Sample records for increased sampling rates

  1. Temperature dependence on the pesticide sampling rate of polar organic chemical integrative samplers (POCIS).

    PubMed

    Yabuki, Yoshinori; Nagai, Takashi; Inao, Keiya; Ono, Junko; Aiko, Nobuyuki; Ohtsuka, Nobutoshi; Tanaka, Hitoshi; Tanimori, Shinji

    2016-10-01

    Laboratory experiments were performed to determine the sampling rates of pesticides for the polar organic chemical integrative samplers (POCIS) used in Japan. The concentrations of pesticides in aquatic environments were estimated from the accumulated amounts of pesticide on POCIS, and the effect of water temperature on the pesticide sampling rates was evaluated. The sampling rates of 48 pesticides at 18, 24, and 30 °C were obtained, and this study confirmed that increasing trend of sampling rates was resulted with increasing water temperature for many pesticides.

  2. Passive air sampling theory for semivolatile organic compounds.

    PubMed

    Bartkow, Michael E; Booij, Kees; Kennedy, Karen E; Müller, Jochen F; Hawker, Darryl W

    2005-07-01

    The mathematical modelling underlying passive air sampling theory can be based on mass transfer coefficients or rate constants. Generally, these models have not been inter-related. Starting with basic models, the exchange of chemicals between the gaseous phase and the sampler is developed using mass transfer coefficients and rate constants. Importantly, the inter-relationships between the approaches are demonstrated by relating uptake rate constants and loss rate constants to mass transfer coefficients when either sampler-side or air-side resistance is dominating chemical exchange. The influence of sampler area and sampler volume on chemical exchange is discussed in general terms and as they relate to frequently used parameters such as sampling rates and time to equilibrium. Where air-side or sampler-side resistance dominates, an increase in the surface area of the sampler will increase sampling rates. Sampling rates are not related to the sampler/air partition coefficient (K(SV)) when air-side resistance dominates and increase with K(SV) when sampler-side resistance dominates.

  3. Effects of sample size on estimates of population growth rates calculated with matrix models.

    PubMed

    Fiske, Ian J; Bruna, Emilio M; Bolker, Benjamin M

    2008-08-28

    Matrix models are widely used to study the dynamics and demography of populations. An important but overlooked issue is how the number of individuals sampled influences estimates of the population growth rate (lambda) calculated with matrix models. Even unbiased estimates of vital rates do not ensure unbiased estimates of lambda-Jensen's Inequality implies that even when the estimates of the vital rates are accurate, small sample sizes lead to biased estimates of lambda due to increased sampling variance. We investigated if sampling variability and the distribution of sampling effort among size classes lead to biases in estimates of lambda. Using data from a long-term field study of plant demography, we simulated the effects of sampling variance by drawing vital rates and calculating lambda for increasingly larger populations drawn from a total population of 3842 plants. We then compared these estimates of lambda with those based on the entire population and calculated the resulting bias. Finally, we conducted a review of the literature to determine the sample sizes typically used when parameterizing matrix models used to study plant demography. We found significant bias at small sample sizes when survival was low (survival = 0.5), and that sampling with a more-realistic inverse J-shaped population structure exacerbated this bias. However our simulations also demonstrate that these biases rapidly become negligible with increasing sample sizes or as survival increases. For many of the sample sizes used in demographic studies, matrix models are probably robust to the biases resulting from sampling variance of vital rates. However, this conclusion may depend on the structure of populations or the distribution of sampling effort in ways that are unexplored. We suggest more intensive sampling of populations when individual survival is low and greater sampling of stages with high elasticities.

  4. The role of hydrodynamics, matrix and sampling duration in passive sampling of polar compounds with Empore SDB-RPS disks.

    PubMed

    Vermeirssen, Etiënne L M; Asmin, Josef; Escher, Beate I; Kwon, Jung-Hwan; Steimen, Irene; Hollender, Juliane

    2008-01-01

    There is an increasing need to monitor concentrations of polar organic contaminants in the aquatic environment. Integrative passive samplers can be used to assess time weighted average aqueous concentrations, provided calibration data are available and sampling rates are known. The sampling rate depends on environmental factors, such as temperature and water flow rate. Here we introduce an apparatus to investigate the sampling properties of passive samplers using river-like flow conditions and ambient environmental matrices: river water and treated sewage effluent. As a model sampler we selected Empore SDB-RPS disks in a Chemcatcher housing. The disks were exposed for 1 to 8 days at flow rates between 0.03 and 0.4 m s(-1). Samples were analysed using a bioassay for estrogenic activity and by LC-MS-MS target analysis of the pharmaceuticals sulfamethoxazole, carbamazepine and clarithromycin. In order to assess sampling rates of SDB disks, we also measured aqueous concentrations of the pharmaceuticals. Sampling rates increased with increasing flow rate and this relationship was not affected by the environmental matrix. However, SDB disks were only sampling in the integrative mode at low flow rates <0.1 m s(-1) and/or for short sampling times. The duration of linear uptake was particularly short for sulfamethoxazole (1 day) and longer for clarithromycin (5 days). At 0.03 m s(-1) and 12-14 degrees C, the sampling rate of SDB disks was 0.09 L day(-1) for clarithromycin, 0.14 L day(-1) for sulfamethoxazole and 0.25 L day(-1) for carbamazepine. The results show that under controlled conditions, SDB disks can be effectively used as passive sampling devices.

  5. Melting temperature and enthalpy variations of phase change materials (PCMs): a differential scanning calorimetry (DSC) analysis

    NASA Astrophysics Data System (ADS)

    Sun, Xiaoqin; Lee, Kyoung Ok; Medina, Mario A.; Chu, Youhong; Li, Chuanchang

    2018-06-01

    Differential scanning calorimetry (DSC) analysis is a standard thermal analysis technique used to determine the phase transition temperature, enthalpy, heat of fusion, specific heat and activation energy of phase change materials (PCMs). To determine the appropriate heating rate and sample mass, various DSC measurements were carried out using two kinds of PCMs, namely N-octadecane paraffin and calcium chloride hexahydrate. The variations in phase transition temperature, enthalpy, heat of fusion, specific heat and activation energy were observed within applicable heating rates and sample masses. It was found that the phase transition temperature range increased with increasing heating rate and sample mass; while the heat of fusion varied without any established pattern. The specific heat decreased with the increase of heating rate and sample mass. For accuracy purpose, it is recommended that for PCMs with high thermal conductivity (e.g. hydrated salt) the focus will be on heating rate rather than sample mass.

  6. The influence of speaking rate on nasality in the speech of hearing-impaired individuals.

    PubMed

    Dwyer, Claire H; Robb, Michael P; O'Beirne, Greg A; Gilbert, Harvey R

    2009-10-01

    The purpose of this study was to determine whether deliberate increases in speaking rate would serve to decrease the amount of nasality in the speech of severely hearing-impaired individuals. The participants were 11 severely to profoundly hearing-impaired students, ranging in age from 12 to 19 years (M = 16 years). Each participant provided a baseline speech sample (R1) followed by 3 training sessions during which participants were trained to increase their speaking rate. Following the training sessions, a second speech sample was obtained (R2). Acoustic and perceptual analyses of the speech samples obtained at R1 and R2 were undertaken. The acoustic analysis focused on changes in first (F(1)) and second (F(2)) formant frequency and formant bandwidths. The perceptual analysis involved listener ratings of the speech samples (at R1 and R2) for perceived nasality. Findings indicated a significant increase in speaking rate at R2. In addition, significantly narrower F(2) bandwidth and lower perceptual rating scores of nasality were obtained at R2 across all participants, suggesting a decrease in nasality as speaking rate increases. The nasality demonstrated by hearing-impaired individuals is amenable to change when speaking rate is increased. The influences of speaking rate changes on the perception and production of nasality in hearing-impaired individuals are discussed.

  7. Effect of reactor loading on atomic oxygen concentration as measured by NO chemiluminescence

    NASA Technical Reports Server (NTRS)

    Lerner, N. R.

    1989-01-01

    It has previously been observed that the etch rate of polyethylene samples in the afterglow of an RF discharge in oxygen increases with reactor loading. This enhancement of the etch rate is attributed to reactive gas phase products of the polymer etching. In the present work, emission spectroscopy is employed to examine the species present in the gas phase during etching of polyethylene. In particular, the concentration of atomic oxygen downstream from the polyethylene samples is studied as a function of the reactor loading. It is found that the concentration of atomic oxygen increases as the reactor loading is increased. The increase of etch rate with increased reactor loading is attributed to the increase of atomic oxygen concentration in the vicinity of the sample.

  8. Burning of CP Titanium (Grade 2) in Oxygen-Enriched Atmospheres

    NASA Technical Reports Server (NTRS)

    Stoltzfus, Joel M.; Jeffers, Nathan; Gallus, Timothy D.

    2012-01-01

    The flammability in oxygen-enriched atmospheres of commercially pure (CP) titanium rods as a function of diameter and test gas pressure was determined. Test samples of varying diameters were ignited at the bottom and burned upward in 70% O2/balance N2 and in 99.5+% O2 at various pressures. The burning rate of each ignited sample was determined by observing the apparent regression rate of the melting interface (RRMI) of the burning samples. The burning rate or RRMI increased with decreasing test sample diameter and with increasing test gas pressure and oxygen concentration

  9. Influence of sampling rate on the calculated fidelity of an aircraft simulation

    NASA Technical Reports Server (NTRS)

    Howard, J. C.

    1983-01-01

    One of the factors that influences the fidelity of an aircraft digital simulation is the sampling rate. As the sampling rate is increased, the calculated response of the discrete representation tends to coincide with the response of the corresponding continuous system. Because of computer limitations, however, the sampling rate cannot be increased indefinitely. Moreover, real-time simulation requirements demand that a finite sampling rate be adopted. In view of these restrictions, a study was undertaken to determine the influence of sampling rate on the response characteristics of a simulated aircraft describing short-period oscillations. Changes in the calculated response characteristics of the simulated aircraft degrade the fidelity of the simulation. In the present context, fidelity degradation is defined as the percentage change in those characteristics that have the greatest influence on pilot opinion: short period frequency omega, short period damping ratio zeta, and the product omega zeta. To determine the influence of the sampling period on these characteristics, the equations describing the response of a DC-8 aircraft to elevator control inputs were used. The results indicate that if the sampling period is too large, the fidelity of the simulation can be degraded.

  10. Impact of participant incentives and direct and snowball sampling on survey response rate in an ethnically diverse community: results from a pilot study of physical activity and the built environment.

    PubMed

    Perez, Daniel F; Nie, Jason X; Ardern, Chris I; Radhu, Natasha; Ritvo, Paul

    2013-02-01

    Community-wide efforts to encourage healthy behaviours must respond to the needs of existing neighbourhoods, especially those where low physical activity (PA) is associated with social, economic, and cultural challenges. This study reports on the effect of direct and snowball sampling strategies and financial incentive levels on the response rates of a built environment and PA survey in a predominately urban, low-SES new-immigrant community. Women residing in the Jane-Finch neighbourhood of Toronto, Ontario were selected to participate by quasi-random sampling, yielding a response rate of 41.5%. The survey completion rate per contact attempt increased 2-fold when incentives were increased from $10 to $20 and a further threefold following the increase from $20 to $30. Snowball sampled respondents were older, less likely to have full-time employment, and had lower educational attainment than directly sampled participants. With appropriate incentives, face-to-face contact, and snowball sampling, survey-based research is feasible within a low-SES, high minority population.

  11. Growth, chamber building rate and reproduction time of Palaeonummulites venosus under natural conditions.

    NASA Astrophysics Data System (ADS)

    Kinoshita, Shunichi; Eder, Wolfgang; Wöger, Julia; Hohenegger, Johann; Briguglio, Antonino

    2017-04-01

    Investigations on Palaeonummulites venosus using the natural laboratory approach for determining chamber building rate, test diameter increase rate, reproduction time and longevity is based on the decomposition of monthly obtained frequency distributions based on chamber number and test diameter into normal-distributed components. The shift of the component parameters 'mean' and 'standard deviation' during the investigation period of 15 months was used to calculate Michaelis-Menten functions applied to estimate the averaged chamber building rate and diameter increase rate under natural conditions. The individual dates of birth were estimated using the inverse averaged chamber building rate and the inverse diameter increase rate fitted by the individual chamber number or the individual test diameter at the sampling date. Distributions of frequencies and densities (i.e. frequency divided by sediment weight) based on chamber building rate and diameter increase rate resulted both in a continuous reproduction through the year with two peaks, the stronger in May /June determined as the beginning of the summer generation (generation1) and the weaker in November determined as the beginning of the winter generation (generation 2). This reproduction scheme explains the existence of small and large specimens in the same sample. Longevity, calculated as the maximum difference in days between the individual's birth date and the sampling date seems to be round about one year, obtained by both estimations based on the chamber building rate and the diameter increase rate.

  12. [Method for concentration determination of mineral-oil fog in the air of workplace].

    PubMed

    Xu, Min; Zhang, Yu-Zeng; Liu, Shi-Feng

    2008-05-01

    To study the method of concentration determination of mineral-oil fog in the air of workplace. Four filter films such as synthetic fabric filter film, beta glass fiber filter film, chronic filter paper and microporous film were used in this study. Two kinds of dust samplers were used to collect the sample, one sampling at fast flow rate in a short time and the other sampling at slow flow rate with long duration. Subsequently, the filter membrane was weighed with electronic analytical balance. According to sampling efficiency and incremental size, the adsorbent ability of four different filter membranes was compared. When the flow rate was between 10 approximately 20 L/min and the sampling time was between 10 approximately 15 min, the average sampling efficiency of synthetic fabric filter film was 95.61% and the increased weight ranged from 0.87 to 2.60 mg. When the flow rate was between 10 approximately 20 L/min and sampling time was between 10 approximately 15 min, the average sampling efficiency of beta glass fiber filter film was 97.57% and the increased weight was 0.75 approximately 2.47 mg. When the flow rate was between 5 approximately 10 L/min and the sampling time between 10 approximately 20 min, the average sampling efficiency of chronic filter paper and microporous film was 48.94% and 63.15%, respectively and the increased weight was 0.75 approximately 2.15 mg and 0.23 approximately 0.85 mg, respectively. When the flow rate was 3.5 L/min and the sampling time was between 100 approximately 166 min, the average sampling efficiency of filter film were 94.44% and 93.45%, respectively and the average increased weight was 1.28 mg for beta glass fiber filter film and 0.78 mg for beta glass fiber filter film and synthetic fabric synthetic fabric filter film. The average sampling efficiency of chronic filter paper and microporous film were 37.65% and 88.21%, respectively. The average increased weight was 4.30 mg and 1.23 mg, respectively. Sampling with synthetic fabric filter film and beta glass fiber filter film is credible, accurate, simple and feasible for determination of the concentration of mineral-oil fog in workplaces.

  13. The effect of branding on consumer palatability ratings of beef strip loin steaks.

    PubMed

    Wilfong, A K; McKillip, K V; Gonzalez, J M; Houser, T A; Unruh, J A; Boyle, E A E; O'Quinn, T G

    2016-11-01

    The objective of this study was to determine the influence of knowing the brand or USDA grade on consumer palatability ratings of beef strip loin steaks. Strip loins were selected to represent 5 USDA grades and brands, USDA Select, Choice, Prime, Certified Angus Beef (CAB; upper 2/3 Choice), and Select, from carcasses of cattle classified as Angus on the basis of phenotype. After 21 d of aging, 2.5-cm-thick steaks were cut, consecutively cut steaks were paired for consumer evaluation. Consumer panelists ( = 112) evaluated samples for tenderness, juiciness, flavor liking, and overall liking. Additionally, consumers rated each palatability trait as either acceptable or unacceptable. Samples were fed in 2 rounds on the same day: blind and informed testing. In the first round, blind testing, consumers were served 1 sample from each treatment, with no product information provided. In the second round, consumers were informed of the brand or quality grade prior to sampling. During blind testing, CAB rated similar ( > 0.05) to Choice for all palatability traits; however, CAB rated greater ( < 0.05) than Choice for all traits during informed testing. Additionally, Angus Select and Select were rated similar > 0.05) for all traits when tested blind, but Angus Select was rated greater ( < 0.05) than Select for flavor and overall liking when brand was declared. When comparing blind and informed ratings, Angus Select and CAB had greater ( < 0.05) ratings for juiciness, flavor liking, and overall liking, and Prime had increased ( < 0.05) ratings for flavor liking and overall liking because of brand disclosure. However, ratings for Choice and Select samples were unaffected ( > 0.05) when brand was disclosed. Brand knowledge increased ( < 0.05) the percentage of Prime samples rated as acceptable for flavor and the percentage of Angus Select samples rated as acceptable for flavor and overall liking. Conversely, there was no difference ( > 0.05) in the percentage of Choice and Select samples rated as acceptable for all palatability traits. These data indicate that Prime, CAB, and Angus Select steaks receive an increase in consumer palatability perception, or "brand lift," which does not occur for Choice and Select beef.

  14. Stability and bias of classification rates in biological applications of discriminant analysis

    USGS Publications Warehouse

    Williams, B.K.; Titus, K.; Hines, J.E.

    1990-01-01

    We assessed the sampling stability of classification rates in discriminant analysis by using a factorial design with factors for multivariate dimensionality, dispersion structure, configuration of group means, and sample size. A total of 32,400 discriminant analyses were conducted, based on data from simulated populations with appropriate underlying statistical distributions. Simulation results indicated strong bias in correct classification rates when group sample sizes were small and when overlap among groups was high. We also found that stability of the correct classification rates was influenced by these factors, indicating that the number of samples required for a given level of precision increases with the amount of overlap among groups. In a review of 60 published studies, we found that 57% of the articles presented results on classification rates, though few of them mentioned potential biases in their results. Wildlife researchers should choose the total number of samples per group to be at least 2 times the number of variables to be measured when overlap among groups is low. Substantially more samples are required as the overlap among groups increases

  15. Effect of cooling rates on the structure, density and micro-indentation behavior of the Fe, Co-based bulk metallic glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lesz, Sabina, E-mail: sabina.lesz@polsl.pl

    The experiments demonstrate that ductility of the samples of bulk metallic glass (BMG) with the same chemical composition increased with decreasing sample size. It is shown that microhardness and density increases with decreasing the cooling rate. The fracture morphology of rods after compressive fracture were different on the cross section. Two characteristic features of the compressive fracture morphologies of metallic glasses (MGs) were observed in samples: smooth region and the vein pattern. Many parallel shear bands were observed on the deformed specimen with ϕ = 2 mm in diameter. The results provide more understanding on the relationship among the coolingmore » rate, structure and micro-indentation behavior of the Fe-Co-based BMGs. - Highlights: •Fracture morphology and micro-indentation behavior is studied. •The smaller BMG sample exhibits the larger plasticity. •Microhardness and density increase with decreasing the cooling rate. •Formation of shear bands has been reported in deformed specimens. •Structure and mechanical properties of BMGs can be controlled by the cooling rate.« less

  16. Sampling studies to estimate the HIV prevalence rate in female commercial sex workers.

    PubMed

    Pascom, Ana Roberta Pati; Szwarcwald, Célia Landmann; Barbosa Júnior, Aristides

    2010-01-01

    We investigated sampling methods being used to estimate the HIV prevalence rate among female commercial sex workers. The studies were classified according to the adequacy or not of the sample size to estimate HIV prevalence rate and according to the sampling method (probabilistic or convenience). We identified 75 studies that estimated the HIV prevalence rate among female sex workers. Most of the studies employed convenience samples. The sample size was not adequate to estimate HIV prevalence rate in 35 studies. The use of convenience sample limits statistical inference for the whole group. It was observed that there was an increase in the number of published studies since 2005, as well as in the number of studies that used probabilistic samples. This represents a large advance in the monitoring of risk behavior practices and HIV prevalence rate in this group.

  17. A Critical Assessment of Bias in Survey Studies Using Location-Based Sampling to Recruit Patrons in Bars

    PubMed Central

    Morrison, Christopher; Lee, Juliet P.; Gruenewald, Paul J.; Marzell, Miesha

    2015-01-01

    Location-based sampling is a method to obtain samples of people within ecological contexts relevant to specific public health outcomes. Random selection increases generalizability, however in some circumstances (such as surveying bar patrons) recruitment conditions increase risks of sample bias. We attempted to recruit representative samples of bars and patrons in six California cities, but low response rates precluded meaningful analysis. A systematic review of 24 similar studies revealed that none addressed the key shortcomings of our study. We recommend steps to improve studies that use location-based sampling: (i) purposively sample places of interest, (ii) utilize recruitment strategies appropriate to the environment, and (iii) provide full information on response rates at all levels of sampling. PMID:26574657

  18. Improvement of Gynecological Screening of Female Renal Transplant Recipients by Self-Sampling for Human Papillomavirus Detection.

    PubMed

    Hinten, Floor; Hilbrands, Luuk B; Meeuwis, Kim A; van Bergen-Verkuyten, Muriël C; Slangen, Brigitte F; van Rossum, Michelle M; Rahamat-Langendoen, Janette; Massuger, Leon F; de Hullu, Joanne A; Melchers, Willem J

    2017-01-01

    Female renal transplant recipients (RTRs) have increased risk for developing human papillomavirus (HPV)-related (pre)malignancies of the lower genital tract. Annual cervical screening is advised for RTRs, but the participation rate is low. The aim of this study is to investigate whether HPV self-sampling is suitable for gynecological screening of RTRs to increase participation rate. A large cohort of 253 RTRs was investigated for the prevalence of HPV. All participants received a device for a cervicovaginal self-sample. Questionnaires were sent to assess the experience with this device. High-risk (hrHPV) presence was determined with the SPF10-LiPA25 system and GP5+/6+ PCR. HrHPV-positive patients underwent gynecological examination. More than 90% of the patients rated their experience with the self-sample device as good to excellent, and 77% preferred self-sampling over a physician taken sample. Approximately thirty-five of 217 women tested hrHPV positive with SPF10- LiPA25, and 22 tested positive with the GP5+/6+ PCR. Eleven hrHPV-positive patients had clinically relevant gynecological abnormalities, and they all tested positive with GP5+/6+ PCR. Self-sampling is clinically applicable in a gynecological screening and is preferred by female RTRs. Therefore, self-sampling could be implemented with the aim to increase the participation rate of female RTRs in yearly gynecological screening.

  19. Optimization of pulsed DC PACVD parameters: Toward reducing wear rate of the DLC films

    NASA Astrophysics Data System (ADS)

    Ebrahimi, Mansoureh; Mahboubi, Farzad; Naimi-Jamal, M. Reza

    2016-12-01

    The effect of pulsed direct current (DC) plasma-assisted chemical vapor deposition (PACVD) parameters such as temperature, duty cycle, hydrogen flow, and argon/CH4 flow ratio on the wear behavior and wear durability of the diamond-like carbon (DLC) films was studied by using response surface methodology (RSM). DLC films were deposited on nitrocarburized AISI 4140 steel. Wear rate and wear durability of the DLC films were examined with the pin-on-disk method. Field emission scanning electron microscopy, Raman spectroscopy, and nanoindentation techniques were used for studying wear mechanisms, chemical structure, and hardness of the DLC films. RSM results show that duty cycle is one of the important parameters that affect the wear rate of the DLC samples. The wear rate of the samples deposited with a duty cycle of >75% decreases with an increase in the argon/CH4 ratio. In contrast, for a duty cycle of <65%, the wear rate increases with an increase in the argon/CH4 ratio. The wear durability of the DLC samples increases with an increase in the duty cycle, hydrogen flow, and argon/CH4 flow ratio at the deposition temperature between 85 °C and 110 °C. Oxidation, fatigue, abrasive wear, and graphitization are the wear mechanisms observed on the wear scar of the DLC samples deposited with the optimum deposition conditions.

  20. THE EFFECT OF RATE OF GLAND FUNCTION ON PAROTID FLUID URIC ACID LEVELS.

    DTIC Science & Technology

    Paired parotid fluid samples were collected without exogenous stimulation and at 5 different gustation-induced rates of flow. Enzymatic uric acid...diminished as flow rate increased. It is suggested that parotid fluid samples for uric acid analysis should be collected at flow rates of 0.7 ml./min. or more. (Author)

  1. Oxidation kinetics of hydride-bearing uranium metal corrosion products

    NASA Astrophysics Data System (ADS)

    Totemeier, Terry C.; Pahl, Robert G.; Frank, Steven M.

    The oxidation behavior of hydride-bearing uranium metal corrosion products from Zero Power Physics Reactor (ZPPR) fuel plates was studied using thermo-gravimetric analysis (TGA) in environments of Ar-4%O 2, Ar-9%O 2, and Ar-20%O 2. Ignition of corrosion product samples from two moderately corroded plates was observed between 125°C and 150°C in all environments. The rate of oxidation above the ignition temperature was found to be dependent only on the net flow rate of oxygen in the reacting gas. Due to the higher net oxygen flow rate, burning rates increased with increasing oxygen concentration. Oxidation rates below the ignition temperature were much slower and decreased with increasing test time. The hydride contents of the TGA samples from the two moderately corroded plates, determined from the total weight gain achieved during burning, were 47-61 wt% and 29-39 wt%. Samples from a lightly corroded plate were not reactive; X-ray diffraction (XRD) confirmed that they contained little hydride.

  2. 77 FR 22463 - Importation of Clementines From Spain; Amendment to Inspection Provisions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-16

    ... adjust the sampling rate and thereby detect pests that might otherwise go undetected prior to treatment... distribution. The commenter recommended that, for those reasons, 200 fruit per consignment be the minimum... concern that an increase in the sampling rate would require more time for APHIS inspectors to sample the...

  3. The comparative effectiveness of fine-needle aspiration cytology sampling policies: a simulation study.

    PubMed

    Schmidt, Robert L; Howard, Kirsten; Hall, Brian J; Layfield, Lester J

    2012-12-01

    Sample adequacy is an important aspect of overall fine-needle aspiration cytology (FNAC) performance. FNAC effectiveness is augmented by an increasing number of needle passes, but increased needle passes are associated with higher costs and greater risk of adverse events. The objective of this study was to compare the impact of several different sampling policies on FNAC effectiveness and adverse event rates using discrete event simulation. We compared 8 different sampling policies in 12 different sampling environments. All sampling policies were effective when the per-pass accuracy is high (>80%). Rapid on-site evaluation (ROSE) improves FNAC effectiveness when the per-pass adequacy rate is low. ROSE is unlikely to be cost-effective in sampling environments in which the per-pass adequacy is high. Alternative ROSE assessors (eg, cytotechnologists) may be a cost-effective alternative to pathologists when the per-pass adequacy rate is moderate (60%-80%) or when the number of needle passes is limited.

  4. Proposing an Empirically Justified Reference Threshold for Blood Culture Sampling Rates in Intensive Care Units

    PubMed Central

    Castell, Stefanie; Schwab, Frank; Geffers, Christine; Bongartz, Hannah; Brunkhorst, Frank M.; Gastmeier, Petra; Mikolajczyk, Rafael T.

    2014-01-01

    Early and appropriate blood culture sampling is recommended as a standard of care for patients with suspected bloodstream infections (BSI) but is rarely taken into account when quality indicators for BSI are evaluated. To date, sampling of about 100 to 200 blood culture sets per 1,000 patient-days is recommended as the target range for blood culture rates. However, the empirical basis of this recommendation is not clear. The aim of the current study was to analyze the association between blood culture rates and observed BSI rates and to derive a reference threshold for blood culture rates in intensive care units (ICUs). This study is based on data from 223 ICUs taking part in the German hospital infection surveillance system. We applied locally weighted regression and segmented Poisson regression to assess the association between blood culture rates and BSI rates. Below 80 to 90 blood culture sets per 1,000 patient-days, observed BSI rates increased with increasing blood culture rates, while there was no further increase above this threshold. Segmented Poisson regression located the threshold at 87 (95% confidence interval, 54 to 120) blood culture sets per 1,000 patient-days. Only one-third of the investigated ICUs displayed blood culture rates above this threshold. We provided empirical justification for a blood culture target threshold in ICUs. In the majority of the studied ICUs, blood culture sampling rates were below this threshold. This suggests that a substantial fraction of BSI cases might remain undetected; reporting observed BSI rates as a quality indicator without sufficiently high blood culture rates might be misleading. PMID:25520442

  5. Temperature effect on mechanical and tribological characterization of Mg-SiC nanocomposite fabricated by high rate compaction

    NASA Astrophysics Data System (ADS)

    Majzoobi, G. H.; Rahmani, K.; Atrian, A.

    2018-01-01

    In this paper, dynamic compaction is employed to produce Mg-SiC nanocomposite samples using a mechanical drop hammer. Different volume fractions of SiC nano reinforcement and magnesium (Mg) micron-size powder as the matrix are mechanically milled and consolidated at different temperatures. It is found that with the increase of temperature the sintering requirements is satisfied and higher quality samples are fabricated. The density, hardness, compressive strength and the wear resistance of the compacted specimens are characterized in this work. It was found that by increasing the content of nano reinforcement, the relative density of the compacted samples decreases, whereas, the micro-hardness and the strength of the samples enhance. Furthermore, higher densification temperatures lead to density increase and hardness reduction. Additionally, it is found that the wear rate of the nanocomposite is increased remarkably by increasing the SiC nano reinforcement.

  6. The influence of taxon sampling on Bayesian divergence time inference under scenarios of rate heterogeneity among lineages.

    PubMed

    Soares, André E R; Schrago, Carlos G

    2015-01-07

    Although taxon sampling is commonly considered an important issue in phylogenetic inference, it is rarely considered in the Bayesian estimation of divergence times. In fact, the studies conducted to date have presented ambiguous results, and the relevance of taxon sampling for molecular dating remains unclear. In this study, we developed a series of simulations that, after six hundred Bayesian molecular dating analyses, allowed us to evaluate the impact of taxon sampling on chronological estimates under three scenarios of among-lineage rate heterogeneity. The first scenario allowed us to examine the influence of the number of terminals on the age estimates based on a strict molecular clock. The second scenario imposed an extreme example of lineage specific rate variation, and the third scenario permitted extensive rate variation distributed along the branches. We also analyzed empirical data on selected mitochondrial genomes of mammals. Our results showed that in the strict molecular-clock scenario (Case I), taxon sampling had a minor impact on the accuracy of the time estimates, although the precision of the estimates was greater with an increased number of terminals. The effect was similar in the scenario (Case III) based on rate variation distributed among the branches. Only under intensive rate variation among lineages (Case II) taxon sampling did result in biased estimates. The results of an empirical analysis corroborated the simulation findings. We demonstrate that taxonomic sampling affected divergence time inference but that its impact was significant if the rates deviated from those derived for the strict molecular clock. Increased taxon sampling improved the precision and accuracy of the divergence time estimates, but the impact on precision is more relevant. On average, biased estimates were obtained only if lineage rate variation was pronounced. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Is 50 Hz high enough ECG sampling frequency for accurate HRV analysis?

    PubMed

    Mahdiani, Shadi; Jeyhani, Vala; Peltokangas, Mikko; Vehkaoja, Antti

    2015-01-01

    With the worldwide growth of mobile wireless technologies, healthcare services can be provided at anytime and anywhere. Usage of wearable wireless physiological monitoring system has been extensively increasing during the last decade. These mobile devices can continuously measure e.g. the heart activity and wirelessly transfer the data to the mobile phone of the patient. One of the significant restrictions for these devices is usage of energy, which leads to requiring low sampling rate. This article is presented in order to investigate the lowest adequate sampling frequency of ECG signal, for achieving accurate enough time domain heart rate variability (HRV) parameters. For this purpose the ECG signals originally measured with high 5 kHz sampling rate were down-sampled to simulate the measurement with lower sampling rate. Down-sampling loses information, decreases temporal accuracy, which was then restored by interpolating the signals to their original sampling rates. The HRV parameters obtained from the ECG signals with lower sampling rates were compared. The results represent that even when the sampling rate of ECG signal is equal to 50 Hz, the HRV parameters are almost accurate with a reasonable error.

  8. Annealing to optimize the primary drying rate, reduce freezing-induced drying rate heterogeneity, and determine T(g)' in pharmaceutical lyophilization.

    PubMed

    Searles, J A; Carpenter, J F; Randolph, T W

    2001-07-01

    In a companion paper we show that the freezing of samples in vials by shelf-ramp freezing results in significant primary drying rate heterogeneity because of a dependence of the ice crystal size on the nucleation temperature during freezing.1 The purpose of this study was to test the hypothesis that post-freezing annealing, in which the product is held at a predetermined temperature for a specified duration, can reduce freezing-induced heterogeneity in sublimation rates. In addition, we test the impact of annealing on primary drying rates. Finally, we use the kinetics of relaxations during annealing to provide a simple measurement of T(g)', the glass transition temperature of the maximally freeze-concentrated amorphous phase, under conditions and time scales most appropriate for industrial lyophilization cycles. Aqueous solutions of hydroxyethyl starch (HES), sucrose, and HES:sucrose were either frozen by placement on a shelf while the temperature was reduced ("shelf-ramp frozen") or by immersion into liquid nitrogen. Samples were then annealed for various durations over a range of temperatures and partially lyophilized to determine the primary drying rate. The morphology of fully dried liquid nitrogen-frozen samples was examined using scanning electron microscopy. Annealing reduced primary drying rate heterogeneity for shelf-ramp frozen samples, and resulted in up to 3.5-fold increases in the primary drying rate. These effects were due to increased ice crystal sizes, simplified amorphous structures, and larger and more numerous holes on the cake surface of annealed samples. Annealed HES samples dissolved slightly faster than their unannealed counterparts. Annealing below T(g)' did not result in increased drying rates. We present a simple new annealing-lyophilization method of T(g)' determination that exploits this phenomenon. It can be carried out with a balance and a freeze-dryer, and has the additional advantage that a large number of candidate formulations can be evaluated simultaneously.

  9. Self-Sampling for Human Papillomavirus Testing among Non-Attenders Increases Attendance to the Norwegian Cervical Cancer Screening Programme

    PubMed Central

    Enerly, Espen; Bonde, Jesper; Schee, Kristina; Pedersen, Helle; Lönnberg, Stefan; Nygård, Mari

    2016-01-01

    Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV) testing as an alternative to a clinical sampling can be a useful policy to increase attendance. To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP), 800 women aged 25–69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited to be part of the intervention group. Women in this group received one of two self-sampling devices, Evalyn Brush or Delphi Screener. To attend screening, women in the intervention group had the option of using the self-sampling device (self-sampling subgroup) or visiting their physician for a cervical smear. Self-sampled specimens were split and analyzed for the presence of high-risk (hr) HPV by the CLART® HPV2 test and the digene® Hybrid Capture (HC)2 test. The control group consisted of 2593 women who received a 2nd reminder letter according to the current guidelines of the NCCSP. The attendance rates were 33.4% in the intervention group and 23.2% in the control group, with similar attendance rates for both self-sampling devices. Women in the self-sampling subgroup responded favorably to both self-sampling devices and cited not remembering receiving a call for screening as the most dominant reason for previous non-attendance. Thirty-two of 34 (94.1%) hrHPV-positive women in the self-sampling subgroup attended follow-up. In conclusion, self-sampling increased attendance rates and was feasible and well received. This study lends further support to the proposal that self-sampling may be a valuable alternative for increasing cervical cancer screening coverage in Norway. PMID:27073929

  10. Self-Sampling for Human Papillomavirus Testing among Non-Attenders Increases Attendance to the Norwegian Cervical Cancer Screening Programme.

    PubMed

    Enerly, Espen; Bonde, Jesper; Schee, Kristina; Pedersen, Helle; Lönnberg, Stefan; Nygård, Mari

    2016-01-01

    Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV) testing as an alternative to a clinical sampling can be a useful policy to increase attendance. To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP), 800 women aged 25-69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited to be part of the intervention group. Women in this group received one of two self-sampling devices, Evalyn Brush or Delphi Screener. To attend screening, women in the intervention group had the option of using the self-sampling device (self-sampling subgroup) or visiting their physician for a cervical smear. Self-sampled specimens were split and analyzed for the presence of high-risk (hr) HPV by the CLART® HPV2 test and the digene® Hybrid Capture (HC)2 test. The control group consisted of 2593 women who received a 2nd reminder letter according to the current guidelines of the NCCSP. The attendance rates were 33.4% in the intervention group and 23.2% in the control group, with similar attendance rates for both self-sampling devices. Women in the self-sampling subgroup responded favorably to both self-sampling devices and cited not remembering receiving a call for screening as the most dominant reason for previous non-attendance. Thirty-two of 34 (94.1%) hrHPV-positive women in the self-sampling subgroup attended follow-up. In conclusion, self-sampling increased attendance rates and was feasible and well received. This study lends further support to the proposal that self-sampling may be a valuable alternative for increasing cervical cancer screening coverage in Norway.

  11. A quantitative evaluation of two methods for preserving hair samples

    USGS Publications Warehouse

    Roon, David A.; Waits, L.P.; Kendall, K.C.

    2003-01-01

    Hair samples are an increasingly important DNA source for wildlife studies, yet optimal storage methods and DNA degradation rates have not been rigorously evaluated. We tested amplification success rates over a one-year storage period for DNA extracted from brown bear (Ursus arctos) hair samples preserved using silica desiccation and -20C freezing. For three nuclear DNA microsatellites, success rates decreased significantly after a six-month time point, regardless of storage method. For a 1000 bp mitochondrial fragment, a similar decrease occurred after a two-week time point. Minimizing delays between collection and DNA extraction will maximize success rates for hair-based noninvasive genetic sampling projects.

  12. Effect of dissolved organic matter on pre-equilibrium passive sampling: A predictive QSAR modeling study.

    PubMed

    Lin, Wei; Jiang, Ruifen; Shen, Yong; Xiong, Yaxin; Hu, Sizi; Xu, Jianqiao; Ouyang, Gangfeng

    2018-04-13

    Pre-equilibrium passive sampling is a simple and promising technique for studying sampling kinetics, which is crucial to determine the distribution, transfer and fate of hydrophobic organic compounds (HOCs) in environmental water and organisms. Environmental water samples contain complex matrices that complicate the traditional calibration process for obtaining the accurate rate constants. This study proposed a QSAR model to predict the sampling rate constants of HOCs (polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and pesticides) in aqueous systems containing complex matrices. A homemade flow-through system was established to simulate an actual aqueous environment containing dissolved organic matter (DOM) i.e. humic acid (HA) and (2-Hydroxypropyl)-β-cyclodextrin (β-HPCD)), and to obtain the experimental rate constants. Then, a quantitative structure-activity relationship (QSAR) model using Genetic Algorithm-Multiple Linear Regression (GA-MLR) was found to correlate the experimental rate constants to the system state including physicochemical parameters of the HOCs and DOM which were calculated and selected as descriptors by Density Functional Theory (DFT) and Chem 3D. The experimental results showed that the rate constants significantly increased as the concentration of DOM increased, and the enhancement factors of 70-fold and 34-fold were observed for the HOCs in HA and β-HPCD, respectively. The established QSAR model was validated as credible (R Adj. 2 =0.862) and predictable (Q 2 =0.835) in estimating the rate constants of HOCs for complex aqueous sampling, and a probable mechanism was developed by comparison to the reported theoretical study. The present study established a QSAR model of passive sampling rate constants and calibrated the effect of DOM on the sampling kinetics. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Polyurethane foam (PUF) disks passive air samplers: wind effect on sampling rates.

    PubMed

    Tuduri, Ludovic; Harner, Tom; Hung, Hayley

    2006-11-01

    Different passive sampler housings were evaluated for their wind dampening ability and how this might translate to variability in sampler uptake rates. Polyurethane foam (PUF) disk samplers were used as the sampling medium and were exposed to a PCB-contaminated atmosphere in a wind tunnel. The effect of outside wind speed on PUF disk sampling rates was evaluated by exposing polyurethane foam (PUF) disks to a PCB-contaminated air stream in a wind tunnel over air velocities in the range 0 to 1.75 m s-1. PUF disk sampling rates increased gradually over the range 0-0.9 m s-1 at approximately 4.5-14.6 m3 d-1 and then increased sharply to approximately 42 m3 d-1 at approximately 1.75 m s-1 (sum of PCBs). The results indicate that for most field deployments the conventional 'flying saucer' housing adequately dampens the wind effect and will yield approximately time-weighted air concentrations.

  14. Pre-Survey Text Messages (SMS) Improve Participation Rate in an Australian Mobile Telephone Survey: An Experimental Study.

    PubMed

    Dal Grande, Eleonora; Chittleborough, Catherine Ruth; Campostrini, Stefano; Dollard, Maureen; Taylor, Anne Winifred

    2016-01-01

    Mobile telephone numbers are increasingly being included in household surveys samples. As approach letters cannot be sent because many do not have address details, alternatives approaches have been considered. This study assesses the effectiveness of sending a short message service (SMS) to a random sample of mobile telephone numbers to increase response rates. A simple random sample of 9000 Australian mobile telephone numbers: 4500 were randomly assigned to be sent a pre-notification SMS, and the remaining 4500 did not have a SMS sent. Adults aged 18 years and over, and currently in paid employment, were eligible to participate. American Association for Public Opinion Research formulas were used to calculated response cooperation and refusal rates. Response and cooperation rate were higher for the SMS groups (12.4% and 28.6% respectively) than the group with no SMS (7.7% and 16.0%). Refusal rates were lower for the SMS group (27.3%) than the group with no SMS (35.9%). When asked, 85.8% of the pre-notification group indicated they remembered receiving a SMS about the study. Sending a pre-notification SMS is effective in improving participation in population-based surveys. Response rates were increased by 60% and cooperation rates by 79%.

  15. Compositional investigation of ∼2 μm luminescence of Ho{sup 3+}-doped lead silicate glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Xueqiang; Huang, Feifei; Gao, Song

    2015-11-15

    Graphical abstract: Ho{sup 3+}-doped lead silicate glass with lowest maximum phonon energy possesses highest ∼2 μm luminescence intensity. - Highlights: • With increment of lead oxide, maximum phonon energy in lead silicate glass decreased. • ∼2 μm luminescent intensity of Ho{sup 3+} increased with increment of lead oxide. • Lowest lead oxide content glass possesses highest quantum efficiency due to low maximum phonon energy. - Abstract: Lead silicate glass samples with varying lead oxide content were prepared in this study, and their luminescent properties were examined and analyzed. It was found that with increasing lead oxide content, the maximum phononmore » energies of the glass samples decreased, while their spontaneous transition probabilities first increased and then decreased. The influence of the spontaneous transition rate, A{sub 10}, and the multi-phonon relaxation rate, W{sub 10}, on the sample luminescent properties was analyzed using rate equations. As a result, it was found that with increasing lead oxide content, W{sub 10}/A{sub 10} decreased, while the quantum efficiency increased. Thus, the luminescent intensity at ∼2 μm increased in the glass samples with increased lead oxide content. The high luminescent intensity and long lifetime indicate that silicate glasses containing high levels of lead oxide could potentially be used in ∼2 μm lasers.« less

  16. Dependence of Tritium Release from Stainless Steel on Temperature and Water Vapor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shmayda, W. T.; Sharpe, M.; Boyce, A. M.

    The impact of water vapor and temperature on the release of tritium from stainless steel was studied. Degreased stainless steel samples loaded with tritium at room temperature following a 24-h degassing in vacuum at room temperature were subjected to increasing temperatures or humidity. In general, increasing either the sample temperature or the humidity causes an increased quantity of tritium to be removed. Increasing the temperature to 300°C in a dry gas stream results in a significant release of tritium and is therefore an effective means for reducing the tritium inventory in steel. For humid purges at 30°C, a sixfold increasemore » in humidity results in a tenfold increase in the peak outgassing rate. Increasing the humidity from 4 parts per million (ppm) to 1000 ppm when the sample temperature is 100°C causes a significant increase in the tritium outgassing rate. Finally, a simple calculation shows that only 15% of the activity present in the sample was removed in these experiments, suggesting that the surface layer of adsorbed water participates in regulating tritium desorption from the surface.« less

  17. Dependence of Tritium Release from Stainless Steel on Temperature and Water Vapor

    DOE PAGES

    Shmayda, W. T.; Sharpe, M.; Boyce, A. M.; ...

    2015-09-15

    The impact of water vapor and temperature on the release of tritium from stainless steel was studied. Degreased stainless steel samples loaded with tritium at room temperature following a 24-h degassing in vacuum at room temperature were subjected to increasing temperatures or humidity. In general, increasing either the sample temperature or the humidity causes an increased quantity of tritium to be removed. Increasing the temperature to 300°C in a dry gas stream results in a significant release of tritium and is therefore an effective means for reducing the tritium inventory in steel. For humid purges at 30°C, a sixfold increasemore » in humidity results in a tenfold increase in the peak outgassing rate. Increasing the humidity from 4 parts per million (ppm) to 1000 ppm when the sample temperature is 100°C causes a significant increase in the tritium outgassing rate. Finally, a simple calculation shows that only 15% of the activity present in the sample was removed in these experiments, suggesting that the surface layer of adsorbed water participates in regulating tritium desorption from the surface.« less

  18. Twenty-year trends of authorship and sampling in applied biomechanics research.

    PubMed

    Knudson, Duane

    2012-02-01

    This study documented the trends in authorship and sampling in applied biomechanics research published in the Journal of Applied Biomechanics and ISBS Proceedings. Original research articles of the 1989, 1994, 1999, 2004, and 2009 volumes of these serials were reviewed, excluding reviews, modeling papers, technical notes, and editorials. Compared to 1989 volumes, the mean number of authors per paper significantly increased (35 and 100%, respectively) in the 2009 volumes, along with increased rates of hyperauthorship, and a decline in rates of single authorship. Sample sizes varied widely across papers and did not appear to change since 1989.

  19. Direct measurements of sample heating by a laser-induced air plasma in pre-ablation spark dual-pulse laser-induced breakdown spectroscopy (LIBS).

    PubMed

    Register, Janna; Scaffidi, Jonathan; Angel, S Michael

    2012-08-01

    Direct measurements of temperature changes were made using small thermocouples (TC), placed near a laser-induced air plasma. Temperature changes up to ~500 °C were observed. From the measured temperature changes, estimates were made of the amount of heat absorbed per unit area. This allowed calculations to be made of the surface temperature, as a function of time, of a sample heated by the air plasma that is generated during orthogonal pre-ablation spark dual-pulse (DP) LIBS measurements. In separate experiments, single-pulse (SP) LIBS emission and sample ablation rate measurements were performed on nickel at sample temperatures ranging from room temperature to the maximum surface temperature that was calculated using the TC measurement results (500 °C). A small, but real sample temperature-dependent increase in both SP LIBS emission and the rate of sample ablation was found for nickel samples heated up to 500 °C. Comparison of DP LIBS emission enhancement values for bulk nickel samples at room temperature versus the enhanced SP LIBS emission and sample ablation rates observed as a function of increasing sample temperature suggests that sample heating by the laser-induced air plasma plays only a minor role in DP LIBS emission enhancement.

  20. C-Arm Computed Tomography-Assisted Adrenal Venous Sampling Improved Right Adrenal Vein Cannulation and Sampling Quality in Primary Aldosteronism.

    PubMed

    Park, Chung Hyun; Hong, Namki; Han, Kichang; Kang, Sang Wook; Lee, Cho Rok; Park, Sungha; Rhee, Yumie

    2018-05-04

    Adrenal venous sampling (AVS) is a gold standard for subtype classification of primary aldosteronism (PA). However, this procedure has a high failure rate because of the anatomical difficulties in accessing the right adrenal vein. We investigated whether C-arm computed tomography-assisted AVS (C-AVS) could improve the success rate of adrenal sampling. A total of 156 patients, diagnosed with PA who underwent AVS from May 2004 through April 2017, were included. Based on the medical records, we retrospectively compared the overall, left, and right catheterization success rates of adrenal veins during the periods without C-AVS (2004 to 2010, n=32) and with C-AVS (2011 to 2016, n=134). The primary outcome was adequate bilateral sampling defined as a selectivity index (SI) >5. With C-AVS, the rates of adequate bilateral AVS increased from 40.6% to 88.7% (P<0.001), with substantial decreases in failure rates (43.7% to 0.8%, P<0.001). There were significant increases in adequate sampling rates from right (43.7% to 91.9%, P<0.001) and left adrenal veins (53.1% to 95.9%, P<0.001) as well as decreases in catheterization failure from right adrenal vein (9.3% to 0.0%, P<0.001). Net improvement of SI on right side remained significant after adjustment for left side (adjusted SI, 1.1 to 9.0; P=0.038). C-AVS was an independent predictor of adequate bilateral sampling in the multivariate model (odds ratio, 9.01; P<0.001). C-AVS improved the overall success rate of AVS, possibly as a result of better catheterization of right adrenal vein. Copyright © 2018 Korean Endocrine Society.

  1. Effect of process conditions on the steam reforming of ethanol with a nano-Ni/SiO2 catalyst.

    PubMed

    Wu, C; Williams, P T

    2012-01-01

    In this paper, a nano-Ni/SiO2 catalyst was prepared by a sol-gel method and tested for hydrogen production from ethanol steam reforming using a two-stage fixed-bed reaction system. The reaction conditions, such as reaction temperature, water/ethanol ratio and sample feeding rate, were investigated with the prepared nano-Ni/SiO2 catalyst. Brunauer-Emmett-Teller surface area and porosity, temperature-programmed oxidation, X-ray diffraction and focused ion beam (FIB)/scanning electron microscopy were used in this work to analysis the fresh and/or reacted catalysts. An extended catalyst stability test for ethanol steam reforming with the Ni/SiO2 catalyst was carried out at a reaction temperature of 600 degrees C, when the water/ethanol ratio was kept at 3.5 and sample feeding rate was 4.74 g h(-1). The results showed that a stabilized gas and hydrogen production was obtained with a potential H2 production of about 40 wt.%. Increasing the reaction temperature during ethanol steam reforming with the Ni/SiO2 catalyst resulted in an increase of gas and hydrogen production. The gas yield was slightly reduced when the water/ethanol ratio was increased from 2.0 to 3.5. However, the potential H2 production was increased. The investigation of the sample feeding rate showed that the gas production per hour was increased due to the higher sample feeding rate, but the potential H2 production was reduced.

  2. Microbiopsies versus Bergström needle for skeletal muscle sampling: impact on maximal mitochondrial respiration rate.

    PubMed

    Isner-Horobeti, M E; Charton, A; Daussin, F; Geny, B; Dufour, S P; Richard, R

    2014-05-01

    Microbiopsies are increasingly used as an alternative to the standard Bergström technique for skeletal muscle sampling. The potential impact of these two different procedures on mitochondrial respiration rate is unknown. The objective of this work was to compare microbiopsies versus Bergström procedure on mitochondrial respiration in skeletal muscle. 52 vastus lateralis muscle samples were obtained from 13 anesthetized pigs, either with a Bergström [6 gauges (G)] needle or with microbiopsy needles (12, 14, 18G). Maximal mitochondrial respiration (V GM-ADP) was assessed using an oxygraphic method on permeabilized fibers. The weight of the muscle samples and V GM-ADP decreased with the increasing gauge of the needles. A positive nonlinear relationship was observed between the weight of the muscle sample and the level of maximal mitochondrial respiration (r = 0.99, p < 0.05) and between needle size and maximal mitochondrial respiration (r = 0.99, p < 0.05). Microbiopsies give lower muscle sample weight and maximal rate of mitochondrial respiration compared to the standard Bergström needle.Therefore, the higher the gauge (i.e. the smaller the size) of the microbiopsy needle, the lower is the maximal rate of respiration. Microbiopsies of skeletal muscle underestimate the maximal mitochondrial respiration rate, and this finding needs to be highlighted for adequate interpretation and comparison with literature data.

  3. Measuring Clinical Decision Support Influence on Evidence-Based Nursing Practice.

    PubMed

    Cortez, Susan; Dietrich, Mary S; Wells, Nancy

    2016-07-01

    To measure the effect of clinical decision support (CDS) on oncology nurse evidence-based practice (EBP).
. Longitudinal cluster-randomized design.
. Four distinctly separate oncology clinics associated with an academic medical center.
. The study sample was comprised of randomly selected data elements from the nursing documentation software. The data elements were patient-reported symptoms and the associated nurse interventions. The total sample observations were 600, derived from a baseline, posteducation, and postintervention sample of 200 each (100 in the intervention group and 100 in the control group for each sample).
. The cluster design was used to support randomization of the study intervention at the clinic level rather than the individual participant level to reduce possible diffusion of the study intervention. An elongated data collection cycle (11 weeks) controlled for temporary increases in nurse EBP related to the education or CDS intervention.
. The dependent variable was the nurse evidence-based documentation rate, calculated from the nurse-documented interventions. The independent variable was the CDS added to the nursing documentation software.
. The average EBP rate at baseline for the control and intervention groups was 27%. After education, the average EBP rate increased to 37%, and then decreased to 26% in the postintervention sample. Mixed-model linear statistical analysis revealed no significant interaction of group by sample. The CDS intervention did not result in an increase in nurse EBP.
. EBP education increased nurse EBP documentation rates significantly but only temporarily. Nurses may have used evidence in practice but may not have documented their interventions.
. More research is needed to understand the complex relationship between CDS, nursing practice, and nursing EBP intervention documentation. CDS may have a different effect on nurse EBP, physician EBP, and other medical professional EBP.

  4. Time Clustered Sampling Can Inflate the Inferred Substitution Rate in Foot-And-Mouth Disease Virus Analyses.

    PubMed

    Pedersen, Casper-Emil T; Frandsen, Peter; Wekesa, Sabenzia N; Heller, Rasmus; Sangula, Abraham K; Wadsworth, Jemma; Knowles, Nick J; Muwanika, Vincent B; Siegismund, Hans R

    2015-01-01

    With the emergence of analytical software for the inference of viral evolution, a number of studies have focused on estimating important parameters such as the substitution rate and the time to the most recent common ancestor (tMRCA) for rapidly evolving viruses. Coupled with an increasing abundance of sequence data sampled under widely different schemes, an effort to keep results consistent and comparable is needed. This study emphasizes commonly disregarded problems in the inference of evolutionary rates in viral sequence data when sampling is unevenly distributed on a temporal scale through a study of the foot-and-mouth (FMD) disease virus serotypes SAT 1 and SAT 2. Our study shows that clustered temporal sampling in phylogenetic analyses of FMD viruses will strongly bias the inferences of substitution rates and tMRCA because the inferred rates in such data sets reflect a rate closer to the mutation rate rather than the substitution rate. Estimating evolutionary parameters from viral sequences should be performed with due consideration of the differences in short-term and longer-term evolutionary processes occurring within sets of temporally sampled viruses, and studies should carefully consider how samples are combined.

  5. A study on rheological characteristics of roller milled fenugreek fractions.

    PubMed

    Sakhare, Suresh D; Inamdar, Aashitosh A; Prabhasankar, P

    2016-01-01

    Fenugreek seeds were fractionated by roller milling to get various fractions. The roller milled fractions and whole fenugreek flour (WFF) were evaluated for the flow behavior and time-dependent flow properties using a rotational viscometer at the temperatures of 10-60 (0)C. The samples subjected to a programmed shear rate increase linearly from 0 to 300 s(-1) in 3 min and successive decrease linearly shear rate from 300 s(-1) to 0 in 3 min. The roller milled fractions and WFF paste exhibited non-Newtonian pseudoplastic behavior. Difference in hysteresis loop area was observed among the roller milled fractions and WFF, being more noticeable at lower temperatures. Power law and Casson models were used to predict flow properties of samples. The power law model described well the flow behavior of the roller milled fractions and WFF at temperatures tested. Except flour (FL) fraction, consistency coefficient, m, increased with the temperature both in the forward and backward measurements. The roller milled fractions and WFF exhibited rheopectic behavior that increased viscosity with increasing the shear speed and the temperature. For all the sample tested, initial shear stress increased with increase in shear rate and temperature.

  6. USE OF EXPERT RATINGS AS SAMPLING STRATA FOR A MORE COST-EFFECTIVE PROBABILITY SAMPLE OF A RARE POPULATION

    PubMed Central

    McCaffrey, Daniel; Perlman, Judith; Marshall, Grant N.; Hambarsoomians, Katrin

    2010-01-01

    We consider situations in which externally observable characteristics allow experts to quickly categorize individual households as likely or unlikely to contain a member of a rare target population. This classification can form the basis of disproportionate stratified sampling such that households classified as “unlikely” are sampled at a lower rate than those classified as “likely,” thereby reducing screening costs. Design weights account for this approach and allow unbiased estimates for the target population. We demonstrate that with sensitivity and specificity of expert classification at least 70%, and ideally at least 80%, our approach can economically increase effective sample size for a rare population. We develop heuristics for implementing this approach and demonstrate that sensitivity drives design effects and screening costs whereas specificity only drives the latter. We demonstrate that the potential gains from this approach increase as the target population becomes rarer. We further show that for most applications, unlikely strata should be sampled at 1/6 to ½ the rate of likely strata. This approach was applied to a survey of Cambodian immigrants in which the 82% of households rated “unlikely” were sampled at ¼ the rate as “likely” households, reducing screening from 9.4 to 4.0 approaches per complete. Sensitivity and specificity were 86% and 91% respectively. Weighted estimation had a design effect of 1.26 so screening costs per effective sample size were reduced 47%. We also note that in this instance, expert classification appeared to be uncorrelated with survey outcomes of interest among eligibles. PMID:20936050

  7. Crystallization history of lunar picritic basalt sample 12002 - Phase-equilibria and cooling-rate studies

    NASA Technical Reports Server (NTRS)

    Walker, D.; Kirkpatrick, R. J.; Longhi, J.; Hays, J. F.

    1976-01-01

    Experimental crystallization of a lunar picrite composition (sample 12002) at controlled linear cooling rates produces systematic changes in the temperature at which crystalline phases appear, in the texture, and in crystal morphology as a function of cooling rate. Phases crystallize in the order olivine, chromium spinel, pyroxene, plagioclase, and ilmenite during equilibrium crystallization, but ilmenite and plagioclase reverse their order of appearance and silica crystallizes in the groundmass during controlled cooling experiments. The partition of iron and magnesium between olivine and liquid is independent of cooling rate, temperature, and pressure. Comparison of the olivine nucleation densities in the lunar sample and in the experiments indicates that the sample began cooling at about 1 deg C/hr. Pyroxene size, chemistry, and growth instability spacings, as well as groundmass coarseness, all suggest that the cooling rate subsequently decreased by as much as a factor of 10 or more. The porphyritic texture of this sample, then, is produced at a decreasing, rather than a discontinuously increasing, cooling rate.

  8. Flame Spread Along Free Edges of Thermally Thin Samples in Microgravity

    NASA Technical Reports Server (NTRS)

    Mell, W. E.; Olson, S. L.; Kashiwagi, T.

    2000-01-01

    The effects of imposed flow velocity on flame spread along open edges of a thermally thin cellulosic sample in microgravity are studied experimentally and theoretically. In this study, the sample is ignited locally at the middle of the 4 cm wide sample and subsequent flame spread reaches both open edges of the sample. The following flame behaviors are observed in the experiments and predicted by the numerical calculation; in order of increased imposed flow velocity: (1) ignition but subsequent flame spread is not attained, (2) flame spreads upstream (opposed mode) without any downstream flame, and (3) the upstream flame and two separate downstream flames traveling along the two open edges (concurrent mode). Generally, the upstream and downstream edge flame spread rates are faster than the central flame spread rate for an imposed flow velocity of up to 5 cm/s. This is due to greater oxygen supply from the outer free stream to the edge flames than the central flames, For the upstream edge flame, the greater oxygen supply results in a flame spread rate that is nearly independent of, or decreases gradually, with the imposed flow velocity. The spread rate of the downstream edge, however, increases significantly with the imposed flow velocity.

  9. The forensiX evidence collection tube and its impact on DNA preservation and recovery.

    PubMed

    Garvin, Alex M; Holzinger, Ralf; Berner, Florian; Krebs, Walter; Hostettler, Bernhard; Lardi, Elges; Hertli, Christian; Quartermaine, Roy; Stamm, Christoph

    2013-01-01

    Biological samples are vulnerable to degradation from the time they are collected until they are analysed at the laboratory. Biological contaminants, such as bacteria, fungi, and enzymes, as well as environmental factors, such as sunlight, heat, and humidity, can increase the rate of DNA degradation. Currently, DNA samples are normally dried or frozen to limit their degradation prior to their arrival at the laboratory. In this study, the effect of the sample drying rate on DNA preservation was investigated, as well as a comparison between drying and freezing methods. The drying performances of two commercially available DNA collection tools (swab and drying tube) with different drying rates were evaluated. The swabs were used to collect human saliva, placed into the drying tubes, and stored in a controlled environment at 25°C and 60% relative humidity, or frozen at -20°C, for 2 weeks. Swabs that were stored in fast sample drying tubes yielded 95% recoverable DNA, whereas swabs stored in tubes with slower sample drying rates yielded only 12% recoverable DNA; saliva stored in a microtube at -20°C was used as a control. Thus, DNA sampling tools that offer rapid drying can significantly improve the preservation of DNA collected on a swab, increasing the quantity of DNA available for subsequent analysis.

  10. Effect of fungal decay on the hygroscopic thickness swelling rate of lignocellulosic filler-polyolefin biocomposites

    NASA Astrophysics Data System (ADS)

    Kord, B.; Hosseinihashemi, S. Kh.

    2014-01-01

    The influence of fungal decay on the hygroscopic thickness swelling rate of lignocellulosic filler-polyolefin biocomposites has been investigated. Composites based on polypropylene (PP), bagasse fiber (BF), and a coupling agent (PP-g-MA) were made by melt compounding and injection molding. The weigt ratio of BF to PP was controlled at 60/40 for all blends. The amount of coupling agent was fixed at 2% for all formulations. The samples obtained were exposed to the action of brown-rot (Coniophora puteana) and white-rot (Trametes versicolor) fungi for 8, 12, and 16 weeks according to the Kolle-flask method. The thickness swelling of the samples was evaluated by immersing them in water at room temperature for several weeks. The morphology of the composites was characterized using the scanning electron microscopy (SEM). The results indicated that the fungal decay had an adverse affect on the dimensional stability of BF/PP composites due to an increase in the thickness swelling rate. The thickness swelling of white-rotted samples was higher than that of brown-rotted ones and control samples. Also, the thickness swelling of BF/PP composites increased with increasing time of fungal decay. In addition, after 16 weeks of exposure to white-rot fungi, the composites exhibited a higher parameter of swelling rate K SR than control samples. The K SR of the composites was influenced both by the type of rooting and the exposure time. Furthermore, the SEM micrographs showed that the extent of degradation increased with growing exposure time to fungi.

  11. Temporal trends in emergency department visits for bronchiolitis in the United States, 2006 to 2010.

    PubMed

    Hasegawa, Kohei; Tsugawa, Yusuke; Brown, David F M; Mansbach, Jonathan M; Camargo, Carlos A

    2014-01-01

    To examine temporal trends in emergency departments (EDs) visits for bronchiolitis among US children between 2006 and 2010. Serial, cross-sectional analysis of the Nationwide Emergency Department Sample, a nationally representative sample of ED patients. We used International Classification of Diseases, Ninth Revision, Clinical Modification code 466.1 to identify children <2 years of age with bronchiolitis. Primary outcome measures were rate of bronchiolitis ED visits, hospital admission rate and ED charges. Between 2006 and 2010, weighted national discharge data included 1,435,110 ED visits with bronchiolitis. There was a modest increase in the rate of bronchiolitis ED visits, from 35.6 to 36.3 per 1000 person-years (2% increase; Ptrend = 0.008), due to increases in the ED visit rate among children from 12 months to 23 months (24% increase;Ptrend < 0.001). By contrast, there was a significant decline in the ED visit rate among infants (4% decrease; Ptrend < 0.001). Although unadjusted admission rate did not change between 2006 and 2010 (26% in both years), admission rate declined significantly after adjusting for potential patient- and ED-level confounders (adjusted odds ratio for comparison of 2010 with 2006, 0.84; 95% confidence interval: 0.76-0.93; P < 0.001). Nationwide ED charges for bronchiolitis increased from $337 million to $389 million (16% increase; Ptrend < 0.001), adjusted for inflation. This increase was driven by a rise in geometric mean of ED charges per case from $887 to $1059 (19% increase; Ptrend < 0.001). Between 2006 and 2010, we found a divergent temporal trend in the rate of bronchiolitis ED visits by age group. Despite a significant increase in associated ED charges, ED-associated hospital admission rates for bronchiolitis significantly decreased over this same period.

  12. Light Conditions Affect the Measurement of Oceanic Bacterial Production via Leucine Uptake

    PubMed Central

    Morán, Xosé Anxelu G.; Massana, Ramon; Gasol, Josep M.

    2001-01-01

    The effect of irradiance in the range of 400 to 700 nm or photosynthetically active radiation (PAR) on bacterial heterotrophic production estimated by the incorporation of 3H-leucine (referred to herein as Leu) was investigated in the northwestern Mediterranean Sea and in a coastal North Atlantic site, with Leu uptake rates ranging over 3 orders of magnitude. We performed in situ incubations under natural irradiance levels of Mediterranean samples taken from five depths around solar noon and compared them to incubations in the dark. In two of the three stations large differences were found between light and dark uptake rates for the surfacemost samples, with dark values being on average 133 and 109% higher than in situ ones. Data obtained in coastal North Atlantic waters confirmed that dark enclosure may increase Leu uptake rates more than threefold. To explain these differences, on-board experiments of Leu uptake versus irradiance were performed with Mediterranean samples from depths of 5 and 40 m. Incubations under a gradient of 12 to 1,731 μmol of photons m−2 s−1 evidenced a significant increase in incorporation rates with increasing PAR in most of the experiments, with dark-incubated samples departing from this pattern. These results were not attributed to inhibition of Leu uptake in the light but to enhanced bacterial response when transferred to dark conditions. The ratio of dark to light uptake rates increased as dissolved inorganic nitrogen concentrations decreased, suggesting that bacterial nutrient deficiency was overcome by some process occurring only in the dark bottles. PMID:11525969

  13. Analysis of the cause of increased measles incidence in Xinjiang, China in 2004.

    PubMed

    Yu, Xuelian; Wang, Shaohua; Guan, Jing; Mahemuti; Purhati; Gou, Aili; Liu, Quanming; Jin, Xin; Ghildyal, Reena

    2007-06-01

    Increased number of measles cases were reported from Xinjiang province of China in 2004, relative to previous years. This study aimed to identify the direct cause for this increase in measles morbidity and the major reason for the relatively high measles incidence rate in Xinjiang. The epidemiologic and laboratory surveillance data for measles cases of 2004 were analyzed and a seroepidemiologic investigation involving 1024 subjects, mainly children aged less than 15 years, was conducted in Xinjiang. A questionnaire including demographic and vaccination data was completed by interview and blood samples drawn from surveillance subjects. Sera were analyzed for measles IgM (cases) and IgG (cases and surveillance). Data were assessed for their relationship with high measles incidence rate. 6271 measles cases were reported from Xinjiang in 2004 with a morbidity of 33.7 cases per 100,000 population. 83% of the cases were children less than 12-year-old. 50% of the serum samples were measles IgM positive and 69% were measles IgG positive. 2014 serum samples were collected in the seroepidemiologic survey. The overall IgG antibody seropositivity rate was 89%, preschool children having the lowest seropositivity rate (86%). There was a significant difference in IgG positive rates as well as IgG titers between unvaccinated and vaccinated subjects with each subsequent dose leading to further increase in titer. Low routine measles vaccine coverage was the major probable cause contributing to the increased measles cases in 2004 in Xinjiang and the high measles infection rate overall. The national 2-dose measles vaccination regimen is effective if delivered appropriately.

  14. Effect of ultrasonic waves on the freezing rates of potatoes in degassed coolant and untreated coolant.

    PubMed

    Yu, D Y; Liu, B L

    2014-01-01

    Ultrasonic waves are shown to enhance the rate of freezing. To elucidate the mechanism of immersion freezing of potatos with ultrasonic waves. Ultrasound is applied to potato samples immersed in degassed coolant and untreated coolant. Sonic waves were intermittently applied at temperature below -1 degree C. The freezing rates were measured under different experimental conditions. The use of ultrasonic waves increased the freezing rates of potatoes immersed in both degassed coolant and untreated coolant. However, the freezing rate in the degassed coolant was less than that in the untreated coolant. Heat transfer on the interface between the potato sample and sonicated degassed coolant appears to be less than that within the sample in the absence of cavitation. The interface heat transfer between the potato sample and untreated coolant is likely improved due to ultrasonic cavitation.

  15. Exploring the potential for using 210Pbex measurements within a re-sampling approach to document recent changes in soil redistribution rates within a small catchment in southern Italy.

    PubMed

    Porto, Paolo; Walling, Desmond E; Cogliandro, Vanessa; Callegari, Giovanni

    2016-11-01

    In recent years, the fallout radionuclides caesium-137 ( 137 Cs) and unsupported lead-210 ( 210 Pb ex) have been successfully used to document rates of soil erosion in many areas of the world, as an alternative to conventional measurements. By virtue of their different half-lives, these two radionuclides are capable of providing information related to different time windows. 137 Cs measurements are commonly used to generate information on mean annual erosion rates over the past ca. 50-60 years, whereas 210 Pb ex measurements are able to provide information relating to a longer period of up to ca. 100 years. However, the time-integrated nature of the estimates of soil redistribution provided by 137 Cs and 210 Pb ex measurements can be seen as a limitation, particularly when viewed in the context of global change and interest in the response of soil redistribution rates to contemporary climate change and land use change. Re-sampling techniques used with these two fallout radionuclides potentially provide a basis for providing information on recent changes in soil redistribution rates. By virtue of the effectively continuous fallout input, of 210 Pb, the response of the 210 Pb ex inventory of a soil profile to changing soil redistribution rates and thus its potential for use with the re-sampling approach differs from that of 137 Cs. Its greater sensitivity to recent changes in soil redistribution rates suggests that 210 Pb ex may have advantages over 137 Cs for use in the re-sampling approach. The potential for using 210 Pb ex measurements in re-sampling studies is explored further in this contribution. Attention focuses on a small (1.38 ha) forested catchment in southern Italy. The catchment was originally sampled for 210 Pb ex measurements in 2001 and equivalent samples were collected from points very close to the original sampling points again in 2013. This made it possible to compare the estimates of mean annual erosion related to two different time windows. This comparison suggests that mean annual rates of net soil loss had increased during the period between the two sampling campaigns and that this increase was associated with a shift to an increased sediment delivery ratio. This change was consistent with independent information on likely changes in the sediment response of the study catchment provided by the available records of annual sediment yield and changes in the annual rainfall documented for the local area. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Toward Scalable Boson Sampling with Photon Loss

    NASA Astrophysics Data System (ADS)

    Wang, Hui; Li, Wei; Jiang, Xiao; He, Y.-M.; Li, Y.-H.; Ding, X.; Chen, M.-C.; Qin, J.; Peng, C.-Z.; Schneider, C.; Kamp, M.; Zhang, W.-J.; Li, H.; You, L.-X.; Wang, Z.; Dowling, J. P.; Höfling, S.; Lu, Chao-Yang; Pan, Jian-Wei

    2018-06-01

    Boson sampling is a well-defined task that is strongly believed to be intractable for classical computers, but can be efficiently solved by a specific quantum simulator. However, an outstanding problem for large-scale experimental boson sampling is the scalability. Here we report an experiment on boson sampling with photon loss, and demonstrate that boson sampling with a few photons lost can increase the sampling rate. Our experiment uses a quantum-dot-micropillar single-photon source demultiplexed into up to seven input ports of a 16 ×16 mode ultralow-loss photonic circuit, and we detect three-, four- and fivefold coincidence counts. We implement and validate lossy boson sampling with one and two photons lost, and obtain sampling rates of 187, 13.6, and 0.78 kHz for five-, six-, and seven-photon boson sampling with two photons lost, which is 9.4, 13.9, and 18.0 times faster than the standard boson sampling, respectively. Our experiment shows an approach to significantly enhance the sampling rate of multiphoton boson sampling.

  17. Toward Scalable Boson Sampling with Photon Loss.

    PubMed

    Wang, Hui; Li, Wei; Jiang, Xiao; He, Y-M; Li, Y-H; Ding, X; Chen, M-C; Qin, J; Peng, C-Z; Schneider, C; Kamp, M; Zhang, W-J; Li, H; You, L-X; Wang, Z; Dowling, J P; Höfling, S; Lu, Chao-Yang; Pan, Jian-Wei

    2018-06-08

    Boson sampling is a well-defined task that is strongly believed to be intractable for classical computers, but can be efficiently solved by a specific quantum simulator. However, an outstanding problem for large-scale experimental boson sampling is the scalability. Here we report an experiment on boson sampling with photon loss, and demonstrate that boson sampling with a few photons lost can increase the sampling rate. Our experiment uses a quantum-dot-micropillar single-photon source demultiplexed into up to seven input ports of a 16×16 mode ultralow-loss photonic circuit, and we detect three-, four- and fivefold coincidence counts. We implement and validate lossy boson sampling with one and two photons lost, and obtain sampling rates of 187, 13.6, and 0.78 kHz for five-, six-, and seven-photon boson sampling with two photons lost, which is 9.4, 13.9, and 18.0 times faster than the standard boson sampling, respectively. Our experiment shows an approach to significantly enhance the sampling rate of multiphoton boson sampling.

  18. Passive air sampling using semipermeable membrane devices at different wind-speeds in situ calibrated by performance reference compounds.

    PubMed

    Söderström, Hanna S; Bergqvist, Per-Anders

    2004-09-15

    Semipermeable membrane devices (SPMDs) are passive samplers used to measure the vapor phase of organic pollutants in air. This study tested whether extremely high wind-speeds during a 21-day sampling increased the sampling rates of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs), and whether the release of performance reference compounds (PRCs) was related to the uptakes at different wind-speeds. Five samplers were deployed in an indoor, unheated, and dark wind tunnel with different wind-speeds at each site (6-50 m s(-1)). In addition, one sampler was deployed outside the wind tunnel and one outside the building. To test whether a sampler, designed to reduce the wind-speeds, decreased the uptake and release rates, each sampler in the wind tunnel included two SPMDs positioned inside a protective device and one unprotected SPMD outside the device. The highest amounts of PAHs and PCBs were found in the SPMDs exposed to the assumed highest wind-speeds. Thus, the SPMD sampling rates increased with increasing wind-speeds, indicating that the uptake was largely controlled by the boundary layer at the membrane-air interface. The coefficient of variance (introduced by the 21-day sampling and the chemical analysis) for the air concentrations of three PAHs and three PCBs, calculated using the PRC data, was 28-46%. Thus, the PRCs had a high ability to predict site effects of wind and assess the actual sampling situation. Comparison between protected and unprotected SPMDs showed that the sampler design reduced the wind-speed inside the devices and thereby the uptake and release rates.

  19. The effect of low dose rate irradiation on the tensile properties and microstructure of austenitic stainless steel.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, T. R.; Tsai, H.; Cole, J. I.

    2002-09-17

    To assess the effects of long-term, low-dose-rate neutron exposure on mechanical strength and ductility, tensile properties were measured on 12% and 20% cold-worked Type 316 stainless steel. Samples were prepared from reactor core components retrieved from the EBR-II reactor following final shutdown. Sample locations were chosen to cover a dose range of 1-56 dpa at temperatures from 371-440 C and dose rates from 0.5-5.8 x10{sup -7} dpa/s. These dose rates are approximately an order of magnitude lower than those of typical EBR-II test sample locations. The tensile tests for the 12% CW material were performed at 380 C and 430more » C while those for the 20% CW samples were performed at 370 C. In each case, the tensile test temperature approximately matched the irradiation temperature. To help understand the tensile properties, microstructural samples with similar irradiation history were also examined. The strength and loss of work hardening increase the fastest as a function of irradiation dose for the 12% CW material irradiated at lower temperature. The decrease in ductility with increasing dose occurs more rapidly for the 12% CW material irradiated at lower temperature and the 20% cold-worked material. Post-tensile test fractography indicates that at higher dose, the 20% CW samples begin a shift in fracture mode from purely ductile to mainly small facets and slip bands, suggesting a transition toward channel fracture. The fracture for all of the 12% cold-worked samples was ductile. For both the 12% and 20% CW materials, the yield strength increases correlate with changes in void and loop density and size.« less

  20. Fate of sputum samples transported in bottles containing cetylpyridinium chloride and sodium chloride: a national reference laboratory study.

    PubMed

    Visalakshi, Potharaju; Meharwal, Sandeep K; Arora, Jyoti; Bhalla, Manpreet; Singh, Niti; Myneedu, Vithal Prasad; Behera, Digamber

    2012-04-01

    The transportation of sputum samples may sometimes take more than one week which results in an increased contamination rate and loss of positive cultures. The current study was planned to analyze the recovery rate of mycobacteria from transported samples with and without Cetylpyridinium chloride (CPC). Addition of CPC is useful for isolation of M. tuberculosis from sputum subjected to long-term storage.

  1. Considerations on data acquisition in laser ablation-inductively coupled plasma-mass spectrometry with low-dispersion interfaces

    NASA Astrophysics Data System (ADS)

    Van Malderen, Stijn J. M.; van Elteren, Johannes T.; Šelih, Vid S.; Vanhaecke, Frank

    2018-02-01

    This work describes the aliasing effects induced by undersampling the high-frequency signal patterns generated by a laser ablation-inductively coupled plasma-mass spectrometer equipped with a low-dispersion ablation cell and sequential mass analyzer. By characterizing the width of the signal peak generated from a single shot on the sample, critical experimental parameters, such as the laser repetition rate and detector cycle timings for the individual nuclides can be matched so as to avoid these imaging artifacts (spectral skew) induced by an insufficient sampling rate. By increasing the laser repetition rate by a factor 2-3, masses at the end of the mass scan can be sampled at higher sensitivity. Furthermore, the dwell times can be redistributed over the nuclides of interest based on the signal-to-noise ratio to increase the image contrast.

  2. Seasonal Bacterial Production in a Dimictic Lake as Measured by Increases in Cell Numbers and Thymidine Incorporation

    PubMed Central

    Lovell, Charles R.; Konopka, Allan

    1985-01-01

    Rates of primary and bacterial production in Little Crooked Lake were calculated from the rates of incorporation of H14CO3− and [methyl-3H]thymidine, respectively. Growth rates of bacteria in diluted natural samples were determined for epilimnetic and metalimnetic bacterial populations during the summers of 1982 and 1983. Exponential growth was observed in these diluted samples, with increases in cell numbers of 30 to 250%. No lag was observed in bacterial growth in 14 of 16 experiments. Correlation of bacterial growth rates to corresponding rates of thymidine incorporation by natural samples produced a conversion factor of 2.2 × 1018 cells produced per mole of thymidine incorporated. The mass of the average bacterial cell in the lake was 1.40 × 10−14 ± 0.05 × 10−14 g of C cell−1. Doubling times of natural bacteria calculated from thymidine incorporation rates and in situ cell numbers ranged from 0.35 to 12.00 days (median, 1.50 days). Bacterial production amounted to 66.7 g of C m−2 from April through September, accounting for 29.4% of total (primary plus bacterial) production during this period. The vertical and seasonal distribution of bacterial production in Little Crooked Lake was strongly influenced by the distribution of primary production. From April through September 1983, the depth of maximum bacterial production rates in the water column was related to the depth of high rates of primary production. On a seasonal basis, primary production increased steadily from May through September, and bacterial production increased from May through August and then decreased in September. PMID:16346743

  3. Spectrophotometric Method for the Determination of Atmospheric Cr Pollution as a Factor to Accelerated Corrosion.

    PubMed

    Homa, Dereje; Haile, Ermias; Washe, Alemayehu P

    2017-01-01

    The effect of Cr(VI) pollution on the corrosion rate of corrugated iron roof samples collected from tanning industry areas was investigated through simulated laboratory exposure and spectrophotometric detection of Cr(III) deposit as a product of the reaction. The total level of Cr detected in the samples ranged from 113.892 ± 0.17 ppm to 53.05 ± 0.243 ppm and showed increasing trend as sampling sites get closer to the tannery and in the direction of tannery effluent stream. The laboratory exposure of a newly manufactured material to a simulated condition showed a relatively faster corrosion rate in the presence of Cr(VI) with concomitant deposition of Cr(III) under pH control. A significant ( P = 0.05) increase in the corrosion rate was also recorded when exposing scratched or stress cracked samples. A coupled redox process where Cr(VI) is reduced to a stable, immobile, and insoluble Cr(III) accompanying corrosion of the iron is proposed as a possible mechanism leading to the elevated deposition of the latter on the materials. In conclusion, the increased deposits of Cr detected in the corrugated iron roof samples collected from tanning industry zones suggested possible atmospheric Cr pollution as a factor to the accelerated corrosion of the materials.

  4. Spectrophotometric Method for the Determination of Atmospheric Cr Pollution as a Factor to Accelerated Corrosion

    PubMed Central

    Homa, Dereje; Haile, Ermias

    2017-01-01

    The effect of Cr(VI) pollution on the corrosion rate of corrugated iron roof samples collected from tanning industry areas was investigated through simulated laboratory exposure and spectrophotometric detection of Cr(III) deposit as a product of the reaction. The total level of Cr detected in the samples ranged from 113.892 ± 0.17 ppm to 53.05 ± 0.243 ppm and showed increasing trend as sampling sites get closer to the tannery and in the direction of tannery effluent stream. The laboratory exposure of a newly manufactured material to a simulated condition showed a relatively faster corrosion rate in the presence of Cr(VI) with concomitant deposition of Cr(III) under pH control. A significant (P = 0.05) increase in the corrosion rate was also recorded when exposing scratched or stress cracked samples. A coupled redox process where Cr(VI) is reduced to a stable, immobile, and insoluble Cr(III) accompanying corrosion of the iron is proposed as a possible mechanism leading to the elevated deposition of the latter on the materials. In conclusion, the increased deposits of Cr detected in the corrugated iron roof samples collected from tanning industry zones suggested possible atmospheric Cr pollution as a factor to the accelerated corrosion of the materials. PMID:28469950

  5. Grain size dependence of dynamic mechanical behavior of AZ31B magnesium alloy sheet under compressive shock loading

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Asgari, H., E-mail: hamed.asgari@usask.ca; Odeshi, A.G.; Szpunar, J.A.

    2015-08-15

    The effects of grain size on the dynamic deformation behavior of rolled AZ31B alloy at high strain rates were investigated. Rolled AZ31B alloy samples with grain sizes of 6, 18 and 37 μm, were subjected to shock loading tests using Split Hopkinson Pressure Bar at room temperature and at a strain rate of 1100 s{sup −} {sup 1}. It was found that a double-peak basal texture formed in the shock loaded samples. The strength and ductility of the alloy under the high strain-rate compressive loading increased with decreasing grain size. However, twinning fraction and strain hardening rate were found tomore » decrease with decreasing grain size. In addition, orientation imaging microscopy showed a higher contribution of double and contraction twins in the deformation process of the coarse-grained samples. Using transmission electron microscopy, pyramidal dislocations were detected in the shock loaded sample, proving the activation of pyramidal slip system under dynamic impact loading. - Highlights: • A double-peak basal texture developed in all shock loaded samples. • Both strength and ductility increased with decreasing grain size. • Twinning fraction and strain hardening rate decreased with decreasing grain size. • ‘g.b’ analysis confirmed the presence of dislocations in shock loaded alloy.« less

  6. Influence of dominance rank and affiliation relationships on self-directed behavior in female Tibetan macaques (Macaca thibetana).

    PubMed

    Zhang, Qi-Xin; Li, Jin-Hua; Xia, Dong-Po; Zhu, Yong; Wang, Xi; Zhang, Dao

    2014-05-01

    Self-directed behavior (SDB) is characterized as an indicator of anxiety, frustration and stress in nonhuman primates. In this study, we collected self-directed behavior data from one group of free-ranging Tibetan macaques (Macaca thibetana) at Mt. Huangshan, China (September 2012-May 2013) using a combination of behavioral sampling methods including focal animal sampling, behavioral sampling, continuous sampling and instantaneous sampling. Our results showed that females engaged in significantly higher rates of self-directed behavior when they were in proximity to dominant individuals compared to subordinate ones. Conflict losers significantly increased their SDB rates after agonistic episodes, indicating that SDB might also serve as an index of anxiety in M. thibetana. We further found that females significantly increased their SDB rates when focal individual was proximity to weakly affiliation relationship higher rank members than to strongly affiliation relationship higher rank members. If conflicts were not reconciled, the postconflict SDB rates of losers were higher when they stayed with strongly affiliation opponents; if conflicts were reconciled, victims of strongly affiliation relationships opponents engaged in more SDB rates before reconciliation than after reconciliation, while victims of moderately affiliation relationships opponents did not engaged in more SDB rates before reconciliation than after reconciliation. We conclude that both of dominance rank and affiliation relationships might both influence the SDB rates of female Tibetan macaques significantly, suggesting that SDB is not only an index of anxiety in Tibetan macaques, but also can provide a new insight into evaluation of social relationships between individuals.

  7. Time Series Data Analysis of Wireless Sensor Network Measurements of Temperature.

    PubMed

    Bhandari, Siddhartha; Bergmann, Neil; Jurdak, Raja; Kusy, Branislav

    2017-05-26

    Wireless sensor networks have gained significant traction in environmental signal monitoring and analysis. The cost or lifetime of the system typically depends on the frequency at which environmental phenomena are monitored. If sampling rates are reduced, energy is saved. Using empirical datasets collected from environmental monitoring sensor networks, this work performs time series analyses of measured temperature time series. Unlike previous works which have concentrated on suppressing the transmission of some data samples by time-series analysis but still maintaining high sampling rates, this work investigates reducing the sampling rate (and sensor wake up rate) and looks at the effects on accuracy. Results show that the sampling period of the sensor can be increased up to one hour while still allowing intermediate and future states to be estimated with interpolation RMSE less than 0.2 °C and forecasting RMSE less than 1 °C.

  8. Polar organic chemical integrative sampler (POCIS) uptake rates for 17 polar pesticides and degradation products: laboratory calibration.

    PubMed

    Ibrahim, Imtiaz; Togola, Anne; Gonzalez, Catherine

    2013-06-01

    Polar organic chemical integrative samplers (POCIS) are useful for monitoring a wide range of chemicals, including polar pesticides, in water bodies. However, few calibration data are available, which limits the use of these samplers for time-weighted average concentration measurements in an aquatic medium. This work deals with the laboratory calibration of the pharmaceutical configuration of a polar organic chemical integrative sampler (pharm-POCIS) for calculating the sampling rates of 17 polar pesticides (1.15 ≤  logK(ow) ≤ 3.71) commonly found in water. The experiment, conducted for 21 days in a continuous water flow-through exposure system, showed an integrative accumulation of all studied pesticides for 15 days. Three compounds (metalaxyl, azoxystrobine, and terbuthylazine) remained integrative for the 21-day experiment. The sampling rates measured ranged from 67.9 to 279 mL day(-1) and increased with the hydrophobicity of the pesticides until reaching a plateau where no significant variation in sampling rate is observed when increasing the hydrophobicity.

