DOE Office of Scientific and Technical Information (OSTI.GOV)
Yinfa, Ma.
Thin-layer chromatography (TLC) is a broadly applicable separation technique. It offers many advantages over high performance liquid chromatography (HPLC), such as easily adapted for two-dimensional separation, for whole-column'' detection and for handling multiple samples, etc. However, due to its draggy development of detection techniques comparing with HPLC, TLC has not received the attention it deserves. Therefore, exploring new detection techniques is very important to the development of TLC. It is the principal of this dissertation to present a new detection method for TLC -- indirect fluorometric detection method. This detection technique is universal sensitive, nondestructive, and simple. This will bemore » described in detail from Sections 1 through Section 5. Section 1 and 3 describe the indirect fluorometric detection of anions and nonelectrolytes in TLC. In Section 2, a detection method for cations based on fluorescence quenching of ethidium bromide is presented. In Section 4, a simple and interesting TLC experiment is designed, three different fluorescence detection principles are used for the determination of caffeine, saccharin and sodium benzoate in beverages. A laser-based indirect fluorometric detection technique in TLC is developed in Section 5. Section 6 is totally different from Sections 1 through 5. An ultrasonic effect on the separation of DNA fragments in agarose gel electrophoresis is investigated. 262 refs.« less
Vásquez-Garzón, Verónica R; Rouimi, Patrick; Jouanin, Isabelle; Waeg, Georg; Zarkovic, Neven; Villa-Treviño, Saul; Guéraud, Françoise
2012-05-01
Among disruptions induced by oxidative stress, modifications of proteins, particularly irreversible carbonylation, are associated with the development of several diseases, including cardiovascular diseases, neurodegenerative diseases, and cancer. Carbonylation of proteins can occur directly or indirectly through the adduction of lipid oxidation products. In this study, three classical and easy-to-perform techniques to detect direct or indirect carbonylation of proteins were compared. A model protein apomyoglobin and a complex mixture of rat liver cytosolic proteins were exposed to cumene hydroperoxide oxidation or adduction to the lipid peroxidation product 4-hydroxynonenal in order to test direct or indirect carbonylation, respectively. The technique using a specific anti-4-hydroxynonenal-histidine adduct antibody was effective to detect in vitro modification of model apomyoglobin and cytosolic proteins by 4-hydroxynonenal but not by direct carbonylation which was achieved by techniques using biotin-coupled hydrazide or dinitrophenylhydrazine derivatization of carbonyls. Sequential use of these methods enabled the detection of both direct and indirect carbonyl modification in proteins, although constitutively biotinylated proteins were detected by biotin-hydrazide. Although rather classical and efficient, methods for carbonyl detection on proteins in oxidative stress studies may be biased by some artifactual detections and complicated by proteins multimerizations. The use of more and more specific available antibodies is recommended to complete detection of lipid peroxidation product adducts on proteins.
Remote Leak Detection: Indirect Thermal Technique
NASA Technical Reports Server (NTRS)
Clements, Sandra
2002-01-01
Remote sensing technologies are being considered for efficient, low cost gas leak detection. Eleven specific techniques have been identified for further study and evaluation of several of these is underway. The Indirect Thermal Technique is one of the techniques that is being explored. For this technique, an infrared camera is used to detect the temperature change of a pipe or fitting at the site of a gas leak. This temperature change is caused by the change in temperature of the gas expanding from the leak site. During the 10-week NFFP program, the theory behind the technique was further developed, experiments were performed to determine the conditions for which the technique might be viable, and a proof-of-concept system was developed and tested in the laboratory.
The indirect fluorescent antibody technique as a method for detecting antibodies in aborted fetuses.
Miller, R B; Wilkie, B N
1979-01-01
In this investigation the indirect fluorescent antibody technique was used to titrate antibodies in bovine sera to parainfluenza 3, infectious bovine rhinotracheitis virus and bovine viral diarrhea virus. These results were compared to those determined on the same samples by hemagglutination inhibition for parainfluenza 3 virus and serum neutralization for bovine virus diarrhea and infectious bovine rhinotracheitis virus. The results of the serological methods agreed closely. The indirect fluorescent antibody technique is a rapid and sensitive method for detecting antibodies and the procedure lends itself to use in diagnostic laboratories. In addition to the above viruses the presence or absence of antibodies to bovine coronavirus and bovine adenovirus 3 were determined by the indirect fluorescent antibody technique in thoracic fluids from 100 aborted fetuses and 50 nonaborted fetuses. Results on these samples were not compared to hemagglutination inhibition or serum neutralization as the condition of fluid samples from aborted fetuses renders interpretation of such tests unreliable. Antibodies to one or more viruses were detected in 30 of the 100 aborted fetuses and in seven of the 50 nonaborted fetuses. Antibodies to more than one agent were detected in eleven of the 100 aborted and in one of the 50 nonaborted fetuses. Reasons for this occurrence and application of the test in determination of causes of abortion are discussed. PMID:226243
USDA-ARS?s Scientific Manuscript database
Streptococcus iniae is among the major pathogens of a large number of fish species cultured in fresh and marine recirculating and net pen production systems . The traditional plate culture technique to detect and identify S. iniae is time consuming and may be problematic due to phenotypic variations...
Ross, Martin R.; Borman, Earle K.
1963-01-01
Ross, Martin R. (Connecticut State Department of Health, Hartford) and Earle K. Borman. Direct and indirect fluorescent-antibody techniques for the psittacosis-lymphogranuloma venereum-trachoma group of agents. J. Bacteriol. 85:851–858. 1963.—Direct and indirect fluorescent-antibody (FA) techniques were developed for the detection of group antigen in infected tissue cultures and the titration of group antibody in human antiserum. The growth of the agent of meningopneumonitis (MP) in mouse embryo lung cell monolayers was followed by infectivity and complement-fixing (CF) antigen titrations, and cytological examination of FA stained cultures. Although infectivity and CF antigen reached a peak at 2 days and remained constant for an additional 3 days, only cells tested 2 to 3 days after infection were suitable for FA staining with labeled anti-MP serum because of excessive artifacts in the older cultures. Fluorescein isothiocyanate-labeled rooster and guinea pig anti-MP serums and human antipsittacosis serums were titrated in direct FA and hemagglutination-inhibition (HI) tests. The rooster conjugate showed brighter staining and higher antibody titers than the guinea pig or human conjugates and was more effective in detecting minimal amounts of virus antigen. FA staining reactions with 1 and 2 units of labeled rooster serum were inhibited by unlabeled rooster serum but clear-cut inhibition with human antipsittacosis serum could not be demonstrated. The indirect FA technique was successfully used for the titration of group antibody in human serum. A comparison of the indirect FA, HI, and CF tests showed the indirect FA technique to be intermediate in sensitivity between the HI and CF tests. None of the three tests showed significant cross reactions with human serums reactive for influenza A and B; parainfluenza 1, 2, and 3; respiratory syncytial virus; Q fever; or the primary atypical pneumonia agent. PMID:14044954
Turner, E S; Pruzansky, J J; Patterson, R; Zeiss, C R; Roberts, M
1980-02-01
Utilizing trimellityl-erythrocytes (TM-E), antibodies were detected in sera of seven workers with trimellitic anhydride (TMA) induced airway syndromes by direct haemagglutination, indirect haemagglutination with anti-human IgG, IgA or IgM or by haemolysis. Detectable levels of antibody were obtained with all three methods. The most sensitive technique was indirect haemagglutination using anti-IgG. When added as an inhibitor, TM-human serum albumin produced a 10- to 800-fold reduction in titres. TM-ovalbumin of similar epitope density was less inhibitory and sodium trimellitate the least inhibitory on a molar basis. All of the assays using haptenized human red cells were also capable of detecting anti-TM antibodies in Rhesus monkeys whose airways had been exposed to TMA. These assays are useful for detecting anti-TM antibodies and may also be adapted to demonstrate antibodies induced against other inhaled haptens in sera of environmentally exposed individuals or in animal models of such exposure.
Exploring a Nearby Habitable World...Orbiting an M-Dwarf Star
NASA Technical Reports Server (NTRS)
Deming, Drake
2010-01-01
Topics include: the landscape of extrasolar planets and detection techniques, direct and indirect detection methods, summary of the known exoplanets, exploiting transits to characterize super earth atmospheres, how to characterize exoplanet atmospheres, and emitted or reflected spectra of hot Jupiters.
Ultrasonic technique for detection of liquids in copper tubing process lines
NASA Astrophysics Data System (ADS)
Dudley, W. A.
1980-10-01
An ultrasonic pulse-echo method developed for semiquantitative measurement of liquid levels in copper tubing is described. This ultrasonic approach is of particular value when used as a pre-maintenance diagnostic tool in repairing process lines containing hazardous liquids. Performance tests show that water and similar liquids can be directly detected to fill levels as low as 1/16 in. For water fills below 1/16 in., direct level detection is impractical because of signal resolution limitations. However, this fill condition is indirectly measurable and is detected by the effect of observed degradation of the adjacent wall echo pattern. Fill conditions for liquids associated with high sound attenuation such as oil can be indirectly determined.
Current and Prospective Methods for Plant Disease Detection
Fang, Yi; Ramasamy, Ramaraja P.
2015-01-01
Food losses due to crop infections from pathogens such as bacteria, viruses and fungi are persistent issues in agriculture for centuries across the globe. In order to minimize the disease induced damage in crops during growth, harvest and postharvest processing, as well as to maximize productivity and ensure agricultural sustainability, advanced disease detection and prevention in crops are imperative. This paper reviews the direct and indirect disease identification methods currently used in agriculture. Laboratory-based techniques such as polymerase chain reaction (PCR), immunofluorescence (IF), fluorescence in-situ hybridization (FISH), enzyme-linked immunosorbent assay (ELISA), flow cytometry (FCM) and gas chromatography-mass spectrometry (GC-MS) are some of the direct detection methods. Indirect methods include thermography, fluorescence imaging and hyperspectral techniques. Finally, the review also provides a comprehensive overview of biosensors based on highly selective bio-recognition elements such as enzyme, antibody, DNA/RNA and bacteriophage as a new tool for the early identification of crop diseases. PMID:26287253
Relating to monitoring ion sources
Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore; Bounds, John Alan
2002-01-01
The apparatus and method provide techniques for monitoring the position on alpha contamination in or on items or locations. The technique is particularly applicable to pipes, conduits and other locations to which access is difficult. The technique uses indirect monitoring of alpha emissions by detecting ions generated by the alpha emissions. The medium containing the ions is moved in a controlled manner frog in proximity with the item or location to the detecting unit and the signals achieved over time are used to generate alpha source position information.
Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore
2001-01-01
The apparatus and method provide a technique for more simply measuring alpha and/or beta emissions arising from items or locations. The technique uses indirect monitoring of the emissions by detecting ions generated by the emissions, the ions being attracted electrostatically to electrodes for discharge of collection. The apparatus and method employ a chamber which is sealed around the item or location during monitoring with no air being drawn into or expelled from the chamber during the monitoring process. A simplified structure and operations arises as a result, but without impairing the efficiency and accuracy of the detection technique.
Brandt, J A; Kettering, J D; Lewis, J E
1984-01-01
The complement fixation test is currently the test employed most frequently to determine the presence of antibody to human cytomegalovirus. Several other techniques have been adapted for this purpose. A comparison of cytomegalovirus antibody titers was made between the complement fixation test, a commercially available enzyme-linked immunosorbent assay, an indirect immunofluorescent technique, and a modified indirect hemagglutination test. Forty-three serum samples were tested for antibodies by each of the above procedures. The enzyme-linked immunosorbent, immunofluorescent, and indirect hemagglutination assays were in close agreement on all samples tested; the titers obtained with these methods were all equal to or greater than the complement fixation titer for 38 of the 41 samples (92.6%). Two samples were anticomplementary in the complement fixation test but gave readable results in the other tests. The complement fixation test was the least sensitive of the procedures examined. The commercial enzyme-linked immunosorbent assay system was the most practical method and offered the highest degree of sensitivity in detecting antibodies to cytomegalovirus. PMID:6321544
Highly Sensitive Bacteriophage-Based Detection of Brucella abortus in Mixed Culture and Spiked Blood
Sergueev, Kirill V.; Filippov, Andrey A.; Nikolich, Mikeljon P.
2017-01-01
For decades, bacteriophages (phages) have been used for Brucella species identification in the diagnosis and epidemiology of brucellosis. Traditional Brucella phage typing is a multi-day procedure including the isolation of a pure culture, a step that can take up to three weeks. In this study, we focused on the use of brucellaphages for sensitive detection of the pathogen in clinical and other complex samples, and developed an indirect method of Brucella detection using real-time quantitative PCR monitoring of brucellaphage DNA amplification via replication on live Brucella cells. This assay allowed the detection of single bacteria (down to 1 colony-forming unit per milliliter) within 72 h without DNA extraction and purification steps. The technique was equally efficient with Brucella abortus pure culture and with mixed cultures of B. abortus and α-proteobacterial near neighbors that can be misidentified as Brucella spp., Ochrobactrum anthropi and Afipia felis. The addition of a simple short sample preparation step enabled the indirect phage-based detection of B. abortus in spiked blood, with the same high sensitivity. This indirect phage-based detection assay enables the rapid and sensitive detection of live B. abortus in mixed cultures and in blood samples, and can potentially be applied for detection in other clinical samples and other complex sample types. PMID:28604602
NASA Astrophysics Data System (ADS)
Bhunia, Amit; Singh, Mohit Kumar; Galvão Gobato, Y.; Henini, Mohamed; Datta, Shouvik
2018-01-01
We investigated excitonic absorptions in a GaAs/AlAs/GaAs single barrier heterostructure using both photocapacitance and photocurrent spectroscopies at room temperature. Photocapacitance spectra show well defined resonance peaks of indirect excitons formed around the Γ-AlAs barrier. Unlike DC-photocurrent spectra, frequency dependent photocapacitance spectra interestingly red shift, sharpen up, and then decrease with increasing tunneling at higher biases. Such dissimilarities clearly point out that different exciton dynamics govern these two spectral measurements. We also argue why such quantum confined dipoles of indirect excitons can have thermodynamically finite probabilities to survive even at room temperature. Finally, our observations demonstrate that the photocapacitance technique, which was seldom used to detect excitons in the past, is useful for selective detection and experimental tuning of relatively small numbers (˜1011/cm2) of photo-generated indirect excitons having large effective dipole moments in this type of quasi-two dimensional heterostructures.
Clinico-laboratory aspects of anti-nuclear and anti-native DNA antibody tests.
Webb, J
1978-01-01
Available techniques for detection of anti-nuclear antibodies are here briefly reviewed. The relatively insensitive LE cell test has been largely supplanted by the indirect immunofluorescent ANA test which should be reported in terms of titre and pattern. Specific measurement of nDNA antibodies is now a regular technique in SLE diagnosis and management.
Power-limited low-thrust trajectory optimization with operation point detection
NASA Astrophysics Data System (ADS)
Chi, Zhemin; Li, Haiyang; Jiang, Fanghua; Li, Junfeng
2018-06-01
The power-limited solar electric propulsion system is considered more practical in mission design. An accurate mathematical model of the propulsion system, based on experimental data of the power generation system, is used in this paper. An indirect method is used to deal with the time-optimal and fuel-optimal control problems, in which the solar electric propulsion system is described using a finite number of operation points, which are characterized by different pairs of thruster input power. In order to guarantee the integral accuracy for the discrete power-limited problem, a power operation detection technique is embedded in the fourth-order Runge-Kutta algorithm with fixed step. Moreover, the logarithmic homotopy method and normalization technique are employed to overcome the difficulties caused by using indirect methods. Three numerical simulations with actual propulsion systems are given to substantiate the feasibility and efficiency of the proposed method.
Varden, Lara; Smith, Britannia; Bou-Abdallah, Fadi
2017-01-01
Capillary zone electrophoresis (CZE) is a sensitive and rapid technique used for determining traces of inorganic and organic anions in potable, natural, and wastewaters. Here, CZE with indirect UV-diode array detection (CZE-DAD) was employed with a background electrolyte system comprising of an Agilent Technologies proprietary basic anion buffer at pH 12.0 and a forensic anion detection method. The limits of detection (LOD) for this method ranged between 3 and 5 ppm and involved hydrodynamic injection of 50 mbar for 6 s with a negative polarity separation voltage of −30 kV at 30°C, a detection wavelength of 350 nm and indirect reference of 275 nm. Fourteen different anions were checked for in the water samples that were examined and included bromide, chloride, thiosulfate, nitrate, nitrite, sulfate, azide, carbonate, fluoride, arsenate, phosphate, acetate, lactate, and silicate. The water samples were collected from Northern New York towns and the Raquette River water system, the third longest river in New York State and the largest watershed of the central and western Adirondacks. The concentrations detected for these anions ranged from <5.0 ppm to 260 ppm. PMID:29057145
2011-01-01
sensing an attractive technique for estimating LAI. Many vegetation indices, such as Normalized Difference Vegetation Index ( NDVI ), tend to saturate at...little or no improvement over NDVI . Furthermore, indirect ground-sampling techniques often used to evaluate the potential of vegetation indices also...landscapes makes remote sensing an attractive technique for estimating LAI. Many vegetation indices, such as Normalized Difference Vegetation Index ( NDVI
Indirect detection of dark matter with γ rays.
Funk, Stefan
2015-10-06
The details of what constitutes the majority of the mass that makes up dark matter in the Universe remains one of the prime puzzles of cosmology and particle physics today-80 y after the first observational indications. Today, it is widely accepted that dark matter exists and that it is very likely composed of elementary particles, which are weakly interacting and massive [weakly interacting massive particles (WIMPs)]. As important as dark matter is in our understanding of cosmology, the detection of these particles has thus far been elusive. Their primary properties such as mass and interaction cross sections are still unknown. Indirect detection searches for the products of WIMP annihilation or decay. This is generally done through observations of γ-ray photons or cosmic rays. Instruments such as the Fermi large-area telescope, high-energy stereoscopic system, major atmospheric gamma-ray imaging Cherenkov, and very energetic radiation imaging telescope array, combined with the future Cherenkov telescope array, will provide important complementarity to other search techniques. Given the expected sensitivities of all search techniques, we are at a stage where the WIMP scenario is facing stringent tests, and it can be expected that WIMPs will be either be detected or the scenario will be so severely constrained that it will have to be rethought. In this sense, we are on the threshold of discovery. In this article, I will give a general overview of the current status and future expectations for indirect searches of dark matter (WIMP) particles.
Indirect detection of dark matter with γ rays
Funk, Stefan
2015-01-01
The details of what constitutes the majority of the mass that makes up dark matter in the Universe remains one of the prime puzzles of cosmology and particle physics today—80 y after the first observational indications. Today, it is widely accepted that dark matter exists and that it is very likely composed of elementary particles, which are weakly interacting and massive [weakly interacting massive particles (WIMPs)]. As important as dark matter is in our understanding of cosmology, the detection of these particles has thus far been elusive. Their primary properties such as mass and interaction cross sections are still unknown. Indirect detection searches for the products of WIMP annihilation or decay. This is generally done through observations of γ-ray photons or cosmic rays. Instruments such as the Fermi large-area telescope, high-energy stereoscopic system, major atmospheric gamma-ray imaging Cherenkov, and very energetic radiation imaging telescope array, combined with the future Cherenkov telescope array, will provide important complementarity to other search techniques. Given the expected sensitivities of all search techniques, we are at a stage where the WIMP scenario is facing stringent tests, and it can be expected that WIMPs will be either be detected or the scenario will be so severely constrained that it will have to be rethought. In this sense, we are on the threshold of discovery. In this article, I will give a general overview of the current status and future expectations for indirect searches of dark matter (WIMP) particles. PMID:24821791
Fernández, Pilar; Gabaldón, José Antonio; Periago, Mª Jesús
2017-12-01
Alicyclobacillus acidoterrestris is a thermotolerant bacterium able to grow in fruit juices and drinks, as the spoilage by Alicyclobacillus in the final product does not product any gas, but leads to a "medicine flavor" due to the formation of guaicol. Also, its detection is a challenge for the quality control departments, because it takes several days to get the results of traditional microbiology methods. This study aimed at developing a more accurate electrical impedance technique for the detection of A. acidoterrestris in concentrated apple juice. Samples of apple juice were inoculated with A. acidoterrestris spores isolated from a peach and grape juice. For the spore germination, several heat-shock treatments were tested (80 °C/10 min, 70 °C/20 min and 60 °C/30 min). Direct and indirect electrical impedance was applied to detect and quantify the microorganism in the inoculated apple juice, using BAT broth and Bimedia 002A (pH 4). The 80 °C/10 min treatment was selected for spore activation. The valid electrical impedance technique was the indirect method in BAT broth, which measured the changes in the impedance through the formation of CO 2 . In addition, a positive correlation (r = 0.98, R 2 = 0.97) was observed between the classical microbiology (BAM agar) and the indirect impedance method. Copyright © 2017 Elsevier Ltd. All rights reserved.
Shear Stress Sensing using Elastomer Micropillar Arrays
NASA Technical Reports Server (NTRS)
Wohl, Christopher J.; Palmieri, Frank L.; Lin, Yi; Jackson, Allen M.; Cissoto, Alexxandra; Sheplak, Mark; Connell, John W.
2013-01-01
The measurement of shear stress developed as a fluid moves around a solid body is difficult to measure. Stresses at the fluid-solid interface are very small and the nature of the fluid flow is easily disturbed by introducing sensor components to the interface. To address these challenges, an array of direct and indirect techniques have been investigated with various advantages and challenges. Hot wire sensors and other indirect sensors all protrude significantly into the fluid flow. Microelectromechanical systems (MEMS) devices, although facilitating very accurate measurements, are not durable, are prone to contamination, and are difficult to implement into existing model geometries. One promising approach is the use of engineered surfaces that interact with fluid flow in a detectable manner. To this end, standard lithographic techniques have been utilized to generate elastomeric micropillar arrays of various lengths and diameters. Micropillars of controlled length and width were generated in polydimethylsiloxane (PDMS) elastomer using a soft-lithography technique. The 3D mold for micropillar replication was fabricated using laser ablative micromachining and contact lithography. Micropillar dimensions and mechanical properties were characterized and compared to shear sensing requirements. The results of this characterization as well as shear stress detection techniques will be discussed.
Bartholomew, J.L.; Smith, C.E.; Rohovec, J.S.; Fryer, J.L.
1989-01-01
The tissue response of Salmo gairdneri Richardson, against the myxosporean parasite. Ceratomyxa shasta (Noble), was investigated using histological techniques, scanning electron microscopy and immunological methods. The progress of infection in C. shasta-susceptible and resistant steelhead and rainbow trout was examined by standard histological techniques and by indirect fluorescent antibody methods using monoclonal antibodies directed against C. shasta antigens. Trophozoite stages were first observed in the posterior intestine and there was indication that resistance was due to the inability of the parasite to penetrate this tissue rather than to an inflammatory response. Examination of a severely infected intestine by scanning electron microscopy showed extensive destruction of the mucosal folds of the posterior intestine. Western blotting and indirect fluorescent antibody techniques were used to investigate the immunological component of the host response. No antibodies specific for C. shasta were detected by either method.
Türk, Ayşe Gözde; Sabuncu, Metin; Ünal, Sena; Önal, Banu; Ulusoy, Mübin
2016-01-01
The purpose of the study was to use the photonic imaging modality of optical coherence tomography (OCT) to compare the marginal adaptation of composite inlays fabricated by direct and indirect techniques. Class II cavities were prepared on 34 extracted human molar teeth. The cavities were randomly divided into two groups according to the inlay fabrication technique. The first group was directly restored on cavities with a composite (Esthet X HD, Dentsply, Germany) after isolating. The second group was indirectly restored with the same composite material. Marginal adaptations were scanned before cementation with an invisible infrared light beam of OCT (Thorlabs), allowing measurement in 200 µm intervals. Restorations were cemented with a self-adhesive cement resin (SmartCem2, Dentsply), and then marginal adaptations were again measured with OCT. Mean values were statistically compared by using independent-samples t-test and paired samples t-test (p<0.05), before and after cementation. Direct inlays presented statistically smaller marginal discrepancy values than indirect inlays, before (p=0.00001442) and after (p=0.00001466) cementation. Marginal discrepancy values were increased for all restorations after cementation (p=0.00008839, p=0.000000952 for direct and indirect inlays, respectively). The mean marginal discrepancy value of the direct group increased from 56.88±20.04 µm to 91.88±31.7 µm, whereas the indirect group increased from 107.54±35.63 µm to 170.29±54.83 µm. Different techniques are available to detect marginal adaptation of restorations, but the OCT system can give quantitative information about resin cement thickness and its interaction between tooth and restoration in a nondestructive manner. Direct inlays presented smaller marginal discrepancy than indirect inlays. The marginal discrepancy values were increased for all restorations that refer to cement thickness after cementation.
Montone, K. T.; Brigati, D. J.; Budgeon, L. R.
1989-01-01
This paper presents the first automated system for simultaneously detecting human papilloma, herpes simplex, adenovirus, or cytomegalovirus viral antigens and gene sequences in standard formalin-fixed, paraffin-embedded tissue substrates and tissue culture. These viruses can be detected by colorimetric in situ nucleic acid hybridization, using biotinylated DNA probes, or by indirect immunoperoxidase techniques, using polyclonal or monoclonal antibodies, in a 2.0-hour assay performed at a single automated robotic workstation. Images FIG. 1 FIG. 4 FIG. 5 FIG. 6 FIG. 7 FIG. 8 FIG. 9 FIG. 10 FIG. 11 PMID:2773514
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mao, Kanmi; Pruski, Marek
Two-dimensional through-bond {sup 1}H({sup 13}C) solid-state NMR experiments utilizing fast magic angle spinning (MAS) and homonuclear multipulse {sup 1}H decoupling are presented. Remarkable efficiency of polarization transfer can be achieved at MAS rates exceeding 40 kHz, which is instrumental in these measurements. Schemes utilizing direct and indirect detection of heteronuclei are compared in terms of resolution and sensitivity. A simple procedure for optimization of {sup 1}H homonuclear decoupling sequences under these conditions is proposed. The capabilities of these techniques were confirmed on two naturally abundant solids, tripeptide N-formyl-l-methionyl-l-leucyl-l-phenylalanine (f-MLF-OH) and brown coal.
NASA Astrophysics Data System (ADS)
Mao, Kanmi; Pruski, Marek
2009-12-01
Two-dimensional through-bond 1H{ 13C} solid-state NMR experiments utilizing fast magic angle spinning (MAS) and homonuclear multipulse 1H decoupling are presented. Remarkable efficiency of polarization transfer can be achieved at MAS rates exceeding 40 kHz, which is instrumental in these measurements. Schemes utilizing direct and indirect detection of heteronuclei are compared in terms of resolution and sensitivity. A simple procedure for optimization of 1H homonuclear decoupling sequences under these conditions is proposed. The capabilities of these techniques were confirmed on two naturally abundant solids, tripeptide N- formyl- L-methionyl- L-leucyl- L-phenylalanine (f-MLF-OH) and brown coal.
López, Lissett; Venteo, Angel; Aguirre, Enara; García, Marga; Rodríguez, Majosé; Amusátegui, Inmaculada; Tesouro, Miguel A; Vela, Carmen; Sainz, Angel; Rueda, Paloma
2007-11-01
An indirect enzyme-linked immunosorbent assay (ELISA) based on baculovirus recombinant P30 protein of Ehrlichia canis and the 1BH4 anticanine IgG monoclonal antibody was developed and evaluated by examining a panel of 98 positive and 157 negative sera using the indirect fluorescent antibody (IFA) test as the reference technique. The P30-based ELISA appeared to be sensitive and specific (77.55% and 95.54%, respectively) when qualitative results (positive/negative) were compared with those of the IFA test; the coefficient of correlation (R) between the 2 tests was 0.833. Furthermore, it was possible to establish a mathematical formula for use in comparing the results of both techniques. These results indicate that recombinant P30 antigen-based ELISA is a suitable alternative of the IFA test for simple, consistent, and rapid serodiagnosis of canine ehrlichiosis. Moreover, the use of this recombinant protein as antigen offers a great advantage for antigen preparation in comparison with other techniques in which the whole E. canis organism is used as antigen.
Li, Chuanfeng; Shen, Chanjuan; Cheng, Anchun; Wang, Mingshu; Zhang, Na; Zhou, Yi; Zhu, Dekang; Jia, Renyong; Luo, Qihui; Chen, Xiaoyue
2010-01-01
An improved indirect immunoperoxidase assay (IPA) was developed to detect antigens of Duck swollen head hemorrhagic disease virus (DSHDV) in paraformaldehyde-fixed, paraffin-embedded tissues of Pekin ducks (Anas platyrhynchos). This technique used an indirect streptavidin-alkaline phosphatase labeling system with polyclonal antiserum developed against purified DSHDV antigens. Specimens from the experimentally inoculated Pekin ducks with DSHDV and archived paraffin-embedded tissues from natural cases of Duck viral swollen head hemorrhagic disease (DVSHD) were examined by clinical and histological criteria. Positive staining was most widely observed in the cytoplasm of the following organs: immune, digestive, and urinary organs, heart, lung, and trachea, which corresponded to the intracellular distribution of reovirus. The DSHDV antigens were first detected at 4 hr postinoculation in the bursa of Fabricius of infected ducks. Therefore, this method was suitable for the early diagnosis of DVSHD. Immunoperoxidase staining was not present in tissues and organs of sham-inoculated ducks (negative control). The IPA developed in the current study is a convenient, sensitive, and specific means of detecting DSHDV and is applicable to routine diagnosis, retrospective studies, and prospective studies of DSHDV infection in ducks.
Heleg-Shabtai, Vered; Gratziany, Natzach; Liron, Zvi
2006-05-01
The application of indirect LIF (IDLIF) technique for on-chip electrophoretic separation and detection of the nerve agent O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothiolate (VX) and its major phosphonic degradation products, ethyl methylphosphonic acid (EMPA) and methylphosphonic acid (MPA) was demonstrated. Separation and detection of MPA degradation products of VX and the nerve agent isopropyl methylphosphonofluoridate (GB) are presented. The negatively charged dye eosin was found to be a good fluorescent marker for both the negatively charged phosphonic acids and the positively charged VX, and was chosen as the IDLIF visualization fluorescent dye. Separation and detection of VX, EMPA, and MPA in a simple-cross microchip were completed within less than a minute, and consumed only a 50 pL sample volume. A characteristic system peak that appeared in all IDLIF electropherograms served as an internal standard that increased the reliability of peak identification. The negative peak of both VX and the MPAs is in agreement with indirect detection theory and with previous reports in the literature. The LOD of VX and EMPA by IDLIF was 30 and 37 microM, respectively. Despite the fact that the detection sensitivity is relatively low, the rapid simultaneous on-chip analysis of both VX and its degradation products as well as the separation and detection of the MPA degradation products of both VX and GB, increases detection reliability and may present a choice when sensitivity is not critical compared with speed and simplicity of the assay.
Western blotting using chemiluminescent substrates.
Alegria-Schaffer, Alice
2014-01-01
Western blotting is a powerful and commonly used tool to identify and quantify a specific protein in a complex mixture (Towbin et al., 1979). The technique enables indirect detection of protein samples immobilized on a nitrocellulose or polyvinylidene fluoride (PVDF) membrane. Copyright © 2014 Elsevier Inc. All rights reserved.
Varden, Lara; Bou-Abdallah, Fadi
2017-01-01
Capillary zone electrophoresis (CZE) is a sensitive and rapid technique for determining traces of inorganic cations in water samples. CZE with indirect UV-diode array detection (CZE-DAD) was utilized to identify several inorganic cations in natural, potable, and wastewater samples. A pH 4.35 background electrolyte system was employed and consisted of 15 mM imidazole, 8 mM malonic acid, 2 mM 18-crown-6 ether as complexing agents, 10% v/v methanol as an organic modifier with indirect absorbance reference at 214 nm. The CZE method involved electromigration injection at 5 kV for 5 s, a separation voltage of 20 kV at 25°C, and a detection wavelength of 280 nm. Six main cations (ammonium NH4+, potassium K+, calcium Ca2+, sodium Na+, magnesium Mg2+, and lead Pb2+) were tested, and all but lead, were detected in the water samples at concentrations between 0.03 and 755 ppm with a detection limit ranging between 0.023 and 0.084 ppm. The successful evaluation of the proposed methodology allowed us to reliably detect and separate six metal ions in different water samples without any pretreatment. All water samples were collected from Northern New York towns and the Raquette River water system, the third longest river in New York State and the largest watershed of the central and western Adirondacks. PMID:29057144
TÜRK, Ayşe Gözde; SABUNCU, Metin; ÜNAL, Sena; ÖNAL, Banu; ULUSOY, Mübin
2016-01-01
ABSTRACT Objective The purpose of the study was to use the photonic imaging modality of optical coherence tomography (OCT) to compare the marginal adaptation of composite inlays fabricated by direct and indirect techniques. Material and Methods Class II cavities were prepared on 34 extracted human molar teeth. The cavities were randomly divided into two groups according to the inlay fabrication technique. The first group was directly restored on cavities with a composite (Esthet X HD, Dentsply, Germany) after isolating. The second group was indirectly restored with the same composite material. Marginal adaptations were scanned before cementation with an invisible infrared light beam of OCT (Thorlabs), allowing measurement in 200 µm intervals. Restorations were cemented with a self-adhesive cement resin (SmartCem2, Dentsply), and then marginal adaptations were again measured with OCT. Mean values were statistically compared by using independent-samples t-test and paired samples t-test (p<0.05), before and after cementation. Results Direct inlays presented statistically smaller marginal discrepancy values than indirect inlays, before (p=0.00001442) and after (p=0.00001466) cementation. Marginal discrepancy values were increased for all restorations after cementation (p=0.00008839, p=0.000000952 for direct and indirect inlays, respectively). The mean marginal discrepancy value of the direct group increased from 56.88±20.04 µm to 91.88±31.7 µm, whereas the indirect group increased from 107.54±35.63 µm to 170.29±54.83 µm. Different techniques are available to detect marginal adaptation of restorations, but the OCT system can give quantitative information about resin cement thickness and its interaction between tooth and restoration in a nondestructive manner. Conclusions Direct inlays presented smaller marginal discrepancy than indirect inlays. The marginal discrepancy values were increased for all restorations that refer to cement thickness after cementation. PMID:27556210
Fault Detection and Isolation for Hydraulic Control
NASA Technical Reports Server (NTRS)
1987-01-01
Pressure sensors and isolation valves act to shut down defective servochannel. Redundant hydraulic system indirectly senses failure in any of its electrical control channels and mechanically isolates hydraulic channel controlled by faulty electrical channel so flat it cannot participate in operating system. With failure-detection and isolation technique, system can sustains two failed channels and still functions at full performance levels. Scheme useful on aircraft or other systems with hydraulic servovalves where failure cannot be tolerated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mao, Kanmi
The development of fast magic angle spinning (MAS) opened up an opportunity for the indirect detection of insensitive low-γ nuclei (e.g., 13C and 15N) via the sensitive high-{gamma} nuclei (e.g., 1H and 19F) in solid-state NMR, with advanced sensitivity and resolution. In this thesis, new methodology utilizing fast MAS is presented, including through-bond indirectly detected heteronuclear correlation (HETCOR) spectroscopy, which is assisted by multiple RF pulse sequences for 1H- 1H homonuclear decoupling. Also presented is a simple new strategy for optimization of 1H- 1H homonuclear decoupling. As applications, various classes of materials, such as catalytic nanoscale materials, biomolecules, and organic complexes, are studied by combining indirect detection and other one-dimensional (1D) and two-dimensional (2D) NMR techniques. Indirectly detected through-bond HETCOR spectroscopy utilizing refocused INEPT (INEPTR) mixing was developed under fast MAS (Chapter 2). The time performance of this approach in 1H detected 2D 1H{l_brace} 13C{r_brace} spectra was significantly improved, by a factor of almost 10, compared to the traditional 13C detected experiments, as demonstrated by measuring naturally abundant organic-inorganic mesoporous hybrid materials. The through-bond scheme was demonstrated as a new analytical tool, which provides complementary structural information in solid-state systems in addition to through-space correlation. To further benefit the sensitivity of the INEPT transfer in rigid solids, the combined rotation and multiple-pulse spectroscopy (CRAMPS) was implemented for homonuclear 1H decoupling under fast MAS (Chapter 3). Several decoupling schemes (PMLG5 m more » $$\\bar{x}$$, PMLG5 mm $$\\bar{x}$$x and SAM3) were analyzed to maximize the performance of through-bond transfer based on decoupling efficiency as well as scaling factors. Indirect detection with assistance of PMLG m $$\\bar{x}$$ during INEPTR transfer proved to offer the highest sensitivity gains of 3-10. In addition, the CRAMPS sequence was applied under fast MAS to increase the 1H resolution during t 1 evolution in the traditional, 13C detected HETCOR scheme. Two naturally abundant solids, tripeptide N-formyl-L-methionyl-L-leucyl-L-phenylalanine (f-MLF-OH) and brown coal, with well ordered and highly disordered structures, respectively, are studied to confirm the capabilities of these techniques. Concomitantly, a simple optimization of 1H homonuclear dipolar decoupling at MAS rates exceeding 10 kHz was developed (Chapter 4). The fine-tuned decoupling efficiency can be obtained by minimizing the signal loss due to transverse relaxation in a simple spin-echo experiment, using directly the sample of interest. The excellent agreement between observed decoupling pattern and earlier theoretical predictions confirmed the utility of this strategy. The properties of naturally abundant surface-bound fluorocarbon groups in mesoporous silica nanoparticles (MSNs) were investigated by the above-mentioned multidimensional solid-state NMR experiments and theoretical modeling (Chapter 5). Two conformations of (pentafluorophenyl)propyl groups (abbreviated as PFP) were determined as PFP-prone and PFP-upright, whose aromatic rings are located above the siloxane bridges and in roughly upright position, respectively. Several 1D and 2D NMR techniques were implemented in the characterizations, including indirectly detected 1H{l_brace} 13C{r_brace} and 19F{l_brace} 13C{r_brace} 2D HETCOR, Carr-Purcell-Meiboom-Gill (CPMG) assisted 29Si direct polarization and 29Si 19F 2D experiments, 2D double-quantum (DQ) 19F MAS NMR spectra and spin-echo measurements. Furthermore, conformational details of two types of PFP were confirmed by theoretical calculation, operated by Dr. Takeshi Kobayashi. Finally, the arrangement of two surfactants, cetyltrimetylammoium bromide (CTAB) and cetylpyridinium bromide (CPB), mixed inside the MSN pores, was studied by solid-state NMR (Chapter 6). By analyzing the 1H- 1H DQMAS and NOESY correlation spectra, the CTAB and CPB molecules were shown to co-exist inside the pores without forming significant monocomponent domains. A 'folded-over' conformation of CPB headgroups was proposed according to the results from 1H- 29Si 2D HETCOR.« less
Remote photoacoustic detection of liquid contamination of a surface.
Perrett, Brian; Harris, Michael; Pearson, Guy N; Willetts, David V; Pitter, Mark C
2003-08-20
A method for the remote detection and identification of liquid chemicals at ranges of tens of meters is presented. The technique uses pulsed indirect photoacoustic spectroscopy in the 10-microm wavelength region. Enhanced sensitivity is brought about by three main system developments: (1) increased laser-pulse energy (150 microJ/pulse), leading to increased strength of the generated photoacoustic signal; (2) increased microphone sensitivity and improved directionality by the use of a 60-cm-diameter parabolic dish; and (3) signal processing that allows improved discrimination of the signal from noise levels through prior knowledge of the pulse shape and pulse-repetition frequency. The practical aspects of applying the technique in a field environment are briefly examined, and possible applications of this technique are discussed.
Influenza surveillance: alternative laboratory techniques for a developing country*
Canil, K. A.; Pratt, D.; Sungu, M. S.; Phillips, P. A.
1985-01-01
In developing countries it is often impractical to use conventional methods to isolate and identify influenza viruses. The use of trypsin-treated LLC-MK2 cells for the isolation of myxoviruses, in conjunction with the indirect fluorescent antibody technique for identification of isolates and for direct detection of viral antigens in specimens, was an effective combination of techniques which enabled our laboratory in Papua New Guinea to participate in an influenza surveillance programme. The application of these techniques in routine respiratory virus surveillance and in the investigation of an outbreak of influenza-like illness is described. PMID:3872737
Detecting dark matter in the Milky Way with cosmic and gamma radiation
NASA Astrophysics Data System (ADS)
Carlson, Eric C.
Over the last decade, experiments in high-energy astroparticle physics have reached unprecedented precision and sensitivity which span the electromagnetic and cosmic-ray spectra. These advances have opened a new window onto the universe for which little was previously known. Such dramatic increases in sensitivity lead naturally to claims of excess emission, which call for either revised astrophysical models or the existence of exotic new sources such as particle dark matter. Here we stand firmly with Occam, sharpening his razor by (i) developing new techniques for discriminating astrophysical signatures from those of dark matter, and (ii) by developing detailed foreground models which can explain excess signals and shed light on the underlying astrophysical processes at hand. We concentrate most directly on observations of Galactic gamma and cosmic rays, factoring the discussion into three related parts which each contain significant advancements from our cumulative works. In Part I we introduce concepts which are fundamental to the Indirect Detection of particle dark matter, including motivations, targets, experiments, production of Standard Model particles, and a variety of statistical techniques. In Part II we introduce basic and advanced modelling techniques for propagation of cosmic-rays through the Galaxy and describe astrophysical gamma-ray production, as well as presenting state-of-the-art propagation models of the Milky Way.Finally, in Part III, we employ these models and techniques in order to study several indirect detection signals, including the Fermi GeV excess at the Galactic center, the Fermi 135 GeV line, the 3.5 keV line, and the WMAP-Planck haze.
Iftikhar, Irim; Irfan, Seema; Farooqi, Joveria; Azizullah, Zahida; Hasan, Rumina
2017-01-01
With the rise in multidrug-resistant tuberculosis, there is a search for newer techniques that will rapidly detect drug-resistant Mycobacterium tuberculosis. Although molecular techniques can detect resistance, culture is still considered gold standard, especially in resource-limited settings where quick, cheap, and easy techniques are needed. The aim of the study was to evaluate microcolony method thin layer agar (TLA) for quick detection of resistance against the first- and second-line antituberculous drugs in clinical isolates. This was a cross-sectional study performed at Aga Khan University Hospital. A total of 87 Z-N stain smear-positive pulmonary samples were received and indirect drug susceptibility test (ID-DST) was performed using Lowenstein-Jensen and mycobacteria growth indicator tube. Direct DST was performed using TLA on 7H10 agar. TLA was observed twice weekly under microscope for 4 weeks. Sensitivity, specificity, and accuracy were calculated for TLA using indirect susceptibility method as the gold standard. Level of agreement was calculated using Kappa score. TLA showed sensitivity of 89% and 95.2% for isoniazid and rifampicin, while for ethionamide, ofloxacin, and injectable aminoglycosides, it was 96.6%, 92.1%, and 100%, respectively. Specificity for the first-line drugs was >95% while second-line drugs ranged from 70% to 100%. Mean time to positivity was 10.2 days by TLA as compared to 43.1 days by ID-DST. TLA is a quick and reliable method in identifying resistance, especially in resource-limited settings. However, additional liquid culture can be set up as backup, especially in patients on therapy to avoid false negative results.
Ben M'hadheb, Manel; Harrabi, Myriam; Souii, Amira; Jrad-Battikh, Nadia; Gharbi, Jawhar
2015-03-01
Influenza viruses are negative stranded segmented RNA viruses belonging to Orthomyxoviridae family. They are classified into three types A, B, and C. Type A influenza viruses are classified into subtypes according to the antigenic characters of the surface glycoproteins: hemagglutinin (H) and neuraminidase (N). The aim of the present study is to develop a fast and reliable multiplex RT-PCR technique for detecting simultaneously the subtypes A/H1N1 and A/H3N2 of influenza virus. Our study included 398 patients (mean age 30.33 ± 19.92 years) with flu or flu-like syndromes, consulting physicians affiliated with collaborating teams. A multiplex RT-PCR detecting A/H1N1 and A/H3N2 influenza viruses and an examination by indirect immunofluorescence (IFI) were performed. In the optimized conditions, we diagnosed by IFI a viral infection in 90 patients (22.6 %): 85 cases of influenza type A, four cases of influenza type B, and only one case of coinfection with types A and B. An evaluation of the technique was performed on 19 clinical specimens positive in IFI, and we detected eight cases of A/H3N2, five cases of A/H1N1, one case of influenza virus type A which is not an H1N1 nor H3N2, and five negative cases. Multiplex RT-PCR is a sensitive technique allowing an effective and fast diagnosis of respiratory infections caused by influenza viruses in which the optimization often collides with problems of sensibility.
Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore
2001-01-01
The apparatus and method provide a technique for improving detection of alpha and/or beta emitting sources on items or in locations using indirect means. The emission forms generate ions in a medium surrounding the item or location and the medium is then moved to a detecting location where the ions are discharged to give a measure of the emission levels. To increase the level of ions generated and render the system particularly applicable for narrow pipes and other forms of conduits, the medium pressure is increased above atmospheric pressure. STATEMENT REGARDING FEDERALLY SPONSORED RESEARCH OR DEVELOPMENT
Krieger, E A; Samodova, O V; Gulakova, N N; Aruiev, A B; Krylova, L A; Titova, L V
2015-11-01
Every year about 800,000 cases of intestinal infections end in lethal outcome due to dehydration. The different types of dehydration acquire differential approach to correction. Everywhere there is no application of routine detection of osmolarity of blood plasma under exicosis in children in view of absence of possibility of instrumental measurement. The search of techniques is needed to make it possible to indirectly detect types of dehydration in children hospitalized because of acute intestinal infection with purpose to apply rationale therapy of water-electrolyte disorders. The sampling of 32 patients with intestinal infections accompanied with signs of exicosis degree I-III was examined. The detection of osmolarity of blood was implemented by instrumental technique using gas analyzer ABL 800 Flex (Radiometer; Denmark) and five estimate techniques according to results of biochemical analysis of blood. The differences in precision of measurement of osmolarity of blood plasma by instrumental and estimate techniques were compared using Bland-Altman graphic technique. It is established that formula: 2x[Na+kp] + [glucosekp] (mmol/l) is the most recise. Its application provided results comparable with values detected by instrumental mode.
Indirect radioimmunoassay for thymus leukemia (TL) antigens. [Mice, /sup 125/I tracer technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Esmon, N.L.; Little, J.R.
1976-09-01
An indirect radioimmunoassay for thymus leukemia TL antigens has been developed and its specificity documented. The assay makes use of anti-TL antibodies produced in congenic mice (A-Tla/sup b/) and radioiodinated purified rabbit anti-mouse IgG. Using this assay, differences can be detected in the amounts of antigen expressed on thymocytes of the three known phenotypes (TL.1,2,3; TL.2; TL/sup -/) of inbred mouse strains. Significant differences are also detected in comparison of the thymocytes from homozygous TL.1,2,3 mice (A-Tla/sup a/) and heterozygotes from Tla/sup a/ and Tla/sup b/ parents. Optimum conditions for the assay have been established. Its ability to detect antigensmore » on glutaraldehyde-fixed cells and the binding of noncytolytic antibodies on both viable and fixed cells are documented. The assay has also been used to quantitate the changes in TL antigen expression on cells incubated in anti-TL antisera under conditions of antigenic modulation.« less
NASA Astrophysics Data System (ADS)
Carnevale, Diego; Ji, Xiao; Bodenhausen, Geoffrey
2017-11-01
Nitrogen-14 NMR spectra at fast magic-angle spinning rates can be acquired indirectly by means of two-dimensional techniques based on double cross polarization transfer 1H → 14N →1H. Experimental evidence is given for polycrystalline samples of glycine, l-histidine, and the dipeptide Ala-Gly. Either one-bond or long-range correlations can be favored by choosing the length of the cross polarization contact pulses. Longer contact pulses allow the detection of unprotonated nitrogen sites. In contrast to earlier methods that exploited second-order quadrupolar/dipolar cross-terms, cross polarization operates in the manner of the method of Hartmann and Hahn, even for 14N quadrupolar couplings up to 4 MHz. Simulations explain why amorphous samples tend to give rise to featureless spectra because the 14N quadrupolar interactions may vary dramatically with the lattice environment. The experiments are straightforward to set up and are shown to be effective for different nitrogen environments and robust with respect to the rf-field strengths and to the 14N carrier frequency during cross polarization. The efficiency of indirect detection of 14N nuclei by double cross polarization is shown to be similar to that of isotopically enriched 13C nuclei.
Habets, J M; Tank, B; Vuzevski, V D; van Reede, E C; Stolz, E; van Joost, T
1987-01-01
This report deals with the reaction pattern(s) of two monoclonal antibodies (MoAbs) with normal skin and basal cell carcinomas (BCC). Using indirect immunoperoxidase (IIP) and indirect immunofluorescence (IIF) techniques, MoAb 12 G7 was observed to react with a determinant related to the cell membrane of the epidermal basal cells. In the IIP technique MoAb 12 G7 showed a positive reaction with 32 out of 34 BCC (94%), while in IIF all the 14 BCC that were studied were positive. In most cases only the cells at the periphery of the tumour nests were stained. MoAb 253 B7 reacted with cytoplasmic determinant(s) of the epidermal basal cells both in the IIF as well as in the IIP techniques. Using the IIP technique only 5 out of 34 BCC (15%) showed a positive reaction with this MoAb. Four of the 5 positively staining tumours showed aggressive histological features. Using IIF technique only 2 out of 14 BCC were positive. The results presented in this communication are discussed with regard to the possible expression of selective differentiation and tumor-associated determinant(s) in BCC.
Ayele, Dawit G; Zewotir, Temesgen; Mwambi, Henry
2016-03-01
In sub-Saharan African countries, the chance of a child dying before the age of five years is high. The problem is similar in Ethiopia, but it shows a decrease over years. The 2000; 2005 and 2011 Ethiopian Demographic and Health Survey results were used for this work. The purpose of the study is to detect the pattern of under-five child mortality overtime. Indirect child mortality estimation technique is adapted to examine the under-five child mortality trend in Ethiopia. From the result, it was possible to see the trend of under-five child mortality in Ethiopia. The under-five child mortality shows a decline in Ethiopia. From the study, it can be seen that there is a positive correlation between mother and child survival which is almost certain in any population. Therefore, this study shows the trend of under-five mortality in Ethiopia and decline over time.
Malarial retinopathy in northern Nigerian children.
Mohammed, I; Ibrahim, U Y; Mukhtar, M; Farouq, Z; Obiagwu, P N; Yashua, A H
2010-01-01
This is a prospective study involving two centres. Children younger than 16 years old who had severe malaria underwent funduscopy. In one centre, direct ophthalmoscopy was performed by both an ophthalmologist and a non-ophthalmologist physician. At the other, two ophthalmologists performed a funduscopy on each patient using different methods (one using direct and the other indirect ophthalmoscopy). The objective was to determine the frequency of retinopathy and evaluate the effectiveness of direct ophthalmoscopy in detecting retinopathy in constantly dilated eyes. Of 62 children seen at both centres, 37% were found to have malarial retinopathy. Macula whitening was the most common finding. There was substantial agreement between the ophthalmologists using either the direct or indirect ophthalmoscopy techniques (Kappa value 0.604). However, at the centre using only direct ophthalmoscopy, there was poor agreement between the ophthalmologist and the non-ophthalmologist (kappa value -0.244). Direct ophthalmoscopy seemed to be effective in detecting malarial retinopathy, but only when performed by experienced personnel.
NASA Astrophysics Data System (ADS)
Kuraszkiewicz, Bożena
2011-01-01
The purpose of this review is to present selected tests available with the potential to detect the development of respiratory muscle fatigue in normal subjects and patients. All reviewed techniques represent a part of a variety of measures and indices, which have been employed to assess this complex process at the present time.
NASA Astrophysics Data System (ADS)
Song, Wei; Mao, Zhu; Liu, Xiaojuan; Lu, Yong; Li, Zhishi; Zhao, Bing; Lu, Lehui
2012-03-01
The detection of metabolites is very important for the estimation of the health of human beings. Latent fingerprint contains many constituents and specific contaminants, which give much information of the individual, such as health status, drug abuse etc. For a long time, many efforts have been focused on visualizing latent fingerprints, but little attention has been paid to the detection of such substances at the same time. In this article, we have devised a versatile approach for the ultra-sensitive detection and identification of specific biomolecules deposited within fingerprints via a large-area SERS imaging technique. The antibody bound to the Raman probe modified silver nanoparticles enables the binding to specific proteins within the fingerprints to afford high-definition SERS images of the fingerprint pattern. The SERS spectra and images of Raman probes indirectly provide chemical information regarding the given proteins. By taking advantage of the high sensitivity and the capability of SERS technique to obtain abundant vibrational signatures of biomolecules, we have successfully detected minute quantities of protein present within a latent fingerprint. This technique provides a versatile and effective model to detect biomarkers within fingerprints for medical diagnostics, criminal investigation and other fields.
On the comprehensibility and perceived privacy protection of indirect questioning techniques.
Hoffmann, Adrian; Waubert de Puiseau, Berenike; Schmidt, Alexander F; Musch, Jochen
2017-08-01
On surveys that assess sensitive personal attributes, indirect questioning aims at increasing respondents' willingness to answer truthfully by protecting confidentiality. However, the assumption that subjects understand questioning procedures fully and trust them to protect their privacy is rarely tested. In a scenario-based design, we compared four indirect questioning procedures in terms of their comprehensibility and perceived privacy protection. All indirect questioning techniques were found to be less comprehensible by respondents than a conventional direct question used for comparison. Less-educated respondents experienced more difficulties when confronted with any indirect questioning technique. Regardless of education, the crosswise model was found to be the most comprehensible among the four indirect methods. Indirect questioning in general was perceived to increase privacy protection in comparison to a direct question. Unexpectedly, comprehension and perceived privacy protection did not correlate. We recommend assessing these factors separately in future evaluations of indirect questioning.
Lagrange, Anne-Marie
2014-04-28
Most of the exoplanets known today have been discovered by indirect techniques, based on the study of the host star radial velocity or photometric temporal variations. These detections allowed the study of the planet populations in the first 5-8 AU from the central stars and have provided precious information on the way planets form and evolve at such separations. Direct imaging on 8-10 m class telescopes allows the detection of giant planets at larger separations (currently typically more than 5-10 AU) complementing the indirect techniques. So far, only a few planets have been imaged around young stars, but each of them provides an opportunity for unique dedicated studies of their orbital, physical and atmospheric properties and sometimes also on the interaction with the 'second-generation', debris discs. These few detections already challenge formation theories. In this paper, I present the results of direct imaging surveys obtained so far, and what they already tell us about giant planet (GP) formation and evolution. Individual and emblematic cases are detailed; they illustrate what future instruments will routinely deliver for a much larger number of stars. I also point out the limitations of this approach, as well as the needs for further work in terms of planet formation modelling. I finally present the progress expected in direct imaging in the near future, thanks in particular to forthcoming planet imagers on 8-10 m class telescopes.
Seismology of Giant Planets: General Overview and Results from the Kepler K2 Observations of Neptune
NASA Astrophysics Data System (ADS)
Gaulme, Patrick
2017-10-01
For this invited contribution, I was asked to give an overview about the application of helio and aster-oseismic techniques to study the interior of giant planets, and to specifically present the recent observations of Neptune by Kepler K2. Seismology applied to giant planets could drastically change our understanding of their deep interiors, as it has happened with the Earth, the Sun, and many main-sequence and evolved stars. The study of giant planets' composition is important for understanding both the mechanisms enabling their formation and the origins of planetary systems, in particular our own. Unfortunately, its determination is complicated by the fact that their interior is thought not to be homogeneous, so that spectroscopic determinations of atmospheric abundances are probably not representative of the planet as a whole. Instead, the determination of their composition and structure must rely on indirect measurements and interior models. Giant planets are mostly fluid and convective, which makes their seismology much closer to that of solar-like stars than that of terrestrial planets. Hence, helioseismology techniques naturally transfer to giant planets. In addition, two alternative methods can be used: photometry of the solar light reflected by planetary atmospheres, and ring seismology in the specific case of Saturn. The current decade has been promising thanks to the detection of Jupiter's acoustic oscillations with the ground-based imaging-spectrometer SYMPA and indirect detection of Saturn's f-modes in its rings by the NASA Cassini orbiter. This has motivated new projects of ground-based and space-borne instruments that are under development. The K2 observations represented the first opportunity to search for planetary oscillations with visible photometry. Despite the excellent quality of K2 data, the noise level of the power spectrum of the light curve was not low enough to detect Neptune's oscillations. The main results from the K2 observations are the clear detection of the well-known differential rotation of Neptune, measured for the first time through the rotational modulation of its photometry, and the detection of the Sun's oscillations, for the first time in an indirect way in intensity measurements.
Indirect techniques in nuclear astrophysics: a review.
Tribble, R E; Bertulani, C A; Cognata, M La; Mukhamedzhanov, A M; Spitaleri, C
2014-10-01
In this review, we discuss the present status of three indirect techniques that are used to determine reaction rates for stellar burning processes, asymptotic normalization coefficients, the Trojan Horse method and Coulomb dissociation. A comprehensive review of the theory behind each of these techniques is presented. This is followed by an overview of the experiments that have been carried out using these indirect approaches.
Farnia, Parissa; Masjedi, Mohammad Reza; Mohammadi, Foroozan; Tabarsei, Payam; Farnia, Poopak; Mohammadzadeh, Ali Reza; Baghei, Parvaneh; Varahram, Mohammad; Hoffner, Sven; Velayati, Ali Akbar
2008-01-01
The malachite green microtube (MGMT) susceptibility assay was performed directly on sputum specimens (n = 80) and indirectly on Mycobacterium tuberculosis clinical isolates (n = 60). The technique is based on the malachite green dye, which changes color in response to M. tuberculosis growth. The MGMT assay is simple and rapid and does not require expensive instruments. PMID:18094133
Fluorescence-Assisted Gamma Spectrometry for Surface Contamination Analysis
NASA Astrophysics Data System (ADS)
Ihantola, Sakari; Sand, Johan; Perajarvi, Kari; Toivonen, Juha; Toivonen, Harri
2013-02-01
A fluorescence-based alpha-gamma coincidence spectrometry approach has been developed for the analysis of alpha-emitting radionuclides. The thermalization of alpha particles in air produces UV light, which in turn can be detected over long distances. The simultaneous detection of UV and gamma photons allows detailed gamma analyses of a single spot of interest even in highly active surroundings. Alpha particles can also be detected indirectly from samples inside sealed plastic bags, which minimizes the risk of cross-contamination. The position-sensitive alpha-UV-gamma coincidence technique reveals the presence of alpha emitters and identifies the nuclides ten times faster than conventional gamma spectrometry.
Indirect detection of infinite-speed MAS solid-state NMR spectra
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perras, Frédéric A.; Venkatesh, Amrit; Hanrahan, Michael P.
Heavy spin-1/2 nuclides are known to possess very large chemical shift anisotropies that can challenge even the most advanced magic-angle-spinning (MAS) techniques. Wide manifolds of overlapping spinning sidebands and insufficient excitation bandwidths often obfuscate meaningful spectral information and force the use of static, low-resolution solid-state (SS)NMR methods for the characterization of materials. In order to address these issues, we have merged fast-magic-angle-turning (MAT) and dipolar heteronuclear multiple-quantum coherence (D-HMQC) experiments to obtain D-HMQC-MAT pulse sequences which enable the rapid acquisition of 2D SSNMR spectra that correlate isotropic 1H chemical shifts to the indirectly detected isotropic “infinite-MAS” spectra of heavy spin-1/2more » nuclides. Furthermore, for these nuclides, the combination of fast MAS and 1H detection provides a high sensitivity, which rivals the DNP-enhanced ultra-wideline SSNMR. The new pulse sequences were used to determine the Pt coordination environments in a complex mixture of decomposition products of transplatin and in a metal-organic framework with Pt ions coordinated to the linker ligands.« less
Indirect detection of infinite-speed MAS solid-state NMR spectra
Perras, Frédéric A.; Venkatesh, Amrit; Hanrahan, Michael P.; ...
2017-01-18
Heavy spin-1/2 nuclides are known to possess very large chemical shift anisotropies that can challenge even the most advanced magic-angle-spinning (MAS) techniques. Wide manifolds of overlapping spinning sidebands and insufficient excitation bandwidths often obfuscate meaningful spectral information and force the use of static, low-resolution solid-state (SS)NMR methods for the characterization of materials. In order to address these issues, we have merged fast-magic-angle-turning (MAT) and dipolar heteronuclear multiple-quantum coherence (D-HMQC) experiments to obtain D-HMQC-MAT pulse sequences which enable the rapid acquisition of 2D SSNMR spectra that correlate isotropic 1H chemical shifts to the indirectly detected isotropic “infinite-MAS” spectra of heavy spin-1/2more » nuclides. Furthermore, for these nuclides, the combination of fast MAS and 1H detection provides a high sensitivity, which rivals the DNP-enhanced ultra-wideline SSNMR. The new pulse sequences were used to determine the Pt coordination environments in a complex mixture of decomposition products of transplatin and in a metal-organic framework with Pt ions coordinated to the linker ligands.« less
Indirect detection of infinite-speed MAS solid-state NMR spectra
NASA Astrophysics Data System (ADS)
Perras, Frédéric A.; Venkatesh, Amrit; Hanrahan, Michael P.; Goh, Tian Wei; Huang, Wenyu; Rossini, Aaron J.; Pruski, Marek
2017-03-01
Heavy spin-1/2 nuclides are known to possess very large chemical shift anisotropies that can challenge even the most advanced magic-angle-spinning (MAS) techniques. Wide manifolds of overlapping spinning sidebands and insufficient excitation bandwidths often obfuscate meaningful spectral information and force the use of static, low-resolution solid-state (SS)NMR methods for the characterization of materials. To address these issues, we have merged fast-magic-angle-turning (MAT) and dipolar heteronuclear multiple-quantum coherence (D-HMQC) experiments to obtain D-HMQC-MAT pulse sequences which enable the rapid acquisition of 2D SSNMR spectra that correlate isotropic 1H chemical shifts to the indirectly detected isotropic "infinite-MAS" spectra of heavy spin-1/2 nuclides. For these nuclides, the combination of fast MAS and 1H detection provides a high sensitivity, which rivals the DNP-enhanced ultra-wideline SSNMR. The new pulse sequences were used to determine the Pt coordination environments in a complex mixture of decomposition products of transplatin and in a metal-organic framework with Pt ions coordinated to the linker ligands.
X-Ray Fluorescence Solvent Detection at the Substrate-Adhesive Interface
NASA Technical Reports Server (NTRS)
Wurth, Laura; Evans, Kurt; Weber, Bart; Headrick, Sarah
2005-01-01
With environmental regulations limiting the use of volatile organic compounds, low-vapor pressure solvents have replaced traditional degreasing solvents for bond substrate preparation. When used to clean and prepare porous bond substrates such as phenolic composites, low vapor pressure solvents can penetrate deep into substrate pore networks and remain there for extended periods. Trapped solvents can interact with applied adhesives either prior to or during cure, potentially compromising bond properties. Currently, methods for characterizing solvent time-depth profiles in bond substrates are limited to bulk gravimetric or sectioning techniques. While sectioning techniques such as microtome allow construction of solvent depth profiles, their depth resolution and reliability are limited by substrate type. Sectioning techniques are particularly limited near the adhesive-substrate interface where depth resolution is further limited by adhesive-substrate hardness and, in the case of a partially cured adhesive, mechanical properties differences. Additionally, sectioning techniques cannot provide information about lateral solvent diffusion. Cross-section component mapping is an alternative method for measuring solvent migration in porous substrates that eliminates the issues associated with sectioning techniques. With cross-section mapping, the solvent-wiped substrate is sectioned perpendicular rather than parallel to the wiped surface, and the sectioned surface is analyzed for the solvent or solvent components of interest using a two-dimensional mapping or imaging technique. Solvent mapping can be performed using either direct or indirect methods. With a direct method, one or more solvent components are mapped using red or Raman spectroscopy together with a moveable sample stage and/or focal plane array detector. With an indirect method, an elemental "tag" not present in the substrate is added to the solvent before the substrate is wiped. Following cross sectioning, the tag element can then be mapped by its characteristic x-ray emission using either x-ray fluorescence, or electron-beam energy-and wavelength-dispersive x-ray spectrometry. The direct mapping techniques avoid issues of different diffusion or migration rates of solvents and elemental tags, while the indirect techniques avoid spectral resolution issues in cases where solvents and substrates have adjacent or overlapping peaks. In this study, cross-section component indirect mapping is being evaluated as a method for measuring migration of d-limonene based solvents in glass-cloth phenolic composite (GCP) prior to and during subsequent bonding and epoxy adhesive cure.
Haugen, Tommy; Ommundsen, Yngvar; Seiler, Stephen
2013-02-01
The aim of this study was to investigate if physical fitness (strength/power, endurance, flexibility and coordination) mediates the cross-sectional relationship between physical activity and physical self-perception (athletic competence and physical appearance) in a sample of 15-year old adolescents. We wanted to investigate the relative strength of each indirect effect. The present data are taken from two waves of a larger data collection for the project "Youth in Balance", and was collected in the autumn of 2005 (N = 1207) and 2008 (N = 632). A total of 1839 students (889 girls and 950 boys) from 12 schools in Kristiansand took part. A bias-corrected bootstrapping technique was used to examine indirect effects. Results revealed that cardiovascular endurance, lower-body strength/power, and upper-body strength stood out as unique mediators in the relationship between physical activity and athletic competence in both genders. Furthermore, there was an indirect effect of physical activity on physical appearance through physical strength/power and flexibility in males. No indirect effects of physical activity on physical appearance through actual physical fitness indices were detected in females.
Cartilage magnetic resonance imaging techniques at 3 T: current status and future directions.
Thakkar, Rashmi S; Subhawong, Ty; Carrino, John A; Chhabra, Avneesh
2011-04-01
Magnetic resonance imaging (MRI) remains the imaging modality of choice for morphological and compositional evaluation of the articular cartilage. Accurate detection and characterization of cartilage lesions are necessary to guide the medical and surgical therapy and are also critical for longitudinal studies of the cartilage. Recent work using 3.0-T MRI systems shows promise in improving detection and characterization of the cartilage lesions, particularly with increasing use of high-resolution and high-contrast 3-dimensional sequences, which allow detailed morphological assessment of cartilage in arbitrary imaging planes. In addition, implementation of biochemical sequences in clinically feasible scan times has a potential in the early detection of cartilage lesions before they become morphologically apparent. This article discusses relative advantages and disadvantages of various commonly used as well as experimental MRI techniques to directly assess the morphology and indirectly evaluate the biochemical composition of the articular cartilage.
A Comparison of implant impression precision: Different materials and techniques
Tabesh, Mahtab; Alikhasi, Marzieh
2018-01-01
Background Precision of implant impressions is a prerequisite for long-term success of implant supported prostheses. Impression materials and impression techniques are two important factors that impression precision relies on. Material and Methods A model of edentulous maxilla containing four implants inserted by All-on-4 guide was constructed. Seventy two impressions using polyether (PE), polyvinyl siloxane (PVS), and vinyl siloxanether (VSE) materials with direct and indirect techniques were made (n=12). Coordinates of implants in casts were measured using coordinate measuring machine (CMM). Data were analyzed with ANOVA; t-test and Tukey test were used for post hoc. Results With two-way ANOVA, mean values of linear displacements of implants were significantly different among materials and techniques. One-way ANOVA and Tukey showed significant difference between PE and VSE (P=0.019), PE and PVS (P=0.002) in direct technique, and between PVS and PE (P<0.001), PVS and VSE (P<0.001) in indirect technique. One-way ANOVA and t-test showed significant difference between the two techniques in PVS groups (P<0.001) and in PE groups (P=0.02). Two-way ANOVA showed mean values of rotational displacement of implants were significantly different among materials. One-way ANOVA and Tukey test showed significant difference between PVS and PE (P=0.001) and between PVS and VSE (P=0.012) in indirect groups. Conclusions On the basis of the results, when deciding on the material to make an impression of implants, PE is recommended for direct technique while PE and VSE are recommended for indirect technique. Recommended technique for VSE is either direct or indirect; and for PE and PVS is direct. Key words:Polyvinyl siloxane, polyether, vinyl siloxanether, direct technique, indirect technique, All-on-4, coordinate measuring machine. PMID:29670733
Accuracy of cast posts fabricated by the direct and the indirect techniques.
Rayyan, Mohammad R; Aldossari, Roa'a A; Alsadun, Sarah F; Hijazy, Fatimah R
2016-09-01
Patterns for custom cast posts and cores can be fabricated either by the direct or the indirect technique. Which technique is more accurate is unknown. The purpose of this in vitro study was to investigate the effect of pattern fabrication technique on the accuracy of post fit. Ten intact extracted premolar teeth with a single canal and similar dimensions received root canal treatment. The teeth were sectioned 2 mm above the cementoenamel junction. A total of 20 cast post and core patterns, 2 for each tooth, were fabricated, 10 with the direct technique and 10 with the indirect technique. Patterns were cast to produce 20 cast post and cores. Each tooth was scanned using a microcomputed tomography (μCT) system with a resolution of 14.5 μm, once with the post of the direct technique and once with the post of the indirect technique. Ct analyzer software was used to calculate the overall space between the post and canal walls and the space areas in 3 different standardized sections. The Student paired t test was used to determine any significant difference in the scores of the groups. The overall space between the canal walls and posts made with the direct technique ranged between 7.86 and 17.39 mm(3), with a mean value of 12.25 mm(3), whereas with the indirect technique, the space ranged between 6.68 and 18.02 mm(3), with a mean of 11.92 mm(3). No significant differences were found between the results of either technique (P>.05). Within the limitations of this study, neither the indirect nor direct pattern fabrication technique influenced the accuracy of post fitting. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Song, Wei; Mao, Zhu; Liu, Xiaojuan; Lu, Yong; Li, Zhishi; Zhao, Bing; Lu, Lehui
2012-04-07
The detection of metabolites is very important for the estimation of the health of human beings. Latent fingerprint contains many constituents and specific contaminants, which give much information of the individual, such as health status, drug abuse etc. For a long time, many efforts have been focused on visualizing latent fingerprints, but little attention has been paid to the detection of such substances at the same time. In this article, we have devised a versatile approach for the ultra-sensitive detection and identification of specific biomolecules deposited within fingerprints via a large-area SERS imaging technique. The antibody bound to the Raman probe modified silver nanoparticles enables the binding to specific proteins within the fingerprints to afford high-definition SERS images of the fingerprint pattern. The SERS spectra and images of Raman probes indirectly provide chemical information regarding the given proteins. By taking advantage of the high sensitivity and the capability of SERS technique to obtain abundant vibrational signatures of biomolecules, we have successfully detected minute quantities of protein present within a latent fingerprint. This technique provides a versatile and effective model to detect biomarkers within fingerprints for medical diagnostics, criminal investigation and other fields. This journal is © The Royal Society of Chemistry 2012
de Sequeira, Danielly C M; Peixoto, Mariana L P; De Luca, Paula M; Oliveira-Ferreira, Joseli; Antas, Paulo R Z; Borba, Cintia M
2013-10-31
Purpureocillium lilacinum is an emerging pathogenic fungus that can cause different clinical manifestations ranging from cutaneous and sub-cutaneous infections to severe oculomycosis. In this study, using both conventional indirect immunofluorescence and non-conventional flow cytometry approaches, IgG antibodies were readily detected in both C57BL/6 immunocompetent and immunosuppressed mice after i.v. infection with P. lilacinum. The humoral immune response was specific, since virtually no antibodies were detected in the serum of control mice. Flow cytometry assays also showed both quantitative and qualitative differences in total IgG and its isotypes in sera of immunocompetent and immunosupressed infected mice. Although a good starting point, it is clear that the effectiveness of serological assays for P. lilacinum hyalohyphomycosis identification in clinical studies still requires further standardization. Upon further validation in humans, these techniques have the potential to be suitable to detect P. lilacinum infection in patients, thereby avoiding current laborious and time-consuming culture techniques. © 2013.
Human Fascioliasis: A Re-emerging Disease in Upper Egypt
Mekky, Mohamed A.; Tolba, Mohammed; Abdel-Malek, Mohamed O.; Abbas, Wael A.; Zidan, Mohamed
2015-01-01
In recent years, the number of humans infected with Fasciola has risen rapidly. Diagnosis is based mainly on detection of eggs in stool analysis. The rate of infection in Egypt is unknown. In this retrospective study, we describe 23 cases of hepatic fascioliasis, and only 2 of these cases showed eggs in stools. The symptoms of infection, such as pyrexia of unknown origin, epigastric pain, and abdominal distension, were suggestive. Imaging techniques, including abdominal ultrasonography and computed tomography, were very helpful in detecting hepatic changes. An indirect hemagglutination assay proved to be of value for diagnosis. Treatment using a 2-day triclabendazole regimen cured the infection and signs of hepatic involvement disappeared. Combining both imaging techniques and laboratory tests is essential for diagnosis of fascioliasis in the early stage. PMID:25870421
[Diagnosis of insulin resistance by indirect methods in obese school children].
Angulo, Nerkis; de Szarvas, Sobeida Barbella; Mathison, Yaira; Hadad, Erika; González, Dora; Hernández, Ana; Guevara, Harold
2013-06-01
Obesity leads to a deterioration of glucose tolerance and the action of insulin. The purpose of this study was to determine insulin resistance (IR) by indirect methods, and its correlation with clinical, anthropometric and biochemical variables in obese normoglycemic school children. This was a descriptive-correlational study of 72 school prepubescent children, who attended the ambulatory "El Concejo" of the University of Carabobo (UC) and at the Gastroenterology and Pediatric Nutrition service of the city hospital "Enrique Tejera" (CHET), in Valencia, Venezuela, between January-April 2011. exogenous obesity. We assessed personal and family history, presence of Acanthosis Nigricans and nutritional and biochemical status. We found a higher percentage of IR, through the use of the QUICKI method (66.7%), followed by the HOMA (55.6%) and basal insulin (45.9%). The mean (chi) indexes of body mass and waist circumference were significantly greater (p < 0.05) in patients with IR, by HOMA and QUICKI techniques. The QUICKI method detected significant differences (p < 0.05) in the values of glycemia, basal insulin and postprandial insulin, among patients with diminished and normal insulin sensitivities. While HOMA, detected these differences (p < 0.05) in the values of glycemia and basal insulin. A statistically significant relationship was observed (p < 0.05), between the presence of Acanthosis Nigricans and IR, by the HOMA, QUICKI and basal insulin methods. In conclusion, the evaluated techniques, QUICKI, HOMA and basal insulin indexes, were most effective for detecting the IR.
