Sample records for indoor environment program

  1. i-SVOC -- A simulation program for indoor SVOCs (Version 1.0)

    EPA Science Inventory

    Program i-SVOC estimates the emissions, transport, and sorption of semivolatile organic compounds (SVOCs) in the indoor environment as functions of time when a series of initial conditions is given. This program implements a framework for dynamic modeling of indoor SVOCs develope...

  2. Indoor environment program. 1994 annual report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daisey, J.M.

    1995-04-01

    Buildings use approximately one-third of the energy consumed in the United States. The potential energy savings derived from reduced infiltration and ventilation in buildings are substantial, since energy use associated with conditioning and distributing ventilation air is about 5.5 EJ per year. However, since ventilation is the dominant mechanism for removing pollutants from indoor sources, reduction of ventilation can have adverse effects on indoor air quality, and on the health, comfort, and productivity of building occupants. The Indoor Environment Program in LBL`s Energy and Environment Division was established in 1977 to conduct integrated research on ventilation, indoor air quality, andmore » energy use and efficiency in buildings for the purpose of reducing energy liabilities associated with airflows into, within, and out of buildings while maintaining or improving occupant health and comfort. The Program is part of LBL`s Center for Building Science. Research is conducted on building energy use and efficiency, ventilation and infiltration, and thermal distribution systems; on the nature, sources, transport, transformation, and deposition of indoor air pollutants; and on exposure and health risks associated with indoor air pollutants. Pollutants of particular interest include radon; volatile, semivolatile, and particulate organic compounds; and combustion emissions, including environmental tobacco smoke, CO, and NO{sub x}.« less

  3. Negotiating safety and sexual risk reduction with clients in unsanctioned safer indoor sex work environments: a qualitative study.

    PubMed

    Krüsi, Andrea; Chettiar, Jill; Ridgway, Amelia; Abbott, Janice; Strathdee, Steffanie A; Shannon, Kate

    2012-06-01

    We examined how unique, low-barrier, supportive housing programs for women who are functioning as unsanctioned indoor sex work environments in a Canadian urban setting influence risk negotiation with clients in sex work transactions. We conducted 39 semistructured qualitative interviews and 6 focus groups with women who live in low-barrier, supportive housing for marginalized sex workers with substance use issues. All interviews were transcribed verbatim and thematically analyzed. Women's accounts indicated that unsanctioned indoor sex work environments promoted increased control over negotiating sex work transactions, including the capacity to refuse unwanted services, negotiate condom use, and avoid violent perpetrators. Despite the lack of formal legal and policy support for indoor sex work venues in Canada, the environmental-structural supports afforded by these unsanctioned indoor sex work environments, including surveillance cameras and support from staff or police in removing violent clients, were linked to improved police relationships and facilitated the institution of informal peer-safety mechanisms. This study has drawn attention to the potential role of safer indoor sex work environments as venues for public health and violence prevention interventions and has indicated the critical importance of removing the sociolegal barriers preventing the formal implementation of such programs.

  4. Negotiating Safety and Sexual Risk Reduction With Clients in Unsanctioned Safer Indoor Sex Work Environments: A Qualitative Study

    PubMed Central

    Krüsi, Andrea; Chettiar, Jill; Ridgway, Amelia; Abbott, Janice; Strathdee, Steffanie A.

    2012-01-01

    Objectives. We examined how unique, low-barrier, supportive housing programs for women who are functioning as unsanctioned indoor sex work environments in a Canadian urban setting influence risk negotiation with clients in sex work transactions. Methods. We conducted 39 semistructured qualitative interviews and 6 focus groups with women who live in low-barrier, supportive housing for marginalized sex workers with substance use issues. All interviews were transcribed verbatim and thematically analyzed. Results. Women’s accounts indicated that unsanctioned indoor sex work environments promoted increased control over negotiating sex work transactions, including the capacity to refuse unwanted services, negotiate condom use, and avoid violent perpetrators. Despite the lack of formal legal and policy support for indoor sex work venues in Canada, the environmental-structural supports afforded by these unsanctioned indoor sex work environments, including surveillance cameras and support from staff or police in removing violent clients, were linked to improved police relationships and facilitated the institution of informal peer-safety mechanisms. Conclusions. This study has drawn attention to the potential role of safer indoor sex work environments as venues for public health and violence prevention interventions and has indicated the critical importance of removing the sociolegal barriers preventing the formal implementation of such programs. PMID:22571708

  5. AN OVERVIEW OF INDOOR RADON RISK REDUCTION IN THE UNITED STATES

    EPA Science Inventory

    Radon in the indoor environment is a recognized environmental hazard. The Environmental Protection Agency (EPA) has established several programs to develop, demonstrate, and transfer radon mitigation technology. Administration and management of these programs are shared by EPA's ...

  6. 40 CFR 35.700 - Purpose.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Environmental Program Grants for Tribes Indoor Radon Grants (section 306) § 35.700 Purpose. (a... programs that assess and mitigate radon and that aim at reducing radon health risks. Indoor Radon Grant...

  7. 40 CFR 61.205 - Distribution and use of phosphogypsum for indoor research and development.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... for indoor research and development. 61.205 Section 61.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR... and use of phosphogypsum for indoor research and development. (a) Phosphogypsum may be lawfully...

  8. 40 CFR 61.205 - Distribution and use of phosphogypsum for indoor research and development.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... for indoor research and development. 61.205 Section 61.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR... and use of phosphogypsum for indoor research and development. (a) Phosphogypsum may be lawfully...

  9. Indoor Air Quality Tools for Schools Program: Benefits of Improving Air Quality in the School Environment.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Office of Radiation and Indoor Air.

    The U.S. Environmental Protection Agency (EPA) developed the Indoor Air Quality Tools for Schools (IAQ TfS) Program to help schools prevent, identify, and resolve their IAQ problems. This publication describes the program and its advantages, explaining that through simple, low-cost measures, schools can: reduce IAQ-related health risks and…

  10. Breathing In

    ERIC Educational Resources Information Center

    Mahoney, Daniel P.

    2008-01-01

    Healthful indoor air quality (IAQ) in education facilities can improve the learning environment for students, enhance teacher job satisfaction, and reduce staff complaints. A proactive indoor air quality program helps identify and eliminate conditions that could lead to IAQ complaints, building-related illnesses, and workers' compensation claims.…

  11. NIOSH testimony on indoor air quality: Selected references before the Subcommittee on Superfund, Ocean and Water Protection, Committee on Environment and Public Works, United States Senate by J. Donald Millar, May 26, 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1989-09-01

    The National Institute for Occupational Safety and Health (NIOSH) has compiled the document in response to an increasing number of requests for information about indoor air quality (IAQ), including sick building syndrome. Included in the publication are: NIOSH Congressional testimony that describes the NIOSH IAQ investigations program and summarizes the results of NIOSH research and findings on IAQ problems, NIOSH guidance for conducting indoor air quality investigations, NIOSH journal article on evaluating building ventilation systems, and list of non-NIOSH publications on indoor air quality. As the Federal agency responsible for conducting research and making recommendations for occupational safety and healthmore » standards, NIOSH limits its IAQ activities to the occupational environment. The U.S. Environmental Protection Agency (EPA) also conducts an IAQ program and can be contacted for information regarding both occupational and non-occupational settings.« less

  12. 40 CFR 35.290 - Purpose.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Environmental Program Grants State Indoor Radon Grants (section 306) § 35.290 Purpose. (a) Purpose... mitigate radon and that aim at reducing radon health risks. State Indoor Radon Grant funds may be used for...

  13. Installation of PMV Operation Program in DDC Controller and Air Conditioning Control Using PMV Directly as Set Point

    NASA Astrophysics Data System (ADS)

    Haramoto, Ken-Ichi

    In general, air conditioning control in a building is operated mainly by indoor air temperature control. Although the operators of the machine in the building accepted a claim for indoor air temperature presented by the building inhabitants, the indoor conditions have been often too cool or warm. Therefore, in an attempt to create better thermal environments, the author paid attention to the PMV that is a thermal comfort index. And then, the possibility of air conditioning control using the PMV directly as the set point was verified by employing actual equipment in an air conditioning testing room and an office building. Prior to the execution of this control, the operation program of the PMV was installed in a DDC controller for the air conditioning control. And information from indoor sensors and so on was inputted to the controller, and the computed PMV was used as the feedback variable.

  14. Simulation Program i-SVOC User’s Guide

    EPA Science Inventory

    This document is the User’s Guide for computer program i-SVOC, which estimates the emissions, transport, and sorption of semivolatile organic compounds (SVOCs) in the indoor environment as a function of time when a series of initial conditions is given. This program implements a ...

  15. Development of wireless sensor network for monitoring indoor air pollutant

    NASA Astrophysics Data System (ADS)

    Saad, Shaharil Mad; Shakaff, Ali Yeon Md; Saad, Abdul Rahman Mohd; Yusof @ Kamarudin, Azman Muhamad

    2015-05-01

    The air that we breathe with everyday contains variety of contaminants and particles. Some of these contaminants and particles are hazardous to human health. Most of the people don't realize that the content of air they being exposed to whether it was a good or bad air quality. The air quality whether in indoor or outdoor environment can be influenced by physical factors like dust particles, gaseous pollutants (including carbon dioxide, carbon monoxide and volatile organic compounds) and biological like molds and bacteria growth which largely depend on temperature and humidity condition of a room. These kinds of pollutants can affect human health, physical reaction, comfort or work performance. In this study, a wireless sensor network (WSN) monitoring system for monitor air pollutant in indoor environment was developed. The system was divided into three parts: web-based interface program, sensing module and a base station. The measured data was displayed on the web which is can be accessed by the user. The result shows that the overall measured parameters were meet the acceptable limit, requirement and criteria of indoor air pollution inside the building. The research can be used to improve the indoor air quality level in order to create a comfortable working and healthy environment for the occupants inside the building.

  16. Fungal pollution of indoor environments and its management.

    PubMed

    Haleem Khan, A A; Mohan Karuppayil, S

    2012-10-01

    Indoor environments play important roles in human health. The health hazards posed by polluted indoor environments include allergy, infections and toxicity. Life style changes have resulted in a shift from open air environments to air tight, energy efficient, environments, in which people spend a substantial portion of their time. Most indoor air pollution comes from the hazardous non biological agents and biological agents. Fungi are ubiquitous in distribution and are a serious threat to public health in indoor environments. In this communication, we have reviewed the current status on biotic indoor air pollution, role of fungi as biological contaminants and their impact on human health.

  17. Fungal pollution of indoor environments and its management

    PubMed Central

    Haleem Khan, A.A.; Mohan Karuppayil, S.

    2012-01-01

    Indoor environments play important roles in human health. The health hazards posed by polluted indoor environments include allergy, infections and toxicity. Life style changes have resulted in a shift from open air environments to air tight, energy efficient, environments, in which people spend a substantial portion of their time. Most indoor air pollution comes from the hazardous non biological agents and biological agents. Fungi are ubiquitous in distribution and are a serious threat to public health in indoor environments. In this communication, we have reviewed the current status on biotic indoor air pollution, role of fungi as biological contaminants and their impact on human health. PMID:23961203

  18. Air-Sense: indoor environment monitoring evaluation system based on ZigBee network

    NASA Astrophysics Data System (ADS)

    Huang, Yang; Hu, Liang; Yang, Disheng; Liu, Hengchang

    2017-08-01

    In the modern life, people spend most of their time indoors. However, indoor environmental quality problems have always been affecting people’s social activities. In general, indoor environmental quality is also related to our indoor activities. Since most of the organic irritants and volatile gases are colorless, odorless and too tiny to be seen, because we have been unconsciously overlooked indoor environment quality. Consequently, our body suffer a great health problem. In this work, we propose Air-Sense system which utilizes the platform of ZigBee Network to collect and detect the real-time indoor environment quality. What’s more, Air-Sense system can also provide data analysis, and visualizing the results of the indoor environment to the user.

  19. Proactive approaches for mold-free interior environments.

    PubMed

    Warsco, Katherine; Lindsey, Patricia F

    2003-08-01

    Interior design education and practice can contribute to the prevention of mold growth in indoor environments. The authors provide an overview of current thinking within the interior design educational and professional communities regarding proactive approaches to achieving mold-free building interiors, including identification of current best practices for the prevention of mold problems in buildings. They also discuss the development of certification programs. A review of recent literature points to the need for interior designers to be educated to specify the use of ecologically sound materials that support the health of building occupants. The authors present trade-offs between best practices for designing mold-free indoor environments (including considerations of cost, maintenance, and operation) and occupant comfort, health, and well-being.

  20. Environmental Issues in Managing Asthma

    PubMed Central

    Diette, Gregory B; McCormack, Meredith C; Hansel, Nadia N; Breysse, Patrick N; Matsui, Elizabeth C

    2008-01-01

    Management of asthma requires attention to environmental exposures both indoors and outdoors. Americans spend most of their time indoors, where they have a greater ability to modify their environment. The indoor environment contains both pollutants (eg, particulate matter, nitrogen dioxide, secondhand smoke, and ozone) and allergens from furred pets, dust mites, cockroaches, rodents, and molds. Indoor particulate matter consists of particles generated from indoor sources such as cooking and cleaning activities, and particles that penetrate from the outdoors. Nitrogen dioxide sources include gas stoves, furnaces, and fireplaces. Indoor particulate matter and nitrogen dioxide are linked to asthma morbidity. The indoor ozone concentration is mainly influenced by the outdoor ozone concentration. The health effects of indoor ozone exposure have not been well studied. In contrast, there is substantial evidence of detrimental health effects from secondhand smoke. Guideline recommendations are not specific for optimizing indoor air quality. The 2007 National Asthma Education and Prevention Program asthma guidelines recommend eliminating indoor smoking and improving the ventilation. Though the guidelines state that there is insufficient evidence to recommend air cleaners, air cleaners and reducing activities that generate indoor pollutants may be sound practical approaches for improving the health of individuals with asthma. The guidelines are more specific about allergen avoidance; they recommend identifying allergens to which the individual is immunoglobin E sensitized and employing a multifaceted, comprehensive strategy to reduce exposure. Outdoor air pollutants that impact asthma include particulate matter, ozone, nitrogen dioxide, and sulfur dioxide, and guidelines recommend that individuals with asthma avoid exertion outdoors when these pollutants are elevated. Outdoor allergens include tree, grass, and weed pollens, which vary in concentration by season. Recommendations to reduce exposure include staying indoors, keeping windows and doors closed, using air conditioning and perhaps high-efficiency particulate arrestor (HEPA) air filters, and thorough daily washing to remove allergens from one’s person. PMID:18426614

  1. A View Indoors, Indoor Environment Division's e-Article Series

    EPA Pesticide Factsheets

    The Indoor Environments Division has created partnership with public and private sector entities to help encourage the public to take action to minimize their risk and mitigate indoor air quality problems.

