Sample records for independence evaluation system

  1. Integrated Vehicle-Based Safety Systems (IVBSS) Light Vehicle Field Operational Test Independent Evaluation

    DOT National Transportation Integrated Search

    2011-10-01

    This report presents the methodology and results of the independent evaluation of a prototype integrated crash warning system for : light vehicles as part of the Integrated Vehicle-Based Safety Systems initiative of the United States Department of : ...

  2. Independent Evaluation of the Driver Acceptance of the Cooperative Intersection Collision Avoidance System for Violations (CICAS-V) Pilot Test

    DOT National Transportation Integrated Search

    2011-07-01

    This report documents the results of the independent evaluations assessment of the driver acceptance of the Cooperative Intersection Collision Avoidance System limited to Stop Sign and Traffic Signal Violations (CICAS-V) system as tested during a ...

  3. Integrated vehicle-based safety systems : heavy-truck field operational test independent evaluation.

    DOT National Transportation Integrated Search

    2011-05-01

    This report presents results from the independent evaluation of a field operational test using a fleet of heavy trucks outfitted with a prototype integrated crash warning system. This effort was conducted as part of the U.S. DOT?s Integrated Vehicle-...

  4. [Independent ethics committees for clinical research in Argentina. An evaluation and a system to guarantee their independence].

    PubMed

    Gonorazky, Sergio E

    2008-01-01

    The Administración Nacional de Medicamentos, Alimentos y Tecnología Médica de la República Argentina (ANMAT) requires that an independent ethics committee of sponsors and/or researchers must previously evaluate and approve all the new pharmacological research protocols carried out on human beings. However, due to the lucrative nature of the evaluation, and because the selection of the Independent Ethics Committee is carried out by the sponsors and/or researchers, the assumed autonomy of the former can be reduced to merely a relationship of "service provider-customer". The Institutional Review Board of the Mar del Plata s Community Hospital has evaluated, between 2005 and 2006, thirty three research protocols (with their corresponding information sheets for patients and informed consent forms) previously approved by a non-institutional Independent Ethics Committee. The median number of objections made by the Institutional Review Board, which prompted the previously mentioned protocols to be modified in order to be approved, was of three per protocol. In other words, the accreditation of an Independent Ethics Committee requires a system that guarantees actual independence from the sponsors and/or researchers, as well as management control mechanisms that may lead them into an eventual loss of accreditation. Several measures are proposed in order to correct the deficiencies of the present system.

  5. GATEWAY Report Brief: Tuning the Light in Classrooms: Evaluating Trial LED Lighting Systems in Three Classrooms at the Carrollton-Farmers Branch Independent School District in Carrollton, TX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Summary of GATEWAY report evaluating a trial installation of tunable-white LED lighting systems in three classrooms in the Carrollton-Farmers Branch Independent School District in Carrollton, TX. The report provides valuable insights into the use of this technology in a real-world setting.

  6. GATEWAY Report: Tuning the Light in Classrooms: Evaluating Trial LED Lighting Systems in Three Classrooms at the Carrollton-Farmers Branch Independent School District in Carrollton, TX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Robert G.; Wilkerson, Andrea

    The GATEWAY program evaluated a trial installation of tunable-white LED lighting systems in three classrooms in the Carrollton-Farmers Branch Independent School District in Carrollton, TX. The report provides valuable insights into the use of this technology in a real-world setting.

  7. Freight information real-time system for transport : evaluation final report

    DOT National Transportation Integrated Search

    2003-10-01

    This report presents the findings of an independent evaluation of the Freight Information Real-time System for Transport (FIRST) intermodal freight Intelligent Transportation System (ITS) prototype system. FIRST is an Internet-based, real-time networ...

  8. Appliance of Independent Component Analysis to System Intrusion Analysis

    NASA Astrophysics Data System (ADS)

    Ishii, Yoshikazu; Takagi, Tarou; Nakai, Kouji

    In order to analyze the output of the intrusion detection system and the firewall, we evaluated the applicability of ICA(independent component analysis). We developed a simulator for evaluation of intrusion analysis method. The simulator consists of the network model of an information system, the service model and the vulnerability model of each server, and the action model performed on client and intruder. We applied the ICA for analyzing the audit trail of simulated information system. We report the evaluation result of the ICA on intrusion analysis. In the simulated case, ICA separated two attacks correctly, and related an attack and the abnormalities of the normal application produced under the influence of the attach.

  9. ORE's GENeric Evaluation SYStem: GENESYS 1988-89.

    ERIC Educational Resources Information Center

    Baenen, Nancy; And Others

    GENESYS--GENeric Evaluation SYStem--is a method of streamlining data collection and evaluation through the use of computer technology. GENESYS has allowed the Office of Research and Evaluation (ORE) of the Austin (Texas) Independent School District to evaluate a multitude of contrasting programs with limited resources. By standardizing methods and…

  10. Evaluation of the "e-rater"® Scoring Engine for the "TOEFL"® Independent and Integrated Prompts. Research Report. ETS RR-12-06

    ERIC Educational Resources Information Center

    Ramineni, Chaitanya; Trapani, Catherine S.; Williamson, David M.; Davey, Tim; Bridgeman, Brent

    2012-01-01

    Scoring models for the "e-rater"® system were built and evaluated for the "TOEFL"® exam's independent and integrated writing prompts. Prompt-specific and generic scoring models were built, and evaluation statistics, such as weighted kappas, Pearson correlations, standardized differences in mean scores, and correlations with…

  11. Testing of Mortar Systems

    DTIC Science & Technology

    2010-03-11

    IEP /TDP) or Independent Assessment Plan (IAP), and the test item and the procedures as outlined in this TOP. The following must also be considered...Command DTIC = Defense Technical Information Center DTP = Detailed Test Plan IAP = Independent Assessment Plan IEP = Independent Evaluation Plan IPT

  12. Independent Evaluation of Heavy-Truck Safety Applications Based on Vehicle-to-Vehicle and Vehicle-to-Infrastructure Communications Used in the Safety Pilot Model Deployment

    DOT National Transportation Integrated Search

    2016-01-01

    This report presents the methodology and results of the independent evaluation of heavy trucks (HTs) in the Safety Pilot Model Deployment (SPMD); part of the United States Department of Transportations Intelligent Transportation Systems research p...

  13. Theory of Aircraft Collision-Avoidance System Design and Evaluation

    DOT National Transportation Integrated Search

    1971-05-01

    The problem of aircraft anti-collision system design and evaluation is discussed in this work. Two evaluation criteria, conflict ratio and probability of missed critical alarm are formulated and are found to be independent of both traffic density and...

  14. An evaluation method of computer usability based on human-to-computer information transmission model.

    PubMed

    Ogawa, K

    1992-01-01

    This paper proposes a new evaluation and prediction method for computer usability. This method is based on our two previously proposed information transmission measures created from a human-to-computer information transmission model. The model has three information transmission levels: the device, software, and task content levels. Two measures, called the device independent information measure (DI) and the computer independent information measure (CI), defined on the software and task content levels respectively, are given as the amount of information transmitted. Two information transmission rates are defined as DI/T and CI/T, where T is the task completion time: the device independent information transmission rate (RDI), and the computer independent information transmission rate (RCI). The method utilizes the RDI and RCI rates to evaluate relatively the usability of software and device operations on different computer systems. Experiments using three different systems, in this case a graphical information input task, confirm that the method offers an efficient way of determining computer usability.

  15. Evaluating gaze-driven power wheelchair with navigation support for persons with disabilities.

    PubMed

    Wästlund, Erik; Sponseller, Kay; Pettersson, Ola; Bared, Anders

    2015-01-01

    This article describes a novel add-on for powered wheelchairs that is composed of a gaze-driven control system and a navigation support system. The add-on was tested by three users. All of the users were individuals with severe disabilities and no possibility of moving independently. The system is an add-on to a standard power wheelchair and can be customized for different levels of support according to the cognitive level, motor control, perceptual skills, and specific needs of the user. The primary aim of this study was to test the functionality and safety of the system in the user's home environment. The secondary aim was to evaluate whether access to a gaze-driven powered wheelchair with navigation support is perceived as meaningful in terms of independence and participation. The results show that the system has the potential to provide safe, independent indoor mobility and that the users perceive doing so as fun, meaningful, and a way to reduce dependency on others. Independent mobility has numerous benefits in addition to psychological and emotional well-being. By observing users' actions, caregivers and healthcare professionals can assess the individual's capabilities, which was not previously possible. Rehabilitation can be better adapted to the individual's specific needs, and driving a wheelchair independently can be a valuable, motivating training tool.

  16. Evaluation of an automotive rear-end collision avoidance system

    DOT National Transportation Integrated Search

    2006-04-01

    This report presents the results of an independent evaluation of the Automotive Collision Avoidance System (ACAS). The ACAS integrates forward collision warning (FCW) and adaptive cruise control (ACC) functions for light-vehicle applications. The FCW...

  17. Effects of Implementing the Picture Exchange Communication System (PECS) with Adults with Developmental Disabilities and Severe Communication Deficits

    ERIC Educational Resources Information Center

    Conklin, Carl G.; Mayer, G. Roy

    2011-01-01

    The purpose of this study is to evaluate the effects of "Picture Exchange Communication System" (PECS) training, using a multiple baseline design on the independent initiations of three adults with developmental disabilities and severe communication deficits. All participants increased their independent initiations, although at different…

  18. Design, implementation and evaluation of an independent real-time safety layer for medical robotic systems using a force-torque-acceleration (FTA) sensor.

    PubMed

    Richter, Lars; Bruder, Ralf

    2013-05-01

    Most medical robotic systems require direct interaction or contact with the robot. Force-Torque (FT) sensors can easily be mounted to the robot to control the contact pressure. However, evaluation is often done in software, which leads to latencies. To overcome that, we developed an independent safety system, named FTA sensor, which is based on an FT sensor and an accelerometer. An embedded system (ES) runs a real-time monitoring system for continuously checking of the readings. In case of a collision or error, it instantaneously stops the robot via the robot's external emergency stop. We found that the ES implementing the FTA sensor has a maximum latency of [Formula: see text] ms to trigger the robot's emergency stop. For the standard settings in the application of robotized transcranial magnetic stimulation, the robot will stop after at most 4 mm. Therefore, it works as an independent safety layer preventing patient and/or operator from serious harm.

  19. Situation-Dependent Medical Device Risk Estimation: Design and Evaluation of an Equipment Management Center For Vendor-Independent Integrated Operating Rooms.

    PubMed

    Maktabi, Marianne; Neumuth, Thomas

    2017-12-22

    The complexity of surgical interventions and the number of technologies involved are constantly rising. Hospital staff has to learn how to handle new medical devices efficiently. However, if medical device-related incidents occur, the patient treatment is delayed. Patient safety could therefore be supported by an optimized assistance system that helps improve the management of technical equipment by nonmedical hospital staff. We developed a system for the optimal monitoring of networked medical device activity and maintenance requirements, which works in conjunction with a vendor-independent integrated operating room and an accurate surgical intervention Time And Resource Management System. An integrated situation-dependent risk assessment system gives the medical engineers optimal awareness of the medical devices in the operating room. A qualitative and quantitative survey among ten medical engineers from three different hospitals was performed to evaluate the approach. A series of 25 questions was used to evaluate various aspects of our system as well as the system currently used. Moreover, the respondents were asked to perform five tasks related to system supervision and incident handling. Our system received a very positive feedback. The evaluation studies showed that the integration of information, the structured presentation of information, and the assistance modules provide valuable support to medical engineers. An automated operating room monitoring system with an integrated risk assessment and Time And Resource Management System module is a new way to assist the staff being outside of a vendor-independent integrated operating room, who are nevertheless involved in processes in the operating room.

  20. Federal Motor Carrier Safety Administration’s Advanced System Testing Utilizing a Data Acquisition System on the Highways (FAST DASH) Safety Technology Evaluation Project #2: Driver Monitoring Final Report.

    DOT National Transportation Integrated Search

    2016-12-01

    An independent evaluation of a non-video-based onboard monitoring system (OBMS) was conducted. The objective was to determine if the OBMS system performed reliably, improved driving safety and performance, and improved fuel efficiency in a commercial...

  1. Federal Motor Carrier Safety Administration’s advanced system testing utilizing a data acquisition system on the highways (FAST DASH) safety technology evaluation project #2 : driver monitoring, final report.

    DOT National Transportation Integrated Search

    2016-11-01

    An independent evaluation of a non-video-based onboard monitoring system (OBMS) was conducted. The objective was to determine if the OBMS system performed reliably, improved driving safety and performance, and improved fuel efficiency in a commercial...

  2. Platform for frail elderly people supporting information and communication.

    PubMed

    Man, Yan Ping; Cremers, Ger; Spreeuwenberg, Marieke; de Witte, Luc

    2015-01-01

    There is a growing need for technology to support the frail elderly living independently in home situations. Several telecommunication systems already exist. These systems are developed mainly from the perspective of healthcare professionals and focus on efficient delivery of healthcare services. They hardly meet the specific needs of the frail elderly. In this project a platform with specific needs of the frail elderly people has been designed, running on standard PCs. This system supports living independently, social participation, wellbeing, and asking for care services. The platform was evaluated and subjects assess the system as user friendly, and supportive for their independence and self-reliance. They recommend it to other users.

  3. Evaluating the Safety Benefits of a Low-Cost Driving Behavior Management System in Commercial Vehicle Operations

    DOT National Transportation Integrated Search

    2010-04-01

    This project provides an independent evaluation of a commercially available low-cost driving behavior management system. Participating drivers from two carriers (identified as Carrier A and Carrier B) drove an instrumented vehicle for 17 consecutive ...

  4. On Information Retrieval (IR) Systems: Revisiting Their Development, Evaluation Methodologies, and Assumptions (SIGs LAN, ED).

    ERIC Educational Resources Information Center

    Stirling, Keith

    2000-01-01

    Describes a session on information retrieval systems that planned to discuss relevance measures with Web-based information retrieval; retrieval system performance and evaluation; probabilistic independence of index terms; vector-based models; metalanguages and digital objects; how users assess the reliability, timeliness and bias of information;…

  5. Evaluation of the PuSHMe regional mayday system operational test : final report

    DOT National Transportation Integrated Search

    1997-09-01

    This report is an independent evaluation of the Puget Sound Emergency Response Operational Test (PuSHMe), a test of regional mayday systems that allow a driver to signal his or her location and need for assistance to a response center.

  6. Evaluation of a Road-Departure Crash Warning System.

    DOT National Transportation Integrated Search

    2007-12-31

    This report presents the results of an independent evaluation of the Road-Departure Crash Warning System (RDCW), which is designed to warn drivers when they are drifting out of their lane or about to enter a curve at an unsafe speed. The RDCW lateral...

  7. Xilinx Virtex-5QV (V5QV) Independent SEU Data

    NASA Technical Reports Server (NTRS)

    Berg, Melanie D.; LaBel, Kenneth A.; Pellish, Jonathan

    2014-01-01

    This is an independent study to determine the single event destructive and transient susceptibility of the Xilinx Virtex-5QV (SIRF) device. A framework for evaluating complex digital systems targeted for harsh radiation environments such as space is presented.

  8. FMCSA’s advanced system testing utilizing a data acquisition system on the highways (FAST DASH) safety technology evaluation project #2 : technology brief.

    DOT National Transportation Integrated Search

    2016-11-01

    The Federal Motor Carrier Safety Administration (FMCSA) established the FAST DASH program to perform efficient independent evaluations of promising safety technologies aimed at commercial vehicle operations. In this second FAST DASH safety technology...

  9. Nuclear fuel management optimization using genetic algorithms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeChaine, M.D.; Feltus, M.A.

    1995-07-01

    The code independent genetic algorithm reactor optimization (CIGARO) system has been developed to optimize nuclear reactor loading patterns. It uses genetic algorithms (GAs) and a code-independent interface, so any reactor physics code (e.g., CASMO-3/SIMULATE-3) can be used to evaluate the loading patterns. The system is compared to other GA-based loading pattern optimizers. Tests were carried out to maximize the beginning of cycle k{sub eff} for a pressurized water reactor core loading with a penalty function to limit power peaking. The CIGARO system performed well, increasing the k{sub eff} after lowering the peak power. Tests of a prototype parallel evaluation methodmore » showed the potential for a significant speedup.« less

  10. Houston, We Have a Problem: Studying the SAS Education Value-Added Assessment System (EVAAS) from Teachers' Perspectives in the Houston Independent School District (HISD)

    ERIC Educational Resources Information Center

    Collins, Clarin

    2012-01-01

    This study examined the intended and unintended consequences associated with the Education Value-Added Assessment System (EVAAS) as perceived and experienced by teachers in the Houston Independent School District (HISD). To evaluate teacher effectiveness, HISD is using EVAAS for high-stakes consequences more than any other district or state in the…

  11. Real-time Identification System using Mobile Hand-held Devices: Mobile Biometrics Evaluation Framework

    DTIC Science & Technology

    2014-04-01

    must be done to determine current infrastructure and capabilities so that necessary updates and changes can be addressed up front. Mobile biometric...with existing satellite communications infrastructure . 20 PSTP 03-427BIOM 4 State of Mobile Biometric Device Market 4.1 Fingerprint...is a wireless information system highlighted by Real-time wireless data collection mobile device independence, wireless infrastructure independence

  12. The Use of Video Modeling with the Picture Exchange Communication System to Increase Independent Communicative Initiations in Preschoolers with Autism and Developmental Delays

    ERIC Educational Resources Information Center

    Cihak, David F.; Smith, Catherine C.; Cornett, Ashlee; Coleman, Mari Beth

    2012-01-01

    The use of video modeling (VM) procedures in conjunction with the picture exchange communication system (PECS) to increase independent communicative initiations in preschool-age students was evaluated in this study. The four participants were 3-year-old children with limited communication skills prior to the intervention. Two of the students had…

  13. FMCSA’s advanced system testing utilizing a data acquisition system on the highways (FAST DASH) safety technology evaluation project #3 : novel convex mirrors : technology brief.

    DOT National Transportation Integrated Search

    2016-11-01

    The Federal Motor Carrier Safety Administration (FMCSA) established the FAST DASH program to perform efficient independent evaluations of promising safety technologies aimed at commercial vehicle operations. In this third FAST DASH safety technology ...

  14. Parsimonious Use of Indicators for Evaluating Sustainability Systems with Multivariate Statistical Analyses

    EPA Science Inventory

    Indicators are commonly used for evaluating relative sustainability for competing products and processes. When a set of indicators is chosen for a particular system of study, it is important to ensure that they are variable independently of each other. Often the number of indicat...

  15. User Interface Problems of a Nationwide Inpatient Information System: A Heuristic Evaluation.

    PubMed

    Atashi, Alireza; Khajouei, Reza; Azizi, Amirabbas; Dadashi, Ali

    2016-01-01

    While studies have shown that usability evaluation could uncover many design problems of health information systems, the usability of health information systems in developing countries using their native language is poorly studied. The objective of this study was to evaluate the usability of a nationwide inpatient information system used in many academic hospitals in Iran. Three trained usability evaluators independently evaluated the system using Nielsen's 10 usability heuristics. The evaluators combined identified problems in a single list and independently rated the severity of the problems. We statistically compared the number and severity of problems identified by HIS experienced and non-experienced evaluators. A total of 158 usability problems were identified. After removing duplications 99 unique problems were left. The highest mismatch with usability principles was related to "Consistency and standards" heuristic (25%) and the lowest related to "Flexibility and efficiency of use" (4%). The average severity of problems ranged from 2.4 (Major problem) to 3.3 (Catastrophe problem). The experienced evaluator with HIS identified significantly more problems and gave higher severities to problems (p<0.02). Heuristic Evaluation identified a high number of usability problems in a widely used inpatient information system in many academic hospitals. These problems, if remain unsolved, may waste users' and patients' time, increase errors and finally threaten patient's safety. Many of them can be fixed with simple redesign solutions such as using clear labels and better layouts. This study suggests conducting further studies to confirm the findings concerning effect of evaluator experience on the results of Heuristic Evaluation.

  16. User Interface Problems of a Nationwide Inpatient Information System: A Heuristic Evaluation

    PubMed Central

    Atashi, Alireza; Azizi, Amirabbas; Dadashi, Ali

    2016-01-01

    Summary Introduction While studies have shown that usability evaluation could uncover many design problems of health information systems, the usability of health information systems in developing countries using their native language is poorly studied. The objective of this study was to evaluate the usability of a nationwide inpatient information system used in many academic hospitals in Iran. Material and Methods Three trained usability evaluators independently evaluated the system using Nielsen’s 10 usability heuristics. The evaluators combined identified problems in a single list and independently rated the severity of the problems. We statistically compared the number and severity of problems identified by HIS experienced and non-experienced evaluators. Results A total of 158 usability problems were identified. After removing duplications 99 unique problems were left. The highest mismatch with usability principles was related to “Consistency and standards” heuristic (25%) and the lowest related to “Flexibility and efficiency of use” (4%). The average severity of problems ranged from 2.4 (Major problem) to 3.3 (Catastrophe problem). The experienced evaluator with HIS identified significantly more problems and gave higher severities to problems (p<0.02). Discussion Heuristic Evaluation identified a high number of usability problems in a widely used inpatient information system in many academic hospitals. These problems, if remain unsolved, may waste users’ and patients’ time, increase errors and finally threaten patient’s safety. Many of them can be fixed with simple redesign solutions such as using clear labels and better layouts. This study suggests conducting further studies to confirm the findings concerning effect of evaluator experience on the results of Heuristic Evaluation. PMID:27081409

  17. An Expert System for Environmental Data Management.

    ERIC Educational Resources Information Center

    Berka, Petr; Jirku, Petr

    1995-01-01

    Examines the possibility of using expert system tools for environmental data management. Describes the domain-independent expert system shell SAK and Knowledge EXplorer, a system that learns rules from data. Demonstrates the functionality of Knowledge EXplorer on an example of water quality evaluation. (LZ)

  18. Independent Evaluation of California's Race to the Top: Early Learning Challenge Quality Rating and Improvement System. Half-Term Report

    ERIC Educational Resources Information Center

    Hawkinson, Laura E.; Quick, Heather E.; Muenchow, Susan; Anthony, Jennifer; Weinberg, Emily; Holod, Aleksandra; Parrish, Deborah; Meakin, John; Lee, Dong Hoon; Tarrant, Kate; Cannon, Jill S.; Zellman, Gail L.; Karoly, Lynn A.

    2015-01-01

    The first step in the Validity and Reliability Study summarizes the history and purpose of California's quality rating and improvement system (QRIS), reviews findings from other QRIS evaluation studies, and describes the approach to validating the system in California. The majority of this report focuses on providing context for the California…

  19. Federal Motor Carrier Safety Administration’s advanced system testing utilizing a data acquisition system on the highways (FAST DASH) safety technology evaluation project #3 : novel convex mirrors.

    DOT National Transportation Integrated Search

    2016-11-01

    An independent evaluation of a set of novel prototype mirrors was conducted to determine whether the mirrors perform as well as traditional production mirrors across the basic functions of field of view (FOV), image distortion, and distance estimatio...

  20. Passive sensor technology interface to assess elder activity in independent living.

    PubMed

    Alexander, Gregory L; Wakefield, Bonnie J; Rantz, Marilyn; Skubic, Marjorie; Aud, Myra A; Erdelez, Sanda; Ghenaimi, Said Al

    2011-01-01

    The effectiveness of clinical information systems to improve nursing and patient outcomes depends on human factors, including system usability, organizational workflow, and user satisfaction. The aim of this study was to examine to what extent residents, family members, and clinicians find a sensor data interface used to monitor elder activity levels usable and useful in an independent living setting. Three independent expert reviewers conducted an initial heuristic evaluation. Subsequently, 20 end users (5 residents, 5 family members, 5 registered nurses, and 5 physicians) participated in the evaluation. During the evaluation, each participant was asked to complete three scenarios taken from three residents. Morae recorder software was used to capture data during the user interactions. The heuristic evaluation resulted in 26 recommendations for interface improvement; these were classified under the headings content, aesthetic appeal, navigation, and architecture, which were derived from heuristic results. Total time for elderly residents to complete scenarios was much greater than for other users. Family members spent more time than clinicians but less time than residents did to complete scenarios. Elder residents and family members had difficulty interpreting clinical data and graphs, experienced information overload, and did not understand terminology. All users found the sensor data interface useful for identifying changing resident activities. Older adult users have special needs that should be addressed when designing clinical interfaces for them, especially information as important as health information. Evaluating human factors during user interactions with clinical information systems should be a requirement before implementation.

  1. Uranium resource assessment through statistical analysis of exploration geochemical and other data. Final report. [Codes EVAL, SURE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koch, G.S. Jr.; Howarth, R.J.; Schuenemeyer, J.H.

    1981-02-01

    We have developed a procedure that can help quadrangle evaluators to systematically summarize and use hydrogeochemical and stream sediment reconnaissance (HSSR) and occurrence data. Although we have not provided an independent estimate of uranium endowment, we have devised a methodology that will provide this independent estimate when additional calibration is done by enlarging the study area. Our statistical model for evaluation (system EVAL) ranks uranium endowment for each quadrangle. Because using this model requires experience in geology, statistics, and data analysis, we have also devised a simplified model, presented in the package SURE, a System for Uranium Resource Evaluation. Wemore » have developed and tested these models for the four quadrangles in southern Colorado that comprise the study area; to investigate their generality, the models should be applied to other quandrangles. Once they are calibrated with accepted uranium endowments for several well-known quadrangles, the models can be used to give independent estimates for less-known quadrangles. The point-oriented models structure the objective comparison of the quandrangles on the bases of: (1) Anomalies (a) derived from stream sediments, (b) derived from waters (stream, well, pond, etc.), (2) Geology (a) source rocks, as defined by the evaluator, (b) host rocks, as defined by the evaluator, and (3) Aerial radiometric anomalies.« less

  2. A methodology for evaluation of an interactive multispectral image processing system

    NASA Technical Reports Server (NTRS)

    Kovalick, William M.; Newcomer, Jeffrey A.; Wharton, Stephen W.

    1987-01-01

    Because of the considerable cost of an interactive multispectral image processing system, an evaluation of a prospective system should be performed to ascertain if it will be acceptable to the anticipated users. Evaluation of a developmental system indicated that the important system elements include documentation, user friendliness, image processing capabilities, and system services. The criteria and evaluation procedures for these elements are described herein. The following factors contributed to the success of the evaluation of the developmental system: (1) careful review of documentation prior to program development, (2) construction and testing of macromodules representing typical processing scenarios, (3) availability of other image processing systems for referral and verification, and (4) use of testing personnel with an applications perspective and experience with other systems. This evaluation was done in addition to and independently of program testing by the software developers of the system.

  3. Overcoming urban GPS navigation challenges through the use of MEMS inertial sensors and proper verification of navigation system performance

    NASA Astrophysics Data System (ADS)

    Vinande, Eric T.

    This research proposes several means to overcome challenges in the urban environment to ground vehicle global positioning system (GPS) receiver navigation performance through the integration of external sensor information. The effects of narrowband radio frequency interference and signal attenuation, both common in the urban environment, are examined with respect to receiver signal tracking processes. Low-cost microelectromechanical systems (MEMS) inertial sensors, suitable for the consumer market, are the focus of receiver augmentation as they provide an independent measure of motion and are independent of vehicle systems. A method for estimating the mounting angles of an inertial sensor cluster utilizing typical urban driving maneuvers is developed and is able to provide angular measurements within two degrees of truth. The integration of GPS and MEMS inertial sensors is developed utilizing a full state navigation filter. Appropriate statistical methods are developed to evaluate the urban environment navigation improvement due to the addition of MEMS inertial sensors. A receiver evaluation metric that combines accuracy, availability, and maximum error measurements is presented and evaluated over several drive tests. Following a description of proper drive test techniques, record and playback systems are evaluated as the optimal way of testing multiple receivers and/or integrated navigation systems in the urban environment as they simplify vehicle testing requirements.

  4. Final Evaluation Report 1976-77. Systemwide Evaluation. Publication Number: 76.70.

    ERIC Educational Resources Information Center

    Austin Independent School District, TX. Office of Research and Evaluation.

    A series of reports describes the activities of the Office of Research and Evaluation and compiles data descriptive of the Austin (Texas) Independent School District. This report describes the system-wide evaluation data for the school year 1976-77, which demonstrate improved performance in the basic skills areas of reading and mathematics,…

  5. An Independent Inter- and Intraobserver Agreement Evaluation of the AOSpine Subaxial Cervical Spine Injury Classification System.

    PubMed

    Urrutia, Julio; Zamora, Tomas; Yurac, Ratko; Campos, Mauricio; Palma, Joaquin; Mobarec, Sebastian; Prada, Carlos

    2017-03-01

    An agreement study. The aim of this study was to perform an independent interobserver and intraobserver agreement assessment of the AOSpine subaxial cervical spine injury classification system. The AOSpine subaxial cervical spine injury classification system was recently described. It showed substantial inter- and intraobserver agreement in the study describing it; however, an independent evaluation has not been performed. Anteroposterior and lateral radiographs, computed tomography scans, and magnetic resonance imaging of 65 patients with acute traumatic subaxial cervical spine injuries were selected and classified using the morphologic grading of the subaxial cervical spine injury classification system by 6 evaluators (3 spine surgeons and 3 orthopedic surgery residents). After a 6-week interval, the 65 cases were presented to the same evaluators in a random sequence for repeat evaluation. The kappa coefficient (κ) was used to determine the inter- and intraobserver agreement. The interobserver agreement was substantial when considering the fracture main types (A, B, C, or F), with κ = 0.61 (0.57-0.64), but moderate when considering the subtypes: κ = 0.57 (0.54-0.60). The intraobserver agreement was substantial considering the fracture types, with κ = 0.68 (0.62-0.74) and considering subtypes, κ = 0.62 (0.57-0.66). No significant differences were observed between spine surgeons and orthopedic residents in the overall inter- and intraobserver agreement, or in the inter- and intraobserver agreement of specific A, B, C, or F type of injuries. This classification allows adequate agreement among different observers and by the same observer on separate occasions. Future prospective studies should determine whether this classification allows surgeons to decide the best treatment for patients with subaxial cervical spine injuries. 3.

  6. Evaluation of exercise-respiratory system modifications and preliminary respiratory-circulatory system integration scheme

    NASA Technical Reports Server (NTRS)

    Gallagher, R. R.

    1974-01-01

    The respiratory control system, functioning as an independent system, is presented with modifications of the exercise subroutine. These modifications illustrate an improved control of ventilation rates and arterial and compartmental gas tensions. A very elementary approach to describing the interactions of the respiratory and circulatory system is presented.

  7. The Pfirrmann classification of lumbar intervertebral disc degeneration: an independent inter- and intra-observer agreement assessment.

    PubMed

    Urrutia, Julio; Besa, Pablo; Campos, Mauricio; Cikutovic, Pablo; Cabezon, Mario; Molina, Marcelo; Cruz, Juan Pablo

    2016-09-01

    Grading inter-vertebral disc degeneration (IDD) is important in the evaluation of many degenerative conditions, including patients with low back pain. Magnetic resonance imaging (MRI) is considered the best imaging instrument to evaluate IDD. The Pfirrmann classification is commonly used to grade IDD; the authors describing this classification showed an adequate agreement using it; however, there has been a paucity of independent agreement studies using this grading system. The aim of this study was to perform an independent inter- and intra-observer agreement study using the Pfirrmann classification. T2-weighted sagittal images of 79 patients consecutively studied with lumbar spine MRI were classified using the Pfirrmann grading system by six evaluators (three spine surgeons and three radiologists). After a 6-week interval, the 79 cases were presented to the same evaluators in a random sequence for repeat evaluation. The intra-class correlation coefficient (ICC) and the weighted kappa (wκ) were used to determine the inter- and intra-observer agreement. The inter-observer agreement was excellent, with an ICC = 0.94 (0.93-0.95) and wκ = 0.83 (0.74-0.91). There were no differences between spine surgeons and radiologists. Likewise, there were no differences in agreement evaluating the different lumbar discs. Most differences among observers were only of one grade. Intra-observer agreement was also excellent with ICC = 0.86 (0.83-0.89) and wκ = 0.89 (0.85-0.93). In this independent study, the Pfirrmann classification demonstrated an adequate agreement among different observers and by the same observer on separate occasions. Furthermore, it allows communication between radiologists and spine surgeons.

  8. Real-time optical holographic tracking of multiple objects

    NASA Technical Reports Server (NTRS)

    Chao, Tien-Hsin; Liu, Hua-Kuang

    1989-01-01

    A coherent optical correlation technique for real-time simultaneous tracking of several different objects making independent movements is described, and experimental results are presented. An evaluation of this system compared with digital computing systems is made. The real-time processing capability is obtained through the use of a liquid crystal television spatial light modulator and a dichromated gelatin multifocus hololens. A coded reference beam is utilized in the separation of the output correlation plane associated with each input target so that independent tracking can be achieved.

  9. Evaluation Design 1977-1978 ESEA Title VII Bilingual Program.

    ERIC Educational Resources Information Center

    Matuszek, Paula; And Others

    A design for the evaluation of ESEA Title VII bilingual programs in the Austin Independent School District is presented. The following topics are included: (1) Evaluation Design Review Form; (2) decision questions including the actual questions addressed on three levels: the Office of Education-Level, the system-level and the project-level; (3) a…

  10. An automatic speech recognition system with speaker-independent identification support

    NASA Astrophysics Data System (ADS)

    Caranica, Alexandru; Burileanu, Corneliu

    2015-02-01

    The novelty of this work relies on the application of an open source research software toolkit (CMU Sphinx) to train, build and evaluate a speech recognition system, with speaker-independent support, for voice-controlled hardware applications. Moreover, we propose to use the trained acoustic model to successfully decode offline voice commands on embedded hardware, such as an ARMv6 low-cost SoC, Raspberry PI. This type of single-board computer, mainly used for educational and research activities, can serve as a proof-of-concept software and hardware stack for low cost voice automation systems.

  11. Bounding the first exit from the basin: Independence times and finite-time basin stability

    NASA Astrophysics Data System (ADS)

    Schultz, Paul; Hellmann, Frank; Webster, Kevin N.; Kurths, Jürgen

    2018-04-01

    We study the stability of deterministic systems, given sequences of large, jump-like perturbations. Our main result is the derivation of a lower bound for the probability of the system to remain in the basin, given that perturbations are rare enough. This bound is efficient to evaluate numerically. To quantify rare enough, we define the notion of the independence time of such a system. This is the time after which a perturbed state has probably returned close to the attractor, meaning that subsequent perturbations can be considered separately. The effect of jump-like perturbations that occur at least the independence time apart is thus well described by a fixed probability to exit the basin at each jump, allowing us to obtain the bound. To determine the independence time, we introduce the concept of finite-time basin stability, which corresponds to the probability that a perturbed trajectory returns to an attractor within a given time. The independence time can then be determined as the time scale at which the finite-time basin stability reaches its asymptotic value. Besides that, finite-time basin stability is a novel probabilistic stability measure on its own, with potential broad applications in complex systems.

  12. Cooperative Intersection Collision Avoidance System for Violations (CICAS-V) : Database Structure

    DOT National Transportation Integrated Search

    2011-07-01

    This report documents the process required for data exchange between a conductor of a field operational test (FOT) and an independent evaluator based on the experience of the Cooperative Intersection Collision Avoidance System for Violations (CICAS-V...

  13. Health hazard evaluation report HETA 90-168-2248, Independence Police Department Indoor Range, Independence, Missouri

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rinehart, R.D.; Almaguer, D.; Klein, M.K.

    1992-08-01

    On February 14, 1990, the National Institute for Occupational Safety and Health (NIOSH) received a request from a management representative of the Independence, Missouri, Police Department Headquarters for a Health Hazard Evaluation. The Police Department requested NIOSH to evaluate the effectiveness of a newly redesigned air handling system installed inside their indoor firing range. On August 6, 1991, NIOSH investigators met with the firing range supervisor and toured the facility. On August 8, ten personal breathing-zone (PBZ) air samples and 3 area air samples were collected on filters inside the range and the filters were subsequently analyzed for lead bymore » atomic absorption spectroscopy (AAS). Surface lead contamination inside the firing range was measured in two locations and hand (dermal) lead contamination was measured on two instructors and two field officers. These samples were also analyzed for lead by AAS.« less

  14. Style-independent document labeling: design and performance evaluation

    NASA Astrophysics Data System (ADS)

    Mao, Song; Kim, Jong Woo; Thoma, George R.

    2003-12-01

    The Medical Article Records System or MARS has been developed at the U.S. National Library of Medicine (NLM) for automated data entry of bibliographical information from medical journals into MEDLINE, the premier bibliographic citation database at NLM. Currently, a rule-based algorithm (called ZoneCzar) is used for labeling important bibliographical fields (title, author, affiliation, and abstract) on medical journal article page images. While rules have been created for medical journals with regular layout types, new rules have to be manually created for any input journals with arbitrary or new layout types. Therefore, it is of interest to label any journal articles independent of their layout styles. In this paper, we first describe a system (called ZoneMatch) for automated generation of crucial geometric and non-geometric features of important bibliographical fields based on string-matching and clustering techniques. The rule based algorithm is then modified to use these features to perform style-independent labeling. We then describe a performance evaluation method for quantitatively evaluating our algorithm and characterizing its error distributions. Experimental results show that the labeling performance of the rule-based algorithm is significantly improved when the generated features are used.

  15. Striving for Independence: Two-Year Impact Findings from the Youth Villages Transitional Living Evaluation

    ERIC Educational Resources Information Center

    Skemer, Melanie; Valentine, Erin Jacobs

    2016-01-01

    Large numbers of young people in the United States were in foster care or in juvenile justice custody as teenagers, and many of them have a difficult time making a successful transition to independent adulthood as they leave these systems. Most of them faced a number of disadvantages during childhood and often have poor outcomes across several…

  16. Standardized and Repeatable Technology Evaluation for Cybersecurity Acquisition

    DTIC Science & Technology

    2017-02-01

    methodology for evaluating cybersecurity technologies. In this report, we introduce the Department of Defense (DoD)-centric and Independent Technology...Evaluation Capability (DITEC), an experimental decision support service within the U.S. DoD which aims to provide a standardized framework for...13 5.3.1 The Technology Matching Tool: A Recommender System for Security Non - Experts

  17. Oahu Wind Integration and Transmission Study (OWITS): Hawaiian Islands Transmission Interconnection Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodford, D.

    This report provides an independent review included an initial evaluation of the technical configuration and capital costs of establishing an undersea cable system and examining impacts to the existing electric transmission systems as a result of interconnecting the islands.

  18. Components of Standing Postural Control Evaluated in Pediatric Balance Measures: A Scoping Review.

    PubMed

    Sibley, Kathryn M; Beauchamp, Marla K; Van Ooteghem, Karen; Paterson, Marie; Wittmeier, Kristy D

    2017-10-01

    To identify measures of standing balance validated in pediatric populations, and to determine the components of postural control captured in each tool. Electronic searches of MEDLINE, Embase, and CINAHL databases using key word combinations of postural balance/equilibrium, psychometrics/reproducibility of results/predictive value of tests, and child/pediatrics; gray literature; and hand searches. Inclusion criteria were measures with a stated objective to assess balance, with pediatric (≤18y) populations, with at least 1 psychometric evaluation, with at least 1 standing task, with a standardized protocol and evaluation criteria, and published in English. Two reviewers independently identified studies for inclusion. There were 21 measures included. Two reviewers extracted descriptive characteristics, and 2 investigators independently coded components of balance in each measure using a systems perspective for postural control, an established framework for balance in pediatric populations. Components of balance evaluated in measures were underlying motor systems (100% of measures), anticipatory postural control (72%), static stability (62%), sensory integration (52%), dynamic stability (48%), functional stability limits (24%), cognitive influences (24%), verticality (9%), and reactive postural control (0%). Assessing children's balance with valid and comprehensive measures is important for ensuring development of safe mobility and independence with functional tasks. Balance measures validated in pediatric populations to date do not comprehensively assess standing postural control and omit some key components for safe mobility and independence. Existing balance measures, that have been validated in adult populations and address some of the existing gaps in pediatric measures, warrant consideration for validation in children. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  19. A Proposed Resource Cost Model Grant-in-Aid System in Illinois: Equity Considerations and Other Observations.

    ERIC Educational Resources Information Center

    Hickrod, G. Alan; Chaudhari, Ramesh B.

    This paper evaluates the equity dimensions of a grant-in-aid system based on the Resource Cost Model (RCM), as proposed by the Illinois State Board of Education. The first section is an independent evaluation of the conceptual and legal aspects of the RCM, focusing on both the weaknesses and the strengths of the model. In the second section, an…

  20. A risk-based auditing process for pharmaceutical manufacturers.

    PubMed

    Vargo, Susan; Dana, Bob; Rangavajhula, Vijaya; Rönninger, Stephan

    2014-01-01

    The purpose of this article is to share ideas on developing a risk-based model for the scheduling of audits (both internal and external). Audits are a key element of a manufacturer's quality system and provide an independent means of evaluating the manufacturer's or the supplier/vendor's compliance status. Suggestions for risk-based scheduling approaches are discussed in the article. Pharmaceutical manufacturers are required to establish and implement a quality system. The quality system is an organizational structure defining responsibilities, procedures, processes, and resources that the manufacturer has established to ensure quality throughout the manufacturing process. Audits are a component of the manufacturer's quality system and provide a systematic and an independent means of evaluating the manufacturer's overall quality system and compliance status. Audits are performed at defined intervals for a specified duration. The intention of the audit process is to focus on key areas within the quality system and may not cover all relevant areas during each audit. In this article, the authors provide suggestions for risk-based scheduling approaches to aid pharmaceutical manufacturers in identifying the key focus areas for an audit.

  1. A Documentation System to Save Time and Ensure Proper Application of the Fiberoptic Endoscopic Evaluation of Swallowing (FEES®)

    PubMed Central

    Hey, Christiane; Pluschinski, Petra; Stanschus, Soenke; Euler, Harald A.; Sader, Robert A.; Langmore, Susan; Neumann, Katrin

    2011-01-01

    A properly performed fiberoptic endoscopic evaluation of swallowing (FEES®) is comprehensive and time-consuming. Editing times of FEES protocols and attempts for efficiency maximization are unknown. Here, the protocol editing times of completed FEES examinations were determined. The present study reports the time savings and quality gains of a newly developed documentation system tailored to the FEES standard of Langmore. Four independent examiners analyzed twelve videos of FEES procedures, six without and six with the documentation system. Effectiveness of the documentation system was evaluated according to the times for total evaluation, interpretation, documentation, report writing, and for report completeness. The documentation system reduced editing times and increased report completeness with large effect sizes. Averaged total evaluation time decreased from 42 to 27 min, report completeness increased from 55 to 80%. The use of the documentation system facilitates and improves the assessment of the swallowing process. PMID:20938202

  2. Report on Career Pathways: A Success Story in Berrien County, Michigan.

    ERIC Educational Resources Information Center

    Rudy, Dennis W.; Rudy, Ellen L.

    Independent evaluators examined the progress of the Berrien County Intermediate School District in Berrien County, Michigan, in implementing Michigan's Career Preparation System. The evaluation established that the district has provided the leadership, training, resources, and continued support to implement a systemwide school-to-career reform…

  3. Professional Personnel Evaluation System: 1983-84 Final Technical Report.

    ERIC Educational Resources Information Center

    Doss, David A.

    This technical report summarizes the evaluation ratings given to professionals on probation or up for contract renewal in the Austin Independent School District. Graphs, tables, and rankings are presented for each specified population: all district teachers combined; teachers by school level (elementary, junior high, senior high); teachers by…

  4. Evaluation of the Guided Occupational Orientation-Training and Job Placement Project Syracuse City School District.

    ERIC Educational Resources Information Center

    Holder, Harold D.; And Others

    The report provides a summary of the independent, third party evaluation of the 1972-73 funding year of the Guided Occupational Orientation Project of the Syracuse City School District. A systems approach to evaluation was utilized in this effort. The funded project involved all three grade populations--elementary, junior high school, and senior…

  5. Independent Orbiter Assessment (IOA): Analysis of the life support and airlock support subsystems

    NASA Technical Reports Server (NTRS)

    Arbet, Jim; Duffy, R.; Barickman, K.; Saiidi, Mo J.

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Life Support System (LSS) and Airlock Support System (ALSS). Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. The LSS provides for the management of the supply water, collection of metabolic waste, management of waste water, smoke detection, and fire suppression. The ALSS provides water, oxygen, and electricity to support an extravehicular activity in the airlock.

  6. Independent Orbiter Assessment (IOA): Analysis of the extravehicular mobility unit

    NASA Technical Reports Server (NTRS)

    Raffaelli, Gary G.

    1986-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items (PCIs). To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Extravehicular Mobility Unit (EMU) hardware. The EMU is an independent anthropomorphic system that provides environmental protection, mobility, life support, and communications for the Shuttle crewmember to perform Extravehicular Activity (EVA) in Earth orbit. Two EMUs are included on each baseline Orbiter mission, and consumables are provided for three two-man EVAs. The EMU consists of the Life Support System (LSS), Caution and Warning System (CWS), and the Space Suit Assembly (SSA). Each level of hardware was evaluated and analyzed for possible failure modes and effects. The majority of these PCIs are resultant from failures which cause loss of one or more primary functions: pressurization, oxygen delivery, environmental maintenance, and thermal maintenance. It should also be noted that the quantity of PCIs would significantly increase if the SOP were to be treated as an emergency system rather than as an unlike redundant element.

  7. Phase 2 Report: Oahu Wind Integration and Transmission Study (OWITS); Hawaiian Islands Transmission Interconnection Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodford, D.

    This report provides an independent review including an initial evaluation of the technical configuration and capital costs of establishing an undersea cable system and examining impacts to the existing electric transmission systems as a result of interconnecting the islands

  8. SIGPI. Fault Tree Cut Set System Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patenaude, C.J.

    1992-01-13

    SIGPI computes the probabilistic performance of complex systems by combining cut set or other binary product data with probability information on each basic event. SIGPI is designed to work with either coherent systems, where the system fails when certain combinations of components fail, or noncoherent systems, where at least one cut set occurs only if at least one component of the system is operating properly. The program can handle conditionally independent components, dependent components, or a combination of component types and has been used to evaluate responses to environmental threats and seismic events. The three data types that can bemore » input are cut set data in disjoint normal form, basic component probabilities for independent basic components, and mean and covariance data for statistically dependent basic components.« less

  9. SIGPI. Fault Tree Cut Set System Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patenaude, C.J.

    1992-01-14

    SIGPI computes the probabilistic performance of complex systems by combining cut set or other binary product data with probability information on each basic event. SIGPI is designed to work with either coherent systems, where the system fails when certain combinations of components fail, or noncoherent systems, where at least one cut set occurs only if at least one component of the system is operating properly. The program can handle conditionally independent components, dependent components, or a combination of component types and has been used to evaluate responses to environmental threats and seismic events. The three data types that can bemore » input are cut set data in disjoint normal form, basic component probabilities for independent basic components, and mean and covariance data for statistically dependent basic components.« less

  10. Independent Orbiter Assessment (IOA): Analysis of the purge, vent and drain subsystem

    NASA Technical Reports Server (NTRS)

    Bynum, M. C., III

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter PV and D (Purge, Vent and Drain) Subsystem hardware. The PV and D Subsystem controls the environment of unpressurized compartments and window cavities, senses hazardous gases, and purges Orbiter/ET Disconnect. The subsystem is divided into six systems: Purge System (controls the environment of unpressurized structural compartments); Vent System (controls the pressure of unpressurized compartments); Drain System (removes water from unpressurized compartments); Hazardous Gas Detection System (HGDS) (monitors hazardous gas concentrations); Window Cavity Conditioning System (WCCS) (maintains clear windows and provides pressure control of the window cavities); and External Tank/Orbiter Disconnect Purge System (prevents cryo-pumping/icing of disconnect hardware). Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Four of the sixty-two failure modes analyzed were determined as single failures which could result in the loss of crew or vehicle. A possible loss of mission could result if any of twelve single failures occurred. Two of the criticality 1/1 failures are in the Window Cavity Conditioning System (WCCS) outer window cavity, where leakage and/or restricted flow will cause failure to depressurize/repressurize the window cavity. Two criticality 1/1 failures represent leakage and/or restricted flow in the Orbiter/ET disconnect purge network which prevent cryopumping/icing of disconnect hardware. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.

  11. Working Memory Systems in the Rat.

    PubMed

    Bratch, Alexander; Kann, Spencer; Cain, Joshua A; Wu, Jie-En; Rivera-Reyes, Nilda; Dalecki, Stefan; Arman, Diana; Dunn, Austin; Cooper, Shiloh; Corbin, Hannah E; Doyle, Amanda R; Pizzo, Matthew J; Smith, Alexandra E; Crystal, Jonathon D

    2016-02-08

    A fundamental feature of memory in humans is the ability to simultaneously work with multiple types of information using independent memory systems. Working memory is conceptualized as two independent memory systems under executive control [1, 2]. Although there is a long history of using the term "working memory" to describe short-term memory in animals, it is not known whether multiple, independent memory systems exist in nonhumans. Here, we used two established short-term memory approaches to test the hypothesis that spatial and olfactory memory operate as independent working memory resources in the rat. In the olfactory memory task, rats chose a novel odor from a gradually incrementing set of old odors [3]. In the spatial memory task, rats searched for a depleting food source at multiple locations [4]. We presented rats with information to hold in memory in one domain (e.g., olfactory) while adding a memory load in the other domain (e.g., spatial). Control conditions equated the retention interval delay without adding a second memory load. In a further experiment, we used proactive interference [5-7] in the spatial domain to compromise spatial memory and evaluated the impact of adding an olfactory memory load. Olfactory and spatial memory are resistant to interference from the addition of a memory load in the other domain. Our data suggest that olfactory and spatial memory draw on independent working memory systems in the rat. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Using Discrete Event Simulation to Model Attacker Interactions with Cyber and Physical Security Systems

    DOE PAGES

    Perkins, Casey; Muller, George

    2015-10-08

    The number of connections between physical and cyber security systems is rapidly increasing due to centralized control from automated and remotely connected means. As the number of interfaces between systems continues to grow, the interactions and interdependencies between them cannot be ignored. Historically, physical and cyber vulnerability assessments have been performed independently. This independent evaluation omits important aspects of the integrated system, where the impacts resulting from malicious or opportunistic attacks are not easily known or understood. Here, we describe a discrete event simulation model that uses information about integrated physical and cyber security systems, attacker characteristics and simple responsemore » rules to identify key safeguards that limit an attacker's likelihood of success. Key features of the proposed model include comprehensive data generation to support a variety of sophisticated analyses, and full parameterization of safeguard performance characteristics and attacker behaviours to evaluate a range of scenarios. Lastly, we also describe the core data requirements and the network of networks that serves as the underlying simulation structure.« less

  13. Using Discrete Event Simulation to Model Attacker Interactions with Cyber and Physical Security Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perkins, Casey; Muller, George

    The number of connections between physical and cyber security systems is rapidly increasing due to centralized control from automated and remotely connected means. As the number of interfaces between systems continues to grow, the interactions and interdependencies between them cannot be ignored. Historically, physical and cyber vulnerability assessments have been performed independently. This independent evaluation omits important aspects of the integrated system, where the impacts resulting from malicious or opportunistic attacks are not easily known or understood. Here, we describe a discrete event simulation model that uses information about integrated physical and cyber security systems, attacker characteristics and simple responsemore » rules to identify key safeguards that limit an attacker's likelihood of success. Key features of the proposed model include comprehensive data generation to support a variety of sophisticated analyses, and full parameterization of safeguard performance characteristics and attacker behaviours to evaluate a range of scenarios. Lastly, we also describe the core data requirements and the network of networks that serves as the underlying simulation structure.« less

  14. NREL Validates $1-Million H-Prize Submission for DOE | News | NREL

    Science.gov Websites

    H2 Refuel H-Prize Competition to develop a home hydrogen fueling system. NREL acted as the independent validator for the competition by collecting and analyzing three months of system performance data per day, system availability, and cost. To ensure data integrity and impartial evaluation of the

  15. 77 FR 43089 - Evaluation of an Up-and-Down Procedure for Acute Dermal Systemic Toxicity Testing: Request for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-23

    ... Systemic Toxicity Testing: Request for Nominations for an Independent Expert Panel and Submission of... systemic toxicity testing. NICEATM requests nominations of scientific experts who can be considered for the...) Test Guideline 425 in 2001 (OECD, 2001). The oral UDP reduces animal use by up to 70% compared to the...

  16. A new pneumatic suspension system with independent stiffness and ride height tuning capabilities

    NASA Astrophysics Data System (ADS)

    Yin, Zhihong; Khajepour, Amir; Cao, Dongpu; Ebrahimi, Babak; Guo, Konghui

    2012-12-01

    This paper introduces a new pneumatic spring for vehicle suspension systems, allowing independent tuning of stiffness and ride height according to different vehicle operating conditions and driver preferences. The proposed pneumatic spring comprises a double-acting pneumatic cylinder, two accumulators and a tuning subsystem. This paper presents a detailed description of the pneumatic spring and its working principle. The mathematical model is established based on principles of thermo and fluid dynamics. An experimental setup has been designed and fabricated for testing and evaluating the proposed pneumatic spring. The analytical and experimental results confirm the capability of the new pneumatic spring system for independent tuning of stiffness and ride height. The mathematical model is verified and the capabilities of the pneumatic spring are further proved. It is concluded that this new pneumatic spring provides a more flexible suspension design alternative for meeting various conflicting suspension requirements for ride comfort and performance.

  17. Choice of optical system is critical for the security of double random phase encryption systems

    NASA Astrophysics Data System (ADS)

    Muniraj, Inbarasan; Guo, Changliang; Malallah, Ra'ed; Cassidy, Derek; Zhao, Liang; Ryle, James P.; Healy, John J.; Sheridan, John T.

    2017-06-01

    The linear canonical transform (LCT) is used in modeling a coherent light-field propagation through first-order optical systems. Recently, a generic optical system, known as the quadratic phase encoding system (QPES), for encrypting a two-dimensional image has been reported. In such systems, two random phase keys and the individual LCT parameters (α,β,γ) serve as secret keys of the cryptosystem. It is important that such encryption systems also satisfy some dynamic security properties. We, therefore, examine such systems using two cryptographic evaluation methods, the avalanche effect and bit independence criterion, which indicate the degree of security of the cryptographic algorithms using QPES. We compared our simulation results with the conventional Fourier and the Fresnel transform-based double random phase encryption (DRPE) systems. The results show that the LCT-based DRPE has an excellent avalanche and bit independence characteristics compared to the conventional Fourier and Fresnel-based encryption systems.

  18. Independent Peer Evaluation of the Large Area Crop Inventory Experiment (LACIE): The LACIE Symposium

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Yield models and crop estimate accuracy are discussed within the Large Area Crop Inventory Experiment. The wheat yield estimates in the United States, Canada, and U.S.S.R. are emphasized. Experimental results design, system implementation, data processing systems, and applications were considered.

  19. Funding of Medical Research in Australia by the National Health & Medical Research Council.

    ERIC Educational Resources Information Center

    McCloskey, Ian

    1994-01-01

    The role of Australia's National Health and Medical Research Council, an independent statutory body, in distribution of funds for research projects, programs, units, and major institutes. The agency's evaluation system, resource allocation practices, and training and career support system are described briefly. (MSE)

  20. Fleximode: Within Western Australia TAFE.

    ERIC Educational Resources Information Center

    Toussaint, Dorothy

    After fleximode was introduced into the Western Australian TAFE system, its cost and effectiveness compared with traditional delivery systems were evaluated. Fleximode, as practiced in Australia, was adapted from a mode of study pioneered in England. It offered students the independence of off-campus study in combination with access to college…

  1. Pilot Project to Optimize Ground Water Remediation Systems at RCRA Corrective Action Facilities: Summary Report and Lessons Learned

    EPA Pesticide Factsheets

    Based on previous success with conducting independent optimization evaluations at Fund-lead pump and treat sites (i.e., those sites with pump and treat systems funded and managed by Superfund and the States), the EPA Office of Superfund .....

  2. Subjective Performance Evaluation in the Public Sector: Evidence from School Inspections. CEE DP 135

    ERIC Educational Resources Information Center

    Hussain, Iftikhar

    2012-01-01

    Performance measurement in the public sector is largely based on objective metrics, which may be subject to gaming behaviour. This paper investigates a novel subjective performance evaluation system where independent inspectors visit schools at very short notice, publicly disclose their findings and sanction schools rated fail. First, I…

  3. Using the systems framework for postural control to analyze the components of balance evaluated in standardized balance measures: a scoping review.

    PubMed

    Sibley, Kathryn M; Beauchamp, Marla K; Van Ooteghem, Karen; Straus, Sharon E; Jaglal, Susan B

    2015-01-01

    To identify components of postural control included in standardized balance measures for adult populations. Electronic searches of MEDLINE, EMBASE, and CINAHL databases using keyword combinations of postural balance/equilibrium, psychometrics/reproducibility of results/predictive value of tests/validation studies, instrument construction/instrument validation, geriatric assessment/disability evaluation, gray literature, and hand searches. Inclusion criteria were measures with a stated objective to assess balance, adult populations (18y and older), at least 1 psychometric evaluation, 1 standing task, a standardized protocol and evaluation criteria, and published in English. Two reviewers independently identified studies for inclusion. Sixty-six measures were included. A research assistant extracted descriptive characteristics and 2 reviewers independently coded components of balance in each measure using the Systems Framework for Postural Control, a widely recognized model of balance. Components of balance evaluated in these measures were underlying motor systems (100% of measures), anticipatory postural control (71%), dynamic stability (67%), static stability (64%), sensory integration (48%), functional stability limits (27%), reactive postural control (23%), cognitive influences (17%), and verticality (8%). Thirty-four measures evaluated 3 or fewer components of balance, and 1 measure-the Balance Evaluation Systems Test-evaluated all components of balance. Several standardized balance measures provide only partial information on postural control and omit important components of balance related to avoiding falls. As such, the choice of measure(s) may limit the overall interpretation of an individual's balance ability. Continued work is necessary to increase the implementation of comprehensive balance assessment in research and practice. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  4. Proposed test method for and evaluation of wheelchair seating system (WCSS) crashworthiness.