Voevodin, A F; Lapin, B A; Agrba, V Z; Timanovskaya, V V
1978-01-01
A new technique (indirect double immunodiffusion) for detection of EBV-associated soluble antigen and corresponding antibodies has been developed. This technique includes three steps: 1) simple double immunodiffusion with extracts of Raji cells (or other EBV-genome positive cells) and human sera containing antibodies against EBV-associated soluble antigen; 2) extensive washing and treatment with anti-human globulin; 3) extensive washing and treatment with tannic acid. Using this test it was shown that the soluble antigen indistinguishable from EBV-associated soluble antigen was present in KMPG-1 cells producing HVP.
Fine, Amanda E.; O'Brien, Daniel J.; Winterstein, Scott R.; Kaneene, John B.
2011-01-01
Deer movements on cattle farms, wildlife feeding, and livestock management practices in Michigan are thought to create opportunities for indirect transmission of Mycobacterium bovis via environmental substrates. To confirm the presence of viable M. bovis in the environment, substrates were collected from 13 farms with culture-confirmed M. bovis in cattle and 5 sites with high prevalence of M. bovis in free-ranging deer. None of the samples processed for mycobacterial culture were positive for M. bovis. Agent, host, and landscape-level factors decrease the probability of detecting M. bovis in the environment using conventional mycobacterial culture. Molecular techniques that increase the probability of M. bovis detection in environmental substrates should be applied to known sites of M. bovis transmission in Michigan. In the interim, epidemiological investigations informed by experimental studies will be most effective in characterizing M. bovis persistence in the environment and its role in the indirect interspecies transmission of M. bovis. PMID:23738108
Molla Kazemiha, Vahid; Bonakdar, Shahin; Amanzadeh, Amir; Azari, Shahram; Memarnejadian, Arash; Shahbazi, Shirin; Shokrgozar, Mohammad Ali; Mahdian, Reza
2016-08-01
Mycoplasmas are the most important contaminants of cell cultures throughout the world. They are considered as a major problem in biological studies and biopharmaceutical economic issues. In this study, our aim was to find the best standard technique as a rapid method with high sensitivity, specificity and accuracy for the detection of mycoplasma contamination in the cell lines of the National Cell Bank of Iran. Thirty cell lines suspected to mycoplasma contamination were evaluated by five different techniques including microbial culture, indirect DNA DAPI staining, enzymatic mycoalert(®) assay, conventional PCR and real-time PCR. Five mycoplasma-contaminated cell lines were assigned as positive controls and five mycoplasma-free cell lines as negative controls. The enzymatic method was performed using the mycoalert(®) mycoplasma detection kit. Real-time PCR technique was conducted by PromoKine diagnostic kits. In the conventional PCR method, mycoplasma genus-specific primers were designed to analyze the sequences based on a fixed and common region on 16S ribosomal RNA with PCR product size of 425 bp. Mycoplasma contamination was observed in 60, 56.66, 53.33, 46.66 and 33.33 % of 30 different cell cultures by real-time PCR, PCR, enzymatic mycoalert(®), indirect DNA DAPI staining and microbial culture methods, respectively. The analysis of the results of the different methods showed that the real-time PCR assay was superior the other methods with the sensitivity, specificity, accuracy, predictive value of positive and negative results of 100 %. These values were 94.44, 100, 96.77, 100 and 92.85 % for the conventional PCR method, respectively. Therefore, this study showed that real-time PCR and PCR assays based on the common sequences in the 16S ribosomal RNA are reliable methods with high sensitivity, specificity and accuracy for detection of mycoplasma contamination in cell cultures and other biological products.
Lye, Jessica C.; Hwang, Joab E. C.; Paterson, David; de Jonge, Martin D.; Howard, Daryl L.; Burke, Richard
2011-01-01
Tissue-specific manipulation of known copper transport genes in Drosophila tissues results in phenotypes that are presumably due to an alteration in copper levels in the targeted cells. However direct confirmation of this has to date been technically challenging. Measures of cellular copper content such as expression levels of copper-responsive genes or cuproenzyme activity levels, while useful, are indirect. First-generation copper-sensitive fluorophores show promise but currently lack the sensitivity required to detect subtle changes in copper levels. Moreover such techniques do not provide information regarding other relevant biometals such as zinc or iron. Traditional techniques for measuring elemental composition such as inductively coupled plasma mass spectroscopy are not sensitive enough for use with the small tissue amounts available in Drosophila research. Here we present synchrotron x-ray fluorescence microscopy analysis of two different Drosophila tissues, the larval wing imaginal disc, and sectioned adult fly heads and show that this technique can be used to detect changes in tissue copper levels caused by targeted manipulation of known copper homeostasis genes. PMID:22053217
Yeung, Edward S.; Kuhr, Werner G.
1996-02-20
A means and method for capillary zone electrphoresis with laser-induced indirect fluorescence detection. A detector is positioned on the capillary tube of a capillary zone electrophoresis system. The detector includes a laser which generates a laser beam which is imposed upon a small portion of the capillary tube. Fluorescence of the elutant electromigrating through the capillary tube is indirectly detected and recorded.
Yeung, Edwards; Kuhr, Werner G.
1991-04-09
A means and method for capillary zone electrphoresis with laser-induced indirect fluorescence detection. A detector is positioned on the capillary tube of a capillary zone electrophoresis system. The detector includes a laser which generates a laser beam which is imposed upon a small portion of the capillary tube. Fluorescence of the elutant electromigrating through the capillary tube is indirectly detected and recorded.
Martínez-Torrecuadrada, Jorge L.; Lázaro, Beatriz; Rodriguez, José F.; Casal, J. Ignacio
2000-01-01
The routine technique for detecting antibodies specific to infectious bursal disease virus (IBDV) is a serological evaluation by enzyme-linked immunosorbent assay (ELISA) with preparations of whole virions as the antigens. To avoid using complete virus in the standard technique, we have developed two new antigens through the expression of the VPX and VP3 genes in insect cells. VPX and especially VP3 were expressed at high levels in insect cells and simple to purify. The immunogenicity of both proteins was similar to that of the native virus. VPX was able to elicit neutralizing antibodies but VP3 was not. Purified VPX and VP3 were tested in an indirect ELISA with more than 300 chicken sera. There was an excellent correlation between the results of the ELISA using VPX and those of the two commercial kits. VP3 did not perform as well as VPX, and the linear correlation was significantly lower. A comparison with the standard reference technique, seroneutralization, showed that the indirect ELISA was more sensitive. Therefore, VPX-based ELISA is a good alternative to conventional ELISAs that use whole virions. PMID:10882666
Martínez-Torrecuadrada, J L; Lázaro, B; Rodriguez, J F; Casal, J I
2000-07-01
The routine technique for detecting antibodies specific to infectious bursal disease virus (IBDV) is a serological evaluation by enzyme-linked immunosorbent assay (ELISA) with preparations of whole virions as the antigens. To avoid using complete virus in the standard technique, we have developed two new antigens through the expression of the VPX and VP3 genes in insect cells. VPX and especially VP3 were expressed at high levels in insect cells and simple to purify. The immunogenicity of both proteins was similar to that of the native virus. VPX was able to elicit neutralizing antibodies but VP3 was not. Purified VPX and VP3 were tested in an indirect ELISA with more than 300 chicken sera. There was an excellent correlation between the results of the ELISA using VPX and those of the two commercial kits. VP3 did not perform as well as VPX, and the linear correlation was significantly lower. A comparison with the standard reference technique, seroneutralization, showed that the indirect ELISA was more sensitive. Therefore, VPX-based ELISA is a good alternative to conventional ELISAs that use whole virions.
Nonaqueous capillary electrophoresis with indirect electrochemical detection.
Matysik, Frank-Michael; Marggraf, Daniela; Gläser, Petra; Broekaert, José A C
2002-11-01
Nonaqueous capillary electrophoresis (NACE) which makes use of organic solvents in place of conventional aqueous electrophoresis buffers is gaining increasing importance among modern separation techniques. Recently, it has been shown that amperometric detection in conjunction with acetonitrile-based NACE offers an extended accessible potential range and an enhanced long-term stability of the amperometric responses generated at solid electrodes. The present contribution takes advantage of the latter aspect to develop reliable systems for NACE with indirect electrochemical detection (IED). In this context, several compounds such as (ferrocenylmethyl)trimethylammonium perchlorate, tris(1,10-phenanthroline)cobalt(III) perchlorate and bis(1,4,7-triazacyclononane)nickel(II) perchlorate were studied regarding their suitability to act as electroactive buffer additives for IED in NACE. The performance characteristics for the respective buffer systems were evaluated. Tetraalkylammonium perchlorates served as model compounds for the optimization of the NACE-IED system. Target analytes choline and acetylcholine could easily be separated and determined by means of NACE-IED. In the case of a buffer system containing 10(-4) M tris(1,10-phenanthroline)cobalt(III) perchlorate the limits of detection were 2.5 x 10(-7) M and 4.6 x 10(-7) M for choline and acetylcholine, respectively. With the elaborated analytical procedure choline could be determined in pharmaceutical preparations.
Liu, Na; Han, Zheng; Lu, Lei; Wang, Lin; Ni, Geng; Zhao, Zhihui; Wu, Aibo; Zheng, Xiaodong
2013-02-01
Monoclonal antibodies generally obtained through the classic mouse hybridoma system were requisite for the establishment of various immunoassays. In this study, a new rabbit monoclonal antibody (RabMAb) against sulfonamides (SAs) was first produced via hybridoma technique in rabbit. The related enzyme-linked immunosorbent assay (ELISA) was then developed and applied to real sample analysis. A sensitive competitive indirect ELISA method based on a novel RabMAb for rapid detection of sulfonamides was first established. The obtained half-maximum inhibition concentration (IC(50)) values for four SAs were all below 10 ng mL(-1) , with 0.68 ng mL(-1) sulfathiazole (STZ), 1.11 ng mL(-1) sulfadiazine (SD), 1.15 ng mL(-1) sulfapyridine (SP) and 5.27 ng mL(-1) sulfamethoxazole (SMX). Desirable recoveries when detecting different spiked swine urine and milk samples were achieved ranging from 92.6% to 104.3% and from 61.1% to 81.6%, respectively. The proposed immunoassay with the newly developed RabMAb is capable of detection of four SAs (STZ, SD, SP and SMX) with proven satisfactory performance and is applicable for routine large-scale analysis in practical uses. © 2012 Society of Chemical Industry.
Indirect detection of radiation sources through direct detection of radiolysis products
Farmer, Joseph C [Tracy, CA; Fischer, Larry E [Los Gatos, CA; Felter, Thomas E [Livermore, CA
2010-04-20
A system for indirectly detecting a radiation source by directly detecting radiolytic products. The radiation source emits radiation and the radiation produces the radiolytic products. A fluid is positioned to receive the radiation from the radiation source. When the fluid is irradiated, radiolytic products are produced. By directly detecting the radiolytic products, the radiation source is detected.
Human fascioliasis: a re-emerging disease in upper Egypt.
Mekky, Mohamed A; Tolba, Mohammed; Abdel-Malek, Mohamed O; Abbas, Wael A; Zidan, Mohamed
2015-07-01
In recent years, the number of humans infected with Fasciola has risen rapidly. Diagnosis is based mainly on detection of eggs in stool analysis. The rate of infection in Egypt is unknown. In this retrospective study, we describe 23 cases of hepatic fascioliasis, and only 2 of these cases showed eggs in stools. The symptoms of infection, such as pyrexia of unknown origin, epigastric pain, and abdominal distension, were suggestive. Imaging techniques, including abdominal ultrasonography and computed tomography, were very helpful in detecting hepatic changes. An indirect hemagglutination assay proved to be of value for diagnosis. Treatment using a 2-day triclabendazole regimen cured the infection and signs of hepatic involvement disappeared. Combining both imaging techniques and laboratory tests is essential for diagnosis of fascioliasis in the early stage. © The American Society of Tropical Medicine and Hygiene.
Geologic Carbon Sequestration Leakage Detection: A Physics-Guided Machine Learning Approach
NASA Astrophysics Data System (ADS)
Lin, Y.; Harp, D. R.; Chen, B.; Pawar, R.
2017-12-01
One of the risks of large-scale geologic carbon sequestration is the potential migration of fluids out of the storage formations. Accurate and fast detection of this fluids migration is not only important but also challenging, due to the large subsurface uncertainty and complex governing physics. Traditional leakage detection and monitoring techniques rely on geophysical observations including pressure. However, the resulting accuracy of these methods is limited because of indirect information they provide requiring expert interpretation, therefore yielding in-accurate estimates of leakage rates and locations. In this work, we develop a novel machine-learning technique based on support vector regression to effectively and efficiently predict the leakage locations and leakage rates based on limited number of pressure observations. Compared to the conventional data-driven approaches, which can be usually seem as a "black box" procedure, we develop a physics-guided machine learning method to incorporate the governing physics into the learning procedure. To validate the performance of our proposed leakage detection method, we employ our method to both 2D and 3D synthetic subsurface models. Our novel CO2 leakage detection method has shown high detection accuracy in the example problems.
Constant-Envelope Waveform Design for Optimal Target-Detection and Autocorrelation Performances
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sen, Satyabrata
2013-01-01
We propose an algorithm to directly synthesize in time-domain a constant-envelope transmit waveform that achieves the optimal performance in detecting an extended target in the presence of signal-dependent interference. This approach is in contrast to the traditional indirect methods that synthesize the transmit signal following the computation of the optimal energy spectral density. Additionally, we aim to maintain a good autocorrelation property of the designed signal. Therefore, our waveform design technique solves a bi-objective optimization problem in order to simultaneously improve the detection and autocorrelation performances, which are in general conflicting in nature. We demonstrate this compromising characteristics of themore » detection and autocorrelation performances with numerical examples. Furthermore, in the absence of the autocorrelation criterion, our designed signal is shown to achieve a near-optimum detection performance.« less
The semantic differential in landscape research
H. E. Echelberger
1979-01-01
On-site reactions of groups of viewers to six timber harvesting procedures were measured by direct and indirect measuring techniques. Using the direct technique, groups recorded their overall impressions of harvested tracts on five-point scales ranging from very favorable to very unfavorable. For the indirect technique, semantic differential procedures were used....
The Direct-Indirect Technique for Composite Restorations Revisited.
Ritter, André V; Fahl, Newton; Vargas, Marcos; Maia, Rodrigo R
2017-06-01
In the direct-indirect composite technique, composite is applied to a nonretentive tooth preparation (eg, a noncarious cervical lesion or a veneer/inlay/onlay preparation) without any bonding agent, sculpted to a primary anatomic form, and light-cured. The partially polymerized restoration is then removed from the preparation and finished and tempered extraorally chairside. The finished inlay is bonded to the preparation using a resin-based luting agent. Advantages of this technique include enhanced physical and mechanical properties afforded by the extraoral chairside tempering process because of increased monomer conversion, and greater operator control over the final marginal adaptation, surface finishing and polishing, and anatomy of the restoration, given that these elements are defined outside of the patient's mouth. The direct-indirect approach also affords enhanced gingival health and patient comfort. This article presents a clinical case in which the direct-indirect composite technique was used to restore three noncarious cervical lesions on the same quadrant on an adult patient. Clinical steps and tips for success are offered. The authors also present scanning electron microscope and atomic force microscope images showing the excellent marginal fit obtained with the direct-indirect composite technique.
Dark Matter Indirect Detection with Gamma Rays
Patrick Harding, J.
2017-07-27
Searches for weakly interacting massive particle (WIMP) dark matter with gamma-ray instruments are a way to get a unique observational handle on the particle nature of dark matter. I will discuss the details of how to perform these searches, both for annihilating and decaying WIMPs. I will discuss the calculation of the gamma-ray flux from possible sources of dark matter annihilation or decay and show examples of limits which have been calculated using these techniques.
Detection prospects of the cosmic neutrino background
NASA Astrophysics Data System (ADS)
Li, Yu-Feng
2015-04-01
The existence of the cosmic neutrino background (CνB) is a fundamental prediction of the standard Big Bang cosmology. Although current cosmological probes provide indirect observational evidence, the direct detection of the CνB in a laboratory experiment is a great challenge to the present experimental techniques. We discuss the future prospects for the direct detection of the CνB, with the emphasis on the method of captures on beta-decaying nuclei and the PTOLEMY project. Other possibilities using the electron-capture (EC) decaying nuclei, the annihilation of extremely high-energy cosmic neutrinos (EHECνs) at the Z-resonance, and the atomic de-excitation method are also discussed in this review (talk given at the International Conference on Massive Neutrinos, Singapore, 9-13 February 2015).
Emerging technologies in autoantibody testing for rheumatic diseases.
Olsen, Nancy J; Choi, May Y; Fritzler, Marvin J
2017-07-24
Testing for the presence of antinuclear antibodies (ANAs) is a key step in the diagnosis of systemic lupus erythematosus (SLE) and other systemic autoimmune rheumatic diseases (SARD). The standard slide-based indirect immunofluorescence (IIF) test is widely used, but is limited by a relative lack of specificity for SLE and not all SARD-ANAs are detected. Alternative immunoassays that might offer enhanced diagnostic and prognostic information have evolved, and some of these have entered clinical practice. This review summarizes the current state of ANA testing and multiplex techniques for detecting other autoantibodies, the possibility of point-of-care testing, and approaches for applications in early disease stages.
Sweat testing to evaluate autonomic function
Illigens, Ben M.W.; Gibbons, Christopher H.
2011-01-01
Sudomotor dysfunction is one of the earliest detectable neurophysiologic abnormalities in distal small fiber neuropathy. Traditional neurophysiologic measurements of sudomotor function include thermoregulatory sweat testing (TST), quantitative sudomotor axon reflex testing (QSART), silicone impressions, the sympathetic skin response (SSR), and the recent addition of quantitative direct and indirect axon reflex testing (QDIRT). These testing techniques, when used in combination, can detect and localized pre- and postganglionic lesions, can provide early diagnosis of sudomotor dysfunction and can monitor disease progression or disease recovery. In this article, we review the common tests available for assessment of sudomotor function, detail the testing methodology, review the limitations and provide examples of test results. PMID:18989618
Ren, Kuan; Liu, Shenye; Du, Huabing; Hou, Lifei; Jing, Longfei; Zhao, Yang; Yang, Zhiwen; Wei, Minxi; Deng, Keli; Yao, Li; Yang, Guohong; Li, Sanwei; Lan, Ke; Liu, Jie; Zhu, Xiaoli; Ding, Yongkun; Yi, Lin
2015-10-01
The space-resolving measurement of X-ray flux from a specific area (laser spot, re-emitting wall, or capsule) inside the hohlraum is an ongoing and critical problem in indirectly driven inertial-confinement fusion experiments. In this work, we developed a new two-dimensional space-resolving flux detection technique to measure the X-ray flux from specific areas inside the hohlraum by using the time- and space-resolving flux detector (SRFD). In two typical hohlraum experiments conducted at the Shenguang-III prototype laser facility, the X-ray flux and radiation temperature from an area 0.2 mm in diameter inside the hohlraum were measured through the laser entrance hole (LEH). The different flux intensities and radiation temperatures detected using the SRFD from the inner area of the LEH were compared with the result measured using the flat-response X-ray detector from the entire LEH. This comparison was also analyzed theoretically. The inner area detected using the SRFD was found to be the re-emitting wall area alone. This important improvement in space-resolving X-ray flux measurement will enhance the current X-ray flux space characterization techniques, thereby furthering the quantitative understanding of X-ray flux space behavior in the hohlraum.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ren, Kuan; Research Center of Laser Fusion, China Academy of Engineering Physics, P.O. Box 919-986, Mianyang 621900; Liu, Shenye, E-mail: lsye1029@163.com
2015-10-15
The space-resolving measurement of X-ray flux from a specific area (laser spot, re-emitting wall, or capsule) inside the hohlraum is an ongoing and critical problem in indirectly driven inertial-confinement fusion experiments. In this work, we developed a new two-dimensional space-resolving flux detection technique to measure the X-ray flux from specific areas inside the hohlraum by using the time- and space-resolving flux detector (SRFD). In two typical hohlraum experiments conducted at the Shenguang-III prototype laser facility, the X-ray flux and radiation temperature from an area 0.2 mm in diameter inside the hohlraum were measured through the laser entrance hole (LEH). Themore » different flux intensities and radiation temperatures detected using the SRFD from the inner area of the LEH were compared with the result measured using the flat-response X-ray detector from the entire LEH. This comparison was also analyzed theoretically. The inner area detected using the SRFD was found to be the re-emitting wall area alone. This important improvement in space-resolving X-ray flux measurement will enhance the current X-ray flux space characterization techniques, thereby furthering the quantitative understanding of X-ray flux space behavior in the hohlraum.« less
Lab-on-a-bubble: direct and indirect assays with portable Raman instrumentation
NASA Astrophysics Data System (ADS)
Carron, Keith; Schmit, Virginia; Scott, Brandon; Martoglio, Richard
2012-10-01
Lab-on-a-Bubble (LoB) is a new method for SERS (Surface Enhanced Raman Scattering) assays that combines separationand concentration of the assay results. A direct LoB assay is comprised of gold nanoparticles coupled directly to the ~30 μm diameter buoyant silica bubble. The direct LoB method was evaluated with cyanide and 5,5'-dithiobis(2-nitrobenzoic acid) (DTNB). An indirect assay uses the same ~ 30 μm diameter buoyant silica bubble and a silica coated SERS reporter. Both the bubble and SERS reporter are coated with a coupling agent for the analyte. The assay measures the amount of SERS reporter coupled to the bubble through a sandwich created by the analyte. The couling agent could consist of an immunological coupling agent (antibody) or a nucleic acid coupling agent (single strand DNA). The indirect LoB method was examined with Cholera toxin (CT) and antibodies against the β subunit. An LOD of ~ 170 pptrillion was measured for cyanide and a limit of detection of 1100 ng was found for CT. Instrumentation for the assay and a novel technique of dynamic SERS (DSERS) will also be discussed. The instrument is a small hand-held Raman device called the CBEx (Chemical Biological Explosive) with a novel raster system to detect heterogeneous or light sensitive materials. DSERS is a mathematical algorithm which eliminates background interference in SERS measurements with colloidal nanoparticles.
Armenta, Roberto E; Burja, Adam; Radianingtyas, Helia; Barrow, Colin J
2006-12-27
A variety of techniques for extracting carotenoids from the marine Thraustochytrium sp. ONC-T18 was compared. Specifically, the organic solvents acetone, ethyl acetate, and petroleum ether were tested, along with direct and indirect ultrasonic assisted extraction (probe vs bath) methods. Techniques that used petroleum ether/acetone/water (15:75:10, v/v/v) with 3 h of agitation, or 5 min in an ultrasonic bath, produced the highest extraction yields of total carotenoids (29-30.5 microg g-1). Concentrations up to 11.5 microg g-1 of canthaxanthin and 17.5 microg g-1 of beta;-carotene were detected in extracts stored for 6 weeks. Astaxanthin and echinenone were also detected as minor compounds. Extracts with and without antioxidants showed similar carotenoid concentration profiles. However, total carotenoid concentrations were approximately 8% higher when antioxidants were used. Finally, an easy-to-perform and inexpensive method to detect co-enzymes in ONC-T18 was also developed using silica gel TLC plates. Five percent methanol in toluene as a mobile phase consistently eluted co-enzyme Q10 standards and could separate the co-enzyme fractions present in ONC-T18.
Kirov, Ilya; Van Laere, Katrijn; De Riek, Jan; De Keyser, Ellen; Van Roy, Nadine; Khrustaleva, Ludmila
2014-01-01
In order to anchor Rosa linkage groups to physical chromosomes, a combination of the Tyramide-FISH technology and the modern molecular marker system based on High Resolution Melting (HRM) is an efficient approach. Although, Tyramide-FISH is a very promising technique for the visualization of short DNA probes, it is very challenging for plant species with small chromosomes such as Rosa. In this study, we successfully applied the Tyramide-FISH technique for Rosa and compared different detection systems. An indirect detection system exploiting biotinylated tyramides was shown to be the most suitable technique for reliable signal detection. Three gene fragments with a size of 1100 pb–1700 bp (Phenylalanine Ammonia Lyase, Pyrroline-5-Carboxylate Synthase and Orcinol O-Methyl Transferase) have been physically mapped on chromosomes 7, 4 and 1, respectively, of Rosa wichurana. The signal frequency was between 25% and 40%. HRM markers of these 3 gene fragments were used to include the gene fragments on the existing genetic linkage map of Rosa wichurana. As a result, three linkage groups could be anchored to their physical chromosomes. The information was used to check for synteny between the Rosa chromosomes and Fragaria. PMID:24755945
Immunological detection of Fusarium species in cornmeal.
Iyer, M S; Cousin, M A
2003-03-01
An indirect enzyme-linked immunosorbent assay (ELISA) was developed to detect Fusarium species in foods. Antibodies to proteins extracted from the mycelia of Fusarium graminearum and Fusarium moniliforme (verticillioides) were produced in New Zealand white rabbits. These antibodies detected 13 Fusarium species in addition to the producer strains. Levels of Fusarium semitectum and Fusarium tricinctum strains were below the detection threshold. The specificity of the assay was tested against 70 molds and yeasts belonging to 23 genera. One strain of Monascus species and one strain of Phoma exigua were detected; however, these two molds are not common contaminants of cereal grains or foods and should not interfere with the assay. The indirect ELISA's detection limits for F. graminearum and F. moniliforme were 0.1 and 1 microg of mold mycelium per ml of a cornmeal mixture, respectively. When spores of each mold were added individually to cornmeal mixtures (at ca. 10 spores per g) and incubated at 25 degrees C, these spores were detected by the indirect ELISA when they reached levels of 10(2) to 10(3) CFU/ml after 24 to 36 h. The indirect ELISA developed here shows promise for the detection of Fusarium species in grains or foods.
Indirect photometric detection of boron cluster anions electrophoretically separated in methanol.
Vítová, Lada; Fojt, Lukáš; Vespalec, Radim
2014-04-18
3,5-Dinitrobenzoate and picrate are light absorbing anions pertinent to indirect photometric detection of boron cluster anions in buffered methanolic background electrolytes (BGEs). Tris(hydroxymethyl)aminomethane and morpholine have been used as buffering bases, which eliminated baseline steps, and minimized the baseline noise. In methanolic BGEs, mobilities of boron cluster anions depend on both ionic constituents of the BGE buffer. This dependence can be explained by ion pair interaction of detected anions with BGE cations, which are not bonded into ion pairs with the BGE anions. The former ion pair interaction decreases sensitivity of the indirect photometric detection. Copyright © 2014 Elsevier B.V. All rights reserved.
Packham, Andrea E; Conrad, Patricia A; Wilson, W David; Jeanes, Lisa V; Sverlow, Karen W; Gardner, Ian A; Daft, Barbara M; Marsh, Antoinette E; Blagburn, Byron L; Ferraro, Gregory L; Barr, Bradd C
2002-12-01
Neospora hughesi is a newly recognized protozoan pathogen in horses that causes a myeloencephalitis similar to Sarcocystis neurona. There are no validated serologic tests using the gold standard sera that are currently available to detect specific N. hughesi antibodies and, thus, no tests available to detect antemortem exposure or estimate seroprevalence in the horse. The objectives of the present study were to establish a bank of gold standard equine sera through experimental infections with N. hughesi and to assess several serologic tests for the detection of related protozoan antibodies. Seven horses were inoculated with N. hughesi tachyzoites, and 7 horses received uninfected cell culture material. The horses were monitored, and blood and cerebrospinal fluid were collected repeatedly over a 4-mo period. With the sera, 4 different serologic techniques were evaluated. including a whole-parasite lysate enzyme-linked immunosorbent assay (ELISA), a recombinant protein ELISA, a modified direct agglutination test, and an indirect fluorescent antibody test. Qualitative and quantitative evaluation of the results showed that the N. hughesi indirect fluorescent antibody test (IFAT) consistently discriminated between experimentally infected and noninfected horses, using a cutoff of 1:640. Sera from 3 naturally infected horses had titers >1:640. Cerebrospinal fluid in all but I infected horse had very low N. hughesi IFAT titers (<1:160), starting at postinoculation day 30.
Aubert, D; Puygauthier-Toubas, D; Leon, P; Pignon, B; Foudrinier, F; Marnef, F; Boulant, J; Pinon, J M
1996-01-01
The proposed serological diagnosis of systemic Candida infections is based on a microplate immunocapture technique detecting IgM, IgA and IgE anti-Candida antibodies. Activity is revealed with a suspension of human erythrocytes sensitized with somatic antigen of Candida albicans, and is quantified on an automated plate reader. The sera were obtained from patients with deep-seated (n = 56) and superficial (n = 193) candidosis. We compared this immunological method with a combination of indirect immunofluorescence and co-immunoelectrodiffusion. The immunocapture method was more sensitive (80.4% vs. 48.2% with indirect immunofluorescence and 58.9% with co-immunoelectrodiffusion), and often provided the diagnosis at an earlier stage, with clear therapeutic advantages. The IgA isotype was a particularly valuable marker of deep-seated Candida infections.
RMB identification based on polarization parameters inversion imaging
NASA Astrophysics Data System (ADS)
Liu, Guoyan; Gao, Kun; Liu, Xuefeng; Ni, Guoqiang
2016-10-01
Social order is threatened by counterfeit money. Conventional anti-counterfeit technology is much too old to identify its authenticity or not. The intrinsic difference between genuine notes and counterfeit notes is its paper tissue. In this paper a new technology of detecting RMB is introduced, the polarization parameter indirect microscopic imaging technique. A conventional reflection microscopic system is used as the basic optical system, and inserting into it with polarization-modulation mechanics. The near-field structural characteristics can be delivered by optical wave and material coupling. According to coupling and conduction physics, calculate the changes of optical wave parameters, then get the curves of the intensity of the image. By analyzing near-field polarization parameters in nanoscale, finally calculate indirect polarization parameter imaging of the fiber of the paper tissue in order to identify its authenticity.
Liu, Yong-Qiang; Yu, Hong
2017-04-01
A convenient and versatile method was developed for the separation and detection of alkaline earth metal ions by ion chromatography with indirect UV detection. The chromatographic separation of Mg 2+ , Ca 2+ , and Sr 2+ was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid as the mobile phase, in which the imidazolium ionic liquid acted as an UV-absorption reagent. The effects of imidazolium ionic liquids, detection wavelength, acids in the mobile phase, and column temperature on the retention of Mg 2+ , Ca 2+ , and Sr 2+ were investigated. The main factors influencing the separation and detection were the background UV absorption reagent and the concentration of hydrogen ion in ion chromatography with indirect UV detection. The successful separation and detection of Mg 2+ , Ca 2+ , and Sr 2+ within 14 min were achieved using the selected chromatographic conditions, and the detection limits (S/N = 3) were 0.06, 0.12, and 0.23 mg/L, respectively. A new separation and detection method of alkaline earth metal ions by ion chromatography with indirect UV detection was developed, and the application range of ionic liquids was expanded. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Can indirect tests detect a known recombination event in human mtDNA?
White, Daniel James; Gemmell, Neil John
2009-07-01
Whether human mitochondrial DNA (mtDNA) recombines sufficiently to influence its evolution, evolutionary analysis, and disease etiology, remains equivocal. Overall, evidence from indirect studies of population genetic data suggests that recombination is not occurring at detectable levels. This may be explained by no, or low, recombination or, alternatively, current indirect tests may be incapable of detecting recombination in human mtDNA. To investigate the latter, we have tested whether six well-established indirect tests of recombination could detect recombination in a human mtDNA data set, in which its occurrence had been empirically confirmed. Three showed statistical evidence for recombination (r(2) vs. distance, the Homoplasy test, Neighborhood Similarity Score), and three did not (D' vs. distance, Max Chi Squared, Pairwise Homoplasy Index). Possible reasons for detection failure are discussed. Further, evidence from earlier studies suggesting a lack of recombination in mtDNA in humans is reconsidered, taking into account the appropriateness of the tests used, based on our new findings.
Possibilities for the detection of microbial life on extrasolar planets.
Knacke, Roger F
2003-01-01
We consider possibilities for the remote detection of microbial life on extrasolar planets. The Darwin/Terrestrial Planet Finder (TPF) telescope concepts for observations of terrestrial planets focus on indirect searches for life through the detection of atmospheric gases related to life processes. Direct detection of extraterrestrial life may also be possible through well-designed searches for microbial life forms. Satellites in Earth orbit routinely monitor colonies of terrestrial algae in oceans and lakes by analysis of reflected ocean light in the visible region of the spectrum. These remote sensing techniques suggest strategies for extrasolar searches for signatures of chlorophylls and related photosynthetic compounds associated with life. However, identification of such life-related compounds on extrasolar planets would require observations through strong, interfering absorptions and scattering radiances from the remote atmospheres and landmasses. Techniques for removal of interfering radiances have been extensively developed for remote sensing from Earth orbit. Comparable techniques would have to be developed for extrasolar planet observations also, but doing so would be challenging for a remote planet. Darwin/TPF coronagraph concepts operating in the visible seem to be best suited for searches for extrasolar microbial life forms with instruments that can be projected for the 2010-2020 decades, although resolution and signal-to-noise ratio constraints severely limit detection possibilities on terrestrial-type planets. The generation of telescopes with large apertures and extremely high spatial resolutions that will follow Darwin/TPF could offer striking possibilities for the direct detection of extrasolar microbial life.
Optical micromanipulation of active cells with minimal perturbations: direct and indirect pushing.
Wang, Chenlu; Chowdhury, Sagar; Gupta, Satyandra K; Losert, Wolfgang
2013-04-01
The challenge to wide application of optical tweezers in biological micromanipulation is the photodamage caused by high-intensity laser exposure to the manipulated living systems. While direct exposure to infrared lasers is less likely to kill cells, it can affect cell behavior and signaling. Pushing cells with optically trapped objects has been introduced as a less invasive alternative, but the technique includes some exposure of the biological object to parts of the optical tweezer beam. To keep the cells farther away from the laser, we introduce an indirect pushing-based technique for noninvasive manipulation of sensitive cells. We compare how cells respond to three manipulation approaches: direct manipulation, pushing, and indirect pushing. We find that indirect manipulation techniques lessen the impact of manipulation on cell behavior. Cell survival increases, as does the ability of cells to maintain shape and wiggle. Our experiments also demonstrate that indirect pushing allows cell-cell contacts to be formed in a controllable way, while retaining the ability of cells to change shape and move.
Autoantibodies against Leydig cells in patients after spermatic cord torsion.
Zanchetta, R; Mastrogiacomo, I; Graziotti, P; Foresta, C; Betterle, C
1984-01-01
This study is aimed at searching for the presence of circulating antibodies against frozen sections of human testis, ovary and trophoblast in patients that had spermatic cord torsion. Sixty-eight sera samples were studied. Nine patients (13.2%) were positive for organ specific anti-testis autoantibodies. Six patients were positive for antibodies against Leydig cells: five were positive only with the indirect immunofluorescence technique of complement fixing (ITT/CF), the sixth patient was positive only with the indirect immunofluorescence technique (ITT). The other three patients were positive for antibodies against germ line cells: two patients were positive with both techniques, the third was positive only with indirect immunofluorescence technique. Eight of these patients were negative for antibodies against adrenal cortex while only one case was positive with indirect immunofluorescence technique both on adrenal cortex and Leydig cells. Human lyophilized testis absorbed the reactive antibodies against Leydig cells and germ line cells, while adrenal cortex and lyophilized testosterone were ineffective. This study shows the identification of a specific antibody against Leydig cells and germ line cells in patients after spermatic cord torsion. PMID:6362937
NASA Astrophysics Data System (ADS)
Knicker, Heike
2016-04-01
During the last years, increasing evidences are provided that the common view of charcoal as a polyaromatic network is too much simplified. Experiments with model compounds indicated that it represents a heterogeneous mixture of thermally altered biomacromolecules with N, O and likely also S substitutions as common features. If produced from a N-rich feedstock, the so called black nitrogen (BN) has to be considered as an integral part of the aromatic charcoal network. In order to study this network one-dimensional (1D) solid-state nuclear magnetic resonance (NMR) spectroscopy is often applied. However, this technique suffers from broad resonance lines and low resolution. Applying 2D techniques can help but until recently, this was unfeasible for natural organic matter (NOM) due to sensitivity problems and the high complexity of the material. On the other hand, during the last decade, the development of stronger magnetic field instruments and advanced pulse sequences has put them into reach for NOM research. Although 2D NMR spectroscopy has many different applications, all pulse sequences are based on the introduction of a preparation time during which the magnetization of a spin system is adjusted into a state appropriate to whatever properties are to be detected in the indirect dimension. Then, the spins are allowed to evolve with the given conditions and after their additional manipulation during a mixing period the modulated magnetization is detected. Assembling several 1D spectra with incrementing evolution time creates a data set which is two-dimensional in time (t1, t2). Fourier transformation of both dimensions leads to a 2D contour plot correlating the interactions detected in the indirect dimension t1 with the signals detected in the direct dimension t2. The so called solid-state heteronuclear correlation (HETCOR) NMR spectroscopy represents a 2D technique allows the determination which protons are interacting with which carbons. In the present work this technique was used for monitoring the chemical changes occurring during charring of biomass derived from model compounds, fire-affected and unaffected NOM. The 2D 13C HETCOR NMR spectrum of the fire- unaffected soils revealed that most of the carboxyl C occurs as ester or amide. Aside from cross peaks typically seen in spectra of NOM, the spectrum of the respective fire-affected counterpart shows additional signals assignable to PyOM.
Indirect three-dimensional printing of synthetic polymer scaffold based on thermal molding process.
Park, Jeong Hun; Jung, Jin Woo; Kang, Hyun-Wook; Cho, Dong-Woo
2014-06-01
One of the major issues in tissue engineering has been the development of three-dimensional (3D) scaffolds, which serve as a structural template for cell growth and extracellular matrix formation. In scaffold-based tissue engineering, 3D printing (3DP) technology has been successfully applied for the fabrication of complex 3D scaffolds by using both direct and indirect techniques. In principle, direct 3DP techniques rely on the straightforward utilization of the final scaffold materials during the actual scaffold fabrication process. In contrast, indirect 3DP techniques use a negative mold based on a scaffold design, to which the desired biomaterial is cast and then sacrificed to obtain the final scaffold. Such indirect 3DP techniques generally impose a solvent-based process for scaffold fabrication, resulting in a considerable increase in the fabrication time and poor mechanical properties. In addition, the internal architecture of the resulting scaffold is affected by the properties of the biomaterial solution. In this study, we propose an advanced indirect 3DP technique using projection-based micro-stereolithography and an injection molding system (IMS) in order to address these challenges. The scaffold was fabricated by a thermal molding process using IMS to overcome the limitation of the solvent-based molding process in indirect 3DP techniques. The results indicate that the thermal molding process using an IMS has achieved a substantial reduction in scaffold fabrication time and has also provided the scaffold with higher mechanical modulus and strength. In addition, cell adhesion and proliferation studies have indicated no significant difference in cell activity between the scaffolds prepared by solvent-based and thermal molding processes.
Pinne, Marija; Ponce, Elsa; Raucy, Judy L
2017-01-01
Nuclear Receptors (NRs), including PXR and CAR, are presumed to be ligand-dependent transcription factors, but ligand binding is not an absolute requirement for activation. Indeed, many compounds activate PXR and CAR by indirect mechanisms. Detecting these indirect activators of specific nuclear receptors in vitro has been difficult. As NR activation of either or both PXR and CAR can lead to drug-drug interactions and adverse drug effects, false negatives obtained with screening tools incapable of detecting indirect activators could present liabilities. The aim of this study was to establish assays that identify indirect activators of human PXR and CAR. Commercially available human PXR and CAR transactivation assays were used for analyses. We show that transactivation assays containing full-length nuclear receptors with native promoters can identify indirect activators of human CAR and PXRwhen compared to those of commercially available assays containing only the LBD of PXR and CAR. Of these two assay systems, only human PXR and CAR1 assays with full-length receptors and native promoters are capable of detecting indirect and ligand activators. With this capability, several kinase inhibitors were identified that activate PXR and CAR by indirect mechanisms. Furthermore by using both the LBD and full-length receptors, phenobarbital and midostaurin were found to be direct and indirect activators of PXR while human CAR activation by phenobarbital occurs by indirect mechanisms only. Cell based transactivation assays employing the full-length receptors and native promoters identify both direct and indirect activators of either or both human PXR and CAR. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Forsey, T; Darougar, S
1980-02-01
A rapid indirect micro-immunofluorescence test capable of detecting and differentiating type-specific antibodies to herpes simplex virus is described. The test proved highly sensitive and, in 80 patients with active herpes ocular infection, antibody was detected in 94%. No anti-herpes antibody was detected in a control group of 20 patients with adenovirus infections. Testing of animal sera prepared against herpes simplex virus types 1 and 2 and of human sera from cases of ocular and genital herpes infections showed that the test can differentiate antibodies to the infecting serotypes. Specimens of whole blood, taken by fingerprick, and eye secretions, both collected on cellulose sponges, could be tested by indirect micro-immunofluorescence. Anti-herpes IgG, IgM, and IgA can also be detected.
Minimal access surgery of pediatric inguinal hernias: a review.
Saranga Bharathi, Ramanathan; Arora, Manu; Baskaran, Vasudevan
2008-08-01
Inguinal hernia is a common problem among children, and herniotomy has been its standard of care. Laparoscopy, which gained a toehold initially in the management of pediatric inguinal hernia (PIH), has managed to steer world opinion against routine contralateral groin exploration by precise detection of contralateral patencies. Besides detection, its ability to repair simultaneously all forms of inguinal hernias (indirect, direct, combined, recurrent, and incarcerated) together with contralateral patencies has cemented its role as a viable alternative to conventional repair. Numerous minimally invasive techniques for addressing PIH have mushroomed in the past two decades. These techniques vary considerably in their approaches to the internal ring (intraperitoneal, extraperitoneal), use of ports (three, two, one), endoscopic instruments (two, one, or none), sutures (absorbable, nonabsorbable), and techniques of knotting (intracorporeal, extracorporeal). In addition to the surgeons' experience and the merits/limitations of individual techniques, it is the nature of the defect that should govern the choice of technique. The emerging techniques show a trend toward increasing use of extracorporeal knotting and diminishing use of working ports and endoscopic instruments. These favor wider adoption of minimal access surgery in addressing PIH by surgeons, irrespective of their laparoscopic skills and experience. Growing experience, wider adoption, decreasing complications, and increasing advantages favor emergence of minimal access surgery as the gold standard for the treatment of PIH in the future. This article comprehensively reviews the laparoscopic techniques of addressing PIH.
Arjona, Alvaro; Barquero, Nuria; Doménech, Ana; Tejerizo, German; Collado, Victorio M; Toural, Cristina; Martín, Daniel; Gomez-Lucia, Esperanza
2007-02-01
Laboratory diagnosis of feline leukemia virus (FeLV) and feline immunodeficiency virus (FIV) usually involves both viruses, as the clinical signs are similar and coinfection may occur. Serological methods may not represent an accurate diagnosis: maternal antibodies or cross-reactions may give false positive results to FIV, and false negative results may occur in latent FeLV status, or in certain FIV infection stages. A nested polymerase chain reaction (PCR) technique was designed to detect FeLV, FIV and feline endogenous retrovirus simultaneously. The detection of endogenous sequences was considered indicative of successful DNA extraction. The technique was used to diagnose FIV and FeLV in the blood cells of 179 cats. The kappa value with the serological data was 0.69 for FeLV and 0.87 for FIV. The joint detection of FeLV and FIV by this novel nested PCR is sensitive, specific, fast and convenient, and its applicability for clinical diagnosis is promising, as the direct evidence of the presence of the virus is more realistic than the indirect data provided by the serological detection.
Duyvejonck, Hans; Cools, Piet; Decruyenaere, Johan; Roelens, Kristien; Noens, Lucien; Vermeulen, Stefan; Claeys, Geert; Decat, Ellen; Van Mechelen, Els; Vaneechoutte, Mario
2015-01-01
Candida species are known as opportunistic pathogens, and a possible cause of invasive infections. Because of their species-specific antimycotic resistance patterns, reliable techniques for their detection, quantification and identification are needed. We validated a DNA amplification method for direct detection of Candida spp. from clinical samples, namely the ITS2-High Resolution Melting Analysis (direct method), by comparing it with a culture and MALDI-TOF Mass Spectrometry based method (indirect method) to establish the presence of Candida species in three different types of clinical samples. A total of 347 clinical samples, i.e. throat swabs, rectal swabs and vaginal swabs, were collected from the gynaecology/obstetrics, intensive care and haematology wards at the Ghent University Hospital, Belgium. For the direct method, ITS2-HRM was preceded by NucliSENS easyMAG DNA extraction, directly on the clinical samples. For the indirect method, clinical samples were cultured on Candida ID and individual colonies were identified by MALDI-TOF. For 83.9% of the samples there was complete concordance between both techniques, i.e. the same Candida species were detected in 31.1% of the samples or no Candida species were detected in 52.8% of the samples. In 16.1% of the clinical samples, discrepant results were obtained, of which only 6.01% were considered as major discrepancies. Discrepancies occurred mostly when overall numbers of Candida cells in the samples were low and/or when multiple species were present in the sample. Most of the discrepancies could be decided in the advantage of the direct method. This is due to samples in which no yeast could be cultured whereas low amounts could be detected by the direct method and to samples in which high quantities of Candida robusta according to ITS2-HRM were missed by culture on Candida ID agar. It remains to be decided whether the diagnostic advantages of the direct method compensate for its disadvantages.
Indirect Charged Particle Detection: Concepts and a Classroom Demonstration
NASA Astrophysics Data System (ADS)
Childs, Nicholas B.; Horányi, Mihály; Collette, Andrew
2013-11-01
We describe the principles of macroscopic charged particle detection in the laboratory and their connections to concepts taught in the physics classroom. Electrostatic dust accelerator systems, capable of launching charged dust grains at hypervelocities (1-100 km/s), are a critical tool for space exploration. Dust grains in space typically have large speeds relative to the probes or satellites that encounter them. Development and testing of instruments that look for dust in space therefore depends critically on the availability of fast, well-characterized dust grains in the laboratory. One challenge for the experimentalist is to precisely measure the speed and mass of laboratory dust particles without disturbing them. Detection systems currently in use exploit the well-known effect of image charge to register the passage of dust grains without changing their speed or mass. We describe the principles of image charge detection and provide a simple classroom demonstration of the technique using soup cans and pith balls.
Analysis of Indirect Emissions Benefits of Wind, Landfill Gas, and Municipal Solid Waste Generation
Techniques are introduced to calculate the hourly indirect emissions benefits of three types of green power resources: wind energy, municipal solid waste (MSW) combustion, and landfill gas (LFG) combustion. These techniques are applied to each of the U.S. EPA's eGRID subregions i...
Chavhan, Govind B; Alsabban, Zehour; Babyn, Paul S
2014-01-01
Diffusion-weighted (DW) imaging is an emerging technique in body imaging that provides indirect information about the microenvironment of tissues and lesions and helps detect, characterize, and follow up abnormalities. Two main challenges in the application of DW imaging to body imaging are the decreased signal-to-noise ratio of body tissues compared with neuronal tissues due to their shorter T2 relaxation time, and image degradation related to physiologic motion (eg, respiratory motion). Use of smaller b values and newer motion compensation techniques allow the evaluation of anatomic structures with DW imaging. DW imaging can be performed as a breath-hold sequence or a free-breathing sequence with or without respiratory triggering. Depending on the mobility of water molecules in their microenvironment, different normal tissues have different signals at DW imaging. Some normal tissues (eg, lymph nodes, spleen, ovarian and testicular parenchyma) are diffusion restricted, whereas others (eg, gallbladder, corpora cavernosa, endometrium, cartilage) show T2 shine-through. Epiphyses that contain fatty marrow and bone cortex appear dark on both DW images and apparent diffusion coefficient maps. Current and emerging applications of DW imaging in pediatric body imaging include tumor detection and characterization, assessment of therapy response and monitoring of tumors, noninvasive detection and grading of liver fibrosis and cirrhosis, detection of abscesses, and evaluation of inflammatory bowel disease. RSNA, 2014
Goldade, Mary Patricia; O'Brien, Wendy Pott
2014-01-01
At asbestos-contaminated sites, exposure assessment requires measurement of airborne asbestos concentrations; however, the choice of preparation steps employed in the analysis has been debated vigorously among members of the asbestos exposure and risk assessment communities for many years. This study finds that the choice of preparation technique used in estimating airborne amphibole asbestos exposures for risk assessment is generally not a significant source of uncertainty. Conventionally, the indirect preparation method has been less preferred by some because it is purported to result in false elevations in airborne asbestos concentrations, when compared to direct analysis of air filters. However, airborne asbestos sampling in non-occupational settings is challenging because non-asbestos particles can interfere with the asbestos measurements, sometimes necessitating analysis via indirect preparation. To evaluate whether exposure concentrations derived from direct versus indirect preparation techniques differed significantly, paired measurements of airborne Libby-type amphibole, prepared using both techniques, were compared. For the evaluation, 31 paired direct and indirect preparations originating from the same air filters were analyzed for Libby-type amphibole using transmission electron microscopy. On average, the total Libby-type amphibole airborne exposure concentration was 3.3 times higher for indirect preparation analysis than for its paired direct preparation analysis (standard deviation = 4.1), a difference which is not statistically significant (p = 0.12, two-tailed, Wilcoxon signed rank test). The results suggest that the magnitude of the difference may be larger for shorter particles. Overall, neither preparation technique (direct or indirect) preferentially generates more precise and unbiased data for airborne Libby-type amphibole concentration estimates. The indirect preparation method is reasonable for estimating Libby-type amphibole exposure and may be necessary given the challenges of sampling in environmental settings. Relative to the larger context of uncertainties inherent in the risk assessment process, uncertainties associated with the use of airborne Libby-type amphibole exposure measurements derived from indirect preparation analysis are low. Use of exposure measurements generated by either direct or indirect preparation analyses is reasonable to estimate Libby-type Amphibole exposures in a risk assessment.
Tabassum, Shahina; Al-Mahtab, Mamun; Nessa, Afzalun; Jahan, Munira; Shamim Kabir, Chowdhury Mohammad; Kamal, Mohammad; Cesar Aguilar, Julio
2015-01-01
Background Hepatitis B virus (HBV) infection has many faces. Precore and core promoter mutants resemble inactive carrier status. The identification of hepatitis B core antigen (HBcAg) in hepatocytes may have variable clinical significance. The present study was undertaken to detect HBcAg in chronic hepatitis B (CHB) patients and to assess the efficacy of detection system by indirect immunofluorescence (IIF) and indirect immunoperoxidase (IIP). Materials and methods The study was done in 70 chronic HBV-infected patients. Out of 70 patients, eight (11.4%) were hepatitis B e antigen (HBeAg) positive and 62 (88.57%) were HBeAg negative. Hepatitis B core antigen was detected by indirect immunofluorescence (IIF) and indirect immunoperoxidase (IIP) methods in liver tissue. Results All HBeAg positive patients expressed HBcAg by both IIF and IIP methods. Out of 62 patients with HBeAg-negative CHB, HBcAg was detected by IIF in 55 (88.7%) patients and by IIP in 51 (82.26%) patients. A positive relation among viral load and HBcAg detection was also found. This was more evident in the case of HBeAg negative patients and showed a positive relation with HBV DNA levels. Conclusion Hepatitis B core antigen can be detected using the IIF from formalin fixed paraffin block preparation and also by IIP method. This seems to reflect the magnitudes of HBV replication in CHB. How to cite this article Raihan R, Tabassum S, Al-Mahtab M, Nessa A, Jahan M, Kabir CMS, Kamal M, Aguilar JC. Hepatitis B Core Antigen in Hepatocytes of Chronic Hepatitis B: Comparison between Indirect Immunofluorescence and Immunoperoxidase Method. Euroasian J Hepato-Gastroenterol 2015;5(1):7-10. PMID:29201677
Practical diagnostic testing for human immunodeficiency virus.
Jackson, J B; Balfour, H H
1988-01-01
Since the discovery of human immunodeficiency virus (HIV) as the causative agent of acquired immunodeficiency syndrome in 1983, there has been a proliferation of diagnostic tests. These assays can be used to detect the presence of HIV antibody, HIV antigen, HIV ribonucleic and deoxyribonucleic acids, and HIV reverse transcriptase. Enzyme-linked immunosorbent assays, Western blot, radioimmunoprecipitation assays, indirect immunofluorescence assays, reverse transcriptase assays, and several molecular hybridization techniques are currently available. Enzyme-linked immunosorbent, Western blot, and indirect immunofluorescence assays for HIV antibody are very sensitive, specific, and adaptable to most laboratories. An enzyme-linked immunosorbent assay for HIV antigen is also readily adaptable to most laboratories and will be commercially available soon. While the other assays are more tedious, they are valuable confirmatory tests and are suitable for reference laboratories. The biohazards of performing HIV testing can be minimized with proper biosafety measures. Images PMID:3060241
Liu, Yong-Qiang; Yu, Hong
2016-08-01
Indirect ultraviolet detection was conducted in ultraviolet-absorption-agent-added mobile phase to complete the detection of the absence of ultraviolet absorption functional group in analytes. Compared with precolumn derivatization or postcolumn derivatization, this method can be widely used, has the advantages of simple operation and good linear relationship. Chromatographic separation of Li(+) , Na(+) , K(+) , and NH4 (+) was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid/organic solvent as the mobile phase, in which imidazolium ionic liquids acted as ultraviolet absorption reagent and eluting agent. The retention behaviors of four kinds of cations are discussed, and the mechanism of separation and detection are described. The main factors influencing the separation and detection were the background ultraviolet absorption reagent and the concentration of hydrogen ion in the ion chromatography-indirect ultraviolet detection. The successful separation and detection of Li(+) , Na(+) , K(+) , and NH4 (+) within 13 min was achieved using the selected chromatographic conditions, and the detection limits (S/N = 3) were 0.02, 0.11, 0.30, and 0.06 mg/L, respectively. A new separation and analysis method of alkali metal ions and ammonium by ion chromatography with indirect ultraviolet detection method was developed, and the application range of ionic liquid was expanded. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kumar Khanna, Vinod
2007-01-01
The current status and research trends of detection techniques for DNA-based analysis such as DNA finger printing, sequencing, biochips and allied fields are examined. An overview of main detectors is presented vis-à-vis these DNA operations. The biochip method is explained, the role of micro- and nanoelectronic technologies in biochip realization is highlighted, various optical and electrical detection principles employed in biochips are indicated, and the operational mechanisms of these detection devices are described. Although a diversity of biochips for diagnostic and therapeutic applications has been demonstrated in research laboratories worldwide, only some of these chips have entered the clinical market, and more chips are awaiting commercialization. The necessity of tagging is eliminated in refractive-index change based devices, but the basic flaw of indirect nature of most detection methodologies can only be overcome by generic and/or reagentless DNA sensors such as the conductance-based approach and the DNA-single electron transistor (DNA-SET) structure. Devices of the electrical detection-based category are expected to pave the pathway for the next-generation DNA chips. The review provides a comprehensive coverage of the detection technologies for DNA finger printing, sequencing and related techniques, encompassing a variety of methods from the primitive art to the state-of-the-art scenario as well as promising methods for the future.
Liu, Xiao; Zhu, Ling; Shi, Xiaohong; Xu, Zhiwen; Mei, Miao; Xu, Weiwei; Zhou, Yuancheng; Guo, Wanzhu; Wang, Xiaoyu
2012-12-01
The major epitope region of the glycoprotein B (gB) gene of the porcine cytomegalovirus (PCMV), with a length of 270 bp, was cloned and expressed in Escherichia coli Rosetta (DE3). The major gB epitope was detected using an agar gel precipitation and Western blot analysis with the polyclonal antibodies specific for the major epitope. An indirect-blocking enzyme-linked immunosorbent assay (ELISA) was developed using the expressed major gB epitope as a coating antigen for the detection of PCMV antibodies. The results of the tests show that the indirect-blocking ELISA has 98% specificity and 97.8% sensitivity. No cross-reactions were observed between the major gB epitope and the antibodies against other virus, which indicates that the gB epitope is specific for PCMV antibodies. The indirect-blocking ELISA is a highly specific, sensitive method for detecting anti-PCMV gB antibodies. Copyright © 2012 Elsevier B.V. All rights reserved.
Linear Phase Sharp Transition BPF to Detect Noninvasive Maternal and Fetal Heart Rate.
Marchon, Niyan; Naik, Gourish; Pai, K R
2018-01-01
Fetal heart rate (FHR) detection can be monitored using either direct fetal scalp electrode recording (invasive) or by indirect noninvasive technique. Weeks before delivery, the invasive method poses a risk factor to the fetus, while the latter provides accurate fetal ECG (FECG) information which can help diagnose fetal's well-being. Our technique employs variable order linear phase sharp transition (LPST) FIR band-pass filter which shows improved stopband attenuation at higher filter orders. The fetal frequency fiduciary edges form the band edges of the filter characterized by varying amounts of overlap of maternal ECG (MECG) spectrum. The one with the minimum maternal spectrum overlap was found to be optimum with no power line interference and maximum fetal heart beats being detected. The improved filtering is reflected in the enhancement of the performance of the fetal QRS detector (FQRS). The improvement has also occurred in fetal heart rate obtained using our algorithm which is in close agreement with the true reference (i.e., invasive fetal scalp ECG). The performance parameters of the FQRS detector such as sensitivity (Se), positive predictive value (PPV), and accuracy (F 1 ) were found to improve even for lower filter order. The same technique was extended to evaluate maternal QRS detector (MQRS) and found to yield satisfactory maternal heart rate (MHR) results.
Indirect Language Stimulation (ILS): AAC Techniques To Promote Communication Competence.
ERIC Educational Resources Information Center
Boose, Martha A.; Stinnett, Tessa
This report discusses the outcomes of a study that used indirect language stimulation techniques and modeling to encourage language development in a 5-year-old child with cerebral palsy. Initially, the student's communication system had very severe limitations. He used fewer than 10 spoken words which were unintelligible to most listeners. Both…
Doppler effect on indirect detection of dark matter using dark matter only simulations
Powell, Devon; Laha, Ranjan; Ng, Kenny C. Y.; ...
2017-03-15
Indirect detection of dark matter is a major avenue for discovery. However, baryonic backgrounds are diverse enough to mimic many possible signatures of dark matter. In this work, we study the newly proposed technique of dark matter velocity spectroscopy. The nonrotating dark matter halo and the Solar motion produce a distinct longitudinal dependence of the signal which is opposite in direction to that produced by baryons. Using collisionless dark matter only simulations of Milky Way like halos, we show that this new signature is robust and holds great promise. We develop mock observations by a high energy resolution x-ray spectrometermore » on a sounding rocket, the Micro-X experiment, to our test case, the 3.5 keV line. We show that by using six different pointings, Micro-X can exclude a constant line energy over various longitudes at ≥ 3σ. As a result, the halo triaxiality is an important effect, and it will typically reduce the significance of this signal. We emphasize that this new smoking gun in motion signature of dark matter is general and is applicable to any dark matter candidate which produces a sharp photon feature in annihilation or decay.« less
Doppler effect on indirect detection of dark matter using dark matter only simulations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Powell, Devon; Laha, Ranjan; Ng, Kenny C. Y.
Indirect detection of dark matter is a major avenue for discovery. However, baryonic backgrounds are diverse enough to mimic many possible signatures of dark matter. In this work, we study the newly proposed technique of dark matter velocity spectroscopy. The nonrotating dark matter halo and the Solar motion produce a distinct longitudinal dependence of the signal which is opposite in direction to that produced by baryons. Using collisionless dark matter only simulations of Milky Way like halos, we show that this new signature is robust and holds great promise. We develop mock observations by a high energy resolution x-ray spectrometermore » on a sounding rocket, the Micro-X experiment, to our test case, the 3.5 keV line. We show that by using six different pointings, Micro-X can exclude a constant line energy over various longitudes at ≥ 3σ. As a result, the halo triaxiality is an important effect, and it will typically reduce the significance of this signal. We emphasize that this new smoking gun in motion signature of dark matter is general and is applicable to any dark matter candidate which produces a sharp photon feature in annihilation or decay.« less
Detecting Damage in Ceramic Matrix Composites Using Electrical Resistance
NASA Technical Reports Server (NTRS)
Smith, Craig E.; Gyekenyesi, Andrew
2011-01-01
The majority of damage in SiC/SiC ceramic matrix composites subjected to monotonic tensile loads is in the form of distributed matrix cracks. These cracks initiate near stress concentrations, such as 90 deg fiber tows or large matrix pores and continue to accumulate with additional stress until matrix crack saturation is achieved. Such damage is difficult to detect with conventional nondestructive evaluation techniques (immersion ultrasonics, x-ray, etc.). Monitoring a specimen.s electrical resistance change provides an indirect approach for monitoring matrix crack density. Sylramic-iBN fiber- reinforced SiC composites with a melt infiltrated (MI) matrix were tensile tested at room temperature. Results showed an increase in resistance of more than 500% prior to fracture, which can be detected either in situ or post-damage. A relationship between resistance change and matrix crack density was also determined.
Detecting Cracks in Ceramic Matrix Composites by Electrical Resistance
NASA Technical Reports Server (NTRS)
Smith, Craig; Gyekenyesi, Andrew
2011-01-01
The majority of damage in SiC/SiC ceramic matrix composites subjected to monotonic tensile loads is in the form of distributed matrix cracks. These cracks initiate near stress concentrations, such as 90o fiber tows or large matrix pores and continue to accumulate with additional stress until matrix crack saturation is achieved. Such damage is difficult to detect with conventional nondestructive evaluation techniques (immersion ultrasonics, x-ray, etc.). Monitoring a specimen.s electrical resistance change provides an indirect approach for monitoring matrix crack density. Sylramic-iBN fiber- reinforced SiC composites with a melt infiltrated (MI) matrix were tensile tested at room temperature. Results showed an increase in resistance of more than 500% prior to fracture, which can be detected either in situ or post-damage. A relationship between resistance change and matrix crack density was also determined.
[Endemic syphillis in Upper Volta. A peculiar aspect of the epidemiological profile].
Bourdillon, F; Monjour, L; Druilhe, P; Fribourg-Blanc, A; Kyelem, J M; Chastang, C; Gentilini, M
1981-01-01
A seroimmunological survey was realised in Upper Volta using an indirect immunofluorescence technique. It showed that endemic syphilis also known as bejel is not exclusively encountered in Sahelian regions. So, in Kora village which is located in a savannah area prevalence was around 10.3%. The disease particularly affects males. Congenital syphilis is certainly exceptional for first cases of serological treponematosis were only detected after 5 years. Endemic syphilis distribution in microfocuses in the village area underlines that promiscuity acts as a contributing factor for contamination.
[Laboratory diagnosis of toxoplasmosis].
Strhársky, J; Mad'arová, L; Klement, C
2009-04-01
Under Central European climatic conditions, toxoplasmosis is one of the most common human parasitic diseases. A wide range of methods for both direct and indirect detection of the causative agent are currently available for the laboratory diagnosis of toxoplasmosis. The purpose of the article is to review the history of the discovery of the causative agent of toxoplasmosis and how laboratory diagnostic methods were developed and improved. The main emphasis is placed on current options in the diagnosis of Toxoplasma gondii, more precisely on the serodiagnosis and new trends in molecular biology-based techniques.
Majer-Baranyi, Krisztina; Zalán, Zsolt; Mörtl, Mária; Juracsek, Judit; Szendrő, István; Székács, András; Adányi, Nóra
2016-11-15
Optical waveguide lightmode spectroscopy (OWLS) technique has been applied to label-free detection of aflatoxin B1 in a competitive immunoassay format, with the aim to compare the analytical goodness of the developed OWLS immunosenor with HPLC and enzyme-linked immunosorbent assay (ELISA) methods for the detection of aflatoxin in spice paprika matrix. We have also assessed applicability of the QuEChERS method prior to ELISA measurements, and the results were compared to those obtained by traditional solvent extraction followed by immunoaffinity clean-up. The AFB1 content of sixty commercial spice paprika samples from different countries were measured with the developed and optimized OWLS immunosensor. Comparing the results from the indirect immunosensor to that obtained by HPLC or ELISA provided excellent correlation (with regression coefficients above 0.94) indicating that the competitive OWLS immunosensor has a potential for quick determination of aflatoxin B1 in paprika samples. Copyright © 2016 Elsevier Ltd. All rights reserved.
Li, Yan; Rashid, Azhar; Wang, Hongjie; Hu, Anyi; Lin, Lifeng; Yu, Chang-Ping; Chen, Meng; Sun, Qian
2018-08-15
Sulfamethoxazole (SMX) is a sulfonamide antibiotic, widely used as curative and preventive drug for human, animal, and aquaculture bacterial infections. Its residues have been ubiquitously detected in the surface waters and sediments. In the present study, SMX dissipation and kinetics was studied in the natural water samples from Jiulong River under simulated complex natural conditions as well as conditions to mimic various biotic and abiotic environmental conditions in isolation. Structural equation modeling (SEM) by employing partial least square technique in path coefficient analysis was used to investigate the direct and indirect contributions of different environmental factors in the natural attenuation of SMX. The model explained 81% of the variability in natural attenuation as a dependent variable under the influence of sole effects of direct photo-degradation, indirect photo-degradation, hydrolysis, microbial degradation and bacterial degradation. The results of SEM suggested that the direct and indirect photo-degradation were the major pathways in the SMX natural attenuation. However, other biotic and abiotic factors also play a mediatory role during the natural attenuation and other processes. Furthermore, the potential transformation products of SMX were identified and their toxicity was evaluated. Copyright © 2018 Elsevier B.V. All rights reserved.
Quenching behavior of molten pool with different strategies – A review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shrikant,, E-mail: 2014rmt9018@mnit.ac.in; Pandel, U.; Duchaniya, R. K.
After the major severe accident in nuclear reactor, there has been lot of concerns regarding long term core melt stabilization following a severe accident in nuclear reactors. Numerous strategies have been though for quenching and stabilization of core melt like top flooding, bottom flooding, indirect cooling, etc. However, the effectiveness of these schemes is yet to be determined properly, for which, lot of experiments are needed. Several experiments have been performed for coolability of melt pool under bottom flooding as well as for indirect cooling. Besides these tests are very scattered because they involve different simulants material initial temperatures andmore » masses of melt, which makes it very complex to judge the effectiveness of a particular technique and advantage over the other. In this review paper, a study has been carried on different cooling techniques of simulant materials with same mass. Three techniques have been compared here and the results are discussed. Under top flooding technique it took several hours to cool the melt under without decay heat condition. In bottom flooding technique was found to be the best technique among in indirect cooling technique, top flooded technique, and bottom flooded technique.« less
Costs of measuring leaf area index of corn
NASA Technical Reports Server (NTRS)
Daughtry, C. S. T.; Hollinger, S. E.
1984-01-01
The magnitude of plant-to-plant variability of leaf area of corn plants selected from uniform plots was examined and four representative methods for measuring leaf area index (LAI) were evaluated. The number of plants required and the relative costs for each sampling method were calculated to detect 10, 20, and 50% differences in LAI using 0.05 and 0.01 tests of significance and a 90% probability of success (beta = 0.1). The natural variability of leaf area per corn plant was nearly 10%. Additional variability or experimental error may be introduced by the measurement technique employed and by nonuniformity within the plot. Direct measurement of leaf area with an electronic area meter had the lowest CV, required that the fewest plants be sampled, but required approximately the same amount of time as the leaf area/weight ratio method to detect comparable differences. Indirect methods based on measurements of length and width of leaves required more plants but less total time than the direct method. Unless the coefficients for converting length and width to area are verified frequently, the indirect methods may be biased. When true differences in LAI among treatments exceed 50% of mean, all four methods are equal. The method of choice depends on the resources available, the differences to be detected, and what additional information, such as leaf weight or stalk weight, is also desired.
Indirect methods for reference interval determination - review and recommendations.
Jones, Graham R D; Haeckel, Rainer; Loh, Tze Ping; Sikaris, Ken; Streichert, Thomas; Katayev, Alex; Barth, Julian H; Ozarda, Yesim
2018-04-19
Reference intervals are a vital part of the information supplied by clinical laboratories to support interpretation of numerical pathology results such as are produced in clinical chemistry and hematology laboratories. The traditional method for establishing reference intervals, known as the direct approach, is based on collecting samples from members of a preselected reference population, making the measurements and then determining the intervals. An alternative approach is to perform analysis of results generated as part of routine pathology testing and using appropriate statistical techniques to determine reference intervals. This is known as the indirect approach. This paper from a working group of the International Federation of Clinical Chemistry (IFCC) Committee on Reference Intervals and Decision Limits (C-RIDL) aims to summarize current thinking on indirect approaches to reference intervals. The indirect approach has some major potential advantages compared with direct methods. The processes are faster, cheaper and do not involve patient inconvenience, discomfort or the risks associated with generating new patient health information. Indirect methods also use the same preanalytical and analytical techniques used for patient management and can provide very large numbers for assessment. Limitations to the indirect methods include possible effects of diseased subpopulations on the derived interval. The IFCC C-RIDL aims to encourage the use of indirect methods to establish and verify reference intervals, to promote publication of such intervals with clear explanation of the process used and also to support the development of improved statistical techniques for these studies.
Review of indirect detection of dark matter with neutrinos
NASA Astrophysics Data System (ADS)
Danninger, Matthias
2017-09-01
Dark Matter could be detected indirectly through the observation of neutrinos produced in dark matter self-annihilations or decays. Searches for such neutrino signals have resulted in stringent constraints on the dark matter self-annihilation cross section and the scattering cross section with matter. In recent years these searches have made significant progress in sensitivity through new search methodologies, new detection channels, and through the availability of rich datasets from neutrino telescopes and detectors, like IceCube, ANTARES, Super-Kamiokande, etc. We review recent experimental results and put them in context with respect to other direct and indirect dark matter searches. We also discuss prospects for discoveries at current and next generation neutrino detectors.
Yang, Li; Wang, Guobao; Qi, Jinyi
2016-04-01
Detecting cancerous lesions is a major clinical application of emission tomography. In a previous work, we studied penalized maximum-likelihood (PML) image reconstruction for lesion detection in static PET. Here we extend our theoretical analysis of static PET reconstruction to dynamic PET. We study both the conventional indirect reconstruction and direct reconstruction for Patlak parametric image estimation. In indirect reconstruction, Patlak parametric images are generated by first reconstructing a sequence of dynamic PET images, and then performing Patlak analysis on the time activity curves (TACs) pixel-by-pixel. In direct reconstruction, Patlak parametric images are estimated directly from raw sinogram data by incorporating the Patlak model into the image reconstruction procedure. PML reconstruction is used in both the indirect and direct reconstruction methods. We use a channelized Hotelling observer (CHO) to assess lesion detectability in Patlak parametric images. Simplified expressions for evaluating the lesion detectability have been derived and applied to the selection of the regularization parameter value to maximize detection performance. The proposed method is validated using computer-based Monte Carlo simulations. Good agreements between the theoretical predictions and the Monte Carlo results are observed. Both theoretical predictions and Monte Carlo simulation results show the benefit of the indirect and direct methods under optimized regularization parameters in dynamic PET reconstruction for lesion detection, when compared with the conventional static PET reconstruction.
USDA-ARS?s Scientific Manuscript database
An indirect capture model assay using colloidal Au nanoparticles is demonstrated for surface enhanced Raman scattering (SERS) spectroscopy detection of DNA. The sequence targeted for capture is derived from the West Nile Virus (WNV) RNA genome and was selected on the basis of exhibiting minimal seco...
Majeski, Stephanie A; Steffey, Michele A; Fuller, Mark; Hunt, Geraldine B; Mayhew, Philipp D; Pollard, Rachel E
2017-05-01
Sentinel lymph node mapping can help to direct surgical oncologic staging and metastatic disease detection in patients with complex lymphatic pathways. We hypothesized that indirect computed tomographic lymphography (ICTL) with a water-soluble iodinated contrast agent would successfully map lymphatic pathways of the iliosacral lymphatic center in dogs with anal sac gland carcinoma, providing a potential preoperative method for iliosacral sentinel lymph node identification in dogs. Thirteen adult dogs diagnosed with anal sac gland carcinoma were enrolled in this prospective, pilot study, and ICTL was performed via peritumoral contrast injection with serial caudal abdominal computed tomography scans for iliosacral sentinel lymph node identification. Technical and descriptive details for ICTL were recorded, including patient positioning, total contrast injection volume, timing of contrast visualization, and sentinel lymph nodes and lymphatic pathways identified. Indirect CT lymphography identified lymphatic pathways and sentinel lymph nodes in 12/13 cases (92%). Identified sentinel lymph nodes were ipsilateral to the anal sac gland carcinoma in 8/12 and contralateral to the anal sac gland carcinoma in 4/12 cases. Sacral, internal iliac, and medial iliac lymph nodes were identified as sentinel lymph nodes, and patterns were widely variable. Patient positioning and timing of imaging may impact successful sentinel lymph node identification. Positioning in supported sternal recumbency is recommended. Results indicate that ICTL may be a feasible technique for sentinel lymph node identification in dogs with anal sac gland carcinoma and offer preliminary data to drive further investigation of iliosacral lymphatic metastatic patterns using ICTL and sentinel lymph node biopsy. © 2017 American College of Veterinary Radiology.
