Kim, Un-Jung; Kim, Hee Young; Alvarez, David A.; Lee, In-Seok; Oh, Jeong-Eun
2014-01-01
We aimed to verify the effectiveness of semi-permeablemembrane devices (SPMDs) formonitoring hydrophobic organic compounds, such as polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs), that are not easy to detect using conventional grab samples (because of their low concentrations), in water.We used SPMDs and grab samples to monitor PCBs and PBDEs upstream and downstream of a sewage treatment plant (STP) in the Suyeong River in Busan, Korea. Concentrations in three different phases (freely dissolved, apparently dissolved, and particulate) were measured, to investigate the aquatic fate of PCBs and PBDEs. The freely dissolved (SPMD) concentrations were 2–3 times higher than the apparently dissolved and particulate phase (grab sample) concentrations. No meaningful relationships were found between the total PCB and PBDE concentrations of the grab sample and SPMD sample because of the different partitioning behaviors and detection frequencies of the individual chemicals. However, the summed concentrations of specific PCB and PBDE congeners (that were abundant in all samples) in the grab and SPMD samples correlated well (r2 = 0.7451 for PCBs 28 + 52 + 153, r2 = 0.9987 for PBDEs 28 + 47 + 99). The PBDE concentrations measured using SPMDs decreased with increasing distance from the STP, but no apparent dilution effect was found in the grab samples. Our results show that SPMDs could be used to support grab sampling for specific chemicals, or to trace chemical sources (such as STPs) to the aquatic environment.
Stade, Björn; Seelow, Dominik; Thomsen, Ingo; Krawczak, Michael; Franke, Andre
2014-01-01
Next Generation Sequencing (NGS) of whole exomes or genomes is increasingly being used in human genetic research and diagnostics. Sharing NGS data with third parties can help physicians and researchers to identify causative or predisposing mutations for a specific sample of interest more efficiently. In many cases, however, the exchange of such data may collide with data privacy regulations. GrabBlur is a newly developed tool to aggregate and share NGS-derived single nucleotide variant (SNV) data in a public database, keeping individual samples unidentifiable. In contrast to other currently existing SNV databases, GrabBlur includes phenotypic information and contact details of the submitter of a given database entry. By means of GrabBlur human geneticists can securely and easily share SNV data from resequencing projects. GrabBlur can ease the interpretation of SNV data by offering basic annotations, genotype frequencies and in particular phenotypic information - given that this information was shared - for the SNV of interest. GrabBlur facilitates the combination of phenotypic and NGS data (VCF files) via a local interface or command line operations. Data submissions may include HPO (Human Phenotype Ontology) terms, other trait descriptions, NGS technology information and the identity of the submitter. Most of this information is optional and its provision at the discretion of the submitter. Upon initial intake, GrabBlur merges and aggregates all sample-specific data. If a certain SNV is rare, the sample-specific information is replaced with the submitter identity. Generally, all data in GrabBlur are highly aggregated so that they can be shared with others while ensuring maximum privacy. Thus, it is impossible to reconstruct complete exomes or genomes from the database or to re-identify single individuals. After the individual information has been sufficiently "blurred", the data can be uploaded into a publicly accessible domain where aggregated genotypes are provided alongside phenotypic information. A web interface allows querying the database and the extraction of gene-wise SNV information. If an interesting SNV is found, the interrogator can get in contact with the submitter to exchange further information on the carrier and clarify, for example, whether the latter's phenotype matches with phenotype of their own patient.
GY SAMPLING THEORY IN ENVIRONMENTAL STUDIES 1: ASSESSING SOIL SPLITTING PROTOCOLS
Five soil sample splitting methods (riffle splitting, paper cone riffle splitting, fractional shoveling, coning and quartering, and grab sampling) were evaluated with synthetic samples to verify Pierre Gy sampling theory expectations. Individually prepared samples consisting of l...
Krempa, Heather M.
2015-10-29
Relative percent differences between methods were greater than 10 percent for most analyzed trace elements. Barium, cobalt, manganese, and boron had concentrations that were significantly different between sampling methods. Barium, molybdenum, boron, and uranium method concentrations indicate a close association between pump and grab samples based on bivariate plots and simple linear regressions. Grab sample concentrations were generally larger than pump concentrations for these elements and may be because of using a larger pore sized filter for grab samples. Analysis of zinc blank samples suggests zinc contamination in filtered grab samples. Variations of analyzed trace elements between pump and grab samples could reduce the ability to monitor temporal changes and potential groundwater contamination threats. The degree of precision necessary for monitoring potential groundwater threats and application objectives need to be considered when determining acceptable variation amounts.
NASA Astrophysics Data System (ADS)
Lucas, Andrew R.; Salmon, S. Ursula; Rate, Andrew W.; Larsen, Sarah; Kilminster, Kieryn
2015-12-01
This study reports the first surface water evaluation of the temporal and spatial variability of Au in an estuary, using recently developed modifications to the diffusive gradients in thin films (DGT) and grab sampling techniques. At the two study sites in the Swan River estuary that were more marine in character, the DGT-measured concentrations of Au (26.3 and 31.3 ng/L) were within the range of total concentrations measured on individual days (13.2-30.6 ng/L and 11.2-37.2 ng/L, respectively). In contrast, at an upstream site, Au concentrations measured by DGT were significantly lower than totals (3.9 ng/L for DGT, compared with 13.2-28.8 ng/L for grab sampling), likely due to either size exclusion of colloids (>70 nm) by DGT or formation of a dissolved, non-DGT-labile Au species (<0.45 μm). DGT-measured concentrations of other metals (Cu, Co, Cr, U, V, Mo and As) were also lower than total concentrations, although in contrast to DGT-measured Au, this phenomenon occurred at all sites. Furthermore, daily grab samples for Au, taken over the 10-day deployment (which included a rain event), showed that Au concentrations could spike substantially (from 15.1 ng/L to 37.2 ng/L) over intervals as short as one day. The combination of simultaneous deployment of different DGT devices and grab sampling represents a new development in efforts to understand the transport and fate of Au together with other elements in dynamic environments such as estuaries.
Mass load estimation errors utilizing grab sampling strategies in a karst watershed
Fogle, A.W.; Taraba, J.L.; Dinger, J.S.
2003-01-01
Developing a mass load estimation method appropriate for a given stream and constituent is difficult due to inconsistencies in hydrologic and constituent characteristics. The difficulty may be increased in flashy flow conditions such as karst. Many projects undertaken are constrained by budget and manpower and do not have the luxury of sophisticated sampling strategies. The objectives of this study were to: (1) examine two grab sampling strategies with varying sampling intervals and determine the error in mass load estimates, and (2) determine the error that can be expected when a grab sample is collected at a time of day when the diurnal variation is most divergent from the daily mean. Results show grab sampling with continuous flow to be a viable data collection method for estimating mass load in the study watershed. Comparing weekly, biweekly, and monthly grab sampling, monthly sampling produces the best results with this method. However, the time of day the sample is collected is important. Failure to account for diurnal variability when collecting a grab sample may produce unacceptable error in mass load estimates. The best time to collect a sample is when the diurnal cycle is nearest the daily mean.
Contaminants in landfill soils - Reliability of prefeasibility studies.
Hölzle, Ingo
2017-05-01
Recent landfill mining studies have researched the potential for resource recovery using samples from core drilling or grab cranes. However, most studies used small sample numbers, which may not represent the heterogeneous landfill composition. As a consequence, there exists a high risk of an incorrect economic and/or ecological evaluation. The main objective of this work is to investigate the possibilities and limitations of preliminary investigations concerning the crucial soil composition. The preliminary samples of landfill investigations were compared to the excavation samples from three completely excavated landfills in Germany. In addition, the research compared the reliability of prediction of the two investigation methods, core drilling and grab crane. Sampling using a grab crane led to better results, even for smaller investigations of 10 samples. Analyses of both methods showed sufficiently accurate results to make predictions (standard error 5%, level of confidence 95%) for most heavy metals, cyanide and PAH in the dry substance and for sulphate, barium, Benzo[a]pyrene, pH and the electrical conductivity in leachate analyses of soil type waste. While chrome and nickel showed less accurate results, the concentrations of hydrocarbons, TOC, DOC, PCB and fluorine (leachate) were not predictable even for sample numbers of up to 59. Overestimations of pollutant concentrations were more frequently apparent in drilling, and underestimations when using a grab crane. The dispersion of the element and elemental composition had no direct impact on the reliability of prediction. Thus, an individual consideration of the particular element or elemental composition for dry substance and leachate analyses is recommended to adapt the sample strategy and calculate an optimum sample number. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
BELL, K.E.
This document is the format IV, final report for the tank 241-SY-102 (SY-102) grab samples taken in January 2000 to address waste compatibility concerns. Chemical, radiochemical, and physical analyses on the tank SY-102 samples were performed as directed in Comparability Grab Sampling and Analysis Plan for Fiscal Year 2000 (Sasaki 1999). No notification limits were exceeded. Preliminary data on samples 2SY-99-5, -6, and -7 were reported in ''Format II Report on Tank 241-SY-102 Waste Compatibility Grab Samples Taken in January 2000'' (Lockrem 2000). The data presented here represent the final results.
Monitoring for contaminants of emerging concern in drinking water using POCIS passive samplers.
Metcalfe, Chris; Hoque, M Ehsanul; Sultana, Tamanna; Murray, Craig; Helm, Paul; Kleywegt, Sonya
2014-03-01
Contaminants of emerging concern (CEC) have been detected in drinking water world-wide. The source of most of these compounds is generally attributed to contamination from municipal wastewater. Traditional water sampling methods (grab or composite) often require the concentration of large amounts of water in order to detect trace levels of these contaminants. The Polar Organic Compounds Integrative Sampler (POCIS) is a passive sampling technology that has been developed to concentrate trace levels of CEC to provide time-weighted average concentrations for individual compounds in water. However, few studies to date have evaluated whether POCIS is suitable for monitoring contaminants in drinking water. In this study, the POCIS was evaluated as a monitoring tool for CEC in drinking water over a period of 2 and 4 weeks with comparisons to typical grab samples. Seven "indicator compounds" which included carbamazepine, trimethoprim, sulfamethoxazole, ibuprofen, gemfibrozil, estrone and sucralose, were monitored in five drinking water treatment plants (DWTPs) in Ontario. All indicator compounds were detected in raw water samples from the POCIS in comparison to six from grab samples. Similarly, four compounds were detected in grab samples of treated drinking water, whereas six were detected in the POCIS. Sucralose was the only compound that was detected consistently at all five plants. The POCIS technique provided integrative exposures of CECs in drinking water at lower detection limits, while episodic events were captured via traditional sampling methods. There was evidence that the accumulation of target compounds by POCIS is a dynamic process, with adsorption and desorption on the sorbent occurring in response to ambient levels of the target compounds in water. CECs in treated drinking water were present at low ng L(-1) concentrations, which are not considered to be a threat to human health.
Comparability of river suspended-sediment sampling and laboratory analysis methods
Groten, Joel T.; Johnson, Gregory D.
2018-03-06
Accurate measurements of suspended sediment, a leading water-quality impairment in many Minnesota rivers, are important for managing and protecting water resources; however, water-quality standards for suspended sediment in Minnesota are based on grab field sampling and total suspended solids (TSS) laboratory analysis methods that have underrepresented concentrations of suspended sediment in rivers compared to U.S. Geological Survey equal-width-increment or equal-discharge-increment (EWDI) field sampling and suspended sediment concentration (SSC) laboratory analysis methods. Because of this underrepresentation, the U.S. Geological Survey, in collaboration with the Minnesota Pollution Control Agency, collected concurrent grab and EWDI samples at eight sites to compare results obtained using different combinations of field sampling and laboratory analysis methods.Study results determined that grab field sampling and TSS laboratory analysis results were biased substantially low compared to EWDI sampling and SSC laboratory analysis results, respectively. Differences in both field sampling and laboratory analysis methods caused grab and TSS methods to be biased substantially low. The difference in laboratory analysis methods was slightly greater than field sampling methods.Sand-sized particles had a strong effect on the comparability of the field sampling and laboratory analysis methods. These results indicated that grab field sampling and TSS laboratory analysis methods fail to capture most of the sand being transported by the stream. The results indicate there is less of a difference among samples collected with grab field sampling and analyzed for TSS and concentration of fines in SSC. Even though differences are present, the presence of strong correlations between SSC and TSS concentrations provides the opportunity to develop site specific relations to address transport processes not captured by grab field sampling and TSS laboratory analysis methods.
Estimating means and variances: The comparative efficiency of composite and grab samples.
Brumelle, S; Nemetz, P; Casey, D
1984-03-01
This paper compares the efficiencies of two sampling techniques for estimating a population mean and variance. One procedure, called grab sampling, consists of collecting and analyzing one sample per period. The second procedure, called composite sampling, collectsn samples per period which are then pooled and analyzed as a single sample. We review the well known fact that composite sampling provides a superior estimate of the mean. However, it is somewhat surprising that composite sampling does not always generate a more efficient estimate of the variance. For populations with platykurtic distributions, grab sampling gives a more efficient estimate of the variance, whereas composite sampling is better for leptokurtic distributions. These conditions on kurtosis can be related to peakedness and skewness. For example, a necessary condition for composite sampling to provide a more efficient estimate of the variance is that the population density function evaluated at the mean (i.e.f(μ)) be greater than[Formula: see text]. If[Formula: see text], then a grab sample is more efficient. In spite of this result, however, composite sampling does provide a smaller estimate of standard error than does grab sampling in the context of estimating population means.
Clausen, J L; Georgian, T; Gardner, K H; Douglas, T A
2018-01-01
This study compares conventional grab sampling to incremental sampling methodology (ISM) to characterize metal contamination at a military small-arms-range. Grab sample results had large variances, positively skewed non-normal distributions, extreme outliers, and poor agreement between duplicate samples even when samples were co-located within tens of centimeters of each other. The extreme outliers strongly influenced the grab sample means for the primary contaminants lead (Pb) and antinomy (Sb). In contrast, median and mean metal concentrations were similar for the ISM samples. ISM significantly reduced measurement uncertainty of estimates of the mean, increasing data quality (e.g., for environmental risk assessments) with fewer samples (e.g., decreasing total project costs). Based on Monte Carlo resampling simulations, grab sampling resulted in highly variable means and upper confidence limits of the mean relative to ISM.
Tank 241-U-103, grab samples 3U-99-1, 3u-99-2 and 3U-99-3
DOE Office of Scientific and Technical Information (OSTI.GOV)
STEEN, F.H.
This document is the final report for tank 241-U-103 grab samples. Three grab samples were collected from riser 13 on March 12, 1999 and received by the 222-S laboratory on March 15, 1999. Analyses were performed in accordance with the Compatibility Grab Sampling and Analysis Plan for Fiscal year 1999 (TSAP) and the Data Quality Objectives for Tank Farms Waste Compatibility Program (DQO). The analytical results are presented in the data summary report. None of the subsamples submitted for differential scanning calorimetry (DSC), total organic carbon (TOC) and plutonium 239 (Pu239) analyses exceeded the notification limits as stated in TSAP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
FULLER, R.K.
1999-02-24
This document is the final report for tank 241-AN-101 grab samples. Three grab samples 1AN-98-1, 1AN-98-2 and 1AN-98-3 were taken from riser 16 of tank 241-AN-101 on April 8, 1998 and received by the 222-S Laboratory on April 9, 1998. Analyses were performed in accordance with the ''Compatability Grab Sampling and Analysis Plan'' (TSAP) and the ''Data Quality Objectives for Tank Farms Waste Compatability Program'' (DQO). The analytical results are presented in the data summary report. No notification limits were exceeded.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wyrwas, Richard B.; Lamothe, Margaret E.
2013-05-30
This report describes the results of the electrochemical testing performed on tank 241-SY-102 (SY-102) grab samples that were collected in support of corrosion mitigation. The objective of the work presented here was to determine corrosion resistance of tank SY-102 to the grab samples collected using electrochemical methods up to 50°C as well as to satisfy data quality objectives. Grab samples were collected at multiple elevations from Riser 003. The electrochemical corrosion testing was planned to consist of linear polarization resistance testing (LPR) and cyclic potentiodynamic polarization (CPP) testing at 50°C. The temperature would be lowered to 40 °C and themore » test repeated if the CPP curve indicated pitting corrosion at 50°C. Ifno pitting was indicated by the CPP curve, then a duplicate scan would be repeated at 50°C to confirm the first result. The testing would be complete if the duplicate CPP scan was consistent with the first. This report contains the CPP results of the testing of grab sample 2SY-12-03 and 2SY-12-03DUP composite sample tested under these conditions. There was no indication of pitting at 50°C, and the duplicate scan was in agreement with the first scan. Since no further testing was required, a third scan with a shorter rest time was performed and is present in this report.« less
1989 Intercomparison of radon progeny measurement methods and equipment in North America
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scofield, P.; George, A.; Tu, Keng.
1990-03-01
At the 1989 {sup 222}Rn progeny intercomparison held at the Environmental Measurements Laboratory (EML), July 10--14, 1989, grab sampling and integrating/continuous {sup 222}Rn progeny methods were evaluated. Sixteen facilities participated in this intercomparison. Twelve facilities used {sup 222}Rn progeny grab sampling methods, and nine facilities used integrating/continuous instruments. Eighty-eight percent of the participants reported grab sample {sup 222}Rn progeny concentrations that were within 20% of the EML reference values. Good agreement between participant and EML grab-sample potential alpha energy concentrations (PAECs) was observed; 92% of the participants had PAECs within 20% of the EML values. For the integrating/continuous PAEC valuesmore » determined with integrating/continuous monitors, 89% of the participants were within 20% of the EML reference values. 9 refs., 3 figs., 4 tabs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
FULLER, R.K.
1999-02-23
This document is the final report for tank 241-AP-106 grab samples. Three grab samples 6AP-98-1, 6AP-98-2 and 6AP-98-3 were taken from riser 1 of tank 241-AP-106 on May 28, 1998 and received by the 222-S Laboratory on May 28, 1998. Analyses were performed in accordance with the ''Compatability Grab Sampling and Analysis Plan'' (TSAP) (Sasaki, 1998) and the ''Data Quality Objectives for Tank Farms Waste Compatability Program (DQO). The analytical results are presented in the data summary report. No notification limits were exceeded. The request for sample analysis received for AP-106 indicated that the samples were polychlorinated biphenyl (PCB) suspects.more » The results of this analysis indicated that no PCBs were present at the Toxic Substance Control Act (TSCA) regulated limit of 50 ppm. The results and raw data for the PCB analysis are included in this document.« less
Clausen, J L; Georgian, T; Gardner, K H; Douglas, T A
2018-01-01
Research shows grab sampling is inadequate for evaluating military ranges contaminated with energetics because of their highly heterogeneous distribution. Similar studies assessing the heterogeneous distribution of metals at small-arms ranges (SAR) are lacking. To address this we evaluated whether grab sampling provides appropriate data for performing risk analysis at metal-contaminated SARs characterized with 30-48 grab samples. We evaluated the extractable metal content of Cu, Pb, Sb, and Zn of the field data using a Monte Carlo random resampling with replacement (bootstrapping) simulation approach. Results indicate the 95% confidence interval of the mean for Pb (432 mg/kg) at one site was 200-700 mg/kg with a data range of 5-4500 mg/kg. Considering the U.S. Environmental Protection Agency screening level for lead is 400 mg/kg, the necessity of cleanup at this site is unclear. Resampling based on populations of 7 and 15 samples, a sample size more realistic for the area yielded high false negative rates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
STEEN, F.H.
This document is the format IV, final report for the tank 241-S-111 (S-111) grab samples taken in August 1999 to address waste compatibility concerns. Chemical, radiochemical, and physical analyses on the tank S-111 samples were performed as directed in Compatibility Grab Sampling and Analysis Plan for Fiscal Year 1999 (Sasaki 1999a,b). Any deviations from the instructions provided in the tank sampling and analysis plan (TSAP) were discussed in this narrative. The notification limit for {sup 137}Cs was exceeded on two samples. Results are discussed in Section 5.3.2. No other notification limits were exceeded.
USDA-ARS?s Scientific Manuscript database
Tailwater recovery (TWR) systems are being implemented on agricultural landscapes to create an additional source of irrigation water. Existing studies have sampled TWR systems using grab samples; however, the applicability of solids and nutrient concentrations in these samples to water being irrigat...
Berton, André; Brugnera, Michelle F; Dores, Eliana F G C
2018-04-03
In this study, the quality of surface water in the headwaters of São Lourenço River in Mato Grosso, Brazil, was evaluated in relation to contamination by pesticides. For this purpose, samples were collected between December 2015 and June 2016 by grab sampling and by passive sampling using an integrative polar organic compound sampler installed in the field during four 14-day cycles between March and June 2016. The analyses were performed by gas chromatography (CG/MS) and by liquid chromatography (UPLC-MS/MS). The results showed the detection of two pesticides (atrazine and pyraclostrobin) of the five analyzed by passive sampling and eight active principles among the 20 analyzed (malathion, diuron, carbofuran, carbendazim, trifluralin, imidacloprid, metolachlor, and acetamiprid) by grab sampling. The detection of 10 pesticides, even almost a decade after the beginning of a recovery process of the ciliary forest, confirms the headwaters' vulnerability to these contaminants and passive sampling proved to be an important tool in capturing small concentrations of pesticides constituting an interesting complement to grab sampling.
Solid Phase Characterization of Tank 241-C-105 Grab Samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ely, T. M.; LaMothe, M. E.; Lachut, J. S.
The solid phase characterization (SPC) of three grab samples from single-shell Tank 241-C-105 (C-105) that were received at the laboratory the week of October 26, 2015, has been completed. The three samples were received and broken down in the 11A hot cells.
Pettit uses a Grab Sample Container in the FGB during Expedition Six
2003-01-22
ISS006-E-20835 (22 January 2003) --- Astronaut Donald R. Pettit, Expedition 6 NASA ISS science officer, holds a Grab Sample Container (GSC) in the functional cargo block (FGB), or Zarya, on the International Space Station (ISS). GSC is used for collecting air samples as part of ISS environmental monitoring.
Pettit uses a Grab Sample Container in the U.S. Laboratory during Expedition Six
2003-01-22
ISS006-E-20834 (22 January 2003) --- Astronaut Donald R. Pettit, Expedition Six NASA ISS science officer, holds a Grab Sample Container (GSC) in the Destiny laboratory on the International Space Station (ISS). GSC is used for collecting air samples as part of ISS environmental monitoring.
Onufrienko holds a Grab Sample Container (GSC) in the SM during Expedition Four
2002-05-23
ISS004-E-12368 (23 May 2002) --- Cosmonaut Yury I. Onufrienko, Expedition Four mission commander representing Rosaviakosmos, holds a Grab Sample Container (GSC) in the Zvezda Service Module on the International Space Station (ISS). The GSC is used to take air samples in various modules as part of environmental quality control.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Stripped Resin and Process Wastewater 9 Table 9 to Subpart HHHHHHH of Part 63 Protection of Environment... Wastewater For demonstrating . . . For the following emission points and types of processes . . . Collect.... Each process wastewater stream 3. Initial compliance N/A 1 grab sample 1 grab sample. 4. Continuous...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Stripped Resin and Process Wastewater 9 Table 9 to Subpart HHHHHHH of Part 63 Protection of Environment... Wastewater For demonstrating . . . For the following emission points and types of processes . . . Collect.... Each process wastewater stream 3. Initial compliance N/A 1 grab sample 1 grab sample. 4. Continuous...
The document is a recommended operating procedure, prepare or use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The procedure applies to the collection of gaseous grab samples from fossil fuel combustion sources for subsequent a...
NASA Astrophysics Data System (ADS)
Shupp, Aaron M.; Rodier, Dan; Rowley, Steven
2007-03-01
Monitoring and controlling Airborne Molecular Contamination (AMC) has become essential in deep ultraviolet (DUV) photolithography for both optimizing yields and protecting tool optics. A variety of technologies have been employed for both real-time and grab-sample monitoring. Real-time monitoring has the advantage of quickly identifying "spikes" and upset conditions, while 2 - 24 hour plus grab sampling allows for extremely low detection limits by concentrating the mass of the target contaminant over a period of time. Employing a combination of both monitoring techniques affords the highest degree of control, lowest detection limits, and the most detailed data possible in terms of speciation. As happens with many technologies, there can be concern regarding the accuracy and agreement between real-time and grab-sample methods. This study utilizes side by side comparisons of two different real-time monitors operating in parallel with both liquid impingers and dry sorbent tubes to measure NIST traceable gas standards as well as real world samples. By measuring in parallel, a truly valid comparison is made between methods while verifying the results against a certified standard. The final outcome for this investigation is that a dry sorbent tube grab-sample technique produced results that agreed in terms of accuracy with NIST traceable standards as well as the two real-time techniques Ion Mobility Spectrometry (IMS) and Pulsed Fluorescence Detection (PFD) while a traditional liquid impinger technique showed discrepancies.
Diwan, Vishal; Stålsby Lundborg, Cecilia; Tamhankar, Ashok J
2013-01-01
The presence of antibiotics in the environment and their subsequent impact on resistance development has raised concerns globally. Hospitals are a major source of antibiotics released into the environment. To reduce these residues, research to improve knowledge of the dynamics of antibiotic release from hospitals is essential. Therefore, we undertook a study to estimate seasonal and temporal variation in antibiotic release from two hospitals in India over a period of two years. For this, 6 sampling sessions of 24 hours each were conducted in the three prominent seasons of India, at all wastewater outlets of the two hospitals, using continuous and grab sampling methods. An in-house wastewater sampler was designed for continuous sampling. Eight antibiotics from four major antibiotic groups were selected for the study. To understand the temporal pattern of antibiotic release, each of the 24-hour sessions were divided in three sub-sampling sessions of 8 hours each. Solid phase extraction followed by liquid chromatography/tandem mass spectrometry (LC-MS/MS) was used to determine the antibiotic residues. Six of the eight antibiotics studied were detected in the wastewater samples. Both continuous and grab sampling methods indicated that the highest quantities of fluoroquinolones were released in winter followed by the rainy season and the summer. No temporal pattern in antibiotic release was detected. In general, in a common timeframe, continuous sampling showed less concentration of antibiotics in wastewater as compared to grab sampling. It is suggested that continuous sampling should be the method of choice as grab sampling gives erroneous results, it being indicative of the quantities of antibiotics present in wastewater only at the time of sampling. Based on our studies, calculations indicate that from hospitals in India, an estimated 89, 1 and 25 ng/L/day of fluroquinolones, metronidazole and sulfamethoxazole respectively, might be getting released into the environment per 100 hospital beds.
Storm-Generated Sediment Distribution Along the Northwest Florida Inner Continental Shelf
2009-10-04
grain shape, direct shear, radiocarbon isotope, and lignin -phenol analyses were performed on grab or vibracore samples collected after the storm...near-shore continental shelf. 15. SUBJECT TERMS Lignin , seafloor imagery, sedimentation, sediments 16. SECURITY CLASSIFICATION OF: a. REPORT...direct shear, radiocarbon isotope, and lignin -phenol analyses were performed on grab or vibracore samples collected after the storm. Sonar
Soyuz 24 Return Samples: Assessment of Air Quality Aboard the International Space Station
NASA Technical Reports Server (NTRS)
James, John T.
2011-01-01
Fifteen mini-grab sample containers (m-GSCs) were returned aboard Soyuz. This is the first time all samples were acquired with the mini-grab samplers. The toxicological assessment of 15 m-GSCs from the ISS is shown. The recoveries of the 3 internal standards, C(13)-acetone, fluorobenzene, and chlorobenzene, from the GSCs averaged 75, 97 and 79%, respectively. Formaldehyde badges were not returned on Soyuz 24
Tank 241-AP-103 08/1999 Compatibility Grab Samples and Analytical Results for the Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
BELL, K.E.
1999-12-09
This document is the format IV, final report for the tank 241-AP-103 (AP-103) grab samples taken in August 1999 to address waste compatibility concerns. Chemical, radiochemical, and physical analyses on the tank AP-103 samples were performed as directed in ''Compatibility Grub Sampling and Analysis Plan for Fiscal Year 1999'' (Sasaki 1999a). Any deviations from the instructions provided in the tank sampling and analysis plan (TSAP) were discussed in this narrative. No notification limits were exceeded.
Comparison of four sampling methods for the detection of Salmonella in broiler litter.
Buhr, R J; Richardson, L J; Cason, J A; Cox, N A; Fairchild, B D
2007-01-01
Experiments were conducted to compare litter sampling methods for the detection of Salmonella. In experiment 1, chicks were challenged orally with a suspension of naladixic acid-resistant Salmonella and wing banded, and additional nonchallenged chicks were placed into each of 2 challenge pens. Nonchallenged chicks were placed into each nonchallenge pen located adjacent to the challenge pens. At 7, 8, 10, and 11 wk of age the litter was sampled using 4 methods: fecal droppings, litter grab, drag swab, and sock. For the challenge pens, Salmonella-positive samples were detected in 3 of 16 fecal samples, 6 of 16 litter grab samples, 7 of 16 drag swabs samples, and 7 of 16 sock samples. Samples from the nonchallenge pens were Salmonella positive in 2 of 16 litter grab samples, 9 of 16 drag swab samples, and 9 of 16 sock samples. In experiment 2, chicks were challenged with Salmonella, and the litter in the challenge and adjacent nonchallenge pens were sampled at 4, 6, and 8 wk of age with broilers remaining in all pens. For the challenge pens, Salmonella was detected in 10 of 36 fecal samples, 20 of 36 litter grab samples, 14 of 36 drag swab samples, and 26 of 36 sock samples. Samples from the adjacent nonchallenge pens were positive for Salmonella in 6 of 36 fecal droppings samples, 4 of 36 litter grab samples, 7 of 36 drag swab samples, and 19 of 36 sock samples. Sock samples had the highest rates of Salmonella detection. In experiment 3, the litter from a Salmonella-challenged flock was sampled at 7, 8, and 9 wk by socks and drag swabs. In addition, comparisons with drag swabs that were stepped on during sampling were made. Both socks (24 of 36, 67%) and drag swabs that were stepped on (25 of 36, 69%) showed significantly more Salmonella-positive samples than the traditional drag swab method (16 of 36, 44%). Drag swabs that were stepped on had comparable Salmonella detection level to that for socks. Litter sampling methods that incorporate stepping on the sample material while in contact with the litter appear to detect Salmonella in greater incidence than traditional sampling methods of dragging swabs over the litter surface.
Lietz, Arthur C.
1999-01-01
Biscayne Bay is an oligotrophic, subtropical estuary located along the southeastern coast of Florida that provides habitat for a variety of plant and animal life. Concern has arisen with regard to the ecological health of Biscayne Bay because of the presence of nutrient-laden discharges from the east coast canals that drain into the bay. This concern, as well as planned diversion of discharges for ecosystem restoration from the urban and agricultural corridors of Miami-Dade County to Everglades National Park, served as the impetus for a study conducted during the 1996 and 1997 water years to estimate nutrient loads discharged from the east coast canals into Biscayne Bay. Analytical results indicated that the highest concentration of any individual nutrient sampled for in the study was 4.38 mg/L (milligrams per liter) for nitrate at one site, and the lowest concentrations determined were below the detection limits for orthophosphate at six sites and nitrite at four sites. Median concentrations for all the sites were 0.75 mg/L for total organic nitrogen, 0.10 mg/L for ammonia, 0.02 mg/L for nitrite, 0.18 mg/L for nitrate, 0.20 mg/L for nitrite plus nitrate nitrogen, 0.02 mg/L for total phosphorus, and 0.005 mg/L for orthophosphate. The maximum total phosphorus concentration of 0.31 mg/L was the only nutrient concentration to exceed U.S. Environmental Protection Agency (1986) water-quality criteria. High concentrations of total phosphorus usually reflect contamination as a result of human activities. Five sites exceeded the fresh-water quality standard of 0.5 mg/L for ammonia concentration as determined by the Miami-Dade County Department of Environmental Resources Management. Median total organic nitrogen concentrations were higher in urban and forested/wetland areas than in agricultural areas; median concentrations of nitrite, nitrate, and nitrite plus nitrate nitrogen were higher in agricultural areas than in urban and forested/wetland areas; and ammonia, total phosphorus, and orthophosphate concentrations were higher in urban areas than in agricultural and forested/wetland areas. These results coincide with expected differences in nutrient concentrations based on knowledge of point and nonpoint source influences and nutrient cycling. The Wilcoxon signed ranks test (WSRT) was used to compare differences between point (grab) samples and depth-integrated samples for total nitrogen and total phosphorus concentrations at 12 east coast canal sites. Statistically significant differences (alpha level of 0.025) in total phosphorus concentrations between point (grab) samples collected 1.0 meter deep and depth-integrated samples were detected at three sites. One site also showed statistically significant differences in total phosphorus concentrations between point (grab) samples collected 0.5 meter deep and depth-integrated samples. There were no statistically significant differences in total nitrogen and total phosphorus concentrations between point (grab) samples collected 0.5 meter deep and 1.0 meter deep for all the sites. Results of the line of organic correlation, a fitting procedure used to compare point (grab) and depth-integrated samples where statistically significant differences exist as defined by the WSRT, indicated that point (grab) samples underestimate total phosphorus concentrations when compared to depth-integrated samples. This underestimation probably can be attributed to the reduced suspended-sediment concentrations near the surface during periods of flow as compared to those near the streambed. Predictive models were developed to estimate total nitrogen and total phosphorus loads by means of an ordinary least-squares regression technique. Instantaneous discharge was used as the independent variable, and total phosphorus load or total nitrogen load represented the dependent variable. A software program called Estimator was used to develop the regression models and to compute total nitrogen and total phosphorus loads
1997-01-01
Not Sampled f PJ)ll PARSONS SAA - Some As Above Y Water level drilled LF-JENGINEERING SCIENCE.INC. Denver, Colorado L:\\45021\\,DRAWINGS\\BORELOGS\\OT-24...Remnediotion TS TOC - Top of Cosing G - GRAB MacDill Air Force Base, Florida NS- Not Sampled .PARUONU SAA - Same As Above VWater level drilled L!LJ...GRAB MacDill Air Force Base. Florida NS - Not Sampled fj•--PAMMMNuI SAA - Some As Above Y Water level drilled *NIIN I N Denver. Colorado L:\\45021
Final report for tank 241-AP-108, grab samples 8AP-96-1, 8AP-96-2 and 8AP-96-FB
DOE Office of Scientific and Technical Information (OSTI.GOV)
Esch, R.A.
1996-04-19
This document is the final report deliverable for the tank 241-AP-108 grab samples. The samples were subsampled and analyzed in accordance with the TSAP. Included in this report are the results for the Waste Compatibility analyses, with the exception of DSC and thermogravimetric analysis (TGA) results which were presented in the 45 Day report (Part 2 of this document). The raw data for all analyses, with the exception of DSC and TGA, are also included in this report.
Measurements of the global distribution of carbon monoxide in the troposphere
NASA Technical Reports Server (NTRS)
Hinton, R. R.
1982-01-01
Carbon monoxide and methane grab samples were obtained simultaneously with ozone, aerosol, nitric oxide and DACOM CO measurements. Eighty grab samples were collected at various altitudes up to 19,000 ft. along a north-south flight path from Wallops Flight Center, VA to 11 N. CO and CH were analyzed by flame ionization gas chromatography with cryogenic preconcentration. The relationship between CO and O3 concentrated is examined. A comparative analysis between trends in aerosol and CO concentration is performed.
Apollo Saturn 511 effluent measurements from the Apollo 16 launch operations: An experiment
NASA Technical Reports Server (NTRS)
Gregory, G. L.; Hulten, W. C.; Wornom, D. E.
1974-01-01
An experiment was performed in conjunction with the Apollo 16 launch to define operational and instrumentational problems associated with launch-vehicle exhaust effluent monitoring. Ground and airborne sampling were performed for CO, CO2, hydrocarbons, and particulates. Sampling systems included filter pads and photometers for particulates and whole-air grab samples for gases. Launch debris was identified in the particulate samples at ground level(taken immediately after launch) and in the airborne measurements (taken 40 to 50 minutes after launch approximately 40 km downwind of the pad). Operational problems were identified and included the need for higher instrumentation mobility and the need for real-time sampling instrumentation as opposed to collection-type samples such as the whole-air grab sample.
Praying Mantis Bending Core Breakoff and Retention Mechanism
NASA Technical Reports Server (NTRS)
Badescu, Mircea; Sherrit, Stewart; Bar-Cohen, Yoseph; Bao, Xiaoqi; Lindermann, Randel A.
2011-01-01
Sampling cores requires the controlled breakoff of the core at a known location with respect to the drill end. An additional problem is designing a mechanism that can be implemented at a small scale, yet is robust and versatile enough to be used for a variety of core samples. The new design consists of a set of tubes (a drill tube, an outer tube, and an inner tube) and means of sliding the inner and outer tubes axially relative to each other. Additionally, a sample tube can be housed inside the inner tube for storing the sample. The inner tube fits inside the outer tube, which fits inside the drill tube. The inner and outer tubes can move axially relative to each other. The inner tube presents two lamellae with two opposing grabbing teeth and one pushing tooth. The pushing tooth is offset axially from the grabbing teeth. The teeth can move radially and their motion is controlled by the outer tube. The outer tube presents two lamellae with radial extrusions to control the inner tube lamellae motion. In breaking the core, the mechanism creates two support points (the grabbing teeth and the bit tip) and one push point. The core is broken in bending. The grabbing teeth can also act as a core retention mechanism. The praying mantis that is disclosed herein is an active core breaking/retention mechanism that requires only one additional actuator other than the drilling actuator. It can break cores that are attached to the borehole bottom as
Beyond ADA Accessibility Requirements: Meeting Seniors' Needs for Toilet Transfers.
Lee, Su Jin; Sanford, Jon; Calkins, Margaret; Melgen, Sarah; Endicott, Sarah; Phillips, Anjanette
2018-04-01
To identify the optimal spatial and dimensional requirements of grab bars that support independent and assisted transfers by older adults and their care providers. Although research has demonstrated that toilet grab bars based on the Americans with Disabilities Act (ADA) Accessibility Standards do not meet the needs of older adults, the specific dimensional requirements for alternative configurations are unknown. A two-phased study with older adults and care providers in residential facilities was conducted to determine the optimal requirements for grab bars. Seniors and caregivers in skilled nursing facilities performed transfers using a mock-up toilet. In Phase 1, participants evaluated three grab bar configurations to identify optimal characteristics for safety, ease of use, comfort, and helpfulness. These characteristics were then validated for using ability-matched samples in Phase 2. The optimal configuration derived in Phase 1 included fold-down grab bars on both sides of the toilet (14" from centerline [CL] of toilet, 32" above the floor, and extended a minimum of 6" in front of the toilet) with one side open and a sidewall 24" from CL of toilet on the other. Phase 2 feedback was significantly positive for independent and one-person transfers and somewhat lower, albeit still positive, for two-person transfers. The study provides substantial evidence that bilateral grab bars are significantly more effective than those that comply with current ADA Accessibility Standards. Findings provide specific spatial and dimensional attributes for grab bar configurations that would be most effective in senior facilities.
Engelbrecht, Johann P; McDonald, Eric V; Gillies, John A; Jayanty, R K M Jay; Casuccio, Gary; Gertler, Alan W
2009-02-01
The purpose of the Enhanced Particulate Matter Surveillance Program was to provide scientifically founded information on the chemical and physical properties of dust collected during a period of approximately 1 year in Djibouti, Afghanistan (Bagram, Khowst), Qatar, United Arab Emirates, Iraq (Balad, Baghdad, Tallil, Tikrit, Taji, Al Asad), and Kuwait (northern, central, coastal, and southern regions). To fully understand mineral dusts, their chemical and physical properties, as well as mineralogical inter-relationships, were accurately established. In addition to the ambient samples, bulk soil samples were collected at each of the 15 sites. In each case, approximately 1 kg of soil from the top 10 mm at a previously undisturbed area near the aerosol sampling site was collected. The samples were air-dried and sample splits taken for soil analysis. Further sample splits were sieved to separate the < 38 micro m particle fractions for mineralogical analysis. Examples of major-element and trace-element chemistry, mineralogy, and other physical properties of the 15 grab samples are presented. The purpose of the trace-element analysis was to measure levels of potentially harmful metals while the major-element and ion-chemistry analyses provided an estimate of mineral components. X-ray diffractometry provided a measure of the mineral content of the dust. Scanning electron microscopy with energy dispersive spectroscopy was used to analyze chemical composition of small individual particles. From similarities in the chemistry and mineralogy of re-suspended and ambient sample sets, it is evident that portions of the ambient dust are from local soils.
Representativeness of laboratory sampling procedures for the analysis of trace metals in soil.
Dubé, Jean-Sébastien; Boudreault, Jean-Philippe; Bost, Régis; Sona, Mirela; Duhaime, François; Éthier, Yannic
2015-08-01
This study was conducted to assess the representativeness of laboratory sampling protocols for purposes of trace metal analysis in soil. Five laboratory protocols were compared, including conventional grab sampling, to assess the influence of sectorial splitting, sieving, and grinding on measured trace metal concentrations and their variability. It was concluded that grinding was the most important factor in controlling the variability of trace metal concentrations. Grinding increased the reproducibility of sample mass reduction by rotary sectorial splitting by up to two orders of magnitude. Combined with rotary sectorial splitting, grinding increased the reproducibility of trace metal concentrations by almost three orders of magnitude compared to grab sampling. Moreover, results showed that if grinding is used as part of a mass reduction protocol by sectorial splitting, the effect of sieving on reproducibility became insignificant. Gy's sampling theory and practice was also used to analyze the aforementioned sampling protocols. While the theoretical relative variances calculated for each sampling protocol qualitatively agreed with the experimental variances, their quantitative agreement was very poor. It was assumed that the parameters used in the calculation of theoretical sampling variances may not correctly estimate the constitutional heterogeneity of soils or soil-like materials. Finally, the results have highlighted the pitfalls of grab sampling, namely, the fact that it does not exert control over incorrect sampling errors and that it is strongly affected by distribution heterogeneity.
Young, Stacie T.M.; Ball, Marcael T.J.
2004-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data were collected at two sites, continuous streamflow data at three sites, and water-quality data at five sites, which include the three streamflow sites. This report summarizes rainfall, streamflow, and water-quality data collected between July 1, 2003 and June 30, 2004. A total of 30 samples was collected over four storms during July 1, 2003 to June 30, 2004. In general, an attempt was made to collect grab samples nearly simultaneously at all five sites, and flow-weighted time-composite samples were collected at the three sites equipped with automatic samplers. However, all four storms were partially sampled because either not all stations were sampled or only grab samples were collected. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, copper, lead, and zinc). Grab samples were additionally analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/quality-control samples, collected during storms and during routine maintenance, were also collected to verify analytical procedures and check the effectiveness of equipment-cleaning procedures.
Savoie, Jennifer G.; LeBlanc, Denis R.
2012-01-01
Field tests were conducted near the Impact Area at Camp Edwards on the Massachusetts Military Reservation, Cape Cod, Massachusetts, to determine the utility of no-purge groundwater sampling for monitoring concentrations of ordnance-related explosive compounds and perchlorate in the sand and gravel aquifer. The no-purge methods included (1) a diffusion sampler constructed of rigid porous polyethylene, (2) a diffusion sampler constructed of regenerated-cellulose membrane, and (3) a tubular grab sampler (bailer) constructed of polyethylene film. In samples from 36 monitoring wells, concentrations of perchlorate (ClO4-), hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), the major contaminants of concern in the Impact Area, in the no-purge samples were compared to concentrations of these compounds in samples collected by low-flow pumped sampling with dedicated bladder pumps. The monitoring wells are constructed of 2- and 2.5-inch-diameter polyvinyl chloride pipe and have approximately 5- to 10-foot-long slotted screens. The no-purge samplers were left in place for 13-64 days to ensure that ambient groundwater flow had flushed the well screen and concentrations in the screen represented water in the adjacent formation. The sampling methods were compared first in six monitoring wells. Concentrations of ClO4-, RDX, and HMX in water samples collected by the three no-purge sampling methods and low-flow pumped sampling were in close agreement for all six monitoring wells. There is no evidence of a systematic bias in the concentration differences among the methods on the basis of type of sampling device, type of contaminant, or order in which the no-purge samplers were tested. A subsequent examination of vertical variations in concentrations of ClO4- in the 10-foot-long screens of six wells by using rigid porous polyethylene diffusion samplers indicated that concentrations in a given well varied by less than 15 percent and the small variations were unlikely to affect the utility of the various sampling methods. The grab sampler was selected for additional tests in 29 of the 36 monitoring wells used during the study. Concentrations of ClO4-, RDX, HMX, and other minor explosive compounds in water samples collected by using a 1-liter grab sampler and low-flow pumped sampling were in close agreement in field tests in the 29 wells. A statistical analysis based on the sign test indicated that there was no bias in the concentration differences between the methods. There also was no evidence for a systematic bias in concentration differences between the methods related to location of the monitoring wells laterally or vertically in the groundwater-flow system. Field tests in five wells also demonstrated that sample collection by using a 2-liter grab sampler and sequential bailing with the 1-liter grab sampler were options for obtaining sufficient sample volume for replicate and spiked quality assurance and control samples. The evidence from the field tests supports the conclusion that diffusion sampling with the rigid porous polyethylene and regenerated-cellulose membranes and grab sampling with the polyethylene-film samplers provide comparable data on the concentrations of ordnance-related compounds in groundwater at the MMR to that obtained by low-flow pumped sampling. These sampling methods are useful methods for monitoring these compounds at the MMR and in similar hydrogeologic environments.
NASA Astrophysics Data System (ADS)
Jomaa, Seifeddine; Jiang, Sanyuan; Yang, Xiaoqiang; Rode, Michael
2016-04-01
It is known that a good evaluation and prediction of surface water pollution is mainly limited by the monitoring strategy and the capability of the hydrological water quality model to reproduce the internal processes. To this end, a compromise sampling frequency, which can reflect the dynamical behaviour of leached nutrient fluxes responding to changes in land use, agriculture practices and point sources, and appropriate process-based water quality model are required. The objective of this study was to test the identification of hydrological water quality model parameters (nitrogen and phosphorus) under two different monitoring strategies: (1) regular grab-sampling approach and (2) regular grab-sampling with additional monitoring during the hydrological events using automatic samplers. First, the semi-distributed hydrological water quality HYPE (Hydrological Predictions for the Environment) model was successfully calibrated (1994-1998) for discharge (NSE = 0.86), nitrate-N (lowest NSE for nitrate-N load = 0.69), particulate phosphorus and soluble phosphorus in the Selke catchment (463 km2, central Germany) for the period 1994-1998 using regular grab-sampling approach (biweekly to monthly for nitrogen and phosphorus concentrations). Second, the model was successfully validated during the period 1999-2010 for discharge, nitrate-N, particulate-phosphorus and soluble-phosphorus (lowest NSE for soluble phosphorus load = 0.54). Results, showed that when additional sampling during the events with random grab-sampling approach was used (period 2011-2013), the hydrological model could reproduce only the nitrate-N and soluble phosphorus concentrations reasonably well. However, when additional sampling during the hydrological events was considered, the HYPE model could not represent the measured particulate phosphorus. This reflects the importance of suspended sediment during the hydrological events increasing the concentrations of particulate phosphorus. The HYPE model could reproduce the total phosphorus during the period 2011-2013 only when the sediment transport-related model parameters was re-identified again considering the automatic sampling during the high-flow conditions.
NASA Technical Reports Server (NTRS)
Itoh, T.; Kubo, H.; Honda, H.; Tominaga, T.; Makide, Y.; Yakohata, A.; Sakai, H.
1985-01-01
Measurements of concentrations of chlorofluoromethanes (CFMs), carbon dioxide and carbon isotope ratio in stratospheric and tropospheric air by grab-sampling systems are reported. The balloon-borne grab-sampling system has been launched from Sanriku Balloon Center three times since 1981. It consists of: (1) six sampling cylinders, (2) eight motor driven values, (3) control and monitor circuits, and (4) pressurized housing. Particular consideration is paid to the problem of contamination. Strict requirements are placed on the choice of materials and components, construction methods, cleaning techniques, vacuum integrity, and sampling procedures. An aluminum pressurized housing and a 4-m long inlet line are employed to prevent the sampling air from contamination by outgassing of sampling and control devices. The sampling is performed during the descent of the system. Vertical profiles of mixing ratios of CF2Cl2, CFCl3 and CH4 are given. Mixing ratios of CF2Cl2 and CFCl3 in the stratosphere do not show the discernible effect of the increase of those in the ground level background, and decrease with altitude. Decreasing rate of CFCl3 is larger than that of CF2Cl2. CH4 mixing ratio, on the other hand, shows diffusive equilibrium, as the photodissociation cross section of CH4 is small and concentrations of OH radical and 0(sup I D) are low.
Young, Stacie T.M.; Ball, Marcael T.J.
2003-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data was collected at two sites, continuous streamflow data at three sites, and water-quality data at five sites, which include the three streamflow sites. This report summarizes rainfall, streamflow, and water-quality data collected between July 1, 2002 to June 30, 2003. A total of 28 samples were collected over five storms during July 1, 2002 to June 30, 2003. For two of the five storms, five grab samples and three flow-weighted timecomposite samples were collected. Grab samples were collected nearly simultaneously at all five sites, and flow-weighted timecomposite samples were collected at the three sites equipped with automatic samplers. The other three storms were partially sampled, where only flow-weighted time-composite samples were collected and/or not all stations were sampled. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, copper, lead, and zinc). Grab samples were additionally analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/qualitycontrol samples, collected during storms and during routine maintenance, were also collected to verify analytical procedures and insure proper cleaning of equipment.
Fluid sampling system for a nuclear reactor
Lau, Louis K.; Alper, Naum I.
1994-01-01
A system of extracting fluid samples, either liquid or gas, from the interior of a nuclear reactor containment utilizes a jet pump. To extract the sample fluid, a nonradioactive motive fluid is forced through the inlet and discharge ports of a jet pump located outside the containment, creating a suction that draws the sample fluid from the containment through a sample conduit connected to the pump suction port. The mixture of motive fluid and sample fluid is discharged through a return conduit to the interior of the containment. The jet pump and means for removing a portion of the sample fluid from the sample conduit can be located in a shielded sample grab station located next to the containment. A non-nuclear grade active pump can be located outside the grab sampling station and the containment to pump the nonradioactive motive fluid through the jet pump.
Fluid sampling system for a nuclear reactor
Lau, L.K.; Alper, N.I.
1994-11-22
A system of extracting fluid samples, either liquid or gas, from the interior of a nuclear reactor containment utilizes a jet pump. To extract the sample fluid, a nonradioactive motive fluid is forced through the inlet and discharge ports of a jet pump located outside the containment, creating a suction that draws the sample fluid from the containment through a sample conduit connected to the pump suction port. The mixture of motive fluid and sample fluid is discharged through a return conduit to the interior of the containment. The jet pump and means for removing a portion of the sample fluid from the sample conduit can be located in a shielded sample grab station located next to the containment. A non-nuclear grade active pump can be located outside the grab sampling station and the containment to pump the nonradioactive motive fluid through the jet pump. 1 fig.
Chapin, Thomas
2015-01-01
Hand-collected grab samples are the most common water sampling method but using grab sampling to monitor temporally variable aquatic processes such as diel metal cycling or episodic events is rarely feasible or cost-effective. Currently available automated samplers are a proven, widely used technology and typically collect up to 24 samples during a deployment. However, these automated samplers are not well suited for long-term sampling in remote areas or in freezing conditions. There is a critical need for low-cost, long-duration, high-frequency water sampling technology to improve our understanding of the geochemical response to temporally variable processes. This review article will examine recent developments in automated water sampler technology and utilize selected field data from acid mine drainage studies to illustrate the utility of high-frequency, long-duration water sampling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
George, A.C.; Knutson, E.O.; Tu, K.W.
1995-12-01
The results from the May 1995 Intercomparison of Active, Passive and Continuous Instruments for Radon and Radon Progeny Measurement conducted in the EML radon exposure and test facility are presented. Represented were 13 participants that measure radon with open faced and diffusion barrier activated carbon collectors, 10 with nuclear alpha track detectors, 9 with short-term and long-term electret/ionization chambers, and 13 with active and passive commercial electronic continuous monitors. For radon progeny, there were four participants that came in person to take part in the grab sampling methodology for measuring individual radon progeny and the potential alpha energy concentration (PAEC).more » There were 11 participants with continuous and integrating commercial electronic instruments that are used for measuring the PAEC. The results indicate that all the tested instruments that measure radon fulfill their intended purpose. All instruments and methods used for grab sampling for radon progeny did very well. However, most of the continuous and integrating electronic instruments used for measuring the PAEC or working level appear to underestimate the potential risk from radon progeny when the concentration of particles onto which the radon progeny are attached is <5,000 cm{sup -3}.« less
NASA Astrophysics Data System (ADS)
Van Hoey, Gert; Birchenough, Silvana N. R.; Hostens, Kris
2014-02-01
Biological value estimation is based on a set of assessment questions and several thresholds to delineate areas of ecological importance (e.g. biodiversity). An existing framework, that was specifically designed to assess the ecosystem biodiversity, was expanded by adding new questions on the productivity, functionality and biogeochemical status of benthic habitats. The additional ecological and sedimentological information was collected by using sediment profile imagery (SPI) and grab sampling. Additionally, information on the performance and comparability of both techniques is provided in this study. The research idea was tested at a site near the harbor of Zeebrugge, an area under consideration as a new disposal site for dredged material from the harbor entrance. The sedimentology of the area can be adequately described based on the information from both SPI and Van Veen grab samples, but only the SPI revealed structural information on the physical habitat (layering, a-RPD). The latter information represented the current status of the benthic habitat, which was confirmed by the Van Veen grab samples. All information was summarized through the biological valuation framework, and provided clear evidence of the differences in biological value for the different sediment types within the area. We concluded that the installation of a new dredged material disposal site in this area was not in conflict with the benthic ecology. This area has a low biological value and the benthic system is adapted to changing conditions, which was signaled by the dominance of mobile, short living and opportunistic species. This study showed that suitable sedimentological and ecological information can be gathered by these traditional and complementary techniques, to estimate the biological value of an area in the light of marine spatial planning and environmental impact assessments.
Taxonomic Evaluation of Cleveland Harbor Lake Areas
2014-01-01
collected using a standard (8.2-L) stainless steel ponar grab (229 x 229 mm) in basic accordance with USEPA (2001). The grab sampler was dropped from...through stacked 1.0- and 0.5-mm stainless steel sieves to separate coarse and fine material. Sample material retained in both sieves was thoroughly... 416 . Berry, E. 1943. The Amnicolidae of Michigan: Distribution, ecology, and taxonomy. Misc. Publ. Mus. Zool. U. Mich. 57:1-68. Dillon, R. T., Jr
Borak, T B
1986-04-01
Periodic grab sampling in combination with time-of-occupancy surveys has been the accepted procedure for estimating the annual exposure of underground U miners to Rn daughters. Temporal variations in the concentration of potential alpha energy in the mine generate uncertainties in this process. A system to randomize the selection of locations for measurement is described which can reduce uncertainties and eliminate systematic biases in the data. In general, a sample frequency of 50 measurements per year is sufficient to satisfy the criteria that the annual exposure be determined in working level months to within +/- 50% of the true value with a 95% level of confidence. Suggestions for implementing this randomization scheme are presented.
Barnard, P.L.; Rubin, D.M.; Harney, J.; Mustain, N.
2007-01-01
This extensive field test of an autocorrelation technique for determining grain size from digital images was conducted using a digital bed-sediment camera, or 'beachball' camera. Using 205 sediment samples and >1200 images from a variety of beaches on the west coast of the US, grain size ranging from sand to granules was measured from field samples using both the autocorrelation technique developed by Rubin [Rubin, D.M., 2004. A simple autocorrelation algorithm for determining grain size from digital images of sediment. Journal of Sedimentary Research, 74(1): 160-165.] and traditional methods (i.e. settling tube analysis, sieving, and point counts). To test the accuracy of the digital-image grain size algorithm, we compared results with manual point counts of an extensive image data set in the Santa Barbara littoral cell. Grain sizes calculated using the autocorrelation algorithm were highly correlated with the point counts of the same images (r2 = 0.93; n = 79) and had an error of only 1%. Comparisons of calculated grain sizes and grain sizes measured from grab samples demonstrated that the autocorrelation technique works well on high-energy dissipative beaches with well-sorted sediment such as in the Pacific Northwest (r2 ??? 0.92; n = 115). On less dissipative, more poorly sorted beaches such as Ocean Beach in San Francisco, results were not as good (r2 ??? 0.70; n = 67; within 3% accuracy). Because the algorithm works well compared with point counts of the same image, the poorer correlation with grab samples must be a result of actual spatial and vertical variability of sediment in the field; closer agreement between grain size in the images and grain size of grab samples can be achieved by increasing the sampling volume of the images (taking more images, distributed over a volume comparable to that of a grab sample). In all field tests the autocorrelation method was able to predict the mean and median grain size with ???96% accuracy, which is more than adequate for the majority of sedimentological applications, especially considering that the autocorrelation technique is estimated to be at least 100 times faster than traditional methods.
NASA Technical Reports Server (NTRS)
1994-01-01
The ChemScan UV-6100 is a spectrometry system originally developed by Biotronics Technologies, Inc. under a Small Business Innovation Research (SBIR) contract. It is marketed to the water and wastewater treatment industries, replacing "grab sampling" with on-line data collection. It analyzes the light absorbance characteristics of a water sample, simultaneously detects hundreds of individual wavelengths absorbed by chemical substances in a process solution, and quantifies the information. Spectral data is then processed by ChemScan analyzer and compared with calibration files in the system's memory in order to calculate concentrations of chemical substances that cause UV light absorbance in specific patterns. Monitored substances can be analyzed for quality and quantity. Applications include detection of a variety of substances, and the information provided enables an operator to control a process more efficiently.