  2. School policies and practices that improve indoor air quality.

    PubMed

    Everett Jones, Sherry; Smith, Alisa M; Wheeler, Lani S; McManus, Tim

    2010-06-01

    To determine whether schools with a formal indoor air quality management program were more likely than schools without a formal program to have policies and practices that promote superior indoor air quality. This study analyzed school-level data from the 2006 School Health Policies and Programs Study, a national study of school health programs and policies at the state, district, and school levels. Using chi-square analyses, the rates of policies and practices that promote indoor air quality were compared between schools with and schools without a formal indoor air quality program. The findings of this study show that 51.4% of schools had a formal indoor air quality management program, and that those schools were significantly more likely than were schools without a program to have policies and use strategies to promote superior indoor air quality. These findings suggest that schools with a formal indoor air quality program are more likely support policies and engage in practices that promote superior indoor air quality.

  3. In search of a common European approach to a healthy indoor environment.

    PubMed

    Adan, Olaf C G; Ng-A-Tham, Julie; Hanke, Wojtek; Sigsgaard, Torben; van den Hazel, Peter; Wu, Felicia

    2007-06-01

    Increasingly, policymakers in Europe and around the world are realizing the importance of healthy indoor environments for public health. Certain member states of the European Union (EU) have already achieved successes in improving indoor environmental quality, such as controlling certain contaminants (e.g., environmental tobacco smoke) or developing nationwide policies that address indoor air generally. However, a common European approach to achieving healthy indoor environments is desirable for several reasons including providing a broader recognition of the problem of unhealthy indoor air, setting a policy example for all 27 EU member states, and achieving greater public health equity across the different European nations. In this article we address the question "Why is it so difficult in the EU to develop a coherent approach on indoor environment?" We identify and describe four main barriers: a) the subsidiarity principle in EU policymaking, introducing decentralization of decision making to the member states; b) fragmentation of the topic of the indoor environment; c) the differences in climate and governance among different member states that make a common policy difficult; and d) economic issues. We discuss potential lessons and recommendations from EU and U.S. successes in achieving healthier indoor environments through various policy mechanisms.

  4. Indoor Environment in Residential Prefabricated Buildings

    NASA Astrophysics Data System (ADS)

    Kraus, Michal; Juhásová Šenitková, Ingrid

    2017-10-01

    The contribution presents results of the experimental measurement of indoor air quality in residential prefabricated buildings. People spend about 90% of their life in the indoor environment of buildings. Hygrothermal parameters and indoor air quality are the essential component that define the quality of the indoor environment. The results of case study characterize the quality of the indoor environment of the ordinary occupants in housing unit of residential prefabricated building. A current problem of revitalized prefabricated buildings is inadequate air exchange and related thereto to poor indoor air quality. The experimental measurements were carried out just before and at the beginning of the heating season (from 1st October to 30th November 2016). Heating season was launched in the middle of experimental measurement. The wireless indoor sensor Elgato Eve Room was used for measurements. The obtained values of indoor air temperature [°C], relative humidity [%] and indoor air quality [ppm] are describe and analysis in this study. The results of the study indicate that the values of temperature and indoor air quality meet optimal levels during the experiment with nuances. The mean air temperature in the indoor environment is 22.43 °C. The temperature of the indoor environment is held at the optimum level (18-24 °C) for 94.50% time of the experimental measurements. In addition, the indoor air quality in the context of the content of harmful volatile organic compounds (VOCs) has been excellent for almost 91% time of the total experiment. However, the values of relative humidity were less than the optimum value nearly 40% of the total observed time. The mean 10-minutes values of relative humidity during the heating season is about 10% lower than the mean 10-minutes relative humidity before the heating season.

  5. Inter-comparison of air pollutant concentrations in different indoor environments in Hong Kong

    NASA Astrophysics Data System (ADS)

    Lee, Shun-Cheng; Guo, Hai; Li, Wai-Ming; Chan, Lo-Yin

    Indoor air quality in selected indoor environments in Hong Kong such as homes, offices, schools, shopping malls and restaurants were investigated. Average CO 2 levels and total bacteria counts in air-conditioned classrooms, shopping malls and restaurants were comparatively higher than those measured in occupied offices and homes. Elevated CO 2 levels exceeding 1000 ppm and total bacteria counts resulted from high occupancy combined with inadequate ventilation. Average PM 10 levels were usually higher indoors than outdoors in homes, shopping malls and restaurants. The highest indoor PM 10 levels were observed at investigated restaurants due to the presence of cigarette smoking and extensive use of gas stoves for cooking. The restaurants and shopping malls investigated had higher formaldehyde levels than other indoor environments when building material, smoking and internal renovation work were present. Volatile organic compounds (VOCs) in both indoor and outdoor environments mainly resulted from vehicle exhaust emissions. It was observed that interior decoration work and the use of industrial solvents in an indoor environment could significantly increase the indoor levels of VOCs.

  6. Vapor Transport to Indoor Environments

    EPA Science Inventory

    The indoor environment is an important microenvironment for human exposure to chemicals, both because people spend most of their time indoors and because chemicals are often at higher concentrations indoors versus outdoors. This chapter reviews the major components in estimating ...

  7. Evolution of the indoor biome.

    PubMed

    Martin, Laura J; Adams, Rachel I; Bateman, Ashley; Bik, Holly M; Hawks, John; Hird, Sarah M; Hughes, David; Kembel, Steven W; Kinney, Kerry; Kolokotronis, Sergios-Orestis; Levy, Gabriel; McClain, Craig; Meadow, James F; Medina, Raul F; Mhuireach, Gwynne; Moreau, Corrie S; Munshi-South, Jason; Nichols, Lauren M; Palmer, Clare; Popova, Laura; Schal, Coby; Täubel, Martin; Trautwein, Michelle; Ugalde, Juan A; Dunn, Robert R

    2015-04-01

    Few biologists have studied the evolutionary processes at work in indoor environments. Yet indoor environments comprise approximately 0.5% of ice-free land area--an area as large as the subtropical coniferous forest biome. Here we review the emerging subfield of 'indoor biome' studies. After defining the indoor biome and tracing its deep history, we discuss some of its evolutionary dimensions. We restrict our examples to the species found in human houses--a subset of the environments constituting the indoor biome--and offer preliminary hypotheses to advance the study of indoor evolution. Studies of the indoor biome are situated at the intersection of evolutionary ecology, anthropology, architecture, and human ecology and are well suited for citizen science projects, public outreach, and large-scale international collaborations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. EVALUATION OF AIR PURIFICATION DEVICES FOR CONTROL OF INDOOR PM

    EPA Science Inventory

    Because people spend most of their time indoors (89%), the indoor environment is a primary determinant of particle exposure. The indoor environment is especially an important determinant for the very young, the very old, and those with underlying cardiopulmonary disease because...

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dickson, R.B.

    Indoor air pollution (IAP) is ranked by the Environmental Protection Agency (EPA) among the top five environmental risks to human health. The World Health Organization estimates that nearly one in every six commercial buildings in the United States suffers from sick-building syndrome and that occupants of another one in twelve suffer from building-related illnesses. Indoor air quality (IAQ) problems cost American business $10 billion per year through lowered productivity, absenteeism, and medical costs. Yet despite the importance and high cost of IAQ problems, indoor air is not yet specifically addressed in any federal regulatory program. The reason probably is becausemore » indoor air is a quanitatively different environment in which traditional modes of regulation, based on pollutant-by pollutant risk assessments, are of limited utility. This paper covers the following topics: four factors influencing IAQ regulation; EPA regulation of indoor air; the role of the consumer product safety commission; OSHA and IAQ issues; state regulation and economic concerns; the pressure for legislation.« less

  10. Rethinking Indoor Localization Solutions Towards the Future of Mobile Location-Based Services

    NASA Astrophysics Data System (ADS)

    Guney, C.

    2017-11-01

    Satellite navigation systems with GNSS-enabled devices, such as smartphones, car navigation systems, have changed the way users travel in outdoor environment. GNSS is generally not well suited for indoor location and navigation because of two reasons: First, GNSS does not provide a high level of accuracy although indoor applications need higher accuracies. Secondly, poor coverage of satellite signals for indoor environments decreases its accuracy. So rather than using GNSS satellites within closed environments, existing indoor navigation solutions rely heavily on installed sensor networks. There is a high demand for accurate positioning in wireless networks in GNSS-denied environments. However, current wireless indoor positioning systems cannot satisfy the challenging needs of indoor location-aware applications. Nevertheless, access to a user's location indoors is increasingly important in the development of context-aware applications that increases business efficiency. In this study, how can the current wireless location sensing systems be tailored and integrated for specific applications, like smart cities/grids/buildings/cars and IoT applications, in GNSS-deprived areas.

  11. A review of polychlorinated biphenyls (PCBs) pollution in indoor air environment.

    PubMed

    Dai, Qizhou; Min, Xia; Weng, Mili

    2016-10-01

    Polychlorinated biphenyls (PCBs) were widely used in industrial production due to the unique physical and chemical properties. As a kind of persistent organic pollutants, the PCBs would lead to environment pollution and cause serious problems for human health. Thus, they have been banned since the 1980s due to the environment pollution in the past years. Indoor air is the most direct and important environment medium to human beings; thus, the PCBs pollution research in indoor air is important for the protection of human health. This paper introduces the industrial application and potential harm of PCBs, summarizes the sampling, extracting, and analytical methods of environment monitoring, and compares the indoor air levels of urban areas with those of industrial areas in different countries according to various reports. This paper can provide a basic summary for PCBs pollution control in the indoor air environment. The review of PCBs pollution in indoor air in China is still limited. In this paper, we introduce the industrial application and potential harm of PCBs, summarize the sampling, extracting, and analytical methods of environment monitoring, and compare the indoor air levels of urban areas with industrial areas in different countries according to various reports.

  12. An experimental study on Sokkuram Cave Temple dome's indoor environment using a miniature model in winter season

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kong, S.H.; Chung, K.S.; Park, J.S.

    1999-07-01

    Currently, there are many researches on the analysis of indoor environment in Sokkuram Cave Temple. However, there is not enough researches about an experimental study on the dome's indoor environment in Sokkuram Cave Temple using a miniature model. The purpose of this investigation is to measure and analyze characteristics of indoor environment such as relative humidity, dry bulb temperature and air velocity in the miniature model of Sokkuram Cave dome during winter season.

  13. Investigating the Feasibility of Conducting Human Tracking and Following in an Indoor Environment Using a Microsoft Kinect and the Robot Operating System

    DTIC Science & Technology

    2017-06-01

    implement human following on a mobile robot in an indoor environment . B. FUTURE WORK Future work that could be conducted in the realm of this thesis...FEASIBILITY OF CONDUCTING HUMAN TRACKING AND FOLLOWING IN AN INDOOR ENVIRONMENT USING A MICROSOFT KINECT AND THE ROBOT OPERATING SYSTEM by...FEASIBILITY OF CONDUCTING HUMAN TRACKING AND FOLLOWING IN AN INDOOR ENVIRONMENT USING A MICROSOFT KINECT AND THE ROBOT OPERATING SYSTEM 5. FUNDING NUMBERS

  14. Study on indoor thermal environment in winter for rural residences in Yulin region

    NASA Astrophysics Data System (ADS)

    Yanjun, Li; Weixiao, Han

    2018-02-01

    Yulin region is located in the northern part of Shaanxi Province, China. The winter here is very cold and it has a long duration. In this paper, a rural residence which was located in Yulin region was taken as a study object. Indoor thermal environment of the rural residence were tested, including indoor air temperature and air relative humidity. Then, test data were analyzed. It was summarized that indoor thermal environment of test room can not fully meet human thermal comfort needs, and some tactics of regulation building thermal environment were proposed. This research contributes to improvement of indoor thermal environment for local rural residences and it provides reference for rural residences in other cold regions.

  15. 40 CFR 35.708 - Award limitations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....708 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Environmental Program Grants for Tribes Indoor Radon Grants (section 306...)(iv)) and demonstration of radon mitigation, methods, and technologies (see § 35.820(b)(1)(ix)) shall...

  16. The effect of the indoor environment on the fate of organic chemicals in the urban landscape.

    PubMed

    Cousins, Anna Palm

    2012-11-01

    To assess the effect of the indoor environment on the urban fate of organic chemicals, an 8-compartment indoor-inclusive steady state multimedia chemical fate model was developed. The model includes typical urban compartments (air, soil, water, sediment, and urban film) and a novel module representing a generic indoor environment. The model was parameterized to the municipality of Stockholm, Sweden and applied to four organic chemicals with different physical-chemical characteristics and use patterns: formaldehyde, 2,4,6-tribromophenol, di-ethylhexylphthalate and decabromodiphenyl ether. The results show that emissions to indoor air may increase the steady state mass and residence time in the urban environment by a factor of 1.1 to 22 for the four chemicals, compared to if emissions are assigned to outdoor air. This is due to the nested nature of the indoor environment, which creates a physical barrier that prevents chemicals from leaving the urban system with outflowing air. For DEHP and BDE 209, the additional partitioning to indoor surfaces results in a greater importance of the indoor removal pathways from surfaces. The outdoor environmental concentrations of these chemicals are predicted to be lower if emitted to indoor air than if emitted to outdoor air because of the additional indoor removal pathways of dust and indoor film, leading to loss of chemical from the system. For formaldehyde and 2,4,6-TBP outdoor environmental concentrations are not affected by whether the release occurs indoors or outdoors because of the limited partitioning to indoor surfaces. A sensitivity analysis revealed that there appears to be a relationship between logK(OA) and the impact of the ventilation rate on the urban fate of organic chemicals. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Calculating Least Risk Paths in 3d Indoor Space

    NASA Astrophysics Data System (ADS)

    Vanclooster, A.; De Maeyer, Ph.; Fack, V.; Van de Weghe, N.

    2013-08-01

    Over the last couple of years, research on indoor environments has gained a fresh impetus; more specifically applications that support navigation and wayfinding have become one of the booming industries. Indoor navigation research currently covers the technological aspect of indoor positioning and the modelling of indoor space. The algorithmic development to support navigation has so far been left mostly untouched, as most applications mainly rely on adapting Dijkstra's shortest path algorithm to an indoor network. However, alternative algorithms for outdoor navigation have been proposed adding a more cognitive notion to the calculated paths and as such adhering to the natural wayfinding behaviour (e.g. simplest paths, least risk paths). These algorithms are currently restricted to outdoor applications. The need for indoor cognitive algorithms is highlighted by a more challenged navigation and orientation due to the specific indoor structure (e.g. fragmentation, less visibility, confined areas…). As such, the clarity and easiness of route instructions is of paramount importance when distributing indoor routes. A shortest or fastest path indoors not necessarily aligns with the cognitive mapping of the building. Therefore, the aim of this research is to extend those richer cognitive algorithms to three-dimensional indoor environments. More specifically for this paper, we will focus on the application of the least risk path algorithm of Grum (2005) to an indoor space. The algorithm as proposed by Grum (2005) is duplicated and tested in a complex multi-storey building. The results of several least risk path calculations are compared to the shortest paths in indoor environments in terms of total length, improvement in route description complexity and number of turns. Several scenarios are tested in this comparison: paths covering a single floor, paths crossing several building wings and/or floors. Adjustments to the algorithm are proposed to be more aligned to the specific structure of indoor environments (e.g. no turn restrictions, restricted usage of rooms, vertical movement) and common wayfinding strategies indoors. In a later stage, other cognitive algorithms will be implemented and tested in both an indoor and combined indoor-outdoor setting, in an effort to improve the overall user experience during navigation in indoor environments.