    PubMed

    van Roosmalen, L; Bertocci, G; Ha, D R; Karg, P; Szobota, S

    2000-01-01

    Safety of motor vehicle seats is of great importance in providing crash protection to the occupant. An increasing number of wheelchair users use their wheelchairs as motor vehicle seats when traveling. A voluntary standard requires that compliant wheelchairs be dynamically sled impact tested. However, testing to evaluate the crashworthiness of add-on wheelchair seating systems (WCSS) independent of their wheelchair frame is not addressed by this standard. To address this need, this study developed a method to evaluate the crash-worthiness of WCSS with independent frames. Federal Motor Vehicle Safety Standards (FMVSS) 207 test protocols, used to test the strength of motor vehicle seats, were modified and used to test the strength of three WCSS. Forward and rearward loads were applied at the WCSS center of gravity (CGSS), and a moment was applied at the uppermost point of the seat back. Each of the three tested WCSS met the strength requirements of FMVSS 207. Wheelchair seat-back stiffness was also investigated and compared to motor vehicle seat-back stiffness.

  5. Independent Quality Control Review of EPA OIG Operations

    EPA Pesticide Factsheets

    The review considers selected audit work performed by EPA OIG, Office of Audit, Congressional and Public Liaison, Mission Systems, and Program Evaluation, during the period for 1 October 2006 through 30 September 2007 .

  6. Thermal power systems small power systems applications project. Decision analysis for evaluating and ranking small solar thermal power system technologies. Volume 1: A brief introduction to multiattribute decision analysis. [explanation of multiattribute decision analysis methods used in evaluating alternatives for small powered systems

    NASA Technical Reports Server (NTRS)

    Feinberg, A.; Miles, R. F., Jr.

    1978-01-01

    The principal concepts of the Keeney and Raiffa approach to multiattribute decision analysis are described. Topics discussed include the concepts of decision alternatives, outcomes, objectives, attributes and their states, attribute utility functions, and the necessary independence properties for the attribute states to be aggregated into a numerical representation of the preferences of the decision maker for the outcomes and decision alternatives.

  7. Java Mission Evaluation Workstation System

    NASA Technical Reports Server (NTRS)

    Pettinger, Ross; Watlington, Tim; Ryley, Richard; Harbour, Jeff

    2006-01-01

    The Java Mission Evaluation Workstation System (JMEWS) is a collection of applications designed to retrieve, display, and analyze both real-time and recorded telemetry data. This software is currently being used by both the Space Shuttle Program (SSP) and the International Space Station (ISS) program. JMEWS was written in the Java programming language to satisfy the requirement of platform independence. An object-oriented design was used to satisfy additional requirements and to make the software easily extendable. By virtue of its platform independence, JMEWS can be used on the UNIX workstations in the Mission Control Center (MCC) and on office computers. JMEWS includes an interactive editor that allows users to easily develop displays that meet their specific needs. The displays can be developed and modified while viewing data. By simply selecting a data source, the user can view real-time, recorded, or test data.

  8. Findings from a participatory evaluation of a smart home application for older adults.

    PubMed

    Demiris, George; Oliver, Debra Parker; Dickey, Geraldine; Skubic, Marjorie; Rantz, Marilyn

    2008-01-01

    The aim of this paper is to present a participatory evaluation of an actual "smart home" project implemented in an independent retirement facility. Using the participatory evaluation process, residents guided the research team through development and implementation of the initial phase of a smart home project designed to assist residents to remain functionally independent and age in place. We recruited nine residents who provided permission to install the technology in their apartments. We conducted a total of 75 interviews and three observational sessions. Residents expressed overall positive perceptions of the sensor technologies and did not feel that these interfered with their daily activities. The process of adoption and acceptance of the sensors included three phases, familiarization, adjustment and curiosity, and full integration. Residents did not express privacy concerns. They provided detailed feedback and suggestions that were integrated into the redesign of the system. They also reported a sense of control resulting from their active involvement in the evaluation process. Observational sessions confirmed that the sensors were not noticeable and residents did not change their routines. The participatory evaluation approach not only empowers end-users but it also allows for the implementation of smart home systems that address residents' needs.

  9. Independent Orbiter Assessment (IOA): Analysis of the auxiliary power unit

    NASA Technical Reports Server (NTRS)

    Barnes, J. E.

    1986-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Auxiliary Power Unit (APU). The APUs are required to provide power to the Orbiter hydraulics systems during ascent and entry flight phases for aerosurface actuation, main engine gimballing, landing gear extension, and other vital functions. For analysis purposes, the APU system was broken down into ten functional subsystems. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. A preponderance of 1/1 criticality items were related to failures that allowed the hydrazine fuel to escape into the Orbiter aft compartment, creating a severe fire hazard, and failures that caused loss of the gas generator injector cooling system.

  10. The conical scanner evaluation system design

    NASA Technical Reports Server (NTRS)

    Cumella, K. E.; Bilanow, S.; Kulikov, I. B.

    1982-01-01

    The software design for the conical scanner evaluation system is presented. The purpose of this system is to support the performance analysis of the LANDSAT-D conical scanners, which are infrared horizon detection attitude sensors designed for improved accuracy. The system consists of six functionally independent subsystems and five interface data bases. The system structure and interfaces of each of the subsystems is described and the content, format, and file structure of each of the data bases is specified. For each subsystem, the functional logic, the control parameters, the baseline structure, and each of the subroutines are described. The subroutine descriptions include a procedure definition and the input and output parameters.

  11. [Barriers for introducing a health technology assessment organization to inform health care decision-making in the Spanish National Health System].

    PubMed

    Artells, Juan José; Peiró, Salvador; Meneu, Ricard

    2014-01-01

    To identify difficulties, obstacles and limitations to establish an organizational structure devoted to the evaluation of healthcare technologies for incorporation, maintenance or removal from the services portfolio of the Spanish National Health System (sNHS). Panel of 14 experts, structured according to processes adapted from brainstorming, nominal group, and Rand consensus method techniques. The panel proposed 77 items as potential obstacles to the establishment of an official and independent "agency" able to inform on sNHS healthcare benefits funding or selective disinvestment. These items were focused on: 1) lack of political motivation to introduce the cost-effectiveness analysis from the state and regional governments and lack of independence and transparency of the evaluation processes, 2) the tension between a decentralized health system and evaluation activities with significant scale economies, 3) technical difficulties of the evaluation processes, including their ability to influence decision making and 4) social and professional refusal to the exclusion of healthcare benefits when it is perceived as indiscriminate. Although there is a different number and type of obstacles for developing the capacity of the sNHS to include or exclude healthcare benefits based on the evaluation of their effectiveness and efficiency, experts place in the political arena (political motivation, transparency, governance) the main difficulties to advance in this field.

  12. Findings from an Independent Evaluation of the AMNH's Online Seminars on Science Course: "The Solar System"

    ERIC Educational Resources Information Center

    Inverness Research, 2009

    2009-01-01

    Inverness Research studied the American Museum of Natural History (AMNH) Seminars on Science program for eight years, from its inception in 1998 to 2006. In 2009, Inverness Research conducted additional studies of the AMNH's new online course, The Solar System. This paper presents teacher survey ratings for The Solar System, along with profiles of…

  13. Design and Evaluation of an Interactive Exercise Coaching System for Older Adults: Lessons Learned

    PubMed Central

    Ofli, Ferda; Kurillo, Gregorij; Obdržálek, Štěpán; Bajcsy, Ruzena; Jimison, Holly; Pavel, Misha

    2016-01-01

    Although the positive effects of exercise on the well-being and quality of independent living for older adults are well-accepted, many elderly individuals lack access to exercise facilities, or the skills and motivation to perform exercise at home. To provide a more engaging environment that promotes physical activity, various fitness applications have been proposed. Many of the available products, however, are geared toward a younger population and are not appropriate or engaging for an older population. To address these issues, we developed an automated interactive exercise coaching system using the Microsoft Kinect. The coaching system guides users through a series of video exercises, tracks and measures their movements, provides real-time feedback, and records their performance over time. Our system consists of exercises to improve balance, flexibility, strength, and endurance, with the aim of reducing fall risk and improving performance of daily activities. In this paper, we report on the development of the exercise system, discuss the results of our recent field pilot study with six independently-living elderly individuals, and highlight the lessons learned relating to the in-home system setup, user tracking, feedback, and exercise performance evaluation. PMID:25594988

  14. Evaluating Feynman integrals by the hypergeometry

    NASA Astrophysics Data System (ADS)

    Feng, Tai-Fu; Chang, Chao-Hsi; Chen, Jian-Bin; Gu, Zhi-Hua; Zhang, Hai-Bin

    2018-02-01

    The hypergeometric function method naturally provides the analytic expressions of scalar integrals from concerned Feynman diagrams in some connected regions of independent kinematic variables, also presents the systems of homogeneous linear partial differential equations satisfied by the corresponding scalar integrals. Taking examples of the one-loop B0 and massless C0 functions, as well as the scalar integrals of two-loop vacuum and sunset diagrams, we verify our expressions coinciding with the well-known results of literatures. Based on the multiple hypergeometric functions of independent kinematic variables, the systems of homogeneous linear partial differential equations satisfied by the mentioned scalar integrals are established. Using the calculus of variations, one recognizes the system of linear partial differential equations as stationary conditions of a functional under some given restrictions, which is the cornerstone to perform the continuation of the scalar integrals to whole kinematic domains numerically with the finite element methods. In principle this method can be used to evaluate the scalar integrals of any Feynman diagrams.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    The GATEWAY program evaluated a trial installation of tunable-white LED lighting systems in three classrooms in the Carrollton-Farmers Branch Independent School District in Carrollton, TX. The report provides valuable insights into the use of this technology in a real-world setting.

  16. Independent Evaluation: Insights from Public Accounting

    ERIC Educational Resources Information Center

    Brown, Abigail B.; Klerman, Jacob Alex

    2012-01-01

    Background: Maintaining the independence of contract government program evaluation presents significant contracting challenges. The ideal outcome for an agency is often both the impression of an independent evaluation "and" a glowing report. In this, independent evaluation is like financial statement audits: firm management wants both a public…

  17. DITEC: Technology Matching Tool (TMT)

    DTIC Science & Technology

    2016-08-01

    of cyberattacks, cybersecurity has become one of the Department of Defense’s (DoD) top priorities. The marketplace of cybersecurity technologies is... cybersecurity products and services. The Space and Naval Warfare Systems Center Pacific’s (SSC Pacific) IA Division has developed the DoD-Centric and...Independent Technology Evaluation Capability (DITEC) to streamline cybersecurity technology evaluation. Specifically, DITEC defines a process for

  18. Evaluation of the Navys Sea/Shore Flow Policy

    DTIC Science & Technology

    2016-06-01

    Std. Z39.18 i Abstract CNA developed an independent Discrete -Event Simulation model to evaluate and assess the effect of...a more steady manning level, but the variability remains, even if the system is optimized. In building a Discrete -Event Simulation model, we...steady-state model. In FY 2014, CNA developed a Discrete -Event Simulation model to evaluate the impact of sea/shore flow policy (the DES-SSF model

  19. LOOP: Linking Outcomes to Organizational Planning, First Quarterly Report: 25 School Board Priorities.

    ERIC Educational Resources Information Center

    Ligon, Glynn; Wicker, Maria L. R.

    The Austin Independent School District Superintendent of Schools required a process for monitoring district activities. The Office of Research and Evaluation developed LOOP (Linking Outcomes to Organizational Planning). LOOP is a management information system through which progress in a number of activities within the school system may be…

  20. Application of the Virginia STEPS (Student/Teacher Education Planning System) by Basic Skills Education Teachers.

    ERIC Educational Resources Information Center

    Seguin, Barbara; Swanson, Lois

    The Virginia STEPS (Student/Teacher Education Planning System) was developed to enable adult basic education (ABE) students to become independent learners responsible for planning, carrying out, evaluating, and making adjustments in their education. ABE instructors at Blackhawk Technical College in Wisconsin have adapted the STEPS model to make…

  1. Teaching Children with Autism to Engage in Peer-Directed Mands Using a Picture Exchange Communication System

    ERIC Educational Resources Information Center

    Paden, Amber R.; Kodak, Tiffany; Fisher, Wayne W.; Gawley-Bullington, Elizabeth M.; Bouxsein, Kelly J.

    2012-01-01

    We evaluated differential reinforcement of alternative behavior (DRA) plus prompting to increase peer-directed mands for preferred items using a picture exchange communication system (PECS). Two nonvocal individuals with autism participated. Independent mands with a peer increased with the implementation of DRA plus prompting for both…

  2. Applying usability heuristics to radiotherapy systems.

    PubMed

    Chan, Alvita J; Islam, Mohammad K; Rosewall, Tara; Jaffray, David A; Easty, Anthony C; Cafazzo, Joseph A

    2012-01-01

    Heuristic evaluations have been used to evaluate safety of medical devices by identifying and assessing usability issues. Since radiotherapy treatment delivery systems often consist of multiple complex user-interfaces, a heuristic evaluation was conducted to assess the potential safety issues of such a system. A heuristic evaluation was conducted to evaluate the treatment delivery system at Princess Margaret Hospital (Toronto, Canada). Two independent evaluators identified usability issues with the user-interfaces and rated the severity of each issue. The evaluators identified 75 usability issues in total. Eighteen of them were rated as high severity, indicating the potential to have a major impact on patient safety. A majority of issues were found on the record and verify system, and many were associated with the patient setup process. While the hospital has processes in place to ensure patient safety, recommendations were developed to further mitigate the risks of potential consequences. Heuristic evaluation is an efficient and inexpensive method that can be successfully applied to radiotherapy delivery systems to identify usability issues and improve patient safety. Although this study was conducted only at one site, the findings may have broad implications for the design of these systems. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  3. Usefulness of an Internet-based thematic learning network: comparison of effectiveness with traditional teaching.

    PubMed

    Coma Del Corral, María Jesús; Guevara, José Cordero; Luquin, Pedro Abáigar; Peña, Horacio J; Mateos Otero, Juan José

    2006-03-01

    UniNet is an Internet-based thematic network for a virtual community of users (VCU). It supports one multidisciplinary community of doctoral students, who receive most of the courses on the network. The evident advantages of distance learning by Internet, in terms of costs, comfort, etc., require a previous evaluation of the system, focusing on the learning outcomes of the student. The aim was to evaluate the real learning of the students of doctorate courses, by comparing the effectiveness of distance learning in UniNet with traditional classroom-based teaching. Five doctorate courses were taught simultaneously to two independent groups of students in two ways: one, through the UniNet Network, and the other in a traditional classroom. The academic knowledge of students was evaluated at the beginning and end of each course. The difference in score was considered as a knowledge increase. The comparison was made using Student's t-test for independent groups. There were no significant statistical differences in the outcomes of the two groups of students. This suggests that both teaching systems were equivalent in increasing the knowledge of the students. Both educational methods, the traditional system and the online system in a thematic network, are effective and similar for increasing knowledge.

  4. Independent Orbiter Assessment (IOA): Analysis of the Orbiter Experiment (OEX) subsystem

    NASA Technical Reports Server (NTRS)

    Compton, J. M.

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Experiments hardware. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. The Orbiter Experiments (OEX) Program consists of a multiple set of experiments for the purpose of gathering environmental and aerodynamic data to develop more accurate ground models for Shuttle performance and to facilitate the design of future spacecraft. This assessment only addresses currently manifested experiments and their support systems. Specifically this list consists of: Shuttle Entry Air Data System (SEADS); Shuttle Upper Atmosphere Mass Spectrometer (SUMS); Forward Fuselage Support System for OEX (FFSSO); Shuttle Infrared Laced Temperature Sensor (SILTS); Aerodynamic Coefficient Identification Package (ACIP); and Support System for OEX (SSO). There are only two potential critical items for the OEX, since the experiments only gather data for analysis post mission and are totally independent systems except for power. Failure of any experiment component usually only causes a loss of experiment data and in no way jeopardizes the crew or mission.

  5. Usability evaluation of Laboratory and Radiology Information Systems integrated into a hospital information system.

    PubMed

    Nabovati, Ehsan; Vakili-Arki, Hasan; Eslami, Saeid; Khajouei, Reza

    2014-04-01

    This study was conducted to evaluate the usability of widely used laboratory and radiology information systems. Three usability experts independently evaluated the user interfaces of Laboratory and Radiology Information Systems using heuristic evaluation method. They applied Nielsen's heuristics to identify and classify usability problems and Nielsen's severity rating to judge their severity. Overall, 116 unique heuristic violations were identified as usability problems. In terms of severity, 67 % of problems were rated as major and catastrophic. Among 10 heuristics, "consistency and standards" was violated most frequently. Moreover, mean severity of problems concerning "error prevention" and "help and documentation" heuristics was higher than of the others. Despite widespread use of specific healthcare information systems, they suffer from usability problems. Improving the usability of systems by following existing design standards and principles from the early phased of system development life cycle is recommended. Especially, it is recommended that the designers design systems that inhibit the initiation of erroneous actions and provide sufficient guidance to users.

  6. Orbiter global positioning system design and Ku-band problems investigation, exhibit B, revision 1

    NASA Technical Reports Server (NTRS)

    Chie, C. M.; Braun, W. R.

    1981-01-01

    The LinCom effort in supporting the JSC study of the use of the Global Positioning System (GPS) on the space shuttle and in Ku-band problem investigation is documented. LinCom was tasked to evaluate system implementation, performance, and integration aspects of the shuttle GPS and to provide independent technical assessment of reports submitted to JSC regarding integration studies, system studies and navigation analyses.

  7. Imitating manual curation of text-mined facts in biomedicine.

    PubMed

    Rodriguez-Esteban, Raul; Iossifov, Ivan; Rzhetsky, Andrey

    2006-09-08

    Text-mining algorithms make mistakes in extracting facts from natural-language texts. In biomedical applications, which rely on use of text-mined data, it is critical to assess the quality (the probability that the message is correctly extracted) of individual facts--to resolve data conflicts and inconsistencies. Using a large set of almost 100,000 manually produced evaluations (most facts were independently reviewed more than once, producing independent evaluations), we implemented and tested a collection of algorithms that mimic human evaluation of facts provided by an automated information-extraction system. The performance of our best automated classifiers closely approached that of our human evaluators (ROC score close to 0.95). Our hypothesis is that, were we to use a larger number of human experts to evaluate any given sentence, we could implement an artificial-intelligence curator that would perform the classification job at least as accurately as an average individual human evaluator. We illustrated our analysis by visualizing the predicted accuracy of the text-mined relations involving the term cocaine.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Summary of GATEWAY report evaluating a trial installation of tunable-white LED lighting systems in three classrooms in the Carrollton-Farmers Branch Independent School District in Carrollton, TX. The report provides valuable insights into the use of this technology in a real-world setting.

  9. Enabling Handicapped Nonreaders to Independently Obtain Information: Initial Development of an Inexpensive Bar Code Reader System.

    ERIC Educational Resources Information Center

    VanBiervliet, Alan

    A project to develop and evaluate a bar code reader system as a self-directed information and instructional aid for handicapped nonreaders is described. The bar code technology involves passing a light sensitive pen or laser over a printed code with bars which correspond to coded numbers. A system would consist of a portable device which could…

  10. Security analysis of quadratic phase based cryptography

    NASA Astrophysics Data System (ADS)

    Muniraj, Inbarasan; Guo, Changliang; Malallah, Ra'ed; Healy, John J.; Sheridan, John T.

    2016-09-01

    The linear canonical transform (LCT) is essential in modeling a coherent light field propagation through first-order optical systems. Recently, a generic optical system, known as a Quadratic Phase Encoding System (QPES), for encrypting a two-dimensional (2D) image has been reported. It has been reported together with two phase keys the individual LCT parameters serve as keys of the cryptosystem. However, it is important that such the encryption systems also satisfies some dynamic security properties. Therefore, in this work, we examine some cryptographic evaluation methods, such as Avalanche Criterion and Bit Independence, which indicates the degree of security of the cryptographic algorithms on QPES. We compare our simulation results with the conventional Fourier and the Fresnel transform based DRPE systems. The results show that the LCT based DRPE has an excellent avalanche and bit independence characteristics than that of using the conventional Fourier and Fresnel based encryption systems.

  11. Analytical evaluation of ILM sensors, volume 1

    NASA Technical Reports Server (NTRS)

    Kirk, R. J.

    1975-01-01

    The functional requirements and operating environment constraints are defined for an independent landing monitor ILM which provides the flight crew with an independent assessment of the operation of the primary automatic landing system. The capabilities of radars, TV, forward looking infrared radiometers, multilateration, microwave radiometers, interferometers, and nuclear sensing concepts to meet the ILM conditions are analyzed. The most critical need for the ILM appears in the landing sequence from 1000 to 2000 meters from threshold through rollout. Of the sensing concepts analyzed, the following show potential of becoming feasible ILM's: redundant microwave landings systems, precision approach radar, airborne triangulation radar, multilateration with radar altimetry, and nuclear sensing.

  12. [Prognostic value of three different staging schemes based on pN, MLR and LODDS in patients with T3 esophageal cancer].

    PubMed

    Wang, L; Cai, L; Chen, Q; Jiang, Y H

    2017-10-23

    Objective: To evaluate the prognostic value of three different staging schemes based on positive lymph nodes (pN), metastatic lymph nodes ratio (MLR) and log odds of positive lymph nodes (LODDS) in patients with T3 esophageal cancer. Methods: From 2007 to 2014, clinicopathological characteristics of 905 patients who were pathologically diagnosed as T3 esophageal cancer and underwent radical esophagectomy in Zhejiang Cancer Hospital were retrospectively analyzed. Kaplan-Meier curves and Multivariate Cox proportional hazards models were used to evaluate the independent prognostic factors. The values of three lymph node staging schemes for predicting 5-year survival were analyzed by using receiver operating characteristic (ROC) curves. Results: The 1-, 3- and 5-year overall survival rates of patients with T3 esophageal cancer were 80.9%, 50.0% and 38.4%, respectively. Multivariate analysis showed that MLR stage, LODDS stage and differentiation were independent prognostic survival factors ( P <0.05 for all). ROC curves showed that the area under the curve of pN stage, MLR stage, LODDS stage was 0.607, 0.613 and 0.618, respectively. However, the differences were not statistically significant ( P >0.05). Conclusions: LODDS is an independent prognostic factor for patients with T3 esophageal cancer. The value of LODDS staging system may be superior to pN staging system for evaluating the prognosis of these patients.

  13. International Space Station (ISS) External Thermal Control System (ETCS) Loop A Pump Module (PM) Jettison Options Assessment

    NASA Technical Reports Server (NTRS)

    Murri, Daniel G.; Dwyer Cianciolo, Alicia; Shidner, Jeremy D.; Powell, Richard W.

    2014-01-01

    On December 11, 2013, the International Space Station (ISS) experienced a failure of the External Thermal Control System (ETCS) Loop A Pump Module (PM). To minimize the number of extravehicular activities (EVA) required to replace the PM, jettisoning the faulty pump was evaluated. The objective of this study was to independently evaluate the jettison options considered by the ISS Trajectory Operations Officer (TOPO) and to provide recommendations for safe jettison of the ETCS Loop A PM. The simulation selected to evaluate the TOPO options was the NASA Engineering and Safety Center's (NESC) version of Program to Optimize Simulated Trajectories II (POST2) developed to support another NESC assessment. The objective of the jettison analysis was twofold: (1) to independently verify TOPO posigrade and retrograde jettison results, and (2) to determine jettison guidelines based on additional sensitivity, trade study, and Monte Carlo (MC) analysis that would prevent PM recontact. Recontact in this study designates a propagated PM trajectory that comes within 500 m of the ISS propagated trajectory. An additional simulation using Systems Tool Kit (STK) was run for independent verification of the POST2 simulation results. Ultimately, the ISS Program removed the PM jettison option from consideration. However, prior to the Program decision, the retrograde jettison option remained part of the EVA contingency plan. The jettison analysis presented showed that, in addition to separation velocity/direction and the atmosphere conditions, the key variables in determining the time to recontact the ISS is highly dependent on the ballistic number (BN) difference between the object being jettisoned and the ISS.

  14. Evaluation of the Navys Sea/Shore Flow Policy

    DTIC Science & Technology

    2016-06-01

    CNA developed an independent Discrete -Event Simulation model to evaluate and assess the effect of alternative sea/shore flow policies. In this study...remains, even if the system is optimized. In building a Discrete -Event Simulation model, we discovered key factors that should be included in the... Discrete -Event Simulation model to evaluate the impact of sea/shore flow policy (the DES-SSF model) and compared the results with the SSFM for one

  15. A Trunk Support System to Identify Posture Control Mechanisms in Populations Lacking Independent Sitting

    PubMed Central

    Goodworth, Adam D.; Wu, Yen-Hsun; Felmlee, Duffy; Dunklebarger, Ellis; Saavedra, Sandra

    2016-01-01

    Populations with moderate-to-severe motor control impairments often exhibit degraded trunk control and/or lack the ability to sit unassisted. These populations need more research, yet their underdeveloped trunk control complicates identification of neural mechanisms behind their movements. The purpose of this study was to overcome this barrier by developing the first multi-articulated trunk support system to identify visual, vestibular, and proprioception contributions to posture in populations lacking independent sitting. The system provided external stability at a user-specific level on the trunk, so that body segments above the level of support required active posture control. The system included a tilting surface (controlled via servomotor) as a stimulus to investigate sensory contributions to postural responses. Frequency response and coherence functions between the surface tilt and trunk support were used to characterize system dynamics and indicated that surface tilts were accurately transmitted up to 5Hz. Feasibility of collecting kinematic data in participants lacking independent sitting was demonstrated in two populations: two typically developing infants, ~2-8 months, in a longitudinal study (8 sessions each) and four children with moderate-to-severe cerebral palsy (GMFCS III-V). Adaptability in the system was assessed by testing 16 adults (ages 18-63). Kinematic responses to continuous pseudorandom surface tilts were evaluated across 0.046–2Hz and qualitative feedback indicated that the trunk support and stimulus were comfortable for all subjects. Concepts underlying the system enable both research for, and rehabilitation in, populations lacking independent sitting. PMID:27046877

  16. Automated Simulation For Analysis And Design

    NASA Technical Reports Server (NTRS)

    Cantwell, E.; Shenk, Tim; Robinson, Peter; Upadhye, R.

    1992-01-01

    Design Assistant Workstation (DAWN) software being developed to facilitate simulation of qualitative and quantitative aspects of behavior of life-support system in spacecraft, chemical-processing plant, heating and cooling system of large building, or any of variety of systems including interacting process streams and processes. Used to analyze alternative design scenarios or specific designs of such systems. Expert system will automate part of design analysis: reason independently by simulating design scenarios and return to designer with overall evaluations and recommendations.

  17. A Detailed Evaluation of a Laser Triangulation Ranging System for Mobile Robots

    DTIC Science & Technology

    1983-08-01

    System Accuracy Factors ..................10 2.1.2 Detector "Cone of Vision" Problem ..................... 10 2. 1.3 Laser Triangulation Justification... product of these advances. Since 1968, when the effort began under a NASA grant, the project has undergone many changes both in the design goals and in...MD Vision System Accuracy Factors The accuracy of the data obtained by triangulation system depends on essentially three independent factors . They

  18. Development of a monitoring system for physical frailty in independent elderly.

    PubMed

    Hewson, David J; Jaber, Rana; Chkeir, Aly; Hammoud, Ali; Gupta, Dhruv; Bassement, Jennifer; Vermeulen, Joan; Yadav, Sandeep; de Witte, Luc; Duchene, Jacques

    2013-01-01

    Frailty is of increasing concern due to the associated decrease in independence of elderly who suffer from the condition. An innovative system was designed in order to objectively quantify the level of frailty based on a series of remote tests, each of which used objects similar to those found in peoples' homes. A modified ball, known as the Grip-ball was used to evaluate maximal grip force and exhaustion during an entirely remote assessment. A smartphone equipped with a tri-axial accelerometer was used to estimate gait velocity and physical activity level. Finally, a bathroom scale was used to assess involuntary weight loss. The smart phone processes all of the data generated, before it is transferred to a remote server where the user, their entourage, and any medical professionals with authorization can access the data. This innovative system could enable the onset of frailty to be detected early, thus giving sufficient time for a targeted intervention program to be implemented, thereby increasing independence for elderly users.

  19. Independent Orbiter Assessment (IOA): Analysis of the active thermal control subsystem

    NASA Technical Reports Server (NTRS)

    Sinclair, S. K.; Parkman, W. E.

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical (PCIs) items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results corresponding to the Orbiter Active Thermal Control Subsystem (ATCS) are documented. The major purpose of the ATCS is to remove the heat, generated during normal Shuttle operations from the Orbiter systems and subsystems. The four major components of the ATCS contributing to the heat removal are: Freon Coolant Loops; Radiator and Flow Control Assembly; Flash Evaporator System; and Ammonia Boiler System. In order to perform the analysis, the IOA process utilized available ATCS hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 310 failure modes analyzed, 101 were determined to be PCIs.

  20. Independent Orbiter Assessment (IOA): Analysis of the nose wheel steering subsystem

    NASA Technical Reports Server (NTRS)

    Mediavilla, Anthony Scott

    1986-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results for the Orbiter Nose Wheel Steering (NWS) hardware are documented. The NWS hardware provides primary directional control for the Orbiter vehicle during landing rollout. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. The original NWS design was envisioned as a backup system to differential braking for directional control of the Orbiter during landing rollout. No real effort was made to design the NWS system as fail operational. The brakes have much redundancy built into their design but the poor brake/tire performance has forced the NSTS to upgrade NWS to the primary mode of directional control during rollout. As a result, a large percentage of the NWS system components have become Potential Critical Items (PCI).

  1. Advanced life support systems in lunar and Martian environments utilizing a higher plant based engineering paradigm

    NASA Technical Reports Server (NTRS)

    Chamberland, Dennis

    1992-01-01

    The paper describes a higher-plant-based engineering paradigm for advanced life support in a Controlled Ecological Life Support System (CELSS) on the surface of the moon or Mars, called the CELSS Breadboard Project, designed at John F. Kennedy Space Center. Such a higher-plant-based system would use the plants for a direct food source, gas exchange, water reclamation, and plant residuals in a complex biological resource recovery scheme. The CELSS Breadboard Project utilizes a 'breadboard' approach of developing independent systems that are evaluated autonomously and are later interconnected. Such a scheme will enable evaluation of life support system methodologies tested for their efficiency in a life support system for habitats on the moon or Mars.

  2. Standardization of End-to-End Performance of Digital Video Teleconferencing/Video Telephony Systems

    DTIC Science & Technology

    1991-12-01

    SYSTEM 3-1 end-to-end video transmission system including both firmly specified and peripheral flexible functions. The format converter changes either...which manifests itself in both subjective evaluations and objective tests. The relative importance of performance parameters is likely to change with...conventional analog performance parameters to be largely independent of bit rate, and only slightly changed between different codec models. The

  3. System Simulation by Recursive Feedback: Coupling a Set of Stand-Alone Subsystem Simulations

    NASA Technical Reports Server (NTRS)

    Nixon, D. D.

    2001-01-01

    Conventional construction of digital dynamic system simulations often involves collecting differential equations that model each subsystem, arran g them to a standard form, and obtaining their numerical gin solution as a single coupled, total-system simultaneous set. Simulation by numerical coupling of independent stand-alone subsimulations is a fundamentally different approach that is attractive because, among other things, the architecture naturally facilitates high fidelity, broad scope, and discipline independence. Recursive feedback is defined and discussed as a candidate approach to multidiscipline dynamic system simulation by numerical coupling of self-contained, single-discipline subsystem simulations. A satellite motion example containing three subsystems (orbit dynamics, attitude dynamics, and aerodynamics) has been defined and constructed using this approach. Conventional solution methods are used in the subsystem simulations. Distributed and centralized implementations of coupling have been considered. Numerical results are evaluated by direct comparison with a standard total-system, simultaneous-solution approach.

  4. Nanowire systems: technology and design

    PubMed Central

    Gaillardon, Pierre-Emmanuel; Amarù, Luca Gaetano; Bobba, Shashikanth; De Marchi, Michele; Sacchetto, Davide; De Micheli, Giovanni

    2014-01-01

    Nanosystems are large-scale integrated systems exploiting nanoelectronic devices. In this study, we consider double independent gate, vertically stacked nanowire field effect transistors (FETs) with gate-all-around structures and typical diameter of 20 nm. These devices, which we have successfully fabricated and evaluated, control the ambipolar behaviour of the nanostructure by selectively enabling one type of carriers. These transistors work as switches with electrically programmable polarity and thus realize an exclusive or operation. The intrinsic higher expressive power of these FETs, when compared with standard complementary metal oxide semiconductor technology, enables us to realize more efficient logic gates, which we organize as tiles to realize nanowire systems by regular arrays. This article surveys both the technology for double independent gate FETs as well as physical and logic design tools to realize digital systems with this fabrication technology. PMID:24567471

  5. Contracting for Independent Evaluation: Approaches to an Inherent Tension

    ERIC Educational Resources Information Center

    Klerman, Jacob Alex

    2010-01-01

    There has recently been discussion of whether independent contract evaluation is possible. This article acknowledges the inherent tension in contract evaluation and in response suggests a range of constructive approaches to improving the independence of contract evaluation. In particular, a clear separation between the official evaluation report…

  6. Evaluation of an Assistive Telepresence Robot for Elderly Healthcare.

    PubMed

    Koceski, Saso; Koceska, Natasa

    2016-05-01

    In this paper we described the telepresence robot system designed to improve the well-being of elderly by supporting them to do daily activities independently, to facilitate social interaction in order to overcome a sense of social isolation and loneliness as well as to support the professional caregivers in everyday care. In order to investigate the acceptance of the developed robot system, evaluation study involved elderly people and professional caregivers, as two potential user groups was conducted. The results of this study are also presented and discussed.

  7. NHS Blood Tracking Pilot: City University Evaluation Project

    NASA Astrophysics Data System (ADS)

    Goddard, Kate; Shabestari, Omid; Adriano, Juan; Kay, Jonathan; Roudsari, Abdul

    Automation of healthcare processes is an emergent theme in the drive to increase patient safety. The Mayday Hospital has been chosen as the pilot site for the implementation of the Electronic Clinical Transfusion Management System to track blood from the point of ordering to the final transfusion. The Centre for Health Informatics at City University is carrying out an independent evaluation of the system implementation using a variety of methodologies to both formatively inform the implementation process and summatively provide an account of the lessons learned for future implementations.

  8. NASA Non-Flow-Through PEM Fuel Cell System for Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Araghi, Koorosh R.

    2011-01-01

    NASA is researching passive NFT Proton Exchange Membrane (PEM) fuel cell technologies for primary fuel cell power plants in air-independent applications. NFT fuel cell power systems have a higher power density than flow through systems due to both reduced parasitic loads and lower system mass and volume. Reactant storage still dominates system mass/volume considerations. NFT fuel cell stack testing has demonstrated equivalent short term performance to flow through stacks. More testing is required to evaluate long-term performance.

  9. Using an adapted form of the picture exchange communication system to increase independent requesting in deafblind adults with learning disabilities.

    PubMed

    Bracken, Maeve; Rohrer, Nicole

    2014-02-01

    The current study assessed the effectiveness of an adapted form of the Picture Exchange Communication System (PECS) in increasing independent requesting in deafblind adults with learning disabilities. PECS cards were created to accommodate individual needs, including adaptations such as enlarging photographs and using swelled images which consisted of images created on raised line drawing paper. Training included up to Phase III of PECS and procedures ensuring generalizations across individuals and contexts were included. The effects of the intervention were evaluated using a multiple baseline design across participants. Results demonstrated an increase in independent requesting with each of the participants reaching mastery criterion. These results suggest that PECS, in combination with some minor adaptations, may be an effective communicative alternative for individuals who are deafblind and have learning impairments. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Fuzzy AHP Analysis on Enterprises’ Independent Innovation Capability Evaluation

    NASA Astrophysics Data System (ADS)

    Zhu, Yu; Lei, Huai-ying

    Independent innovation has become a key factor in the rapid and healthy development of the enterprises. Therefore, an effective and reasonable comprehensive evaluation on the independent innovation capability of the businesses is especially important. This paper applies fuzzy AHP in the evaluation of the independent innovation capability of the businesses, and validates the rationality and feasibility of the evaluation methods and the indicators.

  11. [Cooling shell in renal transplantation. Thermometric evaluation of a prototype].

    PubMed

    Desgrandchamps, F; Eugene, M; Tuchschmid, Y; Muller, F; Teillac, P; Idatte, J M; Le Duc, A

    1996-02-01

    We have developed a cooling system for renal transplants designed to eliminate the second period of warm ischaemia corresponding to the vascular anastomosis phase of renal transplantation. This is an autonomous and independent system which forms a shell around the transplant. Following application of the system, cooling is achieved by refrigeration of a Multitherm sponge contained in the wall of the shell. The thermometric characteristics of a prototype were evaluated in vitro and in vivo in pigs. This system allows the kidney to be preserved at a temperature of less than 10 degrees C for 1 hour without inducing any risk of lesions of the renal surface. Human applications should be developed in the near future.

  12. Evaluating a GPS-Based Transportation Device to Support Independent Bus Travel by People with Intellectual Disability

    ERIC Educational Resources Information Center

    Davies, Daniel K.; Stock, Steven E.; Holloway, Shane; Wehmeyer, Michael L.

    2010-01-01

    We examined the utility of a PDA-based software system with integrated GPS technology for providing location-aware visual and auditory prompts to enable people with intellectual disability to successfully navigate a downtown bus route. Participants using the system were significantly more successful at completing a bus route than were people in a…

  13. An Evaluation of Independent Learning of the Japanese Hiragana System Using an Interactive CD

    ERIC Educational Resources Information Center

    Geraghty, Barbara; Quinn, Ann Marcus

    2009-01-01

    As Japanese uses three writing systems (hiragana, katakana, and the ideograms known as kanji), and as materials in the target language include all three, it is a major challenge to learn to read and write quickly. This paper focuses on interactive multi-media methods of teaching Japanese reading which foster learner autonomy. As little has been…

  14. Appraising the value of independent EIA follow-up verifiers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wessels, Jan-Albert, E-mail: janalbert.wessels@nwu.ac.za; Retief, Francois, E-mail: francois.retief@nwu.ac.za; Morrison-Saunders, Angus, E-mail: A.Morrison-Saunders@murdoch.edu.au

    Independent Environmental Impact Assessment (EIA) follow-up verifiers such as monitoring agencies, checkers, supervisors and control officers are active on various construction sites across the world. There are, however, differing views on the value that these verifiers add and very limited learning in EIA has been drawn from independent verifiers. This paper aims to appraise how and to what extent independent EIA follow-up verifiers add value in major construction projects in the developing country context of South Africa. A framework for appraising the role of independent verifiers was established and four South African case studies were examined through a mixture ofmore » site visits, project document analysis, and interviews. Appraisal results were documented in the performance areas of: planning, doing, checking, acting, public participating and integration with other programs. The results indicate that independent verifiers add most value to major construction projects when involved with screening EIA requirements of new projects, allocation of financial and human resources, checking legal compliance, influencing implementation, reporting conformance results, community and stakeholder engagement, integration with self-responsibility programs such as environmental management systems (EMS), and controlling records. It was apparent that verifiers could be more creatively utilized in pre-construction preparation, providing feedback of knowledge into assessment of new projects, giving input to the planning and design phase of projects, and performance evaluation. The study confirms the benefits of proponent and regulator follow-up, specifically in having independent verifiers that disclose information, facilitate discussion among stakeholders, are adaptable and proactive, aid in the integration of EIA with other programs, and instill trust in EIA enforcement by conformance evaluation. Overall, the study provides insight on how to harness the learning opportunities arising from EIA follow-up through the appointment of independent verifiers. - Highlights: • A framework for appraising the role of independent verifiers is established. • The value added to EIA follow-up by independent verifiers in South Africa is documented. • Verifiers add most value when involved with screening, checking compliance, influencing decisions and community engagement. • Verifiers could be more creatively utilized in pre-construction preparation, giving feedback, and performance evaluation.« less

  15. ESEA Title I Migrant. Final Technical Report.

    ERIC Educational Resources Information Center

    Austin Independent School District, TX. Office of Research and Evaluation.

    The 1981-82 Austin (Texas) Independent School District Title I Migrant Program consisted of seven components: three instructional components--prekindergarten, communication skills, and summer school; and four support components--health services, parental involvement, migrant student record transfer system (MSRTS), and evaluation. The major…

  16. Compressive Sensing for DoD Sensor Systems

    DTIC Science & Technology

    2012-11-01

    Schmidt (1963) [45] indicated a cosmologically distant, extremely luminous object, the first example of a quasar - an accretion-powered black hole at...evaluating cosmological models and for determining key cos- mological parameters. Sparsity up to the m-degeneracy is independent of the choice of

  17. Final Report: Independent Design Review, Celanese Fiber Operations Superfund Site, Shelby, North Carolina, EPA Region 4

    EPA Pesticide Factsheets

    The Celanese site is located in Shelby, North Carolina. Operation of the P&T system was discontinued on a trial basis for two years to evaluate monitored natural attenuation as a potential ground water remedy.

  18. The engineering design integration (EDIN) system. [digital computer program complex

    NASA Technical Reports Server (NTRS)

    Glatt, C. R.; Hirsch, G. N.; Alford, G. E.; Colquitt, W. N.; Reiners, S. J.

    1974-01-01

    A digital computer program complex for the evaluation of aerospace vehicle preliminary designs is described. The system consists of a Univac 1100 series computer and peripherals using the Exec 8 operating system, a set of demand access terminals of the alphanumeric and graphics types, and a library of independent computer programs. Modification of the partial run streams, data base maintenance and construction, and control of program sequencing are provided by a data manipulation program called the DLG processor. The executive control of library program execution is performed by the Univac Exec 8 operating system through a user established run stream. A combination of demand and batch operations is employed in the evaluation of preliminary designs. Applications accomplished with the EDIN system are described.

  19. Seeing the System through the End Users' Eyes: Shadow Expert Technique for Evaluating the Consistency of a Learning Management System

    NASA Astrophysics Data System (ADS)

    Holzinger, Andreas; Stickel, Christian; Fassold, Markus; Ebner, Martin

    Interface consistency is an important basic concept in web design and has an effect on performance and satisfaction of end users. Consistency also has significant effects on the learning performance of both expert and novice end users. Consequently, the evaluation of consistency within a e-learning system and the ensuing eradication of irritating discrepancies in the user interface redesign is a big issue. In this paper, we report of our experiences with the Shadow Expert Technique (SET) during the evaluation of the consistency of the user interface of a large university learning management system. The main objective of this new usability evaluation method is to understand the interaction processes of end users with a specific system interface. Two teams of usability experts worked independently from each other in order to maximize the objectivity of the results. The outcome of this SET method is a list of recommended changes to improve the user interaction processes, hence to facilitate high consistency.

  20. A Reference Architecture for Space Information Management

    NASA Technical Reports Server (NTRS)

    Mattmann, Chris A.; Crichton, Daniel J.; Hughes, J. Steven; Ramirez, Paul M.; Berrios, Daniel C.

    2006-01-01

    We describe a reference architecture for space information management systems that elegantly overcomes the rigid design of common information systems in many domains. The reference architecture consists of a set of flexible, reusable, independent models and software components that function in unison, but remain separately managed entities. The main guiding principle of the reference architecture is to separate the various models of information (e.g., data, metadata, etc.) from implemented system code, allowing each to evolve independently. System modularity, systems interoperability, and dynamic evolution of information system components are the primary benefits of the design of the architecture. The architecture requires the use of information models that are substantially more advanced than those used by the vast majority of information systems. These models are more expressive and can be more easily modularized, distributed and maintained than simpler models e.g., configuration files and data dictionaries. Our current work focuses on formalizing the architecture within a CCSDS Green Book and evaluating the architecture within the context of the C3I initiative.

  1. Tumor-infiltrating Neutrophils is Prognostic and Predictive for Postoperative Adjuvant Chemotherapy Benefit in Patients With Gastric Cancer.

    PubMed

    Zhang, Heng; Liu, Hao; Shen, Zhenbin; Lin, Chao; Wang, Xuefei; Qin, Jing; Qin, Xinyu; Xu, Jiejie; Sun, Yihong

    2018-02-01

    This study was aimed to investigate the prognostic value of tumor-infiltrating neutrophils (TINs) and to generate a predictive model to refine postoperative risk stratification system for patients with gastric cancer. TIN presents in various malignant tumors, but its clinical significance in gastric cancer remains obscure. The study enrolled 3 independent sets of patients with gastric cancer from 2 institutional medical centers of China. TIN was estimated by immunohistochemical staining of CD66b, and its relationship with clinicopathological features and clinical outcomes were evaluated. Prognostic accuracies were evaluated by C-index and Akaike information criterion. TINs in gastric cancer tissues ranged from 0 to 192 cells/high magnification filed (HPF), 0 to 117 cells/HPF, and 0 to 142 cells/HPF in the training, testing, and validation sets, respectively. TINs were negatively correlated with lymph node classification (P = 0.007, P = 0.041, and P = 0.032, respectively) and tumor stage (P = 0.019, P = 0.013, and P = 0.025, respectively) in the 3 sets. Moreover, multivariate analysis identified TINs and tumor node metastasis (TNM) stage as 2 independent prognostic factors for overall survival. Incorporation of TINs into well-established TNM system generated a predictive model that shows better predictive accuracy for overall survival. More importantly, patients with higher TINs were prone to overall survival benefit from postoperative adjuvant chemotherapy. These results were validated in the independent testing and validation sets. TIN in gastric cancer was identified as an independent prognostic factor, which could be incorporated into standard TNM staging system to refine risk stratification and predict for overall survival benefit from postoperative chemotherapy in patients with gastric cancer.

  2. Independent Verification and Validation of Complex User Interfaces: A Human Factors Approach

    NASA Technical Reports Server (NTRS)

    Whitmore, Mihriban; Berman, Andrea; Chmielewski, Cynthia

    1996-01-01

    The Usability Testing and Analysis Facility (UTAF) at the NASA Johnson Space Center has identified and evaluated a potential automated software interface inspection tool capable of assessing the degree to which space-related critical and high-risk software system user interfaces meet objective human factors standards across each NASA program and project. Testing consisted of two distinct phases. Phase 1 compared analysis times and similarity of results for the automated tool and for human-computer interface (HCI) experts. In Phase 2, HCI experts critiqued the prototype tool's user interface. Based on this evaluation, it appears that a more fully developed version of the tool will be a promising complement to a human factors-oriented independent verification and validation (IV&V) process.

  3. [Quality assurance in coding expertise of hospital cases in the German DRG system. Evaluation of inter-rater reliability in MDK expertise].

    PubMed

    Huber, H; Brambrink, M; Funk, R; Rieger, M

    2012-10-01

    The purpose of this study was to evaluate differences in the D-DRG results of a hospital case by 2 independently coding MKD raters. Calculation of the 2-inter-rater reliability was performed by examination of the coding of individual hospital cases. The reasons for the non-agreement of the expert evaluations and suggestions to improve the process are discussed. From the expert evaluation pool of the MDK-WL a random sample of 0.7% of the 57,375 expertises was taken. Distribution equality with the basic total was tested by the χ² test or, respectively, Fisher's exact test. For the total of 402 individual hospital cases, the G-DRG case sums of 2 experts of the MDK were determined independently and the results checked for each individual case for agreement or non-agreement. The corresponding confidence intervals with standard errors were analysed to test if certain major diagnosis categories (MDC) were statistically significantly more affected by differing expertise results than others. In 280 of the total 402 tested hospital cases, the 2 MDK raters independently reached the same G-DRG results; in 122 cases the G-DRG case sums determined by the 2 raters differed (agreement 70%; CI 65.2-74.1). Different DRG results between the 2 experts occurred regularly in the entire MDC spectrum. No MDC chapter in which significant differences between the 2 raters arose could be identified. The results of our study demonstrate an almost 70% agreement in the evaluation of hospital cost accounts by 2 independently operating MDK. This result leaves room for improvement. Optimisation potentials can be recognised on the basis of the results. Potential for improvement was established in combination with regular further training and the expansion of binding internal code recommendations as well as exchange of code-relevant information among experts in internal forums. The presented model is in principle suitable for cross-border examinations within the MDK system with the advantage that further trends could be uncovered by more variety and larger numbers of the randomly selected cases. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Analytical evaluation of ILM sensors. Volume 2: Appendices

    NASA Technical Reports Server (NTRS)

    Kirk, R. J.

    1975-01-01

    The applicability of various sensing concepts to independent landing monitor systems was analyzed. Microwave landing system MLS accuracy requirements are presented along with a description of MLS airborne equipment. Computer programs developed during the analysis are described and include: a mathematical computer model for use in the performance assessment of reconnaissance sensor systems; a theoretical formulation of electromagnetic scattering to generate data at high incidence angles; atmospheric attenuation of microwaves; and microwave radiometry, programs

  5. A medical/vocational case coordination system for persons with brain injury: an evaluation of employment outcomes.

    PubMed

    Malec, J F; Buffington, A L; Moessner, A M; Degiorgio, L

    2000-08-01

    To evaluate initial placement and 1-year employment outcomes of a Medical/Vocational Case Coordination System (MVCCS) for persons with brain injury (BI) that provides: (1) early case identification and coordination, (2) appropriate medical and vocational rehabilitation interventions, (3) work trials, and (4) supported employment interventions including job coaching. One hundred fourteen Minnesota residents, ages 18 to 65 years, with acquired BI. Five levels of Vocational Independence Scale (VIS). Preinjury employment status (VIS) and years of education, severity of initial injury, time since injury, current impairment/disability as measured by the Rasch-analyzed Staff Mayo-Portland Adaptability Inventory (MPAI), and impaired self-awareness measured by staff rating and the difference between Staff MPAI and Survivor MPAI. At placement, 46% in independent work; 25% in transitional placements; 9% in long-term supported employment; 10% in sheltered work; and 10% not placed. At 1-year follow-up (n = 101), 53% in independent work; 19% in transitional placement; 9% in supported work; 6% in sheltered work; and 13% unemployed. Regression analyses showed time since injury and Rasch Staff MPAI predicted VIS at placement; only VIS at placement independently predicted VIS at 1-year follow-up; Rasch Staff MPAI and preinjury education level predicted time to placement. The MVCCS optimized vocational outcome after BI. Time since injury and impairment/disability best predicted vocational placement. Level of initial placement best predicted employment status at follow-up. Persons with greater disability required more extended time and more extensive rehabilitation services before placement.

  6. Design and Evaluation of Hydrophilic Matrix System for pH-Independent Sustained Release of Weakly Acidic Poorly Soluble Drug.

    PubMed

    Huang, Jinheng; Lin, Huaqing; Peng, Bingxin; Huang, Qianfeng; Shuai, Fangzhou; Xie, Yanxian

    2018-04-30

    The aim of this research was to design and evaluate a hydrophilic matrix system for sustained release of glipizide, a weakly acidic poor soluble drug. A combination of inclusion complexation and microenvironmental pH modification techniques was utilized to improve the dissolution and pH-independent release of glipizide. Hydroxypropyl-β-cyclodextrin (HP-β-CD) was used as the complexation agent while sodium citrate and magnesium oxide (MgO) were used as model pH modifiers. The hydrophilic matrix tablets were prepared by powder direct compression and evaluated by in vitro dissolution study respectively in pH 6.8 and pH 1.2 dissolution media. The formulations containing MgO exhibited increased cumulative drug release from less than 40% in the reference formulation to 90% within 24 h in acidic media (pH 1.2). The release profile in acidic media was similar to the alkaline media (pH 6.8) with a similarity factor (f 2 ) of 55.0, suggesting the weakening of the effect of pH on the dissolution efficiency of glipizide. The release profile fitted well into the Higuchi model and the dominant mechanism of drug release was Fickian diffusion while case II transport/polymer relaxation occurred. In conclusion, combining inclusion complexation agents and pH modifiers had improved the dissolution of glipizide as well as achieved the pH-independent release profile.

  7. Evaluation of an airborne triple-pulsed 2 μm IPDA lidar for simultaneous and independent atmospheric water vapor and carbon dioxide measurements.

    PubMed

    Refaat, Tamer F; Singh, Upendra N; Yu, Jirong; Petros, Mulugeta; Ismail, Syed; Kavaya, Michael J; Davis, Kenneth J

    2015-02-20

    Water vapor and carbon dioxide are the most dominant greenhouse gases directly contributing to the Earth's radiation budget and global warming. A performance evaluation of an airborne triple-pulsed integrated path differential absorption (IPDA) lidar system for simultaneous and independent monitoring of atmospheric water vapor and carbon dioxide column amounts is presented. This system leverages a state-of-the-art Ho:Tm:YLF triple-pulse laser transmitter operating at 2.05 μm wavelength. The transmitter provides wavelength tuning and locking capabilities for each pulse. The IPDA lidar system leverages a low risk and technologically mature receiver system based on InGaAs pin detectors. Measurement methodology and wavelength setting are discussed. The IPDA lidar return signals and error budget are analyzed for airborne operation on-board the NASA B-200. Results indicate that the IPDA lidar system is capable of measuring water vapor and carbon dioxide differential optical depth with 0.5% and 0.2% accuracy, respectively, from an altitude of 8 km to the surface and with 10 s averaging. Provided availability of meteorological data, in terms of temperature, pressure, and relative humidity vertical profiles, the differential optical depth conversion into weighted-average column dry-air volume-mixing ratio is also presented.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oyunbaatar, Nomin-Erdene; Choi, Young Soo; Lee, Dong-Weon, E-mail: mems@jnu.ac.kr

    This paper describes a self-adjustable four-point probe (S4PP) system with a square configuration. The S4PP system consists of 3D polymer coil springs for the independent operation of each tungsten (W) probe, microfluidic channels filled with a nontoxic liquid metal, and a LabView-based control system. The 3D coil springs made by PMMA are fabricated with a 3D printer and are positioned in a small container filled with the non-toxic liquid metal. This unique configuration allows independent self-adjustment of the probe heights for precise measurements of the electrical properties of both flexible and large-step-height microsamples. The feasibility of the fabricated S4PP systemmore » is evaluated by measuring the specific resistance of Cr and Au thin films deposited on silicon wafers. The system is then employed to evaluate the electrical properties of a Au thin film deposited onto a flexible and easily breakable silicon diaphragm (spring constant: ∼3.6 × 10{sup −5} N/m). The resistance of the Cr thin films (thickness: 450 nm) with step heights of 60 and 90 μm is also successfully characterized. These experimental results indicate that the proposed S4PP system can be applied to common metals and semiconductors as well as flexible and large-step-height samples.« less

  9. Automated Detection of Glaucoma From Topographic Features of the Optic Nerve Head in Color Fundus Photographs.

    PubMed

    Chakrabarty, Lipi; Joshi, Gopal Datt; Chakravarty, Arunava; Raman, Ganesh V; Krishnadas, S R; Sivaswamy, Jayanthi

    2016-07-01

    To describe and evaluate the performance of an automated CAD system for detection of glaucoma from color fundus photographs. Color fundus photographs of 2252 eyes from 1126 subjects were collected from 2 centers: Aravind Eye Hospital, Madurai and Coimbatore, India. The images of 1926 eyes (963 subjects) were used to train an automated image analysis-based system, which was developed to provide a decision on a given fundus image. A total of 163 subjects were clinically examined by 2 ophthalmologists independently and their diagnostic decisions were recorded. The consensus decision was defined to be the clinical reference (gold standard). Fundus images of eyes with disagreement in diagnosis were excluded from the study. The fundus images of the remaining 314 eyes (157 subjects) were presented to 4 graders and their diagnostic decisions on the same were collected. The performance of the system was evaluated on the 314 images, using the reference standard. The sensitivity and specificity of the system and 4 independent graders were determined against the clinical reference standard. The system achieved an area under receiver operating characteristic curve of 0.792 with a sensitivity of 0.716 and specificity of 0.717 at a selected threshold for the detection of glaucoma. The agreement with the clinical reference standard as determined by Cohen κ is 0.45 for the proposed system. This is comparable to that of the image-based decisions of 4 ophthalmologists. An automated system was presented for glaucoma detection from color fundus photographs. The overall evaluation results indicated that the presented system was comparable in performance to glaucoma classification by a manual grader solely based on fundus image examination.

  10. 7 CFR 1730.24 - RUS review and evaluation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... independent summary of the operations and maintenance practices of the borrower. The borrower's management... and maintenance practices of each borrower for the purpose of assessing loan security and determining..., and records related to the operations and maintenance of its complete system. Reports made by other...

  11. MorphoSaurus--design and evaluation of an interlingua-based, cross-language document retrieval engine for the medical domain.

    PubMed

    Markó, K; Schulz, S; Hahn, U

    2005-01-01

    We propose an interlingua-based indexing approach to account for the particular challenges that arise in the design and implementation of cross-language document retrieval systems for the medical domain. Documents, as well as queries, are mapped to a language-independent conceptual layer on which retrieval operations are performed. We contrast this approach with the direct translation of German queries to English ones which, subsequently, are matched against English documents. We evaluate both approaches, interlingua-based and direct translation, on a large medical document collection, the OHSUMED corpus. A substantial benefit for interlingua-based document retrieval using German queries on English texts is found, which amounts to 93% of the (monolingual) English baseline. Most state-of-the-art cross-language information retrieval systems translate user queries to the language(s) of the target documents. In contra-distinction to this approach, translating both documents and user queries into a language-independent, concept-like representation format is more beneficial to enhance cross-language retrieval performance.

