, the presampled MTF of the direct FPD system was substantially higher than that of the indirect FPD system. The NPS of the direct FPD system had a high value for all spatial frequencies. In contrast, the NPS of the indirect FPD system had a lower value as the frequency became higher. The results of visual evaluations showed the same tendency as that found for NPSs. We elucidated the cause of the difference in NPSs in a simulation study, and we determined that the cause of the difference in the noise components of the direct and indirect FPD systems was closely related to the presampled MTF.
Improvement of the edge method for on-orbit MTF measurement.
Viallefont-Robinet, Françoise; Léger, Dominique
2010-02-15
The edge method is a widely used way to assess the on-orbit Modulation Transfer Function (MTF). Since good quality is required for the edge, the higher the spatial resolution, the better the results are. In this case, an artificial target can be built and used to ensure a good edge quality. For moderate spatial resolutions, only natural targets are available. Hence the edge quality is unknown and generally rather poor. Improvements of the method have been researched in order to compensate for the poor quality of natural edges. This has been done through the use of symmetry and/or a transfer function model, which enables the elimination of noise. This has also been used for artificial target. In this case, the use of the model overcomes the incomplete sampling when the target is too small or gives the opportunity to assess the defocus of the sensor. This paper begins with a recall of the method followed by a presentation of the changes relying on transfer function parametric model. The transfer function model and the process corresponding to the changes are described. Applications of these changes for several satellites of the French spatial agency are presented: for SPOT 1, it enables to assess XS MTF with natural edges, for SPOT 5, it enables to use the Salon-de-Provence artificial target for MTF assessment in the HM mode, and for the foreseen Pleiades, it enables to estimate the defocus.
Characterizing 3D sensors using the 3D modulation transfer function
NASA Astrophysics Data System (ADS)
Kellner, Timo; Breitbarth, Andreas; Zhang, Chen; Notni, Gunther
2018-03-01
The fields of optical 3D measurement system applications are continuously expanding and becoming more and more diverse. To evaluate appropriate systems for various measurement tasks, comparable parameters are necessary, whereas the 3D modulation transfer function (3D-MTF) has been established as a further criterion. Its aim is the determination of the system response between the measurement of a straight, sharp-edged cube and its opposite ideal calculated one. Within the scope of this work simulations and practical investigations regarding the 3D-MTF’s influences and its main issues are specifically investigated. Therefore, different determined edge radii representing the high-frequency spectra lead to various decreasing 3D-MTF characteristics. Furthermore, rising sampling frequencies improve its maximum transfer value to a saturation point in dependence of the radius. To approve these results of previous simulations, three fringe projection scanners were selected to determine the diversity. As the best 3D-MTF characteristic, a saturated transfer value of H_3D( f_N, 3D) = 0.79 has been identified at a sufficient sampling frequency, which is reached at four times the Nyquist limit. This high 3D resolution can mainly be achieved due to an improved camera projector interaction. Additionally, too small sampling ratios lead to uncertainties in the edge function determination, while higher ratios do not show major improvements. In conclusion, the 3D-MTF algorithm has thus been practically verified and its repeatability as well as its robustness have been confirmed.
Gizewski, Elke R; Krause, Eva; Schlamann, Marc; Happich, Friederike; Ladd, Mark E; Forsting, Michael; Senf, Wolfgang
2009-02-01
Transsexuals harbor the strong feeling of having been born to the wrong sex. There is a continuing controversial discussion of whether or not transsexualism has a biological representation. Differences between males and females in terms of functional imaging during erotic stimuli have been previously described, revealing gender-specific results. Therefore, we postulated that male-to-female (MTF) transsexuals may show specific cerebral activation differing from their biological gender. Cerebral activation patterns during viewing of erotic film excerpts in functional magnetic resonance imaging (fMRI). Twelve male and 12 female heterosexual volunteers and 12 MTF transsexuals before any treatment viewed erotic film excerpts during fMRI. Additionally, subjective rating of sexual arousal was assessed. Statistics were performed using the Statistical Parametric Mapping software. Significantly enhanced activation for men compared with women was revealed in brain areas involved in erotic processing, i.e., the thalamus, the amygdala, and the orbitofrontal and insular cortex, whereas no specific activation for women was found. When comparing MTF transsexuals with male volunteers, activation patterns similar to female volunteers being compared with male volunteers were revealed. Sexual arousal was assessed using standard rating scales and did not differ significantly for the three groups. We revealed a cerebral activation pattern in MTF transsexuals compared with male controls similar to female controls compared with male controls during viewing of erotic stimuli, indicating a tendency of female-like cerebral processing in transsexualism.
Geographic variation within the military health system.
Kimsey, Linda; Olaiya, Samuel; Smith, Chad; Hoburg, Andrew; Lipsitz, Stuart R; Koehlmoos, Tracey; Nguyen, Louis L; Weissman, Joel S
2017-04-13
This study seeks to quantify variation in healthcare utilization and per capita costs using system-defined geographic regions based on enrollee residence within the Military Health System (MHS). Data for fiscal years 2007 - 2010 were obtained from the Military Health System under a data sharing agreement with the Defense Health Agency (DHA). DHA manages all aspects of the Department of Defense Military Health System, including TRICARE. Adjusted rates were calculated for per capita costs and for two procedures with high interest to the MHS- back surgery and Cesarean sections for TRICARE Prime and Plus enrollees. Coefficients of variation (CoV) and interquartile ranges (IQR) were calculated and analyzed using residence catchment area as the geographic unit. Catchment areas anchored by a Military Treatment Facility (MTF) were compared to catchment areas not anchored by a MTF. Variation, as measured by CoV, was 0.37 for back surgery and 0.13 for C-sections in FY 2010- comparable to rates documented in other healthcare systems. The 2010 CoV (and average cost) for per capita costs was 0.26 ($3,479.51). Procedure rates were generally lower and CoVs higher in regions anchored by a MTF compared with regions not anchored by a MTF, based on both system-wide comparisons and comparisons of neighboring areas. In spite of its centrally managed system and relatively healthy beneficiaries with very robust health benefits, the MHS is not immune to unexplained variation in utilization and cost of healthcare.
Kuttig, Jan D; Steiding, Christian; Kolditz, Daniel; Hupfer, Martin; Karolczak, Marek; Kalender, Willi A
2015-06-01
To investigate the dose saving potential of direct-converting CdTe photon-counting detector technology for dedicated breast CT. We analyzed the modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) of two detector technologies, suitable for breast CT (BCT): a flat-panel energy-integrating detector with a 70 μm and a 208 μm thick gadolinium oxysulfide (GOS) and a 150 μm thick cesium iodide (CsI) scintillator and a photon-counting detector with a 1000 μm thick CdTe sensor. The measurements for GOS scintillator thicknesses of 70 μm and 208 μm delivered 10% pre-sampled MTF values of 6.6 mm(-1) and 3.2 mm(-1), and DQE(0) values of 23% and 61%. The 10% pre-sampled MTF value for the 150 μm thick CsI scintillator 6.9 mm(-1), and the DQE(0) value was 49%. The CdTe sensor reached a 10% pre-sampled MTF value of 8.5 mm(-1) and a DQE(0) value of 85%. The photon-counting CdTe detector technology allows for significant dose reduction compared to the energy-integrating scintillation detector technology used in BCT today. Our comparative evaluation indicates that a high potential dose saving may be possible for BCT by using CdTe detectors, without loss of spatial resolution. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Linear chirped slope profile for spatial calibration in slope measuring deflectometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siewert, F., E-mail: frank.siewert@helmholtz-berlin.de; Zeschke, T.; Arnold, T.
2016-05-15
Slope measuring deflectometry is commonly used by the X-ray optics community to measure the long-spatial-wavelength surface figure error of optical components dedicated to guide and focus X-rays under grazing incidence condition at synchrotron and free electron laser beamlines. The best performing instruments of this kind are capable of absolute accuracy on the level of 30-50 nrad. However, the exact bandwidth of the measurements, determined at the higher spatial frequencies by the instrument’s spatial resolution, or more generally by the instrument’s modulation transfer function (MTF) is hard to determine. An MTF calibration method based on application of a test surface withmore » a one-dimensional (1D) chirped height profile of constant amplitude was suggested in the past. In this work, we propose a new approach to designing the test surfaces with a 2D-chirped topography, specially optimized for MTF characterization of slope measuring instruments. The design of the developed MTF test samples based on the proposed linear chirped slope profiles (LCSPs) is free of the major drawback of the 1D chirped height profiles, where in the slope domain, the amplitude strongly increases with the local spatial frequency of the profile. We provide the details of fabrication of the LCSP samples. The results of first application of the developed test samples to measure the spatial resolution of the BESSY-NOM at different experimental arrangements are also presented and discussed.« less
Hi-Res scan mode in clinical MDCT systems: Experimental assessment of spatial resolution performance
Cruz-Bastida, Juan P.; Gomez-Cardona, Daniel; Li, Ke; Sun, Heyi; Hsieh, Jiang; Szczykutowicz, Timothy P.; Chen, Guang-Hong
2016-01-01
Purpose: The introduction of a High-Resolution (Hi-Res) scan mode and another associated option that combines Hi-Res mode with the so-called High Definition (HD) reconstruction kernels (referred to as a Hi-Res/HD mode in this paper) in some multi-detector CT (MDCT) systems offers new opportunities to increase spatial resolution for some clinical applications that demand high spatial resolution. The purpose of this work was to quantify the in-plane spatial resolution along both the radial direction and tangential direction for the Hi-Res and Hi-Res/HD scan modes at different off-center positions. Methods: A technique was introduced and validated to address the signal saturation problem encountered in the attempt to quantify spatial resolution for the Hi-Res and Hi-Res/HD scan modes. Using the proposed method, the modulation transfer functions (MTFs) of a 64-slice MDCT system (Discovery CT750 HD, GE Healthcare) equipped with both Hi-Res and Hi-Res/HD modes were measured using a metal bead at nine different off-centered positions (0–16 cm with a step size of 2 cm); at each position, both conventional scans and Hi-Res scans were performed. For each type of scan and position, 80 repeated acquisitions were performed to reduce noise induced uncertainties in the MTF measurements. A total of 15 reconstruction kernels, including eight conventional kernels and seven HD kernels, were used to reconstruct CT images of the bead. An ex vivo animal study consisting of a bone fracture model was performed to corroborate the MTF results, as the detection of this high-contrast and high frequency task is predominantly determined by spatial resolution. Images of this animal model generated by different scan modes and reconstruction kernels were qualitatively compared with the MTF results. Results: At the centered position, the use of Hi-Res mode resulted in a slight improvement in the MTF; each HD kernel generated higher spatial resolution than its counterpart conventional kernel. However, the MTF along the tangential direction of the scan field of view (SFOV) was significantly degraded at off-centered positions, yet the combined Hi-Res/HD mode reduced this azimuthal MTF degradation. Images of the animal bone fracture model confirmed the improved spatial resolution at the off-centered positions through the use of the Hi-Res mode and HD kernels. Conclusions: The Hi-Res/HD scan improve spatial resolution of MDCT systems at both centered and off-centered positions. PMID:27147351
Cruz-Bastida, Juan P; Gomez-Cardona, Daniel; Li, Ke; Sun, Heyi; Hsieh, Jiang; Szczykutowicz, Timothy P; Chen, Guang-Hong
2016-05-01
The introduction of a High-Resolution (Hi-Res) scan mode and another associated option that combines Hi-Res mode with the so-called High Definition (HD) reconstruction kernels (referred to as a Hi-Res/HD mode in this paper) in some multi-detector CT (MDCT) systems offers new opportunities to increase spatial resolution for some clinical applications that demand high spatial resolution. The purpose of this work was to quantify the in-plane spatial resolution along both the radial direction and tangential direction for the Hi-Res and Hi-Res/HD scan modes at different off-center positions. A technique was introduced and validated to address the signal saturation problem encountered in the attempt to quantify spatial resolution for the Hi-Res and Hi-Res/HD scan modes. Using the proposed method, the modulation transfer functions (MTFs) of a 64-slice MDCT system (Discovery CT750 HD, GE Healthcare) equipped with both Hi-Res and Hi-Res/HD modes were measured using a metal bead at nine different off-centered positions (0-16 cm with a step size of 2 cm); at each position, both conventional scans and Hi-Res scans were performed. For each type of scan and position, 80 repeated acquisitions were performed to reduce noise induced uncertainties in the MTF measurements. A total of 15 reconstruction kernels, including eight conventional kernels and seven HD kernels, were used to reconstruct CT images of the bead. An ex vivo animal study consisting of a bone fracture model was performed to corroborate the MTF results, as the detection of this high-contrast and high frequency task is predominantly determined by spatial resolution. Images of this animal model generated by different scan modes and reconstruction kernels were qualitatively compared with the MTF results. At the centered position, the use of Hi-Res mode resulted in a slight improvement in the MTF; each HD kernel generated higher spatial resolution than its counterpart conventional kernel. However, the MTF along the tangential direction of the scan field of view (SFOV) was significantly degraded at off-centered positions, yet the combined Hi-Res/HD mode reduced this azimuthal MTF degradation. Images of the animal bone fracture model confirmed the improved spatial resolution at the off-centered positions through the use of the Hi-Res mode and HD kernels. The Hi-Res/HD scan improve spatial resolution of MDCT systems at both centered and off-centered positions.
Secure uniform random-number extraction via incoherent strategies
NASA Astrophysics Data System (ADS)
Hayashi, Masahito; Zhu, Huangjun
2018-01-01
To guarantee the security of uniform random numbers generated by a quantum random-number generator, we study secure extraction of uniform random numbers when the environment of a given quantum state is controlled by the third party, the eavesdropper. Here we restrict our operations to incoherent strategies that are composed of the measurement on the computational basis and incoherent operations (or incoherence-preserving operations). We show that the maximum secure extraction rate is equal to the relative entropy of coherence. By contrast, the coherence of formation gives the extraction rate when a certain constraint is imposed on the eavesdropper's operations. The condition under which the two extraction rates coincide is then determined. Furthermore, we find that the exponential decreasing rate of the leaked information is characterized by Rényi relative entropies of coherence. These results clarify the power of incoherent strategies in random-number generation, and can be applied to guarantee the quality of random numbers generated by a quantum random-number generator.
Joint transform correlators with spatially incoherent illumination
NASA Astrophysics Data System (ADS)
Bykovsky, Yuri A.; Karpiouk, Andrey B.; Markilov, Anatoly A.; Rodin, Vladislav G.; Starikov, Sergey N.
1997-03-01
Two variants of joint transform correlators with monochromatic spatially incoherent illumination are considered. The Fourier-holograms of the reference and recognized images are recorded simultaneously or apart in a time on the same spatial light modulator directly by monochromatic spatially incoherent light. To create the signal of mutual correlation of the images it is necessary to execute nonlinear transformation when the hologram is illuminated by coherent light. In the first scheme of the correlator this aim was achieved by using double pas of a restoring coherent wave through the hologram. In the second variant of the correlator the non-linearity of the characteristic of the spatial light modulator for hologram recording was used. Experimental schemes and results on processing teste images by both variants of joint transform correlators with monochromatic spatially incoherent illumination. The use of spatially incoherent light on the input of joint transform correlators permits to reduce the requirements to optical quality of elements, to reduce accuracy requirements on elements positioning and to expand a number of devices suitable to input images in correlators.
Comparative Characteristics Of Coherent And Incoherent Radiation In The Photography Of Ulcer
NASA Astrophysics Data System (ADS)
Novikov, V. F.; Paramonov, L. V.
1985-01-01
The efficiency of He-Ne laser radiation and incoherent radiation by red light sources with different spectral bandwidths is compared for the endoscopic phototherapy of gastric and duodenal ulcers. Coherent and incoherent radiation is determined to result in the same theraputic effect when doing the treatment of ulcer deseases. The methods of ulcer treatment is suggested with a conventional fibrogastroscope fitted with red glass filter.
NASA Astrophysics Data System (ADS)
Dingreville, Rémi; Hallil, Abdelmalek; Berbenni, Stéphane
2014-12-01
The equilibrium of coherent and incoherent mismatched interfaces is reformulated in the context of continuum mechanics based on the Gibbs dividing surface concept. Two surface stresses are introduced: a coherent surface stress and an incoherent surface stress, as well as a transverse excess strain. The coherent surface stress and the transverse excess strain represent the thermodynamic driving forces of stretching the interface while the incoherent surface stress represents the driving force of stretching one crystal while holding the other fixed and thereby altering the structure of the interface. These three quantities fully characterize the elastic behavior of coherent and incoherent interfaces as a function of the in-plane strain, the transverse stress and the mismatch strain. The isotropic case is developed in detail and particular attention is paid to the case of interfacial thermo-elasticity. This exercise provides an insight on the physical significance of the interfacial elastic constants introduced in the formulation and illustrates the obvious coupling between the interface structure and its associated thermodynamics quantities. Finally, an example based on atomistic simulations of Cu/Cu2O interfaces is given to demonstrate the relevance of the generalized interfacial formulation and to emphasize the dependence of the interfacial thermodynamic quantities on the incoherency strain with an actual material system.
Dingreville, Rémi; Hallil, Abdelmalek; Berbenni, Stéphane
2014-08-19
The equilibrium of coherent and incoherent mismatched interfaces is reformulated in the context of continuum mechanics based on the Gibbs dividing surface concept. Two surface stresses are introduced: a coherent surface stress and an incoherent surface stress, as well as a transverse excess strain. Additionally, the coherent surface stress and the transverse excess strain represent the thermodynamic driving forces of stretching the interface while the incoherent surface stress represents the driving force of stretching one crystal while holding the other fixed and thereby altering the structure of the interface. These three quantities fully characterize the elastic behavior of coherent andmore » incoherent interfaces as a function of the in-plane strain, the transverse stress and the mismatch strain. The isotropic case is developed in detail and particular attention is paid to the case of interfacial thermo-elasticity. This exercise provides an insight on the physical significance of the interfacial elastic constants introduced in the formulation and illustrates the obvious coupling between the interface structure and its associated thermodynamics quantities. Finally, an example based on atomistic simulations of Cu/Cu 2O interfaces is given to demonstrate the relevance of the generalized interfacial formulation and to emphasize the dependence of the interfacial thermodynamic quantities on the incoherency strain with an actual material system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nihill, Kevin J.; Hund, Zachary M.; Sibener, S. J., E-mail: s-sibener@uchicago.edu
2016-08-28
Fundamental details concerning the interaction between H{sub 2} and CH{sub 3}–Si(111) have been elucidated by the combination of diffractive scattering experiments and electronic structure and scattering calculations. Rotationally inelastic diffraction (RID) of H{sub 2} and D{sub 2} from this model hydrocarbon-decorated semiconductor interface has been confirmed for the first time via both time-of-flight and diffraction measurements, with modest j = 0 → 2 RID intensities for H{sub 2} compared to the strong RID features observed for D{sub 2} over a large range of kinematic scattering conditions along two high-symmetry azimuthal directions. The Debye-Waller model was applied to the thermal attenuationmore » of diffraction peaks, allowing for precise determination of the RID probabilities by accounting for incoherent motion of the CH{sub 3}–Si(111) surface atoms. The probabilities of rotationally inelastic diffraction of H{sub 2} and D{sub 2} have been quantitatively evaluated as a function of beam energy and scattering angle, and have been compared with complementary electronic structure and scattering calculations to provide insight into the interaction potential between H{sub 2} (D{sub 2}) and hence the surface charge density distribution. Specifically, a six-dimensional potential energy surface (PES), describing the electronic structure of the H{sub 2}(D{sub 2})/CH{sub 3}−Si(111) system, has been computed based on interpolation of density functional theory energies. Quantum and classical dynamics simulations have allowed for an assessment of the accuracy of the PES, and subsequently for identification of the features of the PES that serve as classical turning points. A close scrutiny of the PES reveals the highly anisotropic character of the interaction potential at these turning points. This combination of experiment and theory provides new and important details about the interaction of H{sub 2} with a hybrid organic-semiconductor interface, which can be used to further investigate energy flow in technologically relevant systems.« less
Xiao, Z; Tang, Z; Qiang, J; Wang, S; Qian, W; Zhong, Y; Wang, R; Wang, J; Wu, L; Tang, W; Zhang, Z
2018-01-25
Intravoxel incoherent motion is a promising method for the differentiation of sinonasal lesions. This study aimed to evaluate the value of intravoxel incoherent motion in the differentiation of benign and malignant sinonasal lesions and to compare the diagnostic performance of intravoxel incoherent motion with that of conventional DWI. One hundred thirty-one patients with histologically proved solid sinonasal lesions (56 benign and 75 malignant) who underwent conventional DWI and intravoxel incoherent motion were recruited in this study. The diffusion coefficient ( D ), pseudodiffusion coefficient ( D *), and perfusion fraction ( f ) values derived from intravoxel incoherent motion and ADC values derived from conventional DWI were measured and compared between the 2 groups using the Student t test. Receiver operating characteristic curve analysis, logistic regression analysis, and 10-fold cross-validation were performed to evaluate the diagnostic performance of single-parametric and multiparametric models. The mean ADC and D values were significantly lower in malignant sinonasal lesions than in benign sinonasal lesions (both P < .001). The mean f value was higher in malignant lesions than in benign lesions ( P = .003). Multiparametric models can significantly improve the cross-validated areas under the curve for the differentiation of sinonasal lesions compared with single-parametric models (all corrected P < .05 except the D value). The model of D + f provided a better diagnostic performance than the ADC value (corrected P < .001). Intravoxel incoherent motion appears to be a more effective MR imaging technique than conventional DWI in the differentiation of benign and malignant sinonasal lesions. © 2018 by American Journal of Neuroradiology.
NASA Astrophysics Data System (ADS)
Xu, Tao; Liao, Jingjuan
2014-11-01
In order to reveal more deeply the scattering characteristics of wetland vegetation and determine the microwave scattering model suitable for the inversion of wetland vegetation parameters, the comparison and analysis between microwave coherent and incoherent scattering models for wetland vegetation in Poyang Lake area were performed in this paper. In the research, we proposed a coherent scattering model exclusive for wetland vegetation, in which, Generalized Rayleigh-Gans (GRG) approach and infinite-length dielectric cylinder were used to calculate single-scattering matrices of wetland vegetation leaves and stalks. In addition, coherent components produced from interaction among the scattering mechanisms and different scatterers were also considered and this coherent model was compared with Michigan Microwave Canopy Scattering (MIMICS) model. The measured data collected in 2011 in Poyang Lake wetland were used as the input parameters of the coherent and incoherent models. We simulated backscattering coefficients of VV, VH and HH polarization at C band and made a comparison between the simulation results and C-band data from the Radarsat-2 satellite. For both coherent and incoherent scattering model, simulation results for HH and VV polarization were better than the simulation results for HV polarization. In addition, comparisons between coherent and incoherent scattering models proved that the coherence triggered by the scattering mechanism and different scatterers can't be ignored. In the research, we analyzed differences between coherent and incoherent scattering models with change of incident angle. In most instances, the difference between coherent and incoherent scattering models is of the order of several dB.
NASA Astrophysics Data System (ADS)
Guasoni, M.; Garnier, J.; Rumpf, B.; Sugny, D.; Fatome, J.; Amrani, F.; Millot, G.; Picozzi, A.