Zorba, Yahya Orcun; Ilday, Nurcan Ozakar; Bayındır, Yusuf Ziya; Demirbuga, Sezer
2013-01-01
Objective: The aim of this study was to test the null hypothesis that different surface conditioning (etch and rinse and self-etch) and curing techniques (light cure/dual cure) had no effect on the shear bond strength of direct and indirect composite inlays. Materials and Methods: A total of 112 extracted human molar teeth were horizontally sectioned and randomly divided into two groups according to restoration technique (direct and indirect restorations). Each group was further subdivided into seven subgroups (n = 8) according to bonding agent (etch and rinse adhesives Scotchbond multi-purpose plus, All-Bond 3, Adper Single Bond and Prime Bond NT; and self-etch adhesives Clearfil Liner Bond, Futurabond DC and G bond). Indirect composites were cemented to dentin surfaces using dual-curing luting cement. Shear bond strength of specimens was tested using a Universal Testing Machine. Two samples from each subgroup were evaluated under Scanning electron microscopy to see the failing modes. Data was analyzed using independent sample t-tests and Tukey's tests. Results: Surface conditioning and curing of bonding agents were all found to have significant effects on shear bond strength (P < 0.05) of both direct and indirect composite inlays. With direct restoration, etch and rinse systems and dual-cured bonding agents yielded higher bond strengths than indirect restoration, self-etch systems and light-cured bonding agents. Conclusions: The results of the present study indicated that direct restoration to be a more reliable method than indirect restoration. Although etch and rinse bonding systems showed higher shear bond strength to dentin than self-etch systems, both systems can be safely used for the adhesion of direct as well as indirect restorations. PMID:24932118
Zorba, Yahya Orcun; Ilday, Nurcan Ozakar; Bayındır, Yusuf Ziya; Demirbuga, Sezer
2013-10-01
The aim of this study was to test the null hypothesis that different surface conditioning (etch and rinse and self-etch) and curing techniques (light cure/dual cure) had no effect on the shear bond strength of direct and indirect composite inlays. A total of 112 extracted human molar teeth were horizontally sectioned and randomly divided into two groups according to restoration technique (direct and indirect restorations). Each group was further subdivided into seven subgroups (n = 8) according to bonding agent (etch and rinse adhesives Scotchbond multi-purpose plus, All-Bond 3, Adper Single Bond and Prime Bond NT; and self-etch adhesives Clearfil Liner Bond, Futurabond DC and G bond). Indirect composites were cemented to dentin surfaces using dual-curing luting cement. Shear bond strength of specimens was tested using a Universal Testing Machine. Two samples from each subgroup were evaluated under Scanning electron microscopy to see the failing modes. Data was analyzed using independent sample t-tests and Tukey's tests. Surface conditioning and curing of bonding agents were all found to have significant effects on shear bond strength (P < 0.05) of both direct and indirect composite inlays. With direct restoration, etch and rinse systems and dual-cured bonding agents yielded higher bond strengths than indirect restoration, self-etch systems and light-cured bonding agents. The results of the present study indicated that direct restoration to be a more reliable method than indirect restoration. Although etch and rinse bonding systems showed higher shear bond strength to dentin than self-etch systems, both systems can be safely used for the adhesion of direct as well as indirect restorations.
NASA Astrophysics Data System (ADS)
Ornelas, Danielle; Hasan, Md.; Gonzalez, Oscar; Krishnan, Giri; Szu, Jenny I.; Myers, Timothy; Hirota, Koji; Bazhenov, Maxim; Binder, Devin K.; Park, Boris H.
2017-02-01
Electrophysiology has remained the gold standard of neural activity detection but its resolution and high susceptibility to noise and motion artifact limit its efficiency. Imaging techniques, including fMRI, intrinsic optical imaging, and diffuse optical imaging, have been used to detect neural activity, but rely on indirect measurements such as changes in blood flow. Fluorescence-based techniques, including genetically encoded indicators, are powerful techniques, but require introduction of an exogenous fluorophore. A more direct optical imaging technique is optical coherence tomography (OCT), a label-free, high resolution, and minimally invasive imaging technique that can produce depth-resolved cross-sectional and 3D images. In this study, we sought to examine non-vascular depth-dependent optical changes directly related to neural activity. We used an OCT system centered at 1310 nm to search for changes in an ex vivo brain slice preparation and an in vivo model during 4-AP induced seizure onset and propagation with respect to electrical recording. By utilizing Doppler OCT and the depth-dependency of the attenuation coefficient, we demonstrate the ability to locate and remove the optical effects of vasculature within the upper regions of the cortex from in vivo attenuation calculations. The results of this study show a non-vascular decrease in intensity and attenuation in ex vivo and in vivo seizure models, respectively. Regions exhibiting decreased optical changes show significant temporal correlation to regions of increased electrical activity during seizure. This study allows for a thorough and biologically relevant analysis of the optical signature of seizure activity both ex vivo and in vivo using OCT.
Herpes simplex keratitis in South India: clinico-virological correlation.
Pramod, N P; Rajendran, P; Kannan, K A; Thyagarajan, S P
1999-01-01
A retrospective cross-section study to analyze the prevalence of herpes simplex virus-induced keratitis (HSK) among 3,000 patients attending a corneal clinic in South India between 1995 and 1997, and to evaluate laboratory techniques for detecting HSK. The clinico-virological correlation was studied using herpes simplex virus (HSV) isolation on the Vero cell line, HSV-specific antigen detection by indirect immunofluorescence (IF) microscopy, and serum anti-HSV IgG quantitation, IgM estimation, and tear secretory IgA (sIgA) detection by ELISA. HSK had a prevalence of 7.8% (234 patients) in this study. A virological correlation could be obtained in 44.4% of the cases that had epithelial manifestations and in 14.8% of the cases that had only stromal disease. In 161 cases where both culture and IF microscopy were used, IF detected 27 cases (26.8%) more than cell culture. The difference in sensitivity between cell culture and IF was found to be statistically significant (McNemar's test, P < .05). An elevation in IgG titer was seen in 17 (30.4%) cases. IgM was detected in only 2 cases of the 62 (3.2%) analyzed. Of the 138 cases analyzed, sIgA was positive in 28 (20.3%) cases. A proved diagnosis could be made in 58% of cases when the specimen was collected during the first week after disease onset, and in only 5% when the time interval increased to 4 weeks. HSV antigen detection by indirect IF is a rapid and sensitive diagnostic tool for HSK. Tear secretory IgA (sIgA) is a specific marker for acute herpetic keratitis, and the detection of HSV-specific tear sIgA is a valuable adjunct to virus isolation and antigen detection in the laboratory diagnosis of HSK. For a successful diagnosis, the specimen should be collected as soon as possible after HSK onset.
NASA Astrophysics Data System (ADS)
Decho, Alan W.; Beckman, Erin M.; Chandler, G. Thomas; Kawaguchi, Tomohiro
2008-06-01
An indirect immunofluorescence approach was developed using semiconductor quantum dot nanocrystals to label and detect a specific bacterial serotype of the bacterial human pathogen Vibrio parahaemolyticus, attached to small marine animals (i.e. benthic harpacticoid copepods), which are suspected pathogen carriers. This photostable labeling method using nanotechnology will potentially allow specific serotypes of other bacterial pathogens to be detected with high sensitivity in a range of systems, and can be easily applied for sensitive detection to other Vibrio species such as Vibrio cholerae.
Sasaki, Makoto; Shibata, Eri; Tohyama, Koujiro; Kudo, Kohsuke; Endoh, Jin; Otsuka, Kotaro; Sakai, Akio
2008-11-19
By using high-resolution, conventional, and neuromelanin-sensitive magnetic resonance imaging techniques, we reviewed the normal anatomy of the nuclei consisting of monoamine neurons such as dopaminergic, noradrenergic, and serotoninergic neurons and noted the changes in these nuclei that occur in some degenerative and psychiatric disorders. Multimodal MR images can directly or indirectly help in identifying the substantia nigra, locus ceruleus, and raphe nuclei that contain monoamine neurons. Neuromelanin-sensitive magnetic resonance imaging can detect signal alterations in the substantia nigra pars compacta and/or locus ceruleus that occur in Parkinson's disease and psychiatric disorders such as depression and schizophrenia. This technique seems to be promising for the noninvasive evaluation of the pathological or functional changes in the monoamine system that occur in degenerative and psychiatric disorders.
A Homogeneous Time-Resolved Fluorescence Immunoassay Method for the Measurement of Compound W
Huang, Biao; Yu, Huixin; Bao, Jiandong; Zhang, Manda; Green, William L; Wu, Sing-Yung
2018-01-01
Objective: Using compound W (a 3,3′-diiodothyronine sulfate [T2S] immuno-crossreactive material)-specific polyclonal antibodies and homogeneous time-resolved fluorescence immunoassay assay techniques (AlphaLISA) to establish an indirect competitive compound W (ICW) quantitative detection method. Method: Photosensitive particles (donor beads) coated with compound W or T2S and rabbit anti-W antibody were incubated with biotinylated goat anti-rabbit antibody. This constitutes a detection system with streptavidin-coated acceptor particle. We have optimized the test conditions and evaluated the detection performance. Results: The sensitivity of the method was 5 pg/mL, and the detection range was 5 to 10 000 pg/mL. The intra-assay coefficient of variation averages <10% with stable reproducibility. Conclusions: The ICW-AlphaLISA shows good stability and high sensitivity and can measure a wide range of compound W levels in extracts of maternal serum samples. This may have clinical application to screen congenital hypothyroidism in utero. PMID:29449777
Blixenkrone-Møller, M
1989-09-01
Using an indirect immunofluorescence technique, the distribution of viral antigen in various tissues and blood mononuclear leukocytes was studied in wild mink, either vaccinated with an attenuated vaccine strain of canine distemper virus (CDV) or experimentally inoculated with the virulent Snyder-Hill strain of CDV. Viral antigen was detected in cells of the lymphoid system 6 to 12 days after vaccination. From 2 to 3 days after inoculation with the virulent strain, CDV antigen was demonstrated in cells of the lymphoid system and, during the incubation period, the antigen had spread to the epithelia and brain at days 6 and 12, respectively. In clinical cases of acute fatal canine distemper, the viral antigen was detected in a wide variety of tissues, including the cells of the lymphoid system, epithelial cells of skin, mucous membranes, lung, kidney, and cells of the CNS. The diagnostic importance of CDV antigen detection is discussed on the basis of these findings.
A Homogeneous Time-Resolved Fluorescence Immunoassay Method for the Measurement of Compound W.
Huang, Biao; Yu, Huixin; Bao, Jiandong; Zhang, Manda; Green, William L; Wu, Sing-Yung
2018-01-01
Using compound W (a 3,3'-diiodothyronine sulfate [T 2 S] immuno-crossreactive material)-specific polyclonal antibodies and homogeneous time-resolved fluorescence immunoassay assay techniques (AlphaLISA) to establish an indirect competitive compound W (ICW) quantitative detection method. Photosensitive particles (donor beads) coated with compound W or T 2 S and rabbit anti-W antibody were incubated with biotinylated goat anti-rabbit antibody. This constitutes a detection system with streptavidin-coated acceptor particle. We have optimized the test conditions and evaluated the detection performance. The sensitivity of the method was 5 pg/mL, and the detection range was 5 to 10 000 pg/mL. The intra-assay coefficient of variation averages <10% with stable reproducibility. The ICW-AlphaLISA shows good stability and high sensitivity and can measure a wide range of compound W levels in extracts of maternal serum samples. This may have clinical application to screen congenital hypothyroidism in utero.
Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore
2002-01-01
The apparatus and method provide techniques for effectively implementing alpha and/or beta and/or gamma monitoring of items or locations as desired. Indirect alpha monitoring by detecting ions generated by alpha emissions, in conjunction with beta and/or gamma monitoring is provided. The invention additionally provides for screening of items prior to alpha monitoring using beta and/or gamma monitoring, so as to ensure that the alpha monitoring apparatus is not contaminated by proceeding direct to alpha monitoring of a heavily contaminated item or location. The invention provides additional versatility in the emission forms which can be monitored, whilst maintaining accuracy and avoiding inadvertent contamination.
Autoantibodies in Autoimmune Hepatitis.
Muratori, Luigi; Deleonardi, Gaia; Lalanne, Claudine; Barbato, Erica; Tovoli, Alessandra; Libra, Alessia; Lenzi, Marco; Cassani, Fabio; Muratori, Paolo
2015-01-01
The detection of diagnostic autoantibodies such as antinuclear antibodies (ANA), anti-smooth muscle antibodies (SMA), anti-liver/kidney microsomal type 1 (anti-LKM1), anti-liver cytosol type 1 (anti-LC1) and anti-soluble liver antigen (anti-SLA) is historically associated with the diagnosis of autoimmune hepatitis. When autoimmune hepatitis is suspected, the detection of one or any combination of diagnostic autoantibodies, by indirect immunofluorescence or immuno-enzymatic techniques with recombinant antigens, is a pivotal step to reach a diagnostic score of probable or definite autoimmune hepatitis. Diagnostic autoantibodies (ANA, SMA, anti-LKM1, anti-LC1, anti-SLA) are a cornerstone in the diagnosis of autoimmune hepatitis. Other ancillary autoantibodies, associated with peculiar clinical correlations, appear to be assay-dependent and institution-specific, and validation studies are needed. © 2015 S. Karger AG, Basel.
Molecular inversion probe assay.
Absalan, Farnaz; Ronaghi, Mostafa
2007-01-01
We have described molecular inversion probe technologies for large-scale genetic analyses. This technique provides a comprehensive and powerful tool for the analysis of genetic variation and enables affordable, large-scale studies that will help uncover the genetic basis of complex disease and explain the individual variation in response to therapeutics. Major applications of the molecular inversion probes (MIP) technologies include targeted genotyping from focused regions to whole-genome studies, and allele quantification of genomic rearrangements. The MIP technology (used in the HapMap project) provides an efficient, scalable, and affordable way to score polymorphisms in case/control populations for genetic studies. The MIP technology provides the highest commercially available multiplexing levels and assay conversion rates for targeted genotyping. This enables more informative, genome-wide studies with either the functional (direct detection) approach or the indirect detection approach.
Basic analytical methods for identification of erythropoiesis-stimulating agents in doping control
NASA Astrophysics Data System (ADS)
Postnikov, P. V.; Krotov, G. I.; Efimova, Yu A.; Rodchenkov, G. M.
2016-02-01
The design of new erythropoiesis-stimulating agents for clinical use necessitates constant development of methods for detecting the abuse of these substances, which are prohibited under the World Anti-Doping Code and are included in the World Anti-Doping Agency (WADA) prohibited list. This review integrates and describes systematically the published data on the key methods currently used by WADA-accredited anti-doping laboratories around the world to detect the abuse of erythropoiesis-stimulating agents, including direct methods (various polyacrylamide gel electrophoresis techniques, enzyme-linked immunosorbent assay, membrane enzyme immunoassay and mass spectrometry) and indirect methods (athlete biological passport). Particular attention is given to promising approaches and investigations that can be used to control prohibited erythropoietins in the near future. The bibliography includes 122 references.
Wang, Yicun; Gao, Xiang; Zhi Gang, J U; Liu, Jingyuan; Dong, Shuai; Wang, Li
2013-01-01
The secreted aspartyl proteinases 2 (Sap2) of Candida albicans (C. albicans) is a potential marker of candididasis. It is a virulence factor associated with adherence and tissue invasion. In order to detect Sap2 in clinical sera, we developed an indirect competitive enzyme-linked immunosorbent assay (ELISA). Polyclonal antibodies were produced for Sap2 by injecting Sap2 into a New Zealand White inbred rabbit. They could be used at a dilution exceeding 1:1200 in an indirect ELISA, and detected Sap2 concentration up to 1 ng/mL. Of the 286 cancer serum samples tested, 16.8% were found as candidiasis. The test was simple and economical to perform and had a level of sensitivity for detection of low-titer positive sera; thus, it may be proven to be of value in epidemiological studies on candidiasis.
Makkaew, P; Miller, M; Cromar, N J; Fallowfield, H J
2017-04-01
This study investigated the volume of wastewater retained on the surface of three different varieties of lettuce, Iceberg, Cos, and Oak leaf, following submersion in wastewater of different microbial qualities (10, 10 2 , 10 3 , and 10 4 E. coli MPN/100 mL) as a surrogate method for estimation of contamination of spray-irrigated lettuce. Uniquely, Escherichia coli was enumerated, after submersion, on both the outer and inner leaves and in a composite sample of lettuce. E. coli were enumerated using two techniques. Firstly, from samples of leaves - the direct method. Secondly, using an indirect method, where the E. coli concentrations were estimated from the volume of wastewater retained by the lettuce and the E. coli concentration of the wastewater. The results showed that different varieties of lettuce retained significantly different volumes of wastewater (p < 0.01). No statistical differences (p > 0.01) were detected between E. coli counts obtained from different parts of lettuce, nor between the direct and indirect enumeration methods. Statistically significant linear relationships were derived relating the E. coli concentration of the wastewater in which the lettuces were submerged to the subsequent E. coli count on each variety the lettuce.
Methods of DNA methylation detection
NASA Technical Reports Server (NTRS)
Maki, Wusi Chen (Inventor); Filanoski, Brian John (Inventor); Mishra, Nirankar (Inventor); Rastogi, Shiva (Inventor)
2010-01-01
The present invention provides for methods of DNA methylation detection. The present invention provides for methods of generating and detecting specific electronic signals that report the methylation status of targeted DNA molecules in biological samples.Two methods are described, direct and indirect detection of methylated DNA molecules in a nano transistor based device. In the direct detection, methylated target DNA molecules are captured on the sensing surface resulting in changes in the electrical properties of a nano transistor. These changes generate detectable electronic signals. In the indirect detection, antibody-DNA conjugates are used to identify methylated DNA molecules. RNA signal molecules are generated through an in vitro transcription process. These RNA molecules are captured on the sensing surface change the electrical properties of nano transistor thereby generating detectable electronic signals.
Azeem, Rubeena Abdul; Sureshbabu, Nivedhitha Malli
2018-01-01
Composite resin, serves as esthetic alternative to amalgam and cast restorations. Posterior teeth can be restored using direct or indirect composite restorations. The selection between direct and indirect technique is a clinically challenging decision-making process. Most important influencing factor is the amount of remaining tooth substance. The aim of this systematic review was to compare the clinical performance of direct versus indirect composite restorations in posterior teeth. The databases searched included PubMed CENTRAL (until July 2015), Medline, and Cochrane Database of Systematic Reviews. The bibliographies of clinical studies and reviews identified in the electronic search were analyzed to identify studies which were published outside the electronically searched journals. The primary outcome measure was evaluation of the survival of direct and indirect composite restorations in posterior teeth. This review included thirteen studies in which clinical performance of various types of direct and indirect composite restorations in posterior teeth were compared. Out of the thirteen studies which were included seven studies had a high risk of bias and five studies had a moderate risk of bias. One study having a low risk of bias, concluded that there was no significant difference between direct and indirect technique. However, the available evidence revealed inconclusive results. Further research should focus on randomized controlled trials with long term follow-up to give concrete evidence on the clinical performce of direct and indirect composite restorations.
Laborde, Juan M; Sguazza, Guillermo H; Fuentealba, Nadia A; Corva, Santiago G; Carbone, Cecilia; Galosi, Cecilia M
In this study we developed an indirect ELISA to detect antibodies against Minute Virus of Mice (MVM) using an antigen produced from BHK-21 cells infected with a prototype strain of the virus. The optimal antigen concentration and serum dilutions were established. In order to analyze variability in the laboratory, reproducibility and repeatability within and between plates were determined. Then, a panel of 460 sera from conventional facilities and previously classified as positive or negative by the indirect fluorescent antibody assay was analyzed. The cutoff value was determined by a receiver operating characteristic (ROC) curve. The results of the indirect ELISA were compared with those of the indirect fluorescent antibody assay. The ELISA assay showed 100% sensitivity and 99% specificity. ELISA is a useful tool to be developed in standard virology laboratories and can be used for screening animals faster than the traditional indirect fluorescent antibody assay. Copyright © 2017 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.
Automated indirect immunofluorescence evaluation of antinuclear autoantibodies on HEp-2 cells.
Voigt, Jörn; Krause, Christopher; Rohwäder, Edda; Saschenbrecker, Sandra; Hahn, Melanie; Danckwardt, Maick; Feirer, Christian; Ens, Konstantin; Fechner, Kai; Barth, Erhardt; Martinetz, Thomas; Stöcker, Winfried
2012-01-01
Indirect immunofluorescence (IIF) on human epithelial (HEp-2) cells is considered as the gold standard screening method for the detection of antinuclear autoantibodies (ANA). However, in terms of automation and standardization, it has not been able to keep pace with most other analytical techniques used in diagnostic laboratories. Although there are already some automation solutions for IIF incubation in the market, the automation of result evaluation is still in its infancy. Therefore, the EUROPattern Suite has been developed as a comprehensive automated processing and interpretation system for standardized and efficient ANA detection by HEp-2 cell-based IIF. In this study, the automated pattern recognition was compared to conventional visual interpretation in a total of 351 sera. In the discrimination of positive from negative samples, concordant results between visual and automated evaluation were obtained for 349 sera (99.4%, kappa = 0.984). The system missed out none of the 272 antibody-positive samples and identified 77 out of 79 visually negative samples (analytical sensitivity/specificity: 100%/97.5%). Moreover, 94.0% of all main antibody patterns were recognized correctly by the software. Owing to its performance characteristics, EUROPattern enables fast, objective, and economic IIF ANA analysis and has the potential to reduce intra- and interlaboratory variability.
Patel, Binay; Watanabe, Masashi
2014-02-01
Scanning transmission electron microscopy in scanning electron microscopy (STEM-in-SEM) is a convenient technique for soft materials characterization. Various specimen-holder geometries and detector arrangements have been used for bright-field (BF) STEM-in-SEM imaging. In this study, to further the characterization potential of STEM-IN-SEM, a new specimen holder has been developed to facilitate direct detection of BF signals and indirect detection of dark-field (DF) signals without the need for substantial instrument modification. DF imaging is conducted with the use of a gold (Au)-coated copper (Cu) plate attached to the specimen holder which directs highly scattered transmitted electrons to an off-axis yttrium-aluminum-garnet (YAG) detector. A hole in the copper plate allows for BF imaging with a transmission electron (TE) detector. The inclusion of an Au-coated Cu plate enhanced DF signal intensity. Experiments validating the acquisition of true DF signals revealed that atomic number (Z) contrast may be achieved for materials with large lattice spacing. However, materials with small lattice spacing still exhibit diffraction contrast effects in this approach. The calculated theoretical fine probe size is 1.8 nm. At 30 kV, in this indirect approach, DF spatial resolution is limited to 3.2 nm as confirmed experimentally.
Automated Indirect Immunofluorescence Evaluation of Antinuclear Autoantibodies on HEp-2 Cells
Voigt, Jörn; Krause, Christopher; Rohwäder, Edda; Saschenbrecker, Sandra; Hahn, Melanie; Danckwardt, Maick; Feirer, Christian; Ens, Konstantin; Fechner, Kai; Barth, Erhardt; Martinetz, Thomas; Stöcker, Winfried
2012-01-01
Indirect immunofluorescence (IIF) on human epithelial (HEp-2) cells is considered as the gold standard screening method for the detection of antinuclear autoantibodies (ANA). However, in terms of automation and standardization, it has not been able to keep pace with most other analytical techniques used in diagnostic laboratories. Although there are already some automation solutions for IIF incubation in the market, the automation of result evaluation is still in its infancy. Therefore, the EUROPattern Suite has been developed as a comprehensive automated processing and interpretation system for standardized and efficient ANA detection by HEp-2 cell-based IIF. In this study, the automated pattern recognition was compared to conventional visual interpretation in a total of 351 sera. In the discrimination of positive from negative samples, concordant results between visual and automated evaluation were obtained for 349 sera (99.4%, kappa = 0.984). The system missed out none of the 272 antibody-positive samples and identified 77 out of 79 visually negative samples (analytical sensitivity/specificity: 100%/97.5%). Moreover, 94.0% of all main antibody patterns were recognized correctly by the software. Owing to its performance characteristics, EUROPattern enables fast, objective, and economic IIF ANA analysis and has the potential to reduce intra- and interlaboratory variability. PMID:23251220
Chiba, Yasutaka
2014-01-01
Questions of mediation are often of interest in reasoning about mechanisms, and methods have been developed to address these questions. However, these methods make strong assumptions about the absence of confounding. Even if exposure is randomized, there may be mediator-outcome confounding variables. Inference about direct and indirect effects is particularly challenging if these mediator-outcome confounders are affected by the exposure because in this case these effects are not identified irrespective of whether data is available on these exposure-induced mediator-outcome confounders. In this paper, we provide a sensitivity analysis technique for natural direct and indirect effects that is applicable even if there are mediator-outcome confounders affected by the exposure. We give techniques for both the difference and risk ratio scales and compare the technique to other possible approaches. PMID:25580387
NASA Astrophysics Data System (ADS)
Skaggs, Rhonda Lynn
A new cartridge sampling and derivatization technique was developed for the determination of aldehydes and ketones in air that allows measurement of sub-ppbv mixing ratios using sampling times of ten minutes or less. This thesis describes the development and evaluation of the analytical technique and a preliminary survey of carbonyl emissions from wounded plants. Also described is the development of an analytical technique for the measurement of argon, a passive biogeochemical tracer. Carbonyl compounds are sampled onto high pressure cartridges containing particles coated with 2,4- dinitrophenylhydrazine where they react to form hydrazones. The entire sample is eluted and transferred to the head of a high performance liquid chromatograph (HPLC) for separation and detection by UV absorbance. The method is demonstrated to be approximately two orders of magnitude more sensitive than the conventional DNPH technique in which only a small fraction of the hydrazones are transferred to the column. It was found that two calibration methods gave different sensitivities resulting from the formation of different ratios of syn and anti isomers of the hydrazones. These results suggest that many measurements of atmospheric carbonyls reported in the literature may have significant errors if syn and anti isomers were unresolved. A chamber method was used to study the emissions of aldehydes and ketones from a variety of wounded plants. 2-E-Hexenal and acetaldehyde were detected in the wound response emissions of all six plants examined. Enhanced concentrations of methylethyl ketone (MEK) in addition to acetaldehyde and 2-E-hexenal were detected following wounding of clover, and the emissions of 2-E-hexenal and MEK in response to wounding displayed different temporal release patterns. A novel application of a commercial photionization detector for the quantification of argon is described and applied to the headspace analysis of water. Argon is measured indirectly by its effect on an ionizable gas (nitric oxide) present in the detection cell. By varying the amount of nitric oxide added to the detection cell, two modes of operation were demonstrated: a competitive absorbance mode and a Penning ionization mode. Optimized Penning ionization detection with a nitric oxide concentration of ~940 ppmv was used to analyze air and the headspace of water samples. The limit of detection was determined to be 14 pmol Ar s-1.
Indirect fabrication of multiple post-and-core patterns with a vinyl polysiloxane matrix.
Sabbak, Sahar Asaad
2002-11-01
In the described technique, a vinyl polysiloxane material is used as a matrix for the indirect fabrication of multiple custom-cast posts and cores. The matrix technique enables the clinician to fabricate multiple posts and cores in a short period of time. The form, harmony, and common axis of preparation for all cores are well controlled before the definitive crown/fixed partial denture restorations are fabricated. Oral tissues are not exposed to the heat of polymerization or the excess monomer of the resin material when this technique is used.
[Individual indirect bonding technique (IIBT) using set-up model].
Kyung, H M
1989-01-01
There has been much progress in Edgewise Appliance since E.H. Angle. One of the most important procedures in edgewise appliance is correct bracket position. Not only conventional edgewise appliance but also straight wire appliance & lingual appliance cannot be used more effectively unless the bracket position is accurate. Improper bracket positioning may reveal much problems during treatment, especially in finishing state. It may require either rebonding after the removal of the malpositioned bracket or the greater number of arch wire and the more complex wire bending, causing much difficulty in performing effective treatments. This made me invent Individual Indirect Bonding Technique with the use of multi-purpose set-up model in order to determine a correct and objective bracket position according to individual patients. This technique is more accurate than former indirect bonding techniques in bracket positioning, because it decides the bracket position on a set-up model which has produced to have the occlusal relationship the clinician desired. This technique is especially effective in straight wire appliance and lingual appliance in which the correct bracket positioning is indispensible.
Tognon, Mauro; Corallini, Alfredo; Manfrini, Marco; Taronna, Angelo; Butel, Janet S.; Pietrobon, Silvia; Trevisiol, Lorenzo; Bononi, Ilaria; Vaccher, Emanuela; Barbanti-Brodano, Giuseppe; Martini, Fernanda; Mazzoni, Elisa
2016-01-01
Simian Virus 40, experimentally assayed in vitro in different animal and human cells and in vivo in rodents, was classified as a small DNA tumor virus. In previous studies, many groups identified Simian Virus 40 sequences in healthy individuals and cancer patients using PCR techniques, whereas others failed to detect the viral sequences in human specimens. These conflicting results prompted us to develop a novel indirect ELISA with synthetic peptides, mimicking Simian Virus 40 capsid viral protein antigens, named mimotopes. This immunologic assay allowed us to investigate the presence of serum antibodies against Simian Virus 40 and to verify whether Simian Virus 40 is circulating in humans. In this investigation two mimotopes from Simian Virus 40 large T antigen, the viral replication protein and oncoprotein, were employed to analyze for specific reactions to human sera antibodies. This indirect ELISA with synthetic peptides from Simian Virus 40 large T antigen was used to assay a new collection of serum samples from healthy subjects. This novel assay revealed that serum antibodies against Simian Virus 40 large T antigen mimotopes are detectable, at low titer, in healthy subjects aged from 18–65 years old. The overall prevalence of reactivity with the two Simian Virus 40 large T antigen peptides was 20%. This new ELISA with two mimotopes of the early viral regions is able to detect in a specific manner Simian Virus 40 large T antigen-antibody responses. PMID:26731525
Colton, J S; Erickson, S D; Smith, T J; Watt, R K
2014-04-04
Ferritin is a protein nano-cage that encapsulates minerals inside an 8 nm cavity. Previous band gap measurements on the native mineral, ferrihydrite, have reported gaps as low as 1.0 eV and as high as 2.5-3.5 eV. To resolve this discrepancy we have used optical absorption spectroscopy, a well-established technique for measuring both direct and indirect band gaps. Our studies included controls on the protein nano-cage, ferritin with the native ferrihydrite mineral, and ferritin with reconstituted ferrihydrite cores of different sizes. We report measurements of an indirect band gap for native ferritin of 2.140 ± 0.015 eV (579.7 nm), with a direct transition appearing at 3.053 ± 0.005 eV (406.1 nm). We also see evidence of a defect-related state having a binding energy of 0.220 ± 0.010 eV . Reconstituted ferrihydrite minerals of different sizes were also studied and showed band gap energies which increased with decreasing size due to quantum confinement effects. Molecules that interact with the surface of the mineral core also demonstrated a small influence following trends in ligand field theory, altering the native mineral's band gap up to 0.035 eV.
Espinheira Gomes, Filipe; Ledbetter, Eric
2018-05-11
To describe an indirect funduscopy imaging technique for dogs and cats using low cost and widely available equipment: a smartphone, a three-dimensional (3D) printed indirect lens adapter, and a 40 diopters (D) indirect ophthalmoscopy lens. Fundus videography was performed in dogs and cats using a 40D indirect ophthalmoscopy lens and a smartphone fitted with a 3D printed indirect lens adapter. All animals were pharmacologically dilated with topical tropicamide 1% solution. Eyelid opening and video recording were performed using standard binocular indirect ophthalmoscopy technique. All videos were uploaded to a computer, and still images were selected and acquired for archiving purposes. Fundic images were manipulated to represent the true anatomy of the fundus. It was possible to promptly obtain good quality images from normal and diseased retinas using the nonpatented 3D printed, lens adapter for a smartphone. Fundic imaging using a smartphone can be performed with minimal investment. This simple imaging modality can be used by veterinary ophthalmologists and general practitioners to acquire, archive, and share images of the retina. The quality of images obtained will likely improve with developments in smartphone camera software and hardware. © 2018 American College of Veterinary Ophthalmologists.
Indirect effects in community ecology: Their definition, study and importance.
Strauss, S Y
1991-07-01
The diversity of indirect interactions that can occur within communities is large. Recent research on indirect interactions is scattered in the literature under numerous labels. The definition of indirect effects is an important aspect of their study, and clarifies some of the subtle differences among indirect effects found in natural communities. Choosing which species to study, how to manipulate species and for what duration, which attributes to measure and, finally, which analytical techniques to use are all problems facing the community ecologist. Ultimately, we are striving for the best means of determining the relative importance of direct and indirect effects in structuring communities. Copyright © 1991. Published by Elsevier Ltd.
Computer-based detection of diabetes retinopathy stages using digital fundus images.
Acharya, U R; Lim, C M; Ng, E Y K; Chee, C; Tamura, T
2009-07-01
Diabetes mellitus is a heterogeneous clinical syndrome characterized by hyperglycaemia and the long-term complications are retinopathy, neuropathy, nephropathy, and cardiomyopathy. It is a leading cause of blindness. Diabetic retinopathy is the progressive pathological alterations in the retinal microvasculature, leading to areas of retinal nonperfusion, increased vascular permeability, and the pathological proliferation of retinal vessels. Hence, it is beneficial to have regular cost-effective eye screening for diabetes subjects. Nowadays, different stages of diabetes retinopathy are detected by retinal examination using indirect biomicroscopy by senior ophthalmologists. In this work, morphological image processing and support vector machine (SVM) techniques were used for the automatic diagnosis of eye health. In this study, 331 fundus images were analysed. Five groups were identified: normal retina, mild non-proliferative diabetic retinopathy, moderate non-proliferative diabetic retinopathy, severe non-proliferative diabetic retinopathy, and proliferative diabetic retinopathy. Four salient features blood vessels, microaneurysms, exudates, and haemorrhages were extracted from the raw images using image-processing techniques and fed to the SVM for classification. A sensitivity of more than 82 per cent and specificity of 86 per cent was demonstrated for the system developed.
NASA Astrophysics Data System (ADS)
Ornelas, Danielle; Hasan, Md.; Gonzalez, Oscar; Krishnan, Giri; Szu, Jenny I.; Myers, Timothy; Hirota, Koji; Bazhenov, Maxim; Binder, Devin K.; Park, Boris H.
2017-02-01
Epilepsy is a chronic neurological disorder characterized by recurrent and unpredictable seizures. Electrophysiology has remained the gold standard of neural activity detection but its resolution and high susceptibility to noise and motion artifact limit its efficiency. Optical imaging techniques, including fMRI, intrinsic optical imaging, and diffuse optical imaging, have also been used to detect neural activity yet these techniques rely on the indirect measurement of changes in blood flow. A more direct optical imaging technique is optical coherence tomography (OCT), a label-free, high resolution, and minimally invasive imaging technique that can produce depth-resolved cross-sectional and 3D images. In this study, OCT was used to detect non-vascular depth-dependent optical changes in cortical tissue during 4-aminopyridine (4-AP) induced seizure onset. Calculations of localized optical attenuation coefficient (µ) allow for the assessment of depth-resolved volumetric optical changes in seizure induced cortical tissue. By utilizing the depth-dependency of the attenuation coefficient, we demonstrate the ability to locate and remove the optical effects of vasculature within the upper regions of the cortex on the attenuation calculations of cortical tissue in vivo. The results of this study reveal a significant depth-dependent decrease in attenuation coefficient of nonvascular cortical tissue both ex vivo and in vivo. Regions exhibiting decreased attenuation coefficient show significant temporal correlation to regions of increased electrical activity during seizure onset and progression. This study allows for a more thorough and biologically relevant analysis of the optical signature of seizure activity in vivo using OCT.
Hall, Patrick G.; Krieg, Noel R.
1984-01-01
An indirect immunoperoxidase stain was used to demonstrate by electron microscopy that an antigenic difference exists between the polar flagellum and the lateral flagella of Azospirillum brasilense ATCC 29145. Images PMID:16346482
Studying planet populations with Einstein's blip.
Dominik, Martin
2010-08-13
Although Einstein originally judged that 'there is no great chance of observing this phenomenon', the 'most curious effect' of the bending of starlight by the gravity of intervening foreground stars--now commonly referred to as 'gravitational microlensing'--has become one of the successfully applied techniques to detect planets orbiting stars other than the Sun, while being quite unlike any other. With more than 400 extra-solar planets known altogether, the discovery of a true sibling of our home planet seems to have become simply a question of time. However, in order to properly understand the origin of Earth, carrying all its various life forms, models of planet formation and orbital evolution need to be brought into agreement with the statistics of the full variety of planets like Earth and unlike Earth. Given the complementarity of the currently applied planet detection techniques, a comprehensive picture will only arise from a combination of their respective findings. Gravitational microlensing favours a range of orbital separations that covers planets whose orbital periods are too long to allow detection by other indirect techniques, but which are still too close to their host star to be detected by means of their emitted or reflected light. Rather than being limited to the Solar neighbourhood, a unique opportunity is provided for inferring a census of planets orbiting stars belonging to two distinct populations within the Milky Way, with a sensitivity not only reaching down to Earth mass, but even below, with ground-based observations. The capabilities of gravitational microlensing extend even to obtaining evidence of a planet orbiting a star in another galaxy.
Quantitation of dissolved gas content in emulsions and in blood using mass spectrometric detection
Grimley, Everett; Turner, Nicole; Newell, Clayton; Simpkins, Cuthbert; Rodriguez, Juan
2011-01-01
Quantitation of dissolved gases in blood or in other biological media is essential for understanding the dynamics of metabolic processes. Current detection techniques, while enabling rapid and convenient assessment of dissolved gases, provide only direct information on the partial pressure of gases dissolved in the aqueous fraction of the fluid. The more relevant quantity known as gas content, which refers to the total amount of the gas in all fractions of the sample, can be inferred from those partial pressures, but only indirectly through mathematical modeling. Here we describe a simple mass spectrometric technique for rapid and direct quantitation of gas content for a wide range of gases. The technique is based on a mass spectrometer detector that continuously monitors gases that are rapidly extracted from samples injected into a purge vessel. The accuracy and sample processing speed of the system is demonstrated with experiments that reproduce within minutes literature values for the solubility of various gases in water. The capability of the technique is further demonstrated through accurate determination of O2 content in a lipid emulsion and in whole blood, using as little as 20 μL of sample. The approach to gas content quantitation described here should greatly expand the range of animals and conditions that may be used in studies of metabolic gas exchange, and facilitate the development of artificial oxygen carriers and resuscitation fluids. PMID:21497566
Indirect Detection Analysis: Wino Dark Matter Case Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hryczuk, Andrzej; Cholis, Ilias; Iengo, Roberto
2014-07-15
We perform a multichannel analysis of the indirect signals for the Wino Dark Matter, including one-loop electroweak and Sommerfeld enhancement corrections. We derive limits from cosmic ray antiprotons and positrons, from continuum galactic and extragalactic diffuse γ-ray spectra, from the absence of γ-ray line features at the galactic center above 500 GeV in energy, from γ-rays toward nearby dwarf spheroidal galaxies and galaxy clusters, and from CMB power-spectra. Additionally, we show the future prospects for neutrino observations toward the inner Galaxy and from antideuteron searches. For each of these indirect detection probes we include and discuss the relevance of themore » most important astrophysical uncertainties that can impact the strength of the derived limits. We find that the Wino as a dark matter candidate is excluded in the mass range bellow simeq 800 GeV from antiprotons and between 1.8 and 3.5 TeV from the absence of a γ-ray line feature toward the galactic center. Limits from other indirect detection probes confirm the main bulk of the excluded mass ranges.« less
Saijo, Masayuki; Qing, Tang; Niikura, Masahiro; Maeda, Akihiko; Ikegami, Tetsuro; Sakai, Koji; Prehaud, Christophe; Kurane, Ichiro; Morikawa, Shigeru
2002-01-01
A HeLa cell line continuously expressing recombinant nucleoprotein (rNP) of the Crimean-Congo hemorrhagic fever virus (CCHFV) was established by transfection with an expression vector containing the cDNA of CCHFV NP (pKS336-CCHFV-NP). These cells were used as antigens for indirect immunofluorescence (IF) to detect immunoglobulin G antibodies to CCHFV. The sensitivity and specificity of this IF technique were examined by using serum samples and were compared to those of the IF technique using CCHFV-infected Vero E6 cells (authentic antigen). Staining of the CCHFV rNP expressed in HeLa cells showed a unique granular pattern similar to that of CCHFV-infected Vero E6 cells. Positive staining could easily be distinguished from a negative result. All 13 serum samples determined to be positive by using the authentic antigen were also determined to be positive by using CCHFV rNP-expressing HeLa cells (recombinant antigen). The 108 serum samples determined to be negative by using the authentic antigen were also determined to be negative by using the recombinant antigen. Thus, both the sensitivity and the specificity of this IF technique were 100% compared to the IF with authentic antigen. The novel IF technique using CCHFV rNP-expressing HeLa cells can be used not only for diagnosis of CCHF but also for epidemiological studies on CCHFV infections. PMID:11825944
Detectability of molecular signatures in the atmospheres of Giant and Terrestrial Exoplanets
NASA Astrophysics Data System (ADS)
Tinetti, G. T.; Vidal-Madjar, A.; Lecavelier Des Etangs, A.; Ehrenreich, D.; Liang, M. C.; Yung, Y.
In the past decade over 160 planets orbiting other stars extrasolar planets were discovered using indirect detection techniques The known sample is constrained by the currently achievable detection techniques which are more sensitive to larger worlds To extend the detection ability down to Earth-sized planets both the European Space Agency ESA and National Aeronautics and Space Administration NASA are developing large and technologically challenging space-borne observatories The first of these missions is due for launch as early as 2015 and will provide our first opportunity to spectroscopically study the global characteristics of Earth-like planets beyond our solar system to search for signs of habitability and life Almost a decade in advance to the launch of ESA-Darwin or NASA-Terrestrial Planet Finders most recent observations of primary and secondary eclipses with Hubble Space Telescope and Spitzer of transiting extrasolar giant planets EGPs Charbonneau et al 2002 2005 Vidal-Madjar et al 2003 2004 Deming et al 2005 suggest that emitted and transmission spectra of EGPs can be used to infer many properties of their atmospheres and internal structure including chemical element abundances hydrodynamic escape cloud heights temperature-pressure profiles density composition and evolution The next generation of space telescopes James Webb Space Telescope JWST will have the capability of acquiring more precise spectra in the visible and infrared of these extrasolar worlds The ultimate extension of such searches will be to
GRE T2∗-Weighted MRI: Principles and Clinical Applications
Tang, Meng Yue; Chen, Tian Wu; Zhang, Xiao Ming; Huang, Xiao Hua
2014-01-01
The sequence of a multiecho gradient recalled echo (GRE) T2*-weighted imaging (T2*WI) is a relatively new magnetic resonance imaging (MRI) technique. In contrast to T2 relaxation, which acquires a spin echo signal, T2* relaxation acquires a gradient echo signal. The sequence of a GRE T2*WI requires high uniformity of the magnetic field. GRE T2*WI can detect the smallest changes in uniformity in the magnetic field and can improve the rate of small lesion detection. In addition, the T2* value can indirectly reflect changes in tissue biochemical components. Moreover, it can be used for the early diagnosis and quantitative diagnosis of some diseases. This paper reviews the principles and clinical applications as well as the advantages and disadvantages of GRE T2*WI. PMID:24987676
NASA Astrophysics Data System (ADS)
Ibarra-Castanedo, Clemente; Sfarra, Stefano; Klein, Matthieu; Maldague, Xavier
2017-05-01
The experimental results from infrared thermography surveys over two buildings externally exposed walls are presented. Data acquisition was performed on a static configuration by recording direct and indirect solar loading during several days and was processed using advanced signal processing techniques in order to increase signal-to-noise ratio and signature contrast of the elements of interest. It is demonstrated that it is possible to detect the thermal signature of large internal structures as well as surface features under such thermographic scenarios. Results from a long-wave microbolometer compared favorably to those from a mid-wave cooled infrared camera for the detection of large subsurface features from unprocessed images. In both cases, however, advanced signal processing greatly improved contrast of the internal features.
Erdoğan, Zeynep; Silov, Güler; Özdal, Ayşegül; Turhal, Özgül
2013-01-01
Myocardial perfusion imaging (MPI) with technetium-99m sestamibi (Tc-99m MIBI) is considered a diagnostic technique that is widely used for the investigation of suspected coronary artery disease. Incidental inspection of an extracardiac activity is indirect, but important marker, which can identify a potentially treatable non-coronary cause for chest pain that may mimic cardiac symptoms. Here, we present an illustrative case in which significant enterogastroesophageal reflux of Tc-99m MIBI occurred during the cardiac imaging following prompt hepatobiliary clearance. Because, there was normal myocardial perfusion on MPI, presence of gastroesophageal reflux (GER) on GER scintigraphy and detection of mild inflammation with pathologically confirmed hyperplastic polyp by endoscopy, in view of the above findings we concluded that the probable cause of chest pain was reflux. PMID:24019679
EDITORIAL: Focus on Dark Matter and Particle Physics
NASA Astrophysics Data System (ADS)
Aprile, Elena; Profumo, Stefano
2009-10-01
The quest for the nature of dark matter has reached a historical point in time, with several different and complementary experiments on the verge of conclusively exploring large portions of the parameter space of the most theoretically compelling particle dark matter models. This focus issue on dark matter and particle physics brings together a broad selection of invited articles from the leading experimental and theoretical groups in the field. The leitmotif of the collection is the need for a multi-faceted search strategy that includes complementary experimental and theoretical techniques with the common goal of a sound understanding of the fundamental particle physical nature of dark matter. These include theoretical modelling, high-energy colliders and direct and indirect searches. We are confident that the works collected here present the state of the art of this rapidly changing field and will be of interest to both experts in the topic of dark matter as well as to those new to this exciting field. Focus on Dark Matter and Particle Physics Contents DARK MATTER AND ASTROPHYSICS Scintillator-based detectors for dark matter searches I S K Kim, H J Kim and Y D Kim Cosmology: small-scale issues Joel R Primack Big Bang nucleosynthesis and particle dark matter Karsten Jedamzik and Maxim Pospelov Particle models and the small-scale structure of dark matter Torsten Bringmann DARK MATTER AND COLLIDERS Dark matter in the MSSM R C Cotta, J S Gainer, J L Hewett and T G Rizzo The role of an e+e- linear collider in the study of cosmic dark matter M Battaglia Collider, direct and indirect detection of supersymmetric dark matter Howard Baer, Eun-Kyung Park and Xerxes Tata INDIRECT PARTICLE DARK MATTER SEARCHES:EXPERIMENTS PAMELA and indirect dark matter searches M Boezio et al An indirect search for dark matter using antideuterons: the GAPS experiment C J Hailey Perspectives for indirect dark matter search with AMS-2 using cosmic-ray electrons and positrons B Beischer, P von Doetinchem, H Gast, T Kirn and S Schael Axion searches with helioscopes and astrophysical signatures for axion(-like) particles K Zioutas, M Tsagri, Y Semertzidis, T Papaevangelou, T Dafni and V Anastassopoulos The indirect search for dark matter with IceCube Francis Halzen and Dan Hooper DIRECT DARK MATTER SEARCHES:EXPERIMENTS Gaseous dark matter detectors G Sciolla and C J Martoff Search for dark matter with CRESST Rafael F Lang and Wolfgang Seidel DIRECT AND INDIRECT PARTICLE DARK MATTER SEARCHES:THEORY Dark matter annihilation around intermediate mass black holes: an update Gianfranco Bertone, Mattia Fornasa, Marco Taoso and Andrew R Zentner Update on the direct detection of dark matter in MSSM models with non-universal Higgs masses John Ellis, Keith A Olive and Pearl Sandick Dark stars: a new study of the first stars in the Universe Katherine Freese, Peter Bodenheimer, Paolo Gondolo and Douglas Spolyar Determining the mass of dark matter particles with direct detection experiments Chung-Lin Shan The detection of subsolar mass dark matter halos Savvas M Koushiappas Neutrino coherent scattering rates at direct dark matter detectors Louis E Strigari Gamma rays from dark matter annihilation in the central region of the Galaxy Pasquale Dario Serpico and Dan Hooper DARK MATTER MODELS The dark matter interpretation of the 511 keV line Céline Boehm Axions as dark matter particles Leanne D Duffy and Karl van Bibber Sterile neutrinos Alexander Kusenko Dark matter candidates Lars Bergström Minimal dark matter: model and results Marco Cirelli and Alessandro Strumia Shedding light on the dark sector with direct WIMP production Partha Konar, Kyoungchul Kong, Konstantin T Matchev and Maxim Perelstein Axinos as dark matter particles Laura Covi and Jihn E Kim
NASA Technical Reports Server (NTRS)
Aramaki, T.; Boggs, S.; Bufalino, S.; Dal, L.; von Doetinchem, P.; Donato, F.; Fornengo, N.; Fuke, H.; Grefe, M.; Hailey, C.;
2016-01-01
Recent years have seen increased theoretical and experimental effort towards the first-ever detection of cosmic-ray antideuterons, in particular as an indirect signature of dark matter annihilation or decay. In contrast to indirect dark matter searches using positrons, antiprotons, or gamma-rays, which suffer from relatively high and uncertain astrophysical backgrounds, searches with antideuterons benefit from very suppressed conventional backgrounds, offering a potential breakthrough in unexplored phase space for dark matter. This article is based on the first dedicated cosmic-ray antideuteron workshop, which was held at UCLA in June 2014. It reviews broad classes of dark matter candidates that result in detectable cosmic-ray antideuteron fluxes, as well as the status and prospects of current experimental searches. The coalescence model of antideuteron production and the influence of antideuteron measurements at particle colliders are discussed. This is followed by a review of the modeling of antideuteron propagation through the magnetic fields, plasma currents, and molecular material of our Galaxy, the solar system, the Earth's geomagnetic field, and the atmosphere. Finally, the three ongoing or planned experiments that are sensitive to cosmic-ray antideuterons, BESS, AMS-02, and GAPS, are detailed. As cosmic-ray antideuteron detection is a rare event search, multiple experiments with orthogonal techniques and backgrounds are essential. Therefore, the combination of AMS-02 and GAPS antideuteron searches is highly desirable. Many theoretical and experimental groups have contributed to these studies over the last decade, this review aims to provide the first coherent discussion of the relevant dark matter theories that antideuterons probe, the challenges to predictions and interpretations of antideuteron signals, and the experimental efforts toward cosmic antideuteron detection.
Damage Assessment of Creep Tested and Thermally Aged Metallic Alloys Using Acousto-Ultrasonics
NASA Technical Reports Server (NTRS)
Gyekenyesi, Andrew L.; Kautz, Harold E.; Baaklini, George Y.
2001-01-01
In recent years emphasis has been placed on the early detection of material changes experienced in turbine powerplant components. During the scheduled overhaul of a turbine, the current techniques of examination of various hot section components aim to find flaws such as cracks, wear, and erosion, as well as excessive deformations. Thus far, these localized damage modes have been detected with satisfactory results. However, the techniques used to find these flaws provide no information on life until the flaws are actually detected. Major improvements in damage assessment, safety, as well as more accurate life prediction could be achieved if nondestructive evaluation (NDE) techniques could be utilized to sense material changes that occur prior to the localized defects mentioned. Because of elevated temperatures and excessive stresses, turbine components may experience creep behavior. As a result, it is desirable to monitor and access the current condition of such components. Research at the NASA Glenn Research Center involves developing and utilizing an NDE technique that discloses distributed material changes that occur prior to the localized damage detected by the current methods of inspection. In a recent study, creep processes in a nickel-base alloy were the life-limiting condition of interest, and the NDE technique was acousto-ultrasonics (AU). AU is an NDE technique that utilizes two ultrasonic transducers to interrogate the condition of a test specimen. The sending transducer introduces an ultrasonic pulse at a point on the surface of the specimen while a receiving transducer detects the signal after it has passed through the material. The goal of the method is to correlate certain parameters of the detected waveform to characteristics of the material between the two transducers. Here, the waveform parameter of interest is the attenuation due to internal damping for which information is being garnered from the frequency domain. The parameters utilized to indirectly quantify the attenuation are the ultrasonic decay rate as well as various moments of the frequency power spectrum. A new, user-friendly, graphical interface AU system was developed at NASA Glenn. This system is an all-inclusive, multifunction system that controls the sending and receiving ultrasonic transducers as well as all posttest signal analysis. The system's postprocessing software calculates the multiple parameters used to study the material of interest.
NASA Astrophysics Data System (ADS)
Brennan, A.; Onel, L. C.; Gianella, M.; Ronnie, G.; Aguila, A. L.; Hancock, G.; Whalley, L.; Seakins, P. W.; Ritchie, G.; Heard, D. E.
2017-12-01
HO2 is an important species in the atmosphere, as it is involved in the HOx radical reaction cycle that is critical to the oxidation of atmospheric pollutants and the ultimate cleaning of the troposphere. One of the most widely utilised methods to measure HO2 is Fluorescence Assay by Gas Expansion (FAGE), which indirectly measures HO2 by sampling into a low pressure cell and titrating HO2 with NO to produce OH that is then detected by Laser Induced Fluorescence. This is an indirect and non-absolute detection technique that requires careful calibration to convert the measured signal into [HO2], which involves the photolysis of H2O at 185 nm to produce OH and HO2, and is subject to 30 % errors at 2σ level. The work presented here shows the validation of the FAGE technique and its calibration procedure through inter-comparison experiments between the non-absolute FAGE technique and Cavity Ringdown Spectroscopy (CRDS), an absolute absorption based method. The CRDS system was used to excite the first O-H overtone of the HO2 absorption band at 1506.43 nm, and features a cavity length of 1.2 m and a total path of 60 km. The experiments were performed inside the 2.25 m3 stainless steel Highly Instrumented Reactor for Atmospheric Chemistry (HIRAC), using a synthetic air mixture at 150 and 1000 mbar of pressure and 298 K. HO2 was generated by photolysis of Cl2 at 365 nm in the presence of CH3OH and O2, and the [HO2] was monitored using both instruments. Additionally, monitoring the temporal decay of HO2 during its self-reaction provided an alternative calibration method for the FAGE instrument, and allowed the absorption cross section of HO2 at 1506.43 nm, σHO2, to be measured. FAGE calibration factors determined through the second order decays of HO2 at 1000 mbar agreed within 8 % of the H2O photolysis method, and determinations of σHO2 at 150 and 1000 mbar agree with previously reported data within 20 % and 12 % respectively. [HO2] correlation plots between the two instruments at 150 and 1000 mbar showed very good agreements of 0.863 ± 0.004 and 0.903 ± 0.002 respectively. This consistency between the indirect FAGE and direct CRDS measurements of HO2 validates the FAGE method, which is widely used for field measurements of HO2 in the troposphere.
Forecasting of indirect consumables for a Job Shop
NASA Astrophysics Data System (ADS)
Shakeel, M.; Khan, S.; Khan, W. A.
2016-08-01
A job shop has an arrangement where similar machines (Direct consumables) are grouped together and use indirect consumables to produce a product. The indirect consumables include hack saw blades, emery paper, painting brush etc. The job shop is serving various orders at a particular time for the optimal operation of job shop. Forecasting is required to predict the demand of direct and indirect consumables in a job shop. Forecasting is also needed to manage lead time, optimize inventory cost and stock outs. The objective of this research is to obtain the forecast for indirect consumables. The paper shows how job shop can manage their indirect consumables more accurately by establishing a new technique of forecasting. This results in profitable use of job shop by multiple users.
[Laboratory unification: advantages and disadvantages for clinical microbiology].
Andreu, Antonia; Matas, Lurdes
2010-10-01
This article aims to reflect on which areas or tasks of microbiology laboratories could be unified with those of clinical biochemistry, hematology, immunology or pathology laboratories to benefit patients and the health system, as well as the areas that should remain independent since their amalgamation would not only fail to provide a benefit but could even jeopardize the quality of microbiological diagnosis, and consequently patient care. To do this, the distinct analytic phases of diagnosis are analyzed, and the advantages and disadvantages of amalgamation are evaluated in each phase. The pros and cons of the unification of certain areas such as the computer system, occupational risk units, customer service, purchasing logistics, and materials storage, etc, are also discussed. Lastly, the effect of unification on urgent microbiology diagnosis is analyzed. Microbiological diagnosis should be unique. The microbiologist should perform an overall evaluation of the distinct techniques used for a particular patient, both those that involve direct diagnosis (staining, culture, antigen detection techniques or molecular techniques) and indirect diagnosis (antibody detection). Moreover, the microbiology laboratory should be independent, with highly trained technicians and specialists in microbiology that provide added value as experts in infection and as key figures in the process of establishing a correct etiological diagnosis. Copyright © 2010 Elsevier España S.L. All rights reserved.
Preparation of genosensor for detection of specific DNA sequence of the hepatitis B virus
NASA Astrophysics Data System (ADS)
Honorato Castro, Ana C.; França, Erick G.; de Paula, Lucas F.; Soares, Marcia M. C. N.; Goulart, Luiz R.; Madurro, João M.; Brito-Madurro, Ana G.
2014-09-01
An electrochemical genosensor was constructed for detection of specific DNA sequence of the hepatitis B virus, based on graphite electrodes modified with poly(4-aminophenol) and incorporating a specific oligonucleotide probe. The modified electrode containing the probe was evaluated by differential pulse voltammetry, before and after incubation with the complementary oligonucleotide target. Detection was performed by monitoring oxidizable DNA bases (direct detection) or using ethidium bromide as indicator of the hybridization process (indirect detection). The device showed a detection limit for the oligonucleotide target of 2.61 nmol L-1. Indirect detection using ethidium bromide was promising in discriminating mismatches, which is a very desirable attribute for detection of disease-related point mutations. In addition, it was possible to observe differences between hybridized and non-hybridized surfaces by atomic force microscopy.
Suchorab, Zbigniew; Barnat-Hunek, Danuta; Franus, Małgorzata; Łagód, Grzegorz
2016-04-27
This article is focused on lightweight aggregate-concrete modified by municipal sewage sludge and lightweight aggregate-concrete obtained from light aggregates. The article presents laboratory examinations of material physical parameters. Water absorptivity of the examined material was decreased by the admixture of water emulsion of reactive polysiloxanes. Water transport properties were determined using Time Domain Reflectometry, an indirect technique for moisture detection in porous media. Together with basic physical parameters, the heat conductivity coefficient λ was determined for both types of lightweight aggregate-concrete. Analysis of moisture and heat properties of the examined materials confirmed the usefulness of light aggregates supplemented with sewage sludge for prospective production.
NASA Astrophysics Data System (ADS)
Duarte, Janaina; Pacheco, Marcos T. T.; Silveira, Landulfo, Jr.; Machado, Rosangela Z.; Martins, Rodrigo A. L.; Zangaro, Renato A.; Villaverde, Antonio G. J. B.
2001-05-01
Near-infrared (NIR) Raman spectroscopy has been studied for the last years for many biomedical applications. It is a powerful tool for biological materials analysis. Toxoplasmosis is an important zoonosis in public health, cats being the principal responsible for the transmission of the disease in Brazil. The objective of this work is to investigate a new method of diagnosis of this disease. NIR Raman spectroscopy was used to detect anti Toxoplasma gondii antibodies in blood sera from domestic cats, without sample preparation. In all, six blood serum samples were used for this study. A previous serological test was done by the Indirect Immunoenzymatic Assay (ELISA) to permit a comparative study between both techniques and it showed that three serum samples were positive and the other three were negative to toxoplasmosis. Raman spectra were taken for all the samples and analyzed by using the principal components analysis (PCA). A diagnosis parameter was defined from the analysis of the second and third principal components of the Raman spectra. It was found that this parameter can detect the infection level of the animal. The results have indicated that NIR Raman spectroscopy, associated to the PCA can be a promising technique for serological analysis, such as toxoplasmosis, allowing a fast and sensitive method of diagnosis.
Qiu, Jun; Wang, Jinhao; Xu, Zhongqi; Liu, Huiqing; Ren, Jie
2017-01-01
The branched-chain amino acids (BCAAs) including leucine (Leu), isoleucine (Ile) and valine (Val) play a pivotal role in the human body. Herein, we developed capillary electrophoresis (CE) coupled with conventional UV detector to quantify underivatized BCAAs in two kinds of sport nutritional supplements. For direct UV detection at 195 nm, the BCAAs (Leu, two enantiomers of Ile and Val) were separated in a background electrolyte (BGE) consisting of 40.0 mmol/L sodium tetraborate, and 40.0 mmol/L β-cyclodextrin (β-CD) at pH 10.2. In addition, the indirect UV detection at 264 nm was achieved in a BGE of 2.0 mmol/L Na2HPO4, 10.0 mmol/L p-aminosalicylic acid (PAS) as UV absorbing probe, and 40.0 mmol/L β-CD at pH 12.2. The β-CD significantly benefited the isomeric separation of Leu, L- and D-Ile. The optimal conditions allowed the LODs (limit of detections) of direct and indirect UV absorption detection to be tens μmol/L level, which was comparable to the reported CE inline derivatization method. The RSDs (relative standard deviations) of migration time and peak area were less than 0.91% and 3.66% (n = 6). Finally, CE with indirect UV detection method was applied for the quantitation of BCAAs in two commercial sport nutritional supplements, and good recovery and precision were obtained. Such simple CE method without tedious derivatization process is feasible of quality control and efficacy evaluation of the supplemental proteins.
Liu, Huiqing; Ren, Jie
2017-01-01
The branched-chain amino acids (BCAAs) including leucine (Leu), isoleucine (Ile) and valine (Val) play a pivotal role in the human body. Herein, we developed capillary electrophoresis (CE) coupled with conventional UV detector to quantify underivatized BCAAs in two kinds of sport nutritional supplements. For direct UV detection at 195 nm, the BCAAs (Leu, two enantiomers of Ile and Val) were separated in a background electrolyte (BGE) consisting of 40.0 mmol/L sodium tetraborate, and 40.0 mmol/L β-cyclodextrin (β-CD) at pH 10.2. In addition, the indirect UV detection at 264 nm was achieved in a BGE of 2.0 mmol/L Na2HPO4, 10.0 mmol/L p-aminosalicylic acid (PAS) as UV absorbing probe, and 40.0 mmol/L β-CD at pH 12.2. The β-CD significantly benefited the isomeric separation of Leu, L- and D-Ile. The optimal conditions allowed the LODs (limit of detections) of direct and indirect UV absorption detection to be tens μmol/L level, which was comparable to the reported CE inline derivatization method. The RSDs (relative standard deviations) of migration time and peak area were less than 0.91% and 3.66% (n = 6). Finally, CE with indirect UV detection method was applied for the quantitation of BCAAs in two commercial sport nutritional supplements, and good recovery and precision were obtained. Such simple CE method without tedious derivatization process is feasible of quality control and efficacy evaluation of the supplemental proteins. PMID:28640882
Parameter Estimation for a Hybrid Adaptive Flight Controller
NASA Technical Reports Server (NTRS)
Campbell, Stefan F.; Nguyen, Nhan T.; Kaneshige, John; Krishnakumar, Kalmanje
2009-01-01
This paper expands on the hybrid control architecture developed at the NASA Ames Research Center by addressing issues related to indirect adaptation using the recursive least squares (RLS) algorithm. Specifically, the hybrid control architecture is an adaptive flight controller that features both direct and indirect adaptation techniques. This paper will focus almost exclusively on the modifications necessary to achieve quality indirect adaptive control. Additionally this paper will present results that, using a full non -linear aircraft model, demonstrate the effectiveness of the hybrid control architecture given drastic changes in an aircraft s dynamics. Throughout the development of this topic, a thorough discussion of the RLS algorithm as a system identification technique will be provided along with results from seven well-known modifications to the popular RLS algorithm.
NMR Detection Using Laser-Polarized Xenon as a DipolarSensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Granwehr, Josef; Urban, Jeffry T.; Trabesinger, Andreas H.
2005-02-28
Hyperpolarized Xe-129 can be used as a sensor to indirectly detect NMR spectra of heteronuclei that are neither covalently bound nor necessarily in direct contact with the Xe atoms, but coupled through long-range intermolecular dipolar couplings. In order to reintroduce long-range dipolar couplings the sample symmetry has to be broken. This can be done either by an asymmetric sample arrangement, or by breaking the symmetry of the spin magnetization with field gradient pulses. Experiments are performed where only a small fraction of the available Xe-129 magnetization is used for each point, so that a single batch of xenon suffices formore » the point-by-point acquisition of a heteronuclear NMR spectrum. Examples with H-1 as analyte nucleus show that these methods have the potential to obtain spectra with a resolution that is high enough to determine homonuclear J couplings. The applicability of this technique with remote detection is discussed.« less
Molecular biology of Ganoderma pathogenicity and diagnosis in coconut seedlings.
Kandan, A; Radjacommare, R; Ramanathan, A; Raguchander, T; Balasubramanian, P; Samiyappan, R
2009-01-01
The pathogenicity of Ganoderma boninense was tested on coconut seedlings under greenhouse conditions and infection confirmed by using immunological and molecular diagnostic tools. Desiccation of older leaves and the emergence of sporophores were observed from pathogen-inoculated seedlings, whereas a control seedling does not show any pathogenic symptoms. Mature sporophores were formed within 10-13 weeks after inoculation. Polyclonal antibodies raised against mycelial proteins of Ganoderma were used for detection of Ganoderma in infected field palm and seedlings through indirect enzyme-linked immunosorbent assay technique. We adopted dot-immunobinding assay for the detection of Ganoderma from greenhouse and field samples. Under nucleic-acid-based diagnosis, G. boninense (167 bp) was detected from artificially inoculated seedlings and infected field palms by polymerase chain reaction. Apart from these, histopathological studies also support the Ganoderma pathogenicity in coconut seedlings. The pathogenicity test and combination of all the three diagnostic methods for Ganoderma could be highly reliable, rapid, sensitive and effective screening of resistance in planting material in the future.
An x ray scatter approach for non-destructive chemical analysis of low atomic numbered elements
NASA Technical Reports Server (NTRS)
Ross, H. Richard
1993-01-01
A non-destructive x-ray scatter (XRS) approach has been developed, along with a rapid atomic scatter algorithm for the detection and analysis of low atomic-numbered elements in solids, powders, and liquids. The present method of energy dispersive x-ray fluorescence spectroscopy (EDXRF) makes the analysis of light elements (i.e., less than sodium; less than 11) extremely difficult. Detection and measurement become progressively worse as atomic numbers become smaller, due to a competing process called 'Auger Emission', which reduces fluorescent intensity, coupled with the high mass absorption coefficients exhibited by low energy x-rays, the detection and determination of low atomic-numbered elements by x-ray spectrometry is limited. However, an indirect approach based on the intensity ratio of Compton and Rayleigh scattered has been used to define light element components in alloys, plastics and other materials. This XRS technique provides qualitative and quantitative information about the overall constituents of a variety of samples.
Lallier, R.; Olivier, G.; Chartier, P.; Turcotte, C.; Dionet, B.; Paulhus, P.
1981-01-01
Presence of the bacterial kidney disease in salmonid fish in Quebec During the summers of 1979 and 1980, wild and hatchery fish were analysed for the presence of the bacterial kidney disease (BKD) agent in salmonid fish in Quebec by the indirect immunofluorescence technique. The causative agent of BKD was detected in all hatcheries tested. Ten to 25% of the fish were positive. The presence of this agent was independent of age and species. We were unable to detect the BKD in fish from the rivers in the northern part of Quebec (over the 50th parallel). The first detection of BKD in Quebec was made in the spring of 1979 in a hatchery. A high mortality occurred in fish over a year old. The majority of the fish were positive by immunofluorescence and the bacteriun was isolated from some fish. Three weeks before the disease appeared, six ponds received fish from this hatchery. No mortality was observed in those ponds and in the middle of the summer the percentage of carrier fish by immunofluorescence was approximately 20%. PMID:7340922
André, Marcos Rogério; Adania, Cristina Harumi; Teixeira, Rodrigo Hidalgo Friciello; Allegretti, Silmara Marques; Machado, Rosangela Zacarias
2011-03-01
Large and small piroplasms have been observed in the blood smears of various wild carnivores, but few studies utilizing molecular characterization have been done. The goal of this present study was to investigate the presence of Babesia sp. by molecular and serologic techniques in exotic and neotropical carnivores maintained in captivity at Brazilian zoos. Blood and sera samples were collected from 146 Brazilian wild felids, 21 exotic felids, 1 genet (Genetta tigrina), 3 European wolves (Canis lupus), and 94 Brazilian wild canids in Brazilian zoos in the São Paulo and Mato Grosso states and in the Federal District. A total of 53 wild felids (31.74%) and 10 wild canids (10.31%) were seropositive for Babesia canis by Indirect Fluorescent Antibody Test (IFAT). Antibodies were detected in ocelots, little-spotted cats, margays, pampas cats, jaguars, pumas, jaguarundis, crab-eating foxes, and bush dogs. Babesia sp. DNA, with high similarity to B. leo, was detected in one pampas cat and one genet.
[Detection of serum anti-salivary duct antibody and its clinical significance].
Zhang, H; Shi, G Y; Cai, X H
1990-11-01
The authors developed an indirect immunofluorescence technique for the detection of Anti-salivary duct antibody (ASDA) and screened 34 patients with rheumatoid arthritis, 15 patients with Sjögren's syndrome-rheumatoid arthritis and 15 patients with primary Sjögren's syndrome, 63 cases with other connective tissue diseases, 9 cases with other diseases and 40 normal controls. The incidence of ASDA in patients with Sjögren's syndrome rheumatoid arthritis (66.67%) or rheumatoid arthritis (32.35%) was significantly higher than that in normal controls (P less than 0.001). In patients with primary Sjögren's syndrome and other CTDs, non-CTDs, no ASDA was found. However, in patients with Sjögren's syndrome-rheumatoid arthritis or rheumatoid arthritis alone, ASDA was not correlated with age, sex, disease duration or serological findings. The result suggests that the detection of serum ASDA might be useful in the differentiation of Sjögren's syndrome with rheumatoid arthritis from primary Sjögren's syndrome with arthralgia and/or arthritis.
REVIEWS OF TOPICAL PROBLEMS: Relic gravitational waves and cosmology
NASA Astrophysics Data System (ADS)
Grishchuk, Leonid P.
2005-12-01
The paper begins with a brief recollection of interactions of the author with Ya B Zeldovich in the context of the study of relic gravitational waves. The principles and early results on the quantum-mechanical generation of cosmological perturbations are then summarized. The expected amplitudes of relic gravitational waves differ in various frequency windows, and therefore the techniques and prospects of their detection are distinct. One section of the paper describes the present state of efforts in direct detection of relic gravitational waves. Another section is devoted to indirect detection via the anisotropy and polarization measurements of the cosmic microwave background (CMB) radiation. It is emphasized throughout the paper that the inference about the existence and expected amount of relic gravitational waves is based on a solid theoretical foundation and the best available cosmological observations. It is also explained in great detail what went wrong with the so-called 'inflationary gravitational waves', whose amount is predicted by inflationary theorists to be negligibly small, thus depriving them of any observational significance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kobayshi, Takeshi; Nishiyama, Yusuke; Pruski, Marek
The main focus of this chapter is to address experimental strategies on the subject by providing a hands-on guide to fast MAS experiments, with a particular focus on indirect detection. Although our experience is limited to our respective laboratories in Ames and Yokohama, we hope that our descriptions of experimental setups and optimization procedures are sufficiently general to be applicable to all modern instruments. The chapter is organized as follows. Section 2 below introduces briefly the fast MAS technology and its main advantages. In Section 3, we describe the hardware associated with this remarkable technology and provide practical advices onmore » its use, including procedures for loading and unloading the samples, maintaining the probe, reducing t 1 noise, etc. In Section 4, we describe the principles and hands-on aspects of experiments involving the indirect detection of spin-1/2 and 14N nuclei« less
Indirect measures as a signal for evaluative change.
Perugini, Marco; Richetin, Juliette; Zogmaister, Cristina
2014-01-01
Implicit and explicit attitudes can be changed by using evaluative learning procedures. In this contribution we investigated an asymmetric effect of order of administration of indirect and direct measures on the detection of evaluative change: A change in explicit attitudes is more likely detected if they are measured after implicit attitudes, whereas these latter change regardless of the order. This effect was demonstrated in two studies (n=270; n=138) using the self-referencing task whereas it was not found in a third study (n=151) that used a supraliminal sequential evaluative conditioning paradigm. In all studies evaluative change was present only for contingency aware participants. We discuss a potential explanation underlying the order of measure effect entailing that, in some circumstances, an indirect measure is not only a measure but also a signal that can be detected through self-perception processes and further elaborated at the propositional level.
Diagnostic performance of indirect MR arthrography for the diagnosis of rotator cuff tears at 3.0 T.
Lee, Ji Hyun; Yoon, Young Cheol; Jee, Sukkyung
2015-06-01
Indirect magnetic resonance (MR) arthrography is a non-invasive method for shoulder imaging. However, there are no studies that have examined the diagnostic performance of indirect MR arthrography for the diagnosis of rotator cuff tears in a large patient population. To assess the diagnostic performance of indirect fast spin-echo (FSE) MR arthrography for the diagnosis of rotator cuff tears at 3.0 T. A total of 149 patients who had undergone indirect shoulder MR arthrography followed by arthroscopic surgery were enrolled in this retrospective study. Two musculoskeletal radiologists evaluated images from each patient for the presence of supraspinatus-infraspinatus (SSP-ISP) or subscapularis (SSC) tendon tears. Using the arthroscopic findings as the reference standard, the overall diagnostic performance and detection rates for SSP-ISP and SSC tendon tears were calculated. The sensitivity, specificity, and accuracy of readers I and II for the diagnosis of SSP-ISP tendon tears were 94% and 95%, 89% and 85%, and 93% and 93%, respectively. The sensitivity of imaging for detection of SSP-ISP tendon tears by readers I and II were 100% and 100% for full-thickness tears and 84% and 86% for partial-thickness tears, respectively. The sensitivity, specificity, and accuracy of readers I and II for the diagnosis of SSC tendon tears were 80% and 76%, 89% and 93%, and 85% and 85%, respectively. Indirect MR arthrography is useful for the detection of SSP-ISP and SSC tendon tears. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
NASA Astrophysics Data System (ADS)
Zhang, Bin; Qian, Yao; Wu, Yuntian; Yang, Y. B.