  12. Breast Cancer Detection with Reduced Feature Set.

    PubMed

    Mert, Ahmet; Kılıç, Niyazi; Bilgili, Erdem; Akan, Aydin

    2015-01-01

    This paper explores feature reduction properties of independent component analysis (ICA) on breast cancer decision support system. Wisconsin diagnostic breast cancer (WDBC) dataset is reduced to one-dimensional feature vector computing an independent component (IC). The original data with 30 features and reduced one feature (IC) are used to evaluate diagnostic accuracy of the classifiers such as k-nearest neighbor (k-NN), artificial neural network (ANN), radial basis function neural network (RBFNN), and support vector machine (SVM). The comparison of the proposed classification using the IC with original feature set is also tested on different validation (5/10-fold cross-validations) and partitioning (20%-40%) methods. These classifiers are evaluated how to effectively categorize tumors as benign and malignant in terms of specificity, sensitivity, accuracy, F-score, Youden's index, discriminant power, and the receiver operating characteristic (ROC) curve with its criterion values including area under curve (AUC) and 95% confidential interval (CI). This represents an improvement in diagnostic decision support system, while reducing computational complexity.

  13. High accuracy LADAR scene projector calibration sensor development

    NASA Astrophysics Data System (ADS)

    Kim, Hajin J.; Cornell, Michael C.; Naumann, Charles B.; Bowden, Mark H.

    2008-04-01

    A sensor system for the characterization of infrared laser radar scene projectors has been developed. Available sensor systems do not provide sufficient range resolution to evaluate the high precision LADAR projector systems developed by the U.S. Army Research, Development and Engineering Command (RDECOM) Aviation and Missile Research, Development and Engineering Center (AMRDEC). With timing precision capability to a fraction of a nanosecond, it can confirm the accuracy of simulated return pulses from a nominal range of up to 6.5 km to a resolution of 4cm. Increased range can be achieved through firmware reconfiguration. Two independent amplitude triggers measure both rise and fall time providing a judgment of pulse shape and allowing estimation of the contained energy. Each return channel can measure up to 32 returns per trigger characterizing each return pulse independently. Currently efforts include extending the capability to 8 channels. This paper outlines the development, testing, capabilities and limitations of this new sensor system.

  14. Bilingual Education in Brunei: The Evolution of the Brunei Approach to Bilingual Education and the Role of CfBT in Promoting Educational Change. Research Briefing

    ERIC Educational Resources Information Center

    Riggall, Anna, Ed.

    2014-01-01

    During 2012/13 academics from the Department of Education, University of Oxford, were commissioned by CfBT to conduct an independent evaluation of the CfBT Brunei English teaching programme. The evaluation sought to document the various processes of change and improvement within the Bruneian education system between 1996 and 2012, in particular…

  15. Bilingual Education in Brunei: The Evolution of the Brunei Approach to Bilingual Education and the Role of CfBT in Promoting Educational Change. Summary Report

    ERIC Educational Resources Information Center

    Riggall, Anna, Ed.

    2014-01-01

    During 2012/13, academics from the Department of Education, University of Oxford were commissioned by CfBT to conduct an independent evaluation of the CfBT Brunei English teaching programme. The evaluation sought to document the various processes of change and improvement within the Bruneian education system between 1996 and 2012, in particular…

  16. Managing Multiple Sources of Information in an Independent K-12 Private School: A Case Study in a Student Information Systems Evaluation

    ERIC Educational Resources Information Center

    Yares, Ali Chava Kaufman

    2010-01-01

    Information is everywhere and finding the best method to manage it is a problem that all types of organizations have to deal with. Schools use Student Information Systems (SIS) to manage Student Data, Financial Information, Development, Human Resources, Admission, Financial Aid, Enrollment, Scheduling, and Health Information. A survey of 107…

  17. Independent evaluation: insights from public accounting.

    PubMed

    Brown, Abigail B; Klerman, Jacob Alex

    2012-06-01

    Maintaining the independence of contract government program evaluation presents significant contracting challenges. The ideal outcome for an agency is often both the impression of an independent evaluation and a glowing report. In this, independent evaluation is like financial statement audits: firm management wants both a public accounting firm to attest to the fairness of its financial accounts and to be allowed to account for transactions as it sees fit. In both cases, the evaluation or audit is being conducted on behalf of outsiders--the public or shareholders--but is overseen by a party with significant interests at stake in the outcome-the agency being evaluated or executive management of the firm. We review the contracting strategies developed to maintain independence in auditing. We examine evidence on the effectiveness of professionalism, reputation, liability and owner oversight in constraining behavior in auditing. We then establish parallels with contracting for evaluations and apply these insights to changes that might maintain and improve evaluator independence. By analogy with the Sarbanes Oxley Act of 2002 reforms in auditing, we recommend exploring using a reformulated Technical Working Group to encourage more prompt release of more evaluation results and to help insulate evaluators from inappropriate pressure to change their results or analysis approach.

  18. Evaluation of robot-assisted gait training using integrated biofeedback in neurologic disorders.

    PubMed

    Stoller, Oliver; Waser, Marco; Stammler, Lukas; Schuster, Corina

    2012-04-01

    Neurological disorders lead to walking disabilities, which are often treated using robot-assisted gait training (RAGT) devices such as the driven gait-orthosis Lokomat. A novel integrated biofeedback system was developed to facilitate therapeutically desirable activities during walking. The aim of this study was to evaluate the feasibility to detect changes during RAGT by using this novel biofeedback approach in a clinical setting for patients with central neurological disorders. 84 subjects (50 men and 34 women, mean age of 58 ± 13 years) were followed over 8 RAGT sessions. Outcome measures were biofeedback values as weighted averages of torques measured in the joint drives and independent parameters such as guidance force, walking speed, patient coefficient, session duration, time between sessions and total treatment time. Joint segmented analysis showed significant trends for decreasing hip flexion activity (p ≤.003) and increasing knee extension activity (p ≤.001) during RAGT sessions with an intercorrelation of r=-.43 (p ≤.001). Further associations among independent variables were not statistically significant. This is the first study that evaluates the Lokomat integrated biofeedback system in different neurological disorders in a clinical setting. Results suggest that this novel biofeedback approach used in this study is not able to detect progress during RAGT. These findings should be taken into account when refining existing or developing new biofeedback strategies in RAGT relating to appropriate systems to evaluate progress and support therapist feedback in clinical settings. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Maternal social support and neighborhood income inequality as predictors of low birth weight and preterm birth outcome disparities: analysis of South Carolina Pregnancy Risk Assessment and Monitoring System survey, 2000-2003.

    PubMed

    Nkansah-Amankra, Stephen; Dhawain, Ashish; Hussey, James Robert; Luchok, Kathryn J

    2010-09-01

    Effects of income inequality on health and other social systems have been a subject of considerable debate, but only a few studies have used multilevel models to evaluate these relationships. The main objectives of the study were to (1) Evaluate the relationships among neighborhood income inequality, social support and birth outcomes (low birth weight, and preterm delivery) and (2) Assess variations in racial disparities in birth outcomes across neighborhood contexts of income distribution and maternal social support. We evaluated these relationships by using South Carolina Pregnancy Risk Assessment and Monitoring System (PRAMS) survey for 2000-2003 geocoded to 2000 US Census data for South Carolina. Multilevel analysis was used to simultaneously evaluate the association between income inequality (measured as Gini), maternal social relationships and birth outcomes (low birth weight and preterm delivery). The results showed residence in neighborhoods with medium levels of income inequality was independently associated with low birth weight (OR: 2.00; 95% CI 1.14-3.26), but not preterm birth; low social support was an independent risk for low birth weight or preterm births. The evidence suggests that non-Hispanic black mothers were at increased risks of low birth weight or preterm birth primarily due to greater exposures of neighborhood deprivations associated with low income and reduced social support and modified by unequal income distribution.

  20. Development and reproducibility evaluation of a Monte Carlo-based standard LINAC model for quality assurance of multi-institutional clinical trials.

    PubMed

    Usmani, Muhammad Nauman; Takegawa, Hideki; Takashina, Masaaki; Numasaki, Hodaka; Suga, Masaki; Anetai, Yusuke; Kurosu, Keita; Koizumi, Masahiko; Teshima, Teruki

    2014-11-01

    Technical developments in radiotherapy (RT) have created a need for systematic quality assurance (QA) to ensure that clinical institutions deliver prescribed radiation doses consistent with the requirements of clinical protocols. For QA, an ideal dose verification system should be independent of the treatment-planning system (TPS). This paper describes the development and reproducibility evaluation of a Monte Carlo (MC)-based standard LINAC model as a preliminary requirement for independent verification of dose distributions. The BEAMnrc MC code is used for characterization of the 6-, 10- and 15-MV photon beams for a wide range of field sizes. The modeling of the LINAC head components is based on the specifications provided by the manufacturer. MC dose distributions are tuned to match Varian Golden Beam Data (GBD). For reproducibility evaluation, calculated beam data is compared with beam data measured at individual institutions. For all energies and field sizes, the MC and GBD agreed to within 1.0% for percentage depth doses (PDDs), 1.5% for beam profiles and 1.2% for total scatter factors (Scps.). Reproducibility evaluation showed that the maximum average local differences were 1.3% and 2.5% for PDDs and beam profiles, respectively. MC and institutions' mean Scps agreed to within 2.0%. An MC-based standard LINAC model developed to independently verify dose distributions for QA of multi-institutional clinical trials and routine clinical practice has proven to be highly accurate and reproducible and can thus help ensure that prescribed doses delivered are consistent with the requirements of clinical protocols. © The Author 2014. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  1. An experimental evaluation of software redundancy as a strategy for improving reliability

    NASA Technical Reports Server (NTRS)

    Eckhardt, Dave E., Jr.; Caglayan, Alper K.; Knight, John C.; Lee, Larry D.; Mcallister, David F.; Vouk, Mladen A.; Kelly, John P. J.

    1990-01-01

    The strategy of using multiple versions of independently developed software as a means to tolerate residual software design faults is suggested by the success of hardware redundancy for tolerating hardware failures. Although, as generally accepted, the independence of hardware failures resulting from physical wearout can lead to substantial increases in reliability for redundant hardware structures, a similar conclusion is not immediate for software. The degree to which design faults are manifested as independent failures determines the effectiveness of redundancy as a method for improving software reliability. Interest in multi-version software centers on whether it provides an adequate measure of increased reliability to warrant its use in critical applications. The effectiveness of multi-version software is studied by comparing estimates of the failure probabilities of these systems with the failure probabilities of single versions. The estimates are obtained under a model of dependent failures and compared with estimates obtained when failures are assumed to be independent. The experimental results are based on twenty versions of an aerospace application developed and certified by sixty programmers from four universities. Descriptions of the application, development and certification processes, and operational evaluation are given together with an analysis of the twenty versions.

  2. Radiometric Characterization of the IKONOS, QuickBird, and OrbView-3 Sensors

    NASA Technical Reports Server (NTRS)

    Holekamp, Kara

    2006-01-01

    Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can better understand their properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, satellite at-sensor radiance values were compared to those estimated by each independent team member to determine the sensor's radiometric accuracy. The combined results of this evaluation provide the user community with an independent assessment of these commercially available high spatial resolution sensors' absolute calibration values.

  3. Radiometric Calibration Assessment of Commercial High Spatial Resolution Multispectral Image Products

    NASA Technical Reports Server (NTRS)

    Holekamp, Kara; Aaron, David; Thome, Kurtis

    2006-01-01

    Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can better understand their properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, satellite at-sensor radiance values were compared to those estimated by each independent team member to determine the sensor's radiometric accuracy. The combined results of this evaluation provide the user community with an independent assessment of these commercially available high spatial resolution sensors' absolute calibration values.

  4. Bit-wise arithmetic coding for data compression

    NASA Technical Reports Server (NTRS)

    Kiely, A. B.

    1994-01-01

    This article examines the problem of compressing a uniformly quantized independent and identically distributed (IID) source. We present a new compression technique, bit-wise arithmetic coding, that assigns fixed-length codewords to the quantizer output and uses arithmetic coding to compress the codewords, treating the codeword bits as independent. We examine the performance of this method and evaluate the overhead required when used block-adaptively. Simulation results are presented for Gaussian and Laplacian sources. This new technique could be used as the entropy coder in a transform or subband coding system.

  5. Theoretical studies of system performance and adaptive optics design parameters

    NASA Astrophysics Data System (ADS)

    Tyson, Robert K.

    1990-08-01

    The ultimate performance of an adaptive optics (AO) system can be sensitive to specific design parameters of individual components. The type and configuration of a wavefront sensor or the shape of individual deformable mirror actuator influence functions can have a profound effect on the correctability of the AO system. This paper will discuss the results of a theoretical study which employed both closed form analytic solutions and computer models. A parametric analysis of wavefront sensor characteristics, noise, and subaperture geometry are independently evaluated against system response to an aberrated wave characteristic of atmospheric turbulence. Similarly, the shape and extent of the deformable mirror influence function and the placement and number of actuators is evaluated to characterize the effects of fitting error and coupling.

  6. Evaluation Of Model Based Systems Engineering Processes For Integration Into Rapid Acquisition Programs

    DTIC Science & Technology

    2016-09-01

    Failure MTBCF Mean Time Between Critical Failure MIRV Multiple Independently-targetable Reentry Vehicle MK6LE MK6 Guidance System Life Extension...programs were the MK54 Lightweight Torpedo program, a Raytheon Radar program, and the Life Extension of the MK6 Guidance System (MK6LE) of the...activities throughout the later life -cycle phases. MBSE allowed the programs to manage the evolution of simulation capabilities, as well as to assess the

  7. 7 CFR 1218.55 - Independent evaluation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Independent evaluation. 1218.55 Section 1218.55 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... fund, from funds otherwise available to the Council, an independent evaluation of the effectiveness of...

  8. 7 CFR 1216.53 - Independent evaluation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Independent evaluation. 1216.53 Section 1216.53 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... otherwise available to the Board, an independent evaluation of the effectiveness of the Order and other...

  9. Performance evaluation of a second-generation elastic loop mobility system

    NASA Technical Reports Server (NTRS)

    Melzer, K. J.; Swanson, G. D.

    1974-01-01

    Tests were conducted to evaluate the mobility performance of a second-generation Elastic Loop Mobility System (ELMS II). Performance on level test lanes and slopes of lunar soil simulant (LSS) and obstacle-surmounting and crevasse-crossing capabilities were investigated. In addition, internal losses and contact pressure distributions were evaluated. To evaluate the soft-soil performance, two basic soil conditions were tested: loose (LSS1) and dense (LSS5). These conditions embrace the spectrum of soil strengths tested during recent studies for NASA related to the mobility performance of the LRV. Data indicated that for the tested range of the various performance parameters, performance was independent of unit load (contact pressure) and ELMS II drum angular velocity, but was influenced by soil strength and ELMS pitch mode. Power requirements were smaller at a given system output for dense soil than for loose soil. The total system output in terms of pull developed or slope-climbing capability was larger for the ELMS II operating in restrained-pitch mode than in free-pitch mode.

  10. OnlineTED.com--a novel web-based audience response system for higher education. A pilot study to evaluate user acceptance.

    PubMed

    Kühbeck, Felizian; Engelhardt, Stefan; Sarikas, Antonio

    2014-01-01

    Audience response (AR) systems are increasingly used in undergraduate medical education. However, high costs and complexity of conventional AR systems often limit their use. Here we present a novel AR system that is platform independent and does not require hardware clickers or additional software to be installed. "OnlineTED" was developed at Technische Universität München (TUM) based on Hypertext Preprocessor (PHP) with a My Structured Query Language (MySQL)-database as server- and Javascript as client-side programming languages. "OnlineTED" enables lecturers to create and manage question sets online and start polls in-class via a web-browser. Students can participate in the polls with any internet-enabled device (smartphones, tablet-PCs or laptops). A paper-based survey was conducted with undergraduate medical students and lecturers at TUM to compare "OnlineTED" with conventional AR systems using clickers. "OnlineTED" received above-average evaluation results by both students and lecturers at TUM and was seen on par or superior to conventional AR systems. The survey results indicated that up to 80% of students at TUM own an internet-enabled device (smartphone or tablet-PC) for participation in web-based AR technologies. "OnlineTED" is a novel web-based and platform-independent AR system for higher education that was well received by students and lecturers. As a non-commercial alternative to conventional AR systems it may foster interactive teaching in undergraduate education, in particular with large audiences.

  11. System Theoretic Frameworks for Mitigating Risk Complexity in the Nuclear Fuel Cycle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, Adam David; Mohagheghi, Amir H.; Cohn, Brian

    In response to the expansion of nuclear fuel cycle (NFC) activities -- and the associated suite of risks -- around the world, this project evaluated systems-based solutions for managing such risk complexity in multimodal and multi-jurisdictional international spent nuclear fuel (SNF) transportation. By better understanding systemic risks in SNF transportation, developing SNF transportation risk assessment frameworks, and evaluating these systems-based risk assessment frameworks, this research illustrated interdependency between safety, security, and safeguards risks is inherent in NFC activities and can go unidentified when each "S" is independently evaluated. Two novel system-theoretic analysis techniques -- dynamic probabilistic risk assessment (DPRA) andmore » system-theoretic process analysis (STPA) -- provide integrated "3S" analysis to address these interdependencies and the research results suggest a need -- and provide a way -- to reprioritize United States engagement efforts to reduce global nuclear risks. Lastly, this research identifies areas where Sandia National Laboratories can spearhead technical advances to reduce global nuclear dangers.« less

  12. Distributed environmental control

    NASA Technical Reports Server (NTRS)

    Cleveland, Gary A.

    1992-01-01

    We present an architecture of distributed, independent control agents designed to work with the Computer Aided System Engineering and Analysis (CASE/A) simulation tool. CASE/A simulates behavior of Environmental Control and Life Support Systems (ECLSS). We describe a lattice of agents capable of distributed sensing and overcoming certain sensor and effector failures. We address how the architecture can achieve the coordinating functions of a hierarchical command structure while maintaining the robustness and flexibility of independent agents. These agents work between the time steps of the CASE/A simulation tool to arrive at command decisions based on the state variables maintained by CASE/A. Control is evaluated according to both effectiveness (e.g., how well temperature was maintained) and resource utilization (the amount of power and materials used).

  13. [A study of factors related to activities of daily living (ADL) of the elderly receiving in-home service longitudinal study using functional independence measures].

    PubMed

    Suzuki, Ikuko; Yanagi, Hisako; Tomura, Shigeo

    2007-02-01

    We conducted a longitudinal study using Functional Independence Measures to clarify factor related to independence of activities of daily living of elderly receiving in-home service under the long-term care insurance system Fifty-four elderly users of the in-home service of Ibaraki Prefecture assented to participate in this study and were analyzed. A researcher conducted survey at the baseline and after follow-up by visiting the elderly at each home. The evaluation standards used here were the Japanese version of Functional Independence Measure (FIM), Mini-Mental State Examination (MMSE), and Geriatric Depression Scale (GDS-15). The FIM score (mean+/-SD) was decreased 83.6+/-36.4 to 81.7+/-37.4 during the 112+/-22.2 day follow up period. Thirty-nine elderly demonstrated improvement or no change in FIM and 15 had declining scores. To clarify independent factors related to FIM change, we conducted a step-wise multifactor logistic regression analysis, and the results suggested importance for "in-home service availability" and "home care period less than one year". Our study suggested that it is important for maintenance or improvement of ADL in home care elderly to provide sufficient home .care services from the beginning under the long-term care insurance system.

  14. Architectural Implications for Spatial Object Association Algorithms*

    PubMed Central

    Kumar, Vijay S.; Kurc, Tahsin; Saltz, Joel; Abdulla, Ghaleb; Kohn, Scott R.; Matarazzo, Celeste

    2013-01-01

    Spatial object association, also referred to as crossmatch of spatial datasets, is the problem of identifying and comparing objects in two or more datasets based on their positions in a common spatial coordinate system. In this work, we evaluate two crossmatch algorithms that are used for astronomical sky surveys, on the following database system architecture configurations: (1) Netezza Performance Server®, a parallel database system with active disk style processing capabilities, (2) MySQL Cluster, a high-throughput network database system, and (3) a hybrid configuration consisting of a collection of independent database system instances with data replication support. Our evaluation provides insights about how architectural characteristics of these systems affect the performance of the spatial crossmatch algorithms. We conducted our study using real use-case scenarios borrowed from a large-scale astronomy application known as the Large Synoptic Survey Telescope (LSST). PMID:25692244

  15. Evaluation and comparison of histopathologic grading systems of epithelial carcinoma of the uterine cervix: Gynecologic Oncology Group studies.

    PubMed

    Stock, R J; Zaino, R; Bundy, B N; Askin, F B; Woodward, J; Fetter, B; Paulson, J A; DiSaia, P J; Stehman, F B

    1994-04-01

    The subjects of this study are 445 patients with advanced cervical cancer treated by standardized radiation therapy. Upon entry into one of two Gynecologic Oncology Group (GOG) protocols, original pathologic diagnoses and histologic tumor descriptions for each patient were compared with separate evaluations made by a consensus opinion of two GOG pathologists. A review diagnosis using grade, cell type, and the Stendahl scoring system was then made by the first author (R.J.S.) without knowledge of the prior diagnoses. Of the original pathologists' diagnoses, 21% did not include grade or cell type. There was little agreement among the different pathologists as to the use of either specific grade or cell type. Histologic grade, irrespective of the pathologists making the diagnosis, had no correlation to prognosis. The Reagan and Wentz large-cell keratinizing (LCK) cell type, when applied by the author to tumors with any form of squamous keratinization present, identified a group of patients with a poorer prognosis, although not independently of other prognostic factors. The Stendahl scoring system identified a number of patients with both a poorer and better prognosis. This was statistically significant and independent of other risk factors. A major limitation, however, was the number of patients evaluable because of inadequate biopsy material in 23.6% of the study group.

  16. Design, Validation, and Use of an Evaluation Instrument for Monitoring Systemic Reform.

    ERIC Educational Resources Information Center

    Scantlebury, Kathryn; Boone, William; Kahle, Jane Butler; Fraser, Barry J.

    2001-01-01

    Describes the design, development, validation, and use of an instrument that measures student attitudes and several environmental dimensions (i.e., standards-based teaching, home support, and peer support). Indicates that the classroom environment (standards-based teaching practices) was the strongest independent predictor of both achievement and…

  17. Turbulent pressure fluctuations measured during CHATS

    Treesearch

    Steven P. Oncley; William J. Massman; Edward G. Patton

    2008-01-01

    Fast-response pressure fluctuations were included in the Canopy Horizontal Array of Turbulence Study (CHATS) at several heights within and just above the canopy in a walnut orchard. Two independent systems were intercompared and then separated. We present an evaluation of turbulence statistics - including the pressure transport term in the turbulence kinetic energy...

  18. Demonstration and evaluation of an innovative water main rehabilitation technology: Cured-in-Place Pipe (CIPP) lining

    EPA Science Inventory

    As many water utilities are seeking new and innovative rehabilitation technologies to extend the life of their water distribution systems, information on the capabilities and applicability of new technologies is not always readily available from an independent source. The U.S. E...

  19. Design Research as a Mechanism for Consultants to Facilitate and Evaluate Educational Innovations

    ERIC Educational Resources Information Center

    Castillo, Jose M.; Dorman, Clark; Gaunt, Brian; Hardcastle, Beth; Justice, Kelly; March, Amanda L.

    2016-01-01

    Schools across the nation are implementing innovative practices; however, questions remain regarding how to facilitate quality implementation. Research designs that emphasize high degrees of control over independent variables result in findings with internal validity, but that may not generalize to complex, dynamic educational systems. The purpose…

  20. Evaluation of IT security – genesis and its state-of-art

    NASA Astrophysics Data System (ADS)

    Livshitz, I. I.; Neklyudov, A. V.; Lontsikh, P. A.

    2018-05-01

    It is topical to evolve processes of an evaluation of the IT security nowadays. Formation and application of common evaluation approaches to the IT component, which are processed by the governmental and civil organizations, are still not solving problem. Successful processing of the independent evaluation for conformity with a security standard is supposed to be the main criteria of a suitability of any IT component to be used in a trusted computer system. The solution of the mentioned-above problem is suggested through the localization of all research, development and producing processes in a national trusted area (digital sovereignty).

  1. Research on Building Education and Workforce Capacity in Systems Engineering

    DTIC Science & Technology

    2012-01-31

    Professional Ethics Since one goal of RT-19A is to understand how best to increase the number of schools offering systems engineering capstone courses...project evaluation plan  Developed and issued the request for proposals and selection process (an independent review team and rubric) for...faculty members from both institutions talk frequently to share ideas, compare progress and clarify any issues . Auburn recruited faculty only, so

  2. MSIX - A general and user-friendly platform for RAM analysis

    NASA Astrophysics Data System (ADS)

    Pan, Z. J.; Blemel, Peter

    The authors present a CAD (computer-aided design) platform supporting RAM (reliability, availability, and maintainability) analysis with efficient system description and alternative evaluation. The design concepts, implementation techniques, and application results are described. This platform is user-friendly because of its graphic environment, drawing facilities, object orientation, self-tutoring, and access to the operating system. The programs' independency and portability make them generally applicable to various analysis tasks.

  3. Use of a novel docosahexaenoic acid formulation vs control in a neonatal porcine model of short bowel syndrome leads to greater intestinal absorption and higher systemic levels of DHA

    USDA-ARS?s Scientific Manuscript database

    Infants with short bowel syndrome (SBS) are at high risk for malabsorption, malnutrition, and failure to thrive. The objective of this study was to evaluate in a porcine model of SBS, the systemic absorption of a novel enteral Docosahexaenoic acid (DHA) formulation that forms micelles independent of...

  4. Generalizations of the subject-independent feature set for music-induced emotion recognition.

    PubMed

    Lin, Yuan-Pin; Chen, Jyh-Horng; Duann, Jeng-Ren; Lin, Chin-Teng; Jung, Tzyy-Ping

    2011-01-01

    Electroencephalogram (EEG)-based emotion recognition has been an intensely growing field. Yet, how to achieve acceptable accuracy on a practical system with as fewer electrodes as possible is less concerned. This study evaluates a set of subject-independent features, based on differential power asymmetry of symmetric electrode pairs [1], with emphasis on its applicability to subject variability in music-induced emotion classification problem. Results of this study have evidently validated the feasibility of using subject-independent EEG features to classify four emotional states with acceptable accuracy in second-scale temporal resolution. These features could be generalized across subjects to detect emotion induced by music excerpts not limited to the music database that was used to derive the emotion-specific features.

  5. Theranostic Imaging of Cancer Gene Therapy.

    PubMed

    Sekar, Thillai V; Paulmurugan, Ramasamy

    2016-01-01

    Gene-directed enzyme prodrug therapy (GDEPT) is a promising therapeutic approach for treating cancers of various phenotypes. This strategy is independent of various other chemotherapeutic drugs used for treating cancers where the drugs are mainly designed to target endogenous cellular mechanisms, which are different in various cancer subtypes. In GDEPT an external enzyme, which is different from the cellular proteins, is expressed to convert the injected prodrug in to a toxic metabolite, that normally kill cancer cells express this protein. Theranostic imaging is an approach used to directly monitor the expression of these gene therapy enzymes while evaluating therapeutic effect. We recently developed a dual-GDEPT system where we combined mutant human herpes simplex thymidine kinase (HSV1sr39TK) and E. coli nitroreductase (NTR) enzyme, to improve therapeutic efficiency of cancer gene therapy by simultaneously injecting two prodrugs at a lower dose. In this approach we use two different prodrugs such as ganciclovir (GCV) and CB1954 to target two different cellular mechanisms to kill cancer cells. The developed dual GDEPT system was highly efficacious than that of either of the system used independently. In this chapter, we describe the complete protocol involved for in vitro and in vivo imaging of therapeutic cancer gene therapy evaluation.

  6. DC current distribution mapping system of the solar panels using a HTS-SQUID gradiometer

    NASA Astrophysics Data System (ADS)

    Miyazaki, Shingo; Kasuya, Syohei; Mawardi Saari, Mohd; Sakai, Kenji; Kiwa, Toshihiko; Tsukamoto, Akira; Adachi, Seiji; Tanabe, Keiichi; Tsukada, Keiji

    2014-05-01

    Solar panels are expected to play a major role as a source of sustainable energy. In order to evaluate solar panels, non-destructive tests, such as defect inspections and response property evaluations, are necessary. We developed a DC current distribution mapping system of the solar panels using a High Critical Temperature Superconductor Superconducting Quantum Interference Device (HTS-SQUID) gradiometer with ramp edge type Josephson junctions. Two independent components of the magnetic fields perpendicular to the panel surface (∂Bz/∂x, ∂Bz/∂y) were detected. The direct current of the solar panel is visualized by calculating the composition of the two signal components, the phase angle, and mapping the DC current vector. The developed system can evaluate the uniformity of DC current distributions precisely and may be applicable for defect detection of solar panels.

  7. The UK Earth System Models Marine Biogeochemical Evaluation Toolkit, BGC-val

    NASA Astrophysics Data System (ADS)

    de Mora, Lee

    2017-04-01

    The Biogeochemical Validation toolkit, BGC-val, is a model and grid independent python-based marine model evaluation framework that automates much of the validation of the marine component of an Earth System Model. BGC-val was initially developed to be a flexible and extensible system to evaluate the spin up of the marine UK Earth System Model (UKESM). However, the grid-independence and flexibility means that it is straightforward to adapt the BGC-val framework to evaluate other marine models. In addition to the marine component of the UKESM, this toolkit has been adapted to compare multiple models, including models from the CMIP5 and iMarNet inter-comparison projects. The BGC-val toolkit produces multiple levels of analysis which are presented in a simple to use interactive html5 document. Level 1 contains time series analyses, showing the development over time of many important biogeochemical and physical ocean metrics, such as the Global primary production or the Drake passage current. The second level of BGC-val is an in-depth spatial analyses of a single point in time. This is a series of point to point comparison of model and data in various regions, such as a comparison of Surface Nitrate in the model vs data from the world ocean atlas. The third level analyses are specialised ad-hoc packages to go in-depth on a specific question, such as the development of Oxygen minimum zones in the Equatorial Pacific. In additional to the three levels, the html5 document opens with a Level 0 table showing a summary of the status of the model run. The beta version of this toolkit is available via the Plymouth Marine Laboratory Gitlab server and uses the BSD 3 clause license.

  8. [Evaluation and prioritisation of the scientific research in Spain. Researchers' point of view].

    PubMed

    María Martín-Moreno, José; Juan Toharia, José; Gutiérrez Fuentes, José Antonio

    2008-12-01

    The assessment and prioritisation of research activity are essential components of any Science, Technology and Industry System. Data on researchers' perspectives in this respect are scarce. The objective of this paper was to describe Spanish scientists' point of view on the current evaluation system in Spain and how they believe this system should be functionally structured. From the sampling frame formed by established Spanish scientists, listed in the databases of CSIC and FIS (Institute of Health Carlos III), clinical, biomedical-non clinical, and physics and chemical researchers were randomly selected. Two hundred and eleven interviews were carried out by means of a computer-assisted telephone interviewing system. Researchers expressed their acknowledgement of progress in the Spanish research field but made their wish clear to progress towards better scientific scenarios. In their assessment, they gave a score of 5.4 to scientific policy, as opposed to 9.4 when speaking about the goals, reflecting the desire for a better policy definition, with clear objectives, stable strategies and better coordination of R&D activities (the current coordination received a score of 3.9, while the desirable coordination was valued as high as 9.2). There was certain agreement regarding the need for a prioritisation criteria which preserves some degree of creativity by researchers. They also stated that they would like to see an independent research structure with social prestige and influence. The interviewed researchers believe that the evaluation of scientific activities is fundamental in formulating a sound scientific policy. Prioritisation should arise from appropriate evaluation. Strategies properly coordinated among all the stakeholders (including the private sector) should be fostered. Budget sufficiency, stability, and better organization of independent researchers should be the backbone of any strategy tailored to increase their capacity to influence future scientific policies.

  9. High-density digital recording

    NASA Technical Reports Server (NTRS)

    Kalil, F. (Editor); Buschman, A. (Editor)

    1985-01-01

    The problems associated with high-density digital recording (HDDR) are discussed. Five independent users of HDDR systems and their problems, solutions, and insights are provided as guidance for other users of HDDR systems. Various pulse code modulation coding techniques are reviewed. An introduction to error detection and correction head optimization theory and perpendicular recording are provided. Competitive tape recorder manufacturers apply all of the above theories and techniques and present their offerings. The methodology used by the HDDR Users Subcommittee of THIC to evaluate parallel HDDR systems is presented.

  10. Evaluation of an Integrated Gas-Cooled Reactor Simulator and Brayton Turbine-Generator

    NASA Technical Reports Server (NTRS)

    Hissam, David Andy; Stewart, Eric T.

    2006-01-01

    A closed-loop brayton cycle, powered by a fission reactor, offers an attractive option for generating both planetary and in-space electric power. Non-nuclear testing of this type of system provides the opportunity to safely work out integration and system control challenges for a modest investment. Recognizing this potential, a team at Marshall Space Flight Center has evaluated the viability of integrating and testing an existing gas-cooled reactor simulator and a modified commercially available, off-the-shelf, brayton turbine-generator. Since these two systems were developed independently of one another, this evaluation had to determine if they could operate together at acceptable power levels, temperatures, and pressures. Thermal, fluid, and structural analyses show that this combined system can operate at acceptable power levels and temperatures. In addition, pressure drops across the reactor simulator, although higher than desired, are also viewed as acceptable. Three potential working fluids for the system were evaluated: N2, He/Ar, and He/Xe. Other potential issues, such as electrical breakdown in the generator and the operation of the brayton foil bearings using various gas mixtures, were also investigated.

  11. Exploratory data analysis of acceleration signals to select light-weight and accurate features for real-time activity recognition on smartphones.

    PubMed

    Khan, Adil Mehmood; Siddiqi, Muhammad Hameed; Lee, Seok-Won

    2013-09-27

    Smartphone-based activity recognition (SP-AR) recognizes users' activities using the embedded accelerometer sensor. Only a small number of previous works can be classified as online systems, i.e., the whole process (pre-processing, feature extraction, and classification) is performed on the device. Most of these online systems use either a high sampling rate (SR) or long data-window (DW) to achieve high accuracy, resulting in short battery life or delayed system response, respectively. This paper introduces a real-time/online SP-AR system that solves this problem. Exploratory data analysis was performed on acceleration signals of 6 activities, collected from 30 subjects, to show that these signals are generated by an autoregressive (AR) process, and an accurate AR-model in this case can be built using a low SR (20 Hz) and a small DW (3 s). The high within class variance resulting from placing the phone at different positions was reduced using kernel discriminant analysis to achieve position-independent recognition. Neural networks were used as classifiers. Unlike previous works, true subject-independent evaluation was performed, where 10 new subjects evaluated the system at their homes for 1 week. The results show that our features outperformed three commonly used features by 40% in terms of accuracy for the given SR and DW.

  12. In-situ implant containing PCL-curcumin nanoparticles developed using design of experiments.

    PubMed

    Kasinathan, Narayanan; Amirthalingam, Muthukumar; Reddy, Neetinkumar D; Jagani, Hitesh V; Volety, Subrahmanyam M; Rao, Josyula Venkata

    2016-01-01

    Polymeric delivery system is useful in reducing pharmacokinetic limitations viz., poor absorption and rapid elimination associated with clinical use of curcumin. Design of experiment is a precise and cost effective tool useful in analyzing the effect of independent variables and their interaction on the product attributes. To evaluate the effect of process variables involved in preparation of curcumin-loaded polycaprolactone (PCL) nanoparticles (CPN). In the present experiment, CPNs were prepared by emulsification solvent evaporation technique. The effect of independent variables on the dependent variable was analyzed using design of experiments. Anticancer activity of CPN was studied using Ehrlich ascites carcinoma (EAC) model. In-situ implant was developed using PLGA as polymer. The effect of independent variables was studied in two stages. First, the effect of drug-polymer ratio, homogenization speed and surfactant concentration on size was studied using factorial design. The interaction of homogenization speed with homogenization time on mean particle size of CPN was then evaluated using central composite design. In the second stage, the effect of these variables (under the conditions optimized for producing particles <500 nm) on percentage drug encapsulation was evaluated using factorial design. CPN prepared under optimized conditions were able to control the development of EAC in Swiss albino mice and enhanced their survival time. PLGA based in-situ implant containing CPN prepared under optimized conditions showed sustained drug release. This implant could be further evaluated for pharmacological activities.

  13. Using a data base management system for modelling SSME test history data

    NASA Technical Reports Server (NTRS)

    Abernethy, K.

    1985-01-01

    The usefulness of a data base management system (DBMS) for modelling historical test data for the complete series of static test firings for the Space Shuttle Main Engine (SSME) was assessed. From an analysis of user data base query requirements, it became clear that a relational DMBS which included a relationally complete query language would permit a model satisfying the query requirements. Representative models and sample queries are discussed. A list of environment-particular evaluation criteria for the desired DBMS was constructed; these criteria include requirements in the areas of user-interface complexity, program independence, flexibility, modifiability, and output capability. The evaluation process included the construction of several prototype data bases for user assessement. The systems studied, representing the three major DBMS conceptual models, were: MIRADS, a hierarchical system; DMS-1100, a CODASYL-based network system; ORACLE, a relational system; and DATATRIEVE, a relational-type system.

  14. Design, construction and evaluation of a system of forced solar water heating.

    NASA Astrophysics Data System (ADS)

    Hernández, E.; Bautista, G. A.; Ortiz, I. L.

    2016-07-01

    The main purpose of this project was to design, construct and evaluate a system of forced solar water heating for domestic consumption, at the Universidad Pontificia Bolivariana-Bucaramanga, Colombia; using solar energy. This is a totally system independent of the electrical grid and an important characteristic is the heating water doesn't mix with the consumption water. The system receives the solar radiation through a flat-plate collector, which it transmits the heat to the water that it flow with impulse from the centrifugal pump of 12VDC, the water circulates toward helical serpentine it is inside of the tank of the storage whose capacity is 100 liters of water. The temperature of the tank is regulated with a controller in such a way that de-energized the pump when it gets the temperature required. The performance thermal or efficiency of the system was evaluated like a relationship between the delivered energy to the water in storage tank and the incident energy in the flat-plate collector.

  15. Identification of terms to define unconstrained air transportation demands

    NASA Technical Reports Server (NTRS)

    Jacobson, I. D.; Kuhilhau, A. R.

    1982-01-01

    The factors involved in the evaluation of unconstrained air transportation systems were carefully analyzed. By definition an unconstrained system is taken to be one in which the design can employ innovative and advanced concepts no longer limited by present environmental, social, political or regulatory settings. Four principal evaluation criteria are involved: (1) service utilization, based on the operating performance characteristics as viewed by potential patrons; (2) community impacts, reflecting decisions based on the perceived impacts of the system; (3) technological feasibility, estimating what is required to reduce the system to practice; and (4) financial feasibility, predicting the ability of the concepts to attract financial support. For each of these criteria, a set of terms or descriptors was identified, which should be used in the evaluation to render it complete. It is also demonstrated that these descriptors have the following properties: (a) their interpretation may be made by different groups of evaluators; (b) their interpretations and the way they are used may depend on the stage of development of the system in which they are used; (c) in formulating the problem, all descriptors should be addressed independent of the evaluation technique selected.

  16. Independent Orbiter Assessment (IOA): Analysis of the DPS subsystem

    NASA Technical Reports Server (NTRS)

    Lowery, H. J.; Haufler, W. A.; Pietz, K. C.

    1986-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis/Critical Items List (FMEA/CIL) is presented. The IOA approach features a top-down analysis of the hardware to independently determine failure modes, criticality, and potential critical items. The independent analysis results corresponding to the Orbiter Data Processing System (DPS) hardware are documented. The DPS hardware is required for performing critical functions of data acquisition, data manipulation, data display, and data transfer throughout the Orbiter. Specifically, the DPS hardware consists of the following components: Multiplexer/Demultiplexer (MDM); General Purpose Computer (GPC); Multifunction CRT Display System (MCDS); Data Buses and Data Bus Couplers (DBC); Data Bus Isolation Amplifiers (DBIA); Mass Memory Unit (MMU); and Engine Interface Unit (EIU). The IOA analysis process utilized available DPS hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Due to the extensive redundancy built into the DPS the number of critical items are few. Those identified resulted from premature operation and erroneous output of the GPCs.

  17. Adaptive sleep-wake discrimination for wearable devices.

    PubMed

    Karlen, Walter; Floreano, Dario

    2011-04-01

    Sleep/wake classification systems that rely on physiological signals suffer from intersubject differences that make accurate classification with a single, subject-independent model difficult. To overcome the limitations of intersubject variability, we suggest a novel online adaptation technique that updates the sleep/wake classifier in real time. The objective of the present study was to evaluate the performance of a newly developed adaptive classification algorithm that was embedded on a wearable sleep/wake classification system called SleePic. The algorithm processed ECG and respiratory effort signals for the classification task and applied behavioral measurements (obtained from accelerometer and press-button data) for the automatic adaptation task. When trained as a subject-independent classifier algorithm, the SleePic device was only able to correctly classify 74.94 ± 6.76% of the human-rated sleep/wake data. By using the suggested automatic adaptation method, the mean classification accuracy could be significantly improved to 92.98 ± 3.19%. A subject-independent classifier based on activity data only showed a comparable accuracy of 90.44 ± 3.57%. We demonstrated that subject-independent models used for online sleep-wake classification can successfully be adapted to previously unseen subjects without the intervention of human experts or off-line calibration.

  18. Independent Orbiter Assessment (IOA): Analysis of the hydraulics/water spray boiler subsystem

    NASA Technical Reports Server (NTRS)

    Duval, J. D.; Davidson, W. R.; Parkman, William E.

    1986-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items (PCIs). To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results for the Orbiter Hydraulics/Water Spray Boiler Subsystem. The hydraulic system provides hydraulic power to gimbal the main engines, actuate the main engine propellant control valves, move the aerodynamic flight control surfaces, lower the landing gear, apply wheel brakes, steer the nosewheel, and dampen the external tank (ET) separation. Each hydraulic system has an associated water spray boiler which is used to cool the hydraulic fluid and APU lubricating oil. The IOA analysis process utilized available HYD/WSB hardware drawings, schematics and documents for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 430 failure modes analyzed, 166 were determined to be PCIs.

  19. Independent Orbiter Assessment (IOA): Analysis of the remote manipulator system

    NASA Technical Reports Server (NTRS)

    Tangorra, F.; Grasmeder, R. F.; Montgomery, A. D.

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items (PCIs). To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results for the Orbiter Remote Manipulator System (RMS) are documented. The RMS hardware and software are primarily required for deploying and/or retrieving up to five payloads during a single mission, capture and retrieve free-flying payloads, and for performing Manipulator Foot Restraint operations. Specifically, the RMS hardware consists of the following components: end effector; displays and controls; manipulator controller interface unit; arm based electronics; and the arm. The IOA analysis process utilized available RMS hardware drawings, schematics and documents for defining hardware assemblies, components and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 574 failure modes analyzed, 413 were determined to be PCIs.

  20. Sample-independent approach to normalize two-dimensional data for orthogonality evaluation using whole separation space scaling.

    PubMed

    Jáčová, Jaroslava; Gardlo, Alžběta; Friedecký, David; Adam, Tomáš; Dimandja, Jean-Marie D

    2017-08-18

    Orthogonality is a key parameter that is used to evaluate the separation power of chromatography-based two-dimensional systems. It is necessary to scale the separation data before the assessment of the orthogonality. Current scaling approaches are sample-dependent, and the extent of the retention space that is converted into a normalized retention space is set according to the retention times of the first and last analytes contained in a unique sample to elute. The presence or absence of a highly retained analyte in a sample can thus significantly influence the amount of information (in terms of the total amount of separation space) contained in the normalized retention space considered for the calculation of the orthogonality. We propose a Whole Separation Space Scaling (WOSEL) approach that accounts for the whole separation space delineated by the analytical method, and not the sample. This approach enables an orthogonality-based evaluation of the efficiency of the analytical system that is independent of the sample selected. The WOSEL method was compared to two currently used orthogonality approaches through the evaluation of in silico-generated chromatograms and real separations of human biofluids and petroleum samples. WOSEL exhibits sample-to-sample stability values of 3.8% on real samples, compared to 7.0% and 10.1% for the two other methods, respectively. Using real analyses, we also demonstrate that some previously developed approaches can provide misleading conclusions on the overall orthogonality of a two-dimensional chromatographic system. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. An O(N) and parallel approach to integral problems by a kernel-independent fast multipole method: Application to polarization and magnetization of interacting particles

    NASA Astrophysics Data System (ADS)

    Jiang, Xikai; Li, Jiyuan; Zhao, Xujun; Qin, Jian; Karpeev, Dmitry; Hernandez-Ortiz, Juan; de Pablo, Juan J.; Heinonen, Olle

    2016-08-01

    Large classes of materials systems in physics and engineering are governed by magnetic and electrostatic interactions. Continuum or mesoscale descriptions of such systems can be cast in terms of integral equations, whose direct computational evaluation requires O(N2) operations, where N is the number of unknowns. Such a scaling, which arises from the many-body nature of the relevant Green's function, has precluded wide-spread adoption of integral methods for solution of large-scale scientific and engineering problems. In this work, a parallel computational approach is presented that relies on using scalable open source libraries and utilizes a kernel-independent Fast Multipole Method (FMM) to evaluate the integrals in O(N) operations, with O(N) memory cost, thereby substantially improving the scalability and efficiency of computational integral methods. We demonstrate the accuracy, efficiency, and scalability of our approach in the context of two examples. In the first, we solve a boundary value problem for a ferroelectric/ferromagnetic volume in free space. In the second, we solve an electrostatic problem involving polarizable dielectric bodies in an unbounded dielectric medium. The results from these test cases show that our proposed parallel approach, which is built on a kernel-independent FMM, can enable highly efficient and accurate simulations and allow for considerable flexibility in a broad range of applications.

  2. Creating a performance appraisal template for pharmacy technicians using the method of equal-appearing intervals.

    PubMed

    Desselle, Shane P; Vaughan, Melissa; Faria, Thomas

    2002-01-01

    To design a highly quantitative template for the evaluation of community pharmacy technicians' job performance that enables managers to provide sufficient feedback and fairly allocate organizational rewards. Two rounds of interviews with two convenience samples of community pharmacists and pharmacy technicians were conducted. The interview in phase 1 was qualitative, and responses were used to design the second interview protocol. During the phase 2 interviews, a new group of respondents ranked technicians' job responsibilities, identified through the initial interviewees' responses, using scales the researchers had designed using an interval-level scaling technique called equal-appearing intervals. Chain and independent pharmacies. Phase 1-20 pharmacists and 20 technicians from chain and independent pharmacies; phase 2-20 pharmacists and 9 technicians from chain and independent pharmacies. Ratings of the importance of technician practice functions and corresponding responsibilities. Weights were calculated for each practice function. A weighted list of practice functions was developed, and this may serve as a performance evaluation template. Customer service-related activities were judged by pharmacists and technicians alike to be the most important technician functions. Many pharmacies either lack formal performance appraisal systems or fail to implement them properly. Technicians may desire more consistent feedback from pharmacists and value information that may lead to organizational rewards. Using a weighted, behaviorally anchored performance appraisal system may help pharmacists and pharmacy managers meet these demands.

  3. An O( N) and parallel approach to integral problems by a kernel-independent fast multipole method: Application to polarization and magnetization of interacting particles

    DOE PAGES

    Jiang, Xikai; Li, Jiyuan; Zhao, Xujun; ...

    2016-08-10

    Large classes of materials systems in physics and engineering are governed by magnetic and electrostatic interactions. Continuum or mesoscale descriptions of such systems can be cast in terms of integral equations, whose direct computational evaluation requires O( N 2) operations, where N is the number of unknowns. Such a scaling, which arises from the many-body nature of the relevant Green's function, has precluded wide-spread adoption of integral methods for solution of large-scale scientific and engineering problems. In this work, a parallel computational approach is presented that relies on using scalable open source libraries and utilizes a kernel-independent Fast Multipole Methodmore » (FMM) to evaluate the integrals in O( N) operations, with O( N) memory cost, thereby substantially improving the scalability and efficiency of computational integral methods. We demonstrate the accuracy, efficiency, and scalability of our approach in the context of two examples. In the first, we solve a boundary value problem for a ferroelectric/ferromagnetic volume in free space. In the second, we solve an electrostatic problem involving polarizable dielectric bodies in an unbounded dielectric medium. Lastly, the results from these test cases show that our proposed parallel approach, which is built on a kernel-independent FMM, can enable highly efficient and accurate simulations and allow for considerable flexibility in a broad range of applications.« less

  4. Independent Orbiter Assessment (IOA): Analysis of the orbiter main propulsion system

    NASA Technical Reports Server (NTRS)

    Mcnicoll, W. J.; Mcneely, M.; Holden, K. A.; Emmons, T. E.; Lowery, H. J.

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items (PCIs). To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results for the Orbiter Main Propulsion System (MPS) hardware are documented. The Orbiter MPS consists of two subsystems: the Propellant Management Subsystem (PMS) and the Helium Subsystem. The PMS is a system of manifolds, distribution lines and valves by which the liquid propellants pass from the External Tank (ET) to the Space Shuttle Main Engines (SSMEs) and gaseous propellants pass from the SSMEs to the ET. The Helium Subsystem consists of a series of helium supply tanks and their associated regulators, check valves, distribution lines, and control valves. The Helium Subsystem supplies helium that is used within the SSMEs for inflight purges and provides pressure for actuation of SSME valves during emergency pneumatic shutdowns. The balance of the helium is used to provide pressure to operate the pneumatically actuated valves within the PMS. Each component was evaluated and analyzed for possible failure modes and effects. Criticalities were assigned based on the worst possible effect of each failure mode. Of the 690 failure modes analyzed, 349 were determined to be PCIs.

  5. Active depth-guiding handheld micro-forceps for membranectomy based on CP-SSOCT

    NASA Astrophysics Data System (ADS)

    Cheon, Gyeong Woo; Lee, Phillip; Gonenc, Berk; Gehlbach, Peter L.; Kang, Jin U.

    2016-03-01

    In this study, we demonstrate a handheld motion-compensated micro-forceps system using common-path swept source optical coherence tomography with highly accurate depth-targeting and depth-locking for Epiretinal Membrane Peeling. Two motors and a touch sensor were used to separate the two independent motions: motion compensation and tool-tip manipulation. A smart motion monitoring and guiding algorithm was devised for precise and intuitive freehand control. Ex-vivo bovine eye experiments were performed to evaluate accuracy in a bovine retina retinal membrane peeling model. The evaluation demonstrates system capabilities of 40 um accuracy when peeling the epithelial layer of bovine retina.

  6. High prolactin levels are independently associated with damage accrual in systemic lupus erythematosus patients.

    PubMed

    Ugarte-Gil, M F; Gamboa-Cárdenas, R V; Zevallos, F; Medina, M; Cucho-Venegas, J M; Perich-Campos, R A; Alfaro-Lozano, J L; Rodriguez-Bellido, Z; Alarcón, G S; Pastor-Asurza, C A

    2014-09-01

    to determine whether prolactin levels are independently associated with disease damage in systemic lupus erythematosus (SLE) patients. these cross-sectional analyses were conducted in SLE patient members of the Almenara Lupus Cohort who were seen between January 2012 and June 2013. Disease damage was ascertained with the System Lupus International Collaborating Clinics/American College of Rheumatology (SLICC/ACR) damage index (SDI). Prolactin was measured in ng/ml. The association between prolactin levels and the SDI (total and its domains) was evaluated using Spearman's correlation. Subsequently, adjusted Poisson regression models were performed to evaluate these associations. 160 patients were included. 147 (91.9%) were female; their median age at diagnosis was 33.4 (interquartile range (IQR): 26.0-44.3) years; their disease duration was 5.5 (IQR: 2.6-9.7) years. The median prolactin value was 16.8 (IQR: 11.8-24.5) ng/ml. After adjusting for confounders in the Poisson regression model the estimated rate ratios (RR) and 95% confidence interval (CI) for each 10 ng/ml increment of prolactin were 1.13 (95% CI 1.60-1.20, p<0.001) for the total SDI score, 1.15 (1.03-1.28, p=0.003) for the renal domain and 1.41 (1.11-1.79, p=0.003) for the cardiac/peripheral vascular domains. there was a positive association between prolactin levels and the SDI (overall and its renal and cardiac/peripheral vascular domains), independently of other well-known risk factors. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. Generalized math model for simulation of high-altitude balloon systems

    NASA Technical Reports Server (NTRS)

    Nigro, N. J.; Elkouh, A. F.; Hinton, D. E.; Yang, J. K.

    1985-01-01

    Balloon systems have proved to be a cost-effective means for conducting research experiments (e.g., infrared astronomy) in the earth's atmosphere. The purpose of this paper is to present a generalized mathematical model that can be used to simulate the motion of these systems once they have attained float altitude. The resulting form of the model is such that the pendulation and spin motions of the system are uncoupled and can be analyzed independently. The model is evaluated by comparing the simulation results with data obtained from an actual balloon system flown by NASA.

  8. Evaluation of earthquake and tsunami on JSFR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chikazawa, Y.; Enuma, Y.; Kisohara, N.

    2012-07-01

    Evaluation of earthquake and tsunami on JSFR has been analyzed. For seismic design, safety components are confirmed to maintain their functions even against recent strong earthquakes. As for Tsunami, some parts of reactor building might be submerged including component cooling water system whose final heat sink is sea water. However, in the JSFR design, safety grade components are independent from component cooling water system (CCWS). The JSFR emergency power supply adopts a gas turbine system with air cooling, since JSFR does not basically require quick start-up of the emergency power supply thanks to the natural convection DHRS. Even in casemore » of long station blackout, the DHRS could be activated by emergency batteries or manually and be operated continuously by natural convection. (authors)« less

  9. Urban School Chiefs Under Fire.

    ERIC Educational Resources Information Center

    Cuban, Larry

    This study examines three veteran urban school superintendents who were highly respected by their colleagues but who came under intense pressure from forces outside the school systems in the 1960's. Chapter 1 explores the context of the desegregation controversy and the furor over an independent evaluation that faced Benjamin C. Willis in Chicago.…

  10. Economic competiveness of napier grass in irrigated and non-irrigated Georgia Coastal Plain cropping systems.

    USDA-ARS?s Scientific Manuscript database

    The Energy Independence Security Act (EISA) of 2007 mandated an increase in the use of advance biofuels to 21 billion gallons by 2022. As a result, numerous perennial warm-season grasses have been introduced and management practices evaluated to determine their suitability as biofuel feedstocks. Whi...

  11. Ground Vehicle Power and Mobility Overview - Germany Visit

    DTIC Science & Technology

    2011-11-10

    the current and future force Survivability Robotics – Intelligent Systems Vehicle Electronics & Architecture Fuel, Water, Bridging ...Test Cell • Engine Generator Test Lab • Full Vehicle Environmental Test Cell • Hybrid Electric Reconfigurable Moveable Integration Testbed (HERMIT...Converter Conducted competitive runoff evaluations on Bridging Boat engine candidates Completed independent durability assessment of OEM

  12. Training and Generalization of Peer-Directed Mands with Non-Vocal Children with Autism

    ERIC Educational Resources Information Center

    Kodak, Tiffany; Paden, Amber; Dickes, Nitasha

    2012-01-01

    The current investigation evaluated the effects of extinction and prompts on training and generalization of peer-directed mands for preferred items using a picture exchange communication system with 2 children diagnosed with autism. Results showed that independent mands with a peer increased during treatment for both participants, generalized to a…

  13. Architectural Implications for Spatial Object Association Algorithms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, V S; Kurc, T; Saltz, J

    2009-01-29

    Spatial object association, also referred to as cross-match of spatial datasets, is the problem of identifying and comparing objects in two or more datasets based on their positions in a common spatial coordinate system. In this work, we evaluate two crossmatch algorithms that are used for astronomical sky surveys, on the following database system architecture configurations: (1) Netezza Performance Server R, a parallel database system with active disk style processing capabilities, (2) MySQL Cluster, a high-throughput network database system, and (3) a hybrid configuration consisting of a collection of independent database system instances with data replication support. Our evaluation providesmore » insights about how architectural characteristics of these systems affect the performance of the spatial crossmatch algorithms. We conducted our study using real use-case scenarios borrowed from a large-scale astronomy application known as the Large Synoptic Survey Telescope (LSST).« less

  14. SPI/U3.2. Security Profile Inspector for UNIX Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartoletti, A.

    1994-08-01

    SPI/U3.2 consists of five tools used to assess and report the security posture of computers running the UNIX operating system. The tools are: Access Control Test: A rule-based system which identifies sequential dependencies in UNIX access controls. Binary Authentication Tool: Evaluates the release status of system binaries by comparing a crypto-checksum to provide table entries. Change Detection Tool: Maintains and applies a snapshot of critical system files and attributes for purposes of change detection. Configuration Query Language: Accepts CQL-based scripts (provided) to evaluate queries over the status of system files, configuration of services and many other elements of UNIX systemmore » security. Password Security Inspector: Tests for weak or aged passwords. The tools are packaged with a forms-based user interface providing on-line context-sensistive help, job scheduling, parameter management and output report management utilities. Tools may be run independent of the UI.« less

  15. Versatile robotic interface to evaluate, enable and train locomotion and balance after neuromotor disorders.

    PubMed

    Dominici, Nadia; Keller, Urs; Vallery, Heike; Friedli, Lucia; van den Brand, Rubia; Starkey, Michelle L; Musienko, Pavel; Riener, Robert; Courtine, Grégoire

    2012-07-01

    Central nervous system (CNS) disorders distinctly impair locomotor pattern generation and balance, but technical limitations prevent independent assessment and rehabilitation of these subfunctions. Here we introduce a versatile robotic interface to evaluate, enable and train pattern generation and balance independently during natural walking behaviors in rats. In evaluation mode, the robotic interface affords detailed assessments of pattern generation and dynamic equilibrium after spinal cord injury (SCI) and stroke. In enabling mode,the robot acts as a propulsive or postural neuroprosthesis that instantly promotes unexpected locomotor capacities including overground walking after complete SCI, stair climbing following partial SCI and precise paw placement shortly after stroke. In training mode, robot-enabled rehabilitation, epidural electrical stimulation and monoamine agonists reestablish weight-supported locomotion, coordinated steering and balance in rats with a paralyzing SCI. This new robotic technology and associated concepts have broad implications for both assessing and restoring motor functions after CNS disorders, both in animals and in humans.