  18. Emerging developments in the standardized chemical characterization of indoor air quality.

    PubMed

    Nehr, Sascha; Hösen, Elisabeth; Tanabe, Shin-Ichi

    2017-01-01

    Despite the fact that the special characteristics of indoor air pollution make closed environments quite different from outdoor environments, the conceptual ideas for assessing air quality indoors and outdoors are similar. Therefore, the elaboration of International Standards for air quality characterization in view of controlling indoor air quality should resort to this common basis. In this short review we describe the possibilities of standardization of tools dedicated to indoor air quality characterization with a focus on the tools permitting to study the indoor air chemistry. The link between indoor exposure and health as well as the critical processes driving the indoor air quality are introduced. Available International Standards for the assessment of indoor air quality are depicted. The standards comprise requirements for the sampling on site, the analytical procedures, and the determination of material emissions. To date, these standardized procedures assure that indoor air, settled dust and material samples are analyzed in a comparable manner. However, existing International Standards exclusively specify conventional, event-driven target-screening using discontinuous measurement methods for long-lived pollutants. Therefore, this review draws a parallel between physico-chemical processes in indoor and outdoor environments. The achievements in atmospheric sciences also improve our understanding of indoor environments. The community of atmospheric scientists can be both ideal and supporter for researchers in the area of indoor air quality characterization. This short review concludes with propositions for future standardization activities for the chemical characterization of indoor air quality. Future standardization efforts should focus on: (i) the elaboration of standardized measurement methods and measurement strategies for online monitoring of long-lived and short-lived pollutants, (ii) the assessment of the potential and the limitations of non-target screening, (iii) the paradigm shift from event-driven investigations to systematic approaches to characterize indoor environments, and (iv) the development of tools for policy implementation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Teachers and Healthy Indoor School Environments

    EPA Pesticide Factsheets

    Teachers can be powerful advocates for creating healthy indoor environments, including improving school indoor air quality (IAQ). As they are on the front lines, teachers can perceive when IAQ changes affect students and themselves.

  20. 40 CFR Appendix A to Subpart F of... - References

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Indoor Air Sampling: Design and Calibration., JAPCA, 37: 1303-1307 (1987). (2) Vanderpool, R.W. and K.L... Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Performance Characteristics...

  1. 40 CFR Appendix A to Subpart F of... - References

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Indoor Air Sampling: Design and Calibration., JAPCA, 37: 1303-1307 (1987). (2) Vanderpool, R.W. and K.L... Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Performance Characteristics...

  2. The use of modern technologies in carbon dioxide monitoring

    NASA Astrophysics Data System (ADS)

    Komínek, Petr; Weyr, Jan; Hirš, Jiří

    2017-12-01

    Indoor environment has huge influence on person's health and overall comfort. It is of great importance that we realize how essential indoor air quality is, considering we spend on average as much as 90% of our time indoors. There are many factors that affect indoor air quality: specifically, inside air temperature, relative humidity, and odors to name the most important factors. One of the key factors indicating indoor air quality is carbon dioxide (CO2) level. The CO2 levels, measured in prefab apartment buildings, indicates substantial indoor air quality issues. Therefore, a proper education of the occupants is of utmost importance. Also, great care should be directed towards technical and technological solutions that would ensure meeting the normative indoor environment criteria, especially indoor air CO2 levels. Thanks to the implementation of new emerging autonomous technologies, such as Internet of Things (IoT), monitoring in real-time is enhanced. An area where IoT plays a major role is in the monitoring of indoor environment. IoT technology (e.g. smart meters and sensors) provide awareness of information about the quality of indoor environment. There is a huge potential for influencing behaviour of the users. Through the web application, it is possible to educate people and ensure fresh air supply.

  3. Performance Evaluation of Indoor Environment towards Sustainability for Higher Educational Buildings

    ERIC Educational Resources Information Center

    Khalil, Natasha; Husin, Husrul Nizam; Wahab, Lilawati Ab; Kamal, Kamarul Syahril; Mahat, Noorsaidi

    2011-01-01

    The indoor environmental factors considered in higher educational building must be determined in order to meet the user's requirement. Disruption of indoor environment may constitute to reduce occupants' efficiencies and their learning process and activities. But the question is, how to ensure that the provision of indoor environmental aspects…

  4. Influenza transmission during extreme indoor conditions in a low-resource tropical setting

    NASA Astrophysics Data System (ADS)

    Tamerius, James; Ojeda, Sergio; Uejio, Christopher K.; Shaman, Jeffrey; Lopez, Brenda; Sanchez, Nery; Gordon, Aubree

    2017-04-01

    Influenza transmission occurs throughout the planet across wide-ranging environmental conditions. However, our understanding of the environmental factors mediating transmission is evaluated using outdoor environmental measurements, which may not be representative of the indoor conditions where influenza is transmitted. In this study, we examined the relationship between indoor environment and influenza transmission in a low-resource tropical population. We used a case-based ascertainment design to enroll 34 households with a suspected influenza case and then monitored households for influenza, while recording indoor temperature and humidity data in each household. We show that the indoor environment is not commensurate with outdoor conditions and that the relationship between indoor and outdoor conditions varies significantly across homes. We also show evidence of influenza transmission in extreme indoor environments. Specifically, our data suggests that indoor environments averaged 29 °C, 18 g/kg specific humidity, and 68 % relative humidity across 15 transmission events observed. These indoor settings also exhibited significant temporal variability with temperatures as high as 39 °C and specific and relative humidity increasing to 22 g/kg and 85 %, respectively, during some transmission events. However, we were unable to detect differences in the transmission efficiency by indoor temperature or humidity conditions. Overall, these results indicate that laboratory studies investigating influenza transmission and virus survival should increase the range of environmental conditions that they assess and that observational studies investigating the relationship between environment and influenza activity should use caution using outdoor environmental measurements since they can be imprecise estimates of the conditions that mediate transmission indoors.

  5. Influenza transmission during extreme indoor conditions in a low-resource tropical setting.

    PubMed

    Tamerius, James; Ojeda, Sergio; Uejio, Christopher K; Shaman, Jeffrey; Lopez, Brenda; Sanchez, Nery; Gordon, Aubree

    2017-04-01

    Influenza transmission occurs throughout the planet across wide-ranging environmental conditions. However, our understanding of the environmental factors mediating transmission is evaluated using outdoor environmental measurements, which may not be representative of the indoor conditions where influenza is transmitted. In this study, we examined the relationship between indoor environment and influenza transmission in a low-resource tropical population. We used a case-based ascertainment design to enroll 34 households with a suspected influenza case and then monitored households for influenza, while recording indoor temperature and humidity data in each household. We show that the indoor environment is not commensurate with outdoor conditions and that the relationship between indoor and outdoor conditions varies significantly across homes. We also show evidence of influenza transmission in extreme indoor environments. Specifically, our data suggests that indoor environments averaged 29 °C, 18 g/kg specific humidity, and 68 % relative humidity across 15 transmission events observed. These indoor settings also exhibited significant temporal variability with temperatures as high as 39 °C and specific and relative humidity increasing to 22 g/kg and 85 %, respectively, during some transmission events. However, we were unable to detect differences in the transmission efficiency by indoor temperature or humidity conditions. Overall, these results indicate that laboratory studies investigating influenza transmission and virus survival should increase the range of environmental conditions that they assess and that observational studies investigating the relationship between environment and influenza activity should use caution using outdoor environmental measurements since they can be imprecise estimates of the conditions that mediate transmission indoors.

  6. Potential Nationwide Improvements in Productivity and Health from Better Indoor Environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisk, W.J.; Rosenfeld, A.H.

    1998-05-01

    Theoretical considerations and empirical data suggest that existing technologies and procedures can improve indoor environments in a manner that significantly increases productivity and health. Existing literature contains moderate to strong evidence that characteristics of buildings and indoor environments significantly influence rates of respiratory disease, allergy and asthma symptoms, sick building symptoms, and worker performance. While there is considerable uncertainty in our estimates of the magnitudes of productivity gains that may be obtained by providing better indoor environments, the projected gains are very large. For the U.S., we estimate potential annual savings and productivity gains of $6 to $19 billion frommore » reduced respiratory disease, $1 to $4 billion from reduced allergies and asthma, $10 to $20 billion from reduced sick building syndrome symptoms, and $12 to $125 billion from direct improvements in worker performance that are unrelated to health. In two example calculations, the potential financial benefits of improving indoor environments exceed costs by a factor of 8 and 14. Productivity gains that are quantified and demonstrated could serve as a strong stimulus for energy efficiency measures that simultaneously improve the indoor environment.« less

  7. Potential nationwide improvements in productivity and health from better indoor environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisk, W.J.; Rosenfeld, A.H.

    1998-07-01

    Theoretical considerations and empirical data suggest that existing technologies and procedures can improve indoor environments in a manner that significantly increases productivity and health. Existing literature contains moderate to strong evidence that characteristics of buildings and indoor environments significantly influence rates of respiratory disease, allergy and asthma symptoms, sick building symptoms, and worker performance. While there is considerable uncertainty in their estimates of the magnitudes of productivity gains that may be obtained by providing better indoor environments, the projected gains are very large. For the US, the authors estimate potential annual savings and productivity gains of $6 to $19 billionmore » from reduced respiratory disease, $1 to $4 billion from reduced allergies and asthma, $10 to $20 billion from reduced sick building syndrome symptoms, and $12 to $125 billion from direct improvements in worker performance that are unrelated to health. In two example calculations, the potential financial benefits of improving indoor environments exceed costs by a factor of 8 and 14. Productivity gains that are quantified and demonstrated could serve as a strong stimulus for energy efficiency measures that simultaneously improve the indoor environment.« less

  8. Healthy Indoor Environment Protocols for Home Energy Upgrades

    EPA Pesticide Factsheets

    This page contains the EPA-developed Healthy Indoor Environment Protocols for Home Energy Upgrades, a PDF guide that provides a set of best practices for improving indoor air quality in conjunction with energy upgrade work in homes.

  9. 40 CFR 98.449 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... into the atmosphere, indoor air, oceans, or surface water. Underground Injection Control permit means a... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY... below, all terms used in this subpart have the same meaning given in the Clean Air Act and subpart A of...

  10. 40 CFR 35.298 - Award limitations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....298 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Environmental Program Grants State Indoor Radon Grants (section 306) § 35.298... measurement equipment or devices (see § 35.290(b)(1)(iv)) and demonstration of radon mitigation, methods, and...

  11. Indoor navigation by image recognition

    NASA Astrophysics Data System (ADS)

    Choi, Io Teng; Leong, Chi Chong; Hong, Ka Wo; Pun, Chi-Man

    2017-07-01

    With the progress of smartphones hardware, it is simple on smartphone using image recognition technique such as face detection. In addition, indoor navigation system development is much slower than outdoor navigation system. Hence, this research proves a usage of image recognition technique for navigation in indoor environment. In this paper, we introduced an indoor navigation application that uses the indoor environment features to locate user's location and a route calculating algorithm to generate an appropriate path for user. The application is implemented on Android smartphone rather than iPhone. Yet, the application design can also be applied on iOS because the design is implemented without using special features only for Android. We found that digital navigation system provides better and clearer location information than paper map. Also, the indoor environment is ideal for Image recognition processing. Hence, the results motivate us to design an indoor navigation system using image recognition.

  12. Microbial Resistant Test Method Development

    EPA Science Inventory

    Because humans spend most of their time in the indoor environment, environmental analysis of the quality of indoor air has become an important research topic. A major component of the aerosol in the indoor environment consists of biological particles, called bioaerosols, and fur...

  13. MANAGING EXPOSURE TO INDOOR AIR POLLUTANTS IN RESIDENTIAL AND OFFICE ENVIRONMENTS

    EPA Science Inventory

    The paper discusses the factors to be considered in managing indoor air pollutants in residential and office environments to reduce occupant exposures. Techniques for managing indoor air pollution sources include: source elimination, substitution, modification, and pretreatment a...

  14. THE ALLERGENIC POTENTIAL OF INDOOR AIR FUNGAL CONTAMINANTS

    EPA Science Inventory

    ABSTRACT

    The indoor environment has increased in importance to children's health with children now spending more than 90% of their time indoors. Molds are an important component of this environment and have been associated with exacerbation of asthma. Their contribution t...

  15. PM 2.5, soot and NO 2 indoor-outdoor relationships at homes, pre-schools and schools in Stockholm, Sweden

    NASA Astrophysics Data System (ADS)

    Wichmann, J.; Lind, T.; Nilsson, M. A.-M.; Bellander, T.

    2010-11-01

    In developed nations people spend about 90% of their time indoors. The relationship between indoor and outdoor air pollution levels is important for the understanding of the health effects of outdoor air pollution. Although other studies describe both the outdoor and indoor atmospheric environment, few excluded a priori major indoor sources, measured the air exchange rate, included more than one micro-environment and included the presence of human activity. PM 2.5, soot, NO 2 and the air exchange rate were measured during winter and summer indoors and outdoors at 18 homes (mostly apartments) of 18 children (6-11-years-old) and also at the six schools and 10 pre-schools that the children attended. The three types of indoor environments were free of environmental tobacco smoke and gas appliances, as the aim was to asses to what extent PM 2.5, soot and NO 2 infiltrate from outdoors to indoors. The median indoor and outdoor PM 2.5 levels were 8.4 μg m -3 and 9.3 μg m -3, respectively. The median indoor levels for soot and NO 2 were 0.66 m -1 × 10 -5 and 10.0 μg m -3, respectively. The respective outdoor levels were 0.96 m -1 × 10 -5 and 12.4 μg m -3. The median indoor/outdoor (I/O) ratios were 0.93, 0.76 and 0.92 for PM 2.5, soot and NO 2, respectively. Their infiltration factors were influenced by the micro-environment, ventilation type and air exchange rate, with aggregated values of 0.25, 0.55 and 0.64, respectively. Indoor and outdoor NO 2 levels were strongly associated ( R2 = 0.71), followed by soot ( R2 = 0.50) and PM 2.5 ( R2 = 0.16). In Stockholm, the three major indoor environments occupied by children offer little protection against combustion-related particles and gases in the outdoor air. Outdoor PM 2.5 seems to infiltrate less, but indoor sources compensate.

  16. INDOOR FUNGAL CONTAMINANTS: ASSESSING THE ALLERGIC POTENTIAL

    EPA Science Inventory

    The indoor environment has increased in importance to children's health with children now spending more than 90% of their time indoors. Molds are an important component of this environment and have been associated with exacerbation of asthma as well as a number of other health e...

  17. ENVIRONMENTAL TECHNOLOGY VERIFICATION AND INDOOR AIR

    EPA Science Inventory

    The paper discusses environmental technology verification and indoor air. RTI has responsibility for a pilot program for indoor air products as part of the U.S. EPA's Environmental Technology Verification (ETV) program. The program objective is to further the development of sel...