2018-04-01
To further the technique of indirect measurement, the contact-point response of a moving test vehicle is adopted for the damage detection of bridges. First, the contact-point response of the vehicle moving over the bridge is derived both analytically and in central difference form (for field use). Then, the instantaneous amplitude squared (IAS) of the driving component of the contact-point response is calculated by the Hilbert transform, making use of its narrow-band feature. The IAS peaks serve as the key parameter for damage detection. In the numerical simulation, a damage (crack) is modeled by a hinge-spring unit. The feasibility of the proposed method to detect the location and severity of a damage or multi damages of the bridge is verified. Also, the effects of surface roughness, vehicle speed, measurement noise and random traffic are studied. In the presence of ongoing traffic, the damages of the bridge are identified from the repeated or invariant IAS peaks generated for different traffic flows by the same test vehicle over the bridge.
The waning of the WIMP? A review of models, searches, and constraints
NASA Astrophysics Data System (ADS)
Arcadi, Giorgio; Dutra, Maíra; Ghosh, Pradipta; Lindner, Manfred; Mambrini, Yann; Pierre, Mathias; Profumo, Stefano; Queiroz, Farinaldo S.
2018-03-01
Weakly Interacting Massive Particles (WIMPs) are among the best-motivated dark matter candidates. No conclusive signal, despite an extensive search program that combines, often in a complementary way, direct, indirect, and collider probes, has been detected so far. This situation might change in near future due to the advent of one/multi-TON Direct Detection experiments. We thus, find it timely to provide a review of the WIMP paradigm with focus on a few models which can be probed at best by these facilities. Collider and Indirect Detection, nevertheless, will not be neglected when they represent a complementary probe.
Concept and clinical application of the resin-coating technique for indirect restorations.
Nikaido, Toru; Tagami, Junji; Yatani, Hirofumi; Ohkubo, Chikahiro; Nihei, Tomotaro; Koizumi, Hiroyasu; Maseki, Toshio; Nishiyama, Yuichiro; Takigawa, Tomoyoshi; Tsubota, Yuji
2018-03-30
The resin-coating technique is one of the successful bonding techniques used for the indirect restorations. The dentin surfaces exposed after cavity preparation are coated with a thin film of a coating material or a dentin bonding system combined with a flowable composite resin. Resin coating can minimize pulp irritation and improve the bond strength between a resin cement and tooth structures. The technique can also be applied to endodontically treated teeth, resulting in prevention of coronal leakage of the restorations. Application of a resin coating to root surface provides the additional benefit of preventing root caries in elderly patients. Therefore, the coating materials have the potential to reinforce sound tooth ("Super Tooth" formation), leading to preservation of maximum tooth structures.
Shi, Hong-Fei; Xiong, Jin; Chen, Yi-Xin; Wang, Jun-Fei; Qiu, Xu-Sheng; Huang, Jie; Gui, Xue-Yang; Wen, Si-Yuan; Wang, Yin-He
2017-03-14
The optimal method for the reduction and fixation of posterior malleolar fracture (PMF) remains inconclusive. Currently, both of the indirect and direct reduction techniques are widely used. We aimed to compare the reduction quality and clinical outcome of posterior malleolar fracture managed with the direct reduction technique through posterolateral approach or the indirect reduction technique using ligamentotaxis. Patients with a PMF involving over 25% of the articular surface were recruited and assigned to the direct reduction (DR) group or the indirect reduction (IR) group. Following reduction and fixation of the fracture, the quality of fracture reduction was evaluated in post-operative CT images. Clinical and radiological follow-ups were performed at 6 weeks, 3 months, 6 months, 12 months, and then at 6 month-intervals postoperatively. Functional outcome (AOFAS score), ankle range of motion, and Visual Analog Scale (VAS) were evaluated at the last follow-up. Statistical differences were compared between the DR and IR groups considering the patient demographics, quality of fracture reduction, AOFAS score, and VAS. Totally 116 patients were included, wherein 64 cases were assigned to the DR group and 52 cases were assigned to the IR group. The quality of fracture reduction was significant higher in the DR group (P = 0.038). In the patients who completed a minimum of 12 months' follow-up, a median AOFAS score of 87 was recorded in the DR group, which was significantly higher than that recorded in the IR group (a median score of 80). The ankle range of motion was slightly better in the DR group, with the mean dorsiflexion restriction recorded to be 5.2° and 6.1° in the DR and IR group respectively (P = 0.331). Similar VAS score was observed in the two groups (P = 0.419). The direct reduction technique through a posterolateral approach provide better quality of fracture reduction and functional outcome in the management of PMF over 25% of articular surface, as compared with the indirect reduction technique using ligamentotaxis. NCT02801474 (retrospectively registered, June 2016, ClinicalTrails.gov).
Application of Laser Induced Breakdown Spectroscopy under Polar Conditions
NASA Astrophysics Data System (ADS)
Clausen, J. L.; Hark, R.; Bol'shakov, A.; Plumer, J.
2015-12-01
Over the past decade our research team has evaluated the use of commercial-off-the-shelf laser-induced breakdown spectroscopy (LIBS) for chemical analysis of snow and ice samples under polar conditions. One avenue of research explored LIBS suitability as a detector of paleo-climate proxy indicators (Ca, K, Mg, and Na) in ice as it relates to atmospheric circulation. LIBS results revealed detection of peaks for C and N, consistent with the presence of organic material, as well as major ions (Ca, K, Mg, and Na) and trace metals (Al, Cu, Fe, Mn, Ti). The detection of Ca, K, Mg, and Na confirmed that LIBS has sufficient sensitivity to be used as a tool for characterization of paleo-climate proxy indicators in ice-core samples. Techniques were developed for direct analysis of ice as well as indirect measurements of ice via melting and filtering. Pitfalls and issues of direct ice analysis using several cooling techniques to maintain ice integrity will be discussed. In addition, a new technique, laser ablation molecular isotopic spectroscopy (LAMIS) was applied to detection of hydrogen and oxygen isotopes in ice as isotopic analysis of ice is the main tool in paleoclimatology and glaciology studies. Our results demonstrated that spectra of hydroxyl isotopologues 16OH, 18OH, and 16OD can be recorded with a compact spectrograph to determine hydrogen and oxygen isotopes simultaneously. Quantitative isotopic calibration for ice analysis can be accomplished using multivariate chemometric regression as previously realized for water vapor. Analysis with LIBS and LAMIS required no special sample preparation and was about ten times faster than analysis using ICP-MS. Combination of the two techniques in one portable instrument for in-field analysis appears possible and would eliminate the logistical and cost issues associated with ice core management.
Trace elemental analysis of human breast cancerous blood by advanced PC-WDXRF technique
NASA Astrophysics Data System (ADS)
Singh, Ranjit; Kainth, Harpreet Singh; Prasher, Puneet; Singh, Tejbir
2018-03-01
The objective of this work is to quantify the trace elements of healthy and non-healthy blood samples by using advanced polychromatic source based wavelength dispersive X-ray fluorescence (PC-WDXRF) technique. The imbalances in trace elements present in the human blood directly or indirectly lead to the carcinogenic process. The trace elements 11Na, 12Mg, 15P, 16S, 17Cl, 19K, 20Ca, 26Fe, 29Cu and 30Zn are identified and their concentrations are estimated. The experimental results clearly discuss the variation and role of various trace elements present in the non-healthy blood samples relative to the healthy blood samples. These results establish future guidelines to probe the possible roles of essential trace elements in the breast carcinogenic processes. The instrumental sensitivity and detection limits for measuring the elements in the atomic range 11 ≤ Z ≤ 30 have also been discussed in the present work.
Addison's Disease Revisited in Poland: Year 2008 versus Year 1990
Kasperlik-Zaluska, Anna A.; Czarnocka, Barbara; Jeske, Wojciech; Papierska, Lucyna
2010-01-01
This study aimed at comparing two groups of patients with Addison's disease: A, including 180 patients described in 1991 and B, consisting of 138 patients registered since 1991. The incidence of coexisting autoimmune disorders was evaluated and etiological factors were analyzed. Immunological and imaging studies (computed tomography in group B) were performed. Adrenal autoantibodies were examined by an indirect immunofluorescence technique in group A, and by the assay measuring autoantibodies against steroid 21-hydroxylase in group B. Adrenal autoantibodies were revealed in 37% of patients examined by the immunofluorescence method and in 63% investigated by the modern technique. Tuberculosis was found in 52 patients in the group A and in two patients in the group B; metastatic infiltrations of the adrenals in CT were detected in 16 patients. Probable autoimmune Addison's disease was diagnosed in 125/180 patients (69%) in the group A and in 116/138 patients (84%) in the group B. PMID:21188237
[Value of positive auto controls in the gel centrifugation method].
Eichler, H; Kretschmer, V
1994-01-01
We studied 97 samples of patients being positive in the autocontrol of the indirect antiglobulin test (IAT) in the gel system (DiaMed). In 83.2%, retesting with monospecific anti-IgG serum gave also positive results, due to a specific phenomenon caused, for example, by drug-specific antibodies (AB), warm auto-AB or allo-AB. In contrast, only 52.9% of the samples retested by the standard tube technique with polyspecific antiglobulin serum reacted positive. Only in 6 patients slightly increased cold agglutinins could be detected. None of the investigated patients showed any clinical or laboratory signs of hemolysis except one with pernicious anemia. We conclude that positive results of the autocontrol in the gel IAT should be confirmed by an additional DAT in the tube technique. If this second test shows a negative result, transfusions can take place without any restrictions.
Serological and molecular detection of Theileria equi in sport horses of northeastern Brazil.
Ferreira, Edlainne P; Vidotto, Odilon; Almeida, Jonatas C; Ribeiro, Luana P S; Borges, Marcos V; Pequeno, Walter H C; Stipp, Danilo T; de Oliveira, Celso J B; Biondo, Alexander W; Vieira, Thállitha S W J; Vieira, Rafael F C
2016-08-01
Theileriosis is a worldwide protozoal tick-borne disease caused by Theileria equi, which may produce a variety of clinical signs and turn infected horses into lifetime carriers. This study has aimed to perform a serological and molecular detection of T. equi and associated factors in sports horses from six areas of northeastern Brazil. In overall, 59.6% horses were positive by indirect immunofluorescence assay and 50.4% by polymerase chain reaction. No significant association was found when presence of ticks, age, gender, anemia or total plasma proteins was analyzed with seropositivity and molecular techniques. Although a significant association of infection was found in two cities. Thus, local risk factors other than presence of ticks, horse age, gender, anemia and total plasmatic proteins may dictate prevalence of T. equi infection in sports horses, even in highly endemic areas with no control of infection prior to horse competitions. Copyright © 2016 Elsevier Ltd. All rights reserved.
Jorge, Sérgio; Monte, Leonardo G; Coimbra, Marco Antonio; Albano, Ana Paula; Hartwig, Daiane D; Lucas, Caroline; Seixas, Fabiana K; Dellagostin, Odir A; Hartleben, Cláudia P
2012-10-01
Leptospirosis is a globally prevalent zoonosis caused by pathogenic Leptospira spp.; several serologic variants have reservoirs in synanthropic rodents. The capybara is the largest living rodent in the world, and it has a wide geographical distribution in Central and South America. This rodent is a significant source of Leptospira since the agent is shed via urine into the environment and is a potential public health threat. In this study, we isolated and identified by molecular techniques a pathogenic Leptospira from capybara in southern Brazil. The isolated strain was characterized by partial rpoB gene sequencing and variable-number tandem-repeats analysis as L. interrogans, serogroup Icterohaemorrhagiae. In addition, to confirm the expression of virulence factors, the bacterial immunoglobulin-like proteins A and B expression was detected by indirect immunofluorescence using leptospiral specific monoclonal antibodies. This report identifies capybaras as an important source of infection and provides insight into the epidemiology of leptospirosis.
Rai, Rathika; Kumar, S Arun; Prabhu, R; Govindan, Ranjani Thillai; Tanveer, Faiz Mohamed
2017-01-01
Accuracy in fit of cast metal restoration has always remained as one of the primary factors in determining the success of the restoration. A well-fitting restoration needs to be accurate both along its margin and with regard to its internal surface. The aim of the study is to evaluate the marginal fit of metal ceramic crowns obtained by conventional inlay casting wax pattern using conventional impression with the metal ceramic crowns obtained by computer-aided design and computer-aided manufacturing (CAD/CAM) technique using direct and indirect optical scanning. This in vitro study on preformed custom-made stainless steel models with former assembly that resembles prepared tooth surfaces of standardized dimensions comprised three groups: the first group included ten samples of metal ceramic crowns fabricated with conventional technique, the second group included CAD/CAM-milled direct metal laser sintering (DMLS) crowns using indirect scanning, and the third group included DMLS crowns fabricated by direct scanning of the stainless steel model. The vertical marginal gap and the internal gap were evaluated with the stereomicroscope (Zoomstar 4); post hoc Turkey's test was used for statistical analysis. One-way analysis of variance method was used to compare the mean values. Metal ceramic crowns obtained from direct optical scanning showed the least marginal and internal gap when compared to the castings obtained from inlay casting wax and indirect optical scanning. Indirect and direct optical scanning had yielded results within clinically acceptable range.
Indirect addressing and load balancing for faster solution to Mandelbrot Set on SIMD architectures
NASA Technical Reports Server (NTRS)
Tomboulian, Sherryl
1989-01-01
SIMD computers with local indirect addressing allow programs to have queues and buffers, making certain kinds of problems much more efficient. Examined here are a class of problems characterized by computations on data points where the computation is identical, but the convergence rate is data dependent. Normally, in this situation, the algorithm time is governed by the maximum number of iterations required by each point. Using indirect addressing allows a processor to proceed to the next data point when it is done, reducing the overall number of iterations required to approach the mean convergence rate when a sufficiently large problem set is solved. Load balancing techniques can be applied for additional performance improvement. Simulations of this technique applied to solving Mandelbrot Sets indicate significant performance gains.
Chang, G J; Trent, D W; Vorndam, A V; Vergne, E; Kinney, R M; Mitchell, C J
1994-01-01
We previously described a reverse transcriptase-PCR using flavivirus genus-conserved and virus species-specific amplimers (D. W. Trent and G. J. Chang, p. 355-371, in Y. Becker and C. Darai; ed., Frontiers of Virology, vol. 1, 1992). Target amplification was improved by redesigning the amplimers, and a sensitive enzyme-linked immunosorbent assay (ELISA) technique has been developed to detect amplified digoxigenin (DIG)-modified DNA. A single biotin motif and multiple DIG motifs were incorporated into each amplicon, which permitted amplicon capture by a biotin-streptavidin interaction and detection with DIG-specific antiserum in a colorimetric ELISA. We evaluated the utility of this assay for detecting St. Louis encephalitis (SLE) viral RNA in infected mosquitoes and dengue viral RNA in human serum specimens. The reverse transcriptase-PCR-ELISA was as sensitive as isolation of SLE virus by cell culture in detecting SLE viral RNA in infected mosquitoes. The test was 89% specific and 95 to 100% sensitive for identification of dengue viral RNA in serum specimens compared with isolation of virus by Aedes albopictus C6/36 cell culture and identification by the indirect immunofluorescence assay. PMID:7512096
Choi, Seeyoung; Love, Paul E
2018-01-05
Oxidative inactivation of cysteine-dependent Protein Tyrosine Phosphatases (PTPs) by cellular reactive oxygen species (ROS) plays a critical role in regulating signal transduction in multiple cell types. The phosphatase activity of most PTPs depends upon a 'signature' cysteine residue within the catalytic domain that is maintained in the de-protonated state at physiological pH rendering it susceptible to ROS-mediated oxidation. Direct and indirect techniques for detection of PTP oxidation have been developed (Karisch and Neel, 2013). To detect catalytically active PTPs, cell lysates are treated with iodoacetyl-polyethylene glycol-biotin (IAP-biotin), which irreversibly binds to reduced (S - ) cysteine thiols. Irreversible oxidation of SHP-1 after treatment of cells with pervanadate or H 2 O 2 is detected with antibodies specific for the sulfonic acid (SO 3 H) form of the conserved active site cysteine of PTPs. In this protocol, we describe a method for the detection of the reduced (S - ; active) or irreversibly oxidized (SO 3 H; inactive) form of the hematopoietic PTP SHP-1 in thymocytes, although this method is applicable to any cysteine-dependent PTP in any cell type.
Chang, G J; Trent, D W; Vorndam, A V; Vergne, E; Kinney, R M; Mitchell, C J
1994-02-01
We previously described a reverse transcriptase-PCR using flavivirus genus-conserved and virus species-specific amplimers (D. W. Trent and G. J. Chang, p. 355-371, in Y. Becker and C. Darai; ed., Frontiers of Virology, vol. 1, 1992). Target amplification was improved by redesigning the amplimers, and a sensitive enzyme-linked immunosorbent assay (ELISA) technique has been developed to detect amplified digoxigenin (DIG)-modified DNA. A single biotin motif and multiple DIG motifs were incorporated into each amplicon, which permitted amplicon capture by a biotin-streptavidin interaction and detection with DIG-specific antiserum in a colorimetric ELISA. We evaluated the utility of this assay for detecting St. Louis encephalitis (SLE) viral RNA in infected mosquitoes and dengue viral RNA in human serum specimens. The reverse transcriptase-PCR-ELISA was as sensitive as isolation of SLE virus by cell culture in detecting SLE viral RNA in infected mosquitoes. The test was 89% specific and 95 to 100% sensitive for identification of dengue viral RNA in serum specimens compared with isolation of virus by Aedes albopictus C6/36 cell culture and identification by the indirect immunofluorescence assay.
Ambardekar, Shubha; Shochet, Tara; Bracken, Hillary; Coyaji, Kurus; Winikoff, Beverly
2014-08-15
Trials of interventions for PPH prevention and treatment rely on different measurement methods for the quantification of blood loss and identification of PPH. This study's objective was to compare measures of blood loss obtained from two different measurement protocols frequently used in studies. Nine hundred women presenting for vaginal delivery were randomized to a direct method (a calibrated delivery drape) or an indirect method (a shallow bedpan placed below the buttocks and weighing the collected blood and blood-soaked gauze/pads). Blood loss was measured from immediately after delivery for at least one hour or until active bleeding stopped. Significantly greater mean blood loss was recorded by the direct than by the indirect measurement technique (253.9 mL and 195.3 mL, respectively; difference = 58.6 mL (95% CI: 31-86); p < 0.001). Almost twice as many women in the direct than in the indirect group measured blood loss > 500 mL (8.7% vs. 4.7%, p = 0.02). The study suggests a real and significant difference in blood loss measurement between these methods. Research using blood loss measurement as an endpoint needs to be interpreted taking measurement technique into consideration. This study has been registered at clinicaltrials.gov as NCT01885845.
Flow Cytometry Detection of Infectious Rotaviruses in Environmental and Clinical Samples
Abad, F. Xavier; Pintó, Rosa M.; Bosch, Albert
1998-01-01
A method for the detection of infectious human rotaviruses based on infection of CaCo-2 cells and detection of infected cells by indirect immunofluorescence and flow cytometry (IIF-FC) has been developed. The technique was validated by performing a seminested reverse transcription-PCR assay with sorted cell populations. The efficiency of the procedure has been compared with that of the standard method of infection of MA104 cells and ulterior detection by IIF and optical microscopy (IIF-OM) and with that of infection of MA104 cells and detection by IIF-FC. The limit of sensitivity for the detection of the cell-adapted strain Itor P13, expressed as the most probable number of cytopathogenic units, was established as 200 and 2 for MA104 and CaCo-2 cells, respectively, by the IIF-FC method. The ratio of infectious virus particles to total virus particles for a wild-type rotavirus was determined to be 1/2 × 106 and 1/2 × 104 for IIF-OM with MA104 cells and IIF-FC with CaCo-2 cells, respectively. The use of IIF-FC with CaCo-2 cells was tested with fecal and water samples and proved to be more effective than the standard procedure for rotavirus detection. PMID:9647805
Gadkar, Vijay J; Goldfarb, David M; Gantt, Soren; Tilley, Peter A G
2018-04-03
Loop-mediated isothermal amplification (LAMP) is an isothermal nucleic acid amplification (iNAAT) technique known for its simplicity, sensitivity and speed. Its low-cost feature has resulted in its wide scale application, especially in low resource settings. The major disadvantage of LAMP is its heavy reliance on indirect detection methods like turbidity and non-specific dyes, which often leads to the detection of false positive results. In the present work, we have developed a direct detection approach, whereby a labelled loop probe quenched in its unbound state, fluoresces only when bound to its target (amplicon). Henceforth, referred to as Fluorescence of Loop Primer Upon Self Dequenching-LAMP (FLOS-LAMP), it allows for the sequence-specific detection of LAMP amplicons. The FLOS-LAMP concept was validated for rapid detection of the human pathogen, Varicella-zoster virus, from clinical samples. The FLOS-LAMP had a limit of detection of 500 copies of the target with a clinical sensitivity and specificity of 96.8% and 100%, respectively. The high level of specificity is a major advance and solves one of the main shortcomings of the LAMP technology, i.e. false positives. Self-quenching/de-quenching probes were further used with other LAMP primer sets and different fluorophores, thereby demonstrating its versatility and adaptability.
Marginal adaptation of CAD-CAM onlays: Influence of preparation design and impression technique.
Lima, Fernanda Ferruzzi; Neto, Constantino Fernandes; Rubo, José H; Santos, Gildo Coelho; Moraes Coelho Santos, Maria Jacinta
2018-03-15
Factors that may affect the marginal adaptation of computer-aided design and computer-aided manufacturing (CAD-CAM) restorations include preparation design, impression technique, and CAD-CAM system. The influence of impression technique and preparation design on CAD-CAM partial coverage restorations has not been fully addressed. The purpose of this in vitro study was to investigate the influence of direct and indirect digital impression techniques and 2 preparation designs on the marginal adaptation of CAD-CAM onlays. Two mesio-occlusal buccal onlay preparations with reduction of the mesiobuccal cusp were made: conventional preparation (CP) with a 1.2-mm modified shoulder margin and modified preparation (MP) flat cuspal reduction without shoulder. Virtual models were generated from each preparation by using a digital scanner (BlueCam; Dentsply Sirona) from the plastic teeth (direct digital impression) or from the stone dies (indirect digital impression). Onlays were designed using a CAD-CAM system (CEREC 4.0; Dentsply Sirona), and nanoceramic resin blocks (Lava Ultimate Restorative; 3M ESPE) were milled using the CEREC MCX milling machine. Marginal discrepancy was evaluated using an optical stereomicroscope at ×25 magnification in 18 locations distributed along the margins of the preparation. The data were analyzed by using 3-way ANOVA followed by the Tukey HSD test (α=.05). CP presented a statistically significant reduced average marginal adaptation (59 ±50 μm) than did MP (69 ±58 μm) (P<.001). The Tukey HSD test showed the presence of a significantly larger marginal discrepancy in the mesial and buccal locations of MP when compared with CP. Regarding impression techniques, the buccal location presented the smallest average marginal discrepancy in restorations fabricated with indirect impression when compared with direct impression (42 ±33 μm and 60 ±39 μm) (P<.001). The results showed that conventional preparation with a modified shoulder margin presented improved marginal adaptation compared with modified preparation with flat cuspal reduction. Direct and indirect digital impression techniques produced restorations within a clinically acceptable range; however, the indirect impression technique resulted in the fabrication of restorations with superior marginal adaptation on the buccal location. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Quantitation of dissolved gas content in emulsions and in blood using mass spectrometric detection.
Grimley, Everett; Turner, Nicole; Newell, Clayton; Simpkins, Cuthbert; Rodriguez, Juan
2011-06-01
Quantitation of dissolved gases in blood or in other biological media is essential for understanding the dynamics of metabolic processes. Current detection techniques, while enabling rapid and convenient assessment of dissolved gases, provide only direct information on the partial pressure of gases dissolved in the aqueous fraction of the fluid. The more relevant quantity known as gas content, which refers to the total amount of the gas in all fractions of the sample, can be inferred from those partial pressures, but only indirectly through mathematical modeling. Here we describe a simple mass spectrometric technique for rapid and direct quantitation of gas content for a wide range of gases. The technique is based on a mass spectrometer detector that continuously monitors gases that are rapidly extracted from samples injected into a purge vessel. The accuracy and sample processing speed of the system is demonstrated with experiments that reproduce within minutes literature values for the solubility of various gases in water. The capability of the technique is further demonstrated through accurate determination of O(2) content in a lipid emulsion and in whole blood, using as little as 20 μL of sample. The approach to gas content quantitation described here should greatly expand the range of animals and conditions that may be used in studies of metabolic gas exchange, and facilitate the development of artificial oxygen carriers and resuscitation fluids. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Jochum, K. P.; Seufert, H. M.
1995-09-01
We have developed new spark source mass spectrometric (SSMS) techniques for simultaneous analysis of platinum-group elements (PGE) together with other trace elements in stony meteorites. We have measured elemental abundances of Rh, Ru, Os, Ir, Pt, Au in carbonaceous chondrites of different types including the two CI chondrites Orgueil and Ivuna. These data are relevant for the determination of solar-system abundances. Whereas the solar-system abundances of most PGE are well known, this is not the case for Rh, and no literature data exist for carbonaceous chondrites, mainly because of analytical difficulties. The SSMS techniques include new calibration procedures and the use of a recently developed multi-ion counting (MIC) system [1]. The mono-isotopic element Rh and the other PGE were determined by using internal standard elements (e.g., Nd, U) that were measured by isotope dilution in the same sample electrode material. The data were calibrated with certified standard solutions of PGE which were doped on trace-element poor rock samples. Ion abundances were measured using both the conventional photoplate detection and the ion-counting techniques. The new MIC technique that uses up to 20 small channeltrons for ion counting measurements has the advantage of improved precision, detection limits and analysis time compared to photoplate detection. Tab. 1 shows the Rh analyses for the meteorites Orgueil, Ivuna, Murchison, Allende and Karoonda obtained by conventional photoplate detection. These are the first Rh results for carbonaceous chondrites. The data for the two CI chondrites Orgueil and Ivuna are identical and agree within 4 % with the CI estimate of Anders and Grevesse [2] which was derived indirectly from analyses for H-chondrites. The PGE Os, Ir, Pt, Au and W, Re, Th, U concentrations were determined by both detection systems. Data obtained with the MIC system are more precise (about 4% for concentrations in the ppb range) compared to the photoplate detection system (about 10 - 15 %). Both data sets agree within error limits. Rhodium correlates well with Pt and other PGE indicating no significant fractionation between the different types of carbonaceous chondrites (Tab. 1). References: [1] Jochum K. P. et al. (1994) Fresenius J. Anal. Chem., 350, 642-644. [2] Anders E. and Grevesse N. (1989) GCA, 53, 197-214.
ERIC Educational Resources Information Center
Floyd, Randy G.; Phaneuf, Robin L.; Wilczynski, Susan M.
2005-01-01
Indirect assessment instruments used during functional behavioral assessment, such as rating scales, interviews, and self-report instruments, represent the least intrusive techniques for acquiring information about the function of problem behavior. This article provides criteria for examining the measurement properties of these instruments…
A false start in the race against doping in sport: concerns with cycling's biological passport.
Hailey, Nicholas
2011-11-01
Professional cycling has suffered from a number of doping scandals. The sport's governing bodies have responded by implementing an aggressive new antidoping program known as the biological passport. Cycling's biological passport marks a departure from traditional antidoping efforts, which have focused on directly detecting prohibited substances in a cyclist's system. Instead, the biological passport tracks biological variables in a cyclist's blood and urine over time, monitoring for fluctuations that are thought to indirectly reveal the effects of doping. Although this method of indirect detection is promising, it also raises serious legal and scientific concerns. Since its introduction, the cycling community has debated the reliability of indirect biological-passport evidence and the clarity, consistency, and transparency of its use in proving doping violations. Such uncertainty undermines the legitimacy of finding cyclists guilty of doping based on this indirect evidence alone. Antidoping authorities should address these important concerns before continuing to pursue doping sanctions against cyclists solely on the basis of their biological passports.
Exposure measurement of aflatoxins and aflatoxin metabolites in human body fluids. A short review.
Leong, Yin-Hui; Latiff, Aishah A; Ahmad, Nurul Izzah; Rosma, Ahmad
2012-05-01
Aflatoxins are highly toxic secondary fungal metabolites mainly produced by Aspergillus flavus and A. parasiticus. Human exposure to aflatoxins may result directly from ingestion of contaminated foods, or indirectly from consumption of foods from animals previously exposed to aflatoxins in feeds. This paper focuses on exposure measurement of aflatoxins and aflatoxin metabolites in various human body fluids. Research on different metabolites present in blood, urine, breast milk, and other human fluids or tissues including their detection techniques is reviewed. The association between dietary intake of aflatoxins and biomarker measurement is also highlighted. Finally, aspects related to the differences between aflatoxin determination in food versus the biomarker approach are discussed.
Suchorab, Zbigniew; Barnat-Hunek, Danuta; Franus, Małgorzata; Łagód, Grzegorz
2016-01-01
This article is focused on lightweight aggregate-concrete modified by municipal sewage sludge and lightweight aggregate-concrete obtained from light aggregates. The article presents laboratory examinations of material physical parameters. Water absorptivity of the examined material was decreased by the admixture of water emulsion of reactive polysiloxanes. Water transport properties were determined using Time Domain Reflectometry, an indirect technique for moisture detection in porous media. Together with basic physical parameters, the heat conductivity coefficient λ was determined for both types of lightweight aggregate-concrete. Analysis of moisture and heat properties of the examined materials confirmed the usefulness of light aggregates supplemented with sewage sludge for prospective production. PMID:28773442
Sample size requirements for indirect association studies of gene-environment interactions (G x E).
Hein, Rebecca; Beckmann, Lars; Chang-Claude, Jenny
2008-04-01
Association studies accounting for gene-environment interactions (G x E) may be useful for detecting genetic effects. Although current technology enables very dense marker spacing in genetic association studies, the true disease variants may not be genotyped. Thus, causal genes are searched for by indirect association using genetic markers in linkage disequilibrium (LD) with the true disease variants. Sample sizes needed to detect G x E effects in indirect case-control association studies depend on the true genetic main effects, disease allele frequencies, whether marker and disease allele frequencies match, LD between loci, main effects and prevalence of environmental exposures, and the magnitude of interactions. We explored variables influencing sample sizes needed to detect G x E, compared these sample sizes with those required to detect genetic marginal effects, and provide an algorithm for power and sample size estimations. Required sample sizes may be heavily inflated if LD between marker and disease loci decreases. More than 10,000 case-control pairs may be required to detect G x E. However, given weak true genetic main effects, moderate prevalence of environmental exposures, as well as strong interactions, G x E effects may be detected with smaller sample sizes than those needed for the detection of genetic marginal effects. Moreover, in this scenario, rare disease variants may only be detectable when G x E is included in the analyses. Thus, the analysis of G x E appears to be an attractive option for the detection of weak genetic main effects of rare variants that may not be detectable in the analysis of genetic marginal effects only.
Towards the final word on neutralino dark matter
NASA Astrophysics Data System (ADS)
Bramante, Joseph; Desai, Nishita; Fox, Patrick; Martin, Adam; Ostdiek, Bryan; Plehn, Tilman
2016-03-01
We present a complete phenomenological prospectus for thermal relic neutralinos. Including Sommerfeld enhancements to relic abundance and halo annihilation calculations, we obtain direct, indirect, and collider discovery prospects for all neutralinos with mass parameters M1 , M2 , |μ |<4 TeV , which freeze out to the observed dark matter abundance, with scalar superpartners decoupled. Much of the relic neutralino sector will be uncovered by the direct detection experiments Xenon1T and LZ, as well as indirect detection with Cerenkov Telescope Array. We emphasize that thermal relic Higgsinos will be found by next-generation direct detection experiments, so long as M1 ,2<4 TeV . Charged tracks at a 100 TeV hadron collider complement indirect searches for relic winos. Thermal relic bino-winos still evade all planned experiments, including disappearing charged-track searches. However, they can be discovered by compressed electroweakino searches at a 100 TeV collider, completing the full coverage of the relic neutralino surface.
Towards the final word on neutralino dark matter
Bramante, Joseph; Desai, Nishita; Fox, Patrick; ...
2016-03-25
We present a complete phenomenological prospectus for thermal relic neutralinos. Including Sommerfeld enhancements to relic abundance and halo annihilation calculations, we obtain direct, indirect, and collider discovery prospects for all neutralinos with mass parametersmore » $$M_1,M_2,|\\mu| < 4$$ TeV, that freeze out to the observed dark matter abundance, with scalar superpartners decoupled. Much of the relic neutralino sector will be uncovered by the direct detection experiments Xenon1T and LZ, as well as indirect detection with CTA. We emphasize that thermal relic higgsinos will be found by next-generation direct detection experiments, so long as $$M_{1,2} < 4$$ TeV. Charged tracks at a 100 TeV hadron collider complement indirect searches for relic winos. Thermal relic bino-winos still evade all planned experiments, including disappearing charged-track searches. Furthermore, they can be discovered by compressed electroweakino searches at a 100 TeV collider, completing the full coverage of the relic neutralino surface.« less
Mirghani, Haïtham; Amen, Furrat; Moreau, Frederique; Guigay, Joel; Ferchiou, Malek; Melkane, Antoine E; Hartl, Dana M; Lacau St Guily, Jean
2014-01-01
High risk Human Papilloma virus (HR-HPV) associated oropharyngeal cancers are on the increase. Although, the scientific community is aware of the importance of Human Papilloma Virus (HPV) testing, there is no consensus on the assays that are required to reliably identify HR-HPV related tumors. A wide range of methods have been developed. The most widely used techniques include viral DNA detection, with polymerase chain reaction (PCR) or In Situ Hybridization, and p16 detected by immunohistochemistry. However, these tests provide different information and have their own specific limitations. In this review, we summarize these different techniques, in light of the recent literature. p16 Overexpression, which is an indirect marker of HPV infection, is considered by many head and neck oncologists to be the most important marker for patient stratification. We describe the frequent lack of concordance of this marker with other assays and the possible reasons for this. The latest developments in HPV testing are also reported, such as the RNAscope™ HPV test, and how they fit into the existing framework of techniques. HPV testing must not be considered in isolation, as there are important interactions with other parameters, such as tobacco exposure. This is an important and rapidly evolving field and is likely to become pivotal to staging and choice of treatment of oropharyngeal carcinoma in the future. Copyright © 2013 Elsevier Ltd. All rights reserved.
Yan, Yuling; Petchprayoon, Chutima; Mao, Shu; Marriott, Gerard
2013-01-01
Optical switch probes undergo rapid and reversible transitions between two distinct states, one of which may fluoresce. This class of probe is used in various super-resolution imaging techniques and in the high-contrast imaging technique of optical lock-in detection (OLID) microscopy. Here, we introduce optimized optical switches for studies in living cells under standard conditions of cell culture. In particular, a highly fluorescent cyanine probe (Cy or Cy3) is directly or indirectly linked to naphthoxazine (NISO), a highly efficient optical switch that undergoes robust, 405/532 nm-driven transitions between a colourless spiro (SP) state and a colourful merocyanine (MC) state. The intensity of Cy fluorescence in these Cy/Cy3-NISO probes is reversibly modulated between a low and high value in SP and MC states, respectively, as a result of Förster resonance energy transfer. Cy/Cy3-NISO probes are targeted to specific proteins in living cells where defined waveforms of Cy3 fluorescence are generated by optical switching of the SP and MC states. Finally, we introduce a new imaging technique (called OLID-immunofluorescence microscopy) that combines optical modulation of Cy3 fluorescence from Cy3/NISO co-labelled antibodies within fixed cells and OLID analysis to significantly improve image contrast in samples having high background or rare antigens. PMID:23267183
Indirect detection of neutrino portal dark matter
NASA Astrophysics Data System (ADS)
Batell, Brian; Han, Tao; Shams Es Haghi, Barmak
2018-05-01
We investigate the feasibility of the indirect detection of dark matter in a simple model using the neutrino portal. The model is very economical, with right-handed neutrinos generating neutrino masses through the type-I seesaw mechanism and simultaneously mediating interactions with dark matter. Given the small neutrino Yukawa couplings expected in a type-I seesaw, direct detection and accelerator probes of dark matter in this scenario are challenging. However, dark matter can efficiently annihilate to right-handed neutrinos, which then decay via active-sterile mixing through the weak interactions, leading to a variety of indirect astronomical signatures. We derive the existing constraints on this scenario from Planck cosmic microwave background measurements, Fermi dwarf spheroidal galaxy and Galactic center gamma-ray observations, and AMS-02 antiproton observations, and we also discuss the future prospects of Fermi and the Cherenkov Telescope Array. Thermal annihilation rates are already being probed for dark matter lighter than about 50 GeV, and this can be extended to dark matter masses of 100 GeV and beyond in the future. This scenario can also provide a dark matter interpretation of the Fermi Galactic center gamma-ray excess, and we confront this interpretation with other indirect constraints. Finally we discuss some of the exciting implications of extensions of the minimal model with large neutrino Yukawa couplings and Higgs portal couplings.
van 't Veer, Anna E; Gallucci, Marcello; Stel, Mariëlle; van Beest, Ilja
2015-01-01
A pre-registered experiment was conducted to examine psychophysiological responses to being lied to. Bridging research on social cognition and deception detection, we hypothesized that observing a liar compared to a truth-teller would decrease finger skin temperature of observers. Participants first watched two targets while not forewarned that they would later be asked to judge (direct and indirect) veracity, and then watched another two targets while forewarned about this. During both these phases finger skin temperature was measured. Findings pertaining to temperature partly confirmed our main hypothesis. When participants were observing a liar, irrespective of being forewarned, on average finger skin temperature declined over time. In the forewarned phase, temperature trajectories of truth-tellers were higher than those of liars, however, in the not forewarned phase, this pattern was reversed. Results confirmed our further hypotheses that participants judge liars as less likeable and less trustworthy than truth-tellers-an indication of indirect deception detection. Our hypothesis that the effect size for trustworthiness would be bigger than that of liking was not supported by the data. Additionally, and also confirming our hypothesis, participants performed around chance level when directly judging whether the target person was lying. Exploratory analyses are reported with regard to truth bias and dependency between direct and indirect veracity judgments. Limitations and directions for future work related to the existence of psychophysiological indicators of deception detection are discussed.
Brigo, Francesco; Bragazzi, Nicola; Nardone, Raffaele; Trinka, Eugen
2016-11-01
The aim of this study was to conduct a meta-analysis of published studies to directly compare intravenous (IV) levetiracetam (LEV) with IV phenytoin (PHT) or IV valproate (VPA) as second-line treatment of status epilepticus (SE), to indirectly compare intravenous IV LEV with IV VPA using common reference-based indirect comparison meta-analysis, and to verify whether results of indirect comparisons are consistent with results of head-to-head randomized controlled trials (RCTs) directly comparing IV LEV with IV VPA. Random-effects Mantel-Haenszel meta-analyses to obtain odds ratios (ORs) for efficacy and safety of LEV versus VPA and LEV or VPA versus PHT were used. Adjusted indirect comparisons between LEV and VPA were used. Two RCTs comparing LEV with PHT (144 episodes of SE) and 3 RCTs comparing VPA with PHT (227 episodes of SE) were included. Direct comparisons showed no difference in clinical seizure cessation, neither between VPA and PHT (OR: 1.07; 95% CI: 0.57 to 2.03) nor between LEV and PHT (OR: 1.18; 95% CI: 0.50 to 2.79). Indirect comparisons showed no difference between LEV and VPA for clinical seizure cessation (OR: 1.16; 95% CI: 0.45 to 2.97). Results of indirect comparisons are consistent with results of a recent RCT directly comparing LEV with VPA. The absence of a statistically significant difference in direct and indirect comparisons is due to the lack of sufficient statistical power to detect a difference. Conducting a RCT that has not enough people to detect a clinically important difference or to estimate an effect with sufficient precision can be regarded a waste of time and resources and may raise several ethical concerns, especially in RCT on SE. Copyright © 2016 Elsevier Inc. All rights reserved.
Sirichai, S; de Mello, A J
2001-01-01
The separation and detection of both print and film developing agents (CD-3 and CD-4) in photographic processing solutions using chip-based capillary electrophoresis is presented. For simultaneous detection of both analytes under identical experimental conditions a buffer pH of 11.9 is used to partially ionise the analytes. Detection is made possible by indirect fluorescence, where the ions of the analytes displace the anionic fluorescing buffer ion to create negative peaks. Under optimal conditions, both analytes can be analyzed within 30 s. The limits of detection for CD-3 and CD-4 are 0.17 mM and 0.39 mM, respectively. The applicability of the method for the analysis of seasoned photographic processing developer solutions is also examined.
Hart, James L; Lang, Andrew C; Leff, Asher C; Longo, Paolo; Trevor, Colin; Twesten, Ray D; Taheri, Mitra L
2017-08-15
In many cases, electron counting with direct detection sensors offers improved resolution, lower noise, and higher pixel density compared to conventional, indirect detection sensors for electron microscopy applications. Direct detection technology has previously been utilized, with great success, for imaging and diffraction, but potential advantages for spectroscopy remain unexplored. Here we compare the performance of a direct detection sensor operated in counting mode and an indirect detection sensor (scintillator/fiber-optic/CCD) for electron energy-loss spectroscopy. Clear improvements in measured detective quantum efficiency and combined energy resolution/energy field-of-view are offered by counting mode direct detection, showing promise for efficient spectrum imaging, low-dose mapping of beam-sensitive specimens, trace element analysis, and time-resolved spectroscopy. Despite the limited counting rate imposed by the readout electronics, we show that both core-loss and low-loss spectral acquisition are practical. These developments will benefit biologists, chemists, physicists, and materials scientists alike.
Sensitive detection of Escherichia coli O157:H7 based on cascade signal amplification in ELISA.
Shan, Shan; Liu, Daofeng; Guo, Qi; Wu, Songsong; Chen, Rui; Luo, Kai; Hu, Liming; Xiong, Yonghua; Lai, Weihua
2016-09-01
In this study, cascade signal amplification in ELISA involving double-antibody sandwich ELISA and indirectly competitive ELISA was established to sensitively detect Escherichia coli O157:H7. In the double-antibody sandwich ELISA, a complex was formed comprising anti-E. coli O157:H7 polyclonal antibody, E. coli O157:H7, biotinylated anti-E. coli O157:H7 monoclonal antibody, streptavidin, and biotinylated β-lactamase. Penicillin solution was then added into the ELISA well and hydrolyzed by β-lactamase. Afterward, the penicillin solution was transferred to indirectly competitive ELISA. The concentration of penicillin can be sensitively detected in indirectly competitive ELISA. In the cascade signal amplification system, increasing the amount of added E. coli O157:H7 resulted in more β-lactamase and less penicillin. The detection sensitivity of E. coli O157:H7, which was 20cfu/mL with the cascade signal amplification in ELISA, was 1,000-fold higher than that of traditional ELISA. Furthermore, the novel method can be used to detect E. coli O157:H7 in milk (2cfu/g). Therefore, this new signaling strategy will facilitate analyses of highly sensitive foodborne pathogens. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Elmore, Stacey A; Samelius, Gustaf; Al-Adhami, Batol; Huyvaert, Kathryn P; Bailey, Larissa L; Alisauskas, Ray T; Gajadhar, Alvin A; Jenkins, Emily J
2016-01-01
Although the protozoan parasite Toxoplasma gondii is ubiquitous in birds and mammals worldwide, the full suite of hosts and transmission routes is not completely understood, especially in the Arctic. Toxoplasma gondii occurrence in humans and wildlife can be high in Arctic regions, despite apparently limited opportunities for transmission of oocysts shed by felid definitive hosts. Arctic foxes (Vulpes lagopus) are under increasing anthropogenic and ecologic pressure, leading to population declines in parts of their range. Our understanding of T. gondii occurrence in arctic foxes is limited to only a few regions, but mortality events caused by this parasite have been reported. We investigated the exposure of arctic foxes to T. gondii in the Karrak Lake goose colony, Queen Maud Gulf Migratory Bird Sanctuary, Nunavut, Canada. Following an occupancy-modeling framework, we performed replicated antibody testing on serum samples by direct agglutination test (DAT), indirect fluorescent antibody test (IFAT), and an indirect enzyme-linked immunosorbent assay (ELISA) that can be used in multiple mammalian host species. As a metric of test performance, we then estimated the probability of detecting T. gondii antibodies for each of the tests. Occupancy estimates for T. gondii antibodies in arctic foxes under this framework were between 0.430 and 0.758. Detection probability was highest for IFAT (0.716) and lower for DAT (0.611) and ELISA (0.464), indicating that the test of choice for antibody detection in arctic foxes might be the IFAT. We document a new geographic record of T. gondii exposure in arctic foxes and demonstrate an emerging application of ecologic modeling techniques to account for imperfect performance of diagnostic tests in wildlife species.
Aramaki, T.; Boggs, S.; Bufalino, S.; ...
2016-01-27
Recent years have seen increased theoretical and experimental effort towards the first-ever detection of cosmic-ray antideuterons, in particular as an indirect signature of dark matter annihilation or decay. In contrast to indirect dark matter searches using positrons, antiprotons, or γ-rays, which suffer from relatively high and uncertain astrophysical backgrounds, searches with antideuterons benefit from very suppressed conventional backgrounds, offering a potential breakthrough in unexplored phase space for dark matter. This article is based on the first dedicated cosmic-ray antideuteron workshop, which was held at UCLA in June 2014. It reviews broad classes of dark matter candidates that result in detectablemore » cosmic-ray antideuteron fluxes, as well as the status and prospects of current experimental searches. The coalescence model of antideuteron production and the influence of antideuteron measurements at particle colliders are discussed. This is followed by a review of the modeling of antideuteron propagation through the magnetic fields, plasma currents, and molecular material of our Galaxy, the solar system, the Earth’s geomagnetic field, and the atmosphere. Lastly, the three ongoing or planned experiments that are sensitive to cosmic-ray antideuterons, BESS, AMS-02, and GAPS, are detailed. As cosmic-ray antideuteron detection is a rare event search, multiple experiments with orthogonal techniques and backgrounds are essential. Furthermore, the combination of AMS-02 and GAPS antideuteron searches is highly desirable. Many theoretical and experimental groups have contributed to these studies over the last decade, this review aims to provide the first coherent discussion of the relevant dark matter theories that antideuterons probe, the challenges to predictions and interpretations of antideuteron signals, and the experimental efforts toward cosmic antideuteron detection.« less
First Detection of Antibodies Against African Swine Fever Virus in Faeces Samples.
Nieto-Pelegrín, E; Rivera-Arroyo, B; Sánchez-Vizcaíno, J M
2015-12-01
African swine fever (ASF) is a viral, highly lethal haemorrhagic disease of swine with no available vaccine or effective treatment. Introduction of ASF into a country triggers immediate restriction measures that cause significant economic losses and threatens spread to neighbouring countries. Wild boar populations have been recently assigned an essential role in the spread of African swine fever virus (ASFV) to European countries. Therefore, effective surveillance and monitoring of wild boar populations is required, but sampling wild boar is logistically challenging and expensive. This study assessed the feasibility of detecting antibodies against ASFV in faeces for later implementation in surveillance and control programmes. Two groups of pigs were experimentally infected with an attenuated ASFV isolate Ken05, and blood, oral fluid and faecal samples were tested for the presence of viral DNA using quantitative real-time polymerase chain reaction (qPCR) to monitor infection progress. Faecal samples were analysed using two indirect enzyme-linked immunosorbent assays (ELISAs) based on semipurified viral protein (vp) 72 or purified recombinant vp30 expressed in mammalian cells. Faecal samples from 9 of 10 pigs with non-haemorrhagic diarrhoea tested positive for antibodies against ASFV using the two ELISA tests that showed a positive correlation. The serum sample results from the two indirect ELISAs were compared against results from the reference ELISA technique and the immunoperoxidase test. Our findings indicate the feasibility of faecal sampling for detecting anti-ASFV antibodies, which may provide a practical non-invasive alternative for sampling wild boar populations. In conclusion, the application of these ELISA tests to faecal field samples could be particularly useful to screen for the presence of ASF in field conditions. © 2015 Blackwell Verlag GmbH.
Using the Retrospective Pretest to Get Usable, Indirect Evidence of Student Learning
ERIC Educational Resources Information Center
Coulter, Shannon E.
2012-01-01
Minimal evidence exists regarding the retrospective pretest's effectiveness as a tool to obtain usable, indirect evidence of student learning in open admissions institutions. The researcher conducted this study to determine if a retrospective pretest more accurately detected a change in students' knowledge compared to a conventional…
PINPIN a-Si:H based structures for X-ray image detection using the laser scanning technique
NASA Astrophysics Data System (ADS)
Fernandes, M.; Vygranenko, Y.; Vieira, M.
2015-05-01
Conventional film based X-ray imaging systems are being replaced by their digital equivalents. Different approaches are being followed by considering direct or indirect conversion, with the later technique dominating. The typical, indirect conversion, X-ray panel detector uses a phosphor for X-ray conversion coupled to a large area array of amorphous silicon based optical sensors and a couple of switching thin film transistors (TFT). The pixel information can then be readout by switching the correspondent line and column transistors, routing the signal to an external amplifier. In this work we follow an alternative approach, where the electrical switching performed by the TFT is replaced by optical scanning using a low power laser beam and a sensing/switching PINPIN structure, thus resulting in a simpler device. The optically active device is a PINPIN array, sharing both front and back electrical contacts, deposited over a glass substrate. During X-ray exposure, each sensing side photodiode collects photons generated by the scintillator screen (560 nm), charging its internal capacitance. Subsequently a laser beam (445 nm) scans the switching diodes (back side) retrieving the stored charge in a sequential way, reconstructing the image. In this paper we present recent work on the optoelectronic characterization of the PINPIN structure to be incorporated in the X-ray image sensor. The results from the optoelectronic characterization of the device and the dependence on scanning beam parameters are presented and discussed. Preliminary results of line scans are also presented.
NASA Technical Reports Server (NTRS)
Wilkins, J. R. (Inventor)
1981-01-01
The growth of microorganisms in a sample is detected and monitored by culturing microorganisms in a growth medium and detecting a change in potential between two electrodes, separated from the microbial growth by a barrier which is permeable to charged paticles but microorganism impermeable.
Concurrent Ultrasonic Tomography and Acoustic Emission in Solid Materials
NASA Astrophysics Data System (ADS)
Chow, Thomas M.
A series of experiments were performed to detect stress induced changes in the elastic properties of various solid materials. A technique was developed where these changes were monitored concurrently by two methods, ultrasonic tomography and acoustic emission monitoring. This thesis discusses some experiments in which acoustic emission (AE) and ultrasonic tomography were performed on various samples of solid materials including rocks, concrete, metals, and fibre reinforced composites. Three separate techniques were used to induce stress in these samples. Disk shaped samples were subject to stress via diametral loading using an indirect tensile test geometry. Cylindrical samples of rocks and concrete were subject to hydraulic fracture tests, and rectangular samples of fibre reinforced composite were subject to direct tensile loading. The majority of the samples were elastically anisotropic. Full waveform acoustic emission and tomographic data were collected while these samples were under load to give information concerning changes in the structure of the material as it was undergoing stress change and/or failure. Analysis of this data indicates that AE and tomographic techniques mutually compliment each other to give a view of the stress induced elastic changes in the tested samples.
Kim, C-K; Joo, Y-T; Lee, E P; Park, Y K; Kim, H-J; Kim, S J
2013-09-01
The Korean Institute of Tuberculosis, Seoul, Republic of Korea. To develop a simple, direct drug susceptibility testing (DST) technique using Kudoh-modified Ogawa (KMO) medium. The critical concentrations of isoniazid (INH), rifampicin (RMP), kanamycin (KM) and ofloxacin (OFX) for KMO medium were calibrated by comparing the minimal inhibitory concentrations (MICs) against clinical isolates of Mycobacterium tuberculosis on KMO with those on Löwenstein-Jensen (LJ). The performance of the direct KMO DST technique was evaluated on 186 smear-positive sputum specimens and compared with indirect LJ DST. Agreement of MICs on direct vs. indirect DST was high for INH, RMP and OFX. KM MICs on KMO were ∼10 g/ml higher than those on LJ. The critical concentrations of INH, RMP, OFX and KM for KMO were therefore set at 0.2, 40.0, 2.0, and 40.0 g/ml. The evaluation of direct DST of smear-positive sputum specimens showed 100% agreement with indirect LJ DST for INH and RMP. However, the respective susceptible and resistant predictive values were 98.8% and 100% for OFX, and 100% and 80% for KM. Direct DST using KMO is useful, with clear advantages of a shorter turnaround time, procedural simplicity and low cost compared to indirect DST. It may be most indicated in resource-poor settings for programmatic management of drug-resistant tuberculosis.
48 CFR 1631.203-70 - Allocation techniques.
Code of Federal Regulations, 2010 CFR
2010-10-01
... shall consistently apply the methods and techniques established to classify direct and indirect costs... meant to be exhaustive, but rather are examples of allocation methods that may be acceptable under... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Allocation techniques. 1631...
NASA Astrophysics Data System (ADS)
Chen, Hao; De Feyter, Henk M.; Brown, Peter B.; Rothman, Douglas L.; Cai, Shuhui; de Graaf, Robin A.
2017-10-01
A wide range of direct 13C and indirect 1H-[13C] MR detection methods exist to probe dynamic metabolic pathways in the human brain. Choosing an optimal detection method is difficult as sequence-specific features regarding spatial localization, broadband decoupling, spectral resolution, power requirements and sensitivity complicate a straightforward comparison. Here we combine density matrix simulations with experimentally determined values for intrinsic 1H and 13C sensitivity, T1 and T2 relaxation and transmit efficiency to allow selection of an optimal 13C MR detection method for a given application and magnetic field. The indirect proton-observed, carbon-edited (POCE) detection method provides the highest accuracy at reasonable RF power deposition both at 4 T and 7 T. The various polarization transfer methods all have comparable performances, but may become infeasible at 7 T due to the high RF power deposition. 2D MR methods have limited value for the metabolites considered (primarily glutamate, glutamine and γ-amino butyric acid (GABA)), but may prove valuable when additional information can be extracted, such as isotopomers or lipid composition. While providing the lowest accuracy, the detection of non-protonated carbons is the simplest to implement with the lowest RF power deposition. The magnetic field homogeneity is one of the most important parameters affecting the detection accuracy for all metabolites and all acquisition methods.
Kilimcioğlu, Ali A; Ozkol, Mine; Bayindir, Petek; Girginkardeşler, Nogay; Ostan, Ipek; Ok, Ulgen Z
2006-12-01
A total of 1,205 primary school children were examined for cystic echinococcosis in five villages of Manisa, Turkey, to evaluate the efficacy of diagnostic methods of this infection in community-based screening surveys. Six hundred and thirty children from three villages, examined by a portable ultrasound scanner, chest microfilm and serological methods (ELISA, indirect hemagglutination) in our previous study, were designated as Study Group 1; and 575 children, from two adjacent villages, examined by ultrasonography alone in the present study, were designated as Study Group 2. In Study Group 1, hepatic cystic echinococcosis was detected in two cases (0.3%) by ultrasonography, while 43 (8.9%) and 49 (10.1%) cases were found to be positive for cystic echinococcosis by ELISA and indirect hemagglutination, respectively. Three of 575 children (0.5%) were diagnosed with cystic echinococcosis (two hepatic and one renal involvement) by ultrasonography alone in Study Group 2; and lung lesions were later detected in both cases with liver involvement by chest radiography. Our results suggested that serological tests may be beneficial in suspected cases for confirmation and differential diagnosis, but have some drawbacks, such as discrepancy in results and high false seropositivity rates. Chest microfilm is not easy in field studies and exposure to X-ray is undesirable. As a reliable, simple, inexpensive and rapid technique, ultrasonography alone is recommended to be used in community-based screening surveys for cystic echinococcosis with confirmatory tests for suspected cases found during the screening program.
NASA Astrophysics Data System (ADS)
Arneitz, Patrick; Egli, Ramon; Leonhardt, Roman
2017-03-01
Reconstructions of the past geomagnetic field provide fundamental constraints for understanding the dynamics of the Earth's interior, as well as serving as basis for magnetostratigraphic and archeomagnetic dating tools. Such reconstructions, when extending over epochs that precede the advent of instrumental measurements, rely exclusively on magnetic records from archeological artifacts, and, further in the past, from rocks and sediments. The most critical component of such indirect records is field intensity because of possible biases introduced by material properties and by laboratory protocols, which do not reproduce exactly the original field recording conditions. Large biases are usually avoided by the use of appropriate checking procedures; however, smaller ones can remain undetected in individual studies and might significantly affect field reconstructions. We introduce a new general approach for analyzing geomagnetic databases in order to investigate the reliability of indirect records. This approach is based on the comparison of historical records with archeomagnetic and volcanic data, considering temporal and spatial mismatches with adequate weighting functions and error estimation. A good overall agreement is found between indirect records and historical measurements, while for several subsets systematic bias is detected (e.g., inclination shallowing of lava records). We also demonstrate that simple approaches to analyzing highly inhomogeneous and internally correlated paleomagnetic data sets can lead to incorrect conclusions about the efficiency of quality checks and corrections. Consistent criteria for selecting and weighting data are presented in this review and can be used to improve current geomagnetic field modeling techniques.
Low dose digital X-ray imaging with avalanche amorphous selenium
NASA Astrophysics Data System (ADS)
Scheuermann, James R.; Goldan, Amir H.; Tousignant, Olivier; Léveillé, Sébastien; Zhao, Wei
2015-03-01
Active Matrix Flat Panel Imagers (AMFPI) based on an array of thin film transistors (TFT) have become the dominant technology for digital x-ray imaging. In low dose applications, the performance of both direct and indirect conversion detectors are limited by the electronic noise associated with the TFT array. New concepts of direct and indirect detectors have been proposed using avalanche amorphous selenium (a-Se), referred to as high gain avalanche rushing photoconductor (HARP). The indirect detector utilizes a planar layer of HARP to detect light from an x-ray scintillator and amplify the photogenerated charge. The direct detector utilizes separate interaction (non-avalanche) and amplification (avalanche) regions within the a-Se to achieve depth-independent signal gain. Both detectors require the development of large area, solid state HARP. We have previously reported the first avalanche gain in a-Se with deposition techniques scalable to large area detectors. The goal of the present work is to demonstrate the feasibility of large area HARP fabrication in an a-Se deposition facility established for commercial large area AMFPI. We also examine the effect of alternative pixel electrode materials on avalanche gain. The results show that avalanche gain > 50 is achievable in the HARP layers developed in large area coaters, which is sufficient to achieve x-ray quantum noise limited performance down to a single x-ray photon per pixel. Both chromium (Cr) and indium tin oxide (ITO) have been successfully tested as pixel electrodes.
Novel genotype of Ehrlichia canis detected in samples of human blood bank donors in Costa Rica.
Bouza-Mora, Laura; Dolz, Gaby; Solórzano-Morales, Antony; Romero-Zuñiga, Juan José; Salazar-Sánchez, Lizbeth; Labruna, Marcelo B; Aguiar, Daniel M
2017-01-01
This study focuses on the detection and identification of DNA and antibodies to Ehrlichia spp. in samples of blood bank donors in Costa Rica using molecular and serological techniques. Presence of Ehrlichia canis was determined in 10 (3.6%) out of 280 blood samples using polymerase chain reaction (PCR) targeting the ehrlichial dsb conserved gene. Analysis of the ehrlichial trp36 polymorphic gene in these 10 samples revealed substantial polymorphism among the E. canis genotypes, including divergent tandem repeat sequences. Nucleotide sequences of dsb and trp36 amplicons revealed a novel genotype of E. canis in blood bank donors from Costa Rica. Indirect immunofluorescence assay (IFA) detected antibodies in 35 (35%) of 100 serum samples evaluated. Thirty samples showed low endpoint titers (64-256) to E. canis, whereas five sera yielded high endpoint titers (1024-8192); these five samples were also E. canis-PCR positive. These findings represent the first report of the presence of E. canis in humans in Central America. Copyright © 2016 Elsevier GmbH. All rights reserved.
Engineering of a DNA Polymerase for Direct m6 A Sequencing.
Aschenbrenner, Joos; Werner, Stephan; Marchand, Virginie; Adam, Martina; Motorin, Yuri; Helm, Mark; Marx, Andreas
2018-01-08
Methods for the detection of RNA modifications are of fundamental importance for advancing epitranscriptomics. N 6 -methyladenosine (m 6 A) is the most abundant RNA modification in mammalian mRNA and is involved in the regulation of gene expression. Current detection techniques are laborious and rely on antibody-based enrichment of m 6 A-containing RNA prior to sequencing, since m 6 A modifications are generally "erased" during reverse transcription (RT). To overcome the drawbacks associated with indirect detection, we aimed to generate novel DNA polymerase variants for direct m 6 A sequencing. Therefore, we developed a screen to evolve an RT-active KlenTaq DNA polymerase variant that sets a mark for N 6 -methylation. We identified a mutant that exhibits increased misincorporation opposite m 6 A compared to unmodified A. Application of the generated DNA polymerase in next-generation sequencing allowed the identification of m 6 A sites directly from the sequencing data of untreated RNA samples. © 2017 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.
Wide-band analog frequency modulation of optic signals using indirect techniques
NASA Technical Reports Server (NTRS)
Fitzmartin, D. J.; Balboni, E. J.; Gels, R. G.
1991-01-01
The wideband frequency modulation (FM) of an optical carrier by a radio frequency (RF) or microwave signal can be accomplished independent of laser type when indirect modulation is employed. Indirect modulators exploit the integral relation of phase to frequency so that phase modulators can be used to impress frequency modulation on an optical carrier. The use of integrated optics phase modulators, which are highly linear, enables the generation of optical wideband FM signals with very low intermodulation distortion. This modulator can be used as part of an optical wideband FM link for RF and microwave signals. Experimental results from the test of an indirect frequency modulator for an optical carrier are discussed.
Derchi, Giacomo; Vano, Michele; Barone, Antonio; Covani, Ugo; Diaspro, Alberto; Salerno, Marco
2017-05-01
Both direct and indirect techniques are used for dental restorations. Which technique should be preferred or whether they are equivalent with respect to bacterial adhesion is unclear. The purpose of this in vitro study was to determine the affinity of bacterial biofilm to dental restorative composite resins placed directly and indirectly. Five direct composite resins for restorations (Venus Diamond, Adonis, Optifil, Enamel Plus HRi, Clearfil Majesty Esthetic) and 3 indirect composite resins (Gradia, Estenia, Signum) were selected. The materials were incubated in unstimulated whole saliva for 1 day. The biofilms grown were collected and their bacterial cells counted. In parallel, the composite resin surface morphology was analyzed with atomic force microscopy. Both bacterial cell count and surface topography parameters were subjected to statistical analysis (α=.05). Indirect composite resins showed significantly lower levels than direct composite resins for bacterial cell adhesion, (P<.001). No significant differences were observed within the direct composite resins (P>.05). However, within the indirect composite resins a significantly lower level was found for Gradia than Estenia or Signum (P<.01). A partial correlation was observed between composite resin roughness and bacterial adhesion when the second and particularly the third-order statistical moments of the composite resin height distributions were considered. Indirect dental restorative composite resins were found to be less prone to biofilm adhesion than direct composite resins. A correlation of bacterial adhesion to surface morphology exists that is described by kurtosis; thus, advanced data analysis is required to discover possible insights into the biologic effects of morphology. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Etienne, A-L; Audigié, F; Peeters, D; Gabriel, A; Busoni, V
2015-04-01
Cisternal puncture in dogs and cats is commonly carried out. This article describes the percutaneous ultrasound anatomy of the cisternal region in the dog and the cat and an indirect technique for ultrasound-guided cisternal puncture. Ultrasound images obtained ex vivo and in vivo were compared with anatomic sections and used to identify the landmarks for ultrasound-guided cisternal puncture. The ultrasound-guided procedure was established in cadavers and then applied in vivo in seven dogs and two cats. The anatomic landmarks for the ultrasound-guided puncture are the cisterna magna, the spinal cord, the two occipital condyles on transverse images, the external occipital crest and the dorsal arch of the first cervical vertebra on longitudinal images. Using these ultrasound anatomic landmarks, an indirect ultrasound-guided technique for cisternal puncture is applicable in the dog and the cat. © 2014 Blackwell Verlag GmbH.
An Indirect Data Assimilation Scheme for Deep Soil Temperature in the Pleim-Xiu Land Surface Model
The Pleim-Xiu land surface model (PX LSM) has been improved by the addition of a 2nd indirect data assimilation scheme. The first, which was described previously, is a technique where soil moisture in nudged according to the biases in 2-m air temperature and relative humidity be...
Estimating forest canopy bulk density using six indirect methods
Robert E. Keane; Elizabeth D. Reinhardt; Joe Scott; Kathy Gray; James Reardon
2005-01-01
Canopy bulk density (CBD) is an important crown characteristic needed to predict crown fire spread, yet it is difficult to measure in the field. Presented here is a comprehensive research effort to evaluate six indirect sampling techniques for estimating CBD. As reference data, detailed crown fuel biomass measurements were taken on each tree within fixed-area plots...
ERIC Educational Resources Information Center
Kim, Young-Mi; Neff, James Alan
2010-01-01
A model incorporating the direct and indirect effects of parental monitoring on adolescent alcohol use was evaluated by applying structural equation modeling (SEM) techniques to data on 4,765 tenth-graders in the 2001 Monitoring the Future Study. Analyses indicated good fit of hypothesized measurement and structural models. Analyses supported both…
A Robust Approach to Constraining Dark Matter from Gamma-Ray Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baxter, Eric J.; /Chicago U., Astron. Astrophys. Ctr.; Dodelson, Scott
2011-03-01
Photons produced in the annihilations of dark matter particles can be detected by gamma-ray telescopes; this technique of indirect detection serves as a cornerstone of the upcoming assault on the dark matter paradigm. The main obstacle to the extraction of information about dark matter from the annihilation photons is the presence of large and uncertain gamma-ray backgrounds. We present a new technique for using gamma-ray data to constrain the properties of dark matter that makes minimal assumptions about the dark matter and the backgrounds. The technique relies on two properties of the expected signal from annihilations of the smooth darkmore » matter component in our Galaxy: (1) it is approximately rotationally symmetric around the axis connecting us to the Galactic center, and (2) variations from the mean signal are uncorrelated from one pixel to the next. We apply this technique to recent data from the Fermi telescope to generate constraints on the dark matter mass and cross section for a variety of annihilation channels. We quantify the uncertainty introduced into our constraints by uncertainties in the halo profile and by the possibility that the halo is triaxial. The resultant constraint, the flux F {le} 4.5 x 10{sup -6} cm{sup -2} s{sup -1} sr{sup -1} for energies between 1 and 100 GeV at an angle 15{sup o} away from the Galactic center, translates into an upper limit on the velocity-weighted annihilation cross section of order 10{sup -25} cm{sup 3} s{sup -1}, depending on the annihilation mode.« less
Shen, Ming; Trébosc, J; Lafon, O; Pourpoint, F; Hu, Bingwen; Chen, Qun; Amoureux, J-P
2014-08-01
Connectivities and proximities between protons and low-gamma nuclei can be probed in solid-state NMR spectroscopy using two-dimensional (2D) proton-detected heteronuclear correlation, through Heteronuclear Multiple Quantum Correlation (HMQC) pulse sequence. The indirect detection via protons dramatically enhances the sensitivity. However, the spectra are often broadened along the indirect F1 dimension by the decay of heteronuclear multiple-quantum coherences under the strong (1)H-(1)H dipolar couplings. This work presents a systematic comparison of the performances of various decoupling schemes during the indirect t1 evolution period of dipolar-mediated HMQC (D-HMQC) experiment. We demonstrate that (1)H-(1)H dipolar decoupling sequences during t1, such as symmetry-based schemes, phase-modulated Lee-Goldburg (PMLG) and Decoupling Using Mind-Boggling Optimization (DUMBO), provide better resolution than continuous wave (1)H irradiation. We also report that high resolution requires the preservation of (1)H isotropic chemical shifts during the decoupling sequences. When observing indirectly broad spectra presenting numerous spinning sidebands, the D-HMQC sequence must be fully rotor-synchronized owing to the rotor-synchronized indirect sampling and dipolar recoupling sequence employed. In this case, we propose a solution to reduce artefact sidebands caused by the modulation of window delays before and after the decoupling application during the t1 period. Moreover, we show that (1)H-(1)H dipolar decoupling sequence using Smooth Amplitude Modulation (SAM) minimizes the t1-noise. The performances of the various decoupling schemes are assessed via numerical simulations and compared to 2D (1)H-{(13)C} D-HMQC experiments on [U-(13)C]-L-histidine⋅HCl⋅H2O at various magnetic fields and Magic Angle spinning (MAS) frequencies. Great resolution and sensitivity enhancements resulting from decoupling during t1 period enable the detection of heteronuclear correlation between aliphatic protons and ammonium (14)N sites in L-histidine⋅HCl⋅H2O. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Tsao, Yu-Chia; Yang, Yi-Wen; Tsai, Woo-Hu; Yan, Tsong-Rong
2008-02-01
Side-polished fiber immunosensor based on surface plasmon resonance (SPR) onto self-assembled protein A layer was proposed for the detection of Legionella pneumophila. A self-assembled protein A layer on gold (Au) surface was fabricated by adsorbing a mixture of 11-mercaptoundecanoic acid (MUA) and activated by N-Ethyl-N'-(3-dimethylaminopropyl) carbodiimide/ N-Hydroxysuccinimide (EDC/NHS). The formation of self-assembled protein A and gold layer on side-polished surface and the binding of antibody and antigen in series were confirmed by SPR response on spectrum. The binding protein A layer can improve the sensitivity, which indirectly supports the configurations that antibody layer is immobilized on the binding protein A layer with a well-ordered orientation. The surface morphology analyses of self-assembled protein A layer on Au substrate and monoclonal antibody against L. pneumophila immobilized on protein A were demonstrated by SPR dip shifts on optical spectrum analyzer. The SPR fiber immunosensor for detection of L. pneumophila was developed and the detection limit was 10 CFU/ml with the SPR dip shift in wavelength from 1070 to 1105nm. The current fabrication technique of a SPR immunosensor using optical fiber for the detection of Legionella pneumophila could be applied to construct other biosensor.
Nanoplasmonic biochips for rapid label-free detection of imidacloprid pesticides with a smartphone.
Lee, Kuang-Li; You, Meng-Lin; Tsai, Chia-Hsin; Lin, En-Hung; Hsieh, Shu-Yi; Ho, Ming-Hsun; Hsu, Ju-Chun; Wei, Pei-Kuen
2016-01-15
The widespread and intensive use of neonicotinoid insecticides induces negative cascading effects on ecosystems. It is desirable to develop a portable sensitive sensing platform for on-site screening of high-risk pesticides. We combined an indirect competitive immunoassay, highly sensitive surface plasmon resonance (SPR) biochip and a simple portable imaging setup for label-free detection of imidacloprid pesticides. The SPR biochip consists of several capped nanoslit arrays with different periods which form a spectral image on the chip. The qualitative and semiquantitative analyses of pesticides can be directly observed from the spot shift on the chip. The precise semiquantitative analyses can be further completed by using image processing in a smartphone. We demonstrate simultaneous detection of four different concentrations of imidacloprid pesticides. The visual detection limit is about 1ppb, which is well below the maximum residue concentration permitted by law (20ppb). Compared to the one-step strip assay, the proposed chip is capable of performing semiquantitative analyses and multiple detection. Compared to the enzyme-linked immunosorbent assay, our method is label-free and requires simple washing steps and short reaction time. In addition, the label-free chip has a comparable sensitivity but wider working range than those labeling techniques. Copyright © 2015 Elsevier B.V. All rights reserved.
Development of an enzyme-linked immunosorbent assay for the detection of dicamba.
Clegg, B S; Stephenson, G R; Hall, J C
2001-05-01
A competitive indirect enzyme-linked immunosorbent assay (CI-ELISA) was developed to quantitate the herbicide dicamba (3,6-dichloro-2-methoxybenzoic acid) in water. The CI-ELISA has a detection limit of 2.3 microg L(-1) and a linear working range of 10--10000 microg L(-1) with an IC(50) value of 195 microg L(-1). The dicamba polyclonal antisera did not cross-react with a number of other herbicides tested but did cross-react with a dicamba metabolite, 5-hydroxydicamba, and structurally related chlorobenzoic acids. The assay was used to estimate quantitatively dicamba concentrations in water samples. Water samples were analyzed directly, and no sample preparation was required. To improve detection limits, a C(18) (reversed phase) column concentration step was devised prior to analysis, and the detection limits were increased by at least by 10-fold. After the sample preconcentration, the detection limit, IC(50), and linear working range were 0.23, 19.5, and 5-200 microg L(-1), respectively. The CI-ELISA estimations in water correlated well with those from gas chromatography-mass spectrometry (GC-MS) analysis (r(2) = 0.9991). This assay contributes to reducing laboratory costs associated with the conventional GC-MS residue analysis techniques for the quantitation of dicamba in water.
Fluorescent detection of C-reactive protein using polyamide beads
NASA Astrophysics Data System (ADS)
Jagadeesh, Shreesha; Chen, Lu; Aitchison, Stewart
2016-03-01
Bacterial infection causes Sepsis which is one of the leading cause of mortality in hospitals. This infection can be quantified from blood plasma using C - reactive protein (CRP). A quick diagnosis at the patient's location through Point-of- Care (POC) testing could give doctors the confidence to prescribe antibiotics. In this paper, the development and testing of a bead-based procedure for CRP quantification is described. The size of the beads enable them to be trapped in wells without the need for magnetic methods of immobilization. Large (1.5 mm diameter) Polyamide nylon beads were used as the substrate for capturing CRP from pure analyte samples. The beads captured CRP either directly through adsorption or indirectly by having specific capture antibodies on their surface. Both methods used fluorescent imaging techniques to quantify the protein. The amount of CRP needed to give a sufficient fluorescent signal through direct capture method was found suitable for identifying bacterial causes of infection. Similarly, viral infections could be quantified by the more sensitive indirect capture method. This bead-based assay can be potentially integrated as a disposable cartridge in a POC device due to its passive nature and the small quantities needed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bonneville, Alain H.; Kouzes, Richard T.