  9. Acoustic Emission Parameters of Three Gorges Sandstone during Shear Failure

    NASA Astrophysics Data System (ADS)

    Xu, Jiang; Liu, Yixin; Peng, Shoujian

    2016-12-01

    In this paper, an experimental investigation of sandstone samples from the Three Gorges during shear failure was conducted using acoustic emission (AE) and direct shear tests. The AE count rate, cumulative AE count, AE energy, and amplitude of the sandstone samples were determined. Then, the relationships among the AE signals and shearing behaviors of the samples were analyzed in order to detect micro-crack initiation and propagation and reflect shear failure. The results indicated that both the shear strength and displacement exhibited a logarithmic relationship with the displacement rate at peak levels of stress. In addition, the various characteristics of the AE signals were apparent in various situations. The AE signals corresponded with the shear stress under different displacement rates. As the displacement rate increased, the amount of accumulative damage to each specimen decreased, while the AE energy peaked earlier and more significantly. The cumulative AE count primarily increased during the post-peak period. Furthermore, the AE count rate and amplitude exhibited two peaks during the peak shear stress period due to crack coalescence and rock bridge breakage. These isolated cracks later formed larger fractures and eventually caused ruptures.

  10. Rate Constant and Reaction Coordinate of Trp-Cage Folding in Explicit Water

    PubMed Central

    Juraszek, Jarek; Bolhuis, Peter G.

    2008-01-01

    We report rate constant calculations and a reaction coordinate analysis of the rate-limiting folding and unfolding process of the Trp-cage mini-protein in explicit solvent using transition interface sampling. Previous transition path sampling simulations revealed that in this (un)folding process the protein maintains its compact configuration, while a (de)increase of secondary structure is observed. The calculated folding rate agrees reasonably with experiment, while the unfolding rate is 10 times higher. We discuss possible origins for this mismatch. We recomputed the rates with the forward flux sampling method, and found a discrepancy of four orders of magnitude, probably caused by the method's higher sensitivity to the choice of order parameter with respect to transition interface sampling. Finally, we used the previously computed transition path-sampling ensemble to screen combinations of many order parameters for the best model of the reaction coordinate by employing likelihood maximization. We found that a combination of the root mean-square deviation of the helix and of the entire protein was, of the set of tried order parameters, the one that best describes the reaction coordination. PMID:18676648

  11. Understanding erosion rates in the Himalayan orogen: A case study from the Arun Valley

    NASA Astrophysics Data System (ADS)

    Olen, Stephanie M.; Bookhagen, Bodo; Hoffmann, Bernd; Sachse, Dirk; Adhikari, D. P.; Strecker, Manfred R.

    2015-10-01

    Understanding the rates and pattern of erosion is a key aspect of deciphering the impacts of climate and tectonics on landscape evolution. Denudation rates derived from terrestrial cosmogenic nuclides (TCNs) are commonly used to quantify erosion and bridge tectonic (Myr) and climatic (up to several kiloyears) time scales. However, how the processes of erosion in active orogens are ultimately reflected in 10Be TCN samples remains a topic of discussion. We investigate this problem in the Arun Valley of eastern Nepal with 34 new 10Be-derived catchment-mean denudation rates. The Arun Valley is characterized by steep north-south gradients in topography and climate. Locally, denudation rates increase northward, from <0.2 mm yr-1 to ~1.5 mm yr-1 in tributary samples, while main stem samples appear to increase downstream from ~0.2 mm yr-1 at the border with Tibet to 0.91 mm yr-1 in the foreland. Denudation rates most strongly correlate with normalized channel steepness (R2 = 0.67), which has been commonly interpreted to indicate tectonic activity. Significant downstream decrease of 10Be concentration in the main stem Arun suggests that upstream sediment grains are fining to the point that they are operationally excluded from the processed sample. This results in 10Be concentrations and denudation rates that do not uniformly represent the upstream catchment area. We observe strong impacts on 10Be concentrations from local, nonfluvial geomorphic processes, such as glaciation and landsliding coinciding with areas of peak rainfall rates, pointing toward climatic modulation of predominantly tectonically driven denudation rates.

  12. Enhanced Microbial Survivability in Subzero Brines.

    PubMed

    Heinz, Jacob; Schirmack, Janosch; Airo, Alessandro; Kounaves, Samuel P; Schulze-Makuch, Dirk

    2018-04-17

    It is well known that dissolved salts can significantly lower the freezing point of water and thus extend habitability to subzero conditions. However, most investigations thus far have focused on sodium chloride as a solute. In this study, we report on the survivability of the bacterial strain Planococcus halocryophilus in sodium, magnesium, and calcium chloride or perchlorate solutions at temperatures ranging from +25°C to -30°C. In addition, we determined the survival rates of P. halocryophilus when subjected to multiple freeze/thaw cycles. We found that cells suspended in chloride-containing samples have markedly increased survival rates compared with those in perchlorate-containing samples. In both cases, the survival rates increase with lower temperatures; however, this effect is more pronounced in chloride-containing samples. Furthermore, we found that higher salt concentrations increase survival rates when cells are subjected to freeze/thaw cycles. Our findings have important implications not only for the habitability of cold environments on Earth but also for extraterrestrial environments such as that of Mars, where cold brines might exist in the subsurface and perhaps even appear temporarily at the surface such as at recurring slope lineae. Key Words: Brines-Halophile-Mars-Perchlorate-Subzero-Survival. Astrobiology 18, xxx-xxx.

  13. Factors limiting success of inoculation to enhance biodegradation of low concentrations of organic chemicals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zaidi, B.R.; Murakami, Y.; Alexander, M.

    1988-12-01

    Corynebacterium sp. added to lake water rapidly mineralized 100 ..mu..g and 1.0 mg of p-nitrophenol (PNP)/L but acted very slowly on the substrate present at 26 ..mu..g/L. The rate and extent of mineralization of the lowest PNP concentration in Beebe Lake water varied according to the time the sample was taken and were directly related to rainfall, and presumably runoff, in the watershed. The addition of high concentrations of inorganic P or N to water samples collected after a drought period, during which mineralization by the bacterium was slow, enhanced PNP decomposition. Mineralization in Cayuga Lake water was increased slightlymore » by 10 mg of K/sub 2/HPO/sub 4//L, but the enhancement was marked by 100 mg/L. The stimulation was a response to P and K. Glucose stimulated PNP mineralization in samples from Beebe and Cayuga Lakes, and K/sub 2/HOP/sub 4/ further increased the rate and extent of the transformation. The addition of either of two eucaryotic inhibitors increased the rate of Corynebacterium sp. growth in lake water amended with 26 ..mu..g of PNP/L but decreased the rate of mineralization.« less

  14. A comprehensive study of sampling-based optimum signal detection in concentration-encoded molecular communication.

    PubMed

    Mahfuz, Mohammad U; Makrakis, Dimitrios; Mouftah, Hussein T

    2014-09-01

    In this paper, a comprehensive analysis of the sampling-based optimum signal detection in ideal (i.e., free) diffusion-based concentration-encoded molecular communication (CEMC) system has been presented. A generalized amplitude-shift keying (ASK)-based CEMC system has been considered in diffusion-based noise and intersymbol interference (ISI) conditions. Information is encoded by modulating the amplitude of the transmission rate of information molecules at the TN. The critical issues involved in the sampling-based receiver thus developed are addressed in detail, and its performance in terms of the number of samples per symbol, communication range, and transmission data rate is evaluated. ISI produced by the residual molecules deteriorates the performance of the CEMC system significantly, which further deteriorates when the communication range and/or the transmission data rate increase(s). In addition, the performance of the optimum receiver depends on the receiver's ability to compute the ISI accurately, thus providing a trade-off between receiver complexity and achievable bit error rate (BER). Exact and approximate detection performances have been derived. Finally, it is found that the sampling-based signal detection scheme thus developed can be applied to both binary and multilevel (M-ary) ASK-based CEMC systems, although M-ary systems suffer more from higher BER.

  15. Prediction of Three-Dimensional Downward Flame Spread Characteristics over Poly(methyl methacrylate) Slabs in Different Pressure Environments.

    PubMed

    Zhao, Kun; Zhou, Xiao-Dong; Liu, Xue-Qiang; Lu, Lei; Wu, Zhi-Bo; Peng, Fei; Ju, Xiao-Yu; Yang, Li-Zhong

    2016-11-22

    The present study is aimed at predicting downward flame spread characteristics over poly(methyl methacrylate) (PMMA) with different sample dimensions in different pressure environments. Three-dimensional (3-D) downward flame spread experiments on free PMMA slabs were conducted at five locations with different altitudes, which provide different pressures. Pressure effects on the flame spread rate, profile of pyrolysis front and flame height were analyzed at all altitudes. The flame spread rate in the steady-state stage was calculated based on the balance on the fuel surface and fuel properties. Results show that flame spread rate increases exponentially with pressure, and the exponent of pressure further shows an increasing trend with the thickness of the sample. The angle of the pyrolysis front emerged on sample residue in the width direction, which indicates a steady-burning stage, varies clearly with sample thicknesses and ambient pressures. A global non-dimensional equation was proposed to predict the variation tendency of the angle of the pyrolysis front with pressure and was found to fit well with the measured results. In addition, the dependence of average flame height on mass burning rate, sample dimension and pressure was proposed based on laminar diffusion flame theory. The fitted exponent of experimental data is 1.11, which is close to the theoretical value.

  16. [Spectral analysis of Heart Rate Variability in psychiatric patients: autonomic nervous system evaluation in psychotic, anxiety and depressive disorders].

    PubMed

    Lo Turco, Giovanni; Grimaldi Di Terresena, Liria

    2012-01-01

    The aim of this study was to test the primary hypothesis of altered Heart Rate Variability (HRV) and heart rate in a sample of patients with mental disorders and the secondary hypothesis of normalization of HRV values as a result of clinical improvement. The study was conducted on a sample of 90 patients with psychotic, anxiety and mood disorders. Each patient was subjected to detection of HRV and heart rate via a photoplethysmographic sensor and evaluated with rating scales based on the specific disorder. The parameters detected in the sample were compared with a control group of healthy subjects. There were no significant differences of cardiac autonomic modulation between the group of patients in whom is possible exclude the drug influence and the control group; significantly lower values of HRV parameters in the group of patients with drug influence, and especially in subgroup of psychotic patients, compared to controls, are, instead, detected. The study also shows a significant increase in heart rate as a common feature in mental disorders, regardless of treatment. Clinical improvement appears to promote the normalization of the variability in patients with high DS of tachogram. The study suggests a potential increased risk of cardiovascular mortality in patients, as evidenced by the increased values of heart rate, regardless of drug treatment. This risk is even more pronounced in psychotic patients in drug treatment because of the simultaneous significant reduction of HRV parameters.

  17. Using Elderly Educators to Increase Colorectal Cancer Screening.

    ERIC Educational Resources Information Center

    Weinrich, Sally P.; And Others

    1993-01-01

    Used elderly educator method for increasing rate of return of fecal occult blood sampling in colorectal screening among 171 socioeconomically disadvantaged older persons. Two methods using elderly educators had overall response rate of more than 60%. Found statistically significant difference between two methods that used elderly educators and two…

  18. Development of a passive air sampler to measure airborne organophosphorus pesticides and oxygen analogs in an agricultural community.

    PubMed

    Armstrong, Jenna L; Yost, Michael G; Fenske, Richard A

    2014-09-01

    Organophosphorus pesticides are some of the most widely used insecticides in the US, and spray drift may result in human exposures. We investigate sampling methodologies using the polyurethane foam passive air sampling device to measure cumulative monthly airborne concentrations of OP pesticides chlorpyrifos, azinphos-methyl, and oxygen analogs. Passive sampling rates (m(3)d(-1)) were determined using calculations using chemical properties, loss of depuration compounds, and calibration with side-by-side active air sampling in a dynamic laboratory exposure chamber and in the field. The effects of temperature, relative humidity, and wind velocity on outdoor sampling rates were examined at 23 sites in Yakima Valley, Washington. Indoor sampling rates were significantly lower than outdoors. Outdoor rates significantly increased with average wind velocity, with high rates (>4m(3)d(-1)) observed above 8ms(-1). In exposure chamber studies, very little oxygen analog was observed on the PUF-PAS, yet substantial amounts chlorpyrifos-oxon and azinphos methyl oxon were measured in outdoor samples. PUF-PAS is a practical and useful alternative to AAS because it results in little artificial transformation to the oxygen analog during sampling, it provides cumulative exposure estimates, and the measured sampling rates were comparable to rates for other SVOCs. It is ideal for community based participatory research due to low subject burden and simple deployment in remote areas. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Adding Postal Follow-Up to a Web-Based Survey of Primary Care and Gastroenterology Clinic Physician Chiefs Improved Response Rates but not Response Quality or Representativeness.

    PubMed

    Partin, Melissa R; Powell, Adam A; Burgess, Diana J; Haggstrom, David A; Gravely, Amy A; Halek, Krysten; Bangerter, Ann; Shaukat, Aasma; Nelson, David B

    2015-09-01

    This study assessed whether postal follow-up to a web-based physician survey improves response rates, response quality, and representativeness. We recruited primary care and gastroenterology chiefs at 125 Veterans Affairs medical facilities to complete a 10-min web-based survey on colorectal cancer screening and diagnostic practices in 2010. We compared response rates, response errors, and representativeness in the primary care and gastroenterology samples before and after adding postal follow-up. Adding postal follow-up increased response rates by 20-25 percentage points; markedly greater increases than predicted from a third e-mail reminder. In the gastroenterology sample, the mean number of response errors made by web responders (0.25) was significantly smaller than the mean number made by postal responders (2.18), and web responders provided significantly longer responses to open-ended questions. There were no significant differences in these outcomes in the primary care sample. Adequate representativeness was achieved before postal follow-up in both samples, as indicated by the lack of significant differences between web responders and the recruitment population on facility characteristics. We conclude adding postal follow-up to this web-based physician leader survey improved response rates but not response quality or representativeness. © The Author(s) 2013.

  20. Efficacy of adrenal venous sampling is increased by point of care cortisol analysis

    PubMed Central

    Viste, Kristin; Grytaas, Marianne A; Jørstad, Melissa D; Jøssang, Dag E; Høyden, Eivind N; Fotland, Solveig S; Jensen, Dag K; Løvås, Kristian; Thordarson, Hrafnkell; Almås, Bjørg; Mellgren, Gunnar

    2013-01-01

    Primary aldosteronism (PA) is a common cause of secondary hypertension and is caused by unilateral or bilateral adrenal disease. Treatment options depend on whether the disease is lateralized or not, which is preferably evaluated with selective adrenal venous sampling (AVS). This procedure is technically challenging, and obtaining representative samples from the adrenal veins can prove difficult. Unsuccessful AVS procedures often require reexamination. Analysis of cortisol during the procedure may enhance the success rate. We invited 21 consecutive patients to participate in a study with intra-procedural point of care cortisol analysis. When this assay showed nonrepresentative sampling, new samples were drawn after redirection of the catheter. The study patients were compared using the 21 previous procedures. The intra-procedural cortisol assay increased the success rate from 10/21 patients in the historical cohort to 17/21 patients in the study group. In four of the 17 successful procedures, repeated samples needed to be drawn. Successful sampling at first attempt improved from the first seven to the last seven study patients. Point of care cortisol analysis during AVS improves success rate and reduces the need for reexaminations, in accordance with previous studies. Successful AVS is crucial when deciding which patients with PA will benefit from surgical treatment. PMID:24169597

  1. Contributions of Various Radiological Sources to Background in a Suburban Environment

    DOE PAGES

    Milvenan, Richard D.; Hayes, Robert B.

    2016-11-01

    This work is a brief overview and comparison of dose rates stemming from both indoor and outdoor natural background radiation and household objects within a suburban environment in North Carolina. Combined gamma and beta dose rates were taken from indoor objects that ranged from the potassium in fruit to the americium in smoke detectors. For outdoor measurements, various height and time data samples were collected to show fluctuations in dose rate due to temperature inversion and geometric attenuation. Although each sample tested proved to have a statistically significant increase over background using Students t-test, no sample proved to be moremore » than a minor increase in natural radiation dose. Furthermore, the relative contributions from natural radioactivity such as potassium in foods and common household items are shown to be easily distinguished from background using standard handheld instrumentation when applied in a systematic, methodological manner.« less

  2. Contributions of Various Radiological Sources to Background in a Suburban Environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Milvenan, Richard D.; Hayes, Robert B.

    This work is a brief overview and comparison of dose rates stemming from both indoor and outdoor natural background radiation and household objects within a suburban environment in North Carolina. Combined gamma and beta dose rates were taken from indoor objects that ranged from the potassium in fruit to the americium in smoke detectors. For outdoor measurements, various height and time data samples were collected to show fluctuations in dose rate due to temperature inversion and geometric attenuation. Although each sample tested proved to have a statistically significant increase over background using Students t-test, no sample proved to be moremore » than a minor increase in natural radiation dose. Furthermore, the relative contributions from natural radioactivity such as potassium in foods and common household items are shown to be easily distinguished from background using standard handheld instrumentation when applied in a systematic, methodological manner.« less

  3. Shielding experiments by the JASMIN Collaboration at Fermilab (II) - radioactivity measurement induced by secondary particles from the anti-proton production target

    DOE PAGES

    Hiroshi, Yashima; Norihiro, Matsuda; Yoshimi, Kasugai; ...

    2011-08-01

    The JASMIN Collaboration has performed an experiment to conduct measurements of nuclear reaction rates around the anti-proton production (Pbar) target at the Fermi National Accelerator Laboratory (FNAL). At the Pbar target station, the target, consisting of an Inconel 600 cylinder, was irradiated by a 120 GeV/c proton beam from the FNAL Main Injector. The beam intensity was 3.6 x 10 12 protons per second. The samples of Al, Nb, Cu, and Au were placed near the target to investigate the spatial and energy distribution of secondary particles emitted from it. After irradiation, the induced activities of the samples were measuredmore » by studying their gamma ray spectra using HPGe detectors. The production rates of 30 nuclides induced in Al, Nb, Cu, Au samples were obtained. These rates increase for samples placed in a forward (small angle) position relative to the target. The angular dependence of these reaction rates becomes larger for increasing threshold energy. These experimental results are compared with Monte Carlo calculations. The calculated results generally agree with the experimental results to within a factor of 2 to 3.« less

  4. Shielding experiments by the JASMIN collaboration at Fermilab (II) - Radioactivity measurement induced by secondary particles from the anti-proton production target

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yashima, Hiroshi; /Kyoto U., KURRI; Matsuda, Norihiro

    2011-01-01

    The JASMIN Collaboration has performed an experiment to conduct measurements of nuclear reaction rates around the anti-proton production (Pbar) target at the Fermi National Accelerator Laboratory (FNAL). At the Pbar target station, the target, consisting an Inconel 600 cylinder, was irradiated by a 120 GeV/c proton beam from the FNAL Main Injector. The beam intensity was 3.6 x 10{sub 12} protons per second. Samples of Al, Nb, Cu, and Au were placed near the target to investigate the spatial and energy distribution of secondary particles emitted from it. After irradiation, the induced activities of the samples were measured by studyingmore » their gamma ray spectra using HPGe detectors. The production rates of 30 nuclides induced in Al, Nb, Cu, Au samples were obtained. These rates increase for samples placed in a forward (small angle) position relative to the target. The angular dependence of these reaction rates becomes larger for increasing threshold energy. These experimental results are compared with Monte Carlo calculations. The calculated results generally agree with the experimental results to within a factor of 2 to 3.« less

  5. Maximum inflation of the type 1 error rate when sample size and allocation rate are adapted in a pre-planned interim look.

    PubMed

    Graf, Alexandra C; Bauer, Peter

    2011-06-30

    We calculate the maximum type 1 error rate of the pre-planned conventional fixed sample size test for comparing the means of independent normal distributions (with common known variance) which can be yielded when sample size and allocation rate to the treatment arms can be modified in an interim analysis. Thereby it is assumed that the experimenter fully exploits knowledge of the unblinded interim estimates of the treatment effects in order to maximize the conditional type 1 error rate. The 'worst-case' strategies require knowledge of the unknown common treatment effect under the null hypothesis. Although this is a rather hypothetical scenario it may be approached in practice when using a standard control treatment for which precise estimates are available from historical data. The maximum inflation of the type 1 error rate is substantially larger than derived by Proschan and Hunsberger (Biometrics 1995; 51:1315-1324) for design modifications applying balanced samples before and after the interim analysis. Corresponding upper limits for the maximum type 1 error rate are calculated for a number of situations arising from practical considerations (e.g. restricting the maximum sample size, not allowing sample size to decrease, allowing only increase in the sample size in the experimental treatment). The application is discussed for a motivating example. Copyright © 2011 John Wiley & Sons, Ltd.

  6. Study of sampling rate influence on neutron-gamma discrimination with stilbene coupled to a silicon photomultiplier.

    PubMed

    Zhang, Jinglong; Moore, Michael E; Wang, Zhonghai; Rong, Zhou; Yang, Chaowen; Hayward, Jason P

    2017-10-01

    Choosing a digitizer with an appropriate sampling rate is often a trade-off between performance and economy. The influence of sampling rates on the neutron-gamma Pulse Shape Discrimination (PSD) with a solid stilbene scintillator coupled to a Silicon Photomultiplier was investigated in this work. Sampling rates from 125MSPS to 2GSPS from a 10-bit digitizer were used to collect detector pulses produced by the interactions of a Cf-252 source. Due to the decreased signal-to-noise ratio (SNR), the PSD performance degraded with reduced sampling rates. The reason of PSD performance degradation was discussed. Then, an efficient combination of filtering and digital signal processing (DSP) was then applied to suppress the timing noise and electronic background noise. The results demonstrate an improved PSD performance especially at low sampling rates, down to 125MSPS. Using filtering and DSP, the ascribed Figure of Merit (FOM) at 125keV ee (± 10keV ee ) increased from 0.95 to 1.02 at 125MSPS. At 300keV ee and above, all the FOMs are better than 2.00. Our study suggests that 250MSPS is a good enough sampling rate for neutron-gamma discrimination in this system in order to be sensitive to neutrons at and above ~ 125keV ee . Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Prediction of near-term increases in suicidal ideation in recently depressed patients with bipolar II disorder using intensive longitudinal data.

    PubMed

    Depp, Colin A; Thompson, Wesley K; Frank, Ellen; Swartz, Holly A

    2017-01-15

    There are substantial gaps in understanding near-term precursors of suicidal ideation in bipolar II disorder. We evaluated whether repeated patient-reported mood and energy ratings predicted subsequent near-term increases in suicide ideation. Secondary data were used from 86 depressed adults with bipolar II disorder enrolled in one of 3 clinical trials evaluating Interpersonal and Social Rhythm Therapy and/or pharmacotherapy as treatments for depression. Twenty weeks of daily mood and energy ratings and weekly Hamilton Depression Rating Scale (HDRS) were obtained. Penalized regression was used to model trajectories of daily mood and energy ratings in the 3 week window prior to HDRS Suicide Item ratings. Participants completed an average of 68.6 (sd=52) days of mood and energy ratings. Aggregated across the sample, 22% of the 1675 HDRS Suicide Item ratings were non-zero, indicating presence of at least some suicidal thoughts. A cross-validated model with longitudinal ratings of energy and depressed mood within the three weeks prior to HDRS ratings resulted in an AUC of 0.91 for HDRS Suicide item >2, accounting for twice the variation when compared to baseline HDRS ratings. Energy, both at low and high levels, was an earlier predictor than mood. Data derived from a heterogeneous treated sample may not generalize to naturalistic samples. Identified suicidal behavior was absent from the sample so it could not be predicted. Prediction models coupled with intensively gathered longitudinal data may shed light on the dynamic course of near-term risk factors for suicidal ideation in bipolar II disorder. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Maximum type I error rate inflation from sample size reassessment when investigators are blind to treatment labels.

    PubMed

    Żebrowska, Magdalena; Posch, Martin; Magirr, Dominic

    2016-05-30

    Consider a parallel group trial for the comparison of an experimental treatment to a control, where the second-stage sample size may depend on the blinded primary endpoint data as well as on additional blinded data from a secondary endpoint. For the setting of normally distributed endpoints, we demonstrate that this may lead to an inflation of the type I error rate if the null hypothesis holds for the primary but not the secondary endpoint. We derive upper bounds for the inflation of the type I error rate, both for trials that employ random allocation and for those that use block randomization. We illustrate the worst-case sample size reassessment rule in a case study. For both randomization strategies, the maximum type I error rate increases with the effect size in the secondary endpoint and the correlation between endpoints. The maximum inflation increases with smaller block sizes if information on the block size is used in the reassessment rule. Based on our findings, we do not question the well-established use of blinded sample size reassessment methods with nuisance parameter estimates computed from the blinded interim data of the primary endpoint. However, we demonstrate that the type I error rate control of these methods relies on the application of specific, binding, pre-planned and fully algorithmic sample size reassessment rules and does not extend to general or unplanned sample size adjustments based on blinded data. © 2015 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd. © 2015 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd.

  9. Bedload Rating and Flow Competence Curves Vary With Watershed and Bed Material Parameters

    NASA Astrophysics Data System (ADS)

    Bunte, K.; Abt, S. R.

    2003-12-01

    Bedload transport rating curves and flow competence curves (largest bedload size for specified flow) are usually not known for streams unless a large number of bedload samples has been collected and analyzed. However, this information is necessary for assessing instream flow needs and stream responses to watershed effects. This study therefore analyzed whether bedload transport rating and flow competence curves were related to stream parameters. Bedload transport rating curves and flow competence curves were obtained from extensive bedload sampling in six gravel- and cobble-bed mountain streams. Samples were collected using bedload traps and a large net sampler, both of which provide steep and relatively well-defined bedload rating and flow competence curves due to a long sampling duration, a large sampler opening and a large sampler capacity. The sampled streams have snowmelt regimes, steep (1-9%) gradients, and watersheds that are mainly forested and relatively undisturbed with basin area sizes of 8 to 105 km2. The channels are slightly incised and can contain flows of more than 1.5 times bankfull with little overbank flow. Exponents of bedload rating and flow competence curves obtained from these measurements were found to systematically increase with basin area size and decrease with the degree of channel armoring. By contrast, coefficients of bedload rating and flow competence curves decreased with basin size and increased with armoring. All of these relationships were well-defined (0.86 < r2 < 0.99). Data sets from other studies in coarse-bedded streams fit the indicated trend if the sampling device used allows measuring bedload transport rates over a wide range and if bedload supply is somewhat low. The existence of a general positive trend between bedload rating curve exponents and basin area, and a negative trend between coefficients and basin area, is confirmed by a large data set of bedload rating curves obtained from Helley-Smith samples. However, in this case, the trends only become visible as basin area sizes span a wide range (1 - 10,000 km2). The well-defined relationships obtained from the bedload trap and the large net sampler suggest that exponents and coefficients of bedload transport rating curves (and flow competence curves) are predictable from an easily obtainable parameter such as basin size. However, the relationships of bedload rating curve exponents and coefficients with basin size and armoring appear to be influenced by the sampling device used and the watershed sediment production.

  10. The Time-Dependency of Deformation in Porous Carbonate Rocks

    NASA Astrophysics Data System (ADS)

    Kibikas, W. M.; Lisabeth, H. P.; Zhu, W.

    2016-12-01

    Porous carbonate rocks are natural reservoirs for freshwater and hydrocarbons. More recently, due to their potential for geothermal energy generation as well as carbon sequestration, there are renewed interests in better understanding of the deformation behavior of carbonate rocks. We conducted a series of deformation experiments to investigate the effects of strain rate and pore fluid chemistry on rock strength and transport properties of porous limestones. Indiana limestone samples with initial porosity of 16% are deformed at 25 °C under effective pressures of 10, 30, and 50 MPa. Under nominally dry conditions, the limestone samples are deformed under 3 different strain rates, 1.5 x 10-4 s-1, 1.5 x 10-5 s-1 and 1.5 x 10-6 s-1 respectively. The experimental results indicate that the mechanical behavior is both rate- and pressure-dependent. At low confining pressures, post-yielding deformation changes from predominantly strain softening to strain hardening as strain rate decreases. At high confining pressures, while all samples exhibit shear-enhanced compaction, decreasing strain rate leads to an increase in compaction. Slower strain rates enhance compaction at all confining pressure conditions. The rate-dependence of deformation behaviors of porous carbonate rocks at dry conditions indicates there is a strong visco-elastic coupling for the degradation of elastic modulus with increasing plastic deformation. In fluid saturated samples, inelastic strain of limestone is partitioned among low temperature plasticity, cataclasis and solution transport. Comparison of inelastic behaviors of samples deformed with distilled water and CO2-saturated aqueous solution as pore fluids provide experimental constraints on the relative activities of the various mechanisms. Detailed microstructural analysis is conducted to take into account the links between stress, microstructure and the inelastic behavior and failure mechanisms.

  11. Metallographic cooling rates of L-group ordinary chondrites

    NASA Technical Reports Server (NTRS)

    Bennett, Marvin E.; Mcsween, Harry Y., Jr.

    1993-01-01

    Shock metamorphism appears to be a ubiquitous feature in L-group ordinary chondrites. Brecciation and heterogeneous melting obscure much of the early history of this meteorite group and have caused confusion as to whether L chondrites have undergone thermal metamorphism within onion-shell or rubble-pile parent bodies. Employing the most recent shock criteria, we have examined 55 Antarctic and 24 non-Antarctic L chondrites in order to identify those which have been least affected by post-accretional shock. Six low-shock samples (those with shock grade less than S4) of petrographic types L3-L5 were selected from both populations and metallographic cooling rates were obtained following the technique of Willis and Goldstein. All non-Antarctic L6 chondrites inspected were too heavily shocked to be included in this group. However, 4 shocked L6 chondrites were analyzed in order to determine what effects shock may impose on metallographic cooling rates. Metallographic cooling rates were derived by analyzing the cores of taenite grains and then measuring the distance to the nearest grain edge. Taenites were identified using backscatter imaging on a Cameca SX-50 electron microprobe. Using backscatter we were able to locate homogeneous, rust-free, nearly spherical grains. M-shaped profiles taken from grain traverses were also used to help locate the central portions of selected grains. All points which contained phosphorus above detection limits were discarded. Plots of cooling-rate data are summarized and data from the high-shock samples are presented. The lack of coherency of cooling rates for individual samples is indicative of heterogeneous cooling following shock. The data confirms the statement expressed by numerous workers that extreme care must be taken when selecting samples of L chondrites for cooling-rate studies. Data for the 6 non-Antarctic low-shock samples are also presented. The samples display a general trend in cooling rates. The lowest metamorphic grade yielded the slowest cooling rates and an increase in grade follows an increase in cooling rate. This is the opposite relationship to that predicted by the onion-shell model.

  12. International collaboration in medical radiation science.

    PubMed

    Denham, Gary; Allen, Carla; Platt, Jane

    2016-06-01

    International collaboration is recognised for enhancing the ability to approach complex problems from a variety of perspectives, increasing development of a wider range of research skills and techniques and improving publication and acceptance rates. The aim of this paper is to describe the current status of international collaboration in medical radiation science and compare this to other allied health occupations. This study utilised a content analysis approach where co-authorship of a journal article was used as a proxy for research collaboration and the papers were assigned to countries based on the corporate address given in the by-line of the publication. A convenience sample method was employed and articles published in the professional medical radiation science journals in the countries represented within our research team - Australia, the United Kingdom (UK) and the United States of America (USA) were sampled. Physiotherapy, speech pathology, occupational therapy and nursing were chosen for comparison. Rates of international collaboration in medical radiation science journals from Australia, the UK and the USA have steadily increased over the 3-year period sampled. Medical radiation science demonstrated lower average rates of international collaboration than the other allied health occupations sampled. The average rate of international collaboration in nursing was far below that of the allied health occupations sampled. Overall, the UK had the highest average rate of international collaboration, followed by Australia and the USA, the lowest. Overall, medical radiation science is lagging in international collaboration in comparison to other allied health fields.

  13. Evaluation of the effect of ammonia on nicotine pharmacokinetics using rapid arterial sampling.

    PubMed

    McKinney, Diana L; Gogova, Maria; Davies, Bruce D; Ramakrishnan, Viswanathan; Fisher, Kelly; Carter, W Hans; Karnes, H Thomas; Garnett, William R; Iyer, Sunil S; Somani, Amit A; Kobal, Gerd; Barr, William H

    2012-05-01

    The nicotine bolus theory states that the dependence-producing potential of cigarettes relates to a rapid increase in nicotine at brain receptor sites. It has been suggested that ammonia, a compound typically found in tobacco products, further increases the amount of nicotine absorbed and its absorption rate. The aim of this study was to determine whether different ammonia yields in cigarettes affected the rate or amount of nicotine absorption from the lungs to arterial circulation. 34 adult smokers received 3 separate puffs from each of 2 test cigarettes with different ammonia yields (ammonia in smoke: 10.1 μg per cigarette vs. 18.9 μg per cigarette), followed by rapid radial arterial blood sampling (maximum one sample per second) with 30 min between puffs. Arterial blood samples were assayed for nicotine by liquid chromatography tandem mass spectrometry. Pharmacokinetic modeling was performed and the two test cigarettes were assessed for bioequivalence. No significant differences were found in area under the curve, C(max), or T((max)) and the 2 test cigarettes were found to be bioequivalent based on 2 one-sided tests at a significance level of 5%. In addition, the zero-order rate constant (k(0)) obtained from the initial slope of the curves and the model-dependent first-order rate constant (k(a)) were not significantly different. This study provides strong evidence that the different ammonia yields of the test cigarettes had no impact on nicotine pharmacokinetics; thus, the ammonia did not increase the rate or amount of nicotine absorption from a puff of cigarette smoke.

  14. Intransience of functional components and distinctive properties of amla (Indian gooseberry) ice cream during short-term storage.

    PubMed

    Goraya, Rajpreet Kaur; Bajwa, Usha

    2018-05-01

    Inclusion of processed amla have been found to enhance the functional properties and nutritional value of ice cream by augmenting the fiber content, total phenols, tannins, ascorbic acid and antioxidant activity. The present investigation assessed the changes in these constituents, color values (L, a* and b*), melting rate, sensory scores and microbiological quality of ice cream containing amla shreds, pulp, preserve, candy and powder during 60 days' storage at - 18 to - 20 °C. The total solids increased slightly whereas the antioxidant activity, total phenols, ascorbic acid and tannins decreased on storage. The L values declined whereas a* and b* values amplified, the rate of change being highest in candy containing sample followed by preserve. The first drip time of all the samples increased whereas melting rate decreased. The overall acceptability scores declined non significantly. Standard plate count of all the ice cream samples decreased significantly whereas yeast and molds were not detected throughout the storage. The psychrophiles were not spotted up to 30 days, thereafter, a small increase was observed.

  15. High-Impact Aerobic and Zumba Fitness on Increasing VO2MAX, Heart Rate Recovery and Skinfold Thickness

    NASA Astrophysics Data System (ADS)

    Suminar, T. J.; Kusnanik, N. W.; Wiriawan, O.

    2018-01-01

    Purpose of this study is to determine the significant effect of high-impact aerobics exercise, and Zumba fitness on increasing VO2Max, decreasing of heart rate recovery, and decreasing of skinfold thickness. A sample of this study is 30 members aerobics of student activity unit. Type of this study was quantitative by using a quasi-experimental design method. The design of this study used Matching-Only Design. Data were Analyzed by using the t test (paired t-test). The samples divided into three groups consisted of experimental group I, experimental group II, and control group. They were given a treatment for 8 weeks or 24 meeting. For the data, retrieval is done by MFT test, heart rate recovery test, and skinfold thickness test. Furthermore, the result was analyzed by using SPSS 21 series. In conclusion, significant effect of high-impact aerobics and Zumba fitness on increasing VO2Max, heart rate recovery, skinfold thickness.

  16. Effect of injected rotenone on the production and composition of urine from the rainbow trout (Salmo gairdneri)

    USGS Publications Warehouse

    Erickson, D.A.; Gingerich, W.H.

    1986-01-01

    Renal function was evaluated in adult rainbow trout (Salmo gairdneri) dosed i.a. with rotenone at 225 and 275 μg/kg. The chemical composition of urine samples and urine flow rates collected over a 5-h pretreatment period were compared with hourly urine samples collected over a 5-h posttreatment period. Significant increases in osmolality and in concentrations of sodium, potassium, chloride, glucose, and total protein were observed in the urine of treated fish. Urine solute concentrations reached maximum values within 1 to 3 h after treatment and decreased thereafter, indicating that the effects were reversible. Concentrations of sodium and chloride were highly correlated in 2-h posttreatment urine samples at the low (r = 0.922) and high (r = 0.981) rotenone treatments. Urine flow rates were reduced in trout at each dose of rotenone but the decrease in volume of urine voided was not dose-dependent. In a separate study, [14C]polyethylene glycol was used as a filtration marker to determine the effect of rotenone treatment (225 &mu:g/kg) on urine flow rate, glomerular filtration rate, and renal water reabsorption. We showed that posttreatment urine flow rates were reduced partly by reduced glomerular filtration and partly by increased water reabsorption. Transient increases in plasma osmolality and hematocrit also were observed 0.5 h after rotenone treatment.

  17. Methane Cycling in a Warming Wetland

    NASA Astrophysics Data System (ADS)

    Noyce, G. L.; Megonigal, P.; Rich, R.; Kirwan, M. L.; Herbert, E. R.

    2017-12-01

    Coastal wetlands are global hotspots of carbon (C) storage, but the future of these systems is uncertain. In June 2016, we initiated an in-situ, active, whole-ecosystem warming experiment in the Smithsonian's Global Change Research Wetland to quantify how warming and elevated CO2 affect the stability of coastal wetland soil C pools and contemporary rates of C sequestration. Transects are located in two plant communities, dominated by C3 sedges or C4 grasses. The experiment has a gradient design with air and soil warming treatments ranging from ambient to +5.1 °C and heated plots consistently maintain their target temperature year-round. In April 2017, an elevated CO2 treatment was crossed with temperature in the C3community. Ongoing measurements include soil elevation, C fluxes, porewater chemistry and redox potential, and above- and below-ground growth and biomass. In both years, warming increased methane (CH4) emissions (measured at 3-4 week intervals) from spring through fall at the C3 site, but had little effect on emissions from the C4 site. Winter (Dec-Mar) emissions showed no treatment effect. Stable isotope analysis of dissolved CH4 and DIC also indicated that warming had differing effects on CH4 pathways in the two vegetation communities. To better understand temperature effects on rates of CH4 production and oxidation, 1 m soil cores were collected from control areas of the marsh in summer 2017 and incubated at temperatures ranging from 4 °C to 35 °C. Warming increased CH4 production and oxidation rates in surface samples and oxidation rates in the rooting zone samples from both sites, but temperature responses in deep (1 m) soil samples were minimal. In the surface and rooting zone samples, production rates were also consistently higher in C3 soils compared to C4 soils, but, contrary to our expectations, the temperature response was stronger in the C4 soils. However, oxidation in C3 rooting zone samples did have a strong temperature response. The ratio of CO2:CH4 decreased with increasing temperature in surface samples from both sites, indicating that anaerobic respiration in surface soil may become increasingly methanogenic with warming. In contrast, the rooting zone and deep soil samples showed the opposite trend, again suggesting that the soil profile will not respond consistently to warming.

  18. [Self-sampling and reminder letters increase participation in the Finnish cervical cancer screening programme].

    PubMed

    Virtanen, Anni; Nieminen, Pekka; Malila, Nea; Luostarinen, Tapio; Anttila, Ahti

    2013-01-01

    Participation rate in the national cervical cancer screening programme is currently less than 70% in Finland. A new potential method of increasing the attendance are self-taken samples for hrHPV-testing. All cervical cancer screening non-attendees in 22 municipalities received first a reminder letter. Non-attendees after the reminder letter were offered a self-sampling device. Reminder letters increased total participation from 72.6% to 79.9%, and self-sampling tests further to 83.4%. If reminder letters were sent with fixed appointments, participation was significantly higher (30 vs. 14%). If self-sampling is used after the recommended two invitations, overall screening attendance could reach the desired 80% to 85%.

  19. Factors Impacting Online Ratings for Otolaryngologists.

    PubMed

    Calixto, Nathaniel E; Chiao, Whitney; Durr, Megan L; Jiang, Nancy

    2018-06-01

    To identify factors associated with online patient ratings and comments for a nationwide sample of otolaryngologists. Ratings, demographic information, and written comments were obtained for a random sample of otolaryngologists from HealthGrades.com and Vitals.com . Online Presence Score (OPS) was based on 10 criteria, including professional website and social media profiles. Regression analyses identified factors associated with increased rating. We evaluated for correlations between OPS and other attributes with star rating and used chi-square tests to evaluate content differences between positive and negative comments. On linear regression, increased OPS was associated with higher ratings on HealthGrades and Vitals; higher ratings were also associated with younger age on Vitals and less experience on HealthGrades. However, detailed correlation studies showed weak correlation between OPS and rating; age and graduation year also showed low correlation with ratings. Negative comments more likely focused on surgeon-independent factors or poor bedside manner. Though younger otolaryngologists with greater online presence tend to have higher ratings, weak correlations suggest that age and online presence have only a small impact on the content found on ratings websites. While most written comments are positive, deficiencies in bedside manner or other physician-independent factors tend to elicit negative comments.

  20. Effective combined water and sideband suppression for low-speed tissue and in vivo MAS NMR.

    PubMed

    Mobarhan, Yalda Liaghati; Struppe, Jochem; Fortier-McGill, Blythe; Simpson, André J

    2017-08-01

    High-resolution magic angle spinning (HR-MAS) NMR is a powerful technique that can provide metabolic profiles and structural constraints on intact biological and environmental samples such as cells, tissues and living organisms. However, centripetal force from fast spinning can lead to a loss of sample integrity. In analyses focusing on structural organization, metabolite compartmentalization or in vivo studies, it is critical to keep the sample intact. As such, there is growing interest in slow spinning studies that preserve sample longevity. In this study, for example, reducing the spinning rate from 2500 to 500 Hz during the analysis of a living freshwater shrimp increased the 100% survivability threshold from ~14 to 40 h. Unfortunately, reducing spinning rate decreases the intensity of the isotropic signals and increases both the intensity and number of spinning sidebands, which mask spectral information. Interestingly, water suppression approaches such as excitation sculpting and W5 WATERGATE, which are effective at higher spinning rates, fail at lower spinning rates (<2500 Hz) while simpler approaches such as presaturation are not able to effectively suppress water when the ratio of water to biomass is very high, as is the case in vivo. As such there is a considerable gap in NMR approaches which can be used to suppress water signals and sidebands in biological samples at lower spinning rates. This research presents simple but practically important sequences that combine PURGE water suppression with both phase-adjusted spinning sidebands and an analogue of TOSS termed TOSS.243. The result is simple and effective water and sideband suppression even in extremely dilute samples in pure water down to ~100 Hz spinning rate. The approach is introduced, described and applied to a range of samples including, ex vivo worm tissue, Daphnia magna (water fleas), and in vivo Hyalella azteca (shrimp).

  1. Determination of the effect of brand and product identification on consumer palatability ratings of ground beef patties.

    PubMed

    Wilfong, A K; McKillip, K V; Gonzalez, J M; Houser, T A; Unruh, J A; Boyle, E A E; O'Quinn, T G

    2016-11-01

    The objective of this study was to determine the effect of brand and product identification on consumer palatability ratings of ground beef patties. Six treatments were used in the study: 90/10 Certified Angus Beef (CAB) ground sirloin, 90/10 ground beef, 80/20 CAB ground chuck, 80/20 ground chuck, 80/20 ground beef, and 73/27 CAB ground beef. Ground beef was processed into 151.2-g patties using a patty former with 2 consecutively formed patties assigned to blind consumer testing and the following 2 assigned to informed testing. Following cooking to 74°C, patties were cut into quarters and served to consumers. Consumers ( = 112) evaluated samples in 2 rounds for tenderness, juiciness, flavor liking, texture liking, and overall liking. Each trait was also rated as either acceptable or unacceptable. In the first round of testing, samples were blind evaluated, with no information about the treatments provided to consumers, but in the second round, product type and brand were disclosed prior to sample evaluation. Additionally, texture profile and shear force analyses were performed on patties from each treatment. Few differences were observed for palatability traits during blind consumer testing; however, during informed testing, 90/10 CAB ground sirloin was rated greatest ( < 0.05) for all palatability traits other than juiciness. Also, 90/10 CAB ground sirloin had increased ( < 0.05; (consumer informed score - consumer blind score)/consumer blind score) ratings for tenderness (17.4%), juiciness (36.5%), flavor liking (23.3%), texture liking (18.2%), and overall liking (24.7%) due to brand disclosure. Increased ( < 0.05) ratings were found for CAB products for multiple traits due to treatment disclosure, whereas the only non-CAB-branded product that received increased ( < 0.05) ratings during informed testing was 90/10 ground beef for tenderness and juiciness. Texture results indicated that decreased fat level increased hardness, cohesiveness, gumminess, and chewiness. These results indicate that when sampling ground beef without brand and product information, few consumers find differences in eating quality among ground beef treatments; however, when consumers are aware of the brand, fat level, and subprimal blend prior to sampling, these factors have a large impact on consumer eating satisfaction.

  2. Discrepancies between self- and adult-perceptions of social competence in children with neuropsychiatric disorders.

    PubMed

    Vuori, M; Autti-Rämö, I; Junttila, N; Vauras, M; Tuulio-Henriksson, A

    2017-09-01

    The present study examines discrepancies between self- and adult-perceptions of social competence in children with attention deficit-hyperactivity disorder (ADHD), autism spectrum disorders (ASD) and possible co-morbid disruptive behaviour disorders (DBD). Self-reported questionnaires were collected from multiple informants at the baseline of a multi-systemic family intervention programme for children (aged 5-12) with ADHD, ASD and possible co-morbid DBD. In total, out of the 154 families eligible for the study, information was received concerning children from 124 families (children n = 121; mothers n = 117; fathers n = 86; teachers n = 97). In addition to this, a comparison community sample of 318 school-aged children (approximately 10 years old) was utilized to examine the perceptions of children's social competence across intervention and population groups in more detail. Children's self-perceptions in the prosocial dimension of social competence (i.e. cooperating skills, empathy) did not differ between the intervention and comparison groups. Interestingly, the children in the intervention sample expressed more impulsivity and disruptiveness - the antisocial dimension of social competence - when compared with the children in the comparison sample. Adult ratings demonstrated that mothers, fathers and teachers reported decreased prosocial behaviour and increased antisocial behaviour across overall dimensions and sub-dimensions when compared with adults' ratings of elementary school children. Informant discrepancies between self-ratings and adult ratings across intervention groups yielded significant effect sizes (eta-squared) across all domains of social competence ranging from .09 to .25. Children's positive self-ratings of social competence relative to adult ratings increased within intervention sample when compared with population sample. The intervention sample children appeared to acknowledge their social competence deficits, yet self-perceptions were inflated relative to adult ratings when focusing on peer relationship difficulties, particularly, aggression to peers. © 2016 John Wiley & Sons Ltd.

  3. Estimating pesticide sampling rates by the polar organic chemical integrative sampler (POCIS) in the presence of natural organic matter and varying hydrodynamic conditions

    USGS Publications Warehouse

    Charlestra, Lucner; Amirbahman, Aria; Courtemanch, David L.; Alvarez, David A.; Patterson, Howard

    2012-01-01

    The polar organic chemical integrative sampler (POCIS) was calibrated to monitor pesticides in water under controlled laboratory conditions. The effect of natural organic matter (NOM) on the sampling rates (Rs) was evaluated in microcosms containing -1 of total organic carbon (TOC). The effect of hydrodynamics was studied by comparing Rs values measured in stirred (SBE) and quiescent (QBE) batch experiments and a flow-through system (FTS). The level of NOM in the water used in these experiments had no effect on the magnitude of the pesticide sampling rates (p > 0.05). However, flow velocity and turbulence significantly increased the sampling rates of the pesticides in the FTS and SBE compared to the QBE (p < 0.001). The calibration data generated can be used to derive pesticide concentrations in water from POCIS deployed in stagnant and turbulent environmental systems without correction for NOM.

  4. Acoustic emission strand burning technique for motor burning rate prediction

    NASA Technical Reports Server (NTRS)

    Christensen, W. N.

    1978-01-01

    An acoustic emission (AE) method is being used to measure the burning rate of solid propellant strands. This method has a precision of 0.5% and excellent burning rate correlation with both subscale and large rocket motors. The AE procedure burns the sample under water and measures the burning rate from the acoustic output. The acoustic signal provides a continuous readout during testing, which allows complete data analysis rather than the start-stop clockwires used by the conventional method. The AE method helps eliminate such problems as inhibiting the sample, pressure increase and temperature rise, during testing.

  5. Does increasing the size of bi-weekly samples of records influence results when using the Global Trigger Tool? An observational study of retrospective record reviews of two different sample sizes.

    PubMed

    Mevik, Kjersti; Griffin, Frances A; Hansen, Tonje E; Deilkås, Ellen T; Vonen, Barthold

    2016-04-25

    To investigate the impact of increasing sample of records reviewed bi-weekly with the Global Trigger Tool method to identify adverse events in hospitalised patients. Retrospective observational study. A Norwegian 524-bed general hospital trust. 1920 medical records selected from 1 January to 31 December 2010. Rate, type and severity of adverse events identified in two different samples sizes of records selected as 10 and 70 records, bi-weekly. In the large sample, 1.45 (95% CI 1.07 to 1.97) times more adverse events per 1000 patient days (39.3 adverse events/1000 patient days) were identified than in the small sample (27.2 adverse events/1000 patient days). Hospital-acquired infections were the most common category of adverse events in both the samples, and the distributions of the other categories of adverse events did not differ significantly between the samples. The distribution of severity level of adverse events did not differ between the samples. The findings suggest that while the distribution of categories and severity are not dependent on the sample size, the rate of adverse events is. Further studies are needed to conclude if the optimal sample size may need to be adjusted based on the hospital size in order to detect a more accurate rate of adverse events. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. Association between thermal environment and Salmonella in fecal samples from dairy cattle in midwestern United States

    PubMed Central

    Likavec, Tasha; Pires, Alda F.A.; Funk, Julie A.

    2016-01-01

    The objective of this study was to describe the association between thermal measures in the barn environment (pen temperature and humidity) and fecal shedding of Salmonella in dairy cattle. A repeated cross-sectional study was conducted within a commercial dairy herd located in the midwestern United States. Five pooled fecal samples were collected monthly from each pen for 9 mo and submitted for microbiological culture. Negative binomial regression methods were used to test the association [incidence rate ratio (IRR)] between Salmonella pen status (the count of Salmonella-positive pools) and thermal environmental parameters [average temperature and temperature humidity index (THI)] for 3 time periods (48 h, 72 h, and 1 wk) before fecal sampling. Salmonella was cultured from 10.8% [39/360; 95% confidence interval (CI): 7.8% to 14.5%] of pooled samples. The highest proportion of positive pools occurred in August. The IRR ranged from 1.26 (95% CI: 1.15 to 1.39, THI 1 wk) to 4.5 (95% CI: 2.13 to 9.51, heat exposure 1 wk) across all thermal parameters and lag time periods measured. For example, the incidence rate of Salmonella-positive pools increased by 54% for every 5°C increment in average temperature (IRR = 1.54; 95% CI: 1.29 to 1.85) and 29% for every 5-unit increase in THI (IRR = 1.29; 95% CI: 1.16 to 1.42) during the 72 h before sampling. The incidence rate ratio for pens exposed to higher temperatures (> 25°C) was 4.5 times (95% CI: 2.13 to 9.51) the incidence rate ratio for pens exposed to temperatures < 25°C in the 72 h before sampling. Likewise, the incidence rate ratio for pens exposed to THI > 70 was 4.23 times greater (95% CI: 2.1 to 8.28) than when the THI was < 70 in the 72 h before sampling. An association was found between the thermal environment and Salmonella shedding in dairy cattle. Further research is warranted in order to fully understand the component risks associated with the summer season and increased Salmonella shedding. PMID:27408330

  7. Arc Inception Mechanism on a Solar Array Immersed in a Low-Density Plasma

    NASA Technical Reports Server (NTRS)

    Vayner, B.; Galofaro, J.; Ferguson, D.

    2001-01-01

    In this report, results are presented of an experimental and theoretical study of arc phenomena and snapover for two samples of solar arrays immersed in argon plasma. The effects of arcing and snapover are investigated. I-V curves are measured, and arc and snapover inception voltages and arc rates are determined within the wide range of plasma parameters. A considerable increase in arc rate due to absorption of molecules from atmospheric air has been confirmed. It is shown that increasing gas pressure causes increasing ion current collection and, consequently, arc rate even though the effect of conditioning also takes place. Arc sites have been determined by employing a video-camera. It is confirmed that keeping sample under high vacuum for a long time results in shifting arc threshold voltage well below -300 V. The results obtained seem to be important for the understanding of arc inception mechanism.

  8. A fluid response: Alpha-amylase reactions to acute laboratory stress are related to sample timing and saliva flow rate.

    PubMed

    Nagy, Tamás; van Lien, René; Willemsen, Gonneke; Proctor, Gordon; Efting, Marieke; Fülöp, Márta; Bárdos, György; Veerman, Enno C I; Bosch, Jos A

    2015-07-01

    Salivary alpha-amylase (sAA) is used as a sympathetic (SNS) stress marker, though its release is likely co-determined by SNS and parasympathetic (PNS) activation. The SNS and PNS show asynchronous changes during acute stressors, and sAA responses may thus vary with sample timing. Thirty-four participants underwent an eight-minute memory task (MT) and cold pressor task (CPT). Cardiovascular SNS (pre-ejection period, blood pressure) and PNS (heart rate variability) activity were monitored continuously. Unstimulated saliva was collected repeatedly during and after each laboratory stressor, and sAA concentration (U/ml) and secretion (U/minute) determined. Both stressors increased anxiety. The MT caused an immediate and continued cardiac SNS activation, but sAA concentration increased at task cessation only (+54%); i.e., when there was SNS-PNS co-activation. During the MT sAA secretion even decreased (-35%) in conjunction with flow rate and vagal tone. The CPT robustly increased blood pressure but not sAA. In summary, sAA fluctuations did not parallel changes in cardiac SNS activity or anxiety. sAA responses seem contingent on sample timing and flow rate, likely involving both SNS and PNS influences. Verification using other stressors and contexts seems warranted. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. The Effect of Trace H2O on the Mechanisms of the Olivine-Ringwoodite Transformation

    NASA Astrophysics Data System (ADS)

    Sharp, T. G.; Rieck, K. D.; Hu, J.; Du Frane, W. L.

    2011-12-01

    The existence of metastable olivine has been inferred as a possible trigger of deep focus earthquakes. Because hydrogen increases olivine-ringwoodite transformation rates, the existence of metastable olivine in the transition would require the subduction of very dry olivine. Our previous work has shown that for San Carlos olivine spheres, hydrated in a piston cylinder with 75 ppm H2O and 300 ppm D2O, ringwoodite-rim growth rates are greatly enhanced relative to anhydrous samples (Du Frane2010 and Diedrich et al, 2009). In anhydrous samples, rim-growth rates decrease with time as elastic strain builds up in the system, eventually stopping the reaction. As strain increases, wadsleyite forms, rather than or in addition to ringwoodite. In hydrous samples, hydrogen partitions to the ringwoodite growth rim, hydrolytically weakening it, and preventing the build up of elastic strain energy. Eventually, elastic strain energy may build up in slightly hydrous samples if the hydrogen content of the rim decreases sufficiently. Here we investigate the transformation mechanisms in the same San Carlos olivine samples, hydrated to 75 and 300 ppm H2O and D2O and transformed at 18 GPa. A 75-ppm-H2O sample run at 1100°C for 40 minutes shows a complex mixture of reaction textures. Optical microscopy and Raman spectroscopy show that the ringwoodite rims are nearly pure ringwoodite with minor amounts of wadsleyite. Scanning electron microscopy and transmission electron microscopy on a Focused Ion Beam slices of this sample show that the outermost rim is uniform, relatively course grained and defect free ringwoodite. This suggests limited nucleation at the sample-capsule interface and fairly rapid incoherent growth. The inner rim consists of a complex mixture of olivine and ringwoodite in which most of the ringwoodite has no crystallographic relationship to the host olivine and therefore represents incoherent nucleation and growth. Coherent ringwoodite lamellae are also present in the inner rim and the olivine core. These have the same crystallographic relation to olivine ([001]Ol || <110>Rg and (100)Ol || {111}Rw) as seen in previous studies (Kershhofer et al 1996). In the core of the olivine spheres, backscatter electron images show thin ringwoodite lamellae and numerous ringwoodite inclusions that are presumably incoherent. Unlike anhydrous samples, which generally contain wadsleyite inclusions, our Raman data indicate that hydrous samples have little intra-crystalline wadsleyite. Some of the ringwoodite inclusions are grouped into linear arrays that suggest heterogeneous nucleation on pre-existing defects such as tilt boundaries. The presence of 75 ppm H2O appears to enhance heterogeneous nucleation and the growth rates of coherent lamellae and incoherent inclusions. These results imply that small amounts of H2O in olivine enhance the transition to ringwoodite by increasing intra-crystalline nucleation and growth rates as well as by increasing rim-growth rates.

  10. Reversible amorphous-crystalline phase changes in a wide range of Se1-xTex alloys studied using ultrafast differential scanning calorimetry

    NASA Astrophysics Data System (ADS)

    Vermeulen, Paul. A.; Momand, Jamo; Kooi, Bart J.

    2014-07-01

    The reversible amorphous-crystalline phase change in a chalcogenide material, specifically the Se1-xTex alloy, has been investigated for the first time using ultrafast differential scanning calorimetry. Heating rates and cooling rates up to 5000 K/s were used. Repeated reversible amorphous-crystalline phase switching was achieved by consecutively melting, melt-quenching, and recrystallizing upon heating. Using a well-conditioned method, the composition of a single sample was allowed to shift slowly from 15 at. %Te to 60 at. %Te, eliminating sample-to-sample variability from the measurements. Using Energy Dispersive X-ray Spectroscopy composition analysis, the onset of melting for different Te-concentrations was confirmed to coincide with the literature solidus line, validating the use of the onset of melting Tm as a composition indicator. The glass transition Tg and crystallization temperature Tc could be determined accurately, allowing the construction of extended phase diagrams. It was found that Tm and Tg increase (but Tg/Tm decrease slightly) with increasing Te-concentration. Contrarily, the Tc decreases substantially, indicating that the amorphous phase becomes progressively unfavorable. This coincides well with the observation that the critical quench rate to prevent crystallization increases about three orders of magnitude with increasing Te concentration. Due to the employment of a large range of heating rates, non-Arrhenius behavior was detected, indicating that the undercooled liquid SeTe is a fragile liquid. The activation energy of crystallization was found to increase 0.5-0.6 eV when the Te concentration increases from 15 to 30 at. % Te, but it ceases to increase when approaching 50 at. % Te.

  11. Design and characterization of thick InxGa1-xAs metamorphic buffer layers grown by hydride vapor phase epitaxy

    NASA Astrophysics Data System (ADS)

    Schulte, K. L.; Zutter, B. T.; Wood, A. W.; Babcock, S. E.; Kuech, T. F.

    2014-03-01

    Thick InxGa1-xAs metamorphic buffer layers (MBLs) grown by hydride vapor phase epitaxy (HVPE) were studied. Relationships between MBL properties and growth parameters such as grading rate, cap layer thickness, final xInAs, and deposition temperature (TD) were explored. The MBLs were characterized by measurement of in-plane residual strain (ɛ¦¦), surface etch pit density (EPD), and surface roughness. Capping layer thickness had a strong effect on strain relaxation, with thickly capped samples exhibiting the lowest ɛ¦¦. EPD was higher in samples with thicker caps, reflecting their increased relaxation through dislocation generation. ɛ¦¦ and EPD were weakly affected by the grading rate, making capping layer thickness the primary structural parameter which controls these properties. MBLs graded in discrete steps had similar properties to MBLs with continuous grading. In samples with identical thickness and 10-step grading style, ɛ¦¦ increased almost linearly with final xInAs, while total relaxation stayed relatively constant. Relaxation as a function of xInAs could be described by an equilibrium model in which dislocation nucleation is impeded by the energy of the existing dislocation array. EPD was constant from xInAs = 0 to 0.24 then increased exponentially, which is related to the increased dislocation interaction and blocking seen at higher dislocation densities. RMS roughness increased with xInAs above a certain strain rate (0.15%/µm) samples grown below this level possessed large surface hillocks and high roughness values. The elimination of hillocks at higher values of xInAs is attributed to increased density of surface steps and is related to the out-of-plane component of the burgers vector of the dominant type of 60° dislocation. TD did not affect ɛ¦¦ for samples with a given xInAs. EPD tended to increase with TD, indicating dislocation glide likely is impeded at higher temperatures.

  12. Overuse Injury Assessment Model

    DTIC Science & Technology

    2007-08-01

    and reduce injuries is a continual challenge. Military researchers face challenges to develop better equipment, improve training regimens, and...performed and calculate biomechanical metrics for each activity. Hardware Challenges • Sampling the sensors sufficiently fast • Having adequate bandwidth...second is that the injury rate increases rapidly initially and, third, that the injury rate continues to climb as the cumulative distance increases

  13. Improved technical success and radiation safety of adrenal vein sampling using rapid, semi-quantitative point-of-care cortisol measurement.

    PubMed

    Page, Michael M; Taranto, Mario; Ramsay, Duncan; van Schie, Greg; Glendenning, Paul; Gillett, Melissa J; Vasikaran, Samuel D

    2018-01-01

    Objective Primary aldosteronism is a curable cause of hypertension which can be treated surgically or medically depending on the findings of adrenal vein sampling studies. Adrenal vein sampling studies are technically demanding with a high failure rate in many centres. The use of intraprocedural cortisol measurement could improve the success rates of adrenal vein sampling but may be impracticable due to cost and effects on procedural duration. Design Retrospective review of the results of adrenal vein sampling procedures since commencement of point-of-care cortisol measurement using a novel single-use semi-quantitative measuring device for cortisol, the adrenal vein sampling Accuracy Kit. Success rate and complications of adrenal vein sampling procedures before and after use of the adrenal vein sampling Accuracy Kit. Routine use of the adrenal vein sampling Accuracy Kit device for intraprocedural measurement of cortisol commenced in 2016. Results Technical success rate of adrenal vein sampling increased from 63% of 99 procedures to 90% of 48 procedures ( P = 0.0007) after implementation of the adrenal vein sampling Accuracy Kit. Failure of right adrenal vein cannulation was the main reason for an unsuccessful study. Radiation dose decreased from 34.2 Gy.cm 2 (interquartile range, 15.8-85.9) to 15.7 Gy.cm 2 (6.9-47.3) ( P = 0.009). No complications were noted, and implementation costs were minimal. Conclusions Point-of-care cortisol measurement during adrenal vein sampling improved cannulation success rates and reduced radiation exposure. The use of the adrenal vein sampling Accuracy Kit is now standard practice at our centre.

  14. Aedes aegypti (L.) and Aedes polynesiensis Marks (Diptera: Culicidae) in Moorea, French Polynesia: a study of adult population structures and pathogen (Wuchereria bancrofti and Dirofilaria immitis) infection rates to indicate regional and seasonal epidemiological risk for dengue and filariasis.

    PubMed

    Russell, Richard C; Webb, Cameron E; Davies, Neil

    2005-11-01

    Populations of Aedes aegypti (L.) and Aedes polynesiensis (Marks) on Moorea Island, French Polynesia, the local vectors of dengue and filariasis, respectively, were sampled by landing/biting collection at nine localities on the east, north, and west coasts, during the late dry season, early and late wet season (September-May) 2003 and 2004, to investigate epidemiologically important features of the populations and compare them between regions and months. Biting rates of both species tended to increase (but not always significantly) for each species in each region each month from the late dry season to the late wet season, and the north coast region had significantly higher biting rates of Ae. aegypti. Insemination rates of Ae. polynesiensis females (94.5-98.8%) were consistently greater than those of Ae. aegypti (87.5-93.5%) throughout the study, but there was no significant difference in the insemination rates of either species between months and regions. Parity rates were generally highest in north coast samples and lowest in west coast samples for both species and generally increased (albeit not always significantly) by month for each species, with a range of 52.9-88.8% for Ae. polynesiensis and 28.6-53.6% for Ae. aegypti, although the high gravid rate (15.8-45.9%) of Ae. aegypti samples (reflecting its feeding more than once in a gonotrophic cycle) confounded both intraspecific and interspecific comparisons. Filarial infection was rare in Ae. aegypti, although both W. bancrofti and D. immitis were recorded, and infection rates in Ae. polynesiensis increased through the study period in each region for both filarias, with up to 4.6% infected and 1.4% infective for W. bancrofti and up to 6.3% infected and 2.5% infective for D. immitis. For W. bancrofti, infection rates were significantly lower on the west coast and also in the dry season, whereas rates for infective stages were significantly greater in the late wet season. For D. immitis there was no significant difference in infection rates between regions, but rates were significantly greater in the late wet season. Rainfall in all months sustains populations of both vectors and explains the relatively few significant differences between seasons; however, the wet season may provide for increased vector abundance and longevity, and present a potentially increased risk for transmission. Although the differences shown between regions also were limited in a statistical sense, there were increased risks for the northern and eastern regions, where both locals and tourists are concentrated and where the seaports and airport are located, and these areas should be priority targets for disease surveillance and vector control.

  15. A preprocessor for the Urbana coherent-scatter radar

    NASA Technical Reports Server (NTRS)

    Zendt, F. T.; Bowhill, S. A.

    1982-01-01

    The design, interfacing, testing, and operation of a preprocessor to increase the altitude and temporal resolution of the present coherent-scatter system are described. This system upgrade requires an increase in the data collection rate. Replacing the present, relatively slow, ADC with two high speed ADCs achieves the increased echo sampling rate desired. To stay within the capabilities of the main computer's I/O and processing rate the data must be reduced before transfer to the main computer. Thus the preprocessor also coherently integrates the data before transfer.

  16. Shock Response of Commercial Purity Polycrystalline Magnesium Under Uniaxial Strain at Elevated Temperatures

    NASA Astrophysics Data System (ADS)

    Wang, Tianxue; Zuanetti, Bryan; Prakash, Vikas

    2017-12-01

    In the present paper, results of plate impact experiments designed to investigate the onset of incipient plasticity in commercial purity polycrystalline magnesium (99.9%) under weak uniaxial strain compression and elevated temperatures up to melt are presented. The dynamic stress at yield and post yield of magnesium, as inferred from the measured normal component of the particle velocity histories at the free (rear) surface of the target plate, are observed to decrease progressively with increasing test temperatures in the range from 23 to 500 °C. At (higher) test temperatures in the range 500-610 °C, the rate of decrease of dynamic stress with temperature at yield and post-yield in the sample is observed to weaken. At still higher test temperatures (617 and 630 °C), a dramatic increase in dynamic yield as well as flow stress is observed indicating a change in dominant mechanism of plastic deformation as the sample approaches the melt point of magnesium at strain rates of 105/s. In addition to these measurements at the wavefront, the plateau region of the free surface particle velocity profiles indicates that the longitudinal (plastic) impedance of the magnesium samples decreases continuously as the sample temperatures are increased from room to 610 °C, and then reverses trend (indicating increasing material longitudinal impedance/strength) as the sample temperatures are increased to 617 and 630 °C. Electron back scattered diffraction analysis of the as-received and annealed pre-test magnesium samples reveal grain coarsening as well as grain re-orientation to a different texture during the heating process of the samples.

  17. Design of a Single Channel Modulated Wideband Converter for Wideband Spectrum Sensing: Theory, Architecture and Hardware Implementation

    PubMed Central

    Liu, Weisong; Huang, Zhitao; Wang, Xiang; Sun, Weichao

    2017-01-01

    In a cognitive radio sensor network (CRSN), wideband spectrum sensing devices which aims to effectively exploit temporarily vacant spectrum intervals as soon as possible are of great importance. However, the challenge of increasingly high signal frequency and wide bandwidth requires an extremely high sampling rate which may exceed today’s best analog-to-digital converters (ADCs) front-end bandwidth. Recently, the newly proposed architecture called modulated wideband converter (MWC), is an attractive analog compressed sensing technique that can highly reduce the sampling rate. However, the MWC has high hardware complexity owing to its parallel channel structure especially when the number of signals increases. In this paper, we propose a single channel modulated wideband converter (SCMWC) scheme for spectrum sensing of band-limited wide-sense stationary (WSS) signals. With one antenna or sensor, this scheme can save not only sampling rate but also hardware complexity. We then present a new, SCMWC based, single node CR prototype System, on which the spectrum sensing algorithm was tested. Experiments on our hardware prototype show that the proposed architecture leads to successful spectrum sensing. And the total sampling rate as well as hardware size is only one channel’s consumption of MWC. PMID:28471410

  18. Pregnancy rates after artificial insemination with cooled stallion spermatozoa either with or without single layer centrifugation.

    PubMed

    Morrell, J M; Richter, J; Martinsson, G; Stuhtmann, G; Hoogewijs, M; Roels, K; Dalin, A-M

    2014-11-01

    A successful outcome after artificial insemination with cooled semen is dependent on many factors, the sperm quality of the ejaculate being one. Previous studies have shown that spermatozoa with good motility, normal morphology, and good chromatin integrity can be selected by means of colloid centrifugation, particularly single layer centrifugation (SLC) using species-specific colloids. The purpose of the present study was to conduct an insemination trial with spermatozoa from "normal" ejaculates, i.e., from stallions with no known fertility problem, to determine whether the improvements in sperm quality seen in SLC-selected sperm samples compared with uncentrifuged controls in laboratory tests are reflected in an increased pregnancy rate after artificial insemination. In a multicentre study, SLC-selected sperm samples and uncentrifuged controls from eight stallions were inseminated into approximately 10 mares per treatment per stallion. Ultrasound examination was carried out approximately 16 days after insemination to detect an embryonic vesicle. The pregnancy rates per cycle were 45% for controls and 69% for SLC-selected sperm samples, which is statistically significant (P < 0.0018). Thus, the improvement in sperm quality reported previously for SLC-selected sperm samples is associated with an increase in pregnancy rate, even for ejaculates from stallions with no known fertility problem. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. A neural algorithm for the non-uniform and adaptive sampling of biomedical data.

    PubMed

    Mesin, Luca

    2016-04-01

    Body sensors are finding increasing applications in the self-monitoring for health-care and in the remote surveillance of sensitive people. The physiological data to be sampled can be non-stationary, with bursts of high amplitude and frequency content providing most information. Such data could be sampled efficiently with a non-uniform schedule that increases the sampling rate only during activity bursts. A real time and adaptive algorithm is proposed to select the sampling rate, in order to reduce the number of measured samples, but still recording the main information. The algorithm is based on a neural network which predicts the subsequent samples and their uncertainties, requiring a measurement only when the risk of the prediction is larger than a selectable threshold. Four examples of application to biomedical data are discussed: electromyogram, electrocardiogram, electroencephalogram, and body acceleration. Sampling rates are reduced under the Nyquist limit, still preserving an accurate representation of the data and of their power spectral densities (PSD). For example, sampling at 60% of the Nyquist frequency, the percentage average rectified errors in estimating the signals are on the order of 10% and the PSD is fairly represented, until the highest frequencies. The method outperforms both uniform sampling and compressive sensing applied to the same data. The discussed method allows to go beyond Nyquist limit, still preserving the information content of non-stationary biomedical signals. It could find applications in body sensor networks to lower the number of wireless communications (saving sensor power) and to reduce the occupation of memory. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. [Detection of Avian Influenza Virus in Environmental Samples Collected from Live Poultry Markets in China during 2009-2013].

    PubMed

    Zhang, Ye; Li, Xiaodan; Zou, Shumei; Bo, Hong; Dong, Libo; Gao, Rongbao; Wang, Dayan; Shu, Yuelong

    2015-11-01

    Abstract: To investigate the distribution of avian influenza virus in environmental samples from live poultry markets (LPM) in China, samples were collected and tested by nucleic acid during 2009-2013 season. Each sample was tested by real-time RT PCR using flu A specific primers. If any real-time PCR was positive, the sample was inoculated into specific-pathogen-free (SPF) embryonated chicken eggs for viral isolation. The results indicated that the positive rate of nucleic acid in enviromental samples exhibited seasonality. The positive rate of nucleic acid was significantly higher in Winter and Spring. The positive rate of nucleic acid in LPM located in the south of China was higher than in northern China. Samples of Sewage for cleaning poultry and chopping board showed that higher positive rate of nucleic acid than other samples. The Subtype identification showed that H5 and H9 were main subtypes in the enviromental samples. Viral isolation indicated H5 subtypes was more than H9 subtypes between 2009 and 2013 while H9 subtypes increased in 2013. Our findings suggested the significance of public health based on LPM surveillance and provided the basis of prevention and early warning for avian flu infection human.

  1. Influence of homogenization treatment on physicochemical properties and enzymatic hydrolysis rate of pure cellulose fibers.

    PubMed

    Jacquet, N; Vanderghem, C; Danthine, S; Blecker, C; Paquot, M

    2013-02-01

    The aim of this study is to compare the effect of different homogenization treatments on the physicochemical properties and the hydrolysis rate of a pure bleached cellulose. Results obtained show that homogenization treatments improve the enzymatic hydrolysis rate of the cellulose fibers by 25 to 100 %, depending of the homogenization treatment applied. Characterization of the samples showed also that homogenization had an impact on some physicochemical properties of the cellulose. For moderate treatment intensities (pressure below 500 b and degree of homogenization below 25), an increase of water retention values (WRV) that correlated to the increase of the hydrolysis rate was highlighted. Result also showed that the overall crystallinity of the cellulose properties appeared not to be impacted by the homogenization treatment. For higher treatment intensities, homogenized cellulose samples developed a stable tridimentional network that contributes to decrease cellulase mobility and slowdown the hydrolysis process.

  2. Flammability Parameters of Candles

    NASA Astrophysics Data System (ADS)

    Balog, Karol; Kobetičová, Hana; Štefko, Tomáš

    2017-06-01

    The paper deals with the assessment of selected fire safety characteristics of candles. Weight loss of a candle during the burning process, candle burning rate, soot index, heat release rate and yield of carbon oxides were determined. Soot index was determined according to EN 15426: 2007 - Candles - Specification for Sooting Behavior. All samples met the prescribed amount of produced soot. Weight loss, heat release rate and the yield of carbon oxides were determined for one selected sample. While yield of CO increased during the measurement, the yield of CO2 decreased by half in 40 minutes.

  3. Developments in the Frequency of Ratings and Evaluation Tendencies: A Review of German Physician Rating Websites.

    PubMed

    McLennan, Stuart; Strech, Daniel; Reimann, Swantje

    2017-08-25

    Physician rating websites (PRWs) have been developed to allow all patients to rate, comment, and discuss physicians' quality online as a source of information for others searching for a physician. At the beginning of 2010, a sample of 298 randomly selected physicians from the physician associations in Hamburg and Thuringia were searched for on 6 German PRWs to examine the frequency of ratings and evaluation tendencies. The objective of this study was to examine (1) the number of identifiable physicians on German PRWs; (2) the number of rated physicians on German PRWs; (3) the average and maximum number of ratings per physician on German PRWs; (4) the average rating on German PRWs; (5) the website visitor ranking positions of German PRWs; and (6) how these data compare with 2010 results. A random stratified sample of 298 selected physicians from the physician associations in Hamburg and Thuringia was generated. Every selected physician was searched for on the 6 PRWs (Jameda, Imedo, Docinsider, Esando, Topmedic, and Medführer) used in the 2010 study and a PRW, Arztnavigator, launched by Allgemeine Ortskrankenkasse (AOK). The results were as follows: (1) Between 65.1% (194/298) on Imedo to 94.6% (282/298) on AOK-Arztnavigator of the physicians were identified on the selected PRWs. (2) Between 16.4% (49/298) on Esando to 83.2% (248/298) on Jameda of the sample had been rated at least once. (3) The average number of ratings per physician ranged from 1.2 (Esando) to 7.5 (AOK-Arztnavigator). The maximum number of ratings per physician ranged from 3 (Esando) to 115 (Docinsider), indicating an increase compared with the ratings of 2 to 27 in the 2010 study sample. (4) The average converted standardized rating (1=positive, 2=neutral, and 3=negative) ranged from 1.0 (Medführer) to 1.2 (Jameda and Topmedic). (5) Only Jameda (position 317) and Medführer (position 9796) were placed among the top 10,000 visited websites in Germany. Whereas there has been an overall increase in the number of ratings when summing up ratings from all 7 analyzed German PRWs, this represents an average addition of only 4 new ratings per physician in a year. The increase has also not been even across the PRWs, and it would be advisable for the users of PRWs to utilize a number of PRWs to ascertain the rating of any given physician. Further research is needed to identify barriers for patients to rate their physicians and to assist efforts to increase the number of ratings on PRWs to consequently improve the fairness and practical importance of PRWs. ©Stuart McLennan, Daniel Strech, Swantje Reimann. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 25.08.2017.

  4. The Multiphase Rheology of Andesitic Magmas from the 1.9ka Eruption of Turrialba Volcano (Costa Rica)

    NASA Astrophysics Data System (ADS)

    Vona, A.; Di Piazza, A.; Romano, C.; De Astis, G.; Soto, G. J.

    2014-12-01

    We present a study of high-temperature, uniaxial deformation experiments of natural magma from an andesitic eruption of Turrialba volcano (1.9ka Plinian eruption). The aim of this work is to investigate the multiphase rheology (liquid+vesicles+crystals) of natural samples and the effect of vesicles and crystals on the magma viscosity. The experiments were performed using a high-temperature uniaxial Geocomp LoadTrac II press at dry atmospheric conditions and controlled deformation rates. Cores of natural sample (with Φcrys=0.20-0.30 and Φves=0.41-0.58) were deformed isothermally (790-870°C) at variable strain rates (VSR, from 10-6 to 10-4 s-1) and constant strain rate (CSR, 10-5 s-1). VSR were performed at low total amount of strain (e<0.10) to parameterize the flow behavior of these complex natural materials. The stress-strain rate relationships under flow conditions showed a linear trend between the applied stress and strain rate in the temperature interval investigated. All the samples display a steep linear trend, typical of Newtonian fluids (n index ~ 1), with a very small shear thinning behavior. CSR tests were performed at different total amount of strain (e=0.15-0.25-0.35). Strain hardening was observed with increasing deformation, resulting in an increase of apparent viscosity (up to 100.5 Pa s). This increase is related to the loss of total porosity (up to ΔΦves=0.15) due to compaction of the sample as indicated by post-run analyses . The measured multiphase rheology of Turrialba magmas was compared with literature models for both crystal- and bubble-bearing suspension. We calculate a difference of ~101 Pa s in magma apparent viscosity between high and low density samples, that coupled with a lateral temperature gradient inside the conduit of the volcano, could increase up to ~103 Pa s. The large difference in viscosity could be responsible of significant rheological contrasts, possibly resulting in strain localization and brittle fragmentation of magma.

  5. Strain localization and fabric development in polycrystalline anorthite + melt by water diffusion in an axial deformation experiment

    NASA Astrophysics Data System (ADS)

    Fukuda, Jun-ichi; Muto, Jun; Nagahama, Hiroyuki

    2018-01-01

    We performed two axial deformation experiments on synthetic polycrystalline anorthite samples with a grain size of 3 μm and 5 vol% Si-Al-rich glass at 900 °C, a confining pressure of 1.0 GPa, and a strain rate of 10-4.8 s-1. One sample was deformed as-is (dry); in the other sample, two half-cut samples (two cores) with 0.15 wt% water at the boundary were put together in the apparatus. The mechanical data for both samples were essentially identical with a yield strength of 700 MPa and strain weakening of 500 MPa by 20% strain. The dry sample appears to have been deformed by distributed fracturing. Meanwhile, the water-added sample shows plastic strain localization in addition to fracturing and reaction products composed of zoisite grains and SiO2 materials along the boundary between the two sample cores. Infrared spectra of the water-added sample showed dominant water bands of zoisite. The maximum water content was 1500 wt ppm H2O at the two-core boundary, which is the same as the added amount. The water contents gradually decreased from the boundaries to the sample interior, and the gradient fitted well with the solution of the one-dimensional diffusion equation. The determined diffusion coefficient was 7.4 × 10-13 m2/s, which agrees with previous data for the grain boundary diffusion of water. The anorthite grains in the water-added sample showed no crystallographic preferred orientation. Textural observations and water diffusion indicate that water promotes the plastic deformation of polycrystalline anorthite by grain-size-sensitive creep as well as simultaneous reactions. We calculated the strain rate evolution controlled by water diffusion in feldspar aggregates surrounded by a water source. We assumed water diffusion in a dry rock mass with variable sizes. Diffused water weakens a rock mass with time under compressive stress. The calculated strain rate decreased from 10-10 to 10-15 s-1 with an increase in the rock mass size to which water is supplied from < 1 m to 1 km and an increase in the time of water diffusion from < 1 to 10,000 years. This indicates a decrease in the strain rate in a rock mass with increasing deformation via water diffusion.

  6. Study of Evaporation Rate of Water in Hydrophobic Confinement using Forward Flux Sampling

    NASA Astrophysics Data System (ADS)

    Sharma, Sumit; Debenedetti, Pablo G.

    2012-02-01

    Drying of hydrophobic cavities is of interest in understanding biological self assembly, protein stability and opening and closing of ion channels. Liquid-to-vapor transition of water in confinement is associated with large kinetic barriers which preclude its study using conventional simulation techniques. Using forward flux sampling to study the kinetics of the transition between two hydrophobic surfaces, we show that a) the free energy barriers to evaporation scale linearly with the distance between the two surfaces, d; b) the evaporation rates increase as the lateral size of the surfaces, L increases, and c) the transition state to evaporation for sufficiently large L is a cylindrical vapor cavity connecting the two hydrophobic surfaces. Finally, we decouple the effects of confinement geometry and surface chemistry on the evaporation rates.

  7. Quality Improvement Initiative to Improve HPV Vaccine Initiation at Nine Years of Age,.

    PubMed

    Goleman, Martha J; Dolce, Millie; Morack, Jennifer

    2018-05-26

    Adolescent human papillomavirus (HPV) vaccine rates remain low. Early vaccination may improve the efficacy of the vaccine and immunization rates. However, clinicians have not routinely made a strong recommendation to younger adolescents. This study assessed the feasibility of routine vaccination at nine years of age. Three sequential quality improvement (QI) interventions were implemented to shift the initiation of the HPV vaccine to nine years of age in a primary care network in low-income neighborhoods in Columbus, Ohio. The first intervention changed the electronic medical record (EMR) alert for the HPV vaccine from eleven to nine years of age and focused on cancer prevention when discussing the vaccine with families. The second intervention was formation of an HPV QI team. The third intervention was a clinic incentive for HPV captured opportunity rates. Immunization rates were monitored using statistical process control charts to compare the HPV immunization rate in a sample of nine and ten-year-old children with a sample of 11 and 12-year-old children. The percentage of patients receiving an HPV vaccine before 11 years increased from 4.6% to 35.7% during the six months after the QI initiative began and to 60.8% 18 months after the project began. In comparison, the HPV vaccination rate in the sample of 11 and 12 year-olds increased from 78.7% to 82.8% 18 months later. This QI project used multiple interventions to increase HPV vaccination at nine years of age in a large primary care network serving a diverse low-income population. Copyright © 2018. Published by Elsevier Inc.

  8. Increasing the Response Rate of the Patient Satisfaction Survey of Inpatients at National Naval Medical Center

    DTIC Science & Technology

    1993-08-01

    identify a method to improve the effectiveness of the current survey process to increase the response rate of the patients being sampled. As health care... consumer must have adequate representation to provide meaningful information for decision making by the health care organization. Background of the...the Total Quality Management (TQM) philosophy into the health care industry has increased the importance of listening to the customer (Matthews, 1992

  9. Superoxygenated Water as an Experimental Sample for NMR Relaxometry

    ERIC Educational Resources Information Center

    Nestle, Nikolaus; Dakkouri, Marwan; Rauscher, Hubert

    2004-01-01

    The increase in NMR relaxation rates as a result of dissolved paramagnetic species on the sample of superoxygenated drinking water is demonstrated. It is concluded that oxygen content in NMR samples is an important issue and can give rise to various problems in the interpretation of both spectroscopic and NMR imaging or relaxation experiments.

  10. Trends in the incidence of tooth extraction due to periodontal disease: results of a 12-year longitudinal cohort study in South Korea

    PubMed Central

    2017-01-01

    Purpose This study evaluated trends in tooth extraction due to acute and chronic periodontal disease (PD) using data from the National Health Insurance Service-National Sample Cohort for 2002–2013. Methods A random sample of 1,025,340 individuals was selected as a representative sample of the population, and a database (DB) of diagnostic and prescription codes was followed up for 12 years. We used multivariate logistic regression analysis to assess the incidence of total extraction (TE), extraction due to periodontal disease (EPD), and immediate extraction due to periodontal disease (IEPD) according to sociodemographic factors (sex, age, household income, health status, and area of residence). Results The incidence of tooth extraction was found to be increasing, and at a higher rate for TE in PD patients. In 2002, 50.6% of cases of TE were caused by PD, and this increased to 70.8% in 2013, while the number of cases of IEPD increased from 42.8% to 54.9% over the same period. The incidence rates of extraction due to acute and chronic PD increased monotonically. We found that the incidence rates of TE, EPD, and IEPD were all 2-fold higher among patients with high income levels and those who were not beneficiaries of health insurance. Conclusions The rates of TE, EPD, and IEPD have been steadily increasing despite dental healthcare policies to expand public health insurance coverage, increasing the accessibility of dental clinics. Moreover, the effects of these policies were found to vary with both income and education levels. Consistent patient follow-up is required to observe changes in trends regarding tooth extraction according to changes in dental healthcare policies, and meticulous studies of such changes will ensure optimal policy reviews and revisions. PMID:29093985

  11. Estimating genotype error rates from high-coverage next-generation sequence data.

    PubMed

    Wall, Jeffrey D; Tang, Ling Fung; Zerbe, Brandon; Kvale, Mark N; Kwok, Pui-Yan; Schaefer, Catherine; Risch, Neil

    2014-11-01

    Exome and whole-genome sequencing studies are becoming increasingly common, but little is known about the accuracy of the genotype calls made by the commonly used platforms. Here we use replicate high-coverage sequencing of blood and saliva DNA samples from four European-American individuals to estimate lower bounds on the error rates of Complete Genomics and Illumina HiSeq whole-genome and whole-exome sequencing. Error rates for nonreference genotype calls range from 0.1% to 0.6%, depending on the platform and the depth of coverage. Additionally, we found (1) no difference in the error profiles or rates between blood and saliva samples; (2) Complete Genomics sequences had substantially higher error rates than Illumina sequences had; (3) error rates were higher (up to 6%) for rare or unique variants; (4) error rates generally declined with genotype quality (GQ) score, but in a nonlinear fashion for the Illumina data, likely due to loss of specificity of GQ scores greater than 60; and (5) error rates increased with increasing depth of coverage for the Illumina data. These findings, especially (3)-(5), suggest that caution should be taken in interpreting the results of next-generation sequencing-based association studies, and even more so in clinical application of this technology in the absence of validation by other more robust sequencing or genotyping methods. © 2014 Wall et al.; Published by Cold Spring Harbor Laboratory Press.