  16. OnlineTED.com − a novel web-based audience response system for higher education. A pilot study to evaluate user acceptance

    PubMed Central

    Kühbeck, Felizian; Engelhardt, Stefan; Sarikas, Antonio

    2014-01-01

    Background and aim: Audience response (AR) systems are increasingly used in undergraduate medical education. However, high costs and complexity of conventional AR systems often limit their use. Here we present a novel AR system that is platform independent and does not require hardware clickers or additional software to be installed. Methods and results: “OnlineTED” was developed at Technische Universität München (TUM) based on Hypertext Preprocessor (PHP) with a My Structured Query Language (MySQL)-database as server- and Javascript as client-side programming languages. “OnlineTED” enables lecturers to create and manage question sets online and start polls in-class via a web-browser. Students can participate in the polls with any internet-enabled device (smartphones, tablet-PCs or laptops). A paper-based survey was conducted with undergraduate medical students and lecturers at TUM to compare "OnlineTED" with conventional AR systems using clickers. "OnlineTED" received above-average evaluation results by both students and lecturers at TUM and was seen on par or superior to conventional AR systems. The survey results indicated that up to 80% of students at TUM own an internet-enabled device (smartphone or tablet-PC) for participation in web-based AR technologies. Summary and Conclusion: “OnlineTED” is a novel web-based and platform-independent AR system for higher education that was well received by students and lecturers. As a non-commercial alternative to conventional AR systems it may foster interactive teaching in undergraduate education, in particular with large audiences. PMID:24575156

  17. Nurturing Professional Growth: A Peer Review Model for Independent Evaluators

    ERIC Educational Resources Information Center

    Bond, Sally L.; Ray, Marilyn L.

    2006-01-01

    There has been a recent groundswell of support in the American Evaluation Association's Independent Consulting Topical Interest Group (IC TIG) for evaluating evaluators' work just as evaluators evaluate the work of their clients. To facilitate this self-evaluation, the IC TIG elected to create a peer review process that focuses on written…

  18. Use of HPLC/UPLC-spectrophotometry for detection of formazan in in vitro Reconstructed human Tissue (RhT)-based test methods employing the MTT-reduction assay to expand their applicability to strongly coloured test chemicals.

    PubMed

    Alépée, N; Barroso, J; De Smedt, A; De Wever, B; Hibatallah, J; Klaric, M; Mewes, K R; Millet, M; Pfannenbecker, U; Tailhardat, M; Templier, M; McNamee, P

    2015-06-01

    A number of in vitro test methods using Reconstructed human Tissues (RhT) are regulatory accepted for evaluation of skin corrosion/irritation. In such methods, test chemical corrosion/irritation potential is determined by measuring tissue viability using the photometric MTT-reduction assay. A known limitation of this assay is possible interference of strongly coloured test chemicals with measurement of formazan by absorbance (OD). To address this, Cosmetics Europe evaluated use of HPLC/UPLC-spectrophotometry as an alternative formazan measurement system. Using the approach recommended by the FDA guidance for validation of bio-analytical methods, three independent laboratories established and qualified their HPLC/UPLC-spectrophotometry systems to reproducibly measure formazan from tissue extracts. Up to 26 chemicals were then tested in RhT test systems for eye/skin irritation and skin corrosion. Results support that: (1) HPLC/UPLC-spectrophotometry formazan measurement is highly reproducible; (2) formazan measurement by HPLC/UPLC-spectrophotometry and OD gave almost identical tissue viabilities for test chemicals not exhibiting colour interference nor direct MTT reduction; (3) independent of the test system used, HPLC/UPLC-spectrophotometry can measure formazan for strongly coloured test chemicals when this is not possible by absorbance only. It is therefore recommended that HPLC/UPLC-spectrophotometry to measure formazan be included in the procedures of in vitro RhT-based test methods, irrespective of the test system used and the toxicity endpoint evaluated to extend the applicability of these test methods to strongly coloured chemicals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Post-Flight Analysis of GPSR Performance During Orion Exploration Flight Test 1

    NASA Technical Reports Server (NTRS)

    Barker, Lee; Mamich, Harvey; McGregor, John

    2016-01-01

    On 5 December 2014, the first test flight of the Orion Multi-Purpose Crew Vehicle executed a unique and challenging flight profile including an elevated re-entry velocity and steeper flight path angle to envelope lunar re-entry conditions. A new navigation system including a single frequency (L1) GPS receiver was evaluated for use as part of the redundant navigation system required for human space flight. The single frequency receiver was challenged by a highly dynamic flight environment including flight above low Earth orbit, as well as single frequency operation with ionospheric delay present. This paper presents a brief description of the GPS navigation system, an independent analysis of flight telemetry data, and evaluation of the GPSR performance, including evaluation of the ionospheric model employed to supplement the single frequency receiver. Lessons learned and potential improvements will be discussed.

  20. Adapting Nielsen’s Design Heuristics to Dual Processing for Clinical Decision Support

    PubMed Central

    Taft, Teresa; Staes, Catherine; Slager, Stacey; Weir, Charlene

    2016-01-01

    The study objective was to improve the applicability of Nielson’s standard design heuristics for evaluating electronic health record (EHR) alerts and linked ordering support by integrating them with Dual Process theory. Through initial heuristic evaluation and a user study of 7 physicians, usability problems were identified. Through independent mapping of specific usability criteria to support for each of the Dual Cognitive processes (S1 and S2) and deliberation, agreement was reached on mapping criteria. Finally, usability errors from the heuristic and user study were mapped to S1 and S2. Adding a dual process perspective to specific heuristic analysis increases the applicability and relevance of computerized health information design evaluations. This mapping enables designers to measure that their systems are tailored to support attention allocation. System 1 will be supported by improving pattern recognition and saliency, and system 2 through efficiency and control of information access. PMID:28269915

  1. Adapting Nielsen's Design Heuristics to Dual Processing for Clinical Decision Support.

    PubMed

    Taft, Teresa; Staes, Catherine; Slager, Stacey; Weir, Charlene

    2016-01-01

    The study objective was to improve the applicability of Nielson's standard design heuristics for evaluating electronic health record (EHR) alerts and linked ordering support by integrating them with Dual Process theory. Through initial heuristic evaluation and a user study of 7 physicians, usability problems were identified. Through independent mapping of specific usability criteria to support for each of the Dual Cognitive processes (S1 and S2) and deliberation, agreement was reached on mapping criteria. Finally, usability errors from the heuristic and user study were mapped to S1 and S2. Adding a dual process perspective to specific heuristic analysis increases the applicability and relevance of computerized health information design evaluations. This mapping enables designers to measure that their systems are tailored to support attention allocation. System 1 will be supported by improving pattern recognition and saliency, and system 2 through efficiency and control of information access.

  2. Validity of peer grading using Calibrated Peer Review in a guided-inquiry, conceptual physics course

    NASA Astrophysics Data System (ADS)

    Price, Edward; Goldberg, Fred; Robinson, Steve; McKean, Michael

    2016-12-01

    Constructing and evaluating explanations are important science practices, but in large classes it can be difficult to effectively engage students in these practices and provide feedback. Peer review and grading are scalable instructional approaches that address these concerns, but which raise questions about the validity of the peer grading process. Calibrated Peer Review (CPR) is a web-based system that scaffolds peer evaluation through a "calibration" process where students evaluate sample responses and receive feedback on their evaluations before evaluating their peers. Guided by an activity theory framework, we developed, implemented, and evaluated CPR-based tasks in guided-inquiry, conceptual physics courses for future teachers and general education students. The tasks were developed through iterative testing and revision. Effective tasks had specific and directed prompts and evaluation instructions. Using these tasks, over 350 students at three universities constructed explanations or analyzed physical phenomena, and evaluated their peers' work. By independently assessing students' responses, we evaluated the CPR calibration process and compared students' peer reviews with expert evaluations. On the tasks analyzed, peer scores were equivalent to our independent evaluations. On a written explanation item included on the final exam, students in the courses using CPR outperformed students in similar courses using traditional writing assignments without a peer evaluation element. Our research demonstrates that CPR can be an effective way to explicitly include the science practices of constructing and evaluating explanations into large classes without placing a significant burden on the instructor.

  3. 78 FR 32244 - Combined Notice of Filings #1

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-29

    .... Applicants: Midcontinent Independent System Operator, Inc. Description: Midcontinent Independent System.... Applicants: Midcontinent Independent System Operator, Inc. Description: Midcontinent Independent System... Company submits: Interconnection Agreement Between MECO and French River Land Co. re Tannery Pond to be...

  4. [Integral quantitative evaluation of working conditions in the construction industry].

    PubMed

    Guseĭnov, A A

    1993-01-01

    Present method evaluating the quality of environment (using MAC and MAL) does not enable to assess completely and objectively the work conditions of building industry due to multiple confounding elements. A solution to this complicated problem including the analysis of various correlating elements of the system "human--work conditions--environment" may be encouraged by social norm of morbidity, which is independent on industrial and natural environment. The complete integral assessment enables to see the whole situation and reveal the points at risk.

  5. Preliminary Evaluation of a Personal Healthcare System Prototype for Cognitive eRehabilitation in a Living Assistance Domain

    PubMed Central

    Pastorino, Matteo; Fioravanti, Alessio; Arredondo, Maria Teresa; Cogollor, José M.; Rojo, Javier; Ferre, Manuel; Bienkiewicz, Marta; Hermsdörfer, Joachim; Fringi, Evangelia; Wing, Alan M.

    2014-01-01

    The integration of rehabilitation systems in an ambient assisted living environment can provide a powerful and versatile tool for long-term stroke rehabilitation goals. This paper introduces a novel concept of a personalized cognitive rehabilitation system in a naturalistic setting. The proposed platform was developed within the CogWatch project, with the intent of fostering independence in activities of daily living in patients with apraxia and action disorganization syndrome. Technical usability was evaluated in a series of pilot experiments, which illustrate how this approach may help to retrain patients in activities of daily living. The first system prototype has been tested with 36 participants divided into three groups, providing an exploratory evaluation of the usability of this solution and its acceptability. The technical solutions used within the CogWatch project are targeted to meet both the end users' needs from the interaction and usability point of views and the clinical requirements associated with the use of such systems. The challenges behind the development of ambient assisted living systems for cognitive rehabilitation are discussed. PMID:24922452

  6. Implementing hospital quality assurance policies in Iran: balancing licensing, annual evaluation, inspections and quality management systems.

    PubMed

    Aghaei Hashjin, Asgar; Delgoshaei, Bahram; Kringos, Dionne S; Tabibi, Seyed Jamaladin; Manouchehri, Jila; Klazinga, Niek S

    2015-01-01

    The purpose of this paper is to provide an overview of applied hospital quality assurance (QA) policies in Iran. A mixed method (quantitative data and qualitative document analysis) study was carried out between 1996 and 2010. The QA policy cycle forms a tight monitoring system to assure hospital quality by combining mandatory and voluntary methods in Iran. The licensing, annual evaluation and grading, and regulatory inspections statutorily implemented by the government as a national package to assure and improve hospital care quality, while implementing quality management systems (QMS) was voluntary for hospitals. The government's strong QA policy legislation role and support has been an important factor for successful QA implementation in Iran, though it may affected QA assessment independency and validity. Increased hospital evaluation independency and repositioning, updating standards, professional involvement and effectiveness studies could increase QA policy impact and maturity. The study highlights the current QA policy implementation cycle in Iranian hospitals. It provides a basis for further quality strategy development in Iranian hospitals and elsewhere. It also raises attention about finding the optimal balance between different QA policies, which is topical for many countries. This paper describes experiences when implementing a unique approach, combining mandatory and voluntary QA policies simultaneously in a developing country, which has invested considerably over time to improve hospital quality. The experiences with a mixed obligatory/voluntary approach and comprehensive policies in Iran may contain lessons for policy makers in developing and developed countries.

  7. Cargo Fire Hazards and Hazard Control for the Offshore Bulk Fuel Systems (OBFS).

    DTIC Science & Technology

    1980-06-01

    used to evaluate the probability of cargo fuel spills during different ship operational modes. An undesired hazardous event such as a spill of volume...occur. if a cargo release occurs due to either collision or hostile action the probability of ignition is very high . Ignition can be caused by the...Separate auxiliary burners independent from the ship propulsion system provide similar flue gas composition. However as noted previously, a low sulfur

  8. Common sense about taste: from mammals to insects.

    PubMed

    Yarmolinsky, David A; Zuker, Charles S; Ryba, Nicholas J P

    2009-10-16

    The sense of taste is a specialized chemosensory system dedicated to the evaluation of food and drink. Despite the fact that vertebrates and insects have independently evolved distinct anatomic and molecular pathways for taste sensation, there are clear parallels in the organization and coding logic between the two systems. There is now persuasive evidence that tastant quality is mediated by labeled lines, whereby distinct and strictly segregated populations of taste receptor cells encode each of the taste qualities.

  9. Milwaukee Independent Charter Schools Study: Report on One Year of Student Growth. SCDP Milwaukee Evaluation. Report # 21--Version 1.1

    ERIC Educational Resources Information Center

    Witte, John F.; Wolf, Patrick J.; Dean, Alicia; Carlson, Deven

    2010-01-01

    The general purpose of this evaluation is to assess the effectiveness of independent charter schools in promoting two desirable student outcomes: student achievement growth and educational attainment. Independent charter schools are authorized by non-district entities and are considered "independent" because they are not a part of the…

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartoletti, T.

    SPI/U3.1 consists of five tools used to assess and report the security posture of computers running the UNIX operating system. The tools are: Access Control Test: A rule-based system which identifies sequential dependencies in UNIX access controls. Binary Inspector Tool: Evaluates the release status of system binaries by comparing a crypto-checksum to provide table entries. Change Detection Tool: Maintains and applies a snapshot of critical system files and attributes for purposes of change detection. Configuration Query Language: Accepts CQL-based scripts (provided) to evaluate queries over the status of system files, configuration of services and many other elements of UNIX systemmore » security. Password Security Inspector: Tests for weak or aged passwords. The tools are packaged with a forms-based user interface providing on-line context-sensistive help, job scheduling, parameter management and output report management utilities. Tools may be run independent of the UI.« less

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartoletti, Tony

    SPI/U3.2 consists of five tools used to assess and report the security posture of computers running the UNIX operating system. The tools are: Access Control Test: A rule-based system which identifies sequential dependencies in UNIX access controls. Binary Authentication Tool: Evaluates the release status of system binaries by comparing a crypto-checksum to provide table entries. Change Detection Tool: Maintains and applies a snapshot of critical system files and attributes for purposes of change detection. Configuration Query Language: Accepts CQL-based scripts (provided) to evaluate queries over the status of system files, configuration of services and many other elements of UNIX systemmore » security. Password Security Inspector: Tests for weak or aged passwords. The tools are packaged with a forms-based user interface providing on-line context-sensistive help, job scheduling, parameter management and output report management utilities. Tools may be run independent of the UI.« less

  12. PRACA Enhancement Pilot Study Report: Engineering for Complex Systems Program (formerly Design for Safety), DFS-IC-0006

    NASA Technical Reports Server (NTRS)

    Korsmeyer, David; Schreiner, John

    2002-01-01

    This technology evaluation report documents the findings and recommendations of the Engineering for Complex Systems Program (formerly Design for Safety) PRACA Enhancement Pilot Study of the Space Shuttle Program's (SSP's) Problem Reporting and Corrective Action (PRACA) System. A team at NASA Ames Research Center (ARC) performed this Study. This Study was initiated as a follow-on to the NASA chartered Shuttle Independent Assessment Team (SIAT) review (performed in the Fall of 1999) which identified deficiencies in the current PRACA implementation. The Pilot Study was launched with an initial qualitative assessment and technical review performed during January 2000 with the quantitative formal Study (the subject of this report) started in March 2000. The goal of the PRACA Enhancement Pilot Study is to evaluate and quantify the technical aspects of the SSP PRACA systems and recommend enhancements to address deficiencies and in preparation for future system upgrades.

  13. An automated method for the evaluation of the pointing accuracy of Sun-tracking devices

    NASA Astrophysics Data System (ADS)

    Baumgartner, Dietmar J.; Pötzi, Werner; Freislich, Heinrich; Strutzmann, Heinz; Veronig, Astrid M.; Rieder, Harald E.

    2017-03-01

    The accuracy of solar radiation measurements, for direct (DIR) and diffuse (DIF) radiation, depends significantly on the precision of the operational Sun-tracking device. Thus, rigid targets for instrument performance and operation have been specified for international monitoring networks, e.g., the Baseline Surface Radiation Network (BSRN) operating under the auspices of the World Climate Research Program (WCRP). Sun-tracking devices that fulfill these accuracy requirements are available from various instrument manufacturers; however, none of the commercially available systems comprise an automatic accuracy control system allowing platform operators to independently validate the pointing accuracy of Sun-tracking sensors during operation. Here we present KSO-STREAMS (KSO-SunTRackEr Accuracy Monitoring System), a fully automated, system-independent, and cost-effective system for evaluating the pointing accuracy of Sun-tracking devices. We detail the monitoring system setup, its design and specifications, and the results from its application to the Sun-tracking system operated at the Kanzelhöhe Observatory (KSO) Austrian radiation monitoring network (ARAD) site. The results from an evaluation campaign from March to June 2015 show that the tracking accuracy of the device operated at KSO lies within BSRN specifications (i.e., 0.1° tracking accuracy) for the vast majority of observations (99.8 %). The evaluation of manufacturer-specified active-tracking accuracies (0.02°), during periods with direct solar radiation exceeding 300 W m-2, shows that these are satisfied in 72.9 % of observations. Tracking accuracies are highest during clear-sky conditions and on days where prevailing clear-sky conditions are interrupted by frontal movement; in these cases, we obtain the complete fulfillment of BSRN requirements and 76.4 % of observations within manufacturer-specified active-tracking accuracies. Limitations to tracking surveillance arise during overcast conditions and periods of partial solar-limb coverage by clouds. On days with variable cloud cover, 78.1 % (99.9 %) of observations meet active-tracking (BSRN) accuracy requirements while for days with prevailing overcast conditions these numbers reduce to 64.3 % (99.5 %).

  14. Evaluation of the FORETELL consortium operational test : weather information for surface transportation, evaluation strategy

    DOT National Transportation Integrated Search

    1998-07-01

    The purpose of the independent evaluation is to assess the effectiveness of the FORETELL Program in achieving certain ARTS goals and objectives. Independent evaluations of ITS Operational Tests require a well documented structured approach to ensure ...

  15. [Role of medium-sized independent laboratories in control of healthcare-associated infection].

    PubMed

    Anzai, Eiko; Fukui, Toru

    2009-05-01

    In 2006, the Ministry of Health and Welfare revised the regulations regarding the Medical Service Law. The amendments stipulate that all healthcare institutions are required to implement infection control programs. However, small hospitals and clinics have no clinical microbiology laboratories, whereas medium-sized hospitals have few medical technologists and the outsourcing of microbiology tests to independent laboratories is common. The decreasing number of laboratories and recent outsourcing tendency reflect the increasing commercialization, and, with it, the escalating number of commercially operating chains. Each independent laboratory is responsible for supporting activities related to the surveillance, control, and prevention of healthcare-associated infections in the associated small and medium-sized hospitals. The people responsible for infection control in these hospitals usually do not have a background in microbiology. The evaluation of communication between independent laboratory staff and hospital personnel, and rapid turnaround time of microbiology laboratory test reports are important elements ensuring the quality of independent laboratory work. With the pressures of financial constraints in the Japanese medical insurance system, the development of a cost-effective and practical protocol for quality assurance is a real dilemma.

  16. [(Dis)satisfaction with the municipal infrastructure. How do senior citizens evaluate their living conditions?].

    PubMed

    Piorkowsky, M-B

    2010-04-01

    In order to evaluate the perceived living conditions, i.e., satisfaction with the scope and quality of municipal infrastructure, from a senior citizen's perspective, a questionnaire, differentiating six areas and 39 sub-areas and the corresponding testing scales for satisfaction with the quality of life, was developed analogous to the grading system used in the German school system. This questionnaire is suitable for evaluative city walks and comparative analyses of the municipal infrastructure to gain indications of the quality and to identify or shape future infrastructure actions. In 2007/2008, the questionnaire was used by the local senior citizen's representatives in the federal states of Germany. The data obtained were condensed into indices of citizen satisfaction and factor analysis was performed. As a result, the 39 sub-areas could be reduced to 11 independent dimensions, which disclose general patterns of perceiving and evaluating the quality of municipal life.

  17. Two Persons with Multiple Disabilities Use Orientation Technology with Auditory Cues to Manage Simple Indoor Traveling

    ERIC Educational Resources Information Center

    Lancioni, Giulio E.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Campodonico, Francesca; Oliva, Doretta

    2010-01-01

    This study was an effort to extend the evaluation of orientation technology for promoting independent indoor traveling in persons with multiple disabilities. Two participants (adults) were included, who were to travel to activity destinations within occupational settings. The orientation system involved (a) cueing sources only at the destinations…

  18. ""Moby-Dick" Is My Favorite:" Evaluating a Cognitively Accessible Portable Reading System for Audiobooks for Individuals with Intellectual Disability

    ERIC Educational Resources Information Center

    Davies, Daniel K.; Stock, Steven E.; King, Larry R.; Wehmeyer, Michael L.

    2008-01-01

    Significant barriers exist for individuals with intellectual disability to independently access print-based content. It is regrettable that, while the amount of content now available electronically increases, tools to access these materials have not been developed with individuals with intellectual disability in mind. This article reports the…

  19. Operation Prime Program (Central Junior High School), Title I Evaluation, 1973-76.

    ERIC Educational Resources Information Center

    Granite School District, Salt Lake City, UT.

    This document consists of reports (for the 1973-1974, 1974-1975, and 1975-1976 school years) of an individualized reading and math program designed for secondary school students functioning below their grade level. The program involves a management system using flow charts, independent study, student motivation provided by free time in a…

  20. Promoting Independence through Assistive Technology: Evaluating Audio Recorders to Support Grocery Shopping

    ERIC Educational Resources Information Center

    Bouck, Emily C.; Satsangi, Rajiv; Bartlett, Whitney; Weng, Pei-Lin

    2012-01-01

    In light of a positive research base regarding technology-based self-operating prompting systems (e.g., iPods), yet a concern about the sustainability of such technologies after a research project is completed, this study sought to explore the effectiveness and efficiency of an audio recorder, a low-cost, more commonly accessible technology to…

  1. Academic Staff Views on External Quality Audit: Post Audit Evaluation in a Private Higher Education College

    ERIC Educational Resources Information Center

    Shah, Mahsood; Nair, Chenicheri Sid; Stanford, Sue-Ann

    2011-01-01

    Governments in many countries have funded independent agencies to undertake quality audits of higher education institutions. Such agencies ensure that universities and other higher education providers have effective systems and processes to assure quality assurance in core and support areas. While external quality audits have been in place for a…

  2. Incidence of cervical human papillomavirus infection in systemic lupus erythematosus women.

    PubMed

    Mendoza-Pinto, C; García-Carrasco, M; Vallejo-Ruiz, V; Méndez-Martínez, S; Taboada-Cole, A; Etchegaray-Morales, I; Muñóz-Guarneros, M; Reyes-Leyva, J; López-Colombo, A

    2017-08-01

    Objectives Our objective was to study the incidence, persistence and clearance of human papillomavirus infection in systemic lupus erythematosus women and assess risk factors for persistence of human papillomavirus infection. Methods We carried out a prospective, observational cohort study of 127 systemic lupus erythematosus women. Patients were evaluated at baseline and at three years. Traditional and systemic lupus erythematosus women-related disease risk factors were collected. Gynaecological evaluations and cervical cytology screening were made. Human papillomavirus detection and genotyping were made by polymerase chain reaction and linear array. Results The cumulative prevalence of human papillomavirus infection increased from 22.8% at baseline to 33.8% at three years; p = < 0.001: 20.1% of patients experienced 43 incident infections. The risk of any human papillomavirus infection was 10.1 per 1000 patient-months. At three years, 47 (88.6%) prevalent infections were cleared. Independent risk factors associated with incident human papillomavirus infection included more lifetime sexual partners (odds ratio = 1.8, 95% confidence interval = 1.11-3.0) and cumulative cyclophosphamide dose (odds ratio = 3.9, 95% confidence interval = 1.2-12.8). Conclusions In systemic lupus erythematosus women, the cumulative prevalence of human papillomavirus infection, including high risk-human papillomavirus and multiple human papillomavirus infections, may increase over time. Most persistent infections were low risk-human papillomavirus. The number of lifetime sexual partners and the cumulative cyclophosphamide dose were independently associated with incident human papillomavirus infection.

  3. A tutorial on the use of ROC analysis for computer-aided diagnostic systems.

    PubMed

    Scheipers, Ulrich; Perrey, Christian; Siebers, Stefan; Hansen, Christian; Ermert, Helmut

    2005-07-01

    The application of the receiver operating characteristic (ROC) curve for computer-aided diagnostic systems is reviewed. A statistical framework is presented and different methods of evaluating the classification performance of computer-aided diagnostic systems, and, in particular, systems for ultrasonic tissue characterization, are derived. Most classifiers that are used today are dependent on a separation threshold, which can be chosen freely in many cases. The separation threshold separates the range of output values of the classification system into different target groups, thus conducting the actual classification process. In the first part of this paper, threshold specific performance measures, e.g., sensitivity and specificity, are presented. In the second part, a threshold-independent performance measure, the area under the ROC curve, is reviewed. Only the use of separation threshold-independent performance measures provides classification results that are overall representative for computer-aided diagnostic systems. The following text was motivated by the lack of a complete and definite discussion of the underlying subject in available textbooks, references and publications. Most manuscripts published so far address the theme of performance evaluation using ROC analysis in a manner too general to be practical for everyday use in the development of computer-aided diagnostic systems. Nowadays, the user of computer-aided diagnostic systems typically handles huge amounts of numerical data, not always distributed normally. Many assumptions made in more or less theoretical works on ROC analysis are no longer valid for real-life data. The paper aims at closing the gap between theoretical works and real-life data. The review provides the interested scientist with information needed to conduct ROC analysis and to integrate algorithms performing ROC analysis into classification systems while understanding the basic principles of classification.

  4. Independent Analysis of Real-Time, Measured Performance Data From Microcogenerative Fuel Cell Systems Installed in Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dillon, Heather E.; Colella, Whitney G.

    2015-06-01

    Pacific Northwest National Laboratory (PNNL) is working with industry to independently monitor up to 15 distinct 5 kW-electric (kWe) combined heat and power (CHP) high temperature (HT) proton exchange membrane (PEM) fuel cell systems (FCSs) installed in light commercial buildings. This research paper discusses an evaluation of the first six months of measured performance data acquired at a 1 s sampling rate from real-time monitoring equipment attached to the FCSs at building sites. Engineering performance parameters are independently evaluated. Based on an analysis of the first few months of measured operating data, FCS performance is consistent with manufacturer-stated performance. Initialmore » data indicate that the FCSs have relatively stable performance and a long-term average production of about 4.57 kWe of power. This value is consistent with, but slightly below, the manufacturer's stated rated electric power output of 5 kWe. The measured system net electric efficiency has averaged 33.7%, based on the higher heating value (HHV) of natural gas fuel. This value, also, is consistent with, but slightly below, the manufacturer's stated rated electric efficiency of 36%. The FCSs provide low-grade hot water to the building at a measured average temperature of about 48.4 degrees C, lower than the manufacturer's stated maximum hot water delivery temperature of 65 degrees C. The uptime of the systems is also evaluated. System availability can be defined as the quotient of total operating time compared to time since commissioning. The average values for system availability vary between 96.1 and 97.3%, depending on the FCS evaluated in the field. Performance at rated value for electrical efficiency (PRVeff) can be defined as the quotient of the system time operating at or above the rated electric efficiency and the time since commissioning. The PRVeff varies between 5.6% and 31.6%, depending on the FCS field unit evaluated. Performance at rated value for electrical power (PRVp) can be defined as the quotient of the system time operating at or above the rated electric power and the time since commissioning. PRVp varies between 6.5% and 16.2%. Performance at rated value for electrical efficiency and power (PRVt) can be defined as the quotient of the system time operating at or above both the rated electric efficiency and the electric power output compared to the time since commissioning. PRVt varies between 0.2% and 1.4%. Optimization to determine the manufacturer rating required to achieve PRVt greater than 80% has been performed based on the collected data. For example, for FCS Unit 130 to achieve a PRVt of 95%, it would have to be down-rated to an electrical power output of 3.2 kWe and an electrical efficiency of 29%. The use of PRV as an assessment metric for FCSs has been developed and reported for the first time in this paper. For FCS Unit 130, a maximum decline in electric power output of approximately 18% was observed over a 500 h period in Jan. 2012.« less

  5. Single isotope fractionation of (16)O(-) implications for early history of solar system

    NASA Technical Reports Server (NTRS)

    Arrhenius, G.

    1980-01-01

    Chemical fractionation processes are investigated with emphasis on selective single isotope fractionation in polyisotopic systems, particularly in oxygen. The related temperature parameters of meteoritic condensates and of their source medium are investigated by a thermometric method that is independent of assumptions regarding temperatures and pressures in the solar nebula. The crucial nonlinear chemical fractionation of O-16 was demonstrated experimentally. The effect was achieved in condensed CO2 formed from CO with C-12 O-16 selectively excited by H Ly alpha. The effect was verified by mass spectrometric measurements. The meteorite paleotemperature estimates were advanced from defining only thermal exposure to evaluating time and temperature independently. Grain temperatures at condensation of refractory inclusion materials are indicated to be less than 900 K in agreement with radiation temperature considerations and observations in circumstellar dust shells.

  6. Evaluative reports on medical malpractice policies in obstetrics: a rapid scoping review.

    PubMed

    Cardoso, Roberta; Zarin, Wasifa; Nincic, Vera; Barber, Sarah Louise; Gulmezoglu, Ahmet Metin; Wilson, Charlotte; Wilson, Katherine; McDonald, Heather; Kenny, Meghan; Warren, Rachel; Straus, Sharon E; Tricco, Andrea C

    2017-09-06

    The clinical specialty of obstetrics is under particular scrutiny with increasing litigation costs and unnecessary tests and procedures done in attempts to prevent litigation. We aimed to identify reports evaluating or comparing the effectiveness of medical liability reforms and quality improvement strategies in improving litigation-related outcomes in obstetrics. We conducted a rapid scoping review with a 6-week timeline. MEDLINE, EMBASE, LexisNexis Academic, the Legal Scholarship Network, Justis, LegalTrac, QuickLaw, and HeinOnline were searched for publications in English from 2004 until June 2015. The selection criteria for screening were established a priori and pilot-tested. We included reports comparing or evaluating the impact of obstetrics-related medical liability reforms and quality improvement strategies on cost containment and litigation settlement across all countries. All levels of screening were done by two reviewers independently, and discrepancies were resolved by a third reviewer. In addition, two reviewers independently extracted relevant data using a pre-tested form, and discrepancies were resolved by a third reviewer. The results were summarized descriptively. The search resulted in 2729 citations, of which 14 reports met our eligibility criteria. Several initiatives for improving the medical malpractice litigation system were found, including no-fault approaches, patient safety policy initiatives, communication and resolution, caps on compensation and attorney fees, alternative payment system and liabilities, and limitations on litigation. Only a few litigation policies in obstetrics were evaluated or compared. Included documents showed that initiatives to reduce medical malpractice litigation could be associated with a decrease in adverse and malpractice events. However, due to heterogeneous settings (e.g., economic structure, healthcare system) and variation in the outcomes reported, the advantages and disadvantages of initiatives may vary.

  7. Independent Orbiter Assessment (IOA): Analysis of the electrical power distribution and control/remote manipulator system subsystem

    NASA Technical Reports Server (NTRS)

    Robinson, W. W.

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the Electrical Power Distribution and Control (EPD and C)/Remote Manipulator System (RMS) hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained in the NASA FMEA/CIL documentation. This report documents the results of the independent analysis of the EPD and C/RMS (both port and starboard) hardware. The EPD and C/RMS subsystem hardware provides the electrical power and power control circuitry required to safely deploy, operate, control, and stow or guillotine and jettison two (one port and one starboard) RMSs. The EPD and C/RMS subsystem is subdivided into the four following functional divisions: Remote Manipulator Arm; Manipulator Deploy Control; Manipulator Latch Control; Manipulator Arm Shoulder Jettison; and Retention Arm Jettison. The IOA analysis process utilized available EPD and C/RMS hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based on the severity of the effect for each failure mode.

  8. Independent Orbiter Assessment (IOA): Analysis of the elevon subsystem

    NASA Technical Reports Server (NTRS)

    Wilson, R. E.; Riccio, J. R.

    1986-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results for the Orbiter Elevon system hardware. The elevon actuators are located at the trailing edge of the wing surface. The proper function of the elevons is essential during the dynamic flight phases of ascent and entry. In the ascent phase of flight, the elevons are used for relieving high wing loads. For entry, the elevons are used to pitch and roll the vehicle. Specifically, the elevon system hardware comprises the following components: flow cutoff valve; switching valve; electro-hydraulic (EH) servoactuator; secondary delta pressure transducer; bypass valve; power valve; power valve check valve; primary actuator; primary delta pressure transducer; and primary actuator position transducer. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 25 failure modes analyzed, 18 were determined to be PCIs.

  9. Initial fractal exponent of heart-rate variability is associated with success of early resuscitation in patients with severe sepsis or septic shock: a prospective cohort study

    PubMed Central

    Brown, Samuel M.; Tate, Quinn; Jones, Jason P.; Knox, Daniel; Kuttler, Kathryn G.; Lanspa, Michael; Rondina, Matthew T.; Grissom, Colin K.; Behera, Subhasis; Mathews, V.J.; Morris, Alan

    2013-01-01

    Introduction Heart-rate variability reflects autonomic nervous system tone as well as the overall health of the baroreflex system. We hypothesized that loss of complexity in heart-rate variability upon ICU admission would be associated with unsuccessful early resuscitation of sepsis. Methods We prospectively enrolled patients admitted to ICUs with severe sepsis or septic shock from 2009 to 2011. We studied 30 minutes of EKG, sampled at 500 Hz, at ICU admission and calculated heart-rate complexity via detrended fluctuation analysis. Primary outcome was vasopressor independence at 24 hours after ICU admission. Secondary outcome was 28-day mortality. Results We studied 48 patients, of whom 60% were vasopressor independent at 24 hours. Five (10%) died within 28 days. The ratio of fractal alpha parameters was associated with both vasopressor independence and 28-day mortality (p=0.04) after controlling for mean heart rate. In the optimal model, SOFA score and the long-term fractal alpha parameter were associated with vasopressor independence. Conclusions Loss of complexity in heart rate variability is associated with worse outcome early in severe sepsis and septic shock. Further work should evaluate whether complexity of heart rate variability (HRV) could guide treatment in sepsis. PMID:23958243

  10. Independent Orbiter Assessment (IOA): Analysis of the mechanical actuation subsystem

    NASA Technical Reports Server (NTRS)

    Bacher, J. L.; Montgomery, A. D.; Bradway, M. W.; Slaughter, W. T.

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Mechanical Actuation System (MAS) hardware. Specifically, the MAS hardware consists of the following components: Air Data Probe (ADP); Elevon Seal Panel (ESP); External Tank Umbilical (ETU); Ku-Band Deploy (KBD); Payload Bay Doors (PBD); Payload Bay Radiators (PBR); Personnel Hatches (PH); Vent Door Mechanism (VDM); and Startracker Door Mechanism (SDM). The IOA analysis process utilized available MAS hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.

  11. An autonomous mobile system for the management of COPD.

    PubMed

    van der Heijden, Maarten; Lucas, Peter J F; Lijnse, Bas; Heijdra, Yvonne F; Schermer, Tjard R J

    2013-06-01

    Managing chronic disease through automated systems has the potential to both benefit the patient and reduce health-care costs. We have developed and evaluated a disease management system for patients with chronic obstructive pulmonary disease (COPD). Its aim is to predict and detect exacerbations and, through this, help patients self-manage their disease to prevent hospitalisation. The carefully crafted intelligent system consists of a mobile device that is able to collect case-specific, subjective and objective, physiological data, and to alert the patient by a patient-specific interpretation of the data by means of probabilistic reasoning. Collected data are also sent to a central server for inspection by health-care professionals. We evaluated the probabilistic model using cross-validation and ROC analyses on data from an earlier study and by an independent data set. Furthermore a pilot with actual COPD patients has been conducted to test technical feasibility and to obtain user feedback. Model evaluation results show that we can reliably detect exacerbations. Pilot study results suggest that an intervention based on this system could be successful. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Assessment of the quality of cervical mucus among users of the levonorgestrel-releasing intrauterine system at different times of use.

    PubMed

    Moraes, Leticia G; Marchi, Nadia M; Pitoli, Ana C; Hidalgo, Maria M; Silveira, Carolina; Modesto, Waleska; Bahamondes, Luis

    2016-08-01

    The quality of cervical mucus (CM) among the levonorgestrel-releasing intrauterine system (LNG-IUS) users is controversial. The objectives were to assess CM compared to the levels of oestradiol (E2) and the frequency of cycles with luteal activity among users of the LNG-IUS. In total, 224 LNG-IUS users for between two months and five years were recruited at a Brazilian family planning clinic. For the cross-sectional part of the study, we enrolled 175 LNG-IUS users at 2, 6 12, 24, 36, 48, and 60 months after insertion (25 women in each group), and we performed one evaluation. For the prospective part of the study, we enrolled 49 LNG-IUS users at the same lengths of use after insertion (7 women in each group), and we evaluated these women once a week for five consecutive weeks. . Mean (± SEM) CM scores of all evaluations among women with single and weekly evaluations were between 3.3 ± 0.9 and 8.5 ± 0.3, respectively independently of the length of use of the LNG-IUS. Mean E2 values ranged from 45.5 ± 6.8 to 472.5 ± 34.7 pg/ml and the maximum ovarian follicle diameter on the days of evaluation varied from 14.0 ± 1.3 to 31.2 ± 0.4 mm. The mean CM score of all evaluations, independent of the length of use of the LNG-IUS and normal levels of serum E2, was below 10 was according to the WHO is inadequate for sperm penetration.

  13. Collaborative Relationships in Evaluation Consulting

    ERIC Educational Resources Information Center

    Maack, Stephen C.; Upton, Jan

    2006-01-01

    People are often driven to become "independent" as part of the desire to go out on their own. Independent evaluation consultants, however, frequently collaborate with others on evaluation projects. This chapter explores such collaborative relationships from both sides: those leading evaluations with subcontracted consultants and those who work as…

  14. Inter- and intra-observer agreement of BI-RADS-based subjective visual estimation of amount of fibroglandular breast tissue with magnetic resonance imaging: comparison to automated quantitative assessment.

    PubMed

    Wengert, G J; Helbich, T H; Woitek, R; Kapetas, P; Clauser, P; Baltzer, P A; Vogl, W-D; Weber, M; Meyer-Baese, A; Pinker, Katja

    2016-11-01

    To evaluate the inter-/intra-observer agreement of BI-RADS-based subjective visual estimation of the amount of fibroglandular tissue (FGT) with magnetic resonance imaging (MRI), and to investigate whether FGT assessment benefits from an automated, observer-independent, quantitative MRI measurement by comparing both approaches. Eighty women with no imaging abnormalities (BI-RADS 1 and 2) were included in this institutional review board (IRB)-approved prospective study. All women underwent un-enhanced breast MRI. Four radiologists independently assessed FGT with MRI by subjective visual estimation according to BI-RADS. Automated observer-independent quantitative measurement of FGT with MRI was performed using a previously described measurement system. Inter-/intra-observer agreements of qualitative and quantitative FGT measurements were assessed using Cohen's kappa (k). Inexperienced readers achieved moderate inter-/intra-observer agreement and experienced readers a substantial inter- and perfect intra-observer agreement for subjective visual estimation of FGT. Practice and experience reduced observer-dependency. Automated observer-independent quantitative measurement of FGT was successfully performed and revealed only fair to moderate agreement (k = 0.209-0.497) with subjective visual estimations of FGT. Subjective visual estimation of FGT with MRI shows moderate intra-/inter-observer agreement, which can be improved by practice and experience. Automated observer-independent quantitative measurements of FGT are necessary to allow a standardized risk evaluation. • Subjective FGT estimation with MRI shows moderate intra-/inter-observer agreement in inexperienced readers. • Inter-observer agreement can be improved by practice and experience. • Automated observer-independent quantitative measurements can provide reliable and standardized assessment of FGT with MRI.

  15. An automated method for the evaluation of the pointing accuracy of sun-tracking devices

    NASA Astrophysics Data System (ADS)

    Baumgartner, Dietmar J.; Rieder, Harald E.; Pötzi, Werner; Freislich, Heinrich; Strutzmann, Heinz

    2016-04-01

    The accuracy of measurements of solar radiation (direct and diffuse radiation) depends significantly on the accuracy of the operational sun-tracking device. Thus rigid targets for instrument performance and operation are specified for international monitoring networks, such as e.g., the Baseline Surface Radiation Network (BSRN) operating under the auspices of the World Climate Research Program (WCRP). Sun-tracking devices fulfilling these accuracy targets are available from various instrument manufacturers, however none of the commercially available systems comprises a secondary accuracy control system, allowing platform operators to independently validate the pointing accuracy of sun-tracking sensors during operation. Here we present KSO-STREAMS (KSO-SunTRackEr Accuracy Monitoring System), a fully automated, system independent and cost-effective method for evaluating the pointing accuracy of sun-tracking devices. We detail the monitoring system setup, its design and specifications and results from its application to the sun-tracking system operated at the Austrian RADiation network (ARAD) site Kanzelhöhe Observatory (KSO). Results from KSO-STREAMS (for mid-March to mid-June 2015) show that the tracking accuracy of the device operated at KSO lies well within BSRN specifications (i.e. 0.1 degree accuracy). We contrast results during clear-sky and partly cloudy conditions documenting sun-tracking performance at manufacturer specified accuracies for active tracking (0.02 degrees) and highlight accuracies achieved during passive tracking i.e. periods with less than 300 W m-2 direct radiation. Furthermore we detail limitations to tracking surveillance during overcast conditions and periods of partial solar limb coverage by clouds.

  16. Common Sense about Taste: From Mammals to Insects

    PubMed Central

    Yarmolinsky, David A.; Zuker, Charles S.; Ryba, Nicholas J.P.

    2013-01-01

    The sense of taste is a specialized chemosensory system dedicated to the evaluation of food and drink. Despite the fact that vertebrates and insects have independently evolved distinct anatomic and molecular pathways for taste sensation, there are clear parallels in the organization and coding logic between the two systems. There is now persuasive evidence that tastant quality is mediated by labeled lines, whereby distinct and strictly segregated populations of taste receptor cells encode each of the taste qualities. PMID:19837029

  17. VLBI Digital-Backend Intercomparison Test Report

    NASA Technical Reports Server (NTRS)

    Whitney, Alan; Beaudoin, Christopher; Cappallo, Roger; Niell, Arthur; Petrachenko, Bill; Ruszczyk, Chester A.; Titus, Mike

    2013-01-01

    Issues related to digital-backend (DBE) systems can be difficult to evaluate in either local tests or actual VLBI experiments. The 2nd DBE intercomparison workshop at Haystack Observatory on 25-26 October 2012 provided a forum to explicitly address validation and interoperability issues among independent global developers of DBE equipment. This special report discusses the workshop. It identifies DBE systems that were tested at the workshop, describes the test objectives and procedures, and reports and discusses the results of the testing.

  18. MONO FOR CROSS-PLATFORM CONTROL SYSTEM ENVIRONMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nishimura, Hiroshi; Timossi, Chris

    2006-10-19

    Mono is an independent implementation of the .NET Frameworkby Novell that runs on multiple operating systems (including Windows,Linux and Macintosh) and allows any .NET compatible application to rununmodified. For instance Mono can run programs with graphical userinterfaces (GUI) developed with the C# language on Windows with VisualStudio (a full port of WinForm for Mono is in progress). We present theresults of tests we performed to evaluate the portability of our controlssystem .NET applications from MS Windows to Linux.

  19. Manufacturing Technology Support (MATES II) Task Order 0005: Manufacturing Integration and Technology Evaluation to Enable Technology Transition. Subtask Phase 0 Study Task: Manufacturing Technology (ManTech) and Systems Engineering For Quick Reaction Systems

    DTIC Science & Technology

    2014-10-01

    Porosity from gas entrapment & shrinkage 4 Continuous Fiber Ti Metal Matrix Composites (Aircraft panels and rotor components) [14...process models for casting, forging, and welding , and software capability to integrate various independent models with design, thermal, and structural...Applications, Ph.D. Thesis, Queen’s College, University of Oxford, (2007). 14. S.A. Singerman and J.J. Jackson, Titanium Metal Matrix Composites for

  20. A Parallel Trade Study Architecture for Design Optimization of Complex Systems

    NASA Technical Reports Server (NTRS)

    Kim, Hongman; Mullins, James; Ragon, Scott; Soremekun, Grant; Sobieszczanski-Sobieski, Jaroslaw

    2005-01-01

    Design of a successful product requires evaluating many design alternatives in a limited design cycle time. This can be achieved through leveraging design space exploration tools and available computing resources on the network. This paper presents a parallel trade study architecture to integrate trade study clients and computing resources on a network using Web services. The parallel trade study solution is demonstrated to accelerate design of experiments, genetic algorithm optimization, and a cost as an independent variable (CAIV) study for a space system application.

  1. A statistical characterization of the Galileo-to-GPS inter-system bias

    NASA Astrophysics Data System (ADS)

    Gioia, Ciro; Borio, Daniele

    2016-11-01

    Global navigation satellite system operates using independent time scales and thus inter-system time offsets have to be determined to enable multi-constellation navigation solutions. GPS/Galileo inter-system bias and drift are evaluated here using different types of receivers: two mass market and two professional receivers. Moreover, three different approaches are considered for the inter-system bias determination: in the first one, the broadcast Galileo to GPS time offset is used to align GPS and Galileo time scales. In the second, the inter-system bias is included in the multi-constellation navigation solution and is estimated using the measurements available. Finally, an enhanced algorithm using constraints on the inter-system bias time evolution is proposed. The inter-system bias estimates obtained with the different approaches are analysed and their stability is experimentally evaluated using the Allan deviation. The impact of the inter-system bias on the position velocity time solution is also considered and the performance of the approaches analysed is evaluated in terms of standard deviation and mean errors for both horizontal and vertical components. From the experiments, it emerges that the inter-system bias is very stable and that the use of constraints, modelling the GPS/Galileo inter-system bias behaviour, significantly improves the performance of multi-constellation navigation.

  2. A provisional effective evaluation when errors are present in independent variables

    NASA Technical Reports Server (NTRS)

    Gurin, L. S.

    1983-01-01

    Algorithms are examined for evaluating the parameters of a regression model when there are errors in the independent variables. The algorithms are fast and the estimates they yield are stable with respect to the correlation of errors and measurements of both the dependent variable and the independent variables.

  3. Research performance evaluation: the experience of an independent medical research institute.

    PubMed

    Schapper, Catherine C; Dwyer, Terence; Tregear, Geoffrey W; Aitken, MaryAnne; Clay, Moira A

    2012-05-01

    Evaluation of the social and economic outcomes of health research funding is an area of intense interest and debate. Typically, approaches have sought to assess the impact of research funding by medical charities or regional government bodies. Independent research institutes have a similar need for accountability in investment decisions but have different objectives and funding, thus the existing approaches are not appropriate. An evaluation methodology using eight indicators was developed to assess research performance across three broad categories: knowledge creation; inputs to research; and commercial, clinical and public health outcomes. The evaluation approach was designed to provide a balanced assessment across laboratory, clinical and public health research. With a diverse research agenda supported by a large number of researchers, the Research Performance Evaluation process at the Murdoch Childrens Research Institute has, by necessity, been iterative and responsive to the needs of the Institute and its staff. Since its inception 5 years ago, data collection systems have been refined, the methodology has been adjusted to capture appropriate data, staff awareness and participation has increased, and issues regarding the methodology and scoring have been resolved. The Research Performance Evaluation methodology described here provides a fair and transparent means of disbursing internal funding. It is also a powerful tool for evaluating the Institute's progress towards achieving its strategic goals, and is therefore a key driver for research excellence.

  4. 77 FR 48565 - Maine Yankee Atomic Power Company, Maine Yankee Independent Spent Fuel Storage Installation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-14

    ... Power Company, Maine Yankee Independent Spent Fuel Storage Installation, Exemption--Staff Evaluation 1.0... in its November 29, 2010, letter. After evaluating the exemption requests, the staff determined that... staff evaluation is documented in a Safety Evaluation Report that contains Sensitive Unclassified Non...

  5. Radiometric Characterization Results for the IKONOS, Quickbird, and OrbView-3 Sensor

    NASA Technical Reports Server (NTRS)

    Holekamp, Kara; Aaron, David; Thome, Kurtis

    2006-01-01

    Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities better understand commercial imaging satellite properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, the NASA Applied Sciences Directorate (ASD) at Stennis Space Center established a commercial satellite imaging radiometric calibration team consisting of three independent groups: NASA ASD, the University of Arizona Remote Sensing Group, and South Dakota State University. Each group independently determined the absolute radiometric calibration coefficients of available high-spatial-resolution commercial 4-band multispectral products, in the visible though near-infrared spectrum, from GeoEye(tradeMark) (formerly SpaceImaging(Registered TradeMark)) IKONOS, DigitalGlobe(Regitered TradeMark) QuickBird, and GeoEye (formerly ORBIMAGE(Registered TradeMark) OrbView. Each team member employed some variant of reflectance-based vicarious calibration approach, requiring ground-based measurements coincident with image acquisitions and radiative transfer calculations. Several study sites throughout the United States that covered a significant portion of the sensor's dynamic range were employed. Satellite at-sensor radiance values were compared to those estimated by each independent team member to evaluate the sensor's radiometric accuracy. The combined results of this evaluation provide the user community with an independent assessment of these sensors' absolute calibration values.

  6. A Flexible Approach for Human Activity Recognition Using Artificial Hydrocarbon Networks

    PubMed Central

    Ponce, Hiram; Miralles-Pechuán, Luis; Martínez-Villaseñor, María de Lourdes

    2016-01-01

    Physical activity recognition based on sensors is a growing area of interest given the great advances in wearable sensors. Applications in various domains are taking advantage of the ease of obtaining data to monitor personal activities and behavior in order to deliver proactive and personalized services. Although many activity recognition systems have been developed for more than two decades, there are still open issues to be tackled with new techniques. We address in this paper one of the main challenges of human activity recognition: Flexibility. Our goal in this work is to present artificial hydrocarbon networks as a novel flexible approach in a human activity recognition system. In order to evaluate the performance of artificial hydrocarbon networks based classifier, experimentation was designed for user-independent, and also for user-dependent case scenarios. Our results demonstrate that artificial hydrocarbon networks classifier is flexible enough to be used when building a human activity recognition system with either user-dependent or user-independent approaches. PMID:27792136

  7. A Flexible Approach for Human Activity Recognition Using Artificial Hydrocarbon Networks.

    PubMed

    Ponce, Hiram; Miralles-Pechuán, Luis; Martínez-Villaseñor, María de Lourdes

    2016-10-25

    Physical activity recognition based on sensors is a growing area of interest given the great advances in wearable sensors. Applications in various domains are taking advantage of the ease of obtaining data to monitor personal activities and behavior in order to deliver proactive and personalized services. Although many activity recognition systems have been developed for more than two decades, there are still open issues to be tackled with new techniques. We address in this paper one of the main challenges of human activity recognition: Flexibility. Our goal in this work is to present artificial hydrocarbon networks as a novel flexible approach in a human activity recognition system. In order to evaluate the performance of artificial hydrocarbon networks based classifier, experimentation was designed for user-independent, and also for user-dependent case scenarios. Our results demonstrate that artificial hydrocarbon networks classifier is flexible enough to be used when building a human activity recognition system with either user-dependent or user-independent approaches.

  8. COSMIC monthly progress report

    NASA Technical Reports Server (NTRS)

    1994-01-01

    Activities of the Computer Software Management and Information Center (COSMIC) are summarized for the month of May 1994. Tables showing the current inventory of programs available from COSMIC are presented and program processing and evaluation activities are summarized. Nine articles were prepared for publication in the NASA Tech Brief Journal. These articles (included in this report) describe the following software items: (1) WFI - Windowing System for Test and Simulation; (2) HZETRN - A Free Space Radiation Transport and Shielding Program; (3) COMGEN-BEM - Composite Model Generation-Boundary Element Method; (4) IDDS - Interactive Data Display System; (5) CET93/PC - Chemical Equilibrium with Transport Properties, 1993; (6) SDVIC - Sub-pixel Digital Video Image Correlation; (7) TRASYS - Thermal Radiation Analyzer System (HP9000 Series 700/800 Version without NASADIG); (8) NASADIG - NASA Device Independent Graphics Library, Version 6.0 (VAX VMS Version); and (9) NASADIG - NASA Device Independent Graphics Library, Version 6.0 (UNIX Version). Activities in the areas of marketing, customer service, benefits identification, maintenance and support, and dissemination are also described along with a budget summary.

  9. Indoor Navigation by People with Visual Impairment Using a Digital Sign System

    PubMed Central

    Legge, Gordon E.; Beckmann, Paul J.; Tjan, Bosco S.; Havey, Gary; Kramer, Kevin; Rolkosky, David; Gage, Rachel; Chen, Muzi; Puchakayala, Sravan; Rangarajan, Aravindhan

    2013-01-01

    There is a need for adaptive technology to enhance indoor wayfinding by visually-impaired people. To address this need, we have developed and tested a Digital Sign System. The hardware and software consist of digitally-encoded signs widely distributed throughout a building, a handheld sign-reader based on an infrared camera, image-processing software, and a talking digital map running on a mobile device. Four groups of subjects—blind, low vision, blindfolded sighted, and normally sighted controls—were evaluated on three navigation tasks. The results demonstrate that the technology can be used reliably in retrieving information from the signs during active mobility, in finding nearby points of interest, and following routes in a building from a starting location to a destination. The visually impaired subjects accurately and independently completed the navigation tasks, but took substantially longer than normally sighted controls. This fully functional prototype system demonstrates the feasibility of technology enabling independent indoor navigation by people with visual impairment. PMID:24116156

  10. Prioritizing guideline topics: development and evaluation of a practical tool.

    PubMed

    Ketola, Eeva; Toropainen, Erja; Kaila, Minna; Luoto, Riitta; Mäkelä, Marjukka

    2007-08-01

    A clear process for selecting and adopting clinical practice guidelines in the new topic areas is needed. The aim of this study is to design and develop a practical tool to assess guideline topics that have been suggested to the organization responsible for producing guidelines. We carried out an iterative development, feasibility and validation study of a guideline topic prioritization tool. The setting included the guideline producer organization and the tax-funded health care system. In the first stage of the tool development, participants were researchers, members of the Current Care Board and experts from health care organizations. In the second stage, the evaluation was done internally within the project by three independent reviewers. The main outcome measures were responses to an evaluation questionnaire, qualitative process feedback and analysis of the performance of the instrument on a random set of guidelines. Evaluations by three independent reviewers revealed good agreement and face validity with respect to its feasibility as a planning tool at the guideline board level. Feedback from board members suggested that the instrument is useful in prioritizing guideline topics. This instrument was accepted for use by the Board. Further developments are needed to ensure feedback and acceptability of the instrument by those proposing topics.

  11. [Validation of two indices of biological integrity (IBI) for the Angulo River subbasin in Central Mexico].

    PubMed

    Ramírez-Herrejón, Juan Pablo; Mercado-Silva, Norman; Medina-Nava, Martina; Domínguez-Domínguez, Omar

    2012-12-01

    Efforts to halt freshwater ecosystem degradation in central Mexico can benefit from using bio-monitoring tools that reflect the condition of their biotic integrity. We analyzed the applicability of two fish-based indices of biotic integrity using data from lotic and lentic systems in the Angulo River subbasin (Lerma-Chapala basin). Both independent data from our own collections during two consecutive years, and existing information detailing the ecological attributes of each species, were used to calculate indices of biological integrity for 16 sites in lotic and lentic habitats. We assessed environmental quality by combining independent evaluations water and habitat quality for each site. We found sites with poor, regular and good biotic integrity. Our study did not find sites with good environmental quality. Fish-based IBI scores were strongly and significantly correlated with scores from independent environmental assessment techniques. IBI scores were adequate at representing environmental conditions in most study sites. These results expand the area where a lotic system fish-based IBI can be used, and constitute an initial validation of a lentic system fish-based IBI. Our results suggest that these bio-monitoring tools can be used in future conservation efforts in freshwater ecosystems in the Middle Lerma Basin.