Imaging subsurface geological formations, oil and gas reservoirs, mineral deposits, cavities or magma chambers under active volcanoes has been for many years a major quest of geophysicists and geologists. Since these objects cannot be observed directly, different indirect geophysical methods have been developed. They are all based on variations of certain physical properties of the subsurface that can be detected from the ground surface or from boreholes. Electrical resistivity, seismic wave’s velocities and density are certainly the most used properties. If we look at density, indirect estimates of density distributions are performed currently by seismic reflection methods - since themore » velocity of seismic waves depend also on density - but they are expensive and discontinuous in time. Direct estimates of density are performed using gravimetric data looking at variations of the gravity field induced by the density variations at depth but this is not sufficiently accurate. A new imaging technique using cosmic-ray muon detectors has emerged during the last decade and muon tomography - or muography - promises to provide, for the first time, a complete and precise image of the density distribution in the subsurface. Further, this novel approach has the potential to become a direct, real-time, and low-cost method for monitoring fluid displacement in subsurface reservoirs.« less
Production of monoclonal antibody to acaricide dicofol and its derivatives.
Hongsibsong, Surat; Prapamontol, Tippawan; Suphavilai, Chaisuree; Wipasa, Jiraprapa; Pattarawarapan, Mookda; Kasinrerk, Watchara
2010-12-01
In Thailand detection of acaricide dicofol residues has been sporadically performed due to the limitation of analytical techniques. Conventional analytical methods for detecting dicofol residues most often use chromatographic-based techniques. Our ultimate aim is to develop an alternative method for rapidly analyzing dicofol residues in vegetables and fruit samples. Here we report the production of monoclonal antibodies specific to dicofol and its derivatives. Hapten-protein carriers were prepared by linking succinic anhydride to dichlorobenzhydrol (DCBH), which was then conjugated to bovine serum albumin (BSA) and oval albumin (OVA). DCBH-BSA conjugate was used as immunogen while DCBH-OVA conjugate was used as capture antigen for competitive inhibition assay. Female BALB/c mice were immunized with DCBH-BSA conjugate subcutaneously, and antibody (Ab) level was determined 2 weeks after the last immunization. Spleen cells producing high titer antibody were isolated and fused with myeloma cells of P3.X6.Ag8.653. After limiting dilutions, antibody produced by one clone had high affinity, which was found to be of IgG1 with κ light chain. Specificity and inhibition concentrations of the monoclonal antibody (MAb) were determined by competitive indirect ELISA with dicofol, and its 50% (IC(50)) was 0.28 μg/mL. Working ranges of the developed immunoassay were from 0.07 to 25 μg/mL. Hence, the prepared MAb will be able to be applied for immunoassay development for detecting dicofol residue in vegetables and fruits far below the maximum residue limit such that 5 g of fruits and berries can be detected below 0.1 mg/kg.
One-day fluorescent-antibody procedure for detecting salmonellae in frozen and dried foods.
Goepfert, J M; Mann, M E; Hicks, R
1970-12-01
The indirect fluorescent-antibody technique was used to examine 422 food samples for the presence of salmonellae. A cultural phase involving a 16-hr preenrichment in buffered nutrient broth-milk medium followed by a 4- to 5-hr subculture into fresh medium of the same composition was evaluated. This procedure yielded a sufficient population of salmonellae so that no false-negative results were obtained. Of the 31 false-positives obtained, 12 samples yielded positive cultural results upon extensive subculture of the original enrichment broths. Yeast cells and both vegetative and spore forms of bacilli were observed to fluoresce when stained with anti-Salmonella serum. Efforts to ascertain the cause of these cross-reactions and several alternate explanations are discussed.
Myers, T J; Schat, K A; Mockett, A P
1989-01-01
Immunoglobulin class-specific enzyme-linked immunosorbent assays were developed for detecting antibodies against avian rotavirus in serum, intestinal contents, and bile from experimentally infected specific-pathogen-free (SPF) chickens. Both indirect and antibody-capture (AbC) assays were developed based on monoclonal antibodies specific for chicken IgG, IgM, and IgA. Treatment of purified rotavirus with sodium thiocyanate before coating the plate improved the rotavirus-specific reading in the indirect assay. Use of Immunolon 2 plates facilitated attachment of monoclonal antibodies to the plate in the AbC assay. Addition of 5% powdered skim milk to the diluent buffer reduced nonspecific background readings. The indirect assay was superior for detecting rotavirus-specific IgG, whereas the AbC assay was better for detecting rotavirus-specific IgM and IgA. The presence of intestinal contents in the assay wells did not reduce the measurable titers of IgG, IgM, or IgA. These assays showed that SPF chickens produced systemic and mucosal antibodies against avian rotavirus.
Sakamoto, Seiichi; Kohno, Toshitaka; Shimizu, Kuniyoshi; Tanaka, Hiroyuki; Morimoto, Satoshi
2016-05-01
Ganoderma is a genus of medicinal mushroom traditionally used for treating various diseases. Ganoderic acid A is one of the major bioactive Ganoderma triterpenoids isolated from Ganoderma species. Herein, we produced a highly specific monoclonal antibody against ganoderic acid A (MAb 12 A) and developed an indirect competitive ELISA for the highly sensitive detection of ganoderic acid A in Ganoderma lingzhi, with a limit of detection of 6.10 ng/mL. Several validation analyses support the accuracy and reliability of the developed indirect competitive ELISA for use in the quality control of Ganoderma based on ganoderic acid A content. Furthermore, quantitative analysis of ganoderic acid A in G. lingzhi revealed that the pileus exhibits the highest ganoderic acid A content compared with the stipe and spore of the fruiting body; the best extraction efficiency was found when 50 % ethanol was used, which suggests the use of a strong liquor to completely harness the potential of Ganoderma triterpenoids in daily life. Georg Thieme Verlag KG Stuttgart · New York.
Nissan, Joseph; Oz-Ari, Beni; Gross, Ora; Ghelfan, Oded; Chaushu, Gavriel
2011-06-01
The aim of this long-term study was to compare the need for prosthetic aftercare of direct vs. indirect attachment incorporation techniques to mandibular implant-supported overdenture. Forty-five consecutive patients were included (130 implants were placed). Treatment was randomly allocated, resulting in 22 patients (group A) to be treated with direct ball attachment incorporation and 23 patients (group B) to be treated with indirect ball attachment incorporation. All patients were treated by experienced oral-maxillofacial surgeons/periodontists and experienced prosthodontists/residents. From the first day that the patients visited the clinic up to 20 years after the first treatment session, all surgical or prosthetic therapeutic interventions were recorded. The recorded data for the present study included the number of aftercare visits and dental treatment received (pressure sores relieve, liner changes due to loss of retention and attachment replacement due to wear). The mean follow-up was 93±57 months. No implants were lost. Statistical analysis revealed a statistically significantly (P<0.001) greater need for prosthetic interventions in group B vs. group A. The mean number of visits dedicated to - pressure sores relieve (7.04±1.4 vs. 3.63±0.84); liner exchange due to loss of retention (3.6±1.3 vs. 1.09±1.06) was significantly higher in group B. Attachment replacement due to wear occurred only in group B (11/23 - 47.8%). The direct technique for attachment incorporation in mandibular implant-supported overdentures using ball attachments is superior to the indirect technique from the aftercare perspective during a long-term evaluation period. © 2010 John Wiley & Sons A/S.
Speckle noise reduction in SAR images ship detection
NASA Astrophysics Data System (ADS)
Yuan, Ji; Wu, Bin; Yuan, Yuan; Huang, Qingqing; Chen, Jingbo; Ren, Lin
2012-09-01
At present, there are two types of method to detect ships in SAR images. One is a direct detection type, detecting ships directly. The other is an indirect detection type. That is, it firstly detects ship wakes, and then seeks ships around wakes. The two types all effect by speckle noise. In order to improve the accuracy of ship detection and get accurate ship and ship wakes parameters, such as ship length, ship width, ship area, the angle of ship wakes and ship outline from SAR images, it is extremely necessary to remove speckle noise in SAR images before data used in various SAR images ship detection. The use of speckle noise reduction filter depends on the specification for a particular application. Some common filters are widely used in speckle noise reduction, such as the mean filter, the median filter, the lee filter, the enhanced lee filter, the Kuan filter, the frost filter, the enhanced frost filter and gamma filter, but these filters represent some disadvantages in SAR image ship detection because of the various types of ship. Therefore, a mathematical function known as the wavelet transform and multi-resolution analysis were used to localize an SAR ocean image into different frequency components or useful subbands, and effectively reduce the speckle in the subbands according to the local statistics within the bands. Finally, the analysis of the statistical results are presented, which demonstrates the advantages and disadvantages of using wavelet shrinkage techniques over standard speckle filters.
Indirect competitive assays on DVD for direct multiplex detection of drugs of abuse in oral fluids.
Zhang, Lingling; Li, Xiaochun; Li, Yunchao; Shi, Xiaoli; Yu, Hua-Zhong
2015-02-03
On-site oral fluid testing for drugs of abuse has become prominent in order to take immediate administrative action in an enforcement process. Herein, we report a DVD technology-based indirect competitive immunoassay platform for the quantitative detection of drugs of abuse. A microfluidic approach was adapted to prepare multiplex immunoassays on a standard DVD-R, an unmodified multimode DVD/Blu-Ray drive to read signal, and a free disc-quality analysis software program to process the data. The DVD assay platform was successfully demonstrated for the simultaneous, quantitative detection of drug candidates (morphine and cocaine) in oral fluids with high selectivity. The detection limit achieved was as low as 1.0 ppb for morphine and 5.0 ppb for cocaine, comparable with that of standard mass spectrometry and ELISA methods.
Random phase detection in multidimensional NMR.
Maciejewski, Mark W; Fenwick, Matthew; Schuyler, Adam D; Stern, Alan S; Gorbatyuk, Vitaliy; Hoch, Jeffrey C
2011-10-04
Despite advances in resolution accompanying the development of high-field superconducting magnets, biomolecular applications of NMR require multiple dimensions in order to resolve individual resonances, and the achievable resolution is typically limited by practical constraints on measuring time. In addition to the need for measuring long evolution times to obtain high resolution, the need to distinguish the sign of the frequency constrains the ability to shorten measuring times. Sign discrimination is typically accomplished by sampling the signal with two different receiver phases or by selecting a reference frequency outside the range of frequencies spanned by the signal and then sampling at a higher rate. In the parametrically sampled (indirect) time dimensions of multidimensional NMR experiments, either method imposes an additional factor of 2 sampling burden for each dimension. We demonstrate that by using a single detector phase at each time sample point, but randomly altering the phase for different points, the sign ambiguity that attends fixed single-phase detection is resolved. Random phase detection enables a reduction in experiment time by a factor of 2 for each indirect dimension, amounting to a factor of 8 for a four-dimensional experiment, albeit at the cost of introducing sampling artifacts. Alternatively, for fixed measuring time, random phase detection can be used to double resolution in each indirect dimension. Random phase detection is complementary to nonuniform sampling methods, and their combination offers the potential for additional benefits. In addition to applications in biomolecular NMR, random phase detection could be useful in magnetic resonance imaging and other signal processing contexts.
Detection of Zaire ebolavirus in swine: Assay development and optimization.
Pickering, B S; Collignon, B; Smith, G; Marszal, P; Kobinger, G; Weingartl, H M
2018-02-01
Ebolaviruses (family Filoviridae, order Mononegavirales) cause often fatal, haemorrhagic fever in primates including humans. Pigs have been identified as a species susceptible to Reston ebolavirus (RESTV) infection, with indicated transmission to humans in the Philippines; however, their role during Ebola outbreaks in Africa needs to be clarified. To perform surveillance studies, detection of ebolavirus requires a prerequisite validation of viral RNA and antibody detection methods in swine samples. These diagnostic tests also need to be suitable for deployment to low-level containment laboratories. In this study, we developed a set of tests for detection of antibodies against Zaire ebolavirus (EBOV) in swine. Recombinant EBOV nucleoprotein was produced using a baculovirus expression system for indirect ELISA development. Evaluation of this assay was performed using laboratory and field samples, achieving a diagnostic specificity of 99%. Importantly, the indirect ELISA was able to detect antibodies to EBOV at 7 dpi, 3 days earlier than virus neutralization tests (VNT). The format of the VNT in this work was modified to a microtitre plaque reduction neutralization assay (miPRNT) complemented with immunostaining to provide a more rapid and highly specific assay. Finally, a confirmatory immunoblot assay was generated to supplement the indirect ELISA results. © 2017 Her Majesty the Queen in Right of Canada Reproduced with the permission of the Minister of Health and Agriculture, Canadian Food Inspection Agency.
Bender, Kimberly A; DePrince, Anne; Begun, Stephanie; Hathaway, Jessica; Haffejee, Badiah; Schau, Nicholas
2016-03-02
Homeless youth frequently experience victimization, and youth with histories of trauma often fail to detect danger risks, making them vulnerable to subsequent victimization. The current study describes a pilot test of a skills-based intervention designed to improve risk detection among homeless youth through focusing attention to internal, interpersonal, and environmental cues. Youth aged 18 to 21 years (N = 74) were recruited from a shelter and randomly assigned to receive usual case management services or usual services plus a 3-day manualized risk detection intervention. Pretest and posttest interviews assessed youths' risk detection abilities through vignettes describing risky situations and asking youth to identify risk cues present. Separate 2 (intervention vs. control) × 2 (pretest vs. posttest) mixed ANOVAs found significant interaction effects, as intervention youth significantly improved in overall risk detection compared with control youth. Post hoc subgroup analyses found the intervention had a greater effect for youth without previous experiences of indirect victimization than those with previous indirect victimization experiences. © The Author(s) 2016.
Wu, Xin-Lan; Yu, Shu-Juan; Kang, Ke-Ren
2015-03-01
In this study, an indirect competitive enzyme-linked immunoassay (ic-ELISA) based on monoclonal antibody for 4(5)-Methylimidazole (4-MI) detection was described. The artificial antigens were prepared by conjugating bovine serum albumin (BSA) or ovalbumin (OVA) with the hapten of 4-MI. And monoclonal antibody, evaluated by ic-ELISA, was obtained by immunizing BABL/c mice. After optimizing, a standard curve for ic-ELISA detection on 4-MI was obtained with the linear detection range of 0.64-20.48 mg/L. The cross-reactivity (CR) of all the structural analogues of 4-MI was less than 5.62%. The recoveries of 4-MI in caramels detection were ranged from 88.69% to 114.09%, with relative standard deviation (n=3) below 8.07%. The results suggested that the established ic-ELISA is promising for 4-MI commercial detection in caramels. Copyright © 2014 Elsevier Ltd. All rights reserved.
Helminth parasitic infections of the central nervous system: a diagnostic approach.
Othman, Ahmad A; Bruschi, Fabrizio; Ganna, Ahmed A
2014-04-01
Helminth parasitic infections of the central nervous system (CNS) occur worldwide with high prevalence in tropical and subtropical countries. Clinical evaluation of patients is mandatory, and it is convenient to group the clinical manifestations into syndromes: for example space-occupying lesions, meningitis, and encephalitis. The history should focus on residence or travel to endemic areas, diet, activities, intercurrent medical conditions, and associated clinical clues. Direct parasitological diagnosis can be reached by cerebrospinal fluid and cerebral tissue examination either by microscopy, culture, or immunological techniques. Immunodiagnosis by detection of parasite antibodies or antigens in serum could provide indirect evidence of parasitic infections. In addition, various imaging and radiological techniques e.g., computed tomography (CT) scan and magnetic resonance imaging (MRI) complement the diagnostic work-up of CNS diseases. Finally, the helminthic CNS infections of global impact, such as schistosomiasis, neurotoxocariasis, Strongyloides infection, neurotrichinosis, neurocysticercosis, and echinococcosis will be briefly discussed as regards the principal clinical and diagnostic features.
Aircraft Wake Vortex Measurements at Denver International Airport
NASA Technical Reports Server (NTRS)
Dougherty, Robert P.; Wang, Frank Y.; Booth, Earl R.; Watts, Michael E.; Fenichel, Neil; D'Errico, Robert E.
2004-01-01
Airport capacity is constrained, in part, by spacing requirements associated with the wake vortex hazard. NASA's Wake Vortex Avoidance Project has a goal to establish the feasibility of reducing this spacing while maintaining safety. Passive acoustic phased array sensors, if shown to have operational potential, may aid in this effort by detecting and tracking the vortices. During August/September 2003, NASA and the USDOT sponsored a wake acoustics test at the Denver International Airport. The central instrument of the test was a large microphone phased array. This paper describes the test in general terms and gives an overview of the array hardware. It outlines one of the analysis techniques that is being applied to the data and gives sample results. The technique is able to clearly resolve the wake vortices of landing aircraft and measure their separation, height, and sinking rate. These observations permit an indirect estimate of the vortex circulation. The array also provides visualization of the vortex evolution, including the Crow instability.
An Indirect Technique for the Measurement of Changes in Black Identity
ERIC Educational Resources Information Center
Condie, J. Spencer; Christiansen, James W.
1977-01-01
In order to indirectly measure the impact of the black power movement in terms of any shifts in identity and self-concept within the black community a content analysis was made of 272 issues of "Ebony" magazine published between January, 1949 and December, 1972 to determine any significant changes in the number of advertisements for cosmetics.…
Brussee, Brianne E.; Coates, Peter S.; Dwight, Ian; Young, Laura G.
2017-01-01
During 2011, four separate instances of indirect filial cannibalism, whereby adults consumed their young that died from unknown causes, were observed using video-monitoring techniques in a nesting colony of Black-crowned Night-Herons (Nycticorax nycticorax) on Alcatraz Island. Though they were not observed actively killing their young, in all four observations adult Black-crowned Night-Herons consumed their young following death (i.e., indirect filial cannibalism). We could not determine cause of chick mortality, but parental neglect was likely a contributing factor in at least two instances. Indirect filial cannibalism is not commonly documented among birds, and understanding how cannibalism contributes to nest failure can help researchers better understand factors that limit nesting populations.
Quantitative high dynamic range beam profiling for fluorescence microscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitchell, T. J., E-mail: t.j.mitchell@dur.ac.uk; Saunter, C. D.; O’Nions, W.
2014-10-15
Modern developmental biology relies on optically sectioning fluorescence microscope techniques to produce non-destructive in vivo images of developing specimens at high resolution in three dimensions. As optimal performance of these techniques is reliant on the three-dimensional (3D) intensity profile of the illumination employed, the ability to directly record and analyze these profiles is of great use to the fluorescence microscopist or instrument builder. Though excitation beam profiles can be measured indirectly using a sample of fluorescent beads and recording the emission along the microscope detection path, we demonstrate an alternative approach where a miniature camera sensor is used directly withinmore » the illumination beam. Measurements taken using our approach are solely concerned with the illumination optics as the detection optics are not involved. We present a miniature beam profiling device and high dynamic range flux reconstruction algorithm that together are capable of accurately reproducing quantitative 3D flux maps over a large focal volume. Performance of this beam profiling system is verified within an optical test bench and demonstrated for fluorescence microscopy by profiling the low NA illumination beam of a single plane illumination microscope. The generality and success of this approach showcases a widely flexible beam amplitude diagnostic tool for use within the life sciences.« less
Dark Matter Limits from Dwarf Spheroidal Galaxies with the HAWC Gamma-Ray Observatory
NASA Astrophysics Data System (ADS)
Albert, A.; Alfaro, R.; Alvarez, C.; Álvarez, J. D.; Arceo, R.; Arteaga-Velázquez, J. C.; Avila Rojas, D.; Ayala Solares, H. A.; Bautista-Elivar, N.; Becerril, A.; Belmont-Moreno, E.; BenZvi, S. Y.; Bernal, A.; Braun, J.; Brisbois, C.; Caballero-Mora, K. S.; Capistrán, T.; Carramiñana, A.; Casanova, S.; Castillo, M.; Cotti, U.; Cotzomi, J.; Coutiño de León, S.; De León, C.; De la Fuente, E.; Diaz Hernandez, R.; Dingus, B. L.; DuVernois, M. A.; Díaz-Vélez, J. C.; Ellsworth, R. W.; Engel, K.; Fiorino, D. W.; Fraija, N.; García-González, J. A.; Garfias, F.; González, M. M.; Goodman, J. A.; Hampel-Arias, Z.; Harding, J. P.; Hernandez, S.; Hernandez-Almada, A.; Hona, B.; Hüntemeyer, P.; Iriarte, A.; Jardin-Blicq, A.; Joshi, V.; Kaufmann, S.; Kieda, D.; Lauer, R. J.; Lennarz, D.; León Vargas, H.; Linnemann, J. T.; Longinotti, A. L.; Longo Proper, M.; Raya, G. Luis; Luna-García, R.; López-Coto, R.; Malone, K.; Marinelli, S. S.; Martinez-Castellanos, I.; Martínez-Castro, J.; Martínez-Huerta, H.; Matthews, J. A.; Miranda-Romagnoli, P.; Moreno, E.; Mostafá, M.; Nellen, L.; Newbold, M.; Nisa, M. U.; Noriega-Papaqui, R.; Pelayo, R.; Pretz, J.; Pérez-Pérez, E. G.; Ren, Z.; Rho, C. D.; Rivière, C.; Rosa-González, D.; Rosenberg, M.; Ruiz-Velasco, E.; Salesa Greus, F.; Sandoval, A.; Schneider, M.; Schoorlemmer, H.; Sinnis, G.; Smith, A. J.; Springer, R. W.; Surajbali, P.; Taboada, I.; Tibolla, O.; Tollefson, K.; Torres, I.; Vianello, G.; Weisgarber, T.; Westerhoff, S.; Wood, J.; Yapici, T.; Younk, P. W.; Zhou, H.
2018-02-01
The High Altitude Water Cherenkov (HAWC) gamma-ray observatory is a wide field of view observatory sensitive to 500 GeV–100 TeV gamma-rays and cosmic rays. It can also perform diverse indirect searches for dark matter annihilation and decay. Among the most promising targets for the indirect detection of dark matter are dwarf spheroidal galaxies. These objects are expected to have few astrophysical sources of gamma-rays but high dark matter content, making them ideal candidates for an indirect dark matter detection with gamma-rays. Here we present individual limits on the annihilation cross section and decay lifetime for 15 dwarf spheroidal galaxies within the field of view, as well as their combined limit. These are the first limits on the annihilation cross section and decay lifetime using data collected with HAWC. We also present the HAWC flux upper limits of the 15 dwarf spheroidal galaxies in half-decade energy bins.
Indirect searches for dark matter with the Fermi large area telescope
Albert, Andrea
2015-03-24
There is overwhelming evidence that non-baryonic dark matter constitutes ~ 27% of the energy density of the Universe. Weakly Interacting Massive Particles (WIMPs) are promising dark matter candidates that may produce γ rays via annihilation or decay detectable by the Fermi Large Area Telescope (LAT). A detection of WIMPs would also indicate the existence of physics beyond the Standard Model. We present recent results from the two cleanest indirect WIMP searches by the Fermi-LAT Collaboration: searches for γ-ray spectral lines and γ-ray emission associated with Milky Way dwarf spheroidal satellite galaxies.
Minding the MeV gap: The indirect detection of low mass dark matter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boddy, Kimberly K.; Kumar, Jason, E-mail: jkumar@hawaii.edu
2016-06-21
We consider the prospects for the indirect detection of low mass dark matter which couples dominantly to quarks. If the center of mass energy is below about 280 MeV, the kinematically allowed final states will be dominated by photons and neutral pions, producing striking signatures at gamma ray telescopes. In fact, an array of new instruments have been proposed, which would greatly improve sensitivity to photons in this energy range. We find that planned instruments can improve on current sensitivity to dark matter models of this type by up to a few orders of magnitude.
Development of a computational technique to measure cartilage contact area.
Willing, Ryan; Lapner, Michael; Lalone, Emily A; King, Graham J W; Johnson, James A
2014-03-21
Computational measurement of joint contact distributions offers the benefit of non-invasive measurements of joint contact without the use of interpositional sensors or casting materials. This paper describes a technique for indirectly measuring joint contact based on overlapping of articular cartilage computer models derived from CT images and positioned using in vitro motion capture data. The accuracy of this technique when using the physiological nonuniform cartilage thickness distribution, or simplified uniform cartilage thickness distributions, is quantified through comparison with direct measurements of contact area made using a casting technique. The efficacy of using indirect contact measurement techniques for measuring the changes in contact area resulting from hemiarthroplasty at the elbow is also quantified. Using the physiological nonuniform cartilage thickness distribution reliably measured contact area (ICC=0.727), but not better than the assumed bone specific uniform cartilage thicknesses (ICC=0.673). When a contact pattern agreement score (s(agree)) was used to assess the accuracy of cartilage contact measurements made using physiological nonuniform or simplified uniform cartilage thickness distributions in terms of size, shape and location, their accuracies were not significantly different (p>0.05). The results of this study demonstrate that cartilage contact can be measured indirectly based on the overlapping of cartilage contact models. However, the results also suggest that in some situations, inter-bone distance measurement and an assumed cartilage thickness may suffice for predicting joint contact patterns. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ma2 antibodies: an evaluation of commercially available detection methods.
Johannis, Wibke; Renno, Joerg H; Wielckens, Klaus; Voltz, Raymond
2011-01-01
Ma2 antibodies belong to the onconeuronal antibodies which define a "definite" paraneoplastic neurological syndrome (PNS). Because of the clinical relevance, use of two separate methods (indirect immunofluorescence technique--IFT--and immunoblot) is advocated; however, with an increasing number of commercially available assay systems, usually only one assay is performed. We compared IFT and three commercially available immunoblots (ravo Diagnostika, Euroimmun, Milenia Biotec) on sera from 35 patients with clinically suspected PNS. 17 were Ma2 antibody associated as defined by consensus result (showing positive reactivity in 2 assays), 18 were Ma2 antibody negative controls. Sensitivity/specificity for single assays were for IFT 94%/94%, for ravo Diagnostika PNS blot 88%/100%, for Euroimmun Neuronal Antigens Profile blot 100%/89%, and for Milenia Biotec MTR blot 94%/100%. Our data confirm, although all tests performed well, a combination of 2 independent assays is still advisable for Ma2 antibody detection in order to achieve higher sensitivity and specificity rates.
NASA Technical Reports Server (NTRS)
Pyle, Barry H.; Mcfeters, Gordon A.
1992-01-01
A number of microbiological issues are of critical importance to crew health and system performance in spacecraft water systems. This presentation reviews an army of these concerns which include factors that influence water treatment and disinfection in spaceflight such as biofilm formation and the physiological responses of bacteria in clean water systems. Factors associated with spaceflight like aerosol formation under conditions of microgravity are also discussed within the context of airborne infections such as Legionellosis. Finally, a spectrum of analytical approaches is reviewed to provide an evaluation of methodological alternatives that have been suggested or used to detect microorganisms of interest in water systems. These range from classical approaches employing colony formation on specific microbiological growth media to direct (i.e. microscopic) and indirect (e.g. electrochemical) methods as well as the use of molecular approaches and gene probes. These techniques are critically evaluated for their potential utility in determining microbiological water quality through the detection of microorganisms under the influence of ambient environmental stress inherent in spaceflight water systems.
Schönhuber, Wilhelm; Zarda, Boris; Eix, Stella; Rippka, Rosmarie; Herdman, Michael; Ludwig, Wolfgang; Amann, Rudolf
1999-01-01
Individual cyanobacterial cells are normally identified in environmental samples only on the basis of their pigmentation and morphology. However, these criteria are often insufficient for the differentiation of species. Here, a whole-cell hybridization technique is presented that uses horseradish peroxidase (HRP)-labeled, rRNA-targeted oligonucleotides for in situ identification of cyanobacteria. This indirect method, in which the probe-conferred enzyme has to be visualized in an additional step, was necessary since fluorescently monolabeled oligonucleotides were insufficient to overstain the autofluorescence of the target cells. Initially, a nonfluorescent detection assay was developed and successfully applied to cyanobacterial mats. Later, it was demonstrated that tyramide signal amplification (TSA) resulted in fluorescent signals far above the level of autofluorescence. Furthermore, TSA-based detection of HRP was more sensitive than that based on nonfluorescent substrates. Critical points of the assay, such as cell fixation and permeabilization, specificity, and sensitivity, were systematically investigated by using four oligonucleotides newly designed to target groups of cyanobacteria. PMID:10049892
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, K.; Itow, Y.; Rott, C., E-mail: koun@stelab.nagoya-u.ac.jp, E-mail: rott@skku.edu, E-mail: itow@stelab.nagoya-u.ac.jp
Dark matter could be captured in the Sun and self-annihilate, giving rise to an observable neutrino flux. Indirect searches for dark matter looking for this signal with neutrino telescopes have resulted in tight constraints on the interaction cross-section of dark matter with ordinary matter. We investigate how robust limits are against astro-physical uncertainties. We study the effect of the velocity distribution of dark matter in our Galaxy on capture rates in the Sun. We investigate four sources of uncertainties: orbital speed of the Sun, escape velocity of dark matter from the halo, dark matter velocity distribution functions and existence ofmore » a dark disc. We find that even extreme cases currently discussed do not decrease the sensitivity of indirect detection significantly because the capture is achieved over a broad range of the velocity distribution by integration over the velocity distribution. The effect of the uncertainty in the high-velocity tail of dark matter halo is very marginal as the capture process is rather inefficient at this region. The difference in capture rate in the Sun for various scenarios is compared to the expected change in event rates for direct detection. The possibility of co-rotating structure with the Sun can largely boost the signal and hence makes the interpretation of indirect detection conservative compared to direct detection.« less
NASA Astrophysics Data System (ADS)
Franco, Ana Paula G. O.; Karam, Leandro Z.; Galvão, José R.; Kalinowski, Hypolito J.
2015-09-01
The aim of the present study was evaluate the shrinkage polymerization and temperature of different acrylic resins used to splinting transfer copings in indirect impression technique. Two implants were placed in an artificial bone, with the two transfer copings joined with dental floss and acrylic resins; two dental resins are used. Measurements of deformation and temperature were performed with Fiber Braggs grating sensor for 17 minutes. The results revealed that one type of resin shows greater values of polymerization shrinkage than the other. Pattern resins did not present lower values of shrinkage, as usually reported by the manufacturer.
Testing and Comparison of Imaging Detectors for Electrons in the Energy Range 10-20 keV
NASA Astrophysics Data System (ADS)
Matheson, J.; Moldovan, G.; Kirkland, A.; Allinson, N.; Abrahams, J. P.
2017-11-01
Interest in direct detectors for low-energy electrons has increased markedly in recent years. Detection of electrons in the energy range up to low tens of keV is important in techniques such as photoelectron emission microscopy (PEEM) and electron backscatter diffraction (EBSD) on scanning electron microscopes (SEMs). The PEEM technique is used both in the laboratory and on synchrotron light sources worldwide. The ubiquity of SEMs means that there is a very large market for EBSD detectors for materials studies. Currently, the most widely used detectors in these applications are based on indirect detection of incident electrons. Examples include scintillators or microchannel plates (MCPs), coupled to CCD cameras. Such approaches result in blurring in scintillators/phosphors, distortions in optical systems, and inefficiencies due the limited active area of MCPs. In principle, these difficulties can be overcome using direct detection in a semiconductor device. Growing out of a feasibility study into the use of a direct detector for use on an XPEEM, we have built at Rutherford Appleton Laboratory a system to illuminate detectors with an electron beam of energy up to 20 keV . We describe this system in detail. It has been used to measure the performance of a custom back-thinned monolithic active pixel sensor (MAPS), a detector based on the Medipix2 chip, and a commercial detector based on MCPs. We present a selection of the results from these measurements and compare and contrast different detector types.
A study on real-time low-quality content detection on Twitter from the users' perspective.
Chen, Weiling; Yeo, Chai Kiat; Lau, Chiew Tong; Lee, Bu Sung
2017-01-01
Detection techniques of malicious content such as spam and phishing on Online Social Networks (OSN) are common with little attention paid to other types of low-quality content which actually impacts users' content browsing experience most. The aim of our work is to detect low-quality content from the users' perspective in real time. To define low-quality content comprehensibly, Expectation Maximization (EM) algorithm is first used to coarsely classify low-quality tweets into four categories. Based on this preliminary study, a survey is carefully designed to gather users' opinions on different categories of low-quality content. Both direct and indirect features including newly proposed features are identified to characterize all types of low-quality content. We then further combine word level analysis with the identified features and build a keyword blacklist dictionary to improve the detection performance. We manually label an extensive Twitter dataset of 100,000 tweets and perform low-quality content detection in real time based on the characterized significant features and word level analysis. The results of our research show that our method has a high accuracy of 0.9711 and a good F1 of 0.8379 based on a random forest classifier with real time performance in the detection of low-quality content in tweets. Our work therefore achieves a positive impact in improving user experience in browsing social media content.
A study on real-time low-quality content detection on Twitter from the users’ perspective
Yeo, Chai Kiat; Lau, Chiew Tong; Lee, Bu Sung
2017-01-01
Detection techniques of malicious content such as spam and phishing on Online Social Networks (OSN) are common with little attention paid to other types of low-quality content which actually impacts users’ content browsing experience most. The aim of our work is to detect low-quality content from the users’ perspective in real time. To define low-quality content comprehensibly, Expectation Maximization (EM) algorithm is first used to coarsely classify low-quality tweets into four categories. Based on this preliminary study, a survey is carefully designed to gather users’ opinions on different categories of low-quality content. Both direct and indirect features including newly proposed features are identified to characterize all types of low-quality content. We then further combine word level analysis with the identified features and build a keyword blacklist dictionary to improve the detection performance. We manually label an extensive Twitter dataset of 100,000 tweets and perform low-quality content detection in real time based on the characterized significant features and word level analysis. The results of our research show that our method has a high accuracy of 0.9711 and a good F1 of 0.8379 based on a random forest classifier with real time performance in the detection of low-quality content in tweets. Our work therefore achieves a positive impact in improving user experience in browsing social media content. PMID:28793347
ERIC Educational Resources Information Center
Powledge, Tabitha M.
1997-01-01
Describes techniques for delving into the brain including positron emission tomography (PET), single photon emission computed tomography (SPECT), electroencephalogram (EEG), magnetoencephalography (MEG), transcranial magnetic stimulation (TMS), and low-tech indirect studies. (JRH)
Decadal trends in marine reserves reveal differential rates of change in direct and indirect effects
Babcock, R.C.; Shears, N.T.; Alcala, A.C.; Barrett, N.S.; Edgar, G.J.; Lafferty, K.D.; McClanahan, T.R.; Russ, G.R.
2010-01-01
Decadal-scale observations of marine reserves suggest that indirect effects on taxa that occur through cascading trophic interactions take longer to develop than direct effects on target species. Combining and analyzing a unique set of long-term time series of ecologic data in and out of fisheries closures from disparate regions, we found that the time to initial detection of direct effects on target species (+ or -SE) was 5.13 + or - 1.9 years, whereas initial detection of indirect effects on other taxa, which were often trait mediated, took significantly longer (13.1 + or - 2.0 years). Most target species showed initial direct effects, but their trajectories over time were highly variable. Many target species continued to increase, some leveled off, and others decreased. Decreases were due to natural fluctuations, fishing impacts from outside reserves, or indirect effects from target species at higher trophic levels. The average duration of stable periods for direct effects was 6.2 + or - 1.2 years, even in studies of more than 15 years. For indirect effects, stable periods averaged 9.1 + or - 1.6 years, although this was not significantly different from direct effects. Populations of directly targeted species were more stable in reserves than in fished areas, suggesting increased ecologic resilience. This is an important benefit of marine reserves with respect to their function as a tool for conservation and restoration.
Babcock, R C; Shears, N T; Alcala, A C; Barrett, N S; Edgar, G J; Lafferty, K D; McClanahan, T R; Russ, G R
2010-10-26
Decadal-scale observations of marine reserves suggest that indirect effects on taxa that occur through cascading trophic interactions take longer to develop than direct effects on target species. Combining and analyzing a unique set of long-term time series of ecologic data in and out of fisheries closures from disparate regions, we found that the time to initial detection of direct effects on target species (±SE) was 5.13 ± 1.9 years, whereas initial detection of indirect effects on other taxa, which were often trait mediated, took significantly longer (13.1 ± 2.0 years). Most target species showed initial direct effects, but their trajectories over time were highly variable. Many target species continued to increase, some leveled off, and others decreased. Decreases were due to natural fluctuations, fishing impacts from outside reserves, or indirect effects from target species at higher trophic levels. The average duration of stable periods for direct effects was 6.2 ± 1.2 years, even in studies of more than 15 years. For indirect effects, stable periods averaged 9.1 ± 1.6 years, although this was not significantly different from direct effects. Populations of directly targeted species were more stable in reserves than in fished areas, suggesting increased ecologic resilience. This is an important benefit of marine reserves with respect to their function as a tool for conservation and restoration.
Gaze Direction Detection in Autism Spectrum Disorder
ERIC Educational Resources Information Center
Forgeot d'Arc, Baudouin; Delorme, Richard; Zalla, Tiziana; Lefebvre, Aline; Amsellem, Frédérique; Moukawane, Sanaa; Letellier, Laurence; Leboyer, Marion; Mouren, Marie-Christine; Ramus, Franck
2017-01-01
Detecting where our partners direct their gaze is an important aspect of social interaction. An atypical gaze processing has been reported in autism. However, it remains controversial whether children and adults with autism spectrum disorder interpret indirect gaze direction with typical accuracy. This study investigated whether the detection of…
A quantum dot-based immunoassay for screening of tylosin and tilmicosin in edible animal tissues.
Le, Tao; Zhu, Liqian; Yang, Xian
2015-01-01
A rapid, indirect competitive fluorescence-linked immunosorbent assay (ic-FLISA) based on quantum dots (QDs) as the fluorescent marker was developed for the detection of tylosin and tilmicosin in edible animal tissues. The end point fluorescent detection system was carried out using QDs conjugated with goat anti-mouse secondary antibody. The limits of detection (LODs) for the determination of tylosin and tilmicosin were 0.02 and 0.04 μg kg(-1), respectively. This detection method was used to analyse spiked samples and the recoveries ranged from 83.5% to 98.7% for tylosin and from 81.8% to 98.2% for tilmicosin. In real porcine tissue sample analysis, the results of ic-FLISA were similar to those obtained from an indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) to an HPLC method indicating its potential for tylosin and tilmicosin screening in edible animal tissues.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thornton, Michelle
Capillary electrophoresis (CE) is an effective method for separating ionic species according to differences in their electrophoretic mobilities. CE separations of amino acids by direct detection are difficult due to their similar electrophoretic mobilities and low absorbances. However, native amino acids can be separated by CE as cations at a low pH by adding an alkanesulfonic acid to the electrolyte carrier which imparts selectivity to the system. Derivatization is unnecessary when direct UV detection is used at 185 nm. Simultaneous speciation of metal cations such as vanadium (IV) and vanadium (V) can easily be performed without complexation prior to analysis.more » An indirect UV detection scheme for acidic conditions was also developed using guanidine as the background carrier electrolyte (BCE) for the indirect detection of metal cations. Three chapters have been removed for separate processing. This report contains introductory material, references, and general conclusions. 80 refs.« less
NASA Astrophysics Data System (ADS)
Cho, Jaedu; Kim, Chang-Seok; Gulsen, Gultekin
2016-03-01
Near-infrared fluorescence imaging (NIRF) is a powerful wide-field optical imaging tool that has a potential to visualize molecular-specific exogenous fluorescence agents, such as FDA approved Indocyanine Green (ICG), in thick tissue. Indeed, ICG is sensitive to biochemical environment such that it can be used to detect micro- or macroscopic environmental changes in tissue by solvatochromic shift that is defined by the dependence of absorption and emission spectra with the solvent polarity. For example, dimethyl sulfoxide (DMSO) is a very powerful drug carrier that can penetrate biological barriers such as the skin, the membranes, and the blood-brain-barrier. In presence of DMSO, ICG in tissue shows the excitation blue shift. However, NIRF imaging of microenvironment dependent changes of ICG has been challenging for the following reasons. First, the Stoke's shift of ICG is too small to separate the excitation and emission spectra easily. Second, the solvatochromic shift of ICG is too small to be detected by conventional NIRF techniques. Last but not least, the multiple scattering in tissue degrades not only the spatial information but also the spectral contents by the red-shift. We developed a wavelength-swept laser-based NIRF system that can resolve the excitation shift of ICG in tissue such that DMSO can be indirectly visualized. We plan to conduct an in-vivo lymph-node drug-delivery study in a mouse model to show feasibility of the indirect imaging of the drug-carrier with the wavelength-swept-laser based NIRF system.
Integrating occupancy models and structural equation models to understand species occurrence
Joseph, Maxwell B.; Preston, Daniel L.; Johnson, Pieter T. J.
2016-01-01
Understanding the drivers of species occurrence is a fundamental goal in basic and applied ecology. Occupancy models have emerged as a popular approach for inferring species occurrence because they account for problems associated with imperfect detection in field surveys. Current models, however, are limited because they assume covariates are independent (i.e., indirect effects do not occur). Here, we combined structural equation and occupancy models to investigate complex influences on species occurrence while accounting for imperfect detection. These two methods are inherently compatible because they both provide means to make inference on latent or unobserved quantities based on observed data. Our models evaluated the direct and indirect roles of cattle grazing, water chemistry, vegetation, nonnative fishes, and pond permanence on the occurrence of six pond-breeding amphibians, two of which are threatened: the California tiger salamander (Ambystoma californiense), and the California red-legged frog (Rana draytonii). While cattle had strong effects on pond vegetation and water chemistry, their overall effects on amphibian occurrence were small compared to the consistently negative effects of nonnative fish. Fish strongly reduced occurrence probabilities for four of five native amphibians, including both species of conservation concern. These results could help to identify drivers of amphibian declines and to prioritize strategies for amphibian conservation. More generally, this approach facilitates a more mechanistic representation of ideas about the causes of species distributions in space and time. As shown here, occupancy modeling and structural equation modeling are readily combined, and bring rich sets of techniques that may provide unique theoretical and applied insights into basic ecological questions. PMID:27197402
Hilderink, Janneke; Otto, Cees; Slump, Cees; Lenferink, Aufried; Engelse, Marten; van Blitterswijk, Clemens; de Koning, Eelco; Karperien, Marcel; van Apeldoorn, Aart
2013-01-01
Intrahepatic transplantation of donor islets of Langerhans is a promising therapy for patients with type 1 diabetes. It is of critical importance to accurately monitor islet quality before transplantation, which is currently done by standard histological methods that are performed off-line and require extensive sample preparation. As an alternative, we propose Raman spectroscopy which is a non-destructive and label-free technique that allows continuous real-time monitoring of the tissue to study biological changes as they occur. By performing Raman spectroscopic measurements on purified insulin and glucagon, we showed that the 520 cm-1 band assigned to disulfide bridges in insulin, and the 1552 cm-1 band assigned to tryptophan in glucagon are mutually exclusive and could therefore be used as indirect markers for the label-free distinction between both hormones. High-resolution hyperspectral Raman imaging for these bands showed the distribution of disulfide bridges and tryptophan at sub-micrometer scale, which correlated with the location of insulin and glucagon as revealed by conventional immunohistochemistry. As a measure for this correlation, quantitative analysis was performed comparing the Raman images with the fluorescence images, resulting in Dice coefficients (ranging between 0 and 1) of 0.36 for insulin and 0.19 for glucagon. Although the use of separate microscope systems with different spatial resolution and the use of indirect Raman markers cause some image mismatch, our findings indicate that Raman bands for disulfide bridges and tryptophan can be used as distinctive markers for the label-free detection of insulin and glucagon in human islets of Langerhans. PMID:24167603
[Study on serological cross-reactivity of six pathogenic phleboviruses].
Wu, Wei; Zhang, Shuo; Zhang, Quan-Fu; Li, Chuan; Liang, Mi-Fang; Li, De-Xin
2014-07-01
This article aimed to study the antigenicity of nucleocapsid proteins (NPs) in six pathogenic phleboviruses and to provide theoretical evidence for the development of serological diagnostic reagents. NPs of six pathogenic phleboviruses were expressed and purified using a prokaryotic expression system and rabbits were immunized with individual recombinant NPs. Cross-reactions among NPs and rabbit sera were determined by both indirect ELISA and Western blotting analyses, and the sera titer was determined by indirect ELISA. Furthermore, sera from SFTS patients were also detected by each recombinant NP as a coating antigen using indirect ELISA. The cross-reactions and the sera titer were subsequently determined. Both the concentration and purity of recombinant NPs of six pathogenic phleboviruses met the standards for immunization and detection. The results of indirect ELISA and Western blotting showed that each anti-phlebovirus NP rabbit immune serum had potential serological cross-reactivity with the other five virus NP antigens. Furthermore, the sera from SFTS patients also had cross-reactivity with the other five NP antigens to a certain extent. Our preliminary study evaluated the antigenicity and immune reactivity of six pathogenic phleboviruses NPs and laid the foundation for the development of diagnostic reagents.
Indirect Competitive Enzyme-Linked Immunosorbent Assay (ELISA).
Kohl, Thomas O; Ascoli, Carl A
2017-07-05
The indirect competitive ELISA (indirect cELISA) pits plate-immobilized antigen against antigens in solution for binding to antigen-specific antibody. The antigens in solution are in the test sample and are first incubated with antigen-specific antibody. These antibody-antigen complexes are then added to microtiter plates whose wells have been coated with purified antigen. The wells are washed to remove unbound antigen-antibody complexes and free antigen. A reporter-labeled secondary antibody is then added followed by the addition of substrate. Substrate hydrolysis yields a signal that is inversely proportional to antigen concentration within the sample. This is because when antigen concentration is high in the test sample, most of the antibody is bound before adding the solution to the plate. Most of the antibody remains in solution (as complexes) and is thus washed away before the addition of the reporter-labeled secondary antibody and substrate. Thus, the higher the antigen concentration in the test sample, the weaker the resultant signal in the detection step. The indirect cELISA is often used for competitive detection and quantification of antibodies against viral diseases in biological samples. © 2017 Cold Spring Harbor Laboratory Press.
Kent, Dorothea Stark; Remer, Thomas; Blumenthal, Caron; Hunt, Sharon; Simonds, Sharon; Egert, Sarah; Gaskin, Kevin J
2018-05-01
The 'gold standard' test for the indirect determination of pancreatic function status in infants with cystic fibrosis (CF), the 72-hour fecal fat excretion test, is likely to become obsolete in the near future. Alternative indirect pancreatic function tests with sufficient sensitivity and specificity to determine pancreatic phenotype need further evaluation in CF infants. Evaluation of the clinical utility of both the noninvasive, nonradioactive C-mixed triglyceride (MTG) breath test and fecal elastase-1 (FE1) in comparison with the 72-hour fecal fat assessment in infants with CF. C-MTG breath test and the monoclonal and polyclonal FE1 assessment in stool was compared with the 72-hour fecal fat assessment in 24 infants with CF. Oral pancreatic enzyme substitution (PERT; if already commenced) was stopped before the tests. Sensitivity rates between 82% and 100% for CF patients with pancreatic insufficiency assessed by both the C-MTG breath test and the FE1 tests proved to be high and promising. The C-MTG breath test (31%-38%) as well as both FE1 tests assessed by the monoclonal (46%-54%) and the polyclonal (45%) ELISA kits, however, showed unacceptably low-sensitivity rates for the detection of pancreatic-sufficient CF patients in the present study. The C-MTG breath test with nondispersive infrared spectroscopy (NDIRS) technique, as well as both FE1 tests, are not alternatives to the fecal fat balance test for the evaluation of pancreatic function in CF infants during the first year of life.
Direct Detection of The Lyman Continuum of Star-forming Galaxies at z~3
NASA Astrophysics Data System (ADS)
Vasei, Kaveh; Siana, Brian; Shapley, Alice; Alavi, Anahita; Rafelski, Marc
2018-01-01
Star-forming galaxies are widely believed to be responsible for the reionization of the Universe and much of the ionizing background at z>3. Therefore, there has been much interest in quantifying the escape fraction of the Lyman continuum (LyC) radiation of the star-forming galaxies. Yet direct detection of LyC has proven to be exceptionally challenging. Despite numerous efforts only 7 galaxies at z<2 (all with escape fractions less than 0.04) and 3 galaxies at z>2 have been robustly confirmed as LyC leakers. To avoid these challenges many studies use indirect methods to infer the LyC escape fraction. We tested these indirect methods by attempting to detect escaping LyC with a 10-orbit Hubble near-UV (F275W) image that is just below the Lyman limit at the redshift of the Cosmic Horseshoe (a lensed galaxy at z=2.4). We concluded that the measured escape fraction is lower, by more than a factor of five, than the expected escape fraction based on the indirect methods. This emphasizes that indirect determinations should only be interpreted as upper-limits. We also investigated the deepest near-UV Hubble images of the SSA22 field to detect LyC leakage from a large sample of candidate star-forming galaxies at z~3.1, whose redshift was obtained by deep Keck/LRIS spectroscopy and for which Keck narrow-band imaging was showing possible LyC leakage. The high spatial resolution of Hubble images is crucial to confirm our detections are clean from foreground contaminating galaxies, and also to ascertain the escape fraction of our final candidates. We identify five clean LyC emitting star-forming galaxies. The follow up investigation of these galaxies will significantly increase our knowledge of the LyC escape fraction and the mechanisms allowing for LyC escape.
Smartphone Fundus Photography.
Nazari Khanamiri, Hossein; Nakatsuka, Austin; El-Annan, Jaafar
2017-07-06
Smartphone fundus photography is a simple technique to obtain ocular fundus pictures using a smartphone camera and a conventional handheld indirect ophthalmoscopy lens. This technique is indispensable when picture documentation of optic nerve, retina, and retinal vessels is necessary but a fundus camera is not available. The main advantage of this technique is the widespread availability of smartphones that allows documentation of macula and optic nerve changes in many settings that was not previously possible. Following the well-defined steps detailed here, such as proper alignment of the phone camera, handheld lens, and the patient's pupil, is the key for obtaining a clear retina picture with no interfering light reflections and aberrations. In this paper, the optical principles of indirect ophthalmoscopy and fundus photography will be reviewed first. Then, the step-by-step method to record a good quality retinal image using a smartphone will be explained.
Enhanced Indirect Somatic Embryogenesis of Date Palm Using Low Levels of Seawater.
Taha, Rania A
2017-01-01
Date palm tolerates salinity, drought, and high temperatures. Arid and semiarid zones, especially the Middle East region, need a huge number of date palms for cultivation. To meet this demand, tissue culture techniques have great potential for mass production of plantlets, especially using the indirect embryogenesis technique; any improvement of these techniques is a worthy objective. Low levels of salinity can enhance growth and development of tolerant plants. A low level of seawater, a natural source of salinity, reduces the time required for micropropagation processes of date palm cv. Malkaby when added to MS medium. Medium containing seawater at 500 ppm total dissolved solid (TDS) (12.2 mL/L) improves callus proliferation, whereas 1500 ppm (36.59 mL/L) enhances plant regeneration including multiplication of secondary embryos, embryo germination, and rooting.
Enzyme immunoassay for the detection of porcine gelatine in edible bird's nests.
Tukiran, Nur Azira; Ismail, Amin; Mustafa, Shuhaimi; Hamid, Muhajir
2015-01-01
Porcine gelatine is a common adulterant found in edible bird's nests (EBNs) used to increase the net weight prior to sale. This study aimed to develop indirect enzyme-linked immunosorbent assays (ELISAs) for porcine gelatine adulteration using anti-peptide polyclonal antibodies. Three indirect ELISAs were developed (PAB1, 2 and 3), which had limits of detection (LODs) of 0.12, 0.10 and 0.11 µg g(-1), respectively. When applied to standard solutions of porcine gelatine, the inter- and intra-assays showed coefficients of variation (CVs) less than 20% and were able to detect at least 0.5 ng µg(-1) (0.05%) porcine gelatine in spiked samples. The proposed ELISA offers attractions for quality control in the EBN industry.
Hattori, Toshiaki; Anraku, Nobuhiro; Kato, Ryo
2010-02-01
Five chitosan oligosaccharides were separated in acidic aqueous solution by capillary electrophoresis (CE) with indirect photometric detection using a positively coated capillary. Electrophoretic mobility of the chitooligosaccharides (COSs) depended on the number of monomer units in acidic aqueous solution, similar to other polyelectrolyte oligomers. The separation was developed in nitric acid aqueous solution at pH 3.0 with 1 mM Crystal Violet, using a capillary positively coated with N-trimethoxypropyl-N,N,N-trimethylammonium chloride. The limit of the detection for chitooligosaccharides with two to six saccharide chains was less than 5 microM. CE determination of an enzymatically hydrolyzed COS agreed with results from HPLC. 2009 Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Different measurement techniques for aerosol characterization and quantification either directly or indirectly measure different aerosol properties (i.e. count, mass, speciation, etc.). Comparisons and combinations of multiple measurement techniques sampling the same aerosol can provide insight into...
Remote sensing strategic exploration of large or superlarge gold ore deposits
NASA Astrophysics Data System (ADS)
Yan, Shouxun; Liu, Qingsheng; Wang, Hongmei; Wang, Zhigang; Liu, Suhong
1998-08-01
To prospect large or superlarge gold ore deposits, blending of remote sensing techniques and modern metallogenitic theories is one of the effective measures. The theory of metallogeny plays a director role before and during remote sensing technique applications. The remote sensing data with different platforms and different resolutions can be respectively applied to detect direct or indirect metallogenic information, and to identify the ore-controlling structure, especially, the ore-controlling structural assemblage, which, conversely, usually are the new conditions to study and to modify the metallogenic model, and to further develop the exploration model of large or superlarge ore deposits. Guidance by an academic idea of 'adjustment structure' which is the conceptual model of transverse structure, an obscured ore- controlling transverse structure has been identified on the refined TM imagery in the Hadamengou gold ore deposit, Setai Hyperspectral Geological Remote Sensing Testing Site (SHGRSTS), Wulashan mountains, Inner Mongolia, China. Meanwhile, The MAIS data has been applied to quickly identify the auriferous alteration rocks with Correspondence Analysis method and Spectral Angle Mapping (SAM) technique. The theoretical system and technical method of remote sensing strategic exploration of large or superlarge gold ore deposits have been demonstrated by the practices in the SHGRSTS.
Krishnamurthy, Krish; Hari, Natarajan
2017-09-15
The recently published CRAFT (complete reduction to amplitude frequency table) technique converts the raw FID data (i.e., time domain data) into a table of frequencies, amplitudes, decay rate constants, and phases. It offers an alternate approach to decimate time-domain data, with minimal preprocessing step. It has been shown that application of CRAFT technique to process the t 1 dimension of the 2D data significantly improved the detectable resolution by its ability to analyze without the use of ubiquitous apodization of extensively zero-filled data. It was noted earlier that CRAFT did not resolve sinusoids that were not already resolvable in time-domain (i.e., t 1 max dependent resolution). We present a combined NUS-IST-CRAFT approach wherein the NUS acquisition technique (sparse sampling technique) increases the intrinsic resolution in time-domain (by increasing t 1 max), IST fills the gap in the sparse sampling, and CRAFT processing extracts the information without loss due to any severe apodization. NUS and CRAFT are thus complementary techniques to improve intrinsic and usable resolution. We show that significant improvement can be achieved with this combination over conventional NUS-IST processing. With reasonable sensitivity, the models can be extended to significantly higher t 1 max to generate an indirect-DEPT spectrum that rivals the direct observe counterpart. Copyright © 2017 John Wiley & Sons, Ltd.
Gornowicz-Porowska, Justyna; Seraszek-Jaros, Agnieszka; Bowszyc-Dmochowska, Monika; Kaczmarek, Elżbieta; Pietkiewicz, Paweł; Bartkiewicz, Paweł; Dmochowski, Marian
2017-02-01
Pemphigus and bullous pemphigoid (BP) are identified by autoantibodies (abs) against desmoglein 1, 3 (DSG1/3) and BP180/BP230, respectively. A novel mosaic to indirect immunofluorescence (IIF) using purified BP180 recombinant proteins spotted on slide and transfected cells expressing BP230, DSG1, DSG3 is available. The commercial (IgG detection) and modified (IgG4 detection) mosaic for indirect immunofluorescence (IIFc - IIF commercial, IIFm - IIF modified) and IgG ELISAs were evaluated in pemphigus and bullous pemphigoid (BP) molecular diagnostics. To compare diagnostic accuracy of commercial (IgG detection) and modified (IgG4 detection) mosaic IIF assay and to examine the diagnostic value of ELISAs in relation to mosaic IIF in routine laboratory diagnostics of pemphigus and BP. Sera from 37 BP and 19 pemphigus patients were studied. Associations between tests were assessed using Fisher's exact test. There are associations between the positive/negative samples detected by IIFc with desmoglein1 (DSG1)/desmoglein3 (DSG3)/BP230 transfected cells and ELISAs and no association between anti-BP180 IgG detection by IIFc and ELISA. IIFm with DSG1 and DSG3 showed both 100% sensitivity and 100% and 78% specificity, respectively, and 100% and 83% positive predictive value in relation to IIFc. IIFm with BP230 had 87% specificity, 55% sensitivity, whereas IIFm with BP180 had a 100% sensitivity and 13% specificity in relation to IIFc. The IIFc with DSG1/DSG3/BP230 transfected cells, excluding BP180 spots, is an alternative method to ELISA in pemphigus/BP diagnostics. IgG4 antibodies, both pathogenically and diagnostically important, are inconsistently detectable with IIFm.
Mourtzoukou, Despoina; Fisher, Cyril; Thway, Khin
2015-12-01
The accurate diagnosis of soft tissue neoplasms has crucial therapeutic and prognostic importance. There is frequent morphologic overlap between entities, and ancillary modalities are used in the vast majority of diagnoses. Immunohistochemistry is rapid and inexpensive, and in addition to the older markers that mainly detected cytoplasmic proteins, antibodies can indirectly detect tumor-specific genetic and molecular abnormalities. The use of molecular diagnostic techniques is now widespread, with molecular services often integrated into routine histopathology laboratories; as their cost and turnaround times begin to parallel those for immunohistochemistry, we compared the usefulness of ancillary immunohistochemistry, molecular genetic, and molecular cytogenetic techniques in the diagnosis of soft tissue lesions. We evaluated the number and contribution of immunohistochemical tests and panels and of ancillary molecular techniques in the primary histopathologic diagnosis of 150 soft tissue lesions. Ninety of 150 cases required either only one immunohistochemical panel or minimal immunohistochemistry for diagnosis, while 39/150 required 2 to 4 panels. In 5/150, ancillary molecular tests alone (without immunohistochemistry) were diagnostically sufficient. The majority of cases required one immunohistochemical panel for diagnosis, with a smaller proportion requiring a second, and a minority requiring a third or fourth (which mainly comprised neoplasms for which the final diagnosis was uncertain). Certain neoplasms required both extensive immunohistochemistry and ancillary molecular testing, despite which the final diagnosis was inconclusive. Ancillary molecular techniques now make a significant contribution to soft tissue tumor diagnosis, being required in over one third (52/150) of cases, and were useful in confirming or excluding tumors that were not possible to conclusively diagnose with histology and immunohistochemistry. Only a small proportion of soft tissue neoplasms (16/150; all benign) did not require immunohistochemistry or ancillary molecular methods, with morphology alone being sufficient for diagnosis. © The Author(s) 2015.
A study of CR-39 plastic charged-particle detector replacement by consumer imaging sensors
NASA Astrophysics Data System (ADS)
Plaud-Ramos, K. O.; Freeman, M. S.; Wei, W.; Guardincerri, E.; Bacon, J. D.; Cowan, J.; Durham, J. M.; Huang, D.; Gao, J.; Hoffbauer, M. A.; Morley, D. J.; Morris, C. L.; Poulson, D. C.; Wang, Zhehui
2016-11-01
Consumer imaging sensors (CIS) are examined for real-time charged-particle detection and CR-39 plastic detector replacement. Removing cover glass from CIS is hard if not impossible, in particular for the latest inexpensive webcam models. We show that 10-class CIS are sensitive to MeV and higher energy protons and α-particles by using a 90Sr β-source with its cover glass in place. Indirect, real-time, high-resolution detection is also feasible when combining CIS with a ZnS:Ag phosphor screen and optics. Noise reduction in CIS is nevertheless important for the indirect approach.
A study of CR-39 plastic charged-particle detector replacement by consumer imaging sensors
Plaud-Ramos, Kenie Omar; Freeman, Matthew Stouten; Wei, Wanchun; ...
2016-08-03
Consumer imaging sensors (CIS) are examined for real-time charged-particle detection and CR-39 plastic detector replacement. Removing cover glass from CIS is hard if not impossible, in particular for the latest inexpensive webcam models. We show that $10-class CIS are sensitive to MeV and higher energy protons and α-particles by using a 90Sr β-source with its cover glass in place. Indirect, real-time, high-resolution detection is also feasible when combining CIS with a ZnS:Ag phosphor screen and optics. Furthermore, noise reduction in CIS is nevertheless important for the indirect approach.
A study of CR-39 plastic charged-particle detector replacement by consumer imaging sensors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plaud-Ramos, K. O.; Freeman, M. S.; Wei, W.
Consumer imaging sensors (CIS) are examined for real-time charged-particle detection and CR-39 plastic detector replacement. Removing cover glass from CIS is hard if not impossible, in particular for the latest inexpensive webcam models. We show that $10-class CIS are sensitive to MeV and higher energy protons and α-particles by using a {sup 90}Sr β-source with its cover glass in place. Indirect, real-time, high-resolution detection is also feasible when combining CIS with a ZnS:Ag phosphor screen and optics. Noise reduction in CIS is nevertheless important for the indirect approach.
A study of CR-39 plastic charged-particle detector replacement by consumer imaging sensors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plaud-Ramos, Kenie Omar; Freeman, Matthew Stouten; Wei, Wanchun
Consumer imaging sensors (CIS) are examined for real-time charged-particle detection and CR-39 plastic detector replacement. Removing cover glass from CIS is hard if not impossible, in particular for the latest inexpensive webcam models. We show that $10-class CIS are sensitive to MeV and higher energy protons and α-particles by using a 90Sr β-source with its cover glass in place. Indirect, real-time, high-resolution detection is also feasible when combining CIS with a ZnS:Ag phosphor screen and optics. Furthermore, noise reduction in CIS is nevertheless important for the indirect approach.
Palmer, J E; Whitlock, R H; Benson, C E
1986-07-15
Equine ehrlichial colitis (Potomac horse fever), a newly identified colitis of the horse, was first recognized in Maryland. In this report, we document occurrence of the disease in Pennsylvania, New Jersey, New York, Ohio, Idaho, and Connecticut. Enzootic areas were recognized by a characteristic pattern. Frequently there was a seasonal pattern and high prevalence of sporadic colitis in unstressed horses. The attack rate per farm generally was low. Horses on pasture, as well as those stabled, were affected. Clinical signs varied from fever and depression to severe diarrhea and laminitis. Occasionally horses developed profound ileus and severe colic. Diagnosis was based on detection of an increase or decrease in serum antibody titers to Ehrlichia risticii, using an indirect fluorescent antibody technique.
Efficient visual coding and the predictability of eye movements on natural movies.
Vig, Eleonora; Dorr, Michael; Barth, Erhardt
2009-01-01
We deal with the analysis of eye movements made on natural movies in free-viewing conditions. Saccades are detected and used to label two classes of movie patches as attended and non-attended. Machine learning techniques are then used to determine how well the two classes can be separated, i.e., how predictable saccade targets are. Although very simple saliency measures are used and then averaged to obtain just one average value per scale, the two classes can be separated with an ROC score of around 0.7, which is higher than previously reported results. Moreover, predictability is analysed for different representations to obtain indirect evidence for the likelihood of a particular representation. It is shown that the predictability correlates with the local intrinsic dimension in a movie.
Gaia and exoplanets: a revolution in the making
NASA Astrophysics Data System (ADS)
Sozzetti, Alessandro
2017-09-01
The Gaia global astrometry mission is now entering its fourth year of routine science operations. With the publication of the first data release in September 2016, it has begun to fulfil its promise for revolutionary science in countless aspects of Galactic astronomy and astrophysics. I briefly review the Gaia mission status of operations and the scenario for the upcoming intermediate data releases, focusing on important lessons learned. Then, I illustrate the Gaia exoplanet science case, and discuss how the field will be revolutionized by the power of microarcsecond (μas) astrometry that is about to be unleashed. I conclude by touching upon some of the synergy elements that will call for combination of Gaia data with other indirect and direct detection and characterization techniques, for much improved understanding of exoplanetary systems.
Rotavirus infection in wild marsupials (Didelphis marsupialis) of the Amazon region.
Linhares, A C; Pereira, J D; Nakauth, C M; Gabbay, Y B
1986-01-01
Rotavirus was detected by enzyme-linked immunosorbent assay in faecal specimens collected from two (1.35%) of 148 marsupials trapped in the Amazon jungle environment. The positive samples were both from the "common opossum", Didelphis marsupialis. No infections were found in the stools of 198 animals belonging to other mammalian species: the latter included small rodents, chiropterans and primates. Electron microscopic examination of one (MA 5928) rotavirus-positive specimen showed a large number of empty particles. However, both rotavirus strains grew when inoculated in MA 104 cells (foetal Rhesus monkey kidney cells) producing clear cytopathogenic effect; indirect immunofluorescence technique of these cells showed a typical granular cytoplasmic fluorescence. The electrophoretic profile of strain MA 5928 showed a high grade of homology with that of SA 11, but also showed minor differences.
Erythropoietin abuse and erythropoietin gene doping: detection strategies in the genomic era.
Diamanti-Kandarakis, Evanthia; Konstantinopoulos, Panagiotis A; Papailiou, Joanna; Kandarakis, Stylianos A; Andreopoulos, Anastasios; Sykiotis, Gerasimos P
2005-01-01
The administration of recombinant human erythropoietin (rhEPO) increases the maximum oxygen consumption capacity, and is therefore abused as a doping method in endurance sports. The detection of erythropoietin (EPO) abuse is based on direct pharmacological and indirect haematological approaches, both of which have several limitations. In addition, current detection methods cannot cope with the emerging doping strategies of EPO mimicry, analogues and gene doping, and thus novel detection strategies are urgently needed. Direct detection methods for EPO misuse can be either pharmacological approaches that identify exogenous substances based on their physicochemical properties, or molecular methods that recognise EPO transgenes or gene transfer vectors. Since direct detection with molecular methods requires invasive procedures, it is not appropriate for routine screening of large numbers of athletes. In contrast, novel indirect methods based on haematological and/or molecular profiling could be better suited as screening tools, and athletes who are suspect of doping would then be submitted to direct pharmacological and molecular tests. This article reviews the current state of the EPO doping field, discusses available detection methods and their shortcomings, outlines emerging pharmaceutical and genetic technologies in EPO misuse, and proposes potential directions for the development of novel detection strategies.
NASA Astrophysics Data System (ADS)
Pramanik, Brahmananda
The dynamic response of exfoliated graphite nanoplatelet (xGnP) reinforced and carboxyl terminated butadiene nitrile (CTBN) toughened vinyl ester based nanocomposites are characterized under both dynamic tensile and compressive loading. Dynamic direct tensile tests are performed applying the reverse impact Split Hopkinson Pressure Bar (SHPB) technique. The specimen geometry for tensile test is parametrically optimized by Finite Element Analysis (FEA) using ANSYS Mechanical APDLRTM. Uniform stress distribution within the specimen gage length has been verified using high-speed digital photography. The on-specimen strain gage installation is substituted by a non-contact Laser Occlusion Expansion Gage (LOEG) technique for infinitesimal dynamic tensile strain measurements. Due to very low transmitted pulse signal, an alternative approach based on incident pulse is applied for obtaining the stress-time history. Indirect tensile tests are also performed combining the conventional SHPB technique with Brazilian disk test method for evaluating cylindrical disk specimens. The cylindrical disk specimen is held snugly in between two concave end fixtures attached to the incident and transmission bars. Indirect tensile stress is estimated from the SHPB pulses, and diametrical transverse tensile strain is measured using LOEG. Failure diagnosis using high-speed digital photography validates the viability of utilizing this indirect test method for characterizing the tensile properties of the candidate vinyl ester based nanocomposite system. Also, quasi-static indirect tensile response agrees with previous investigations conducted using the traditional dog-bone specimen in quasi-static direct tensile tests. Investigation of both quasi-static and dynamic indirect tensile test responses show the strain rate effect on the tensile strength and energy absorbing capacity of the candidate materials. Finally, the conventional compressive SHPB tests are performed. It is observed that both strength and energy absorbing capacity of these candidate material systems are distinctively less under dynamic tension than under compressive loading. Nano-reinforcement appears to marginally improve these properties for pure vinyl ester under dynamic tension, although it is found to be detrimental under dynamic compression.
NASA Astrophysics Data System (ADS)
Soto-Pinto, C. A.; Arellano-Baeza, A. A.; Ouzounov, D. P.
2012-12-01
Among a variety of processes involved in seismic activity, the principal process is the accumulation and relaxation of stress in the crust, which takes place at the depth of tens of kilometers. While the Earth's surface bears at most the indirect sings of the accumulation and relaxation of the crust stress, it has long been understood that there is a strong correspondence between the structure of the underlying crust and the landscape. We assume the structure of the lineaments reflects an internal structure of the Earth's crust, and the variation of the lineament number and arrangement reflects the changes in the stress patterns related to the seismic activity. Contrary to the existing assumptions that lineament structure changes only at the geological timescale, we have found that the much faster seismic activity strongly affects the system of lineaments extracted from the high-resolution multispectral satellite images. Previous studies have shown that accumulation of the stress in the crust previous to a strong earthquake is directly related to the number increment and preferential orientation of lineament configuration present in the satellite images of epicenter zones. This effect increases with the earthquake magnitude and can be observed approximately since one month before. To study in details this effect we have developed a software based on a series of algorithms for automatic detection of lineaments. It was found that the Hough transform implemented after the application of discontinuity detection mechanisms like Canny edge detector or directional filters is the most robust technique for detection and characterization of changes in the lineament patterns related to strong earthquakes, which can be used as a robust long-term precursor of earthquakes indicating regions of strong stress accumulation.
Yang, Qi; Duan, Jiangang; Fan, Zhaoyang; Qu, Xiaofeng; Xie, Yibin; Nguyen, Christopher; Du, Xiangying; Bi, Xiaoming; Li, Kuncheng; Ji, Xunming; Li, Debiao
2015-01-01
Background and Purpose Early diagnosis of cerebral venous and sinus thrombosis (CVT) is currently a major clinical challenge. We proposed a novel MR black-blood thrombus imaging technique(MRBTI) for detection and quantification of CVT. Methods MRBTI was performed on 23 patients with proven CVT and 24 patients with negative CVT confirmed by conventional imaging techniques. Patients were divided into two groups based on the duration of clinical onset: ≤ 7 days (group 1); between 7 and 30 days (group 2). Signal-to-noise ratio (SNR) was calculated for the detected thrombus and contrast-to-noise ratio (CNR) was measured between thrombus and lumen, and also between thrombus and brain tisssue. The feasibility of using MRBTI for thrombus volume measurement was explored and total thrombus volume was calculated for each patient. Results In 23 patients with proven CVT, MRBTI correctly identified 113 out of 116 segments with a sensitivity of 97.4%. Thrombus SNR was 153±57 and 261±95 for group 1(n=10) and group 2(n=13), respectively(P<0.01). Thrombus to lumen CNR was 149±57 and 256±94 for group 1 and group 2. Thrombus to brain tissue CNR was 41±36 and 120±63 (P<0.01), respectively. Quantification of thrombus volume was successfully conducted in all patients with CVT, and mean volume of thrombus was 10.5±6.9cc. Conclusions The current findings support that with effectively suppressed blood signal, MRBTI allows selective visualization of thrombus as opposed to indirect detection of venous flow perturbation and can be used as a promising first line diagnostic imaging tool. PMID:26670082
Frébet, Elise; Abraham, Julie; Geneviève, Franck; Lepelley, Pascale; Daliphard, Sylvie; Bardet, Valérie; Amsellem, Sophie; Guy, Julien; Mullier, Francois; Durrieu, Francoise; Venon, Marie-Dominique; Leleu, Xavier; Jaccard, Arnaud; Faucher, Jean-Luc; Béné, Marie C; Feuillard, Jean
2011-05-01
Flow cytometry is the sole available technique for quantification of tumor plasma-cells in plasma-cell disorders, but so far, no consensus technique has been proposed. Here, we report on a standardized, simple, robust five color flow cytometry protocol developed to characterize and quantify bone marrow tumor plasma-cells, validated in a multicenter manner. CD36 was used to exclude red blood cell debris and erythroblasts, CD38 and CD138 to detect plasma-cells, immunoglobulin light chains, CD45, CD56, CD19, and CD117 + CD34 to simultaneously characterize abnormal plasma-cells and quantify bone marrow precursors. This approach was applied in nine centers to 229 cases, including 25 controls. Tumor plasma-cells were detected in 96.8% of cases, all exhibiting an immunoglobulin peak over 1g/L. Calculation of a plasma-cells/precursors (PC/P) ratio allowed quantification of the plasma-cell burden independently from bone marrow hemodilution. The PC/P ratio yielded the best results in terms of sensitivity (81%) and specificity (84%) for differential diagnosis between MGUS and myeloma, when compared with other criteria. Combination of both the PC/P ratio and percentage of abnormal plasma-cells allowed the best differential diagnosis, but these criteria were discordant in 25% cases. Indirect calculation of CD19 negative PC/R ratio gave the best results in terms of sensitivity (87%). This standardized multiparameter flow cytometric approach allows for the detection and quantification of bone marrow tumor plasma-cell infiltration in nearly all cases of MGUS and myeloma, independently of debris and hemodilution. This approach may also prove useful for the detection of minimal residual disease. Copyright © 2010 International Clinical Cytometry Society.
