PERFORMANCE EVALUATION OF A PROTOTYPE ARCHITECT ANTIBODY ASSAY FOR BABESIA MICROTI.
Cheng, Kevin; Coller, Kelly E; Marohnic, Christopher C; Pfeiffer, Zachary A; Fino, James R; Elsing, Randee R; Bergsma, Janet; Marcinkus, Marilee A; Kar, Alak K; Gumbs, Orlando H; Otis, Kathy S; Fishpaugh, Jeffrey; Schultz, Phillip W; Pope, Mark R; Narvaez, Alfredo R; Wong, Susan J; Madison-Antenucci, Susan; Leary, Thomas P; Dawson, George J
2018-05-09
The tick-borne protozoan Babesia microti is responsible for more than 200 cases of transfusion-transmitted babesiosis (TTB) infection in the United States over the last 30 years. Measures to mitigate the risk of TTB include nucleic acid testing (NAT) and B. microti antibody testing. A fully automated prototype B. microti antibody test was developed on the ARCHITECT instrument. The specificity was determined to be 99.98% in volunteer blood donors (n=28,740) from areas considered as low endemic for B. microti The sensitivity of the prototype test was studied in experimentally-infected macaques; a total of 128 samples were detected compared to 125 with the indirect fluorescent antibody test (IFA), additionally, 83 (89.2%) of the PCR positive samples were detected compared to 81 (87.1%) using the IFA test. All PCR positive samples that tested negative in the prototype antibody test were pre-seroconversion period samples. Following seroconversion, periods of intermittent parasitemia occurred; 17 PCR negative samples drawn in-between PCR positive bleed dates, tested positive both by the prototype test (robust reactivity) and IFA (marginal reactivity) prior to the administration of therapeutic drugs, indicating that the PCR test failed to detect samples from persistently infected macaques. The prototype assay detected 56 of 58 (96.6%) human subjects diagnosed with clinical babesiosis by both PCR and IFA testing. Overall, the prototype anti-babesia assay provides a highly sensitive and specific test for the diagnosis of B. microti infection. While PCR is preferred for detection of window period parasitemia, antibody tests detect infected subjects during periods of low level parasitemia. Copyright © 2018 Cheng et al.
Laborde, Juan M; Sguazza, Guillermo H; Fuentealba, Nadia A; Corva, Santiago G; Carbone, Cecilia; Galosi, Cecilia M
In this study we developed an indirect ELISA to detect antibodies against Minute Virus of Mice (MVM) using an antigen produced from BHK-21 cells infected with a prototype strain of the virus. The optimal antigen concentration and serum dilutions were established. In order to analyze variability in the laboratory, reproducibility and repeatability within and between plates were determined. Then, a panel of 460 sera from conventional facilities and previously classified as positive or negative by the indirect fluorescent antibody assay was analyzed. The cutoff value was determined by a receiver operating characteristic (ROC) curve. The results of the indirect ELISA were compared with those of the indirect fluorescent antibody assay. The ELISA assay showed 100% sensitivity and 99% specificity. ELISA is a useful tool to be developed in standard virology laboratories and can be used for screening animals faster than the traditional indirect fluorescent antibody assay. Copyright © 2017 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.
[A new method of fabricating photoelastic model by rapid prototyping].
Fan, Li; Huang, Qing-feng; Zhang, Fu-qiang; Xia, Yin-pei
2011-10-01
To explore a novel method of fabricating the photoelastic model using rapid prototyping technique. A mandible model was made by rapid prototyping with computerized three-dimensional reconstruction, then the photoelastic model with teeth was fabricated by traditional impression duplicating and mould casting. The photoelastic model of mandible with teeth, which was fabricated indirectly by rapid prototyping, was very similar to the prototype in geometry and physical parameters. The model was of high optical sensibility and met the experimental requirements. Photoelastic model of mandible with teeth indirectly fabricated by rapid prototyping meets the photoelastic experimental requirements well.
Chen, Qi; Thomas, Joseph T; Giménez-Lirola, Luis G; Hardham, John M; Gao, Qinshan; Gerber, Priscilla F; Opriessnig, Tanja; Zheng, Ying; Li, Ganwu; Gauger, Phillip C; Madson, Darin M; Magstadt, Drew R; Zhang, Jianqiang
2016-04-05
At least two genetically different porcine epidemic diarrhea virus (PEDV) strains have been identified in the United States (U.S. PEDV prototype and S-INDEL-variant strains). The current serological assays offered at veterinary diagnostic laboratories for detection of PEDV-specific antibody are based on the U.S. PEDV prototype strain. The objectives of this study were: 1) isolate the U.S. PEDV S-INDEL-variant strain in cell culture; 2) generate antisera against the U.S. PEDV prototype and S-INDEL-variant strains by experimentally infecting weaned pigs; 3) determine if the various PEDV serological assays could detect antibodies against the U.S. PEDV S-INDEL-variant strain and vice versa. A U.S. PEDV S-INDEL-variant strain was isolated in cell culture in this study. Three groups of PEDV-negative, 3-week-old pigs (five pigs per group) were inoculated orally with a U.S. PEDV prototype isolate (previously isolated in our lab), an S-INDEL-variant isolate or virus-negative culture medium. Serum samples collected at 0, 7, 14, 21 and 28 days post inoculation were evaluated by the following PEDV serological assays: 1) indirect fluorescent antibody (IFA) assays using the prototype and S-INDEL-variant strains as indicator viruses; 2) virus neutralization (VN) tests against the prototype and S-INDEL-variant viruses; 3) PEDV prototype strain whole virus based ELISA; 4) PEDV prototype strain S1-based ELISA; and 5) PEDV S-INDEL-variant strain S1-based ELISA. The positive antisera against the prototype strain reacted to and neutralized both prototype and S-INDEL-variant viruses, and the positive antisera against the S-INDEL-variant strain also reacted to and neutralized both prototype and S-INDEL-variant viruses, as examined by IFA antibody assays and VN tests. Antibodies against the two PEDV strains could be detected by all three ELISAs although detection rates varied to some degree. These data indicate that the antibodies against U.S. PEDV prototype and S-INDEL-variant strains cross-reacted and cross-neutralized both strains in vitro. The current serological assays based on U.S. PEDV prototype strain can detect antibodies against both U.S. PEDV strains.
Tritium power source for long-lived sensors
NASA Astrophysics Data System (ADS)
Litz, M. S.; Katsis, D. C.; Russo, J. A.; Carroll, J. J.
2014-06-01
A tritium-based indirect converting photovoltaic (PV) power source has been designed and prototyped as a long-lived (~15 years) power source for sensor networks. Tritium is a biologically benign beta emitter and low-cost isotope acquired from commercial vendors for this purpose. The power source combines tritium encapsulated with a radioluminescent phosphor coupled to a commercial PV cell. The tritium, phosphor, and PV components are packaged inside a BA5590-style military-model enclosure. The package has been approved by the nuclear regulatory commission (NRC) for use by DOD. The power source is designed to produce 100μW electrical power for an unattended radiation sensor (scintillator and avalanche photodiode) that can detect a 20 μCi source of 137Cs at three meters. This beta emitting indirect photon conversion design is presented as step towards the development of practical, logistically acceptable, lowcost long-lived compact power sources for unattended sensor applications in battlefield awareness and environmental detection.
Development of a flight software testing methodology
NASA Technical Reports Server (NTRS)
Mccluskey, E. J.; Andrews, D. M.
1985-01-01
The research to develop a testing methodology for flight software is described. An experiment was conducted in using assertions to dynamically test digital flight control software. The experiment showed that 87% of typical errors introduced into the program would be detected by assertions. Detailed analysis of the test data showed that the number of assertions needed to detect those errors could be reduced to a minimal set. The analysis also revealed that the most effective assertions tested program parameters that provided greater indirect (collateral) testing of other parameters. In addition, a prototype watchdog task system was built to evaluate the effectiveness of executing assertions in parallel by using the multitasking features of Ada.
Ren, Kuan; Liu, Shenye; Du, Huabing; Hou, Lifei; Jing, Longfei; Zhao, Yang; Yang, Zhiwen; Wei, Minxi; Deng, Keli; Yao, Li; Yang, Guohong; Li, Sanwei; Lan, Ke; Liu, Jie; Zhu, Xiaoli; Ding, Yongkun; Yi, Lin
2015-10-01
The space-resolving measurement of X-ray flux from a specific area (laser spot, re-emitting wall, or capsule) inside the hohlraum is an ongoing and critical problem in indirectly driven inertial-confinement fusion experiments. In this work, we developed a new two-dimensional space-resolving flux detection technique to measure the X-ray flux from specific areas inside the hohlraum by using the time- and space-resolving flux detector (SRFD). In two typical hohlraum experiments conducted at the Shenguang-III prototype laser facility, the X-ray flux and radiation temperature from an area 0.2 mm in diameter inside the hohlraum were measured through the laser entrance hole (LEH). The different flux intensities and radiation temperatures detected using the SRFD from the inner area of the LEH were compared with the result measured using the flat-response X-ray detector from the entire LEH. This comparison was also analyzed theoretically. The inner area detected using the SRFD was found to be the re-emitting wall area alone. This important improvement in space-resolving X-ray flux measurement will enhance the current X-ray flux space characterization techniques, thereby furthering the quantitative understanding of X-ray flux space behavior in the hohlraum.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ren, Kuan; Research Center of Laser Fusion, China Academy of Engineering Physics, P.O. Box 919-986, Mianyang 621900; Liu, Shenye, E-mail: lsye1029@163.com
2015-10-15
The space-resolving measurement of X-ray flux from a specific area (laser spot, re-emitting wall, or capsule) inside the hohlraum is an ongoing and critical problem in indirectly driven inertial-confinement fusion experiments. In this work, we developed a new two-dimensional space-resolving flux detection technique to measure the X-ray flux from specific areas inside the hohlraum by using the time- and space-resolving flux detector (SRFD). In two typical hohlraum experiments conducted at the Shenguang-III prototype laser facility, the X-ray flux and radiation temperature from an area 0.2 mm in diameter inside the hohlraum were measured through the laser entrance hole (LEH). Themore » different flux intensities and radiation temperatures detected using the SRFD from the inner area of the LEH were compared with the result measured using the flat-response X-ray detector from the entire LEH. This comparison was also analyzed theoretically. The inner area detected using the SRFD was found to be the re-emitting wall area alone. This important improvement in space-resolving X-ray flux measurement will enhance the current X-ray flux space characterization techniques, thereby furthering the quantitative understanding of X-ray flux space behavior in the hohlraum.« less
Sawant, Amit; Antonuk, Larry E; El-Mohri, Youcef; Zhao, Qihua; Wang, Yi; Li, Yixin; Du, Hong; Perna, Louis
2006-04-01
Modern-day radiotherapy relies on highly sophisticated forms of image guidance in order to implement increasingly conformal treatment plans and achieve precise dose delivery. One of the most important goals of such image guidance is to delineate the clinical target volume from surrounding normal tissue during patient setup and dose delivery, thereby avoiding dependence on surrogates such as bony landmarks. In order to achieve this goal, it is necessary to integrate highly efficient imaging technology, capable of resolving soft-tissue contrast at very low doses, within the treatment setup. In this paper we report on the development of one such modality, which comprises a nonoptimized, prototype electronic portal imaging device (EPID) based on a 40 mm thick, segmented crystalline CsI(Tl) detector incorporated into an indirect-detection active matrix flat panel imager (AMFPI). The segmented detector consists of a matrix of 160 x 160 optically isolated, crystalline CsI(Tl) elements spaced at 1016 microm pitch. The detector was coupled to an indirect detection-based active matrix array having a pixel pitch of 508 microm, with each detector element registered to 2 x 2 array pixels. The performance of the prototype imager was evaluated under very low-dose radiotherapy conditions and compared to that of a conventional megavoltage AMFPI based on a Lanex Fast-B phosphor screen. Detailed quantitative measurements were performed in order to determine the x-ray sensitivity, modulation transfer function, noise power spectrum, and detective quantum efficiency (DQE). In addition, images of a contrast-detail phantom and an anthropomorphic head phantom were also acquired. The prototype imager exhibited approximately 22 times higher zero-frequency DQE (approximately 22%) compared to that of the conventional AMFPI (approximately 1%). The measured zero-frequency DQE was found to be lower than theoretical upper limits (approximately 27%) calculated from Monte Carlo simulations, which were based solely on the x-ray energy absorbed in the detector-indicating the presence of optical Swank noise. Moreover, due to the nonoptimized nature of this prototype, the spatial resolution was observed to be significantly lower than theoretical expectations. Nevertheless, due to its high quantum efficiency (approximately 55%), the prototype imager exhibited significantly higher DQE than that of the conventional AMFPI across all spatial frequencies. In addition, the frequency-dependent DQE was observed to be relatively invariant with respect to the amount of incident radiation, indicating x-ray quantum limited behavior. Images of the contrast-detail phantom and the head phantom obtained using the prototype system exhibit good visualization of relatively large, low-contrast features, and appear significantly less noisy compared to similar images from a conventional AMFPI. Finally, Monte Carlo-based theoretical calculations indicate that, with proper optimization, further, significant improvements in the DQE performance of such imagers could be achieved. It is strongly anticipated that the realization of optimized versions of such very high-DQE EPIDs would enable megavoltage projection imaging at very low doses, and tomographic imaging from a "beam's eye view" at clinically acceptable doses.
Antideuteron based dark matter search with GAPS: Current progress and future prospects
NASA Astrophysics Data System (ADS)
Hailey, C. J.; Aramaki, T.; Boggs, S. E.; Doetinchem, P. v.; Fuke, H.; Gahbauer, F.; Koglin, J. E.; Madden, N.; Mognet, S. A. I.; Ong, R.; Yoshida, T.; Zhang, T.; Zweerink, J. A.
2013-01-01
The General Antiparticle Spectrometer (GAPS) is a new approach to the indirect detection of dark matter. It relies on searching for primary antideuterons produced in the annihilation of dark matter in the galactic halo. Low energy antideuterons produced through Standard Model processes, such as collisions of cosmic-rays with interstellar baryons, are greatly suppressed compared to primary antideuterons. Thus a low energy antideuteron search provides a clean signature of dark matter. In GAPS antiparticles are slowed down and captured in target atoms. The resultant exotic atom deexcites with the emission of X-rays and annihilation pions, protons and other particles. A tracking geometry allows for the detection of the X-rays and particles, providing a unique signature to identify the mass of the antiparticle. A prototype detector was successfully tested at the KEK accelerator in 2005, and a prototype GAPS balloon flight is scheduled for 2011. This will be followed by a full scale experiment on a long duration balloon from Antarctica in 2014. We discuss the status and future plans for GAPS.
NASA Technical Reports Server (NTRS)
Mullican, R. C.; Hayes, B. C.
1991-01-01
Preliminary results of research conducted in the late 1970's indicate that perceptual qualities of an enclosure can be influenced by the distribution of illumination within the enclosure. Subjective impressions such as spaciousness, perceptual clarity, and relaxation or tenseness, among others, appear to be related to different combinations of surface luminance. A prototype indirect ambient illumination system was developed which will allow crew members to alter surface luminance distributions within an enclosed module, thus modifying perceptual cues to match crew preferences. A traditional lensed direct lighting system was compared to the prototype utilizing the full-scale mockup of Space Station Freedom developed by Marshall Space Flight Center. The direct lensed system was installed in the habitation module with the indirect prototype deployed in the U.S. laboratory module. Analysis centered on the illuminance and luminance distributions resultant from these systems and the implications of various luminaire spacing options. All test configurations were evaluated for compliance with NASA Standard 3000, Man-System Integration Standards.
Prototype of sun projector device
NASA Astrophysics Data System (ADS)
Ihsan; Dermawan, B.
2016-11-01
One way to introduce astronomy to public, including students, can be handled by solar observation. The widely held device for this purpose is coelostat and heliostat. Besides using filter attached to a device such as telescope, it is safest to use indirect way for observing the Sun. The main principle of the indirect way is deflecting the sun light and projecting image of the sun on a screen. We design and build a simple and low-cost astronomical device, serving as a supplement to increase public service, especially for solar observation. Without using any digital and intricate supporting equipment, people can watch and relish image of the Sun in comfortable condition, i.e. in a sheltered or shady place. Here we describe a design and features of our prototype of the device, which still, of course, has some limitations. In the future, this prototype can be improved for more efficient and useful applications.
Elliott, Timothy R; Hsiao, Yu-Yu; Kimbrel, Nathan A; Meyer, Eric C; DeBeer, Bryann B; Gulliver, Suzy Bird; Kwok, Oi-Man; Morissette, Sandra B
2015-08-01
We examined the prospective influence of the resilient, undercontrolled, and overcontrolled personality prototypes on depression and posttraumatic stress disorder (PTSD) symptoms among Iraq/Afghanistan war veterans. After accounting for the possible influence of combat exposure, we expected that the resilient prototype would predict lower depression and PTSD over time and would be associated with adaptive coping strategies, higher social support, lower psychological inflexibility, and higher self-reported resilience relative to overcontrolled and undercontrolled prototypes, independent of traumatic brain injury (TBI) status. One hundred twenty-seven veterans (107 men, 20 women; average age = 37) participated in the study. Personality was assessed at baseline, and PTSD and depression symptoms were assessed 8 months later. Path analysis was used to test the direct and indirect effects of personality on distress. No direct effects were observed from personality to distress. The resilient prototype did have significant indirect effects on PTSD and depression through its beneficial effects on social support, coping and psychological inflexibility. TBI also had direct effects on PTSD. A resilient personality prototype appears to influence veteran adjustment through its positive associations with greater social support and psychological flexibility, and lower use of avoidant coping. Low social support, avoidant coping, and psychological inflexibility are related to overcontrolled and undercontrolled personality prototypes, and these behaviors seem to characterize veterans who experience problems with depression and PTSD over time. A positive TBI status is directly and prospectively associated with PTSD symptomology independent of personality prototype. Implications for clinical interventions and future research are discussed. (c) 2015 APA, all rights reserved).
10 CFR 32.103 - Schedule D-prototype tests for ice detection devices containing strontium-90.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Schedule D-prototype tests for ice detection devices... § 32.103 Schedule D—prototype tests for ice detection devices containing strontium-90. An applicant for a license pursuant to § 32.61 shall conduct prototype tests on each of five prototype ice detection...
10 CFR 32.103 - Schedule D-prototype tests for ice detection devices containing strontium-90.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Schedule D-prototype tests for ice detection devices... § 32.103 Schedule D—prototype tests for ice detection devices containing strontium-90. An applicant for a license pursuant to § 32.61 shall conduct prototype tests on each of five prototype ice detection...
10 CFR 32.103 - Schedule D-prototype tests for ice detection devices containing strontium-90.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Schedule D-prototype tests for ice detection devices... § 32.103 Schedule D—prototype tests for ice detection devices containing strontium-90. An applicant for a license pursuant to § 32.61 shall conduct prototype tests on each of five prototype ice detection...
The High Energy cosmic-Radiation Detection (HERD) Facility onboard China's Future Space Station
NASA Astrophysics Data System (ADS)
Wu, Bobing
2015-08-01
The High Energy cosmic-Radiation Detection (HERD) facility is one of several space astronomy payloads of the cosmic lighthouse program onboard China's Space Station, which is planned for operation starting around 2020 for about 10 years. The main scientific objectives of HERD are indirect dark matter search, precise cosmic ray spectrum and composition measurements up to the knee energy, and high energy gamma-ray monitoring and survey. HERD is composed of a 3-D cubic calorimeter (CALO) surrounded by microstrip silicon trackers (STKs)from five sides except the bottom. CALO is made of about 10^4 cubes of LYSO crystals, corresponding to about 55 radiation lengths and 3 nuclear interaction lengths, respectively. HERD can achieve the following performance: energy resolution of 1% for electrons and gamma-rays beyond 100 GeV, 20% for protons from 100 GeV to 1 PeV; 2) electron/proton separation power better than 10^5 ; effective geometrical factors of > 3 m^2 sr for electron and diffuse gamma-rays, > 2 m^2 sr for cosmic ray nuclei. The prototype of about 1/40 of HERD calorimeter is under construction. A beam test in CERN with the prototype is approved and will be carried out in Nov. 2015.
Zhang, Lijun; Zunger, Alex
2015-02-11
Layered group-VIB transition metal dichalcogenides (with the formula of MX2) are known to show a transition from an indirect band gap in the thick n-monolayer stack (MX2)n to a direct band gap at the n = 1 monolayer limit, thus converting the system into an optically active material suitable for a variety of optoelectronic applications. The origin of this transition has been attributed predominantly to quantum confinement effect at reduced n. Our analysis of the evolution of band-edge energies and wave functions as a function of n using ab initio density functional calculations including the long-range dispersion interaction reveals (i) the indirect-to-direct band gap transformation is triggered not only by (kinetic-energy controlled) quantum confinement but also by (potential-energy controlled) band repulsion and localization. On its own, neither of the two effects can explain by itself the energy evolution of the band-edge states relevant to the transformation; (ii) when n decreased, there emerge distinct regimes with characteristic localization prototypes of band-edge states deciding the optical response of the system. They are distinguished by the real-space direct/indirect in combination with momentum-space direct/indirect nature of electron and hole states and give rise to distinct types of charge distribution of the photoexcited carriers that control excitonic behaviors; (iii) the various regimes associated with different localization prototypes are predicted to change with modification of cations and anions in the complete MX2 (M = Cr, Mo, W and X = S, Se, Te) series. These results offer new insight into understanding the excitonic properties (e.g., binding energy, lifetime etc.) of multiple layered MX2 and their heterostructures.
A Biologically Inspired Cooperative Multi-Robot Control Architecture
NASA Technical Reports Server (NTRS)
Howsman, Tom; Craft, Mike; ONeil, Daniel; Howell, Joe T. (Technical Monitor)
2002-01-01
A prototype cooperative multi-robot control architecture suitable for the eventual construction of large space structures has been developed. In nature, there are numerous examples of complex architectures constructed by relatively simple insects, such as termites and wasps, which cooperatively assemble their nests. The prototype control architecture emulates this biological model. Actions of each of the autonomous robotic construction agents are only indirectly coordinated, thus mimicking the distributed construction processes of various social insects. The robotic construction agents perform their primary duties stigmergically i.e., without direct inter-agent communication and without a preprogrammed global blueprint of the final design. Communication and coordination between individual agents occurs indirectly through the sensed modifications that each agent makes to the structure. The global stigmergic building algorithm prototyped during the initial research assumes that the robotic builders only perceive the current state of the structure under construction. Simulation studies have established that an idealized form of the proposed architecture was indeed capable of producing representative large space structures with autonomous robots. This paper will explore the construction simulations in order to illustrate the multi-robot control architecture.
Cleveland, Michael J; Turrisi, Rob; Gibbons, Frederick X; Gerrard, Meg; Marzell, Miesha
2018-06-07
We examined how mothers' protective parenting and alcohol use influenced changes in offspring's heavy drinking among a sample of African American youth. The conceptual model also tested indirect effects of mothers' behaviors, through changes in the youths' social images (i.e., prototypes) of heavy drinkers, derived from the prototype willingness (PW) model. Participants were 686 emerging adults (55% female) from the Family and Community Health Study (FACHS), an ongoing prospective study of African American families. Three waves of FACHS data were used as follows: T3 during 10th grade (M age = 16.3 years), T4 shortly after high school (M age = 19.4 years), and T5 3 years later (M age = 22.1 years). Mothers' self-reports of protective parenting and alcohol use were assessed at T4. Two separate path models tested the study hypotheses. The first model specified direct and indirect effects of mothers' protective parenting and alcohol use. The second model added interaction terms between the protective parenting behaviors and mothers' alcohol use. The analyses were first conducted using the full sample and then repeated separately for female and male participants. Maternal alcohol use had a positive and direct effect on offspring's alcohol use. Mothers' endorsement of alcohol-related rules inhibited normative increases in the favorability of the offspring's social image of heavy drinkers (prototype) while her warmth was positively related to these increases. Maternal alcohol use amplified the positive association between mothers' warmth and the daughters' increased drinking. For sons, maternal alcohol use increased the positive association between alcohol-related rules and increased prototype favorability. Results indicated clear gender differences in how mothers' behaviors influence her offspring's alcohol use during the transition to emerging adulthood. Interventions that target culturally specific risk and protective factors within the family environment are needed to reduce health disparities among this vulnerable population of youth. Copyright © 2018 by the Research Society on Alcoholism.
Portable Neutron Sensors for Emergency Response Operations
DOE Office of Scientific and Technical Information (OSTI.GOV)
,
2012-06-24
This article presents the experimental work performed in the area of neutron detector development at the Remote Sensing Laboratory–Andrews Operations (RSL-AO) sponsored by the U.S. Department of Energy, National Nuclear Security Administration (NNSA) in the last four years. During the 1950s neutron detectors were developed mostly to characterize nuclear reactors where the neutron flux is high. Due to the indirect nature of neutron detection via interaction with other particles, neutron counting and neutron energy measurements have never been as precise as gamma-ray counting measurements and gamma-ray spectroscopy. This indirect nature is intrinsic to all neutron measurement endeavors (except perhaps formore » neutron spin-related experiments, viz. neutron spin-echo measurements where one obtains μeV energy resolution). In emergency response situations generally the count rates are low, and neutrons may be scattered around in inhomogeneous intervening materials. It is also true that neutron sensors are most efficient for the lowest energy neutrons, so it is not as easy to detect and count energetic neutrons. Most of the emergency response neutron detectors are offshoots of nuclear device diagnostics tools and special nuclear materials characterization equipment, because that is what is available commercially. These instruments mostly are laboratory equipment, and not field-deployable gear suited for mobile teams. Our goal is to design and prototype field-deployable, ruggedized, lightweight, efficient neutron detectors.« less
Dark matter direct detection of a fermionic singlet at one loop
NASA Astrophysics Data System (ADS)
Herrero-García, Juan; Molinaro, Emiliano; Schmidt, Michael A.
2018-06-01
The strong direct detection limits could be pointing to dark matter - nucleus scattering at loop level. We study in detail the prototype example of an electroweak singlet (Dirac or Majorana) dark matter fermion coupled to an extended dark sector, which is composed of a new fermion and a new scalar. Given the strong limits on colored particles from direct and indirect searches we assume that the fields of the new dark sector are color singlets. We outline the possible simplified models, including the well-motivated cases in which the extra scalar or fermion is a Standard Model particle, as well as the possible connection to neutrino masses. We compute the contributions to direct detection from the photon, the Z and the Higgs penguins for arbitrary quantum numbers of the dark sector. Furthermore, we derive compact expressions in certain limits, i.e., when all new particles are heavier than the dark matter mass and when the fermion running in the loop is light, like a Standard Model lepton. We study in detail the predicted direct detection rate and how current and future direct detection limits constrain the model parameters. In case dark matter couples directly to Standard Model leptons we find an interesting interplay between lepton flavor violation, direct detection and the observed relic abundance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Dongxiao; Shan, Lianqiang; Zhou, Weimin
During fast-ignition implosions, preheating of inside the cone tip caused by hard X-rays can strongly affect the generation and transport of hot electrons in the cone. Although indirect-drive implosions have a higher implosion symmetry, they cause stronger preheating effects than direct-drive implosions. To control the preheating of the cone tip, we propose the use of indirect-drive fast-ignition targets with thicker tips. Experiments carried out at the ShenGuang-III prototype laser facility confirmed that thicker tips are effective for controlling preheating. Moreover, these results were consistent with those of 1D radiation hydrodynamic simulations.
An acoustic sensor for monitoring airflow in pediatric tracheostomy patients.
Ruscher, Thomas; Wicks Phd, Alexandrina; Muelenaer Md, Andre
2012-01-01
Without proper monitoring, patients with artificial airways in the trachea are at high risk for complications or death. Despite routine maintenance of the tube, dislodged or copious mucus can obstruct the airway. Young children ( 3yrs) have difficulty tending to their own tubes and are particularly vulnerable to blockages. They require external respiratory sensors. In a hospital environment, ventilators, end-tidal CO2 monitors, thermistors, and other auxiliary equipment provide sufficient monitoring of respiration. However, outpatient monitoring methods, such as thoracic impedance and pulse oximetry, are indirect and prone to false positives. Desensitization of caregivers to frequent false alarms has been cited in medical literature as a contributing factor in cases of child death. Ultrasonic time-of-flight (TOF) is a technique used in specialized industrial applications to non-invasively measure liquid and gas flow. Two transducers are oriented at a diagonal across a flow channel. Velocity measurement is accomplished by detecting slight variations in transit time of contra-propagating acoustic signals with a directional component parallel to air flow. Due to the symmetry of acoustic pathway between sensors, velocity measurements are immune to partial fouling in the tube from mucus, saliva, and condensation. A first generation proof of concept prototype was constructed to evaluate the ultrasonic TOF technique for medical tracheostomy monitoring. After successful performance, a second generation prototype was designed with a smaller form factor and more advanced electronics. This prototype was tested and found to measure inspired volume with a root-mean-square error < 2% during initial trials.
van Lettow, Britt; de Vries, Hein; Burdorf, Alex; van Empelen, Pepijn
2016-01-01
Prototypes (i.e., social images representing perceptions of typical persons engaging in or refraining from certain behaviour) have been shown to explain health-related behaviours. The present meta-analysis quantified the strength of the associations of prototype perceptions with health motivation and behaviour. Specifically, the analysis addressed (i) the relationship of prototype favourability (i.e., degree of likability) and similarity (i.e., perceived resemblance to the self) with behaviour, willingness and intentions; (ii) the effect of the interaction between favourability and similarity; and (iii) the extent to which health-risk and health-protective prototypes differed in their association with these outcomes. A total of 80 independent studies were identified based on 69 articles. The results indicated that prototype favourability and similarity were related to behaviour, intentions and willingness with small-to-medium effect sizes (r+ = 0.12-0.43). Direct measures of prototype perceptions generally produced larger effects than indirect measures. The interaction between favourability and similarity produced small-to-large effect sizes (r+ = .22-.54). The results suggest that both health-risk and health-protective prototypes might be useful targets for interventions (r+ = .22-.54). In order to increase health-protective behaviours, intentions and behaviour could be targeted by increasing similarity to health-protective prototypes. Health-risk behaviour might be decreased by targeting willingness by modifying health-risk prototype favourability and similarity.
Prototype Willingness Model Drinking Cognitions Mediate Personalized Normative Feedback Efficacy.
Lewis, Melissa A; Litt, Dana M; Tomkins, Mary; Neighbors, Clayton
2017-05-01
Personalized normative feedback (PNF) interventions have been shown to be efficacious at reducing college student drinking. Because descriptive norms have been shown to mediate PNF efficacy, the current study focused on examining additional prototype willingness model social reaction cognitions, namely, prototypes and willingness, as mediators of intervention efficacy. We expected the PNF interventions to be associated with increased prototype favorability of students who do not drink, which would in turn be associated with decreased willingness to drink and subsequently, less drinking. The current study included 622 college students (53.2% women; 62% Caucasian) who reported one or more heavy drinking episodes in the past month and completed baseline and three-month follow-up assessments. As posited by the framework of the prototype willingness model, sequential mediation analyses were conducted to evaluate increases in abstainer prototype favorability on willingness on drinking, and subsequently willingness to drink on drinking behavior. Mediation results revealed significant indirect effects of PNF on three-month drinking through three-month prototypes and willingness, indicating that the social reaction pathway of the prototype willingness model was supported. Findings have important implications for PNF interventions aiming to reduce high-risk drinking among college students. Study findings suggest that we should consider looking at additional socially-based mediators of PNF efficacy in addition to perceived descriptive norms.
Prototype Willingness Model Drinking Cognitions Mediate Personalized Normative Feedback Efficacy
Litt, Dana M.; Tomkins, Mary; Neighbors, Clayton
2017-01-01
Personalized normative feedback (PNF) interventions have been shown to be efficacious at reducing college student drinking. Because descriptive norms have been shown to mediate PNF efficacy, the current study focused on examining additional prototype willingness model social reaction cognitions, namely, prototypes and willingness, as mediators of intervention efficacy. We expected the PNF interventions to be associated with increased prototype favorability of students who do not drink, which would in turn be associated with decreased willingness to drink and subsequently, less drinking. The current study included 622 college students (53.2% women; 62% Caucasian) who reported one or more heavy drinking episodes in the past month and completed baseline and three-month follow-up assessments. As posited by the framework of the prototype willingness model, sequential mediation analyses were conducted to evaluate increases in abstainer prototype favorability on willingness on drinking, and subsequently willingness to drink on drinking behavior. Mediation results revealed significant indirect effects of PNF on three-month drinking through three-month prototypes and willingness, indicating that the social reaction pathway of the prototype willingness model was supported. Findings have important implications for PNF interventions aiming to reduce high-risk drinking among college students. Study findings suggest that we should consider looking at additional socially-based mediators of PNF efficacy in addition to perceived descriptive norms. PMID:27995431
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heady, R.; Luger, G.F.; Maccabe, A.B.
1991-05-15
This paper presents the implementation of a prototype network level intrusion detection system. The prototype system monitors base level information in network packets (source, destination, packet size, time, and network protocol), learning the normal patterns and announcing anomalies as they occur. The goal of this research is to determine the applicability of current intrusion detection technology to the detection of network level intrusions. In particular, the authors are investigating the possibility of using this technology to detect and react to worm programs.
A Multiple Sensor Machine Vision System for Automatic Hardwood Feature Detection
D. Earl Kline; Richard W. Conners; Daniel L. Schmoldt; Philip A. Araman; Robert L. Brisbin
1993-01-01
A multiple sensor machine vision prototype is being developed to scan full size hardwood lumber at industrial speeds for automatically detecting features such as knots holes, wane, stain, splits, checks, and color. The prototype integrates a multiple sensor imaging system, a materials handling system, a computer system, and application software. The prototype provides...
Schaefgen, Benedikt; Heil, Joerg; Barr, Richard G; Radicke, Marcus; Harcos, Aba; Gomez, Christina; Stieber, Anne; Hennigs, André; von Au, Alexandra; Spratte, Julia; Rauch, Geraldine; Rom, Joachim; Schütz, Florian; Sohn, Christof; Golatta, Michael
2018-06-01
To determine the feasibility of a prototype device combining 3D-automated breast ultrasound (ABVS) and digital breast tomosynthesis in a single device to detect and characterize breast lesions. In this prospective feasibility study, the FUSION-X-US prototype was used to perform digital breast tomosynthesis and ABVS in 23 patients with an indication for tomosynthesis based on current guidelines after clinical examination and standard imaging. The ABVS and tomosynthesis images of the prototype were interpreted separately by two blinded experts. The study compares the detection and BI-RADS® scores of breast lesions using only the tomosynthesis and ABVS data from the FUSION-X-US prototype to the results of the complete diagnostic workup. Image acquisition and processing by the prototype was fast and accurate, with some limitations in ultrasound coverage and image quality. In the diagnostic workup, 29 solid lesions (23 benign, including three cases with microcalcifications, and six malignant lesions) were identified. Using the prototype, all malignant lesions were detected and classified as malignant or suspicious by both investigators. Solid breast lesions can be localized accurately and fast by the Fusion-X-US system. Technical improvements of the ultrasound image quality and ultrasound coverage are needed to further study this new device. The prototype combines tomosynthesis and automated 3D-ultrasound (ABVS) in one device. It allows accurate detection of malignant lesions, directly correlating tomosynthesis and ABVS data. The diagnostic evaluation of the prototype-acquired data was interpreter-independent. The prototype provides a time-efficient and technically reliable diagnostic procedure. The combination of tomosynthesis and ABVS is a promising diagnostic approach.
NASA Astrophysics Data System (ADS)
Hamamoto, K.; Kaneko, Y.; Sobue, S.; Oyoshi, K.
2016-12-01
Climate change and human activities are directly or indirectly influence the acceleration of environmental problems and natural hazards such as forest fires, drought and floods in the Asia-Pacific countries. Satellite technology has become one of the key information sources in assessment, monitoring and mitigation of these hazards and related phenomenon. However, there are still gaps between science and application of space technology in practical usage. Asia-Pacific Regional Space Agency Forum (APRSAF) recommended to initiate the Space Applications for Environment (SAFE) proposal providing opportunity to potential user agencies in the Asia Pacific region to develop prototype applications of space technology for number of key issues including forest resources management, coastal monitoring and management, agriculture and food security, water resource management and development user-friendly tools for application of space technology. The main activity of SAFE is SAFE prototyping. SAFE prototyping is a demonstration for end users and decision makers to apply space technology applications for solving environmental issues in Asia-Pacific region. By utilizing space technology and getting technical support by experts, prototype executers can develop the application system, which could support decision making activities. SAFE holds a workshop once a year. In the workshop, new prototypes are approved and the progress of on-going prototypes are confirmed. Every prototype is limited for two years period and all activities are operated by volunteer manner. As of 2016, 20 prototypes are completed and 6 prototypes are on-going. Some of the completed prototypes, for example drought monitoring in Indonesia were applied to operational use by a local official organization.
Burleson, Winslow; Lozano, Cecil; Ravishankar, Vijay; Lee, Jisoo; Mahoney, Diane
2018-05-01
Individuals living with advancing stages of dementia (persons with dementia, PWDs) or other cognitive disorders do not have the luxury of remembering how to perform basic day-to-day activities, which in turn makes them increasingly dependent on the assistance of caregivers. Dressing is one of the most common and stressful activities provided by caregivers because of its complexity and privacy challenges posed during the process. In preparation for in-home trials with PWDs, the aim of this study was to develop and evaluate a prototype intelligent system, the DRESS prototype, to assess its ability to provide automated assistance with dressing that can afford independence and privacy to individual PWDs and potentially provide additional freedom to their caregivers (family members and professionals). This laboratory study evaluated the DRESS prototype's capacity to detect dressing events. These events were engaged in by 11 healthy participants simulating common correct and incorrect dressing scenarios. The events ranged from donning a shirt and pants inside out or backwards to partial dressing-typical issues that challenge a PWD and their caregivers. A set of expected detections for correct dressing was prepared via video analysis of all participants' dressing behaviors. In the initial phases of donning either shirts or pants, the DRESS prototype missed only 4 out of 388 expected detections. The prototype's ability to recognize other missing detections varied across conditions. There were also some unexpected detections such as detection of the inside of a shirt as it was being put on. Throughout the study, detection of dressing events was adversely affected by the relatively smaller effective size of the markers at greater distances. Although the DRESS prototype incorrectly identified 10 of 22 cases for shirts, the prototype preformed significantly better for pants, incorrectly identifying only 5 of 22 cases. Further analyses identified opportunities to improve the DRESS prototype's reliability, including increasing the size of markers, minimizing garment folding or occlusions, and optimal positioning of participants with respect to the DRESS prototype. This study demonstrates the ability to detect clothing orientation and position and infer current state of dressing using a combination of sensors, intelligent software, and barcode tracking. With improvements identified by this study, the DRESS prototype has the potential to provide a viable option to provide automated dressing support to assist PWDs in maintaining their independence and privacy, while potentially providing their caregivers with the much-needed respite. ©Winslow Burleson, Cecil Lozano, Vijay Ravishankar, Jisoo Lee, Diane Mahoney. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 01.05.2018.
A Stigmergic Cooperative Multi-Robot Control Architecture
NASA Technical Reports Server (NTRS)
Howsman, Thomas G.; O'Neil, Daniel; Craft, Michael A.
2004-01-01
In nature, there are numerous examples of complex architectures constructed by relatively simple insects, such as termites and wasps, which cooperatively assemble their nests. A prototype cooperative multi-robot control architecture which may be suitable for the eventual construction of large space structures has been developed which emulates this biological model. Actions of each of the autonomous robotic construction agents are only indirectly coordinated, thus mimicking the distributed construction processes of various social insects. The robotic construction agents perform their primary duties stigmergically, i.e., without direct inter-agent communication and without a preprogrammed global blueprint of the final design. Communication and coordination between individual agents occurs indirectly through the sensed modifications that each agent makes to the structure. The global stigmergic building algorithm prototyped during the initial research assumes that the robotic builders only perceive the current state of the structure under construction. Simulation studies have established that an idealized form of the proposed architecture was indeed capable of producing representative large space structures with autonomous robots. This paper will explore the construction simulations in order to illustrate the multi-robot control architecture.
An improved Abbott ARCHITECT assay for the detection of hepatitis B virus surface antigen (HBsAg).
Lou, Sheng C; Pearce, Sandra K; Lukaszewska, Teresa X; Taylor, Russell E; Williams, Gregg T; Leary, Thomas P
2011-05-01
The sensitive and accurate detection of hepatitis B virus surface antigen (HBsAg) is critical to the identification of infection and the prevention of transfusion transmitted disease. Improvement in HBsAg assay sensitivity is essential to reduce the window to detect an acute HBV infection. Additionally, the sensitive detection of HBsAg mutants that continue to evolve due to vaccine escape, immune selection and an error prone reverse transcriptase is a necessity. A fully automated HBsAg prototype assay on the Abbott ARCHITECT instrument was developed to improve sensitivity and mutant detection. This magnetic microparticle-based assay utilizes anti-HBsAg monoclonal antibodies to capture antigen present in serum or plasma. Captured antigen is then detected using anti-HBsAg antibody conjugated with the chemiluminescent compound, acridinium. The sensitivity of the ARCHITECT HBsAg prototype assay was improved as compared to the current ARCHITECT, PRISM, and competitor HBsAg assays. The enhancement in assay sensitivity was demonstrated by the use of commercially available HBV seroconversion panels. The prototype assay detected more panel members (185 of 383) vs. the current ARCHITECT (171), PRISM (181), or competitor HBsAg assays (73/140 vs. 62/140, respectively). The ARCHITECT prototype assay also efficiently detected all mutants evaluated. Finally, the sensitivity improvement did not compromise the specificity of the assay (99.94%). An improved Abbott ARCHITECT HBsAg prototype assay with enhanced detection of HBsAg and HBsAg mutants, as well as equivalent specificity was developed for the detection, diagnosis, and management of HBV infection. Copyright © 2011 Elsevier B.V. All rights reserved.
Yeung, Edward S.; Kuhr, Werner G.
1996-02-20
A means and method for capillary zone electrphoresis with laser-induced indirect fluorescence detection. A detector is positioned on the capillary tube of a capillary zone electrophoresis system. The detector includes a laser which generates a laser beam which is imposed upon a small portion of the capillary tube. Fluorescence of the elutant electromigrating through the capillary tube is indirectly detected and recorded.
Yeung, Edwards; Kuhr, Werner G.
1991-04-09
A means and method for capillary zone electrphoresis with laser-induced indirect fluorescence detection. A detector is positioned on the capillary tube of a capillary zone electrophoresis system. The detector includes a laser which generates a laser beam which is imposed upon a small portion of the capillary tube. Fluorescence of the elutant electromigrating through the capillary tube is indirectly detected and recorded.
A single-neuron tracing study of arkypallidal and prototypic neurons in healthy rats.
Fujiyama, Fumino; Nakano, Takashi; Matsuda, Wakoto; Furuta, Takahiro; Udagawa, Jun; Kaneko, Takeshi
2016-12-01
The external globus pallidus (GP) is known as a relay nucleus of the indirect pathway of the basal ganglia. Recent studies in dopamine-depleted and healthy rats indicate that the GP comprises two main types of pallidofugal neurons: the so-called "prototypic" and "arkypallidal" neurons. However, the reconstruction of complete arkypallidal neurons in healthy rats has not been reported. Here we visualized the entire axonal arborization of four single arkypallidal neurons and six single prototypic neurons in rat brain using labeling with a viral vector expressing membrane-targeted green fluorescent protein and examined the distribution of axon boutons in the target nuclei. Results revealed that not only the arkypallidal neurons but nearly all of the prototypic neurons projected to the striatum with numerous axon varicosities. Thus, the striatum is a major target nucleus for pallidal neurons. Arkypallidal and prototypic GP neurons located in the calbindin-positive and calbindin-negative regions mainly projected to the corresponding positive and negative regions in the striatum. Because the GP and striatum calbindin staining patterns reflect the topographic organization of the striatopallidal projection, the striatal neurons in the sensorimotor and associative regions constitute the reciprocal connection with the GP neurons in the corresponding regions.
The Critical Power Model as a Potential Tool for Anti-doping
Puchowicz, Michael J.; Mizelman, Eliran; Yogev, Assaf; Koehle, Michael S.; Townsend, Nathan E.; Clarke, David C.
2018-01-01
Existing doping detection strategies rely on direct and indirect biochemical measurement methods focused on detecting banned substances, their metabolites, or biomarkers related to their use. However, the goal of doping is to improve performance, and yet evidence from performance data is not considered by these strategies. The emergence of portable sensors for measuring exercise intensities and of player tracking technologies may enable the widespread collection of performance data. How these data should be used for doping detection is an open question. Herein, we review the basis by which performance models could be used for doping detection, followed by critically reviewing the potential of the critical power (CP) model as a prototypical performance model that could be used in this regard. Performance models are mathematical representations of performance data specific to the athlete. Some models feature parameters with physiological interpretations, changes to which may provide clues regarding the specific doping method. The CP model is a simple model of the power-duration curve and features two physiologically interpretable parameters, CP and W′. We argue that the CP model could be useful for doping detection mainly based on the predictable sensitivities of its parameters to ergogenic aids and other performance-enhancing interventions. However, our argument is counterbalanced by the existence of important limitations and unresolved questions that need to be addressed before the model is used for doping detection. We conclude by providing a simple worked example showing how it could be used and propose recommendations for its implementation. PMID:29928234
Status of the prototype Pulsed Photonuclear Assessment (PPA) inspection system
NASA Astrophysics Data System (ADS)
Jones, James L.; Blackburn, Brandon W.; Norman, Daren R.; Watson, Scott M.; Haskell, Kevin J.; Johnson, James T.; Hunt, Alan W.; Harmon, Frank; Moss, Calvin
2007-08-01
The Idaho National Laboratory, in collaboration with Idaho State University's Idaho Accelerator Center and the Los Alamos National Laboratory, continues to develop the Pulsed Photonuclear Assessment (PPA) technique for shielded nuclear material detection in large volume configurations, such as cargo containers. In recent years, the Department of Homeland Security has supported the development of a prototype PPA cargo inspection system. This PPA system integrates novel neutron and gamma-ray detectors for nuclear material detection along with a complementary and unique gray scale, density mapping component for significant shield material detection. This paper will present the developmental status of the prototype system, its detection performance using several INL Calibration Pallets, and planned enhancements to further increase its nuclear material detection capability.
Elastic electron scattering by ethyl vinyl ether
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khakoo, M. A.; Hong, L.; Kim, B.
2010-02-15
We report measured and calculated results for elastic scattering of low-energy electrons by ethyl vinyl ether (ethoxyethene), a prototype system for studying indirect dissociative attachment processes that may play a role in DNA damage. The integral cross section displays the expected {pi}{sup *} shape resonance. The agreement between the calculated and measured cross sections is generally good.
Indirect detection of radiation sources through direct detection of radiolysis products
Farmer, Joseph C [Tracy, CA; Fischer, Larry E [Los Gatos, CA; Felter, Thomas E [Livermore, CA
2010-04-20
A system for indirectly detecting a radiation source by directly detecting radiolytic products. The radiation source emits radiation and the radiation produces the radiolytic products. A fluid is positioned to receive the radiation from the radiation source. When the fluid is irradiated, radiolytic products are produced. By directly detecting the radiolytic products, the radiation source is detected.
Operations management system advanced automation: Fault detection isolation and recovery prototyping
NASA Technical Reports Server (NTRS)
Hanson, Matt
1990-01-01
The purpose of this project is to address the global fault detection, isolation and recovery (FDIR) requirements for Operation's Management System (OMS) automation within the Space Station Freedom program. This shall be accomplished by developing a selected FDIR prototype for the Space Station Freedom distributed processing systems. The prototype shall be based on advanced automation methodologies in addition to traditional software methods to meet the requirements for automation. A secondary objective is to expand the scope of the prototyping to encompass multiple aspects of station-wide fault management (SWFM) as discussed in OMS requirements documentation.
Detection of a Geostationary Satellite with the Navy Prototype Optical Interferometer
2010-07-01
USA 86001 USA ABSTRACT We have detected a satellite via optical interferometry for the first time , using a 16 m baseline of the Navy Prototype Optical...available at the time of our observations, resolves out structures larger than ∼ 1.5 m at the geostationary distance, while a typical size for the solar... satellite via optical interferometry for the first time , using a 16 m baseline of the Navy Prototype Optical Interferometer (NPOI) to observe the
Vásquez-Garzón, Verónica R; Rouimi, Patrick; Jouanin, Isabelle; Waeg, Georg; Zarkovic, Neven; Villa-Treviño, Saul; Guéraud, Françoise
2012-05-01
Among disruptions induced by oxidative stress, modifications of proteins, particularly irreversible carbonylation, are associated with the development of several diseases, including cardiovascular diseases, neurodegenerative diseases, and cancer. Carbonylation of proteins can occur directly or indirectly through the adduction of lipid oxidation products. In this study, three classical and easy-to-perform techniques to detect direct or indirect carbonylation of proteins were compared. A model protein apomyoglobin and a complex mixture of rat liver cytosolic proteins were exposed to cumene hydroperoxide oxidation or adduction to the lipid peroxidation product 4-hydroxynonenal in order to test direct or indirect carbonylation, respectively. The technique using a specific anti-4-hydroxynonenal-histidine adduct antibody was effective to detect in vitro modification of model apomyoglobin and cytosolic proteins by 4-hydroxynonenal but not by direct carbonylation which was achieved by techniques using biotin-coupled hydrazide or dinitrophenylhydrazine derivatization of carbonyls. Sequential use of these methods enabled the detection of both direct and indirect carbonyl modification in proteins, although constitutively biotinylated proteins were detected by biotin-hydrazide. Although rather classical and efficient, methods for carbonyl detection on proteins in oxidative stress studies may be biased by some artifactual detections and complicated by proteins multimerizations. The use of more and more specific available antibodies is recommended to complete detection of lipid peroxidation product adducts on proteins.
DOT National Transportation Integrated Search
2018-02-01
The primary objective of Phase II was to develop a prototype connected vehicle wrong-way driving detection and management system at the Texas A&M University Respect, Excellence, Leadership, Loyalty, Integrity, Selfless Service (RELLIS) campus. The pu...
Studies on manifestations of canine distemper virus infection in an urban dog population.
Blixenkrone-Møller, M; Svansson, V; Have, P; Orvell, C; Appel, M; Pedersen, I R; Dietz, H H; Henriksen, P
1993-10-01
An upsurge of canine distemper was recognized at the beginning of 1991 in the urban dog population of the Copenhagen area. The outbreak had the characteristics of a virulent morbillivirus introduction in a partly immune population, where the disease primarily was manifested in young individuals. Testing of single serum samples for the presence of canine distemper virus (CDV) IgM antibodies using an IgM ELISA confirmed current and recent CDV infections in an urban dog population, where the use of attenuated CDV vaccines was widespread. In 49 out of 66 sera from clinical cases suspected of canine distemper we detected CDV IgM antibodies, as compared to the detection of viral antigen by indirect immunofluorescence in 27 of 65 specimens of conjunctival cells. The antigenic make-up of isolates from acute and subacute clinical cases was investigated with a panel of 51 monoclonal antibodies directed against CDV and the related phocine distemper virus. The isolates exhibited an homogeneous reaction pattern and shared overall antigenic characteristics of the CDV prototype. The majority of cases were diagnosed among unvaccinated dogs and individuals with unknown or obscure vaccination record. However, severe clinical cases were also diagnosed in vaccinated individuals.
NASA Technical Reports Server (NTRS)
Ackermann, M.; Albert, A.; Anderson, B.; Baldini, L.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Bechtol, K.; Bellazzini, R.; Bissaldi, E.;
2013-01-01
The dwarf spheroidal satellite galaxies of the Milky Way are some of the most dark-matter-dominated objects known. Due to their proximity, high dark matter content, and lack of astrophysical backgrounds, dwarf spheroidal galaxies are widely considered to be among the most promising targets for the indirect detection of dark matter via gamma rays. Here we report on gamma ray observations of 25 Milky Way dwarf spheroidal satellite galaxies based on 4 years of Fermi Large Area Telescope (LAT) data. None of the dwarf galaxies are significantly detected in gamma rays, and we present gamma ray flux upper limits between 500MeV and 500 GeV. We determine the dark matter content of 18 dwarf spheroidal galaxies from stellar kinematic data and combine LAT observations of 15 dwarf galaxies to constrain the dark matter annihilation cross section. We set some of the tightest constraints to date on the annihilation of dark matter particles with masses between 2 GeV and 10TeV into prototypical standard model channels. We find these results to be robust against systematic uncertainties in the LAT instrument performance, diffuse gamma ray background modeling, and assumed dark matter density profile.
Study of image reconstruction for terahertz indirect holography with quasi-optics receiver.
Gao, Xiang; Li, Chao; Fang, Guangyou
2013-06-01
In this paper, an indirect holographic image reconstruction algorithm was studied for terahertz imaging with a quasi-optics receiver. Based on the combination of the reciprocity principle and modified quasi-optics theory, analytical expressions of the received spatial power distribution and its spectrum are obtained for the interference pattern of target wave and reference wave. These results clearly give the quantitative relationship between imaging quality and the parameters of a Gaussian beam, which provides a good criterion for terahertz quasi-optics transceivers design in terahertz off-axis holographic imagers. To validate the effectiveness of the proposed analysis method, some imaging results with a 0.3 THz prototype system are shown based on electromagnetic simulation.
An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications.
Chabinyc, M L; Chiu, D T; McDonald, J C; Stroock, A D; Christian, J F; Karger, A M; Whitesides, G M
2001-09-15
This paper describes a prototype of an integrated fluorescence detection system that uses a microavalanche photodiode (microAPD) as the photodetector for microfluidic devices fabricated in poly(dimethylsiloxane) (PDMS). The prototype device consisted of a reusable detection system and a disposable microfluidic system that was fabricated using rapid prototyping. The first step of the procedure was the fabrication of microfluidic channels in PDMS and the encapsulation of a multimode optical fiber (100-microm core diameter) in the PDMS; the tip of the fiber was placed next to the side wall of one of the channels. The optical fiber was used to couple light into the microchannel for the excitation of fluorescent analytes. The photodetector, a prototype solid-state microAPD array, was embedded in a thick slab (1 cm) of PDMS. A thin (80 microm) colored polycarbonate filter was placed on the top of the embedded microAPD to absorb scattered excitation light before it reached the detector. The microAPD was placed below the microchannel and orthogonal to the axis of the optical fiber. The close proximity (approximately 200 microm) of the microAPD to the microchannel made it unnecessary to incorporate transfer optics; the pixel size of the microAPD (30 microm) matched the dimensions of the channels (50 microm). A blue light-emitting diode was used for fluorescence excitation. The microAPD was operated in Geiger mode to detect the fluorescence. The detection limit of the prototype (approximately 25 nM) was determined by finding the minimum detectable concentration of a solution of fluorescein. The device was used to detect the separation of a mixture of proteins and small molecules by capillary electrophoresis; the separation illustrated the suitability of this integrated fluorescence detection system for bioanalytical applications.
Novo, P; Chu, V; Conde, J P
2014-07-15
The miniaturization of biosensors using microfluidics has potential in enabling the development of point-of-care devices, with the added advantages of reduced time and cost of analysis with limits-of-detection comparable to those obtained through traditional laboratory techniques. Interfacing microfluidic devices with the external world can be difficult especially in aspects involving fluid handling and the need for simple sample insertion that avoids special equipment or trained personnel. In this work we present a point-of-care prototype system by integrating capillary microfluidics with a microfabricated photodiode array and electronic instrumentation into a hand-held unit. The capillary microfluidic device is capable of autonomous and sequential fluid flow, including control of the average fluid velocity at any given point of the analysis. To demonstrate the functionality of the prototype, a model chemiluminescence ELISA was performed. The performance of the integrated optical detection in the point-of-care prototype is equal to that obtained with traditional bench-top instrumentation. The photodiode signals were acquired, displayed and processed by a simple graphical user interface using a computer connected to the microcontroller through USB. The prototype performed integrated chemiluminescence ELISA detection in about 15 min with a limit-of-detection of ≈2 nM with an antibody-antigen affinity constant of ≈2×10(7) M(-1). Copyright © 2014 Elsevier B.V. All rights reserved.
Immunological detection of Fusarium species in cornmeal.
Iyer, M S; Cousin, M A
2003-03-01
An indirect enzyme-linked immunosorbent assay (ELISA) was developed to detect Fusarium species in foods. Antibodies to proteins extracted from the mycelia of Fusarium graminearum and Fusarium moniliforme (verticillioides) were produced in New Zealand white rabbits. These antibodies detected 13 Fusarium species in addition to the producer strains. Levels of Fusarium semitectum and Fusarium tricinctum strains were below the detection threshold. The specificity of the assay was tested against 70 molds and yeasts belonging to 23 genera. One strain of Monascus species and one strain of Phoma exigua were detected; however, these two molds are not common contaminants of cereal grains or foods and should not interfere with the assay. The indirect ELISA's detection limits for F. graminearum and F. moniliforme were 0.1 and 1 microg of mold mycelium per ml of a cornmeal mixture, respectively. When spores of each mold were added individually to cornmeal mixtures (at ca. 10 spores per g) and incubated at 25 degrees C, these spores were detected by the indirect ELISA when they reached levels of 10(2) to 10(3) CFU/ml after 24 to 36 h. The indirect ELISA developed here shows promise for the detection of Fusarium species in grains or foods.
Indirect photometric detection of boron cluster anions electrophoretically separated in methanol.
Vítová, Lada; Fojt, Lukáš; Vespalec, Radim
2014-04-18
3,5-Dinitrobenzoate and picrate are light absorbing anions pertinent to indirect photometric detection of boron cluster anions in buffered methanolic background electrolytes (BGEs). Tris(hydroxymethyl)aminomethane and morpholine have been used as buffering bases, which eliminated baseline steps, and minimized the baseline noise. In methanolic BGEs, mobilities of boron cluster anions depend on both ionic constituents of the BGE buffer. This dependence can be explained by ion pair interaction of detected anions with BGE cations, which are not bonded into ion pairs with the BGE anions. The former ion pair interaction decreases sensitivity of the indirect photometric detection. Copyright © 2014 Elsevier B.V. All rights reserved.
Liu, Yong-Qiang; Yu, Hong
2017-04-01
A convenient and versatile method was developed for the separation and detection of alkaline earth metal ions by ion chromatography with indirect UV detection. The chromatographic separation of Mg 2+ , Ca 2+ , and Sr 2+ was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid as the mobile phase, in which the imidazolium ionic liquid acted as an UV-absorption reagent. The effects of imidazolium ionic liquids, detection wavelength, acids in the mobile phase, and column temperature on the retention of Mg 2+ , Ca 2+ , and Sr 2+ were investigated. The main factors influencing the separation and detection were the background UV absorption reagent and the concentration of hydrogen ion in ion chromatography with indirect UV detection. The successful separation and detection of Mg 2+ , Ca 2+ , and Sr 2+ within 14 min were achieved using the selected chromatographic conditions, and the detection limits (S/N = 3) were 0.06, 0.12, and 0.23 mg/L, respectively. A new separation and detection method of alkaline earth metal ions by ion chromatography with indirect UV detection was developed, and the application range of ionic liquids was expanded. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
End effector monitoring system: An illustrated case of operational prototyping
NASA Technical Reports Server (NTRS)
Malin, Jane T.; Land, Sherry A.; Thronesbery, Carroll
1994-01-01
Operational prototyping is introduced to help developers apply software innovations to real-world problems, to help users articulate requirements, and to help develop more usable software. Operational prototyping has been applied to an expert system development project. The expert system supports fault detection and management during grappling operations of the Space Shuttle payload bay arm. The dynamic exchanges among operational prototyping team members are illustrated in a specific prototyping session. We discuss the requirements for operational prototyping technology, types of projects for which operational prototyping is best suited and when it should be applied to those projects.
X-ray source characteristics and detection efficiencies of prototype Lixiscopes
NASA Technical Reports Server (NTRS)
Seltzer, S. M.
1978-01-01
The radioactive X-ray sources and scintillator screens used in prototype Lixiscope units are described. Some of those considerations necessary for the optimization of future Lixiscope designs are stressed as well as some semi-quantitative information on the present prototype devices.
Can indirect tests detect a known recombination event in human mtDNA?
White, Daniel James; Gemmell, Neil John
2009-07-01
Whether human mitochondrial DNA (mtDNA) recombines sufficiently to influence its evolution, evolutionary analysis, and disease etiology, remains equivocal. Overall, evidence from indirect studies of population genetic data suggests that recombination is not occurring at detectable levels. This may be explained by no, or low, recombination or, alternatively, current indirect tests may be incapable of detecting recombination in human mtDNA. To investigate the latter, we have tested whether six well-established indirect tests of recombination could detect recombination in a human mtDNA data set, in which its occurrence had been empirically confirmed. Three showed statistical evidence for recombination (r(2) vs. distance, the Homoplasy test, Neighborhood Similarity Score), and three did not (D' vs. distance, Max Chi Squared, Pairwise Homoplasy Index). Possible reasons for detection failure are discussed. Further, evidence from earlier studies suggesting a lack of recombination in mtDNA in humans is reconsidered, taking into account the appropriateness of the tests used, based on our new findings.
Ares I-X Ground Diagnostic Prototype
NASA Technical Reports Server (NTRS)
Schwabacher, Mark A.; Martin, Rodney Alexander; Waterman, Robert D.; Oostdyk, Rebecca Lynn; Ossenfort, John P.; Matthews, Bryan
2010-01-01
The automation of pre-launch diagnostics for launch vehicles offers three potential benefits: improving safety, reducing cost, and reducing launch delays. The Ares I-X Ground Diagnostic Prototype demonstrated anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage Thrust Vector Control and for the associated ground hydraulics while the vehicle was in the Vehicle Assembly Building at Kennedy Space Center (KSC) and while it was on the launch pad. The prototype combines three existing tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool from Qualtech Systems Inc. for fault isolation and diagnostics. The second tool, SHINE (Spacecraft Health Inference Engine), is a rule-based expert system that was developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification, and used the outputs of SHINE as inputs to TEAMS. The third tool, IMS (Inductive Monitoring System), is an anomaly detection tool that was developed at NASA Ames Research Center. The three tools were integrated and deployed to KSC, where they were interfaced with live data. This paper describes how the prototype performed during the period of time before the launch, including accuracy and computer resource usage. The paper concludes with some of the lessons that we learned from the experience of developing and deploying the prototype.
A critical analysis of one standard and five methods to monitor surface wetness and time-of-wetness
NASA Astrophysics Data System (ADS)
Camuffo, Dario; della Valle, Antonio; Becherini, Francesca
2018-05-01
Surface wetness is a synergistic factor to determine atmospheric corrosion, monument weathering, mould growth, sick buildings, etc. However, its detection and monitoring are neither easy nor homogeneous, for a number of factors that may affect readings. Various types of methods and sensors, either commercial or prototypes built in the lab, have been investigated and compared, i.e. the international standard ISO 9223 to evaluate corrosivity after wetness and time-of-wetness; indirect evaluation of wetness, based on the dew point calculated after the output of temperature and relative humidity sensors and direct measurements by means of capacitive wetness sensors, safety sensors, rain sensors (also known as leaf wetness sensors), infrared reflection sensors and fibre optic sensors. A comparison between the different methods is presented, specifying physical principles, forms of wetting to which they are respondent (i.e. condensation, ice melting, splashing drops, percolation and capillary rise), critical factors, use and cost.
OverView of Space Applications for Environment (SAFE) initiative
NASA Astrophysics Data System (ADS)
Hamamoto, Ko; Fukuda, Toru; Tajima, Yoshimitsu; Takeuchi, Wataru; Sobue, Shinichi; Nukui, Tomoyuki
2014-06-01
Climate change and human activities have a direc or indirect influence on the acceleration of environmental problems and natural hazards such as forest fires, draughts and floods in the Asia-Pacific countries. Satellite technology has become one of the key information sources in assessment, monitoring and mitigation of these disasters and related phenomenon. However, there are still gaps between science and application of satellite technology in real-world usage. Asia-Pacific Regional Space Agency Forum (APRSAF) recommended to initiate the Space Applications for Environment (SAFE) proposal providing opportunity to potential user agencies in the Asia Pacific region to develop prototype applications of satellite technology for number of key issues including forest resources management, coastal monitoring and management, agriculture and food security, water resource management and development user-friendly tools for application of satellite technology. This paper describes the overview of SAFE initiative and outcomes of two selected prototypes; agricultural drought monitoring in Indonesia and coastal management in Sri Lanka, as well as the current status of on-going prototypes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yinfa, Ma.
Thin-layer chromatography (TLC) is a broadly applicable separation technique. It offers many advantages over high performance liquid chromatography (HPLC), such as easily adapted for two-dimensional separation, for whole-column'' detection and for handling multiple samples, etc. However, due to its draggy development of detection techniques comparing with HPLC, TLC has not received the attention it deserves. Therefore, exploring new detection techniques is very important to the development of TLC. It is the principal of this dissertation to present a new detection method for TLC -- indirect fluorometric detection method. This detection technique is universal sensitive, nondestructive, and simple. This will bemore » described in detail from Sections 1 through Section 5. Section 1 and 3 describe the indirect fluorometric detection of anions and nonelectrolytes in TLC. In Section 2, a detection method for cations based on fluorescence quenching of ethidium bromide is presented. In Section 4, a simple and interesting TLC experiment is designed, three different fluorescence detection principles are used for the determination of caffeine, saccharin and sodium benzoate in beverages. A laser-based indirect fluorometric detection technique in TLC is developed in Section 5. Section 6 is totally different from Sections 1 through 5. An ultrasonic effect on the separation of DNA fragments in agarose gel electrophoresis is investigated. 262 refs.« less
High rejection reverse osmosis membrane for removal of N-nitrosamines and their precursors.
Fujioka, Takahiro; Ishida, Kenneth P; Shintani, Takuji; Kodamatani, Hitoshi
2017-12-12
Direct potable reuse is becoming a feasible option to cope with water shortages. It requires more stringent water quality assurance than indirect potable reuse. Thus, the development of a high-rejection reverse osmosis (RO) membrane for the removal of one of the most challenging chemicals in potable reuse - N-nitrosodimethylamine (NDMA) - ensures further system confidence in reclaimed water quality. This study aimed to achieve over 90% removal of NDMA by modifying three commercial and one prototype RO membrane using heat treatment. Application of heat treatment to a prototype membrane resulted in a record high removal of 92% (1.1-log) of NDMA. Heat treatment reduced conductivity rejection and permeability, while secondary amines, selected as N-nitrosamine precursors, were still well rejected (>98%) regardless of RO membrane type. This study also demonstrated the highly stable separation performance of the heat-treated prototype membrane under conditions of varying feed temperature and permeate flux. Fouling propensity of the prototype membrane was lower than a commercial RO membrane. This study identified a need to develop highly selective RO membranes with high permeability to ensure the feasibility of using these membranes at full scale. Copyright © 2017 Elsevier Ltd. All rights reserved.
A knowledge-based system for monitoring the electrical power system of the Hubble Space Telescope
NASA Technical Reports Server (NTRS)
Eddy, Pat
1987-01-01
The design and the prototype for the expert system for the Hubble Space Telescope's electrical power system are discussed. This prototype demonstrated the capability to use real time data from a 32k telemetry stream and to perform operational health and safety status monitoring, detect trends such as battery degradation, and detect anomalies such as solar array failures. This prototype, along with the pointing control system and data management system expert systems, forms the initial Telemetry Analysis for Lockheed Operated Spacecraft (TALOS) capability.
Development of Intelligent Spray Systems for Nursery Crop Production
USDA-ARS?s Scientific Manuscript database
Two intelligent sprayer prototypes were developed to increase pesticide application efficiency in nursery production. The first prototype was a hydraulic vertical boom system using ultrasonic sensors to detect tree size and volume for liner-sized trees and the second prototype was an air-assisted sp...
Pinne, Marija; Ponce, Elsa; Raucy, Judy L
2017-01-01
Nuclear Receptors (NRs), including PXR and CAR, are presumed to be ligand-dependent transcription factors, but ligand binding is not an absolute requirement for activation. Indeed, many compounds activate PXR and CAR by indirect mechanisms. Detecting these indirect activators of specific nuclear receptors in vitro has been difficult. As NR activation of either or both PXR and CAR can lead to drug-drug interactions and adverse drug effects, false negatives obtained with screening tools incapable of detecting indirect activators could present liabilities. The aim of this study was to establish assays that identify indirect activators of human PXR and CAR. Commercially available human PXR and CAR transactivation assays were used for analyses. We show that transactivation assays containing full-length nuclear receptors with native promoters can identify indirect activators of human CAR and PXRwhen compared to those of commercially available assays containing only the LBD of PXR and CAR. Of these two assay systems, only human PXR and CAR1 assays with full-length receptors and native promoters are capable of detecting indirect and ligand activators. With this capability, several kinase inhibitors were identified that activate PXR and CAR by indirect mechanisms. Furthermore by using both the LBD and full-length receptors, phenobarbital and midostaurin were found to be direct and indirect activators of PXR while human CAR activation by phenobarbital occurs by indirect mechanisms only. Cell based transactivation assays employing the full-length receptors and native promoters identify both direct and indirect activators of either or both human PXR and CAR. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Forsey, T; Darougar, S
1980-02-01
A rapid indirect micro-immunofluorescence test capable of detecting and differentiating type-specific antibodies to herpes simplex virus is described. The test proved highly sensitive and, in 80 patients with active herpes ocular infection, antibody was detected in 94%. No anti-herpes antibody was detected in a control group of 20 patients with adenovirus infections. Testing of animal sera prepared against herpes simplex virus types 1 and 2 and of human sera from cases of ocular and genital herpes infections showed that the test can differentiate antibodies to the infecting serotypes. Specimens of whole blood, taken by fingerprick, and eye secretions, both collected on cellulose sponges, could be tested by indirect micro-immunofluorescence. Anti-herpes IgG, IgM, and IgA can also be detected.