Branchet, Perrine; Cadot, Emmanuelle; Fenet, Hélène; Sebag, David; Ngatcha, Benjamin Ngounou; Borrell-Estupina, Valérie; Ngoupayou, Jules Remy Ndam; Kengne, Ives; Braun, Jean-Jacques; Gonzalez, Catherine
2018-04-18
Urban agriculture is crucial to local populations, but the risk of it contaminating water has rarely been documented. The aim of this study was to assess pesticide contamination of surface waters from the Méfou watershed (Yaoundé, Cameroon) by 32 selected herbicides, fungicides, and insecticides (mainly polar) according to their local application, using both grab sampling and polar organic compounds integrative samplers (POCIS). Three sampling campaigns were conducted in the March/April and October/November 2015 and June/July 2016 rainy seasons in urban and peri-urban areas. The majority of the targeted compounds were detected. The quantification frequencies of eight pesticides were more than 20% with both POCIS and grab sampling, and that of diuron and atrazine reached 100%. Spatial differences in contamination were evidenced with higher contamination in urban than peri-urban rivers. In particular, diuron was identified as an urban contaminant of concern because its concentrations frequently exceeded the European water quality guideline of 0.200 μg/L in freshwater and may thus represent an ecological risk due to a risk quotient > 1 for algae observed in 94% of grab samples. This study raises concerns about the impacts of urban agriculture on the quality of water resources and to a larger extent on the health of the inhabitants of cities in developing countries. Graphical abstract ᅟ.
Hassoun, P; Viudes, G; Autran, P; Bastianelli, D; Bocquier, F
2013-08-01
In experiments based on ruminants' individual dry matter intake (DMI) assessment, several external markers can be used to estimate faecal output when total faeces collection is not possible. However, preparation of the markers to be administered and analytical procedures used for marker content determination are time-consuming thus strongly limiting the number of animals involved in the experiments. In this paper, polyethylene glycol (PEG, molecular weight 6000 da) was tested as a faecal marker. Four trials were conducted on dry, non-lactating ewes kept in digestibility crates that allowed individual measurements. The overall experiment was designed to assess the major factors that could lessen the effectiveness of this method, assuming that the use of grab samples of faeces is sufficient. Trial 1 was designed to test two levels of PEG (20 and 40 g/day) administered in two equal amounts. Trial 2 was designed to test the effect of either a single morning (0800 h) dose (20 g/day) or a twice daily administration (0800 and 1600 h) of the same fractionated dose. Trial 3 was designed to test a 20 g/day dose of PEG administered once daily to ewes fed with hays of different qualities: medium (MH) and low (LH). In trial 4, a lower dose of PEG (10 g/day) was administered once a day to ewes fed with fresh oat-vetch forage. It was demonstrated that PEG could be precisely estimated (average prediction error = 3.47 g/kg) with near-infrared reflectance spectroscopy (NIRS). On the basis of the four trials, it has been proved that PEG administration (20 and 40 g/day) did not significantly affect the DMI of ewes fed dry diets (trials 1, 2 and 3), whereas there was an unexpected increase of DMI for ewes fed exclusively with green feed (trial 4) without DM digestibility modification. Providing PEG as a single dose (0800 h) or split into two equal parts (0800 and 1600 h) did not alter the estimated DMI. Considering the interest of grab sampling, there were clear variations of PEG in faeces with higher concentrations observed at 0800 and 1600 h and lower concentrations at 1400 h. Consequently, with PEG (measured with NIRS) administered once and using the grab sampling procedure (morning collection), it is possible to estimate the DMI of dry feeds with good accuracy. For green feeds, more research is needed as the estimated results are still highly variable.
Neonicotinoid pesticides in drinking water in agricultural regions of southern Ontario, Canada.
Sultana, Tamanna; Murray, Craig; Kleywegt, Sonya; Metcalfe, Chris D
2018-07-01
Because of the persistence and solubility of neonicotinoid insecticides (NNIs), there is concern that these compounds may contaminate sources of drinking water. The objective of this project was to evaluate the distribution of NNIs in raw and treated drinking water from selected municipalities that draw their water from the lower Great Lakes in areas of southern Ontario, Canada where there is high intensity agriculture. Sites were monitored using Polar Organic Chemical Integrative Samplers (POCIS) and by collecting grab samples at six drinking water treatment plants. Thiamethoxam, clothianidin and imidacloprid were detected in both POCIS and grab samples of raw water. The frequency of detection of NNIs was much lower in treated drinking water, but some compounds were still detected at estimated concentrations in the low ng L -1 range. Thiamethoxam was detected in one grab sample of raw drinking water at a mean concentration of 0.28 μg L -1 , which is above the guidelines for drinking water recommended in some jurisdictions, including the European Union directive on pesticide levels <0.1 μg L -1 in water intended for human consumption. Further work is required to determine whether contamination of sources of drinking water with this class of insecticides is a global problem in agricultural regions. Copyright © 2018 Elsevier Ltd. All rights reserved.
Day and night profiles of tropospheric nitrous oxide
NASA Technical Reports Server (NTRS)
Cofer, Wesley R., III; Connors, Vickie S.; Levine, Joel S.; Edahl, Robert A., Jr.
1986-01-01
Daytime and nighttime vertical profiles of the tropospheric trace gas N2O were determined from grab sample collections off the Atlantic and Gulf coasts of Florida. The grab samples were collected during the week of October 7-13, 1984, from a Lear jet during descent spirals over an altitude range of 12.5-0.3 km in approximately 1.2-km intervals. During this period there were two distinct airflow regimes sampled: (1) the surface boundary layer (less than 2 km), in which the wind direction was typically easterly; and (2) the regime above the boundary layer, which was predominantly characterized by westerly flow. N2O mixing ratios, normalized to dry air, were determined from 148 daytime and nighttime samplings. N2O was found to be uniformly mixed at all altitudes at 301.9 + or - 2.4 parts per billion by volume.
Investigation of Tank 241-AW-104 Composite Floating Layer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meznarich, H. K.; Bolling, S. D.; Lachut, J. S.
Seven grab samples and one field blank were taken from Tank 241-AW-104 (AW-104) on June 2, 2017, and received at 222-S Laboratory on June 5, 2017. A visible layer with brown solids was observed floating on the top of two surface tank waste samples (4AW-17-02 and 4AW 17 02DUP). The floating layer from both samples was collected, composited, and submitted for chemical analyses and solid phase characterization in order to understand the composition of the floating layer. Tributyl phosphate and tridecane were higher in the floating layer than in the aqueous phase. Density in the floating layer was slightly lowermore » than the mean density of all grab samples. Sodium nitrate and sodium carbonate were major components with a trace of gibbsite and very small size agglomerates were present in the solids of the floating layer. The supernate consisted of organics, soluble salt, and particulates.« less
Shi, Zhenhao; Wang, An-Li; Aronowitz, Catherine A; Romer, Daniel; Langleben, Daniel D
2017-09-01
Studies testing the benefits of enriching smoking-cessation video ads with attention-grabbing sensory features have yielded variable results. Dopamine transporter gene (DAT1) has been implicated in attention deficits. We hypothesized that DAT1 polymorphism is partially responsible for this variability. Using functional magnetic resonance imaging, we examined brain responses to videos high or low in attention-grabbing features, indexed by "message sensation value" (MSV), in 53 smokers genotyped for DAT1. Compared to other smokers, 10/10 homozygotes showed greater neural response to High- vs. Low-MSV smoking-cessation videos in two a priori regions of interest: the right temporoparietal junction and the right ventrolateral prefrontal cortex. These regions are known to underlie stimulus-driven attentional processing. Exploratory analysis showed that the right temporoparietal response positively predicted follow-up smoking behavior indexed by urine cotinine. Our findings suggest that responses to attention-grabbing features in smoking-cessation messages is affected by the DAT1 genotype. Copyright © 2017. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Audet, J.; Martinsen, L.; Hasler, B.; de Jonge, H.; Karydi, E.; Ovesen, N. B.; Kronvang, B.
2014-07-01
Eutrophication of aquatic ecosystems caused by excess concentrations of nitrogen and phosphorus may have harmful consequences for biodiversity and poses a health risk to humans via the water supplies. Reduction of nitrogen and phosphorus losses to aquatic ecosystems involves implementation of costly measures, and reliable monitoring methods are therefore essential to select appropriate mitigation strategies and to evaluate their effects. Here, we compare the performances and costs of three methodologies for the monitoring of nutrients in rivers: grab sampling, time-proportional sampling and passive sampling using flow proportional samplers. Assuming time-proportional sampling to be the best estimate of the "true" nutrient load, our results showed that the risk of obtaining wrong total nutrient load estimates by passive samplers is high despite similar costs as the time-proportional sampling. Our conclusion is that for passive samplers to provide a reliable monitoring alternative, further development is needed. Grab sampling was the cheapest of the three methods and was more precise and accurate than passive sampling. We conclude that although monitoring employing time-proportional sampling is costly, its reliability precludes unnecessarily high implementation expenses.
NASA Astrophysics Data System (ADS)
Audet, J.; Martinsen, L.; Hasler, B.; de Jonge, H.; Karydi, E.; Ovesen, N. B.; Kronvang, B.
2014-11-01
Eutrophication of aquatic ecosystems caused by excess concentrations of nitrogen and phosphorus may have harmful consequences for biodiversity and poses a health risk to humans via water supplies. Reduction of nitrogen and phosphorus losses to aquatic ecosystems involves implementation of costly measures, and reliable monitoring methods are therefore essential to select appropriate mitigation strategies and to evaluate their effects. Here, we compare the performances and costs of three methodologies for the monitoring of nutrients in rivers: grab sampling; time-proportional sampling; and passive sampling using flow-proportional samplers. Assuming hourly time-proportional sampling to be the best estimate of the "true" nutrient load, our results showed that the risk of obtaining wrong total nutrient load estimates by passive samplers is high despite similar costs as the time-proportional sampling. Our conclusion is that for passive samplers to provide a reliable monitoring alternative, further development is needed. Grab sampling was the cheapest of the three methods and was more precise and accurate than passive sampling. We conclude that although monitoring employing time-proportional sampling is costly, its reliability precludes unnecessarily high implementation expenses.
Lee, Su Jin; Mehta-Desai, Ricky; Oh, Kyunggeune; Sanford, Jon; Prilutsky, Boris I
2018-03-09
Kinetic characteristics of transfers to and from a toilet performed using bilateral grab bars are not fully quantified to inform grab bar design and configuration. The purpose of this study was to (1) determine effects of bilateral swing-away grab bars on peaks of ankle, knee and hip joint moments during grab bar assisted stand-to-sit and sit-to-stand transfers; and (2) determine effects of three different heights and widths of swing-away grab bars on the same kinetic characteristics. Healthy subjects (N = 11, age 25-58 years) performed stand-to-sit and sit-to-stand transfers with and without grab bars. In transfers with grab bars, 9 grab bar configurations were tested by varying their height from the floor (0.787 m, 0.813 m, 0.838 m; 31″-33″) and width, the distance of each grab bar from the toilet's centerline (0.330 m, 0.356 m, 0.381 m; 13″-15″). Motion capture, force plate and inverse dynamics analysis were used to determine lower limb joint moments. The use of bilateral grab bars generally reduced the peak magnitude of extension moments at lower limb joints during stand-to-sit and sit-to-stand transfers (p < .05), except the ankle joint moments during stand-to-sit transfers. Relatively few differences in peak joint moments were found between studied grab bar widths or heights. The obtained results suggest that the studied ranges of grab bar configurations reduce moment demands on the leg joints and thus decrease difficulty and required lower limb muscle effort to perform the transfers. Implications for Rehabilitation Maximizing the benefits of assistive technology in the built environment requires a careful assessment of their spatial and configurational dimensions, especially in respect to the needs and abilities of the intended users. Examining the kinetic characteristics of transfers to and from a toilet using the swing-away grab bars is useful for informing grab bar design and configuration recommendations for assisted living and skilled nursing facilities. Our findings suggest that the swing-away grab bars located at certain ranges are a reasonable alternative to the grab bars mandated by the current Americans with Disabilities Act (ADA) Accessibility Guidelines. Future research investigating the effects of grab bars on transfer performance should consider additional factors, such as a wider range of abilities and transfer methods of the users.
Compatibility Grab Sampling and Analysis Plan for FY 2000
DOE Office of Scientific and Technical Information (OSTI.GOV)
SASAKI, L.M.
1999-12-29
This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for grab samples obtained to address waste compatibility. It is written in accordance with requirements identified in Data Quality Objectives for Tank Farms Waste Compatibility Program (Mulkey et al. 1999) and Tank Farm Waste Transfer Compatibility Program (Fowler 1999). In addition to analyses to support Compatibility, the Waste Feed Delivery program has requested that tank samples obtained for Compatibility also be analyzed to confirm the high-level waste and/or low-activity waste envelope(s) for the tank waste (Baldwin 1999). The analytical requirements tomore » confirm waste envelopes are identified in Data Quality Objectives for TWRS Privatization Phase I: Confirm Tank T is an Appropriate Feed Source for Low-Activity Waste Feed Batch X (Nguyen 1999a) and Data Quality Objectives for RPP Privatization Phase I: Confirm Tank T is an Appropriate Feed Source for High-Level Waste Feed Batch X (Nguyen 1999b).« less
40 CFR 63.997 - Performance test and compliance assessment requirements for control devices.
Code of Federal Regulations, 2012 CFR
2012-07-01
... regulated materials are loaded, and samples shall be collected using integrated sampling or grab samples... material concentration and percent reduction may be measured as either total organic regulated material or... regulated material or TOC, sampling sites shall be located as specified in paragraphs (e)(2)(i)(A)(1) and (e...
40 CFR 63.997 - Performance test and compliance assessment requirements for control devices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... regulated materials are loaded, and samples shall be collected using integrated sampling or grab samples... material concentration and percent reduction may be measured as either total organic regulated material or... regulated material or TOC, sampling sites shall be located as specified in paragraphs (e)(2)(i)(A)(1) and (e...
40 CFR 63.997 - Performance test and compliance assessment requirements for control devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... regulated materials are loaded, and samples shall be collected using integrated sampling or grab samples... material concentration and percent reduction may be measured as either total organic regulated material or... regulated material or TOC, sampling sites shall be located as specified in paragraphs (e)(2)(i)(A)(1) and (e...
Soyuz 27 Return Samples: Air Quality Aboard the International Space Station: Revised
NASA Technical Reports Server (NTRS)
James, John T.
2012-01-01
The toxicological assessment of 6 GSCs from the ISS is shown. The average recoveries of the 3 surrogate standards from the grab sample containers were as follows: C-13-acetone, 115%; fluorobenzene, 108%; and chlorobenzene, 93%.
Modeling and validating the grabbing forces of hydraulic log grapples used in forest operations
Jingxin Wang; Chris B. LeDoux; Lihai Wang
2003-01-01
The grabbing forces of log grapples were modeled and analyzed mathematically under operating conditions when grabbing logs from compact log piles and from bunch-like log piles. The grabbing forces are closely related to the structural parameters of the grapple, the weight of the grapple, and the weight of the log grabbed. An operational model grapple was designed and...
A MORE COST-EFFECTIVE EMAP-ESTUARIES BENTHIC MACROFAUNAL SAMPLING PROTOCOL
The standard benthic macrofaunal sampling protocol in the U.S. Environmental Protection Agency's Pacific Coast Environmental Monitoring and Assessment Program (EMAP) is to collect a minimum of 30 random benthic samples per reporting unit (e.g., estuary) using a 0.1 m2 grab and to...
Dougherty, Jennifer A.; Swarzenski, Peter W.; Dinicola, Richard S.; Reinhard, Martin
2010-01-01
Organic contaminants, such as pharmaceuticals and personal care products (PPCPs), pose a risk to water quality and the health of ecosystems. This study was designed to determine if a coastal community lacking point sources, such as waste water treatment plant effluent, could release PPCPs, herbicides, and plasticizers at detectable levels to their surface water and groundwater. Research was conducted in Liberty Bay, an embayment within Puget Sound, where 70% of the population (∼10,000) uses septic systems. Sampling included collection of groundwater and surface water with grab samples and the use of polar organic chemical integrative samplers (POCIS). We analyzed for a broad spectrum of 25 commonly used compounds, including PPCPs, herbicides, and a flame retardant. Twelve contaminants were detected at least once; only N,N-diethyl-meta-toluamide, caffeine, and mecoprop, a herbicide not attributed to septic systems, were detected in more than one grab sample. The use of POCIS was essential because contaminants were present at very low levels (nanograms), which is common for PPCPs in general, but particularly so in such a small community. The use of POCIS allowed the detection of five compounds that were not present in grab samples. Data suggest that the community is contaminating local water with PPCPs; this effect is likely to increase as the population and product usage increase. The results presented here are a first step toward assessing the transport of herbicides and PPCPs into this coastal system.
Dougherty, Jennifer A; Swarzenski, Peter W; Dinicola, Richard S; Reinhard, Martin
2010-01-01
Organic contaminants, such as pharmaceuticals and personal care products (PPCPs), pose a risk to water quality and the health of ecosystems. This study was designed to determine if a coastal community lacking point sources, such as waste water treatment plant effluent, could release PPCPs, herbicides, and plasticizers at detectable levels to their surface water and groundwater. Research was conducted in Liberty Bay, an embayment within Puget Sound, where 70% of the population (-10,000) uses septic systems. Sampling included collection of groundwater and surface water with grab samples and the use of polar organic chemical integrative samplers (POCIS). We analyzed for a broad spectrum of 25 commonly used compounds, including PPCPs, herbicides, and a flame retardant. Twelve contaminants were detected at least once; only N,N-diethyl-meta-toluamide, caffeine, and mecoprop, a herbicide not attributed to septic systems, were detected in more than one grab sample. The use of POCIS was essential because contaminants were present at very low levels (nanograms), which is common for PPCPs in general, but particularly so in such a small community. The use of POCIS allowed the detection of five compounds that were not present in grab samples. Data suggest that the community is contaminating local water with PPCPs; this effect is likely to increase as the population and product usage increase. The results presented here are a first step toward assessing the transport of herbicides and PPCPs into this coastal system.
NASA Technical Reports Server (NTRS)
James, John T.
2007-01-01
The toxicological assessments of 2 grab sample canisters (GSCs) from the Shuttle are reported. Analytical methods have not changed from earlier reports. The Shuttle atmosphere was acceptable for human respiration.
Modeled de facto reuse and contaminants of emerging concern in drinking water source waters
Nguyen, Thuy; Westerhoff, Paul; Furlong, Edward T.; Kolpin, Dana W.; Batt, Angela L.; Mash, Heath E.; Schenck, Kathleen M.; Boone, J. Scott; Rice, Jacelyn; Glassmeyer, Susan T.
2018-01-01
De facto reuse is the percentage of drinking water treatment plant (DWTP) intake potentially composed of effluent discharged from upstream wastewater treatment plants (WWTPs). Results from grab samples and a De Facto Reuse in our Nation's Consumable Supply (DRINCS) geospatial watershed model were used to quantify contaminants of emerging concern (CECs) concentrations at DWTP intakes to qualitatively compare exposure risks obtained by the two approaches. Between nine and 71 CECs were detected in grab samples. The number of upstream WWTP discharges ranged from 0 to >1,000; comparative de facto reuse results from DRINCS ranged from <0.1 to 13% during average flow and >80% during lower streamflows. Correlation between chemicals detected and DRINCS modeling results were observed, particularly DWTPs withdrawing from midsize water bodies. This comparison advances the utility of DRINCS to identify locations of DWTPs for future CEC sampling and treatment technology testing.
Investigation of Tank 241-AN-101 Floating Solids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kraft, Douglas P.; Meznarich, H. K.
Tank 241-AN-101 is the receiver tank for retrieval of several C-Farms waste tanks, including Tanks 241-C-102 and 241-C-111. Tank 241 C 111 received first-cycle decontamination waste from the bismuth phosphate process and Plutonium and Uranium Extraction cladding waste, as well as hydraulic fluid. Three grab samples, 1AN-16-01, 1AN-16-01A, and 1AN-16-01B, were collected at the surface of Tank 241-AN-101 on April 25, 2016, after Tank 241-C-111 retrieval was completed. Floating solids were observed in the three grab samples in the 11A hot cell after the samples were received at the 222-S Laboratory. Routine chemical analyses, solid phase characterization on the floatingmore » and settled solids, semivolatile organic analysis mainly on the aqueous phase for identification of degradation products of hydraulic fluids were performed. Investigation of the floating solids is reported.« less
Wolff, Reuben H.; Wong, Michael F.
2008-01-01
Since November 1998, water-quality data have been collected from the H-3 Highway Storm Drain C, which collects runoff from a 4-mi-long viaduct, and from Halawa Stream on Oahu, Hawaii. From January 2001 to August 2004, data were collected from the storm drain and four stream sites in the Halawa Stream drainage basin as part of the State of Hawaii Department of Transportation Storm Water Monitoring Program. Data from the stormwater monitoring program have been published in annual reports. This report uses these water-quality data to explore how the highway storm-drain runoff affects Halawa Stream and the factors that might be controlling the water quality in the drainage basin. In general, concentrations of nutrients, total dissolved solids, and total suspended solids were lower in highway runoff from Storm Drain C than at stream sites upstream and downstream of Storm Drain C. The opposite trend was observed for most trace metals, which generally occurred in higher concentrations in the highway runoff from Storm Drain C than in the samples collected from Halawa Stream. The absolute contribution from Storm Drain C highway runoff, in terms of total storm loads, was much smaller than at stations upstream and downstream, whereas the constituent yields (the relative contribution per unit drainage basin area) at Storm Drain C were comparable to or higher than storm yields at stations upstream and downstream. Most constituent concentrations and loads in stormwater runoff increased in a downstream direction. The timing of the storm sampling is an important factor controlling constituent concentrations observed in stormwater runoff samples. Automated point samplers were used to collect grab samples during the period of increasing discharge of the storm throughout the stormflow peak and during the period of decreasing discharge of the storm, whereas manually collected grab samples were generally collected during the later stages near the end of the storm. Grab samples were analyzed to determine concentrations and loads at a particular point in time. Flow-weighted time composite samples from the automated point samplers were analyzed to determine mean constituent concentrations or loads during a storm. Chemical analysis of individual grab samples from the automated point sampler at Storm Drain C demonstrated the ?first flush? phenomenon?higher constituent concentrations at the beginning of runoff events?for the trace metals cadmium, lead, zinc, and copper, whose concentrations were initially high during the period of increasing discharge and gradually decreased over the duration of the storm. Water-quality data from Storm Drain C and four stream sites were compared to the State of Hawaii Department of Health (HDOH) water-quality standards to determine the effects of highway storm runoff on the water quality of Halawa Stream. The geometric-mean standards and the 10- and 2-percent-of-the-time concentration standards for total nitrogen, nitrite plus nitrate, total phosphorus, total suspended solids, and turbidity were exceeded in many of the comparisons. However, these standards were not designed for stormwater sampling, in which constituent concentrations would be expected to increase for short periods of time. With the aim of enhancing the usefulness of the water-quality data, several modifications to the stormwater monitoring program are suggested. These suggestions include (1) the periodic analyzing of discrete samples from the automated point samplers over the course of a storm to get a clearer profile of the storm, from first flush to the end of the receding discharge; (2) adding an analysis of the dissolved fractions of metals to the sampling plan; (3) installation of an automatic sampler at Bridge 8 to enable sampling earlier in the storms; (4) a one-time sampling and analysis of soils upstream of Bridge 8 for base-line contaminant concentrations; (5) collection of samples from Halawa Stream during low-flow conditions
NASA Astrophysics Data System (ADS)
Kenchington, Ellen L. R.; Gilkinson, Kent D.; MacIsaac, Kevin G.; Bourbonnais-Boyce, Cynthia; Kenchington, Trevor J.; Smith, Stephen J.; Gordon, Donald C., Jr.
2006-10-01
The effects of otter trawling on a hard-bottom ecosystem on Western Bank on Canada's Scotian Shelf were examined experimentally from 1997 to 1999 with an asymmetrical BACI design. The site was located within an area that had been closed to fishing since 1987 to protect juvenile haddock. An experimental line was trawled 12-14 times on three separate occasions over a 20 month period. The benthic macrofauna and megafauna were sampled before and after trawling on both impact and control lines with both a grab and a photographic system. The 100 grab samples collected contained 341 taxa, primarily polychaetes, amphipods and molluscs, the majority (60%) of which were epifaunal. Biomass was dominated by the horse-mussel Modiolus modiolus, a long-lived bivalve, while the tube-building amphipod Ericthonius fasciatus was the most abundant species. Through the study period the benthos on the control lines showed little qualitative or quantitative change in individual taxa or community metrics. However, the abundance of 24 individual taxa (polychaetes, amphipods, echinoderms and molluscs) changed significantly, with the majority of these increasing. This resulted in a significantly different relative abundance of taxa between years as detected through ANOSIM. A significant change in relative biomass amongst the taxa was also observed. Trawling had few detectable immediate effects on the abundance or biomass of individual taxa and none on community composition. A few taxa, primarily a mixture of polychaetes and amphipods, decreased significantly after trawling and data from fish stomachs collected during the experiment (Kenchington, E.L., Gordon Jr., D.C., Bourbonnais-Boyce, C., MacIsaac, K.G., Gilkinson, K.D., McKeown, D.L., Vass, W.P., 2005. Effects of experimental otter trawling on the feeding of demersal fish on Western Bank, Nova Scotia. Amer. Fish. Soc. Symp. 41, 391-409) showed that some of these were scavenged by demersal fish. Fifteen taxa showed significant decreases after trawling when the cumulative effects of trawling were considered. As in the analyses of individual years the species affected were primarily high turn-over species such as polychaetes and amphipods. Dominance curves prepared for both control and impact samples before trawling in 1997 and after trawling in 1999 showed a marked decrease in the biomass values of the highest ranking taxa, particularly of the first species, M. modiolus, only on the impact line at the conclusion of the experiment. The proportion of epifaunal biomass also declined significantly from 90% to 77% on the impact line by the conclusion of the experiment. These changes are in part due to trawl-induced damage and subsequent predation by demersal fish of the top ranking species. Analysis of the photographic images showed that the three top-ranking species in terms of biomass, M. modiolus, the tube-building polychaete Thelepus cincinnatus, and the brachiopod Terebratulina septentrionalis, were visibly damaged more than other species by the trawl gear. Two of these species, M. modiolus and T. cincinnatus, were preyed upon by scavenging demersal fish. The use of multiple sampling devices at the experimental site (grab, photographic system reported here and trawl and fish stomachs reported by Kenchington, E.L., Gordon Jr., D.C., Bourbonnais-Boyce, C., MacIsaac, K.G., Gilkinson, K.D., McKeown, D.L., Vass, W.P., 2005. Effects of experimental otter trawling on the feeding of demersal fish on Western Bank, Nova Scotia. Amer. Fish. Soc. Symp. 41, 391-409) enabled us to link trawl-induced changes to the benthos to predation by demersal fish.
40 CFR 61.107 - Emission determination.
Code of Federal Regulations, 2013 CFR
2013-07-01
... shall be made. For relatively constant flow rates only periodic measurements are necessary. (2... operation. Periodic sampling (grab samples) may be used only with EPA's prior approval. Such approval may be... potential to release radionuclides into the air, periodic confirmatory measurements should be made to verify...
40 CFR 61.107 - Emission determination.
Code of Federal Regulations, 2011 CFR
2011-07-01
... shall be made. For relatively constant flow rates only periodic measurements are necessary. (2... operation. Periodic sampling (grab samples) may be used only with EPA's prior approval. Such approval may be... potential to release radionuclides into the air, periodic confirmatory measurements should be made to verify...
40 CFR 61.107 - Emission determination.
Code of Federal Regulations, 2014 CFR
2014-07-01
... shall be made. For relatively constant flow rates only periodic measurements are necessary. (2... operation. Periodic sampling (grab samples) may be used only with EPA's prior approval. Such approval may be... potential to release radionuclides into the air, periodic confirmatory measurements should be made to verify...
40 CFR 61.107 - Emission determination.
Code of Federal Regulations, 2010 CFR
2010-07-01
... shall be made. For relatively constant flow rates only periodic measurements are necessary. (2... operation. Periodic sampling (grab samples) may be used only with EPA's prior approval. Such approval may be... potential to release radionuclides into the air, periodic confirmatory measurements should be made to verify...
40 CFR 61.107 - Emission determination.
Code of Federal Regulations, 2012 CFR
2012-07-01
... shall be made. For relatively constant flow rates only periodic measurements are necessary. (2... operation. Periodic sampling (grab samples) may be used only with EPA's prior approval. Such approval may be... potential to release radionuclides into the air, periodic confirmatory measurements should be made to verify...
Mapping South San Francisco Bay's seabed diversity for use in wetland restoration planning
Fregoso, Theresa A.; Jaffe, B.; Rathwell, G.; Collins, W.; Rhynas, K.; Tomlin, V.; Sullivan, S.
2006-01-01
Data for an acoustic seabed classification were collected as a part of a California Coastal Conservancy funded bathymetric survey of South Bay in early 2005. A QTC VIEW seabed classification system recorded echoes from a sungle bean 50 kHz echosounder. Approximately 450,000 seabed classification records were generated from an are of of about 30 sq. miles. Ten district acoustic classes were identified through an unsupervised classification system using principle component and cluster analyses. One hundred and sixty-one grab samples and forty-five benthic community composition data samples collected in the study area shortly before and after the seabed classification survey, further refined the ten classes into groups based on grain size. A preliminary map of surficial grain size of South Bay was developed from the combination of the seabed classification and the grab and benthic samples. The initial seabed classification map, the grain size map, and locations of sediment samples will be displayed along with the methods of acousitc seabed classification.
USDA-ARS?s Scientific Manuscript database
Biologically active compounds originating from agricultural, residential, and industrial sources have been detected in surface waters, which have invoked concern of their potential ecological and human health effects. Automated and grab surface water samples, passive water samples - Polar Organic Co...
A MORE COST-EFFECTIVE EMAP-W BENTHIC MACROFAUNAL SAMPLE UNIT
The standard EPA West Coast Environmental Monitoring and Assessment Program (EMAP-W) benthic macrofaunal sampling protocol is to collect 30-50 random benthic samples per reporting unit (e.g., estuary, region) using a 0.1 m2 grab and to sort out macrofauna using a 1.0 mm mesh scre...
Ackerman, Seth D.; Pappal, Adrienne L.; Huntley, Emily C.; Blackwood, Dann S.; Schwab, William C.
2015-01-01
Sea-floor sample collection is an important component of a statewide cooperative mapping effort between the U.S. Geological Survey (USGS) and the Massachusetts Office of Coastal Zone Management (CZM). Sediment grab samples, bottom photographs, and video transects were collected within Vineyard Sound and Buzzards Bay in 2010 aboard the research vesselConnecticut. This report contains sample data and related information, including analyses of surficial-sediment grab samples, locations and images of sea-floor photography, survey lines along which sea-floor video was collected, and a classification of benthic biota observed in sea-floor photographs and based on the Coastal and Marine Ecological Classification Standard (CMECS). These sample data and analyses information are used to verify interpretations of geophysical data and are an essential part of geologic maps of the sea floor. These data also provide a valuable inventory of benthic habitat and resources. Geographic information system (GIS) data, maps, and interpretations, produced through the USGS and CZM mapping cooperative, are intended to aid efforts to manage coastal and marine resources and to provide baseline information for research focused on coastal evolution and environmental change.
40 CFR 61.93 - Emission monitoring and test procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... or frequent flow rate measurements shall be made. For relatively constant flow rates only periodic... applicable to batch processes when the unit is in operation. Periodic sampling (grab samples) may be used... have a potential to release radionuclides into the air, periodic confirmatory measurements shall be...
40 CFR 61.93 - Emission monitoring and test procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... or frequent flow rate measurements shall be made. For relatively constant flow rates only periodic... applicable to batch processes when the unit is in operation. Periodic sampling (grab samples) may be used... have a potential to release radionuclides into the air, periodic confirmatory measurements shall be...
40 CFR 61.93 - Emission monitoring and test procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... or frequent flow rate measurements shall be made. For relatively constant flow rates only periodic... applicable to batch processes when the unit is in operation. Periodic sampling (grab samples) may be used... have a potential to release radionuclides into the air, periodic confirmatory measurements shall be...
40 CFR 61.93 - Emission monitoring and test procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... or frequent flow rate measurements shall be made. For relatively constant flow rates only periodic... applicable to batch processes when the unit is in operation. Periodic sampling (grab samples) may be used... have a potential to release radionuclides into the air, periodic confirmatory measurements shall be...
40 CFR 61.93 - Emission monitoring and test procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... or frequent flow rate measurements shall be made. For relatively constant flow rates only periodic... applicable to batch processes when the unit is in operation. Periodic sampling (grab samples) may be used... have a potential to release radionuclides into the air, periodic confirmatory measurements shall be...
Access to Bathtub Grab Bars: Evidence of a Policy Gap
ERIC Educational Resources Information Center
Birkett, Nicholas; Nair, Rama; Murphy, Maureen; Roberge, Ginette; Lockett, Donna
2006-01-01
This paper examines access to bathtub grab bars in privately and publicly owned apartment buildings and explores the profile of seniors who have access to bathtub grab bars. Results indicate that bathtub grab bars were significantly more prevalent in apartments that were publicly owned (91.3%) as compared to privately owned (37.8%) (p lesser than…
46 CFR 28.410 - Deck rails, lifelines, storm rails, and hand grabs.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 1 2011-10-01 2011-10-01 false Deck rails, lifelines, storm rails, and hand grabs. 28..., lifelines, storm rails, and hand grabs. (a) Except as otherwise provided in paragraph (d) of this section... with a bulwark, chain link fencing, wire mesh, or an equivalent. (f) A suitable storm rail or hand grab...
46 CFR 28.410 - Deck rails, lifelines, storm rails, and hand grabs.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 1 2014-10-01 2014-10-01 false Deck rails, lifelines, storm rails, and hand grabs. 28..., lifelines, storm rails, and hand grabs. (a) Except as otherwise provided in paragraph (d) of this section... with a bulwark, chain link fencing, wire mesh, or an equivalent. (f) A suitable storm rail or hand grab...
46 CFR 28.810 - Deck rails, lifelines, storm rails and hand grabs.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 1 2012-10-01 2012-10-01 false Deck rails, lifelines, storm rails and hand grabs. 28..., storm rails and hand grabs. (a) Except as otherwise provided in paragraph (d) of this section, deck... bulwark, chain link fencing, wire mesh, or an equivalent. (f) A suitable storm rail or hand grab must be...
46 CFR 28.810 - Deck rails, lifelines, storm rails and hand grabs.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 1 2011-10-01 2011-10-01 false Deck rails, lifelines, storm rails and hand grabs. 28..., storm rails and hand grabs. (a) Except as otherwise provided in paragraph (d) of this section, deck... bulwark, chain link fencing, wire mesh, or an equivalent. (f) A suitable storm rail or hand grab must be...
46 CFR 28.810 - Deck rails, lifelines, storm rails and hand grabs.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 1 2013-10-01 2013-10-01 false Deck rails, lifelines, storm rails and hand grabs. 28..., storm rails and hand grabs. (a) Except as otherwise provided in paragraph (d) of this section, deck... bulwark, chain link fencing, wire mesh, or an equivalent. (f) A suitable storm rail or hand grab must be...
46 CFR 28.410 - Deck rails, lifelines, storm rails, and hand grabs.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 1 2013-10-01 2013-10-01 false Deck rails, lifelines, storm rails, and hand grabs. 28..., lifelines, storm rails, and hand grabs. (a) Except as otherwise provided in paragraph (d) of this section... with a bulwark, chain link fencing, wire mesh, or an equivalent. (f) A suitable storm rail or hand grab...
46 CFR 28.410 - Deck rails, lifelines, storm rails, and hand grabs.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 1 2012-10-01 2012-10-01 false Deck rails, lifelines, storm rails, and hand grabs. 28..., lifelines, storm rails, and hand grabs. (a) Except as otherwise provided in paragraph (d) of this section... with a bulwark, chain link fencing, wire mesh, or an equivalent. (f) A suitable storm rail or hand grab...
46 CFR 28.410 - Deck rails, lifelines, storm rails, and hand grabs.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Deck rails, lifelines, storm rails, and hand grabs. 28..., lifelines, storm rails, and hand grabs. (a) Except as otherwise provided in paragraph (d) of this section... with a bulwark, chain link fencing, wire mesh, or an equivalent. (f) A suitable storm rail or hand grab...
46 CFR 28.810 - Deck rails, lifelines, storm rails and hand grabs.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Deck rails, lifelines, storm rails and hand grabs. 28..., storm rails and hand grabs. (a) Except as otherwise provided in paragraph (d) of this section, deck... bulwark, chain link fencing, wire mesh, or an equivalent. (f) A suitable storm rail or hand grab must be...
46 CFR 28.810 - Deck rails, lifelines, storm rails and hand grabs.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 1 2014-10-01 2014-10-01 false Deck rails, lifelines, storm rails and hand grabs. 28..., storm rails and hand grabs. (a) Except as otherwise provided in paragraph (d) of this section, deck... bulwark, chain link fencing, wire mesh, or an equivalent. (f) A suitable storm rail or hand grab must be...
30 CFR 280.30 - What activities will not require environmental analysis?
Code of Federal Regulations, 2010 CFR
2010-07-01
... types of activities include: (a) Gravity and magnetometric observations and measurements; (b) Bottom and..., including the setting of instruments; (g) Sampling by box core or grab sampler to determine seabed...
The report documents the technical approach and results achieved while developing a grab sampling method and an automated, on-line gas chromatography method suitable to characterize nitrous oxide (N2O) emissions from fossil fuel combustion sources. The two methods developed have...
Lake Michigan: Nearshore variability and a nearshore-offshore distinction in water quality
We conducted a high-resolution survey of the Lake Michigan nearshore using towed electronic instrumentation and fixed station sampling (1049 km at the approximate 20-m depth contour and grab samples at 15 sites). The principal variability in the alongshore reach was generally re...
VOCS IN AMBIENT AIR NEAR WORLD TRADE CENTER SITE
Beginning on September 22, 2001 and continuing through February 2002, ambient air samples were collected at three sites within a block of ground zero and at a fourth site on the 16th floor of a building at 290 Broadway. Grab samples were collected in evacuated, electro-polished...
40 CFR 61.174 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Arsenic Emissions From Primary Copper Smelters § 61.174 Test methods and procedures. (a) To determine... converter arsenic charging rate as follows: (1) Collect daily grab samples of copper matte and any lead... determine the weight percent of inorganic arsenic contained in each sample. (3) Calculate the converter...
Comparison of Grab, Air, and Surface Results for Radiation Site Characterization
NASA Astrophysics Data System (ADS)
Glassford, Eric Keith
2011-12-01
The use of proper sampling methods and sample types for evaluating sites believed to be contaminated with radioactive materials is necessary to avoid misrepresenting conditions at the site. This study was designed to investigate if the site characterization, based upon uranium contamination measured in different types of samples, is dependent upon the mass of the sample collected. A bulk sample of potentially contaminated interior dirt was collected from an abandoned metal processing mill that rolled uranium between 1948 and 1956. The original mill dates from 1910 and has a dirt floor. The bulk sample was a mixture of dirt, black and yellow particles of metal dust, and small fragments of natural debris. Small mass (approximately 0.75 grams (g)) and large mass (approximately 70g) grab samples were prepared from the bulk sample material to simulate collection of a "grab" type sample. Air sampling was performed by re-suspending a portion of the bulk sample material using a vibration table to simulate airborne contamination that might be present during site remediation. Additionally, samples of removable contaminated surface dust were collected on 47 mm diameter filter paper by wiping the surfaces of the exposure chamber used to resuspend the bulk material. Certified reference materials, one containing a precisely known quantity of U 3O8 and one containing a known quantity of natural uranium, were utilized to calibrate the gamma spectrometry measurement system. Non-destructive gamma spectrometry measurements were used to determine the content of uranium-235 (235U) at 185 keV and 143 keV, thorium-234 (234Th) at 63 keV, and protactinium-234m (234mPa) at 1001 keV in each sample. Measurement of natural uranium in small, 1 g samples is usually accomplished by radiochemical analysis in order to measure alpha particles emitted by 238U, 235U, and 234U. However, uranium in larger bulk samples can also be measured non-destructively using gamma spectrometry to detect the low energy photons from 234Th and 234mPa, the short-lived decay products of 238U, and 235U. Two sided t-tests and coefficient of variation were used to compare sampling types. The large grab samples had the lowest calculated coefficient of variation results for activity and atom percentage. The wipe samples had the highest calculated coefficient of variation of mean specific activity (dis/sec/g) for all three energies. The air filter samples had the highest coefficient of variation calculation for mean atom percentage, for both uranium isotopes examined. The data indicated that the large mass sample was the most effective at characterizing the rolling mill radioactive site conditions, since this would indicate which samples had the smallest variations compared to the mean. Additionally, measurement results of natural uranium in the samples indicate that the distribution of radioactive contamination at the sampling location is most likely non-homogeneous and that the size of the sample collected and analyzed must be sufficiently large to insure that the analytical results are truly representative of the activity present.
NASA Technical Reports Server (NTRS)
James, John T.
2012-01-01
One mini-grab sample container (m-GSC) was returned aboard Space X1 because of the importance of quickly knowing first-entry conditions in this new commercial module. This sample was analyzed alongside samples of the portable clean room (PCR) used in the Space X complex at KSC. The recoveries of C-13-acetone, fluorobenzene, and chlorobenzene from the GSCs averaged 130, 129, and 132 %, respectively.
USDA-ARS?s Scientific Manuscript database
High frequency in situ measurements of nitrate can greatly reduce the uncertainty in nitrate flux estimates. Water quality databases maintained by various federal and state agencies often consist of pollutant concentration data obtained from periodic grab samples collected from gauged reaches of a s...
Jones-Lepp, Tammy L.; Sanchez, Charles; Alvarez, David A.; Wilson, Doyle C.; Taniguchi-Fu, Randi-Laurant
2012-01-01
Emerging contaminants (ECs) (e.g., pharmaceuticals, illicit drugs, personal care products) have been detected in waters across the United States. The objective of this study was to evaluate point sources of ECs along the Colorado River, from the headwaters in Colorado to the Gulf of California. At selected locations in the Colorado River Basin (sites in Colorado, Utah, Nevada, Arizona, and California), waste stream tributaries and receiving surface waters were sampled using either grab sampling or polar organic chemical integrative samplers (POCIS). The grab samples were extracted using solid-phase cartridge extraction (SPE), and the POCIS sorbents were transferred into empty SPEs and eluted with methanol. All extracts were prepared for, and analyzed by, liquid chromatography–electrospray-ion trap mass spectrometry (LC–ESI-ITMS). Log DOW values were calculated for all ECs in the study and compared to the empirical data collected. POCIS extracts were screened for the presence of estrogenic chemicals using the yeast estrogen screen (YES) assay. Extracts from the 2008 POCIS deployment in the Las Vegas Wash showed the second highest estrogenicity response. In the grab samples, azithromycin (an antibiotic) was detected in all but one urban waste stream, with concentrations ranging from 30 ng/L to 2800 ng/L. Concentration levels of azithromycin, methamphetamine and pseudoephedrine showed temporal variation from the Tucson WWTP. Those ECs that were detected in the main surface water channels (those that are diverted for urban use and irrigation along the Colorado River) were in the region of the limit-of-detection (e.g., 10 ng/L), but most were below detection limits.
NASA Astrophysics Data System (ADS)
Tang, Meiling; Wen, Guiqing; Luo, Yanghe; Liang, Aihui; Jiang, Zhiliang
2015-01-01
AuRu nanoalloy (GR) with Au/Ru molar ratio of 32/1 was prepared by the sodium borohydride reduction method. It was used to label the CA125 antibody (Ab) to obtain an immunonanoprobe (GRAb) for cancer antigen 125 (CA125). In pH 7.0 citric acid-Na2HPO4 buffer solution and irradiation of ultrasound, the probes were aggregated nonspecifically to big clusters that showed a strong resonance Rayleigh scattering (RRS) peak at 278 nm. Upon addition of CA125, GRAb reacted specifically with CA125 to form dispersive immunocomplexes of CA125-GRAb in the solution and this process enhanced by the ultrasonic cavitation effect, which led to the RRS intensity decreased greatly. The decreased RRS intensity was linear to the concentration of CA125 in the range of 1.3-80 U/mL, with a detection limit of 0.6 U/mL. The proposed method was applied to detect CA125 in real sample, with satisfactory results.
NASA Astrophysics Data System (ADS)
Carey, R. O.; Wollheim, W. M.; Mulukutla, G. K.; Cook, C. S.
2013-12-01
Management of non-point sources is challenging because it requires adequate quantification of non-point fluxes that are highly dynamic over time. Most fluxes occur during storms and are difficult to characterize with grab samples alone in flashy, urban watersheds. Accurate and relatively precise measurements using in situ sensor technology can quantify fluxes continuously, avoiding the uncertainties in extrapolation of infrequently collected grab samples. In situ nitrate (NO3-N) sensors were deployed simultaneously from April to December 2013 in two streams with contrasting urban land uses in an urbanizing New Hampshire watershed (80 km2). Nitrogen non-point fluxes and temporal patterns were evaluated in Beards Creek (forested: 50%; residential: 24%; commercial/institutional/transportation: 7%; agricultural: 6%) and College Brook (forested: 35%; residential: 11%; commercial/institutional/transportation: 20%; agricultural: 17%). Preliminary data indicated NO3-N concentrations in Beards Creek (mean: 0.37 mg/L) were lower than College Brook (mean: 0.60 mg/L), but both streams exhibited rapid increases in NO3-N during the beginning of storms followed by overall dilution. While baseflow NO3-N was greater in College Brook than Beards Creek, NO3-N at the two sites consistently converged during storms. This suggests that standard grab sampling may overestimate fluxes in urban streams, since short-term dilution occurred during periods of highest flow. Analyzing NO3-N flux patterns in smaller urban streams that are directly impacted by watershed activities could help to inform management decisions regarding N source controls, ultimately allowing an assessment of the interactions of climate variability and management actions.
Visual Attention to Antismoking PSAs: Smoking Cues versus Other Attention-Grabbing Features
ERIC Educational Resources Information Center
Sanders-Jackson, Ashley N.; Cappella, Joseph N.; Linebarger, Deborah L.; Piotrowski, Jessica Taylor; O'Keeffe, Moira; Strasser, Andrew A.
2011-01-01
This study examines how addicted smokers attend visually to smoking-related public service announcements (PSAs) in adults smokers. Smokers' onscreen visual fixation is an indicator of cognitive resources allocated to visual attention. Characteristic of individuals with addictive tendencies, smokers are expected to be appetitively activated by…
Young, Stacie T.M.; Jamison, Marcael T.J.
2007-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data were collected at two stations, continuous streamflow data at three stations, and water-quality data at five stations, which include the two continuous streamflow stations. This report summarizes rainfall, streamflow, and water-quality data collected between July 1, 2006 and June 30, 2007. A total of 13 samples was collected over two storms during July 1, 2006 to June 30, 2007. The goal was to collect grab samples nearly simultaneously at all five stations and flow-weighted time-composite samples at the three stations equipped with automatic samplers. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). Additionally, grab samples were analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/quality-control samples were also collected during storms and during routine maintenance to verify analytical procedures and check the effectiveness of equipment-cleaning procedures.
Bias of Tedlar bags in the measurement of agricultural odorants.
Trabue, Steven L; Anhalt, Jennifer C; Zahn, James A
2006-01-01
Odor regulations typically specify the use of dynamic dilution olfactometery (DDO) as a method to quantify odor emissions, and Tedlar bags are the preferred holding container for grab samples. This study was conducted to determine if Tedlar bags affect the integrity of sampled air from animal operations. Air samples were collected simultaneously in both Tedlar bags and Tenax thermal desorption tubes. Sample sources originated from either a hydrocarbon-free air tank, dynamic headspace chamber (DHC), or swine-production facility, and were analyzed by gas chromatography-mass spectrometry-olfactometry (GC-MS-O). Several background contaminants were identified from Tedlar bags, which included the odorous compounds N,N-dimethyl acetamide (DMAC), acetic acid, and phenol. Samples from the DHC demonstrated that recovery of malodor compounds was dependent on residence time in the Tedlar bag with longer residence time leading to lower recovery. After 24 h of storage, recovery of C3-C6 volatile fatty acids (VFA) averaged 64%, 4-methylphenol and 4-ethylphenol averaged 10%, and indole and 3-methylindole were below the detection limits of GC-MS-O. The odor activity value (OAV) of grab samples collected in Tedlar bags were 33 to 65% lower following 24 h of storage. These results indicate that significant odorant bias occurs when using Tedlar bags for the sampling of odors from animal production facilities.
40 CFR 98.264 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... requirements. (a) You must obtain a monthly grab sample of phosphate rock directly from the rock being fed to... Methods Used and Adopted by the Association of Fertilizer and Phosphate Chemists (AFPC). If phosphate rock is obtained from more than one origin in a month, you must obtain a sample from each origin of rock...
40 CFR 98.264 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... requirements. (a) You must obtain a monthly grab sample of phosphate rock directly from the rock being fed to..., Bartow, Florida 33831, (863) 534-9755, http://afpc.net, [email protected]). If phosphate rock is obtained from more than one origin in a month, you must obtain a sample from each origin of rock or obtain...
40 CFR 98.264 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... requirements. (a) You must obtain a monthly grab sample of phosphate rock directly from the rock being fed to..., Bartow, Florida 33831, (863) 534-9755, http://afpc.net, [email protected]). If phosphate rock is obtained from more than one origin in a month, you must obtain a sample from each origin of rock or obtain...
40 CFR 98.264 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... requirements. (a) You must obtain a monthly grab sample of phosphate rock directly from the rock being fed to..., Bartow, Florida 33831, (863) 534-9755, http://afpc.net, [email protected]). If phosphate rock is obtained from more than one origin in a month, you must obtain a sample from each origin of rock or obtain...
VOLATILE ORGANIC COMPOUNDS MEASUREMENTS IN NEW YORK CITY IN RESPONSE TO THE EVENTS OF 9/11
From September 22, 2001 through February 2002, ambient air was sampled in lower Manhattan, New York at three sites within a block of ground zero and at a fourth site 500-m northwest of the World Trade Center. Over 190 grab samples were collected in evacuated, electro-polished s...
Soyuz 25 Return Samples: Assessment of Air Quality Aboard the International Space Station
NASA Technical Reports Server (NTRS)
James, John T.
2011-01-01
Six mini-grab sample containers (m-GSCs) were returned aboard Soyuz 25. The toxicological assessment of 6 m-GSCs from the ISS is shown. The recoveries of the 3 internal standards, C-13-acetone, fluorobenzene, and chlorobenzene, from the GSCs averaged 76, 108 and 88%, respectively. Formaldehyde badges were not returned aboard Soyuz 25.
NASA Technical Reports Server (NTRS)
James, John T.
2009-01-01
The toxicological assessments of 2 grab sample canisters (GSCs) from the Shuttle are reported. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 GSCs averaged 106, 106, and 101 %,respectively. Based on the end-of-mission sample, the Shuttle atmosphere was acceptable for human respiration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
REICH, F.R.
The PHMC will provide Low Activity Wastes (LAW) tank wastes for final treatment by a privatization contractor from two double-shell feed tanks, 241-AP-102 and 241-AP-104. Concerns about the inability of the baseline ''grab'' sampling to provide large volume samples within time constraints has led to the development of a nested, fixed-depth sampling system. This sampling system will provide large volume, representative samples without the environmental, radiation exposure, and sample volume impacts of the current base-line ''grab'' sampling method. A plan has been developed for the cold testing of this nested, fixed-depth sampling system with simulant materials. The sampling system willmore » fill the 500-ml bottles and provide inner packaging to interface with the Hanford Sites cask shipping systems (PAS-1 and/or ''safe-send''). The sampling system will provide a waste stream that will be used for on-line, real-time measurements with an at-tank analysis system. The cold tests evaluate the performance and ability to provide samples that are representative of the tanks' content within a 95 percent confidence interval, to sample while mixing pumps are operating, to provide large sample volumes (1-15 liters) within a short time interval, to sample supernatant wastes with over 25 wt% solids content, to recover from precipitation- and settling-based plugging, and the potential to operate over the 20-year expected time span of the privatization contract.« less
Mendenhall, E; Muzizi, L; Stephenson, R; Chomba, E; Ahmed, Y; Haworth, A; Allen, S
2007-03-01
High rates of HIV and poverty place women in a precarious economic situation in Lusaka, Zambia. Mortality from HIV infection is high, leaving many households single headed and creating almost a half a million orphans. One of the most prevalent forms of gender violence that creates poverty in women is when the male's family claims the property of the deceased from the widow and the children. The Zambia-Emory HIV Research Project collected 184 wills from individuals in monogamous unions where one or both of the individuals were HIV-positive. Despite the fact that many wills specifically stated that their extended family was not allowed to tamper with their possessions in the event of death, property grabbing proved to be a prevalent and difficult issue in Lusaka. In order to improve the lives of widowed women in Lusaka, the government and other civic and non-governmental organisations must inform women of their rights to own and protect their land and other assets in the event of their husbands' death, an issue of increasing importance in the area of HIV/AIDS.
Zenobio, Jenny E; Sanchez, Brian C; Leet, Jessica K; Archuleta, Laura C; Sepúlveda, Maria S
2015-02-01
Pharmaceuticals and personal care products (PPCPs) have raised concerns due to their potential effects to aquatic organisms. These chemicals appear in mixtures at very low concentrations thus making their detection and quantification difficult. Polar organic chemical integrative samplers (POCIS) concentrate trace levels of chemicals over time increasing method sensitivity and thus represent a cost-effective screening tool for biomonitoring studies. The Baca National Wildlife Refuge (BNWR), Colorado, is home for several endemic fish species, including Rio Grande chub (Gila pandora). The objectives of this study were to (1) determine the types and concentrations of PPCPs in the Refuge, (2) compare and contrast two methods (grab and POCIS) for the quantification of PPCPs from surface water, and (3) determine effects due to PPCP exposure in fish. Between 2011 and 2013, 141 PPCPs were quantified using a combination of grab samples and POCIS. Although no PPCPs were detected from the grab samples, high concentrations of N,N-Diethyl-meta-toluamide (DEET) and triclosan were detected in all fish sampling sites with POCIS. Fathead minnows (Pimephales promelas) and Rio Grande chubs of both sexes were collected in 2011 and 2012. Several biological responses were observed in both species from creeks contaminated with PPCPs; however the presence of PPCPs in the reference site did not allow for valid data comparison and interpretation. We conclude that POCIS is a sensitive method for the detection and quantification of PPCPs and for identification of reference sites and that appropriate "reference" sites need to be identified at the BNWR for follow-up studies with native fish. Copyright © 2014 Elsevier Ltd. All rights reserved.
2013-06-01
lenses of unconsolidated sand and rounded river gravel overlain by as much as 5 m of silt. Gravel consists mostly of quartz and metamorphic rock with...iii LIST OF FIGURES Page Figure 1. Example of multi-increment sampling using a systematic-random sampling design for collecting two separate...The small arms firing Range 16 Record berms at Fort Wainwright. .................... 25 Figure 9. Location of berms sampled using ISM and grab
Okkenhaug, G; Almås, Å R; Morin, N; Hale, S E; Arp, H P H
2015-11-01
The environmental behaviour of antimony (Sb) is gathering attention due to its increasingly extensive use in various products, particularly in plastics. Because of this it may be expected that plastic waste is an emission source for Sb in the environment. This study presents a comprehensive field investigation of Sb concentrations in diverse types of waste from waste handling facilities in Norway. The wastes included waste electrical and electronic equipment (WEEE), glass, vehicle fluff, combustibles, bottom ash, fly ash and digested sludge. The highest solid Sb concentrations were found in WEEE and vehicle plastic (from 1238 to 1715 mg kg(-1)) and vehicle fluff (from 34 to 4565 mg kg(-1)). The type of acid used to digest the diverse solid waste materials was also tested. It was found that HNO3:HCl extraction gave substantially lower, non-quantitative yields compared to HNO3:HF. The highest water-leachable concentration for wastes when mixed with water at a 1 : 10 ratio were observed for plastic (from 0.6 to 2.0 mg kg(-1)) and bottom ash (from 0.4 to 0.8 mg kg(-1)). For all of the considered waste fractions, Sb(v) was the dominant species in the leachates, even though Sb(iii) as Sb2O3 is mainly used in plastics and other products, indicating rapid oxidation in water. This study also presents for the first time a comparison of Sb concentrations in leachate at waste handling facilities using both active grab samples and DGT passive samples. Grab samples target the total suspended Sb, whereas DGT targets the sum of free- and other chemically labile species. The grab sample concentrations (from 0.5 to 50 μg L(-1)) were lower than the predicted no-effect concentration (PNEC) of 113 μg L(-1). The DGT concentrations were substantially lower (from 0.05 to 9.93 μg L(-1)) than the grab samples, indicating much of the Sb is present in a non-available colloidal form. In addition, air samples were taken from the chimney and areas within combustible waste incinerators, as well as from the vent of WEEE sorting facility. The WEEE vent had the highest Sb concentration (from <100 to 2200 ng m(-3)), which were orders of magnitude higher than the air surrounding the combustible shredder (from 25 to 217 ng m(-3)), and the incinerator chimney (from <30 to 100 ng m(-3)). From these results, it seems evident that Sb from waste is not an environmental concern in Norway, and that Sb is mostly readily recovered from plastic and bottom ash.