  12. World energy projection system: Model documentation

    NASA Astrophysics Data System (ADS)

    1992-06-01

    The World Energy Project System (WEPS) is an accounting framework that incorporates projects from independently documented models and assumptions about the future energy intensity of economic activity (ratios of total energy consumption divided by gross domestic product) and about the rate of incremental energy requirements met by hydropower, geothermal, coal, and natural gas to produce projections of world energy consumption published annually by the Energy Information Administration (EIA) in the International Energy Outlook (IEO). Two independently documented models presented in Figure 1, the Oil Market Simulation (OMS) model and the World Integrated Nuclear Evaluation System (WINES), provide projections of oil and nuclear power consumption published in the IEO. Output from a third independently documented model, and the International Coal Trade Model (ICTM), is not published in the IEO but is used in WEPS as a supply check on projections of world coal consumption produced by WEPS and published in the IEO. A WEPS model of natural gas production documented in this report provides the same type of implicit supply check on the WEPS projections of world natural gas consumption published in the IEO. Two additional models are included in Figure 1, the OPEC Capacity model and the Non-OPEC Oil Production model. These WEPS models provide inputs to the OMS model and are documented in this report.

  13. Voice response system of color and pattern on clothes for visually handicapped person.

    PubMed

    Miyake, Masao; Manabe, Yoshitsugu; Uranishi, Yuki; Imura, Masataka; Oshiro, Osamu

    2013-01-01

    For visually handicapped people, a mental support is important in their independent daily life and participation in a society. It is expected to develop a system which can recognize colors and patterns on clothes so that they can go out with less concerns. We have worked on a basic study into such a system, and developed a prototype system which can stably recognize colors and patterns and immediately provide these information in voice, when a user faces it to clothes. In the results of evaluation experiments it is shown that the prototype system is superior to the system in the basic study at the accuracy rate for the recognition of color and pattern.

  14. 78 FR 29364 - Independent Power Producers of New York, Inc. v. New York Independent System Operator, Inc.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-20

    ... Power Producers of New York, Inc. v. New York Independent System Operator, Inc. Notice of Complaint Take notice that on May 10, 2013, Independent Power Producers of New York, Inc. (IPPNY or Complainant) filed a complaint against New York Independent System Operator, Inc. (NYISO or Respondent), pursuant to [[Page 29365...

  15. Molecular vibrational states during a collision

    NASA Technical Reports Server (NTRS)

    Recamier, Jose A.; Jauregui, Rocio

    1995-01-01

    Alternative algebraic techniques to approximate a given Hamiltonian by a harmonic oscillator are described both for time-independent and time-dependent systems. We apply them to the description of a one dimensional atom-diatom collision. From the resulting evolution operator, we evaluate vibrational transition probabilities as well as other time-dependent properties. As expected, the ground vibrational state becomes a squeezed state during the collision.

  16. Using a Personal Digital Assistant to Increase Independent Task Completion by Students with Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Mechling, Linda C.; Gast, David L.; Seid, Nicole H.

    2009-01-01

    In this study, a personal digital assistant (PDA) with picture, auditory, and video prompts with voice over, was evaluated as a portable self-prompting device for students with autism spectrum disorder (ASD). Using a multiple probe design across three cooking recipes and replicated with three students with ASD, the system was tested for its…

  17. Guidelines for point-of-care testing: haematology.

    PubMed

    Briggs, Carol; Guthrie, David; Hyde, Keith; Mackie, Ian; Parker, Norman; Popek, Mary; Porter, Neil; Stephens, Clare

    2008-09-01

    This guideline provides a framework for the arrangement of point-of-care testing (POCT) services, previously known as near patient testing (patient self-testing not covered). POCT is defined as any analytical test performed outside the laboratory. Primary users are often non-laboratory healthcare workers. The guidance applies to units within hospitals as well as general practioner surgeries, community clinics and pharmacies. The head of the haematology laboratory or a point of care coordinator must take responsibility for all aspects of the POCT service, including quality and training. Depending on the size and nature of the POCT practice, a local POCT manager may also be required. Equipment selected should have received a successful independent performance evaluation. If an independent evaluation has not been performed the purchaser should assess the device according to the protocol in this document. POCT devices should generate results that are comparable to those of the local laboratory. An accredited external quality assessment programme and internal quality control system must be established. Manufacturers promoting POCT devices designed for non-laboratory sites, e.g. pharmacies, should undertake training and annual competency assessment, perhaps using a web-based system. A diagram to illustrate the stages for the implementation of a POCT service is illustrated.

  18. Sensitivity of the Dengue Surveillance System in Brazil for Detecting Hospitalized Cases

    PubMed Central

    2016-01-01

    We evaluated the sensitivity of the dengue surveillance system in detecting hospitalized cases in ten capital cities in Brazil from 2008 to 2013 using a probabilistic record linkage of two independent information systems hospitalization (SIH-SUS) adopted as the gold standard and surveillance (SINAN). Sensitivity was defined as the proportion of cases reported to the surveillance system amid the suspected hospitalized cases registered in SIH-SUS. Of the 48,174 hospitalizations registered in SIH-SUS, 24,469 (50.7%) were reported and registered in SINAN, indicating an overall sensitivity of 50.8% (95%CI 50.3–51.2). The observed sensitivity for each of the municipalities included in the study ranged from 22.0% to 99.1%. The combination of the two data sources identified 71,161 hospitalizations, an increase of 97.0% over SINAN itself. Our results allowed establishing the proportion of underreported dengue hospitalizations in the public health system in Brazil, highlighting the use of probabilistic record linkage as a valuable tool for evaluating surveillance systems. PMID:27192405

  19. PFB Coal Fired Combined Cycle Development Program. Advanced hot gas cleanup concept evaluation (Task 4. 3). Volume A. Aerodyne cyclone evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This report summarizes the results of testing of a rotary flow cyclone, manufactured by Aerodyne Development Corporation under license by Siemens Kraftwerk Union. This cyclone was selected for evaluation due to the unusually high separative efficiencies claimed by the manufacturer (based on developer data), and relative lack of open literature data. The most significant finding of this work was the observation that electrostatic forces could enhance or, in fact, dominate the separation process. Separative efficiencies, with electrostatic forces present, were found to be substantially independent of flow rate and, by inference, could be independent of unit size. Hence this findingmore » offers a major hope that large cyclones employed in the hot gas cleanup train of the CFCC system may not suffer the performance degradation compared to small cyclones, as projected from conventional inertial theory. The separative efficiencies of the Aerodyne cyclone separator were found from both the cold flow and the hot flow tests to be disappointingly poorer than expectations (in agreement with Westinghouse results), and even poorer than conventional cyclones. (LTN)« less

  20. Development and clinical validation of a novel photography-based skin erythema evaluation system: a comparison with the calculated consensus of dermatologists.

    PubMed

    Cho, M; Lee, D-H; Doh, E J; Kim, Y; Chung, J H; Kim, H C; Kim, S

    2017-08-01

    Erythema is the most common presenting sign in patients with skin diseases, and various methods to treat erythema symptoms have become common. To evaluate changes in erythema, a reliable device that can support objective diagnosis is required. We developed a novel photography-based system for erythema diagnosis that provides a high-resolution three-view photograph taken in a consistent photography environment with a curved surface light source and can be integrated with optimized image processing algorithms. A new diagnostic algorithm was applied to photographs from 32 patients to determine areas of erythema automatically. To assess the performance in comparison to dermatologists' evaluations, five dermatologists independently evaluate the areas of erythema, and we defined an area called the clinical consensus area of erythema (CCAE), which is based on the majority opinion of dermatologists during evaluation. The CCAE values obtained were compared with the erythema areas determined by the system's diagnostic algorithm. Forty-one photographs with areas of erythema were evaluated by the proposed system and by dermatologists. The results obtained with the proposed system had a mean accuracy of 93.18% with a standard deviation of 3.52% when compared with the CCAE results. The results also showed that the proposed system could detect erythema areas without any pigmentation. In contrast to assessments by individual dermatologists, use of the CCAE reduced the amount of error that occurred owing to bias or subjectivity. A new erythema evaluation system was developed and validated through CCAE, suggesting that the system can support dermatologists' objective diagnoses of erythema. © 2017 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  1. SU-E-T-762: Toward Volume-Based Independent Dose Verification as Secondary Check

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tachibana, H; Tachibana, R

    2015-06-15

    Purpose: Lung SBRT plan has been shifted to volume prescription technique. However, point dose agreement is still verified using independent dose verification at the secondary check. The volume dose verification is more affected by inhomogeneous correction rather than point dose verification currently used as the check. A feasibility study for volume dose verification was conducted in lung SBRT plan. Methods: Six SBRT plans were collected in our institute. Two dose distributions with / without inhomogeneous correction were generated using Adaptive Convolve (AC) in Pinnacle3. Simple MU Analysis (SMU, Triangle Product, Ishikawa, JP) was used as the independent dose verification softwaremore » program, in which a modified Clarkson-based algorithm was implemented and radiological path length was computed using CT images independently to the treatment planning system. The agreement in point dose and mean dose between the AC with / without the correction and the SMU were assessed. Results: In the point dose evaluation for the center of the GTV, the difference shows the systematic shift (4.5% ± 1.9 %) in comparison of the AC with the inhomogeneous correction, on the other hands, there was good agreement of 0.2 ± 0.9% between the SMU and the AC without the correction. In the volume evaluation, there were significant differences in mean dose for not only PTV (14.2 ± 5.1 %) but also GTV (8.0 ± 5.1 %) compared to the AC with the correction. Without the correction, the SMU showed good agreement for GTV (1.5 ± 0.9%) as well as PTV (0.9% ± 1.0%). Conclusion: The volume evaluation for secondary check may be possible in homogenous region. However, the volume including the inhomogeneous media would make larger discrepancy. Dose calculation algorithm for independent verification needs to be modified to take into account the inhomogeneous correction.« less

  2. 46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Liquid level alarm system: Independent tank type C. 154..., Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type C. Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if: (a) The tank...

  3. 46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Liquid level alarm system: Independent tank type C. 154..., Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type C. Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if: (a) The tank...

  4. 46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Liquid level alarm system: Independent tank type C. 154..., Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type C. Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if: (a) The tank...

  5. 46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Liquid level alarm system: Independent tank type C. 154..., Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type C. Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if: (a) The tank...

  6. 46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Liquid level alarm system: Independent tank type C. 154..., Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type C. Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if: (a) The tank...

  7. 77 FR 52137 - Proposed Order and Request for Comment on a Petition From Certain Independent System Operators...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-28

    ... New York Independent System Operator, Inc.; and In the Matter of the Petition for an Exemptive Order... Independent System Operator (``CAISO'') and New York Independent System Operator (``NYISO'')), whose central... Commodity Exchange Act by ISO New England Inc.; In the Matter of the Petition for an Exemptive Order Under...

  8. Advanced Technology Lifecycle Analysis System (ATLAS) Technology Tool Box (TTB)

    NASA Technical Reports Server (NTRS)

    Doyle, Monica; ONeil, Daniel A.; Christensen, Carissa B.

    2005-01-01

    The Advanced Technology Lifecycle Analysis System (ATLAS) is a decision support tool designed to aid program managers and strategic planners in determining how to invest technology research and development dollars. It is an Excel-based modeling package that allows a user to build complex space architectures and evaluate the impact of various technology choices. ATLAS contains system models, cost and operations models, a campaign timeline and a centralized technology database. Technology data for all system models is drawn from a common database, the ATLAS Technology Tool Box (TTB). The TTB provides a comprehensive, architecture-independent technology database that is keyed to current and future timeframes.

  9. The intraductal approach to the breast: raison d'être

    PubMed Central

    King, Bonnie L; Love, Susan M

    2006-01-01

    Opportunities for the detection, prediction, and treatment of breast cancer exist at three biological levels: systemically via the blood, at the whole organ level, and within the individual ductal lobular structures of the breast. This review covers the evaluation of approaches targeted to the ductal lobular units, where breast cancer begins. Studies to date suggest the presence of 5 to 12 independent ductal lobular systems per breast, each harboring complex cellular fluids contributed by local and systemic processes. New techniques for accessing and interrogating these systems offer the potential to gauge the microenvironment of the breast and distill biological risk profiles. PMID:16677416

  10. A Hybrid Evaluation System Framework (Shell & Web) with Standardized Access to Climate Model Data and Verification Tools for a Clear Climate Science Infrastructure on Big Data High Performance Computers

    NASA Astrophysics Data System (ADS)

    Kadow, C.; Illing, S.; Kunst, O.; Cubasch, U.

    2014-12-01

    The project 'Integrated Data and Evaluation System for Decadal Scale Prediction' (INTEGRATION) as part of the German decadal prediction project MiKlip develops a central evaluation system. The fully operational hybrid features a HPC shell access and an user friendly web-interface. It employs one common system with a variety of verification tools and validation data from different projects in- and outside of MiKlip. The evaluation system is located at the German Climate Computing Centre (DKRZ) and has direct access to the bulk of its ESGF node including millions of climate model data sets, e.g. from CMIP5 and CORDEX. The database is organized by the international CMOR standard using the meta information of the self-describing model, reanalysis and observational data sets. Apache Solr is used for indexing the different data projects into one common search environment. This implemented meta data system with its advanced but easy to handle search tool supports users, developers and their tools to retrieve the required information. A generic application programming interface (API) allows scientific developers to connect their analysis tools with the evaluation system independently of the programming language used. Users of the evaluation techniques benefit from the common interface of the evaluation system without any need to understand the different scripting languages. Facilitating the provision and usage of tools and climate data increases automatically the number of scientists working with the data sets and identify discrepancies. Additionally, the history and configuration sub-system stores every analysis performed with the evaluation system in a MySQL database. Configurations and results of the tools can be shared among scientists via shell or web-system. Therefore, plugged-in tools gain automatically from transparency and reproducibility. Furthermore, when configurations match while starting a evaluation tool, the system suggests to use results already produced by other users-saving CPU time, I/O and disk space. This study presents the different techniques and advantages of such a hybrid evaluation system making use of a Big Data HPC in climate science. website: www-miklip.dkrz.de visitor-login: guest password: miklip

  11. A Hybrid Evaluation System Framework (Shell & Web) with Standardized Access to Climate Model Data and Verification Tools for a Clear Climate Science Infrastructure on Big Data High Performance Computers

    NASA Astrophysics Data System (ADS)

    Kadow, Christopher; Illing, Sebastian; Kunst, Oliver; Ulbrich, Uwe; Cubasch, Ulrich

    2015-04-01

    The project 'Integrated Data and Evaluation System for Decadal Scale Prediction' (INTEGRATION) as part of the German decadal prediction project MiKlip develops a central evaluation system. The fully operational hybrid features a HPC shell access and an user friendly web-interface. It employs one common system with a variety of verification tools and validation data from different projects in- and outside of MiKlip. The evaluation system is located at the German Climate Computing Centre (DKRZ) and has direct access to the bulk of its ESGF node including millions of climate model data sets, e.g. from CMIP5 and CORDEX. The database is organized by the international CMOR standard using the meta information of the self-describing model, reanalysis and observational data sets. Apache Solr is used for indexing the different data projects into one common search environment. This implemented meta data system with its advanced but easy to handle search tool supports users, developers and their tools to retrieve the required information. A generic application programming interface (API) allows scientific developers to connect their analysis tools with the evaluation system independently of the programming language used. Users of the evaluation techniques benefit from the common interface of the evaluation system without any need to understand the different scripting languages. Facilitating the provision and usage of tools and climate data increases automatically the number of scientists working with the data sets and identify discrepancies. Additionally, the history and configuration sub-system stores every analysis performed with the evaluation system in a MySQL database. Configurations and results of the tools can be shared among scientists via shell or web-system. Therefore, plugged-in tools gain automatically from transparency and reproducibility. Furthermore, when configurations match while starting a evaluation tool, the system suggests to use results already produced by other users-saving CPU time, I/O and disk space. This study presents the different techniques and advantages of such a hybrid evaluation system making use of a Big Data HPC in climate science. website: www-miklip.dkrz.de visitor-login: click on "Guest"

  12. Continuous performance measurement in flight systems. [sequential control model

    NASA Technical Reports Server (NTRS)

    Connelly, E. M.; Sloan, N. A.; Zeskind, R. M.

    1975-01-01

    The desired response of many man machine control systems can be formulated as a solution to an optimal control synthesis problem where the cost index is given and the resulting optimal trajectories correspond to the desired trajectories of the man machine system. Optimal control synthesis provides the reference criteria and the significance of error information required for performance measurement. The synthesis procedure described provides a continuous performance measure (CPM) which is independent of the mechanism generating the control action. Therefore, the technique provides a meaningful method for online evaluation of man's control capability in terms of total man machine performance.

  13. Independent Evaluation of Middle School-Based Drug Prevention Curricula: A Systematic Review.

    PubMed

    Flynn, Anna B; Falco, Mathea; Hocini, Sophia

    2015-11-01

    Lack of robust program evaluation has hindered the effectiveness of school-based drug abuse prevention curricula overall. Independently evaluated randomized controlled trials (RCTs) of universal, middle school-based drug abuse prevention curricula are the most useful indicators of whether such programs are effective or ineffective. To conduct a systematic review identifying independently evaluated RCTs of universal, middle school-based drug abuse prevention curricula; extract data on study quality and substance use outcomes; and assess evidence of program effectiveness. PsycInfo, Educational Resources Information Center, Science Citation Index, Social Science Citation Index, Cumulative Index to Nursing and Allied Health Literature, MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews were searched between January 1, 1984, and March 15, 2015. Search terms included variations of drug, alcohol, tobacco, and marijuana use, as well as school, prevention, and effectiveness. Studies included in the review were RCTs carried out by independent evaluators of universal school-based drug prevention curricula available for dissemination in the United States that reported alcohol, tobacco, marijuana, or other drug use outcomes. Two researchers extracted data on study quality and outcomes independently using a data extraction form and met to resolve disagreements. A total of 5071 publications were reviewed, with 13 articles meeting final inclusion criteria. Of the 13 articles, 6 RCTs of 4 distinct school-based curricula were identified for inclusion. Outcomes were reported for 42 single-drug measures in the independent RCTs, with just 3 presenting statistically significant (P < .05) differences between the intervention group and the control group. One program revealed statistically significant positive effects at final follow-up (Lions-Quest Skills for Adolescence). The results of our review demonstrate the dearth of independent research that appropriately evaluates the effectiveness of universal, middle school-based drug prevention curricula. Independent evaluations show little evidence of effectiveness for widely used programs. New methods may be necessary to approach school-based adolescent drug prevention.

  14. Evaluation of the Technicon Axon analyser.

    PubMed

    Martínez, C; Márquez, M; Cortés, M; Mercé, J; Rodriguez, J; González, F

    1990-01-01

    An evaluation of the Technicon Axon analyser was carried out following the guidelines of the 'Sociedad Española de Química Clínica' and the European Committee for Clinical Laboratory Standards.A photometric study revealed acceptable results at both 340 nm and 404 nm. Inaccuracy and imprecision were lower at 404 nm than at 340 nm, although poor dispersion was found at both wavelengths, even at low absorbances. Drift was negligible, the imprecision of the sample pipette delivery system was greater for small sample volumes, the reagent pipette delivery system imprecision was acceptable and the sample diluting system study showed good precision and accuracy.Twelve analytes were studied for evaluation of the analyser under routine working conditions. Satisfactory results were obtained for within-run imprecision, while coefficients of variation for betweenrun imprecision were much greater than expected. Neither specimenrelated nor specimen-independent contamination was found in the carry-over study. For all analytes assayed, when comparing patient sample results with those obtained in a Hitachi 737 analyser, acceptable relative inaccuracy was observed.

  15. Higher-order scene statistics of breast images

    NASA Astrophysics Data System (ADS)

    Abbey, Craig K.; Sohl-Dickstein, Jascha N.; Olshausen, Bruno A.; Eckstein, Miguel P.; Boone, John M.

    2009-02-01

    Researchers studying human and computer vision have found description and construction of these systems greatly aided by analysis of the statistical properties of naturally occurring scenes. More specifically, it has been found that receptive fields with directional selectivity and bandwidth properties similar to mammalian visual systems are more closely matched to the statistics of natural scenes. It is argued that this allows for sparse representation of the independent components of natural images [Olshausen and Field, Nature, 1996]. These theories have important implications for medical image perception. For example, will a system that is designed to represent the independent components of natural scenes, where objects occlude one another and illumination is typically reflected, be appropriate for X-ray imaging, where features superimpose on one another and illumination is transmissive? In this research we begin to examine these issues by evaluating higher-order statistical properties of breast images from X-ray projection mammography (PM) and dedicated breast computed tomography (bCT). We evaluate kurtosis in responses of octave bandwidth Gabor filters applied to PM and to coronal slices of bCT scans. We find that kurtosis in PM rises and quickly saturates for filter center frequencies with an average value above 0.95. By contrast, kurtosis in bCT peaks near 0.20 cyc/mm with kurtosis of approximately 2. Our findings suggest that the human visual system may be tuned to represent breast tissue more effectively in bCT over a specific range of spatial frequencies.

  16. Evaluation of functional independence after discharge from the intensive care unit

    PubMed Central

    Curzel, Juliane; Forgiarini Junior, Luiz Alberto; Rieder, Marcelo de Mello

    2013-01-01

    Objective 1) To evaluate the functional independence measures immediately after discharge from an intensive care unit and to compare these values with the FIMs 30 days after that period. 2) To evaluate the possible associated risk factors. Methods The present investigation was a prospective cohort study that included individuals who were discharged from the intensive care unit and underwent physiotherapy in the unit. Functional independence was evaluated using the functional independence measure immediately upon discharge from the intensive care unit and 30 days thereafter via a phone call. The patients were admitted to the Hospital Santa Clara intensive care unit during the period from May 2011 to August 2011. Results During the predetermined period of data collection, 44 patients met the criteria for inclusion in the study. The mean age of the patients was 55.4±10.5 years. Twenty-seven of the subjects were female, and 15 patients were admitted due to pulmonary disease. The patients exhibited an functional independence measure of 84.1±24.2. When this measure was compared to the measure at 30 days after discharge, there was improvement across the functional independence variables except for that concerned with sphincter control. There were no significant differences when comparing the gender, age, clinical diagnosis, length of stay in the intensive care unit, duration of mechanical ventilation, and the presence of sepsis during this period. Conclusion Functional independence, as evaluated by the functional independence measure scale, was improved at 30 days after discharge from the intensive care unit, but it was not possible to define the potentially related factors. PMID:23917973

  17. 7 CFR 1212.61 - Independent evaluation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Independent evaluation. 1212.61 Section 1212.61 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... evaluation of the effectiveness of this subpart and the plans and programs conducted by the Board under the...

  18. The National Aeronautics and Space Administration Nondestructive Evaluation Program for Safe and Reliable Operations

    NASA Technical Reports Server (NTRS)

    Generazio, Ed

    2005-01-01

    The National Aeronautics and Space Administration (NASA) Nondestructive Evaluation (NDE) Program is presented. As a result of the loss of seven astronauts and the Space Shuttle Columbia on February 1, 2003, NASA has undergone many changes in its organization. NDE is one of the key areas that are recognized by the Columbia Accident Investigation Board (CAIB) that needed to be strengthened by warranting NDE as a discipline with Independent Technical Authority (iTA). The current NASA NDE system and activities are presented including the latest developments in inspection technologies being applied to the Space Transportation System (STS). The unfolding trends and directions in NDE for the future are discussed as they apply to assuring safe and reliable operations.

  19. 14 CFR 125.179 - Fuel system independence.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Fuel system independence. 125.179 Section... Requirements § 125.179 Fuel system independence. (a) Each airplane fuel system must be arranged so that the... the fuel system incorporates features that provide equivalent safety. ...

  20. 14 CFR 125.179 - Fuel system independence.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fuel system independence. 125.179 Section... Requirements § 125.179 Fuel system independence. (a) Each airplane fuel system must be arranged so that the... the fuel system incorporates features that provide equivalent safety. ...

  1. 14 CFR 125.179 - Fuel system independence.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Fuel system independence. 125.179 Section... Requirements § 125.179 Fuel system independence. (a) Each airplane fuel system must be arranged so that the... the fuel system incorporates features that provide equivalent safety. ...

  2. Classifying Adverse Events in the Dental Office.

    PubMed

    Kalenderian, Elsbeth; Obadan-Udoh, Enihomo; Maramaldi, Peter; Etolue, Jini; Yansane, Alfa; Stewart, Denice; White, Joel; Vaderhobli, Ram; Kent, Karla; Hebballi, Nutan B; Delattre, Veronique; Kahn, Maria; Tokede, Oluwabunmi; Ramoni, Rachel B; Walji, Muhammad F

    2017-06-30

    Dentists strive to provide safe and effective oral healthcare. However, some patients may encounter an adverse event (AE) defined as "unnecessary harm due to dental treatment." In this research, we propose and evaluate two systems for categorizing the type and severity of AEs encountered at the dental office. Several existing medical AE type and severity classification systems were reviewed and adapted for dentistry. Using data collected in previous work, two initial dental AE type and severity classification systems were developed. Eight independent reviewers performed focused chart reviews, and AEs identified were used to evaluate and modify these newly developed classifications. A total of 958 charts were independently reviewed. Among the reviewed charts, 118 prospective AEs were found and 101 (85.6%) were verified as AEs through a consensus process. At the end of the study, a final AE type classification comprising 12 categories, and an AE severity classification comprising 7 categories emerged. Pain and infection were the most common AE types representing 73% of the cases reviewed (56% and 17%, respectively) and 88% were found to cause temporary, moderate to severe harm to the patient. Adverse events found during the chart review process were successfully classified using the novel dental AE type and severity classifications. Understanding the type of AEs and their severity are important steps if we are to learn from and prevent patient harm in the dental office.

  3. Hybrid Approach for Automatic Evaluation of Emotion Elicitation Oriented to People with Intellectual Disabilities

    NASA Astrophysics Data System (ADS)

    Martínez, R.; de Ipiña, K. López; Irigoyen, E.; Asla, N.

    People with intellectual disabilities and elderly need physical and intellectual support to ensuring independent living. This is one of the main issues in applying Information and Communication Technology (ICT) into Assistive Technology field. In this sense the development of appropriated Intelligent Systems (ISs) offers new perspectives to this community. In our project a new IS system (LAGUNTXO) which adds user affective information oriented to people with intellectual disabilities has been developed. The system integrates a Human Emotion Analysis System (HEAS) which attempts to solve critical situations for this community as block stages. In the development of the HEAS one of the critical issues was to create appropriated databases to train the system due to the difficulty to simulate pre-block stages in laboratory. Finally a films and real sequences based emotion elicitation database was created. The elicitation material was categorized with more actual features based on discrete emotions and dimensional terms (pleasant, unpleasant). Classically the evaluation is carried out by a specialist (psychologist). In this work we present a hybrid approach for Automatic Evaluation of Emotion Elicitation databases based on Machine Learning classifiers and K-means clustering. The new categorization and the automatic evaluation show a high level of accuracy with respect to others methodologies presented in the literature.

  4. Contracting for independent evaluation: approaches to an inherent tension.

    PubMed

    Klerman, Jacob Alex

    2010-08-01

    There has recently been discussion of whether independent contract evaluation is possible. This article acknowledges the inherent tension in contract evaluation and in response suggests a range of constructive approaches to improving the independence of contract evaluation. In particular, a clear separation between the official evaluation report and a contractor's own publication of analysis from the underlying evaluation appears to be a promising approach. In this approach, the funder would retain almost unfettered rights to the official contract report (including the right never to publish but not the right to change the contractor's text while leaving the contractor's authorship) and the contractor would retain clearly defined rights to publish any findings from the evaluation (subject only to the limitations of human subjects and proprietary data and some minimal notice).

  5. Austin Independent School District Office of Program Evaluation Agenda 1998-99. Publication Number 98.01.

    ERIC Educational Resources Information Center

    Austin Independent School District, TX. Office of Program Evaluation.

    The Office of Program Evaluation (OPE) of the Austin Independent School District (Texas) (AISD) is charged with evaluating federally, locally, and state funded programs in the AISD. OPE staff carry out mandated reporting for federal and state grants and are increasingly involved in formative evaluations designed for program improvement and…

  6. Independent Consulting and the American Evaluation Association: Twenty Years Later

    ERIC Educational Resources Information Center

    Bonnet, Deborah G.

    2006-01-01

    This article reviews the evolution of American Evaluation Association's (AEA) Independent Consulting Topical Interest Group (IC TIG). The TIG goes back a joint meeting held in San Francisco in 1984 of the Evaluation Network (ENet) and the Evaluation Research Society (ERS), two years before the organizations merged to become the AEA. On the fringes…

  7. Re-evaluating the functional landscape of the cardiovascular system during development

    PubMed Central

    Takada, Norio; Omae, Madoka; Sagawa, Fumihiko; Chi, Neil C.; Endo, Satsuki; Kozawa, Satoshi

    2017-01-01

    ABSTRACT The cardiovascular system facilitates body-wide distribution of oxygen, a vital process for the development and survival of virtually all vertebrates. However, the zebrafish, a vertebrate model organism, appears to form organs and survive mid-larval periods without a functional cardiovascular system. Despite such dispensability, it is the first organ to develop. Such enigma prompted us to hypothesize other cardiovascular functions that are important for developmental and/or physiological processes. Hence, systematic cellular ablations and functional perturbations were performed on the zebrafish cardiovascular system to gain comprehensive and body-wide understanding of such functions and to elucidate the underlying mechanisms. This approach identifies a set of organ-specific genes, each implicated for important functions. The study also unveils distinct cardiovascular mechanisms, each differentially regulating their expressions in organ-specific and oxygen-independent manners. Such mechanisms are mediated by organ-vessel interactions, circulation-dependent signals, and circulation-independent beating-heart-derived signals. A comprehensive and body-wide functional landscape of the cardiovascular system reported herein may provide clues as to why it is the first organ to develop. Furthermore, these data could serve as a resource for the study of organ development and function. PMID:28982700

  8. Re-evaluating the functional landscape of the cardiovascular system during development.

    PubMed

    Takada, Norio; Omae, Madoka; Sagawa, Fumihiko; Chi, Neil C; Endo, Satsuki; Kozawa, Satoshi; Sato, Thomas N

    2017-11-15

    The cardiovascular system facilitates body-wide distribution of oxygen, a vital process for the development and survival of virtually all vertebrates. However, the zebrafish, a vertebrate model organism, appears to form organs and survive mid-larval periods without a functional cardiovascular system. Despite such dispensability, it is the first organ to develop. Such enigma prompted us to hypothesize other cardiovascular functions that are important for developmental and/or physiological processes. Hence, systematic cellular ablations and functional perturbations were performed on the zebrafish cardiovascular system to gain comprehensive and body-wide understanding of such functions and to elucidate the underlying mechanisms. This approach identifies a set of organ-specific genes, each implicated for important functions. The study also unveils distinct cardiovascular mechanisms, each differentially regulating their expressions in organ-specific and oxygen-independent manners. Such mechanisms are mediated by organ-vessel interactions, circulation-dependent signals, and circulation-independent beating-heart-derived signals. A comprehensive and body-wide functional landscape of the cardiovascular system reported herein may provide clues as to why it is the first organ to develop. Furthermore, these data could serve as a resource for the study of organ development and function. © 2017. Published by The Company of Biologists Ltd.

  9. Comparison of two heuristic evaluation methods for evaluating the usability of health information systems.

    PubMed

    Khajouei, Reza; Hajesmaeel Gohari, Sadrieh; Mirzaee, Moghaddameh

    2018-04-01

    In addition to following the usual Heuristic Evaluation (HE) method, the usability of health information systems can also be evaluated using a checklist. The objective of this study is to compare the performance of these two methods in identifying usability problems of health information systems. Eight evaluators independently evaluated different parts of a Medical Records Information System using two methods of HE (usual and with a checklist). The two methods were compared in terms of the number of problems identified, problem type, and the severity of identified problems. In all, 192 usability problems were identified by two methods in the Medical Records Information System. This was significantly higher than the number of usability problems identified by the checklist and usual method (148 and 92, respectively) (p < 0.0001). After removing the duplicates, the difference between the number of unique usability problems identified by the checklist method (n = 100) and usual method (n = 44) was significant (p < 0.0001). Differences between the mean severity of the real usability problems (1.83) and those identified by only one of the methods (usual = 2.05, checklist = 1.74) were significant (p = 0.001). This study revealed the potential of the two HE methods for identifying usability problems of health information systems. The results demonstrated that the checklist method had significantly better performance in terms of the number of identified usability problems; however, the performance of the usual method for identifying problems of higher severity was significantly better. Although the checklist method can be more efficient for less experienced evaluators, wherever usability is critical, the checklist should be used with caution in usability evaluations. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Northeast Inspection Services, Inc. boresonic inspection system evaluation. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nottingham, L.D.; Sabourin, P.F.; Presson, J.H.

    1993-04-01

    Turbine rotor reliability and remaining life assessment are continuing concerns to electric utilities. Over the years, boresonic inspection and evaluation have served as primary components in rotor remaining life assessment. Beginning with an evaluation of TREES by EPRI in 1982, a series of reports that document the detection and sizing capabilities of several boresonic systems have been made available. These studies should provide utilities with a better understanding of system performance and lead to improved reliability when predicting rotor remaining life. In 1990, the procedures followed for evaluating rotor boresonic performance capabilities were changed to transfer a greater portion ofmore » the data analysis function to the participating vendor. This change from previous policy was instituted so that the evaluation results would better reflect the ``final answer`` that a vendor would provide in a real rotor inspection and also to reduce the cost of an evaluation. Among the first vendors to participate in the new performance demonstration was Northeast Inspection Services, Inc. (NISI). The tests reported herein were conducted by NISI personnel under the guidelines of the new plan. Details of the new evaluation plan are also presented. Rotor bore blocks containing surface-connected fatigue cracks, embedded glass beads, and embedded radial-axial oriented disks were used in the evaluation. Data were collected during twenty-five independent passes through the blocks. The evaluation consisted of statistical characterization of the detection capabilities, flaw sizing and location accuracy, and repeatability of the inspection system. The results of the evaluation are included in this report.« less

  11. Defining and reconstructing clinical processes based on IHE and BPMN 2.0.

    PubMed

    Strasser, Melanie; Pfeifer, Franz; Helm, Emmanuel; Schuler, Andreas; Altmann, Josef

    2011-01-01

    This paper describes the current status and the results of our process management system for defining and reconstructing clinical care processes, which contributes to compare, analyze and evaluate clinical processes and further to identify high cost tasks or stays. The system is founded on IHE, which guarantees standardized interfaces and interoperability between clinical information systems. At the heart of the system there is BPMN, a modeling notation and specification language, which allows the definition and execution of clinical processes. The system provides functionality to define healthcare information system independent clinical core processes and to execute the processes in a workflow engine. Furthermore, the reconstruction of clinical processes is done by evaluating an IHE audit log database, which records patient movements within a health care facility. The main goal of the system is to assist hospital operators and clinical process managers to detect discrepancies between defined and actual clinical processes and as well to identify main causes of high medical costs. Beyond that, the system can potentially contribute to reconstruct and improve clinical processes and enhance cost control and patient care quality.

  12. Skylab program earth resources experiment package sensor performance evaluation, volume 1, (S190A)

    NASA Technical Reports Server (NTRS)

    Kenney, G. P.

    1975-01-01

    The results of S190A sensor performance evaluation are summarized based on data presented by all contributors to the sensor performance evaluation interim reports. Techniques used in sensor performance evaluation are discussed. Topics discussed include: performance degradation identified during the Skylab missions, S190A and EREP system anomalies that affected S190A performance, and the performance achieved, in terms of pertinent S190A parameters. Additional analyses include final performance analyses completed after submittal of the SL4 interim sensor performance evaluation reports, including completion of detailed analyses of basic performance parameters initiated during the interim report periods and consolidation analyses to reduce independent mission data (SL2, SL3, and SL4) to determine overall performance realized during all three Skylab missions.

  13. Incorporation of Personal Single Nucleotide Polymorphism (SNP) Data into a National Level Electronic Health Record for Disease Risk Assessment, Part 3: An Evaluation of SNP Incorporated National Health Information System of Turkey for Prostate Cancer

    PubMed Central

    Beyan, Timur

    2014-01-01

    Background A personalized medicine approach provides opportunities for predictive and preventive medicine. Using genomic, clinical, environmental, and behavioral data, the tracking and management of individual wellness is possible. A prolific way to carry this personalized approach into routine practices can be accomplished by integrating clinical interpretations of genomic variations into electronic medical records (EMRs)/electronic health records (EHRs). Today, various central EHR infrastructures have been constituted in many countries of the world, including Turkey. Objective As an initial attempt to develop a sophisticated infrastructure, we have concentrated on incorporating the personal single nucleotide polymorphism (SNP) data into the National Health Information System of Turkey (NHIS-T) for disease risk assessment, and evaluated the performance of various predictive models for prostate cancer cases. We present our work as a three part miniseries: (1) an overview of requirements, (2) the incorporation of SNP data into the NHIS-T, and (3) an evaluation of SNP data incorporated into the NHIS-T for prostate cancer. Methods In the third article of this miniseries, we have evaluated the proposed complementary capabilities (ie, knowledge base and end-user application) with real data. Before the evaluation phase, clinicogenomic associations about increased prostate cancer risk were extracted from knowledge sources, and published predictive genomic models assessing individual prostate cancer risk were collected. To evaluate complementary capabilities, we also gathered personal SNP data of four prostate cancer cases and fifteen controls. Using these data files, we compared various independent and model-based, prostate cancer risk assessment approaches. Results Through the extraction and selection processes of SNP-prostate cancer risk associations, we collected 209 independent associations for increased risk of prostate cancer from the studied knowledge sources. Also, we gathered six cumulative models and two probabilistic models. Cumulative models and assessment of independent associations did not have impressive results. There was one of the probabilistic, model-based interpretation that was successful compared to the others. In envirobehavioral and clinical evaluations, we found that some of the comorbidities, especially, would be useful to evaluate disease risk. Even though we had a very limited dataset, a comparison of performances of different disease models and their implementation with real data as use case scenarios helped us to gain deeper insight into the proposed architecture. Conclusions In order to benefit from genomic variation data, existing EHR/EMR systems must be constructed with the capability of tracking and monitoring all aspects of personal health status (genomic, clinical, environmental, etc) in 24/7 situations, and also with the capability of suggesting evidence-based recommendations. A national-level, accredited knowledge base is a top requirement for improved end-user systems interpreting these parameters. Finally, categorization using similar, individual characteristics (SNP patterns, exposure history, etc) may be an effective way to predict disease risks, but this approach needs to be concretized and supported with new studies. PMID:25600087

  14. Evaluation and application of a fast module in a PLC based interlock and control system

    NASA Astrophysics Data System (ADS)

    Zaera-Sanz, M.

    2009-08-01

    The LHC Beam Interlock system requires a controller performing a simple matrix function to collect the different beam dump requests. To satisfy the expected safety level of the Interlock, the system should be robust and reliable. The PLC is a promising candidate to fulfil both aspects but too slow to meet the expected response time which is of the order of μseconds. Siemens has introduced a ``so called'' fast module (FM352-5 Boolean Processor). It provides independent and extremely fast control of a process within a larger control system using an onboard processor, a Field Programmable Gate Array (FPGA), to execute code in parallel which results in extremely fast scan times. It is interesting to investigate its features and to evaluate it as a possible candidate for the beam interlock system. This paper publishes the results of this study. As well, this paper could be useful for other applications requiring fast processing using a PLC.

  15. Usability testing of an mHealth device for swallowing therapy in head and neck cancer survivors.

    PubMed

    Constantinescu, Gabriela; Kuffel, Kristina; King, Ben; Hodgetts, William; Rieger, Jana

    2018-04-01

    The objective of this study was to conduct the first patient usability testing of a mobile health (mHealth) system for in-home swallowing therapy. Five participants with a history of head and neck cancer evaluated the mHealth system. After completing an in-application (app) tutorial with the clinician, participants were asked to independently complete five tasks: pair the device to the smartphone, place the device correctly, exercise, interpret progress displays, and close the system. Quantitative and qualitative methods were used to evaluate the effectiveness, efficiency, and satisfaction with the system. Critical changes to the app were found in three of the tasks, resulting in recommendations for the next iteration. These issues were related to ease of Bluetooth pairing, placement of device, and interpretation of statistics. Usability testing with patients identified issues that were essential to address prior to implementing the mHealth system in subsequent clinical trials. Of the usability methods used, video observation (synced screen capture with videoed gestures) revealed the most information.

  16. Evaluation of the effects of a freeze/thaw environment on cellular glass

    NASA Technical Reports Server (NTRS)

    Frickland, P.; Cleland, E.; Hasegawa, T.

    1981-01-01

    Using the evaluation criteria of water vapor permeability and conformability, a protective butylrubber/silicone conformal coating system was selected for use on Foamglas substrates in a freeze/thaw environment. The selection of a specific freeze/thaw cycle which closely models field conditions is discussed. A sampling plan is described which allows independent evaluation of the effects of conformal coatings, cycle number and location within the environmental chamber. The results of visual examination, measurement of density, modulus of rupture and Young's modulus are reported. Based upon statistical evaluation of the experimental results, it is concluded that no degradation in mechanical properties of either coated or uncoated Foamglas occurred within the duration of the test (53 freeze/thaw cycles).

  17. Investment Evaluation of RFID TechnologyApplications: An Evolution Perspective

    NASA Astrophysics Data System (ADS)

    Dimakopoulou, Andriana; Pramatari, Katerina; Karagiannaki, Angeliki; Papadopoulos, George; Paraskevopoulos, Antonis

    Prior empirical research on the evaluation of RFID technologytreats and assesses individual RFID applications independently and in isolation from each other. However, literature on investment evaluation of information technologies has recognised and utilised the significance of evaluating "interdependent" information systems (IS) projects with synergies. Moreover, previous studies when appraising the business value of an RFID investment ignore its opportunity to offer and evolve into additional follow-on investments in the future. Nevertheless, the importance of this notion has been acknowledged by the pertinent literature for the evaluation of other information technologies. This chapter proposes an approach for the investment evaluation of RFID applications considering them rather as a bundle of interdependent and sequential investments than as stand-alone ones. The results from a case study demonstrate how the proposed approach can be employed for the evaluation of RFID projects and offering an additional insight into evaluating investments in RFID applications.

  18. Factors associated with compliance to AHA/ACC performance measures in a myocardial infarction system of care in Brazil.

    PubMed

    Lana, Maria Letícia L; Beaton, Andrea Z; Brant, Luisa C C; Bozzi, Isadora C R S; de Magalhães, Osias; Castro, Luiz Ricardo de A; da Silva Júnior, Francisco César T; da Silva, José Luiz P; Ribeiro, Antonio Luiz P; Nascimento, Bruno R

    2017-08-01

    To evaluate compliance with American Heart Association/American College of Cardiology (AHA/ACC) performance measures for adults with acute myocardial infarction (AMI) and to investigate the factors associated with compliance, in an AMI System of Care in Brazil. Observational longitudinal study. A high-complexity University Hospital, part of the AMI System of Care implemented in Belo Horizonte, Brazil, in 2010. Of note, 1129 patients with ST-elevation myocardial infarction (STEMI) and non-ST-elevation myocardial infarction (NSTEMI) admitted to a single center over 36 months (between 2011 and 2014). Compliance with 13 pre-specified AHA/ACC AMI performance measures was evaluated for patients with AMI, observing exclusion criteria and appropriate numerators and denominators. Median compliance was calculated and variables independently associated with compliance rates were evaluated. Median age was 60 (51/68) years, 67.7% male, 69.8% presented with STEMI and hospital mortality was 8.7%. Median compliance with performance measures was 83% (75/88). Among patients with STEMI, 56% received reperfusion therapy. Overall, 67.3% of patients complied with ≥80% of quality measures. Factors independently associated with better compliance were later date of presentation (semester), likely reflecting ongoing training (OR = 1.19, 95% CI: 1.10-1.28, P < 0.001), male gender (OR = 1.33, 95% CI: 1.00-1.76, P < 0.046), Killip I/II on admission (OR = 1.95, 95% CI: 1.36-2.80, P < 0.001) and diagnosis of NSTEMI (OR = 5.0, 95% CI: 3.51-7.11, P < 0.001). Compliance with AHA/ACC AMI performance measures remains below target in Brazil, but the time trends observed suggest improvement. Continuing education, reduction of system delays and prioritizing high-risk groups are needed to optimize AMI systems of care and improve patient outcomes. © The Author 2017. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  19. 14 CFR 23.953 - Fuel system independence.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel system independence. 23.953 Section 23... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.953 Fuel system independence. (a) Each fuel system for a multiengine airplane must be arranged so that...

  20. 14 CFR 27.953 - Fuel system independence.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel system independence. 27.953 Section 27... AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.953 Fuel system independence. (a) Each fuel system for multiengine rotorcraft must allow fuel to be supplied to each engine through a...

  1. 14 CFR 27.953 - Fuel system independence.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system independence. 27.953 Section 27... AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.953 Fuel system independence. (a) Each fuel system for multiengine rotorcraft must allow fuel to be supplied to each engine through a...

  2. 14 CFR 23.953 - Fuel system independence.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel system independence. 23.953 Section 23... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.953 Fuel system independence. (a) Each fuel system for a multiengine airplane must be arranged so that...

  3. 14 CFR 23.953 - Fuel system independence.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel system independence. 23.953 Section 23... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.953 Fuel system independence. (a) Each fuel system for a multiengine airplane must be arranged so that...

  4. 14 CFR 27.953 - Fuel system independence.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel system independence. 27.953 Section 27... AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.953 Fuel system independence. (a) Each fuel system for multiengine rotorcraft must allow fuel to be supplied to each engine through a...

  5. 14 CFR 27.953 - Fuel system independence.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel system independence. 27.953 Section 27... AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.953 Fuel system independence. (a) Each fuel system for multiengine rotorcraft must allow fuel to be supplied to each engine through a...

  6. 14 CFR 23.953 - Fuel system independence.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system independence. 23.953 Section 23... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.953 Fuel system independence. (a) Each fuel system for a multiengine airplane must be arranged so that...

  7. 14 CFR 23.953 - Fuel system independence.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel system independence. 23.953 Section 23... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.953 Fuel system independence. (a) Each fuel system for a multiengine airplane must be arranged so that...

  8. 14 CFR 27.953 - Fuel system independence.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel system independence. 27.953 Section 27... AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.953 Fuel system independence. (a) Each fuel system for multiengine rotorcraft must allow fuel to be supplied to each engine through a...

  9. Clinical evaluation of a novel microfluidic device for epitope-independent enrichment of circulating tumour cells in patients with small cell lung cancer.

    PubMed

    Chudziak, Jakub; Burt, Deborah J; Mohan, Sumitra; Rothwell, Dominic G; Mesquita, Bárbara; Antonello, Jenny; Dalby, Suzanne; Ayub, Mahmood; Priest, Lynsey; Carter, Louise; Krebs, Matthew G; Blackhall, Fiona; Dive, Caroline; Brady, Ged

    2016-01-21

    Circulating tumour cells (CTCs) have potential utility as minimally-invasive biomarkers to aid cancer treatment decision making. However, many current CTC technologies enrich CTCs using specific surface epitopes that do not necessarily reflect CTC heterogeneity. Here we evaluated the epitope-independent Parsortix system which enriches CTCs based on size and rigidity using both healthy normal volunteer blood samples spiked with tumour cells and blood samples from patients with small cell lung cancer (SCLC). Blood samples were maintained unfractionated at room temperature for up to 4 days followed by plasma removal for circulating free DNA (cfDNA) isolation and direct application of the remaining cell component to the Parsortix system. For tumour cells expressing the EpCAM cell surface marker the numbers of spiked cells retained using the Parsortix system and by EpCAM-positive selection using CellSearch® were not significantly different, whereas only the Parsortix system showed strong enrichment of cells with undetectable EpCAM expression. In a pilot clinical study we banked both enriched CTCs as well as plasma from SCLC patient blood samples. Upon retrieval of the banked Parsortix cellular samples we could detect cytokeratin positive CTCs in all 12 SCLC patients tested. Interestingly, processing parallel samples from the same patients by EpCAM enrichment using CellSearch® revealed only 83% (10/12) with cytokeratin positive CTCs indicating the Parsortix system is enriching for EpCAM negative SCLC CTCs. Our combined results indicate the Parsortix system is a valuable tool for combined cfDNA isolation and CTC enrichment that enables CTC analysis to be extended beyond dependence on surface epitopes.

  10. Multiscale Resilience of Complex Systems

    NASA Astrophysics Data System (ADS)

    Tchiguirinskaia, I.; Schertzer, D. J. M.; Giangola-Murzyn, A.; Hoang Cong, T.

    2014-12-01

    We first argue the need for well defined resilience metrics to better evaluate the resilience of complex systems such as (peri-)urban flood management systems. We review both the successes and limitations of resilience metrics in the framework of dynamical systems and their generalization in the framework of the viability theory. We then point out that the most important step to achieve is to define resilience across scales instead of doing it at a given scale. Our preliminary, critical analysis of the series of attempts to define an operational resilience metrics led us to consider a scale invariant metrics based on the scale independent codimension of extreme singularities. Multifractal downscaling of climate scenarios can be considered as a first illustration. We focussed on a flood scenario evaluation method with the help of two singularities γ_s and γ_Max, corresponding respectively to an effective and a probable maximum singularity, that yield an innovative framework to address the issues of flood resilience systems in a scale independent manner. Indeed, the stationarity of the universal multifractal parameters would result into a rather stable value of probable maximum singularity γ_s. By fixing the limit of acceptability for a maximum flood water depth at a given scale, with a corresponding singularity, we effectively fix the threshold of the probable maximum singularity γ_s as a criterion of the flood resilience we accept. Then various scenarios of flood resilient measures could be simulated with the help of Multi-Hydro under upcoming climat scenarios. The scenarios that result in estimates of either γ_Max or γ_s below the pre-selected γ_s value will assure the effective flood resilience of the whole modeled system across scales. The research for this work was supported, in part, by the EU FP7 SMARTesT and INTERREG IVB RainGain projects.

  11. Speaker identification for the improvement of the security communication between law enforcement units

    NASA Astrophysics Data System (ADS)

    Tovarek, Jaromir; Partila, Pavol

    2017-05-01

    This article discusses the speaker identification for the improvement of the security communication between law enforcement units. The main task of this research was to develop the text-independent speaker identification system which can be used for real-time recognition. This system is designed for identification in the open set. It means that the unknown speaker can be anyone. Communication itself is secured, but we have to check the authorization of the communication parties. We have to decide if the unknown speaker is the authorized for the given action. The calls are recorded by IP telephony server and then these recordings are evaluate using classification If the system evaluates that the speaker is not authorized, it sends a warning message to the administrator. This message can detect, for example a stolen phone or other unusual situation. The administrator then performs the appropriate actions. Our novel proposal system uses multilayer neural network for classification and it consists of three layers (input layer, hidden layer, and output layer). A number of neurons in input layer corresponds with the length of speech features. Output layer then represents classified speakers. Artificial Neural Network classifies speech signal frame by frame, but the final decision is done over the complete record. This rule substantially increases accuracy of the classification. Input data for the neural network are a thirteen Mel-frequency cepstral coefficients, which describe the behavior of the vocal tract. These parameters are the most used for speaker recognition. Parameters for training, testing and validation were extracted from recordings of authorized users. Recording conditions for training data correspond with the real traffic of the system (sampling frequency, bit rate). The main benefit of the research is the system developed for text-independent speaker identification which is applied to secure communication between law enforcement units.

  12. Need and availability of assistive devices to compensate for impaired hand function of individuals with tetraplegia.

    PubMed

    Wäckerlin, Stephanie; Gemperli, Armin; Sigrist-Nix, Diana; Arnet, Ursina

    2018-06-04

    Context/Objective To evaluate the availability and self-declared unmet need of assistive devices to compensate for impaired hand function of individuals with tetraplegia in Switzerland. Design Cross-sectional survey. Setting Community. Participants Individuals with tetraplegia, aged 16 years or older, living in Switzerland. Interventions not applicable. Outcome Measures The self-report availability and unmet need of 18 assistive devices for impaired hand function was analyzed descriptively. The availability of devices was further evaluated stratified by sex, age, SCI severity, independence in grooming, time since injury, living situation, working status, and income. Associations between availability of devices and person characteristics were investigated using logistic regression analysis. Results Overall 32.7% of participants had any assistive device for impaired hand function at their disposal. The most frequent devices were adapted cutlery (14.8%), type supports (14.1%), environmental control systems (11.4%), and writing orthosis (10.6%). In the bivariate analysis several factors showed significant associations with at least one assistive device. Nevertheless, when controlling for potential confounding in multivariate analysis only independence in grooming (adapted cutlery, environmental control systems, type support, speech recognition software), SCI severity (writing orthosis, type support), and sex (adapted kitchenware) remained significantly associated with the availability of the mentioned assistive devices. The self-declared unmet need was generally low (0.7% - 4.3%), except for adapted kitchenware with a moderate unmet need (8.9%). Conclusion This study indicates that most individuals with tetraplegia in Switzerland are adequately supplied with assistive devices to compensate for impaired hand function. The availability depends mainly on SCI severity and independence in grooming.

  13. Mitochondrial assembly receptor expression is an independent prognosticator for patients with oral tongue squamous cell carcinoma.

    PubMed

    Su, Yan-Ye; Chen, Chang-Han; Chien, Chih-Yen; Lin, Wei-Che; Huang, Wan-Ting; Li, Shau-Hsuan

    2017-01-01

    Recent evidence suggests that the local renin-angiotensin system has been implicated in various malignancies. The mitochondrial assembly receptor is a newly identified receptor for angiotensin peptides, angiotensin-(1-7), and has an important role in the renin-angiotensin system. However, the role of the mitochondrial assembly receptor in the prognosis of cancer patients remains unclear. The aim of this study was to evaluate the significance of mitochondrial assembly receptor signaling in the prognosis of oral tongue squamous cell carcinoma. Mitochondrial assembly receptor immunohistochemistry was examined in 151 oral tongue squamous cell carcinoma patients and was correlated with treatment outcome. The functional relevance of the mitochondrial assembly receptor in oral tongue squamous cell carcinoma cell lines was evaluated by 3-(4,5-dimethylthiazole-2-yl)-2,5-diphenyltetrazolium bromide reduction and bromodeoxyuridine incorporation assays. Mitochondrial assembly receptor overexpression was significantly correlated with early pathological T classification ( p=0.029) and the absence of extracapsular spread ( p=0.039). Univariate analyses demonstrated that mitochondrial assembly receptor overexpression was significantly associated with superior overall survival ( p=0.012). In multivariate comparison, mitochondrial assembly receptor overexpression remained independently associated with superior overall survival ( p=0.008, hazard ratio=1.862). In vitro, angiotensin-(1-7) suppressed the cell growth in oral tongue squamous cell carcinoma cells, and this response was reversed by the mitochondrial assembly receptor antagonist, A779. Mitochondrial assembly receptor expression is independently associated with the prognosis of oral tongue squamous cell carcinoma patients. These findings suggest that mitochondrial assembly receptor signaling may be a promising novel target for oral tongue squamous cell carcinoma.

  14. Inflammation-based prognostic score and number of lymph node metastases are independent prognostic factors in esophageal squamous cell carcinoma.

    PubMed

    Kobayashi, Takashi; Teruya, Masanori; Kishiki, Tomokazu; Kaneko, Susumu; Endo, Daisuke; Takenaka, Yoshiharu; Miki, Kenji; Kobayashi, Kaoru; Morita, Koji

    2010-08-01

    Few studies have investigated whether the Glasgow Prognostic Score (GPS), an inflammation-based prognostic score, is useful for postoperative prognosis of esophageal squamous cell carcinoma. GPS was calculated on the basis of admission data as follows: patients with elevated C-reactive protein level (>10 mg/l) and hypoalbuminemia (<35 g/l) were assigned to GPS2. Patients with one or no abnormal value were assigned to GPS1 or GPS0. A new scoring system was constructed using independent prognostic variables and was evaluated on whether it could be used to dictate the choice of clinical options. 65 patients with esophageal squamous cell carcinoma were enrolled. GPS and the number of lymph node metastases were found to be independent prognostic variables. The scoring system comprising GPS and the number of lymph node metastases was found to be effective in the prediction of a long-term outcome (p < 0.0001). Preoperative GPS may be useful for postoperative prognosis of patients with esophageal squamous cell carcinoma. GPS and the number of lymph node metastases could be used to identify a subgroup of patients with esophageal squamous cell carcinoma who are eligible for radical resection but show poor prognosis.

  15. 77 FR 60482 - Yankee Atomic Electric Company; Yankee Rowe Independent Spent Fuel Storage Installation, Staff...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-03

    ... Company; Yankee Rowe Independent Spent Fuel Storage Installation, Staff Evaluation; Exemption 1.0... exemption requests, the NRC staff believes that YAEC should be granted exemptions from the following.... Additional information regarding the NRC (staff) evaluation is documented in a Safety Evaluation Report that...

  16. 77 FR 33005 - Connecticut Yankee Atomic Power Company; Haddam Neck Independent Spent Fuel Storage Installation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-04

    ... Atomic Power Company; Haddam Neck Independent Spent Fuel Storage Installation, Staff Evaluation... requests, the staff determined CYAPCO should be granted exemptions from the following requirements: 10 CFR... regarding the NRC staff evaluation is documented in a Safety Evaluation Report that contains Sensitive...

  17. 75 FR 11161 - Combined Notice of Filings #1

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-10

    ... Generator Interconnection Agreement among SES Solar One, LLC et al. Filed Date: 02/25/2010. Accession Number... System Operator Inc. Description: New York Independent System Operator, Inc submits proposed revisions to... Independent Transmission System Operator Inc. Description: Midwest Independent Transmission System Operator...