Liu, M J J; Chou, S M; Chua, C K; Tay, B C M; Ng, B K
2013-02-01
To date, naturally derived biomaterials are rarely used in advanced tissue engineering (TE) methods despite their superior biocompatibility. This is because these native materials, which consist mainly of proteins and polysaccharides, do not possess the ability to withstand harsh processing conditions. Unlike synthetic polymers, natural materials degrade and decompose rapidly in the presence of chemical solvents and high temperature, respectively. Thus, the fabrication of tissue scaffolds using natural biomaterials is often carried out using conventional techniques, where the efficiency in mass transport of nutrients and removal of waste products within the construct is compromised. The present study identified silk fibroin (SF) protein as a suitable material for the application of rapid prototyping (RP) or additive manufacturing (AM) technology. Using the indirect RP method, via the use of a mould, SF tissue scaffolds with both macro- and micro-morphological features can be produced and qualitatively examined by spectral-domain optical coherence tomography (SD-OCT). The advanced imaging technique showed the ability to differentiate the cells and SF material by producing high contrasting images, therefore suggesting the method as a feasible alternative to the histological analysis of cell growth within tissue scaffolds. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
Tabassum, Shahina; Al-Mahtab, Mamun; Nessa, Afzalun; Jahan, Munira; Shamim Kabir, Chowdhury Mohammad; Kamal, Mohammad; Cesar Aguilar, Julio
2015-01-01
Background Hepatitis B virus (HBV) infection has many faces. Precore and core promoter mutants resemble inactive carrier status. The identification of hepatitis B core antigen (HBcAg) in hepatocytes may have variable clinical significance. The present study was undertaken to detect HBcAg in chronic hepatitis B (CHB) patients and to assess the efficacy of detection system by indirect immunofluorescence (IIF) and indirect immunoperoxidase (IIP). Materials and methods The study was done in 70 chronic HBV-infected patients. Out of 70 patients, eight (11.4%) were hepatitis B e antigen (HBeAg) positive and 62 (88.57%) were HBeAg negative. Hepatitis B core antigen was detected by indirect immunofluorescence (IIF) and indirect immunoperoxidase (IIP) methods in liver tissue. Results All HBeAg positive patients expressed HBcAg by both IIF and IIP methods. Out of 62 patients with HBeAg-negative CHB, HBcAg was detected by IIF in 55 (88.7%) patients and by IIP in 51 (82.26%) patients. A positive relation among viral load and HBcAg detection was also found. This was more evident in the case of HBeAg negative patients and showed a positive relation with HBV DNA levels. Conclusion Hepatitis B core antigen can be detected using the IIF from formalin fixed paraffin block preparation and also by IIP method. This seems to reflect the magnitudes of HBV replication in CHB. How to cite this article Raihan R, Tabassum S, Al-Mahtab M, Nessa A, Jahan M, Kabir CMS, Kamal M, Aguilar JC. Hepatitis B Core Antigen in Hepatocytes of Chronic Hepatitis B: Comparison between Indirect Immunofluorescence and Immunoperoxidase Method. Euroasian J Hepato-Gastroenterol 2015;5(1):7-10. PMID:29201677
Samant, Sanjiv S; Gopal, Arun
2006-09-01
Megavoltage x-ray imaging suffers from reduced image quality due to low differential x-ray attenuation and large Compton scatter compared with kilovoltage imaging. Notwithstanding this, electronic portal imaging devices (EPIDs) are now widely used in portal verification in radiotherapy as they offer significant advantages over film, including immediate digital imaging and superior contrast range. However video-camera-based EPIDs (VEPIDs) are limited by problems of low light collection efficiency and significant light scatter, leading to reduced contrast and spatial resolution. Indirect and direct detection-based flat-panel EPIDs have been developed to overcome these limitations. While flat-panel image quality has been reported to exceed that achieved with portal film, these systems have detective quantum efficiency (DQE) limited by the thin detection medium and are sensitive to radiation damage to peripheral read-out electronics. An alternative technology for high-quality portal imaging is presented here: kinesatic charge detection (KCD). The KCD is a scanning tri-electrode ion-chamber containing high-pressure noble gas (xenon at 100 atm) used in conjunction with a strip-collimated photon beam. The chamber is scanned across the patient, and an external electric field is used to regulate the cation drift velocity. By matching the scanning velocity with that of the cation (i.e., ion) drift velocity, the cations remain static in the object frame of reference, allowing temporal integration of the signal. The KCD offers several advantages as a portal imaging system. It has a thick detector geometry with an active detection depth of 6.1 cm, compared to the sub-millimeter thickness of the phosphor layer in conventional phosphor screens, leading to an order of magnitude advantage in quantum efficiency (>0.3). The unique principle of and the use of the scanning strip-collimated x-ray beam provide further integration of charges in time, reduced scatter, and a significantly reduced imaging dose, enhancing the imaging signal-to-noise ratio (SNR) and leading to high DQE. While thick detectors usually suffer from reduced spatial resolution, the KCD provides good spatial resolution due to high gas pressure that limits the spread of scattered electrons, and a strip-collimated beam that significantly reduces the inclusion of scatter in the imaging signal. A 10 cm wide small-field-of-view (SFOV) prototype of the KCD is presented with a complete analysis of its imaging performance. Measurements of modulation transfer function (MTF), noise power spectrum (NPS), and DQE were in good agreement with Monte Carlo simulations. Imaging signal loss from recombination within the KCD chamber was measured at different gas pressures, ion drift velocities, and strip-collimation widths. Image quality for the prototype KCD was also observed with anthropomorphic phantom imaging in comparison with various commercial and research portal imaging systems, including VEPID, flat-panel imager, and conventional and high contrast film systems. KCD-based imaging provided very good contrast and good spatial resolution at very low imaging dose (0.1 cGy per image). For the prototype KCD, measurements yielded DQE(0)=0.19 and DQE(1 cy/mm)=0.004.
Lozano, Cecil; Ravishankar, Vijay; Lee, Jisoo; Mahoney, Diane
2018-01-01
Background Individuals living with advancing stages of dementia (persons with dementia, PWDs) or other cognitive disorders do not have the luxury of remembering how to perform basic day-to-day activities, which in turn makes them increasingly dependent on the assistance of caregivers. Dressing is one of the most common and stressful activities provided by caregivers because of its complexity and privacy challenges posed during the process. Objective In preparation for in-home trials with PWDs, the aim of this study was to develop and evaluate a prototype intelligent system, the DRESS prototype, to assess its ability to provide automated assistance with dressing that can afford independence and privacy to individual PWDs and potentially provide additional freedom to their caregivers (family members and professionals). Methods This laboratory study evaluated the DRESS prototype’s capacity to detect dressing events. These events were engaged in by 11 healthy participants simulating common correct and incorrect dressing scenarios. The events ranged from donning a shirt and pants inside out or backwards to partial dressing—typical issues that challenge a PWD and their caregivers. Results A set of expected detections for correct dressing was prepared via video analysis of all participants’ dressing behaviors. In the initial phases of donning either shirts or pants, the DRESS prototype missed only 4 out of 388 expected detections. The prototype’s ability to recognize other missing detections varied across conditions. There were also some unexpected detections such as detection of the inside of a shirt as it was being put on. Throughout the study, detection of dressing events was adversely affected by the relatively smaller effective size of the markers at greater distances. Although the DRESS prototype incorrectly identified 10 of 22 cases for shirts, the prototype preformed significantly better for pants, incorrectly identifying only 5 of 22 cases. Further analyses identified opportunities to improve the DRESS prototype’s reliability, including increasing the size of markers, minimizing garment folding or occlusions, and optimal positioning of participants with respect to the DRESS prototype. Conclusions This study demonstrates the ability to detect clothing orientation and position and infer current state of dressing using a combination of sensors, intelligent software, and barcode tracking. With improvements identified by this study, the DRESS prototype has the potential to provide a viable option to provide automated dressing support to assist PWDs in maintaining their independence and privacy, while potentially providing their caregivers with the much-needed respite. PMID:29716885
False recognition of facial expressions of emotion: causes and implications.
Fernández-Dols, José-Miguel; Carrera, Pilar; Barchard, Kimberly A; Gacitua, Marta
2008-08-01
This article examines the importance of semantic processes in the recognition of emotional expressions, through a series of three studies on false recognition. The first study found a high frequency of false recognition of prototypical expressions of emotion when participants viewed slides and video clips of nonprototypical fearful and happy expressions. The second study tested whether semantic processes caused false recognition. The authors found that participants made significantly higher error rates when asked to detect expressions that corresponded to semantic labels than when asked to detect visual stimuli. Finally, given that previous research reported that false memories are less prevalent in younger children, the third study tested whether false recognition of prototypical expressions increased with age. The authors found that 67% of eight- to nine-year-old children reported nonpresent prototypical expressions of fear in a fearful context, but only 40% of 6- to 7-year-old children did so. Taken together, these three studies demonstrate the importance of semantic processes in the detection and categorization of prototypical emotional expressions.
Schulte, Berit; Eickmeyer, Holm; Heininger, Alexandra; Juretzek, Stephanie; Karrasch, Matthias; Denis, Olivier; Roisin, Sandrine; Pletz, Mathias W.; Klein, Matthias; Barth, Sandra; Lüdke, Gerd H.; Thews, Anne; Torres, Antoni; Cillóniz, Catia; Straube, Eberhard; Autenrieth, Ingo B.; Keller, Peter M.
2014-01-01
Severe pneumonia remains an important cause of morbidity and mortality. Polymerase chain reaction (PCR) has been shown to be more sensitive than current standard microbiological methods – particularly in patients with prior antibiotic treatment – and therefore, may improve the accuracy of microbiological diagnosis for hospitalized patients with pneumonia. Conventional detection techniques and multiplex PCR for 14 typical bacterial pneumonia-associated pathogens were performed on respiratory samples collected from adult hospitalized patients enrolled in a prospective multi-center study. Patients were enrolled from March until September 2012. A total of 739 fresh, native samples were eligible for analysis, of which 75 were sputa, 421 aspirates, and 234 bronchial lavages. 276 pathogens were detected by microbiology for which a valid PCR result was generated (positive or negative detection result by Curetis prototype system). Among these, 120 were identified by the prototype assay, 50 pathogens were not detected. Overall performance of the prototype for pathogen identification was 70.6% sensitivity (95% confidence interval (CI) lower bound: 63.3%, upper bound: 76.9%) and 95.2% specificity (95% CI lower bound: 94.6%, upper bound: 95.7%). Based on the study results, device cut-off settings were adjusted for future series production. The overall performance with the settings of the CE series production devices was 78.7% sensitivity (95% CI lower bound: 72.1%) and 96.6% specificity (95% CI lower bound: 96.1%). Time to result was 5.2 hours (median) for the prototype test and 43.5 h for standard-of-care. The Pneumonia Application provides a rapid and moderately sensitive assay for the detection of pneumonia-causing pathogens with minimal hands-on time. Trial Registration Deutsches Register Klinischer Studien (DRKS) DRKS00005684 PMID:25397673
Liu, Yong-Qiang; Yu, Hong
2016-08-01
Indirect ultraviolet detection was conducted in ultraviolet-absorption-agent-added mobile phase to complete the detection of the absence of ultraviolet absorption functional group in analytes. Compared with precolumn derivatization or postcolumn derivatization, this method can be widely used, has the advantages of simple operation and good linear relationship. Chromatographic separation of Li(+) , Na(+) , K(+) , and NH4 (+) was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid/organic solvent as the mobile phase, in which imidazolium ionic liquids acted as ultraviolet absorption reagent and eluting agent. The retention behaviors of four kinds of cations are discussed, and the mechanism of separation and detection are described. The main factors influencing the separation and detection were the background ultraviolet absorption reagent and the concentration of hydrogen ion in the ion chromatography-indirect ultraviolet detection. The successful separation and detection of Li(+) , Na(+) , K(+) , and NH4 (+) within 13 min was achieved using the selected chromatographic conditions, and the detection limits (S/N = 3) were 0.02, 0.11, 0.30, and 0.06 mg/L, respectively. A new separation and analysis method of alkali metal ions and ammonium by ion chromatography with indirect ultraviolet detection method was developed, and the application range of ionic liquid was expanded. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ares I-X Ground Diagnostic Prototype
NASA Technical Reports Server (NTRS)
Schwabacher, Mark; Martin, Rodney; Waterman, Robert; Oostdyk, Rebecca; Ossenfort, John; Matthews, Bryan
2010-01-01
Automating prelaunch diagnostics for launch vehicles offers three potential benefits. First, it potentially improves safety by detecting faults that might otherwise have been missed so that they can be corrected before launch. Second, it potentially reduces launch delays by more quickly diagnosing the cause of anomalies that occur during prelaunch processing. Reducing launch delays will be critical to the success of NASA's planned future missions that require in-orbit rendezvous. Third, it potentially reduces costs by reducing both launch delays and the number of people needed to monitor the prelaunch process. NASA is currently developing the Ares I launch vehicle to bring the Orion capsule and its crew of four astronauts to low-earth orbit on their way to the moon. Ares I-X will be the first unmanned test flight of Ares I. It is scheduled to launch on October 27, 2009. The Ares I-X Ground Diagnostic Prototype is a prototype ground diagnostic system that will provide anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage thrust vector control (TVC) and for the associated ground hydraulics while it is in the Vehicle Assembly Building (VAB) at John F. Kennedy Space Center (KSC) and on the launch pad. It will serve as a prototype for a future operational ground diagnostic system for Ares I. The prototype combines three existing diagnostic tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool that is commercially produced by Qualtech Systems, Inc. It uses a qualitative model of failure propagation to perform fault isolation and diagnostics. We adapted an existing TEAMS model of the TVC to use for diagnostics and developed a TEAMS model of the ground hydraulics. The second tool, Spacecraft Health Inference Engine (SHINE), is a rule-based expert system developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification. The prototype uses the outputs of SHINE as inputs to TEAMS. The third tool, the Inductive Monitoring System (IMS), is an anomaly detection tool developed at NASA Ames Research Center and is currently used to monitor the International Space Station Control Moment Gyroscopes. IMS automatically "learns" a model of historical nominal data in the form of a set of clusters and signals an alarm when new data fails to match this model. IMS offers the potential to detect faults that have not been modeled. The three tools have been integrated and deployed to Hangar AE at KSC where they interface with live data from the Ares I-X vehicle and from the ground hydraulics. The outputs of the tools are displayed on a console in Hangar AE, one of the locations from which the Ares I-X launch will be monitored. The full paper will describe how the prototype performed before the launch. It will include an analysis of the prototype's accuracy, including false-positive rates, false-negative rates, and receiver operating characteristics (ROC) curves. It will also include a description of the prototype's computational requirements, including CPU usage, main memory usage, and disk usage. If the prototype detects any faults during the prelaunch period then the paper will include a description of those faults. Similarly, if the prototype has any false alarms then the paper will describe them and will attempt to explain their causes.
NASA Astrophysics Data System (ADS)
Mariani, Stefano; Nguyen, Thompson V.; Sternini, Simone; Lanza di Scalea, Francesco; Fateh, Mahmood; Wilson, Robert
2016-04-01
The University of California at San Diego (UCSD), under a Federal Railroad Administration (FRA) Office of Research and Development (R&D) grant, is developing a system for high-speed and non-contact rail defect detection. A prototype using an ultrasonic air-coupled guided wave signal generation and air-coupled signal detection, paired with a real-time statistical analysis algorithm, has been realized. This system requires a specialized filtering approach based on electrical impedance matching due to the inherently poor signal-to-noise ratio of air-coupled ultrasonic measurements in rail steel. Various aspects of the prototype have been designed with the aid of numerical analyses. In particular, simulations of ultrasonic guided wave propagation in rails have been performed using a Local Interaction Simulation Approach (LISA) algorithm. The system's operating parameters were selected based on Receiver Operating Characteristic (ROC) curves, which provide a quantitative manner to evaluate different detection performances based on the trade-off between detection rate and false positive rate. The prototype based on this technology was tested in October 2014 at the Transportation Technology Center (TTC) in Pueblo, Colorado, and again in November 2015 after incorporating changes based on lessons learned. Results from the 2015 field test are discussed in this paper.
Liu, Xiao; Zhu, Ling; Shi, Xiaohong; Xu, Zhiwen; Mei, Miao; Xu, Weiwei; Zhou, Yuancheng; Guo, Wanzhu; Wang, Xiaoyu
2012-12-01
The major epitope region of the glycoprotein B (gB) gene of the porcine cytomegalovirus (PCMV), with a length of 270 bp, was cloned and expressed in Escherichia coli Rosetta (DE3). The major gB epitope was detected using an agar gel precipitation and Western blot analysis with the polyclonal antibodies specific for the major epitope. An indirect-blocking enzyme-linked immunosorbent assay (ELISA) was developed using the expressed major gB epitope as a coating antigen for the detection of PCMV antibodies. The results of the tests show that the indirect-blocking ELISA has 98% specificity and 97.8% sensitivity. No cross-reactions were observed between the major gB epitope and the antibodies against other virus, which indicates that the gB epitope is specific for PCMV antibodies. The indirect-blocking ELISA is a highly specific, sensitive method for detecting anti-PCMV gB antibodies. Copyright © 2012 Elsevier B.V. All rights reserved.
Ackermann, M.; Albert, A.; Anderson, B.; ...
2014-02-11
The dwarf spheroidal satellite galaxies of the Milky Way are some of the most dark-matter-dominated objects known. Due to their proximity, high dark matter content, and lack of astrophysical backgrounds, dwarf spheroidal galaxies are widely considered to be among the most promising targets for the indirect detection of dark matter via γ rays. We report on γ -ray observations of 25 Milky Way dwarf spheroidal satellite galaxies based on 4 years of Fermi Large Area Telescope (LAT) data. None of the dwarf galaxies are significantly detected in γ rays, and we present γ -ray flux upper limits between 500 MeVmore » and 500 GeV. We determine the dark matter content of 18 dwarf spheroidal galaxies from stellar kinematic data and combine LAT observations of 15 dwarf galaxies to constrain the dark matter annihilation cross section. Furthermore, we set some of the tightest constraints to date on the annihilation of dark matter particles with masses between 2 GeV and 10 TeV into prototypical standard model channels. We also find these results to be robust against systematic uncertainties in the LAT instrument performance, diffuse γ -ray background modeling, and assumed dark matter density profile.« less
Wei, Kang-Lin; Wen, Zhi-Yu; Guo, Jian; Chen, Song-Bo
2012-07-01
Aiming at the monitoring and protecting of water resource environment, a multi-parameter water quality monitoring microsystem based on microspectrometer was put forward in the present paper. The microsystem is mainly composed of MOEMS microspectrometer, flow paths system and embedded measuring & controlling system. It has the functions of self-injecting samples and detection regents, automatic constant temperature, self -stirring, self- cleaning and samples' spectrum detection. The principle prototype machine of the microsystem was developed, and its structure principle was introduced in the paper. Through experiment research, it was proved that the principle prototype machine can rapidly detect quite a few water quality parameters and can meet the demands of on-line water quality monitoring, moreover, the principle prototype machine has strong function expansibility.
Prototype active scanner for nighttime oil spill mapping and classification
NASA Technical Reports Server (NTRS)
Sandness, G. A.; Ailes, S. B.
1977-01-01
A prototype, active, aerial scanner system was constructed for nighttime water pollution detection and nighttime multispectral imaging of the ground. An arc lamp was used to produce the transmitted light and four detector channels provided a multispectral measurement capability. The feasibility of the design concept was demonstrated by laboratory and flight tests of the prototype system.
1979-12-01
used to reduce costs ). The orbital data from the prototype ion composi- tion telescope will not only be of great scientific interest -pro- viding for...active device whose transfer function may be almost arbitrarily defined, and cost and production trends permit contemplation of networks containing...developing solid-state television camera systems based on CCD imagers. RICA hopes to produce a $500 color camera for consumer use. Fairchild and Texas
McCall, Brian; Olsen, Randall J; Nelles, Nicole J; Williams, Dawn L; Jackson, Kevin; Richards-Kortum, Rebecca; Graviss, Edward A; Tkaczyk, Tomasz S
2014-03-01
A prototype miniature objective that was designed for a point-of-care diagnostic array microscope for detection of Mycobacterium tuberculosis and previously fabricated and presented in a proof of concept is evaluated for its effectiveness in detecting acid-fast bacteria. To evaluate the ability of the microscope to resolve submicron features and details in the image of acid-fast microorganisms stained with a fluorescent dye, and to evaluate the accuracy of clinical diagnoses made with digital images acquired with the objective. The lens prescription data for the microscope design are presented. A test platform is built by combining parts of a standard microscope, a prototype objective, and a digital single-lens reflex camera. Counts of acid-fast bacteria made with the prototype objective are compared to counts obtained with a standard microscope over matched fields of view. Two sets of 20 smears, positive and negative, are diagnosed by 2 pathologists as sputum smear positive or sputum smear negative, using both a standard clinical microscope and the prototype objective under evaluation. The results are compared to a reference diagnosis of the same sample. More bacteria are counted in matched fields of view in digital images taken with the prototype objective than with the standard clinical microscope. All diagnostic results are found to be highly concordant. An array microscope built with this miniature lens design will be able to detect M tuberculosis with high sensitivity and specificity.
A hydrophone prototype for ultra high energy neutrino acoustic detection
NASA Astrophysics Data System (ADS)
Cotrufo, A.; Plotnikov, A.; Yershova, O.; Anghinolfi, M.; Piombo, D.
2009-06-01
The design of an air-backed fiber-optic hydrophone is presented. With respect to the previous models this prototype is optimized to provide a bandwidth sufficiently large to detect acoustic signals produced by high energy hadronic showers in water. In addiction to the geometrical configuration and to the choice of the materials, the preliminary results of the measured performances in air are presented.
Real-time 3D change detection of IEDs
NASA Astrophysics Data System (ADS)
Wathen, Mitch; Link, Norah; Iles, Peter; Jinkerson, John; Mrstik, Paul; Kusevic, Kresimir; Kovats, David
2012-06-01
Road-side bombs are a real and continuing threat to soldiers in theater. CAE USA recently developed a prototype Volume based Intelligence Surveillance Reconnaissance (VISR) sensor platform for IED detection. This vehicle-mounted, prototype sensor system uses a high data rate LiDAR (1.33 million range measurements per second) to generate a 3D mapping of roadways. The mapped data is used as a reference to generate real-time change detection on future trips on the same roadways. The prototype VISR system is briefly described. The focus of this paper is the methodology used to process the 3D LiDAR data, in real-time, to detect small changes on and near the roadway ahead of a vehicle traveling at moderate speeds with sufficient warning to stop the vehicle at a safe distance from the threat. The system relies on accurate navigation equipment to geo-reference the reference run and the change-detection run. Since it was recognized early in the project that detection of small changes could not be achieved with accurate navigation solutions alone, a scene alignment algorithm was developed to register the reference run with the change detection run prior to applying the change detection algorithm. Good success was achieved in simultaneous real time processing of scene alignment plus change detection.
Review of indirect detection of dark matter with neutrinos
NASA Astrophysics Data System (ADS)
Danninger, Matthias
2017-09-01
Dark Matter could be detected indirectly through the observation of neutrinos produced in dark matter self-annihilations or decays. Searches for such neutrino signals have resulted in stringent constraints on the dark matter self-annihilation cross section and the scattering cross section with matter. In recent years these searches have made significant progress in sensitivity through new search methodologies, new detection channels, and through the availability of rich datasets from neutrino telescopes and detectors, like IceCube, ANTARES, Super-Kamiokande, etc. We review recent experimental results and put them in context with respect to other direct and indirect dark matter searches. We also discuss prospects for discoveries at current and next generation neutrino detectors.
Yang, Li; Wang, Guobao; Qi, Jinyi
2016-04-01
Detecting cancerous lesions is a major clinical application of emission tomography. In a previous work, we studied penalized maximum-likelihood (PML) image reconstruction for lesion detection in static PET. Here we extend our theoretical analysis of static PET reconstruction to dynamic PET. We study both the conventional indirect reconstruction and direct reconstruction for Patlak parametric image estimation. In indirect reconstruction, Patlak parametric images are generated by first reconstructing a sequence of dynamic PET images, and then performing Patlak analysis on the time activity curves (TACs) pixel-by-pixel. In direct reconstruction, Patlak parametric images are estimated directly from raw sinogram data by incorporating the Patlak model into the image reconstruction procedure. PML reconstruction is used in both the indirect and direct reconstruction methods. We use a channelized Hotelling observer (CHO) to assess lesion detectability in Patlak parametric images. Simplified expressions for evaluating the lesion detectability have been derived and applied to the selection of the regularization parameter value to maximize detection performance. The proposed method is validated using computer-based Monte Carlo simulations. Good agreements between the theoretical predictions and the Monte Carlo results are observed. Both theoretical predictions and Monte Carlo simulation results show the benefit of the indirect and direct methods under optimized regularization parameters in dynamic PET reconstruction for lesion detection, when compared with the conventional static PET reconstruction.
USDA-ARS?s Scientific Manuscript database
An indirect capture model assay using colloidal Au nanoparticles is demonstrated for surface enhanced Raman scattering (SERS) spectroscopy detection of DNA. The sequence targeted for capture is derived from the West Nile Virus (WNV) RNA genome and was selected on the basis of exhibiting minimal seco...
First Results from the DUNE 35-ton Prototype using Cosmics
NASA Astrophysics Data System (ADS)
Insler, Jonathan; DUNE Collaboration
2016-03-01
The 35-ton prototype for the Deep Underground Neutrino Experiment (DUNE) Far Detector is a single-phase liquid argon time projection chamber (LAr-TPC) integrated detector that will take cosmics data for a two month run beginning in February 2016. The 35-ton prototype will characterize DUNE's Far Detector technology performance and provide a sample of real data for DUNE reconstruction algorithms. The 35-ton prototype has two drift volumes of lengths 2.23 m and 0.23 m on either side of its anode plane assembly (APA) and makes use of wire planes with wrapped wires and a photon detection system (PDS) utilizing photon detection panels read out by silicon photomultipliers (SiPMs). Data from the 35-ton LAr detector are expected to provide rich information on scintillation light and charged particle tracks. We present a preliminary analysis of cosmics data taken with the 35-ton detector with a focus on stopping muons.
Rai, Satish C; Wang, Kai; Ding, Yong; Marmon, Jason K; Bhatt, Manish; Zhang, Yong; Zhou, Weilie; Wang, Zhong Lin
2015-06-23
A high-performance broad band UV/visible photodetector has been successfully fabricated on a fully wide bandgap ZnO/ZnS type-II heterojunction core/shell nanowire array. The device can detect photons with energies significantly smaller (2.2 eV) than the band gap of ZnO (3.2 eV) and ZnS (3.7 eV), which is mainly attributed to spatially indirect type-II transition facilitated by the abrupt interface between the ZnO core and ZnS shell. The performance of the device was further enhanced through the piezo-phototronic effect induced lowering of the barrier height to allow charge carrier transport across the ZnO/ZnS interface, resulting in three orders of relative responsivity change measured at three different excitation wavelengths (385, 465, and 520 nm). This work demonstrates a prototype UV/visible photodetector based on the truly wide band gap semiconducting 3D core/shell nanowire array with enhanced performance through the piezo-phototronic effect.
MARIA M4: clinical evaluation of a prototype ultrawideband radar scanner for breast cancer detection
Preece, Alan W.; Craddock, Ian; Shere, Mike; Jones, Lyn; Winton, Helen L.
2016-01-01
Abstract. A microwave imaging system has been developed as a clinical diagnostic tool operating in the 3- to 8-GHz region using multistatic data collection. A total of 86 patients recruited from a symptomatic breast care clinic were scanned with a prototype design. The resultant three-dimensional images have been compared “blind” with available ultrasound and mammogram images to determine the detection rate. Images show the location of the strongest signal, and this corresponded in both older and younger women, with sensitivity of >74%, which was found to be maintained in dense breasts. The pathway from clinical prototype to clinical evaluation is outlined. PMID:27446970
NASA Astrophysics Data System (ADS)
Decho, Alan W.; Beckman, Erin M.; Chandler, G. Thomas; Kawaguchi, Tomohiro
2008-06-01
An indirect immunofluorescence approach was developed using semiconductor quantum dot nanocrystals to label and detect a specific bacterial serotype of the bacterial human pathogen Vibrio parahaemolyticus, attached to small marine animals (i.e. benthic harpacticoid copepods), which are suspected pathogen carriers. This photostable labeling method using nanotechnology will potentially allow specific serotypes of other bacterial pathogens to be detected with high sensitivity in a range of systems, and can be easily applied for sensitive detection to other Vibrio species such as Vibrio cholerae.
A Novel Anti-Pollution Filter for Volatile Agents During Cardiopulmonary Bypass: Preliminary Tests.
Nigro Neto, Caetano; Landoni, Giovanni; Tardelli, Maria Angela
2017-08-01
Concerns regarding pollution of the operating room by volatile anesthetics and effects on atmospheric ozone depletion exist. Volatile agents commonly are used during cardiopulmonary bypass to provide anesthesia independent of any supposed myocardial protective effects. The authors' aim was to create and to assess the performance of a prototype filter for volatile agents to be connected to the cardiopulmonary bypass circuit to avoid the emission of volatile agents to the operating room, and also to the environment without causing damage to the membrane oxygenator. Observational trial. University hospital. Prototype filter for volatile agents. The prototype filter was tested in a single ex vivo experiment. The main data measured during the test were pressure drop to detect interference with the performance of the oxygenator, back pressure to detect overpressure to the outlet gas jacket of the oxygenator, analysis of exhaled sevoflurane after the membrane oxygenator, and after the filter to detect any presence of sevoflurane. The prototype filter adsorbed the sevoflurane eliminated through the outlet portion of the oxygenator. During the entire test, the back pressure remained constant (4 mmHg) and pressure drop varied from 243 mmHg to 247 mmHg. The prototype filter was considered suitable to absorb the sevoflurane, and it did not cause an overpressure to the membrane oxygenator during the test. Copyright © 2017 Elsevier Inc. All rights reserved.
The prototype detection unit of the KM3NeT detector
NASA Astrophysics Data System (ADS)
Adrián-Martínez, S.; Ageron, M.; Aharonian, F.; Aiello, S.; Albert, A.; Ameli, F.; Anassontzis, E. G.; Androulakis, G. C.; Anghinolfi, M.; Anton, G.; Anvar, S.; Ardid, M.; Avgitas, T.; Balasi, K.; Band, H.; Barbarino, G.; Barbarito, E.; Barbato, F.; Baret, B.; Baron, S.; Barrios, J.; Belias, A.; Berbee, E.; van den Berg, A. M.; Berkien, A.; Bertin, V.; Beurthey, S.; van Beveren, V.; Beverini, N.; Biagi, S.; Biagioni, A.; Bianucci, S.; Billault, M.; Birbas, A.; Boer Rookhuizen, H.; Bormuth, R.; Bouché, V.; Bouhadef, B.; Bourlis, G.; Boutonnet, C.; Bouwhuis, M.; Bozza, C.; Bruijn, R.; Brunner, J.; Cacopardo, G.; Caillat, L.; Calamai, M.; Calvo, D.; Capone, A.; Caramete, L.; Caruso, F.; Cecchini, S.; Ceres, A.; Cereseto, R.; Champion, C.; Château, F.; Chiarusi, T.; Christopoulou, B.; Circella, M.; Classen, L.; Cocimano, R.; Coleiro, A.; Colonges, S.; Coniglione, R.; Cosquer, A.; Costa, M.; Coyle, P.; Creusot, A.; Cuttone, G.; D'Amato, C.; D'Amico, A.; De Bonis, G.; De Rosa, G.; Deniskina, N.; Destelle, J.-J.; Distefano, C.; Di Capua, F.; Donzaud, C.; Dornic, D.; Dorosti-Hasankiadeh, Q.; Drakopoulou, E.; Drouhin, D.; Drury, L.; Durand, D.; Eberl, T.; Elsaesser, D.; Enzenhöfer, A.; Fermani, P.; Fusco, L. A.; Gajanana, D.; Gal, T.; Galatà, S.; Garufi, F.; Gebyehu, M.; Giordano, V.; Gizani, N.; Gracia Ruiz, R.; Graf, K.; Grasso, R.; Grella, G.; Grmek, A.; Habel, R.; van Haren, H.; Heid, T.; Heijboer, A.; Heine, E.; Henry, S.; Hernández-Rey, J. J.; Herold, B.; Hevinga, M. A.; van der Hoek, M.; Hofestädt, J.; Hogenbirk, J.; Hugon, C.; Hößl, J.; Imbesi, M.; James, C. W.; Jansweijer, P.; Jochum, J.; de Jong, M.; Jongen, M.; Kadler, M.; Kalekin, O.; Kappes, A.; Kappos, E.; Katz, U.; Kavatsyuk, O.; Keller, P.; Kieft, G.; Koffeman, E.; Kok, H.; Kooijman, P.; Koopstra, J.; Korporaal, A.; Kouchner, A.; Kreykenbohm, I.; Kulikovskiy, V.; Lahmann, R.; Lamare, P.; Larosa, G.; Lattuada, D.; Le Provost, H.; Leismüller, K. P.; Leisos, A.; Lenis, D.; Leonora, E.; Lindsey Clark, M.; Llorens Alvarez, C. D.; Löhner, H.; Lonardo, A.; Loucatos, S.; Louis, F.; Maccioni, E.; Mannheim, K.; Manolopoulos, K.; Margiotta, A.; Mariş, O.; Markou, C.; Martínez-Mora, J. A.; Martini, A.; Masullo, R.; Melis, K. W.; Michael, T.; Migliozzi, P.; Migneco, E.; Miraglia, A.; Mollo, C. M.; Mongelli, M.; Morganti, M.; Mos, S.; Moudden, Y.; Musico, P.; Musumeci, M.; Nicolaou, C.; Nicolau, C. A.; Orlando, A.; Orzelli, A.; Papaikonomou, A.; Papaleo, R.; Păvălaş, G. E.; Peek, H.; Pellegrino, C.; Pellegriti, M. G.; Perrina, C.; Piattelli, P.; Pikounis, K.; Popa, V.; Pradier, Th.; Priede, M.; Pühlhofer, G.; Pulvirenti, S.; Racca, C.; Raffaelli, F.; Randazzo, N.; Rapidis, P. A.; Razis, P.; Real, D.; Resvanis, L.; Reubelt, J.; Riccobene, G.; Rovelli, A.; Saldaña, M.; Samtleben, D. F. E.; Sanguineti, M.; Santangelo, A.; Sapienza, P.; Schmelling, J.; Schnabel, J.; Sciacca, V.; Sedita, M.; Seitz, T.; Sgura, I.; Simeone, F.; Sipala, V.; Spitaleri, A.; Spurio, M.; Stavropoulos, G.; Steijger, J.; Stolarczyk, T.; Stransky, D.; Taiuti, M.; Terreni, G.; Tézier, D.; Théraube, S.; Thompson, L. F.; Timmer, P.; Trasatti, L.; Trovato, A.; Tselengidou, M.; Tsirigotis, A.; Tzamarias, S.; Tzamariudaki, E.; Vallage, B.; Van Elewyck, V.; Vermeulen, J.; Vernin, P.; Vicini, P.; Viola, S.; Vivolo, D.; Werneke, P.; Wiggers, L.; Wilms, J.; de Wolf, E.; van Wooning, R. H. L.; Zonca, E.; Zornoza, J. D.; Zúñiga, J.; Zwart, A.
2016-02-01
A prototype detection unit of the KM3NeT deep-sea neutrino telescope has been installed at 3500m depth 80 km offshore the Italian coast. KM3NeT in its final configuration will contain several hundreds of detection units. Each detection unit is a mechanical structure anchored to the sea floor, held vertical by a submerged buoy and supporting optical modules for the detection of Cherenkov light emitted by charged secondary particles emerging from neutrino interactions. This prototype string implements three optical modules with 31 photomultiplier tubes each. These optical modules were developed by the KM3NeT Collaboration to enhance the detection capability of neutrino interactions. The prototype detection unit was operated since its deployment in May 2014 until its decommissioning in July 2015. Reconstruction of the particle trajectories from the data requires a nanosecond accuracy in the time calibration. A procedure for relative time calibration of the photomultiplier tubes contained in each optical module is described. This procedure is based on the measured coincidences produced in the sea by the ^{40}K background light and can easily be expanded to a detector with several thousands of optical modules. The time offsets between the different optical modules are obtained using LED nanobeacons mounted inside them. A set of data corresponding to 600 h of livetime was analysed. The results show good agreement with Monte Carlo simulations of the expected optical background and the signal from atmospheric muons. An almost background-free sample of muons was selected by filtering the time correlated signals on all the three optical modules. The zenith angle of the selected muons was reconstructed with a precision of about 3°.
Proof of Concept in Disrupted Tactical Networking
2017-09-01
because of the risk of detection. In this study , we design projectile-based mesh networking prototypes as one potential type of short-living network...to communicate because of the risk of detection. In this study , we design projectile-based mesh networking prototypes as one potential type of short...reader with a background in systems-theory. This study is designed using systems theory and uses systems theory as a lens through which to observe
NASA Astrophysics Data System (ADS)
Tian, Wugang; Hu, Jiafei; Pan, Mengchun; Chen, Dixiang; Zhao, Jianqiang
2013-03-01
1/f noise is one of the main noise sources of magnetoresistive (MR) sensors, which can cause intrinsic detection limit at low frequency. To suppress this noise, the solution of flux concentration and vertical motion modulation (VMM) has been proposed. Magnetic hysteresis in MR sensors is another problem, which degrades their response linearity and detection ability. To reduce this impact, the method of pulse magnetization and magnetic compensation field with integrated planar coils has been introduced. A flux concentration and VMM based magnetoresistive prototype sensor with integrated planar coils was fabricated using microelectromechanical-system technology. The response linearity of the prototype sensors is improved from 0.8% to 0.12%. The noise level is reduced near to the thermal noise level, and the low-frequency detection ability of the prototype sensor is enhanced with a factor of more than 80.
Offline detection of broken rotor bars in AC induction motors
NASA Astrophysics Data System (ADS)
Powers, Craig Stephen
ABSTRACT. OFFLINE DETECTION OF BROKEN ROTOR BARS IN AC INDUCTION MOTORS. The detection of the broken rotor bar defect in medium- and large-sized AC induction machines is currently one of the most difficult tasks for the motor condition and monitoring industry. If a broken rotor bar defect goes undetected, it can cause a catastrophic failure of an expensive machine. If a broken rotor bar defect is falsely determined, it wastes time and money to physically tear down and inspect the machine only to find an incorrect diagnosis. Previous work in 2009 at Baker/SKF-USA in collaboration with the Korea University has developed a prototype instrument that has been highly successful in correctly detecting the broken rotor bar defect in ACIMs where other methods have failed. Dr. Sang Bin and his students at the Korea University have been using this prototype instrument to help the industry save money in the successful detection of the BRB defect. A review of the current state of motor conditioning and monitoring technology for detecting the broken rotor bar defect in ACIMs shows improved detection of this fault is still relevant. An analysis of previous work in the creation of this prototype instrument leads into the refactoring of the software and hardware into something more deployable, cost effective and commercially viable.
Wang, Yicun; Gao, Xiang; Zhi Gang, J U; Liu, Jingyuan; Dong, Shuai; Wang, Li
2013-01-01
The secreted aspartyl proteinases 2 (Sap2) of Candida albicans (C. albicans) is a potential marker of candididasis. It is a virulence factor associated with adherence and tissue invasion. In order to detect Sap2 in clinical sera, we developed an indirect competitive enzyme-linked immunosorbent assay (ELISA). Polyclonal antibodies were produced for Sap2 by injecting Sap2 into a New Zealand White inbred rabbit. They could be used at a dilution exceeding 1:1200 in an indirect ELISA, and detected Sap2 concentration up to 1 ng/mL. Of the 286 cancer serum samples tested, 16.8% were found as candidiasis. The test was simple and economical to perform and had a level of sensitivity for detection of low-titer positive sera; thus, it may be proven to be of value in epidemiological studies on candidiasis.
Turner, E S; Pruzansky, J J; Patterson, R; Zeiss, C R; Roberts, M
1980-02-01
Utilizing trimellityl-erythrocytes (TM-E), antibodies were detected in sera of seven workers with trimellitic anhydride (TMA) induced airway syndromes by direct haemagglutination, indirect haemagglutination with anti-human IgG, IgA or IgM or by haemolysis. Detectable levels of antibody were obtained with all three methods. The most sensitive technique was indirect haemagglutination using anti-IgG. When added as an inhibitor, TM-human serum albumin produced a 10- to 800-fold reduction in titres. TM-ovalbumin of similar epitope density was less inhibitory and sodium trimellitate the least inhibitory on a molar basis. All of the assays using haptenized human red cells were also capable of detecting anti-TM antibodies in Rhesus monkeys whose airways had been exposed to TMA. These assays are useful for detecting anti-TM antibodies and may also be adapted to demonstrate antibodies induced against other inhaled haptens in sera of environmentally exposed individuals or in animal models of such exposure.
Methods of DNA methylation detection
NASA Technical Reports Server (NTRS)
Maki, Wusi Chen (Inventor); Filanoski, Brian John (Inventor); Mishra, Nirankar (Inventor); Rastogi, Shiva (Inventor)
2010-01-01
The present invention provides for methods of DNA methylation detection. The present invention provides for methods of generating and detecting specific electronic signals that report the methylation status of targeted DNA molecules in biological samples.Two methods are described, direct and indirect detection of methylated DNA molecules in a nano transistor based device. In the direct detection, methylated target DNA molecules are captured on the sensing surface resulting in changes in the electrical properties of a nano transistor. These changes generate detectable electronic signals. In the indirect detection, antibody-DNA conjugates are used to identify methylated DNA molecules. RNA signal molecules are generated through an in vitro transcription process. These RNA molecules are captured on the sensing surface change the electrical properties of nano transistor thereby generating detectable electronic signals.
Compact, cost-effective and field-portable microscope prototype based on MISHELF microscopy
NASA Astrophysics Data System (ADS)
Sanz, Martín; Picazo-Bueno, José Ángel; Granero, Luis; García, Javier; Micó, Vicente
2017-02-01
We report on a reduced cost, portable and compact prototype design of lensless holographic microscope with an illumination/detection scheme based on wavelength multiplexing, working with single hologram acquisition and using a fast convergence algorithm for image processing. All together, MISHELF (initials coming from Multi-Illumination Single-Holographic-Exposure Lensless Fresnel) microscopy allows the recording of three Fresnel domain diffraction patterns in a single camera snap-shot incoming from illuminating the sample with three coherent lights at once. Previous implementations have proposed an illumination/detection procedure based on a tuned (illumination wavelengths centered at the maximum sensitivity of the camera detection channels) configuration but here we report on a detuned (non-centered ones) scheme resulting in prototype miniaturization and cost reduction. Thus, MISHELF microscopy in combination with a novel and fast iterative algorithm allows high-resolution (μm range) phase-retrieved (twin image elimination) quantitative phase imaging of dynamic events (video rate recording speed). The performance of this microscope prototype is validated through experiments using both amplitude (USAF resolution test) and complex (live swine sperm cells and flowing microbeads) samples. The proposed method becomes in an alternative instrument improving some capabilities of existing lensless microscopes.
Compact, cost-effective and field-portable microscope prototype based on MISHELF microscopy
Sanz, Martín; Picazo-Bueno, José Ángel; Granero, Luis; García, Javier; Micó, Vicente
2017-01-01
We report on a reduced cost, portable and compact prototype design of lensless holographic microscope with an illumination/detection scheme based on wavelength multiplexing, working with single hologram acquisition and using a fast convergence algorithm for image processing. All together, MISHELF (initials coming from Multi-Illumination Single-Holographic-Exposure Lensless Fresnel) microscopy allows the recording of three Fresnel domain diffraction patterns in a single camera snap-shot incoming from illuminating the sample with three coherent lights at once. Previous implementations have proposed an illumination/detection procedure based on a tuned (illumination wavelengths centered at the maximum sensitivity of the camera detection channels) configuration but here we report on a detuned (non-centered ones) scheme resulting in prototype miniaturization and cost reduction. Thus, MISHELF microscopy in combination with a novel and fast iterative algorithm allows high-resolution (μm range) phase-retrieved (twin image elimination) quantitative phase imaging of dynamic events (video rate recording speed). The performance of this microscope prototype is validated through experiments using both amplitude (USAF resolution test) and complex (live swine sperm cells and flowing microbeads) samples. The proposed method becomes in an alternative instrument improving some capabilities of existing lensless microscopes. PMID:28233829
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cester, D.; Lunardon, M.; Stevanato, L.
2015-07-01
MODES SNM project aimed to carry out technical research in order to develop a prototype for a mobile, modular detection system for radioactive sources and Special Nuclear Materials (SNM). Its main goal was to deliver a tested prototype of a modular mobile system capable of passively detecting weak or shielded radioactive sources with accuracy higher than that of currently available systems. By the end of the project all the objectives have been successfully achieved. Results from the laboratory commissioning and the field tests will be presented. (authors)
Development of Prototype Filovirus Recombinant Antigen Immunoassays
Boisen, Matt L.; Oottamasathien, Darin; Jones, Abigail B.; Millett, Molly M.; Nelson, Diana S.; Bornholdt, Zachary A.; Fusco, Marnie L.; Abelson, Dafna M.; Oda, Shun-ichiro; Hartnett, Jessica N.; Rowland, Megan M.; Heinrich, Megan L.; Akdag, Marjan; Goba, Augustine; Momoh, Mambu; Fullah, Mohammed; Baimba, Francis; Gbakie, Michael; Safa, Sadiki; Fonnie, Richard; Kanneh, Lansana; Cross, Robert W.; Geisbert, Joan B.; Geisbert, Thomas W.; Kulakosky, Peter C.; Grant, Donald S.; Shaffer, Jeffery G.; Schieffelin, John S.; Wilson, Russell B.; Saphire, Erica Ollmann; Branco, Luis M.; Garry, Robert F.; Khan, S. Humarr; Pitts, Kelly R.
2015-01-01
Background. Throughout the 2014–2015 Ebola outbreak in West Africa, major gaps were exposed in the availability of validated rapid diagnostic platforms, protective vaccines, and effective therapeutic agents. These gaps potentiated the development of prototype rapid lateral flow immunodiagnostic (LFI) assays that are true point-of-contact platforms, for the detection of active Ebola infections in small blood samples. Methods. Recombinant Ebola and Marburg virus matrix VP40 and glycoprotein (GP) antigens were used to derive a panel of monoclonal and polyclonal antibodies. Antibodies were tested using a multivariate approach to identify antibody-antigen combinations suitable for enzyme-linked immunosorbent assay (ELISA) and LFI assay development. Results. Polyclonal antibodies generated in goats were superior reagents for capture and detection of recombinant VP40 in test sample matrices. These antibodies were optimized for use in antigen-capture ELISA and LFI assay platforms. Prototype immunoglobulin M (IgM)/immunoglobulin G (IgG) ELISAs were similarly developed that specifically detect Ebola virus–specific antibodies in the serum of experimentally infected nonhuman primates and in blood samples obtained from patients with Ebola from Sierra Leone. Conclusions. The prototype recombinant Ebola LFI assays developed in these studies have sensitivities that are useful for clinical diagnosis of acute ebolavirus infections. The antigen-capture and IgM/IgG ELISAs provide additional confirmatory assay platforms for detecting VP40 and other ebolavirus-specific immunoglobulins. PMID:26232440
Chirped Laser Dispersion Spectroscopy for Remote Open-Path Trace-Gas Sensing
Nikodem, Michal; Wysocki, Gerard
2012-01-01
In this paper we present a prototype instrument for remote open-path detection of nitrous oxide. The sensor is based on a 4.53 μm quantum cascade laser and uses the chirped laser dispersion spectroscopy (CLaDS) technique for molecular concentration measurements. To the best of our knowledge this is the first demonstration of open-path laser-based trace-gas detection using a molecular dispersion measurement. The prototype sensor achieves a detection limit down to the single-ppbv level and exhibits excellent stability and robustness. The instrument characterization, field deployment performance, and the advantages of applying dispersion sensing to sensitive trace-gas detection in a remote open-path configuration are presented. PMID:23443389
Chirped laser dispersion spectroscopy for remote open-path trace-gas sensing.
Nikodem, Michal; Wysocki, Gerard
2012-11-28
In this paper we present a prototype instrument for remote open-path detection of nitrous oxide. The sensor is based on a 4.53 μm quantum cascade laser and uses the chirped laser dispersion spectroscopy (CLaDS) technique for molecular concentration measurements. To the best of our knowledge this is the first demonstration of open-path laser-based trace-gas detection using a molecular dispersion measurement. The prototype sensor achieves a detection limit down to the single-ppbv level and exhibits excellent stability and robustness. The instrument characterization, field deployment performance, and the advantages of applying dispersion sensing to sensitive trace-gas detection in a remote open-path configuration are presented.
A Disposable Tear Glucose Biosensor—Part 2: System Integration and Model Validation
La Belle, Jeffrey T.; Bishop, Daniel K.; Vossler, Stephen R.; Patel, Dharmendra R.; Cook, Curtiss B.
2010-01-01
Background We presented a concept for a tear glucose sensor system in an article by Bishop and colleagues in this issue of Journal of Diabetes Science and Technology. A unique solution to collect tear fluid and measure glucose was developed. Individual components were selected, tested, and optimized, and system error modeling was performed. Further data on prototype testing are now provided. Methods An integrated fluidics portion of the prototype was designed, cast, and tested. A sensor was created using screen-printed sensors integrated with a silicone rubber fluidics system and absorbent polyurethane foam. A simulated eye surface was prepared using fluid-saturated poly(2-hydroxyethyl methacrylate) sheets, and the disposable prototype was tested for both reproducibility at 0, 200, and 400 μM glucose (n = 7) and dynamic range of glucose detection from 0 to 1000 μM glucose. Results From the replicated runs, an established relative standard deviation of 15.8% was calculated at 200 μM and a lower limit of detection was calculated at 43.4 μM. A linear dynamic range was demonstrated from 0 to 1000 μM with an R2 of 99.56%. The previously developed model predicted a 14.9% variation. This compares to the observed variance of 15.8% measured at 200 μM glucose. Conclusion With the newly designed fluidics component, an integrated tear glucose prototype was assembled and tested. Testing of this integrated prototype demonstrated a satisfactory lower limit of detection for measuring glucose concentration in tears and was reproducible across a physiological sampling range. The next step in the device design process will be initial animal studies to evaluate the current prototype for factors such as eye irritation, ease of use, and correlation with blood glucose. PMID:20307390
A disposable tear glucose biosensor-part 2: system integration and model validation.
La Belle, Jeffrey T; Bishop, Daniel K; Vossler, Stephen R; Patel, Dharmendra R; Cook, Curtiss B
2010-03-01
We presented a concept for a tear glucose sensor system in an article by Bishop and colleagues in this issue of Journal of Diabetes Science and Technology. A unique solution to collect tear fluid and measure glucose was developed. Individual components were selected, tested, and optimized, and system error modeling was performed. Further data on prototype testing are now provided. An integrated fluidics portion of the prototype was designed, cast, and tested. A sensor was created using screen-printed sensors integrated with a silicone rubber fluidics system and absorbent polyurethane foam. A simulated eye surface was prepared using fluid-saturated poly(2-hydroxyethyl methacrylate) sheets, and the disposable prototype was tested for both reproducibility at 0, 200, and 400 microM glucose (n = 7) and dynamic range of glucose detection from 0 to 1000 microM glucose. From the replicated runs, an established relative standard deviation of 15.8% was calculated at 200 microM and a lower limit of detection was calculated at 43.4 microM. A linear dynamic range was demonstrated from 0 to 1000 microM with an R(2) of 99.56%. The previously developed model predicted a 14.9% variation. This compares to the observed variance of 15.8% measured at 200 microM glucose. With the newly designed fluidics component, an integrated tear glucose prototype was assembled and tested. Testing of this integrated prototype demonstrated a satisfactory lower limit of detection for measuring glucose concentration in tears and was reproducible across a physiological sampling range. The next step in the device design process will be initial animal studies to evaluate the current prototype for factors such as eye irritation, ease of use, and correlation with blood glucose. (c) 2010 Diabetes Technology Society.
Fall Detection System for the Elderly Based on the Classification of Shimmer Sensor Prototype Data
Ahmed, Moiz; Mehmood, Nadeem; Mehmood, Amir; Rizwan, Kashif
2017-01-01
Objectives Falling in the elderly is considered a major cause of death. In recent years, ambient and wireless sensor platforms have been extensively used in developed countries for the detection of falls in the elderly. However, we believe extra efforts are required to address this issue in developing countries, such as Pakistan, where most deaths due to falls are not even reported. Considering this, in this paper, we propose a fall detection system prototype that s based on the classification on real time shimmer sensor data. Methods We first developed a data set, ‘SMotion’ of certain postures that could lead to falls in the elderly by using a body area network of Shimmer sensors and categorized the items in this data set into age and weight groups. We developed a feature selection and classification system using three classifiers, namely, support vector machine (SVM), K-nearest neighbor (KNN), and neural network (NN). Finally, a prototype was fabricated to generate alerts to caregivers, health experts, or emergency services in case of fall. Results To evaluate the proposed system, SVM, KNN, and NN were used. The results of this study identified KNN as the most accurate classifier with maximum accuracy of 96% for age groups and 93% for weight groups. Conclusions In this paper, a classification-based fall detection system is proposed. For this purpose, the SMotion data set was developed and categorized into two groups (age and weight groups). The proposed fall detection system for the elderly is implemented through a body area sensor network using third-generation sensors. The evaluation results demonstrate the reasonable performance of the proposed fall detection prototype system in the tested scenarios. PMID:28875049
Mu2e transport solenoid prototype design and manufacturing
Fabbricatore, P.; Ambrosio, G.; Cheban, S.; ...
2016-02-08
The Mu2e Transport Solenoid consists of 52 coils arranged in 27 coil modules that form the S-shaped cold mass. Each coil is wound from Al-stabilized NbTi superconductor. The coils are supported by an external structural aluminum shell machined from a forged billet. Most of the coil modules house two coils, with the axis of each coil oriented at an angle of approximately 5° with respect to each other. The coils are indirectly cooled with LHe circulating in tubes welded on the shell. In order to enhance the cooling capacity, pure aluminum sheets connect the inner bore of the coils tomore » the cooling tubes. The coils are placed inside the shell by the means of a shrink-fit procedure. A full-size prototype, with all the features of the full assembly, was successfully manufactured in a collaboration between INFN Genova and Fermilab. In order to ensure an optimal mechanical prestress at the coil-shell interface, the coils are inserted into the shell through a shrink-fitting process. We present the details of the prototype with the design choices as validated by the structural analysis. In conclusion, the fabrication steps are described as well.« less
Expert system prototype developments for NASA-KSC business and engineering applications
NASA Technical Reports Server (NTRS)
Ragusa, James M.; Gonzalez, Avelino J.
1988-01-01
Prototype expert systems developed for a variety of NASA projects in the business/management and engineering domains are discussed. Business-related problems addressed include an assistant for simulating launch vehicle processing, a plan advisor for the acquisition of automated data processing equipment, and an expert system for the identification of customer requirements. Engineering problems treated include an expert system for detecting potential ignition sources in LOX and gaseous-oxygen transportation systems and an expert system for hazardous-gas detection.
X-Ray Scan Detection for Cargo Integrity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Valencia, Juan D.; Miller, Steven D.
ABSTRACT The increase of terrorism and its global impact has made the determination of the contents of cargo containers a necessity. Existing technology allows non-intrusive inspections to determine the contents of a container rapidly and accurately. However, some cargo shipments are exempt from such inspections. Hence, there is a need for a technology that enables rapid and accurate means of detecting whether such containers were non-intrusively inspected. Non-intrusive inspections are most commonly performed utilizing high powered X-ray equipment. The challenge is creating a device that can detect short duration X-ray scans while maintaining a portable, battery powered, low cost, andmore » easy to use platform. The Pacific Northwest National Laboratory (PNNL) has developed a methodology and prototype device focused on this challenge. The prototype, developed by PNNL, is a battery powered electronic device that continuously measures its X-ray and Gamma exposure, calculates the dose equivalent rate, and makes a determination of whether the device has been exposed to the amount of radiation experienced during an X-ray inspection. Once an inspection is detected, the device will record a timestamp of the event and relay the information to authorized personnel via a visual alert, USB connection, and/or wireless communication. The results of this research demonstrate that PNNL’s prototype device can be effective at determining whether a container was scanned by X-ray equipment typically used for cargo container inspections. This paper focuses on laboratory measurements and test results acquired with the PNNL prototype device using several X-ray radiation levels. Keywords: Radiation, Scan, X-ray, Gamma, Detection, Cargo, Container, Wireless, RF« less
Culka, Adam; Osterrothová, Kateřina; Hutchinson, Ian; Ingley, Richard; McHugh, Melissa; Oren, Aharon; Edwards, Howell G. M.; Jehlička, Jan
2014-01-01
A prototype instrument, under development at the University of Leicester, for the future European Space Agency (ESA) ExoMars mission, was used for the analysis of microbial pigments within a stratified gypsum crust from a hypersaline saltern evaporation pond at Eilat (Israel). Additionally, the same samples were analysed using a miniaturized Raman spectrometer, featuring the same 532 nm excitation. The differences in the position of the specific bands, attributed to carotenoid pigments from different coloured layers, were minor when analysed by the ESA prototype instrument; therefore, making it difficult to distinguish among the different pigments. The portable Delta Nu Advantage instrument allowed for the discrimination of microbial carotenoids from the orange/green and purple layers. The purpose of this study was to complement previous laboratory results with new data and experience with portable or handheld Raman systems, even with a dedicated prototype Raman system for the exploration of Mars. The latter is equipped with an excitation wavelength falling within the carotenoid polyene resonance region. The ESA prototype Raman instrument detected the carotenoid pigments (biomarkers) with ease, although further detailed distinctions among them were not achieved. PMID:25368354
Indirect Detection Analysis: Wino Dark Matter Case Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hryczuk, Andrzej; Cholis, Ilias; Iengo, Roberto
2014-07-15
We perform a multichannel analysis of the indirect signals for the Wino Dark Matter, including one-loop electroweak and Sommerfeld enhancement corrections. We derive limits from cosmic ray antiprotons and positrons, from continuum galactic and extragalactic diffuse γ-ray spectra, from the absence of γ-ray line features at the galactic center above 500 GeV in energy, from γ-rays toward nearby dwarf spheroidal galaxies and galaxy clusters, and from CMB power-spectra. Additionally, we show the future prospects for neutrino observations toward the inner Galaxy and from antideuteron searches. For each of these indirect detection probes we include and discuss the relevance of themore » most important astrophysical uncertainties that can impact the strength of the derived limits. We find that the Wino as a dark matter candidate is excluded in the mass range bellow simeq 800 GeV from antiprotons and between 1.8 and 3.5 TeV from the absence of a γ-ray line feature toward the galactic center. Limits from other indirect detection probes confirm the main bulk of the excluded mass ranges.« less
Highly Sensitive Bacteriophage-Based Detection of Brucella abortus in Mixed Culture and Spiked Blood
Sergueev, Kirill V.; Filippov, Andrey A.; Nikolich, Mikeljon P.
2017-01-01
For decades, bacteriophages (phages) have been used for Brucella species identification in the diagnosis and epidemiology of brucellosis. Traditional Brucella phage typing is a multi-day procedure including the isolation of a pure culture, a step that can take up to three weeks. In this study, we focused on the use of brucellaphages for sensitive detection of the pathogen in clinical and other complex samples, and developed an indirect method of Brucella detection using real-time quantitative PCR monitoring of brucellaphage DNA amplification via replication on live Brucella cells. This assay allowed the detection of single bacteria (down to 1 colony-forming unit per milliliter) within 72 h without DNA extraction and purification steps. The technique was equally efficient with Brucella abortus pure culture and with mixed cultures of B. abortus and α-proteobacterial near neighbors that can be misidentified as Brucella spp., Ochrobactrum anthropi and Afipia felis. The addition of a simple short sample preparation step enabled the indirect phage-based detection of B. abortus in spiked blood, with the same high sensitivity. This indirect phage-based detection assay enables the rapid and sensitive detection of live B. abortus in mixed cultures and in blood samples, and can potentially be applied for detection in other clinical samples and other complex sample types. PMID:28604602
Tan, J Y; Chua, C K; Leong, K F
2013-02-01
Advanced scaffold fabrication techniques such as Rapid Prototyping (RP) are generally recognized to be advantageous over conventional fabrication methods in terms architectural control and reproducibility. Yet, most RP techniques tend to suffer from resolution limitations which result in scaffolds with uncontrollable, random-size pores and low porosity, albeit having interconnected channels which is characteristically present in most RP scaffolds. With the increasing number of studies demonstrating the profound influences of scaffold pore architecture on cell behavior and overall tissue growth, a scaffold fabrication method with sufficient architectural control becomes imperative. The present study demonstrates the use of RP fabrication techniques to create scaffolds having interconnected channels as well as controllable micro-size pores. Adopted from the concepts of porogen leaching and indirect RP techniques, the proposed fabrication method uses monodisperse microspheres to create an ordered, hexagonal closed packed (HCP) array of micro-pores that surrounds the existing channels of the RP scaffold. The pore structure of the scaffold is shaped using a single sacrificial construct which comprises the microspheres and a dissolvable RP mold that were sintered together. As such, the size of pores as well as the channel configuration of the scaffold can be tailored based on the design of the RP mold and the size of microspheres used. The fabrication method developed in this work can be a promising alternative way of preparing scaffolds with customized pore structures that may be required for specific studies concerning cell-scaffold interactions.
Indirect dynamics in SN2@N: insight into the influence of central atoms.
Liu, Xu; Zhao, Chenyang; Yang, Li; Zhang, Jiaxu; Sun, Rui
2017-08-30
Central atoms have a significant influence on the reaction kinetics and dynamics of nucleophilic substitution (S N 2). Herein, atomistic dynamics of a prototype S N 2@N reaction F - + NH 2 Cl is uncovered employing direct dynamics simulations that show strikingly distinct features from those determined for a S N 2@C congener F - + CH 3 Cl. Indirect scattering is found to prevail, which proceeds predominantly through a hydrogen-bonded F - -HNHCl complex in the reactant entrance channel. This unexpected finding of a pronounced contribution of indirect reaction dynamics, even at a high collision energy, is in strong contrast to a general evolution from indirect to direct dynamics with enhanced energy that characterizes S N 2@C. This result suggests that the relative importance of different atomic-level mechanisms may depend essentially on the interaction potential of reactive encounters and the coupling between inter- and intramolecular modes of the pre-reaction complex. For F - + NH 2 Cl the proton transfer pathway is less competitive than S N 2. A remarkable finding is that the more favorable energetics for NH 2 Cl proton transfer, as compared to that for CH 3 Cl, does not manifest itself in the reaction dynamics. The present work sheds light on the underlying reaction dynamics of S N 2@N, which remain largely unclear compared to well-studied S N 2@C.
NASA Astrophysics Data System (ADS)
Proper, Megan Longo
I present an indirect search for Dark Matter using the High Altitude Water Cherenkov (HAWC) gamma-ray observatory. There is significant evidence for dark matter within the known Universe, and we can set constraints on the dark matter annihilation cross-section using dark matter rich sources. Dwarf spheroidal galaxies (dSphs) are low luminosity galaxies with little to no gas or dust, or recent star formation. In addition, the total mass of a dwarf spheroidal galaxy, as inferred from gravitational effects observed within the galaxy, is many times more than the luminous mass, making them extremely dark matter rich. For these reasons dSphs are prime targets for indirect dark matter searches with gamma rays. Dark matter annihilation cross-section limits are presented for 14 dSphs within the HAWC field of view, as well as a combined limit with all sources. The limits presented here are for dark matter masses ranging from 0.5 TeV to 1000 TeV. At lower dark matter masses, the HAWC-111 limits are not competitive with other gamma-ray experiments, however it will be shown that HAWC is currently dominating in the higher dark matter mass range. The HAWC observatory is a water Cherenkov detector and consists of 300 Water Cherenkov Detectors (WCDs). The detector is located at 4100 m above sea level in the Sierra Negra region of Mexico at latitude 18°59'41" N and longitude 97°18'28" W. Each WCD is instrumented with three 8 inch photomultiplier tubes (PMTs) and one 10 inch high efficiency PMT, anchored to the bottom of a 5 m deep by 7.3 m diameter steel tank. The tank contains a multilayer hermetic plastic bag, called a bladder, which holds 200,000 L of ultra-purified water. I will also present the design, deployment, and operation of a WCD prototype for HAWC built at Colorado State University (CSU). The CSU WCD was the only full-size prototype outside of the HAWC site. It was instrumented with 7 HAWC PMTs and scintillator paddles both under and above the volume of water. In addition, the CSU WCD was equipped with the same laser calibration system that is deployed at the HAWC site, as well as the same electronics and data acquisition system. The WCD prototype served as a testbed for the different subsystems of the HAWC observatory. During the three different installations of the prototype, many aspects of the detector design and performance were tested including: tank construction, bladder installation and performance, PMT installation and performance, roof design, water filtration and filling, muon coincidence measurements and calibration system. The experience gained from the CSU prototype was invaluable to the overall design and installation of the HAWC detector.
NASA Astrophysics Data System (ADS)
Papa, A.; Kettle, P.-R.; Ripiccini, E.; Rutar, G.
2016-07-01
Several scintillating fibre prototypes (single- and double-layers) made of 250 μm multi-clad square fibres coupled to silicon photomultiplier have been studied using electrons, positrons and muons at different energies. Current measurements show promising results: already for a single fibre layer and minimum ionizing particles we obtain a detection efficiency ≥ 95 % (mean collected light/fibre ≈ 8 phe), a timing resolution of 550 ps/fibre and a foreseen spatial resolution < 100 μm, based on the achieved negligible optical cross-talk between fibres (< 1 %). We will also discuss the performances of a double-layer staggered prototype configuration, for which a full detection efficiency (≥ 99 %) has been measured together with a timing resolution of ≈ 400 ps for double hit events.
Hendrikx, Stephan; Kascholke, Christian; Flath, Tobias; Schumann, Dirk; Gressenbuch, Mathias; Schulze, F Peter; Hacker, Michael C; Schulz-Siegmund, Michaela
2016-04-15
We present a series of organic/inorganic hybrid sol-gel derived glasses, made from a tetraethoxysilane-derived silica sol (100% SiO2) and oligovalent organic crosslinkers functionalized with 3-isocyanatopropyltriethoxysilane. The material was susceptible to heat sterilization. The hybrids were processed into pore-interconnected scaffolds by an indirect rapid prototyping method, described here for the first time for sol-gel glass materials. A large panel of polyethylene oxide-derived 2- to 4-armed crosslinkers of molecular weights ranging between 170 and 8000Da were incorporated and their effect on scaffold mechanical properties was investigated. By multiple linear regression, 'organic content' and the 'content of ethylene oxide units in the hybrid' were identified as the main factors that determined compressive strength and modulus, respectively. In general, 3- and 4-armed crosslinkers performed better than linear molecules. Compression tests and cell culture experiments with osteoblast-like SaOS-2 cells showed that macroporous scaffolds can be produced with compressive strengths of up to 33±2MPa and with a pore structure that allows cells to grow deep into the scaffolds and form mineral deposits. Compressive moduli between 27±7MPa and 568±98MPa were obtained depending on the hybrid composition and problems associated with the inherent brittleness of sol-gel glass materials could be overcome. SaOS-2 cells showed cytocompatibility on hybrid glass scaffolds and mineral accumulation started as early as day 7. On day 14, we also found mineral accumulation on control hybrid glass scaffolds without cells, indicating a positive effect of the hybrid glass on mineral accumulation. We produced a hybrid sol-gel glass material with significantly improved mechanical properties towards an application in bone regeneration and processed the material into macroporous scaffolds of controlled architecture by indirect rapid prototyping. We were able to produce macroporous materials of relevant porosity and pore size with compressive moduli, covering the range reported for cancellous bone while an even higher compressive strength was maintained. By multiple linear regression, we identified crosslinker parameters, namely organic content and the content of ethylene oxide units in the hybrids that predominantly determined the mechanics of the hybrid materials. The scaffolds proved to be cytocompatible and induced mineralization in SaOS-2 cells. This provides new insight on the critical parameters for the design of the organic components of covalent hybrid sol-gel glasses. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
X-ray scan detection for cargo integrity
NASA Astrophysics Data System (ADS)
Valencia, Juan; Miller, Steve
2011-04-01
The increase of terrorism and its global impact has made the determination of the contents of cargo containers a necessity. Existing technology allows non-intrusive inspections to determine the contents of a container rapidly and accurately. However, some cargo shipments are exempt from such inspections. Hence, there is a need for a technology that enables rapid and accurate means of detecting whether such containers were non-intrusively inspected. Non-intrusive inspections are most commonly performed utilizing high powered X-ray equipment. The challenge is creating a device that can detect short duration X-ray scans while maintaining a portable, battery powered, low cost, and easy to use platform. The Pacific Northwest National Laboratory (PNNL) has developed a methodology and prototype device focused on this challenge. The prototype, developed by PNNL, is a battery powered electronic device that continuously measures its X-ray and Gamma exposure, calculates the dose equivalent rate, and makes a determination of whether the device has been exposed to the amount of radiation experienced during an X-ray inspection. Once an inspection is detected, the device will record a timestamp of the event and relay the information to authorized personnel via a visual alert, USB connection, and/or wireless communication. The results of this research demonstrate that PNNL's prototype device can be effective at determining whether a container was scanned by X-ray equipment typically used for cargo container inspections. This paper focuses on laboratory measurements and test results acquired with the PNNL prototype device using several X-ray radiation levels.
Caliste 64: detection unit of a spectro imager array for a hard x-ray space telescope
NASA Astrophysics Data System (ADS)
Limousin, O.; Meuris, A.; Lugiez, F.; Gevin, Olivier; Pinsard, F.; Blondel, C.; Le Mer, I.; Delagnes, E.; Vassal, M. C.; Soufflet, F.; Bocage, R.; Penquer, A.; Billot, M.
2017-11-01
In the frame of the hard X-ray Simbol-X observatory, a joint CNES-ASI space mission to be flown in 2014, a prototype of miniature Cd(Zn)Te camera equipped with 64 pixels has been designed. The device, called Caliste 64, is a spectro-imager with high resolution event timetagging capability. Caliste 64 integrates a Cd(Zn)Te semiconductor detector with segmented electrode and its front-end electronics made of 64 independent analog readout channels. This 1 × 1 × 2 cm3 camera, able to detect photons in the range from 2 keV up to 250 keV, is an elementary detection unit juxtaposable on its four sides. Consequently, large detector array can be made assembling a mosaic of Caliste 64 units. Electronics readout module is achieved by stacking four IDeF-X V1.1 ASICs, perpendicular to the detection plane. We achieved good noise performances, with a mean Equivalent Noise Charge of 65 electrons rms over the 64 channels. For the first prototypes, we chose Pt//CdTe//Al/Ti/Au Schottky detectors because of their very low dark current and excellent spectroscopic performances. Recently a Caliste 64 prototype has been also equipped with a 2 mm thick Au//CdZnTe//Au detector. This paper presents the performances of these four prototypes and demonstrates spectral performances better than 1 keV fwhm at 59.54 keV when the samples are moderately cooled down to -10°C.
Preparation of genosensor for detection of specific DNA sequence of the hepatitis B virus
NASA Astrophysics Data System (ADS)
Honorato Castro, Ana C.; França, Erick G.; de Paula, Lucas F.; Soares, Marcia M. C. N.; Goulart, Luiz R.; Madurro, João M.; Brito-Madurro, Ana G.
2014-09-01
An electrochemical genosensor was constructed for detection of specific DNA sequence of the hepatitis B virus, based on graphite electrodes modified with poly(4-aminophenol) and incorporating a specific oligonucleotide probe. The modified electrode containing the probe was evaluated by differential pulse voltammetry, before and after incubation with the complementary oligonucleotide target. Detection was performed by monitoring oxidizable DNA bases (direct detection) or using ethidium bromide as indicator of the hybridization process (indirect detection). The device showed a detection limit for the oligonucleotide target of 2.61 nmol L-1. Indirect detection using ethidium bromide was promising in discriminating mismatches, which is a very desirable attribute for detection of disease-related point mutations. In addition, it was possible to observe differences between hybridized and non-hybridized surfaces by atomic force microscopy.
Qiu, Jun; Wang, Jinhao; Xu, Zhongqi; Liu, Huiqing; Ren, Jie
2017-01-01
The branched-chain amino acids (BCAAs) including leucine (Leu), isoleucine (Ile) and valine (Val) play a pivotal role in the human body. Herein, we developed capillary electrophoresis (CE) coupled with conventional UV detector to quantify underivatized BCAAs in two kinds of sport nutritional supplements. For direct UV detection at 195 nm, the BCAAs (Leu, two enantiomers of Ile and Val) were separated in a background electrolyte (BGE) consisting of 40.0 mmol/L sodium tetraborate, and 40.0 mmol/L β-cyclodextrin (β-CD) at pH 10.2. In addition, the indirect UV detection at 264 nm was achieved in a BGE of 2.0 mmol/L Na2HPO4, 10.0 mmol/L p-aminosalicylic acid (PAS) as UV absorbing probe, and 40.0 mmol/L β-CD at pH 12.2. The β-CD significantly benefited the isomeric separation of Leu, L- and D-Ile. The optimal conditions allowed the LODs (limit of detections) of direct and indirect UV absorption detection to be tens μmol/L level, which was comparable to the reported CE inline derivatization method. The RSDs (relative standard deviations) of migration time and peak area were less than 0.91% and 3.66% (n = 6). Finally, CE with indirect UV detection method was applied for the quantitation of BCAAs in two commercial sport nutritional supplements, and good recovery and precision were obtained. Such simple CE method without tedious derivatization process is feasible of quality control and efficacy evaluation of the supplemental proteins.