Grab a Byte. Courseware Evaluation for Vocational and Technical Education.
ERIC Educational Resources Information Center
Rosenfeld, Vila M.; And Others
This courseware evaluation rates the "Grab a Byte" program developed by tne National Dairy Council. (The program--not included in this document--is divided into three sections: Grab-a-Grape uses a quiz-show format to examine students' knowledge of food groups; Nutrition Sleuth reinforces students' nutrient knowledge; and Have-a-Byte…
Capacity for DNA-barcode based taxonomy in support of Great Lakes biological monitoring
Enumerating organisms collected via nets and sediment grabs is a mainstay of aquatic ecology. Since morphological taxonomy can require considerable resources and expertise, DNA barcode-based identification of mixed-organism samples offers a valuable tool in support of biological...
Grosz, A.E.
1987-01-01
The US is dependent on foreign imports of placer heavy minerals for a majority of its ilmenite and rutile, and virtually all of its monazite requirements. Although sand deposits in the SE US are important domestic sources of these heavy minerals (HM) and a number of other less well-known heavy-mineral species, global onshore reserves of placer minerals may fall short of demand in as few as 20 years. Insofar as they are important commodities for the future, offshore HM placers will become more important, but much research on them remains to be done. Results of recent offshore studies, based on surficial grab samples, indicate an average of about 2 weight percent HM in surficial Atlantic Continental Shelf (ACS) sediments, in strong contrast with previous estimates of an average of 0.16% HM. Although provocative, the information from these grab samples does not include the thickness of the HM deposits and thus their volume and tonnage cannot be estimated.-from Author
New estimates of nitrous oxide emissions from biomass burning
NASA Technical Reports Server (NTRS)
Cofer, W. R., III; Levine, J. S.; Winstead, E. L.; Stocks, B. J.
1991-01-01
The recent discovery of an artifact producing increased levels of N2O in combustion gas samples collected and stored in grab bottles before chemical analysis has resulted in the downgrading of fossil-fuel combustion and the questioning of biomass burning as important sources of N2O. As almost all reported analyses of N2O produced from biomass burning have involved essentially the same collection and analysis protocols as used in the fossil-fuel studies, this source of N2O must also be reexamined. Here, measurements of N2O made over a large prescribed fire using a near real-time in situ measurement technique are reported and compared with measurements of N2O from simultaneously collected grab-bottle samples. The results from 27 small laboratory biomass test fires are also used to help clarify the validity of earlier assessments. It is concluded that biomass burning contributes about seven percent of atmospheric N2O, as opposed to earlier estimates of several times this value.
NASA Technical Reports Server (NTRS)
James, John T.
2010-01-01
The toxicological assessments of 3 grab sample canisters (GSCs) from the Shuttle are reported in Table 1. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates ( 13C-acetone, fluorobenzene, and chlorobenzene) from the 3 Shuttle GSCs averaged 96, 90, and 85 %, respectively. Based on the end-of-mission sample, the Shuttle atmosphere was acceptable for human respiration.
Young, Stacie T.M.; Ball, Marcael T.J.
2005-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data were collected at two stations, continuous streamflow data at two stations, and water-quality data at five stations, which include the two continuous streamflow stations. This report summarizes rainfall, streamflow, and water-quality data collected between July 1, 2004 and June 30, 2005. A total of 15 samples was collected over three storms during July 1, 2004 to June 30, 2005. In general, an attempt was made to collect grab samples nearly simultaneously at all five stations and flow-weighted time-composite samples at the three stations equipped with automatic samplers. However, all three storms were partially sampled because either not all stations were sampled or not all composite samples were collected. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). Chromium and nickel were added to the analysis starting October 1, 2004. Grab samples were additionally analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/quality-control samples were also collected during storms and during routine maintenance to verify analytical procedures and check the effectiveness of equipment-cleaning procedures.
Scudder Eikenberry, Barbara C.; Burns, Daniel J.; Olds, Hayley T.; Bell, Amanda H.; Mapel, Kassidy T.
2016-06-15
Benthos (benthic invertebrates) and plankton (zooplankton and phytoplankton) communities were sampled in 2014 at 10 Wisconsin rivers and harbors, including 4 sites in Great Lakes Areas of Concern and 6 less degraded comparison sites with similar physical and chemical characteristics, including climate, latitude, geology, and land use. Previous U.S. Geological Survey sampling was completed in 2012, but because of ongoing sediment remediation at three of the Areas of Concern (AOCs) and unusually hot and dry conditions in many areas during 2012, additional sampling was added in 2014. Comparable sampling methods were used in 2012 and 2014. Benthos were collected by using Hester-Dendy artificial substrate samplers and composite Ponar grab samples of bottom sediment; zooplankton were collected by using tows from depth to the surface with a 63-micrometer mesh plankton net; phytoplankton were collected by using whole water samples composited from set depth intervals. This report describes the study areas and field sampling methods for 2014, and it presents data on taxonomic identification and abundance of benthos and plankton that can serve as a basis for evaluation of related Beneficial Use Impairments (BUIs) at the AOCs. Physical and chemical data were sampled concurrently (specific conductance, temperature, pH, dissolved oxygen, chlorophyll a, total and volatile suspended solids in water samples; particle size and volatile-on-ignition of sediment in benthic grab samples). The results of field quality assurance-quality control are also presented.
Modeled De Facto Reuse and Contaminants of Emerging Concern in Drinking Water Source Waters
De facto reuse is the percentage of drinking water treatment plant (DWTP) intake potentially composed of effluent discharged from upstream wastewater treatment plants (WWTPs). Results from grab samples and a De Facto Reuse in our Nation's Consumable Supply (DRINCS) geospatial wat...
NATIONAL SCREENING SURVEY OF EDCS IN MUNICIPAL WASTEWATER TREATMENT FACILITIES
In 2002 and 2003 the USEPA's Office of Research and Development asked Regional EPA inspectors, state EPA inspectors and municipal plant operators to collect four gallons effluent, either as a grab or composite sample, from up to 50 wastewater treatment plants (WWTP), and ship the...
Velásquez, A V; da Silva, G G; Sousa, D O; Oliveira, C A; Martins, C M M R; Dos Santos, P P M; Balieiro, J C C; Rennó, F P; Fukushima, R S
2018-04-18
Feed intake assessment is a valuable tool for herd management decisions. The use of markers, either internal or external, is currently the most used technique for estimating feed intake in production animals. The experiment used 10 multiparous Holstein cows fed a corn silage-based diet, with 55:45 forage-to-concentrate ratio, the average fecal recovery (FR) of TiO 2 was higher than FR of Cr 2 O 3 , and both FR were more than unity. With internal markers, acetyl bromide lignin and cutin FR were lower than unity, and average FR for indigestible neutral detergent fiber (iNDF) and indigestible acid detergent fiber (iADF) was 1.5. The FR was unaffected by the fecal sampling procedure and appears to be an intrinsic property of each molecule and how it interacts with digesta. Of the 2 external markers, only Cr 2 O 3 produced accurate fecal output (FO) estimates and the same happened to dry matter digestibility (DMD) when iNDF and iADF were used. Estimates for DMD and FO were affected by sampling procedure; 72-h bulk [sub-sample from total feces collection (TFC)] sampling consistently produced accurate results. The grab (sub-samples taken at specific times during the day) sampling procedures were accurate when using either of the indigestible fibers (iNDF or iADF) to estimate DMD. However, grab sampling procedures can only be recommended when concomitant TFC is performed on at least one animal per treatment to determine FR. Under these conditions, Cr 2 O 3 is a suitable marker for estimating FO, and iNDF and iADF are adequate for estimating DMD. Moreover, the Cr 2 O 3 +iADF marker pair produces accurate dry matter intake estimates and deserves further attention in ruminant nutrition studies. The method of dosing the external markers is extremely important and greatly affects and determines results. Whichever the method, it must allow the animals to display normal feeding behavior and not affect performance. The grab sampling procedures can replace TFC (once FR is established), which may open new possibilities for pasture-based or collectively housed animals. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
James, John T.
2010-01-01
The toxicological assessments of 1 grab sample canister (GSC) from the Shuttle are reported in Table 1. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the Shuttle GSC were 100%, 93%, and 101%, respectively. Based on the historical experience using end-of-mission samples, the Shuttle atmosphere was acceptable for human respiration.
NASA Astrophysics Data System (ADS)
Zalmon, I. R.; Macedo, I. M.; Rezende, C. E.; Falcão, A. P. C.; Almeida, T. C.
2013-09-01
The environmental heterogeneity of the Campos Basin on the northern coast of Rio de Janeiro State was assessed by the benthic macrofauna on the platform adjacent to the Paraíba do Sul River (PSR) on the dry and rainy seasons. The samples were collected in triplicate from 33 sites using a van Veen grab during March 2009 - a period of higher precipitation and flow rate - and July 2009 - a period of lower precipitation and flow rate. The grab depths ranged from 12 to 97 m and were grouped into three strata: 1: <25 m, 2: 25-50 m and 3: >50 m. The particle size, total carbonate and total organic carbon in each sample were analyzed. Subsamples for the macrofauna analysis were washed, sieved with a 500 μm mesh and identified. The sediment was predominantly composed of sand, with mud pockets near the mouth of the river. The macrofauna included annelids, crustaceans, mollusks, echinoderms, cnidarians, nemerteans, cephalochordates, sipunculids and bryozoans. The density and richness were directly related to the depth, with both descriptors being higher during the rainy season and at depths greater than 50 m. This result is probably due to the higher availability of food in the river during this period and is corroborated by the predominance of deposit feeders in the deepest stratum. The number of individuals of each species was higher in the shallowest stratum, probably due to the higher productivity of this stratum. The rate of organic particulate matter flow from the coastal regions to the deeper regions can also be influenced by the material export dynamics of the river, which are more intense during the rainy season. These dynamics explain why a significantly higher number of individuals were observed in the rainy period in comparison to the dry one. Multivariate analyses identified differences between the sampling sites in the deepest stratum during both periods and revealed a stronger similarity between the shallow and intermediate strata, especially during the rainy season, which has a higher flow rate. These findings reinforce the influence of the Paraíba do Sul River on the structural pattern and composition of the benthic macrofauna of the internal platform (<50 m) on the northern coast of Rio de Janeiro.
Fathead minnows (Pimephales promelas) were caged for four days at multiple locations upstream and downstream of a wastewater treatment plant (WWTP) discharge into the Maumee River (USA, OH). Grab water samples collected at the same location were extracted using several different ...
40 CFR 90.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2012 CFR
2012-07-01
... detector (HFID) for the measurement of hydrocarbons, non-dispersive infrared analyzers (NDIR) for the... converted to nitric oxide before analysis. Other types of analyzers may be used if shown to yield equivalent... room temperature, produces an equivalent CO response, as measured on the most sensitive CO range, which...
40 CFR 90.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2010 CFR
2010-07-01
... detector (HFID) for the measurement of hydrocarbons, non-dispersive infrared analyzers (NDIR) for the... converted to nitric oxide before analysis. Other types of analyzers may be used if shown to yield equivalent... room temperature, produces an equivalent CO response, as measured on the most sensitive CO range, which...
40 CFR 90.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2014 CFR
2014-07-01
... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS... detector (HFID) for the measurement of hydrocarbons, non-dispersive infrared analyzers (NDIR) for the... converted to nitric oxide before analysis. Other types of analyzers may be used if shown to yield equivalent...
40 CFR 90.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19... detector (HFID) for the measurement of hydrocarbons, non-dispersive infrared analyzers (NDIR) for the... converted to nitric oxide before analysis. Other types of analyzers may be used if shown to yield equivalent...
40 CFR 90.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19... detector (HFID) for the measurement of hydrocarbons, non-dispersive infrared analyzers (NDIR) for the... converted to nitric oxide before analysis. Other types of analyzers may be used if shown to yield equivalent...
Stratospheric CCN sampling program. [volcanology, Mount Saint Helens
NASA Technical Reports Server (NTRS)
Rogers, C. F.; Hudson, J. G.
1982-01-01
Two one liter grab samples of stratospheric aerosol were returned from each of six U-2 sampling missions. Cloud condensation nuclei (CCN) spectra from each sample were obtained. Interest was centered on the effects of volcanic activity. Spurious particle generation was found to be a serious problem in container 9 LFT and a much smaller problem in container 9 RT. Initial studies of an option for improved sample containers and values were completed. A CCN spectrometer, able to operate at an internal pressure of 300 mb, was designed.
Interlinking backscatter, grain size and benthic community structure
NASA Astrophysics Data System (ADS)
McGonigle, Chris; Collier, Jenny S.
2014-06-01
The relationship between acoustic backscatter, sediment grain size and benthic community structure is examined using three different quantitative methods, covering image- and angular response-based approaches. Multibeam time-series backscatter (300 kHz) data acquired in 2008 off the coast of East Anglia (UK) are compared with grain size properties, macrofaunal abundance and biomass from 130 Hamon and 16 Clamshell grab samples. Three predictive methods are used: 1) image-based (mean backscatter intensity); 2) angular response-based (predicted mean grain size), and 3) image-based (1st principal component and classification) from Quester Tangent Corporation Multiview software. Relationships between grain size and backscatter are explored using linear regression. Differences in grain size and benthic community structure between acoustically defined groups are examined using ANOVA and PERMANOVA+. Results for the Hamon grab stations indicate significant correlations between measured mean grain size and mean backscatter intensity, angular response predicted mean grain size, and 1st principal component of QTC analysis (all p < 0.001). Results for the Clamshell grab for two of the methods have stronger positive correlations; mean backscatter intensity (r2 = 0.619; p < 0.001) and angular response predicted mean grain size (r2 = 0.692; p < 0.001). ANOVA reveals significant differences in mean grain size (Hamon) within acoustic groups for all methods: mean backscatter (p < 0.001), angular response predicted grain size (p < 0.001), and QTC class (p = 0.009). Mean grain size (Clamshell) shows a significant difference between groups for mean backscatter (p = 0.001); other methods were not significant. PERMANOVA for the Hamon abundance shows benthic community structure was significantly different between acoustic groups for all methods (p ≤ 0.001). Overall these results show considerable promise in that more than 60% of the variance in the mean grain size of the Clamshell grab samples can be explained by mean backscatter or acoustically-predicted grain size. These results show that there is significant predictive capacity for sediment characteristics from multibeam backscatter and that these acoustic classifications can have ecological validity.
Williams, Maggie R; Stedtfeld, Robert D; Engle, Cathrine; Salach, Paul; Fakher, Umama; Stedtfeld, Tiffany; Dreelin, Erin; Stevenson, R Jan; Latimore, Jo; Hashsham, Syed A
2017-01-01
Loop-mediated isothermal amplification (LAMP) of aquatic invasive species environmental DNA (AIS eDNA) was used for rapid, sensitive, and specific detection of Dreissena sp. relevant to the Great Lakes (USA) basin. The method was validated for two uses including i) direct amplification of eDNA using a hand filtration system and ii) confirmation of the results after DNA extraction using a conventional thermal cycler run at isothermal temperatures. Direct amplification eliminated the need for DNA extraction and purification and allowed detection of target invasive species in grab or concentrated surface water samples, containing both free DNA as well as larger cells and particulates, such as veligers, eggs, or seeds. The direct amplification method validation was conducted using Dreissena polymorpha and Dreissena bugensis and uses up to 1 L grab water samples for high target abundance (e.g., greater than 10 veligers (larval mussels) per L for Dreissena sp.) or 20 L samples concentrated through 35 μm nylon screens for low target abundance, at less than 10 veligers per liter water. Surface water concentrate samples were collected over a period of three years, mostly from inland lakes in Michigan with the help of a network of volunteers. Field samples collected from 318 surface water locations included i) filtered concentrate for direct amplification validation and ii) 1 L grab water sample for eDNA extraction and confirmation. Though the extraction-based protocol was more sensitive (resulting in more positive detections than direct amplification), direct amplification could be used for rapid screening, allowing for quicker action times. For samples collected between May and August, results of eDNA direct amplification were consistent with known presence/absence of selected invasive species. A cross-platform smartphone application was also developed to disseminate the analyzed results to volunteers. Field tests of the direct amplification protocol using a portable device (Gene-Z) showed the method could be used in the field to obtain results within one hr (from sample to result). Overall, the direct amplification has the potential to simplify the eDNA-based monitoring of multiple aquatic invasive species. Additional studies are warranted to establish quantitative correlation between eDNA copy number, veliger, biomass or organismal abundance in the field.
Stedtfeld, Robert D.; Engle, Cathrine; Salach, Paul; Fakher, Umama; Stedtfeld, Tiffany; Dreelin, Erin; Stevenson, R. Jan; Latimore, Jo; Hashsham, Syed A.
2017-01-01
Loop-mediated isothermal amplification (LAMP) of aquatic invasive species environmental DNA (AIS eDNA) was used for rapid, sensitive, and specific detection of Dreissena sp. relevant to the Great Lakes (USA) basin. The method was validated for two uses including i) direct amplification of eDNA using a hand filtration system and ii) confirmation of the results after DNA extraction using a conventional thermal cycler run at isothermal temperatures. Direct amplification eliminated the need for DNA extraction and purification and allowed detection of target invasive species in grab or concentrated surface water samples, containing both free DNA as well as larger cells and particulates, such as veligers, eggs, or seeds. The direct amplification method validation was conducted using Dreissena polymorpha and Dreissena bugensis and uses up to 1 L grab water samples for high target abundance (e.g., greater than 10 veligers (larval mussels) per L for Dreissena sp.) or 20 L samples concentrated through 35 μm nylon screens for low target abundance, at less than 10 veligers per liter water. Surface water concentrate samples were collected over a period of three years, mostly from inland lakes in Michigan with the help of a network of volunteers. Field samples collected from 318 surface water locations included i) filtered concentrate for direct amplification validation and ii) 1 L grab water sample for eDNA extraction and confirmation. Though the extraction-based protocol was more sensitive (resulting in more positive detections than direct amplification), direct amplification could be used for rapid screening, allowing for quicker action times. For samples collected between May and August, results of eDNA direct amplification were consistent with known presence/absence of selected invasive species. A cross-platform smartphone application was also developed to disseminate the analyzed results to volunteers. Field tests of the direct amplification protocol using a portable device (Gene-Z) showed the method could be used in the field to obtain results within one hr (from sample to result). Overall, the direct amplification has the potential to simplify the eDNA-based monitoring of multiple aquatic invasive species. Additional studies are warranted to establish quantitative correlation between eDNA copy number, veliger, biomass or organismal abundance in the field. PMID:29036210
DOE Office of Scientific and Technical Information (OSTI.GOV)
CALLAWAY WS; HUBER HJ
Based on an ENRAF waste surface measurement taken February 1, 2009, double-shell tank (DST) 241-AN-106 (AN-106) contained approximately 278.98 inches (793 kgal) of waste. A zip cord measurement from the tank on February 1, 2009, indicated a settled solids layer of 91.7 inches in height (280 kgal). The supernatant layer in February 2009, by difference, was approximately 187 inches deep (514 kgal). Laboratory results from AN-106 February 1, 2009 (see Table 2) grab samples indicated the supernatant was below the chemistry limit that applied at the time as identified in HNF-SD-WM-TSR-006, Tank Farms Technical Safety Requirements, Administrative Control (AC) 5.16,more » 'Corrosion Mitigation Controls.' (The limits have since been removed from the Technical Safety Requirements (TSR) and are captured in OSD-T-151-00007, Operating Specifications for the Double-Shell Storage Tanks.) Problem evaluation request WRPS-PER-2009-0218 was submitted February 9, 2009, to document the finding that the supernatant chemistry for grab samples taken from the middle and upper regions of the supernatant was noncompliant with the chemistry control limits. The lab results for the samples taken from the bottom region of the supernatant met AC 5.16 limits.« less
NASA Technical Reports Server (NTRS)
James, John T.
2008-01-01
The toxicological assessments of 2 grab sample canisters (GSCs) from the Shuttle are reported. Formaldehyde badges were not used. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 GSCs averaged 111, 82, and 78%, respectively. The Shuttle atmosphere was acceptable for human respiration.
ERIC Educational Resources Information Center
Pardini, Priscilla
2004-01-01
Experts suggest that moral and ethical lapses are undermining public trust in schools and their leaders--institutions and individuals long held to a higher standard of behavior than their peers in corporate and political arenas. Incidents of financial kickbacks, nepotism and conflicts of interest may grab the news media's attention. Yet…
Reanalysis of Plutonium and Americium-241 in the Tank 19F Closure Grab and Core Samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swingle, R.F.
2003-02-11
Tank 19F is scheduled to be closed by March 2004. To close this tank, a characterization of the waste remaining in the tank was required to confirm the inventory of various species for input into groundwater transport models. This characterization has been developed by a combination of process knowledge, visual observation and sample analysis. The characterization samples were obtained by High Level Waste Division (HLWD) personnel and characterized by SRTC personnel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Serne, R. Jeffrey; Bjornstad, Bruce N.; Gee, Glendon W.
2002-12-15
This report presents vadose sediment characterization data that improves understanding of the nature and extent of past releases in the B tank farm. A vertical borehole, located approximately 15 ft (5 m) from the northeast edge of single-shell tank 241-B-110 was drilled to a total depth of 264.4 ft bgs, the groundwater table was encountered at 255.8 ft bgs. During drilling, a total of 3 two-ft long, 4-inch diameter split-spoon core samples were collected between 10 and 254 ft bgs-an average of every 7.5 ft. Grab samples were collected between these core sample intervals to yield near continuous samples tomore » a depth of 78.3 m (257 ft). Geologic logging occurred after each core segment was emptied into an open plastic container, followed by photographing and sub-sampling for physical and chemical characterization. In addition, 54 out of a total of 120 composite grab samples were opened, sub-sampled, logged, and photographed. Immediately following the geologic examination, the core and selected grab samples were sub-sampled for moisture content, gamma-emission radiocounting, tritium and strontium-90 determinations, total carbon and inorganic carbon content, and 8 M nitric acid extracts (which provide a measure of the total leachable sediment content of contaminants) and one-to-one sediment to water extracts (which provide soil pH, electrical conductivity, cation, and anion data and water soluble contaminant data. Later, additional aliquots of selected sleeves or grab samples were removed to measure particle size distribution and mineralogy and to squeeze porewater. Major conclusions follow. Vadose zone contamination levels were lower than generally anticipated prior to the initiation of the field investigation. Strong evidence of extensive vadose zone lateral migration in WMA BBXBY exists. There are indications that such lateral migration may have extended into WMA B-BX-BY from adjacent past practice discharge sites. Ponding of runoff from natural precipitation in the WMA may have added significant amounts of spatially confined infiltration. Borehole soil characterization has identified strontium-90 and technetium-99 as the two main radionuclides underneath tank B-110. The Sr-90 data indicate limited future mobility unless abnormally high amounts of infiltration occur. Neither technetium-99 nor strontium-90 is expected to significantly impact groundwater in the current moisture and geochemical environment below the B Tank Farm. At borehole 299-E33-46 (near tank B-110), strontium 90 was found down to 26 m (85 ft) bgs with strontium 90 values up to 11,250 pCi/g of sediment. Other tank wastes contaminants (e.g., nitrate) were found down to 69 m (200 ft) bgs. The strontium-90 was immobile under the current ionic regime in the pore water. Technetium-99 releases into the vadose zone near tank B-110 from a transfer line leak appear to be inconsequential. Technetium-99 does not occur above detection limits in the upper parts of the vadose zone where other tank waste constituents (e.g., strontium-90, fluoride, carbonate, and nitrate) are present. Technetium-99 is present in a few soil samples in the PlioPleistocene unit. This unit appears to be an effective conduit for lateral migration and the presence of technetium-99 is postulated to have another source.« less
Sekiguchi, Yusuke; Kato, Tomohisa; Honda, Keita; Kanetaka, Hiroyasu; Izumi, Shin-Ichi
2017-08-01
The effect of the grab bar on dynamic stability when elderly people enter the bathtub remains unclear. The purpose of the present study is to examine the age-related effect of the grab bar on dynamic stability during lateral stepping over an obstacle when entering bathtub. Sixteen young, healthy adults and sixteen elderly adults participated. The subjects performed lateral stepping over an obstacle with and without vertical and horizontal bars. Displacement and velocity of the center of mass and utilized friction, which is the required coefficient of friction to avoid slipping, were simultaneously measured by a three-dimensional motion analysis system and two force plates. A post hoc test for two-way ANOVA revealed that velocity of the center of mass in the vertical direction (p<0.05) and peak-to-peak values of the center of mass in the lateral (p<0.05) and vertical directions (p<0.05) with each grab bar were significantly slower and smaller than those without the grab bar in young and elderly people. Moreover, the utilized friction at push off of the trailing leg with the vertical bar in elderly people was lower (p<0.05) than that in participants without the grab bar. The use of each grab bar while performing a lateral step over an obstacle may help maintaining balance in lateral and vertical directions. However, use of the vertical bar while lateral stepping over an object in elderly people may need low utilized friction to prevent slipping. Copyright © 2017 Elsevier Ltd. All rights reserved.
Lozach, Sophie; Dauvin, Jean-Claude; Méar, Yann; Murat, Anne; Davoult, Dominique; Migné, Aline
2011-12-01
Sampling the sea bottom surface remains difficult because of the surface hydraulic shock due to water flowing through the gear (i.e., the bow wave effect) and the loss of epifauna organisms due to the gear's closing mechanism. Slow-moving mobile epifauna, such as the ophiuroid Ophiothrix fragilis, form high-density patches in the English Channel, not only on pebbles like in the Dover Strait or offshore Brittany but also on gravel in the Bay of Seine (>5000 ind m(-2)). Such populations form high biomasses and control the water transfer from the water column to the sediment. Estimating their real density and biomass is essential for the assessment of benthic ecosystem functioning using trophic web modelling. In this paper, we present and discuss the patch patterns and sampling efficiency of the different methods for collecting in the dense beds of O. fragilis in the Bay of Seine. The large Hamon grab (0.25 m(-2)) highly under-estimated the ophiuroid density, while the Smith McIntyre appeared adequate among the tested sampling grabs. Nowadays, diving sampling, underwater photography and videos with remote operated vehicle appear to be the recommended alternatives to estimate the real density of such dense slow-moving mobile epifauna. Copyright © 2011 Elsevier Ltd. All rights reserved.
Presley, Todd K.; Jamison, Marcael T.J.; Young-Smith, Stacie T. M.
2006-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data were collected at two stations, continuous discharge data at one station, continuous streamflow data at two stations, and water-quality data at five stations, which include the continuous discharge and streamflow stations. This report summarizes rainfall, discharge, streamflow, and water-quality data collected between July 1, 2005 and June 30, 2006. A total of 23 samples was collected over five storms during July 1, 2005 to June 30, 2006. The goal was to collect grab samples nearly simultaneously at all five stations, and flow-weighted time-composite samples at the three stations equipped with automatic samplers; however, all five storms were partially sampled owing to lack of flow at the time of sampling at some sites, or because some samples collected by the automatic sampler did not represent water from the storm. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). Additionally, grab samples were analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/quality-control samples were also collected during storms and during routine maintenance to verify analytical procedures and check the effectiveness of equipment-cleaning procedures.
Impact of sampling techniques on measured stormwater quality data for small streams
Harmel, R.D.; Slade, R.M.; Haney, R.L.
2010-01-01
Science-based sampling methodologies are needed to enhance water quality characterization for setting appropriate water quality standards, developing Total Maximum Daily Loads, and managing nonpoint source pollution. Storm event sampling, which is vital for adequate assessment of water quality in small (wadeable) streams, is typically conducted by manual grab or integrated sampling or with an automated sampler. Although it is typically assumed that samples from a single point adequately represent mean cross-sectional concentrations, especially for dissolved constituents, this assumption of well-mixed conditions has received limited evaluation. Similarly, the impact of temporal (within-storm) concentration variability is rarely considered. Therefore, this study evaluated differences in stormwater quality measured in small streams with several common sampling techniques, which in essence evaluated within-channel and within-storm concentration variability. Constituent concentrations from manual grab samples and from integrated samples were compared for 31 events, then concentrations were also compared for seven events with automated sample collection. Comparison of sampling techniques indicated varying degrees of concentration variability within channel cross sections for both dissolved and particulate constituents, which is contrary to common assumptions of substantial variability in particulate concentrations and of minimal variability in dissolved concentrations. Results also indicated the potential for substantial within-storm (temporal) concentration variability for both dissolved and particulate constituents. Thus, failing to account for potential cross-sectional and temporal concentration variability in stormwater monitoring projects can introduce additional uncertainty in measured water quality data. Copyright ?? 2010 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America. All rights reserved.
40 CFR 60.153 - Monitoring of operations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Plants § 60.153 Monitoring of operations. (a) The owner or operator of any sludge incinerator subject to... device which can be used to determine either the mass or volume of sludge charged to the incinerator. The... access to the sludge charged so that a well-mixed representative grab sample of the sludge can be...
40 CFR 60.153 - Monitoring of operations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Plants § 60.153 Monitoring of operations. (a) The owner or operator of any sludge incinerator subject to... device which can be used to determine either the mass or volume of sludge charged to the incinerator. The... access to the sludge charged so that a well-mixed representative grab sample of the sludge can be...
40 CFR 60.153 - Monitoring of operations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Plants § 60.153 Monitoring of operations. (a) The owner or operator of any sludge incinerator subject to... device which can be used to determine either the mass or volume of sludge charged to the incinerator. The... access to the sludge charged so that a well-mixed representative grab sample of the sludge can be...
40 CFR 60.153 - Monitoring of operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Plants § 60.153 Monitoring of operations. (a) The owner or operator of any sludge incinerator subject to... device which can be used to determine either the mass or volume of sludge charged to the incinerator. The... access to the sludge charged so that a well-mixed representative grab sample of the sludge can be...
Conventional plating methods were used to quantify heterotrophic bacteria from a drinking water distribution system. Three media, plate count agar (PCA), R2A agar and sheep blood agar (TSA-SB) were used to determine heterotrophic plate count (HPC) levels. Grab samples were collec...
Investigation of HIV-1 infected and uninfected cells using the optical trapping technique
NASA Astrophysics Data System (ADS)
Ombinda-Lemboumba, S.; Malabi, R.; Lugongolo, M. Y.; Thobakgale, S. L.; Manoto, S.; Mthunzi-Kufa, P.
2017-02-01
Optical trapping has emerged as an essential tool for manipulating single biological material and performing sophisticated spectroscopy analysis on individual cell. The optical trapping technique has been used to grab and immobilize cells from a tightly focused laser beam emitted through a high numerical aperture objective lens. Coupling optical trapping with other technologies is possible and allows stable sample trapping, while also facilitating molecular, chemical and spectroscopic analysis. For this reason, we are exploring laser trapping combined with laser spectroscopy as a potential non-invasive method of interrogating individual cells with a high degree of specificity in terms of information generated. Thus, for the delivery of as much pathological information as possible, we use a home-build optical trapping and spectroscopy system for real time probing human immunodeficiency virus (HIV-1) infected and uninfected single cells. Briefly, our experimental rig comprises an infrared continuous wave laser at 1064 nm with power output of 1.5 W, a 100X high numerical aperture oil-immersion microscope objective used to capture and immobilise individual cell samples as well as an excitation source. Spectroscopy spectral patterns obtained by the 1064 nm laser beam excitation provide information on HIV-1 infected and uninfected cells. We present these preliminary findings which may be valuable for the development of an HIV-1 point of care detection system.
NASA Technical Reports Server (NTRS)
James, John T.
2007-01-01
The toxicological assessments of 2 grab sample canisters (GSCs) and one pair of formaldehyde badges from the Shuttle are reported. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 GSCs averaged 109, 95, and 97%, respectively. Three formaldehyde controls averaged 93% recovery. The Shuttle atmosphere was acceptable for human respiration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brigmon, R.; Leskinen, S.; Kearns, E.
2011-10-10
Detection of Legionella pneumophila in cooling towers and domestic hot water systems involves concentration by centrifugation or membrane filtration prior to inoculation onto growth media or analysis using techniques such as PCR or immunoassays. The Portable Multi-use Automated Concentration System (PMACS) was designed for concentrating microorganisms from large volumes of water in the field and was assessed for enhancing surveillance of L. pneumophila at the Savannah River Site, SC. PMACS samples (100 L; n = 28) were collected from six towers between August 2010 and April 2011 with grab samples (500 ml; n = 56) being collected before and aftermore » each PMACS sample. All samples were analyzed for the presence of L. pneumophila by direct fluorescence immunoassay (DFA) using FITC-labeled monoclonal antibodies targeting serogroups 1, 2, 4 and 6. QPCR was utilized for detection of Legionella spp. in the same samples. Counts of L. pneumophila from DFA and of Legionella spp. from qPCR were normalized to cells/L tower water. Concentrations were similar between grab and PMACS samples collected throughout the study by DFA analysis (P = 0.4461; repeated measures ANOVA). The same trend was observed with qPCR. However, PMACS concentration proved advantageous over membrane filtration by providing larger volume, more representative samples of the cooling tower environment, which led to reduced variability among sampling events and increasing the probability of detection of low level targets. These data highlight the utility of the PMACS for enhanced surveillance of L. pneumophila by providing improved sampling of the cooling tower environment.« less
NASA Astrophysics Data System (ADS)
Matosziuk, L.; Gallo, A.; Hatten, J. A.; Heckman, K. A.; Nave, L. E.; Sanclements, M.; Strahm, B. D.; Weiglein, T.
2017-12-01
Wildfire can dramatically affect the quantity and quality of soil organic matter (SOM), producing thermally altered organic material such as pyrogenic carbon (PyC) and polyaromatic hydrocarbons (PAHs). The movement of this thermally altered material through terrestrial and aquatic ecosystems can differ from that of unburned SOM, with far-reaching consequences for soil carbon cycling and water quality. Unfortunately, due to the rapid ecological changes following fire and the lack of robust pre-fire controls, the cycling of fire-altered carbon is still poorly understood. In December 2016, the Chimney Tops 2 fire in Great Smoky Mountains National Park burned over co-located terrestrial and aquatic NEON sites. We have leveraged the wealth of pre-fire data at these sites (chemical, physical, and microbial characterization of soils, continuous measurements of both soil and stream samples, and five soil cores up to 110 cm in depth) to conduct a thorough study of the movement of fire-altered organic matter through terrestrial and aquatic ecosystems. Stream samples have been collected weekly beginning 5 weeks post-fire. Grab samples of soil were taken at discrete time points in the first two months after the fire. Eight weeks post-fire, a second set of cores was taken and resin lysimeters installed at three different depths. A third set of cores and grab samples will be taken 8-12 months after the fire. In addition to routine soil characterization techniques, solid samples from cores and grab samples at all time points will be analyzed for PyC and PAHs. To determine the effect of fire on dissolved organic matter (DOM), hot water extracts of these soil samples, as well as the stream samples and lysimeter samples, will also be analyzed for PyC and PAHs. Selected samples will be analyzed by 1D- and 2D-NMR to further characterize the chemical composition of DOM. This extensive investigation of the quantity and quality of fire-altered organic material at discrete time points will provide insight into the production and cycling of thermally-altered SOM and DOM. We hypothesize that PyC will be an important source of SOM to surface mineral soil horizons, and that the quantity of DOM will increase after fire, providing a rapid pulse of C to deep soils and aquatic systems.
Buschini, Annamaria; Giordani, Federica; Pellacani, Claudia; Rossi, Carlo; Poli, Paola
2008-04-01
The level of exposure to hazardous compounds through drinking water is low but it is maintained throughout life, therefore representing a risk factor for human health. The use of techniques averaging the consumer's exposure over time could be more useful than relying on intermittent grab samples that may misrepresent average tap water concentrations due to short-term temporal variability. In this study, we compared the induction of in vitro cytotoxic and genotoxic effects (DNA damage by the comet assay) in relation to different sampling methods, i.e. exposure over time (semipermeable membrane devices, SPMDs, exposed for 30 days) or intermittent grab samples (5 weekly water sampling, C18 concentration). Waters with different chemical characteristics were sampled to test the sensitivity of the two methods. We did not found any positive correlation between the biological findings and water chemical parameters. SPMD extracts induced a significantly greater DNA damage than C18. The different behaviour was specially found for the water samples with a low level of organic compounds and when C18 extracts were highly cytotoxic. Our findings suggest that SPMD could be of a great interest in assessing genotoxic contaminants in both raw and drinking water, with great suitability for continuous monitoring. Furthermore, the results of this study have confirmed the great importance of the biological assays in evaluating the effects of a complex mixture such as water in addition to the conventional chemical examination of water quality.
NASA Technical Reports Server (NTRS)
James, John T.
2001-01-01
The toxicological assessment of air samples returned at the end of the STS-105 (7 A.1) flight to the ISS is reported. ISS air samples were taken in August 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. Preflight and end-of-mission samples were obtained from Discovery using GSCs. Analytical methods have not changed from earlier reports, and surrogate standard recoveries were 64-115%. Pressure tracking indicated no leaks in the canisters.
Lo, Brian K C; Minaker, Leia; Chan, Alicia N T; Hrgetic, Jessica; Mah, Catherine L
2016-03-01
To adapt and validate a survey instrument to assess the nutrition environment of grab-and-go establishments at a university campus. A version of the Nutrition Environment Measures Survey for grab-and-go establishments (NEMS-GG) was adapted from existing NEMS instruments and tested for reliability and validity through a cross-sectional assessment of the grab-and-go establishments at the University of Toronto. Product availability, price, and presence of nutrition information were evaluated. Cohen's kappa coefficient and intra-class correlation coefficients (ICC) were assessed for inter-rater reliability, and construct validity was assessed using the known-groups comparison method (via store scores). Fifteen grab-and-go establishments were assessed. Inter-rater reliability was high with an almost perfect agreement for availability (mean κ = 0.995) and store scores (ICC = 0.999). The tool demonstrated good face and construct validity. About half of the venues carried fruit and vegetables (46.7% and 53.3%, respectively). Regular and healthier entrée items were generally the same price. Healthier grains were cheaper than regular options. Six establishments displayed nutrition information. Establishments operated by the university's Food Services consistently scored the highest across all food premise types for nutrition signage, availability, and cost of healthier options. Health promotion strategies are needed to address availability and variety of healthier grab-and-go options in university settings.
Spatial and temporal variability in benthic invertebrate assemblages in Upper Klamath Lake, Oregon
Stauffer-Olsen, Natalie J.; Carter, James L.; Fend, Steven V.
2017-01-01
Upper Klamath Lake (UKL) in southern Oregon has experienced declines in water quality due to excessive nutrient loading. This has led to annual cyanobacterial blooms, primarily of Aphanizomenon flos-aquae (AFA). Benthic invertebrates are important food resources for benthic feeding fishes; however, they can increase autochthonous nutrient cycling in lakes and as a result might be contributing to poor water quality in UKL. This study determined the density and taxonomic richness of benthic invertebrate assemblages in three geographic regions (north, central, and south) and three habitats (littoral, open-water and trench) across UKL. Sediment composition and water quality were also characterized at each of the 21 benthic invertebrate collection sites. Three sampling trips were made from May–July 2013. Mean lake-wide invertebrate density was 12 617 ± 7506 individuals m-2 (n = 63, based on 189 Ekman grabs) with oligochaetes, chironomids, and leeches representing 97% of all individuals. Mean invertebrate richness per sample was 16 ± 4 (n = 63). Two and three-way repeated measures ANOVAs identified differences in invertebrate densities and richness among regions, habitats, and sampling periods. There were no differences in total density among sampling periods. Total density was higher in littoral compared to open-water habitats, and in the northern region, proximal to all riverine inputs to the lake, compared to the central or southern regions. Although variances were heterogeneous, the number of taxa appeared to differ between habitats and regions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... proposed location and purpose of the activities, including: (1) Gravity and magneto-metric measurements; (2...) Sediment sampling of a limited nature using either core or grab samplers, and the specified diameter and...) Hydrographic and oceanographic measurements, including the setting of instruments; and (7) Small diameter core...
Code of Federal Regulations, 2011 CFR
2011-07-01
... proposed location and purpose of the activities, including: (1) Gravity and magneto-metric measurements; (2...) Sediment sampling of a limited nature using either core or grab samplers, and the specified diameter and...) Hydrographic and oceanographic measurements, including the setting of instruments; and (7) Small diameter core...
1991-05-01
schedule for construction, upgrading or operation of wastewater treatment facilities or any other environmental programs, which may effect storm water quality of...if the storm water quality may be similar. c. Two sets of samples are required to be collected: (1) A grab during the first 30 minutes of the rainfall
NASA Technical Reports Server (NTRS)
James, John T.
2001-01-01
The toxicological assessment of air samples returned at the end of the STS-l04 (7 A) flight to the ISS is reported. ISS air samples were taken in June and July 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. Preflight and end-of-mission samples were obtained from Atlantis using GSCs. Solid sorbent air sampler (SSAS) samples were obtained from the ISS in April, June, and July. Analytical methods have not changed from earlier reports, and all quality control measures were met.
NASA Astrophysics Data System (ADS)
Rufino, Marta M.; Baptista, Paulo; Pereira, Fábio; Gaspar, Miguel B.
2018-01-01
In the current work we propose a new method to sample surface sediment during bivalve fishing surveys. Fishing institutes all around the word carry out regular surveys with the aim of monitoring the stocks of commercial species. These surveys comprise often more than one hundred of sampling stations and cover large geographical areas. Although superficial sediment grain sizes are among the main drivers of benthic communities and provide crucial information for studies on coastal dynamics, overall there is a strong lack of this type of data, possibly, because traditional surface sediment sampling methods use grabs, that require considerable time and effort to be carried out on regular basis or on large areas. In face of these aspects, we developed an easy and un-expensive method to sample superficial sediments, during bivalve fisheries monitoring surveys, without increasing survey time or human resources. The method was successfully evaluated and validated during a typical bivalve survey carried out on the Northwest coast of Portugal, confirming that it had any interference with the survey objectives. Furthermore, the method was validated by collecting samples using a traditional Van Veen grabs (traditional method), which showed a similar grain size composition to the ones collected by the new method, on the same localities. We recommend that the procedure is implemented on regular bivalve fishing surveys, together with an image analysis system to analyse the collected samples. The new method will provide substantial quantity of data on surface sediment in coastal areas, using a non-expensive and efficient manner, with a high potential application in different fields of research.
NASA Astrophysics Data System (ADS)
Krogh, E.; Gill, C.; Bell, R.; Davey, N.; Martinsen, M.; Thompson, A.; Simpson, I. J.; Blake, D. R.
2012-12-01
The release of hydrocarbons into the environment can have significant environmental and economic consequences. The evolution of smaller, more portable mass spectrometers to the field can provide spatially and temporally resolved information for rapid detection, adaptive sampling and decision support. We have deployed a mobile platform membrane introduction mass spectrometer (MIMS) for the in-field simultaneous measurement of volatile and semi-volatile organic compounds. In this work, we report instrument and data handling advances that produce geographically referenced data in real-time and preliminary data where these improvements have been combined with high precision ultra-trace VOCs analysis to adaptively sample air plumes near oil and gas operations in Alberta, Canada. We have modified a commercially available ion-trap mass spectrometer (Griffin ICX 400) with an in-house temperature controlled capillary hollow fibre polydimethylsiloxane (PDMS) polymer membrane interface and in-line permeation tube flow cell for a continuously infused internal standard. The system is powered by 24 VDC for remote operations in a moving vehicle. Software modifications include the ability to run continuous, interlaced tandem mass spectrometry (MS/MS) experiments for multiple contaminants/internal standards. All data are time and location stamped with on-board GPS and meteorological data to facilitate spatial and temporal data mapping. Tandem MS/MS scans were employed to simultaneously monitor ten volatile and semi-volatile analytes, including benzene, toluene, ethylbenzene and xylene (BTEX), reduced sulfur compounds, halogenated organics and naphthalene. Quantification was achieved by calibrating against a continuously infused deuterated internal standard (toluene-d8). Time referenced MS/MS data were correlated with positional data and processed using Labview and Matlab to produce calibrated, geographical Google Earth data-visualizations that enable adaptive sampling protocols. This real-time approach has been employed in a moving vehicle to identify and track downwind plumes of fugitive VOC emissions near hydrocarbon upgrading and chemical processing facilities in Fort Saskatchewan, Alberta. This information was relayed to a trailing vehicle, which collected stationary grab samples in evacuated canisters for ultra trace analysis of over seventy VOC analytes. In addition, stationary time series data were collected and compared with grab samples co-located with our sampling line. Spatially and temporally resolved, time referenced MS/MS data for several air contaminants associated with oil and gas processing were processed in real time to produce geospatial data for visualization in Google Earth. This information was used to strategically locate grab samples for high precision, ultra trace analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Engle, V.D.; Summers, J.K.; Macauley, J.M.
1994-12-31
The Environmental Monitoring and Assessment Program for Estuaries (EMAP-E) in the Gulf of Mexico supplements its base sampling effort each year with localized, intensive spatial sampling in selected large estuarine systems. By selecting random locations within 70 km{sup 2} hexagonal areas, individual estuaries were sampled using EMAP methods but at four times the density as base sampling. In 1992, 19 sites were sampled in Lake Pontchartrain, Louisiana. In 1 993, 18 sites were sampled in Sabine Lake, Texas and 12 sites were sampled in Choctawhatchee Bay, Florida. At all sites, sediment grabs were taken and analyzed for benthic species compositionmore » and abundance, for toxicity to Ampelisca, and for organic and inorganic sediment contaminants. An indicator of biotic integrity, the benthic index, was calculated to represent the status of benthic communities. A series of statistical techniques, such as stepwise regression analysis, were employed to determine whether the variation in the benthic index could be associated with variation in sediment contaminants, sediment toxicity, or levels of dissolved oxygen. Spatial distributions of these parameters were examined to determine the geographical co-occurrence of degraded benthic communities and environmental stressors. In Lake Pontchartrain, for example, 85% of the variation in the benthic index was associated with decreased levels of dissolved oxygen, and increased concentrations of PCBs, alkanes, copper, tin, and zinc in the sediments.« less
Presley, Todd K.; Jamison, Marcael T.J.
2009-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream, and to assess the effects from the H-1 storm drain on Manoa Stream. For this program, rainfall data were collected at three stations, continuous discharge data at five stations, and water-quality data at six stations, which include the five continuous discharge stations. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2008, and June 30, 2009. Within the Halawa Stream drainage area, three storms (October 25 and December 11, 2008, and February 3, 2009) were sampled during July 1, 2008, to June 30, 2009. A total of 43 environmental samples were collected during these three storms. During the storm of October 25, 2009, 31 samples were collected and analyzed individually for metals only. The other 12 samples from the other two storms were analyzed for some or all of the following analytes: total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, and zinc). Additionally, grab samples were analyzed for some or all of the following analytes: oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Some grab and composite samples were analyzed for only a partial list of these analytes, either because samples could not be delivered to the laboratory in a timely manner, or an insufficient volume of sample was collected by the automatic samplers. Two quality-assurance/quality-control samples were collected after cleaning automatic sampler lines to verify that the sampling lines were not contaminated. Four environmental samples were collected at the H-1 Storm Drain during July 1, 2008, to June 30, 2009. An oil and grease sample and a composite sample were collected during the storm on November 15, 2008, and two composite samples were collected during the January 11, 2009, storm. All samples at this site were collected using an automatic sampler. Samples were analyzed for some or all of the following analytes: total suspended solids, nutrients, oil and grease, total petroleum hydrocarbons, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). One qualityassurance/quality-control sample was collected after cleaning automatic sampler lines to verify that the sampling lines were not contaminated. During the storm of January 11, 2009, the two composite samples collected at H-1 Storm Drain were collected about three hours apart. Higher constituent concentrations were detected in the first 2 composite sample relative to the second composite sample, although the average discharge was higher during the period when the second sample was collected.
Soyuz 7 Return Samples: Assessment of Air Quality Aboard the International Space Station
NASA Technical Reports Server (NTRS)
James, John T.
2004-01-01
The toxicological assessments of one grab sample canister (GSC), 6 dual sorbent tubes (DSTs), and 20 formaldehyde badges returned aboard Soyuz 7 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSC were 84-89%. The recoveries of the less volatile surrogates from the DSTs were 87 to 112%; however, 13C-acetone was only recovered at 53-59%. Formaldehyde recoveries from 2 lab controls were 87 and 95%; trip controls were not returned to ground.
Toxicological Assessment of ISS Air Quality: Contingency Sampling - February 2013
NASA Technical Reports Server (NTRS)
Meyers, Valerie
2013-01-01
Two grab sample containers (GSCs) were collected by crew members onboard ISS in response to a vinegar-like odor in the US Lab. On February 5, the first sample was collected approximately 1 hour after the odor was noted by the crew in the forward portion of the Lab. The second sample was collected on February 22 when a similar odor was noted and localized to the end ports of the microgravity science glovebox (MSG). The crewmember removed a glove from the MSG and collected the GSC inside the glovebox volume. Both samples were returned on SpaceX-2 for ground analysis.
ISOLOK VALVE ACCEPTANCE TESTING FOR DWPF SME SAMPLING PROCESS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edwards, T.; Hera, K.; Coleman, C.
2011-12-05
Evaluation of the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) cycle time identified several opportunities to improve the CPC processing time. Of the opportunities, a focus area related to optimizing the equipment and efficiency of the sample turnaround time for DWPF Analytical Laboratory was identified. The Mechanical Systems & Custom Equipment Development (MS&CED) Section of the Savannah River National Laboratory (SRNL) evaluated the possibility of using an Isolok{reg_sign} sampling valve as an alternative to the Hydragard{reg_sign} valve for taking process samples. Previous viability testing was conducted with favorable results using the Isolok sampler and reported in SRNL-STI-2010-00749 (1).more » This task has the potential to improve operability, reduce maintenance time and decrease CPC cycle time. This report summarizes the results from acceptance testing which was requested in Task Technical Request (TTR) HLW-DWPF-TTR-2010-0036 (2) and which was conducted as outlined in Task Technical and Quality Assurance Plan (TTQAP) SRNL-RP-2011-00145 (3). The Isolok to be tested is the same model which was tested, qualified, and installed in the Sludge Receipt Adjustment Tank (SRAT) sample system. RW-0333P QA requirements apply to this task. This task was to qualify the Isolok sampler for use in the DWPF Slurry Mix Evaporator (SME) sampling process. The Hydragard, which is the current baseline sampling method, was used for comparison to the Isolok sampling data. The Isolok sampler is an air powered grab sampler used to 'pull' a sample volume from a process line. The operation of the sampler is shown in Figure 1. The image on the left shows the Isolok's spool extended into the process line and the image on the right shows the sampler retracted and then dispensing the liquid into the sampling container. To determine tank homogeneity, a Coliwasa sampler was used to grab samples at a high and low location within the mixing tank. Data from the two locations were compared to determine if the contents of the tank were well mixed. The Coliwasa sampler is a tube with a stopper at the bottom and is designed to obtain grab samples from specific locations within the drum contents. A position paper (4) was issued to address the prototypic flow loop issues and simulant selections. A statistically designed plan (5) was issued to address the total number of samples each sampler needed to pull, to provide the random order in which samples were pulled and to group samples for elemental analysis. The TTR required that the Isolok sampler perform as well as the Hydragard sampler during these tests to ensure the acceptability of the Isolok sampler for use in the DWPF sampling cells. Procedure No.L9.4-5015 was used to document the sample parameters and process steps. Completed procedures are located in R&D Engineering job folder 23269.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... (TOC) based upon an analysis of any single grab or composite sample. (2) If contaminated runoff is... which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity... (1,000 ppm), the permitting authority may substitute TOC as a parameter in lieu of COD. A TOC...
Code of Federal Regulations, 2010 CFR
2010-07-01
... (TOC) based upon an analysis of any single grab or composite sample. (2) If contaminated runoff is... which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity... (1,000 ppm), the permitting authority may substitute TOC as a parameter in lieu of COD. A TOC...
Code of Federal Regulations, 2010 CFR
2010-07-01
... (TOC) based upon an analysis of any single grab or composite sample. (2) If contaminated runoff is... which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity... (1,000 ppm), the permitting authority may substitute TOC as a parameter in lieu of COD. A TOC...
40 CFR 91.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2013 CFR
2013-07-01
... and water vapor interference, the use of the conditioning column may be deleted. (See §§ 91.317 and 91.320.) (3) A CO instrument will be considered to be essentially free of CO2 and water vapor interference if its response to a mixture of three percent CO2 in N2, which has been bubbled through water at...
40 CFR 91.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and water vapor interference, the use of the conditioning column may be deleted. (See §§ 91.317 and 91.320.) (3) A CO instrument will be considered to be essentially free of CO2 and water vapor interference if its response to a mixture of three percent CO2 in N2, which has been bubbled through water at...
40 CFR 91.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2012 CFR
2012-07-01
... and water vapor interference, the use of the conditioning column may be deleted. (See §§ 91.317 and 91.320.) (3) A CO instrument will be considered to be essentially free of CO2 and water vapor interference if its response to a mixture of three percent CO2 in N2, which has been bubbled through water at...
40 CFR 91.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2014 CFR
2014-07-01
... and water vapor interference, the use of the conditioning column may be deleted. (See §§ 91.317 and 91.320.) (3) A CO instrument will be considered to be essentially free of CO2 and water vapor interference if its response to a mixture of three percent CO2 in N2, which has been bubbled through water at...
40 CFR 91.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and water vapor interference, the use of the conditioning column may be deleted. (See §§ 91.317 and 91.320.) (3) A CO instrument will be considered to be essentially free of CO2 and water vapor interference if its response to a mixture of three percent CO2 in N2, which has been bubbled through water at...
Toxicological Assessment of ISS Air Quality: SpaceX-2 First Ingress
NASA Technical Reports Server (NTRS)
Meyers, Valerie
2013-01-01
One mini-grab sample container (M-GSC) was collected by crew members onboard ISS during first ingress into SpaceX-2 on March 3, 2013, three days after late cargo loading and a pre-launch clean air purge. Recoveries of the three surrogate standards from the m-GSC were: 13C-acetone, 97%; fluorobenzene, 95%; and chlorobenzene, 68%.
Grey water characterization and treatment for reuse in an arid environment.
Smith, E; Bani-Melhem, K
2012-01-01
Grey water from a university facilities building in Cairo, Egypt was analysed for basic wastewater parameters. Mean concentrations were calculated based on grab samples over a 16-month period. Values for chemical oxygen demand (COD) and nutrients exceeded values reported in a number of other studies of grey water, while coliform counts were also high. A submerged membrane bioreactor (SMBR) system using a hollow fibre ultrafiltration membrane was used to treat the grey water with the aim of producing effluent that meets reuse guidelines for agriculture. A test run for 50 days at constant transmembrane pressure resulted in very good removal for key parameters including COD, total suspended solids (TSS), colour, turbidity, ammonia nitrogen, anionic surfactants, and coliform bacteria. High standard deviations were observed for COD and coliform concentrations for both monthly grab samples and influent values from the 50-day SMBR experiment. SMBR effluent meets international and local guidelines for at least restricted irrigation, particularly as pertains to COD, TSS, and faecal coliforms which were reduced to mean treated values of 50 mg/L, 0 mg/L (i.e., not detected), and <50 cfu/100 mL, respectively.
Water-quality data of stormwater runoff from Davenport, Iowa, 1992 and 1994
Schaap, B.D.; Einhellig, R.F.
1996-01-01
During 1992 and 1994, stormwater runoff in Davenport, Iowa, was sampled from the following land use types: agricultural and vacant, residential, commercial, parks and wooded areas, and industrial. Grab samples collected within the first hour of the runoff event were analyzed for many constituents including volatile organic compounds. Flow-weighted composite samples, composed from discrete samples collected at 15-minute intervals during the first three hours of the event or until discharge returned to pre-event levels, also were analyzed for many constituents including major ions, nitrogen, phosphorus, metals, total organic carbon, acid/base-neutral organics, organochlorine pesticides, and polycyclic aromatic hydrocarbons.
Toxicological Assessment of ISS Air Quality: June - September 2013 (Increment 36)
NASA Technical Reports Server (NTRS)
Meyers, Valerie
2014-01-01
Fourteen mini grab sample containers (msGSCs) were collected on ISS between June and September 2013 and were returned on 34S; however, the ATV-4 first ingress mGSC did not contain sufficient sample to report results (initial sample pressure = 1.2 psia). Of the remaining 13 mGSCs, 12 were collected as routine monthly samples in the Russian Service Module (SM), US Laboratory (Lab), and either the Japanese Pressurized Module (JPM) or the Columbus module (Col), and 1 was collected during HTV-4 first ingress. A summary of the analytical results from the 13 valid mGSCs is shown.