Tankaew, Pallop; Singh-La, Thawatchai; Titaram, Chatchote; Punyapornwittaya, Veerasak; Vongchan, Preeyanat; Sawada, Takuo; Sthitmatee, Nattawooti
2017-03-01
Pasteurella multocida causes haemorrhagic septicemia in livestock and wild animals, including elephants. The disease has been reported in Asian elephants in India and Sri Lanka, but to date there have been no reported cases in Thailand. ELISA or indirect hemagglutination assays (IHA) have been demonstrated to be able to detect the antibody against the disease in cattle, but no data are available for elephants. The present study reports a novel in-house indirect ELISA for antibody detection of haemorrhagic septicemia in Asian elephants, and evaluates the sensitivity and specificity of the method using a Bayesian approach. The characteristics of ELISA and IHA were analyzed using a one population Bayesian model assuming conditional dependence between these two diagnostic tests. The IHA was performed as recommended by the World Organization for Animal Health (OIE) manual for haemorrhagic septicemia. An in-house indirect ELISA was developed with a heat extract antigen of P. multocida strain M-1404 (serovar B:2) as a coating antigen and rabbit anti-immunoglobulin G conjugated with horseradish peroxidase (eIgG-HRP). The checkerboard titration method was done using elephant sera immunized with P. multocida bacterin and negative sera from colostrum-deprived elephant calves. The concentrations of heat extract antigen (160μg/ml), sample serum (1:100), and eIgG-HRP (1:1000) were optimal for the assay. The calculated cut-off value was 0.103. Of the elephant sera, 50.59% (43/85) were considered seropositive by ELISA. The sensitivity of the ELISA test was higher than that of the IHA test [median=86.5%, 95% posterior probability interval (PPI)=52.5-98.9%] while the specificity was lower (median=54.1%, PPI=43.6-64.7%). The median sensitivity and specificity of IHA were 80.5% (PPI=43.8-98.0%) and 78.4% (PPI=69.0-87.0%), respectively. These findings suggest that our in-house indirect ELISA can be used as a tool to detect the antibody against haemorrhagic septicemia in Asian elephants. Copyright © 2017 Elsevier B.V. All rights reserved.
DEVELOPMENT OF AN ULTRASONIC INDIRECT BLOOD PRESSURE SENSING TECHNIQUE FOR AEROSPACE APPLICATION,
with arterial opening motion, comparing systolic and diastolic pressures thus obtained to those acquired by auscultation and recording Korotkoff sounds...level airborne noise environments where auscultation techniques were not usable. Tests made with patients in shock showed performance of the
Detection of Toxoplasma gondii in the milk of naturally infected goats in the Northeast of Brazil.
Bezerra, M J G; Kim, P C P; Moraes, É P B X; Sá, S G; Albuquerque, P P F; Silva, J G; Alves, B H L S; Mota, R A
2015-08-01
The aim of the present study was to detect the genomic DNA of Toxoplasma gondii in milk samples from naturally infected goats in the state of Pernambuco, (Brazil). In total, 248 blood serum samples were collected and processed from lactating goats and then submitted to a search for antibodies to T. gondii through the indirect immunofluorescence reaction. Samples with a score of 64 or more were considered positive. In total, 248 milk samples were collected and processed from the same group of goats in order to study the DNA of T. gondii using the polymerase chain reaction (PCR) technique. In the serum samples, 56/248 (22.58%) of the animals were positive, whereas the DNA of the parasite was detected in 15/248 (6.05%) of the milk samples. Five of these 15 samples were animals who were also positive in the serology. This study reports the first occurrence of the elimination of T. gondii from the milk of naturally infected goats in the north-east of Brazil. It is suggested that the consumption of in natura goat milk may constitute a potential risk to the health of milk consumers in this region. © 2013 Blackwell Verlag GmbH.
NASA Astrophysics Data System (ADS)
Bae, Kyu Jung; Baer, Howard; Serce, Hasan
2017-06-01
Under the expectation that nature is natural, we extend the Standard Model to include SUSY to stabilize the electroweak sector and PQ symmetry to stabilize the QCD sector. Then natural SUSY arises from a Kim-Nilles solution to the SUSY μ problem which allows for a little hierarchy where μ~ fa2/MP~ 100-300 GeV while the SUSY particle mass scale mSUSY~ 1-10 TeV gg μ. Dark matter then consists of two particles: a higgsino-like WIMP and a SUSY DFSZ axion. The range of allowed axion mass values ma depends on the mixed axion-higgsino relic density. The range of ma is actually restricted in this case by limits on WIMPs from direct and indirect detection experiments. We plot the expected axion detection rate at microwave cavity experiments. The axion-photon-photon coupling is severely diminished by charged higgsino contributions to the anomalous coupling. In this case, the axion may retreat, at least temporarily, back into the regime of near invisibility. From our results, we urge new ideas for techniques which probe both deeper and more broadly into axion coupling versus axion mass parameter space.
Wongtangprasert, Tossapon; Natakuathung, Wirongrong; Pimpitak, Umaporn; Buakeaw, Anumart; Palaga, Tanapat; Komolpis, Kittinan; Khongchareonporn, Nanthika
2014-01-01
A novel monoclonal antibody (MAb) against oxytetracycline (OTC) was generated and characterized. The MAb was used in the development of an enzyme-linked immunosorbant assay (ELISA)-based detection system. An OTC-bovine serum albumin (BSA) conjugate was prepared and used in the immunization of mice. A conventional somatic cell fusion technique was used to generate MAb-secreting hybridomas denoted 2-4F, 7-3G, and 11-11A. An indirect competitive ELISA (icELISA) was applied to measure the sensitivity and specificity of each MAb in terms of its 50% inhibitory concentration (IC50) and percentage of cross-reactivity, respectively. MAb 2-4F exhibited the highest sensitivity, with an IC50 of 7.01 ng/ml. This MAb showed strong cross-reactivity to rolitetracycline, but no cross-reactivity to other unrelated antibiotics. When MAb 2-4F was used to detect OTC from shrimp samples, the recoveries were in the range of 82%–118% for an intra-assay and 96%–113% for an inter-assay. The coefficients of variation of the assays were 3.9%–13.9% and 5.5%–14.9%, respectively. PMID:24510709
Novel highly-performing immunosensor-based strategy for ochratoxin A detection in wine samples.
Prieto-Simón, Beatriz; Campàs, Mònica; Marty, Jean-Louis; Noguer, Thierry
2008-02-28
The increasing concern about ochratoxin A (OTA) contamination of different food and feedstuffs demands high-performing detection techniques for quality assessment. Two indirect competitive enzyme-linked immunosorbent assay (ELISA) strategies were investigated for the development of OTA electrochemical immunosensors based on different OTA immobilisation procedures. Immunosensors based on avidin/biotin-OTA showed enhanced performance characteristics compared to those based on the adsorption of bovine serum albumin (BSA)-OTA conjugate. Performance of polyclonal (PAb) and monoclonal (MAb) antibodies against OTA was compared, showing at least one-order of magnitude lower IC(50) values when working with MAb. Alkaline phosphatase (ALP)- and horseradish peroxidase (HRP)-labelled secondary antibodies were evaluated. Both conjugates led to similar results when working with OTA standard solutions in buffer. However, whereas electroactive interferences present in spiked wine samples did not affect HRP-labelled immunosensors (4% slope deviation), they were likely oxidised at 0.225 V versus Ag/AgCl, the working potential for ALP-labelled immunosensors (25% slope deviation). Considering 80% of antibody binding as the limit of detection, values of 0.7 and 0.3 ng/mL for HRP- and ALP-labelled immunosensors respectively, validate these immunosensors as useful screening tools to assess OTA levels in wine.
Review of current neutron detection systems for emergency response
Mukhopadhyay, Sanjoy; Maurer, Richard; Guss, Paul; ...
2014-09-05
Neutron detectors are utilized in a myriad of applications—from safeguarding special nuclear materials (SNM) to determining lattice spacing in soft materials. The transformational changes taking place in neutron detection and imaging techniques in the last few years are largely being driven by the global shortage of helium-3 ( 3He). This article reviews the status of neutron sensors used specifically for SNM detection in radiological emergency response. These neutron detectors must be highly efficient, be rugged, have fast electronics to measure neutron multiplicity, and be capable of measuring direction of the neutron sources and possibly image them with high spatial resolution.more » Neutron detection is an indirect physical process: neutrons react with nuclei in materials to initiate the release of one or more charged particles that produce electric signals that can be processed by the detection system. Therefore, neutron detection requires conversion materials as active elements of the detection system; these materials may include boron-10 ( 10B), lithium-6 ( 6Li), and gadollinium-157 ( 157Gd), to name a few, but the number of materials available for neutron detection is limited. However, in recent years, pulse-shape-discriminating plastic scintillators, scintillators made of helium-4 ( 4He) under high pressure, pillar and trench semiconductor diodes, and exotic semiconductor neutron detectors made from uranium oxide and other materials have widely expanded the parameter space in neutron detection methodology. In this article we will pay special attention to semiconductor-based neutron sensors. Finally, modern microfabricated nanotubes covered inside with neutron converter materials and with very high aspect ratios for better charge transport will be discussed.« less
Review of current neutron detection systems for emergency response
NASA Astrophysics Data System (ADS)
Mukhopadhyay, Sanjoy; Maurer, Richard; Guss, Paul; Kruschwitz, Craig
2014-09-01
Neutron detectors are used in a myriad of applications—from safeguarding special nuclear materials (SNM) to determining lattice spacing in soft materials. The transformational changes taking place in neutron detection and imaging techniques in the last few years are largely being driven by the global shortage of helium-3 (3He). This article reviews the status of neutron sensors used specifically for SNM detection in radiological emergency response. These neutron detectors must be highly efficient, be rugged, have fast electronics to measure neutron multiplicity, and be capable of measuring direction of the neutron sources and possibly image them with high spatial resolution. Neutron detection is an indirect physical process: neutrons react with nuclei in materials to initiate the release of one or more charged particles that produce electric signals that can be processed by the detection system. Therefore, neutron detection requires conversion materials as active elements of the detection system; these materials may include boron-10 (10B), lithium-6 (6Li), and gadollinium-157 (157Gd), to name a few, but the number of materials available for neutron detection is limited. However, in recent years, pulse-shape-discriminating plastic scintillators, scintillators made of helium-4 (4He) under high pressure, pillar and trench semiconductor diodes, and exotic semiconductor neutron detectors made from uranium oxide and other materials have widely expanded the parameter space in neutron detection methodology. In this article we will pay special attention to semiconductor-based neutron sensors. Modern microfabricated nanotubes covered inside with neutron converter materials and with very high aspect ratios for better charge transport will be discussed.
NASA Astrophysics Data System (ADS)
Franςois, A.; Boehm, J.; Oh, S. Y.; Kok, T.; Monro, T. M.
2011-06-01
The management of threats such as pandemics and explosives, and of health and the environment requires the rapid deployment of highly sensitive detection tools. Sensors based on Surface Plasmon Resonance (SPR) allow rapid, labelfree, highly sensitive detection, and indeed this phenomenon underpins the only label-free optical biosensing technology that is available commercially. In these sensors, the existence of surface plasmons is inferred indirectly from absorption features that correspond to the coupling of light to the surface plasmon. Although SPR is not intrinsically a radiative process, under certain conditions the surface plasmon can itself couple to the local photon states, and emit light as first described byKretschmann. Here we show that by collecting and characterising this re-emitted light, it is possible to realise new SPR sensing architectures that are more compact, versatile and robust than existing approaches. This approach addresses existing practical limitations associated with current SPR technologies, including bulk, cost and calibration. It is applicable to a range of SPR geometries, including optical fibres, planar waveguides and prism configurations, and is in principle capable of detecting multiple analytes simultaneously. Moreover, this technique allows to combine SPR sensing and fluorescence sensing into a single platform which has never been demonstrated before and consequently use these two methods for a more reliable diagnostic. As an example, this approach has been used to demonstrate the rapid detection of the seasonal influenza virus.
Local viscoelastic response of direct and indirect dental restorative composites measured by AFM.
Grattarola, Laura; Derchi, Giacomo; Diaspro, Alberto; Gambaro, Carla; Salerno, Marco
2018-06-08
We investigated the viscoelastic response of direct and indirect dental restorative composites by the novel technique of AM-FM atomic force microscopy. We selected four composites for direct restorations (Adonis, Optifil, EPH, CME) and three composites for indirect restorations (Gradia, Estenia, Signum). Scanning electron microscopy with micro-analysis was also used to support the results. The mean storage modulus of all composites was in the range of 10.2-15.2 GPa. EPH was the stiffest (p<0.05 vs. all other composites but Adonis and Estenia), while no significant difference was observed between direct and indirect group (p≥0.05). For the loss tangent, Gradia had the highest value (~0.3), different (p<0.05) from Optifil (~0.01) and EPH (~0.04) despite the large coefficient of variation (24%), and the direct composites showed higher loss tangent (p<0.01) than the indirect composites. All composites exhibited minor contrast at the edge of fillers, showing that these are pre-polymerized, as confirmed by EDS.
Pore Size Control in Aluminium Foam by Standardizing Bubble Rise Velocity and Melt Viscosity
NASA Astrophysics Data System (ADS)
Avinash, G.; Harika, V.; Sandeepika, Ch; Gupta, N.
2018-03-01
In recent years, aluminium foams have found use in a wide range of applications. The properties of these foams, as good structural strength with light weight have made them as a promising structural material for aerospace industry. Foaming techniques (direct and indirect) are used to produce these foams. Direct foaming involves blowing of gas to create gas bubbles in the melt whereas indirect foaming technique uses blowing agents as metallic hydrides, which create hydrogen bubbles. Porosity and its distribution in foams directly affect its properties. This demands for more theoretical studies, to control such cellular structure and hence properties. In present work, we have studied the effect of gas bubble rise velocity and melt viscosity, on pore size and its distribution in aluminium foam. A 15 PPI aluminium foam, prepared using indirect foaming technique having porosity ~86 % was used for study. In order to obtain metal foam, the bubble must not escape from the melt and should get entrapped during solidification. Our calculations suggest that bubble rise velocity and melt viscosity are responsible for vertical displacement of bubble in the melt. It is observed that melt viscosity opposes bubble rise velocity and help the bubbles to stay in the melt, resulting in porous structure.
Chavaillaz, Alain; Schwaninger, Adrian; Michel, Stefan; Sauer, Juergen
2018-05-25
The present study evaluated three automation modes for improving performance in an X-ray luggage screening task. 140 participants were asked to detect the presence of prohibited items in X-ray images of cabin luggage. Twenty participants conducted this task without automatic support (control group), whereas the others worked with either indirect cues (system indicated the target presence without specifying its location), or direct cues (system pointed out the exact target location) or adaptable automation (participants could freely choose between no cue, direct and indirect cues). Furthermore, automatic support reliability was manipulated (low vs. high). The results showed a clear advantage for direct cues regarding detection performance and response time. No benefits were observed for adaptable automation. Finally, high automation reliability led to better performance and higher operator trust. The findings overall confirmed that automatic support systems for luggage screening should be designed such that they provide direct, highly reliable cues.
Evaluation of indirect impedance for measuring microbial growth in complex food matrices.
Johnson, N; Chang, Z; Bravo Almeida, C; Michel, M; Iversen, C; Callanan, M
2014-09-01
The suitability of indirect impedance to accurately measure microbial growth in real food matrices was investigated. A variety of semi-solid and liquid food products were inoculated with Bacillus cereus, Listeria monocytogenes, Staphylococcus aureus, Lactobacillus plantarum, Pseudomonas aeruginosa, Escherichia coli, Salmonella enteriditis, Candida tropicalis or Zygosaccharomyces rouxii and CO2 production was monitored using a conductimetric (Don Whitely R.A.B.I.T.) system. The majority (80%) of food and microbe combinations produced a detectable growth signal. The linearity of conductance responses in selected food products was investigated and a good correlation (R(2) ≥ 0.84) was observed between inoculum levels and times to detection. Specific growth rate estimations from the data were sufficiently accurate for predictive modeling in some cases. This initial evaluation of the suitability of indirect impedance to generate microbial growth data in complex food matrices indicates significant potential for the technology as an alternative to plating methods. Copyright © 2014 Elsevier Ltd. All rights reserved.
Kivlighan, Dennis M; Hill, Clara E; Ross, Katherine; Kline, Kathryn; Furhmann, Amy; Sauber, Elizabeth
2018-01-05
To test a sequential model of psychotherapy process and outcome, we included previous client distress, therapist psychodynamic techniques, dyadic working alliance, and current client distress. For 114 sets of eight-session segments in 40 cases of psychodynamic psychotherapy, clients completed the Outcome Questionnaire-45 and Inventory of Interpersonal Problems-32 after the first and final session, judges reliably coded one middle sessions on the Psychodynamic subscale of the Multitheoretical List of Therapeutic Interventions, and clients and therapists completed the Working Alliance Inventory after every session. Results indicated that higher use of psychodynamic techniques was associated with higher levels of the working alliance, which in turn was associated decreased client distress; and working alliance was higher later in psychotherapy. There was a significant indirect effect of psychodynamic techniques on decreases in distress mediated by the working alliance. Implications for theory, practice, and research are provided. Clinical or methodological significance of this article: Conducted a longitudinal, latent variable examination of the relationships of psychodynamic techniques and working alliance on client distress. Psychodynamic techniques have an indirect effect on decreases in client distress through the dyadic working alliance.
Indirect evidence suggests that induced sputum derives from the surfaces of the bronchial airways. To confirm this experimentally, we employed a radiolabeled aerosol bolus delivery technique that preferentially deposits aerosol in the central airways in humans. We hypothesized th...
Comparison of a direct and indirect ELISA for quantitating antisperm antibody in semen.
Lynch, D M; Howe, S E
1987-01-01
A direct and an indirect quantitative ELISA for antisperm antibody were compared using the spermatozoa and cell-free seminal fluid of 66 infertile males. The normal concentration of sperm binding immunoglobulin was less than or equal to 1.5 fg Ig per spermatozoon for the indirect seminal plasma assay and less than or equal to 1.5 fg Ig per spermatozoon by the direct assay. Of the 66 infertile males, 21% (14/66) had elevated levels of antisperm antibody in their seminal plasma and 26% (17/66) had elevated levels bound directly to their spermatozoa. The direct correlation between the results of these assays was 94%. A simple linear regression analysis between the indirect and direct measurements of antisperm antibody resulted in a correlation coefficient of r = 0.907. There was no statistically significant difference between results from the direct and indirect methods of the patients as a group. However, there was evidence of autospecificity in a small percentage of males who had elevated levels of antisperm antibody by the direct assay that was not detected by the indirect assay using pooled donor spermatozoa.
Thibodeaux, Brett A.; Panella, Amanda N.; Roehrig, John T.
2010-01-01
Diagnosis of human arboviral infections relies heavily on serological techniques such as the immunoglobulin M (IgM) antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) and the indirect IgG ELISA. Broad application of these assays is hindered by the lack of standardized positive human control sera that react with a wide variety of flaviviruses (e.g., dengue, West Nile, yellow fever, Japanese encephalitis, Saint Louis encephalitis, and Powassan viruses), or alphaviruses (e.g., Eastern equine encephalitis, Western equine encephalitis, Venezuelan equine encephalitis, and chikungunya viruses) that can cause human disease. We have created human-murine chimeric monoclonal antibodies (cMAbs) by combining the variable regions of flavivirus (6B6C-1) or alphavirus (1A4B-6) broadly cross-reactive murine MAbs (mMAbs) with the constant region of human IgG1. These cMAbs may be used as standardized reagents capable of replacing human infection-immune-positive control sera in indirect IgG ELISA for diagnosis of all human flaviviral or alphaviral infections. The IgG cMAbs secreted from plasmid-transformed Sp2/0-Ag14 cells had serological activity identical to that of the parent mMAbs, as measured by ELISA using multiple flaviviruses or alphaviruses. PMID:20739503
Thibodeaux, Brett A; Panella, Amanda N; Roehrig, John T
2010-10-01
Diagnosis of human arboviral infections relies heavily on serological techniques such as the immunoglobulin M (IgM) antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) and the indirect IgG ELISA. Broad application of these assays is hindered by the lack of standardized positive human control sera that react with a wide variety of flaviviruses (e.g., dengue, West Nile, yellow fever, Japanese encephalitis, Saint Louis encephalitis, and Powassan viruses), or alphaviruses (e.g., Eastern equine encephalitis, Western equine encephalitis, Venezuelan equine encephalitis, and chikungunya viruses) that can cause human disease. We have created human-murine chimeric monoclonal antibodies (cMAbs) by combining the variable regions of flavivirus (6B6C-1) or alphavirus (1A4B-6) broadly cross-reactive murine MAbs (mMAbs) with the constant region of human IgG1. These cMAbs may be used as standardized reagents capable of replacing human infection-immune-positive control sera in indirect IgG ELISA for diagnosis of all human flaviviral or alphaviral infections. The IgG cMAbs secreted from plasmid-transformed Sp2/0-Ag14 cells had serological activity identical to that of the parent mMAbs, as measured by ELISA using multiple flaviviruses or alphaviruses.
Application of random coherence order selection in gradient-enhanced multidimensional NMR
NASA Astrophysics Data System (ADS)
Bostock, Mark J.; Nietlispach, Daniel
2016-03-01
Development of multidimensional NMR is essential to many applications, for example in high resolution structural studies of biomolecules. Multidimensional techniques enable separation of NMR signals over several dimensions, improving signal resolution, whilst also allowing identification of new connectivities. However, these advantages come at a significant cost. The Fourier transform theorem requires acquisition of a grid of regularly spaced points to satisfy the Nyquist criterion, while frequency discrimination and acquisition of a pure phase spectrum require acquisition of both quadrature components for each time point in every indirect (non-acquisition) dimension, adding a factor of 2 N -1 to the number of free- induction decays which must be acquired, where N is the number of dimensions. Compressed sensing (CS) ℓ 1-norm minimisation in combination with non-uniform sampling (NUS) has been shown to be extremely successful in overcoming the Nyquist criterion. Previously, maximum entropy reconstruction has also been used to overcome the limitation of frequency discrimination, processing data acquired with only one quadrature component at a given time interval, known as random phase detection (RPD), allowing a factor of two reduction in the number of points for each indirect dimension (Maciejewski et al. 2011 PNAS 108 16640). However, whilst this approach can be easily applied in situations where the quadrature components are acquired as amplitude modulated data, the same principle is not easily extended to phase modulated (P-/N-type) experiments where data is acquired in the form exp (iωt) or exp (-iωt), and which make up many of the multidimensional experiments used in modern NMR. Here we demonstrate a modification of the CS ℓ 1-norm approach to allow random coherence order selection (RCS) for phase modulated experiments; we generalise the nomenclature for RCS and RPD as random quadrature detection (RQD). With this method, the power of RQD can be extended to the full suite of experiments available to modern NMR spectroscopy, allowing resolution enhancements for all indirect dimensions; alone or in combination with NUS, RQD can be used to improve experimental resolution, or shorten experiment times, of considerable benefit to the challenging applications undertaken by modern NMR.
Kolb, Klaus; Koller, Heiko; Lorenz, Ingo; Holz, Ulrich; Marx, Frank; Grützner, Paul; Kolb, Werner
2009-04-01
The complication rate of conventional plate osteosynthesis (CPO) of periprosthetic femoral fractures above total knee arthroplasties (TKA) is high. Indirect reduction techniques were introduced to reduce surgical dissection at the fracture site. Twenty-one patients (4 men and 17 women) with femoral fractures above well-fixed total knee arthroplasties were consecutively treated with the indirect reduction technique. AO/ASIF (Arbeitsgemeinschaft für Osteosynthesefragen/Association for the Study of the Problems of Internal Fixation) Type 33A fractures were included. The mean age was 78 years (range, 67-94 years). Four fractures were stabilised with bone grafts, three in combination with bone cement. Nineteen of the patients were seen at a 1-year follow-up, 15 were seen after a long-term follow-up of 9 years (range, 7-12 years). There was only one implant failure in a comminuted fracture with severe osteoporosis, no infection, and no non-union. At the 1-year follow-up malalignment of 5 degrees varus occurred in one patient. The mean range of motion of the eighteen patients was 98 degrees (range, 65-110 degrees). The mean knee society score was 74 (range, 62-84), the mean function score was 52 (range, 39-72). At the long-term follow-up, the mean range of motion of the patients was 101 degrees (range, 65-115 degrees). The mean knee society score was 77 (range, 65-88), the mean function score was 55 (range, 40-75). Our results suggest the 95 degrees condylar blade plate in the indirect reduction technique is still a good implant with good long-term results. It works best in proximal fractures when there is minimal comminution of the distal fragment in the hands of an experienced trauma surgeon. Knee function and range of motion increased less over time.
Wei, Kai; Zhang, Haiyan; Zhang, Yuewei; Xu, Jian; Jiang, Fei; Liu, Xu; Xu, Wei; Wu, Wenxue
2014-01-01
The pathogen Mycoplasma bovis (M. bovis) is a major cause of respiratory disease, mastitis, and arthritis in cattle. Screening the key immunogenic proteins and updating rapid diagnostic techniques are necessary to the prevention and control of M. bovis infection. In this study, 19 highly immunogenic proteins from M. bovis strain PD were identified using 2-dimensional gel electrophoresis, immunoblotting and MALDI-TOF/TOF MS. Of these 19 proteins, pyruvate dehydrogenase E1 component beta subunit (PDHB) showed excellent immune reactivity and repeatability. PDHB was found to be conserved in different M. bovis isolates, as indicated by Western blot analysis. On the basis of these results, a rPDHB-based indirect ELISA (iELISA) was established for the detection of serum antibodies using prokaryotically expressed recombinant PDHB protein as the coating antigen. The specificity analysis result showed that rPDHB-based iELISA did not react with other pathogens assessed in our study except M. agalactiae (which infects sheep and goats). Moreover, 358 serum samples from several disease-affected cattle feedlots were tested using this iELISA system and a commercial kit, which gave positive rates of 50.8% and 39.9%, respectively. The estimated Kappa agreement coefficient between the two methods was 0.783. Notably, 39 positive serum samples that had been missed by the commercial kit were all found to be positive by Western blot analysis. The detection rate of rPDHB-based iELISA was significantly higher than that of the commercial kit at a serum dilution ratio of 1∶5120 to 1∶10,240 (P<0.05). Taken together, these results provide important information regarding the novel immunogenic proteins of M. bovis. The established rPDHB-based iELISA may be suitable for use as a new method of antibody detection in M. bovis. PMID:24520369
Kain, Jay; Martorello, Laura; Swanson, Edward; Sego, Sandra
2011-01-01
The purpose of the randomized clinical study was to scientifically assess which intervention increases passive range of motion most effectively: the indirect tri-planar myofascial release (MFR) technique or the application of hot packs for gleno-humeral joint flexion, extension, and abduction. A total of 31 participants from a sample of convenience were randomly assigned to examine whether or not MFR was as effective in increasing range of motion as hot packs. The sample consisted of students at American International College. Students were randomly assigned to two groups: hot pack application (N=13) or MFR technique (N=18). The independent variable was the intervention, either the tri-planar MFR technique or the hot pack application. Group one received the indirect tri-planar MFR technique once for 3min. Group two received one hot pack application for 20min. The dependent variables, passive gleno-humeral shoulder range of motion in shoulder flexion, shoulder extension, and shoulder abduction, were taken pre- and post-intervention for both groups. Data was analyzed through the use of a two-way factorial design with mixed-factors ANOVA. Prior to conducting the study, inter-rater reliability was established using three testers for goniometric measures. A 2 (type of intervention: hot packs or MFR) by 2 (pre-test or post-test) mixed-factors ANOVA was calculated. Significant increases in range of motion were found for flexion, extension and abduction when comparing pre-test scores to post-test scores. The results of the ANOVA showed that for passive range of motion no differences were found for flexion, extension and abduction between the effectiveness of hot packs and MFR. For each of the dependent variables measured, MFR was shown to be as effective as hot packs in increasing range of motion, supporting the hypothesis. Since there was no significant difference between the types of intervention, both the hot pack application and the MFR technique were found to be equally effective in increasing passive range of motion of the joint in flexion, extension, and abduction of the gleno-humeral joint. The indirect tri-planar intervention could be considered more effective as an intervention in terms of time spent with a patient and the number of patients seen in a 20-min period. No equipment is required to carry out the MFR intervention, whereby using a hot pack requires the hot pack, towels, and a hydraculator unit with the use of the indirect tri-planar intervention, a therapist could treat four to five patients in the time it would take for one standard hot pack treatment of 20min, less the hands-on intervention of the therapist. Copyright © 2009 Elsevier Ltd. All rights reserved.
The use of vertical seismic profiles in seismic investigations of the earth
Balch, Alfred H.; Lee, M.W.; Miller, J.J.; Ryder, Robert T.
1982-01-01
During the past 8 years, the U.S. Geological Survey has conducted an extensive investigation on the use of vertical seismic profiles (VSP) in a variety of seismic exploration applications. Seismic sources used were surface air guns, vibrators, explosives, marine air guns, and downhole air guns. Source offsets have ranged from 100 to 7800 ft. Well depths have been from 1200 to over 10,000 ft. We have found three specific ways in which VSPs can be applied to seismic exploration. First, seismic events observed at the surface of the ground can be traced, level by level, to their point of origin within the earth. Thus, one can tie a surface profile to a well log with an extraordinarily high degree of confidence. Second, one can establish the detectability of a target horizon, such as a porous zone. One can determine (either before or after surface profiling) whether or not a given horizon or layered sequence returns a detectable reflection to the surface. The amplitude and character of the reflection can also be observed. Third, acoustic properties of a stratigraphic sequence can be measured and sometimes correlated to important exploration parameters. For example, sometimes a relationship between apparent attenuation and sand percentage can be established. The technique shows additional promise of aiding surface exploration indirectly through studies of the evolution of the seismic pulse, studies of ghosts and multiples, and studies of seismic trace inversion techniques. Nearly all current seismic data‐processing techniques are adaptable to the processing of VSP data, such as normal moveout (NMO) corrections, stacking, single‐and multiple‐channel filtering, deconvolution, and wavelet shaping.
Heeney, J L; Evermann, J F; McKeirnan, A J; Marker-Kraus, L; Roelke, M E; Bush, M; Wildt, D E; Meltzer, D G; Colly, L; Lukas, J
1990-01-01
The extent and progression of exposure to feline infectious peritonitis (FIP) virus in the cheetah, Acinonyx jubatus, was monitored by a world-wide serological survey with indirect fluorescent antibody titers to coronavirus. The indirect fluorescent antibody assay was validated by Western blots, which showed that all indirect fluorescent antibody-positive cheetah sera detected both domestic cat and cheetah coronavirus structural proteins. There was a poor correlation between indirect fluorescent antibody results and the presence of coronaviruslike particles in cheetah feces, suggesting that electron microscopic detection of shed particles may not be an easily interpreted diagnostic parameter for FIP disease. Low, but verifiable (by Western blots [immunoblots]) antibody titers against coronavirus were detected in eight free-ranging cheetahs from east Africa as well as from captive cheetahs throughout the world. Of 20 North American cheetah facilities screened, 9 had cheetahs with measurable antibodies to feline coronavirus. Five facilities showed patterns of an ongoing epizootic. Retrospective FIP virus titers of an FIP outbreak in a cheetah-breeding facility in Oregon were monitored over a 5-year period and are interpreted here in terms of clinical disease progression. During that outbreak the morbidity was over 90% and the mortality was 60%, far greater than any previously reported epizootic of FIP in any cat species. Age of infection was a significant risk factor in this epizootic, with infants (less than 3 months old) displaying significantly higher risk for mortality than subadults or adults. Based upon these observations, empirical generalizations are drawn which address epidemiologic concerns for cheetahs in the context of this lethal infectious agent. Images PMID:2157864
Jefferies, Ryan; Morgan, Eric R; Helm, Jenny; Robinson, Matthew; Shaw, Susan E
2011-12-01
This study reports the development of a real-time PCR assay and an indirect ELISA to improve on current detection of canine Angiostrongylus vasorum infection. A highly specific fluorescent probe-based, real-time PCR assay was developed to target the A. vasorum second internal transcribed spacer region and detected DNA in EDTA blood, lung tissue, broncho-alveolar larvage fluid, endotracheal mucus, pharyngeal swabs and faecal samples. PCR was fast (∼1 h), highly efficient when using EDTA blood samples, consistently detected a single molecule of parasite DNA and did not amplify DNA from other parasitic nematodes or definitive host species. An indirect ELISA was also developed using the soluble protein fraction from adult A. vasorum worms. Some cross-reactive antigen recognition was observed when tested against sera from dogs infected with Crenosoma vulpis (n = 8), Toxocara canis (n = 5) and Dirofilaria immitis (n = 5). This was largely overcome by setting the cut-off for a positive result at an appropriately high level. Field evaluation of the real-time PCR and ELISA was conducted by testing sera and EDTA blood from dogs with suspected A. vasorum infection (n = 148) and compared with the Baermann's larval migration test in faeces. Thirty-one dogs were positive by at least one test. Of these, 20 (65%) were detected by the Baermann method, 18 (58%) by blood PCR, 24 (77%) by ELISA and 28 (90%) by blood PCR and ELISA together. Combined testing using real-time PCR and ELISA therefore improved the detection rate of A. vasorum infection and holds promise for improved clinical diagnosis and epidemiological investigation.
Indirect Estimation of Radioactivity in Containerized Cargo
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jarman, Kenneth D.; Scherrer, Chad; Smith, Eric L.
Detecting illicit nuclear and radiological material in containerized cargo challenges the state of the art in detection systems. Current systems are being evaluated and new systems envisioned to address the need for the high probability of detection and extremely low false alarm rates necessary to thwart potential threats and extremely low nuisance and false alarm rates while maintaining necessary to maintain the flow of commerce impacted by the enormous volume of commodities imported in shipping containers. Maintaining flow of commerce also means that primary inspection must be rapid, requiring relatively indirect measurements of cargo from outside the containers. With increasingmore » information content in such indirect measurements, it is natural to ask how the information might be combined to improved detection. Toward this end, we present an approach to estimating isotopic activity of naturally occurring radioactive material in cargo grouped by commodity type, combining container manifest data with radiography and gamma spectroscopy aligned to location along the container. The heart of this approach is our statistical model of gamma counts within peak regions of interest, which captures the effects of background suppression, counting noise, convolution of neighboring cargo contributions, and down-scattered photons to provide physically constrained estimates of counts due to decay of specific radioisotopes in cargo alone. Coupled to that model, we use a mechanistic model of self-attenuated radiation flux to estimate the isotopic activity within cargo, segmented by location within each container, that produces those counts. We demonstrate our approach by applying it to a set of measurements taken at the Port of Seattle in 2006. This approach to synthesizing disparate available data streams and extraction of cargo characteristics holds the potential to improve primary inspection using current detection capabilities and to enable simulation-based evaluation of new candidate detection systems.« less
Antibody class capture assays for varicella-zoster virus.
Forghani, B; Myoraku, C K; Dupuis, K W; Schmidt, N J
1984-01-01
Pooled monoclonal antibodies to varicella-zoster virus (VZV) were used as "detector" antibodies in a four-phase enzyme immunofluorescence assay for determination of immunoglobulin M (IgM), IgA, and IgG antibodies to VZV. Polyclonal antisera specific for heavy chains of human IgM, IgA, and IgG were employed as "capture" antibodies on the solid phase. The antibody class capture assay (ACCA) for VZV IgM antibody detected high titers of virus-specific IgM in all patients with varicella and in 5 of 10 zoster patients. VZV IgM antibody was not detected in patients with primary herpes simplex virus infections or in other individuals without active VZV infection, with one exception, a patient with encephalitis who had other serological findings compatible with a reactivated VZV infection. VZV-specific IgA and IgG antibody titers demonstrable by ACCA were compared with those measured by solid-phase indirect enzyme immunofluorescence assay (EIFA). VZV IgA antibody titers detected in patients with varicella and zoster were variable and could not be considered to be reliable markers of active VZV infection. IgA antibody titers detected by ACCA tended to be higher than those demonstrated by solid-phase indirect EIFA in varicella and zoster patients. VZV IgG antibody titers detected by ACCA in patients with varicella, and to a lesser extent in zoster patients, were as high as or higher than those demonstrated by solid-phase indirect EIFA. However, ACCA was totally insensitive in detecting VZV IgG antibody in individuals with past infections with VZV and would not be a suitable approach for determination of immunity status to VZV. PMID:6330163
OMICS-strategies and methods in the fight against doping.
Reichel, Christian
2011-12-10
During the past decade OMICS-methods not only continued to have their impact on research strategies in life sciences and in particular molecular biology, but also started to be used for anti-doping control purposes. Research activities were mainly reasoned by the fact that several substances and methods, which were prohibited by the World Anti-Doping Agency (WADA), were or still are difficult to detect by direct methods. Transcriptomics, proteomics, and metabolomics in theory offer ideal platforms for the discovery of biomarkers for the indirect detection of the abuse of these substances and methods. Traditionally, the main focus of transcriptomics and proteomics projects has been on the prolonged detection of the misuse of human growth hormone (hGH), recombinant erythropoietin (rhEpo), and autologous blood transfusion. An additional benefit of the indirect or marker approach would also be that similarly acting substances might then be detected by a single method, without being forced to develop new direct detection methods for new but comparable prohibited substances (as has been the case, e.g. for the various forms of Epo analogs and biosimilars). While several non-OMICS-derived parameters for the indirect detection of doping are currently in use, for example the blood parameters of the hematological module of the athlete's biological passport, the outcome of most non-targeted OMICS-projects led to no direct application in routine doping control so far. The main reason is the inherent complexity of human transcriptomes, proteomes, and metabolomes and their inter-individual variability. The article reviews previous and recent research projects and their results and discusses future strategies for a more efficient application of OMICS-methods in doping control. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Iliescu, D; Comănescu, A; Antsaklis, P; Tudorache, Stefania; Ghiluşi, Mirela; Comănescu, Violeta; Paulescu, Daniela; Ceauşu, Iuliana; Antsaklis, A; Novac, Liliana; Cernea, N
2011-01-01
Morphological investigation of the central nervous system (CNS) in fetuses with positive markers for open spina bifida (OSB) detection, visualized by ultrasound during the first trimester of pregnancy. Data from fetuses that underwent routine first trimester ultrasound scan in our center during September 2007-March 2011 and presented abnormal aspects of the fourth ventricle, also referred as intracranial translucency (IT), provided the morphological support to evaluate CNS features. A neuro-histological study of posterior cerebral fossa illustrated anatomical features of the structures involved in the sonographic first trimester detection of neural tube defects. Abnormal IT aspects were found in OSB cases examined in the first trimester, but also in other severe cerebral abnormalities. Brain stem antero-posterior diameter (BS) and brain stem to occipital bone (BSOB) ratio may be more specific for OSB detection. Correlations between histological aspects of posterior brain fossa and ultrasound standard assessment have been made; highlighting the anatomical features involved by the new techniques developed for OSB early detection. Preliminary results show that modern sonographic protocols are capable to detect abnormalities in the morphometry of the posterior brain. First trimester fourth ventricle abnormalities should be followed by careful CNS evaluation because are likely to appear in OSB affected fetuses, but also in other CNS severe anomalies; in such cases, normal BS and BSOB ratio may serve as indirect argument for spine integrity, if specificity is confirmed in large series of fetuses.
Novel method for quantitative ANA measurement using near-infrared imaging.
Peterson, Lisa K; Wells, Daniel; Shaw, Laura; Velez, Maria-Gabriela; Harbeck, Ronald; Dragone, Leonard L
2009-09-30
Antinuclear antibodies (ANA) have been detected in patients with systemic rheumatic diseases and are used in the screening and/or diagnosis of autoimmunity in patients as well as mouse models of systemic autoimmunity. Indirect immunofluorescence (IIF) on HEp-2 cells is the gold standard for ANA screening. However, its usefulness is limited in diagnosis, prognosis and monitoring of disease activity due to the lack of standardization in performing the technique, subjectivity in interpreting the results and the fact that it is only semi-quantitative. Various immunological techniques have been developed in an attempt to improve upon the method to quantify ANA, including enzyme-linked immunosorbent assays (ELISAs), line immunoassays (LIAs), multiplexed bead immunoassays and IIF on substrates other than HEp-2 cells. Yet IIF on HEp-2 cells remains the most common screening method for ANA. In this study, we describe a simple quantitative method to detect ANA which combines IIF on HEp-2 coated slides with analysis using a near-infrared imaging (NII) system. Using NII to determine ANA titer, 86.5% (32 of 37) of the titers for human patient samples were within 2 dilutions of those determined by IIF, which is the acceptable range for proficiency testing. Combining an initial screening for nuclear staining using microscopy with titration by NII resulted in 97.3% (36 of 37) of the titers detected to be within two dilutions of those determined by IIF. The NII method for quantitative ANA measurements using serum from both patients and mice with autoimmunity provides a fast, relatively simple, objective, sensitive and reproducible assay, which could easily be standardized for comparison between laboratories.
Detection of autoimmunity in early primary Epstein-Barr virus infection by Western blot analysis.
Mascia, M T; Sandri, G; Guerzoni, C; Roncaglia, R; Mantovani, G; Ferri, C
2008-01-01
The Epstein-Barr virus (EBV) represents a potentially important factor in the pathogenesis of certain autoimmune disorders such as systemic lupus erythematosus (SLE), and Sjögren's syndrome, probably through a molecular mimicry mechanism. Several studies have focused on the relationship between previous EBV infection and clinically overt connective tissue diseases (CTDs), while the aim of this study was to investigate the immunological alterations during the early phase of primary acute EBV infection by means of ENA Western blotting (WB) analysis. This technique is able to detect a wide spectrum of anti-ENA autoantibodies, potentially directed against diverse epitopes of the same antigen. Sera from 54 subjects (F/M=24/30, mean age 17+/-6 SD years) with primary acute EBV infection were analysed using indirect immunofluorescence (IF) on Hep-2 cells for ANA, and both ELISA and WB for ENA. Only 8 ANA+ and no ENA+ were found by means of IF and ELISA techniques, respectively; however, one or more ENA autoantibodies were detected in 24/54 (44%) sera using WB. The autoantibodies were no longer present at the second evaluation. Subjects with immunological alterations had not developed any significant clinical manifestations at a 5-year follow-up. This study demonstrated the appearance of autoantibody production in a high proportion of individuals with primary acute EBV infection; interestingly, the observed serological subsets are quite similar to clinical SLE clusters. Moreover, the absence of immunological disorders during the follow-up reinforces the role of multiple genetic and/or environmental co-factors in the pathogenesis of CTDs.
Direct and Indirect Dark Matter Detection in Gauge Theories (in Portuguese)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Queiroz, Farinaldo
The Dark matter (DM) problem constitutes a key question at the interface among Particle Physics, Astrophysics and Cosmology. The observational data which have been accumulated in the last years point to an existence of non baryonic amount of DM. Since the Standard Model (SM) does not provide any candidate for such non-baryonic DM, the evidence of DM is a major indication for new physics beyond the SM. We will study in this work one of the most popular DM candidates, the so called WIMPs (Weakly Interacting Massive Particles) from a direct and indirect detection perspective. In order to approach themore » direct and indirect dection of DM in the context of Particle Physics in a more pedagogic way, we will begin our discussion talking about a minimal extension of the SM. Later we will work on the subject in a 3-3-1 model. Next, we will study the role of WIMPs in the Big Bang Nucleosynthesis. Lastly, we will look for indirect DM signals in the center of our galaxy using the NASA Satellite, called Fermi-LAT. Through a comprehensive analysis of the data events observed by Fermi-LAT and some background models, we will constrain the dark matter annihilation cross section for several annihilation channels and dark matter halo profiles.« less
Salience of the Nuclear Threat: Operationalization through Spontaneous Concern.
ERIC Educational Resources Information Center
Mayton, Daniel M., II
An indirect/nonreactive technique of assessing spontaneous concern should be used to examine the salience of the threat of nuclear war. Direct/reactive techniques may produce inconsistent results and inadvertently enhance a false consensus. The procedures for the administration, scoring, and interpretation of a spontaneous concern measure along…
48 CFR 9905.506-50 - Techniques for application.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... 9905.506-50 Section 9905.506-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD... ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS FOR EDUCATIONAL INSTITUTIONS 9905.506-50 Techniques for application. (a) The cost of an indirect function which exists for only a part of a cost accounting period may...
Symbol Tables and Branch Tables: Linking Applications Together
NASA Technical Reports Server (NTRS)
Handler, Louis M.
2011-01-01
This document explores the computer techniques used to execute software whose parts are compiled and linked separately. The computer techniques include using a branch table or indirect address table to connect the parts. Methods of storing the information in data structures are discussed as well as differences between C and C++.
A Field-Based Technique for Teaching about Habitat Fragmentation and Edge Effects
ERIC Educational Resources Information Center
Resler, Lynn M.; Kolivras, Korine N.
2009-01-01
This article presents a field technique that exposes students to the indirect effects of habitat fragmentation on plant distributions through studying edge effects. This assignment, suited for students in an introductory biogeography or resource geography class, increases students' knowledge of basic biogeographic concepts such as environmental…
Tonolini, Massimo; Ierardi, Anna Maria; Bracchi, Elena; Magistrelli, Paolo; Vella, Adriana; Carrafiello, Gianpaolo
2017-10-01
Despite availability of effective therapies, peptic ulcer disease (PUD) remains a major global disease, resulting from a combination of persistent Helicobacter pylori infection and widespread use of nonsteroidal anti-inflammatory drugs. Albeit endoscopy definitely represents the mainstay diagnostic technique, patients presenting to emergency departments with unexplained abdominal pain generally undergo multidetector CT as an initial investigation. Although superficial ulcers generally remain inconspicuous, careful multiplanar CT interpretation may allow to detect deep ulcers, secondary mural and extraluminal signs of peptic gastroduodenitis, thereby allowing timely endoscopic verification and appropriate treatment. This pictorial essay aims to provide radiologists with an increased familiarity with CT diagnosis of non-perforated PUD, with emphasis on differential diagnosis. Following an overview of current disease epidemiology and complications, it explains the appropriate CT acquisition and interpretation techniques, and reviews with several examples the cross-sectional findings of uncomplicated PUD. Afterwards, the CT features of PUD complications such as ulcer haemorrhage, gastric outlet obstruction, biliary and pancreatic fistulisation are presented. • Gastric and duodenal peptic ulcers are increasingly caused by nonsteroidal anti-inflammatory drugs • Multiplanar CT interpretation allows detecting deep ulcers and secondary signs of gastroduodenitis • CT diagnosis of uncomplicated peptic disease relies on direct and indirect signs • Currently the commonest complication, haemorrhage may be treated with transarterial embolisation • Other uncommon complications include gastric outlet obstruction and biliopancreatic fistulisation.
USDA-ARS?s Scientific Manuscript database
Infectious agents or their constituent parts (antigens or nucleic acids) can be detected in fresh, frozen, or fixed tissues or other specimens, using a variety of direct or indirect assays. The assays can be modified to yield the greatest sensitivity and specificity but in most cases a particular m...
DOT National Transportation Integrated Search
2014-08-01
A proof of concept was established for a sensor capable of using indirect impedance spectroscopy to : detect the existence of corrosion in post-tensioned tendons. This development was supported by a : combination of bench-top experiments performed on...
Jankásková, J; Horváth, O N; Varga, R; Arenberger, P; Schmidt, E; Ruzicka, T; Sárdy, M
2018-04-01
Indirect immunofluorescence (IIF) microscopy on monkey oesophagus is an important assay for the diagnosis of bullous pemphigoid (BP). Its relatively low sensitivity (60-80%) may be partly due to insufficient detection of minor IgG subclasses. To determine the operating characteristics of an IgG subclass in IIF. We designed a retrospective, dual-centre, controlled cohort study on sera from 64 BP sera that had been rated as false negatives by traditional IIF microscopy, and assessed circulating IgG 1 , IgG 3 and IgG 4 autoantibodies. The sensitivities of IIF in detecting IgG 1 , IgG 3 , IgG 4 and all three in combination were 45.3%, 18.8%, 32.8% and 48.4%, respectively. Specificities were > 97%. Detection of IgG subclass (especially IgG 1 and IgG 4 ) autoantibodies by IIF on monkey oesophagus can significantly improve diagnostic performance of IIF microscopy for diagnosis of BP. © 2018 British Association of Dermatologists.
A Method for Direct Fabrication of a Lingual Splint for Management of Pediatric Mandibular Fractures
Davies, Sarah; Costello, Bernard J.
2013-01-01
Summary: Pediatric mandibular fractures have successfully been managed in various ways. The use of a lingual splint is one such option. The typical indirect method for acrylic lingual splint fabrication involves obtaining dental impressions. Dental models are produced from those impressions so that model surgery may be performed. The splint is then made on those models using resin powder and liquid monomer in a wet laboratory and transferred to the patient. Obvious limitations to this technique exist for both patient and operator. We present a technique for direct, intraoperative, fabrication of a splint using commercially available light-cured material that avoids some of the shortcomings of the indirect method. Recommendations are made based on available material safety information. PMID:25289246
Experience with novel technologies for direct measurement of atmospheric NO2
NASA Astrophysics Data System (ADS)
Hueglin, Christoph; Hundt, Morten; Mueller, Michael; Schwarzenbach, Beat; Tuzson, Bela; Emmenegger, Lukas
2017-04-01
Nitrogen dioxide (NO2) is an air pollutant that has a large impact on human health and ecosystems, and it plays a key role in the formation of ozone and secondary particulate matter. Consequently, legal limit values for NO2 are set in the EU and elsewhere, and atmospheric observation networks typically include NO2 in their measurement programmes. Atmospheric NO2 is principally measured by chemiluminescence detection, an indirect measurement technique that requires conversion of NO2 into nitrogen monoxide (NO) and finally calculation of NO2 from the difference between total nitrogen oxides (NOx) and NO. Consequently, NO2 measurements with the chemiluminescence method have a relatively high measurement uncertainty and can be biased depending on the selectivity of the applied NO2 conversion method. In the past years, technologies for direct and selective measurement of NO2 have become available, e.g. cavity attenuated phase shift spectroscopy (CAPS), cavity enhanced laser absorption spectroscopy and quantum cascade laser absorption spectrometry (QCLAS). These technologies offer clear advantages over the indirect chemiluminescence method. We tested the above mentioned direct measurement techniques for NO2 over extended time periods at atmospheric measurement stations and report on our experience including comparisons with co-located chemiluminescence instruments equipped with molybdenum as well as photolytic NO2 converters. A still open issue related to the direct measurement of NO2 is instrument calibration. Accurate and traceable reference standards and NO2 calibration gases are needed. We present results from the application of different calibration strategies based on the use of static NO2 calibration gases as well as dynamic NO2 calibration gases produced by permeation and by gas-phase titration (GPT).
Mazzoni, Simona; Marchetti, Claudio; Sgarzani, Rossella; Cipriani, Riccardo; Scotti, Roberto; Ciocca, Leonardo
2013-06-01
The aim of the present study was to evaluate the accuracy of prosthetically guided maxillofacial surgery in reconstructing the mandible with a free vascularized flap using custom-made bone plates and a surgical guide to cut the mandible and fibula. The surgical protocol was applied in a study group of seven consecutive mandibular-reconstructed patients who were compared with a control group treated using the standard preplating technique on stereolithographic models (indirect computer-aided design/computer-aided manufacturing method). The precision of both surgical techniques (prosthetically guided maxillofacial surgery and indirect computer-aided design/computer-aided manufacturing procedure) was evaluated by comparing preoperative and postoperative computed tomographic data and assessment of specific landmarks. With regard to midline deviation, no significant difference was documented between the test and control groups. With regard to mandibular angle shift, only one left angle shift on the lateral plane showed a statistically significant difference between the groups. With regard to angular deviation of the body axis, the data showed a significant difference in the arch deviation. All patients in the control group registered greater than 8 degrees of deviation, determining a facial contracture of the external profile at the lower margin of the mandible. With regard to condylar position, the postoperative condylar position was better in the test group than in the control group, although no significant difference was detected. The new protocol for mandibular reconstruction using computer-aided design/computer-aided manufacturing prosthetically guided maxillofacial surgery to construct custom-made guides and plates may represent a viable method of reproducing the patient's anatomical contour, giving the surgeon better procedural control and reducing procedure time. Therapeutic, III.
Bex, Axel; Fournier, Laure; Lassau, Nathalie; Mulders, Peter; Nathan, Paul; Oyen, Wim J G; Powles, Thomas
2014-04-01
The introduction of targeted agents for the treatment of renal cell carcinoma (RCC) has resulted in new challenges for assessing response to therapy, and conventional response criteria using computed tomography (CT) are limited. It is widely recognised that targeted therapies may lead to significant necrosis without significant reduction in tumour size. In addition, the vascular effects of antiangiogenic therapy may occur long before there is any reduction in tumour size. To perform a systematic review of conventional and novel imaging methods for the assessment of response to targeted agents in RCC and to discuss their use from a clinical perspective. Relevant databases covering the period January 2006 to April 2013 were searched for studies reporting on the use of anatomic and functional imaging techniques to predict response to targeted therapy in RCC. Inclusion criteria were randomised trials, nonrandomised controlled studies, retrospective case series, and cohort studies. Reviews, animal and preclinical studies, case reports, and commentaries were excluded. A narrative synthesis of the evidence is presented. A total of 331 abstracts and 76 full-text articles were assessed; 34 studies met the inclusion criteria. Current methods of response assessment in RCC include anatomic methods--based on various criteria including Choi, size and attenuation CT, and morphology, attenuation, size, and structure--and functional techniques including dynamic contrast-enhanced (DCE) CT, DCE-magnetic resonance imaging, DCE-ultrasonography, positron emission tomography, and approaches utilising radiolabelled monoclonal antibodies. Functional imaging techniques are promising surrogate biomarkers of response in RCC and may be more appropriate than anatomic CT-based methods. By enabling quantification of tumour vascularisation, functional techniques can directly and rapidly detect the biologic effects of antiangiogenic therapies compared with the indirect detection of belated effects on tumour size by anatomic methods. However, larger prospective studies are needed to validate early results and standardise techniques. Copyright © 2013 European Association of Urology. All rights reserved.
Electrophoresis-chemiluminescence detection of phenols catalyzed by hemin.
Shu, Lu; Zhu, Jinkun; Wang, Qingjiang; He, Pingang; Fang, Yuzhi
2014-09-01
Based on the catalytic activity of hemin, an efficient biocatalyst, an indirect capillary electrophoresis-chemiluminescence (CE-CL) detection method for phenols using a hemin-luminol-hydrogen peroxide system was developed. Through a series of static injection experiments, hemin was found to perform best in a neutral solution rather than an acidic or alkaline medium. Although halide ions such as Br(-) and F(-) could further enhance the CL signal catalyzed by hemin, it is difficult to apply these conditions to this CE-CL detection system because of the self-polymerization of hemin, as it hinders the CE process. The addition of concentrated ammonium hydroxide to an aqueous/dimethyl sulfoxide solution of hemin-luminol afforded a stable CE-CL baseline. The indirect CE-CL detection of five phenols using this method gave the following limits of detections: 4.8 × 10(-8) mol/L (o-sec-butylphenol), 4.9 × 10(-8) mol/L (o-cresol), 5.4 × 10(-8) mol/L (m-cresol), 5.3 × 10(-8) mol/L (2,4-dichlorophenol) and 7.1 × 10(-8) mol/L (phenol). Copyright © 2013 John Wiley & Sons, Ltd.
Network meta-analysis: a technique to gather evidence from direct and indirect comparisons
2017-01-01
Systematic reviews and pairwise meta-analyses of randomized controlled trials, at the intersection of clinical medicine, epidemiology and statistics, are positioned at the top of evidence-based practice hierarchy. These are important tools to base drugs approval, clinical protocols and guidelines formulation and for decision-making. However, this traditional technique only partially yield information that clinicians, patients and policy-makers need to make informed decisions, since it usually compares only two interventions at the time. In the market, regardless the clinical condition under evaluation, usually many interventions are available and few of them have been studied in head-to-head studies. This scenario precludes conclusions to be drawn from comparisons of all interventions profile (e.g. efficacy and safety). The recent development and introduction of a new technique – usually referred as network meta-analysis, indirect meta-analysis, multiple or mixed treatment comparisons – has allowed the estimation of metrics for all possible comparisons in the same model, simultaneously gathering direct and indirect evidence. Over the last years this statistical tool has matured as technique with models available for all types of raw data, producing different pooled effect measures, using both Frequentist and Bayesian frameworks, with different software packages. However, the conduction, report and interpretation of network meta-analysis still poses multiple challenges that should be carefully considered, especially because this technique inherits all assumptions from pairwise meta-analysis but with increased complexity. Thus, we aim to provide a basic explanation of network meta-analysis conduction, highlighting its risks and benefits for evidence-based practice, including information on statistical methods evolution, assumptions and steps for performing the analysis. PMID:28503228
Application of photo-detection to art and archaeology at the C2RMF
NASA Astrophysics Data System (ADS)
Calligaro, T.; Dran, J.-C.; Klein, M.
2003-05-01
The Centre for research and restoration of the museums of France (C2RMF), located in the Louvre palace in Paris routinely uses photodetector-based techniques for the study of objects of cultural heritage. Among these methods, the ion beam analysis techniques (IBA) provided by the 2-MV electrostatic accelerator "AGLAE" installed in the C2RMF have the specific qualities required for the study of these valuable objects. Indeed, PIXE and PIGE are non-destructive, non-invasive, rapid and sensitive tools for the determination of the chemical composition. Their use enables to answer three major questions in the field of Art and Archaeology: (1) identification of the material, (2) determination of the provenance, and (3) study of surface modification (ageing, alteration). Applications of radiation detectors are exemplified through case studies performed at the Centre: the identification of the pigments used on an Egyptian papyrus, the provenance of gemstones set on ancient jewels and the indirect dating of archaeological flints. New trends in the use of photo-detectors in Art and Archaeology are presented.
Mumtaz, Sidra; Khan, Laiq; Ahmed, Saghir; Bader, Rabiah
2017-01-01
This paper focuses on the indirect adaptive tracking control of renewable energy sources in a grid-connected hybrid power system. The renewable energy systems have low efficiency and intermittent nature due to unpredictable meteorological conditions. The domestic load and the conventional charging stations behave in an uncertain manner. To operate the renewable energy sources efficiently for harvesting maximum power, instantaneous nonlinear dynamics should be captured online. A Chebyshev-wavelet embedded NeuroFuzzy indirect adaptive MPPT (maximum power point tracking) control paradigm is proposed for variable speed wind turbine-permanent synchronous generator (VSWT-PMSG). A Hermite-wavelet incorporated NeuroFuzzy indirect adaptive MPPT control strategy for photovoltaic (PV) system to extract maximum power and indirect adaptive tracking control scheme for Solid Oxide Fuel Cell (SOFC) is developed. A comprehensive simulation test-bed for a grid-connected hybrid power system is developed in Matlab/Simulink. The robustness of the suggested indirect adaptive control paradigms are evaluated through simulation results in a grid-connected hybrid power system test-bed by comparison with conventional and intelligent control techniques. The simulation results validate the effectiveness of the proposed control paradigms.
Khan, Laiq; Ahmed, Saghir; Bader, Rabiah
2017-01-01
This paper focuses on the indirect adaptive tracking control of renewable energy sources in a grid-connected hybrid power system. The renewable energy systems have low efficiency and intermittent nature due to unpredictable meteorological conditions. The domestic load and the conventional charging stations behave in an uncertain manner. To operate the renewable energy sources efficiently for harvesting maximum power, instantaneous nonlinear dynamics should be captured online. A Chebyshev-wavelet embedded NeuroFuzzy indirect adaptive MPPT (maximum power point tracking) control paradigm is proposed for variable speed wind turbine-permanent synchronous generator (VSWT-PMSG). A Hermite-wavelet incorporated NeuroFuzzy indirect adaptive MPPT control strategy for photovoltaic (PV) system to extract maximum power and indirect adaptive tracking control scheme for Solid Oxide Fuel Cell (SOFC) is developed. A comprehensive simulation test-bed for a grid-connected hybrid power system is developed in Matlab/Simulink. The robustness of the suggested indirect adaptive control paradigms are evaluated through simulation results in a grid-connected hybrid power system test-bed by comparison with conventional and intelligent control techniques. The simulation results validate the effectiveness of the proposed control paradigms. PMID:28877191
Ozkan, Serkan; Bayram, Mehmet
2016-11-01
We compared the effectiveness of 2 canine retraction springs and anchorage systems (direct and indirect skeletal anchorage) in patients requiring first premolar extractions and maximum anchorage in the maxilla. Thirty-six patients were included (17 male, 19 female; mean age, 16.8 ± 2.4 years). A mini-implant-supported Nance appliance with indirect skeletal anchorage system was used in 18 patients and a mini-implant-supported direct skeletal anchorage system in the remaining patients. In each patient, a segmental retraction arch with a reverse closing loop was applied to a maxillary canine, and a Ladanyi spring (Dentaurum, Ispringen, Germany) was applied to the other canine randomly after extraction of the maxillary first premolars. The retraction process was continued until a Class I canine relationship was obtained. Lateral cephalometric films and orthodontic casts taken before and after retraction in the distalization process were used to evaluate changes during canine distalization. The measurements were statistically evaluated using paired and independent t tests with 95% confidence intervals. The reverse closing loop and the Ladanyi spring were found to be effective in canine distalization (P ≤0.001). There were no statistically significant differences between the reverse closing loop and the Ladanyi spring with regard to canine distalization rates (P ≥0.05). Both systems were effective in providing maximum anchorage (P ≥0.05); no statistically significant differences were detected in molar anchorage loss rates between the 2 methods (P ≥0.05). These 2 systems can be used during segmental distalization of canines requiring maximum anchorage with no significant anchorage loss. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Seshadri, S.; Buehler, M. G.; Anderson, R. C.; Kuhlman, G. M.; Keymeulen, D.; Cheung, I. W.; Schaap, M. G.
2005-01-01
The search for life is a primary goal of NASA s planetary exploration program. The search is, of necessity, tiered in both the detection approach (looking for evidence of microbial fossils or the presence of water in the geological history of a planetary body and/or looking for evidence of water, energy sources, precursors to life, signatures of life and/or life itself in the present day planetary environment) and in the survey method (scale, range, specificity) employed. Terrestrial investigations suggests that life as we know it requires water. Thus, the search for extant microbial life and habitats requires identifying water-bearing soils. Determining Reduction-Oxidation (REDOX) couples present in water, once it is found, provides information on soil geochemistry and identifies potential chemical energy sources for life. Mars offers a near-term target for conducting this search. The identification of gully formation [1], layered deposits [2] and elemental ratios of bromine and chlorine [3] present indirect evidence that water was abundant locally in the Martian past. Additionally, Viking images of polar ice and frost formation on the surface of Mars demonstrate that water can exist in at least some near-surface regions of present-day Mars. Atmospheric pressure data further suggest that liquid water may be stable for short periods of time in the mid-latitudes of the Martian surface. [4] Measurements of the global distribution of hydrogen in the Martian regolith offer tantalizing indirect evidence that water may at least exist in near-surface soils. [5] Evidently, any water to be found is likely to exist as soil mixtures at levels ranging between approx.0.5% and approx.5 %.
Serological study of brucellosis in Argentine Creole sheep.
López, Gustavo E; Peña, Sabrina; Escobar, Gabriela I; Hasan, Déborah B; Lucero, Nidia E
2018-01-05
Ovine cattle was introduced into America during the Spanish conquest with the second journey of Columbus to the Antilles and was disseminated throughout the region. In 1587, sheep were introduced into Argentina, later developing into the "Creole" breed. We selected 486 animals from different Argentine provinces with the aim of determining the serological status of brucellosis caused by Brucella melitensis and Brucella ovis. For the detection of antibodies against smooth Brucella spp., the Rose Bengal test (RBT) was performed as screening test while the serum agglutination test (SAT) and 2 mercapto-ethanol (2ME) were run as a confirmatory technique. Moreover, for the detection of antibodies against rough Brucella spp., we used the rapid slide agglutination test (RSAT) for screening and an indirect ELISA (IELISA) as confirmatory assay. This study showed that the total positive percentage of brucellosis due to B. ovis was 2.9%. Excluding the animals mixed with the Suffolk breed; seropositivity would be 0.6%. All animals tested negative for brucellosis caused by B. melitensis. Copyright © 2017 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.
Yang, Jianmin; Li, Hai-Fang; Li, Meilan; Lin, Jin-Ming
2012-08-21
The presence of inorganic elements in fuel gas generally accelerates the corrosion and depletion of materials used in the fuel gas industry, and even leads to serious accidents. For identification of existing trace inorganic contaminants in fuel gas in a portable way, a highly efficient gas-liquid sampling collection system based on gas dispersion concentration is introduced in this work. Using the constructed dual path gas-liquid collection setup, inorganic cations and anions were simultaneously collected from real liquefied petroleum gas (LPG) and analyzed by capillary electrophoresis (CE) with indirect UV absorbance detection. The head-column field-amplified sample stacking technique was applied to improve the detection limits to 2-25 ng mL(-1). The developed collection and analytical methods have successfully determined existing inorganic contaminants in a real LPG sample in the range of 4.59-138.69 μg m(-3). The recoveries of cations and anions with spiked LPG samples were between 83.98 and 105.63%, and the relative standard deviations (RSDs) were less than 7.19%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roszkowski, Leszek; Trojanowski, Sebastian; Turzyński, Krzysztof, E-mail: leszek.roszkowski@ncbj.gov.pl, E-mail: sebastian.trojanowski@uci.edu, E-mail: Krzysztof-Jan.Turzynski@fuw.edu.pl
We examine the question to what extent prospective detection of dark matter by direct and indirect- detection experiments could shed light on what fraction of dark matter was generated thermally via the freeze-out process in the early Universe. By simulating putative signals that could be seen in the near future and using them to reconstruct WIMP dark matter properties, we show that, in a model- independent approach this could only be achieved in a thin sliver of the parameter space. However, with additional theoretical input the hypothesis about the thermal freeze-out as the dominant mechanism for generating dark matter canmore » potentially be verified. We illustrate this with two examples: an effective field theory of dark matter with a vector messenger and a higgsino or wino dark matter within the MSSM.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Chian-Shu; Department of Physics, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu, Taiwan, 30010 R.O.C.; Institute of Physics, Academia Sinica, 128 Sec. 2,Academia Rd., Nangang, Taipei, Taiwan, 11529 R.O.C.
2016-01-07
The halo dark matter (DM) can be captured by the Sun if its final velocity after the collision with a nucleus in the Sun is less than the escape velocity. We consider a selfinteracting dark matter (SIDM) model where U(1) gauge symmetry is introduced to account for the DM self-interaction. Such a model naturally leads to isospin violating DM-nucleon interaction, although isospin symmetric interaction is still allowed as a special case. We present the IceCube-PINGU 2σ sensitivity to the parameter range of the above model with 5 years of search for neutrino signature from DM annihilation in the Sun. Thismore » indirect detection complements the direct detection by probing those SIDM parameter ranges which are either the region for very small m{sub χ} or the region opened up due to isospin violations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Chian-Shu; Lin, Guey-Lin; Lin, Yen-Hsun, E-mail: chianshu@gmail.com, E-mail: glin@cc.nctu.edu.tw, E-mail: chris.py99g@g2.nctu.edu.tw
2016-01-01
The halo dark matter (DM) can be captured by the Sun if its final velocity after the collision with a nucleus in the Sun is less than the escape velocity. We consider a selfinteracting dark matter (SIDM) model where U(1) gauge symmetry is introduced to account for the DM self-interaction. Such a model naturally leads to isospin violating DM-nucleon interaction, although isospin symmetric interaction is still allowed as a special case. We present the IceCube-PINGU 2σ sensitivity to the parameter range of the above model with 5 years of search for neutrino signature from DM annihilation in the Sun. Thismore » indirect detection complements the direct detection by probing those SIDM parameter ranges which are either the region for very small m{sub χ} or the region opened up due to isospin violations.« less
Indirect detection of Particle Dark Matter with gamma rays - status and perspectives
NASA Astrophysics Data System (ADS)
Conrad, Jan
2014-03-01
In this contribution I review the present status and discuss some prospects for indirect detection of dark matter with gamma rays. Thanks mainly to the Fermi Large Area Telescope (Fermi-LAT), searches in gamma-rays have reached sensitivities that allow to probe the most interesting parameter space of the weakly interacting massive particles (WIMP) paradigm. This gain in sensitivity is naturally accompanied by a number of detection claims or indications. At WIMP masses above roughly a TeV current Imaging Air Cherenkov Telescopes (HESS, VERITAS, MAGIC) become more sensitive than the Fermi-LAT, the most promising recent development being the first light for the second phase HESS II telescope with significantly lower energy threshold. Predictions for the next generation air Cherenkov telescope, Cherenkov Telescope Array (CTA), together with forecasts on future Fermi-LAT constraints arrive at the exciting possibility that the cosmological benchmark cross-section could be probed from masses of a few GeV to a few TeV. Consequently, non-detection would pose a challenge to the WIMP paradigm, but the reached sensitivities also imply that-optimistically-a detection within the next decade is in the cards. Time allowing, I will comment on complementarity between the different approaches to WIMP detection.
Measuring situation awareness in emergency settings: a systematic review of tools and outcomes
Cooper, Simon; Porter, Joanne; Peach, Linda
2014-01-01
Background Nontechnical skills have an impact on health care outcomes and improve patient safety. Situation awareness is core with the view that an understanding of the environment will influence decision-making and performance. This paper reviews and describes indirect and direct measures of situation awareness applicable for emergency settings. Methods Electronic databases and search engines were searched from 1980 to 2010, including CINAHL, Ovid Medline, Pro-Quest, Cochrane, and the search engine, Google Scholar. Access strategies included keyword, author, and journal searches. Publications identified were assessed for relevance, and analyzed and synthesized using Oxford evidence levels and the Critical Appraisal Skills Programme guidelines in order to assess their quality and rigor. Results One hundred and thirteen papers were initially identified, and reduced to 55 following title and abstract review. The final selection included 14 papers drawn from the fields of emergency medicine, intensive care, anesthetics, and surgery. Ten of these discussed four general nontechnical skill measures (including situation awareness) and four incorporated the Situation Awareness Global Assessment Technique. Conclusion A range of direct and indirect techniques for measuring situation awareness is available. In the medical literature, indirect approaches are the most common, with situation awareness measured as part of a nontechnical skills assessment. In simulation-based studies, situation awareness in emergencies tends to be suboptimal, indicating the need for improved training techniques to enhance awareness and improve decision-making. PMID:27147872
Nguyen, Quynh C.; Osypuk, Theresa L.; Schmidt, Nicole M.; Glymour, M. Maria; Tchetgen Tchetgen, Eric J.
2015-01-01
Despite the recent flourishing of mediation analysis techniques, many modern approaches are difficult to implement or applicable to only a restricted range of regression models. This report provides practical guidance for implementing a new technique utilizing inverse odds ratio weighting (IORW) to estimate natural direct and indirect effects for mediation analyses. IORW takes advantage of the odds ratio's invariance property and condenses information on the odds ratio for the relationship between the exposure (treatment) and multiple mediators, conditional on covariates, by regressing exposure on mediators and covariates. The inverse of the covariate-adjusted exposure-mediator odds ratio association is used to weight the primary analytical regression of the outcome on treatment. The treatment coefficient in such a weighted regression estimates the natural direct effect of treatment on the outcome, and indirect effects are identified by subtracting direct effects from total effects. Weighting renders treatment and mediators independent, thereby deactivating indirect pathways of the mediators. This new mediation technique accommodates multiple discrete or continuous mediators. IORW is easily implemented and is appropriate for any standard regression model, including quantile regression and survival analysis. An empirical example is given using data from the Moving to Opportunity (1994–2002) experiment, testing whether neighborhood context mediated the effects of a housing voucher program on obesity. Relevant Stata code (StataCorp LP, College Station, Texas) is provided. PMID:25693776
The Incidence of Intravascular Needle Entrance during Inferior Alveolar Nerve Block Injection.
Taghavi Zenouz, Ali; Ebrahimi, Hooman; Mahdipour, Masoumeh; Pourshahidi, Sara; Amini, Parisa; Vatankhah, Mahdi
2008-01-01
Dentists administer thousands of local anesthetic injections every day. Injection to a highly vascular area such as pterygomandibular space during an inferior alveolar nerve block has a high risk of intravascular needle entrance. Accidental intravascular injection of local anesthetic agent with vasoconstrictor may result in cardiovascular and central nervous system toxicity, as well as tachycardia and hypertension. There are reports that indicate aspiration is not performed in every injection. The aim of the present study was to assess the incidence of intravascular needle entrance in inferior alveolar nerve block injections. Three experienced oral and maxillofacial surgeons performed 359 inferior alveolar nerve block injections using direct or indirect techniques, and reported the results of aspiration. Aspirable syringes and 27 gauge long needles were used, and the method of aspiration was similar in all cases. Data were analyzed using t-test. 15.3% of inferior alveolar nerve block injections were aspiration positive. Intravascular needle entrance was seen in 14.2% of cases using direct and 23.3% of cases using indirect block injection techniques. Of all injections, 15.8% were intravascular on the right side and 14.8% were intravascular on the left. There were no statistically significant differences between direct or indirect block injection techniques (P = 0.127) and between right and left injection sites (P = 0.778). According to our findings, the incidence of intravascular needle entrance during inferior alveolar nerve block injection was relatively high. It seems that technique and maneuver of injection have no considerable effect in incidence of intravascular needle entrance.