2017-01-01
The long-standing and controversial Fermi-Pasta-Ulam problem addresses fundamental issues of statistical physics, and the attempt to resolve the mystery of the recurrences has led to many great discoveries, such as chaos, integrable systems, and soliton theory. From a general perspective, the recurrence is commonly considered as a coherent phase-sensitive effect that originates in the property of integrability of the system. In contrast to this interpretation, we show that convection among a pair of waves is responsible for a new recurrence phenomenon that takes place for strongly incoherent waves far from integrability. We explain the incoherent recurrence by developing a nonequilibrium spatiotemporal kinetic formulation that accounts for the existence of phase correlations among incoherent waves. The theory reveals that the recurrence originates in a novel form of modulational instability, which shows that strongly correlated fluctuations are spontaneously created among the random waves. Contrary to conventional incoherent modulational instabilities, we find that Landau damping can be completely suppressed, which unexpectedly removes the threshold of the instability. Consequently, the recurrence can take place for strongly incoherent waves and is thus characterized by a reduction of nonequilibrium entropy that violates the H theorem of entropy growth. In its long-term evolution, the system enters a secondary turbulent regime characterized by an irreversible process of relaxation to equilibrium. At variance with the expected thermalization described by standard Gibbsian statistical mechanics, our thermalization process is not dictated by the usual constraints of energy and momentum conservation: The inverse temperatures associated with energy and momentum are zero. This unveils a previously unrecognized scenario of unconstrained thermalization, which is relevant to a variety of weakly dispersive wave systems. Our work should stimulate the development of new experiments aimed at observing recurrence behaviors with random waves. From a broader perspective, the spatiotemporal kinetic formulation we develop here paves the way to the study of novel forms of global incoherent collective behaviors in wave turbulence, such as the formation of incoherent breather structures.
Emulation Aid System II (EASY II) System Programmer’s Guide.
1981-03-01
DISK-SAVE, PASSWD =SSSS .MTUINIT= 17 ,MTF IILE=99,D)SKUNIT=7. RESTORE-DISK, PASSWD =SSSS,,MTt!NI=I 7,MTF [LE--=99,DSKtJNIT=7. where PASSWD - a system disk...DISK-SAVE, PASSWD =SSSS ,MTUNIT=17,MTFILE=99,DSKtJNIT=7. SAVE A DISK FILE ON TAPE HELP ,O,O,O. DSKSV. EDIT. CR’r BASED EDITOR (COMM ANDS EXPLAINED AS...BE EXPLICITLY TURNED ON QCNTRL ,LOCKED. RDTAPE,UNIT= 17. READING TAPE FOR USE WITH 6000 AND PRINT. 0. RDTAPE. RESTORE-DISK, PASSWD =SSSS ,MTUNIT= 17
1991-07-01
MTF, or establishing a standard CGR should be done cautiously since health care is a local phenomenon and a number of factors influence (1) the...goals should be formulated locally. That is, each MTF must identify for itself those beneficiaries in its catchment area with billable insurance who...this, managers must know the work they supervise. 8. Drive out fear. Employees should not be afraid to point out problems for fear of argument or being
Bolea, Mario; Mora, José; Ortega, Beatriz; Capmany, José
2012-03-12
A novel all-optical technique based on the incoherent processing of optical signals using high-order dispersive elements is analyzed for microwave arbitrary pulse generation. We show an approach which allows a full reconfigurability of a pulse in terms of chirp, envelope and central frequency by the proper control of the second-order dispersion and the incoherent optical source power distribution, achieving large values of time-bandwidth product.
Coherent vs Incoherent Emission from Semiconductor Structures after Resonant Femtosecond Excitation
NASA Astrophysics Data System (ADS)
Gurioli, Massimo; Bogani, Franco; Ceccherini, Simone; Colocci, Marcello
1997-04-01
We show that an interferometric correlation measurement with fs time resolution provides an unambiguous discrimination between coherent and incoherent emission after resonant femtosecond excitation. The experiment directly probes the most important difference between the two emissions, that is, the phase correlation with the excitation pulse. The comparison with cw frequency resolved measurements demonstrates that the relationship between coherent and incoherent emission is similar under femtosecond and steady-state excitation.
NASA Astrophysics Data System (ADS)
Martin-Lopez, S.; Carrasco-Sanz, A.; Corredera, P.; Abrardi, L.; Hernanz, M. L.; Gonzalez-Herraez, M.
2006-12-01
The development of high-power cw fiber lasers has triggered a great interest in the phenomena of nonlinear pump spectral broadening and cw supercontinuum generation. These effects have very convenient applications in Raman amplification, optical fiber metrology, and fiber sensing. In particular, it was recently shown that pump incoherence has a strong impact in these processes. We study experimentally the effect of pump incoherence in nonlinear pump spectral broadening and cw supercontinuum generation in optical fibers. We show that under certain experimental conditions an optimum degree of pump incoherence yields the best performance in the broadening process. We qualitatively explain these results, and we point out that these results may have important implications in cw supercontinuum optimization.
Abdul Aziz,, Siti Aishah; Mohd Saparudin, Abdul Khaliq; Harun, Ahmad Zaky
2013-01-01
Background: Different target-filter combinations in computed radiography have different impacts on the dose and image quality in digital radiography. This study aims to evaluate the mean glandular dose (MGD) and modulation transfer function (MTF) of various target-filter combinations by investigating the signal intensities of X-ray beams. Methods: General Electric (GE) Senographe DMR Plus mammography unit was used for MGD and MTF evaluation. The measured MGD was compared with the dose reference level (DRL), whereas the MTF was evaluated using ImageJ 1.46o software. A modified Mammography Accreditation Phantom RMI 156 was exposed using different target-filter combinations of molybdenum-molybdenum (Mo-Mo), molybdenum-rhodium (Mo-Rh) and rhodium-rhodium (Rh-Rh) at two different tube voltages, 26 kV and 32 kV with 50 mAs. Results: In the MGD evaluations, all target-filters gave an MGD value of < 1.5 mGy. The one-way ANOVA test showed a highly significant interaction between the MGD and the kilovoltage and target-filter material used (26 kV: F (2,12) = 49,234, P = 0.001;32 kV: F (2,12) = 89,972, P = 0.001). A Tukey post-hoc test revealed that the MGD for 26 kV and 32 kV was highly affected by the target-filter combinations. The test of homogeneity of variances indicates that the MGD varies significantly for 26 kV and 32 kV images (0.045 and 0.030 (P < 0.05), respectively). However, the one-way ANOVA for the MTF shows that no significant difference exists between the target-filter combinations used with 26 kV and 32 kV images either in parallel or perpendicular to the chest wall side F (2,189) = 0.26, P > 0.05). Conclusion: Higher tube voltage and atomic number target-filter yield higher MGD values. However, the MTF is independent of the X-ray energy and the type of target-filter combinations used. PMID:23966821
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gislason-Lee, Amber J., E-mail: A.J.Gislason@leeds.ac.uk; Tunstall, Clare M.; Kengyelics, Stephen K.
Purpose: Cardiac x-ray detectors are used to acquire moving images in real-time for angiography and interventional procedures. Detective quantum efficiency (DQE) is not generally measured on these dynamic detectors; the required “for processing” image data and control of x-ray settings have not been accessible. By 2016, USA hospital physicists will have the ability to measure DQE and will likely utilize the International Electrotechnical Commission (IEC) standard for measuring DQE of dynamic x-ray imaging devices. The current IEC standard requires an image of a tilted tungsten edge test object to obtain modulation transfer function (MTF) for DQE calculation. It specifies themore » range of edge angles to use; however, it does not specify a preferred method to determine this angle for image analysis. The study aimed to answer the question “will my choice in method impact my results?” Four different established edge angle determination methods were compared to investigate the impact on DQE. Methods: Following the IEC standard, edge and flat field images were acquired on a cardiac flat-panel detector to calculate MTF and noise power spectrum, respectively, to determine DQE. Accuracy of the methods in determining the correct angle was ascertained using a simulated edge image with known angulations. Precision of the methods was ascertained using variability of MTF and DQE, calculated via bootstrapping. Results: Three methods provided near equal angles and the same MTF while the fourth, with an angular difference of 6%, had a MTF lower by 3% at 1.5 mm{sup −1} spatial frequency and 8% at 2.5 mm{sup −1}; corresponding DQE differences were 6% at 1.5 mm{sup −1} and 17% at 2.5 mm{sup −1}; differences were greater than standard deviations in the measurements. Conclusions: DQE measurements may vary by a significant amount, depending on the method used to determine the edge angle when following the IEC standard methodology for a cardiac x-ray detector. The most accurate and precise methods are recommended for absolute assessments and reproducible measurements, respectively.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohkubo, Masaki, E-mail: mook@clg.niigata-u.ac.jp
Purpose: In lung cancer computed tomography (CT) screening, the performance of a computer-aided detection (CAD) system depends on the selection of the image reconstruction kernel. To reduce this dependence on reconstruction kernels, the authors propose a novel application of an image filtering method previously proposed by their group. Methods: The proposed filtering process uses the ratio of modulation transfer functions (MTFs) of two reconstruction kernels as a filtering function in the spatial-frequency domain. This method is referred to as MTF{sub ratio} filtering. Test image data were obtained from CT screening scans of 67 subjects who each had one nodule. Imagesmore » were reconstructed using two kernels: f{sub STD} (for standard lung imaging) and f{sub SHARP} (for sharp edge-enhancement lung imaging). The MTF{sub ratio} filtering was implemented using the MTFs measured for those kernels and was applied to the reconstructed f{sub SHARP} images to obtain images that were similar to the f{sub STD} images. A mean filter and a median filter were applied (separately) for comparison. All reconstructed and filtered images were processed using their prototype CAD system. Results: The MTF{sub ratio} filtered images showed excellent agreement with the f{sub STD} images. The standard deviation for the difference between these images was very small, ∼6.0 Hounsfield units (HU). However, the mean and median filtered images showed larger differences of ∼48.1 and ∼57.9 HU from the f{sub STD} images, respectively. The free-response receiver operating characteristic (FROC) curve for the f{sub SHARP} images indicated poorer performance compared with the FROC curve for the f{sub STD} images. The FROC curve for the MTF{sub ratio} filtered images was equivalent to the curve for the f{sub STD} images. However, this similarity was not achieved by using the mean filter or median filter. Conclusions: The accuracy of MTF{sub ratio} image filtering was verified and the method was demonstrated to be effective for reducing the kernel dependence of CAD performance.« less
Gender identity rather than sexual orientation impacts on facial preferences.
Ciocca, Giacomo; Limoncin, Erika; Cellerino, Alessandro; Fisher, Alessandra D; Gravina, Giovanni Luca; Carosa, Eleonora; Mollaioli, Daniele; Valenzano, Dario R; Mennucci, Andrea; Bandini, Elisa; Di Stasi, Savino M; Maggi, Mario; Lenzi, Andrea; Jannini, Emmanuele A
2014-10-01
Differences in facial preferences between heterosexual men and women are well documented. It is still a matter of debate, however, how variations in sexual identity/sexual orientation may modify the facial preferences. This study aims to investigate the facial preferences of male-to-female (MtF) individuals with gender dysphoria (GD) and the influence of short-term/long-term relationships on facial preference, in comparison with healthy subjects. Eighteen untreated MtF subjects, 30 heterosexual males, 64 heterosexual females, and 42 homosexual males from university students/staff, at gay events, and in Gender Clinics were shown a composite male or female face. The sexual dimorphism of these pictures was stressed or reduced in a continuous fashion through an open-source morphing program with a sequence of 21 pictures of the same face warped from a feminized to a masculinized shape. An open-source morphing program (gtkmorph) based on the X-Morph algorithm. MtF GD subjects and heterosexual females showed the same pattern of preferences: a clear preference for less dimorphic (more feminized) faces for both short- and long-term relationships. Conversely, both heterosexual and homosexual men selected significantly much more dimorphic faces, showing a preference for hyperfeminized and hypermasculinized faces, respectively. These data show that the facial preferences of MtF GD individuals mirror those of the sex congruent with their gender identity. Conversely, heterosexual males trace the facial preferences of homosexual men, indicating that changes in sexual orientation do not substantially affect preference for the most attractive faces. © 2014 International Society for Sexual Medicine.
Tandogan, Tamer; Auffarth, Gerd U; Choi, Chul Y; Liebing, Stephanie; Mayer, Christian; Khoramnia, Ramin
2017-02-08
To analyse objective optical properties of the spherical and aspheric design of the same intraocular lens (IOL) model using optical bench analysis. This study entailed a comparative analysis of 10 spherical C-flex 570 C and 10 aspheric C-flex 970 C IOLs (Rayner Intraocular Lenses Ltd., Hove, UK) of 26 diopters [D] using an optical bench (OptiSpheric, Trioptics, Germany). In all lenses, we evaluated the modulation transfer function (MTF) at 50 lp/mm and 100 lp/mm and the Strehl Ratio using a 3-mm (photopic) and 4.5-mm (mesopic) aperture. At 50 lp/mm, the MTF values were 0.713/0.805 (C-flex 570 C/C-flex 970 C) for a 3-mm aperture and 0.294/0.591 for a 4.5-mm aperture. At 100 lp/mm, the MTF values were 0.524/0.634 for a 3-mm aperture and 0.198/0.344 for a 4.5-mm aperture. The Strehl Ratio was 0.806/0.925 and 0.237/0.479 for a 3-mm and 4.5-mm aperture respectively. A Mann-Whitney U test revealed all intergroup differences to be statistically significant (p < 0.01). The aspheric IOL design achieved higher MTF values than the spherical design of the same IOL for both apertures. Moreover, the differences between the two designs of the IOL were more prominent for larger apertures. This suggests that the evaluated IOL provides enhanced optical quality to patients with larger pupils or working under mesopic conditions.
Clinical and theoretical parallels between desire for limb amputation and gender identity disorder.
Lawrence, Anne A
2006-06-01
Desire for amputation of a healthy limb has usually been regarded as a paraphilia (apotemnophilia), but some researchers propose that it may be a disorder of identity, similar to Gender Identity Disorder (GID) or transsexualism. Similarities between the desire for limb amputation and nonhomosexual male-to-female (MtF) transsexualism include profound dissatisfaction with embodiment, related paraphilias from which the conditions plausibly derive (apotemnophilia and autogynephilia), sexual arousal from simulation of the sought-after status (pretending to be an amputee and transvestism), attraction to persons with the same body type one wants to acquire, and an elevated prevalence of other paraphilic interests. K. Freund and R. Blanchard (1993) proposed that nonhomosexual MtF transsexualism represents an erotic target location error, in which men whose preferred erotic targets are women also eroticize their own feminized bodies. Desire for limb amputation may also reflect an erotic target location error, occurring in combination with an unusual erotic target preference for amputees. This model predicts that persons who desire limb amputation would almost always be attracted to amputees and would display an increased prevalence of gender identity problems, both of which have been observed. Persons who desire limb amputation and nonhomosexual MtF transsexuals often assert that their motives for wanting to change their bodies reflect issues of identity rather than sexuality, but because erotic/romantic orientations contribute significantly to identity, such distinctions may not be meaningful. Experience with nonhomosexual MtF transsexualism suggests possible directions for research and treatment for persons who desire limb amputation.
Glick, S J; Hawkins, W G; King, M A; Penney, B C; Soares, E J; Byrne, C L
1992-01-01
The application of stationary restoration techniques to SPECT images assumes that the modulation transfer function (MTF) of the imaging system is shift invariant. It was hypothesized that using intrinsic attenuation correction (i.e., methods which explicitly invert the exponential radon transform) would yield a three-dimensional (3-D) MTF which varies less with position within the transverse slices than the combined conjugate view two-dimensional (2-D) MTF varies with depth. Thus the assumption of shift invariance would become less of an approximation for 3-D post- than for 2-D pre-reconstruction restoration filtering. SPECT acquisitions were obtained from point sources located at various positions in three differently shaped, water-filled phantoms. The data were reconstructed with intrinsic attenuation correction, and 3-D MTFs were calculated. Four different intrinsic attenuation correction methods were compared: (1) exponentially weighted backprojection, (2) a modified exponentially weighted backprojection as described by Tanaka et al. [Phys. Med. Biol. 29, 1489-1500 (1984)], (3) a Fourier domain technique as described by Bellini et al. [IEEE Trans. ASSP 27, 213-218 (1979)], and (4) the circular harmonic transform (CHT) method as described by Hawkins et al. [IEEE Trans. Med. Imag. 7, 135-148 (1988)]. The dependence of the 3-D MTF obtained with these methods, on point source location within an attenuator, and on shape of the attenuator, was studied. These 3-D MTFs were compared to: (1) those MTFs obtained with no attenuation correction, and (2) the depth dependence of the arithmetic mean combined conjugate view 2-D MTFs.(ABSTRACT TRUNCATED AT 250 WORDS)
Evaluation of the impact of light scatter from glistenings in pseudophakic eyes.
DeHoog, Edward; Doraiswamy, Anand
2014-01-01
To study the impact of light scatter from glistenings in pseudophakic eyes using ray tracing in a model eye Department of Research, Advanced Vision Science, Inc., Goleta, California, USA. Mathematical modeling and simulation. A pseudophakic eye model was constructed in Zemax using the Arizona eye model as the basis. The Mie scattering theory was used to describe the intensity and direction of light as it scatters for a spherical particle immersed in a given media (intraocular lens [IOL]). The modeling and evaluation of scatter and modulation transfer function (MTF) were performed for several biomaterials with various size and density of glistenings under scotopic, mesopic, and photopic conditions. As predicted by the Mie theory, the amount of scatter was a function of the relative difference in refractive index between the media and the scatterer, the size of the scatterer, and the volume fraction of the scatterer. The simulation demonstrated that an increase in density of glistenings can lead to a significant drop in the MTF of the IOL and the pseudophakic eye. This effect was more pronounced in IOLs with smaller cavitations, and the observation was consistent for all tested biomaterials. Mathematical modeling demonstrated that glistenings in IOLs will lead to reduction in the MTF of the IOL and the pseudophakic eye. The loss in MTF was more pronounced at high densities and small cavitation sizes across all biomaterials. Inconsistent and poor clinical quantification of glistenings in IOLs may explain some inconsistencies in the literature. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Spies, M; Hahn, A; Kranz, G S; Sladky, R; Kaufmann, U; Hummer, A; Ganger, S; Kraus, C; Winkler, D; Seiger, R; Comasco, E; Windischberger, C; Kasper, S; Lanzenberger, R
2016-09-01
Sex-steroid hormones have repeatedly been shown to influence empathy, which is in turn reflected in resting state functional connectivity (rsFC). Cross-sex hormone treatment in transgender individuals provides the opportunity to examine changes to rsFC over gender transition. We aimed to investigate whether sex-steroid hormones influence rsFC patterns related to unique aspects of empathy, namely emotion recognition and description as well as emotional contagion. RsFC data was acquired with 7Tesla magnetic resonance imaging in 24 male-to-female (MtF) and 33 female-to-male (FtM) transgender individuals before treatment, in addition to 33 male- and 44 female controls. Of the transgender participants, 15 MtF and 20 FtM were additionally assessed after 4 weeks and 4 months of treatment. Empathy scores were acquired at the same time-points. MtF differed at baseline from all other groups and assimilated over the course of gender transition in a rsFC network around the supramarginal gyrus, a region central to interpersonal emotion processing. While changes to sex-steroid hormones did not correlate with rsFC in this network, a sex hormone independent association between empathy scores and rsFC was found. Our results underline that 1) MtF transgender persons demonstrate unique rsFC patterns in a network related to empathy and 2) changes within this network over gender transition are likely related to changes in emotion recognition, -description, and -contagion, and are sex-steroid hormone independent. Copyright © 2016 Elsevier Inc. All rights reserved.
Finger length ratio (2D:4D) in adults with gender identity disorder.
Kraemer, Bernd; Noll, Thomas; Delsignore, Aba; Milos, Gabriella; Schnyder, Ulrich; Hepp, Urs
2009-06-01
From early childhood, gender identity and the 2nd to 4th finger length ratio (2D:4D) are discriminative characteristics between sexes. Both the human brain and 2D:4D may be influenced by prenatal testosterone levels. This calls for an examination of 2D:4D in patients with gender identity disorder (GID) to study the possible influence of prenatal testosterone on gender identity. Until now, the only study carried out on this issue suggests lower prenatal testosterone levels in right-handed male-to-female GID patients (MtF). We compared 2D:4D of 56 GID patients (39 MtF; 17 female-to-male GID patients, FtM) with data from a control sample of 176 men and 190 women. Bivariate group comparisons showed that right hand 2D:4D in MtF was significantly higher (feminized) than in male controls, but similar to female controls. The comparison of 2D:4D ratios of biological women revealed significantly higher (feminized) values for right hands of right handed FtM. Analysis of variance confirmed significant effects for sex and for gender identity on 2D:4D ratios but not for sexual orientation or for the interaction among variables. Our results indirectly point to the possibility of a weak influence of reduced prenatal testosterone as an etiological factor in the multifactorially influenced development of MtF GID. The development of FtM GID seems even more unlikely to be notably influenced by prenatal testosterone.
Saito, Kenta; Arai, Yoshiyuki; Zhang, Jize; Kobayashi, Kentaro; Tani, Tomomi; Nagai, Takeharu
2011-01-01
Laser-scanning confocal microscopy has been employed for exploring structures at subcellular, cellular and tissue level in three dimensions. To acquire the confocal image, a coherent light source, such as laser, is generally required in conventional single-point scanning microscopy. The illuminating beam must be focused onto a small spot with diffraction-limited size, and this determines the spatial resolution of the microscopy system. In contrast, multipoint scanning confocal microscopy using a Nipkow disk enables the use of an incoherent light source. We previously demonstrated successful application of a 100 W mercury arc lamp as a light source for the Yokogawa confocal scanner unit in which a microlens array was coupled with a Nipkow disk to focus the collimated incident light onto a pinhole (Saito et al., Cell Struct. Funct., 33: 133-141, 2008). However, transmission efficiency of incident light through the pinhole array was low because off-axis light, the major component of the incident light, was blocked by the non-aperture area of the disk. To improve transmission efficiency, we propose an optical system in which off-axis light is able to be transmitted through pinholes surrounding the pinhole located on the optical axis of the collimator lens. This optical system facilitates the use of not only the on-axis but also the off-axis light such that the available incident light is considerably improved. As a result, we apply the proposed system to high-speed confocal and multicolor imaging both with a satisfactory signal-to-noise ratio.
Coherent and incoherent phase stabilities of thermoelectric rocksalt IV-VI semiconductor alloys
NASA Astrophysics Data System (ADS)
Doak, Jeff W.; Wolverton, C.
2012-10-01
Nanostructures formed by phase separation improve the thermoelectric figure of merit in lead chalcogenide semiconductor alloys, with coherent nanostructures giving larger improvements than incoherent nanostructures. However, large coherency strains in these alloys drastically alter the thermodynamics of phase stability. Incoherent phase stability can be easily inferred from an equilibrium phase diagram, but coherent phase stability is more difficult to assess experimentally. Therefore, we use density functional theory calculations to investigate the coherent and incoherent phase stability of the IV-VI rocksalt semiconductor alloy systems Pb(S,Te), Pb(Te,Se), Pb(Se,S), (Pb,Sn)Te, (Sn,Ge)Te, and (Ge,Pb)Te. Here we use the term coherent to indicate that there is a common and unbroken lattice between the phases under consideration, and we use the term incoherent to indicate that the lattices of coexisting phases are unconstrained and allowed to take on equilibrium volumes. We find that the thermodynamic ground state of all of the IV-VI pseudobinary systems studied is incoherent phase separation. We also find that the coherency strain energy, previously neglected in studies of these IV-VI alloys, is lowest along [111] (in contrast to most fcc metals) and is a large fraction of the thermodynamic driving force for incoherent phase separation in all systems. The driving force for coherent phase separation is significantly reduced, and we find that coherent nanostructures can only form at low temperatures where kinetics may prohibit their precipitation. Furthermore, by calculating the energies of ordered structures for these systems we find that the coherent phase stability of most IV-VI systems favors ordering over spinodal decomposition. Our results suggest that experimental reports of spinodal decomposition in the IV-VI rocksalt alloys should be re-examined.