Liu, Huiqing; Ren, Jie
2017-01-01
The branched-chain amino acids (BCAAs) including leucine (Leu), isoleucine (Ile) and valine (Val) play a pivotal role in the human body. Herein, we developed capillary electrophoresis (CE) coupled with conventional UV detector to quantify underivatized BCAAs in two kinds of sport nutritional supplements. For direct UV detection at 195 nm, the BCAAs (Leu, two enantiomers of Ile and Val) were separated in a background electrolyte (BGE) consisting of 40.0 mmol/L sodium tetraborate, and 40.0 mmol/L β-cyclodextrin (β-CD) at pH 10.2. In addition, the indirect UV detection at 264 nm was achieved in a BGE of 2.0 mmol/L Na2HPO4, 10.0 mmol/L p-aminosalicylic acid (PAS) as UV absorbing probe, and 40.0 mmol/L β-CD at pH 12.2. The β-CD significantly benefited the isomeric separation of Leu, L- and D-Ile. The optimal conditions allowed the LODs (limit of detections) of direct and indirect UV absorption detection to be tens μmol/L level, which was comparable to the reported CE inline derivatization method. The RSDs (relative standard deviations) of migration time and peak area were less than 0.91% and 3.66% (n = 6). Finally, CE with indirect UV detection method was applied for the quantitation of BCAAs in two commercial sport nutritional supplements, and good recovery and precision were obtained. Such simple CE method without tedious derivatization process is feasible of quality control and efficacy evaluation of the supplemental proteins. PMID:28640882
Varden, Lara; Smith, Britannia; Bou-Abdallah, Fadi
2017-01-01
Capillary zone electrophoresis (CZE) is a sensitive and rapid technique used for determining traces of inorganic and organic anions in potable, natural, and wastewaters. Here, CZE with indirect UV-diode array detection (CZE-DAD) was employed with a background electrolyte system comprising of an Agilent Technologies proprietary basic anion buffer at pH 12.0 and a forensic anion detection method. The limits of detection (LOD) for this method ranged between 3 and 5 ppm and involved hydrodynamic injection of 50 mbar for 6 s with a negative polarity separation voltage of −30 kV at 30°C, a detection wavelength of 350 nm and indirect reference of 275 nm. Fourteen different anions were checked for in the water samples that were examined and included bromide, chloride, thiosulfate, nitrate, nitrite, sulfate, azide, carbonate, fluoride, arsenate, phosphate, acetate, lactate, and silicate. The water samples were collected from Northern New York towns and the Raquette River water system, the third longest river in New York State and the largest watershed of the central and western Adirondacks. The concentrations detected for these anions ranged from <5.0 ppm to 260 ppm. PMID:29057145
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kobayshi, Takeshi; Nishiyama, Yusuke; Pruski, Marek
The main focus of this chapter is to address experimental strategies on the subject by providing a hands-on guide to fast MAS experiments, with a particular focus on indirect detection. Although our experience is limited to our respective laboratories in Ames and Yokohama, we hope that our descriptions of experimental setups and optimization procedures are sufficiently general to be applicable to all modern instruments. The chapter is organized as follows. Section 2 below introduces briefly the fast MAS technology and its main advantages. In Section 3, we describe the hardware associated with this remarkable technology and provide practical advices onmore » its use, including procedures for loading and unloading the samples, maintaining the probe, reducing t 1 noise, etc. In Section 4, we describe the principles and hands-on aspects of experiments involving the indirect detection of spin-1/2 and 14N nuclei« less
Indirect measures as a signal for evaluative change.
Perugini, Marco; Richetin, Juliette; Zogmaister, Cristina
2014-01-01
Implicit and explicit attitudes can be changed by using evaluative learning procedures. In this contribution we investigated an asymmetric effect of order of administration of indirect and direct measures on the detection of evaluative change: A change in explicit attitudes is more likely detected if they are measured after implicit attitudes, whereas these latter change regardless of the order. This effect was demonstrated in two studies (n=270; n=138) using the self-referencing task whereas it was not found in a third study (n=151) that used a supraliminal sequential evaluative conditioning paradigm. In all studies evaluative change was present only for contingency aware participants. We discuss a potential explanation underlying the order of measure effect entailing that, in some circumstances, an indirect measure is not only a measure but also a signal that can be detected through self-perception processes and further elaborated at the propositional level.
Lightweight autonomous chemical identification system (LACIS)
NASA Astrophysics Data System (ADS)
Lozos, George; Lin, Hai; Burch, Timothy
2012-06-01
Smiths Detection and Intelligent Optical Systems have developed prototypes for the Lightweight Autonomous Chemical Identification System (LACIS) for the US Department of Homeland Security. LACIS is to be a handheld detection system for Chemical Warfare Agents (CWAs) and Toxic Industrial Chemicals (TICs). LACIS is designed to have a low limit of detection and rapid response time for use by emergency responders and could allow determination of areas having dangerous concentration levels and if protective garments will be required. Procedures for protection of responders from hazardous materials incidents require the use of protective equipment until such time as the hazard can be assessed. Such accurate analysis can accelerate operations and increase effectiveness. LACIS is to be an improved point detector employing novel CBRNE detection modalities that includes a militaryproven ruggedized ion mobility spectrometer (IMS) with an array of electro-resistive sensors to extend the range of chemical threats detected in a single device. It uses a novel sensor data fusion and threat classification architecture to interpret the independent sensor responses and provide robust detection at low levels in complex backgrounds with minimal false alarms. The performance of LACIS prototypes have been characterized in independent third party laboratory tests at the Battelle Memorial Institute (BMI, Columbus, OH) and indoor and outdoor field tests at the Nevada National Security Site (NNSS). LACIS prototypes will be entering operational assessment by key government emergency response groups to determine its capabilities versus requirements.
Diagnostic performance of indirect MR arthrography for the diagnosis of rotator cuff tears at 3.0 T.
Lee, Ji Hyun; Yoon, Young Cheol; Jee, Sukkyung
2015-06-01
Indirect magnetic resonance (MR) arthrography is a non-invasive method for shoulder imaging. However, there are no studies that have examined the diagnostic performance of indirect MR arthrography for the diagnosis of rotator cuff tears in a large patient population. To assess the diagnostic performance of indirect fast spin-echo (FSE) MR arthrography for the diagnosis of rotator cuff tears at 3.0 T. A total of 149 patients who had undergone indirect shoulder MR arthrography followed by arthroscopic surgery were enrolled in this retrospective study. Two musculoskeletal radiologists evaluated images from each patient for the presence of supraspinatus-infraspinatus (SSP-ISP) or subscapularis (SSC) tendon tears. Using the arthroscopic findings as the reference standard, the overall diagnostic performance and detection rates for SSP-ISP and SSC tendon tears were calculated. The sensitivity, specificity, and accuracy of readers I and II for the diagnosis of SSP-ISP tendon tears were 94% and 95%, 89% and 85%, and 93% and 93%, respectively. The sensitivity of imaging for detection of SSP-ISP tendon tears by readers I and II were 100% and 100% for full-thickness tears and 84% and 86% for partial-thickness tears, respectively. The sensitivity, specificity, and accuracy of readers I and II for the diagnosis of SSC tendon tears were 80% and 76%, 89% and 93%, and 85% and 85%, respectively. Indirect MR arthrography is useful for the detection of SSP-ISP and SSC tendon tears. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Target Detection Using an AOTF Hyperspectral Imager
NASA Technical Reports Server (NTRS)
Cheng, L-J.; Mahoney, J.; Reyes, F.; Suiter, H.
1994-01-01
This paper reports results of a recent field experiment using a prototype system to evaluate the acousto-optic tunable filter polarimetric hyperspectral imaging technology for target detection applications.
On-line high-speed rail defect detection : part II.
DOT National Transportation Integrated Search
2012-03-01
The objectives of this project were (1) to improve the defect detection reliability and (2) to improve the inspection speed of conventional rail defect detection methods. The prototype developed in this work uses noncontact transducers, ultrasonic gu...
Indirect estimation of signal-dependent noise with nonadaptive heterogeneous samples.
Azzari, Lucio; Foi, Alessandro
2014-08-01
We consider the estimation of signal-dependent noise from a single image. Unlike conventional algorithms that build a scatterplot of local mean-variance pairs from either small or adaptively selected homogeneous data samples, our proposed approach relies on arbitrarily large patches of heterogeneous data extracted at random from the image. We demonstrate the feasibility of our approach through an extensive theoretical analysis based on mixture of Gaussian distributions. A prototype algorithm is also developed in order to validate the approach on simulated data as well as on real camera raw images.
Bigot, Alexandre; Soulez, Gilles; Martel, Sylvain
2017-01-01
An injector equipped with a bead capture and a bead detection system is presented. In the context of magnetic resonance navigation (MRN), in which MRI gradients are used to steer intravascular therapeutic carriers, fast and reliable injection is essential. In this paper, we present a prototype of injector to control and to detect the release of magnetic beads. The injector relies on two distinct subsystems: (1) the capture subsystem, which creates local magnetic force to stop the flow of magnetic beads; and (2) the detection subsystem, which detects flowing beads and generates a trigger signal to start MRI gradient pulses. Both systems rely on small microcoils wound on the tubing. Five-turn microcoils show the best compromise between size and performance. Less than 5 mW of power is required to capture 0.8-mm beads moving in a flow above 5 mL min -1 or when a gradient above 200 mT m -1 is applied. The detection system is not sensitive to noise and detects every 0.8-mm bead in flow rates up to 14 mL m -1 . The prototype of injector shows performance above the requirements inherent to magnetic resonance navigation. This system is a step toward in vivo multibifurcation MRN. Magn Reson Med 77:444-452, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
García-Diego, Fernando-Juan; Bravo, José María; Pérez-Miralles, Juan; Estrada, Héctor; Fernández-Navajas, Angel
2012-01-01
Non-destructive methods are of great interest for the analysis of cultural heritage. Among the different possible techniques, this paper presents a low cost prototype based on the emission and reception of airborne ultrasound without direct contact with the test specimen. We successfully performed a method test for the detection of brick joints under a XV th century Renaissance fresco of the Metropolitan Cathedral of the city of Valencia (Spain). Both laboratory and in situ results are in agreement. Using this prototype system, an early moisture detection system has been installed in the dome that supports the fresco. The result is encouraging and opens interesting prospects for future research.
Culka, Adam; Osterrothová, Kateřina; Hutchinson, Ian; Ingley, Richard; McHugh, Melissa; Oren, Aharon; Edwards, Howell G M; Jehlička, Jan
2014-12-13
A prototype instrument, under development at the University of Leicester, for the future European Space Agency (ESA) ExoMars mission, was used for the analysis of microbial pigments within a stratified gypsum crust from a hypersaline saltern evaporation pond at Eilat (Israel). Additionally, the same samples were analysed using a miniaturized Raman spectrometer, featuring the same 532 nm excitation. The differences in the position of the specific bands, attributed to carotenoid pigments from different coloured layers, were minor when analysed by the ESA prototype instrument; therefore, making it difficult to distinguish among the different pigments. The portable Delta Nu Advantage instrument allowed for the discrimination of microbial carotenoids from the orange/green and purple layers. The purpose of this study was to complement previous laboratory results with new data and experience with portable or handheld Raman systems, even with a dedicated prototype Raman system for the exploration of Mars. The latter is equipped with an excitation wavelength falling within the carotenoid polyene resonance region. The ESA prototype Raman instrument detected the carotenoid pigments (biomarkers) with ease, although further detailed distinctions among them were not achieved. © 2014 The Author(s) Published by the Royal Society. All rights reserved.
NASA Astrophysics Data System (ADS)
Charpak, G.; Benaben, P.; Breuil, P.; Martinengo, P.; Nappi, E.; Peskov, V.
2011-02-01
We have developed and successfully tested two prototypes of detectors of dangerous gases based on wire-type counters operating in air in avalanche mode: one is for radon (Rn) detection whereas the other one is for the detection of gases with an ionization potential less than the air components. Due to the operation in pulse counting mode these prototypes have sensitivities comparable to (in the case of the Rn detector) or much higher than (in the case of the detector for low ionization gases) the best commercial devices currently available on the market. We believe that due to their high sensitivity, simplicity and low cost such new detectors will find massive applications. One of them, discussed in this paper, could be the on-line monitoring of Rn for the prediction of earthquakes.
The waning of the WIMP? A review of models, searches, and constraints
NASA Astrophysics Data System (ADS)
Arcadi, Giorgio; Dutra, Maíra; Ghosh, Pradipta; Lindner, Manfred; Mambrini, Yann; Pierre, Mathias; Profumo, Stefano; Queiroz, Farinaldo S.
2018-03-01
Weakly Interacting Massive Particles (WIMPs) are among the best-motivated dark matter candidates. No conclusive signal, despite an extensive search program that combines, often in a complementary way, direct, indirect, and collider probes, has been detected so far. This situation might change in near future due to the advent of one/multi-TON Direct Detection experiments. We thus, find it timely to provide a review of the WIMP paradigm with focus on a few models which can be probed at best by these facilities. Collider and Indirect Detection, nevertheless, will not be neglected when they represent a complementary probe.
Chao, Chien-Chung; Zhangm, Zhiwen; Weissenberger, Giulia; Chen, Hua-Wei; Ching, Wei-Mei
2017-03-01
Scrub typhus (ST) is an infection caused by Orientia tsutsugamushi. Historically, ST was ranked as the second most important arthropod-borne medical problem only behind malaria during World War II and the Vietnam War. The disease occurs mainly in Southeast Asia and has been shown to emerge and reemerge in new areas, implying the increased risk for U.S. military and civilian personnel deployed to these regions. ST can effectively be treated by doxycycline provided the diagnosis is made early, before the development of severe complications. Scrub Typhus Detect is a lateral flow rapid test based on a mixture of recombinant 56-kDa antigens with broad reactivity. The performance of this prototype product was evaluated against indirect immunofluorescence assay, the serological gold standard. Using 249 prospectively collected samples from Thailand, the sensitivity and specificity for IgM was found to be 100% and 92%, respectively, suggesting a high potential of this product for clinical use. This product will provide a user friendly, rapid, and accurate diagnosis of ST for clinicians to provide timely and accurate treatments of deployed personnel. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.
USDA-ARS?s Scientific Manuscript database
An electrochemical prototype (ECP) was designed and validated to determine NaCl electrical variables [volt (V), ampere (A), resistance (R), and power (P)] and its application for detection of possible adulteration in fresh cheeses. The ECP circuit consisted of two electrodes, aluminum (anode) and c...
Ultrasonic technique for detection of liquids in copper tubing process lines
NASA Astrophysics Data System (ADS)
Dudley, W. A.
1980-10-01
An ultrasonic pulse-echo method developed for semiquantitative measurement of liquid levels in copper tubing is described. This ultrasonic approach is of particular value when used as a pre-maintenance diagnostic tool in repairing process lines containing hazardous liquids. Performance tests show that water and similar liquids can be directly detected to fill levels as low as 1/16 in. For water fills below 1/16 in., direct level detection is impractical because of signal resolution limitations. However, this fill condition is indirectly measurable and is detected by the effect of observed degradation of the adjacent wall echo pattern. Fill conditions for liquids associated with high sound attenuation such as oil can be indirectly determined.
The indirect fluorescent antibody technique as a method for detecting antibodies in aborted fetuses.
Miller, R B; Wilkie, B N
1979-01-01
In this investigation the indirect fluorescent antibody technique was used to titrate antibodies in bovine sera to parainfluenza 3, infectious bovine rhinotracheitis virus and bovine viral diarrhea virus. These results were compared to those determined on the same samples by hemagglutination inhibition for parainfluenza 3 virus and serum neutralization for bovine virus diarrhea and infectious bovine rhinotracheitis virus. The results of the serological methods agreed closely. The indirect fluorescent antibody technique is a rapid and sensitive method for detecting antibodies and the procedure lends itself to use in diagnostic laboratories. In addition to the above viruses the presence or absence of antibodies to bovine coronavirus and bovine adenovirus 3 were determined by the indirect fluorescent antibody technique in thoracic fluids from 100 aborted fetuses and 50 nonaborted fetuses. Results on these samples were not compared to hemagglutination inhibition or serum neutralization as the condition of fluid samples from aborted fetuses renders interpretation of such tests unreliable. Antibodies to one or more viruses were detected in 30 of the 100 aborted fetuses and in seven of the 50 nonaborted fetuses. Antibodies to more than one agent were detected in eleven of the 100 aborted and in one of the 50 nonaborted fetuses. Reasons for this occurrence and application of the test in determination of causes of abortion are discussed. PMID:226243
Automated Content Detection for Cassini Images
NASA Astrophysics Data System (ADS)
Stanboli, A.; Bue, B.; Wagstaff, K.; Altinok, A.
2017-06-01
NASA missions generate numerous images ever organized in increasingly large archives. Image archives are currently not searchable by image content. We present an automated content detection prototype that can enable content search.
A Portable, Inexpensive, Nonmydriatic Fundus Camera Based on the Raspberry Pi® Computer.
Shen, Bailey Y; Mukai, Shizuo
2017-01-01
Purpose. Nonmydriatic fundus cameras allow retinal photography without pharmacologic dilation of the pupil. However, currently available nonmydriatic fundus cameras are bulky, not portable, and expensive. Taking advantage of recent advances in mobile technology, we sought to create a nonmydriatic fundus camera that was affordable and could be carried in a white coat pocket. Methods. We built a point-and-shoot prototype camera using a Raspberry Pi computer, an infrared-sensitive camera board, a dual infrared and white light light-emitting diode, a battery, a 5-inch touchscreen liquid crystal display, and a disposable 20-diopter condensing lens. Our prototype camera was based on indirect ophthalmoscopy with both infrared and white lights. Results. The prototype camera measured 133mm × 91mm × 45mm and weighed 386 grams. The total cost of the components, including the disposable lens, was $185.20. The camera was able to obtain good-quality fundus images without pharmacologic dilation of the pupils. Conclusion. A fully functional, inexpensive, handheld, nonmydriatic fundus camera can be easily assembled from a relatively small number of components. With modest improvements, such a camera could be useful for a variety of healthcare professionals, particularly those who work in settings where a traditional table-mounted nonmydriatic fundus camera would be inconvenient.
A Portable, Inexpensive, Nonmydriatic Fundus Camera Based on the Raspberry Pi® Computer
Shen, Bailey Y.
2017-01-01
Purpose. Nonmydriatic fundus cameras allow retinal photography without pharmacologic dilation of the pupil. However, currently available nonmydriatic fundus cameras are bulky, not portable, and expensive. Taking advantage of recent advances in mobile technology, we sought to create a nonmydriatic fundus camera that was affordable and could be carried in a white coat pocket. Methods. We built a point-and-shoot prototype camera using a Raspberry Pi computer, an infrared-sensitive camera board, a dual infrared and white light light-emitting diode, a battery, a 5-inch touchscreen liquid crystal display, and a disposable 20-diopter condensing lens. Our prototype camera was based on indirect ophthalmoscopy with both infrared and white lights. Results. The prototype camera measured 133mm × 91mm × 45mm and weighed 386 grams. The total cost of the components, including the disposable lens, was $185.20. The camera was able to obtain good-quality fundus images without pharmacologic dilation of the pupils. Conclusion. A fully functional, inexpensive, handheld, nonmydriatic fundus camera can be easily assembled from a relatively small number of components. With modest improvements, such a camera could be useful for a variety of healthcare professionals, particularly those who work in settings where a traditional table-mounted nonmydriatic fundus camera would be inconvenient. PMID:28396802
Electronic Tongue for Quantitation of Contaminants in Water
NASA Technical Reports Server (NTRS)
Buehler, Marlin; Kuhlman, Gregory
2004-01-01
An assembly of sensors, denoted an electronic tongue, is undergoing development as a prototype of compact devices for use in measuring concentrations of contaminants in water. Thus far, the electronic tongue has been tested on ions of Cu, Zn, Pb, and Fe and shown to respond to concentrations as low as about 10 parts per million. This electronic tongue is expected to be capable of measuring concentrations of other metal ions and organic compounds. Potential uses for electronic tongues include monitoring the chemical quality of water in a variety of natural, industrial, and laboratory settings; detecting micro-organisms indirectly by measuring microbially influenced corrosion; and characterizing compounds of interest to the pharmaceutical and food industries. This version of the electronic tongue includes a heater, a temperature sensor, an array of ion-specific electrodes, an oxidation/ reduction sensor pair, an electrical-conductivity sensor, and an array of galvanic cells, all on one compact ceramic substrate. Special-purpose electronic excitation and readout circuitry for the sensors has also been constructed. The main advantage of the electronic tongue, relative to electrodes of this type used traditionally to assess water quality, is extreme ruggedness. The types of measurements that can be performed by use of the sensors on the electronic tongue are quite varied. The best combination of types of measurements for a given application depends on the specific contaminants that one seeks to detect. Experimental studies to identify such combinations were in progress at the time of reporting the information for this article.
Clinical Evaluation of a Prototype Underwear Designed to Detect Urine Leakage From Continence Pads.
Long, Adele; Edwards, Julia; Worthington, Joanna; Cotterill, Nikki; Weir, Iain; Drake, Marcus J; van den Heuvel, Eleanor
2015-01-01
We evaluated the performance of prototype underwear designed to detect urine leakage from continence pads, their acceptability to users, and their effect on health-related quality of life and psychosocial factors. Prototype product evaluation. Participants were 81 women with an average age of 67 years (range, 32-98 years) recruited between October 2010 and February 2012 from outpatient clinics, general practice surgeries, community continence services, and through charities and networks. The TACT3 project developed and manufactured a prototype undergarment designed to alert the wearer to a pad leak before it reaches outer clothing or furniture. The study was conducted in 2 stages: a pilot/feasibility study to assess general performance and a larger study to measure performance, acceptability to users, health-related quality of life, and psychosocial impact. Participants were asked to wear the prototype underwear for a period of 2 weeks, keeping a daily diary of leakage events for the first 7 days. They also completed validated instruments measuring lower urinary tract symptoms, health-related quality of life, and psychosocial impact. On average, 86% of the time participants were alerted to pad leakage events. More than 90% thought the prototype underwear was "good" or "OK" and that it would or could give them more confidence. Mean scores for the International Consultation on Incontinence Questionnaire-Urinary Incontinence Short Form indicated no change in the level of symptoms reported before or after the intervention, and no significant changes in health-related quality of life status occurred, except improvement in for travel restrictions. Evaluation via the Psychosocial Impact of Assistive Devices Scale also indicated a positive impact. The prototype underwear evaluated in this study was effective and acceptable for 5 out of every 10 wearers. Findings also suggest that the prototype underwear is suitable for women of all ages, dress sizes, and continence severity.
Status of the Prototype Pulsed Photonuclear Assessment (PPA) Inspection System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prototype Photonuclear Inspection Technoloby - An
Prototype Photonuclear Inspection Technology – An Integrated Systems Approach* James L. Jonesa, Daren R. Normana, Kevin J. Haskella, James W. Sterbentza, Woo Y. Yoona, Scott M. Watsona, James T. Johnsona, John M. Zabriskiea, Calvin E. Mossb, Frank Harmonc a – Idaho National Laboratory, P.O. Box 1625-2802, Idaho Falls, Idaho 83415-2802 b – Los Alamos National Laboratory, P.O. Box 1663, MS B228, Los Alamos, New Mexico, 87585 c – Idaho State University, 1500 Alvin Ricken Dr., Pocatello, Idaho 83201 Active interrogation technologies are being pursued in order to address many of today’s challenging inspection requirements related to both nuclear and non-nuclearmore » material detection. The Idaho National Laboratory, along with the Los Alamos National Laboratory and the Idaho State University’s Idaho Accelerator Center, continue to develop electron accelerator-based, photonuclear inspection technologies for the detection of shielded nuclear material within air-, rail-, and especially, maritime-cargo containers. This paper presents an overview and status of the prototype Pulsed Photonuclear Assessment (PPA) inspection system and its ability to detect shielded nuclear material by focusing on the integration of three major detection system components: delayed neutron measurement, delayed gamma-ray measurements, and a transmission, gray-scale mapping for shield material detection. Areas of future development and advancement within each detection component will be presented. *Supported in part by the Department of Homeland Security under DOE-ID Contract Number DE-AC07-99ID13727. POC: James L. Jones, 208-526-1730« less
The evaluation of phasemeter prototype performance for the space gravitational waves detection.
Liu, He-Shan; Dong, Yu-Hui; Li, Yu-Qiong; Luo, Zi-Ren; Jin, Gang
2014-02-01
Heterodyne laser interferometry is considered as the most promising readout scheme for future space gravitational wave detection missions, in which the gravitational wave signals disguise as small phase variances within the heterodyne beat note. This makes the phasemeter, which extracts the phase information from the beat note, the key device to this system. In this paper, a prototype of phasemeter based on digital phase-locked loop technology is developed, and the major noise sources which may contribute to the noise spectra density are analyzed in detail. Two experiments are also carried out to evaluate the performance of the phasemeter prototype. The results show that the sensitivity is achieved 2π μrad/√Hz in the frequency range of 0.04 Hz-10 Hz. Due to the effect of thermal drift, the noise obviously increases with the frequencies down to 0.1 mHz.
The evaluation of phasemeter prototype performance for the space gravitational waves detection
NASA Astrophysics Data System (ADS)
Liu, He-Shan; Dong, Yu-Hui; Li, Yu-Qiong; Luo, Zi-Ren; Jin, Gang
2014-02-01
Heterodyne laser interferometry is considered as the most promising readout scheme for future space gravitational wave detection missions, in which the gravitational wave signals disguise as small phase variances within the heterodyne beat note. This makes the phasemeter, which extracts the phase information from the beat note, the key device to this system. In this paper, a prototype of phasemeter based on digital phase-locked loop technology is developed, and the major noise sources which may contribute to the noise spectra density are analyzed in detail. Two experiments are also carried out to evaluate the performance of the phasemeter prototype. The results show that the sensitivity is achieved 2π μrad/√Hz in the frequency range of 0.04 Hz-10 Hz. Due to the effect of thermal drift, the noise obviously increases with the frequencies down to 0.1 mHz.
Prototype Compton imager for special nuclear material
NASA Astrophysics Data System (ADS)
Wulf, Eric A.; Phlips, Bernard F.; Kurfess, James D.; Novikova, Elena I.; Fitzgerald, Carrie
2006-05-01
Compton imagers offer a method for passive detection of nuclear material over background radiation. A prototype Compton imager has been constructed using 8 layers of silicon detectors. Each layer consists of a 2×2 array of 2 mm thick cross-strip double-sided silicon detectors with active areas of 5.7 × 5.7 cm2 and 64 strips per side. The detectors are daisy-chained together in the array so that only 256 channels of electronics are needed to read-out each layer of the instrument. This imager is a prototype for a large, high-efficiency Compton imager that will meet operational requirements of Homeland Security for detection of shielded uranium. The instrument can differentiate between different radioisotopes using the reconstructed gamma-ray energy and can also show the location of the emissions with respect to the detector location. Results from the current instrument as well as simulations of the next generation instrument are presented.
NASA Astrophysics Data System (ADS)
Bhunia, Amit; Singh, Mohit Kumar; Galvão Gobato, Y.; Henini, Mohamed; Datta, Shouvik
2018-01-01
We investigated excitonic absorptions in a GaAs/AlAs/GaAs single barrier heterostructure using both photocapacitance and photocurrent spectroscopies at room temperature. Photocapacitance spectra show well defined resonance peaks of indirect excitons formed around the Γ-AlAs barrier. Unlike DC-photocurrent spectra, frequency dependent photocapacitance spectra interestingly red shift, sharpen up, and then decrease with increasing tunneling at higher biases. Such dissimilarities clearly point out that different exciton dynamics govern these two spectral measurements. We also argue why such quantum confined dipoles of indirect excitons can have thermodynamically finite probabilities to survive even at room temperature. Finally, our observations demonstrate that the photocapacitance technique, which was seldom used to detect excitons in the past, is useful for selective detection and experimental tuning of relatively small numbers (˜1011/cm2) of photo-generated indirect excitons having large effective dipole moments in this type of quasi-two dimensional heterostructures.
A false start in the race against doping in sport: concerns with cycling's biological passport.
Hailey, Nicholas
2011-11-01
Professional cycling has suffered from a number of doping scandals. The sport's governing bodies have responded by implementing an aggressive new antidoping program known as the biological passport. Cycling's biological passport marks a departure from traditional antidoping efforts, which have focused on directly detecting prohibited substances in a cyclist's system. Instead, the biological passport tracks biological variables in a cyclist's blood and urine over time, monitoring for fluctuations that are thought to indirectly reveal the effects of doping. Although this method of indirect detection is promising, it also raises serious legal and scientific concerns. Since its introduction, the cycling community has debated the reliability of indirect biological-passport evidence and the clarity, consistency, and transparency of its use in proving doping violations. Such uncertainty undermines the legitimacy of finding cyclists guilty of doping based on this indirect evidence alone. Antidoping authorities should address these important concerns before continuing to pursue doping sanctions against cyclists solely on the basis of their biological passports.
Hallbeck, M Susan; Koneczny, Sonja; Smith, Justine
2009-01-01
Controls for most technologies, including medical devices, are becoming increasingly complex, difficult to intuitively understand and don't necessarily follow population stereotypes. The resulting delays and errors are unacceptable when seconds can mean the difference between life and death. In this study participants were asked to "control" a system using a paper prototype (color photographs of controls) and then with a higher fidelity prototype of the same physical controls to determine performance differences among ethnicities and genders. No ethnic nor gender differences were found, and the comparison of paper versus higher fidelity prototypes also showed no significant differences. Thus, paper prototypes can be employed as an early device design usability tool to illustrate stereotype violations long before the first physical prototype. This will not only save money in the development and design processes, but also makes sure that even the most complex devices are intuitively understandable and operable for their basic functions.
García-Diego, Fernando-Juan; Bravo, José María; Pérez-Miralles, Juan; Estrada, Héctor; Fernández-Navajas, Angel
2012-01-01
Non-destructive methods are of great interest for the analysis of cultural heritage. Among the different possible techniques, this paper presents a low cost prototype based on the emission and reception of airborne ultrasound without direct contact with the test specimen. We successfully performed a method test for the detection of brick joints under a XVth century Renaissance fresco of the Metropolitan Cathedral of the city of Valencia (Spain). Both laboratory and in situ results are in agreement. Using this prototype system, an early moisture detection system has been installed in the dome that supports the fresco. The result is encouraging and opens interesting prospects for future research. PMID:22438711
Design of short-range terahertz wave passive detecting system
NASA Astrophysics Data System (ADS)
Zhang, Chao; Lou, Guowei; Zhu, Li; Qian, Songsong; Li, Ting
2016-09-01
Based on the study of radiation and transmission characteristics on THz waveband, a short-range passive detecting system is designed. The scheme originated from microwave passive detecting system. A prototype was developed following the design of key components including antennas and a harmonic mixer. The system operated at 0.36 THz. A dual-beam Cassegrain antenna was adopted for receiving signals which radiated by object and background. Local oscillator signal was generated by frequency multiplication. Harmonic mixing is adopted for reducing local oscillator signal frequency required by half. Superheterodyne technology is employed for signal acquisition. The system implemented easily. Tests and measurements were taken, which showed that the scheme was feasible and the performance of the prototype system met the design requirements.
Eddy Current System for Material Inspection and Flaw Visualization
NASA Technical Reports Server (NTRS)
Bachnak, R.; King, S.; Maeger, W.; Nguyen, T.
2007-01-01
Eddy current methods have been successfully used in a variety of non-destructive evaluation applications including detection of cracks, measurements of material thickness, determining metal thinning due to corrosion, measurements of coating thickness, determining electrical conductivity, identification of materials, and detection of corrosion in heat exchanger tubes. This paper describes the development of an eddy current prototype that combines positional and eddy-current data to produce a C-scan of tested material. The preliminary system consists of an eddy current probe, a position tracking mechanism, and basic data visualization capability. Initial test results of the prototype are presented in this paper.
Sample size requirements for indirect association studies of gene-environment interactions (G x E).
Hein, Rebecca; Beckmann, Lars; Chang-Claude, Jenny
2008-04-01
Association studies accounting for gene-environment interactions (G x E) may be useful for detecting genetic effects. Although current technology enables very dense marker spacing in genetic association studies, the true disease variants may not be genotyped. Thus, causal genes are searched for by indirect association using genetic markers in linkage disequilibrium (LD) with the true disease variants. Sample sizes needed to detect G x E effects in indirect case-control association studies depend on the true genetic main effects, disease allele frequencies, whether marker and disease allele frequencies match, LD between loci, main effects and prevalence of environmental exposures, and the magnitude of interactions. We explored variables influencing sample sizes needed to detect G x E, compared these sample sizes with those required to detect genetic marginal effects, and provide an algorithm for power and sample size estimations. Required sample sizes may be heavily inflated if LD between marker and disease loci decreases. More than 10,000 case-control pairs may be required to detect G x E. However, given weak true genetic main effects, moderate prevalence of environmental exposures, as well as strong interactions, G x E effects may be detected with smaller sample sizes than those needed for the detection of genetic marginal effects. Moreover, in this scenario, rare disease variants may only be detectable when G x E is included in the analyses. Thus, the analysis of G x E appears to be an attractive option for the detection of weak genetic main effects of rare variants that may not be detectable in the analysis of genetic marginal effects only.
Heleg-Shabtai, Vered; Gratziany, Natzach; Liron, Zvi
2006-05-01
The application of indirect LIF (IDLIF) technique for on-chip electrophoretic separation and detection of the nerve agent O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothiolate (VX) and its major phosphonic degradation products, ethyl methylphosphonic acid (EMPA) and methylphosphonic acid (MPA) was demonstrated. Separation and detection of MPA degradation products of VX and the nerve agent isopropyl methylphosphonofluoridate (GB) are presented. The negatively charged dye eosin was found to be a good fluorescent marker for both the negatively charged phosphonic acids and the positively charged VX, and was chosen as the IDLIF visualization fluorescent dye. Separation and detection of VX, EMPA, and MPA in a simple-cross microchip were completed within less than a minute, and consumed only a 50 pL sample volume. A characteristic system peak that appeared in all IDLIF electropherograms served as an internal standard that increased the reliability of peak identification. The negative peak of both VX and the MPAs is in agreement with indirect detection theory and with previous reports in the literature. The LOD of VX and EMPA by IDLIF was 30 and 37 microM, respectively. Despite the fact that the detection sensitivity is relatively low, the rapid simultaneous on-chip analysis of both VX and its degradation products as well as the separation and detection of the MPA degradation products of both VX and GB, increases detection reliability and may present a choice when sensitivity is not critical compared with speed and simplicity of the assay.
A full Monte Carlo simulation of the YAP-PEM prototype for breast tumor detection
NASA Astrophysics Data System (ADS)
Motta, A.; Righi, S.; Del Guerra, A.; Belcari, N.; Vaiano, A.; De Domenico, G.; Zavattini, G.; Campanini, R.; Lanconelli, N.; Riccardi, A.
2004-07-01
A prototype for Positron Emission Mammography, the YAP-PEM, is under development within a collaboration of the Italian Universities of Pisa, Ferrara, and Bologna. The aim is to detect breast lesions, with dimensions of 5 mm in diameter, and with a specific activity ratio of 10:1 between the cancer and breast tissue. The YAP-PEM is composed of two stationary detection heads of 6×6 cm 2, composed of a matrix of 30×30 YAP:Ce finger crystals of 2×2×30 mm 3 each. The EGSnrc Monte Carlo code has been used to simulate several characteristics of the prototype. A fast EM algorithm has been adapted to reconstruct all of the collected lines of flight, also at large incidence angles, by achieving 3D positioning capability of the lesion in the FOV. The role of the breast compression has been studied. The performed study shows that a 5 mm diameter tumor of 37 kBq/cm 3 (1 μCi/cm 3), embedded in active breast tissue with 10:1 tumor/background specific activity ratio, is detected in 10 min with a Signal-to-Noise Ratio of 8.7±1.0. Two hot lesions in the active breast phantom are clearly visible in the reconstructed image.
Towards the final word on neutralino dark matter
NASA Astrophysics Data System (ADS)
Bramante, Joseph; Desai, Nishita; Fox, Patrick; Martin, Adam; Ostdiek, Bryan; Plehn, Tilman
2016-03-01
We present a complete phenomenological prospectus for thermal relic neutralinos. Including Sommerfeld enhancements to relic abundance and halo annihilation calculations, we obtain direct, indirect, and collider discovery prospects for all neutralinos with mass parameters M1 , M2 , |μ |<4 TeV , which freeze out to the observed dark matter abundance, with scalar superpartners decoupled. Much of the relic neutralino sector will be uncovered by the direct detection experiments Xenon1T and LZ, as well as indirect detection with Cerenkov Telescope Array. We emphasize that thermal relic Higgsinos will be found by next-generation direct detection experiments, so long as M1 ,2<4 TeV . Charged tracks at a 100 TeV hadron collider complement indirect searches for relic winos. Thermal relic bino-winos still evade all planned experiments, including disappearing charged-track searches. However, they can be discovered by compressed electroweakino searches at a 100 TeV collider, completing the full coverage of the relic neutralino surface.
Towards the final word on neutralino dark matter
Bramante, Joseph; Desai, Nishita; Fox, Patrick; ...
2016-03-25
We present a complete phenomenological prospectus for thermal relic neutralinos. Including Sommerfeld enhancements to relic abundance and halo annihilation calculations, we obtain direct, indirect, and collider discovery prospects for all neutralinos with mass parametersmore » $$M_1,M_2,|\\mu| < 4$$ TeV, that freeze out to the observed dark matter abundance, with scalar superpartners decoupled. Much of the relic neutralino sector will be uncovered by the direct detection experiments Xenon1T and LZ, as well as indirect detection with CTA. We emphasize that thermal relic higgsinos will be found by next-generation direct detection experiments, so long as $$M_{1,2} < 4$$ TeV. Charged tracks at a 100 TeV hadron collider complement indirect searches for relic winos. Thermal relic bino-winos still evade all planned experiments, including disappearing charged-track searches. Furthermore, they can be discovered by compressed electroweakino searches at a 100 TeV collider, completing the full coverage of the relic neutralino surface.« less
Du, Hong; El-Mohri, Youcef; Zhao, Qihua; Su, Zhong; Yamamoto, Jin; Wang, Yi
2009-01-01
Active matrix, flat-panel x-ray imagers based on a-Si:H thin film transistors offer many advantages and are widely utilized in medical imaging applications. Unfortunately, the detective quantum efficiency (DQE) of conventional flat-panel imagers incorporating scintillators or a-Se photoconductors is significantly limited by their relatively modest signal to noise ratio, particularly in applications involving low x-ray exposures or high spatial resolution. For this reason, polycrystalline HgI2 is of considerable interest by virtue of its low effective work function, high atomic number, and the possibility of large-area deposition. In this study, a detailed investigation of the properties of prototype, flat-panel arrays coated with two forms of this high-gain photoconductor are reported. Encouragingly, high x-ray sensitivity, low dark current, and spatial resolution close to the theoretical limits were observed from a number of prototypes. In addition, input-quantum-limited DQE performance was measured from one of the prototypes at relatively low exposures. However, high levels of charge trapping, lag, and polarization, as well as pixel-to-pixel variations in x-ray sensitivity are of concern. While the results of the current study are promising, further development will be required to realize prototypes exhibiting the characteristics necessary to allow practical implementation of this approach. PMID:18296765
Hou, Runmin; Wang, Li; Gao, Qiang; Hou, Yuanglong; Wang, Chao
2017-09-01
This paper proposes a novel indirect adaptive fuzzy wavelet neural network (IAFWNN) to control the nonlinearity, wide variations in loads, time-variation and uncertain disturbance of the ac servo system. In the proposed approach, the self-recurrent wavelet neural network (SRWNN) is employed to construct an adaptive self-recurrent consequent part for each fuzzy rule of TSK fuzzy model. For the IAFWNN controller, the online learning algorithm is based on back propagation (BP) algorithm. Moreover, an improved particle swarm optimization (IPSO) is used to adapt the learning rate. The aid of an adaptive SRWNN identifier offers the real-time gradient information to the adaptive fuzzy wavelet neural controller to overcome the impact of parameter variations, load disturbances and other uncertainties effectively, and has a good dynamic. The asymptotical stability of the system is guaranteed by using the Lyapunov method. The result of the simulation and the prototype test prove that the proposed are effective and suitable. Copyright © 2017. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Abdulaal, R. M.; Al-Bahi, A. M.; Soliman, A. Y.; Iskanderani, F. I.
2011-08-01
A project-based active/cooperative design course is planned, implemented, assessed and evaluated to achieve several desired engineering outcomes. The course allows freshman-level students to gain professional hands-on engineering design experience through an opportunity to practise teamwork, quality principles, communication skills, life-long learning, realistic constraints and awareness of current domestic and global challenges. Throughout successive design reports and in-class assignments, the students are required by the end of the semester to communicate, clearly and concisely, the details of their design both orally and in writing through a functional artefact/prototype, a design notebook, an A0 project poster and a final oral presentation. In addition to these direct assessment tools, several indirect measures are used to ensure triangulation. Assignments are based on customer expectations using a detailed checklist. This paper shows the direct and indirect assessment tools that indicated a high level of achievement of course learning outcomes and a high level of student satisfaction.
Does the X-ray outflow quasar PDS 456 have a UV outflow at 0.3c?
NASA Astrophysics Data System (ADS)
Hamann, Fred; Chartas, George; Reeves, James; Nardini, Emanuele
2018-05-01
The quasar PDS 456 (at redshift ˜0.184) has a prototype ultra-fast outflow (UFO) measured in X-rays. This outflow is highly ionized with relativistic speeds, large total column densities log NH(cm-2) > 23, and large kinetic energies that could be important for feedback to the host galaxy. A UV spectrum of PDS 456 obtained with the Hubble Space Telescope in 2000 contains one well-measured broad absorption line (BAL) at ˜1346 Å (observed) that might be Ly α at v ≈ 0.06c or N V λ1240 at v ≈ 0.08c. However, we use photoionization models and comparisons to other outflow quasars to show that these BAL identifications are problematic because other lines that should accompany them are not detected. We argue that the UV BAL is probably C IV at v ≈ 0.30c. This would be the fastest UV outflow ever reported, but its speed is similar to the X-ray outflow and its appearance overall is similar to relativistic UV BALs observed in other quasars. The C IV BAL identification is also supported indirectly by the tentative detection of another broad C IV line at v ≈ 0.19c. The high speeds suggest that the UV outflow originates with the X-ray UFO crudely 20-30 rg from the central black hole. We speculate that the C IV BAL might form in dense clumps embedded in the X-ray UFO, requiring density enhancements of only ≳0.4 dex compared to clumpy structures already inferred for the soft X-ray absorber in PDS 456. The C IV BAL might therefore be the first detection of low-ionization clumps proposed previously to boost the opacities in UFOs for radiative driving.
Hazen, Tracy H.; Daugherty, Sean C.; Shetty, Amol; Mahurkar, Anup A.; White, Owen; Kaper, James B.; Rasko, David A.
2015-01-01
Enteropathogenic Escherichia coli (EPEC) are a leading cause of diarrheal illness among infants in developing countries. E. coli isolates classified as typical EPEC are identified by the presence of the locus of enterocyte effacement (LEE) and the bundle-forming pilus (BFP), and absence of the Shiga-toxin genes, while the atypical EPEC also encode LEE but do not encode BFP or Shiga-toxin. Comparative genomic analyses have demonstrated that EPEC isolates belong to diverse evolutionary lineages and possess lineage- and isolate-specific genomic content. To investigate whether this genomic diversity results in significant differences in global gene expression, we used an RNA sequencing (RNA-Seq) approach to characterize the global transcriptomes of the prototype typical EPEC isolates E2348/69, B171, C581-05, and the prototype atypical EPEC isolate E110019. The global transcriptomes were characterized during laboratory growth in two different media and three different growth phases, as well as during adherence of the EPEC isolates to human cells using in vitro tissue culture assays. Comparison of the global transcriptomes during these conditions was used to identify isolate- and growth phase-specific differences in EPEC gene expression. These analyses resulted in the identification of genes that encode proteins involved in survival and metabolism that were coordinately expressed with virulence factors. These findings demonstrate there are isolate- and growth phase-specific differences in the global transcriptomes of EPEC prototype isolates, and highlight the utility of comparative transcriptomics for identifying additional factors that are directly or indirectly involved in EPEC pathogenesis. PMID:26124752
Daily micro-breaks and job performance: General work engagement as a cross-level moderator.
Kim, Sooyeol; Park, YoungAh; Headrick, Lucille
2018-03-29
Despite the growing research on work recovery and its well-being outcomes, surprisingly little attention has been paid to at-work recovery and its job performance outcomes. The current study extends the work recovery literature by examining day-level relationships between prototypical microbreaks and job performance as mediated by state positive affect. Furthermore, general work engagement is tested as a cross-level moderator weakening the indirect effects of microbreaks on job performance via positive affect. Using multisource experience sampling method, the authors collected two daily surveys from 71 call center employees and obtained objective records of daily sales performance for two consecutive weeks (n = 632). Multilevel path analysis results showed that relaxation, socialization, and cognitive microbreaks were related to increased positive affect at work which, in turn, predicted greater sales performance. However, breaks for nutrition-intake (having snacks and drinks) did not show significant effects. Importantly, microbreaks had significant indirect effects on job performance via positive affect only for workers who had lower general work engagement, whereas the indirect effects did not exist for workers who had higher general work engagement. Furthermore, Bayesian multilevel analyses confirmed the results. Theoretical and practical implications, limitations, and future research directions are discussed. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Yang, Li; Liu, Xu; Zhang, Jiaxu; Xie, Jing
2017-04-12
Systematic studies of microsolvation in the gas phase have enriched our knowledge of solvent effects. Here, the dynamics of a prototype S N 2 reaction of a hydrated fluoride ion with methyl iodide is uncovered employing direct dynamics simulations that show strikingly distinct features from those determined for an unsolvated system. An indirect scattering is found to prevail, which occurs dominantly by forming hydrated F - (H 2 O)-HCH 2 I and F - (H 2 O)-CH 3 I pre-reaction complexes at low energies, but proceeds through their water-free counterparts at higher energies. This finding is in strong contrast to a general evolution from indirect to direct dynamics with enhancing energy for the unsolvated substitution reactions, and this discrepancy is understood by the substantial steric hindrance introduced by a water molecule. As established in experiments, solvation suppresses the reactivity, whereas we find that this depression is remarkably frustrated upon raising the energy given that collision-induced dehydration essentially diminishes the water block for reactive collisions. The present study sheds light on how solute-solvent interactions affect the underlying dynamics at a deeper atomic level, thereby promoting our understanding of the fundamental solvent effects on chemical reactions in solution.
Research Prototype: Automated Analysis of Scientific and Engineering Semantics
NASA Technical Reports Server (NTRS)
Stewart, Mark E. M.; Follen, Greg (Technical Monitor)
2001-01-01
Physical and mathematical formulae and concepts are fundamental elements of scientific and engineering software. These classical equations and methods are time tested, universally accepted, and relatively unambiguous. The existence of this classical ontology suggests an ideal problem for automated comprehension. This problem is further motivated by the pervasive use of scientific code and high code development costs. To investigate code comprehension in this classical knowledge domain, a research prototype has been developed. The prototype incorporates scientific domain knowledge to recognize code properties (including units, physical, and mathematical quantity). Also, the procedure implements programming language semantics to propagate these properties through the code. This prototype's ability to elucidate code and detect errors will be demonstrated with state of the art scientific codes.
Indirect detection of neutrino portal dark matter
NASA Astrophysics Data System (ADS)
Batell, Brian; Han, Tao; Shams Es Haghi, Barmak
2018-05-01
We investigate the feasibility of the indirect detection of dark matter in a simple model using the neutrino portal. The model is very economical, with right-handed neutrinos generating neutrino masses through the type-I seesaw mechanism and simultaneously mediating interactions with dark matter. Given the small neutrino Yukawa couplings expected in a type-I seesaw, direct detection and accelerator probes of dark matter in this scenario are challenging. However, dark matter can efficiently annihilate to right-handed neutrinos, which then decay via active-sterile mixing through the weak interactions, leading to a variety of indirect astronomical signatures. We derive the existing constraints on this scenario from Planck cosmic microwave background measurements, Fermi dwarf spheroidal galaxy and Galactic center gamma-ray observations, and AMS-02 antiproton observations, and we also discuss the future prospects of Fermi and the Cherenkov Telescope Array. Thermal annihilation rates are already being probed for dark matter lighter than about 50 GeV, and this can be extended to dark matter masses of 100 GeV and beyond in the future. This scenario can also provide a dark matter interpretation of the Fermi Galactic center gamma-ray excess, and we confront this interpretation with other indirect constraints. Finally we discuss some of the exciting implications of extensions of the minimal model with large neutrino Yukawa couplings and Higgs portal couplings.
van 't Veer, Anna E; Gallucci, Marcello; Stel, Mariëlle; van Beest, Ilja
2015-01-01
A pre-registered experiment was conducted to examine psychophysiological responses to being lied to. Bridging research on social cognition and deception detection, we hypothesized that observing a liar compared to a truth-teller would decrease finger skin temperature of observers. Participants first watched two targets while not forewarned that they would later be asked to judge (direct and indirect) veracity, and then watched another two targets while forewarned about this. During both these phases finger skin temperature was measured. Findings pertaining to temperature partly confirmed our main hypothesis. When participants were observing a liar, irrespective of being forewarned, on average finger skin temperature declined over time. In the forewarned phase, temperature trajectories of truth-tellers were higher than those of liars, however, in the not forewarned phase, this pattern was reversed. Results confirmed our further hypotheses that participants judge liars as less likeable and less trustworthy than truth-tellers-an indication of indirect deception detection. Our hypothesis that the effect size for trustworthiness would be bigger than that of liking was not supported by the data. Additionally, and also confirming our hypothesis, participants performed around chance level when directly judging whether the target person was lying. Exploratory analyses are reported with regard to truth bias and dependency between direct and indirect veracity judgments. Limitations and directions for future work related to the existence of psychophysiological indicators of deception detection are discussed.
Brigo, Francesco; Bragazzi, Nicola; Nardone, Raffaele; Trinka, Eugen
2016-11-01
The aim of this study was to conduct a meta-analysis of published studies to directly compare intravenous (IV) levetiracetam (LEV) with IV phenytoin (PHT) or IV valproate (VPA) as second-line treatment of status epilepticus (SE), to indirectly compare intravenous IV LEV with IV VPA using common reference-based indirect comparison meta-analysis, and to verify whether results of indirect comparisons are consistent with results of head-to-head randomized controlled trials (RCTs) directly comparing IV LEV with IV VPA. Random-effects Mantel-Haenszel meta-analyses to obtain odds ratios (ORs) for efficacy and safety of LEV versus VPA and LEV or VPA versus PHT were used. Adjusted indirect comparisons between LEV and VPA were used. Two RCTs comparing LEV with PHT (144 episodes of SE) and 3 RCTs comparing VPA with PHT (227 episodes of SE) were included. Direct comparisons showed no difference in clinical seizure cessation, neither between VPA and PHT (OR: 1.07; 95% CI: 0.57 to 2.03) nor between LEV and PHT (OR: 1.18; 95% CI: 0.50 to 2.79). Indirect comparisons showed no difference between LEV and VPA for clinical seizure cessation (OR: 1.16; 95% CI: 0.45 to 2.97). Results of indirect comparisons are consistent with results of a recent RCT directly comparing LEV with VPA. The absence of a statistically significant difference in direct and indirect comparisons is due to the lack of sufficient statistical power to detect a difference. Conducting a RCT that has not enough people to detect a clinically important difference or to estimate an effect with sufficient precision can be regarded a waste of time and resources and may raise several ethical concerns, especially in RCT on SE. Copyright © 2016 Elsevier Inc. All rights reserved.
Kascholke, Christian; Hendrikx, Stephan; Flath, Tobias; Kuzmenka, Dzmitry; Dörfler, Hans-Martin; Schumann, Dirk; Gressenbuch, Mathias; Schulze, F Peter; Schulz-Siegmund, Michaela; Hacker, Michael C
2017-11-01
Biodegradability is a crucial characteristic to improve the clinical potential of sol-gel-derived glass materials. To this end, a set of degradable organic/inorganic class II hybrids from a tetraethoxysilane(TEOS)-derived silica sol and oligovalent cross-linker oligomers containing oligo(d,l-lactide) domains was developed and characterized. A series of 18 oligomers (Mn: 1100-3200Da) with different degrees of ethoxylation and varying length of oligoester units was established and chemical composition was determined. Applicability of an established indirect rapid prototyping method enabled fabrication of a total of 85 different hybrid scaffold formulations from 3-isocyanatopropyltriethoxysilane-functionalized macromers. In vitro degradation was analyzed over 12months and a continuous linear weight loss (0.2-0.5wt%/d) combined with only moderate material swelling was detected which was controlled by oligo(lactide) content and matrix hydrophilicity. Compressive strength (2-30MPa) and compressive modulus (44-716MPa) were determined and total content, oligo(ethylene oxide) content, oligo(lactide) content and molecular weight of the oligomeric cross-linkers as well as material porosity were identified as the main factors determining hybrid mechanics. Cytocompatibility was assessed by cell culture experiments with human adipose tissue-derived stem cells (hASC). Cell migration into the entire scaffold pore network was indicated and continuous proliferation over 14days was found. ALP activity linearly increased over 2weeks indicating osteogenic differentiation. The presented glass-based hybrid concept with precisely adjustable material properties holds promise for regenerative purposes. Adaption of degradation kinetics toward physiological relevance is still an unmet challenge of (bio-)glass engineering. We therefore present a glass-derived hybrid material with adjustable degradation. A flexible design concept based on degradable multi-armed oligomers was combined with an established indirect rapid prototyping method to produce a systematic set of porous sol-gel-derived class II hybrid scaffolds. Mechanical properties in the range of cancellous bone were narrowly controlled by hybrid composition. The oligoester introduction resulted in significantly increased compressive moduli. Cytocompatible hybrids degraded in physiologically relevant time frames and a promising linear and controllable weight loss profile was found. To our knowledge, our degradation study represents the most extensive long-term investigation of sol-gel-derived class II hybrids. Due to the broad adjustability of material properties, our concept offers potential for engineering of biodegradable hybrid materials for versatile applications. Copyright © 2017. Published by Elsevier Ltd.
Sirichai, S; de Mello, A J
2001-01-01
The separation and detection of both print and film developing agents (CD-3 and CD-4) in photographic processing solutions using chip-based capillary electrophoresis is presented. For simultaneous detection of both analytes under identical experimental conditions a buffer pH of 11.9 is used to partially ionise the analytes. Detection is made possible by indirect fluorescence, where the ions of the analytes displace the anionic fluorescing buffer ion to create negative peaks. Under optimal conditions, both analytes can be analyzed within 30 s. The limits of detection for CD-3 and CD-4 are 0.17 mM and 0.39 mM, respectively. The applicability of the method for the analysis of seasoned photographic processing developer solutions is also examined.
Hart, James L; Lang, Andrew C; Leff, Asher C; Longo, Paolo; Trevor, Colin; Twesten, Ray D; Taheri, Mitra L
2017-08-15
In many cases, electron counting with direct detection sensors offers improved resolution, lower noise, and higher pixel density compared to conventional, indirect detection sensors for electron microscopy applications. Direct detection technology has previously been utilized, with great success, for imaging and diffraction, but potential advantages for spectroscopy remain unexplored. Here we compare the performance of a direct detection sensor operated in counting mode and an indirect detection sensor (scintillator/fiber-optic/CCD) for electron energy-loss spectroscopy. Clear improvements in measured detective quantum efficiency and combined energy resolution/energy field-of-view are offered by counting mode direct detection, showing promise for efficient spectrum imaging, low-dose mapping of beam-sensitive specimens, trace element analysis, and time-resolved spectroscopy. Despite the limited counting rate imposed by the readout electronics, we show that both core-loss and low-loss spectral acquisition are practical. These developments will benefit biologists, chemists, physicists, and materials scientists alike.
Sensitive detection of Escherichia coli O157:H7 based on cascade signal amplification in ELISA.
Shan, Shan; Liu, Daofeng; Guo, Qi; Wu, Songsong; Chen, Rui; Luo, Kai; Hu, Liming; Xiong, Yonghua; Lai, Weihua
2016-09-01
In this study, cascade signal amplification in ELISA involving double-antibody sandwich ELISA and indirectly competitive ELISA was established to sensitively detect Escherichia coli O157:H7. In the double-antibody sandwich ELISA, a complex was formed comprising anti-E. coli O157:H7 polyclonal antibody, E. coli O157:H7, biotinylated anti-E. coli O157:H7 monoclonal antibody, streptavidin, and biotinylated β-lactamase. Penicillin solution was then added into the ELISA well and hydrolyzed by β-lactamase. Afterward, the penicillin solution was transferred to indirectly competitive ELISA. The concentration of penicillin can be sensitively detected in indirectly competitive ELISA. In the cascade signal amplification system, increasing the amount of added E. coli O157:H7 resulted in more β-lactamase and less penicillin. The detection sensitivity of E. coli O157:H7, which was 20cfu/mL with the cascade signal amplification in ELISA, was 1,000-fold higher than that of traditional ELISA. Furthermore, the novel method can be used to detect E. coli O157:H7 in milk (2cfu/g). Therefore, this new signaling strategy will facilitate analyses of highly sensitive foodborne pathogens. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Using the Retrospective Pretest to Get Usable, Indirect Evidence of Student Learning
ERIC Educational Resources Information Center
Coulter, Shannon E.
2012-01-01
Minimal evidence exists regarding the retrospective pretest's effectiveness as a tool to obtain usable, indirect evidence of student learning in open admissions institutions. The researcher conducted this study to determine if a retrospective pretest more accurately detected a change in students' knowledge compared to a conventional…
NASA Technical Reports Server (NTRS)
Wilkins, J. R. (Inventor)
1981-01-01
The growth of microorganisms in a sample is detected and monitored by culturing microorganisms in a growth medium and detecting a change in potential between two electrodes, separated from the microbial growth by a barrier which is permeable to charged paticles but microorganism impermeable.
Boosting instance prototypes to detect local dermoscopic features.
Situ, Ning; Yuan, Xiaojing; Zouridakis, George
2010-01-01
Local dermoscopic features are useful in many dermoscopic criteria for skin cancer detection. We address the problem of detecting local dermoscopic features from epiluminescence (ELM) microscopy skin lesion images. We formulate the recognition of local dermoscopic features as a multi-instance learning (MIL) problem. We employ the method of diverse density (DD) and evidence confidence (EC) function to convert MIL to a single-instance learning (SIL) problem. We apply Adaboost to improve the classification performance with support vector machines (SVMs) as the base classifier. We also propose to boost the selection of instance prototypes through changing the data weights in the DD function. We validate the methods on detecting ten local dermoscopic features from a dataset with 360 images. We compare the performance of the MIL approach, its boosting version, and a baseline method without using MIL. Our results show that boosting can provide performance improvement compared to the other two methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Racine, E; Hautvast, G; Binnekamp, D
Purpose: To report on preliminary results validating the performance of a specially designed LDR brachytherapy needle prototype possessing both electromagnetic (EM) tracking and seed drop detection abilities. Methods: An EM hollow needle prototype has been designed and constructed in collaboration with research partner Philips Healthcare. The needle possesses conventional 3D tracking capabilities, along with a novel seed drop detection mechanism exploiting local changes of electromagnetic properties generated by the passage of seeds in the needle's embedded sensor coils. These two capabilities are exploited by proprietary engineering and signal processing techniques to generate seed drop position estimates in real-time treatment delivery.more » The electromagnetic tracking system (EMTS) used for the experiment is the NDI Aurora Planar Field Generator. The experiment consisted of dropping a total of 35 seeds in a prismatic agarose phantom, and comparing the 3D seed drop positions of the EMTS to those obtained by an image analysis of subsequent micro-CT scans. Drop position error computations and statistical analysis were performed after a 3D registration of the two seed distributions. Results: Of the 35 seeds dropped in the phantom, 32 were properly detected by the needle prototype. Absolute drop position errors among the detected seeds ranged from 0.5 to 4.8 mm with mean and standard deviation values of 1.6 and 0.9 mm, respectively. Error measurements also include undesirable and uncontrollable effects such as seed motion upon deposition. The true accuracy performance of the needle prototype is therefore underestimated. Conclusion: This preliminary study demonstrates the potential benefits of EM technologies in detecting the passage of seeds in a hollow needle as a means of generating drop position estimates in real-time treatment delivery. Such tools could therefore represent a potentially interesting addition to existing brachytherapy protocols for rapid dosimetry validation. Equipments and fundings for this project were provided by Philips Medical.« less
Van Weyenberg, Stephanie; Van Nuffel, Annelies; Lauwers, Ludwig; Vangeyte, Jürgen
2017-01-01
Simple Summary Most prototypes of systems to automatically detect lameness in dairy cattle are still not available on the market. Estimating their potential adoption rate could support developers in defining development goals towards commercially viable and well-adopted systems. We simulated the potential market shares of such prototypes to assess the effect of altering the system cost and detection performance on the potential adoption rate. We found that system cost and lameness detection performance indeed substantially influence the potential adoption rate. In order for farmers to prefer automatic detection over current visual detection, the usefulness that farmers attach to a system with specific characteristics should be higher than that of visual detection. As such, we concluded that low system costs and high detection performances are required before automatic lameness detection systems become applicable in practice. Abstract Most automatic lameness detection system prototypes have not yet been commercialized, and are hence not yet adopted in practice. Therefore, the objective of this study was to simulate the effect of detection performance (percentage missed lame cows and percentage false alarms) and system cost on the potential market share of three automatic lameness detection systems relative to visual detection: a system attached to the cow, a walkover system, and a camera system. Simulations were done using a utility model derived from survey responses obtained from dairy farmers in Flanders, Belgium. Overall, systems attached to the cow had the largest market potential, but were still not competitive with visual detection. Increasing the detection performance or lowering the system cost led to higher market shares for automatic systems at the expense of visual detection. The willingness to pay for extra performance was €2.57 per % less missed lame cows, €1.65 per % less false alerts, and €12.7 for lame leg indication, respectively. The presented results could be exploited by system designers to determine the effect of adjustments to the technology on a system’s potential adoption rate. PMID:28991188
Li, Chuanfeng; Shen, Chanjuan; Cheng, Anchun; Wang, Mingshu; Zhang, Na; Zhou, Yi; Zhu, Dekang; Jia, Renyong; Luo, Qihui; Chen, Xiaoyue
2010-01-01
An improved indirect immunoperoxidase assay (IPA) was developed to detect antigens of Duck swollen head hemorrhagic disease virus (DSHDV) in paraformaldehyde-fixed, paraffin-embedded tissues of Pekin ducks (Anas platyrhynchos). This technique used an indirect streptavidin-alkaline phosphatase labeling system with polyclonal antiserum developed against purified DSHDV antigens. Specimens from the experimentally inoculated Pekin ducks with DSHDV and archived paraffin-embedded tissues from natural cases of Duck viral swollen head hemorrhagic disease (DVSHD) were examined by clinical and histological criteria. Positive staining was most widely observed in the cytoplasm of the following organs: immune, digestive, and urinary organs, heart, lung, and trachea, which corresponded to the intracellular distribution of reovirus. The DSHDV antigens were first detected at 4 hr postinoculation in the bursa of Fabricius of infected ducks. Therefore, this method was suitable for the early diagnosis of DVSHD. Immunoperoxidase staining was not present in tissues and organs of sham-inoculated ducks (negative control). The IPA developed in the current study is a convenient, sensitive, and specific means of detecting DSHDV and is applicable to routine diagnosis, retrospective studies, and prospective studies of DSHDV infection in ducks.
Varden, Lara; Bou-Abdallah, Fadi
2017-01-01
Capillary zone electrophoresis (CZE) is a sensitive and rapid technique for determining traces of inorganic cations in water samples. CZE with indirect UV-diode array detection (CZE-DAD) was utilized to identify several inorganic cations in natural, potable, and wastewater samples. A pH 4.35 background electrolyte system was employed and consisted of 15 mM imidazole, 8 mM malonic acid, 2 mM 18-crown-6 ether as complexing agents, 10% v/v methanol as an organic modifier with indirect absorbance reference at 214 nm. The CZE method involved electromigration injection at 5 kV for 5 s, a separation voltage of 20 kV at 25°C, and a detection wavelength of 280 nm. Six main cations (ammonium NH4+, potassium K+, calcium Ca2+, sodium Na+, magnesium Mg2+, and lead Pb2+) were tested, and all but lead, were detected in the water samples at concentrations between 0.03 and 755 ppm with a detection limit ranging between 0.023 and 0.084 ppm. The successful evaluation of the proposed methodology allowed us to reliably detect and separate six metal ions in different water samples without any pretreatment. All water samples were collected from Northern New York towns and the Raquette River water system, the third longest river in New York State and the largest watershed of the central and western Adirondacks. PMID:29057144
NASA Astrophysics Data System (ADS)
Chen, Hao; De Feyter, Henk M.; Brown, Peter B.; Rothman, Douglas L.; Cai, Shuhui; de Graaf, Robin A.
2017-10-01
A wide range of direct 13C and indirect 1H-[13C] MR detection methods exist to probe dynamic metabolic pathways in the human brain. Choosing an optimal detection method is difficult as sequence-specific features regarding spatial localization, broadband decoupling, spectral resolution, power requirements and sensitivity complicate a straightforward comparison. Here we combine density matrix simulations with experimentally determined values for intrinsic 1H and 13C sensitivity, T1 and T2 relaxation and transmit efficiency to allow selection of an optimal 13C MR detection method for a given application and magnetic field. The indirect proton-observed, carbon-edited (POCE) detection method provides the highest accuracy at reasonable RF power deposition both at 4 T and 7 T. The various polarization transfer methods all have comparable performances, but may become infeasible at 7 T due to the high RF power deposition. 2D MR methods have limited value for the metabolites considered (primarily glutamate, glutamine and γ-amino butyric acid (GABA)), but may prove valuable when additional information can be extracted, such as isotopomers or lipid composition. While providing the lowest accuracy, the detection of non-protonated carbons is the simplest to implement with the lowest RF power deposition. The magnetic field homogeneity is one of the most important parameters affecting the detection accuracy for all metabolites and all acquisition methods.
Image Analysis Based on Soft Computing and Applied on Space Shuttle During the Liftoff Process
NASA Technical Reports Server (NTRS)
Dominquez, Jesus A.; Klinko, Steve J.
2007-01-01
Imaging techniques based on Soft Computing (SC) and developed at Kennedy Space Center (KSC) have been implemented on a variety of prototype applications related to the safety operation of the Space Shuttle during the liftoff process. These SC-based prototype applications include detection and tracking of moving Foreign Objects Debris (FOD) during the Space Shuttle liftoff, visual anomaly detection on slidewires used in the emergency egress system for the Space Shuttle at the laJlIlch pad, and visual detection of distant birds approaching the Space Shuttle launch pad. This SC-based image analysis capability developed at KSC was also used to analyze images acquired during the accident of the Space Shuttle Columbia and estimate the trajectory and velocity of the foam that caused the accident.
Yan, Sheng; Zhu, Yuanqing; Tang, Shi-Yang; Li, Yuxing; Zhao, Qianbin; Yuan, Dan; Yun, Guolin; Zhang, Jun; Zhang, Shiwu; Li, Weihua
2018-04-01
Proteinuria is an established risk marker for progressive renal function loss and patients would significantly benefit from a point-of-care testing. Although extensive work has been done to develop the microfluidic devices for the detection of urinary protein, they need the complicated operation and bulky peripherals. Here, we present a rapid, maskless 3D prototyping for fabrication of capillary fluidic circuits using laser engraving. The capillary circuits can be fabricated in a short amount of time (<10 min) without the requirements of clean-room facilities and photomasks. The advanced capillary components (e.g., trigger valves, retention valves and retention bursting valves) were fabricated, enabling the sequential liquid delivery and sample-reagent mixing. With the integration of smartphone-based detection platform, the microfluidic device can quantify the urinary protein via a colorimetric analysis. By eliminating the bulky and expensive equipment, this smartphone-based detection platform is portable for on-site quantitative detection. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Li, Zedong; Li, Fei; Xing, Yue; Liu, Zhi; You, Minli; Li, Yingchun; Wen, Ting; Qu, Zhiguo; Ling Li, Xiao; Xu, Feng
2017-12-15
Paper-based microfluidic biosensors have recently attracted increasing attentions in point-of-care testing (POCT) territories benefiting from their affordable, accessible and eco-friendly features, where technologies for fabricating such biosensors are preferred to be equipment free, easy-to-operate and capable of rapid prototyping. In this work, we developed a pen-on-paper (PoP) strategy based on two custom-made pens, i.e., a wax pen and a conductive-ink pen, to fully write paper-based microfluidic biosensors through directly writing both microfluidic channels and electrodes. Particularly, the proposed wax pen is competent to realize one-step fabrication of wax channels on paper, as the melted wax penetrates into paper during writing process without any post-treatments. The practical applications of the fabricated paper-based microfluidic biosensors are demonstrated by both colorimetric detection of Salmonella typhimurium DNA with detection limit of 1nM and electrochemical measurement of glucose with detection limit of 1mM. The developed PoP strategy for making microfluidic biosensors on paper characterized by true simplicity, prominent portability and excellent capability for rapid prototyping shows promising prospect in POCT applications. Copyright © 2017 Elsevier B.V. All rights reserved.
Neutron multiplicity ,easurements With 3He alternative: Straw neutron detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukhopadhyay, Sanjoy; Wolff, Ronald S.; Meade, John A.
Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. In this study, a prototype neutron detector was built using 10B as the converter in a special form factor called “straws” that would address the above problems by looking into the details of multiplicity distributions ofmore » neutrons originating from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10B (in the form of enriched boron carbide: 10B 4C) for neutron detection instead of 3He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect neutron multiplicity information from spontaneous fission sources using a single panel consisting of 60 straws equally distributed over three rows in high-density polyethylene moderator. In the following year, we developed the field-programmable gate array and associated DAQ software. Finally, this SDRD effort successfully produced a prototype NMC with ~33% detection efficiency compared to a commercial fission meter.« less
Neutron multiplicity measurements with 3He alternative: Straw neutron detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukhopadhyay, Sanjoy; Wolff, Ronald; Detwiler, Ryan
Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as ‘‘ship effect ’’) and to the complicated nature of the neutron scattering in that environment. A prototype neutron detector was built using 10B as the converter in a special form factor called ‘‘straws’’ that would address the above problems by looking into the details of multiplicity distributions of neutrons originatingmore » from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10B (in the form of enriched boron carbide: 10B 4C) for neutron detection instead of 3He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect neutron multiplicity information from spontaneous fission sources using a single panel consisting of 60 straws equally distributed over three rows in high-density polyethylenemoderator. In the following year, we developed the field-programmable gate array and associated DAQ software. This SDRD effort successfully produced a prototype NMC with*33% detection efficiency compared to a commercial fission meter.« less
Neutron multiplicity ,easurements With 3He alternative: Straw neutron detectors
Mukhopadhyay, Sanjoy; Wolff, Ronald S.; Meade, John A.; ...
2015-01-27
Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. In this study, a prototype neutron detector was built using 10B as the converter in a special form factor called “straws” that would address the above problems by looking into the details of multiplicity distributions ofmore » neutrons originating from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10B (in the form of enriched boron carbide: 10B 4C) for neutron detection instead of 3He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect neutron multiplicity information from spontaneous fission sources using a single panel consisting of 60 straws equally distributed over three rows in high-density polyethylene moderator. In the following year, we developed the field-programmable gate array and associated DAQ software. Finally, this SDRD effort successfully produced a prototype NMC with ~33% detection efficiency compared to a commercial fission meter.« less
Improvement of immunoassay detection system by using alternating current magnetic susceptibility
NASA Astrophysics Data System (ADS)
Kawabata, R.; Mizoguchi, T.; Kandori, A.
2016-03-01
A major goal with this research was to develop a low-cost and highly sensitive immunoassay detection system by using alternating current (AC) magnetic susceptibility. We fabricated an improved prototype of our previously developed immunoassay detection system and evaluated its performance. The prototype continuously moved sample containers by using a magnetically shielded brushless motor, which passes between two anisotropic magneto resistance (AMR) sensors. These sensors detected the magnetic signal in the direction where each sample container passed them. We used the differential signal obtained from each AMR sensor's output to improve the signal-to-noise ratio (SNR) of the magnetic signal measurement. Biotin-conjugated polymer beads with avidin-coated magnetic particles were prepared to examine the calibration curve, which represents the relation between AC magnetic susceptibility change and polymer-bead concentration. For the calibration curve measurement, we, respectively, measured the magnetic signal caused by the magnetic particles by using each AMR sensor installed near the upper or lower part in the lateral position of the passing sample containers. As a result, the SNR of the prototype was 4.5 times better than that of our previous system. Moreover, the data obtained from each AMR sensor installed near the upper part in the lateral position of the passing sample containers exhibited an accurate calibration curve that represented good correlation between AC magnetic susceptibility change and polymer-bead concentration. The conclusion drawn from these findings is that our improved immunoassay detection system will enable a low-cost and highly sensitive immunoassay.
Improvement of immunoassay detection system by using alternating current magnetic susceptibility.
Kawabata, R; Mizoguchi, T; Kandori, A
2016-03-01
A major goal with this research was to develop a low-cost and highly sensitive immunoassay detection system by using alternating current (AC) magnetic susceptibility. We fabricated an improved prototype of our previously developed immunoassay detection system and evaluated its performance. The prototype continuously moved sample containers by using a magnetically shielded brushless motor, which passes between two anisotropic magneto resistance (AMR) sensors. These sensors detected the magnetic signal in the direction where each sample container passed them. We used the differential signal obtained from each AMR sensor's output to improve the signal-to-noise ratio (SNR) of the magnetic signal measurement. Biotin-conjugated polymer beads with avidin-coated magnetic particles were prepared to examine the calibration curve, which represents the relation between AC magnetic susceptibility change and polymer-bead concentration. For the calibration curve measurement, we, respectively, measured the magnetic signal caused by the magnetic particles by using each AMR sensor installed near the upper or lower part in the lateral position of the passing sample containers. As a result, the SNR of the prototype was 4.5 times better than that of our previous system. Moreover, the data obtained from each AMR sensor installed near the upper part in the lateral position of the passing sample containers exhibited an accurate calibration curve that represented good correlation between AC magnetic susceptibility change and polymer-bead concentration. The conclusion drawn from these findings is that our improved immunoassay detection system will enable a low-cost and highly sensitive immunoassay.