The Incidence of Intravascular Needle Entrance during Inferior Alveolar Nerve Block Injection
Taghavi Zenouz, Ali; Ebrahimi, Hooman; Mahdipour, Masoumeh; Pourshahidi, Sara; Amini, Parisa; Vatankhah, Mahdi
2008-01-01
Background and aims Dentists administer thousands of local anesthetic injections every day. Injection to a highly vascular area such as pterygomandibular space during an inferior alveolar nerve block has a high risk of intravascular needle entrance. Accidental intravascular injection of local anesthetic agent with vasoconstrictor may result in cardiovascular and central nervous system toxicity, as well as tachycardia and hypertension. There are reports that indicate aspiration is not performed in every injection. The aim of the present study was to assess the incidence of intravascular needle entrance in inferior alveolar nerve block injections. Materials and methods Three experienced oral and maxillofacial surgeons performed 359 inferior alveolar nerve block injections using direct or indirect techniques, and reported the results of aspiration. Aspirable syringes and 27 gauge long needles were used, and the method of aspiration was similar in all cases. Data were analyzed using t-test. Results 15.3% of inferior alveolar nerve block injections were aspiration positive. Intravascular needle entrance was seen in 14.2% of cases using direct and 23.3% of cases using indirect block injection techniques. Of all injections, 15.8% were intravascular on the right side and 14.8% were intravascular on the left. There were no statistically significant differences between direct or indirect block injection techniques (P = 0.127) and between right and left injection sites (P = 0.778). Conclusion According to our findings, the incidence of intravascular needle entrance during inferior alveolar nerve block injection was relatively high. It seems that technique and maneuver of injection have no considerable effect in incidence of intravascular needle entrance. PMID:23285329
Using Policy-Capturing to Measure Attitudes in Organizational Diagnosis.
ERIC Educational Resources Information Center
Madden, Joseph M.
1981-01-01
Discusses an indirect method of attitude measurement, policy-capturing, that can be applied on an individual basis. In three experiments this method detected prejudicial attitudes toward females not detected with traditional methods. Can be used as a self-improvement diagnostic tool for developing awareness of behavior influences. (JAC)
Dark matter in dwarf spheroidal galaxies and indirect detection: a review
NASA Astrophysics Data System (ADS)
Strigari, Louis E.
2018-05-01
Indirect dark matter searches targeting dwarf spheroidal galaxies (dSphs) have matured rapidly during the past decade. This has been because of the substantial increase in kinematic data sets from the dSphs, the new dSphs that have been discovered, and the operation of the Fermi-LAT and many ground-based gamma-ray experiments. Here we review the analysis methods that have been used to determine the dSph dark matter distributions, in particular the ‘J-factors’, comparing and contrasting them, and detailing the underlying systematics that still affect the analysis. We discuss prospects for improving measurements of dark matter distributions, and how these interplay with future indirect dark matter searches.
Dark matter in dwarf spheroidal galaxies and indirect detection: a review.
Strigari, Louis E
2018-05-01
Indirect dark matter searches targeting dwarf spheroidal galaxies (dSphs) have matured rapidly during the past decade. This has been because of the substantial increase in kinematic data sets from the dSphs, the new dSphs that have been discovered, and the operation of the Fermi-LAT and many ground-based gamma-ray experiments. Here we review the analysis methods that have been used to determine the dSph dark matter distributions, in particular the 'J-factors', comparing and contrasting them, and detailing the underlying systematics that still affect the analysis. We discuss prospects for improving measurements of dark matter distributions, and how these interplay with future indirect dark matter searches.
Effects of spaceflight and simulated weightlessness on longitudinal bone growth
NASA Technical Reports Server (NTRS)
Sibonga, J. D.; Zhang, M.; Evans, G. L.; Westerlind, K. C.; Cavolina, J. M.; Morey-Holton, E.; Turner, R. T.
2000-01-01
Indirect measurements have suggested that spaceflight impairs bone elongation in rats. To test this possibility, our laboratory measured, by the fluorochrome labeling technique, bone elongation that occurred during a spaceflight experiment. The longitudinal growth rate (LGR) in the tibia of rats in spaceflight experiments (Physiological Space Experiments 1, 3, and 4 and Physiological-Anatomical Rodent Experiment 3) and in two models of skeletal unloading (hind-limb elevation and unilateral sciatic neurotomy) were calculated. The effects of an 11 day spaceflight on gene expression of cartilage matrix proteins in rat growth plates were also determined by northern analysis and are reported for the first time in this study. Measurements of longitudinal growth indicate that skeletal unloading generally did not affect LGR, regardless of age, strain, gender, duration of unloading, or method of unloading. There was, however, one exception with 34% suppression in LGR detected in slow-growing, ovariectomized rats skeletally unloaded for 8 days by hind-limb elevation. This detection of reduced LGR by hind-limb elevation is consistent with changes in steady-state mRNA levels for type II collagen (-33%) and for aggrecan (-53%) that were detected in rats unloaded by an 11 day spaceflight. The changes detected in gene expression raise concern that spaceflight may result in changes in the composition of extracellular matrix, which could have a negative impact on conversion of growth-plate cartilage into normal cancellous bone by endochondral ossification.
NASA Astrophysics Data System (ADS)
Wang, Fang; Lu, Heng; Wang, Xu; Liu, Yufang
2018-03-01
Fiber-loop ring-down spectroscopy (FLRDS) technique can be used for measurement by indirectly measuring the ring-down time. This is advantageous because it is free from fluctuations of the light source and has a high sensitivity. A novel sensing system for measuring the concentration and temperature based on the FLRDS technique and Mach-Zehnder interferometer (MZI) is proposed in this work. The intra-cavity losses were compensated, which depended on the erbium-doped fiber amplifier. The sensor head was a section of 4 cm single-mode fiber that was spliced into the fiber loop ring cavity in a core-offset way, and its characteristics were tested by experimenting with different solution concentrations and temperatures. The experimental results showed that the detection limit of this system is 0.0014 g/ml, in the range of 0.010-0.400 g/ml. In the temperature sensing experiment, when the temperature varied from 30-200 °C, a sensitivity of 1.83 μs/°C was achieved. This research demonstrated that the MZI-based FLRDS sensing system has a clear response to the solution and temperature; therefore, it provides a reference for the measurement of stress, pressure, curvature, and other physical quantities.
Automatic multi-banking of memory for microprocessors
NASA Technical Reports Server (NTRS)
Wiker, G. A. (Inventor)
1984-01-01
A microprocessor system is provided with added memories to expand its address spaces beyond its address word length capacity by using indirect addressing instructions of a type having a detectable operations code and dedicating designated address spaces of memory to each of the added memories, one space to a memory. By decoding each operations code of instructions read from main memory into a decoder to identify indirect addressing instructions of the specified type, and then decoding the address that follows in a decoder to determine which added memory is associated therewith, the associated added memory is selectively enabled through a unit while the main memory is disabled to permit the instruction to be executed on the location to which the effective address of the indirect address instruction points, either before the indirect address is read from main memory or afterwards, depending on how the system is arranged by a switch.
Zheng, Xuefeng; Wu, Jiajia; Zhu, Yaofeng; Chen, Si; Chen, Zhi; Chen, Tao; Huang, Ziyun; Wei, Jiayou; Li, Yanmei; Lei, Wanlong
2018-04-16
Striatal-direct and -indirect Pathway Neurons showed different vulnerability in basal ganglia disorders. Therefore, present study aimed to examine and compare characteristic changes of densities, protein and mRNA levels of soma, dendrites, and spines between striatal-direct and -indirect pathway neurons after DA depletion by using immunohistochemistry, Western blotting, real-time PCR and immunoelectron microscopy techniques. Experimental results showed that: 1) 6OHDA-induced DA depletion decreased the soma density of striatal-direct pathway neurons (SP+), but no significant changes for striatal-indirect pathway neurons (ENK+). 2) DA depletion resulted in a decline of dendrite density for both striatal-direct (D1+) and -indirect (D2+) pathway neurons, and D2+ dendritic density declined more obviously. At the ultrastructure level, the densities of D1+ and D2+ dendritic spines reduced in the 6OHDA groups compared with their control groups, but the density of D2+ dendritic spines reduced more significant than that of D1. 3) Striatal DA depletion down-regulated protein and mRNA expression levels of SP and D1, on the contrary, ENK and D2 protein and mRNA levels of indirect pathway neurons were up-regulated significantly. Present results suggested that indirect pathway neurons be more sensitive to 6OHDA-induced DA depletion. Copyright © 2018 Elsevier Ltd. All rights reserved.
Sumbria, Deepak; Singla, L D; Kumar, Sanjay; Sharma, Amrita; Dahiya, Rajesh K; Setia, Raj
2016-03-01
Equine piroplasmosis is a febrile, tick-borne disease of equids predominately caused by obligatory intra-erythrocytic protozoa Theileria equi in the Indian sub-continent. A cross-sectional study was carried out on 464 equids (426 horses and 38 donkeys/mules) in Punjab, India to assess the level of exposure to equine piroplasmosis by 18S rRNA gene nested polymerase chain reaction (nPCR) and equine merozoite antigen-2 (EMA2) indirect-ELISA (enzyme linked immunosorbent assay), to investigate risk factors and haemato-biochemical alterations associated with the infection. The endemicity of the disease was confirmed by positive PCR amplification in 21.77% and positive antibody titers in 49.78% equid samples. There was a fair agreement between these two diagnostic techniques (Kappa coefficient=0.326). The spatial distribution analysis revealed an increasing trend of T. equi prevalence from north-eastern to south-western region of Punjab by both the techniques correspondingly, which proffered a direct relation with temperature and inverse with humidity variables. The relatively prominent risk factor associated with sero-positivity was the presence of other domestic animals in the herd, while the propensity of finding a positive PCR amplification was higher in donkeys/mules, animal kept at unorganised farm or those used for commercial purposes as compared to their counterparts. There was a significant increase in globulins, gamma glutamyl-transferase, total bilirubin, direct bilirubin, indirect bilirubin, glucose levels and decrease in total erythrocyte count, haemoglobin, packed cell volume by animals, which were revealed positive by nPCR (may or may not positive by indirect-ELISA) and increase in creatinine, total bilirubin, direct bilirubin, glucose and decrease in total erythrocytes count by animals, which were revealed positive by indirect-ELISA (alone). To our knowledge, this study, for the first time, brings out a comprehensive report on the status on spatial distribution of T. equi in Punjab (India) state, thoroughly investigated by molecular and serological techniques, evaluating various environmental and demographic risk factors along with the haemato-biochemical alterations in the exposed animals. Copyright © 2015 Elsevier B.V. All rights reserved.
Walraph, J; Zoche-Golob, V; Weber, J; Freick, M
2018-06-01
In cattle, indirect enzyme-linked immunosorbent assay (ELISA) tests are commonly used in serological routine diagnostics. In a longitudinal study design, changes in relative optical density (OD) from drying-off until week 11 after calving were analyzed in blood and milk samples from pluriparous dairy cows (n=21) using a commercial indirect anti-C. burnetii ELISA test. In a second part of this study, changes over time were evaluated in blood and milk samples of 11 of these cows in an indirect ELISA detecting anti-Bovine viral diarrhea virus (BVDV) antibodies. Regarding the cows which were still in the herd at the time of calving, blood serological qualitative changes from positive to negative or indeterminate were demonstrated in 7/20 cows (35%) for the anti-C. burnetii indirect ELISA and in 2/10 cows (20%) for the anti-BVDV indirect ELISA, respectively, during the period from 14days ante partum to calving. Relative OD in the anti-C. burnetii and the anti-BVDV indirect ELISA tests followed basically similar courses over time. In blood serum, relative OD initially increased after drying-off, before a drop around calving was observed. After the colostrum period, relative OD in blood serum showed an increase until week 11 of lactation. In colostrum samples, relative OD levels were higher than in milk samples obtained one day before drying-off. After parturition, relative OD in milk decreased until week 6 of lactation in the anti-C. burnetii indirect ELISA and until week 11 in the anti-BVDV indirect ELISA, respectively. In conclusion, blood serological investigations in periparturient dairy cows using indirect ELISA kits should be avoided. Copyright © 2018 Elsevier Ltd. All rights reserved.
SERS-based application in food analytics (Conference Presentation)
NASA Astrophysics Data System (ADS)
Cialla-May, Dana; Radu, Andreea; Jahn, Martin; Weber, Karina; Popp, Jürgen
2017-02-01
To establish detection schemes in life science applications, specific and sensitive methods allowing for fast detection times are required. Due to the interaction of molecules with strong electromagnetic fields excited at metallic nanostructures, the molecular fingerprint specific Raman spectrum is increased by several orders of magnitude. This effect is described as surface-enhanced Raman spectroscopy (SERS) and became a very powerful analytical tool in many fields of application. Within this presentation, we will introduce innovative bottom-up strategies to prepare SERS-active nanostructures coated with a lipophilic sensor layer. To do so, the food colorant Sudan III, an indirect carcinogen substance found in chili powder, palm oil or spice mixtures, is detected quantitatively in the background of the competitor riboflavin as well as paprika powder extracts. The SERS-based detection of azorubine (E122) in commercial available beverages with different complexity (e.g. sugar content, alcohol concentration) illustrates the strong potential of SERS as a qualitative as well as semiquantitative prescan method in food analytics. Here, a good agreement between the estimated concentration employing SERS as well as the gold standard technique HPLC, a highly laborious method, is found. Finally, SERS is applied to detect vitamin B2 and B12 in cereals as well as the estimate the ratio of lycopene and β-carotene in tomatoes. Acknowledgement: Funding the projects "QuantiSERS" and "Jenaer Biochip Initiative 2.0" within the framework "InnoProfile Transfer - Unternehmen Region" the Federal Ministry of Education and Research, Germany (BMBF) is gratefully acknowledged.
[Development and application of CK-MB specific monoclonal antibodies].
Chen, Zimin; Zhou, Guoliang; Xu, Weiling; Zheng, Xiaohong; Tong, Xunzhang; Ke, Qishen; Song, Liuwei; Ge, Shengxiang
2017-01-25
The aim of this study is to develop creatine kinase isoenzyme MB (CK-MB) specific monoclonal antibodies (mAb), and characterize the monoclonal antibody and further development of quantitative detection assay for CK-MB. The BALB/c mice were immunized with purchased CK-MB antigen, then monoclonal antibodies were prepared according to conventional hybridoma technique and screened by indirect and capture ELISA method. To identify the epitopes and evaluate the classification, purchased creatine kinase isoenzyme MB (CK-MM/BB/MB) antigen was used to identify the epitopes, with immunoblotting and synthetic CK-MM and CK-BB in different linear epitope. A double antibody sandwich ELISA was applied to screen the mAb pairs for CK-MB detection, and the quantitative detection assay for CK-MB was developed. We used 74 cases of clinical specimens for comparison of our assay with Roche's CK-MB assay. We successfully developed 22 strains of hybridoms against CK-MB, these mAbs can be divided into linear, partial conformational CK-MB, CK-MM or CK-BB cross monoclonal antibody and CK-MB specific reaction with partial conformational monoclonal antibody, and CK-MB quantitative detection assay was developed by using partial conformational monoclonal antibody. The correlation coefficient factor r of our reagent and Roche's was 0.930 9. This study established a screening method for CK-MB partial conformational specific monoclonal antibody, and these monoclonal antibodies were analyzed and an established quantitative detection assay was developed. The new assay had a high concordance with Roche's.
How good are indirect tests at detecting recombination in human mtDNA?
White, Daniel James; Bryant, David; Gemmell, Neil John
2013-07-08
Empirical proof of human mitochondrial DNA (mtDNA) recombination in somatic tissues was obtained in 2004; however, a lack of irrefutable evidence exists for recombination in human mtDNA at the population level. Our inability to demonstrate convincingly a signal of recombination in population data sets of human mtDNA sequence may be due, in part, to the ineffectiveness of current indirect tests. Previously, we tested some well-established indirect tests of recombination (linkage disequilibrium vs. distance using D' and r(2), Homoplasy Test, Pairwise Homoplasy Index, Neighborhood Similarity Score, and Max χ(2)) on sequence data derived from the only empirically confirmed case of human mtDNA recombination thus far and demonstrated that some methods were unable to detect recombination. Here, we assess the performance of these six well-established tests and explore what characteristics specific to human mtDNA sequence may affect their efficacy by simulating sequence under various parameters with levels of recombination (ρ) that vary around an empirically derived estimate for human mtDNA (population parameter ρ = 5.492). No test performed infallibly under any of our scenarios, and error rates varied across tests, whereas detection rates increased substantially with ρ values > 5.492. Under a model of evolution that incorporates parameters specific to human mtDNA, including rate heterogeneity, population expansion, and ρ = 5.492, successful detection rates are limited to a range of 7-70% across tests with an acceptable level of false-positive results: the neighborhood similarity score incompatibility test performed best overall under these parameters. Population growth seems to have the greatest impact on recombination detection probabilities across all models tested, likely due to its impact on sequence diversity. The implications of our findings on our current understanding of mtDNA recombination in humans are discussed.
How Good Are Indirect Tests at Detecting Recombination in Human mtDNA?
White, Daniel James; Bryant, David; Gemmell, Neil John
2013-01-01
Empirical proof of human mitochondrial DNA (mtDNA) recombination in somatic tissues was obtained in 2004; however, a lack of irrefutable evidence exists for recombination in human mtDNA at the population level. Our inability to demonstrate convincingly a signal of recombination in population data sets of human mtDNA sequence may be due, in part, to the ineffectiveness of current indirect tests. Previously, we tested some well-established indirect tests of recombination (linkage disequilibrium vs. distance using D′ and r2, Homoplasy Test, Pairwise Homoplasy Index, Neighborhood Similarity Score, and Max χ2) on sequence data derived from the only empirically confirmed case of human mtDNA recombination thus far and demonstrated that some methods were unable to detect recombination. Here, we assess the performance of these six well-established tests and explore what characteristics specific to human mtDNA sequence may affect their efficacy by simulating sequence under various parameters with levels of recombination (ρ) that vary around an empirically derived estimate for human mtDNA (population parameter ρ = 5.492). No test performed infallibly under any of our scenarios, and error rates varied across tests, whereas detection rates increased substantially with ρ values > 5.492. Under a model of evolution that incorporates parameters specific to human mtDNA, including rate heterogeneity, population expansion, and ρ = 5.492, successful detection rates are limited to a range of 7−70% across tests with an acceptable level of false-positive results: the neighborhood similarity score incompatibility test performed best overall under these parameters. Population growth seems to have the greatest impact on recombination detection probabilities across all models tested, likely due to its impact on sequence diversity. The implications of our findings on our current understanding of mtDNA recombination in humans are discussed. PMID:23665874
Bu, Ri-E; Wang, Jin-Liang; Wu, Jin-Hua; Xilin, Gao-Wa; Chen, Jin-Long; Wang, Hua
2017-03-01
The aim of this study was to establish a rapid and accurate method for the detection of the Streptococcus agalactiae antibody (SA-Ab) to determine the presence of the bovine mastitis (BM)-causative pathogen. The multi-subunit fusion protein rSip-Pgk-FbsA was prokaryotically expressed and purified. The triple activities of the membrane surface-associated proteins Sip, phosphoglycerate kinase (Pgk), and fibronectin (FbsA) were used as the diagnostic antigens to establish an indirect enzyme-linked immunosorbent assay (ELISA) method for the detection of SA-Ab in BM. The optimal antigen coating concentration was 2 μg/mL, the optimal serum dilution was 1:160, and the optimal dilution of the enzyme-labeled secondary antibody was 1:6000. The sensitivity, specificity, and repeatability tests showed that the method established in this study had no cross-reaction with antibodies to Streptococcus pyogenes, Escherichia coli, Staphylococcus aureus, and Staphylococcus epidermidis in the sera. The results of the sensitivity test showed that a positive result could be obtained even if the serum dilution reached 1:12,800, indicating the high sensitivity and good repeatability of the method. The positive coincidence rate of this method was 98.6%, which is higher than that of previous tests established with the Sip or Pgk mono-antigen fusion protein, respectively, demonstrating the relatively higher sensitivity of this newly established method. The detection rate for 389 clinical samples was 46.53%. The indirect ELISA method established in this study could provide a more accurate and reliable serological method for the rapid detection of S. agalactiae in cases of BM.
USDA-ARS?s Scientific Manuscript database
An indirect ELISA was developed using baculovirus expressed N1 protein from the A/chicken/Indonesia/7/2003 (H5N1) virus. The specificity of the assay was tested with a panel of chicken antisera raised against N1 to N9 virus subtypes. The N1-ELISA was specific for the detection of N1 antibodies in ...
Hirve, Siddhivinayak; Vounatsou, Penelope; Juvekar, Sanjay; Blomstedt, Yulia; Wall, Stig; Chatterji, Somnath; Ng, Nawi
2014-03-01
We compared prevalence estimates of self-rated health (SRH) derived indirectly using four different small area estimation methods for the Vadu (small) area from the national Study on Global AGEing (SAGE) survey with estimates derived directly from the Vadu SAGE survey. The indirect synthetic estimate for Vadu was 24% whereas the model based estimates were 45.6% and 45.7% with smaller prediction errors and comparable to the direct survey estimate of 50%. The model based techniques were better suited to estimate the prevalence of SRH than the indirect synthetic method. We conclude that a simplified mixed effects regression model can produce valid small area estimates of SRH. © 2013 Published by Elsevier Ltd.
Zhang, Chaoting; Liu, Ying; Gao, Weijiao; Pan, Yaqi; Gao, Yunong; Shen, Jing; Xiong, Hongchao
2018-05-01
Cervical microbiota composition is associated with cervical HPV infection and CIN severity. Previous studies only assessed the total association between cervical microbiota and HPV infections or CINs, and yet no study reported the direct and indirect associations between cervical microbiota and CINs mediated by HPV infection, respectively. The aim of this study was to investigate the direct and indirect associations between microbiotas and CIN severity. Cervical microbiota of 126 women with CIN 1- (normal cytology and CIN 1) and 40 with CIN 2+ (CIN 2 and CIN 3) were analyzed using Illumina sequencing based on the 16S rRNA gene. HPV was detected using a highly sensitive PCR primer set (SPF1/GP6+). Indirect effects of Pseudomonas stutzeri, Bacteroides fragilis, Lactobacillus delbrueckii, Atopobium vaginae, and Streptococcus agalactiae mediated by HPV infection on CIN status were observed. The directions of the direct and the indirect associations between CIN status and Ps. stutzeri were opposite. The directions of the direct and the indirect associations between CIN status and A. vaginae were the same. B. fragilis, L. delbrueckii, and S. agalactiae only had indirect association with CIN status. In summary, our study provided suggestive evidence that some microbial populations could have direct or indirect effects mediated by affecting HPV infection on CIN progression. Besides HPV infection, microbial community composition possibly plays a role in cervical carcinogenesis. © 2018 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
Nawabi, Danyal H.; Imhauser, Carl; Tucker, Scott; Nguyen, Joseph; Wickiewicz, Thomas L.; Pearle, Andrew
2014-01-01
Objectives: Histological studies have shown that the ACL has a direct and indirect insertion on the femur [1]. The direct insertion is located along the lateral intercondylar ridge and the indirect insertion is located ‘lower’ on the lateral wall of the notch. The trend towards anatomic ACL reconstruction using the anteromedial (AM) portal technique has resulted in ‘lower’ non-isometric femoral tunnel positions and increased graft failures [2]. To our knowledge, the load transfer properties of the direct and indirect ACL insertions have not been studied. This information may help in understanding the increased failures reported with AM portal drilling. The purpose of this study was, 1) to compare the load transferred across the native ACL at the direct and indirect femoral insertions and, 2) to determine the strain behavior of ACL grafts placed at different tunnel locations within the direct and indirect insertions. Methods: Ten fresh-frozen cadaveric knees (mean age, 52.5 years; range, 29-65) were mounted to a six degree of freedom robot. A 134N anterior load at 30 and 90° flexion and a combined valgus (8Nm) and internal (4Nm) rotational moment at 15° flexion were applied. The ACL was subsequently sectioned at the femoral footprint by detaching either the direct or indirect insertion (partially sectioned state), followed by the remainder of the ACL (completely sectioned state) (Figure 1). The kinematics of the intact knee were replayed after each stage of sectioning to determine the loads transferred across the direct and indirect ACL fibers. Loads were expressed as a percentage of the total load borne by the ACL. Strain behaviour was tested by generating 3D models of the femur and tibia from CT scans of each knee. Three tunnel locations (anteromedial bundle [AM], center [C], posterolateral bundle [PL]) each were selected for the direct and indirect insertions and a virtual ACL graft was inserted. The isometry of the virtual graft was calculated through a flexion path of 0 to 90°. Results: Under an anterior tibial load at 30° flexion, the direct insertion carried 83.9% of the total ACL load compared to 16.1% in the indirect insertion (p<0.001). The direct insertion also carried more load at 90° flexion (95.2% vs 4.8%; p<0.001). Under a combined rotatory load at 15° flexion, the direct insertion carried 84.2% of the total ACL load compared to 15.8% in the indirect insertion (p<0.001). A virtual ACL graft placed at the AM position in the direct insertion demonstrated the best strain behaviour with a mean 10.9% change in length. This value was significantly lower (p<0.001) than the isometry at all 3 tunnel positions in the indirect insertion (AM = 18.5%; C = 24.9%; PL = 30.9%). Conclusion: Fibers in the direct insertion of the ACL carry more load than fibers in the indirect insertion. Virtual ACL grafts placed in the ‘higher’ direct location are more isometric than in the ‘lower’ indirect location during range of motion testing. Clinical Relevance: ‘Low’ ACL grafts in the indirect ACL insertion, resulting from AM portal drilling techniques, may experience higher loads in-vivo due to unfavorable biomechanics. With the current shift towards anatomic ACL reconstruction, it may be beneficial to create a ‘higher’ femoral tunnel within the direct insertion at the lateral intercondylar ridge. This position remains anatomical but may also be biomechanically favorable.
Nonmydriatic fluorescence-based quantitative imaging of human macular pigment distributions
NASA Astrophysics Data System (ADS)
Sharifzadeh, Mohsen; Bernstein, Paul S.; Gellermann, Werner
2006-10-01
We have developed a CCD-camera-based nonmydriatic instrument that detects fluorescence from retinal lipofuscin chromophores ("autofluorescence") as a means to indirectly quantify and spatially image the distribution of macular pigment (MP). The lipofuscin fluorescence intensity is reduced at all retinal locations containing MP, since MP has a competing absorption in the blue-green wavelength region. Projecting a large diameter, 488 nm excitation spot onto the retina, centered on the fovea, but extending into the macular periphery, and comparing lipofuscin fluorescence intensities outside and inside the foveal area, it is possible to spatially map out the distribution of MP. Spectrally selective detection of the lipofuscin fluorescence reveals an important wavelength dependence of the obtainable image contrast and deduced MP optical density levels, showing that it is important to block out interfering fluorescence contributions in the detection setup originating from ocular media such as the lens. Measuring 70 healthy human volunteer subjects with no ocular pathologies, we find widely varying spatial extent of MP, distinctly differing distribution patterns of MP, and strongly differing absolute MP levels among individuals. Our population study suggests that MP imaging based on lipofuscin fluorescence is useful as a relatively simple, objective, and quantitative noninvasive optical technique suitable to rapidly screen MP levels and distributions in healthy humans with undilated pupils.
Zhang, Yeping; Zhu, Ping; Shi, Yongjin; Liu, Jihua; Pu, Dingfang; Cao, Xianghong; Zhu, Qiang; Wang, Yijia; Ma, Mingxin; Yu, Jiren
2002-02-01
To investigate the anti-human CEM lymphoma cell activities induced by TCR idiotypic DNA vaccine containing different antigen determinants in BALB/c mice. The specific rearranged gene fragment encoding TCRVbeta region of CEM cell line was obtained by RT-PCR technique. The PCR product was cloned into eukaryocytic expression vector pcDNA3, which was used as DNA vaccine and template for PCR amplifying different antigen determinant. Gene fragments encoding different antigen determinant were amplified and cloned into pcDNA3, separately. The experimental mice were immunized by intramuscular injection of the DNA vaccines. The specific anti-idiotype antibodies were detected by indirect immunofluorescence assay. TCRbetaV of CEM cell line contains five antigen determinants. Specific anti-idiotype antibody was detected in all of the six mice immunized with DNA vaccine containing all the five determinants (the highest titer was 1:480). Although the antibody could also be detected in four of the six mice immunized with DNA vaccine containing four of the five antigen determinants, the antibody titer was lower (the highest titer was 1:80). DNA vaccine containing two of the five determinants could not induce the specific antibody. The idiotypic DNA vaccine containing the whole TCRbetaV five antigen determinants could induce the specific anti-lymphoma idiotypic antibody in BALB/c mice.
Indirect myosin immunocytochemistry for the identification of fibre types in equine skeletal muscle
NASA Technical Reports Server (NTRS)
Sinha, A. K.; Rose, R. J.; Pozgaj, I.; Hoh, J. F.
1992-01-01
The histochemical ATPase method for muscle fibre typing was first described by Brooke and Kaiser in 1970. However, problems have been found with the subdivision of type II fibres using this technique. To determine whether indirect myosin immunocytochemistry using anti-slow (5-4D), anti-fast (1A10) and anti-fast red (5-2B) monoclonal antibodies with cross reactivity for type I, II and IIa fibres, respectively, in a number of species, could identify three fibre types in equine skeletal muscle, data on fibre type composition and fibre size obtained using the two different techniques were compared. Results indicate that different myosin heavy chains can coexist in single equine muscle fibres. Type I and type II fibres were identified by immunocytochemistry, but subdivision of type II fibres was not possible. Although the percentage of type I and type II fibres was not significantly different for the two techniques, a few fibres reacted with both the 1A10 and 5-4D antibodies.
An adaptive optics search for young extrasolar planets
NASA Astrophysics Data System (ADS)
Macintosh, B.; Zuckerman, B.; Becklin, E. E.; Kaisler, D.; Lowrance, P.; Max, C. E.; Olivier, S.
2000-10-01
In the past five years, many extrasolar planets have been detected indirectly, through radial velocity variations induced in their parent stars. Advances in technology now open up the possibility of directly detecting extrasolar planets through the photons they emit. Direct detection would allow determination of the temperature, radius, and composition of a planet, particularly one in a wide orbit - an important complement to radial velocity techniques. Seeing a planet against the halo of scattered light from its parent star is extremely challenging, but adaptive optics (AO) on 8-10 m telescopes can make this possible. The first such large-telescope AO system is now operational on the 10-m W.M. Keck II telescope. Its current performance is sufficient to detect objects at contrast ratios of 105 at separations of 1" and 106 at 2". This is insufficient to detect the reflected light from a mature Jupiter-like planet, but we can easily detect the near-infrared thermal emission from young (<10-50 MYr) planets, or older brown dwarfs. We are carrying out a search for such planetary companions to young nearby stars, including the TW Hydrae association. We present preliminary results from this survey, including sensitivity limits and follow-up of candidate companions originally detected by NICMOS. We have also imaged the Epsilon Eridani system, and present upper limits on the brightness of the planet detected via radial velocity variations by Cochran et al. This research was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract W-7405-ENG-48, and also supported in part by the Center for Adaptive Optics under the STC Program of the National Science Foundation under Agreement No. AST-9876783
Li, Pingjing; Hu, Bin; Li, Xiaoyong
2012-07-20
In this study, a sensitive, selective and reliable analytical method by combining zirconia (ZrO₂) coated stir bar sorptive extraction (SBSE) with large volume sample stacking capillary electrophoresis-indirect ultraviolet (LVSS-CE/indirect UV) was developed for the direct analysis of chemical warfare agent degradation products of alkyl alkylphosphonic acids (AAPAs) (including ethyl methylphosphonic acid (EMPA) and pinacolyl methylphosphonate (PMPA)) and methylphosphonic acid (MPA) in environmental waters. ZrO₂ coated stir bar was prepared by adhering nanometer-sized ZrO₂ particles onto the surface of stir bar with commercial PDMS sol as adhesion agent. Due to the high affinity of ZrO₂ to the electronegative phosphonate group, ZrO₂ coated stir bars could selectively extract the strongly polar AAPAs and MPA. After systematically optimizing the extraction conditions of ZrO₂-SBSE, the analytical performance of ZrO₂-SBSE-CE/indirect UV and ZrO₂-SBSE-LVSS-CE/indirect UV was assessed. The limits of detection (LODs, at a signal-to-noise ratio of 3) obtained by ZrO₂-SBSE-CE/indirect UV were 13.4-15.9 μg/L for PMPA, EMPA and MPA. The relative standard deviations (RSDs, n=7, c=200 μg/L) of the corrected peak area for the target analytes were in the range of 6.4-8.8%. Enhancement factors (EFs) in terms of LODs were found to be from 112- to 145-fold. By combining ZrO₂ coating SBSE with LVSS as a dual preconcentration strategy, the EFs were magnified up to 1583-fold, and the LODs of ZrO₂-SBSE-LVSS-CE/indirect UV were 1.4, 1.2 and 3.1 μg/L for PMPA, EMPA, and MPA, respectively. The RSDs (n=7, c=20 μg/L) were found to be in the range of 9.0-11.8%. The developed ZrO₂-SBSE-LVSS-CE/indirect UV method has been successfully applied to the analysis of PMPA, EMPA, and MPA in different environmental water samples, and the recoveries for the spiked water samples were found to be in the range of 93.8-105.3%. Copyright © 2012 Elsevier B.V. All rights reserved.
Manokawinchoke, Jeeranan; Nattasit, Praphawi; Thongngam, Tanutchaporn; Pavasant, Prasit; Tompkins, Kevin A; Egusa, Hiroshi; Osathanon, Thanaphum
2017-08-31
Notch signaling regulates diverse biological processes in dental pulp tissue. The present study investigated the response of human dental pulp cells (hDPs) to the indirect immobilized Notch ligand Jagged1 in vitro. The indirect immobilized Jagged1 effectively activated Notch signaling in hDPs as confirmed by the upregulation of HES1 and HEY1 expression. Differential gene expression profiling using an RNA sequencing technique revealed that the indirect immobilized Jagged1 upregulated genes were mainly involved in extracellular matrix organization, disease, and signal transduction. Downregulated genes predominantly participated in the cell cycle, DNA replication, and DNA repair. Indirect immobilized Jagged1 significantly reduced cell proliferation, colony forming unit ability, and the number of cells in S phase. Jagged1 treated hDPs exhibited significantly higher ALP enzymatic activity, osteogenic marker gene expression, and mineralization compared with control. Pretreatment with a γ-secretase inhibitor attenuated the Jagged1-induced ALP activity and mineral deposition. NOTCH2 shRNA reduced the Jagged1-induced osteogenic marker gene expression, ALP enzymatic activity, and mineral deposition. In conclusion, indirect immobilized Jagged1 suppresses cell cycle progression and induces the odonto/osteogenic differentiation of hDPs via the canonical Notch signaling pathway.
3D X-ray ultra-microscopy of bone tissue.
Langer, M; Peyrin, F
2016-02-01
We review the current X-ray techniques with 3D imaging capability at the nano-scale: transmission X-ray microscopy, ptychography and in-line phase nano-tomography. We further review the different ultra-structural features that have so far been resolved: the lacuno-canalicular network, collagen orientation, nano-scale mineralization and their use as basis for mechanical simulations. X-ray computed tomography at the micro-metric scale is increasingly considered as the reference technique in imaging of bone micro-structure. The trend has been to push towards increasingly higher resolution. Due to the difficulty of realizing optics in the hard X-ray regime, the magnification has mainly been due to the use of visible light optics and indirect detection of the X-rays, which limits the attainable resolution with respect to the wavelength of the visible light used in detection. Recent developments in X-ray optics and instrumentation have allowed to implement several types of methods that achieve imaging that is limited in resolution by the X-ray wavelength, thus enabling computed tomography at the nano-scale. We review here the X-ray techniques with 3D imaging capability at the nano-scale: transmission X-ray microscopy, ptychography and in-line phase nano-tomography. Further, we review the different ultra-structural features that have so far been resolved and the applications that have been reported: imaging of the lacuno-canalicular network, direct analysis of collagen orientation, analysis of mineralization on the nano-scale and use of 3D images at the nano-scale to drive mechanical simulations. Finally, we discuss the issue of going beyond qualitative description to quantification of ultra-structural features.
Noninvasive Fetal Electrocardiography Part II: Segmented-Beat Modulation Method for Signal Denoising
Agostinelli, Angela; Sbrollini, Agnese; Burattini, Luca; Fioretti, Sandro; Di Nardo, Francesco; Burattini, Laura
2017-01-01
Background: Fetal well-being evaluation may be accomplished by monitoring cardiac activity through fetal electrocardiography. Direct fetal electrocardiography (acquired through scalp electrodes) is the gold standard but its invasiveness limits its clinical applicability. Instead, clinical use of indirect fetal electrocardiography (acquired through abdominal electrodes) is limited by its poor signal quality. Objective: Aim of this study was to evaluate the suitability of the Segmented-Beat Modulation Method to denoise indirect fetal electrocardiograms in order to achieve a signal-quality at least comparable to the direct ones. Method: Direct and indirect recordings, simultaneously acquired from 5 pregnant women during labor, were filtered with the Segmented-Beat Modulation Method and correlated in order to assess their morphological correspondence. Signal-to-noise ratio was used to quantify their quality. Results: Amplitude was higher in direct than indirect fetal electrocardiograms (median:104 µV vs. 22 µV; P=7.66·10-4), whereas noise was comparable (median:70 µV vs. 49 µV, P=0.45). Moreover, fetal electrocardiogram amplitude was significantly higher than affecting noise in direct recording (P=3.17·10-2) and significantly in indirect recording (P=1.90·10-3). Consequently, signal-to-noise ratio was initially higher for direct than indirect recordings (median:3.3 dB vs. -2.3 dB; P=3.90·10-3), but became lower after denoising of indirect ones (median:9.6 dB; P=9.84·10-4). Eventually, direct and indirect recordings were highly correlated (median: ρ=0.78; P<10-208), indicating that the two electrocardiograms were morphologically equivalent. Conclusion: Segmented-Beat Modulation Method is particularly useful for denoising of indirect fetal electrocardiogram and may contribute to the spread of this noninvasive technique in the clinical practice. PMID:28567129
Vazquez Boucard, Celia; Lee-Cruz, Larisa; Mercier, Laurence; Ramírez Orozco, Martín; Serrano Pinto, Vania; Anguiano, Gerardo; Cazares, Linette; Díaz, Daniel
2017-10-01
Because of concerns that natural aquifers in the region of Todos Santos (Baja California Sur, Mexico) might be contaminated by organochlorine pesticides and heavy metals, a case-control study was conducted among consumers and non-consumers of well- and/or tap-water to determine risks to human health. This study was based on a genotoxic evaluation of buccal cells using the Comet assay technique. Levels of DNA damage in the consumers group were significantly higher than those of the control group. However, occupational exposure to genotoxicants showed to be the critical factor rather than water consumption. Taking into account the professions of well- and/or tap-water consumers, agricultural workers exposed directly (those who fumigated) or indirectly (those not involved in fumigating) to agrochemicals showed greater genetic damage than controls. This difference persisted even when age, and whether the person smoked or consumed alcoholic drinks were considered. These factors were not associated with the level of genetic damage observed. Chemical analyses of organochlorine pesticides and heavy metals were carried out to evaluate the water quality of wells, faucets, and surface water of canals consumed by the population and/or used for irrigation. High concentrations of α and β endosulfan were detected in water of surface canals. Although our inventory of agrochemicals employed in the region showed the use of products considered carcinogenic and/or mutagenic, they were not detected by the analytical techniques used. Heavy metals (arsenic, mercury, and lead) were detected in water of some wells used for irrigation and human consumption. Environ. Mol. Mutagen. 58:619-627, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Mehrmohammadi, Mohammad; Ma, Li L.; Chen, Yun-Sheng; Qu, Min; Joshi, Pratixa; Chen, Raeanna M.; Johnston, Keith P.; Emelianov, Stanislav
2010-02-01
Photothermal therapy is a laser-based non-invasive technique for cancer treatment. Photothermal therapy can be enhanced by employing metal nanoparticles that absorb the radiant energy from the laser leading to localized thermal damages. Targeting of nanoparticles leads to more efficient uptake and localization of photoabsorbers thus increasing the effectiveness of the treatment. Moreover, efficient targeting can reduce the required dosage of photoabsorbers; thereby reducing the side effects associated with general systematic administration of nanoparticles. Magnetic nanoparticles, due to their small size and response to an external magnetic field gradient have been proposed for targeted drug delivery. In this study, we investigate the applicability of multifunctional nanoparticles (e.g., magneto-plasmonic nanoparticles) and magneto-motive ultrasound imaging for image-guided photothermal therapy. Magneto-motive ultrasound imaging is an ultrasound based imaging technique capable of detecting magnetic nanoparticles indirectly by utilizing a high strength magnetic field to induce motion within the magnetically labeled tissue. The ultrasound imaging is used to detect the internal tissue motion. Due to presence of the magnetic component, the proposed multifunctional nanoparticles along with magneto-motive ultrasound imaging can be used to detect the presence of the photo absorbers. Clearly the higher concentration of magnetic carriers leads to a monotonic increase in magneto-motive ultrasound signal. Thus, magnetomotive ultrasound can determine the presence of the hybrid agents and provide information about their location and concentration. Furthermore, the magneto-motive ultrasound signal can indicate the change in tissue elasticity - a parameter that is expected to change significantly during the photothermal therapy. Therefore, a comprehensive guidance and assessment of the photothermal therapy may be feasible through magneto-motive ultrasound imaging and magnetoplasmonic nanoparticles.
Wang, Weiping; Tang, Jianghong; Wang, Shumin; Zhou, Lei; Hu, Zhide
2007-04-27
A capillary zone electrophoresis (CZE) with indirect laser-induced fluorescence detection (ILIFD) method is described for the simultaneous determination of esculin, esculetin, isofraxidin, genistein, naringin and sophoricoside. The baseline separation was achieved within 5 min with running buffer (pH 9.4) composed of 5mM borate, 20% methanol (v/v) as organic modifier, 10(-7)M fluorescein sodium as background fluorophore and 20 kV of applied voltage at 30 degrees C of cartridge temperature. Good linearity relationships (correlation coefficients >0.9900) between the second-order derivative peak-heights (RFU) and concentrations of the analytes (mol L(-1)) were obtained. The detection limits for all analytes in second-order derivative electrophoregrams were in the range of 3.8-15 microM. The RSD data of intra-day for migration times and second-order derivative peak-height were less than 0.95 and 5.02%, respectively. This developed method was applied to the analysis of the courmin compounds in herb plants with recoveries in the range of 94.7-102.1%. In this work, although the detection sensitivity was lower than that of direct LIF, yet the method would extend the application range of LIF detection.
Zhang, Yuyao; Ma, Xiuli; Huang, Bing; Li, Yufeng; Yu, Kexiang; Li, Jianliang; Liu, Cunxia; Han, Hongyu; Cui, Yanshun
2015-04-04
To simultaneously detect antibodies against Duck hepatitis A type 1 (DHAV-1) and type 3 (DHAV-3) viruses, we developed an indirect enzyme-linked immunosobent assay (ELISA) with bacterially expressed recombinant viral protein as antigen in Escherichia coli. We amplified the full-length VP3 gene of DHAV-1 and the full-length VP1 gene of DHAV-3 through reverse transcription-polymerase chain reaction (RT-PCR) and then cloned them into pET-32a expression vector, designated as pET-1VP3-3VP1. The fusion protein DHAV-1VP3-3VP1 expressed correctly and was subsequently used to develop an indirect ELISA assay. DHAV-1VP3-3VP1 fusion protein expressed in BL21 (DE3) cells following induction by Isopropyl-beta-D-1-thiogalactopyranoside (IPTG). The expressed protein was very antigenic and reactive to virus-specific antibodies in western blot assay. The optimal working concentration for coating antigen was 1.0 microg per well and the working concentration of serum samples was 1:200 dilution and the cut-off value that distinguished the positive from negative serum samples was OD650 > OR = 0.38. The ELISA method based on the prokaryotic expression of VP3 (DHAV-1) and VP1 proteins (DHAV-3) can be used effectively for the clinical detection antibodies against DHAV-1 and DHAV-3.
Merli, Marco; Galli, Laura; Castagna, Antonella; Salpietro, Stefania; Gianotti, Nicola; Messina, Emanuela; Poli, Andrea; Morsica, Giulia; Bagaglio, Sabrina; Cernuschi, Massimo; Bigoloni, Alba; Uberti-Foppa, Caterina; Lazzarin, Adriano; Hasson, Hamid
2016-04-01
We determined the diagnostic accuracy and optimal cut off of three indirect fibrosis biomarkers (APRI, FIB-4, Forns) compared with liver stiffness (LS) for the detection of liver cirrhosis in HIV/HCV-coinfected patients. An observational retrospective study on HIV/HCV-coinfected patients with concomitant LS measurement and APRI, FIB-4 and Forns was performed. The presence of liver cirrhosis was defined as a LS ≥13 KPa. The diagnostic accuracy and optimal cut-off values, compared with LS categorization (<13 vs ≥13 KPa), were determined by receiver operating characteristics (ROC) curves. The study sample included 646 patients. The area-under-the ROC curve (95% confidence interval) for the detection of liver cirrhosis were 0.84 (0.81-0.88), 0.87 (0.84-0.91) and 0.87 (0.84-0.90) for APRI, FIB-4 and Forns, respectively. According to the optimal cut off values for liver cirrhosis (≥0.97 for APRI, ≥2.02 for FIB-4 and ≥7.8 for Forns), 80%, 80% and 82% of subjects were correctly classified by the three indirect fibrosis biomarkers, respectively. Misclassifications were mostly due to false positive cases. The study suggests that indirect fibrosis biomarkers can help clinicians to exclude liver cirrhosis in the management of HIV/HCV co-infected patients, reducing the frequency of more expensive or invasive assessments.
Indirect Charged Particle Detection: Concepts and a Classroom Demonstration
ERIC Educational Resources Information Center
Childs, Nicholas B.; Horányi, Mihály; Collette, Andrew
2013-01-01
We describe the principles of macroscopic charged particle detection in the laboratory and their connections to concepts taught in the physics classroom. Electrostatic dust accelerator systems, capable of launching charged dust grains at hypervelocities (1-100 km/s), are a critical tool for space exploration. Dust grains in space typically have…
Huang, Yi; Zhu, Youjie; Yang, Mengshi; Zhang, Zhenqing; Song, Donglin; Yuan, Zhiming
2014-12-01
Full-length nucleoproteins from Ebola and Marburg viruses were expressed as His-tagged recombinant proteins in Escherichia coli and nucleoprotein-based enzyme-linked immunosorbent assays (ELISAs) were established for the detection of antibodies specific to Ebola and Marburg viruses. The ELISAs were evaluated by testing antisera collected from rabbit immunized with Ebola and Marburg virus nucleoproteins. Although little cross-reactivity of antibodies was observed in anti-Ebola virus nucleoprotein rabbit antisera, the highest reactions to immunoglobulin G (IgG) were uniformly detected against the nucleoprotein antigens of homologous viruses. We further evaluated the ELISA's ability to detect antibodies to Ebola and Marburg viruses using human sera samples collected from individuals passing through the Guangdong port of entry. With a threshold set at the mean plus three standard deviations of average optical densities of sera tested, the ELISA systems using these two recombinant nucleoproteins have good sensitivity and specificity. These results demonstrate the usefulness of ELISA for diagnostics as well as ecological and serosurvey studies of Ebola and Marburg virus infection.
Goodman, Alice E; Carmichael, Daniel T
2016-03-01
Maxillofacial trauma in cats often results in mandibular symphyseal separation in addition to injuries of the caudal mandible and/or temporomandibular joint (TMJ). Caudal mandibular and TMJ injuries are difficult to access and stabilize using direct fixation techniques, thus indirect fixation is commonly employed. The immediate goals of fixation include stabilization for return to normal occlusion and function with the long-term objective of bony union. Indirect fixation techniques commonly used for stabilization of caudal mandibular and temporomandibular joint fracture/luxation include maxillomandibular fixation (MMF) with acrylic composite, interarcade wiring, tape muzzles, and the bignathic encircling and retaining device (BEARD) technique. This article introduces a modification of the previously described "labial reverse suture through buttons" technique used by Koestlin et al and the "labial locking with buttons" technique by Rocha et al. In cases with minimally displaced subcondylar and pericondylar fractures without joint involvement, the labial button technique can provide sufficient stabilization for healing. Advantages of the modified labial button technique include ease of application, noninvasive nature, and use of readily available materials. The construct can remain in place for a variable of amount of time, depending on its intended purpose. It serves as an alternative to the tape muzzle, which is rarely tolerated by cats. This technique can be easily used in conjunction with other maxillomandibular repairs, such as cerclage wire fixation of mandibular symphyseal separation. The purpose of this article is to demonstrate a modified labial button technique for maintaining occlusion of feline caudal mandibular fractures/TMJ luxations in a step-by-step fashion.
Direct and indirect light emissions from layered ReS2-x Se x (0 ≤ x ≤ 2)
NASA Astrophysics Data System (ADS)
Ho, Ching-Hwa; Liu, Zhan-Zhi; Lin, Min-Han
2017-06-01
ReS2 and ReSe2 have recently been enthusiastically studied owing to the specific in-plane electrical, optical and structural anisotropy caused by their distorted one-layer trigonal (1 T) phase, whereas other traditional transition-metal dichalcogenides (TMDCs, e.g. MoS2 and WSe2) have a hexagonal structure. Because of this special property, more and versatile nano-electronics and nano-optoelectronics devices can be developed. In this work, 2D materials in the series ReS2-x Se x (0 ≤ x ≤ 2) have been successfully grown by the method of chemical vapor transport. The direct and indirect resonant emissions of the complete series of layers can be simultaneously detected by polarized micro-photoluminescence (μPL) spectroscopy when the thickness of the ReS2-x Se x is greater than ˜70 nm. When it is less than 70 nm, only three direct excitonic emissions—E 1 ex, E 2 ex and E S ex—are detected. For the thick (bulk) ReS2-x Se x , more stacking of the ReX2 monolayers even flattens and shifts the valence-band maximum from Γ to the other K- or M-related points, thus leading to the coexistence of direct and indirect resonant light emissions from the c-plane ReX2. The transmittance absorption edge of each bulk ReX2 (a few microns thick) usually has a lower energy than those of the direct E 1 ex and E 2 ex excitonic emissions to form indirect absorption. The coexistence of direct and indirect emissions in ReX2 is a unique characteristic of a 2D layered semiconductor possessing triclinic low symmetry.
Liu, Rongchang; Chen, Cuiteng; Cheng, Longfei; Lu, Ronghui; Fu, Guanghua; Shi, Shaohua; Chen, Hongmei; Wan, Chunhe; Lin, Jiansheng; Fu, Qiuling; Huang, Yu
2017-07-28
Pasteurella multocida is an important pathogen of numerous domestic poultry and wild animals and is associated with a variety of diseases including fowl cholera. The aim of this study was to develop an indirect enzyme-linked immunosorbent assay (ELISA) based on recombinant outer-membrane protein H (rOmpH) for detection of anti-P. multocida antibodies in serum to determine their prevalence in Chinese ducks. The P. multocida ompH gene was cloned into pET32a, and rOmpH was expressed in Escherichia coli BL21 (DE3). Western blotting revealed that purified rOmpH was recognized by duck antisera against P. multocida, and an indirect ELISA was established. During analysis of serum samples (n=115) from ducks, the rOmpH ELISA showed 95.0% specificity, 100% sensitivity and a 92.0% κ coefficient (95% confidence interval 0.844-0.997) as compared with a microtiter agglutination test. Among 165 randomly selected serum samples, which were collected in 2015 and originated from six duck farms across Fujian Province, China, anti-P. multocida antibodies were detected in 22.42% of apparently healthy ducks, including 25 of 90 sheldrakes (27.8%), eight of 50 Peking ducks (16.0%) and four of 25 Muscovy ducks (16%). Overall, the data suggest that rOmpH is a suitable candidate antigen for the development of an indirect ELISA for detection of P. multocida in ducks; moreover, our results showed that ducks could serve as a potential reservoir for P. multocida infection.
Autologous Blood Transfusion in Sports: Emerging Biomarkers.
Salamin, Olivier; De Angelis, Sara; Tissot, Jean-Daniel; Saugy, Martial; Leuenberger, Nicolas
2016-07-01
Despite being prohibited by the World Anti-Doping Agency, blood doping through erythropoietin injection or blood transfusion is frequently used by athletes to increase oxygen delivery to muscles and enhance performance. In contrast with allogeneic blood transfusion and erythropoietic stimulants, there is presently no direct method of detection for autologous blood transfusion (ABT) doping. Blood reinfusion is currently monitored with individual follow-up of hematological variables via the athlete biological passport, which requires further improvement. Microdosage is undetectable, and suspicious profiles in athletes are often attributed to exposure to altitude, heat stress, or illness. Additional indirect biomarkers may increase the sensitivity and specificity of the longitudinal approach. The emergence of "-omics" strategies provides new opportunities to discover biomarkers for the indirect detection of ABT. With the development of direct quantitative methods, transcriptomics based on microRNA or messenger RNA expression is a promising approach. Because blood donation and blood reinfusion alter iron metabolism, quantification of proteins involved in metal metabolism, such as hepcidin, may be applied in an "ironomics" strategy to improve the detection of ABT. As red blood cell (RBC) storage triggers changes in membrane proteins, proteomic methods have the potential to identify the presence of stored RBCs in blood. Alternatively, urine matrix can be used for the quantification of the plasticizer di(2-ethyhexyl)phthalate and its metabolites that originate from blood storage bags, suggesting recent blood transfusion, and have an important degree of sensitivity and specificity. This review proposes that various indirect biomarkers should be applied in combination with mathematical approaches for longitudinal monitoring aimed at improving ABT detection. Copyright © 2016 Elsevier Inc. All rights reserved.
[Prenatal diagnosis. Review, personal and prospective studies].
Engel, E; Empson, J; DeLozier, D; McGee, B; da Costa Woodson, E; Engel-de Montmollin, M; Carter, T; Lorber, C; Cassidy, S B; Millis, J; Heller, R M; Boehm, F; Vanhooydonk, J
1979-07-07
1. In a review of methods developed for the identification of fetal malformations, the technique, risks and results of amniocentesis are presented. 2. Large series already published have demonstrated the relative simplicity and feasibility of the procedure as well as current indications for its utilization. These include the detection of chromosomal anomalies, the determination of sex (in certain sex-linked disorders), documentation of enzymatic and metabolic deficiencies, and the demonstration of open lesions of the neural tube by appropriate techniques. 3. Experience with over 500 cases personally tested by the authors entirely confirms the major indications for and benefits of this modern method for the detection and prevention of severe congenital anomalies during early pregnancy. 4. The identification of chromosomal alterations is currently the major objective of the method. Increased risks are associated with pregnancies involving a maternal age of 35 years or older (which account for 1-3% of aneuploidies), the birth of a previous infant with free trisomy 21 (1% recurrence risk) or secondary to a parental chromosome translocation (as much as 10% risk of aneuploidy). Fetal karyotyping for determination of sex, in cases where the mother is a carrier of an X-linked recessive gene (on average, 50% of male offspring will be affected), is an inadequate method of diagnosis to be utilized only until alternative techniques render possible specific diagnosis of the anomalies under consideration (hemophilias A and B, muscular dystrophy, etc). 5. Several of these techniques are now nearing development through the advent of fetoscopy and advanced ultrasound methodology, and have already been applied to the detection of certain sex-linked disorders and also for diagnosis of hemoglobinopathies (thalassemias, sickel cell anemia) and other conditions requiring the obtaining of fetal blood for diagnosis. Technology allowing direct examination of fetal parts by means of optical instruments is particularly useful in cases where a severe fetal morphologic malformation cannot currently be identified by indirect visualization (ultrasound) or by analysis of cytogenetic or molecular markers. 6. Pathological accumulations of alpha-fetoprotein which are associated with diverse feto-placental abnormalities (particularly open malformations of the neural tube) can be detected in the amniotic fluid and/or maternal blood. In extension of this approach, it is foreseeable that conditions existing prenatally will be diagnosed in a growing number of cases from the study of fetal cells and molecules which can be isolated from the venous blood of pregnant women. This will become feasible as a result of some well-developed techniques which allow separation of fetal from maternal cells and metabolites, and also to some extremely fine analytic techniques, notably examination of the DNA itself by means of restriction enzymes.
Evaluation of direct and indirect additive manufacture of maxillofacial prostheses.
Eggbeer, Dominic; Bibb, Richard; Evans, Peter; Ji, Lu
2012-09-01
The efficacy of computer-aided technologies in the design and manufacture of maxillofacial prostheses has not been fully proven. This paper presents research into the evaluation of direct and indirect additive manufacture of a maxillofacial prosthesis against conventional laboratory-based techniques. An implant/magnet-retained nasal prosthesis case from a UK maxillofacial unit was selected as a case study. A benchmark prosthesis was fabricated using conventional laboratory-based techniques for comparison against additive manufactured prostheses. For the computer-aided workflow, photogrammetry, computer-aided design and additive manufacture (AM) methods were evaluated in direct prosthesis body fabrication and indirect production using an additively manufactured mould. Qualitative analysis of position, shape, colour and edge quality was undertaken. Mechanical testing to ISO standards was also used to compare the silicone rubber used in the conventional prosthesis with the AM material. Critical evaluation has shown that utilising a computer-aided work-flow can produce a prosthesis body that is comparable to that produced using existing best practice. Technical limitations currently prevent the direct fabrication method demonstrated in this paper from being clinically viable. This research helps prosthesis providers understand the application of a computer-aided approach and guides technology developers and researchers to address the limitations identified.
Soluble Antigen Fluorescent-Antibody Technique
Toussaint, Andre J.; Anderson, Robert I.
1965-01-01
An indirect fluorescent-antibody (FA) procedure employing soluble antigen fixed onto an artificial matrix was developed, and a mechanical means for reading of test results was devised. The method employs two small cellulose acetate paper discs for each test. One disc contains soluble antigen diluted in 1% bovine serum albumin (BSA); the other contains only 1% BSA and serves as a control. After testing by the indirect FA procedure, the results of the tests are read on a fluorometer fitted with a paper chromatogram door. The instrument is set at zero with the control disc as a blank, and the specific fluorescence of the antigen disc is determined. Findings obtained with homologous and heterologous antisera indicated that the method yields excellent results. The soluble antigen fluorescent-antibody technique has definite advantages over the conventional indirect FA procedures. (i) The investigator may objectively select the antigen to be employed. (ii) It is possible to obtain objective mechanical reading of test results rather than the highly subjective readings required by conventional methods. (iii) The system compensates for any nonspecific fluorescence contributed either by the serum (e.g., drugs) or by free fluorescein in the conjugated antiserum. Images Fig. 1 PMID:14339261
NASA Astrophysics Data System (ADS)
Ghahremani, Mohammadreza; Aslani, Amir; Hosseinnia, Marjan; Bennett, Lawrence H.; Della Torre, Edward
2018-05-01
A systematic study of the magnetocaloric effect of a Ni51Mn33.4In15.6 Heusler alloy converted to nanoparticles via high energy ball-milling technique in the temperature range of 270 to 310 K has been performed. The properties of the particles were characterized by x-ray diffraction, electron microscopy, and magnetometer techniques. Isothermal magnetic field variation of magnetization exhibits field hysteresis in bulk Ni51Mn33.4In15.6 alloy across the martensitic transition which significantly lessened in the nanoparticles. The magnetocaloric effects of the bulk and nanoparticle samples were measured both with direct method, through our state of the art direct test bed apparatus with controllability over the applied fields and temperatures, as well as an indirect method through Maxwell and thermodynamic equations. In direct measurements, nanoparticle sample's critical temperature decreased by 6 K, but its magnetocaloric effect enhanced by 17% over the bulk counterpart. Additionally, when comparing the direct and indirect magnetocaloric curves, the direct method showed 14% less adiabatic temperature change in the bulk and 5% less adiabatic temperature change in the nanostructured sample.
1997-08-01
anti-neu antibody response of DNA vaccine immunized mice again by indirectly flowcytometry assay, we confirm our previous finding. We also examine the... flowcytometry assay, I have confirmed my previous finding from Elisa assay. 5 I also examined the cellular immunity response of DNA immunized mice by CTL...immunized mice by indirectly flowcytometry assay. I also find mice immunized with neu DNA vaccine did not develop detectable cytotoxic T lymphocyte
Kerkar, N; Ma, Y; Hussain, M; Muratori, L; Targett, C; Williams, R; Bianchi, F B; Mieli-Vergani, G; Vergani, D
1999-03-04
Liver Kidney Microsomal type 1 (LKM1) antibody, the diagnostic marker of autoimmune hepatitis type 2, is also found in a proportion of patients with hepatitis C virus infection (HCV). It is detected conventionally by the subjective immunofluorescence technique. Our aim was to establish a simple and objective enzyme-linked immunosorbent assay (ELISA) that measures antibodies to cytochrome P4502D6 (CYP2D6), the target of LKM1. An indirect ELISA using eukaryotically expressed CYP2D6 was designed. Absorbance values obtained against a reference microsomal preparation were subtracted from those obtained against a microsomal preparation over-expressing CYP2D6, thus removing the non-CYP2D6-specific reaction. Sera from 51 LKM1 positive patients (21 autoimmune hepatitis and 30 with HCV infection), 111 LKM1 negative patients with chronic liver disease (including 20 with HCV infection) and 43 healthy controls were tested. Of 51 patients positive by immunofluorescence, 48 were also positive by ELISA while all the 154 LKM1 negative subjects were also negative by ELISA. There was a high degree of association between IFL and ELISA as demonstrated by a kappa reliability value of 0.96. The absorbance values by ELISA correlated with immunofluorescence LKM1 titres both in autoimmune hepatitis (r = 0.74, p < 0.001) and HCV infection (r = 0.67, p < 0.001). The simple, objective ELISA described has the potential to replace the standard immunofluorescence technique.
Hamadto, H A; Rashid, S M; el-Fakahany, A F; Lashin, A H
1997-04-01
Toxoplasma antibodies were detected in sera of 700 cases; 500 were collected randomly from individuals attending the outpatient clinics of Benha University Hospitals of different ages and sexes and 200 from suspected inpatients from Obstetric, Opthalmology, Internal Medicine and Surgery Departments. The indirect fluorescent antibody technique was performed. The results were correlated with the clinical picture, age, sex and residence. The general positivity rate was 14.57%; in the random group, 11.2% and in suspected group, 23% (P < 0.001). Toxoplasma antibodies were more in females than in males in random group especially above 40 years old but with no obvious difference in rural and urban areas. In the suspected group, Toxoplasma positivity were 24% in Obstetric cases; 15% in hepatosplenomegalic cases, 17.5% in prolonged fever cases, 28.57% in ophthalmic cases and 40% in localised lymphadenopathy cases.
Estimating Driving Performance Based on EEG Spectrum Analysis
NASA Astrophysics Data System (ADS)
Lin, Chin-Teng; Wu, Ruei-Cheng; Jung, Tzyy-Ping; Liang, Sheng-Fu; Huang, Teng-Yi
2005-12-01
The growing number of traffic accidents in recent years has become a serious concern to society. Accidents caused by driver's drowsiness behind the steering wheel have a high fatality rate because of the marked decline in the driver's abilities of perception, recognition, and vehicle control abilities while sleepy. Preventing such accidents caused by drowsiness is highly desirable but requires techniques for continuously detecting, estimating, and predicting the level of alertness of drivers and delivering effective feedbacks to maintain their maximum performance. This paper proposes an EEG-based drowsiness estimation system that combines electroencephalogram (EEG) log subband power spectrum, correlation analysis, principal component analysis, and linear regression models to indirectly estimate driver's drowsiness level in a virtual-reality-based driving simulator. Our results demonstrated that it is feasible to accurately estimate quantitatively driving performance, expressed as deviation between the center of the vehicle and the center of the cruising lane, in a realistic driving simulator.
Stocker, Abigail; Abell, Thomas L.; Rashed, Hani; Kedar, Archana; Boatright, Ben; Chen, Jiande
2016-01-01
Background Disorders of nausea, vomiting, abdominal pain, and related problems often are manifestations of gastrointestinal, neuromuscular, and/or autonomic dysfunction. Many of these patients respond to neurostimulation, either gastric electrical stimulation or electroacupuncture. Both of these therapeutic techniques appear to influence the autonomic nervous system which can be evaluated directly by traditional testing and indirectly by heart rate variability. Methods We studied patients undergoing gastric neuromodulation by both systemic autonomic testing (39 patients, six males and 33 females, mean age 38 years) and systemic autonomic testing and heart rate variability (35 patients, seven males and 28 females, mean age 37 years) testing before and after gastric neuromodulation. We also performed a pilot study using both systemic autonomic testing and heart rate variability in a small number of patients (five patients, all females, mean age 48.6 years) with diabetic gastroparesis at baseline to compare the two techniques at baseline. Systemic autonomic testing and heart rate variability were performed with standardized techniques and gastric electrical stimulation was performed as previously described with electrodes implanted serosally in the myenteric plexus. Results Both systemic autonomic testing and heart rate variability measures were often abnormal at baseline and showed changes after gastric neuromodulation therapy in two groups of symptomatic patients. Pilot data on a small group of similar patients with systemic automatic nervous measures and heart rate variability showed good concordance between the two techniques. Conclusions Both traditional direct autonomic measures and indirect measures such as heart rate variability were evaluated, including a pilot study of both methods in the same patient group. Both appear to be useful in evaluation of patients at baseline and after stimulation therapies; however, a future full head-to-head comparison is warranted. PMID:27785318
The Use of Electromagnetic Induction Techniques for Soil Mapping
NASA Astrophysics Data System (ADS)
Brevik, Eric C.; Doolittle, Jim
2015-04-01
Soils have high natural spatial variability. This has been recognized for a long time, and many methods of mapping that spatial variability have been investigated. One technique that has received considerable attention over the last ~30 years is electromagnetic induction (EMI). Particularly when coupled with modern GPS and GIS systems, EMI techniques have allowed the rapid and relatively inexpensive collection of large spatially-related data sets that can be correlated to soil properties that either directly or indirectly influence electrical conductance in the soil. Soil electrical conductivity is directly controlled by soil water content, soluble salt content, clay content and mineralogy, and temperature. A wide range of indirect controls have been identified, such as soil organic matter content and bulk density; both influence water relationships in the soil. EMI techniques work best in areas where there are large changes in one soil property that influences soil electrical conductance, and don't work as well when soil properties that influence electrical conductance are largely homogenous. This presentation will present examples of situations where EMI techniques were successful as well as a couple of examples of situations where EMI was not so useful in mapping the spatial variability of soil properties. Reasons for both the successes and failures will be discussed.
[Comparison of several methods for detecting anti-erythrocyte alloantibodies].
Bencomo, A A
1990-08-01
The efficacy of different methods for anti-red cell antibodies detection was assessed, variations being found in accordance with the specificity of the alloantibodies. The usefulness of enzyme tests in anti-Rh antibody detection was demonstrated, as well as that of low ionic strength saline solutions in detecting anti-Kell, anti-Duffy and anti-Kidd antibodies. Serum precipitation with 15% polyethyleneglycol 8000 previously to indirect antiglobulin test was found the most sensitive method, providing the best results in all the antibodies studied.
NASA Astrophysics Data System (ADS)
Bukharin, M.; Khudakov, D.; Vartapetov, S.
The technique of writing depressed cladding waveguides into Nd:phosphate glass with relatively large mode field diameter in 2-line geometry was reported for the purposes of waveguiding structures formation. The easy to use and accurate technique of induced refractive index measurement was proposed, and it was shown the inefficiency of widespread indirect (numerical aperture) technique of refractive index measurement for such femtosecond written waveguides.
21 CFR 868.2377 - Apnea monitor.
Code of Federal Regulations, 2011 CFR
2011-04-01
... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...
21 CFR 868.2377 - Apnea monitor.
Code of Federal Regulations, 2014 CFR
2014-04-01
... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...
21 CFR 868.2377 - Apnea monitor.
Code of Federal Regulations, 2010 CFR
2010-04-01
... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...
21 CFR 868.2377 - Apnea monitor.
Code of Federal Regulations, 2013 CFR
2013-04-01
... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...
21 CFR 868.2377 - Apnea monitor.
Code of Federal Regulations, 2012 CFR
2012-04-01
... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...
NASA Astrophysics Data System (ADS)
Schlosser, D. M.; Hartmann, R.; Kalok, D.; Bechteler, A.; Abboud, A.; Shokr, M.; Çonka, T.; Pietsch, U.; Strüder, L.
2017-04-01
By combining a low noise fully depleted pnCCD detector with a columnar CsI(Tl) scintillator an energy dispersive spatial resolving detector can be realized with a high quantum efficiency in the range from below 0.5 keV to above 150 keV. The used scintillator system increases the pulse height of gamma-rays converted in the CsI(Tl), due to focusing properties of the columnar scintillator structure by reducing the event size in indirect detection mode (conversion in the scintillator). In case of direct detection (conversion in the silicon of the pnCCD) the relative energy resolution is 0.7% at 122 keV (FWHM = 850 eV) and the spatial resolution is less than 75 μm. In case of indirect detection the relative energy resolution, integrated over all event sizes is about 9% at 122 keV with an expected spatial precision of below 75 μm.
Indirect signals from solar dark matter annihilation to long-lived right-handed neutrinos
Allahverdi, Rouzbeh; Gao, Yu; Knockel, Bradley; ...
2017-04-04
In this paper, we study indirect detection signals from solar annihilation of dark matter (DM) particles into light right-handed (RH) neutrinos with a mass in a 1–5 GeV range. These RH neutrinos can have a sufficiently long lifetime to allow them to decay outside the Sun, and their delayed decays can result in a signal in gamma rays from the otherwise “dark” solar direction, and also a neutrino signal that is not suppressed by the interactions with solar medium. We find that the latest Fermi-LAT and IceCube results place limits on the gamma ray and neutrino signals, respectively. Combined photonmore » and neutrino bounds can constrain the spin-independent DM-nucleon elastic scattering cross section better than direct detection experiments for DM masses from 200 GeV up to several TeV. Finally, the bounds on spin-dependent scattering are also much tighter than the strongest limits from direct detection experiments.« less
Myint, K S; Linthicum, K J; Tanskul, P; Lerdthusnee, K; Vaughn, D W; Manomuth, C; Mongkolsirichaikul, D; Hansukjariya, P; Hastriter, M W
1998-07-01
Immunocytochemical methods were developed and tested for their ability to detect the distribution of Orientia tsutsugamushi in paraffin sections of adult chiggers (Leptotrombidium imphalum Vercammen-Grandjean & Langston). Rickettsial antigen was detected by application of a simple direct or amplified immunocytochemistry procedure and an indirect immunofluorescent procedure. In the direct procedure alkaline phosphatase conjugation to the mouse polyclonal antibody to the Karp strain was followed by the HistoMark Red test system to detect rickettsial antigen. The amplification procedure used a similar method but used an unlabeled primary antibody followed by secondary biotinylated antimouse IgG, streptavidin-alkaline phosphatase, and the HistoMark Red test system. The immunofluorescent procedure included a biotinylated secondary antibody followed by addition of a streptavidin-FITC conjugate. Specific tissue tropisms in infected chiggers were observed in the salivary glands, nervous tissue, and ovaries of adult female mites in all procedures; however, nonspecific fluorescence of the chigger limited definitive identification of tissue tropisms with the indirect immunofluorescent procedure.
ESR Measurement Of Crystallinity In Semicrystalline Polymers
NASA Technical Reports Server (NTRS)
Kim, Soon Sam; Tsay, Fun-Dow
1989-01-01
Photogenerated free radicals decay at different rates in crystalline and amorphous phases. Degree of crystallinity in polymer having both crystalline and amorphous phases measured indirectly by technique based in part on electron-spin-resonance (ESR) spectroscopy. Accuracy of crystallinity determined by new technique equals or exceeds similar determinations by differential scanning calorimetry, wide-angle x-ray scattering, or measurement of density.
Interest and limitations of projective techniques in the assessment of personality disorders.
Petot, J M
2000-06-01
Assessing personality disorders (PD) remains a difficult task because of persistent problems linked to concurrent validity of existing instruments, which are all structured interviews or self-report inventories. It has been advocated that indirect methods, projective techniques in particular, can strengthen PD assessment methods. The thematic apperception test (TAT) may be a significant adjuvant method of PD assessment.
Shuker, Sabri T
2013-07-01
Interrami intraoral Kirschner wire fixation technique is presented for the reduction, stabilization, and immobilization of a pulverized and avulsed lower jaw caused by rifle fragmented bullet injuries. This indirect mandibular war injury fixation technique was tolerated by the patients and tissue more than any indirect external fixation. In addition, it is easier than open reduction using large bone plates for disrupted ballistics mandibular injury defects. An interrami intraoral fixation is appropriate for severely disrupted mandibular hard and soft tissues, and has been adapted in cases of mass casualties and limited resources. Benefits of use include limited hospital beds and fewer follow-up visits. Rifle fragmented bullet injuries need more attention for several reasons: not only because of the higher mortality and devastating nature of the injuries, but also because these injuries are responsible for an unreported type of bullet biomechanism wounding in the craniofacial region. In turn, this necessitates specialized victim management. The survival rates depend on immediate proper execution of airway, breathing, and circulation, which become more complicated as it relates to airway compromise and oropharyngeal hemorrhage resuscitation. Survival is predicated on the implementation of feasible, sensible, life-saving techniques that are applied at the appropriate time.
Luong, Susan; Fu, Shanlin
2014-03-01
In vitro urine adulteration is a well-documented practice adopted by individuals aiming to evade detection of drug use, when required to undergo mandatory sports and workplace drug testing. Potassium nitrite is an effective urine adulterant due to its oxidizing potential, and has been shown to mask the presence of many drugs of abuse. However, limited research has been conducted to understand its mechanism of action, and to explore the possibility of the drugs undergoing direct oxidation to form stable reaction products. In this study, opiates including morphine, codeine, morphine-3-glucuronide and morphine-6-glucuronide were exposed to potassium nitrite in water and urine to mimic the process of nitrite adulteration. It was found that two stable reaction products were detected by liquid chromatography-mass spectrometry (LC-MS) when morphine and morphine-6-glucuronide were exposed to nitrite. Isolation and elucidation using spectrometric and spectroscopic techniques revealed that they were 2-nitro-morphine and 2-nitro-morphine-6-glucuronide, respectively. These reaction products were also formed when an authentic morphine-positive urine specimen was fortified with nitrite. 2-Nitro-morphine was found to be stable enough to undergo the enzymatic hydrolysis procedure and also detectable by gas chromatography-mass spectrometry (GC-MS) after forming a trimethylsilyl derivative. On the contrary, morphine-3-glucuronide did not appear to be chemically manipulated when exposed to potassium nitrite in urine. These reaction products are not endogenously produced, are relatively stable and can be monitored with both LC-MS and GC-MS confirmatory techniques. As a result, these findings have revealed the possibility for the use of 2-nitro-morphine and 2-nitro-morphine-6-glucuronide as markers for the indirect monitoring of morphine and morphine-6-glucuronide in urine specimens adulterated with nitrite. Copyright © 2013 John Wiley & Sons, Ltd.