  12. Personality, self-rated health, and subjective age in a life-span sample: the moderating role of chronological age.

    PubMed

    Stephan, Yannick; Demulier, Virginie; Terracciano, Antonio

    2012-12-01

    The present study tested whether chronological age moderates the association between subjective age and self-rated health and personality in a community-dwelling life-span sample (N = 1,016; age range: 18-91 years). Self-rated health, extraversion, and openness to experience were associated with a younger subjective age at older ages. Conscientious individuals felt more mature early in life. Conscientiousness, neuroticism, and agreeableness were not related to subjective age at older ages. These findings suggest that with aging self-rated health and personality traits are increasingly important for subjective age. 2013 APA, all rights reserved

  13. Mechanical and Infrared Thermography Analysis of Shape Memory Polyurethane

    NASA Astrophysics Data System (ADS)

    Pieczyska, Elzbieta Alicja; Maj, Michal; Kowalczyk-Gajewska, Katarzyna; Staszczak, Maria; Urbanski, Leszek; Tobushi, Hisaaki; Hayashi, Shunichi; Cristea, Mariana

    2014-07-01

    Multifunctional new material—polyurethane shape memory polymer (PU-SMP)—was subjected to tension carried out at room temperature at various strain rates. The influence of effects of thermomechanical couplings on the SMP mechanical properties was studied, based on the sample temperature changes, measured by a fast and sensitive infrared camera. It was found that the polymer deformation process strongly depends on the strain rate applied. The initial reversible strain is accompanied by a small drop in temperature, called thermoelastic effect. Its maximal value is related to the SMP yield point and increases upon increase of the strain rate. At higher strains, the stress and temperature significantly increase, caused by reorientation of the polymer molecular chains, followed by the stress drop and its subsequent increase accompanying the sample rupture. The higher strain rate, the higher stress, and temperature changes were obtained, since the deformation process was more dynamic and has occurred in almost adiabatic conditions. The constitutive model of SMP valid in finite strain regime was developed. In the proposed approach, SMP is described as a two-phase material composed of hyperelastic rubbery phase and elastic-viscoplastic glassy phase, while the volume content of phases is specified by the current temperature.

  14. The effect of newly induced mutations on the fitness of genotypes and populations of yeast (Saccharomyces cerevisiae).

    PubMed

    Orthen, E; Lange, P; Wöhrmann, K

    1984-12-01

    This paper analyses the fate of artificially induced mutations and their importance to the fitness of populations of the yeast, Saccharomyces cerevisiae, an increasingly important model organism in population genetics. Diploid strains, treated with UV and EMS, were cultured asexually for approximately 540 generations and under conditions where the asexual growth was interrupted by a sexual phase. Growth rates of 100 randomly sampled diploid clones were estimated at the beginning and at the end of the experiment. After the induction of sporulation the growth rates of 100 randomly sampled spores were measured. UV and EMS treatment decreases the average growth rate of the clones significantly but increases the variability in comparison to the untreated control. After selection over approximately 540 generations, variability in growth rates was reduced to that of the untreated control. No increase in mean population fitness was observed. However, the results show that after selection there still exists a large amount of hidden genetic variability in the populations which is revealed when the clones are cultivated in environments other than those in which selection took place. A sexual phase increased the reduction of the induced variability.

  15. Using re-randomization to increase the recruitment rate in clinical trials - an assessment of three clinical areas.

    PubMed

    Kahan, Brennan C

    2016-12-13

    Patient recruitment in clinical trials is often challenging, and as a result, many trials are stopped early due to insufficient recruitment. The re-randomization design allows patients to be re-enrolled and re-randomized for each new treatment episode that they experience. Because it allows multiple enrollments for each patient, this design has been proposed as a way to increase the recruitment rate in clinical trials. However, it is unknown to what extent recruitment could be increased in practice. We modelled the expected recruitment rate for parallel-group and re-randomization trials in different settings based on estimates from real trials and datasets. We considered three clinical areas: in vitro fertilization, severe asthma exacerbations, and acute sickle cell pain crises. We compared the two designs in terms of the expected time to complete recruitment, and the sample size recruited over a fixed recruitment period. Across the different scenarios we considered, we estimated that re-randomization could reduce the expected time to complete recruitment by between 4 and 22 months (relative reductions of 19% and 45%), or increase the sample size recruited over a fixed recruitment period by between 29% and 171%. Re-randomization can increase recruitment most for trials with a short follow-up period, a long trial recruitment duration, and patients with high rates of treatment episodes. Re-randomization has the potential to increase the recruitment rate in certain settings, and could lead to quicker and more efficient trials in these scenarios.

  16. Effects of Bedrock Landsliding on Cosmogenically Determined Erosion Rates

    NASA Technical Reports Server (NTRS)

    Niemi, Nathan; Oskin, Mike; Burbank, Douglas; Heimsath, Arjun

    2005-01-01

    The successful quantification of long-term erosion rates underpins our understanding of landscape. formation, the topographic evolution of mountain ranges, and the mass balance within active orogens. The measurement of in situ-produced cosmogenic radionuclides (CRNs) in fluvial and alluvial sediments is perhaps the method with the greatest ability to provide such long-term erosion rates. In active orogens, however, deep-seated bedrock landsliding is an important erosional process, the effect of which on CRN-derived erosion rates is largely unquantified. We present a numerical simulation of cosmogenic nuclide production and distribution in landslide-dominated catchments to address the effect of bedrock landsliding on cosmogenic erosion rates in actively eroding landscapes. Results of the simulation indicate that the temporal stability of erosion rates determined from CRN concentrations in sediment decreases with increased ratios of landsliding to sediment detachment rates within a given catchment area, and that larger catchment areas must be sampled with increased frequency of landsliding in order to accurately evaluate long-term erosion rates. In addition, results of this simulation suggest that sediment sampling for CRNs is the appropriate method for determining long-term erosion rates in regions dominated by mass-wasting processes, while bedrock surface sampling for CRNs is generally an ineffective means of determining long-term erosion rates. Response times of CRN concentrations to changes in erosion rate indicate that climatically driven cycles of erosion may be detected relatively quickly after such changes occur, but that complete equilibration of CRN concentrations to new erosional conditions may take tens of thousands of years. Simulation results of CRN erosion rates are compared with a new, rich dataset of CRN concentrations from the Nepalese Himalaya, supporting conclusions drawn from the simulation.

  17. Investigation on the Effect of Mold Constraints and Cooling Rate on Residual Stress During the Sand-Casting Process of 1086 Steel by Employing a Thermomechanical Model

    NASA Astrophysics Data System (ADS)

    Baghani, Amir; Davami, Parviz; Varahram, Naser; Shabani, Mohsen Ostad

    2014-06-01

    In this study, the effects of mold constraints and cooling rate on residual stress were analyzed during the shaped casting process. For this purpose, an H-shaped sample was designed in which the contraction of its middle portion is highly restricted by the mold during the cooling process. The effects of an increasing cooling rate combined with mold constraints were analyzed by reducing the thickness of the middle portion in the second sample. A three-dimensional coupled temperature-displacement analysis was performed in finite-element code ABAQUS to simulate residual stress distribution, and then numerical results were verified by the hole-drilling strain-gauge method. It was concluded that the mold constraints have a greater effect on the values of residual stress than the cooling rate (thin section) in steel sand casting. Increasing the cooling rate would increase the amount of residual stress, only in the presence of mold constraints. It is also suggested that employing the elastic-plastic stress model for the sand mold will satisfy the experimental results and avoid exaggerated values of residual stress in simulation.

  18. Detection of Coxiella burnetii DNA and anti-Coxiella burnetii IgG antibodies in precolostral blood samples of stillborn calves in an endemically infected Holstein dairy herd.

    PubMed

    Freick, Markus; Konrath, Andrea; Enbergs, Haimo; Walraph, Jörg; Weber, Jim; Eulenberger, Karin

    2018-03-01

    Coxiella burnetii (C. burnetii), an intracellular zoonotic bacterium causing Q fever, occurs widely in cattle herds. After invasion of the pregnant uterus and initial localization in the placenta, active C. burnetii infections may spread to the fetus hematogenously or by the amniotic-oral route and thus may cause abortion, premature delivery, stillbirth, and weak offspring (APSW) complex. In a case-control study, we investigated precolostral blood samples of 56 stillborn calves and 30 live births from a dairy herd endemically infected with C. burnetii "C-cluster" strains and an increased stillbirth rate in primiparous cows. Within the group of the stillborn calves, four precolostral blood samples (7.1%) were tested positive for C. burnetii DNA by PCR and one serum sample (1.8%) positive for anti-C. burnetii IgG antibodies by a commercial ELISA test, respectively. Neither C. burnetii DNA nor anti-C. burnetii IgG antibodies were detected in the samples of calves being born alive. In conclusion, we demonstrated that coxiellaemia and precolostral seroconversion occurred sporadically in stillborn calves from this endemically infected herd. Due to the low detection rates, C. burnetii could not be confirmed to be the cause of the increased stillbirth rate.

  19. Improved Procedure for Transport of Dental Plaque Samples and Other Clinical Specimens Containing Anaerobic Bacteria

    PubMed Central

    Spiegel, Carol A.; Minah, Glenn E.; Krywolap, George N.

    1979-01-01

    An improved transport system for samples containing anaerobic bacteria was developed. This system increased the recovery rate of anaerobic bacteria up to 28.8% as compared to a commonly used method. PMID:39087

  20. Compton suppression gamma-counting: The effect of count rate

    USGS Publications Warehouse

    Millard, H.T.

    1984-01-01

    Past research has shown that anti-coincidence shielded Ge(Li) spectrometers enhanced the signal-to-background ratios for gamma-photopeaks, which are situated on high Compton backgrounds. Ordinarily, an anti- or non-coincidence spectrum (A) and a coincidence spectrum (C) are collected simultaneously with these systems. To be useful in neutron activation analysis (NAA), the fractions of the photopeak counts routed to the two spectra must be constant from sample to sample to variations must be corrected quantitatively. Most Compton suppression counting has been done at low count rate, but in NAA applications, count rates may be much higher. To operate over the wider dynamic range, the effect of count rate on the ratio of the photopeak counts in the two spectra (A/C) was studied. It was found that as the count rate increases, A/C decreases for gammas not coincident with other gammas from the same decay. For gammas coincident with other gammas, A/C increases to a maximum and then decreases. These results suggest that calibration curves are required to correct photopeak areas so quantitative data can be obtained at higher count rates. ?? 1984.

  1. Experimental investigation on variation of physical properties of coal samples subjected to microwave irradiation

    NASA Astrophysics Data System (ADS)

    Hu, Guozhong; Yang, Nan; Xu, Guang; Xu, Jialin

    2018-03-01

    The gas drainage rate of low-permeability coal seam is generally less than satisfactory. This leads to the gas disaster of coal mine, and largely restricts the extraction of coalbed methane (CBM), and increases the emission of greenhouse gases in the mining area. Consequently, enhancing the gas drainage rate is an urgent challenge. To solve this problem, a new approach of using microwave irradiation (MWR) as a non-contact physical field excitation method to enhance gas drainage has been attempted. In order to evaluate the feasibility of this method, the methane adsorption, diffusion and penetrability of coal subjected to MWR were experimentally investigated. The variation of methane adsorbed amount, methane diffusion speed and absorption loop for the coal sample before and after MWR were obtained. The findings show that the MWR can change the adsorption property and reduce the methane adsorption capacity of coal. Moreover, the methane diffusion characteristic curves for both the irradiated coal samples and theoriginal coal samples present the same trend. The irradiated coal samples have better methane diffusion ability than the original ones. As the adsorbed methane decreases, the methane diffusion speed increases or remain the same for the sample subjected to MWR. Furthermore, compared to the original coal samples, the area of the absorption loop for irradiated samples increases, especially for the micro-pore and medium-pore stage. This leads to the increase of open pores in the coal, thus improving the gas penetrability of coal. This study provides supports for positive MWR effects on changing the methane adsorption and improving the methane diffusion and the gas penetrability properties of coal samples.

  2. [Comparison between old and new methods for detection of allergenic substances (egg and milk)].

    PubMed

    Watanabe, Hiroko; Akaboshi, Chie; Saita, Kiyotaka; Sekido, Haruko; Hashiguchi, Shigeki; Watabe, Kenjiro; Tanaka, Kouki

    2011-01-01

    The old ELISA method for detection of allergenic substances (egg and milk) in Kanagawa prefecture from 2003 to 2007, employed before improvement of the food allergen labeling system, yielded detection rates of 20% for egg and 30% for milk. In 2005, after improvement of the labeling system, the detection rate using the new ELISA in solutions containing 1% SDS and 7% 2-mercaptoethanol increased by about 10% for egg, but decreased by half for milk. There were 4 positive samples (over 10 µg/g) for both egg and milk proteins, on account of contamination by ingredients at the manufacturing line and the lack of proper food labeling. In 2009, the contamination levels of egg and milk proteins in labeled commercial foods were low. In a comparison between the new and old methods with the same samples, both the new ELISA and Western-blot analyses showed an increase in the detection rate of egg protein. In relation to milk protein, the detection rates were decreased with the new ELISA, although the ELISA detection rate and consistency rates with Western-blot analysis were increased. On the other hand, in the case of a protein content below 5 µg/g, it was impossible to determine ovomucoid and casein by Western-blot analysis.

  3. Strength of Wet and Dry Montmorillonite

    NASA Astrophysics Data System (ADS)

    Morrow, C. A.; Lockner, D. A.; Moore, D. E.

    2015-12-01

    Montmorillonite, an expandable smectite clay, is a common mineral in fault zones to a depth of around 3 km. Its low strength relative to other common fault gouge minerals is important in many models of fault rheology. However, the coefficient of friction is not well constrained in the literature due to the difficulty of establishing fully drained or fully dried states in the laboratory. For instance, in some reported studies, samples were either partially saturated or possibly over pressured, leading to wide variability in reported shear strength. In this study, the coefficient of friction, μ, of both saturated and oven-dried (at 150°C) Na-montmorillonite was measured at normal stresses up to 680 MPa at room temperature and shortening rates from 1.0 to 0.01 μm/s. Care was taken to shear saturated samples slowly enough to avoid pore fluid overpressure in the clay layers. Coefficients of friction are reported after 8 mm of axial displacement in a triaxial apparatus on saw-cut samples containing a layer of montmorillonite gouge, with either granite or sandstone driving blocks. For saturated samples, μ increased from around 0.1 at low pressure to 0.25 at the highest test pressures. In contrast, values for oven-dried samples decreased asymptotically from approximately 0.78 at 10 MPa normal stress to around 0.45 at 400-680 MPa. While wet and dry strengths approached each other with increasing effective normal stress, wet strength remained only about half of the dry strength at 600 MPa effective normal stress. The increased coefficient of friction can be correlated with a reduction in the number of loosely bound lubricating surface water layers on the clay platelets due to applied normal stress under saturated conditions. The steady-state rate dependence of friction, a-b, was positive and dependent on normal stress. For saturated samples, a-b increased linearly with applied normal stress from ~0 to 0.004, while for dry samples a-b decreased with increasing normal stress from 0.008 to 0.002. All values were either neutral or rate strengthening, indicating a tendency for stable sliding.

  4. Study of Creep of Alumina-Forming Austenitic Stainless Steel for High-Temperature Energy Applications

    NASA Astrophysics Data System (ADS)

    Afonina, Natalie Petrovna

    To withstand the high temperature (>700°C) and pressure demands of steam turbines and boilers used for energy applications, metal alloys must be economically viable and have the necessary material properties, such as high-temperature creep strength, oxidation and corrosion resistance, to withstand such conditions. One promising class of alloys potentially capable of withstanding the rigors of aggressive environments, are alumina-forming austenitic stainless steels (AFAs) alloyed with aluminum to improve corrosion and oxidation resistance. The effect of aging on the microstructure, high temperature constant-stress creep behavior and mechanical properties of the AFA-type alloy Fe-20Cr-30Ni-2Nb-5Al (at.%) were investigated in this study. The alloy's microstructural evolution with increased aging time was observed prior to creep testing. As aging time increased, the alloy exhibited increasing quantities of fine Fe2Nb Laves phase dispersions, with a precipitate-free zone appearing in samples with higher aging times. The presence of the L1 2 phase gamma'-Ni3Al precipitate was detected in the alloy's matrix at 760°C. A constant-stress creep rig was designed, built and its operation validated. Constant-stress creep tests were performed at 760°C and 35MPa, and the effects of different aging conditions on creep rate were investigated. Specimens aged for 240 h exhibited the highest creep rate by a factor of 5, with the homogenized sample having the second highest rate. Samples aged for 2.4 h and 24 h exhibited similar low secondary creep rates. Creep tests conducted at 700oC exhibited a significantly lower creep rate compared to those at 760oC. Microstructural analysis was performed on crept samples to explore high temperature straining properties. The quantity and size of Fe2Nb Laves phase and NiAl particles increased in the matrix and on grain boundaries with longer aging time. High temperature tensile tests were performed and compared to room temperature results. The high temperature results were significantly lower when compared to room temperature values. Higher creep rates were correlated with lower yield strengths.

  5. Sample substitution can be an acceptable data-collection strategy: the case of the Belgian Health Interview Survey.

    PubMed

    Demarest, Stefaan; Molenberghs, Geert; Van der Heyden, Johan; Gisle, Lydia; Van Oyen, Herman; de Waleffe, Sandrine; Van Hal, Guido

    2017-11-01

    Substitution of non-participating households is used in the Belgian Health Interview Survey (BHIS) as a method to obtain the predefined net sample size. Yet, possible effects of applying substitution on response rates and health estimates remain uncertain. In this article, the process of substitution with its impact on response rates and health estimates is assessed. The response rates (RR)-both at household and individual level-according to the sampling criteria were calculated for each stage of the substitution process, together with the individual accrual rate (AR). Unweighted and weighted health estimates were calculated before and after applying substitution. Of the 10,468 members of 4878 initial households, 5904 members (RRind: 56.4%) of 2707 households (RRhh: 55.5%) participated. For the three successive (matched) substitutes, the RR dropped to 45%. The composition of the net sample resembles the one of the initial samples. Applying substitution did not produce any important distorting effects on the estimates. Applying substitution leads to an increase in non-participation, but does not impact the estimations.

  6. Intimate partner violence trends in Brazil: data from two waves of the Brazilian National Alcohol and Drugs Survey.

    PubMed

    Ally, Elizabeth Z; Laranjeira, Ronaldo; Viana, Maria C; Pinsky, Ilana; Caetano, Raul; Mitsuhiro, Sandro; Madruga, Clarice S

    2016-01-01

    To compare intimate partner violence (IPV) prevalence rates in 2006 and 2012 in a nationally representative household sample in Brazil. The associations between IPV and substance use were also investigated. IPV was assessed using the Conflict Tactic Scale-R in two waves (2006/2012) of the Brazilian Alcohol and Drugs Survey. Weighted prevalence rates and adjusted logistic regression models were calculated. Prevalence rates of IPV victimization decreased significantly, especially among women (8.8 to 6.3%). The rates of IPV perpetration also decreased significantly (10.6 to 8.4% for the overall sample and 9.2 to 6.1% in men), as well as the rates of bidirectional violence (by individuals who were simultaneously victims and perpetrators of violence) (3.2 to 2.4% for the overall sample). Alcohol increased the likelihood of being a victim (odds ratio [OR] = 1.6) and perpetrator (OR = 2.4) of IPV. Use of illicit drugs increased up to 4.5 times the likelihood of being a perpetrator. In spite of the significant reduction in most types of IPV between 2006 and 2012, violence perpetrated by women was not significantly reduced, and the current national rates are still high. Further, this study suggests that use of alcohol and other psychoactive drugs plays a major role in IPV. Prevention initiatives must take drug misuse into consideration.

  7. Dose rate effects in radiation degradation of polymer-based cable materials

    NASA Astrophysics Data System (ADS)

    Plaček, V.; Bartoníček, B.; Hnát, V.; Otáhal, B.

    2003-08-01

    Cable ageing under the nuclear power plant (NPP) conditions must be effectively managed to ensure that the required plant safety and reliability are maintained throughout the plant service life. Ionizing radiation is one of the main stressors causing age-related degradation of polymer-based cable materials in air. For a given absorbed dose, radiation-induced damage to a polymer in air environment usually depends on the dose rate of the exposure. In this work, the effect of dose rate on the degradation rate has been studied. Three types of NPP cables (with jacket/insulation combinations PVC/PVC, PVC/PE, XPE/XPE) were irradiated at room temperature using 60Co gamma ray source at average dose rates of 7, 30 and 100 Gy/h with the doses up to 590 kGy. The irradiated samples have been tested for their mechanical properties, thermo-oxidative stability (using differential scanning calorimetry, DSC), and density. In the case of PVC and PE samples, the tested properties have shown evident dose rate effects, while the XPE material has shown no noticeable ones. The values of elongation at break and the thermo-oxidative stability decrease with the advanced degradation, density tends to increase with the absorbed dose. For XPE samples this effect can be partially explained by the increase of crystallinity. It was tested by the DSC determination of the crystalline phase amount.

  8. Evaluation and optimization of sampling errors for the Monte Carlo Independent Column Approximation

    NASA Astrophysics Data System (ADS)

    Räisänen, Petri; Barker, W. Howard

    2004-07-01

    The Monte Carlo Independent Column Approximation (McICA) method for computing domain-average broadband radiative fluxes is unbiased with respect to the full ICA, but its flux estimates contain conditional random noise. McICA's sampling errors are evaluated here using a global climate model (GCM) dataset and a correlated-k distribution (CKD) radiation scheme. Two approaches to reduce McICA's sampling variance are discussed. The first is to simply restrict all of McICA's samples to cloudy regions. This avoids wasting precious few samples on essentially homogeneous clear skies. Clear-sky fluxes need to be computed separately for this approach, but this is usually done in GCMs for diagnostic purposes anyway. Second, accuracy can be improved by repeated sampling, and averaging those CKD terms with large cloud radiative effects. Although this naturally increases computational costs over the standard CKD model, random errors for fluxes and heating rates are reduced by typically 50% to 60%, for the present radiation code, when the total number of samples is increased by 50%. When both variance reduction techniques are applied simultaneously, globally averaged flux and heating rate random errors are reduced by a factor of #3.

  9. Fishing in the Water: Effect of Sampled Water Volume on Environmental DNA-Based Detection of Macroinvertebrates.

    PubMed

    Mächler, Elvira; Deiner, Kristy; Spahn, Fabienne; Altermatt, Florian

    2016-01-05

    Accurate detection of organisms is crucial for the effective management of threatened and invasive species because false detections directly affect the implementation of management actions. The use of environmental DNA (eDNA) as a species detection tool is in a rapid development stage; however, concerns about accurate detections using eDNA have been raised. We evaluated the effect of sampled water volume (0.25 to 2 L) on the detection rate for three macroinvertebrate species. Additionally, we tested (depending on the sampled water volume) what amount of total extracted DNA should be screened to reduce uncertainty in detections. We found that all three species were detected in all volumes of water. Surprisingly, however, only one species had a positive relationship between an increased sample volume and an increase in the detection rate. We conclude that the optimal sample volume might depend on the species-habitat combination and should be tested for the system where management actions are warranted. Nevertheless, we minimally recommend sampling water volumes of 1 L and screening at least 14 μL of extracted eDNA for each sample to reduce uncertainty in detections when studying macroinvertebrates in rivers and using our molecular workflow.

  10. Estimating pesticide sampling rates by the polar organic chemical integrative sampler (POCIS) in the presence of natural organic matter and varying hydrodynamic conditions.

    PubMed

    Charlestra, Lucner; Amirbahman, Aria; Courtemanch, David L; Alvarez, David A; Patterson, Howard

    2012-10-01

    The polar organic chemical integrative sampler (POCIS) was calibrated to monitor pesticides in water under controlled laboratory conditions. The effect of natural organic matter (NOM) on the sampling rates (R(s)) was evaluated in microcosms containing <0.1-5 mg L(-1) of total organic carbon (TOC). The effect of hydrodynamics was studied by comparing R(s) values measured in stirred (SBE) and quiescent (QBE) batch experiments and a flow-through system (FTS). The level of NOM in the water used in these experiments had no effect on the magnitude of the pesticide sampling rates (p > 0.05). However, flow velocity and turbulence significantly increased the sampling rates of the pesticides in the FTS and SBE compared to the QBE (p < 0.001). The calibration data generated can be used to derive pesticide concentrations in water from POCIS deployed in stagnant and turbulent environmental systems without correction for NOM. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. [Private umbilical cord blood banking does not reduce the number of samples for scientific stem cell research].

    PubMed

    Jacobs, V R; Niemeyer, M; Gottschalk, N; Schneider, K T; Kiechle, M

    2005-12-01

    Private umbilical cord blood (UCB) banking after delivery has increased over the last decade. For adult/somatic stem cell research UCB is an essential source of stem cells and researchers question if the number of UCB samples for research might be reduced by private banking. A survey among seven private blood banks in Germany and analysis and comparison of the number of UCB samples donated for research within the STEMMAT project with private blood banking were performed from 03/2003 to 06/2005 at the Frauenklinik (OB/GYN), Technical University Munich, Germany. Within 27.5 months 1,551 UCB samples were collected for research purposes; the effective recruitment rate was higher than expectations at an effective 66.2 %. Private UCB banking [n = 24] was distributed among three cord blood banks [n = 16, 6 and 4]. The rate of private blood banking was 0.99 % for all deliveries, thus reducing the effective rate for research purpose by only 1.5 %. Under the assumption of active and successful recruitment of scientific UCB samples, private blood banking does not significantly reduce this rate and therefore is a negligible rival in the competition for sufficient numbers of UCB samples for research.

  12. Analysis of private health insurance premium growth rates: 1985-1992.

    PubMed

    Feldstein, P J; Wickizer, T M

    1995-10-01

    The rate of increase in health care expenditures has been a central policy concern for well over a decade, yet little empirical research has been conducted to examine expenditure growth rates. This study analyzed health insurance premium growth rates for a selected sample of 95 insured groups over the period 1985 to 1992. During this time, premiums increased by approximately 150% in nominal terms and by 45% in real terms. The observed rate of growth was not constant over time, however. The most rapid growth occurred during the years 1986 to 1989; thereafter, the rate of increase in premiums declined. Multivariate analysis was conducted to assess the effects on premium growth rates of selected variables representing insurance benefit design features, market competitive factors, insurance system factors, and group-specific factors. In addition to the percentage increase in benefit payments, other factors found to affect premium growth rates were health maintenance organization market penetration, deductible level, the coinsurance rate, and state insurance mandates. Further, this analysis suggests that the insurance underwriting cycle may play an important role in influencing insurance premium growth rates. These results support the belief that health maintenance organization induced competition has potential to control the rate of increase in health care costs.

  13. Random bit generation at tunable rates using a chaotic semiconductor laser under distributed feedback.

    PubMed

    Li, Xiao-Zhou; Li, Song-Sui; Zhuang, Jun-Ping; Chan, Sze-Chun

    2015-09-01

    A semiconductor laser with distributed feedback from a fiber Bragg grating (FBG) is investigated for random bit generation (RBG). The feedback perturbs the laser to emit chaotically with the intensity being sampled periodically. The samples are then converted into random bits by a simple postprocessing of self-differencing and selecting bits. Unlike a conventional mirror that provides localized feedback, the FBG provides distributed feedback which effectively suppresses the information of the round-trip feedback delay time. Randomness is ensured even when the sampling period is commensurate with the feedback delay between the laser and the grating. Consequently, in RBG, the FBG feedback enables continuous tuning of the output bit rate, reduces the minimum sampling period, and increases the number of bits selected per sample. RBG is experimentally investigated at a sampling period continuously tunable from over 16 ns down to 50 ps, while the feedback delay is fixed at 7.7 ns. By selecting 5 least-significant bits per sample, output bit rates from 0.3 to 100 Gbps are achieved with randomness examined by the National Institute of Standards and Technology test suite.

  14. The cooling rate dependence of cation distributions in CoFe2O4

    NASA Technical Reports Server (NTRS)

    De Guire, Mark R.; O'Handley, Robert C.; Kalonji, Gretchen

    1989-01-01

    The room-temperature cation distributions in bulk CoFe2O4 samples, cooled at rates between less than 0.01 and about 1000 C/sec, have been determined using Mossbauer spectroscopy in an 80-kOe magnetic field. With increasing cooling rate, the quenched structure departs increasingly from the mostly ordered cation distribution ordinarily observed at room temperature. However, the cation disorder appears to saturate just short of a random distribution at very high cooling rates. These results are interpreted in terms of a simple relaxation model of cation redistribution kinetics. The disordered cation distributions should lead to increased magnetization and decreased coercivity in CoFe2O4.

  15. Calibration of polyurethane foam (PUF) disk passive air samplers for quantitative measurement of polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs): factors influencing sampling rates.

    PubMed

    Hazrati, Sadegh; Harrad, Stuart

    2007-03-01

    PUF disk passive air samplers are increasingly employed for monitoring of POPs in ambient air. In order to utilize them as quantitative sampling devices, a calibration experiment was conducted. Time integrated indoor air concentrations of PCBs and PBDEs were obtained from a low volume air sampler operated over a 50 d period alongside the PUF disk samplers in the same office microenvironment. Passive sampling rates for the fully-sheltered sampler design employed in our research were determined for the 51 PCB and 7 PBDE congeners detected in all calibration samples. These values varied from 0.57 to 1.55 m3 d(-1) for individual PCBs and from 1.1 to 1.9 m3 d(-1) for PBDEs. These values are appreciably lower than those reported elsewhere for different PUF disk sampler designs (e.g. partially sheltered) employed under different conditions (e.g. in outdoor air), and derived using different calibration experiment configurations. This suggests that sampling rates derived for a specific sampler configuration deployed under specific environmental conditions, should not be extrapolated to different sampler configurations. Furthermore, our observation of variable congener-specific sampling rates (consistent with other studies), implies that more research is required in order to understand fully the factors that influence sampling rates. Analysis of wipe samples taken from the inside of the sampler housing, revealed evidence that the housing surface scavenges particle bound PBDEs.

  16. Effects of normalization on quantitative traits in association test

    PubMed Central

    2009-01-01

    Background Quantitative trait loci analysis assumes that the trait is normally distributed. In reality, this is often not observed and one strategy is to transform the trait. However, it is not clear how much normality is required and which transformation works best in association studies. Results We performed simulations on four types of common quantitative traits to evaluate the effects of normalization using the logarithm, Box-Cox, and rank-based transformations. The impact of sample size and genetic effects on normalization is also investigated. Our results show that rank-based transformation gives generally the best and consistent performance in identifying the causal polymorphism and ranking it highly in association tests, with a slight increase in false positive rate. Conclusion For small sample size or genetic effects, the improvement in sensitivity for rank transformation outweighs the slight increase in false positive rate. However, for large sample size and genetic effects, normalization may not be necessary since the increase in sensitivity is relatively modest. PMID:20003414

  17. In situ studies of velocity in fractured crystalline rocks.

    USGS Publications Warehouse

    Moos, D.; Zoback, M.D.

    1983-01-01

    A study of the effects of macroscopic fractures on P and S wave velocities has been conducted in four wells drilled in granitic rock to depths between 0.6 and 1.2km. The effect of macroscopic fractures is to decrease both Vp and Vs and increase Vp/Vs. In wells with a relatively low density of macroscopic fractures, the in situ velocity is similar to that of saturated core samples under confining pressure in the laboratory, and there is a clear correlation between zones with macroscopic fractures and anomalously low velocities. In wells with numerous macroscopic fractures, the in situ velocity is lower than that of intact samples under pressure, and there is a correlation between the rate at which in situ velocity increases with depth and the rate at which the velocity of laboratory samples increases with pressure. Differences in in situ P wave velocity between wells cannot be explained solely by differences in the degree of macroscopic fracturing, thus emphasizing the importance of composition and microcracks on velocity.-from Authors

  18. Two dimensional eye tracking: Sampling rate of forcing function

    NASA Technical Reports Server (NTRS)

    Hornseth, J. P.; Monk, D. L.; Porterfield, J. L.; Mcmurry, R. L.

    1978-01-01

    A study was conducted to determine the minimum update rate of a forcing function display required for the operator to approximate the tracking performance obtained on a continuous display. In this study, frequency analysis was used to determine whether there was an associated change in the transfer function characteristics of the operator. It was expected that as the forcing function display update rate was reduced, from 120 to 15 samples per second, the operator's response to the high frequency components of the forcing function would show a decrease in gain, an increase in phase lag, and a decrease in coherence.

  19. Effect of increasing the sampling interval to 2 seconds on the radiation dose and accuracy of CT perfusion of the head and neck.

    PubMed

    Tawfik, Ahmed M; Razek, Ahmed A; Elhawary, Galal; Batouty, Nihal M

    2014-01-01

    To evaluate the effect of increasing the sampling interval from 1 second (1 image per second) to 2 seconds (1 image every 2 seconds) on computed tomographic (CT) perfusion (CTP) of head and neck tumors. Twenty patients underwent CTP studies of head and neck tumors with images acquired in cine mode for 50 seconds using sampling interval of 1 second. Using deconvolution-based software, analysis of CTP was done with sampling interval of 1 second and then 2 seconds. Perfusion maps representing blood flow, blood volume, mean transit time, and permeability surface area product (PS) were obtained. Quantitative tumor CTP values were compared between the 2 sampling intervals. Two blinded radiologists compared the subjective quality of CTP maps using a 3-point scale between the 2 sampling intervals. Radiation dose parameters were recorded for the 2 sampling interval rates. No significant differences were observed between the means of the 4 perfusion parameters generated using both sampling intervals; all P >0.05. The 95% limits of agreement between the 2 sampling intervals were -65.9 to 48.1) mL/min per 100 g for blood flow, -3.6 to 3.1 mL/100 g for blood volume, -2.9 to 3.8 seconds for mean transit time, and -10.0 to 12.5 mL/min per 100 g for PS. There was no significant difference between the subjective quality scores of CTP maps obtained using the 2 sampling intervals; all P > 0.05. Radiation dose was halved when sampling interval increased from 1 to 2 seconds. Increasing the sampling interval rate to 1 image every 2 seconds does not compromise the image quality and has no significant effect on quantitative perfusion parameters of head and neck tumors. The radiation dose is halved.

  20. Role of effluent organic matter in the photochemical degradation of compounds of wastewater origin.

    PubMed

    Bodhipaksha, Laleen C; Sharpless, Charles M; Chin, Yu-Ping; MacKay, Allison A

    2017-03-01

    The photoreactivity of treated wastewater effluent organic matter differs from that of natural organic matter, and the indirect phototransformation rates of micropollutants originating in wastewater are expected to depend on the fractional contribution of wastewater to total stream flow. Photodegradation rates of four common compounds of wastewater origin (sulfamethoxazole, sulfadimethoxine, cimetidine and caffeine) were measured in river water, treated municipal wastewater effluent and mixtures of both to simulate various effluent-stream water mixing conditions that could occur in environmental systems. Compounds were chosen for their unique photodegradation pathways with the photochemically produced reactive intermediates, triplet-state excited organic matter ( 3 OM*), singlet oxygen ( 1 O 2 ), and hydroxyl radicals (OH). For all compounds, higher rates of photodegradation were observed in effluent relative to upstream river water. Sulfamethoxazole degraded primarily via direct photolysis, with some contribution from OH and possibly from carbonate radicals and other unidentified reactive intermediates in effluent-containing samples. Sulfadimethoxine also degraded mainly by direct photolysis, and natural organic matter appeared to inhibit this process to a greater extent than predicted by light screening. In the presence of effluent organic matter, sulfadimethoxine showed additional reactions with OH and 1 O 2 . In all water samples, cimetidine degraded by reaction with 1 O 2 (>95%) and caffeine by reaction with OH (>95%). In river water mixtures, photodegradation rate constants for all compounds increased with increasing fractions of effluent. A conservative mixing model was able to predict reaction rate constants in the case of hydroxyl radical reactions, but it overestimated rate constants in the case of 3 OM* and 1 O 2 pathways. Finally, compound degradation rate constants normalized to the rate of light absorption by water correlated with E 2 /E 3 ratios (sample absorbance at 254 nm divided by sample absorbance at 365 nm), suggesting that organic matter optical properties may hold promise to predict indirect compound photodegradation rates for various effluent mixing ratios. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Transitional grain-size-sensitive flow of milky quartz aggregates

    NASA Astrophysics Data System (ADS)

    Fukuda, J. I.; Holyoke, C. W., III; Kronenberg, A. K.

    2014-12-01

    Fine-grained (~15 μm) milky quartz aggregates exhibit reversible flow strengths in triaxial compression experiments conducted at T = 800-900oC, Pc = 1.5 GPa when strain rates are sequentially decreased (typically from 10-3.5 to 10-4.5 and 10-5.5 s-1), and then returned to the original rate (10-3.5 s-1), while samples that experience grain growth at 1000oC (to 35 μm) over the same sequence of strain rates exhibit an irreversible increase in strength. Polycrystalline quartz aggregates have been synthesized from natural milky quartz powders (ground to 5 μm) by HIP methods at T = 1000oC, Pc = 1.5 GPa and t = 24 hours, resulting in dense, fine-grained aggregates of uniform water content of ~4000 ppm (H/106Si), as indicated by a broad OH absorption band at 3400 cm-1. In experiments performed at 800o and 900oC, grain sizes of the samples are essentially constant over the duration of each experiment, though grain shapes change significantly, and undulatory extinction and deformation lamellae indicate that much of the sample shortening (to 50%) is accomplished, over the four strain-rate steps, by dislocation creep. Differential stresses measured at T = 800oC decrease from 160 to 30 MPa as strain rate is reduced from 10-4.6 to 10-5.5 s-1, and a stress of 140 MPa is measured when strain rate is returned to 10-4.5 s-1. Samples deformed at 1000o and 1100oC experience normal grain growth, with grain boundary energy-driven grain-coarsening textures superposed by undulatory extinction and deformation lamellae. Differential stresses measured at 1000oC and strain rates of 10-3.6, 10-4.6, and 10-5.5 s-1 are 185, 80, and 80 MPa, respectively, while an increased flow stress of 260 MPa is measured (following ~28 hours of prior high temperature deformation and grain growth) when strain rate is returned to 10-3.6 s-1. While all samples exhibit lattice preferred orientations, the stress exponent n inferred for the fine-grained 800oC sample is 1.5 and the stress exponent of the coarse-grained 1000oC sample is between ~3 and 4. Our value for n of fine-grained quartz samples (and previously reported values of n < 3 for quartz aggregates with added water) may attest to a component of diffusion creep and grain boundary sliding that accompanies dislocation creep.

  2. Effects of strain rate and surface cracks on the mechanical behaviour of Balmoral Red granite.

    PubMed

    Mardoukhi, Ahmad; Mardoukhi, Yousof; Hokka, Mikko; Kuokkala, Veli-Tapani

    2017-01-28

    This work presents a systematic study on the effects of strain rate and surface cracks on the mechanical properties and behaviour of Balmoral Red granite. The tensile behaviour of the rock was studied at low and high strain rates using Brazilian disc samples. Heat shocks were used to produce samples with different amounts of surface cracks. The surface crack patterns were analysed using optical microscopy, and the complexity of the patterns was quantified by calculating the fractal dimensions of the patterns. The strength of the rock clearly drops as a function of increasing fractal dimensions in the studied strain rate range. However, the dynamic strength of the rock drops significantly faster than the quasi-static strength, and, because of this, also the strain rate sensitivity of the rock decreases with increasing fractal dimensions. This can be explained by the fracture behaviour and fragmentation during the dynamic loading, which is more strongly affected by the heat shock than the fragmentation at low strain rates.This article is part of the themed issue 'Experimental testing and modelling of brittle materials at high strain rates'. © 2016 The Author(s).

  3. Designing a national soil erosion monitoring network for England and Wales

    NASA Astrophysics Data System (ADS)

    Lark, Murray; Rawlins, Barry; Anderson, Karen; Evans, Martin; Farrow, Luke; Glendell, Miriam; James, Mike; Rickson, Jane; Quine, Timothy; Quinton, John; Brazier, Richard

    2014-05-01

    Although soil erosion is recognised as a significant threat to sustainable land use and may be a priority for action in any forthcoming EU Soil Framework Directive, those responsible for setting national policy with respect to erosion are constrained by a lack of robust, representative, data at large spatial scales. This reflects the process-orientated nature of much soil erosion research. Recognising this limitation, The UK Department for Environment, Food and Rural Affairs (Defra) established a project to pilot a cost-effective framework for monitoring of soil erosion in England and Wales (E&W). The pilot will compare different soil erosion monitoring methods at a site scale and provide statistical information for the final design of the full national monitoring network that will: provide unbiased estimates of the spatial mean of soil erosion rate across E&W (tonnes ha-1 yr-1) for each of three land-use classes - arable and horticultural grassland upland and semi-natural habitats quantify the uncertainty of these estimates with confidence intervals. Probability (design-based) sampling provides most efficient unbiased estimates of spatial means. In this study, a 16 hectare area (a square of 400 x 400 m) positioned at the centre of a 1-km grid cell, selected at random from mapped land use across E&W, provided the sampling support for measurement of erosion rates, with at least 94% of the support area corresponding to the target land use classes. Very small or zero erosion rates likely to be encountered at many sites reduce the sampling efficiency and make it difficult to compare different methods of soil erosion monitoring. Therefore, to increase the proportion of samples with larger erosion rates without biasing our estimates, we increased the inclusion probability density in areas where the erosion rate is likely to be large by using stratified random sampling. First, each sampling domain (land use class in E&W) was divided into strata; e.g. two sub-domains within which, respectively, small or no erosion rates, and moderate or larger erosion rates are expected. Each stratum was then sampled independently and at random. The sample density need not be equal in the two strata, but is known and is accounted for in the estimation of the mean and its standard error. To divide the domains into strata we used information on slope angle, previous interpretation of erosion susceptibility of the soil associations that correspond to the soil map of E&W at 1:250 000 (Soil Survey of England and Wales, 1983), and visual interpretation of evidence of erosion from aerial photography. While each domain could be stratified on the basis of the first two criteria, air photo interpretation across the whole country was not feasible. For this reason we used a two-phase random sampling for stratification (TPRS) design (de Gruijter et al., 2006). First, we formed an initial random sample of 1-km grid cells from the target domain. Second, each cell was then allocated to a stratum on the basis of the three criteria. A subset of the selected cells from each stratum were then selected for field survey at random, with a specified sampling density for each stratum so as to increase the proportion of cells where moderate or larger erosion rates were expected. Once measurements of erosion have been made, an estimate of the spatial mean of the erosion rate over the target domain, its standard error and associated uncertainty can be calculated by an expression which accounts for the estimated proportions of the two strata within the initial random sample. de Gruijter, J.J., Brus, D.J., Biekens, M.F.P. & Knotters, M. 2006. Sampling for Natural Resource Monitoring. Springer, Berlin. Soil Survey of England and Wales. 1983 National Soil Map NATMAP Vector 1:250,000. National Soil Research Institute, Cranfield University.

  4. Characterization of the corrosion resistance of several alloys to dilute biologically active solutions

    NASA Technical Reports Server (NTRS)

    Walsh, Daniel W.

    1990-01-01

    Sulfate reducing bacteria and acid producing bacteria/fungi detected in hygiene waters increased the corrosion rate in aluminum alloy. Biologically active media enhanced the formation of pits on metal coupons. Direct observation of gas evolved at the corrosion sample, coupled with scanning electron microscopy (SEM) and energy dispersive x-ray analysis of the corrosion products indicates that the corrosion rate is increased because the presence of bacteria favor the reduction of hydrogen as the cathodic reaction through the reaction of oxygen and water. SEM verifies the presence of microbes in a biofilm on the surface of corroding samples. The bacterial consortia are associated with anodic sites on the metal surface, aggressive pitting occurs adjacent to biofilms. Many pits are associated with triple points and inclusions in the aluminum alloy microstructure. Similar bacterial colonization was found on the stainless steel samples. Fourier transform Infrared Spectroscopy confirmed the presence of carbonyl groups in pitted areas of samples exposed to biologically active waters.

  5. Effects of {10-12} Twins on Dynamic Torsional Properties of Extruded AZ31 Magnesium Alloy

    NASA Astrophysics Data System (ADS)

    Lee, Jong Un; Song, Seok Weon; Kim, Yongjin; Kim, Sang-Hoon; Kim, Ye Jin; Park, Sung Hyuk

    2018-03-01

    Effects of initial twins on dynamic torsional properties of extruded AZ31 alloy were investigated by introducing {10-12} twins into it through precompression to 3 and 6% strains along the extrusion direction and performing torsional testing at a strain rate of 1.4 × 103 s-1 using a torsional Kolsky bar system. The as-extruded sample without twins showed higher dynamic torsional properties than the precompressed samples with many initial twins; the maximum shear strength and fracture shear strain decreased with increasing amount of initial twins. In the as-extruded sample, twinning occurred vigorously throughout the gage section of the tubular specimen during high-strain-rate torsional tests, resulting in heavily deformed morphology, many macrocracks, and rough fractured surfaces. The increased amount of initial twins suppressed the twinning behavior and localized the applied torsional deformation; this resulted in an almost unchanged sample shape, no secondary cracks, and a flat fracture plane, thereby deteriorating the dynamic torsional properties of the extruded alloy.

  6. Irradiation of nuclear materials with laser-plasma filaments produced in air and deuterium by terrawatt (TW) laser pulses

    NASA Astrophysics Data System (ADS)

    Avotina, Liga; Lungu, Mihail; Dinca, Paul; Butoi, Bogdan; Cojocaru, Gabriel; Ungureanu, Razvan; Marcu, Aurelian; Luculescu, Catalin; Hapenciuc, Claudiu; Ganea, Paul C.; Petjukevics, Aleksandrs; Lungu, Cristian P.; Kizane, Gunta; Ticos, C. M.; Antohe, Stefan

    2018-01-01

    Be-C-W mixed materials with variable atomic ratios were exposed to high power (TW) laser induced filamentation plasma in air in normal conditions and in deuterium at a reduced pressure of 20 Torr. Morphological and structural investigations were performed on the irradiated zones for both ambient conditions. The presence of low-pressure deuterium increased the overall ablation rate for all samples. From the elemental concentration point of view, the increase of the carbon percentage has led to an increase in the ablation rate. An increase of the tungsten percentage had the opposite effect. From structural spectroscopic investigations using XPS, Raman and FT-IR of the irradiated and non-irradiated sample surfaces, we conclude that deuterium-induced enhancement of the ablation process could be explained by preferential amorphous carbon removal, possibly by forming deuterated hydrocarbons which further evaporated, weakening the layer structure.

  7. Effect of Quenching Process on the Microstructure and Hardness of High-Carbon Martensitic Stainless Steel

    NASA Astrophysics Data System (ADS)

    Zhu, Qin-tian; Li, Jing; Shi, Cheng-bin; Yu, Wen-tao

    2015-11-01

    The microstructure and hardness of high-carbon martensitic stainless steel (HMSS) were investigated using thermal expansion analyzer, Thermo-calc, scanning electron microscope, x-ray diffraction, and Ultra-high temperature confocal microscope. The results indicate that the experimental steel should be austenitized in the temperature range of 1025-1075 °C, which can give a maximum hardness of 62 HRc with the microstructure consisting of martensite, retained austenite, and some undissolved carbides. With increasing austenitizing temperature, the amount of retained austenite increases, while the volume fraction of carbides increases first and then decreases. The starting temperature and finish temperature of martensite formation decrease with increasing cooling rates. Air-quenched samples can obtain less retained austenite, more compact microstructure, and higher hardness, compared with that of oil-quenched samples. For HMSS, the martensitic transformation takes place at some isolated areas with a slow nucleation rate.

  8. Analysis of ingredient functionality and formulation optimization of an instant peanut beverage mix.

    PubMed

    Howard, Brandy M; Hung, Yen-Con; McWatters, S Kay

    2010-01-01

    Powder for an instant shake-style beverage was created using partially defatted peanut flour (12% fat), granulated sugar, and nonfat dry milk (NFDM). The 3 main components, along with constant amounts of stabilizing gums and anti-caking silica, were mixed together and finely milled in a Super Wing Mill to further reduce the particle sizes. Drinks from each formula variation were prepared and analyzed for viscosity (digital viscometer), color (colorimeter), and separation rate. Each beverage was also analyzed by consumers to determine acceptability of flavor, mouth-feel, and color. Physical test results show that viscosity increased with increasing proportion of peanut flour in the formula, and viscosity decreased with increasing levels of sugar and NFDM. For each formula, the samples at refrigerated temperature (4 degrees C) were less viscous than those at ambient temperatures (23 to 25 degrees C). Color values show that the beverage powder color was mostly influenced by peanut flour percentage, becoming darker with increasing levels of peanut flour. Prepared beverage color was influenced by both NFDM and peanut flour percentage; lightness increased with increasing NFDM percentage and decreased with increasing peanut flour percentage. Separation rates were most affected by the proportion of NFDM in the formula; higher levels decreased the rate of separation. Refrigeration slowed the rate of separation in all samples. Response surface analysis of consumer test data showed that the most acceptable formulation for the peanut beverage included approximately equal amounts of peanut flour, sugar, and NFDM.

  9. Esterified propoxylated glycerol soyate, a fat substitute model compound, and soy oil after heating.

    PubMed

    Artz, W E; Soheili, K C; Arjona, I M

    1999-09-01

    The changes occurring in two oil samples [EPG-00 soyate (transesterified soybean oil) and soy oil esterified propoxylated glycerol (EPG-08 soyate, a model, fat substitute compound)] were compared after heating at approximately 190 degrees C for 12 h/day. The EPG-00 soyate sample required 48 h of heating to attain a polymer content >20%, while the EPG-08 soyate required only 36 h. After 48 h of heating the EPG-00 soyate sample, the free fatty acid value (FFA) increased from 0.19 to 0.79, the acid value (AV) increased from 0.10 to 1.59, and the p-anisidine value (p-AV) increased from 1.6 to 195.4. In comparison, after only 36 h of heating, the EPG-08 soyate sample had FFA, AV, and p-AV increases from 0.19 to 0.71, from 0.26 to 1.36, and from 1.1 to 191.7, respectively. The triacylglycerol substrate degradation rate for EPG-00 soyate was k = 0.0126 +/- 0.0003 h(-)(1), while the rate for EPG-08 soyate was k = 0.0166 +/- 0.0017 h(-)(1). The results suggest that the EPG-00 soyate or transesterified soybean oil is slightly more stable than EPG-08 soyate.

  10. Effect of coating mild steel with CNTs on its mechanical properties and corrosion behaviour in acidic medium

    NASA Astrophysics Data System (ADS)

    Abdulmalik Abdulrahaman, Mahmud; Kamaldeeen Abubakre, Oladiran; Ambali Abdulkareem, Saka; Oladejo Tijani, Jimoh; Aliyu, Ahmed; Afolabi, Ayo Samuel

    2017-03-01

    The study investigated the mechanical properties and corrosion behaviour of mild steel coated with carbon nanotubes at different coating conditions. Multi-walled carbon nanotubes (MWCNTs) were synthesized via the conventional chemical vapour deposition reaction using bimetallic Fe-Ni catalyst supported on kaolin, with acetylene gas as a carbon source. The HRSEM/HRTEM analysis of the purified carbon materials revealed significant reduction in the diameters of the purified MWCNT bundles from 50 nm to 2 nm and was attributed to the ultrasonication assisted dispersion with surfactant (gum arabic) employed in purification process. The network of the dispersed MWCNTs was coated onto the surfaces of mild steel samples, and as the coating temperature and holding time increased, the coating thickness reduced. The mechanical properties (tensile strength, yield strength, hardness value) of the coated steel samples increased with increase in coating temperature and holding time. Comparing the different coating conditions, coated mild steels at the temperature of 950 °C for 90 min holding time exhibited high hardness, yield strength and tensile strength values compared to others. The corrosion current and corrosion rate of the coated mild steel samples decreased with increase in holding time and coating temperature. The lowest corrosion rate was observed on sample coated at 950 °C for 90 min.

  11. Quantization noise in digital speech. M.S. Thesis- Houston Univ.

    NASA Technical Reports Server (NTRS)

    Schmidt, O. L.

    1972-01-01

    The amount of quantization noise generated in a digital-to-analog converter is dependent on the number of bits or quantization levels used to digitize the analog signal in the analog-to-digital converter. The minimum number of quantization levels and the minimum sample rate were derived for a digital voice channel. A sample rate of 6000 samples per second and lowpass filters with a 3 db cutoff of 2400 Hz are required for 100 percent sentence intelligibility. Consonant sounds are the first speech components to be degraded by quantization noise. A compression amplifier can be used to increase the weighting of the consonant sound amplitudes in the analog-to-digital converter. An expansion network must be installed at the output of the digital-to-analog converter to restore the original weighting of the consonant sounds. This technique results in 100 percent sentence intelligibility for a sample rate of 5000 samples per second, eight quantization levels, and lowpass filters with a 3 db cutoff of 2000 Hz.

  12. A fiber optic sensor for noncontact measurement of shaft speed, torque, and power

    NASA Technical Reports Server (NTRS)

    Madzsar, George C.

    1990-01-01

    A fiber optic sensor which enables noncontact measurement of the speed, torque and power of a rotating shaft was fabricated and tested. The sensor provides a direct measurement of shaft rotational speed and shaft angular twist, from which torque and power can be determined. Angles of twist between 0.005 and 10 degrees were measured. Sensor resolution is limited by the sampling rate of the analog to digital converter, while accuracy is dependent on the spot size of the focused beam on the shaft. Increasing the sampling rate improves measurement resolution, and decreasing the focused spot size increases accuracy. Digital processing allows for enhancement of an electronically or optically degraded signal.

  13. A fiber optic sensor for noncontact measurement of shaft speed, torque and power

    NASA Technical Reports Server (NTRS)

    Madzsar, George C.

    1990-01-01

    A fiber optic sensor which enables noncontact measurement of the speed, torque and power of a rotating shaft was fabricated and tested. The sensor provides a direct measurement of shaft rotational speed and shaft angular twist, from which torque and power can be determined. Angles of twist between 0.005 and 10 degrees were measured. Sensor resolution is limited by the sampling rate of the analog to digital converter, while accuracy is dependent on the spot size of the focused beam on the shaft. Increasing the sampling rate improves measurement resolution, and decreasing the focused spot size increases accuracy. Digital processing allows for enhancement of an electronically or optically degraded signal.

  14. Lithography hotspot discovery at 70nm DRAM 300mm fab: process window qualification using design base binning

    NASA Astrophysics Data System (ADS)

    Chen, Daniel; Chen, Damian; Yen, Ray; Cheng, Mingjen; Lan, Andy; Ghaskadvi, Rajesh

    2008-11-01

    Identifying hotspots--structures that limit the lithography process window--become increasingly important as the industry relies heavily on RET to print sub-wavelength designs. KLA-Tencor's patented Process Window Qualification (PWQ) methodology has been used for this purpose in various fabs. PWQ methodology has three key advantages (a) PWQ Layout--to obtain the best sensitivity (b) Design Based Binning--for pattern repeater analysis (c) Intelligent sampling--for the best DOI sampling rate. This paper evaluates two different analysis strategies for SEM review sampling successfully deployed at Inotera Memories, Inc. We propose a new approach combining the location repeater and pattern repeaters. Based on a recent case study the new sampling flow reduces the data analysis and sampling time from 6 hours to 1.5 hour maintaining maximum DOI sample rate.

  15. Hydraulic Resistance of Vitreous Cutters: The Impact of Blade Design and Cut Rate.

    PubMed

    Rossi, Tommaso; Querzoli, Giorgio; Angelini, Giampiero; Malvasi, Carlo; Rossi, Alessandro; Morini, Mario; Esposito, Graziana; Micera, Alessandra; di Luca, Natale Mario; Ripandelli, Guido

    2016-07-01

    To measure the hydraulic resistance (HR) of vitreous cutters equipped with a Regular guillotine Blade (RB) or double edge blade (DEB) at cut rates comprised between 0 and 12,000 cuts per minute (CPM) and compare it with vitreous fragment size. This was an in vitro experimental study; in vivo HR measure and vitreous sampling. HR, defined as aspiration pressure/flow rate, was measured in balanced salt solution (BSS; Alcon, Fort Worth, TX) (in vitro) and during pars plana vitrectomy of 20 consecutive patients aged 18 to 65, undergoing macular surgery. HR was recorded at increasing cut rates (500-6000 CPM for the RB and 500-12,000 CPM for the DEB; 5 mL/min flow). Vitreous samples were withdrawn and analyzed with Western and collagen type II and IX immunostaining to evaluate protein size. The main outcome measures were hydraulic resistance (mm Hg/ml/min [±SD]) and optic density for Western blot and immunostaining. RB and DEB showed identical HR in BSS between 0 and 3000 CPM. Above 3000 CPM, RB HR steadily increased, and was significantly higher than DEB HR. Vitreous HR was also similar for the two blades between 0 and 1500 CPM. Above 1500 CPM, RB offered a significantly higher resistance. Western blot and immunostaining of vitreous samples did not yield a significant difference in size, regardless of blade type and cut rate. DEB is more efficient, offering a lower HR than RB over 1500 CPM in human vitreous. There is no viscosity reduction as a function of cut-rate between 1500 and 12,000 CPM, as HR does not vary. Future vitreous cutters will benefit of a DEB; optimal cut rate needs to be defined, and the simple increase of cut rate does not provide benefits after a certain limit to be assessed.

  16. Sample Design, Sample Augmentation, and Estimation for Wave 2 of the NSHAP

    PubMed Central

    English, Ned; Pedlow, Steven; Kwok, Peter K.

    2014-01-01

    Objectives. The sample for the second wave (2010) of National Social Life, Health, and Aging Project (NSHAP) was designed to increase the scientific value of the Wave 1 (2005) data set by revisiting sample members 5 years after their initial interviews and augmenting this sample where possible. Method. There were 2 important innovations. First, the scope of the study was expanded by collecting data from coresident spouses or romantic partners. Second, to maximize the representativeness of the Wave 2 data, nonrespondents from Wave 1 were again approached for interview in the Wave 2 sample. Results. The overall unconditional response rate for the Wave 2 panel was 74%; the conditional response rate of Wave 1 respondents was 89%; the conditional response rate of partners was 84%; and the conversion rate for Wave 1 nonrespondents was 26%. Discussion. The inclusion of coresident partners enhanced the study by allowing the examination of how intimate, household relationships are related to health trajectories and by augmenting the size of the NSHAP sample size for this and future waves. The uncommon strategy of returning to Wave 1 nonrespondents reduced potential bias by ensuring that to the extent possible the whole of the original sample forms the basis for the field effort. NSHAP Wave 2 achieved its field objectives of consolidating the panel, recruiting their resident spouses or romantic partners, and converting a significant proportion of Wave 1 nonrespondents. PMID:25360016

  17. Rate of deoxygenation modulates rheologic behavior of sickle red blood cells at a given mean corpuscular hemoglobin concentration.

    PubMed

    Kaul, D K; Liu, X D

    1999-01-01

    Although the mean corpuscular hemoglobin concentration (MCHC) plays a dominant role in the rheologic behavior of deoxygenated density-defined sickle red blood cells (SS RBCs), previous studies have not explored the relationship between the rate of deoxygenation and the bulk viscosity of SS RBCs at a given MCHC. In the present study, we have subjected density-defined SS classes (i.e., medium-density SS4 and dense SS5 discocytes) to varying deoxygenation rates. This approach has allowed us to minimize the effects of SS RBC heterogeneity and investigate the effect of deoxygenation rates at a given MCHC. The results show that the percentages of granular cells, classic sickle cells and holly leaf forms in deoxygenated samples are significantly influenced by the rate of deoxygenation and the MCHC of a given discocyte subpopulation. Increasing the deoxygenation rate using high K+ medium (pH 6.8), results in a greater percentage of granular cells in SS4 suspensions, accompanied by a pronounced increase in the bulk viscosity of these cells compared with gradually deoxygenated samples (mainly classic sickle cells and holly leaf forms). The effect of MCHC becomes apparent when SS5 dense cells are subjected to varying deoxygenation rates. At a given deoxygenation rate, SS5 dense discocytes show a greater increase in the percentage of granular cells than that observed for SS4 RBCs. Also, at a given deoxygenation rate, SS5 suspensions exhibit a higher viscosity than SS4 suspensions with fast deoxygenation resulting in maximal increase in viscosity. Although MCHC is the main determinant of SS RBC rheologic behavior, these studies demonstrate for the first time that at a given MCHC, the rate of deoxygenation (hence HbS polymerization rates) further modulates the rheologic behavior of SS RBCs. Thus, both MCHC and the deoxygenation rate may contribute to microcirculatory flow behavior of SS RBCs.

  18. Intrinsic viscosity and rheological properties of natural and substituted guar gums in seawater.

    PubMed

    Wang, Shibin; He, Le; Guo, Jianchun; Zhao, Jinzhou; Tang, Hongbiao

    2015-05-01

    The intrinsic viscosity and rheological properties of guar gum (GG), hydroxypropyl guar (HPG) and carboxymethyl guar (CMG) in seawater and the effects of shear rate, concentration, temperature and pH on these properties were investigated. An intrinsic viscosity-increasing effect was observed with GG and HPG in seawater (SW) compared to deionized water (DW), whereas the intrinsic viscosity of CMG in seawater was much lower than that in DW due to a screening effect that reduced the repulsion between the polymer chains. Regardless of the functional groups, all sample solutions was well characterized by a modified Cross model that exhibited the transition from Newtonian to pseudoplastic in the low shear rate range at the concentrations of interest to industries, and their viscosity increased with the increase in their concentration but decreased with the increase in temperature. In contrast to nonionic GG or HPG, anionic CMG had a slightly decreased viscosity property in SW, exhibiting polyelectrolyte viscosity behavior. The α value in the zero-shear rate viscosity vs. concentration power-law equation for the samples gave the order of CMG>HPG>GG while the SW solution of CMG had the lowest viscous flow activation energy and exhibited a strong pH-dependent viscosity by a different shear rate. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Disability and treatment of psychiatric and physical disorders in South Africa.

    PubMed

    Suliman, Sharain; Stein, Dan J; Myer, Landon; Williams, David R; Seedat, Soraya

    2010-01-01

    We aimed to compare disability rates associated with physical disorders versus psychiatric disorders and to establish treatment rates of both classes of disorder in the South African population. In a nationally representative survey of 4351 adults, treatment and prevalence rates of a range of physical and psychiatric disorders, and their associated morbidity during the previous 12 months were investigated. Physical illnesses were reported in 55.2% of the sample, 60.4% of whom received treatment for their disorder. Approximately 10% of the samples show a mental illness with 6.1% having received treatment for their disorder. The prevalence of any mental illness reported was higher than that reported individually for asthma, cancer, diabetes, and peptic ulcer. Mental disorders were consistently reported to be more disabling than physical disorders and the degree of disability increased as the number of comorbid disorders increased. Depression, in particular, was rated consistently higher across all domains than all physical disorders. Despite high rates of mental disorders and associated disability in South Africa, they are less likely to be treated than physical disorders.

  20. Enthalpy and high temperature relaxation kinetics of stable vapor-deposited glasses of toluene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhattacharya, Deepanjan; Sadtchenko, Vlad, E-mail: vlad@gwu.edu

    Stable non-crystalline toluene films of micrometer and nanometer thicknesses were grown by vapor deposition at distinct rates and probed by fast scanning calorimetry. Fast scanning calorimetry is shown to be extremely sensitive to the structure of the vapor-deposited phase and was used to characterize simultaneously its kinetic stability and its thermodynamic properties. According to our analysis, transformation of vapor-deposited samples of toluene during heating with rates in excess 10{sup 5} K s{sup −1} follows the zero-order kinetics. The transformation rate correlates strongly with the initial enthalpy of the sample, which increases with the deposition rate according to sub-linear law. Analysismore » of the transformation kinetics of vapor-deposited toluene films of various thicknesses reveal a sudden increase in the transformation rate for films thinner than 250 nm. The change in kinetics seems to correlate with the surface roughness scale of the substrate. The implications of these findings for the formation mechanism and structure of vapor-deposited stable glasses are discussed.« less

  1. Disability and Treatment of Psychiatric and Physical Disorders in South Africa

    PubMed Central

    Suliman, Sharain; Stein, Dan J; Myer, Landon; Williams, David R; Seedat, Soraya

    2011-01-01

    We aimed to compare disability rates associated with physical disorders versus psychiatric disorders and to establish treatment rates of both classes of disorder in the South African population. In a nationally representative survey of 4351 adults, treatment and prevalence rates of a range of physical and psychiatric disorders, and their associated morbidity during the previous 12 months were investigated. Physical illnesses were reported in 55.2% of the sample, 60.4% of whom received treatment for their disorder. Approximately 10% of the sample endorsed a mental illness with 6.1% having received treatment for their disorder. The prevalence of any mental illness reported was higher than that reported individually for asthma, cancer, diabetes and peptic ulcer. Mental disorders were consistently reported to be more disabling than physical disorders and the degree of disability increased as the number of comorbid disorders increased. Depression, in particular, was rated consistently higher across all domains than all physical disorders. Despite high rates of mental disorders and associated disability in South Africa, they are less likely to be treated than physical disorders. PMID:20061863

  2. Sample-Clock Phase-Control Feedback

    NASA Technical Reports Server (NTRS)

    Quirk, Kevin J.; Gin, Jonathan W.; Nguyen, Danh H.; Nguyen, Huy

    2012-01-01

    To demodulate a communication signal, a receiver must recover and synchronize to the symbol timing of a received waveform. In a system that utilizes digital sampling, the fidelity of synchronization is limited by the time between the symbol boundary and closest sample time location. To reduce this error, one typically uses a sample clock in excess of the symbol rate in order to provide multiple samples per symbol, thereby lowering the error limit to a fraction of a symbol time. For systems with a large modulation bandwidth, the required sample clock rate is prohibitive due to current technological barriers and processing complexity. With precise control of the phase of the sample clock, one can sample the received signal at times arbitrarily close to the symbol boundary, thus obviating the need, from a synchronization perspective, for multiple samples per symbol. Sample-clock phase-control feedback was developed for use in the demodulation of an optical communication signal, where multi-GHz modulation bandwidths would require prohibitively large sample clock frequencies for rates in excess of the symbol rate. A custom mixedsignal (RF/digital) offset phase-locked loop circuit was developed to control the phase of the 6.4-GHz clock that samples the photon-counting detector output. The offset phase-locked loop is driven by a feedback mechanism that continuously corrects for variation in the symbol time due to motion between the transmitter and receiver as well as oscillator instability. This innovation will allow significant improvements in receiver throughput; for example, the throughput of a pulse-position modulation (PPM) with 16 slots can increase from 188 Mb/s to 1.5 Gb/s.

  3. 30 CFR 7.47 - Deflection temperature test.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ±3.6 °F (23 ±2 °C) and 50 ±5% relative humidity for at least 40 hours. (2) Place a sample on supports... sample at the point of loading as the temperature of the medium is increased at a uniform rate of 3.6...

  4. 30 CFR 7.47 - Deflection temperature test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ±3.6 °F (23 ±2 °C) and 50 ±5% relative humidity for at least 40 hours. (2) Place a sample on supports... sample at the point of loading as the temperature of the medium is increased at a uniform rate of 3.6...

  5. Massage therapy of moderate and light pressure and vibrator effects on EEG and heart rate.

    PubMed

    Diego, Miguel A; Field, Tiffany; Sanders, Chris; Hernandez-Reif, Maria

    2004-01-01

    Three types of commonly used massage therapy techniques were assessed in a sample of 36 healthy adults, randomly assigned to: (1) moderate massage, (2) light massage, or (3) vibratory stimulation group (n = 12 per group). Changes in anxiety and stress were assessed, and EEG and EKG were recorded. Anxiety scores decreased for all groups, but the moderate pressure massage group reported the greatest decrease in stress. The moderate massage group also experienced a decrease in heart rate and EEG changes including an increase in delta and a decrease in alpha and beta activity, suggesting a relaxation response. Finally, this group showed increased positive affect, as indicated by a shift toward left frontal EEG activation. The light massage group showed increased arousal, as indicated by decreased delta and increased deta activity and increased heart rate. The vibratory stimulation group also showed increased arousal, as indicated by increased heart rate and increased theta, alpha, and beta activity.

  6. Carbon mineralization in acidic, xeric forest soils: induction of new activities.

    PubMed

    Tate, R L

    1985-08-01

    Carbon mineralization was examined in Lakehurst and Atsion sands collected from the New Jersey Pinelands and in Pahokee muck from the Everglades Agricultural Area. Objectives were (i) to estimate the carbon mineralization capacities of acidic, xeric Pinelands soils in the absence of exogenously supplied carbon substrate (nonamended carbon mineralization rate) and to compare these activities with those of agriculturally developed pahokee muck, and (ii) to measure the capacity for increased carbon mineralization in the soils after carbon amendment. In most cases, nonamended carbon mineralization rates were greater in samples of the acid- and moisture-stressed Pinelands soils than in Pahokee muck collected from a fallow (bare) field. Carbon amendment resulted in augmented catabolic activity in Pahokee muck samples, suggesting that the microbial community was carbon limited in this soil. With many of the substrates, no stimulation of the catabolic rate was detected after amendment of Pinelands soils. This was documented by the observation that amendment of Pahokee muck with an amino acid mixture, glucose, or acetate resulted in a 3.0-, 3.9-, or 10.5-fold stimulation of catabolic activity, respectively, for the added substrate. In contrast, amendment of the Pinelands soils resulted in increased amino acid and acetate catabolic rates in Lakehurst sand and increased acetate metabolism only in Atsion sand. Other activities were unchanged. The increased glucose respiration rates resulted from stimulation of existing microbial activity rather than from microbial proliferation since no change in the microbial growth rate, as estimated by the rate of incorporation of C-labeled acetate into cell membranes, occurred after glucose amendment of the soils. A stimulation of microbial growth rate was recorded with glucose-amended Lakehurst sand collected from the B horizon.

  7. Carbon Mineralization in Acidic, Xeric Forest Soils: Induction of New Activities †

    PubMed Central

    Tate, Robert L.

    1985-01-01

    Carbon mineralization was examined in Lakehurst and Atsion sands collected from the New Jersey Pinelands and in Pahokee muck from the Everglades Agricultural Area. Objectives were (i) to estimate the carbon mineralization capacities of acidic, xeric Pinelands soils in the absence of exogenously supplied carbon substrate (nonamended carbon mineralization rate) and to compare these activities with those of agriculturally developed pahokee muck, and (ii) to measure the capacity for increased carbon mineralization in the soils after carbon amendment. In most cases, nonamended carbon mineralization rates were greater in samples of the acid- and moisture-stressed Pinelands soils than in Pahokee muck collected from a fallow (bare) field. Carbon amendment resulted in augmented catabolic activity in Pahokee muck samples, suggesting that the microbial community was carbon limited in this soil. With many of the substrates, no stimulation of the catabolic rate was detected after amendment of Pinelands soils. This was documented by the observation that amendment of Pahokee muck with an amino acid mixture, glucose, or acetate resulted in a 3.0-, 3.9-, or 10.5-fold stimulation of catabolic activity, respectively, for the added substrate. In contrast, amendment of the Pinelands soils resulted in increased amino acid and acetate catabolic rates in Lakehurst sand and increased acetate metabolism only in Atsion sand. Other activities were unchanged. The increased glucose respiration rates resulted from stimulation of existing microbial activity rather than from microbial proliferation since no change in the microbial growth rate, as estimated by the rate of incorporation of 14C-labeled acetate into cell membranes, occurred after glucose amendment of the soils. A stimulation of microbial growth rate was recorded with glucose-amended Lakehurst sand collected from the B horizon. PMID:16346862

  8. Effect of cooling rate and Mg addition on the structural evaluation of rapidly solidified Al-20wt%Cu-12wt%Fe alloy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karaköse, Ercan, E-mail: ekarakose@karatekin.edu.t

    2016-11-15

    The present work examines the effect of Mg contents and cooling rate on the morphology and mechanical properties of Al{sub 20}Cu{sub 12}Fe quasicrystalline alloy. The microstructure of the alloys was analyzed by scanning electron microscopy and the phase composition was identified by X-ray diffractometry. The melting characteristics were studied by differential thermal analysis under an Ar atmosphere. The mechanical features of the melt-spun and conventionally solidified alloys were tested by tensile-strength test and Vickers micro-hardness test. It was found that the final microstructure of the Al{sub 20}Cu{sub 12}Fe samples mainly depends on the cooling rate and Mg contents, which suggestsmore » that different cooling rates and Mg contents produce different microstructures and properties. The average grain sizes of the melt spun samples were about 100–300 nm at 35 m/s. The nanosize, dispersed, different shaped quasicrystal particles possessed a remarkable effect to the mechanical characteristics of the rapidly solidified ribbons. The microhardness values of the melt spun samples were approximately 18% higher than those of the conventionally counterparts. - Highlights: •Quasicrystal-creating materials have high potential for applications. •Different shaped nanosize quasicrystal particles were observed. •The addition of Mg has an important impact on the mechanical properties. •H{sub V} values of the MS0, MS3 and MS5 samples at 35 m/s were 8.56, 8.66 and 8.80 GPa. •The volume fraction of IQC increases with increasing cooling rates.« less

  9. Reduction of hexavalent chromium in water samples acidified for preservation

    USGS Publications Warehouse

    Stollenwerk, K.G.; Grove, D.B.

    1985-01-01

    Reduction of hexavalent chromium, Cr(VI), in water samples, preserved by standard techniques, was investigated. The standard preservation technique for water samples that are to be analyzed for Cr(VI) consists of filtration through a 0.45-??m membrane, acidification to a pH < 2, and storage in plastic bottles. Batch experiments were conducted to evaluate the effect of H+ concentration, NO2, temperature, and dissolved organic carbon (DOC) on the reduction of Cr(VI) to Cr(III). The rate of reduction of Cr(VI) to Cr(III) increased with increasing NO2, DOC, H+, and temperature. Reduction of Cr(VI) by organic matter occurred in some samples even though the samples were unacidified. Reduction of Cr(VI) is inhibited to an extent by storing the sample at 4??C. Stability of Cr(VI) in water is variable and depends on the other constituents present in the sample. Water samples collected for the determination of Cr(VI) should be filtered (0.45-??m membrane), refrigerated, and analyzed as quickly as possible. Water samples should not be acidified. Measurement of total Cr in addition to Cr(VI) can serve as a check for Cr(VI) reduction. If total Cr is greater than Cr(VI), the possibility that Cr(VI) reduction has occurred needs to be considered.The rate of reduction of Cr(VI) to Cr(III) increased with increasing NO//2, DOC, H** plus , and temperature. Reduction of Cr(VI) by organic matter occurred in some samples even though the samples were unacidified. Reduction of Cr(VI) is inhibited to an extent by storing the sample at 4 degree C. Stability of Cr(VI) in water is variable and depends on the other constituents present in the sample. Water samples collected for the determination of Cr(VI) should be filtered (0. 45- mu m membrane), refrigerated, and analyzed as quickly as possible. Water samples should not be acidified. Measurement of total Cr in addition to Cr(VI) can serve as a check for Cr(VI) reduction. If total Cr is greater than Cr(VI), the possibility that Cr(VI) reduction has occurred needs to be considered.

  10. Comparative evaluation of the effects of casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) and xylitol-containing chewing gum on salivary flow rate, pH and buffering capacity in children: An in vivo study.

    PubMed

    Hegde, Rahul J; Thakkar, Janhavi B

    2017-01-01

    This study aimed to compare and evaluate the changes in the salivary flow rate, pH, and buffering capacity before and after chewing casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) and xylitol-containing chewing gums in children. Sixty children aged between 8 and 12 years were selected for the study. They were randomly divided into Group 1 (CPP-ACP chewing gum) and Group 2 (xylitol-containing chewing gum) comprising thirty children each. Unstimulated and stimulated saliva samples at 15 and 30 min interval were collected from all children. All the saliva samples were estimated for salivary flow rate, pH, and buffering capacity. Significant increase in salivary flow rate, pH, and buffering capacity from baseline to immediately after spitting the chewing gum was found in both the study groups. No significant difference was found between the two study groups with respect to salivary flow rate and pH. Intergroup comparison indicated a significant increase in salivary buffer capacity in Group 1 when compared to Group 2. Chewing gums containing CPP-ACP and xylitol can significantly increase the physiochemical properties of saliva. These physiochemical properties of saliva have a definite relation with caries activity in children.

  11. Improving Tracheostomy Care Delivery: Instituting Clinical Care Pathways and Nursing Education to Improve Patient Outcomes.

    PubMed

    Colandrea, Maria; Eckardt, Patricia

    2016-01-01

    The complication rates for tracheostomy patients could be serious and life threatening. As a result, length of stay (LOS) increases and patient outcomes can be negatively impacted. Examples of complications include accidental decannulation, bleeding and total occlusion. Studies suggest there is an inconsistency in tracheostomy care among providers and institutions. Other studies suggest stronger patient outcomes can result from improved staff training and appropriate protocols. The purpose of this study was to develop and test a clinical care pathway (CCP) and nursing education program to improve tracheostomy patient outcomes. The use of a CCP and nursing education program at a tertiary VA Medical Center will: decrease length of stay (LOS). decrease 30 day tracheostomy readmissions. increase patient's readiness for discharge. increase nurses' comfort level with performing tracheostomy care. increase nurses' overall competence with performing tracheostomy care. A quasi-experimental pilot study examining the effect of a CCP compared LOS and complication rates of tracheostomy patients from admission to discharge. The population included veterans from a mid-Atlantic VA Medical Center. This study involved three phases. Phase 1: Administer the Readiness for Hospital Discharge Scale (RHDS) to tracheostomy patients' preintervention. Phase 2: Provide nurses with an educational program pre and post test assessment. Phase 3: Implement the CCP and evaluate patients' readiness for discharge. Comparing the pre-intervention sample of veterans (n = 10) to the post-intervention sample (n = 6), there was an increase in LOS by 1 day. There was a 15 point increase in RHDS from 165 (SD 25.8) to 180 (SD 14.42). This pilot was underpowered with an n = 6, so there was no significant difference in LOS and 30 day readmission rates. Bootstrapping of sample resulted in RHDS p = . 039 and readmission p = .007. A paired-samples t-test was conducted to assess nurses' competence in performing tracheostomy care and nursing comfort level in regards to providing tracheostomy care and discharge education. There was a significant increase in the post-test scores, nursing comfort level providing tracheostomy care and nurses' comfort level providing patient tracheostomy discharge education. The significance of this project improved overall tracheostomy care offered at a mid-Atlantic VA Medical Center. Standardizing tracheostomy care and properly educating nurses and patients, increased patients readiness for hospital discharge and decreased their readmission rates related to tracheostomies.

  12. Adaptive AFM scan speed control for high aspect ratio fast structure tracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmad, Ahmad; Schuh, Andreas; Rangelow, Ivo W.

    2014-10-15

    Improved imaging rates in Atomic Force Microscopes (AFM) are of high interest for disciplines such as life sciences and failure analysis of semiconductor wafers, where the sample topology shows high aspect ratios. Also, fast imaging is necessary to cover a large surface under investigation in reasonable times. Since AFMs are composed of mechanical components, they are associated with comparably low resonance frequencies that undermine the effort to increase the acquisition rates. In particular, high and steep structures are difficult to follow, which causes the cantilever to temporarily loose contact to or crash into the sample. Here, we report on amore » novel approach that does not affect the scanner dynamics, but adapts the lateral scanning speed of the scanner. The controller monitors the control error signal and, only when necessary, decreases the scan speed to allow the z-piezo more time to react to changes in the sample's topography. In this case, the overall imaging rate can be significantly increased, because a general scan speed trade-off decision is not needed and smooth areas are scanned fast. In contrast to methods trying to increase the z-piezo bandwidth, our method is a comparably simple approach that can be easily adapted to standard systems.« less

  13. Angular oversampling with temporally offset layers on multilayer detectors in computed tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sjölin, Martin, E-mail: martin.sjolin@mi.physics.kth.se; Danielsson, Mats

    2016-06-15

    Purpose: Today’s computed tomography (CT) scanners operate at an increasingly high rotation speed in order to reduce motion artifacts and to fulfill the requirements of dynamic acquisition, e.g., perfusion and cardiac imaging, with lower angular sampling rate as a consequence. In this paper, a simple method for obtaining angular oversampling when using multilayer detectors in continuous rotation CT is presented. Methods: By introducing temporal offsets between the measurement periods of the different layers on a multilayer detector, the angular sampling rate can be increased by a factor equal to the number of layers on the detector. The increased angular samplingmore » rate reduces the risk of producing aliasing artifacts in the image. A simulation of a detector with two layers is performed to prove the concept. Results: The simulation study shows that aliasing artifacts from insufficient angular sampling are reduced by the proposed method. Specifically, when imaging a single point blurred by a 2D Gaussian kernel, the method is shown to reduce the strength of the aliasing artifacts by approximately an order of magnitude. Conclusions: The presented oversampling method is easy to implement in today’s multilayer detectors and has the potential to reduce aliasing artifacts in the reconstructed images.« less

  14. Error-eliminating rapid ultrasonic firing

    DOEpatents

    Borenstein, Johann; Koren, Yoram

    1993-08-24

    A system for producing reliable navigation data for a mobile vehicle, such as a robot, combines multiple range samples to increase the "confidence" of the algorithm in the existence of an obstacle. At higher vehicle speed, it is crucial to sample each sensor quickly and repeatedly to gather multiple samples in time to avoid a collision. Erroneous data is rejected by delaying the issuance of an ultrasonic energy pulse by a predetermined wait-period, which may be different during alternate ultrasonic firing cycles. Consecutive readings are compared, and the corresponding data is rejected if the readings differ by more than a predetermined amount. The rejection rate for the data is monitored and the operating speed of the navigation system is reduced if the data rejection rate is increased. This is useful to distinguish and eliminate noise from the data which truly represents the existence of an article in the field of operation of the vehicle.

  15. Error-eliminating rapid ultrasonic firing

    DOEpatents

    Borenstein, J.; Koren, Y.

    1993-08-24

    A system for producing reliable navigation data for a mobile vehicle, such as a robot, combines multiple range samples to increase the confidence'' of the algorithm in the existence of an obstacle. At higher vehicle speed, it is crucial to sample each sensor quickly and repeatedly to gather multiple samples in time to avoid a collision. Erroneous data is rejected by delaying the issuance of an ultrasonic energy pulse by a predetermined wait-period, which may be different during alternate ultrasonic firing cycles. Consecutive readings are compared, and the corresponding data is rejected if the readings differ by more than a predetermined amount. The rejection rate for the data is monitored and the operating speed of the navigation system is reduced if the data rejection rate is increased. This is useful to distinguish and eliminate noise from the data which truly represents the existence of an article in the field of operation of the vehicle.

  16. A method to evaluate the effect of contact with excipients on the surface crystallization of amorphous drugs.

    PubMed

    Zhang, Si-Wei; Yu, Lian; Huang, Jun; Hussain, Munir A; Derdour, Lotfi; Qian, Feng; de Villiers, Melgardt M

    2014-12-01

    Amorphous drugs are used to improve the solubility, dissolution, and bioavailability of drugs. However, these metastable forms of drugs can transform into more stable, less soluble, crystalline counterparts. This study reports a method for evaluating the effect of commonly used excipients on the surface crystallization of amorphous drugs and its application to two model amorphous compounds, nifedipine and indomethacin. In this method, amorphous samples of the drugs were covered by excipients and stored in controlled environments. An inverted light microscope was used to measure in real time the rates of surface crystal nucleation and growth. For nifedipine, vacuum-dried microcrystalline cellulose and lactose monohydrate increased the nucleation rate of the β polymorph from two to five times when samples were stored in a desiccator, while D-mannitol and magnesium stearate increased the nucleation rate 50 times. At 50% relative humidity, the nucleation rates were further increased, suggesting that moisture played an important role in the crystallization caused by the excipients. The effect of excipients on the crystal growth rate was not significant, suggesting that contact with excipients influences the physical stability of amorphous nifedipine mainly through the effect on crystal nucleation. This effect seems to be drug specific because for two polymorphs of indomethacin, no significant change in the nucleation rate was observed under the excipients.

  17. Quantifying weathering advance rates in basaltic andesite rinds with uranium-series isotopes: a case study from Guadeloupe

    NASA Astrophysics Data System (ADS)

    Ma, L.; Chabaux, F. J.; Pelt, E.; Granet, M.; Sak, P. B.; Gaillardet, J.; Brantley, S. L.