Single-exposure color digital holography
NASA Astrophysics Data System (ADS)
Feng, Shaotong; Wang, Yanhui; Zhu, Zhuqing; Nie, Shouping
2010-11-01
In this paper, we report a method for color image reconstruction by recording only one single multi-wavelength hologram. In the recording process, three lasers of different wavelengths emitting in the red, green and blue regions are used for illuminating on the object and the object diffraction fields will arrive at the hologram plane simultaneously. Three reference beams with different spatial angles will interfere with the corresponding object diffraction fields on the hologram plane, respectively. Finally, a series of sub-holograms incoherently overlapped on the CCD to be recorded as a multi-wavelength hologram. Angular division multiplexing is employed to reference beams so that the spatial spectra of the multiple recordings will be separated in the Fourier plane. In the reconstruction process, the multi-wavelength hologram will be Fourier transformed into its Fourier plane, where the spatial spectra of different wavelengths are separated and can be easily extracted by employing frequency filtering. The extracted spectra are used to reconstruct the corresponding monochromatic complex amplitudes, which will be synthesized to reconstruct the color image. For singleexposure recording technique, it is convenient for applications on the real-time image processing fields. However, the quality of the reconstructed images is affected by speckle noise. How to improve the quality of the images needs for further research.
Intonation and gender perception: applications for transgender speakers.
Hancock, Adrienne; Colton, Lindsey; Douglas, Fiacre
2014-03-01
Intonation is commonly addressed in voice and communication feminization therapy, yet empirical evidence of gender differences for intonation is scarce and rarely do studies examine how it relates to gender perception of transgender speakers. This study examined intonation of 12 males, 12 females, six female-to-male, and 14 male-to-female transgender speakers describing a Norman Rockwell image. Several intonation measures were compared between biological gender groups, between perceived gender groups, and between male-to-female (MTF) speakers who were perceived as male, female, or ambiguous gender. Speakers with a larger percentage of utterances with upward intonation and a larger utterance semitone range were perceived as female by listeners, despite no significant differences between the actual intonation of the four gender groups. MTF speakers who do not pass as female appear to use less upward and more downward intonations than female and passing MTF speakers. Intonation has potential for use in transgender communication therapy because it can influence perception to some degree. Copyright © 2014 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Social context of HIV risk behaviours among male-to-female transgenders of colour.
Nemoto, T; Operario, D; Keatley, J; Villegas, D
2004-08-01
To explore the social context of drug use and sexual behaviours that put male-to-female (MTF) transgenders at risk for HIV, focus groups were conducted consisting of African American, Latina and Asian and Pacific Islander MTF transgenders (N = 48) who reside or work in San Francisco, California. Participants were likely to report having unprotected sex with primary partners to signify love and emotional connection, as well as to receive gender validation from their partners. In contrast, viewing sex work with customers as a business encouraged intentious to use condoms. Safer sex intentions with customers were frequently undermined by urgent financial needs, which stemmed from transphobia, employment discrimination and costly procedures associated with gender transition. Participants reported using drugs as a way to cope with or escape life stresses associated with relationships, sex work, transphobia and financial hardship. Interventions with at-risk MTF transgenders should address the interpersonal and social context of unsafe sex and drug use, particularly the unique roles of relationship issues with male partners, stigma, discrimination and community norms regarding sex work and drug use.
Space station interior noise analysis program
NASA Technical Reports Server (NTRS)
Stusnick, E.; Burn, M.
1987-01-01
Documentation is provided for a microcomputer program which was developed to evaluate the effect of the vibroacoustic environment on speech communication inside a space station. The program, entitled Space Station Interior Noise Analysis Program (SSINAP), combines a Statistical Energy Analysis (SEA) prediction of sound and vibration levels within the space station with a speech intelligibility model based on the Modulation Transfer Function and the Speech Transmission Index (MTF/STI). The SEA model provides an effective analysis tool for predicting the acoustic environment based on proposed space station design. The MTF/STI model provides a method for evaluating speech communication in the relatively reverberant and potentially noisy environments that are likely to occur in space stations. The combinations of these two models provides a powerful analysis tool for optimizing the acoustic design of space stations from the point of view of speech communications. The mathematical algorithms used in SSINAP are presented to implement the SEA and MTF/STI models. An appendix provides an explanation of the operation of the program along with details of the program structure and code.
Conception of a cheap infrared camera using a Fresnel lens
NASA Astrophysics Data System (ADS)
Grulois, Tatiana; Druart, Guillaume; Guérineau, Nicolas; Crastes, Arnaud; Sauer, Hervé; Chavel, Pierre
2014-09-01
Today huge efforts are made in the research and industrial areas to design compact and cheap uncooled infrared optical systems for low-cost imagery applications. Indeed, infrared cameras are currently too expensive to be widespread. If we manage to cut their cost, we expect to open new types of markets. In this paper, we will present the cheap broadband microimager we have designed. It operates in the long-wavelength infrared range and uses only one silicon lens at a minimal cost for the manufacturing process. Our concept is based on the use of a thin optics. Therefore inexpensive unconventional materials can be used because some absorption can be tolerated. Our imager uses a thin Fresnel lens. Up to now, Fresnel lenses have not been used for broadband imagery applications because of their disastrous chromatic properties. However, we show that working in a high diffraction order can significantly reduce chromatism. A prototype has been made and the performance of our camera will be discussed. Its characterization has been carried out in terms of modulation transfer function (MTF) and noise equivalent temperature difference (NETD). Finally, experimental images will be presented.
A preliminary optical design for the JANUS camera of ESA's space mission JUICE
NASA Astrophysics Data System (ADS)
Greggio, D.; Magrin, D.; Ragazzoni, R.; Munari, M.; Cremonese, G.; Bergomi, M.; Dima, M.; Farinato, J.; Marafatto, L.; Viotto, V.; Debei, S.; Della Corte, V.; Palumbo, P.; Hoffmann, H.; Jaumann, R.; Michaelis, H.; Schmitz, N.; Schipani, P.; Lara, L.
2014-08-01
The JANUS (Jovis, Amorum ac Natorum Undique Scrutator) will be the on board camera of the ESA JUICE satellite dedicated to the study of Jupiter and its moons, in particular Ganymede and Europa. This optical channel will provide surface maps with plate scale of 15 microrad/pixel with both narrow and broad band filters in the spectral range between 0.35 and 1.05 micrometers over a Field of View 1.72 × 1.29 degrees2. The current optical design is based on TMA design, with on-axis pupil and off-axis field of view. The optical stop is located at the secondary mirror providing an effective collecting area of 7854 mm2 (100 mm entrance pupil diameter) and allowing a simple internal baffling for first order straylight rejection. The nominal optical performances are almost limited by the diffraction and assure a nominal MTF better than 63% all over the whole Field of View. We describe here the optical design of the camera adopted as baseline together with the trade-off that has led us to this solution.
A novel and compact spectral imaging system based on two curved prisms
NASA Astrophysics Data System (ADS)
Nie, Yunfeng; Bin, Xiangli; Zhou, Jinsong; Li, Yang
2013-09-01
As a novel detection approach which simultaneously acquires two-dimensional visual picture and one-dimensional spectral information, spectral imaging offers promising applications on biomedical imaging, conservation and identification of artworks, surveillance of food safety, and so forth. A novel moderate-resolution spectral imaging system consisting of merely two optical elements is illustrated in this paper. It can realize the function of a relay imaging system as well as a 10nm spectral resolution spectroscopy. Compared to conventional prismatic imaging spectrometers, this design is compact and concise with only two special curved prisms by utilizing two reflective surfaces. In contrast to spectral imagers based on diffractive grating, the usage of compound-prism possesses characteristics of higher energy utilization and wider free spectral range. The seidel aberration theory and dispersive principle of this special prism are analyzed at first. According to the results, the optical system of this design is simulated, and the performance evaluation including spot diagram, MTF and distortion, is presented. In the end, considering the difficulty and particularity of manufacture and alignment, an available method for fabrication and measurement is proposed.
Design of space-borne imager with wide field of view based on freeform aberration theory
NASA Astrophysics Data System (ADS)
Shi, Haodong; Zhang, Jizhen; Wang, Lingjie; Zhang, Xin; Jiang, Huilin
2016-10-01
Freeform surfaces have advantages on balancing asymmetric aberration of the unobscured push-broom imager. However, since the conventional paraxial aberration theory is no longer appropriate for the freeform system design, designers are lack of insights on the imaging quality from the freeform aberration distribution. In order to design the freeform optical system efficiently, the contribution and nodal behavior of coma and astigmatism introduced by Standard Zernike polynomial surface are discussed in detail. An unobscured three-mirror optical system with 850 mm effective focal length, 20°× 2° field of view (FOV) is designed. The coma and astigmatism nodal positions are moved into the real-FOV by selecting and optimizing the Zernike terms pointedly, which has balanced the off-axis asymmetric aberration. The results show that the modulation transfer function (MTF) is close to diffraction limit, and the distortion throughout full-FOV is less than 0.25%. At last, a computer-generated hologram (CGH) for freeform surface testing is designed. The CGH design error RMS is lower than λ/1000 at 632.8 nm, which meets the requirements for measurement.
Efficient photonic reformatting of celestial light for diffraction-limited spectroscopy
NASA Astrophysics Data System (ADS)
MacLachlan, D. G.; Harris, R. J.; Gris-Sánchez, I.; Morris, T. J.; Choudhury, D.; Gendron, E.; Basden, A. G.; Spaleniak, I.; Arriola, A.; Birks, T. A.; Allington-Smith, J. R.; Thomson, R. R.
2017-02-01
The spectral resolution of a dispersive astronomical spectrograph is limited by the trade-off between throughput and the width of the entrance slit. Photonic guided wave transitions have been proposed as a route to bypass this trade-off, by enabling the efficient reformatting of incoherent seeing-limited light collected by the telescope into a linear array of single modes: a pseudo-slit which is highly multimode in one axis but diffraction-limited in the dispersion axis of the spectrograph. It is anticipated that the size of a single-object spectrograph fed with light in this manner would be essentially independent of the telescope aperture size. A further anticipated benefit is that such spectrographs would be free of `modal noise', a phenomenon that occurs in high-resolution multimode fibre-fed spectrographs due to the coherent nature of the telescope point spread function (PSF). We seek to address these aspects by integrating a multicore fibre photonic lantern with an ultrafast laser inscribed three-dimensional waveguide interconnect to spatially reformat the modes within the PSF into a diffraction-limited pseudo-slit. Using the CANARY adaptive optics (AO) demonstrator on the William Herschel Telescope, and 1530 ± 80 nm stellar light, the device exhibits a transmission of 47-53 per cent depending upon the mode of AO correction applied. We also show the advantage of using AO to couple light into such a device by sampling only the core of the CANARY PSF. This result underscores the possibility that a fully optimized guided-wave device can be used with AO to provide efficient spectroscopy at high spectral resolution.
GPU acceleration towards real-time image reconstruction in 3D tomographic diffractive microscopy
NASA Astrophysics Data System (ADS)
Bailleul, J.; Simon, B.; Debailleul, M.; Liu, H.; Haeberlé, O.
2012-06-01
Phase microscopy techniques regained interest in allowing for the observation of unprepared specimens with excellent temporal resolution. Tomographic diffractive microscopy is an extension of holographic microscopy which permits 3D observations with a finer resolution than incoherent light microscopes. Specimens are imaged by a series of 2D holograms: their accumulation progressively fills the range of frequencies of the specimen in Fourier space. A 3D inverse FFT eventually provides a spatial image of the specimen. Consequently, acquisition then reconstruction are mandatory to produce an image that could prelude real-time control of the observed specimen. The MIPS Laboratory has built a tomographic diffractive microscope with an unsurpassed 130nm resolution but a low imaging speed - no less than one minute. Afterwards, a high-end PC reconstructs the 3D image in 20 seconds. We now expect an interactive system providing preview images during the acquisition for monitoring purposes. We first present a prototype implementing this solution on CPU: acquisition and reconstruction are tied in a producer-consumer scheme, sharing common data into CPU memory. Then we present a prototype dispatching some reconstruction tasks to GPU in order to take advantage of SIMDparallelization for FFT and higher bandwidth for filtering operations. The CPU scheme takes 6 seconds for a 3D image update while the GPU scheme can go down to 2 or > 1 seconds depending on the GPU class. This opens opportunities for 4D imaging of living organisms or crystallization processes. We also consider the relevance of GPU for 3D image interaction in our specific conditions.
Sourty, Erwan; van Bavel, Svetlana; Lu, Kangbo; Guerra, Ralph; Bar, Georg; Loos, Joachim
2009-06-01
Two purely carbon-based functional polymer systems were investigated by bright-field conventional transmission electron microscopy (CTEM) and high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM). For a carbon black (CB) filled polymer system, HAADF-STEM provides high contrast between the CB agglomerates and the polymer matrix so that details of the interface organization easily can be revealed and assignment of the CB phase is straightforward. For a second system, the functional polymer blend representing the photoactive layer of a polymer solar cell, details of its nanoscale organization could be observed that were not accessible with CTEM. By varying the camera length in HAADF-STEM imaging, the contrast can be enhanced between crystalline and amorphous compounds due to diffraction contrast so that nanoscale interconnections between domains are identified. In general, due to its incoherent imaging characteristics HAADF-STEM allows for reliable interpretation of the data obtained.
Deployable reflector configurations
NASA Astrophysics Data System (ADS)
Meinel, A. B.; Meinel, M. P.; Woolf, N. J.
Both the theoretical reasons for considering a non-circular format for the Large Deployable Reflector, and a potentially realizable concept for such a device, are discussed. The optimum systems for diffraction limited telescopes with incoherent detection have either a single filled aperture, or two such apertures as an interferometer to synthesize a larger aperture. For a single aperture of limited area, a reflector in the form of a slot can be used to give increased angular resolution. It is shown how a 20 x 8 meter telescope can be configured to fit the Space Shuttle bay, and deployed with relatively simple operations. The relationship between the sunshield design and the inclination of the orbit is discussed. The possible use of the LDR as a basic module to permit the construction of supergiant space telescopes and interferometers both for IR/submm studies and for the entire ultraviolet through mm wave spectral region is discussed.
Deployable reflector configurations. [for space telescope
NASA Technical Reports Server (NTRS)
Meinel, A. B.; Meinel, M. P.; Woolf, N. J.
1983-01-01
Both the theoretical reasons for considering a non-circular format for the Large Deployable Reflector, and a potentially realizable concept for such a device, are discussed. The optimum systems for diffraction limited telescopes with incoherent detection have either a single filled aperture, or two such apertures as an interferometer to synthesize a larger aperture. For a single aperture of limited area, a reflector in the form of a slot can be used to give increased angular resolution. It is shown how a 20 x 8 meter telescope can be configured to fit the Space Shuttle bay, and deployed with relatively simple operations. The relationship between the sunshield design and the inclination of the orbit is discussed. The possible use of the LDR as a basic module to permit the construction of supergiant space telescopes and interferometers both for IR/submm studies and for the entire ultraviolet through mm wave spectral region is discussed.
Optical Signal Processing: Poisson Image Restoration and Shearing Interferometry
NASA Technical Reports Server (NTRS)
Hong, Yie-Ming
1973-01-01
Optical signal processing can be performed in either digital or analog systems. Digital computers and coherent optical systems are discussed as they are used in optical signal processing. Topics include: image restoration; phase-object visualization; image contrast reversal; optical computation; image multiplexing; and fabrication of spatial filters. Digital optical data processing deals with restoration of images degraded by signal-dependent noise. When the input data of an image restoration system are the numbers of photoelectrons received from various areas of a photosensitive surface, the data are Poisson distributed with mean values proportional to the illuminance of the incoherently radiating object and background light. Optical signal processing using coherent optical systems is also discussed. Following a brief review of the pertinent details of Ronchi's diffraction grating interferometer, moire effect, carrier-frequency photography, and achromatic holography, two new shearing interferometers based on them are presented. Both interferometers can produce variable shear.
Rius, Manuel; Bolea, Mario; Mora, José; Ortega, Beatriz; Capmany, José
2015-05-18
We experimentally demonstrate, for the first time, a chirped microwave pulses generator based on the processing of an incoherent optical signal by means of a nonlinear dispersive element. Different capabilities have been demonstrated such as the control of the time-bandwidth product and the frequency tuning increasing the flexibility of the generated waveform compared to coherent techniques. Moreover, the use of differential detection improves considerably the limitation over the signal-to-noise ratio related to incoherent processing.
Coherent vs. incoherent pairing in 2D systems near magnetic instability
NASA Astrophysics Data System (ADS)
Abanov, Ar.; Chubukov, A. V.; Finkel'stein, A. M.
2001-05-01
We study the superconductivity in 2D fermionic systems near antiferromagnetic instability, assuming that the pairing is mediated by spin fluctuations. This pairing involves fully incoherent fermions and diffusive spin excitations. We show that the competition between fermionic incoherence and strong pairing interaction yields the pairing instability temperature Tins which increases and saturates as the magnetic correlation length ξ → ∞. We argue that in this quantum-critical regime the pairing problem is qualitatively different from the BCS one.
Proof of the Feasibility of Coherent and Incoherent Schemes for Pumping a Gamma-Ray Laser
1988-07-01
DIP!; ilLE-CWPj AD-A 799 638 The University of Texas at DallasCenter for Quantlin, Electronics The Gamma-Ray Laser Project Quarterly Report April...AND INCOHERENT SCHEMES FOR PUMPING A GAMMA-RAY LASER Principal Investigator: Carl B. Collins The University of Texas at Dallas Center for Quantum...FEASIBILITY OF Quarterly Technical Progress COHERENT AND INCOHERENT SCHEMES /I/RR - 61WARA FOR PUMPING A GAMMA-RAY LASER 6.PERFORMINO ORG. REPORT NUMBER
NASA Astrophysics Data System (ADS)
van Leunen, J. A. J.; Dreessen, J.
1984-05-01
The result of a measurement of the modulation transfer function is only useful as long as it is accompanied by a complete description of all relevant measuring conditions involved. For this reason it is necessary to file a full description of the relevant measuring conditions together with the results. In earlier times some of our results were rendered useless because some of the relevant measuring conditions were accidentally not written down and were forgotten. This was mainly due to the lack of concensus about which measuring conditions had to be filed together with the result of a measurement. One way to secure uniform and complete archiving of measuring conditions and results is to automate the data handling. An attendent advantage of automation of data handling is that it does away with the time-consuming correction of rough measuring results. The automation of the data handling was accomplished with rather cheap desktop computers, which were powerfull enough, however, to allow us to automate the measurement as well. After automation of the data handling we started with automatic collection of rough measurement data. Step by step we extended the automation by letting the desktop computer control more and more of the measuring set-up. At present the desktop computer controls all the electrical and most of the mechanical measuring conditions. Further it controls and reads the MTF measuring instrument. Focussing and orientation optimization can be fully automatic, semi-automatic or completely manual. MTF measuring results can be collected automatically but they can also be typed in by hand. Due to the automation we are able to implement proper archival of measuring results together with all necessary measuring conditions. The improved measuring efficiency made it possible to increase the number of routine measurements done in the same time period by an order of magnitude. To our surprise the measuring accuracy also improved by a factor of two. This was due to the much better reproducibility of the automatic optimization, which resulted in better reproducibility of the measurement result. Another advantage of the automation is that the programs that control the data handling and the automatic measurement are "user friendly". They guide the operator through the measuring procedure using information from earlier measurements of equivalent test specimens. This makes it possible to let routine measurements be done by much less skilled assistants. It also removes much of the tedious routine labour normally involved in MTF measurements. It can be concluded that automation of MTF measurements as described in the foregoing enhances the usefulness of MTF results as well as reducing the cost of MTF measurements.
Beam cleaning of an incoherent laser via plasma Raman amplification
Edwards, Matthew R.; Qu, Kenan; Mikhailova, Julia M.; ...
2017-09-25
We show that backward Raman amplification in plasma can efficiently compress a temporally incoherent pump laser into an intense coherent amplified seed pulse, provided that the correlation time of the pump is longer than the inverse plasma frequency. One analytical theory for Raman amplification using pump beams with different correlation functions is developed and compared to numerical calculations and particle-in-cell simulations. Since incoherence on scales shorter than the instability growth time suppresses spontaneous noise amplification, we point out a broad regime where quasi-coherent sources may be used as efficient low-noise Raman amplification pumps. As the amplified seed is coherent, Ramanmore » amplification provides an additional a beam-cleaning mechanism for removing incoherence. At near-infrared wavelengths, finite coherence times as short as 50 fs allow amplification with only minor losses in efficiency.« less
Beam cleaning of an incoherent laser via plasma Raman amplification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edwards, Matthew R.; Qu, Kenan; Mikhailova, Julia M.
We show that backward Raman amplification in plasma can efficiently compress a temporally incoherent pump laser into an intense coherent amplified seed pulse, provided that the correlation time of the pump is longer than the inverse plasma frequency. One analytical theory for Raman amplification using pump beams with different correlation functions is developed and compared to numerical calculations and particle-in-cell simulations. Since incoherence on scales shorter than the instability growth time suppresses spontaneous noise amplification, we point out a broad regime where quasi-coherent sources may be used as efficient low-noise Raman amplification pumps. As the amplified seed is coherent, Ramanmore » amplification provides an additional a beam-cleaning mechanism for removing incoherence. At near-infrared wavelengths, finite coherence times as short as 50 fs allow amplification with only minor losses in efficiency.« less
Rivetti, Stefano; Lanconelli, Nico; Bertolini, Marco; Acchiappati, Domenico
2011-08-01
Here, we present a physical and psychophysical characterization of a new clinical unit (named AcSelerate) for digital radiography based on a thick a-Se layer. We also compared images acquired with and without a software filter (named CRF) developed for reducing sharpness and noise of the images and making them similar to images coming from traditional computed radiography systems. The characterization was achieved in terms of physical figures of merit [modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE)], and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images). We accomplished measurements with four standard beam conditions: RAQ3, RQA5, RQA7, and RQA9. The system shows an excellent MTF (about 50% at the Nyquist frequency). The DQE is about 55% at 0.5 lp/mm and above 20% at the Nyquist frequency and is almost independent from exposure. The contrast-detail curves are comparable to some of the best published data for other systems devoted to imaging in general radiography. The CRF filter influences both the MTF and NPS, but it does lead to very small changes on DQE. Also the visibility of CDRAD details is basically unaltered, when the filter is activated. As normally happens with detector based on direct conversion, the system presents an excellent MTF. The improved efficiency caused by the thick layer allows getting good noise characteristics and DQE results better (about 10% on average) than many of the computed radiography (CR) systems and comparable to those obtained by the best systems for digital radiography available on the market.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bauer, Bruno, S.; Siemon, Richard, E.
2008-10-22
We are pleased to report important progress in experimentally characterizing and numerically modeling the transformation into plasma of walls subjected to pulsed megagauss magnetic fields. Understanding this is important to Magnetized Target Fusion (MTF) because an important limitation to the metal liner approach to MTF comes from the strong eddy current heating on the surface of the metal liner. This has intriguing non-linear aspects when the magnetic field is in the megagauss regime as needed for MTF, and may limit the magnetic field in an MTF implosion. Many faculty, students, and staff have contributed to this work, and, implicitly ormore » explicitly, to this report. Contributors include, in addition to the PIs, Andrey Esaulov, Stephan Fuelling, Irvin Lindemuth, Volodymyr Makhin, Ioana Paraschiv, Milena Angelova, Tom Awe, Tasha Goodrich, Arunkumar Prasadam, Andrew Oxner, Bruno Le Galloudec, Radu Presura, and Vladimir Ivanov. Highlights of the progress made during the grant include: • 12 articles published, and 44 conference and workshop presentations made, on a broad range of issues related to this project; • An ongoing experiment that uses the 1 MA, 100-ns Zebra z-pinch at UNR to apply 2 5 megagauss to a variety of metal surfaces, examining plasma formation and evolution; • Numerical simulation studies of the 1-MA Zebra, and potential Shiva Star and Atlas experiments that include realistic equations of state and radiation effects, using a variety of tables. • Collaboration with other groups doing simulations of this experiment at LANL, VNIIEF, SNL, and NumerEx leading to a successful international workshop at UNR in the spring of 2008.« less
Dura-Trave, T; Yoldi-Petri, M E; Zardoya-Santos, P
2011-09-01
To perform a developmental analysis of the anthropometric variables of a group of patients diagnosed with attention deficit hyperactivity disorder (ADHD) in order to determine the repercussions of treatment with osmotic controlled-release methylphenidate (MTF-OROS). The medical records of 187 patients with ADHD under treatment with MTF-OROS over a period of 30 months were reviewed. Data collected included weight, height and body mass index at diagnosis (baseline) and at 6, 12, 18, 24 and 30 months' follow-up. The mean age at diagnosis was 8.14 ± 1.6 years. The dose of MTF-OROS was progressively increased until 36.9 ± 12.1 mg/day (1.05 mg/kg/day) at day 30 of the follow-up. At diagnosis, 34.9% of patients had a deficient nutritional situation (subnutrition or malnutrition), which affected 50.3% of the patients at 30 months. The baseline value for weight (Z-score) progressively decreased during treatment until values that were significantly lower than the baseline value at 12 months were reached (p < 0.05); these values remained significantly lower until 30 months. The baseline value for height (Z-score) also progressively decreased during treatment until values that were significantly lower than the baseline value at 24 and 30 months were reached (p < 0.05). At the time they were diagnosed with ADHD, one out of every three patients was in a deficient nutritional situation (subnutrition or malnutrition). Continued treatment with MTF-OROS for 30 months had a negative influence on height, which could perhaps be attenuated by improving the patients' nutrition.