  18. An Independent Human Factors Analysis and Evaluation of the Emergency Medical Protocol Checklist for the International Space Station

    NASA Technical Reports Server (NTRS)

    Marshburn, Thomas; Whitmore, Mihriban; Ortiz, Rosie; Segal, Michele; Smart, Kieran; Hughes, Catherine

    2003-01-01

    Emergency medical capabilities aboard the ISS include a Crew Medical Officer (CMO) (not necessarily a physician), and back-up, resuscitation equipment, and a medical checklist. It is essential that CMOs have reliable, usable and informative medical protocols that can be carried out independently in flight. The study evaluates the existing ISS Medical Checklist layout against a checklist updated to reflect a human factors approach to structure and organization. Method: The ISS Medical checklist was divided into non-emergency and emergency sections, and re-organized based on alphabetical and a body systems approach. A desk-top evaluation examined the ability of subjects to navigate to specific medical problems identified as representative of likely non-emergency events. A second evaluation aims to focus on the emergency section of the Medical Checklist, based on the preliminary findings of the first. The final evaluation will use Astronaut CMOs as subjects comparing the original checklist against the updated layout in the task of caring for a "downed crewmember" using a Human Patient Simulator [Medical Education Technologies, Inc.]. Results: Initial results have demonstrated a clear improvement of the re-organized sections to determine the solution to the medical problems. There was no distinct advantage for either alternative, although subjects stated having a preference for the body systems approach. In the second evaluation, subjects will be asked to identify emergency medical conditions, with measures including correct diagnosis, time to completion and solution strategy. The third evaluation will compare the original and fully updated checklists in clinical situations. Conclusions: Initial findings indicate that the ISS Medical Checklist will benefit from a reorganization. The present structure of the checklist has evolved over recent years without systematic testing of crewmember ability to diagnose medical problems. The improvements are expected to enable ISS Crewmembers to more speedily and accurately respond to medical situations on the ISS.

  19. Space station structures development

    NASA Technical Reports Server (NTRS)

    Teller, V. B.

    1986-01-01

    A study of three interrelated tasks focusing on deployable Space Station truss structures is discussed. Task 1, the development of an alternate deployment system for linear truss, resulted in the preliminary design of an in-space reloadable linear motor deployer. Task 2, advanced composites deployable truss development, resulted in the testing and evaluation of composite materials for struts used in a deployable linear truss. Task 3, assembly of structures in space/erectable structures, resulted in the preliminary design of Space Station pressurized module support structures. An independent, redundant support system was developed for the common United States modules.

  20. Assimilation of MODIS and VIIRS AOD to improve aerosols forecasts with FV3-GOCART

    NASA Astrophysics Data System (ADS)

    Pagowski, M.

    2017-12-01

    In 2016 NOAA chose the FV3 dynamical core as a basis for its future global modeling system. We present an implementation of aerosol module in the FV3 model and its assimilation framework. The parameterization of aerosols is based on the GOCART scheme. The assimilation methodology relies on hybrid 3D-Var and EnKF methods. Aerosol observations include aerosol optical depth at 550 nm from VIIRS satellite. Results and evaluation of the system against independent observations and NASA's MERRA-2 is shown.

  1. Three-dimensional vision enhances task performance independently of the surgical method.

    PubMed

    Wagner, O J; Hagen, M; Kurmann, A; Horgan, S; Candinas, D; Vorburger, S A

    2012-10-01

    Within the next few years, the medical industry will launch increasingly affordable three-dimensional (3D) vision systems for the operating room (OR). This study aimed to evaluate the effect of two-dimensional (2D) and 3D visualization on surgical skills and task performance. In this study, 34 individuals with varying laparoscopic experience (18 inexperienced individuals) performed three tasks to test spatial relationships, grasping and positioning, dexterity, precision, and hand-eye and hand-hand coordination. Each task was performed in 3D using binocular vision for open performance, the Viking 3Di Vision System for laparoscopic performance, and the DaVinci robotic system. The same tasks were repeated in 2D using an eye patch for monocular vision, conventional laparoscopy, and the DaVinci robotic system. Loss of 3D vision significantly increased the perceived difficulty of a task and the time required to perform it, independently of the approach (P < 0.0001-0.02). Simple tasks took 25 % to 30 % longer to complete and more complex tasks took 75 % longer with 2D than with 3D vision. Only the difficult task was performed faster with the robot than with laparoscopy (P = 0.005). In every case, 3D robotic performance was superior to conventional laparoscopy (2D) (P < 0.001-0.015). The more complex the task, the more 3D vision accelerates task completion compared with 2D vision. The gain in task performance is independent of the surgical method.

  2. Freva - Freie Univ Evaluation System Framework for Scientific Infrastructures in Earth System Modeling

    NASA Astrophysics Data System (ADS)

    Kadow, Christopher; Illing, Sebastian; Kunst, Oliver; Schartner, Thomas; Kirchner, Ingo; Rust, Henning W.; Cubasch, Ulrich; Ulbrich, Uwe

    2016-04-01

    The Freie Univ Evaluation System Framework (Freva - freva.met.fu-berlin.de) is a software infrastructure for standardized data and tool solutions in Earth system science. Freva runs on high performance computers to handle customizable evaluation systems of research projects, institutes or universities. It combines different software technologies into one common hybrid infrastructure, including all features present in the shell and web environment. The database interface satisfies the international standards provided by the Earth System Grid Federation (ESGF). Freva indexes different data projects into one common search environment by storing the meta data information of the self-describing model, reanalysis and observational data sets in a database. This implemented meta data system with its advanced but easy-to-handle search tool supports users, developers and their plugins to retrieve the required information. A generic application programming interface (API) allows scientific developers to connect their analysis tools with the evaluation system independently of the programming language used. Users of the evaluation techniques benefit from the common interface of the evaluation system without any need to understand the different scripting languages. Facilitation of the provision and usage of tools and climate data automatically increases the number of scientists working with the data sets and identifying discrepancies. The integrated web-shell (shellinabox) adds a degree of freedom in the choice of the working environment and can be used as a gate to the research projects HPC. Plugins are able to integrate their e.g. post-processed results into the database of the user. This allows e.g. post-processing plugins to feed statistical analysis plugins, which fosters an active exchange between plugin developers of a research project. Additionally, the history and configuration sub-system stores every analysis performed with the evaluation system in a database. Configurations and results of the tools can be shared among scientists via shell or web system. Therefore, plugged-in tools benefit from transparency and reproducibility. Furthermore, if configurations match while starting an evaluation plugin, the system suggests to use results already produced by other users - saving CPU/h, I/O, disk space and time. The efficient interaction between different technologies improves the Earth system modeling science framed by Freva.

  3. Freva - Freie Univ Evaluation System Framework for Scientific HPC Infrastructures in Earth System Modeling

    NASA Astrophysics Data System (ADS)

    Kadow, C.; Illing, S.; Schartner, T.; Grieger, J.; Kirchner, I.; Rust, H.; Cubasch, U.; Ulbrich, U.

    2017-12-01

    The Freie Univ Evaluation System Framework (Freva - freva.met.fu-berlin.de) is a software infrastructure for standardized data and tool solutions in Earth system science (e.g. www-miklip.dkrz.de, cmip-eval.dkrz.de). Freva runs on high performance computers to handle customizable evaluation systems of research projects, institutes or universities. It combines different software technologies into one common hybrid infrastructure, including all features present in the shell and web environment. The database interface satisfies the international standards provided by the Earth System Grid Federation (ESGF). Freva indexes different data projects into one common search environment by storing the meta data information of the self-describing model, reanalysis and observational data sets in a database. This implemented meta data system with its advanced but easy-to-handle search tool supports users, developers and their plugins to retrieve the required information. A generic application programming interface (API) allows scientific developers to connect their analysis tools with the evaluation system independently of the programming language used. Users of the evaluation techniques benefit from the common interface of the evaluation system without any need to understand the different scripting languages. The integrated web-shell (shellinabox) adds a degree of freedom in the choice of the working environment and can be used as a gate to the research projects HPC. Plugins are able to integrate their e.g. post-processed results into the database of the user. This allows e.g. post-processing plugins to feed statistical analysis plugins, which fosters an active exchange between plugin developers of a research project. Additionally, the history and configuration sub-system stores every analysis performed with the evaluation system in a database. Configurations and results of the tools can be shared among scientists via shell or web system. Furthermore, if configurations match while starting an evaluation plugin, the system suggests to use results already produced by other users - saving CPU/h, I/O, disk space and time. The efficient interaction between different technologies improves the Earth system modeling science framed by Freva.

  4. Evaluation of bus management options for Independence National Historical Site

    DOT National Transportation Integrated Search

    2000-07-06

    This project analyzes options and identifies preferred designs for a new transportation center in Independence National Historical Park. The Independence Transportation Center will be part of a planned National Constitution Center at Independence Mal...

  5. 14 CFR 25.953 - Fuel system independence.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel system independence. 25.953 Section 25... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.953 Fuel system independence. Each fuel system must meet the requirements of § 25.903(b) by— (a) Allowing the supply of fuel to each...

  6. 14 CFR 29.953 - Fuel system independence.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel system independence. 29.953 Section 29... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.953 Fuel system independence. (a) For category A rotorcraft— (1) The fuel system must meet the requirements of § 29.903(b); and (2...

  7. 14 CFR 29.953 - Fuel system independence.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel system independence. 29.953 Section 29... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.953 Fuel system independence. (a) For category A rotorcraft— (1) The fuel system must meet the requirements of § 29.903(b); and (2...

  8. 14 CFR 25.953 - Fuel system independence.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel system independence. 25.953 Section 25... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.953 Fuel system independence. Each fuel system must meet the requirements of § 25.903(b) by— (a) Allowing the supply of fuel to each...

  9. 14 CFR 29.953 - Fuel system independence.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel system independence. 29.953 Section 29... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.953 Fuel system independence. (a) For category A rotorcraft— (1) The fuel system must meet the requirements of § 29.903(b); and (2...

  10. 14 CFR 29.953 - Fuel system independence.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel system independence. 29.953 Section 29... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.953 Fuel system independence. (a) For category A rotorcraft— (1) The fuel system must meet the requirements of § 29.903(b); and (2...

  11. 14 CFR 25.953 - Fuel system independence.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel system independence. 25.953 Section 25... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.953 Fuel system independence. Each fuel system must meet the requirements of § 25.903(b) by— (a) Allowing the supply of fuel to each...

  12. 14 CFR 29.953 - Fuel system independence.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system independence. 29.953 Section 29... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.953 Fuel system independence. (a) For category A rotorcraft— (1) The fuel system must meet the requirements of § 29.903(b); and (2...

  13. 14 CFR 25.953 - Fuel system independence.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel system independence. 25.953 Section 25... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.953 Fuel system independence. Each fuel system must meet the requirements of § 25.903(b) by— (a) Allowing the supply of fuel to each...

  14. 14 CFR 25.953 - Fuel system independence.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system independence. 25.953 Section 25... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.953 Fuel system independence. Each fuel system must meet the requirements of § 25.903(b) by— (a) Allowing the supply of fuel to each...

  15. Second Line of Defense Megaports Initiative Operational Testing and Evaluation Plan - Kingston Container Terminal, Port of Kingston, Jamaica

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deforest, Thomas J.; VanDyke, Damon S.

    2012-03-01

    Operational Testing and Evaluation Plan - Kingston Container Terminal, Port of Kingston, Jamaica was written for the Second Line of Defense Megaports Initiative. The purpose of the Operational Testing and Evaluation (OT&E) phase of the project is to prepare for turnover of the Megaports system supplied by U.S. Department of Energy/National Nuclear Security Administration (DOE/NNSA) located at the Kingston Container Terminal (KCT) of the Port of Kingston, Jamaica to the Government of Jamaica (GOJ). Activities conducted during the OT&E phase must demonstrate that the Megaports system can be operated effectively in real time by Jamaica Customs and KCT personnel tomore » the satisfaction of the DOE/NNSA. These activities will also determine if the Megaports system, as installed and accepted, is performing according to the Megaports Program objectives such that the system is capable of executing the mission of the Second Line of Defense Megaports Initiative. The OT&E phase of the project also provides an opportunity to consider potential improvements to the system and to take remedial action if performance deficiencies are identified during the course of evaluation. Changes to the system should be considered under an appropriate change-control process. DOE/NNSA will determine that OT&E is complete by examining whether the Megaports system is performing as intended and that the GOJ is fully capable of operating the system independently without continued onsite support from the U.S. team.« less

  16. Peritumoral Artery Scoring System: a Novel Scoring System to Predict Renal Function Outcome after Laparoscopic Partial Nephrectomy.

    PubMed

    Zhang, Ruiyun; Wu, Guangyu; Huang, Jiwei; Shi, Oumin; Kong, Wen; Chen, Yonghui; Xu, Jianrong; Xue, Wei; Zhang, Jin; Huang, Yiran

    2017-06-06

    The present study aimed to assess the impact of peritumoral artery characteristics on renal function outcome prediction using a novel Peritumoral Artery Scoring System based on computed tomography arteriography. Peritumoral artery characteristics and renal function were evaluated in 220 patients who underwent laparoscopic partial nephrectomy and then validate in 51 patients with split and total glomerular filtration rate (GFR). In particular, peritumoral artery classification and diameter were measured to assign arteries into low, moderate, and high Peritumoral Artery Scoring System risk categories. Univariable and multivariable logistic regression analyses were then used to determine risk factors for major renal functional decline. The Peritumoral Artery Scoring System and four other nephrometry systems were compared using receiver operating characteristic curve analysis. The Peritumoral Artery Scoring System was significantly superior to the other systems for predicting postoperative renal function decline (p < 0.001). In receiver operating characteristic analysis, our category system was a superior independent predictor of estimated glomerular filtration rate (eGFR) decline (area-under-the-curve = 0.865, p < 0.001) and total GFR decline (area-under-the-curve = 0.796, p < 0.001), and split GFR decline (area-under-the-curve = 0.841, p < 0.001). Peritumoral artery characteristics were independent predictors of renal function outcome after laparoscopic partial nephrectomy.

  17. Crowd-Sourced Verification of Computational Methods and Data in Systems Toxicology: A Case Study with a Heat-Not-Burn Candidate Modified Risk Tobacco Product.

    PubMed

    Poussin, Carine; Belcastro, Vincenzo; Martin, Florian; Boué, Stéphanie; Peitsch, Manuel C; Hoeng, Julia

    2017-04-17

    Systems toxicology intends to quantify the effect of toxic molecules in biological systems and unravel their mechanisms of toxicity. The development of advanced computational methods is required for analyzing and integrating high throughput data generated for this purpose as well as for extrapolating predictive toxicological outcomes and risk estimates. To ensure the performance and reliability of the methods and verify conclusions from systems toxicology data analysis, it is important to conduct unbiased evaluations by independent third parties. As a case study, we report here the results of an independent verification of methods and data in systems toxicology by crowdsourcing. The sbv IMPROVER systems toxicology computational challenge aimed to evaluate computational methods for the development of blood-based gene expression signature classification models with the ability to predict smoking exposure status. Participants created/trained models on blood gene expression data sets including smokers/mice exposed to 3R4F (a reference cigarette) or noncurrent smokers/Sham (mice exposed to air). Participants applied their models on unseen data to predict whether subjects classify closer to smoke-exposed or nonsmoke exposed groups. The data sets also included data from subjects that had been exposed to potential modified risk tobacco products (MRTPs) or that had switched to a MRTP after exposure to conventional cigarette smoke. The scoring of anonymized participants' predictions was done using predefined metrics. The top 3 performers' methods predicted class labels with area under the precision recall scores above 0.9. Furthermore, although various computational approaches were used, the crowd's results confirmed our own data analysis outcomes with regards to the classification of MRTP-related samples. Mice exposed directly to a MRTP were classified closer to the Sham group. After switching to a MRTP, the confidence that subjects belonged to the smoke-exposed group decreased significantly. Smoking exposure gene signatures that contributed to the group separation included a core set of genes highly consistent across teams such as AHRR, LRRN3, SASH1, and P2RY6. In conclusion, crowdsourcing constitutes a pertinent approach, in complement to the classical peer review process, to independently and unbiasedly verify computational methods and data for risk assessment using systems toxicology.

  18. Energy System and Thermoeconomic Analysis of Combined Heat and Power High Temperature Proton Exchange Membrane Fuel Cell Systems for Light Commercial Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colella, Whitney G.; Pilli, Siva Prasad

    2015-06-01

    The United States (U.S.) Department of Energy (DOE)’s Pacific Northwest National Laboratory (PNNL) is spearheading a program with industry to deploy and independently monitor five kilowatt-electric (kWe) combined heat and power (CHP) fuel cell systems (FCSs) in light commercial buildings. This publication discusses results from PNNL’s research efforts to independently evaluate manufacturer-stated engineering, economic, and environmental performance of these CHP FCSs at installation sites. The analysis was done by developing parameters for economic comparison of CHP installations. Key thermodynamic terms are first defined, followed by an economic analysis using both a standard accounting approach and a management accounting approach. Keymore » economic and environmental performance parameters are evaluated, including (1) the average per unit cost of the CHP FCSs per unit of power, (2) the average per unit cost of the CHP FCSs per unit of energy, (3) the change in greenhouse gas (GHG) and air pollution emissions with a switch from conventional power plants and furnaces to CHP FCSs; (4) the change in GHG mitigation costs from the switch; and (5) the change in human health costs related to air pollution. From the power perspective, the average per unit cost per unit of electrical power is estimated to span a range from $15–19,000/ kilowatt-electric (kWe) (depending on site-specific changes in installation, fuel, and other costs), while the average per unit cost of electrical and heat recovery power varies between $7,000 and $9,000/kW. From the energy perspective, the average per unit cost per unit of electrical energy ranges from $0.38 to $0.46/kilowatt-hour-electric (kWhe), while the average per unit cost per unit of electrical and heat recovery energy varies from $0.18 to $0.23/kWh. These values are calculated from engineering and economic performance data provided by the manufacturer (not independently measured data). The GHG emissions were estimated to decrease by one-third by shifting from a conventional energy system to a CHP FCS system. The GHG mitigation costs were also proportional to the changes in the GHG gas emissions. Human health costs were estimated to decrease significantly with a switch from a conventional system to a CHP FCS system.« less

  19. 14 CFR 121.281 - Fuel system independence.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Fuel system independence. 121.281 Section... REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.281 Fuel system independence. (a) Each airplane fuel system must be arranged so that the failure of any one...

  20. Inferring Meal Eating Activities in Real World Settings from Ambient Sounds: A Feasibility Study

    PubMed Central

    Thomaz, Edison; Zhang, Cheng; Essa, Irfan; Abowd, Gregory D.

    2015-01-01

    Dietary self-monitoring has been shown to be an effective method for weight-loss, but it remains an onerous task despite recent advances in food journaling systems. Semi-automated food journaling can reduce the effort of logging, but often requires that eating activities be detected automatically. In this work we describe results from a feasibility study conducted in-the-wild where eating activities were inferred from ambient sounds captured with a wrist-mounted device; twenty participants wore the device during one day for an average of 5 hours while performing normal everyday activities. Our system was able to identify meal eating with an F-score of 79.8% in a person-dependent evaluation, and with 86.6% accuracy in a person-independent evaluation. Our approach is intended to be practical, leveraging off-the-shelf devices with audio sensing capabilities in contrast to systems for automated dietary assessment based on specialized sensors. PMID:25859566

  1. Evaluation of the effects of one year's operation of the dynamic preferential runway system. [human reactions to overflight air traffic pattern

    NASA Technical Reports Server (NTRS)

    Borsky, P. N.

    1974-01-01

    The FAA introduced an experimental aircraft operations program at JFK Airport called the Dynamic Preferential Runway System (DPRS) in the summer of 1971. The program is designed to distribute air traffic as equally as possible over the surrounding communities, to limit periods of continuous overflight and to vary the same hours of overflight from day to day. After a full year's operation, an evaluation was made of the system's effectiveness. All of the operation's goals were moderately achieved with the greatest relief in reduced overflight afforded the most heavily impacted areas. Few residents, however, were aware of DPRS or felt that it had greatly reduced annoyance or represented a major effort by the aircraft authorities. Statistical analyses of reported annoyance obtained from two independent surveys in 1969 and 1972 reveal limited reductions in annoyance in 1972, with shifts from reported high annoyance to moderate annoyance.

  2. Evaluation of the WHO criteria for the classification of patients with mastocytosis.

    PubMed

    Sánchez-Muñoz, Laura; Alvarez-Twose, Ivan; García-Montero, Andrés C; Teodosio, Cristina; Jara-Acevedo, María; Pedreira, Carlos E; Matito, Almudena; Morgado, Jose Mario T; Sánchez, Maria Luz; Mollejo, Manuela; Gonzalez-de-Olano, David; Orfao, Alberto; Escribano, Luis

    2011-09-01

    Diagnosis and classification of mastocytosis is currently based on the World Health Organization (WHO) criteria. Here, we evaluate the utility of the WHO criteria for the diagnosis and classification of a large series of mastocytosis patients (n=133), and propose a new algorithm that could be routinely applied for refined diagnosis and classification of the disease. Our results confirm the utility of the WHO criteria and provide evidence for the need of additional information for (1) a more precise diagnosis of mastocytosis, (2) specific identification of new forms of the disease, (3) the differential diagnosis between cutaneous mastocytosis vs systemic mastocytosis, and (4) improved distinction between indolent systemic mastocytosis and aggressive systemic mastocytosis. Based on our results, a new algorithm is proposed for a better diagnostic definition and prognostic classification of mastocytosis, as confirmed prospectively in an independent validation series of 117 mastocytosis patients.

  3. Triplet-triplet annihilation photon-upconversion: towards solar energy applications.

    PubMed

    Gray, Victor; Dzebo, Damir; Abrahamsson, Maria; Albinsson, Bo; Moth-Poulsen, Kasper

    2014-06-14

    Solar power production and solar energy storage are important research areas for development of technologies that can facilitate a transition to a future society independent of fossil fuel based energy sources. Devices for direct conversion of solar photons suffer from poor efficiencies due to spectrum losses, which are caused by energy mismatch between the optical absorption of the devices and the broadband irradiation provided by the sun. In this context, photon-upconversion technologies are becoming increasingly interesting since they might offer an efficient way of converting low energy solar energy photons into higher energy photons, ideal for solar power production and solar energy storage. This perspective discusses recent progress in triplet-triplet annihilation (TTA) photon-upconversion systems and devices for solar energy applications. Furthermore, challenges with evaluation of the efficiency of TTA-photon-upconversion systems are discussed and a general approach for evaluation and comparison of existing systems is suggested.

  4. Electronic differential for tramcar bogies: system development and performance evaluation by means of numerical simulation

    NASA Astrophysics Data System (ADS)

    Barbera, Andrea N.; Bucca, Giuseppe; Corradi, Roberto; Facchinetti, Alan; Mapelli, Ferdinando

    2014-05-01

    The dynamic behaviour of railway vehicles depends on the wheelset configuration, i.e. solid axle wheelset or independently rotating wheels (IRWs). The self-centring behaviour, peculiar of the solid axle wheelset, makes this kind of wheelset very suitable for tangent track running at low speed: the absence of the self-centring mechanism in the IRWs may lead to anomalous wheel/rail wear, reduced vehicle safety and passengers' discomfort. On the contrary, during negotiation of the sharp curves typical of urban tramways, solid axle wheelsets produce lateral contact forces higher than those of IRWs. This paper illustrates an electronic differential system to be applied to tramcar bogies equipped with wheel-hub motors which allows switching from solid axle in tangent track to IRWs in sharp curve (and vice versa). An electro-mechanical vehicle model is adopted for the design of the control system and for the evaluation of the vehicle dynamic performances.

  5. Unique methods for on-orbit structural repair, maintenance, and assembly

    NASA Technical Reports Server (NTRS)

    Anderson, Ray; Fuson, Phil

    1994-01-01

    This paper reviews the MDA independent research and development (IRAD) efforts since 1986 in the development of two distinctly different approaches to on-orbit tube repair: (1) one-piece mechanical tube fittings that are forced, under pressure, onto the tube outer surface to effect the repair; and (2) electron beam weldings as demonstrated with the Paton-developed universal hand tool (UHT) space welding system for the repair of fluid lines and tubular components. Other areas of potential on-orbit repair using the UHT include damage to the flat or curved surfaces of habitation modules and truss assemblies. This paper will also address MDA evaluation of the Paton UHT system for on-orbit coating, cleaning, brazing, and cutting of metals. MDA development of an on-orbit compatible nondestructive evaluation (NDE) system for the inspection of tube welds is an important part of this complete space welding capability and will be discussed in a separate paper.

  6. Users' evaluation of the Navy Computer-Assisted Medical Diagnosis System.

    PubMed

    Merrill, L L; Pearsall, D M; Gauker, E D

    1996-01-01

    U.S. Navy Independent Duty Corpsmen (IDCs) aboard small ships and submarines are responsible for all clinical and related health care duties while at sea. During deployment, life-threatening illnesses sometimes require evacuation to a shore-based treatment facility. At-sea evacuations are dangerous, expensive, and may compromise the mission of the vessel. Therefore, Group Medical Officers and IDCs were trained to use the Navy Computer-Assisted Medical Diagnosis (NCAMD) system during deployment. They were then surveyed to evaluate the NCAMD system. Their responses show that NCAMD is a cost-efficient, user-friendly package. It is easy to learn, and is especially valuable for training in the diagnosis of chest and abdominal complaints. However, the delivery of patient care at sea would significantly improve if computer hardware were upgraded to current industry standards. Also, adding various computer peripheral devices, structured forms, and reference materials to the at-sea clinician's resources could enhance shipboard patient care.

  7. SU-E-T-50: A Multi-Institutional Study of Independent Dose Verification Software Program for Lung SBRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawai, D; Takahashi, R; Kamima, T

    2015-06-15

    Purpose: The accuracy of dose distribution depends on treatment planning system especially in heterogeneity-region. The tolerance level (TL) of the secondary check using the independent dose verification may be variable in lung SBRT plans. We conducted a multi-institutional study to evaluate the tolerance level of lung SBRT plans shown in the AAPM TG114. Methods: Five institutes in Japan participated in this study. All of the institutes used a same independent dose verification software program (Simple MU Analysis: SMU, Triangle Product, Ishikawa, JP), which is Clarkson-based and CT images were used to compute radiological path length. Analytical Anisotropic Algorithm (AAA), Pencilmore » Beam Convolution with modified Batho-method (PBC-B) and Adaptive Convolve (AC) were used for lung SBRT planning. A measurement using an ion-chamber was performed in a heterogeneous phantom to compare doses from the three different algorithms and the SMU to the measured dose. In addition to it, a retrospective analysis using clinical lung SBRT plans (547 beams from 77 patients) was conducted to evaluate the confidence limit (CL, Average±2SD) in dose between the three algorithms and the SMU. Results: Compared to the measurement, the AAA showed the larger systematic dose error of 2.9±3.2% than PBC-B and AC. The Clarkson-based SMU showed larger error of 5.8±3.8%. The CLs for clinical plans were 7.7±6.0 % (AAA), 5.3±3.3 % (AC), 5.7±3.4 % (PBC -B), respectively. Conclusion: The TLs from the CLs were evaluated. A Clarkson-based system shows a large systematic variation because of inhomogeneous correction. The AAA showed a significant variation. Thus, we must consider the difference of inhomogeneous correction as well as the dependence of dose calculation engine.« less

  8. Independent Living Evaluation-Training Program. Reprint Series No. 16.

    ERIC Educational Resources Information Center

    Van Soest, Eileen; And Others

    Intended to be used both as a guide for general program direction and as an individual evaluation and training tool this rehabilitation training guide includes materials and evaluation devices for use with mentally and/or physically handicapped clients on basic, intermediate and advanced living center levels. The eight independent living skill…

  9. Plasma Metabolites Predict Severity of Depression and Suicidal Ideation in Psychiatric Patients-A Multicenter Pilot Analysis.

    PubMed

    Setoyama, Daiki; Kato, Takahiro A; Hashimoto, Ryota; Kunugi, Hiroshi; Hattori, Kotaro; Hayakawa, Kohei; Sato-Kasai, Mina; Shimokawa, Norihiro; Kaneko, Sachie; Yoshida, Sumiko; Goto, Yu-Ichi; Yasuda, Yuka; Yamamori, Hidenaga; Ohgidani, Masahiro; Sagata, Noriaki; Miura, Daisuke; Kang, Dongchon; Kanba, Shigenobu

    2016-01-01

    Evaluating the severity of depression (SOD), especially suicidal ideation (SI), is crucial in the treatment of not only patients with mood disorders but also psychiatric patients in general. SOD has been assessed on interviews such as the Hamilton Rating Scale for Depression (HAMD)-17, and/or self-administered questionnaires such as the Patient Health Questionnaire (PHQ)-9. However, these evaluation systems have relied on a person's subjective information, which sometimes lead to difficulties in clinical settings. To resolve this limitation, a more objective SOD evaluation system is needed. Herein, we collected clinical data including HAMD-17/PHQ-9 and blood plasma of psychiatric patients from three independent clinical centers. We performed metabolome analysis of blood plasma using liquid chromatography mass spectrometry (LC-MS), and 123 metabolites were detected. Interestingly, five plasma metabolites (3-hydroxybutyrate (3HB), betaine, citrate, creatinine, and gamma-aminobutyric acid (GABA)) are commonly associated with SOD in all three independent cohort sets regardless of the presence or absence of medication and diagnostic difference. In addition, we have shown several metabolites are independently associated with sub-symptoms of depression including SI. We successfully created a classification model to discriminate depressive patients with or without SI by machine learning technique. Finally, we produced a pilot algorithm to predict a grade of SI with citrate and kynurenine. The above metabolites may have strongly been associated with the underlying novel biological pathophysiology of SOD. We should explore the biological impact of these metabolites on depressive symptoms by utilizing a cross species study model with human and rodents. The present multicenter pilot study offers a potential utility for measuring blood metabolites as a novel objective tool for not only assessing SOD but also evaluating therapeutic efficacy in clinical practice. In addition, modification of these metabolites by diet and/or medications may be a novel therapeutic target for depression. To clarify these aspects, clinical trials measuring metabolites before/after interventions should be conducted. Larger cohort studies including non-clinical subjects are also warranted to clarify our pilot findings.

  10. A Novel System for Supporting Autism Diagnosis Using Home Videos: Iterative Development and Evaluation of System Design.

    PubMed

    Nazneen, Nazneen; Rozga, Agata; Smith, Christopher J; Oberleitner, Ron; Abowd, Gregory D; Arriaga, Rosa I

    2015-06-17

    Observing behavior in the natural environment is valuable to obtain an accurate and comprehensive assessment of a child's behavior, but in practice it is limited to in-clinic observation. Research shows significant time lag between when parents first become concerned and when the child is finally diagnosed with autism. This lag can delay early interventions that have been shown to improve developmental outcomes. To develop and evaluate the design of an asynchronous system that allows parents to easily collect clinically valid in-home videos of their child's behavior and supports diagnosticians in completing diagnostic assessment of autism. First, interviews were conducted with 11 clinicians and 6 families to solicit feedback from stakeholders about the system concept. Next, the system was iteratively designed, informed by experiences of families using it in a controlled home-like experimental setting and a participatory design process involving domain experts. Finally, in-field evaluation of the system design was conducted with 5 families of children (4 with previous autism diagnosis and 1 child typically developing) and 3 diagnosticians. For each family, 2 diagnosticians, blind to the child's previous diagnostic status, independently completed an autism diagnosis via our system. We compared the outcome of the assessment between the 2 diagnosticians, and between each diagnostician and the child's previous diagnostic status. The system that resulted through the iterative design process includes (1) NODA smartCapture, a mobile phone-based application for parents to record prescribed video evidence at home; and (2) NODA Connect, a Web portal for diagnosticians to direct in-home video collection, access developmental history, and conduct an assessment by linking evidence of behaviors tagged in the videos to the Diagnostic and Statistical Manual of Mental Disorders criteria. Applying clinical judgment, the diagnostician concludes a diagnostic outcome. During field evaluation, without prior training, parents easily (average rating of 4 on a 5-point scale) used the system to record video evidence. Across all in-home video evidence recorded during field evaluation, 96% (26/27) were judged as clinically useful, for performing an autism diagnosis. For 4 children (3 with autism and 1 typically developing), both diagnosticians independently arrived at the correct diagnostic status (autism versus typical). Overall, in 91% of assessments (10/11) via NODA Connect, diagnosticians confidently (average rating 4.5 on a 5-point scale) concluded a diagnostic outcome that matched with the child's previous diagnostic status. The in-field evaluation demonstrated that the system's design enabled parents to easily record clinically valid evidence of their child's behavior, and diagnosticians to complete a diagnostic assessment. These results shed light on the potential for appropriately designed telehealth technology to support clinical assessments using in-home video captured by families. This assessment model can be readily generalized to other conditions where direct observation of behavior plays a central role in the assessment process.

  11. Independent evaluation of the transit retrofit package safety applications : final report.

    DOT National Transportation Integrated Search

    2015-02-01

    This report presents the methodology and results of the independent evaluation of retrofit safety packages installed on transit vehicles in the : Safety Pilot Model Deploymentpart of the United States Department of Transportations Intelligent T...

  12. Rehabilitation outcomes in children with cerebral palsy during a 2 year period

    PubMed Central

    İçağasıoğlu, Afitap; Mesci, Erkan; Yumusakhuylu, Yasemin; Turgut, Selin Turan; Murat, Sadiye

    2015-01-01

    [Purpose] To observe motor and functional progress of children with cerebral palsy during 2 years. [Subjects and Methods] Pediatric cerebral palsy patients aged 3–15 years (n = 35/69) with 24-month follow-up at our outpatient cerebral palsy clinic were evaluated retrospectively. The distribution of cerebral palsy types was as follows: diplegia (n = 19), hemiplegia (n = 4), and quadriplegia (n = 12). Participants were divided into 3 groups according to their Gross Motor Functional Classification System scores (i.e., mild, moderate, and severe). All participants were evaluated initially and at the final assessment 2 years later. During this time, patients were treated 3 times/week. Changes in motor and functional abilities were assessed based on Gross Motor Function Measure-88 and Wee Functional Independence Measure. [Results] Significant improvements were observed in Gross Motor Function Measure-88 and Wee Functional Independence Measure results in all 35 patients at the end of 2 years. The Gross Motor Function Measure-88 scores correlated with Wee Functional Independence Measure Scores. Marked increases in motor and functional capabilities in mild and moderate cerebral palsy patients were observed in the subgroup assessments, but not in those with severe cerebral palsy. [Conclusion] Rehabilitation may greatly help mild and moderate cerebral palsy patients achieve their full potential. PMID:26644677

  13. Antenna gain of actively compensated free-space optical communication systems under strong turbulence conditions.

    PubMed

    Juarez, Juan C; Brown, David M; Young, David W

    2014-05-19

    Current Strehl ratio models for actively compensated free-space optical communications terminals do not accurately predict system performance under strong turbulence conditions as they are based on weak turbulence theory. For evaluation of compensated systems, we present an approach for simulating the Strehl ratio with both low-order (tip/tilt) and higher-order (adaptive optics) correction. Our simulation results are then compared to the published models and their range of turbulence validity is assessed. Finally, we propose a new Strehl ratio model and antenna gain equation that are valid for general turbulence conditions independent of the degree of compensation.

  14. A visual surveillance system for person re-identification

    NASA Astrophysics Data System (ADS)

    El-Alfy, Hazem; Muramatsu, Daigo; Teranishi, Yuuichi; Nishinaga, Nozomu; Makihara, Yasushi; Yagi, Yasushi

    2017-03-01

    We attempt the problem of autonomous surveillance for person re-identification. This is an active research area, where most recent work focuses on the open challenges of re-identification, independently of prerequisites of detection and tracking. In this paper, we are interested in designing a complete surveillance system, joining all the pieces of the puzzle together. We start by collecting our own dataset from multiple cameras. Then, we automate the process of detection and tracking of human subjects in the scenes, followed by performing the re-identification task. We evaluate the recognition performance of our system, report its strengths, discuss open challenges and suggest ways to address them.

  15. Independent Living & Disability Policy in the Netherlands: Three Models of Residential Care & Independent Living. Monograph Number Twenty-Seven.

    ERIC Educational Resources Information Center

    DeJong, Gerben

    The monograph examines the way in which the Netherlands' three-part system of residential care and independent living (IL) for people with physical disabilities interacts with the country's health and social welfare systems. The three-part system comprises: the residential center model, the clustered housing model, and the independent housing…

  16. An MRI-Compatible Robotic System With Hybrid Tracking for MRI-Guided Prostate Intervention

    PubMed Central

    Krieger, Axel; Iordachita, Iulian I.; Guion, Peter; Singh, Anurag K.; Kaushal, Aradhana; Ménard, Cynthia; Pinto, Peter A.; Camphausen, Kevin; Fichtinger, Gabor

    2012-01-01

    This paper reports the development, evaluation, and first clinical trials of the access to the prostate tissue (APT) II system—a scanner independent system for magnetic resonance imaging (MRI)-guided transrectal prostate interventions. The system utilizes novel manipulator mechanics employing a steerable needle channel and a novel six degree-of-freedom hybrid tracking method, comprising passive fiducial tracking for initial registration and subsequent incremental motion measurements. Targeting accuracy of the system in prostate phantom experiments and two clinical human-subject procedures is shown to compare favorably with existing systems using passive and active tracking methods. The portable design of the APT II system, using only standard MRI image sequences and minimal custom scanner interfacing, allows the system to be easily used on different MRI scanners. PMID:22009867

  17. Comparison of heuristic and cognitive walkthrough usability evaluation methods for evaluating health information systems.

    PubMed

    Khajouei, Reza; Zahiri Esfahani, Misagh; Jahani, Yunes

    2017-04-01

    There are several user-based and expert-based usability evaluation methods that may perform differently according to the context in which they are used. The objective of this study was to compare 2 expert-based methods, heuristic evaluation (HE) and cognitive walkthrough (CW), for evaluating usability of health care information systems. Five evaluators independently evaluated a medical office management system using HE and CW. We compared the 2 methods in terms of the number of identified usability problems, their severity, and the coverage of each method. In total, 156 problems were identified using the 2 methods. HE identified a significantly higher number of problems related to the "satisfaction" attribute ( P  = .002). The number of problems identified using CW concerning the "learnability" attribute was significantly higher than those identified using HE ( P  = .005). There was no significant difference between the number of problems identified by HE, based on different usability attributes ( P  = .232). Results of CW showed a significant difference between the number of problems related to usability attributes ( P  < .0001). The average severity of problems identified using CW was significantly higher than that of HE ( P  < .0001). This study showed that HE and CW do not differ significantly in terms of the number of usability problems identified, but they differ based on the severity of problems and the coverage of some usability attributes. The results suggest that CW would be the preferred method for evaluating systems intended for novice users and HE for users who have experience with similar systems. However, more studies are needed to support this finding. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  18. Evaluation of the National Research Council (2001) dairy model and derivation of new prediction equations. 1. Digestibility of fiber, fat, protein, and nonfiber carbohydrate.

    PubMed

    White, R R; Roman-Garcia, Y; Firkins, J L; VandeHaar, M J; Armentano, L E; Weiss, W P; McGill, T; Garnett, R; Hanigan, M D

    2017-05-01

    Evaluation of ration balancing systems such as the National Research Council (NRC) Nutrient Requirements series is important for improving predictions of animal nutrient requirements and advancing feeding strategies. This work used a literature data set (n = 550) to evaluate predictions of total-tract digested neutral detergent fiber (NDF), fatty acid (FA), crude protein (CP), and nonfiber carbohydrate (NFC) estimated by the NRC (2001) dairy model. Mean biases suggested that the NRC (2001) lactating cow model overestimated true FA and CP digestibility by 26 and 7%, respectively, and under-predicted NDF digestibility by 16%. All NRC (2001) estimates had notable mean and slope biases and large root mean squared prediction error (RMSPE), and concordance (CCC) ranged from poor to good. Predicting NDF digestibility with independent equations for legumes, corn silage, other forages, and nonforage feeds improved CCC (0.85 vs. 0.76) compared with the re-derived NRC (2001) equation form (NRC equation with parameter estimates re-derived against this data set). Separate FA digestion coefficients were derived for different fat supplements (animal fats, oils, and other fat types) and for the basal diet. This equation returned improved (from 0.76 to 0.94) CCC compared with the re-derived NRC (2001) equation form. Unique CP digestibility equations were derived for forages, animal protein feeds, plant protein feeds, and other feeds, which improved CCC compared with the re-derived NRC (2001) equation form (0.74 to 0.85). New NFC digestibility coefficients were derived for grain-specific starch digestibilities, with residual organic matter assumed to be 98% digestible. A Monte Carlo cross-validation was performed to evaluate repeatability of model fit. In this procedure, data were randomly subsetted 500 times into derivation (60%) and evaluation (40%) data sets, and equations were derived using the derivation data and then evaluated against the independent evaluation data. Models derived with random study effects demonstrated poor repeatability of fit in independent evaluation. Similar equations derived without random study effects showed improved fit against independent data and little evidence of biased parameter estimates associated with failure to include study effects. The equations derived in this analysis provide interesting insight into how NDF, starch, FA, and CP digestibilities are affected by intake, feed type, and diet composition. The Authors. Published by the Federation of Animal Science Societies and Elsevier Inc. on behalf of the American Dairy Science Association®. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).

  19. A Personalized Self-Management Rehabilitation System with an Intelligent Shoe for Stroke Survivors: A Realist Evaluation

    PubMed Central

    2016-01-01

    Background In the United Kingdom, stroke is the most significant cause of adult disability. Stroke survivors are frequently left with physical and psychological changes that can profoundly affect their functional ability, independence, and social participation. Research suggests that long-term, intense, task- and context-specific rehabilitation that is goal-oriented and environmentally enriched improves function, independence, and quality of life after a stroke. It is recommended that rehabilitation should continue until maximum recovery has been achieved. However, the increasing demand on services and financial constraints means that needs cannot be met through traditional face-to-face delivery of rehabilitation. Using a participatory design methodology, we developed an information communication technology–enhanced Personalized Self-Managed rehabilitation System (PSMrS) for stroke survivors with integrated insole sensor technology within an “intelligent shoe.”. The intervention model was based around a rehabilitation paradigm underpinned by theories of motor relearning and neuroplastic adaptation, motivational feedback, self-efficacy, and knowledge transfer. Objective To understand the conditions under which this technology-based rehabilitation solution would most likely have an impact on the motor behavior of the user, what would work for whom, in what context, and how. We were interested in what aspects of the system would work best to facilitate the motor behavior change associated with self-managed rehabilitation and which user characteristics and circumstances of use could promote improved functional outcomes. Methods We used a Realist Evaluation (RE) framework to evaluate the final prototype PSMrS with the assumption that the intervention consists of a series of configurations that include the Context of use, the underlying Mechanisms of change and the potential Outcomes or impacts (CMOs). We developed the CMOs from literature reviews and engagement with clinicians, users, and caregivers during a series of focus groups and home visits. These CMOs were then tested in five in-depth case studies with stroke survivors and their caregivers. Results While two new propositions emerged, the second importantly related to the self-management aspects of the system. The study revealed that the system should also encourage independent use and the setting of personalized goals or activities. Conclusions Information communication technology that purports to support the self-management of stroke rehabilitation should give significant consideration to the need for motivational feedback that provides quantitative, reliable, accurate, context-specific, and culturally sensitive information about the achievement of personalized goal-based activities. PMID:28582250

  20. A Personalized Self-Management Rehabilitation System with an Intelligent Shoe for Stroke Survivors: A Realist Evaluation.

    PubMed

    Mawson, Susan; Nasr, Nasrin; Parker, Jack; Davies, Richard; Zheng, Huiru; Mountain, Gail

    2016-01-07

    In the United Kingdom, stroke is the most significant cause of adult disability. Stroke survivors are frequently left with physical and psychological changes that can profoundly affect their functional ability, independence, and social participation. Research suggests that long-term, intense, task- and context-specific rehabilitation that is goal-oriented and environmentally enriched improves function, independence, and quality of life after a stroke. It is recommended that rehabilitation should continue until maximum recovery has been achieved. However, the increasing demand on services and financial constraints means that needs cannot be met through traditional face-to-face delivery of rehabilitation. Using a participatory design methodology, we developed an information communication technology-enhanced Personalized Self-Managed rehabilitation System (PSMrS) for stroke survivors with integrated insole sensor technology within an "intelligent shoe.". The intervention model was based around a rehabilitation paradigm underpinned by theories of motor relearning and neuroplastic adaptation, motivational feedback, self-efficacy, and knowledge transfer. To understand the conditions under which this technology-based rehabilitation solution would most likely have an impact on the motor behavior of the user, what would work for whom, in what context, and how. We were interested in what aspects of the system would work best to facilitate the motor behavior change associated with self-managed rehabilitation and which user characteristics and circumstances of use could promote improved functional outcomes. We used a Realist Evaluation (RE) framework to evaluate the final prototype PSMrS with the assumption that the intervention consists of a series of configurations that include the Context of use, the underlying Mechanisms of change and the potential Outcomes or impacts (CMOs). We developed the CMOs from literature reviews and engagement with clinicians, users, and caregivers during a series of focus groups and home visits. These CMOs were then tested in five in-depth case studies with stroke survivors and their caregivers. While two new propositions emerged, the second importantly related to the self-management aspects of the system. The study revealed that the system should also encourage independent use and the setting of personalized goals or activities. Information communication technology that purports to support the self-management of stroke rehabilitation should give significant consideration to the need for motivational feedback that provides quantitative, reliable, accurate, context-specific, and culturally sensitive information about the achievement of personalized goal-based activities. ©Susan Mawson, Nasrin Nasr, Jack Parker, Richard Davies, Huiri Zheng, Gail Mountain. Originally published in JMIR Rehabilitation and Assistive Technology (http://rehab.jmir.org), 07.01.2016.

  1. Z{gamma}{gamma}{gamma} {yields} 0 Processes in SANC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bardin, D. Yu., E-mail: bardin@nu.jinr.ru; Kalinovskaya, L. V., E-mail: kalinov@nu.jinr.ru; Uglov, E. D., E-mail: corner@nu.jinr.ru

    2013-11-15

    We describe the analytic and numerical evaluation of the {gamma}{gamma} {yields} {gamma}Z process cross section and the Z {yields} {gamma}{gamma}{gamma} decay rate within the SANC system multi-channel approach at the one-loop accuracy level with all masses taken into account. The corresponding package for numeric calculations is presented. For checking of the results' correctness we make a comparison with the other independent calculations.

  2. [Laboratory unification: advantages and disadvantages for clinical microbiology].

    PubMed

    Andreu, Antonia; Matas, Lurdes

    2010-10-01

    This article aims to reflect on which areas or tasks of microbiology laboratories could be unified with those of clinical biochemistry, hematology, immunology or pathology laboratories to benefit patients and the health system, as well as the areas that should remain independent since their amalgamation would not only fail to provide a benefit but could even jeopardize the quality of microbiological diagnosis, and consequently patient care. To do this, the distinct analytic phases of diagnosis are analyzed, and the advantages and disadvantages of amalgamation are evaluated in each phase. The pros and cons of the unification of certain areas such as the computer system, occupational risk units, customer service, purchasing logistics, and materials storage, etc, are also discussed. Lastly, the effect of unification on urgent microbiology diagnosis is analyzed. Microbiological diagnosis should be unique. The microbiologist should perform an overall evaluation of the distinct techniques used for a particular patient, both those that involve direct diagnosis (staining, culture, antigen detection techniques or molecular techniques) and indirect diagnosis (antibody detection). Moreover, the microbiology laboratory should be independent, with highly trained technicians and specialists in microbiology that provide added value as experts in infection and as key figures in the process of establishing a correct etiological diagnosis. Copyright © 2010 Elsevier España S.L. All rights reserved.

  3. Assessing the impacts of assimilating IASI and MOPITT CO retrievals using CESM-CAM-chem and DART

    NASA Astrophysics Data System (ADS)

    Barré, Jérôme; Gaubert, Benjamin; Arellano, Avelino F. J.; Worden, Helen M.; Edwards, David P.; Deeter, Merritt N.; Anderson, Jeffrey L.; Raeder, Kevin; Collins, Nancy; Tilmes, Simone; Francis, Gene; Clerbaux, Cathy; Emmons, Louisa K.; Pfister, Gabriele G.; Coheur, Pierre-François; Hurtmans, Daniel

    2015-10-01

    We show the results and evaluation with independent measurements from assimilating both MOPITT (Measurements Of Pollution In The Troposphere) and IASI (Infrared Atmospheric Sounding Interferometer) retrieved profiles into the Community Earth System Model (CESM). We used the Data Assimilation Research Testbed ensemble Kalman filter technique, with the full atmospheric chemistry CESM component Community Atmospheric Model with Chemistry. We first discuss the methodology and evaluation of the current data assimilation system with coupled meteorology and chemistry data assimilation. The different capabilities of MOPITT and IASI retrievals are highlighted, with particular attention to instrument vertical sensitivity and coverage and how these impact the analyses. MOPITT and IASI CO retrievals mostly constrain the CO fields close to the main anthropogenic, biogenic, and biomass burning CO sources. In the case of IASI CO assimilation, we also observe constraints on CO far from the sources. During the simulation time period (June and July 2008), CO assimilation of both instruments strongly improves the atmospheric CO state as compared to independent observations, with the higher spatial coverage of IASI providing better results on the global scale. However, the enhanced sensitivity of multispectral MOPITT observations to near surface CO over the main source regions provides synergistic effects at regional scales.

  4. Interaction of feel system and flight control system dynamics on lateral flying qualities

    NASA Technical Reports Server (NTRS)

    Bailey, Randall E.; Powers, Bruce G.; Shafer, Mary F.

    1988-01-01

    An investigation of feel system and flight control system dynamics on lateral flying qualities was conducted using the variable stability USAF NT-33 aircraft. Experimental variations in feel system natural frequency, force-deflection gradient, control system command architecture type, flight control system filter frequency, and control system delay were made. The experiment data include pilot ratings using the Cooper-Harper (1969) rating scale, pilot comments, and tracking performance statistic. Three test pilots served as evaluators. The data indicate that as the feel system natural frequency is reduced lateral flying qualities degrade. At the slowest feel system frequency, the closed-loop response becomes nonlinear with a 'bobweight' effect apparent in the feel system. Feel system influences were essentially independent of the control system architecture. The flying qualities influence due to the feel system was different than when the identical dynamic systenm was used as a flight control system element.

  5. SU-F-T-267: A Clarkson-Based Independent Dose Verification for the Helical Tomotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nagata, H; Juntendo University, Hongo, Tokyo; Hongo, H

    2016-06-15

    Purpose: There have been few reports for independent dose verification for Tomotherapy. We evaluated the accuracy and the effectiveness of an independent dose verification system for the Tomotherapy. Methods: Simple MU Analysis (SMU, Triangle Product, Ishikawa, Japan) was used as the independent verification system and the system implemented a Clarkson-based dose calculation algorithm using CT image dataset. For dose calculation in the SMU, the Tomotherapy machine-specific dosimetric parameters (TMR, Scp, OAR and MLC transmission factor) were registered as the machine beam data. Dose calculation was performed after Tomotherapy sinogram from DICOM-RT plan information was converted to the information for MUmore » and MLC location at more segmented control points. The performance of the SMU was assessed by a point dose measurement in non-IMRT and IMRT plans (simple target and mock prostate plans). Subsequently, 30 patients’ treatment plans for prostate were compared. Results: From the comparison, dose differences between the SMU and the measurement were within 3% for all cases in non-IMRT plans. In the IMRT plan for the simple target, the differences (Average±1SD) were −0.70±1.10% (SMU vs. TPS), −0.40±0.10% (measurement vs. TPS) and −1.20±1.00% (measurement vs. SMU), respectively. For the mock prostate, the differences were −0.40±0.60% (SMU vs. TPS), −0.50±0.90% (measurement vs. TPS) and −0.90±0.60% (measurement vs. SMU), respectively. For patients’ plans, the difference was −0.50±2.10% (SMU vs. TPS). Conclusion: A Clarkson-based independent dose verification for the Tomotherapy can be clinically available as a secondary check with the similar tolerance level of AAPM Task group 114. This research is partially supported by Japan Agency for Medical Research and Development (AMED)« less

  6. Commercial Building Energy Asset Score System: Program Overview and Technical Protocol (Version 1.0)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Na; Gorrissen, Willy J.

    2013-01-11

    The U.S. Department of Energy (DOE) is developing a national voluntary energy asset score system that includes an energy asset score tool to help building owners evaluate their buildings with respect to the score system. The goal of the energy asset score system is to facilitate cost-effective investment in energy efficiency improvements of commercial buildings. The system will allow building owners and managers to compare their building infrastructure against peers and track building upgrade progress over time. The system can also help other building stakeholders (e.g., building operators, tenants, financiers, and appraisers) understand the relative efficiency of different buildings inmore » a way that is independent from their operations and occupancy. This report outlines the technical protocol used to generate the energy asset score, explains the scoring methodology, and provides additional details regarding the energy asset score tool. This report also describes alternative methods that were considered prior to developing the current approach. Finally, this report describes a few features of the program where alternative approaches are still under evaluation.« less

  7. The Interagency Nuclear Safety Review Panel's Galileo safety evaluation report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, R.C.; Gray, L.B.; Huff, D.A.

    The safety evaluation report (SER) for Galileo was prepared by the Interagency Nuclear Safety Review Panel (INSRP) coordinators in accordance with Presidential directive/National Security Council memorandum 25. The INSRP consists of three coordinators appointed by their respective agencies, the Department of Defense, the Department of Energy (DOE), and the National Aeronautics and Space Administration (NASA). These individuals are independent of the program being evaluated and depend on independent experts drawn from the national technical community to serve on the five INSRP subpanels. The Galileo SER is based on input provided by the NASA Galileo Program Office, review and assessment ofmore » the final safety analysis report prepared by the Office of Special Applications of the DOE under a memorandum of understanding between NASA and the DOE, as well as other related data and analyses. The SER was prepared for use by the agencies and the Office of Science and Technology Policy, Executive Office of the Present for use in their launch decision-making process. Although more than 20 nuclear-powered space missions have been previously reviewed via the INSRP process, the Galileo review constituted the first review of a nuclear power source associated with launch aboard the Space Transportation System.« less

  8. Speeding up tsunami wave propagation modeling

    NASA Astrophysics Data System (ADS)

    Lavrentyev, Mikhail; Romanenko, Alexey

    2014-05-01

    Trans-oceanic wave propagation is one of the most time/CPU consuming parts of the tsunami modeling process. The so-called Method Of Splitting Tsunami (MOST) software package, developed at PMEL NOAA USA (Pacific Marine Environmental Laboratory of the National Oceanic and Atmospheric Administration, USA), is widely used to evaluate the tsunami parameters. However, it takes time to simulate trans-ocean wave propagation, that is up to 5 hours CPU time to "drive" the wave from Chili (epicenter) to the coast of Japan (even using a rather coarse computational mesh). Accurate wave height prediction requires fine meshes which leads to dramatic increase in time for simulation. Computation time is among the critical parameter as it takes only about 20 minutes for tsunami wave to approach the coast of Japan after earthquake at Japan trench or Sagami trench (as it was after the Great East Japan Earthquake on March 11, 2011). MOST solves numerically the hyperbolic system for three unknown functions, namely velocity vector and wave height (shallow water approximation). The system could be split into two independent systems by orthogonal directions (splitting method). Each system can be treated independently. This calculation scheme is well suited for SIMD architecture and GPUs as well. We performed adaptation of MOST package to GPU. Several numerical tests showed 40x performance gain for NVIDIA Tesla C2050 GPU vs. single core of Intel i7 processor. Results of numerical experiments were compared with other available simulation data. Calculation results, obtained at GPU, differ from the reference ones by 10^-3 cm of the wave height simulating 24 hours wave propagation. This allows us to speak about possibility to develop real-time system for evaluating tsunami danger.

  9. Rigorous accuracy assessment for 3D reconstruction using time-series Dual Fluoroscopy (DF) image pairs

    NASA Astrophysics Data System (ADS)

    Al-Durgham, Kaleel; Lichti, Derek D.; Kuntze, Gregor; Ronsky, Janet

    2017-06-01

    High-speed biplanar videoradiography, or clinically referred to as dual fluoroscopy (DF), imaging systems are being used increasingly for skeletal kinematics analysis. Typically, a DF system comprises two X-ray sources, two image intensifiers and two high-speed video cameras. The combination of these elements provides time-series image pairs of articulating bones of a joint, which permits the measurement of bony rotation and translation in 3D at high temporal resolution (e.g., 120-250 Hz). Assessment of the accuracy of 3D measurements derived from DF imaging has been the subject of recent research efforts by several groups, however with methodological limitations. This paper presents a novel and simple accuracy assessment procedure based on using precise photogrammetric tools. We address the fundamental photogrammetry principles for the accuracy evaluation of an imaging system. Bundle adjustment with selfcalibration is used for the estimation of the system parameters. The bundle adjustment calibration uses an appropriate sensor model and applies free-network constraints and relative orientation stability constraints for a precise estimation of the system parameters. A photogrammetric intersection of time-series image pairs is used for the 3D reconstruction of a rotating planar object. A point-based registration method is used to combine the 3D coordinates from the intersection and independently surveyed coordinates. The final DF accuracy measure is reported as the distance between 3D coordinates from image intersection and the independently surveyed coordinates. The accuracy assessment procedure is designed to evaluate the accuracy over the full DF image format and a wide range of object rotation. Experiment of reconstruction of a rotating planar object reported an average positional error of 0.44 +/- 0.2 mm in the derived 3D coordinates (minimum 0.05 and maximum 1.2 mm).