NASA Astrophysics Data System (ADS)
Assoumani, Azziz; Margoum, Christelle; Guillemain, Céline; Coquery, Marina
2014-05-01
The monitoring of water bodies regarding organic contaminants, and the determination of reliable estimates of concentrations are challenging issues, in particular for the implementation of the Water Framework Directive. Several strategies can be applied to collect water samples for the determination of their contamination level. Grab sampling is fast, easy, and requires little logistical and analytical needs in case of low frequency sampling campaigns. However, this technique lacks of representativeness for streams with high variations of contaminant concentrations, such as pesticides in rivers located in small agricultural watersheds. Increasing the representativeness of this sampling strategy implies greater logistical needs and higher analytical costs. Average automated sampling is therefore a solution as it allows, in a single analysis, the determination of more accurate and more relevant estimates of concentrations. Two types of automatic samplings can be performed: time-related sampling allows the assessment of average concentrations, whereas flow-dependent sampling leads to average flux concentrations. However, the purchase and the maintenance of automatic samplers are quite expensive. Passive sampling has recently been developed as an alternative to grab or average automated sampling, to obtain at lower cost, more realistic estimates of the average concentrations of contaminants in streams. These devices allow the passive accumulation of contaminants from large volumes of water, resulting in ultratrace level detection and smoothed integrative sampling over periods ranging from days to weeks. They allow the determination of time-weighted average (TWA) concentrations of the dissolved fraction of target contaminants, but they need to be calibrated in controlled conditions prior to field applications. In other words, the kinetics of the uptake of the target contaminants into the sampler must be studied in order to determine the corresponding sampling rate constants (Rs). Each constant links the mass of the a target contaminant accumulated in the sampler to its concentration in water. At the end of the field application, the Rs are used to calculate the TWA concentration of each target contaminant with the final mass of the contaminants accumulated in the sampler. Stir Bar Sorptive Extraction (SBSE) is a solvent free sample preparation technique dedicated to the analysis of moderately hydrophobic to hydrophobic compounds in liquid and gas samples. It is composed of a magnet enclosed in a glass tube coated with a thick film of polydimethysiloxane (PDMS). We recently developed the in situ application of SBSE as a passive sampling technique (herein named "Passive SBSE") for the monitoring of agricultural pesticides. The aim of this study is to perform the calibration of the passive SBSE in the laboratory, and to apply and compare this technique to active sampling strategies for the monitoring of 16 relatively hydrophobic to hydrophobic pesticides in streams, during 2 1-month sampling campaigns. Time-weighted averaged concentrations of the target pesticides obtained from passive SBSE were compared to the target pesticide concentrations of grab samples, and time-related and flow-dependent samples of the streams. Results showed passive SBSE as an efficient alternative to conventional active sampling strategies.
Code of Federal Regulations, 2010 CFR
2010-07-01
... organic carbon (TOC) based upon an analysis of any single grab or composite sample. (2) If contaminated... contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any... substitute TOC as a parameter in lieu of COD. A TOC effluent limitation shall be based on effluent data from...
Code of Federal Regulations, 2010 CFR
2010-07-01
... (TOC) based upon an analysis of any single grab or composite sample. (2) If contaminated runoff is... which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of... the effluent exceeds 1,000 mg/l (1,000 ppm), the permitting authority may substitute TOC as a...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 110 mg/l total organic carbon (TOC) based upon an analysis of any single grab or composite sample. (2... solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type... effluent exceeds 1,000 mg/l (1,000 ppm), the permitting authority may substitute TOC as a parameter in lieu...
King, Brendon; Fanok, Stella; Phillips, Renae; Swaffer, Brooke
2015-01-01
Cryptosporidium continues to be problematic for the water industry, with risk assessments often indicating that treatment barriers may fail under extreme conditions. However, risk analyses have historically used oocyst densities and not considered either oocyst infectivity or species/genotype, which can result in an overestimation of risk if the oocysts are not human infective. We describe an integrated assay for determining oocyst density, infectivity, and genotype from a single-sample concentrate, an important advance that overcomes the need for processing multiple-grab samples or splitting sample concentrates for separate analyses. The assay incorporates an oocyst recovery control and is compatible with standard primary concentration techniques. Oocysts were purified from primary concentrates using immunomagnetic separation prior to processing by an infectivity assay. Plate-based cell culture was used to detect infectious foci, with a monolayer washing protocol developed to allow recovery and enumeration of oocysts. A simple DNA extraction protocol was developed to allow typing of any wells containing infectious Cryptosporidium. Water samples from a variety of source water and wastewater matrices, including a semirural catchment, wastewater, an aquifer recharge site, and storm water, were analyzed using the assay. Results demonstrate that the assay can reliably determine oocyst densities, infectivity, and genotype from single-grab samples for a variety of water matrices and emphasize the varying nature of Cryptosporidium risk extant throughout source waters and wastewaters. This assay should therefore enable a more comprehensive understanding of Cryptosporidium risk for different water sources, assisting in the selection of appropriate risk mitigation measures. PMID:25769833
King, Brendon; Fanok, Stella; Phillips, Renae; Swaffer, Brooke; Monis, Paul
2015-05-15
Cryptosporidium continues to be problematic for the water industry, with risk assessments often indicating that treatment barriers may fail under extreme conditions. However, risk analyses have historically used oocyst densities and not considered either oocyst infectivity or species/genotype, which can result in an overestimation of risk if the oocysts are not human infective. We describe an integrated assay for determining oocyst density, infectivity, and genotype from a single-sample concentrate, an important advance that overcomes the need for processing multiple-grab samples or splitting sample concentrates for separate analyses. The assay incorporates an oocyst recovery control and is compatible with standard primary concentration techniques. Oocysts were purified from primary concentrates using immunomagnetic separation prior to processing by an infectivity assay. Plate-based cell culture was used to detect infectious foci, with a monolayer washing protocol developed to allow recovery and enumeration of oocysts. A simple DNA extraction protocol was developed to allow typing of any wells containing infectious Cryptosporidium. Water samples from a variety of source water and wastewater matrices, including a semirural catchment, wastewater, an aquifer recharge site, and storm water, were analyzed using the assay. Results demonstrate that the assay can reliably determine oocyst densities, infectivity, and genotype from single-grab samples for a variety of water matrices and emphasize the varying nature of Cryptosporidium risk extant throughout source waters and wastewaters. This assay should therefore enable a more comprehensive understanding of Cryptosporidium risk for different water sources, assisting in the selection of appropriate risk mitigation measures. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Survival of rhizobia in two soils as influenced by storage conditions.
Martyniuk, Stefan; Oroń, Jadwiga
2008-01-01
Two soils were kept moist at 4 degrees C, -20 degrees C or air-dried at 20-22 degrees C and after one week, one month, two months and six months of storage at these conditions changes in soil populations of Rhizobium leguminosarum bv. trifolii (Rlt) and Rhizobium leguminosarum bv. viciae (Rlv) were examined. In one air-dried soil (from Grab6w) markedly lower numbers of both Rlt and Rlv., as compared to the refrigerated or frozen samples, were found already after 1 week of storage. In the case of the second soil (from Osiny) air-drying significantly reduced numbers of the rhizobia after 2 and 6 months of storage. The soil from Osiny contained higher amounts of C org, total N and clay than the Grabów soil. Both soils stored moist in a refrigerator (4 degrees C) or frozen (-20 degrees C) retained similar populations of the examined rhizobia throughout the entire storage period, indicating that soil freezing is not detrimental for the examined rhizobia.
Gear and survey efficiency of patent tongs for oyster populations on restoration reefs.
Schulte, David M; Lipcius, Romuald N; Burke, Russell P
2018-01-01
Surveys of restored oyster reefs need to produce accurate population estimates to assess the efficacy of restoration. Due to the complex structure of subtidal oyster reefs, one effective and efficient means to sample is by patent tongs, rather than SCUBA, dredges, or bottom cores. Restored reefs vary in relief and oyster density, either of which could affect survey efficiency. This study is the first to evaluate gear (the first full grab) and survey (which includes selecting a specific half portion of the first grab for further processing) efficiencies of hand-operated patent tongs as a function of reef height and oyster density on subtidal restoration reefs. In the Great Wicomico River, a tributary of lower Chesapeake Bay, restored reefs of high- and low-relief (25-45 cm, and 8-12 cm, respectively) were constructed throughout the river as the first large-scale oyster sanctuary reef restoration effort (sanctuary acreage > 20 ha at one site) in Chesapeake Bay. We designed a metal frame to guide a non-hydraulic mechanical patent tong repeatedly into the same plot on a restored reef until all oysters within the grab area were captured. Full capture was verified by an underwater remotely-operated vehicle. Samples (n = 19) were taken on nine different reefs, including five low- (n = 8) and four high-relief reefs (n = 11), over a two-year period. The gear efficiency of the patent tong was estimated to be 76% (± 5% standard error), whereas survey efficiency increased to 81% (± 10%) due to processing. Neither efficiency differed significantly between young-of-the-year oysters (spat) and adults, high- and low-relief reefs, or years. As this type of patent tong is a common and cost-effective tool to evaluate oyster restoration projects as well as population density on fished habitat, knowing the gear and survey efficiencies allows for accurate and precise population estimates.
Changes in Benthos Associated with Mussel (Mytilus edulis L.) Farms on the West-Coast of Scotland
Wilding, Thomas A.; Nickell, Thomas D.
2013-01-01
Aquaculture, as a means of food production, is growing rapidly in response to an increasing demand for protein and the over-exploitation of wild fisheries. This expansion includes mussels (family Mytilidae) where production currently stands at 1.5 million tonnes per annum. Mussel culture is frequently perceived as having little environmental impact yet mussel biodeposits and shell debris accumulate around the production site and are linked to changes in the benthos. To assess the extent and nature of changes in benthos associated with mussel farming grab and video sampling around seven mussel farms was conducted. Grab samples were analysed for macrofauna and shell-hash content whilst starfish were counted and the shell-hash cover estimated from video imaging. Shell-hash was patchily distributed and occasionally dominated sediments (maximum of 2116 g per 0.1 m2 grab). Mean shell-hash content decreased rapidly at distances >5 m from the line and, over the distance 1–64 m, decreased by three orders of magnitude. The presence of shell-hash and the distance-from-line influenced macrofaunal assemblages but this effect differed between sites. There was no evidence that mussel farming was associated with changes in macrobenthic diversity, species count or feeding strategy. However, total macrofaunal count was estimated to be 2.5 times higher in close proximity to the lines, compared with 64 m distance, and there was evidence that this effect was conditional on the presence of shell-hash. Starfish density varied considerably between sites but, overall, they were approximately 10 times as abundant close to the mussel-lines compared with 64 m distance. There was no evidence that starfish were more abundant in the presence of shell-hash visible on the sediment surface. In terms of farm-scale benthic impacts these data suggest that mussel farming is a relatively benign way of producing food, compared with intensive fish-farming, in similar environments. PMID:23874583
Clow, D.W.; Johncox, D.A.
1995-01-01
Lake sediment and surface water from Standley Lake, Great Western Reservoir, and Mower Reservoir, near Denver, Colorado, were sampled and analyzed for selected radionuclides during August through October, 1992. Sample concentrations were summarized and compared to results from a study conducted in 1983-84. Median plutonium-239,240 (239,240Pu) concentrations in lake-sediment grab samples from Standley Lake, Great Western Reservoir, and Mower Reservoir were 0.037, 0.105, and 0.351 picocuries per gram (pCi/g). The maximum concen- tration of 239,240Pu dissolved in lake water was 0.009 picocuries per liter, substantially below limits suggested by the Colorado Department of Health and the Environment. Dissolved concentrations of gross alpha and uranium isotopes were below National Drinking Water Standards in all water samples. There was no statistically significant difference between 239,240Pu concentration in lake-sediment grab samples collected from Standley Lake in 1983-84 and in 1992; however, there was a small, but statistically significant, difference at Great Western Reservoir (p<0.05). In 1992 at Great Western Reservoir, median 239,240Pu concentrations were 0.040 pCi/g lower than in 1983-84. There was a small, but statistically significant (p<0.05) difference in 239,240Pu concentrations in lake- bottom-sediment cores collected in 1983-84 and in 1992. Measured concentrations tended to be higher in 1983-84 than in 1992. The differences were greatest at concentrations above 1.5 pCi/g; in those samples concentrations were 10 to 30% higher in 1983-84 than in 1992.
NASA Astrophysics Data System (ADS)
Sañé, E.; Chiocci, F. L.; Basso, D.; Martorelli, E.
2016-10-01
The effects of different environmental factors controlling the distribution of different morphologies, sizes and growth forms of rhodoliths in the western Pontine Archipelago have been studied. The analysis of 231 grab samples has been integrated with 68 remotely operated vehicle (ROV) videos (22 h) and a high resolution (<1 m) side scan sonar mosaic of the seafloor surrounding the Archipelago, covering an area of approximately 460 km2. Living rhodoliths were collected in approximately 10% of the grab samples and observed in approximately 30% of the ROV dives. The combination of sediment sampling, video surveys and acoustic facies mapping suggested that the presence of rhodoliths can be associated to the dishomogeneous high backscatter sonar facies and high backscatter facies. Both pralines and unattached branches were found to be the most abundant morphological groups (50% and 41% of samples, respectively), whereas boxwork rhodoliths were less common, accounting only for less than 10% of the total number of samples. Pralines and boxwork rhodoliths were almost equally distributed among large (28%), medium (36%) and small sizes (36%). Pralines generally presented a fruticose growth form (49% of pralines) even if pralines with encrusting-warty (36% of pralines) or lumpy (15% of pralines) growth forms were also present. Morphologies, sizes and growth forms vary mainly along the depth gradient. Large rhodoliths with a boxwork morphology are abundant at depth, whereas unattached branches and, in general, rhodoliths with a high protuberance degree are abundant in shallow waters. The exposure to storm waves and bottom currents related to geostrofic circulation could explain the absence of rhodoliths off the eastern side of the three islands forming the Archipelago.
Then Came the Fire: Personal Accounts From the Pentagon, 11 September 2001
2011-01-01
office to let folks there know what had happened. Maj. Lorie A. Brown was the Chief Nurse of the DiLorenzo Clinic at the Pentagon. She was... nurse , three medics—grab vests, grab radios, grab this. “Go, you’re going to three and four. Call me when you get there and let me know what you...volunteers coming in—”I’m a doc,” “I’m a nurse ,” “I’m here to help. What can I do?” “Okay, here’s a vest, here’s a bag. You’re going to”—you know
Code of Federal Regulations, 2010 CFR
2010-07-01
... mg/l total organic carbon (TOC) based upon an analysis of any single grab or composite sample. (2) If... contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any... substitute TOC as a parameter in lieu of COD. A TOC effluent limitation shall be based on effluent data from...
NASA Technical Reports Server (NTRS)
James. John T.
2010-01-01
The toxicological assessments of 2 grab sample canisters (GSCs) from the Shuttle are reported. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (13C-acetone, fluorobenzene, and chlorobenzene) from the 2 Shuttle GSCs averaged 93, 85%, and 88%, respectively. Based on the end-of-mission sample, the Shuttle atmosphere was acceptable for human respiration. The toxicological assessment of 7 GSCs from the ISS is also shown. The recoveries of the 3 standards (as listed above) from the GSCs averaged 78, 96 and 90%, respectively. Recovery from formaldehyde control badges ranged from 90 to 112%.
Girardoz, S; Tomov, R; Eschen, R; Quicke, D L J; Kenis, M
2007-10-01
The horse-chestnut leaf miner, Cameraria ohridella, is an invasive alien species defoliating horse-chestnut, a popular ornamental tree in Europe. This paper presents quantitative data on mortality factors affecting larvae and pupae of the leaf miner in Switzerland and Bulgaria, both in urban and forest environments. Two sampling methods were used and compared: a cohort method, consisting of the surveying of pre-selected mines throughout their development, and a grab sampling method, consisting of single sets of leaves collected and dissected at regular intervals. The total mortality per generation varied between 14 and 99%. Mortality was caused by a variety of factors, including parasitism, host feeding, predation by birds and arthropods, plant defence reaction, leaf senescence, intra-specific competition and inter-specific competition with a fungal disease. Significant interactions were found between mortality factors and sampling methods, countries, environments and generation. No mortality factor was dominant throughout the sites, generations and methods tested. Plant defence reactions constituted the main mortality factor for the first two larval stages, whereas predation by birds and arthropods and parasitism were more important in older larvae and pupae. Mortality caused by leaf senescence was often the dominant mortality factor in the last annual generation. The cohort method detected higher mortality rates than the grab sampling method. In particular, mortality by plant defence reaction and leaf senescence were better assessed using the cohort method, which is, therefore, recommended for life table studies on leaf miners.
Chen, Wei; Pan, Suhong; Cheng, Hao; Sweetman, Andrew J; Zhang, Hao; Jones, Kevin C
2018-06-15
A passive water sampler based on the diffusive gradients in thin-films (DGT) technique was developed and tested for 3 groups of endocrine disrupting chemicals (EDCs, including oestrogens, alkyl-phenols and bisphenols). Three different resins (hydrophilic-lipophilic-balanced (HLB), XAD18 and Strata-XL-A (SXLA)) were investigated for their suitability as the binding phase for DGT devices. Laboratory tests across a range of pH (3.5-9.5), ionic strength (0.001-0.5 M) and dissolved organic matter concentration (0-20 mg L -1 ) showed HLB and XAD18-DGT devices were more stable compared to SXLA-DGT. HLB-DGT and XAD18-DGT accumulated test chemicals with time consistent with theoretical predictions, while SXLA-DGT accumulated reduced amounts of chemical. DGT performance was also compared in field deployments up to 28 days, alongside conventional active sampling at a wastewater treatment plant. Uptake was linear to the samplers over 18 days, and then began to plateau/decline, indicating the maximum deployment time in those conditions. Concentrations provided by the DGT samplers compared well with those provided by auto-samplers. DGT integrated concentrations over the deployment period in a way that grab-sampling cannot. The advantages of the DGT sampler over active sampling include: low cost, ease of simultaneous multi-site deployment, in situ analyte pre-concentration and reduction of matrix interferences compared with conventional methods. Compared to other passive sampler designs, DGT uptake is independent of flow rate and therefore allows direct derivation of field concentrations from measured compound diffusion coefficients. This passive DGT sampler therefore constitutes a viable and attractive alternative to conventional grab and active water sampling for routine monitoring of selected EDCs. Copyright © 2018 Elsevier Ltd. All rights reserved.
Ensminger, Michael P; Vasquez, Martice; Tsai, Hsing-Ju; Mohammed, Sarah; Van Scoy, A; Goodell, Korena; Cho, Gail; Goh, Kean S
2017-10-01
Monitoring of surface waters for organic contaminants is costly. Grab water sampling often results in non-detects for organic contaminants due to missing a pulse event or analytical instrumentation limitations with a small sample size. Continuous Low-Level Aquatic Monitoring (CLAM) samplers (C.I.Agent ® Solutions) continually extract and concentrate organic contaminants in surface water onto a solid phase extraction disk. Utilizing CLAM samplers, we developed a broad spectrum analytical screen for monitoring organic contaminants in urban runoff. An intermediate polarity solid phase, hydrophobic/lipophilic balance (HLB), was chosen as the sorbent for the CLAM to target a broad range of compounds. Eighteen urban-use pesticides and pesticide degradates were targeted for analysis by LC/MS/MS, with recoveries between 59 and 135% in laboratory studies. In field studies, CLAM samplers were deployed at discrete time points from February 2015 to March 2016. Half of the targeted chemicals were detected with reporting limits up to 90 times lower than routine 1-L grab samples with good precision between field replicates. In a final deployment, CLAM samplers were compared to 1-L water samples. In this side-by-side comparison, imidacloprid, fipronil, and three fipronil degradates were detected by the CLAM sampler but only imidacloprid and fipronil sulfone were detected in the water samples. However, concentrations of fipronil sulfone and imidacloprid were significantly lower with the CLAM and a transient spike of diuron was not detected. Although the CLAM sampler has limitations, it can be a powerful tool for development of more focused and informed monitoring efforts based on pre-identified targets in the field. Copyright © 2017 Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-10-01
... fabrics shall comply with the requirements of Federal Specification CCC-C-426 for Type I, Class 3 material... not less than 0.008 inch in thickness meeting the requirements of Federal Specification L-P-375 for Type I or II, Class 1, film. (f) Grab straps. The grab straps shall be of materials permitted for the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berkley, R.E.; Gardner, B.D.; Holland, J.F.
1997-12-31
A high-speed gas chromatograph coupled with a high-speed time-of-flight mass spectrometer was used to gain a six-fold increase in overall rate of analytical throughput for analysis of EPA Method TO-14 target compounds. Duration of chromatograms was 180 seconds. One hundred mass spectra per second, ranging from 35 to 270 mass units, were collected. Single ion chromatograms were searched at appropriate retention times for chromatographic peaks, which were integrated. Thirty-eight of the forty-one TO-14 target compounds were calibrated using standards at five concentrations from 2.5 to 40 ppb. Four grab samples of ambient air were collected at four different locations atmore » an automobile repair facility, and two grab samples were collected less than one minute apart at a site near a chemical plant, just before and just after passage of three large diesel trucks. All samples were analyzed on the same day they were collected. Most of the duplicate analyses were in close agreement. Ability of the high-speed TOF/GC/MS system to perform analyses of TO-14 target compounds rapidly and precisely was demonstrated. This paper has been reviewed according to US Environmental Protection Agency peer and administrative review policies and approved for presentation and publication. Mention of trade names or commercial products does not constitute endorsement or recommendation for use.« less
GRAbB: Selective Assembly of Genomic Regions, a New Niche for Genomic Research
Zhang, Hao; van Diepeningen, Anne D.; van der Lee, Theo A. J.; Waalwijk, Cees; de Hoog, G. Sybren
2016-01-01
GRAbB (Genomic Region Assembly by Baiting) is a new program that is dedicated to assemble specific genomic regions from NGS data. This approach is especially useful when dealing with multi copy regions, such as mitochondrial genome and the rDNA repeat region, parts of the genome that are often neglected or poorly assembled, although they contain interesting information from phylogenetic or epidemiologic perspectives, but also single copy regions can be assembled. The program is capable of targeting multiple regions within a single run. Furthermore, GRAbB can be used to extract specific loci from NGS data, based on homology, like sequences that are used for barcoding. To make the assembly specific, a known part of the region, such as the sequence of a PCR amplicon or a homologous sequence from a related species must be specified. By assembling only the region of interest, the assembly process is computationally much less demanding and may lead to assemblies of better quality. In this study the different applications and functionalities of the program are demonstrated such as: exhaustive assembly (rDNA region and mitochondrial genome), extracting homologous regions or genes (IGS, RPB1, RPB2 and TEF1a), as well as extracting multiple regions within a single run. The program is also compared with MITObim, which is meant for the exhaustive assembly of a single target based on a similar query sequence. GRAbB is shown to be more efficient than MITObim in terms of speed, memory and disk usage. The other functionalities (handling multiple targets simultaneously and extracting homologous regions) of the new program are not matched by other programs. The program is available with explanatory documentation at https://github.com/b-brankovics/grabb. GRAbB has been tested on Ubuntu (12.04 and 14.04), Fedora (23), CentOS (7.1.1503) and Mac OS X (10.7). Furthermore, GRAbB is available as a docker repository: brankovics/grabb (https://hub.docker.com/r/brankovics/grabb/). PMID:27308864
GRAbB: Selective Assembly of Genomic Regions, a New Niche for Genomic Research.
Brankovics, Balázs; Zhang, Hao; van Diepeningen, Anne D; van der Lee, Theo A J; Waalwijk, Cees; de Hoog, G Sybren
2016-06-01
GRAbB (Genomic Region Assembly by Baiting) is a new program that is dedicated to assemble specific genomic regions from NGS data. This approach is especially useful when dealing with multi copy regions, such as mitochondrial genome and the rDNA repeat region, parts of the genome that are often neglected or poorly assembled, although they contain interesting information from phylogenetic or epidemiologic perspectives, but also single copy regions can be assembled. The program is capable of targeting multiple regions within a single run. Furthermore, GRAbB can be used to extract specific loci from NGS data, based on homology, like sequences that are used for barcoding. To make the assembly specific, a known part of the region, such as the sequence of a PCR amplicon or a homologous sequence from a related species must be specified. By assembling only the region of interest, the assembly process is computationally much less demanding and may lead to assemblies of better quality. In this study the different applications and functionalities of the program are demonstrated such as: exhaustive assembly (rDNA region and mitochondrial genome), extracting homologous regions or genes (IGS, RPB1, RPB2 and TEF1a), as well as extracting multiple regions within a single run. The program is also compared with MITObim, which is meant for the exhaustive assembly of a single target based on a similar query sequence. GRAbB is shown to be more efficient than MITObim in terms of speed, memory and disk usage. The other functionalities (handling multiple targets simultaneously and extracting homologous regions) of the new program are not matched by other programs. The program is available with explanatory documentation at https://github.com/b-brankovics/grabb. GRAbB has been tested on Ubuntu (12.04 and 14.04), Fedora (23), CentOS (7.1.1503) and Mac OS X (10.7). Furthermore, GRAbB is available as a docker repository: brankovics/grabb (https://hub.docker.com/r/brankovics/grabb/).
NASA Technical Reports Server (NTRS)
James, John T.
2010-01-01
Reports on the air quality aboard the Space Shuttle (STS-129), and the International Space station (ULF3). NASA analyzed the grab sample canisters (GSCs) and the formaldehyde badges aboard both locations for carbon monoxide levels. The three surrogates: (sup 13)C-acetone, fluorobenzene, and chlorobenzene registered 109, 101, and 109% in the space shuttle and 81, 87, and 55% in the International Space Station (ISS). From these results the atmosphere in both the Space Shuttle and the International Space Station (ISS) was found to be breathable.
1988-12-01
a flue gas grab sample for orsat analysis (measures oxygen, and carbon dioxide for stack gas molecular weight determination and emissions correction... molecular weight, was obtained during particulate sampling. Testing was initially started on boiler 2 at the maximum rated steam output of 120,000 lbs/hr...I, r*~td AN[D l FL B( R\\ ViQ( lPjN L!II(,t 1 (d) Open burning of put.rcible iear- i\\ % ~i~ emisions , ec.dirig c dn jc p. c ,f1 pre- cri :rig pair
46 CFR 160.076-21 - Component materials.
Code of Federal Regulations, 2010 CFR
2010-10-01
... by § 160.076-25(d)(2)(iii). (c) The average grab breaking strength and tear strength of the inflation....076-25(d)(2)(ii), must be at least 90% of the grab breaking strength and tear strength determined from... breaking strength or tear strength may be more than 20% below the results obtained in approval testing. (d...
46 CFR 160.049-4 - Construction and workmanship.
Code of Federal Regulations, 2010 CFR
2010-10-01
... or less in each layer, cemented together with an all-purpose vinyl adhesive such as or equivalent to U.S. Rubber No. M-6256 or Minnesota Mining No. EC-870 and No. EC-1070; (ii) Three layers or less that may be cemented; and (iii) Staggered butts and seams of adjacent layers. (d) Grab Straps. Grab...
The role of fear and expectancies in capture of covert attention by spiders.
Devue, Christel; Belopolsky, Artem V; Theeuwes, Jan
2011-08-01
Fear-related stimuli are often prioritized during visual selection but it remains unclear whether capture by salient objects is more likely to occur when individuals fear those objects. In this study, participants with high and low fear of spiders searched for a circle while on some trials a completely irrelevant fear-related (spider) or neutral distractor (butterfly/leaf) was presented simultaneously in the display. Our results show that when you fear spiders and you are not sure whether a spider is going to be present, then any salient distractor (i.e., a butterfly) grabs your attention, suggesting that mere expectation of a spider triggered compulsory monitoring of all irrelevant stimuli. However, neutral stimuli did not grab attention when high spider fearful people knew that a spider could not be present during a block of trials, treating the neutral stimuli just as the low spider fearful people do. Our results show that people that fear spiders inspect potential spider-containing locations in a compulsory fashion even though directing attention to this location is completely irrelevant for the task. Reduction of capture can only be accomplished when people that fear spiders do not expect a spider to be present. 2011 APA, all rights reserved
Kobayashi, Eiji; Kakuda, Mamoru; Tanaka, Yusuke; Morimoto, Akiko; Egawa-Takata, Tomomi; Matsuzaki, Shinya; Ueda, Yutaka; Yoshino, Kiyoshi; Kimura, Tadashi
2016-01-01
The study aims to prevent serious urologic injury during a radical hysterectomy; we propose that one of the most important procedural steps is the careful management of the vesicouterine ligament (VUL). Between January 2013 and October 2014, we used a novel internal retractor in 17 patients undergoing a laparoscopic radical hysterectomy (LRH) for early-stage cervical cancer to obtain and secure a better surgical view. For management of the VUL during the laparoscopic procedure, we routinely used an internal retractor (EndoGrab; Virtual Ports, Misgav, Israel) and vessel tape to reposition the ureter in a safe lateral-caudal direction. Using an EndoGrab, we were easily able to reproduce a suitable surgical view that simulated the one obtained by an abdominal route for radical hysterectomy. Using this improved laparoscopic procedure, we completed radical hysterectomies in all 17 cases without a ureteral injury complication. Our modified method using an EndoGrab is effective for the prevention of ureteral injury during a LRH, and its ease of use makes it suitable even for those surgeons early in their laparoscopic learning curve. © 2016 S. Karger AG, Basel.
NASA Technical Reports Server (NTRS)
James, John T.
2013-01-01
A summary of the analytical results from 6 grab sample containers (GSCs) and 12 pairs of formaldehyde badges collected on ISS and returned aboard 29S or 31 S is shown in an accompanying table. The average recoveries of the 3 surrogate standards from the GSCs were as follows: C-l3-acetone, 128%; fluorobenzene, 114%; and chlorobenzene, 78%. Recoveries of two lab-control formaldehyde badges averaged 95%.
Revised Toxicological Assessment of ISS Air Quality: May 2012 - August 2012
NASA Technical Reports Server (NTRS)
Meyers, Valerie
2012-01-01
A summary of the analytical results from 12 grab sample containers (GSCs) collected on ISS and returned aboard 30S is shown in Table 1. The average recoveries of the 3 surrogate standards from the GSCs were as follows: 12C-acetone, 115 +/-- 11%; fluorobenzene, 108 +/- 8%; and chlorobenzene, 102 +/- 16%. Shaded rows indicate data that re limited due to low sample pressures. For completeness, previously reported data from the US Lab collected in May 2012 are included here as well. The revised report provides results from one returned sample that was unlabeled and originally assumed to be unused. The sample was prepared and analyzed for the purpose of measuring the surrogate compounds. It was later determined, based on serial number, that this was the HTB3 first ingress sample.
Blake, Christine E.; Wethington, Elaine; Farrell, Tracy J.; Bisogni, Carole A.; Devine, Carol M.
2012-01-01
Employed parents’ work and family conditions provide behavioral contexts for their food choices. Relationships between employed parents’ food-choice coping strategies, behavioral contexts, and dietary quality were evaluated. Data on work and family conditions, sociodemographic characteristics, eating behavior, and dietary intake from two 24-hour dietary recalls were collected in a random sample cross-sectional pilot telephone survey in the fall of 2006. Black, white, and Latino employed mothers (n=25) and fathers (n=25) were recruited from a low/moderate income urban area in upstate New York. Hierarchical cluster analysis (Ward’s method) identified three clusters of parents differing in use of food-choice coping strategies (ie, Individualized Eating, Missing Meals, and Home Cooking). Cluster sociodemographic, work, and family characteristics were compared using χ2 and Fisher’s exact tests. Cluster differences in dietary quality (Healthy Eating Index 2005) were analyzed using analysis of variance. Clusters differed significantly (P≤0.05) on food-choice coping strategies, dietary quality, and behavioral contexts (ie, work schedule, marital status, partner’s employment, and number of children). Individualized Eating and Missing Meals clusters were characterized by nonstandard work hours, having a working partner, single parenthood and with family meals away from home, grabbing quick food instead of a meal, using convenience entrées at home, and missing meals or individualized eating. The Home Cooking cluster included considerably more married fathers with nonemployed spouses and more home-cooked family meals. Food-choice coping strategies affecting dietary quality reflect parents’ work and family conditions. Nutritional guidance and family policy needs to consider these important behavioral contexts for family nutrition and health. PMID:21338739
Blake, Christine E; Wethington, Elaine; Farrell, Tracy J; Bisogni, Carole A; Devine, Carol M
2011-03-01
Employed parents' work and family conditions provide behavioral contexts for their food choices. Relationships between employed parents' food-choice coping strategies, behavioral contexts, and dietary quality were evaluated. Data on work and family conditions, sociodemographic characteristics, eating behavior, and dietary intake from two 24-hour dietary recalls were collected in a random sample cross-sectional pilot telephone survey in the fall of 2006. Black, white, and Latino employed mothers (n=25) and fathers (n=25) were recruited from a low/moderate income urban area in upstate New York. Hierarchical cluster analysis (Ward's method) identified three clusters of parents differing in use of food-choice coping strategies (ie, Individualized Eating, Missing Meals, and Home Cooking). Cluster sociodemographic, work, and family characteristics were compared using χ(2) and Fisher's exact tests. Cluster differences in dietary quality (Healthy Eating Index 2005) were analyzed using analysis of variance. Clusters differed significantly (P≤0.05) on food-choice coping strategies, dietary quality, and behavioral contexts (ie, work schedule, marital status, partner's employment, and number of children). Individualized Eating and Missing Meals clusters were characterized by nonstandard work hours, having a working partner, single parenthood and with family meals away from home, grabbing quick food instead of a meal, using convenience entrées at home, and missing meals or individualized eating. The Home Cooking cluster included considerably more married fathers with nonemployed spouses and more home-cooked family meals. Food-choice coping strategies affecting dietary quality reflect parents' work and family conditions. Nutritional guidance and family policy needs to consider these important behavioral contexts for family nutrition and health. Copyright © 2011 American Dietetic Association. Published by Elsevier Inc. All rights reserved.
Meyer, Wibke; Reich, Margrit; Beier, Silvio; Behrendt, Joachim; Gulyas, Holger; Otterpohl, Ralf
2016-08-01
This study evaluated the impact of secondary municipal effluent discharge on carbamazepine, diclofenac, and metoprolol concentrations in small and medium rivers in northern Germany and compared the measured environmental concentrations (MECs) to the predicted environmental concentrations (PECs) calculated with four well-established models. During a 1-year sampling period, secondary effluent grab samples were collected at four wastewater treatment plants (WWTPs) together with grab samples from the receiving waters upstream and downstream from the wastewater discharge points. The carbamazepine, diclofenac, and metoprolol concentrations were analyzed with high-performance liquid chromatography-tandem mass spectrometry (HPLC/MS-MS) after solid phase extraction. In the secondary effluents, 84-790 ng/L carbamazepine, 395-2100 ng/L diclofenac, and 745-5000 ng/L metoprolol were detected. The carbamazepine, diclofenac, and metoprolol concentrations analyzed in the rivers downstream from the secondary effluent discharge sites ranged from <5 to 68, 370, and 520 ng/L, respectively. Most of the downstream pharmaceutical concentrations were markedly higher than the corresponding upstream concentrations. The impact of wastewater discharge on the MECs in rivers downstream from the WWTPs was clearly demonstrated, but the correlations of the MECs with dilution factors were poor. The smallest rivers exhibited the largest maximum MECs and the widest ranges of MECs downstream from the wastewater discharge point. Three of the four tested models were conservative, as they showed higher PECs than the MECs in the rivers downstream from the WWTPs. However, the most detailed model underestimated the diclofenac concentrations.
Shallow Water Habitat Mapping in Cape Cod National Seashore: A Post-Hurricane Sandy Study
NASA Astrophysics Data System (ADS)
Borrelli, M.; Smith, T.; Legare, B.; Mittermayr, A.
2017-12-01
Hurricane Sandy had a dramatic impact along coastal areas in proximity to landfall in late October 2012, and those impacts have been well-documented in terrestrial coastal settings. However, due to the lack of data on submerged marine habitats, similar subtidal impact studies have been limited. This study, one of four contemporaneous studies commissioned by the US National Park Service, developed maps of submerged shallow water marine habitats in and around Cape Cod National Seashore, Massachusetts. All four studies used similar methods of data collection, processing and analysis for the production of habitat maps. One of the motivations for the larger study conducted in the four coastal parks was to provide park managers with a baseline inventory of submerged marine habitats, against which to measure change after future storm events and other natural and anthropogenic phenomena. In this study data from a phase-measuring sidescan sonar, bottom grab samples, seismic reflection profiling, and sediment coring were all used to develop submerged marine habitat maps using the Coastal and Marine Ecological Classification Standard (CMECS). Vessel-based acoustic surveys (n = 76) were conducted in extreme shallow water across four embayments from 2014-2016. Sidescan sonar imagery covering 83.37 km2 was collected, and within that area, 49.53 km2 of co-located bathymetric data were collected with a mean depth of 4.00 m. Bottom grab samples (n = 476) to sample macroinvertebrates and sediments (along with other water column and habitat data) were collected, and these data were used along with the geophysical and coring data to develop final habitat maps using the CMECS framework.
Final Report of Tank 241-C-105 Dissolution, the Phase 2 Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meznarich, Huei K.; bolling, Stacey D.; Cooke, Gary A.
2016-10-01
Three clamshell grab samples were taken from Tank 241-C-105 in October 2015 in accordance with RPP-PLAN-60011. Analytical results of those samples were issued in the report RPP-RPT-59115 by Wastren Advantage, Inc., Hanford Laboratory. Solid phase characterization results were reported separately in LAB-RPT-15-00011 and in RPP-RPT-59147. The major solid phases reported to be present were dawsonite [NaAlCO 3(OH) 2], trona [Na 3(HCO 3)(CO 3)·2H 2O], cejkaite [Na 4(UO 2)(CO 3) 3], and an unidentified organic solid, with minor amounts of gibbsite [Al(OH) 3], natrophosphate [Na 7F(PO 4) 2·19H 2O], and traces of unidentified iron-rich and manganese-rich phases. Note that the presencemore » of dawsonite, trona, and cejkaite requires a relatively low pH, likely around pH 9 to 10. One aliquot of each grab sample was provided to 222-S Laboratory Process Chemistry for dissolution studies. Phase 1 of the dissolution testing followed the approved test plan, WRPS-1404813, Rev. 3, and examined the behavior of the Tank 241-C-105 solids treated with water, 19M sodium hydroxide, 2M nitric acid, and 0.5M oxalic acid/2M nitric acid. Phase 2 of the testing was conducted in accordance with instructions from the client and emphasized treatment with 19M sodium hydroxide followed by water washing. This is the report of the Phase 2 testing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeRosier, R.; Waterland, L.R.
1987-03-01
The report gives emission results from field tests of a wood-waste-fired industrial firetube boiler. Emission measurements included: continuous monitoring of flue gas emissions: source assessment sampling system (SASS) sampling of the flue-gas with subsequent laboratory analysis of samples to give total flue gas organics in two boiling point ranges, compound category information within these ranges, specific quantitation of the semivolatile organic priority pollutants, and flue gas concentrations of 65 trace elements; Method 5 sampling for particulates; controlled condensation system (CSS) sampling for SO/sub 2/ and SO/sub 3/; and grab sampling of boiler bottom ash for trace element content determinations. Totalmore » organic emissions from the boiler were 5.7 mg/dscm, about 90% of which consisted of volatile compounds.« less
Wastewater Characterization Survey, Holloman Air Force Base, New Mexico
1992-01-01
0.5 ɘ.5 ICompositel Grab J 21 Figure B-3 Sewage Treament Plant (STP#): STP #1 STP #2 STP #3 STP #4 The sampler was located below GN913006 GN913007...65.2 352 Benzene ug/L 0.1163.1 . 23] 27 I Compositel Grab 22 Figure B-4 Sewage Treament Plant (STP#): STP #5 STP #6 STP #7 The sampler was located
Wood, Susanna A; Holland, Patrick T; MacKenzie, Lincoln
2011-02-01
Sampling and monitoring for cyanotoxins can be problematic as concentrations change with environmental and hydrological conditions. Current sampling practices (e.g. grab samples) provide data on cyanotoxins present only at one point in time and may miss areas or times of highest risk. Recent research has identified the widespread distribution of anatoxin-producing benthic cyanobacteria in rivers highlighting the need for development of effective sampling techniques. In this study we evaluated the potential of an in situ method known as solid phase adsorption toxin tracking (SPATT) for collecting and concentrating anatoxin-a (ATX) and homoanatoxin-a (HTX) in river water. Fifteen different adsorption substrates were screened for efficiency of ATX uptake, nine of which retained high proportions (>70%) of ATX. Four substrates were then selected for a 24-h trial in a SPATT bag format in the laboratory. The greatest decrease in ATX in the water was observed with powdered activated carbon (PAC) and Strata-X (a polymeric resin) SPATT bags. A 3-d field study in a river containing toxic benthic cyanobacterial mats was undertaken using PAC and Strata-X SPATT bags. ATX and HTX were detected in all SPATT bags. Surface grab samples were taken throughout the field study and ATX and HTX were only detected in one of the water samples, highlighting the limitations of this currently used method. Both Strata-X and PAC were found to be effective absorbent substrates. PAC has the advantage that it is cheap and readily available and appears to continue to sorb toxins over longer periods than Strata-X. SPATT has the potential to be integrated into current cyanobacterial monitoring programmes and would be a very useful and economical tool for early warning of ATX and HTX contamination in water. Copyright © 2010 Elsevier Ltd. All rights reserved.
Hoard, C.J.; Holtschlag, D.J.; Duris, J.W.; James, D.A.; Obenauer, D.J.
2012-01-01
In 2009, the Michigan Department of Environmental Quality and the U.S. Geological Survey developed a plan to compare the effect of various streamgaging and water-quality collection techniques on streamflow and stream water-quality data for the Saginaw River, Michigan. The Saginaw River is the primary contributor of surface runoff to Saginaw Bay, Lake Huron, draining approximately 70 percent of the Saginaw Bay watershed. The U.S. Environmental Protection Agency has listed the Saginaw Bay system as an "Area of Concern" due to many factors, including excessive sediment and nutrient concentrations in the water. Current efforts to estimate loading of sediment and nutrients to Saginaw Bay utilize water-quality samples collected using a surface-grab technique and flow data that are uncertain during specific conditions. Comparisons of current flow and water-quality sampling techniques to alternative techniques were assessed between April 2009 and September 2009 at two locations in the Saginaw River. Streamflow estimated using acoustic Doppler current profiling technology was compared to a traditional stage-discharge technique. Complex conditions resulting from the influence of Saginaw Bay on the Saginaw River were able to be captured using the acoustic technology, while the traditional stage-discharge technique failed to quantify these effects. Water-quality samples were collected at two locations and on eight different dates, utilizing both surface-grab and depth-integrating multiple-vertical techniques. Sixteen paired samples were collected and analyzed for suspended sediment, turbidity, total phosphorus, total nitrogen, orthophosphate, nitrite, nitrate, and ammonia. Results indicate that concentrations of constituents associated with suspended material, such as suspended sediment, turbidity, and total phosphorus, are underestimated when samples are collected using the surface-grab technique. The median magnitude of the relative percent difference in concentration based on sampling technique was 37 percent for suspended sediment, 26 percent for turbidity, and 9.7 percent for total phosphorus samples collected at both. Acoustic techniques were also used to assist in the determination of the effectiveness of using acoustic-backscatter information for estimating the suspended-sediment concentration of the river water. Backscatter data was collected by use of an acoustic Doppler current profiler, and a Van Dorn manual sampler was simultaneously used to collect discrete water samples at 10 depths (3.5, 7.5, 11, 14, 15.5, 17.5, 19.5, 20.5, 22, and 24.5 ft below the water surface) along two vertical profiles near the center of the Saginaw River near Bay City. The Van Dorn samples were analyzed for suspended-sediment concentrations, and these data were then used to develop a relationship between acoustic-backscatter data. Acoustic-backscatter data was strongly correlated to sediment concentrations and, by using a linear regression, was able to explain 89 percent of the variability. Although this regression technique showed promise for using acoustic backscatter to estimate suspended-sediment concentration, attempts to compare suspended-sediment concentrations to the acoustic signal-to-noise ratio estimates, recorded at the fixed acoustic streamflow-gaging station near Bay City (04157061), resulted in a poor correlation.
Data on subsurface storage of liquid waste near Pensacola, Florida, 1963-1980
Hull, R.W.; Martin, J.B.
1982-01-01
Since 1963, when industrial waste was first injected into the subsurface in northwest Florida, considerable data have been collected relating to the geochemistry of subsurface waste storage. This report presents hydrogeologic data on two subsurface waste storage. This report presents hydrogeologic data on two subsurface storage systems near Pensacola, Fla., which inject liquid industrial waste through deep wells into a saline aquifer. Injection sites are described giving a history of well construction, injection, and testing; geologic data from cores and grab samples; hydrographs of injection rates, volume, pressure, and water levels; and chemical and physical data from water-quality samples collected from injection and monitor wells. (USGS)
Eocene and miocene rocks off the northeastern coast of the United States
Gibson, T.G.
1965-01-01
A grab sample from a depth of 1675 m at a point south of Cape Cod contains early Eocene planktonic Foraminifera and is correlated with the Globorotalia rex zone of Trinidad. The assemblage indicates a depth comparable to that existing today. Regional relations suggest that the Cretaceous and Eocene deposits deepen to the west toward New Jersey. Two mollusk-bearing blocks dredged from the northern side of Georges Bank are correlative with the Miocene Yorktown Formation. Rocks from two other stations are probably Miocene. Benthonic Foraminifera in one sample indicate deposition in cool temperate waters of less than 60 m depth. ?? 1965.
Yim, Sehyuk; Gultepe, Evin; Gracias, David H; Sitti, Metin
2014-02-01
This paper proposes a new wireless biopsy method where a magnetically actuated untethered soft capsule endoscope carries and releases a large number of thermo-sensitive, untethered microgrippers (μ-grippers) at a desired location inside the stomach and retrieves them after they self-fold and grab tissue samples. We describe the working principles and analytical models for the μ-gripper release and retrieval mechanisms, and evaluate the proposed biopsy method in ex vivo experiments. This hierarchical approach combining the advanced navigation skills of centimeter-scaled untethered magnetic capsule endoscopes with highly parallel, autonomous, submillimeter scale tissue sampling μ-grippers offers a multifunctional strategy for gastrointestinal capsule biopsy.
1977-01-01
composed of grab samplers, pump systems and in situ electronic probes -- must be based on a clear understanding of data ne i-,strategy of implementation...be used in situ to determine distributions of various properties in water bodies o interest. Reliabilities of some of these for water quality...programs in that it gives investigators the ability to adjust field sampling procedures and formats to fit given situations. Results from in situ probes can
Potential Use of Passive Sampling for Environmental Monitoring of Petroleum E&P Operations
Traditional environmental monitoring relies on water or soil samples being taken at various time increments and sent to offsite laboratories for analysis. Reliance on grab samples generally captures limited “snapshots” of environmental contaminant concentrations, is time intensive, costly, and generates residual waste from excess sample and/or reagents used in the analysis procedures. As an alternative, we are evaluating swellable organosilica sorbents to create passive sampling systems for monitoring applications. Previous work has focused on absorption and detection of fuels, chlorinated solvents, endocrine disruptors, explosives, pesticides, fluorinated chemicals, and metals including Ba, Sr, Hg, Pb, Fe, Cu, and Zn. The advantages of swellable organosilica are that the material cancapture target compounds for an extended periods of time, does not absorb natural organic matter, and resists biofilm formation since the sorbent possesses an animated surface morphology.
Distribution and habitat of Nitellopsis obtuse (Characeae) in the Laurentian Great Lakes
Schloesser, Donald W.; Hudson, Patrick L.; Nichols, S. Jerrine
1986-01-01
Nitellopsis obtuse, a macroalga (Characeae) native to Europe and Asia, was found in U.S. waters of the St. Clair-Detroit River system in 1983, thus extending the range of this taxon into the Laurentian Great Lakes about 850 km from the St. Lawrence River where it was first discovered in North America in 1978. Its occurrence only in water frequented by commercial shipping vessels suggests that it is distributed via this mechanism. In the St. Clair-Detroit River system, N. obtuse was collected with a Ponar grab at four locations, and with a grapnel at one additional location. It was the ninth most frequently found macrophyte and it was most abundant at Belle Isle in the Detroit River, where the mean dry-weight biomass in Ponar samples was 0 g m-2 in June, 37 g m-2 in August, and 32 g m-2 in September. Maximum biomass of this taxon in one Ponar grab at this location was 289 g m-2 in September. The alga occurred primarily in water of relatively low current velocity (11.3 cm s-1) and in association with Vallisneria americana, Myriophyllum spicatum, Potamogeton richardsonii, Najas flexilis, and Elodea canadensis.
Who Expressed What Emotion? Men Grab Anger, Women Grab Happiness
Neel, Rebecca; Becker, D. Vaughn; Neuberg, Steven L.; Kenrick, Douglas T.
2011-01-01
When anger or happiness flashes on a face in the crowd, do we misperceive that emotion as belonging to someone else? Two studies found that misperception of apparent emotional expressions – “illusory conjunctions” – depended on the gender of the target: male faces tended to “grab” anger from neighboring faces, and female faces tended to grab happiness. Importantly, the evidence did not suggest that this effect was due to the general tendency to misperceive male or female faces as angry or happy, but instead indicated a more subtle interaction of expectations and early visual processes. This suggests a novel aspect of affordance-management in human perception, whereby cues to threat, when they appear, are attributed to those with the greatest capability of doing harm, whereas cues to friendship are attributed to those with the greatest likelihood of providing affiliation opportunities. PMID:22368303
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeRosier, R.; Waterland, L.R.
1987-03-01
The report gives emission results from field tests of a wood-waste-fired industrial firetube boiler. Emission measurements included: continuous monitoring of flue-gas emissions; source assessment sampling system (SASS) sampling of the flue gas with subsequent laboratory analysis of samples to give total flue-gas organics in two boiling-point ranges, compound category information within these ranges, specific quantitation of the semivolatile organic priority pollutants, and flue-gas concentrations of 65 trace elements; Method 5 sampling for particulates; controlled condensation system (CSS) sampling for SO/sub 2/ and SO/sub 3/; and grab sampling of boiler bottom ash for trace-element-content determinations. Emission levels of five polycyclic organicmore » matter species and phenol were quantitated: except for naphthalene, all were emitted at less than 0.4 microgram/dscm.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, S.P.; Hedgecock, N.S.
1989-10-01
Personnel from the AFOEHL conducted a waste-water characterization and hazardous-waste technical assistance survey at MAFB from 28 Nov to 9 Dec 1988. The scope of this survey was to characterize the waste-water, address hazardous-waste-management practices, and explore opportunities for hazardous waste minimization. The waste water survey team analyzed the base's industrial effluent, effluent from oil/water separators, and storm water. The team performed a shop-by-shop evaluation of chemical-waste-management practices. Survey results showed that MAFB needs to improve its hazardous-waste-management program. Recommendations for improvement include: (1) Collecting two additional grab samples on separate days from the hospital discharge. Analyze for EPA Methodmore » 601 to determine if the grab sample from the survey gives a true indication of what is being discharged. (2) Locate the source and prevent mercury from the hospital from discharging into the sanitary sewer. (3) Dilute the soaps used for cleaning at the Fuels Lab, Building 7060. (4) Investigate the source of chromium from the Photo Lab. (5) Clean out the sewer system manhole directly downgradient from the Photo Lab. (6) Locate the source of contamination in the West Ditch Outfall. (7) Reconnect the two oil/water separators that discharge into the storm sewerage system. (8) Investigate the source of methylene chloride coming on the base. (9) Investigate the source of mercury at Fuel Cell Repair, building 7005.« less
Pereira, Anna Carolina Toledo da Cunha; de Siqueira, Tatiane Ribeiro; de Oliveira Prado, Andressa Anunciação; da Silva, Camila Almeida Veiga; de Fátima Silva Moraes, Thaís; Aleixo, Alan Alex; de Magalhaes, José Carlos; de Souza, Gabriel Augusto Pires; Drumond, Betânia Paiva; Ferreira, Gustavo Portela; de Mello Silva, Breno; de Brito Magalhães, Cintia Lopes; Santos, Luciana Lara; Ferreira, Jaqueline Maria Siqueira; Malaquias, Luiz Cosme Cotta; Coelho, Luiz Felipe Leomil
2018-06-01
Dengue is the most prevalent arthropod-borne viral illness in humans worldwide. Single-nucleotide polymorphisms (SNPs) in genes involved in the immune response, such as dendritic cell-specific intercellular adhesion molecule-3-grabbing non-integrin (DC-SIGN), IgG Fc receptor II-A (FcγRIIa), vitamin D receptor (VDR), and tumor necrosis factor alpha (TNF-α), were previously reported to be associated with susceptibility to dengue disease in different human populations. Therefore, due to the relevant association of host immune and genetic status with disease susceptibility/severity of dengue, this work aims to verify the frequency of anti-dengue virus antibodies and some dengue-associated risk SNPs in a population in Minas Gerais State, Southeast Brazil. A total of 1560 individuals were genotyped for polymorphisms in DC-SIGN (rs4804803), FcγRIIa (rs1801274), VDR (rs7975232), and TNF-α (rs1800629). The presence of anti-dengue antibodies (IgM and/or IgG) in these samples was also assayed. Anti-dengue antibodies were detected at an overall frequency of 16.86%, indicating a virus infection in asymptomatic individuals. The genotypic frequencies of all SNPs studied did not differ between the asymptomatic and control groups. Regarding the allelic frequencies of the four SNPs analyzed, a higher frequency was detected of the G allele of FcγRIIa/rs1801274 in the asymptomatic individuals when compared to that in the control group (p = 0.03). Therefore, the results showed a high prevalence of asymptomatic individuals in Minas Gerais State, with a potential association between the presence of the G allele of FcγRIIa/rs1801274 and protection against symptomatic disease.
Gulati, Shelly; Stubblefield, Ashley A; Hanlon, Jeremy S; Spier, Chelsea L; Stringfellow, William T
2014-03-01
Measuring the discharge of diffuse pollution from agricultural watersheds presents unique challenges. Flows in agricultural watersheds, particularly in Mediterranean climates, can be predominately irrigation runoff and exhibit large diurnal fluctuation in both volume and concentration. Flow and pollutant concentrations in these smaller watersheds dominated by human activity do not conform to a normal distribution and it is not clear if parametric methods are appropriate or accurate for load calculations. The objective of this study was to compare the accuracy of five load estimation methods to calculate pollutant loads from agricultural watersheds. Calculation of loads using results from discrete (grab) samples was compared with the true-load computed using in situ continuous monitoring measurements. A new method is introduced that uses a non-parametric measure of central tendency (the median) to calculate loads (median-load). The median-load method was compared to more commonly used parametric estimation methods which rely on using the mean as a measure of central tendency (mean-load and daily-load), a method that utilizes the total flow volume (volume-load), and a method that uses measure of flow at the time of sampling (instantaneous-load). Using measurements from ten watersheds in the San Joaquin Valley of California, the average percent error compared to the true-load for total dissolved solids (TDS) was 7.3% for the median-load, 6.9% for the mean-load, 6.9% for the volume-load, 16.9% for the instantaneous-load, and 18.7% for the daily-load methods of calculation. The results of this study show that parametric methods are surprisingly accurate, even for data that have starkly non-normal distributions and are highly skewed. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
James, John T.
2007-01-01
The toxicological assessments of 2 grab sample canisters (GSCs) and one pair of formaldehyde badges from the Shuttle are reported. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 GSCs averaged 120, 117, and 122 %, respectively. Three formaldehyde controls averaged 98% recovery. The Shuttle atmosphere was acceptable for human respiration. The toxicological assessment of 8 GSCs and 6 pairs of formaldehyde badges from the ISS is shown. The recoveries of the 3 standards (as listed above) from the GSCs averaged 99, 99 and 99%, respectively. Three formaldehyde control badges averaged 98% recovery. Based on these limited samples, the ISS atmosphere is acceptable for human respiration. The alcohol levels were well controlled throughout the period of sampling.
Soyuz 22 Return Samples: Assessment of Air Quality Aboard the International Space Station
NASA Technical Reports Server (NTRS)
Jams, John T.
2010-01-01
Three mini-grab sample containers (m-GSCs) were returned aboard Soyuz 22 because of concerns that new air pollutants were present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The toxicological assessment of 3 m-GSCs from the ISS is shown in Table 1. The recoveries of the 3 standards (as listed above) from the GSCs averaged 103, 95 and 76%, respectively. Recovery from formaldehyde control badges were 90 and 91%.
Yim, Sehyuk; Gultepe, Evin; Gracias, David H.
2014-01-01
This paper proposes a new wireless biopsy method where a magnetically actuated untethered soft capsule endoscope carries and releases a large number of thermo-sensitive, untethered microgrippers (μ-grippers) at a desired location inside the stomach and retrieves them after they self-fold and grab tissue samples. We describe the working principles and analytical models for the μ-gripper release and retrieval mechanisms, and evaluate the proposed biopsy method in ex vivo experiments. This hierarchical approach combining the advanced navigation skills of centimeter-scaled untethered magnetic capsule endoscopes with highly parallel, autonomous, submillimeter scale tissue sampling μ-grippers offers a multifunctional strategy for gastrointestinal capsule biopsy. PMID:24108454
Quantifying Microplastic Pollution in the Mohawk River, Eastern New York State
NASA Astrophysics Data System (ADS)
Smith, J. A.; Hodge, J.; Kurtz, B. G.; Garver, J. I.
2016-12-01
We are investigating the extent to which microplastic particles are reaching the Mohawk River in upstate New York. Microplastics are commonly defined as plastic particles less than 5 mm in diameter, whether deliberately manufactured to be that size or resulting from the fragmentation or erosion of larger pieces of plastic. Despite recent legislative bans, many personal care products such as facial scrubs still use tiny particles of plastic as abrasives. Plastic fibers also make up part of the microplastic load potentially reaching waterways. Microplastic particles are a health hazard for aquatic organisms and an undesirable component of public water supplies. The Mohawk River is the main tributary of the Hudson River, coinciding with the Erie Canal for stretches downriver from Rome, NY, and serves as both the outfall for wastewater treatment plants and the water supply for several municipalities. In some cities along the Mohawk River (e.g., Utica, NY), combined sewer overflows (CSOs) deliver untreated sewage and stormwater directly to the river during heavy rainfall events, increasing the likelihood of microplastic pollution. We used a manta trawl deployed from a rigid inflatable boat to collect 60 samples of planktonic material along the 112-mile section of the Mohawk River and/or Erie Canal between Rome, NY, and the Crescent Dam in Cohoes, NY. Each trawl lasted for 1 mile. We used an Ekman grab sampler to collect 64 samples of channel sediment along the same section of the Mohawk River and/or Erie Canal. Sample processing for planktonic samples includes sieving and wet peroxide oxidation to remove organic material. Sample processing for sediment grab samples includes drying, sieving, density separation, and wet peroxide oxidation. Anthropogenic particles that contain dye are easiest to spot under a microscope. Laboratory analyses indicate that the majority of the planktonic samples include dyed particles in addition to colorless particles likely to be plastic, and that the greatest abundance of suspected microplastic particles was collected in the natural channel of the Mohawk River downstream of the Utica CSO during a heavy rainfall event. We are using Raman spectroscopy to provide definitive identification of plastics and other anthropogenic materials, including paint.