    2010-12-01

    Weathering of basaltic rocks plays an important role in many Earth surface processes. It is thus of great interest to quantify their weathering rates. Because of their well-documented behaviors during water-rock interaction, U-series isotopes have been shown to have utility as a potential chronometer to constrain the formation rates of weathering rinds developed on fresh basaltic rocks. In this study, U-series isotopes and trace element concentrations were analyzed in a basaltic andesite weathering rind collected from the Bras David watershed, Guadeloupe. From the clast, core and rind samples were obtained by drilling along a 63.8 mm linear profile across a low curvature segment of the core-rind boundary. Trace element concentrations reveal: significant loss of REE, Y, Rb, Sr, and Ba in the weathering rind; conservative behaviors of Ti and Th; and external addition of U into the rind during clast weathering. Measured (234U/238U) activity ratios of the rind samples are much higher than the core samples and show excess 234U. Measured (238U/232Th) and (230Th/232Th) activity ratios of the core and rind samples increase gradually from the core into the weathering rind. The observed depletion profiles for the trace elements in the clast suggest that the earliest chemical reaction that creates significant porosity is dissolution of plagioclase, consistent with the previous study [Sak et al., 2010, CG, in press]. The porosity growth within the rind allows for an influx of soil solution that carries dissolved U with (234U/238U) activity ratios >1 into the clast. The deposition of U in the rind is most likely associated with precipication of secondary minerals during clast weathering. Such a continuous U addition is responsible for the observed gradual increase of (238U/232Th) activity ratios in the rind. Subsequent production of 230Th in the rind over time from the decay of excess 234U accounts for the observed continuous increase of (230Th/232Th) activity ratios. The U-series activity ratios in the clast were modeled with a weathering advance rate of ~0.3 mm kyr-1. This represents the rind advance rate at the low curvature segment of the core-rind boundary under tropical climate. This rate is consistent with the previously estimated formation rates of basaltic rinds under similar tropic conditions in Costa Rica [Sak et al., 2004, GCA 68, 1453; Pelt et al., 2008, EPSL 276, 98]. This rate is about one order of magnitude greater than those in temperate regions, documenting the important control of temperature on basalt weathering. This work illustrates that the weathering advance rates of rinds can be successfully estimated by U-series isotopes, demonstrating their great potential as dating tools for Earth surface processes. Furthermore, U-series chronometry provides a suitable method for independently testing the hypothesis that rind advance rates around an individual clast increase with increasing interfacial curvature.

  18. Improving response rate and quality of survey data with a scratch lottery ticket incentive

    PubMed Central

    2012-01-01

    Background The quality of data collected in survey research is usually indicated by the response rate; the representativeness of the sample, and; the rate of completed questions (item-response). In attempting to improve a generally declining response rate in surveys considerable efforts are being made through follow-up mailings and various types of incentives. This study examines effects of including a scratch lottery ticket in the invitation letter to a survey. Method Questionnaires concerning oral health were mailed to a random sample of 2,400 adults. A systematically selected half of the sample (1,200 adults) received a questionnaire including a scratch lottery ticket. One reminder without the incentive was sent. Results The incentive increased the response rate and improved representativeness by reaching more respondents with lower education. Furthermore, it reduced item nonresponse. The initial incentive had no effect on the propensity to respond after the reminder. Conclusion When attempting to improve survey data, three issues become important: response rate, representativeness, and item-response. This study shows that including a scratch lottery ticket in the invitation letter performs well on all the three. PMID:22515335

  19. Technological aspects of lactose-hydrolyzed milk powder.

    PubMed

    Torres, Jansen Kelis Ferreira; Stephani, Rodrigo; Tavares, Guilherme M; de Carvalho, Antônio Fernandes; Costa, Renata Golin Bueno; de Almeida, Carlos Eduardo Rocha; Almeida, Mariana Ramos; de Oliveira, Luiz Fernando Cappa; Schuck, Pierre; Perrone, Ítalo Tuler

    2017-11-01

    Few reports describe the effect of lactose hydrolysis on the properties of milk powder during production and storage. Hence, the aim of this study was to evaluate the effects of five different levels of enzymatic lactose hydrolysis during the production and storage of milk powder. As the lactose hydrolysis rate increased, adhesion to the drying chamber also increased, due to higher levels of particle agglomeration. Additionally, more brown powder was obtained when the lactose hydrolysis rate was increased, which in turn negatively affected rehydration ability. Using Raman spectroscopy, crystallization of the lactose residues in various samples was assessed over 6weeks of accelerated aging at a room temperature environment with 75.5% of air moisture. Products with 25% or greater lactose hydrolysis showed no signs of crystallization, in contrast to the non-hydrolyzed sample. Copyright © 2017. Published by Elsevier Ltd.

  20. Bioaccumulation Study at Puffer Pond

    DTIC Science & Technology

    1994-10-01

    organism if the rate of intake of the pollutant is greater than the rate of excretion and/or metabolism . The result is an increase in body burden...PARAMETERS FOR FISH TISSUE SAMPLES Method Analyte Estimated Method Detection Limit (pg/g) ORGANOPHOSPHORUS PESTICIDES ATRAZINE 2.5 VAPONA 4.5 MALATHION

  1. Fusion neutron irradiation of Ni-Si alloys at high temperature*1

    NASA Astrophysics Data System (ADS)

    Huang, J. S.; Guinan, M. W.; Hahn, P. A.

    1988-07-01

    Two Ni-4% Si alloys, with different cold work levels, have been irradiated with 14-MeV fusion neutrons at 623 K, and their Curie temperatures have been monitored during irradiation. The results are compared to those of an identical alloy irradiated by 2-MeV electrons. The results show that increasing dislocation density increases the Curie temperature change rate. At the same damage rate, the Curie temperature change rate for the alloy irradiated by 14-MeV fusion neutrons is only 6-7% of that for an identical alloy irradiated by 2-MeV electrons. It is well known that the migration of radiation induced defects contributes to segregation of silicon atoms at sinks in this alloy, causing the Curie temperature changes. The current results imply that the relative free defect production efficiency decreases from one for the electron irradiated sample to 6-7% for the fusion neutron irradiated sample.

  2. Estimation of Nationwide Vaccination Coverage and Comparison of Interview and Telephone Survey Methodology for Estimating Vaccination Status

    PubMed Central

    Park, Boyoung; Lee, Yeon-Kyeng; Cho, Lisa Y.; Go, Un Yeong; Yang, Jae Jeong; Ma, Seung Hyun; Choi, Bo-Youl; Lee, Moo-Sik; Lee, Jin-Seok; Choi, Eun Hwa; Lee, Hoan Jong

    2011-01-01

    This study compared interview and telephone surveys to select the better method for regularly estimating nationwide vaccination coverage rates in Korea. Interview surveys using multi-stage cluster sampling and telephone surveys using stratified random sampling were conducted. Nationwide coverage rates were estimated in subjects with vaccination cards in the interview survey. The interview survey relative to the telephone survey showed a higher response rate, lower missing rate, higher validity and a less difference in vaccination coverage rates between card owners and non-owners. Primary vaccination coverage rate was greater than 90% except for the fourth dose of DTaP (diphtheria/tetanus/pertussis), the third dose of polio, and the third dose of Japanese B encephalitis (JBE). The DTaP4: Polio3: MMR1 fully vaccination rate was 62.0% and BCG1:HepB3:DTaP4:Polio3:MMR1 was 59.5%. For age-appropriate vaccination, the coverage rate was 50%-80%. We concluded that the interview survey was better than the telephone survey. These results can be applied to countries with incomplete registry and decreasing rates of landline telephone coverage due to increased cell phone usage and countries. Among mandatory vaccines, efforts to increase vaccination rate for the fourth dose of DTaP, the third dose of polio, JBE and regular vaccinations at recommended periods should be conducted in Korea. PMID:21655054

  3. Effects of strain rate and surface cracks on the mechanical behaviour of Balmoral Red granite

    PubMed Central

    Kuokkala, Veli-Tapani

    2017-01-01

    This work presents a systematic study on the effects of strain rate and surface cracks on the mechanical properties and behaviour of Balmoral Red granite. The tensile behaviour of the rock was studied at low and high strain rates using Brazilian disc samples. Heat shocks were used to produce samples with different amounts of surface cracks. The surface crack patterns were analysed using optical microscopy, and the complexity of the patterns was quantified by calculating the fractal dimensions of the patterns. The strength of the rock clearly drops as a function of increasing fractal dimensions in the studied strain rate range. However, the dynamic strength of the rock drops significantly faster than the quasi-static strength, and, because of this, also the strain rate sensitivity of the rock decreases with increasing fractal dimensions. This can be explained by the fracture behaviour and fragmentation during the dynamic loading, which is more strongly affected by the heat shock than the fragmentation at low strain rates. This article is part of the themed issue ‘Experimental testing and modelling of brittle materials at high strain rates’. PMID:27956513

  4. Examining related influential factors for dental calculus scaling utilization among people with disabilities in Taiwan, a nationwide population-based study.

    PubMed

    Lai, Hsien-Tang; Kung, Pei-Tseng; Su, Hsun-Pi; Tsai, Wen-Chen

    2014-09-01

    Limited studies with large samples have been conducted on the utilization of dental calculus scaling among people with physical or mental disabilities. This study aimed to investigate the utilization of dental calculus scaling among the national disabled population. This study analyzed the utilization of dental calculus scaling among the disabled people, using the nationwide data between 2006 and 2008. Descriptive analysis and logistic regression were performed to analyze related influential factors for dental calculus scaling utilization. The dental calculus scaling utilization rate among people with physical or mental disabilities was 16.39%, and the annual utilization frequency was 0.2 times. Utilization rate was higher among the female and non-aboriginal samples. Utilization rate decreased with increased age and disability severity while utilization rate increased with income, education level, urbanization of residential area and number of chronic illnesses. Related influential factors for dental calculus scaling utilization rate were gender, age, ethnicity (aboriginal or non-aboriginal), education level, urbanization of residence area, income, catastrophic illnesses, chronic illnesses, disability types, and disability severity significantly influenced the dental calculus scaling utilization rate. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. The Impact of Organo-Mineral Complexation on Mineral Weathering in the Soil Zone under Unsaturated Conditions

    NASA Astrophysics Data System (ADS)

    Michael, H. A.; Tan, F.; Yoo, K.; Imhoff, P. T.

    2017-12-01

    While organo-mineral complexes can protect organic matter (OM) from biodegradation, their impact on soil mineral weathering is not clear. Previous bench-scale experiments that focused on specific OM and minerals showed that the adsorption of OM to mineral surfaces accelerates the dissolution of some minerals. However, the impact of natural organo-mineral complexes on mineral dissolution under unsaturated conditions is not well known. In this study, soil samples prepared from an undisturbed forest site were used to determine mineral weathering rates under differing conditions of OM sorption to minerals. Two types of soil samples were generated: 1) soil with OM (C horizon soil from 84-100cm depth), and 2) soil without OM (the same soil as in 1) but with OM removed by heating to 350°for 24 h). Soil samples were column-packed and subjected to intermittent infiltration and drainage to mimic natural rainfall events. Each soil sample type was run in duplicate. The unsaturated condition was created by applying gas pressure to the column, and the unsaturated chemical weathering rates during each cycle were calculated from the effluent concentrations. During a single cycle, when applying the same gas pressure, soils with OM retained more moisture than OM-removed media, indicating increased water retention capacity under the impact of OM. This is consistent with the water retention data measured by evaporation experiments (HYPROP) and the dew point method (WP4C Potential Meter). Correspondingly, silicon (Si) denudation rates indicated that dissolution of silicate minerals was 2-4 times higher in OM soils, suggesting that organo-mineral complexes accelerate mineral dissolution under unsaturated conditions. When combining data from all cycles, the results showed that Si denudation rates were positively related to soil water content: denundation rate increased with increasing water content. Therefore, natural mineral chemical weathering under unsaturated conditions, while widely considered to be facilitated by biological and chemical activities, may also be affected by soil retention properties.

  6. Dynamic reservoir-condition microtomography of reactive transport in complex carbonates: Effect of initial pore structure and initial brine pH

    NASA Astrophysics Data System (ADS)

    Menke, H. P.; Bijeljic, B.; Blunt, M. J.

    2017-05-01

    We study the impact of brine acidity and initial pore structure on the dynamics of fluid/solid reaction at high Péclet numbers and low Damköhler numbers. A laboratory μ-CT scanner was used to image the dissolution of Ketton, Estaillades, and Portland limestones in the presence of CO2-acidified brine at reservoir conditions (10 MPa and 50 °C) at two injected acid strengths for a period of 4 h. Each sample was scanned between 6 and 10 times at ∼4 μm resolution and multiple effluent samples were extracted. The images were used as inputs into flow simulations, and analysed for dynamic changes in porosity, permeability, and reaction rate. Additionally, the effluent samples were used to verify the image-measured porosity changes. We find that initial brine acidity and pore structure determine the type of dissolution. Dissolution is either uniform where the porosity increases evenly both spatially and temporally, or occurs as channelling where the porosity increase is concentrated in preferential flow paths. Ketton, which has a relatively homogeneous pore structure, dissolved uniformly at pH = 3.6 but showed more channelized flow at pH = 3.1. In Estaillades and Portland, increasingly complex carbonates, channelized flow was observed at both acidities with the channel forming faster at lower pH. It was found that the effluent pH, which is higher than that injected, is a reasonably good indicator of effective reaction rate during uniform dissolution, but a poor indicator during channelling. The overall effective reaction rate was up to 18 times lower than the batch reaction rate measured on a flat surface at the effluent pH, with the lowest reaction rates in the samples with the most channelized flow, confirming that transport limitations are the dominant mechanism in determining reaction dynamics at the fluid/solid boundary.

  7. Radiation-induced insulator discharge pulses in the CRRES internal discharge monitor satellite experiment

    NASA Technical Reports Server (NTRS)

    Frederickson, A. R.; Mullen, E. G.; Brautigam, D. H.; Kerns, K. J.

    1992-01-01

    The Internal Discharge Monitor (IDM) was designed to observe electrical pulses from common electrical insulators in space service. The sixteen insulator samples included twelve planar printed circuit boards and four cables. The samples were fully enclosed, mutually isolated, and space radiation penetrated 0.02 cm of aluminum before striking the samples. Pulsing began on the seventh orbit, the maximum pulse rate occurred on the seventeenth orbit when 13 pulses occurred, and the pulses slowly diminished to about one per 3 orbits six months later. After 8 months, the radiation belts abruptly increased and the pulse rates attained a new high. These pulse rates were in agreement with laboratory experience on shorter time scales. Several of the samples never pulsed. If the pulses were not confined within IDM, the physical processes could spread to become a full spacecraft anomaly. The IDM results indicate the rate at which small insulator pulses occur. Small pulses are the seeds of larger satellite electrical anomalies. The pulse rates are compared with space radiation intensities, L shell location, and spectral distributions from the radiation spectrometers on the Combined Release and Radiation Effects Satellite.

  8. Greeks, British Greek Cypriots and Londoners: a comparison of morbidity.

    PubMed

    Mavreas, V G; Bebbington, P E

    1988-05-01

    This paper reports the results of a comparison of the rates of psychiatric disorder from three general population surveys in which the PSE-ID-CATEGO system was used for case-definition. These surveys were of an English sample in Camberwell, London, and of two Greek samples, the first in Athens, the second of Greek Cypriot immigrants living in Camberwell. The results show that the rates of psychiatric disorders in both Greek samples were somewhat higher than those of the Camberwell population, the differences being accounted for by higher rates of anxiety disorders, especially in women. Comparisons in terms of syndrome profiles showed that Greeks reported more symptoms of generalized anxiety than their English counterparts who, in their turn, reported higher rates of obsessive symptoms, and symptoms of social anxiety. The higher rates in the Greek samples were possibly due to an increased frequency of non-specific neurotic symptoms like worrying and tension. The results of other European community surveys with the PSE suggest that there might be a genuine and general North-South difference in the expression of psychological distress. Cultural differences in terms of personality traits and culturally sanctioned child rearing practices might account for the findings.

  9. Direct microscopy versus sputum cytology analysis and bleach sedimentation for diagnosis of tuberculosis: a prospective diagnostic study

    PubMed Central

    2010-01-01

    Background Diagnostic options for pulmonary tuberculosis in resource-poor settings are commonly limited to smear microscopy. We investigated whether bleach concentration by sedimentation and sputum cytology analysis (SCA) increased the positivity rate of smear microscopy for smear-positive tuberculosis. Methods We did a prospective diagnostic study in a Médecins Sans Frontières-supported hospital in Mindouli, Republic of Congo. Three sputum samples were obtained from 280 consecutive pulmonary tuberculosis suspects, and were processed according to WHO guidelines for direct smear microscopy. The remainder of each sputum sample was homogenised with 2.6% bleach, sedimented overnight, smeared, and examined blinded to the direct smear result for acid-fast bacilli (AFB). All direct smears were assessed for quality by SCA. If a patient produced fewer than three good-quality sputum samples, further samples were requested. Sediment smear examination was performed independently of SCA result on the corresponding direct smear. Positivity rates were compared using McNemar's test. Results Excluding SCA, 43.2% of all patients were diagnosed as positive on direct microscopy of up to three samples. 47.9% were diagnosed on sediment microscopy, with 48.2% being diagnosed on direct microscopy, sediment microscopy, or both. The positivity rate increased from 43.2% to 47.9% with a case definition of one positive smear (≥1 AFB/100 high power fields) of three, and from 42.1% to 43.9% with two positive smears. SCA resulted in 87.9% of patients producing at least two good-quality sputum samples, with 75.7% producing three or more. Using a case definition of one positive smear, the incremental yield of bleach sedimentation was 14/121, or 11.6% (95% CI 6.5-18.6, p = 0.001) and in combination with SCA was 15/121, or 12.4% (95% CI 7.1-19.6, p = 0.002). Incremental yields with two positive smears were 5/118, or 4.2% (95% CI 1.4-9.6, p = 0.062) and 7/118, or 5.9% (95% CI 2.4-11.8, p = 0.016), respectively. Conclusions The combination of bleach sedimentation and SCA resulted in significantly increased microscopy positivity rates with a case definition of either one or two positive smears. Implementation of bleach sedimentation led to a significant increase in the diagnosis of smear-positive patients. Implementation of SCA did not result in significantly increased diagnosis of tuberculosis, but did result in improved sample quality. Requesting extra sputum samples based on SCA results, combined with bleach sedimentation, could significantly increase the detection of smear-positive patients if routinely implemented in resource-limited settings where gold standard techniques are not available. We recommend that a pilot phase is undertaken before routine implementation to determine the impact in a particular context. PMID:20858253

  10. Method and apparatus for telemetry adaptive bandwidth compression

    NASA Technical Reports Server (NTRS)

    Graham, Olin L.

    1987-01-01

    Methods and apparatus are provided for automatic and/or manual adaptive bandwidth compression of telemetry. An adaptive sampler samples a video signal from a scanning sensor and generates a sequence of sampled fields. Each field and range rate information from the sensor are hence sequentially transmitted to and stored in a multiple and adaptive field storage means. The field storage means then, in response to an automatic or manual control signal, transfers the stored sampled field signals to a video monitor in a form for sequential or simultaneous display of a desired number of stored signal fields. The sampling ratio of the adaptive sample, the relative proportion of available communication bandwidth allocated respectively to transmitted data and video information, and the number of fields simultaneously displayed are manually or automatically selectively adjustable in functional relationship to each other and detected range rate. In one embodiment, when relatively little or no scene motion is detected, the control signal maximizes sampling ratio and causes simultaneous display of all stored fields, thus maximizing resolution and bandwidth available for data transmission. When increased scene motion is detected, the control signal is adjusted accordingly to cause display of fewer fields. If greater resolution is desired, the control signal is adjusted to increase the sampling ratio.

  11. Preparation and release study of Triclosan in polyethylene/Triclosan anti-bacterial blend.

    PubMed

    Kamalipour, Jamshid; Masoomi, Mahmood; Khonakdar, Hossein Ali; Razavi, Seyed Mohammad Reza

    2016-09-01

    In this study, medium density polyethylene (MDPE) incorporated with Triclosan antibacterial substance has been prepared and Triclosan release rate was investigated. The crystallinity level and matrix polarity, as two significant parameters in antibacterial release control, were studied. Triclosan, a well-established widespread antibacterial agent, was incorporated into medium density polyethylene (MDPE) and Maleic anhydride grafted polyethylene (PE-g-MA) was used to change the polarity of the MDPE matrix. A masterbatch of 10wt% Triclosan incorporated with the MDPE and various PE-g-MA concentrations were prepared using an internal mixer. Then the masterbatch was diluted in the MDPE matrix to produce compounds with 0.1, 0.5, and1wt% Triclosan via twin screw extruder. The compounds were molded by compression molding method and then were cooled in three different cooling rate methods: isothermal cooling (I), quenching (Q),and moderate 5-10°C/min cooling rate (M). Cooling rate effects on crystallinity level were investigated applying sample density measurement. UV-vis absorption spectroscopy was used to probe the release of Triclosan. Antibacterial properties of the compounds against Escherichia coli, Klebsiella pneumoniae, and Staphylococcus aureus were measured. The results showed that by addition of PE-g-MA, Triclosan release rate was increased. It was confirmed that the sample crystallinity was decreased by the cooling rate enhancement. The results also showed that quenched samples indicated higher release of Triclosan. Cooling rate reduction and raising the polarity increased the release of Triclosan and improved the antibacterial properties of the compounds. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Sample-size needs for forestry herbicide trials

    Treesearch

    S.M. Zedaker; T.G. Gregoire; James H. Miller

    1994-01-01

    Forest herbicide experiments are increasingly being designed to evaluate smaller treatment differences when comparing existing effective treatments, tank mix ratios, surfactants, and new low-rate products. The ability to detect small differences in efficacy is dependent upon the relationship among sample size. type I and II error probabilities, and the coefficients of...

  13. Consumer assessment of beef strip loin steaks of varying fat levels.

    PubMed

    O'Quinn, T G; Brooks, J C; Polkinghorne, R J; Garmyn, A J; Johnson, B J; Starkey, J D; Rathmann, R J; Miller, M F

    2012-02-01

    A consumer study was conducted in Lubbock, Texas, to determine the effects of fat level of beef strip steaks on the palatability traits of tenderness, juiciness, flavor liking, and overall liking, while further investigating the window of acceptability for fat content of beef. Thirty beef strip loins were selected by trained personnel to equally represent USDA Prime, High Choice (upper 1/3 Choice), Low Choice (lower 1/3 Choice), Select, and Standard. Proximate analysis was conducted on all strip loins to determine percentage fat, moisture, protein, and collagen. Three strip loins from each quality grade were selected based on fat percentages from proximate analysis to best represent each USDA quality grade for use in the consumer evaluations. Strip loins were fabricated into 2.5-cm steaks, and further processed into 5 × 5 cm pieces. In addition to the US-sourced product, beef LM pieces from 6 Australian Wagyu steers (Wagyu) and 6 Australian grain finished steers (Australian) were used in the consumer evaluations. Consumers (n = 120) were served 7 samples: a warm-up sample, 1 sample from each USDA quality grade treatment, and either a Wagyu or Australian sample, in a balanced order in accordance with a 6 × 6 Latin square. Consumers rated each steak sample for tenderness, juiciness, flavor, and overall liking and rated each palatability trait as either acceptable or unacceptable. Moreover, consumers rated each sample as unsatisfactory, good everyday quality, better than everyday quality, or premium quality. Tenderness, juiciness, flavor liking, and overall liking increased with increasing fat content (P < 0.05). However, Wagyu and Australian samples did not follow this trend for flavor and overall liking. A decrease in consumer acceptability of each palatability trait was observed as fat level decreased (P < 0.05). Consumer overall liking was correlated (P < 0.05) with consumer tenderness (r = 0.76) and juiciness ratings (r = 0.73), but most highly correlated with flavor liking (r = 0.88). Results of this study indicated that increased fat level in beef strip steaks positively affected tenderness, juiciness, flavor liking, and overall liking of beef strip steaks. Moreover, flavor liking was the most highly correlated palatability trait with overall liking. In US-sourced samples, fat level had a large effect on the flavor liking of beef as determined by consumers.

  14. The self-similar turbulent flow of low-pressure water vapor

    NASA Astrophysics Data System (ADS)

    Konyukhov, V. K.; Stepanov, E. V.; Borisov, S. K.

    2018-05-01

    We studied turbulent flows of water vapor in a pipe connecting two closed vessels of equal volume. The vessel that served as a source of water vapor was filled with adsorbent in the form of corundum ceramic balls. These ceramic balls were used to obtain specific conditions to lower the vapor pressure in the source vessel that had been observed earlier. A second vessel, which served as a receiver, was empty of either air or vapor before each vapor sampling. The rate of the pressure increase in the receiver vessel was measured in a series of six samplings performed with high precision. The pressure reduction rate in the source vessel was found to be three times lower than the pressure growth rate in the receiver vessel. We found that the pressure growth rates in all of the adjacent pairs of samples could be arranged in a combination that appeared to be identical for all pairs, and this revealed the existence of a rather interesting and peculiar self-similarity law for the sampling processes under consideration.

  15. Non-stimulated adrenal venous sampling using Dyna computed tomography in patients with primary aldosteronism

    PubMed Central

    Chang, Chin-Chen; Lee, Bo-Ching; Liu, Kao-Lang; Chang, Yeun-Chung; Wu, Vin-Cent; Huang, Kuo-How

    2016-01-01

    In this retrospective study, we aimed to examine the effect of applying Dyna computed tomography (CT) on the success rate of adrenal venous sampling (AVS) without adrenocorticotropic hormone stimulation. A total of 100 consecutive patients with primary aldosteronism who underwent AVS between May 2012 and July 2015 were enrolled. In all the cases, Dyna CT was used in AVS to validate catheter position in the right adrenal vein. A selectivity index (cortisoladrenal vein /cortisolinferior vena cava) of ≥2.0 of both adrenal veins were required for successful AVS. Dyna CT indicated misplaced catheters in 16 patients; of these patients, 75% (12/16) eventually had successful right AVS after catheter repositioning. The success rate of initial sampling at the right adrenal vein was 76% (76/100), which increased to 88% (88/100) after Dyna CT was applied (p < 0.001). The most common inadvertently catheterised vessels detected using Dyna CT were the accessory hepatic veins (56.3%, 9/16), followed by the renal capsular veins (37.5%, 6/16). The overall success rate of non-stimulated AVS using Dyna CT was 87% (87/100). Thus, the application of Dyna CT further increased the success rate of non-stimulated AVS. PMID:27876824

  16. Characteristics and influencing factors of tetrachloroethylene sorption-desorption on soil and its components.

    PubMed

    Qiu, Zhaofu; Yang, Weiwei; He, Long; Zhao, Zhexuan; Lu, Shuguang; Sui, Qian

    2016-02-01

    To investigate the effects of soil structure, soil organic carbon (SOC), minerals, initial tetrachloroethylene (PCE) concentration (C0), and ionic strength (Ci) on PCE sorption-desorption, six types of soil were adopted as adsorbents, including two types of natural soil and four types of soil with most of the "soft carbon" pre-treated by H2O2 or with all SOC removed from the original soil by 600 °C ignition. The results showed that all of the sorption-desorption isotherms of PCE were non-linear within the experimental range, and the H2O2-treated samples exhibited higher non-linear sorption isotherms than those of the original soils. The hysteresis index of PCE sorption to original soil is less pronounced than that of the H2O2-treated and 600 °C-heated samples due to the entrapment of sorbate molecules in the "hard carbon" domain, together with the meso- and microporous structures within the 600 °C-heated samples. Both SOC and minerals have impacts on the sorption-desorption of PCE, and the sorption-desorption contribution rate of minerals increased with decreasing SOC content. C0 has almost no influence on the sorption to minerals of the soils, but the contribution rate of minerals decreased with increasing C0 in the desorption stage. As a result of the salting-out effect, PCE sorption capacity was increased by increasing Ci, especially when Ci ≥ 0.1 M. Moreover, desorption increased and hysteresis weakened with increasing Ci, except for the 600 °C-heated samples. In addition, no significant effect of Ci on desorption of PCE and no hysteresis was observed in this experimental range for the 600 °C-heated samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. An evaluation of population index and estimation techniques for tadpoles in desert pools

    USGS Publications Warehouse

    Jung, Robin E.; Dayton, Gage H.; Williamson, Stephen J.; Sauer, John R.; Droege, Sam

    2002-01-01

    Using visual (VI) and dip net indices (DI) and double-observer (DOE), removal (RE), and neutral red dye capture-recapture (CRE) estimates, we counted, estimated, and censused Couch's spadefoot (Scaphiopus couchii) and canyon treefrog (Hyla arenicolor) tadpole populations in Big Bend National Park, Texas. Initial dye experiments helped us determine appropriate dye concentrations and exposure times to use in mesocosm and field trials. The mesocosm study revealed higher tadpole detection rates, more accurate population estimates, and lower coefficients of variation among pools compared to those from the field study. In both mesocosm and field studies, CRE was the best method for estimating tadpole populations, followed by DOE and RE. In the field, RE, DI, and VI often underestimated populations in pools with higher tadpole numbers. DI improved with increased sampling. Larger pools supported larger tadpole populations, and tadpole detection rates in general decreased with increasing pool volume and surface area. Hence, pool size influenced bias in tadpole sampling. Across all techniques, tadpole detection rates differed among pools, indicating that sampling bias was inherent and techniques did not consistently sample the same proportion of tadpoles in each pool. Estimating bias (i.e., calculating detection rates) therefore was essential in assessing tadpole abundance. Unlike VI and DOE, DI, RE, and CRE could be used in turbid waters in which tadpoles are not visible. The tadpole population estimates we used accommodated differences in detection probabilities in simple desert pool environments but may not work in more complex habitats.

  18. Kinetics of thermal and photo-initiated release of tris (1,3-dichloro-2-propyl) phosphate (TDCP) flame retardant from polyurethane foam materials.

    PubMed

    Ghanem, Raed A

    2015-01-01

    Kinetics of thermal and photo-initiated release of Tris (1.3-dichloro-2-propyl) phosphate (TDCP) from the polyurethane foam (PUF) materials were studied using a validated chromatographic method with linear calibration curve in the range of 0.03-400 μg mL(-1). Time dependence of TDCP leaching from foam samples was found to follow first-order kinetics; with rate constants directly dependent on ageing temperatures and intensity of UV radiation, rate constants for the thermally and photo initiated were 3.6 × 10(-3), 1.03 × 10(-2), 3.6 × 10(-2) and 3.94 × 10(-2) day(-1), respectively. Migration of TDCP from foam samples simulating skin or oral exposure were observed from all samples regardless of their ageing history, the presence of biological fluids found to enhance the migration rate. Oral exposure to foam material contains TDCP, which was simulated using the Head-over-Heels test, reveals that an average amount of ∼ 1.7% wt./wt. of the total amount of TDCP was found to leach into biological fluids, and it significantly increased to ∼ 6.0% wt./wt. due to ageing conditions. Direct contact between foam material and skin simulated by using the Contact Blotting test reveals that TDCP is transferred from both aged and un-aged samples at different rates, due to the presence of biological fluids; the transferred amount is increased with ageing conditions.

  19. Changes in U.S. Hospitalization and Mortality Rates following Smoking Bans

    ERIC Educational Resources Information Center

    Shetty, Kanaka D.; DeLeire, Thomas; White, Chapin; Bhattacharya, Jayanta

    2011-01-01

    U.S. state and local governments have increasingly adopted restrictions on smoking in public places. This paper analyzes nationally representative databases, including the Nationwide Inpatient Sample, to compare short-term changes in mortality and hospitalization rates in smoking-restricted regions with control regions. In contrast with smaller…

  20. A Systematic Review and Meta-Analysis Estimating the Expected Dropout Rates in Randomized Controlled Trials on Yoga Interventions.

    PubMed

    Cramer, Holger; Haller, Heidemarie; Dobos, Gustav; Lauche, Romy

    2016-01-01

    A reasonable estimation of expected dropout rates is vital for adequate sample size calculations in randomized controlled trials (RCTs). Underestimating expected dropouts rates increases the risk of false negative results while overestimating rates results in overly large sample sizes, raising both ethical and economic issues. To estimate expected dropout rates in RCTs on yoga interventions, MEDLINE/PubMed, Scopus, IndMED, and the Cochrane Library were searched through February 2014; a total of 168 RCTs were meta-analyzed. Overall dropout rate was 11.42% (95% confidence interval [CI] = 10.11%, 12.73%) in the yoga groups; rates were comparable in usual care and psychological control groups and were slightly higher in exercise control groups (rate = 14.53%; 95% CI = 11.56%, 17.50%; odds ratio = 0.82; 95% CI = 0.68, 0.98; p = 0.03). For RCTs with durations above 12 weeks, dropout rates in yoga groups increased to 15.23% (95% CI = 11.79%, 18.68%). The upper border of 95% CIs for dropout rates commonly was below 20% regardless of study origin, health condition, gender, age groups, and intervention characteristics; however, it exceeded 40% for studies on HIV patients or heterogeneous age groups. In conclusion, dropout rates can be expected to be less than 15 to 20% for most RCTs on yoga interventions. Yet dropout rates beyond 40% are possible depending on the participants' sociodemographic and health condition.

  1. A Systematic Review and Meta-Analysis Estimating the Expected Dropout Rates in Randomized Controlled Trials on Yoga Interventions

    PubMed Central

    Haller, Heidemarie; Dobos, Gustav; Lauche, Romy

    2016-01-01

    A reasonable estimation of expected dropout rates is vital for adequate sample size calculations in randomized controlled trials (RCTs). Underestimating expected dropouts rates increases the risk of false negative results while overestimating rates results in overly large sample sizes, raising both ethical and economic issues. To estimate expected dropout rates in RCTs on yoga interventions, MEDLINE/PubMed, Scopus, IndMED, and the Cochrane Library were searched through February 2014; a total of 168 RCTs were meta-analyzed. Overall dropout rate was 11.42% (95% confidence interval [CI] = 10.11%, 12.73%) in the yoga groups; rates were comparable in usual care and psychological control groups and were slightly higher in exercise control groups (rate = 14.53%; 95% CI = 11.56%, 17.50%; odds ratio = 0.82; 95% CI = 0.68, 0.98; p = 0.03). For RCTs with durations above 12 weeks, dropout rates in yoga groups increased to 15.23% (95% CI = 11.79%, 18.68%). The upper border of 95% CIs for dropout rates commonly was below 20% regardless of study origin, health condition, gender, age groups, and intervention characteristics; however, it exceeded 40% for studies on HIV patients or heterogeneous age groups. In conclusion, dropout rates can be expected to be less than 15 to 20% for most RCTs on yoga interventions. Yet dropout rates beyond 40% are possible depending on the participants' sociodemographic and health condition. PMID:27413387

  2. Estimating sedimentation rates and sources in a partially urbanized catchment using caesium-137

    NASA Astrophysics Data System (ADS)

    Ormerod, L. M.

    1998-06-01

    While there has been increased interest in determining sedimentation rates and sources in agricultural and forested catchments in recent years, there have been few studies dealing with urbanized catchments. A study of sedimentation rates and sources within channel and floodplain deposits of a partially urbanized catchment has been undertaken using the 137Cs technique. Results for sedimentation rates showed no particular downstream pattern. This may be partially explained by underestimation of sedimentation rates at some sites by failure to sample the full 137Cs profile, floodplain erosion and deliberate removal of sediment. Evidence of lateral increases in net sedimentation rates with distance from the channel may be explained by increased floodplain erosion at sites closer to the channel and floodplain formation by lateral deposition. Potential sediment sources for the catchment were considered to be forest topsoil, subsurface material and sediments derived from urban areas, which were found to be predominantly subsurface material. Tracing techniques showed an increase in subsurface material for downstream sites, confirming expectations that subsurface material would increase in the downstream direction in response to the direct and indirect effects of urbanization.

  3. Admission rates and costs associated with emergency presentation of urolithiasis: analysis of the Nationwide Emergency Department Sample 2006-2009.

    PubMed

    Eaton, Samuel H; Cashy, John; Pearl, Jeffrey A; Stein, Daniel M; Perry, Kent; Nadler, Robert B

    2013-12-01

    We sought to examine a large nationwide (United States) sample of emergency department (ED) visits to determine data related to utilization and costs of care for urolithiasis in this setting. Nationwide Emergency Department Sample was analyzed from 2006 to 2009. All patients presenting to the ED with a diagnosis of upper tract urolithiasis were analyzed. Admission rates and total cost were compared by region, hospital type, and payer type. Numbers are weighted estimates that are designed to approximate the total national rate. An average of 1.2 million patients per year were identified with the diagnosis of urolithiasis out of 120 million visits to the ED annually. Overall average rate of admission was 19.21%. Admission rates were highest in the Northeast (24.88%), among teaching hospitals (22.27%), and among Medicare patients (42.04%). The lowest admission rates were noted for self-pay patients (9.76%) and nonmetropolitan hospitals (13.49%). The smallest increases in costs over time were noted in the Northeast. Total costs were least in nonmetropolitan hospitals; however, more patients were transferred to other hospitals. When assessing hospital ownership status, private for-profit hospitals had similar admission rates compared with private not-for-profit hospitals (16.6% vs 15.9%); however, costs were 64% and 48% higher for ED and inpatient admission costs, respectively. Presentation of urolithiasis to the ED is common, and is associated with significant costs to the medical system, which are increasing over time. Costs and rates of admission differ by region, payer type, and hospital type, which may allow us to identify the causes for cost discrepancies and areas to improve efficiency of care delivery.

  4. Applying Reactive Barrier Technology to Enhance Microbially-mediated Denitrification during Managed Aquifer Recharge

    NASA Astrophysics Data System (ADS)

    Beganskas, S.; Weir, W. B.; Harmon, R. E.; Gorski, G.; Fisher, A. T.; Saltikov, C.; Young, K. S.; Runneals, D.; Teo, E. K.; Stoneburner, B.; Hernandez, J.

    2015-12-01

    We are running field experiments to observe and quantify microbially-mediated water quality improvement via denitrification during infiltration in the shallow subsurface. Nitrate is a pervasive groundwater contaminant, and nitrate removal through denitrification can occur during infiltration in natural and anthropogenic systems, including during managed aquifer recharge (MAR). The rate of denitrification can vary depending on factors such as infiltration rate; previous work suggests that denitrification rates can increase monotonically with infiltration rates until reaching a critical threshold. We are performing controlled field tests of variables that affect denitrification rate, including sampling to link water chemistry changes to microbial ecology and activity. This study explores how microbial activity and denitrification rates respond to different infiltration rates and the presence or absence of a reactive material (wood chips, a carbon source). We are conducting four two-week-long tests, each under different conditions. For each test, we measure bulk infiltration rate (the sum of lateral and vertical infiltration), vertical infiltration rate using heat as a tracer, and water level. We collect surface and subsurface water samples daily, and we collect soil samples at the start and end of each test. For each water sample, we are measuring NO3-, NO2-, NH3, DOC, and N and O isotopes in nitrate. Soil samples will be tested for grain size, total C/N, and the presence of microbiological genes associated with denitrification. These results will expand our knowledge of the conditions under which denitrification occurs by implicating specific microorganisms and physical infiltration parameters. Our design has the potential for additional experimentation with variables that impact water chemistry during infiltration. This study has broad applications for designing MAR systems that effectively improve water supply and water quality.

  5. Fall-related injuries among Canadian seniors, 2005–2013: an analysis of the Canadian Community Health Survey

    PubMed Central

    Do, M. T.; Chang, V. C.; Kuran, N.; Thompson, W.

    2015-01-01

    Abstract Introduction: We describe the epidemiology and trends of fall-related injuries among Canadian seniors aged 65 years and older by sex and age, as well as the circumstances and consequences of their injuries. Methods: We analyzed nationally representative data from the 2005, 2009/2010 and 2013 samples of the Canadian Community Health Survey to calculate the number and rates of fall-related injuries for each survey year. Where possible, we combined data from two or more samples to estimate the proportion of fall-related injuries by type of injury, part of body injured, type of activity and type of treatment. Results: The rate of fall-related injuries among seniors increased from 49.4 to 58.8 per 1000 population between 2005 and 2013, during which the number of fall-related injuries increased by 54% overall. Women had consistently higher rates than men across all survey years, while rates increased with advancing age. The upward trend in fall-related injury rates was more prominent among women and younger age groups. The most common type of injury was broken or fractured bones (37%), and the shoulder or upper arm (16%) was the most commonly injured body part. Many fall-related injuries occurred while walking on a surface other than snow or ice (45%). Over 70% of seniors seeking treatment for their injuries visited a hospital emergency department. Conclusion: Given the increase in both the number and rates of fall-related injuries over time, there is a need to continue monitoring trends and injury patterns associated with falls. PMID:26378768

  6. Fall-related injuries among Canadian seniors, 2005-2013: an analysis of the Canadian Community Health Survey.

    PubMed

    Do, M T; Chang, V C; Kuran, N; Thompson, W

    2015-09-01

    We describe the epidemiology and trends of fall-related injuries among Canadian seniors aged 65 years and older by sex and age, as well as the circumstances and consequences of their injuries. We analyzed nationally representative data from the 2005, 2009/2010 and 2013 samples of the Canadian Community Health Survey to calculate the number and rates of fall-related injuries for each survey year. Where possible, we combined data from two or more samples to estimate the proportion of fall-related injuries by type of injury, part of body injured, type of activity and type of treatment. The rate of fall-related injuries among seniors increased from 49.4 to 58.8 per 1000 population between 2005 and 2013, during which the number of fall-related injuries increased by 54% overall. Women had consistently higher rates than men across all survey years, while rates increased with advancing age. The upward trend in fall-related injury rates was more prominent among women and younger age groups. The most common type of injury was broken or fractured bones (37%), and the shoulder or upper arm (16%) was the most commonly injured body part. Many fall-related injuries occurred while walking on a surface other than snow or ice (45%). Over 70% of seniors seeking treatment for their injuries visited a hospital emergency department. Given the increase in both the number and rates of fall-related injuries over time, there is a need to continue monitoring trends and injury patterns associated with falls.

  7. Corrosion behavior of sensitized duplex stainless steel.

    PubMed

    Torres, F J; Panyayong, W; Rogers, W; Velasquez-Plata, D; Oshida, Y; Moore, B K

    1998-01-01

    The present work investigates the corrosion behavior of 2205 duplex stainless steel in 0.9% NaCl solution after various heat-treatments, and compares it to that of 316L austenitic stainless steel. Both stainless steels were heat-treated at 500, 650, and 800 degrees C in air for 1 h, followed by furnace cooling. Each heat-treated sample was examined for their microstructures and Vickers micro-hardness, and subjected to the X-ray diffraction for the phase identification. Using potentiostatic polarization method, each heat-treated sample was corrosion-tested in 37 degrees C 0.9% NaCl solution to estimate its corrosion rate. It was found that simulated sensitization showed an adverse influence on both steels, indicating that corrosion rates increased by increasing the sensitization temperatures.

  8. Finite mixture model: A maximum likelihood estimation approach on time series data

    NASA Astrophysics Data System (ADS)

    Yen, Phoong Seuk; Ismail, Mohd Tahir; Hamzah, Firdaus Mohamad

    2014-09-01

    Recently, statistician emphasized on the fitting of finite mixture model by using maximum likelihood estimation as it provides asymptotic properties. In addition, it shows consistency properties as the sample sizes increases to infinity. This illustrated that maximum likelihood estimation is an unbiased estimator. Moreover, the estimate parameters obtained from the application of maximum likelihood estimation have smallest variance as compared to others statistical method as the sample sizes increases. Thus, maximum likelihood estimation is adopted in this paper to fit the two-component mixture model in order to explore the relationship between rubber price and exchange rate for Malaysia, Thailand, Philippines and Indonesia. Results described that there is a negative effect among rubber price and exchange rate for all selected countries.

  9. One-day rate measurements for estimating net nitrification potential in humid forest soils

    USGS Publications Warehouse

    Ross, D.S.; Fredriksen, G.; Jamison, A.E.; Wemple, B.C.; Bailey, S.W.; Shanley, J.B.; Lawrence, G.B.

    2006-01-01

    Measurements of net nitrification rates in forest soils have usually been performed by extended sample incubation (2-8 weeks), either in the field or in the lab. Because of disturbance effects, these measurements are only estimates of nitrification potential and shorter incubations may suffice. In three separate studies of northeastern USA forest soil surface horizons, we found that laboratory nitrification rates measured over 1 day related well to those measured over 4 weeks. Soil samples of Oa or A horizons were mixed by hand and the initial extraction of subsamples, using 2 mol L-1 KCl, occurred in the field as soon as feasible after sampling. Soils were kept near field temperature and subsampled again the following day in the laboratory. Rates measured by this method were about three times higher than the 4-week rates. Variability in measured rates was similar over either incubation period. Because NO3- concentrations were usually quite low in the field, average rates from 10 research watersheds could be estimated with only a single, 1-day extraction. Methodological studies showed that the concentration of NH4+ increased slowly during contact time with the KCl extractant and, thus, this contact time should be kept similar during the procedure. This method allows a large number of samples to be rapidly assessed. ?? 2006 Elsevier B.V. All rights reserved.

  10. Ethanol emission from loose corn silage and exposed silage particles

    NASA Astrophysics Data System (ADS)

    Hafner, Sasha D.; Montes, Felipe; Rotz, C. Alan; Mitloehner, Frank

    2010-11-01

    Silage on dairy farms has been identified as a major source of volatile organic compound (VOC) emissions. However, rates of VOC emission from silage are not accurately known. In this work, we measured ethanol (a dominant silage VOC) emission from loose corn silage and exposed corn silage particles using wind tunnel systems. Flux of ethanol was highest immediately after exposing loose silage samples to moving air (as high as 220 g m -2 h -1) and declined by as much as 76-fold over 12 h as ethanol was depleted from samples. Emission rate and cumulative 12 h emission increased with temperature, silage permeability, exposed surface area, and air velocity over silage samples. These responses suggest that VOC emission from silage on farms is sensitive to climate and management practices. Ethanol emission rates from loose silage were generally higher than previous estimates of total VOC emission rates from silage and mixed feed. For 15 cm deep loose samples, mean cumulative emission was as high as 170 g m -2 (80% of initial ethanol mass) after 12 h of exposure to an air velocity of 5 m s -1. Emission rates measured with an emission isolation flux chamber were lower than rates measured in a wind tunnel and in an open setting. Results show that the US EPA emission isolation flux chamber method is not appropriate for estimating VOC emission rates from silage in the field.

  11. The Microstructure Evolution of a Fe₃Al Alloy during the LENS Process.

    PubMed

    Karczewski, Krzysztof; Durejko, Tomasz; Czujko, Tomasz

    2018-03-07

    A Fe₃Al intermetallic alloy has been successfully prepared by the laser-engineered net shaping (LENS) process. The applied process parameters were selected to provide various cooling rates during the solidification of the laser-melted material. The macro- and microstructure and the micro- and macrotexture of Fe₃Al samples were investigated. The influence of the cooling rate on grain morphology and texture is discussed. For the applied cooling rate range of 0.64 × 10⁴ K/s-2.6 × 10⁴ K/s, the structure is characterized by the presence of columnar grains for which the growth is directed upwards from the substrate. The intensity of the microtexture varies with the height of the sample and the cooling rate. The intensity of the texture increases with the decrease in the cooling rate. The samples that were obtained with low and medium cooling rates are characterized by the well-developed <100> and <111> macrotextures. The Fe₃Al alloy that was produced with a high cooling rate did not show a specific texture, which is reflected in the fairly uniform distribution of the normalized density intensity. Only a very weak texture with a <100> type component was observed.

  12. Solubilization of the poorly water soluble drug, telmisartan, using supercritical anti-solvent (SAS) process.

    PubMed

    Park, Junsung; Cho, Wonkyung; Cha, Kwang-Ho; Ahn, Junhyun; Han, Kang; Hwang, Sung-Joo

    2013-01-30

    Telmisartan is a biopharmaceutical classification system (BCS) class II drug that has extremely low water solubility but is freely soluble in highly alkalized solutions. Few organic solvents can dissolve telmisartan. This solubility problem is the main obstacle achieving the desired bioavailability. Because of its unique characteristics, the supercritical anti-solvent (SAS) process was used to BCS class II drug in a variety of ways including micronization, amorphization and solid dispersion. Solid dispersions were prepared using hydroxypropylmethylcellulose/polyvinylpyrrolidone (HPMC/PVP) at 1:0.5, 1:1, and 1:2 weight ratios of drug to polymer, and pure telmisartan was also treated using the SAS process. Processed samples were characterized for morphology, particle size, crystallinity, solubility, dissolution rate and polymorphic stability. After the SAS process, all samples were converted to the amorphous form and were confirmed to be hundreds nm in size. Solubility and dissolution rate were increased compared to the raw material. Solubility tended to increase with increases in the amount of polymer used. However, unlike the solubility results, the dissolution rate decreased with increases in polymer concentration due to gel layer formation of the polymer. Processed pure telmisartan showed the best drug release even though it had lower solubility compared to other solid dispersions; however, because there were no stabilizers in processed pure telmisartan, it recrystallized after 1 month under severe conditions, while the other solid dispersion samples remained amorphous form. We conclude that after controlling the formulation of solid dispersion, the SAS process could be a promising approach for improving the solubility and dissolution rate of telmisartan. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. When Is Rapid On-Site Evaluation Cost-Effective for Fine-Needle Aspiration Biopsy?

    PubMed Central

    Schmidt, Robert L.; Walker, Brandon S.; Cohen, Michael B.

    2015-01-01

    Background Rapid on-site evaluation (ROSE) can improve adequacy rates of fine-needle aspiration biopsy (FNAB) but increases operational costs. The performance of ROSE relative to fixed sampling depends on many factors. It is not clear when ROSE is less costly than sampling with a fixed number of needle passes. The objective of this study was to determine the conditions under which ROSE is less costly than fixed sampling. Methods Cost comparison of sampling with and without ROSE using mathematical modeling. Models were based on a societal perspective and used a mechanistic, micro-costing approach. Sampling policies (ROSE, fixed) were compared using the difference in total expected costs per case. Scenarios were based on procedure complexity (palpation-guided or image-guided), adequacy rates (low, high) and sampling protocols (stopping criteria for ROSE and fixed sampling). One-way, probabilistic, and scenario-based sensitivity analysis was performed to determine which variables had the greatest influence on the cost difference. Results ROSE is favored relative to fixed sampling under the following conditions: (1) the cytologist is accurate, (2) the total variable cost ($/hr) is low, (3) fixed costs ($/procedure) are high, (4) the setup time is long, (5) the time between needle passes for ROSE is low, (6) when the per-pass adequacy rate is low, and (7) ROSE stops after observing one adequate sample. The model is most sensitive to variation in the fixed cost, the per-pass adequacy rate, and the time per needle pass with ROSE. Conclusions Mathematical modeling can be used to predict the difference in cost between sampling with and without ROSE. PMID:26317785

  14. Perception of melting and flavor release of ice cream containing different types and contents of fat.

    PubMed

    Hyvönen, L; Linna, M; Tuorila, H; Dijksterhuis, G

    2003-04-01

    Temporal effects of dairy and vegetable fats (0 to 18%) on perception of strawberry flavor release and melting of ice cream were studied using the time intensity sensory method. Also, aroma and flavor attributes of the ice cream samples were evaluated. Only slight effects of fat on the rate of flavor release and flavor intensity were perceived. A slightly faster flavor release from the vegetable fat compared with dairy fat was noticed. Polydextrose and maltodextrin as bodying agents in the fat-free ice cream significantly increased flavor release and melting rate of the ice cream. Increasing fat content slightly retarded melting of ice cream in the mouth. No significant effect of the fat quality on perceived melting was noticed. Significant differences in aroma and flavor attributes of the fat-free and other samples were perceived. Intensity and sharpness of the strawberry aroma and flavor were greater in fat-free samples and they were perceived as nontypical. Fattiness and creaminess were highly correlated. Maltodextrin and polydextrose increased perceived fattiness and creaminess of fat-free ice cream.

  15. Development of carbon dioxide adsorbent from rice husk char

    NASA Astrophysics Data System (ADS)

    Abang, S.; Janaun, J.; Anisuzzaman, S. M.; Ikhwan, F. S.

    2016-06-01

    This study was mainly concerned about the development of carbon dioxide (CO2) adsorbent from rice husk (RH). Several chemical treatments were used to produce activated rice husk char (RHAC) from RH. Initially the RH was refluxed with 3M of sodium hydroxide (NaOH) solution, activation followed by using 0.5M of zinc chloride (ZnCl2) solution and finally acidic treatment by using 0.1M of hydrochloric acid (HCl). Then, the RHAC was functionalized by using 3-chloropropylamine hydrochloride (3-CPA) and noted as RHN. RHN samples were characterized with scanning electron microscopy (SEM), mercury intrusion porosimetry (MIP), fourier transform infrared spectroscopy (FTIR). Based on the SEM, the RHN sample had a large pore diameter compared to RH sample after being treated. Based on MIP data, the average pore diameter between RH and RHAC samples were increased significantly from 0.928 microns to 1.017 microns. The RHN sample also had higher total porosity (%) compared to RHAC and RH (58.45%, 47.82% and 45.57% respectively). The total specific surface area of the sample was much increasing from RHO to RHAC (29.17 m2/g and 62.94 m2/g respectively) and slightly being decreasing from RHAC to RHN (58.88 m2/g). FTIR result showed the present of weak band at 1587 cm-1 which demonstrating of the amine group present on the sample. The CO2 capture result showed that the decreasing of operating temperature can increase the breakthrough time of CO2 capture. On the contrary decreasing of CO2 gas flow rate can increase the breakthrough time of CO2 capture. The highest total amount of CO2 adsorbed was 25338.57 mg of CO2/g of RHN sample by using 100 mL/min of gas flow rate at 30oC. Based on adsorption isotherm analysis, the Freundlich isotherm was the best isotherm to describe the CO2 adsorption on the sample.

  16. Determinants of job turnover of young men and women in the United States: a hazard rate analysis.

    PubMed

    Donohue, J J

    1988-01-01

    Hazard models were used to examine the expected job tenure of male and female entrants to the full-time labor force after they appear to have completed their full-time education. Other analysts who have examined the relative quit rates of men and women have not limited their analyses to the 1st job, but they have implicitly assumed that hazard rates from 1st jobs are completely representative of hazard rates from any random nth job. This is 1 of the most important and questionable aspects of their implicit assumption that job terminations can be treated in semi-Markov processes. The basic goal is to analyze the hazard rates for a set of workers who have in some sense terminated their primary tie to education and have shifted toward a primary commitment to the labor force. The compilation of the durations of 1st full-time (20 or more hours/week) jobs yielded a sample of 1431 men and 1527 women. Female workers on average had about a half-year less education than the men: 12.47 years compared to 12.89 years. The percentage of workers with less than a high school education was similar for men (18.1%) and women (18.6%). The percentage of workers with 18 or more years of education was almost 6 times as high for men as for women: 2.73% versus 0.46%. The racial composition of the sample reflected the higher labor force participation rates of black women over white women. For the male sample, 73.2% of the workers were white and 25.7% were black. For the female sample, 70.7% were white and 28.3% were black. For the period 1968-71, female full-time workers quit their 1st job after completing school at substantially higher rates than male workers. This finding was robust to several different model specifications and selection criteria, as well as to estimations with and without duration dependence and with and without corrections for unobserved heterogeneity. While changes were not marked, increasing the definition of full-time employment from 20-30 hours reduced overall quit rates and tended to widen the tenure gap between men and women workers. Treating layoffs as completed spells of work raised overall quit rates and tended to narrow slightly the male-female tenure differential. Also contrary to the other microdata studies, the following were among the results: increased education had a significant and negative effect on quitting for both men and women; the unemployment rate had a significant, negative effect on quit rates for men; the hazard rates for women did not decline monotonically with duration but increased sharply after 18 months; and nonwhites did not have lower rates than whites.

  17. Probing the water distribution in porous model sands with two immiscible fluids: A nuclear magnetic resonance micro-imaging study

    NASA Astrophysics Data System (ADS)

    Lee, Bum Han; Lee, Sung Keun

    2017-10-01

    The effect of the structural heterogeneity of porous networks on the water distribution in porous media, initially saturated with immiscible fluid followed by increasing durations of water injection, remains one of the important problems in hydrology. The relationship among convergence rates (i.e., the rate of fluid saturation with varying injection time) and the macroscopic properties and structural parameters of porous media have been anticipated. Here, we used nuclear magnetic resonance (NMR) micro-imaging to obtain images (down to ∼50 μm resolution) of the distribution of water injected for varying durations into porous networks that were initially saturated with silicone oil. We then established the relationships among the convergence rates, structural parameters, and transport properties of porous networks. The volume fraction of the water phase increases as the water injection duration increases. The 3D images of the water distributions for silica gel samples are similar to those of the glass bead samples. The changes in water saturation (and the accompanying removal of silicone oil) and the variations in the volume fraction, specific surface area, and cube-counting fractal dimension of the water phase fit well with the single-exponential recovery function { f (t) = a [ 1 -exp (- λt) ] } . The asymptotic values (a, i.e., saturated value) of the properties of the volume fraction, specific surface area, and cube-counting fractal dimension of the glass bead samples were greater than those for the silica gel samples primarily because of the intrinsic differences in the porous networks and local distribution of the pore size and connectivity. The convergence rates of all of the properties are inversely proportional to the entropy length and permeability. Despite limitations of the current study, such as insufficient resolution and uncertainty for the estimated parameters due to sparsely selected short injection times, the observed trends highlight the first analyses of the cube-counting fractal dimension (and other structural properties) and convergence rates in porous networks consisting of two fluid components. These results indicate that the convergence rates correlate with the geometric factor that characterizes the porous networks and transport property of the porous networks.

  18. Non-linear patterns in age-related DNA methylation may reflect CD4+ T cell differentiation

    PubMed Central

    Johnson, Nicholas D.; Wiener, Howard W.; Smith, Alicia K.; Nishitani, Shota; Absher, Devin M.; Arnett, Donna K.; Aslibekyan, Stella; Conneely, Karen N.

    2017-01-01

    ABSTRACT DNA methylation (DNAm) is an important epigenetic process involved in the regulation of gene expression. While many studies have identified thousands of loci associated with age, few have differentiated between linear and non-linear DNAm trends with age. Non-linear trends could indicate early- or late-life gene regulatory processes. Using data from the Illumina 450K array on 336 human peripheral blood samples, we identified 21 CpG sites that associated with age (P<1.03E-7) and exhibited changing rates of DNAm change with age (P<1.94E-6). For 2 of these CpG sites (cg07955995 and cg22285878), DNAm increased with age at an increasing rate, indicating that differential DNAm was greatest among elderly individuals. We observed significant replication for both CpG sites (P<5.0E-8) in a second set of peripheral blood samples. In 8 of 9 additional data sets comprising samples of monocytes, T cell subtypes, and brain tissue, we observed a pattern directionally consistent with DNAm increasing with age at an increasing rate, which was nominally significant in the 3 largest data sets (4.3E-15

  19. Development of a split-flow system for high precision variable sample introduction in supercritical fluid chromatography.

    PubMed

    Sakai, Miho; Hayakawa, Yoshihiro; Funada, Yasuhiro; Ando, Takashi; Fukusaki, Eiichiro; Bamba, Takeshi

    2017-09-15

    In this study, we propose a novel variable sample injection system based on full-loop injection, named the split-flow sample introduction system, for application in supercritical fluid chromatography (SFC). In this system, the mobile phase is split by the differential pressure between two back pressure regulators (BPRs) after full-loop injection suitable for SFC, and this differential pressure determines the introduction rate. Nine compounds with a wide range of characteristics were introduced with high reproducibility and universality, confirming that a robust variable sample injection system was achieved. We also investigated the control factors of our proposed system. Sample introduction was controlled by the ratio between the column-side pressure drops in splitless and split flow, ΔP columnsideinsplitless and ΔP columnsideinsplit , respectively, where ΔP columnsideinsplitless is related to the mobile phase flow rate and composition and the column resistance. When all other conditions are kept constant, increasing the make-up flow induces an additional pressure drop on the column side of the system, which leads to a reduced column-side flow rate, and hence decreased the amount of sample injected, even when the net pressure drop on the column side remains the same. Thus, sample introduction could be highly controlled at low sample introduction rate, regardless of the introduction conditions. This feature is advantageous because, as a control factor, the solvent in the make-up pump is independent of the column-side pressure drop. Copyright © 2017. Published by Elsevier B.V.

  20. Effects of temperature, moisture, and metal salt content on dielectric properties of rice bran associated with radio frequency heating.

    PubMed

    Ling, Bo; Liu, Xiaoli; Zhang, Lihui; Wang, Shaojin

    2018-03-13

    Dielectric heating including microwave (MW) and radio frequency (RF) energy has been regarded as alternative thermal treatments for food processing. To develop effective rice bran (RB) stabilization treatments based on RF and MW heating, dielectric properties (DPs) with dielectric constant (ε') and loss factor (ε″) of RB samples at frequencies (10-3000 MHz), temperatures (25-100 °C), moisture content (MC, 10.36-24.69% w.b.) and three metal salt levels (0.05-2.00%) were determined by an open-ended coaxial probe and impedance analyzer. Results indicated that both ε' and ε″ of RB samples increased with increasing temperature and MC. The increase rate was greater at higher temperature and moisture levels than at lower levels, especially at frequencies lower than 300 MHz. Cubic order models were developed to best fit the relationship between DPs of RB samples and temperature/MC at five frequencies with R 2 greater than 0.994. Both ε″ and RF heating rate of RB samples increased significantly with added NaCl (2%), KCl (1%) and Na 6 O 18 P 6 (2%). The obtained data are useful in developing computer models and simulating dielectric heating for RB stabilization and may also provide theoretical basis for synergistic stabilization of RB under combined dielectric heating with metal salts.

  1. Fat content of the flesh of siscowets and lake trout from Lake Superior

    USGS Publications Warehouse

    Eschmeyer, Paul H.; Phillips, Arthur M.

    1965-01-01

    Samples of flesh were excised from the middorsal region of 67 siscowets (Salvelinus namaycush siscowet) and 46 lake trout (Salvelinus n. namaycush) collected from Lake Superior. Chemical analysis of the samples revealed a range in fat content (dry weight) of 32.5 to 88.8 per cent in siscowets and 6.6 to 52.3 per cent in lake trout. Percentage fat increased progressively with increase in length of fish in both forms, but the average rate of increase was far greater for siscowets than for lake trout at lengths between 12 and 20 inches. Despite substantial individual variation, the percentage fat in the two forms was widely different and without overlap at all comparable lengths. The range in iodine number of the fat was 100 to 160 for siscowets and 103 to 161 for lake trout; average values were generally lower for siscowets than for lake trout among fish of comparable length. Percentage fat and relative weight were not correlated significantly in either subspecies. The fat content of flesh samples from a distinctive subpopulation of Lake Superior lake trout known as 'humpers' was more closely similar to that of typical lean lake trout than to siscowets, but the rate of increase in fat with increasing length was greater than for lean lake trout. Flesh samples from hatchery-reared stocks of lake trout, hybrid lake trout X siscowets, and siscowets tended to support the view that the wide difference in fat content between siscowets and lake trout is genetically determined.

  2. Salivary buffer effect in relation to late pregnancy and postpartum.

    PubMed

    Laine, M; Pienihäkkinen, K

    2000-02-01

    We studied the salivary pH, buffer effect (BE), and flow rates of unstimulated and paraffin-stimulated saliva of 8 women in their late pregnancy and postpartum. Salivary samples were collected about 1 month prior to and about 2 months after delivery. In non-pregnant control women, two paraffin-stimulated salivary samples were collected 1 month apart. The salivary BE increased significantly from late pregnancy to postpartum without exception. The increase was 2.04 +/- 1.17 pH units (P < 0.001) on average. The BE increased from 4.79 +/- 1.64 (final pH) to 6.82 +/- 1.01 (final pH). This change was not due to variation in salivary flow rates, since both unstimulated and paraffin-stimulated flow rates remained unchanged. In control women the difference between the 2 BE measurements was only 0.13 +/- 0.47 pH units on average. We concluded that women with high postpartum BE values may have moderate or even low BE values in late pregnancy. In control women, individual variation was found to be low in all variables studied.

  3. Towards TiO2 nanotubes modified by WO3 species: influence of ex situ crystallization of precursor on the photocatalytic activities of WO3/TiO2 composites

    NASA Astrophysics Data System (ADS)

    Sun, Hui; Dong, Bohua; Su, Ge; Gao, Rongjie; Liu, Wei; Song, Liang; Cao, Lixin

    2015-09-01

    TiO2 nanotubes (TNT) crystallized at different temperatures were loaded with WO3 hydrate through the reaction between (NH4)6W7O24·6H2O and an aqueous solution of HCl. The photocatalytic activities of nanocomposites firstly increase and then decrease as a function of the crystallized temperature of the TNT precursor. The structural, morphologic and optical properties of WO3/TiO2 nanocomposites were also investigated in this study. The samples, initially anatase titania (573 K-773 K), presented phase transition to rutile titania at 873 K. With the crystallized temperature increasing, an evolution of samples morphology changing from nanotube-like structure to nanorod-like structure was observed. Meanwhile, the absorption edge of samples exhibited a red shift, and correspondingly their band gap decreased. Consistent with x-ray diffraction diffractograms, the existence of rutile titania as an impurity in the precursor TNT, crystallized at higher than 873 K, depressed photocatalytic activity evidently. As a result, the degradation rate of methyl orange (MO) increased with the samples crystallinity firstly, and then reduced due to the appearance of rutile titania. In our experimental conditions, the optimal photocatalytic activity was achieved for the sample crystalized at 773 K. Its degradation rate could reach 98.76% after 90 min UV light irradiation.

  4. Keeping Pace With Water and Wastewater Rates

    DOE PAGES

    Stratton, Hannah; Fuchs, Heidi; Chen, Yuting; ...

    2017-10-01

    We present that water and wastewater treatment and delivery are the most capital-intensive of all utility services. The literature indicates that historically underpriced water and wastewater rates have exhibited steadily high growth in the past 15 years, while the consumer price index (CPI) of water and sewage maintenance has outpaced the general CPI by an increasingly wide margin. This article employs a chained analysis method to examine water and wastewater rates for a group of utilities across US Census regions between 2000 and 2014. Results demonstrate that water and wastewater prices for this sample group have consistently increased and havemore » surpassed CPI growth since 2006. Finally, current and upcoming challenges facing water and wastewater utilities suggest that rate increases are likely to continue in the foreseeable future.« less

  5. Keeping Pace With Water and Wastewater Rates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stratton, Hannah; Fuchs, Heidi; Chen, Yuting

    We present that water and wastewater treatment and delivery are the most capital-intensive of all utility services. The literature indicates that historically underpriced water and wastewater rates have exhibited steadily high growth in the past 15 years, while the consumer price index (CPI) of water and sewage maintenance has outpaced the general CPI by an increasingly wide margin. This article employs a chained analysis method to examine water and wastewater rates for a group of utilities across US Census regions between 2000 and 2014. Results demonstrate that water and wastewater prices for this sample group have consistently increased and havemore » surpassed CPI growth since 2006. Finally, current and upcoming challenges facing water and wastewater utilities suggest that rate increases are likely to continue in the foreseeable future.« less

  6. Influence of Heart Rate in Non-linear HRV Indices as a Sampling Rate Effect Evaluated on Supine and Standing.

    PubMed

    Bolea, Juan; Pueyo, Esther; Orini, Michele; Bailón, Raquel

    2016-01-01

    The purpose of this study is to characterize and attenuate the influence of mean heart rate (HR) on nonlinear heart rate variability (HRV) indices (correlation dimension, sample, and approximate entropy) as a consequence of being the HR the intrinsic sampling rate of HRV signal. This influence can notably alter nonlinear HRV indices and lead to biased information regarding autonomic nervous system (ANS) modulation. First, a simulation study was carried out to characterize the dependence of nonlinear HRV indices on HR assuming similar ANS modulation. Second, two HR-correction approaches were proposed: one based on regression formulas and another one based on interpolating RR time series. Finally, standard and HR-corrected HRV indices were studied in a body position change database. The simulation study showed the HR-dependence of non-linear indices as a sampling rate effect, as well as the ability of the proposed HR-corrections to attenuate mean HR influence. Analysis in a body position changes database shows that correlation dimension was reduced around 21% in median values in standing with respect to supine position ( p < 0.05), concomitant with a 28% increase in mean HR ( p < 0.05). After HR-correction, correlation dimension decreased around 18% in standing with respect to supine position, being the decrease still significant. Sample and approximate entropy showed similar trends. HR-corrected nonlinear HRV indices could represent an improvement in their applicability as markers of ANS modulation when mean HR changes.

  7. Study design and sampling intensity for demographic analyses of bear populations

    USGS Publications Warehouse

    Harris, R.B.; Schwartz, C.C.; Mace, R.D.; Haroldson, M.A.

    2011-01-01

    The rate of population change through time (??) is a fundamental element of a wildlife population's conservation status, yet estimating it with acceptable precision for bears is difficult. For studies that follow known (usually marked) bears, ?? can be estimated during some defined time by applying either life-table or matrix projection methods to estimates of individual vital rates. Usually however, confidence intervals surrounding the estimate are broader than one would like. Using an estimator suggested by Doak et al. (2005), we explored the precision to be expected in ?? from demographic analyses of typical grizzly (Ursus arctos) and American black (U. americanus) bear data sets. We also evaluated some trade-offs among vital rates in sampling strategies. Confidence intervals around ?? were more sensitive to adding to the duration of a short (e.g., 3 yrs) than a long (e.g., 10 yrs) study, and more sensitive to adding additional bears to studies with small (e.g., 10 adult females/yr) than large (e.g., 30 adult females/yr) sample sizes. Confidence intervals of ?? projected using process-only variance of vital rates were only slightly smaller than those projected using total variances of vital rates. Under sampling constraints typical of most bear studies, it may be more efficient to invest additional resources into monitoring recruitment and juvenile survival rates of females already a part of the study, than to simply increase the sample size of study females. ?? 2011 International Association for Bear Research and Management.

  8. A compact, fast ozone UV photometer and sampling inlet for research aircraft

    NASA Astrophysics Data System (ADS)

    Gao, R. S.; Ballard, J.; Watts, L. A.; Thornberry, T. D.; Ciciora, S. J.; McLaughlin, R. J.; Fahey, D. W.

    2012-05-01

    In situ measurements of atmospheric ozone (O3) are performed routinely from many research aircraft platforms. The most common technique depends on the strong absorption of ultraviolet (UV) light by ozone. As atmospheric science advances to the widespread use of unmanned aircraft systems (UASs), there is an increasing requirement for minimizing instrument space, weight, and power while maintaining instrument accuracy, precision and time response. The design and use of a new, dual-beam, polarized, UV photometer instrument for in situ O3 measurements is described. The instrument has a fast sampling rate (2 Hz), high accuracy (3%), and precision (1.1 × 1010 O3 molecules cm-3). The size (36 l), weight (18 kg), and power (50-200 W) make the instrument suitable for many UAS and other airborne platforms. Inlet and exhaust configurations are also described for ambient sampling in the troposphere and lower stratosphere (1000-50 mb) that optimize the sample flow rate to increase time response while minimizing loss of precision due to induced turbulence in the sample cell. In-flight and laboratory intercomparisons with existing O3 instruments show that measurement accuracy is maintained in flight.

  9. Estimates of Marine Debris Accumulation on Beaches Are Strongly Affected by the Temporal Scale of Sampling

    PubMed Central

    Smith, Stephen D. A.; Markic, Ana

    2013-01-01

    Marine debris is a global issue with impacts on marine organisms, ecological processes, aesthetics and economies. Consequently, there is increasing interest in quantifying the scale of the problem. Accumulation rates of debris on beaches have been advocated as a useful proxy for at-sea debris loads. However, here we show that past studies may have vastly underestimated the quantity of available debris because sampling was too infrequent. Our study of debris on a small beach in eastern Australia indicates that estimated daily accumulation rates decrease rapidly with increasing intervals between surveys, and the quantity of available debris is underestimated by 50% after only 3 days and by an order of magnitude after 1 month. As few past studies report sampling frequencies of less than a month, estimates of the scale of the marine debris problem need to be critically re-examined and scaled-up accordingly. These results reinforce similar, recent work advocating daily sampling as a standard approach for accurate quantification of available debris in coastal habitats. We outline an alternative approach whereby site-specific accumulation models are generated to correct bias when daily sampling is impractical. PMID:24367607

  10. Investigation of acrylamide formation on bakery products using a crust-like model.

    PubMed

    Açar, Ozge C; Gökmen, Vural

    2009-12-01

    Baking is a complex process where a temperature gradient occurs within the product as a result of simultaneous heat and mass transfers. This behaviour makes the physical parameters (baking temperature and product dimensions) as effective as the chemical parameters on the rate of acrylamide formation in bakery foods. In this study, the change of temperature in different locations of the sample was shown as influenced by the product thickness. The temperature values were close to each other in the sample having thickness of 1 mm (crust model). The product temperature rapidly increased to the oven temperature. A temperature gradient was recorded in the sample having a thickness of 10 mm. As a result, the product temperature did not exceed 100 degrees C within a baking time of 30 min. The product thickness significantly influenced the rate of acrylamide formation during baking. Acrylamide concentration rapidly increased to 411+/-49 ng/g within 8 min in the crust model sample. However, no acrylamide was detected in the thicker sample within 15 min under the same conditions, because the moisture content was still above 10%. The crust model was considered useful to test the effectiveness of different mitigation strategies in bakery foods.

  11. Gas, Oil, and Water Production from Jonah, Pinedale, Greater Wamsutter, and Stagecoach Draw Fields in the Greater Green River Basin, Wyoming

    USGS Publications Warehouse

    Nelson, Philip H.; Ewald, Shauna M.; Santus, Stephen L.; Trainor, Patrick K.

    2010-01-01

    Gas, oil, and water production data were compiled from selected wells in four gas fields in rocks of Late Cretaceous age in southwestern Wyoming. This study is one of a series of reports examining fluid production from tight-gas reservoirs, which are characterized by low permeability, low porosity, and the presence of clay minerals in pore space. Production from each well is represented by two samples spaced five years apart, the first sample typically taken two years after commencement of production. For each producing interval, summary diagrams of oil versus gas and water versus gas production show fluid production rates, the change in rates during five years, the water-gas and oil-gas ratios, and the fluid type. These diagrams permit well-to-well and field-to-field comparisons. Fields producing water at low rates (water dissolved in gas in the reservoir) can be distinguished from fields producing water at moderate or high rates, and the water-gas ratios are quantified. The ranges of first-sample gas rates in Pinedale field and Jonah field are quite similar, and the average gas production rate for the second sample, taken five years later, is about one-half that of the first sample for both fields. Water rates are generally substantially higher in Pinedale than in Jonah, and water-gas ratios in Pinedale are roughly a factor of ten greater in Pinedale than in Jonah. Gas and water production rates from each field are fairly well grouped, indicating that Pinedale and Jonah fields are fairly cohesive gas-water systems. Pinedale field appears to be remarkably uniform in its flow behavior with time. Jonah field, which is internally faulted, exhibits a small spread in first-sample production rates. In the Greater Wamsutter field, gas production from the upper part of the Almond Formation is greater than from the main part of the Almond. Some wells in the main and the combined (upper and main parts) Almond show increases in water production with time, whereas increases in water production are rare in the upper part of the Almond, and a higher percentage of wells in the upper part of the Almond show water decreasing at the same rate as gas than in the main or combined parts of the Almond. In Stagecoach Draw field, the gas production rate after five years is about one-fourth that of the first sample, whereas in Pinedale, Jonah, and Greater Wamsutter fields, the production rate after five years is about one-half that of the first sample. The more rapid gas decline rate seems to be the outstanding feature distinguishing Stagecoach Draw field, which is characterized as a conventional field, from Pinedale, Jonah, and Greater Wamsutter fields, which are generally characterized as tight-gas accumulations. Oil-gas ratios are fairly consistent within Jonah, Pinedale, and Stagecoach Draw fields, suggesting similar chemical composition and pressure-temperature conditions within each field, and are less than the 20 bbl/mmcf upper limit for wet gas. However, oil-gas ratios vary considerably from one area to another in the Greater Wamsutter field, demonstrating a lack of commonality in either chemistry or pressure-temperature conditions among the six areas. In all wells in all four fields examined here, water production commences with gas production-there are no examples of wells with water-free production and no examples where water production commences after first-sample gas production. The fraction of records with water production higher in the second sample than in the first sample varies from field to field, with Pinedale field showing the lowest percentage of such cases and Jonah field showing the most. Most wells have water-gas ratios exceeding the amount that could exist dissolved in gas at reservoir pressure and temperature.

  12. Disabilities and Degrees: Identifying Health Impairments That Predict Lower Chances of College Enrollment and Graduation in a Nationally Representative Sample

    ERIC Educational Resources Information Center

    Rosenbaum, Janet E.

    2018-01-01

    Objective: Colleges have increased postsecondary educational access for youth, including individuals with disabilities, but completion rates remain low. This study tests the hypothesis that health conditions that reduce social integration predict lower educational attainment among college students. Method: The sample from the nationally…

  13. P-Type Factor Analyses of Individuals' Thought Sampling Data.

    ERIC Educational Resources Information Center

    Hurlburt, Russell T.; Melancon, Susan M.

    Recently, interest in research measuring stream of consciousness or thought has increased. A study was conducted, based on a previous study by Hurlburt, Lech, and Saltman, in which subjects were randomly interrupted to rate their thoughts and moods on a Likert-type scale. Thought samples were collected from 27 subjects who carried random-tone…

  14. CFO compensation method using optical feedback path for coherent optical OFDM system

    NASA Astrophysics Data System (ADS)

    Moon, Sang-Rok; Hwang, In-Ki; Kang, Hun-Sik; Chang, Sun Hyok; Lee, Seung-Woo; Lee, Joon Ki

    2017-07-01

    We investigate feasibility of carrier frequency offset (CFO) compensation method using optical feedback path for coherent optical orthogonal frequency division multiplexing (CO-OFDM) system. Recently proposed CFO compensation algorithms provide wide CFO estimation range in electrical domain. However, their practical compensation range is limited by sampling rate of an analog-to-digital converter (ADC). This limitation has not drawn attention, since the ADC sampling rate was high enough comparing to the data bandwidth and CFO in the wireless OFDM system. For CO-OFDM, the limitation is becoming visible because of increased data bandwidth, laser instability (i.e. large CFO) and insufficient ADC sampling rate owing to high cost. To solve the problem and extend practical CFO compensation range, we propose a CFO compensation method having optical feedback path. By adding simple wavelength control for local oscillator, the practical CFO compensation range can be extended to the sampling frequency range. The feasibility of the proposed method is experimentally investigated.

  15. Design and performance of tapered cubic anvil used for achieving higher pressure and larger sample cell

    NASA Astrophysics Data System (ADS)

    Han, Qi-Gang; Yang, Wen-Ke; Zhu, Pin-Wen; Ban, Qing-Chu; Yan, Ni; Zhang, Qiang

    2013-07-01

    In order to increase the maximum cell pressure of the cubic high pressure apparatus, we have developed a new structure of tungsten carbide cubic anvil (tapered cubic anvil), based on the principle of massive support and lateral support. Our results indicated that the tapered cubic anvil has some advantages. First, tapered cubic anvil can push the transfer rate of pressure well into the range above 36.37% compare to the conventional anvil. Second, the rate of failure crack decreases about 11.20% after the modification of the conventional anvil. Third, the limit of static high-pressure in the sample cell can be extended to 13 GPa, which can increase the maximum cell pressure about 73.3% than that of the conventional anvil. Fourth, the volume of sample cell compressed by tapered cubic anvils can be achieved to 14.13 mm3 (3 mm diameter × 2 mm long), which is three and six orders of magnitude larger than that of double-stage apparatus and diamond anvil cell, respectively. This work represents a relatively simple method for achieving higher pressures and larger sample cell.

  16. Mg Incorporation Efficiency in Pulsed MOCVD of N-Polar GaN:Mg

    NASA Astrophysics Data System (ADS)

    Marini, Jonathan; Mahaboob, Isra; Hogan, Kasey; Novak, Steve; Bell, L. D.; Shahedipour-Sandvik, F.

    2017-10-01

    We report on the effect of growth polarity and pulsed or δ -doped growth mode on impurity incorporation in metalorganic chemical vapor deposition-grown GaN. In Ga-polar orientation, up to 12× enhancement in Mg concentration for given Mg flow rate is observed, resulting in enhanced p-type conductivity for these samples. In contrast, this enhancement effect is greatly diminished for N-polar samples, falling off with increasing Mg flow and showing maximum enhancement of 2.7× at 30 nmol/min Mg flow. At higher Mg flow rates, Mg incorporation at normal levels did not correspond to p-type conductivity, which may be due to Mg incorporation at nonacceptor sites. Concentrations of C, O, and Si were also investigated, revealing dependence on Mg flow in N-polar pulsed samples. Carbon incorporation was found to decrease with increasing Mg flow, and oxygen incorporation was found to remain high across varied Mg flow. These effects combine to result in N-polar samples that are not p-type when using the pulsed growth mode.

  17. Effect of Longitudinal Oscillations on Downward Flame Spread over Thin Solid Fuels

    NASA Technical Reports Server (NTRS)

    Nayagam, Vedha; Sacksteder, Kurt

    2013-01-01

    Downward flame spread rates over vertically vibrated thin fuel samples are measured in air at one atmospheric pressure under normal gravity. Unlike flame spread against forced-convective flows, the present results show that with increasing vibration acceleration the flame spread rate increases before being blown off at high acceleration levels causing flame extinction. A simple scaling analysis seems to explain this phenomenon, which may have important implications to flammability studies including in microgravity environments.

  18. Mercury photoreduction and photooxidation in lakes: Effects of filtration and dissolved organic carbon concentration.

    PubMed

    O'Driscoll, Nelson J; Vost, Emma; Mann, Erin; Klapstein, Sara; Tordon, Robert; Lukeman, Matthew

    2018-06-01

    Mercury is a globally distributed, environmental contaminant. Quantifying the retention and loss of mercury is integral for predicting mercury-sensitive ecosystems. There is little information on how dissolved organic carbon (DOC) concentrations and particulates affect mercury photoreaction kinetics in freshwater lakes. To address this knowledge gap, samples were collected from ten lakes in Kejimkujik National Park, Nova Scotia (DOC: 2.6-15.4mg/L). Filtered (0.2μm) and unfiltered samples were analysed for gross photoreduction, gross photooxidation, and net reduction rates of mercury using pseudo first-order curves. Unfiltered samples had higher concentrations (p=0.04) of photoreducible divalent mercury (Hg(II) RED ) (mean of 754±253pg/L) than filtered samples (mean of 482±206pg/L); however, gross photoreduction and photooxidation rate constants were not significantly different in filtered or unfiltered samples in early summer. DOC was not significantly related to gross photoreduction rate constants in filtered (R 2 =0.43; p=0.08) and unfiltered (R 2 =0.02; p=0.71) samples; DOC was also not significantly related to gross photooxidation rate constants in filtered or unfiltered samples. However, DOC was significantly negatively related with Hg(II) RED in unfiltered (R 2 =0.53; p=0.04), but not in filtered samples (R 2 =0.04; p=0.60). These trends indicate that DOC is a factor in determining dissolved mercury photoreduction rates and particles partially control available Hg(II) RED in lake water. This research also demonstrates that within these lakes gross photoreduction and photooxidation processes are close to being in balance. Changes to catchment inputs of particulate matter and DOC may alter mercury retention in these lakes and could partially explain observed increases of mercury accumulation in biota. Copyright © 2017. Published by Elsevier B.V.

  19. Cooling rates for glass containing lunar compositions

    NASA Technical Reports Server (NTRS)

    Fang, C. Y.; Yinnon, H.; Uhlmann, D. R.

    1983-01-01

    Cooling rates required to form glassy or partly-crystalline bodies of 14 lunar compositions have been estimated using a previously introduced, simplified model. The calculated cooling rates are found to be in good agreement with cooling rates measured for the same compositions. Measurements are also reported of the liquidus temperature and glass transition temperature for each composition. Inferred cooling rates are combined with heat flow analyses to obtain insight into the thermal histories of samples 15422, 14162, 15025, 74220, 74241, 10084, 15425, and 15427. The critical cooling rates required to form glasses of 24 lunar compositions, including the 14 compositions of the present study, are suggested to increase systematically with increasing ratio of total network modifiers/total network formers in the compositions. This reflects the importance of melt viscosity in affecting glass formation.

  20. Microstructural Evaluation of Forging Parameters for Superalloy Disks

    NASA Technical Reports Server (NTRS)

    Falsey, John R.

    2004-01-01

    Forgings of nickel base superalloy were formed under several different strain rates and forging temperatures. Samples were taken from each forging condition to find the ASTM grain size, and the as large as grain (ALA). The specimens were mounted in bakelite, polished, etched and then optical microscopy was used to determine grain size. The specimens ASTM grain sizes from each forging condition were plotted against strain rate, forging temperature, and presoak time. Grain sizes increased with increasing forging temperature. Grain sizes also increased with decreasing strain rates and increasing forging presoak time. The ALA had been determined from each forging condition using the ASTM standard method. Each ALA was compared with the ASTM grain size of each forging condition to determine if the grain sizes were uniform or not. The forging condition of a strain rate of .03/sec and supersolvus heat treatment produced non uniform grains indicated by critical grain growth. Other anomalies are noted as well.

  1. An investigation on polycyclic aromatic hydrocarbon emissions from pulverized coal combustion systems

    PubMed

    Pisupati; Wasco; Scaroni

    2000-05-29

    Results from a series of tests conducted to study the emission of polynuclear or polycyclic aromatic hydrocarbons (PAHs) from bench-scale and small industrial, water-tube boiler are discussed. A Middle Kittanning, and Upper Freeport seam coals were used in the study. Samples were extracted from the reactor outlet and from the inlet and outlet sides of the research boiler's (RB) baghouse using EPA promulgated methods.Only acenaphthene and fluoranthene were detected in down-fired combustor (DFC) samples. In addition to these two, naphthalene was detected in the RB samples. Emission factors ranged from 80 to 320 &mgr;g/kg of fuel fired. Although there were minor trends in the emissions' data, given the reproducibility limits for PAH compounds, no significant differences were found in the emissions with respect to the fuel type or form (pulverized coal (PC) vs. coal-water slurry fuel (CWSF), and raw vs. cleaned coal) and firing conditions (high and low excess air). The PAH emissions showed a decrease with increase in the firing rate.A bench-scale drop-tube reactor (DTR) was used to study the effects of temperature and residence time on PAH formation. The results revealed near constant PAH concentrations in the solid-phase samples, while the PAH concentrations in the vapor-phase samples increased as a function of temperature. At a temperature of around 1300 degrees C, the rate of PAH formation was exceeded by the rate of PAH oxidation, and PAH concentrations in the vapor phase began to decrease.

  2. Methylation of Werner syndrome protein is associated with the occurrence and development of invasive meningioma via the regulation of Myc and p53 expression.

    PubMed

    Li, Puxian; Hao, Shuyu; Bi, Zhiyong; Zhang, Junting; Wu, Zhen; Ren, Xiaohui

    2015-08-01

    The aim of the present study was to investigate the positive rate of Werner syndrome protein (WRN) methylation in meningioma patients, and further assess the association between WRN methylation and the occurrence of meningioma. A total of 56 consecutive meningioma patients and 26 healthy individuals were enrolled in the study. A methylation-specific polymerase chain reaction assay was performed to detect the positive rate of WRN methylation in the peripheral blood and tissue samples collected from the recruited subjects. In addition, western blot analysis was performed to determine the protein expression levels of WRN, Myc and p53 in the peripheral blood and tissue samples. The positive rate of WRN methylation in the peripheral blood of the meningioma group was increased when compared with the control group (P<0.05). In addition, the protein expression levels of WRN were significantly decreased in the peripheral blood and tissue samples collected from the individuals with a positive WRN methylation status (P<0.05), as compared with the samples without WRN methylation. Furthermore, the protein expression levels of Myc and p53 were increased in the peripheral blood and tissue samples that exhibited positive WRN methylation when compared with those without WRN methylation (P<0.05). Therefore, WRN methylation was demonstrated to be associated with the occurrence and development of invasive meningioma, possibly through the regulation of Myc and p53 expression.