Gas Leak Detection by Dilution of Atmospheric Oxygen
Lambrecht, Armin; Maier, Eric; Strahl, Thomas; Herbst, Johannes
2017-01-01
Gas leak detection is an important issue in infrastructure monitoring and industrial production. In this context, infrared (IR) absorption spectroscopy is a major measurement method. It can be applied in an extractive or remote detection scheme. Tunable laser spectroscopy (TLS) instruments are able to detect CH4 leaks with column densities below 10 ppm·m from a distance of 30 m in less than a second. However, leak detection of non-IR absorbing gases such as N2 is not possible in this manner. Due to the fact that any leaking gas displaces or dilutes the surrounding background gas, an indirect detection is still possible. It is shown by sensitive TLS measurements of the ambient background concentration of O2 that N2 leaks can be localized with extractive and standoff methods for distances below 1 m. Minimum leak rates of 0.1 mbar·L/s were determined. Flow simulations confirm that the leakage gas typically effuses in a narrow jet. The sensitivity is mainly determined by ambient flow conditions. Compared to TLS detection of CH4 at 1651 nm, the indirect method using O2 at 761 nm is experimentally found to be less sensitive by a factor of 100. However, the well-established TLS of O2 may become a universal tool for rapid leakage screening of vessels that contain unknown or inexpensive gases, such as N2. PMID:29206133
Airborne laser systems for atmospheric sounding in the near infrared
NASA Astrophysics Data System (ADS)
Sabatini, Roberto; Richardson, Mark A.; Jia, Huamin; Zammit-Mangion, David
2012-06-01
This paper presents new techniques for atmospheric sounding using Near Infrared (NIR) laser sources, direct detection electro-optics and passive infrared imaging systems. These techniques allow a direct determination of atmospheric extinction and, through the adoption of suitable inversion algorithms, the indirect measurement of some important natural and man-made atmospheric constituents, including Carbon Dioxide (CO2). The proposed techniques are suitable for remote sensing missions performed by using aircraft, satellites, Unmanned Aerial Vehicles (UAV), parachute/gliding vehicles, Roving Surface Vehicles (RSV), or Permanent Surface Installations (PSI). The various techniques proposed offer relative advantages in different scenarios. All are based on measurements of the laser energy/power incident on target surfaces of known geometric and reflective characteristics, by means of infrared detectors and/or infrared cameras calibrated for radiance. Experimental results are presented relative to ground and flight trials performed with laser systems operating in the near infrared (NIR) at λ = 1064 nm and λ = 1550 nm. This includes ground tests performed with 10 Hz and 20 KHz PRF NIR laser systems in a variety of atmospheric conditions, and flight trials performed with a 10 Hz airborne NIR laser system installed on a TORNADO aircraft, flying up to altitudes of 22,000 ft above ground level. Future activities are planned to validate the atmospheric retrieval algorithms developed for CO2 column density measurements, with emphasis on aircraft related emissions at airports and other high air-traffic density environments.
NASA Technical Reports Server (NTRS)
Ling, A. C.; Macpherson, L. H.; Rey, M.
1981-01-01
The potential use of isotopically excited energy dispersive X-ray fluorescence (XRF) spectrometry for automated on line fast real time (5 to 15 minutes) simultaneous multicomponent (up to 20) trace (1 to 10 parts per billion) analysis of inorganic pollutants in reclaimed water was examined. Three anionic elements (chromium 6, arsenic and selenium) were studied. The inherent lack of sensitivity of XRF spectrometry for these elements mandates use of a preconcentration technique and various methods were examined, including: several direct and indirect evaporation methods; ion exchange membranes; selective and nonselective precipitation; and complexation processes. It is shown tha XRF spectrometry itself is well suited for automated on line quality assurance, and can provide a nondestructive (and thus sample storage and repeat analysis capabilities) and particularly convenient analytical method. Further, the use of an isotopically excited energy dispersive unit (50 mCi Cd-109 source) coupled with a suitable preconcentration process can provide sufficient sensitivity to achieve the current mandated minimum levels of detection without the need for high power X-ray generating tubes.
A ten-year follow-up of human leptospirosis in Uruguay: an unresolved health problem.
Schelotto, Felipe; Hernández, Elba; González, Sabina; Del Monte, Alicia; Ifran, Silvana; Flores, Karina; Pardo, Lorena; Parada, Daniel; Filippini, Mercedes; Balseiro, Victoria; Geymonat, Juan Pablo; Varela, Gustavo
2012-01-01
Leptospira spp. are delicate bacteria that cannot be studied by usual microbiological methods. They cause leptospirosis, a zoonotic disease transmitted to humans through infected urine of wild or domestic animals. We studied the incidence of this disease in the Uruguayan population, its epidemiologic and clinical features, and compared diagnostic techniques. After examining 6,778 suspect cases, we estimated that about 15 infections/100,000 inhabitants occurred yearly, affecting mainly young male rural workers. Awareness about leptospirosis has grown among health professionals, and its lethality has consequently decreased. Bovine infections were probably the principal source of human disease. Rainfall volumes and floods were major factors of varying incidence. Most patients had fever, asthenia, myalgias or cephalalgia, with at least one additional abnormal clinical feature. 30-40% of confirmed cases presented abdominal signs and symptoms, conjunctival suffusion and altered renal or urinary function. Jaundice was more frequent in patients aged > 40 years. Clinical infections followed an acute pattern and their usual outcome was complete recovery. Laboratory diagnosis was based on indirect micro-agglutination standard technique (MAT). Second serum samples were difficult to obtain, often impairing completion of diagnosis. Immunofluorescence was useful as a screening test and for early detection of probable infections.
The Atmospheric Monitoring Strategy for the Cherenkov Telescope Array
NASA Astrophysics Data System (ADS)
Daniel, M. K.; CTA Consortium
2015-04-01
The Imaging Atmospheric Cherenkov Technique (IACT) is unusual in astronomy as the atmosphere actually forms an intrinsic part of the detector system, with telescopes indirectly detecting very high energy particles by the generation and transport of Cherenkov photons deep within the atmosphere. This means that accurate measurement, characterisation and monitoring of the atmosphere is at the very heart of successfully operating an IACT system. The Cherenkov Telescope Array (CTA) will be the next generation IACT observatory with an ambitious aim to improve the sensitivity of an order of magnitude over current facilities, along with corresponding improvements in angular and energy resolution and extended energy coverage, through an array of Large (23 m), Medium (12 m) and Small (4 m) sized telescopes spread over an area of order ~km2. Whole sky coverage will be achieved by operating at two sites: one in the northern hemisphere and one in the southern hemisphere. This proceedings will cover the characterisation of the candidate sites and the atmospheric calibration strategy. CTA will utilise a suite of instrumentation and analysis techniques for atmospheric modelling and monitoring regarding pointing forecasts, intelligent pointing selection for the observatory operations and for offline data correction.
Diffusion MRI in early cancer therapeutic response assessment
Galbán, C. J.; Hoff, B. A.; Chenevert, T. L.; Ross, B. D.
2016-01-01
Imaging biomarkers for the predictive assessment of treatment response in patients with cancer earlier than standard tumor volumetric metrics would provide new opportunities to individualize therapy. Diffusion-weighted MRI (DW-MRI), highly sensitive to microenvironmental alterations at the cellular level, has been evaluated extensively as a technique for the generation of quantitative and early imaging biomarkers of therapeutic response and clinical outcome. First demonstrated in a rodent tumor model, subsequent studies have shown that DW-MRI can be applied to many different solid tumors for the detection of changes in cellularity as measured indirectly by an increase in the apparent diffusion coefficient (ADC) of water molecules within the lesion. The introduction of quantitative DW-MRI into the treatment management of patients with cancer may aid physicians to individualize therapy, thereby minimizing unnecessary systemic toxicity associated with ineffective therapies, saving valuable time, reducing patient care costs and ultimately improving clinical outcome. This review covers the theoretical basis behind the application of DW-MRI to monitor therapeutic response in cancer, the analytical techniques used and the results obtained from various clinical studies that have demonstrated the efficacy of DW-MRI for the prediction of cancer treatment response. PMID:26773848
Direct Measurement of Pyroelectric and Electrocaloric Effects in Thin Films
NASA Astrophysics Data System (ADS)
Pandya, Shishir; Wilbur, Joshua D.; Bhatia, Bikram; Damodaran, Anoop R.; Monachon, Christian; Dasgupta, Arvind; King, William P.; Dames, Chris; Martin, Lane W.
2017-03-01
An understanding of polarization-heat interactions in pyroelectric and electrocaloric thin-film materials requires that the electrothermal response is reliably characterized. While most work, particularly in electrocalorics, has relied on indirect measurement protocols, here we report a direct technique for measuring both pyroelectric and electrocaloric effects in epitaxial ferroelectric thin films. We demonstrate an electrothermal test platform where localized high-frequency (approximately 1 kHz) periodic heating and highly sensitive thin-film resistance thermometry allow the direct measurement of pyrocurrents (<10 pA ) and electrocaloric temperature changes (<2 mK ) using the "2-omega" and an adapted "3-omega" technique, respectively. Frequency-domain, phase-sensitive detection permits the extraction of the pyrocurrent from the total current, which is often convoluted by thermally-stimulated currents. The wide-frequency-range measurements employed in this study further show the effect of secondary contributions to pyroelectricity due to the mechanical constraints of the substrate. Similarly, measurement of the electrocaloric effect on the same device in the frequency domain (at approximately 100 kHz) allows for the decoupling of Joule heating from the electrocaloric effect. Using one-dimensional, analytical heat-transport models, the transient temperature profile of the heterostructure is characterized to extract pyroelectric and electrocaloric coefficients.
Direct detection of a break in the teraelectronvolt cosmic-ray spectrum of electrons and positrons
NASA Astrophysics Data System (ADS)
DAMPE Collaboration; Ambrosi, G.; An, Q.; Asfandiyarov, R.; Azzarello, P.; Bernardini, P.; Bertucci, B.; Cai, M. S.; Chang, J.; Chen, D. Y.; Chen, H. F.; Chen, J. L.; Chen, W.; Cui, M. Y.; Cui, T. S.; D'Amone, A.; de Benedittis, A.; De Mitri, I.; di Santo, M.; Dong, J. N.; Dong, T. K.; Dong, Y. F.; Dong, Z. X.; Donvito, G.; Droz, D.; Duan, K. K.; Duan, J. L.; Duranti, M.; D'Urso, D.; Fan, R. R.; Fan, Y. Z.; Fang, F.; Feng, C. Q.; Feng, L.; Fusco, P.; Gallo, V.; Gan, F. J.; Gao, M.; Gao, S. S.; Gargano, F.; Garrappa, S.; Gong, K.; Gong, Y. Z.; Guo, D. Y.; Guo, J. H.; Hu, Y. M.; Huang, G. S.; Huang, Y. Y.; Ionica, M.; Jiang, D.; Jiang, W.; Jin, X.; Kong, J.; Lei, S. J.; Li, S.; Li, X.; Li, W. L.; Li, Y.; Liang, Y. F.; Liang, Y. M.; Liao, N. H.; Liu, H.; Liu, J.; Liu, S. B.; Liu, W. Q.; Liu, Y.; Loparco, F.; Ma, M.; Ma, P. X.; Ma, S. Y.; Ma, T.; Ma, X. Q.; Ma, X. Y.; Marsella, G.; Mazziotta, M. N.; Mo, D.; Niu, X. Y.; Peng, X. Y.; Peng, W. X.; Qiao, R.; Rao, J. N.; Salinas, M. M.; Shang, G. Z.; H. Shen, W.; Shen, Z. Q.; Shen, Z. T.; Song, J. X.; Su, H.; Su, M.; Sun, Z. Y.; Surdo, A.; Teng, X. J.; Tian, X. B.; Tykhonov, A.; Vagelli, V.; Vitillo, S.; Wang, C.; Wang, H.; Wang, H. Y.; Wang, J. Z.; Wang, L. G.; Wang, Q.; Wang, S.; Wang, X. H.; Wang, X. L.; Wang, Y. F.; Wang, Y. P.; Wang, Y. Z.; Wen, S. C.; Wang, Z. M.; Wei, D. M.; Wei, J. J.; Wei, Y. F.; Wu, D.; Wu, J.; Wu, L. B.; Wu, S. S.; Wu, X.; Xi, K.; Xia, Z. Q.; Xin, Y. L.; Xu, H. T.; Xu, Z. L.; Xu, Z. Z.; Xue, G. F.; Yang, H. B.; Yang, P.; Yang, Y. Q.; Yang, Z. L.; Yao, H. J.; Yu, Y. H.; Yuan, Q.; Yue, C.; Zang, J. J.; Zhang, C.; Zhang, D. L.; Zhang, F.; Zhang, J. B.; Zhang, J. Y.; Zhang, J. Z.; Zhang, L.; Zhang, P. F.; Zhang, S. X.; Zhang, W. Z.; Zhang, Y.; Zhang, Y. J.; Zhang, Y. Q.; Zhang, Y. L.; Zhang, Y. P.; Zhang, Z.; Zhang, Z. Y.; Zhao, H.; Zhao, H. Y.; Zhao, X. F.; Zhou, C. Y.; Zhou, Y.; Zhu, X.; Zhu, Y.; Zimmer, S.
2017-12-01
High-energy cosmic-ray electrons and positrons (CREs), which lose energy quickly during their propagation, provide a probe of Galactic high-energy processes and may enable the observation of phenomena such as dark-matter particle annihilation or decay. The CRE spectrum has been measured directly up to approximately 2 teraelectronvolts in previous balloon- or space-borne experiments, and indirectly up to approximately 5 teraelectronvolts using ground-based Cherenkov γ-ray telescope arrays. Evidence for a spectral break in the teraelectronvolt energy range has been provided by indirect measurements, although the results were qualified by sizeable systematic uncertainties. Here we report a direct measurement of CREs in the energy range 25 gigaelectronvolts to 4.6 teraelectronvolts by the Dark Matter Particle Explorer (DAMPE) with unprecedentedly high energy resolution and low background. The largest part of the spectrum can be well fitted by a ‘smoothly broken power-law’ model rather than a single power-law model. The direct detection of a spectral break at about 0.9 teraelectronvolts confirms the evidence found by previous indirect measurements, clarifies the behaviour of the CRE spectrum at energies above 1 teraelectronvolt and sheds light on the physical origin of the sub-teraelectronvolt CREs.
Dark forces in the sky: signals from Z{sup ′} and the dark Higgs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bell, Nicole F.; Cai, Yi; Leane, Rebecca K.
2016-08-01
We consider the indirect detection signals for a self-consistent hidden U(1) model containing a Majorana dark matter candidate, χ, a dark gauge boson, Z{sup ′}, and a dark Higgs, s. Compared with a model containing only a dark matter candidate and Z{sup ′} mediator, the addition of the scalar provides a mass generation mechanism for the dark sector particles and is required in order to avoid unitarity violation at high energies. We find that the inclusion of the two mediators opens up a new two-body s-wave annihilation channel, χχ→sZ{sup ′}. This new process, which is missed in the usual single-mediatormore » simplified model approach, can be the dominant annihilation channel. This provides rich phenomenology for indirect detection searches, allows indirect searches to explore regions of parameter space not accessible with other commonly considered s-wave annihilation processes, and enables both the Z{sup ′} and scalar couplings to be probed. We examine the phenomenology of the sector with a focus on this new process, and determine the limits on the model parameter space from Fermi data on dwarf spheriodal galaxies and other relevant experiments.« less
Derelioglu, Sera
2016-01-01
Objective. The aim of this study was to compare to fracture resistance test of inlay restorations prepared using direct inlay technique (Gradia® Direct Composite) and Indirect Restoration System® (Gradia Indirect Composite) and CAD/CAD system (Vita Enamic® Block). Study Design. 48 noncarious extracted maxillary second primary molars were randomly divided into 4 groups with 12 in each group. All the teeth were prepared based on inlay class II preparations except for the control group. Other groups were restored with Gradia Direct Composite, Gradia Indirect Composite, and Vita Enamic Block, respectively. All restorations were cemented self-adhesive dual cure resin (3M Espe, RelyX™ Unicem Aplicap). A fracture test was performed using a compressive load. Results were analyzed using one-way analysis of variance and Duncan's post hoc multiple comparison tests (α = 0.05). Results. Vita Enamic Block and Gradia Indirect Composite showed significantly higher fracture resistance than Gradia Direct Composite (p < 0.05). There was no significant difference fracture resistance between Vita Enamic Block and Gradia Indirect Composite (p > 0.05). All restorations tested led to a significant reduction in fracture resistance (p < 0.05). Conclusion. In inlay restorations, Indirect Restoration Systems and CAD/CAM systems were applied successfully together with the self-adhesive dual cure resin cements in primary molars. PMID:27830145
NASA Astrophysics Data System (ADS)
Shen, Ming; Trébosc, Julien; O'Dell, Luke A.; Lafon, Olivier; Pourpoint, Frédérique; Hu, Bingwen; Chen, Qun; Amoureux, Jean-Paul
2015-09-01
We present an experimental comparison of several through-space Hetero-nuclear Multiple-Quantum Correlation experiments, which allow the indirect observation of homo-nuclear single- (SQ) or double-quantum (DQ) 14N coherences via spy 1H nuclei. These 1H-{14N} D-HMQC sequences differ not only by the order of 14N coherences evolving during the indirect evolution, t1, but also by the radio-frequency (rf) scheme used to excite and reconvert these coherences under Magic-Angle Spinning (MAS). Here, the SQ coherences are created by the application of center-band frequency-selective pulses, i.e. long and low-power rectangular pulses at the 14N Larmor frequency, ν0(14N), whereas the DQ coherences are excited and reconverted using rf irradiation either at ν0(14N) or at the 14N overtone frequency, 2ν0(14N). The overtone excitation is achieved either by constant frequency rectangular pulses or by frequency-swept pulses, specifically Wide-band, Uniform-Rate, and Smooth-Truncation (WURST) pulse shapes. The present article compares the performances of four different 1H-{14N} D-HMQC sequences, including those with 14N rectangular pulses at ν0(14N) for the indirect detection of homo-nuclear (i) 14N SQ or (ii) DQ coherences, as well as their overtone variants using (iii) rectangular or (iv) WURST pulses. The compared properties include: (i) the sensitivity, (ii) the spectral resolution in the 14N dimension, (iii) the rf requirements (power and pulse length), as well as the robustness to (iv) rf offset and (v) MAS frequency instabilities. Such experimental comparisons are carried out for γ-glycine and L-histidine.HCl monohydrate, which contain 14N sites subject to moderate quadrupole interactions. We demonstrate that the optimum choice of the 1H-{14N} D-HMQC method depends on the experimental goal. When the sensitivity and/or the robustness to offset are the major concerns, the D-HMQC sequence allowing the indirect detection of 14N SQ coherences should be employed. Conversely, when the highest resolution and/or adjusted indirect spectral width are needed, overtone experiments are the method of choice. The overtone scheme using WURST pulses results in broader excitation bandwidths than that using rectangular pulses, at the expense of reduced sensitivity. Numerically exact simulations also show that the sensitivity of the overtone 1H-{14N} D-HMQC experiment increases for larger quadrupole interactions.
France, Logan K; Vermillion, Meghan S; Garrett, Caroline M
2018-01-01
Blood pressure is a critical parameter for evaluating cardiovascular health, assessing effects of drugs and procedures, monitoring physiologic status during anesthesia, and making clinical decisions. The placement of an arterial catheter is the most direct and accurate method for measuring blood pressure; however, this approach is invasive and of limited use during brief sedated examinations. The objective of this study was to determine which method of indirect blood pressure monitoring was most accurate compared with measurement by direct arterial catheterization. In addition, we sought to determine the relative accuracy of each indirect method (compared with direct arterial measurement) at a given body location and to assess whether the accuracy of each indirect method was dependent on body location. We compared direct blood pressure measurements by means of catheterization of the saphenous artery with oscillometric and ultrasonic Doppler flow detection measurements at 3 body locations (forearm, distal leg, and tail base) in 16 anesthetized, male rhesus macaques. The results indicate that oscillometry at the forearm is the best indirect method and location for accurately and consistently measuring blood pressure in healthy male rhesus macaques.
Bai, Yubin; Hill, P. Aru; Dmochowski, Ivan J.
2012-01-01
Hyperpolarized 129Xe chemical exchange saturation transfer (129Xe Hyper-CEST) NMR is a powerful technique for the ultrasensitive, indirect detection of Xe host molecules (e.g., cryptophane-A). Irradiation at the appropriate Xe-cryptophane resonant radio frequency results in relaxation of the bound hyperpolarized 129Xe and rapid accumulation of depolarized 129Xe in bulk solution. The cryptophane effectively ‘catalyzes’ this process by providing a unique molecular environment for spin depolarization to occur, while allowing xenon exchange with the bulk solution during the hyperpolarized lifetime (T1 ≈ 1 min). Following this scheme, a triacetic acid cryptophane-A derivative (TAAC) was indirectly detected at 1.4 picomolar concentration at 320 K in aqueous solution, which is the record for a single-unit xenon host. To investigate this sensitivity enhancement, the xenon binding kinetics of TAAC in water was studied by NMR exchange lifetime measurement. At 297 K, kon ≈ 1.5 × 106 M−1s−1 and koff = 45 s−1, which represent the fastest Xe association and dissociation rates measured for a high-affinity, water-soluble xenon host molecule near rt. NMR linewidth measurements provided similar exchange rates at rt, which we assign to solvent-Xe exchange in TAAC. At 320 K, koff was estimated to be 1.1 × 103 s−1. In Hyper-CEST NMR experiments, the rate of 129Xe depolarization achieved by 14 pM TAAC in the presence of RF pulses was calculated to be 0.17 µM·s−1. On a per cryptophane basis, this equates to 1.2 × 104 129Xe atoms s−1 (or 4.6 × 104 Xe atoms s−1, all Xe isotopes), which is more than an order of magnitude faster than koff, the directly measurable Xe-TAAC exchange rate. This compels us to consider multiple Xe exchange processes for cryptophane-mediated bulk 129Xe depolarization, which provide at least 107-fold sensitivity enhancements over directly detected hyperpolarized 129Xe NMR signals. PMID:23106513
Li, Xiaoli; Liu, Xiaomin
2014-01-01
In the last two decades, functional near-infrared spectroscopy (fNIRS) is getting more and more popular as a neuroimaging technique. The fNIRS instrument can be used to measure local hemodynamic response, which indirectly reflects the functional neural activities in human brain. In this study, an easily implemented way to establish DAQ-device-based fNIRS system was proposed. Basic instrumentation components (light sources driving, signal conditioning, sensors, and optical fiber) of the fNIRS system were described. The digital in-phase and quadrature demodulation method was applied in LabVIEW software to distinguish light sources from different emitters. The effectiveness of the custom-made system was verified by simultaneous measurement with a commercial instrument ETG-4000 during Valsalva maneuver experiment. The light intensity data acquired from two systems were highly correlated for lower wavelength (Pearson's correlation coefficient r = 0.92, P < 0.01) and higher wavelength (r = 0.84, P < 0.01). Further, another mental arithmetic experiment was implemented to detect neural activation in the prefrontal cortex. For 9 participants, significant cerebral activation was detected in 6 subjects (P < 0.05) for oxyhemoglobin and in 8 subjects (P < 0.01) for deoxyhemoglobin. PMID:25180044
VizieR Online Data Catalog: Dark matter in dSph galaxies (Charbonnier+, 2011)
NASA Astrophysics Data System (ADS)
Charbonnier, A.; Combet, C.; Daniel, M.; Funk, S.; Hinton, J. A.; Maurin, D.; Power, C.; Read, J. I.; Sarkar, S.; Walker, M. G.; Wilkinson, M. I.
2012-07-01
Due to their large dynamical mass-to-light ratios, dwarf spheroidal galaxies (dSphs) are promising targets for the indirect detection of dark matter (DM) in γ-rays. We examine their detectability by present and future γ-ray observatories. The key innovative features of our analysis are as follows: (i) we take into account the angular size of the dSphs; while nearby objects have higher γ-ray flux, their larger angular extent can make them less attractive targets for background-dominated instruments; (ii) we derive DM profiles and the astrophysical J-factor (which parametrizes the expected γ-ray flux, independently of the choice of DM particle model) for the classical dSphs directly from photometric and kinematic data. We assume very little about the DM profile, modelling this as a smooth split-power-law distribution, with and without subclumps; (iii) we use a Markov chain Monte Carlo technique to marginalize over unknown parameters and determine the sensitivity of our derived J-factors to both model and measurement uncertainties; and (iv) we use simulated DM profiles to demonstrate that our J-factor determinations recover the correct solution within our quoted uncertainties. (6 data files).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bae, Kyu Jung; Baer, Howard; Serce, Hasan, E-mail: kyujungbae@ibs.re.kr, E-mail: baer@nhn.ou.edu, E-mail: serce@ou.edu
Under the expectation that nature is natural, we extend the Standard Model to include SUSY to stabilize the electroweak sector and PQ symmetry to stabilize the QCD sector. Then natural SUSY arises from a Kim-Nilles solution to the SUSY μ problem which allows for a little hierarchy where μ∼ f {sub a} {sup 2}/ M {sub P} {sub ∼} 100−300 GeV while the SUSY particle mass scale m {sub SUSY}∼ 1−10 TeV >> μ. Dark matter then consists of two particles: a higgsino-like WIMP and a SUSY DFSZ axion. The range of allowed axion mass values m {sub a} dependsmore » on the mixed axion-higgsino relic density. The range of m {sub a} is actually restricted in this case by limits on WIMPs from direct and indirect detection experiments. We plot the expected axion detection rate at microwave cavity experiments. The axion-photon-photon coupling is severely diminished by charged higgsino contributions to the anomalous coupling. In this case, the axion may retreat, at least temporarily, back into the regime of near invisibility. From our results, we urge new ideas for techniques which probe both deeper and more broadly into axion coupling versus axion mass parameter space.« less
Heterogeneity of neutrophil antibodies in patients with primary Sjögren's syndrome.
Lamour, A; Le Corre, R; Pennec, Y L; Cartron, J; Youinou, P
1995-11-01
Our aims were to determine the prevalence of neutrophil antibodies in patients with primary Sjögren's syndrome (pSS), identify their target antigen(s), and evaluate their functional significance. Neutrophil antibodies were detected using an indirect immunofluorescence (IIIF) test and an enzyme-linked immunosorbent assay (ELISA), using recombinant human Fc-gamma receptor (Fc gamma RIIIb) as a capture agent. Luminol-dependent chemiluminescence was then measured by an established technique. Antibodies to neutrophils were detected in 30 of 66 patients (45%) and categorized on the basis of positivity for the two assays: IIF+/ELISA+ (group A: five patients), IIF+/ELISA- (group B: five patients), and IFF-/ELISA+ (group C: 20 patients). All positive sera contained antibodies directed to the neutrophil specific Fc gamma RIIIb, and none of them bound to NAnull neutrophils. The titer of neutrophil-reactive antibodies (groups A and B) showed no correlation with the neutrophil count, but these autoantibodies did reduce the cell ability to generate a respiratory burst. Thus, neutrophil antibodies are common in patients with pSS. Their main target appears to be Fc gamma RIII, and this may partly account for the dysfunction in Fc gamma R-mediated clearance by the reticuloendothelial system reported in these patients.
Anti-polymorphonuclear neutrophil antibodies in patients with leukopenia or neutropenia.
Riera, N E; Rosso Saltó, M; Galán, V; Canalejo, K; Khoury, M; Aixalá, M; Kantor, G L; Vermeulen, M; Bengió, R; De Bracco, M M E
2010-02-01
Immune humoral neutropenia (Np) could be the consequence of anti-polymorphonuclear neutrophil (PMN) antibodies, circulating immune complexes (CIC) and/or antibodies against myeloid precursors. Granulocyte immunofluorescence test (GIFT) and a leukoagglutination technique (LAGT) assays are recommended for its diagnosis. Fifty adult patients with secondary Np were screened for anti-PMN. GIFT by flow cytometry from viable PMN and LAGT were employed. In addition, CIC levels, low expression of CD16(b) (CD16 (b)(low)), PMN phenotype and sera tumor necrosis factor-alpha (TNF-alpha) were also evaluated. Direct IgG-PMN binding (dir-GIFT) was positive in 16% of the patients. Antibodies against autologous PMN were detected in 32% of the samples by indirect (ind)-GIFT and demonstrated in 70% of the sera by both ind-GIFT and/or LAGT. Predominance of human neutrophil alloantigen (HNA)-1b and HNA-2 expression was confirmed. CD16(b)(low) was detected in 16% of the patient's PMN and TNF-alpha in 68% of sera patients. Our results suggest that diagnosis of immune Np in the laboratory may be improved by focusing on patient's PMN together with the assessment of cellular markers.
Capillary Electrophoresis - Optical Detection Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sepaniak, M. J.
2001-08-06
Molecular recognition systems are developed via molecular modeling and synthesis to enhance separation performance in capillary electrophoresis and optical detection methods for capillary electrophoresis. The underpinning theme of our work is the rational design and development of molecular recognition systems in chemical separations and analysis. There have been, however, some subtle and exciting shifts in our research paradigm during this period. Specifically, we have moved from mostly separations research to a good balance between separations and spectroscopic detection for separations. This shift is based on our perception that the pressing research challenges and needs in capillary electrophoresis and electrokinetic chromatographymore » relate to the persistent detection and flow rate reproducibility limitations of these techniques (see page 1 of the accompanying Renewal Application for further discussion). In most of our work molecular recognition reagents are employed to provide selectivity and enhance performance. Also, an emerging trend is the use of these reagents with specially-prepared nano-scale materials. Although not part of our DOE BES-supported work, the modeling and synthesis of new receptors has indirectly supported the development of novel microcantilevers-based MEMS for the sensing of vapor and liquid phase analytes. This fortuitous overlap is briefly covered in this report. Several of the more significant publications that have resulted from our work are appended. To facilitate brevity we refer to these publications liberally in this progress report. Reference is also made to very recent work in the Background and Preliminary Studies Section of the Renewal Application.« less
Olaciregui, M; Luño, V; Martí, J I; Aramayona, J; Gil, L
2016-11-01
During the freeze-drying procedure, sperm DNA might become damaged by both freezing and drying stresses. Sperm DNA status can be detected using well-established assays; however, most techniques are expensive and involve elaborate protocols and equipment. Indirect assessments can provide alternative strategies. The objective of this study was to compare a simple test of DNA status using Diff-Quik (DQ) with two established procedures: acridine orange test (AOT) and sperm chromatin dispersion (SCD) on freeze-dried (FD) stallion spermatozoa. Ejaculated spermatozoa from three stallions were freeze-dried in basic medium supplemented with two different chelating agents: EGTA or EDTA. After rehydration, the spermatozoa were subjected to DNA damage detection using a SCDt, AOT and DQ stain simultaneously. The results showed that the DNA damage levels in the EGTA group were significantly lower than those in the EDTA group. AOT detected a significantly higher proportion of spermatozoa with fragmented DNA than DQ and SCD. The results of the SCD test and DQ stain exhibited a significant positive correlation for DNA fragmentation (r = 0.528), whereas a negative correlation was observed between SCD, DQ and AOT (r = -0.134 and r = -0.332 respectively). The present study shows that both the SCD test and DQ assay are effective methods for detecting FD stallion sperm DNA fragmentation, whereas using of AOT is questionable. © 2016 Blackwell Verlag GmbH.
Indirect measurements of hydrogen: The deficit method for a many-component system
NASA Astrophysics Data System (ADS)
Levine, Timothy E.; Yu, Ning; Kodali, Padma; Walter, Kevin C.; Nastasi, Michael; Tesmer, Joseph R.; Maggiore, Carl J.; Mayer, James W.
We have developed a simple technique for determining hydrogen atomic fraction from the ion backscattering spectrometry (IBS) signals of the remaining species. This technique uses the surface heights of various IBS signals in the form of a linear matrix equation. We apply this technique to in situ analysis of ion-beam-induced densification of sol-gel zirconia thin films, where hydrogen is the most volatile species during irradiation. Attendant errors are discussed with an emphasis on stopping powers and Bragg's rule.
Lu, Shi-Ying; Zhou, Yu; Li, Yan-Song; Lin, Chao; Meng, Xian-Mei; Yan, Dong-Ming; Li, Zhao-Hui; Yu, Shi-Yu; Liu, Zeng-Shan; Ren, Hong-Lin
2011-08-01
Okadaic acid (OA) and analogues of dinophysistoxin (DTX) are key diarrheic shellfish poisoning (DSP) toxins, which possibly arouse DSP symptoms by consuming the contaminated shellfish. Because of the stable toxicity in high temperature and the long-term carcinogenicity, the outbreaks of DSP related to consumption of bivalve mollusks contaminated by DSP toxins pose a hazard to public health. Therefore, it is worth developing a fast and reliable analytical method for the detection of OA and analogues in shellfish. In this paper, an indirect competitive enzyme-linked immunosorbent assay (ELISA) (icELISA) for detecting OA and DTX-1 in seafood was developed based on monoclonal antibody (McAb). The OA was conjugated to human immunoglobulin G (IgG) and bovine serum albumin (BSA) by the active ester method as the immune antigen and the detective antigen. The spleen cells from BALB/c mice immunized with OA-IgG were fused with SP2/0 myeloma cells. A hybridoma cell line, which secreted McAb against OA, was selected by "limiting dilution" cloning. An icELISA was developed based on immobilized conjugate (OA-BSA) competing the McAb with the free OA in seafood sample. A hybridoma cell line, which secreted IgG1 subclass monoclonal antibody (McAb) against OA, was selected. The IC(50) of the McAb for OA and dinophytoxin-1 (DTX-1) were 4.40 and 3.89 ng/mL, respectively. Based on the McAb, an indirect competitive ELISA for detection of OA and DTX-1 in seafood was developed. The regression equation was y = 54.713x - 25.879 with a coefficient correlation of R (2) = 0.9729. The linear range and the limit of detection were 0.4-12.5 and 0.45 ng/mL, respectively. The average recovery of OA and DTX-1 spiked shellfish was 82.29% with the coefficient of variation of 7.67%. The developed icELISA is a fast, sensitive, and convenient assay for detecting of total amount of OA and DTX-1 in seafood.
Huguet, S; Sghiri, R; Ballot, E; Johanet, C
2004-01-01
The Cyto-Dot 4 HM043 kit commercialised by BMD, has replaced the Cyto-Dot HM010 kit that allowed three auto-antibodies detection (anti-Jo-1, anti-M2 and anti-ribosomal protein). Detection of anti-LKM1 auto-antibody was added. These four auto-antibodies have in common only the intracytoplasmic localisation of their respective antigen. The aim of our study was to evaluate this new kit using 104 sera and to compare our results with reference techniques (indirect immunofluorescence IF for anti-M2, anti-ribosomal protein and anti-LKM1, double immunodiffusion ID for anti-Jo-1 and anti-LKM1, western blotting WB for anti-M2) and with Cyto-Dot HM010. The one hundred and four sera were divided into five groups: Group I (n = 12) with anti-Jo-1 detected by ID; Group II (n = 28) with 26 anti-M2 positive by IF and WB, 2 anti-M2 positive only by WB; Group III (n = 10) with anti-ribosomal protein detected by IF 5 of which precipitated by ID; Group IV (n = 32) with anti-LKM1 by IF and ID divided into 18 AIH2 and 14 HCV; Group V (n = 22) consisting of 14 healthy individuals and 8 patients with hypergammaglobulinemia. Results of this study are similar to those of Cyto-Dot HM010 for the three auto-antibodies already in use. Cyto-Dot 4 is a very good anti-LKM1 confirmation method as it is ID. Copyright John Libbey Eurotext 2003.
A novel method for sex determination by detecting the number of X chromosomes.
Nakanishi, Hiroaki; Shojo, Hideki; Ohmori, Takeshi; Hara, Masaaki; Takada, Aya; Adachi, Noboru; Saito, Kazuyuki
2015-01-01
A novel method for sex determination, based on the detection of the number of X chromosomes, was established. Current methods, based on the detection of the Y chromosome, can directly identify an unknown sample as male, but female gender is determined indirectly, by not detecting the Y chromosome. Thus, a direct determination of female gender is important because the quality (e.g., fragmentation and amelogenin-Y null allele) of the Y chromosome DNA may lead to a false result. Thus, we developed a novel sex determination method by analyzing the number of X chromosomes using a copy number variation (CNV) detection technique (the comparative Ct method). In this study, we designed a primer set using the amelogenin-X gene without the CNV region as the target to determine the X chromosome copy number, to exclude the influence of the CNV region from the comparative Ct value. The number of X chromosomes was determined statistically using the CopyCaller software with real-time PCR. All DNA samples from participants (20 males, 20 females) were evaluated correctly using this method with 1-ng template DNA. A minimum of 0.2-ng template DNA was found to be necessary for accurate sex determination with this method. When using ultraviolet-irradiated template DNA, as mock forensic samples, the sex of the samples could not be determined by short tandem repeat (STR) analysis but was correctly determined using our method. Thus, we successfully developed a method of sex determination based on the number of X chromosomes. Our novel method will be useful in forensic practice for sex determination.
Anesthetic technique for inferior alveolar nerve block: a new approach
PALTI, Dafna Geller; de ALMEIDA, Cristiane Machado; RODRIGUES, Antonio de Castro; ANDREO, Jesus Carlos; LIMA, José Eduardo Oliveira
2011-01-01
Background Effective pain control in Dentistry may be achieved by local anesthetic techniques. The success of the anesthetic technique in mandibular structures depends on the proximity of the needle tip to the mandibular foramen at the moment of anesthetic injection into the pterygomandibular region. Two techniques are available to reach the inferior alveolar nerve where it enters the mandibular canal, namely indirect and direct; these techniques differ in the number of movements required. Data demonstrate that the indirect technique is considered ineffective in 15% of cases and the direct technique in 1329% of cases. Objective Objective: The aim of this study was to describe an alternative technique for inferior alveolar nerve block using several anatomical points for reference, simplifying the procedure and enabling greater success and a more rapid learning curve. Materials and Methods A total of 193 mandibles (146 with permanent dentition and 47 with primary dentition) from dry skulls were used to establish a relationship between the teeth and the mandibular foramen. By using two wires, the first passing through the mesiobuccal groove and middle point of the mesial slope of the distolingual cusp of the primary second molar or permanent first molar (right side), and the second following the oclusal plane (left side), a line can be achieved whose projection coincides with the left mandibular foramen. Results The obtained data showed correlation in 82.88% of cases using the permanent first molar, and in 93.62% of cases using the primary second molar. Conclusion This method is potentially effective for inferior alveolar nerve block, especially in Pediatric Dentistry. PMID:21437463
Wang, G; Ding, J; Hu, S; Yang, X
2012-10-01
Fragment of 759 bp DNA spanning the Matrix 1 (M1) gene of Avian Influenza Virus (AIV) was inserted into an expression vector pET28c to construct a recombinant plasmid pET28c-M1. The pET28c-M1 plasmid was transformed into the Escherichia coli BL21 (DE3) competent cell to produce a recombinant strain E. coli 21 (DE3). After being induced by Isopropyl-b-D-galactopyranoside (IPTG), E. coli 21 (DE3) expressed a 28-kDa fusion protein at a high level. This protein can bind anti-AIV (H5N1) positive serum by Western-blot analysis. After being denatured, renatured, and purified by Ni(2+)-column, the fusion protein was used as an antigen to develop Matrix 1 Enzyme-Linked Immunosorbent Assay (M1-ELISA) for detecting antibodies against AIV from chicken serum. We found that this indirect M1-ELISA was sensitive for differentiating antisera against AIV and antisera against other six kinds of avian viruses apart from AIV and this method is more sensitive than Hemagglutination Inhibition (HI) test. When compared with HI test and ELISA (IDEXX) in evaluating 581 serum samples from field vaccinated chickens, this assay showed 93.3% agreement ratio with the HI test, as well as 96.0% agreement ratio with ELISA (IDEXX). In a preliminary application, the assay successfully detected 19 AIVs from 51 nonvaccinated chicken lungs. It concludes that an indirect ELISA was successfully developed for detecting AIV. The assay is specific and sensitive. The application will greatly contribute to the long-term prevention and control of avian influenza in China. Copyright © 2011 Elsevier Ltd. All rights reserved.
Ghasemi, Negin; Janani, Maryam; Razi, Tahmineh; Atharmoghaddam, Faezeh
2017-03-01
It is necessary apical plug material to exhibit proper adaptation with the root canal walls. Presence of voids at the interface between the root canal wall and this material result in micro leakage, which might have a relationship with post treatment disease. The aim of the present study was to evaluate the effect of different mixing (manual and ultrasonic) and placement (manual and manual in association with indirect ultrasonic) method of Mineral Trioxide Aggregate (MTA) on the void count and dimension in the apical plug in natural teeth with simulated open apices. Eighty human maxillary central incisors were selected. After simulation of the open apex model, the teeth were assigned to 4 groups based on the mixing and placement techniques of MTA: group 1, manual mixing and manual placement; group 2, manual mixing and manual placement in association with indirect ultrasonic; group 3, ultrasonic mixing and and manual placement; and group 4, ultrasonic mixing and manual placement in association with indirect ultrasonic. The prepared samples were placed within gypsum sockets in which the periodontal ligament was reconstructed with polyether impression material. In group 1, after mixing, the material was condensed with a hand plugger. In group 2, after mixing, the ultrasonic tip was contacted with the hand plugger for 2 seconds. In groups 3 and 4, mixing was carried out with the ultrasonic tip for 5 seconds and in groups 3 and 4, similar to groups 1 and 2, respectively, the materials were placed as apical plugs, measuring 3 mm in length. A wet cotton pellet was placed at canal orifices and dressed with Cavit. After one week, the cone beam computed tomography (CBCT) technique was used to count the number of voids between the material and root canal walls. The void dimensions were determined using the following scoring system: score 1, absence of voids; score 2, the void size less than half of the dimensions of the evaluated cross-section; score 3, the void size larger than half of the dimensions of the evaluated cross-section. Chi-squared and Fisher's exact tests were used for statistical analyses. Statistical significance was set at P <0.05. The maximum (13) and minimum (3) number of voids were detected in groups 2 and 3, respectively. There were no significant differences between groups 1 and 3 in the number of voids ( p >0.05). Evaluation of void dimensions showed no score 3 in any of the study groups and the dimensions of all the voids conformed to score 2. Under the limitations of the present study, use of ultrasonic mixing and manual placement techniques resulted in a decrease in the number of voids in the apical plug. Key words: Apical plug, MTA, ultrasonic, void.
ERIC Educational Resources Information Center
Eyengho, Toju; Fawole, Oyebisi
2013-01-01
The study assessed error-correction techniques used in correcting students' essays in English language and also determined the effects of these strategies and other related variables on students' performance in essay writing with a view to improving students' writing skill in English language in South Western Nigeria. A quasi-experimental design…
Determining soil volumetric moisture content using time domain reflectometry
DOT National Transportation Integrated Search
1998-02-01
Time domain reflectometry (TDR) is a technique used to measure indirectly the in situ volumetric moisture content of soil. Current research provides a variety of prediction equations that estimate the volumetric moisture content using the dielectric ...
NASA Technical Reports Server (NTRS)
Miles, Jeffrey Hilton
2011-01-01
A previous investigation on the presence of direct and indirect combustion noise for a full-scale turbofan engine using a far-field microphone at 130 is extended by also examining signals obtained at two additional downstream directions using far-field microphones at 110 deg and 160 deg. A generalized cross-correlation function technique is used to study the change in propagation time to the far field of the combined direct and indirect combustion noise signal as a sequence of low-pass filters are applied. The filtering procedure used produces no phase distortion. As the low-pass filter frequency is decreased, the travel time increases because the relative amount of direct combustion noise is reduced. The indirect combustion noise signal travels more slowly because in the combustor entropy fluctuations move with the flow velocity, which is slow compared to the local speed of sound. The indirect combustion noise signal travels at acoustic velocities after reaching the turbine and being converted into an acoustic signal. The direct combustion noise is always propagating at acoustic velocities. The results show that the estimated indirect combustion noise time delay values (post-combustion residence times) measured at each angle are fairly consistent with one another for a relevant range of operating conditions and demonstrate source separation of a mixture of direct and indirect combustion noise. The results may lead to a better idea about the acoustics in the combustor and may help develop and validate improved reduced-order physics-based methods for predicting turbofan engine core noise.
Macyszyn, Luke; Attiah, Mark; Ma, Tracy S; Ali, Zarina; Faught, Ryan; Hossain, Alisha; Man, Karen; Patel, Hiren; Sobota, Rosanna; Zager, Eric L; Stein, Sherman C
2017-05-01
OBJECTIVE Moyamoya disease (MMD) is a chronic cerebrovascular disease that can lead to devastating neurological outcomes. Surgical intervention is the definitive treatment, with direct, indirect, and combined revascularization procedures currently employed by surgeons. The optimal surgical approach, however, remains unclear. In this decision analysis, the authors compared the effectiveness of revascularization procedures in both adult and pediatric patients with MMD. METHODS A comprehensive literature search was performed for studies of MMD. Using complication and success rates from the literature, the authors constructed a decision analysis model for treatment using a direct and indirect revascularization technique. Utility values for the various outcomes and complications were extracted from the literature examining preferences in similar clinical conditions. Sensitivity analysis was performed. RESULTS A structured literature search yielded 33 studies involving 4197 cases. Cases were divided into adult and pediatric populations. These were further subdivided into 3 different treatment groups: indirect, direct, and combined revascularization procedures. In the pediatric population at 5- and 10-year follow-up, there was no significant difference between indirect and combination procedures, but both were superior to direct revascularization. In adults at 4-year follow-up, indirect was superior to direct revascularization. CONCLUSIONS In the absence of factors that dictate a specific approach, the present decision analysis suggests that direct revascularization procedures are inferior in terms of quality-adjusted life years in both adults at 4 years and children at 5 and 10 years postoperatively, respectively. These findings were statistically significant (p < 0.001 in all cases), suggesting that indirect and combination procedures may offer optimal results at long-term follow-up.
Detection of direct and indirect noise generated by synthetic hot spots in a duct
NASA Astrophysics Data System (ADS)
De Domenico, Francesca; Rolland, Erwan O.; Hochgreb, Simone
2017-04-01
Sound waves in a combustor are generated from fluctuations in the heat release rate (direct noise) or the acceleration of entropy, vorticity or compositional perturbations through nozzles or turbine guide vanes (indirect or entropy noise). These sound waves are transmitted downstream as well as reflected upstream of the acceleration point, contributing to the overall noise emissions, or triggering combustion instabilities. Previous experiments attempted to isolate indirect noise by generating thermoacoustic hot spots electrically and measuring the transmitted acoustic waves, yet there are no measurements on the backward propagating entropy and acoustic waves. This work presents the first measurements which clearly separate the direct and indirect noise contributions to pressure fluctuations upstream of the acceleration point. Synthetic entropy spots are produced by unsteady electrical heating of a grid of thin wires located in a tube. Compression waves (direct noise) are generated from this heating process. The hot spots are then advected with the mean flow and finally accelerated through an orifice plate located at the end of the tube, producing a strong acoustic signature which propagates upstream (indirect noise). The convective time is selected to be longer than the heating pulse length, in order to obtain a clear time separation between direct and indirect noise in the overall pressure trace. The contribution of indirect noise to the overall noise is shown to be non-negligible either in subsonic or sonic throat conditions. However, the absolute amplitude of direct noise is larger than the corresponding fraction of indirect noise, explaining the difficulty in clearly identifying the two contributions when they are merged. Further, the work shows the importance of using appropriate pressure transducer instrumentation and correcting for the respective transfer functions in order to account for low frequency effects in the determination of pressure fluctuations.
Gibson, Mhairi A; Gurmu, Eshetu; Cobo, Beatriz; Rueda, María M; Scott, Isabel M
2018-01-01
Female genital cutting (FGC) has major implications for women's physical, sexual and psychological health, and eliminating the practice is a key target for public health policy-makers. To date one of the main barriers to achieving this has been an inability to infer privately-held views on FGC within communities where it is prevalent. As a sensitive (and often illegal) topic, people are anticipated to hide their true support for the practice when questioned directly. Here we use an indirect questioning method (unmatched count technique) to identify hidden support for FGC in a rural South Central Ethiopian community where the practice is common, but thought to be in decline. Employing a socio-demographic household survey of 1620 Arsi Oromo adults, which incorporated both direct and indirect direct response (unmatched count) techniques we compare directly-stated versus privately-held views in support of FGC, and individual variation in responses by age, gender and education and target female (daughters versus daughters-in-law). Both genders express low support for FGC when questioned directly, while indirect methods reveal substantially higher acceptance (of cutting both daughters and daughters-in-law). Educated adults (those who have attended school) are privately more supportive of the practice than they are prepared to admit openly to an interviewer, indicating that education may heighten secrecy rather than decrease support for FGC. Older individuals hold the strongest views in favour of FGC (particularly educated older males), but they are also more inclined to conceal their support for FGC when questioned directly. As these elders represent the most influential members of society, their hidden support for FGC may constitute a pivotal barrier to eliminating the practice in this community. Our results demonstrate the great potential for indirect questioning methods to advance knowledge and inform policy on culturally-sensitive topics like FGC; providing more reliable data and improving understanding of the "true" drivers of FGC.
USDA-ARS?s Scientific Manuscript database
Background: Cattle persistently infected with Babesia bovis are reservoirs for intra- and inter-herd transmission. Since B. bovis is considered a persistent infection, developing a reliable, high-throughput assay that detects antibody during all stages of the infection could be pivotal for establish...
In Situ Detection of Macronutrients and Chloride in Seawater by Submersible Electrochemical Sensors.
Cuartero, Maria; Crespo, Gaston; Cherubini, Thomas; Pankratova, Nadezda; Confalonieri, Fabio; Massa, Francesco; Tercier-Waeber, Mary-Lou; Abdou, Melina; Schäfer, Jörg; Bakker, Eric
2018-04-03
A new submersible probe for the in situ detection of nitrate, nitrite, and chloride in seawater is presented. Inline coupling of a desalination unit, an acidification unit, and a sensing flow cell containing all-solid-state membrane electrodes allows for the potentiometric detection of nitrate and nitrite after removal of the key interfering ions in seawater, chloride and hydroxide. Thus, the electrodes exhibited attractive analytical performances for the potentiometric detection of nitrate and nitrite in desalinated and acidified seawater: fast response time ( t 95 < 12 s), excellent stability (long-term drifts of <0.5 mV h -1 ), good reproducibility (calibration parameter deviation of <3%), and satisfactory accuracy (uncertainties <8%Diff compared to reference technique). The desalination cell, which can be repetitively used for about 30 times, may additionally be used as an exhaustive, and therefore calibration-free, electrochemical sensor for chloride and indirect salinity detection. The detection of these two parameters together with nitrate and nitrite may be useful for the correlation of relative changes in macronutrient levels with salinity cycles, which is of special interest in recessed coastal water bodies. The system is capable of autonomous operation during deployment, with routines for repetitive measurements (every 2 h), data storage and management, and computer visualization of the data in real time. In situ temporal profiles observed in the Arcachon Bay (France) showed valuable environmental information concerning tide-dependent cycles of nitrate and chloride levels in the lagoon, which are here observed for the first time using direct in situ measurements. The submersible probe based on membrane electrodes presented herein may facilitate the study of biogeochemical processes occurring in marine ecosystems by the direct monitoring of nitrate and nitrite levels, which are key chemical targets in coastal waters.
Galbiati, Alessandro; Beauséjour, Christian; d'Adda di Fagagna, Fabrizio
2017-04-01
The DNA damage response (DDR) arrests cell cycle progression until DNA lesions, like DNA double-strand breaks (DSBs), are repaired. The presence of DSBs in cells is usually detected by indirect techniques that rely on the accumulation of proteins at DSBs, as part of the DDR. Such detection may be biased, as some factors and their modifications may not reflect physical DNA damage. The dependency on DDR markers of DSB detection tools has left questions unanswered. In particular, it is known that senescent cells display persistent DDR foci, that we and others have proposed to be persistent DSBs, resistant to endogenous DNA repair activities. Others have proposed that these peculiar DDR foci might not be sites of damaged DNA per se but instead stable chromatin modifications, termed DNA-SCARS. Here, we developed a method, named 'DNA damage in situ ligation followed by proximity ligation assay' (DI-PLA) for the detection and imaging of DSBs in cells. DI-PLA is based on the capture of free DNA ends in fixed cells in situ, by ligation to biotinylated double-stranded DNA oligonucleotides, which are next recognized by antibiotin anti-bodies. Detection is enhanced by PLA with a partner DDR marker at the DSB. We validated DI-PLA by demonstrating its ability to detect DSBs induced by various genotoxic insults in cultured cells and tissues. Most importantly, by DI-PLA, we demonstrated that both senescent cells in culture and tissues from aged mammals retain true unrepaired DSBs associated with DDR markers. © 2017 The Authors. Aging Cell published by the Anatomical Society and John Wiley & Sons Ltd.
Hoare, R; Thompson, K D; Herath, T; Collet, B; Bron, J E; Adams, A
2016-01-01
Infectious salmon anaemia virus (ISAV) is an orthomyxovirus that has had a significant economic impact on Atlantic salmon farming in Europe, North America and Chile. Monoclonal antibodies (mAbs) were developed against Segment 3 (encoding the viral nucleoprotein, NP) of the virus. Six of the mAbs were shown to be specific to ISAV and recognised all isolates from Scotland, Norway and Canada. They reacted with ISAV in enzyme-linked immunosorbent assay (ELISA), indirect fluorescent antibody technique (IFAT) and western blotting. They were also used to develop a novel detection method based on Luminex (Bio-Plex) bead-based flow cytometric technology for the detection of ISAV in the plasma of Atlantic salmon (Salmo salar L.) smolts experimentally infected with ISAV. Fish were challenged by intraperitoneal (i.p.) injection of virus at 50% Tissue Culture Infective Dose (TCID50) = 2.8 x106 per animal. Virus present in plasma of infected fish, collected at 0, 4, 8, 12, 16, 21 and 28 days post infection using a non-lethal sampling method (n = 12 at each time point), was quantified using the optimised Bio-Plex assay. The results obtained with this assay were compared with absolute quantification of the virus by RT-qPCR using SYBR Green I and TaqMan chemistries. The Bio-Plex assay developed using the NP mAbs appears to be a rapid, sensitive method for detecting and quantifying ISAV in small volumes of fish plasma and has the potential to be multiplexed for the detection of other fish pathogens (e.g. during co-infections). To our knowledge this is the first report of the use of Luminex (Bio-Plex) technology for the detection of a fish pathogen.
MSSM A-funnel and the galactic center excess: prospects for the LHC and direct detection experiments
Freese, Katherine; López, Alejandro; Shah, Nausheen R.; ...
2016-04-11
The pseudoscalar resonance or “A-funnel” in the Minimal Supersymmetric Standard Model (MSSM) is a widely studied framework for explaining dark matter that can yield interesting indirect detection and collider signals. The well-known Galactic Center excess (GCE) at GeV energies in the gamma ray spectrum, consistent with annihilation of a ≲ 40 GeV dark matter particle, has more recently been shown to be compatible with significantly heavier masses following reanalysis of the background.For this study, we explore the LHC and direct detection implications of interpreting the GCE in this extended mass window within the MSSM A-funnel framework. We find that compatibilitymore » with relic density, signal strength, collider constraints, and Higgs data can be simultaneously achieved with appropriate parameter choices. The compatible regions give very sharp predictions of 200-600 GeV CP-odd/even Higgs bosons at low tan β at the LHC and spin-independent cross sections ≈ 10 -11 pb at direct detection experiments. Finally, regardless of consistency with the GCE, this study serves as a useful template of the strong correlations between indirect, direct, and LHC signatures of the MSSM A-funnel region.« less
Wang, Tao; Zhang, Caixia; Cao, Xiuqin; Yang, Zhiwei
2013-12-01
To express and purify the recombinant major outer membrane protein (MOMP) of Legionella pneumophila (Lp) as diagnostic antigen, and explore its practical value in the serological diagnosis of Lp infection. The recombinant plasmid pET-momp was transformed into the E.coli BL21 competent cells. The recombinant MOMP was induced to express, and then analyzed by SDS-PAGE electrophoresis, purified by affinity chromatography. We screened and obtained 58 positive blood serum and 32 negative blood serum using the DRG (Germany, IgG/IgM/IgA) Lp kit. The blood serum samples were detected for IgG, IgM, IgA antibody levels by indirect ELISA that we had established with the purified MOMP as the coating antigen, as well as by R&D (USA, IgG/IgM/IgA) Lp kit. Then using the receiver operating characteristic (ROC) curve, we compared these two methods in the sensitivity, specificity and consistency of the test results, for evaluating the application value of the indirect ELISA of recombinant MOMP. The approximately 45 000 recombinant MOMP was successfully expressed and purified. Compared with the indirect ELISA we established with the R&D Lp kit for detecting Lp antibody IgG, IgM and IgA in blood serum, the sensitivity of the indirect ELISA of recombinant MOMP to IgG was 90.9%, the specificity was 91.7%, the Kappa value was 0.784 (P < 0.05), and the area under the ROC curve was 0.913; the sensitivity to IgM was 91.4% and the specificity was 90.6%, the Kappa value was 0.809 (P < 0.05), and the area under the ROC curve was 0.910; the sensitivity to IgA was 92.1% and the specificity was 88.9%, the Kappa value was 0.793(P < 0.05), and the area under the ROC curve was 0.905. The recombinant MOMP was successfully induced to express and purified. The indirect ELISA we established with the recombinant MOMP protein as a diagnostic antigen showed good specificity, sensitivity and consistency, which laid a foundation for the development of serological diagnosis kit of Legionnaires' disease.
Lin, Wenwen; Stoumpos, Constantinos C; Kontsevoi, Oleg Y; Liu, Zhifu; He, Yihui; Das, Sanjib; Xu, Yadong; McCall, Kyle M; Wessels, Bruce W; Kanatzidis, Mercouri G
2018-02-07
Cu 2 I 2 Se 6 is a new wide-bandgap semiconductor with high stability and great potential toward hard radiation and photon detection. Cu 2 I 2 Se 6 crystallizes in the rhombohedral R3̅m space group with a density of d = 5.287 g·cm -3 and a wide bandgap E g of 1.95 eV. First-principles electronic band structure calculations at the density functional theory level indicate an indirect bandgap and a low electron effective mass m e * of 0.32. The congruently melting compound was grown in centimeter-size Cu 2 I 2 Se 6 single crystals using a vertical Bridgman method. A high electric resistivity of ∼10 12 Ω·cm is readily achieved, and detectors made of Cu 2 I 2 Se 6 single crystals demonstrate high photosensitivity to Ag Kα X-rays (22.4 keV) and show spectroscopic performance with energy resolutions under 241 Am α-particles (5.5 MeV) radiation. The electron mobility is measured by a time-of-flight technique to be ∼46 cm 2 ·V -1 ·s -1 . This value is comparable to that of one of the leading γ-ray detector materials, TlBr, and is a factor of 30 higher than mobility values obtained for amorphous Se for X-ray detection.
Hellman, Maarit; Piirainen, Henni; Jaakola, Veli-Pekka; Permi, Perttu
2014-01-01
NMR spectroscopy is by far the most versatile and information rich technique to study intrinsically disordered proteins (IDPs). While NMR is able to offer residue level information on structure and dynamics, assignment of chemical shift resonances in IDPs is not a straightforward process. Consequently, numerous pulse sequences and assignment protocols have been developed during past several years, targeted especially for the assignment of IDPs, including experiments that employ H(N), H(α) or (13)C detection combined with two to six indirectly detected dimensions. Here we propose two new HN-detection based pulse sequences, (HCA)CON(CAN)H and (HCA)N(CA)CO(N)H, that provide correlations with (1)H(N)(i - 1), (13)C'(i - 1) and (15)N(i), and (1)H(N)(i + 1), (13)C'(i) and (15)N(i) frequencies, respectively. Most importantly, they offer sequential links across the proline bridges and enable filling the single proline gaps during the assignment. We show that the novel experiments can efficiently complement the information available from existing HNCO and intraresidual i(HCA)CO(CA)NH pulse sequences and their concomitant usage enabled >95 % assignment of backbone resonances in cytoplasmic tail of adenosine receptor A2A in comparison to 73 % complete assignment using the HNCO/i(HCA)CO(CA)NH data alone.
[Review of driver fatigue/drowsiness detection methods].
Wang, Lei; Wu, Xiaojuan; Yu, Mengsun
2007-02-01
Driver fatigue/drowsiness is one of the important causes of serious traffic accidents and results in so many people deaths or injuries, but also substantial directly and indirectly economic expenses. Therefore, many countries make great effort on how to detect drowsiness during driving. In this paper, we introduce the recent developments of driver fatigue/drowsiness detection technology of world wide and try to classify the existing methods into several kinds according to different features measured, and analyzed. Finally, the challenges faced to fatigue/drowsiness detection technology and the development trend are presented.
Nguyen, Quynh C; Osypuk, Theresa L; Schmidt, Nicole M; Glymour, M Maria; Tchetgen Tchetgen, Eric J
2015-03-01
Despite the recent flourishing of mediation analysis techniques, many modern approaches are difficult to implement or applicable to only a restricted range of regression models. This report provides practical guidance for implementing a new technique utilizing inverse odds ratio weighting (IORW) to estimate natural direct and indirect effects for mediation analyses. IORW takes advantage of the odds ratio's invariance property and condenses information on the odds ratio for the relationship between the exposure (treatment) and multiple mediators, conditional on covariates, by regressing exposure on mediators and covariates. The inverse of the covariate-adjusted exposure-mediator odds ratio association is used to weight the primary analytical regression of the outcome on treatment. The treatment coefficient in such a weighted regression estimates the natural direct effect of treatment on the outcome, and indirect effects are identified by subtracting direct effects from total effects. Weighting renders treatment and mediators independent, thereby deactivating indirect pathways of the mediators. This new mediation technique accommodates multiple discrete or continuous mediators. IORW is easily implemented and is appropriate for any standard regression model, including quantile regression and survival analysis. An empirical example is given using data from the Moving to Opportunity (1994-2002) experiment, testing whether neighborhood context mediated the effects of a housing voucher program on obesity. Relevant Stata code (StataCorp LP, College Station, Texas) is provided. © The Author 2015. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Ethylene resistance in flowering ornamental plants – improvements and future perspectives
Olsen, Andreas; Lütken, Henrik; Hegelund, Josefine Nymark; Müller, Renate
2015-01-01
Various strategies of plant breeding have been attempted in order to improve the ethylene resistance of flowering ornamental plants. These approaches span from conventional techniques such as simple cross-pollination to new breeding techniques which modify the plants genetically such as precise genome-editing. The main strategies target the ethylene pathway directly; others focus on changing the ethylene pathway indirectly via pathways that are known to be antagonistic to the ethylene pathway, e.g. increasing cytokinin levels. Many of the known elements of the ethylene pathway have been addressed experimentally with the aim of modulating the overall response of the plant to ethylene. Elements of the ethylene pathway that appear particularly promising in this respect include ethylene receptors as ETR1, and transcription factors such as EIN3. Both direct and indirect approaches seem to be successful, nevertheless, although genetic transformation using recombinant DNA has the ability to save much time in the breeding process, they are not readily used by breeders yet. This is primarily due to legislative issues, economic issues, difficulties of implementing this technology in some ornamental plants, as well as how these techniques are publically perceived, particularly in Europe. Recently, newer and more precise genome-editing techniques have become available and they are already being implemented in some crops. New breeding techniques may help change the current situation and pave the way toward a legal and public acceptance if products of these technologies are indistinguishable from plants obtained by conventional techniques. PMID:26504580
Debiasing comparative optimism and increasing worry for health outcomes.
Rose, Jason P
2012-11-01
Comparative optimism - feeling at less personal risk for negative outcomes than one's peers - has been linked to reduced prevention efforts. This study examined a novel debiasing technique aimed at simultaneously reducing both indirectly and directly measured comparative optimism. Before providing direct comparative estimates, participants provided absolute self and peer estimates in a joint format (same computer screen) or a separate format (different computer screens). Relative to the separate format condition, participants in the joint format condition showed (1) lower comparative optimism in absolute/indirect measures, (2) lower direct comparative optimism, and (3) heightened worry. Implications for risk perception screening are discussed.
Indirect Gas Species Monitoring Using Tunable Diode Lasers
Von Drasek, William A.; Saucedo, Victor M.
2005-02-22
A method for indirect gas species monitoring based on measurements of selected gas species is disclosed. In situ absorption measurements of combustion species are used for process control and optimization. The gas species accessible by near or mid-IR techniques are limited to species that absorb in this spectral region. The absorption strength is selected to be strong enough for the required sensitivity and is selected to be isolated from neighboring absorption transitions. By coupling the gas measurement with a software sensor gas, species not accessible from the near or mid-IR absorption measurement can be predicted.
[A new method of fabricating photoelastic model by rapid prototyping].
Fan, Li; Huang, Qing-feng; Zhang, Fu-qiang; Xia, Yin-pei
2011-10-01
To explore a novel method of fabricating the photoelastic model using rapid prototyping technique. A mandible model was made by rapid prototyping with computerized three-dimensional reconstruction, then the photoelastic model with teeth was fabricated by traditional impression duplicating and mould casting. The photoelastic model of mandible with teeth, which was fabricated indirectly by rapid prototyping, was very similar to the prototype in geometry and physical parameters. The model was of high optical sensibility and met the experimental requirements. Photoelastic model of mandible with teeth indirectly fabricated by rapid prototyping meets the photoelastic experimental requirements well.
Bovali, Efstathia; Kiliaridis, Stavros; Cornelis, Marie A
2014-12-01
The objective of this 2-arm parallel single-center trial was to compare placement time and numbers of failures of mandibular lingual retainers bonded with an indirect procedure vs a direct bonding procedure. Sixty-four consecutive patients at the postgraduate orthodontic clinic of the University of Geneva in Switzerland scheduled for debonding and mandibular fixed retainer placement were randomly allocated to either an indirect bonding procedure or a traditional direct bonding procedure. Eligibility criteria were the presence of the 4 mandibular incisors and the 2 mandibular canines, and no active caries, restorations, fractures, or periodontal disease of these teeth. The patients were randomized in blocks of 4; the randomization sequence was generated using an online randomization service (www.randomization.com). Allocation concealment was secured by contacting the sequence generator for treatment assignment; blinding was possible for outcome assessment only. Bonding time was measured for each procedure. Unpaired t tests were used to assess differences in time. Patients were recalled at 1, 2, 4, and 6 months after bonding. Mandibular fixed retainers having at least 1 composite pad debonded were considered as failures. The log-rank test was used to compare the Kaplan-Meier survival curves of both procedures. A test of proportion was applied to compare the failures at 6 months between the treatment groups. Sixty-four patients were randomized in a 1:1 ratio. One patient dropped out at baseline after the bonding procedure, and 3 patients did not attend the recalls at 4 and 6 months. Bonding time was significantly shorter for the indirect procedure (321 ± 31 seconds, mean ± SD) than for the direct procedure (401 ± 40 seconds) (per protocol analysis of 63 patients: mean difference = 80 seconds; 95% CI = 62.4-98.1; P <0.001). The 6-month numbers of failures were 10 of 31 (32%) with the indirect technique and 7 of 29 (24%) with the direct technique (log rank: P = 0.35; test of proportions: risk difference = 0.08; 95% CI = -0.15 to 0.31; P = 0.49). No serious harm was observed except for plaque accumulation. Indirect bonding was statistically significantly faster than direct bonding, with both techniques showing similar risks of failure. This trial was not registered. The protocol was not published before trial commencement. No funding or conflict of interest to be declared. Copyright © 2014 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Direct high-precision measurement of the magnetic moment of the proton.
Mooser, A; Ulmer, S; Blaum, K; Franke, K; Kracke, H; Leiteritz, C; Quint, W; Rodegheri, C C; Smorra, C; Walz, J
2014-05-29
One of the fundamental properties of the proton is its magnetic moment, µp. So far µp has been measured only indirectly, by analysing the spectrum of an atomic hydrogen maser in a magnetic field. Here we report the direct high-precision measurement of the magnetic moment of a single proton using the double Penning-trap technique. We drive proton-spin quantum jumps by a magnetic radio-frequency field in a Penning trap with a homogeneous magnetic field. The induced spin transitions are detected in a second trap with a strong superimposed magnetic inhomogeneity. This enables the measurement of the spin-flip probability as a function of the drive frequency. In each measurement the proton's cyclotron frequency is used to determine the magnetic field of the trap. From the normalized resonance curve, we extract the particle's magnetic moment in terms of the nuclear magneton: μp = 2.792847350(9)μN. This measurement outperforms previous Penning-trap measurements in terms of precision by a factor of about 760. It improves the precision of the forty-year-old indirect measurement, in which significant theoretical bound state corrections were required to obtain µp, by a factor of 3. By application of this method to the antiproton magnetic moment, the fractional precision of the recently reported value can be improved by a factor of at least 1,000. Combined with the present result, this will provide a stringent test of matter/antimatter symmetry with baryons.
Solid-state NMR covariance of homonuclear correlation spectra.
Hu, Bingwen; Amoureux, Jean-Paul; Trebosc, Julien; Deschamps, Michael; Tricot, Gregory
2008-04-07
Direct covariance NMR spectroscopy, which does not involve a Fourier transformation along the indirect dimension, is demonstrated to obtain homonuclear correlation two-dimensional (2D) spectra in the solid state. In contrast to the usual 2D Fourier transform (2D-FT) NMR, in a 2D covariance (2D-Cov) spectrum the spectral resolution in the indirect dimension is determined by the resolution along the detection dimension, thereby largely reducing the time-consuming indirect sampling requirement. The covariance method does not need any separate phase correction or apodization along the indirect dimension because it uses those applied in the detection dimension. We compare in detail the specifications obtained with 2D-FT and 2D-Cov, for narrow and broad resonances. The efficiency of the covariance data treatment is demonstrated in organic and inorganic samples that are both well crystallized and amorphous, for spin -1/2 nuclei with 13C, 29Si, and 31P through-space or through-bond homonuclear 2D correlation spectra. In all cases, the experimental time has been reduced by at least a factor of 10, without any loss of resolution and signal to noise ratio, with respect to what is necessary with the 2D-FT NMR. According to this method, we have been able to study the silicate network of glasses by 2D NMR within reasonable experimental time despite the very long relaxation time of the 29Si nucleus. The main limitation of the 2D-Cov data treatment is related to the introduction of autocorrelated peaks onto the diagonal, which does not represent any actual connectivity.
NASA Technical Reports Server (NTRS)
Adamovsky, Grigory; Eustace, John G.
1990-01-01
Techniques for the quantitative determination of shock position in supersonic flows using direct and indirect methods is presented. A description of an experimental setup is also presented, different configurations of shock position sensing systems are explained, and some experimental results are given. All of the methods discussed are analyzed to determine the ease of technology transfer from the laboratory to in-flight operation.
Production and characterization of egg yolk antibody (IgY) against recombinant VP8-S2 antigen.
Nasiri, K; Nassiri, M R; Tahmoorespur, M; Haghparast, A; Zibaee, S
2016-01-01
Bovine Rotavirus and Bovine Coronavirus are the most important causes of diarrhea in newborn calves and in some other species such as pigs and sheep. VP8 subunit of rotavirus is the major determinant of the viral infectivity and neutralization. Spike glycoprotein of coronavirus is responsible for induction of neutralizing antibody response. Studies showed that immunoglobulin of egg yolk (IgY) from immunized hens has been identified to be a convenient source for specific antibodies for using in immunotherapy and immunodiagnostic to limit the infections. In this study, chimeric VP8-S2 gene was designed using by computational techniques. The chimeric VP8-S2 gene was cloned and sub-cloned into pGH and pET32a (+) vectors. Then, recombinant pET32a-VP8-S2 vector was transferred into E. coli BL21 CodonPlus (DE3). The expressed protein was purified by Ni-NTA chromatography column. Hens were immunized with the purified VP8-S2 protein three times. IgY was purified from egg yolks using polyethylene glycol precipitation method. Activity and specificity of anti-VP8-S2 IgY were detected by dot-blotting, Western-blotting and indirect ELISA. We obtained anti-VP8-S2 IgY by immunizing hens with the recombinant VP8-S2 protein. The anti-VP8-S2 IgY was showed to bind specifically to the chimeric VP8-S2 protein by dot-blotting, Western-blotting analyses and indirect ELISA. The result of this study indicated that such construction can be useful to investigate as candidates for development of detection methods for simultaneous diagnosis of both infections. Specific IgY against the recombinant VP8-S2 could be recommended as a candidate for passive immunization against bovine rotavirus and bovine coronavirus.
Is Seeing Believing?: Observation in Physics
NASA Astrophysics Data System (ADS)
Franklin, Allan David
2017-12-01
In 2016 the LIGO-Virgo collaboration announced "the first direct detection of gravitational waves." This was to distinguish their result from the indirect observation of Russell Hulse, Joel Weisberg, and Joseph Taylor, which used the decrease in the period of a binary pulsar to "establish, with a high degree of confidence the existence of gravitational radiation as predicted by general relativity." This raises several interesting questions. One might ask how one can distinguish between direct and indirect observation and whether that distinction is exemplified in the practice of science. One might also ask whether a direct observation has more epistemic weight than an indirect observation. In this essay, I briefly discuss several episodes from the history of modern physics in an attempt to answer those questions. These episodes include Galileo and falling bodies, the discovery of the neutrino, the Higgs boson, and gravitational radiation.