Phase II test plan for the evaluation of the performance of container filling systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
BOGER, R.M.
The PHMC will provide tank wastes for final treatment by BNFL from Hanford's waste tanks. Concerns about the ability for ''grab'' sampling to provide large volumes of representative waste samples has led to the development of a nested, fixed-depth sampling system. Preferred concepts for filling sample containers that meet RCRA organic sample criteria were identified by a PHMC Decision Board. These systems will replace the needle based sampling ''T'' that is currently on the sampling system. This test plan document identifies cold tests with simulants that will demonstrate the preferred bottle filling concepts abilities to provide representative waste samples andmore » will meet RCRA criteria. Additional tests are identified that evaluate the potential for cross-contamination between samples and the ability for the system to decontaminate surfaces which have contacted tank wastes. These tests will be performed with kaolid/water and sand/water slurry simulants in the test rig that was used by AEAT to complete Phase 1 tests in FY 1999.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rich, S.R.
1987-02-01
The report gives results of preliminary performance evaluations and economic analyses of the Advanced Energy Dynamics (AED) electrostatic dry coal-cleaning process. Grab samples of coal-feed-product coals were obtained from 25 operating physical coal-cleaning (PCC) plants. These samples were analyzed for ash, sulfur, and energy content and splits of the original samples of feed run-of-mine coal were provided for bench-scale testing in an electrostatic separation apparatus. The process showed superior sulfur-removal performance at equivalent cost and energy-recovery levels. The ash-removal capability of the process was not evaluated completely: overall, ash-removal results indicated that the process did not perform as well asmore » the PCC plants.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reynolds, D.A.
1997-04-04
New data on tank 241-C-106 were obtained from grab sampling and from compatibility testing of tank C-106 and tank AY-102 wastes. All chemistry-associated and other compatibility Information compiled in this report strongly suggests that the sluicing of the contents of tank C-106, in accord with appropriate controls, will pose no unacceptable risk to workers, public safety, or the environment. In addition, it is expected that the sluicing operation will successfully resolve the High-Heat Safety Issue for tank C-106.
Abu Hena, M K; Kohinoor, S M S; Siddique, M A M; Ismail, J; Idris, M H; Amin, S M N
2012-07-01
Macrobenthos in coastal environment that play a significant role in the food web. It could also use as a good indicator of aquatic ecosystem health. The abundance and composition of macrobenthos in Bakkhali channel system, Cox's Bazar were conducted in relation to the soil parameters. Samples were collected using Ekman Berge bottom grab from five different stations of Bakkhali channel. Macrobenthos were comprised of five major groups namely Polychaeta (9.96-30.31%), Oligochaeta (3.68-59.707%), Crustacea (0.02-58.40%), Bivalvia (1.40-82.09%) and Gastropoda (0.08-4.25%). Total number of macrobenthos was higher at station I (9000 individuals m(-2)) and station II (8517 individuals m(-2)) compared to other stations. Shannon diversity index among the stations ranged from 0.65-1.04. Soil pH and soil moisture ranged from 6.1-6.4 and 23.44-31.29%, respectively. The highest organic carbon concentration was observed at station I (2.11%) and lowest at station III (1.40%). Maximum fraction of sand by weight was found at stations II (81.88%) and III (87.88) while the highest fraction of clay (21.52%) and silt (8.0%) were recorded in station I. It was observed that benthic bivalves were positively correlated (r = 0.891, p > 0.05) with silt fraction of the sediments.
Channel Bottom Morphology in the Deltaic Reach of the Song Hau (mekong) River Channel in Vietnam
NASA Astrophysics Data System (ADS)
Allison, M. A.; Weathers, H. D., III; Meselhe, E. A.
2016-02-01
Boat-based, channel bathymetry and bankline elevation studies were conducted in the tidal and estuarine Mekong River channel using multibeam bathymetry and LIDAR corrected for elevation by RTK satellite positioning. Two mapping campaigns, one at high discharge in October 2014 and one at low discharge in March 2015, were conducted in the lower 100 km reach of the Song Hau distributary channel to (1) examine bottom morphology and its relationship to sediment transport, and (2) to provide information to setup the grid for a multi-dimensional and reduced complexity models of channel hydrodynamics and sediment dynamics. Sand fields were identified in multibeam data by the presence of dunes that were as large as 2-4 m high and 40-80 m wavelength and by clean sands in bottom grabs. Extensive areas of sand at the head and toe of mid-channel islands displayed 10-25 m diameter circular pits that could be correlated with bucket dredge, sand mining activities observed at some of the sites. Large areas of the channel floor were relict (containing little or no modern sediment) in the high discharge campaign, identifiable by the presence of along channel erosional furrows and terraced outcrops along the channel floor and margins. Laterally extensive flat areas were also observed in the channel thalweg. Both these and the relict areas were sampled by bottom grab as stiff silty clays. Complex cross-channel combinations of these morphologies were observed in some transects, suggesting strong bottom steering of tidal and riverine currents. Relative to high discharge, transects above and below the salt penetration limit showed evidence of shallowing in the thalweg and adjacent sloping areas at low discharge in March 2015. This shallowing, combined with the reduced extent of sand fields and furrowed areas, and soft muds in grabs, suggests seasonal trapping of fine grained sediment is occurring by estuarine and tidal circulation.
NASA Astrophysics Data System (ADS)
Johnston, N. A. C.; Bundy, B. A.; Andrew, J. P.; Grimm, B. K.; Ketcherside, D.; Rivero-Zevallos, J. A.; Uhlorn, R. P.
2017-12-01
Lewiston, Idaho is a small city in the Snake River Valley bordering North-Central Idaho and Southeastern Washington, with a population of over 40,000 including the surrounding areas. One of the main industries and employers in the region is a kraft paper mill in North Lewiston, which results in odorous levels of sulfur air pollutants there. The Idaho Department of Environmental Quality has an air monitoring station in Lewiston but measures only air particulate matter (PM). Surprisingly, not much long-term data exists on this area for specific air constituents such as volatile organics, hazardous air pollutants, and sulfur compounds. One year-long study conducted in 2006-2007 by the Nez Perce Tribe found high formaldehyde levels in the area, and warranted further study in July of 2016-2017. Our ongoing study began in the fall of 2016 and investigates the seasonal air composition in the Lewiston area. Specifically, active air sampling via sorbent tubes and analysis by thermal desorption gas chromatography-mass spectrometry (TD-GC-MS). was utilized to measure over 50 volatile organic compounds, hazardous air pollutants, and sulfurous compounds in ambient air (adapted from EPA Method TO-17). Seasonal, diurnal, and spatial variations in air composition were explored with weekly to monthly grab sampling. Dimethyl sulfide (DMS) and dimethyl disulfide (DMDS) were the primary sulfur compounds detected, and these varied considerably depending on time of day, season, location and meteorology. DMS was more prevalent in the summer months, while DMDS was more prevalent in the spring. Elevated concentrations of benzene and chloroform were found in the region during 2017, with average values of short term grab samples over three times the acceptable ambient concentrations in Idaho. These levels did not persist during longer term sampling of 12-hours, however further monitoring is needed to assess a potential health concern.
de Waal-Andrews, Wendy; Gregg, Aiden P; Lammers, Joris
2015-09-01
What type of behaviour affords status, agentic, or communal? Research to date has yielded inconsistent answers. In particular, the conflict view holds that agentic behaviour permits the imperious to grab status through overt force, whereas the functional view holds that communal behaviour permits the talented to earn status through popular appeal. Here, we synthesize both views by taking into account the moderating role played by group hierarchy. Group hierarchy can range from being dominance based (where status is grabbed) to prestige based (where status is granted). In a field study (Study 1), and a laboratory experiment (Study 2), we demonstrate that in different groups, status can be achieved in different ways. Specifically, agentic behaviour promotes status regardless of hierarchy type, whereas the effect of communal behaviour on status is moderated by hierarchy type: it augments it in more prestige-based hierarchies but diminishes it in more dominance-based hierarchies. © 2014 The British Psychological Society.
Effect of Bathroom Aids and Age on Balance Control During Bathing Transfers.
King, Emily C; Novak, Alison C
Bathroom assistive devices are used to improve safety during bathing transfers, but biomechanical evidence to support clinical recommendations is lacking. This study evaluated the effectiveness of common bathroom aids in promoting balance control during bathing transfers. Twenty-six healthy adults (12 young, 14 older) stepped into and out of a slippery bathtub while using a vertical grab bar on the side wall, a horizontal grab bar on the back wall, a bath mat, a side wall touch, or no assistance. Balance control was characterized using center of pressure measures and showed greater instability for older adults. The vertical grab bar and wall touch resulted in the safest (best controlled) transfers. The bath mat provided improved balance control in the axis parallel to the bathtub rim but was equivalent to no assistance perpendicular to the rim, in the direction of obstacle crossing. These results can support clinical recommendations for safe bathing transfers. Copyright © 2017 by the American Occupational Therapy Association, Inc.
Wintertime Methane and Non-Methane Hydrocarbon Measurements Utah's Uintah Basin
NASA Astrophysics Data System (ADS)
Martin, R. S.
2012-12-01
As a part of the winter 2011/2012 Uintah Basin Winter Ozone Study, ambient methane (CH4) and total non-methane hydrocarbons (TNMHC) were measured at a population center (Roosevelt) and within the oil/gas field (Horse Pool). At Horse Pool, near real-time CH4/TNMHC were monitored using a GC-FID analyzer. Samples were collected for 30 seconds once every five minutes. The TNMHC concentrations were reported in ppb-C3, or parts per billion in C3 (propane) equivalents. At Roosevelt, discrete volatile organic carbon (VOC) samples were collected for two weeks beginning on Feb. 14, 2012 using evacuated stainless steel Summa canisters. The samples were collected over four 1-hr time periods spaced throughout the day. After collection, the canisters were shipped to a commercial laboratory for GC-MS quantification. Methane samples were obtained at Roosevelt by whole vial collection and subsequently analyzed via GC-FID. Nominally, the CH4 vials were collected at the start and end of each canister collection period, as well as intermittently throughout the daily periods. Furthermore, CH4 grab samples were collected at several other locations throughout the Basin when possible. For the full wintertime study period (Jan. 19 - Mar. 15, 2012), the CH4 and TNMHC at Horse Pool averaged 3.47±1.8 ppm and 243±253 ppb-C3 (± 1σ), respectively. A very strong diurnal behavior was seen for both classes of compounds, with CH4 maximums approaching 30 ppm in the early morning hours. During the comparative February time period, CH4 concentrations at Horse Pool averaged 3.25±0.07 ppm (± 95% CI), while CH4 at Roosevelt averaged 2.52±0.08 ppm. No strong diurnal behavior was observed at Roosevelt and the maximum CH4 levels only reached 4.08 ppm. Grab samples from the other locations found similar or slightly lower CH4 concentrations, with the exception of Ouray (3.91±1.27 ppm) which was also located in the production/exploration area, but was among the lowest elevation of the sampling sites. It was also observed at Horse Pool that the relationship between CH4 and TNMHC showed a strong function of wind direction. When the winds were out of the northwest the ratio of TNMHC to CH4 was about 185, whereas when the wind was from any other sector the ratio decreased to around 80. Tedlar bag grab samples collected from arrayed locations surrounding Horse Pool verified the wind sector-dependent ratio function, indicating two separate regional source signatures. Examination of well-type locations suggested that these differing regimes may be due to the spatial delineation between predominantly oil or gas wells. Direct comparison of TNMHC between Roosevelt and Horse Pool was not possible because the commercial analysis was unable to identify VOCS with fewer than three carbons and parallel investigators (J. Gillman; NOAA-CSD) observed that these were significant at Horse Pool. Recalling that the averaged TNMHC at Horse Pool was 243 ppb-C3, it should be noted that of the compounds identified at Roosevelt only four (propane, isobutene, n-butane, and n-pentane) were observed at concentrations greater than 1.0 ppb. These species are often associated with urban or traffic areas, as opposed to oil and gas fields. Additionally, examination of the relationships between other typical urban VOCs (BTEX), their ratios also suggest sources associated with urban, traffic dominated plumes.
NASA Technical Reports Server (NTRS)
James, John T.
2001-01-01
The toxicological assessment of air samples returned at the end of the STS-102 (5A.1) flight to the ISS is reported. ISS air samples were taken in late February 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges . A "first-entry" sample of the multipurpose logistics module (MPLM) atmosphere was taken with a GSC, and preflight and end-of-mission samples were obtained from Discovery using GSCs. Analytical methods have not changed from earlier reports, and all quality control measures were met for the data presented herein. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 contribution). Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols were also assessed in each sample. Formaldehyde is quantified separately.
Evaluation of passive samplers for the collection of dissolved organic matter in streams.
Warner, Daniel L; Oviedo-Vargas, Diana; Royer, Todd V
2015-01-01
Traditional sampling methods for dissolved organic matter (DOM) in streams limit opportunities for long-term studies due to time and cost constraints. Passive DOM samplers were constructed following a design proposed previously which utilizes diethylaminoethyl (DEAE) cellulose as a sampling medium, and they were deployed throughout a temperate stream network in Indiana. Two deployments of the passive samplers were conducted, during which grab samples were frequently collected for comparison. Differences in DOM quality between sites and sampling methods were assessed using several common optical analyses. The analyses revealed significant differences in optical properties between sampling methods, with the passive samplers preferentially collecting terrestrial, humic-like DOM. We assert that the differences in DOM composition from each sampling method were caused by preferential binding of complex humic compounds to the DEAE cellulose in the passive samplers. Nonetheless, the passive samplers may provide a cost-effective, integrated sample of DOM in situations where the bulk DOM pool is composed mainly of terrestrial, humic-like compounds.
Breault, Robert F.; Cooke, Matthew G.; Merrill, Michael
2004-01-01
The U.S. Geological Survey, in cooperation with the Massachusetts Executive Office of Environmental Affairs Department of Fish and Game Riverways Program, and the U.S. Environmental Protection Agency, studied sediment and water quality in the lower Neponset River, which is a tributary to Boston Harbor. Grab and core samples of sediment were tested for elements and organic compounds including polyaromatic hydrocarbons, organochlorine pesticides, and polychlorinated biphenyls. Physical properties of sediment samples, including grain size, were also measured. Selected sediment-core samples were tested for reactive sulfides and metals by means of the toxicity characteristic leaching procedure, which are sediment-disposal-related tests. Water quality, with respect to polychlorinated biphenyl contamination, was determined by testing samples collected by PISCES passive-water-column samplers for polychlorinated biphenyl congeners. Total concentrations of polychlorinated biphenyls were calculated by congener and by Aroclor.
Influence of soil moisture on soil respiration
NASA Astrophysics Data System (ADS)
Fer, Miroslav; Kodesova, Radka; Nikodem, Antonin; Klement, Ales; Jelenova, Klara
2015-04-01
The aim of this work was to describe an impact of soil moisture on soil respiration. Study was performed on soil samples from morphologically diverse study site in loess region of Southern Moravia, Czech Republic. The original soil type is Haplic Chernozem, which was due to erosion changed into Regosol (steep parts) and Colluvial soil (base slope and the tributary valley). Soil samples were collected from topsoils at 5 points of the selected elevation transect and also from the parent material (loess). Grab soil samples, undisturbed soil samples (small - 100 cm3, and large - 713 cm3) and undisturbed soil blocks were taken. Basic soil properties were determined on grab soil samples. Small undisturbed soil samples were used to determine the soil water retention curves and the hydraulic conductivity functions using the multiple outflow tests in Tempe cells and a numerical inversion with HYDRUS 1-D. During experiments performed in greenhouse dry large undisturbed soil samples were wetted from below using a kaolin tank and cumulative water inflow due to capillary rise was measured. Simultaneously net CO2 exchange rate and net H2O exchange rate were measured using LCi-SD portable photosynthesis system with Soil Respiration Chamber. Numerical inversion of the measured cumulative capillary rise data using the HYDRUS-1D program was applied to modify selected soil hydraulic parameters for particular conditions and to simulate actual soil water distribution within each soil column in selected times. Undisturbed soil blocks were used to prepare thin soil sections to study soil-pore structure. Results for all soil samples showed that at the beginning of soil samples wetting the CO2 emission increased because of improving condition for microbes' activity. The maximum values were reached for soil column average soil water content between 0.10 and 0.15 cm3/cm3. Next CO2 emission decreased since the pore system starts filling by water (i.e. aggravated conditions for microbes, closing soil gas pathways etc.). In the case of H2O exchange rate, values increased with increasing soil water contents (up to 0.15-0.20 cm3/cm3) and then remained approximately constant. Acknowledgement: Authors acknowledge the financial support of the Ministry of Agriculture of the Czech Republic No. QJ1230319
Relationship Between Perceived Risk of Falling and Adoption of Precautions to Reduce Fall Risk.
Blalock, Susan J; Gildner, Paula L; Jones, Jennifer L; Bowling, James M; Casteel, Carri H
2016-06-01
To better understand the relationship between perceived risk of falling and awareness and adoption of four specific precautions that older adults have taken to reduce this risk. Cross-sectional. Data were collected in in-person interviews conducted in the homes of study participants. Interviews conducted between March 2011 and September 2013 and lasted an average of 60-90 minutes. A stratified sampling strategy designed to enroll an equal number of homebound and nonhomebound participants was used. All participants (N = 164) were recruited from central North Carolina. Participants were asked about 1-year fall history, perceived risk of falling, restriction of activities because of fear of falling, awareness of four recommended fall prevention behaviors (exercise, annual medication review, bathroom grab bars, safe footwear), and current practice of these behaviors. In bivariate analyses, individuals who were aware of two behaviors recommended to reduce the risk of falling (exercise, use of safe footwear) and had adopted these behaviors perceived their risk of falling as lower than individuals who were aware of the recommended behaviors but had not adopted them. Moreover, in multivariate analyses, individuals who did not know that exercise is recommended to reduce the risk of falling perceived their risk of falling as lower than those who were aware of this recommendation and had adopted it. Individuals were least likely to be aware that medication reviews and exercise are recommended to reduce fall risk. Awareness of behaviors recommended to reduce fall risk appears necessary for adoption of these behaviors to reduce perceived risk. Fall-prevention campaigns should emphasize behaviors where awareness is low. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.
Distribution and habitat of Nitellopsis obtusa (Characeae) in the Laurentian Great Lakes
Schloesser, Donald W.; Hudson, Patrick L.; Nichols, S. Jerrine
1986-01-01
Nitellopsis obtusa, a macroalga (Characeae) native to Europe and Asia, was found in U.S. waters of the St. Clair-Detroit River system in 1983, thus extending the range of this taxon into the Laurentian Great Lakes about 850 km from the St. Lawrence River where it was first discovered in North America in 1978. Its occurrence only in water frequented by commercial shipping vessels suggests that it is distributed via this mechanism. In the St. Clair-Detroit River system, N. obtusa was collected with a Ponar grab at four locations, and with a grapnel at one additional location. It was the ninth most frequently found macrophyte and it was most abundant at Belle Isle in the Detroit River, where the mean dry-weight biomass in Ponar samples was 0 g m-2 in June, 37 g m-2 in August, and 32 g m−2 in September. Maximum biomass of this taxon in one Ponar grab at this location was 289 g m-2 in September. The alga occurred primarily in water of relatively low current velocity (11.3 cm s−1) and in association with Vallisneria americana, Myriophyllum spicatum, Potamogeton richardsonii, Najas flexilis, and Elodea canadensis.
Soyuz 23 Return Samples: Assessment of Air Quality Aboard the International Space Station
NASA Technical Reports Server (NTRS)
James, John T.
2011-01-01
Six mini-grab sample containers (m-GSCs) were returned aboard Soyuz 23 because of concerns that new air pollutants had been present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The TOC began to decline in late October, 2010. The toxicological assessment of 6 m-GSCs from the ISS is shown in Table 1. The recoveries of 13C-acetone, fluorobenzene, and chlorobenzene from the GSCs averaged 73, 82, and 59%, respectively. We are working to understand the sub-optimal recovery of chlorobenzene.
Ghosh, Samik; Kim, Ki-Hyun; Sohn, Jong Ryeul
2011-01-01
In this study, we have examined the patterns of VOCs released from used Tedlar bags that were once used for the collection under strong source activities. In this way, we attempted to account for the possible bias associated with the repetitive use of Tedlar bags. To this end, we selected the bags that were never heated. All of these target bags were used in ambient temperature (typically at or below 30°C). These bags were also dealt carefully to avoid any mechanical abrasion. This study will provide the essential information regarding the interaction between VOCs and Tedlar bag materials as a potential source of bias in bag sampling approaches. PMID:22235175
Ghosh, Samik; Kim, Ki-Hyun; Sohn, Jong Ryeul
2011-01-01
In this study, we have examined the patterns of VOCs released from used Tedlar bags that were once used for the collection under strong source activities. In this way, we attempted to account for the possible bias associated with the repetitive use of Tedlar bags. To this end, we selected the bags that were never heated. All of these target bags were used in ambient temperature (typically at or below 30°C). These bags were also dealt carefully to avoid any mechanical abrasion. This study will provide the essential information regarding the interaction between VOCs and Tedlar bag materials as a potential source of bias in bag sampling approaches.
Presley, Todd K.
2001-01-01
The State of Hawaii Department of Transportation Stormwater Monitoring Program was implemented on January 1, 2001. The program includes the collection of rainfall, streamflow, and water-quality data at selected sites in the Halawa Stream drainage basin. Rainfall and streamflow data were collected from July 1, 2000 to June 30, 2001. Few storms during the year met criteria for antecedent dry conditions or provided enough runoff to sample. The storm of June 5, 2001 was sufficiently large to cause runoff. On June 5, 2001, grab samples were collected at five sites along North Halawa and Halawa Streams. The five samples were later analyzed for nutrients, trace metals, oil and grease, total petroleum hydrocarbons, fecal coliform, biological and chemical oxygen demands, total suspended solids, and total dissolved solids.
An apparatus for preparing benthic samples aboard ship
Pepper, Phillip N.; Girard, Thomas L.; Stapanian, Martin A.
2001-01-01
We describe a safe and effective apparatus for washing and reducing the volume of benthic samples collected by grab samplers aboard ship. The sample is transferred directly from the dredge to the apparatus and then washed with water pumped through pipes in the apparatus and from onboard hoses. Wastewater and materials smaller than 0.541 mm in diameter are washed overboard. Larger materials, including benthic organisms, collect on an upper 0.64-cm screen and on a lower 30-mm-mesh stainless steel bolt cloth. A collection jar is screwed into the bottom of the apparatus. Therefore, transfer of sample material from the apparatus to the jar is quick and easy. This apparatus has several advantages for use aboard ship over others described in the literature, especially in rough seas, in cold weather, and at night. The apparatus provides a safe and convenient platform for washing and reducing samples, and samples can be prepared while the vessel is traveling at full speed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castaldini, C.; Waterland, L.R.
1987-03-01
The two-volume report gives results from field tests of a wood-waste-fired industrial watertube boiler. Two series of tests were performed: one firing dry (11% moisture) wood waste, and the other firing green (34% moisture) wood waste. Emission measurements included: continuous monitoring of flue-gas emissions; source-assessment sampling system (SASS) sampling of the flue gas with subsequent laboratory analysis of samples to give total flue-gas organics in two boiling-point ranges, compound category information within these ranges, specific quantitation of the semi-volatile organic priority pollutants, and flue-gas concentrations of 73 trace elements; Method 5 sampling for particulate; controlled condensation system sampling for SO/submore » 2/ and SO/sub 3/; and grab sampling of boiler mechanical collector hopper ash for inorganic composition determinations. Total organic emissions decreased from 60-135 mg/dscm firing dry wood to 2-65 mg/dscm firing green wood, in parallel with corresponding boiler CO emissions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castaldini, C.; Waterland, L.R.
1987-03-01
The two-volume report gives results from field tests of a wood-waste-fired industrial watertube boiler. Two series of tests were performed: one firing dry (11% moisture) wood waste, and the other firing green (34% moisture) wood waste. Emission measurements included: continuous monitoring of flue-gas emissions; source-assessment sampling system (SASS) sampling of the flue-gas with subsequent laboratory analysis of samples to give total flue-gas organics in two boiling-point ranges, compound category information within these ranges, specific quantitation of the semi-volatile organic priority pollutants, and flue gas concentrations of 73 trace elements; Method 5 sampling for particulate; controlled condensation system sampling for SO/submore » 2/ and SO/sub 3/; and grab sampling of boiler mechanical collector hopper ash for inorganic and organic composition determinations. Total organic emissions decreased from 60-135 mg/dscm firing dry wood to 2-65 mg/dscm firing green wood, in parallel with corresponding boiler CO emissions.« less
Barnhardt, W.A.; Kelley, J.T.; Dickson, S.M.; Belknap, D.F.
1998-01-01
The bedrock-framed seafloor in the northwestern Gulf of Maine is characterized by extreme changes in bathymetric relief and covered with a wide variety of surficial materials. Traditional methods of mapping cannot accurately represent the great heterogeneity of such a glaciated region. A new mapping scheme for complex seafloors, based primarily on the interpretation of side-scan sonar imagery, utilizes four easily recognized units: rock, gravel, sand and mud. In many places, however, the seafloor exhibits a complicated mixture or extremely 'patchy' distribution of the four basic units, which are too small to map individually. Twelve composite units, each a two-component mixture of the basic units, were established to represent this patchiness at a small scale (1:100,000). Using a geographic information system, these and all other available data (seismic profiles, grab samples, submersible dives and cores) were referenced to a common geographic base, superimposed on bathymetric contours and then integrated into surficial geologic maps of the regional inner continental shelf. This digital representation of the seafloor comprises a multidimensional, interactive model complete with explicit attributes (depth, bottom type) that allow for detailed analysis of marine environments.
Emissions of nitrous oxide from biomass burning
NASA Technical Reports Server (NTRS)
Winstead, Edward L.; Cofer, Wesley R., III; Levine, Joel S.
1991-01-01
A study has been conducted which compared N2O results obtained over large prescribed fires or wildfires, in which 'grab-sampling' with storage had been used with N2O measurements made in near-real time. CO2-normalized emission ratios obtained initially from the laboratory fires are substantially lower than those obtained over large-scale biomass fires. Combustion may not be the only source of N2O in large fire smoke plumes; physical, chemical, and biochemical processes in the soil may be altered by large biomass fires, leading to large N2O releases.
An investigation of noncompliant toilet room designs for assisted toileting.
Sanford, Jon; Bosch, Sheila J
2013-01-01
By comparing an Americans with Disabilities Act Accessibility Guidelines (ADAAG) compliant design with alternative designs, this pilot study resulted in recommendations for designing patient bathrooms to facilitate assisted toileting. The ADA Accessibility Guidelines were developed primarily to address the needs of disabled populations, such as returning Vietnam veterans, with sufficient upper body strength to transfer independently directly from a wheelchair to the toilet. However, the majority of older persons with disabilities (90%) stand to transfer to the toilet, rather than laterally moving from the wheelchair to the toilet. The research used a repeated measures research design to evaluate caregiver responses during assisted toileting for various toilet configurations. The study included 20 patients who were transferred onto and off of a toilet for each of four different configurations by one or two caregivers. Toileting trials were videotaped and analyzed by an occupational therapist. Additionally, caregivers completed five-question, self-report surveys after each toileting trial. Survey data indicate that staff members prefer the largest of the tested configurations, where the centerline of the toilet is 30 inches from the sidewall, rather than the 18 inches required by the ADAAG, and where there are two fold-down grab bars provided. Caregivers perceived the grab bar locations as better for helping them safely transfer subjects in a modified (non-ADAAG) configuration, and also that the grab bar style in a modified configuration (non-ADAAG) improved safety when transferring subjects. Although caregivers were observed to safely transfer residents to and from the toilet for all configurations tested, regulations regarding accessibility of patient bathrooms should acknowledge the perceived benefits of increasing the distance from the sidewall to the centerline of the toilet to as much as 30 inches and allowing two fold-down grab bars instead of the required sidewall and back-wall grab bars. ADA, toilet room design, healthcare design, evidence-based design, human factors, safety, staffPreferred Citation: Sanford, J., & Bosch, S. (2013). An investigation of noncompliant toilet room designs for assisted toileting. Health Environments Research & Design Journal 6(2), pp 43-57.
Analysis of commode grab bar usage for the monitoring of older adults in the smart home environment.
Arcelus, Amaya; Holtzman, Megan; Goubran, Rafik; Sveistrup, Heidi; Guitard, Paulette; Knoefel, Frank
2009-01-01
The occurrence of falls inside the home is a common yet potentially hazardous issue for adults as they age. Even with the installation of physical aids such as grab bars, weight transfers on and off a toilet or bathtub can become increasingly difficult as a person's level of physical mobility and sense of balance deteriorate. Detecting this deterioration becomes an important goal in fall prevention within a smart home. This paper develops an unobtrusive method of analyzing the usage of toilet grab bars using pressure sensors embedded into the arm rests of a commode. Clinical parameters are successfully extracted automatically from a series of stand-to-sit (StSi) and sit-to-stand (SiSt) transfers performed by a trial group of young and older adults. A preliminary comparison of the parameters indicates differences between the two groups, and aligns well with published characteristics obtained using accelerometers worn on the body. The unobtrusive nature of this method provides a useful tool to be incorporated into a system of continuous monitoring of older adults within the smart home environment.
The Water Footprint of Food Aid
NASA Astrophysics Data System (ADS)
Jackson, N. D.; Konar, M.; Hoekstra, A. Y.
2015-12-01
Food aid is a critical component of the global food system, particularly when emergency situations arise. For the first time, we evaluate the water footprint of food aid. To do this, we draw on food aid data from theWorld Food Programme and virtual water content estimates from WaterStat. We find that the total water footprint of food aid was 10 km3 in 2005, which represents approximately 0.5% of the water footprint of food trade and 2.0% of the water footprint of land grabbing (i.e., water appropriation associated with large agricultural land deals). The United States is by far the largest food aid donor and contributes 82% of the water footprint of food aid. The countries that receive the most water embodied in aid are Ethiopia, Sudan, North Korea, Bangladesh and Afghanistan. Notably, we find that there is significant overlap between countries that receive food aid and those that have their land grabbed. Multivariate regression results indicate that donor water footprints are driven by political and environmental variables, whereas recipient water footprints are driven by land grabbing and food indicators.
NASA Astrophysics Data System (ADS)
Liger, Lucie; Margoum, Christelle; Guillemain, Céline; Carluer, Nadia
2014-05-01
The implementation of the WFD (Water Framework Directive), requests European Union member states to achieve good qualitative and quantitative status of all water bodies in 2015. The monitoring of organic micropollutants such as pesticides is an essential step to assess the chemical and biological state of streams, to understand the reasons of degradation and to implement sound mitigation solutions in the watershed. In particular, the water sampling, which can be performed according to several strategies, has to be closely adapted to the experimental goals. In this study, we present and compare 3 different active sampling strategies: grab sampling, time-related and flow-dependent automatic samplings. In addition, the last two can be fractionated (i.e., several samples collected, and each one contained in a single bottle) or averaged (i.e., several samples mixed in the same bottle). Time-related samples allow the assessment of average exposure concentrations of organic micropollutants, whereas flow-dependent samples lead to average flux concentrations. The 3 sampling strategies were applied and compared during the monitoring of the pesticide contamination of a river located in a French vineyard watershed (the Morcille River, located 60 km north of Lyon, in the Beaujolais region). Data were collected between 2007 and 2011, during different seasons and for a range of hydrological events. The Morcille watershed is characterized by contrasted hydrological events with a very short-time response due to its small size (5 km²), steep slopes (20 to 28%) and highly permeable sandy soils. These features make it particularly difficult to monitor water quality, due to fast variations of pesticide concentrations depending on rain events. This comparative study is performed in 2 steps. At first, we compare the timestamps of each sample composing the weekly-averaged samples and those of the grab samples with hydrological data. This allows us to evaluate the efficiency of these 2 sampling strategies in the integration of flow variations and therefore pesticide concentration variations during the sampling campaign. In a second step, we use the fractionated samples data during flood events to calculate the concentrations of virtual averaged samples of the events. Different time or flow steps were used for the calculation, to assess their impact on the pesticide averaged-concentrations or fluxes. These analyses highlight the benefits and drawbacks of each sampling strategy. They show that the sampling strategy should be carefully chosen and designed depending on the final aim of the study and on the watershed characteristics (in particular its hydrological dynamics). This study may help to design future monitoring on water quality. Key Words: sampling strategies, surface water, concentration, flux, pesticides.
Sources of polychlorinated biphenyls to Devils Swamp Lake near Baton Rouge, Louisiana
Van Metre, Peter C.; Wilson, Jennifer T.; Kimball, Briant A.
2006-01-01
Devils Swamp Lake near Baton Rouge, Louisiana, created in 1973 by dredging in Devils Swamp along the Mississippi River, is contaminated with polychlorinated biphenyls (PCBs) from historical industrial discharges. This study involved the investigation of the occurrence, distribution, and sources of PCBs in the lake, including the possible historical contribution of PCBs from a hazardous-chemical disposal facility by way of a wastewater drainage ditch that was used from 1971 to 1993. Six bed sediment cores from the lake and three bed sediment grab samples from the drainage ditch were collected; 61 subsamples from selected intervals in five of the six cores and the three grab samples from the ditch were analyzed for PCBs using an immunoassay screening method. Sixteen of the core subsamples and one ditch sample were analyzed for organochlorine pesticides, PCBs, polycyclic aromatic hydrocarbons (PAHs) (15 samples), and major and trace elements. PCB congener profiles and a factor analysis of congener composition indicate that PCBs in sediment from the drainage ditch and in lake sediment deposited near the canal since the mid-1980s are similar, which indicates the disposal facility, by way of the wastewater drainage ditch, is the source of the PCBs. Sediment from several hundred meters down the lake to the west, near where Bayou Baton Rouge enters the lake, had a different PCB composition and in a sample deposited in the early 1980s, a much higher concentration, indicating a second source of PCBs in the watershed of Bayou Baton Rouge. Large differences in PAHs and metals between sediment near the ditch and sediment near Bayou Baton Rouge support this conclusion. The identity of the Bayou Baton Rouge source(s) cannot be established using available data. The short duration and relatively high concentrations of PCBs from the bayou source indicate either a spill or a flood-related release-there was a large flood on the Mississippi River in 1983. Older (deeper) samples from cores near the drainage ditch (dated as deposited before the mid-1980s) had PCB compositions that indicate a mixture of sources (Bayou Baton Rouge and the drainage ditch). Elevated PCB concentrations in sediment from the drainage ditch and cores from near the mouth of the ditch in recent (post-2000) samples indicate that some PCB inputs from the ditch might still be occurring.
Temporal pattern of toxicity in runoff from the Tijuana River Watershed.
Gersberg, Richard M; Daft, Daniel; Yorkey, Darryl
2004-02-01
Samples were collected from the Tijuana River under both dry weather (baseflow) conditions and during wet weather, and tested for toxicity using Ceriodaphnia dubia tests. Toxicity of waters in the Tijuana River was generally low under baseflow conditions, but increased markedly during high flow runoff events. In order to determine the temporal pattern of toxicity during individual rain events, sequential grab samples were collected using an autosampler at 5-7 h intervals after the start of the rain event, and tested for acute toxicity. In all cases, peak toxicity values (ranging from 2.8 to 5.8TU) for each storm occurred within the first 1-2 h of initiation of the rain event, and were statistically higher (using the 95% CL) for each of the pre-storm base flow values. However, there was no statistically significant correlation (p<0.05) between flow rate and toxicity when all storm data was pooled. Additionally, we used toxicity identification evaluation (TIE) procedures to attempt to identify the classes of chemicals that account for this early storm toxicity. Solid phase extraction was the only treatment that showed consistent and significant (P<0.05) removal of toxicity. These TIEs, conducted on the most toxic sample of the river's flow during runoff events, suggest that non-polar organics may be responsible for such toxicity. The temporal pattern of toxicity, both during a given storm event and seasonally, indicates that wash-off from the watershed by rainfall may deplete the supply of toxicity available for wash-off in subsequent events, so that a clearly consistent relationship between flow and toxicity was not evident.
NASA Astrophysics Data System (ADS)
Jollymore, A. J.; Johnson, M. S.; Hawthorne, I.
2013-12-01
Justification: Forest harvest effects on water quality can signal alterations in hydrologic and ecologic processes incurred as a result of forest harvest activities. Organic matter (OM), specifically dissolved organic carbon (DOC), plays a number of important roles mediating UV-light penetration, redox reactivity and microbial activity within aquatic ecosystems. Quantification of DOC is typically pursued via grab sampling followed by chemical or spectrophotometric analysis, limiting the temporal resolution obtained as well as the accuracy of export calculations. The advent of field-deployable sensors capable of measuring DOC concentration and certain quality characteristics in situ provides the ability to observe dynamics at temporal scales necessary for accurate calculation of DOC flux, as well as the observation of dynamic changes in DOC quality on timescales impossible to observe through grab sampling. Methods: This study utilizes a field deployable UV-Vis spectrophotometer (spectro::lyzer, s::can, Austria) to investigate how forest harvest affects DOC export. The sensor was installed at an existing hydrologic monitoring site at the outlet of a headwater stream draining a small (91 hectare) second growth Douglasfir-dominated catchment near Campbell River on Vancouver Island, British Columbia. Measurement began late in 2009, prior to forest harvest and associated activities such as road building (which commenced in October 2010 and ended in early 2011), and continues to present. During this time - encompassing the pre, during and post-harvest conditions - the absorbance spectrum of stream water from 200 to 750 nm was measured. DOC concentration and spectroscopic indices related to DOC quality (including SUVA, which relates to the concentration of aromatic carbon, and spectral slope) were subsequently calculated for each spectra obtained at 30-minute intervals. Results and conclusions: High frequency measurements of DOC show that overall export of OM increased in the months following harvest. A major advantage of this study is the use of in situ measurements, allowing for high temporal resolution of DOC dynamics occurring within specific hydrologic events. For example, concentration-discharge relationships for both the pre- and post-logging periods demonstrate similar clockwise hysteresis during individual storm events, while the magnitude of change dramatically increased during the post-logging period. However, in situ measurements of SUVA over this period suggest that DOC quality may be less affected by forest harvest than overall DOC concentration, where high frequency data also allows for the observation of SUVA and spectral slope responses to specific hydrologic events during the pre- and post- harvest period.
137Cs as a tracer of recent sedimentary processes in Lake Michigan
Cahill, R.A.; Steele, J.D.
1986-01-01
To determine recent sediment movement, we measured the levels of 137Cs (an artificial radionuclide produced during nuclear weapons testing) of 118 southern Lake Michigan samples and 27 in Green Bay. These samples, taken from 286 grab samples of the upper 3 cm of sediment, were collected in 1975 as part of a systematic study of Lake Michigan sediment. 137Cs levels correlated well with concentrations of organic carbon, lead, and other anthropogenic trace metals in the sediment. 137Cs had a higher correlation with silt-sized than with clay-sized sediment (0.55 and 0.46, respectively). Atmospherically derived 137Cs and trace metals are being redistributed by sedimentary processes in Lake Michigan after being incorporated in suspended sediment. We determined a distribution pattern of 137Cs that represents areas of southern Lake Michigan where sediment deposition is occurring. ?? 1986 Dr W. Junk Publishers.
Volcanic gas emissions and their impact on ambient air character at Kilauea Volcano, Hawaii
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutton, A.J.; Elias, T.; Navarrete, R.
1994-12-31
Gas emissions from Kilauea occur from the summit caldera, along the middle East Rift Zone (ERZ), and where lava enters the ocean. We estimate that the current ERZ eruption of Kilauea releases between 400 metric tonnes of SO{sub 2} per day, during eruptive pauses, to as much as 1850 metric tonnes per day during actively erupting periods, along with lesser amounts of other chemically and radiatively active species including H{sub 2}S, HCl and HF. In order to characterize gas emissions from Kilauea in a meaningful way for assessing environmental impact, we made a series of replicate grab-sample measurements of ambientmore » air and precipitation at the summit of Kilauea, along its ERZ, and at coastal sites where lava enters the ocean. The grab-sampling data combined with SO{sub 2} emission rates, and continuous air quality and meteorological monitoring at the summit of Kilauea show that the effects of these emissions on ambient air character are a complex function of chemical reactivity, source geometry and effusivity, and local meteorology. Prevailing tradewinds typically carry the gases and aerosols released to the southwest, where they are further distributed by the regional wind regime. Episodes of kona, or low speed variable winds sometimes disrupt this pattern, however, and allow the gases and their oxidation products to collect at the summit and eastern side of the island. Summit solfatara areas of Kilauea are distinguished by moderate to high ambient SO{sub 2}, high H{sub 2}S at one location, and low H{sub 2}S at all others, and negligible HCl concentrations, as measured 1 m from degassing point-sources. Summit solfatara rain water has high sulfate and low chloride ion concentrations, and low pH.« less
Method for Cleanly and Precisely Breaking Off a Rock Core Using a Radial Compressive Force
NASA Technical Reports Server (NTRS)
Richardson, Megan; Lin, Justin
2011-01-01
The Mars Sample Return mission has the goal to drill, break off, and retain rock core samples. After some results gained from rock core mechanics testing, the realization that scoring teeth would cleanly break off the core after only a few millimeters of penetration, and noting that rocks are weak in tension, the idea was developed to use symmetric wedging teeth in compression to weaken and then break the core at the contact plane. This concept was developed as a response to the break-off and retention requirements. The wedges wrap around the estimated average diameter of the core to get as many contact locations as possible, and are then pushed inward, radially, through the core towards one another. This starts a crack and begins to apply opposing forces inside the core to propagate the crack across the plane of contact. The advantage is in the simplicity. Only two teeth are needed to break five varieties of Mars-like rock cores with limited penetration and reasonable forces. Its major advantage is that it does not require any length of rock to be attached to the parent in order to break the core at the desired location. Test data shows that some rocks break off on their own into segments or break off into discs. This idea would grab and retain a disc, push some discs upward and others out, or grab a segment, break it at the contact plane, and retain the portion inside of the device. It also does this with few moving parts in a simple, space-efficient design. This discovery could be implemented into a coring drill bit to precisely break off and retain any size rock core.
NASA Astrophysics Data System (ADS)
Wang, A.; Tao, C.; Xu, Y.; Zhang, G.; Liao, S.
2016-12-01
The inactive Duanqiao hydrothermal field is located on the 50.5°E SWIR axial high with a shallow depth of about 1700 meters. Seafloor morphology of the area surrounding the field is relatively flat, which exerts less influence on multibeam backscatter data than rugged terrains do. Therefore, it is an ideal experimental area to conduct seafloor classification utilizing multibeam sonar. This paper dealt with a backscatter analysis of Simrad EM120 multibeam sonar data, acquired during the Chinese DY115-34 cruise near the Duanqiao hydrothermal field, and comprehensively studied types and distribution characteristics of seafloor substrate by combining with visual interpretations and TV-Grab Samples. Firstly, a mosaic was built to analyze backscatter distribution after multibeam backscatter data were fully processed using Geocoder engine on CARIS HIPS&SIPS software. Prior information was gained by analyzing the link between the processed backscatter data and the visual interpretations of two deep-tow video survey lines. Among the two survey lines, one corresponds to sediment-dominated seafloor and the other corresponds to pillow basalt-dominated seafloor. Then, backscatter data of the mosaic were classified statistically to identify three types of seafloor: soft substrate, medium-hard substrate and hard substrate. Compared with visual interpretations and TV-Grab Samples, these three seafloor types were interpreted as sediment, breccia and pillow basalt, respectively. Finally, a seafloor classification map was generated. According to the results, we discovered two distinguished distribution characteristics of seafloor substrate: 1. there is a transition from pillow basalt-dominated seafloor to sediment-dominated seafloor away from the SWIR axis; 2. the Duanqiao hydrothermal field is mostly outcropped by pillow basalts and locally covered by breccias and sediments, the reason of which is probably that this field is a relatively recent volcanic area.
NASA Technical Reports Server (NTRS)
Lebel, P. J.; Lamontagne, R. A.; Goldstein, H. W.
1976-01-01
The Carbon Monoxide Pollution Experiment (COPE) and the National Capital Air Quality Control Region (NCAQCR) undertook a series of measurements of atmospheric CO and CH4 to determine the accuracy of the airborne COPE Correlation Interfer4meter. The device, a modified Michelson interferometer, measures the atmospheric column density of CO and CH4 at 2.3 microns with tropospheric measurement sensitivities of 70 and 10 PPB, respectively. Data for evaluating the remote measurements included atmospheric column density measurements at a ground truth site using a van-mounted infrared Fourier spectrometer; continuous ground level gas chromatographic measurements; and chromatographic data from atmospheric grab samples collected by aircraft and at ground locations. The instruments and sampling techniques used in the experiment are described in detail.
Food-service establishment wastewater characterization.
Lesikar, B J; Garza, O A; Persyn, R A; Kenimer, A L; Anderson, M T
2006-08-01
Food-service establishments that use on-site wastewater treatment systems are experiencing pretreatment system and/or drain field hydraulic and/or organic overloading. This study included characterization of four wastewater parameters (five-day biochemical oxygen demand [BOD5]; total suspended solids [TSS]; food, oil, and grease [FOG]; and flow) from 28 restaurants located in Texas during June, July, and August 2002. The field sampling methodology included taking a grab sample from each restaurant for 6 consecutive days at approximately the same time each day, followed by a 2-week break, and then sampling again for another 6 consecutive days, for a total of 12 samples per restaurant and 336 total observations. The analysis indicates higher organic (BOD5) and hydraulic values for restaurants than those typically found in the literature. The design values for this study for BOD5, TSS, FOG, and flow were 1523, 664, and 197 mg/L, and 96 L/day-seat respectively, which captured over 80% of the data collected.
Zhang, Heqing; Yamada, Harumi; Tsuno, Hiroshi
2008-05-01
The decomposition of endocrine-disrupting chemicals (EDCs) including estrone (E1), 17beta-estradiol (E2), estriol (E3), nonylphenol (NP), and bisphenol A (BPA) during ozonation of municipal sewage grabbed from the outlets of primary sedimentation tanks was studied through laboratory-scale experiments. A newly developed in vitro bioassay called nuclear receptor-ligand assay and GC-MS were both utilized to respectively determine the estrogenicity and individual EDCs in the wastewater samples. The original estrogenicity, expressed as the E2 equivalent concentration (EEQC), in the primary effluents was 315-1018 ng/L. Results indicate that the EEQC can be reduced rapidly to below 10 ng/L after ozonation. The appearance of 0.1 mg/L dissolved ozone (DO3), which corresponds to a consumed ozone amount of 0.4 mg per initial TOC (total organic carbon) of wastewater samples, was an appropriate operational parameter to simultaneously achieve efficient EDC removal and control of BrO3- and total organic bromine (TOBr). The presence of suspended solids in the range of 38-67 mg/L exhibited no obvious impact on the removal of nonsorbed estrogenicity. A complete decomposition of E2, E3 and BPA was achieved once 0.1 mg/L DO3 appeared in the primary effluent. The oxidative decomposition of NP was relatively less efficient with a residual concentration of 100 ng/L. This work investigates the feasibility of EDC removal and brominated byproduct control during ozonation of original municipal sewage prior to biological treatment.
Comparative analysis of hydroacoustic lakebed classification in three different Brazilian reservoirs
NASA Astrophysics Data System (ADS)
Hilgert, Stephan; Sotiri, Klajdi; Fuchs, Stephan
2017-04-01
Until today, the surface of artificial water bodies around the world reached an area of around 500,000 km2 equaling one third of the surface of natural water bodies. Most of the constructed waster bodies are reservoirs with a variety of usage purposes, reaching from drinking water supply, electricity production, flood protection to recreation. All reservoirs have in common, that they disrupt riverine systems and their biochemical cycles and promote the accumulation of sediments upstream of the dam. The accumulated sediments contain organic matter, nutrients and/or pollutants which have a direct influence on the water quality within the impoundment. Consequently, detailed knowledge about the amount and the quality of accumulated sediments is an essential information for reservoir management. In many cases the extensive areas covered by the impoundments make it difficult and expensive to assess sediment characteristics with a high spatial resolution. Spatial extrapolations and mass balances based on point information may suffer from strong deviations. We combined sediment point measurements (core and grab sampling) with hydroacoustic sediment classification in order to precisely map sediment parameters. Three different reservoirs (Vossoroca, Capivari, Passauna) in the south-east of Brazil were investigated between 2011 and 2015. A single beam echosounder (EA 400, Kongsberg) with two frequencies (200 & 38 kHz) was used for the hydroacoustic classification. Over 50 core samples and 30 grab samples were taken for physical and chemical analysis to serve as ground truthing of the hydroacoustic measurements. All three reservoirs were covered with dense measurement transects allowing for a lakebed classification of the entire sediment surface. Significant correlations of physical parameters like grain size distribution and density as well chemical parameters like organic carbon content and total phosphorous with a selection of hydroacoustic parameters were obtained. They enabled the derivation of empiric models used for the extrapolation of the sediment point information to the entire reservoir surface. With the obtained spatial information carbon and phosphorous budgets were calculated. Former stock calculations, which were based solely on point sampling, could be improved The results show that the method is transferable to different reservoirs with varying characteristics in regard of their catchments, morphology and trophic state.
Cooper, K M; Barry, J
2017-09-29
In this study we produce a standardised dataset for benthic macrofauna and sediments through integration of data (33,198 samples) from 777 grab surveys. The resulting dataset is used to identify spatial and temporal patterns in faunal distribution around the UK, and the role of sediment composition and other explanatory variables in determining such patterns. We show how insight into natural variability afforded by the dataset can be used to improve the sustainability of activities which affect sediment composition, by identifying conditions which should remain favourable for faunal recolonisation. Other big data applications and uses of the dataset are discussed.
Evaluation of radiometric and geometric characteristics of LANDSAT-D imaging system
NASA Technical Reports Server (NTRS)
Salisbury, J. W.; Podwysocki, M. H.; Bender, L. U.; Rowan, L. C. (Principal Investigator)
1983-01-01
With vegetation masked and noise sources eliminated or minimized, different carbonate facies could be discriminated in a south Florida scene. Laboratory spectra of grab samples indicate that a 20% change in depth of the carbonate absorption band was detected despite the effects of atmospheric absorption. Both bright and dark hydrothermally altered volcanic rocks can be discriminated from their unaltered equivalents. A previously unrecognized altered area was identified on the basis of the TM images. The ability to map desert varnish in semi-arid terrains has economic significance as it defines areas that are less susceptible desert erosional process and suitable for construction development.
Photonic Microhand with Autonomous Action.
Martella, Daniele; Nocentini, Sara; Nuzhdin, Dmitry; Parmeggiani, Camilla; Wiersma, Diederik S
2017-11-01
Grabbing and holding objects at the microscale is a complex function, even for microscopic living animals. Inspired by the hominid-type hand, a microscopic equivalent able to catch microelements is engineered. This microhand is light sensitive and can be either remotely controlled by optical illumination or can act autonomously and grab small particles on the basis of their optical properties. Since the energy is delivered optically, without the need for wires or batteries, the artificial hand can be shrunk down to the micrometer scale. Soft material is used, in particular, a custom-made liquid-crystal network that is patterned by a photolithographic technique. The elastic reshaping properties of this material allow finger movement, using environmental light as the only energy source. The hand can be either controlled externally (via the light field), or else the conditions in which it autonomously grabs a particle in its vicinity can be created. This microrobot has the unique feature that it can distinguish between particles of different colors and gray levels. The realization of this autonomous hand constitutes a crucial element in the development of microscopic creatures that can perform tasks without human intervention and self-organized automation at the micrometer scale. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hoi, Tran Xuan; Phuong, Huynh Truc; Van Hung, Nguyen
2016-09-01
During the production of iodine-131 from neutron irradiated tellurium dioxide by the dry distillation, a considerable amount of (131)I vapor is dispersed to the indoor air. People who routinely work at the production area may result in a significant risk of exposure to chronic intake by inhaled (131)I. This study aims to estimate the inhalation dose for individuals manipulating the (131)I at a radioisotope production. By using an application installed on smartphones, we collected the time-microenvironment data spent by a radiation group during work days in 2015. Simultaneously, we used a portable air sampler combined with radioiodine cartridges for grabbing the indoor air samples and then the daily averaged (131)I concentration was calculated. Finally, the time-microenvironment data jointed with the concentration to estimate the inhalation dose for the workers. The result showed that most of the workers had the annual internal dose in 1÷6mSv. We concluded that using smartphone as a motion detector is a possible and reliable way instead of the questionnaires, diary or GPS-based method. It is, however, only suitable for monitoring on fixed indoor environments and limited the targeted people. Copyright © 2016 Elsevier Ltd. All rights reserved.
Besmer, Michael D.; Weissbrodt, David G.; Kratochvil, Bradley E.; Sigrist, Jürg A.; Weyland, Mathias S.; Hammes, Frederik
2014-01-01
Fluorescent staining coupled with flow cytometry (FCM) is often used for the monitoring, quantification and characterization of bacteria in engineered and environmental aquatic ecosystems including seawater, freshwater, drinking water, wastewater, and industrial bioreactors. However, infrequent grab sampling hampers accurate characterization and subsequent understanding of microbial dynamics in all of these ecosystems. A logic technological progression is high throughput and full automation of the sampling, staining, measurement, and data analysis steps. Here we assess the feasibility and applicability of automated FCM by means of actual data sets produced with prototype instrumentation. As proof-of-concept we demonstrate examples of microbial dynamics in (i) flowing tap water from a municipal drinking water supply network and (ii) river water from a small creek subject to two rainfall events. In both cases, automated measurements were done at 15-min intervals during 12–14 consecutive days, yielding more than 1000 individual data points for each ecosystem. The extensive data sets derived from the automated measurements allowed for the establishment of baseline data for each ecosystem, as well as for the recognition of daily variations and specific events that would most likely be missed (or miss-characterized) by infrequent sampling. In addition, the online FCM data from the river water was combined and correlated with online measurements of abiotic parameters, showing considerable potential for a better understanding of cause-and-effect relationships in aquatic ecosystems. Although several challenges remain, the successful operation of an automated online FCM system and the basic interpretation of the resulting data sets represent a breakthrough toward the eventual establishment of fully automated online microbiological monitoring technologies. PMID:24917858
Macrobenthic molluscs from a marine - lagoonal environmental transition in Lesvos Island (Greece).
Evagelopoulos, Athanasios; Koutsoubas, Drosos; Gerovasileiou, Vasilis; Katsiaras, Nikolaos
2016-01-01
This paper describes an occurence dataset, also including numerical abundance and biomass data, pertaining to the macrobenthic molluscan assemblages from a marine - lagoonal environmental transition. The study system was the soft-substrate benthoscape of the area of the Kalloni solar saltworks (Lesvos Island, Greece). Specifically, the study area extended from the infralittoral zone of the inner Kalloni Gulf (marine habitat) to the bottoms of the first two evaporation ponds of the Kalloni solar saltworks (lagoonal habitat). Bottom sediment samples (3 replicates) were collected with a Van Veen grab sampler (0.1 m 2 ) at four sampling sites, along a 1.5 km long line transect that spanned the marine - lagoonal environmental transition. A total of four surveys were carried out seasonally in 2004. A total of 39,345 molluscan individuals were sorted out of the sediment samples and were identified to 71 species, belonging to the Gastropoda (36), Bivalvia (34) and Scaphopoda (1) classes. Numerical abundance and wet biomass (with shells) data are included in the dataset. The dataset described in the present paper partially fills a significant gap in the scientific literature: Because ecological research of coastal lagoons has seldom explicitly considered the marine - lagoonal habitats interface, there are no openly accessible datasets pertaining to the particular structural component of the transitional waters benthoscapes of the Mediterranean Sea. Such datasets could prove valuable in the research of the structure and functioning of transitional waters benthoscapes. The present dataset is available as a supplementary file (Suppl. material 1) and can also be accessed at http://ipt.medobis.eu/resource?r=kalloni_saltworks_phd.
Currie, D R; Isaacs, Leanne R
2005-04-01
Changes to benthic infauna caused by exploratory gas drilling operations in the Minerva field were examined experimentally using a BACI (before, after, control, impact) design. Analysis of 72 x 0.1 m2 Smith-McIntyre grab samples obtained from one pre-drilling and three post-drilling periods yielded a diverse fauna consisting of 196 invertebrate species and 5035 individuals. Changes to benthic community structure were assessed using ANOVA and nonmetric multidimensional scaling (MDS). The abundances of two common species (Apseudes sp. 1 and Prionospio coorilla) decreased significantly at the well-head site immediately after drilling. The size of these reductions in abundance ranged between 71% and 88%, and persisted for less than 4 months after drilling. A third common species (Katlysia sp. 1) increased in abundance 200 m east of the well-head following drilling. Most species occurred at densities too low to be analysed individually and so were pooled at higher taxonomic levels. Changes in the abundance of species aggregated by phylum varied, but significant declines in the most abundant phyla (Crustaceans and Polychaetes) of 45-73% were observed at all sites within a 100 m radius of the well-head following drilling. In most cases these changes became undetectable four months after drilling following species recruitments. MDS ordinations confirm that drilling related changes to benthic community structure are most pronounced at stations located closest to the well-head. Additionally, the ordinations indicate that modified communities persist at the well-head for more than 11 months following exploratory drilling.