NASA Astrophysics Data System (ADS)
Ohgaki, H.; Daito, I.; Zen, H.; Kii, T.; Masuda, K.; Misawa, T.; Hajima, R.; Hayakawa, T.; Shizuma, T.; Kando, M.; Fujimoto, S.
2017-07-01
A Neutron/Gamma-ray combined inspection system for hidden special nuclear materials (SNMs) in cargo containers has been developed under a program of Japan Science and Technology Agency in Japan. This inspection system consists of an active neutron-detection system for fast screening and a laser Compton backscattering gamma-ray source in coupling with nuclear resonance fluorescence (NRF) method for precise inspection. The inertial electrostatic confinement fusion device has been adopted as a neutron source and two neutron-detection methods, delayed neutron noise analysis method and high-energy neutron-detection method, have been developed to realize the fast screening system. The prototype system has been constructed and tested in the Reactor Research Institute, Kyoto University. For the generation of the laser Compton backscattering gamma-ray beam, a race track microtron accelerator has been used to reduce the size of the system. For the NRF measurement, an array of LaBr3(Ce) scintillation detectors has been adopted to realize a low-cost detection system. The prototype of the gamma-ray system has been demonstrated in the Kansai Photon Science Institute, National Institutes for Quantum and Radiological Science and Technology. By using numerical simulations based on the data taken from these prototype systems and the inspection-flow, the system designed by this program can detect 1 kg of highly enriched 235U (HEU) hidden in an empty 20-ft container within several minutes.
Heavy Oil Detection (Prototypes)
2009-06-01
accomplish a variety of tasks to be successful. These include detecting the oil, possibly concentrating/ corralling the oil for collection, and...structures (e.g., reefs , cables, and pipelines). Other non-contact seafloor survey techniques such as ROV video surveys pose the additional
On-line high-speed rail defect detection : research results.
DOT National Transportation Integrated Search
2008-08-01
The rail defect detection prototype, which is being developed by the University of California-San Diego (UCSD) under a Federal Railroad Administration (FRA) Office of Research and Development (R&D) grant, has produced encouraging results in recent fi...
Wet chemistry instrument prototype
NASA Technical Reports Server (NTRS)
1974-01-01
A wet chemistry instrument prototype for detecting amino acids in planetary soil samples was developed. The importance of amino acids and their condensation products to the development of life forms is explained. The characteristics of the instrument and the tests which were conducted to determine the materials compatibility are described. Diagrams are provided to show the construction of the instrument. Data obtained from the performance tests are reported.
DOE`s annealing prototype demonstration projects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warren, J.; Nakos, J.; Rochau, G.
1997-02-01
One of the challenges U.S. utilities face in addressing technical issues associated with the aging of nuclear power plants is the long-term effect of plant operation on reactor pressure vessels (RPVs). As a nuclear plant operates, its RPV is exposed to neutrons. For certain plants, this neutron exposure can cause embrittlement of some of the RPV welds which can shorten the useful life of the RPV. This RPV embrittlement issue has the potential to affect the continued operation of a number of operating U.S. pressurized water reactor (PWR) plants. However, RPV material properties affected by long-term irradiation are recoverable throughmore » a thermal annealing treatment of the RPV. Although a dozen Russian-designed RPVs and several U.S. military vessels have been successfully annealed, U.S. utilities have stated that a successful annealing demonstration of a U.S. RPV is a prerequisite for annealing a licensed U.S. nuclear power plant. In May 1995, the Department of Energy`s Sandia National Laboratories awarded two cost-shared contracts to evaluate the feasibility of annealing U.S. licensed plants by conducting an anneal of an installed RPV using two different heating technologies. The contracts were awarded to the American Society of Mechanical Engineers (ASME) Center for Research and Technology Development (CRTD) and MPR Associates (MPR). The ASME team completed its annealing prototype demonstration in July 1996, using an indirect gas furnace at the uncompleted Public Service of Indiana`s Marble Hill nuclear power plant. The MPR team`s annealing prototype demonstration was scheduled to be completed in early 1997, using a direct heat electrical furnace at the uncompleted Consumers Power Company`s nuclear power plant at Midland, Michigan. This paper describes the Department`s annealing prototype demonstration goals and objectives; the tasks, deliverables, and results to date for each annealing prototype demonstration; and the remaining annealing technology challenges.« less
Array microscopy technology and its application to digital detection of Mycobacterium tuberculosis
NASA Astrophysics Data System (ADS)
McCall, Brian P.
Tuberculosis causes more deaths worldwide than any other curable infectious disease. This is the case despite tuberculosis appearing to be on the verge of eradication midway through the last century. Efforts at reversing the spread of tuberculosis have intensified since the early 1990s. Since then, microscopy has been the primary frontline diagnostic. In this dissertation, advances in clinical microscopy towards array microscopy for digital detection of Mycobacterium tuberculosis are presented. Digital array microscopy separates the tasks of microscope operation and pathogen detection and will reduce the specialization needed in order to operate the microscope. Distributing the work and reducing specialization will allow this technology to be deployed at the point of care, taking the front-line diagnostic for tuberculosis from the microscopy center to the community health center. By improving access to microscopy centers, hundreds of thousands of lives can be saved. For this dissertation, a lens was designed that can be manufactured as 4x6 array of microscopes. This lens design is diffraction limited, having less than 0.071 waves of aberration (root mean square) over the entire field of view. A total area imaged onto a full-frame digital image sensor is expected to be 3.94 mm2, which according to tuberculosis microscopy guidelines is more than sufficient for a sensitive diagnosis. The design is tolerant to single point diamond turning manufacturing errors, as found by tolerance analysis and by fabricating a prototype. Diamond micro-milling, a fabrication technique for lens array molds, was applied to plastic plano-concave and plano-convex lens arrays, and found to produce high quality optical surfaces. The micro-milling technique did not prove robust enough to produce bi-convex and meniscus lens arrays in a variety of lens shapes, however, and it required lengthy fabrication times. In order to rapidly prototype new lenses, a new diamond machining technique was developed called 4-axis single point diamond machining. This technique is 2-10x faster than micro-milling, depending on how advanced the micro-milling equipment is. With array microscope fabrication still in development, a single prototype of the lens designed for an array microscope was fabricated using single point diamond turning. The prototype microscope objective was validated in a pre-clinical trial. The prototype was compared with a standard clinical microscope objective in diagnostic tests. High concordance, a Fleiss's kappa of 0.88, was found between diagnoses made using the prototype and standard microscope objectives and a reference test. With the lens designed and validated and an advanced fabrication process developed, array microscopy technology is advanced to the point where it is feasible to rapidly prototype an array microscope for detection of tuberculosis and translate array microscope from an innovative concept to a device that can save lives.
Yamamoto, S; Han, L; Noiri, Y; Okiji, T
2017-12-01
To evaluate the Ca 2+ -releasing, alkalizing and apatite-like surface precipitate-forming abilities of a prototype tricalcium silicate cement, which was mainly composed of synthetically prepared tricalcium silicate and zirconium oxide radiopacifier. The prototype tricalcium silicate cement, white ProRoot MTA (WMTA) and TheraCal LC (a light-cured resin-modified calcium silicate-filled material) were examined. The chemical compositions were analysed with a wavelength-dispersive X-ray spectroscopy electron probe microanalyser with an image observation function (SEM-EPMA). The pH and Ca 2+ concentrations of water in which the set materials had been immersed were measured, and the latter was assessed with the EDTA titration method. The surface precipitates formed on the materials immersed in phosphate-buffered saline (PBS) were analysed with SEM-EPMA and X-ray diffraction (XRD). Kruskal-Wallis tests followed by Mann-Whitney U-test with Bonferroni correction were used for statistical analysis (α = 0.05). The prototype cement contained Ca, Si and Zr as major elemental constituents, whereas it did not contain some metal elements that were detected in the other materials. The Ca 2+ concentrations and pH of the immersion water samples exhibited the following order: WMTA = prototype cement > TheraCal LC (P < 0.05). All three materials produced Ca- and P-containing surface precipitates after PBS immersion, and the precipitates produced by TheraCal LC displayed lower Ca/P ratios than those formed by the other materials. XRD peaks corresponding to hydroxyapatite were detected in the precipitates produced by the prototype cement and WMTA. The prototype tricalcium silicate cement exhibited similar Ca 2+ -releasing, alkalizing and apatite-like precipitate-forming abilities to WMTA. The Ca 2+ -releasing, alkalizing and apatite-like precipitate-forming abilities of TheraCal LC were lower than those of the other materials. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Sabol, John M.; Avinash, Gopal B.; Nicolas, Francois; Claus, Bernhard E. H.; Zhao, Jianguo; Dobbins, James T., III
2001-06-01
Dual-energy subtraction imaging increases the sensitivity and specificity of pulmonary nodule detection in chest radiography by reducing the contrast of overlying bone structures. Recent development of a fast, high-efficiency detector enables dual-energy imaging to be integrated into the traditional workflow. We have modified a GE RevolutionTM XQ/i chest imaging system to construct a dual-energy imaging prototype system. Here we describe the operating characteristics of this prototype and evaluate image quality. Empirical results show that the dual-energy CNR is maximized if the dose is approximately equal for both high and low energy exposures. Given the high detector DQE, and allocation of dose between the two views, we can acquire dual-energy PA and conventional lateral images with total dose equivalent to a conventional two-view film chest exam. Calculations have shown that the dual-exposure technique has superior CNR and tissue cancellation than single-exposure CR systems. Clinical images obtained on a prototype dual-energy imaging system show excellent tissue contrast cancellation, low noise, and modest motion artefacts. In summary, a prototype dual-energy system has been constructed which enables rapid, dual-exposure imaging of the chest using a commercially available high-efficiency, flat-panel x-ray detector. The quality of the clinical images generated with this prototype exceeds that of CR techniques and demonstrates the potential for improved detection and characterization of lung disease through dual-energy imaging.
Shen, Ming; Trébosc, J; Lafon, O; Pourpoint, F; Hu, Bingwen; Chen, Qun; Amoureux, J-P
2014-08-01
Connectivities and proximities between protons and low-gamma nuclei can be probed in solid-state NMR spectroscopy using two-dimensional (2D) proton-detected heteronuclear correlation, through Heteronuclear Multiple Quantum Correlation (HMQC) pulse sequence. The indirect detection via protons dramatically enhances the sensitivity. However, the spectra are often broadened along the indirect F1 dimension by the decay of heteronuclear multiple-quantum coherences under the strong (1)H-(1)H dipolar couplings. This work presents a systematic comparison of the performances of various decoupling schemes during the indirect t1 evolution period of dipolar-mediated HMQC (D-HMQC) experiment. We demonstrate that (1)H-(1)H dipolar decoupling sequences during t1, such as symmetry-based schemes, phase-modulated Lee-Goldburg (PMLG) and Decoupling Using Mind-Boggling Optimization (DUMBO), provide better resolution than continuous wave (1)H irradiation. We also report that high resolution requires the preservation of (1)H isotropic chemical shifts during the decoupling sequences. When observing indirectly broad spectra presenting numerous spinning sidebands, the D-HMQC sequence must be fully rotor-synchronized owing to the rotor-synchronized indirect sampling and dipolar recoupling sequence employed. In this case, we propose a solution to reduce artefact sidebands caused by the modulation of window delays before and after the decoupling application during the t1 period. Moreover, we show that (1)H-(1)H dipolar decoupling sequence using Smooth Amplitude Modulation (SAM) minimizes the t1-noise. The performances of the various decoupling schemes are assessed via numerical simulations and compared to 2D (1)H-{(13)C} D-HMQC experiments on [U-(13)C]-L-histidine⋅HCl⋅H2O at various magnetic fields and Magic Angle spinning (MAS) frequencies. Great resolution and sensitivity enhancements resulting from decoupling during t1 period enable the detection of heteronuclear correlation between aliphatic protons and ammonium (14)N sites in L-histidine⋅HCl⋅H2O. Copyright © 2014 Elsevier Inc. All rights reserved.
A prototype of mammography CADx scheme integrated to imaging quality evaluation techniques
NASA Astrophysics Data System (ADS)
Schiabel, Homero; Matheus, Bruno R. N.; Angelo, Michele F.; Patrocínio, Ana Claudia; Ventura, Liliane
2011-03-01
As all women over the age of 40 are recommended to perform mammographic exams every two years, the demands on radiologists to evaluate mammographic images in short periods of time has increased considerably. As a tool to improve quality and accelerate analysis CADe/Dx (computer-aided detection/diagnosis) schemes have been investigated, but very few complete CADe/Dx schemes have been developed and most are restricted to detection and not diagnosis. The existent ones usually are associated to specific mammographic equipment (usually DR), which makes them very expensive. So this paper describes a prototype of a complete mammography CADx scheme developed by our research group integrated to an imaging quality evaluation process. The basic structure consists of pre-processing modules based on image acquisition and digitization procedures (FFDM, CR or film + scanner), a segmentation tool to detect clustered microcalcifications and suspect masses and a classification scheme, which evaluates as the presence of microcalcifications clusters as well as possible malignant masses based on their contour. The aim is to provide enough information not only on the detected structures but also a pre-report with a BI-RADS classification. At this time the system is still lacking an interface integrating all the modules. Despite this, it is functional as a prototype for clinical practice testing, with results comparable to others reported in literature.
Myers, T J; Schat, K A; Mockett, A P
1989-01-01
Immunoglobulin class-specific enzyme-linked immunosorbent assays were developed for detecting antibodies against avian rotavirus in serum, intestinal contents, and bile from experimentally infected specific-pathogen-free (SPF) chickens. Both indirect and antibody-capture (AbC) assays were developed based on monoclonal antibodies specific for chicken IgG, IgM, and IgA. Treatment of purified rotavirus with sodium thiocyanate before coating the plate improved the rotavirus-specific reading in the indirect assay. Use of Immunolon 2 plates facilitated attachment of monoclonal antibodies to the plate in the AbC assay. Addition of 5% powdered skim milk to the diluent buffer reduced nonspecific background readings. The indirect assay was superior for detecting rotavirus-specific IgG, whereas the AbC assay was better for detecting rotavirus-specific IgM and IgA. The presence of intestinal contents in the assay wells did not reduce the measurable titers of IgG, IgM, or IgA. These assays showed that SPF chickens produced systemic and mucosal antibodies against avian rotavirus.
Sakamoto, Seiichi; Kohno, Toshitaka; Shimizu, Kuniyoshi; Tanaka, Hiroyuki; Morimoto, Satoshi
2016-05-01
Ganoderma is a genus of medicinal mushroom traditionally used for treating various diseases. Ganoderic acid A is one of the major bioactive Ganoderma triterpenoids isolated from Ganoderma species. Herein, we produced a highly specific monoclonal antibody against ganoderic acid A (MAb 12 A) and developed an indirect competitive ELISA for the highly sensitive detection of ganoderic acid A in Ganoderma lingzhi, with a limit of detection of 6.10 ng/mL. Several validation analyses support the accuracy and reliability of the developed indirect competitive ELISA for use in the quality control of Ganoderma based on ganoderic acid A content. Furthermore, quantitative analysis of ganoderic acid A in G. lingzhi revealed that the pileus exhibits the highest ganoderic acid A content compared with the stipe and spore of the fruiting body; the best extraction efficiency was found when 50 % ethanol was used, which suggests the use of a strong liquor to completely harness the potential of Ganoderma triterpenoids in daily life. Georg Thieme Verlag KG Stuttgart · New York.
Progress In The Development Of A Tomographic SPECT System For Online Dosimetry In BNCT
NASA Astrophysics Data System (ADS)
Minsky, D. M.; Valda, A.; Kreiner, A. J.; Burlon, A. A.; Green, S.; Wojnecki, C.; Ghani, Z.
2010-08-01
In boron neutron capture therapy (BNCT) the delivered dose to the patient depends both on the neutron beam characteristics and on the 10B body distribution which, in turn, is governed by the tumor specificity of the 10B drug-carrier. BNCT dosimetry is a complex matter due to the several interactions that neutrons can undergo with the different nuclei present in tissue. However the boron capture reaction 10B(n,α)7Li accounts for about 80 % of the total dose in a tumor with 40 ppm in 10B concentration. Present dosimetric methods are indirect, based on drug biodistribution statistical data and subjected to inter and intra-patient variability. In order to overcome the consequences of the concomitant high dosimetric uncertainties, we propose a SPECT (Single Photon Emission Tomography) approach based on the detection of the prompt gamma-ray (478 keV) emitted in 94 % of the cases from 7Li. For this purpose we designed, built and tested a prototype based on LaBr3(Ce) scintillators. Measurements on a head and tumor phantom were performed in the accelerator-based BNCT facility of the University of Birmingham (UK). They result in the first tomographic image of the 10B capture distribution obtained in a BNCT facility.
Simulation Test System of Non-Contact D-dot Voltage Transformer
NASA Astrophysics Data System (ADS)
Yang, Jie; Wang, Jingang; Luo, Ruixi; Gao, Can; Songnong, Li; Kongjun, Zhou
2016-04-01
The development trend of future voltage transformer in smart grid is non-contact measurement, miniaturization and intellectualization. This paper proposes one simulation test system of non-contact D-dot transformer for voltage measurement. This simulation test system consists of D-dot transformer, signal processing circuit and ground PC port. D-dot transformer realizes the indirect voltage measurement by measuring the change rate of electric displacement vector, a non-contact means (He et al. 2004, Principles and experiments of voltage transformer based on self-integrating D-dot probe. Proc CSEE 2014;15:2445-51). Specific to the characteristics of D-dot transformer signals, signal processing circuits with strong resistance to interference and distortion-free amplified sensor output signal are designed. WIFI wireless network is used to transmit the voltage detection to LabVIEW-based ground collection port and LabVIEW technology is adopted for signal reception, data processing and analysis and other functions. Finally, a test platform is established to simulate the performance of the whole test system of single-phase voltage transformer. Test results indicate that this voltage transformer has sound real-time performance, high accuracy and fast response speed and the simulation test system is stable and reliable and can be a new prototype of voltage transformers.
Indirect competitive assays on DVD for direct multiplex detection of drugs of abuse in oral fluids.
Zhang, Lingling; Li, Xiaochun; Li, Yunchao; Shi, Xiaoli; Yu, Hua-Zhong
2015-02-03
On-site oral fluid testing for drugs of abuse has become prominent in order to take immediate administrative action in an enforcement process. Herein, we report a DVD technology-based indirect competitive immunoassay platform for the quantitative detection of drugs of abuse. A microfluidic approach was adapted to prepare multiplex immunoassays on a standard DVD-R, an unmodified multimode DVD/Blu-Ray drive to read signal, and a free disc-quality analysis software program to process the data. The DVD assay platform was successfully demonstrated for the simultaneous, quantitative detection of drug candidates (morphine and cocaine) in oral fluids with high selectivity. The detection limit achieved was as low as 1.0 ppb for morphine and 5.0 ppb for cocaine, comparable with that of standard mass spectrometry and ELISA methods.
Random phase detection in multidimensional NMR.
Maciejewski, Mark W; Fenwick, Matthew; Schuyler, Adam D; Stern, Alan S; Gorbatyuk, Vitaliy; Hoch, Jeffrey C
2011-10-04
Despite advances in resolution accompanying the development of high-field superconducting magnets, biomolecular applications of NMR require multiple dimensions in order to resolve individual resonances, and the achievable resolution is typically limited by practical constraints on measuring time. In addition to the need for measuring long evolution times to obtain high resolution, the need to distinguish the sign of the frequency constrains the ability to shorten measuring times. Sign discrimination is typically accomplished by sampling the signal with two different receiver phases or by selecting a reference frequency outside the range of frequencies spanned by the signal and then sampling at a higher rate. In the parametrically sampled (indirect) time dimensions of multidimensional NMR experiments, either method imposes an additional factor of 2 sampling burden for each dimension. We demonstrate that by using a single detector phase at each time sample point, but randomly altering the phase for different points, the sign ambiguity that attends fixed single-phase detection is resolved. Random phase detection enables a reduction in experiment time by a factor of 2 for each indirect dimension, amounting to a factor of 8 for a four-dimensional experiment, albeit at the cost of introducing sampling artifacts. Alternatively, for fixed measuring time, random phase detection can be used to double resolution in each indirect dimension. Random phase detection is complementary to nonuniform sampling methods, and their combination offers the potential for additional benefits. In addition to applications in biomolecular NMR, random phase detection could be useful in magnetic resonance imaging and other signal processing contexts.
The load shedding advisor: An example of a crisis-response expert system
NASA Technical Reports Server (NTRS)
Bollinger, Terry B.; Lightner, Eric; Laverty, John; Ambrose, Edward
1987-01-01
A Prolog-based prototype expert system is described that was implemented by the Network Operations Branch of the NASA Goddard Space Flight Center. The purpose of the prototype was to test whether a small, inexpensive computer system could be used to host a load shedding advisor, a system which would monitor major physical environment parameters in a computer facility, then recommend appropriate operator reponses whenever a serious condition was detected. The resulting prototype performed significantly to efficiency gains achieved by replacing a purely rule-based design methodology with a hybrid approach that combined procedural, entity-relationship, and rule-based methods.
NASA Astrophysics Data System (ADS)
Ageron, M.; Aguilar, J. A.; Albert, A.; Ameli, F.; Anghinolfi, M.; Anton, G.; Anvar, S.; Ardellier-Desages, F.; Aslanides, E.; Aubert, J.-J.; Auer, R.; Barbarito, E.; Basa, S.; Battaglieri, M.; Bazzotti, M.; Becherini, Y.; Béthoux, N.; Beltramelli, J.; Bertin, V.; Bigi, A.; Billault, M.; Blaes, R.; de Botton, N.; Bouwhuis, M. C.; Bruijn, R.; Brunner, J.; Burgio, G. F.; Busto, J.; Cafagna, F.; Caillat, L.; Calzas, A.; Capone, A.; Caponetto, L.; Carmona, E.; Carr, J.; Castel, D.; Castorina, E.; Cavasinni, V.; Cecchini, S.; Ceres, A.; Charvis, P.; Chauchot, P.; Chiarusi, T.; Circella, M.; Coail, J.-Y.; Colnard, C.; Compére, C.; Coniglione, R.; Cottini, N.; Coyle, P.; Cuneo, S.; Cussatlegras, A.-S.; Damy, G.; van Dantzig, R.; Debonis, G.; de Marzo, C.; de Vita, R.; Dekeyser, I.; Delagnes, E.; Denans, D.; Deschamps, A.; Dessa, J.-X.; Destelle, J.-J.; Dinkespieler, B.; Distefano, C.; Donzaud, C.; Drogou, J.-F.; Druillole, F.; Durand, D.; Ernenwein, J.-P.; Escoffier, S.; Falchini, E.; Favard, S.; Fehr, F.; Feinstein, F.; Fiorello, C.; Flaminio, V.; Fratini, K.; Fuda, J.-L.; Galeotti, S.; Gallone, J.-M.; Giacomelli, G.; Girard, N.; Gojak, C.; Goret, Ph.; Graf, K.; Guilloux, F.; Hallewell, G.; Harakeh, M. N.; Hartmann, B.; Heijboer, A.; Heine, E.; Hello, Y.; Hernández-Rey, J. J.; Hößl, J.; Hoffman, C.; Hogenbirk, J.; Hubbard, J. R.; Jaquet, M.; Jaspers, M.; de Jong, M.; Jouvenot, F.; Kalantar-Nayestanaki, N.; Kappes, A.; Karg, T.; Katz, U.; Keller, P.; Kneib, J. P.; Kok, E.; Kok, H.; Kooijman, P.; Kopper, C.; Kouchner, A.; Kretschmer, W.; Kruijer, A.; Kuch, S.; Lagier, P.; Lahmann, R.; Lamanna, G.; Lamare, P.; Lambard, G.; Languillat, J. C.; Laschinsky, H.; Lavalle, J.; Le Guen, Y.; Le Provost, H.; Le van Suu, A.; Lefévre, D.; Legou, T.; Lelaizant, G.; Lim, G.; Lo Presti, D.; Loaec, G.; Loehner, H.; Loucatos, S.; Louis, F.; Lucarelli, F.; Lyashuk, V.; Mangano, S.; Marcelin, M.; Margiotta, A.; Masullo, R.; Mazéas, F.; Mazure, A.; Megna, R.; Melissas, M.; Migneco, E.; Mongelli, M.; Montaruli, T.; Morganti, M.; Moscoso, L.; Motz, H.; Musumeci, M.; Naumann, C.; Naumann-Godo, M.; Niess, V.; Noble, A.; Olivetto, C.; Ostasch, R.; Palanque-Delabrouille, N.; Payre, P.; Peek, H. Z.; Perez, A.; Petta, C.; Piattelli, P.; Pillet, R.; Pineau, J.-P.; Poinsignon, J.; Popa, V.; Pradier, T.; Racca, C.; Randazzo, N.; van Randwijk, J.; Real, D.; Regnier, M.; van Rens, B.; Réthoré, F.; Rewiersma, P.; Riccobene, G.; Rigaud, V.; Ripani, M.; Roca, V.; Roda, C.; Rolin, J. F.; Rostovtsev, A.; Roux, J.; Ruppi, M.; Russo, G. V.; Rusydi, G.; Salesa, F.; Salomon, K.; Sapienza, P.; Schmitt, F.; Schuller, J.-P.; Shanidze, R.; Sokalski, I.; Spona, T.; Spurio, M.; van der Steenhoven, G.; Stolarczyk, T.; Streeb, K.; Sulak, L.; Taiuti, M.; Tamburini, C.; Tao, C.; Tasca, L.; Terreni, G.; Urbano, F.; Valdy, P.; Valente, V.; Vallage, B.; Vaudaine, G.; Venekamp, G.; Verlaat, B.; Vernin, P.; van Wijk, R.; Wijnker, G.; Wobbe, G.; de Wolf, E.; Yao, A.-F.; Zaborov, D.; Zaccone, H.; Zornoza, J. D.; Zúñiga, J.
2007-11-01
A full-scale mechanical prototype line was deployed to a depth of 2500 m to test the leak tightness of the electronics containers and the pressure-resistant properties of an electromechanical cable under evaluation for use in the ANTARES deep-sea neutrino telescope. During a month-long immersion study, line parameter data were taken using miniature autonomous data loggers and shore-based optical time domain reflectometry. Details of the mechanical prototype line, the electromechanical cable and data acquisition are presented. Data taken during the immersion study revealed deficiencies in the pressure resistance of the electromechanical cable terminations at the entry points to the electronics containers. The improvements to the termination, which have been integrated into subsequent detection lines, are discussed. The line also allowed deep-sea acoustic measurements with a prototype hydrophone system. The technical setup of this system is described, and the first results of the data analysis are presented.
Recognition memory is modulated by visual similarity.
Yago, Elena; Ishai, Alumit
2006-06-01
We used event-related fMRI to test whether recognition memory depends on visual similarity between familiar prototypes and novel exemplars. Subjects memorized portraits, landscapes, and abstract compositions by six painters with a unique style, and later performed a memory recognition task. The prototypes were presented with new exemplars that were either visually similar or dissimilar. Behaviorally, novel, dissimilar items were detected faster and more accurately. We found activation in a distributed cortical network that included face- and object-selective regions in the visual cortex, where familiar prototypes evoked stronger responses than new exemplars; attention-related regions in parietal cortex, where responses elicited by new exemplars were reduced with decreased similarity to the prototypes; and the hippocampus and memory-related regions in parietal and prefrontal cortices, where stronger responses were evoked by the dissimilar exemplars. Our findings suggest that recognition memory is mediated by classification of novel exemplars as a match or a mismatch, based on their visual similarity to familiar prototypes.
Detection of Zaire ebolavirus in swine: Assay development and optimization.
Pickering, B S; Collignon, B; Smith, G; Marszal, P; Kobinger, G; Weingartl, H M
2018-02-01
Ebolaviruses (family Filoviridae, order Mononegavirales) cause often fatal, haemorrhagic fever in primates including humans. Pigs have been identified as a species susceptible to Reston ebolavirus (RESTV) infection, with indicated transmission to humans in the Philippines; however, their role during Ebola outbreaks in Africa needs to be clarified. To perform surveillance studies, detection of ebolavirus requires a prerequisite validation of viral RNA and antibody detection methods in swine samples. These diagnostic tests also need to be suitable for deployment to low-level containment laboratories. In this study, we developed a set of tests for detection of antibodies against Zaire ebolavirus (EBOV) in swine. Recombinant EBOV nucleoprotein was produced using a baculovirus expression system for indirect ELISA development. Evaluation of this assay was performed using laboratory and field samples, achieving a diagnostic specificity of 99%. Importantly, the indirect ELISA was able to detect antibodies to EBOV at 7 dpi, 3 days earlier than virus neutralization tests (VNT). The format of the VNT in this work was modified to a microtitre plaque reduction neutralization assay (miPRNT) complemented with immunostaining to provide a more rapid and highly specific assay. Finally, a confirmatory immunoblot assay was generated to supplement the indirect ELISA results. © 2017 Her Majesty the Queen in Right of Canada Reproduced with the permission of the Minister of Health and Agriculture, Canadian Food Inspection Agency.
Bender, Kimberly A; DePrince, Anne; Begun, Stephanie; Hathaway, Jessica; Haffejee, Badiah; Schau, Nicholas
2016-03-02
Homeless youth frequently experience victimization, and youth with histories of trauma often fail to detect danger risks, making them vulnerable to subsequent victimization. The current study describes a pilot test of a skills-based intervention designed to improve risk detection among homeless youth through focusing attention to internal, interpersonal, and environmental cues. Youth aged 18 to 21 years (N = 74) were recruited from a shelter and randomly assigned to receive usual case management services or usual services plus a 3-day manualized risk detection intervention. Pretest and posttest interviews assessed youths' risk detection abilities through vignettes describing risky situations and asking youth to identify risk cues present. Separate 2 (intervention vs. control) × 2 (pretest vs. posttest) mixed ANOVAs found significant interaction effects, as intervention youth significantly improved in overall risk detection compared with control youth. Post hoc subgroup analyses found the intervention had a greater effect for youth without previous experiences of indirect victimization than those with previous indirect victimization experiences. © The Author(s) 2016.
Wu, Xin-Lan; Yu, Shu-Juan; Kang, Ke-Ren
2015-03-01
In this study, an indirect competitive enzyme-linked immunoassay (ic-ELISA) based on monoclonal antibody for 4(5)-Methylimidazole (4-MI) detection was described. The artificial antigens were prepared by conjugating bovine serum albumin (BSA) or ovalbumin (OVA) with the hapten of 4-MI. And monoclonal antibody, evaluated by ic-ELISA, was obtained by immunizing BABL/c mice. After optimizing, a standard curve for ic-ELISA detection on 4-MI was obtained with the linear detection range of 0.64-20.48 mg/L. The cross-reactivity (CR) of all the structural analogues of 4-MI was less than 5.62%. The recoveries of 4-MI in caramels detection were ranged from 88.69% to 114.09%, with relative standard deviation (n=3) below 8.07%. The results suggested that the established ic-ELISA is promising for 4-MI commercial detection in caramels. Copyright © 2014 Elsevier Ltd. All rights reserved.
Beam tracking with micromegas & wire chambers in secondary electron detection configuration
NASA Astrophysics Data System (ADS)
Voštinar, M.; Fernández, B.; Pancin, J.; Alvarez, M. A. G.; Chaminade, T.; Damoy, S.; Doré, D.; Drouart, A.; Druillole, F.; Frémont, G.; Kebbiri, M.; Materna, T.; Monmarthe, E.; Panebianco, S.; Papaevangelou, T.; Riallot, M.; Savajols, H.; Spitaels, C.
2013-12-01
The focal plane of S3 (Super Separator Spectrometer), a new experimental area of SPIRAL2 at GANIL, will be used for identification of nuclei, and requires the reconstruction of their trajectories and velocities by the Time Of Flight (TOF) method. Classical tracking detectors used in-beam would generate a lot of angular and energy straggling due to their thickness. One solution is the use of a SED (Secondary Electron Detection), which consists of a thin emissive foil in beam coupled to a low pressure gaseous detector out of the beam, for the detection of secondary electrons ejected from the foil. Moreover, this type of detector can be used for classical beam tracking at low energies, or for example at NFS (GANIL) for the FALSTAFF experiment for the reconstruction of fission fragments trajectories. Several low pressure gaseous detectors such as wire chambers and Micromegas have been constructed and tested since 2008. High counting rate capabilities and good time resolution obtained in previous tests motivated the construction of a new real-size 2D prototype wire chamber and a 2D bulk Micromegas at low pressure. For the first time, spatial resolution of the Micromegas at low pressure (below 20 mbar) in the SED configuration was measured. Different tests have been performed in order to characterize time and spatial properties of both prototypes, giving spatial resolution in the horizontal (X) direction of 0.90(0.02) mm FWHM for the real size prototype and 0.72(0.08) mm FWHM for Micromegas, and a time resolution of ~ 110(25) ps for the real size prototype.
Scintillator tiles read out with silicon photomultipliers
NASA Astrophysics Data System (ADS)
Pooth, O.; Radermacher, T.; Weingarten, S.; Weinstock, L.
2015-10-01
A detector prototype based on a fast plastic scintillator read out with silicon photomultipliers is presented. All studies have been done with cosmic muons and focus on parameter optimization such as coupling the SiPM to the scintillator or wrapping the scintillator with reflective material. The prototype shows excellent results regarding the light-yield and offers a detection efficiency of 99.5% with a signal purity of 99.9% for cosmic muons.
Characterization of a prototype neutron portal monitor detector
NASA Astrophysics Data System (ADS)
Nakhoul, Nabil
The main objective of this thesis is to provide characterization measurements on a prototype neutron portal monitor (NPM) detector constructed at the University of Massachusetts Lowell. NPM detectors are deployed at all United States border crossings and shipping ports to stop the illicit transfer of weapons-grade plutonium (WGPu) into our country. This large prototype detector with its 0.93 square meter face area is based on thermal neutron capture in 6Li as an alternate technology to the current, very expensive, 3He-based NPM. A neutron detection efficiency of 27.5 % is measured with a 252Cf source which has a spontaneous fission neutron spectrum very similar to that of 240Pu in WGPu. Measurements with an intense 137Cs source establish the extreme insensitivity of the prototype NPM to gamma-ray backgrounds with only one additional count registered for 1.1 million incident gamma rays. This detector also has the ability to locate neutron sources to within an angle of a few degrees. Its sensitivity is further demonstrated by discovering in a few-second measurement the presence of a 2 curie PuBe neutron source even at a distance of 95.5 feet. This thesis also covers in considerable detail the design features that give rise to both a high intrinsic neutron detection efficiency and an extreme gamma-ray insensitivity.
DANTi: Detect and Avoid iN The Cockpit
NASA Technical Reports Server (NTRS)
Chamberlain, James; Consiglio, Maria; Munoz, Cesar
2017-01-01
Mid-air collision risk continues to be a concern for manned aircraft operations, especially near busy non-towered airports. The use of Detect and Avoid (DAA) technologies and draft standards developed for unmanned aircraft systems (UAS), either alone or in combination with other collision avoidance technologies, may be useful in mitigating this collision risk for manned aircraft. This paper describes a NASA research effort known as DANTi (DAA iN The Cockpit), including the initial development of the concept of use, a software prototype, and results from initial flight tests conducted with this prototype. The prototype used a single Automatic Dependent Surveillance - Broadcast (ADS-B) traffic sensor and the own aircraft's position, track, heading and air data information, along with NASA-developed DAA software to display traffic alerts and maneuver guidance to manned aircraft pilots on a portable tablet device. Initial flight tests with the prototype showed a successful DANTi proof-of-concept, but also demonstrated that the traffic separation parameter set specified in the RTCA SC-228 Phase I DAA MOPS may generate excessive false alerts during traffic pattern operations. Several parameter sets with smaller separation values were also tested in flight, one of which yielded more timely alerts for the maneuvers tested. Results from this study may further inform future DANTi efforts as well as Phase II DAA MOPS development.
NASA Astrophysics Data System (ADS)
McGuire, N. D.; Ewen, R. J.; de Lacy Costello, B.; Garner, C. E.; Probert, C. S. J.; Vaughan, K.; Ratcliffe, N. M.
2014-06-01
Rapid volatile profiling of stool sample headspace was achieved using a combination of short multi-capillary chromatography column (SMCC), highly sensitive heated metal oxide semiconductor sensor and artificial neural network software. For direct analysis of biological samples this prototype offers alternatives to conventional gas chromatography (GC) detectors and electronic nose technology. The performance was compared to an identical instrument incorporating a long single capillary column (LSCC). The ability of the prototypes to separate complex mixtures was assessed using gas standards and homogenized in house ‘standard’ stool samples, with both capable of detecting more than 24 peaks per sample. The elution time was considerably faster with the SMCC resulting in a run time of 10 min compared to 30 min for the LSCC. The diagnostic potential of the prototypes was assessed using 50 C. difficile positive and 50 negative samples. The prototypes demonstrated similar capability of discriminating between positive and negative samples with sensitivity and specificity of 85% and 80% respectively. C. difficile is an important cause of hospital acquired diarrhoea, with significant morbidity and mortality around the world. A device capable of rapidly diagnosing the disease at the point of care would reduce cases, deaths and financial burden.
McGuire, N D; Ewen, R J; de Lacy Costello, B; Garner, C E; Probert, C S J; Vaughan, K.; Ratcliffe, N M
2016-01-01
Rapid volatile profiling of stool sample headspace was achieved using a combination of short multi-capillary chromatography column (SMCC), highly sensitive heated metal oxide semiconductor (MOS) sensor and artificial neural network (ANN) software. For direct analysis of biological samples this prototype offers alternatives to conventional GC detectors and electronic nose technology. The performance was compared to an identical instrument incorporating a long single capillary column (LSCC). The ability of the prototypes to separate complex mixtures was assessed using gas standards and homogenised in house ‘standard’ stool samples, with both capable of detecting more than 24 peaks per sample. The elution time was considerably faster with the SMCC resulting in a run time of 10 minutes compared to 30 minutes for the LSCC. The diagnostic potential of the prototypes was assessed using 50 C. difficile positive and 50 negative samples. The prototypes demonstrated similar capability of discriminating between positive and negative samples with sensitivity and specificity of 85% and 80% respectively. C. difficile is an important cause of hospital acquired diarrhoea, with significant morbidity and mortality around the world. A device capable of rapidly diagnosing the disease at the point of care would reduce cases, deaths and financial burden. PMID:27212803
A prototype for the PASS Permanent All Sky Survey
NASA Astrophysics Data System (ADS)
Deeg, H. J.; Alonso, R.; Belmonte, J. A.; Horne, K.; Alsubai, K.; Collier Cameron, A.; Doyle, L. R.
2004-10-01
A prototype system for the Permanent All Sky Survey (PASS) project is presented. PASS is a continuous photometric survey of the entire celestial sphere with a high temporal resolution. Its major objectives are the detection of all giant-planet transits (with periods up to some weeks) across stars up to mag 10.5, and to deliver continuously photometry that is useful for the study of any variable stars. The prototype is based on CCD cameras with short focal length optics on a fixed mount. A small dome to house it at Teide Observatory, Tenerife, is currently being constructed. A placement at the antarctic Dome C is also being considered. The prototype will be used for a feasibility study of PASS, to define the best observing strategies, and to perform a detailed characterization of the capabilities and scope of the survey. Afterwards, a first partial sky surveying will be started with it. That first survey may be able to detect transiting planets during its first few hundred hours of operation. It will also deliver a data set around which software modules dealing with the various scientific objectives of PASS will be developed. The PASS project is still in its early phase and teams interested in specific scientific objectives, in providing technical expertise, or in participating with own observations are invited to collaborate.
Remote Leak Detection: Indirect Thermal Technique
NASA Technical Reports Server (NTRS)
Clements, Sandra
2002-01-01
Remote sensing technologies are being considered for efficient, low cost gas leak detection. Eleven specific techniques have been identified for further study and evaluation of several of these is underway. The Indirect Thermal Technique is one of the techniques that is being explored. For this technique, an infrared camera is used to detect the temperature change of a pipe or fitting at the site of a gas leak. This temperature change is caused by the change in temperature of the gas expanding from the leak site. During the 10-week NFFP program, the theory behind the technique was further developed, experiments were performed to determine the conditions for which the technique might be viable, and a proof-of-concept system was developed and tested in the laboratory.
The high energy cosmic-radiation detection (HERD) facility onboard China's Space Station
NASA Astrophysics Data System (ADS)
Zhang, S. N.; Adriani, O.; Albergo, S.; Ambrosi, G.; An, Q.; Bao, T. W.; Battiston, R.; Bi, X. J.; Cao, Z.; Chai, J. Y.; Chang, J.; Chen, G. M.; Chen, Y.; Cui, X. H.; Dai, Z. G.; D'Alessandro, R.; Dong, Y. W.; Fan, Y. Z.; Feng, C. Q.; Feng, H.; Feng, Z. Y.; Gao, X. H.; Gargano, F.; Giglietto, N.; Gou, Q. B.; Guo, Y. Q.; Hu, B. L.; Hu, H. B.; He, H. H.; Huang, G. S.; Huang, J.; Huang, Y. F.; Li, H.; Li, L.; Li, Y. G.; Li, Z.; Liang, E. W.; Liu, H.; Liu, J. B.; Liu, J. T.; Liu, S. B.; Liu, S. M.; Liu, X.; Lu, J. G.; Mazziotta, M. N.; Mori, N.; Orsi, S.; Pearce, M.; Pohl, M.; Quan, Z.; Ryde, F.; Shi, H. L.; Spillantini, P.; Su, M.; Sun, J. C.; Sun, X. L.; Tang, Z. C.; Walter, R.; Wang, J. C.; Wang, J. M.; Wang, L.; Wang, R. J.; Wang, X. L.; Wang, X. Y.; Wang, Z. G.; Wei, D. M.; Wu, B. B.; Wu, J.; Wu, X.; Wu, X. F.; Xia, J. Q.; Xiao, H. L.; Xu, H. H.; Xu, M.; Xu, Z. Z.; Yan, H. R.; Yin, P. F.; Yu, Y. W.; Yuan, Q.; Zha, M.; Zhang, L.; Zhang, L.; Zhang, L. Y.; Zhang, Y.; Zhang, Y. J.; Zhang, Y. L.; Zhao, Z. G.
2014-07-01
The High Energy cosmic-Radiation Detection (HERD) facility is one of several space astronomy payloads of the cosmic lighthouse program onboard China's Space Station, which is planned for operation starting around 2020 for about 10 years. The main scientific objectives of HERD are indirect dark matter search, precise cosmic ray spectrum and composition measurements up to the knee energy, and high energy gamma-ray monitoring and survey. HERD is composed of a 3-D cubic calorimeter (CALO) surrounded by microstrip silicon trackers (STKs) from five sides except the bottom. CALO is made of about 104 cubes of LYSO crystals, corresponding to about 55 radiation lengths and 3 nuclear interaction lengths, respectively. The top STK microstrips of seven X-Y layers are sandwiched with tungsten converters to make precise directional measurements of incoming electrons and gamma-rays. In the baseline design, each of the four side SKTs is made of only three layers microstrips. All STKs will also be used for measuring the charge and incoming directions of cosmic rays, as well as identifying back scattered tracks. With this design, HERD can achieve the following performance: energy resolution of 1% for electrons and gamma-rays beyond 100 GeV, 20% for protons from 100 GeV to 1 PeV; electron/proton separation power better than 10-5; effective geometrical factors of >3 m2sr for electron and diffuse gamma-rays, >2 m2sr for cosmic ray nuclei. R and D is under way for reading out the LYSO signals with optical fiber coupled to image intensified CCD and the prototype of one layer of CALO.
Prototypes and same-gender bias in perceptions of hiring discrimination.
Carlsson, Rickard; Sinclair, Samantha
2018-01-01
The present study investigated the relative importance of two explanations behind perceptions of gender discrimination in hiring: prototypes and same-gender bias. According to the prototype explanation, people perceive an event as discrimination to the extent that it fits their preconceptions of typical discrimination. In contrast, the same-gender bias explanation asserts that people more readily detect discrimination toward members of their own gender. In four experiments (n = 797), women and men made considerably stronger discrimination attributions, and were moderately more discouraged from seeking work, when the victim was female rather than male. Further, a series of regressions analyses showed beliefs in discrimination of women to be moderately correlated with discrimination attributions of female victims, but little added explanatory value of participant gender, stigma consciousness, or feminist identification. The results offer strong support for the prototype explanation.
Dark Matter Limits from Dwarf Spheroidal Galaxies with the HAWC Gamma-Ray Observatory
NASA Astrophysics Data System (ADS)
Albert, A.; Alfaro, R.; Alvarez, C.; Álvarez, J. D.; Arceo, R.; Arteaga-Velázquez, J. C.; Avila Rojas, D.; Ayala Solares, H. A.; Bautista-Elivar, N.; Becerril, A.; Belmont-Moreno, E.; BenZvi, S. Y.; Bernal, A.; Braun, J.; Brisbois, C.; Caballero-Mora, K. S.; Capistrán, T.; Carramiñana, A.; Casanova, S.; Castillo, M.; Cotti, U.; Cotzomi, J.; Coutiño de León, S.; De León, C.; De la Fuente, E.; Diaz Hernandez, R.; Dingus, B. L.; DuVernois, M. A.; Díaz-Vélez, J. C.; Ellsworth, R. W.; Engel, K.; Fiorino, D. W.; Fraija, N.; García-González, J. A.; Garfias, F.; González, M. M.; Goodman, J. A.; Hampel-Arias, Z.; Harding, J. P.; Hernandez, S.; Hernandez-Almada, A.; Hona, B.; Hüntemeyer, P.; Iriarte, A.; Jardin-Blicq, A.; Joshi, V.; Kaufmann, S.; Kieda, D.; Lauer, R. J.; Lennarz, D.; León Vargas, H.; Linnemann, J. T.; Longinotti, A. L.; Longo Proper, M.; Raya, G. Luis; Luna-García, R.; López-Coto, R.; Malone, K.; Marinelli, S. S.; Martinez-Castellanos, I.; Martínez-Castro, J.; Martínez-Huerta, H.; Matthews, J. A.; Miranda-Romagnoli, P.; Moreno, E.; Mostafá, M.; Nellen, L.; Newbold, M.; Nisa, M. U.; Noriega-Papaqui, R.; Pelayo, R.; Pretz, J.; Pérez-Pérez, E. G.; Ren, Z.; Rho, C. D.; Rivière, C.; Rosa-González, D.; Rosenberg, M.; Ruiz-Velasco, E.; Salesa Greus, F.; Sandoval, A.; Schneider, M.; Schoorlemmer, H.; Sinnis, G.; Smith, A. J.; Springer, R. W.; Surajbali, P.; Taboada, I.; Tibolla, O.; Tollefson, K.; Torres, I.; Vianello, G.; Weisgarber, T.; Westerhoff, S.; Wood, J.; Yapici, T.; Younk, P. W.; Zhou, H.
2018-02-01
The High Altitude Water Cherenkov (HAWC) gamma-ray observatory is a wide field of view observatory sensitive to 500 GeV–100 TeV gamma-rays and cosmic rays. It can also perform diverse indirect searches for dark matter annihilation and decay. Among the most promising targets for the indirect detection of dark matter are dwarf spheroidal galaxies. These objects are expected to have few astrophysical sources of gamma-rays but high dark matter content, making them ideal candidates for an indirect dark matter detection with gamma-rays. Here we present individual limits on the annihilation cross section and decay lifetime for 15 dwarf spheroidal galaxies within the field of view, as well as their combined limit. These are the first limits on the annihilation cross section and decay lifetime using data collected with HAWC. We also present the HAWC flux upper limits of the 15 dwarf spheroidal galaxies in half-decade energy bins.
Indirect searches for dark matter with the Fermi large area telescope
Albert, Andrea
2015-03-24
There is overwhelming evidence that non-baryonic dark matter constitutes ~ 27% of the energy density of the Universe. Weakly Interacting Massive Particles (WIMPs) are promising dark matter candidates that may produce γ rays via annihilation or decay detectable by the Fermi Large Area Telescope (LAT). A detection of WIMPs would also indicate the existence of physics beyond the Standard Model. We present recent results from the two cleanest indirect WIMP searches by the Fermi-LAT Collaboration: searches for γ-ray spectral lines and γ-ray emission associated with Milky Way dwarf spheroidal satellite galaxies.
Minding the MeV gap: The indirect detection of low mass dark matter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boddy, Kimberly K.; Kumar, Jason, E-mail: jkumar@hawaii.edu
2016-06-21
We consider the prospects for the indirect detection of low mass dark matter which couples dominantly to quarks. If the center of mass energy is below about 280 MeV, the kinematically allowed final states will be dominated by photons and neutral pions, producing striking signatures at gamma ray telescopes. In fact, an array of new instruments have been proposed, which would greatly improve sensitivity to photons in this energy range. We find that planned instruments can improve on current sensitivity to dark matter models of this type by up to a few orders of magnitude.
Large Area MEMS Based Ultrasound Device for Cancer Detection.
Wodnicki, Robert; Thomenius, Kai; Hooi, Fong Ming; Sinha, Sumedha P; Carson, Paul L; Lin, Der-Song; Zhuang, Xuefeng; Khuri-Yakub, Pierre; Woychik, Charles
2011-08-21
We present image results obtained using a prototype ultrasound array which demonstrates the fundamental architecture for a large area MEMS based ultrasound device for detection of breast cancer. The prototype array consists of a tiling of capacitive Micro-Machined Ultrasound Transducers (cMUTs) which have been flip-chip attached to a rigid organic substrate. The pitch on the cMUT elements is 185 um and the operating frequency is nominally 9 MHz. The spatial resolution of the new probe is comparable to production PZT probes, however the sensitivity is reduced by conditions that should be correctable. Simulated opposed-view image registration and Speed of Sound volume reconstruction results for ultrasound in the mammographic geometry are also presented.
A multisensor system for airborne surveillance of oil pollution
NASA Technical Reports Server (NTRS)
Edgerton, A. T.; Ketchal, R.; Catoe, C.
1973-01-01
The U.S. Coast Guard is developing a prototype airborne oil surveillance system for use in its Marine Environmental Protection Program. The prototype system utilizes an X-band side-looking radar, a 37-GHz imaging microwave radiometer, a multichannel line scanner, and a multispectral low light level system. The system is geared to detecting and mapping oil spills and potential pollution violators anywhere within a 25 nmi range of the aircraft flight track under all but extreme weather conditions. The system provides for false target discrimination and maximum identification of spilled materials. The system also provides an automated detection alarm, as well as a color display to achieve maximum coupling between the sensor data and the equipment operator.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, K.; Itow, Y.; Rott, C., E-mail: koun@stelab.nagoya-u.ac.jp, E-mail: rott@skku.edu, E-mail: itow@stelab.nagoya-u.ac.jp
Dark matter could be captured in the Sun and self-annihilate, giving rise to an observable neutrino flux. Indirect searches for dark matter looking for this signal with neutrino telescopes have resulted in tight constraints on the interaction cross-section of dark matter with ordinary matter. We investigate how robust limits are against astro-physical uncertainties. We study the effect of the velocity distribution of dark matter in our Galaxy on capture rates in the Sun. We investigate four sources of uncertainties: orbital speed of the Sun, escape velocity of dark matter from the halo, dark matter velocity distribution functions and existence ofmore » a dark disc. We find that even extreme cases currently discussed do not decrease the sensitivity of indirect detection significantly because the capture is achieved over a broad range of the velocity distribution by integration over the velocity distribution. The effect of the uncertainty in the high-velocity tail of dark matter halo is very marginal as the capture process is rather inefficient at this region. The difference in capture rate in the Sun for various scenarios is compared to the expected change in event rates for direct detection. The possibility of co-rotating structure with the Sun can largely boost the signal and hence makes the interpretation of indirect detection conservative compared to direct detection.« less
Belle II silicon vertex detector
NASA Astrophysics Data System (ADS)
Adamczyk, K.; Aihara, H.; Angelini, C.; Aziz, T.; Babu, V.; Bacher, S.; Bahinipati, S.; Barberio, E.; Baroncelli, Ti.; Baroncelli, To.; Basith, A. K.; Batignani, G.; Bauer, A.; Behera, P. K.; Bergauer, T.; Bettarini, S.; Bhuyan, B.; Bilka, T.; Bosi, F.; Bosisio, L.; Bozek, A.; Buchsteiner, F.; Casarosa, G.; Ceccanti, M.; Červenkov, D.; Chendvankar, S. R.; Dash, N.; Divekar, S. T.; Doležal, Z.; Dutta, D.; Enami, K.; Forti, F.; Friedl, M.; Hara, K.; Higuchi, T.; Horiguchi, T.; Irmler, C.; Ishikawa, A.; Jeon, H. B.; Joo, C. W.; Kandra, J.; Kang, K. H.; Kato, E.; Kawasaki, T.; Kodyš, P.; Kohriki, T.; Koike, S.; Kolwalkar, M. M.; Kvasnička, P.; Lanceri, L.; Lettenbicher, J.; Maki, M.; Mammini, P.; Mayekar, S. N.; Mohanty, G. B.; Mohanty, S.; Morii, T.; Nakamura, K. R.; Natkaniec, Z.; Negishi, K.; Nisar, N. K.; Onuki, Y.; Ostrowicz, W.; Paladino, A.; Paoloni, E.; Park, H.; Pilo, F.; Profeti, A.; Rashevskaya, I.; Rao, K. K.; Rizzo, G.; Rozanska, M.; Sandilya, S.; Sasaki, J.; Sato, N.; Schultschik, S.; Schwanda, C.; Seino, Y.; Shimizu, N.; Stypula, J.; Suzuki, J.; Tanaka, S.; Tanida, K.; Taylor, G. N.; Thalmeier, R.; Thomas, R.; Tsuboyama, T.; Uozumi, S.; Urquijo, P.; Vitale, L.; Volpi, M.; Watanuki, S.; Watson, I. J.; Webb, J.; Wiechczynski, J.; Williams, S.; Würkner, B.; Yamamoto, H.; Yin, H.; Yoshinobu, T.; Belle II SVD Collaboration
2016-09-01
The Belle II experiment at the SuperKEKB collider in Japan is designed to indirectly probe new physics using approximately 50 times the data recorded by its predecessor. An accurate determination of the decay-point position of subatomic particles such as beauty and charm hadrons as well as a precise measurement of low-momentum charged particles will play a key role in this pursuit. These will be accomplished by an inner tracking device comprising two layers of pixelated silicon detector and four layers of silicon vertex detector based on double-sided microstrip sensors. We describe herein the design, prototyping and construction efforts of the Belle-II silicon vertex detector.
Bertz, Steven H; Hardin, Richard A; Heavey, Thomas J; Jones, Daniel S; Monroe, T Blake; Murphy, Michael D; Ogle, Craig A; Whaley, Tara N
2013-07-29
Grow slow: The usual direct treatment of MeLi and CuSPh did not yield X-ray quality crystals of MeCu(SPh)Li. An indirect method starting from Me2CuLi⋅LiSPh and chalcone afforded the desired crystals by the slow reaction of the intermediate π-complex (see scheme). This strategy produced the first X-ray crystal structure of a Posner cuprate. A complementary NMR study showed that the contact ion pair was also the main species in solution. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ching, W.-M.; Wang, H.; Eamsila, C.; Kelly, D. J.; Dasch, G. A.
1998-01-01
The variable 56-kDa major outer membrane protein of Orientia tsutsugamushi is the immunodominant antigen in human scrub typhus infections. The gene encoding this protein from Karp strain was cloned into the expression vector pET11a. The recombinant protein (r56) was expressed as a truncated nonfusion protein (amino acids 80 to 456 of the open reading frame) which formed an inclusion body when expressed in Escherichia coli BL21. Refolded r56 was purified and compared to purified whole-cell lysate of the Karp strain of O. tsutsugamushi by immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) for reactivity with rabbit sera prepared against eight antigenic prototypes of O. tsutsugamushi as well as several other species of Rickettsiales and nonrickettsial antigens. Refolded r56 exhibited broad reactivity with the rabbit antisera against the Orientia prototypes, and the ELISA reactions with the r56 and Karp whole-cell lysate antigens correlated well (r = 0.81, n = 22, sensitivity compared to that of standard ELISA of 91%). Refolded r56 did not react with most antisera against other rickettsial species or control antigens (specificity = 92%, n = 13) using a positive cutoff value determined with eight uninfected rabbit sera. Refolded r56 was evaluated further by ELISA, using 128 sera obtained from patients with suspected scrub typhus from Korat, Thailand, and 74 serum specimens from healthy Thai soldiers. By using the indirect immunoperoxidase assay as the reference assay, the recombinant antigen exhibited a sensitivity and specificity of 93% or greater for detection of both IgG and IgM in the ELISA at 1:400 serum dilution. These results strongly suggest that purified r56 is a suitable candidate for replacing the density gradient-purified, rickettsia-derived, whole-cell antigen currently used in the commercial dipstick assay available in the United States. PMID:9665960
Ching, W M; Wang, H; Eamsila, C; Kelly, D J; Dasch, G A
1998-07-01
The variable 56-kDa major outer membrane protein of Orientia tsutsugamushi is the immunodominant antigen in human scrub typhus infections. The gene encoding this protein from Karp strain was cloned into the expression vector pET11a. The recombinant protein (r56) was expressed as a truncated nonfusion protein (amino acids 80 to 456 of the open reading frame) which formed an inclusion body when expressed in Escherichia coli BL21. Refolded r56 was purified and compared to purified whole-cell lysate of the Karp strain of O. tsutsugamushi by immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) for reactivity with rabbit sera prepared against eight antigenic prototypes of O. tsutsugamushi as well as several other species of Rickettsiales and nonrickettsial antigens. Refolded r56 exhibited broad reactivity with the rabbit antisera against the Orientia prototypes, and the ELISA reactions with the r56 and Karp whole-cell lysate antigens correlated well (r = 0.81, n = 22, sensitivity compared to that of standard ELISA of 91%). Refolded r56 did not react with most antisera against other rickettsial species or control antigens (specificity = 92%, n = 13) using a positive cutoff value determined with eight uninfected rabbit sera. Refolded r56 was evaluated further by ELISA, using 128 sera obtained from patients with suspected scrub typhus from Korat, Thailand, and 74 serum specimens from healthy Thai soldiers. By using the indirect immunoperoxidase assay as the reference assay, the recombinant antigen exhibited a sensitivity and specificity of 93% or greater for detection of both IgG and IgM in the ELISA at 1:400 serum dilution. These results strongly suggest that purified r56 is a suitable candidate for replacing the density gradient-purified, rickettsia-derived, whole-cell antigen currently used in the commercial dipstick assay available in the United States.
Brito Palma, Bernardo; Fisher, Charles W; Rueff, José; Kranendonk, Michel
2016-05-16
The formation of reactive metabolites through biotransformation is the suspected cause of many adverse drug reactions. Testing for the propensity of a drug to form reactive metabolites has increasingly become an integral part of lead-optimization strategy in drug discovery. DNA reactivity is one undesirable facet of a drug or its metabolites and can lead to increased risk of cancer and reproductive toxicity. Many drugs are metabolized by cytochromes P450 in the liver and other tissues, and these reactions can generate hard electrophiles. These hard electrophilic reactive metabolites may react with DNA and may be detected in standard in vitro genotoxicity assays; however, the majority of these assays fall short due to the use of animal-derived organ extracts that inadequately represent human metabolism. The current study describes the development of bacterial systems that efficiently detect DNA-damaging electrophilic reactive metabolites generated by human P450 biotransformation. These assays use a GFP reporter system that detects DNA damage through induction of the SOS response and a GFP reporter to control for cytotoxicity. Two human CYP1A2-competent prototypes presented here have appropriate characteristics for the detection of DNA-damaging reactive metabolites in a high-throughput manner. The advantages of this approach include a short assay time (120-180 min) with real-time measurement, sensitivity to small amounts of compound, and adaptability to a microplate format. These systems are suitable for high-throughput assays and can serve as prototypes for the development of future enhanced versions.
Spectral-Based Volume Sensor Prototype, Post-VS4 Test Series Algorithm Development
2009-04-30
Computer Pcorr Probabilty / Percentage of Correct Classification (# Correct / # Total) PD PhotoDiode Pd Probabilty / Percentage of Detection (# Correct...Detections / Total of Sources) Pfa Probabilty / Percentage of False Alarm (# FAs / Total # of Sources) SBVS Spectral-Based Volume Sensor SFA Smoke and
Assistive obstacle detection and navigation devices for vision-impaired users.
Ong, S K; Zhang, J; Nee, A Y C
2013-09-01
Quality of life for the visually impaired is an urgent worldwide issue that needs to be addressed. Obstacle detection is one of the most important navigation tasks for the visually impaired. In this research, a novel range sensor placement scheme is proposed in this paper for the development of obstacle detection devices. Based on this scheme, two prototypes have been developed targeting at different user groups. This paper discusses the design issues, functional modules and the evaluation tests carried out for both prototypes. Implications for Rehabilitation Visual impairment problem is becoming more severe due to the worldwide ageing population. Individuals with visual impairment require assistance from assistive devices in daily navigation tasks. Traditional assistive devices that assist navigation may have certain drawbacks, such as the limited sensing range of a white cane. Obstacle detection devices applying the range sensor technology can identify road conditions with a higher sensing range to notify the users of potential dangers in advance.
Design and evaluation of the ReKon : an integrated detection and assessment perimeter system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dabling, Jeffrey Glenn; Andersen, Jason Jann; McLaughlin, James O.
2013-02-01
Kontek Industries (Kannapolis, NC) and their subsidiary, Stonewater Control Systems (Kannapolis, NC), have entered into a cooperative research and development agreement with Sandia to jointly develop and evaluate an integrated perimeter security system solution, one that couples access delay with detection and assessment. This novel perimeter solution was designed to be configurable for use at facilities ranging from high-security military sites to commercial power plants, to petro/chemical facilities of various kinds. A prototype section of the perimeter has been produced and installed at the Sandia Test and Evaluation Center in Albuquerque, NM. This prototype system integrated fiber optic break sensors,more » active infrared sensors, fence disturbance sensors, video motion detection, and ground sensors. This report documents the design, testing, and performance evaluation of the developed ReKon system. The ability of the system to properly detect pedestrian or vehicle attempts to bypass, breach, or otherwise defeat the system is characterized, as well as the Nuisance Alarm Rate.« less
Decadal trends in marine reserves reveal differential rates of change in direct and indirect effects
Babcock, R.C.; Shears, N.T.; Alcala, A.C.; Barrett, N.S.; Edgar, G.J.; Lafferty, K.D.; McClanahan, T.R.; Russ, G.R.
2010-01-01
Decadal-scale observations of marine reserves suggest that indirect effects on taxa that occur through cascading trophic interactions take longer to develop than direct effects on target species. Combining and analyzing a unique set of long-term time series of ecologic data in and out of fisheries closures from disparate regions, we found that the time to initial detection of direct effects on target species (+ or -SE) was 5.13 + or - 1.9 years, whereas initial detection of indirect effects on other taxa, which were often trait mediated, took significantly longer (13.1 + or - 2.0 years). Most target species showed initial direct effects, but their trajectories over time were highly variable. Many target species continued to increase, some leveled off, and others decreased. Decreases were due to natural fluctuations, fishing impacts from outside reserves, or indirect effects from target species at higher trophic levels. The average duration of stable periods for direct effects was 6.2 + or - 1.2 years, even in studies of more than 15 years. For indirect effects, stable periods averaged 9.1 + or - 1.6 years, although this was not significantly different from direct effects. Populations of directly targeted species were more stable in reserves than in fished areas, suggesting increased ecologic resilience. This is an important benefit of marine reserves with respect to their function as a tool for conservation and restoration.
Babcock, R C; Shears, N T; Alcala, A C; Barrett, N S; Edgar, G J; Lafferty, K D; McClanahan, T R; Russ, G R
2010-10-26
Decadal-scale observations of marine reserves suggest that indirect effects on taxa that occur through cascading trophic interactions take longer to develop than direct effects on target species. Combining and analyzing a unique set of long-term time series of ecologic data in and out of fisheries closures from disparate regions, we found that the time to initial detection of direct effects on target species (±SE) was 5.13 ± 1.9 years, whereas initial detection of indirect effects on other taxa, which were often trait mediated, took significantly longer (13.1 ± 2.0 years). Most target species showed initial direct effects, but their trajectories over time were highly variable. Many target species continued to increase, some leveled off, and others decreased. Decreases were due to natural fluctuations, fishing impacts from outside reserves, or indirect effects from target species at higher trophic levels. The average duration of stable periods for direct effects was 6.2 ± 1.2 years, even in studies of more than 15 years. For indirect effects, stable periods averaged 9.1 ± 1.6 years, although this was not significantly different from direct effects. Populations of directly targeted species were more stable in reserves than in fished areas, suggesting increased ecologic resilience. This is an important benefit of marine reserves with respect to their function as a tool for conservation and restoration.
Acoustic leak-detection system for railroad transportation security
NASA Astrophysics Data System (ADS)
Womble, P. C.; Spadaro, J.; Harrison, M. A.; Barzilov, A.; Harper, D.; Hopper, L.; Houchins, E.; Lemoff, B.; Martin, R.; McGrath, C.; Moore, R.; Novikov, I.; Paschal, J.; Rogers, S.
2007-04-01
Pressurized rail tank cars transport large volumes of volatile liquids and gases throughout the country, much of which is hazardous and/or flammable. These gases, once released in the atmosphere, can wreak havoc with the environment and local populations. We developed a system which can non-intrusively and non-invasively detect and locate pinhole-sized leaks in pressurized rail tank cars using acoustic sensors. The sound waves from a leak are produced by turbulence from the gas leaking to the atmosphere. For example, a 500 μm hole in an air tank pressurized to 689 kPa produces a broad audio frequency spectrum with a peak near 40 kHz. This signal is detectable at 10 meters with a sound pressure level of 25 dB. We are able to locate a leak source using triangulation techniques. The prototype of the system consists of a network of acoustic sensors and is located approximately 10 meters from the center of the rail-line. The prototype has two types of acoustic sensors, each with different narrow frequency response band: 40 kHz and 80 kHz. The prototype is connected to the Internet using WiFi (802.11g) transceiver and can be remotely operated from anywhere in the world. The paper discusses the construction, operation and performance of the system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jensen, Erik
In this successful SBIR Phase II effort, HJ Science & Technology, Inc. has designed and built a novel portable instrument capable of performing automated aqueous organochloride (chlorinated solvent) speciation analysis for environmental monitoring at DoE sites. Our technique employs performing organochloride conjugation, labeling the conjugate with an efficient fluorophore, and performing on-chip capillary electrophoresis separation with laser induced fluorescence detection. The key component of the portable instrument is a novel microfluidic chip capable of complete “end-to-end” automation of sample preparation, conjugation, labeling, and μCE separation and detection. In addition, the Phase II prototype includes key supporting instrumentation such as themore » optical module, pneumatic manifold, electronics, software, etc. As such, we have achieved all of the following 4 Phase II technical objectives: 1) Further refine and optimize the “on-chip” automation of the organochloride conjugation and labeling protocol, 2) Further improve the microfluidic chip fabrication process and the pneumatic manifold design in order to address issues related to performance consistency, product yield, performance reliability, and user friendliness, 3) Design and build the supporting components of the Phase II prototype including optical module, electronics, and software, and 4) Assemble the Phase II prototype hardware.« less
A passive infrared ice detection technique for helicopter applications
NASA Technical Reports Server (NTRS)
Dershowitz, Adam L.; Hansman, R. John, Jr.
1991-01-01
A technique has been developed, and successfully tested, to detect icing remotely on helicopter rotor blades. Using passive infrared (IR) thermometry it is possible to detect the warming caused by latent heat released as supercooled water freezes. During icing, the ice accretion region on the leading edge of the blade is found to be warmer than the uniced trailing edge resulting in a chordwise temperature profile characteristic of icing. Preliminary tests, using an IR Thermal video system, were conducted on a static model in the NASA Icing Research Tunnel (IRT) for a variety of wet (glaze) and dry (rime) ice conditions. A prototype detector system was built consisting of a single point IR pyrometer, and experiments were run on a small scale rotor model. Using this prototype detector, the characteristic chordwise temperature profiles were again observed for a range of icing conditions. Several signal processing methods were investigated, to allow automatic recognition of the icing signature. Additionally, several implementation issues were considered. Based on both the static and subscale rotor tests, where ice was successfully detected, the passive IR technique appears to be promising for rotor ice detection.
DAMPE prototype and its beam test results at CERN
NASA Astrophysics Data System (ADS)
Wu, Jian; Hu, Yiming; Chang, Jin
The first Chinese high energy cosmic particle detector(DAMPE) aims to detect electron/gamma at the range between 5GeV and 10TeV in space. A prototype of this detector is made and tested using both cosmic muons and test beam at CERN. Energy and space resolution as well as strong separation power for electron and proton are shown in the results. The detector structure is illustrated as well.
Wearable Wireless Sensor for Multi-Scale Physiological Monitoring
2015-10-01
clothes with different colors and patterns. The developed algorithm can still detect the chest movements even if single color clothes are worn...Distribution Unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT One of the aims of Year 2 of the project was to complete development of a prototype multi...this aim, we have developed a prototype 6-photodetector reflectance-based pulse oximeter and results to date show that good signals can be obtained in
Gaze Direction Detection in Autism Spectrum Disorder
ERIC Educational Resources Information Center
Forgeot d'Arc, Baudouin; Delorme, Richard; Zalla, Tiziana; Lefebvre, Aline; Amsellem, Frédérique; Moukawane, Sanaa; Letellier, Laurence; Leboyer, Marion; Mouren, Marie-Christine; Ramus, Franck
2017-01-01
Detecting where our partners direct their gaze is an important aspect of social interaction. An atypical gaze processing has been reported in autism. However, it remains controversial whether children and adults with autism spectrum disorder interpret indirect gaze direction with typical accuracy. This study investigated whether the detection of…
A quantum dot-based immunoassay for screening of tylosin and tilmicosin in edible animal tissues.
Le, Tao; Zhu, Liqian; Yang, Xian
2015-01-01
A rapid, indirect competitive fluorescence-linked immunosorbent assay (ic-FLISA) based on quantum dots (QDs) as the fluorescent marker was developed for the detection of tylosin and tilmicosin in edible animal tissues. The end point fluorescent detection system was carried out using QDs conjugated with goat anti-mouse secondary antibody. The limits of detection (LODs) for the determination of tylosin and tilmicosin were 0.02 and 0.04 μg kg(-1), respectively. This detection method was used to analyse spiked samples and the recoveries ranged from 83.5% to 98.7% for tylosin and from 81.8% to 98.2% for tilmicosin. In real porcine tissue sample analysis, the results of ic-FLISA were similar to those obtained from an indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) to an HPLC method indicating its potential for tylosin and tilmicosin screening in edible animal tissues.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thornton, Michelle
Capillary electrophoresis (CE) is an effective method for separating ionic species according to differences in their electrophoretic mobilities. CE separations of amino acids by direct detection are difficult due to their similar electrophoretic mobilities and low absorbances. However, native amino acids can be separated by CE as cations at a low pH by adding an alkanesulfonic acid to the electrolyte carrier which imparts selectivity to the system. Derivatization is unnecessary when direct UV detection is used at 185 nm. Simultaneous speciation of metal cations such as vanadium (IV) and vanadium (V) can easily be performed without complexation prior to analysis.more » An indirect UV detection scheme for acidic conditions was also developed using guanidine as the background carrier electrolyte (BCE) for the indirect detection of metal cations. Three chapters have been removed for separate processing. This report contains introductory material, references, and general conclusions. 80 refs.« less
Remote detection of chem/bio hazards via coherent anti-Stokes Raman spectroscopy
2017-09-12
hour per response, including the time for reviewing lnstnJctions, searching existing data sources, gathering and maintaining the data needed, and... time remote detection of hazardous microparticles in atmosphere and to evaluate the range of distances for typical species and the parameters of laser...detectable photons from a prototype molecule at a distance. 1S. SUBJECT TERMS Stimulated Raman scattering, Remote detection, biochemical agents, explosives
[Study on serological cross-reactivity of six pathogenic phleboviruses].