MFP scanner diagnostics using a self-printed target to measure the modulation transfer function
NASA Astrophysics Data System (ADS)
Wang, Weibao; Bauer, Peter; Wagner, Jerry; Allebach, Jan P.
2014-01-01
In the current market, reduction of warranty costs is an important avenue for improving profitability by manufacturers of printer products. Our goal is to develop an autonomous capability for diagnosis of printer and scanner caused defects with mid-range laser multifunction printers (MFPs), so as to reduce warranty costs. If the scanner unit of the MFP is not performing according to specification, this issue needs to be diagnosed. If there is a print quality issue, this can be diagnosed by printing a special test page that is resident in the firmware of the MFP unit, and then scanning it. However, the reliability of this process will be compromised if the scanner unit is defective. Thus, for both scanner and printer image quality issues, it is important to be able to properly evaluate the scanner performance. In this paper, we consider evaluation of the scanner performance by measuring its modulation transfer function (MTF). The MTF is a fundamental tool for assessing the performance of imaging systems. Several ways have been proposed to measure the MTF, all of which require a special target, for example a slanted-edge target. It is unacceptably expensive to ship every MFP with such a standard target, and to expect that the customer can keep track of it. To reduce this cost, in this paper, we develop new approach to this task. It is based on a self-printed slanted-edge target. Then, we propose algorithms to improve the results using a self-printed slanted-edge target. Finally, we present experimental results for MTF measurement using self-printed targets and compare them to the results obtained with standard targets.
Kanti, V; Hillmann, K; Kottner, J; Stroux, A; Canfield, D; Blume-Peytavi, U
2016-07-01
Topical minoxidil formulations have been shown to be effective in treating androgenetic alopecia (AGA) for 12 months. Efficacy and safety in both frontotemporal and vertex regions over longer application periods have not been studied so far. To evaluate the effect of 5% minoxidil topical foam (5% MTF) in the frontotemporal and vertex areas in patients with moderate AGA over 104 weeks. An 80-week, open-label extension phase was performed, following a 24-week randomized, double-blind, placebo-controlled study in men with AGA grade IIIvertex to VI. Group 1 (n = 22) received ongoing 5% MTF for 104 weeks, Group 2 (n = 23) received placebo topical foam (plaTF) until week 24, followed by 5% MTF until week 104 during the extension phase. Frontotemporal and vertex target area non-vellus hair counts (f-TAHC, v-TAHC) and cumulative hair width (f-TAHW, v-TAHW) were assessed at baseline and at weeks 24, 52, 76 and 104. In Group 1, f-TAHW and f-TAHC showed a statistically significant increase from baseline to week 52 and week 76, respectively, returning to values comparable to baseline at week 104. No significant differences were found between baseline and week 104 in v-TAHC in Group 1 as well as f-TAHC, v-TAHC, f-TAHW and v-TAHW values in Group 2. 5% MTF is effective in stabilizing hair density, hair width and scalp coverage in both frontotemporal and vertex areas over an application period of 104 weeks, while showing a good safety and tolerability profile with a low rate of irritant contact dermatitis. © 2015 European Academy of Dermatology and Venereology.
Hubbard, Joanna K; Potts, Macy A; Couch, Brian A
2017-01-01
Assessments represent an important component of undergraduate courses because they affect how students interact with course content and gauge student achievement of course objectives. To make decisions on assessment design, instructors must understand the affordances and limitations of available question formats. Here, we use a crossover experimental design to identify differences in how multiple-true-false (MTF) and free-response (FR) exam questions reveal student thinking regarding specific conceptions. We report that correct response rates correlate across the two formats but that a higher percentage of students provide correct responses for MTF questions. We find that MTF questions reveal a high prevalence of students with mixed (correct and incorrect) conceptions, while FR questions reveal a high prevalence of students with partial (correct and unclear) conceptions. These results suggest that MTF question prompts can direct students to address specific conceptions but obscure nuances in student thinking and may overestimate the frequency of particular conceptions. Conversely, FR questions provide a more authentic portrait of student thinking but may face limitations in their ability to diagnose specific, particularly incorrect, conceptions. We further discuss an intrinsic tension between question structure and diagnostic capacity and how instructors might use multiple formats or hybrid formats to overcome these obstacles. © 2017 J. K. Hubbard et al. CBE—Life Sciences Education © 2017 The American Society for Cell Biology. This article is distributed by The American Society for Cell Biology under license from the author(s). It is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).
Benson, Sarah; Downey, Luke A; Stough, Con; Wetherell, Mark; Zangara, Andrea; Scholey, Andrew
2014-04-01
Little research exists in humans concerning the anxiolytic, antidepressant, sedative, and adaptogenic actions the traditional Ayurvedic medicine Bacopa monnieri (BM) possesses in addition to its documented cognitive-enhancing effects. Preclinical work has identified a number of acute anxiolytic, nootropic, and adaptogenic effects of BM that may also co-occur in humans. The current double-blind, placebo-controlled cross-over study assessed the acute effects of a specific extract of BM (KeenMind® - CDRI 08) in normal healthy participants during completion of a multitasking framework (MTF). Seventeen healthy volunteers completed the MTF, at baseline, then 1 h and 2 h after consuming a placebo, 320 mg BM and 640 mg of BM. Treatments were separated by a 7-day washout with order determined by Latin Square. Outcome measures included cognitive outcomes from the MTF, with mood and salivary cortisol measured before and after each completion of the MTF. Change from baseline scores indicated positive cognitive effects, notably at both 1 h post and 2 h post BM consumption on the Letter Search and Stroop tasks, suggesting an earlier nootropic effect of BM than previously investigated. There were also some positive mood effects and reduction in cortisol levels, pointing to a physiological mechanism for stress reduction associated with BM consumption. It was concluded that acute BM supplementation produced some adaptogenic and nootropic effects that need to be replicated in a larger sample and in isolation from stressful cognitive tests in order to quantify the magnitude of these effects. The study was registered with the Australian and New Zealand Clinical Trials Registry (ACTRN12612000834853). Copyright © 2013 John Wiley & Sons, Ltd.
A novel EPID design for enhanced contrast and detective quantum efficiency
NASA Astrophysics Data System (ADS)
Rottmann, Joerg; Morf, Daniel; Fueglistaller, Rony; Zentai, George; Star-Lack, Josh; Berbeco, Ross
2016-09-01
Beams-eye-view imaging applications such as real-time soft-tissue motion estimation are hindered by the inherently low image contrast of electronic portal imaging devices (EPID) currently available for clinical use. We introduce and characterize a novel EPID design that provides substantially increased detective quantum efficiency (DQE), contrast-to-noise ratio (CNR) and sensitivity without degradation in spatial resolution. The prototype design features a stack of four conventional EPID layers combined with low noise integrated readout electronics. Each layer consists of a copper plate, a scintillator (\\text{G}{{\\text{d}}2}{{\\text{O}}2}{{\\text{S}}{}}\\text{:Tb} ) and a photodiode/TFT-switch (aSi:H). We characterize the prototype’s signal response to a 6 MV photon beam in terms of modulation transfer function (MTF), DQE and CNR. The presampled MTF is estimated using a slanted slit technique, the DQE is calculated from measured normalized noise power spectra (nNPS) and the MTF and CNR is estimated using a Las Vegas contrast phantom. The prototype has been designed and built to be interchangeable with the current clinical EPID on the Varian TrueBeam platform (AS-1200) in terms of size and data output specifications. Performance evaluation is conducted in absolute values as well as in relative terms using the Varian AS-1200 EPID as a reference detector. A fivefold increase of DQE(0) to about 6.7% was observed by using the four-layered design versus the AS-1200 reference detector. No substantial differences are observed between each layer’s individual MTF and the one for all four layers operating combined indicating that defocusing due to beam divergence is negligible. Also, using four layers instead of one increases the signal to noise ratio by a factor of 1.7.
Reisner, Sari L.; Vetters, Ralph; Leclerc, M; Zaslow, Shayne; Wolfrum, Sarah; Shumer, Daniel; Mimiaga, Matthew J.
2014-01-01
Purpose Transgender youth represent a vulnerable population at risk for negative mental health outcomes including depression, anxiety, self-harm, and suicidality. Limited data exists to compare the mental health of transgender adolescents and emerging adults to cisgender youth accessing community-based clinical services; the current study aimed to fill this gap. Methods A retrospective cohort study of electronic health record (EHR) data from 180 transgender patients age 12–29 years seen between 2002–2011 at a Boston-based community health center was performed. The 106 female-to-male (FTM) and 74 male-to-female (MTF) patients were matched on gender identity, age, visit date, and race/ethnicity to cisgender controls. Mental health outcomes were extracted and analyzed using conditional logistic regression models. Logistic regression models compared FTM to MTF youth on mental health outcomes. Results The sample (n=360) had a mean age of 19.6 (SD=3.0); 43% white, 33% racial/ethnic minority, and 24% race/ethnicity unknown. Compared to cisgender matched controls, transgender youth had a two- to three-fold increased risk of depression, anxiety disorder, suicidal ideation, suicide attempt, self-harm without lethal intent, and both inpatient and outpatient mental health treatment (all p<0.05). No statistically significant differences in mental health outcomes were observed comparing FTM and MTF patients, adjusting for age, race/ethnicity, and hormone use. Conclusions Transgender youth were found to have a disparity in negative mental health outcomes compared to cisgender youth, with equally high burden in FTM and MTF patients. Identifying gender identity differences in clinical settings and providing appropriate services and supports are important steps in addressing this disparity. PMID:25577670
Reisner, Sari L; Vetters, Ralph; Leclerc, M; Zaslow, Shayne; Wolfrum, Sarah; Shumer, Daniel; Mimiaga, Matthew J
2015-03-01
Transgender youth represent a vulnerable population at risk for negative mental health outcomes including depression, anxiety, self-harm, and suicidality. Limited data exist to compare the mental health of transgender adolescents and emerging adults to cisgender youth accessing community-based clinical services; the present study aimed to fill this gap. A retrospective cohort study of electronic health record data from 180 transgender patients aged 12-29 years seen between 2002 and 2011 at a Boston-based community health center was performed. The 106 female-to-male (FTM) and 74 male-to-female (MTF) patients were matched on gender identity, age, visit date, and race/ethnicity to cisgender controls. Mental health outcomes were extracted and analyzed using conditional logistic regression models. Logistic regression models compared FTM with MTF youth on mental health outcomes. The sample (N = 360) had a mean age of 19.6 years (standard deviation, 3.0); 43% white, 33% racial/ethnic minority, and 24% race/ethnicity unknown. Compared with cisgender matched controls, transgender youth had a twofold to threefold increased risk of depression, anxiety disorder, suicidal ideation, suicide attempt, self-harm without lethal intent, and both inpatient and outpatient mental health treatment (all p < .05). No statistically significant differences in mental health outcomes were observed comparing FTM and MTF patients, adjusting for age, race/ethnicity, and hormone use. Transgender youth were found to have a disparity in negative mental health outcomes compared with cisgender youth, with equally high burden in FTM and MTF patients. Identifying gender identity differences in clinical settings and providing appropriate services and supports are important steps in addressing this disparity. Copyright © 2015 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
Favazza, Christopher P.; Duan, Xinhui; Zhang, Yi; Yu, Lifeng; Leng, Shuai; Kofler, James M.; Bruesewitz, Michael R.; McCollough, Cynthia H.
2015-01-01
Through this investigation we developed a methodology to evaluate and standardize CT image quality from routine abdomen protocols across different manufacturers and models. The influence of manufacturer-specific automated exposure control systems on image quality was directly assessed to standardize performance across a range of patient sizes. We evaluated 16 CT scanners across our health system, including Siemens, GE, and Toshiba models. Using each practice’s routine abdomen protocol, we measured spatial resolution, image noise, and scanner radiation output (CTDIvol). Axial and in-plane spatial resolutions were assessed through slice sensitivity profile (SSP) and modulation transfer function (MTF) measurements, respectively. Image noise and CTDIvol values were obtained for three different phantom sizes. SSP measurements demonstrated a bimodal distribution in slice widths: an average of 6.2 ± 0.2 mm using GE’s “Plus” mode reconstruction setting and 5.0 ± 0.1 mm for all other scanners. MTF curves were similar for all scanners. Average spatial frequencies at 50%, 10%, and 2% MTF values were 3.24 ± 0.37, 6.20 ± 0.34, and 7.84 ± 0.70 lp/cm, respectively. For all phantom sizes, image noise and CTDIvol varied considerably: 6.5–13.3 HU (noise) and 4.8–13.3 mGy (CTDIvol) for the smallest phantom; 9.1–18.4 HU and 9.3–28.8 mGy for the medium phantom; and 7.8–23.4 HU and 16.0–48.1 mGy for the largest phantom. Using these measurements and benchmark SSP, MTF, and image noise targets, CT image quality can be standardized across a range of patient sizes. PMID:26459751
Rodríguez-Ruiz, A; Castillo, M; Garayoa, J; Chevalier, M
2016-06-01
The aim of this work was to research and evaluate the performance of three different digital breast tomosynthesis (DBT) systems in the clinical environment (Siemens Mammomat Inspiration, Hologic Selenia Dimensions, and Fujifilm Amulet Innovality). The characterization included the study of the detector, the automatic exposure control, and the resolution of DBT projections and reconstructed planes. The modulation transfer function (MTF) of the DBT projections was measured with a 1mm thick steel edge, showing a strong anisotropy (30-40% lower MTF0.5 frequencies in the tube travel direction). The in-plane MTF0.5, measured with a 25μm tungsten wire, ranges from 1.3 to 1.8lp/mm in the tube-travel direction and between 2.4 and 3.7lp/mm in the chest wall-nipple. In the latter direction, the MTF peak shift is more emphasized for large angular range systems (2.0 versus 1.0lp/mm). In-depth resolution of the planes, via the full width at half maximum (FWHM) from the point spread function of a 25μm tungsten wire, is not only influenced by angular range and yields 1.3-4.6mm among systems. The artifact spread function from 1mm diameter tungsten beads depends mainly on angular range, yielding two tendencies whether large (FWHM is 4.5mm) or small (FWHM is 10mm) angular range is used. DBT delivers per scan a mean glandular dose between 1.4 and 2.7mGy for a 45mm thick polymethyl methacrylate (PMMA) block. In conclusion, we have identified and analysed specific metrics that can be used for quality assurance of DBT systems. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Berggren, Karl; Cederström, Björn; Lundqvist, Mats; Fredenberg, Erik
2018-02-01
Digital breast tomosynthesis (DBT) is an emerging tool for breast-cancer screening and diagnostics. The purpose of this study is to present a second-generation photon-counting slit-scanning DBT system and compare it to the first-generation system in terms of geometry and image quality. The study presents the first image-quality measurements on the second-generation system. The geometry of the new system is based on a combined rotational and linear motion, in contrast to a purely rotational scan motion in the first generation. In addition, the calibration routines have been updated. Image quality was measured in the center of the image field in terms of in-slice modulation transfer function (MTF), artifact spread function (ASF), and in-slice detective quantum efficiency (DQE). Images were acquired using a W/Al 29 kVp spectrum at 13 mAs with 2 mm Al additional filtration and reconstructed using simple back-projection. The in-slice 50% MTF was improved in the chest-mammilla direction, going from 3.2 to 3.5 lp/mm, and the zero-frequency DQE increased from 0.71 to 0.77. The MTF and ASF were otherwise found to be on par for the two systems. The new system has reduced in-slice variation of the tomographic angle. The new geometry is less curved, which reduces in-slice tomographic-angle variation, and increases the maximum compression height, making the system accessible for a larger population. The improvements in MTF and DQE were attributed to the updated calibration procedures. We conclude that the second-generation system maintains the key features of the photon-counting system while maintaining or improving image quality and improving the maximum compression height. © 2017 American Association of Physicists in Medicine.
Neutron Polarization Analysis for Biphasic Solvent Extraction Systems
Motokawa, Ryuhei; Endo, Hitoshi; Nagao, Michihiro; ...
2016-06-16
Here we performed neutron polarization analysis (NPA) of extracted organic phases containing complexes, comprised of Zr(NO 3) 4 and tri-n-butyl phosphate, which enabled decomposition of the intensity distribution of small-angle neutron scattering (SANS) into the coherent and incoherent scattering components. The coherent scattering intensity, containing structural information, and the incoherent scattering compete over a wide range of magnitude of scattering vector, q, specifically when q is larger than q* ≈ 1/R g, where R g is the radius of gyration of scatterer. Therefore, it is important to determine the incoherent scattering intensity exactly to perform an accurate structural analysis frommore » SANS data when R g is small, such as the aforementioned extracted coordination species. Although NPA is the best method for evaluating the incoherent scattering component for accurately determining the coherent scattering in SANS, this method is not used frequently in SANS data analysis because it is technically challenging. In this study, we successfully demonstrated that experimental determination of the incoherent scattering using NPA is suitable for sample systems containing a small scatterer with a weak coherent scattering intensity, such as extracted complexes in biphasic solvent extraction systems.« less
Blau, Samuel M.; Bennett, Doran I. G.; Kreisbeck, Christoph; Scholes, Gregory D.; Aspuru-Guzik, Alán
2018-01-01
The mechanisms controlling excitation energy transport (EET) in light-harvesting complexes remain controversial. Following the observation of long-lived beats in 2D electronic spectroscopy of PC645, vibronic coherence, the delocalization of excited states between pigments supported by a resonant vibration, has been proposed to enable direct excitation transport from the highest-energy to the lowest-energy pigments, bypassing a collection of intermediate states. Here, we instead show that for phycobiliprotein PC645 an incoherent vibronic transport mechanism is at play. We quantify the solvation dynamics of individual pigments using ab initio quantum mechanics/molecular mechanics (QM/MM) nuclear dynamics. Our atomistic spectral densities reproduce experimental observations ranging from absorption and fluorescence spectra to the timescales and selectivity of down-conversion observed in transient absorption measurements. We construct a general model for vibronic dimers and establish the parameter regimes of coherent and incoherent vibronic transport. We demonstrate that direct down-conversion in PC645 proceeds incoherently, enhanced by large reorganization energies and a broad collection of high-frequency vibrations. We suggest that a similar incoherent mechanism is appropriate across phycobiliproteins and represents a potential design principle for nanoscale control of EET. PMID:29588417
Photo-thermal processing of semiconductor fibers and thin films
NASA Astrophysics Data System (ADS)
Gupta, Nishant
Furnace processing and rapid thermal processing (RTP) have been an integral part of several processing steps in semiconductor manufacturing. The performance of RTP techniques can be improved many times by exploiting quantum photo-effects of UV and vacuum ultraviolet (VUV) photons in thermal processing and this technique is known as rapid photo-thermal processing (RPP). As compared to furnace processing and RTP, RPP provides higher diffusion coefficient, lower stress and lower microscopic defects. In this work, a custom designed automated photo assisted processing system was built from individual parts and an incoherent light source. This photo-assisted processing system is used to anneal silica clad silicon fibers and deposit thin-films. To the best of our knowledge, incoherent light source based rapid photo-thermal processing (RPP) was used for the first time to anneal glass-clad silicon core optical fibers. X-ray diffraction examination, Raman spectroscopy and electrical measurements showed a considerable enhancement of structural and crystalline properties of RPP treated silicon fibers. Photons in UV and vacuum ultraviolet (VUV) regions play a very important role in improving the bulk and carrier transport properties of RPP-treated silicon optical fibers, and the resultant annealing permits a path forward to in situ enhancement of the structure and properties of these new crystalline core optical fibers. To explore further applications of RPP, thin-films of Calcium Copper Titanate (CaCu3Ti4O12) or CCTO and Copper (I) Oxide (Cu2O) were also deposited using photo-assisted metal-organic chemical vapor deposition (MOCVD) on Si/SiO2 and n-Si substrate respectively. CCTO is one of the most researched giant dielectric constant materials in recent years. The given photo-assisted MOCVD approach provided polycrystalline CCTO growth on a SiO2 surface with grain sizes as large as 410 nm. Copper (I) oxide (Cu2O) is a direct band gap semiconductor with p-type conductivity and is a potential candidate for multi-junction solar cells. X-ray diffraction study revealed a preferred orientation, as (200) oriented crystals of Cu2O are grown on both substrates. Also, electrical characterization of Cu2O/n-Si devices showed the lowest saturation current density of 1.5x10-12 A/cm 2 at zero bias. As a result, photo-assisted thermal processing has the potential of making the process more effective with enhanced device performance.
Incoherent transport for phases that spontaneously break translations
NASA Astrophysics Data System (ADS)
Donos, Aristomenis; Gauntlett, Jerome P.; Griffin, Tom; Ziogas, Vaios
2018-04-01
We consider phases of matter at finite charge density which spontaneously break spatial translations. Without taking a hydrodynamic limit we identify a boost invariant incoherent current operator. We also derive expressions for the small frequency behaviour of the thermoelectric conductivities generalising those that have been derived in a translationally invariant context. Within holographic constructions we show that the DC conductivity for the incoherent current can be obtained from a solution to a Stokes flow for an auxiliary fluid on the black hole horizon combined with specific thermodynamic quantities associated with the equilibrium black hole solutions.
Gain statistics of a fiber optical parametric amplifier with a temporally incoherent pump.
Xu, Y Q; Murdoch, S G
2010-03-15
We present an investigation of the statistics of the gain fluctuations of a fiber optical parametric amplifier pumped with a temporally incoherent pump. We derive a simple expression for the probability distribution of the gain of the amplified optical signal. The gain statistics are shown to be a strong function of the signal detuning and allow the possibility of generating optical gain distributions with controllable long-tails. Very good agreement is found between this theory and the experimentally measured gain distributions of an incoherently pumped amplifier.
NASA Astrophysics Data System (ADS)
Abbasabadi, Majid; Sahrai, Mostafa
2018-01-01
We investigated the propagation of an electromagnetic pulse through a one-dimensional photonic crystal doped with quantum-dot (QD) molecules in a defect layer. The QD molecules behave as a three-level quantum system and are driven by a coherent probe laser field and an incoherent pump field. No coherent coupling laser fields were introduced, and the coherence was created by the interdot tunnel effect. Further studied was the effect of tunneling and incoherent pumping on the group velocity of the transmitted and reflected probe pulse.
Jeong, Kyeong-Min; Kim, Hee-Seung; Hong, Sung-In; Lee, Sung-Keun; Jo, Na-Young; Kim, Yong-Soo; Lim, Hong-Gi; Park, Jae-Hyeung
2012-10-08
Speed enhancement of integral imaging based incoherent Fourier hologram capture using a graphic processing unit is reported. Integral imaging based method enables exact hologram capture of real-existing three-dimensional objects under regular incoherent illumination. In our implementation, we apply parallel computation scheme using the graphic processing unit, accelerating the processing speed. Using enhanced speed of hologram capture, we also implement a pseudo real-time hologram capture and optical reconstruction system. The overall operation speed is measured to be 1 frame per second.