  3. Magnetic hyperthermia study in water based magnetic fluids containing TMAOH coated Fe3O4 using infrared thermography

    NASA Astrophysics Data System (ADS)

    Lahiri, B. B.; Ranoo, Surojit; Philip, John

    2017-01-01

    We study the alternating magnetic field induced heating of a water based ferrofluid containing tetramethyl ammonium hydroxide coated iron oxide nanoparticles using infrared thermography and compare the results obtained from the conventional fiber optic temperature sensor. Experiments are performed on ferrofluid samples of five different concentrations and under four different external field amplitudes at a fixed frequency. The temperature rise curves measured using both the infrared thermography and fiber optic sensor are found to be very similar up to a certain time interval, above which deviations are observed, which are attributed to the internal and external convection phenomena. A correction methodology is developed to account for the convection losses. The convection corrected specific absorption rate is found to be in good agreement with the values obtained from the conventional fiber optic temperature sensor, within a maximum error of ±3.4%. The highest specific absorption rate obtained in the present study is 135.98 (±4.6) W/gFe for a sample concentration of 3 wt.%, at an external field amplitude and a frequency of 63.0 kA m-1 and 126 kHz, respectively. The specific absorption rate is found to decrease with increasing sample concentration, due to the enhancement of dipolar interaction with increasing sample concentration due to agglomeration. This study validates the efficacy and universal applicability of IRT as an alternate, real time, non-contact and wide area temperature measurement methodology for magnetic fluid hyperthermia experiments without any sample contamination.

  4. Inhibition of Sodium Benzoate on Stainless Steel in Tropical Seawater

    NASA Astrophysics Data System (ADS)

    Seoh, S. Y.; Senin, H. B.; Nik, W. N. Wan; Amin, M. M.

    2007-05-01

    The inhibition of sodium benzoate for stainless steel controlling corrosion was studied in seawater at room temperature. Three sets of sample have been immersed in seawater containing sodium benzoate with the concentrations of 0.3M, 0.6M and 1.0M respectively. One set of sample has been immersed in seawater without adding any sodium benzoate. It was found that the highest corrosion rate was observed for the stainless steel with no inhibitor was added to the seawater. As the concentration of sodium benzoate being increased, the corrosion rate is decreases. Results show that by the addition of 1.0M of sodium benzoate in seawater samples, it giving ≥ 90% efficiencies.

  5. Comparison of prevalence estimation of Mycobacterium avium subsp. paratuberculosis infection by sampling slaughtered cattle with macroscopic lesions vs. systematic sampling.

    PubMed

    Elze, J; Liebler-Tenorio, E; Ziller, M; Köhler, H

    2013-07-01

    The objective of this study was to identify the most reliable approach for prevalence estimation of Mycobacterium avium ssp. paratuberculosis (MAP) infection in clinically healthy slaughtered cattle. Sampling of macroscopically suspect tissue was compared to systematic sampling. Specimens of ileum, jejunum, mesenteric and caecal lymph nodes were examined for MAP infection using bacterial microscopy, culture, histopathology and immunohistochemistry. MAP was found most frequently in caecal lymph nodes, but sampling more tissues optimized the detection rate. Examination by culture was most efficient while combination with histopathology increased the detection rate slightly. MAP was detected in 49/50 animals with macroscopic lesions representing 1.35% of the slaughtered cattle examined. Of 150 systematically sampled macroscopically non-suspect cows, 28.7% were infected with MAP. This indicates that the majority of MAP-positive cattle are slaughtered without evidence of macroscopic lesions and before clinical signs occur. For reliable prevalence estimation of MAP infection in slaughtered cattle, systematic random sampling is essential.

  6. Alcohol Use, Age, and Self-Rated Mental and Physical Health in a Community Sample of Lesbian and Bisexual Women.

    PubMed

    Veldhuis, Cindy B; Talley, Amelia E; Hancock, David W; Wilsnack, Sharon C; Hughes, Tonda L

    2017-12-01

    Given that self-perceptions of mental and physical health are important predictors of health outcomes and well-being, particularly among older adults, this study focuses on associations among age, alcohol consumption, and indicators of both self-rated mental health and self-rated physical health in a sample of sexual minority women (SMW). This study uses a community sample of SMW to examine the associations among age, drinking, and self-rated mental and physical health. Heavy drinking among older adult SMW (55+) was less prevalent than among young SMW, ages 18-25 and ages 26-39, but similar to rates reported among SMW ages 40-54. In addition, older SMW reported significantly higher levels of self-rated mental health, compared with SMW in the other age groups, but we found no significant associations between age and self-rated physical health. Across all age groups, moderate drinkers reported better self-rated physical health than alcohol abstainers. Overall, these results suggest that, among SMW, drinking does not decline as sharply with age as it does for heterosexual women in the general population. Given the current and projected increases in the aging population and the risks that heavy drinking presents for morbidity and mortality, interventions aimed at older SMW are needed.

  7. Structural and magnetic characterization of Ti doped cobalt ferrite (CoFe2O4)

    NASA Astrophysics Data System (ADS)

    Pal, Jaswinder; Kumar, Sunil; Kaur, Randeep; Agrawal, P.; Singh, Mandeep; Singh, Anupinder

    2018-05-01

    Synthesis of Co1-xTixFe2O4 solid solutions for 0.1≤x≤0.4 using the solid-state-reaction rate has been done. The prepared samples were characterized by using XRD (X-ray diffraction) and SEM (Scanning Electron Microscopy). Magnetic studies have been done using Vibrating Sample Magnetometer (VSM). XRD confirmed that Cobalt Ferrite spinel cubic structure in all prepared samples. The lattice parameter `a' increases with increase in the concentration of Ti. SEM micrograph shows good grain growth in all samples. Magnetic Study reveals that the M-H curves of all the prepared samples taken at room temperature are very well saturated. The maximum value of remnant magnetization (Mr ˜13.9 emu/g) and saturation magnetization (Ms ˜74.4 emu/g) has been observed for x =0.2 sample. Coercivity does not show any regular variation with increase in the molar concentration of Ti in CoFe2O4 at A-site.

  8. Remarkably Enhanced Room-Temperature Hydrogen Sensing of SnO₂ Nanoflowers via Vacuum Annealing Treatment.

    PubMed

    Liu, Gao; Wang, Zhao; Chen, Zihui; Yang, Shulin; Fu, Xingxing; Huang, Rui; Li, Xiaokang; Xiong, Juan; Hu, Yongming; Gu, Haoshuang

    2018-03-23

    In this work, SnO₂ nanoflowers synthesized by a hydrothermal method were employed as hydrogen sensing materials. The as-synthesized SnO₂ nanoflowers consisted of cuboid-like SnO₂ nanorods with tetragonal structures. A great increase in the relative content of surface-adsorbed oxygen was observed after the vacuum annealing treatment, and this increase could have been due to the increase in surface oxygen vacancies serving as preferential adsorption sites for oxygen species. Annealing treatment resulted in an 8% increase in the specific surface area of the samples. Moreover, the conductivity of the sensors decreased after the annealing treatment, which should be attributed to the increase in electron scattering around the defects and the compensated donor behavior of the oxygen vacancies due to the surface oxygen adsorption. The hydrogen sensors of the annealed samples, compared to those of the unannealed samples, exhibited a much higher sensitivity and faster response rate. The sensor response factor and response rate increased from 27.1% to 80.2% and 0.34%/s to 1.15%/s, respectively. This remarkable enhancement in sensing performance induced by the annealing treatment could be attributed to the larger specific surface areas and higher amount of surface-adsorbed oxygen, which provides a greater reaction space for hydrogen. Moreover, the sensors with annealed SnO₂ nanoflowers also exhibited high selectivity towards hydrogen against CH₄, CO, and ethanol.

  9. Variation in chlorotoluron photodegradation rates as a result of seasonal changes in the composition of natural waters.

    PubMed

    Oliver, Robin G; Wallace, Derek F; Earll, Mark

    2013-01-01

    It is important to understand the degradation of organic molecules in surface waters to ensure that risk assessments, intended to prevent adverse effects on human health and the environment, are robust. One important degradation mechanism in surface waters is photodegradation. This process is generally studied in laboratory test systems, and the significance of the results is then extrapolated to the field. The aim of this work was to assess how fluctuations in the composition of surface water influence the photodegradation rate of chlorotoluron. Photodegradation DT(50) values in the lake (mean = 26.0 days) and pond (mean = 26.0 days) were significantly slower than in the river (mean = 6.8 days) and stream (mean = 7.3 days) samples. The DT(50) values in the pond and lake samples were similar to the direct photolysis value (mean = 28.6 days). Photodegradation was significantly faster in the stream and river samples, suggesting that indirect photolysis was significant in those waters. Principal component analysis indicated a strong inverse correlation between nitrate concentration and degradation rate. Nitrate concentration had a strong influence on the rate of photodegradation, with increasing nitrate concentrations sharply reducing the DT(50) . However, this effect was restricted to a narrow concentration range and levelled off quite quickly, such that further increases in the nitrate concentration had no significant effect on the rate of degradation. Extrapolating photodegradation rates of chlorotoluron from the laboratory to the field should be relatively straightforward, provided the nitrate concentrations in the waters are known. Copyright © 2012 Society of Chemical Industry.

  10. Effect of Frequency and Waveform on Inactivation of Escherichia coli O157:H7 and Salmonella enterica Serovar Typhimurium in Salsa by Ohmic Heating

    PubMed Central

    Lee, Su-Yeon; Ryu, Sangryeol

    2013-01-01

    The effect of frequency of alternating current during ohmic heating on electrode corrosion, heating rate, inactivation of food-borne pathogens, and quality of salsa was investigated. The impact of waveform on heating rate was also investigated. Salsa was treated with various frequencies (60 Hz to 20 kHz) and waveforms (sine, square, and sawtooth) at a constant electric field strength of 12.5 V/cm. Electrode corrosion did not occur when the frequency exceeded 1 kHz. The heating rate of the sample was dependent on frequency up to 500 Hz, but there was no significant difference (P > 0.05) in the heating rate when the frequency was increased above 1 kHz. The electrical conductivity of the sample increased with a rise in the frequency. At a frequency of 60 Hz, the square wave produced a lower heating rate than that of sine and sawtooth waves. The heating rate between waveforms was not significantly (P > 0.05) different when the frequency was >500 Hz. As the frequency increased, the treatment time required to reduce Escherichia coli O157:H7 and Salmonella enterica serovar Typhimurium to below the detection limit (1 log CFU/g) decreased without affecting product quality. These results suggest that ohmic heating can be effectively used to pasteurize salsa and that the effect of inactivation is dependent on frequency and electrical conductivity rather than waveform. PMID:23023752

  11. Effect of frequency and waveform on inactivation of Escherichia coli O157:H7 and Salmonella enterica Serovar Typhimurium in salsa by ohmic heating.

    PubMed

    Lee, Su-Yeon; Ryu, Sangryeol; Kang, Dong-Hyun

    2013-01-01

    The effect of frequency of alternating current during ohmic heating on electrode corrosion, heating rate, inactivation of food-borne pathogens, and quality of salsa was investigated. The impact of waveform on heating rate was also investigated. Salsa was treated with various frequencies (60 Hz to 20 kHz) and waveforms (sine, square, and sawtooth) at a constant electric field strength of 12.5 V/cm. Electrode corrosion did not occur when the frequency exceeded 1 kHz. The heating rate of the sample was dependent on frequency up to 500 Hz, but there was no significant difference (P > 0.05) in the heating rate when the frequency was increased above 1 kHz. The electrical conductivity of the sample increased with a rise in the frequency. At a frequency of 60 Hz, the square wave produced a lower heating rate than that of sine and sawtooth waves. The heating rate between waveforms was not significantly (P > 0.05) different when the frequency was >500 Hz. As the frequency increased, the treatment time required to reduce Escherichia coli O157:H7 and Salmonella enterica serovar Typhimurium to below the detection limit (1 log CFU/g) decreased without affecting product quality. These results suggest that ohmic heating can be effectively used to pasteurize salsa and that the effect of inactivation is dependent on frequency and electrical conductivity rather than waveform.

  12. Effect of storage conditions on the calorific value of municipal solid waste.

    PubMed

    Nzioka, Antony Mutua; Hwang, Hyeon-Uk; Kim, Myung-Gyun; Yan, Cao Zheng; Lee, Chang-Soo; Kim, Young-Ju

    2017-08-01

    Storage conditions are considered to be an important factor as far as waste material characteristics are concerned. This experimental investigation was conducted using municipal solid waste (MSW) with a high moisture content and varying composition of organic waste. The objective of this study was to understand the effect of storage conditions and temperature on the moisture content and calorific value of the waste. Samples were subjected to two different storage conditions and investigated at specified temperatures. The composition of sample materials investigated was varied for each storage condition and temperature respectively. Gross calorific value was determined experimentally while net calorific value was calculated using empirical formulas proposed by other researchers. Results showed minimal changes in moisture content as well as in gross and net calorific values when the samples were subjected to sealed storage conditions. Moisture content reduced due to the ventilation process and the rate of moisture removal increased with a rise in storage temperature. As expected, rate of moisture removal had a positive effect on gross and net calorific values. Net calorific values also increased at varying rates with a simultaneous decrease in moisture content. Experimental investigation showed the effectiveness of ventilation in improving the combustion characteristics of the waste.

  13. Protein synthesis rates in atrophied gastrocnemius muscles after limb immobilization

    NASA Technical Reports Server (NTRS)

    Tucker, K. R.; Seider, M. J.; Booth, F. W.

    1981-01-01

    Noting that protein synthesis declines in the gastrocnemius 6 hr after immobilization, the study sought to detect an increase of protein synthesis when the limb was freed, and to examine the effects of exercise on the rate of increase. Rats were used as subjects, with their hind legs in plaster of Paris in plantar flexion to eliminate strain on the gastrocnemius. Periods of immobilization were varied and samples of blood from the muscle were taken to track protein synthesis rates for different groups in immobilization and exercise regimens (running and weightlifting). Synthesis rates declined 3.6% during time in the cast, then increased 6.3%/day after the casts were removed. Both running and weightlifting were found to increase the fractional rate of protein formation in the gastrocnemius muscle when compared with contralateral muscles that were not exercised and were used as controls, suggesting that the mechanism controlling protein synthesis in skeletal muscles is rapidly responsive to changes in muscular contractile activity.

  14. The impact of multiple endpoint dependency on Q and I(2) in meta-analysis.

    PubMed

    Thompson, Christopher Glen; Becker, Betsy Jane

    2014-09-01

    A common assumption in meta-analysis is that effect sizes are independent. When correlated effect sizes are analyzed using traditional univariate techniques, this assumption is violated. This research assesses the impact of dependence arising from treatment-control studies with multiple endpoints on homogeneity measures Q and I(2) in scenarios using the unbiased standardized-mean-difference effect size. Univariate and multivariate meta-analysis methods are examined. Conditions included different overall outcome effects, study sample sizes, numbers of studies, between-outcomes correlations, dependency structures, and ways of computing the correlation. The univariate approach used typical fixed-effects analyses whereas the multivariate approach used generalized least-squares (GLS) estimates of a fixed-effects model, weighted by the inverse variance-covariance matrix. Increased dependence among effect sizes led to increased Type I error rates from univariate models. When effect sizes were strongly dependent, error rates were drastically higher than nominal levels regardless of study sample size and number of studies. In contrast, using GLS estimation to account for multiple-endpoint dependency maintained error rates within nominal levels. Conversely, mean I(2) values were not greatly affected by increased amounts of dependency. Last, we point out that the between-outcomes correlation should be estimated as a pooled within-groups correlation rather than using a full-sample estimator that does not consider treatment/control group membership. Copyright © 2014 John Wiley & Sons, Ltd.

  15. Methods for increasing cooperation rates for surveys of family forest owners

    Treesearch

    Brett J. Butler; Jaketon H. Hewes; Mary L. Tyrrell; Sarah M. Butler

    2016-01-01

    To maximize the representativeness of results from surveys, coverage, sampling, nonresponse, measurement, and analysis errors must be minimized. Although not a cure-all, one approach for mitigating nonresponse errors is to maximize cooperation rates. In this study, personalizing mailings, token financial incentives, and the use of real stamps were tested for their...

  16. Teacher Induction in Australia: A Sample of What's Really Happening

    ERIC Educational Resources Information Center

    Hudson, Sue; Beutel, Denise; Hudson, Peter

    2009-01-01

    Retention rates and stress levels of beginning teachers are of concern. Well-planned induction programs can assist beginning teachers to make the transition successfully into the profession, which may increase retention rates. This qualitative, year-long study aims to explore and describe the induction experiences of eight beginning teachers as…

  17. Size-Based Separation of Particles and Cells Utilizing Viscoelastic Effects in Straight Microchannels.

    PubMed

    Liu, Chao; Xue, Chundong; Chen, Xiaodong; Shan, Lei; Tian, Yu; Hu, Guoqing

    2015-06-16

    Viscoelasticity-induced particle migration has recently received increasing attention due to its ability to obtain high-quality focusing over a wide range of flow rates. However, its application is limited to low throughput regime since the particles can defocus as flow rate increases. Using an engineered carrier medium with constant and low viscosity and strong elasticity, the sample flow rates are improved to be 1 order of magnitude higher than those in existing studies. Utilizing differential focusing of particles of different sizes, here, we present sheathless particle/cell separation in simple straight microchannels that possess excellent parallelizability for further throughput enhancement. The present method can be implemented over a wide range of particle/cell sizes and flow rates. We successfully separate small particles from larger particles, MCF-7 cells from red blood cells (RBCs), and Escherichia coli (E. coli) bacteria from RBCs in different straight microchannels. The proposed method could broaden the applications of viscoelastic microfluidic devices to particle/cell separation due to the enhanced sample throughput and simple channel design.

  18. Assessment of sperm hyperactivated motility and acrosome reaction can discriminate the use of spermatozoa for conventional in vitro fertilisation or intracytoplasmic sperm injection: preliminary results.

    PubMed

    Wiser, A; Sachar, S; Ghetler, Y; Shulman, A; Breitbart, H

    2014-04-01

    Basic semen analysis is insufficient for determining the fertility potential. The aim of this study was to determine if hyperactivated motility (HAM) and acrosome reaction (AR) can be useful tests for evaluating semen quality during male infertility evaluations and to help the clinician decide whether regular insemination or intracytoplasmic sperm injection (ICSI) is preferable during in vitro fertilisation. A prospective study was conducted. Patients with normal sperm according to World Health Organization guidelines who underwent IVF treatment and planned regular insemination were asked to participate. A portion of sperm sample was evaluated for HAM and AR on day of ovum pick up. In HAM assessment, 93.3% of patients with increased HAM had a high fertilisation rate compared with 64% in the group without increased HAM (P = 0.059). For the AR evaluation, 91.7% of samples with a low rate of spontaneous AR had a high fertilisation rate compared with 39.3% in the group with a high rate of spontaneous AR (P = 0.004). © 2013 Blackwell Verlag GmbH.

  19. Image Registration of Cone-Beam Computer Tomography and Preprocedural Computer Tomography Aids in Localization of Adrenal Veins and Decreasing Radiation Dose in Adrenal Vein Sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Busser, Wendy M. H., E-mail: wendy.busser@radboudumc.nl; Arntz, Mark J.; Jenniskens, Sjoerd F. M.

    2015-08-15

    PurposeWe assessed whether image registration of cone-beam computed tomography (CT) (CBCT) and contrast-enhanced CT (CE-CT) images indicating the locations of the adrenal veins can aid in increasing the success rate of first-attempts adrenal vein sampling (AVS) and therefore decreasing patient radiation dose.Materials and Methods CBCT scans were acquired in the interventional suite (Philips Allura Xper FD20) and rigidly registered to the vertebra in previously acquired CE-CT. Adrenal vein locations were marked on the CT image and superimposed with live fluoroscopy and digital-subtraction angiography (DSA) to guide the AVS. Seventeen first attempts at AVS were performed with image registration and retrospectivelymore » compared with 15 first attempts without image registration performed earlier by the same 2 interventional radiologists. First-attempt AVS was considered successful when both adrenal vein samples showed representative cortisol levels. Sampling time, dose-area product (DAP), number of DSA runs, fluoroscopy time, and skin dose were recorded.ResultsWithout image registration, the first attempt at sampling was successful in 8 of 15 procedures indicating a success rate of 53.3 %. This increased to 76.5 % (13 of 17) by adding CBCT and CE-CT image registration to AVS procedures (p = 0.266). DAP values (p = 0.001) and DSA runs (p = 0.026) decreased significantly by adding image registration guidance. Sampling and fluoroscopy times and skin dose showed no significant changes.ConclusionGuidance based on registration of CBCT and previously acquired diagnostic CE-CT can aid in enhancing localization of the adrenal veins thereby increasing the success rate of first-attempt AVS with a significant decrease in the number of used DSA runs and, consequently, radiation dose required.« less

  20. Picoelectrospray Ionization Mass Spectrometry Using Narrow-bore Chemically Etched Emitters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marginean, Ioan; Tang, Keqi; Smith, Richard D.

    2014-01-01

    Electrospray ionization mass spectrometry (ESI-MS) at flow rates below ~10 nL/min has been only sporadically explored due to difficulty in reproducibly fabricating emitters that can operate at lower flow rates. Here we demonstrate narrow orifice chemically etched emitters for stable electrospray at flow rates as low as 400 pL/min. Depending on the analyte concentration, we observe two types of MS signal response as a function of flow rate. At low concentrations, an optimum flow rate is observed slightly above 1 nL/min, while the signal decreases monotonically with decreasing flow rates at higher concentrations. In spite of lower MS signal, themore » ion utilization efficiency increases exponentially with decreasing flow rate in all cases. No unimolecular response was observed within this flow rate range during the analysis of an equimolar mixture of peptides, indicating that ionization efficiency is an analyte-dependent characteristic in given experimental conditions. While little to no gain in signal-to-noise was achieved at ultralow flow rates for concentration-limited analyses, experiments consuming the same amount of analyte suggest that mass-limited analyses will benefit strongly from the use of low flow rates and avoiding unnecessary sample dilution. By operating under optimal conditions, consumption of just 500 zmol of sample yielded signal-to-noise ratios ~10 for some peptides. These findings have important implications for the analysis of trace biological samples.« less

  1. Fuel cladding behavior under rapid loading conditions

    NASA Astrophysics Data System (ADS)

    Yueh, K.; Karlsson, J.; Stjärnsäter, J.; Schrire, D.; Ledergerber, G.; Munoz-Reja, C.; Hallstadius, L.

    2016-02-01

    A modified burst test (MBT) was used in an extensive test program to characterize fuel cladding failure behavior under rapid loading conditions. The MBT differs from a normal burst test with the use of a driver tube to simulate the expansion of a fuel pellet, thereby producing a partial strain driven deformation condition similar to that of a fuel pellet expansion in a reactivity insertion accident (RIA). A piston/cylinder assembly was used to pressurize the driver tube. By controlling the speed and distance the piston travels the loading rate and degree of sample deformation could be controlled. The use of a driver tube with a machined gauge section localizes deformation and allows for continuous monitoring of the test sample diameter change at the location of maximum hoop strain, during each test. Cladding samples from five irradiated fuel rods were tested between 296 and 553 K and loading rates from 1.5 to 3.5/s. The test rods included variations of Zircaloy-2 with different liners and ZIRLO, ranging in burn-up from 41 to 74 GWd/MTU. The test results show cladding ductility is strongly temperature and loading rate dependent. Zircaloy-2 cladding ductility degradation due to operational hydrogen pickup started to recover at approximately 358 K for test condition used in the study. This recovery temperature is strongly loading rate dependent. At 373 K, ductility recovery was small for loading rates less than 8 ms equivalent RIA pulse width, but longer than 8 ms the ductility recovery increased exponentially with increasing pulse width, consistent with literature observations of loading rate dependent brittle-to-ductile (BTD) transition temperature. The cladding ductility was also observed to be strongly loading rate/pulse width dependent for BWR cladding below the BTD temperature and Pressurized Water Reactor (PWR) cladding at both 296 and 553 K.

  2. Are catchment-wide erosion rates really "Catchment-Wide"? Effects of grain size on erosion rates determined from 10Be

    NASA Astrophysics Data System (ADS)

    Reitz, M. A.; Seeber, L.; Schaefer, J. M.; Ferguson, E. K.

    2012-12-01

    Early studies pioneering the method for catchment wide erosion rates by measuring 10Be in alluvial sediment were taken at river mouths and used the sand size grain fraction from the riverbeds in order to average upstream erosion rates and measure erosion patterns. Finer particles (<0.0625 mm) were excluded to reduce the possibility of a wind-blown component of sediment and coarser particles (>2 mm) were excluded to better approximate erosion from the entire upstream catchment area (coarse grains are generally found near the source). Now that the sensitivity of 10Be measurements is rapidly increasing, we can precisely measure erosion rates from rivers eroding active tectonic regions. These active regions create higher energy drainage systems that erode faster and carry coarser sediment. In these settings, does the sand-sized fraction fully capture the average erosion of the upstream drainage area? Or does a different grain size fraction provide a more accurate measure of upstream erosion? During a study of the Neto River in Calabria, southern Italy, we took 8 samples along the length of the river, focusing on collecting samples just below confluences with major tributaries, in order to use the high-resolution erosion rate data to constrain tectonic motion. The samples we measured were sieved to either a 0.125 mm - 0.710 mm fraction or the 0.125 mm - 4 mm fraction (depending on how much of the former was available). After measuring these 8 samples for 10Be and determining erosion rates, we used the approach by Granger et al. [1996] to calculate the subcatchment erosion rates between each sample point. In the subcatchments of the river where we used grain sizes up to 4 mm, we measured very low 10Be concentrations (corresponding to high erosion rates) and calculated nonsensical subcatchment erosion rates (i.e. negative rates). We, therefore, hypothesize that the coarser grain sizes we included are preferentially sampling a smaller upstream area, and not the entire upstream catchment, which is assumed when measurements are based solely on the sand sized fraction. To test this hypothesis, we used samples with a variety of grain sizes from the Shillong Plateau. We sieved 5 samples into three grain size fractions: 0.125 mm - 710 mm, 710 mm - 4 mm, and >4 mm and measured 10Be concentrations in each fraction. Although there is some variation in the grain size fraction that yields the highest erosion rate, generally, the coarser grain size fractions have higher erosion rates. More significant are the results when calculating the subcatchment erosion rates, which suggest that even medium sized grains (710 mm - 4 mm) are sampling an area smaller than the entire upstream area; this finding is consistent with the nonsensical results from the Neto River study. This result has numerous implications for the interpretations of 10Be erosion rates: most importantly, an alluvial sample may not be averaging the entire upstream area, even when using the sand size fraction - resulting erosion rates more pertinent for that sample point rather than the entire catchment.

  3. High-Flow-Rate Impinger for the Study of Concentration, Viability, Metabolic Activity, and Ice-Nucleation Activity of Airborne Bacteria.

    PubMed

    Šantl-Temkiv, Tina; Amato, Pierre; Gosewinkel, Ulrich; Thyrhaug, Runar; Charton, Anaïs; Chicot, Benjamin; Finster, Kai; Bratbak, Gunnar; Löndahl, Jakob

    2017-10-03

    The study of airborne bacteria relies on a sampling strategy that preserves their integrity and in situ physiological state, e.g. viability, cultivability, metabolic activity, and ice-nucleation activity. Because ambient air harbors low concentrations of bacteria, an effective bioaerosol sampler should have a high sampling efficiency and a high airflow. We characterize a high-flow-rate impinger with respect to particle collection and retention efficiencies in the range 0.5-3.0 μm, and we investigated its ability to preserve the physiological state of selected bacterial species and seawater bacterial community in comparison with four commercial bioaerosol samplers. The collection efficiency increased with particle size and the cutoff diameter was between 0.5 and 1 μm. During sampling periods of 120-300 min, the impinger retained the cultivability, metabolic activity, viability, and ice-nucleation activity of investigated bacteria. Field studies in semiurban, high-altitude, and polar environments included periods of low bacterial air concentrations, thus demonstrating the benefits of the impinger's high flow rate. In conclusion, the impinger described here has many advantages compared with other bioaerosol samplers currently on the market: a potential for long sampling time, a high flow rate, a high sampling and retention efficiency, low costs, and applicability for diverse downstream microbiological and molecular analyses.

  4. The mineralogical phase transformation of invisible gold-concentrate by microwave heating, and enhancement of their gold leaching rate

    NASA Astrophysics Data System (ADS)

    Bak, Geonyoung; Kim, Bongju; Choi, Nagchoul; Park*, Cheonyoung

    2015-04-01

    In this study, in order to obtain the maximum Au leaching rate, an invisible gold concentrate sample was microwave-treated and a thiourea leaching experiment was performed. It is found that gold exists as invisible as a result of observation with an optical microscope and an electron microscope. As the invisible gold concentrate sample was exposed to microwave longer, its temperature and weight loss were increased together and its S content was decreased. The conditions for the maximum Au leaching rate and the fast leaching effect were a particle size of -325×400 mesh, exposure to microwave for 70 minutes, 1.0 g of thiourea, 0.0504 g of sodium sulfite and 0.425 g of ferric sulfate. However, the condition under which Au was leached out to the maximum was applied to the control sample, but its Au leaching rate was just in a range of 78% to 88%. Such results suggest that the effect of sodium sulfite and ferric sulfate was more effective in the microwave-treated sample than in the control sample. Therefore, it was confirmed that the complete and very fast Au leaching can be achieved by means of the microwave pretreatment of invisible gold concentrate.

  5. High-speed fixed-target serial virus crystallography

    DOE PAGES

    Roedig, Philip; Ginn, Helen M.; Pakendorf, Tim; ...

    2017-06-19

    Here, we report a method for serial X-ray crystallography at X-ray free-electron lasers (XFELs), which allows for full use of the current 120-Hz repetition rate of the Linear Coherent Light Source (LCLS). Using a micropatterned silicon chip in combination with the high-speed Roadrunner goniometer for sample delivery, we were able to determine the crystal structures of the picornavirus bovine enterovirus 2 (BEV2) and the cytoplasmic polyhedrosis virus type 18 polyhedrin, with total data collection times of less than 14 and 10 min, respectively. Our method requires only micrograms of sample and should therefore broaden the applicability of serial femtosecond crystallographymore » to challenging projects for which only limited sample amounts are available. By synchronizing the sample exchange to the XFEL repetition rate, our method allows for most efficient use of the limited beam time available at XFELs and should enable a substantial increase in sample throughput at these facilities.« less

  6. High-speed fixed-target serial virus crystallography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roedig, Philip; Ginn, Helen M.; Pakendorf, Tim

    Here, we report a method for serial X-ray crystallography at X-ray free-electron lasers (XFELs), which allows for full use of the current 120-Hz repetition rate of the Linear Coherent Light Source (LCLS). Using a micropatterned silicon chip in combination with the high-speed Roadrunner goniometer for sample delivery, we were able to determine the crystal structures of the picornavirus bovine enterovirus 2 (BEV2) and the cytoplasmic polyhedrosis virus type 18 polyhedrin, with total data collection times of less than 14 and 10 min, respectively. Our method requires only micrograms of sample and should therefore broaden the applicability of serial femtosecond crystallographymore » to challenging projects for which only limited sample amounts are available. By synchronizing the sample exchange to the XFEL repetition rate, our method allows for most efficient use of the limited beam time available at XFELs and should enable a substantial increase in sample throughput at these facilities.« less

  7. Determination of an effective sampling regime to detect salmonella enteritidis in the environment of poultry units.

    PubMed

    Davies, R H; Wray, C

    1996-05-01

    A study of the dissemination of Salmonella enteritidis in the poultry breeder industry in the UK showed that the choice of sites for sampling the environment of occupied houses and empty houses which had been disinfected after depopulation had a significant influence on the outcome. Increased isolation rates could be achieved by sampling nest box floors and dust in open slave feed hoppers in occupied poultry houses. Nest box floors were the most sensitive sites for detection of residual environmental contamination in poultry houses where enrofloxacin treatment had been used. Floor sweepings, nest box floors, slave feed hoppers, hydrated wall fabric junctions and high beams and pipes were the most sensitive sample sites in cleansed and disinfected poultry houses. The use of universal disinfectant neutralisers gave good results in laboratory trials but appeared to reduce the isolation rate from field samples.

  8. High-speed fixed-target serial virus crystallography

    PubMed Central

    Roedig, Philip; Ginn, Helen M.; Pakendorf, Tim; Sutton, Geoff; Harlos, Karl; Walter, Thomas S.; Meyer, Jan; Fischer, Pontus; Duman, Ramona; Vartiainen, Ismo; Reime, Bernd; Warmer, Martin; Brewster, Aaron S.; Young, Iris D.; Michels-Clark, Tara; Sauter, Nicholas K.; Kotecha, Abhay; Kelly, James; Rowlands, David J.; Sikorsky, Marcin; Nelson, Silke; Damiani, Daniel S.; Alonso-Mori, Roberto; Ren, Jingshan; Fry, Elizabeth E.; David, Christian; Stuart, David I.; Wagner, Armin; Meents, Alke

    2017-01-01

    We report a method for serial X-ray crystallography at X-ray free electron lasers (XFELs), which allows for full use of the current 120 Hz repetition rate of the Linear Coherent Light Source (LCLS). Using a micro-patterned silicon chip in combination with the high-speed Roadrunner goniometer for sample delivery we were able to determine the crystal structures of a picornavirus, bovine enterovirus 2 (BEV2), and the cytoplasmic polyhedrosis virus type 18 polyhedrin. Total data collection times were less than 14 and 10 minutes, respectively. Our method requires only micrograms of sample and will therefore broaden the applicability of serial femtosecond crystallography to challenging projects for which only limited sample amounts are available. By synchronizing the sample exchange to the XFEL repetition rate, our method allows for the most efficient use of the limited beamtime available at XFELs and should enable a substantial increase in sample throughput at these facilities. PMID:28628129

  9. Experimental Deformation of Dehydrating Antigorite: Challenging Models of Dehydration Embrittlement

    NASA Astrophysics Data System (ADS)

    Hirth, Greg; Chernak, Linda

    2010-05-01

    To test the hypothesis that intermediate depth earthquakes in subduction zones are caused by the dehydration of hydrous phases, we conducted temperature-ramping experiments on antigorite serpentinite. Cold-pressed powdered samples of antigorite were deformed to a high differential stress at 400°C and 1.0 GPa, within the antigorite stability field, where we have shown that deformation localizes. Temperature was then increased at different rates, 1800°C/hr and 180°C/hr, to cross the reaction boundary while the sample continued to deform; samples were deformed at strain rates of 10-4 s-1, 10-5 s-1 and 10-6 s-1. Two additional experiments were conducted in a similar manner at 300°C, 1.5 GPa and 10-5 s-1 but samples remained 'statically' at high stress during the temperature increase. Our results show that although the decrease in stress during temperature ramping is large, stress relaxes stably, even after dehydration. We find that the slopes of the unloading curves are approximately the same for constant values of the ratio (strain rate/ramp rate) and that the unloading slope is greater for higher values of this ratio. In addition, we find that the unloading curves with the greatest slopes are similar to the apparatus compliance, suggesting that we are generating 'slow earthquakes' in our experiments over the course 5 to 10s of minutes. A strain rate stepping experiment indicates that antigorite has velocity strengthening behavior at 700°C and 1.5 GPa suggesting that as soon as an instability develops in the antigorite, the material strengthens sufficiently to not go unstable. Our results thus suggest that antigorite dehydration does not result in 'dehydration embrittlement' but that it may promote slow earthquakes. We have also conducted a preliminary experiment to study the role of effective pressure on deformation behavior after dehydration. A cold-pressed powdered sample of antigorite with a small core of coarse-grained olivine at one end was deformed at 700°C, 1.5 GPa and a strain rate of 10-5 s-1. This sample had a strength of 300 MPa, which is significantly higher than samples deformed at the same conditions without olivine present; strengths were approximately 100 MPa for these samples. We hypothesize that the highly porous and permeable olivine layer provided a reservoir for the water released by the dehydration reaction and suggests that the presence of water causes the strength of antigorite to decrease.

  10. Investigating risk factors and possible infectious aetiologies of mummified fetuses on a large piggery in Australia.

    PubMed

    Dron, N; Hernández-Jover, M; Doyle, R E; Holyoake, P K

    2014-12-01

    To investigate risk factors and potential infectious aetiologies of an increased mummification rate (>2%) identified over time on a 1200-sow farrow-to-finish farm in Australia. Association of potential non-infectious risk factors and the mummification rate was investigated using 15 years of breeding herd data (40,940 litters) and logistic regression analysis. Samples from a limited number of mummified fetuses were taken to identify potential infectious aetiologies (porcine parvovirus, Leptospira pomona, porcine circovirus type 2, Bungowannah virus and enterovirus). Logistic regression analysis suggested that the mummification rate was significantly associated with sow breed and parity, year and total born and stillborn piglets per litter. The mummification rate was lower (P < 0.001) in Landrace (3.4%) and Large White (2.6%) sows than in Duroc sows (4.9%). Gilts (2.9%) had a lower (P < 0.001) mummification rate than older sows. The mummification rate increased with total born litter size and decreased with the number of stillborn piglets (P < 0.001). A clustering effect within individual sows was identified, indicating that some sows with mummified fetuses in a litter were more likely to have repeated mummifications in subsequent litters. No infectious agents were identified in the samples taken. Results from this study suggest that the increased mummification rate identified over time on this farm is likely to be a non-infectious multifactorial problem predisposing the occurrence of mummification. Further research is required to better understand the pathophysiology of mummification and the role that different non-infectious factors play in the occurrence of mummified fetuses. © 2014 Australian Veterinary Association.

  11. Use of a (137)Cs re-sampling technique to investigate temporal changes in soil erosion and sediment mobilisation for a small forested catchment in southern Italy.

    PubMed

    Porto, Paolo; Walling, Des E; Alewell, Christine; Callegari, Giovanni; Mabit, Lionel; Mallimo, Nicola; Meusburger, Katrin; Zehringer, Markus

    2014-12-01

    Soil erosion and both its on-site and off-site impacts are increasingly seen as a serious environmental problem across the world. The need for an improved evidence base on soil loss and soil redistribution rates has directed attention to the use of fallout radionuclides, and particularly (137)Cs, for documenting soil redistribution rates. This approach possesses important advantages over more traditional means of documenting soil erosion and soil redistribution. However, one key limitation of the approach is the time-averaged or lumped nature of the estimated erosion rates. In nearly all cases, these will relate to the period extending from the main period of bomb fallout to the time of sampling. Increasing concern for the impact of global change, particularly that related to changing land use and climate change, has frequently directed attention to the need to document changes in soil redistribution rates within this period. Re-sampling techniques, which should be distinguished from repeat-sampling techniques, have the potential to meet this requirement. As an example, the use of a re-sampling technique to derive estimates of the mean annual net soil loss from a small (1.38 ha) forested catchment in southern Italy is reported. The catchment was originally sampled in 1998 and samples were collected from points very close to the original sampling points again in 2013. This made it possible to compare the estimate of mean annual erosion for the period 1954-1998 with that for the period 1999-2013. The availability of measurements of sediment yield from the catchment for parts of the overall period made it possible to compare the results provided by the (137)Cs re-sampling study with the estimates of sediment yield for the same periods. In order to compare the estimates of soil loss and sediment yield for the two different periods, it was necessary to establish the uncertainty associated with the individual estimates. In the absence of a generally accepted procedure for such calculations, key factors influencing the uncertainty of the estimates were identified and a procedure developed. The results of the study demonstrated that there had been no significant change in mean annual soil loss in recent years and this was consistent with the information provided by the estimates of sediment yield from the catchment for the same periods. The study demonstrates the potential for using a re-sampling technique to document recent changes in soil redistribution rates. Copyright © 2014. Published by Elsevier Ltd.

  12. Experiment Using Infrared Spectroscopy to Study the Effect of Soil Characteristics upon the Rate of Trichloroethylene Desorption

    DTIC Science & Technology

    1994-09-01

    34 Journal of Environmental Quality, 17: 149-152 (January 1988). Serway , Raymond A . Physics for Scientists and Engineers / with Modern Physics. Saunders...no Adx), to the sample cross-sectional area ( Serway , 1983: 1068). The relationship may be presented as follows: dN n nAadx (11) N A or -- = n a dx...absorbed increases exponentially with the length of the path they must travel through a TCE contaminated sample ( Serway , 1983: 1068). Also, increasing the

  13. Strain-Rate Dependence of Deformation-Twinning in Tantalum

    NASA Astrophysics Data System (ADS)

    Abeywardhana, Jayalath; Germann, Tim; Ravelo, Ramon

    2017-06-01

    Large-Scale molecular dynamics (MD) simulations are used to model quasi-isentropic compression and expansion (QIC) in tantalum crystals varying the rate of deformation between the range 108 -1012s-1 and compressive pressures up to 100 GPa. The atomic interactions were modeled employing an embedded-atom method (EAM) potential of Ta. Isentropic expansion was done employing samples initially compressed to pressures of 60 and 100 GPa followed by uniaxial and quasi-isentropically expansion to zero pressure. The effect of initial dislocation density on twinning was also examined by varying the initial defect density of the Ta samples (1010 -1012cm-2). At these high-strain rates, a threshold in strain-rate on deformation twining is observed. Under expansion or compression, deformation twinning increases with strain rate for strain-rates >109s-1 . Below this value, small fraction of twins nucleates but anneal out with time. Samples with lower fraction of twins equilibrate to defect states containing higher screw dislocation densities from those with initially higher twinning fractions. This work was supported by the Department of Energy under contract DE-AC52-06NA25396 and by the Air Force Office of Scientific Research under AFOSR Award No. FA9550-12-1-0476.

  14. Ultrasound assisted biogas production from landfill leachate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oz, Nilgün Ayman, E-mail: nilgunayman@comu.edu.tr; Yarimtepe, Canan Can

    Highlights: • Effect of low frequency ultrasound pretreatment on leachate was investigated. • Three different ultrasound energy inputs (200, 400 and 600 W/l) was applied. • Low-frequency ultrasound treatment increased soluble COD in landfill leachate. • Application of ultrasound to leachate increased biogas production about 40%. • Application of ultrasound to leachate increased total methane production rate about 20%. - Abstract: The aim of this study is to increase biogas production and methane yield from landfill leachate in anaerobic batch reactors by using low frequency ultrasound as a pretreatment step. In the first part of the study, optimum conditions formore » solubilization of organic matter in leachate samples were investigated using various sonication durations at an ultrasound frequency of 20 kHz. The level of organic matter solubilization during ultrasonic pretreatment experiments was determined by calculating the ratio of soluble chemical oxygen demand (sCOD) to total chemical oxygen demand (tCOD). The sCOD/tCOD ratio was increased from 47% in raw leachate to 63% after 45 min sonication at 600 W/l. Non-parametric Friedman’s test indicated that ultrasonic pretreatment has a significant effect on sCOD parameter for leachate (p < 0.05). In the second part of the study, anaerobic batch reactors were operated for both ultrasonically pretreated and untreated landfill leachate samples in order to assess the effect of sonication on biogas and methane production rate. In anaerobic batch reactor feed with ultrasonically pretreated leachate, 40% more biogas was obtained compared to the control reactor. For statistical analysis, Mann–Whitney U test was performed to compare biogas and methane production rates for raw and pretreated leachate samples and it has been found that ultrasonic pretreatment significantly enhanced biogas and methane production rates from leachate (p < 0.05) in anaerobic batch reactors. The overall results showed that low frequency ultrasound pretreatment can be potentially used for wastewater management especially with integration of anaerobic processes.« less

  15. Seasonality, Rather than Nutrient Addition or Vegetation Types, Influenced Short-Term Temperature Sensitivity of Soil Organic Carbon Decomposition

    PubMed Central

    He, Feng-Peng; Wang, Wei

    2016-01-01

    The response of microbial respiration from soil organic carbon (SOC) decomposition to environmental changes plays a key role in predicting future trends of atmospheric CO2 concentration. However, it remains uncertain whether there is a universal trend in the response of microbial respiration to increased temperature and nutrient addition among different vegetation types. In this study, soils were sampled in spring, summer, autumn and winter from five dominant vegetation types, including pine, larch and birch forest, shrubland, and grassland, in the Saihanba area of northern China. Soil samples from each season were incubated at 1, 10, and 20°C for 5 to 7 days. Nitrogen (N; 0.035 mM as NH4NO3) and phosphorus (P; 0.03 mM as P2O5) were added to soil samples, and the responses of soil microbial respiration to increased temperature and nutrient addition were determined. We found a universal trend that soil microbial respiration increased with increased temperature regardless of sampling season or vegetation type. The temperature sensitivity (indicated by Q10, the increase in respiration rate with a 10°C increase in temperature) of microbial respiration was higher in spring and autumn than in summer and winter, irrespective of vegetation type. The Q10 was significantly positively correlated with microbial biomass and the fungal: bacterial ratio. Microbial respiration (or Q10) did not significantly respond to N or P addition. Our results suggest that short-term nutrient input might not change the SOC decomposition rate or its temperature sensitivity, whereas increased temperature might significantly enhance SOC decomposition in spring and autumn, compared with winter and summer. PMID:27070782

  16. Outlier removal, sum scores, and the inflation of the Type I error rate in independent samples t tests: the power of alternatives and recommendations.

    PubMed

    Bakker, Marjan; Wicherts, Jelte M

    2014-09-01

    In psychology, outliers are often excluded before running an independent samples t test, and data are often nonnormal because of the use of sum scores based on tests and questionnaires. This article concerns the handling of outliers in the context of independent samples t tests applied to nonnormal sum scores. After reviewing common practice, we present results of simulations of artificial and actual psychological data, which show that the removal of outliers based on commonly used Z value thresholds severely increases the Type I error rate. We found Type I error rates of above 20% after removing outliers with a threshold value of Z = 2 in a short and difficult test. Inflations of Type I error rates are particularly severe when researchers are given the freedom to alter threshold values of Z after having seen the effects thereof on outcomes. We recommend the use of nonparametric Mann-Whitney-Wilcoxon tests or robust Yuen-Welch tests without removing outliers. These alternatives to independent samples t tests are found to have nominal Type I error rates with a minimal loss of power when no outliers are present in the data and to have nominal Type I error rates and good power when outliers are present. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  17. Sampling factors influencing accuracy of sperm kinematic analysis.

    PubMed

    Owen, D H; Katz, D F

    1993-01-01

    Sampling conditions that influence the accuracy of experimental measurement of sperm head kinematics were studied by computer simulation methods. Several archetypal sperm trajectories were studied. First, mathematical models of typical flagellar beats were input to hydrodynamic equations of sperm motion. The instantaneous swimming velocities of such sperm were computed over sequences of flagellar beat cycles, from which the resulting trajectories were determined. In a second, idealized approach, direct mathematical models of trajectories were utilized, based upon similarities to the previous hydrodynamic constructs. In general, it was found that analyses of sampling factors produced similar results for the hydrodynamic and idealized trajectories. A number of experimental sampling factors were studied, including the number of sperm head positions measured per flagellar beat, and the time interval over which these measurements are taken. It was found that when one flagellar beat is sampled, values of amplitude of lateral head displacement (ALH) and linearity (LIN) approached their actual values when five or more sample points per beat were taken. Mean angular displacement (MAD) values, however, remained sensitive to sampling rate even when large sampling rates were used. Values of MAD were also much more sensitive to the initial starting point of the sampling procedure than were ALH or LIN. On the basis of these analyses of measurement accuracy for individual sperm, simulations were then performed of cumulative effects when studying entire populations of motile cells. It was found that substantial (double digit) errors occurred in the mean values of curvilinear velocity (VCL), LIN, and MAD under the conditions of 30 video frames per second and 0.5 seconds of analysis time. Increasing the analysis interval to 1 second did not appreciably improve the results. However, increasing the analysis rate to 60 frames per second significantly reduced the errors. These findings thus suggest that computer-aided sperm analysis (CASA) application at 60 frames per second will significantly improve the accuracy of kinematic analysis in most applications to human and other mammalian sperm.

  18. Caesarean section rate and cost control effectiveness of case payment reform in the new cooperative medical scheme for delivery: evidence from Xi County, China.

    PubMed

    Liu, Shuang; Wang, Jing; Zhang, Liang; Zhang, Xiang

    2018-03-09

    In China, increases in both the caesarean section (CS) rates and delivery costs have raised questions regarding the reform of the medical insurance payment system. Case payment is useful for regulating the behaviour of health providers and for controlling the CS rates and excessive increases in medical expenses. New Cooperative Medical Scheme (NCMS) agencies in Xi County in Henan Province piloted a case payment reform (CPR) in delivery for inpatients. We aimed to observe the changes in the CS rates, compare the changes in delivery-related variables, and identify variables related to delivery costs before and after the CPR in Xi County. Overall, 28,314 cases were selected from the Xi County NCMS agency from 2009 to 2010 and from 2014 to 2015. One-way ANOVA and chi-square tests were used to compare the distributions of CS and vaginal delivery (VD) before and after the CPR under different indicators. We applied multivariate linear regressions for the total medical cost of the VD and CS groups and total samples to identify the relationships between medical expenses and variables. The CS rates in Xi County increased from 26.1% to 32.5% after the CPR. The length of stay (LOS), total medical cost, and proportion of county hospitals increased in the CS and VD groups after the CPR, which had significant differences. The total medical cost in the CS and VD groups as well as the total samples was significantly influenced by inpatient age, LOS, and hospital type, and had a significant correlation with the CPR in the VD group and the total samples. The CPR might fail to control the growth of unreasonable medical expenses and regulate the behaviour of providers, which possibly resulted from the unreasonable compensation standard of case payments, prolonged LOS, and the increasing proportion of county hospitals. The NCMS should modify the case payment standard of delivery to inhibit providers' motivation to render CS services. The LOS should be controlled by implementing clinical guidelines, and a reference system should be established to guide patients in choosing reasonable hospitals.

  19. Poisson Statistics of Combinatorial Library Sampling Predict False Discovery Rates of Screening

    PubMed Central

    2017-01-01

    Microfluidic droplet-based screening of DNA-encoded one-bead-one-compound combinatorial libraries is a miniaturized, potentially widely distributable approach to small molecule discovery. In these screens, a microfluidic circuit distributes library beads into droplets of activity assay reagent, photochemically cleaves the compound from the bead, then incubates and sorts the droplets based on assay result for subsequent DNA sequencing-based hit compound structure elucidation. Pilot experimental studies revealed that Poisson statistics describe nearly all aspects of such screens, prompting the development of simulations to understand system behavior. Monte Carlo screening simulation data showed that increasing mean library sampling (ε), mean droplet occupancy, or library hit rate all increase the false discovery rate (FDR). Compounds identified as hits on k > 1 beads (the replicate k class) were much more likely to be authentic hits than singletons (k = 1), in agreement with previous findings. Here, we explain this observation by deriving an equation for authenticity, which reduces to the product of a library sampling bias term (exponential in k) and a sampling saturation term (exponential in ε) setting a threshold that the k-dependent bias must overcome. The equation thus quantitatively describes why each hit structure’s FDR is based on its k class, and further predicts the feasibility of intentionally populating droplets with multiple library beads, assaying the micromixtures for function, and identifying the active members by statistical deconvolution. PMID:28682059

  20. Effect of the gamma radiation dose rate on psychrotrophic bacteria, thiobarbituric acid reactive substances, and sensory characteristics of mechanically deboned chicken meat.

    PubMed

    Brito, Poliana P; Azevedo, Heliana; Cipolli, Kátia M V A B; Fukuma, Henrique T; Mourão, Gerson B; Roque, Cláudio V; Miya, Norma T; Pereira, José L

    2011-03-01

    Frozen samples of mechanically deboned chicken meat (MDCM) with skin were irradiated with gamma radiation doses of 0.0 kGy (control) and 3 kGy at 2 different radiation dose rates: 0.32 kGy/h (3 kGy) and 4.04 kGy/h (3 kGy). Batches of irradiated and control samples were evaluated during 11 d of refrigerated (2 ± 1 °C) storage for the following parameters: total psychrotrophic bacteria count, thiobarbituric acid reactive substances (TBARS), evaluation of objective color (L*, a*, and b*) and a sensory evaluation (irradiated odor, oxidized odor, pink and brown colors). No statistical difference (P > 0.05) was found amongst the TBARS values obtained for the MDCM samples irradiated with dose rates of 0.32 and 4.04 kGy/h. There was a significant increase (P < 0.05) in the psychrotrophic bacterial count as from the 7th day of refrigerated storage, for the MDCM samples irradiated at the dose rate of 4.04 kGy/h. With respect to the attribute of oxidized odor, the samples irradiated with a dose rate of 0.32 kGy/h showed a stronger intensity and were significantly different (P < 0.05) from the sample irradiated with a dose rate of 4.04 kGy/h on days 0 and 2 of refrigerated storage. Irradiation with a dose rate of 4.04 kGy/h (3 kGy) was shown to be the best condition for the processing of MDCM according to the evaluation of all the variables, under the conditions of this study. Practical Application:  The results obtained for the application of different dose rates of ionizing radiation to mechanically deboned chicken meat will provide the food industry with information concerning the definition of the best processing conditions to maximize the sensory and food quality.

  1. Effect of maternal diabetes on female offspring

    PubMed Central

    Martins, Juliana de Oliveira; Panício, Maurício Isaac; Dantas, Marcos Paulo Suehiro; Gomes, Guiomar Nascimento

    2014-01-01

    Objective To evaluate the effect of maternal diabetes on the blood pressure and kidney function of female offspring, as well as if such changes exacerbate during pregnancy. Methods Diabetes mellitus was induced in female rats with the administration of streptozotocin in a single dose, one week before mating. During pregnancy, blood pressure was measured through plethysmography. On the 20th day of pregnancy, the animals were placed for 24 hours in metabolic cages to obtain urine samples. After the animals were removed from the cages, blood samples were withdrawn. One month after pregnancy, new blood and urine sample were collected. Kidney function was evaluated through proteinuria, plasma urea, plasma creatinine, creatinine excretion rate, urinary flow, and creatinine clearance. Results The female offspring from diabetic mothers showed an increase in blood pressure, and a decrease in glomerular filtration rate in relation to the control group. Conclusion Hyperglycemia during pregnancy was capable of causing an increase in blood pressure and kidney dysfunction in the female offspring. PMID:25628190

  2. A Large-Sample Test of a Semi-Automated Clavicle Search Engine to Assist Skeletal Identification by Radiograph Comparison.

    PubMed

    D'Alonzo, Susan S; Guyomarc'h, Pierre; Byrd, John E; Stephan, Carl N

    2017-01-01

    In 2014, a morphometric capability to search chest radiograph databases by quantified clavicle shape was published to assist skeletal identification. Here, we extend the validation tests conducted by increasing the search universe 18-fold, from 409 to 7361 individuals to determine whether there is any associated decrease in performance under these more challenging circumstances. The number of trials and analysts were also increased, respectively, from 17 to 30 skeletons, and two to four examiners. Elliptical Fourier analysis was conducted on clavicles from each skeleton by each analyst (shadowgrams trimmed from scratch in every instance) and compared to the search universe. Correctly matching individuals were found in shortlists of 10% of the sample 70% of the time. This rate is similar to, although slightly lower than, rates previously found for much smaller samples (80%). Accuracy and reliability are thereby maintained, even when the comparison system is challenged by much larger search universes. © 2016 American Academy of Forensic Sciences.

  3. Superimpositional assessment of treatment-associated changes in the temporomandibular joint and the mandibular symphysis.

    PubMed

    Baumrind, S; Korn, E L; Isaacson, R J; West, E E; Molthen, R

    1983-12-01

    This article analyzes differences in the measured displacement of the condyle and of progonion when different vectors of force are delivered to the maxilla in the course of non-full-banded, Phase 1, mixed-dentition treatment for the correction of Class II malocclusion. The 238-case sample is identical to that for which changes in other parameters of facial form have been reported previously. Relative to superimposition on anterior cranial base and measured in a Frankfort-plane-determined coordinate system, we have attempted to identify and quantitate (1) the displacement of each structure which results from local remodeling and (2) the displacement of each structure which occurs as a secondary consequence of changes in other regions of the skull. We have also attempted to isolate treatment effects from those attributable to spontaneous growth and development. At the condyle, we note that in all three treatment groups and in the control group there is a small but real downward and backward displacement of the glenoid fossa. This change is not treatment induced but, rather, is associated with spontaneous growth and development. (See Fig. 5.) Some interesting differences in pattern of "growth at the condyle" were noted between samples. In the intraoral (modified activator) sample, there were small but statistically significant increases in growth rate as compared to the untreated group of Class II controls. To our surprise, similar statistically significant increases over the growth rate of the control group were noted in the cervical sample. (See Table III, variables 17 and 18.) Small but statistically significant differences between treatments were also noted in the patterns of change at pogonion. As compared to the untreated control group, the rate of total displacement in the modified activator group was significantly greater in the forward direction, while the rate of total displacement in the cervical group was significantly greater in the downward direction. There were no statistically significant differences in the rate of total displacement of pogonion between the high-pull sample and the control sample. (See Table IV, variables 21 and 22.

  4. Threat of drug resistant Staphylococcus aureus to health in Nepal

    PubMed Central

    2014-01-01

    Background Staphylococcus aureus is the most commonly isolated organism from the different clinical samples in hospital. The emergence and dissemination of methicillin resistant Staphylococcus aureus (MRSA) and growing resistance to non-beta-lactam antibiotics is making treatment of infections due to this organism increasingly difficult. Methods This study was conducted to determine the frequency of Staphylococcus aureus isolated from different clinical samples, rates of MRSA and full antibiotic susceptibility profiles. Clinical samples were cultured and Staphylococcus aureus was identified using standard microbiological methods recommended by the American Society for Microbiology (ASM). Methicillin resistance was confirmed using cefoxitin and oxacillin disks. Inducible clindamycin resistance was identified using D-zone test. Results From the processed samples, 306 isolates of Staphylococcus aureus were recovered. All the isolates were susceptible to vancomycin and teicoplanin. Methicillin resistance was observed in 43.1% of isolates while inducible clindamycin resistance in 12.4% of the isolates. Conclusions The results of our study reveals that rates of resistance to commonly prescribed antibiotics in Staphylococcus aureus clinical isolates is high. In particular, rate of methicillin resistance is alarming, prompting concern on the rational use of antibiotics and vigilant laboratory-based surveillance of resistance rates in Nepal. PMID:24655316

  5. Rupture of a highly stretchable acrylic dielectric elastomer

    NASA Astrophysics Data System (ADS)

    Pharr, George; Sun, Jeong-Yun; Suo, Zhigang

    2012-02-01

    Dielectric elastomers have found widespread application as energy harvesters, actuators, and sensors. In practice these elastomers are subject to large tensile stretches, which potentially can lead to mechanical fracture. In this study, we have examined fracture properties of the commercial acrylic elastomer VHB 4905. We have found that inserting a pre-cut into the material drastically reduces the stretch at rupture from λrup = 9.43±1.05 for pristine samples down to only λrup = 3.63±0.45 for the samples with a pre-cut. Furthermore, using ``pure-shear'' test specimens with a pre-crack, we have measured the fracture energy and stretch at rupture as a function of the sample geometry. The stretch at rupture was found to decrease with sample height, which agrees with an analytical prediction. Additionally, we have measured the fracture energy as a function of stretch-rate. The apparent fracture energy was found to increase with stretch-rate from γ 1500 J/m^2 to γ 5000 J/m^2 for the investigated rates of deformation. This phenomenon is due to viscoelastic properties of VHB 4905, which result in an apparent stiffening for sufficiently large stretch-rates.

  6. Kinetic study of corn straw pyrolysis: comparison of two different three-pseudocomponent models.

    PubMed

    Li, Zhengqi; Zhao, Wei; Meng, Baihong; Liu, Chunlong; Zhu, Qunyi; Zhao, Guangbo

    2008-11-01

    With heating rates of 20, 50 and 100 K min(-1), the thermal decomposition of corn straw samples (corn stalks skins, corn stalks cores, corn bracts and corn leaves) were studied using thermogravimetric analysis. The maximum pyrolysis rates increased with the heating rate increasing and the temperature at the peak pyrolysis rate also increased. Assuming the addition of three independent parallel reactions, corresponding to three pseudocomponents linked to the hemicellulose, cellulose and lignin, two different three-pseudocomponent models were used to simulate the corn straw pyrolysis. Model parameters of pyrolysis were given. It was found that the three-pseudocomponent model with n-order kinetics was more accurate than the model with first-order kinetics at most cases. It showed that the model with n-order kinetics was more accurate to describe the pyrolysis of the hemicellulose.

  7. Study of Survival Rate After Cardiopulmonary Resuscitation (CPR) in Hospitals of Kermanshah in 2013

    PubMed Central

    Goodarzi, Afshin; Jalali, Amir; Almasi, Afshin; Naderipour, Arsalan; Kalhori, Reza Pourmirza; Khodadadi, Amineh

    2015-01-01

    Background: After CPR, the follow-up of survival rate and caused complications are the most important practices of the medical group. This study was performed aimed at determining the follow-up results after CPR in patients of university hospitals in Kermanshah in 2014. Methods: In this prospective study, 320 samples were examined. A purposive sampling method was used, and data was collected using a researcher-made information form with content and face validity and reliability of r= 0.79. Data was analyzed with STATA9 software and statistical tests, including calculation of the success rate, relative risk (RR), chi-square and Fisher at significance level of P < 0.05. Results: The initial success rate of cardiopulmonary resuscitation was equal to 15.3%, while the ultimate success rate (discharged alive from the hospital) was as 10.6%. The six-month success rate after resuscitation was 8.78% than those who were discharged alive. There were no significant statistical differences between different age groups regarding the initial success rate of resuscitation (P = 0.14), and the initial resuscitation success rate was higher in patients in morning shift (P = 0.02). Conclusion: By the results of study, it is recommended to increase the medical - nursing knowledge and techniques for personnel in the evening and night shifts. Also, an appropriate dissemination of health care staff in working shifts should be done to increase the success rate of CPR procedure. PMID:25560341

  8. Seroprevalence of Dengue Fever in US Army Special Operations Forces: Initial Results and the Way Ahead.

    PubMed

    Caci, Jennifer B; Blaylock, Jason M; De La Barrera, Rafael; Griggs, April N; Lin, Leyi; Jarman, Richard G; Thomas, Stephen J; Lyons, Arthur G

    2014-01-01

    The endemicity of dengue fever (DF) and, consequently, sequelae of DF are increasing worldwide. The increases are largely a result of widespread international travel and the increased range of the mosquito vectors. US Army Special Operations Command (USASOC) personnel are at an increased risk of exposure to dengue based on their frequent deployments to and presence in dengue endemic areas worldwide. Repeated deployments to different endemic areas can increase the risk for developing the more serious sequelae of dengue: dengue hemorrhagic fever (DHF) and dengue shock syndrome (DSS). Information about the seroprevalence rate of dengue in USASOC personnel, in particular, is lacking and is critical to assessing the risk, tailoring preventive medicine countermeasures, leveraging field diagnostics, and maintaining mission capability. In the first part of a two-part project to assess baseline seroprevalence in USASOC units, a random, unit-stratified sample of 500 anonymous serum specimens from personnel assigned to the highest-risk units in USASOC were screened for dengue using a microneutralization assay. Of the 500 specimens screened, 56 (11.2%) of 500 had neutralizing titers (NT) (MN₅₀≥10) against at least one DENV serotype. Subsequent sample titration resulted in 48 (85.7%) of 56 of the samples with NT (MN₅₀≥10) against at least one dengue serotype for an overall dengue exposure rate of 9.6% (48 of 500). The second part of the ongoing project, started in 2012, was a multicenter, serosurveillance project using predeployment and postdeployment sera collected from USASOC personnel deployed to South and Central America, Africa, and Southeast Asia. Preliminary results show a 13.2% (55 of 414) seropositivity rate. The significance of these findings as they relate to personal risk and operational impact is discussed. 2014.

  9. Kinetic effects on the morphology and stability of the pressure-induced extended-solid of carbon monoxide

    NASA Astrophysics Data System (ADS)

    Dang, Nhan C.; Ciezak-Jenkins, Jennifer A.

    2018-04-01

    In this work, the dependence of the morphology and stability of the extended solid of carbon monoxide (CO) is correlated to the rate of transformation from the molecular CO to extended solid of CO using optical imaging, photoluminescence, Raman spectroscopy, and X-ray diffraction. The analyses show the rate and pressure of the transformation to be strongly controlled by catalytic effects, both chemical and optical. In a larger volume per reaction area, the transformation was found to require either a longer time at an elevated pressure or a higher pressure compared to a sample synthesized in a smaller volume per reaction area, leading to the conclusion that the transformation rate is slower for a sample in a larger volume per reaction area. A faster rate of transformation was also noted when the reaction area of a CO sample was catalyzed with H2SO4. Through variation of the volume per reaction area, pressure or the addition of catalysts, it was possible to control the rate of the phase transition and therefore the morphology. In general, the extended solid of CO synthesized with a faster rate showed a more ordered structure and increased metastability relative to the material formed with a slower compression rate.

  10. Variation in the annual unsatisfactory rates of selected pathogens and indicators in ready-to-eat food sampled from the point of sale or service in Wales, United Kingdom.

    PubMed

    Meldrum, R J; Garside, J; Mannion, P; Charles, D; Ellis, P

    2012-12-01

    The Welsh Food Microbiological Forum "shopping basket" survey is a long running, structured surveillance program examining ready-to-eat food randomly sampled from the point of sale or service in Wales, United Kingdom. The annual unsatisfactory rates for selected indicators and pathogens for 1998 through 2008 were examined. All the annual unsatisfactory rates for the selected pathogens were <0.5%, and no pattern with the annual rate was observed. There was also no discernible trend observed for the annual rates of Listeria spp. (not moncytogenes), with all rates <0.5%. However, there was a trend observed for Esherichia coli, with a decrease in rate between 1998 and 2003, rapid in the first few years, and then a gradual increase in rate up to 2008. It was concluded that there was no discernible pattern to the annual unsatisfactory rates for Listeria spp. (not monocytogenes), L. monocytogenes, Staphylococcus aureus, and Bacillus cereus, but that a definite trend had been observed for E. coli.

  11. Diversity Dynamics in Nymphalidae Butterflies: Effect of Phylogenetic Uncertainty on Diversification Rate Shift Estimates

    PubMed Central

    Peña, Carlos; Espeland, Marianne

    2015-01-01

    The species rich butterfly family Nymphalidae has been used to study evolutionary interactions between plants and insects. Theories of insect-hostplant dynamics predict accelerated diversification due to key innovations. In evolutionary biology, analysis of maximum credibility trees in the software MEDUSA (modelling evolutionary diversity using stepwise AIC) is a popular method for estimation of shifts in diversification rates. We investigated whether phylogenetic uncertainty can produce different results by extending the method across a random sample of trees from the posterior distribution of a Bayesian run. Using the MultiMEDUSA approach, we found that phylogenetic uncertainty greatly affects diversification rate estimates. Different trees produced diversification rates ranging from high values to almost zero for the same clade, and both significant rate increase and decrease in some clades. Only four out of 18 significant shifts found on the maximum clade credibility tree were consistent across most of the sampled trees. Among these, we found accelerated diversification for Ithomiini butterflies. We used the binary speciation and extinction model (BiSSE) and found that a hostplant shift to Solanaceae is correlated with increased net diversification rates in Ithomiini, congruent with the diffuse cospeciation hypothesis. Our results show that taking phylogenetic uncertainty into account when estimating net diversification rate shifts is of great importance, as very different results can be obtained when using the maximum clade credibility tree and other trees from the posterior distribution. PMID:25830910

  12. Diversity dynamics in Nymphalidae butterflies: effect of phylogenetic uncertainty on diversification rate shift estimates.

    PubMed

    Peña, Carlos; Espeland, Marianne

    2015-01-01

    The species rich butterfly family Nymphalidae has been used to study evolutionary interactions between plants and insects. Theories of insect-hostplant dynamics predict accelerated diversification due to key innovations. In evolutionary biology, analysis of maximum credibility trees in the software MEDUSA (modelling evolutionary diversity using stepwise AIC) is a popular method for estimation of shifts in diversification rates. We investigated whether phylogenetic uncertainty can produce different results by extending the method across a random sample of trees from the posterior distribution of a Bayesian run. Using the MultiMEDUSA approach, we found that phylogenetic uncertainty greatly affects diversification rate estimates. Different trees produced diversification rates ranging from high values to almost zero for the same clade, and both significant rate increase and decrease in some clades. Only four out of 18 significant shifts found on the maximum clade credibility tree were consistent across most of the sampled trees. Among these, we found accelerated diversification for Ithomiini butterflies. We used the binary speciation and extinction model (BiSSE) and found that a hostplant shift to Solanaceae is correlated with increased net diversification rates in Ithomiini, congruent with the diffuse cospeciation hypothesis. Our results show that taking phylogenetic uncertainty into account when estimating net diversification rate shifts is of great importance, as very different results can be obtained when using the maximum clade credibility tree and other trees from the posterior distribution.

  13. Temperature and Atomic Oxygen Effects on Helium Leak Rates of a Candidate Main Interface Seal

    NASA Technical Reports Server (NTRS)

    Penney, Nicholas; Wasowski, Janice L.; Daniels, Christopher C.

    2011-01-01

    Helium leak tests were completed to characterize the leak rate of a 54 in. diameter composite space docking seal design in support of the National Aeronautics and Space Administration s (NASA's) Low Impact Docking System (LIDS). The evaluated seal design was a candidate for the main interface seal on the LIDS, which would be compressed between two vehicles, while docked, to prevent the escape of breathable air from the vehicles and into the vacuum of space. Leak tests completed at nominal temperatures of -30, 20, and 50 C on untreated and atomic oxygen (AO) exposed test samples were examined to determine the influence of both test temperature and AO exposure on the performance of the composite seal assembly. Results obtained for untreated seal samples showed leak rates which increased with increased test temperature. This general trend was not observed in tests of the AO exposed specimens. Initial examination of collected test data suggested that AO exposure resulted in higher helium leak rates, however, further analysis showed that the differences observed in the 20 and 50 C tests between the untreated and AO exposed samples were within the experimental error of the test method. Lack of discernable trends in the test data prevented concrete conclusions about the effects of test temperature and AO exposure on helium leak rates of the candidate seal design from being drawn. To facilitate a comparison of the current test data with results from previous leak tests using air as the test fluid, helium leak rates were converted to air leak rates using standard conversion factors for viscous and molecular flow. Flow rates calculated using the viscous flow conversion factor were significantly higher than the experimental air leakage values, whereas values calculated using the molecular flow conversion factor were significantly lower than the experimentally obtained air leak rates. The difference in these sets of converted flow rates and their deviation from the experimentally obtained air leak rate data suggest that neither conversion factor can be used alone to accurately convert helium leak rates to equivalent air leak rates for the test seals evaluated in this study; other leak phenomena, including permeation, must also be considered.

  14. Plasma Protein Turnover Rates in Rats Using Stable Isotope Labeling, Global Proteomics, and Activity-Based Protein Profiling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Jordan Ned; Tyrrell, Kimberly J.; Hansen, Joshua R.

    Protein turnover is important for general health on cellular and organism scales providing a strategy to replace old, damaged, or dysfunctional proteins. Protein turnover also informs of biomarker kinetics, as a better understanding of synthesis and degradation of proteins increases the clinical utility of biomarkers. Here, turnover rates of plasma proteins in rats were measured in vivo using a pulse-chase stable isotope labeling experiment. During the pulse, rats (n=5) were fed 13C6-labeled lysine (“heavy”) feed for 23 days to label proteins. During the chase, feed was changed to an unlabeled equivalent feed (“light”), and blood was repeatedly sampled from ratsmore » over 10 time points for 28 days. Plasma samples were digested with trypsin, and analyzed with liquid chromatography-tandem mass spectrometry (LC-MS/MS). MaxQuant was used to identify peptides and proteins, and quantify heavy:light lysine ratios. A system of ordinary differential equations was used to calculate protein turnover rates. Using this approach, 273 proteins were identified, and turnover rates were quantified for 157 plasma proteins with half-lives ranging 0.3-103 days. For the ~70 most abundant proteins, variability in turnover rates among rats was low (median coefficient of variation: 0.09). Activity-based protein profiling was applied to pooled plasma samples to enrich serine hydrolases using a fluorophosphonate (FP2) activity-based probe. This enrichment resulted in turnover rates for an additional 17 proteins. This study is the first to measure global plasma protein turnover rates in rats in vivo, measure variability of protein turnover rates in any animal model, and utilize activity-based protein profiling for enhancing measurements of targeted, low-abundant proteins, such as those commonly used as biomarkers. Measured protein turnover rates will be important for understanding of the role of protein turnover in cellular and organism health as well as increasing the utility of protein biomarkers through better understanding of processes governing biomarker kinetics.« less

  15. [Effects of carrier liquid and flow rate on the separation in gravitational field-flow fractionation].

    PubMed

    Guo, Shuang; Zhu, Chenqi; Gao-Yang, Yaya; Qiu, Bailing; Wu, Di; Liang, Qihui; He, Jiayuan; Han, Nanyin

    2016-02-01

    Gravitational field-flow fractionation is the simplest field-flow fractionation technique in terms of principle and operation. The earth' s gravity is its external field. Different sized particles are injected into a thin channel and carried by carrier fluid. The different velocities of the carrier liquid in different places results in a size-based separation. A gravitational field-flow fractionation (GrFFF) instrument was designed and constructed. Two kinds of polystyrene (PS) particles with different sizes (20 µm and 6 µm) were chosen as model particles. In this work, the separation of the sample was achieved by changing the concentration of NaN3, the percentage of mixed surfactant in the carrier liquid and the flow rate of carrier liquid. Six levels were set for each factor. The effects of these three factors on the retention ratio (R) and plate height (H) of the PS particles were investigated. It was found that R increased and H decreased with increasing particle size. On the other hand, the R and H increased with increasing flow rate. The R and H also increased with increasing NaN3 concentration. The reason was that the electrostatic repulsive force between the particles and the glass channel wall increased. The force allowed the samples approach closer to the channel wall. The results showed that the resolution and retention time can be improved by adjusting the experimental conditions. These results can provide important values to the further applications of GrFFF technique.

  16. Annealed importance sampling with constant cooling rate

    NASA Astrophysics Data System (ADS)

    Giovannelli, Edoardo; Cardini, Gianni; Gellini, Cristina; Pietraperzia, Giangaetano; Chelli, Riccardo

    2015-02-01

    Annealed importance sampling is a simulation method devised by Neal [Stat. Comput. 11, 125 (2001)] to assign weights to configurations generated by simulated annealing trajectories. In particular, the equilibrium average of a generic physical quantity can be computed by a weighted average exploiting weights and estimates of this quantity associated to the final configurations of the annealed trajectories. Here, we review annealed importance sampling from the perspective of nonequilibrium path-ensemble averages [G. E. Crooks, Phys. Rev. E 61, 2361 (2000)]. The equivalence of Neal's and Crooks' treatments highlights the generality of the method, which goes beyond the mere thermal-based protocols. Furthermore, we show that a temperature schedule based on a constant cooling rate outperforms stepwise cooling schedules and that, for a given elapsed computer time, performances of annealed importance sampling are, in general, improved by increasing the number of intermediate temperatures.

  17. The effect of sampling rate and lowpass filters on saccades - A modeling approach.

    PubMed

    Mack, David J; Belfanti, Sandro; Schwarz, Urs

    2017-12-01

    The study of eye movements has become popular in many fields of science. However, using the preprocessed output of an eye tracker without scrutiny can lead to low-quality or even erroneous data. For example, the sampling rate of the eye tracker influences saccadic peak velocity, while inadequate filters fail to suppress noise or introduce artifacts. Despite previously published guiding values, most filter choices still seem motivated by a trial-and-error approach, and a thorough analysis of filter effects is missing. Therefore, we developed a simple and easy-to-use saccade model that incorporates measured amplitude-velocity main sequences and produces saccades with a similar frequency content to real saccades. We also derived a velocity divergence measure to rate deviations between velocity profiles. In total, we simulated 155 saccades ranging from 0.5° to 60° and subjected them to different sampling rates, noise compositions, and various filter settings. The final goal was to compile a list with the best filter settings for each of these conditions. Replicating previous findings, we observed reduced peak velocities at lower sampling rates. However, this effect was highly non-linear over amplitudes and increasingly stronger for smaller saccades. Interpolating the data to a higher sampling rate significantly reduced this effect. We hope that our model and the velocity divergence measure will be used to provide a quickly accessible ground truth without the need for recording and manually labeling saccades. The comprehensive list of filters allows one to choose the correct filter for analyzing saccade data without resorting to trial-and-error methods.

  18. Gender Inequity in Academia: An Empirical Analysis.

    ERIC Educational Resources Information Center

    Alpert, Dona

    1989-01-01

    Compared equity in number and salary between women and men at different ranks within a sample of doctoral-level institutions of higher education (N=109). Found that at current rate of increase it will take women 90 years to be equally represented and that gap in salaries has increased since 1975. (ABL)

  19. A graphical method for determining the dry-depositional component of aerosol samples and their field blanks

    NASA Astrophysics Data System (ADS)

    Huang, Suilou; Rahn, Kenneth A.; Arimoto, Richard

    During the Atmosphere/Ocean Chemistry Experiment (AEROCE), field blanks of certain elements in aerosol samples occasionally increased abruptly, always during periods of unusually high atmospheric concentrations. We hypothesized that the anomalous blanks were created by coarse aerosol entering the sampling shelters and depositing onto the blank filters. If so, samples taken nearby should have been similarly affected. To test this hypothesis, we developed a simple graphical method in which elemental masses in field blanks are plotted against elemental masses in pumped samples, and zones of proportionality between the two are sought. Data from Bermuda and Mace Head (coastal western Ireland) confirmed that depositional zones did indeed appear, but only for coarse-particle elements and only under certain conditions. Actual increases of crustal and pollution-derived elements agreed well with values predicted from settling velocities and sampling rates: blanks increased up to an order of magnitude or more but samples by less than 1%. Marine elements behaved like crustal elements in most samples but occasionally were much more enriched: blanks increased up to 30-fold and samples up to about 3%. It thus appears that when coarse-particle elements are present in high concentrations, their field blanks and samples may be measurably affected by dry deposition. Depending on the elements of interest, this dry deposition may have to be measured and the concentrations corrected.

  20. Quantifying Marine Emissions of Biogenic Volatile Organic Compounds Using Laboratory Measurements of Plankton Monocultures and Field Samples

    NASA Astrophysics Data System (ADS)

    Sabolis, A. W.; Meskhidze, N.; Kamykowski, D.; Reed, R. E.

    2010-12-01

    Marine biogenic volatile organic compounds (BVOCs) have been suggested to contribute significant portion of the organic carbon present in ocean atmosphere. In this study emission rates of 40 different hydrocarbons are quantified for lab-grown non-axenic phytoplankton monocultures and ambient samples from the Pamlico-Neuse Estuary, NC. The outcome of environmental conditions on production of BVOCs was examined for different light and temperature conditions. These different regimes are considered proxies for physiological stress-induced effects observed in natural ecosystems. The samples were incubated in a climate controlled room; they were then transferred to smaller volumes (200 ml) for analysis. BVOCs accumulated in the water and headspace above the water were measured by bubbling hydrocarbon-free gas mixture through the sample and passing the gas stream through a gas chromatography/mass spectrometry system equipped with a sample pre-concentrator. Inside the pre-concentrator, the compounds were trapped on a sorbent material, heated, and flushed into the GC-MS column. The pre-concentrator/GC-MS system gave at least 1000 times magnification of the sample concentrations, allowing detection of low ppt levels of hydrocarbons. Here we report results for lab-grown diatoms Thalassiosira weissflogii and Thalassiosira pseudonana, prymnesiophyte Pleurochrysis carterae, and dinoflagellates Karina brevis and Procentrum minimum, as well as field samples. To make results widely usable, all the emissions are normalized to Chlorophyll-a (Chl-a) concentration and cell counts. Our results show that diatoms had the highest isoprene production rate of 2.8 μmol (g Chl-a)-1 h-1 with ranges between 1.4 and 3.6 μmol (g Chl-a)-1 h-1 at light levels between 90 and 900 μE m-2 s-1, respectively. The prymnesiophyte and dinoflagellate species had isoprene production rates of 1.3±0.4 μmol (g Chl-a)-1 h-1 with a similar light dependency as diatoms. Field samples had comparable isoprene production rate of 3.5 μmol (g Chl-a)-1 h-1 with ranges between 0.6 and 4.1 μmol (g Chl-a)-1 h-1 for similar light levels and temperatures between 18 to 30°C. Three monoterpenes detected were α-pinene, camphene, and d-limonene. Diatoms had the highest α-pinene and d-limonene production rates of 0.045 μmol (g Chl-a)-1 h-1 and 0.015 μmol (g Chl-a)-1 h-1, respectively. The prymnesiophyte species had the highest camphene production of 0.021 μmol (g Chl-a)-1 h-1. Production rates of d-limonene and camphene did not show a well-defined light dependency, but both isoprene and α-pinene showed an increase in terpene production with increasing light intensities. Field samples show α-pinene, d-limonene, and camphene production rates of 0.05 μmol (g Chl-a)-1 h-1, 0.02 μmol (g Chl-a)-1 h-1 and 0.018 μmol (g Chl-a)-1 h-1, respectively. Field samples acclimated at 26°C had the highest terpene production rates. This study tabulates a large number of BVOC emission rates for various phytoplankton species under diverse environmental conditions.

  1. Estimation of Surface Heat Flux and Surface Temperature during Inverse Heat Conduction under Varying Spray Parameters and Sample Initial Temperature

    PubMed Central

    Aamir, Muhammad; Liao, Qiang; Zhu, Xun; Aqeel-ur-Rehman; Wang, Hong

    2014-01-01

    An experimental study was carried out to investigate the effects of inlet pressure, sample thickness, initial sample temperature, and temperature sensor location on the surface heat flux, surface temperature, and surface ultrafast cooling rate using stainless steel samples of diameter 27 mm and thickness (mm) 8.5, 13, 17.5, and 22, respectively. Inlet pressure was varied from 0.2 MPa to 1.8 MPa, while sample initial temperature varied from 600°C to 900°C. Beck's sequential function specification method was utilized to estimate surface heat flux and surface temperature. Inlet pressure has a positive effect on surface heat flux (SHF) within a critical value of pressure. Thickness of the sample affects the maximum achieved SHF negatively. Surface heat flux as high as 0.4024 MW/m2 was estimated for a thickness of 8.5 mm. Insulation effects of vapor film become apparent in the sample initial temperature range of 900°C causing reduction in surface heat flux and cooling rate of the sample. A sensor location near to quenched surface is found to be a better choice to visualize the effects of spray parameters on surface heat flux and surface temperature. Cooling rate showed a profound increase for an inlet pressure of 0.8 MPa. PMID:24977219

  2. Decontamination methods for samples preserved in cetylpyridinium chloride and cultured on thin-layer agar.

    PubMed

    Ardizzoni, E; Mulders, W; Sanchez-Padilla, E; Varaine, F; de Jong, B C; Rigouts, L

    2014-08-01

    Long transportation times of samples to culture laboratories can lead to higher contamination rates and significant loss of viability, resulting in lower culture positivity rates. Thin-layer agar (TLA) is a sensitive culture method for the isolation of Mycobacterium tuberculosis that has been optimised with N-acetyl-L-cysteine-sodium hydroxide (NALC-NaOH) decontaminated samples. The combination of the TLA culture method and other decontamination procedures has not been extensively validated. Among 390 smear-positive samples, we compared the culture positivity of samples decontaminated using the Petroff method vs. NALC-NaOH neutralised with phosphate buffer (PBS), applied to samples preserved with cetylpyridinium chloride (CPC) or CPC-free, and then of CPC-preserved samples decontaminated with NALC-NaOH neutralised using Difco neutralising buffer. The sediments were inoculated on TLA, and then on MGIT 960 or Löwenstein-Jensen (LJ) as gold standards. Decontamination with NALC-NaOH yielded higher culture positivity in TLA than in the Petroff method, which was further enhanced by neutralising CPC with the Difco buffer. Surprisingly, culture positivity on LJ also increased after using Difco buffer, suggesting that CPC may not be completely neutralised in egg-based medium. After transportation in CPC, decontamination using NALC-NaOH followed by neutralisation using Difco buffer resulted in the best recovery rates for samples inoculated on TLA and on LJ.

  3. Quality assessment of lymph node sampling in rhabdomyosarcoma: A surveillance, epidemiology, and end results (SEER) program study.

    PubMed

    Lobeck, Inna; Dupree, Phylicia; Karns, Rebekah; Rodeberg, David; von Allmen, Daniel; Dasgupta, Roshni

    2017-04-01

    Lymph node sampling is integral in the management of extremity and paratesticular rhabdomyosarcoma (RMS). The aim of this study was to determine overall surgical compliance with treatment protocols and impact of nodal sampling outcomes in these tumors. A query of the surveillance, epidemiology, and end results program (SEER) database was performed from 2003 to 2008 for patients <19years of age with RMS. Data obtained included demographics, five-year survival and rate of nodal sampling. Analysis was performed utilizing chi-squared, Kaplan-Meier and hazard ratio modeling. Of 537 patients with extremity RMS, nodal sampling was performed in 25.7% (n=138). This lack of nodal sampling had a negative outcome on survival (p=0.004). Sixty five patients with paratesticular RMS aged greater than 10 were identified and also displayed low rates of lymph node sampling (47.7%, n=31). For paratesticular patients, a similar increase in survival was seen in patients who underwent nodal evaluation (p=0.024). Lymph node sampling is the standard of care in RMS. However, surgical compliance with treatment protocols is poor. Nodal evaluation correlated significantly with overall survival. These findings suggest a need for improved education among surgeons and oncologists regarding the need lymph node assessment in pediatric oncology patients. Evidence rating/classification: Prognosis study, Level III. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Absorbance characteristics of a liquid-phase gas sensor based on gas-permeable liquid core waveguides.