  10. U-Th age evidence from carbonate veins for episodic crustal deformation of Central Anatolian Volcanic Province

    NASA Astrophysics Data System (ADS)

    Karabacak, Volkan; Uysal, I. Tonguç; Ünal-İmer, Ezgi; Mutlu, Halim; Zhao, Jian-xin

    2017-12-01

    Central Anatolia represents one of the most outstanding examples of intraplate deformation related to both continental collision and back-arc extension generating non-uniformly distributed stress fields. In this study, we provide direct field evidence of various stress directions and investigate carbonate-filled fracture systems in the Central Anatolian Volcanic Province using U/Th geochronology and isotope geochemistry for evaluating the episodes of latest volcanic activity under regional stress. Field data reveal two independent fracture systems in the region. Successive fracture development has been controlled by two different volcanic eruption centers (Hasandağ Composite Volcano and Acıgöl Caldera). Trace element, and stable (C and O) and radiogenic (Sr) isotope compositions of carbonate veins indicate different fluid migration pathways for two different fracture systems. The U/Th age data for carbonate veins of two independent fracture systems indicate that the crustal deformation intensified during 7 episodic periods in the last 150 ka. The NNE-trending first fracture system was formed as a result of strain cycles in a period from 149 ± 2.5, through 91 ± 1.5 to 83 ± 2.5 ka BP. Subsequent deformation events represented by the ENE-trending second fracture zone have been triggered during the period of 53 ± 3.5, 44 ± 0.6 and 34 ± 1 ka BP before the first fracture zone resumed the activity at about 4.7 ± 0.15 ka BP. Although further studies are needed to evaluate statistical significance of age correlations, the periods of carbonate precipitation inferred from U-Th age distributions in this study are comparable with the previous dating results of surrounding volcanic eruption events.

  11. Evaluating technology service options.

    PubMed

    Blumberg, D F

    1997-05-01

    Four service and support options are available to healthcare organizations for maintaining their growth arsenals of medical and information technology. These options include maintaining and servicing all equipment using a facility-based biomedical engineering and MIS service department; using a combination of facility-based service and subcontracted service; expanding facility-based biomedical and MIS service departments to provide service to other healthcare organizations to achieve economies of scale; and outsourcing all maintenance, repair, and technical support services. Independent service companies and original equipment manufacturers (OEMs) are offering healthcare organizations a wider array of service and support capabilities than ever before. However, some health systems have successfully developed their own independent service organizations to take care of their own--and other healthcare organizations'--service and support needs.

  12. Methodology evaluation: Effects of independent verification and intergration on one class of application

    NASA Technical Reports Server (NTRS)

    Page, J.

    1981-01-01

    The effects of an independent verification and integration (V and I) methodology on one class of application are described. Resource profiles are discussed. The development environment is reviewed. Seven measures are presented to test the hypothesis that V and I improve the development and product. The V and I methodology provided: (1) a decrease in requirements ambiguities and misinterpretation; (2) no decrease in design errors; (3) no decrease in the cost of correcting errors; (4) a decrease in the cost of system and acceptance testing; (5) an increase in early discovery of errors; (6) no improvement in the quality of software put into operation; and (7) a decrease in productivity and an increase in cost.

  13. Statistical evaluation of forecasts

    NASA Astrophysics Data System (ADS)

    Mader, Malenka; Mader, Wolfgang; Gluckman, Bruce J.; Timmer, Jens; Schelter, Björn

    2014-08-01

    Reliable forecasts of extreme but rare events, such as earthquakes, financial crashes, and epileptic seizures, would render interventions and precautions possible. Therefore, forecasting methods have been developed which intend to raise an alarm if an extreme event is about to occur. In order to statistically validate the performance of a prediction system, it must be compared to the performance of a random predictor, which raises alarms independent of the events. Such a random predictor can be obtained by bootstrapping or analytically. We propose an analytic statistical framework which, in contrast to conventional methods, allows for validating independently the sensitivity and specificity of a forecasting method. Moreover, our method accounts for the periods during which an event has to remain absent or occur after a respective forecast.

  14. Analysis and evaluation of the applicability of green energy technology

    NASA Astrophysics Data System (ADS)

    Xu, Z. J.; Song, Y. K.

    2017-11-01

    With the seriousness of environmental issues and the shortage of resources, the applicability of green energy technology has been paid more and more attention by scholars in different fields. However, the current researches are often single in perspective and simple in method. According to the Theory of Applicable Technology, this paper analyzes and defines the green energy technology and its applicability from the all-around perspectives of symbiosis of economy, society, environment and science & technology etc., and correspondingly constructs the evaluation index system. The paper further applies the Fuzzy Comprehensive Evaluation to the evaluation of its applicability, discusses in depth the evaluation models and methods, and explains in detail with an example. The author holds that the applicability of green energy technology involves many aspects of economy, society, environment and science & technology and can be evaluated comprehensively by an index system composed of a number of independent indexes. The evaluation is multi-object, multi-factor, multi-level and fuzzy comprehensive, which is undoubtedly correct, effective and feasible by the Fuzzy Comprehensive Evaluation. It is of vital theoretical and practical significance to understand and evaluate comprehensively the applicability of green energy technology for the rational development and utilization of green energy technology and for the better promotion of sustainable development of human and nature.

  15. 14 CFR 125.179 - Fuel system independence.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Fuel system independence. 125.179 Section... Requirements § 125.179 Fuel system independence. (a) Each airplane fuel system must be arranged so that the.... (b) A separate fuel tank need not be provided for each engine if the certificate holder shows that...

  16. TASLIMAGE System #2 Technical Equivalence Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Topper, J. D.; Stone, D. K.

    In early 2017, a second TASLIMAGE system (TASL 2) was procured from Track Analysis Systems, Ltd. The new device is intended to complement the first system (TASL 1) and to provide redundancy to the original system which was acquired in 2009. The new system functions primarily the same as the earlier system, though with different X-Y stage hardware and a USB link from the camera to the host computer, both of which contribute to a reduction in CR-39 foil imaging time. The camera and image analysis software are identical between the two systems. Neutron dose calculations are performed externally andmore » independent of the imaging system used to collect track data, relying only on the measured recoil proton track density per cm 2 for a set of known-dose CR-39 foils processed in each etch.« less

  17. Implementation of the IHR Joint External Evaluation: Taiwan's Experiences.

    PubMed

    Lo, Yi-Chun

    In February 2016, the World Health Organization developed the Joint External Evaluation (JEE) tool to independently assess country capacity to prevent, detect, and respond to public health threats as part of the International Health Regulations (IHR) (2005) monitoring and evaluation framework. In light of this, the Taiwan government actively engaged at least 19 government agencies or institutions and voluntarily implemented the JEE. An External Assessment Team consisting of 6 US subject matter experts conducted the external evaluation, including site visits, from June 21 to July 1, 2016. The results, published on October 18, 2016, are useful and will be translated into actions and change in the system. Based on Taiwan's experiences, early stakeholder engagement and an experts' pre-JEE pilot visit would contribute to a successful JEE process.

  18. 78 FR 13334 - Combined Notice of Filings #1

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-27

    .... Docket Numbers: ER13-940-000. Applicants: Midwest Independent Transmission System Operator, Inc. Description: Midwest Independent Transmission System Operator, Inc. submits Notice of Termination of Generator....m. ET 3/8/13. Docket Numbers: ER13-945-000. Applicants: Midwest Independent Transmission System...

  19. Design and Development of a Sharable Clinical Decision Support System Based on a Semantic Web Service Framework.

    PubMed

    Zhang, Yi-Fan; Gou, Ling; Tian, Yu; Li, Tian-Chang; Zhang, Mao; Li, Jing-Song

    2016-05-01

    Clinical decision support (CDS) systems provide clinicians and other health care stakeholders with patient-specific assessments or recommendations to aid in the clinical decision-making process. Despite their demonstrated potential for improving health care quality, the widespread availability of CDS systems has been limited mainly by the difficulty and cost of sharing CDS knowledge among heterogeneous healthcare information systems. The purpose of this study was to design and develop a sharable clinical decision support (S-CDS) system that meets this challenge. The fundamental knowledge base consists of independent and reusable knowledge modules (KMs) to meet core CDS needs, wherein each KM is semantically well defined based on the standard information model, terminologies, and representation formalisms. A semantic web service framework was developed to identify, access, and leverage these KMs across diverse CDS applications and care settings. The S-CDS system has been validated in two distinct client CDS applications. Model-level evaluation results confirmed coherent knowledge representation. Application-level evaluation results reached an overall accuracy of 98.66 % and a completeness of 96.98 %. The evaluation results demonstrated the technical feasibility and application prospect of our approach. Compared with other CDS engineering efforts, our approach facilitates system development and implementation and improves system maintainability, scalability and efficiency, which contribute to the widespread adoption of effective CDS within the healthcare domain.

  20. Computer-aided detection (CAD) of breast cancer on full field digital and screening film mammograms

    NASA Astrophysics Data System (ADS)

    Sun, Xuejun; Qian, Wei; Song, Xiaoshan; Qian, Yuyan; Song, Dansheng; Clark, Robert A.

    2003-05-01

    Full-field digital mammography (FFDM) as a new breast imaging modality has potential to detect more breast cancers or to detect them at smaller sizes and earlier stages compared with screening film mammography (SFM). However, its performance needs verification, and it would pose new problems for the development of CAD methods for breast cancer detection and diagnosis. Performance evaluation of CAD systems on FFDM and SFM has been conducted in this study, respectively. First, an adaptive CAD system employing a series of advanced modules has been developed on FFDM. Second, a standardization approach has been developed to make the CAD system independent of characteristics of digitizer or imaging modalities for mammography. CAD systems developed previously for SFM and developed in this study for FFDM have been evaluated on FFDM and SFM images without and with standardization, respectively, to examine the performance improvement of the CAD system developed in this study. Computerized free-response receiver operating characteristic (FROC) analysis has been adopted as performance evaluation method. Compared with previous one, the CAD system developed in this study demonstrated significantly performance improvements. However, the comparison results have shown that the performances of final CAD system in this study are not significantly different on FFDM and on SFM after standardization. It needs further study on the assessment of CAD system performance on FFDM and SFM modalities.

  1. Is a specific oncological scoring system better at predicting the prognosis of cancer patients admitted for an acute medical complication in an intensive care unit than general gravity scores?

    PubMed

    Berghmans, T; Paesmans, M; Sculier, J P

    2004-04-01

    To evaluate the effectiveness of a specific oncologic scoring system-the ICU Cancer Mortality model (ICM)-in predicting hospital mortality in comparison to two general severity scores-the Acute Physiology and Chronic Health Evaluation (APACHE II) and the Simplified Acute Physiology Score (SAPS II). All 247 patients admitted for a medical acute complication over an 18-month period in an oncological medical intensive care unit were prospectively registered. Their data, including type of complication, vital status at discharge and cancer characteristics as well as other variables necessary to calculate the three scoring systems were retrospectively assessed. Observed in-hospital mortality was 34%. The predicted in-hospital mortality rate for APACHE II was 32%; SAPS II, 24%; and ICM, 28%. The goodness of fit was inadequate except for the ICM score. Comparison of the area under the ROC curves revealed a better fit for ICM (area 0.79). The maximum correct classification rate was 72% for APACHE II, 74% for SAPS II and 77% for ICM. APACHE II and SAPS II were better at predicting outcome for survivors to hospital discharge, although ICM was better for non-survivors. Two variables were independently predicting the risk of death during hospitalisation: ICM (OR=2.31) and SAPS II (OR=1.05). Gravity scores were the single independent predictors for hospital mortality, and ICM was equivalent to APACHE II and SAPS II.

  2. Development of an Adaptable Display and Diagnostic System for the Evaluation of Tropical Cyclone Forecasts

    NASA Astrophysics Data System (ADS)

    Kucera, P. A.; Burek, T.; Halley-Gotway, J.

    2015-12-01

    NCAR's Joint Numerical Testbed Program (JNTP) focuses on the evaluation of experimental forecasts of tropical cyclones (TCs) with the goal of developing new research tools and diagnostic evaluation methods that can be transitioned to operations. Recent activities include the development of new TC forecast verification methods and the development of an adaptable TC display and diagnostic system. The next generation display and diagnostic system is being developed to support evaluation needs of the U.S. National Hurricane Center (NHC) and broader TC research community. The new hurricane display and diagnostic capabilities allow forecasters and research scientists to more deeply examine the performance of operational and experimental models. The system is built upon modern and flexible technology that includes OpenLayers Mapping tools that are platform independent. The forecast track and intensity along with associated observed track information are stored in an efficient MySQL database. The system provides easy-to-use interactive display system, and provides diagnostic tools to examine forecast track stratified by intensity. Consensus forecasts can be computed and displayed interactively. The system is designed to display information for both real-time and for historical TC cyclones. The display configurations are easily adaptable to meet the needs of the end-user preferences. Ongoing enhancements include improving capabilities for stratification and evaluation of historical best tracks, development and implementation of additional methods to stratify and compute consensus hurricane track and intensity forecasts, and improved graphical display tools. The display is also being enhanced to incorporate gridded forecast, satellite, and sea surface temperature fields. The presentation will provide an overview of the display and diagnostic system development and demonstration of the current capabilities.

  3. Effect of attitudes and perceptions of independent community pharmacy owners/managers on the comprehensiveness of strategic planning.

    PubMed

    Harrison, Donald L

    2006-01-01

    To assess the attitudes and perceptions of independent community pharmacy owners/managers about the comprehensiveness of strategic planning conducted for their pharmacies. Cross-sectional study. United States. Nationwide random sample of 1,250 owners/managers of independent community pharmacies. Mailed survey. Comprehensiveness of strategic planning conducted; components used in the strategic planning process. Attitudes and perceptions of owners/managers of independent community pharmacies toward strategic planning. A total of 527 (42.1%) usable questionnaires were returned. Of the 141 (26.8%) respondents who indicated that they conduct strategic planning, most components of the process were used. However, only 78 (55.3%) of those respondents conducted a review of pharmacy systems, and only 60 (42.6%) periodically evaluated implemented strategies. Approximately 88% of the variance in comprehensiveness was accounted for by 12 variables identified as significantly associated with the comprehensiveness of strategic planning conducted by owners/managers of independent community pharmacies. These included factors such as favorable cost-benefit relationship, impact of the Medicare Modernization Act of 2003, and remaining competitive in the pharmacy marketplace. While a minority of the survey population, respondents who reported conducting strategic planning used a reasonably comprehensive process. Further, several variables were identified as significant factors associated with comprehensiveness of strategic planning conducted.

  4. 28 CFR 700.31 - Exemption of the Office of Independent Counsel's systems of records-limited access.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Exemption of the Office of Independent Counsel's systems of records-limited access. 700.31 Section 700.31 Judicial Administration OFFICE OF INDEPENDENT COUNSEL PRODUCTION OR DISCLOSURE OF MATERIAL OR INFORMATION OF THE OFFICE OF INDEPENDENT COUNSEL Exemption of the Office of Independent...

  5. The prognostic value of reactive stroma on prostate needle biopsy: a population-based study.

    PubMed

    Saeter, Thorstein; Vlatkovic, Ljiljana; Waaler, Gudmund; Servoll, Einar; Nesland, Jahn M; Axcrona, Karol; Axcrona, Ulrika

    2015-05-01

    Reactive tumor stroma has been shown to play an active role in prostatic carcinogenesis. A grading system for reactive stroma in prostate cancer (PC) has recently been established and found to predict biochemical recurrence and prostate cancer-specific mortality (PCSM) in prostatectomized patients. To the best of our knowledge, there has been no study investigating the prognostic value of reactive stromal grading (RSG) with regard to PCSM when evaluated in diagnostic prostate needle biopsies. A population-based study on 318 patients, encompassing all cases of PC diagnosed by needle biopsies and without evidence of systemic metastasis at the time of diagnosis in Aust-Agder County in the period 1991-1999. Patients were identified by cross-referencing the Cancer Registry of Norway. Clinical data were obtained by review of medical charts. The endpoint was PCSM. RSG was evaluated on haematoxylin and eosin stained sections according to previously described criteria; grade 0, 0-5% reactive stroma; grade 1, 6-15%; grade 2, 16-50%; grade 3, 51-100%. RSG could be evaluated in 278 patients. The median follow- up time was 110 months (interquartile range: 51-171). The 10-year PC - specific survival rate for RSGs of 0, 1, 2, and 3 was 96%, 81%, 69%, and 63%, respectively (P < 0.005). RSG remained independently associated with PCSM in a multivariate Cox regression analysis adjusting for prostate-specific antigen level, clinical stage, Gleason score, and mode of treatment. The concordance index of the multivariate model was 0.814 CONCLUSIONS: Our study demonstrates that RSG in diagnostic prostate needle biopsies predicts PCSM independently of other evaluable prognostic factors. Hence, RSG could be used in addition to traditional prognostic factors for prognostication and treatment stratification of PC patients. © 2015 Wiley Periodicals, Inc.

  6. 78 FR 77447 - California Wind Energy Association, First Solar, Inc. v. California Independent System Operator...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-23

    ... Energy Association, First Solar, Inc. v. California Independent System Operator Corporation, Southern...), California Wind Energy Association and First Solar, Inc. (collectively, Complainants) filed a formal complaint against the California Independent System Operator Corporation (CAISO) and Southern California...

  7. 78 FR 9683 - Combined Notice of Filings #2

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-11

    .... Applicants: Midwest Independent Transmission System Operator, Inc. Description: 02-01-13 Errata filing Att O... p.m. ET 2/25/13. Docket Numbers: ER13-692-001. Applicants: Midwest Independent Transmission System... Mohawk Power Corporation, New York Independent System Operator, Inc. Description: Correction to...

  8. Doxycycline-Regulated 3T3-L1 Preadipocyte Cell Line with Inducible, Stable Expression of Adenoviral E4orf1 Gene: A Cell Model to Study Insulin-Independent Glucose Disposal

    PubMed Central

    Krishnapuram, Rashmi; Dhurandhar, Emily J.; Dubuisson, Olga; Hegde, Vijay; Dhurandhar, Nikhil V.

    2013-01-01

    Impaired glycemic control and excessive adiposity are major risk factors for Type 2 Diabetes mellitus. In rodent models, Ad36, a human adenovirus, improves glycemic control, independent of dietary fat intake or adiposity. It is impractical to use Ad36 for therapeutic action. Instead, we identified that E4orf1 protein of Ad36, mediates its anti-hyperglycemic action independent of insulin signaling. To further evaluate the therapeutic potential of E4orf1 to improve glycemic control, we established a stable 3T3-L1 cell system in which E4orf1 expression can be regulated. The development and characterization of this cell line is described here. Full-length adenoviral-36 E4orf1 cDNA obtained by PCR was cloned into a tetracycline responsive element containing vector (pTRE-Tight-E4orf1). Upon screening dozens of pTRE-Tight-E4orf1 clones, we identified the one with the highest expression of E4orf1 in response to doxycycline treatment. Furthermore, using this inducible system we characterized the ability of E4orf1 to improve glucose disposal in a time dependent manner. This stable cell line offers a valuable resource to carefully study the novel signaling pathways E4orf1 uses to enhance cellular glucose disposal independent of insulin. PMID:23544159

  9. Doxycycline-regulated 3T3-L1 preadipocyte cell line with inducible, stable expression of adenoviral E4orf1 gene: a cell model to study insulin-independent glucose disposal.

    PubMed

    Krishnapuram, Rashmi; Dhurandhar, Emily J; Dubuisson, Olga; Hegde, Vijay; Dhurandhar, Nikhil V

    2013-01-01

    Impaired glycemic control and excessive adiposity are major risk factors for Type 2 Diabetes mellitus. In rodent models, Ad36, a human adenovirus, improves glycemic control, independent of dietary fat intake or adiposity. It is impractical to use Ad36 for therapeutic action. Instead, we identified that E4orf1 protein of Ad36, mediates its anti-hyperglycemic action independent of insulin signaling. To further evaluate the therapeutic potential of E4orf1 to improve glycemic control, we established a stable 3T3-L1 cell system in which E4orf1 expression can be regulated. The development and characterization of this cell line is described here. Full-length adenoviral-36 E4orf1 cDNA obtained by PCR was cloned into a tetracycline responsive element containing vector (pTRE-Tight-E4orf1). Upon screening dozens of pTRE-Tight-E4orf1 clones, we identified the one with the highest expression of E4orf1 in response to doxycycline treatment. Furthermore, using this inducible system we characterized the ability of E4orf1 to improve glucose disposal in a time dependent manner. This stable cell line offers a valuable resource to carefully study the novel signaling pathways E4orf1 uses to enhance cellular glucose disposal independent of insulin.

  10. Evaluation of passenger health risk assessment of sustainable indoor air quality monitoring in metro systems based on a non-Gaussian dynamic sensor validation method.

    PubMed

    Kim, MinJeong; Liu, Hongbin; Kim, Jeong Tai; Yoo, ChangKyoo

    2014-08-15

    Sensor faults in metro systems provide incorrect information to indoor air quality (IAQ) ventilation systems, resulting in the miss-operation of ventilation systems and adverse effects on passenger health. In this study, a new sensor validation method is proposed to (1) detect, identify and repair sensor faults and (2) evaluate the influence of sensor reliability on passenger health risk. To address the dynamic non-Gaussianity problem of IAQ data, dynamic independent component analysis (DICA) is used. To detect and identify sensor faults, the DICA-based squared prediction error and sensor validity index are used, respectively. To restore the faults to normal measurements, a DICA-based iterative reconstruction algorithm is proposed. The comprehensive indoor air-quality index (CIAI) that evaluates the influence of the current IAQ on passenger health is then compared using the faulty and reconstructed IAQ data sets. Experimental results from a metro station showed that the DICA-based method can produce an improved IAQ level in the metro station and reduce passenger health risk since it more accurately validates sensor faults than do conventional methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Assessing performance of an Electronic Health Record (EHR) using Cognitive Task Analysis.

    PubMed

    Saitwal, Himali; Feng, Xuan; Walji, Muhammad; Patel, Vimla; Zhang, Jiajie

    2010-07-01

    Many Electronic Health Record (EHR) systems fail to provide user-friendly interfaces due to the lack of systematic consideration of human-centered computing issues. Such interfaces can be improved to provide easy to use, easy to learn, and error-resistant EHR systems to the users. To evaluate the usability of an EHR system and suggest areas of improvement in the user interface. The user interface of the AHLTA (Armed Forces Health Longitudinal Technology Application) was analyzed using the Cognitive Task Analysis (CTA) method called GOMS (Goals, Operators, Methods, and Selection rules) and an associated technique called KLM (Keystroke Level Model). The GOMS method was used to evaluate the AHLTA user interface by classifying each step of a given task into Mental (Internal) or Physical (External) operators. This analysis was performed by two analysts independently and the inter-rater reliability was computed to verify the reliability of the GOMS method. Further evaluation was performed using KLM to estimate the execution time required to perform the given task through application of its standard set of operators. The results are based on the analysis of 14 prototypical tasks performed by AHLTA users. The results show that on average a user needs to go through 106 steps to complete a task. To perform all 14 tasks, they would spend about 22 min (independent of system response time) for data entry, of which 11 min are spent on more effortful mental operators. The inter-rater reliability analysis performed for all 14 tasks was 0.8 (kappa), indicating good reliability of the method. This paper empirically reveals and identifies the following finding related to the performance of AHLTA: (1) large number of average total steps to complete common tasks, (2) high average execution time and (3) large percentage of mental operators. The user interface can be improved by reducing (a) the total number of steps and (b) the percentage of mental effort, required for the tasks. 2010 Elsevier Ireland Ltd. All rights reserved.

  12. Estimating the maximum potential revenue for grid connected electricity storage :

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Byrne, Raymond Harry; Silva Monroy, Cesar Augusto.

    2012-12-01

    The valuation of an electricity storage device is based on the expected future cash flow generated by the device. Two potential sources of income for an electricity storage system are energy arbitrage and participation in the frequency regulation market. Energy arbitrage refers to purchasing (stor- ing) energy when electricity prices are low, and selling (discharging) energy when electricity prices are high. Frequency regulation is an ancillary service geared towards maintaining system frequency, and is typically procured by the independent system operator in some type of market. This paper outlines the calculations required to estimate the maximum potential revenue from participatingmore » in these two activities. First, a mathematical model is presented for the state of charge as a function of the storage device parameters and the quantities of electricity purchased/sold as well as the quantities o ered into the regulation market. Using this mathematical model, we present a linear programming optimization approach to calculating the maximum potential revenue from an elec- tricity storage device. The calculation of the maximum potential revenue is critical in developing an upper bound on the value of storage, as a benchmark for evaluating potential trading strate- gies, and a tool for capital nance risk assessment. Then, we use historical California Independent System Operator (CAISO) data from 2010-2011 to evaluate the maximum potential revenue from the Tehachapi wind energy storage project, an American Recovery and Reinvestment Act of 2009 (ARRA) energy storage demonstration project. We investigate the maximum potential revenue from two di erent scenarios: arbitrage only and arbitrage combined with the regulation market. Our analysis shows that participation in the regulation market produces four times the revenue compared to arbitrage in the CAISO market using 2010 and 2011 data. Then we evaluate several trading strategies to illustrate how they compare to the maximum potential revenue benchmark. We conclude with a sensitivity analysis with respect to key parameters.« less

  13. Space Suit Portable Life Support System (PLSS) 2.0 Pre-Installation Acceptance (PIA) Testing

    NASA Technical Reports Server (NTRS)

    Anchondo, Ian; Cox, Marlon; Meginnis, Carly; Westheimer, David; Vogel, Matt R.

    2016-01-01

    Following successful completion of the space suit Portable Life Support System (PLSS) 1.0 development and testing in 2011, the second system-level prototype, PLSS 2.0, was developed in 2012 to continue the maturation of the advanced PLSS design. This advanced PLSS is intended to reduce consumables, improve reliability and robustness, and incorporate additional sensing and functional capabilities over the current Space Shuttle/International Space Station Extravehicular Mobility Unit (EMU) PLSS. PLSS 2.0 represents the first attempt at a packaged design comprising first generation or later component prototypes and medium fidelity interfaces within a flight-like representative volume. Pre-Installation Acceptance (PIA) is carryover terminology from the Space Shuttle Program referring to the series of test sequences used to verify functionality of the EMU PLSS prior to installation into the Space Shuttle airlock for launch. As applied to the PLSS 2.0 development and testing effort, PIA testing designated the series of 27 independent test sequences devised to verify component and subsystem functionality, perform in situ instrument calibrations, generate mapping data, define set-points, evaluate control algorithms, evaluate hardware performance against advanced PLSS design requirements, and provide quantitative and qualitative feedback on evolving design requirements and performance specifications. PLSS 2.0 PIA testing was carried out in 2013 and 2014 using a variety of test configurations to perform test sequences that ranged from stand-alone component testing to system-level testing, with evaluations becoming increasingly integrated as the test series progressed. Each of the 27 test sequences was vetted independently, with verification of basic functionality required before completion. Because PLSS 2.0 design requirements were evolving concurrently with PLSS 2.0 PIA testing, the requirements were used as guidelines to assess performance during the tests; after the completion of PIA testing, test data served to improve the fidelity and maturity of design requirements as well as plans for future advanced PLSS functional testing.

  14. 28 CFR 700.31 - Exemption of the Office of Independent Counsel's systems of records-limited access.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) (5) and (8); (f); and (g): (1) General Files System of the Office of Independent Counsel (OIC/001... Counsel's systems of records-limited access. 700.31 Section 700.31 Judicial Administration OFFICE OF... Exemption of the Office of Independent Counsel's Systems of Records Under the Privacy Act § 700.31 Exemption...

  15. 28 CFR 700.31 - Exemption of the Office of Independent Counsel's systems of records-limited access.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) (5) and (8); (f); and (g): (1) General Files System of the Office of Independent Counsel (OIC/001... Counsel's systems of records-limited access. 700.31 Section 700.31 Judicial Administration OFFICE OF... Exemption of the Office of Independent Counsel's Systems of Records Under the Privacy Act § 700.31 Exemption...

  16. 28 CFR 700.31 - Exemption of the Office of Independent Counsel's systems of records-limited access.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) (5) and (8); (f); and (g): (1) General Files System of the Office of Independent Counsel (OIC/001... Counsel's systems of records-limited access. 700.31 Section 700.31 Judicial Administration OFFICE OF... Exemption of the Office of Independent Counsel's Systems of Records Under the Privacy Act § 700.31 Exemption...

  17. 28 CFR 700.31 - Exemption of the Office of Independent Counsel's systems of records-limited access.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) (5) and (8); (f); and (g): (1) General Files System of the Office of Independent Counsel (OIC/001... Counsel's systems of records-limited access. 700.31 Section 700.31 Judicial Administration OFFICE OF... Exemption of the Office of Independent Counsel's Systems of Records Under the Privacy Act § 700.31 Exemption...

  18. Ubiquitin proteasome system in Parkinson's disease: a keeper or a witness?

    PubMed

    Martins-Branco, Diogo; Esteves, Ana R; Santos, Daniel; Arduino, Daniela M; Swerdlow, Russell H; Oliveira, Catarina R; Januario, Cristina; Cardoso, Sandra M

    2012-12-01

    The aim of this work was to evaluate the role of ubiquitin-proteasome system (UPS) on mitochondrial-driven alpha-synuclein (aSN) clearance in in vitro, ex vivo and in vivo Parkinson's disease (PD) cellular models. We used SH-SY5Y ndufa2 knock-down (KD) cells, PD cybrids and peripheral blood mononuclear cells (PBMC) from patients meeting the diagnostic criteria for PD. We quantified aSN aggregation, proteasome activity and protein ubiquitination levels. In PBMC of PD patient population we evaluated the aSN levels in the plasma and the influence of several demographic characteristics in the above mentioned determinations. We found that ubiquitin-independent proteasome activity was up-regulated in SH-SY5Y ndufa2 KD cells while a downregulation was observed in PD cybrids and PBMC. Moreover, we observed an increase in protein ubiquitination that correlates with a decrease in ubiquitin-dependent proteasome activity. Accordingly, proteasome inhibition prevented ubiquitin-dependent aSN clearance. Ubiquitin-independent proteasome activity was positively correlated with ubiquitination in PBMC. We also report a negative correlation of chymotrypsin-like activity with age in control and late-onset PD groups. Total ubiquitin content is positively correlated with aSN oligomer levels, which leads to an age-dependent increase of aSN ubiquitination in LOPD. Moreover, aSN levels are increased in the plasma of PD patients. aSN oligomers are ubiquitinated and we identified a ubiquitin-dependent clearance insufficiency with the accumulation of both aSN and ubiquitin. However, SH-SY5Y ndufa2 KD cells showed a significant up-regulation of ubiquitin-independent proteasomal enzymatic activity that could mean a cell rescue attempt. Moreover, we identified that UPS function is age-dependent in PBMC. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Should general practitioners purchase health care for their patients? The total purchasing experiment in Britain.

    PubMed

    Wyke, Sally; Mays, Nicholas; Street, Andrew; Bevan, Gwyn; McLeod, Hugh; Goodwin, Nick

    2003-09-01

    Until relatively recently, general practitioners (GPs) have been allowed to work independently, with no requirement to consider the resource implications of their referral and prescribing decisions. In order to align the interests of GPs with the overall objectives of health systems a number of countries have introduced primary care based capitation, funds pooling and budget holding either as experiments or as an overall policy. Are these experiments and policies likely to work? This paper presents evidence from the UK total purchasing experiment, which was the first major quasi-market development in the NHS to be independently evaluated from the outset. Total purchasing gave volunteer groups of practices freedom to purchase all hospital and community health services for their patients. The evidence suggests that whilst GPs have great potential as purchasers, they also have considerable limitations. The expectation that they will be able to improve the quality of patient experience of care, or to alter the use of resources, may not be generally realised. GP-based purchasing may be more appropriate where the task is to alter the balance or location of care between hospital and extramural settings. However, budgetary incentives are not 'magic potions' which have similar effects on behaviour wherever they are introduced. Holding budgets and having independent contracts, while important pre-requisites for being taken seriously in a quasi-market, were not sufficient for effective total purchasing. The paper concludes that health systems should not only value innovation and experimentation and encourage learning from evaluative research; they should also recognise the importance of supportive circumstances for any innovation to effect real and sustained change.

  20. Ubiquitin Proteasome System in Parkinson Disease: a keeper or a witness?

    PubMed Central

    Martins-Branco, Diogo; Esteves, Ana R.; Santos, Daniel; Arduino, Daniela M.; Swerdlow, Russell H.; Oliveira, Catarina R.; Januario, Cristina; Cardoso, Sandra M.

    2014-01-01

    Objective The aim of this work was to evaluate the role of Ubiquitin-Proteasome System (UPS) on mitochondrial-driven alpha-synuclein (aSN) clearance in in vitro, ex vivo and in vivo Parkinson disease (PD) cellular models. Method We used SH-SY5Y ndufa2 knock-down (KD) cells, PD cybrids and peripheral blood mononuclear cells (PBMC) from patients meeting the diagnostic criteria for PD. We quantified aSN aggregation, proteasome activity and protein ubiquitination levels. In PBMC of PD patients population we evaluated aSN levels in plasma and the influence of several demographic characteristics in the above mentioned determinations. Results We found that ubiquitin-independent proteasome activity was up-regulated in SH-SY5Y ndufa2 KD cells while a down regulation was observed in PD cybrids and PBMC. Moreover, we observed an increase in protein ubiquitination that correlates with a decrease in ubiquitin-dependent proteasome activity. Accordingly, proteasome inhibition prevented ubiquitin-dependent aSN clearance. Ubiquitin-independent proteasome activity was positively correlated with ubiquitination in PBMC. We also report a negative correlation of chymotrypsin-like activity with age in control and late-onset PD groups. Total ubiquitin content is positively correlated with aSN oligomers levels, which leads to an age-dependent increase of aSN ubiquitination in LOPD. Moreover, aSN levels are increased in the plasma of PD patients. Interpretation aSN oligomers are ubiquitinated and we identified an ubiquitin-dependent clearance insufficiency with accumulation of both aSN and ubiquitin. However, SH-SY5Y ndufa2 KD cells showed a significant up-regulation of ubiquitin-independent proteasomal enzymatic activity that could mean a cell rescue attempt. Moreover, we identified that UPS function is age-dependent in PBMC. PMID:22921536

  1. CUMBIN - CUMULATIVE BINOMIAL PROGRAMS

    NASA Technical Reports Server (NTRS)

    Bowerman, P. N.

    1994-01-01

    The cumulative binomial program, CUMBIN, is one of a set of three programs which calculate cumulative binomial probability distributions for arbitrary inputs. The three programs, CUMBIN, NEWTONP (NPO-17556), and CROSSER (NPO-17557), can be used independently of one another. CUMBIN can be used by statisticians and users of statistical procedures, test planners, designers, and numerical analysts. The program has been used for reliability/availability calculations. CUMBIN calculates the probability that a system of n components has at least k operating if the probability that any one operating is p and the components are independent. Equivalently, this is the reliability of a k-out-of-n system having independent components with common reliability p. CUMBIN can evaluate the incomplete beta distribution for two positive integer arguments. CUMBIN can also evaluate the cumulative F distribution and the negative binomial distribution, and can determine the sample size in a test design. CUMBIN is designed to work well with all integer values 0 < k <= n. To run the program, the user simply runs the executable version and inputs the information requested by the program. The program is not designed to weed out incorrect inputs, so the user must take care to make sure the inputs are correct. Once all input has been entered, the program calculates and lists the result. The CUMBIN program is written in C. It was developed on an IBM AT with a numeric co-processor using Microsoft C 5.0. Because the source code is written using standard C structures and functions, it should compile correctly with most C compilers. The program format is interactive. It has been implemented under DOS 3.2 and has a memory requirement of 26K. CUMBIN was developed in 1988.

  2. An Independent Evaluation of the Switching Operations Facility Analysis 2010 Working Group's Processes

    DOT National Transportation Integrated Search

    2009-12-01

    The Switching Operations Fatality Analysis (SOFA) Working Group was formed to analyze the factors contributing to fatalities in switching operations. The 2010 Working Group invited an independent team of evaluators to assess the thoroughness of the S...

  3. The Romhilt-Estes electrocardiographic score predicts sudden cardiac arrest independent of left ventricular mass and ejection fraction.

    PubMed

    Darouian, Navid; Aro, Aapo L; Narayanan, Kumar; Uy-Evanado, Audrey; Rusinaru, Carmen; Reinier, Kyndaron; Gunson, Karen; Jui, Jonathan; Chugh, Sumeet S

    2017-07-01

    The Romhilt-Estes point score system (RE) is an established ECG criterion for diagnosing left ventricular hypertrophy (LVH). In this study, we assessed for the first time, whether RE and its components are predictive of sudden cardiac arrest (SCA) independent of left ventricular (LV) mass. Sudden cardiac arrest (SCA) cases occurring between 2002 and 2014 in a Northwestern US metro region (catchment area approx. 1 million) were compared to geographic controls. ECGs and echocardiograms performed prior to the SCA and those of controls were acquired from the medical records and evaluated for the ECG criteria established in the RE score and for LV mass. Two hundred forty-seven SCA cases (age 68.3 ± 14.6, male 64.4%) and 330 controls (age 67.4 ± 11.5, male 63.6) were included in the analysis. RE scores were greater in cases than controls (2.5 ± 2.1 vs. 1.9 ± 1.7, p < .001), and SCA cases were more likely to meet definite LVH criteria (18.6% vs. 7.9%, p < .001). In a multivariable model including echocardiographic LVH and LV function, definite LVH remained independently predictive of SCA (OR 2.04, 95% CI 1.16-3.59, p = .013). The model was replicated with the individual ECG criteria, and only SV 1.2  ≥ 30 mm and delayed intrinsicoid deflection remained significant predictors of SCA. Left ventricular hypertrophy (LVH) as defined by the RE point score system is associated with SCA independent of echocardiographic LVH and reduced LV ejection fraction. These findings support an independent role for purely electrical LVH, in the genesis of lethal ventricular arrhythmias. © 2017 Wiley Periodicals, Inc.

  4. [Development and evaluation of the medical imaging distribution system with dynamic web application and clustering technology].

    PubMed

    Yokohama, Noriya; Tsuchimoto, Tadashi; Oishi, Masamichi; Itou, Katsuya

    2007-01-20

    It has been noted that the downtime of medical informatics systems is often long. Many systems encounter downtimes of hours or even days, which can have a critical effect on daily operations. Such systems remain especially weak in the areas of database and medical imaging data. The scheme design shows the three-layer architecture of the system: application, database, and storage layers. The application layer uses the DICOM protocol (Digital Imaging and Communication in Medicine) and HTTP (Hyper Text Transport Protocol) with AJAX (Asynchronous JavaScript+XML). The database is designed to decentralize in parallel using cluster technology. Consequently, restoration of the database can be done not only with ease but also with improved retrieval speed. In the storage layer, a network RAID (Redundant Array of Independent Disks) system, it is possible to construct exabyte-scale parallel file systems that exploit storage spread. Development and evaluation of the test-bed has been successful in medical information data backup and recovery in a network environment. This paper presents a schematic design of the new medical informatics system that can be accommodated from a recovery and the dynamic Web application for medical imaging distribution using AJAX.

  5. Self-perceptions and their Prediction of Aggression in Male Juvenile Offenders.

    PubMed

    Smith, Stephanie D; Lynch, Rebecca J; Stephens, Haley F; Kistner, Janet A

    2015-08-01

    This study evaluated multiple facets of self-perceptions that have been theorized and shown to play a contributory role in the development of aggression for less clinically severe populations in a sample of youths from the juvenile justice system. Independent and unique associations of low self-esteem and inflated self-perceptions with aggression were examined in a sample of male juvenile offenders (N = 119; Mean age = 16.74 years) using a longitudinal study design. Latent growth curve modeling analyses revealed that self-esteem, adaptive and maladaptive narcissism independently predicted juvenile offenders' initial levels of aggression. It was also found that perceptual bias independently predicted changes in aggression over time. With the inclusion of all variables in the same model, self-esteem was no longer associated with aggression; however, all other relationships remained significant. The implications of these findings as well as the importance of interventions targeting self-perceptions to decrease aggression among high-risk youths are discussed.

  6. 3D hierarchical interface-enriched finite element method: Implementation and applications

    NASA Astrophysics Data System (ADS)

    Soghrati, Soheil; Ahmadian, Hossein

    2015-10-01

    A hierarchical interface-enriched finite element method (HIFEM) is proposed for the mesh-independent treatment of 3D problems with intricate morphologies. The HIFEM implements a recursive algorithm for creating enrichment functions that capture gradient discontinuities in nonconforming finite elements cut by arbitrary number and configuration of materials interfaces. The method enables the mesh-independent simulation of multiphase problems with materials interfaces that are in close proximity or contact while providing a straightforward general approach for evaluating the enrichments. In this manuscript, we present a detailed discussion on the implementation issues and required computational geometry considerations associated with the HIFEM approximation of thermal and mechanical responses of 3D problems. A convergence study is provided to investigate the accuracy and convergence rate of the HIFEM and compare them with standard FEM benchmark solutions. We will also demonstrate the application of this mesh-independent method for simulating the thermal and mechanical responses of two composite materials systems with complex microstructures.

  7. An onboard navigation system which fulfills Mars aerocapture guidance requirements

    NASA Technical Reports Server (NTRS)

    Brand, Timothy J.; Fuhry, Douglas P.; Shepperd, Stanley W.

    1989-01-01

    The development of a candidate autonomous onboard Mars approach navigation scheme capable of supporting aerocapture into Mars orbit is discussed. An aerocapture guidance and navigation system which can run independently of the preaerocapture navigation was used to define a preliminary set of accuracy requirements at entry interface. These requirements are used to evaluate the proposed preaerocapture navigation scheme. This scheme uses optical sightings on Deimos with a star tracker and an inertial measurement unit for instrumentation as a source for navigation nformation. Preliminary results suggest that the approach will adequately support aerocaputre into Mars orbit.

  8. What can Europeans learn from Americans?

    PubMed Central

    Enthoven, Alain C.

    1989-01-01

    In a wide-ranging look at many aspects of health care financing and delivery, the concepts of glasnost and perestroika are used as a framework for presenting ideas from the American system that may have value for European health care planners. These include more uniform approaches to data collection and cost reporting, patient outcome studies, evaluation of service and access standards, publication of information, quality assurance review, decentralization and independent institutions, prepaid group practice, demonstrations and experiments, and managed competition. Suggestions are offered for making health care systems on both sides of the Atlantic more manageable, efficient, and responsive. PMID:10313435

  9. Joint Polar Satellite System (JPSS) Micrometeoroid and Orbital Debris (MMOD) Assessment

    NASA Technical Reports Server (NTRS)

    Squire, Michael D.; Cooke, William J.; Williamsen, Joel; Kessler, Donald; Vesely, William E.; Hull, Scott H.; Schonberg, William; Peterson, Glenn E.; Jenkin, Alan B.; Cornford, Steven L.

    2015-01-01

    The Joint Polar Satellite System (JPSS) Project requested the NASA Engineering and Safety Center (NESC) conduct an independent evaluation of the Micrometeoroid and Orbital Debris (MMOD) models used in the latest JPSS MMOD risk assessment. The principal focus of the assessment was to compare Orbital Debris Engineering Model version 3 (ORDEM 3.0) with the Meteoroid and Space Debris Terrestrial Environment Reference version 2009 (MASTER-2009) and Aerospace Debris Environment Projection Tool (ADEPT) and provide recommendations to the JPSS Project regarding MMOD protection. The outcome of the NESC assessment is contained in this report.

  10. Teaching children with autism to engage in peer-directed mands using a picture exchange communication system.

    PubMed

    Paden, Amber R; Kodak, Tiffany; Fisher, Wayne W; Gawley-Bullington, Elizabeth M; Bouxsein, Kelly J

    2012-01-01

    We evaluated differential reinforcement of alternative behavior (DRA) plus prompting to increase peer-directed mands for preferred items using a picture exchange communication system (PECS). Two nonvocal individuals with autism participated. Independent mands with a peer increased with the implementation of DRA plus prompting for both participants. In addition, peers engaged in brief social interactions following the majority of mands for leisure items. These results suggest that teaching children to use PECS with peers may be one way to increase manding and social interactions in individuals with limited or no vocal repertoire.

  11. TEACHING CHILDREN WITH AUTISM TO ENGAGE IN PEER-DIRECTED MANDS USING A PICTURE EXCHANGE COMMUNICATION SYSTEM

    PubMed Central

    Paden, Amber R; Kodak, Tiffany; Fisher, Wayne W; Gawley-Bullington, Elizabeth M; Bouxsein, Kelly J

    2012-01-01

    We evaluated differential reinforcement of alternative behavior (DRA) plus prompting to increase peer-directed mands for preferred items using a picture exchange communication system (PECS). Two nonvocal individuals with autism participated. Independent mands with a peer increased with the implementation of DRA plus prompting for both participants. In addition, peers engaged in brief social interactions following the majority of mands for leisure items. These results suggest that teaching children to use PECS with peers may be one way to increase manding and social interactions in individuals with limited or no vocal repertoire. PMID:22844150

  12. SIRU development. Volume 3: Software description and program documentation

    NASA Technical Reports Server (NTRS)

    Oehrle, J.

    1973-01-01

    The development and initial evaluation of a strapdown inertial reference unit (SIRU) system are discussed. The SIRU configuration is a modular inertial subsystem with hardware and software features that achieve fault tolerant operational capabilities. The SIRU redundant hardware design is formulated about a six gyro and six accelerometer instrument module package. The six axes array provides redundant independent sensing and the symmetry enables the formulation of an optimal software redundant data processing structure with self-contained fault detection and isolation (FDI) capabilities. The basic SIRU software coding system used in the DDP-516 computer is documented.

  13. Autonomous Relative Navigation for Formation-Flying Satellites Using GPS

    NASA Technical Reports Server (NTRS)

    Gramling, Cheryl; Carpenter, J. Russell; Long, Anne; Kelbel, David; Lee, Taesul

    2000-01-01

    The Goddard Space Flight Center is currently developing advanced spacecraft systems to provide autonomous navigation and control of formation flyers. This paper discusses autonomous relative navigation performance for a formation of four eccentric, medium-altitude Earth-orbiting satellites using Global Positioning System (GPS) Standard Positioning Service (SPS) and "GPS-like " intersatellite measurements. The performance of several candidate relative navigation approaches is evaluated. These analyses indicate that an autonomous relative navigation position accuracy of 1meter root-mean-square can be achieved by differencing high-accuracy filtered solutions if only measurements from common GPS space vehicles are used in the independently estimated solutions.

  14. 38 CFR 21.160 - Independent living services.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... furnished: (1) As part of a program to achieve rehabilitation to the point of employability; (2) As part of...) Evaluation of independent living potential; (ii) Training in independent living skills; (iii) Attendant care...

  15. Laparoscopic training using a quantitative assessment and instructional system.

    PubMed

    Yamaguchi, T; Nakamura, R

    2018-04-28

    Laparoscopic surgery requires complex surgical skills; hence, surgeons require regular training to improve their surgical techniques. The quantitative assessment of a surgeon's skills and the provision of feedback are important processes for conducting effective training. The aim of this study was to develop an inexpensive training system that provides automatic technique evaluation and feedback. We detected the instrument using image processing of commercial web camera images and calculated the motion analysis parameters (MAPs) of the instrument to quantify performance features. Upon receiving the results, we developed a method of evaluating the surgeon's skill level. The feedback system was developed using MAPs-based radar charts and scores for determining the skill level. These methods were evaluated using the videos of 38 surgeons performing a suturing task. There were significant differences in MAPs among surgeons; therefore, MAPs can be effectively used to quantify a surgeon's performance features. The results of skill evaluation and feedback differed greatly between skilled and unskilled surgeons, and it was possible to indicate points of improvement for the procedure performed in this study. Furthermore, the results obtained for certain novice surgeons were similar to those obtained for skilled surgeons. This system can be used to assess the skill level of surgeons, independent of the years of experience, and provide an understanding of the individual's current surgical skill level effectively. We conclude that our system is useful as an inexpensive laparoscopic training system that might aid in skill improvement.

  16. Quantitative evaluation of patient-specific quality assurance using online dosimetry system

    NASA Astrophysics Data System (ADS)

    Jung, Jae-Yong; Shin, Young-Ju; Sohn, Seung-Chang; Min, Jung-Whan; Kim, Yon-Lae; Kim, Dong-Su; Choe, Bo-Young; Suh, Tae-Suk

    2018-01-01

    In this study, we investigated the clinical performance of an online dosimetry system (Mobius FX system, MFX) by 1) dosimetric plan verification using gamma passing rates and dose volume metrics and 2) error-detection capability evaluation by deliberately introduced machine error. Eighteen volumetric modulated arc therapy (VMAT) plans were studied. To evaluate the clinical performance of the MFX, we used gamma analysis and dose volume histogram (DVH) analysis. In addition, to evaluate the error-detection capability, we used gamma analysis and DVH analysis utilizing three types of deliberately introduced errors (Type 1: gantry angle-independent multi-leaf collimator (MLC) error, Type 2: gantry angle-dependent MLC error, and Type 3: gantry angle error). A dosimetric verification comparison of physical dosimetry system (Delt4PT) and online dosimetry system (MFX), gamma passing rates of the two dosimetry systems showed very good agreement with treatment planning system (TPS) calculation. For the average dose difference between the TPS calculation and the MFX measurement, most of the dose metrics showed good agreement within a tolerance of 3%. For the error-detection comparison of Delta4PT and MFX, the gamma passing rates of the two dosimetry systems did not meet the 90% acceptance criterion with the magnitude of error exceeding 2 mm and 1.5 ◦, respectively, for error plans of Types 1, 2, and 3. For delivery with all error types, the average dose difference of PTV due to error magnitude showed good agreement between calculated TPS and measured MFX within 1%. Overall, the results of the online dosimetry system showed very good agreement with those of the physical dosimetry system. Our results suggest that a log file-based online dosimetry system is a very suitable verification tool for accurate and efficient clinical routines for patient-specific quality assurance (QA).

  17. Information Flow Integrity for Systems of Independently-Developed Components

    DTIC Science & Technology

    2015-06-22

    We also examined three programs (Apache, MySQL , and PHP) in detail to evaluate the efficacy of using the provided package test suites to generate...method are just as effective as hooks that were manually placed over the course of years while greatly reducing the burden on programmers. ”Leveraging...to validate optimizations of real-world, mature applications: the Apache software suite, the Mozilla Suite, and the MySQL database. ”Validating Library

  18. Statistical Measurement and Analysis of Claimant and Demographic Variables Affecting Processing and Adjudication Duration in The United States Army Physical Disability Evaluation System.

    DTIC Science & Technology

    1997-02-06

    Adjudication Duration 2 2. INTRODUCTION This retrospective study analyzes relationships of variables to adjudication and processing duration in the Army...Package for Social Scientists (SPSS), Standard Version 6.1, June 1994, to determine relationships among the dependent and independent variables... consanguinity between variables. Content and criterion validity is employed to determine the measure of scientific validity. Reliability is also

  19. Evolution of Occupant Survivability Simulation Framework Using FEM-SPH Coupling

    DTIC Science & Technology

    2011-08-01

    SPH Coupling, Dooge and Thyagarajan. UNCLASSIFIED: Dist A. Approved for public release Page 2 of 14 works outward in the chain: soldier  seats ...reduced degree of freedom (DOF) system, evaluation of occupant seating independent of the vehicle environment, or using a substructure approach to...the ejected material covering the charge imposes most of the loading onto the structure above. The properties of the material in the "soil cap" are

  20. Lower extremity robotic exoskeleton training: Case studies for complete spinal cord injury walking.

    PubMed

    Lemaire, Edward D; Smith, Andrew J; Herbert-Copley, Andrew; Sreenivasan, Vidya

    2017-01-01

    Recent advances in exoskeleton technology has made lower extremity powered exoskeletons (LEPE) a viable treatment tool to restore upright walking mobility to persons with spinal cord injury (SCI). Evaluate ARKE exoskeleton training within a rehabilitation centre environment. Case studies are presented for two male participants, age 41 and 30, motor complete SCI at T6 (N01) and T12 (N02), respectively, as they progress from new LEPE users to independent walking. The ARKE 2.0 LEPE (Bionik Laboratories Inc., Toronto, Canada) was used for all training (hip and knee powered, forearm crutches, control tablet). Data were collected on session times, activity metrics from ARKE system logs, and qualitative questionnaire feedback. N01 required 18, 30-minute training sessions to achieve independent walking. N01 walked independently within the 12 session target. Foot strikes were frequently before the end of the programmed swing phase, which were handled by the ARKE control system. Subjective ratings of LEPE learning, comfort, pain, fatigue, and overall experience were high for sitting-standing and moderate to high for walking. This reflected the complexity of learning to safely walk. Qualitative feedback supported the continuation of LEPE use in rehabilitation settings based on end-user desire for upright mobility.

  1. The 100 kW space station. [regenerative fuel cells and nickel hydrogen and nickel cadmium batteries for solar arrays

    NASA Technical Reports Server (NTRS)

    Mckhann, G.

    1977-01-01

    Solar array power systems for the space construction base are discussed. Nickel cadmium and nickel hydrogen batteries are equally attractive relative to regenerative fuel cell systems at 5 years life. Further evaluation of energy storage system life (low orbit conditions) is required. Shuttle and solid polymer electrolyte fuel cell technology appears adequate; large units (approximately four times shuttle) are most appropriate and should be studied for a 100 KWe SCB system. A conservative NiH2 battery DOD (18.6%) was elected due to lack of test data and offers considerable improvement potential. Multiorbit load averaging and reserve capacity requirements limit nominal DOD to 30% to 50% maximum, independent of life considerations.

  2. Garbage Collection in a Distributed Object-Oriented System

    NASA Technical Reports Server (NTRS)

    Gupta, Aloke; Fuchs, W. Kent

    1993-01-01

    An algorithm is described in this paper for garbage collection in distributed systems with object sharing across processor boundaries. The algorithm allows local garbage collection at each node in the system to proceed independently of local collection at the other nodes. It requires no global synchronization or knowledge of the global state of the system and exhibits the capability of graceful degradation. The concept of a specialized dump node is proposed to facilitate the collection of inaccessible circular structures. An experimental evaluation of the algorithm is also described. The algorithm is compared with a corresponding scheme that requires global synchronization. The results show that the algorithm works well in distributed processing environments even when the locality of object references is low.

  3. Ropes: Support for collective opertions among distributed threads

    NASA Technical Reports Server (NTRS)

    Haines, Matthew; Mehrotra, Piyush; Cronk, David

    1995-01-01

    Lightweight threads are becoming increasingly useful in supporting parallelism and asynchronous control structures in applications and language implementations. Recently, systems have been designed and implemented to support interprocessor communication between lightweight threads so that threads can be exploited in a distributed memory system. Their use, in this setting, has been largely restricted to supporting latency hiding techniques and functional parallelism within a single application. However, to execute data parallel codes independent of other threads in the system, collective operations and relative indexing among threads are required. This paper describes the design of ropes: a scoping mechanism for collective operations and relative indexing among threads. We present the design of ropes in the context of the Chant system, and provide performance results evaluating our initial design decisions.

  4. Reusing models of actors and services in smart homecare to improve sustainability.

    PubMed

    Walderhaug, Ståle; Stav, Erlend; Mikalsen, Marius

    2008-01-01

    Industrial countries are faced with a growing elderly population. Homecare systems with assistive smart house technology enable elderly to live independently at home. Development of such smart home care systems is complex and expensive and there is no common reference model that can facilitate service reuse. This paper proposes reusable actor and service models based on a model-driven development process where end user organizations and domain healthcare experts from four European countries have been involved. The models, specified using UML can be reused actively as assets in the system design and development process and can reduce development costs, and improve interoperability and sustainability of systems. The models are being evaluated in the European IST project MPOWER.

  5. Real-time automated failure analysis for on-orbit operations

    NASA Technical Reports Server (NTRS)

    Kirby, Sarah; Lauritsen, Janet; Pack, Ginger; Ha, Anhhoang; Jowers, Steven; Mcnenny, Robert; Truong, The; Dell, James

    1993-01-01

    A system which is to provide real-time failure analysis support to controllers at the NASA Johnson Space Center Control Center Complex (CCC) for both Space Station and Space Shuttle on-orbit operations is described. The system employs monitored systems' models of failure behavior and model evaluation algorithms which are domain-independent. These failure models are viewed as a stepping stone to more robust algorithms operating over models of intended function. The described system is designed to meet two sets of requirements. It must provide a useful failure analysis capability enhancement to the mission controller. It must satisfy CCC operational environment constraints such as cost, computer resource requirements, verification, and validation. The underlying technology and how it may be used to support operations is also discussed.

  6. Mobile system for in-situ imaging of cultural objects

    NASA Astrophysics Data System (ADS)

    Zemlicka, J.; Jakubek, J.; Krejci, F.; Hradil, D.; Hradilova, J.; Mislerova, H.

    2012-01-01

    Non-invasive analytical techniques recently developed with the Timepix pixel detector have shown great potential for the inspection of objects of cultural heritage. We have developed new instrumentation and methodology for in-situ X-ray transmission radiography and X-ray fluorescence imaging and successfully tested and evaluated a mobile system for remote terrain tasks. The prototype portable imaging device comprises the radiation source tube and the spectral sensitive X-ray camera. Both components can be moreover mounted on independent motorized positioning systems allowing adaptation of irradiation geometry to the object shape. Both parts are placed onto a pair of universal portable holders (tripods). The detector is placed in a shielded box with exchangeable entrance window (beam filters and pinhole collimator). This adjustable setup allows performing in-situ measurements for both transmission and emission (XRF) radiography. The assembled system has been successfully tested in our laboratory with phantoms and real samples. The obtained and evaluated results are presented in this paper. Future work will include successive adaptation of the current system for real in-situ utilization and preparation of software allowing semi-automatic remote control of measurements.