Wu, Wei; Zhang, Shuo; Zhang, Quan-Fu; Li, Chuan; Liang, Mi-Fang; Li, De-Xin
2014-07-01
This article aimed to study the antigenicity of nucleocapsid proteins (NPs) in six pathogenic phleboviruses and to provide theoretical evidence for the development of serological diagnostic reagents. NPs of six pathogenic phleboviruses were expressed and purified using a prokaryotic expression system and rabbits were immunized with individual recombinant NPs. Cross-reactions among NPs and rabbit sera were determined by both indirect ELISA and Western blotting analyses, and the sera titer was determined by indirect ELISA. Furthermore, sera from SFTS patients were also detected by each recombinant NP as a coating antigen using indirect ELISA. The cross-reactions and the sera titer were subsequently determined. Both the concentration and purity of recombinant NPs of six pathogenic phleboviruses met the standards for immunization and detection. The results of indirect ELISA and Western blotting showed that each anti-phlebovirus NP rabbit immune serum had potential serological cross-reactivity with the other five virus NP antigens. Furthermore, the sera from SFTS patients also had cross-reactivity with the other five NP antigens to a certain extent. Our preliminary study evaluated the antigenicity and immune reactivity of six pathogenic phleboviruses NPs and laid the foundation for the development of diagnostic reagents.
Indirect Competitive Enzyme-Linked Immunosorbent Assay (ELISA).
Kohl, Thomas O; Ascoli, Carl A
2017-07-05
The indirect competitive ELISA (indirect cELISA) pits plate-immobilized antigen against antigens in solution for binding to antigen-specific antibody. The antigens in solution are in the test sample and are first incubated with antigen-specific antibody. These antibody-antigen complexes are then added to microtiter plates whose wells have been coated with purified antigen. The wells are washed to remove unbound antigen-antibody complexes and free antigen. A reporter-labeled secondary antibody is then added followed by the addition of substrate. Substrate hydrolysis yields a signal that is inversely proportional to antigen concentration within the sample. This is because when antigen concentration is high in the test sample, most of the antibody is bound before adding the solution to the plate. Most of the antibody remains in solution (as complexes) and is thus washed away before the addition of the reporter-labeled secondary antibody and substrate. Thus, the higher the antigen concentration in the test sample, the weaker the resultant signal in the detection step. The indirect cELISA is often used for competitive detection and quantification of antibodies against viral diseases in biological samples. © 2017 Cold Spring Harbor Laboratory Press.
NASA Technical Reports Server (NTRS)
Smith, Alphonso C.
1998-01-01
Fabry-Perot Interferometer (FPI) sensor detection system was continued and refined modifications were made in the data acquisition and evaluation process during the last year. The ultrasonic and FPI detection system was improved from one to multiple sensor detectors. Physical models were developed to understand the physical phenomenon of this work. Multilayered flawed samples were fabricated for inspection by a prototype ultrasonic and FPI detection. Experimental data was verified with simulated results. Undergraduate students that were associated with this research gained valuable knowledge from this experience. This was a learning process helping students to understand the importance of research and its application to solve important technological problems. As a result of our students exposure to this research two and planning to continue this type of research work in graduate school. A prototype instrument package was laboratory tested an actual airframe structure for documentation purposes.
Ubiquitous health monitoring and real-time cardiac arrhythmias detection: a case study.
Li, Jian; Zhou, Haiying; Zuo, Decheng; Hou, Kun-Mean; De Vaulx, Christophe
2014-01-01
As the symptoms and signs of heart diseases that cause sudden cardiac death, cardiac arrhythmia has attracted great attention. Due to limitations in time and space, traditional approaches to cardiac arrhythmias detection fail to provide a real-time continuous monitoring and testing service applicable in different environmental conditions. Integrated with the latest technologies in ECG (electrocardiograph) analysis and medical care, the pervasive computing technology makes possible the ubiquitous cardiac care services, and thus brings about new technical challenges, especially in the formation of cardiac care architecture and realization of the real-time automatic ECG detection algorithm dedicated to care devices. In this paper, a ubiquitous cardiac care prototype system is presented with its architecture framework well elaborated. This prototype system has been tested and evaluated in all the clinical-/home-/outdoor-care modes with a satisfactory performance in providing real-time continuous cardiac arrhythmias monitoring service unlimitedly adaptable in time and space.
An optical sensor for detecting the contact location of a gas-liquid interface on a body.
Belden, Jesse; Jandron, Michael
2014-08-01
An optical sensor for detecting the dynamic contact location of a gas-liquid interface along the length of a body is described. The sensor is developed in the context of applications to supercavitating bodies requiring measurement of the dynamic cavity contact location; however, the sensing method is extendable to other applications as well. The optical principle of total internal reflection is exploited to detect changes in refractive index of the medium contacting the body at discrete locations along its length. The derived theoretical operation of the sensor predicts a signal attenuation of 18 dB when a sensed location changes from air-contacting to water-contacting. Theory also shows that spatial resolution (d) scales linearly with sensor length (L(s)) and a resolution of 0.01L(s) can be achieved. A prototype sensor is constructed from simple components and response characteristics are quantified for different ambient light conditions as well as partial wetting states. Three methods of sensor calibration are described and a signal processing framework is developed that allows for robust detection of the gas-liquid contact location. In a tank draining experiment, the prototype sensor resolves the water level with accuracy limited only by the spatial resolution, which is constrained by the experimental setup. A more representative experiment is performed in which the prototype sensor accurately measures the dynamic contact location of a gas cavity on a water tunnel wall.
Development of an Electronic Kit for detecting asthma in Human Respiratory System
NASA Astrophysics Data System (ADS)
Shek Hong, Cheow; Ghani, Ahmad Shahrizan Abdul; Khairuddin, Ismail Mohd
2018-03-01
In this paper, a prototype of a carbon dioxide (CO2) measurement device is designed to detect and used to monitor asthma patients. Nowadays, capnogram device is widely used in monitoring asthma and asthma related medical services. However, capnogram is very costly and unaffordable for patient especially those who are in low income household. Thus, the proposed device is cost effective, affordable, and produced to detect and monitor the severity of asthma. Meanwhile, flow meter will cause patient to have chest pain as they needed maximum effort to blow in the device. To overcome these limitations, this prototype electronic kit is easy to use and suitable for all range patients. This prototype electronic kit consists of MH-Z14A carbon dioxide (CO2) sensor to detect the concentration of carbon dioxide from the user exhaled air. Arduino microcontroller is used to process the data while TFT Display shield is applied for data presentation. In addition, HC-06 Bluetooth module is used to communicate with PC for further analysis of the captured graph. This device was tested with 3 asthmatics and 3 normal users. The results showed that asthmatic user has a different graph pattern compared with normal user and these graphs are clearly differentiated on the device TFT screen. Asthmatic user produces “shark fin”-like pattern whereas normal user produces “square wave”-like pattern. This device has successfully produced distinguished-patterns difference between asthmatic and normal user; therefore, it is suitable for asthma monitoring.
Ultrasonic corona sensor study
NASA Technical Reports Server (NTRS)
Harrold, R. T.
1976-01-01
The overall objective of this program is to determine the feasibility of using ultrasonic (above 20 kHz) corona detection techniques to detect low order (non-arcing) coronas in varying degrees of vacuum within large high vacuum test chambers, and to design, fabricate, and deliver a prototype ultrasonic corona sensor.
NASA Astrophysics Data System (ADS)
Abazov, Victor; Alexeev, Gennady; Alexeev, Maxim; Frolov, Vladimir; Golovanov, Georgy; Kutuzov, Sergey; Piskun, Alexei; Samartsev, Alexander; Tokmenin, Valeri; Verkheev, Alexander; Vertogradov, Leonid; Zhuravlev, Nikolai
2018-04-01
The
The cosmic ray muon tomography facility based on large scale MRPC detectors
NASA Astrophysics Data System (ADS)
Wang, Xuewu; Zeng, Ming; Zeng, Zhi; Wang, Yi; Zhao, Ziran; Yue, Xiaoguang; Luo, Zhifei; Yi, Hengguan; Yu, Baihui; Cheng, Jianping
2015-06-01
Cosmic ray muon tomography is a novel technology to detect high-Z material. A prototype of TUMUTY with 73.6 cm×73.6 cm large scale position sensitive MRPC detectors has been developed and is introduced in this paper. Three test kits have been tested and image is reconstructed using MAP algorithm. The reconstruction results show that the prototype is working well and the objects with complex structure and small size (20 mm) can be imaged on it, while the high-Z material is distinguishable from the low-Z one. This prototype provides a good platform for our further studies of the physical characteristics and the performances of cosmic ray muon tomography.
A prototype home robot with an ambient facial interface to improve drug compliance.
Takacs, Barnabas; Hanak, David
2008-01-01
We have developed a prototype home robot to improve drug compliance. The robot is a small mobile device, capable of autonomous behaviour, as well as remotely controlled operation via a wireless datalink. The robot is capable of face detection and also has a display screen to provide facial feedback to help motivate patients and thus increase their level of compliance. An RFID reader can identify tags attached to different objects, such as bottles, for fluid intake monitoring. A tablet dispenser allows drug compliance monitoring. Despite some limitations, experience with the prototype suggests that simple and low-cost robots may soon become feasible for care of people living alone or in isolation.
Two-Dimensional and Three-Dimensional Ultrasound of Artificial Skin.
Wortsman, Ximena; Navarrete, Nelson
2017-01-01
Wound healing may be a difficult problem, and variable types of artificial skin prototypes have been developed for supporting this process. Using ultrasound, we studied 4 cellulose-derived artificial skin prototypes and assessed their two-dimensional and three-dimensional morphology. These prototypes were identified on ultrasound both on in vitro and in vivo studies. They allowed the sonographic observation of deeper layers on different types of surfaces of the body with good definition on the in vivo examinations performed on healthy skin and cutaneous ulcers. The ultrasound detection of these artificial biomaterials may potentially support the noninvasive monitoring of wound healing. © 2016 by the American Institute of Ultrasound in Medicine.
Cho, Hyo-Min; Ding, Huanjun; Barber, William C; Iwanczyk, Jan S; Molloi, Sabee
2015-07-01
To investigate the feasibility of detecting breast microcalcification (μCa) with a dedicated breast computed tomography (CT) system based on energy-resolved photon-counting silicon (Si) strip detectors. The proposed photon-counting breast CT system and a bench-top prototype photon-counting breast CT system were simulated using a simulation package written in matlab to determine the smallest detectable μCa. A 14 cm diameter cylindrical phantom made of breast tissue with 20% glandularity was used to simulate an average-sized breast. Five different size groups of calcium carbonate grains, from 100 to 180 μm in diameter, were simulated inside of the cylindrical phantom. The images were acquired with a mean glandular dose (MGD) in the range of 0.7-8 mGy. A total of 400 images was used to perform a reader study. Another simulation study was performed using a 1.6 cm diameter cylindrical phantom to validate the experimental results from a bench-top prototype breast CT system. In the experimental study, a bench-top prototype CT system was constructed using a tungsten anode x-ray source and a single line 256-pixels Si strip photon-counting detector with a pixel pitch of 100 μm. Calcium carbonate grains, with diameter in the range of 105-215 μm, were embedded in a cylindrical plastic resin phantom to simulate μCas. The physical phantoms were imaged at 65 kVp with an entrance exposure in the range of 0.6-8 mGy. A total of 500 images was used to perform another reader study. The images were displayed in random order to three blinded observers, who were asked to give a 4-point confidence rating on each image regarding the presence of μCa. The μCa detectability for each image was evaluated by using the average area under the receiver operating characteristic curve (AUC) across the readers. The simulation results using a 14 cm diameter breast phantom showed that the proposed photon-counting breast CT system can achieve high detection accuracy with an average AUC greater than 0.89 ± 0.07 for μCas larger than 120 μm in diameter at a MGD of 3 mGy. The experimental results using a 1.6 cm diameter breast phantom showed that the prototype system can achieve an average AUC greater than 0.98 ± 0.01 for μCas larger than 140 μm in diameter using an entrance exposure of 1.2 mGy. The proposed photon-counting breast CT system based on a Si strip detector can potentially offer superior image quality to detect μCa with a lower dose level than a standard two-view mammography.
Direct Detection of The Lyman Continuum of Star-forming Galaxies at z~3
NASA Astrophysics Data System (ADS)
Vasei, Kaveh; Siana, Brian; Shapley, Alice; Alavi, Anahita; Rafelski, Marc
2018-01-01
Star-forming galaxies are widely believed to be responsible for the reionization of the Universe and much of the ionizing background at z>3. Therefore, there has been much interest in quantifying the escape fraction of the Lyman continuum (LyC) radiation of the star-forming galaxies. Yet direct detection of LyC has proven to be exceptionally challenging. Despite numerous efforts only 7 galaxies at z<2 (all with escape fractions less than 0.04) and 3 galaxies at z>2 have been robustly confirmed as LyC leakers. To avoid these challenges many studies use indirect methods to infer the LyC escape fraction. We tested these indirect methods by attempting to detect escaping LyC with a 10-orbit Hubble near-UV (F275W) image that is just below the Lyman limit at the redshift of the Cosmic Horseshoe (a lensed galaxy at z=2.4). We concluded that the measured escape fraction is lower, by more than a factor of five, than the expected escape fraction based on the indirect methods. This emphasizes that indirect determinations should only be interpreted as upper-limits. We also investigated the deepest near-UV Hubble images of the SSA22 field to detect LyC leakage from a large sample of candidate star-forming galaxies at z~3.1, whose redshift was obtained by deep Keck/LRIS spectroscopy and for which Keck narrow-band imaging was showing possible LyC leakage. The high spatial resolution of Hubble images is crucial to confirm our detections are clean from foreground contaminating galaxies, and also to ascertain the escape fraction of our final candidates. We identify five clean LyC emitting star-forming galaxies. The follow up investigation of these galaxies will significantly increase our knowledge of the LyC escape fraction and the mechanisms allowing for LyC escape.
The Full-Scale Prototype for the Fluorescence Detector Array of Single-Pixel Telescopes
NASA Astrophysics Data System (ADS)
Fujii, T.; Malacari, M.; Bellido, J. A.; Farmer, J.; Galimova, A.; Horvath, P.; Hrabovsky, M.; Mandat, D.; Matalon, A.; Matthews, J. N.; Merolle, M.; Ni, X.; Nozka, L.; Palatka, M.; Pech, M.; Privitera, P.; Schovanek, P.; Thomas, S. B.; Travnicek, P.
The Fluorescence detector Array of Single-pixel Telescopes (FAST) is a design concept for the next generation of ultrahigh-energy cosmic ray (UHECR) observatories, addressing the requirements for a large-area, low-cost detector suitable for measuring the properties of the highest energy cosmic rays. In the FAST design, a large field of view is covered by a few pixels at the focal plane of a mirror or Fresnel lens. Motivated by the successful detection of UHECRs using a prototype comprised of a single 200 mm photomultiplier-tube and a 1 m2 Fresnel lens system, we have developed a new "full-scale" prototype consisting of four 200 mm photomultiplier-tubes at the focus of a segmented mirror of 1.6 m in diameter. We report on the status of the full-scale prototype, including test measurements made during first light operation at the Telescope Array site in central Utah, U.S.A.
Large format array controller (aLFA-C): tests and characterisation at ESA
NASA Astrophysics Data System (ADS)
Lemmel, Frédéric; ter Haar, Jörg; van der Biezen, John; Duvet, Ludovic; Nelms, Nick; Blommaert, Sander; Butler, Bart; van der Luijt, Cornelis; Heijnen, Jerko; Smit, Hans; Visser, Ivo
2016-08-01
For future near infrared astronomy missions, ESA is developing a complete detection and conversion chain (photon to SpaceWire chain system): Large Format Array (aLFA-N) based on MCT type detectors. aLFA-C (Astronomy Large Format Array Controller): a versatile cryogenic detector controller. An aLFA-C prototype was developed by Caeleste (Belgium) under ESA contract (400106260400). To validate independently the performances of the aLFA-C prototype and consolidate the definition of the follow-on activity, a dedicated test bench has been designed and developed in ESTEC/ESA within the Payload Technology Validation group. This paper presents the test setup and the performance validation of the first prototype of this controller at room and cryogenic temperature. Test setup and software needed to test the HAWAII-2RG and aLFA-N detectors with the aLFA-C prototype at cryogenic temperature will be also presented.
A second generation 50 Mbps VLSI level zero processing system prototype
NASA Technical Reports Server (NTRS)
Harris, Jonathan C.; Shi, Jeff; Speciale, Nick; Bennett, Toby
1994-01-01
Level Zero Processing (LZP) generally refers to telemetry data processing functions performed at ground facilities to remove all communication artifacts from instrument data. These functions typically include frame synchronization, error detection and correction, packet reassembly and sorting, playback reversal, merging, time-ordering, overlap deletion, and production of annotated data sets. The Data Systems Technologies Division (DSTD) at Goddard Space Flight Center (GSFC) has been developing high-performance Very Large Scale Integration Level Zero Processing Systems (VLSI LZPS) since 1989. The first VLSI LZPS prototype demonstrated 20 Megabits per second (Mbp's) capability in 1992. With a new generation of high-density Application-specific Integrated Circuits (ASIC) and a Mass Storage System (MSS) based on the High-performance Parallel Peripheral Interface (HiPPI), a second prototype has been built that achieves full 50 Mbp's performance. This paper describes the second generation LZPS prototype based upon VLSI technologies.
Enzyme immunoassay for the detection of porcine gelatine in edible bird's nests.
Tukiran, Nur Azira; Ismail, Amin; Mustafa, Shuhaimi; Hamid, Muhajir
2015-01-01
Porcine gelatine is a common adulterant found in edible bird's nests (EBNs) used to increase the net weight prior to sale. This study aimed to develop indirect enzyme-linked immunosorbent assays (ELISAs) for porcine gelatine adulteration using anti-peptide polyclonal antibodies. Three indirect ELISAs were developed (PAB1, 2 and 3), which had limits of detection (LODs) of 0.12, 0.10 and 0.11 µg g(-1), respectively. When applied to standard solutions of porcine gelatine, the inter- and intra-assays showed coefficients of variation (CVs) less than 20% and were able to detect at least 0.5 ng µg(-1) (0.05%) porcine gelatine in spiked samples. The proposed ELISA offers attractions for quality control in the EBN industry.
Hattori, Toshiaki; Anraku, Nobuhiro; Kato, Ryo
2010-02-01
Five chitosan oligosaccharides were separated in acidic aqueous solution by capillary electrophoresis (CE) with indirect photometric detection using a positively coated capillary. Electrophoretic mobility of the chitooligosaccharides (COSs) depended on the number of monomer units in acidic aqueous solution, similar to other polyelectrolyte oligomers. The separation was developed in nitric acid aqueous solution at pH 3.0 with 1 mM Crystal Violet, using a capillary positively coated with N-trimethoxypropyl-N,N,N-trimethylammonium chloride. The limit of the detection for chitooligosaccharides with two to six saccharide chains was less than 5 microM. CE determination of an enzymatically hydrolyzed COS agreed with results from HPLC. 2009 Elsevier B.V. All rights reserved.
Thermodynamic Alerter for Microbursts (TAMP)
NASA Technical Reports Server (NTRS)
Eccles, Peter J.
1991-01-01
The following subject areas are covered: microburst detection, location and measurement; thermal alerter for microbursts prototypes (TAMP); sensor-transmitters (Senstrans) design; TAMP installation; and DAPAD software.
Biosensor UUV payload for underwater detection
NASA Astrophysics Data System (ADS)
Kusterbeck, Anne W.; Charles, Paul T.; Melde, Brian J.; Trammell, Scott A.; Adams, André A.; Deschamps, Jeffrey R.
2010-04-01
Increased emphasis on maritime domain awareness and port security has led to the development of unmanned underwater vehicles (UUVs) capable of extended missions. These systems rely most frequently on well-developed side scan sonar and acoustic methods to locate potential targets. The Naval Research Laboratory (NRL) is developing biosensors for underwater explosives detection that complement acoustic sensors and can be used as UUV payloads to monitor areas for port and harbor security or in detection of underwater unexploded ordnance (UXO) and biochemical threats. The prototype sensor has recently been demonstrated to detect explosives in seawater at trace levels when run in a continuous sampling mode. To overcome ongoing issues with sample preparation and facilitate rapid detection at trace levels in a marine environment, we have been developing new mesoporous materials for in-line preconcentration of explosives and other small molecules, engineering microfluidic components to improve the signal, and testing alternative signal transduction methods. Additional work is being done to optimize the optical components and sensor response time. Highlights of these current studies and our ongoing efforts to integrate the biosensor with existing detection technologies to reduce false positives are described. In addition, we present the results of field tests that demonstrate the prototype biosensor performance as a UUV payload.
Gornowicz-Porowska, Justyna; Seraszek-Jaros, Agnieszka; Bowszyc-Dmochowska, Monika; Kaczmarek, Elżbieta; Pietkiewicz, Paweł; Bartkiewicz, Paweł; Dmochowski, Marian
2017-02-01
Pemphigus and bullous pemphigoid (BP) are identified by autoantibodies (abs) against desmoglein 1, 3 (DSG1/3) and BP180/BP230, respectively. A novel mosaic to indirect immunofluorescence (IIF) using purified BP180 recombinant proteins spotted on slide and transfected cells expressing BP230, DSG1, DSG3 is available. The commercial (IgG detection) and modified (IgG4 detection) mosaic for indirect immunofluorescence (IIFc - IIF commercial, IIFm - IIF modified) and IgG ELISAs were evaluated in pemphigus and bullous pemphigoid (BP) molecular diagnostics. To compare diagnostic accuracy of commercial (IgG detection) and modified (IgG4 detection) mosaic IIF assay and to examine the diagnostic value of ELISAs in relation to mosaic IIF in routine laboratory diagnostics of pemphigus and BP. Sera from 37 BP and 19 pemphigus patients were studied. Associations between tests were assessed using Fisher's exact test. There are associations between the positive/negative samples detected by IIFc with desmoglein1 (DSG1)/desmoglein3 (DSG3)/BP230 transfected cells and ELISAs and no association between anti-BP180 IgG detection by IIFc and ELISA. IIFm with DSG1 and DSG3 showed both 100% sensitivity and 100% and 78% specificity, respectively, and 100% and 83% positive predictive value in relation to IIFc. IIFm with BP230 had 87% specificity, 55% sensitivity, whereas IIFm with BP180 had a 100% sensitivity and 13% specificity in relation to IIFc. The IIFc with DSG1/DSG3/BP230 transfected cells, excluding BP180 spots, is an alternative method to ELISA in pemphigus/BP diagnostics. IgG4 antibodies, both pathogenically and diagnostically important, are inconsistently detectable with IIFm.
A study of CR-39 plastic charged-particle detector replacement by consumer imaging sensors
NASA Astrophysics Data System (ADS)
Plaud-Ramos, K. O.; Freeman, M. S.; Wei, W.; Guardincerri, E.; Bacon, J. D.; Cowan, J.; Durham, J. M.; Huang, D.; Gao, J.; Hoffbauer, M. A.; Morley, D. J.; Morris, C. L.; Poulson, D. C.; Wang, Zhehui
2016-11-01
Consumer imaging sensors (CIS) are examined for real-time charged-particle detection and CR-39 plastic detector replacement. Removing cover glass from CIS is hard if not impossible, in particular for the latest inexpensive webcam models. We show that 10-class CIS are sensitive to MeV and higher energy protons and α-particles by using a 90Sr β-source with its cover glass in place. Indirect, real-time, high-resolution detection is also feasible when combining CIS with a ZnS:Ag phosphor screen and optics. Noise reduction in CIS is nevertheless important for the indirect approach.
A study of CR-39 plastic charged-particle detector replacement by consumer imaging sensors
Plaud-Ramos, Kenie Omar; Freeman, Matthew Stouten; Wei, Wanchun; ...
2016-08-03
Consumer imaging sensors (CIS) are examined for real-time charged-particle detection and CR-39 plastic detector replacement. Removing cover glass from CIS is hard if not impossible, in particular for the latest inexpensive webcam models. We show that $10-class CIS are sensitive to MeV and higher energy protons and α-particles by using a 90Sr β-source with its cover glass in place. Indirect, real-time, high-resolution detection is also feasible when combining CIS with a ZnS:Ag phosphor screen and optics. Furthermore, noise reduction in CIS is nevertheless important for the indirect approach.
A study of CR-39 plastic charged-particle detector replacement by consumer imaging sensors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plaud-Ramos, K. O.; Freeman, M. S.; Wei, W.
Consumer imaging sensors (CIS) are examined for real-time charged-particle detection and CR-39 plastic detector replacement. Removing cover glass from CIS is hard if not impossible, in particular for the latest inexpensive webcam models. We show that $10-class CIS are sensitive to MeV and higher energy protons and α-particles by using a {sup 90}Sr β-source with its cover glass in place. Indirect, real-time, high-resolution detection is also feasible when combining CIS with a ZnS:Ag phosphor screen and optics. Noise reduction in CIS is nevertheless important for the indirect approach.
A study of CR-39 plastic charged-particle detector replacement by consumer imaging sensors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plaud-Ramos, Kenie Omar; Freeman, Matthew Stouten; Wei, Wanchun
Consumer imaging sensors (CIS) are examined for real-time charged-particle detection and CR-39 plastic detector replacement. Removing cover glass from CIS is hard if not impossible, in particular for the latest inexpensive webcam models. We show that $10-class CIS are sensitive to MeV and higher energy protons and α-particles by using a 90Sr β-source with its cover glass in place. Indirect, real-time, high-resolution detection is also feasible when combining CIS with a ZnS:Ag phosphor screen and optics. Furthermore, noise reduction in CIS is nevertheless important for the indirect approach.
The biocompatibility of modified experimental Portland cements with potential for use in dentistry.
Camilleri, J
2008-12-01
To evaluate the biocompatibility of a group of new potential dental materials and their eluants by assessing cell viability. Calcium sulpho-aluminate cement (CSA), calcium fluoro-aluminate cement (CFA) and glass-ionomer cement (GIC; Ketac Molar), used as the control, were tested for biocompatibility. Using a direct test method cell viability was measured quantitatively using alamarBluetrade mark dye, and an indirect test method where cells were grown on material elutions and cell viability was assessed using methyltetrazolium (MTT) assay as recommended by ISO 10 993-Part 5 for in vitro testing. Statistical analysis was performed by analysis of variance and Tukey multi-comparison test method. Elution collected from the prototype cements and the GIC cured for 1 and 7 days allowed high cell activity after 24 h cell exposure, which reduced after 48 h when compared to the nontoxic glass-ionomer control, but increased significantly after 72 h cell contact. Elutions collected after 28 days revealed reduced cell activity at all cell exposure times. Cells placed in direct contact with the prototype materials showed reduced cell activity when compared with the control. Cell growth was poor when seeded in direct contact with the prototype cements. GIC encouraged cell growth after 1 day of contact. The eluted species for all the cements tested exhibited adequate cell viability in the early ages with reduced cell activity at 28 days. Changes in the production of calcium hydroxide as a by-product of cement hydration affect the material biocompatibility adversely.
Cosmic Ray Inspection and Passive Tomography for SNM Detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Armitage, John; Oakham, Gerald; Bryman, Douglas
2009-12-02
The Cosmic Ray Inspection and Passive Tomography (CRIPT) project has recently started investigating the detection of illicit Special Nuclear Material in cargo using cosmic ray muon tomography and complementary neutron detectors. We are currently performing simulation studies to help with the design of small scale prototypes. Based on the prototype tests and refined simulations, we will determine whether the muon tracking system for the full scale prototype will be based on drift chambers or extruded scintillator trackers. An analysis of the operations of the Port of Montreal has determined how long muon scan times should take if all or amore » subset of the cargo is to be screened. As long as the throughput of the muon system(s) is equal to the rate at which containers are unloaded from ships, the impact on port operations would not be great if a muon scanning stage were required for all cargo. We also show preliminary simulation results indicating that excellent separation between Al, Fe and Pb is possible under ideal conditions. The discrimination power is reduced but still significant when realistic momentum resolution measurements are considered.« less
Cosmic Ray Inspection and Passive Tomography for SNM Detection
NASA Astrophysics Data System (ADS)
Armitage, John; Bryman, Douglas; Cousins, Thomas; Gallant, Grant; Jason, Andrew; Jonkmans, Guy; Noël, Scott; Oakham, Gerald; Stocki, Trevor J.; Waller, David
2009-12-01
The Cosmic Ray Inspection and Passive Tomography (CRIPT) project has recently started investigating the detection of illicit Special Nuclear Material in cargo using cosmic ray muon tomography and complementary neutron detectors. We are currently performing simulation studies to help with the design of small scale prototypes. Based on the prototype tests and refined simulations, we will determine whether the muon tracking system for the full scale prototype will be based on drift chambers or extruded scintillator trackers. An analysis of the operations of the Port of Montreal has determined how long muon scan times should take if all or a subset of the cargo is to be screened. As long as the throughput of the muon system(s) is equal to the rate at which containers are unloaded from ships, the impact on port operations would not be great if a muon scanning stage were required for all cargo. We also show preliminary simulation results indicating that excellent separation between Al, Fe and Pb is possible under ideal conditions. The discrimination power is reduced but still significant when realistic momentum resolution measurements are considered.
Integration and test of high-speed transmitter electronics for free-space laser communications
NASA Technical Reports Server (NTRS)
Soni, Nitin J.; Lizanich, Paul J.
1994-01-01
The NASA Lewis Research Center in Cleveland, Ohio, has developed the electronics for a free-space, direct-detection laser communications system demonstration. Under the High-Speed Laser Integrated Terminal Electronics (Hi-LITE) Project, NASA Lewis has built a prototype full-duplex, dual-channel electronics transmitter and receiver operating at 325 megabit S per second (Mbps) per channel and using quaternary pulse-position modulation (QPPM). This paper describes the integration and testing of the transmitter portion for future application in free-space, direct-detection laser communications. A companion paper reviews the receiver portion of the prototype electronics. Minor modifications to the transmitter were made since the initial report on the entire system, and this paper addresses them. The digital electronics are implemented in gallium arsenide integrated circuits mounted on prototype boards. The fabrication and implementation issues related to these high-speed devices are discussed. The transmitter's test results are documented, and its functionality is verified by exercising all modes of operation. Various testing issues pertaining to high-speed circuits are addressed. A description of the transmitter electronics packaging concludes the paper.
Sensors on instrumented socks for detection of lower leg edema--An in vitro study.
Zhang, Song; Rajamani, Rajesh
2015-01-01
This paper presents the design, sensing principles and in vitro evaluation of a novel instrumented sock intended for prediction and prevention of acute decompensated heart failure. The sock contains a drift-free ankle size sensor and a leg tissue elasticity sensor. Both sensors are inexpensive and developed using innovative new sensing ideas. Preliminary tests with the sensor prototypes show promising results: The ankle size sensor is capable of measuring 1 mm changes in ankle diameter and the tissue elasticity sensor can detect 0.15 MPa differences in elasticity. A low-profile instrumented sock prototype with these two sensors has been successfully fabricated and will be evaluated in the future in an IRB-approved human study.
Large area MEMS based ultrasound device for cancer detection
NASA Astrophysics Data System (ADS)
Wodnicki, Robert; Thomenius, Kai; Ming Hooi, Fong; Sinha, Sumedha P.; Carson, Paul L.; Lin, Der-Song; Zhuang, Xuefeng; Khuri-Yakub, Pierre; Woychik, Charles
2011-08-01
We present image results obtained using a prototype ultrasound array that demonstrates the fundamental architecture for a large area MEMS based ultrasound device for detection of breast cancer. The prototype array consists of a tiling of capacitive Micromachined Ultrasound Transducers (cMUTs) that have been flip-chip attached to a rigid organic substrate. The pitch on the cMUT elements is 185 μm and the operating frequency is nominally 9 MHz. The spatial resolution of the new probe is comparable to those of production PZT probes; however the sensitivity is reduced by conditions that should be correctable. Simulated opposed-view image registration and Speed of Sound volume reconstruction results for ultrasound in the mammographic geometry are also presented.
Park, Steve; Guan, Xiying; Kim, Youngwan; Creighton, Francis Pete X; Wei, Eric; Kymissis, Ioannis John; Nakajima, Hideko Heidi; Olson, Elizabeth S
2018-01-01
We report the fabrication and characterization of a prototype polyvinylidene fluoride polymer-based implantable microphone for detecting sound inside gerbil and human cochleae. With the current configuration and amplification, the signal-to-noise ratios were sufficiently high for normally occurring sound pressures and frequencies (ear canal pressures >50-60 dB SPL and 0.1-10 kHz), though 10 to 20 dB poorer than for some hearing aid microphones. These results demonstrate the feasibility of the prototype devices as implantable microphones for the development of totally implantable cochlear implants. For patients, this will improve sound reception by utilizing the outer ear and will improve the use of cochlear implants.
Guan, Xiying; Kim, Youngwan; Creighton, Francis (Pete) X.; Wei, Eric; Kymissis, Ioannis(John); Nakajima, Hideko Heidi; Olson, Elizabeth S.
2018-01-01
We report the fabrication and characterization of a prototype polyvinylidene fluoride polymer-based implantable microphone for detecting sound inside gerbil and human cochleae. With the current configuration and amplification, the signal-to-noise ratios were sufficiently high for normally occurring sound pressures and frequencies (ear canal pressures >50–60 dB SPL and 0.1–10 kHz), though 10 to 20 dB poorer than for some hearing aid microphones. These results demonstrate the feasibility of the prototype devices as implantable microphones for the development of totally implantable cochlear implants. For patients, this will improve sound reception by utilizing the outer ear and will improve the use of cochlear implants. PMID:29732950
Prototype high resolution multienergy soft x-ray array for NSTX.
Tritz, K; Stutman, D; Delgado-Aparicio, L; Finkenthal, M; Kaita, R; Roquemore, L
2010-10-01
A novel diagnostic design seeks to enhance the capability of multienergy soft x-ray (SXR) detection by using an image intensifier to amplify the signals from a larger set of filtered x-ray profiles. The increased number of profiles and simplified detection system provides a compact diagnostic device for measuring T(e) in addition to contributions from density and impurities. A single-energy prototype system has been implemented on NSTX, comprised of a filtered x-ray pinhole camera, which converts the x-rays to visible light using a CsI:Tl phosphor. SXR profiles have been measured in high performance plasmas at frame rates of up to 10 kHz, and comparisons to the toroidally displaced tangential multi-energy SXR have been made.
Bhavani, Selvaraj Rani; Senthilkumar, Jagatheesan; Chilambuchelvan, Arul Gnanaprakasam; Manjula, Dhanabalachandran; Krishnamoorthy, Ramasamy; Kannan, Arputharaj
2015-03-27
The Internet has greatly enhanced health care, helping patients stay up-to-date on medical issues and general knowledge. Many cancer patients use the Internet for cancer diagnosis and related information. Recently, cloud computing has emerged as a new way of delivering health services but currently, there is no generic and fully automated cloud-based self-management intervention for breast cancer patients, as practical guidelines are lacking. We investigated the prevalence and predictors of cloud use for medical diagnosis among women with breast cancer to gain insight into meaningful usage parameters to evaluate the use of generic, fully automated cloud-based self-intervention, by assessing how breast cancer survivors use a generic self-management model. The goal of this study was implemented and evaluated with a new prototype called "CIMIDx", based on representative association rules that support the diagnosis of medical images (mammograms). The proposed Cloud-Based System Support Intelligent Medical Image Diagnosis (CIMIDx) prototype includes two modules. The first is the design and development of the CIMIDx training and test cloud services. Deployed in the cloud, the prototype can be used for diagnosis and screening mammography by assessing the cancers detected, tumor sizes, histology, and stage of classification accuracy. To analyze the prototype's classification accuracy, we conducted an experiment with data provided by clients. Second, by monitoring cloud server requests, the CIMIDx usage statistics were recorded for the cloud-based self-intervention groups. We conducted an evaluation of the CIMIDx cloud service usage, in which browsing functionalities were evaluated from the end-user's perspective. We performed several experiments to validate the CIMIDx prototype for breast health issues. The first set of experiments evaluated the diagnostic performance of the CIMIDx framework. We collected medical information from 150 breast cancer survivors from hospitals and health centers. The CIMIDx prototype achieved high sensitivity of up to 99.29%, and accuracy of up to 98%. The second set of experiments evaluated CIMIDx use for breast health issues, using t tests and Pearson chi-square tests to assess differences, and binary logistic regression to estimate the odds ratio (OR) for the predictors' use of CIMIDx. For the prototype usage statistics for the same 150 breast cancer survivors, we interviewed 114 (76.0%), through self-report questionnaires from CIMIDx blogs. The frequency of log-ins/person ranged from 0 to 30, total duration/person from 0 to 1500 minutes (25 hours). The 114 participants continued logging in to all phases, resulting in an intervention adherence rate of 44.3% (95% CI 33.2-55.9). The overall performance of the prototype for the good category, reported usefulness of the prototype (P=.77), overall satisfaction of the prototype (P=.31), ease of navigation (P=.89), user friendliness evaluation (P=.31), and overall satisfaction (P=.31). Positive evaluations given by 100 participants via a Web-based questionnaire supported our hypothesis. The present study shows that women felt favorably about the use of a generic fully automated cloud-based self- management prototype. The study also demonstrated that the CIMIDx prototype resulted in the detection of more cancers in screening and diagnosing patients, with an increased accuracy rate.
CCD Detects Two Images In Quick Succession
NASA Technical Reports Server (NTRS)
Janesick, James R.; Collins, Andy
1996-01-01
Prototype special-purpose charge-coupled device (CCD) designed to detect two 1,024 x 1,024-pixel images in rapid succession. Readout performed slowly to minimize noise. CCD operated in synchronism with pulsed laser, stroboscope, or other pulsed source of light to form pairs of images of rapidly moving objects.
Expert System Detects Power-Distribution Faults
NASA Technical Reports Server (NTRS)
Walters, Jerry L.; Quinn, Todd M.
1994-01-01
Autonomous Power Expert (APEX) computer program is prototype expert-system program detecting faults in electrical-power-distribution system. Assists human operators in diagnosing faults and deciding what adjustments or repairs needed for immediate recovery from faults or for maintenance to correct initially nonthreatening conditions that could develop into faults. Written in Lisp.
A SIMPLE HPLC METHOD FOR DETECTING CARBARYL AND 1-NAPHTHOL IN BIOLOGICAL TISSUES.
Carbamates are a class of pesticide used in both agricultural and residential applications. A simple HPLC method for detecting Carb and its metabolite 1-naphthol (Naph) in tissues was developed to try to correlate tissue levels of carbaryl (Carb) (a prototypical carbamate) with c...
Erythropoietin abuse and erythropoietin gene doping: detection strategies in the genomic era.
Diamanti-Kandarakis, Evanthia; Konstantinopoulos, Panagiotis A; Papailiou, Joanna; Kandarakis, Stylianos A; Andreopoulos, Anastasios; Sykiotis, Gerasimos P
2005-01-01
The administration of recombinant human erythropoietin (rhEPO) increases the maximum oxygen consumption capacity, and is therefore abused as a doping method in endurance sports. The detection of erythropoietin (EPO) abuse is based on direct pharmacological and indirect haematological approaches, both of which have several limitations. In addition, current detection methods cannot cope with the emerging doping strategies of EPO mimicry, analogues and gene doping, and thus novel detection strategies are urgently needed. Direct detection methods for EPO misuse can be either pharmacological approaches that identify exogenous substances based on their physicochemical properties, or molecular methods that recognise EPO transgenes or gene transfer vectors. Since direct detection with molecular methods requires invasive procedures, it is not appropriate for routine screening of large numbers of athletes. In contrast, novel indirect methods based on haematological and/or molecular profiling could be better suited as screening tools, and athletes who are suspect of doping would then be submitted to direct pharmacological and molecular tests. This article reviews the current state of the EPO doping field, discusses available detection methods and their shortcomings, outlines emerging pharmaceutical and genetic technologies in EPO misuse, and proposes potential directions for the development of novel detection strategies.
Roadside Tracker Portal-less Portal Monitor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ziock, Klaus-Peter; Cheriyadat, Anil M.; Bradley, Eric Craig
2013-07-01
This report documents the full development cycle of the Roadside Tracker (RST) Portal-less Portal monitor (Fig. 1) funded by DHS DNDO. The project started with development of a proof-of-feasibility proto-type, proceeded through design and construction of a proof-of-concept (POC) prototype, a test-and-evaluation phase, participation in a Limited Use Exercise that included the Standoff Radiation Detections Systems developed under an Advanced Technology Demonstration and concluded with participation in a Characterization Study conducted by DNDO.
Performance of a full scale prototype detector at the BR2 reactor for the SoLid experiment
NASA Astrophysics Data System (ADS)
Abreu, Y.; Amhis, Y.; Arnold, L.; Ban, G.; Beaumont, W.; Bongrand, M.; Boursette, D.; Castle, B. C.; Clark, K.; Coupé, B.; Cussans, D.; De Roeck, A.; D'Hondt, J.; Durand, D.; Fallot, M.; Ghys, L.; Giot, L.; Guillon, B.; Ihantola, S.; Janssen, X.; Kalcheva, S.; Kalousis, L. N.; Koonen, E.; Labare, M.; Lehaut, G.; Manzanillas, L.; Mermans, J.; Michiels, I.; Moortgat, C.; Newbold, D.; Park, J.; Pestel, V.; Petridis, K.; Piñera, I.; Pommery, G.; Popescu, L.; Pronost, G.; Rademacker, J.; Ryckbosch, D.; Ryder, N.; Saunders, D.; Schune, M.-H.; Simard, L.; Vacheret, A.; Van Dyck, S.; Van Mulders, P.; van Remortel, N.; Vercaemer, S.; Verstraeten, M.; Weber, A.; Yermia, F.
2018-05-01
The SoLid collaboration has developed a new detector technology to detect electron anti-neutrinos at close proximity to the Belgian BR2 reactor at surface level. A 288 kg prototype detector was deployed in 2015 and collected data during the operational period of the reactor and during reactor shut-down. Dedicated calibration campaigns were also performed with gamma and neutron sources. This paper describes the construction of the prototype detector with a high control on its proton content and the stability of its operation over a period of several months after deployment at the BR2 reactor site. All detector cells provide sufficient light yields to achieve a target energy resolution of better than 20%/√E(MeV). The capability of the detector to track muons is exploited to equalize the light response of a large number of channels to a precision of 3% and to demonstrate the stability of the energy scale over time. Particle identification based on pulse-shape discrimination is demonstrated with calibration sources. Despite a lower neutron detection efficiency due to triggering constraints, the main backgrounds at the reactor site were determined and taken into account in the shielding strategy for the main experiment. The results obtained with this prototype proved essential in the design optimization of the final detector.
New consumer load prototype for electricity theft monitoring
NASA Astrophysics Data System (ADS)
Abdullateef, A. I.; Salami, M. J. E.; Musse, M. A.; Onasanya, M. A.; Alebiosu, M. I.
2013-12-01
Illegal connection which is direct connection to the distribution feeder and tampering of energy meter has been identified as a major process through which nefarious consumers steal electricity on low voltage distribution system. This has contributed enormously to the revenue losses incurred by the power and energy providers. A Consumer Load Prototype (CLP) is constructed and proposed in this study in order to understand the best possible pattern through which the stealing process is effected in real life power consumption. The construction of consumer load prototype will facilitate real time simulation and data collection for the monitoring and detection of electricity theft on low voltage distribution system. The prototype involves electrical design and construction of consumer loads with application of various standard regulations from Institution of Engineering and Technology (IET), formerly known as Institution of Electrical Engineers (IEE). LABVIEW platform was used for data acquisition and the data shows a good representation of the connected loads. The prototype will assist researchers and power utilities, currently facing challenges in getting real time data for the study and monitoring of electricity theft. The simulation of electricity theft in real time is one of the contributions of this prototype. Similarly, the power and energy community including students will appreciate the practical approach which the prototype provides for real time information rather than software simulation which has hitherto been used in the study of electricity theft.
Tankaew, Pallop; Singh-La, Thawatchai; Titaram, Chatchote; Punyapornwittaya, Veerasak; Vongchan, Preeyanat; Sawada, Takuo; Sthitmatee, Nattawooti
2017-03-01
Pasteurella multocida causes haemorrhagic septicemia in livestock and wild animals, including elephants. The disease has been reported in Asian elephants in India and Sri Lanka, but to date there have been no reported cases in Thailand. ELISA or indirect hemagglutination assays (IHA) have been demonstrated to be able to detect the antibody against the disease in cattle, but no data are available for elephants. The present study reports a novel in-house indirect ELISA for antibody detection of haemorrhagic septicemia in Asian elephants, and evaluates the sensitivity and specificity of the method using a Bayesian approach. The characteristics of ELISA and IHA were analyzed using a one population Bayesian model assuming conditional dependence between these two diagnostic tests. The IHA was performed as recommended by the World Organization for Animal Health (OIE) manual for haemorrhagic septicemia. An in-house indirect ELISA was developed with a heat extract antigen of P. multocida strain M-1404 (serovar B:2) as a coating antigen and rabbit anti-immunoglobulin G conjugated with horseradish peroxidase (eIgG-HRP). The checkerboard titration method was done using elephant sera immunized with P. multocida bacterin and negative sera from colostrum-deprived elephant calves. The concentrations of heat extract antigen (160μg/ml), sample serum (1:100), and eIgG-HRP (1:1000) were optimal for the assay. The calculated cut-off value was 0.103. Of the elephant sera, 50.59% (43/85) were considered seropositive by ELISA. The sensitivity of the ELISA test was higher than that of the IHA test [median=86.5%, 95% posterior probability interval (PPI)=52.5-98.9%] while the specificity was lower (median=54.1%, PPI=43.6-64.7%). The median sensitivity and specificity of IHA were 80.5% (PPI=43.8-98.0%) and 78.4% (PPI=69.0-87.0%), respectively. These findings suggest that our in-house indirect ELISA can be used as a tool to detect the antibody against haemorrhagic septicemia in Asian elephants. Copyright © 2017 Elsevier B.V. All rights reserved.
Smith, M.; Murphy, D.; Laxmisan, A.; Sittig, D.; Reis, B.; Esquivel, A.; Singh, H.
2013-01-01
Summary Background Abnormal test results do not always receive timely follow-up, even when providers are notified through electronic health record (EHR)-based alerts. High workload, alert fatigue, and other demands on attention disrupt a provider’s prospective memory for tasks required to initiate follow-up. Thus, EHR-based tracking and reminding functionalities are needed to improve follow-up. Objectives The purpose of this study was to develop a decision-support software prototype enabling individual and system-wide tracking of abnormal test result alerts lacking follow-up, and to conduct formative evaluations, including usability testing. Methods We developed a working prototype software system, the Alert Watch And Response Engine (AWARE), to detect abnormal test result alerts lacking documented follow-up, and to present context-specific reminders to providers. Development and testing took place within the VA’s EHR and focused on four cancer-related abnormal test results. Design concepts emphasized mitigating the effects of high workload and alert fatigue while being minimally intrusive. We conducted a multifaceted formative evaluation of the software, addressing fit within the larger socio-technical system. Evaluations included usability testing with the prototype and interview questions about organizational and workflow factors. Participants included 23 physicians, 9 clinical information technology specialists, and 8 quality/safety managers. Results Evaluation results indicated that our software prototype fit within the technical environment and clinical workflow, and physicians were able to use it successfully. Quality/safety managers reported that the tool would be useful in future quality assurance activities to detect patients who lack documented follow-up. Additionally, we successfully installed the software on the local facility’s “test” EHR system, thus demonstrating technical compatibility. Conclusion To address the factors involved in missed test results, we developed a software prototype to account for technical, usability, organizational, and workflow needs. Our evaluation has shown the feasibility of the prototype as a means of facilitating better follow-up for cancer-related abnormal test results. PMID:24155789
Smith, M; Murphy, D; Laxmisan, A; Sittig, D; Reis, B; Esquivel, A; Singh, H
2013-01-01
Abnormal test results do not always receive timely follow-up, even when providers are notified through electronic health record (EHR)-based alerts. High workload, alert fatigue, and other demands on attention disrupt a provider's prospective memory for tasks required to initiate follow-up. Thus, EHR-based tracking and reminding functionalities are needed to improve follow-up. The purpose of this study was to develop a decision-support software prototype enabling individual and system-wide tracking of abnormal test result alerts lacking follow-up, and to conduct formative evaluations, including usability testing. We developed a working prototype software system, the Alert Watch And Response Engine (AWARE), to detect abnormal test result alerts lacking documented follow-up, and to present context-specific reminders to providers. Development and testing took place within the VA's EHR and focused on four cancer-related abnormal test results. Design concepts emphasized mitigating the effects of high workload and alert fatigue while being minimally intrusive. We conducted a multifaceted formative evaluation of the software, addressing fit within the larger socio-technical system. Evaluations included usability testing with the prototype and interview questions about organizational and workflow factors. Participants included 23 physicians, 9 clinical information technology specialists, and 8 quality/safety managers. Evaluation results indicated that our software prototype fit within the technical environment and clinical workflow, and physicians were able to use it successfully. Quality/safety managers reported that the tool would be useful in future quality assurance activities to detect patients who lack documented follow-up. Additionally, we successfully installed the software on the local facility's "test" EHR system, thus demonstrating technical compatibility. To address the factors involved in missed test results, we developed a software prototype to account for technical, usability, organizational, and workflow needs. Our evaluation has shown the feasibility of the prototype as a means of facilitating better follow-up for cancer-related abnormal test results.
Chavaillaz, Alain; Schwaninger, Adrian; Michel, Stefan; Sauer, Juergen
2018-05-25
The present study evaluated three automation modes for improving performance in an X-ray luggage screening task. 140 participants were asked to detect the presence of prohibited items in X-ray images of cabin luggage. Twenty participants conducted this task without automatic support (control group), whereas the others worked with either indirect cues (system indicated the target presence without specifying its location), or direct cues (system pointed out the exact target location) or adaptable automation (participants could freely choose between no cue, direct and indirect cues). Furthermore, automatic support reliability was manipulated (low vs. high). The results showed a clear advantage for direct cues regarding detection performance and response time. No benefits were observed for adaptable automation. Finally, high automation reliability led to better performance and higher operator trust. The findings overall confirmed that automatic support systems for luggage screening should be designed such that they provide direct, highly reliable cues.
Evaluation of indirect impedance for measuring microbial growth in complex food matrices.
Johnson, N; Chang, Z; Bravo Almeida, C; Michel, M; Iversen, C; Callanan, M
2014-09-01
The suitability of indirect impedance to accurately measure microbial growth in real food matrices was investigated. A variety of semi-solid and liquid food products were inoculated with Bacillus cereus, Listeria monocytogenes, Staphylococcus aureus, Lactobacillus plantarum, Pseudomonas aeruginosa, Escherichia coli, Salmonella enteriditis, Candida tropicalis or Zygosaccharomyces rouxii and CO2 production was monitored using a conductimetric (Don Whitely R.A.B.I.T.) system. The majority (80%) of food and microbe combinations produced a detectable growth signal. The linearity of conductance responses in selected food products was investigated and a good correlation (R(2) ≥ 0.84) was observed between inoculum levels and times to detection. Specific growth rate estimations from the data were sufficiently accurate for predictive modeling in some cases. This initial evaluation of the suitability of indirect impedance to generate microbial growth data in complex food matrices indicates significant potential for the technology as an alternative to plating methods. Copyright © 2014 Elsevier Ltd. All rights reserved.
Comparison of a direct and indirect ELISA for quantitating antisperm antibody in semen.
Lynch, D M; Howe, S E
1987-01-01
A direct and an indirect quantitative ELISA for antisperm antibody were compared using the spermatozoa and cell-free seminal fluid of 66 infertile males. The normal concentration of sperm binding immunoglobulin was less than or equal to 1.5 fg Ig per spermatozoon for the indirect seminal plasma assay and less than or equal to 1.5 fg Ig per spermatozoon by the direct assay. Of the 66 infertile males, 21% (14/66) had elevated levels of antisperm antibody in their seminal plasma and 26% (17/66) had elevated levels bound directly to their spermatozoa. The direct correlation between the results of these assays was 94%. A simple linear regression analysis between the indirect and direct measurements of antisperm antibody resulted in a correlation coefficient of r = 0.907. There was no statistically significant difference between results from the direct and indirect methods of the patients as a group. However, there was evidence of autospecificity in a small percentage of males who had elevated levels of antisperm antibody by the direct assay that was not detected by the indirect assay using pooled donor spermatozoa.
Mode-Specific SN2 Reaction Dynamics.
Wang, Yan; Song, Hongwei; Szabó, István; Czakó, Gábor; Guo, Hua; Yang, Minghui
2016-09-01
Despite its importance in chemistry, the microscopic dynamics of bimolecular nucleophilic substitution (SN2) reactions is still not completely elucidated. In this publication, the dynamics of a prototypical SN2 reaction (F(-) + CH3Cl → CH3F + Cl(-)) is investigated using a high-dimensional quantum mechanical model on an accurate potential energy surface (PES) and further analyzed by quasi-classical trajectories on the same PES. While the indirect mechanism dominates at low collision energies, the direct mechanism makes a significant contribution. The reactivity is found to depend on the specific reactant vibrational mode excitation. The mode specificity, which is more prevalent in the direct reaction, is rationalized by a transition-state-based model.
Exploring a Nearby Habitable World...Orbiting an M-Dwarf Star
NASA Technical Reports Server (NTRS)
Deming, Drake
2010-01-01
Topics include: the landscape of extrasolar planets and detection techniques, direct and indirect detection methods, summary of the known exoplanets, exploiting transits to characterize super earth atmospheres, how to characterize exoplanet atmospheres, and emitted or reflected spectra of hot Jupiters.
Implementation of a microcontroller-based semi-automatic coagulator.
Chan, K; Kirumira, A; Elkateeb, A
2001-01-01
The coagulator is an instrument used in hospitals to detect clot formation as a function of time. Generally, these coagulators are very expensive and therefore not affordable by a doctors' office and small clinics. The objective of this project is to design and implement a low cost semi-automatic coagulator (SAC) prototype. The SAC is capable of assaying up to 12 samples and can perform the following tests: prothrombin time (PT), activated partial thromboplastin time (APTT), and PT/APTT combination. The prototype has been tested successfully.
Heeney, J L; Evermann, J F; McKeirnan, A J; Marker-Kraus, L; Roelke, M E; Bush, M; Wildt, D E; Meltzer, D G; Colly, L; Lukas, J
1990-01-01
The extent and progression of exposure to feline infectious peritonitis (FIP) virus in the cheetah, Acinonyx jubatus, was monitored by a world-wide serological survey with indirect fluorescent antibody titers to coronavirus. The indirect fluorescent antibody assay was validated by Western blots, which showed that all indirect fluorescent antibody-positive cheetah sera detected both domestic cat and cheetah coronavirus structural proteins. There was a poor correlation between indirect fluorescent antibody results and the presence of coronaviruslike particles in cheetah feces, suggesting that electron microscopic detection of shed particles may not be an easily interpreted diagnostic parameter for FIP disease. Low, but verifiable (by Western blots [immunoblots]) antibody titers against coronavirus were detected in eight free-ranging cheetahs from east Africa as well as from captive cheetahs throughout the world. Of 20 North American cheetah facilities screened, 9 had cheetahs with measurable antibodies to feline coronavirus. Five facilities showed patterns of an ongoing epizootic. Retrospective FIP virus titers of an FIP outbreak in a cheetah-breeding facility in Oregon were monitored over a 5-year period and are interpreted here in terms of clinical disease progression. During that outbreak the morbidity was over 90% and the mortality was 60%, far greater than any previously reported epizootic of FIP in any cat species. Age of infection was a significant risk factor in this epizootic, with infants (less than 3 months old) displaying significantly higher risk for mortality than subadults or adults. Based upon these observations, empirical generalizations are drawn which address epidemiologic concerns for cheetahs in the context of this lethal infectious agent. Images PMID:2157864
Cnops, Lieselotte; Van den Eede, Peter; Pettitt, James; Heyndrickx, Leo; De Smet, Birgit; Coppens, Sandra; Andries, Ilse; Pattery, Theresa; Van Hove, Luc; Meersseman, Geert; Van Den Herrewegen, Sari; Vergauwe, Nicolas; Thijs, Rein; Jahrling, Peter B.; Nauwelaers, David; Ariën, Kevin K.
2016-01-01
Background. The 2013–2016 Ebola epidemic in West Africa resulted in accelerated development of rapid diagnostic tests for emergency outbreak preparedness. We describe the development and evaluation of the Idylla™ prototype Ebola virus test, a fully automated sample-to-result molecular diagnostic test for rapid detection of Zaire ebolavirus (EBOV) and Sudan ebolavirus (SUDV). Methods. The Idylla™ prototype Ebola virus test can simultaneously detect EBOV and SUDV in 200 µL of whole blood. The sample is directly added to a disposable cartridge containing all reagents for sample preparation, RNA extraction, and amplification by reverse-transcription polymerase chain reaction analysis. The performance was evaluated with a variety of sample types, including synthetic constructs and whole blood samples from healthy volunteers spiked with viral RNA, inactivated virus, and infectious virus. Results. The 95% limits of detection for EBOV and SUDV were 465 plaque-forming units (PFU)/mL (1010 copies/mL) and 324 PFU/mL (8204 copies/mL), respectively. In silico and in vitro analyses demonstrated 100% correct reactivity for EBOV and SUDV and no cross-reactivity with relevant pathogens. The diagnostic sensitivity was 97.4% (for EBOV) and 91.7% (for SUDV), the specificity was 100%, and the diagnostic accuracy was 95.9%. Conclusions. The Idylla™ prototype Ebola virus test is a fast, safe, easy-to-use, and near-patient test that meets the performance criteria to detect EBOV in patients with suspected Ebola. PMID:27247341
NASA Astrophysics Data System (ADS)
McFee, John E.; Russell, Kevin L.; Chesney, Robert H.; Faust, Anthony A.; Das, Yogadhish
2006-05-01
The Improved Landmine Detection System (ILDS) is intended to meet Canadian military mine clearance requirements in rear area combat situations and peacekeeping on roads and tracks. The system consists of two teleoperated vehicles and a command vehicle. The teleoperated protection vehicle precedes, clearing antipersonnel mines and magnetic and tilt rod-fuzed antitank mines. It consists of an armoured personnel carrier with a forward looking infrared imager, a finger plow or roller and a magnetic signature duplicator. The teleoperated detection vehicle follows to detect antitank mines. The purpose-built vehicle carries forward looking infrared and visible imagers, a 3 m wide, down-looking sensitive electromagnetic induction detector array and a 3 m wide down-looking ground probing radar, which scan the ground in front of the vehicle. Sensor information is combined using navigation sensors and custom navigation, registration, spatial correspondence and data fusion algorithms. Suspicious targets are then confirmed by a thermal neutron activation detector. The prototype, designed and built by Defence R&D Canada, was completed in October 1997. General Dynamics Canada delivered four production units, based on the prototype concept and technologies, to the Canadian Forces (CF) in 2002. ILDS was deployed in Afghanistan in 2003, making the system the first militarily fielded, teleoperated, multi-sensor vehicle-mounted mine detector and the first with a fielded confirmation sensor. Performance of the prototype in Canadian and independent US trials is summarized and recent results from the production version of the confirmation sensor are discussed. CF operations with ILDS in Afghanistan are described.
Surface Magnetic Fields on Giants and Supergiants
NASA Astrophysics Data System (ADS)
Lebre, Agnès
2018-04-01
After a short introduction to spectropolarimetry and the tecnics allowing for the detection of surface fields, I will review the numerous and various detections of magnetic fields at the surface of giant and supergiant stars. On Betelgeuse, the prototype of Red Supergiants, I will present recent results collected after a 10 years long spectropolarimetric survey.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitchell, Dean James; Brusseau, Charles A.
2012-01-01
This document is a final report for the polyvinyl toluene (PVT) neutron-gamma (PVT-NG) project, which was sponsored by the Domestic Nuclear Detection Office (DNDO). The PVT-NG sensor uses PVT detectors for both gamma and neutron detection. The sensor exhibits excellent spectral resolution and gain stabilization, which are features that are beneficial for detection of both gamma-ray and neutron sources. In fact, the ability to perform isotope identification based on spectra that were measured by the PVT-NG sensor was demonstrated. As described in a previous report, the neutron sensitivity of the first version of the prototype was about 25% less thanmore » the DNDO requirement of 2.5 cps/ng for bare Cf-252. This document describes design modifications that were expected to improve the neutron sensitivity by about 50% relative to the PVT-NG prototype. However, the project was terminated before execution of the design modifications after portal vendors demonstrated other technologies that enable neutron detection without the use of He-3. Nevertheless, the PVT-NG sensor development demonstrated several performance goals that may be useful in future portal designs.« less
Jefferies, Ryan; Morgan, Eric R; Helm, Jenny; Robinson, Matthew; Shaw, Susan E
2011-12-01
This study reports the development of a real-time PCR assay and an indirect ELISA to improve on current detection of canine Angiostrongylus vasorum infection. A highly specific fluorescent probe-based, real-time PCR assay was developed to target the A. vasorum second internal transcribed spacer region and detected DNA in EDTA blood, lung tissue, broncho-alveolar larvage fluid, endotracheal mucus, pharyngeal swabs and faecal samples. PCR was fast (∼1 h), highly efficient when using EDTA blood samples, consistently detected a single molecule of parasite DNA and did not amplify DNA from other parasitic nematodes or definitive host species. An indirect ELISA was also developed using the soluble protein fraction from adult A. vasorum worms. Some cross-reactive antigen recognition was observed when tested against sera from dogs infected with Crenosoma vulpis (n = 8), Toxocara canis (n = 5) and Dirofilaria immitis (n = 5). This was largely overcome by setting the cut-off for a positive result at an appropriately high level. Field evaluation of the real-time PCR and ELISA was conducted by testing sera and EDTA blood from dogs with suspected A. vasorum infection (n = 148) and compared with the Baermann's larval migration test in faeces. Thirty-one dogs were positive by at least one test. Of these, 20 (65%) were detected by the Baermann method, 18 (58%) by blood PCR, 24 (77%) by ELISA and 28 (90%) by blood PCR and ELISA together. Combined testing using real-time PCR and ELISA therefore improved the detection rate of A. vasorum infection and holds promise for improved clinical diagnosis and epidemiological investigation.
Indirect Estimation of Radioactivity in Containerized Cargo
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jarman, Kenneth D.; Scherrer, Chad; Smith, Eric L.
Detecting illicit nuclear and radiological material in containerized cargo challenges the state of the art in detection systems. Current systems are being evaluated and new systems envisioned to address the need for the high probability of detection and extremely low false alarm rates necessary to thwart potential threats and extremely low nuisance and false alarm rates while maintaining necessary to maintain the flow of commerce impacted by the enormous volume of commodities imported in shipping containers. Maintaining flow of commerce also means that primary inspection must be rapid, requiring relatively indirect measurements of cargo from outside the containers. With increasingmore » information content in such indirect measurements, it is natural to ask how the information might be combined to improved detection. Toward this end, we present an approach to estimating isotopic activity of naturally occurring radioactive material in cargo grouped by commodity type, combining container manifest data with radiography and gamma spectroscopy aligned to location along the container. The heart of this approach is our statistical model of gamma counts within peak regions of interest, which captures the effects of background suppression, counting noise, convolution of neighboring cargo contributions, and down-scattered photons to provide physically constrained estimates of counts due to decay of specific radioisotopes in cargo alone. Coupled to that model, we use a mechanistic model of self-attenuated radiation flux to estimate the isotopic activity within cargo, segmented by location within each container, that produces those counts. We demonstrate our approach by applying it to a set of measurements taken at the Port of Seattle in 2006. This approach to synthesizing disparate available data streams and extraction of cargo characteristics holds the potential to improve primary inspection using current detection capabilities and to enable simulation-based evaluation of new candidate detection systems.« less
Antibody class capture assays for varicella-zoster virus.
Forghani, B; Myoraku, C K; Dupuis, K W; Schmidt, N J
1984-01-01
Pooled monoclonal antibodies to varicella-zoster virus (VZV) were used as "detector" antibodies in a four-phase enzyme immunofluorescence assay for determination of immunoglobulin M (IgM), IgA, and IgG antibodies to VZV. Polyclonal antisera specific for heavy chains of human IgM, IgA, and IgG were employed as "capture" antibodies on the solid phase. The antibody class capture assay (ACCA) for VZV IgM antibody detected high titers of virus-specific IgM in all patients with varicella and in 5 of 10 zoster patients. VZV IgM antibody was not detected in patients with primary herpes simplex virus infections or in other individuals without active VZV infection, with one exception, a patient with encephalitis who had other serological findings compatible with a reactivated VZV infection. VZV-specific IgA and IgG antibody titers demonstrable by ACCA were compared with those measured by solid-phase indirect enzyme immunofluorescence assay (EIFA). VZV IgA antibody titers detected in patients with varicella and zoster were variable and could not be considered to be reliable markers of active VZV infection. IgA antibody titers detected by ACCA tended to be higher than those demonstrated by solid-phase indirect EIFA in varicella and zoster patients. VZV IgG antibody titers detected by ACCA in patients with varicella, and to a lesser extent in zoster patients, were as high as or higher than those demonstrated by solid-phase indirect EIFA. However, ACCA was totally insensitive in detecting VZV IgG antibody in individuals with past infections with VZV and would not be a suitable approach for determination of immunity status to VZV. PMID:6330163
OMICS-strategies and methods in the fight against doping.
Reichel, Christian
2011-12-10
During the past decade OMICS-methods not only continued to have their impact on research strategies in life sciences and in particular molecular biology, but also started to be used for anti-doping control purposes. Research activities were mainly reasoned by the fact that several substances and methods, which were prohibited by the World Anti-Doping Agency (WADA), were or still are difficult to detect by direct methods. Transcriptomics, proteomics, and metabolomics in theory offer ideal platforms for the discovery of biomarkers for the indirect detection of the abuse of these substances and methods. Traditionally, the main focus of transcriptomics and proteomics projects has been on the prolonged detection of the misuse of human growth hormone (hGH), recombinant erythropoietin (rhEpo), and autologous blood transfusion. An additional benefit of the indirect or marker approach would also be that similarly acting substances might then be detected by a single method, without being forced to develop new direct detection methods for new but comparable prohibited substances (as has been the case, e.g. for the various forms of Epo analogs and biosimilars). While several non-OMICS-derived parameters for the indirect detection of doping are currently in use, for example the blood parameters of the hematological module of the athlete's biological passport, the outcome of most non-targeted OMICS-projects led to no direct application in routine doping control so far. The main reason is the inherent complexity of human transcriptomes, proteomes, and metabolomes and their inter-individual variability. The article reviews previous and recent research projects and their results and discusses future strategies for a more efficient application of OMICS-methods in doping control. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Development of a new first-aid biochemical detector
NASA Astrophysics Data System (ADS)
Hu, Jingfei; Liao, Haiyang; Su, Shilin; Ding, Hao; Liu, Suquan
2016-10-01
The traditional biochemical detector exhibits poor adaptability, inconvenient carrying and slow detection, which can't meet the needs of first-aid under field condition like natural or man-made disasters etc. Therefore a scheme of first-aid biochemical detector based on MOMES Micro Spectrometer, UV LED and Photodiode was proposed. An optical detection structure combined continuous spectrum sweep with fixed wavelength measurement was designed, which adopted mobile detection optical path consisting of Micro Spectrometer and Halogen Lamp to detect Chloride (Cl-), Creatinine (Cre), Glucose (Glu), Hemoglobin (Hb). The UV LED and Photodiode were designed to detect Potassium (K-), Carbon dioxide (CO2), Sodium (Na+). According to the field diagnosis and treatment requirements, we designed the embedded control hardware circuit and software system, the prototype of first-aid biochemical detector was developed and the clinical trials were conducted. Experimental results show that the sample's absorbance repeatability is less than 2%, the max coefficient of variation (CV) in the batch repeatability test of all 7 biochemical parameters in blood samples is 4.68%, less than the clinical requirements 10%, the correlation coefficient (R2) in the clinical contrast test with AU5800 is almost greater than 0.97. To sum up, the prototype meets the requirements of clinical application.
Direct and Indirect Dark Matter Detection in Gauge Theories (in Portuguese)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Queiroz, Farinaldo
The Dark matter (DM) problem constitutes a key question at the interface among Particle Physics, Astrophysics and Cosmology. The observational data which have been accumulated in the last years point to an existence of non baryonic amount of DM. Since the Standard Model (SM) does not provide any candidate for such non-baryonic DM, the evidence of DM is a major indication for new physics beyond the SM. We will study in this work one of the most popular DM candidates, the so called WIMPs (Weakly Interacting Massive Particles) from a direct and indirect detection perspective. In order to approach themore » direct and indirect dection of DM in the context of Particle Physics in a more pedagogic way, we will begin our discussion talking about a minimal extension of the SM. Later we will work on the subject in a 3-3-1 model. Next, we will study the role of WIMPs in the Big Bang Nucleosynthesis. Lastly, we will look for indirect DM signals in the center of our galaxy using the NASA Satellite, called Fermi-LAT. Through a comprehensive analysis of the data events observed by Fermi-LAT and some background models, we will constrain the dark matter annihilation cross section for several annihilation channels and dark matter halo profiles.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mao, Kanmi; Pruski, Marek
Two-dimensional through-bond {sup 1}H({sup 13}C) solid-state NMR experiments utilizing fast magic angle spinning (MAS) and homonuclear multipulse {sup 1}H decoupling are presented. Remarkable efficiency of polarization transfer can be achieved at MAS rates exceeding 40 kHz, which is instrumental in these measurements. Schemes utilizing direct and indirect detection of heteronuclei are compared in terms of resolution and sensitivity. A simple procedure for optimization of {sup 1}H homonuclear decoupling sequences under these conditions is proposed. The capabilities of these techniques were confirmed on two naturally abundant solids, tripeptide N-formyl-l-methionyl-l-leucyl-l-phenylalanine (f-MLF-OH) and brown coal.
NASA Astrophysics Data System (ADS)
Mao, Kanmi; Pruski, Marek
2009-12-01
Two-dimensional through-bond 1H{ 13C} solid-state NMR experiments utilizing fast magic angle spinning (MAS) and homonuclear multipulse 1H decoupling are presented. Remarkable efficiency of polarization transfer can be achieved at MAS rates exceeding 40 kHz, which is instrumental in these measurements. Schemes utilizing direct and indirect detection of heteronuclei are compared in terms of resolution and sensitivity. A simple procedure for optimization of 1H homonuclear decoupling sequences under these conditions is proposed. The capabilities of these techniques were confirmed on two naturally abundant solids, tripeptide N- formyl- L-methionyl- L-leucyl- L-phenylalanine (f-MLF-OH) and brown coal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mao, Kanmi
The development of fast magic angle spinning (MAS) opened up an opportunity for the indirect detection of insensitive low-γ nuclei (e.g., 13C and 15N) via the sensitive high-{gamma} nuclei (e.g., 1H and 19F) in solid-state NMR, with advanced sensitivity and resolution. In this thesis, new methodology utilizing fast MAS is presented, including through-bond indirectly detected heteronuclear correlation (HETCOR) spectroscopy, which is assisted by multiple RF pulse sequences for 1H- 1H homonuclear decoupling. Also presented is a simple new strategy for optimization of 1H- 1H homonuclear decoupling. As applications, various classes of materials, such as catalytic nanoscale materials, biomolecules, and organic complexes, are studied by combining indirect detection and other one-dimensional (1D) and two-dimensional (2D) NMR techniques. Indirectly detected through-bond HETCOR spectroscopy utilizing refocused INEPT (INEPTR) mixing was developed under fast MAS (Chapter 2). The time performance of this approach in 1H detected 2D 1H{l_brace} 13C{r_brace} spectra was significantly improved, by a factor of almost 10, compared to the traditional 13C detected experiments, as demonstrated by measuring naturally abundant organic-inorganic mesoporous hybrid materials. The through-bond scheme was demonstrated as a new analytical tool, which provides complementary structural information in solid-state systems in addition to through-space correlation. To further benefit the sensitivity of the INEPT transfer in rigid solids, the combined rotation and multiple-pulse spectroscopy (CRAMPS) was implemented for homonuclear 1H decoupling under fast MAS (Chapter 3). Several decoupling schemes (PMLG5 m more » $$\\bar{x}$$, PMLG5 mm $$\\bar{x}$$x and SAM3) were analyzed to maximize the performance of through-bond transfer based on decoupling efficiency as well as scaling factors. Indirect detection with assistance of PMLG m $$\\bar{x}$$ during INEPTR transfer proved to offer the highest sensitivity gains of 3-10. In addition, the CRAMPS sequence was applied under fast MAS to increase the 1H resolution during t 1 evolution in the traditional, 13C detected HETCOR scheme. Two naturally abundant solids, tripeptide N-formyl-L-methionyl-L-leucyl-L-phenylalanine (f-MLF-OH) and brown coal, with well ordered and highly disordered structures, respectively, are studied to confirm the capabilities of these techniques. Concomitantly, a simple optimization of 1H homonuclear dipolar decoupling at MAS rates exceeding 10 kHz was developed (Chapter 4). The fine-tuned decoupling efficiency can be obtained by minimizing the signal loss due to transverse relaxation in a simple spin-echo experiment, using directly the sample of interest. The excellent agreement between observed decoupling pattern and earlier theoretical predictions confirmed the utility of this strategy. The properties of naturally abundant surface-bound fluorocarbon groups in mesoporous silica nanoparticles (MSNs) were investigated by the above-mentioned multidimensional solid-state NMR experiments and theoretical modeling (Chapter 5). Two conformations of (pentafluorophenyl)propyl groups (abbreviated as PFP) were determined as PFP-prone and PFP-upright, whose aromatic rings are located above the siloxane bridges and in roughly upright position, respectively. Several 1D and 2D NMR techniques were implemented in the characterizations, including indirectly detected 1H{l_brace} 13C{r_brace} and 19F{l_brace} 13C{r_brace} 2D HETCOR, Carr-Purcell-Meiboom-Gill (CPMG) assisted 29Si direct polarization and 29Si 19F 2D experiments, 2D double-quantum (DQ) 19F MAS NMR spectra and spin-echo measurements. Furthermore, conformational details of two types of PFP were confirmed by theoretical calculation, operated by Dr. Takeshi Kobayashi. Finally, the arrangement of two surfactants, cetyltrimetylammoium bromide (CTAB) and cetylpyridinium bromide (CPB), mixed inside the MSN pores, was studied by solid-state NMR (Chapter 6). By analyzing the 1H- 1H DQMAS and NOESY correlation spectra, the CTAB and CPB molecules were shown to co-exist inside the pores without forming significant monocomponent domains. A 'folded-over' conformation of CPB headgroups was proposed according to the results from 1H- 29Si 2D HETCOR.« less
Circulation and Purification in the LUX-ZEPLIN System Test
NASA Astrophysics Data System (ADS)
Alsum, Shaun; Lz Collaboration
2016-03-01
LZ is a dark-matter direct detection experiment whose detector is a two-phase TPC using approximately seven tons of active xenon as its scintillator. The xenon must have few electronegative impurities to ensure sufficient electron transport through the drift region. The LZ purification system is being prototyped in the LZ system test, a test platform located at SLAC using about 100kg of Xenon, which consists of gas circulation through a SAES getter. We utilize a dual-phase and a gas-phase heat exchanger to reduce needed cooling power. To achieve this circulation we employ an all metal seal triple diaphragm pump, also prototyped in the System Test. This talk will present early results from the system test as well as some baseline LZ designs. The LUX-ZEPLIN dark matter direct detection experiment.