  18. Indoor-Outdoor Detection Using a Smart Phone Sensor.

    PubMed

    Wang, Weiping; Chang, Qiang; Li, Qun; Shi, Zesen; Chen, Wei

    2016-09-22

    In the era of mobile internet, Location Based Services (LBS) have developed dramatically. Seamless Indoor and Outdoor Navigation and Localization (SNAL) has attracted a lot of attention. No single positioning technology was capable of meeting the various positioning requirements in different environments. Selecting different positioning techniques for different environments is an alternative method. Detecting the users' current environment is crucial for this technique. In this paper, we proposed to detect the indoor/outdoor environment automatically without high energy consumption. The basic idea was simple: we applied a machine learning algorithm to classify the neighboring Global System for Mobile (GSM) communication cellular base station's signal strength in different environments, and identified the users' current context by signal pattern recognition. We tested the algorithm in four different environments. The results showed that the proposed algorithm was capable of identifying open outdoors, semi-outdoors, light indoors and deep indoors environments with 100% accuracy using the signal strength of four nearby GSM stations. The required hardware and signal are widely available in our daily lives, implying its high compatibility and availability.

  19. Human physiological responses to wooden indoor environment.

    PubMed

    Zhang, Xi; Lian, Zhiwei; Wu, Yong

    2017-05-15

    Previous studies are mainly focused on non-wooden environments, whereas few are concerned with wooden ones. How wooden indoor environments impact the physiology of the occupants is still unclear. The purpose of this study was to explore the distinct physiological responses to wooden and non-wooden indoor environments, assessed by physiological parameters tests including blood pressure, electrocardiogram measurements, electro-dermal activity, oxyhemoglobin saturation, skin temperature, and near distance vision. Twenty healthy adults participated in this experiment, and their physiological responses were evaluated in a 90minute investigation. The results illustrated that; less tension and fatigue were generated in the wooden rooms than in the non-wooden rooms when the participants did their work. In addition, the study also found that the wooden environments benefit the autonomic nervous system, respiratory system, and visual system. Moreover, wooden rooms play a valuable role in physiological regulation and ease function especially after a consecutive period of work. These results provide an experimental basis to support that wooden environment is beneficial to indoor occupants than the non-wooden indoor environment. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Assessing indoor air quality of school environments: transplanted lichen Pseudovernia furfuracea as a new tool for biomonitoring and bioaccumulation.

    PubMed

    Protano, Carmela; Owczarek, Malgorzata; Antonucci, Arianna; Guidotti, Maurizio; Vitali, Matteo

    2017-07-01

    The aim of this research is to evaluate the ability of transplanted lichen Pseudovernia (P). furfuracea to biomonitor and bioaccumulate in urban indoor environments. The elements As, Cd, Cr, Cu, Hg, Ni and Pb and 12 selected polycyclic aromatic hydrocarbons (PAHs) were used to assess P. furfuracea as a biomonitoring tool for the indoor air quality of school environments. To achieve this purpose, lichen samples were exposed for 2 months in the outdoor and indoor environments of five school settings located in urban and rural areas. The results demonstrated that transplanted lichen P. furfuracea is a suitable biomonitoring tool for metals and PAHs in indoor settings and can discriminate between different levels of air pollution related to urbanisation and indoor conditions, such as those characterised by school environments. A transplanted lichen biomonitoring strategy is cost-effective, "green", educational for attending children and less "invasive" than traditional air sampling methods. The feasibility of indoor monitoring by P. furfuracea is a relevant finding and could be a key tool to improve air quality monitoring programmes in school scenarios and thus focus on health prevention interventions for children, who are one of the most susceptible groups in the population.

  1. A review of the impacts of tobacco heating system on indoor air quality versus conventional pollution sources.

    PubMed

    Kaunelienė, Violeta; Meišutovič-Akhtarieva, Marija; Martuzevičius, Dainius

    2018-05-08

    With the introduction of novel and potentially less polluting nicotine containing products to the market, the impacts of their usage to indoor air quality as opposed to conventional pollution sources must be reviewed and considered. This review study aimed to comparatively analyse changes in indoor air quality as the consequence of tobacco heating system (THS) generated pollution against general indoor air quality in various micro-environments, especially with combustion-based pollution sources present. Indoor concentrations of formaldehyde, acetaldehyde, benzene, toluene, nicotine and PM 2.5 were reviewed and compared; concentrations of other harmful and potentially harmful substances (HPHCs) were discussed. Generally, the usage of THS has been associated with lower or comparable indoor air pollutant concentrations compared against other conventional indoor sources or environments, in most cases distinguishable above background, thus potentially being associated with health effects at prolonged exposures as any other artificial air pollution source. In the controlled environment the use of THS (as well as an electronic cigarette) resulted in the lowest concentrations of formaldehyde, benzene, toluene, PM 2.5, among majority researched pollution sources (conventional cigarettes, waterpipe, incense, mosquito coils). The exposure to significantly higher pollution levels of benzene, toluene, and formaldehyde occurred in public environments, especially transport micro-environments. Such low levels of conventionally-assessed indoor pollutants resulting from the use of new nicotine containing products raise challenges for epidemiological studies of second-hand exposure to THS aerosol in real-life environments. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Moving Environmental Justice Indoors: Understanding Structural Influences on Residential Exposure Patterns in Low-Income Communities.

    EPA Science Inventory

    The indoor environment has not been fully incorporated into the environmental justice dialogue. To inform strategies to reduce disparities, we developed a framework to identify the individual and place-based drivers of indoor environment quality. We reviewed empirical evidence...

  3. Airborne particles in indoor environment of homes, schools, offices and aged care facilities: The main routes of exposure.

    PubMed

    Morawska, L; Ayoko, G A; Bae, G N; Buonanno, G; Chao, C Y H; Clifford, S; Fu, S C; Hänninen, O; He, C; Isaxon, C; Mazaheri, M; Salthammer, T; Waring, M S; Wierzbicka, A

    2017-11-01

    It has been shown that the exposure to airborne particulate matter is one of the most significant environmental risks people face. Since indoor environment is where people spend the majority of time, in order to protect against this risk, the origin of the particles needs to be understood: do they come from indoor, outdoor sources or both? Further, this question needs to be answered separately for each of the PM mass/number size fractions, as they originate from different sources. Numerous studies have been conducted for specific indoor environments or under specific setting. Here our aim was to go beyond the specifics of individual studies, and to explore, based on pooled data from the literature, whether there are generalizable trends in routes of exposure at homes, schools and day cares, offices and aged care facilities. To do this, we quantified the overall 24h and occupancy weighted means of PM 10 , PM 2.5 and PN - particle number concentration. Based on this, we developed a summary of the indoor versus outdoor origin of indoor particles and compared the means to the WHO guidelines (for PM 10 and PM 2.5 ) and to the typical levels reported for urban environments (PN). We showed that the main origins of particle metrics differ from one type of indoor environment to another. For homes, outdoor air is the main origin of PM 10 and PM 2.5 but PN originate from indoor sources; for schools and day cares, outdoor air is the source of PN while PM 10 and PM 2.5 have indoor sources; and for offices, outdoor air is the source of all three particle size fractions. While each individual building is different, leading to differences in exposure and ideally necessitating its own assessment (which is very rarely done), our findings point to the existence of generalizable trends for the main types of indoor environments where people spend time, and therefore to the type of prevention measures which need to be considered in general for these environments. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Relative Panoramic Camera Position Estimation for Image-Based Virtual Reality Networks in Indoor Environments

    NASA Astrophysics Data System (ADS)

    Nakagawa, M.; Akano, K.; Kobayashi, T.; Sekiguchi, Y.

    2017-09-01

    Image-based virtual reality (VR) is a virtual space generated with panoramic images projected onto a primitive model. In imagebased VR, realistic VR scenes can be generated with lower rendering cost, and network data can be described as relationships among VR scenes. The camera network data are generated manually or by an automated procedure using camera position and rotation data. When panoramic images are acquired in indoor environments, network data should be generated without Global Navigation Satellite Systems (GNSS) positioning data. Thus, we focused on image-based VR generation using a panoramic camera in indoor environments. We propose a methodology to automate network data generation using panoramic images for an image-based VR space. We verified and evaluated our methodology through five experiments in indoor environments, including a corridor, elevator hall, room, and stairs. We confirmed that our methodology can automatically reconstruct network data using panoramic images for image-based VR in indoor environments without GNSS position data.

  5. Health and productivity gains from better indoor environments and their relationship with building energy efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisk, William J.

    2000-04-01

    Theoretical considerations and empirical data suggest that existing technologies and procedures can improve indoor environments in a manner that significantly increases productivity and health. Existing literature contains moderate to strong evidence that characteristics of buildings and indoor environments significantly influence rates of communicable respiratory illness, allergy and asthma symptoms, sick building symptoms, and worker performance. While there is considerable uncertainty in the estimates of the magnitudes of productivity gains that may be obtained by providing better indoor environments, the projected gains are very large. For the U.S., the estimated potential annual savings and productivity gains are $6 to $14 billionmore » from reduced respiratory disease, $2 to $4 billion from reduced allergies and asthma, $10 to $30 billion from reduced sick building syndrome symptoms, and $20 to $160 billion from direct improvements in worker performance that are unrelated to health. Productivity gains that are quantified and demonstrated could serve as a strong stimulus for energy efficiency measures that simultaneously improve the indoor environment.« less

  6. Indoor air quality in public utility environments-a review.

    PubMed

    Śmiełowska, Monika; Marć, Mariusz; Zabiegała, Bożena

    2017-04-01

    Indoor air quality has been the object of interest for scientists and specialists from the fields of science such as chemistry, medicine and ventilation system design. This results from a considerable number of potential factors, which may influence the quality of the broadly understood indoor air in a negative way. Poor quality of indoor air in various types of public utility buildings may significantly affect an increase in the incidence of various types of civilisation diseases. This paper presents information about a broad spectrum of chemical compounds that were identified and determined in the indoor environment of various types of public utility rooms such as churches, museums, libraries, temples and hospitals. An analysis of literature data allowed for identification of the most important transport paths of chemical compounds that significantly influence the quality of the indoor environment and thus the comfort of living and the health of persons staying in it.

  7. Applying Outdoor Environment to Develop Health, Comfort, and Energy Saving in the Office in Hot-Humid Climate

    PubMed Central

    Chen, Rong; Sung, Wen-Pei; Chang, Hung-Chang; Chi, Yi-Rou

    2013-01-01

    A human life demand set to emerge in the future is the achievement of sustainability by maintaining a comfortable indoor environment without excessive reliance on energy-consuming air conditioners. The major research processes in this study are: (1) measuring indoor air quality and thermal comfort to evaluate the comfort of an indoor environment; (2) implementing questionnaire survey analysis to explore people's environmental self-perceptions and conducting a meta-analysis of the measurement results for air quality and physical aspects; and (3) constructing an indoor monitoring and management system. The experimental and analysis results of this research reveal that most of the office occupants preferred a cooler environment with a lower temperature. Additionally, because the summers in Taiwan are humid and hot, the occupants of an indoor space tend to feel uncomfortable because of the high humidity and poor indoor air quality. Therefore, Variable Air Volume (VAV), two air intakes, and exhaust plant are installed to improve indoor environment. After improvement, a lower temperature (approximately 21.2–23.9°C) indirectly reduces humidity, thereby making the occupants comfortable. Increasing air velocity to 0.1 ~ 0.15 m/s, the carbon dioxide concentrations decrease below the requirement of the WHO. Ninety-five percent of the workers corresponded to the standard comfort zone after this improvement. PMID:24311976

  8. How to Create Healthy Indoor Environments in Schools

    ERIC Educational Resources Information Center

    Rhodes, Diane; Di Nella, Frank

    2012-01-01

    A green and healthy indoor environment should be a fundamental concern in the place where kids learn and grow. Good indoor air quality (IAQ) has been shown to have positive effects on student and staff productivity, performance, comfort and attendance. Conversely, poor IAQ in classrooms--caused by mold and moisture issues, problems with HVAC…

  9. New Courses: Unlock the Mysteries of Productivity, Air Quality, and the Indoor Environment in Schools.

    ERIC Educational Resources Information Center

    Raiford, Regina

    2001-01-01

    Discusses the relationship between indoor air quality and productivity and a three-year research project to measure productivity within an educational setting. Also discusses research showing the impact of good indoor air quality on increasing productivity. Ten ways to manage asthma in a school environment are highlighted. (GR)

  10. Assessment of indoor air problems at work with a questionnaire

    PubMed Central

    Reijula, K; Sundman-Digert, C

    2004-01-01

    Aims: To assess the extent of indoor air problems in office environments in Finland. Methods: Complaints and symptoms related to the indoor environment experienced by office workers were collected from 122 workplaces in 1996–99 by using the modified Indoor Air Questionnaire established by the Finnish Institute of Occupational Health. Altogether 11 154 employees took part in the survey. Results: The most common problems were dry air (35% of the respondents), stuffy air (34%), dust or dirt in the indoor environment (25%), and draught (22%). The most common work related symptoms were irritated, stuffy, or runny nose (20%), itching, burning, or irritation of the eyes (17%), and fatigue (16%). Women reported indoor air problems and work related symptoms more often than men. Allergic persons and smokers reported indoor air problems more often, and experienced work related symptoms more often than non-allergic persons and non-smokers. Conclusions: The complaints and work related symptoms associated with indoor air problems were common in office workers. The present questionnaire is a suitable tool for the occupational health personnel in investigating indoor air problems and the data of the survey can be used as a reference when the results of a survey at work are being analysed. PMID:14691270

  11. Outdoor infiltration and indoor contribution of UFP and BC, OC, secondary inorganic ions and metals in PM2.5 in schools

    NASA Astrophysics Data System (ADS)

    Rivas, I.; Viana, M.; Moreno, T.; Bouso, L.; Pandolfi, M.; Alvarez-Pedrerol, M.; Forns, J.; Alastuey, A.; Sunyer, J.; Querol, X.

    2015-04-01

    Infiltration of outdoor-sourced particles into indoor environments in 39 schools in Barcelona was assessed during school hours. Tracers of road traffic emissions (NO2, Equivalent Black Carbon (EBC), Ultrafine Particles (UFP), Sb), secondary inorganic aerosols (SO42-, NO3-, NH4+) and a number of PM2.5 trace elements showed median indoor/outdoor (I/O) ratios ≤ 1, indicating that outdoor sources importantly contributed to indoor concentrations. Conversely, OC and mineral components had I/O ratios>1. Different infiltration factors were found for traffic and secondary components (0.31-0.75 and 0.50-0.92, cold and warm season respectively), with maxima corresponding to EBC and Cd. Higher concentrations of indoor-generated particles were observed when closed windows hindered dispersion (cold season). Building age was not a major determinant of indoor levels. Neither were the window's material, except for NO2 (with an increase of 8 μg m-3 for wood framed windows) and the mineral components (also dependent on the presence of sand in a distance <20 m) that reach the indoor environment via soil adhering to footwear with their dispersion being more barred by Aluminium/PVC framed windows than the wooden ones. Enlarged indoor concentrations of some trace elements suggest the presence of indoor sources that should be further investigated in order to achieve a healthier school indoor environment.