[Design of a Component and Transmission Imaging Spectrometer].
Sun, Bao-peng; Zhang, Yi; Yue, Jiang; Han, Jing; Bai, Lian-fa
2015-05-01
In the reflection-based imaging spectrometer, multiple reflection(diffraction) produces stray light and it is difficult to assemble. To address that, a high performance transmission spectral imaging system based on general optical components was developed. On the basis of simple structure, the system is easy to assemble. And it has wide application and low cost compared to traditional imaging spectrometers. All components in the design can be replaced according to different application situations, having high degree of freedom. In order to reduce the influence of stray light, a method based on transmission was introduced. Two sets of optical systems with different objective lenses were simulated; the parameters such as distortion, MTF and aberration.were analyzed and optimized in the ZEMAX software. By comparing the performance of system with different objective len 25 and 50 mm, it can be concluded that the replacement of telescope lens has little effect on imaging quality of whole system. An imaging spectrometer is developed successfully according design parameters. The telescope lens uses double Gauss structures, which is beneficial to reduce field curvature and distortion. As the craftsmanship of transmission-type plane diffraction grating is mature, it can be used without modification and it is easy to assemble, so it is used as beam-split. component of the imaging spectrometer. In addition, the real imaging spectrometer was tested for spectral resolution and distortion. The result demonstrates that the system has good ability in distortion control, and spectral resolution is 2 nm. These data satisfy the design requirement, and obtained spectrum of deuterium lamp through calibrated system are ideal results.
NASA Astrophysics Data System (ADS)
Cheaito, Ramez; Polanco, Carlos A.; Addamane, Sadhvikas; Zhang, Jingjie; Ghosh, Avik W.; Balakrishnan, Ganesh; Hopkins, Patrick E.
2018-02-01
We report on the room temperature thermal conductivity of AlAs-GaAs superlattices (SLs), in which we systematically vary the period thickness and total thickness between 2 -24 nm and 20.1 -2 ,160 nm , respectively. The thermal conductivity increases with the SL thickness and plateaus at a thickness around 200 nm, showing a clear transition from a quasiballistic to a diffusive phonon transport regime. These results demonstrate the existence of classical size effects in SLs, even at the highest interface density samples. We use harmonic atomistic Green's function calculations to capture incoherence in phonon transport by averaging the calculated transmission over several purely coherent simulations of independent SL with different random mixing at the AlAs-GaAs interfaces. These simulations demonstrate the significant contribution of incoherent phonon transport through the decrease in the transmission and conductance in the SLs as the number of interfaces increases. In spite of this conductance decrease, our simulations show a quasilinear increase in thermal conductivity with the superlattice thickness. This suggests that the observation of a quasilinear increase in thermal conductivity can have important contributions from incoherent phonon transport. Furthermore, this seemingly linear slope in thermal conductivity versus SL thickness data may actually be nonlinear when extended to a larger number of periods, which is a signature of incoherent effects. Indeed, this trend for superlattices with interatomic mixing at the interfaces could easily be interpreted as linear when the number of periods is small. Our results reveal that the change in thermal conductivity with period thickness is dominated by incoherent (particlelike) phonons, whose properties are not dictated by changes in the AlAs or GaAs phonon dispersion relations. This work demonstrates the importance of studying both period and sample thickness dependencies of thermal conductivity to understand the relative contributions of coherent and incoherent phonon transport in the thermal conductivity in SLs.
Biological growth in bodies with incoherent interfaces
NASA Astrophysics Data System (ADS)
Swain, Digendranath; Gupta, Anurag
2018-01-01
A general theory of thermodynamically consistent biomechanical-biochemical growth in a body, considering mass addition in the bulk and at an incoherent interface, is developed. The incoherency arises due to incompatibility of growth and elastic distortion tensors at the interface. The incoherent interface therefore acts as an additional source of internal stress besides allowing for rich growth kinematics. All the biochemicals in the model are essentially represented in terms of nutrient concentration fields, in the bulk and at the interface. A nutrient balance law is postulated which, combined with mechanical balances and kinetic laws, yields an initial-boundary-value problem coupling the evolution of bulk and interfacial growth, on the one hand, and the evolution of growth and nutrient concentration on the other. The problem is solved, and discussed in detail, for two distinct examples: annual ring formation during tree growth and healing of cutaneous wounds in animals.
Hetmańczyk, Joanna; Hetmańczyk, Lukasz; Migdał-Mikuli, Anna; Mikuli, Edward; Florek-Wojciechowska, Małgorzata; Harańczyk, Hubert
2014-04-24
Vibrational-reorientational dynamics of H2O ligands in the high- and low-temperature phases of [Sr(H2O)6]Cl2 was investigated by Raman Spectroscopy (RS), proton magnetic resonance ((1)H NMR), quasielastic and inelastic incoherent Neutron Scattering (QENS and IINS) methods. Neutron powder diffraction (NPD) measurements, performed simultaneously with QENS, did not indicated a change of the crystal structure at the phase transition (detected earlier by differential scanning calorimetry (DSC) at TC(h)=252.9 K (on heating) and at TC(c)=226.5K (on cooling)). Temperature dependence of the full-width at half-maximum (FWHM) of νs(OH) band at ca. 3248 cm(-1) in the RS spectra indicated small discontinuity in the vicinity of phase transition temperature, what suggests that the observed phase transition may be associated with a change of the H2O reorientational dynamics. However, an activation energy value (Ea) for the reorientational motions of H2O ligands in both phases is nearly the same and equals to ca. 8 kJ mol(-1). The QENS peaks, registered for low temperature phase do not show any broadening. However, in the high temperature phase a small QENS broadening is clearly visible, what implies that the reorientational dynamics of H2O ligands undergoes a change at the phase transition. (1)H NMR line is a superposition of two powder Pake doublets, differentiated by a dipolar broadening, suggesting that there are two types of the water molecules in the crystal lattice of [Sr(H2O)6]Cl2 which are structurally not equivalent average distances between the interacting protons are: 1.39 and 1.18 Å. However, their reorientational dynamics is very similar (τc=3.3⋅10(-10) s). Activation energies for the reorientational motion of these both kinds of H2O ligands have nearly the same values in an experimental error limit: and equal to ca. 40 kJ mole(-1). The phase transition is not seen in the (1)H NMR spectra temperature dependencies. Infrared (IR), Raman (RS) and inelastic incoherent neutron scattering (IINS) spectra were calculated by the DFT method and quite a good agreement with the experimental data was obtained. Copyright © 2014 Elsevier B.V. All rights reserved.
1981-03-01
m u z r- Z > H < m ff -< C 2 C) 2 3 r- c is o 1 L_ • o > • en • • • Ŕ O > 00 o 30 n 30 T r- 1> - n o > IDE N T S E LIN E D IT...responsibilities to the Defense Intelligence Agency ( DIA ), the Services, and the unified and specified commands for carrying out that guidance. 3 - JCS...Testing 1-2 1.4 JINTACCS Message Text Eorinats (MTF) and TADIL Messages 1-2 1.4.1 JINTACCS Message Text Formats (MTF) 1- 3 1.4.2 Developmental TADIL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Madanipour, Khosro; Tavassoly, Mohammad T
2009-02-01
We show theoretically and verify experimentally that the modulation transfer function (MTF) of a printing system can be determined by measuring the autocorrelation of a printed Ronchi grating. In practice, two similar Ronchi gratings are printed on two transparencies and the transparencies are superimposed with parallel grating lines. Then, the gratings are uniformly illuminated and the transmitted light from a large section is measured versus the displacement of one grating with respect to the other in a grating pitch interval. This measurement provides the required autocorrelation function for determination of the MTF.
Effect of aberrations in human eye on contrast sensitivity function
NASA Astrophysics Data System (ADS)
Quan, Wei; Wang, Feng-lin; Wang, Zhao-qi
2011-06-01
The quantitative analysis of the effect of aberrations in human eye on vision has important clinical value in the correction of aberrations. The wave-front aberrations of human eyes were measured with the Hartmann-Shack wave-front sensor and modulation transfer function (MTF) was computed from the wave-front aberrations. Contrast sensitivity function (CSF) was obtained from MTF and the retinal aerial image modulation (AIM). It is shown that the 2nd, 3rd, 4th, 5th, 6th Zernike aberrations deteriorate contrast sensitivity function. When the 2nd, 3rd, 4th, 5th, 6th Zernike aberrations are corrected high contrast sensitivity function can be obtained.
NASA Astrophysics Data System (ADS)
Intrator, T.; Zhang, S. Y.; Degnan, J. H.; Furno, I.; Grabowski, C.; Hsu, S. C.; Ruden, E. L.; Sanchez, P. G.; Taccetti, J. M.; Tuszewski, M.; Waganaar, W. J.; Wurden, G. A.
2004-05-01
Magnetized target fusion (MTF) is a potentially low cost path to fusion, intermediate in plasma regime between magnetic and inertial fusion energy. It requires compression of a magnetized target plasma and consequent heating to fusion relevant conditions inside a converging flux conserver. To demonstrate the physics basis for MTF, a field reversed configuration (FRC) target plasma has been chosen that will ultimately be compressed within an imploding metal liner. The required FRC will need large density, and this regime is being explored by the FRX-L (FRC-Liner) experiment. All theta pinch formed FRCs have some shock heating during formation, but FRX-L depends further on large ohmic heating from magnetic flux annihilation to heat the high density (2-5×1022m-3), plasma to a temperature of Te+Ti≈500 eV. At the field null, anomalous resistivity is typically invoked to characterize the resistive like flux dissipation process. The first resistivity estimate for a high density collisional FRC is shown here. The flux dissipation process is both a key issue for MTF and an important underlying physics question.
A distance-driven deconvolution method for CT image-resolution improvement
NASA Astrophysics Data System (ADS)
Han, Seokmin; Choi, Kihwan; Yoo, Sang Wook; Yi, Jonghyon
2016-12-01
The purpose of this research is to achieve high spatial resolution in CT (computed tomography) images without hardware modification. The main idea is to consider geometry optics model, which can provide the approximate blurring PSF (point spread function) kernel, which varies according to the distance from the X-ray tube to each point. The FOV (field of view) is divided into several band regions based on the distance from the X-ray source, and each region is deconvolved with a different deconvolution kernel. As the number of subbands increases, the overshoot of the MTF (modulation transfer function) curve increases first. After that, the overshoot begins to decrease while still showing a larger MTF than the normal FBP (filtered backprojection). The case of five subbands seems to show balanced performance between MTF boost and overshoot minimization. It can be seen that, as the number of subbands increases, the noise (STD) can be seen to show a tendency to decrease. The results shows that spatial resolution in CT images can be improved without using high-resolution detectors or focal spot wobbling. The proposed algorithm shows promising results in improving spatial resolution while avoiding excessive noise boost.
Lower bound for LCD image quality
NASA Astrophysics Data System (ADS)
Olson, William P.; Balram, Nikhil
1996-03-01
The paper presents an objective lower bound for the discrimination of patterns and fine detail in images on a monochrome LCD. In applications such as medical imaging and military avionics the information of interest is often at the highest frequencies in the image. Since LCDs are sampled data systems, their output modulation is dependent on the phase between the input signal and the sampling points. This phase dependence becomes particularly significant at high spatial frequencies. In order to use an LCD for applications such as those mentioned above it is essential to have a lower (worst case) bound on the performance of the display. We address this problem by providing a mathematical model for the worst case output modulation of an LCD in response to a sine wave input. This function can be interpreted as a worst case modulation transfer function (MTF). The intersection of the worst case MTF with the contrast threshold function (CTF) of the human visual system defines the highest spatial frequency that will always be detectable. In addition to providing the worst case limiting resolution, this MTF is combined with the CTF to produce objective worst case image quality values using the modulation transfer function area (MTFA) metric.
Zahorik, Pavel; Kim, Duck O; Kuwada, Shigeyuki; Anderson, Paul W; Brandewie, Eugene; Collecchia, Regina; Srinivasan, Nirmal
2012-06-01
Previous work [Zahorik et al., POMA, 12, 050005 (2011)] has reported that for a broadband noise carrier signal in a simulated reverberant sound field, human sensitivity to amplitude modulation (AM) is higher than would be predicted based on the broadband acoustical modulation transfer function (MTF) of the listening environment. Interpretation of this result was complicated by the fact that acoustical MTFs of rooms are often quite different for different carrier frequency regions, and listeners may have selectively responded to advantageous carrier frequency regions where the effective acoustic modulation loss due to the room was less than indicated by a broadband acoustic MTF analysis. Here, AM sensitivity testing and acoustic MTF analyses were expanded to include narrowband noise carriers (1-octave and 1/3-octave bands centered at 4 kHz), as well as monaural and binaural listening conditions. Narrowband results were found to be consistent with broadband results: In a reverberant sound field, human AM sensitivity is higher than indicated by the acoustical MTFs. The effect was greatest for modulation frequencies above 32 Hz and was present whether the stimulation was monaural or binaural. These results are suggestive of mechanisms that functionally enhance modulation in reverberant listening.
Structural Connectivity Networks of Transgender People
Hahn, Andreas; Kranz, Georg S.; Küblböck, Martin; Kaufmann, Ulrike; Ganger, Sebastian; Hummer, Allan; Seiger, Rene; Spies, Marie; Winkler, Dietmar; Kasper, Siegfried; Windischberger, Christian; Swaab, Dick F.; Lanzenberger, Rupert
2015-01-01
Although previous investigations of transsexual people have focused on regional brain alterations, evaluations on a network level, especially those structural in nature, are largely missing. Therefore, we investigated the structural connectome of 23 female-to-male (FtM) and 21 male-to-female (MtF) transgender patients before hormone therapy as compared with 25 female and 25 male healthy controls. Graph theoretical analysis of whole-brain probabilistic tractography networks (adjusted for differences in intracranial volume) showed decreased hemispheric connectivity ratios of subcortical/limbic areas for both transgender groups. Subsequent analysis revealed that this finding was driven by increased interhemispheric lobar connectivity weights (LCWs) in MtF transsexuals and decreased intrahemispheric LCWs in FtM patients. This was further reflected on a regional level, where the MtF group showed mostly increased local efficiencies and FtM patients decreased values. Importantly, these parameters separated each patient group from the remaining subjects for the majority of significant findings. This work complements previously established regional alterations with important findings of structural connectivity. Specifically, our data suggest that network parameters may reflect unique characteristics of transgender patients, whereas local physiological aspects have been shown to represent the transition from the biological sex to the actual gender identity. PMID:25217469
Andrasik, Michele Peake; Yoon, Ro; Mooney, Jessica; Broder, Gail; Bolton, Marcus; Votto, Teress; Davis-Vogel, Annet
2014-06-01
Observed seroincidence and prevalence rates in male-to-female (MTF) transgender individuals highlight the need for effective targeted HIV prevention strategies for this community. In order to develop an effective vaccine that can be used by transgender women, researchers must understand and address existing structural issues that present barriers to this group's participation in HIV vaccine clinical trials. Overcoming barriers to participation is important for ensuring HIV vaccine acceptability and efficacy for the MTF transgender community. To explore barriers and facilitators to MTF transgender participation in preventive HIV vaccine clinical trials, the HIV Vaccine Trials Network conducted focus groups among transgender women in four urban areas (Atlanta, Boston, Philadelphia, and San Francisco). Barriers and facilitators to engagement of transgender women in preventive HIV vaccine clinical trials led to the following recommendations: (a) transgender cultural competency training, (b) creating trans-friendly environments, (c) true partnerships with local trans-friendly organizations and health care providers, (d) protocols that focus on transgender specific issues, and (e) data collection and tracking of transgender individuals. These results have implications for the conduct of HIV vaccine trials, as well as engagement of transgender women in research programs in general.
A Review of the Status of Brain Structure Research in Transsexualism.
Guillamon, Antonio; Junque, Carme; Gómez-Gil, Esther
2016-10-01
The present review focuses on the brain structure of male-to-female (MtF) and female-to-male (FtM) homosexual transsexuals before and after cross-sex hormone treatment as shown by in vivo neuroimaging techniques. Cortical thickness and diffusion tensor imaging studies suggest that the brain of MtFs presents complex mixtures of masculine, feminine, and demasculinized regions, while FtMs show feminine, masculine, and defeminized regions. Consequently, the specific brain phenotypes proposed for MtFs and FtMs differ from those of both heterosexual males and females. These phenotypes have theoretical implications for brain intersexuality, asymmetry, and body perception in transsexuals as well as for Blanchard's hypothesis on sexual orientation in homosexual MtFs. Falling within the aegis of the neurohormonal theory of sex differences, we hypothesize that cortical differences between homosexual MtFs and FtMs and male and female controls are due to differently timed cortical thinning in different regions for each group. Cross-sex hormone studies have reported marked effects of the treatment on MtF and FtM brains. Their results are used to discuss the early postmortem histological studies of the MtF brain.
Transgender Surgery in Denmark From 1994 to 2015: 20-Year Follow-Up Study.
Aydin, Dogu; Buk, Liv Johanne; Partoft, Søren; Bonde, Christian; Thomsen, Michael Vestergaard; Tos, Tina
2016-04-01
Gender dysphoria is a mismatch between a person's biological sex and gender identity. The best treatment is believed to be hormonal therapy and gender-confirming surgery that will transition the individual toward the desired gender. Treatment in Denmark is covered by public health care, and gender-confirming surgery in Denmark is centralized at a single-center with few specialized plastic surgeons conducting top surgery (mastectomy or breast augmentation) and bottom surgery (vaginoplasty or phalloplasty and metoidioplasty). To report the first nationwide single-center review on transsexual patients in Denmark undergoing gender-confirming surgery performed by a single surgical team and to assess whether age at time of gender-confirming surgery decreased during a 20-year period. Electronic patient databases were used to identify patients diagnosed with gender identity disorders from January 1994 through March 2015. Patients were excluded from the study if they were pseudohermaphrodites or if their gender was not reported. Gender distribution, age trends, and surgeries performed for Danish patients who underwent gender-confirming surgery. One hundred fifty-eight patients referred for gender-confirming surgery were included. Fifty-five cases (35%) were male-to-female (MtF) and 103 (65%) were female-to-male (FtM). In total, 126 gender-confirming surgeries were performed. For FtM cases, top surgery (mastectomy) was conducted in 62 patients and bottom surgery (phalloplasty and metoidioplasty) was conducted in 17 patients. For MtF cases, 45 underwent bottom surgery (vaginoplasty), 2 of whom received breast augmentation. The FtM:MtF ratio of the referred patients was 1.9:1. The median age at the time of surgery decreased from 40 to 27 years during the 20-year period. Gender-confirming surgery was performed on 65 FtM and 40 MtF cases at our hospital, and 21 transsexuals underwent surgery abroad. Mastectomy was performed in 62 FtM and bottom surgery in 17 FtM cases. Vaginoplasty was performed in 45 MtF and breast augmentation in 2 MtF cases. There was a significant decrease in age at the time of gender-confirming surgery during the course of the study period. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Bencomo, Jose Antonio Fagundez
The main goal of this study was to relate physical changes in image quality measured by Modulation Transfer Function (MTF) to diagnostic accuracy. One Hundred and Fifty Kodak Min-R screen/film combination conventional craniocaudal mammograms obtained with the Pfizer Microfocus Mammographic system were selected from the files of the Department of Radiology, at M.D. Anderson Hospital and Tumor Institute. The mammograms included 88 cases with a variety of benign diagnosis and 62 cases with a variety of malignant biopsy diagnosis. The average age of the patient population was 55 years old. 70 cases presented calcifications with 30 cases having calcifications smaller than 0.5mm. 46 cases presented irregular bordered masses larger than 1 cm. 30 cases presented smooth bordered masses with 20 larger than 1 cm. Four separated copies of the original images were made each having a different change in the MTF using a defocusing technique whereby copies of the original were obtained by light exposure through different thicknesses (spacing) of transparent film base. The mammograms were randomized, and evaluated by three experienced mammographers for the degree of visibility of various anatomical breast structures and pathological lesions (masses and calicifications), subjective image quality, and mammographic interpretation. 3,000 separate evaluations were anayzed by several statistical techniques including Receiver Operating Characteristic curve analysis, McNemar test for differences between proportions and the Landis et al. method of agreement weighted kappa for ordinal categorical data. Results from the statistical analysis show: (1) There were no statistical significant differences in the diagnostic accuracy of the observers when diagnosing from mammograms with the same MTF. (2) There were no statistically significant differences in diagnostic accuracy for each observer when diagnosing from mammograms with the different MTF's used in the study. (3) There statistical significant differences in detail visibility between the copies and the originals. Detail visibility was better in the originals. (4) Feature interpretations were not significantly different between the originals and the copies. (5) Perception of image quality did not affect image interpretation. Continuation and improvement of this research ca be accomplished by: using a case population more sensitive to MTF changes, i.e., asymptomatic women with minimum breast cancer, more observers (including less experienced radiologists and experienced technologists) must collaborate in the study, and using a minimum of 200 benign and 200 malignant cases.
Aoun, Bachir; Pellegrini, Eric; Trapp, Marcus; Natali, Francesca; Cantù, Laura; Brocca, Paola; Gerelli, Yuri; Demé, Bruno; Marek Koza, Michael; Johnson, Mark; Peters, Judith
2016-04-01
Neutron scattering techniques have been employed to investigate 1,2-dimyristoyl-sn -glycero-3-phosphocholine (DMPC) membranes in the form of multilamellar vesicles (MLVs) and deposited, stacked multilamellar-bilayers (MLBs), covering transitions from the gel to the liquid phase. Neutron diffraction was used to characterise the samples in terms of transition temperatures, whereas elastic incoherent neutron scattering (EINS) demonstrates that the dynamics on the sub-macromolecular length-scale and pico- to nano-second time-scale are correlated with the structural transitions through a discontinuity in the observed elastic intensities and the derived mean square displacements. Molecular dynamics simulations have been performed in parallel focussing on the length-, time- and temperature-scales of the neutron experiments. They correctly reproduce the structural features of the main gel-liquid phase transition. Particular emphasis is placed on the dynamical amplitudes derived from experiment and simulations. Two methods are used to analyse the experimental data and mean square displacements. They agree within a factor of 2 irrespective of the probed time-scale, i.e. the instrument utilized. Mean square displacements computed from simulations show a comparable level of agreement with the experimental values, albeit, the best match with the two methods varies for the two instruments. Consequently, experiments and simulations together give a consistent picture of the structural and dynamical aspects of the main lipid transition and provide a basis for future, theoretical modelling of dynamics and phase behaviour in membranes. The need for more detailed analytical models is pointed out by the remaining variation of the dynamical amplitudes derived in two different ways from experiments on the one hand and simulations on the other.
NASA Astrophysics Data System (ADS)
Kogure, Toshihiro; Raimbourg, Hugues; Kumamoto, Akihito; Fujii, Eiko; Ikuhara, Yuichi
2014-12-01
High-resolution structure analyses using electron beam techniques have been performed for the investigation of subgrain boundaries (SGBs) in deformed orthopyroxene (Opx) in mylonite from Hidaka Metamorphic Belt, Hokkaido, Japan, to understand ductile deformation mechanism of silicate minerals in shear zones. Scanning electron microscopy (SEM) and electron backscatter diffraction (EBSD) analysis of Opx porphyroclasts in the mylonitic rock indicated that the crystal orientation inside the Opx crystals gradually changes by rotation about the b-axis by SGBs and crystal folding. In order to observe the SGBs along the b-axis by transmission electron microscopy (TEM) or scanning TEM (STEM), the following sample preparation protocol was adopted. First, petrographic thin sections were slightly etched with hydrofluoric acid to identify SGBs in SEM. The Opx crystals whose b-axes were oriented close to the normal of the surface were identified by EBSD, and the areas containing SGBs were picked and thinned for (S) TEM analysis with a focused ion beam instrument with micro-sampling system. High-resolution TEM imaging of the SGBs in Opx revealed various boundary structures from a periodic array of dissociated (100) [001] edge dislocations to partially or completely incoherent crystals, depending on the misorientation angle. Atomic-resolution STEM imaging clearly confirmed the formation of clinopyroxene (Cpx) structure between the dissociated partial dislocations. Moreover, X-ray microanalysis in STEM revealed that the Cpx contains a considerable amount of calcium replacing iron. Such chemical inhomogeneity may limit glide motion of the dislocation and eventually the plastic deformation of the Opx porphyroclasts at a low temperature. Chemical profiles across the high-angle incoherent SGB also showed an enrichment of the latter in calcium at the boundary, suggesting that SGBs are an efficient diffusion pathway of calcium out of host Opx grain during cooling.