NASA Astrophysics Data System (ADS)
Kitsara, Maria; Cirera, Josep Maria; Aller-Pellitero, Miguel; Sabaté, Neus; Punter, Jaume; Colomer-Farrarons, Jordi; Miribel-Català, Pere; del Campo, F. Javier
2015-06-01
The development of a low-cost multiparametric platform for enzymatic electrochemical biosensing that can be integrated in a disposable, energy autonomous analytical device is the target of the current work. We propose a technology to fabricate nano-electrodes and ultimately biosensors on flexible polymeric-based substrates (cyclo olefin polymer, and polyimide) using standard microfabrication (step and repeat lithography and lift-off) and rapid prototyping techniques (blade cutting). Our target is towards the fabrication of a miniaturized prototype that can work with small sample volumes in the range of 5-10μL without the need for external pumps for sample loading and handling. This device can be used for the simultaneous detection of metabolites such as glucose, cholesterol and triglycerides for the early diagnosis of diabetes.
USDA-ARS?s Scientific Manuscript database
Infectious agents or their constituent parts (antigens or nucleic acids) can be detected in fresh, frozen, or fixed tissues or other specimens, using a variety of direct or indirect assays. The assays can be modified to yield the greatest sensitivity and specificity but in most cases a particular m...
DOT National Transportation Integrated Search
2014-08-01
A proof of concept was established for a sensor capable of using indirect impedance spectroscopy to : detect the existence of corrosion in post-tensioned tendons. This development was supported by a : combination of bench-top experiments performed on...
Jankásková, J; Horváth, O N; Varga, R; Arenberger, P; Schmidt, E; Ruzicka, T; Sárdy, M
2018-04-01
Indirect immunofluorescence (IIF) microscopy on monkey oesophagus is an important assay for the diagnosis of bullous pemphigoid (BP). Its relatively low sensitivity (60-80%) may be partly due to insufficient detection of minor IgG subclasses. To determine the operating characteristics of an IgG subclass in IIF. We designed a retrospective, dual-centre, controlled cohort study on sera from 64 BP sera that had been rated as false negatives by traditional IIF microscopy, and assessed circulating IgG 1 , IgG 3 and IgG 4 autoantibodies. The sensitivities of IIF in detecting IgG 1 , IgG 3 , IgG 4 and all three in combination were 45.3%, 18.8%, 32.8% and 48.4%, respectively. Specificities were > 97%. Detection of IgG subclass (especially IgG 1 and IgG 4 ) autoantibodies by IIF on monkey oesophagus can significantly improve diagnostic performance of IIF microscopy for diagnosis of BP. © 2018 British Association of Dermatologists.
Progress In The Development Of A Tomographic SPECT System For Online Dosimetry In BNCT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Minsky, D. M.; Kreiner, A. J.; ECyT, UNSAM, M. de Irigoyen 3100
2010-08-04
In boron neutron capture therapy (BNCT) the delivered dose to the patient depends both on the neutron beam characteristics and on the {sup 10}B body distribution which, in turn, is governed by the tumor specificity of the {sup 10}B drug-carrier. BNCT dosimetry is a complex matter due to the several interactions that neutrons can undergo with the different nuclei present in tissue. However the boron capture reaction {sup 10}B(n,{alpha}){sup 7}Li accounts for about 80 % of the total dose in a tumor with 40 ppm in {sup 10}B concentration. Present dosimetric methods are indirect, based on drug biodistribution statistical datamore » and subjected to inter and intra-patient variability. In order to overcome the consequences of the concomitant high dosimetric uncertainties, we propose a SPECT (Single Photon Emission Tomography) approach based on the detection of the prompt gamma-ray (478 keV) emitted in 94 % of the cases from {sup 7}Li. For this purpose we designed, built and tested a prototype based on LaBr{sub 3}(Ce) scintillators. Measurements on a head and tumor phantom were performed in the accelerator-based BNCT facility of the University of Birmingham (UK). They result in the first tomographic image of the 10B capture distribution obtained in a BNCT facility.« less
Toward Exposing Timing-Based Probing Attacks in Web Applications †
Mao, Jian; Chen, Yue; Shi, Futian; Jia, Yaoqi; Liang, Zhenkai
2017-01-01
Web applications have become the foundation of many types of systems, ranging from cloud services to Internet of Things (IoT) systems. Due to the large amount of sensitive data processed by web applications, user privacy emerges as a major concern in web security. Existing protection mechanisms in modern browsers, e.g., the same origin policy, prevent the users’ browsing information on one website from being directly accessed by another website. However, web applications executed in the same browser share the same runtime environment. Such shared states provide side channels for malicious websites to indirectly figure out the information of other origins. Timing is a classic side channel and the root cause of many recent attacks, which rely on the variations in the time taken by the systems to process different inputs. In this paper, we propose an approach to expose the timing-based probing attacks in web applications. It monitors the browser behaviors and identifies anomalous timing behaviors to detect browser probing attacks. We have prototyped our system in the Google Chrome browser and evaluated the effectiveness of our approach by using known probing techniques. We have applied our approach on a large number of top Alexa sites and reported the suspicious behavior patterns with corresponding analysis results. Our theoretical analysis illustrates that the effectiveness of the timing-based probing attacks is dramatically limited by our approach. PMID:28245610
Toward Exposing Timing-Based Probing Attacks in Web Applications.
Mao, Jian; Chen, Yue; Shi, Futian; Jia, Yaoqi; Liang, Zhenkai
2017-02-25
Web applications have become the foundation of many types of systems, ranging from cloud services to Internet of Things (IoT) systems. Due to the large amount of sensitive data processed by web applications, user privacy emerges as a major concern in web security. Existing protection mechanisms in modern browsers, e.g., the same origin policy, prevent the users' browsing information on one website from being directly accessed by another website. However, web applications executed in the same browser share the same runtime environment. Such shared states provide side channels for malicious websites to indirectly figure out the information of other origins. Timing is a classic side channel and the root cause of many recent attacks, which rely on the variations in the time taken by the systems to process different inputs. In this paper, we propose an approach to expose the timing-based probing attacks in web applications. It monitors the browser behaviors and identifies anomalous timing behaviors to detect browser probing attacks. We have prototyped our system in the Google Chrome browser and evaluated the effectiveness of our approach by using known probing techniques. We have applied our approach on a large number of top Alexa sites and reported the suspicious behavior patterns with corresponding analysis results. Our theoretical analysis illustrates that the effectiveness of the timing-based probing attacks is dramatically limited by our approach.
Solar drying of whole mint plant under natural and forced convection
Sallam, Y.I.; Aly, M.H.; Nassar, A.F.; Mohamed, E.A.
2013-01-01
Two identical prototype solar dryers (direct and indirect) having the same dimensions were used to dry whole mint. Both prototypes were operated under natural and forced convection modes. In the case of the later one the ambient air was entered the dryer with the velocity of 4.2 m s−1. The effect of flow mode and the type of solar dryers on the drying kinetics of whole mint were investigated. Ten empirical models were used to fit the drying curves; nine of them represented well the solar drying behavior of mint. The results indicated that drying of mint under different operating conditions occurred in the falling rate period, where no constant rate period of drying was observed. Also, the obtained data revealed that the drying rate of mint under forced convection was higher than that of mint under natural convection, especially during first hours of drying (first day). The values of the effective diffusivity coefficient for the mint drying ranged between 1.2 × 10−11 and 1.33 × 10−11 m2 s−1. PMID:25750751
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fabbricatore, P.; Ambrosio, G.; Cheban, S.
The Mu2e Transport Solenoid consists of 52 coils arranged in 27 coil modules that form the S-shaped cold mass. Each coil is wound from Al-stabilized NbTi superconductor. The coils are supported by an external structural aluminum shell machined from a forged billet. Most of the coil modules house two coils, with the axis of each coil oriented at an angle of approximately 5° with respect to each other. The coils are indirectly cooled with LHe circulating in tubes welded on the shell. In order to enhance the cooling capacity, pure aluminum sheets connect the inner bore of the coils tomore » the cooling tubes. The coils are placed inside the shell by the means of a shrink-fit procedure. A full-size prototype, with all the features of the full assembly, was successfully manufactured in a collaboration between INFN Genova and Fermilab. In order to ensure an optimal mechanical prestress at the coil-shell interface, the coils are inserted into the shell through a shrink-fitting process. We present the details of the prototype with the design choices as validated by the structural analysis. In conclusion, the fabrication steps are described as well.« less
Detection of Oil in Water Column, Final Report: Detection Prototype Tests
2014-07-01
first phase of the project involved initial development and testing of three technologies to address the detection problem . This second phase...important oceanic phenomena such as density stratification and naturally occurring particulate matter, which will affect the performance of sensors in the ...2 UNCLAS//Public | CG-926 RDC | M. Fitzpatrick, et al.| Public July 2014 spills of submerged oil is far more complex due to the problems
NASA Astrophysics Data System (ADS)
Ingram, Russ; Sikes, John
2010-04-01
This paper shall demonstrate the results of a prototype system to detect explosive objects and obscured contaminated targets. By combining a high volume sampling nozzle with an inline 2-stage preconcentrator and a Fido, greater standoff is achieved than with the Fido alone. The direct application of this system is on the Autonomous Mine Detection System (AMDS) but could be deployed on a large variety of robotic platforms. It is being developed under the auspices of the U.S. Army RDECOM CERDEC Night Vision and Electronic Sensors Directorate, Countermine Division. This device is one of several detection tools and technologies to be used on the AMDS. These systems will have multiple, and at times, overlapping objectives. One objective is trace detection on the surface of an unknown potential target. By increasing the standoff capabilities of the detector, the fine manipulation of the robot deploying the detector is less critical. Current detectors used on robotic systems must either be directly in the vapor plume or make direct contact with the target. By increasing the standoff, detection is more easily and quickly achieved. The end result detector must overcome cross-contamination, sample throughput, and environmental issues. The paper will provide preliminary results of the prototype system to include data, and where feasible, video of testing results.
Electrophoresis-chemiluminescence detection of phenols catalyzed by hemin.
Shu, Lu; Zhu, Jinkun; Wang, Qingjiang; He, Pingang; Fang, Yuzhi
2014-09-01
Based on the catalytic activity of hemin, an efficient biocatalyst, an indirect capillary electrophoresis-chemiluminescence (CE-CL) detection method for phenols using a hemin-luminol-hydrogen peroxide system was developed. Through a series of static injection experiments, hemin was found to perform best in a neutral solution rather than an acidic or alkaline medium. Although halide ions such as Br(-) and F(-) could further enhance the CL signal catalyzed by hemin, it is difficult to apply these conditions to this CE-CL detection system because of the self-polymerization of hemin, as it hinders the CE process. The addition of concentrated ammonium hydroxide to an aqueous/dimethyl sulfoxide solution of hemin-luminol afforded a stable CE-CL baseline. The indirect CE-CL detection of five phenols using this method gave the following limits of detections: 4.8 × 10(-8) mol/L (o-sec-butylphenol), 4.9 × 10(-8) mol/L (o-cresol), 5.4 × 10(-8) mol/L (m-cresol), 5.3 × 10(-8) mol/L (2,4-dichlorophenol) and 7.1 × 10(-8) mol/L (phenol). Copyright © 2013 John Wiley & Sons, Ltd.
Besuschio, Susana A; Llano Murcia, Mónica; Benatar, Alejandro F; Monnerat, Severine; Cruz, Israel; Picado, Albert; Curto, María de Los Ángeles; Kubota, Yutaka; Wehrendt, Diana P; Pavia, Paula; Mori, Yasuyoshi; Puerta, Concepción; Ndung'u, Joseph M; Schijman, Alejandro G
2017-07-01
This study aimed to assess analytical parameters of a prototype LAMP kit that was designed for detection of Trypanosoma cruzi DNA in human blood. The prototype is based on the amplification of the highly repetitive satellite sequence of T.cruzi in microtubes containing dried reagents on the inside of the caps. The reaction is carried out at 65°C during 40 minutes. Calcein allows direct detection of amplified products with the naked eye. Inclusivity and selectivity were tested in purified DNA from Trypanosoma cruzi stocks belonging to the six discrete typing units (DTUs), in DNA from other protozoan parasites and in human DNA. Analytical sensitivity was estimated in serial dilutions of DNA samples from Sylvio X10 (Tc I) and CL Brener (Tc VI) stocks, as well as from EDTA-treated or heparinized blood samples spiked with known amounts of cultured epimastigotes (CL Brener). LAMP sensitivity was compared after DNA extraction using commercial fiberglass columns or after "Boil & Spin" rapid preparation. Moreover, the same DNA and EDTA-blood spiked samples were subjected to standardized qPCR based on the satellite DNA sequence for comparative purposes. A panel of peripheral blood specimens belonging to Chagas disease patients, including acute, congenital, chronic and reactivated cases (N = 23), as well as seronegative controls (N = 10) were evaluated by LAMP in comparison to qPCR. LAMP was able to amplify DNAs from T. cruzi stocks representative of the six DTUs, whereas it did not amplify DNAs from Leishmania sp, T. brucei sp, T. rangeli KPN+ and KPN-, P. falciparum and non-infected human DNA. Analytical sensitivity was 1x10-2 fg/μL of both CL Brener and Sylvio X10 DNAs, whereas qPCR detected up to 1x 10-1 fg/μL of CL Brener DNA and 1 fg/μl of Sylvio X10 DNA. LAMP detected 1x10-2 parasite equivalents/mL in spiked EDTA blood and 1x10-1 par.eq/mL in spiked heparinized blood using fiberglass columns for DNA extraction, whereas qPCR detected 1x10-2 par.eq./mL in EDTA blood. Boil & Spin extraction allowed detection of 1x10-2 par.eq /mL in spiked EDTA blood and 1 par.eq/ml in heparinized blood. LAMP was able to detect T.cruzi infection in peripheral blood samples collected from well-characterised seropositive patients, including acute, congenital, chronic and reactivated Chagas disease. To our knowledge, this is the first report of a prototype LAMP kit with appropriate analytical sensitivity for diagnosis of Chagas disease patients, and potentially useful for monitoring treatment response.
Besuschio, Susana A.; Llano Murcia, Mónica; Benatar, Alejandro F.; Monnerat, Severine; Cruz, Israel; Picado, Albert; Curto, María de los Ángeles; Kubota, Yutaka; Wehrendt, Diana P.; Pavia, Paula; Mori, Yasuyoshi; Puerta, Concepción; Ndung'u, Joseph M.
2017-01-01
This study aimed to assess analytical parameters of a prototype LAMP kit that was designed for detection of Trypanosoma cruzi DNA in human blood. The prototype is based on the amplification of the highly repetitive satellite sequence of T.cruzi in microtubes containing dried reagents on the inside of the caps. The reaction is carried out at 65°C during 40 minutes. Calcein allows direct detection of amplified products with the naked eye. Inclusivity and selectivity were tested in purified DNA from Trypanosoma cruzi stocks belonging to the six discrete typing units (DTUs), in DNA from other protozoan parasites and in human DNA. Analytical sensitivity was estimated in serial dilutions of DNA samples from Sylvio X10 (Tc I) and CL Brener (Tc VI) stocks, as well as from EDTA-treated or heparinized blood samples spiked with known amounts of cultured epimastigotes (CL Brener). LAMP sensitivity was compared after DNA extraction using commercial fiberglass columns or after “Boil & Spin” rapid preparation. Moreover, the same DNA and EDTA-blood spiked samples were subjected to standardized qPCR based on the satellite DNA sequence for comparative purposes. A panel of peripheral blood specimens belonging to Chagas disease patients, including acute, congenital, chronic and reactivated cases (N = 23), as well as seronegative controls (N = 10) were evaluated by LAMP in comparison to qPCR. LAMP was able to amplify DNAs from T. cruzi stocks representative of the six DTUs, whereas it did not amplify DNAs from Leishmania sp, T. brucei sp, T. rangeli KPN+ and KPN-, P. falciparum and non-infected human DNA. Analytical sensitivity was 1x10-2 fg/μL of both CL Brener and Sylvio X10 DNAs, whereas qPCR detected up to 1x 10−1 fg/μL of CL Brener DNA and 1 fg/μl of Sylvio X10 DNA. LAMP detected 1x10-2 parasite equivalents/mL in spiked EDTA blood and 1x10-1 par.eq/mL in spiked heparinized blood using fiberglass columns for DNA extraction, whereas qPCR detected 1x10-2 par.eq./mL in EDTA blood. Boil & Spin extraction allowed detection of 1x10-2 par.eq /mL in spiked EDTA blood and 1 par.eq/ml in heparinized blood. LAMP was able to detect T.cruzi infection in peripheral blood samples collected from well-characterised seropositive patients, including acute, congenital, chronic and reactivated Chagas disease. To our knowledge, this is the first report of a prototype LAMP kit with appropriate analytical sensitivity for diagnosis of Chagas disease patients, and potentially useful for monitoring treatment response. PMID:28727723
NASA Astrophysics Data System (ADS)
Carnevale, Diego; Ji, Xiao; Bodenhausen, Geoffrey
2017-11-01
Nitrogen-14 NMR spectra at fast magic-angle spinning rates can be acquired indirectly by means of two-dimensional techniques based on double cross polarization transfer 1H → 14N →1H. Experimental evidence is given for polycrystalline samples of glycine, l-histidine, and the dipeptide Ala-Gly. Either one-bond or long-range correlations can be favored by choosing the length of the cross polarization contact pulses. Longer contact pulses allow the detection of unprotonated nitrogen sites. In contrast to earlier methods that exploited second-order quadrupolar/dipolar cross-terms, cross polarization operates in the manner of the method of Hartmann and Hahn, even for 14N quadrupolar couplings up to 4 MHz. Simulations explain why amorphous samples tend to give rise to featureless spectra because the 14N quadrupolar interactions may vary dramatically with the lattice environment. The experiments are straightforward to set up and are shown to be effective for different nitrogen environments and robust with respect to the rf-field strengths and to the 14N carrier frequency during cross polarization. The efficiency of indirect detection of 14N nuclei by double cross polarization is shown to be similar to that of isotopically enriched 13C nuclei.
Sensing Methods for Detecting Analog Television Signals
NASA Astrophysics Data System (ADS)
Rahman, Mohammad Azizur; Song, Chunyi; Harada, Hiroshi
This paper introduces a unified method of spectrum sensing for all existing analog television (TV) signals including NTSC, PAL and SECAM. We propose a correlation based method (CBM) with a single reference signal for sensing any analog TV signals. In addition we also propose an improved energy detection method. The CBM approach has been implemented in a hardware prototype specially designed for participating in Singapore TV white space (WS) test trial conducted by Infocomm Development Authority (IDA) of the Singapore government. Analytical and simulation results of the CBM method will be presented in the paper, as well as hardware testing results for sensing various analog TV signals. Both AWGN and fading channels will be considered. It is shown that the theoretical results closely match with those from simulations. Sensing performance of the hardware prototype will also be presented in fading environment by using a fading simulator. We present performance of the proposed techniques in terms of probability of false alarm, probability of detection, sensing time etc. We also present a comparative study of the various techniques.
NEN Division Funding Gap Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Esch, Ernst I.; Goettee, Jeffrey D.; Desimone, David J.
The work in NEN Division revolves around proliferation detection. The sponsor funding model seems to have shifted over the last decades. For the past three lustra, sponsors are mainly interested in funding ideas and detection systems that are already at a technical readiness level 6 (TRL 6 -- one step below an industrial prototype) or higher. Once this level is reached, the sponsoring agency is willing to fund the commercialization, implementation, and training for the systems (TRL 8, 9). These sponsors are looking for a fast turnaround (1-2 years) technology development efforts to implement technology. To support the critical nationalmore » and international needs for nonprolifertion solutions, we have to maintain a fluent stream of subject matter expertise from the fundamental principals of radiation detection through prototype development all the way to the implementation and training of others. NEN Division has large funding gaps in the Valley of Death region. In the current competitive climate for nuclear nonproliferation projects, it is imminent to increase our lead in this field.« less
Dwivedi, Priyanka; Dhanekar, Saakshi; Das, Samaresh
2018-07-06
This paper presents the development of an extremely sensitive and selective acetone sensor prototype which can be used as a platform for non-invasive diabetes detection through exhaled human breath. The miniaturized sensors were produced in high yield with the use of standard microfabrication processes. The sensors were based on a heterostructure composed of MoO 3 and nano-porous silicon (NPS). Features like acetone selective, enhanced sensor response and 0.5 ppm detection limit were observed upon introduction of MoO 3 on the NPS. The sensors were found to be repeatable and stable for almost 1 year, as tested under humid conditions at room temperature. It was inferred that the interface resistance of MoO 3 and NPS played a key role in the sensing mechanism. With the use of breath analysis and lab-on-chip, medical diagnosis procedures can be simplified and provide solutions for point-of-care testing.
Novel method for detecting weak magnetic fields at low frequencies
NASA Astrophysics Data System (ADS)
González-Martínez, S.; Castillo-Torres, J.; Mendoza-Santos, J. C.; Zamorano-Ulloa, R.
2005-06-01
A low-level-intensity magnetic field detection system has been designed and developed based on the amplification-selection process of signals. This configuration is also very sensitive to magnetic field changes produced by harmonic-like electrical currents transported in finite-length wires. Experimental and theoretical results of magnetic fields detection as low as 10-9T at 120Hz are also presented with an accuracy of around 13%. The assembled equipment is designed to measure an electromotive force induced in a free-magnetic-core coil in order to recover signals which are previously selected, despite the fact that their intensities are much lower than the environment electromagnetic radiation. The prototype has a signal-to-noise ratio of 60dB. This system also presents the advantage for using it as a portable unit of measurement. The concept and prototype may be applied, for example, as a nondestructive method to analyze any corrosion formation in metallic oil pipelines which are subjected to cathodic protection.
Design, fabrication, and verification of a three-dimensional autocollimator.
Yin, Yanhe; Cai, Sheng; Qiao, Yanfeng
2016-12-10
The autocollimator is an optical instrument for noncontact angle measurement with high resolution and a long detection range. It measures two-dimensional angles, i.e., pitch and yaw, but not roll. In this paper, we present a novelly structured autocollimator capable of measuring three-dimensional (3D) angles simultaneously. In this setup, two collimated beams of different wavelengths are projected onto a right-angle prism. One beam is reflected by the hypotenuse of the prism and received by an autocollimation unit for detecting pitch and yaw. The other is reflected by the two legs of the right-angle prism and received by a moiré fringe imaging unit for detecting roll. Furthermore, a prototype is designed and fabricated. Experiments are carried out to evaluate its basic performance. Calibration results show that this prototype has angular RMS errors of less than 5 arcsec in all 3Ds over a range of 1000 arcsec at a working distance of 2 m.
El-Mohri, Youcef; Antonuk, Larry E.; Koniczek, Martin; Zhao, Qihua; Li, Yixin; Street, Robert A.; Lu, Jeng-Ping
2009-01-01
Active matrix, flat-panel imagers (AMFPIs) employing a 2D matrix of a-Si addressing TFTs have become ubiquitous in many x-ray imaging applications due to their numerous advantages. However, under conditions of low exposures and∕or high spatial resolution, their signal-to-noise performance is constrained by the modest system gain relative to the electronic additive noise. In this article, a strategy for overcoming this limitation through the incorporation of in-pixel amplification circuits, referred to as active pixel (AP) architectures, using polycrystalline-silicon (poly-Si) TFTs is reported. Compared to a-Si, poly-Si offers substantially higher mobilities, enabling higher TFT currents and the possibility of sophisticated AP designs based on both n- and p-channel TFTs. Three prototype indirect detection arrays employing poly-Si TFTs and a continuous a-Si photodiode structure were characterized. The prototypes consist of an array (PSI-1) that employs a pixel architecture with a single TFT, as well as two arrays (PSI-2 and PSI-3) that employ AP architectures based on three and five TFTs, respectively. While PSI-1 serves as a reference with a design similar to that of conventional AMFPI arrays, PSI-2 and PSI-3 incorporate additional in-pixel amplification circuitry. Compared to PSI-1, results of x-ray sensitivity demonstrate signal gains of ∼10.7 and 20.9 for PSI-2 and PSI-3, respectively. These values are in reasonable agreement with design expectations, demonstrating that poly-Si AP circuits can be tailored to provide a desired level of signal gain. PSI-2 exhibits the same high levels of charge trapping as those observed for PSI-1 and other conventional arrays employing a continuous photodiode structure. For PSI-3, charge trapping was found to be significantly lower and largely independent of the bias voltage applied across the photodiode. MTF results indicate that the use of a continuous photodiode structure in PSI-1, PSI-2, and PSI-3 results in optical fill factors that are close to unity. In addition, the greater complexity of PSI-2 and PSI-3 pixel circuits, compared to that of PSI-1, has no observable effect on spatial resolution. Both PSI-2 and PSI-3 exhibit high levels of additive noise, resulting in no net improvement in the signal-to-noise performance of these early prototypes compared to conventional AMFPIs. However, faster readout rates, coupled with implementation of multiple sampling protocols allowed by the nondestructive nature of pixel readout, resulted in a significantly lower noise level of ∼560 e (rms) for PSI-3. PMID:19673229
El-Mohri, Youcef; Antonuk, Larry E; Koniczek, Martin; Zhao, Qihua; Li, Yixin; Street, Robert A; Lu, Jeng-Ping
2009-07-01
Active matrix, flat-panel imagers (AMFPIs) employing a 2D matrix of a-Si addressing TFTs have become ubiquitous in many x-ray imaging applications due to their numerous advantages. However, under conditions of low exposures and/or high spatial resolution, their signal-to-noise performance is constrained by the modest system gain relative to the electronic additive noise. In this article, a strategy for overcoming this limitation through the incorporation of in-pixel amplification circuits, referred to as active pixel (AP) architectures, using polycrystalline-silicon (poly-Si) TFTs is reported. Compared to a-Si, poly-Si offers substantially higher mobilities, enabling higher TFT currents and the possibility of sophisticated AP designs based on both n- and p-channel TFTs. Three prototype indirect detection arrays employing poly-Si TFTs and a continuous a-Si photodiode structure were characterized. The prototypes consist of an array (PSI-1) that employs a pixel architecture with a single TFT, as well as two arrays (PSI-2 and PSI-3) that employ AP architectures based on three and five TFTs, respectively. While PSI-1 serves as a reference with a design similar to that of conventional AMFPI arrays, PSI-2 and PSI-3 incorporate additional in-pixel amplification circuitry. Compared to PSI-1, results of x-ray sensitivity demonstrate signal gains of approximately 10.7 and 20.9 for PSI-2 and PSI-3, respectively. These values are in reasonable agreement with design expectations, demonstrating that poly-Si AP circuits can be tailored to provide a desired level of signal gain. PSI-2 exhibits the same high levels of charge trapping as those observed for PSI-1 and other conventional arrays employing a continuous photodiode structure. For PSI-3, charge trapping was found to be significantly lower and largely independent of the bias voltage applied across the photodiode. MTF results indicate that the use of a continuous photodiode structure in PSI-1, PSI-2, and PSI-3 results in optical fill factors that are close to unity. In addition, the greater complexity of PSI-2 and PSI-3 pixel circuits, compared to that of PSI-1, has no observable effect on spatial resolution. Both PSI-2 and PSI-3 exhibit high levels of additive noise, resulting in no net improvement in the signal-to-noise performance of these early prototypes compared to conventional AMFPIs. However, faster readout rates, coupled with implementation of multiple sampling protocols allowed by the nondestructive nature of pixel readout, resulted in a significantly lower noise level of approximately 560 e (rms) for PSI-3.
Logistics Reduction and Repurposing Technology for Long Duration Space Missions
NASA Technical Reports Server (NTRS)
Broyan, James Lee, Jr.; Chu, Andrew; Ewert, Michael K.
2014-01-01
One of NASA's Advanced Exploration Systems (AES) projects is the Logistics Reduction and Repurposing (LRR) project, which has the goal of reducing logistics resupply items through direct and indirect means. Various technologies under development in the project will reduce the launch mass of consumables and their packaging, enable reuse and repurposing of items, and make logistics tracking more efficient. Repurposing also reduces the trash burden onboard spacecraft and indirectly reduces launch mass by one manifest item having two purposes rather than two manifest items each having only one purpose. This paper provides the status of each of the LRR technologies in their third year of development under AES. Advanced clothing systems (ACSs) are being developed to enable clothing to be worn longer, directly reducing launch mass. ACS has completed a ground exercise clothing study in preparation for an International Space Station technology demonstration in 2014. Development of launch packaging containers and other items that can be repurposed on-orbit as part of habitation outfitting has resulted in a logistics-to-living (L2L) concept. L2L has fabricated and evaluated several multi-purpose cargo transfer bags for potential reuse on-orbit. Autonomous logistics management is using radio frequency identification (RFID) to track items and thus reduce crew time for logistics functions. An RFID dense reader prototype is under construction and plans for integrated testing are being made. A heat melt compactor (HMC) second generation unit for processing trash into compact and stable tiles is nearing completion. The HMC prototype compaction chamber has been completed and system development testing is under way. Research has been conducted on the conversion of trash-to-gas (TtG) for high levels of volume reduction and for use in propulsion systems. A steam reformation system was selected for further system definition of the TtG technology.
Logistics Reduction and Repurposing Technology for Long Duration Space Missions
NASA Technical Reports Server (NTRS)
Broyan, James L.; Chu, Andrew; Ewert, Michael K.
2014-01-01
One of NASA's Advanced Exploration Systems (AES) projects is the Logistics Reduction and Repurposing (LRR) project, which has the goal of reducing logistics resupply items through direct and indirect means. Various technologies under development in the project will reduce the launch mass of consumables and their packaging, enable reuse and repurposing of items and make logistics tracking more efficient. Repurposing also reduces the trash burden onboard spacecraft and indirectly reduces launch mass by replacing some items on the manifest. Examples include reuse of trash as radiation shielding or propellant. This paper provides the status of the LRR technologies in their third year of development under AES. Advanced clothing systems (ACS) are being developed to enable clothing to be worn longer, directly reducing launch mass. ACS has completed a ground exercise clothing study in preparation for an International Space Station (ISS) technology demonstration in 2014. Development of launch packaging containers and other items that can be repurposed on-orbit as part of habitation outfitting has resulted in a logistics-to-living (L2L) concept. L2L has fabricated and evaluated several multi-purpose cargo transfer bags (MCTBs) for potential reuse on orbit. Autonomous logistics management (ALM) is using radio frequency identification (RFID) to track items and thus reduce crew requirements for logistics functions. An RFID dense reader prototype is under construction and plans for integrated testing are being made. Development of a heat melt compactor (HMC) second generation unit for processing trash into compact and stable tiles is nearing completion. The HMC prototype compaction chamber has been completed and system development testing is underway. Research has been conducted on the conversion of trash-to-gas (TtG) for high levels of volume reduction and for use in propulsion systems. A steam reformation system was selected for further system definition of the TtG technology. And benefits analysis of all LRR technologies have been updated with the latest test and analysis results.
Current and Prospective Methods for Plant Disease Detection
Fang, Yi; Ramasamy, Ramaraja P.
2015-01-01
Food losses due to crop infections from pathogens such as bacteria, viruses and fungi are persistent issues in agriculture for centuries across the globe. In order to minimize the disease induced damage in crops during growth, harvest and postharvest processing, as well as to maximize productivity and ensure agricultural sustainability, advanced disease detection and prevention in crops are imperative. This paper reviews the direct and indirect disease identification methods currently used in agriculture. Laboratory-based techniques such as polymerase chain reaction (PCR), immunofluorescence (IF), fluorescence in-situ hybridization (FISH), enzyme-linked immunosorbent assay (ELISA), flow cytometry (FCM) and gas chromatography-mass spectrometry (GC-MS) are some of the direct detection methods. Indirect methods include thermography, fluorescence imaging and hyperspectral techniques. Finally, the review also provides a comprehensive overview of biosensors based on highly selective bio-recognition elements such as enzyme, antibody, DNA/RNA and bacteriophage as a new tool for the early identification of crop diseases. PMID:26287253
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roszkowski, Leszek; Trojanowski, Sebastian; Turzyński, Krzysztof, E-mail: leszek.roszkowski@ncbj.gov.pl, E-mail: sebastian.trojanowski@uci.edu, E-mail: Krzysztof-Jan.Turzynski@fuw.edu.pl
We examine the question to what extent prospective detection of dark matter by direct and indirect- detection experiments could shed light on what fraction of dark matter was generated thermally via the freeze-out process in the early Universe. By simulating putative signals that could be seen in the near future and using them to reconstruct WIMP dark matter properties, we show that, in a model- independent approach this could only be achieved in a thin sliver of the parameter space. However, with additional theoretical input the hypothesis about the thermal freeze-out as the dominant mechanism for generating dark matter canmore » potentially be verified. We illustrate this with two examples: an effective field theory of dark matter with a vector messenger and a higgsino or wino dark matter within the MSSM.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Chian-Shu; Department of Physics, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu, Taiwan, 30010 R.O.C.; Institute of Physics, Academia Sinica, 128 Sec. 2,Academia Rd., Nangang, Taipei, Taiwan, 11529 R.O.C.
2016-01-07
The halo dark matter (DM) can be captured by the Sun if its final velocity after the collision with a nucleus in the Sun is less than the escape velocity. We consider a selfinteracting dark matter (SIDM) model where U(1) gauge symmetry is introduced to account for the DM self-interaction. Such a model naturally leads to isospin violating DM-nucleon interaction, although isospin symmetric interaction is still allowed as a special case. We present the IceCube-PINGU 2σ sensitivity to the parameter range of the above model with 5 years of search for neutrino signature from DM annihilation in the Sun. Thismore » indirect detection complements the direct detection by probing those SIDM parameter ranges which are either the region for very small m{sub χ} or the region opened up due to isospin violations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Chian-Shu; Lin, Guey-Lin; Lin, Yen-Hsun, E-mail: chianshu@gmail.com, E-mail: glin@cc.nctu.edu.tw, E-mail: chris.py99g@g2.nctu.edu.tw
2016-01-01
The halo dark matter (DM) can be captured by the Sun if its final velocity after the collision with a nucleus in the Sun is less than the escape velocity. We consider a selfinteracting dark matter (SIDM) model where U(1) gauge symmetry is introduced to account for the DM self-interaction. Such a model naturally leads to isospin violating DM-nucleon interaction, although isospin symmetric interaction is still allowed as a special case. We present the IceCube-PINGU 2σ sensitivity to the parameter range of the above model with 5 years of search for neutrino signature from DM annihilation in the Sun. Thismore » indirect detection complements the direct detection by probing those SIDM parameter ranges which are either the region for very small m{sub χ} or the region opened up due to isospin violations.« less
Indirect detection of dark matter with γ rays.
Funk, Stefan
2015-10-06
The details of what constitutes the majority of the mass that makes up dark matter in the Universe remains one of the prime puzzles of cosmology and particle physics today-80 y after the first observational indications. Today, it is widely accepted that dark matter exists and that it is very likely composed of elementary particles, which are weakly interacting and massive [weakly interacting massive particles (WIMPs)]. As important as dark matter is in our understanding of cosmology, the detection of these particles has thus far been elusive. Their primary properties such as mass and interaction cross sections are still unknown. Indirect detection searches for the products of WIMP annihilation or decay. This is generally done through observations of γ-ray photons or cosmic rays. Instruments such as the Fermi large-area telescope, high-energy stereoscopic system, major atmospheric gamma-ray imaging Cherenkov, and very energetic radiation imaging telescope array, combined with the future Cherenkov telescope array, will provide important complementarity to other search techniques. Given the expected sensitivities of all search techniques, we are at a stage where the WIMP scenario is facing stringent tests, and it can be expected that WIMPs will be either be detected or the scenario will be so severely constrained that it will have to be rethought. In this sense, we are on the threshold of discovery. In this article, I will give a general overview of the current status and future expectations for indirect searches of dark matter (WIMP) particles.
Indirect detection of dark matter with γ rays
Funk, Stefan
2015-01-01
The details of what constitutes the majority of the mass that makes up dark matter in the Universe remains one of the prime puzzles of cosmology and particle physics today—80 y after the first observational indications. Today, it is widely accepted that dark matter exists and that it is very likely composed of elementary particles, which are weakly interacting and massive [weakly interacting massive particles (WIMPs)]. As important as dark matter is in our understanding of cosmology, the detection of these particles has thus far been elusive. Their primary properties such as mass and interaction cross sections are still unknown. Indirect detection searches for the products of WIMP annihilation or decay. This is generally done through observations of γ-ray photons or cosmic rays. Instruments such as the Fermi large-area telescope, high-energy stereoscopic system, major atmospheric gamma-ray imaging Cherenkov, and very energetic radiation imaging telescope array, combined with the future Cherenkov telescope array, will provide important complementarity to other search techniques. Given the expected sensitivities of all search techniques, we are at a stage where the WIMP scenario is facing stringent tests, and it can be expected that WIMPs will be either be detected or the scenario will be so severely constrained that it will have to be rethought. In this sense, we are on the threshold of discovery. In this article, I will give a general overview of the current status and future expectations for indirect searches of dark matter (WIMP) particles. PMID:24821791
Fernández, Pilar; Gabaldón, José Antonio; Periago, Mª Jesús
2017-12-01
Alicyclobacillus acidoterrestris is a thermotolerant bacterium able to grow in fruit juices and drinks, as the spoilage by Alicyclobacillus in the final product does not product any gas, but leads to a "medicine flavor" due to the formation of guaicol. Also, its detection is a challenge for the quality control departments, because it takes several days to get the results of traditional microbiology methods. This study aimed at developing a more accurate electrical impedance technique for the detection of A. acidoterrestris in concentrated apple juice. Samples of apple juice were inoculated with A. acidoterrestris spores isolated from a peach and grape juice. For the spore germination, several heat-shock treatments were tested (80 °C/10 min, 70 °C/20 min and 60 °C/30 min). Direct and indirect electrical impedance was applied to detect and quantify the microorganism in the inoculated apple juice, using BAT broth and Bimedia 002A (pH 4). The 80 °C/10 min treatment was selected for spore activation. The valid electrical impedance technique was the indirect method in BAT broth, which measured the changes in the impedance through the formation of CO 2 . In addition, a positive correlation (r = 0.98, R 2 = 0.97) was observed between the classical microbiology (BAM agar) and the indirect impedance method. Copyright © 2017 Elsevier Ltd. All rights reserved.
Didactic satellite based on Android platform for space operation demonstration and development
NASA Astrophysics Data System (ADS)
Ben Bahri, Omar; Besbes, Kamel
2018-03-01
Space technology plays a pivotal role in society development. It offers new methods for telemetry, monitoring and control. However, this sector requires training, research and skills development but the lack of instruments, materials and budgets affects the ambiguity to understand satellite technology. The objective of this paper is to describe a demonstration prototype of a smart phone device for space operations study. Therefore, the first task was carried out to give a demonstration for spatial imagery and attitude determination missions through a wireless communication. The smart phone's Bluetooth was used to achieve this goal inclusive of a new method to enable real time transmission. In addition, an algorithm around a quaternion based Kalman filter was included in order to detect the reliability of the prototype's orientation. The second task was carried out to provide a demonstration for the attitude control mission using the smart phone's orientation sensor, including a new method for an autonomous guided mode. As a result, the acquisition platform showed real time measurement with good accuracy for orientation detection and image transmission. In addition, the prototype kept the balance during the demonstration based on the attitude control method.
Indirect detection of Particle Dark Matter with gamma rays - status and perspectives
NASA Astrophysics Data System (ADS)
Conrad, Jan
2014-03-01
In this contribution I review the present status and discuss some prospects for indirect detection of dark matter with gamma rays. Thanks mainly to the Fermi Large Area Telescope (Fermi-LAT), searches in gamma-rays have reached sensitivities that allow to probe the most interesting parameter space of the weakly interacting massive particles (WIMP) paradigm. This gain in sensitivity is naturally accompanied by a number of detection claims or indications. At WIMP masses above roughly a TeV current Imaging Air Cherenkov Telescopes (HESS, VERITAS, MAGIC) become more sensitive than the Fermi-LAT, the most promising recent development being the first light for the second phase HESS II telescope with significantly lower energy threshold. Predictions for the next generation air Cherenkov telescope, Cherenkov Telescope Array (CTA), together with forecasts on future Fermi-LAT constraints arrive at the exciting possibility that the cosmological benchmark cross-section could be probed from masses of a few GeV to a few TeV. Consequently, non-detection would pose a challenge to the WIMP paradigm, but the reached sensitivities also imply that-optimistically-a detection within the next decade is in the cards. Time allowing, I will comment on complementarity between the different approaches to WIMP detection.
Hand-held spectrophotometer design for textile fabrics
NASA Astrophysics Data System (ADS)
Böcekçi, Veysel Gökhan; Yıldız, Kazım
2017-09-01
In this study, a hand-held spectrophotometer was designed by taking advantage of the developments in modern optoelectronic technology. Spectrophotometer devices are used to determine the color information from the optic properties of the materials. As an alternative to a desktop spectrophotometer device we have implemented, it is the first prototype, low cost and portable. The prototype model designed for the textile industry can detect the color tone of any fabric. The prototype model consists of optic sensor, processor, display floors. According to the color applied on the optic sensor, it produces special frequency information on its output at that color value. In Arduino type processor, the frequency information is evaluated by the program we have written and the color tone information between 0-255 ton is decided and displayed on the screen.
A modular approach to detection and identification of defects in rough lumber
Sang Mook Lee; A. Lynn Abbott; Daniel L. Schmoldt
2001-01-01
This paper describes a prototype scanning system that can automatically identify several important defects on rough hardwood lumber. The scanning system utilizes 3 laser sources and an embedded-processor camera to capture and analyze profile and gray-scale images. The modular approach combines the detection of wane (the curved sides of a board, possibly containing...
Antonuk, Larry E.; Zhao, Qihua; El-Mohri, Youcef; Du, Hong; Wang, Yi; Street, Robert A.; Ho, Jackson; Weisfield, Richard; Yao, William
2009-01-01
Active matrix flat-panel imager (AMFPI) technology is being employed for an increasing variety of imaging applications. An important element in the adoption of this technology has been significant ongoing improvements in optical signal collection achieved through innovations in indirect detection array pixel design. Such improvements have a particularly beneficial effect on performance in applications involving low exposures and∕or high spatial frequencies, where detective quantum efficiency is strongly reduced due to the relatively high level of additive electronic noise compared to signal levels of AMFPI devices. In this article, an examination of various signal properties, as determined through measurements and calculations related to novel array designs, is reported in the context of the evolution of AMFPI pixel design. For these studies, dark, optical, and radiation signal measurements were performed on prototype imagers incorporating a variety of increasingly sophisticated array designs, with pixel pitches ranging from 75 to 127 μm. For each design, detailed measurements of fundamental pixel-level properties conducted under radiographic and fluoroscopic operating conditions are reported and the results are compared. A series of 127 μm pitch arrays employing discrete photodiodes culminated in a novel design providing an optical fill factor of ∼80% (thereby assuring improved x-ray sensitivity), and demonstrating low dark current, very low charge trapping and charge release, and a large range of linear signal response. In two of the designs having 75 and 90 μm pitches, a novel continuous photodiode structure was found to provide fill factors that approach the theoretical maximum of 100%. Both sets of novel designs achieved large fill factors by employing architectures in which some, or all of the photodiode structure was elevated above the plane of the pixel addressing transistor. Generally, enhancement of the fill factor in either discrete or continuous photodiode arrays was observed to result in no degradation in MTF due to charge sharing between pixels. While the continuous designs exhibited relatively high levels of charge trapping and release, as well as shorter ranges of linearity, it is possible that these behaviors can be addressed through further refinements to pixel design. Both the continuous and the most recent discrete photodiode designs accommodate more sophisticated pixel circuitry than is present on conventional AMFPIs – such as a pixel clamp circuit, which is demonstrated to limit signal saturation under conditions corresponding to high exposures. It is anticipated that photodiode structures such as the ones reported in this study will enable the development of even more complex pixel circuitry, such as pixel-level amplifiers, that will lead to further significant improvements in imager performance. PMID:19673228
Prototype of microbolometer thermal infrared camera for forest fire detection from space
NASA Astrophysics Data System (ADS)
Guerin, Francois; Dantes, Didier; Bouzou, Nathalie; Chorier, Philippe; Bouchardy, Anne-Marie; Rollin, Joël.
2017-11-01
The contribution of the thermal infrared (TIR) camera to the Earth observation FUEGO mission is to participate; to discriminate the clouds and smoke; to detect the false alarms of forest fires; to monitor the forest fires. Consequently, the camera needs a large dynamic range of detectable radiances. A small volume, low mass and power are required by the small FUEGO payload. These specifications can be attractive for other similar missions.
2013-09-30
performance of algorithms detecting dives, strokes , clicks, respiration and gait changes. (ii) Calibration errors: Size and power constraints in...acceptance parameters used to detect and classify events. For example, swim stroke detection requires parameters defining the minimum magnitude and the min...and max duration of a stroke . Species dependent parameters can be selected from existing DTAG data but other parameters depend on the size of the
Using Policy-Capturing to Measure Attitudes in Organizational Diagnosis.
ERIC Educational Resources Information Center
Madden, Joseph M.
1981-01-01
Discusses an indirect method of attitude measurement, policy-capturing, that can be applied on an individual basis. In three experiments this method detected prejudicial attitudes toward females not detected with traditional methods. Can be used as a self-improvement diagnostic tool for developing awareness of behavior influences. (JAC)
Dark matter in dwarf spheroidal galaxies and indirect detection: a review
NASA Astrophysics Data System (ADS)
Strigari, Louis E.
2018-05-01
Indirect dark matter searches targeting dwarf spheroidal galaxies (dSphs) have matured rapidly during the past decade. This has been because of the substantial increase in kinematic data sets from the dSphs, the new dSphs that have been discovered, and the operation of the Fermi-LAT and many ground-based gamma-ray experiments. Here we review the analysis methods that have been used to determine the dSph dark matter distributions, in particular the ‘J-factors’, comparing and contrasting them, and detailing the underlying systematics that still affect the analysis. We discuss prospects for improving measurements of dark matter distributions, and how these interplay with future indirect dark matter searches.
Dark matter in dwarf spheroidal galaxies and indirect detection: a review.
Strigari, Louis E
2018-05-01
Indirect dark matter searches targeting dwarf spheroidal galaxies (dSphs) have matured rapidly during the past decade. This has been because of the substantial increase in kinematic data sets from the dSphs, the new dSphs that have been discovered, and the operation of the Fermi-LAT and many ground-based gamma-ray experiments. Here we review the analysis methods that have been used to determine the dSph dark matter distributions, in particular the 'J-factors', comparing and contrasting them, and detailing the underlying systematics that still affect the analysis. We discuss prospects for improving measurements of dark matter distributions, and how these interplay with future indirect dark matter searches.
Railroad infrastructure trespass detection performance guidelines
DOT National Transportation Integrated Search
2011-01-01
The U.S. Department of Transportations John A. Volpe National Transportation Systems Center, under the direction of the Federal Railroad Administration, conducted a 3-year demonstration of an automated prototype railroad infrastructure security sy...
Automatic multi-banking of memory for microprocessors
NASA Technical Reports Server (NTRS)
Wiker, G. A. (Inventor)
1984-01-01
A microprocessor system is provided with added memories to expand its address spaces beyond its address word length capacity by using indirect addressing instructions of a type having a detectable operations code and dedicating designated address spaces of memory to each of the added memories, one space to a memory. By decoding each operations code of instructions read from main memory into a decoder to identify indirect addressing instructions of the specified type, and then decoding the address that follows in a decoder to determine which added memory is associated therewith, the associated added memory is selectively enabled through a unit while the main memory is disabled to permit the instruction to be executed on the location to which the effective address of the indirect address instruction points, either before the indirect address is read from main memory or afterwards, depending on how the system is arranged by a switch.
A Diabetes Self-Management Prototype in an AAL-Environment to Detect Remarkable Health States.
Schindelboeck, Denise; Praus, Friedrich; Gall, Walter
2016-01-01
Every year life span is increasing and simultaneously the proportion of people with one or more chronic diseases. This paper presents an implementation of a prototype with a decision tree to detect dangerous health conditions for Diabetes Type 1 and Diabetes Type 2. With the information we collect from Personal Health Devices and data from the Active-Assisted-Living environment, we are in the position to customize thresholds and to get individual results. With the help of a modified Glucose-Insulin Model (based on the minimal model of Stolwijk & Hardy) we predicted the future glucose concentration of the patient. We validated our model with an intention-to-treat pilot study including 8 subjects and obtained a significantly better (p < 2.2-16) result than the original model.
He-Ne and CW CO2 laser long-path systems for gas detection
NASA Technical Reports Server (NTRS)
Grant, W. B.
1986-01-01
This paper describes the design and testing of a laboratory prototype dual He-Ne laser system for the detection of methane leaks from underground pipelines and solid-waste landfill sites using differential absorption of radiation backscattered from topographic targets. A laboratory-prototype dual CW carbon dioxide laser system also using topographic backscatter is discussed, and measurement results for methanol are given. With both systems, it was observed that the time-varying differential absorption signal was useful in indicating the presence of a gas coming from a nearby source. Limitations to measurement sensitivity, especially the role of speckle and atmospheric turbulence, are described. The speckle results for hard targets are contrasted with those from atmospheric aerosols. The appendix gives appropriate laser lines and values of absorption coefficients for the hydrazine fuel gases.
Reducing tensor magnetic gradiometer data for unexploded ordnance detection
Bracken, Robert E.; Brown, Philip J.
2005-01-01
We performed a survey to demonstrate the effectiveness of a prototype tensor magnetic gradiometer system (TMGS) for detection of buried unexploded ordnance (UXO). In order to achieve a useful result, we designed a data-reduction procedure that resulted in a realistic magnetic gradient tensor and devised a simple way of viewing complicated tensor data, not only to assess the validity of the final resulting tensor, but also to preview the data at interim stages of processing. The final processed map of the surveyed area clearly shows a sharp anomaly that peaks almost directly over the target UXO. This map agrees well with a modeled map derived from dipolar sources near the known target locations. From this agreement, it can be deduced that the reduction process is valid, making the prototype TMGS a foundation for development of future systems and processes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dzenitis, J. M.; Haigh, P.
This was a collaborative effort between The Regents of the University of California, Lawrence Livermore National Laboratory (LLNL), and GE Ion Track, Inc. (GEIT) to develop a commercial prototype of the Autonomous Pathogen Detection System (APDS), an instrument that monitors the air for all three biological threat agents (bacteria, viruses and toxins). This was originally a one year CRADA project, with the cost of the work at LLNL being funded by the Department of Homeland Security's Office of National Laboratories. The original project consisted of five major tasks and deliverables. The CRADA was then amended, converting the CRADA from amore » programmatically funded CRADA to a funds-in CRADA, extending the project for an additional 14 months, and adding four new tasks and deliverable to the project.« less
NASA Astrophysics Data System (ADS)
Paolozzi, L.; Bandi, Y.; Benoit, M.; Cardarelli, R.; Débieux, S.; Forshaw, D.; Hayakawa, D.; Iacobucci, G.; Kaynak, M.; Miucci, A.; Nessi, M.; Ratib, O.; Ripiccini, E.; Rücker, H.; Valerio, P.; Weber, M.
2018-04-01
The TT-PET collaboration is developing a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on state-of-the-art SiGe BiCMOS technology. The first ASIC prototype for the TT-PET was produced and tested in the laboratory and with minimum ionizing particles. The electronics exhibit an equivalent noise charge below 600 e‑ RMS and a pulse rise time of less than 2 ns , in accordance with the simulations. The pixels with a capacitance of 0.8 pF were measured to have a detection efficiency greater than 99% and, although in the absence of the post-processing, a time resolution of approximately 200 ps .
Compact silicon diffractive sensor: design, fabrication, and prototype.
Maikisch, Jonathan S; Gaylord, Thomas K
2012-07-01
An in-plane constant-efficiency variable-diffraction-angle grating and an in-plane high-angular-selectivity grating are combined to enable a new compact silicon diffractive sensor. This sensor is fabricated in silicon-on-insulator and uses telecommunications wavelengths. A single sensor element has a micron-scale device size and uses intensity-based (as opposed to spectral-based) detection for increased integrability. In-plane diffraction gratings provide an intrinsic splitting mechanism to enable a two-dimensional sensor array. Detection of the relative values of diffracted and transmitted intensities is independent of attenuation and is thus robust. The sensor prototype measures refractive index changes of 10(-4). Simulations indicate that this sensor configuration may be capable of measuring refractive index changes three or four orders of magnitude smaller. The characteristics of this sensor type make it promising for lab-on-a-chip applications.
The Development of the Spanish Fireball Network Using a New All-Sky CCD System
NASA Astrophysics Data System (ADS)
Trigo-Rodríguez, J. M.; Castro-Tirado, A. J.; Llorca, J.; Fabregat, J.; Martínez, V. J.; Reglero, V.; Jelínek, M.; Kubánek, P.; Mateo, T.; Postigo, A. De Ugarte
2004-12-01
We have developed an all-sky charge coupled devices (CCD) automatic system for detecting meteors and fireballs that will be operative in four stations in Spain during 2005. The cameras were developed following the BOOTES-1 prototype installed at the El Arenosillo Observatory in 2002, which is based on a CCD detector of 4096 × 4096 pixels with a fish-eye lens that provides an all-sky image with enough resolution to make accurate astrometric measurements. Since late 2004, a couple of cameras at two of the four stations operate for 30 s in alternate exposures, allowing 100% time coverage. The stellar limiting magnitude of the images is +10 in the zenith, and +8 below ~ 65° of zenithal angle. As a result, the images provide enough comparison stars to make astrometric measurements of faint meteors and fireballs with an accuracy of ~ 2°arcminutes. Using this prototype, four automatic all-sky CCD stations have been developed, two in Andalusia and two in the Valencian Community, to start full operation of the Spanish Fireball Network. In addition to all-sky coverage, we are developing a fireball spectroscopy program using medium field lenses with additional CCD cameras. Here we present the first images obtained from the El Arenosillo and La Mayora stations in Andalusia during their first months of activity. The detection of the Jan 27, 2003 superbolide of ± 17 ± 1 absolute magnitude that overflew Algeria and Morocco is an example of the detection capability of our prototype.
The Large Synoptic Survey Telescope as a Near-Earth Object discovery machine
NASA Astrophysics Data System (ADS)
Jones, R. Lynne; Slater, Colin T.; Moeyens, Joachim; Allen, Lori; Axelrod, Tim; Cook, Kem; Ivezić, Željko; Jurić, Mario; Myers, Jonathan; Petry, Catherine E.
2018-03-01
Using the most recent prototypes, design, and as-built system information, we test and quantify the capability of the Large Synoptic Survey Telescope (LSST) to discover Potentially Hazardous Asteroids (PHAs) and Near-Earth Objects (NEOs). We empirically estimate an expected upper limit to the false detection rate in LSST image differencing, using measurements on DECam data and prototype LSST software and find it to be about 450 deg-2. We show that this rate is already tractable with current prototype of the LSST Moving Object Processing System (MOPS) by processing a 30-day simulation consistent with measured false detection rates. We proceed to evaluate the performance of the LSST baseline survey strategy for PHAs and NEOs using a high-fidelity simulated survey pointing history. We find that LSST alone, using its baseline survey strategy, will detect 66% of the PHA and 61% of the NEO population objects brighter than H = 22 , with the uncertainty in the estimate of ± 5 percentage points. By generating and examining variations on the baseline survey strategy, we show it is possible to further improve the discovery yields. In particular, we find that extending the LSST survey by two additional years and doubling the MOPS search window increases the completeness for PHAs to 86% (including those discovered by contemporaneous surveys) without jeopardizing other LSST science goals (77% for NEOs). This equates to reducing the undiscovered population of PHAs by additional 26% (15% for NEOs), relative to the baseline survey.
Sorbello, Alfred; Ripple, Anna; Tonning, Joseph; Munoz, Monica; Hasan, Rashedul; Ly, Thomas; Francis, Henry; Bodenreider, Olivier
2017-03-22
We seek to develop a prototype software analytical tool to augment FDA regulatory reviewers' capacity to harness scientific literature reports in PubMed/MEDLINE for pharmacovigilance and adverse drug event (ADE) safety signal detection. We also aim to gather feedback through usability testing to assess design, performance, and user satisfaction with the tool. A prototype, open source, web-based, software analytical tool generated statistical disproportionality data mining signal scores and dynamic visual analytics for ADE safety signal detection and management. We leveraged Medical Subject Heading (MeSH) indexing terms assigned to published citations in PubMed/MEDLINE to generate candidate drug-adverse event pairs for quantitative data mining. Six FDA regulatory reviewers participated in usability testing by employing the tool as part of their ongoing real-life pharmacovigilance activities to provide subjective feedback on its practical impact, added value, and fitness for use. All usability test participants cited the tool's ease of learning, ease of use, and generation of quantitative ADE safety signals, some of which corresponded to known established adverse drug reactions. Potential concerns included the comparability of the tool's automated literature search relative to a manual 'all fields' PubMed search, missing drugs and adverse event terms, interpretation of signal scores, and integration with existing computer-based analytical tools. Usability testing demonstrated that this novel tool can automate the detection of ADE safety signals from published literature reports. Various mitigation strategies are described to foster improvements in design, productivity, and end user satisfaction.
Cnops, Lieselotte; Van den Eede, Peter; Pettitt, James; Heyndrickx, Leo; De Smet, Birgit; Coppens, Sandra; Andries, Ilse; Pattery, Theresa; Van Hove, Luc; Meersseman, Geert; Van Den Herrewegen, Sari; Vergauwe, Nicolas; Thijs, Rein; Jahrling, Peter B; Nauwelaers, David; Ariën, Kevin K
2016-10-15
The 2013-2016 Ebola epidemic in West Africa resulted in accelerated development of rapid diagnostic tests for emergency outbreak preparedness. We describe the development and evaluation of the Idylla™ prototype Ebola virus test, a fully automated sample-to-result molecular diagnostic test for rapid detection of Zaire ebolavirus (EBOV) and Sudan ebolavirus (SUDV). The Idylla™ prototype Ebola virus test can simultaneously detect EBOV and SUDV in 200 µL of whole blood. The sample is directly added to a disposable cartridge containing all reagents for sample preparation, RNA extraction, and amplification by reverse-transcription polymerase chain reaction analysis. The performance was evaluated with a variety of sample types, including synthetic constructs and whole blood samples from healthy volunteers spiked with viral RNA, inactivated virus, and infectious virus. The 95% limits of detection for EBOV and SUDV were 465 plaque-forming units (PFU)/mL (1010 copies/mL) and 324 PFU/mL (8204 copies/mL), respectively. In silico and in vitro analyses demonstrated 100% correct reactivity for EBOV and SUDV and no cross-reactivity with relevant pathogens. The diagnostic sensitivity was 97.4% (for EBOV) and 91.7% (for SUDV), the specificity was 100%, and the diagnostic accuracy was 95.9%. The Idylla™ prototype Ebola virus test is a fast, safe, easy-to-use, and near-patient test that meets the performance criteria to detect EBOV in patients with suspected Ebola. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
Walraph, J; Zoche-Golob, V; Weber, J; Freick, M
2018-06-01
In cattle, indirect enzyme-linked immunosorbent assay (ELISA) tests are commonly used in serological routine diagnostics. In a longitudinal study design, changes in relative optical density (OD) from drying-off until week 11 after calving were analyzed in blood and milk samples from pluriparous dairy cows (n=21) using a commercial indirect anti-C. burnetii ELISA test. In a second part of this study, changes over time were evaluated in blood and milk samples of 11 of these cows in an indirect ELISA detecting anti-Bovine viral diarrhea virus (BVDV) antibodies. Regarding the cows which were still in the herd at the time of calving, blood serological qualitative changes from positive to negative or indeterminate were demonstrated in 7/20 cows (35%) for the anti-C. burnetii indirect ELISA and in 2/10 cows (20%) for the anti-BVDV indirect ELISA, respectively, during the period from 14days ante partum to calving. Relative OD in the anti-C. burnetii and the anti-BVDV indirect ELISA tests followed basically similar courses over time. In blood serum, relative OD initially increased after drying-off, before a drop around calving was observed. After the colostrum period, relative OD in blood serum showed an increase until week 11 of lactation. In colostrum samples, relative OD levels were higher than in milk samples obtained one day before drying-off. After parturition, relative OD in milk decreased until week 6 of lactation in the anti-C. burnetii indirect ELISA and until week 11 in the anti-BVDV indirect ELISA, respectively. In conclusion, blood serological investigations in periparturient dairy cows using indirect ELISA kits should be avoided. Copyright © 2018 Elsevier Ltd. All rights reserved.
2015-01-01
Background The Internet has greatly enhanced health care, helping patients stay up-to-date on medical issues and general knowledge. Many cancer patients use the Internet for cancer diagnosis and related information. Recently, cloud computing has emerged as a new way of delivering health services but currently, there is no generic and fully automated cloud-based self-management intervention for breast cancer patients, as practical guidelines are lacking. Objective We investigated the prevalence and predictors of cloud use for medical diagnosis among women with breast cancer to gain insight into meaningful usage parameters to evaluate the use of generic, fully automated cloud-based self-intervention, by assessing how breast cancer survivors use a generic self-management model. The goal of this study was implemented and evaluated with a new prototype called “CIMIDx”, based on representative association rules that support the diagnosis of medical images (mammograms). Methods The proposed Cloud-Based System Support Intelligent Medical Image Diagnosis (CIMIDx) prototype includes two modules. The first is the design and development of the CIMIDx training and test cloud services. Deployed in the cloud, the prototype can be used for diagnosis and screening mammography by assessing the cancers detected, tumor sizes, histology, and stage of classification accuracy. To analyze the prototype’s classification accuracy, we conducted an experiment with data provided by clients. Second, by monitoring cloud server requests, the CIMIDx usage statistics were recorded for the cloud-based self-intervention groups. We conducted an evaluation of the CIMIDx cloud service usage, in which browsing functionalities were evaluated from the end-user’s perspective. Results We performed several experiments to validate the CIMIDx prototype for breast health issues. The first set of experiments evaluated the diagnostic performance of the CIMIDx framework. We collected medical information from 150 breast cancer survivors from hospitals and health centers. The CIMIDx prototype achieved high sensitivity of up to 99.29%, and accuracy of up to 98%. The second set of experiments evaluated CIMIDx use for breast health issues, using t tests and Pearson chi-square tests to assess differences, and binary logistic regression to estimate the odds ratio (OR) for the predictors’ use of CIMIDx. For the prototype usage statistics for the same 150 breast cancer survivors, we interviewed 114 (76.0%), through self-report questionnaires from CIMIDx blogs. The frequency of log-ins/person ranged from 0 to 30, total duration/person from 0 to 1500 minutes (25 hours). The 114 participants continued logging in to all phases, resulting in an intervention adherence rate of 44.3% (95% CI 33.2-55.9). The overall performance of the prototype for the good category, reported usefulness of the prototype (P=.77), overall satisfaction of the prototype (P=.31), ease of navigation (P=.89), user friendliness evaluation (P=.31), and overall satisfaction (P=.31). Positive evaluations given by 100 participants via a Web-based questionnaire supported our hypothesis. Conclusions The present study shows that women felt favorably about the use of a generic fully automated cloud-based self- management prototype. The study also demonstrated that the CIMIDx prototype resulted in the detection of more cancers in screening and diagnosing patients, with an increased accuracy rate. PMID:25830608
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rolison, L; Samant, S; Baciak, J
Purpose: To develop a Monte Carlo N-Particle (MCNP) model for the validation of a prototype backscatter x-ray (BSX) imager, and optimization of BSX technology for medical applications, including selective object-plane imaging. Methods: BSX is an emerging technology that represents an alternative to conventional computed tomography (CT) and projective digital radiography (DR). It employs detectors located on the same side as the incident x-ray source, making use of backscatter and avoiding ring geometry to enclose the imaging object. Current BSX imagers suffer from low spatial resolution. A MCNP model was designed to replicate a BSX prototype used for flaw detection inmore » industrial materials. This prototype consisted of a 1.5mm diameter 60kVp pencil beam surrounded by a ring of four 5.0cm diameter NaI scintillation detectors. The imaging phantom consisted of a 2.9cm thick aluminum plate with five 0.6cm diameter holes drilled halfway. The experimental image was created using a raster scanning motion (in 1.5mm increments). Results: A qualitative comparison between the physical and simulated images showed very good agreement with 1.5mm spatial resolution in plane perpendicular to incident x-ray beam. The MCNP model developed the concept of radiography by selective plane detection (RSPD) for BSX, whereby specific object planes can be imaged by varying kVp. 10keV increments in mean x-ray energy yielded 4mm thick slice resolution in the phantom. Image resolution in the MCNP model can be further increased by increasing the number of detectors, and decreasing raster step size. Conclusion: MCNP modelling was used to validate a prototype BSX imager and introduce the RSPD concept, allowing for selective object-plane imaging. There was very good visual agreement between the experimental and MCNP imaging. Beyond optimizing system parameters for the existing prototype, new geometries can be investigated for volumetric image acquisition in medical applications. This material is based upon work supported under an Integrated University Program Graduate Fellowship sponsored by the Department of Energy Office of Nuclear Energy.« less
How good are indirect tests at detecting recombination in human mtDNA?
White, Daniel James; Bryant, David; Gemmell, Neil John
2013-07-08
Empirical proof of human mitochondrial DNA (mtDNA) recombination in somatic tissues was obtained in 2004; however, a lack of irrefutable evidence exists for recombination in human mtDNA at the population level. Our inability to demonstrate convincingly a signal of recombination in population data sets of human mtDNA sequence may be due, in part, to the ineffectiveness of current indirect tests. Previously, we tested some well-established indirect tests of recombination (linkage disequilibrium vs. distance using D' and r(2), Homoplasy Test, Pairwise Homoplasy Index, Neighborhood Similarity Score, and Max χ(2)) on sequence data derived from the only empirically confirmed case of human mtDNA recombination thus far and demonstrated that some methods were unable to detect recombination. Here, we assess the performance of these six well-established tests and explore what characteristics specific to human mtDNA sequence may affect their efficacy by simulating sequence under various parameters with levels of recombination (ρ) that vary around an empirically derived estimate for human mtDNA (population parameter ρ = 5.492). No test performed infallibly under any of our scenarios, and error rates varied across tests, whereas detection rates increased substantially with ρ values > 5.492. Under a model of evolution that incorporates parameters specific to human mtDNA, including rate heterogeneity, population expansion, and ρ = 5.492, successful detection rates are limited to a range of 7-70% across tests with an acceptable level of false-positive results: the neighborhood similarity score incompatibility test performed best overall under these parameters. Population growth seems to have the greatest impact on recombination detection probabilities across all models tested, likely due to its impact on sequence diversity. The implications of our findings on our current understanding of mtDNA recombination in humans are discussed.
How Good Are Indirect Tests at Detecting Recombination in Human mtDNA?
White, Daniel James; Bryant, David; Gemmell, Neil John
2013-01-01
Empirical proof of human mitochondrial DNA (mtDNA) recombination in somatic tissues was obtained in 2004; however, a lack of irrefutable evidence exists for recombination in human mtDNA at the population level. Our inability to demonstrate convincingly a signal of recombination in population data sets of human mtDNA sequence may be due, in part, to the ineffectiveness of current indirect tests. Previously, we tested some well-established indirect tests of recombination (linkage disequilibrium vs. distance using D′ and r2, Homoplasy Test, Pairwise Homoplasy Index, Neighborhood Similarity Score, and Max χ2) on sequence data derived from the only empirically confirmed case of human mtDNA recombination thus far and demonstrated that some methods were unable to detect recombination. Here, we assess the performance of these six well-established tests and explore what characteristics specific to human mtDNA sequence may affect their efficacy by simulating sequence under various parameters with levels of recombination (ρ) that vary around an empirically derived estimate for human mtDNA (population parameter ρ = 5.492). No test performed infallibly under any of our scenarios, and error rates varied across tests, whereas detection rates increased substantially with ρ values > 5.492. Under a model of evolution that incorporates parameters specific to human mtDNA, including rate heterogeneity, population expansion, and ρ = 5.492, successful detection rates are limited to a range of 7−70% across tests with an acceptable level of false-positive results: the neighborhood similarity score incompatibility test performed best overall under these parameters. Population growth seems to have the greatest impact on recombination detection probabilities across all models tested, likely due to its impact on sequence diversity. The implications of our findings on our current understanding of mtDNA recombination in humans are discussed. PMID:23665874
Bu, Ri-E; Wang, Jin-Liang; Wu, Jin-Hua; Xilin, Gao-Wa; Chen, Jin-Long; Wang, Hua
2017-03-01
The aim of this study was to establish a rapid and accurate method for the detection of the Streptococcus agalactiae antibody (SA-Ab) to determine the presence of the bovine mastitis (BM)-causative pathogen. The multi-subunit fusion protein rSip-Pgk-FbsA was prokaryotically expressed and purified. The triple activities of the membrane surface-associated proteins Sip, phosphoglycerate kinase (Pgk), and fibronectin (FbsA) were used as the diagnostic antigens to establish an indirect enzyme-linked immunosorbent assay (ELISA) method for the detection of SA-Ab in BM. The optimal antigen coating concentration was 2 μg/mL, the optimal serum dilution was 1:160, and the optimal dilution of the enzyme-labeled secondary antibody was 1:6000. The sensitivity, specificity, and repeatability tests showed that the method established in this study had no cross-reaction with antibodies to Streptococcus pyogenes, Escherichia coli, Staphylococcus aureus, and Staphylococcus epidermidis in the sera. The results of the sensitivity test showed that a positive result could be obtained even if the serum dilution reached 1:12,800, indicating the high sensitivity and good repeatability of the method. The positive coincidence rate of this method was 98.6%, which is higher than that of previous tests established with the Sip or Pgk mono-antigen fusion protein, respectively, demonstrating the relatively higher sensitivity of this newly established method. The detection rate for 389 clinical samples was 46.53%. The indirect ELISA method established in this study could provide a more accurate and reliable serological method for the rapid detection of S. agalactiae in cases of BM.
USDA-ARS?s Scientific Manuscript database
An indirect ELISA was developed using baculovirus expressed N1 protein from the A/chicken/Indonesia/7/2003 (H5N1) virus. The specificity of the assay was tested with a panel of chicken antisera raised against N1 to N9 virus subtypes. The N1-ELISA was specific for the detection of N1 antibodies in ...
Myoelectric hand prosthesis force control through servo motor current feedback.