Intercomparison of active and passive instruments for radon and radon progeny in North America
DOE Office of Scientific and Technical Information (OSTI.GOV)
George, A.C.; Tu, Keng-Wu; Knutson, E.O.
1995-02-01
An intercomparison exercise for radon and radon progeny instruments and methods was held at the Environmental Measurements Laboratory (EML) from April 22--May 2, 1994. The exercise was conducted in the new EML radon test and calibration facility in which conditions of exposure are very well controlled. The detection systems of the intercompared instruments consisted of. (1) pulse ionization chambers, (2) electret ionization chambers, (3) scintillation detectors, (4) alpha particle spectrometers with silicon diodes, surface barrier or diffused junction detectors, (5) registration of nuclear tracks in solid-state materials, and (6) activated carbon collectors counted by gamma-ray spectrometry or by alpha- andmore » beta-liquid scintillation counting. 23 private firms, government laboratories and universities participated with a 165 passive integrating devices consisting of: Activated carbon collectors, nuclear alpha track detectors and electret ionization chambers, and 11 active and passive continuous radon monitors. Five portable integrating and continuous instruments were intercompared for radon progeny. Forty grab samples for radon progeny were taken by five groups that participated in person to test and evaluate their primary instruments and methods that measure individual radon progeny and the potential alpha energy concentration (PAEC) in indoor air. Results indicate that more than 80% of the measurements for radon performed with a variety of instruments, are within {plus_minus}10% of actual value. The majority of the instruments that measure individual radon progeny and the PAEC gave results that are in good agreement with the EML reference value. Radon progeny measurements made with continuous and integrating instruments are satisfactory with room for improvement.« less
NASA Technical Reports Server (NTRS)
James, John T.
2001-01-01
The toxicological assessment of air samples returned at the end of the STS-100 (6A) flight to the ISS is reported. ISS air samples were taken in March and April 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. An unplanned "first-entry" sample of the MPLM2 (multipurpose logistics module) atmosphere was taken with a GSC, and preflight and end-of-mission samples were obtained from Endeavour using GSCs. Analytical methods have not changed from earlier reports, and all quality control measures were met for the data presented herein. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contribution). Because of the Freon 218 (octafluoropropane, OFP) leak, its contribution to the NMVOC is indicated in brackets. When comparing the NMVOC values with the 25 mg/cubic m guideline, the OFP contributions should be subtracted. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols were also assessed in each sample.
Kennedy, Matthew Joel; Arcelus, Amaya; Guitard, Paulette; Goubran, R A; Sveistrup, Heidi
2015-01-01
Multiple toilet grab-bar configurations are required by people with a diverse spectrum of disability. The study purpose was to determine toilet grab-bar preference of healthy seniors, seniors with a hip replacement, and seniors post-stroke, and to determine the effect of each configuration on centre of pressure (COP) displacement during toilet transfers. 14 healthy seniors, 7 ambulatory seniors with a hip replacement, and 8 ambulatory seniors post-stroke participated in the study. Toilet transfers were performed with no bars (NB), commode (C), two vertical bars (2VB), one vertical bar (1VB), a horizontal bar (H), two swing-away bars (S) and a diagonal bar (D). COP was measured using pressure sensitive floor mats. Participants rated the safety, ease of use, helpfulness, comfort and preference for instalment. 2VB was most preferred and had the smallest COP deviation. Least preferred was H and NB. C caused largest COP displacement but had favourable ratings. The preference and safety of the 2VB should be considered in the design of accessible toilets and in accessibility construction guidelines. However these results need to be verified in non-ambulatory populations. C is frequently prescribed, but generates large COP deviation, suggesting it may present an increased risk of falls.
NASA JSC water monitor system: City of Houston field demonstration
NASA Technical Reports Server (NTRS)
Taylor, R. E.; Jeffers, E. L.; Fricks, D. H.
1979-01-01
A water quality monitoring system with on-line and real time operation similar to the function in a spacecraft was investigated. A system with the capability to determine conformance to future high effluent quality standards and to increase the potential for reclamation and reuse of water was designed. Although all system capabilities were not verified in the initial field trial, fully automated operation over a sustained period with only routine manual adjustments was accomplished. Two major points were demonstrated: (1) the water monitor system has great potential in water monitoring and/or process control applications; and (2) the water monitor system represents a vast improvement over conventional (grab sample) water monitoring techniques.
NASA Technical Reports Server (NTRS)
James, John T.
2002-01-01
The toxicological assessment of grab sample canisters (GSCs) returned aboard STS-110 is reported. Analytical methods have not changed from earlier reports, and surrogate standard recoveries from the GSCs were 77-121%, with one exception. Pressure tracking indicated no leaks in the canisters. Recoveries from lab and trip controls for formaldehyde analyses ranged from 87 to 96%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). Because of the inertness of Freon 218 (octafluoropropane, OFP), its contribution to the NMVOC is subtracted and tabulated separately. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols are also shown for each sample. Because formaldehyde is quantified from sorbent badges, its concentration is listed separately. These five indices of air quality are summarized.
Natural organic matter properties in Swedish agricultural streams
NASA Astrophysics Data System (ADS)
Bieroza, Magdalena; Kyllmar, Katarina; Bergström, Lars; Köhler, Stephan
2017-04-01
The following paper shows natural organic matter (NOM) properties of stream water samples collected from 8 agricultural streams and 12 agricultural observational fields in Sweden. The catchments and observational fields cover a broad range of environmental (climate, soil type), land use and water quality (nutrient and concentrations, pH, alkalinity) characteristics. Stream water samples collected every two weeks within an ongoing Swedish Monitoring Programme for Agriculture have been analysed for total/dissolved organic carbon, absorbance and fluorescence spectroscopy. A number of quantitative and qualitative spectroscopic parameters was calculated to help to distinguish between terrestrially-derived, refractory organic material and autochthonous, labile material indicative of biogeochemical transformations of terrestrial NOM and recent biological production. The study provides insights into organic matter properties and carbon budgets in agricultural streams and improves understanding of how agricultural catchments transform natural and anthropogenic fluxes of organic matter and nutrients. The insights from the grab sampling are supported by high-frequency turbidity, fulvic-like and tryptophan-like fluorescence measurements with in situ optical sensor.
Relating Optical Properties of Dusts to their Mineralogical and Physical Interrelationships
NASA Astrophysics Data System (ADS)
Engelbrecht, J. P.; Moosmuller, H.; Jayanty, R. K. M.; Casuccio, G.; Pincock, S. L.
2015-12-01
The purpose of the project was to provide information on the mineralogical, chemical and physical interrelationships of re-suspended mineral dust samples collected as grab samples from global dust sources. Surface soil samples were collected from about 65 desert sites, including the southwestern USA (12), Mali (3), Chad (3), Morocco (1), Canary Islands (8), Cape Verde (1), Djibouti (1), Afghanistan (3), Iraq (6), Kuwait (5), Qatar (1), UAE (1), Serbia (3), China (5), Namibia (3), Botswana (4), Australia (3), and Chile (1). The < 38 μm sieved fraction of each sample was re-suspended in an entrainment chamber, from which the airborne mineral dust could be monitored, sampled and analyzed. Instruments integrated into the entrainment facility included two PM10 and two PM2.5 filter samplers, a beta attenuation gauge for the continuous measurement of PM10 and PM2.5particulate mass fractions, an aerodynamic particle size (APS) analyzer, and a three wavelength (405, 532, 781nm) photoacoustic resonator with integrating reciprocal nephelometer for monitoring absorption and scattering coefficients during the dust re-suspension process. Filter sample media included Teflon® membrane and quartz fiber filters for chemical analysis (71 species), and Nuclepore® filters for individual particle analysis by Scanning Electron Microscopy (SEM). The < 38 μm sieved fractions were also analyzed by X-ray diffraction for their mineral content while the > 38 μm, < 125 μm soil fractions were mineralogically characterized by optical microscopy. We will be presenting results on the optical measurements, also showing the relationship between single scattering albedo (SSA) at three different wavelengths, and chemical as well as mineralogical content and interdependencies of the entrained dust samples. Examples showing the relationships between the single scattering albedos of airborne dusts, and iron (Fe) in hematite, goethite, and clay minerals (montmorillonite, illite, palygorskite), will be discussed. Our goal is to establish a database of the optical, mineralogical, and chemical properties of dust samples collected at multiple global dust sources. These data can be for applications in climate modeling, remote sensing, visibility, health (medical geology), ocean fertilization, and damage to equipment.
Mineralogical, Chemical, and Optical Interrelationships of Airborne Mineral Dusts
NASA Astrophysics Data System (ADS)
Engelbrecht, J. P.; Moosmuller, H.; Pincock, S. L.; Jayanty, R. K. M.; Casuccio, G.
2014-12-01
The purpose of the project was to provide information on the mineralogical, chemical and physical interrelationships of re-suspended mineral dust samples collected as grab samples from global dust sources. Surface soil samples were collected from about 65 desert sites, including the southwestern USA (12), Mali (3), Chad (3), Morocco (1), Canary Islands (8), Cape Verde (1), Djibouti (1), Afghanistan (3), Iraq (6), Kuwait (5), Qatar (1), UAE (1), Serbia (3), China (5), Namibia (3), Botswana (4), Australia (3), and Chile (1). The < 38 μm sieved fraction of each sample was re-suspended in an entrainment chamber, from which the airborne mineral dust could be monitored, sampled and analyzed. Instruments integrated into the entrainment facility included two PM10 and two PM2.5 filter samplers, a beta attenuation gauge for the continuous measurement of PM10 and PM2.5 particulate mass fractions, an aerodynamic particle size (APS) analyzer, and a three wavelength (405, 532, 781nm) photoacoustic resonator with integrating reciprocal nephelometer for monitoring absorption and scattering coefficients during the dust re-suspension process. Filter sample media included Teflon® membrane and quartz fiber filters for chemical analysis (71 species), and Nuclepore® filters for individual particle analysis by Scanning Electron Microscopy (SEM). The < 38 μm sieved fractions were also analyzed by X-ray diffraction for their mineral content while the > 38 μm, < 125 μm soil fractions were mineralogically characterized by optical microscopy. We will be presenting results on the optical measurements, also showing the relationship between single scattering albedo (SSA) at three different wavelengths, and chemical as well as mineralogical content and interdependencies of the entrained dust samples. Examples showing the relationships between the single scattering albedos of airborne dusts, and iron (Fe) in hematite, goethite, and clay minerals (montmorillonite, illite, palygorskite), will be discussed. Differences between the clay minerals in samples from Mali and those from other localities are demonstrated. We intend establishing a data base for applications in climate modeling, remote sensing, visibility, health (medical geology), ocean fertilization, and damage to equipment.
Malek, Salim; Melgani, Farid; Mekhalfi, Mohamed Lamine; Bazi, Yakoub
2017-11-16
This paper describes three coarse image description strategies, which are meant to promote a rough perception of surrounding objects for visually impaired individuals, with application to indoor spaces. The described algorithms operate on images (grabbed by the user, by means of a chest-mounted camera), and provide in output a list of objects that likely exist in his context across the indoor scene. In this regard, first, different colour, texture, and shape-based feature extractors are generated, followed by a feature learning step by means of AutoEncoder (AE) models. Second, the produced features are fused and fed into a multilabel classifier in order to list the potential objects. The conducted experiments point out that fusing a set of AE-learned features scores higher classification rates with respect to using the features individually. Furthermore, with respect to reference works, our method: (i) yields higher classification accuracies, and (ii) runs (at least four times) faster, which enables a potential full real-time application.
Ureteral stone surgery; Kidney stone - ureteroscopy; Ureteral stone removal - ureteroscopy; Calculi - ureteroscopy ... sent through the scope to grab and remove kidney stones or break them up using a laser. Place ...
Day, Warren C.; O'Neill, J. Michael
2008-01-01
The U.S. Geological Survey, in cooperation with the Alaska Department of Natural Resources Division of Mining, Land, and Water, has released a geologic map of the Big Delta B-1 quadrangle of east-central Alaska (Day and others, 2007). This companion report presents the major element oxide and trace element geochemical analyses, including those for gold, silver, and base metals, for representative rock units and for grab samples from quartz veins and mineralized zones within the quadrangle. Also included are field station locations, field notes, structural data, and field photographs based primarily on observations by W.C. Day with additions by J.M. O'Neill and B.M. Gamble, all of the U.S. Geological Survey. The data are provided in both Microsoft Excel spread sheet format and as a Microsoft Access database.
Earliest record of the invasive Foraminifera Trochammina hadai in San Francisco Bay, California, USA
McGann, Mary
2014-01-01
In 1995, Trochammina hadai, a benthic Foraminifera prevalent in Japanese estuaries, was found in San Francisco Bay, California, USA. Subsequent field investigations determined that the species was also present in nearly all of the major ports and estuaries along the western United States. Because of its widespread colonization, it is of interest to determine when T. hadai first appeared as an invasive in the coastal regions of the North Pacific. In San Francisco Bay, the species was not found in 404 surface samples collected between 1930 and 1981. In 1983, however, a grab sediment sample from one of four sites in the southern portion of the bay contained T. hadai. This site was the most northern of the four and contained 12 specimens of the invasive, comprising 1.5% of the assemblage. This is the earliest appearance on record of T. hadai in San Francisco Bay.
Assavasilavasukul, Prapakorn; Lau, Boris L T; Harrington, Gregory W; Hoffman, Rebecca M; Borchardt, Mark A
2008-05-01
The presence of waterborne enteric pathogens in municipal water supplies contributes risk to public health. To evaluate the removal of these pathogens in drinking water treatment processes, previous researchers have spiked raw waters with up to 10(6) pathogens/L in order to reliably detect the pathogens in treated water. These spike doses are 6-8 orders of magnitude higher than pathogen concentrations routinely observed in practice. In the present study, experiments were conducted with different sampling methods (i.e., grab versus continuous sampling) and initial pathogen concentrations ranging from 10(1) to 10(6) pathogens/L. Results showed that Cryptosporidium oocyst and Giardia cyst removal across conventional treatment were dependent on initial pathogen concentrations, with lower pathogen removals observed when lower initial pathogen spike doses were used. In addition, higher raw water turbidity appeared to result in higher log removal for both Cryptosporidium oocysts and Giardia cysts.
De Lange, H J; Van Griethuysen, C; Koelmans, A A
2008-01-01
Sediment treatment and sediment storage may alter sediment toxicity, and consequently biotic response. Purpose of our study was to combine these three aspects (treatment-toxicity-biotic response) in one integrated approach. We used Acid Volatile Sulfide (AVS) concentrations as a proxy of the disturbance of the sediment. AVS and Simultaneously Extracted Metal (SEM) concentrations were compared to bioassay responses with the freshwater benthic macroinvertebrate Asellus aquaticus. Storage conditions and sediment treatment affected AVS but not SEM levels. AVS can be used as a proxy for sediment disturbance. The best way to pretreat the sediment for use in a bioassay in order to maintain initial AVS conditions was to sample the sediment with an Ekman grab, immediately store it in a jar without headspace, and freeze it as soon as possible. In a survey using seven different sediments, bioassay responses of A. aquaticus were correlated with SEM and AVS characteristics.
Gourlay-Francé, C; Bressy, A; Uher, E; Lorgeoux, C
2011-01-01
The occurrence and the partitioning of polycyclic aromatic hydrocarbons (PAHs) and seven metals (Al, Cd, Cr, Cu, Ni, Pb and Zn) were investigated in activated sludge wastewater treatment plants by means of passive and active sampling. Concentrations total dissolved and particulate contaminants were determined in wastewater at several points across the treatment system by means of grab sampling. Truly dissolved PAHs were sampled by means of semipermeable membrane devices. Labile (inorganic and weakly complexed) dissolved metals were also sampled using the diffusive gradient in thin film technique. This study confirms the robustness and the validity of these two passive sampling techniques in wastewater. All contaminant concentrations decreased in wastewater along the treatment, although dissolved and labile concentrations sometimes increased for substances with less affinity with organic matter. Solid-liquid and dissolved organic matter/water partitioning constants were estimated. The high variability of both partitioning constants for a simple substance and the poor relation between K(D) and K(OW) shows that the binding capacities of particles and organic matter are not uniform within the treatment and that other process than equilibrium sorption affect contaminant repartition and fate in wastewater.
The theoretical background to BS7167: 1990 - specification for Bordeaux connections
NASA Astrophysics Data System (ADS)
Gorley, T. A. E.
1992-03-01
The theoretical background to the specification of Bordeaux connections (components of lifting gear used to join together wire rope and a chain, or two lengths of wire rope, where the joined lengths have to run over a sheave as in the case of grabbing cranes) is documented. Decisions taken in the drafting of earlier specifications are not documented. The design criteria for BS7167:1990 are addressed. The various parts of the Bordeaux connection specified in the standard are discussed in turn: the link portion, the rope portion, and the grab shackle. Some tests on the new design undertaken by the Health and Safety Executive confirm the new design criteria to be adequate for the strengths of rope to be used with this component.
Li, Ying; Yang, Cunman; Bao, Yijun; Ma, Xueru; Lu, Guanghua; Li, Yi
2016-08-01
A modified polar organic chemical integrative sampler (POCIS) could provide a convenient way of monitoring perfluorinated chemicals (PFCs) in water. In the present study, the modified POCIS was calibrated to monitor PFCs. The effects of water temperature, pH, and dissolved organic matter (DOM) on the sampling rate (R s) of PFCs were evaluated with a static renewal system. During laboratory validation over a 14-day period, the uptake kinetics of PFCs was linear with the POCIS. DOM and water temperature slightly influenced POCIS uptake rates, which is in consistent with the theory for uptake into POCIS. Therefore, within a narrow span of DOM and water temperatures, it was unnecessary to adjust the R s value for POCIS. Laboratory experiments were conducted with water over pH ranges of 3, 7, and 9. The R s values declined significantly with pH increase for PFCs. Although pH affected the uptake of PFCs, the effect was less than twofold. Application of the R s value to analyze PFCs with POCIS deployed in the field provided similar concentrations obtained from grab samples.
Coxon, T M; Odhiambo, B K; Giancarlo, L C
2016-10-15
The progressively declining ecological condition of the Chesapeake Bay is attributed to the influx of contaminants associated with sediment loads supplied by its largest tributaries. The continued urban expansion in the suburbs of Virginia cities, modern agricultural activities in the Shenandoah Valley, the anthropogenic and climate driven changes in fluvial system hydrodynamics and their potential associated impacts on trace metals enrichment in the bay's tributaries necessitate constant environmental monitoring of these important water bodies. Eight (210)Pb and (137)Cs dated sediment cores and seventy two sediment grab samples were used to analyze the spatial and temporal distributions of Al, Ca, Mg, Cr, Cd, As, Se, Pb, Cu, Zn, Mn, and Fe in the waterways of the Virginia portion of the Chesapeake Bay basin. The sediment cores for trace metal historical fluctuation analysis were obtained in lower fluvial-estuarine environments and reservoirs in the upper reaches of the basin. The trace metal profiles revealed high basal enrichment factors (EF) of between 0.05 and 40.24, which are interpreted to represent early nineteenth century agricultural activity and primary resource extraction. Surficial enrichment factors on both cores and surface grab samples ranged from 0.01 (Cu) to 1421 (Cd), with Pb, Cu, Zn, and Cd enrichments a plausible consequence of modern urban expansion and industrial development along major transportation corridors. Contemporary surficial enrichments of As, Se, and Cr also ranged between 0 and 137, with the higher values likely influenced by lithological and atmospheric sources. Pearson correlation analyses suggest mining and agricultural legacies, coupled with aerosol deposition, are responsible for high metal concentrations in western lakes and headwater reaches of fluvial systems, while metal accumulation in estuarine reaches of the major rivers can be attributed to urban effluence and the remobilization of legacy sediments. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Alamsyah, Andry; Rachmadiansyah, Imam
2018-03-01
Online transportation service is known for its accessibility, transparency, and tariff affordability. These points make online transportation have advantages over the existing conventional transportation service. Online transportation service is an example of disruptive technology that change the relationship between customers and companies. In Indonesia, there are high competition among online transportation provider, hence the companies must maintain and monitor their service level. To understand their position, we apply both sentiment analysis and multiclass classification to understand customer opinions. From negative sentiments, we can identify problems and establish problem-solving priorities. As a case study, we use the most popular online transportation provider in Indonesia: Gojek and Grab. Since many customers are actively give compliment and complain about company’s service level on Twitter, therefore we collect 61,721 tweets in Bahasa during one month observations. We apply Naive Bayes and Support Vector Machine methods to see which model perform best for our data. The result reveal Gojek has better service quality with 19.76% positive and 80.23% negative sentiments than Grab with 9.2% positive and 90.8% negative. The Gojek highest problem-solving priority is regarding application problems, while Grab is about unusable promos. The overall result shows general problems of both case study are related to accessibility dimension which indicate lack of capability to provide good digital access to the end users.
Wu, Shibin; Zhuang, Ling; Wei, Xinhua; Sak, Mark; Neb, Duric; Hu, Jiani; Xie, Yaoqin
2017-01-01
As an emerging modality for whole breast imaging, ultrasound tomography (UST), has been adopted for diagnostic purposes. Efficient segmentation of an entire breast in UST images plays an important role in quantitative tissue analysis and cancer diagnosis, while major existing methods suffer from considerable time consumption and intensive user interaction. This paper explores three-dimensional GrabCut (GC3D) for breast isolation in thirty reflection (B-mode) UST volumetric images. The algorithm can be conveniently initialized by localizing points to form a polygon, which covers the potential breast region. Moreover, two other variations of GrabCut and an active contour method were compared. Algorithm performance was evaluated from volume overlap ratios (TO, target overlap; MO, mean overlap; FP, false positive; FN, false negative) and time consumption. Experimental results indicate that GC3D considerably reduced the work load and achieved good performance (TO = 0.84; MO = 0.91; FP = 0.006; FN = 0.16) within an average of 1.2 min per volume. Furthermore, GC3D is not only user friendly, but also robust to various inputs, suggesting its great potential to facilitate clinical applications during whole-breast UST imaging. In the near future, the implemented GC3D can be easily automated to tackle B-mode UST volumetric images acquired from the updated imaging system. PMID:28786946
NASA Astrophysics Data System (ADS)
Birawida, A. B.; Selomo, M.; Mallongi, A.
2018-05-01
Coliform bacteria are suspected to come from faeces. As a result, their presence in various places ranging from drinking water, foodstuffs or other ingredients to human needs are not expected. This research aimed to describe bacterial contaminations, depot sanitations, equipment sanitations, worker hygiene, raw water quality, and refill drinking water in Barrang Lompo island in 2017. The observational research applied descriptive approach. Water samples collected grab from the drinking water depot taps, then examined using Most Probable Number (MPN) method. The results showed that three of six depots have qualified drinking water quality. Raw water samples from all depots indicated that none were eligible. The samples examined contained gram-negative bacteria. The types of bacteria that grew on the sample were Klebsiella pneumonia and Pseudomonas aerogenosa. In the environmental sanitation depots and worker hygiene, there was no one eligible. Sanitary appliances were all eligible and there were depots that used reserve osmosis methods and used combination methods between reserve osmosis and ultraviolet light. It was concluded that almost all samples of drinking water were contaminated by bacteria. Owners and depot workers were advised to improve and implement better hygiene and sanitation.
Toxicity of urban highway runoff with respect to storm duration.
Kayhanian, M; Stransky, C; Bay, S; Lau, S-L; Stenstrom, M K
2008-01-25
The toxicity of stormwater runoff during various time-based stages was measured in both grab and composite samples collected from three highly urbanized highway sites in Los Angeles, California between 2002 and 2005. Stormwater runoff samples were tested for toxicity using three freshwater species (the water flea Ceriodaphnia dubia, the fathead minnow Pimephales promelas, and the green algae Pseudokirchneriella subcapitatum) and two marine species (the purple sea urchin Strongylocentrotus purpuratus, and the luminescent bacteria Photobacterium phosphoreum using Microtox. Toxicity results varied substantially throughout the storm events for both freshwater and marine species toxicity tests. In general, however, the first few samples were found to be more toxic compared with those collected during later stages of each storm event. In most cases, more than 40% of the toxicity was associated with the first 20% of discharged runoff volume. Furthermore, on average, 90% of the toxicity was observed during the first 30% of storm duration. Toxicity identification evaluation results found copper and zinc to be the primary cause of toxicity in about 90% of the samples evaluated with these procedures. Surfactants were also found to be the cause of toxicity in less than 10% of the samples.
Afifi, Tracie O; Mota, Natalie; Sareen, Jitender; MacMillan, Harriet L
2017-05-23
Physical punishment of children is an important public health concern. Yet, few studies have examined how physical punishment is related to other types of child maltreatment and violence across the lifespan. Therefore, the objective of the current study was to examine if harsh physical punishment (i.e., being pushed, grabbed, shoved, hit, and/or slapped without causing marks, bruises, or injury) is associated with an increased likelihood of more severe childhood maltreatment (i.e., physical abuse, emotional abuse, sexual abuse, physical neglect, emotional neglect, and exposure to intimate partner violence (IPV)) in childhood and perpetration or victimization of IPV in adulthood. Data were drawn from the National Epidemiologic Survey on Alcohol and Related Conditions collected in 2004 to 2005 (n = 34,402, response rate = 86.7%), a representative United States adult sample. Harsh physical punishment was associated with increased odds of childhood maltreatment, including emotional abuse, sexual abuse, physical abuse, physical neglect, emotional neglect, and exposure to IPV after adjusting for sociodemographic factors, family history of dysfunction, and other child maltreatment types (range 1.6 to 26.6). Harsh physical punishment was also related to increased odds of experiencing IPV in adulthood (range 1.4 to 1.7). It is important for parents and professionals working with children to be aware that pushing, grabbing, shoving, hitting, or slapping children may increase the likelihood of emotional abuse, sexual abuse, physical abuse, physical neglect, emotional neglect, and exposure to IPV in childhood and also experiencing IPV victimization and/or perpetration in later adulthood.
NASA Technical Reports Server (NTRS)
Torres-Jara, Eduardo R.
2011-01-01
Tactile sensors are currently being designed to sense interactions with human hands or pen-like interfaces. They are generally embedded in screens, keyboards, mousepads, and pushbuttons. However, they are not well fitted to sense interactions with all kinds of objects. A novel sensor was originally designed to investigate robotics manipulation where not only the contact with an object needs to be detected, but also where the object needs to be held and manipulated. This tactile sensor has been designed with features that allow it to sense a large variety of objects in human environments. The sensor is capable of detecting forces coming from any direction. As a result, this sensor delivers a force vector with three components. In contrast to most of the tactile sensors that are flat, this one sticks out from the surface so that it is likely to come in contact with objects. The sensor conforms to the object with which it interacts. This augments the contact's surface, consequently reducing the stress applied to the object. This feature makes the sensor ideal for grabbing objects and other applications that require compliance with objects. The operational range of the sensor allows it to operate well with objects found in peoples' daily life. The fabrication of this sensor is simple and inexpensive because of its compact mechanical configuration and reduced electronics. These features are convenient for mass production of individual sensors as well as dense arrays. The biologically inspired tactile sensor is sensitive to both normal and lateral forces, providing better feedback to the host robot about the object to be grabbed. It has a high sensitivity, enabling its use in manipulation fingers, which typically have low mechanical impedance in order to be very compliant. The construction of the sensor is simple, using inexpensive technologies like silicon rubber molding and standard stock electronics.
Wroble, Julie; Frederick, Timothy; Frame, Alicia; Vallero, Daniel
2017-01-01
Established soil sampling methods for asbestos are inadequate to support risk assessment and risk-based decision making at Superfund sites due to difficulties in detecting asbestos at low concentrations and difficulty in extrapolating soil concentrations to air concentrations. Environmental Protection Agency (EPA)'s Office of Land and Emergency Management (OLEM) currently recommends the rigorous process of Activity Based Sampling (ABS) to characterize site exposures. The purpose of this study was to compare three soil analytical methods and two soil sampling methods to determine whether one method, or combination of methods, would yield more reliable soil asbestos data than other methods. Samples were collected using both traditional discrete ("grab") samples and incremental sampling methodology (ISM). Analyses were conducted using polarized light microscopy (PLM), transmission electron microscopy (TEM) methods or a combination of these two methods. Data show that the fluidized bed asbestos segregator (FBAS) followed by TEM analysis could detect asbestos at locations that were not detected using other analytical methods; however, this method exhibited high relative standard deviations, indicating the results may be more variable than other soil asbestos methods. The comparison of samples collected using ISM versus discrete techniques for asbestos resulted in no clear conclusions regarding preferred sampling method. However, analytical results for metals clearly showed that measured concentrations in ISM samples were less variable than discrete samples.
Characterizing Mineral Dust from the Arabian Coast of the Red Sea
NASA Astrophysics Data System (ADS)
Puthan Purakkal, J.; Stenchikov, G. L.; Engelbrecht, J. P.
2014-12-01
The Arabian Peninsula is one of the Earth's major sources of atmospheric dust. Along with profound negative effects on human activity and natural processes in this region, dust is an important nutrient source for the oligothrophic northern Red Sea. From preliminary observations it is estimated that some 18-20 major dust storms per year deposit about 6 Mt of mineral dust into the Red Sea. To better understand the optical properties, health, and ecological impacts of dust, we study the mineralogical, chemical and morphological properties of surface soil samples collected at prevbiously identified potential dust sources along the Arabian coast of the Red Sea. Many of these dust sources lie within a narrow coastal region and because of their proximity to the Red Sea, are important contributors to the dust/nutrient balance, during both dusty and fair weather conditions. Bulk samples were collected from the top 10 mm of soils from three sites along the Arabian coast of the Red Sea. The soil samples were sieved to separate the < 38μm particle fractions for chemical and mineralogical analysis. X-ray diffractometry (XRD) was applied to measure the mineral content of the dust. The chemical composition of individual particles was analyzed using scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDS). From the XRD analysis of the sieved samples from An Masayat (23.3322 N, 38.9481 E), Buthna (23.2960 N, 38.9384 E) and Rabugh pipeline Road (23.292 N, 38.91 E), it was found that the dust was composed largely of hematite, goethite, calcite, dolomite, quartz, chlorite, muscovite, amphibole, epidote and plagioclase. Our results are being compared to, and show similarities to those of Engelbrecht et al. , collected at 15 Middle East sites. Both the mineralogical content and chemical composition of samples bear the signatures of the regional geology. Engelbrecht, J. P., McDonald, E. V., Gillies, J. A., Jayanty, R. K. M., Casuccio, G., and Gertler, A. W., 2009, Characterizing mineral dusts and other aerosols from the Middle East - Part 2: Grab samples and re-suspensions: Inhalation Toxicology, v. 21, p. 327-336.
Older adult bathroom safety; Falls - bathroom safety ... You may need to have safety bars in your bathroom. These grab bars should be secured vertically or horizontally to the wall, not diagonally. DO NOT use ...
... First-Aid Kit Food Safety for Your Family Gun Safety Halloween Candy Hints Household Safety Checklists Household ... Climbing, and Grabbing Household Safety: Preventing Injuries From Firearms Household Safety: Preventing Injuries in the Crib Household ...
NASA Astrophysics Data System (ADS)
Maksimowicz, M.; Masarik, M. T.; Brandt, J.; Flores, A. N.
2017-12-01
Land use/land cover (LULC) change directly impacts the partitioning of surface mass and energy fluxes. Regional-scale weather and climate are potentially altered by LULC if the resultant changes in partitioning of surface energy fluxes are significant enough to induce changes in the evolution of the planetary boundary layer and its interaction with the atmosphere above. Dynamics of land use, particularly those related to the social dimensions of the Earth System, are often simplified or not represented in regional land-atmosphere models or Earth System Models. This study explores the role of LULC change on a regional hydroclimate system, focusing on potential hydroclimate changes arising from timber harvesting due to a land grab boom in Mozambique. We also focus more narrowly at quantifying regional impacts on Gorongosa National Park, a nationally important economic and biodiversity resource in southeastern Africa. After nationalizing all land in 1975 after Mozambique gained independence, complex social processes, including an extended low intensity conflict civil war and economic hardships, led to an escalation of land use rights grants to foreign governments. Between 2004 and 2009, large tracts of land were requested for timber. Here we use existing tree cover loss datasets to more accurately represent land cover within a regional weather model. LULC in a region encompassing Gorongosa is updated at three instances between 2001 and 2014 using a tree cover loss dataset. We use these derived LULC datasets to inform lower boundary conditions in the Weather Research and Forecasting (WRF) model. To quantify potential hydrometeorological changes arising from land use change, we performed a factorial-like experiment by mixing input LULC maps and atmospheric forcing data from before, during, and after the land grab. Results suggest that the land grab has impacted microclimate parameters in a significant way via direct and indirect impacts on land-atmosphere interactions. Results of this study suggest that LULC change arising from regional social dynamics are a potentially understudied, yet important human process to capture in both regional reanalyses and climate change projections.
The effect of phloretin on human γδ T cells killing colon cancer SW-1116 cells.
Zhu, Sheng-Ping; Liu, Gang; Wu, Xiao-Ting; Chen, Fu-Xing; Liu, Jun-Quan; Zhou, Zhong-Hai; Zhang, Jian-Fu; Fei, Su-Juan
2013-01-01
To explore the effect and mechanism of Phloretin on human γδ T cells killing colon cancer SW-1116 cells. γδ T cells were amplified in vitro from human peripheral blood mononuclear cells through isopentenyl pyrophosphate method (IPP). After cocultured different concentrations of Phloretin with γδ T cells or SW-1116 cells for 48h respectively, MTT assay was used to test the growth curve of these two cells; Flow cytometry to test the expression of Granzyme B (GraB), perforin (PFP), CD107a and IFN-γ of γδ T cells; Lactate dehydrogenase (LDH) release assay to test the cytotoxic activity of the γδ T cells on SW-1116 cells; and Western blot to test the Wnt3a expression of the γδ T cells. After cultured with IPP for ten days, the percentage of γδ T cells increased from 3.31±3.00% to 78.40±10.30%. Compared to the control group, when the concentration of Phloretin increased from 2.35μg/ml to 18.75μg/ml, it could significantly proliferate the γδ T cell growth (P<0.05) and inhibit the growth of SW-1116 cells in dose-response, and the expression of GraB, PFP, CD107a and Wnt3a significantly increased (P<0.05). Significant positive relationships were observed among CD107a and PFP, GraB, cytotoxicity (P<0.05). The percentage of IFN-γ producing γδ T cells treated with Phloretin was significantly higher than control group. Phloretin can enhance the killing effect of γδ T cells on SW-1116 cells; the mechanism may be that Phloretin could proliferate the γδ T cell growth, increase the expression of PFP and GraB, activate the Wnt signaling pathway, and produce higher level of IFN-γ. Indeed CD107a expression probably correlates quite well with antitumor activity. Copyright © 2012 Elsevier B.V. All rights reserved.
The Texas Thermal Interface: A real-time computer interface for an Inframetrics infrared camera
DOE Office of Scientific and Technical Information (OSTI.GOV)
Storek, D.J.; Gentle, K.W.
1996-03-01
The Texas Thermal Interface (TTI) offers an advantageous alternative to the conventional video path for computer analysis of infrared images from Inframetrics cameras. The TTI provides real-time computer data acquisition of 48 consecutive fields (version described here) with 8-bit pixels. The alternative requires time-consuming individual frame grabs from video tape with frequent loss of resolution in the D/A/D conversion. Within seconds after the event, the TTI temperature files may be viewed and processed to infer heat fluxes or other quantities as needed. The system cost is far less than commercial units which offer less capability. The system was developed formore » and is being used to measure heat fluxes to the plasma-facing components in a tokamak. {copyright} {ital 1996 American Institute of Physics.}« less
Brumbaugh, W.G.; Petty, J.D.; Huckins, J.N.; Manahan, S.E.
2002-01-01
A stabilized liquid membrane device (SLMD) is described for potential use as an in situ, passive, integrative sampler for cadmium (Cd), cobalt (Co), copper (Cu), nickel (Ni), lead (Pb), and zinc (Zn) in natural waters. The SLMD (patent pending) consists of a 2.5-cm-wide by 15-cm-long strip of low-density polyethylene (LDPE) layflat tubing containing 1 mL of an equal mixture (v/v) of oleic acid (cis-9-octadecenoic acid) and EMO-8Q (7-[4-ethyl-1-methyloctyl]-8-quinolinol). The reagent mixture continuously diffuses to the exterior surface of the LDPE membrane, and provides for sequestration of several divalent metals for up to several weeks. Depending on sampler configuration, concentration factors of several thousand can be realized for these metal ions after just a few days. In addition to in situ deployment, the SLMD may be useful for laboratory determination of labile metal species in grab samples. Methods for minimizing the effects of water flow on the sampling rate are currently under investigation.
Melcher, Anthony A; Horsburgh, Jeffery S
2017-06-01
Water quality in urban streams and stormwater systems is highly dynamic, both spatially and temporally, and can change drastically during storm events. Infrequent grab samples commonly collected for estimating pollutant loadings are insufficient to characterize water quality in many urban water systems. In situ water quality measurements are being used as surrogates for continuous pollutant load estimates; however, relatively few studies have tested the validity of surrogate indicators in urban stormwater conveyances. In this paper, we describe an observatory aimed at demonstrating the infrastructure required for surrogate monitoring in urban water systems and for capturing the dynamic behavior of stormwater-driven pollutant loads. We describe the instrumentation of multiple, autonomous water quality and quantity monitoring sites within an urban observatory. We also describe smart and adaptive sampling procedures implemented to improve data collection for developing surrogate relationships and for capturing the temporal and spatial variability of pollutant loading events in urban watersheds. Results show that the observatory is able to capture short-duration storm events within multiple catchments and, through inter-site communication, sampling efforts can be synchronized across multiple monitoring sites.
NASA Astrophysics Data System (ADS)
Widianingsih, W.; Zaenuri, M.; Anggoro, S.; Kusumaningrum, H. P.; Hartati, R.
2018-03-01
The study of characteristic sediment and water column chlorophyll-a has an important role in the sea cucumber habitat. Sediment chlorophyll-a represents a productivity primer for the benthic community. This research has a purpose to investigate characteristic sediment and water column chlorophyll-a on the Kenjeran water, Surabaya. Sediment samples were collected by the ekman grab for analysis, grain size and nutrient. The sample for sediment chlorophyll-a was taken by core sampler. The water samples were taken with Nansen Bottles. According to the research result, the values of sediment chlorophyll-a at station 10, 11 and 12 were higher than the other stations. In contrast, the value of chlorophyll-a in the column water had almost the same value for each station. The sediment chlorophyll-a value on clay and silt sediment type was higher than the fine sand and coarse sediment type. The suitable habitat characteristic for Paracaudina sp. was clay and silt sediment with sediment chlorophyll concentration ranging from 347.82 mg·m-2 to 1135.52 mg·m-2.
Blanchard, Robert A.; Wagner, Daniel M.; Evans, Dennis A.
2010-01-01
In February 2010, the U.S. Geological Survey, in cooperation with the U.S. Army Corps of Engineers, Memphis District, investigated the presence of inorganic elements and organic compounds in bed sediments of the lower Mississippi River. Selected sites were located in the navigation channel near river miles 737, 773, and 790 near Memphis, Tennessee. Bed-sediment samples were collected using a Shipek grab sampler mounted to a boom crane with a motorized winch. Samples then were processed and shipped to the U.S. Geological Survey Sediment Laboratory in Rolla, Missouri, the USGS National Water Quality Laboratory in Denver, Colorado, and to TestAmerica Laboratory, Inc. in West Sacramento, California. Samples were analyzed for grain size, inorganic elements (including mercury), and organic compounds. Chemical results were tabulated and listed with sediment-quality guidelines and presented with the physical property results. All of the bed material samples collected during this investigation yielded concentrations that were less than the Consensus-Based Probable Effect Concentration guidelines. The physical properties were tabulated and listed using a standard U.S. Geological Survey scale of sizes by class for sediment analysis. All of the samples collected during this investigation indicated a percent composition mostly comprised of sand, ranging from less than 0.125 millimeters to less than 2 millimeters.
46 CFR 169.685 - Electric heating and cooking equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SCHOOL VESSELS Machinery and Electrical Electrical Installations Operating at Potentials of 50 Volts Or... spillage on wiring or the deck. (f) Where necessary for safety of personnel, grab rails must be provided...
Nature of migrabitumen and their relation to regional thermal maturity, Ouachita Mountains, Oklahoma
Cardott, Brian J.; Ruble, Tim E.; Suneson, Neil H.
1993-01-01
Two grahamite and three impsonite localities are within an 82-km-long segment of the Ouachita Mountains of southeastern Oklahoma. Grab samples were collected to study the petrographic and geochemical characteristics of the migrabitumen at the grahamite-impsonite transition and the relation of the migrabitumen to the regional thermal maturity pattern. Maximum and random bitumen reflectance values increased from 0.75 to 1.80% from west to east, consistent with the regional thermal maturation trend. Mean bireflectance values increased from 0.04 to 0.38%. The two grahamite samples are classified at the grahamite-impsonite boundary with conflicting petrographic (bitumen reflectance) and bulk chemical (volatile matter) maturity indicators. The regional maturation trend, based on vitrinite reflectance and bitumen reflectance values, was confirmed by a detailed geochemical investigation of bitumen extracts. Although biomarker analyses were influenced by extensive biodegradation effects, molecular parameters based on the phenanthrenes, dibenzothiophenes, and tricyclic terpanes were identified as useful maturity indicators.
Miller, Rachael Z; Watts, Andrew J R; Winslow, Brooke O; Galloway, Tamara S; Barrows, Abigail P W
2017-11-15
Aquatic environments are sinks for anthropogenic contamination, whether chemical or solid pollutants. Microfibers shed from clothing and other textiles contribute to this problem. These can be plastic or non-plastic origin. Our aim was to investigate the presence and distribution of both types of anthropogenic microfibers along the length of the Hudson River, USA. Surface grab samples were collected and filtered through a 0.45μm filter paper. Abundance of fibers was determined after subtraction of potential contamination. 233 microfibers were recorded in 142 samples, averaging 0.98microfibersL -1 . Subsequent micro-FTIR showed half of the fibers were plastic while the other half were non-plastic, but of anthropogenic origin. There was no relationship between fiber abundance, wastewater treatment plant location or population density. Extrapolating from this data, and using available hydrographic data, 34.4% of the Hudson River's watershed drainage area contributes an average 300 million anthropogenic microfibers into the Atlantic Ocean per day. Copyright © 2017 Elsevier Ltd. All rights reserved.
A mobile water analysis laboratory for the study of stream nutrient and DOC dynamics
NASA Astrophysics Data System (ADS)
Echevarria Roman, Y.; Pullin, M. J.; Schwingle, R.; Gabrielsen, P. J.
2013-12-01
The dynamics of nutrient and dissolved organic carbon (DOC) quantity and composition in streams vary with season and in response to hydrologic events. Periodic grab sampling can capture some of this variation, but has also been shown to miss high flow events. Sampling during winter, during thunderstorms, and at night is difficult and sometimes hazardous. For these reasons, we have developed a mobile laboratory that autonomously determines pH, Eh, conductivity, dissolved oxygen, turbidity, nitrate, phosphate, DOC, DIC, as well as DOC fluorescence and absorbance continuously on a minutes timescale. The laboratory includes a Labview operated computer system that allows remote control and interaction with pumps, pressure, temperature, and flow sensors as well as the analytical instruments. Climate control allows for operation in winter. The design and operation of this laboratory will be presented. We will also discuss example data showing diurnal changes and responses to hydrologic events in DOC quantity and quality in the East Fork of the Jemez River, New Mexico.
Pitacco, Valentina; Lipej, Lovrenc; Mavrič, Borut; Mistri, Michele; Munari, Cristina
2018-04-01
Benthic indicators are important tools for the classification of coastal and transitional water bodies. The aim of the work was to assess for the first time the Environmental Status (ES) of Slovenian transitional waters, comparing the following biotic indices: richness, Shannon-Weaver diversity, AMBI, M-AMBI, BENTIX and BITS indices. A total of 13 stations were sampled with a Van Veen grab, in three ecosystems in the northern Adriatic. Samples were sieved and sorted, invertebrates identified and counted. The anthropogenic impact was estimated with professional judgement. Richness and diversity showed a good response to anthropogenic pressure. Conversely, indices based on sensitivity/tolerance groups did not showed a clear distinction between more and less impacted ecosystems. In particular BENTIX underestimated the ES, while with BITS there was a overestimation. The best evaluation was obtained with M-AMBI, because even if based on a sensitivity/tolerance approach, it considered also the structural aspect of the community. Copyright © 2017 Elsevier Ltd. All rights reserved.
Measurements of Volatile Organic Compounds in Beijing, China, in August 2005
NASA Astrophysics Data System (ADS)
Kuster, W. C.; Shao, M.; Goldan, P. D.; Liu, Y.; Li, X.; Roberts, J. M.; Zhang, J.; Bin, W.; Degouw, J.
2005-12-01
The emissions of trace gases and aerosol in Mega-cities and the subsequent photochemical processing are of great current interest in developing pollution control strategies but there is still a significant lack of data from many large urban centers. From August 1 through August 27, 2005, a measurement campaign was carried out on the Peking University campus in Beijing, China. This period included extended episodes with high temperatures, high humidity and extremely poor air quality as well as episodes with cooler, clear dry air. As part of this campaign, a wide range of VOCs and oxygenated VOCs were measured by an online GC-MS system. Results of those measurements, as well as comparisons with ambient air grab samples analyzed by the Peking University canister-sampling program, will be presented. Hydrocarbon emission profiles will be compared with those from an average city in the U.S. In addition we will look at the formation of secondary species such as oxygenated VOCs and peroxyacyl nitrates.
Vallet-Coulomb, Christine; Cartapanis, Olivier; Radakovitch, Olivier; Sonzogni, Corinne; Pichaud, Marc
2010-03-01
A continuous record of atmospheric vapour isotopic composition (delta(A)) can be derived from the isotope mass balance of a water body submitted to natural evaporation. In this paper, we present preliminary results of the application of this method to a drying evaporation pan, located in a Mediterranean wetland, during a two-month summer period. Results seem consistent with few atmospheric vapour data based on the assumption of isotopic equilibrium with precipitation, but we observed a shift between pan-derived delta(A) and the composition of vapour samples collected by cold trapping. These results suggest that further investigations are necessary to evaluate the effect of diurnal variations of atmospheric conditions on the applicability of the pan-evaporation method, and on the representative of grab atmospheric samples. We also propose a sensitivity analysis for evaluating the impact of the different measured components on delta(A) calculation, and show an improvement in the method efficiency as the pan is drying.
Healthy Breakfast: Quick, Flexible Options to Grab at Home
... dairy. Examples include milk, plain or lower sugar yogurts, and low-fat cheeses, such as cottage cheese ... of fruit, a container of milk or some yogurt. A word about cereal bars Cereal bars may ...
Castellanos, E H; Charboneau, E; Dietrich, M S; Park, S; Bradley, B P; Mogg, K; Cowan, R L
2009-09-01
The major aim of this study was to investigate whether the motivational salience of food cues (as reflected by their attention-grabbing properties) differs between obese and normal-weight subjects in a manner consistent with altered reward system function in obesity. A total of 18 obese and 18 normal-weight, otherwise healthy, adult women between the ages of 18 and 35 participated in an eye-tracking paradigm in combination with a visual probe task. Eye movements and reaction time to food and non-food images were recorded during both fasted and fed conditions in a counterbalanced design. Eating behavior and hunger level were assessed by self-report measures. Obese individuals had higher scores than normal-weight individuals on self-report measures of responsiveness to external food cues and vulnerability to disruptions in control of eating behavior. Both obese and normal-weight individuals demonstrated increased gaze duration for food compared to non-food images in the fasted condition. In the fed condition, however, despite reduced hunger in both groups, obese individuals maintained the increased attention to food images, whereas normal-weight individuals had similar gaze duration for food and non-food images. Additionally, obese individuals had preferential orienting toward food images at the onset of each image. Obese and normal-weight individuals did not differ in reaction time measures in the fasted or fed condition. Food cue incentive salience is elevated equally in normal-weight and obese individuals during fasting. Obese individuals retain incentive salience for food cues despite feeding and decreased self-report of hunger. Sensitization to food cues in the environment and their dysregulation in obese individuals may play a role in the development and/or maintenance of obesity.
LANDSAT detection of hydrothermal alteration in the Nogal Canyon Cauldron, New Mexico
NASA Technical Reports Server (NTRS)
Vincent, R. K.; Rouse, G.
1977-01-01
In 1974 a circular-shaped iron oxide anomaly was observed in an image of a LANDSAT frame centered near Truth or Consequences, New Mexico. Field examination of the anomaly has shown that it coincides with a zone of hydrothermal alteration on the northern edge of the Nogal Canyon Cauldron. The altered area contains clay minerals ranging in colors from white to vivid red, the latter presumably resulting from hematite staining. In situ gas measurements showed no evidence of active hydrogen sulfide seepage. Preliminary geochemical analyses of grab samples have detected no significant amounts of mineralization. Whereas this area does not at present appear to be economically important, it provides an example of how LANDSAT can be utilized in reconnaissance mapping for cauldrons, calderas, and other volcanic features which display hydrothermal alteration.
Wildhaber, M.L.; Schmitt, C.J.
1998-01-01
We evaluated the toxic-units model developed by Wildhaber and Schmitt (1996) as a predictor of indices of mean tolerance to pollution (i.e., Lenat, 1993; Hilsenhoff, 1987) and other benthic community indices from Great Lakes sediments containing complex mixtures of environmental contaminants (e.g., polychlorinated biphenyls – PCBs, polycyclic aromatic hydrocarbons – PAHs, pesticides, chlorinated dioxins, and metals). Sediment toxic units were defined as the ratio of the estimated pore-water concentration of a contaminant to its chronic toxicity as estimated by U.S. Environmental Protection Agency Ambient Water Quality Criteria (AWQC) or other applicable standard. The total hazard of a sediment to aquatic life was assessed by summing toxic units for all contaminants quantified. Among the benthic community metrics evaluated, total toxic units were most closely correlated with Lenat's (1993) and Hilsenhoff's (1987) indices of community tolerance (TL and TH, respectively); toxic units accounted for 42% TL and 53% TH of variability in community tolerance as measured by Ponar grabs. In contrast, taxonomic richness and Shannon-Wiener diversity were not correlated (P > 0.05) with toxic units. Substitution of order- or family-level identifications for lowest possible (mostly genus- or species-) level identifications in the calculation of TL and TH indices weakened the relationships with toxic units. Tolerance values based on order- and family-level identifications of benthos for artificial substrate samples were more strongly correlated with toxic units than tolerance values for benthos from Ponar grabs. The ability of the toxic-units model to predict the other two components (i.e., laboratory-measured sediment toxicity and benthic community composition) of the Sediment Quality Triad (SQT) may obviate the need for the SQT in some situations.
Presley, Todd K.; Jamison, Marcael T.J.
2010-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff collected by the H-1 storm drain on the Manoa-Palolo Drainage Canal. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2009, and June 30, 2010. As part of this program, rainfall and continuous discharge data were collected at the H-1 storm drain. During the year, sampling strategy and sample processing methods were modified to improve the characterization of the effects of discharge from the storm drain on the Manoa-Palolo Drainage Canal. During July 1, 2009, to February 1, 2010, samples were collected from only the H-1 storm drain. Beginning February 2, 2010, samples were collected simultaneously from the H-1 storm drain and the Manoa-Palolo Drainage Canal at a location about 50 feet upstream of the discharge point of the H-1 storm drain. Three storms were sampled during July 1, 2009, to June 30, 2010. All samples were collected using automatic samplers. For the storm of August 12, 2009, grab samples (for oil and grease, and total petroleum hydrocarbons) and a composite sample were collected. The composite sample was analyzed for total suspended solids, nutrients, and selected dissolved and total (filtered and unfiltered) trace metals (cadmium, chromium, nickel, copper, lead, and zinc). Two storms were sampled in March 2010 at the H-1 storm drain and from the Manoa-Palolo Drainage Canal. Two samples were collected during the storm of March 4, 2010, and six samples were collected during the storm of March 8, 2010. These two storms were sampled using the modified strategy, in which discrete samples from the automatic sampler were processed and analyzed individually, rather than as a composite sample, using the simultaneously collected samples from the H-1 storm drain and from the Manoa-Palolo Drainage Canal. The discrete samples were analyzed for some or all of the following constituents: total suspended solids, nutrients, oil and grease, and selected dissolved (filtered) trace metals (cadmium, chromium, nickel, copper, lead, and zinc). Five quality-assurance/quality-control samples were analyzed during the year. These samples included one laboratory-duplicate, one field-duplicate, and one matrix-spike sample prepared and analyzed with the storm samples. In addition, two inorganic blank-water samples, one sample at the H-1 storm drain and one sample at the Manoa-Palolo Drainage Canal, were collected by running the blank water (water purified of all inorganic constituents) through the sampling and processing systems after cleaning automatic sampler lines to verify that the sampling lines were not contaminated.
U.S. Geological Survey Catskill/Delaware Water-Quality Network: Water-Quality Report Water Year 2006
McHale, Michael R.; Siemion, Jason
2010-01-01
The U.S. Geological Survey operates a 60-station streamgaging network in the New York City Catskill/Delaware Water Supply System. Water-quality samples were collected at 13 of the stations in the Catskill/Delaware streamgaging network to provide resource managers with water-quality and water-quantity data from the water-supply system that supplies about 85 percent of the water needed by the more than 9 million residents of New York City. This report summarizes water-quality data collected at those 13 stations plus one additional station operated as a part of the U.S. Environmental Protection Agency's Regional Long-Term Monitoring Network for the 2006 water year (October 1, 2005 to September 30, 2006). An average of 62 water-quality samples were collected at each station during the 2006 water year, including grab samples collected every other week and storm samples collected with automated samplers. On average, 8 storms were sampled at each station during the 2006 water year. The 2006 calendar year was the second warmest on record and the summer of 2006 was the wettest on record for the northeastern United States. A large storm on June 26-28, 2006, caused extensive flooding in the western part of the network where record peak flows were measured at several watersheds.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hathcock, Charles Dean
The proposed action being assessed in this document occurs in TA-02 in the bottom of Los Alamos Canyon. The DOE proposes to conduct soil sampling at AOC 02-011 (d), AOC 02- 011(a)(ii), and SWMU 02-005, and excavate soils in AOC 02-011(a)(ii) as part of a corrective actions effort. Additional shallow surface soil samples (soil grab samples) will be collected throughout the TA-02 area, including within the floodplain, to perform ecotoxicology studies (Figures 1 and 2). The excavation boundaries in AOC 02-011(a)(ii) are slightly within the delineated 100-year floodplain. The project will use a variety of techniques for soil sampling andmore » remediation efforts to include hand/digging, standard hand auger/sampling, excavation using machinery such as backhoe and front end loader and small drill rig. Heavy equipment will traverse the floodplain and spoils piles will be staged in the floodplain within developed or previously disturbed areas (e.g., existing paved roads and parking areas). The project will utilize and maintain appropriate best management practices (BMPs) to contain excavated materials, and all pollutants, including oil from machinery/vehicles. The project will stabilize disturbed areas as appropriate at the end of the project.« less
Assistive Devices: MedlinePlus Health Topic
... dressed. Some are high-tech tools, such as computers. Others are much simpler, like a "reacher" - a tool that helps you grab an object you can't reach. Learn More ... For What Conditions Are Assistive Devices Used? (National ...
Is ostension any more than attention?
Szufnarowska, Joanna; Rohlfing, Katharina J; Fawcett, Christine; Gredebäck, Gustaf
2014-06-16
According to natural pedagogy theory, infants are sensitive to particular ostensive cues that communicate to them that they are being addressed and that they can expect to learn referential information. We demonstrate that 6-month-old infants follow others' gaze direction in situations that are highly attention-grabbing. This occurs irrespective of whether these situations include communicative intent and ostensive cues (a model looks directly into the child's eyes prior to shifting gaze to an object) or not (a model shivers while looking down prior to shifting gaze to an object). In contrast, in less attention-grabbing contexts in which the model simply looks down prior to shifting gaze to an object, no effect is found. These findings demonstrate that one of the central pillars of natural pedagogy is false. Sensitivity to gaze following in infancy is not restricted to contexts in which ostensive cues are conveyed.
Influence of two catching methods on the occurrence of lesions in broilers.
Langkabel, Nina; Baumann, Maximilian P O; Feiler, Annika; Sanguankiat, Arsooth; Fries, Reinhard
2015-08-01
During the catching of broilers for slaughter, 2 to 3 birds are grabbed per hand at one leg at the same time. From an animal welfare point of view, this procedure is under critical observation from animal welfare administration and the general public.In this paper 2 catching methods were compared: the routinely used 1-leg catching method, and a second tech-nique whereby birds were grabbed by both legs with a maximum of 2 birds per hand (2-leg catching method). Lesions on the body, legs, and wings (hemorrhages and fractures) were recorded by a camera system located after the plucking position. Two weight classes, 2 catching teams, and 2 flocks were included in the study.Heavy animals showed more lesions than birds of the light weight class. In all investigations, lesions on the body and legs were rare, whereas wing lesions occurred at a rate of up to 15.32%. Statistical analysis showed no significant difference between the 2 methods or between the catching teams for both weight classes. A correlation between lesions and weight was observed, with a significant odds ratio ( OR: ) of 3.6 (95% CI: 3.299-3.957).During 2-leg catching, the animals appeared to be more restless. Workers stated that the grabbing of both legs of a bird was more difficult and that working in a crouching position for a longer time was harder.We conclude that the cautious handling of animals to reduce stress is more important than "holding animals by both legs", as has been proposed. © 2015 Poultry Science Association Inc.