Is phase measurement necessary for incoherent holographic 3D imaging?
NASA Astrophysics Data System (ADS)
Rosen, Joseph; Vijayakumar, A.; Rai, Mani Ratnam; Mukherjee, Saswata
2018-02-01
Incoherent digital holography can be used for several applications, among which are high resolution fluorescence microscopy and imaging through a scattering medium. Historically, an incoherent digital hologram has been usually recorded by self-interference systems in which both interfering beams are originated from the same observed object. The self-interference system enables to read the phase distribution of the wavefronts propagating from an object and consequently to decode the 3D location of the object points. In this presentation, we survey several cases in which 3D holographic imaging can be done without the phase information and without two-wave interference.
NASA Astrophysics Data System (ADS)
Rybalova, Elena; Semenova, Nadezhda; Strelkova, Galina; Anishchenko, Vadim
2017-06-01
We study the transition from coherence (complete synchronization) to incoherence (spatio-temporal chaos) in ensembles of nonlocally coupled chaotic maps with nonhyperbolic and hyperbolic attractors. As basic models of a partial element we use the Henon map and the Lozi map. We show that the transition to incoherence in a ring of coupled Henon maps occurs through the appearance of phase and amplitude chimera states. An ensemble of coupled Lozi maps demonstrates the coherence-incoherence transition via solitary states and no chimera states are observed in this case.
NASA Astrophysics Data System (ADS)
Lachinova, Svetlana L.; Vorontsov, Mikhail A.; Filimonov, Grigory A.; LeMaster, Daniel A.; Trippel, Matthew E.
2017-07-01
Computational efficiency and accuracy of wave-optics-based Monte-Carlo and brightness function numerical simulation techniques for incoherent imaging of extended objects through atmospheric turbulence are evaluated. Simulation results are compared with theoretical estimates based on known analytical solutions for the modulation transfer function of an imaging system and the long-exposure image of a Gaussian-shaped incoherent light source. It is shown that the accuracy of both techniques is comparable over the wide range of path lengths and atmospheric turbulence conditions, whereas the brightness function technique is advantageous in terms of the computational speed.
Comparison of Te and Ti from Ogo 6 and from various incoherent scatter radars.
NASA Technical Reports Server (NTRS)
Mcclure, J. P.; Hanson, W. B.; Nagy, A. F.; Cicerone, R. J.; Brace, L. H.; Baron, M.; Bauer, P.; Carlson, H. C.; Evans, J. V.; Taylor, G. N.
1973-01-01
Langmuir probe and retarding potential analyzer (RPA) data on the electron and ion temperatures Te and Ti obtained from Ogo 6 are compared with Te and Ti values obtained from the incoherent scatter network. The satellite to radar temperature ratio TeS/TeR is 1.15 on the average for these comparisons. This discrepancy is larger than the uncertainties usually placed on the probe and radar Te values. The ion temperature ratio TiS/TiR approximately 1.0, independent of the particular radar examined. This comparison serves as an intercalibration of the incoherent scatter network.
NASA Astrophysics Data System (ADS)
Zhao, Shun-Cai; Guo, Hong-Wei; Wei, Xiao-Jing
2017-10-01
The left-handedness was demonstrated by the simulation with a three-level quantum system in an Er3+ -dopped ZrF4-BaF2-LaF3- AlF3-NaF (ZBLAFN) optical fiber. And the left-handedness can be regulated by the incoherent pumping field. Our scheme may provide a solid candidate other than the coherent atomic vapor for left-handedness, and may extend the application of the rare-earth-ion-doped optical fiber in metamaterials and of the incoherent pumping light field in quantum optics.
NASA Astrophysics Data System (ADS)
Fiedler, A.; Schewski, R.; Baldini, M.; Galazka, Z.; Wagner, G.; Albrecht, M.; Irmscher, K.
2017-10-01
We present a quantitative model that addresses the influence of incoherent twin boundaries on the electrical properties in β-Ga2O3. This model can explain the mobility collapse below a threshold electron concentration of 1 × 1018 cm-3 as well as partly the low doping efficiency in β-Ga2O3 layers grown homoepitaxially by metal-organic vapor phase epitaxy on (100) substrates of only slight off-orientation. A structural analysis by transmission electron microscopy (TEM) reveals a high density of twin lamellae in these layers. In contrast to the coherent twin boundaries parallel to the (100) plane, the lateral incoherent twin boundaries exhibit one dangling bond per unit cell that acts as an acceptor-like electron trap. Since the twin lamellae are thin, we consider the incoherent twin boundaries to be line defects with a density of 1011-1012 cm-2 as determined by TEM. We estimate the influence of the incoherent twin boundaries on the electrical transport properties by adapting Read's model of charged dislocations. Our calculations quantitatively confirm that the mobility reduction and collapse as well as partly the compensation are due to the presence of twin lamellae.
Coherent and incoherent ultrasound backscatter from cell aggregates.
de Monchy, Romain; Destrempes, François; Saha, Ratan K; Cloutier, Guy; Franceschini, Emilie
2016-09-01
The effective medium theory (EMT) was recently developed to model the ultrasound backscatter from aggregating red blood cells [Franceschini, Metzger, and Cloutier, IEEE Trans. Ultrason. Ferroelectr. Freq. Control 58, 2668-2679 (2011)]. The EMT assumes that aggregates can be treated as homogeneous effective scatterers, which have effective properties determined by the aggregate compactness and the acoustical characteristics of the cells and the surrounding medium. In this study, the EMT is further developed to decompose the differential backscattering cross section of a single cell aggregate into coherent and incoherent components. The coherent component corresponds to the squared norm of the average scattering amplitude from the effective scatterer, and the incoherent component considers the variance of the scattering amplitude (i.e., the mean squared norm of the fluctuation of the scattering amplitude around its mean) within the effective scatterer. A theoretical expression for the incoherent component based on the structure factor is proposed and compared with another formulation based on the Gaussian direct correlation function. This theoretical improvement is assessed using computer simulations of ultrasound backscatter from aggregating cells. The consideration of the incoherent component based on the structure factor allows us to approximate the simulations satisfactorily for a product of the wavenumber times the aggregate radius kr ag around 2.
Liu, Chang; Xue, Zhimin; Palaniyappan, Lena; Zhou, Li; Liu, Haihong; Qi, Chang; Wu, Guowei; Mwansisya, Tumbwene E; Tao, Haojuan; Chen, Xudong; Huang, Xiaojun; Liu, Zhening; Pu, Weidan
2016-03-01
Several resting-state neuroimaging studies in schizophrenia indicate an excessive brain activity while others report an incoherent brain activity at rest. No direct evidence for the simultaneous presence of both excessive and incoherent brain activity has been established to date. Moreover, it is unclear whether unaffected siblings of schizophrenia patients who share half of the affected patient's genotype also exhibit the excessive and incoherent brain activity that may render them vulnerable to the development of schizophrenia. 27 pairs of schizophrenia patients and their unaffected siblings, as well as 27 healthy controls, were scanned using gradient-echo echo-planar imaging at rest. By using amplitude of low-frequency fluctuations (ALFF) and regional homogeneity (Reho), we investigated the intensity and synchronization of local spontaneous neuronal activity in three groups. We observed that increased amplitude and reduced synchronization (coherence) of spontaneous neuronal activity were shared by patients and their unaffected siblings. The key brain regions with this abnormal neural pattern in both patients and siblings included the middle temporal, orbito-frontal, inferior occipital and fronto-insular gyrus. This abnormal neural pattern of excessive and incoherent neuronal activity shared by schizophrenia patients and their healthy siblings may improve our understanding of neuropathology and genetic predisposition in schizophrenia. Copyright © 2016 Elsevier B.V. All rights reserved.
Intra-ocular lens optical changes resulting from the loading of dexamethasone.
Artigas, José M; García-Domene, M Carmen; Navea, Amparo; Botella, Pablo; Fernández, Eduardo
2017-10-01
To study the optical changes on hydrogel-silicone intraocular lenses (IOLs) resulting from loading them with dexamethasone. We used prototype hydrogel(pHEMA)-silicone IOLs and loaded the matrices with an anti-inflammatory drug (dexamethasone). The optical properties we analyzed experimentally were a) modulation transfer function (MTF); b) spectral transmission; c) diopter power. These determinations were performed on drug-loaded IOLs, IOLs that had released the drug, and IOLs that had not been drug-loaded. Loading a hydrogel-silicone IOL with dexamethasone results in impairment of its optical qualities, in particular its MTF and spectral transmission, but not dioptric power. However, once the drug has been released, it almost recovers its initial optical properties.
Intra-ocular lens optical changes resulting from the loading of dexamethasone
Artigas, José M.; García-Domene, M. Carmen; Navea, Amparo; Botella, Pablo; Fernández, Eduardo
2017-01-01
To study the optical changes on hydrogel-silicone intraocular lenses (IOLs) resulting from loading them with dexamethasone. We used prototype hydrogel(pHEMA)-silicone IOLs and loaded the matrices with an anti-inflammatory drug (dexamethasone). The optical properties we analyzed experimentally were a) modulation transfer function (MTF); b) spectral transmission; c) diopter power. These determinations were performed on drug-loaded IOLs, IOLs that had released the drug, and IOLs that had not been drug-loaded. Loading a hydrogel-silicone IOL with dexamethasone results in impairment of its optical qualities, in particular its MTF and spectral transmission, but not dioptric power. However, once the drug has been released, it almost recovers its initial optical properties. PMID:29082089
Minimum resolvable power contrast model
NASA Astrophysics Data System (ADS)
Qian, Shuai; Wang, Xia; Zhou, Jingjing
2018-01-01
Signal-to-noise ratio and MTF are important indexs to evaluate the performance of optical systems. However,whether they are used alone or joint assessment cannot intuitively describe the overall performance of the system. Therefore, an index is proposed to reflect the comprehensive system performance-Minimum Resolvable Radiation Performance Contrast (MRP) model. MRP is an evaluation model without human eyes. It starts from the radiance of the target and the background, transforms the target and background into the equivalent strips,and considers attenuation of the atmosphere, the optical imaging system, and the detector. Combining with the signal-to-noise ratio and the MTF, the Minimum Resolvable Radiation Performance Contrast is obtained. Finally the detection probability model of MRP is given.
Space Imagery Enhancement Investigations; Software for Processing Middle Atmosphere Data
2011-12-19
SUPPLEMENTARY NOTES 14. ABSTRACT This report summarizes work related to optical superresolution for the ideal incoherent 1D spread function...optical superresolution , incoherent image eigensystem, image registration, multi-frame image reconstruction, deconvolution 16. SECURITY... Superresolution -Related Investigations ............................................................................. 1 2.2.1 Eigensystem Formulations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dorrer, C.; Consentino, A.; Irwin, D.
Characterizing the prepulse temporal contrast of optical pulses is required to understand their interaction with matter. Light with relatively low intensity can interact with the target before the main high-intensity pulse. Estimating the intensity contrast, instead of the spatially averaged power contrast, is important to understand intensity-dependent laser–matter interactions. A direct optical approach to determining the on-shot intensity of the incoherent pedestal on an aberrated high-intensity laser system is presented. The spatially resolved focal spot of the incoherent pedestal preceding the main coherent pulse and the intensity contrast are calculated using experimental data. Furthermore, this technique is experimentally validated onmore » one of the chirped pulse amplification beamlines of the OMEGA EP Laser System. The intensity contrast of a 1-kJ, 10-ps laser pulse is shown to be ~10× higher than the power contrast because of the larger spatial extent of the incoherent focal spot relative to the coherent focal spot.« less
A Comparison of seismic instrument noise coherence analysis techniques
Ringler, A.T.; Hutt, C.R.; Evans, J.R.; Sandoval, L.D.
2011-01-01
The self-noise of a seismic instrument is a fundamental characteristic used to evaluate the quality of the instrument. It is important to be able to measure this self-noise robustly, to understand how differences among test configurations affect the tests, and to understand how different processing techniques and isolation methods (from nonseismic sources) can contribute to differences in results. We compare two popular coherence methods used for calculating incoherent noise, which is widely used as an estimate of instrument self-noise (incoherent noise and self-noise are not strictly identical but in observatory practice are approximately equivalent; Holcomb, 1989; Sleeman et al., 2006). Beyond directly comparing these two coherence methods on similar models of seismometers, we compare how small changes in test conditions can contribute to incoherent-noise estimates. These conditions include timing errors, signal-to-noise ratio changes (ratios between background noise and instrument incoherent noise), relative sensor locations, misalignment errors, processing techniques, and different configurations of sensor types.
Dorrer, C.; Consentino, A.; Irwin, D.
2016-05-18
Characterizing the prepulse temporal contrast of optical pulses is required to understand their interaction with matter. Light with relatively low intensity can interact with the target before the main high-intensity pulse. Estimating the intensity contrast, instead of the spatially averaged power contrast, is important to understand intensity-dependent laser–matter interactions. A direct optical approach to determining the on-shot intensity of the incoherent pedestal on an aberrated high-intensity laser system is presented. The spatially resolved focal spot of the incoherent pedestal preceding the main coherent pulse and the intensity contrast are calculated using experimental data. Furthermore, this technique is experimentally validated onmore » one of the chirped pulse amplification beamlines of the OMEGA EP Laser System. The intensity contrast of a 1-kJ, 10-ps laser pulse is shown to be ~10× higher than the power contrast because of the larger spatial extent of the incoherent focal spot relative to the coherent focal spot.« less
Coherent transport and energy flow patterns in photosynthesis under incoherent excitation.
Pelzer, Kenley M; Can, Tankut; Gray, Stephen K; Morr, Dirk K; Engel, Gregory S
2014-03-13
Long-lived coherences have been observed in photosynthetic complexes after laser excitation, inspiring new theories regarding the extreme quantum efficiency of photosynthetic energy transfer. Whether coherent (ballistic) transport occurs in nature and whether it improves photosynthetic efficiency remain topics of debate. Here, we use a nonequilibrium Green's function analysis to model exciton transport after excitation from an incoherent source (as opposed to coherent laser excitation). We find that even with an incoherent source, the rate of environmental dephasing strongly affects exciton transport efficiency, suggesting that the relationship between dephasing and efficiency is not an artifact of coherent excitation. The Green's function analysis provides a clear view of both the pattern of excitonic fluxes among chromophores and the multidirectionality of energy transfer that is a feature of coherent transport. We see that even in the presence of an incoherent source, transport occurs by qualitatively different mechanisms as dephasing increases. Our approach can be generalized to complex synthetic systems and may provide a new tool for optimizing synthetic light harvesting materials.
NASA Technical Reports Server (NTRS)
Moebes, T. A.
1994-01-01
To locate the accessory pathway(s) in preexicitation syndromes, epicardial and endocardial ventricular mapping is performed during anterograde ventricular activation via accessory pathway(s) from data originally received in signal form. As the number of channels increases, it is pertinent that more automated detection of coherent/incoherent signals is achieved as well as the prediction and prognosis of ventricular tachywardia (VT). Today's computers and computer program algorithms are not good in simple perceptual tasks such as recognizing a pattern or identifying a sound. This discrepancy, among other things, has been a major motivating factor in developing brain-based, massively parallel computing architectures. Neural net paradigms have proven to be effective at pattern recognition tasks. In signal processing, the picking of coherent/incoherent signals represents a pattern recognition task for computer systems. The picking of signals representing the onset ot VT also represents such a computer task. We attacked this problem by defining four signal attributes for each potential first maximal arrival peak and one signal attribute over the entire signal as input to a back propagation neural network. One attribute was the predicted amplitude value after the maximum amplitude over a data window. Then, by using a set of known (user selected) coherent/incoherent signals, and signals representing the onset of VT, we trained the back propagation network to recognize coherent/incoherent signals, and signals indicating the onset of VT. Since our output scheme involves a true or false decision, and since the output unit computes values between 0 and 1, we used a Fuzzy Arithmetic approach to classify data as coherent/incoherent signals. Furthermore, a Mean-Square Error Analysis was used to determine system stability. The neural net based picking coherent/incoherent signal system achieved high accuracy on picking coherent/incoherent signals on different patients. The system also achieved a high accuracy of picking signals which represent the onset of VT, that is, VT immediately followed these signals. A special binary representation of the input and output data allowed the neural network to train very rapidly as compared to another standard decimal or normalized representations of the data.
Incoherent averaging of phase singularities in speckle-shearing interferometry.
Mantel, Klaus; Nercissian, Vanusch; Lindlein, Norbert
2014-08-01
Interferometric speckle techniques are plagued by the omnipresence of phase singularities, impairing the phase unwrapping process. To reduce the number of phase singularities by physical means, an incoherent averaging of multiple speckle fields may be applied. It turns out, however, that the results may strongly deviate from the expected √N behavior. Using speckle-shearing interferometry as an example, we investigate the mechanism behind the reduction of phase singularities, both by calculations and by computer simulations. Key to an understanding of the reduction mechanism during incoherent averaging is the representation of the physical averaging process in terms of certain vector fields associated with each speckle field.
Coherent and incoherent off-axis Hermite-Gaussian beam combinations.
Lü, B; Ma, H
2000-03-10
A detailed study of the coherent and the incoherent combinations of two-dimensional off-axis Hermite-Gaussian beams with rectangular symmetry is made. The closed-form propagation formulas of the resulting beam are derived, and the resulting beam quality in terms of the M(2) factor and power in the bucket is discussed and compared for the coherent and the incoherent combinations. In addition, it is shown that the resulting astigmatic beam can be symmetrized in the sense of the second-moment definition of beam width. However, the symmetrizing transformation of the resulting astigmatic beams is incomplete, because there exist different irradiance profiles.
Analysis of off-axis incoherent digital holographic microscopy
NASA Astrophysics Data System (ADS)
Quan, Xiangyu; Matoba, Osamu; Awatsuji, Yasuhiro
2017-05-01
Off-axis incoherent digital holography that enables single-shot three-dimensional (3D) distribution is introduced in the paper. Conventional fluorescence microscopy images 3D fields by sectioning, this prevents instant imaging of fast reactions of living cells. In order to realize digital holography from incoherent light, we adapted common path configuration to achieve the best temporal coherence. And by introducing gratings, we shifted the direction of each light to achieve off-axis interference. Simulations and preliminary experiments using LED light have confirmed the results. We expect to use this method to realize 3D phase imaging and fluorescent imaging at the same time from the same biological sample.
Compressive self-interference Fresnel digital holography with faithful reconstruction
NASA Astrophysics Data System (ADS)
Wan, Yuhong; Man, Tianlong; Han, Ying; Zhou, Hongqiang; Wang, Dayong
2017-05-01
We developed compressive self-interference digital holographic approach that allows retrieving three-dimensional information of the spatially incoherent objects from single-shot captured hologram. The Fresnel incoherent correlation holography is combined with parallel phase-shifting technique to instantaneously obtain spatial-multiplexed phase-shifting holograms. The recording scheme is regarded as compressive forward sensing model, thus the compressive-sensing-based reconstruction algorithm is implemented to reconstruct the original object from the under sampled demultiplexed sub-holograms. The concept was verified by simulations and experiments with simulating use of the polarizer array. The proposed technique has great potential to be applied in 3D tracking of spatially incoherent samples.
Ultrafast Dephasing and Incoherent Light Photon Echoes in Organic Amorphous Systems
NASA Astrophysics Data System (ADS)
Yano, Ryuzi; Matsumoto, Yoshinori; Tani, Toshiro; Nakatsuka, Hiroki
1989-10-01
Incoherent light photon echoes were observed in organic amorphous systems (cresyl violet in polyvinyl alcohol and 1,4-dihydroxyanthraquinone in polymethacrylic acid) by using temporally-incoherent nanosecond laser pulses. It was found that an echo decay curve of an organic amorphous system is composed of a sharp peak which decays very rapidly and a slowly decaying wing at the tail. We show that the persistent hole burning (PHB) spectra were reproduced by the Fourier-cosine transforms of the echo decay curves. We claim that in general, we must take into account the multi-level feature of the system in order to explain ultrafast dephasing at very low temperatures.
Using an incoherent target return to adaptively focus through atmospheric turbulence
NASA Astrophysics Data System (ADS)
Nelson, W.; Palastro, J. P.; Wu, C.; Davis, C. C.
2016-03-01
A laser beam propagating to a remote target through atmospheric turbulence acquires intensity fluctuations. If the target is cooperative and provides a coherent return beam, the phase measured near the beam transmitter and adaptive optics can, in principle, correct these fluctuations. Generally, however, the target is uncooperative. In this case, we show that an incoherent return from the target can be used instead. Using the principle of reciprocity, we derive a novel relation between the field at the target and the reflected field at a detector. We simulate an adaptive optics system that utilizes this relation to focus a beam through atmospheric turbulence onto the incoherent surface.
NASA Astrophysics Data System (ADS)
Seyyed, Hossein Asadpour; G, Solookinejad; M, Panahi; E Ahmadi, Sangachin
2016-03-01
Role of Fano interference and incoherent pumping field on optical bistability in a four-level designed InGaN/GaN quantum dot nanostructure embedded in a unidirectional ring cavity are analyzed. It is found that intensity threshold of optical bistability can be manipulated by Fano interference. It is shown that incoherent pumping fields make the threshold of optical bistability behave differently by Fano interference. Moreover, in the presence of Fano interference the medium becomes phase-dependent. Therefore, the relative phase of applied fields can affect the behaviors of optical bistability and intensity threshold can be controlled easily.
Optimal design of a high accuracy photoelectric auto-collimator based on position sensitive detector
NASA Astrophysics Data System (ADS)
Yan, Pei-pei; Yang, Yong-qing; She, Wen-ji; Liu, Kai; Jiang, Kai; Duan, Jing; Shan, Qiusha
2018-02-01
A kind of high accuracy Photo-electric auto-collimator based on PSD was designed. The integral structure composed of light source, optical lens group, Position Sensitive Detector (PSD) sensor, and its hardware and software processing system constituted. Telephoto objective optical type is chosen during the designing process, which effectively reduces the length, weight and volume of the optical system, as well as develops simulation-based design and analysis of the auto-collimator optical system. The technical indicators of auto-collimator presented by this paper are: measuring resolution less than 0.05″; a field of view is 2ω=0.4° × 0.4° measuring range is +/-5' error of whole range measurement is less than 0.2″. Measuring distance is 10m, which are applicable to minor-angle precise measuring environment. Aberration analysis indicates that the MTF close to the diffraction limit, the spot in the spot diagram is much smaller than the Airy disk. The total length of the telephoto lens is only 450mm by the design of the optical machine structure optimization. The autocollimator's dimension get compact obviously under the condition of the image quality is guaranteed.