    PubMed

    Peng, Pei; Wang, Wei; Zhang, Li; Su, Shiguang; Wang, Jiahui

    2013-12-04

    The absorbance characteristics and influential factors on these characteristics for a liquid-phase gas sensor, which is based on gas-permeable liquid core waveguides (LCWs), are studied from theoretical and experimental viewpoints in this paper. According to theory, it is predicted that absorbance is proportional to the analyte concentration, sampling time, analyte diffusion coefficient, and geometric factor of this device when the depletion layer of the analyte is ignored. The experimental results are in agreement with the theoretical hypothesis. According to the experimental results, absorbance is time-dependent and increasing linearly over time after the requisite response time with a linear correlation coefficient r(2)>0.999. In the linear region, the rate of absorbance change (RAC) indicates improved linearity with sample concentration and a relative higher sensitivity than instantaneous absorbance does. By using a core liquid that is more affinitive to the analyte, reducing wall thickness and the inner diameter of the tubing, or increasing sample flow rate limitedly, the response time can be decreased and the sensitivity can be increased. However, increasing the LCW length can only enhance sensitivity and has no effect on response time. For liquid phase detection, there is a maximum flow rate, and the absorbance will decrease beyond the stated limit. Under experimental conditions, hexane as the LCW core solvent, a tubing wall thickness of 0.1 mm, a length of 10 cm, and a flow rate of 12 mL min(-1), the detection results for the aqueous benzene sample demonstrate a response time of 4 min. Additionally, the standard curve for the RAC versus concentration is RAC=0.0267c+0.0351 (AU min(-1)), with r(2)=0.9922 within concentrations of 0.5-3.0 mg L(-1). The relative error for 0.5 mg L(-1) benzene (n=6) is 7.4±3.7%, and the LOD is 0.04 mg L(-1). This research can provide theoretical and practical guides for liquid-phase gas sensor design and development based on a gas-permeable Teflon AF 2400 LCW. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Optimization of a biomimetic bone cement: role of DCPD.

    PubMed

    Panzavolta, Silvia; Bracci, Barbara; Rubini, Katia; Bigi, Adriana

    2011-08-01

    We previously proposed a biomimetic α-tricalcium phosphate (α-TCP) bone cement where gelatin controls the transformation of α-TCP into calcium deficient hydroxyapatite (CDHA), leading to improved mechanical properties. In this study we investigated the setting and hardening processes of biomimetic cements containing increasing amounts of CaHPO(4)·2H2O (DCPD) (0, 2.5, 5, 10, 15 wt.%), with the aim to optimize composition. Both initial and final setting times increased significantly when DCPD content accounts for 10 wt.%, whereas cements containing 15 wt.% DCPD did not set at all. Differential scanning calorimetry (DSC), X-ray diffraction (XRD), thermogravimetry (TG) and scanning electron microscopy (SEM) investigations were performed on samples maintained in physiological solution for different times. DCPD dissolution starts soon after cement preparation, but the rate of transformation decreases on increasing DCPD initial content in the samples. The rate of α-TCP to CDHA conversion during hardening decreases on increasing DCPD initial content. Moreover, the presence of DCPD prevents gelatin release during hardening. The combined effects of gelatin and DCPD on the rate of CDHA formation and porosity lead to significantly improved mechanical properties, with the best composition displaying a compressive strength of 35 MPa and a Young modulus of 1600 MPa. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. The relationship of motor unit size, firing rate and force.

    PubMed

    Conwit, R A; Stashuk, D; Tracy, B; McHugh, M; Brown, W F; Metter, E J

    1999-07-01

    Using a clinical electromyographic (EMG) protocol, motor units were sampled from the quadriceps femoris during isometric contractions at fixed force levels to examine how average motor unit size and firing rate relate to force generation. Mean firing rates (mFRs) and sizes (mean surface-detected motor unit action potential (mS-MUAP) area) of samples of active motor units were assessed at various force levels in 79 subjects. MS-MUAP size increased linearly with increased force generation, while mFR remained relatively constant up to 30% of a maximal force and increased appreciably only at higher force levels. A relationship was found between muscle force and mS-MUAP area (r2 = 0.67), mFR (r2 = 0.38), and the product of mS-MUAP area and mFR (mS-MUAP x mFR) (r2 = 0.70). The results support the hypothesis that motor units are recruited in an orderly manner during forceful contractions, and that in large muscles only at higher levels of contraction ( > 30% MVC) do mFRs increase appreciably. MS-MUAP and mFR can be assessed using clinical EMG techniques and they may provide a physiological basis for analyzing the role of motor units during muscle force generation.

  7. Impact of the revised penicillin susceptibility breakpoints for Streptococcus pneumoniae on antimicrobial resistance rates of meningeal and non-meningeal pneumococcal strains.

    PubMed

    Al-Waili, Badria R; Al-Thawadi, Sahar; Hajjar, Sami Al

    2013-01-01

    In January 2008, the Clinical Laboratory Standard Institute (CLSI) revised the Streptococcus pneumoniae breakpoints for penicillin to define the susceptibility of meningeal and non-meningeal isolates. We studied the impact of these changes. In addition, the pneumococcal resistance rate to other antimicrobial agents was reviewed. Laboratory data on peumococcal isolates collected retrospectively from hospitalized children in tertiary care hospital in Riyadh, Saudi Arabia from January 2006 to March 2012. Only sterile samples were included from cerebrospinal fluids, blood, sterile body fluids and surgical tissue. Other samples such as sputum and non sterile samples were excluded. We included samples from children 14 years old or younger. The minimum inhibitory concentration (MIC) for penicillin, cefuroxime, ceftriaxone and meropenem were determined by using the E-test, while susceptibility to erythromycin, cotrimoxazole and vancomycin were measured using the disc diffusion methods following the guideline of CLSI. Specimens were analyzed in two different periods: from January 2006 to December 2007 and from January 2008 to March 2012. During the two periods there were 208 samples of which 203 were blood samples. Full penicillin resistance was detected in 6.6% in the first period. There was decrease in penicillin nonmeningeal resistance to 1.5% and an increase in resistance in penicillin meningeal 68.2% in the second period (P=.0001). There was an increase in rate of resistance among S pneumoniae isolates over the two periods to parenteral cefuroxime, erythromycin and cotrimoxazole by 34.6%, 35.5% and 51.9%, respectively. Total meropenem resistance found 4.3% and no vancomycin resistance was detected. The current study supports the use of the revised CLSI susceptibility breakpoints that promote using penicillin to treat nonmeningeal pneumococcal disease, and might slow the development of resistance to broader-spectrum antibiotics.

  8. Pattern-based integer sample motion search strategies in the context of HEVC

    NASA Astrophysics Data System (ADS)

    Maier, Georg; Bross, Benjamin; Grois, Dan; Marpe, Detlev; Schwarz, Heiko; Veltkamp, Remco C.; Wiegand, Thomas

    2015-09-01

    The H.265/MPEG-H High Efficiency Video Coding (HEVC) standard provides a significant increase in coding efficiency compared to its predecessor, the H.264/MPEG-4 Advanced Video Coding (AVC) standard, which however comes at the cost of a high computational burden for a compliant encoder. Motion estimation (ME), which is a part of the inter-picture prediction process, typically consumes a high amount of computational resources, while significantly increasing the coding efficiency. In spite of the fact that both H.265/MPEG-H HEVC and H.264/MPEG-4 AVC standards allow processing motion information on a fractional sample level, the motion search algorithms based on the integer sample level remain to be an integral part of ME. In this paper, a flexible integer sample ME framework is proposed, thereby allowing to trade off significant reduction of ME computation time versus coding efficiency penalty in terms of bit rate overhead. As a result, through extensive experimentation, an integer sample ME algorithm that provides a good trade-off is derived, incorporating a combination and optimization of known predictive, pattern-based and early termination techniques. The proposed ME framework is implemented on a basis of the HEVC Test Model (HM) reference software, further being compared to the state-of-the-art fast search algorithm, which is a native part of HM. It is observed that for high resolution sequences, the integer sample ME process can be speed-up by factors varying from 3.2 to 7.6, resulting in the bit-rate overhead of 1.5% and 0.6% for Random Access (RA) and Low Delay P (LDP) configurations, respectively. In addition, the similar speed-up is observed for sequences with mainly Computer-Generated Imagery (CGI) content while trading off the bit rate overhead of up to 5.2%.

  9. Inhibition of Sodium Benzoate on Stainless Steel in Tropical Seawater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seoh, S. Y.; Senin, H. B.; Nik, W. N. Wan

    2007-05-09

    The inhibition of sodium benzoate for stainless steel controlling corrosion was studied in seawater at room temperature. Three sets of sample have been immersed in seawater containing sodium benzoate with the concentrations of 0.3M, 0.6M and 1.0M respectively. One set of sample has been immersed in seawater without adding any sodium benzoate. It was found that the highest corrosion rate was observed for the stainless steel with no inhibitor was added to the seawater. As the concentration of sodium benzoate being increased, the corrosion rate is decreases. Results show that by the addition of 1.0M of sodium benzoate in seawatermore » samples, it giving {>=} 90% efficiencies.« less

  10. Surface Uplift Rate Constrained by Multiple Terrestrial Cosmogenic Nuclides: Theory and Application from the Central Andean Plateau

    NASA Astrophysics Data System (ADS)

    McPhillips, D. F.; Hoke, G. D.; Niedermann, S.; Wittmann, H.

    2015-12-01

    There is widespread interest in quantifying the growth and decay of topography. However, prominent methods for quantitative determinations of paleoelevation rely on assumptions that are often difficult to test. For example, stable isotope paleoaltimetry relies on the knowledge of past lapse rates and moisture sources. Here, we demonstrate how cosmogenic 10Be - 21Ne and/or 10Be - 26Al sample pairs can be applied to provide independent estimates of surface uplift rate using both published data and new data from the Atacama Desert. Our approach requires a priori knowledge of the maximum age of exposure of the sampled surface. Ignimbrite surfaces provide practical sampling targets. When erosion is very slow (roughly, ≤1 m/Ma), it is often possible to constrain paleo surface uplift rate with precision comparable to that of stable isotopic methods (approximately ±50%). The likelihood of a successful measurement is increased by taking n samples from a landscape surface and solving for one regional paleo surface uplift rate and n local erosion rates. In northern Chile, we solve for surface uplift and erosion rates using three sample groups from the literature (Kober et al., 2007). In the two lower elevation groups, we calculate surface uplift rates of 110 (+60/-12) m/Myr and 160 (+120/-6) m/Myr and estimate uncertainties with a bootstrap approach. The rates agree with independent estimates derived from stream profile analyses nearby (Hoke et al., 2007). Our calculated uplift rates correspond to total uplift of 1200 and 850 m, respectively, when integrated over appropriate timescales. Erosion rates were too high to reliably calculate the uplift rate in the third, high elevation group. New cosmogenic nuclide analyses from the Atacama Desert are in progress, and preliminary results are encouraging. In particular, a replicate sample in the vicinity of the first Kober et al. (2007) group independently yields a surface uplift rate of 110 m/Myr. Compared to stable isotope proxies, cosmogenic nuclides potentially provide better constraints on surface uplift in places where assumptions about paleo-atmospheric conditions are hard to constrain and justify. F. S. Kober et al. (2007), Geomorphology, 83, 97-110. G. D. Hoke et al. (2007), Tectonics, 26, doi:10.1029/2006TC002082.

  11. Agricultural land use doubled sediment yield of western China's rivers

    NASA Astrophysics Data System (ADS)

    Schmidt, A. H.; Bierman, P. R.; Sosa-Gonzalez, V.; Neilson, T. B.; Rood, D. H.; Martin, J.; Hill, M.

    2017-12-01

    Land use changes, such as deforestation and agriculture, increase soil erosion rates on the scale of hillslopes and small drainage basins; however, the effects of these changes on the sediment load in larger rivers is poorly quantified, with a few studies scattered globally, and only 10 data points in the world's most populous nation, China. At 20 different sites in western China, we compare contemporary (1945-1987) fluvial sediment yield data collected daily over 4 to 26 years (median = 19 years) to long-term measures of erosion (sediment generation) based on new isotopic measurements of in situ 10Be in river sediments. We find that median sediment transport at these sites exceeds background sediment generation rates by a factor of two (from 0.13 to 5.79 times, median 1.85 times) and that contemporary sediment yield is statistically significantly different from long-term sediment yield (p < 0.05). Agricultural land use is directly and significantly proportional to the ratio of contemporary sediment yield to long term sediment generation rates (Spearman correlation coefficient rho = 0.52, p < 0.05). We support these findings by calculating erosion indices (following Brown et al., 1988), which compare the delivery of meteoric 10Be to each watershed with the export of meteoric 10Be bound to riverine sediment. Erosion indices are also directly and significantly proportional to agricultural land use (rho = 0.58, p < 0.05). We measured unsupported 210Pb and 137Cs in 130 detrital samples from throughout the region. We find that only 4 samples (those from high elevation, low relief watersheds) have detectable 137Cs and 31 samples have detectable unsupported 210Pb. The lack of 137Cs in most samples suggests high rates of erosion in the 1950s-1960s when 137Cs would have been delivered to the landscape. Detectable 210Pb in 25% of the watersheds suggests that in some areas erosion rates have slowed since that time allowing 210Pb to accumulate to measurable levels. Together, these data sets demonstrate that upstream agricultural land use has significantly increased sediment supply to rivers in western China, likely increasing turbidity and decreasing ecosystem services such as fisheries.

  12. Mental disorder and long-term risk of mortality: 41 years of follow-up of a population sample in Stockholm, Sweden.

    PubMed

    Lundin, A; Modig, K; Halldin, J; Carlsson, A C; Wändell, P; Theobald, H

    2016-08-01

    An increased mortality risk associated with mental disorder has been reported for patients, but there are few studies are based on random samples with interview-based psychiatric diagnoses. Part of the increased mortality for those with mental disorder may be attributable to worse somatic health or hazardous health behaviour - consequences of the disorder - but somatic health information is commonly lacking in psychiatric samples. This study aims to examine long-term mortality risk for psychiatric diagnoses in a general population sample and to assess mediation by somatic ill health and hazardous health behaviour. We used a double-phase stratified random sample of individuals aged 18-65 in Stockholm County 1970-1971 linked to vital records. First phase sample was 32 186 individuals screened with postal questionnaire and second phase was 1896 individuals (920 men and 976 women) that participated in a full-day examination (participation rate 88%). Baseline examination included both a semi-structured interview with a psychiatrist, with mental disorders set according to the 8th version of the International Classification of Disease (ICD-8), and clinical somatic examination, including measures of body composition (BMI), hypertension, fasting blood glucose, pulmonary function and self-reported tobacco smoking. Information on vital status was obtained from the Total Population Register for the years 1970-2011. Associations with mortality were studied with Cox proportional hazard analyses. A total of 883 deaths occurred among the participants during the 41-year follow-up. Increased mortality rates were found for ICD-8 functional psychoses (hazard ratio, HR = 2.22, 95% confidence interval (95% CI): 1.15-4.30); psycho-organic symptoms (HR = 1.94, 95% CI: 1.31-2.87); depressive neuroses (HR = 1.71, 95% CI: 1.23-2.39); alcohol use disorder (HR = 1.91, 95% CI: 1.40-2.61); drug dependence (HR = 3.71, 95% CI: 1.80-7.65) and psychopathy (HR = 2.88, 95% CI: 1.02-8.16). Non-participants (n = 349) had mortality rates similar to participants (HR = 0.98, 95% CI: 0.81-1.18). In subgroup analyses of those with psychoses, depression or alcohol use disorder, adjusting for the potential mediators smoking and pulmonary function, showed only slight changes in the HRs. This study confirms the increased risk of mortality for several psychiatric diagnoses in follow-up studies on American, Finnish and Swedish population-based samples. Only a small part of the increased mortality hazard was attributable to differences in somatic health or hazardous health behaviour measured at baseline.

  13. Effect of heating rate on thermoluminescence output of LiF: Mg, Ti (TLD-100) in dosimetric applications

    NASA Astrophysics Data System (ADS)

    Singh, Ranjit; Kainth, Harpreet Singh

    2018-07-01

    The luminiscence characteristics of thermoluminscence dosimeter LiF: Mg, Ti (TLD-100) irradiated to X-rays from 6 MV linac have been studied for wide range of 2-50 K/s readout linear heating rates. The reproducibility of glow curves for TLDs is found to be better at lower heating rates and depreciate at higher heating rates. The glow curve spectra were analysed using deconvolution procedure based on general-order kinetics. Shift in the peak maximum temperature per unit rise in heating rate for various peaks were found to decrease with heating rate. The TLDs irradiated with same dose exhibit decreasing TL counts with increase in the heating rate, which indicate the thermal quenching effect in TLD-100. The value of activation energy for each peak within the glow curve increases with heating rate. Calibration curves plotted for the dose range 0.4-1020 cGy exhibit decreasing slope with increasing readout heating rate. Corrections for temperature lag between the heating element and the dosimeter, and the effective heating rate (βeff) across the sample estimated using formulation proposed by Kitis and Tuyn and are found to be fairly applicable.

  14. A time-varying effect model for examining group differences in trajectories of zero-inflated count outcomes with applications in substance abuse research.

    PubMed

    Yang, Songshan; Cranford, James A; Jester, Jennifer M; Li, Runze; Zucker, Robert A; Buu, Anne

    2017-02-28

    This study proposes a time-varying effect model for examining group differences in trajectories of zero-inflated count outcomes. The motivating example demonstrates that this zero-inflated Poisson model allows investigators to study group differences in different aspects of substance use (e.g., the probability of abstinence and the quantity of alcohol use) simultaneously. The simulation study shows that the accuracy of estimation of trajectory functions improves as the sample size increases; the accuracy under equal group sizes is only higher when the sample size is small (100). In terms of the performance of the hypothesis testing, the type I error rates are close to their corresponding significance levels under all settings. Furthermore, the power increases as the alternative hypothesis deviates more from the null hypothesis, and the rate of this increasing trend is higher when the sample size is larger. Moreover, the hypothesis test for the group difference in the zero component tends to be less powerful than the test for the group difference in the Poisson component. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  15. The effect of light soaking on crystalline silicon surface passivation by atomic layer deposited Al2O3

    NASA Astrophysics Data System (ADS)

    Liao, Baochen; Stangl, Rolf; Mueller, Thomas; Lin, Fen; Bhatia, Charanjit S.; Hoex, Bram

    2013-01-01

    The effect of light soaking of crystalline silicon wafer lifetime samples surface passivated by thermal atomic layer deposited (ALD) Al2O3 is investigated in this paper. Contrary to other passivation materials used in solar cell applications (i.e., SiO2, SiNx), using thermal ALD Al2O3, an increase in effective carrier lifetime after light soaking under standard testing conditions is observed for both p-type (˜45%) and n-type (˜60%) FZ c-Si lifetime samples. After light soaking and storing the samples in a dark and dry environment, the effective lifetime decreases again and practically returns to the value before light soaking. The rate of lifetime decrease after light soaking is significantly slower than the rate of lifetime increase by light soaking. To investigate the underlying mechanism, corona charge experiments are carried out on p-type c-Si samples before and after light soaking. The results indicate that the negative fixed charge density Qf present in the Al2O3 films increases due to the light soaking, which results in an improved field-effect passivation. Numerical calculations also confirm that the improved field-effect passivation is the main contributor for the increased effective lifetime after light soaking. To further understand the light soaking phenomenon, a kinetic model—a charge trapping/de-trapping model—is proposed to explain the time dependent behavior of the lifetime increase/decrease observed under/after light soaking. The trap model fits the experimental results very well. The observed light enhanced passivation for ALD Al2O3 passivated c-Si is of technological relevance, because solar cell devices operate under illumination, thus an increase in solar cell efficiency due to light soaking can be expected.

  16. Optically-synchronized encoder and multiplexer scheme for interleaved photonics analog-to-digital conversion

    NASA Astrophysics Data System (ADS)

    Villa, Carlos; Kumavor, Patrick; Donkor, Eric

    2008-04-01

    Photonics Analog-to-Digital Converters (ADCs) utilize a train of optical pulses to sample an electrical input waveform applied to an electrooptic modulator or a reverse biased photodiode. In the former, the resulting train of amplitude-modulated optical pulses is detected (converter to electrical) and quantized using a conversional electronics ADC- as at present there are no practical, cost-effective optical quantizers available with performance that rival electronic quantizers. In the latter, the electrical samples are directly quantized by the electronics ADC. In both cases however, the sampling rate is limited by the speed with which the electronics ADC can quantize the electrical samples. One way to increase the sampling rate by a factor N is by using the time-interleaved technique which consists of a parallel array of N electrical ADC converters, which have the same sampling rate but different sampling phase. Each operating at a quantization rate of fs/N where fs is the aggregated sampling rate. In a system with no real-time operation, the N channels digital outputs are stored in memory, and then aggregated (multiplexed) to obtain the digital representation of the analog input waveform. Alternatively, for real-time operation systems the reduction of storing time in the multiplexing process is desired to improve the time response of the ADC. The complete elimination of memories come expenses of concurrent timing and synchronization in the aggregation of the digital signal that became critical for a good digital representation of the analog signal waveform. In this paper we propose and demonstrate a novel optically synchronized encoder and multiplexer scheme for interleaved photonics ADCs that utilize the N optical signals used to sample different phases of an analog input signal to synchronize the multiplexing of the resulting N digital output channels in a single digital output port. As a proof of concept, four 320 Megasamples/sec 12-bit of resolution digital signals were multiplexed to form an aggregated 1.28 Gigasamples/sec single digital output signal.

  17. Influence of soil moisture on soil respiration

    NASA Astrophysics Data System (ADS)

    Fer, Miroslav; Kodesova, Radka; Nikodem, Antonin; Klement, Ales; Jelenova, Klara

    2015-04-01

    The aim of this work was to describe an impact of soil moisture on soil respiration. Study was performed on soil samples from morphologically diverse study site in loess region of Southern Moravia, Czech Republic. The original soil type is Haplic Chernozem, which was due to erosion changed into Regosol (steep parts) and Colluvial soil (base slope and the tributary valley). Soil samples were collected from topsoils at 5 points of the selected elevation transect and also from the parent material (loess). Grab soil samples, undisturbed soil samples (small - 100 cm3, and large - 713 cm3) and undisturbed soil blocks were taken. Basic soil properties were determined on grab soil samples. Small undisturbed soil samples were used to determine the soil water retention curves and the hydraulic conductivity functions using the multiple outflow tests in Tempe cells and a numerical inversion with HYDRUS 1-D. During experiments performed in greenhouse dry large undisturbed soil samples were wetted from below using a kaolin tank and cumulative water inflow due to capillary rise was measured. Simultaneously net CO2 exchange rate and net H2O exchange rate were measured using LCi-SD portable photosynthesis system with Soil Respiration Chamber. Numerical inversion of the measured cumulative capillary rise data using the HYDRUS-1D program was applied to modify selected soil hydraulic parameters for particular conditions and to simulate actual soil water distribution within each soil column in selected times. Undisturbed soil blocks were used to prepare thin soil sections to study soil-pore structure. Results for all soil samples showed that at the beginning of soil samples wetting the CO2 emission increased because of improving condition for microbes' activity. The maximum values were reached for soil column average soil water content between 0.10 and 0.15 cm3/cm3. Next CO2 emission decreased since the pore system starts filling by water (i.e. aggravated conditions for microbes, closing soil gas pathways etc.). In the case of H2O exchange rate, values increased with increasing soil water contents (up to 0.15-0.20 cm3/cm3) and then remained approximately constant. Acknowledgement: Authors acknowledge the financial support of the Ministry of Agriculture of the Czech Republic No. QJ1230319

  18. Growth rates of young-of-year shovelnose sturgeon in the Upper Missouri River

    USGS Publications Warehouse

    Braaten, P. J.; Fuller, D.B.

    2007-01-01

    Information on growth during the larval and young-of-year life stages in natural river environments is generally lacking for most sturgeon species. In this study, methods for estimating ages and quantifying growth were developed for field-sampled larval and young-of-year shovelnose sturgeon Scaphirhynchus platorynchus in the upper Missouri River. First, growth was assessed by partitioning samples of young-of-year shovelnose sturgeon into cohorts, and regressing weekly increases in cohort mean length on sampling date. This method quantified relative growth because ages of the cohorts were unknown. Cohort increases in mean length among sampling dates were positively related (P < 0.05, r2 > 0.59 for all cohorts) to sampling date, and yielded growth rate estimates of 0.80–2.95 mm day−1 (2003) and 0.44–2.28 mm day−1 (2004). Highest growth rates occurred in the largest (and earliest spawned) cohorts. Second, a method was developed to estimate cohort hatch dates, thus age on date of sampling could be determined. This method included quantification of post-hatch length increases as a function of water temperature (growth capacity; mm per thermal unit, mm TU−1), and summation of mean daily water temperatures to achieve the required number of thermal units that corresponded to post-hatch lengths of shovelnose sturgeon on sampling dates. For six of seven cohorts of shovelnose sturgeon analyzed, linear growth models (r2 ≥ 0.65, P < 0.0001) or Gompertz growth models (r2 ≥ 0.83, P < 0.0001) quantified length-at-age from hatch through 55 days post-hatch (98–100 mm). Comparisons of length-at-age derived from the growth models indicated that length-at-age was greater for the earlier-hatched cohorts than later-hatched cohorts. Estimated hatch dates for different cohorts were corroborated based on the dates that newly-hatched larval shovelnose sturgeon were sampled in the drift. These results provide the first quantification of growth dynamics for field-sampled age-0 shovelnose sturgeon in a natural river environment, and provide an accurate method for estimating age of wild-caught individuals. Methods of age determination used in this study have applications to sturgeons in other regions, but require additional testing and validation.

  19. Effects of pH, Temperature, Dissolved Oxygen, and Flow Rate on Phosphorus Release Processes at the Sediment and Water Interface in Storm Sewer

    PubMed Central

    Li, Haiyan; Li, Mingyi; Zhang, Xiaoran

    2013-01-01

    The effects of pH, temperature, dissolved oxygen (DO), and flow rate on the phosphorus (P) release processes at the sediment and water interface in rainwater pipes were investigated. The sampling was conducted in a residential storm sewer of North Li Shi Road in Xi Cheng District of Beijing on August 3, 2011. The release rate of P increased with the increase of pH from 8 to 10. High temperature is favorable for the release of P. The concentration of total phosphorus (TP) in the overlying water increased as the concentration of DO decreased. With the increase of flow rate from 0.7 m s−1 to 1.1 m s−1, the concentration of TP in the overlying water increased and then tends to be stable. Among all the factors examined in the present study, the flow rate is the primary influence factor on P release. The cumulative amount of P release increased with the process of pipeline runoff in the rainfall events with high intensities and shorter durations. Feasible measures such as best management practices and low-impact development can be conducted to control the P release on urban sediments by slowing down the flow rate. PMID:24349823

  20. Influence of the kind of peat and the depth of sampling on the biochemical properties of Tagan peatland

    NASA Astrophysics Data System (ADS)

    Wojciech Szajdak, Lech; Inisheva, Lydia I.

    2010-05-01

    The upper layer of a peat bog in which organic matter decomposes aerobically much more rapidly than in the underlying, anaerobic catotelm. As litter accumulates at the surface the size of the catotelm increases, because the thickness of the acrotelm is limited to depth at which aerobic respiration can occur. Although the rate of decomposition per unit volume of material is much greater in the acrotelm than in the catotelm, a point is reached at which the difference in volume between the two layers is such that the total rate of decomposition in the catotelm is equal to that in the acrotelm. This limits the thickness to which the bog can grow. Should there be a climate change (e.g. an increase in precipitation) growth can resume. Bogs therefore preserve a record of climatic conditions. Soils samples were taken from four places marked as No 1, 2, 3 and 4 each from two depth 0-25 and 50-75 cm of the peatland Tagan. Peatlands Tagan is located near Tomsk, West Siberia, Russia. Place No 1 in both layers represents grasses peat with the degree of the decomposition ranged from 25 to 35% (pH 6.31-7.95). Point 2 is characterized by wooden and wooden grasses peat with 35% degree of the decomposition (pH 5.16-9.31. There is buckbean peat in the points 3 and 4 (pH 6.4-6.49). However, 1.5 m depth of sapropel is located in point 4. The activity of the following enzymes: xanthine oxidase, phenolic oxidase, peroxidase, urease, nitrate reductase were measured and two forms of organic carbon (total organic carbon and dissolved organic carbon) and two form of iron Fe(II) and Fe(III) were determined in these samples. These enzymes participate in several biochemical pathways in soil connected with redox potential. The concentrations of indole-3-acetic acid, very famous fitohormone were also measured. It was observed in all places of sampling significant increase of the total organic carbon with an increase of the depth. However, the quantity of dissolved organic carbon closely decreased with an increase of the depth, suggesting lower microbiological activity of this level. The increase of the ratios Fe(II)/Fe(III) for place 1 and 2 and 4 and both depth 0-25 were similar (0.56; 0.59 and 0.65) indicating similar redox properties of these levels. Higher contents of F(III) were determined in upper layer than in lower layer of all samples. It indicate higher oxidizing properties upper layer than lower one The activity of nitrate reductase, peroxidase, phenolic axidase and xanthine oxidase agree with the content of two forms of iron in samples from all depth. In all samples was observed the decrease of the activity of urease with an increase of the depth. It suggest higher rate of the degradation process of urea created from the decomposition of peptides in peat. In sample No 1 the concentrations of indole-3-acetic acid very famous phytohormone were similar in both determined levels. However for sample No 2, 3 and 4 the significant decrease of the concentrations of indole-3-acetic acid with and increase of the depth of sampling was observed. Acknowledgements: This work was supported by a grant No. N N305 3204 36 founded by Polish Ministry of Education and by RFFR (No.No. 09-05-00235, 09-05-00395), Minister of Education and Science (No. 02.740.11.0325).

  1. Methods for Measuring Specific Rates of Mercury Methylation and Degradation and Their Use in Determining Factors Controlling Net Rates of Mercury Methylation

    PubMed Central

    Ramlal, Patricia S.; Rudd, John W. M.; Hecky, Robert E.

    1986-01-01

    A method was developed to estimate specific rates of demethylation of methyl mercury in aquatic samples by measuring the volatile 14C end products of 14CH3HgI demethylation. This method was used in conjunction with a 203Hg2+ radiochemical method which determines specific rates of mercury methylation. Together, these methods enabled us to examine some factors controlling the net rate of mercury methylation. The methodologies were field tested, using lake sediment samples from a recently flooded reservoir in the Southern Indian Lake system which had developed a mercury contamination problem in fish. Ratios of the specific rates of methylation/demethylation were calculated. The highest ratios of methylation/demethylation were calculated. The highest ratios of methylation/demethylation occurred in the flooded shorelines of Southern Indian Lake. These results provide an explanation for the observed increases in the methyl mercury concentrations in fish after flooding. PMID:16346959

  2. Outbreak or illusion: consequences of 'improved' diagnostics for gonorrhoea.

    PubMed

    Bennett, Amy; Jeffery, Katie; O'Neill, Eunan; Sherrard, Jackie

    2017-06-01

    The sexual health service in Oxford introduced gonorrhoea nucleic amplification acid testing using the BD Viper XTR™ System. For practical reasons, a confirmatory nucleic amplification acid testing using a different platform was not used initially. Following the introduction of nucleic amplification acid testing, the rates of gonorrhoea increased threefold. Concerns were raised that this increase represented an outbreak. A retrospective review of cases over six months suggested that there may have been a number of false-positive results. A prospective study was then undertaken over six months, where all gonorrhoea positive samples were sent for confirmatory testing. This evaluation of all gonorrhoea cases in an English county found that the overall presumptive false-positive rates for gonorrhoea nucleic amplification acid testing using BD Viper XTR™ in our population are significant at 27% of female samples, 13.2% of heterosexual male samples, 3.5% of anogenital multiple site men who have sex with men samples and 62.8% of pharyngeal only men who have sex with men samples. The data demonstrate the need for confirmatory testing using a second nucleic acid target, as per BASHH/Public Health England guidelines, especially in low-prevalence settings and extragenital sites, due to cross-reactivity with commensal Neisseria species and low positive predictive values.

  3. Towards a social functional account of laughter: Acoustic features convey reward, affiliation, and dominance.

    PubMed

    Wood, Adrienne; Martin, Jared; Niedenthal, Paula

    2017-01-01

    Recent work has identified the physical features of smiles that accomplish three tasks fundamental to human social living: rewarding behavior, establishing and managing affiliative bonds, and negotiating social status. The current work extends the social functional account to laughter. Participants (N = 762) rated the degree to which reward, affiliation, or dominance (between-subjects) was conveyed by 400 laughter samples acquired from a commercial sound effects website. Inclusion of a fourth rating dimension, spontaneity, allowed us to situate the current approach in the context of existing laughter research, which emphasizes the distinction between spontaneous and volitional laughter. We used 11 acoustic properties extracted from the laugh samples to predict participants' ratings. Actor sex moderated, and sometimes even reversed, the relation between acoustics and participants' judgments. Spontaneous laughter appears to serve the reward function in the current framework, as similar acoustic properties guided perceiver judgments of spontaneity and reward: reduced voicing and increased pitch, increased duration for female actors, and increased pitch slope, center of gravity, first formant, and noisiness for male actors. Affiliation ratings diverged from reward in their sex-dependent relationship to intensity and, for females, reduced pitch range and raised second formant. Dominance displayed the most distinct pattern of acoustic predictors, including increased pitch range, reduced second formant in females, and decreased pitch variability in males. We relate the current findings to existing findings on laughter and human and non-human vocalizations, concluding laughter can signal much more that felt or faked amusement.

  4. Towards a social functional account of laughter: Acoustic features convey reward, affiliation, and dominance

    PubMed Central

    Martin, Jared; Niedenthal, Paula

    2017-01-01

    Recent work has identified the physical features of smiles that accomplish three tasks fundamental to human social living: rewarding behavior, establishing and managing affiliative bonds, and negotiating social status. The current work extends the social functional account to laughter. Participants (N = 762) rated the degree to which reward, affiliation, or dominance (between-subjects) was conveyed by 400 laughter samples acquired from a commercial sound effects website. Inclusion of a fourth rating dimension, spontaneity, allowed us to situate the current approach in the context of existing laughter research, which emphasizes the distinction between spontaneous and volitional laughter. We used 11 acoustic properties extracted from the laugh samples to predict participants’ ratings. Actor sex moderated, and sometimes even reversed, the relation between acoustics and participants’ judgments. Spontaneous laughter appears to serve the reward function in the current framework, as similar acoustic properties guided perceiver judgments of spontaneity and reward: reduced voicing and increased pitch, increased duration for female actors, and increased pitch slope, center of gravity, first formant, and noisiness for male actors. Affiliation ratings diverged from reward in their sex-dependent relationship to intensity and, for females, reduced pitch range and raised second formant. Dominance displayed the most distinct pattern of acoustic predictors, including increased pitch range, reduced second formant in females, and decreased pitch variability in males. We relate the current findings to existing findings on laughter and human and non-human vocalizations, concluding laughter can signal much more that felt or faked amusement. PMID:28850589

  5. Mental Health Service Utilization before and after Receipt of a Service-Connected Disability Award for PTSD: Findings from a National Sample.

    PubMed

    Sripada, Rebecca K; Hannemann, Claire M; Schnurr, Paula P; Marx, Brian P; Pollack, Stacey J; McCarthy, John F

    2018-04-17

    To determine patterns of mental health service use before and after VA disability compensation awards for posttraumatic stress disorder (PTSD). A 10 percent random sample of VHA-enrolled Veterans with new or increased PTSD service connection between 2012 and 2014 (n = 22,249). We used latent trajectory analysis to identify utilization patterns and multinomial logistic regression to assess associations between Veteran characteristics and trajectory membership. We assessed receipt of VHA mental health encounters in each of the 52 weeks prior to and following PTSD disability rating or rating increase. The best fitting model had five groups: No Use (36.6 percent), Low Use (37.7 percent), Increasing Use (9.4 percent), Decreasing Use (11.2 percent), and High Use (5.1 percent). Adjusting for demographic characteristics and compared with the No Use group, Veterans in the other groups were more likely to reside closer to a VHA facility, receive a higher PTSD disability rating, and screen positive for military sexual trauma. Service use remained stable (80 percent) or increased (9 percent) for the vast majority of Veterans. Service utilization declined for only 11 percent. Data did not indicate substantial service discontinuation following rating. Low VHA service utilization suggests opportunities to enhance outreach for Veterans with PTSD-related disability benefits. © Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  6. The Role of Epilepsy and Epileptiform EEGs in Autism Spectrum Disorders

    PubMed Central

    Spence, Sarah J; Schneider, Mark T

    2009-01-01

    Autism is a neurodevelopmental disorder of unknown etiology characterized by social and communication deficits and the presence of restricted interests/repetitive behaviors. Higher rates of epilepsy have long been reported, but prevalence estimates vary from as little as 5% to as much as 46%. This variation is probably the result of sample characteristics that increase epilepsy risk such as sample ascertainment, lower IQ, the inclusion of patients with non-idiopathic autism, age, and gender. However, critical review of the literature reveals that the rate in idiopathic cases with normal IQ is still significantly above the population risk suggesting that autism itself is associated with an increased risk of epilepsy. Recently there has been interest in the occurrence of epileptiform electroencephalograms (EEGs) even in the absence of epilepsy. Rates as high as 60% have been reported and some investigators propose that these abnormalities may play a causal role in the autism phenotype. While this phenomenon is still not well understood and risk factors have yet to be determined, the treatment implications are increasingly important. We review the recent literature to elucidate possible risk factors for both epilepsy and epileptiform EEGs. We then review existing data and discuss controversies surrounding treatment of EEG abnormalities. PMID:19454962

  7. Survival and developmental disability in infants with birth weights of 501 to 800 grams, born between 1979 and 1994.

    PubMed

    O'Shea, T M; Klinepeter, K L; Goldstein, D J; Jackson, B W; Dillard, R G

    1997-12-01

    Because the survival rate has increased for extremely low birth weight neonates, many have raised the concern that the rate of developmental disability among survivors will also increase. To address this concern, we analyzed changes over time in survival and major neurosensory impairment in a sample of extremely low birth weight infants born between July 1, 1979, and June 30, 1994. The study sample included 513 infants with birth weights of 501 to 800 g who were cared for in either of the two neonatal intensive care units that serve a 17-county region in northwest North Carolina and who were born to mothers residing in that region. At 1 year of age (corrected for gestation), survivors were examined by a pediatrician and were tested using the Bayley Scales of Infant Development. Major neurosensory impairment was defined as cerebral palsy, a Bayley Mental Developmental Index <68, or blindness. A total of 209/216 (97%) of survivors were examined at 1 year of age. Epoch of birth was defined as follows: epoch 1, July 1, 1979 to June 30, 1984; epoch 2, July 1, 1984 to June 30, 1989; and epoch 3, July 1, 1989 to June 30, 1994. Survival rates for epochs 1, 2, and 3 were, respectively, 24/120 (20%), 63/175 (36%), and 129/218 (59%). In contrast, the proportions with a major neurosensory impairment did not increase over time; rates for successive epochs were 6/24 (25%), 17/61 (28%), and 26/124 (21%). Rates of cerebral palsy were 3/24 (13%), 12/61 (20%), and 9/124 (7%); rates of delayed mental development were 4/24 (17%), 12/61 (20%), and 17/124 (14%); and rates of blindness were 2/24 (8%), 0/62, and 5/124 (4%), respectively. This analysis suggests that the increasing survival of extremely low birth weight neonates since the late 1970s has not resulted in an increased rate of major developmental problems identifiable at 1 year of age.

  8. Role of Substrate on Quartz Cementation in Quartz Aggregates

    NASA Astrophysics Data System (ADS)

    Farver, J. R.; Winslow, D.; Onasch, C.

    2010-12-01

    Quartz cementation in quartz aggregates has been experimentally investigated. The starting material was disaggregated detrital quartz grains from the well-sorted, mature St. Peter Sandstone. The ‘as-is’ grains have patches of iron oxide coatings and some have euhedral overgrowths that contain iron oxide dust rims. In addition a set of experiments was run using grains that were cleaned by soaking in sodium hydrosulfite and sodium bisulfate solutions to remove exposed iron oxide coatings. Experimental charges consisted of amorphous silica powder (≈30 mg) to provide a source of silica for the quartz cement, AlCl3 powder (≈3 mg) to provide a tracer for Cathodoluminescence (CL) identification of cement formed during the experiment, 25 wt% NaCl brine solution (≈25 mg) to increase the silica solubility and to better mimic oil field brines, and the natural quartz grains (100-130 mg). The charges were weld-sealed in Au capsules and run in cold-seal pressure vessels at 250°C to 450°C at 150 MPa confining pressure for up to 8 weeks. After the experiments, the samples were vacuum impregnated with a low viscosity epoxy containing a blue dye. After curing, the sample charge was sawn in half along its long axis and one half was polished (to 1 micron diamond paste) for analysis. The nature and amount of quartz cement in the samples were determined by a combination of CL, light microscopy, and scanning electron microscopy. Photomosaics of the samples were created and the amount of cement, porosity, and average grain sizes were determined by point-counting. The cement formed during the experiment was easily recognized from the quartz grains (and previous overgrowths) by the difference in luminescence. The results indicate the amorphous silica powder provides a ready source for silica for quartz cementation due to its greater solubility than the quartz. The cementation rates are rapid (>14% cement formed in 2 weeks at 450°C and >7% in 8 weeks at 250°C). Compared to experiments using crushed fragments of synthetic quartz (Pepple, 2007), the amount of cement in these natural samples was greater. Cementation followed a common pattern in all samples. Microfractures, which formed during pressurization of the charges, healed very rapidly followed by overgrowths on the quartz grains. Cementation began closest to the amorphous silica, then progressed away. There was no measurable difference in the amount of quartz cement formed in samples of the as-is and cleaned St. Peter Sandstone indicating that iron played no role in the rate of cementation. Although the amount of cement formed increased with increasing temperature and duration of the experiments, the rate of cementation decreased dramatically in longer duration (8 weeks) experiments suggesting a change in the precipitation mechanism/rate. This apparent change in precipitation rate may reflect a decrease in available surfaces for nucleation and/or a decrease in growth rate as euhedral faces develop as proposed by Lander et al (2008).

  9. High Occurrence Rate and Contamination Level of Bacillus cereus in Organic Vegetables on Sale in Retail Markets.

    PubMed

    Kim, Young-Ji; Kim, Hong-Seok; Kim, Kwang-Yeop; Chon, Jung-Whan; Kim, Dong-Hyeon; Seo, Kun-Ho

    2016-12-01

    Organic foods have risen in popularity recently. However, the increased risk of bacterial contamination of organic foods has not been fully evaluated. In this study, 100 samples each of organic and conventional fresh vegetables (55 lettuce samples and 45 sprout samples) sold in South Korea were analyzed for aerobic bacteria, coliforms, Escherichia coli, and Bacillus cereus. Although the aerobic bacteria and coliform counts were not significantly different between the two farming types (p > 0.05), the occurrence rate of B. cereus was higher in organically cultivated vegetables compared with those grown conventionally (70% vs. 30%, respectively). The mean contamination level of B. cereus-positive organic samples was also significantly higher (1.86 log colony-forming unit [CFU]/g vs. 0.69 log CFU/g, respectively) (p < 0.05). In addition, six samples of organic vegetables were found to be contaminated with B. cereus at over 4 log CFU/g categorized as unsatisfactory according to Health Protection Agency guideline. The relatively higher occurrence rate of B. cereus in organic vegetables emphasizes the importance of implementing control measures in organic vegetable production and postharvest processing to reduce the risk of food poisoning.

  10. Accounting for sensor calibration, data validation, measurement and sampling uncertainties in monitoring urban drainage systems.

    PubMed

    Bertrand-Krajewski, J L; Bardin, J P; Mourad, M; Béranger, Y

    2003-01-01

    Assessing the functioning and the performance of urban drainage systems on both rainfall event and yearly time scales is usually based on online measurements of flow rates and on samples of influent effluent for some rainfall events per year. In order to draw pertinent scientific and operational conclusions from the measurement results, it is absolutely necessary to use appropriate methods and techniques in order to i) calibrate sensors and analytical methods, ii) validate raw data, iii) evaluate measurement uncertainties, iv) evaluate the number of rainfall events to sample per year in order to determine performance indicator with a given uncertainty. Based an previous work, the paper gives a synthetic review of required and techniques, and illustrates their application to storage and settling tanks. Experiments show that, controlled and careful experimental conditions, relative uncertainties are about 20% for flow rates in sewer pipes, 6-10% for volumes, 25-35% for TSS concentrations and loads, and 18-276% for TSS removal rates. In order to evaluate the annual pollutant interception efficiency of storage and settling tanks with a given uncertainty, efforts should first be devoted to decrease the sampling uncertainty by increasing the number of sampled events.

  11. Problems of stock definition in estimating relative contributions of Atlantic striped bass to the coastal fishery

    USGS Publications Warehouse

    Waldman, John R.; Fabrizio, Mary C.

    1994-01-01

    Stock contribution studies of mixed-stock fisheries rely on the application of classification algorithms to samples of unknown origin. Although the performance of these algorithms can be assessed, there are no guidelines regarding decisions about including minor stocks, pooling stocks into regional groups, or sampling discrete substocks to adequately characterize a stock. We examined these questions for striped bass Morone saxatilis of the U.S. Atlantic coast by applying linear discriminant functions to meristic and morphometric data from fish collected from spawning areas. Some of our samples were from the Hudson and Roanoke rivers and four tributaries of the Chesapeake Bay. We also collected fish of mixed-stock origin from the Atlantic Ocean near Montauk, New York. Inclusion of the minor stock from the Roanoke River in the classification algorithm decreased the correct-classification rate, whereas grouping of the Roanoke River and Chesapeake Bay stock into a regional (''southern'') group increased the overall resolution. The increased resolution was offset by our inability to obtain separate contribution estimates of the groups that were pooled. Although multivariate analysis of variance indicated significant differences among Chesapeake Bay substocks, increasing the number of substocks in the discriminant analysis decreased the overall correct-classification rate. Although the inclusion of one, two, three, or four substocks in the classification algorithm did not greatly affect the overall correct-classification rates, the specific combination of substocks significantly affected the relative contribution estimates derived from the mixed-stock sample. Future studies of this kind must balance the costs and benefits of including minor stocks and would profit from examination of the variation in discriminant characters among all Chesapeake Bay substocks.

  12. Colour Doppler and microbubble contrast agent ultrasonography do not improve cancer detection rate in transrectal systematic prostate biopsy sampling.

    PubMed

    Taverna, Gianluigi; Morandi, Giovanni; Seveso, Mauro; Giusti, Guido; Benetti, Alessio; Colombo, Piergiuseppe; Minuti, Francesco; Grizzi, Fabio; Graziotti, Pierpaolo

    2011-12-01

    What's known on the subject? and What does the study add? Transrectal gray-scale ultrasonography guided prostate biopsy sampling is the method for diagnosing prostate cancer (PC) in patients with an increased prostate specific antigen level and/or abnormal digital rectal examination. Several imaging strategies have been proposed to optimize the diagnostic value of biopsy sampling, although at the first biopsy nearly 10-30% of PC still remains undiagnosed. This study compares the PC detection rate when employing Colour Doppler ultransongraphy with or without the injection of SonoVue™ microbubble contrast agent, versus the transrectal ultrasongraphy-guided systematic biopsy sampling. The limited accuracy, sensitivity, specificity and the additional cost of using the contrast agent do not justify its routine application in PC detection. • To compare prostate cancer (PC) detection rate employing colour Doppler ultrasonography with or without SonoVue™ contrast agent with transrectal ultrasonography-guided systematic biopsy sampling. • A total of 300 patients with negative digital rectal examination and transrectal grey-scale ultrasonography, with PSA values ranging between 2.5 and 9.9 ng/mL, were randomized into three groups: 100 patients (group A) underwent transrectal ultrasonography-guided systematic bioptic sampling; 100 patients (group B) underwent colour Doppler ultrasonography, and 100 patients (group C) underwent colour Doppler ultrasonography before and during the injection of SonoVue™. • Contrast-enhanced targeted biopsies were sampled into hypervascularized areas of peripheral, transitional, apical or anterior prostate zones. • All the patients included in Groups B and C underwent a further 13 systematic prostate biopsies. The cancer detection rate was calculated for each group. • In 88 (29.3%) patients a histological diagnosis of PC was made, whereas 22 (7.4%) patients were diagnosed with high-grade prostatic intraepithelial neoplasia or atypical small acinar proliferation. • No significant differences were found among the three groups for cancer detection rate (P= 0.329). • Additionally, low sensitivity, specificity and accuracy of colour Doppler with or without SonoVue™ contrast agent were found. • Prostate cancer detection rate does not significantly improve with the use of colour Doppler ultrasonography with or without SonoVue™. • Although no collateral effects have been highlighted, the combined use of colour Doppler ultrasonography and SonoVue™ determines adjunctive costs and increases the mean time for taking a single prostate biopsy. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  13. Sexual assertiveness in heterosexually active men: a test of three samples.

    PubMed

    Noar, Seth M; Morokoff, Patricia J; Redding, Colleen A

    2002-08-01

    Heterosexually active men have great potential to increase condom use rates during sexual encounters. However, this potential cannot be realized if men are not assertive with their partners regarding condom use. This study reports on the examination of condom-specific sexual assertiveness (SA) in three independent samples of heterosexually active men. In so doing, a reliable and brief four-item measure of SA was developed from a measure previously used with women. Across all three samples, those with higher SA were significantly more likely to be further along the condom stages of change, and significantly less likely to have engaged in unprotected sex. Results suggest that SA is a meaningful construct for men and that increasing SA in men may result in subsequent increases in safer sexual behaviors.

  14. Biocide-mediated corrosion of coiled tubing.

    PubMed

    Sharma, Mohita; An, Dongshan; Liu, Tao; Pinnock, Tijan; Cheng, Frank; Voordouw, Gerrit

    2017-01-01

    Coiled tubing corrosion was investigated for 16 field water samples (S5 to S20) from a Canadian shale gas field. Weight loss corrosion rates of carbon steel beads incubated with these field water samples averaged 0.2 mm/yr, but injection water sample S19 had 1.25±0.07 mm/yr. S19 had a most probable number of zero acid-producing bacteria and incubation of S19 with carbon steel beads or coupons did not lead to big changes in microbial community composition. In contrast other field water samples had most probable numbers of APB of 102/mL to 107/mL and incubation of these field water samples with carbon steel beads or coupons often gave large changes in microbial community composition. HPLC analysis indicated that all field water samples had elevated concentrations of bromide (average 1.6 mM), which may be derived from bronopol, which was used as a biocide. S19 had the highest bromide concentration (4.2 mM) and was the only water sample with a high concentration of active bronopol (13.8 mM, 2760 ppm). Corrosion rates increased linearly with bronopol concentration, as determined by weight loss of carbon steel beads, for experiments with S19, with filtered S19 and with bronopol dissolved in defined medium. This indicated that the high corrosion rate found for S19 was due to its high bronopol concentration. The corrosion rate of coiled tubing coupons also increased linearly with bronopol concentration as determined by electrochemical methods. Profilometry measurements also showed formation of multiple pits on the surface of coiled tubing coupon with an average pit depth of 60 μm after 1 week of incubation with 1 mM bronopol. At the recommended dosage of 100 ppm the corrosiveness of bronopol towards carbon steel beads was modest (0.011 mm/yr). Higher concentrations, resulting if biocide is added repeatedly as commonly done in shale gas operations, are more corrosive and should be avoided. Overdosing may be avoided by assaying the presence of residual biocide by HPLC, rather than by assaying the presence of residual surviving bacteria.

  15. Biocide-mediated corrosion of coiled tubing

    PubMed Central

    An, Dongshan; Liu, Tao; Pinnock, Tijan; Cheng, Frank; Voordouw, Gerrit

    2017-01-01

    Coiled tubing corrosion was investigated for 16 field water samples (S5 to S20) from a Canadian shale gas field. Weight loss corrosion rates of carbon steel beads incubated with these field water samples averaged 0.2 mm/yr, but injection water sample S19 had 1.25±0.07 mm/yr. S19 had a most probable number of zero acid-producing bacteria and incubation of S19 with carbon steel beads or coupons did not lead to big changes in microbial community composition. In contrast other field water samples had most probable numbers of APB of 102/mL to 107/mL and incubation of these field water samples with carbon steel beads or coupons often gave large changes in microbial community composition. HPLC analysis indicated that all field water samples had elevated concentrations of bromide (average 1.6 mM), which may be derived from bronopol, which was used as a biocide. S19 had the highest bromide concentration (4.2 mM) and was the only water sample with a high concentration of active bronopol (13.8 mM, 2760 ppm). Corrosion rates increased linearly with bronopol concentration, as determined by weight loss of carbon steel beads, for experiments with S19, with filtered S19 and with bronopol dissolved in defined medium. This indicated that the high corrosion rate found for S19 was due to its high bronopol concentration. The corrosion rate of coiled tubing coupons also increased linearly with bronopol concentration as determined by electrochemical methods. Profilometry measurements also showed formation of multiple pits on the surface of coiled tubing coupon with an average pit depth of 60 μm after 1 week of incubation with 1 mM bronopol. At the recommended dosage of 100 ppm the corrosiveness of bronopol towards carbon steel beads was modest (0.011 mm/yr). Higher concentrations, resulting if biocide is added repeatedly as commonly done in shale gas operations, are more corrosive and should be avoided. Overdosing may be avoided by assaying the presence of residual biocide by HPLC, rather than by assaying the presence of residual surviving bacteria. PMID:28746397

  16. Monitoring landscape metrics by point sampling: accuracy in estimating Shannon's diversity and edge density.

    PubMed

    Ramezani, Habib; Holm, Sören; Allard, Anna; Ståhl, Göran

    2010-05-01

    Environmental monitoring of landscapes is of increasing interest. To quantify landscape patterns, a number of metrics are used, of which Shannon's diversity, edge length, and density are studied here. As an alternative to complete mapping, point sampling was applied to estimate the metrics for already mapped landscapes selected from the National Inventory of Landscapes in Sweden (NILS). Monte-Carlo simulation was applied to study the performance of different designs. Random and systematic samplings were applied for four sample sizes and five buffer widths. The latter feature was relevant for edge length, since length was estimated through the number of points falling in buffer areas around edges. In addition, two landscape complexities were tested by applying two classification schemes with seven or 20 land cover classes to the NILS data. As expected, the root mean square error (RMSE) of the estimators decreased with increasing sample size. The estimators of both metrics were slightly biased, but the bias of Shannon's diversity estimator was shown to decrease when sample size increased. In the edge length case, an increasing buffer width resulted in larger bias due to the increased impact of boundary conditions; this effect was shown to be independent of sample size. However, we also developed adjusted estimators that eliminate the bias of the edge length estimator. The rates of decrease of RMSE with increasing sample size and buffer width were quantified by a regression model. Finally, indicative cost-accuracy relationships were derived showing that point sampling could be a competitive alternative to complete wall-to-wall mapping.

  17. Biophysical constraints on leaf expansion in a tall conifer.

    PubMed

    Meinzer, Frederick C; Bond, Barbara J; Karanian, Jennifer A

    2008-02-01

    The physiological mechanisms responsible for reduced extension growth as trees increase in height remain elusive. We evaluated biophysical constraints on leaf expansion in old-growth Douglas-fir (Pseudotsuga menziesii (Mirb.) Franco) trees. Needle elongation rates, plastic and elastic extensibility, bulk leaf water (Psi(L)) and osmotic (Psi(pi)) potential, bulk tissue yield threshold and final needle length were characterized along a height gradient in crowns of > 50-m-tall trees during the period between bud break and full expansion (May to June). Although needle length decreased with increasing height, there was no height-related trend in leaf plastic extensibility, which was highest immediately after bud break (2.9%) and declined rapidly to a stable minimum value (0.3%) over a 3-week period during which leaf expansion was completed. There was a significant positive linear relationship between needle elongation rates and plastic extensibility. Yield thresholds were consistently lower at the upper and middle crown sampling heights. The mean yield threshold across all sampling heights was 0.12 +/- 0.03 MPa on June 8, rising to 0.34 +/- 0.03 MPa on June 15 and 0.45 +/- 0.05 MPa on June 24. Bulk leaf Psi(pi) decreased linearly with increasing height at a rate of 0.004 MPa m(-1) during the period of most rapid needle elongation, but the vertical osmotic gradient was not sufficient to fully compensate for the 0.015 MPa m(-1) vertical gradient in Psi(L), implying that bulk leaf turgor declined at a rate of about 0.011 MPa m(-1) increase in height. Although height-dependent reductions in turgor appeared to constrain leaf expansion, it is possible that the impact of reduced turgor was mitigated by delayed phenological development with increasing height, which resulted in an increase with height in the temperature during leaf expansion.

  18. Short Term INT-Formazan Production as a Proxy for Marine Prokaryote Respiration

    NASA Astrophysics Data System (ADS)

    Cajal-Medrano, R.; Villegas-Mendoza, J.; Maske, H.

    2016-02-01

    Prokaryotes are poisoned by the tetrazolium electron transport probe INT on time scales of less than one hour, invalidating the interpretation of the rate of in vivo INT reduction to formazan as a proxy for oxygen consumption rates (Villegas-Mendoza et al. 2015). We measured oxygen consumption rate (R; µM O2 hour-1) and electron transport activity with in vivo INT formazan production (IFP, mM formazan) at 0.5 mM INT during 1 hour exposure time of natural communities and cultures of the marine bacteria Vibrio harveyi growing in batch and continuous cultures. A strong exponential relationship R = 0.20 IFP2.15 (p<0.05) with oxygen consumption and total formazan production was found over a wide range of growth rates under aerobic condition. We find that IFP and oxygen consumption increase with bacterial specific growth rates and temperature as expected from basic principles of physiology and biochemistry. Oxygen and nitrogen saturated batch cultures of V. harveyi showed that both, IFP and oxygen consumption increased for 0.8 hours but then stopped similar to natural bacterial communities supporting the above relationship of IFP to prokaryote respiration. Our method implies adding 0.5 mM INT to a plankton sample and incubating for less than 1 hour. After prokaryote separation by size filtration (0.8 mm), the formazan crystals are collected by filtration (0.2 mm) and dissolved in propanol. The absorbance at 485 nm per sample volume yields the formazan potential that is related to prokaryote respiration in the sample.

  19. Measurement of elastic precursor decay in pre-heated aluminum films under ultra-fast laser generated shocks

    DOE PAGES

    Zuanetti, Bryan; McGrane, Shawn David; Bolme, Cynthia Anne; ...

    2018-05-18

    Here, this article presents results from laser-driven shock compression experiments performed on pre-heated pure aluminum films at temperatures ranging from 23 to 400 °C. The samples were vapor deposited on the surface of a 500 μm thick sapphire substrate and mounted onto a custom holder with an integrated ring-heater to enable variable initial temperature conditions. A chirped pulse amplified laser was used to generate a pulse for both shocking the films and for probing the free surface velocity using Ultrafast Dynamic Ellipsometry. The particle velocity traces measured at the free surface clearly show elastic and plastic wave separation, which wasmore » used to estimate the decay of the elastic precursor amplitude over propagation distances ranging from 0.278 to 4.595 μm. Elastic precursors (which also correspond to dynamic material strength under uniaxial strain) of increasing amplitudes were observed with increasing initial sample temperatures for all propagation distances, which is consistent with expectations for aluminum in a deformation regime where phonon drag limits the mobility of dislocations. The experimental results show peak elastic amplitudes corresponding to axial stresses of over 7.5 GPa; estimates for plastic strain-rates in the samples are of the order 10 9/s. The measured elastic amplitudes at the micron length scales are compared with those at the millimeter length-scales using a two-parameter model and used to correlate the rate sensitivity of the dynamic strength at strain-rates ranging from 10 3 to 10 9/s and elevated temperature conditions. The overall trend, as inferred from the experimental data, indicates that the temperature-strengthening effect decreases with increasing plastic strain-rates.« less

  20. Measurement of elastic precursor decay in pre-heated aluminum films under ultra-fast laser generated shocks

    NASA Astrophysics Data System (ADS)

    Zuanetti, Bryan; McGrane, Shawn D.; Bolme, Cynthia A.; Prakash, Vikas

    2018-05-01

    This article presents results from laser-driven shock compression experiments performed on pre-heated pure aluminum films at temperatures ranging from 23 to 400 °C. The samples were vapor deposited on the surface of a 500 μm thick sapphire substrate and mounted onto a custom holder with an integrated ring-heater to enable variable initial temperature conditions. A chirped pulse amplified laser was used to generate a pulse for both shocking the films and for probing the free surface velocity using Ultrafast Dynamic Ellipsometry. The particle velocity traces measured at the free surface clearly show elastic and plastic wave separation, which was used to estimate the decay of the elastic precursor amplitude over propagation distances ranging from 0.278 to 4.595 μm. Elastic precursors (which also correspond to dynamic material strength under uniaxial strain) of increasing amplitudes were observed with increasing initial sample temperatures for all propagation distances, which is consistent with expectations for aluminum in a deformation regime where phonon drag limits the mobility of dislocations. The experimental results show peak elastic amplitudes corresponding to axial stresses of over 7.5 GPa; estimates for plastic strain-rates in the samples are of the order 109/s. The measured elastic amplitudes at the micron length scales are compared with those at the millimeter length-scales using a two-parameter model and used to correlate the rate sensitivity of the dynamic strength at strain-rates ranging from 103 to 109/s and elevated temperature conditions. The overall trend, as inferred from the experimental data, indicates that the temperature-strengthening effect decreases with increasing plastic strain-rates.

  1. A randomized trial of survey participation in a national random sample of general practitioners and gynecologists in France.

    PubMed

    Legleye, S; Bohet, A; Razafindratsima, N; Bajos, N; Moreau, C

    2014-08-01

    Healthcare professionals play a critical role in women's choice of contraceptive methods. However, national surveys on sexual and reproductive health (SRH) among physicians are rare and present low participation rates. We conducted a randomized trial to test for the effectiveness of three interventions to improve survey participation of private physicians delivering reproductive health services in France. The study comprised a national random sample of 500 general practitioners and 500 gynecologists working in private offices. All received a postal invitation to participate either by completing a paper, phone or online questionnaire. Physicians were randomly assigned to six groups to test for the effect of three interventions: a non-monetary incentive in the form of a scientific book, telephone contact, and the possibility of completing the questionnaire by phone. Overall, 362 questionnaires were collected (26 online, 2 by phone) and 58 physicians were ineligible. The completion rate increased from 26.7% in physicians who received no intervention to 42.7% in those who received the book and a phone call. The phone call increased the completion rate by 11% percentage points (P=0.01), while the book had no significant effect. Results from multivariate logistic regressions also indicate that gynecologists (OR=1.6) and female physicians (OR=1.5) were more likely to participate than others. The results suggest that phone calls substantially increase participation of physicians in sexual and reproductive health surveys but have little impact on sampling distortion. Differentials in response rates by physicians' characteristics should be considered in future SRH studies among physicians. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  2. Measurement of elastic precursor decay in pre-heated aluminum films under ultra-fast laser generated shocks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zuanetti, Bryan; McGrane, Shawn David; Bolme, Cynthia Anne

    Here, this article presents results from laser-driven shock compression experiments performed on pre-heated pure aluminum films at temperatures ranging from 23 to 400 °C. The samples were vapor deposited on the surface of a 500 μm thick sapphire substrate and mounted onto a custom holder with an integrated ring-heater to enable variable initial temperature conditions. A chirped pulse amplified laser was used to generate a pulse for both shocking the films and for probing the free surface velocity using Ultrafast Dynamic Ellipsometry. The particle velocity traces measured at the free surface clearly show elastic and plastic wave separation, which wasmore » used to estimate the decay of the elastic precursor amplitude over propagation distances ranging from 0.278 to 4.595 μm. Elastic precursors (which also correspond to dynamic material strength under uniaxial strain) of increasing amplitudes were observed with increasing initial sample temperatures for all propagation distances, which is consistent with expectations for aluminum in a deformation regime where phonon drag limits the mobility of dislocations. The experimental results show peak elastic amplitudes corresponding to axial stresses of over 7.5 GPa; estimates for plastic strain-rates in the samples are of the order 10 9/s. The measured elastic amplitudes at the micron length scales are compared with those at the millimeter length-scales using a two-parameter model and used to correlate the rate sensitivity of the dynamic strength at strain-rates ranging from 10 3 to 10 9/s and elevated temperature conditions. The overall trend, as inferred from the experimental data, indicates that the temperature-strengthening effect decreases with increasing plastic strain-rates.« less

  3. Ultrasensitive SERS Flow Detector Using Hydrodynamic Focusing

    PubMed Central

    Negri, Pierre; Jacobs, Kevin T.; Dada, Oluwatosin O.; Schultz, Zachary D.

    2013-01-01

    Label-free, chemical specific detection in flow is important for high throughput characterization of analytes in applications such as flow injection analysis, electrophoresis, and chromatography. We have developed a surface-enhanced Raman scattering (SERS) flow detector capable of ultrasensitive optical detection on the millisecond time scale. The device employs hydrodynamic focusing to improve SERS detection in a flow channel where a sheath flow confines analyte molecules eluted from a fused silica capillary over a planar SERS-active substrate. Increased analyte interactions with the SERS substrate significantly improve detection sensitivity. The performance of this flow detector was investigated using a combination of finite element simulations, fluorescence imaging, and Raman experiments. Computational fluid dynamics based on finite element analysis was used to optimize the flow conditions. The modeling indicates that a number of factors, such as the capillary dimensions and the ratio of the sheath flow to analyte flow rates, are critical for obtaining optimal results. Sample confinement resulting from the flow dynamics was confirmed using wide-field fluorescence imaging of rhodamine 6G (R6G). Raman experiments at different sheath flow rates showed increased sensitivity compared with the modeling predictions, suggesting increased adsorption. Using a 50-millisecond acquisitions, a sheath flow rate of 180 μL/min, and a sample flow rate of 5 μL/min, a linear dynamic range from nanomolar to micromolar concentrations of R6G with a LOD of 1 nM is observed. At low analyte concentrations, rapid analyte desorption is observed, enabling repeated and high-throughput SERS detection. The flow detector offers substantial advantages over conventional SERS-based assays such as minimal sample volumes and high detection efficiency. PMID:24074461

  4. Atmospheric CO2 Records from Sites in the Atmospheric Environment Service Air Sampling Network (1975 and 1994)

    DOE Data Explorer

    Trivett, N. B.A. [Atmospheric Environment Service, Downsview, Ontario, Canada; Hudec, V. C. [Atmospheric Environment Service, Downsview, Ontario, Canada; Wong, C. S. [Marine Carbon Research Centre, Institute of Ocean Sciences, Sidney, British Columbia, Canada

    1997-01-01

    From the mid-1970s through the mid-1990s, air samples were collected for the purposes of monitoring atmospheric CO2 from four sites in the AES air sampling network. Air samples were collected approximately once per week, between 12:00 and 16:00 local time, in a pair of evacuated 2-L thick-wall borosilicate glass flasks. Samples were collected under preferred conditions of wind speed and direction (i.e., upwind of the main station and when winds are strong and steady). The flasks were evacuated to pressures of ~1 × 10-4 mbar or 0.01 Pa prior to being sent to the stations. The airwas not dried during sample collection. The flask data from Alert show an increase in the annual atmospheric CO2 concentration from 341.35 parts per million by volume (ppmv) in 1981 to 357.21 ppmv in 1991. For Cape St. James, Trivett and Higuchi (1989) reported that the mean annual rate of increase, obtained from the slope of a least-squares regression line through the annual averages, was 1.43 ppmv per year. In August 1992, the weather station at Cape St. James was automated; as a result, the flask sampling program was discontinued at this site. Estevan Point, on the West Coast of Vancouver Island, was chosen as a replacement station. Sampling at Estevan Point started in 1992; thus, the monthly and annual CO2record from Estevan Point is too short to show any long-term trends. The sampling site at Sable Island, off the coast of Nova Scotia, was established in 1975. The flask data from Sable Island show an increase in the annual atmospheric CO2 concentration from 334.49 parts per million by volume (ppmv) in 1977 (the first full year of data) to 356.02 ppmv in 1990. For Sable Island, Trivett and Higuchi (1989) reported that the mean annual rate of increase, obtained from the slope of a least-squares regression line through the annual averages, was 1.48 ppmv per year.

  5. Barriers to School Attendance and Gender Inequality: Empirical Evidence from a Sample of Ghanaian Schoolchildren

    ERIC Educational Resources Information Center

    Wolf, Sharon; McCoy, Dana C.; Godfrey, Erin B.

    2016-01-01

    Governments in sub-Saharan Africa have made marked efforts to increase school enrollment. Yet attendance and completion rates remain low, particularly for girls. This study examines the reasons that school children do not attend school in a sample of Ghanaian students. Girls were more likely to miss school because a family member was sick, whereas…

  6. The Danish National Health Survey 2010. Study design and respondent characteristics.

    PubMed

    Christensen, Anne Illemann; Ekholm, Ola; Glümer, Charlotte; Andreasen, Anne Helms; Hvidberg, Michael Falk; Kristensen, Peter Lund; Larsen, Finn Breinholt; Ortiz, Britta; Juel, Knud

    2012-06-01

    In 2010 the five Danish regions and the National Institute of Public Health at the University of Southern Denmark conducted a national representative health survey among the adult population in Denmark. This paper describes the study design and the sample and study population as well as the content of the questionnaire. The survey was based on five regional stratified random samples and one national random sample. The samples were mutually exclusive. A total of 298,550 individuals (16 years or older) were invited to participate. Information was collected using a mixed mode approach (paper and web questionnaires). A questionnaire with a minimum of 52 core questions was used in all six subsamples. Calibrated weights were computed in order to take account of the complex survey design and reduce non-response bias. In all, 177,639 individuals completed the questionnaire (59.5%). The response rate varied from 52.3% in the Capital Region of Denmark sample to 65.5% in the North Denmark Region sample. The response rate was particularly low among young men, unmarried people and among individuals with a different ethnic background than Danish. The survey was a result of extensive national cooperation across sectors, which makes it unique in its field of application, e.g. health surveillance, planning and prioritizing public health initiatives and research. However, the low response rate in some subgroups of the study population can pose problems in generalizing data, and efforts to increase the response rate will be important in the forthcoming surveys.

  7. Sensory Quality Preservation of Coated Walnuts.

    PubMed

    Grosso, Antonella L; Asensio, Claudia M; Grosso, Nelson R; Nepote, Valeria

    2017-01-01

    The objective of this study was to evaluate the sensory stability of coated walnuts during storage. Four walnut samples were prepared: uncoated (NC), and samples coated with carboxymethyl cellulose (NCMC), methyl cellulose (NMC), or whey protein (NPS). The samples were stored at room temperature for 210 d and were periodically removed from storage to perform a sensory descriptive analysis. A consumer acceptance test was carried out on the fresh product (storage day 0) to evaluate flavor. All samples exhibited significant differences in their sensory attributes initially and after storage. Intensity ratings for oxidized and cardboard flavors increased during storage. NC showed the highest oxidized and cardboard intensity ratings (39 and 22, respectively) and NMC exhibited the lowest intensity ratings for these negative attributes (8 and 17, respectively) after 210 d of storage. Alternatively, the intensity ratings for sweetness and walnut flavors were decreased for all samples. NMC had the lowest decrease at the end of storage for these positive attributes (75.86 in walnut flavor and 12.09 in sweetness). The results of this study suggest a protective effect of the use of an edible coating to preserve sensory attributes during storage, especially for samples coated with MC. The results of the acceptance test showed that addition of the coating negatively affected the flavor acceptance for NMC and NCMC coated walnuts. Edible coatings help to preserve sensory attributes in walnuts, improving their shelf-life, however, these coatings may affect consumer acceptance in some cases. © 2016 Institute of Food Technologists®.

  8. Aquatic passive sampling of perfluorinated chemicals with polar organic chemical integrative sampler and environmental factors affecting sampling rate.

    PubMed

    Li, Ying; Yang, Cunman; Bao, Yijun; Ma, Xueru; Lu, Guanghua; Li, Yi

    2016-08-01

    A modified polar organic chemical integrative sampler (POCIS) could provide a convenient way of monitoring perfluorinated chemicals (PFCs) in water. In the present study, the modified POCIS was calibrated to monitor PFCs. The effects of water temperature, pH, and dissolved organic matter (DOM) on the sampling rate (R s) of PFCs were evaluated with a static renewal system. During laboratory validation over a 14-day period, the uptake kinetics of PFCs was linear with the POCIS. DOM and water temperature slightly influenced POCIS uptake rates, which is in consistent with the theory for uptake into POCIS. Therefore, within a narrow span of DOM and water temperatures, it was unnecessary to adjust the R s value for POCIS. Laboratory experiments were conducted with water over pH ranges of 3, 7, and 9. The R s values declined significantly with pH increase for PFCs. Although pH affected the uptake of PFCs, the effect was less than twofold. Application of the R s value to analyze PFCs with POCIS deployed in the field provided similar concentrations obtained from grab samples.

  9. Psychometric properties of the communication Confidence Rating Scale for Aphasia (CCRSA): phase 1.

    PubMed

    Cherney, Leora R; Babbitt, Edna M; Semik, Patrick; Heinemann, Allen W

    2011-01-01

    Confidence is a construct that has not been explored previously in aphasia research. We developed the Communication Confidence Rating Scale for Aphasia (CCRSA) to assess confidence in communicating in a variety of activities and evaluated its psychometric properties using rating scale (Rasch) analysis. The CCRSA was administered to 21 individuals with aphasia before and after participation in a computer-based language therapy study. Person reliability of the 8-item CCRSA was .77. The 5-category rating scale demonstrated monotonic increases in average measures from low to high ratings. However, one item ("I follow news, sports, stories on TV/movies") misfit the construct defined by the other items (mean square infit = 1.69, item-measure correlation = .41). Deleting this item improved reliability to .79; the 7 remaining items demonstrated excellent fit to the underlying construct, although there was a modest ceiling effect in this sample. Pre- to posttreatment changes on the 7-item CCRSA measure were statistically significant using a paired samples t test. Findings support the reliability and sensitivity of the CCRSA in assessing participants' self-report of communication confidence. Further evaluation of communication confidence is required with larger and more diverse samples.

  10. A Simulation Study of Acoustic-Assisted Tracking of Whales for Mark-Recapture Surveys

    PubMed Central

    Peel, David; Miller, Brian S.; Kelly, Natalie; Dawson, Steve; Slooten, Elisabeth; Double, Michael C.

    2014-01-01

    Collecting enough data to obtain reasonable abundance estimates of whales is often difficult, particularly when studying rare species. Passive acoustics can be used to detect whale sounds and are increasingly used to estimate whale abundance. Much of the existing effort centres on the use of acoustics to estimate abundance directly, e.g. analysing detections in a distance sampling framework. Here, we focus on acoustics as a tool incorporated within mark-recapture surveys. In this context, acoustic tools are used to detect and track whales, which are then photographed or biopsied to provide data for mark-recapture analyses. The purpose of incorporating acoustics is to increase the encounter rate beyond using visual searching only. While this general approach is not new, its utility is rarely quantified. This paper predicts the “acoustically-assisted” encounter rate using a discrete-time individual-based simulation of whales and survey vessel. We validate the simulation framework using existing data from studies of sperm whales. We then use the framework to predict potential encounter rates in a study of Antarctic blue whales. We also investigate the effects of a number of the key parameters on encounter rate. Mean encounter rates from the simulation of sperm whales matched well with empirical data. Variance of encounter rate, however, was underestimated. The simulation of Antarctic blue whales found that passive acoustics should provide a 1.7–3.0 fold increase in encounter rate over visual-only methods. Encounter rate was most sensitive to acoustic detection range, followed by vocalisation rate. During survey planning and design, some indication of the relationship between expected sample size and effort is paramount; this simulation framework can be used to predict encounter rates and establish this relationship. For a case in point, the simulation framework indicates unequivocally that real-time acoustic tracking should be considered for quantifying the abundance of Antarctic blue whales via mark-recapture methods. PMID:24827919

  11. A simulation study of acoustic-assisted tracking of whales for mark-recapture surveys.

    PubMed

    Peel, David; Miller, Brian S; Kelly, Natalie; Dawson, Steve; Slooten, Elisabeth; Double, Michael C

    2014-01-01

    Collecting enough data to obtain reasonable abundance estimates of whales is often difficult, particularly when studying rare species. Passive acoustics can be used to detect whale sounds and are increasingly used to estimate whale abundance. Much of the existing effort centres on the use of acoustics to estimate abundance directly, e.g. analysing detections in a distance sampling framework. Here, we focus on acoustics as a tool incorporated within mark-recapture surveys. In this context, acoustic tools are used to detect and track whales, which are then photographed or biopsied to provide data for mark-recapture analyses. The purpose of incorporating acoustics is to increase the encounter rate beyond using visual searching only. While this general approach is not new, its utility is rarely quantified. This paper predicts the "acoustically-assisted" encounter rate using a discrete-time individual-based simulation of whales and survey vessel. We validate the simulation framework using existing data from studies of sperm whales. We then use the framework to predict potential encounter rates in a study of Antarctic blue whales. We also investigate the effects of a number of the key parameters on encounter rate. Mean encounter rates from the simulation of sperm whales matched well with empirical data. Variance of encounter rate, however, was underestimated. The simulation of Antarctic blue whales found that passive acoustics should provide a 1.7-3.0 fold increase in encounter rate over visual-only methods. Encounter rate was most sensitive to acoustic detection range, followed by vocalisation rate. During survey planning and design, some indication of the relationship between expected sample size and effort is paramount; this simulation framework can be used to predict encounter rates and establish this relationship. For a case in point, the simulation framework indicates unequivocally that real-time acoustic tracking should be considered for quantifying the abundance of Antarctic blue whales via mark-recapture methods.

  12. Studies of the physical, yield and failure behavior of aliphatic polyketones

    NASA Astrophysics Data System (ADS)

    Karttunen, Nicole Renee

    This thesis describes an investigation into the multiaxial yield and failure behavior of an aliphatic polyketone terpolymer. The behavior is studied as a function of: stress state, strain rate, temperature, and sample processing conditions. Results of this work include: elucidation of the behavior of a recently commercialized polymer, increased understanding of the effects listed above, insight into the effects of processing conditions on the morphology of the polyketone, and a description of yield strength of this material as a function of stress state, temperature, and strain rate. The first portion of work focuses on the behavior of a set of samples that are extruded under "common" processing conditions. Following this reference set of tests, the effect of testing this material at different temperatures is studied. A total of four different temperatures are examined. In addition, the effect of altering strain rate is examined. Testing is performed under pseudo-strain rate control at constant nominal octahedral shear strain rate for each failure envelope. A total of three different rates are studied. An extension of the first portion of work involves modeling the yield envelope. This is done by combining two approaches: continuum level and molecular level. The use of both methods allows the description of the yield envelope as a function of stress state, strain rate and temperature. The second portion of work involves the effects of processing conditions. For this work, additional samples are extruded with different shear and thermal histories than the "standard" material. One set of samples is processed with shear rates higher and lower than the standard. A second set is processed at higher and lower cooling rates than the standard. In order to understand the structural cause for changes in behavior with processing conditions, morphological characterization is performed on these samples. In particular, the effect on spherulitic structure is important. Residual stresses are also determined to be important to the behavior of the samples. Finally, an investigation into the crystalline structure of a family of aliphatic polyketones is performed. The effects of side group concentration and size are described.

  13. Treatment Trials for Neonatal Seizures: The Effect of Design on Sample Size

    PubMed Central

    Stevenson, Nathan J.; Boylan, Geraldine B.; Hellström-Westas, Lena; Vanhatalo, Sampsa

    2016-01-01

    Neonatal seizures are common in the neonatal intensive care unit. Clinicians treat these seizures with several anti-epileptic drugs (AEDs) to reduce seizures in a neonate. Current AEDs exhibit sub-optimal efficacy and several randomized control trials (RCT) of novel AEDs are planned. The aim of this study was to measure the influence of trial design on the required sample size of a RCT. We used seizure time courses from 41 term neonates with hypoxic ischaemic encephalopathy to build seizure treatment trial simulations. We used five outcome measures, three AED protocols, eight treatment delays from seizure onset (Td) and four levels of trial AED efficacy to simulate different RCTs. We performed power calculations for each RCT design and analysed the resultant sample size. We also assessed the rate of false positives, or placebo effect, in typical uncontrolled studies. We found that the false positive rate ranged from 5 to 85% of patients depending on RCT design. For controlled trials, the choice of outcome measure had the largest effect on sample size with median differences of 30.7 fold (IQR: 13.7–40.0) across a range of AED protocols, Td and trial AED efficacy (p<0.001). RCTs that compared the trial AED with positive controls required sample sizes with a median fold increase of 3.2 (IQR: 1.9–11.9; p<0.001). Delays in AED administration from seizure onset also increased the required sample size 2.1 fold (IQR: 1.7–2.9; p<0.001). Subgroup analysis showed that RCTs in neonates treated with hypothermia required a median fold increase in sample size of 2.6 (IQR: 2.4–3.0) compared to trials in normothermic neonates (p<0.001). These results show that RCT design has a profound influence on the required sample size. Trials that use a control group, appropriate outcome measure, and control for differences in Td between groups in analysis will be valid and minimise sample size. PMID:27824913

  14. Uranium mobility during interaction of rhyolitic obsidian, perlite and felsite with alkaline carbonate solution: T = 120° C, P = 210 kg/cm2

    USGS Publications Warehouse

    Zielinski, Robert A.

    1979-01-01

    Well-characterized samples of rhyolitic obsidian, perlite and felsite from a single lava flow are leached of U by alkaline oxidizing solutions under open-system conditions. Pressure, temperature, flow rate and solution composition are held constant in order to evaluate the relative importance of differences in surface area and crystallinity. Under the experimental conditions U removal from crushed glassy samples proceeds by a mechanism of glass dissolution in which U and silica are dissolved in approximately equal weight fractions. The rate of U removal from crushed glassy samples increases with decreasing average grain size (surface area). Initial rapid loss of a small component (≈ 2.5%) of the total U from crushed felsite. followed by much slower U loss, reflects variable rates of attack of numerous uranium sites. The fractions of U removed during the experiment ranged from 3.2% (felsite) to 27% (perlite). An empirical method for evaluating the relative rate of U loss from contemporaneous volcanic rocks is presented which incorporates leaching results and rock permeability data.

  15. Thermal conductivity of water-saturated rocks from the KTB pilot hole at temperatures of 25 to 300°C

    USGS Publications Warehouse

    Pribnow, D.; Williams, C.F.; Sass, J.H.; Keating, R.

    1996-01-01

    The conductivitites of selected gneiss (two) and amphibolite (one) core samples have been measured under conditions of elevated temperature and pressure with a needle-probe. Water-saturated thermal conductivity measurements spanning temperatures from 25 to 300??C and hydrostatic pressures of 0.1 and 34 MPa confirm the general decrease in conductivity with increasing temperature but deviate significantly from results reported from measurements on dry samples over the same temperature range. The thermal conductivity of water-saturated amphibolite decreases with temperature at a rate approximately 40% less than the rate for dry amphibolite, and the conductivity of water-saturated gneiss decreases at a rate approximately 20% less than the rate for dry gneiss. The available evidence points to thermal cracking as the primary cause of the more rapid decrease in dry thermal conductivity with temperature. The effects of thermal cracking were also observed in the water-saturated samples but resulted in a net decrease in room-temperature conductivity of less than 3%. These results highlight the importance of duplicating in-situ conditions when determining thermal conductivity for the deep crust.

  16. Ultrasonic acoustic levitation for fast frame rate X-ray protein crystallography at room temperature.

    PubMed

    Tsujino, Soichiro; Tomizaki, Takashi

    2016-05-06

    Increasing the data acquisition rate of X-ray diffraction images for macromolecular crystals at room temperature at synchrotrons has the potential to significantly accelerate both structural analysis of biomolecules and structure-based drug developments. Using lysozyme model crystals, we demonstrated the rapid acquisition of X-ray diffraction datasets by combining a high frame rate pixel array detector with ultrasonic acoustic levitation of protein crystals in liquid droplets. The rapid spinning of the crystal within a levitating droplet ensured an efficient sampling of the reciprocal space. The datasets were processed with a program suite developed for serial femtosecond crystallography (SFX). The structure, which was solved by molecular replacement, was found to be identical to the structure obtained by the conventional oscillation method for up to a 1.8-Å resolution limit. In particular, the absence of protein crystal damage resulting from the acoustic levitation was carefully established. These results represent a key step towards a fully automated sample handling and measurement pipeline, which has promising prospects for a high acquisition rate and high sample efficiency for room temperature X-ray crystallography.

  17. Ultrasonic acoustic levitation for fast frame rate X-ray protein crystallography at room temperature

    NASA Astrophysics Data System (ADS)

    Tsujino, Soichiro; Tomizaki, Takashi

    2016-05-01

    Increasing the data acquisition rate of X-ray diffraction images for macromolecular crystals at room temperature at synchrotrons has the potential to significantly accelerate both structural analysis of biomolecules and structure-based drug developments. Using lysozyme model crystals, we demonstrated the rapid acquisition of X-ray diffraction datasets by combining a high frame rate pixel array detector with ultrasonic acoustic levitation of protein crystals in liquid droplets. The rapid spinning of the crystal within a levitating droplet ensured an efficient sampling of the reciprocal space. The datasets were processed with a program suite developed for serial femtosecond crystallography (SFX). The structure, which was solved by molecular replacement, was found to be identical to the structure obtained by the conventional oscillation method for up to a 1.8-Å resolution limit. In particular, the absence of protein crystal damage resulting from the acoustic levitation was carefully established. These results represent a key step towards a fully automated sample handling and measurement pipeline, which has promising prospects for a high acquisition rate and high sample efficiency for room temperature X-ray crystallography.

  18. Ultrasonic acoustic levitation for fast frame rate X-ray protein crystallography at room temperature

    PubMed Central

    Tsujino, Soichiro; Tomizaki, Takashi

    2016-01-01

    Increasing the data acquisition rate of X-ray diffraction images for macromolecular crystals at room temperature at synchrotrons has the potential to significantly accelerate both structural analysis of biomolecules and structure-based drug developments. Using lysozyme model crystals, we demonstrated the rapid acquisition of X-ray diffraction datasets by combining a high frame rate pixel array detector with ultrasonic acoustic levitation of protein crystals in liquid droplets. The rapid spinning of the crystal within a levitating droplet ensured an efficient sampling of the reciprocal space. The datasets were processed with a program suite developed for serial femtosecond crystallography (SFX). The structure, which was solved by molecular replacement, was found to be identical to the structure obtained by the conventional oscillation method for up to a 1.8-Å resolution limit. In particular, the absence of protein crystal damage resulting from the acoustic levitation was carefully established. These results represent a key step towards a fully automated sample handling and measurement pipeline, which has promising prospects for a high acquisition rate and high sample efficiency for room temperature X-ray crystallography. PMID:27150272

  19. Frequency-Modulated Continuous Flow Analysis Electrospray Ionization Mass Spectrometry (FM-CFA-ESI-MS) for Sample Multiplexing.