Sono, Tálita Saemi Payossim; Menegaldo, Luciano Luporini
2009-10-01
This paper presents the prehension force closed-loop control design of a mechanical finger commanded by electromyographic signal (EMG) from a patient's arm. The control scheme was implemented and tested in a mechanical finger prototype with three degrees of freedom and one actuator, driven by arm muscles EMG of normal volunteers. Real-time indirect estimation of prehension force was assessed by measuring the DC servo motor actuator current. A model of the plant comprising finger, motor, and grasped object was proposed. Model parameters were identified experimentally and a classical feedback phase-lead compensator was designed. The controlled mechanical finger was able to provide a more accurate prehension force modulation of a compliant object when compared to open-loop control.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ames, Andrew; Ampleford, David; Bourdon, Chris
Here, we have developed a process for indirectly coating small diameter electroformed nickel replicated optics with multilayers to increase their response at high energy (i.e. >10 keV). The ability to fabricate small diameter multilayer-coated full-shell Wolter X-ray optics with narrow bandpass opens the door to several applications within astronomy and also provides a path for cross-fertilization to other fields. We report on the characterization and evaluation of the first two prototype X-ray Wolter optics to be delivered to the Z Pulsed Power Facility at Sandia National Laboratories. The intent is to develop and field several optics as part of anmore » imaging system with targeted spectral ranges.« less
Ames, Andrew; Ampleford, David; Bourdon, Chris; ...
2017-08-29
Here, we have developed a process for indirectly coating small diameter electroformed nickel replicated optics with multilayers to increase their response at high energy (i.e. >10 keV). The ability to fabricate small diameter multilayer-coated full-shell Wolter X-ray optics with narrow bandpass opens the door to several applications within astronomy and also provides a path for cross-fertilization to other fields. We report on the characterization and evaluation of the first two prototype X-ray Wolter optics to be delivered to the Z Pulsed Power Facility at Sandia National Laboratories. The intent is to develop and field several optics as part of anmore » imaging system with targeted spectral ranges.« less
A four-dimensional primitive equation model for coupled coastal-deep ocean studies
NASA Technical Reports Server (NTRS)
Haidvogel, D. B.
1981-01-01
A prototype four dimensional continental shelf/deep ocean model is described. In its present form, the model incorporates the effects of finite amplitude topography, advective nonlinearities, and variable stratification and rotation. The model can be forced either directly by imposed atmospheric windstress and surface pressure distributions, and energetic mean currents imposed by the exterior oceanic circulation; or indirectly by initial distributions of shoreward propagation mesoscale waves and eddies. To avoid concerns over the appropriate specification of 'open' boundary conditions on the cross-shelf and seaward model boundaries, a periodic channel geometry (oriented along-coast) is used. The model employs a traditional finite difference expansion in the cross-shelf direction, and a Fourier (periodic) representation in the long-shelf coordinate.
NASA Astrophysics Data System (ADS)
Ames, A.; Ampleford, D.; Bourdon, C.; Bruni, R.; Kilaru, K.; Kozioziemski, B.; Pivovaroff, M.; Ramsey, B.; Romaine, S.; Vogel, J.; Walton, C.; Wu, M.
2017-08-01
We have developed a process for indirectly coating arbitrarily small diameter electroformed nickel replicated optics with multilayers to increase their response at high energy (i.e. >10 keV). The ability to fabricate small diameter multilayer coated full shell Wolter X-ray optics with narrow bandpass opens the door to several applications within astronomy and also provides a path for cross-fertilization to other fields. We report on the characterization and evaluation of the first two prototype X-ray Wolter optics to be delivered to the Z Pulsed Power Facility at Sandia National Laboratories. The intent is to develop and field several optics as part of an imaging system with targeted spectral ranges.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sikes, Karen; Blackburn, Julia; Grubbs, Tyler
Despite a steady record of energy efficiency improvements in residential refrigerators and freezers over recent decades, these products still account for 4% of the site energy consumption for the average U.S. household. The Oak Ridge National Laboratory (ORNL) – along with partners Sandia National Laboratories (SNL) and the University of Maryland – are pursuing further efficiency improvements in this market sector by using a novel/prototype rotating heat exchanger (RHX) based on a Sandia Cooler technology as an evaporator in a residential refrigerator-freezer. The purpose of this study is to investigate the market potential of refrigerator-freezer products equipped with RHX evaporatorsmore » in the United States, including projections of maximum annual market share and unit shipments and maximum direct and indirect job creation.« less
Zhang, Chaoting; Liu, Ying; Gao, Weijiao; Pan, Yaqi; Gao, Yunong; Shen, Jing; Xiong, Hongchao
2018-05-01
Cervical microbiota composition is associated with cervical HPV infection and CIN severity. Previous studies only assessed the total association between cervical microbiota and HPV infections or CINs, and yet no study reported the direct and indirect associations between cervical microbiota and CINs mediated by HPV infection, respectively. The aim of this study was to investigate the direct and indirect associations between microbiotas and CIN severity. Cervical microbiota of 126 women with CIN 1- (normal cytology and CIN 1) and 40 with CIN 2+ (CIN 2 and CIN 3) were analyzed using Illumina sequencing based on the 16S rRNA gene. HPV was detected using a highly sensitive PCR primer set (SPF1/GP6+). Indirect effects of Pseudomonas stutzeri, Bacteroides fragilis, Lactobacillus delbrueckii, Atopobium vaginae, and Streptococcus agalactiae mediated by HPV infection on CIN status were observed. The directions of the direct and the indirect associations between CIN status and Ps. stutzeri were opposite. The directions of the direct and the indirect associations between CIN status and A. vaginae were the same. B. fragilis, L. delbrueckii, and S. agalactiae only had indirect association with CIN status. In summary, our study provided suggestive evidence that some microbial populations could have direct or indirect effects mediated by affecting HPV infection on CIN progression. Besides HPV infection, microbial community composition possibly plays a role in cervical carcinogenesis. © 2018 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Radulescu, A.; Arend, N.; Drochner, M.; Ioffe, A.; Kemmerling, G.; Ossovyi, V.; Staringer, S.; Vehres, G.; McKinny, K.; Olechnowicz, B.; Yen, D.
2016-09-01
A new detection system based on an array of 3He tubes and innovative fast detection electronics was designed and produced by GE Reuter Stokes for the high-intensity small-angle neutron scattering diffractometer KWS-2, operated by the Jülich Centre for Neutron Science (JCNS) at the Heinz Meier-Leibnitz Zentrum (MLZ). The new detector consists of a panel array of 144 3He tubes and a new fast read-out electronics. The electronics is mounted in a closed case in the backside of the 3He tubes panel array and will operate at ambient atmosphere under cooling air stream. The new detection system is composed of eighteen 8-pack modules of 3He-tubes that work independently of one another (each unit has its own processor and electronics). Knowing beforehand the performance of one detector unit and of one single tube detector is prerequisite for tuning and maximizing the performance of the complete detection system. In this paper we present the results of the tests of the prototyped 8-pack of 3He-tubes and corresponding electronics, which have been carried out at the JCNS instruments KWS-2 (in high flux conditions) and TREFF.
Laser diode arrays for naval reconnaissance
NASA Astrophysics Data System (ADS)
Holloway, John H., Jr.; Crosby, Frank J.; Petee, Danny A.; Suiter, Harold R.; Witherspoon, Ned H.
2003-09-01
The Airborne Littoral Reconnaissance Technologies (ALRT) Project has demonstrated a nighttime operational minefield detection capability using commercial off-the-shelf high-power Laser Diode Arrays (LDAs). Historically, optical aerial detection of minefields has primarily been limited to daytime operations but LDAs promise compact and efficient lighting to allow for enhanced reconnaissance operations for future mine detection systems. When combined with high-resolution intensified imaging systems, LDAs can illuminate otherwise unseen areas. Future wavelength options will open the way for active multispectral imaging with LDAs. The Coastal Systems Station working for the Office of Naval Research on the ALRT project has designed, developed, integrated, and tested both prototype and commercial arrays from a Cessna airborne platform. Detailed test results show the ability to detect several targets of interest in a variety of background conditions. Initial testing of the prototype arrays, reported on last year, was completed and further investigations of the commercial versions were performed. Polarization-state detection studies were performed, and advantageous properties of the source-target-sensor geometry noted. Current project plans are to expand the field-of-view coverage for Naval exercises in the summer of 2003. This paper describes the test collection, data library products, array information, on-going test analysis results, and future planned testing of the LDAs.
The Principle of the Micro-Electronic Neural Bridge and a Prototype System Design.
Huang, Zong-Hao; Wang, Zhi-Gong; Lu, Xiao-Ying; Li, Wen-Yuan; Zhou, Yu-Xuan; Shen, Xiao-Yan; Zhao, Xin-Tai
2016-01-01
The micro-electronic neural bridge (MENB) aims to rebuild lost motor function of paralyzed humans by routing movement-related signals from the brain, around the damage part in the spinal cord, to the external effectors. This study focused on the prototype system design of the MENB, including the principle of the MENB, the neural signal detecting circuit and the functional electrical stimulation (FES) circuit design, and the spike detecting and sorting algorithm. In this study, we developed a novel improved amplitude threshold spike detecting method based on variable forward difference threshold for both training and bridging phase. The discrete wavelet transform (DWT), a new level feature coefficient selection method based on Lilliefors test, and the k-means clustering method based on Mahalanobis distance were used for spike sorting. A real-time online spike detecting and sorting algorithm based on DWT and Euclidean distance was also implemented for the bridging phase. Tested by the data sets available at Caltech, in the training phase, the average sensitivity, specificity, and clustering accuracies are 99.43%, 97.83%, and 95.45%, respectively. Validated by the three-fold cross-validation method, the average sensitivity, specificity, and classification accuracy are 99.43%, 97.70%, and 96.46%, respectively.
Li, Pingjing; Hu, Bin; Li, Xiaoyong
2012-07-20
In this study, a sensitive, selective and reliable analytical method by combining zirconia (ZrO₂) coated stir bar sorptive extraction (SBSE) with large volume sample stacking capillary electrophoresis-indirect ultraviolet (LVSS-CE/indirect UV) was developed for the direct analysis of chemical warfare agent degradation products of alkyl alkylphosphonic acids (AAPAs) (including ethyl methylphosphonic acid (EMPA) and pinacolyl methylphosphonate (PMPA)) and methylphosphonic acid (MPA) in environmental waters. ZrO₂ coated stir bar was prepared by adhering nanometer-sized ZrO₂ particles onto the surface of stir bar with commercial PDMS sol as adhesion agent. Due to the high affinity of ZrO₂ to the electronegative phosphonate group, ZrO₂ coated stir bars could selectively extract the strongly polar AAPAs and MPA. After systematically optimizing the extraction conditions of ZrO₂-SBSE, the analytical performance of ZrO₂-SBSE-CE/indirect UV and ZrO₂-SBSE-LVSS-CE/indirect UV was assessed. The limits of detection (LODs, at a signal-to-noise ratio of 3) obtained by ZrO₂-SBSE-CE/indirect UV were 13.4-15.9 μg/L for PMPA, EMPA and MPA. The relative standard deviations (RSDs, n=7, c=200 μg/L) of the corrected peak area for the target analytes were in the range of 6.4-8.8%. Enhancement factors (EFs) in terms of LODs were found to be from 112- to 145-fold. By combining ZrO₂ coating SBSE with LVSS as a dual preconcentration strategy, the EFs were magnified up to 1583-fold, and the LODs of ZrO₂-SBSE-LVSS-CE/indirect UV were 1.4, 1.2 and 3.1 μg/L for PMPA, EMPA, and MPA, respectively. The RSDs (n=7, c=20 μg/L) were found to be in the range of 9.0-11.8%. The developed ZrO₂-SBSE-LVSS-CE/indirect UV method has been successfully applied to the analysis of PMPA, EMPA, and MPA in different environmental water samples, and the recoveries for the spiked water samples were found to be in the range of 93.8-105.3%. Copyright © 2012 Elsevier B.V. All rights reserved.
Ross, Martin R.; Borman, Earle K.
1963-01-01
Ross, Martin R. (Connecticut State Department of Health, Hartford) and Earle K. Borman. Direct and indirect fluorescent-antibody techniques for the psittacosis-lymphogranuloma venereum-trachoma group of agents. J. Bacteriol. 85:851–858. 1963.—Direct and indirect fluorescent-antibody (FA) techniques were developed for the detection of group antigen in infected tissue cultures and the titration of group antibody in human antiserum. The growth of the agent of meningopneumonitis (MP) in mouse embryo lung cell monolayers was followed by infectivity and complement-fixing (CF) antigen titrations, and cytological examination of FA stained cultures. Although infectivity and CF antigen reached a peak at 2 days and remained constant for an additional 3 days, only cells tested 2 to 3 days after infection were suitable for FA staining with labeled anti-MP serum because of excessive artifacts in the older cultures. Fluorescein isothiocyanate-labeled rooster and guinea pig anti-MP serums and human antipsittacosis serums were titrated in direct FA and hemagglutination-inhibition (HI) tests. The rooster conjugate showed brighter staining and higher antibody titers than the guinea pig or human conjugates and was more effective in detecting minimal amounts of virus antigen. FA staining reactions with 1 and 2 units of labeled rooster serum were inhibited by unlabeled rooster serum but clear-cut inhibition with human antipsittacosis serum could not be demonstrated. The indirect FA technique was successfully used for the titration of group antibody in human serum. A comparison of the indirect FA, HI, and CF tests showed the indirect FA technique to be intermediate in sensitivity between the HI and CF tests. None of the three tests showed significant cross reactions with human serums reactive for influenza A and B; parainfluenza 1, 2, and 3; respiratory syncytial virus; Q fever; or the primary atypical pneumonia agent. PMID:14044954
Brandt, J A; Kettering, J D; Lewis, J E
1984-01-01
The complement fixation test is currently the test employed most frequently to determine the presence of antibody to human cytomegalovirus. Several other techniques have been adapted for this purpose. A comparison of cytomegalovirus antibody titers was made between the complement fixation test, a commercially available enzyme-linked immunosorbent assay, an indirect immunofluorescent technique, and a modified indirect hemagglutination test. Forty-three serum samples were tested for antibodies by each of the above procedures. The enzyme-linked immunosorbent, immunofluorescent, and indirect hemagglutination assays were in close agreement on all samples tested; the titers obtained with these methods were all equal to or greater than the complement fixation titer for 38 of the 41 samples (92.6%). Two samples were anticomplementary in the complement fixation test but gave readable results in the other tests. The complement fixation test was the least sensitive of the procedures examined. The commercial enzyme-linked immunosorbent assay system was the most practical method and offered the highest degree of sensitivity in detecting antibodies to cytomegalovirus. PMID:6321544
Metal-oxide-metal point contact junction detectors. [detection mechanism and mechanical stability
NASA Technical Reports Server (NTRS)
Baird, J.; Havemann, R. H.; Fults, R. D.
1973-01-01
The detection mechanism(s) and design of a mechanically stable metal-oxide-metal point contact junction detector are considered. A prototype for a mechanically stable device has been constructed and tested. A technique has been developed which accurately predicts microwave video detector and heterodyne mixer SIM (semiconductor-insulator-metal) diode performance from low dc frequency volt-ampere curves. The difference in contact potential between the two metals and geometrically induced rectification constitute the detection mechanisms.
Railroad infrastructure trespassing detection systems research in Pittsford, New York
DOT National Transportation Integrated Search
2006-08-01
The U.S. Department of Transportations Volpe National Transportation Systems Center, under the direction of the Federal Railroad Administration, conducted a 3-year demonstration of an automated prototype railroad infrastructure security system on ...
Urban Methane Point Sources Detected by Tiered System of Remote-sensing Observations
2015-07-10
This image captured by a prototype NASA satellite instrument at NASA California Laboratory for Atmospheric Remote Sensing CLARS shows a persistent methane hotspot central red area over Los Angeles basin.
Implementation of a General Real-Time Visual Anomaly Detection System Via Soft Computing
NASA Technical Reports Server (NTRS)
Dominguez, Jesus A.; Klinko, Steve; Ferrell, Bob; Steinrock, Todd (Technical Monitor)
2001-01-01
The intelligent visual system detects anomalies or defects in real time under normal lighting operating conditions. The application is basically a learning machine that integrates fuzzy logic (FL), artificial neural network (ANN), and generic algorithm (GA) schemes to process the image, run the learning process, and finally detect the anomalies or defects. The system acquires the image, performs segmentation to separate the object being tested from the background, preprocesses the image using fuzzy reasoning, performs the final segmentation using fuzzy reasoning techniques to retrieve regions with potential anomalies or defects, and finally retrieves them using a learning model built via ANN and GA techniques. FL provides a powerful framework for knowledge representation and overcomes uncertainty and vagueness typically found in image analysis. ANN provides learning capabilities, and GA leads to robust learning results. An application prototype currently runs on a regular PC under Windows NT, and preliminary work has been performed to build an embedded version with multiple image processors. The application prototype is being tested at the Kennedy Space Center (KSC), Florida, to visually detect anomalies along slide basket cables utilized by the astronauts to evacuate the NASA Shuttle launch pad in an emergency. The potential applications of this anomaly detection system in an open environment are quite wide. Another current, potentially viable application at NASA is in detecting anomalies of the NASA Space Shuttle Orbiter's radiator panels.
NASA Astrophysics Data System (ADS)
Pavese, F.; Szmyrka-Grzebyk, A.; Lipinski, L.; Manuszkiewicz, H.; Qiu, Ping; Zhang, Jin Tao; Lin, Peng; Li, Xing Wei
2008-02-01
Given the practical impossibility of obtaining new precision Rh-0.5at%Fe resistance thermometers in recent years, the possible re-starting of the production of such thermometers in Yunnan (China) was explored by Istituto Nazionale di Ricerca Metrologica (INRIM). Ten prototypes of the new production were made available in early 2006. The paper reports the preliminary data from the testing performed to date on these prototypes at National Institute of Metrology (NIM) and Instytut Niskich Temperatur i Badan Strukturalnych (INTiBS). Although a problem with the alloy composition was detected, the reproducibility results on thermal cycling are very encouraging. Resistance-temperature ( R- T) characteristics below 30 K, though not identical with those of similar thermometers formerly available from Tinsley and VNIIFTRI, are still suitable for accurate metrology.
NASA Astrophysics Data System (ADS)
Valencia, Juan D.; Diaz, Aaron A.; Tucker, Brian J.
2008-03-01
The increase of terrorism and its global impact has made the screening of the contents of liquid-filled containers a necessity. The ability to evaluate the contents of a container rapidly and accurately is a critical tool in maintaining global safety and security. Due to the immense quantities and large variety of containers shipped worldwide, there is a need for a technology that enables rapid and effective ways of conducting non-intrusive container inspections. Such inspections can be performed utilizing "through-transmission" or "pulse-echo" acoustic techniques, in combination with multiple frequency excitation pulses or waveforms. The challenge is combining and switching between the different acoustic techniques without distorting the excitation pulse or waveform, degrading or adding noise to the receive signal; while maintaining a portable, low-power, low-cost, and easy to use system. The Pacific Northwest National Laboratory (PNNL) has developed a methodology and prototype device focused on this challenge. The prototype relies on an advanced diplexer circuit capable of rapidly switching between both "through-transmission" and "pulse-echo" detection modes. This type of detection requires the prototype to isolate the pulsing circuitry from the receiving circuitry to prevent damage and reduce noise. The results of this work demonstrate that an advanced diplexer circuit can be effective; however, some bandwidth issues exist. This paper focuses on laboratory measurements and test results acquired with the PNNL prototype device as applied to several types of liquid-filled containers. Results of work conducted in the laboratory will be presented and future measurement platform enhancements will be discussed.
A novel electron tunneling infrared detector
NASA Technical Reports Server (NTRS)
Kenny, T. W.; Waltman, S. B.; Reynolds, J. K.; Kaiser, W. J.
1990-01-01
The pneumatic infrared detector, originally developed by Golay in the late 1940s, uses the thermal expansion of one cm(exp 3) of xenon at room temperature to detect the heat deposited by infrared radiation. This detector was limited by thermal fluctuations within a 10 Hz bandwidth, but suffered from long thermal time constants and a fragile structure. Nevertheless, it represents the most sensitive room temperature detector currently available in the long wavelength infrared (LWIR). Fabrication of this type of detector on smaller scales has been limited by the lack of a suitably sensitive transducer. Researchers designed a detector based on this principle, but which is constructed entirely from micromachined silicon, and uses a vacuum tunneling transducer to detect the expansion of the trapped gas. Because this detector is fabricated using micromachining techniques, miniaturization and integration into one and two-dimensional arrays is feasible. The extreme sensitivity of vacuum tunneling to changes in electrode separation will allow a prototype of this detector to operate in the limit of thermal fluctuations over a 10 kHz bandwidth. A calculation of the predicted response and noise of the prototype is presented with the general formalism of thermal detectors. At present, most of the components of the prototype have been fabricated and tested independently. In particular, a characterization of the micromachined electron tunneling transducer has been carried out. The measured noise in the tunnel current is within a decade of the limit imposed by shot noise, and well below the requirements for the operation of an infrared detector with the predicted sensitivity. Assembly and characterization of the prototype infrared detector will be carried out promptly.
A chronic generalized bi-directional brain-machine interface.
Rouse, A G; Stanslaski, S R; Cong, P; Jensen, R M; Afshar, P; Ullestad, D; Gupta, R; Molnar, G F; Moran, D W; Denison, T J
2011-06-01
A bi-directional neural interface (NI) system was designed and prototyped by incorporating a novel neural recording and processing subsystem into a commercial neural stimulator architecture. The NI system prototype leverages the system infrastructure from an existing neurostimulator to ensure reliable operation in a chronic implantation environment. In addition to providing predicate therapy capabilities, the device adds key elements to facilitate chronic research, such as four channels of electrocortigram/local field potential amplification and spectral analysis, a three-axis accelerometer, algorithm processing, event-based data logging, and wireless telemetry for data uploads and algorithm/configuration updates. The custom-integrated micropower sensor and interface circuits facilitate extended operation in a power-limited device. The prototype underwent significant verification testing to ensure reliability, and meets the requirements for a class CF instrument per IEC-60601 protocols. The ability of the device system to process and aid in classifying brain states was preclinically validated using an in vivo non-human primate model for brain control of a computer cursor (i.e. brain-machine interface or BMI). The primate BMI model was chosen for its ability to quantitatively measure signal decoding performance from brain activity that is similar in both amplitude and spectral content to other biomarkers used to detect disease states (e.g. Parkinson's disease). A key goal of this research prototype is to help broaden the clinical scope and acceptance of NI techniques, particularly real-time brain state detection. These techniques have the potential to be generalized beyond motor prosthesis, and are being explored for unmet needs in other neurological conditions such as movement disorders, stroke and epilepsy.
Wang, Weiping; Tang, Jianghong; Wang, Shumin; Zhou, Lei; Hu, Zhide
2007-04-27
A capillary zone electrophoresis (CZE) with indirect laser-induced fluorescence detection (ILIFD) method is described for the simultaneous determination of esculin, esculetin, isofraxidin, genistein, naringin and sophoricoside. The baseline separation was achieved within 5 min with running buffer (pH 9.4) composed of 5mM borate, 20% methanol (v/v) as organic modifier, 10(-7)M fluorescein sodium as background fluorophore and 20 kV of applied voltage at 30 degrees C of cartridge temperature. Good linearity relationships (correlation coefficients >0.9900) between the second-order derivative peak-heights (RFU) and concentrations of the analytes (mol L(-1)) were obtained. The detection limits for all analytes in second-order derivative electrophoregrams were in the range of 3.8-15 microM. The RSD data of intra-day for migration times and second-order derivative peak-height were less than 0.95 and 5.02%, respectively. This developed method was applied to the analysis of the courmin compounds in herb plants with recoveries in the range of 94.7-102.1%. In this work, although the detection sensitivity was lower than that of direct LIF, yet the method would extend the application range of LIF detection.
CRIM-TRACK: sensor system for detection of criminal chemical substances
NASA Astrophysics Data System (ADS)
Munk, Jens K.; Buus, Ole T.; Larsen, Jan; Dossi, Eleftheria; Tatlow, Sol; Lässig, Lina; Sandström, Lars; Jakobsen, Mogens H.
2015-10-01
Detection of illegal compounds requires a reliable, selective and sensitive detection device. The successful device features automated target acquisition, identification and signal processing. It is portable, fast, user friendly, sensitive, specific, and cost efficient. LEAs are in need of such technology. CRIM-TRACK is developing a sensing device based on these requirements. We engage highly skilled specialists from research institutions, industry, SMEs and LEAs and rely on a team of end users to benefit maximally from our prototypes. Currently we can detect minute quantities of drugs, explosives and precursors thereof in laboratory settings. Using colorimetric technology we have developed prototypes that employ disposable sensing chips. Ease of operation and intuitive sensor response are highly prioritized features that we implement as we gather data to feed into machine learning. With machine learning our ability to detect threat compounds amidst harmless substances improves. Different end users prefer their equipment optimized for their specific field. In an explosives-detecting scenario, the end user may prefer false positives over false negatives, while the opposite may be true in a drug-detecting scenario. Such decisions will be programmed to match user preference. Sensor output can be as detailed as the sensor allows. The user can be informed of the statistics behind the detection, identities of all detected substances, and quantities thereof. The response can also be simplified to "yes" vs. "no". The technology under development in CRIM-TRACK will provide custom officers, police and other authorities with an effective tool to control trafficking of illegal drugs and drug precursors.
Zhang, Yuyao; Ma, Xiuli; Huang, Bing; Li, Yufeng; Yu, Kexiang; Li, Jianliang; Liu, Cunxia; Han, Hongyu; Cui, Yanshun
2015-04-04
To simultaneously detect antibodies against Duck hepatitis A type 1 (DHAV-1) and type 3 (DHAV-3) viruses, we developed an indirect enzyme-linked immunosobent assay (ELISA) with bacterially expressed recombinant viral protein as antigen in Escherichia coli. We amplified the full-length VP3 gene of DHAV-1 and the full-length VP1 gene of DHAV-3 through reverse transcription-polymerase chain reaction (RT-PCR) and then cloned them into pET-32a expression vector, designated as pET-1VP3-3VP1. The fusion protein DHAV-1VP3-3VP1 expressed correctly and was subsequently used to develop an indirect ELISA assay. DHAV-1VP3-3VP1 fusion protein expressed in BL21 (DE3) cells following induction by Isopropyl-beta-D-1-thiogalactopyranoside (IPTG). The expressed protein was very antigenic and reactive to virus-specific antibodies in western blot assay. The optimal working concentration for coating antigen was 1.0 microg per well and the working concentration of serum samples was 1:200 dilution and the cut-off value that distinguished the positive from negative serum samples was OD650 > OR = 0.38. The ELISA method based on the prokaryotic expression of VP3 (DHAV-1) and VP1 proteins (DHAV-3) can be used effectively for the clinical detection antibodies against DHAV-1 and DHAV-3.
Merli, Marco; Galli, Laura; Castagna, Antonella; Salpietro, Stefania; Gianotti, Nicola; Messina, Emanuela; Poli, Andrea; Morsica, Giulia; Bagaglio, Sabrina; Cernuschi, Massimo; Bigoloni, Alba; Uberti-Foppa, Caterina; Lazzarin, Adriano; Hasson, Hamid
2016-04-01
We determined the diagnostic accuracy and optimal cut off of three indirect fibrosis biomarkers (APRI, FIB-4, Forns) compared with liver stiffness (LS) for the detection of liver cirrhosis in HIV/HCV-coinfected patients. An observational retrospective study on HIV/HCV-coinfected patients with concomitant LS measurement and APRI, FIB-4 and Forns was performed. The presence of liver cirrhosis was defined as a LS ≥13 KPa. The diagnostic accuracy and optimal cut-off values, compared with LS categorization (<13 vs ≥13 KPa), were determined by receiver operating characteristics (ROC) curves. The study sample included 646 patients. The area-under-the ROC curve (95% confidence interval) for the detection of liver cirrhosis were 0.84 (0.81-0.88), 0.87 (0.84-0.91) and 0.87 (0.84-0.90) for APRI, FIB-4 and Forns, respectively. According to the optimal cut off values for liver cirrhosis (≥0.97 for APRI, ≥2.02 for FIB-4 and ≥7.8 for Forns), 80%, 80% and 82% of subjects were correctly classified by the three indirect fibrosis biomarkers, respectively. Misclassifications were mostly due to false positive cases. The study suggests that indirect fibrosis biomarkers can help clinicians to exclude liver cirrhosis in the management of HIV/HCV co-infected patients, reducing the frequency of more expensive or invasive assessments.
Indirect Charged Particle Detection: Concepts and a Classroom Demonstration
ERIC Educational Resources Information Center
Childs, Nicholas B.; Horányi, Mihály; Collette, Andrew
2013-01-01
We describe the principles of macroscopic charged particle detection in the laboratory and their connections to concepts taught in the physics classroom. Electrostatic dust accelerator systems, capable of launching charged dust grains at hypervelocities (1-100 km/s), are a critical tool for space exploration. Dust grains in space typically have…
USDA-ARS?s Scientific Manuscript database
Streptococcus iniae is among the major pathogens of a large number of fish species cultured in fresh and marine recirculating and net pen production systems . The traditional plate culture technique to detect and identify S. iniae is time consuming and may be problematic due to phenotypic variations...
Warner, Jeremy L; Rioth, Matthew J; Mandl, Kenneth D; Mandel, Joshua C; Kreda, David A; Kohane, Isaac S; Carbone, Daniel; Oreto, Ross; Wang, Lucy; Zhu, Shilin; Yao, Heming; Alterovitz, Gil
2016-07-01
Precision cancer medicine (PCM) will require ready access to genomic data within the clinical workflow and tools to assist clinical interpretation and enable decisions. Since most electronic health record (EHR) systems do not yet provide such functionality, we developed an EHR-agnostic, clinico-genomic mobile app to demonstrate several features that will be needed for point-of-care conversations. Our prototype, called Substitutable Medical Applications and Reusable Technology (SMART)® PCM, visualizes genomic information in real time, comparing a patient's diagnosis-specific somatic gene mutations detected by PCR-based hotspot testing to a population-level set of comparable data. The initial prototype works for patient specimens with 0 or 1 detected mutation. Genomics extensions were created for the Health Level Seven® Fast Healthcare Interoperability Resources (FHIR)® standard; otherwise, the prototype is a normal SMART on FHIR app. The PCM prototype can rapidly present a visualization that compares a patient's somatic genomic alterations against a distribution built from more than 3000 patients, along with context-specific links to external knowledge bases. Initial evaluation by oncologists provided important feedback about the prototype's strengths and weaknesses. We added several requested enhancements and successfully demonstrated the app at the inaugural American Society of Clinical Oncology Interoperability Demonstration; we have also begun to expand visualization capabilities to include cancer specimens with multiple mutations. PCM is open-source software for clinicians to present the individual patient within the population-level spectrum of cancer somatic mutations. The app can be implemented on any SMART on FHIR-enabled EHRs, and future versions of PCM should be able to evolve in parallel with external knowledge bases. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Huang, Yi; Zhu, Youjie; Yang, Mengshi; Zhang, Zhenqing; Song, Donglin; Yuan, Zhiming
2014-12-01
Full-length nucleoproteins from Ebola and Marburg viruses were expressed as His-tagged recombinant proteins in Escherichia coli and nucleoprotein-based enzyme-linked immunosorbent assays (ELISAs) were established for the detection of antibodies specific to Ebola and Marburg viruses. The ELISAs were evaluated by testing antisera collected from rabbit immunized with Ebola and Marburg virus nucleoproteins. Although little cross-reactivity of antibodies was observed in anti-Ebola virus nucleoprotein rabbit antisera, the highest reactions to immunoglobulin G (IgG) were uniformly detected against the nucleoprotein antigens of homologous viruses. We further evaluated the ELISA's ability to detect antibodies to Ebola and Marburg viruses using human sera samples collected from individuals passing through the Guangdong port of entry. With a threshold set at the mean plus three standard deviations of average optical densities of sera tested, the ELISA systems using these two recombinant nucleoproteins have good sensitivity and specificity. These results demonstrate the usefulness of ELISA for diagnostics as well as ecological and serosurvey studies of Ebola and Marburg virus infection.
Eddy Current System for Detection of Cracking Beneath Braiding in Corrugated Metal Hose
NASA Astrophysics Data System (ADS)
Wincheski, Buzz; Simpson, John; Hall, George
2009-03-01
In this paper an eddy current system for the detection of partially-through-the-thickness cracks in corrugated metal hose is presented. Design criteria based upon the geometry and conductivity of the part are developed and applied to the fabrication of a prototype inspection system. Experimental data are used to highlight the capabilities of the system and an image processing technique is presented to improve flaw detection capabilities. A case study for detection of cracking damage in a space shuttle radiator retract flex hoses is also presented.
Eddy Current System for Detection of Cracking Beneath Braiding in Corrugated Metal Hose
NASA Technical Reports Server (NTRS)
Wincheski, Buzz; Simpson, John; Hall, George
2008-01-01
In this paper an eddy current system for the detection of partially-through-the-thickness cracks in corrugated metal hose is presented. Design criteria based upon the geometry and conductivity of the part are developed and applied to the fabrication of a prototype inspection system. Experimental data are used to highlight the capabilities of the system and an image processing technique is presented to improve flaw detection capabilities. A case study for detection of cracking damage in a space shuttle radiator retract flex hoses is also presented.
Study and realization of an obstacle detection infrared system for automotive use
NASA Astrophysics Data System (ADS)
Alaouiamine, Mohammed
1991-08-01
The main technological options available in the field of obstacle detection are presented. Ultrasound, microwave, and infrared detection systems are reviewed. The reasons for choosing an infrared solution are outlined. The problems involved in developing an obstacle detection system in the near infrared are discussed. Weather condition effects, interference limitations due to multiple onboard sensors, and range detection influence are some of the problems studied. A collimated, mechanically scanned, and pulsed infrared beam is proposed to overcome some of these problems. Performances of a first and second prototype made using this system are presented.
Direct and indirect light emissions from layered ReS2-x Se x (0 ≤ x ≤ 2)
NASA Astrophysics Data System (ADS)
Ho, Ching-Hwa; Liu, Zhan-Zhi; Lin, Min-Han
2017-06-01
ReS2 and ReSe2 have recently been enthusiastically studied owing to the specific in-plane electrical, optical and structural anisotropy caused by their distorted one-layer trigonal (1 T) phase, whereas other traditional transition-metal dichalcogenides (TMDCs, e.g. MoS2 and WSe2) have a hexagonal structure. Because of this special property, more and versatile nano-electronics and nano-optoelectronics devices can be developed. In this work, 2D materials in the series ReS2-x Se x (0 ≤ x ≤ 2) have been successfully grown by the method of chemical vapor transport. The direct and indirect resonant emissions of the complete series of layers can be simultaneously detected by polarized micro-photoluminescence (μPL) spectroscopy when the thickness of the ReS2-x Se x is greater than ˜70 nm. When it is less than 70 nm, only three direct excitonic emissions—E 1 ex, E 2 ex and E S ex—are detected. For the thick (bulk) ReS2-x Se x , more stacking of the ReX2 monolayers even flattens and shifts the valence-band maximum from Γ to the other K- or M-related points, thus leading to the coexistence of direct and indirect resonant light emissions from the c-plane ReX2. The transmittance absorption edge of each bulk ReX2 (a few microns thick) usually has a lower energy than those of the direct E 1 ex and E 2 ex excitonic emissions to form indirect absorption. The coexistence of direct and indirect emissions in ReX2 is a unique characteristic of a 2D layered semiconductor possessing triclinic low symmetry.
Horowitz, A.J.; Smith, J.J.; Elrick, K.A.
2001-01-01
A prototype 14-L Teflon? churn splitter was evaluated for whole-water sample-splitting capabilities over a range of sediment concentratons and grain sizes as well as for potential chemical contamination from both organic and inorganic constituents. These evaluations represent a 'best-case' scenario because they were performed in the controlled environment of a laboratory, and used monomineralic silica sand slurries of known concentration made up in deionized water. Further, all splitting was performed by a single operator, and all the requisite concentration analyses were performed by a single laboratory. The prototype Teflon? churn splitter did not appear to supply significant concentrations of either organic or inorganic contaminants at current U.S. Geological Survey (USGS) National Water Quality Laboratory detection and reporting limits when test samples were prepared using current USGS protocols. As with the polyethylene equivalent of the prototype Teflon? churn, the maximum usable whole-water suspended sediment concentration for the prototype churn appears to lie between 1,000 and 10,000 milligrams per liter (mg/L). Further, the maximum grain-size limit appears to lie between 125- and 250-microns (m). Tests to determine the efficacy of the valve baffle indicate that it must be retained to facilitate representative whole-water subsampling.
Air injection test on a Kaplan turbine: prototype - model comparison
NASA Astrophysics Data System (ADS)
Angulo, M.; Rivetti, A.; Díaz, L.; Liscia, S.
2016-11-01
Air injection is a very well-known resource to reduce pressure pulsation magnitude in turbines, especially on Francis type. In the case of large Kaplan designs, even when not so usual, it could be a solution to mitigate vibrations arising when tip vortex cavitation phenomenon becomes erosive and induces structural vibrations. In order to study this alternative, aeration tests were performed on a Kaplan turbine at model and prototype scales. The research was focused on efficiency of different air flow rates injected in reducing vibrations, especially at the draft tube and the discharge ring and also in the efficiency drop magnitude. It was found that results on both scales presents the same trend in particular for vibration levels at the discharge ring. The efficiency drop was overestimated on model tests while on prototype were less than 0.2 % for all power output. On prototype, air has a beneficial effect in reducing pressure fluctuations up to 0.2 ‰ of air flow rate. On model high speed image computing helped to quantify the volume of tip vortex cavitation that is strongly correlated with the vibration level. The hydrophone measurements did not capture the cavitation intensity when air is injected, however on prototype, it was detected by a sonometer installed at the draft tube access gallery.
Liu, Rongchang; Chen, Cuiteng; Cheng, Longfei; Lu, Ronghui; Fu, Guanghua; Shi, Shaohua; Chen, Hongmei; Wan, Chunhe; Lin, Jiansheng; Fu, Qiuling; Huang, Yu
2017-07-28
Pasteurella multocida is an important pathogen of numerous domestic poultry and wild animals and is associated with a variety of diseases including fowl cholera. The aim of this study was to develop an indirect enzyme-linked immunosorbent assay (ELISA) based on recombinant outer-membrane protein H (rOmpH) for detection of anti-P. multocida antibodies in serum to determine their prevalence in Chinese ducks. The P. multocida ompH gene was cloned into pET32a, and rOmpH was expressed in Escherichia coli BL21 (DE3). Western blotting revealed that purified rOmpH was recognized by duck antisera against P. multocida, and an indirect ELISA was established. During analysis of serum samples (n=115) from ducks, the rOmpH ELISA showed 95.0% specificity, 100% sensitivity and a 92.0% κ coefficient (95% confidence interval 0.844-0.997) as compared with a microtiter agglutination test. Among 165 randomly selected serum samples, which were collected in 2015 and originated from six duck farms across Fujian Province, China, anti-P. multocida antibodies were detected in 22.42% of apparently healthy ducks, including 25 of 90 sheldrakes (27.8%), eight of 50 Peking ducks (16.0%) and four of 25 Muscovy ducks (16%). Overall, the data suggest that rOmpH is a suitable candidate antigen for the development of an indirect ELISA for detection of P. multocida in ducks; moreover, our results showed that ducks could serve as a potential reservoir for P. multocida infection.
Autologous Blood Transfusion in Sports: Emerging Biomarkers.
Salamin, Olivier; De Angelis, Sara; Tissot, Jean-Daniel; Saugy, Martial; Leuenberger, Nicolas
2016-07-01
Despite being prohibited by the World Anti-Doping Agency, blood doping through erythropoietin injection or blood transfusion is frequently used by athletes to increase oxygen delivery to muscles and enhance performance. In contrast with allogeneic blood transfusion and erythropoietic stimulants, there is presently no direct method of detection for autologous blood transfusion (ABT) doping. Blood reinfusion is currently monitored with individual follow-up of hematological variables via the athlete biological passport, which requires further improvement. Microdosage is undetectable, and suspicious profiles in athletes are often attributed to exposure to altitude, heat stress, or illness. Additional indirect biomarkers may increase the sensitivity and specificity of the longitudinal approach. The emergence of "-omics" strategies provides new opportunities to discover biomarkers for the indirect detection of ABT. With the development of direct quantitative methods, transcriptomics based on microRNA or messenger RNA expression is a promising approach. Because blood donation and blood reinfusion alter iron metabolism, quantification of proteins involved in metal metabolism, such as hepcidin, may be applied in an "ironomics" strategy to improve the detection of ABT. As red blood cell (RBC) storage triggers changes in membrane proteins, proteomic methods have the potential to identify the presence of stored RBCs in blood. Alternatively, urine matrix can be used for the quantification of the plasticizer di(2-ethyhexyl)phthalate and its metabolites that originate from blood storage bags, suggesting recent blood transfusion, and have an important degree of sensitivity and specificity. This review proposes that various indirect biomarkers should be applied in combination with mathematical approaches for longitudinal monitoring aimed at improving ABT detection. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Harnawan, A. A.; Mariati; Fahrudin, A.; Assegaf, A.
2017-05-01
Recently, EBT has been proven as the marker of airways inflammation like asthma and proposed as the non-invasive tool. Although EBT device has already been made but this device is rarely used for patients in Indonesia. The aim of this study is to develop a prototype which accurately measures EBT and is comfortably used by patients including children. This prototype was made using SHT11 as a sensor of EBT which is integrated on a thermal flask 0.5L. This flask filled up patient breath and the temperature of air breath was measured. The EBT of twelve healthy samples and seven samples with asthma was examined using this prototype, the measurement was done within three minutes for all of them. The test results of EBT on healthy samples obtained the median is 33.9°C within of 33.0°C - 34.7°C and EBT on asthma samples obtained median is 35.0°C within the range 34.9°C - 36.0°C.
1997-08-01
anti-neu antibody response of DNA vaccine immunized mice again by indirectly flowcytometry assay, we confirm our previous finding. We also examine the... flowcytometry assay, I have confirmed my previous finding from Elisa assay. 5 I also examined the cellular immunity response of DNA immunized mice by CTL...immunized mice by indirectly flowcytometry assay. I also find mice immunized with neu DNA vaccine did not develop detectable cytotoxic T lymphocyte
Kimori, Keiko; Sugama, Junko; Nakatani, Toshio; Nakayama, Kazuya; Miyati, Tosiaki; Sanada, Hiromi
2015-01-01
To compare the performance on the detection of the invisible veins between our modified prototype device and an existing device in elderly hospitalized patients. A prospective, cross-sectional, and observational study was performed in the invisible veins in elderly patients. The major variables, skin color near the invisible veins, and diameter and depth of the invisible veins were measured. The vein visualization rate was calculated as the ratio of the visualized veins to the invisible veins by the visualization device. We analyzed 53 invisible veins in the cubital fossa and 56 invisible veins in the forearm in a total of 72 patients (median age, 73 years). The visualization rate for our prototype device was higher than that for an existing device in the cubital fossa and the forearm sites. The visualized veins of the prototype device had a higher intensity ratio than that of an existing device. No significant differences were observed in the body mass index, vein depth, and vein diameter of the visualized veins at the cubital fossa and forearm sites. The prototype surpassed the existing device in visualizing the invisible veins. However, the prototype was unable to visualize all the invisible veins. We need to look for ways to reduce noise and to visualize the invisible veins, and the visualization rate of devices needs to be investigated in further association with the percentage of success with actual intravenous access and locating time to vein.
Development of an Electron-capture Technique Specific for Explosives Detection
DOT National Transportation Integrated Search
1974-07-01
This document contains information on the design, fabrication, and testing of a prototype detector specific for explosives which employs electron-capture sensors. The technique used exploits the observation that the electronegative vapors from explos...
Open ISEmeter: An open hardware high-impedance interface for potentiometric detection.
Salvador, C; Mesa, M S; Durán, E; Alvarez, J L; Carbajo, J; Mozo, J D
2016-05-01
In this work, a new open hardware interface based on Arduino to read electromotive force (emf) from potentiometric detectors is presented. The interface has been fully designed with the open code philosophy and all documentation will be accessible on web. The paper describes a comprehensive project including the electronic design, the firmware loaded on Arduino, and the Java-coded graphical user interface to load data in a computer (PC or Mac) for processing. The prototype was tested by measuring the calibration curve of a detector. As detection element, an active poly(vinyl chloride)-based membrane was used, doped with cetyltrimethylammonium dodecylsulphate (CTA(+)-DS(-)). The experimental measures of emf indicate Nernstian behaviour with the CTA(+) content of test solutions, as it was described in the literature, proving the validity of the developed prototype. A comparative analysis of performance was made by using the same chemical detector but changing the measurement instrumentation.
Capriotti, Margherita; Kim, Hyungsuk E; Scalea, Francesco Lanza di; Kim, Hyonny
2017-06-04
This paper discusses a non-destructive evaluation (NDE) technique for the detection of damage in composite aircraft structures following high energy wide area blunt impact (HEWABI) from ground service equipment (GSE), such as heavy cargo loaders and other heavy equipment. The test structures typically include skin, co-cured stringers, and C-frames that are bolt-connected onto the skin with shear ties. The inspection exploits the waveguide geometry of these structures by utilizing ultrasonic guided waves and a line scan approach. Both a contact prototype and a non-contact prototype were developed and tested on realistic test panels subjected to impact in the laboratory. The results are presented in terms of receiver operating characteristic curves that show excellent probability of detection with low false alarm rates for defects located in the panel skin and stringers.
Quintella, Cristina M; Meira, Marilena; Silva, Weidson Leal; Filho, Rogério G D; Araújo, André L C; Júnior, Elias T S; Sales, Lindolfo J O
2013-12-15
Power transformers are essential for a functioning electrical system and therefore require special attention by maintenance programs because a fault can harm both the company and society. The temperature inside a power transformer and the dissolved gases, which are primarily composed of acetylene, are the two main parameters monitored when detecting faults. This paper describes the development of a device for analyzing the acetylene content in insulating oil using spectrofluorimetry. Using this device introduces a new methodology for the maintaining and operating power transformers. The prototype is currently operating in a substation. The results presented by this system were satisfactory; when compared to chromatographic data, the errors did not exceed 15%. This prototype may be used to confirm the quality of an insulating oil sample to detect faults in power transformers. © 2013 Elsevier B.V. All rights reserved.
Capriotti, Margherita; Kim, Hyungsuk E.; Lanza di Scalea, Francesco; Kim, Hyonny
2017-01-01
This paper discusses a non-destructive evaluation (NDE) technique for the detection of damage in composite aircraft structures following high energy wide area blunt impact (HEWABI) from ground service equipment (GSE), such as heavy cargo loaders and other heavy equipment. The test structures typically include skin, co-cured stringers, and C-frames that are bolt-connected onto the skin with shear ties. The inspection exploits the waveguide geometry of these structures by utilizing ultrasonic guided waves and a line scan approach. Both a contact prototype and a non-contact prototype were developed and tested on realistic test panels subjected to impact in the laboratory. The results are presented in terms of receiver operating characteristic curves that show excellent probability of detection with low false alarm rates for defects located in the panel skin and stringers. PMID:28772976
Mera, David; Cotos, José M; Varela-Pet, José; Garcia-Pineda, Oscar
2012-10-01
Satellite Synthetic Aperture Radar (SAR) has been established as a useful tool for detecting hydrocarbon spillage on the ocean's surface. Several surveillance applications have been developed based on this technology. Environmental variables such as wind speed should be taken into account for better SAR image segmentation. This paper presents an adaptive thresholding algorithm for detecting oil spills based on SAR data and a wind field estimation as well as its implementation as a part of a functional prototype. The algorithm was adapted to an important shipping route off the Galician coast (northwest Iberian Peninsula) and was developed on the basis of confirmed oil spills. Image testing revealed 99.93% pixel labelling accuracy. By taking advantage of multi-core processor architecture, the prototype was optimized to get a nearly 30% improvement in processing time. Copyright © 2012 Elsevier Ltd. All rights reserved.
Advanced Opto-Electronics (LIDAR and Microsensor Development)
NASA Technical Reports Server (NTRS)
Vanderbilt, Vern C. (Technical Monitor); Spangler, Lee H.
2005-01-01
Our overall intent in this aspect of the project were to establish a collaborative effort between several departments at Montana State University for developing advanced optoelectronic technology for advancing the state-of-the-art in optical remote sensing of the environment. Our particular focus was on development of small systems that can eventually be used in a wide variety of applications that might include ground-, air-, and space deployments, possibly in sensor networks. Specific objectives were to: 1) Build a field-deployable direct-detection lidar system for use in measurements of clouds, aerosols, fish, and vegetation; 2) Develop a breadboard prototype water vapor differential absorption lidar (DIAL) system based on highly stable, tunable diode laser technology developed previously at MSU. We accomplished both primary objectives of this project, in developing a field-deployable direct-detection lidar and a breadboard prototype of a water vapor DIAL system. Paper summarizes each of these accomplishments.
Almahmoud, Safieh; Vahdati, Nader; Rostron, Paul
2018-01-01
A monitoring solution was developed for detection of material loss in metals such as carbon steel using the force generated by permanent magnets in addition to the optical strain sensing technology. The working principle of the sensing system is related to the change in thickness of a steel plate, which typically occurs due to corrosion. As thickness decreases, the magnetostatic force between the magnet and the steel structure also decreases. This, in turn, affects the strain measured using the optical fiber. The sensor prototype was designed and built after verifying its sensitivity using a numerical model. The prototype was tested on steel plates of different thicknesses to establish the relationship between the metal thickness and measured strain. The results of experiments and numerical models demonstrate a strong relationship between the metal thickness and the measured strain values. PMID:29518006
Research on ground-based LWIR hyperspectral imaging remote gas detection
NASA Astrophysics Data System (ADS)
Yang, Zhixiong; Yu, Chunchao; Zheng, Weijian; Lei, Zhenggang; Yan, Min; Yuan, Xiaochun; Zhang, Peizhong
2015-10-01
The new progress of ground-based long-wave infrared remote sensing is presented, which describes the windowing spatial and temporal modulation Fourier spectroscopy imaging in details. The prototype forms the interference fringes based on the corner-cube of spatial modulation of Michelson interferometer, using cooled long-wave infrared photovoltaic staring FPA (focal plane array) detector. The LWIR hyperspectral imaging is achieved by the process of collection, reorganization, correction, apodization, FFT etc. from data cube. Noise equivalent sensor response (NESR), which is the sensitivity index of CHIPED-1 LWIR hyperspectral imaging prototype, can reach 5.6×10-8W/(cm-1.sr.cm2) at single sampling. Hyperspectral imaging is used in the field of organic gas VOC infrared detection. Relative to wide band infrared imaging, it has some advantages. Such as, it has high sensitivity, the strong anti-interference ability, identify the variety, and so on.
Iron Abundance in the Prototype PG 1159 Star, GW Vir Pulsator PG 1159-035, and Related Objects
NASA Technical Reports Server (NTRS)
Werner, K.; Rauch, T.; Kruk, J. W.; Kurucz, R. L.
2011-01-01
We performed an iron abundance determination of the hot, hydrogen deficient post-AGB star PG 1159-035. which is the prototype of the PG 1159 spectral class and the GW Vir pulsators, and of two related objects (PG 1520+525, PG 1144+005), based on the first detection of Fe VIII lines in stellar photospheres. In another PG 1159 star. PG 1424+535. we detect Fe VII lines. In all four stars, each within T(sub eff) = 110,000-150,000 K, we find a solar iron abundance. This result agrees with our recent abundance analysis of the hottest PG 1159 stars (T(sub eff) = 150,000-200,000 K) that exhibit Fe x lines. On the whole, we find that the PG 1159 stars are not significantly iron deficient, in contrast to previous notions.
Prototype detection unit for the CHIPS experiment
NASA Astrophysics Data System (ADS)
Pfützner, Maciej M.
2017-09-01
CHIPS (CHerenkov detectors In mine PitS) is an R&D project aiming to develop novel cost-effective neutrino detectors, focused on measuring the CP-violating neutrino mixing phase (δ CP). A single detector module, containing an enclosed volume of purified water, would be submerged in an existing lake, located in a neutrino beam. A staged approach is proposed with first detectors deployed in a flooded mine pit in Northern Minnesota, 7 mrad off-axis from the existing NuMI beam. A small proof-of-principle model (CHIPS-M) has already been tested and the first stage of a fully functional 10 kt module (CHIPS-10) is planned for 2018. One of the instruments submerged on board of CHIPS-M in autumn 2015 was a prototype detection unit, constructed at Nikhef. The unit contains hardware borrowed from the KM3NeT experiment, including 16 3 inch photomultiplier tubes and readout electronics. In addition to testing the mechanical design and data acquisition, the detector was used to record a large sample of cosmic ray muon events. The collected data is valuable for characterising the cosmic muon background and validating a Monte Carlo simulation used to optimise future designs. This paper introduces the CHIPS project, describes the design of the prototype unit, and presents the results of a preliminary data analysis.
NASA Astrophysics Data System (ADS)
Versini, P.-A.; Gaume, E.; Andrieu, H.
2010-04-01
This paper presents an initial prototype of a distributed hydrological model used to map possible road inundations in a region frequently exposed to severe flash floods: the Gard region (South of France). The prototype has been tested in a pseudo real-time mode on five recent flash flood events for which actual road inundations have been inventoried. The results are promising: close to 100% probability of detection of actual inundations, inundations detected before they were reported by the road management field teams with a false alarm ratios not exceeding 30%. This specific case study differs from the standard applications of rainfall-runoff models to produce flood forecasts, focussed on a single or a limited number of gauged river cross sections. It illustrates that, despite their lack of accuracy, hydro-meteorological forecasts based on rainfall-runoff models, especially distributed models, contain valuable information for flood event management. The possible consequences of landslides, debris flows and local erosion processes, sometimes associated with flash floods, were not considered at this stage of development of the prototype. They are limited in the Gard region but should be taken into account in future developments of the approach to implement it efficiently in other areas more exposed to these phenomena such as the Alpine area.
Marchevsky, M.; Ambrosio, G.; Lamm, M.; ...
2016-02-12
Acoustic emission (AE) detection is a noninvasive technique allowing the localization of the mechanical events and quenches in superconducting magnets. Application of the AE technique is especially advantageous in situations where magnet integrity can be jeopardized by the use of voltage taps or inductive pickup coils. As the prototype module of the transport solenoid (TS) for the Mu2e experiment at Fermilab represents such a special case, we have developed a dedicated six-channel AE detection system and accompanying software aimed at localizing mechanical events during the coil cold testing. The AE sensors based on transversely polarized piezoceramic washers combined with cryogenicmore » preamplifiers were mounted at the outer surface of the solenoid aluminum shell, with a 60° angular step around the circumference. Acoustic signals were simultaneously acquired at a rate of 500 kS/s, prefiltered and sorted based on their arrival time. Next, based on the arrival timing, angular and axial coordinates of the AE sources within the magnet structure were calculated. Furthermore, we present AE measurement results obtained during cooldown, spot heater firing, and spontaneous quenching of the Mu2e TS module prototype and discuss their relevance for mechanical stability assessment and quench localization.« less
An ion source for radiofrequency-pulsed glow discharge time-of-flight mass spectrometry
NASA Astrophysics Data System (ADS)
González Gago, C.; Lobo, L.; Pisonero, J.; Bordel, N.; Pereiro, R.; Sanz-Medel, A.
2012-10-01
A Grimm-type glow discharge (GD) has been designed and constructed as an ion source for pulsed radiofrequency GD spectrometry when coupled to an orthogonal time of flight mass spectrometer. Pulse shapes of argon species and analytes were studied as a function of the discharge conditions using a new in-house ion source (UNIOVI GD) and results have been compared with a previous design (PROTOTYPE GD). Different behavior and shapes of the pulse profiles have been observed for the two sources evaluated, particularly for the plasma gas ionic species detected. In the more analytically relevant region (afterglow), signals for 40Ar+ with this new design were negligible, while maximum intensity was reached earlier in time for 41(ArH)+ than when using the PROTOTYPE GD. Moreover, while maximum 40Ar+ signals measured along the pulse period were similar in both sources, 41(ArH)+ and 80(Ar2)+ signals tend to be noticeable higher using the PROTOTYPE chamber. The UNIOVI GD design was shown to be adequate for sensitive direct analysis of solid samples, offering linear calibration graphs and good crater shapes. Limits of detection (LODs) are in the same order of magnitude for both sources, although the UNIOVI source provides slightly better LODs for those analytes with masses slightly higher than 41(ArH)+.
The efficacy of three objective systems for identifying beef cuts that can be guaranteed tender.
Wheeler, T L; Vote, D; Leheska, J M; Shackelford, S D; Belk, K E; Wulf, D M; Gwartney, B L; Koohmaraie, M
2002-12-01
The objective of this study was to determine the accuracy of three objective systems (prototype BeefCam, colorimeter, and slice shear force) for identifying guaranteed tender beef. In Phase I, 308 carcasses (105 Top Choice, 101 Low Choice, and 102 Select) from two commercial plants were tested. In Phase II, 400 carcasses (200 rolled USDA Select and 200 rolled USDA Choice) from one commercial plant were tested. The three systems were evaluated based on progressive certification of the longissimus as "tender" in 10% increments (the best 10, 20, 30%, etc., certified as "tender" by each technology; 100% certification would mean no sorting for tenderness). In Phase I, the error (percentage of carcasses certified as tender that had Warner-Bratzler shear force of > or = 5 kg at 14 d postmortem) for 100% certification using all carcasses was 14.1%. All certification levels up to 80% (slice shear force) and up to 70% (colorimeter) had less error (P < 0.05) than 100% certification. Errors in all levels of certification by prototype BeefCam (13.8 to 9.7%) were not different (P > 0.05) from 100% certification. In Phase I, the error for 100% certification for USDA Select carcasses was 30.7%. For Select carcasses, all slice shear force certification levels up to 60% (0 to 14.8%) had less error (P < 0.05) than 100% certification. For Select carcasses, errors in all levels of certification by colorimeter (20.0 to 29.6%) and by BeefCam (27.5 to 31.4%) were not different (P > 0.05) from 100% certification. In Phase II, the error for 100% certification for all carcasses was 9.3%. For all levels of slice shear force certification less than 90% (for all carcasses) or less than 80% (Select carcasses), errors in tenderness certification were less than (P < 0.05) for 100% certification. In Phase II, for all carcasses or Select carcasses, colorimeter and prototype BeefCam certifications did not significantly reduce errors (P > 0.05) compared to 100% certification. Thus, the direct measure of tenderness provided by slice shear force results in more accurate identification of "tender" beef carcasses than either of the indirect technologies, prototype BeefCam, or colorimeter, particularly for USDA Select carcasses. As tested in this study, slice shear force, but not the prototype BeefCam or colorimeter systems, accurately identified "tender" beef.
Mars Spark Source Prototype Developed
NASA Technical Reports Server (NTRS)
Eichenberg, Dennis J.; Lindamood, Glenn R.; VanderWal, Randall L.; Weiland, Karen J.
2000-01-01
The Mars Spark Source Prototype (MSSP) hardware was developed as part of a proof of concept system for the detection of trace metals such as lead, cadmium, and arsenic in Martian dusts and soils. A spark discharge produces plasma from a soil sample, and detectors measure the optical emission from metals in the plasma to identify and quantify them. Trace metal measurements are vital in assessing whether or not the Martian environment will be toxic to human explorers. The current method of x-ray fluorescence can yield concentrations of major species only. Other instruments are incompatible with the volume, weight, and power constraints for a Mars mission. The new instrument will be developed primarily for use in the Martian environment, but it would be adaptable for terrestrial use in environmental monitoring. The NASA Glenn Research Center at Lewis Field initiated the development of the MSSP as part of Glenn's Director's Discretionary Fund project for the Spark Analysis Detection of Trace Metal Species in Martian Dusts and Soils. The objective of this project is to develop and demonstrate a compact, sensitive optical instrument for the detection of trace hazardous metals in Martian dusts and soils.
Advanced Fire Detector for Space Applications
NASA Technical Reports Server (NTRS)
Kutzner, Joerg
2012-01-01
A document discusses an optical carbon monoxide sensor for early fire detection. During the sensor development, a concept was implemented to allow reliable carbon monoxide detection in the presence of interfering absorption signals. Methane interference is present in the operating wavelength range of the developed prototype sensor for carbon monoxide detection. The operating parameters of the prototype sensor have been optimized so that interference with methane is minimized. In addition, simultaneous measurement of methane is implemented, and the instrument automatically corrects the carbon monoxide signal at high methane concentrations. This is possible because VCSELs (vertical cavity surface emitting lasers) with extended current tuning capabilities are implemented in the optical device. The tuning capabilities of these new laser sources are sufficient to cover the wavelength range of several absorption lines. The delivered carbon monoxide sensor (COMA 1) reliably measures low carbon monoxide levels even in the presence of high methane signals. The signal bleed-over is determined during system calibration and is then accounted for in the system parameters. The sensor reports carbon monoxide concentrations reliably for (interfering) methane concentrations up to several thousand parts per million.
A One ppm NDIR Methane Gas Sensor with Single Frequency Filter Denoising Algorithm
Zhu, Zipeng; Xu, Yuhui; Jiang, Binqing
2012-01-01
A non-dispersive infrared (NDIR) methane gas sensor prototype has achieved a minimum detection limit of 1 parts per million by volume (ppm). The central idea of the design of the sensor is to decrease the detection limit by increasing the signal to noise ratio (SNR) of the system. In order to decrease the noise level, a single frequency filter algorithm based on fast Fourier transform (FFT) is adopted for signal processing. Through simulation and experiment, it is found that the full width at half maximum (FWHM) of the filter narrows with the extension of sampling period and the increase of lamp modulation frequency, and at some optimum sampling period and modulation frequency, the filtered signal maintains a noise to signal ratio of below 1/10,000. The sensor prototype provides the key techniques for a hand-held methane detector that has a low cost and a high resolution. Such a detector may facilitate the detection of leakage of city natural gas pipelines buried underground, the monitoring of landfill gas, the monitoring of air quality and so on.
Remote detection of explosives using Raman spectroscopy
NASA Astrophysics Data System (ADS)
Fulton, Jack
2011-05-01
Stand-off detection of potentially hazardous small molecules at distances that allow the user to be safe has many applications, including explosives and chemical threats. The Naval Surface Warfare Center, Crane Division, with EYZtek, Inc. of Ohio, developed a prototype stand-off, eye-safe Raman spectrometer. With a stand-off distance greater than twenty meters and scanning optics, this system has the potential of addressing particularly difficult challenges in small molecule detection. An overview of the system design and desired application space is presented.
Programmed Pathogen Sense and Destroy Circuits
2009-02-18
detection and the peptide-mediated Com QS system of Bacillus subtilis for gram-positive detection. Together these two prototype sentinel circuits cover a...and E. coli. We are currently in the process of constructing receivers for a gram-positive pathogen, Bacillus subtilis . Gram-negative...QS signals. Figure 11: Gram positive QS systems. Agr QS of Staphylococcus aureus (left) and Com QS of Bacillus subtilis . Following the successful
Infrared microchip and signal receiver being developed
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-01-01
ORNL researchers have developed both a solar-powered microtransmitter system that emits an infrared signal as well as a prototype detection system that detect the signal from a distance at least twice as far as can be sent by current transmitters of comparable size. This technology can be used to study mating and foraging habits of Africanized bees, as well as a number of other applications.
[Comparison of several methods for detecting anti-erythrocyte alloantibodies].
Bencomo, A A
1990-08-01
The efficacy of different methods for anti-red cell antibodies detection was assessed, variations being found in accordance with the specificity of the alloantibodies. The usefulness of enzyme tests in anti-Rh antibody detection was demonstrated, as well as that of low ionic strength saline solutions in detecting anti-Kell, anti-Duffy and anti-Kidd antibodies. Serum precipitation with 15% polyethyleneglycol 8000 previously to indirect antiglobulin test was found the most sensitive method, providing the best results in all the antibodies studied.
The spindle kinesin-like protein HsEg5 is an autoantigen in systemic lupus erythematosus.
Whitehead, C M; Winkfein, R J; Fritzler, M J; Rattner, J B
1996-10-01
Autoantibodies directed against the mitotic spindle apparatus (MSA) have been shown to target an antigen referred to as NuMA (nuclear mitotic apparatus). In this study, we identified a second MSA antigen as the spindle kinesin-like protein HsEg5. We studied the frequency of antibodies to HsEg5 in human sera that demonstrate the MSA pattern of staining, the frequency of autoantibodies to HsEg5 in patients with systemic lupus erythematosus (SLE), and the clinical features of patients with antibodies to HsEg5. A prototype serum from an SLE patient was used to isolate a 4.8-kilobase complementary DNA (cDNA) from a HeLa cDNA library. Western blot, immunoprecipitation, and sequence analysis revealed that the antigen was an approximately 130-kd protein, HsEg5. The frequency of autoantibodies to recombinant HsEg5 in 51 sera that demonstrated an MSA pattern of staining on HEp-2 and HeLa cells was detected by immunoblotting 2 constructs of the cDNA. The clinical features of patients with antibodies directed against HsEg5 was obtained by retrospective chart review. The antigen responsible for the MSA-35 pattern was identified as the human kinesin-like protein HsEg5. Seven of 51 sera (14%) that demonstrated an MSA pattern of staining reacted with recombinant HsEg5. Six of 7 of the HsEg5-positive patients (86%) had SLE, and 1 had Sjögren's syndrome. The indirect immunofluorescent staining pattern of sera that reacted with HsEg5 could be distinguished from the other sera that reacted with NuMA. In an unselected cohort of 52 SLE patients, 3 (6%) had autoantibodies reactive with the recombinant HsEg5. Autoantibodies to MSA fall into 2 major classes: those reactive with NuMA and those reactive with HsEg5. Autoantibodies to HsEg5 are found in a lower frequency than NuMA in sera that demonstrate the MSA pattern of staining and appear to be specifically associated with SLE. HsEg5 can be distinguished from NuMA by indirect immunofluorescence and Western blotting.
Preliminary testing of a prototype portable X-ray fluorescence spectrometer
NASA Technical Reports Server (NTRS)
Patten, L. L.; Anderson, N. B.; Stevenson, J. J.
1982-01-01
A portable X-ray fluorescence spectrometer for use as an analyzer in mineral resource investigative work was built and tested. The prototype battery powered spectrometer, measuring 11 by 12 by 5 inches and weighing only about 15 pounds, was designed specifically for field use. The spectrometer has two gas proportional counters and two radioactive sources, Cd (10a) and Fe (55). Preliminary field and laboratory tests on rock specimens and rock pulps have demonstrated the capability of the spectrometer to detect 33 elements to date. Characteristics of the system present some limitations, however, and further improvements are recommended.
Speidel, Michael A; Tomkowiak, Michael T; Raval, Amish N; Dunkerley, David A P; Slagowski, Jordan M; Kahn, Paul; Ku, Jamie; Funk, Tobias
Scanning-beam digital x-ray (SBDX) is an inverse geometry fluoroscopy system for low dose cardiac imaging. The use of a narrow scanned x-ray beam in SBDX reduces detected x-ray scatter and improves dose efficiency, however the tight beam collimation also limits the maximum achievable x-ray fluence. To increase the fluence available for imaging, we have constructed a new SBDX prototype with a wider x-ray beam, larger-area detector, and new real-time image reconstructor. Imaging is performed with a scanning source that generates 40,328 narrow overlapping projections from 71 × 71 focal spot positions for every 1/15 s scan period. A high speed 2-mm thick CdTe photon counting detector was constructed with 320×160 elements and 10.6 cm × 5.3 cm area (full readout every 1.28 μs), providing an 86% increase in area over the previous SBDX prototype. A matching multihole collimator was fabricated from layers of tungsten, brass, and lead, and a multi-GPU reconstructor was assembled to reconstruct the stream of captured detector images into full field-of-view images in real time. Thirty-two tomosynthetic planes spaced by 5 mm plus a multiplane composite image are produced for each scan frame. Noise equivalent quanta on the new SBDX prototype measured 63%-71% higher than the previous prototype. X-ray scatter fraction was 3.9-7.8% when imaging 23.3-32.6 cm acrylic phantoms, versus 2.3-4.2% with the previous prototype. Coronary angiographic imaging at 15 frame/s was successfully performed on the new SBDX prototype, with live display of either a multiplane composite or single plane image.
Two Photon Polymerization of Microneedles for Transdermal Drug Delivery
Gittard, Shaun D.; Ovsianikov, Aleksandr; Chichkov, Boris N.; Doraiswamy, Anand; Narayan, Roger J.
2010-01-01
Importance of the field Microneedles are small-scale devices that are finding use for transdermal delivery of protein-based pharmacologic agents and nucleic acid-based pharmacologic agents; however, microneedles prepared using conventional microelectronics-based technologies have several shortcomings, which have limited translation of these devices into widespread clinical use. Areas covered in this review Two photon polymerization is a laser-based rapid prototyping technique that has been recently used for direct fabrication of hollow microneedles with a wide variety of geometries. In addition, an indirect rapid prototyping method that involves two photon polymerization and polydimethyl siloxane micromolding has been used for fabrication of solid microneedles with exceptional mechanical properties. What the reader will gain In this review, the use of two photon polymerization for fabricating in-plane and out-of-plane hollow microneedle arrays is described. The use of two photon polymerization-micromolding for fabrication of solid microneedles is also reviewed. In addition, fabrication of microneedles with antimicrobial properties is discussed; antimicrobial microneedles may reduce the risk of infection associated with formation of channels through the stratum corneum. Take home message It is anticipated that the use of two photon polymerization as well as two photon polymerization-micromolding for fabrication of microneedles and other microstructured drug delivery devices will increase over the coming years. PMID:20205601
Tisch, Ulrike; Haick, Hossam
2014-06-01
Profiling the body chemistry by means of volatile organic compounds (VOCs) in the breath opens exciting new avenues in medical diagnostics. Gas sensors could provide ideal platforms for realizing portable, hand-held breath testing devices in the near future. This review summarizes the latest developments and applications in the field of chemical sensors for diagnostic breath testing that were presented at the Breath Analysis Summit 2013 in Wallerfangen, Germany. Considerable progress has been made towards clinically applicable breath testing devices, especially by utilizing chemo-sensitive nanomaterials. Examples of several specialized breath testing applications are presented that are either based on stand-alone nanomaterial-based sensors being highly sensitive and specific to individual breath compounds over others, or on combinations of several highly specific sensors, or on experimental nanomaterial-based sensors arrays. Other interesting approaches include the adaption of a commercially available MOx-based sensor array to indirect breath testing applications, using a sample pre-concentration method, and the development of compact integrated GC-sensor systems. The recent trend towards device integration has led to the development of fully integrated prototypes of point-of-care devices. We describe and compare the performance of several prototypes that are based on different sensing technologies and evaluate their potential as low-cost and readily available next-generation medical devices.
21 CFR 868.2377 - Apnea monitor.
Code of Federal Regulations, 2011 CFR
2011-04-01
... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...
21 CFR 868.2377 - Apnea monitor.
Code of Federal Regulations, 2014 CFR
2014-04-01
... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...
21 CFR 868.2377 - Apnea monitor.
Code of Federal Regulations, 2010 CFR
2010-04-01
... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...
21 CFR 868.2377 - Apnea monitor.
Code of Federal Regulations, 2013 CFR
2013-04-01
... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...
21 CFR 868.2377 - Apnea monitor.
Code of Federal Regulations, 2012 CFR
2012-04-01
... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...
NASA Astrophysics Data System (ADS)
Schlosser, D. M.; Hartmann, R.; Kalok, D.; Bechteler, A.; Abboud, A.; Shokr, M.; Çonka, T.; Pietsch, U.; Strüder, L.
2017-04-01
By combining a low noise fully depleted pnCCD detector with a columnar CsI(Tl) scintillator an energy dispersive spatial resolving detector can be realized with a high quantum efficiency in the range from below 0.5 keV to above 150 keV. The used scintillator system increases the pulse height of gamma-rays converted in the CsI(Tl), due to focusing properties of the columnar scintillator structure by reducing the event size in indirect detection mode (conversion in the scintillator). In case of direct detection (conversion in the silicon of the pnCCD) the relative energy resolution is 0.7% at 122 keV (FWHM = 850 eV) and the spatial resolution is less than 75 μm. In case of indirect detection the relative energy resolution, integrated over all event sizes is about 9% at 122 keV with an expected spatial precision of below 75 μm.
Indirect signals from solar dark matter annihilation to long-lived right-handed neutrinos
Allahverdi, Rouzbeh; Gao, Yu; Knockel, Bradley; ...