A Physics Exploratory Experiment on Plasma Liner Formation
NASA Technical Reports Server (NTRS)
Thio, Y. C. Francis; Knapp, Charles E.; Kirkpatrick, Ronald C.; Siemon, Richard E.; Turchi, Peter
2002-01-01
Momentum flux for imploding a target plasma in magnetized target fusion (MTF) may be delivered by an array of plasma guns launching plasma jets that would merge to form an imploding plasma shell (liner). In this paper, we examine what would be a worthwhile experiment to do in order to explore the dynamics of merging plasma jets to form a plasma liner as a first step in establishing an experimental database for plasma-jets driven magnetized target fusion (PJETS-MTF). Using past experience in fusion energy research as a model, we envisage a four-phase program to advance the art of PJETS-MTF to fusion breakeven Q is approximately 1). The experiment (PLX (Plasma Liner Physics Exploratory Experiment)) described in this paper serves as Phase I of this four-phase program. The logic underlying the selection of the experimental parameters is presented. The experiment consists of using twelve plasma guns arranged in a circle, launching plasma jets towards the center of a vacuum chamber. The velocity of the plasma jets chosen is 200 km/s, and each jet is to carry a mass of 0.2 mg - 0.4 mg. A candidate plasma accelerator for launching these jets consists of a coaxial plasma gun of the Marshall type.
Native and engineered sensors for Ca2+ and Zn2+: lessons from calmodulin and MTF1.
Carpenter, Margaret C; Palmer, Amy E
2017-05-09
Ca 2+ and Zn 2+ dynamics have been identified as important drivers of physiological processes. In order for these dynamics to encode function, the cell must have sensors that transduce changes in metal concentration to specific downstream actions. Here we compare and contrast the native metal sensors: calmodulin (CaM), the quintessential Ca 2+ sensor and metal-responsive transcription factor 1 (MTF1), a candidate Zn 2+ sensor. While CaM recognizes and modulates the activity of hundreds of proteins through allosteric interactions, MTF1 recognizes a single DNA motif that is distributed throughout the genome regulating the transcription of many target genes. We examine how the different inorganic chemistries of these two metal ions may shape these different mechanisms transducing metal ion concentration into changing physiologic activity. In addition to native metal sensors, scientists have engineered sensors to spy on the dynamic changes of metals in cells. The inorganic chemistry of the metals shapes the possibilities in the design strategies of engineered sensors. We examine how different strategies to tune the affinities of engineered sensors mirror the strategies nature developed to sense both Ca 2+ and Zn 2+ in cells. © 2017 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.
Drivers and mechanisms of tree mortality in moist tropical forests.
McDowell, Nate; Allen, Craig D; Anderson-Teixeira, Kristina; Brando, Paulo; Brienen, Roel; Chambers, Jeff; Christoffersen, Brad; Davies, Stuart; Doughty, Chris; Duque, Alvaro; Espirito-Santo, Fernando; Fisher, Rosie; Fontes, Clarissa G; Galbraith, David; Goodsman, Devin; Grossiord, Charlotte; Hartmann, Henrik; Holm, Jennifer; Johnson, Daniel J; Kassim, Abd Rahman; Keller, Michael; Koven, Charlie; Kueppers, Lara; Kumagai, Tomo'omi; Malhi, Yadvinder; McMahon, Sean M; Mencuccini, Maurizio; Meir, Patrick; Moorcroft, Paul; Muller-Landau, Helene C; Phillips, Oliver L; Powell, Thomas; Sierra, Carlos A; Sperry, John; Warren, Jeff; Xu, Chonggang; Xu, Xiangtao
2018-02-16
Tree mortality rates appear to be increasing in moist tropical forests (MTFs) with significant carbon cycle consequences. Here, we review the state of knowledge regarding MTF tree mortality, create a conceptual framework with testable hypotheses regarding the drivers, mechanisms and interactions that may underlie increasing MTF mortality rates, and identify the next steps for improved understanding and reduced prediction. Increasing mortality rates are associated with rising temperature and vapor pressure deficit, liana abundance, drought, wind events, fire and, possibly, CO 2 fertilization-induced increases in stand thinning or acceleration of trees reaching larger, more vulnerable heights. The majority of these mortality drivers may kill trees in part through carbon starvation and hydraulic failure. The relative importance of each driver is unknown. High species diversity may buffer MTFs against large-scale mortality events, but recent and expected trends in mortality drivers give reason for concern regarding increasing mortality within MTFs. Models of tropical tree mortality are advancing the representation of hydraulics, carbon and demography, but require more empirical knowledge regarding the most common drivers and their subsequent mechanisms. We outline critical datasets and model developments required to test hypotheses regarding the underlying causes of increasing MTF mortality rates, and improve prediction of future mortality under climate change. No claim to original US government works New Phytologist © 2018 New Phytologist Trust.
Imaging characteristics of different mammographic screens.
Kuhn, H; Knüpfer, W
1992-01-01
A study of mammography systems with green-emitting screens was conducted to determine how the image quality parameters (apart from dose requirement), such as modulation transfer function (MTF) and Wiener spectrum (WS), depend on the dye content of the compound and coating weight of the screen. In addition, the contribution to total noise of the individual components, i.e., film, screen, and quantum noise, was studied. The quantities derived from MTF and WS, namely detective quantum efficiency (DQE) and noise equivalent quanta (NEQ), were also investigated in regard to their dose dependency. It can be demonstrated that the MTF of the screens becomes more favorable when the dye content is increased, while noise is not significantly affected. This suggests the use of a mammography screen capable of greater detail recognition, requiring at least double the dose of today's conventional systems with approximately 80 microGy system dose. On the other hand, the manufacture of a screen with about 60% of the dose of the conventional system is possible with very little loss in image quality. For the systems in common use today (80 microGy), quantum noise represents a considerable share of the total noise at low spatial frequencies, whereas in high spatial frequencies, the graininess of the film dominates quantum noise and screen structure.
NASA Astrophysics Data System (ADS)
Scaduto, L. C. N.; Carvalho, E. G.; Modugno, R. G.; Cartolano, R.; Evangelista, S. H.; Segoria, D.; Santos, A. G.; Stefani, M. A.; Castro Neto, J. C.
2017-11-01
The purpose of this paper is to present the optical system developed for the Wide Field imaging Camera - WFI that will be integrated to the CBERS 3 and 4 satellites (China Brazil Earth resources Satellite). This camera will be used for remote sensing of the Earth and it is aimed to work at an altitude of 778 km. The optical system is designed for four spectral bands covering the range of wavelengths from blue to near infrared and its field of view is +/-28.63°, which covers 866 km, with a ground resolution of 64 m at nadir. WFI has been developed through a consortium formed by Opto Electrônica S. A. and Equatorial Sistemas. In particular, we will present the optical analysis based on the Modulation Transfer Function (MTF) obtained during the Engineering Model phase (EM) and the optical tests performed to evaluate the requirements. Measurements of the optical system MTF have been performed using an interferometer at the wavelength of 632.8nm and global MTF tests (including the CCD and signal processing electronic) have been performed by using a collimator with a slit target. The obtained results showed that the performance of the optical system meets the requirements of project.
NASA Astrophysics Data System (ADS)
Nano, Tomi; Escartin, Terenz; Karim, Karim S.; Cunningham, Ian A.
2016-03-01
The ability to improve visualization of structural information in digital radiography without increasing radiation exposures requires improved image quality across all spatial frequencies, especially at high frequencies. The detective quantum efficiency (DQE) as a function of spatial frequency quantifies image quality given by an x-ray detector. We present a method of increasing DQE at high spatial frequencies by improving the modulation transfer function (MTF) and reducing noise aliasing. The Apodized Aperature Pixel (AAP) design uses a detector with micro-elements to synthesize desired pixels and provide higher DQE than conventional detector designs. A cascaded system analysis (CSA) that incorporates x-ray interactions is used for comparison of the theoretical MTF, noise power spectrum (NPS), and DQE. Signal and noise transfer through the converter material is shown to consist of correlated an uncorrelated terms. The AAP design was shown to improve the DQE of both material types that have predominantly correlated transfer (such as CsI) and predominantly uncorrelated transfer (such as Se). Improvement in the MTF by 50% and the DQE by 100% at the sampling cut-off frequency is obtained when uncorrelated transfer is prevalent through the converter material. Optimizing high-frequency DQE results in improved image contrast and visualization of small structures and fine-detail.
NASA Astrophysics Data System (ADS)
Druart, Guillaume; Rommeluere, Sylvain; Viale, Thibault; Guerineau, Nicolas; Ribet-Mohamed, Isabelle; Crastes, Arnaud; Durand, Alain; Taboury, Jean
2014-05-01
Today, both military and civilian applications require miniaturized and cheap optical systems. One way to achieve this trend consists in decreasing the pixel pitch of focal plane arrays (FPA). In order to evaluate the performance of the overall optical systems, it is necessary to measure the modulation transfer function (MTF) of these pixels. However, small pixels lead to higher cut-off frequencies and therefore, original MTF measurements that are able to extract frequencies up to these high cut-off frequencies, are needed. In this paper, we will present a way to extract 1D MTF at high frequencies by projecting fringes on the FPA. The device uses a Lloyd mirror placed near and perpendicular to the focal plane array. Consequently, an interference pattern of fringes can be projected on the detector. By varying the angle of incidence of the light beam, we can tune the period of the interference fringes and, thus, explore a wide range of spatial frequencies, and mainly around the cut-off frequency of the pixel which is one of the most interesting area. Illustration of this method will be applied to a 640×480 microbolometer focal plane array with a pixel pitch of 17µm in the LWIR spectral region.
Adams, Noah; Hitomi, Maaya; Moody, Cherie
2017-01-01
Abstract Purpose: This article reports on the findings of a meta-synthesis undertaken on published gray transgender suicidality literature, to determine the average rate of suicidal ideation and attempts in this population. Methods: Studies included in this synthesis were restricted to the 42 that reported on 5 or more Canadian or U.S. adult participants, as published between 1997 and February 2016 in either gray or peer-reviewed health literature. Results: Across these 42 studies an average of 55% of respondents ideated about and 29% attempted suicide in their lifetimes. Within the past year, these averages were, respectively, 51% and 11%, or 14 and 22 times that of the general public. Overall, suicidal ideation was higher among individuals of a male-to-female (MTF) than female-to-male (FTM) alignment, and lowest among those who were gender non-conforming (GNC). Conversely, attempts occurred most often among FTM individuals, then decreased for MTF individuals, followed by GNC individuals. Conclusion: These findings may be useful in creating targeted interventions that take into account both the alarmingly high rate of suicidality in this population, and the relatively differential experience of FTM, MTF, and GNC individuals. Future research should examine minority stress theory and suicidality protection/resilience factors, particularly transition, on this population. PMID:28861548
Application of Magnetized Target Fusion to High-Energy Space Propulsion
NASA Technical Reports Server (NTRS)
Thio, Y. C. F.; Schmidt, G. R.; Kirkpatrick, R. C.; Rodgers, Stephen L. (Technical Monitor)
2001-01-01
Most fusion propulsion concepts that have been investigated in the past employ some form of inertial or magnetic confinement. Although the prospective performance of these concepts is excellent, the fusion processes on which these concepts are based still require considerable development before they can be seriously considered for actual applications. Furthermore, these processes are encumbered by the need for sophisticated plasma and power handling systems that are generally quite inefficient and have historically resulted in large, massive spacecraft designs. Here we present a comparatively new approach, Magnetized Target Fusion (MTF), which offers a nearer-term avenue for realizing the tremendous performance benefits of fusion propulsion'. The key advantage of MTF is its less demanding requirements for driver energy and power processing. Additional features include: 1) very low system masses and volumes, 2) high gain and relatively low waste heat, 3) substantial utilization of energy from product neutrons, 4) efficient, low peak-power drivers based on existing pulsed power technology, and 5) very high Isp, specific power and thrust. MTF overcomes many of the problems associated with traditional fusion techniques, thus making it particularly attractive for space applications. Isp greater than 50,000 seconds and specific powers greater than 50 kilowatts/kilogram appear feasible using relatively near-term pulse power and plasma gun technology.
Clements-Nolle, Kristen; Guzman, Robert; Harris, Susan G
2008-03-01
Research suggests that because of economic necessity, many male-to-female (MTF) transgender individuals trade sex for money, drugs, housing, and other things they may need. To date, no studies have quantitatively assessed psychosocial correlates of condom use with this population. We conducted a cross sectional study with 190 MTF transgender individuals involved in sex trade in San Francisco, California. Multivariate logistic regression was used to determine factors independently associated with inconsistent condom use during receptive anal sex with exchange partners. About one fifth of our participants reported inconsistent condom use during receptive anal sex in the past 6 months. In the multivariate model, low self-esteem [adjusted odds ratio (AOR)=3.09; 95% confidence interval (CI) (1.28, 7.47)], a history of forced sex or rape [AOR=2.91; 95% CI (1.06, 8.01)], and use of crack-cocaine [AOR=2.59; 95% CI (1.09, 6.13)] were independently associated with inconsistent condom use. Our findings highlight an urgent need for multilevel risk reduction interventions for MTF transgender individuals involved in sex trade. Such interventions will be most effective if they address the psychosocial context of sexual risk taking by focusing on issues such as low self-esteem, sexual violence, and illicit drug use.
NASA Astrophysics Data System (ADS)
Lynn, Alan; Gilmore, Mark; Wynkoop, Tyler; Intrator, Thomas; Weber, Thomas
2012-10-01
Magnetized Target Fusion (MTF) is an innovative approach for a relatively fast and cheap path to the production of fusion energy that utilizes magnetic confinement to assist in the compression of a hot plasma to thermonuclear conditions by an external driver. Los Alamos National Laboratory (LANL) is currently pursing demonstration of the MTF concept via compression of an FRC (field-reversed configuration) plasma by a metal liner z-pinch in conjunction with the Air Force Research Laboratory in Albuquerque, NM. A key physics issue for the FRC as an MTF target lies in the initial pre-ionization (PI) stage. The PI formation process determines the amount of magnetic flux that can be trapped to form the FRC. This trapped flux plays an important role in the FRC's final equilibrium, transport, and stability properties. It also provides the route to greatest potential gains in FRC lifetime, which is essential to provide enough time to translate and compress the FRC effectively. In conjunction with LANL we plan to test and characterize a new system to improve the initial PI plasma formation. This system will use an array of plasma guns to form the initial plasma. Initial characterization of the plasma gun behavior will be presented.
NASA Astrophysics Data System (ADS)
Yuasa, T.; Akiba, M.; Takeda, T.; Kazama, M.; Hoshino, A.; Watanabe, Y.; Hyodo, K.; Dilmanian, F. A.; Akatsuka, T.; Itai, Y.
1997-10-01
We describe a new system of incoherent scatter computed tomography (ISCT) using monochromatic synchrotron X rays, and we discuss its potential to be used in in vivo imaging for medical use. The system operates on the basis of computed tomography (CT) of the first generation. The reconstruction method for ISCT uses the least squares method with singular value decomposition. The research was carried out at the BLNE-5A bending magnet beam line of the Tristan Accumulation Ring in KEK, Japan. An acrylic cylindrical phantom of 20-mm diameter containing a cross-shaped channel was imaged. The channel was filled with a diluted iodine solution with a concentration of 200 /spl mu/gI/ml. Spectra obtained with the system's high purity germanium (HPGe) detector separated the incoherent X-ray line from the other notable peaks, i.e., the iK/sub /spl alpha// and K/sub /spl beta/1/ X-ray fluorescent lines and the coherent scattering peak. CT images were reconstructed from projections generated by integrating the counts In the energy window centering around the incoherent scattering peak and whose width was approximately 2 keV. The reconstruction routine employed an X-ray attenuation correction algorithm. The resulting image showed more homogeneity than one without the attenuation correction.
NASA Astrophysics Data System (ADS)
Monnin, P.; Verdun, F. R.; Bosmans, H.; Rodríguez Pérez, S.; Marshall, N. W.
2017-07-01
This work proposes a method for assessing the detective quantum efficiency (DQE) of radiographic imaging systems that include both the x-ray detector and the antiscatter device. Cascaded linear analysis of the antiscatter device efficiency (DQEASD) with the x-ray detector DQE is used to develop a metric of system efficiency (DQEsys); the new metric is then related to the existing system efficiency parameters of effective DQE (eDQE) and generalized DQE (gDQE). The effect of scatter on signal transfer was modelled through its point spread function (PSF), leading to an x-ray beam transfer function (BTF) that multiplies with the classical presampling modulation transfer function (MTF) to give the system MTF. Expressions are then derived for the influence of scattered radiation on signal-difference to noise ratio (SDNR) and contrast-detail (c-d) detectability. The DQEsys metric was tested using two digital mammography systems, for eight x-ray beams (four with and four without scatter), matched in terms of effective energy. The model was validated through measurements of contrast, SDNR and MTF for poly(methyl)methacrylate thicknesses covering the range of scatter fractions expected in mammography. The metric also successfully predicted changes in c-d detectability for different scatter conditions. Scatter fractions for the four beams with scatter were established with the beam stop method using an extrapolation function derived from the scatter PSF, and validated through Monte Carlo (MC) simulations. Low-frequency drop of the MTF from scatter was compared to both theory and MC calculations. DQEsys successfully quantified the influence of the grid on SDNR and accurately gave the break-even object thickness at which system efficiency was improved by the grid. The DQEsys metric is proposed as an extension of current detector characterization methods to include a performance evaluation in the presence of scattered radiation, with an antiscatter device in place.
2MTF - VI. Measuring the velocity power spectrum
NASA Astrophysics Data System (ADS)
Howlett, Cullan; Staveley-Smith, Lister; Elahi, Pascal J.; Hong, Tao; Jarrett, Tom H.; Jones, D. Heath; Koribalski, Bärbel S.; Macri, Lucas M.; Masters, Karen L.; Springob, Christopher M.
2017-11-01
We present measurements of the velocity power spectrum and constraints on the growth rate of structure fσ8, at redshift zero, using the peculiar motions of 2062 galaxies in the completed 2MASS Tully-Fisher survey (2MTF). To accomplish this we introduce a model for fitting the velocity power spectrum including the effects of non-linear redshift space distortions (RSD), allowing us to recover unbiased fits down to scales k = 0.2 h Mpc-1 without the need to smooth or grid the data. Our fitting methods are validated using a set of simulated 2MTF surveys. Using these simulations we also identify that the Gaussian distributed estimator for peculiar velocities of Watkins & Feldman is suitable for measuring the velocity power spectrum, but sub-optimal for the 2MTF data compared to using magnitude fluctuations δm, and that, whilst our fits are robust to a change in fiducial cosmology, future peculiar velocity surveys with more constraining power may have to marginalize over this. We obtain scale-dependent constraints on the growth rate of structure in two bins, finding fσ 8 = [0.55^{+0.16}_{-0.13},0.40^{+0.16}_{-0.17}] in the ranges k = [0.007-0.055, 0.55-0.150] h Mpc-1. We also find consistent results using four bins. Assuming scale-independence we find a value fσ 8 = 0.51^{+0.09}_{-0.08}, a ˜16 per cent measurement of the growth rate. Performing a consistency check of general relativity (GR) and combining our results with cosmic microwave background data only we find γ = 0.45^{+0.10}_{-0.11}, a remarkable constraint considering the small number of galaxies. All of our results are completely independent of the effects of galaxy bias, and fully consistent with the predictions of GR (scale-independent fσ8 and γ ≈ 0.55).
Physics considerations in MV-CBCT multi-layer imager design.
Hu, Yue-Houng; Fueglistaller, Rony; Myronakis, Marios E; Rottmann, Joerg; Wang, Adam; Shedlock, Daniel; Morf, Daniel; Baturin, Paul; Huber, Pascal; Star-Lack, Josh M; Berbeco, Ross I
2018-05-30
Megavoltage (MV) cone-beam computed tomography (CBCT) using an electronic portal imaging (EPID) offers advantageous features, including 3D mapping, treatment beam registration, high-z artifact suppression, and direct radiation dose calculation. Adoption has been slowed by image quality limitations and concerns about imaging dose. Developments in imager design, including pixelated scintillators, structured phosphors, inexpensive scintillation materials, and multi-layer imager (MLI) architecture have been explored to improve EPID image quality and reduce imaging dose. The present study employs a hybrid Monte Carlo and linear systems model to determine the effect of detector design elements, such as multi-layer architecture and scintillation materials. We follow metrics of image quality including modulation transfer function (MTF) and noise power spectrum (NPS) from projection images to 3D reconstructions to in-plane slices and apply a task based figure-of-merit, the ideal observer signal-to-noise ratio (d') to determine the effect of detector design on object detectability. Generally, detectability was limited by detector noise performance. Deploying an MLI imager with a single scintillation material for all layers yields improvement in noise performance and d' linear with the number of layers. In general, improving x-ray absorption using thicker scintillators results in improved DQE(0). However, if light yield is low, performance will be affected by electronic noise at relatively high doses, resulting in rapid image quality degradation. Maximizing image quality in a heterogenous MLI detector (i.e. multiple different scintillation materials) is most affected by limiting imager noise. However, while a second-order effect, maximizing total spatial resolution of the MLI detector is a balance between the intensity contribution of each layer against its individual MTF. So, while a thinner scintillator may yield a maximal individual-layer MTF, its quantum efficiency will be relatively low in comparison to a thicker scintillator and thus, intensity contribution may be insufficient to noticeably improve the total detector MTF. © 2018 Institute of Physics and Engineering in Medicine.
Transgender Transitioning and Change of Self-Reported Sexual Orientation
Höhne, Nina; Stalla, Günter K.; Sievers, Caroline
2014-01-01
Objective Sexual orientation is usually considered to be determined in early life and stable in the course of adulthood. In contrast, some transgender individuals report a change in sexual orientation. A common reason for this phenomenon is not known. Methods We included 115 transsexual persons (70 male-to-female “MtF” and 45 female-to-male “FtM”) patients from our endocrine outpatient clinic, who completed a questionnaire, retrospectively evaluating the history of their gender transition phase. The questionnaire focused on sexual orientation and recalled time points of changes in sexual orientation in the context of transition. Participants were further asked to provide a personal concept for a potential change in sexual orientation. Results In total, 32.9% (n = 23) MtF reported a change in sexual orientation in contrast to 22.2% (n = 10) FtM transsexual persons (p = 0.132). Out of these patients, 39.1% (MtF) and 60% (FtM) reported a change in sexual orientation before having undergone any sex reassignment surgery. FtM that had initially been sexually oriented towards males ( = androphilic), were significantly more likely to report on a change in sexual orientation than gynephilic, analloerotic or bisexual FtM (p = 0.012). Similarly, gynephilic MtF reported a change in sexual orientation more frequently than androphilic, analloerotic or bisexual MtF transsexual persons (p = 0.05). Conclusion In line with earlier reports, we reveal that a change in self-reported sexual orientation is frequent and does not solely occur in the context of particular transition events. Transsexual persons that are attracted by individuals of the opposite biological sex are more likely to change sexual orientation. Qualitative reports suggest that the individual's biography, autogynephilic and autoandrophilic sexual arousal, confusion before and after transitioning, social and self-acceptance, as well as concept of sexual orientation itself may explain this phenomenon. PMID:25299675
Sinusoidal modulation analysis for optical system MTF measurements.
Boone, J M; Yu, T; Seibert, J A
1996-12-01
The modulation transfer function (MTF) is a commonly used metric for defining the spatial resolution characteristics of imaging systems. While the MTF is defined in terms of how an imaging system demodulates the amplitude of a sinusoidal input, this approach has not been in general use to measure MTFs in the medical imaging community because producing sinusoidal x-ray patterns is technically difficult. However, for optical systems such as charge coupled devices (CCD), which are rapidly becoming a part of many medical digital imaging systems, the direct measurement of modulation at discrete spatial frequencies using a sinusoidal test pattern is practical. A commercially available optical test pattern containing spatial frequencies ranging from 0.375 cycles/mm to 80 cycles/mm was sued to determine the MRF of a CCD-based optical system. These results were compared with the angulated slit method of Fujita [H. Fujita, D. Tsia, T. Itoh, K. Doi, J. Morishita, K. Ueda, and A. Ohtsuka, "A simple method for determining the modulation transfer function in digital radiography," IEEE Trans. Medical Imaging 11, 34-39 (1992)]. The use of a semiautomated profiled iterated reconstruction technique (PIRT) is introduced, where the shift factor between successive pixel rows (due to angulation) is optimized iteratively by least-squares error analysis rather than by hand measurement of the slit angle. PIRT was used to find the slit angle for the Fujita technique and to find the sine-pattern angle for the sine-pattern technique. Computer simulation of PIRT for the case of the slit image (a line spread function) demonstrated that it produced a more accurate angle determination than "hand" measurement, and there is a significant difference between the errors in the two techniques (Wilcoxon Signed Rank Test, p < 0.001). The sine-pattern method and the Fujita slit method produced comparable MTF curves for the CCD camera evaluated.