    PubMed

    Filla, Robert T; Schrell, Adrian M; Coulton, John B; Edwards, James L; Roper, Michael G

    2018-02-20

    A method for multiplexed sample analysis by mass spectrometry without the need for chemical tagging is presented. In this new method, each sample is pulsed at unique frequencies, mixed, and delivered to the mass spectrometer while maintaining a constant total flow rate. Reconstructed ion currents are then a time-dependent signal consisting of the sum of the ion currents from the various samples. Spectral deconvolution of each reconstructed ion current reveals the identity of each sample, encoded by its unique frequency, and its concentration encoded by the peak height in the frequency domain. This technique is different from other approaches that have been described, which have used modulation techniques to increase the signal-to-noise ratio of a single sample. As proof of concept of this new method, two samples containing up to 9 analytes were multiplexed. The linear dynamic range of the calibration curve was increased with extended acquisition times of the experiment and longer oscillation periods of the samples. Because of the combination of the samples, salt had little effect on the ability of this method to achieve relative quantitation. Continued development of this method is expected to allow for increased numbers of samples that can be multiplexed.

  20. Countering imbalanced datasets to improve adverse drug event predictive models in labor and delivery.

    PubMed

    Taft, L M; Evans, R S; Shyu, C R; Egger, M J; Chawla, N; Mitchell, J A; Thornton, S N; Bray, B; Varner, M

    2009-04-01

    The IOM report, Preventing Medication Errors, emphasizes the overall lack of knowledge of the incidence of adverse drug events (ADE). Operating rooms, emergency departments and intensive care units are known to have a higher incidence of ADE. Labor and delivery (L&D) is an emergency care unit that could have an increased risk of ADE, where reported rates remain low and under-reporting is suspected. Risk factor identification with electronic pattern recognition techniques could improve ADE detection rates. The objective of the present study is to apply Synthetic Minority Over Sampling Technique (SMOTE) as an enhanced sampling method in a sparse dataset to generate prediction models to identify ADE in women admitted for labor and delivery based on patient risk factors and comorbidities. By creating synthetic cases with the SMOTE algorithm and using a 10-fold cross-validation technique, we demonstrated improved performance of the Naïve Bayes and the decision tree algorithms. The true positive rate (TPR) of 0.32 in the raw dataset increased to 0.67 in the 800% over-sampled dataset. Enhanced performance from classification algorithms can be attained with the use of synthetic minority class oversampling techniques in sparse clinical datasets. Predictive models created in this manner can be used to develop evidence based ADE monitoring systems.

  1. Influence of the creep ageing process on the fatigue properties of components from V95pchT2 (analog 7175T76) and V95ochT2 (analog 7475) aluminium alloys

    NASA Astrophysics Data System (ADS)

    Larichkin, A.; Zakharchenko, K.; Gorev, B.; Kapustin, V.; Maksimovskiy, E.

    2017-10-01

    Influence of conditions of technological process of forming thick panels of a given geometry on fatigue limit of flat specimens from the V95ochT2 and V95pchT2 (analogues 7475 and 7175T76) alloys (Al-Mg-Cu-Zn) has been analysed. The process has been simulated experimentally on flat samples for temperatures 20, 165 and 420°C. The process includes: non-elastic strain in the range 10-5 - 10-2 s-1 up to 2% of total strain, followed by heat treatment according to T2 mode (quenching and aging). Fatigue life tests were carried out both on solid samples and on samples with a hole. It has been shown that resistance to fatigue of the observed alloys after forming at the annealing temperature (420°C) is comparable to the basic material resistance to fatigue. Meso-structure analysis showed absence of stress in grains. It is established that, on average, the shape of the grains is the same for a series of samples for different temperatures and loading rates. The results of testing samples with a hole showed that fatigue limit slightly decreases in samples which were previously deformed at (420°C), with respect to the durability of samples from the material in basic state. With an increase in rate of pre-strain, the relative number of cycles before destruction occurs increased.

  2. Accounting for Relatedness in Family Based Genetic Association Studies

    PubMed Central

    McArdle, P.F.; O’Connell, J.R.; Pollin, T.I.; Baumgarten, M.; Shuldiner, A.R.; Peyser, P.A.; Mitchell, B.D.

    2007-01-01

    Objective Assess the differences in point estimates, power and type 1 error rates when accounting for and ignoring family structure in genetic tests of association. Methods We compare by simulation the performance of analytic models using variance components to account for family structure and regression models that ignore relatedness for a range of possible family based study designs (i.e., sib pairs vs. large sibships vs. nuclear families vs. extended families). Results Our analyses indicate that effect size estimates and power are not significantly affected by ignoring family structure. Type 1 error rates increase when family structure is ignored, as density of family structures increases, and as trait heritability increases. For discrete traits with moderate levels of heritability and across many common sampling designs, type 1 error rates rise from a nominal 0.05 to 0.11. Conclusion Ignoring family structure may be useful in screening although it comes at a cost of a increased type 1 error rate, the magnitude of which depends on trait heritability and pedigree configuration. PMID:17570925

  3. Impact of changing from staining to culture techniques on detection rates of Campylobacter spp. in routine stool samples in Chile.

    PubMed

    Porte, Lorena; Varela, Carmen; Haecker, Thomas; Morales, Sara; Weitzel, Thomas

    2016-05-13

    Campylobacter is a leading cause of bacterial gastroenteritis, but sensitive diagnostic methods such as culture are expensive and often not available in resource limited settings. Therefore, direct staining techniques have been developed as a practical and economical alternative. We analyzed the impact of replacing Campylobacter staining with culture for routine stool examinations in a private hospital in Chile. From January to April 2014, a total of 750 consecutive stool samples were examined in parallel by Hucker stain and Campylobacter culture. Isolation rates of Campylobacter were determined and the performance of staining was evaluated against culture as the gold standard. Besides, isolation rates of Campylobacter and other enteric pathogens were compared to those of past years. Campylobacter was isolated by culture in 46 of 750 (6.1 %) stool samples. Direct staining only identified three samples as Campylobacter positive and reached sensitivity and specificity values of 6.5 and 100 %, respectively. In comparison to staining-based detection rates of previous years, we observed a significant increase of Campylobacter cases in our patients. Direct staining technique for Campylobacter had a very low sensitivity compared to culture. Staining methods might lead to a high rate of false negative results and an underestimation of the importance of campylobacteriosis. With the inclusion of Campylobacter culture, this pathogen became a leading cause of intestinal infection in our patient population.

  4. Chemistry and Formation of the Beilby Layer During Polishing of Fused Silica Glass

    DOE PAGES

    Suratwala, Tayyab; Steele, William; Wong, Lana; ...

    2015-05-19

    The chemical characteristics and the proposed formation mechanisms of the modified surface layer (called the Beilby layer) on polished fused silica glasses are described. Fused silica glass samples were polished using different slurries, polyurethane pads, and at different rotation rates. The concentration profiles of several key contaminants, such as Ce, K, and H, were measured in the near surface layer of the polished samples using Secondary Ion Mass Spectroscopy (SIMS). The penetration of K, originating from KOH used for pH control during polishing, decreased with increase in polishing material removal rate. In contrast, penetration of the Ce and H increasedmore » with increase in polishing removal rate. In addition, Ce penetration was largely independent of the other polishing parameters (e.g., particle size distribution and the properties of the polishing pad). The resulting K concentration depth profiles are described using a two-step diffusion process: (1) steady-state moving boundary diffusion (due to material removal during polishing) followed by (2) simple diffusion during ambient postpolishing storage. Using known alkali metal diffusion coefficients in fused silica glass, this diffusion model predicts concentration profiles that are consistent with the measured data at various polishing material removal rates. On the other hand, the observed Ce profiles are inconsistent with diffusion based transport. Rather we propose that Ce penetration is governed by the ratio of Ce–O–Si and Si–O–Si hydrolysis rates; where this ratio increases with interface temperature (which increases with polishing material removal rate) resulting in greater Ce penetration into the Beilby layer. Calculated Ce surface concentrations using this mechanism are in good agreement to the observed change in measured Ce surface concentrations with polishing material removal rate. In conclusion, these new insights into the chemistry of the Beilby layer, combined together with details of the single particle removal function during polishing, are used to develop a more detailed and quantitative picture of the polishing process and the formation of the Beilby layer.« less

  5. Blood flow measurement of human skeletal muscle during various exercise intensity using diffuse correlation spectroscopy (DCS)

    NASA Astrophysics Data System (ADS)

    Murakami, Yuya; Ono, Yumie; Ichinose, Masashi

    2017-02-01

    We studied blood flow dynamics of active skeletal muscle using diffuse correlation spectroscopy (DCS), an emerging optical modality that is suitable for noninvasive quantification of microcirculation level in deep tissue. Seven healthy subjects conducted 0.5 Hz dynamic handgrip exercise for 3 minutes at intensities of 10, 20, 30, and 50 % of maximal voluntary contraction (MVC). DCS could detect the time-dependent increase of the blood flow response of the forearm muscle for continuous exercises, and the increase ratios of the mean blood flow through the exercise periods showed good correlation with the exercise intensities. We also compared blood flow responses detected from DCS with two different photon sampling rates and found that an appropriate photon sampling rates should be selected to follow the wide-ranged increase in the muscle blood flow with dynamic exercise. Our results demonstrate the possibility for utilizing DCS in a field of sports medicine to noninvasively evaluate the dynamics of blood flow in the active muscles.

  6. The impact of Hurricane Hugo and the San Francisco earthquake on a sample of people with rheumatoid arthritis.

    PubMed

    Grady, K E; Reisine, S T; Fifield, J; Lee, N R; McVay, J; Kelsey, M E

    1991-06-01

    The health effects of two natural disasters on 32 people with rheumatoid arthritis (RA) were assessed during the second-year wave of interviews in an ongoing 3-year study. Although the severity of Hurricane Hugo exceeded that of the San Francisco earthquake, no significant differences in health impacts were found. Both groups reported significantly increased ratings of RA activity, pain, and depression compared with ratings during the first year. However, comparison with the rest of the sample (n = 767) showed that increases in disease activity and pain were a general phenomenon but that the increase in depression was unique to the disaster subsample. Physician health status assessments also indicated that those who experienced the disaster were more likely to be classified in later stages of the disease subsequent to the disaster and were more likely to experience flares. These results suggest that people with RA may constitute a special high-risk population for adverse health effects after natural disasters.

  7. Violent men have more sons: further evidence for the generalized Trivers-Willard hypothesis (gTWH).

    PubMed

    Kanazawa, Satoshi

    2006-04-21

    The generalized Trivers-Willard hypothesis (gTWH) [Kanazawa, S., 2005a. Big and tall parents have more sons; further generalizations of the Trivers-Willard hypothesis. J. Theor. Biol. 235, 583-590] proposes that parents who possess any heritable trait which increases the male reproductive success at a greater rate than female reproductive success in a given environment have a higher-than-expected offspring sex ratio, and parents who possess any heritable trait which increases the female reproductive success at a greater rate than male reproductive success in a given environment have a lower-than-expected offspring sex ratio. One heritable trait which increases the reproductive success of sons significantly more than that of daughters in the ancestral environment is the tendency toward violence and aggression. I therefore predict that violent parents have a higher-than-expected offspring sex ratio (more sons). The analysis of both American samples and a British sample demonstrates that battered women, who are mated to violent men, have significantly more sons than daughters.

  8. Palaeonummulites venosus: Natural growth rates and quantification by means of CT investigation

    NASA Astrophysics Data System (ADS)

    Kinoshita, Shunichi; Eder, Wolfgang; Woeger, Julia; Hohenegger, Johann; Briguglio, Antonino

    2016-04-01

    Symbiont-bearing larger benthic Foraminifera (LBF) are long-living marine (possibly >1 year), single-celled organisms with complex calcium carbonate shells. Reproduction period, longevity and chamber building rate of LBF are important for population dynamics studies. It was expected that growth experiments in laboratory cultures cannot be used for estimation of chamber building rates and longevity studies although the laboratory conditions were simulated to natural conditions. Therefore, it is necessary to study individual and population growth under natural conditions for getting natural information. Therefore, the 'natural laboratory' method was developed to calculate the averaged chamber building rate and averaged longevity of species based on monthly sampling at fixed sampling stations and to compare with laboratory cultures simulating environmental conditions as close as possible to the natural environment. Thus, in this study, samples of living individuals were collected in 16 monthly intervals at 50m depth in front of Sesoko Island, Okinawa, Japan. We used micro-computed tomography (microCT) to investigate the chamber number of every specimen from the samples immediately dried after sampling. Single non dried specimens were cultured and the time of chamber building was obtained using microphotographs counted for every specimen at 2 to 4 days time intervals. The investigation using the natural laboratory method of Palaeonummulites venosus is based on the decomposition of the monthly frequency distributions into normally distributed components. Then the shift of the component parameters mean and standard deviation was used to calculate the necessary character of maximum chamber number and the Michaelis Menten function was applied to estimate the chamber building rate under natural conditions. This resulted in two reproduction periods, the first starting in May and the second in September, both showing the same chamber building rates, where the first shows a slightly stronger increase in the initial part. Longevity seems to be round about one year. Due to the several reproduction periods, the existence of small and large specimens in the same sample and the bimodal distributions can be explained. The cultured individuals shows a much lower chamber building rate, often demonstrating a longer period with no chamber production just after sampling, the results of sampling shock. This is the first time that it can be shown that chamber building rates and longevities cannot be based on laboratory investigations.

  9. Influence of speech sample on perceptual rating of hypernasality.

    PubMed

    Medeiros, Maria Natália Leite de; Fukushiro, Ana Paula; Yamashita, Renata Paciello

    2016-07-07

    To investigate the influence of speech sample of spontaneous conversation or sentences repetition on intra and inter-rater hypernasality reliability. One hundred and twenty audio recorded speech samples (60 containing spontaneous conversation and 60 containing repeated sentences) of individuals with repaired cleft palate±lip, both genders, aged between 6 and 52 years old (mean=21±10) were selected and edited. Three experienced speech and language pathologists rated hypernasality according to their own criteria using 4-point scale: 1=absence of hypernasality, 2=mild hypernasality, 3=moderate hypernasality and 4=severe hypernasality, first in spontaneous speech samples and 30 days after, in sentences repetition samples. Intra- and inter-rater agreements were calculated for both speech samples and were statistically compared by the Z test at a significance level of 5%. Comparison of intra-rater agreements between both speech samples showed an increase of the coefficients obtained in the analysis of sentences repetition compared to those obtained in spontaneous conversation. Comparison between inter-rater agreement showed no significant difference among the three raters for the two speech samples. Sentences repetition improved intra-raters reliability of perceptual judgment of hypernasality. However, the speech sample had no influence on reliability among different raters.

  10. Obesity and Body Size Preferences of Jordanian Women

    ERIC Educational Resources Information Center

    Madanat, Hala; Hawks, Steven R.; Angeles, Heidi N.

    2011-01-01

    The nutrition transition is associated with increased obesity rates and increased desire to be thin. This study evaluates the relationship between actual body size and desired body size among a representative sample of 800 Jordanian women. Using Stunkard's body silhouettes, women were asked to identify their current and ideal body sizes, healthy…

  11. Proof firm downsizing and diagnosis-specific disability pensioning in Norway.

    PubMed

    Claussen, Bjørgulf; Næss, Øyvind; Reime, Leif Jostein; Leyland, Alastair H

    2013-01-11

    We wanted to investigate if firm downsizing is related to an increased rate of disability pensions among the former employed, especially for those with musculoskeletal and psychiatric diagnoses, and for those having to leave the firm. Statistics Norway provided a linked file with demographic information and all social security grants from the National Insurance Administration for 1992-2004 for all inhabitants in Norway. Our sample was aged 30-55 years in 1995, being alive, employed and not having a disability pension at the end of 2000. Downsizing was defined as percent change in number of employed per firm from 1995 to end 2000. Employment data were missing for 25.6% of the sample. Disability pension rates in the next four years were 25% higher for those experiencing a 30-59% downsizing than for those not experiencing a reduction of the workforce. 1-29% and 60-100% downsizing did not have this effect. Stayers following down-sizing had higher disability pension rates than leavers. What we have called complex musculoskeletal and psychiatric diagnoses were relatively most common. Moderate downsizing is followed by a significant increase in disability pension rates in the following four years, often with complex musculoskeletal and psychiatric diagnoses.

  12. Response rate, response time, and economic costs of survey research: A randomized trial of practicing pharmacists.

    PubMed

    Hardigan, Patrick C; Popovici, Ioana; Carvajal, Manuel J

    2016-01-01

    There is a gap between increasing demands from pharmacy journals, publishers, and reviewers for high survey response rates and the actual responses often obtained in the field by survey researchers. Presumably demands have been set high because response rates, times, and costs affect the validity and reliability of survey results. Explore the extent to which survey response rates, average response times, and economic costs are affected by conditions under which pharmacist workforce surveys are administered. A random sample of 7200 U.S. practicing pharmacists was selected. The sample was stratified by delivery method, questionnaire length, item placement, and gender of respondent for a total of 300 observations within each subgroup. A job satisfaction survey was administered during March-April 2012. Delivery method was the only classification showing significant differences in response rates and average response times. The postal mail procedure accounted for the highest response rates of completed surveys, but the email method exhibited the quickest turnaround. A hybrid approach, consisting of a combination of postal and electronic means, showed the least favorable results. Postal mail was 2.9 times more cost effective than the email approach and 4.6 times more cost effective than the hybrid approach. Researchers seeking to increase practicing pharmacists' survey participation and reduce response time and related costs can benefit from the analytical procedures tested here. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Hospitalizations for critically ill children with traumatic brain injuries: a longitudinal analysis.

    PubMed

    Tilford, John M; Aitken, Mary E; Anand, K J S; Green, Jerril W; Goodman, Allen C; Parker, James G; Killingsworth, Jeffrey B; Fiser, Debra H; Adelson, P David

    2005-09-01

    This study examines the incidence, utilization of procedures, and outcomes for critically ill children hospitalized with traumatic brain injury over the period 1988-1999 to describe the benefits of improved treatment. Retrospective analysis of hospital discharges was conducted using data from the Health Care Cost and Utilization Project Nationwide Inpatient Sample that approximates a 20% sample of U.S. acute care hospitals. Hospital inpatient stays from all types of U.S. community hospitals. The study sample included all children aged 0-21 with a primary or secondary ICD-9-CM diagnosis code for traumatic brain injury and a procedure code for either endotracheal intubation or mechanical ventilation. None. Deaths occurring during hospitalization were used to calculate mortality rates. Use of intracranial pressure monitoring and surgical openings of the skull were investigated as markers for the aggressiveness of treatment. Patients were further classified by insurance status, household income, and hospital characteristics. Over the 12-yr study period, mortality rates decreased 8 percentage points whereas utilization of intracranial pressure monitoring increased by 11 percentage points. The trend toward more aggressive management of traumatic brain injury corresponded with improved hospital outcomes over time. Lack of insurance was associated with vastly worse outcomes. An estimated 6,437 children survived their traumatic brain injury hospitalization because of improved treatment, and 1,418 children died because of increased mortality risk associated with being uninsured. Improved treatment was valued at approximately dollar 17 billion, whereas acute care hospitalization costs increased by dollar 1.5 billion (in constant 2000 dollars). Increased mortality in uninsured children was associated with a dollar 3.76 billion loss in economic benefits. More aggressive management of pediatric traumatic brain injury appears to have contributed to reduced mortality rates over time and saved thousands of lives. Additional lives could be saved if mortality rates could be equalized between insured and uninsured children.

  14. 44Ca/42Ca and 143Nd/144Nd isotope variations in Cretaceous Eocene Tethyan francolites and their bearing on phosphogenesis in the southern Tethys

    NASA Astrophysics Data System (ADS)

    Soudry, David; Segal, Irena; Nathan, Yaacov; Glenn, Craig R.; Halicz, Ludwik; Lewy, Zeev; Vonderhaar, Denys L.

    2004-05-01

    Measurements of 44Ca/42Ca and 143Nd/144Nd isotope ratios in carbonate fluorapatite (CFA) through the Aptian Eocene section of the Negev (Israel), together with quantified rates of P and Ca accumulation and bulk sedimentation, permit an examination of the relationships of these five factors to Tethyan phosphogenesis. The data provide an Aptian Eocene (ca. 70 Ma) record of the Ca isotope composition of 35 CFA samples (24 of which were also analyzed for Nd isotopes), representing 11 time-stratigraphic phosphate horizons within the sequence. The δ44Ca values are significantly lower in the Aptian Albian samples (δ44Ca = -0.11‰ to -0.06‰) than in the Campanian Eocene samples (δ44Ca = +0.22‰ to +0.42‰), whereas the ɛNd(T) values increase from continental crust like in the Aptian Albian [ɛNd(T) = -10.9] to more radiogenic, Pacific-like [ɛNd(T) = -6.6 to -6.1] in the Campanian. Both peaks of δ44Ca and ɛNd(T) in the Campanian coincide with the peak of Tethyan phosphogenesis in the Negev, which is marked by a sharp increase of P accumulation rates (from <200 μmol·cm-2·k.y.-1 in pre-Campanian time to ˜1700 μmol·cm-2·k.y.-1 in the Campanian) and a decrease in rates of Ca accumulation and bulk sedimentation. The coincident increases of δ44Ca and ɛNd(T) values and P accumulation rates in the Negev area during the Campanian suggest that they are related in this time interval and were induced by the global Late Cretaceous sea- level rise and increasing circumequatorial Tethyan flow.

  15. Spall fracture in aluminium alloy at high strain rates

    NASA Astrophysics Data System (ADS)

    Joshi, K. D.; Rav, Amit; Sur, Amit; Kaushik, T. C.; Gupta, Satish C.

    2016-05-01

    Spall fracture strength and dynamic yield strength has been measured in 8mm thick target plates of aluminium alloy Al2024-T4 at high strain rates generated in three plate impact experiments carried out at impact velocities of 180 m/s, 370 m/s and 560m/s, respectively, using single stage gas gun facility. In each experiment, the free surface velocity history of the Al2024-T4 sample plate measured employing velocity interferometer system for any reflector (VISAR) is used to determine the spall strength and dynamic yield strength of this material. The spall strength of 1.11 GPa, 1.16 GPa and 1.43 GPa, determined from measured free surface velocity history of sample material in three experiments performed at impact velocity of 180 m/s, 370 m/s and 560 m/s, respectively, are higher than the quasi static value of 0.469 GPa and display almost linearly increasing trend with increasing impact velocity or equivalently with increasing strain rates. The average strain rates just ahead of the spall fracture are determined to be 1.9×10 4/s, 2.0×104/s and 2.5×104/s, respectively. The dynamic yield strength determined in the three experiments range from 0.383 GPa to 0.407 GPa, which is higher than the quasi static value of 0.324GPa.

  16. Elucidating the effects of solar panel waste glass substitution on the physical and mechanical characteristics of clay bricks.

    PubMed

    Lin, Kae-Long; Huang, Long-Sheng; Shie, Je-Lueng; Cheng, Ching-Jung; Lee, Ching-Hwa; Chang, Tien-Chin

    2013-01-01

    This study deals with the effect of solar panel waste glass on fired clay bricks. Brick samples were heated to temperatures which varied from 700-1000 degrees C for 6 h, with a heating rate of 10 degrees C min(-1). The material properties of the resultant material were then determined, including speciation variation, loss on ignition, shrinkage, bulk density, 24-h absorption rate, compressive strength and salt crystallization. The results indicate that increasing the amount of solar panel waste glass resulted in a decrease in the water absorption rate and an increase in the compressive strength of the solar panel waste glass bricks. The 24-h absorption rate and compressive strength of the solar panel waste glass brick made from samples containing 30% solar panel waste glass sintered at 1000 degrees C all met the Chinese National Standard (CNS) building requirements for first-class brick (compressive strengths and water absorption of the bricks were 300 kg cm(-2) and 10% of the brick, respectively). The addition of solar panel waste glass to the mixture reduced the degree of firing shrinkage. The salt crystallization test and wet-dry tests showed that the addition of solar panel waste glass had highly beneficial effects in that it increased the durability of the bricks. This indicates that solar panel waste glass is indeed suitable for the partial replacement of clay in bricks.

  17. Intravenous Nicotine Self-Administration in Smokers: Dose-Response Function and Sex Differences.

    PubMed

    Jensen, Kevin P; DeVito, Elise E; Valentine, Gerald; Gueorguieva, Ralitza; Sofuoglu, Mehmet

    2016-07-01

    Sex differences in the sensitivity to nicotine may influence vulnerability to tobacco dependence. The goal of this study was to investigate the dose-response function for the reinforcing and subjective effects of intravenous nicotine in male and female smokers. Tobacco-dependent subjects (12 male and 14 female) participated in four experimental sessions in which they received sample infusions of saline and nicotine (0.1, 0.2, 0.3, or 0.4 mg doses) in a randomized double-blind crossover design. During each session, subjects first received the sample infusions, and heart rate (HR), blood pressure, and subjective stimulatory, pleasurable and aversive responses were monitored. Immediately following the sample infusions, subjects self-administered either nicotine or saline in six double-blind forced-choice trials. A sex by dose interaction was observed in the nicotine choice paradigm. Nicotine self-administration rate was negatively correlated with nicotine dose in males (males displayed choice preference for low doses of nicotine over high doses of nicotine), but no significant relationship between dose and choice preference was evident in females. Relative to placebo, sample doses of nicotine increased heart rate and blood pressure, and induced stimulatory, pleasurable, and aversive subjective effects. Diastolic blood pressure increased dose dependently in males, but not in females. These findings, which demonstrate sex differences in nicotine self-administration for doses that are near to the reinforcement threshold, suggest that male and female smokers may respond differently to the changes in nicotine doses available for self-administration.

  18. Effects of post-reflow cooling rate and thermal aging on growth behavior of interfacial intermetallic compound between SAC305 solder and Cu substrate

    NASA Astrophysics Data System (ADS)

    Hu, Xiaowu; Xu, Tao; Jiang, Xiongxin; Li, Yulong; Liu, Yi; Min, Zhixian

    2016-04-01

    The interfacial reactions between Cu and Sn3Ag0.5Cu (SAC305) solder reflowed under various cooling rates were investigated. It is found that the cooling rate is an important parameter in solder reflow process because it influences not only microstructure of solder alloy but also the morphology and growth of intermetallic compounds (IMCs) formed between solder and Cu substrate. The experimental results indicate that only scallop-like Cu6Sn5 IMC layer is observed between solder and Cu substrate in case of water cooling and air cooling, while bilayer composed of scallop-like Cu6Sn5 and thin layer-like Cu3Sn is detected under furnace cooling due to sufficient reaction time to form Cu3Sn between Cu6Sn5 IMC and Cu substrate which resulted from slow cooling rate. Samples with different reflow cooling rates were further thermal-aged at 423 K. And it is found that the thickness of IMC increases linearly with square root of aging time. The growth constants of interfacial IMC layer during aging were obtained and compared for different cooling rates, indicating that the IMC layer thickness increased faster in samples under low cooling rate than in the high cooling rate under the same aging condition. The long prismatic grains were formed on the existing interfacial Cu6Sn5 grains to extrude deeply into solder matrix with lower cooling rate and long-term aging, and the Cu6Sn5 grains coarsened linearly with cubic root of aging time.

  19. Comparison of concentration methods for rapid detection of hookworm ova in wastewater matrices using quantitative PCR.

    PubMed

    Gyawali, P; Ahmed, W; Jagals, P; Sidhu, J P S; Toze, S

    2015-12-01

    Hookworm infection contributes around 700 million infections worldwide especially in developing nations due to increased use of wastewater for crop production. The effective recovery of hookworm ova from wastewater matrices is difficult due to their low concentrations and heterogeneous distribution. In this study, we compared the recovery rates of (i) four rapid hookworm ova concentration methods from municipal wastewater, and (ii) two concentration methods from sludge samples. Ancylostoma caninum ova were used as surrogate for human hookworm (Ancylostoma duodenale and Necator americanus). Known concentration of A. caninum hookworm ova were seeded into wastewater (treated and raw) and sludge samples collected from two wastewater treatment plants (WWTPs) in Brisbane and Perth, Australia. The A. caninum ova were concentrated from treated and raw wastewater samples using centrifugation (Method A), hollow fiber ultrafiltration (HFUF) (Method B), filtration (Method C) and flotation (Method D) methods. For sludge samples, flotation (Method E) and direct DNA extraction (Method F) methods were used. Among the four methods tested, filtration (Method C) method was able to recover higher concentrations of A. caninum ova consistently from treated wastewater (39-50%) and raw wastewater (7.1-12%) samples collected from both WWTPs. The remaining methods (Methods A, B and D) yielded variable recovery rate ranging from 0.2 to 40% for treated and raw wastewater samples. The recovery rates for sludge samples were poor (0.02-4.7), although, Method F (direct DNA extraction) provided 1-2 orders of magnitude higher recovery rate than Method E (flotation). Based on our results it can be concluded that the recovery rates of hookworm ova from wastewater matrices, especially sludge samples, can be poor and highly variable. Therefore, choice of concentration method is vital for the sensitive detection of hookworm ova in wastewater matrices. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  20. Screening for chromosomal anomalies in the first trimester: does repeat maternal serum screening improve detection rates?

    PubMed

    Spencer, Kevin; Cuckle, Howard S

    2002-10-01

    To assess the within person biological variability of first trimester maternal serum biochemical markers of trisomy 21 across the 10-14 week gestational period. To evaluate whether repeat sampling and testing of free beta-hCG and PAPP-A during this period would result in an improved detection rate. Women presenting at the first trimester OSCAR clinic have blood collected prior to ultrasound dating and nuchal translucency measurement. All samples are analysed for free beta-hCG and PAPP-A before an accurate estimate of gestation is available. In 10% of cases the gestation is prior to the minimum time for NT measurement (11 weeks) and these women are rebooked for a repeat visit to the clinic at the appropriate time. Our fetal database was interrogated to obtain cases in which two maternal blood samples had been collected and analysed in the 10-14 week period. Using data from the marker correlations and statistical modelling, the impact of repeat testing on detection rate for trisomy 21 at a fixed 5% false positive rate, was assessed. 261 pairs of data were available for analysis collected over a 3 year period. The correlation between free beta-hCG in sample 1 and sample 2 was 0.890 and that for PAPP-A was 0.827. The average within person biological variation for free beta-hCG was 21% and 32% for PAPP-A. The increase in detection rate when using both sets of marker data was 3.5% when using serum biochemistry and maternal age, and 1.3% when using nuchal translucency, serum biochemistry and maternal age. Repeat sampling and testing of maternal serum biochemical markers is unlikely to substantially improve first trimester screening performance. Copyright 2002 John Wiley & Sons, Ltd.

  1. Longitudinal design considerations to optimize power to detect variances and covariances among rates of change: Simulation results based on actual longitudinal studies

    PubMed Central

    Rast, Philippe; Hofer, Scott M.

    2014-01-01

    We investigated the power to detect variances and covariances in rates of change in the context of existing longitudinal studies using linear bivariate growth curve models. Power was estimated by means of Monte Carlo simulations. Our findings show that typical longitudinal study designs have substantial power to detect both variances and covariances among rates of change in a variety of cognitive, physical functioning, and mental health outcomes. We performed simulations to investigate the interplay among number and spacing of occasions, total duration of the study, effect size, and error variance on power and required sample size. The relation between growth rate reliability (GRR) and effect size to the sample size required to detect power ≥ .80 was non-linear, with rapidly decreasing sample sizes needed as GRR increases. The results presented here stand in contrast to previous simulation results and recommendations (Hertzog, Lindenberger, Ghisletta, & von Oertzen, 2006; Hertzog, von Oertzen, Ghisletta, & Lindenberger, 2008; von Oertzen, Ghisletta, & Lindenberger, 2010), which are limited due to confounds between study length and number of waves, error variance with GCR, and parameter values which are largely out of bounds of actual study values. Power to detect change is generally low in the early phases (i.e. first years) of longitudinal studies but can substantially increase if the design is optimized. We recommend additional assessments, including embedded intensive measurement designs, to improve power in the early phases of long-term longitudinal studies. PMID:24219544

  2. Predicting fractional bed load transport rates: Application of the Wilcock‐Crowe equations to a regulated gravel bed river

    USGS Publications Warehouse

    Gaeuman, David; Andrews, E.D.; Krause, Andreas; Smith, Wes

    2009-01-01

    Bed load samples from four locations in the Trinity River of northern California are analyzed to evaluate the performance of the Wilcock‐Crowe bed load transport equations for predicting fractional bed load transport rates. Bed surface particles become smaller and the fraction of sand on the bed increases with distance downstream from Lewiston Dam. The dimensionless reference shear stress for the mean bed particle size (τ*rm) is largest near the dam, but varies relatively little between the more downstream locations. The relation between τ*rm and the reference shear stresses for other size fractions is constant across all locations. Total bed load transport rates predicted with the Wilcock‐Crowe equations are within a factor of 2 of sampled transport rates for 68% of all samples. The Wilcock‐Crowe equations nonetheless consistently under‐predict the transport of particles larger than 128 mm, frequently by more than an order of magnitude. Accurate prediction of the transport rates of the largest particles is important for models in which the evolution of the surface grain size distribution determines subsequent bed load transport rates. Values of τ*rm estimated from bed load samples are up to 50% larger than those predicted with the Wilcock‐Crowe equations, and sampled bed load transport approximates equal mobility across a wider range of grain sizes than is implied by the equations. Modifications to the Wilcock‐Crowe equation for determining τ*rm and the hiding function used to scale τ*rm to other grain size fractions are proposed to achieve the best fit to observed bed load transport in the Trinity River.

  3. Kinetic comparison of microbial assemblages for the anaerobic treatment of wastewater with high sulfate and heavy metal contents.

    PubMed

    Sinbuathong, Nusara; Sirirote, Pramote; Liengcharernsit, Winai; Khaodhiar, Sutha; Watts, Daniel J

    2009-01-01

    Mixed-microbial assemblages enriched from a septic tank, coastal sediment samples, the digester sludge of a brewery wastewater treatment plant and acidic sulfate soil samples were compared on the basis of growth rate, waste and sulfate reduction rate under sulfate reducing conditions at 30 degrees C. The specific growth rate of various cultures was in the range 0.0013-0.0022 hr(-1). Estimates of waste and sulfate reduction rate were obtained by fitting substrate depletion and sulfate reduction data with the Michaelis-Menten equation. The waste reduction rates were in the range 4x10(-8)-1x10(-7) I mg(-1) hr(-1) and generally increased in the presence of copper, likely by copper sulfide precipitation that reduced sulfide and copper toxicity and thus protected the anaerobic microbes. Anaerobic microorganisms from a brewery digester sludge were found to be the most appropriate culture for the treatment of wastewater with high sulfate and heavy metal content due to their growth rate, and waste and sulfate reduction rate.

  4. Photosynthesis and Ribulose 1,5-Bisphosphate Concentrations in Intact Leaves of Xanthium strumarium L. 1

    PubMed Central

    Mott, Keith A.; Jensen, Richard G.; O'Leary, James W.; Berry, Joseph A.

    1984-01-01

    The interacting effects of the rate of ribulose 1,5-bisphosphate (RuBP) regeneration and the rate of RuBP utilization as influenced by the amount and activation of RuBP carboxylase on photosynthesis and RuBP concentrations were resolved in experiments which examined the kinetics of the response of photosynthesis and RuBP concentrations after step changes from a rate-saturating to a rate-limiting light intensity in Xanthium strumarium. Because RuBP carboxylase requires several minutes to deactivate in vivo, it was possible to observe the effect of reducing the rate of RuBP regeneration on the RuBP concentration at constant enzyme activation state by sampling very soon after reducing the light intensity. Samples taken over longer time periods showed the effect of changes in enzyme activation at constant RuBP regeneration rate on RuBP concentration and photosynthetic rate. Within 15 s of lowering the light intensity from 1500 to 600 microEinsteins per square meter per second the RuBP concentration in the leaves dropped below the enzyme active site concentration, indicating that RuBP regeneration rate was limiting for photosynthesis. After longer intervals of time, the RuBP concentration in the leaf increased as the RuBP carboxylase assumed a new steady state activation level. No change in the rate of photosynthesis was observed during the interval that RuBP concentration increased. It is concluded that the rate of photosynthesis at the lower light intensity was limited by the rate of RuBP regeneration and that parallel changes in the activation of RuBP carboxylase occurred such that concentrations of RuBP at steady state were not altered by changes in light intensity. PMID:16663982

  5. Photosynthesis and Ribulose 1,5-Bisphosphate Concentrations in Intact Leaves of Xanthium strumarium L.

    PubMed

    Mott, K A; Jensen, R G; O'leary, J W; Berry, J A

    1984-12-01

    The interacting effects of the rate of ribulose 1,5-bisphosphate (RuBP) regeneration and the rate of RuBP utilization as influenced by the amount and activation of RuBP carboxylase on photosynthesis and RuBP concentrations were resolved in experiments which examined the kinetics of the response of photosynthesis and RuBP concentrations after step changes from a rate-saturating to a rate-limiting light intensity in Xanthium strumarium. Because RuBP carboxylase requires several minutes to deactivate in vivo, it was possible to observe the effect of reducing the rate of RuBP regeneration on the RuBP concentration at constant enzyme activation state by sampling very soon after reducing the light intensity. Samples taken over longer time periods showed the effect of changes in enzyme activation at constant RuBP regeneration rate on RuBP concentration and photosynthetic rate. Within 15 s of lowering the light intensity from 1500 to 600 microEinsteins per square meter per second the RuBP concentration in the leaves dropped below the enzyme active site concentration, indicating that RuBP regeneration rate was limiting for photosynthesis. After longer intervals of time, the RuBP concentration in the leaf increased as the RuBP carboxylase assumed a new steady state activation level. No change in the rate of photosynthesis was observed during the interval that RuBP concentration increased. It is concluded that the rate of photosynthesis at the lower light intensity was limited by the rate of RuBP regeneration and that parallel changes in the activation of RuBP carboxylase occurred such that concentrations of RuBP at steady state were not altered by changes in light intensity.

  6. Relations between Response Trajectories on the Continuous Performance Test and Teacher-Rated Problem Behaviors in Preschoolers

    PubMed Central

    Allan, Darcey M.; Lonigan, Christopher J.

    2014-01-01

    Although both the Continuous Performance Test (CPT) and behavior rating scales are used in both practice and research to assess inattentive and hyperactive/impulsive behaviors, the correlations between performance on the CPT and teachers' ratings are typically only small-to-moderate. This study examined trajectories of performance on a low target-frequency visual CPT in a sample of preschool children and how these trajectories were associated with teacher-ratings of problem behaviors (i.e., inattention, hyperactivity/impulsivity [H/I], and oppositional/defiant behavior). Participants included 399 preschool children (Mean age = 56 months; 49.4% female; 73.7% White/Caucasian). An ADHD-rating scale was completed by teachers, and the CPT was completed by the preschoolers. Results showed that children's performance across four temporal blocks on the CPT was not stable across the duration of the task, with error rates generally increasing from initial to later blocks. The predictive relations of teacher-rated problem behaviors to performance trajectories on the CPT were examined using growth curve models. Higher rates of teacher-reported inattention and H/I were uniquely associated with higher rates of initial omission errors and initial commission errors, respectively. Higher rates of teacher-reported overall problem behaviors were associated with increasing rates of omission but not commission errors during the CPT; however, the relation was not specific to one type of problem behavior. The results of this study indicate that the pattern of errors on the CPT in preschool samples is complex and may be determined by multiple behavioral factors. These findings have implications for the interpretation of CPT performance in young children. PMID:25419645

  7. Relations between response trajectories on the continuous performance test and teacher-rated problem behaviors in preschoolers.

    PubMed

    Allan, Darcey M; Lonigan, Christopher J

    2015-06-01

    Although both the continuous performance test (CPT) and behavior rating scales are used in both practice and research to assess inattentive and hyperactive/impulsive behaviors, the correlations between performance on the CPT and teachers' ratings are typically only small-to-moderate. This study examined trajectories of performance on a low target-frequency visual CPT in a sample of preschool children and how these trajectories were associated with teacher-ratings of problem behaviors (i.e., inattention, hyperactivity/impulsivity [H/I], and oppositional/defiant behavior). Participants included 399 preschool children (mean age = 56 months; 49.4% female; 73.7% White/Caucasian). An attention deficit/hyperactivity disorder (ADHD) rating scale was completed by teachers, and the CPT was completed by the preschoolers. Results showed that children's performance across 4 temporal blocks on the CPT was not stable across the duration of the task, with error rates generally increasing from initial to later blocks. The predictive relations of teacher-rated problem behaviors to performance trajectories on the CPT were examined using growth curve models. Higher rates of teacher-reported inattention and H/I were uniquely associated with higher rates of initial omission errors and initial commission errors, respectively. Higher rates of teacher-reported overall problem behaviors were associated with increasing rates of omission but not commission errors during the CPT; however, the relation was not specific to 1 type of problem behavior. The results of this study indicate that the pattern of errors on the CPT in preschool samples is complex and may be determined by multiple behavioral factors. These findings have implications for the interpretation of CPT performance in young children. (c) 2015 APA, all rights reserved).

  8. Dissolution Rates of Biogenic Carbonate Sediments from the Bermuda Platform

    NASA Astrophysics Data System (ADS)

    Finlay, A. J.; Andersson, A. J.

    2016-02-01

    The contribution of biogenic carbonate sediment dissolution rates to overall net reef accretion/erosion (under both present and future oceanic pCO2 levels) has been strikingly neglected, despite experimental results indicating that sediment dissolution might be more sensitive to ocean acidification (OA) than calcification. Dissolution of carbonate sediments could impact net reef accretion rates as well as the formation and preservation of valuable marine and terrestrial ecosystems. Bulk sediment dissolution rates of samples from the Bermuda carbonate platform were measured in natural seawater at pCO2 values ranging from approximately 3500 μatm to 9000 μatm. This range of pCO2 levels incorporates values currently observed in porewaters on the Bermuda carbonate platform as well as a potential future increase in porewater pCO2 levels due to OA. Sediment samples from two different stations on the reef platform were analyzed for grain size and mineralogy. Dissolution rates of sediments in the dominant grain size fraction of the platform (500-1000 μm) from both stations ranged between 16.25 and 47.19 (± 0.27 to 0.79) μmoles g-1 hr-1 and are comparable to rates previously obtained from laboratory experiments on other natural carbonate sediments. At a pCO2 of 3500 μatm, rates from both samples were similar, despite their differing mineralogy. However, at pCO2 levels above 3500 μatm, the sediment sample with a greater weight percent of Mg-calcite had slightly higher dissolution rates. Despite many laboratory studies on biogenic carbonate dissolution, a significant disparity still exists between laboratory measurements and field observations. Performing additional controlled, laboratory experiments on natural sediment may help to elucidate the reasons for this disparity.

  9. An assessment of false positive rates for malaria rapid diagnostic tests caused by non-Plasmodium infectious agents and immunological factors.

    PubMed

    Gatton, Michelle L; Ciketic, Sadmir; Barnwell, John W; Cheng, Qin; Chiodini, Peter L; Incardona, Sandra; Bell, David; Cunningham, Jane; González, Iveth J

    2018-01-01

    Malaria rapid diagnostic tests (RDTs) can produce false positive (FP) results in patients with human African trypanosomiasis and rheumatoid factor (RF), but specificity against other infectious agents and immunological factors is largely unknown. Low diagnostic specificity caused by cross-reactivity may lead to over-estimates of the number of malaria cases and over-use of antimalarial drugs, at the cost of not diagnosing and treating the true underlying condition. Data from the WHO Malaria RDT Product Testing Programme was analysed to assess FP rates of 221 RDTs against four infectious agents (Chagas, dengue, Leishmaniasis and Schistosomiasis) and four immunological factors (anti-nuclear antibody, human anti-mouse antibody (HAMA), RF and rapid plasma regain). Only RDTs with a FP rate against clean negative samples less than 10% were included. Paired t-tests were used to compare product-specific FP rates on clean negative samples and samples containing non-Plasmodium infectious agents and immunological factors. Forty (18%) RDTs showed no FP results against any tested infectious agent or immunological factor. In the remaining RDTs significant and clinically relevant increases in FP rates were observed for samples containing HAMA and RF (P<0.001). There were significant correlations between product-matched FP rates for RF and HAMA on all RDT test bands (P<0.001), and FP rates for each infectious agent and immunological factor were also correlated between test bands of combination RDTs (P≤0.002). False positive results against non-Plasmodium infectious agents and immunological factors does not appear to be a universal property of malaria RDTs. However, since many malaria RDTs have elevated FP rates against HAMA and RF positive samples practitioners may need to consider the possibility of false positive results for malaria in patients with conditions that stimulate HAMA or RF.

  10. Human pharmaceuticals in Portuguese rivers: The impact of water scarcity in the environmental risk.

    PubMed

    Pereira, André M P T; Silva, Liliana J G; Laranjeiro, Célia S M; Meisel, Leonor M; Lino, Celeste M; Pena, Angelina

    2017-12-31

    Pharmaceuticals occurrence and environmental risk assessment were assessed in Portuguese surface waters, evaluating the impact of wastewater treatment plants (WWTPs) and river flow rates. Twenty three pharmaceuticals from 6 therapeutic groups, including metabolites and 1 transformation product, were analysed in 72 samples collected from 20 different sites, upstream and downstream the selected WWTPs, in two different seasons. Analysis was performed by solid phase extraction followed by liquid chromatography coupled to tandem mass spectroscopy. Pharmaceuticals were detected in 27.8% of the samples. Selective serotonin reuptake inhibitors (SSRIs), anti-inflammatories and antibiotics presented the highest detection frequencies (27.8, 23.6 and 23.6%, respectively) and average concentrations (37.9, 36.1 and 33.5ngL -1 , respectively). When assessing the impact of WWTPs, an increase of 21.4% in the average concentrations was observed in the samples located downstream these facilities, when compared with the upstream samples. Increased detection frequencies and concentrations were observed at lower flow rates, both when comparing summer and winter campaigns and by evaluating the different rivers. Risk quotients (RQs) higher than one were found for two pharmaceuticals, concerning two trophic levels. However, since Iberian rivers are highly influenced by water scarcity, in drought periods, the flow rates in these rivers can decrease at least ten times from the lowest value observed in the sampling campaigns. In these conditions, RQs higher than 1 would be observed for 5 pharmaceuticals, additionally, all the detected pharmaceuticals (11) would present RQs higher than 0.1. These results emphasize that the river flow rate represents an important parameter influencing pharmaceuticals concentrations, highlighting the ecotoxicological pressure, especially due to water scarcity in drought periods. This should be a priority issue in the environmental policies for minimizing its impact in the aquatic environment. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. A Factorial Data Rate and Dwell Time Experiment in the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    DeLoach, R.

    2000-01-01

    This report is an introductory tutorial on the application of formal experiment design methods to wind tunnel testing, for the benefit of aeronautical engineers with little formal experiment design training. It also describes the results of a Study to determine whether increases in the sample rate and dwell time of the National Transonic Facility data system Would result in significant changes in force and moment data. Increases in sample rate from 10 samples per second to 50 samples per second were examined, as were changes in dwell time from one second per data point to two seconds. These changes were examined for a representative aircraft model in a range of tunnel operating conditions defined by angles of attack from 0 deg to 3.8 degrees, total pressure from 15.0 psi to 24.1 psi, and Mach numbers from 0.52 to 0.82. No statistically significant effect was associated with the change in sample rate. The change in dwell time from one second to two seconds affected axial force measurements, and to a lesser degree normal force measurements. This dwell effect comprises a "rectification error" caused by incomplete cancellation of the positive and negative elements of certain low frequency dynamic components that are not rejected by the one-Hz low-pass filters of the data system. These low frequency effects may be due to tunnel circuit phenomena and other sources. The magnitude of the dwell effect depends on dynamic pressure, with angle of attack and Mach number influencing the strength of this dependence. An analysis is presented which suggests that the magnitude of the rectification error depends on the ratio of measurement dwell time to the period of the low-frequency dynamics, as well as the amplitude of the dynamics The essential conclusion of this analysis is that extending the dwell time (or, equivalently, replicating short-dwell data points) reduces the rectification error.

  12. Effect of Phosphate, Fluoride, and Nitrate on Gibbsite Dissolution Rate and Solubility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herting, Daniel L.

    2014-01-29

    Laboratory tests have been completed with simulated tank waste samples to investigate the effects of phosphate, fluoride, and nitrate on the dissolution rate and equilibrium solubility of gibbsite in sodium hydroxide solution at 22 and 40{degrees}C. Results are compared to relevant literature data and to computer model predictions. The presence of sodium nitrate (3 M) caused a reduction in the rate of gibbsite dissolution in NaOH, but a modest increase in the equilibrium solubility of aluminum. The increase in solubility was not as large, though, as the increase predicted by the computer model. The presence of phosphate, either as sodiummore » phosphate or sodium fluoride phosphate, had a negligible effect on the rate of gibbsite dissolution, but caused a slight increase in aluminum solubility. The magnitude of the increased solubility, relative to the increase caused by sodium nitrate, suggests that the increase is due to ionic strength (or water activity) effects, rather than being associated with the specific ion involved. The computer model predicted that phosphate would cause a slight decrease in aluminum solubility, suggesting some Al-PO4 interaction. No evidence was found of such an interaction.« less

  13. Increased fMRI Sensitivity at Equal Data Burden Using Averaged Shifted Echo Acquisition

    PubMed Central

    Witt, Suzanne T.; Warntjes, Marcel; Engström, Maria

    2016-01-01

    There is growing evidence as to the benefits of collecting BOLD fMRI data with increased sampling rates. However, many of the newly developed acquisition techniques developed to collect BOLD data with ultra-short TRs require hardware, software, and non-standard analytic pipelines that may not be accessible to all researchers. We propose to incorporate the method of shifted echo into a standard multi-slice, gradient echo EPI sequence to achieve a higher sampling rate with a TR of <1 s with acceptable spatial resolution. We further propose to incorporate temporal averaging of consecutively acquired EPI volumes to both ameliorate the reduced temporal signal-to-noise inherent in ultra-fast EPI sequences and reduce the data burden. BOLD data were collected from 11 healthy subjects performing a simple, event-related visual-motor task with four different EPI sequences: (1) reference EPI sequence with TR = 1440 ms, (2) shifted echo EPI sequence with TR = 700 ms, (3) shifted echo EPI sequence with every two consecutively acquired EPI volumes averaged and effective TR = 1400 ms, and (4) shifted echo EPI sequence with every four consecutively acquired EPI volumes averaged and effective TR = 2800 ms. Both the temporally averaged sequences exhibited increased temporal signal-to-noise over the shifted echo EPI sequence. The shifted echo sequence with every two EPI volumes averaged also had significantly increased BOLD signal change compared with the other three sequences, while the shifted echo sequence with every four EPI volumes averaged had significantly decreased BOLD signal change compared with the other three sequences. The results indicated that incorporating the method of shifted echo into a standard multi-slice EPI sequence is a viable method for achieving increased sampling rate for collecting event-related BOLD data. Further, consecutively averaging every two consecutively acquired EPI volumes significantly increased the measured BOLD signal change and the subsequently calculated activation map statistics. PMID:27932947

  14. The Self-Adapting Focused Review System. Probability sampling of medical records to monitor utilization and quality of care.

    PubMed

    Ash, A; Schwartz, M; Payne, S M; Restuccia, J D

    1990-11-01

    Medical record review is increasing in importance as the need to identify and monitor utilization and quality of care problems grow. To conserve resources, reviews are usually performed on a subset of cases. If judgment is used to identify subgroups for review, this raises the following questions: How should subgroups be determined, particularly since the locus of problems can change over time? What standard of comparison should be used in interpreting rates of problems found in subgroups? How can population problem rates be estimated from observed subgroup rates? How can the bias be avoided that arises because reviewers know that selected cases are suspected of having problems? How can changes in problem rates over time be interpreted when evaluating intervention programs? Simple random sampling, an alternative to subgroup review, overcomes the problems implied by these questions but is inefficient. The Self-Adapting Focused Review System (SAFRS), introduced and described here, provides an adaptive approach to record selection that is based upon model-weighted probability sampling. It retains the desirable inferential properties of random sampling while allowing reviews to be concentrated on cases currently thought most likely to be problematic. Model development and evaluation are illustrated using hospital data to predict inappropriate admissions.

  15. Estimating malaria transmission from humans to mosquitoes in a noisy landscape

    PubMed Central

    Reiner, Robert C.; Guerra, Carlos; Donnelly, Martin J.; Bousema, Teun; Drakeley, Chris; Smith, David L.

    2015-01-01

    A basic quantitative understanding of malaria transmission requires measuring the probability a mosquito becomes infected after feeding on a human. Parasite prevalence in mosquitoes is highly age-dependent, and the unknown age-structure of fluctuating mosquito populations impedes estimation. Here, we simulate mosquito infection dynamics, where mosquito recruitment is modelled seasonally with fractional Brownian noise, and we develop methods for estimating mosquito infection rates. We find that noise introduces bias, but the magnitude of the bias depends on the ‘colour' of the noise. Some of these problems can be overcome by increasing the sampling frequency, but estimates of transmission rates (and estimated reductions in transmission) are most accurate and precise if they combine parity, oocyst rates and sporozoite rates. These studies provide a basis for evaluating the adequacy of various entomological sampling procedures for measuring malaria parasite transmission from humans to mosquitoes and for evaluating the direct transmission-blocking effects of a vaccine. PMID:26400195

  16. Sampling effort and estimates of species richness based on prepositioned area electrofisher samples

    USGS Publications Warehouse

    Bowen, Z.H.; Freeman, Mary C.

    1998-01-01

    Estimates of species richness based on electrofishing data are commonly used to describe the structure of fish communities. One electrofishing method for sampling riverine fishes that has become popular in the last decade is the prepositioned area electrofisher (PAE). We investigated the relationship between sampling effort and fish species richness at seven sites in the Tallapoosa River system, USA based on 1,400 PAE samples collected during 1994 and 1995. First, we estimated species richness at each site using the first-order jackknife and compared observed values for species richness and jackknife estimates of species richness to estimates based on historical collection data. Second, we used a permutation procedure and nonlinear regression to examine rates of species accumulation. Third, we used regression to predict the number of PAE samples required to collect the jackknife estimate of species richness at each site during 1994 and 1995. We found that jackknife estimates of species richness generally were less than or equal to estimates based on historical collection data. The relationship between PAE electrofishing effort and species richness in the Tallapoosa River was described by a positive asymptotic curve as found in other studies using different electrofishing gears in wadable streams. Results from nonlinear regression analyses indicted that rates of species accumulation were variable among sites and between years. Across sites and years, predictions of sampling effort required to collect jackknife estimates of species richness suggested that doubling sampling effort (to 200 PAEs) would typically increase observed species richness by not more than six species. However, sampling effort beyond about 60 PAE samples typically increased observed species richness by < 10%. We recommend using historical collection data in conjunction with a preliminary sample size of at least 70 PAE samples to evaluate estimates of species richness in medium-sized rivers. Seventy PAE samples should provide enough information to describe the relationship between sampling effort and species richness and thus facilitate evaluation of a sampling effort.

  17. Influence of ultrasound pretreatment on wood physiochemical structure.

    PubMed

    He, Zhengbin; Wang, Zhenyu; Zhao, Zijian; Yi, Songlin; Mu, Jun; Wang, Xiaoxu

    2017-01-01

    As an initial step to increase the use of renewable biomass resources, this study was aimed at investigating the effects of ultrasound pretreatment on structural changes of wood. Samples were pretreated by ultrasound with the power of 300W and frequency of 28kHz in aqueous soda solution, aqueous acetic acid, or distilled water, then pretreated and control samples were characterized via X-ray diffraction (XRD), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), and thermogravimetric analysis (TGA). The results shown that ultrasound pretreatment is indeed effective in modifying the physiochemical structure of eucalyptus wood; the pretreatment decreased the quantity of alkali metals (e.g., potassium, calcium and magnesium) in the resulting material. Compared to the control group, the residual char content of samples pretreated in aqueous soda solution increased by 10.08%-20.12% and the reaction temperature decreased from 361°C to 341°C, however, in samples pretreated by ultrasound in acetic solution or distilled water, the residual char content decreased by 12.40%-21.45% and there were no significant differences in reactivity apart from a slightly higher maximum reaction rate. Ultrasound pretreatment increased the samples' crystallinity up to 35.5% and successfully removed cellulose, hemicellulose, and lignin from the samples; the pretreatment also increased the exposure of the sample to the treatment solutions, broke down sample pits, and generated collapses and microchannels on sample pits, and removed attachments in the samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Asparagus stem as a new lignocellulosic biomass feedstock for anaerobic digestion: increasing hydrolysis rate, methane production and biodegradability by alkaline pretreatment.

    PubMed

    Chen, Xiaohua; Gu, Yu; Zhou, Xuefei; Zhang, Yalei

    2014-07-01

    Recently, anaerobic digestion of lignocellulosic biomass for methane production has attracted considerable attention. However, there is little information regarding methane production from asparagus stem, a typical lignocellulosic biomass, by anaerobic digestion. In this study, alkaline pretreatment of asparagus stem was investigated for its ability to increase hydrolysis rate and methane production and to improve biodegradability (BD). The hydrolysis rate increased with increasing NaOH dose, due to higher removal rates of lignin and hemicelluloses. However, the optimal NaOH dose was 6% (w/w) according to the specific methane production (SMP). Under this condition, the SMP and the technical digestion time of the NaOH-treated asparagus stem were 242.3 mL/g VS and 18 days, which were 38.4% higher and 51.4% shorter than those of the untreated sample, respectively. The BD was improved from 40.1% to 55.4%. These results indicate that alkaline pretreatment could be an efficient method for increasing methane production from asparagus stem. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Changes in denudation rates and erosion processes in the transition from a low-relief, arid orogen interior to a high-relief, humid mountain-front setting, Toro Basin, southern Central Andes

    NASA Astrophysics Data System (ADS)

    Tofelde, S.; Düsing, W.; Schildgen, T. F.; Wittmann, H.; Alonso, R. N.; Strecker, M. R.

    2017-12-01

    In tectonically active mountain belts positive correlations between denudation rates and hillslope angles are commonly observed, supporting the notion that landscape morphology may reflect tectonic forcing. However, this relationship generally breaks down at 30°, when hillslopes reach threshold angles. Beyond this threshold, faster denudation may occur by an increased contribution from mass-wasting processes. We test this idea in the 4000 km2 Toro Basin, a fault-bounded basin in the Eastern Cordillera of the southern Central Andes. This N-S oriented basin is located between low-relief, arid conditions in the orogen interior (N) and a high-relief, humid setting at its fluvial outlet (S). We measured in-situ produced 10Be concentration in fluvial sediments, which can be converted into basin-mean denudation rates, assuming a spatially uniform contribution of sediment from the catchment. However, in landslide-influenced areas, this assumption is often violated. Previous studies have suggested that clast-size material is mainly contributed by mass-wasting processes, whereas sand is derived from a broad range of erosional processes. Hence, a combination of clast and sand samples can reveal information about the basin-mean denudation rate as well as the contribution of mass-wasting processes. We sampled 13 pebble (1-3 cm) and sand (250-500 µm) pairs across the basin. The sand-derived denudation rates increase from N to S, ranging from 0.010 mm/yr to 1.337 mm/yr, and reveal a non-linear positive correlation with median basin slope. The clast/sand ratios also increase from N to S, indicating amplified mass-wasting processes with increasing slopes. To test if our ratios represent a real shift in erosional processes, we mapped different erosional processes in the study area (e.g. deep-seated landslides, scree erosion,.., diffusion). We assume that today's distribution of processes has not changed over the integration time of 10Be derived denudation rates. This detailed erosion inventory indicates a shift in the dominant erosional processes with increasing clast/sand ratios and thus with increasing slopes. We provide empirical data supporting the hypothesis that higher denudation rates can be achieved by an increased contribution of mass-wasting processes after threshold slopes have been reached.

  20. Scale and Sampling Effects on Floristic Quality

    PubMed Central

    2016-01-01

    Floristic Quality Assessment (FQA) is increasingly influential for making land management decisions, for directing conservation policy, and for research. But, the basic ecological properties and limitations of its metrics are ill defined and not well understood–especially those related to sample methods and scale. Nested plot data from a remnant tallgrass prairie sampled annually over a 12-year period, were used to investigate FQA properties associated with species detection rates, species misidentification rates, sample year, and sample grain/area. Plot size had no apparent effect on Mean C (an area’s average Floristic Quality level), nor did species detection levels above 65% detection. Simulated species misidentifications only affected Mean C values at greater than 10% in large plots, when the replaced species were randomly drawn from the broader county-wide species pool. Finally, FQA values were stable over the 12-year study, meaning that there was no evidence that the metrics exhibit year effects. The FQA metric Mean C is demonstrated to be robust to varied sample methodologies related to sample intensity (plot size, species detection rate), as well as sample year. These results will make FQA measures even more appealing for informing land-use decisions, policy, and research for two reasons: 1) The sampling effort needed to generate accurate and consistent site assessments with FQA measures is shown to be far lower than what has previously been assumed, and 2) the stable properties and consistent performance of metrics with respect to sample methods will allow for a remarkable level of comparability of FQA values from different sites and datasets compared to other commonly used ecological metrics. PMID:27489959

  1. Embryotoxic and genotoxic effects of sewage effluents in zebrafish embryo using multiple endpoint testing.

    PubMed

    Babić, Sanja; Barišić, Josip; Višić, Hrvoje; Sauerborn Klobučar, Roberta; Topić Popović, Natalija; Strunjak-Perović, Ivančica; Čož-Rakovac, Rozelindra; Klobučar, Göran

    2017-05-15

    Wastewater treatment plant (WWTP) effluents are often complex mixtures of various organic and inorganic substances. Quality control of wastewaters and sludges has been regulated with measuring several physico-chemical parameters and sometimes using biological methods with non-specific responses, while synergistic action mechanisms of contaminants in such complex mixtures is still unknown. Toxic effects of wastewaters within and downstream of the WWTP in City of Virovitica, Croatia, were tested on zebrafish Danio rerio using a set of biomarkers that enabled an insight in wastewaters toxic potential on embryos at the cellular, tissue and the whole organism level during an early ontogenesis (24 and 48 hpf). Exposure of embryos to the wastewater samples from WWTP Virovitica increased mortality and abnormality rate. Heart rate, spontaneous movements and pigmentation formation were also markedly affected. Biochemical markers confirmed the presence of MXR inhibitors in all tested wastewater samples, indicating the increase of pollutant accumulation in the cell/organism. Also, a tendency of DNA damage decrease measured with Comet assay was evident in wastewater samples downstream from WWTP although control levels were not reached in any environmental sample. Histopathological analysis showed that exposure to tested samples resulted in impaired muscle organization, notochord malformation and retardation in eye and brain development at embryos 48 hpf. Furthermore, semi-quantitative histopathology assessment indicated increased percentage of embryo defects in river water sampled several kilometers downstream from the WWTP, confirming toxic potential of WWTP effluents. Extension of the zebrafish embryotoxicity test (ZET) with biochemical and histopathological biomarkers could serve as a guiding principle in biomonitoring of wastewater contamination. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. 2-Deoxyadenosine triphosphate restores the contractile function of cardiac myofibril from adult dogs with naturally occurring dilated cardiomyopathy

    PubMed Central

    Cheng, Yuanhua; Hogarth, Kaley A.; O'Sullivan, M. Lynne; Regnier, Michael

    2015-01-01

    Dilated cardiomyopathy (DCM) is a major type of heart failure resulting from loss of systolic function. Naturally occurring canine DCM is a widely accepted experimental paradigm for studying human DCM. 2-Deoxyadenosine triphosphate (dATP) can be used by myosin and is a superior energy substrate over ATP for cross-bridge formation and increased systolic function. The objective of this study was to evaluate the beneficial effect of dATP on contractile function of cardiac myofibrils from dogs with naturally occurring DCM. We measured actomyosin NTPase activity and contraction/relaxation properties of isolated myofibrils from nonfailing (NF) and DCM canine hearts. NTPase assays indicated replacement of ATP with dATP significantly increased myofilament activity in both NF and DCM samples. dATP significantly improved maximal tension of DCM myofibrils to the NF sample level. dATP also restored Ca2+ sensitivity of tension that was reduced in DCM samples. Similarly, dATP increased the kinetics of contractile activation (kACT), with no impact on the rate of cross-bridge tension redevelopment (kTR). Thus, the activation kinetics (kACT/kTR) that were reduced in DCM samples were restored for dATP to NF sample levels. dATP had little effect on relaxation. The rate of early slow-phase relaxation was slightly reduced with dATP, but its duration was not, nor was the fast-phase relaxation or times to 50 and 90% relaxation. Our findings suggest that myosin utilization of dATP improves cardiac myofibril contractile properties of naturally occurring DCM canine samples, restoring them to NF levels, without compromising relaxation. This suggests elevation of cardiac dATP is a promising approach for the treatment of DCM. PMID:26497964

  3. 2-Deoxyadenosine triphosphate restores the contractile function of cardiac myofibril from adult dogs with naturally occurring dilated cardiomyopathy.

    PubMed

    Cheng, Yuanhua; Hogarth, Kaley A; O'Sullivan, M Lynne; Regnier, Michael; Pyle, W Glen

    2016-01-01

    Dilated cardiomyopathy (DCM) is a major type of heart failure resulting from loss of systolic function. Naturally occurring canine DCM is a widely accepted experimental paradigm for studying human DCM. 2-Deoxyadenosine triphosphate (dATP) can be used by myosin and is a superior energy substrate over ATP for cross-bridge formation and increased systolic function. The objective of this study was to evaluate the beneficial effect of dATP on contractile function of cardiac myofibrils from dogs with naturally occurring DCM. We measured actomyosin NTPase activity and contraction/relaxation properties of isolated myofibrils from nonfailing (NF) and DCM canine hearts. NTPase assays indicated replacement of ATP with dATP significantly increased myofilament activity in both NF and DCM samples. dATP significantly improved maximal tension of DCM myofibrils to the NF sample level. dATP also restored Ca(2+) sensitivity of tension that was reduced in DCM samples. Similarly, dATP increased the kinetics of contractile activation (kACT), with no impact on the rate of cross-bridge tension redevelopment (kTR). Thus, the activation kinetics (kACT/kTR) that were reduced in DCM samples were restored for dATP to NF sample levels. dATP had little effect on relaxation. The rate of early slow-phase relaxation was slightly reduced with dATP, but its duration was not, nor was the fast-phase relaxation or times to 50 and 90% relaxation. Our findings suggest that myosin utilization of dATP improves cardiac myofibril contractile properties of naturally occurring DCM canine samples, restoring them to NF levels, without compromising relaxation. This suggests elevation of cardiac dATP is a promising approach for the treatment of DCM. Copyright © 2016 the American Physiological Society.

  4. Increased odds and predictive rates of MMPI-2-RF scale elevations in patients with psychogenic non-epileptic seizures and observed sex differences.

    PubMed

    Del Bene, Victor A; Arce Rentería, Miguel; Maiman, Moshe; Slugh, Mitch; Gazzola, Deana M; Nadkarni, Siddhartha S; Barr, William B

    2017-07-01

    The Minnesota Multiphasic Personality Inventory-2-Restructured Form (MMPI-2-RF) is a self-report instrument, previously shown to differentiate patients with epileptic seizures (ES) and psychogenic non-epileptic seizures (PNES). At present, the odds of MMPI-2-RF scale elevations in PNES patients, as well as the diagnostic predictive value of such scale elevations, remain largely unexplored. This can be of clinical utility, particularly when a diagnosis is uncertain. After looking at mean group differences, we applied contingency table derived odds ratios to a sample of ES (n=92) and PNES (n=77) patients from a video EEG (vEEG) monitoring unit. We also looked at the positive and negative predictive values (PPV, NPV), as well as the false discovery rate (FDR) and false omission rate (FOR) for scales found to have increased odds of elevation in PNES patients. This was completed for the overall sample, as well as the sample stratified by sex. The odds of elevations related to somatic concerns, negative mood, and suicidal ideation in the PNES sample ranged from 2 to 5 times more likely. Female PNES patients had 3-6 times greater odds of such scale elevations, while male PNES patients had odds of 5-15 times more likely. PPV rates ranged from 53.66% to 84.62%, while NPV rates ranged from 47.52% to 90.91%. FDR across scales ranged from 15.38% to 50%, while the FOR ranged from 9.09% to 52.47%. Consistent with prior research, PNES patients have greater odds of MMPI-2-RF scale elevations, particularly related to somatic concerns and mood disturbance. Female PNES patients endorsed greater emotional distress, including endorsement of suicide related items. Elevations of these scales could aid in differentiating PNES from ES patients, although caution is warranted due to the possibility of both false positives and the incorrect omissions of PNES cases. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. [Hearing the impact of MP3 on a survey of middle school students].

    PubMed

    Xu, Zhan; Li, Zonghua; Chen, Yang; He, Ya; Chunyu, Xiujie; Wang, Fangyuan; Zhang, Pengzhi; Gao, Lei; Qiu, Shuping; Liu, Shunli; Qiao, Li; Qiu, Jianhua

    2011-02-01

    To understand the usage of MP3 and effects on hearing of middle school students in Xi'an, and discuss controlling strategies. Stratified random cluster sampling method was used in the 1567 middle school students in Xi'an through questionnaire survey, ear examination and hearing examination, data were analysed by the SPSS13.0 statistical software. 1) The rate of holding MP3 in the middle school students was 85.2%. Average daily use time was (1.41 +/- 1.11) h. 2) The noise group of pure tone hearing threshold was significantly higher compared with the control group (P<0.01), and increased the detection rate of hearing loss with the increasing use of MP3. 3) The detection rate of symptoms increased with the increasing use of MP3. The usage of MP3 can harm hearing in middle school students, which can result in neurasthenic syndrome.

  6. Effect of Chronic Diseases on Work Productivity: A Propensity Score Analysis.

    PubMed

    Fouad, Ahmed Mahmoud; Waheed, Amani; Gamal, Amira; Amer, Shaimaa Ahmed; Abdellah, Rasha Farouk; Shebl, Fatma Mohamed

    2017-05-01

    The aim of this study was to evaluate the effect of chronic disease(s) on work productivity. Using the Health & Work Performance Questionnaire, information was collected from 516 workers on chronic disease status and work productivity. Propensity-score matching was performed to identify matched-pairs of workers. In the propensity-score matched sample, workers with chronic diseases were more likely to have increased absenteeism and presenteeism rates, 6.34 and 2.36 times the rates if no chronic diseases, respectively. In addition, they had greater odds for getting negative critical work incidents and less odds for positive incidents than none or balanced status. Multimorbidity showed more significant increase in absenteeism and presenteeism rates, as well as increased odds for excess negative critical work incidents. Chronic disease(s) can significantly reduce work productivity by increasing absenteeism, presenteeism, and net negative critical incidents.

  7. Laboratory Investigation on Physical and Mechanical Properties of Granite After Heating and Water-Cooling Treatment

    NASA Astrophysics Data System (ADS)

    Zhang, Fan; Zhao, Jianjian; Hu, Dawei; Skoczylas, Frederic; Shao, Jianfu

    2018-03-01

    High-temperature treatment may cause changes in physical and mechanical properties of rocks. Temperature changing rate (heating, cooling and both of them) plays an important role in those changes. Thermal conductivity tests, ultrasonic pulse velocity tests, gas permeability tests and triaxial compression tests are performed on granite samples after a heating and rapid cooling treatment in order to characterize the changes in physical and mechanical properties. Seven levels of temperature (from 25 to 900 °C) are used. It is found that the physical and mechanical properties of granite are significantly deteriorated by the thermal treatment. The porosity shows a significant increase from 1.19% at the initial state to 6.13% for samples heated to 900 °C. The increase in porosity is mainly due to three factors: (1) a large number of microcracks caused by the rapid cooling rate; (2) the mineral transformation of granite through high-temperature heating and water-cooling process; (3) the rapid cooling process causes the mineral particles to weaken. As the temperature of treatment increases, the thermal conductivity and P-wave velocity decrease while the gas permeability increases. Below 200 °C, the elastic modulus and cohesion increase with temperature increasing. Between 200 and 500 °C, the elastic modulus and cohesion have no obvious change with temperature. Beyond 500 °C, as the temperature increases, the elastic modulus and cohesion obviously decrease and the decreasing rate becomes slower with the increase in confining pressure. Poisson's ratio and internal frictional coefficient have no obvious change as the temperature increases. Moreover, there is a transition from a brittle to ductile behavior when the temperature becomes high. At 900 °C, the granite shows an obvious elastic-plastic behavior.

  8. Sociosexually unrestricted parents have more sons: a further application of the generalized Trivers-Willard hypothesis (gTWH).

    PubMed

    Kanazawa, Satoshi; Apari, Péter

    2009-01-01

    The generalized Trivers-Willard hypothesis (gTWH) proposes that parents who possess any heritable trait which increases male reproductive success at a greater rate than female reproductive success in a given environment will have a higher-than-expected offspring sex ratio, and parents who possess any heritable trait which increases the female reproductive success at a greater rate than male reproductive success in a given environment will have a lower-than-expected offspring sex ratio. One heritable trait which increases the reproductive success of sons much more than that of daughters is unrestricted sociosexual orientation. We therefore predict that parents with unrestricted sociosexual orientation (measured by the number of sexual partners, frequency of sex, and attitudes toward relationship commitment and sexual exclusivity) have a higher-than-expected offspring sex ratio (more sons). We analyse the US General Social Surveys and the National Longitudinal Study of Adolescent Health (Add Health), both with large nationally representative samples. Our analyses support the prediction from the gTWH. One standard deviation increase in unrestrictedness of sociosexual orientation increases the odds of having a son by 12-19% in the representative American samples.

  9. When Can Clades Be Potentially Resolved with Morphology?

    PubMed Central

    Bapst, David W.

    2013-01-01

    Morphology-based phylogenetic analyses are the only option for reconstructing relationships among extinct lineages, but often find support for conflicting hypotheses of relationships. The resulting lack of phylogenetic resolution is generally explained in terms of data quality and methodological issues, such as character selection. A previous suggestion is that sampling ancestral morphotaxa or sampling multiple taxa descended from a long-lived, unchanging lineage can also yield clades which have no opportunity to share synapomorphies. This lack of character information leads to a lack of ‘intrinsic’ resolution, an issue that cannot be solved with additional morphological data. It is unclear how often we should expect clades to be intrinsically resolvable in realistic circumstances, as intrinsic resolution must increase as taxonomic sampling decreases. Using branching simulations, I quantify intrinsic resolution across several models of morphological differentiation and taxonomic sampling. Intrinsically unresolvable clades are found to be relatively frequent in simulations of both extinct and living taxa under realistic sampling scenarios, implying that intrinsic resolution is an issue for morphology-based analyses of phylogeny. Simulations which vary the rates of sampling and differentiation were tested for their agreement to observed distributions of durations from well-sampled fossil records and also having high intrinsic resolution. This combination only occurs in those datasets when differentiation and sampling rates are both unrealistically high relative to branching and extinction rates. Thus, the poor phylogenetic resolution occasionally observed in morphological phylogenetics may result from a lack of intrinsic resolvability within groups. PMID:23638034

  10. Fetal Tissue Procurement for Karyotype Analysis: Clinician or Pathologist - Which is Better?

    PubMed

    Conant, Joanna L; Tang, Mary E; Waters, Brenda L

    2016-01-01

    Chromosomal abnormalities are detected in up to 13% of stillbirths and over 20% of those with developmental anomalies. These estimates may be low since up to 50% of samples fail to achieve a result due to microbial overgrowth or nonviability. Tissue for cytogenetics can be procured at bedside by the clinician or by the pathologist in the laboratory. With clinical collection, tissue is placed into culture media immediately, increasing chances of growth. However, collection competes for attention with other activities, which may result in microbial overgrowth or selection of maternal rather than fetal tissue. Laboratory procurement occurs in a controlled environment using sterile technique, but delay in collection may decrease viability. Our goal was to determine which collection method yields better results. We reviewed cases from 2007-2013 that had two samples submitted for cytogenetics, one from the clinician and one from the pathologist. Specimen source, delivery, collection, and culture setup times, harvest date, cell growth, microbial overgrowth, maternal contamination and final result were obtained from medical records and cytogenetic culture sheets. There was no difference in growth rate, maternal cell contamination, or reporting time between clinician- and pathologist-procured samples despite delay in collection time for laboratory samples. Clinical samples had more microbial overgrowth. Compared to samples collected at bedside, samples collected in the laboratory had a lower rate of microbial contamination with similar growth and maternal cell contamination rates, despite prolonged time to collection. Collecting samples both at bedside and in the laboratory is unnecessary.

  11. The effect of temperature on the extrinsic incubation period and infection rate of dengue virus serotype 2 infection in Aedes albopictus.

    PubMed

    Xiao, Fang-Zhen; Zhang, Yi; Deng, Yan-Qin; He, Si; Xie, Han-Guo; Zhou, Xiao-Nong; Yan, Yan-Sheng

    2014-11-01

    Dengue fever is an acute mosquito-borne viral disease caused by dengue virus (DENV). Temperature may affect the efficiency of the mosquito vectors in spreading DENV. Aedes albopictus mosquitoes were infected orally with a DENV2 suspension and incubated at different temperatures. Subsequently, DENV2 antigen was collected from salivary gland and thorax-abdomen samples on different days postinfection and tested using an immunofluorescence assay to determine the extrinsic incubation period and infection rate. As the temperature increased, the extrinsic DENV2 incubation period in Ae. albopictus gradually shortened, and infection rates showed a tendency to initially increase, followed by a subsequent decrease.

  12. Electroerosion of metal in aqueous solution for sample introduction into an inductively coupled plasma mass spectrometer

    NASA Astrophysics Data System (ADS)

    Goltz, Douglas; Boileau, Michael; Reinfelds, Gundars

    2003-07-01

    When high current (1-10 A cm -2) is applied between two conductive samples (metals) in aqueous solution, electroerosion occurs on the surface as a result of electrolysis and possibly collisions of dissolved ions with the metal surface. The power supply for the electroerosion apparatus in this work was a modified spark source unit. Current could be varied in intervals of 2.5, 5 and 10 A in either half-wave (unipolar) or full-wave (bipolar) output. The electroeroded metal forms a colloidal suspension in aqueous solution with particle sizes of the order of 1-10 μm and possibly larger. The suspension is readily dissolved using a small amount (100 μl) of concentrated acid (HCl or HNO 3) prior to analysis. Electroerosion of steel and brass in aqueous solution is described both for rapid sample dissolution and as a solid sampling approach for ICP-MS. Some of the electroerosion properties described in this paper include rates of erosion as a function of gap between the conductive samples and solution conductivity. Rates of electroerosion decreased from 120 to 30 μg s -1 as the gap was increased from 2 to 5 mm. Rates of electroerosion also increased significantly from 200 to 1000 μg s -1 as the conductivity of the electroerosion solution increased from 0.01 to 0.05 M NaCl. Interfacing the electroerosion apparatus to an ICP-MS was straight forward, as no special equipment was required. Therefore, the electroerosion apparatus can be used for rapid 'on-line' sample dissolution prior to introduction into an ICP. ICP-MS time profiles of selected metals in stainless steel 308L illustrate the behavior of 52Cr +, 55Mn + and 60Ni + during a typical electroerosion cycle. Aspiration of the colloidal suspension into the ICP did not appear to load the plasma significantly, however, all of the metals produced noisy signals (±10%). A glass concentric nebulizer was used without clogging, so it is likely that the heterogeneous nature of the colloidal suspension caused this effect.

  13. Colloid mobilization and heavy metal transport in the sampling of soil solution from Duckum soil in South Korea.

    PubMed

    Lee, Seyong; Ko, Il-Won; Yoon, In-Ho; Kim, Dong-Wook; Kim, Kyoung-Woong

    2018-03-24

    Colloid mobilization is a significant process governing colloid-associated transport of heavy metals in subsurface environments. It has been studied for the last three decades to understand this process. However, colloid mobilization and heavy metal transport in soil solutions have rarely been studied using soils in South Korea. We investigated the colloid mobilization in a variety of flow rates during sampling soil solutions in sand columns. The colloid concentrations were increased at low flow rates and in saturated regimes. Colloid concentrations increased 1000-fold higher at pH 9.2 than at pH 7.3 in the absence of 10 mM NaCl solution. In addition, those were fourfold higher in the absence than in the presence of the NaCl solution at pH 9.2. It was suggested that the mobility of colloids should be enhanced in porous media under the basic conditions and the low ionic strength. In real field soils, the concentrations of As, Cr, and Pb in soil solutions increased with the increase in colloid concentrations at initial momentarily changed soil water pressure, whereas the concentrations of Cd, Cu, Fe, Ni, Al, and Co lagged behind the colloid release. Therefore, physicochemical changes and heavy metal characteristics have important implications for colloid-facilitated transport during sampling soil solutions.

  14. Kinetics of red blood cell rouleaux formation studied by light scattering

    NASA Astrophysics Data System (ADS)

    Szołna-Chodór, Alicja; Bosek, Maciej; Grzegorzewski, Bronisław

    2015-02-01

    Red blood cell (RBC) rouleaux formation was experimentally studied using a light scattering technique. The suspensions of RBCs were obtained from the blood of healthy donors. Hematocrit of the samples was adjusted ranging from 1% to 4%. Measurements of the intensity of the coherent component of light scattered by the suspensions were performed and the scattering coefficient of the suspensions was determined. The number of RBCs per rouleaux was obtained using anomalous diffraction theory. The technique was used to show the effect of time, hematocrit, and sample thickness on the process. The number of cells per rouleaux first increases linearly, reaches a critical value at ˜3 cells per rouleaux, and then a further increase in the rouleaux size is observed. The kinetic constant of the rouleaux growth in the linear region is found to be independent of hematocrit. The aggregation rate increases as the sample thickness increases. The time at which the critical region appears strongly decreases as the hematocrit of the suspension increases.

  15. Effect of electrical stimulation and ageing period on alpaca (Vicugna pacos) meat and eating quality.

    PubMed

    Smith, M A; Bush, R D; van de Ven, R J; Hopkins, D L

    2016-01-01

    This study investigated the effects of using medium voltage (~300 V) electrical stimulation (ES) and ageing on alpaca meat. A total of 50 huacaya alpacas were distributed across three age groups (18, 24 and 36 months) and two genders (females and castrated males). At 24h post mortem the m. longissimus thoracis et lumborum (LL) and m. semimembranosus (SM) muscles were removed and aged for either 5 or 10 days. In comparison to non-ES samples, ES significantly reduced: LL purge values by 3.0% and LL shear force (SF) at 5 and 10 days (by 21.6N and ageing further reduced tenderness by 6.6N), and SM SF by 5.8 N with significant age effects observed in both ES and non-ES SM samples, such that SF increased by 0.53 N with each month increase in animal age. Consumers rated ES samples higher on tenderness, juiciness, flavour and overall rating. ES and ageing of alpaca carcasses are recommended. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Erosion of water-based fracturing fluid containing particles in a sudden contraction of horizontal pipe

    NASA Astrophysics Data System (ADS)

    Cheng, Jiarui; Cao, Yinping; Dou, Yihua; Li, Zhen

    2017-10-01

    A lab experiment was carried out to study the effects of pipe flow rate, particle concentration and pipe inner diameter ratio on proppant erosion of the reducing wall in hydraulic fracturing. The results show that the erosion rate and erosion distribution are different not only in radial direction but also in circumferential direction of the sample. The upper part of sample always has a minimum erosion rate and erosion area. Besides, the erosion rate of reducing wall is most affected by fluid flow velocity, and the erosion area is most sensitive to the change in the diameter ratio. Meanwhile, the erosion rate of reducing wall in crosslinked fracturing fluid is mainly determined by the fluid flowing state due to the high viscosity of the liquid. In general, the increase in flow velocity and diameter ratio not only cause the expansion of erosion-affected flow region in sudden contraction section, but also lead to more particles impact the wall.

  17. Static Corrosion Test of Porous Iron Material with Polymer Coating

    NASA Astrophysics Data System (ADS)

    Markušová-Bučková, Lucia; Oriňaková, Renáta; Oriňak, Andrej; Gorejová, Radka; Kupková, Miriam; Hrubovčáková, Monika; Baláž, Matej; Kováľ, Karol

    2016-12-01

    At present biodegradable implants received increased attention due to their use in various fields of medicine. This work is dedicated to testing of biodegradable materials which could be used as bone implants. The samples were prepared from the carbonyl iron powder by replication method and surface polymer film was produced through sol-gel process. Corrosion testing was carried out under static conditions during 12 weeks in Hank's solution. The quantity of corrosion products increased with prolonging time of static test as it can be concluded from the results of EDX analysis. The degradation of open cell materials with polyethylene glycol coating layer was faster compared to uncoated Fe sample. Also the mass losses were higher for samples with PEG coating. The polymer coating brought about the desired increase in degradation rate of porous iron material.

  18. Surgical Space Suits Increase Particle and Microbiological Emission Rates in a Simulated Surgical Environment.

    PubMed

    Vijaysegaran, Praveen; Knibbs, Luke D; Morawska, Lidia; Crawford, Ross W

    2018-05-01

    The role of space suits in the prevention of orthopedic prosthetic joint infection remains unclear. Recent evidence suggests that space suits may in fact contribute to increased infection rates, with bioaerosol emissions from space suits identified as a potential cause. This study aimed to compare the particle and microbiological emission rates (PER and MER) of space suits and standard surgical clothing. A comparison of emission rates between space suits and standard surgical clothing was performed in a simulated surgical environment during 5 separate experiments. Particle counts were analyzed with 2 separate particle counters capable of detecting particles between 0.1 and 20 μm. An Andersen impactor was used to sample bacteria, with culture counts performed at 24 and 48 hours. Four experiments consistently showed statistically significant increases in both PER and MER when space suits are used compared with standard surgical clothing. One experiment showed inconsistent results, with a trend toward increases in both PER and MER when space suits are used compared with standard surgical clothing. Space suits cause increased PER and MER compared with standard surgical clothing. This finding provides mechanistic evidence to support the increased prosthetic joint infection rates observed in clinical studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. The demand for health insurance coverage by low-income workers: can reduced premiums achieve full coverage?