NASA Astrophysics Data System (ADS)
Gaida, T. C.; Snellen, M.; van Dijk, T. A. G. P.; Simons, D. G.
2017-12-01
Coastal erosion induced by natural processes, such as wind, waves, tidal currents, or human interferences endangers human beings, infrastructure, fauna and flora at the oceans and rivers all over the world. In The Netherlands, in particular the North Sea islands are strongly affected by sediment erosion. To protect and stabilize the coastline, beach and shoreface nourishments are frequently performed. Thereby, sediment reservoirs are created that replace the eroded sediments. Increasing the long-term efficiency of coastal protection requires monitoring of the temporal and spatial development of the coastal nourishments. Multi-beam echo-sounders (MBES) allow for detailed and comprehensive investigations of the seabed composition and structure. To investigate the potential of using MBES for monitoring nourishments in a tidal inlet, four MBES surveys per year are carried out at the Dutch Wadden island Ameland. A pre-nourishment MBES survey was performed in April 2017 and the subsequent post-nourishment survey will take place in September 2017. Both surveys are equipped with a Kongsberg EM 2040C dual-head MBES and are supported with extensive grab sampling. In this study the use of MBES backscatter and bathymetry data are considered as an approach for monitoring coastal nourishments. The aim is to develop a monitoring procedure that allows for comparing MBES data taken during different surveys, i.e., with variations in environmental conditions, MBES characteristics and acquisition procedures. Different unsupervised and supervised acoustic seafloor classification techniques are applied to the processed MBES data to classify the seabed sediments. The analysis of the pre-nourishment MBES data indicates that the backscatter and consequently the classification are highly driven by the abundancy of shell fragments. These results will be used as a baseline to investigate the accumulation of the underwater nourishments. Independent grab samples will be used to select the optimal method for monitoring the development of underwater nourishments. This work will contribute to conventional and also to modern coastal protection strategies, e.g. using nature-based solutions, where natural processes (tides, waves) are used to redistribute coastal nourishments.
... from rubbing can scrape or tear the person's skin. Common areas at risk for friction are the shoulders, back, buttocks, elbows, and heels. Never move patients up by grabbing them under their arms and pulling. This can injure their shoulders.
5 Ways to Avoid Filling Up on Empty Calories
It's easy to get overwhelmed by our busy lives and grab food on the go that doesn’t provide the nourishment our bodies need. Pretty much anything you would call “junk food” is an empty-calorie culprit.
Effect-related monitoring: estrogen-like substances in groundwater.
Kuch, Bertram; Kern, Frieder; Metzger, Jörg W; von der Trenck, Karl Theo
2010-02-01
Concentration monitoring as a basis for risk assessment is a valid approach only if there is an unambiguous relation between concentration and effect. In many cases, no such unambiguous relation exists, since various substances can exert the same effect with differing potencies. If some or all of these substances contributing to a biological effect are unknown, effect-related monitoring becomes indispensable. Endocrine-disrupting substances in water bodies, including the groundwater, are a prominent example of such a case. The aim of the investigations described here was to detect hormonally active substances in the groundwater downstream of obsolete landfills by using the E-screen assay and to possibly assign the biological effect to individual chemical compounds by means of instrumental analyses carried out in parallel. Grab samples of the groundwater were collected downstream from abandoned landfills and prepared by liquid/liquid extraction. The total estrogenic activity in these samples was determined in vitro by applying the E-screen assay. The human breast cancer cells (MCF-7) used in the E-screen proliferate in response to the presence of estrogenically active compounds. Expressed in concentration units of the reference substance 17beta-estradiol (E2), the test system allows the quantification of estrogenicity with a limit of detection (LOD) in the range of 0.1 ng/L. Aliquots of the samples were screened using gas chromatography/mass spectrometry (GC/MS) in order to quantify known estrogenically active substances and to identify unknown compounds. Estrogen-positive samples were extracted at different pH values, split into acidic, neutral, and basic fractions and analyzed by GC/MS, searching for individual components that display estrogenic activity. Estrogenic activity exceeding the LOD and the provisional benchmark of 0.5 ng E2/L was found at three out of seven abandoned waste disposal sites tested. The low concentrations of known xenoestrogens such as bisphenol-A, nonylphenols, or phthalic acid esters determined by GC/MS, however, were not sufficient to explain the detected activity. Neither natural nor synthetic hormones have caused the activity because these chemical structures are readily degradable and cannot persist in abandoned landfills for decades. The highest activity in the E-screen assay was found in the acidic fractions. Hydroxypolychlorinated biphenyls (PCBs), hydroxylated polycyclic aromatic hydrocarbons (PAHs) and hetero-PAHs, as well as alkylphenols could be identified as further compounds with possible hormonal activity. Estrogenically active substances may occur in the groundwater below obsolete landfills, especially those that contain PCBs or waste from gasworks. These substances are not part of analytical programs routinely applied to contaminated sites and may therefore escape detection and assessment. Analyses using the E-screen assay and GC/MS in parallel have shown that the total estrogenic activity found in groundwater samples is to be ascribed to a multitude of individual compounds, some of which cannot be quantified due to lack of standard substances or assessed due to lack of a standardized procedure for determination of their estrogenic potency. By comparison with provisional guide values for estradiol (0.5 ng/L) and ethynylestradiol (0.3 ng/L), the damaging potential of the total estrogenic activity in groundwater samples can in fact be assessed, but specific remediation measures are impossible unless the hormonal activity can be attributed to individual chemical substances. On the one hand, further analyses of samples taken from possible pollution sources should be conducted in order to characterize the extent of groundwater pollution with xenoestrogens. On the other hand, the most potent individual compounds should be identified according to their estrogenic potency. To this end, bioassay-directed fractionation and structure elucidation should be carried out with concentrated samples.
In-Situ Ion Analysis of Fresh Waters via an ISE Multiprobe and Artificial Neural Networks
NASA Astrophysics Data System (ADS)
Mueller, A. V.; Hemond, H.
2010-12-01
The ecological and geochemical sciences stand to substantially gain from capability for comprehensive, real-time, in-situ characterization of the chemical constituents of natural waters, e.g. by facilitating rapid high-resolution adaptive sampling campaigns and avoiding the potential errors and high costs related to traditional grab sample collection, transportation and in-lab analysis. In-situ chemical instrumentation also promotes the goals of large-scale monitoring networks, such as CUASHI and WATERS, by reducing the financial and human resources overhead required for traditional sampling at this scale. Problems of environmental remediation and monitoring of industrial waste waters would additionally benefit from such instrumental capacity. We have pursued in-situ measurement of all major ions contributing to the charge makeup (>99%) of oxic natural fresh waters via an instrument combining an array of ion-selective electrode (ISE) hardware with an appropriate multivariate signal processing architecture. Commercially available electrochemical sensors promote low cost and a fast development schedule, as well as easy maintenance and reproduction. Data processing techniques are adapted from artificial intelligence and chemometrics to extract accurate information from the corresponding in-situ data matrix. This architecture takes into account temperature, conductivity, and non-linearity effects, as well as taking advantage of sensor cross-selectivities traditionally considered as interferences. Chemical and mathematical constraints, e.g. charge balance and total ionic strength, provide further system-level information. Maximizing data recovery from the sensor array allows use of the instrument without the standard additions or ionic strength adjustment traditionally-required with use of ISEs. Initial work demonstrates the effectiveness of this methodology at predicting inorganic cations (sodium, potassium, calcium, and ammonium ) and hydrogen ion in a simplified system containing only a single non-hydroxide anion (chloride), thus allowing charge neutrality to be easily and explicitly invoked. An array of 9 ISEs are calibrated relative to the seven ions of interest, and resulting curves are used to create a representative environmental data set based on historical USGS data for New England waters. Applicability of the developed signal processing methodology is demonstrated, including use of an extended feedback architecture based on conductivity measurements and charge neutrality calculations, with algorithms tuned to optimize performance when predicting actual concentrations from these simulated signals. Results are compared to use of component probes as stand-alone sensors. Future extension of this instrument for multiple anions (including carbonate/bicarbonate, nitrate, and sulfate) will ultimately provide rapid, accurate field measurements of the entire charge balance of natural waters at high resolution, improving sampling abilities while reducing costs and errors related to transport and analysis of grab samples.
NASA Astrophysics Data System (ADS)
Mueller, A. V.; Hemond, H.
2009-12-01
The capability for comprehensive, real-time, in-situ characterization of the chemical constituents of natural waters is a powerful tool for the advancement of the ecological and geochemical sciences, e.g. by facilitating rapid high-resolution adaptive sampling campaigns and avoiding the potential errors and high costs related to traditional grab sample collection, transportation and analysis. Portable field-ready instrumentation also promotes the goals of large-scale monitoring networks, such as CUASHI and WATERS, without the financial and human resources overhead required for traditional sampling at this scale. Problems of environmental remediation and monitoring of industrial waste waters would additionally benefit from such instrumental capacity. In-situ measurement of all major ions contributing to the charge makeup of natural fresh water is thus pursued via a combined multi-sensor/multivariate signal processing architecture. The instrument is based primarily on commercial electrochemical sensors, e.g. ion selective electrodes (ISEs) and ion selective field-effect transistors (ISFETs), to promote low cost as well as easy maintenance and reproduction,. The system employs a novel architecture of multivariate signal processing to extract accurate information from in-situ data streams via an "unmixing" process that accounts for sensor non-linearities at low concentrations, as well as sensor cross-reactivities. Conductivity, charge neutrality and temperature are applied as additional mathematical constraints on the chemical state of the system. Including such non-ionic information assists in obtaining accurate and useful calibrations even in the non-linear portion of the sensor response curves, and measurements can be made without the traditionally-required standard additions or ionic strength adjustment. Initial work demonstrates the effectiveness of this methodology at predicting inorganic cations (Na+, NH4+, H+, Ca2+, and K+) in a simplified system containing only a single anion (Cl-) in addition to hydroxide, thus allowing charge neutrality to be easily and explicitly invoked. Calibration of every probe relative to each of the five cations present is undertaken, and resulting curves are used to create a representative environmental data set based on USGS data for New England waters. Signal processing methodologies, specifically artificial neural networks (ANNs), are extended to use a feedback architecture based on conductivity measurements and charge neutrality calculations. The algorithms are then tuned to optimize performance of the algorithm at predicting actual concentrations from these simulated signals. Results are compared to use of component probes as stand-alone sensors. Future extension of this instrument for multiple anions (including carbonate and bicarbonate, nitrate, and sulfate) will ultimately provide rapid, accurate field measurements of the entire charge balance of natural waters at high resolution, improving sampling abilities while reducing costs and errors related to transport and analysis of grab samples.
Scudder Eikenberry, Barbara C.; Bell, Amanda H.; Burns, Daniel J.; Olds, Hayley T.
2014-01-01
Four river systems on the Wisconsin shoreline of Lake Michigan are designated Areas of Concern (AOCs) because of severe environmental degradation: the Lower Menominee River, Lower Green Bay and Fox River, Sheboygan River, and Milwaukee Estuary. Each AOC has one or more Beneficial Use Impairments (BUIs) that form the basis of the AOC designation and that must be remediated or otherwise addressed before the AOC designation can be removed. All four of these AOCs have BUIs for benthos (bottom-dwelling or benthic invertebrates), and all but the Menominee River have a BUI for plankton (free-floating algae and invertebrates, or phytoplankton and zooplankton, respectively). The U.S. Geological Survey collected samples in 2012 at these four AOCs and at six non-AOCs to support the evaluation of the status of aquatic communities in the benthos and plankton at the AOCs. Samples were collected during three periods representing spring, summer, and fall. Benthos samples were collected using a dredge grab sampler and artificial substrates; plankton samples were collected using a tow net for zooplankton and a vertical water sampler for phytoplankton. Benthos and plankton were identified to the lowest possible taxonomic category and counted; samples for documenting water temperature, pH, and specific conductance, as well as sediment particle size and organic carbon were also collected during biological sampling.
Volkmar, E.C.; Dahlgren, R.A.; Stringfellow, W.T.; Henson, S.S.; Borglin, S.E.; Kendall, C.; Van Nieuwenhuyse, E. E.
2011-01-01
To investigate the mechanism for diel (24h) changes commonly observed at fixed sampling locations and how these diel changes relate to downstream transport in hypereutrophic surface waters, we studied a parcel of agricultural drainage water as it traveled for 84h in a concrete-lined channel having no additional water inputs or outputs. Algal fluorescence, dissolved oxygen, temperature, pH, conductivity, and turbidity were measured every 30min. Grab samples were collected every 2h for water quality analyses, including nutrients, suspended sediment, and chlorophyll/pheophytin. Strong diel patterns were observed for dissolved oxygen, pH, and temperature within the parcel of water. In contrast, algal pigments and nitrate did not exhibit diel patterns within the parcel of water, but did exhibit strong diel patterns for samples collected at a fixed sampling location. The diel patterns observed at fixed sampling locations for these constituents can be attributed to algal growth during the day and downstream transport (washout) of algae at night. Algal pigments showed a rapid daytime increase during the first 48h followed by a general decrease for the remainder of the study, possibly due to sedimentation and photobleaching. Algal growth (primarily diatoms) was apparent each day during the study, as measured by increasing dissolved oxygen concentrations, despite low phosphate concentrations (<0.01mgL-1). ?? 2011 Elsevier B.V.
Determination of phenolic priority pollutants utilizing permeation sampling method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Guozheng.
1990-01-01
A passive permeation sampling method for the determination of phenolic priority pollutants in water was developed. Phenols in an aqueous solution permeate a polymeric membrane and are collected on a solid adsorbent in a sampling device. Both solvent and thermal desorption techniques were employed to recovery phenolic pollutants collected. In the solvent desorption, phenolic compounds collected on the XAD-7 resin, and then desorbed by acetonitrile. In the thermal desorption, phenolic compounds collected on Tenax-TA were recovered thermally, Separation and quantification is achieved by a SPB-5 capillary column gas chromatography using a flame ionization detector. There are linear relationships between themore » amount of phenolic compounds collected and the products of the exposure times and concentrations over the range from 5 ppb to 20 ppm with precisions no worse than 13%. The permeation rates of the phenolic pollutants depend upon the exposure temperature, solution pH and membrane area. Samples collected can be stored for up to two weeks without loss. This method provides a simple, convenient and inexpensive way for monitoring the time-weighted-average concentration without the use of a pumping system. An automated sampler which combines the permeation and the thermal desorption techniques together was also developed for water sample obtained from grab sampling. The on-line setup provides a high degree of automation. Detection limits at 10 ppb can be achieved using this sampler.« less
Dunford: Narrative, Momentum in Anti-ISIL Fight Has Shifted to Iraqis >
was really low." As recently as May 2015, the terror group was still grabbing ground from Iraq forces are having successes against the terror group. They are also applying pressure against the group
Effect of urban stormwater runoff on ground water beneath recharge basins on Long Island, New York
Ku, H.F.; Simmons, D.L.
1986-01-01
Urban stormwater runoff was monitored during 1980-82 to investigate the source, type, quantity, and fate of contaminants routed to the more than 3,000 recharge basins on Long Island and to determine whether this runoff might be a significant source of contamination to the groundwater reservoir. Forty-six storms were monitored at five recharge basins in representative land use areas (strip commercial, shopping-mall parking lot, major highway, low-density residential, and medium-density residential). Runoff:precipitation ratios indicate that all storm runoff is derived from precipitation on impervious surfaces in the drainage area, except during storms of high intensity or long duration, when additional runoff can be derived from precipitation on permeable surfaces. Lead was present in highway runoff in concentrations up to 3300 micrograms/L, and chloride was found in parking lot runoff concentrations up to 1,100 mg/L during winter, when salt is used for deicing. In the five composite stormwater samples and nine groundwater grab samples that were analyzed for 113 EPA-designated ' priority pollutants, ' four constituents were detected in concentrations exceeding New York State guidelines of 50 micrograms/L for an individual organic compound in drinking water: p-chloro-m-cresol (79 micrograms/L); 2 ,4-dimethylphenol (96 micrograms/L); 4-nitrophenol (58 micrograms/L); and methylene chloride (230 micrograms/L in either groundwater or stormwater at the highway basin). One stormwater sample and two groundwater samples exceeded New York State guidelines for total organic compounds in drinking water (100 micrograms/L). The presence of these constituents is attributed to contamination from point sources rather than to the quality of runoff from urban areas. The median number of indicator bacteria in stormwater ranged from 0.1 to 10 billion MPN/100 ml. Fecal coliforms and fecal streptococci increased by 1 to 2 orders of magnitude during the warm season. The use of recharge basins to dispose of storm runoff does not appear to have significant adverse effects on groundwater quality in terms of the chemical and microbiological stormwater constituents studied. (Author 's abstract)
Measurement of radon progenies using the Timepix detector.
Bulanek, Boris; Jilek, Karel; Cermak, Pavel
2014-07-01
After an introduction of Timepix detector, results of these detectors with silicon and cadmium telluride detection layer in assessment of activity of short-lived radon decay products are presented. They were collected on an open-face filter by means of one-grab sampling method from the NRPI radon chamber. Activity of short-lived radon decay products was estimated from measured alpha decays of 218,214Po. The results indicate very good agreement between the use of both Timepix detectors and an NRPI reference instrument, continuous monitor Fritra 4. Low-level detection limit for EEC was estimated to be 41 Bq m(-3) for silicon detection layer and 184 Bq m(-3) for CdTe detection layer, respectively. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Field Performance of ISFET based Deep Ocean pH Sensors
NASA Astrophysics Data System (ADS)
Branham, C. W.; Murphy, D. J.
2017-12-01
Historically, ocean pH time series data was acquired from infrequent shipboard grab samples and measured using labor intensive spectrophotometry methods. However, with the introduction of robust and stable ISFET pH sensors for use in ocean applications a paradigm shift in the methods used to acquire long-term pH time series data has occurred. Sea-Bird Scientific played a critical role in the adoption this new technology by commercializing the SeaFET pH sensor and float pH Sensor developed by the MBARI chemical sensor group. Sea-Bird Scientific continues to advance this technology through a concerted effort to improve pH sensor accuracy and reliability by characterizing their performance in the laboratory and field. This presentation will focus on calibration of the ISFET pH sensor, evaluate its analytical performance, and validate performance using recent field data.
Alvarez, D.A.; Petty, J.D.; Huckins, J.N.; Jones-Lepp, T. L.; Getting, D.T.; Goddard, J.P.; Manahan, S.E.
2004-01-01
Increasingly it is being realized that a holistic hazard assessment of complex environmental contaminant mixtures requires data on the concentrations of hydrophilic organic contaminants including new generation pesticides, pharmaceuticals, personal care products, and many chemicals associated with household, industrial, and agricultural wastes. To address this issue, we developed a passive in situ sampling device (the polar organic chemical integrative sampler [POCIS]) that integratively concentrates trace levels of complex mixtures of hydrophilic environmental contaminants, enables the determination of their time-weighted average water concentrations, and provides a method of estimating the potential exposure of aquatic organisms to the complex mixture of waterborne contaminants. Using a prototype sampler, linear uptake of selected herbicides and pharmaceuticals with log KowS < 4.0 was observed for up to 56 d. Estimation of the ambient water concentrations of chemicals of interest is achieved by using appropriate uptake models and determination of POCIS sampling rates for appropriate exposure conditions. Use of POCIS in field validation studies targeting the herbicide diuron in the United Kingdom resulted in the detection of the chemical at estimated concentrations of 190 to 600 ng/L. These values are in agreement with reported levels found in traditional grab samples taken concurrently.
Mass balance of decabromodiphenyl ethane and decabromodiphenyl ether in a WWTP.
Ricklund, Niklas; Kierkegaard, Amelie; McLachlan, Michael S; Wahlberg, Cajsa
2009-01-01
The additive flame retardant decabromodiphenyl ethane (deBDethane) has been identified in the environment, but little is known about its environmental behaviour. It is structurally similar to decabromodiphenyl ether (decaBDE), making it conceivable that it may also become an environmental contaminant of concern. In this study a mass balance of deBDethane and decaBDE was undertaken in a modern WWTP in Stockholm serving 7.05x10(5) inhabitants. Flow proportional samples of plant influent and effluent as well as daily grab samples of digested sludge were collected during two 7-day periods. All samples were analyzed with GC/HRMS using isotope labelled internal standards. The mean mass flows of deBDethane and decaBDE to the WWTP were 6.0 g per day and 55 g per day, respectively. Of this, less than 1% of both BFRs left the WWTP via the effluent, while the bulk was sequestered into the digested sludge, where the mean concentrations of deBDethane and decaBDE were 81 and 800 ng g(-1)d.wt., respectively. It is concluded that the transfer efficiency of deBDethane from the technosphere to the environment via WWTPs is similar to that of decaBDE.
Evaluation of the Air Quality Monitor's Performance on the International Space Station
NASA Technical Reports Server (NTRS)
Limero, Thomas; Reese, Eric; Ballard, Ken; Durham, Tamara
2010-01-01
The Air Quality Monitor (AQM) was flown to the International Space Station (ISS) as an experiment to evaluate its potential to replace the aging Volatile Organic Analyzer (VOA), which ceased operations in August 2009. The AQM (Figure 1) is a small gas chromatography/differential mobility spectrometer (GC/DMS) manufactured by Sionex. Data was presented at last year s ISIMS conference that detailed the preparation of the AQM for flight, including instrument calibration. Furthermore, initial AQM data was compared to VOA results from simultaneous runs of the two instruments. Although comparison with VOA data provided a measure of confidence in the AQM performance, it is the comparison with results from simultaneously acquired air samples (grab sample containers-GSCs) that will define the success (or failure) of the AQM performance. This paper will update the progress in the AQM investigation by comparing AQM data to results from the analyses of GSC samples, returned from ISS. Additionally, a couple of example will illustrate the AQM s ability to detect disruptions in the spacecraft s air quality. Discussion will also focus upon a few unexpected issues that have arisen and how these will be a addressed in the final operational unit now being built.
Use of low density polyethylene membranes for assessment of genotoxicity of PAHs in the Seine River.
Vincent-Hubert, Françoise; Uher, Emmanuelle; Di Giorgio, Carole; Michel, Cécile; De Meo, Michel; Gourlay-France, Catherine
2017-03-01
The genotoxicity of river water dissolved contaminants is usually estimated after grab sampling of river water. Water contamination can now be obtained with passive samplers that allow a time-integrated sampling of contaminants. Since it was verified that low density polyethylene membranes (LDPE) accumulate labile hydrophobic compounds, their use was proposed as a passive sampler. This study was designed to test the applicability of passive sampling for combined chemical and genotoxicity measurements. The LDPE extracts were tested with the umu test (TA1535/pSK1002 ± S9) and the Ames assay (TA98, TA100 and YG1041 ± S9). We describe here this new protocol and its application in two field studies on four sites of the Seine River. Field LDPE extracts were negative with the YG1041 and TA100 and weakly positive with the TA98 + S9 and Umu test. Concentrations of labile mutagenic PAHs were higher upstream of Paris than downstream of Paris. Improvement of the method is needed to determine the genotoxicity of low concentrations of labile dissolved organic contaminants.
A Summary of Research and Progress on Carbon Monoxide Exposure Control Solutions on Houseboats
Hall, Ronald M.; Earnest, G. Scott; Hammond, Duane R.; Dunn, Kevin H.; Garcia, Alberto
2015-01-01
Investigations of carbon monoxide (CO-related poisonings and deaths on houseboats were conducted by the Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health. These investigations measured hazardous CO concentrations on and around houseboats that utilize gasoline-powered generators. Engineering control devices were developed and tested to mitigate this deadly hazard. CO emissions were measured using various sampling techniques which included exhaust emission analyzers, detector tubes, evacuated containers (grab air samples analyzed by a gas chromatograph), and direct-reading CO monitors. CO results on houseboats equipped with gasoline-powered generators without emission controls indicated hazardous CO concentrations exceeding immediately dangerous to life and health (IDLH) levels in potentially occupied areas of the houseboat. Air sample results on houseboats that were equipped with engineering controls to remove the hazard were highly effective and reduced CO levels by over 98% in potentially occupied areas. The engineering control devices used to reduce the hazardous CO emissions from gasoline-powered generators on houseboats were extremely effective at reducing CO concentrations to safe levels in potentially occupied areas on the houseboats and are now beginning to be widely used. PMID:24568306
Bemvenuti, C E; Angonesi, L G; Gandra, M S
2005-11-01
An evaluation was made of the effects of dredging on the soft bottom community in the channel of the Rio Grande harbor in the Patos Lagoon estuarine region of southern Brazil. During four seasonal cruises, samples were collected from nine biological stations, one of which was located outside the dredged area. Three macrobenthic samples were collected on each cruise from each station, using a 0.08 m2 van Veen grab. A cluster analysis was applied to group summer and autumn cruise stations before the dredging period, revealing larger numbers of species (35-36 spp.) and higher densities of organisms. The station located outside the dredging area was always included in this group, regardless of the sampling period or conditions of salinity. Another group comprised the winter and spring stations during the dredging period. This group was characterized by stations with the fewest species (20-18 spp.) and the lowest and most variable organism densities. The efficient strategies of resilience of the dominant estuarine species may minimize the effects of dredging on the biota through the rapid recolonization of the soft bottom of the harbor channel.
Rochelle-Newall, Emma J; Ribolzi, Olivier; Viguier, Marion; Thammahacksa, Chanthamousone; Silvera, Norbert; Latsachack, Keooudone; Dinh, Rinh Pham; Naporn, Piyapong; Sy, Hai Tran; Soulileuth, Bounsamay; Hmaimum, Nikom; Sisouvanh, Pem; Robain, Henri; Janeau, Jean-Louis; Valentin, Christian; Boithias, Laurie; Pierret, Alain
2016-09-08
Lack of access to clean water and adequate sanitation continues to be a major brake on development. Here we present the results of a 12-month investigation into the dynamics of Escherichia coli, a commonly used indicator of faecal contamination in water supplies, in three small, rural catchments in Laos, Thailand and Vietnam. We show that land use and hydrology are major controlling factors of E. coli concentrations in streamwater and that the relative importance of these two factors varies between the dry and wet seasons. In all three catchments, the highest concentrations were observed during the wet season when storm events and overland flow were highest. However, smaller peaks of E. coli concentration were also observed during the dry season. These latter correspond to periods of intense farming activities and small, episodic rain events. Furthermore, vegetation type, through land use and soil surface crusting, combined with mammalian presence play an important role in determining E. coli loads in the streams. Finally, sampling during stormflow revealed the importance of having appropriate sampling protocols if information on maximum contamination levels is required as grab sampling at a fixed time step may miss important peaks in E. coli numbers.
A summary of research and progress on carbon monoxide exposure control solutions on houseboats.
Hall, Ronald M; Earnest, G Scott; Hammond, Duane R; Dunn, Kevin H; Garcia, Alberto
2014-01-01
Investigations of carbon monoxide (CO-related poisonings and deaths on houseboats were conducted by the Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health. These investigations measured hazardous CO concentrations on and around houseboats that utilize gasoline-powered generators. Engineering control devices were developed and tested to mitigate this deadly hazard. CO emissions were measured using various sampling techniques which included exhaust emission analyzers, detector tubes, evacuated containers (grab air samples analyzed by a gas chromatograph), and direct-reading CO monitors. CO results on houseboats equipped with gasoline-powered generators without emission controls indicated hazardous CO concentrations exceeding immediately dangerous to life and health (IDLH) levels in potentially occupied areas of the houseboat. Air sample results on houseboats that were equipped with engineering controls to remove the hazard were highly effective and reduced CO levels by over 98% in potentially occupied areas. The engineering control devices used to reduce the hazardous CO emissions from gasoline-powered generators on houseboats were extremely effective at reducing CO concentrations to safe levels in potentially occupied areas on the houseboats and are now beginning to be widely used.
NASA Astrophysics Data System (ADS)
Rochelle-Newall, Emma J.; Ribolzi, Olivier; Viguier, Marion; Thammahacksa, Chanthamousone; Silvera, Norbert; Latsachack, Keooudone; Dinh, Rinh Pham; Naporn, Piyapong; Sy, Hai Tran; Soulileuth, Bounsamay; Hmaimum, Nikom; Sisouvanh, Pem; Robain, Henri; Janeau, Jean-Louis; Valentin, Christian; Boithias, Laurie; Pierret, Alain
2016-09-01
Lack of access to clean water and adequate sanitation continues to be a major brake on development. Here we present the results of a 12-month investigation into the dynamics of Escherichia coli, a commonly used indicator of faecal contamination in water supplies, in three small, rural catchments in Laos, Thailand and Vietnam. We show that land use and hydrology are major controlling factors of E. coli concentrations in streamwater and that the relative importance of these two factors varies between the dry and wet seasons. In all three catchments, the highest concentrations were observed during the wet season when storm events and overland flow were highest. However, smaller peaks of E. coli concentration were also observed during the dry season. These latter correspond to periods of intense farming activities and small, episodic rain events. Furthermore, vegetation type, through land use and soil surface crusting, combined with mammalian presence play an important role in determining E. coli loads in the streams. Finally, sampling during stormflow revealed the importance of having appropriate sampling protocols if information on maximum contamination levels is required as grab sampling at a fixed time step may miss important peaks in E. coli numbers.
Toxicological Assessment of ISS Air Quality: April - May 2013. [Increment 35
NASA Technical Reports Server (NTRS)
Meyers, Valerie
2013-01-01
A summary of the analytical results from 4 mini-grab sample (mGSCs) collected on ISS and returned aboard 33S is shown in Table 1. Due to the launch delay of the ATV4 resupply mission, monthly samples were reduced in April and May by omitting sampling of the Service Module in order to ensure contingency samplers were available if needed. Complete data tables of all measured concentrations and corresponding T-values based on 180-day SMACs are enclosed. detection limit for all target compounds, except m/p-xylenes and hexachloro-1, 3-butadiene was 0.025 mg/cu m. The detection limit for m/p-xylenes and hexachloro-1, 3-butadiene and all non-target compounds was 0.05 mg/cu m. The average recoveries of the 3 surrogate standards from the mGSCs were as follows: C-13-acetone, 116 +/- 12%; D-5-fluorobenzene, 117 +/- 7%; and D-5-chlorobenzene, 111 +/- 15%. Initial measured sample pressures were between 13.9 and 14.1 psia for all samples, indicating nominal sample collection. A summary of the analytical results from 3 pairs of passive-diffusion formaldehyde badges collected on ISS and returned aboard 33S is also provided in Table 1. In an effort to conserve samples due to the delay of the ATV4 resupply mission, FMK sampling was only conducted in the US Lab in May. Positive control recoveries (1 trip and 2 lab controls) were 79%, 87%, and 116% respectively.
Snyder, Richard A; Ederington-Hagy, Melissa; Hileman, Fredrick; Moss, Joseph A; Amick, Lauren; Carruth, Rebecca; Head, Marie; Marks, Joel; Tominack, Sarah; Jeffrey, Wade H
2014-12-15
The Florida Panhandle continental shelf environment was exposed to oil from the BP oil well failure in the Gulf of Mexico during 2010. Floating mats of oil were documented by satellite, but the distribution of dissolved components of the oil in this region was unknown. Shipek® grab samples of sediments were taken during repeated cruises between June 2010 and June 2012 to test for selected polycyclic aromatic hydrocarbons (PAHs) as indicators of this contamination. Sediments were collected as composite samples, extracted using standard techniques, and PAHs were quantified by GC/MS-SIM. PAHs in samples from the continental slope in May 2011 were highest near to the failed well site and were reduced in samples taken one year later. PAHs from continental shelf sediments during the spill (June 2010) ranged from 10 to 165 ng g(-1). Subsequent cruises yielded variable and reduced amounts of PAHs across the shelf. The data suggest that PAHs were distributed widely across the shelf, and their subsequent loss to background levels suggests these compounds were of oil spill origin. PAH half-life estimates by regression were 70-122 days for slope and 201 days for shelf stations. Copyright © 2014 Elsevier Ltd. All rights reserved.
INTEGRATIVE SAMPLING OF ANTIBIOTICS AND OTHER ...
Pharmaceuticals from human and veterinary use continually enter the environment through municipal wastewater treatment plants (WWTPs), surface runoff from animal waste, and direct disposal of unused medications. The presence of these chemicals, albeit often at subtherapeutic trace levels, may be partly responsible for development of antibiotic-resistant bacteria and sublethal effects in aquatic organisms. Conventional sampling techniques (i.e., grab sampling) often are insufficient for detecting these trace levels. A new sampling technique, the Polar Organic Chemical Integrative Sampler (POCIS), developed by scientists at the USGS's Columbia Environmental Research Center, can provide the time-weighted average concentrations of these complex mixtures. A pilot study targeting the antibiotic azithromycin involved deploying the POCIS for 30 days in the effluents of three WWTPs in Nevada, Utah, and South Carolina. Azithromycin was detected at each WWTP at 19 to 66 ng/L. This translates to a yearly loading, into each of the three receiving waters, of 0.4 to 4 kg/year. In a separate study investigating potential impacts of confined animal feeding operations on national wildlife refuges in the Delmarva peninsula, the antibiotic tetracycline and the natural hormone 17B-estradiol were detected at multiple sites. The research focused on in the subtasks is the development and application of state-of the-art technologies to meet the needs of the public, Office of Water, and
WATER QUALITY MONITORING OF PHARMACEUTICALS ...
The demand on freshwater to sustain the needs of the growing population is of worldwide concern. Often this water is used, treated, and released for reuse by other communities. The anthropogenic contaminants present in this water may include complex mixtures of pesticides, prescription and nonprescription drugs, personal care and common consumer products, industrial and domestic-use materials and degradation products of these compounds. Although, the fate of these pharmaceuticals and personal care products (PPCPs) in wastewater treatment facilities is largely unknown, the limited data that does exist suggests that many of these chemicals survive treatment and some others are returned to their biologically active form via deconjugation of metabolites.Traditional water sampling methods (i.e., grab or composite samples) often require the concentration of large amounts of water to detect trace levels of PPCPs. A passive sampler, the polar organic chemical integrative sampler (POCIS), has been developed to integratively concentrate the trace levels of these chemicals, determine the time-weighted average water concentrations, and provide a method of estimating the potential exposure of aquatic organisms to these complex mixtures of waterborne contaminants. The POCIS (U.S. Patent number 6,478,961) consists of a hydrophilic microporous membrane, acting as a semipermeable barrier, enveloping various solid-phase sorbents that retain the sampled chemicals. Sampling rates f
NASA Astrophysics Data System (ADS)
Engelbrecht, Johann P.; Moosmüller, Hans; Pincock, Samuel; Jayanty, R. K. M.; Lersch, Traci; Casuccio, Gary
2016-08-01
This paper promotes an understanding of the mineralogical, chemical, and physical interrelationships of re-suspended mineral dusts collected as grab samples from global dust sources. Surface soils were collected from arid regions, including the southwestern USA, Mali, Chad, Morocco, Canary Islands, Cabo Verde, Djibouti, Afghanistan, Iraq, Kuwait, Qatar, UAE, Serbia, China, Namibia, Botswana, Australia, and Chile. The < 38 µm sieved fraction of each sample was re-suspended in a chamber, from which the airborne mineral dust could be extracted, sampled, and analyzed. Instruments integrated into the entrainment facility included two PM10 and two PM2.5 filter samplers, a beta attenuation gauge for the continuous measurement of PM10 and PM2.5 particulate mass fractions, an aerodynamic particle size analyzer, and a three-wavelength (405, 532, 781 nm) photoacoustic instrument with integrating reciprocal nephelometer for monitoring absorption and scattering coefficients during the dust re-suspension process. Filter sampling media included Teflon® membrane and quartz fiber filters for chemical analysis and Nuclepore® filters for individual particle analysis by scanning electron microscopy (SEM). The < 38 µm sieved fractions were also analyzed by X-ray diffraction for their mineral content while the > 75, < 125 µm soil fractions were mineralogically assessed by optical microscopy. Presented here are results of the optical measurements, showing the interdependency of single-scattering albedos (SSA) at three different wavelengths and mineralogical content of the entrained dust samples. To explain the elevated concentrations of iron (Fe) and Fe / Al ratios in the soil re-suspensions, we propose that dust particles are to a large extent composed of nano-sized particles of micas, clays, metal oxides, and ions of potassium (K+), calcium (Ca2+), and sodium (Na+) evenly dispersed as a colloid or adsorbed in amorphous clay-like material. Also shown are differences in SSA of the kaolinite/hematite/goethite samples from Mali and those from colloidal soils elsewhere. Results from this study can be integrated into a database of mineral dust properties, for applications in climate modeling, remote sensing, visibility, health (medical geology), ocean fertilization, and impact on equipment.
2009-09-10
and a third for municipal elections. 7 “Constitutional reform or power grab,” Latin American Weekly Report, March 26, 2009. 8 Both candidates have...the resignations of Honduran Defense Minister Edmundo Orellana Mercado and Chairman of the Joint Chiefs of Staff Romeo Vasquez Velasquez after they
76 FR 60405 - Inflatable Personal Flotation Devices
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-29
... criteria for the grab breaking strength, tear strength, seam strength, and permeability tests for inflation... Determining Gas Permeability Characteristics of Plastic Film and Sheeting), because those standards, or... Government and Indian tribes, or on the distribution of power and responsibilities between the Federal...
76 FR 17561 - Inflatable Personal Flotation Devices
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-30
... the grab breaking strength, tear strength, seam strength, and permeability tests for inflation chamber... Coated Fabrics), and ASTM D 1434-82 (Standard Test Method for Determining Gas Permeability... Government and Indian tribes, or on the distribution of power and responsibilities between the Federal...
How well do we know the infaunal biomass of the continental shelf?
NASA Astrophysics Data System (ADS)
Powell, Eric N.; Mann, Roger
2016-03-01
Benthic infauna comprise a wide range of taxa of varying abundances and sizes, but large infaunal taxa are infrequently recorded in community surveys of the shelf benthos. These larger, but numerically rare, species may contribute disproportionately to biomass, however. We examine the degree to which standard benthic sampling gear and survey design provide an adequate estimate of the biomass of large infauna using the Atlantic surfclam, Spisula solidissima, on the continental shelf off the northeastern coast of the United States as a test organism. We develop a numerical model that simulates standard survey designs, gear types, and sampling densities to evaluate the effectiveness of vertically-dropped sampling gear (e.g., boxcores, grabs) for estimating density of large species. Simulations of randomly distributed clams at a density of 0.5-1 m-2 within an 0.25-km2 domain show that lower sampling densities (1-5 samples per sampling event) resulted in highly inaccurate estimates of clam density with the presence of clams detected in less than 25% of the sampling events. In all cases in which patchiness was present in the simulated clam population, surveys were prone to very large errors (survey availability events) unless a dense (e.g., 100-sample) sampling protocol was imposed. Thus, commercial quantities of surfclams could easily go completely undetected by any standard benthic community survey protocol using vertically-dropped gear. Without recourse to modern high-volume sampling gear capable of sampling many meters at a swath, such as hydraulic dredges, biomass of the continental shelf will be grievously underestimated if large infauna are present even at moderate densities.
Haller, T; Van Dijk, H; Bollig, M; Greiner, C; Schareika, N; Gabbert, C
2016-11-01
This paper argues that pastoral commons are under increasing pressure not just from overuse by pastoralists themselves, but from land management policies. Since colonial times, these have been based on a persistent misconception of the nature of pastoral economies and combined with increasing land alienation and fragmentation through government policies and covert privatisation of pastures. The paper focuses especially on pastoral populations in African drylands and is based on long-term research by independent researchers summarising some of their experiences in western, eastern and southern Africa. Most of them are organised in the African Drylands Dialogue, trying to shed some light on the developments in these areas. Before discussing the actual situation of African pastoralists, the authors focus on basic institutional features of the political and economic management of common grazing lands. This is followed by an overview of land alienation processes in colonial times, which serves as a basis for understanding the current land alienation constellations. The paper then moves on to explain how and why pastoralists are framed by the national discourses as the 'other' and the 'troublemaker', even being labelled as terrorists in nation state contexts. This goes hand in hand with a new wave of land alienation in the form of large-scale land acquisitions or 'land grabbing' (including water grabbing and 'green grabbing' processes). The paper then outlines different coping and adaptation strategies adopted by pastoral groups in a context in which a range of different global and local political, economic and ecological situations interrelate ('glocal'). Finally, the paper discusses the way in which pastoralism could be reframed in a participatory way in the future.
Analysis of angular momentum effect on swimming kick-start performance.
Taladriz, Sonia; de la Fuente-Caynzos, Blanca; Arellano, Raúl
2016-06-14
The aim of this study was to analyse the mechanics of rotation and the temporal, angular and kinematics variables during the aerial phase for the kick-start with respect to the grab start. Nine elite swimmers (70.0 ± 7.7 kg; 178 ± 9.4 cm; 24.5 ± 5.3 years; 824 ± 119 FINA points scoring) performed the starts on the OMEGA OSB11 starting block followed by 5 m gliding at maximum velocity. Nineteen comparisons of kinematics variables across start technique were performed with critical alpha adjusted using a Holm's correction to maintain an experiment-wise type I error rate of p <0.05. The differences were statistically evaluated by T-test and Wilcoxon test. Significant advantages for the kick-start were observed in all temporal variables (except in the flight time) and in the vertical take-off velocity. Similarities in the centre of mass angular momentum at take-off (120.89 ± 17.66, 126.61 ± 13.51 s(-1).10(-3), p-value <0.294; kick-start and grab start) caused that KS did not increase the temporal advantages obtained on the block at 5 m distance. Two different rotational movements were found for both techniques. A displacement of the rear leg and front leg on the block and during the flight respectively permits a higher lower limbs position relative to the trunk at hands entry for kick-start. However, larger rotational movement of the trunk characterized grab start. It was concluded that shorter block times and rotational displacements of the lower limbs on the block and flight phase are the key of the best performance for kick-start at 5 m distance. Copyright © 2016 Elsevier Ltd. All rights reserved.
Puget Sound sediment-trap data: 1980-1985. Data report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paulson, A.J.; Baker, E.T.; Feely, R.A.
1991-12-01
In 1979, scientists at the Pacific Marine Environmental Laboratory began investigating the sources, transformation, transport and fate of pollutants in Puget Sound and its watershed under Sec. 202 of the Marine Protection, Research and Sanctuaries Act of 1971 (P.L. 92-532) which called in part for '...a comprehensive and continuing program of research with respect to the possible long range effects of pollution, overfishing, and man-induced changes of ocean ecosystems...' The effort was called the Long-Range Effects Research Program (L-RERP) after language in the Act and was later called the PMEL Marine Environmental Quality Program. The Long-Range Effect Research Program consistedmore » of (1) sampling dissolved and particulate constituents in the water column by bottle sampling, (2) sampling settling particles by sediment trap and (3) sampling sediments by grab, box, gravity and Kasten corers. In the Data Report, a variety of data from particles collected in 104 traps deployed on 34 moorings in open waters between 1980 and 1985 are presented. The text of the data report begins with the sampling and analytical methods with the accompanying quality control/quality assurance data. The text of the data sections are a summary of the available data and published literature in which the data is interpreted along with a catalogue of the data available in the Appendix (on microfiche located in the back pocket of the data report).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riscassi, Ami L; Miller, Carrie L; Brooks, Scott C
Mercury (Hg) and methylmercury (MeHg) concentrations in streamwater can vary on short timescales (hourly or less) during storm flow and on a diel cycle; the frequency and timing of sampling required to accurately characterize these dynamics may be difficult to accomplish manually. Automated sampling can assist in sample collection; however use has been limited for Hg and MeHg analysis due to stability concerns of trace concentrations during extended storage times. We examined the viability of using automated samplers with disposable low-density polyethylene (LDPE) sample bags to collect industrially contaminated streamwater for unfiltered and filtered Hg and MeHg analysis. Specifically wemore » investigated the effect of holding times ranging from hours to days on streamwater collected during baseflow and storm flow. Unfiltered and filtered Hg and MeHg concentrations decreased with increases in time prior to sample processing; holding times of 24 hours or less resulted in concentration changes (mean 11 7% different) similar to variability in duplicates collected manually during analogous field conditions (mean 7 10% different). Comparisons of samples collected with manual and automated techniques throughout a year for a wide range of stream conditions were also found to be similar to differences observed between duplicate grab samples. These results demonstrate automated sampling into LDPE bags with holding times of 24 hours or less can be effectively used to collect streamwater for Hg and MeHg analysis, and encourage the testing of these materials and methods for implementation in other aqueous systems where high-frequency sampling is warranted.« less
Nonlinear effects of group size on the success of wolves hunting elk
MacNulty, Daniel R.; Smith, Douglas W.; Mech, L. David; Vucetich, John A.; Packer, Craig
2012-01-01
Despite the popular view that social predators live in groups because group hunting facilitates prey capture, the apparent tendency for hunting success to peak at small group sizes suggests that the formation of large groups is unrelated to prey capture. Few empirical studies, however, have tested for nonlinear relationships between hunting success and group size, and none have demonstrated why success trails off after peaking. Here, we use a unique dataset of observations of individually known wolves (Canis lupus) hunting elk (Cervus elaphus) in Yellowstone National Park to show that the relationship between success and group size is indeed nonlinear and that individuals withholding effort (free riding) is why success does not increase across large group sizes. Beyond 4 wolves, hunting success leveled off, and individual performance (a measure of effort) decreased for reasons unrelated to interference from inept hunters, individual age, or size. But performance did drop faster among wolves with an incentive to hold back, i.e., nonbreeders with no dependent offspring, those performing dangerous predatory tasks, i.e., grabbing and restraining prey, and those in groups of proficient hunters. These results suggest that decreasing performance was free riding and that was why success leveled off in groups with >4 wolves that had superficially appeared to be cooperating. This is the first direct evidence that nonlinear trends in group hunting success reflect a switch from cooperation to free riding. It also highlights how hunting success per se is unlikely to promote formation and maintenance of large groups.
Grilling with a Healthier Mindset | Poster
Summer means another chance to grab some ribs and fire up the grill, but eating certain types of grilled meat may increase your chances of developing cancer. Here is a glimpse of how cancer and grilling are related and some ways you can lower your risk.
46 CFR 160.176-4 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
... and Elongation, Breaking of Woven Cloth; Grab Method, incorporation by reference approved for § 160.176-13. (ii) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method, incorporation by reference approved for § 160.176-13. (iii) Method 5134, Strength of Cloth, Tearing; Tongue Method...
46 CFR 160.176-4 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
... and Elongation, Breaking of Woven Cloth; Grab Method, incorporation by reference approved for § 160.176-13. (ii) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method, incorporation by reference approved for § 160.176-13. (iii) Method 5134, Strength of Cloth, Tearing; Tongue Method...
46 CFR 160.077-5 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., Breaking of Woven Cloth; Grab Method. (ii) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method. (iii) Method 5134, Strength of Cloth, Tearing; Tongue Method. (iv) Method 5804.1, Weathering Resistance of Cloth; Accelerated Weathering Method. (v) Method 5762, Mildew Resistance of Textile Materials...
46 CFR 160.077-5 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Elongation, Breaking of Woven Cloth; Grab Method. (2) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method. (3) Method 5134, Strength of Cloth, Tearing; Tongue Method. (4) Method 5804.1, Weathering Resistance of Cloth; Accelerated Weathering Method. (5) Method 5762, Mildew Resistance of Textile Materials...
46 CFR 160.077-5 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., Breaking of Woven Cloth; Grab Method. (ii) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method. (iii) Method 5134, Strength of Cloth, Tearing; Tongue Method. (iv) Method 5804.1, Weathering Resistance of Cloth; Accelerated Weathering Method. (v) Method 5762, Mildew Resistance of Textile Materials...
46 CFR 160.077-5 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Elongation, Breaking of Woven Cloth; Grab Method. (2) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method. (3) Method 5134, Strength of Cloth, Tearing; Tongue Method. (4) Method 5804.1, Weathering Resistance of Cloth; Accelerated Weathering Method. (5) Method 5762, Mildew Resistance of Textile Materials...
ERIC Educational Resources Information Center
Ruda, Tammie L.
2011-01-01
A challenge gift helps fundraisers reach goals by stimulating multiple aspects of a fundraising program. First, the message of a challenge grabs the attention of prospects and generally generates excitement beyond the case for support. It also commands the attention of the prospect managers in an organization, particularly when the challenge…
ERIC Educational Resources Information Center
Hignite, Karla
2009-01-01
Green information technology (IT) is grabbing more mainstream headlines--and for good reason. Computing, data processing, and electronic file storage collectively account for a significant and growing share of energy consumption in the business world and on higher education campuses. With greater scrutiny of all activities that contribute to an…
Novel low-cost vision-sensing technology with controllable of exposal time for welding
NASA Astrophysics Data System (ADS)
Zhang, Wenzeng; Wang, Bin; Chen, Nian; Cao, Yipeng
2005-02-01
In the process of robot Welding, position of welding seam and welding pool shape is detected by CCD camera for quality control and seam tracking in real-time. It is difficult to always get a clear welding image in some welding methods, such as TIG welding. A novel idea that the exposal time of CCD camera is automatically controlled by arc voltage or arc luminance is proposed to get clear welding image. A set of special device and circuits are added to a common industrial CCD camera in order to flexibly control the CCD to start or close exposal by control of the internal clearing signal of the accumulated charge. Two special vision sensors according to the idea are developed. Their exposal grabbing can be triggered respectively by the arc voltage and the variety of the arc luminance. Two prototypes have been designed and manufactured. Experiments show that they can stably grab clear welding images at appointed moment, which is a basic for the feedback control of automatic welding.
2017-12-08
Asteroid Bennu is a time capsule, containing the raw ingredients of the solar system. Bennu has settled in a near-Earth orbit. Today, a NASA spacecraft OSIRIS-REx is going to retrieve a sample to learn more about our Solar System’s history. OSIRIRS-REx is a NASA sample return mission to visit Asteroid Bennu. We plan to grab a piece of Bennu, because it’s a time capsule that can tell us about the origins of our planet and our entire solar system. Watch the full video: youtu.be/gtUgarROs08 Learn more about NASA’s OSIRIS-REx mission and the making of Bennu’s Journey: www.nasa.gov/content/goddard/bennus-journey/ More information on the OSIRIS-REx mission is available at: www.nasa.gov/mission_pages/osiris-rex/index.html www.asteroidmission.org NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Observations of cocooned Hydrobaenus (Diptera: Chironomidae) larvae in Lake Michigan
Tucker, Taaja R.; Hudson, Patrick L.; Riley, Stephen
2016-01-01
Larvae of the family Chironomidae have developed a variety of ways to tolerate environmental stress, including the formation of cocoons, which allows larvae to avoid unfavorable temperature conditions, drought, or competition with other chironomids. Summer cocoon formation by younger instars of the genus Hydrobaenus Fries allows persistence through increased temperatures and/or intermittent dry periods in arid regions or temporary habitats, but this behavior was not observed in the Great Lakes until the current study. Cocoon-aestivating Hydrobaenus sp. larvae were found in benthic grab samples collected in 2010–2013 near Sleeping Bear Dunes National Lakeshore in northern Lake Michigan with densities up to 7329/m2. The aestivating species was identified as Hydrobaenus johannseni (Sublette, 1967), and the associated chironomid community was typical for an oligotrophic nearshore system. Hydrobaenus cocoon formation in the Great Lakes was likely previously unnoticed due to the discrepancies between the genus' life history and typical benthos sampling procedures which has consequences for describing chironomid communities where Hydrobaenus is present.
Al-Zahrany, A A; Farouk, M A; Al-Yousef, A A
2012-11-01
The present work is a part of a project dedicated to measure the marine radioactivity near the Saudi Arabian coasts of the Red Sea and Arabian Gulf for establishing a marine radioactivity database, which includes necessary information on the background levels of both naturally occurring and man-made radionuclides in the marine environment. Farasan Islands is a group of 84 islands (archipelago), under the administration of the Kingdom of Saudi Arabia, in the Red Sea with its main island of Farasan, which is 50 km off the coast of Jazan City. The levels of natural radioactivity of (238)U, (235)U, (226)Ra, (232)Th and (40)K and man-made radionuclides such as (137)Cs in the grab sediment and water samples around Farasan Island have been measured using gamma-ray spectroscopy. The average activity concentrations of (238)U, (235)U, (226)Ra, (232)Th, (40)K and (137)Cs in the sediment samples were found to be 35.46, 1.75, 3.31, 0.92, 34.34 and 0.14 Bq kg(-1), respectively.
2017-12-08
This large asteroid, a proto-star undergoes fusion and our sun is born. This is the parent of Asteroid Bennu. Today, a NASA Spacecraft has the chance to retrieve a sample from Bennu to reveal the history of our solar system. OSIRIRS-REx is a NASA sample return mission to visit Asteroid Bennu. We plan to grab a piece of Bennu, because it’s a time capsule that can tell us about the origins of our planet and our entire solar system. Watch the full video: youtu.be/gtUgarROs08 Learn more about NASA’s OSIRIS-REx mission and the making of Bennu’s Journey: www.nasa.gov/content/goddard/bennus-journey/ More information on the OSIRIS-REx mission is available at: www.nasa.gov/mission_pages/osiris-rex/index.html www.asteroidmission.org NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Fluorochemical Mass Flows in a Municipal Wastewater Treatment Facility
Schultz, Melissa M.; Higgins, Christopher P.; Huset, Carin A.; Luthy, Richard G.; Barofsky, Douglas F.; Field, Jennifer A.
2008-01-01
Fluorochemicals have widespread applications and are released into municipal wastewater treatment plants via domestic wastewater. A field study was conducted at a full-scale municipal wastewater treatment plant to determine the mass flows of selected fluorochemicals. Flow-proportional, 24-h samples of raw influent, primary effluent, trickling filter effluent, secondary effluent, and final effluent and grab samples of primary, thickened, activated, and anaerobically-digested sludge were collected over ten days and analyzed by liquid chromatography electrospray-ionization tandem mass spectrometry. Significant decreases in the mass flows of perfluorohexane sulfonate and perfluorodecanoate occurred during trickling filtration and primary clarification, while activated sludge treatment decreased the mass flow of perfluorohexanoate. Mass flows of the 6:2 fluorotelomer sulfonate and perfluorooctanoate were unchanged as a result of wastewater treatment, which indicates that conventional wastewater treatment is not effective for removal of these compounds. A net increase in the mass flows for perfluorooctane and perfluorodecane sulfonates occurred from trickling filtration and activated sludge treatment. Mass flows for perfluoroalkylsulfonamides and perfluorononanoate also increased during activated sludge treatment and are attributed to degradation of precursor molecules. PMID:17180988
ERIC Educational Resources Information Center
National Governors Association, 2007
2007-01-01
"Investing in Innovation" provides a snapshot of trends in the states and identifies a wide range of strategies now employed. California's big investments, such as $3 billion for stem cell research, have already grabbed national headlines. But states like Arizona, Indiana and North Dakota, which haven't historically been big research and…
46 CFR 160.076-11 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... following methods: (1) Method 5100, Strength and Elongation, Breaking of Woven Cloth; Grab Method, 160.076-25; (2) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method, 160.076-25; (3) Method 5134, Strength of Cloth, Tearing; Tongue Method, 160.076-25. Underwriters Laboratories (UL) Underwriters...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Storm rails. 169.329 Section 169.329 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Construction and Arrangement Rails and Guards § 169.329 Storm rails. Suitable storm rails or hand grabs must be...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Storm rails. 169.329 Section 169.329 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Construction and Arrangement Rails and Guards § 169.329 Storm rails. Suitable storm rails or hand grabs must be...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Storm rails. 169.329 Section 169.329 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Construction and Arrangement Rails and Guards § 169.329 Storm rails. Suitable storm rails or hand grabs must be...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Storm rails. 169.329 Section 169.329 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Construction and Arrangement Rails and Guards § 169.329 Storm rails. Suitable storm rails or hand grabs must be...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Storm rails. 169.329 Section 169.329 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Construction and Arrangement Rails and Guards § 169.329 Storm rails. Suitable storm rails or hand grabs must be...
ERIC Educational Resources Information Center
Hyde, Henry
1998-01-01
Constant attention by all Americans is needed to preserve what little local control in education remains. Chief among dangerous federal legislation moving the country toward a federal education system is the Goals 2000: Educate America Act. The paper examines Goals 2000 and other federal legislation that seeks to remove parental control, noting…
Meucci, Marissa R; Gozalo, Pedro; Dosa, David; Allen, Susan M
2016-10-01
To investigate the association between sociodemographic and economic factors and the presence of simple home modifications (HMs) among older adults in the United States. Cross-sectional. National Health and Aging Trends Study (2011, Round 1). Community-dwelling Medicare enrollees aged 65 and older (N = 6,628). The primary dependent variable was the reported presence or absence of simple HMs (grab bars in the shower or near the toilet, shower seats, raised toilet seats). Of the individuals sampled, 60.7% reported having at least one HM of interest. Black (odds ratio (OR) = 0.79, 95% confidence interval (CI) = 0.68-0.91) and Hispanic (OR = 0.60, 95% CI = 0.45-0.78) respondents were less likely than white, non-Hispanic respondents to have HMs. Those with more education (high school graduate: OR = 1.20, 95% CI = 1.01-1.42; >high school: OR = 1.36, 95% CI = 1.14-1.62) and larger social networks (≥4 people; OR = 1.46, 95% CI = 1.12-1.89) were more likely to have at least one HM, whereas being divorced (OR = 0.57, 95% CI = 0.43-0.74) was associated with lower likelihood. Income (OR = 1.01, 95% CI = 0.97-1.05), Medicaid enrollment (OR = 0.98, 95% CI = 0.77-1.25), and living alone (OR = 1.02, 95% CI = 0.85-1.23) were not significantly associated with the presence of HMs. Minorities, individuals with less education, and those with less social support are less likely to have HMs. Awareness of these disparities and the shortcomings of the HM delivery system is important to clinicians and policy-makers who seek to prevent falls and facilitate aging in place for all older Americans. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.