  12. Transmission of Airborne Bacteria across Built Environments and Its Measurement Standards: A Review.

    PubMed

    Fujiyoshi, So; Tanaka, Daisuke; Maruyama, Fumito

    2017-01-01

    Human health is influenced by various factors including microorganisms present in built environments where people spend most of their lives (approximately 90%). It is therefore necessary to monitor and control indoor airborne microbes for occupational safety and public health. Most studies concerning airborne microorganisms have focused on fungi, with scant data available concerning bacteria. The present review considers papers published from 2010 to 2017 approximately and factors affecting properties of indoor airborne bacteria (communities and concentration) with respect to temporal perspective and to multiscale interaction viewpoint. From a temporal perspective, bacterial concentrations in built environments change depending on numbers of human occupancy, while properties of bacterial communities tend to remain stable. Similarly, the bacteria found in social and community spaces such as offices, classrooms and hospitals are mainly associated with human occupancy. Other major sources of indoor airborne bacteria are (i) outdoor environments, and (ii) the building materials themselves. Indoor bacterial communities and concentrations are varied with varying interferences by outdoor environment. Airborne bacteria from the outdoor environment enter an indoor space through open doors and windows, while indoor bacteria are simultaneously released to the outer environment. Outdoor bacterial communities and their concentrations are also affected by geographical factors such as types of land use and their spatial distribution. The bacteria found in built environments therefore originate from any of the natural and man-made surroundings around humans. Therefore, to better understand the factors influencing bacterial concentrations and communities in built environments, we should study all the environments that humans contact as a single ecosystem. In this review, we propose the establishment of a standard procedure for assessing properties of indoor airborne bacteria using four factors: temperature, relative humidity (RH), air exchange rate, and occupant density, as a minimum requirement. We also summarize the relevant legislation by country. Choice of factors to measure remain controversial are discussed.

  13. Transmission of Airborne Bacteria across Built Environments and Its Measurement Standards: A Review

    PubMed Central

    Fujiyoshi, So; Tanaka, Daisuke; Maruyama, Fumito

    2017-01-01

    Human health is influenced by various factors including microorganisms present in built environments where people spend most of their lives (approximately 90%). It is therefore necessary to monitor and control indoor airborne microbes for occupational safety and public health. Most studies concerning airborne microorganisms have focused on fungi, with scant data available concerning bacteria. The present review considers papers published from 2010 to 2017 approximately and factors affecting properties of indoor airborne bacteria (communities and concentration) with respect to temporal perspective and to multiscale interaction viewpoint. From a temporal perspective, bacterial concentrations in built environments change depending on numbers of human occupancy, while properties of bacterial communities tend to remain stable. Similarly, the bacteria found in social and community spaces such as offices, classrooms and hospitals are mainly associated with human occupancy. Other major sources of indoor airborne bacteria are (i) outdoor environments, and (ii) the building materials themselves. Indoor bacterial communities and concentrations are varied with varying interferences by outdoor environment. Airborne bacteria from the outdoor environment enter an indoor space through open doors and windows, while indoor bacteria are simultaneously released to the outer environment. Outdoor bacterial communities and their concentrations are also affected by geographical factors such as types of land use and their spatial distribution. The bacteria found in built environments therefore originate from any of the natural and man-made surroundings around humans. Therefore, to better understand the factors influencing bacterial concentrations and communities in built environments, we should study all the environments that humans contact as a single ecosystem. In this review, we propose the establishment of a standard procedure for assessing properties of indoor airborne bacteria using four factors: temperature, relative humidity (RH), air exchange rate, and occupant density, as a minimum requirement. We also summarize the relevant legislation by country. Choice of factors to measure remain controversial are discussed. PMID:29238327

  14. Polluted air--outdoors and indoors.

    PubMed

    Myers, I; Maynard, R L

    2005-09-01

    Many air pollutants which are considered important in ambient (outdoor) air are also found, sometimes at higher levels, in indoor air. With demanding standards having been set for many of these pollutants, both in the workplace and ambient air, consideration of the problems posed by indoor pollution is gaining pace. Studies on exposure to pollutants found in the indoor domestic environment are increasing and are contributing to an already significant compilation of datasets. Improvement in monitoring techniques has helped this process. Documented reports of fatalities from carbon monoxide poisonings are still worrying. However, studies on health effects of non-fatal, long term, low dose, indoor exposure to carbon monoxide and other pollutants, are still inconclusive and too infrequently documented. Of particular concern are the levels of air pollutants found in the domestic indoor environment in developing countries, despite simple interventions such as vented stoves having shown their value. Exposure to biomass smoke is still a level that would be considered unacceptable on health grounds in developed countries. As in the occupational environment, steps need to be taken to control the risks from exposure to the harmful constituents of indoor air in the home. However, the difficulty regarding regulation of the domestic indoor environment is its inherent privacy. Monitoring levels of pollutants in the home and ensuring regulations are adhered to, would likely prove difficult, especially when individual behaviour patterns and activities have the greatest influence on pollutant levels in indoor air. To this end, the Department of Health is developing guidance on indoor air pollution to encourage the reduction of pollutant levels in indoor domestic air. The importance of the effects of domestic indoor air on health and its contribution to the health of the worker are increasingly appreciated. Occupational physicians, by training and interest, are well placed to extend their interests into the environmental field and to focus on this important area.

  15. A review of semi-volatile organic compounds (SVOCs) in the indoor environment: occurrence in consumer products, indoor air and dust.

    PubMed

    Lucattini, Luisa; Poma, Giulia; Covaci, Adrian; de Boer, Jacob; Lamoree, Marja H; Leonards, Pim E G

    2018-06-01

    As many people spend a large part of their life indoors, the quality of the indoor environment is important. Data on contaminants such as flame retardants, pesticides and plasticizers are available for indoor air and dust but are scarce for consumer products such as computers, televisions, furniture, carpets, etc. This review presents information on semi-volatile organic compounds (SVOCs) in consumer products in an attempt to link the information available for chemicals in indoor air and dust with their indoor sources. A number of 256 papers were selected and divided among SVOCs found in consumer products (n = 57), indoor dust (n = 104) and air (n = 95). Concentrations of SVOCs in consumer products, indoor dust and air are reported (e.g. PFASs max: 13.9 μg/g in textiles, 5.8 μg/kg in building materials, 121 ng/g in house dust and 6.4 ng/m 3 in indoor air). Most of the studies show common aims, such as human exposure and risk assessment. The main micro-environments investigated (houses, offices and schools) reflect the relevance of indoor air quality. Most of the studies show a lack of data on concentrations of chemicals in consumer goods and often only the presence of chemicals is reported. At the moment this is the largest obstacle linking chemicals in products to chemicals detected in indoor air and dust. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. School Policies and Practices that Improve Indoor Air Quality

    ERIC Educational Resources Information Center

    Jones, Sherry Everett; Smith, Alisa M.; Wheeler, Lani S.; McManus, Tim

    2010-01-01

    Background: To determine whether schools with a formal indoor air quality management program were more likely than schools without a formal program to have policies and practices that promote superior indoor air quality. Methods: This study analyzed school-level data from the 2006 School Health Policies and Programs Study, a national study of…

  17. Particle size distribution and air pollution patterns in three urban environments in Xi'an, China.

    PubMed

    Niu, Xinyi; Guinot, Benjamin; Cao, Junji; Xu, Hongmei; Sun, Jian

    2015-10-01

    Three urban environments, office, apartment and restaurant, were selected to investigate the indoor and outdoor air quality as an inter-comparison in which CO2, particulate matter (PM) concentration and particle size ranging were concerned. In this investigation, CO2 level in the apartment (623 ppm) was the highest among the indoor environments and indoor levels were always higher than outdoor levels. The PM10 (333 µg/m(3)), PM2.5 (213 µg/m(3)), PM1 (148 µg/m(3)) concentrations in the office were 10-50% higher than in the restaurant and apartment, and the three indoor PM10 levels all exceeded the China standard of 150 µg/m(3). Particles ranging from 0.3 to 0.4 µm, 0.4 to 0.5 µm and 0.5 to 0.65 µm make largest contribution to particle mass in indoor air, and fine particles number concentrations were much higher than outdoor levels. Outdoor air pollution is mainly affected by heavy traffic, while indoor air pollution has various sources. Particularly, office environment was mainly affected by outdoor sources like soil dust and traffic emission; apartment particles were mainly caused by human activities; restaurant indoor air quality was affected by multiple sources among which cooking-generated fine particles and the human steam are main factors.

  18. Association of environment and policy characteristics on children's moderate-to-vigorous physical activity and time spent sedentary in afterschool programs.

    PubMed

    Ajja, Rahma; Clennin, Morgan N; Weaver, R Glenn; Moore, Justin B; Huberty, Jennifer L; Ward, Dianne S; Pate, Russell R; Beets, Michael W

    2014-12-01

    Afterschool programs are an important setting in which to promote children's physical activity. This study examines the association of environmental and policy characteristics on the moderate-to-vigorous physical activity and sedentary behavior of children attending afterschool programs. A total of 1302 children attending 20 afterschool programs across South Carolina wore accelerometers (ActiGraph GT3X+) for up to 4non-consecutive days. Policy-level characteristics were evaluated using the Healthy Afterschool Program Index-Physical Activity scale. Physical activity space was measured using a measuring wheel (indoor, ft(2)) and Geographical Information Systems software (outdoor, acres). The structure (free-play or organized) of activity opportunities was evaluated via direct observation. Time spent in moderate-to-vigorous physical activity and sedentary, both indoors and outdoors, was estimated using accelerometry. For every 5000 ft(2) of utilized indoor activity space an additional 2.4 and 3.3 min/day of sedentary behavior was observed among boys and girls, respectively. A higher ratio of free-play to organized play was associated with higher indoor sedentary behavior among boys and girls (3.9 min/day and 10.0 min/day, respectively). For every 1 acre of outdoor activity space used, an additional 2.7 min/day of moderate-to-vigorous physical activity was observed for boys. A higher free-play to organized play ratio was associated with higher outdoor moderate-to-vigorous physical activity for boys and girls (4.4 and 3.4 min/day increase, respectively). Policy characteristics were unrelated to moderate-to-vigorous physical activity levels and time spent sedentary. Findings indicate that policies and size of activity space had limited influence on moderate-to-vigorous physical activity and sedentary behavior, suggesting that a programmatic structure may be a more effective option to improve moderate-to-vigorous physical activity levels of children attending afterschool programs. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Research on the Implementation of Technological Measures for Controlling Indoor Environmental Quality in Green Residential Buildings

    NASA Astrophysics Data System (ADS)

    Wang, Ruozhu; Liu, Pengda; Qian, Yongmei

    2018-02-01

    This paper analyzes the design technology of controlling indoor quality in engineering practice, it is proposed that, in framework system of green residential building design, how to realize the design idea of controlling the indoor environment quality, and the design technology with feasibility, including the sunshine and lighting, indoor air quality and thermal environment, sound insulation and noise reduction measures, etc.. The results of all will provide a good theoretical supportting for the design of green residential building.

  20. Criegee intermediates in the indoor environment. New insights

    DOE PAGES

    Shallcross, D. E.; Taatjes, C. A.; Percival, C. J.

    2014-03-25

    Criegee intermediates are formed in the ozonolysis of alkenes and play an important role in indoor chemistry, notably as a source of OH radicals. Recent studies have shown that these Criegee intermediates react very quickly with NO 2, SO 2, and carbonyls, and in this study, steady-state calculations are used to inspect the potential impact of these data on indoor chemistry. It is shown that these reactions could accelerate NO 3 formation and SO 2 removal in the indoor environment significantly. In addition, reaction between Criegee intermediates and halogenated carbonyls could provide a significant loss process indoors, where currently onemore » does not exist.« less

  1. Real-time identification of indoor pollutant source positions based on neural network locator of contaminant sources and optimized sensor networks.

    PubMed

    Vukovic, Vladimir; Tabares-Velasco, Paulo Cesar; Srebric, Jelena

    2010-09-01

    A growing interest in security and occupant exposure to contaminants revealed a need for fast and reliable identification of contaminant sources during incidental situations. To determine potential contaminant source positions in outdoor environments, current state-of-the-art modeling methods use computational fluid dynamic simulations on parallel processors. In indoor environments, current tools match accidental contaminant distributions with cases from precomputed databases of possible concentration distributions. These methods require intensive computations in pre- and postprocessing. On the other hand, neural networks emerged as a tool for rapid concentration forecasting of outdoor environmental contaminants such as nitrogen oxides or sulfur dioxide. All of these modeling methods depend on the type of sensors used for real-time measurements of contaminant concentrations. A review of the existing sensor technologies revealed that no perfect sensor exists, but intensity of work in this area provides promising results in the near future. The main goal of the presented research study was to extend neural network modeling from the outdoor to the indoor identification of source positions, making this technology applicable to building indoor environments. The developed neural network Locator of Contaminant Sources was also used to optimize number and allocation of contaminant concentration sensors for real-time prediction of indoor contaminant source positions. Such prediction should take place within seconds after receiving real-time contaminant concentration sensor data. For the purpose of neural network training, a multizone program provided distributions of contaminant concentrations for known source positions throughout a test building. Trained networks had an output indicating contaminant source positions based on measured concentrations in different building zones. A validation case based on a real building layout and experimental data demonstrated the ability of this method to identify contaminant source positions. Future research intentions are focused on integration with real sensor networks and model improvements for much more complicated contamination scenarios.

  2. ENVIRONMENTAL TECHNOLOGY VERIFICATION FOR INDOOR AIR PRODUCTS

    EPA Science Inventory

    The paper discusses environmental technology verification (ETV) for indoor air products. RTI is developing the framework for a verification testing program for indoor air products, as part of EPA's ETV program. RTI is establishing test protocols for products that fit into three...

  3. Vitality of plants to live in the indoor environment

    NASA Astrophysics Data System (ADS)

    Shamsuri, Mohd Mahathir Suhaimi; Leman, A. M.; Hariri, Azian; Idris, Ahmad Fu'ad; Afandi, Azizi

    2017-09-01

    Indoor air quality (IAQ) is generally a public concern because 90% of people spend their time indoor. IAQ must be preserved wisely to guarantee the health of the building occupants. One of the ways to maintain the quality of air is by placing plants in the building. However, all plants come from the outdoor, and the environment is different compared to indoor. Environmental factors such as temperature and light will absolutely affect the growth of the plant. Light and temperature that are too bright or too deem can wither the plants. Nevertheless, certain plant is capable of adapting with different situation after assimilation process has been conducted. This study intends to analyze the capacity of seven selected plants (Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, Spider Plant, and Syngonium) to live in an indoor environment. The vitality of plants is based on photosynthetic level that is measured using leaf - chamber (LI-COR 6400). Two groups of plants were located in indoor and outdoor (indigenous location) setting, and were allowed to assimilate for two months before measurement were carried out. The results for the plant located indoor shows that only Spider Plant cannot perform photosynthesis under 300 lux, where the photosynthetic value remains negative. Meanwhile, other plants such as Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, and Syngonium that were left indoor showed similar 300 lux in which conform the ability of the plants to perform photosynthesis with the value of 0.3, 0.15, 0.35, 0.1, 0.15, and 0.1. In comparison, all of the plants that were stationed indoor and outdoor (except Spider Plant), the light compensation point (LCP) for indoor shows smaller value than the outdoor. This is because all the indoor plants had down - regulated their photosynthesis process by becoming more sensitive to light after their assimilation. From this study, it can be concluded that all plants except Spider Plant is able to live in indoor environment, and can be further studied to treat the indoor air.