Favazza, Christopher P; Duan, Xinhui; Zhang, Yi; Yu, Lifeng; Leng, Shuai; Kofler, James M; Bruesewitz, Michael R; McCollough, Cynthia H
2015-11-07
Through this investigation we developed a methodology to evaluate and standardize CT image quality from routine abdomen protocols across different manufacturers and models. The influence of manufacturer-specific automated exposure control systems on image quality was directly assessed to standardize performance across a range of patient sizes. We evaluated 16 CT scanners across our health system, including Siemens, GE, and Toshiba models. Using each practice's routine abdomen protocol, we measured spatial resolution, image noise, and scanner radiation output (CTDIvol). Axial and in-plane spatial resolutions were assessed through slice sensitivity profile (SSP) and modulation transfer function (MTF) measurements, respectively. Image noise and CTDIvol values were obtained for three different phantom sizes. SSP measurements demonstrated a bimodal distribution in slice widths: an average of 6.2 ± 0.2 mm using GE's 'Plus' mode reconstruction setting and 5.0 ± 0.1 mm for all other scanners. MTF curves were similar for all scanners. Average spatial frequencies at 50%, 10%, and 2% MTF values were 3.24 ± 0.37, 6.20 ± 0.34, and 7.84 ± 0.70 lp cm(-1), respectively. For all phantom sizes, image noise and CTDIvol varied considerably: 6.5-13.3 HU (noise) and 4.8-13.3 mGy (CTDIvol) for the smallest phantom; 9.1-18.4 HU and 9.3-28.8 mGy for the medium phantom; and 7.8-23.4 HU and 16.0-48.1 mGy for the largest phantom. Using these measurements and benchmark SSP, MTF, and image noise targets, CT image quality can be standardized across a range of patient sizes.
Bentz, Eva-Katrin; Hefler, Lukas A; Kaufmann, Ulrike; Huber, Johannes C; Kolbus, Andrea; Tempfer, Clemens B
2008-07-01
To assess the association between transsexualism and allele and genotype frequencies of the common cytochrome P450 (CYP) 17 -34 T>C single nucleotide polymorphism (SNP). Case-control study. Academic research institution. 102 male-to-female (MtF) and 49 female-to-male (FtM) transsexuals, 756 male controls, and 915 female controls. Buccal swabs and multiplex polymerase chain reaction on a microarray system. Analysis of the CYP17 -34 T>C SNP. CYP17 -34 T>C SNP allele frequencies were statistically significantly different between FtM transsexuals and female controls (CYP17 T: 55/98 [56%] and CYP17 C: 43/98 [44%] versus CYP17 T: 1253/1826 [69%] and CYP17 C: 573/1826 [31%], respectively). In accordance, genotype distributions were also different between FtM transsexuals and female controls using a recessive genotype model (CYP17 T/T+T/C: 39/49 [80%] and C/C 10/49 [20%] vs. CYP17 T/T+T/C: 821/913 [90%] and C/C 92/913 [10%], respectively). The CYP17 -34 T>C allele and genotype distributions were not statistically significantly different between MtF transsexuals and male controls. Of note, the CYP17 -34 T>C allele distribution was gender-specific among controls (CYP17 C: males; 604 of 1512 [40%] vs. females; 573 of 1826 [31%]). The MtF transsexuals had an allele distribution equivalent to male controls, whereas FtM transsexuals did not follow the gender-specific allele distribution of female controls but rather had an allele distribution equivalent to MtF transsexuals and male controls. These data support CYP17 as a candidate gene of FtM transsexualism and indicate that loss of a female-specific CYP17 T -34C allele distribution pattern is associated with FtM transsexualism.
The Wigner–Yanase information can increase under phase sensitive incoherent operations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Du, Shuanping, E-mail: shuanpingdu@yahoo.com; Bai, Zhaofang, E-mail: baizhaofang@xmu.edu.cn
2015-08-15
We found that the Wigner-Yanase skew information, which has been recently proposed as a measure of coherence in Girolami (2014), can increase under a class of operations which may be interpreted as incoherent following the framework of Baumgratz et al., while being phase sensitive.
Retrospective analysis of a detector fault for a full field digital mammography system
NASA Astrophysics Data System (ADS)
Marshall, N. W.
2006-11-01
This paper describes objective and subjective image quality measurements acquired as part of a routine quality assurance (QA) programme for an amorphous selenium (a-Se) full field digital mammography (FFDM) system between August-04 and February-05. During this period, the FFDM detector developed a fault and was replaced. A retrospective analysis of objective image quality parameters (modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE)) is presented to try and gain a deeper understanding of the detector problem that occurred. These measurements are discussed in conjunction with routine contrast-detail (c-d) results acquired with the CDMAM (Artinis, The Netherlands) test object. There was significant reduction in MTF over this period of time indicating an increase in blurring occurring within the a-Se converter layer. This blurring was not isotropic, being greater in the data line direction (left to right across the detector) than in the gate line direction (chest wall to nipple). The initial value of the 50% MTF point was 6 mm-1; for the faulty detector the 50% MTF points occurred at 3.4 mm-1 and 1.0 mm-1 in the gate line and data line directions, respectively. Prior to NNPS estimation, variance images were formed of the detector flat field images. Spatial distribution of variance was not uniform, suggesting that the physical blurring process was not constant across the detector. This change in variance with image position implied that the stationarity of the noise statistics within the image was limited and that care would be needed when performing objective measurements. The NNPS measurements confirmed the results found for the MTF, with a strong reduction in NNPS as a function of spatial frequency. This reduction was far more severe in the data line direction. A somewhat tentative DQE estimate was made; in the gate line direction there was little change in DQE up to 2.5 mm-1 but at the Nyquist frequency the DQE had fallen to approximately 35% of the original value. There was severe attenuation of DQE in the data line direction, the DQE falling to less than 0.01 above approximately 3.0 mm-1. C-d results showed an increase in threshold contrast of approximately 25% for details less than 0.2 mm in diameter, while no reduction in c-d performance was found at the largest detail diameters (1.0 mm and above). Despite the detector fault, the c-d curve was found to pass the European protocol acceptable c-d curve.
Cascaded systems analysis of photon counting detectors
Xu, J.; Zbijewski, W.; Gang, G.; Stayman, J. W.; Taguchi, K.; Lundqvist, M.; Fredenberg, E.; Carrino, J. A.; Siewerdsen, J. H.
2014-01-01
Purpose: Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). Methods: A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1–7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. Results: The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f50 (spatial-frequency at which the MTF falls to a value of 0.50) by ∼30% with corresponding improvement in DQE. The range in exposure and additive noise for which PCDs yield intrinsically higher DQE was quantified, showing performance advantages under conditions of very low-dose, high additive noise, and high fidelity rejection of coincident photons. Conclusions: The model for PCD signal and noise performance agreed with measurements of detector signal, MTF, and NPS and provided a useful basis for understanding complex dependencies in PCD imaging performance and the potential advantages (and disadvantages) in comparison to EIDs as well as an important guide to task-based optimization in developing new PCD imaging systems. PMID:25281959
Cascaded systems analysis of photon counting detectors.
Xu, J; Zbijewski, W; Gang, G; Stayman, J W; Taguchi, K; Lundqvist, M; Fredenberg, E; Carrino, J A; Siewerdsen, J H
2014-10-01
Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1-7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f50 (spatial-frequency at which the MTF falls to a value of 0.50) by ∼30% with corresponding improvement in DQE. The range in exposure and additive noise for which PCDs yield intrinsically higher DQE was quantified, showing performance advantages under conditions of very low-dose, high additive noise, and high fidelity rejection of coincident photons. The model for PCD signal and noise performance agreed with measurements of detector signal, MTF, and NPS and provided a useful basis for understanding complex dependencies in PCD imaging performance and the potential advantages (and disadvantages) in comparison to EIDs as well as an important guide to task-based optimization in developing new PCD imaging systems.
Matysik, Piotr; Jóźwiak, Stanisław; Czujko, Tomasz
2015-03-04
Fe-Al intermetallic alloys with aluminum content over 60 at% are in the area of the phase equilibrium diagram that is considerably less investigated in comparison to the high-symmetry Fe₃Al and FeAl phases. Ambiguous crystallographic information and incoherent data referring to the phase equilibrium diagrams placed in a high-aluminum range have caused confusions and misinformation. Nowadays unequivocal material properties description of FeAl₂, Fe₂Al₅ and FeAl₃ intermetallic alloys is still incomplete. In this paper, the influence of aluminum content and processing parameters on phase composition is presented. The occurrence of low-symmetry FeAl₂, Fe₂Al₅ and FeAl₃ structures determined by chemical composition and phase transformations was defined by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) examinations. These results served to verify diffraction investigations (XRD) and to explain the mechanical properties of cast materials such as: hardness, Young's modulus and fracture toughness evaluated using the nano-indentation technique.
Nuclear EMP simulation for large-scale urban environments. FDTD for electrically large problems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, William S.; Bull, Jeffrey S.; Wilcox, Trevor
2012-08-13
In case of a terrorist nuclear attack in a metropolitan area, EMP measurement could provide: (1) a prompt confirmation of the nature of the explosion (chemical or nuclear) for emergency response; and (2) and characterization parameters of the device (reaction history, yield) for technical forensics. However, urban environment could affect the fidelity of the prompt EMP measurement (as well as all other types of prompt measurement): (1) Nuclear EMP wavefront would no longer be coherent, due to incoherent production, attenuation, and propagation of gamma and electrons; and (2) EMP propagation from source region outward would undergo complicated transmission, reflection, andmore » diffraction processes. EMP simulation for electrically-large urban environment: (1) Coupled MCNP/FDTD (Finite-difference time domain Maxwell solver) approach; and (2) FDTD tends to be limited to problems that are not 'too' large compared to the wavelengths of interest because of numerical dispersion and anisotropy. We use a higher-order low-dispersion, isotropic FDTD algorithm for EMP propagation.« less
Quantifying adsorption-induced deformation of nanoporous materials on different length scales
Morak, Roland; Braxmeier, Stephan; Ludescher, Lukas; Hüsing, Nicola; Reichenauer, Gudrung
2017-01-01
A new in situ setup combining small-angle neutron scattering (SANS) and dilatometry was used to measure water-adsorption-induced deformation of a monolithic silica sample with hierarchical porosity. The sample exhibits a disordered framework consisting of macropores and struts containing two-dimensional hexagonally ordered cylindrical mesopores. The use of an H2O/D2O water mixture with zero scattering length density as an adsorptive allows a quantitative determination of the pore lattice strain from the shift of the corresponding diffraction peak. This radial strut deformation is compared with the simultaneously measured macroscopic length change of the sample with dilatometry, and differences between the two quantities are discussed on the basis of the deformation mechanisms effective at the different length scales. It is demonstrated that the SANS data also provide a facile way to quantitatively determine the adsorption isotherm of the material by evaluating the incoherent scattering contribution of H2O at large scattering vectors. PMID:29021735
Far-field nanoscopy on a semiconductor quantum dot via a rapid-adiabatic-passage-based switch
NASA Astrophysics Data System (ADS)
Kaldewey, Timo; Kuhlmann, Andreas V.; Valentin, Sascha R.; Ludwig, Arne; Wieck, Andreas D.; Warburton, Richard J.
2018-02-01
The diffraction limit prevents a conventional optical microscope from imaging at the nanoscale. However, nanoscale imaging of molecules is possible by exploiting an intensity-dependent molecular switch1-3. This switch is translated into a microscopy scheme, stimulated emission depletion microscopy4-7. Variants on this scheme exist3,8-13, yet all exploit an incoherent response to the lasers. We present a scheme that relies on a coherent response to a laser. Quantum control of a two-level system proceeds via rapid adiabatic passage, an ideal molecular switch. We implement this scheme on an ensemble of quantum dots. Each quantum dot results in a bright spot in the image with extent down to 30 nm (λ/31). There is no significant loss of intensity with respect to confocal microscopy, resulting in a factor of 10 improvement in emitter position determination. The experiments establish rapid adiabatic passage as a versatile tool in the super-resolution toolbox.
Shock induced damage in copper: A before and after, three-dimensional study
NASA Astrophysics Data System (ADS)
Menasche, David B.; Lind, Jonathan; Li, Shiu Fai; Kenesei, Peter; Bingert, John F.; Lienert, Ulrich; Suter, Robert M.
2016-04-01
We report on the microstructural features associated with the formation of incipient spall and damage in a fully recrystallized, high purity copper sample. Before and after ballistic shock loading, approximately 0.8 mm3 of the sample's crystal lattice orientation field is mapped using non-destructive near-field High Energy Diffraction Microscopy. Absorption contrast tomography is used to image voids after loading. This non-destructive interrogation of damage initiation allows for novel characterization of spall points vis-a-vis microstructural features and a fully 3D examination of microstructural topology and its influence on incipient damage. The spalled region is registered with and mapped back onto the pre-shock orientation field. As expected, the great majority of voids occur at grain boundaries and higher order microstructural features; however, we find no statistical preference for particular grain boundary types. The damaged region contains a large volume of Σ-3 (60 °<111 >) connected domains with a large area fraction of incoherent Σ-3 boundaries.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lynn, Alan
2013-11-01
The University of New Mexico (UNM) proposed a collaboration with Los Alamos National Laboratory (LANL) to develop and test methods for improved formation of field-reversed configuration (FRC) plasmas relevant to magnetized target fusion (MTF) energy research. MTF is an innovative approach for a relatively fast and cheap path to the production of fusion energy that utilizes magnetic confinement to assist in the compression of a hot plasma to thermonuclear conditions by an external driver. LANL is currently pursing demonstration of the MTF concept via compression of an FRC plasma by a metal liner z-pinch in conjunction with the Air Forcemore » Research Laboratory in Albuquerque, NM. A key physics issue for the FRC's ultimate success as an MTF target lies in the initial pre-ionization (PI) stage. The PI plasma sets the initial conditions from which the FRC is created. In particular, the PI formation process determines the amount of magnetic flux that can be trapped to form the FRC. A ringing theta pinch ionization (RTPI) technique, such as currently used by the FRX-L device at LANL, has the advantages of high ionization fraction, simplicity (since no additional coils are required), and does not require internal electrodes which can introduce impurities into the plasma. However RTPI has been shown to only trap 50% of the initial bias flux at best and imposes additional engineering constraints on the capacitor banks. The amount of trapped flux plays an important role in the FRC's final equilibrium, transport, and stability properties, and provides increased ohmic heating of the FRC through induced currents as the magnetic field decays. Increasing the trapped flux also provides the route to greatest potential gains in FRC lifetime, which is essential to provide enough time to translate and compress the FRC effectively. In conjunction with LANL we initially planned to develop and test a microwave break- down system to improve the initial PI plasma formation. The UNM team would design the microwave optics and oversee the fabrication and assembly of all components and assist with integration into the FRX-L machine control system. LANL would provide a preexisting 65 kW X-band microwave source and some associated waveguide hardware. Once constructed and installed, UNM would take the lead in operating the microwave breakdown system and conducting studies to optimize its use in FRC PI formation in close cooperation with the needs of the LANL MTF team. In conjunction with our LANL collaborators, we decided after starting the project to switch from a microwave plasma breakdown approach to a plasma gun technology to use for enhanced plasma formation in the FRX-L field-reversed configuration experiment at LANL. Plasma guns would be able to provide significantly higher density plasma with greater control over its distribution in time and space within the experiment. This would allow greater control and ne-tuning of the PI plasma formed in the experiment. Multiple plasma guns would be employed to fill a Pyrex glass test chamber (built at UNM) with plasma which would then be characterized and optimized for the MTF effort.« less
Incoherence-Mediated Remote Synchronization
NASA Astrophysics Data System (ADS)
Zhang, Liyue; Motter, Adilson E.; Nishikawa, Takashi
2017-04-01
In previously identified forms of remote synchronization between two nodes, the intermediate portion of the network connecting the two nodes is not synchronized with them but generally exhibits some coherent dynamics. Here we report on a network phenomenon we call incoherence-mediated remote synchronization (IMRS), in which two noncontiguous parts of the network are identically synchronized while the dynamics of the intermediate part is statistically and information-theoretically incoherent. We identify mirror symmetry in the network structure as a mechanism allowing for such behavior, and show that IMRS is robust against dynamical noise as well as against parameter changes. IMRS may underlie neuronal information processing and potentially lead to network solutions for encryption key distribution and secure communication.
Vibronic dephasing model for coherent-to-incoherent crossover in DNA
NASA Astrophysics Data System (ADS)
Karasch, Patrick; Ryndyk, Dmitry A.; Frauenheim, Thomas
2018-05-01
In this paper, we investigate the interplay between coherent and incoherent charge transport in cytosine-guanine (GC-) rich DNA molecules. Our objective is to introduce a physically grounded approach to dephasing in large molecules and to understand the length-dependent charge transport characteristics, and especially the crossover from the coherent tunneling to incoherent hopping regime at different temperatures. Therefore, we apply the vibronic dephasing model and compare the results to the Büttiker probe model which is commonly used to describe decoherence effects in charge transport. Using the full ladder model and simplified one-dimensional model of DNA, we consider molecular junctions with alternating and stacked GC sequences and compare our results to recent experimental measurements.
Depth-resolved incoherent and coherent wide-field high-content imaging (Conference Presentation)
NASA Astrophysics Data System (ADS)
So, Peter T.
2016-03-01
Recent advances in depth-resolved wide-field imaging technique has enabled many high throughput applications in biology and medicine. Depth resolved imaging of incoherent signals can be readily accomplished with structured light illumination or nonlinear temporal focusing. The integration of these high throughput systems with novel spectroscopic resolving elements further enable high-content information extraction. We will introduce a novel near common-path interferometer and demonstrate its uses in toxicology and cancer biology applications. The extension of incoherent depth-resolved wide-field imaging to coherent modality is non-trivial. Here, we will cover recent advances in wide-field 3D resolved mapping of refractive index, absorbance, and vibronic components in biological specimens.
Numerical analysis of the chimera states in the multilayered network model
NASA Astrophysics Data System (ADS)
Goremyko, Mikhail V.; Maksimenko, Vladimir A.; Makarov, Vladimir V.; Ghosh, Dibakar; Bera, Bidesh K.; Dana, Syamal K.; Hramov, Alexander E.
2017-03-01
We numerically study the interaction between the ensembles of the Hindmarsh-Rose (HR) neuron systems, arranged in the multilayer network model. We have shown that the fully identical layers, demonstrated individually different chimera due to the initial mismatch, come to the identical chimera state with the increase of inter-layer coupling. Within the multilayer model we also consider the case, when the one layer demonstrates chimera state, while another layer exhibits coherent or incoherent dynamics. It has been shown that the interactions chimera-coherent state and chimera-incoherent state leads to the both excitation of chimera as from the ensemble of fully coherent or incoherent oscillators, and suppression of initially stable chimera state
Plasma Liner Development for MTF Applications: A Status Report
NASA Technical Reports Server (NTRS)
Eskridge, R. E.; Thio, Y. F.; Lee, M.; Martin, A.; Smith, J. W.; Griffin, S. T.; Schafer, Charles (Technical Monitor)
2001-01-01
An experimental plasma gun for Magnetic Target Fusion (MTF) applications under development at the NASA Marshall Space Flight Center is described. This gun has been tested experimentally and plasma jet velocities of approximately 50 km/sec have been obtained. The plasma jet structure has been photographed with 10 ns exposure times to reveal a stable and repeatable plasma structure. Data for velocity profile information has been obtained using light pipes embedded in the gun walls to record the plasma transit at various barrel locations. A high speed triggering system has been developed and tested as a means of reducing the gun "jitter". This jitter has been characterized and future work for second generation "ultra-low jitter" gun development is identified.
NASA Astrophysics Data System (ADS)
Ortiz, Dolores; Saiz, Jose M.; González, Francisco
2004-04-01
The presence of local inhomogeneities in corneal tissue after refractive surgery has an influence on visual performance. Here we focus on the corneal ablation associated with Lasik surgery and its effect on the modulation transfer function (MTF) that we obtained by modifying a personalized Kooijman model. Inhomogeneities induced by the ablation occur in the form of Gaussian-distributed refractive-index variations of a given correlation length. We show how variation of refractive-index deviation and correlation length (size) of the inhomogeneities allows us to obtain pairs of values that are able to achieve a MTF evolution similar to that observed for contrast sensitivity in the same patients. An estimate of the characteristics of the local effects is obtained.
LANDSAT-4 Thematic Mapper Modulation Transfer Function (MTF) evaluation
NASA Technical Reports Server (NTRS)
Schowengerdt, R. (Principal Investigator)
1985-01-01
The Modulation Transfer Function (MTF) for thematic mapping (TM) bands 3, 4, 5 and 7 is reliably estimated with the San Mateo Bridge target in the 12/31/82 scene. These results are to be compared with those from the 8/12/83 scene. Bands 1, 2 and 6 are to be analyzed with a different target possessing greater contrast. This may be possible with the underflight data comparison currently underway. The registration of this data to the TM image of 8/12/83 for a region arround the Stockton sewage pond east of San Francisco has begun. This particular approach has the advantage that the full two-dimensional MFT will be measured instead of the MFT in only one azimuth as reported.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Birch, Gabriel Carisle; Griffin, John Clark
2015-01-01
The horizontal television lines (HTVL) metric has been the primary quantity used by division 6000 related to camera resolution for high consequence security systems. This document shows HTVL measurements are fundamen- tally insufficient as a metric to determine camera resolution, and propose a quantitative, standards based methodology by measuring the camera system modulation transfer function (MTF), the most common and accepted metric of res- olution in the optical science community. Because HTVL calculations are easily misinterpreted or poorly defined, we present several scenarios in which HTVL is frequently reported, and discuss their problems. The MTF metric is discussed, and scenariosmore » are presented with calculations showing the application of such a metric.« less
Optical-to-optical interface device
NASA Technical Reports Server (NTRS)
Jacobson, A. D.; Bleha, W. P.; Miller, L.; Grinberg, J.; Fraas, L.; Margerum, D.
1975-01-01
An investigation was conducted to develop an optical-to-optical interface device capable of performing real-time incoherent-to-incoherent optical image conversion. The photoactivated liquid crystal light valve developed earlier represented a prototype liquid crystal light valve device capable of performing these functions. A device was developed which had high performance and extended lifetime.
The Fateful Rift: The San Andreas Fault in the Modern Mind.
ERIC Educational Resources Information Center
Percy, Walker
1990-01-01
Claims that modern science is radically incoherent and that this incoherence lies within the practice of science. Details the work of the scientist and philosopher Charles Sanders Pierce, expounding on the difference between Rene Descartes' dualistic philosophy and Pierce's triadic view. Concludes with a brief description of the human existence.…
Interference detection and correction applied to incoherent-scatter radar power spectrum measurement
NASA Technical Reports Server (NTRS)
Ying, W. P.; Mathews, J. D.; Rastogi, P. K.
1986-01-01
A median filter based interference detection and correction technique is evaluated and the method applied to the Arecibo incoherent scatter radar D-region ionospheric power spectrum is discussed. The method can be extended to other kinds of data when the statistics involved in the process are still valid.
Digital holographic 3D imaging spectrometry (a review)
NASA Astrophysics Data System (ADS)
Yoshimori, Kyu
2017-09-01
This paper reviews recent progress in the digital holographic 3D imaging spectrometry. The principle of this method is a marriage of incoherent holography and Fourier transform spectroscopy. Review includes principle, procedure of signal processing and experimental results to obtain a multispectral set of 3D images for spatially incoherent, polychromatic objects.