    PubMed

    Chernew, M; Frick, K; McLaughlin, C G

    1997-10-01

    To assess the degree to which premium reductions will increase the participation in employer-sponsored health plans by low-income workers who are employed in small businesses. Sample of workers in small business (25 or fewer employees) in seven metropolitan areas. The data were gathered as part of the Small Business Benefits Survey, a telephone survey of small business conducted between October 1992 and February 1993. Probit regressions were used to estimate the demand for health insurance coverage by low-income workers. Predictions based on these findings were made to assess the extent to which premium reductions might increase coverage rates. Workers included in the sample were selected, at random, from a randomly generated set of firms drawn from Dun and Bradstreet's DMI (Dun's Market Inclusion). The response rate was 81 percent. Participation in employer-sponsored plans is high when coverage is offered. However, even when coverage is offered to employees who have no other source of insurance, participation is not universal. Although premium reductions will increase participation in employer-sponsored plans, even large subsidies will not induce all workers to participate in employer-sponsored plans. For workers eligible to participate, subsidies as high as 75 percent of premiums are estimated to increase participation rates from 89.0 percent to 92.6 percent. For workers in firms that do not sponsor plans, similar subsidies are projected to achieve only modest increases in coverage above that which would be observed if the workers had access to plans at unsubsidized, group market rates. Policies that rely on voluntary purchase of coverage to reduce the number of uninsured will have only modest success.

  20. Mortality Among Patients Hospitalized With Heart Failure and Diabetes Mellitus: Results From the National Inpatient Sample 2000 to 2010.

    PubMed

    Win, Theingi Tiffany; Davis, Herbert T; Laskey, Warren K

    2016-05-01

    Case fatality and hospitalization rates for US patients with heart failure (HF) have steadily decreased during the past several decades. Diabetes mellitus (DM), a risk factor for, and frequent coexisting condition with, HF continues to increase in the general population. We used the National Inpatient Sample to estimate overall as well as age-, sex-, and race/ethnicity-specific trends in HF hospitalizations, DM prevalence, and in-hospital mortality among 2.5 million discharge records from 2000 to 2010 with HF as primary discharge diagnosis. Multivariable logistic and Poisson regression were used to assess the impact of the above demographic characteristics on in-hospital mortality. Age-standardized hospitalizations decreased significantly in HF overall and in HF with DM. Age-standardized in-hospital mortality with HF declined from 2000 to 2010 (4.57% to 3.09%, Ptrend<0.0001), whereas DM prevalence in HF increased (38.9% to 41.9%, Ptrend<0.0001) as did comorbidity burden. Age-standardized in-hospital mortality in HF with DM also decreased significantly (3.53% to 2.27%, Ptrend<0.0001). After adjusting for year, age, and comorbid burden, males remained at 17% increased risk versus females, non-Hispanics remained at 12% increased risk versus Hispanics, and whites had a 30% higher mortality versus non-white minorities. Absolute mortality rates were lower in younger versus older patients, although the rate of decline was attenuated in younger patients. In-hospital mortality in HF patients with DM significantly decreased during the past decade, despite increases in DM prevalence and comorbid conditions. Mortality rate decreases among younger patients were significantly attenuated, and mortality disparities remain among important demographic subgroups. © 2016 American Heart Association, Inc.

  1. Enhanced cortisol production rates, free cortisol, and 11beta-HSD-1 expression correlate with visceral fat and insulin resistance in men: effect of weight loss.

    PubMed

    Purnell, Jonathan Q; Kahn, Steven E; Samuels, Mary H; Brandon, David; Loriaux, D Lynn; Brunzell, John D

    2009-02-01

    Controversy exists as to whether endogenous cortisol production is associated with visceral obesity and insulin resistance in humans. We therefore quantified cortisol production and clearance rates, abdominal fat depots, insulin sensitivity, and adipocyte gene expression in a cohort of 24 men. To test whether the relationships found are a consequence rather than a cause of obesity, eight men from this larger group were studied before and after weight loss. Daily cortisol production rates (CPR), free cortisol levels (FC), and metabolic clearance rates (MCR) were measured by stable isotope methodology and 24-h sampling; intra-abdominal fat (IAF) and subcutaneous fat (SQF) by computed tomography; insulin sensitivity (S(I)) by frequently sampled intravenous glucose tolerance test; and adipocyte 11beta-hydroxysteroid dehydrogenase-1 (11beta-HSD-1) gene expression by quantitative RT-PCR from subcutaneous biopsies. Increased CPR and FC correlated with increased IAF, but not SQF, and with decreased S(I). Increased 11beta-HSD-1 gene expression correlated with both IAF and SQF and with decreased S(I). With weight loss, CPR, FC, and MCR did not change compared with baseline; however, with greater loss in body fat than lean mass during weight loss, both CPR and FC increased proportionally to final fat mass and IAF and 11beta-HSD-1 decreased compared with baseline. These data support a model in which increased hypothalamic-pituitary-adrenal activity in men promotes selective visceral fat accumulation and insulin resistance and may promote weight regain after diet-induced weight loss, whereas 11beta-HSD-1 gene expression in SQF is a consequence rather than cause of adiposity.

  2. Evaluation of process errors in bed load sampling using a Dune Model

    USGS Publications Warehouse

    Gomez, Basil; Troutman, Brent M.

    1997-01-01

    Reliable estimates of the streamwide bed load discharge obtained using sampling devices are dependent upon good at-a-point knowledge across the full width of the channel. Using field data and information derived from a model that describes the geometric features of a dune train in terms of a spatial process observed at a fixed point in time, we show that sampling errors decrease as the number of samples collected increases, and the number of traverses of the channel over which the samples are collected increases. It also is preferable that bed load sampling be conducted at a pace which allows a number of bed forms to pass through the sampling cross section. The situations we analyze and simulate pertain to moderate transport conditions in small rivers. In such circumstances, bed load sampling schemes typically should involve four or five traverses of a river, and the collection of 20–40 samples at a rate of five or six samples per hour. By ensuring that spatial and temporal variability in the transport process is accounted for, such a sampling design reduces both random and systematic errors and hence minimizes the total error involved in the sampling process.

  3. Applying the Paris System for Reporting Urine Cytology Increases the Rate of Atypical Urothelial Cells in Benign Cases: A Need for Patient Management Recommendations.

    PubMed

    Granados, Rosario; Duarte, Joanny A; Corrales, Teresa; Camarmo, Encarnación; Bajo, Paloma

    2017-01-01

    The Paris System (TPS) for reporting urinary cytology attempts to unify the terminology in this field. To analyze the impact of adopting TPS by measuring nomenclature agreement and cytohistological correlation. Voided urine liquid-based cytology samples corresponding to 149 biopsy-proven cases (76 high-grade carcinomas, 40 low-grade carcinomas, and 33 benign lesions), were reclassified by the same pathologist using TPS. Diagnostic agreement and sensitivity for both nomenclature systems was measured. When using TPS, the rate of atypical samples increased 8 times (from 3 to 24.2%) in benign cases, 10 times (from 2.5 to 25%) in low-grade carcinomas, and 2.4 times (from 6.6 to 15.8%) in high-grade carcinomas. The false-positive rate (abnormal cytology in negative or low-grade carcinoma cases) increased from 11 to 34.2%. Sensitivity was higher (63 vs. 49%) with TPS at the expense of a lower specificity (73 vs. 91%). The agreement between both nomenclatures was moderate for negative and high-grade carcinoma cases (k = 0.42 and 0.56, respectively) and weak for low-grade tumors (k = 0.35). Adopting TPS for reporting urine cytology results in a considerable increase in atypical diagnoses, improving sensitivity but lowering specificity. Appropriate management recommendations for patients with an atypical cytological diagnosis are required. © 2016 S. Karger AG, Basel.

  4. Comparison of physician referral and insurance claims data-based risk prediction as approaches to identify patients for care management in primary care: an observational study.

    PubMed

    Freund, Tobias; Gondan, Matthias; Rochon, Justine; Peters-Klimm, Frank; Campbell, Stephen; Wensing, Michel; Szecsenyi, Joachim

    2013-10-20

    Primary care-based care management (CM) could reduce hospital admissions in high-risk patients. Identification of patients most likely to benefit is needed as resources for CM are limited. This study aimed to compare hospitalization and mortality rates of patients identified for CM either by treating primary care physicians (PCPs) or predictive modelling software for hospitalization risk (PM). In 2009, a cohort of 6,026 beneficiaries of a German statutory health insurance served as a sample for patient identification for CM by PCPs or commercial PM (CSSG 0.8, Verisk Health). The resulting samples were compared regarding hospitalization and mortality rates in 2010 and in the two year period before patient selection. No CM-intervention was delivered until the end of 2010 and PCPs were blinded for the assessment of hospitalization rates. In 2010, hospitalization rates of PM-identified patients were 80% higher compared to PCP-identified patients. Mortality rates were also 8% higher in PM-identified patients if compared to PCP-identified patients (10% vs. 2%). The hospitalization rate of patients independently identified by both PM and PCPs was numerically between PM- and PCP-identified patients. Time trend between 2007 and 2010 showed decreasing hospitalization rates in PM-identified patients (-15% per year) compared to increasing rates in PCP-identified patients (+34% per year). PM identified patients with higher hospitalization and mortality rates compared to PCP-referred patients. But the latter showed increasing hospitalization rates over time thereby suggesting that PCPs may be able to predict future deterioration in patients with relatively good current health status. These patients may most likely benefit from preventive services like CM.

  5. Benefits and Limitations of Low-kV Macromolecular Imaging of Frozen-Hydrated Biological Samples

    PubMed Central

    Majorovits, Endre; Angert, Isabel; Kaiser, Ute; Schröder, Rasmus R.

    2016-01-01

    Object contrast is one of the most important parameters of macromolecular imaging. Low-voltage transmission electron microscopy has shown an increased atom contrast for carbon materials, indicating that amplitude contrast contributions increase at a higher rate than phase contrast and inelastic scattering. Here, we studied image contrast using ice-embedded tobacco mosaic virus particles as test samples at 20–80 keV electron energy. The particles showed the expected increase in contrast for lower energies, but at the same time the 2.3-nm-resolution measure decayed more rapidly. We found a pronounced signal loss below 60 keV, and therefore we conclude that increased inelastic scattering counteracts increased amplitude contrast. This model also implies that as long as the amplitude contrast does not increase with resolution, beam damage and multiple scattering will always win over increased contrast at the lowest energies. Therefore, we cannot expect that low-energy imaging of conventionally prepared samples would provide better data than state-of-the-art 200–300 keV imaging. PMID:26910420

  6. [Effect of UV Light Radiation on the Coagulation of Chlorella and Its Mechanism].

    PubMed

    Wang, Wen-dong; Zhang, Ke; Xu, Hong-bin; Liu, Guo-qi

    2016-01-15

    Considering algae were difficult to be effectively removed in conventional water treatment process, UV radiation was used to enhance the coagulation of algae in this study. The results showed that with the increase of radiation time, the removal rates of both algae and turbidity experienced a decrease after an increase, and reached their maximum values at 50 min. When the dosage of PAC was 5 mg x L(-1), the removal rates of algae and turbidity of the radiated sample were 20.1% and 18% higher than the blank sample, respectively. When pH ranged from 6 to 9, the coagulation efficiency varied little. At pH 8 and with a radiation time of 50 min, the removal rates of algae and turbidity reached 93.5% and 90.6%, respectively. Meanwhile, the Zeta potential reached the maximum, and the algae generated extracellular organic matter, which favored the subsequent coagulation. After radiated for 60 min, the algal cells was destroyed, leading to a release of intracellular organic matter into the solution. Accordingly, the Zeta potential decreased, which had a negative effect on the subsequent coagulation process.

  7. Investigation of Legionella Contamination in Bath Water Samples by Culture, Amoebic Co-Culture, and Real-Time Quantitative PCR Methods.

    PubMed

    Edagawa, Akiko; Kimura, Akio; Kawabuchi-Kurata, Takako; Adachi, Shinichi; Furuhata, Katsunori; Miyamoto, Hiroshi

    2015-10-19

    We investigated Legionella contamination in bath water samples, collected from 68 bathing facilities in Japan, by culture, culture with amoebic co-culture, real-time quantitative PCR (qPCR), and real-time qPCR with amoebic co-culture. Using the conventional culture method, Legionella pneumophila was detected in 11 samples (11/68, 16.2%). Contrary to our expectation, the culture method with the amoebic co-culture technique did not increase the detection rate of Legionella (4/68, 5.9%). In contrast, a combination of the amoebic co-culture technique followed by qPCR successfully increased the detection rate (57/68, 83.8%) compared with real-time qPCR alone (46/68, 67.6%). Using real-time qPCR after culture with amoebic co-culture, more than 10-fold higher bacterial numbers were observed in 30 samples (30/68, 44.1%) compared with the same samples without co-culture. On the other hand, higher bacterial numbers were not observed after propagation by amoebae in 32 samples (32/68, 47.1%). Legionella was not detected in the remaining six samples (6/68, 8.8%), irrespective of the method. These results suggest that application of the amoebic co-culture technique prior to real-time qPCR may be useful for the sensitive detection of Legionella from bath water samples. Furthermore, a combination of amoebic co-culture and real-time qPCR might be useful to detect viable and virulent Legionella because their ability to invade and multiply within free-living amoebae is considered to correlate with their pathogenicity for humans. This is the first report evaluating the efficacy of the amoebic co-culture technique for detecting Legionella in bath water samples.

  8. Comparison between single PCR and nested PCR in detection of human papilloma viruses in paraffin-embedded OSCC and fresh oral mucosa.

    PubMed

    Jalouli, Miranda; Jalouli, Jamshid; Ibrahim, Salah O; Hirsch, Jan-Michaél; Sand, Lars

    2015-01-01

    Infection with human papilloma virus (HPV) has been implicated as one of the risk factors for the development of oropharyngeal cancer. Many different HPV tests exist, and information regarding their specific technical, analytical, and clinical properties is increasing. This study aimed to compare the level of detection of HPV using two reliable polymerase chain reaction (PCR) methods, nested PCR (NPCR) and single PCR (SPCR), in archival paraffin-embedded oral squamous cell carcinoma (OSCC) samples and fresh oral mucosa specimens. The presence of HPV genome in two groups of tissue samples was analyzed: (i) 57 paraffin-embedded OSCC samples from Sudan and (ii) eight healthy fresh oral mucosal samples from Swedish volunteers. The specimens were tested by SPCR with primer pair MY9/MY11 and NPCR using GP5+/GP6+ primer sets. Eighteen (32%) out of the 57 paraffin-embedded OSCC samples, and five (62%) out of the eight fresh clinically healthy samples were found to be HPV-positive with NPCR. With SPCR, four (7%) out of the paraffin-embedded OSCC samples were HPV-positive. A statistically significant difference between HPV-positive and -negative samples was found when comparing NPCR and SPCR in OSCC and fresh oral mucosa (p<0.0001). The comparative test between SPCR and NPCR showed 100% sensitivity and 69% specificity for OSCC. The use of the GP5+/GP6+ nested PCR increased the positivity rate, efficiency rate and sensitivity of HPV detection in oral samples significantly and should be considered as the method of choice. Copyright © 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  9. Investigation of Legionella Contamination in Bath Water Samples by Culture, Amoebic Co-Culture, and Real-Time Quantitative PCR Methods

    PubMed Central

    Edagawa, Akiko; Kimura, Akio; Kawabuchi-Kurata, Takako; Adachi, Shinichi; Furuhata, Katsunori; Miyamoto, Hiroshi

    2015-01-01

    We investigated Legionella contamination in bath water samples, collected from 68 bathing facilities in Japan, by culture, culture with amoebic co-culture, real-time quantitative PCR (qPCR), and real-time qPCR with amoebic co-culture. Using the conventional culture method, Legionella pneumophila was detected in 11 samples (11/68, 16.2%). Contrary to our expectation, the culture method with the amoebic co-culture technique did not increase the detection rate of Legionella (4/68, 5.9%). In contrast, a combination of the amoebic co-culture technique followed by qPCR successfully increased the detection rate (57/68, 83.8%) compared with real-time qPCR alone (46/68, 67.6%). Using real-time qPCR after culture with amoebic co-culture, more than 10-fold higher bacterial numbers were observed in 30 samples (30/68, 44.1%) compared with the same samples without co-culture. On the other hand, higher bacterial numbers were not observed after propagation by amoebae in 32 samples (32/68, 47.1%). Legionella was not detected in the remaining six samples (6/68, 8.8%), irrespective of the method. These results suggest that application of the amoebic co-culture technique prior to real-time qPCR may be useful for the sensitive detection of Legionella from bath water samples. Furthermore, a combination of amoebic co-culture and real-time qPCR might be useful to detect viable and virulent Legionella because their ability to invade and multiply within free-living amoebae is considered to correlate with their pathogenicity for humans. This is the first report evaluating the efficacy of the amoebic co-culture technique for detecting Legionella in bath water samples. PMID:26492259

  10. The effects of cooling rates and type of freezing extenders on cryosurvival of rat sperm

    PubMed Central

    Varisli, Omer; Scott, Hollie; Agca, Cansu; Agca, Yuksel

    2013-01-01

    Cryopreservation of rat sperm is very challenging due to its sensitivity to various stress factors. The objective of this study was to determine the optimal cooling rate and extender for epididymal sperm of outbred Sprague Dawley (SD) and inbred Fischer 344 (F344) rat strains. The epididymal sperm from 10–12 weeks old sexually mature SD and F344 strains were suspended in five different freezing extenders, namely HEPES buffered Tyrode’s lactate (TL-HEPES), modified Kreb’s Ringer bicarbonate (mKRB), 3% dehydrated skim milk (SM), Salamon’s Tris-citrate (TRIS), and tes/tris (TES). All extenders contained 20% egg yolk, 0.75% Equex Paste and 0.1 M raffinose or 0.1 M sucrose. The sperm samples in each extender were cooled to 4°C and held for 45 min for equilibration before freezing. The equilibrated sperm samples in each extender were placed onto a shallow quartz dish inserted into Linkam Cryostage (BCS 196). The samples were then cooled to a final temperature of −150 °C by using various cooling rates (10, 40, 70, and 100 °C/min). For thawing, the quartz dish containing the sperm samples were rapidly removed from the Linkam cryo-stage and placed on a 37 °C slide warmer and held for 1 min before motility analysis. Sperm membrane and acrosomal integrity and mitochondrial membrane potential (MMP) were assessed by SYBR-14/Propidium iodide, Alexa Fluor-488-PNA conjugate and JC-1, respectively. The total motility, acrosomal integrity, membrane integrity and MMP values were compared among cooling rates and extenders. Both cooling rate and type of extender had significant effect on cryosurvival (P<0.05). Sperm motility increased as cooling rate was increased for both strains (P<0.05). Highest cryosurvival was achieved when 100 °C/min cooling rate was used in combination with TES extender containing 20% egg yolk, 0.75% Equex paste and either 0.1 M sucrose or raffinose (P < 0.05). This study showed that TES extender containing 0.1 M raffinose or sucrose with 70 °C /min and 100 °C /min cooling rate improved post-thaw motility of rat sperm. PMID:23727068

  11. GBM Observations of Terrestrial Gamma-Ray Flashes

    NASA Technical Reports Server (NTRS)

    Briggs, M. S.; Fishman, G. J.; Connaughton, V.; Bhat, P. N.; Paciesas, W. S.; Preece, R. D.; Wilson-Hodge, C.; Chaplin, V. L.; Kippen, R. M.; vonKienlin, A.; hide

    2010-01-01

    The TGF detection rate of Gamma-ray Burst Monitor (GBM) has been increased twice since launch. The most recent improvement is from a new operating mode in which data for individual photons are down-linked for selected portions of the orbit, enabling a more sensitive ground-based search for TGFs. The new search has increased the TGF detection rate and is finding TGFs more than five times fainter than the TGFs of the previous GBM sample. We summarize the properties of the original GBM TGF sample and compare to the less intense TGFs now being detected. In addition to gamma-ray TGFs, GBM is observing distant TGFs from the propagation of charged particles along geomagnetic field lines. Strong 511 keV annihilation lines have been observed, demonstrating that both electrons and positrons are present in the particle beams. Spectral fits to these electron/positron TGFs will be shown.

  12. EFFECT OF MASSIVE NEUTRON EXPOSURE ON THE DISTORTION OF REACTOR GRAPHITE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helm, J.W.; Davidson, J.M.

    1963-05-28

    Distortion of reactor-grade graphites was studied at varying neutron exposures ranging up to 14 x 10/sup 21/ neutrons per cm/sup 2/ (nvt)/sup */ at temperatures of irradiation ranging from 425 to 800 deg C. This exposure level corresponds to approximately 100,000 megawatt days per adjacent ton of fuel (Mwd/ At) in a graphite-moderated reactor. A conventionalcoke graphite, CSF, and two needle-coke graphites, NC-7 and NC-8, were studied. At all temperatures of irradiation the contraction rate of the samples cut parallel to the extrusion axis increased with increasing neutron exposure. For parallel samples the needle- coke graphites and the CSF graphitemore » contracted approximately the same amount. In the transverse direction the rate of cortraction at the higher irradiation temperntures appeared to be decreasing. Volume contractions derived from the linear contractions are discussed. (auth)« less

  13. Variations in Belowground Carbon Storage and Soil CO2 Flux Rates along a Wet Tropical Climate Gradient

    Treesearch

    Megan McGroddy; Whendee L. Silver

    2000-01-01

    We used a humid tropical elevation gradient to examine the relationships among climate, edaphic conditions, belowground carbon storage, and soil respiration rates. We also compared open and closed canopy sites to increase the range of microclimate conditions sampled along the gradient, and determine the effects of canopy openings on C and P storage, and C dynamics....

  14. Sample size re-assessment leading to a raised sample size does not inflate type I error rate under mild conditions.

    PubMed

    Broberg, Per

    2013-07-19

    One major concern with adaptive designs, such as the sample size adjustable designs, has been the fear of inflating the type I error rate. In (Stat Med 23:1023-1038, 2004) it is however proven that when observations follow a normal distribution and the interim result show promise, meaning that the conditional power exceeds 50%, type I error rate is protected. This bound and the distributional assumptions may seem to impose undesirable restrictions on the use of these designs. In (Stat Med 30:3267-3284, 2011) the possibility of going below 50% is explored and a region that permits an increased sample size without inflation is defined in terms of the conditional power at the interim. A criterion which is implicit in (Stat Med 30:3267-3284, 2011) is derived by elementary methods and expressed in terms of the test statistic at the interim to simplify practical use. Mathematical and computational details concerning this criterion are exhibited. Under very general conditions the type I error rate is preserved under sample size adjustable schemes that permit a raise. The main result states that for normally distributed observations raising the sample size when the result looks promising, where the definition of promising depends on the amount of knowledge gathered so far, guarantees the protection of the type I error rate. Also, in the many situations where the test statistic approximately follows a normal law, the deviation from the main result remains negligible. This article provides details regarding the Weibull and binomial distributions and indicates how one may approach these distributions within the current setting. There is thus reason to consider such designs more often, since they offer a means of adjusting an important design feature at little or no cost in terms of error rate.

  15. Using e-mail recruitment and an online questionnaire to establish effect size: A worked example.

    PubMed

    Kirkby, Helen M; Wilson, Sue; Calvert, Melanie; Draper, Heather

    2011-06-09

    Sample size calculations require effect size estimations. Sometimes, effect size estimations and standard deviation may not be readily available, particularly if efficacy is unknown because the intervention is new or developing, or the trial targets a new population. In such cases, one way to estimate the effect size is to gather expert opinion. This paper reports the use of a simple strategy to gather expert opinion to estimate a suitable effect size to use in a sample size calculation. Researchers involved in the design and analysis of clinical trials were identified at the University of Birmingham and via the MRC Hubs for Trials Methodology Research. An email invited them to participate.An online questionnaire was developed using the free online tool 'Survey Monkey©'. The questionnaire described an intervention, an electronic participant information sheet (e-PIS), which may increase recruitment rates to a trial. Respondents were asked how much they would need to see recruitment rates increased by, based on 90%. 70%, 50% and 30% baseline rates, (in a hypothetical study) before they would consider using an e-PIS in their research.Analyses comprised simple descriptive statistics. The invitation to participate was sent to 122 people; 7 responded to say they were not involved in trial design and could not complete the questionnaire, 64 attempted it, 26 failed to complete it. Thirty-eight people completed the questionnaire and were included in the analysis (response rate 33%; 38/115). Of those who completed the questionnaire 44.7% (17/38) were at the academic grade of research fellow 26.3% (10/38) senior research fellow, and 28.9% (11/38) professor. Dependent upon the baseline recruitment rates presented in the questionnaire, participants wanted recruitment rate to increase from 6.9% to 28.9% before they would consider using the intervention. This paper has shown that in situations where effect size estimations cannot be collected from previous research, opinions from researchers and trialists can be quickly and easily collected by conducting a simple study using email recruitment and an online questionnaire. The results collected from the survey were successfully used in sample size calculations for a PhD research study protocol.

  16. The evolutionary rate dynamically tracks changes in HIV-1 epidemics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maljkovic-berry, Irina; Athreya, Gayathri; Daniels, Marcus

    Large-sequence datasets provide an opportunity to investigate the dynamics of pathogen epidemics. Thus, a fast method to estimate the evolutionary rate from large and numerous phylogenetic trees becomes necessary. Based on minimizing tip height variances, we optimize the root in a given phylogenetic tree to estimate the most homogenous evolutionary rate between samples from at least two different time points. Simulations showed that the method had no bias in the estimation of evolutionary rates and that it was robust to tree rooting and topological errors. We show that the evolutionary rates of HIV-1 subtype B and C epidemics have changedmore » over time, with the rate of evolution inversely correlated to the rate of virus spread. For subtype B, the evolutionary rate slowed down and tracked the start of the HAART era in 1996. Subtype C in Ethiopia showed an increase in the evolutionary rate when the prevalence increase markedly slowed down in 1995. Thus, we show that the evolutionary rate of HIV-1 on the population level dynamically tracks epidemic events.« less

  17. From DSM-IV to DSM-5 alcohol use disorder: an overview of epidemiological data.

    PubMed

    Bartoli, Francesco; Carrà, Giuseppe; Crocamo, Cristina; Clerici, Massimo

    2015-02-01

    The fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) has made several changes to criteria for alcohol use disorder (AUD). The objective of this systematic review is to assess if new DSM-5 diagnostic criteria will increase the prevalence rates of AUD in clinical and non-clinical samples as compared with DSM-IV criteria. We searched PubMed, Scopus, and PsycINFO (via ProQuest) electronic databases, with no language restrictions. We included studies with data available on both DSM-IV (and DSM-IV-TR) and DSM-5 AUD in samples of adults, estimating from each study an expected increase in prevalence rates with relevant 95% confidence intervals (CIs). Twelve studies were included in this review. Seven studies showed an increase, two no substantial difference, and three a decrease in AUD prevalence according to DSM-5 diagnostic criteria, with differences in rates (95% CIs) varying between -12.4% (-27.4 to +5.6%) and +61.3% (+46.7 to +77.3%). Additional analyses provided confirmatory results. DSM-5 diagnostic criteria seem to inflate prevalence rates of AUD as compared with DSM-IV. The increasing likelihood of a DSM-5 AUD diagnosis may be explained by the amount of DSM-IV 'diagnostic orphans' which are more prevalent than DSM-IV single-criterion alcohol abuse individuals. Further research should be aimed to study if similar trends are detectable also for other substance use disorders that experienced similar changes in DSM-5 diagnostic criteria. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Psychological distress, self-harming behavior, and suicidal tendencies in adults with disorders of sex development.

    PubMed

    Schützmann, Karsten; Brinkmann, Lisa; Schacht, Melanie; Richter-Appelt, Hertha

    2009-02-01

    Evaluation of psychological distress has received relatively little attention in research on persons with disorders of sex development (DSD). Results of previous studies varied considerably, but most studies did not find increased levels of psychological distress. We conducted a pilot study based on a sample of 37 persons with diverse forms of DSD recruited via various strategies. The Brief Symptom Inventory (BSI) was used to assess self-reported psychological distress. Psychological distress varied broadly across all diagnostic subgroups. Overall, the BSI Global Severity Index indicated higher distress in the sample of persons with DSD compared to a non-clinical norm population of women, with an effect size of d = 0.67. According to predefined BSI criteria, 59% of participants were classified as a clinical case. Self-harming behavior and suicidal tendencies were also assessed and compared to a community based sample of women, including subgroups of traumatized women with a history of physical or sexual abuse. The prevalence rates of self-harming behavior and suicidal tendencies in the DSD sample exceeded the rates of the non-traumatized comparison subgroup, with rates comparable to the traumatized comparison groups of women with physical or sexual abuse. As possible explanations for the higher distress found here compared to most previous studies, differences in measures and sample recruitment are discussed. Our results suggest that adults with DSD are markedly psychologically distressed with rates of suicidal tendencies and self-harming behavior on a level comparable to non-DSD women with a history of physical or sexual abuse, but sample recruitment procedures do not permit a firm generalization.

  19. Temperature influence on the fast pyrolysis of manure samples: char, bio-oil and gases production

    NASA Astrophysics Data System (ADS)

    Fernandez-Lopez, Maria; Anastasakis, Kostas; De Jong, Wiebren; Valverde, Jose Luis; Sanchez-Silva, Luz

    2017-11-01

    Fast pyrolysis characterization of three dry manure samples was studied using a pyrolyzer. A heating rate of 600°C/s and a holding time of 10 s were selected to reproduce industrial conditions. The effect of the peak pyrolysis temperature (600, 800 and 1000°C) on the pyrolysis product yield and composition was evaluated. Char and bio-oil were gravimetrically quantified. Scanning electron microscopy (SEM) was used to analyse the char structure. H2, CH4, CO and CO2 were measured by means of gas chromatography (GC). A decrease in the char yield and an increase of the gas yield were observed when temperature increased. From 800°C on, it was observed that the char yield of samples Dig R and SW were constant, which indicated that the primary devolatilization reactions stopped. This fact was also corroborated by GC analysis. The bio-oil yield slightly increased with temperature, showing a maximum of 20.7 and 27.8 wt.% for samples Pre and SW, respectively, whereas sample Dig R showed a maximum yield of 16.5 wt.% at 800°C. CO2 and CO were the main released gases whereas H2 and CH4 production increased with temperature. Finally, an increase of char porosity was observed with temperature.

  20. Detection of JAK2 V617F mutation increases the diagnosis of myeloproliferative neoplasms

    PubMed Central

    ZHANG, SHU-PENG; LI, HUI; LAI, REN-SHENG

    2015-01-01

    The Janus kinase (JAK)2 gene, which is located on chromosome 9p24, is involved in the signaling transduction pathways of the hematopoietic and immune system. Mutations in the JAK2 gene have served as disease markers for myeloproliferative neoplasms (MPNs). The aim of the present study was to investigate the occurrence of the JAK2 gene mutation in 140 clinical samples, and to evaluate its clinical significance in MPNs and other hematological diseases. Genomic DNA was extracted from the peripheral blood leukocytes or bone marrow karyocytes of 140 clinical samples, which included 130 patients with various types of hematological disease and 10 control patients. In addition, exons 12 and 14 of the JAK2 gene were analyzed by direct sequencing and the mutation rates of various MPN subtypes were evaluated. Of the 140 samples, exons 12 and 14 were tested in 74 samples, however, exon 14 only was tested in 66 samples. No mutations were identified in exon 12. The V617F mutation rate in polycythemia vera was 82.1% (23/28), and the mutation rates in essential thrombocythemia histiocytosis, primary myelofibrosis and other MPNs were 53.1% (17/32), 40.0% (4/10) and 60.0% (6/10), respectively. Therefore, the total mutation rate of the JAK2 gene in MPN was 62.5% (50/80). For non-MPN hematological diseases, four V617F mutations were detected in samples of leukocytosis of unknown origin (4/12), however, no JAK2 V617F mutations were identified in the 10 controls. Therefore, JAK2 V617F mutations may present a novel marker for diagnosis of MPNs. Furthermore, the direct sequencing method appeared to be satisfactory for the clinical gene testing of hematological samples. PMID:25624900

  1. Low complexity lossless compression of underwater sound recordings.

    PubMed

    Johnson, Mark; Partan, Jim; Hurst, Tom

    2013-03-01

    Autonomous listening devices are increasingly used to study vocal aquatic animals, and there is a constant need to record longer or with greater bandwidth, requiring efficient use of memory and battery power. Real-time compression of sound has the potential to extend recording durations and bandwidths at the expense of increased processing operations and therefore power consumption. Whereas lossy methods such as MP3 introduce undesirable artifacts, lossless compression algorithms (e.g., flac) guarantee exact data recovery. But these algorithms are relatively complex due to the wide variety of signals they are designed to compress. A simpler lossless algorithm is shown here to provide compression factors of three or more for underwater sound recordings over a range of noise environments. The compressor was evaluated using samples from drifting and animal-borne sound recorders with sampling rates of 16-240 kHz. It achieves >87% of the compression of more-complex methods but requires about 1/10 of the processing operations resulting in less than 1 mW power consumption at a sampling rate of 192 kHz on a low-power microprocessor. The potential to triple recording duration with a minor increase in power consumption and no loss in sound quality may be especially valuable for battery-limited tags and robotic vehicles.

  2. The role of microbial community composition and groundwater chemistry in determining isoproturon degradation potential in UK aquifers.

    PubMed

    Johnson, Andrew; Llewellyn, Neville; Smith, Jennifer; van der Gast, Christopher; Lilley, Andrew; Singer, Andrew; Thompson, Ian

    2004-07-01

    The community response of indigenous sandstone, chalk and limestone groundwater microorganisms to the addition of the commonly used herbicide isoproturon was examined. The addition of 100 microg l(-1) isoproturon generally caused an increase in species diversity determined by chemotaxonomic analysis (fatty methyl ester analysis) of isolates resulting from incubation of cultures at 18 degrees C for 4 days. Amongst the groundwater samples to which isoproturon was added, isoproturon degradation rates were correlated with increasing dominance of a few species. However, the changes in community profile associated with isoproturon degradation varied from site to site. Repeated sub-culturing with 100 microg l(-1) isoproturon and sterile groundwater was carried out to examine whether this level of pesticide could exert a selection pressure, and hence stimulate more rapid degradation. Significantly increased degradation was observed in a groundwater sample from the chalk, but not in sandstone, or limestone samples. The addition of filter-sterilised sandstone groundwater to bacteria on filter paper from slow degrading limestone sites significantly improved their degrading performance. The addition of filter-sterilised limestone groundwater to the sandstone bacteria reduced their degradation rate only slightly. The data suggested that the nature of the indigenous community does influence pesticide degradation in groundwater, but that the groundwater chemistry may also play a role.

  3. Effect of Stimulation Rate on Cochlear Implant Users’ Phoneme, Word and Sentence Recognition in Quiet and in Noise

    PubMed Central

    Shannon, Robert V.; Cruz, Rachel J.; Galvin, John J.

    2011-01-01

    High stimulation rates in cochlear implants (CI) offer better temporal sampling, can induce stochastic-like firing of auditory neurons and can increase the electric dynamic range, all of which could improve CI speech performance. While commercial CI have employed increasingly high stimulation rates, no clear or consistent advantage has been shown for high rates. In this study, speech recognition was acutely measured with experimental processors in 7 CI subjects (Clarion CII users). The stimulation rate varied between (approx.) 600 and 4800 pulses per second per electrode (ppse) and the number of active electrodes varied between 4 and 16. Vowel, consonant, consonant-nucleus-consonant word and IEEE sentence recognition was acutely measured in quiet and in steady noise (+10 dB signal-to-noise ratio). Subjective quality ratings were obtained for each of the experimental processors in quiet and in noise. Except for a small difference for vowel recognition in quiet, there were no significant differences in performance among the experimental stimulation rates for any of the speech measures. There was also a small but significant increase in subjective quality rating as stimulation rates increased from 1200 to 2400 ppse in noise. Consistent with previous studies, performance significantly improved as the number of electrodes was increased from 4 to 8, but no significant difference showed between 8, 12 and 16 electrodes. Altogether, there was little-to-no advantage of high stimulation rates in quiet or in noise, at least for the present speech tests and conditions. PMID:20639631

  4. Dielectric properties and carbothermic reduction of zinc oxide and zinc ferrite by microwave heating

    PubMed Central

    Fabritius, Timo; Heikkinen, Eetu-Pekka; Chen, Guo

    2017-01-01

    This paper aims to study the dielectric properties and carbothermic reduction of zinc oxide (zincite, ZnO) and zinc ferrite (franklinite, ZnFe2O4) by microwave heating. To achieve this aim, the dielectric properties were measured with an open-ended coaxial method to understand the behaviour of the samples under microwave irradiation. The effects of microwave power, duration time and sample mass on the heating rate, and the effects of the stoichiometric amount of graphite on the reduction of ZnO and decomposition of ZnFe2O4 were investigated. The results show that ZnFe2O4 has significantly higher dielectric properties compared to ZnO. Generally, for both samples, the dielectric values at room temperature were quite low, indicating that both ZnO and ZnFe2O4 are poor microwave absorbers. It was found that the temperatures have a more significant effect on the imaginary permittivities than on the real permittivities. The heating rate showed that the sample temperature increased with increase in microwave power and sample mass. Using 700 W of microwave power and two times the stoichiometric amount of graphite, almost complete reduction of ZnO was achieved in 12 min, while ZnFe2O4 completely decomposed to zincite and wustite in 3 min. PMID:28989772

  5. Implementation of a National Reference Laboratory for Buruli Ulcer Disease in Togo

    PubMed Central

    Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl–Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela

    2013-01-01

    Background In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Methodology Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions “Maritime” and “Central,” standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. Principal Findings The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. Conclusions High inter-laboratory concordance rates as well as case confirmation rates of 50% (microscopy), 71% (PCR at national level), and 78% (including qPCR confirmation at external reference laboratory) suggest high standards of BUD diagnostics. The increase of non-ulcerative lesions, as well as the decrease in diagnostic delay and category III lesions, prove the effect of comprehensive EQA and training measures involving also procedures outside the laboratory. PMID:23359828

  6. Implementation of a national reference laboratory for Buruli ulcer disease in Togo.

    PubMed

    Beissner, Marcus; Huber, Kristina Lydia; Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl-Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela

    2013-01-01

    In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions "Maritime" and "Central," standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. High inter-laboratory concordance rates as well as case confirmation rates of 50% (microscopy), 71% (PCR at national level), and 78% (including qPCR confirmation at external reference laboratory) suggest high standards of BUD diagnostics. The increase of non-ulcerative lesions, as well as the decrease in diagnostic delay and category III lesions, prove the effect of comprehensive EQA and training measures involving also procedures outside the laboratory.

  7. The Power of Low Back Pain Trials: A Systematic Review of Power, Sample Size, and Reporting of Sample Size Calculations Over Time, in Trials Published Between 1980 and 2012.

    PubMed

    Froud, Robert; Rajendran, Dévan; Patel, Shilpa; Bright, Philip; Bjørkli, Tom; Eldridge, Sandra; Buchbinder, Rachelle; Underwood, Martin

    2017-06-01

    A systematic review of nonspecific low back pain trials published between 1980 and 2012. To explore what proportion of trials have been powered to detect different bands of effect size; whether there is evidence that sample size in low back pain trials has been increasing; what proportion of trial reports include a sample size calculation; and whether likelihood of reporting sample size calculations has increased. Clinical trials should have a sample size sufficient to detect a minimally important difference for a given power and type I error rate. An underpowered trial is one within which probability of type II error is too high. Meta-analyses do not mitigate underpowered trials. Reviewers independently abstracted data on sample size at point of analysis, whether a sample size calculation was reported, and year of publication. Descriptive analyses were used to explore ability to detect effect sizes, and regression analyses to explore the relationship between sample size, or reporting sample size calculations, and time. We included 383 trials. One-third were powered to detect a standardized mean difference of less than 0.5, and 5% were powered to detect less than 0.3. The average sample size was 153 people, which increased only slightly (∼4 people/yr) from 1980 to 2000, and declined slightly (∼4.5 people/yr) from 2005 to 2011 (P < 0.00005). Sample size calculations were reported in 41% of trials. The odds of reporting a sample size calculation (compared to not reporting one) increased until 2005 and then declined (Equation is included in full-text article.). Sample sizes in back pain trials and the reporting of sample size calculations may need to be increased. It may be justifiable to power a trial to detect only large effects in the case of novel interventions. 3.

  8. Driven Boson Sampling.

    PubMed

    Barkhofen, Sonja; Bartley, Tim J; Sansoni, Linda; Kruse, Regina; Hamilton, Craig S; Jex, Igor; Silberhorn, Christine

    2017-01-13

    Sampling the distribution of bosons that have undergone a random unitary evolution is strongly believed to be a computationally hard problem. Key to outperforming classical simulations of this task is to increase both the number of input photons and the size of the network. We propose driven boson sampling, in which photons are input within the network itself, as a means to approach this goal. We show that the mean number of photons entering a boson sampling experiment can exceed one photon per input mode, while maintaining the required complexity, potentially leading to less stringent requirements on the input states for such experiments. When using heralded single-photon sources based on parametric down-conversion, this approach offers an ∼e-fold enhancement in the input state generation rate over scattershot boson sampling, reaching the scaling limit for such sources. This approach also offers a dramatic increase in the signal-to-noise ratio with respect to higher-order photon generation from such probabilistic sources, which removes the need for photon number resolution during the heralding process as the size of the system increases.

  9. Combined effects of cerium and cooling rate on microstructure and mechanical properties of AZ91 magnesium alloy

    NASA Astrophysics Data System (ADS)

    Cai, Huisheng; Guo, Feng; Su, Juan

    2018-01-01

    The specimens of AZ91-xCe(x = 0, 0.3, 0.6, 0.9, 1.2, mass fraction wt%) with different thicknesses were prepared by die casting process, their as-cast microstructure and room temperature mechanical properties were investigated to analyze the change rule of microstructure and mechanical properties of AZ91 magnesium alloy under combined effects of cooling rate and cerium content. The results show that, the microstructure and mechanical properties of AZ91 magnesium alloy were twofold influenced by cooling rate and cerium content. With the increase of cooling rate and Ce content, the average as-cast grain size is evidently refined; the amount of β-Mg17Al12 decreases and distribution becomes discrete. While decreasing cooling rate or increasing Ce content, Al4Ce phase is more and the morphology tends to strip and needle from granular and short rod-like. The tensile strength and elongation of AZ91-xCe magnesium alloy are improved with increasing cooling rate. With the increase of Ce content, the tensile strength and elongation of AZ91-xCe magnesium alloy increased first and decreased afterwards, besides the action of Ce to improve tensile strength and elongation is more evident under faster cooling rate. Mechanical properties of samples are optimal in this work, when Ce content is 0.96% and cooling rate is 39.6 K s-1, tensile strength (259.7 MPa) and elongation (5.5%) are reached maximum, respectively.

  10. Solid tissue culture for cytogenetic analysis: a collaborative survey for the Association of Clinical Cytogeneticists.

    PubMed Central

    Rodgers, C S; Creasy, M R; Fitchett, M; Maliszewska, C T; Pratt, N R; Waters, J J

    1996-01-01

    AIMS: To survey the diagnostic service provided by UK laboratories for the culture of solid tissue samples (excluding tumours) and in particular to examine the variation in culture success rates and the problems of maternal cell overgrowth. METHODS: Twenty seven laboratories took part in a collaborative survey during 1992. Each laboratory submitted data on up to a maximum of 60 consecutive specimens (n = 1361) over a six month period. RESULTS: Skin specimens, the largest category received (n = 520), were the most problematic (51% success rate). Culture success rates were significantly lower (43%) when skin specimens (n = 140) were transported dry to the laboratory. Success rates for skin specimens also varied, depending on the origin of the specimen, from 18% for intra-uterine deaths (IUD) (n = 94) to 85% for neonatal deaths (n = 33) and 83% for live patients (n = 54). Culture of selected extra-fetal tissues from IUD, stillbirths and following elective termination of pregnancy (TOP) gave comparable success rates to those achieved for skin samples from neonatal deaths and live births. Skewed sex ratios, female > male, were identified for products of conception (POC) (n = 298) and placental biopsy specimens (n = 97). CONCLUSIONS: By appropriate selection, transport and processing of tissues, and in particular by avoiding relying solely on skin samples from IUD, stillbirths and TOP, an increase in culture success rates for solid tissue samples submitted for cytogenetic analysis could be achieved. The high risk of maternal cell contamination from POC and placental biopsy specimens was also identified in this survey. PMID:8881913

  11. Prior leg massage decreases pain responses to heel stick in preterm babies.

    PubMed

    Jain, Sunil; Kumar, Praveen; McMillan, Douglas D

    2006-09-01

    Leg massage could inhibit the transmission of pain by 'closing the gate' or by activating the endogenous opioid pathway to decrease nociceptive transmission of pain associated with heel stick. The aim of this study is to determine the effects of massage therapy prior to heel stick on responses assessed by the Neonatal Infant Pain Scale (NIPS) (primary outcome), heart rate, respiratory rate and oxygen saturation (secondary outcomes) in infants who required a heel stick for blood sampling. This randomised, double-blind, crossover trial with infants from 1 to 7 days post birth excluded those with prior surgery, septicaemia, current assisted ventilation or an analgesic within 48 h. After informed consent, 13 infants received a 2-min massage of the ipsilateral leg prior to heel stick on the first study sampling and no massage on the next sampling 2-7 days later and 10 infants had the reverse order. The bedside nurse, blinded to the intervention, measured NIPS, heart rate, respiratory rate, and oxygen saturation prior to massage, after massage, and 5 min after heel stick. Serum cortisol was measured with the blood sampling. In 23 infants (birthweight 795-2507 g), there were no adverse physiologic effects of massage. After heel stick, NIPS (P < 0.001) and heart rate (P = 0.03) were increased in the no-massage group compared with the massage group. Respiratory rate, oxygen saturation and serum cortisol were not significantly different. Gentle massage of the leg prior to heel stick is safe and decreases pain responses in preterm infants.

  12. Nitrous oxide from aerated dairy manure slurries: Effects of aeration rates and oxic/anoxic phasing.

    PubMed

    Molodovskaya, Marina; Singurindy, Olga; Richards, Brian K; Steenhuis, Tammo S

    2008-12-01

    Small-scale laboratory research was conducted to compare the effects of different aeration rates and oxic/anoxic phasing on nitrous oxide (N(2)O) formation from dairy manure slurries. Manure slurry samples were incubated in triplicate for three-weeks under a range of continuous sweep gas flows (0.01-0.23L min(-1)kg(-1) slurry) with and without oxygen (air and dinitrogen gas). The net release of N(2)O-N was affected by both aeration rates and oxic/anoxic conditions, whereas ammonia volatilization depended mainly on gas flow rates. Maximum N(2)O-N losses after three-weeks incubation were 4.2% of total slurry N. Major N losses (up to 50% of total slurry N) were caused by ammonia volatilization that increased with increasing gas flow rates. The lowest nitrous oxide and ammonia production was observed from low flow phased oxic/anoxic treatment.

  13. Calibration and use of the polar organic chemical integrative sampler--a critical review.

    PubMed

    Harman, Christopher; Allan, Ian John; Vermeirssen, Etiënne L M

    2012-12-01

    The implementation of strict environmental quality standards for polar organic priority pollutants poses a challenge for monitoring programs. The polar organic chemical integrative sampler (POCIS) may help to address the challenge of measuring low and fluctuating trace concentrations of such organic contaminants, offering significant advantages over traditional sampling. In the present review, the authors evaluate POCIS calibration methods and factors affecting sampling rates together with reported environmental applications. Over 300 compounds have been shown to accumulate in POCIS, including pesticides, pharmaceuticals, hormones, and industrial chemicals. Polar organic chemical integrative sampler extracts have been used for both chemical and biological analyses. Several different calibration methods have been described, which makes it difficult to directly compare sampling rates. In addition, despite the fact that some attempts to correlate sampling rates with the properties of target compounds such as log K(OW) have been met with varying success, an overall model that can predict uptake is lacking. Furthermore, temperature, water flow rates, salinity, pH, and fouling have all been shown to affect uptake; however, there is currently no robust method available for adjusting for these differences. Overall, POCIS has been applied to a wide range of sampling environments and scenarios and has been proven to be a useful screening tool. However, based on the existing literature, a more mechanistic approach is required to increase understanding and thus improve the quantitative nature of the measurements. Copyright © 2012 SETAC.

  14. Rapid thermal annealing of WSi x. In-situ resistance measurements

    NASA Astrophysics Data System (ADS)

    Nobili, C.; Bosi, M.; Ottaviani, G.; Queirolo, G.; Bacci, L.

    1991-11-01

    In-situ sheet resistance measurements have been performed on amorphous WSi 2.5 alloy films deposited by low pressure chemical vapour deposition either on thermal oxide or on polysilicon. The heat treatments were performed in vacuum up to 1000°C at a heating rate ranging from 5 to 6000°C/min. The temperature was measured with a thermocouple placed underneath and in contact with the sample; the film sheet resistance was measured with a four-point probe in van der Pauw configuration. The in-depth elemental composition was determined by 2 MeV 4He + backscattering technique. Nuclear reaction was used to monitor the quantity of flourine present in the sample. The phases formed were identified by X-ray diffraction. The sheet resistance versus temperature curves are all similar and present, after a small initial decrease, first a sharp increase followed, after about 200°C, by a decrease. X-ray diffraction measurements indicate that the increase is due to the amorphous-hexagonal phase transformation; the decrease is due to the formation of the tetragonal WSi 2 phase. The temperature at which the two variations occur increases with the heating rate indicating thermally activated processes. The activation energies are 1.4 ±0.1 and 2.4 ±0.1 eV for the amorphous-hexagonal and hexagonal-tetragonal transformation, respectively. Silicon segregation at the inner interface occurs only on the samples where the silicide alloy was deposited on polysilicon and for heating rates lower than 200°C/min. The total flourine content is not affected by the kind of heat treatment performed.

  15. Culturally appropriate education intervention on biospecimen research participation among Chinese Americans.

    PubMed

    Gao, Wanzhen; Ma, Grace X; Tan, Yin; Fang, Carolyn; Weaver, Joellen; Jin, Ming; Lai, Philip; Godwin, Andrew K

    2014-03-01

    Chinese Americans are at increased risk for hepatitis B virus (HBV) infection. To reduce or eliminate disparities in HBV-related infection rates, participation in scientific investigations of HBV risk and treatment, including biospecimen sampling, is important. However, Asian Americans have low rates of participation in biospecimen research, and little is known about how educational interventions affect knowledge and participation in HBV-related biospecimen research. Eight Chinese community-based organizations participated in a quasi-experimental, two-group design with education assessments at pre- and postworkshop and a 3-month follow-up. Four sites were randomly assigned to receive the intervention (n = 175) and four sites to receive general health education (control; n = 240). Participant knowledge about biospecimen research increased from pre- to posteducation in the intervention but not in the control condition. Of intervention participants, 83.4% (146/175) donated one tube of blood for future HBV biospecimen research, and 50.9% (89/175) donated another tube of blood for HBV testing. In contrast, only 1.1% of participants in the control condition reported donating a blood sample at follow-up assessment. The intervention program significantly increased knowledge of and participation in HBV biospecimen research among Chinese Americans. Community-based participatory research (CBPR) methods featured active support by community leaders, a culturally specific curriculum, and convenient, immediate access to blood sampling, which resulted in high donation rates. HBV-related morbidity and mortality is an urgent problem faced by Chinese Americans. CBPR provides a model for engaging communities in early detection, vaccination, and treatment that can reduce this health threat. ©2014 AACR.

  16. Sniffing shapes the dynamics of olfactory bulb gamma oscillations in awake behaving rats.

    PubMed

    Rosero, Mario A; Aylwin, María L

    2011-09-01

    Mammals actively sample the environment for relevant olfactory objects. This active sampling is revealed by rapid changes in respiratory rate that influence the olfactory input. Yet the role of sniffing in shaping the neural responses to odorants has not been elucidated. In the olfactory bulb (OB), odorant-evoked gamma oscillations reflect the synchronous activity of mitral/tufted cells, a proposed mechanism for odorant representation. Here we examined the effect of sniffing frequency on the odorant-evoked gamma oscillations in the OB. We simultaneously recorded the respiratory rate and the local field potential while rats performed a lick/no-lick olfactory discrimination task with low odorant concentrations. High-frequency sniffing (HFS) augmented the power of gamma oscillations, suggesting an increase in the sensitivity to odorants. By contrast, coupling of the gamma oscillations to the sniff cycle and the amplitude of individual bursts were not modified by the respiratory rate. However, HFS prolonged the overall response to odorants and increased the frequency of the gamma oscillations, indicating that HFS reduces the adaptation to continuous odorant stimulation. Therefore, the increase in gamma power during HFS is the result of more frequent gamma bursts and the extended response to odorants. As odorant discrimination can be performed in a single sniff, a reduction in the adaptation mediated by HFS of novel odorants may facilitate odorant memory formation for subsequent odorant identification. Finally, these results corroborate that olfactory sampling should be integrated to the study of odorant coding in behaving animals. © 2011 The Authors. European Journal of Neuroscience © 2011 Federation of European Neuroscience Societies and Blackwell Publishing Ltd.

  17. Emission of volatile organic compounds from medical equipment inside neonatal incubators.

    PubMed

    Colareta Ugarte, U; Prazad, P; Puppala, B L; Schweig, L; Donovan, R; Cortes, D R; Gulati, A

    2014-08-01

    To determine emission of volatile organic compounds (VOCs) from plastic medical equipment within an incubator. Air samples from incubators before and after adding medical equipment were analyzed using EPA TO-15 methodology. Headspace analysis was used to identify VOC emissions from each medical equipment item. Air changes per hour (ACH) of each incubator were determined and used to calculate the emission rate of identified VOCs. Cyclohexanone was identified in all incubator air samples. At 28 °C, the mean concentration before and after adding medical equipment items was 2.1 ± 0.6 and 57.2 ± 14.9 μg m(-3),respectively (P<0.01). Concentrations increased to a mean of 83.8 ± 23.8 μg m(-)(3) (P<0.01) at 37(o)C and 93.0 ± 45.1 μg m(-)(3) (P=0.39) after adding 50% humidity. Intravenous tubing contributed 89% of cyclohexanone emissions. ACH were determined with access doors closed and open with means of 11.5 ± 1.7 and 44.1 ± 6.7 h(-1), respectively. Cyclohexanone emission rate increased from a mean of 102.2 μg h(-1) at 28(°C to 148.8 μg h(-1) (P<0.01) at 37 °C. Cyclohexanone was quantified in all incubator air samples containing plastic medical equipment. The concentration of cyclohexanone within the incubator was inversely related to ACH in the closed mode. The cyclohexanone concentration as well as the emission rate increased with higher temperature.

  18. Eye temperature and heart rate variability of calves disbudded with or without local anaesthetic.

    PubMed

    Stewart, M; Stafford, K J; Dowling, S K; Schaefer, A L; Webster, J R

    2008-03-18

    The possibility that pain can be detected from changes in eye temperature and heart rate variability (HRV) during disbudding was examined in thirty calves, randomly assigned to four treatments: 1) sham handling (control), 2) local anaesthetic (LA, cornual nerve injection) and sham disbudded, 3) sham LA and disbudded, 4) LA and disbudded. During a 40 min sampling period, maximum eye temperature, behavior and HRV parameters were recorded continuously. One week later, twelve disbudded calves were injected with adrenocorticotrophic hormone (ACTH) or saline and maximum eye temperature was recorded. There was a rapid drop in eye temperature during the 5 min following disbudding without LA (P<0.05). Eye temperature then increased and was higher than baseline over the remaining sampling period following both disbudding procedures (P<0.001), a response which could not be explained by increased physical activity LA increased eye temperature prior to disbudding (P<0.001). Heart rate increased (P<0.001) during the 5 min following disbudding with and without LA, however, LF/HF ratio only increased during this time (P<0.01) following disbudding without LA. Eye temperature did not change following ACTH, suggesting that hypothalamus-pituitary-adrenal axis (HPA) activity is not responsible for the changes in eye temperature following disbudding. The increase in LF/HF ratio following disbudding without LA suggests an acute sympathetic response to pain, which could be responsible for the drop in eye temperature via vasoconstriction. HRV and eye temperature together may be a useful non-invasive and more immediate index of pain than HPA activity alone.

  19. Microstructure and mechanical properties of eutectic B2O3-UO2 ceramic composites solidified at different cooling rates

    NASA Astrophysics Data System (ADS)

    Yusufu, Aikebaier; Uno, Masayoshi

    2018-02-01

    The removal of nuclear debris from damaged reactors by drilling or cutting requires an understanding of various properties of the solidified debris, such as mechanical properties (hardness, fractural features, strength, etc.) and microstructural properties like porosity, which have a significant impact on the mechanical properties. In this study, B2O3-UO2 composites were prepared by the eutectic reaction as solidified samples of mock fuel debris with a wide variety of porosities, and the porosity dependence of the mechanical properties under compression were characterized to obtain fundamental data on the complicated fuel debris. The porous eutectic B2O3-UO2 (B2O3/UO2 atomic ratio = 0.225:0.775) samples were successfully prepared by solidification of the molten phase below 2073 K, and the porosity increased as the pore network developed as the cooling rate was decreased. The nano- and microhardness as well as Young's moduli of the eutectic B2O3-UO2 samples were higher than those of UO2. However, the compressive strengths of the eutectic B2O3-UO2 samples were lower than that of UO2, and they decreased as the porosity increased. All samples showed typical brittle fracturing behavior. The low-porosity samples showed a linear elastic step up to a sudden rupture, whereas the high-porosity samples exhibited two main regimes: a linear elastic region that can be attributed to pore-edge bending or face stretching; a zigzag step that is related to the progression of pore collapse.

  20. Theory of Exciton Energy Transfer in Carbon Nanotube Composites

    DOE PAGES

    Davoody, A. H.; Karimi, F.; Arnold, M. S.; ...

    2016-06-24

    Here, we compute the exciton transfer (ET) rate between semiconducting single-wall carbon nanotubes (SWNTs). We show that the main reasons for the wide range of measured ET rates reported in the literature are (1) exciton confinement in local quantum wells stemming from disorder in the environment and (2) exciton thermalization between dark and bright states due to intratube scattering. The SWNT excitonic states are calculated by solving the Bethe–Salpeter equation using tight-binding basis functions. The ET rates due to intertube Coulomb interaction are computed via Fermi’s golden rule. In pristine samples, the ET rate between parallel (bundled) SWNTs of similarmore » chirality is very high (~10 14 s –1), while the ET rate for dissimilar or nonparallel tubes is considerably lower (~10 12 s –1). Exciton confinement reduces the ET rate between same-chirality parallel SWNTs by 2 orders of magnitude but has little effect otherwise. Consequently, the ET rate in most measurements will be on the order of 10 12 s –1, regardless of the tube relative orientation or chirality. Exciton thermalization between bright and dark states further reduces the ET rate to ~10 11 s –1. The ET rate also increases with increasing temperature and decreases with increasing dielectric constant of the surrounding medium.« less

  1. Theory of Exciton Energy Transfer in Carbon Nanotube Composites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davoody, A. H.; Karimi, F.; Arnold, M. S.

    Here, we compute the exciton transfer (ET) rate between semiconducting single-wall carbon nanotubes (SWNTs). We show that the main reasons for the wide range of measured ET rates reported in the literature are (1) exciton confinement in local quantum wells stemming from disorder in the environment and (2) exciton thermalization between dark and bright states due to intratube scattering. The SWNT excitonic states are calculated by solving the Bethe–Salpeter equation using tight-binding basis functions. The ET rates due to intertube Coulomb interaction are computed via Fermi’s golden rule. In pristine samples, the ET rate between parallel (bundled) SWNTs of similarmore » chirality is very high (~10 14 s –1), while the ET rate for dissimilar or nonparallel tubes is considerably lower (~10 12 s –1). Exciton confinement reduces the ET rate between same-chirality parallel SWNTs by 2 orders of magnitude but has little effect otherwise. Consequently, the ET rate in most measurements will be on the order of 10 12 s –1, regardless of the tube relative orientation or chirality. Exciton thermalization between bright and dark states further reduces the ET rate to ~10 11 s –1. The ET rate also increases with increasing temperature and decreases with increasing dielectric constant of the surrounding medium.« less

  2. The Effects of Tooth Brushing on Whole Salivary Flow Rate in Older Adults

    PubMed Central

    Trottier, K.; Garrick, R.; Mascarenhas, T.; Jang, Y.

    2018-01-01

    Objectives (1) To determine whether manual (MTB), or electric, tooth brushing (ETB) modulates whole salivary flow rate in older adults who are free of systemic disease. (2) To determine the duration of the brushing-related modulation of salivary flow rate. (3) To compare salivary flow rate modulation associated with MTB and ETB. Method Twenty-one adults aged 60 years and older participated in two experimental sessions during which they used a manual, or electric, toothbrush to brush their teeth, tongue, and palate. Whole salivary flow rates were determined using the draining method before, during, and after brushing. Differences in salivary flow rates across time periods, and between conditions, were examined using paired samples t-tests applying a Holm-Bonferroni sequential procedure (pcorr < 0.0045). The relationship between tooth brushing and age with respect to maximum salivary flow rate increase was examined using Pearson's correlation coefficient (p < 0.05). Results/Conclusion Whole salivary flow rates increased during, and for up to 5 minutes following, tooth brushing in adults aged 60 years and older who were free of systemic disease. The salivary effects of MTB and ETB were not significantly different. A moderate, positive correlation was observed between tooth-brushing-related maximum salivary flow rate increase and age. PMID:29682540

  3. Measuring thermal conductivity of polystyrene nanowires using the dual-cantilever technique.

    PubMed

    Canetta, Carlo; Guo, Samuel; Narayanaswamy, Arvind

    2014-10-01

    Thermal conductance measurements are performed on individual polystyrene nanowires using a novel measurement technique in which the wires are suspended between two bi-material microcantilever sensors. The nanowires are fabricated via electrospinning process. Thermal conductivity of the nanowire samples is found to be between 6.6 and 14.4 W m(-1) K(-1) depending on sample, a significant increase above typical bulk conductivity values for polystyrene. The high strain rates characteristic of electrospinning are believed to lead to alignment of molecular polymer chains, and hence the increase in thermal conductivity, along the axis of the nanowire.

  4. Effect of surface modification on hydration kinetics of carbamazepine anhydrate using isothermal microcalorimetry.

    PubMed

    Otsuka, Makoto; Ishii, Mika; Matsuda, Yoshihisa

    2003-01-01

    The purpose of this research was to improve the stability of carbamazepine (CBZ) bulk powder under high humidity by surface modification. The surface-modified anhydrates of CBZ were obtained in a specially designed surface modification apparatus at 60 degrees C via the adsorption of n-butanol, and powder x-ray diffraction, Fourier-Transformed Infrared spectra, and differential scanning calorimetry were used to determine the crystalline characteristics of the samples. The hydration process of intact and surface-modified CBZ anhydrate at 97% relative humidity (RH) and 40 +/-C 1 degrees C was automatically monitored by using isothermal microcalorimetry (IMC). The dissolution test for surface-modified samples (20 mg) was performed in 900 mL of distilled water at 37 +/-C 0.5 degrees C with stirring by a paddle at 100 rpm as in the Japanese Pharmacopoeia XIII. The heat flow profiles of hydration of intact and surface-modified CBZ anhydrates at 97% RH by using IMC profiles showed a maximum peak at around 10 hours and 45 hours after 0 and 10 hours of induction, respectively. The result indicated that hydration of CBZ anhydrate was completely inhibited at the initial stage by surface modification of n-butanol and thereafter transformed into dihydrate. The hydration of surface-modified samples followed a 2-dimensional phase boundary process with an induction period (IP). The IP of intact and surface-modified samples decreased with increase of the reaction temperature, and the hydration rate constant (k) increased with increase of the temperature. The crystal growth rate constants of nuclei of the intact sample were significantly larger than the surface-modified sample's at each temperature. The activation energy (E) of nuclei formation and crystal growth process for hydration of surface-modified CBZ anhydrate were evaluated to be 20.1 and 32.5 kJ/mol, respectively, from Arrhenius plots, but the Es of intact anhydrate were 56.3 and 26.8 kJ/mol, respectively. The dissolution profiles showed that the surface-modified sample dissolved faster than the intact sample at the initial stage. The dissolution kinetics were analyzed based on the Hixon-Crowell equation, and the dissolution rate constants for intact and surface-modified anhydrates were found to be 0.0102 +/-C 0.008 mg(1/3) x min(-1) and 0.1442 +/-C 0.0482 mg(1/3) x min(-1). The surface-modified anhydrate powders were more stable than the nonmodified samples under high humidity and showed resistance against moisture. However, surface modification induced rapid dissolution in water compared to the control.

  5. Influence of Al substitution on magnetism and adsorption properties of hematite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cao, Shanshan; Kang, Feifei; Yang, Xin

    2015-08-15

    A series of Al-substituted hematite was prepared. The structures and properties of as-prepared samples were characterized by various techniques. The magnetic property of the samples was determined and the adsorption of three dyes Acid Blue 74, Methylene Blue and Phenol Red onto the samples was investigated. The results showed that Al incorporation into the crystal structure of hematite occurs via isomorphous ionic substitution of Al for Fe. With increasing Al content, the particle size of samples decreases, the magnetization increases and the remanent magnetization remains unchanged. The coercivity of the samples increases with Al substitution up to n{sub Al}/n{sub Fe}more » 0.03, and then decreases as Al content further increases. Compared with Al-free hematite, Al-substituted samples exhibit better adsorption ability to all of the three dyes. The adsorption rates of the three dyes on the surface of Al substituted samples depend on the structure of dye, pH and Al content in hematite. - Graphical abstract: Effect of Al on the structure, magnetic properties and adsorption performance of hematite was investigated. - Highlights: • A series of Al-substituted α-Fe{sub 2}O{sub 3} was prepared. • Effect of Al content on the crystal structure and magnetic property of hematite was investigated. • Al-substituted hematite exhibits better adsorption ability than hematite.« less

  6. Type-II generalized family-wise error rate formulas with application to sample size determination.

    PubMed

    Delorme, Phillipe; de Micheaux, Pierre Lafaye; Liquet, Benoit; Riou, Jérémie

    2016-07-20

    Multiple endpoints are increasingly used in clinical trials. The significance of some of these clinical trials is established if at least r null hypotheses are rejected among m that are simultaneously tested. The usual approach in multiple hypothesis testing is to control the family-wise error rate, which is defined as the probability that at least one type-I error is made. More recently, the q-generalized family-wise error rate has been introduced to control the probability of making at least q false rejections. For procedures controlling this global type-I error rate, we define a type-II r-generalized family-wise error rate, which is directly related to the r-power defined as the probability of rejecting at least r false null hypotheses. We obtain very general power formulas that can be used to compute the sample size for single-step and step-wise procedures. These are implemented in our R package rPowerSampleSize available on the CRAN, making them directly available to end users. Complexities of the formulas are presented to gain insight into computation time issues. Comparison with Monte Carlo strategy is also presented. We compute sample sizes for two clinical trials involving multiple endpoints: one designed to investigate the effectiveness of a drug against acute heart failure and the other for the immunogenicity of a vaccine strategy against pneumococcus. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Age-related changes in the auditory brainstem response.

    PubMed

    Konrad-Martin, Dawn; Dille, Marilyn F; McMillan, Garnett; Griest, Susan; McDermott, Daniel; Fausti, Stephen A; Austin, Donald F

    2012-01-01

    This cross-sectional study had two goals: (1) Identify and quantify the effects of aging on the auditory brainstem response (ABR); (2) Describe how click rate and hearing impairment modify effects of aging. RESEARCH DESIGN AND ANALYSIS: ABR measures were obtained from 131 predominately male Veteran participants aged 26 to 71 yr. Metrics analyzed include amplitude and latency for waves I, III, and V, and the I-V interpeak latency interval (IPI) at three repetition rates (11, 51, and 71 clicks/sec) using both polarities. In order to avoid confounding from missing data due to hearing impairment, participants had hearing thresholds <40 dB HL at 2 kHz and 70 dB HL at 4 kHz in at least one ear. Additionally, the median 2, 3, and 4 kHz pure tone threshold average (PTA2,3,4) for the sample, ∼17 dB HL, was used to delineate subgroups of better and worse hearing ears, and only the better hearing sample was modeled statistically. We modeled ABR responses using age, repetition rate, and PTA2,3,4 as covariates. Random effects were used to model correlation between the two ears of a subject and across repetition rates. Inferences regarding effects of aging on ABR measures at each rate were derived from the fitted model. Results were compared to data from subjects with poorer hearing. Aging substantially diminished amplitudes of all of the principal ABR peaks, largely independent of any threshold differences within the group. For waves I and III, age-related amplitude decrements were greatest at a low (11/sec) click rate. At the 11/sec rate, the model-based mean wave III amplitude was significantly smaller in older compared with younger subjects even after adjusting for wave I amplitude. Aging also increased ABR peak latencies, with significant shifts limited to early waves. The I-V IPI did not change with age. For both younger and older subjects, increasing click presentation rate significantly decreased amplitudes of early peaks and prolonged latencies of later peaks, resulting in increased IPIs. Advanced age did not enhance effects of rate. Instead, the rate effect on wave I and III amplitudes was attenuated for the older subjects due to reduced peak amplitudes at lower click rates. Compared with model predictions from the sample of better hearing subjects, mean ABR amplitudes were diminished in the group with poorer hearing, and wave V latencies were prolonged. In a sample of veterans, aging substantially reduced amplitudes of all principal ABR peaks, with significant latency shifts limited to waves I and III. Aging did not influence the I-V IPI even at high click rates, suggesting that the observed absolute latency changes associated with aging can be attributed to changes in auditory nerve input. In contrast, ABR amplitude changes with age are not adequately explained by changes in wave I. Results suggest that aging reduces the numbers and/or synchrony of contributing auditory nerve units. Results also support the concept that aging reduces the numbers, though perhaps not the synchrony, of central ABR generators. American Academy of Audiology.

  8. Community-level physiological profiling performed with an oxygen-sensitive fluorophore in a microtiter plate

    NASA Technical Reports Server (NTRS)

    Garland, Jay L.; Roberts, Michael S.; Levine, Lanfang H.; Mills, Aaron L.

    2003-01-01

    Community-level physiological profiling based upon fluorometric detection of oxygen consumption was performed on hydroponic rhizosphere and salt marsh litter samples by using substrate levels as low as 50 ppm with incubation times between 5 and 24 h. The rate and extent of response were increased in samples acclimated to specific substrates and were reduced by limiting nitrogen availability in the wells.

  9. Integrative Cardiac Health Project, Windber Research Institute

    DTIC Science & Technology

    2014-07-01

    laparoscopically placed adjustable gastric banding (LAGB) baseline (5) and one year (5), control baseline (5) and one year (5). OD260/280 ratios...coverage and detection of 3-4 million CpG sites . All samples had a bisulfite conversion rate of >98.25%; number of CpG (methylated) sites per sample...methylation) and hyper-methylated (increasing methylation) sites in the three groups were identified. For LAGB patients, a heat map based on

  10. Prediction of indoor radon/thoron concentration in a model room from exhalation rates of building materials for different ventilation rates

    NASA Astrophysics Data System (ADS)

    Kumar, Manish; Sharma, Navjeet; Sarin, Amit

    2018-05-01

    Studies have confirmed that elevated levels of radon/thoron in the human-environments can substantially increase the risk of lung cancer in general population. The building materials are the second largest contributors to indoor radon/thoron after soil and bedrock beneath dwellings. In present investigation, the exhalation rates of radon/thoron from different building materials samples have been analysed using active technique. Radon/thoron concentrations in a model room have been predicted based on the exhalation rates from walls, floor and roof. The indoor concentrations show significant variations depending upon the ventilation rate and type of building materials used.

  11. The efficacy of protoporphyrin as a predictive biomarker for lead exposure in canvasback ducks: effect of sample storage time

    USGS Publications Warehouse

    Franson, J.C.; Hohman, W.L.; Moore, J.L.; Smith, M.R.

    1996-01-01

    We used 363 blood samples collected from wild canvasback dueks (Aythya valisineria) at Catahoula Lake, Louisiana, U.S.A. to evaluate the effect of sample storage time on the efficacy of erythrocytic protoporphyrin as an indicator of lead exposure. The protoporphyrin concentration of each sample was determined by hematofluorometry within 5 min of blood collection and after refrigeration at 4 °C for 24 and 48 h. All samples were analyzed for lead by atomic absorption spectrophotometry. Based on a blood lead concentration of ≥0.2 ppm wet weight as positive evidence for lead exposure, the protoporphyrin technique resulted in overall error rates of 29%, 20%, and 19% and false negative error rates of 47%, 29% and 25% when hematofluorometric determinations were made on blood at 5 min, 24 h, and 48 h, respectively. False positive error rates were less than 10% for all three measurement times. The accuracy of the 24-h erythrocytic protoporphyrin classification of blood samples as positive or negative for lead exposure was significantly greater than the 5-min classification, but no improvement in accuracy was gained when samples were tested at 48 h. The false negative errors were probably due, at least in part, to the lag time between lead exposure and the increase of blood protoporphyrin concentrations. False negatives resulted in an underestimation of the true number of canvasbacks exposed to lead, indicating that hematofluorometry provides a conservative estimate of lead exposure.

  12. Impact of New Quick Gold Nanoparticle-Based Cortisol Assay During Adrenal Vein Sampling for Primary Aldosteronism.

    PubMed

    Yoneda, Takashi; Karashima, Shigehiro; Kometani, Mitsuhiro; Usukura, Mikiya; Demura, Masashi; Sanada, Junichirou; Minami, Tetsuya; Koda, Wataru; Gabata, Toshifumi; Matsui, Osamu; Idegami, Koutarou; Takamura, Yuzuru; Tamiya, Eiichi; Oe, Masashi; Nakai, Masuo; Mori, Shunsuke; Terayama, Noboru; Matsuda, Yuichi; Kamemura, Kouhei; Fujii, Sumie; Seta, Takashi; Sawamura, Toshitaka; Okuda, Rika; Takeda, Yoshimichi; Hayashi, Kenshi; Yamagishi, Masakazu; Takeda, Yoshiyu

    2016-06-01

    Adrenal vein sampling (AVS) is essential for identifying a surgically curable form of primary aldosteronism (PA), but accurate placement of the sampling catheter is technically challenging. Intraprocedural cortisol measurement can confirm the catheter's position, thereby increasing the AVS success rate. We developed a quick cortisol assay (QCA) that uses immunochromatography and gold nanoparticles and can be performed either semiquantitatively or quantitatively. The assay was evaluated in two studies. In a single-center study, PA patients were assigned to undergo AVS incorporating the semiquantitative QCA (n = 30), the quantitative QCA (n = 30), or without the QCA (n = 30), and the rates of successful AVS were determined. In a prospective multicenter randomized, controlled study, the success rates of AVS performed with (n = 148) or without (n = 145) the semiquantitative QCA were determined. Cortisol concentrations were measured during AVS in 6 minutes or less in the radiology suite, without additional technical assistance, and significantly correlated with a conventional reference assay (R(2) = 0.994; P < .001). In the single-center study, the differences in the AVS success rates associated with semiquantitative and quantitative QCAs were not significant (both 93%); however, the success rates were significantly higher than the rate of successful AVS performed without using the QCA (63%; P < .001). The success rate of AVS performed in the multicenter study was 94% for the semiquantitative QCA, which was significantly higher than the rate for the patients without QCA (60%; P < .001). Our novel QCA was rapidly and easily performed at the point of care and improved the rate of successful AVS.

  13. A Nationwide Survey on the Prevalence of Intestinal Parasitic Infections in the Republic of Korea, 2004

    PubMed Central

    Kim, Tong-Soo; Cho, Shin-Hyeong; Huh, Sun; Kong, Yoon; Sohn, Woon-Mok; Hwang, Seung-Sik; Chai, Jong-Yil; Lee, Soon-Hyung; Park, Yun-Kyu; Oh, Dae-Kyu

    2009-01-01

    National surveys on the prevalence of intestinal parasitic infections have been carried out every 5-7 years since 1971 in the Republic of Korea in order to establish control measures. The present nationwide survey was conducted from June to December 2004. The 10% population sampling data of Population and Housing Census by the Korean government in 2000 was used as the survey population. One sample was selected randomly from each of the 22,858 registered subjects, and a total of 20,541 people were ultimately included in this survey. Fecal examinations were performed by the cellophane thick smear and saturated brine flotation techniques. Pinworm infection was examined by cello-tape anal swab method. This survey also included a questionnaire study for a socioeconomic analysis. The total helminth egg positive rate was 3.7%, and the estimated total positive number among nationwide people was 1,780,000. The rates in urban and rural areas were 3.1% and 6.8%, respectively. As the total egg positive rate in the 6th survey in 1997 was 2.4%, the present survey showed that there was a considerable degree of increase in the prevalence rate of intestinal parasitic infections over the 7-year period following the 6th survey. The largest increases occurred in the egg positive rates of Clonorchis sinensis and heterophyids including Metagonimus yokogawai. PMID:19290090

  14. The effect of elevated methane pressure on methane hydrate dissociation

    USGS Publications Warehouse

    Circone, S.; Stern, L.A.; Kirby, S.H.

    2004-01-01

    Methane hydrate, equilibrated at P, T conditions within the hydrate stability field, was rapidly depressurized to 1.0 or 2.0 MPa and maintained at isobaric conditions outside its stability field, while the extent and rate of hydrate dissociation was measured at fixed, externally maintained temperatures between 250 and 288 K. The dissociation rate decreases with increasing pressure at a given temperature. Dissociation rates at 1.0 MPa parallel the complex, reproducible T-dependence previously observed between 250 and 272 K at 0.1 MPa. The lowest rates were observed near 268 K, such that >50% of the sample can persist for more than two weeks at 0.1 MPa to more than a month at 1 and 2 MPa. Varying the pressure stepwise in a single experiment increased or decreased the dissociation rate in proportion to the rates observed in the isobaric experiments, similar to the rate reversibility previously observed with stepwise changes in temperature at 0.1 MPa. At fixed P, T conditions, the rate of methane hydrate dissociation decreases monotonically with time, never achieving a steady rate. The relationship between time (t) and the extent of hydrate dissociation is empirically described by: Evolved gas (%) = A??tB where the pre-exponential term A ranges from 0 to 16% s-B and the exponent B is generally <1. Based on fits of the dissociation results to Equation 1 for the full range of temperatures (204 to 289 K) and pressures (0.1 to 2.0 MPa) investigated, the derived parameters can be used to predict the methane evolution curves for pure, porous methane hydrate to within ??5%. The effects of sample porosity and the presence of quartz sand and seawater on methane hydrate dissociation are also described using Equation 1.

  15. Oxidation behaviour and electrical properties of cobalt/cerium oxide composite coatings for solid oxide fuel cell interconnects

    NASA Astrophysics Data System (ADS)

    Harthøj, Anders; Holt, Tobias; Møller, Per

    2015-05-01

    This work evaluates the performance of cobalt/cerium oxide (Co/CeO2) composite coatings and pure Co coatings to be used for solid oxide fuel cell (SOFC) interconnects. The coatings are electroplated on the ferritic stainless steels Crofer 22 APU and Crofer 22H. Coated and uncoated samples are exposed in air at 800 °C for 3000 h and oxidation rates are measured and oxide scale microstructures are investigated. Area-specific resistances (ASR) in air at 850 °C of coated and uncoated samples are also measured. A dual layered oxide scale formed on all coated samples. The outer layer consisted of Co, Mn, Fe and Cr oxide and the inner layer consisted of Cr oxide. The CeO2 was present as discrete particles in the outer oxide layer after exposure. The Cr oxide layer thicknesses and oxidations rates were significantly reduced for Co/CeO2 coated samples compared to for Co coated and uncoated samples. The ASR of all Crofer 22H samples increased significantly faster than of Crofer 22 APU samples which was likely due to the presence of SiO2 in the oxide/metal interface of Crofer 22H.

  16. Distortion correction of echo planar images applying the concept of finite rate of innovation to point spread function mapping (FRIP).

    PubMed

    Nunes, Rita G; Hajnal, Joseph V

    2018-06-01

    Point spread function (PSF) mapping enables estimating the displacement fields required for distortion correction of echo planar images. Recently, a highly accelerated approach was introduced for estimating displacements from the phase slope of under-sampled PSF mapping data. Sampling schemes with varying spacing were proposed requiring stepwise phase unwrapping. To avoid unwrapping errors, an alternative approach applying the concept of finite rate of innovation to PSF mapping (FRIP) is introduced, using a pattern search strategy to locate the PSF peak, and the two methods are compared. Fully sampled PSF data was acquired in six subjects at 3.0 T, and distortion maps were estimated after retrospective under-sampling. The two methods were compared for both previously published and newly optimized sampling patterns. Prospectively under-sampled data were also acquired. Shift maps were estimated and deviations relative to the fully sampled reference map were calculated. The best performance was achieved when using FRIP with a previously proposed sampling scheme. The two methods were comparable for the remaining schemes. The displacement field errors tended to be lower as the number of samples or their spacing increased. A robust method for estimating the position of the PSF peak has been introduced.

  17. Rising rates, changing relationships: caesarean section and its correlates in South Korea, 1988-2000.

    PubMed

    Lee, Sang-Il; Khang, Young-Ho; Yun, Sungcheol; Jo, Min-Woo

    2005-06-01

    To examine the trends in the relationship between caesarean section rates in South Korea and its correlates. Five rounds (1988, 1991, 1994, 1997 and 2000) of population-based National Fertility and Family Health Survey of South Korea. South Korea. Sample Mothers (N= 9184) aged 15-44 years. Caesarean rates were calculated according to correlates and then directly adjusted to five-year age and parity groups. Distribution of all samples (9184 mothers) was standard, producing age- and parity-adjusted caesarean rates. Linear trends of correlates with caesarean rates were examined for ordinal variables such as education, income, urbanisation level (area of residence) and level of prenatal visits. Age- and parity-adjusted caesarean section rates. As caesarean rates rose by year, the relationship of caesarean section with education, occupation and area of residence has been reversed. Associations between caesarean rates, income level, place of delivery and level of prenatal visit were found in 1988 but disappeared by 2000. In 2000, relatively low caesarean rates were found in variables that will be more prevalent in the future, such as higher maternal education, higher maternal occupation and residence in big cities. Caesarean rates may have reached a plateau in South Korea. No maternal or health service factors were detected to further increase the proportion of caesarean deliveries.

  18. A multi-purpose readout electronics for CdTe and CZT detectors for x-ray imaging applications

    NASA Astrophysics Data System (ADS)

    Yue, X. B.; Deng, Z.; Xing, Y. X.; Liu, Y. N.

    2017-09-01

    A multi-purpose readout electronics based on the DPLMS digital filter has been developed for CdTe and CZT detectors for X-ray imaging applications. Different filter coefficients can be synthesized optimized either for high energy resolution at relatively low counting rate or for high rate photon-counting with reduced energy resolution. The effects of signal width constraints, sampling rate and length were numerical studied by Mento Carlo simulation with simple CRRC shaper input signals. The signal width constraint had minor effect and the ENC was only increased by 6.5% when the signal width was shortened down to 2 τc. The sampling rate and length depended on the characteristic time constants of both input and output signals. For simple CR-RC input signals, the minimum number of the filter coefficients was 12 with 10% increase in ENC when the output time constant was close to the input shaping time. A prototype readout electronics was developed for demonstration, using a previously designed analog front ASIC and a commercial ADC card. Two different DPLMS filters were successfully synthesized and applied for high resolution and high counting rate applications respectively. The readout electronics was also tested with a linear array CdTe detector. The energy resolutions of Am-241 59.5 keV peak were measured to be 6.41% in FWHM for the high resolution filter and to be 13.58% in FWHM for the high counting rate filter with 160 ns signal width constraint.

  19. Smoking rates and risk factors among youth in the Republic of the Marshall Islands: results of a school survey.

    PubMed

    Chen, Tai-Ho; Ou, Alan C; Haberle, Heather; Miller, Vincent P; Langidrik, Justina R; Palafox, Neal A

    2004-09-01

    Rapidly increasing tobacco use in developing countries will result in a large and increasing burden of tobacco-related illnesses as their populations age. The Republic of the Marshall Islands (RMI) is an island nation in the Pacific with a 1999 census population of 50,840, of whom more than fifty percent were under twenty years of age. There are limited data on the prevalence of smoking among youth in the RMI. A school survey of 3,294 RMI students in grades 5 through 12 was conducted in 2000. Urban and outer atoll schools were included in the sample. Demographic data and information on tobacco use and risk factors were collected. The overall smoking rate in this school sample was 10.6%. There were significantly higher smoking rates in the high school age group; the rate of smoking among 18 year olds was 33.5%. Smoking rates were higher among males compared to females (18.7% vs. 3.4%) and higher among outer atoll students compared to urban students (14.5% vs. 9.4%). The most prominent risk factors for smoking were: age, male gender, receiving or wearing tobacco-labeled equipment or clothing and willingness to participate in other high-risk behaviors. The survey provides an estimate of smoking rates among Marshallese school students and identifies and quantifies significant risk factors for smoking. This information can assist in guiding a comprehensive tobacco control strategy in the Republic of the Marshall Islands.

  20. Tuning the Mechanical and Antimicrobial Performance of a Cu-Based Metallic Glass Composite through Cooling Rate Control and Annealing.

    PubMed

    Villapún, Victor M; Esat, F; Bull, S; Dover, L G; González, S

    2017-05-06

    The influence of cooling rate on the wear and antimicrobial performance of a Cu 52 Z 41 Al₇ (at. %) bulk metallic glass (BMG) composite was studied and the results compared to those of the annealed sample (850 °C for 48 h) and to pure copper. The aim of this basic research is to explore the potential use of the material in preventing the spread of infections. The cooling rate is controlled by changing the mould diameter (2 mm and 3 mm) upon suction casting and controlling the mould temperature (chiller on and off). For the highest cooling rate conditions CuZr is formed but CuZr₂ starts to crystallise as the cooling rate decreases, resulting in an increase in the wear resistance and brittleness, as measured by scratch tests. A decrease in the cooling rate also increases the antimicrobial performance, as shown by different methodologies (European, American and Japanese standards). Annealing leads to the formation of new intermetallic phases (Cu 10 Zr₇ and Cu₂ZrAl) resulting in maximum scratch hardness and antimicrobial performance. However, the annealed sample corrodes during the antimicrobial tests (within 1 h of contact with broth). The antibacterial activity of copper was proved to be higher than that of any of the other materials tested but it exhibits very poor wear properties. Cu-rich BMG composites with optimised microstructure would be preferable for some applications where the durability requirements are higher than the antimicrobial needs.

Top