  4. A structural regression model for relationship between indoor air quality with dissatisfaction of occupants in education environment

    NASA Astrophysics Data System (ADS)

    Hosseini, Hamid Reza; Yunos, Mohd Yazid Mohd; Ismail, Sumarni; Yaman, Maheran

    2017-12-01

    This paper analysis the effects of indoor air elements on the dissatisfaction of occupants in education of environments. Tries to find the equation model for increasing the comprehension about these affects and optimizes satisfaction of occupants about indoor environment. Subsequently, increase performance of students, lecturers and staffs. As the method, a satisfaction questionnaire (SQ) and measuring environment elements (MEE) was conducted, 143 respondents at five classrooms, four staff rooms and five lectures rooms were considered. Temperature, air velocity and humidity (TVH) were used as independent variables and dissatisfaction as dependent variable. The hypothesis was tested for significant relationship between variables, and analysis was applied. Results found that indoor air quality presents direct effects on dissatisfaction of occupants and indirect effects on performance and the highest effects fallowed by temperature. These results may help to optimize the quality of efficiency and effectiveness in education environments.

  5. Moving Environmental Justice Indoors: Understanding Structural Influences on Residential Exposure Patterns in Low-Income Communities

    PubMed Central

    Zota, Ami R.; Fabian, M. Patricia; Chahine, Teresa; Julien, Rhona; Spengler, John D.; Levy, Jonathan I.

    2011-01-01

    Objectives. The indoor environment has not been fully incorporated into the environmental justice dialogue. To inform strategies to reduce disparities, we developed a framework to identify the individual and place-based drivers of indoor environment quality. Methods. We reviewed empirical evidence of socioeconomic disparities in indoor exposures and key determinants of these exposures for air pollutants, lead, allergens, and semivolatile organic compounds. We also used an indoor air quality model applied to multifamily housing to illustrate how nitrogen dioxide (NO2) and fine particulate matter (PM2.5) vary as a function of factors known to be influenced by socioeconomic status. Results. Indoor concentrations of multiple pollutants are elevated in low-socioeconomic status households. Differences in these exposures are driven by the combined influences of indoor sources, outdoor sources, physical structures, and residential activity patterns. Simulation models confirmed indoor sources’ importance in determining indoor NO2 and PM2.5 exposures and showed the influence of household-specific determinants. Conclusions. Both theoretical models and empirical evidence emphasized that disparities in indoor environmental exposure can be significant. Understanding key determinants of multiple indoor exposures can aid in developing policies to reduce these disparities. PMID:21836112

  6. Exposure to airborne engineered nanoparticles in the indoor environment

    NASA Astrophysics Data System (ADS)

    Vance, Marina E.; Marr, Linsey C.

    2015-04-01

    This literature review assesses the current state of knowledge about inhalation exposure to airborne, engineered nanoparticles in the indoor environment. We present principal exposure scenarios in indoor environments, complemented by analysis of the published literature and of an inventory of nanotechnology-enhanced consumer products. Of all products listed in the inventory, 10.8% (194 products) present the potential for aerosolization of nanomaterials and subsequent inhalation exposure during use or misuse. Among those, silver-containing products are the most prevalent (68 products). Roughly 50% of products would release wet aerosols and 50% would potentially release dry aerosols. Approximately 14% are cleaning products that can be broadly used in public indoor environments, where building occupants may be exposed. While a variety of nanomaterial compositions have been investigated in the limited number of published release and exposure studies, we identified a need for studies investigating nanofibers (beyond carbon nanotubes), nanofilms, nanoplatelets, and other emerging nanomaterials such as ceria and their nanocomposites. Finally, we provide recommendations for future research to advance the understanding of exposure to airborne nanomaterials indoors, such as studies into indoor chemistry of nanomaterials, better nanomaterial reporting and labeling in consumer products, and safer design of nanomaterial-containing consumer products.

  7. Gender, airborne chemical monitoring, and physical work environment are related to indoor air symptoms among nonindustrial workers in the Klang Valley, Malaysia

    PubMed Central

    Syazwan, Aizat Ismail; Hafizan, Juahir; Baharudin, Mohd Rafee; Azman, Ahmad Zaid Fattah; Izwyn, Zulkapri; Zulfadhli, Ismail; Syahidatussyakirah, Katis

    2013-01-01

    Objectives: The purpose of this study was to analyze the relationship of airborne chemicals and the physical work environment risk element on the indoor air symptoms of nonindustrial workers. Design: A cross-sectional study consisting of 200 office workers. A random selection of 200 buildings was analyzed for exposure and indoor air symptoms based on a pilot study in the Klang Valley, Malaysia. Methods: A set of modified published questionnaires by the Department of Occupational Safety and Health (DOSH), Malaysia and a previous study (MM040NA questionnaire) pertaining to indoor air symptoms was used in the evaluation process of the indoor air symptoms. Statistical analyses involving logistic regression and linear regression were used to determine the relationship between exposure and indoor air symptoms for use in the development of an indoor risk matrix. Results: The results indicate that some indoor air pollutants (carbon monoxide, formaldehyde, total volatile organic compound, and dust) are related to indoor air symptoms of men and women. Temperature and relative humidity showed a positive association with complaints related to the perceived indoor environmental condition (drafts and inconsistency of temperature). Men predominantly reported general symptoms when stratification of gender involved exposure to formaldehyde. Women reported high levels of complaints related to mucosal and general symptoms from exposure to the dust level indoors. Conclusion: Exposure to pollutants (total volatile organic compounds, carbon monoxide, and formaldehyde) and physical stressors (air temperature and relative humidity) influence reported symptoms of office workers. These parameters should be focused upon and graded as one of the important elements in the grading procedure when qualitatively evaluating the indoor environment. PMID:23526736

  8. Gender, airborne chemical monitoring, and physical work environment are related to indoor air symptoms among nonindustrial workers in the Klang Valley, Malaysia.

    PubMed

    Syazwan, Aizat Ismail; Hafizan, Juahir; Baharudin, Mohd Rafee; Azman, Ahmad Zaid Fattah; Izwyn, Zulkapri; Zulfadhli, Ismail; Syahidatussyakirah, Katis

    2013-01-01

    The purpose of this study was to analyze the relationship of airborne chemicals and the physical work environment risk element on the indoor air symptoms of nonindustrial workers. A cross-sectional study consisting of 200 office workers. A random selection of 200 buildings was analyzed for exposure and indoor air symptoms based on a pilot study in the Klang Valley, Malaysia. A set of modified published questionnaires by the Department of Occupational Safety and Health (DOSH), Malaysia and a previous study (MM040NA questionnaire) pertaining to indoor air symptoms was used in the evaluation process of the indoor air symptoms. Statistical analyses involving logistic regression and linear regression were used to determine the relationship between exposure and indoor air symptoms for use in the development of an indoor risk matrix. The results indicate that some indoor air pollutants (carbon monoxide, formaldehyde, total volatile organic compound, and dust) are related to indoor air symptoms of men and women. Temperature and relative humidity showed a positive association with complaints related to the perceived indoor environmental condition (drafts and inconsistency of temperature). Men predominantly reported general symptoms when stratification of gender involved exposure to formaldehyde. Women reported high levels of complaints related to mucosal and general symptoms from exposure to the dust level indoors. Exposure to pollutants (total volatile organic compounds, carbon monoxide, and formaldehyde) and physical stressors (air temperature and relative humidity) influence reported symptoms of office workers. These parameters should be focused upon and graded as one of the important elements in the grading procedure when qualitatively evaluating the indoor environment.

  9. Reducing indoor residential exposures to outdoor pollutants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sherman, Max H.; Matson, Nance E.

    2003-07-01

    The basic strategy for providing indoor air quality in residences is to dilute indoor sources with outdoor air. This strategy assumes that the outdoor air does not have pollutants at harmful levels or that the outdoor air is, at least, less polluted than the indoor air. When this is not the case, different strategies need to be employed to ensure adequate air quality in the indoor environment. These strategies include ventilation systems, filtration and other measures. These strategies can be used for several types of outdoor pollution, including smog, particulates and toxic air pollutants. This report reviews the impacts thatmore » typical outdoor air pollutants can have on the indoor environment and provides design and operational guidance for mitigating them. Poor quality air cannot be used for diluting indoor contaminants, but more generally it can become an indoor contaminant itself. This paper discusses strategies that use the building as protection against potentially hazardous outdoor pollutants, including widespread pollutants, accidental events, and potential attacks.« less

  10. Analysis of indoor environmental quality influence toward occupants' work performance in Kompleks Eureka, USM

    NASA Astrophysics Data System (ADS)

    Zainon, Mohamad Rizal; Baharum, Faizal; Seng, Loh Yong

    2016-08-01

    The indoor environment much more important for people health and comfort than the outdoor environment. This scenario would make the performance of occupants at their work more important than energy costs in the building. So, this task is to upgrade indoor environmental quality conditions for comfort and work performance of occupants in Kompleks Eureka, USM while conserving energy of the building.. Recent studies have shown an important impact of the indoor thermal environment on occupants' work performance. Also studies on occupants medical leave show a very high loss of work time and working performance, which have important economical consequences for companies. The paper will mainly dealing with the indoor environmental qualities, such as thermal comfort level, air quality, lighting, and acoustic quality. The studies before showing that comfortable room temperatures, increased air ventilation above normal recommendation, comfortable acoustic surrounding will increases the work performance of occupants in Kompleks Eureka, USM.

  11. A coupled airflow and source/sink model for simulating indoor VOC exposures.

    PubMed

    Yang, X; Chen, Q

    2001-12-01

    In this paper, a numerical model is presented to study the indoor air quality (IAQ) in a room with different emission sources, sinks, and ventilation methods. A computer program, ACCESS-IAQ, is developed to simulate the airflow pattern, the time history of the contaminant concentrations in the occupied zone, and the inhalation exposures. The program developed may be useful for IAQ professional to design healthy and comfortable indoor environments. A numerical study has been carried out to predict the effectiveness of a displacement ventilation and a mixing ventilation on volatile organic compound (VOC) removal in a model office. Results from the numerical predictions show that when a "wet" emission source (a freshly painted wood stain) is distributed uniformly across the floor area with sinks (gypsum board) from the four vertical walls, displacement ventilation has consistently lower exposure at the breathing level of the occupant in the room. Such an effect is mainly due to the higher ventilation efficiency of displacement ventilation compared to the mixing ventilation. The simulation results also show that the walls adsorb significant amounts of VOCs during the first hour and act as secondary sources thereafter.

  12. Risk factors of indoor fall injuries in community-dwelling older women: a prospective cohort study.

    PubMed

    Hu, Jia; Xia, Qinghua; Jiang, Yu; Zhou, Peng; Li, Yuhua

    2015-01-01

    The aims of the study were to explore the characteristics and the potential risk factors of indoor fall injuries in community-dwelling older women, and to provide evidence for the future intervention strategy. A prospective cohort of 3043 women aged 60 years old and above from 3 selected counties in Shanghai was followed up on the outcomes of indoor fall injuries for up to 1 year. Demographic and health data were collected during admission; the physical function, balance ability and home-living environment were examined by a structured questionnaire when admitted. The outcome of indoor fall injury was investigated by a visit in month 3, month 6 and month 12 after baseline survey. Univariate analysis and Multiple Logistic Regression Model were used to examine the associations between potential risk factors and outcomes of indoor fall injuries. Two hundred and thirty-one of the 3043 women (7.6%) eventually suffered indoor fall injuries at least once during the 1-year follow-up. The injurious falls of women were significantly associated with age, educational level, marital status, health status, balance ability, physical activity and home-living environment in the univariate analyses. Women who worried about falls and restrained activities for it were more likely to suffer fall injury. Younger women, with less chronic disease, with good balance ability and living in good corridor environment, were less likely to receive fall injury in multiple logistic regression analyses. Multidimensional factors were associated with indoor fall injuries for community-dwelling older women. Proper clinical treatment of chronic disease and improvement of women's balance ability, as well as reducing the risk factor of indoor environment, which will play vital roles in preventing indoor fall injuries, should be prioritized for the intervention strategy. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Emergencies and IAQ

    EPA Pesticide Factsheets

    Preparation and response to weather-related and man-made emergencies is particularly important when it comes to indoor environments, since humans spend most of their time indoors, and rely on indoor spaces for shelter.

  14. Indoor localization using FM radio and DTMB signals

    NASA Astrophysics Data System (ADS)

    Wu, H.; Wang, Q.; Zhao, Y.; Ma, X.; Yang, M.; Liu, B.; Tang, R.; Xu, X.

    2016-07-01

    Indoor localization systems based on Wi-Fi signal strength fingerprinting techniques are widely used in office buildings. However, a general problem of these systems pertains to Wi-Fi signal degradation due to the environmental factors. And also, these systems cannot be used in the environments not covered with Wi-Fi signals or the environments with only a single Wi-Fi access point. In this paper, a new indoor location fingerprinting system using both FM radio and Digital Television Terrestrial Multimedia Broadcasting (DTMB) signals is proposed. First, the indoor location fingerprinting using FM radio and DTMB signals is theoretically analyzed to confirm its feasibility. Then, a specially designed combined strength fingerprinting location algorithm is proposed for the location system, which is achieved on the USRP2 platform. Finally, the system is tested in a typical indoor environment. The theoretical analysis and the tests show that the indoor location fingerprinting system using FM radio and DTMB signals has a similar localization accuracy to the Wi-Fi signal strength fingerprinting location system, while it has a wider coverage area, a lower maintenance cost, and more stable signal strength, which makes it a practical indoor positioning method.

  15. Long Term Hydrological (Radiological) Site Monitoring Data

    EPA Pesticide Factsheets

    Quality Data Asset includes all current and historical data on the quality of water with regard to the presence of water pollutants of all kinds regulated by the Clean Water Act. Under the new Interagency Agreement with the Department of Energy (DOE), the Radiation & Indoor Environments National Laboratory (R&IE), Office of Radiation and Indoor Air (ORIA), EPA, located in Las Vegas, NV, conducts a Long-Term Hydrological Monitoring Program (LTHMP) providing laboratory sampling/analysis and Quality Assurance and Control to measure radioactivity concentrations in the water sources near the sites of former underground nuclear explosions. The results of the LTHMP provide assurance that radioactive material from the tests have not migrated into water supplies.

  16. Cooperative Agreement Funding for Indoor Air Quality

    EPA Pesticide Factsheets

    The Indoor Environments Division has created partnership with public and private sector entities to help encourage the public to take action to minimize their risk and mitigate indoor air quality problems.

  17. Indoor and Outdoor Play in Preschool Programs

    ERIC Educational Resources Information Center

    Kroeker, Julia

    2017-01-01

    The purpose of this study was to explain children's indoor and outdoor play in preschool programs in terms of teacher interaction, peer interaction and task orientation. Children's indoor and outdoor play behaviors were compared using the Individualized Classroom Assessment Scoring System (inCLASS). Findings included significant differences on…

  18. Variation of indoor radon concentration and ambient dose equivalent rate in different outdoor and indoor environments.