2017-04-04
In this paper, we study indirect detection signals from solar annihilation of dark matter (DM) particles into light right-handed (RH) neutrinos with a mass in a 1–5 GeV range. These RH neutrinos can have a sufficiently long lifetime to allow them to decay outside the Sun, and their delayed decays can result in a signal in gamma rays from the otherwise “dark” solar direction, and also a neutrino signal that is not suppressed by the interactions with solar medium. We find that the latest Fermi-LAT and IceCube results place limits on the gamma ray and neutrino signals, respectively. Combined photonmore » and neutrino bounds can constrain the spin-independent DM-nucleon elastic scattering cross section better than direct detection experiments for DM masses from 200 GeV up to several TeV. Finally, the bounds on spin-dependent scattering are also much tighter than the strongest limits from direct detection experiments.« less
Myint, K S; Linthicum, K J; Tanskul, P; Lerdthusnee, K; Vaughn, D W; Manomuth, C; Mongkolsirichaikul, D; Hansukjariya, P; Hastriter, M W
1998-07-01
Immunocytochemical methods were developed and tested for their ability to detect the distribution of Orientia tsutsugamushi in paraffin sections of adult chiggers (Leptotrombidium imphalum Vercammen-Grandjean & Langston). Rickettsial antigen was detected by application of a simple direct or amplified immunocytochemistry procedure and an indirect immunofluorescent procedure. In the direct procedure alkaline phosphatase conjugation to the mouse polyclonal antibody to the Karp strain was followed by the HistoMark Red test system to detect rickettsial antigen. The amplification procedure used a similar method but used an unlabeled primary antibody followed by secondary biotinylated antimouse IgG, streptavidin-alkaline phosphatase, and the HistoMark Red test system. The immunofluorescent procedure included a biotinylated secondary antibody followed by addition of a streptavidin-FITC conjugate. Specific tissue tropisms in infected chiggers were observed in the salivary glands, nervous tissue, and ovaries of adult female mites in all procedures; however, nonspecific fluorescence of the chigger limited definitive identification of tissue tropisms with the indirect immunofluorescent procedure.
Indirect radioimmunoassay for thymus leukemia (TL) antigens. [Mice, /sup 125/I tracer technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Esmon, N.L.; Little, J.R.
1976-09-01
An indirect radioimmunoassay for thymus leukemia TL antigens has been developed and its specificity documented. The assay makes use of anti-TL antibodies produced in congenic mice (A-Tla/sup b/) and radioiodinated purified rabbit anti-mouse IgG. Using this assay, differences can be detected in the amounts of antigen expressed on thymocytes of the three known phenotypes (TL.1,2,3; TL.2; TL/sup -/) of inbred mouse strains. Significant differences are also detected in comparison of the thymocytes from homozygous TL.1,2,3 mice (A-Tla/sup a/) and heterozygotes from Tla/sup a/ and Tla/sup b/ parents. Optimum conditions for the assay have been established. Its ability to detect antigensmore » on glutaraldehyde-fixed cells and the binding of noncytolytic antibodies on both viable and fixed cells are documented. The assay has also been used to quantitate the changes in TL antigen expression on cells incubated in anti-TL antisera under conditions of antigenic modulation.« less
Gas Leak Detection by Dilution of Atmospheric Oxygen
Lambrecht, Armin; Maier, Eric; Strahl, Thomas; Herbst, Johannes
2017-01-01
Gas leak detection is an important issue in infrastructure monitoring and industrial production. In this context, infrared (IR) absorption spectroscopy is a major measurement method. It can be applied in an extractive or remote detection scheme. Tunable laser spectroscopy (TLS) instruments are able to detect CH4 leaks with column densities below 10 ppm·m from a distance of 30 m in less than a second. However, leak detection of non-IR absorbing gases such as N2 is not possible in this manner. Due to the fact that any leaking gas displaces or dilutes the surrounding background gas, an indirect detection is still possible. It is shown by sensitive TLS measurements of the ambient background concentration of O2 that N2 leaks can be localized with extractive and standoff methods for distances below 1 m. Minimum leak rates of 0.1 mbar·L/s were determined. Flow simulations confirm that the leakage gas typically effuses in a narrow jet. The sensitivity is mainly determined by ambient flow conditions. Compared to TLS detection of CH4 at 1651 nm, the indirect method using O2 at 761 nm is experimentally found to be less sensitive by a factor of 100. However, the well-established TLS of O2 may become a universal tool for rapid leakage screening of vessels that contain unknown or inexpensive gases, such as N2. PMID:29206133
DOE Office of Scientific and Technical Information (OSTI.GOV)
Konopacki, S.; Akbari, H.; Gartland, L.
The U.S. Environmental Protection Agency (EPA) sponsored this project to estimate potential energy and monetary savings resulting from the implementation of light-colored roofs on residential and commercial buildings in major U.S. metropolitan areas. Light-colored roofs reflect more sunlight than dark roofs, so they keep buildings cooler and reduce air-conditioning demand. Typically, rooftops in the United States are dark, and thus there is a potential for saving energy and money by changing to reflective roofs. Naturally, the expected savings are higher in southern, sunny, and cloudless climates. In this study, we make quantitative estimates of reduction in peak power demand andmore » annual cooling electricity use that would result from increasing the reflectivity of the roofs. Since light-colored roofs also reflect heat in the winter, the estimates of annual electricity savings are a net value corrected for the increased wintertime energy use. Savings estimates only include direct reduction in building energy use and do not account for the indirect benefit that would also occur from the reduction in ambient temperature, i.e. a reduction in the heat island effect. This analysis is based on simulations of building energy use, using the DOE-2 building energy simulation program. Our methodology starts with specifying 11 prototypical buildings: single-family residential (old and new), office (old and new), retail store (old and new), school (primary and secondary), health (hospital and nursing home), and grocery store. Most prototypes are simulated with two heating systems: gas furnace and heat pumps. We then perform DOE-2 simulations of the prototypical buildings, with light and dark roofs, in a variety of climates and obtain estimates of the energy use for air conditioning and heating.« less
Boehm, T; Hochmuth, A; Malich, A; Reichenbach, J R; Fleck, M; Kaiser, W A
2001-10-01
Near-infrared (NIR) optical mammography without contrast has a low specificity. The application of optical contrast medium may improve the performance. The concentration-dependent detectability of a new NIR contrast medium was determined with a prototype optical breast scanner. In vivo imaging of experimental tumors was performed. The NIR contrast agent NIR96010 is a newly synthesized, hydrophilic contrast agent for NIR mammography. A concentration-dependent contrast resolution was determined for tissue phantoms consisting of whole milk powder and gelatin. A central part of the phantoms measuring 2 x 2 cm2 without contrast was replaced with phantom material containing 1 micromol/L to 25 nmol/L NIR96010. The composite phantoms were measured with a prototype NIR breast scanner with lasers of lambda1 = 785 nm and lambda2 = 850 nm wavelength. Intensity profiles and standard deviations of the transmission signal in areas with and without contrast were determined by linear fit procedures. Signal-to-noise ratios and spatial resolution as a function of contrast concentration were determined. Near-infrared imaging of five tumor-bearing SCID mice (MX1 breast adenocarcinoma, tumor diameter 5-10 mm) was performed before and after intravenous application of 2 micromol/kg NIR96010. Spectrometry showed an absorption maximum of the contrast agent at 755 nm. No spectral shifts occurred in protein-containing solution. Signal-to-noise ratio in the transmission intensity profiles ranged from 1.1 at 25 nmol/L contrast to 28 at 1 micromol/L. At concentrations <40 nmol/L, no differentiation from the background was possible. The transitional area between the contrast-free edge of the phantom and the central contrast-containing part appeared in the profiles as a steep increase with a width of 4.2 +/- 1.8 mm. The experimental tumors were detectable in nonenhanced images as well as contrast-enhanced images, with better delineation after contrast administration. In postcontrast absorption profiles, a 44.1% +/- 11.3% greater absorption increase was seen in tumor tissue compared with normal tissue. The laser wavelength lambda1 of the prototype laser mammography device was not situated at maximum absorption of the contrast agent NIR96010 but on the descending shoulder of the absorption spectrum. This implies a 20% signal loss for contrast detection. Despite the nonideal measurement conditions, concentrations as low as 40 nmol/L were detectable in vitro. In vivo, all tumors were detectable in color-coded nonenhanced scans as well as in contrast-enhanced scans, with better delineation after contrast administration.
Underwater electric field detection system based on weakly electric fish
NASA Astrophysics Data System (ADS)
Xue, Wei; Wang, Tianyu; Wang, Qi
2018-04-01
Weakly electric fish sense their surroundings in complete darkness by their active electric field detection system. However, due to the insufficient detection capacity of the electric field, the detection distance is not enough, and the detection accuracy is not high. In this paper, a method of underwater detection based on rotating current field theory is proposed to improve the performance of underwater electric field detection system. First of all, we built underwater detection system based on the theory of the spin current field mathematical model with the help of the results of previous researchers. Then we completed the principle prototype and finished the metal objects in the water environment detection experiments, laid the foundation for the further experiments.
Ultrasonic scanning system for in-place inspection of brazed-tube joints
NASA Technical Reports Server (NTRS)
Haralson, H. S.; Haynes, J. L.; Wages, C. G.
1971-01-01
System detects defects of .051 cm in diameter and larger. System incorporates scanning head assembly including boot enclosed transducer, slip ring assembly, drive mechanism, and servotransmitter. Ultrasonic flaw detector, prototype recorder, and special recorder complete system.
NASA Technical Reports Server (NTRS)
Eichenberg, Dennis J.; Lindamood, Glenn R.; Weiland, Karen J.; VanderWal, Randall L.
1999-01-01
The Mars Spark Source Prototype (MSSP) hardware has been developed as part of a proof of concept system for the detection of trace metals such as lead, cadmium, and arsenic in Martian dusts and soils. A spark discharge produces plasma from a soil sample and detectors measure the optical emission from metals in the plasma that will allow their identification and quantification. Trace metal measurements are vital for the assessment of the potential toxicity of the Martian environment for human exploration. The current method of X-ray fluorescence can yield concentrations only of major species. Other instruments are incompatible with the volume, weight, and power constraints for a Mars mission. The instrument will be developed primarily for use in the Martian environment, but would be adaptable for terrestrial use in environmental monitoring. This paper describes the Mars Spark Source Prototype hardware, the results of the characterization tests, and future plans for hardware development.
QPPM receiver for free-space laser communications
NASA Technical Reports Server (NTRS)
Budinger, J. M.; Mohamed, J. H.; Nagy, L. A.; Lizanich, P. J.; Mortensen, D. J.
1994-01-01
A prototype receiver developed at NASA Lewis Research Center for direct detection and demodulation of quaternary pulse position modulated (QPPM) optical carriers is described. The receiver enables dual-channel communications at 325-Megabits per second (Mbps) per channel. The optical components of the prototype receiver are briefly described. The electronic components, comprising the analog signal conditioning, slot clock recovery, matched filter and maximum likelihood data recovery circuits are described in more detail. A novel digital symbol clock recovery technique is presented as an alternative to conventional analog methods. Simulated link degradations including noise and pointing-error induced amplitude variations are applied. The bit-error-rate performance of the electronic portion of the prototype receiver under varying optical signal-to-noise power ratios is found to be within 1.5-dB of theory. Implementation of the receiver as a hybrid of analog and digital application specific integrated circuits is planned.
Advancing Technology for Starlight Suppression via an External Occulter
NASA Technical Reports Server (NTRS)
Kasdin, N. J.; Spergel, D. N.; Vanderbei, R. J.; Lisman, D.; Shaklan, S.; Thomson, M.; Walkemeyer, P.; Bach, V.; Oakes, E.; Cady, E.;
2011-01-01
External occulters provide the starlight suppression needed for detecting and characterizing exoplanets with a much simpler telescope and instrument than is required for the equivalent performing coronagraph. In this paper we describe progress on our Technology Development for Exoplanet Missions project to design, manufacture, and measure a prototype occulter petal. We focus on the key requirement of manufacturing a precision petal while controlling its shape within precise tolerances. The required tolerances are established by modeling the effect that various mechanical and thermal errors have on scatter in the telescope image plane and by suballocating the allowable contrast degradation between these error sources. We discuss the deployable starshade design, representative error budget, thermal analysis, and prototype manufacturing. We also present our meteorology system and methodology for verifying that the petal shape meets the contrast requirement. Finally, we summarize the progress to date building the prototype petal.
Hybrid integration of III-V and silicon materials and devices
NASA Astrophysics Data System (ADS)
Luo, Zhongsheng
Laser liftoff (LLO) based hybrid integration techniques including the double-transfer process and the pixel-to-point transfer process have been developed to integrate III-V photonics with silicon materials and circuitry. No degradation in the device performance has been observed using the LLO based transfer techniques. On the contrary, performance improvements in both electrical characteristics and electroluminescence (EL) output have been found for the (In,Ga)N light emitting diodes (LEDs) transferred onto Si substrate. Based on computer simulation, it is found that as much as 70% enhancement in EL output could be expected by optimizing the metal layering on the backside of the transferred LEDs. In order to understand the existing experimental data and improve controllability and damage-free transfer yield of the LLO process, a novel, comprehensive LLO model based on thermal-mechanical analysis has been proposed and developed. The LLO model has been validated in the well-studied GaN/sapphire system. By employing the LLO based transfer technique, two optoelectronic systems have been designed and demonstrated. The first one is an integrated fluorescence microsystem, which involved the integration of Cd(S,Se) bandgap filters, (In,Ga)N LEDs, Poly(dimethylsiloxane) (PDMS) microfluidic channels with a pre-fabricated Si PIN photodiode chip. Prototypes with both one color (blue LED) excitation and two-color (blue and green LED) excitation have consistently demonstrated a detection capability of as low as 1 nM fluosphere beads using Molecular Probes FluoSpheresRTM dye. Furthermore, the feasibility of multi-wavelength design has been verified using the bi-wavelength prototype. To optimize signal-to-noise ratio and detection sensitivity of the microsystem via system design, an in-depth mathematic analysis has also been performed. The second application is a zero-footprint optical metrology wafer, which relies on the reflection at the optical detection window, through which important parameters such as thickness, refractive index and density of the film on top of the detecting window can be probed in a real-time and location-specific manner. A novel methodology has been developed to ensure accurate and precise measurement across the wafer. A prototype wafer with 3x3 metrology cells has been prototyped and calibrated using a SF6 plasma etching process of silicon oxide.
Direct detection of a break in the teraelectronvolt cosmic-ray spectrum of electrons and positrons
NASA Astrophysics Data System (ADS)
DAMPE Collaboration; Ambrosi, G.; An, Q.; Asfandiyarov, R.; Azzarello, P.; Bernardini, P.; Bertucci, B.; Cai, M. S.; Chang, J.; Chen, D. Y.; Chen, H. F.; Chen, J. L.; Chen, W.; Cui, M. Y.; Cui, T. S.; D'Amone, A.; de Benedittis, A.; De Mitri, I.; di Santo, M.; Dong, J. N.; Dong, T. K.; Dong, Y. F.; Dong, Z. X.; Donvito, G.; Droz, D.; Duan, K. K.; Duan, J. L.; Duranti, M.; D'Urso, D.; Fan, R. R.; Fan, Y. Z.; Fang, F.; Feng, C. Q.; Feng, L.; Fusco, P.; Gallo, V.; Gan, F. J.; Gao, M.; Gao, S. S.; Gargano, F.; Garrappa, S.; Gong, K.; Gong, Y. Z.; Guo, D. Y.; Guo, J. H.; Hu, Y. M.; Huang, G. S.; Huang, Y. Y.; Ionica, M.; Jiang, D.; Jiang, W.; Jin, X.; Kong, J.; Lei, S. J.; Li, S.; Li, X.; Li, W. L.; Li, Y.; Liang, Y. F.; Liang, Y. M.; Liao, N. H.; Liu, H.; Liu, J.; Liu, S. B.; Liu, W. Q.; Liu, Y.; Loparco, F.; Ma, M.; Ma, P. X.; Ma, S. Y.; Ma, T.; Ma, X. Q.; Ma, X. Y.; Marsella, G.; Mazziotta, M. N.; Mo, D.; Niu, X. Y.; Peng, X. Y.; Peng, W. X.; Qiao, R.; Rao, J. N.; Salinas, M. M.; Shang, G. Z.; H. Shen, W.; Shen, Z. Q.; Shen, Z. T.; Song, J. X.; Su, H.; Su, M.; Sun, Z. Y.; Surdo, A.; Teng, X. J.; Tian, X. B.; Tykhonov, A.; Vagelli, V.; Vitillo, S.; Wang, C.; Wang, H.; Wang, H. Y.; Wang, J. Z.; Wang, L. G.; Wang, Q.; Wang, S.; Wang, X. H.; Wang, X. L.; Wang, Y. F.; Wang, Y. P.; Wang, Y. Z.; Wen, S. C.; Wang, Z. M.; Wei, D. M.; Wei, J. J.; Wei, Y. F.; Wu, D.; Wu, J.; Wu, L. B.; Wu, S. S.; Wu, X.; Xi, K.; Xia, Z. Q.; Xin, Y. L.; Xu, H. T.; Xu, Z. L.; Xu, Z. Z.; Xue, G. F.; Yang, H. B.; Yang, P.; Yang, Y. Q.; Yang, Z. L.; Yao, H. J.; Yu, Y. H.; Yuan, Q.; Yue, C.; Zang, J. J.; Zhang, C.; Zhang, D. L.; Zhang, F.; Zhang, J. B.; Zhang, J. Y.; Zhang, J. Z.; Zhang, L.; Zhang, P. F.; Zhang, S. X.; Zhang, W. Z.; Zhang, Y.; Zhang, Y. J.; Zhang, Y. Q.; Zhang, Y. L.; Zhang, Y. P.; Zhang, Z.; Zhang, Z. Y.; Zhao, H.; Zhao, H. Y.; Zhao, X. F.; Zhou, C. Y.; Zhou, Y.; Zhu, X.; Zhu, Y.; Zimmer, S.
2017-12-01
High-energy cosmic-ray electrons and positrons (CREs), which lose energy quickly during their propagation, provide a probe of Galactic high-energy processes and may enable the observation of phenomena such as dark-matter particle annihilation or decay. The CRE spectrum has been measured directly up to approximately 2 teraelectronvolts in previous balloon- or space-borne experiments, and indirectly up to approximately 5 teraelectronvolts using ground-based Cherenkov γ-ray telescope arrays. Evidence for a spectral break in the teraelectronvolt energy range has been provided by indirect measurements, although the results were qualified by sizeable systematic uncertainties. Here we report a direct measurement of CREs in the energy range 25 gigaelectronvolts to 4.6 teraelectronvolts by the Dark Matter Particle Explorer (DAMPE) with unprecedentedly high energy resolution and low background. The largest part of the spectrum can be well fitted by a ‘smoothly broken power-law’ model rather than a single power-law model. The direct detection of a spectral break at about 0.9 teraelectronvolts confirms the evidence found by previous indirect measurements, clarifies the behaviour of the CRE spectrum at energies above 1 teraelectronvolt and sheds light on the physical origin of the sub-teraelectronvolt CREs.
Dark forces in the sky: signals from Z{sup ′} and the dark Higgs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bell, Nicole F.; Cai, Yi; Leane, Rebecca K.
2016-08-01
We consider the indirect detection signals for a self-consistent hidden U(1) model containing a Majorana dark matter candidate, χ, a dark gauge boson, Z{sup ′}, and a dark Higgs, s. Compared with a model containing only a dark matter candidate and Z{sup ′} mediator, the addition of the scalar provides a mass generation mechanism for the dark sector particles and is required in order to avoid unitarity violation at high energies. We find that the inclusion of the two mediators opens up a new two-body s-wave annihilation channel, χχ→sZ{sup ′}. This new process, which is missed in the usual single-mediatormore » simplified model approach, can be the dominant annihilation channel. This provides rich phenomenology for indirect detection searches, allows indirect searches to explore regions of parameter space not accessible with other commonly considered s-wave annihilation processes, and enables both the Z{sup ′} and scalar couplings to be probed. We examine the phenomenology of the sector with a focus on this new process, and determine the limits on the model parameter space from Fermi data on dwarf spheriodal galaxies and other relevant experiments.« less
NASA Astrophysics Data System (ADS)
Shen, Ming; Trébosc, Julien; O'Dell, Luke A.; Lafon, Olivier; Pourpoint, Frédérique; Hu, Bingwen; Chen, Qun; Amoureux, Jean-Paul
2015-09-01
We present an experimental comparison of several through-space Hetero-nuclear Multiple-Quantum Correlation experiments, which allow the indirect observation of homo-nuclear single- (SQ) or double-quantum (DQ) 14N coherences via spy 1H nuclei. These 1H-{14N} D-HMQC sequences differ not only by the order of 14N coherences evolving during the indirect evolution, t1, but also by the radio-frequency (rf) scheme used to excite and reconvert these coherences under Magic-Angle Spinning (MAS). Here, the SQ coherences are created by the application of center-band frequency-selective pulses, i.e. long and low-power rectangular pulses at the 14N Larmor frequency, ν0(14N), whereas the DQ coherences are excited and reconverted using rf irradiation either at ν0(14N) or at the 14N overtone frequency, 2ν0(14N). The overtone excitation is achieved either by constant frequency rectangular pulses or by frequency-swept pulses, specifically Wide-band, Uniform-Rate, and Smooth-Truncation (WURST) pulse shapes. The present article compares the performances of four different 1H-{14N} D-HMQC sequences, including those with 14N rectangular pulses at ν0(14N) for the indirect detection of homo-nuclear (i) 14N SQ or (ii) DQ coherences, as well as their overtone variants using (iii) rectangular or (iv) WURST pulses. The compared properties include: (i) the sensitivity, (ii) the spectral resolution in the 14N dimension, (iii) the rf requirements (power and pulse length), as well as the robustness to (iv) rf offset and (v) MAS frequency instabilities. Such experimental comparisons are carried out for γ-glycine and L-histidine.HCl monohydrate, which contain 14N sites subject to moderate quadrupole interactions. We demonstrate that the optimum choice of the 1H-{14N} D-HMQC method depends on the experimental goal. When the sensitivity and/or the robustness to offset are the major concerns, the D-HMQC sequence allowing the indirect detection of 14N SQ coherences should be employed. Conversely, when the highest resolution and/or adjusted indirect spectral width are needed, overtone experiments are the method of choice. The overtone scheme using WURST pulses results in broader excitation bandwidths than that using rectangular pulses, at the expense of reduced sensitivity. Numerically exact simulations also show that the sensitivity of the overtone 1H-{14N} D-HMQC experiment increases for larger quadrupole interactions.
NASA Astrophysics Data System (ADS)
Zhang, Wen-Shuai; Cai, Hong-Bo; Shan, Lian-Qiang; Zhang, Hua-Sen; Gu, Yu-Qiu; Zhu, Shao-Ping
2017-06-01
Observations of anomalous neutron yield in the indirect-drive inertial confinement fusion implosion experiments conducted at SG-III prototype and SG-II upgrade laser facilities are interpreted. The anomalous mechanism results in a neutron yield which is 100-times higher than that predicted by 1D radiation-hydrodynamic simulations. 2D radiation-hydrodynamic simulations show that the supersonic, radially directed gold (Au) plasma jets arising from the laser-hohlraum interactions can collide with the carbon-deuterium (CD) corona plasma of the compressed pellet. It is found that in the interaction front of the high-Z jet with the low-Z corona, with low density ˜{{10}20}~\\text{c}{{\\text{m}}-3} and high temperature ˜keV, kinetic effects become important. Particle-in-cell simulations indicate that an electrostatic shock wave can be driven when the high-temperature Au jet expands into the low-temperature CD corona. Deuterium ions with an amount of ˜1015 can be accelerated to ˜25 keV by the collisionless shock wave, thus causing efficient neutron productions though the beam-target method by stopping these energetic ions in the corona. The evaluated neutron yield is consistent with the experiments conducted at SG laser facilities.
France, Logan K; Vermillion, Meghan S; Garrett, Caroline M
2018-01-01
Blood pressure is a critical parameter for evaluating cardiovascular health, assessing effects of drugs and procedures, monitoring physiologic status during anesthesia, and making clinical decisions. The placement of an arterial catheter is the most direct and accurate method for measuring blood pressure; however, this approach is invasive and of limited use during brief sedated examinations. The objective of this study was to determine which method of indirect blood pressure monitoring was most accurate compared with measurement by direct arterial catheterization. In addition, we sought to determine the relative accuracy of each indirect method (compared with direct arterial measurement) at a given body location and to assess whether the accuracy of each indirect method was dependent on body location. We compared direct blood pressure measurements by means of catheterization of the saphenous artery with oscillometric and ultrasonic Doppler flow detection measurements at 3 body locations (forearm, distal leg, and tail base) in 16 anesthetized, male rhesus macaques. The results indicate that oscillometry at the forearm is the best indirect method and location for accurately and consistently measuring blood pressure in healthy male rhesus macaques.
Moser, Harald; Pölz, Walter; Waclawek, Johannes Paul; Ofner, Johannes; Lendl, Bernhard
2017-01-01
The implementation of a sensitive and selective as well as industrial fit gas sensor prototype based on wavelength modulation spectroscopy with second harmonic detection (2f-WMS) employing an 8-μm continuous-wave distributed feedback quantum cascade laser (CW-DFB-QCL) for monitoring hydrogen sulfide (H 2 S) at sub-ppm levels is reported. Regarding the applicability for analytical and industrial process purposes aimed at petrochemical environments, a synthetic methane (CH 4 ) matrix of up to 1000 ppmv together with a varying H 2 S content was chosen as the model environment for the laboratory-based performance evaluation performed at TU Wien. A noise-equivalent absorption sensitivity (NEAS) for H 2 S targeting the absorption line at 1247.2 cm -1 was found to be 8.419 × 10 -10 cm -1 Hz -1/2 , and a limit of detection (LOD) of 150 ppbv H 2 S could be achieved. The sensor prototype was then deployed for on-site measurements at the petrochemical research hydrogenation platform of the industrial partner OMV AG. In order to meet the company's on-site safety regulations, the H 2 S sensor platform was installed in an industry rack and equipped with the required safety infrastructure for protected operation in hazardous and explosive environments. The work reports the suitability of the sensor prototype for simultaneous monitoring of H 2 S and CH 4 content in the process streams of a research hydrodesulfurization (HDS) unit. Concentration readings were obtained every 15 s and revealed process dynamics not observed previously.
Integration of the TDWR and LLWAS wind shear detection system
NASA Technical Reports Server (NTRS)
Cornman, Larry
1991-01-01
Operational demonstrations of a prototype TDWR/LLWAS (Terminal Doppler Weather Radar/Low Level Wind shear Alarm System) integrated wind shear detection system were conducted. The integration of wind shear detection systems is needed to provide end-users with a single, consensus source of information. A properly implemented integrated system provides wind shear warnings of a higher quality than stand-alone LLWAS or TDWR systems. The algorithmic concept used to generate the TDWR/LLWAS integrated products and several case studies are discussed, indicating the viability and potential of integrated wind shear detection systems. Implications for integrating ground and airborne wind shear detection systems are briefly examined.
Lu, Shi-Ying; Zhou, Yu; Li, Yan-Song; Lin, Chao; Meng, Xian-Mei; Yan, Dong-Ming; Li, Zhao-Hui; Yu, Shi-Yu; Liu, Zeng-Shan; Ren, Hong-Lin
2011-08-01
Okadaic acid (OA) and analogues of dinophysistoxin (DTX) are key diarrheic shellfish poisoning (DSP) toxins, which possibly arouse DSP symptoms by consuming the contaminated shellfish. Because of the stable toxicity in high temperature and the long-term carcinogenicity, the outbreaks of DSP related to consumption of bivalve mollusks contaminated by DSP toxins pose a hazard to public health. Therefore, it is worth developing a fast and reliable analytical method for the detection of OA and analogues in shellfish. In this paper, an indirect competitive enzyme-linked immunosorbent assay (ELISA) (icELISA) for detecting OA and DTX-1 in seafood was developed based on monoclonal antibody (McAb). The OA was conjugated to human immunoglobulin G (IgG) and bovine serum albumin (BSA) by the active ester method as the immune antigen and the detective antigen. The spleen cells from BALB/c mice immunized with OA-IgG were fused with SP2/0 myeloma cells. A hybridoma cell line, which secreted McAb against OA, was selected by "limiting dilution" cloning. An icELISA was developed based on immobilized conjugate (OA-BSA) competing the McAb with the free OA in seafood sample. A hybridoma cell line, which secreted IgG1 subclass monoclonal antibody (McAb) against OA, was selected. The IC(50) of the McAb for OA and dinophytoxin-1 (DTX-1) were 4.40 and 3.89 ng/mL, respectively. Based on the McAb, an indirect competitive ELISA for detection of OA and DTX-1 in seafood was developed. The regression equation was y = 54.713x - 25.879 with a coefficient correlation of R (2) = 0.9729. The linear range and the limit of detection were 0.4-12.5 and 0.45 ng/mL, respectively. The average recovery of OA and DTX-1 spiked shellfish was 82.29% with the coefficient of variation of 7.67%. The developed icELISA is a fast, sensitive, and convenient assay for detecting of total amount of OA and DTX-1 in seafood.
Source detection at 100 meter standoff with a time-encoded imaging system
NASA Astrophysics Data System (ADS)
Brennan, J.; Brubaker, E.; Gerling, M.; Marleau, P.; Monterial, M.; Nowack, A.; Schuster, P.; Sturm, B.; Sweany, M.
2018-01-01
We present the design, characterization, and testing of a laboratory prototype radiological search and localization system. The system, based on time-encoded imaging, uses the attenuation signature of neutrons in time, induced by the geometrical layout and motion of the system. We have demonstrated the ability to detect a ∼ 1mCi252Cf radiological source at 100m standoff with 90% detection efficiency and 10% false positives against background in 12min. This same detection efficiency is met at 15s for a 40m standoff, and 1 . 2s for a 20m standoff.
Study to develop improved methods to detect leakage in fluid systems, phase 2
NASA Technical Reports Server (NTRS)
Janus, J. C.; Cimerman, I.
1971-01-01
An ultrasonic contact sensor engineering prototype leak detection system was developed and its capabilities under cryogenic operations demonstrated. The results from tests indicate that the transducer performed well on liquid hydrogen plumbing, that flow and valve actuation could be monitored, and that the phase change from gaseous to liquid hydrogen could be detected by the externally mounted transducers. Tests also demonstrate the ability of the system to detect internal leaks past valve seats and to function as a flow meter. Such a system demonstrates that it is not necessary to break into welded systems to locate internal leaks.
Object Detection using the Kinect
2012-03-01
Kinect camera and point cloud data from the Kinect’s structured light stereo system (figure 1). We obtain reasonable results using a single prototype...same manner we present in this report. For example, at Willow Garage , Steder uses a 3-D feature he developed to classify objects directly from point...detecting backpacks using the data available from the Kinect sensor. 4 3.1 Point Cloud Filtering Dense point clouds derived from stereo are notoriously
Explosives detection in the marine environment using UUV-modified immunosensor
NASA Astrophysics Data System (ADS)
Charles, Paul T.; Adams, André A.; Deschamps, Jeffrey R.; Veitch, Scott P.; Hanson, Alfred; Kusterbeck, Anne W.
2011-05-01
Port and harbor security has rapidly become a point of interest and concern with the emergence of new improvised explosive devices (IEDs). The ability to provide physical surveillance and identification of IEDs and unexploded ordnances (UXO) at these entry points has led to an increased effort in the development of unmanned underwater vehicles (UUVs) equipped with sensing devices. Traditional sensors used to identify and locate potential threats are side scan sonar/acoustic methods and magnetometers. At the Naval Research Laboratory (NRL), we have developed an immunosensor capable of detecting trace levels of explosives that has been integrated into a REMUS payload for use in the marine environment. Laboratory tests using a modified PMMA microfluidic device with immobilized monoclonal antibodies specific for TNT and RDX have been conducted yielding detection levels in the low parts-per-billion (ppb) range. New designs and engineered improvements in microfluidic devices, fluorescence signal probes, and UUV internal fluidic and optical components have been investigated and integrated into the unmanned underwater prototype. Results from laboratory and recent field demonstrations using the prototype UUV immunosensor will be discussed. The immunosensor in combination with acoustic and other sensors could serve as a complementary characterization tool for the detection of IEDs, UXOs and other potential chemical or biological threats.
Severns, Virginia; Branch, Darren W.; Edwards, Thayne L.; Larson, Richard S.
2013-01-01
Disasters can create situations in which blood donations can save lives. However, in emergency situations and when resources are depleted, on-site blood donations require the rapid and accurate detection of blood-borne pathogens, including human immunodeficiency virus types 1 and 2 (HIV-1 and HIV-2). Techniques such as PCR and antibody capture by an enzyme-linked immunosorbent assay (ELISA) for HIV-1 and HIV-2 are precise but time-consuming and require sophisticated equipment that is not compatible with emergency point-of-care requirements. We describe here a prototype biosensor based on piezoelectric materials functionalized with specific antibodies against HIV-1 and HIV-2. We show the rapid and accurate detection of HIV-1 and HIV-2 in both simple and complex solutions, including human serum, and in the presence of a cross-confounding virus. We report detection limits of 12 50% tissue culture infective doses (TCID50s) for HIV-1 and 87 TCID50s for HIV-2. The accuracy, precision of measurements, and operation of the prototype biosensor compared favorably to those for nucleic acid amplification. We conclude that the biosensor has significant promise as a successful point-of-care diagnostic device for use in emergency field applications requiring rapid and reliable testing for blood-borne pathogens. PMID:23515541
Real Time Intelligent Target Detection and Analysis with Machine Vision
NASA Technical Reports Server (NTRS)
Howard, Ayanna; Padgett, Curtis; Brown, Kenneth
2000-01-01
We present an algorithm for detecting a specified set of targets for an Automatic Target Recognition (ATR) application. ATR involves processing images for detecting, classifying, and tracking targets embedded in a background scene. We address the problem of discriminating between targets and nontarget objects in a scene by evaluating 40x40 image blocks belonging to an image. Each image block is first projected onto a set of templates specifically designed to separate images of targets embedded in a typical background scene from those background images without targets. These filters are found using directed principal component analysis which maximally separates the two groups. The projected images are then clustered into one of n classes based on a minimum distance to a set of n cluster prototypes. These cluster prototypes have previously been identified using a modified clustering algorithm based on prior sensed data. Each projected image pattern is then fed into the associated cluster's trained neural network for classification. A detailed description of our algorithm will be given in this paper. We outline our methodology for designing the templates, describe our modified clustering algorithm, and provide details on the neural network classifiers. Evaluation of the overall algorithm demonstrates that our detection rates approach 96% with a false positive rate of less than 0.03%.
DOT National Transportation Integrated Search
2002-01-01
To address the problem of safely and quantifiably detecting corrosion in a cost-effective and timely manner, the University of Virginia and Virginia Technologies, Inc. have developed a remotely accessible, networked, embedded corrosion instrument. Th...
Wang, G; Ding, J; Hu, S; Yang, X
2012-10-01
Fragment of 759 bp DNA spanning the Matrix 1 (M1) gene of Avian Influenza Virus (AIV) was inserted into an expression vector pET28c to construct a recombinant plasmid pET28c-M1. The pET28c-M1 plasmid was transformed into the Escherichia coli BL21 (DE3) competent cell to produce a recombinant strain E. coli 21 (DE3). After being induced by Isopropyl-b-D-galactopyranoside (IPTG), E. coli 21 (DE3) expressed a 28-kDa fusion protein at a high level. This protein can bind anti-AIV (H5N1) positive serum by Western-blot analysis. After being denatured, renatured, and purified by Ni(2+)-column, the fusion protein was used as an antigen to develop Matrix 1 Enzyme-Linked Immunosorbent Assay (M1-ELISA) for detecting antibodies against AIV from chicken serum. We found that this indirect M1-ELISA was sensitive for differentiating antisera against AIV and antisera against other six kinds of avian viruses apart from AIV and this method is more sensitive than Hemagglutination Inhibition (HI) test. When compared with HI test and ELISA (IDEXX) in evaluating 581 serum samples from field vaccinated chickens, this assay showed 93.3% agreement ratio with the HI test, as well as 96.0% agreement ratio with ELISA (IDEXX). In a preliminary application, the assay successfully detected 19 AIVs from 51 nonvaccinated chicken lungs. It concludes that an indirect ELISA was successfully developed for detecting AIV. The assay is specific and sensitive. The application will greatly contribute to the long-term prevention and control of avian influenza in China. Copyright © 2011 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeff Aron; Jeff Jia; Bruce Vance
2005-02-01
This report describes prototypes, measurements, and results for a project to develop a prototype pipeline in-line inspection (ILI) tool that uses electromagnetic acoustic transducers (EMATs) to detect and grade stress corrosion cracking (SCC). The introduction briefly provides motivation and describes SCC, gives some background on EMATs and guided ultrasonic waves, and reviews promising results of a previous project using EMATs for SCC. The experimental section then describes lab measurement techniques and equipment, the lab mouse and prototypes for a mule, and scan measurements made on SCC. The mouse was a moveable and compact EMAT setup. The prototypes were even moremore » compact circuits intended to be pulled or used in an ILI tool. The purpose of the measurements was to determine the best modes, transduction, and processing to use, to characterize the transducers, and to prove EMATs and mule components could produce useful results. Next, the results section summarizes the measurements and describes the mouse scans, processing, prototype circuit operating parameters, and performance for SH0 scans. Results are given in terms of specifications--like SNR, power, insertion loss--and parametric curves--such as signal amplitude versus magnetic bias or standoff, reflection or transmission coefficients versus crack depth. Initially, lab results indicated magnetostrictive transducers using both SH0 and SV1 modes would be worthwhile to pursue in a practical ILI system. However, work with mule components showed that SV1 would be too dispersive, so SV1 was abandoned. The results showed that reflection measurements, when normalized by the direct arrival are sensitive to and correlated with SCC. This was not true for transmission measurements. Processing yields a high data reduction, almost 60 to 1, and permits A and C scan display techniques and software already in use for pipeline inspection. An analysis of actual SH0 scan results for SCC of known dimensions showed that length and depth could be determined for deep enough cracks. Defect shadow and short length effects were apparent but may be taken into account. The SH0 scan was done with the mule prototype circuits and permanent magnet EMATs. These gave good enough results that this hardware and the processing techniques are very encouraging for use in a practical ILI tool.« less
NASA Astrophysics Data System (ADS)
la Grone, Marcus J.; Cumming, Colin J.; Fisher, Mark E.; Fox, Michael J.; Jacob, Sheena; Reust, Dennis; Rockley, Mark G.; Towers, Eric
2000-08-01
The explosive charge within a landmine is the source for a mixture of chemical vapors that form a distinctive 'chemical signature' indicative of a landmine. The concentration of these compounds in the air over landmines is extremely low, well below the minimum detection limits of most field- portable chemical sensors. Described in this paper is a man- portable landmine detection system that has for the first time demonstrated the ability to detect landmines by direct sensing of the vapors of signature compounds in the air over landmines. The system utilizes fluorescent polymers developed by collaborators at the MIT. The sensor can detect ultra-trace concentrations of TNT vapor and other nitroaromatic compounds found in many landmine explosives. Thin films of the polymers exhibit intense fluorescence, but when exposed to vapors of nitroaromatic explosives the intensity of the light emitted from the films decreases. A single molecule of TNT binding to a receptor site quenches the fluorescence from many polymer repeat units, increasing the sensitivity by orders of magnitude. A sensor prototype has been develop that response in near real-time to low femtogram quantities of nitroaromatic explosives. The prototype is portable, lightweight, has low power consumption, is simple to operate, and is relatively inexpensive. Simultaneous field testing of the sensor and experienced canine landmine detection teams was recently completed. Although the testing was limited in scope, the performance of the senor met or exceeded that of the canines against buried landmines.
Detection of direct and indirect noise generated by synthetic hot spots in a duct
NASA Astrophysics Data System (ADS)
De Domenico, Francesca; Rolland, Erwan O.; Hochgreb, Simone
2017-04-01
Sound waves in a combustor are generated from fluctuations in the heat release rate (direct noise) or the acceleration of entropy, vorticity or compositional perturbations through nozzles or turbine guide vanes (indirect or entropy noise). These sound waves are transmitted downstream as well as reflected upstream of the acceleration point, contributing to the overall noise emissions, or triggering combustion instabilities. Previous experiments attempted to isolate indirect noise by generating thermoacoustic hot spots electrically and measuring the transmitted acoustic waves, yet there are no measurements on the backward propagating entropy and acoustic waves. This work presents the first measurements which clearly separate the direct and indirect noise contributions to pressure fluctuations upstream of the acceleration point. Synthetic entropy spots are produced by unsteady electrical heating of a grid of thin wires located in a tube. Compression waves (direct noise) are generated from this heating process. The hot spots are then advected with the mean flow and finally accelerated through an orifice plate located at the end of the tube, producing a strong acoustic signature which propagates upstream (indirect noise). The convective time is selected to be longer than the heating pulse length, in order to obtain a clear time separation between direct and indirect noise in the overall pressure trace. The contribution of indirect noise to the overall noise is shown to be non-negligible either in subsonic or sonic throat conditions. However, the absolute amplitude of direct noise is larger than the corresponding fraction of indirect noise, explaining the difficulty in clearly identifying the two contributions when they are merged. Further, the work shows the importance of using appropriate pressure transducer instrumentation and correcting for the respective transfer functions in order to account for low frequency effects in the determination of pressure fluctuations.
USDA-ARS?s Scientific Manuscript database
Background: Cattle persistently infected with Babesia bovis are reservoirs for intra- and inter-herd transmission. Since B. bovis is considered a persistent infection, developing a reliable, high-throughput assay that detects antibody during all stages of the infection could be pivotal for establish...
MSSM A-funnel and the galactic center excess: prospects for the LHC and direct detection experiments
Freese, Katherine; López, Alejandro; Shah, Nausheen R.; ...
2016-04-11
The pseudoscalar resonance or “A-funnel” in the Minimal Supersymmetric Standard Model (MSSM) is a widely studied framework for explaining dark matter that can yield interesting indirect detection and collider signals. The well-known Galactic Center excess (GCE) at GeV energies in the gamma ray spectrum, consistent with annihilation of a ≲ 40 GeV dark matter particle, has more recently been shown to be compatible with significantly heavier masses following reanalysis of the background.For this study, we explore the LHC and direct detection implications of interpreting the GCE in this extended mass window within the MSSM A-funnel framework. We find that compatibilitymore » with relic density, signal strength, collider constraints, and Higgs data can be simultaneously achieved with appropriate parameter choices. The compatible regions give very sharp predictions of 200-600 GeV CP-odd/even Higgs bosons at low tan β at the LHC and spin-independent cross sections ≈ 10 -11 pb at direct detection experiments. Finally, regardless of consistency with the GCE, this study serves as a useful template of the strong correlations between indirect, direct, and LHC signatures of the MSSM A-funnel region.« less
NASA Astrophysics Data System (ADS)
Golnik, C.; Bemmerer, D.; Enghardt, W.; Fiedler, F.; Hueso-González, F.; Pausch, G.; Römer, K.; Rohling, H.; Schöne, S.; Wagner, L.; Kormoll, T.
2016-06-01
The finite range of a proton beam in tissue opens new vistas for the delivery of a highly conformal dose distribution in radiotherapy. However, the actual particle range, and therefore the accurate dose deposition, is sensitive to the tissue composition in the proton path. Range uncertainties, resulting from limited knowledge of this tissue composition or positioning errors, are accounted for in the form of safety margins. Thus, the unverified particle range constrains the principle benefit of proton therapy. Detecting prompt γ-rays, a side product of proton-tissue interaction, aims at an on-line and non-invasive monitoring of the particle range, and therefore towards exploiting the potential of proton therapy. Compton imaging of the spatial prompt γ-ray emission is a promising measurement approach. Prompt γ-rays exhibit emission energies of several MeV. Hence, common radioactive sources cannot provide the energy range a prompt γ-ray imaging device must be designed for. In this work a benchmark measurement-setup for the production of a localized, monoenergetic 4.44 MeV γ-ray source is introduced. At the Tandetron accelerator at the HZDR, the proton-capture resonance reaction 15N(p,α γ4.439)12C is utilized. This reaction provides the same nuclear de-excitation (and γ-ray emission) occurrent as an intense prompt γ-ray line in proton therapy. The emission yield is quantitatively described. A two-stage Compton imaging device, dedicated for prompt γ-ray imaging, is tested at the setup exemplarily. Besides successful imaging tests, the detection efficiency of the prototype at 4.44 MeV is derived from the measured data. Combining this efficiency with the emission yield for prompt γ-rays, the number of valid Compton events, induced by γ-rays in the energy region around 4.44 MeV, is estimated for the prototype being implemented in a therapeutic treatment scenario. As a consequence, the detection efficiency turns out to be a key parameter for prompt γ-rays Compton imaging limiting the applicability of the prototype in its current realization.
Development of a prototype for dissolved CO2 rapid measurement and preliminary tests
NASA Astrophysics Data System (ADS)
Li, Meng; Guo, Jinjia; Zhang, Zhihao; Luo, Zhao; Qin, Chuan; Zheng, Ronger
2017-10-01
The measurements of dissolved CO2 in seawater is of great significance for the study of global carbon cycle. At present, the commercial sensors used for dissolved CO2 measurements are mostly equipped with permeable membranes for the purpose of gas-liquid separation, with the advantages of easy operation, low cost, etc.. However, most of these devices measure CO2 after reaching gas equilibrium, so it takes a few minutes to respond, which limited its applications in rapid measurements. In this paper, a set of prototype was developed for the rapid measurements of dissolved CO2. The system was built basing the direct absorption TDLAS. To detect the CO2 absorption line located at 4991.26 cm-1 , a fiber-coupled DFB laser operating at 2004 nm was selected as the light source. A Herriott type multi-pass cavity with an effective optical path length of 10 m and an inner volume of 90 mL was used for absorption measurements. A detection limit of 26 μatm can be obtained with this compact cavity. To realize the rapid measurements of dissolved CO2, a degasser with high degassing rate was necessary. A hollow fiber membrane with a large permeable area used in this paper can achieve degassing rate up to 2.88 kPa/min. Benefitted from the high degassing rate of the degasser and high sensitivity of the compact TDLAS system, a rapid measurement of dissolved CO2 in water can be achieved within 1s time, and the response time of the prototype when the dissolved CO2 concentration changed abruptly in actual measurement was 15 s. To evaluate the performance of the prototype, comparison measurements were carried out with a commercial mass spectrometer. The dissolved CO2 in both seawater and tap-water was measured, and the experimental results showed good consistent trends with R2 of 0.973 and 0.931. The experimental results proved the feasibility of dissolved CO2 rapid measurement. In the near future, more system evaluation experiments will be carried out and the system will be further optimized focusing on the underwater in-situ detection system.
A Prototype of Reflection Pulse Oximeter Designed for Mobile Healthcare.
Lu, Zhiyuan; Chen, Xiang; Dong, Zhongfei; Zhao, Zhangyan; Zhang, Xu
2016-09-01
This paper introduces a pulse oximeter prototype designed for mobile healthcare. In this prototype, a reflection pulse oximeter is embedded into the back cover of a smart handheld device to offer the convenient measurement of both heart rate (HR) and SpO2 (estimation of arterial oxygen saturation) for home or mobile applications. Novel and miniaturized circuit modules including a chopper network and a filtering amplifier were designed to overcome the influence of ambient light and interferences that are caused by embedding the sensor into a flat cover. A method based on adaptive trough detection for improved HR and SpO2 estimation is proposed with appropriate simplification for its implementation on mobile devices. A fast and effective photoplethysmogram validation scheme is also proposed. Clinical experiments have been carried out to calibrate and test our oximeter. Our prototype oximeter can achieve comparable performance to a clinical oximeter with no significant difference revealed by paired t -tests ( p = 0.182 for SpO2 measurement and p = 0.496 for HR measurement). The design of this pulse oximeter will facilitate fast and convenient measurement of SpO2 for mobile healthcare.
Inauguration and first light of the GCT-M prototype for the Cherenkov telescope array
NASA Astrophysics Data System (ADS)
Watson, J. J.; De Franco, A.; Abchiche, A.; Allan, D.; Amans, J.-P.; Armstrong, T. P.; Balzer, A.; Berge, D.; Boisson, C.; Bousquet, J.-J.; Brown, A. M.; Bryan, M.; Buchholtz, G.; Chadwick, P. M.; Costantini, H.; Cotter, G.; Daniel, M. K.; De Frondat, F.; Dournaux, J.-L.; Dumas, D.; Ernenwein, J.-P.; Fasola, G.; Funk, S.; Gironnet, J.; Graham, J. A.; Greenshaw, T.; Hervet, O.; Hidaka, N.; Hinton, J. A.; Huet, J.-M.; Jegouzo, I.; Jogler, T.; Kraus, M.; Lapington, J. S.; Laporte, P.; Lefaucheur, J.; Markoff, S.; Melse, T.; Mohrmann, L.; Molyneux, P.; Nolan, S. J.; Okumura, A.; Osborne, J. P.; Parsons, R. D.; Rosen, S.; Ross, D.; Rowell, G.; Rulten, C. B.; Sato, Y.; Sayède, F.; Schmoll, J.; Schoorlemmer, H.; Servillat, M.; Sol, H.; Stamatescu, V.; Stephan, M.; Stuik, R.; Sykes, J.; Tajima, H.; Thornhill, J.; Tibaldo, L.; Trichard, C.; Vink, J.; White, R.; Yamane, N.; Zech, A.; Zink, A.; Zorn, J.; CTA Consortium
2017-01-01
The Gamma-ray Cherenkov Telescope (GCT) is a candidate for the Small Size Telescopes (SSTs) of the Cherenkov Telescope Array (CTA). Its purpose is to extend the sensitivity of CTA to gamma-ray energies reaching 300 TeV. Its dual-mirror optical design and curved focal plane enables the use of a compact camera of 0.4 m diameter, while achieving a field of view of above 8 degrees. Through the use of the digitising TARGET ASICs, the Cherenkov flash is sampled once per nanosecond contin-uously and then digitised when triggering conditions are met within the analogue outputs of the photosensors. Entire waveforms (typically covering 96 ns) for all 2048 pixels are then stored for analysis, allowing for a broad spectrum of investigations to be performed on the data. Two prototypes of the GCT camera are under development, with differing photosensors: Multi-Anode Photomultipliers (MAPMs) and Silicon Photomultipliers (SiPMs). During November 2015, the GCT MAPM (GCT-M) prototype camera was integrated onto the GCT structure at the Observatoire de Paris-Meudon, where it observed the first Cherenkov light detected by a prototype instrument for CTA.
Treatment of Oroantral Communication Using the Lateral Palatal Sliding Flap Technique
Ribeiro, Fernando Salimon; de Toledo, Cassio Torres; Aleixo, Michele Romero; Durigan, Maria Cristina; da Silva, Willian Corrêa; Bueno, Samanta Kelen; Pontes, Ana Emília Farias
2015-01-01
Herein, we present a case of oroantral communication that was to be treated with clinical examination, tomography, and prototyping. A patient presented with oroantral communication with purulent exudation for 4 months, since the displacement of the dental implant and O-ring component to the maxillary sinus. Tomographic examination and prototyping revealed a 5 mm bone gap. The patient underwent local washes and antibiotic therapy. After local palpation, a bone defect detected by prototyping was suspected to be greater than that observed. For the surgery, a communication tunnel was made, and the bone defect was found to be 12 mm in diameter. A pedicle flap was raised on the palate, followed by sliding and suturing. No complications were observed during the postoperative period, and the suture was removed after a week. Four months later, communication did not resume, and the patient did not complain of pain, foul smelling, or purulent discharge and was satisfied with the outcome. The findings of this case suggest that the lateral sliding flap can be used as an efficient technique for closing oroantral communications. An accurate clinical examination is a critical tool that can be used instead of tomography and prototyping, which can be misleading. PMID:26113864
Panek, Paul; Fazekas, Gabor; Lüftenegger, Theresa; Mayer, Peter; Pilissy, Tamas; Raffaelli, Matteo; Rist, Atilla; Rosenthal, Ramona; Savanovic, Arso; Sobjak, Anna; Sonntag, Franziska; Toth, Andras; Unger, Birgit
2017-01-01
Standard toilets often do not meet the needs of a significant number of older persons and persons with disabilities. The EU funded iToilet project aims at design and development of a new type of ICT enhanced modular toilet system which shall be able to support autonomy, dignity and safety of older persons living at home. Methodologically the project started with gathering user requirements by means of questionnaires, interviews and focus group discussion involving a total of 74 persons, thereof 41 subjects with movement disorders (primary users), 21 caregivers (secondary users) and 12 healthcare managers (tertiary users). Most important wishes were bilateral removable handrails, height and tilt adjustment, emergency detection, simplicity. In parallel to the ongoing technical development participatory design activities have been carried out at user test sites in order to continuously involve users into the design process and to allow quick feedback with regards to early prototype parts. The project currently is working on the finalization of the first prototype ready to enter the lab trial stage in spring 2017. The experiences will be used for redesigning a prototype 2 which is planned to be tested in real life settings early 2018.
Wang, Tao; Zhang, Caixia; Cao, Xiuqin; Yang, Zhiwei
2013-12-01
To express and purify the recombinant major outer membrane protein (MOMP) of Legionella pneumophila (Lp) as diagnostic antigen, and explore its practical value in the serological diagnosis of Lp infection. The recombinant plasmid pET-momp was transformed into the E.coli BL21 competent cells. The recombinant MOMP was induced to express, and then analyzed by SDS-PAGE electrophoresis, purified by affinity chromatography. We screened and obtained 58 positive blood serum and 32 negative blood serum using the DRG (Germany, IgG/IgM/IgA) Lp kit. The blood serum samples were detected for IgG, IgM, IgA antibody levels by indirect ELISA that we had established with the purified MOMP as the coating antigen, as well as by R&D (USA, IgG/IgM/IgA) Lp kit. Then using the receiver operating characteristic (ROC) curve, we compared these two methods in the sensitivity, specificity and consistency of the test results, for evaluating the application value of the indirect ELISA of recombinant MOMP. The approximately 45 000 recombinant MOMP was successfully expressed and purified. Compared with the indirect ELISA we established with the R&D Lp kit for detecting Lp antibody IgG, IgM and IgA in blood serum, the sensitivity of the indirect ELISA of recombinant MOMP to IgG was 90.9%, the specificity was 91.7%, the Kappa value was 0.784 (P < 0.05), and the area under the ROC curve was 0.913; the sensitivity to IgM was 91.4% and the specificity was 90.6%, the Kappa value was 0.809 (P < 0.05), and the area under the ROC curve was 0.910; the sensitivity to IgA was 92.1% and the specificity was 88.9%, the Kappa value was 0.793(P < 0.05), and the area under the ROC curve was 0.905. The recombinant MOMP was successfully induced to express and purified. The indirect ELISA we established with the recombinant MOMP protein as a diagnostic antigen showed good specificity, sensitivity and consistency, which laid a foundation for the development of serological diagnosis kit of Legionnaires' disease.
Rapid and cheap prototyping of a microfluidic cell sorter.
Islam, M Z; McMullin, J N; Tsui, Y Y
2011-05-01
Development of a microfluidic device is generally based on fabrication-design-fabrication loop, as, unlike the microelectronics design, there is no rigorous simulation-based verification of the chip before fabrication. This usually results in extremely long, and hence expensive, product development cycle if micro/nano fabrication facilities are used from the beginning of the cycle. Here, we illustrate a novel approach of device prototyping that is fast, cheap, reliable, and most importantly, this technique can be adopted even if no state-of-the-art microfabrication facility is available. A water-jet machine is used to cut the desired microfluidic channels into a thin steel plate which is then used as a template to cut the channels into a thin sheet of a transparent and cheap polymer material named Surlyn® by using a Hot Knife™. The feature-inscribed Surlyn sheet is bonded in between two microscope glass slides by utilizing the techniques which has been being used in curing polymer film between dual layer automotive glasses for years. Optical fibers are inserted from the sides of chip and are bonded by UV epoxy. To study the applicability of this prototyping approach, we made a basic microfluidic sorter and tested its functionalities. Sample containing microparticles is injected into the chip. Light from a 532-nm diode laser is coupled into the optical fiber that delivers light to the interrogation region in the channel. The emitted light from the particle is collected by a photodiode (PD) placed over the detection window. The device sorts the particles into the sorted or waste outlets depending on the level of the PD signal. We used fluorescent latex beads to test the detection and sorting functionalities of the device. We found that the system could detect all the beads that passed through its geometric observation region and could sort almost all the beads it detected. Copyright © 2011 International Society for Advancement of Cytometry.
[Review of driver fatigue/drowsiness detection methods].
Wang, Lei; Wu, Xiaojuan; Yu, Mengsun
2007-02-01
Driver fatigue/drowsiness is one of the important causes of serious traffic accidents and results in so many people deaths or injuries, but also substantial directly and indirectly economic expenses. Therefore, many countries make great effort on how to detect drowsiness during driving. In this paper, we introduce the recent developments of driver fatigue/drowsiness detection technology of world wide and try to classify the existing methods into several kinds according to different features measured, and analyzed. Finally, the challenges faced to fatigue/drowsiness detection technology and the development trend are presented.
Cui, T.J.; Chew, W.C.; Aydiner, A.A.; Wright, D.L.; Smith, D.V.; Abraham, J.D.
2000-01-01
Two numerical models to simulate an enhanced very early time electromagnetic (VETEM) prototype system that is used for buried-object detection and environmental problems are presented. In the first model, the transmitting and receiving loop antennas accurately analyzed using the method of moments (MoM), and then conjugate gradient (CG) methods with the fast Fourier transform (FFT) are utilized to investigate the scattering from buried conducting plates. In the second model, two magnetic dipoles are used to replace the transmitter and receiver. Both the theory and formulation are correct and the simulation results for the primary magnetic field and the reflected magnetic field are accurate.
NASA Astrophysics Data System (ADS)
Wagle, Sanat; Habib, Anowarul; Melandsø, Frank
2017-07-01
High-frequency transducers made from a layer-by-layer deposition method are investigated as transducers for ultrasonic imaging. Prototypes of adhesive-free transducers with four active elements were made on a high-performance poly(ether imide) substrate with precision milled spherical cavities used to produce focused ultrasonic beams. The transducer prototypes were characterized using a pulse-echo experimental setup in a water tank using a glass plate as a reflector. Then, transducer was used in a three-dimensional ultrasonic scanning tank, to produce high-resolution ultrasonic images of flexible electronic circuits with the aim to detect defects in the outermost cover layer.
Field test results with the targeted search MCSA. [multi-channel spectrum analyzer for SETI
NASA Technical Reports Server (NTRS)
Tarter, J. C.
1988-01-01
In April 1985, a 74,000 channel prototype of the multichannel spectrum analyzer (MCSA) that NASA plans to use in a systematic search for extraterrestrial intelligence (SETI) was installed at DSS13, a 26 meter R&D antenna facility at the Goldstone Deep Space Network (DSN) site. Since that time the instrumentation has been used to validate the performance of signal detection algorithms using locally injected signals and the weak carriers from distant spacecraft. This paper describes results from the Goldstone Field Tests and plans to move the prototype equipment to other sites where SETI may be conducted in the future.
RED Alert – Early warning or detection of global re-emerging infectious disease (RED)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deshpande, Alina
This is the PDF of a presentation for a webinar given by Los Alamos National Laboratory (LANL) on the early warning or detection of global re-emerging infectious disease (RED). First, there is an overview of LANL biosurveillance tools. Then, information is given about RED Alert. Next, a demonstration is given of a component prototype. RED Alert is an analysis tool that can provide early warning or detection of the re-emergence of an infectious disease at the global level, but through a local lens.
Image Analysis via Fuzzy-Reasoning Approach: Prototype Applications at NASA
NASA Technical Reports Server (NTRS)
Dominguez, Jesus A.; Klinko, Steven J.
2004-01-01
A set of imaging techniques based on Fuzzy Reasoning (FR) approach was built for NASA at Kennedy Space Center (KSC) to perform complex real-time visual-related safety prototype tasks, such as detection and tracking of moving Foreign Objects Debris (FOD) during the NASA Space Shuttle liftoff and visual anomaly detection on slidewires used in the emergency egress system for Space Shuttle at the launch pad. The system has also proved its prospective in enhancing X-ray images used to screen hard-covered items leading to a better visualization. The system capability was used as well during the imaging analysis of the Space Shuttle Columbia accident. These FR-based imaging techniques include novel proprietary adaptive image segmentation, image edge extraction, and image enhancement. Probabilistic Neural Network (PNN) scheme available from NeuroShell(TM) Classifier and optimized via Genetic Algorithm (GA) was also used along with this set of novel imaging techniques to add powerful learning and image classification capabilities. Prototype applications built using these techniques have received NASA Space Awards, including a Board Action Award, and are currently being filed for patents by NASA; they are being offered for commercialization through the Research Triangle Institute (RTI), an internationally recognized corporation in scientific research and technology development. Companies from different fields, including security, medical, text digitalization, and aerospace, are currently in the process of licensing these technologies from NASA.
Motion Planning in a Society of Intelligent Mobile Agents
NASA Technical Reports Server (NTRS)
Esterline, Albert C.; Shafto, Michael (Technical Monitor)
2002-01-01
The majority of the work on this grant involved formal modeling of human-computer integration. We conceptualize computer resources as a multiagent system so that these resources and human collaborators may be modeled uniformly. In previous work we had used modal for this uniform modeling, and we had developed a process-algebraic agent abstraction. In this work, we applied this abstraction (using CSP) in uniformly modeling agents and users, which allowed us to use tools for investigating CSP models. This work revealed the power of, process-algebraic handshakes in modeling face-to-face conversation. We also investigated specifications of human-computer systems in the style of algebraic specification. This involved specifying the common knowledge required for coordination and process-algebraic patterns of communication actions intended to establish the common knowledge. We investigated the conditions for agents endowed with perception to gain common knowledge and implemented a prototype neural-network system that allows agents to detect when such conditions hold. The literature on multiagent systems conceptualizes communication actions as speech acts. We implemented a prototype system that infers the deontic effects (obligations, permissions, prohibitions) of speech acts and detects violations of these effects. A prototype distributed system was developed that allows users to collaborate in moving proxy agents; it was designed to exploit handshakes and common knowledge Finally. in work carried over from a previous NASA ARC grant, about fifteen undergraduates developed and presented projects on multiagent motion planning.
NASA Astrophysics Data System (ADS)
Dreißigacker, Anne; Köhler, Eberhard; Fabel, Oliver; van Gasselt, Stephan
2014-05-01
At the Planetary Sciences and Remote Sensing research group at Freie Universität Berlin an SCD-based X-Ray Fluorescence Spectrometer is being developed to be employed on planetary orbiters to conduct direct, passive energy-dispersive x-ray fluorescence measurements of planetary surfaces through measuring the emitted X-Ray fluorescence induced by solar x-rays and high energy particles. Because the Sun is a highly variable radiation source, the intensity of solar X-Ray radiation has to be monitored constantly to allow for comparison and signal calibration of X-Ray radiation from lunar surface materials. Measurements are obtained by indirectly monitoring incident solar x-rays emitted from a calibration sample. This has the additional advantage of minimizing the risk of detector overload and damage during extreme solar events such as high-energy solar flares and particle storms as only the sample targets receive the higher radiation load directly (while the monitor is never directly pointing towards the Sun). Quantitative data are being obtained and can be subsequently analysed through synchronous measurement of fluorescence of the Moon's surface by the XRF-S main instrument and the emitted x-ray fluorescence of calibration samples by the XRF-S-ISM (Indirect Solar Monitor). We are currently developing requirements for 3 sample tiles for onboard correction and calibration of XRF-S, each with an area of 3-9 cm2 and a maximum weight of 45 g. This includes development of design concepts, determination of techniques for sample manufacturing, manufacturing and testing of prototypes and statistical analysis of measurement characteristics and quantification of error sources for the advanced prototypes and final samples. Apart from using natural rock samples as calibration sample, we are currently investigating techniques for sample manufacturing including laser sintering of rock-glass on metals, SiO2-stabilized mineral-powders, or artificial volcanic glass. High precision measurements of the chemical composition of the final samples (EPMA, various energy-dispersive XRF) will serve as calibration standard for XRF-S. Development is funded by the German Aerospace Agency under grant 50 JR 1303.
NASA Astrophysics Data System (ADS)
Mullen, Kaitlyn Allen
North Atlantic right whales (Eubalaena glacialis ) are among the world's most endangered cetaceans. Although protected from commercial whaling since 1949, North Atlantic right whales exhibit little to no population growth. Ship strike mortality is the leading known cause of North Atlantic right whale mortality. North Atlantic right whales exhibit developed auditory systems, and vocalize in the frequency range that dominates ship acoustic signatures. With no behavioral audiogram published, current literature assumes these whales should be able to acoustically detect signals in the same frequencies they vocalize. Recorded ship acoustic signatures occur at intensities that are similar or higher to those recorded by vocalizing North Atlantic right whales. If North Atlantic right whales are capable of acoustically detecting oncoming ship, why are they susceptible to ship strike mortality? This thesis models potential acoustic impediments to North Atlantic right whale detection of oncoming ships, and concludes the presence of modeled and observed bow null effect acoustic shadow zones, located directly ahead of oncoming ships, are likely to impair the ability of North Atlantic right whales to detect and/or localize oncoming shipping traffic. This lack of detection and/or localization likely leads to a lack of ship strike avoidance, and thus contributes to the observed high rates of North Atlantic right whale ship strike mortality. I propose that North Atlantic right whale ship strike mortality reduction is possible via reducing and/or eliminating the presence of bow null effect acoustic shadow zones. This thesis develops and tests one method for bow null effect acoustic shadow zone reduction on five ships. Finally, I review current United States policy towards North Atlantic right whale ship strike mortality in an effort to determine if the bow null effect acoustic shadow zone reduction method developed is a viable method for reducing North Atlantic right whale ship strike mortality within United States waters. I recommend that future work include additional prototype modifications and testing, application for a marine mammal scientific take authorization permit to test the modified prototype on multiple mysticete species, and continued interfacing of the prototype with evolving United States North Atlantic right whale ship strike reduction policies.
Towards hybrid pixel detectors for energy-dispersive or soft X-ray photon science
Jungmann-Smith, J. H.; Bergamaschi, A.; Brückner, M.; Cartier, S.; Dinapoli, R.; Greiffenberg, D.; Huthwelker, T.; Maliakal, D.; Mayilyan, D.; Medjoubi, K.; Mezza, D.; Mozzanica, A.; Ramilli, M.; Ruder, Ch.; Schädler, L.; Schmitt, B.; Shi, X.; Tinti, G.
2016-01-01
JUNGFRAU (adJUstiNg Gain detector FoR the Aramis User station) is a two-dimensional hybrid pixel detector for photon science applications at free-electron lasers and synchrotron light sources. The JUNGFRAU 0.4 prototype presented here is specifically geared towards low-noise performance and hence soft X-ray detection. The design, geometry and readout architecture of JUNGFRAU 0.4 correspond to those of other JUNGFRAU pixel detectors, which are charge-integrating detectors with 75 µm × 75 µm pixels. Main characteristics of JUNGFRAU 0.4 are its fixed gain and r.m.s. noise of as low as 27 e− electronic noise charge (<100 eV) with no active cooling. The 48 × 48 pixels JUNGFRAU 0.4 prototype can be combined with a charge-sharing suppression mask directly placed on the sensor, which keeps photons from hitting the charge-sharing regions of the pixels. The mask consists of a 150 µm tungsten sheet, in which 28 µm-diameter holes are laser-drilled. The mask is aligned with the pixels. The noise and gain characterization, and single-photon detection as low as 1.2 keV are shown. The performance of JUNGFRAU 0.4 without the mask and also in the charge-sharing suppression configuration (with the mask, with a ‘software mask’ or a ‘cluster finding’ algorithm) is tested, compared and evaluated, in particular with respect to the removal of the charge-sharing contribution in the spectra, the detection efficiency and the photon rate capability. Energy-dispersive and imaging experiments with fluorescence X-ray irradiation from an X-ray tube and a synchrotron light source are successfully demonstrated with an r.m.s. energy resolution of 20% (no mask) and 14% (with the mask) at 1.2 keV and of 5% at 13.3 keV. The performance evaluation of the JUNGFRAU 0.4 prototype suggests that this detection system could be the starting point for a future detector development effort for either applications in the soft X-ray energy regime or for an energy-dispersive detection system. PMID:26917124
Optimization and Characterization of a Novel Self Powered Solid State Neutron Detector
NASA Astrophysics Data System (ADS)
Clinton, Justin
There is a strong interest in detecting both the diversion of special nuclear material (SNM) from legitimate, peaceful purposes and the transport of illicit SNM across domestic and international borders and ports. A simple solid-state detector employs a planar solar-cell type p-n junction and a thin conversion layer that converts incident neutrons into detectable charged particles, such as protons, alpha-particles, and heavier ions. Although simple planar devices can act as highly portable, low cost detectors, they have historically been limited to relatively low detection efficiencies; ˜10% and ˜0.2% for thermal and fast detectors, respectively. To increase intrinsic detection efficiency, the incorporation of 3D microstructures into p-i-n silicon devices was proposed. In this research, a combination of existing and new types of detector microstructures were investigated; Monte Carlo models, based on analytical calculations, were constructed and characterized using the GEANT4 simulation toolkit. The simulation output revealed that an array of etched hexagonal holes arranged in a honeycomb pattern and filled with either enriched (99% 10B) boron or parylene resulted in the highest intrinsic detection efficiencies of 48% and 0.88% for thermal and fast neutrons, respectively. The optimal parameters corresponding to each model were utilized as the basis for the fabrication of several prototype detectors. A calibrated 252Cf spontaneous fission source was utilized to generate fast neutrons, while thermal neutrons were created by placing the 252Cf in an HDPE housing designed and optimized using the MCNP simulation software. Upon construction, thermal neutron calibration was performed via activation analysis of gold foils and measurements from a 6Li loaded glass scintillator. Experimental testing of the prototype detectors resulted in maximum intrinsic efficiencies of 4.5 and 0.12% for the thermal and fast devices, respectively. The prototype thermal device was filled with natural (19% 10B) boron; scaling the response to 99% 10B enriched boron resulted in an intrinsic efficiency of 22.5%, one of the highest results in the literature. A comparison of simulated and experimental detector responses demonstrated a high degree of correlation, validating the conceptual models.
The Low Energy Neutrino Spectrometry (LENS) Experiment and LENS prototype, μLENS, initial results
NASA Astrophysics Data System (ADS)
Yokley, Zachary
2012-03-01
LENS is a low energy solar neutrino detector that will measure the solar neutrino spectrum above 115 keV, >95% of the solar neutrino flux, in real time. The fundamental neutrino reaction in LENS is charged-current based capture on 115-In detected in a liquid scintillator medium. The reaction yields the prompt emission of an electron and the delayed emission of 2 gamma rays that serve as a time & space coincidence tag. Sufficient spatial resolution is used to exploit this signature and suppress background, particularly due to 115-In beta decay. A novel design of optical segmentation (Scintillation Lattice or SL) channels the signal light along the three primary axes. The channeling is achieved via total internal reflection by suitable low index gaps in the segmentation. The spatial resolution of a nuclear event is obtained digitally, much more precisely than possible by common time of flight methods. Advanced Geant4 analysis methods have been developed to suppress adequately the severe background due to 115-In beta decay, achieving at the same time high detection efficiency. LENS physics and detection methods along with initial results characterizing light transport in the as built μLENS prototype will be presented.
Single-cell printer: automated, on demand, and label free.
Gross, Andre; Schöndube, Jonas; Niekrawitz, Sonja; Streule, Wolfgang; Riegger, Lutz; Zengerle, Roland; Koltay, Peter
2013-12-01
Within the past years, single-cell analysis has developed into a key topic in cell biology to study cellular functions that are not accessible by investigation of larger cell populations. Engineering approaches aiming to access single cells to extract information about their physiology, phenotype, and genotype at the single-cell level are going manifold ways, meanwhile allowing separation, sorting, culturing, and analysis of individual cells. Based on our earlier research toward inkjet-like printing of single cells, this article presents further characterization results obtained with a fully automated prototype instrument for printing of single living cells in a noncontact inkjet-like manner. The presented technology is based on a transparent microfluidic drop-on-demand dispenser chip coupled with a camera-assisted automatic detection system. Cells inside the chip are detected and classified with this detection system before they are expelled from the nozzle confined in microdroplets, thus enabling a "one cell per droplet" printing mode. To demonstrate the prototype instrument's suitability for biological and biomedical applications, basic experiments such as printing of single-bead and cell arrays as well as deposition and culture of single cells in microwell plates are presented. Printing efficiencies greater than 80% and viability rates about 90% were achieved.