  7. Laser projection positioning of spatial contour curves via a galvanometric scanner

    NASA Astrophysics Data System (ADS)

    Tu, Junchao; Zhang, Liyan

    2018-04-01

    The technology of laser projection positioning is widely applied in advanced manufacturing fields (e.g. composite plying, parts location and installation). In order to use it better, a laser projection positioning (LPP) system is designed and implemented. Firstly, the LPP system is built by a laser galvanometric scanning (LGS) system and a binocular vision system. Applying Single-hidden Layer Feed-forward Neural Network (SLFN), the system model is constructed next. Secondly, the LGS system and the binocular system, which are respectively independent, are integrated through a datadriven calibration method based on extreme learning machine (ELM) algorithm. Finally, a projection positioning method is proposed within the framework of the calibrated SLFN system model. A well-designed experiment is conducted to verify the viability and effectiveness of the proposed system. In addition, the accuracy of projection positioning are evaluated to show that the LPP system can achieves the good localization effect.

  8. APNEA/WIT system nondestructive assay capability evaluation plan for select accessibly stored INEL RWMC waste forms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Becker, G.K.

    1997-01-01

    Bio-Imaging Research Inc. (BIR) and Lockheed Martin Speciality Components (LMSC) are engaged in a Program Research and Development Agreement and a Rapid Commercialization Initiative with the Department of Energy, EM-50. The agreement required BIR and LMSC to develop a data interpretation method that merges nondestructive assay and nondestructive examination (NDA/NDE) data and information sufficient to establish compliance with applicable National TRU Program (Program) waste characterization requirements and associated quality assurance performance criteria. This effort required an objective demonstration of the BIR and LMSC waste characterization systems in their standalone and integrated configurations. The goal of the test plan is tomore » provide a mechanism from which evidence can be derived to substantiate nondestructive assay capability and utility statement for the BIT and LMSC systems. The plan must provide for the acquisition, compilation, and reporting of performance data thereby allowing external independent agencies a basis for an objective evaluation of the standalone BIR and LMSC measurement systems, WIT and APNEA respectively, as well as an expected performance resulting from appropriate integration of the two systems. The evaluation is to be structured such that a statement regarding select INEL RWMC waste forms can be made in terms of compliance with applicable Program requirements and criteria.« less

  9. 76 FR 4104 - Notice of Commission Staff Attendance at Midwest ISO Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-24

    ... Transmission System Operator, Inc., et al. Docket No. ER05-1085, et al., Midwest Independent Transmission..., Midwest Independent Transmission System Operator, Inc. Docket No. ER10-1085, Midwest Independent...

  10. 75 FR 51996 - Notice of Commission Staff Attendance at Midwest ISO Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-24

    ... Transmission System Operator, Inc., et al. Docket No. ER05-1085, et al., Midwest Independent Transmission..., Midwest Independent Transmission System Operator, Inc. Docket No. ER10-1085, Midwest Independent...

  11. 30 CFR 6.10 - Use of independent laboratories.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Use of independent laboratories. 6.10 Section 6..., AND APPROVAL OF MINING PRODUCTS TESTING AND EVALUATION BY INDEPENDENT LABORATORIES AND NON-MSHA PRODUCT SAFETY STANDARDS § 6.10 Use of independent laboratories. (a) MSHA will accept testing and...

  12. A Randomized, Controlled Trial of Intranasal Oxytocin as an Adjunct to Behavioral Therapy for Autism Spectrum Disorder

    DTIC Science & Technology

    2015-10-01

    Fellowship of the Alexander von Humboldt Foundation , MIT Name: Dina Hirshfeld- Becker , PhD Project Role: Independent Evaluator Researcher Identifier...e.g. ORCID ID): Nearest person month worked: 3 Contribution to Project: Dr. Hirshfeld- Becker has been an independent evaluator and has evaluated ...either intranasal oxytocin or placebo. Participants and evaluators will be blind to treatment condition. In year 1 of the study, we set up the study

  13. Evaluating the Feasibility of RESCUE: An Adjunctive HAI-Based Intervention for Veterans with PTSD

    DTIC Science & Technology

    2017-05-01

    with clinicians on study 9/14/16 – 9/16/16. c) Independent evaluators completed 1-day Clinician Administered PTSD Scale (CAPS) training 10/31/16. d...therapists Recruit, facilitate hiring, and train study independent evaluators (IEs) 0-6 100% Facilitate and coordinate training and PE certification...developed referral stream for study 6 - 8 100% Major Task 3: Conduct pre-treatment evaluations for case series Screen, obtain consent, assess, and

  14. Online performance evaluation of RAID 5 using CPU utilization

    NASA Astrophysics Data System (ADS)

    Jin, Hai; Yang, Hua; Zhang, Jiangling

    1998-09-01

    Redundant arrays of independent disks (RAID) technology is the efficient way to solve the bottleneck problem between CPU processing ability and I/O subsystem. For the system point of view, the most important metric of on line performance is the utilization of CPU. This paper first employs the way to calculate the CPU utilization of system connected with RAID level 5 using statistic average method. From the simulation results of CPU utilization of system connected with RAID level 5 subsystem can we see that using multiple disks as an array to access data in parallel is the efficient way to enhance the on-line performance of disk storage system. USing high-end disk drivers to compose the disk array is the key to enhance the on-line performance of system.

  15. Tracking Data Acquisition System (TDAS) for the 1990's. Volume 6: TDAS navigation system architecture

    NASA Technical Reports Server (NTRS)

    Elrod, B. D.; Jacobsen, A.; Cook, R. A.; Singh, R. N. P.

    1983-01-01

    One-way range and Doppler methods for providing user orbit and time determination are examined. Forward link beacon tracking, with on-board processing of independent navigation signals broadcast continuously by TDAS spacecraft; forward link scheduled tracking; with on-board processing of navigation data received during scheduled TDAS forward link service intervals; and return link scheduled tracking; with ground-based processing of user generated navigation data during scheduled TDAS return link service intervals are discussed. A system level definition and requirements assessment for each alternative, an evaluation of potential navigation performance and comparison with TDAS mission model requirements is included. TDAS satellite tracking is also addressed for two alternatives: BRTS and VLBI tracking.

  16. Intelligent Text Retrieval and Knowledge Acquisition from Texts for NASA Applications: Preprocessing Issues

    NASA Technical Reports Server (NTRS)

    2002-01-01

    A system that retrieves problem reports from a NASA database is described. The database is queried with natural language questions. Part-of-speech tags are first assigned to each word in the question using a rule based tagger. A partial parse of the question is then produced with independent sets of deterministic finite state a utomata. Using partial parse information, a look up strategy searches the database for problem reports relevant to the question. A bigram stemmer and irregular verb conjugates have been incorporated into the system to improve accuracy. The system is evaluated by a set of fifty five questions posed by NASA engineers. A discussion of future research is also presented.

  17. Schlieren Technique Applied to Magnetohydrodynamic Generator Plasma Torch

    NASA Astrophysics Data System (ADS)

    Chopra, Nirbhav; Pearcy, Jacob; Jaworski, Michael

    2017-10-01

    Magnetohydrodynamic (MHD) generators are a promising augmentation to current hydrocarbon based combustion schemes for creating electrical power. In recent years, interest in MHD generators has been revitalized due to advances in a number of technologies such as superconducting magnets, solid-state power electronics and materials science as well as changing economics associated with carbon capture, utilization, and sequestration. We use a multi-wavelength schlieren imaging system to evaluate electron density independently of gas density in a plasma torch under conditions relevant to MHD generators. The sensitivity and resolution of the optical system are evaluated alongside the development of an automated analysis and calibration program in Python. Preliminary analysis shows spatial resolutions less than 1mm and measures an electron density of ne = 1 ×1016 cm-3 in an atmospheric microwave torch. Work supported by DOE contract DE-AC02-09CH11466.

  18. Independent Orbiter Assessment (IOA): Analysis of the electrical power distribution and control/electrical power generation subsystem

    NASA Technical Reports Server (NTRS)

    Patton, Jeff A.

    1986-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Electrical Power Distribution and Control (EPD and C)/Electrical Power Generation (EPG) hardware. The EPD and C/EPG hardware is required for performing critical functions of cryogenic reactant storage, electrical power generation and product water distribution in the Orbiter. Specifically, the EPD and C/EPG hardware consists of the following components: Power Section Assembly (PSA); Reactant Control Subsystem (RCS); Thermal Control Subsystem (TCS); Water Removal Subsystem (WRS); and Power Reactant Storage and Distribution System (PRSDS). The IOA analysis process utilized available EPD and C/EPG hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.

  19. Beyond Valence and Magnitude: a Flexible Evaluative Coding System in the Brain

    PubMed Central

    Gu, Ruolei; Lei, Zhihui; Broster, Lucas; Wu, Tingting; Jiang, Yang; Luo, Yue-jia

    2013-01-01

    Outcome evaluation is a cognitive process that plays an important role in our daily lives. In most paradigms utilized in the field of experimental psychology, outcome valence and outcome magnitude are the two major features investigated. The classical “independent coding model” suggest that outcome valence and outcome magnitude are evaluated by separate neural mechanisms that may be mapped onto discrete event-related potential (ERP) components: feedback-related negativity (FRN) and the P3, respectively. To examine this model, we presented outcome valence and magnitude sequentially rather than simultaneously. The results reveal that when only outcome valence or magnitude is known, both the FRN and the P3 encode that outcome feature; when both aspects of outcome are known, the cognitive functions of the two components dissociate: the FRN responds to the information available in the current context, while the P3 pattern depends on outcome presentation sequence. The current study indicates that the human evaluative system, indexed in part by the FRN and the P3, is more flexible than previous theories suggested. PMID:22019775

  20. Depressive symptoms predict cognitive decline and dementia in older people independently of cerebral white matter changes: the LADIS study.

    PubMed

    Verdelho, Ana; Madureira, Sofia; Moleiro, Carla; Ferro, José M; O'Brien, John T; Poggesi, Anna; Pantoni, Leonardo; Fazekas, Franz; Scheltens, Philip; Waldemar, Gunhild; Wallin, Anders; Erkinjuntti, Timo; Inzitari, Domenico

    2013-11-01

    Depressive symptoms (DS) have been associated with increased risk of cognitive decline. Our aim was to evaluate the longitudinal influence of DS on cognition in independent older people, accounting for the severity of white matter changes (WMC). The LADIS (Leukoaraiosis And DISability in the elderly) prospective study evaluated the impact of WMC on the transition of independent older subjects into disability. Subjects were evaluated annually over a 3 year period with a comprehensive clinical and neuropsychological evaluation. Previous episodes of depression and current DS were assessed during each interview. Severity of DS was assessed using the self-rated 15 item Geriatric Depression Scale. A neuropsychological battery and clinical criteria for cognitive impairments were applied in all clinical visits, and cognitive compound measures were made based on neuropsychological results. MRI was performed at baseline and at year 3. 639 subjects were included (74.1 ± 5 years old, 55% women, 9.6 ± 3.8 years of schooling). Dementia was diagnosed in 90 patients and cognitive impairment not dementia in 147 patients at the last clinical evaluation. DS were an independent predictor of cognitive impairment (dementia and not dementia) during follow-up, independent of the effect of the severity of WMC, medial temporal lobe atrophy, age, education or global cognitive function at baseline. DS are associated with an increase risk of cognitive decline, independent of the effect of WMC, probably due to an additive or synergistic effect. In this context, DS probably represent a subtle ongoing organic dysfunction.

  1. A Clash of Cultures: Improving the "Fit" between Evaluative Independence and the Political Requirements of a Democratic Society

    ERIC Educational Resources Information Center

    Chelimsky, Eleanor

    2008-01-01

    This article presents a plenary address wherein the author talks about cultural clashes, about what happens when evaluation meets politics. In her address, the author talks about the kinds of clashes that occur on a regular basis between evaluative independence and the political culture it challenges, along with possible ways to predict, parry, or…

  2. The personal receiving document management and the realization of email function in OAS

    NASA Astrophysics Data System (ADS)

    Li, Biqing; Li, Zhao

    2017-05-01

    This software is an independent software system, suitable for small and medium enterprises, contains personal office, scientific research project management and system management functions, independently run in relevant environment, and to solve practical needs. This software is an independent software system, using the current popular B/S (browser/server) structure and ASP.NET technology development, using the Windows 7 operating system, Microsoft SQL Server2005 Visual2008 and database as a development platform, suitable for small and medium enterprises, contains personal office, scientific research project management and system management functions, independently run in relevant environment, and to solve practical needs.

  3. Field monitoring versus individual miner dosimetry of radon daughter products in mines.

    PubMed

    Domański, T; Kluszczyński, D; Olszewski, J; Chruscielewski, W

    1989-01-01

    The paper presents the results realised simultaneously by two different and independent systems of measurement of an assessment of miners' exposure to radon daughter products which naturally occur in the air of mines. The first one, called the Air Sampling System (ASS), was based on the field monitoring of radon progeny in air, the second one, called the Individual Dosimetry System (IDS), was based on the individual dosimeters worn by miners. Experimental comparison of these two systems has been conducted for six years in eleven Polish underground metal-ore mines. This study reveals that no correlation exists between the concentration and annual miners' exposures evaluated by the ASS and IDS. The ratio ASS/IDS for mine population varies from 11.0 to 0.14 in respect of annual concentration means, and in respect to annual exposures, this ratio varies from 4.5 to 0.14. The conclusion to be drawn from six years' observation and comparison of both systems is that correct and true evaluation of miners' exposure to radon progeny can be made only by the use of the Individual Dosimetry System, since the Air Sampling System is too sensitive and too dependent on the Strategy of sampling and its radiation.

  4. Study of structural active cooling and heat sink systems for space shuttle

    NASA Technical Reports Server (NTRS)

    1972-01-01

    This technology investigation was conducted to evaluate the feasibility of a number of thermal protection systems (TPS) concepts which are alternate candidates to the space shuttle baseline TPS. Four independent tasks were performed. Task 1 consisted of an in-depth evaluation of active structural cooling of the space shuttle orbiter. In Task 2, heat sink concepts for the booster were studied to identify and postulate solutions for design problems unique to heat sink TPS. Task 3 consisted of a feasibility demonstration test of a phase change material (PCM) incorporated into a reusable surface insulation (RSI) thermal protection system for the shuttle orbiter. In Task 4 the feasibility of heat pipes for stagnation region cooling was studied for the booster and the orbiter. Designs were developed for the orbiter leading edge and used in trade studies of leading edge concepts. At the time this program was initiated, a 2-stage fully reusable shuttle system was envisioned; therefore, the majority of the tasks were focused on the fully reusable system environments. Subsequently, a number of alternate shuttle system approaches, with potential for reduced shuttle system development funding requirements, were proposed. Where practicable, appropriate shifts in emphasis and task scoping were made to reflect these changes.

  5. Musculoskeletal system pain and related factors in mothers of children with cerebral palsy.

    PubMed

    Terzi, Rabia; Tan, Gülten

    2016-01-01

    The aim of the present study was to identify prevalence of musculoskeletal system diseases and related factors among mothers of children with cerebral palsy. Eighty-five mothers of children with cerebral palsy were included as the treatment group, and 42 mothers of healthy children were included as the control group. Sociodemographic characteristics of all subjects were recorded. Musculoskeletal system pain was evaluated by the standardized Nordic Musculoskeletal Questionnaire, and level of depression was evaluated according to Beck's Depression Scale. Musculoskeletal system pain and depression scores of the treatment group were significantly higher than those of the control group. Most frequently reported by mothers in the treatment group was low back pain (44.7%). In multiple regression analysis, number of children, age, and functional level of the child with cerebral palsy, as well as depression level of the mother were identified as independent risk factors for musculoskeletal system pain. Mothers of children with cerebral palsy are at higher risk for musculoskeletal system pain and depression. Prevalence of musculoskeletal system pain in these mothers, especially those with older children who have lower functional statuses, should be kept in mind.

  6. The Independence and Interdependence of Coacting Observers in Regard to Performance Efficiency, Workload, and Stress in a Vigilance Task

    DTIC Science & Technology

    2016-09-01

    independence/ dependence , evaluation apprehension, workload, stress 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT: SAR 18. NUMBER...indepen- dence/ dependence , evaluation apprehension, workload, stress IntroductIon Vigilance or sustained attention tasks require observers to maintain

  7. 78 FR 36750 - Information Collection; Submission for OMB Review, Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-19

    ... (ICR) entitled Senior Corps Independent Living Impact Evaluation Study for review and approval in... Independent Living Impact Evaluation Study. This project will assess the impact of the Senior Companion Program on clients' self-efficacy, life satisfaction, and perceived social ties and social supports...

  8. Assessment of Stirling Technology Has Provided Critical Data Leading Toward Flight Readiness of the Stirling Converter

    NASA Technical Reports Server (NTRS)

    Thieme, Lanny G.

    2001-01-01

    The NASA Glenn Research Center is supporting the development of a Stirling converter with the Department of Energy (DOE, Germantown, Maryland) for an advanced Stirling Radioisotope Power System (SRPS) to provide spacecraft onboard electric power for NASA space science missions. A key technology assessment completed by Glenn and DOE has led to the SRPS being identified as a high-efficiency power source for such deep space missions as the Europa Orbiter and the Solar Probe. In addition, the Stirling system is now being considered for unmanned Mars rovers, especially where mission profiles may exclude the use of photovoltaic power systems, such as exploration at high Martian latitudes or for missions of long duration. The SRPS efficiency of over 20 percent will reduce the required amount of radioisotope by more than a factor of 3 in comparison to current radioisotope thermoelectric generators. This significantly reduces radioisotope cost, radiological inventory, and system cost, and it provides efficient use of scarce radioisotope resources. In support of this technology assessment, Glenn conducted a series of independent evaluations and tests to determine the technology readiness of a 55-We Stirling converter developed by Stirling Technology Company (Kennewick, Washington) and DOE. Key areas evaluated by Glenn included: 1) Radiation tolerance of materials; 2) Random vibration testing of the Stirling converter in Glenn's Structural Dynamics Lab to simulate operation in the launch environment; 3) Electromagnetic interference and compatibility (EMI/EMC) of the converter operating in Glenn's EMI lab; Independent failure modes, effects, and criticality analysis, and life and reliability 4. Independent failure modes, effects, and criticality analysis, and life and reliability assessment; and 5) SRPS cost estimate. The data from these evaluations were presented to NASA Headquarters and the Jet Propulsion Laboratory mission office by a joint industry/Government team consisting of DOE, Glenn, and Lockheed Martin Astronautics. This team concluded that there are no technical reasons that would rule out using the Stirling converter for deep space missions. As a direct result of the successful testing at Glenn, the DOE/Stirling Technology Company 55-We Stirling converter has been baselined for the SRPS. Glenn is now continuing an in-house project to assist in developing the Stirling converter for readiness for space qualification and mission implementation. As part of this effort, the Stirling converter will be further characterized under launch environment random vibration testing, methods to reduce converter EMI will be developed, and an independent performance verification will be completed. Converter life assessment and permanent magnet aging characterization tasks are also underway. Substitute organic materials for the linear alternator and piston bearing coatings for use in a high-radiation environment have been identified and have now been incorporated in Stirling converters built by Stirling Technology Company for Glenn. Electromagnetic and thermal finite element analyses for the alternator are also being conducted.

  9. NREL, California Independent System Operator, and First Solar | Energy

    Science.gov Websites

    Solar NREL, California Independent System Operator, and First Solar Demonstrate Essential Reliability Services with Utility-Scale Solar NREL, the California Independent System Operator (CAISO), and First Solar conducted a demonstration project on a large utility-scale photovoltaic (PV) power plant in California to

  10. 78 FR 79690 - California Independent System Operator Corporation; Notice of Filing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-31

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL05-146-008] California Independent System Operator Corporation; Notice of Filing Take notice that on December 20, 2013, the California Independent System Operator Corporation (CAISO) filed a refund report to be made by the CAISO consistent with the Order on Remand (Order)...

  11. 78 FR 25740 - Meridian Energy USA, Inc. v. California Independent System Operator Corporation; Notice of Filing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-02

    ... Energy USA, Inc. v. California Independent System Operator Corporation; Notice of Filing Take notice that... Appendix Y of the California Independent System Operator Corp. (CAISO) tariff to defer the second posting of Interconnection Financial Security for the Jacobs Canal Solar Farm, Laurel West Solar Farm, and...

  12. Implant detectibility of intervertebral disc spacers in post fusion MRI: evaluation of the MRI scan quality by using a scoring system--an in vitro study.

    PubMed

    Ernstberger, Thorsten; Heidrich, Gabert; Schultz, Wolfgang; Grabbe, Eckhardt

    2007-02-01

    Intervertebral spacers for anterior spine fusion are made of different materials, such as titanium and cobalt chromium alloys and carbon fiber-reinforced polymers. Implant-related susceptibility artifacts can decrease the quality of MRI scans. The aim of this cadaveric study was to demonstrate the extent that implant-related MRI artifacting affects the postfusion differentiation of determined regions of interest (ROIs). In six cadaveric porcine spines, we evaluated the postimplantation MRI scans of a titanium, cobalt-chromium and carbon spacer that differed in shape and surface qualities. A spacer made of human cortical bone was used as a control. A defined evaluation unit was divided into ROIs to characterize the spinal canal as well as the intervertebral disc space. Considering 15 different MRI sequences read independently by an interobserver-validated team of specialists the artifact-affected image quality of the median MRI slice was rated on a score of 0-3. A maximum score of 18 points (100%) for the determined ROIs was possible. Turbo spin echo sequences produced the best scores for all spacers and the control. Only the control achieved a score of 100%. For the determined ROI maximum scores for the cobalt-chromium, titanium and carbon spacers were 24%, 32% and 84%, respectively. By using favored T1 TSE sequences the carbon spacer showed a clear advantage in postfusion spinal imaging. Independent of artifact dimensions, the scoring system used allowed us to create an implant-related ranking of MRI scan quality in reference to the bone control.

  13. Perspective: NutriGrade: A Scoring System to Assess and Judge the Meta-Evidence of Randomized Controlled Trials and Cohort Studies in Nutrition Research.

    PubMed

    Schwingshackl, Lukas; Knüppel, Sven; Schwedhelm, Carolina; Hoffmann, Georg; Missbach, Benjamin; Stelmach-Mardas, Marta; Dietrich, Stefan; Eichelmann, Fabian; Kontopantelis, Evangelos; Iqbal, Khalid; Aleksandrova, Krasimira; Lorkowski, Stefan; Leitzmann, Michael F; Kroke, Anja; Boeing, Heiner

    2016-11-01

    The objective of this study was to develop a scoring system (NutriGrade) to evaluate the quality of evidence of randomized controlled trial (RCT) and cohort study meta-analyses in nutrition research, building upon previous tools and expert recommendations. NutriGrade aims to assess the meta-evidence of an association or effect between different nutrition factors and outcomes, taking into account nutrition research-specific requirements not considered by other tools. In a pretest study, 6 randomly selected meta-analyses investigating diet-disease relations were evaluated with NutriGrade by 5 independent raters. After revision, NutriGrade was applied by the same raters to 30 randomly selected meta-analyses in the same thematic area. The reliability of ratings of NutriGrade items was calculated with the use of a multirater κ, and reliability of the total (summed scores) was calculated with the use of intraclass correlation coefficients (ICCs). The following categories for meta-evidence evaluation were established: high (8-10), moderate (6-7.99), low (4-5.99), and very low (0-3.99). The NutriGrade scoring system (maximum of 10 points) comprises the following items: 1) risk of bias, study quality, and study limitations, 2) precision, 3) heterogeneity, 4) directness, 5) publication bias, 6) funding bias, 7) study design, 8) effect size, and 9) dose-response. The NutriGrade score varied between 2.9 (very low meta-evidence) and 8.8 (high meta-evidence) for meta-analyses of RCTs, and it ranged between 3.1 and 8.8 for meta-analyses of cohort studies. The κ value of the ratings for each scoring item varied from 0.32 (95% CI: 0.22, 0.42) for risk of bias for cohort studies and 0.95 (95% CI: 0.91, 0.99) for study design, with a mean κ of 0.66 (95% CI: 0.53, 0.79). The ICC of the total score was 0.81 (95% CI: 0.69, 0.90). The NutriGrade scoring system showed good agreement and reliability. The initial findings regarding the performance of this newly established scoring system need further evaluation in independent analyses. © 2016 American Society for Nutrition.

  14. Perspective: NutriGrade: A Scoring System to Assess and Judge the Meta-Evidence of Randomized Controlled Trials and Cohort Studies in Nutrition Research123

    PubMed Central

    Knüppel, Sven; Schwedhelm, Carolina; Hoffmann, Georg; Missbach, Benjamin; Stelmach-Mardas, Marta; Dietrich, Stefan; Eichelmann, Fabian; Kontopanteils, Evangelos; Iqbal, Khalid; Aleksandrova, Krasimira; Lorkowski, Stefan; Leitzmann, Michael F; Kroke, Anja; Boeing, Heiner

    2016-01-01

    The objective of this study was to develop a scoring system (NutriGrade) to evaluate the quality of evidence of randomized controlled trial (RCT) and cohort study meta-analyses in nutrition research, building upon previous tools and expert recommendations. NutriGrade aims to assess the meta-evidence of an association or effect between different nutrition factors and outcomes, taking into account nutrition research–specific requirements not considered by other tools. In a pretest study, 6 randomly selected meta-analyses investigating diet–disease relations were evaluated with NutriGrade by 5 independent raters. After revision, NutriGrade was applied by the same raters to 30 randomly selected meta-analyses in the same thematic area. The reliability of ratings of NutriGrade items was calculated with the use of a multirater κ, and reliability of the total (summed scores) was calculated with the use of intraclass correlation coefficients (ICCs). The following categories for meta-evidence evaluation were established: high (8–10), moderate (6–7.99), low (4–5.99), and very low (0–3.99). The NutriGrade scoring system (maximum of 10 points) comprises the following items: 1) risk of bias, study quality, and study limitations, 2) precision, 3) heterogeneity, 4) directness, 5) publication bias, 6) funding bias, 7) study design, 8) effect size, and 9) dose-response. The NutriGrade score varied between 2.9 (very low meta-evidence) and 8.8 (high meta-evidence) for meta-analyses of RCTs, and it ranged between 3.1 and 8.8 for meta-analyses of cohort studies. The κ value of the ratings for each scoring item varied from 0.32 (95% CI: 0.22, 0.42) for risk of bias for cohort studies and 0.95 (95% CI: 0.91, 0.99) for study design, with a mean κ of 0.66 (95% CI: 0.53, 0.79). The ICC of the total score was 0.81 (95% CI: 0.69, 0.90). The NutriGrade scoring system showed good agreement and reliability. The initial findings regarding the performance of this newly established scoring system need further evaluation in independent analyses. PMID:28140319

  15. From Sensory Signals to Modality-Independent Conceptual Representations: A Probabilistic Language of Thought Approach

    PubMed Central

    Erdogan, Goker; Yildirim, Ilker; Jacobs, Robert A.

    2015-01-01

    People learn modality-independent, conceptual representations from modality-specific sensory signals. Here, we hypothesize that any system that accomplishes this feat will include three components: a representational language for characterizing modality-independent representations, a set of sensory-specific forward models for mapping from modality-independent representations to sensory signals, and an inference algorithm for inverting forward models—that is, an algorithm for using sensory signals to infer modality-independent representations. To evaluate this hypothesis, we instantiate it in the form of a computational model that learns object shape representations from visual and/or haptic signals. The model uses a probabilistic grammar to characterize modality-independent representations of object shape, uses a computer graphics toolkit and a human hand simulator to map from object representations to visual and haptic features, respectively, and uses a Bayesian inference algorithm to infer modality-independent object representations from visual and/or haptic signals. Simulation results show that the model infers identical object representations when an object is viewed, grasped, or both. That is, the model’s percepts are modality invariant. We also report the results of an experiment in which different subjects rated the similarity of pairs of objects in different sensory conditions, and show that the model provides a very accurate account of subjects’ ratings. Conceptually, this research significantly contributes to our understanding of modality invariance, an important type of perceptual constancy, by demonstrating how modality-independent representations can be acquired and used. Methodologically, it provides an important contribution to cognitive modeling, particularly an emerging probabilistic language-of-thought approach, by showing how symbolic and statistical approaches can be combined in order to understand aspects of human perception. PMID:26554704

  16. Retrospective Evaluation of Safety, Efficacy and Risk Factors for Pneumothorax in Simultaneous Localizations of Multiple Pulmonary Nodules Using Hook Wire System.

    PubMed

    Zhong, Yan; Xu, Xiao-Quan; Pan, Xiang-Long; Zhang, Wei; Xu, Hai; Yuan, Mei; Kong, Ling-Yan; Pu, Xue-Hui; Chen, Liang; Yu, Tong-Fu

    2017-09-01

    To evaluate the safety and efficacy of the hook wire system in the simultaneous localizations for multiple pulmonary nodules (PNs) before video-assisted thoracoscopic surgery (VATS), and to clarify the risk factors for pneumothorax associated with the localization procedure. Between January 2010 and February 2016, 67 patients (147 nodules, Group A) underwent simultaneous localizations for multiple PNs using a hook wire system. The demographic, localization procedure-related information and the occurrence rate of pneumothorax were assessed and compared with a control group (349 patients, 349 nodules, Group B). Multivariate logistic regression analyses were used to determine the risk factors for pneumothorax during the localization procedure. All the 147 nodules were successfully localized. Four (2.7%) hook wires dislodged before VATS procedure, but all these four lesions were successfully resected according to the insertion route of hook wire. Pathological diagnoses were acquired for all 147 nodules. Compared with Group B, Group A demonstrated significantly longer procedure time (p < 0.001) and higher occurrence rate of pneumothorax (p = 0.019). Multivariate logistic regression analysis indicated that position change during localization procedure (OR 2.675, p = 0.021) and the nodules located in the ipsilateral lung (OR 9.404, p < 0.001) were independent risk factors for pneumothorax. Simultaneous localizations for multiple PNs using a hook wire system before VATS procedure were safe and effective. Compared with localization for single PN, simultaneous localizations for multiple PNs were prone to the occurrence of pneumothorax. Position change during localization procedure and the nodules located in the ipsilateral lung were independent risk factors for pneumothorax.

  17. Infiltration of diametrically polarized macrophages predicts overall survival of patients with gastric cancer after surgical resection.

    PubMed

    Zhang, Heng; Wang, Xuefei; Shen, Zhenbin; Xu, Jiejie; Qin, Jing; Sun, Yihong

    2015-10-01

    Tumor-associated macrophages (TAMs), the most predominant tumor-infiltrating immune cells, are emerging prognostic factors and therapeutic targets for personalized therapy against malignant neoplasms. We aimed to evaluate the prognostic significance of diametrically polarized TAMs in gastric cancer and generate a predictive nomogram to refine a risk stratification system. We evaluated polarized functional status of infiltrated TAMs by immunohistochemical staining of CD68, CD11c, and CD206 in 180 consecutive gastric cancer patients from Zhongshan Hospital, Shanghai, China. Prognostic values were assessed in these patients. We created a predictive nomogram by integrating polarized TAMs with the TNM staging system for overall survival of gastric cancer patients. CD68(+) TAMs display polarized programs comprising CD11c(+) proinflammatory macrophages (M1) and CD206(+) immunosuppressive macrophages (M2) that configure versatile infiltration files in gastric cancer. CD11c(+) TAMs negatively correlated with lymph node metastasis (p = 0.012), whereas CD206(+) TAMs correlated with the Lauren classification (p = 0.031). No prognostic difference was observed for overall survival for CD68 density (high vs low, p = 0.1031), whereas high versus low CD11c density (p < 0.0001) and low vs high CD206 density (p = 0.0105) indicate better overall survival. Multivariate Cox regression analysis identified CD11c and CD206 as independent prognostic factors (p < 0.001 and p = 0.030, respectively), which could be integrated with the TNM staging system to generate a predictive nomogram for patient outcomes. Infiltration of polarized TAMs, a novel identified independent prognostic factor, could be combined with the TNM stage to refine a risk stratification system and better stratify patients with different prognosis. Tipping TAMs to an antitumoral phenotype might be a promising therapeutic target for postoperative treatment.

  18. Evaluation of the Revised International Staging System in an independent cohort of unselected patients with multiple myeloma

    PubMed Central

    Kastritis, Efstathios; Terpos, Evangelos; Roussou, Maria; Gavriatopoulou, Maria; Migkou, Magdalini; Eleutherakis-Papaiakovou, Evangelos; Fotiou, Despoina; Ziogas, Dimitrios; Panagiotidis, Ioannis; Kafantari, Eftychia; Giannouli, Stavroula; Zomas, Athanasios; Konstantopoulos, Konstantinos; Dimopoulos, Meletios A.

    2017-01-01

    The Revised International Staging System (R-ISS) was recently introduced in order to improve risk stratification over that provided by the widely used standard International Staging System. In addition to the parameters of the standard system, the R-ISS incorporates the presence of chromosomal abnormalities detected by interphase fluorescence in situ hybridization [t(4;14), t(14;16) and del17p] and elevated serum lactate dehydrogenase. The R-ISS was formulated on the basis of a large dataset of selected patients who had participated in clinical trials and has not been validated in an independent cohort of unselected patients. Thus, we evaluated the R-ISS in 475 consecutive, unselected patients, treated in a single center. Our patients were older and more often had severe renal dysfunction than those in the original publication on the R-ISS. As regards distribution by group, 18% had R-ISS-1, 64.5% R-ISS-2 and 18% R-ISS-3. According to R-ISS group, the 5-year survival rate was 77%, 53% and 19% for R-ISS-1, -2 and -3, respectively (P<0.001). The R-ISS could identify three groups with distinct outcomes among patients treated with or without autologous stem cell transplantation, among those treated with either bortezomib-based or immunomodulatory drug-based primary therapy and in patients ≤65, 66–75 or >75 years. However, in patients with severe renal dysfunction the distinction between groups was less clear. In conclusion, our data in consecutive, unselected patients, with differences in the characteristics and treatment approaches compared to the original International Myeloma Working Group cohort, verified that R-ISS is a robust tool for risk stratification of newly diagnosed patients with symptomatic myeloma. PMID:27789676

  19. Assessment of vulnerable older adults' physical function according to the Japanese Long-Term Care Insurance (LTCI) system and Fried's criteria for frailty syndrome.

    PubMed

    Nemoto, Miyuki; Yabushita, Noriko; Kim, Mi-Ji; Matsuo, Tomoaki; Seino, Satoshi; Tanaka, Kiyoji

    2012-01-01

    This study aimed to evaluate the physical frailty status of vulnerable older adults as classified in the Japanese LTCI system and to compare this with Fried's definition. A total of 444 older adults were classified based on the LTCI system as independent, vulnerable, or dependent, and 400 of these participants also fit Fried's criteria for not frail, pre-frail or frail. We evaluated their physical function with a 12 item physical function test. We derived a physical function score (PFS) from these 12 items and a principal component analysis was used to make comparisons. The receiver operating characteristic (ROC) curve analysis was performed to identify the sensitivity and specificity of the PFS cut-off points to distinguish the dependent category from the other categories. We found significant differences and a hierarchical order for the PFSs among the three groups of the LTCI system (the independent, 0.41 ± 0.54; the vulnerable, -0.40 ± 0.76; and the dependent, -1.49 ± 0.73) and of Fried's definition (not frail, 0.50 ± 0.51; pre frail, -0.11 ± 0.63; and frail, -1.25 ± 0.98). The optimal cut-off value (OCV) was -0.593. This study showed that the range of physical function of people considered frail category (pre-frail, vulnerable, and frail) is wide and overlapping. That is, the physical function of vulnerable older adults is worse than the pre-frail, but better than the frail. To better recognize older adults in need of greater support, the vulnerable should also receive assessment of their frailty status according to Fried's definition. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  20. Development and Psychometric Evaluation of the Independent School Teacher Development Inventory

    ERIC Educational Resources Information Center

    Murray, John M.

    2012-01-01

    In this study the author examined the psychometrics of an instrument, the Independent School Teacher Development Inventory, designed to assess the professional learning opportunities in U.S. independent schools. The inventory was sent to 3,422 independent school administrators and of these, 2,474 returned completed surveys. Exploratory factor…

  1. Independent evaluation of light-vehicle safety applications based on vehicle-to-vehicle communications used in the 2012-2013 safety pilot model deployment

    DOT National Transportation Integrated Search

    2015-12-01

    This report presents the methodology and results of the independent evaluation of safety applications for passenger vehicles in the 2012-2013 Safety Pilot Model Deployment, part of the United States Department of Transportations Intelligent Transp...

  2. Evaluation of TDRSS-user orbit determination accuracy using batch least-squares and sequential methods

    NASA Technical Reports Server (NTRS)

    Oza, D. H.; Jones, T. L.; Hodjatzadeh, M.; Samii, M. V.; Doll, C. E.; Hart, R. C.; Mistretta, G. D.

    1991-01-01

    The development of the Real-Time Orbit Determination/Enhanced (RTOD/E) system as a prototype system for sequential orbit determination on a Disk Operating System (DOS) based Personal Computer (PC) is addressed. The results of a study to compare the orbit determination accuracy of a Tracking and Data Relay Satellite System (TDRSS) user spacecraft obtained using RTOD/E with the accuracy of an established batch least squares system, the Goddard Trajectory Determination System (GTDS), is addressed. Independent assessments were made to examine the consistencies of results obtained by the batch and sequential methods. Comparisons were made between the forward filtered RTOD/E orbit solutions and definitive GTDS orbit solutions for the Earth Radiation Budget Satellite (ERBS); the maximum solution differences were less than 25 m after the filter had reached steady state.

  3. [Implementation of a new electronic patient record in surgery].

    PubMed

    Eggli, S; Holm, J

    2001-12-01

    The increasing amount of clinical data, intensified interest of patients in medical information, medical quality management and the recent cost explosion in health care systems have forced medical institutions to improve their strategy in handling medical data. In the orthopedic department (3,600 surgeries, 75 beds, 14,000 consultations) software application for comprehensive patient data management has been developed. When implementing the electronic patient history following criteria were evaluated: 1. software evaluation, 2. implementation, 3. work flow, 4. data security/system stability. In the first phase the functional character was defined. Implementation required 3 months after parametrization. The expense amounted to 130,000 DM (30 clients). The training requirements were one afternoon for the secretaries and a 2-h session for the residents. The access speed on medically relevant data averaged under 3 s. The average saving in working hours was approximately 5 h/week for the secretaries and 4 h/week for the residents. The saving in paper amounted to 36,000 sheets/year. In 3 operational years there were 3 server breakdowns. Evaluation of the saving on working hours showed that such a system can amortize within a year. The latest improvements in hardware and software technology made the electronic medical record with integrated quality-control practicable without massive expenditure. The system supplies an extensive platform of information for patient treatment and an instrument to evaluate the efficiency of therapy strategies independent of the clinical field.

  4. Qualitative fusion technique based on information poor system and its application to factor analysis for vibration of rolling bearings

    NASA Astrophysics Data System (ADS)

    Xia, Xintao; Wang, Zhongyu

    2008-10-01

    For some methods of stability analysis of a system using statistics, it is difficult to resolve the problems of unknown probability distribution and small sample. Therefore, a novel method is proposed in this paper to resolve these problems. This method is independent of probability distribution, and is useful for small sample systems. After rearrangement of the original data series, the order difference and two polynomial membership functions are introduced to estimate the true value, the lower bound and the supper bound of the system using fuzzy-set theory. Then empirical distribution function is investigated to ensure confidence level above 95%, and the degree of similarity is presented to evaluate stability of the system. Cases of computer simulation investigate stable systems with various probability distribution, unstable systems with linear systematic errors and periodic systematic errors and some mixed systems. The method of analysis for systematic stability is approved.

  5. [Evaluation of Research Experience Based on the Type of Degree Completed for the Development of Pharmacist-Scientists].

    PubMed

    Ikemura, Mai; Hashida, Tohru

    2016-01-01

      "Pharmacist-scientists" are needed in the clinical setting. However, research competency, including logical thinking, differs among pharmacists. This difference stems from the varying experience of research during university and graduate school. Thus, to ascertain the research experience within different educational systems, we evaluated pharmacists in Kobe City Medical Center General Hospital. In most instances, there was a direct correlation between the duration of research (in the laboratory at university or graduate school), and research experience gained, such as independent thinking and presentations at seminars or academic conferences. Respondents who graduated from the recently introduced 6-year pharmaceutical science course had less research experience than those who graduated with a combination 4-year degree and subsequent master's course. Conversely, the number of presentations at academic conferences and the number of published papers postgraduation were independent of research experience during university and graduate school. These results indicate that there is a considerable difference in the research experience during university and graduate school among pharmacists, and this is likely to impact their pharmaceutical skills.

  6. A multifaceted independent performance analysis of facial subspace recognition algorithms.

    PubMed

    Bajwa, Usama Ijaz; Taj, Imtiaz Ahmad; Anwar, Muhammad Waqas; Wang, Xuan

    2013-01-01

    Face recognition has emerged as the fastest growing biometric technology and has expanded a lot in the last few years. Many new algorithms and commercial systems have been proposed and developed. Most of them use Principal Component Analysis (PCA) as a base for their techniques. Different and even conflicting results have been reported by researchers comparing these algorithms. The purpose of this study is to have an independent comparative analysis considering both performance and computational complexity of six appearance based face recognition algorithms namely PCA, 2DPCA, A2DPCA, (2D)(2)PCA, LPP and 2DLPP under equal working conditions. This study was motivated due to the lack of unbiased comprehensive comparative analysis of some recent subspace methods with diverse distance metric combinations. For comparison with other studies, FERET, ORL and YALE databases have been used with evaluation criteria as of FERET evaluations which closely simulate real life scenarios. A comparison of results with previous studies is performed and anomalies are reported. An important contribution of this study is that it presents the suitable performance conditions for each of the algorithms under consideration.

  7. An Operator Perspective from a Facility Evaluation of an RFID-Based UF6 Cylinder Accounting and Tracking System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martyn, Rose; Fitzgerald, Peter; Stehle, Nicholas D

    An operational field test of a Radio-Frequency Identification (RFID) system for tracking and accounting UF6 cylinders was conducted at the Global Nuclear Fuel Americas (GNF) fuel fabrication plant in 2009. The Cylinder Accountability and Tracking System (CATS) was designed and deployed by Oak Ridge National Laboratory (ORNL) and evaluated in cooperation with GNF. The system required that passive RFID be attached to several UF6 30B cylinders as they were received at the site; then the cylinders were tracked as they proceeded to interim storage, to processing in an autoclave, and eventually to disposition from the site. This CATS deployment alsomore » provided a direct integration of scale data from the site accountability scales. The integration of this information into the tracking data provided an attribute for additional safeguards for evaluation. The field test provided insight into the advantages and challenges of using RFID at an operating nuclear facility. The RFID system allowed operators to interact with the technology and demonstrated the survivability of the tags and reader equipment in the process environment. This paper will provide the operator perspective on utilizing RFID technology for locating cylinders within the facility, thereby tracking the cylinders for process and for Material Control & Accounting functions. The paper also will present the operator viewpoint on RFID implemented as an independent safeguards system.« less

  8. Paying health workers for performance in Battagram district, Pakistan

    PubMed Central

    2011-01-01

    Background There is a growing interest in using pay-for-performance mechanisms in low and middle-income countries in order to improve the performance of health care providers. However, at present there is a dearth of independent evaluations of such approaches which can guide understanding of their potential and risks in differing contexts. This article presents the results of an evaluation of a project managed by an international non-governmental organisation in one district of Pakistan. It aims to contribute to learning about the design and implementation of pay-for-performance systems and their impact on health worker motivation. Methods Quantitative analysis was conducted of health management information system (HMIS) data, financial records, and project documents covering the period 2007-2010. Key informant interviews were carried out with stakeholders at all levels. At facility level, in-depth interviews were held, as were focus group discussions with staff and community members. Results The wider project in Battagram had contributed to rebuilding district health services at a cost of less than US$4.5 per capita and achieved growth in outputs. Staff, managers and clients were appreciative of the gains in availability and quality of services. However, the role that the performance-based incentive (PBI) component played was less clear--PBI formed a relatively small component of pay, and did not increase in line with outputs. There was little evidence from interviews and data that the conditional element of the PBIs influenced behaviour. They were appreciated as a top-up to pay, but remained low in relative terms, and only slightly and indirectly related to individual performance. Moreover, they were implemented independently of the wider health system and presented a clear challenge for longer term integration and sustainability. Conclusions Challenges for performance-based pay approaches include the balance of rewarding individual versus team efforts; reflecting process and outcome indicators; judging the right level of incentives; allowing for very different starting points and situations; designing a system which is simple enough for participants to comprehend; and the tension between independent monitoring and integration in a national system. Further documentation of process and cost-effectiveness, and careful examination of the wider impacts of paying for performance, are still needed. PMID:21982330

  9. Estimation of 3D reconstruction errors in a stereo-vision system

    NASA Astrophysics Data System (ADS)

    Belhaoua, A.; Kohler, S.; Hirsch, E.

    2009-06-01

    The paper presents an approach for error estimation for the various steps of an automated 3D vision-based reconstruction procedure of manufactured workpieces. The process is based on a priori planning of the task and built around a cognitive intelligent sensory system using so-called Situation Graph Trees (SGT) as a planning tool. Such an automated quality control system requires the coordination of a set of complex processes performing sequentially data acquisition, its quantitative evaluation and the comparison with a reference model (e.g., CAD object model) in order to evaluate quantitatively the object. To ensure efficient quality control, the aim is to be able to state if reconstruction results fulfill tolerance rules or not. Thus, the goal is to evaluate independently the error for each step of the stereo-vision based 3D reconstruction (e.g., for calibration, contour segmentation, matching and reconstruction) and then to estimate the error for the whole system. In this contribution, we analyze particularly the segmentation error due to localization errors for extracted edge points supposed to belong to lines and curves composing the outline of the workpiece under evaluation. The fitting parameters describing these geometric features are used as quality measure to determine confidence intervals and finally to estimate the segmentation errors. These errors are then propagated through the whole reconstruction procedure, enabling to evaluate their effect on the final 3D reconstruction result, specifically on position uncertainties. Lastly, analysis of these error estimates enables to evaluate the quality of the 3D reconstruction, as illustrated by the shown experimental results.

  10. 48 CFR 3.103 - Independent pricing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Independent pricing. 3.103 Section 3.103 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL IMPROPER BUSINESS PRACTICES AND PERSONAL CONFLICTS OF INTEREST Safeguards 3.103 Independent pricing. ...

  11. 75 FR 45106 - Notice of Attendance at NYISO Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-02

    .... EL07-39 and ER08-695, New York Independent System Operator, Inc. Docket No. EL09-57, Astoria Gas Turbine Power LLC v. New York Independent System Operator, Inc. Docket No. EL10-033, New York Independent...

  12. Independent Evaluation of The Bay Area Supply Depot Consolidation Prototype

    DTIC Science & Technology

    1991-12-01

    extra inventory to be added to the system. In effect, receipt processing timeliness balances the cost of receiving economically with the cost of holding...that could not be found because of incorrect balance information; the ICP thinks the stock is there, but the warehouse worker cannot locate it. It is a...reflect the overall accuracy of the balance or location 4While balance accuracy is also an important measure of record accuracy, it is not included here

  13. Feasibility of TBI Assessment Measures in a Field Environment: A Pilot Study for the Environmental Sensors in Training (ESiT) Project

    DTIC Science & Technology

    2016-12-22

    included assessments and instruments, descriptive statistics were calculated. Independent-samples t-tests were conducted using participant survey scores...integrity tests within a multimodal system. Both conditions included the Military Acute Concussion Evaluation (MACE) and an Ease-of-Use survey . Mean scores...for the Ease-of-Use survey and mean test administration times for each measure were compared. Administrative feedback was also considered for

  14. 78 FR 18334 - New York Independent System Operator, Inc.; Notice of Motion for Tariff Waiver and Expedited Action

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-26

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER13-1124-000] New York Independent System Operator, Inc.; Notice of Motion for Tariff Waiver and Expedited Action On March 15, 2013, New York Independent System Operator, Inc. (NYISO) filed a motion for limited tariff waivers of...

  15. A multicentre European registry to evaluate the Direct Flow Medical transcatheter aortic valve system for the treatment of patients with severe aortic stenosis.

    PubMed

    Naber, Christoph K; Pyxaras, Stylianos A; Ince, Hüseyin; Frambach, Peter; Colombo, Antonio; Butter, Christian; Gatto, Fernando; Hink, Ulrich; Nickenig, Georg; Bruschi, Giuseppe; Brueren, Guus; Tchétché, Didier; Den Heijer, Peter; Schillinger, Wolfgang; Scholtz, Smita; Van der Heyden, Jan; Lefèvre, Thierry; Gilard, Martine; Kuck, Karl-Heinz; Schofer, Joachim; Divchev, Dimitar; Baumgartner, Helmut; Asch, Federico; Wagner, Daniel; Latib, Azeem; De Marco, Federico; Kische, Stephan

    2016-12-10

    Our aim was to assess the clinical outcomes of the Direct Flow Medical Transcatheter Aortic Valve System (DFM-TAVS), when used in routine clinical practice. This is a prospective, open-label, multicentre, post-market registry of patients treated with DFM-TAVS according to approved commercial indications. Echocardiographic and angiographic data were evaluated by an independent core laboratory and adverse events were adjudicated and classified according to VARC-2 criteria by an independent clinical events committee. The primary endpoint was freedom from all-cause mortality at 30 days post procedure. Secondary endpoints included procedural, early safety and efficacy endpoints at 30 days. Two hundred and fifty patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) with the DFM-TAVS were enrolled in 21 European centres. The primary endpoint, freedom from all-cause mortality at 30 days, was met in 98% (245/250) of patients. Device success was 83.8%. Moderate or severe aortic regurgitation was reported in 3% of patients, and none/trace regurgitation in 73% of patients. Post-procedural permanent pacemaker implantation was performed in 30 patients (12.0%). The DFM-TAVS was associated with good short-term outcomes in this real-world registry. The low pacemaker and aortic regurgitation rates confirm the advantages of this next-generation transcatheter heart valve (THV).

  16. Irdis: A Digital Scene Storage And Processing System For Hardware-In-The-Loop Missile Testing

    NASA Astrophysics Data System (ADS)

    Sedlar, Michael F.; Griffith, Jerry A.

    1988-07-01

    This paper describes the implementation of a Seeker Evaluation and Test Simulation (SETS) Facility at Eglin Air Force Base. This facility will be used to evaluate imaging infrared (IIR) guided weapon systems by performing various types of laboratory tests. One such test is termed Hardware-in-the-Loop (HIL) simulation (Figure 1) in which the actual flight of a weapon system is simulated as closely as possible in the laboratory. As shown in the figure, there are four major elements in the HIL test environment; the weapon/sensor combination, an aerodynamic simulator, an imagery controller, and an infrared imagery system. The paper concentrates on the approaches and methodologies used in the imagery controller and infrared imaging system elements for generating scene information. For procurement purposes, these two elements have been combined into an Infrared Digital Injection System (IRDIS) which provides scene storage, processing, and output interface to drive a radiometric display device or to directly inject digital video into the weapon system (bypassing the sensor). The paper describes in detail how standard and custom image processing functions have been combined with off-the-shelf mass storage and computing devices to produce a system which provides high sample rates (greater than 90 Hz), a large terrain database, high weapon rates of change, and multiple independent targets. A photo based approach has been used to maximize terrain and target fidelity, thus providing a rich and complex scene for weapon/tracker evaluation.

  17. Communication behaviours of skilled and less skilled oncologists: a validation study of the Medical Interaction Process System (MIPS).

    PubMed

    Ford, Sarah; Hall, Angela

    2004-09-01

    The Medical Interaction Process System (MIPS) was originally developed in order to create a reliable observation tool for analysing doctor-patient encounters in the oncology setting. This paper reports a series of analyses carried out to establish whether the behaviour categories of the MIPS can discriminate between skilled and less skilled communicators. This involved the use of MIPS coded cancer consultations to compare the MIPS indices of 10 clinicians evaluated by an independent professional as skilled communicators with 10 who were considered less skilled. Eleven out of the 15 MIPS variables tested were able to distinguish the skilled from the less skilled group. Although limitations to the study are discussed, the results indicate that the MIPS has satisfactory discriminatory power and the results provide validity data that meet key objectives for developing the system. There is an ever-increasing need for reliable methods of assessing doctors' communication skills and evaluating medical interview teaching programmes. Copyright 2004 Elsevier Ireland Ltd.

  18. Evaluation of the educational value of YouTube videos about physical examination of the cardiovascular and respiratory systems.

    PubMed

    Azer, Samy A; Algrain, Hala A; AlKhelaif, Rana A; AlEshaiwi, Sarah M

    2013-11-13

    A number of studies have evaluated the educational contents of videos on YouTube. However, little analysis has been done on videos about physical examination. This study aimed to analyze YouTube videos about physical examination of the cardiovascular and respiratory systems. It was hypothesized that the educational standards of videos on YouTube would vary significantly. During the period from November 2, 2011 to December 2, 2011, YouTube was searched by three assessors for videos covering the clinical examination of the cardiovascular and respiratory systems. For each video, the following information was collected: title, authors, duration, number of viewers, and total number of days on YouTube. Using criteria comprising content, technical authority, and pedagogy parameters, videos were rated independently by three assessors and grouped into educationally useful and non-useful videos. A total of 1920 videos were screened. Only relevant videos covering the examination of adults in the English language were identified (n=56). Of these, 20 were found to be relevant to cardiovascular examinations and 36 to respiratory examinations. Further analysis revealed that 9 provided useful information on cardiovascular examinations and 7 on respiratory examinations: scoring mean 14.9 (SD 0.33) and mean 15.0 (SD 0.00), respectively. The other videos, 11 covering cardiovascular and 29 on respiratory examinations, were not useful educationally, scoring mean 11.1 (SD 1.08) and mean 11.2 (SD 1.29), respectively. The differences between these two categories were significant (P<.001 for both body systems). The concordance between the assessors on applying the criteria was 0.89, with a kappa score >.86. A small number of videos about physical examination of the cardiovascular and respiratory systems were identified as educationally useful; these videos can be used by medical students for independent learning and by clinical teachers as learning resources. The scoring system utilized by this study is simple, easy to apply, and could be used by other researchers on similar topics.

  19. Surfactant enhanced recovery of tetrachloroethylene from a porous medium containing low permeability lenses. 2. Numerical simulation.

    PubMed

    Rathfelder, K M; Abriola, L M; Taylor, T P; Pennell, K D

    2001-04-01

    A numerical model of surfactant enhanced solubilization was developed and applied to the simulation of nonaqueous phase liquid recovery in two-dimensional heterogeneous laboratory sand tank systems. Model parameters were derived from independent, small-scale, batch and column experiments. These parameters included viscosity, density, solubilization capacity, surfactant sorption, interfacial tension, permeability, capillary retention functions, and interphase mass transfer correlations. Model predictive capability was assessed for the evaluation of the micellar solubilization of tetrachloroethylene (PCE) in the two-dimensional systems. Predicted effluent concentrations and mass recovery agreed reasonably well with measured values. Accurate prediction of enhanced solubilization behavior in the sand tanks was found to require the incorporation of pore-scale, system-dependent, interphase mass transfer limitations, including an explicit representation of specific interfacial contact area. Predicted effluent concentrations and mass recovery were also found to depend strongly upon the initial NAPL entrapment configuration. Numerical results collectively indicate that enhanced solubilization processes in heterogeneous, laboratory sand tank systems can be successfully simulated using independently measured soil parameters and column-measured mass transfer coefficients, provided that permeability and NAPL distributions are accurately known. This implies that the accuracy of model predictions at the field scale will be constrained by our ability to quantify soil heterogeneity and NAPL distribution.

  20. The Reliability of a Standardized Reporting System for the Diagnosis of Appendicitis.

    PubMed

    Simianu, Vlad V; Shamitoff, Anna; Hippe, Daniel S; Godwin, Benjamin D; Shriki, Jabi E; Drake, Frederick T; O'Malley, Ryan B; Maximin, Suresh; Bastawrous, Sarah; Moshiri, Mariam; Lee, Jean H; Cuevas, Carlos; Dighe, Manjiri; Flum, David; Bhargava, Puneet

    Computed tomography (CT) is a fast and ubiquitous tool to evaluate intra-abdominal organs and diagnose appendicitis. However, traditional CT reporting does not necessarily capture the degree of uncertainty and indeterminate findings are still common. The purpose of this study was to evaluate the reproducibility of a standardized CT reporting system for appendicitis across a large population and the system's impact on radiologists' certainty in diagnosing appendicitis. Using a previously described standardized reporting system, eight radiologists retrospectively evaluated CT scans, blinded to all clinical information, in a stratified random sample of 237 patients from a larger cohort of patients imaged for possible appendicitis (2010-2014). Receiver operating characteristic (ROC) curves and the area under the ROC curve (AUC) were used to evaluate the diagnostic performance of readers for identifying appendicitis. Two-thirds of these scans were randomly selected to be independently read by a second reader, using the original CT reports to balance the number of positive, negative and indeterminate exams across all readers. Inter-reader agreement was evaluated. There were 113 patients with appendicitis (mean age 38, 67% male). Using the standardized report, radiologists were highly accurate at identifying appendicitis (AUC=0.968, 95%CI confidence interval: 0.95, 0.99. Inter-reader agreement was >80% for most objective findings, and certainty in diagnosing appendicitis was high and reproducible (AUC=0.955 and AUC=0.936 for the first and second readers, respectively). Using a standardized reporting system resulted in high reproducibility of objective CT findings for appendicitis and achieved high diagnostic accuracy in an at-risk population. Predictive tools based on this reporting system may further improve communication about certainty in diagnosis and guide patient management, especially when CT findings are indeterminate. Copyright © 2017 Elsevier Inc. All rights reserved.

Top