    PubMed

    Stojanovska, Zdenka; Boev, Blazo; Zunic, Zora S; Ivanova, Kremena; Ristova, Mimoza; Tsenova, Martina; Ajka, Sorsa; Janevik, Emilija; Taleski, Vaso; Bossew, Peter

    2016-05-01

    Subject of this study is an investigation of the variations of indoor radon concentration and ambient dose equivalent rate in outdoor and indoor environments of 40 dwellings, 31 elementary schools and five kindergartens. The buildings are located in three municipalities of two, geologically different, areas of the Republic of Macedonia. Indoor radon concentrations were measured by nuclear track detectors, deployed in the most occupied room of the building, between June 2013 and May 2014. During the deploying campaign, indoor and outdoor ambient dose equivalent rates were measured simultaneously at the same location. It appeared that the measured values varied from 22 to 990 Bq/m(3) for indoor radon concentrations, from 50 to 195 nSv/h for outdoor ambient dose equivalent rates, and from 38 to 184 nSv/h for indoor ambient dose equivalent rates. The geometric mean value of indoor to outdoor ambient dose equivalent rates was found to be 0.88, i.e. the outdoor ambient dose equivalent rates were on average higher than the indoor ambient dose equivalent rates. All measured can reasonably well be described by log-normal distributions. A detailed statistical analysis of factors which influence the measured quantities is reported.

  19. Parent's Guide to School Indoor Air Quality. Revised

    ERIC Educational Resources Information Center

    Healthy Schools Network, Inc., 2012

    2012-01-01

    Air pollution is air pollution, indoors or out. Good indoor air quality (IAQ) contributes to a favorable learning environment for students, protects health, and supports the productivity of school personnel. In schools in poor repair, leaky roofs and crumbling walls have caused additional indoor air quality problems, including contamination with…

  20. Challenges in Flying Quadrotor Unmanned Aerial Vehicle for 3d Indoor Reconstruction

    NASA Astrophysics Data System (ADS)

    Yan, J.; Grasso, N.; Zlatanova, S.; Braggaar, R. C.; Marx, D. B.

    2017-09-01

    Three-dimensional modelling plays a vital role in indoor 3D tracking, navigation, guidance and emergency evacuation. Reconstruction of indoor 3D models is still problematic, in part, because indoor spaces provide challenges less-documented than their outdoor counterparts. Challenges include obstacles curtailing image and point cloud capture, restricted accessibility and a wide array of indoor objects, each with unique semantics. Reconstruction of indoor environments can be achieved through a photogrammetric approach, e.g. by using image frames, aligned using recurring corresponding image points (CIP) to build coloured point clouds. Our experiments were conducted by flying a QUAV in three indoor environments and later reconstructing 3D models which were analysed under different conditions. Point clouds and meshes were created using Agisoft PhotoScan Professional. We concentrated on flight paths from two vantage points: 1) safety and security while flying indoors and 2) data collection needed for reconstruction of 3D models. We surmised that the main challenges in providing safe flight paths are related to the physical configuration of indoor environments, privacy issues, the presence of people and light conditions. We observed that the quality of recorded video used for 3D reconstruction has a high dependency on surface materials, wall textures and object types being reconstructed. Our results show that 3D indoor reconstruction predicated on video capture using a QUAV is indeed feasible, but close attention should be paid to flight paths and conditions ultimately influencing the quality of 3D models. Moreover, it should be decided in advance which objects need to be reconstructed, e.g. bare rooms or detailed furniture.

  1. Test and analysis of indoor environment of dormitories of universities in autumn

    NASA Astrophysics Data System (ADS)

    Chen, Shijia

    2017-03-01

    In this paper, the indoor thermal and humid environment, luminous environment and acoustic environment of college dormitories in Baoding are tested and conducted a questionnaire survey. From the test, the subjective feelings and the objective evaluation parameters of the students in the dormitory were obtained. At last, the differences of thermal comfort, luminous environment and acoustic environment caused by students' different living habits and adaptability were analyzed.

  2. Indoor-breeding of Aedes albopictus in northern peninsular Malaysia and its potential epidemiological implications.

    PubMed

    Dieng, Hamady; Saifur, Rahman G M; Hassan, Ahmad Abu; Salmah, M R Che; Boots, Michael; Satho, Tomomitsu; Jaal, Zairi; AbuBakar, Sazaly

    2010-07-27

    The mosquito Ae. albopictus is usually adapted to the peri-domestic environment and typically breeds outdoors. However, we observed its larvae in most containers within homes in northern peninsular Malaysia. To anticipate the epidemiological implications of this indoor-breeding, we assessed some fitness traits affecting vectorial capacity during colonization process. Specifically, we examined whether Ae. albopictus exhibits increased survival, gonotrophic activity and fecundity due to the potential increase in blood feeding opportunities. In a series of experiments involving outdoors and indoors breeding populations, we found that Ae. albopictus lives longer in the indoor environment. We also observed increased nighttime biting activity and lifetime fecundity in indoor/domestic adapted females, although they were similar to recently colonized females in body size. Taken together these data suggest that accommodation of Ae. albopictus to indoor/domestic environment may increase its lifespan, blood feeding success, nuisance and thus vectorial capacity (both in terms of increased vector-host contacts and vector population density). These changes in the breeding behavior of Ae. albopictus, a potential vector of several human pathogens including dengue viruses, require special attention.

  3. CFD simulation research on residential indoor air quality.

    PubMed

    Yang, Li; Ye, Miao; He, Bao-Jie

    2014-02-15

    Nowadays people are excessively depending on air conditioning to create a comfortable indoor environment, but it could cause some health problems in a long run. In this paper, wind velocity field, temperature field and air age field in a bedroom with wall-hanging air conditioning running in summer are analyzed by CFD numerical simulation technology. The results show that wall-hanging air conditioning system can undertake indoor heat load and conduct good indoor thermal comfort. In terms of wind velocity, air speed in activity area where people sit and stand is moderate, most of which cannot feel wind flow and meet the summer indoor wind comfort requirement. However, for air quality, there are local areas without ventilation and toxic gases not discharged in time. Therefore it is necessary to take effective measures to improve air quality. Compared with the traditional measurement method, CFD software has many advantages in simulating indoor environment, so it is hopeful for humans to create a more comfortable, healthy living environment by CFD in the future. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Analysis of Indoor Environment in Classroom Based on Hygienic Requirements

    NASA Astrophysics Data System (ADS)

    Javorček, Miroslav; Sternová, Zuzana

    2016-06-01

    The article contains the analysis of experimental ventilation measurement in selected classrooms of the Elementary School Štrba. Mathematical model of selected classroom was prepared according to in-situ measurements and air exchange was calculated. Interior air temperature and quality influences the students ´ comfort. Evaluated data were compared to requirements of standard (STN EN 15251,2008) applicable to classroom indoor environment during lectures, highlighting the difference between required ambiance quality and actually measured values. CO2 concentration refers to one of the parameters indicating indoor environment quality.

  5. Breathe Deeply.

    ERIC Educational Resources Information Center

    Milshtein, Amy

    2000-01-01

    Discusses the special indoor air quality issues confronting school gyms, locker rooms, and pools; and explores ways to keep the indoor environment healthy. Included are discussions of mold and fungus control and air issues stemming from indoor pools. (GR)

  6. Location identification for indoor instantaneous point contaminant source by probability-based inverse Computational Fluid Dynamics modeling.

    PubMed

    Liu, X; Zhai, Z

    2008-02-01

    Indoor pollutions jeopardize human health and welfare and may even cause serious morbidity and mortality under extreme conditions. To effectively control and improve indoor environment quality requires immediate interpretation of pollutant sensor readings and accurate identification of indoor pollution history and source characteristics (e.g. source location and release time). This procedure is complicated by non-uniform and dynamic contaminant indoor dispersion behaviors as well as diverse sensor network distributions. This paper introduces a probability concept based inverse modeling method that is able to identify the source location for an instantaneous point source placed in an enclosed environment with known source release time. The study presents the mathematical models that address three different sensing scenarios: sensors without concentration readings, sensors with spatial concentration readings, and sensors with temporal concentration readings. The paper demonstrates the inverse modeling method and algorithm with two case studies: air pollution in an office space and in an aircraft cabin. The predictions were successfully verified against the forward simulation settings, indicating good capability of the method in finding indoor pollutant sources. The research lays a solid ground for further study of the method for more complicated indoor contamination problems. The method developed can help track indoor contaminant source location with limited sensor outputs. This will ensure an effective and prompt execution of building control strategies and thus achieve a healthy and safe indoor environment. The method can also assist the design of optimal sensor networks.

  7. Rio Blanco, Colorado, Long-Term Hydrologic Monitoring Program Sampling and Analysis Results for 2009

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2009-12-21

    The U.S. Department of Energy (DOE) Office of Legacy Management conducted annual sampling at the Rio Blanco, Colorado, Site, for the Long-Term Hydrologic Monitoring Program (LTHMP) on May 13 and 14, 2009. Samples were analyzed by the U.S. Environmental Protection Agency (EPA) Radiation&Indoor Environments National Laboratory in Las Vegas, Nevada. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectroscopy and tritium using the conventional and enriched methods.

  8. Factors influencing indoor air quality in an urban high rise apartment building (retitled as "Air Pollution and air exchange in an urban high rise apartment building")

    EPA Science Inventory

    The National Exposure Research Laboratory (NERL) Human Exposure and Atmospheric Sciences Division (HEASD) conducts research in support of EPA mission to protect human health and the environment. HEASD research program supports Goal 1 (Clean Air) and Goal 4 (Healthy People) of EP...

  9. Monitoring Indoor Air Quality for Enhanced Occupational Health.

    PubMed

    Pitarma, Rui; Marques, Gonçalo; Ferreira, Bárbara Roque

    2017-02-01

    Indoor environments are characterized by several pollutant sources. Because people spend more than 90% of their time in indoor environments, several studies have pointed out the impact of indoor air quality on the etiopathogenesis of a wide number of non-specific symptoms which characterizes the "Sick Building Syndrome", involving the skin, the upper and lower respiratory tract, the eyes and the nervous system, as well as many building related diseases. Thus, indoor air quality (IAQ) is recognized as an important factor to be controlled for the occupants' health and comfort. The majority of the monitoring systems presently available is very expensive and only allow to collect random samples. This work describes the system (iAQ), a low-cost indoor air quality monitoring wireless sensor network system, developed using Arduino, XBee modules and micro sensors, for storage and availability of monitoring data on a web portal in real time. Five micro sensors of environmental parameters (air temperature, humidity, carbon monoxide, carbon dioxide and luminosity) were used. Other sensors can be added for monitoring specific pollutants. The results reveal that the system can provide an effective indoor air quality assessment to prevent exposure risk. In fact, the indoor air quality may be extremely different compared to what is expected for a quality living environment. Systems like this would have benefit as public health interventions to reduce the burden of symptoms and diseases related to "sick buildings".

  10. Coordinate-Based Clustering Method for Indoor Fingerprinting Localization in Dense Cluttered Environments.

    PubMed

    Liu, Wen; Fu, Xiao; Deng, Zhongliang

    2016-12-02

    Indoor positioning technologies has boomed recently because of the growing commercial interest in indoor location-based service (ILBS). Due to the absence of satellite signal in Global Navigation Satellite System (GNSS), various technologies have been proposed for indoor applications. Among them, Wi-Fi fingerprinting has been attracting much interest from researchers because of its pervasive deployment, flexibility and robustness to dense cluttered indoor environments. One challenge, however, is the deployment of Access Points (AP), which would bring a significant influence on the system positioning accuracy. This paper concentrates on WLAN based fingerprinting indoor location by analyzing the AP deployment influence, and studying the advantages of coordinate-based clustering compared to traditional RSS-based clustering. A coordinate-based clustering method for indoor fingerprinting location, named Smallest-Enclosing-Circle-based (SEC), is then proposed aiming at reducing the positioning error lying in the AP deployment and improving robustness to dense cluttered environments. All measurements are conducted in indoor public areas, such as the National Center For the Performing Arts (as Test-bed 1) and the XiDan Joy City (Floors 1 and 2, as Test-bed 2), and results show that SEC clustering algorithm can improve system positioning accuracy by about 32.7% for Test-bed 1, 71.7% for Test-bed 2 Floor 1 and 73.7% for Test-bed 2 Floor 2 compared with traditional RSS-based clustering algorithms such as K-means.

  11. Coordinate-Based Clustering Method for Indoor Fingerprinting Localization in Dense Cluttered Environments

    PubMed Central

    Liu, Wen; Fu, Xiao; Deng, Zhongliang

    2016-01-01

    Indoor positioning technologies has boomed recently because of the growing commercial interest in indoor location-based service (ILBS). Due to the absence of satellite signal in Global Navigation Satellite System (GNSS), various technologies have been proposed for indoor applications. Among them, Wi-Fi fingerprinting has been attracting much interest from researchers because of its pervasive deployment, flexibility and robustness to dense cluttered indoor environments. One challenge, however, is the deployment of Access Points (AP), which would bring a significant influence on the system positioning accuracy. This paper concentrates on WLAN based fingerprinting indoor location by analyzing the AP deployment influence, and studying the advantages of coordinate-based clustering compared to traditional RSS-based clustering. A coordinate-based clustering method for indoor fingerprinting location, named Smallest-Enclosing-Circle-based (SEC), is then proposed aiming at reducing the positioning error lying in the AP deployment and improving robustness to dense cluttered environments. All measurements are conducted in indoor public areas, such as the National Center For the Performing Arts (as Test-bed 1) and the XiDan Joy City (Floors 1 and 2, as Test-bed 2), and results show that SEC clustering algorithm can improve system positioning accuracy by about 32.7% for Test-bed 1, 71.7% for Test-bed 2 Floor 1 and 73.7% for Test-bed 2 Floor 2 compared with traditional RSS-based clustering algorithms such as K-means. PMID:27918454

  12. Report: Results of Technical Network Vulnerability Assessment: EPA’s Radiation and Indoor Environments National Laboratory

    EPA Pesticide Factsheets

    Report #09-P-0053, December 9, 2008. Vulnerability testing of EPA’s Radiation and Indoor Environments National Laboratory (R&IEN) network identified Internet Protocol addresses with medium-risk vulnerabilities.

  13. The Airborne Metagenome in an Indoor Urban Environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tringe, Susannah; Zhang, Tao; Liu, Xuguo

    2008-02-12

    The indoor atmosphere is an ecological unit that impacts on public health. To investigate the composition of organisms in this space, we applied culture-independent approaches to microbes harvested from the air of two densely populated urban buildings, from which we analyzed 80 megabases genomic DNA sequence and 6000 16S rDNA clones. The air microbiota is primarily bacteria, including potential opportunistic pathogens commonly isolated from human-inhabited environments such as hospitals, but none of the data contain matches to virulent pathogens or bioterror agents. Comparison of air samples with each other and nearby environments suggested that the indoor air microbes are notmore » random transients from surrounding outdoor environments, but rather originate from indoor niches. Sequence annotation by gene function revealed specific adaptive capabilities enriched in the air environment, including genes potentially involved in resistance to desiccation and oxidative damage. This baseline index of air microbiota will be valuable for improving designs of surveillance for natural or man-made release of virulent pathogens.« less

  14. The Airborne Metagenome in an Indoor Urban Environment

    PubMed Central

    Liu, Xuguo; Yu, Yiting; Lee, Wah Heng; Yap, Jennifer; Yao, Fei; Suan, Sim Tiow; Ing, Seah Keng; Haynes, Matthew; Rohwer, Forest; Wei, Chia Lin; Tan, Patrick; Bristow, James; Rubin, Edward M.; Ruan, Yijun

    2008-01-01

    The indoor atmosphere is an ecological unit that impacts on public health. To investigate the composition of organisms in this space, we applied culture-independent approaches to microbes harvested from the air of two densely populated urban buildings, from which we analyzed 80 megabases genomic DNA sequence and 6000 16S rDNA clones. The air microbiota is primarily bacteria, including potential opportunistic pathogens commonly isolated from human-inhabited environments such as hospitals, but none of the data contain matches to virulent pathogens or bioterror agents. Comparison of air samples with each other and nearby environments suggested that the indoor air microbes are not random transients from surrounding outdoor environments, but rather originate from indoor niches. Sequence annotation by gene function revealed specific adaptive capabilities enriched in the air environment, including genes potentially involved in resistance to desiccation and oxidative damage. This baseline index of air microbiota will be valuable for improving designs of surveillance for natural or man-made release of virulent pathogens. PMID:18382653

  15. [Environmental quality: wellfare, confort and health].