Zaremba, Nicholas J.; Smith, Kathryn E.L.; Bishop, James M.; Smith, Christopher G.
2016-08-04
Scientists from the United States Geological Survey, St. Petersburg Coastal and Marine Science Center, U.S. Geological Survey Pacific Coastal and Marine Science Center, and students from the University of Hawaii at Manoa collected sediment cores, sediment surface grab samples, ground-penetrating radar (GPR) and Differential Global Positioning System (DGPS) data from within the Edwin B. Forsythe National Wildlife Refuge–Holgate Unit located on the southern end of Long Beach Island, New Jersey, in April 2015 (FAN 2015-611-FA). The study’s objective was to identify washover deposits in the stratigraphic record to aid in understanding barrier island evolution. This report is an archive of GPR and DGPS data collected from Long Beach Island in 2015. Data products, including raw GPR and processed DGPS data, elevation corrected GPR profiles, and accompanying Federal Geographic Data Committee metadata can be downloaded from the Data Downloads page.
ANITA Air Monitoring on the International Space Station: Results Compared to Other Measurements
NASA Technical Reports Server (NTRS)
Honne, A.; Schumann-Olsen, H.; Kaspersen, K.; Limero, T.; Macatangay, A.; Mosebach, H.; Kampf, D.; Mudgett, P. D.; James, J. T.; Tan, G.;
2009-01-01
ANITA (Analysing Interferometer for Ambient Air) is a flight experiment precursor for a permanent continuous air quality monitoring system on the ISS (International Space Station). For the safety of the crew, ANITA can detect and quantify quasi-online and simultaneously 33 gas compounds in the air with ppm or sub-ppm detection limits. The autonomous measurement system is based on FTIR (Fourier Transform Infra-Red spectroscopy). The system represents a versatile air quality monitor, allowing for the first time the detection and monitoring of trace gas dynamics in a spacecraft atmosphere. ANITA operated on the ISS from September 2007 to August 2008. This paper summarizes the results of ANITA s air analyses with emphasis on comparisons to other measurements. The main basis of comparison is NASA s set of grab samples taken onboard the ISS and analysed on ground applying various GC-based (Gas Chromatography) systems.
Van Gorp, Baldwin; Vercruysse, Tom; Van den Bulck, Jan
2012-09-01
Starting point of this study was the assumption that Alzheimer's disease is made worse for the person who has the disease by the negative regard in which the illness is held by society. The aim was to test by means of a campaign advertisement whether more nuanced counterframes could have an impact while remaining credible and comprehensible to the public. A sample of thousand people living in Belgium evaluated the campaign in an experimental design. This revealed that all the versions tested achieved a high average evaluation. The ad in which the heading referred to the fear of death and degeneration was judged to be most attention-grabbing, easier to understand, and more credible than the alternative heading with the idea that someone with Alzheimer's could still enjoy playing cards. Together, these findings provided a basis for the use of counterframes to generating a more nuanced image of Alzheimer's disease.
Risley, John C.; Granato, Gregory E.
2014-01-01
6. An analysis of the use of grab sampling and nonstochastic upstream modeling methods was done to evaluate the potential effects on modeling outcomes. Additional analyses using surrogate water-quality datasets for the upstream basin and highway catchment were provided for six Oregon study sites to illustrate the risk-based information that SELDM will produce. These analyses show that the potential effects of highway runoff on receiving-water quality downstream of the outfall depends on the ratio of drainage areas (dilution), the quality of the receiving water upstream of the highway, and the concentration of the criteria of the constituent of interest. These analyses also show that the probability of exceeding a water-quality criterion may depend on the input statistics used, thus careful selection of representative values is important.
Frequency-duration analysis of dissolved-oxygen concentrations in two southwestern Wisconsin streams
Greb, Steven R.; Graczyk, David J.
2007-01-01
Historically, dissolved-oxygen (DO) data have been collected in the same manner as other water-quality constituents, typically at infrequent intervals as a grab sample or an instantaneous meter reading. Recent years have seen an increase in continuous water-quality monitoring with electronic dataloggers. This new technique requires new approaches in the statistical analysis of the continuous record. This paper presents an application of frequency-duration analysis to the continuous DO records of a cold and a warm water stream in rural southwestern Wisconsin. This method offers a quick, concise way to summarize large time-series data bases in an easily interpretable manner. Even though the two streams had similar mean DO concentrations, frequency-duration analyses showed distinct differences in their DO-concentration regime. This type of analysis also may be useful in relating DO concentrations to biological effects and in predicting low DO occurrences.
Water Security Toolkit User Manual: Version 1.3 | Science ...
User manual: Data Product/Software The Water Security Toolkit (WST) is a suite of tools that help provide the information necessary to make good decisions resulting in the minimization of further human exposure to contaminants, and the maximization of the effectiveness of intervention strategies. WST assists in the evaluation of multiple response actions in order to select the most beneficial consequence management strategy. It includes hydraulic and water quality modeling software and optimization methodologies to identify: (1) sensor locations to detect contamination, (2) locations in the network in which the contamination was introduced, (3) hydrants to remove contaminated water from the distribution system, (4) locations in the network to inject decontamination agents to inactivate, remove or destroy contaminants, (5) locations in the network to take grab sample to confirm contamination or cleanup and (6) valves to close in order to isolate contaminated areas of the network.
Evaluation of area strain response of dielectric elastomer actuator using image processing technique
NASA Astrophysics Data System (ADS)
Sahu, Raj K.; Sudarshan, Koyya; Patra, Karali; Bhaumik, Shovan
2014-03-01
Dielectric elastomer actuator (DEA) is a kind of soft actuators that can produce significantly large electric-field induced actuation strain and may be a basic unit of artificial muscles and robotic elements. Understanding strain development on a pre-stretched sample at different regimes of electrical field is essential for potential applications. In this paper, we report about ongoing work on determination of area strain using digital camera and image processing technique. The setup, developed in house consists of low cost digital camera, data acquisition and image processing algorithm. Samples have been prepared by biaxially stretched acrylic tape and supported between two cardboard frames. Carbon-grease has been pasted on the both sides of the sample, which will be compliant with electric field induced large deformation. Images have been grabbed before and after the application of high voltage. From incremental image area, strain has been calculated as a function of applied voltage on a pre-stretched dielectric elastomer (DE) sample. Area strain has been plotted with the applied voltage for different pre-stretched samples. Our study shows that the area strain exhibits nonlinear relationship with applied voltage. For same voltage higher area strain has been generated on a sample having higher pre-stretched value. Also our characterization matches well with previously published results which have been done with costly video extensometer. The study may be helpful for the designers to fabricate the biaxial pre-stretched planar actuator from similar kind of materials.
Sample Based Unit Liter Dose Estimates
DOE Office of Scientific and Technical Information (OSTI.GOV)
JENSEN, L.
The Tank Waste Characterization Program has taken many core samples, grab samples, and auger samples from the single-shell and double-shell tanks during the past 10 years. Consequently, the amount of sample data available has increased, both in terms of quantity of sample results and the number of tanks characterized. More and better data is available than when the current radiological and toxicological source terms used in the Basis for Interim Operation (BIO) (FDH 1999a) and the Final Safety Analysis Report (FSAR) (FDH 1999b) were developed. The Nuclear Safety and Licensing (NS and L) organization wants to use the new datamore » to upgrade the radiological and toxicological source terms used in the BIO and FSAR. The NS and L organization requested assistance in producing a statistically based process for developing the source terms. This report describes the statistical techniques used and the assumptions made to support the development of a new radiological source term for liquid and solid wastes stored in single-shell and double-shell tanks. The results given in this report are a revision to similar results given in an earlier version of the document (Jensen and Wilmarth 1999). The main difference between the results in this document and the earlier version is that the dose conversion factors (DCF) for converting {mu}Ci/g or {mu}Ci/L to Sv/L (sieverts per liter) have changed. There are now two DCFs, one based on ICRP-68 and one based on ICW-71 (Brevick 2000).« less
A Grab Bag of Nature Activities.
ERIC Educational Resources Information Center
Miller, Lenore
1993-01-01
Suggested nature activities include (1) sensory experiences to distinguish all characteristics of various objects; (2) adopt-a-tree activities where children learn about "their own" tree; (3) finding evidence of animals in nature; (4) nature questions of the week with prizes for correct answers; and (5) activities related to the…
1999-06-01
GRAB) satellite system 2. Multispectral IR image of a truck viewed in the afternoon using two MRIR bands and one LWIR band 3. In an effort to... nonuniformities of less than 0.25%. This photograph shows the largest amplifier in the laser. Light enters and exits the amplifier cell through the square aperture
ERIC Educational Resources Information Center
Occupational Outlook Quarterly, 2012
2012-01-01
This article presents brief items of interest to counselors and students. It introduces the National Student Exchange program that enables students in nearly 200 participating schools to attend classes on another campus in the United States for a semester or a year. It also describes the launching of social network jobs partnership by the U.S.…
2012-06-25
A frame grab from a mounted video camera on the E-3 Test Stand at Stennis Space Center documents testing of the new Project Morpheus engine. The new liquid methane, liquid oxygen engine will power the Morpheus prototype lander, which could one day evolve to carry cargo safely to the moon, asteroids or Mars surfaces.
Myth of the "Last-In" Superstar
ERIC Educational Resources Information Center
Chesley, Gary M.; Hartman, Diane M.
2011-01-01
In the new political landscape, lawmakers in state after state are anxiously sponsoring legislation eliminating "last-in, first-out" policies. News reports would have people believe every untenured teacher, with just a few months of experience, is a "Teacher of the Year" candidate, while every tenured professional is a money-grabbing, lazy and…
Expertise Increases the Functional Overlap between Face and Object Perception
ERIC Educational Resources Information Center
McKeeff, Thomas J.; McGugin, Rankin W.; Tong, Frank; Gauthier, Isabel
2010-01-01
Recent studies indicate that expertise with objects can interfere with face processing. Although competition occurs between faces and objects of expertise, it remains unclear whether this reflects an expertise-specific bottleneck or the fact that objects of expertise grab attention and thereby consume more central resources. We investigated the…
Legislation Can End Bias against Career Colleges
ERIC Educational Resources Information Center
Miller, Harris N.
2007-01-01
In this article, the author discusses the issue surrounding the blanket rejection of career-school credits by traditional schools. Whether they attend a career college, community college, online college, or brick-and-mortar university, many Americans find that higher education has become a "grab and go" proposition. To them, attending multiple…
Improvements in Store for NCI at Frederick and FNLCR Eateries | Poster
Changes are coming to the Discovery Café on the National Cancer Institute at Frederick campus and to the Grab n’ Go at the Frederick National Laboratory for Cancer Research, improvements that will increase the variety and quantity of food available—and make those enhanced options more accessible.
46 CFR 160.176-4 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... and Elongation, Breaking of Woven Cloth; Grab Method—160.176-13 (2) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method—160.176-13 (3) Method 5134, Strength of Cloth, Tearing; Tongue Method—160.176-13 (4) Method 5804.1, Weathering Resistance of Cloth; Accelerated Weathering Method—160.176-8 (5...
Environmental Stewardship through Service Learning
ERIC Educational Resources Information Center
Kaye, Cathryn Berger
2011-01-01
New school buildings often grab headlines that highlight their green features and LEED (Leadership in Energy and Environmental Design) certification, yet nearly 90% of schools in the United States were built before 1985, with the largest portion built from 1950-69 to accommodate the baby boom generation (National Clearinghouse for Educational…
Creating a Culture of Language Awareness in Content-Based Contexts
ERIC Educational Resources Information Center
Lindahl, Kristen; Watkins, Naomi M.
2015-01-01
A "toolkit" approach to professional development is frequently used to assist teachers of English language learners (ELLs), wherein teachers are provided a grab bag of activities and strategies to implement in their classrooms. However, today's heightened language demands call for teachers to develop teacher language awareness (TLA), a…
ERIC Educational Resources Information Center
Zenchak, John; Lynch, Mary Jean
2011-01-01
The authors developed a demonstration with two similar setups that provide students with both the prior experience to form an expectation and the discrepancy to grab their attention. They follow the demonstration with a structured exploration format that gives students a method for experimenting to find the one built-in difference (i.e., the…
ERIC Educational Resources Information Center
Guhin, Paula
2010-01-01
This article describes an art project designed for middle- and high-school students to (1) understand the meaning of the terms composite and photomontage, and be able to use them correctly; (2) select and evaluate a range of subject matter; (3) combine three different photographs to create an attention-grabbing, entertaining work; and (4) mount…
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Storm rails. 177.920 Section 177.920 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Rails and Guards § 177.920 Storm rails. Suitable storm rails or hand grabs must be...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Storm rails. 177.920 Section 177.920 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Rails and Guards § 177.920 Storm rails. Suitable storm rails or hand grabs must be...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Storm rails. 177.920 Section 177.920 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Rails and Guards § 177.920 Storm rails. Suitable storm rails or hand grabs must be...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Storm rails. 116.920 Section 116.920 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... and Guards § 116.920 Storm rails. Suitable storm rails or hand grabs must be installed where necessary...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Storm rails. 116.920 Section 116.920 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... and Guards § 116.920 Storm rails. Suitable storm rails or hand grabs must be installed where necessary...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Storm rails. 177.920 Section 177.920 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Rails and Guards § 177.920 Storm rails. Suitable storm rails or hand grabs must be...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Storm rails. 116.920 Section 116.920 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... and Guards § 116.920 Storm rails. Suitable storm rails or hand grabs must be installed where necessary...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Storm rails. 177.920 Section 177.920 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Rails and Guards § 177.920 Storm rails. Suitable storm rails or hand grabs must be...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Storm rails. 116.920 Section 116.920 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... and Guards § 116.920 Storm rails. Suitable storm rails or hand grabs must be installed where necessary...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Storm rails. 116.920 Section 116.920 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... and Guards § 116.920 Storm rails. Suitable storm rails or hand grabs must be installed where necessary...
Security: An Emerging Fundamental Value in Educational Policy Making?
ERIC Educational Resources Information Center
DeMitchell, Todd A.
1994-01-01
Education, like other governmental activities, is characterized by a competition for scarce resources. Security, whether in the form of metal detectors or condom availability, is an additional fundamental value that has grabbed center stage in the struggle among competing fundamental values (efficiency, equity, liberty, and quality) in educational…
ERIC Educational Resources Information Center
Jacobs, Paula
2009-01-01
Peter Pistorino says there is a name for the way he thinks a school district should launch an energy conservation initiative: an "envelope" approach. The term refers to looking at the outside package of a structure to check for inefficiencies: Examine the observable, external sources of energy loss such as the doors, windows, insulation,…
Toward a Sociology of Music Curriculum Integration
ERIC Educational Resources Information Center
Bates, Vincent C.
2016-01-01
In this article, an analogy is drawn between processes of land-grabbing or land enclosures and music education professionalization. It is suggested that specializations in musicing and music teaching serve to discourage participation or create musical helplessness on the part of those who don't view themselves as "musically inclined."…
A Probe Intermix Procedure for Fading Response Prompts.
ERIC Educational Resources Information Center
Billingsley, Felix F.
1987-01-01
A prompt fading method was employed to teach an eight-year-old student with severe behavior disorders the self-paced use of a functional behavior (requesting rather than grabbing food items). Initial pairing of prompts and natural cues was followed by a mix of prompted and probe (unprompted) trials. (Author/JW)
Universities Have a Key Role in Global Access to Medicines
ERIC Educational Resources Information Center
Panjabi, Rajesh; Rajkumar, Rahul; Kim, Jim Yong
2008-01-01
Around the world, the fight for affordable medical treatment is intensifying. Headline-grabbing battles are being waged in India, where the Chennai High Court recently decided a major constitutional case over access to lifesaving cancer medication. In Thailand, Abbott Laboratories, a multinational pharmaceutical giant, has withdrawn registration…
Online Learning 2.0: Strategies for a Mature Market
ERIC Educational Resources Information Center
Gallagher, Sean; LaBrie, John
2012-01-01
It is an exciting time for online education. Lately, there has been breathless talk of a "revolution" and massive "disruption," largely based on Massively Open Online Course (MOOC) models pioneered by universities such as MIT and Stanford, and headline-grabbing start-up companies such as Udacity and Coursera. Meanwhile,…
Effectiveness of Breakfast in the Classroom in Five Exemplary Districts
ERIC Educational Resources Information Center
Rainville, Alice Jo; King, Amber D.; Nettles, Mary Frances
2013-01-01
Purpose/Objectives: A national trend to improve school breakfast participation is the integration of breakfast within the school day. Breakfast in the classroom programs increase student access to school breakfast. Service models include "grab and go," distribution of breakfasts to each classroom, and mobile breakfast carts in hallways.…
Exploration of Action Figure Appeals Using Evaluation Grid Method and Quantification Theory Type I
ERIC Educational Resources Information Center
Chang, Hua-Cheng; Chen, Hung-Yuan
2017-01-01
Contemporary toy is characterized by accelerating social, cultural and technological change. An attractive action figure can grab consumers' attention, influence the latent consuming preference and evoke their pleasure. However, traditional design of action figure is always dependent on designer's opinion, subjective experience and preference. It…
Grabbing Third Rails: Courageous Responses to Persistent Equity Gaps
ERIC Educational Resources Information Center
Prystowsky, Richard J.; Herrera, Jordan; Crowley, Cara; Lowery-Hart, Russell; Fannon, Sherri
2017-01-01
Student success efforts often focus on issues related to students' college-readiness, but the authors of a recent book, "Becoming a Student-Ready College: A New Culture of Leadership for Student Success," challenge higher education professionals to take a different approach. The admission of increasingly greater numbers of students from…
ERIC Educational Resources Information Center
Wighting, Mervyn J.
2005-01-01
When Mount St. Helens threatened to erupt again in 2004, it grabbed headlines and captured the imagination of the country. Science classrooms nationwide used the event as an opportunity to make real-world connections to Earth science concepts introduced in the classroom. Thanks to modern technology, teachers no longer have to wait for the next…
Hypersexuality in nursing care facilities--a descriptive study.
Nagaratnam, Nages; Gayagay, George
2002-01-01
The continuance of sexual expression in the elderly as age advances is well recognized. Sexual disinhibition, however, in a restricted environment such as in nursing care facilities has received scant attention. We wish to describe eight patients residing in nursing care facilities who were seen because of their problematic sexually related behaviors. These behaviors include cuddling, touching of the genitals, sexual remarks propositioning, grabbing and groping, use of obscene language and masturbating without shame. In all instances concern emanated from members of the nursing staff. Other associated behaviors included aggression, agitation, and irritability amongst others. The computed tomography (CT) scan of the brain showed infarction in the frontal lobe (4), parietal lobe (1), and the caudate (1). One had severe Parkinson's Disease and one had severe dementia of the Alzheimer's disease. All ten patients had an organic basis for their symptoms. Sexually inappropriate behaviors remain highly controversial and labeling them as 'diseased' or an 'illness' may have enormous individual, cultural and medico-legal implications. The clinico-anatomical correlation are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lear, P.R.; Gemarr, D.
1997-12-31
The US Army Umatilla Depot (UMD) was established as an ordnance depot in 1941 to store, preserve, and perform minor maintenance on conventional and chemical munitions. From the 1940`s until the present, UMD operated periodically at the 32 miscellaneous sites identified as OU-5. OU-4 consists of twenty sites within the Ammunition Demolition Activity Area. Typical activities conducted at these sites consisted of operations to burn, detonate, and otherwise dispose of ordnance, munitions casings, and other solids wastes. Five sites were selected for remedial action. The remediation contaminants of concern for the sites encompassed both metallic and non-metallic elements and bothmore » inorganic and organic compounds. The remedial action selected for the contaminated soil at these sites was stabilization/solidification (S/S). The site remediation activities for the five sites were performed by OHM Remediation Services Corp. (OHM) under the supervision of the US Army Corps of Engineers (USACE) Seattle District. The remedial action included treatability mix design testing, mobilization and field setup, soil excavation and processing, and S/S treatment. Stabilized soil samples were collected as grab samples from the pugmill discharge conveyor at a rate of every 75 tons of soil feed, corresponding to an individual production lot. None of the 437 production lots failed to meet the UCS requirement of 50 psi, however, 31 (7%) of the 437 lots failed for either TCLP-leachable metals or explosives. With one exception, all production lots which failed were due to exceedances of the TCLP-leachable explosives requirements. Of these 30 lots, 22 lots were from the OU-5 metals sites and were not expected to contain significant amounts of explosives. The areas in the landfill corresponding to these lots were excavated and the material reprocessed.« less
Orphan radon daughters at Denver Radium site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holub, R.F.; Droullard, R.F.; Davis, T.H.
During 18 mo of sampling airborne radioactively at a National Priority List ({open_quotes}Superfund{close_quotes}) site in metroPOlitan Denver, Bureau of mines personnel discovered radon daughters that are not supported by the parent radon gas. We refer to them as {open_quotes}orphan{close_quotes} daughters because the parent, radon, is not present in sufficient concentration to support the measured daughter products. Measurements of the {open_quotes}orphan{close_quotes} daughters were made continuously, using the Bureau-developed radon and working-level (radon-daughter) monitors. The data showed high equilibrium ratios, ranging from 0.7 to 3.5, for long periods of time. Repeated, high-volume, 15-min grab samples were made, using the modified Tsivoglou method,more » to measure radon daughters, to which thoron daughters contributed 26 {+-} 12%. On average 28 {+-} 6% of the particulate activity was contributed by thoron daughters. Most samples were mixtures in which the {sup 218}Po concentration was lower than that of {sup 214}Pb and {sup 214}Bi, in agreement with the high-equilibrium factors obtained from the continuous sampling data. In view of the short half-life of radon progeny, we conclude that the source of the orphan daughters is not far from the Superfund sites. The mechanism of this phenomenon is not understood at this time, but we will discuss its possible significance in evaluating population doses.« less
Adaptive measurements of urban runoff quality
NASA Astrophysics Data System (ADS)
Wong, Brandon P.; Kerkez, Branko
2016-11-01
An approach to adaptively measure runoff water quality dynamics is introduced, focusing specifically on characterizing the timing and magnitude of urban pollutographs. Rather than relying on a static schedule or flow-weighted sampling, which can miss important water quality dynamics if parameterized inadequately, novel Internet-enabled sensor nodes are used to autonomously adapt their measurement frequency to real-time weather forecasts and hydrologic conditions. This dynamic approach has the potential to significantly improve the use of constrained experimental resources, such as automated grab samplers, which continue to provide a strong alternative to sampling water quality dynamics when in situ sensors are not available. Compared to conventional flow-weighted or time-weighted sampling schemes, which rely on preset thresholds, a major benefit of the approach is the ability to dynamically adapt to features of an underlying hydrologic signal. A 28 km2 urban watershed was studied to characterize concentrations of total suspended solids (TSS) and total phosphorus. Water quality samples were autonomously triggered in response to features in the underlying hydrograph and real-time weather forecasts. The study watershed did not exhibit a strong first flush and intraevent concentration variability was driven by flow acceleration, wherein the largest loadings of TSS and total phosphorus corresponded with the steepest rising limbs of the storm hydrograph. The scalability of the proposed method is discussed in the context of larger sensor network deployments, as well the potential to improving control of urban water quality.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hudson, L.A.; Ciborowski, J.J.H.; Corkum, L.D.
1995-12-31
The major source of contaminants to the sediments of the western basin of Lake Erie is the Detroit River. In order to determine if contaminant levels are reflected in incidences of genotoxicity of benthic invertebrates, the authors examined larvae of chironomids for mouthpart (mentum) deformities. Sediment genotoxicity is indicated when incidence of deformities in susceptible genera exceeds 5%. Samples were collected from three locations along the contaminant gradient extending from the Detroit River along the main shipping channel of the western basin. A composite sample was taken from several central locations in the western basin. Chironomids were hand-picked from ponarmore » grab or box core samples. The heads were mounted, identified to genus and examined for mentum deformities (extra or missing teeth). Chironomus dominated all samples. The incidence of deformities ({+-}SE) in Chironomus was greatest in the Trenton Channel of the Detroit River (7.8 {+-} 2.2%, n = 153), declined to 5.2 {+-} 1.4% (n = 233) in the center of the basin and was the lowest off East Sister Island (1.9 {+-} 0.9%, n = 210). The incidence of deformities was 4.4 {+-} 0.8% (n = 610) at a reference site on the Canadian side of the Detroit River (Crystal Bay). The spatial pattern of chironomid mentum deformities suggests that sediment genotoxicity declines from west to east in western Lake Erie.« less
Forget, Nathalie L; Kim Juniper, S
2013-01-01
We systematically studied free-living bacterial diversity within aggregations of the vestimentiferan tubeworm Ridgeia piscesae sampled from two contrasting flow regimes (High Flow and Low Flow) in the Endeavour Hydrothermal Vents Marine Protected Area (MPA) on the Juan de Fuca Ridge (Northeast Pacific). Eight samples of particulate detritus were recovered from paired tubeworm grabs from four vent sites. Most sequences (454 tag and Sanger methods) were affiliated to the Epsilonproteobacteria, and the sulfur-oxidizing genus Sulfurovum was dominant in all samples. Gammaproteobacteria were also detected, mainly in Low Flow sequence libraries, and were affiliated with known methanotrophs and decomposers. The cooccurrence of sulfur reducers from the Deltaproteobacteria and the Epsilonproteobacteria suggests internal sulfur cycling within these habitats. Other phyla detected included Bacteroidetes, Actinobacteria, Chloroflexi, Firmicutes, Planctomycetes, Verrucomicrobia, and Deinococcus–Thermus. Statistically significant relationships between sequence library composition and habitat type suggest a predictable pattern for High Flow and Low Flow environments. Most sequences significantly more represented in High Flow libraries were related to sulfur and hydrogen oxidizers, while mainly heterotrophic groups were more represented in Low Flow libraries. Differences in temperature, available energy for metabolism, and stability between High Flow and Low Flow habitats potentially explain their distinct bacterial communities. PMID:23401293
Ahkola, Heidi; Tuominen, Sirkku; Karlsson, Sanja; Perkola, Noora; Huttula, Timo; Saraperä, Sami; Artimo, Aki; Korpiharju, Taina; Äystö, Lauri; Fjäder, Päivi; Assmuth, Timo; Rosendahl, Kirsi; Nysten, Taina
2017-12-01
Anthropogenic chemicals in surface water and groundwater cause concern especially when the water is used in drinking water production. Due to their continuous release or spill-over at waste water treatment plants, active pharmaceutical ingredients (APIs) are constantly present in aquatic environment and despite their low concentrations, APIs can still cause effects on the organisms. In the present study, Chemcatcher passive sampling was applied in surface water, surface water intake site, and groundwater observation wells to estimate whether the selected APIs are able to end up in drinking water supply through an artificial groundwater recharge system. The API concentrations measured in conventional wastewater, surface water, and groundwater grab samples were assessed with the results obtained with passive samplers. Out of the 25 APIs studied with passive sampling, four were observed in groundwater and 21 in surface water. This suggests that many anthropogenic APIs released to waste water proceed downstream and can be detectable in groundwater recharge. Chemcatcher passive samplers have previously been used in monitoring several harmful chemicals in surface and wastewaters, but the path of chemicals to groundwater has not been studied. This study provides novel information on the suitability of the Chemcatcher passive samplers for detecting APIs in groundwater wells.
Carpenter, Corey M G; Helbling, Damian E
2018-06-05
The objective of this study was to identify sources of micropollutants in the Hudson River Estuary (HRE). We collected 127 grab samples at 17 sites along the HRE over 2 years and screened for up to 200 micropollutants. We quantified 168 of the micropollutants in at least one of the samples. Atrazine, gabapentin, metolachlor, and sucralose were measured in every sample. We used data-driven unsupervised methods to cluster the micropollutants on the basis of their spatiotemporal occurrence and normalized-concentration patterns. Three major clusters of micropollutants were identified: ubiquitous and mixed-use (core micropollutants), sourced from sewage treatment plant outfalls (STP micropollutants), and derived from diffuse upstream sources (diffuse micropollutants). Each of these clusters was further refined into subclusters that were linked to specific sources on the basis of relationships identified through geospatial analysis of watershed features. Evaluation of cumulative loadings of each subcluster revealed that the Mohawk River and Rondout Creek are major contributors of most core micropollutants and STP micropollutants and the upper HRE is a major contributor of diffuse micropollutants. These data provide the first comprehensive evaluation of micropollutants in the HRE and define distinct spatiotemporal micropollutant clusters that are linked to sources and conserved across surface water systems around the world.
Klarich, Kathryn L.; Pflug, Nicholas C.; DeWald, Eden M.; Hladik, Michelle L.; Kolpin, Dana W.; Cwiertny, David M.; LeFevre, Gergory H.
2017-01-01
Neonicotinoid insecticides are widespread in surface waters across the agriculturally-intensive Midwestern US. We report for the first time the presence of three neonicotinoids in finished drinking water and demonstrate their general persistence during conventional water treatment. Periodic tap water grab samples were collected at the University of Iowa over seven weeks in 2016 (May-July) after maize/soy planting. Clothianidin, imidacloprid, and thiamethoxam were ubiquitously detected in finished water samples and ranged from 0.24-57.3 ng/L. Samples collected along the University of Iowa treatment train indicate no apparent removal of clothianidin and imidacloprid, with modest thiamethoxam removal (~50%). In contrast, the concentrations of all neonicotinoids were substantially lower in the Iowa City treatment facility finished water using granular activated carbon (GAC) filtration. Batch experiments investigated potential losses. Thiamethoxam losses are due to base-catalyzed hydrolysis at high pH conditions during lime softening. GAC rapidly and nearly completely removed all three neonicotinoids. Clothianidin is susceptible to reaction with free chlorine and may undergo at least partial transformation during chlorination. Our work provides new insights into the persistence of neonicotinoids and their potential for transformation during water treatment and distribution, while also identifying GAC as an effective management tool to lower neonicotinoid concentrations in finished drinking water.
Rochelle-Newall, Emma J.; Ribolzi, Olivier; Viguier, Marion; Thammahacksa, Chanthamousone; Silvera, Norbert; Latsachack, Keooudone; Dinh, Rinh Pham; Naporn, Piyapong; Sy, Hai Tran; Soulileuth, Bounsamay; Hmaimum, Nikom; Sisouvanh, Pem; Robain, Henri; Janeau, Jean-Louis; Valentin, Christian; Boithias, Laurie; Pierret, Alain
2016-01-01
Lack of access to clean water and adequate sanitation continues to be a major brake on development. Here we present the results of a 12-month investigation into the dynamics of Escherichia coli, a commonly used indicator of faecal contamination in water supplies, in three small, rural catchments in Laos, Thailand and Vietnam. We show that land use and hydrology are major controlling factors of E. coli concentrations in streamwater and that the relative importance of these two factors varies between the dry and wet seasons. In all three catchments, the highest concentrations were observed during the wet season when storm events and overland flow were highest. However, smaller peaks of E. coli concentration were also observed during the dry season. These latter correspond to periods of intense farming activities and small, episodic rain events. Furthermore, vegetation type, through land use and soil surface crusting, combined with mammalian presence play an important role in determining E. coli loads in the streams. Finally, sampling during stormflow revealed the importance of having appropriate sampling protocols if information on maximum contamination levels is required as grab sampling at a fixed time step may miss important peaks in E. coli numbers. PMID:27604854
Methods and Metrics for Evaluating Environmental Dredging ...
This report documents the objectives, approach, methodologies, results, and interpretation of a collaborative research study conducted by the National Risk Management Research Laboratory (NRMRL) and the National Exposure Research laboratory (NERL) of the U.S. Environmental Protection Agency’s (U.S. EPA’s) Office of Research and Development (ORD) and the U.S. EPA’s Great Lakes National Program Office (GLNPO). The objectives of the research study were to: 1) evaluate remedy effectiveness of environmental dredging as applied to contaminated sediments in the Ashtabula River in northeastern Ohio, and 2) monitor the recovery of the surrounding ecosystem. The project was carried out over 6 years from 2006 through 2011 and consisted of the development and evaluation of methods and approaches to assess river and ecosystem conditions prior to dredging (2006), during dredging (2006 and 2007), and following dredging, both short term (2008) and long term (2009-2011). This project report summarizes and interprets the results of this 6-year study to develop and assess methods for monitoring pollutant fate and transport and ecosystem recovery through the use of biological, chemical, and physical lines of evidence (LOEs) such as: 1) comprehensive sampling of and chemical analysis of contaminants in surface, suspended, and historic sediments; 2) extensive grab and multi-level real time water sampling and analysis of contaminants in the water column; 3) sampling, chemi
Evaluation Of Water Quality At River Bian In Merauke Papua
NASA Astrophysics Data System (ADS)
Djaja, Irba; Purwanto, P.; Sunoko, H. R.
2018-02-01
River Bian in Merauke Regency has been utilized by local people in Papua (the Marind) who live along the river for fulfilling their daily needs, such as shower, cloth and dish washing, and even defecation, waste disposal, including domestic waste, as well as for ceremonial activities related to the locally traditional culture. Change in land use for other necessities and domestic activities of the local people have mounted pressures on the status of the River Bian, thus decreasing the quality of the river. This study had objectives to find out and to analyze river water quality and water quality status of the River Bian, and its compliance with water quality standards for ideal use. The study determined sample point by a purposive sampling method, taking the water samples with a grab method. The analysis of the water quality was performed by standard and pollution index methods. The study revealed that the water quality of River Bian, concerning BOD, at the station 3 had exceeded quality threshold. COD parameter for all stations had exceeded the quality threshold for class III. At three stations, there was a decreasing value due to increasing PI, as found at the stations 1, 2, and 3. In other words, River Bian had been lightly contaminated.
Gaspard, Philippe G; Schwartzbrod, Janine
2003-03-01
The use of sludge in agriculture must be carried out according to many guidelines, especially regarding a precise knowledge of the pathogenic microorganisms it contains. The control of the produced sludge requires a sampling strategy that is representative of the contamination present in the sludge. Thus, we evaluated the distribution of helminth eggs in sludge to determine how to sample and at what frequency. Two plants were studied, firstly we studied sludge that was undergoing biological treatment (anaerobic digestion, prolonged aeration), secondly we evaluated the dehydration step (centrifugation and filter press). The helminth egg concentrations were measured over short periods (between 5 minutes and 7 hours) and for periods of over 24 hours (7 to 28 days). The results showed that there was much homogeneity in periods of less than 7 hours, thus it was advisable to take grab samples. An appropriate sample weight was 30 g dry matter, because this allowed an analysis in triplicate when testing treatment processes according to standards of France, (less than 3 viable eggs/10 g dry matter). Determination of the egg concentration in the plants during periods of over 24 hours showed that the parasite flow was stable. In some cases, large variations were due to the treatment processes (storage or thickening, mixing of different sludges). These results have been confirmed with the study of 6 other plants during a one year period. Thus, the recommended sampling frequency can be limited to every 3 to 6 months, by adapting the sampling methods to the characteristics of the plant.
Nonlinear effects of group size on the success of wolves hunting elk
MacNulty, D.R.; Smith, D.W.; Mech, L.D.; Vucetich, J.A.; Packer, C.
2012-01-01
Despite the popular view that social predators live in groups because group hunting facilitates prey capture, the apparent tendency for hunting success to peak at small group sizes suggests that the formation of large groups is unrelated to prey capture. Few empirical studies, however, have tested for nonlinear relationships between hunting success and group size, and none have demonstrated why success trails off after peaking. Here, we use a unique dataset of observations of individually known wolves (Canis lupus) hunting elk (Cervus elaphus) in Yellowstone National Park to show that the relationship between success and group size is indeed nonlinear and that individuals withholding effort (free riding) is why success does not increase across large group sizes. Beyond 4 wolves, hunting success leveled off, and individual performance (a measure of effort) decreased for reasons unrelated to interference from inept hunters, individual age, or size. But performance did drop faster among wolves with an incentive to hold back, i.e., nonbreeders with no dependent offspring, those performing dangerous predatory tasks, i.e., grabbing and restraining prey, and those in groups of proficient hunters. These results suggest that decreasing performance was free riding and that was why success leveled off in groups with >4 wolves that had superficially appeared to be cooperating. This is the first direct evidence that nonlinear trends in group hunting success reflect a switch from cooperation to free riding. It also highlights how hunting success per se is unlikely to promote formation and maintenance of large groups. ?? 2011 The Author.
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeRosier, R.; Waterland, L.R.
1986-02-01
The report describes results from field testing a watertube industrial boiler firing a coal/water slurry (CWS) containing about 60% coal. Emission measurements included continuous monitoring of flue-gas emissions; source assessment sampling system (SASS) sampling of the flue-gas, with subsequent analysis of samples to obtain total flue-gas organics in two boiling point ranges, compound category information within these ranges, specific quantitation of the semivolatile organic priority pollutants, and flue-gas concentrations of 73 trace elements: EPA Methods 5/8 sampling for particulate, SO/sub 2/, and SO/sub 3/ emissions; and grab sampling of fuel and ash for inorganic composition. NOx, SO/sub 2/, CO, andmore » TUHC emissions were in the 230-310, 880-960, 170-200, and 1-3 ppm ranges (corrected to 3% 02), respectively, over the two tests performed. Particulate levels at the boiler outlet (upstream of the unit's baghouse) were 7.3 g/dscm in the comprehensive test. Coarse particulate (>3 micrometers) predominated. Total organic emissions were almost 50 mg/dscm, with about 70% of the organic matter in the nonvolatile (>300 C) boiling point range. The bottom ash organic content was 8 mg/g, 80% of which was in the nonvolatile range. Of the PAHs, only naphthalene was detected in the flue gas particulate, with emission levels of 8.6 micrograms/dscm. Several PAHs were found in the bottom ash.« less
Turbidity and suspended sediment in the upper Esopus Creek watershed, Ulster County, New York
McHale, Michael R.; Siemion, Jason
2014-01-01
Discharge, SSC, and turbidity were strongly related at the Coldbrook site but not at every monitoring site. In general, relations between discharge and SSC and turbidity were strongest at sites with high SSCs, with the exception of Stony Clove Creek. Stony Clove Creek had high SSCs and turbidity regardless of discharge, and although concentrations and turbidity values generally increased with increasing discharge, the relation was not strong. Five of the six sites used to investigate the relations between SSC and laboratory turbidity had a coefficient of determination (r2) greater than 0.7. Relations were not as strong between SSC and the turbidity measured by in situ probes because the period of record was shorter and therefore the sample sizes were smaller. Data from in situ turbidity probes were strongly related to turbidity data measured in the laboratory for all but one of the monitoring sites where the relation was strongly leveraged by one sample. Although the in situ turbidity probes appeared to provide a good surrogate for SSC and could allow more accurate calculations of suspended-sediment load than discrete suspended-sediment samples alone, more data would be required to define the regression models throughout the range in discharge, SSCs, and turbidity levels that occur at each monitoring site. Nonetheless, the in situ probes provided much greater detail about the relation between discharge and turbidity than did the grab samples and storm samples measured in the laboratory.
Game, Water, and People Up for Grabs: A Review Essay.
ERIC Educational Resources Information Center
Keller, Robert H.
1979-01-01
This article asserts if Americans continue to pump, mine and extract natural resources they will inevitably confront the harsh but intractable facts of nature, and that a salvageable future must be one of limits, of new social controls and of recovering an old ethic which honors foresight, forebearance and sharing. (Author/RTS)
Integrating the Curriculum: Faux Fall Repousse
ERIC Educational Resources Information Center
Kernan, Christine
2012-01-01
When introducing a new unit, art teachers know that sometimes a little "bling" can really grab students' attention. The author received "ooohs" and "aaahs" from her fourth-graders when they learned they would be creating "Faux Fall Repousse." The dazzling shine of the aluminum foil and the beautiful array of autumnal colors were impossible for…
ERIC Educational Resources Information Center
Mackay-Atha, Lynne
2005-01-01
When students enter the author's classroom on the first day of school, they are greeted with live crabs scuttling around in large bins. The crabs are her way of grabbing students' attention and launching the unit on the Chesapeake Bay watershed. She chooses to start the year with this unit because, despite the fact that the Potomac River can be…
... part of the foot is similar to the hand, with five bones. Each toe has three tiny bones, except for your big toe, which has just two. This brings the bone total in both feet and ankles to 52! Most people don't use their toes and feet for grabbing stuff or writing, but they do use them for two very ...
Russian Artic Strategy: Or How I Learned to Stop Worrying and Love Bureaucratic Politics
a land grab, during both periods Russia has pursued an economic calculation strategy, attempting to maintain a benign political environment while at...the same time steering the Arctic energy and transport sectors for the purpose of reaping economic rewards. The continuity noted in Russias strategy is
ERIC Educational Resources Information Center
Diverse: Issues in Higher Education, 2006
2006-01-01
"Summers To Step Down, Ending Tumult at Harvard" kicked off in 2006 as one of the most talked about news stories in higher education. Only a few months later, an event involving another elite institution would grab even more headlines, and with more serious ramifications. Three Duke University men's lacrosse players were indicted on rape…
29 CFR 1917.16 - Line handling. (See also § 1917.95(b)).
Code of Federal Regulations, 2011 CFR
2011-07-01
... also § 1917.95(b)). (a) In order to provide safe access for handling lines while mooring and unmooring... be used. (b) When stringpiece or apron width is insufficient for safe footing, grab lines or rails... the water edge of a berth and a shed or other structure.) ...
29 CFR 1917.16 - Line handling. (See also § 1917.95(b)).
Code of Federal Regulations, 2010 CFR
2010-07-01
... also § 1917.95(b)). (a) In order to provide safe access for handling lines while mooring and unmooring... be used. (b) When stringpiece or apron width is insufficient for safe footing, grab lines or rails... the water edge of a berth and a shed or other structure.) ...
474 Science Activities for Young Children.
ERIC Educational Resources Information Center
Green, Moira D.
This book uses a child-initiated, whole language approach to help children have fun while exploring the world of science. The activities are divided into 23 units. Each unit begins with an "Attention Getter," the purpose of which is to introduce the unit to children in a way that grabs their attention, stimulates their interest, and creates…
Grab a Great Resource: Using Educational Resources in the Community.
ERIC Educational Resources Information Center
Northern Illinois Univ., De Kalb.
A guide to teaching resources in three northern Illinois counties was created by 28 teachers in a graduate course entitled "Integrating Community Resources into Curriculum and Instruction." The first part of the guide provides contact information and a brief description for approximately 100 people, places, and things that could be…
General Christopher C. Andrews: Leading the Minnesota Forestry Revolution
ERIC Educational Resources Information Center
Rice, Anna M.
2002-01-01
In the nineteenth century, America's burgeoning population certainly did grab all the timber it could. Vast pine forests stretched from Maine to Dakota, and the lumber industry voraciously consumed them from east to west. In 1800, the Minnesota territory was sparsely sprinkled with fur traders and American Indians. By 1850, its bounteous forests…
ERIC Educational Resources Information Center
Johnson, Richard W.; Southgate, Benjamin G.
2014-01-01
The financial problems afflicting the Illinois teacher pension plan have grabbed headlines. An equally important problem, though underappreciated, is that relatively few teachers benefit much from the plan. This report evaluates the pension benefits provided to Illinois public school teachers. The researchers project annual and lifetime pension…
Secrets in Full View: Sexual Harassment in Our K-12 Schools.
ERIC Educational Resources Information Center
Stein, Nan
Sexual harassment can range from touching, tickling, pinching, patting, or grabbing; to comments about one's body; to sexual remarks, innuendoes, and jokes that cause discomfort; to obscene gestures, staring, or leering; to assault and rape. This paper addresses student testimonies of harassment, provides a profile of harassment behaviors, and…
ERIC Educational Resources Information Center
Sorenson, Richard D.
2007-01-01
Administrative power for some school teachers can be an aphrodisiac that can be applied negatively, especially when a leader has devastating instinct for the weaknesses of others. A leader's intellect and heart closes shop and ceases to function when drunk on power. In this article, the author describes how the use of administrative power can be…
Simple Ways to Make Real Capacitors
ERIC Educational Resources Information Center
Herman, Rhett
2014-01-01
Many of us have grabbed two pieces of aluminum foil and a paper towel, quickly sandwiched them together, and exclaimed in lecture, "Look! It's easy to make a capacitor!" Then we move on from there, calculating things such as capacitances with various dielectrics or plate sizes, the capacitance of capacitor networks, RC circuits,…
ERIC Educational Resources Information Center
Sapp, Gregg
2010-01-01
Science often reflects society's concerns, and a number of the top books of 2009 address two of the biggest headline-grabbing topics--climate change and health-care reform. This article presents a list of 35 titles that address climate change and health-care reform. Some titles cover the entirety of the global-warming threat (James Lovelock's "The…
Fab Web Sites on the 2008 Presidential Election
ERIC Educational Resources Information Center
Langhorst, Eric
2008-01-01
Teachers live for the "teachable moments"--those opportunities to connect their subject content to events taking place beyond the classroom. They can occur spontaneously, lucky occasions to bring the curriculum to life grabbed on the fly. In other instances, a teachable moment looms large. In hundreds of thousands of classrooms nationwide,…
Engage and Excite Students with Educational Games
ERIC Educational Resources Information Center
Petsche, Jennifer
2011-01-01
Using educational games to learn or reinforce lessons engages students and turns a potentially boring subject into something exciting and desirable to know! Games offer teachers and parents a new way to grab students' attention so that they will retain information. Games have become a teaching tool, an invaluable resource for reaching students in…
NAEP and Policy: Chasing the Tail of the Assessment Tiger
ERIC Educational Resources Information Center
Diket, Read M.; Brewer, Thomas M.
2011-01-01
This paper grabs hold of the "assessment tiger" by considering the history of the National Assessment of Educational Progress (NAEP) "Arts Report Cards" for the visual arts, which were constructed and have been administered four times within thirty-five years. Two purposes of the NAEP have persisted since its founding: (1)…
2008-07-01
others much larger - have developed into mini-American towns.On some bases, troops fresh off of a patrol can stroll in for a sandwich at a makeshift... Subway , grab a pie at Pizza Hut or get a Whopper from Burger King. QuickTime™ and a decompressor are needed to see this picture. Even in the chow
Teaching Bayesian Statistics to Undergraduate Students through Debates
ERIC Educational Resources Information Center
Stewart, Sepideh; Stewart, Wayne
2014-01-01
This paper describes a lecturer's approach to teaching Bayesian statistics to students who were only exposed to the classical paradigm. The study shows how the lecturer extended himself by making use of ventriloquist dolls to grab hold of students' attention and embed important ideas in revealing the differences between the Bayesian and classical…
School Bus Safety: What Can Our Schools Do to Protect Our Children?
ERIC Educational Resources Information Center
Dargan, Thomas J.; Silverstone, Adam H.
2014-01-01
School districts and school bus contractors are entrusted with the most important of all road users--our nation's children. In the wake of recent newsworthy accidents and attention grabbing headlines regarding unfit bus drivers, claims premised upon school bus accidents have become increasingly tangential and, in turn, personal injury attorneys…
With "Restorative Justice," Colleges Strive to Educate Student Offenders
ERIC Educational Resources Information Center
Lipka, Sara
2009-01-01
Student-conduct administrators around the country are hailing restorative justice as the next big thing. A blend of mediation and restitution, it seeks to resolve a conflict by identifying the harms caused and devising, with suggestions from both victims and offenders, an agreement to repair them. That approach to discipline grabs campus officials…
Foveal vs. parafoveal attention-grabbing power of threat-related information.
Calvo, Manuel G; Castillo, M Dolores
2005-01-01
We investigated whether threat words presented in attended (foveal) and in unattended (parafoveal) locations of the visual field are attention grabbing. Neutral (nonemotional) words were presented at fixation as probes in a lexical decision task. Each probe word was preceded by 2 simultaneous prime words (1 foveal, 1 parafoveal), either threatening or neutral, for 150 ms. The stimulus onset asynchrony (SOA) between the primes and the probe was either 300 or 1,000 ms. Results revealed slowed lexical decision times on the probe when primed by an unrelated foveal threat word at the short (300-ms) delay. In contrast, parafoveal threat words did not affect processing of the neutral probe at either delay. Nevertheless, both neutral and threat parafoveal words facilitated lexical decisions for identical probe words at 300-ms SOA. This suggests that threat words appearing outside the focus of attention do not draw or engage cognitive resources to such an extent as to produce interference in the processing of concurrent or subsequent neutral stimuli. An explanation of the lack of parafoveal interference is that semantic content is not extracted in the parafovea.
Liu, Jian; Liang, Huawei; Wang, Zhiling; Chen, Xiangcheng
2015-01-01
The quick and accurate understanding of the ambient environment, which is composed of road curbs, vehicles, pedestrians, etc., is critical for developing intelligent vehicles. The road elements included in this work are road curbs and dynamic road obstacles that directly affect the drivable area. A framework for the online modeling of the driving environment using a multi-beam LIDAR, i.e., a Velodyne HDL-64E LIDAR, which describes the 3D environment in the form of a point cloud, is reported in this article. First, ground segmentation is performed via multi-feature extraction of the raw data grabbed by the Velodyne LIDAR to satisfy the requirement of online environment modeling. Curbs and dynamic road obstacles are detected and tracked in different manners. Curves are fitted for curb points, and points are clustered into bundles whose form and kinematics parameters are calculated. The Kalman filter is used to track dynamic obstacles, whereas the snake model is employed for curbs. Results indicate that the proposed framework is robust under various environments and satisfies the requirements for online processing. PMID:26404290
Land grabbing: a preliminary quantification of economic impacts on rural livelihoods.
Davis, Kyle F; D'Odorico, Paolo; Rulli, Maria Cristina
2014-01-01
Global demands on agricultural land are increasing due to population growth, dietary changes and the use of biofuels. Their effect on food security is to reduce humans' ability to cope with the uncertainties of global climate change. In light of the 2008 food crisis, to secure reliable future access to sufficient agricultural land, many nations and corporations have begun purchasing large tracts of land in the global South, a phenomenon deemed "land grabbing" by popular media. Because land investors frequently export crops without providing adequate employment, this represents an effective income loss for local communities. We study 28 countries targeted by large-scale land acquisitions [comprising 87 % of reported cases and 27 million hectares (ha)] and estimate the effects of such investments on local communities' incomes. We find that this phenomenon can potentially affect the incomes of ~12 million people globally with implications for food security, poverty levels and urbanization. While it is important to note that our study incorporates a number of assumptions and limitations, it provides a much needed initial quantification of the economic impacts of large-scale land acquisitions on rural livelihoods.
Navarro-Sanchez, Erika; Altmeyer, Ralf; Amara, Ali; Schwartz, Olivier; Fieschi, Franck; Virelizier, Jean-Louis; Arenzana-Seisdedos, Fernando; Desprès, Philippe
2003-01-01
Dengue virus (DV) is a mosquito-borne flavivirus that causes haemorrhagic fever in humans. DV primarily targets immature dendritic cells (DCs) after a bite by an infected mosquito vector. Here, we analysed the interactions between DV and human-monocyte-derived DCs at the level of virus entry. We show that the DC-specific ICAM3-grabbing non-integrin (DC-SIGN) molecule, a cell-surface, mannose-specific, C-type lectin, binds mosquito-cell-derived DVs and allows viral replication. Conclusive evidence for the involvement of DC-SIGN in DV infection was obtained by the inhibition of viral infection by anti-DC-SIGN antibodies and by the soluble tetrameric ectodomain of DC-SIGN. Our data show that DC-SIGN functions as a DV-binding lectin by interacting with the DV envelope glycoprotein. Mosquito-cell-derived DVs may have differential infectivity for DC-SIGN-expressing cells. We suggest that the differential use of DC-SIGN by viral envelope glycoproteins may account for the immunopathogenesis of DVs. PMID:12783086
Multiresolution saliency map based object segmentation
NASA Astrophysics Data System (ADS)
Yang, Jian; Wang, Xin; Dai, ZhenYou
2015-11-01
Salient objects' detection and segmentation are gaining increasing research interest in recent years. A saliency map can be obtained from different models presented in previous studies. Based on this saliency map, the most salient region (MSR) in an image can be extracted. This MSR, generally a rectangle, can be used as the initial parameters for object segmentation algorithms. However, to our knowledge, all of those saliency maps are represented in a unitary resolution although some models have even introduced multiscale principles in the calculation process. Furthermore, some segmentation methods, such as the well-known GrabCut algorithm, need more iteration time or additional interactions to get more precise results without predefined pixel types. A concept of a multiresolution saliency map is introduced. This saliency map is provided in a multiresolution format, which naturally follows the principle of the human visual mechanism. Moreover, the points in this map can be utilized to initialize parameters for GrabCut segmentation by labeling the feature pixels automatically. Both the computing speed and segmentation precision are evaluated. The results imply that this multiresolution saliency map-based object segmentation method is simple and efficient.
iGrab: hand orthosis powered by twisted and coiled polymer muscles
NASA Astrophysics Data System (ADS)
Saharan, Lokesh; de Andrade, Monica Jung; Saleem, Wahaj; Baughman, Ray H.; Tadesse, Yonas
2017-10-01
Several works have been reported in powered hand orthosis in the last ten years for assistive or rehabilitative purposes. However, most of these approaches uses conventional actuators such as servo motors to power orthosis. In this work, we demonstrate the recently reported twisted and coiled polymeric (TCP) muscles to drive a compact, light, inexpensive and wearable upper extremity device, iGrab. A 3D printed orthotic hand module was designed, developed and tested for the performance. The device has six 2-ply muscles of diameter 1.35 mm with a length of 380 mm. We used a single 2-ply muscle for each finger and two 2-ply muscles for the thumb. Pulsed actuation of the muscles at 1.8 A current for 25 s with 7% duty cycle under natural cooling showed full flexion of the fingers within 2 s. Modeling and simulation were performed on the device using standard Euler-Lagrangian equations. Our artificial muscles powered hand orthosis demonstrated the capability of pinching and picking objects of different shapes, weights, and sizes.
Mehta, Dipakkumar; Kumar, M H Sathish; Sabikhi, Latha
2017-11-01
The current work aimed to formulate smoothie by optimizing varying levels of soy protein isolate (1.5-2.5% w/w), sucralose (150-190 ppm) and pectin (0.3-0.5% w/w) along with milk, legume (chickpea), vegetable (carrot), fruit (mango), honey and trisodium citrate by response surface methodology on the basis of sensory (color and appearance, flavor, consistency, sweetness and overall acceptability) and physical (expressible serum and viscosity) responses. Soy protein isolate and pectin levels influenced color and appearance, flavor, consistency and overall acceptability significantly. Soy protein isolate and pectin showed a positive correlation with viscosity of smoothie with reduced expressible serum. Smoothie was optimized with 1.8% (w/w) soy protein isolate, 166.8 ppm sucralose, and 0.5% (w/w) pectin with acceptable quality. One serving (325 ml) of optimized smoothie provides approximately 23% protein, 27% dietary fiber of the recommended daily values and provides approximately 74 kcal per 100 ml of smoothie, which renders smoothie as a high protein, high fiber, grab-and-go breakfast option.
Coes, Alissa L.; Paretti, Nicholas V.; Foreman, William T.; Iverson, Jana L.; Alvarez, David A.
2014-01-01
A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19–23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method.
Coes, Alissa L; Paretti, Nicholas V; Foreman, William T; Iverson, Jana L; Alvarez, David A
2014-03-01
A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19-23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method. Published by Elsevier B.V.
MONITORING OF WATERWAYS FOR EMERGING ...
Assessing the potential impact to the aquatic environment from emerging contaminants, entails monitoring a complex mixture (pharmaceuticals, polar pesticides, industrial by- products and degradation products) in natural waters. The presence of these chemicals, often at ultra-trace levels, may be responsible for development of sub-lethal toxic effects in aquatic organisms (i.e., reproductive dysfunction, immune dysfunction, neurological disorders). Conventional sampling techniques (i.e., grab sampling) often are insufficient for detecting these trace levels. An integrative sampler, the Polar Organic Chemical Integrative Sampler (POCIS), developed by the USGS Columbia Environmental Research Center, provided a way to measure the time-weighted average concentrations of these complex mixtures of contaminants. When POCIS was combined with liquid chromatography/mass spectrometry (LC/MS), it proved to be a powerful tool in identification and quantification of polar anthropogenic contaminants. Data from a pilot study showed the antibiotic azithromycin, illicit drugs [methamphetamine and MDMA (Ecstasy)], polyfluorinated organic acids (PFOA and PFOS) (essential ingredients in the manufacture of fluoropolymers), and surfactants [i.e., diethanolamine polyethylene glycols (DAPGs), polyethylene glycols (PEGs), and nonylphenol ethoxylates (NPEOs)] were all present in the extracts from the effluents of three wastewater treatment plants and other bodies of natural waters. Althoug
Kukreti, B M; Pandey, Pradeep; Singh, R V
2012-08-01
Non-coring based exploratory drilling was under taken in the sedimentary environment of Rangsohkham block, East Khasi Hills district to examine the eastern extension of existing uranium resources located at Domiasiat and Wakhyn in the Mahadek basin of Meghalaya (India). Although radiometric survey and radiometric analysis of surface grab/channel samples in the block indicate high uranium content but the gamma ray logging results of exploratory boreholes in the block, did not obtain the expected results. To understand this abrupt discontinuity between the two sets of data (surface and subsurface) multivariate statistical analysis of primordial radioactive elements (K(40), U(238) and Th(232)) was performed using the concept of representative subsurface samples, drawn from the randomly selected 11 boreholes of this block. The study was performed to a high confidence level (99%), and results are discussed for assessing the U and Th behavior in the block. Results not only confirm the continuation of three distinct geological formations in the area but also the uranium bearing potential in the Mahadek sandstone of the eastern part of Mahadek Basin. Copyright © 2012 Elsevier Ltd. All rights reserved.