    PubMed

    Vargas Marcos, Francisco; Gallego Pulgarín, Isabel

    2005-01-01

    Different ways of interpreting environmental conditions have led to the development of concepts such as the sick building, indoor air quality or indoor environment quality, for understanding the complexity of the pollutants in enclosed environments and the implications thereof on the health. The "Indoor Environment Quality" proposal is an advancement, operative and conceptual, surpassing amply prior ones, given that it orients the actions toward healthy environments without limiting the idea of pollution to the air alone. The aim is identifying the competence to preventing hazards related to exposure to pollutants within the confines of indoor environments and know the legislative framework useful for taking the actions. Optimum conditions within indoor environments must redound in health, well-being and comfort with regard to both working life as well as the environments in which everyday activities outside of work, extracurricular, leisure-time and entertainment activities are carried out. Today's society is demanding safe, clean, well-climatized places, for this is necessary to integrate the inhabitant's perceptions and demands and achieve an optimum balance among social standards, energy use and sustainable development. Legislation is being further expanded upon in the direction of occupational health and safety and the regulation of chemical substances. Environmental Health carries out prevention and control tasks, takes part in the enforcement of international pollution and waste reduction agreements and promotes measures for carrying out the European Environment and Health Strategy. It is considered useful the elaboration of protocols for the evaluation and administration gives the risks associated to the interior pollutants.

  16. Impacts of Earthquake Aftermath on Indoor Carbon Monoxide Levels in Turkish Coffeehouses Environment in Duzce, Turkey

    PubMed Central

    Bahcebasi, T; Guler, C; Kandis, H; Kara, İ H

    2012-01-01

    Background: In 1999, Duzce suffered two consecutive devastating earthquakes above magnitude 7 in August and November. In the present study, we aimed to evaluate the indoor air quality of coffeehouses by determining carbon monoxide (CO) levels and their contributing factors in coffeehouses built before and after the earthquake. Methods: We conducted our study in 76 Turkish coffeehouses in Duzce in winter (November 2007–March 2008) during rush hours (18:00–23:00). The Turkish coffeehouses included in the study were evaluated under four categories based on smoking status and construction date. The characteristics of the coffeehouses, such as their CO levels and temperatures both indoors and outdoors, were all measured. These analyses were carried out with the SPSS 15.0 program. Results: The CO levels in Turkish coffeehouses were above the values indicated as being safe by the WHO. While stoves and cooking equipment were determined to contribute to indoor CO levels, cigarettes were found to be the main source. Indoor CO levels at second hour were very strongly correlated (r: 0.84, P<0.001) (r: 0.91, P<0.001) with indoor CO levels at initial and first hour as well as with smoking status (r: 0.69, P<0.001); they were also moderately correlated with the room volume (r: 0.34, P<0.001) and construction materials (r: 0.31, P<0.001) of the coffeehouse. Conclusion: Elevated CO levels in Turkish coffeehouses indicate the possible presence of other pollutants, particularly when the main source is smoking. In such cases, both individuals and the whole of society are affected negatively in many ways. Therefore, smoking should be prohibited by law in Turkish coffeehouses and national awareness programs should be developed based on peoples’ lifestyles. Moreover, the standards for construction and management of Turkish coffeehouses should be improved as well. PMID:23113122

  17. Programming an Artificial Neural Network Tool for Spatial Interpolation in GIS - A Case Study for Indoor Radio Wave Propagation of WLAN.

    PubMed

    Sen, Alper; Gümüsay, M Umit; Kavas, Aktül; Bulucu, Umut

    2008-09-25

    Wireless communication networks offer subscribers the possibilities of free mobility and access to information anywhere at any time. Therefore, electromagnetic coverage calculations are important for wireless mobile communication systems, especially in Wireless Local Area Networks (WLANs). Before any propagation computation is performed, modeling of indoor radio wave propagation needs accurate geographical information in order to avoid the interruption of data transmissions. Geographic Information Systems (GIS) and spatial interpolation techniques are very efficient for performing indoor radio wave propagation modeling. This paper describes the spatial interpolation of electromagnetic field measurements using a feed-forward back-propagation neural network programmed as a tool in GIS. The accuracy of Artificial Neural Networks (ANN) and geostatistical Kriging were compared by adjusting procedures. The feedforward back-propagation ANN provides adequate accuracy for spatial interpolation, but the predictions of Kriging interpolation are more accurate than the selected ANN. The proposed GIS ensures indoor radio wave propagation model and electromagnetic coverage, the number, position and transmitter power of access points and electromagnetic radiation level. Pollution analysis in a given propagation environment was done and it was demonstrated that WLAN (2.4 GHz) electromagnetic coverage does not lead to any electromagnetic pollution due to the low power levels used. Example interpolated electromagnetic field values for WLAN system in a building of Yildiz Technical University, Turkey, were generated using the selected network architectures to illustrate the results with an ANN.

  18. Programming an Artificial Neural Network Tool for Spatial Interpolation in GIS - A Case Study for Indoor Radio Wave Propagation of WLAN

    PubMed Central

    Şen, Alper; Gümüşay, M. Ümit; Kavas, Aktül; Bulucu, Umut

    2008-01-01

    Wireless communication networks offer subscribers the possibilities of free mobility and access to information anywhere at any time. Therefore, electromagnetic coverage calculations are important for wireless mobile communication systems, especially in Wireless Local Area Networks (WLANs). Before any propagation computation is performed, modeling of indoor radio wave propagation needs accurate geographical information in order to avoid the interruption of data transmissions. Geographic Information Systems (GIS) and spatial interpolation techniques are very efficient for performing indoor radio wave propagation modeling. This paper describes the spatial interpolation of electromagnetic field measurements using a feed-forward back-propagation neural network programmed as a tool in GIS. The accuracy of Artificial Neural Networks (ANN) and geostatistical Kriging were compared by adjusting procedures. The feedforward back-propagation ANN provides adequate accuracy for spatial interpolation, but the predictions of Kriging interpolation are more accurate than the selected ANN. The proposed GIS ensures indoor radio wave propagation model and electromagnetic coverage, the number, position and transmitter power of access points and electromagnetic radiation level. Pollution analysis in a given propagation environment was done and it was demonstrated that WLAN (2.4 GHz) electromagnetic coverage does not lead to any electromagnetic pollution due to the low power levels used. Example interpolated electromagnetic field values for WLAN system in a building of Yildiz Technical University, Turkey, were generated using the selected network architectures to illustrate the results with an ANN. PMID:27873854

  19. Feasibility study on mental healthcare using indoor plants for office workers

    NASA Astrophysics Data System (ADS)

    Kubota, Tsuyoshi; Matsumoto, Hiroshi; Genjo, Kaori; Nakano, Takaoki

    2017-10-01

    In recent years, it has become a problem that office workers' stresses affect their intellectual productivity. As one of strategies mitigating the stress while working, many studies on the effect of indoor plants introduced into the office have been conducted. The psychological and physiological effects of indoor plants have been expected to mitigate the office workers' stresses. Also, the effects of green amenities such as improvement of productivity, control of the indoor thermal environment, relaxation and recovery of visual fatigue, and improvement of air quality have been expected. In this study, a field investigation on the green amenity effects of indoor plants on office workers' psychological and physiological responses in an actual office was conducted and discussed. This paper describes the measurement results of the physical environment and workers' psychological and physiological responses under the condition with shelves installed with indoor plants in an office room. It was suggested that indoor plants such as mint, basil and begonia, and a combination of red and green plants were effective for mitigating worker's stresses.

  20. Source apportionment of indoor air pollution

    NASA Astrophysics Data System (ADS)

    Sexton, Ken; Hayward, Steven B.

    An understanding of the relative contributions from important pollutant sources to human exposures is necessary for the design and implementation of effective control strategies. In the past, societal efforts to control air pollution have focused almost exclusively on the outdoor (ambient) environment. As a result, substantial amounts of time and money have been spent to limit airborne discharges from mobile and stationary sources. Yet it is now recognized that exposures to elevated pollutant concentrations often occur as a result of indoor, rather than outdoor, emissions. While the major indoor sources have been identified, their relative impacts on indoor air quality have not been well defined. Application of existing source apportionment models to nonindustrial indoor environments is only just beginning. It is possible that these models might be used to distinguish between indoor and outdoor emissions, as well as to distinguish among indoor sources themselves. However, before the feasibility and suitability of source-apportionment methods for indoor applications can be assessed adequately, it is necessary to take account of model assumptions and associated data requirements. This paper examines the issue of indoor source apportionment and reviews the need for emission characterization studies to support such source-apportionment efforts.

  1. Parents and Students and Healthy Indoor School Environments

    EPA Pesticide Factsheets

    School-aged children spend a great deal of time inside school buildings. Parents can play an important role in creating healthy indoor school environments. Parents and students alike can make a powerful case for protecting health in schools.

  2. Particulate matter from indoor environments of classroom induced higher cytotoxicity and leakiness in human microvascular endothelial cells in comparison with those collected from corridor.

    PubMed

    Chua, M L; Setyawati, M I; Li, H; Fang, C H Y; Gurusamy, S; Teoh, F T L; Leong, D T; George, S

    2017-05-01

    We investigated the physicochemical properties (size, shape, elemental composition, and endotoxin) of size resolved particulate matter (PM) collected from the indoor and corridor environments of classrooms. A comparative hazard profiling of these PM was conducted using human microvascular endothelial cells (HMVEC). Oxidative stress-dependent cytotoxicity responses were assessed using quantitative reverse transcriptase polymerase chain reaction (RT-PCR) and high content screening (HCS), and disruption of monolayer cell integrity was assessed using fluorescence microscopy and transwell assay. Scanning electron microscopy (SEM) coupled with energy-dispersive X-ray spectroscopy (EDX) analysis showed differences in the morphology and elemental composition of PM of different sizes and origins. While the total mass of PM collected from indoor environment was lower in comparison with those collected from the corridor, the endotoxin content was substantially higher in indoor PM (e.g., ninefold higher endotoxin level in indoor PM 8.1-20 ). The ability to induce oxidative stress-mediated cytotoxicity and leakiness in cell monolayer were higher for indoor PM compared to those collected from the corridor. In conclusion, this comparative analysis suggested that indoor PM is relatively more hazardous to the endothelial system possibly because of higher endotoxin content. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Architectural design influences the diversity and structure of the built environment microbiome

    PubMed Central

    Kembel, Steven W; Jones, Evan; Kline, Jeff; Northcutt, Dale; Stenson, Jason; Womack, Ann M; Bohannan, Brendan JM; Brown, G Z; Green, Jessica L

    2012-01-01

    Buildings are complex ecosystems that house trillions of microorganisms interacting with each other, with humans and with their environment. Understanding the ecological and evolutionary processes that determine the diversity and composition of the built environment microbiome—the community of microorganisms that live indoors—is important for understanding the relationship between building design, biodiversity and human health. In this study, we used high-throughput sequencing of the bacterial 16S rRNA gene to quantify relationships between building attributes and airborne bacterial communities at a health-care facility. We quantified airborne bacterial community structure and environmental conditions in patient rooms exposed to mechanical or window ventilation and in outdoor air. The phylogenetic diversity of airborne bacterial communities was lower indoors than outdoors, and mechanically ventilated rooms contained less diverse microbial communities than did window-ventilated rooms. Bacterial communities in indoor environments contained many taxa that are absent or rare outdoors, including taxa closely related to potential human pathogens. Building attributes, specifically the source of ventilation air, airflow rates, relative humidity and temperature, were correlated with the diversity and composition of indoor bacterial communities. The relative abundance of bacteria closely related to human pathogens was higher indoors than outdoors, and higher in rooms with lower airflow rates and lower relative humidity. The observed relationship between building design and airborne bacterial diversity suggests that we can manage indoor environments, altering through building design and operation the community of microbial species that potentially colonize the human microbiome during our time indoors. PMID:22278670

  4. Comparison of Air Impaction and Electrostatic Dust Collector Sampling Methods to Assess Airborne Fungal Contamination in Public Buildings.

    PubMed

    Normand, Anne-Cécile; Ranque, Stéphane; Cassagne, Carole; Gaudart, Jean; Sallah, Kankoé; Charpin, Denis-André; Piarroux, Renaud

    2016-03-01

    Many ailments can be linked to exposure to indoor airborne fungus. However, obtaining a precise measurement of airborne fungal levels is complicated partly due to indoor air fluctuations and non-standardized techniques. Electrostatic dust collector (EDC) sampling devices have been used to measure a wide range of airborne analytes, including endotoxins, allergens, β-glucans, and microbial DNA in various indoor environments. In contrast, viable mold contamination has only been assessed in highly contaminated environments such as farms and archive buildings. This study aimed to assess the use of EDCs, compared with repeated air-impactor measurements, to assess airborne viable fungal flora in moderately contaminated indoor environments. Indoor airborne fungal flora was cultured from EDCs and daily air-impaction samples collected in an office building and a daycare center. The quantitative fungal measurements obtained using a single EDC significantly correlated with the cumulative measurement of nine daily air impactions. Both methods enabled the assessment of fungal exposure, although a few differences were observed between the detected fungal species and the relative quantity of each species. EDCs were also used over a 32-month period to monitor indoor airborne fungal flora in a hospital office building, which enabled us to assess the impact of outdoor events (e.g. ground excavations) on the fungal flora levels on the indoor environment. In conclusion, EDC-based measurements provided a relatively accurate profile of the viable airborne flora present during a sampling period. In particular, EDCs provided a more representative assessment of fungal levels compared with single air-impactor sampling. The EDC technique is also simpler than performing repetitive air-impaction measures over the course of several consecutive days. EDC is a versatile tool for collecting airborne samples and was efficient for measuring mold levels in indoor environments. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  5. Using Openstreetmap Data to Generate Building Models with Their Inner Structures for 3d Maps

    NASA Astrophysics Data System (ADS)

    Wang, Z.; Zipf, A.

    2017-09-01

    With the development of Web 2.0, more and more data related to indoor environments has been collected within the volunteered geographic information (VGI) framework, which creates a need for construction of indoor environments from VGI. In this study, we focus on generating 3D building models from OpenStreetMap (OSM) data, and provide an approach to support construction and visualization of indoor environments on 3D maps. In this paper, we present an algorithm which can extract building information from OSM data, and can construct building structures as well as inner building components (e.g., doors, rooms, and windows). A web application is built to support the processing and visualization of the building models on a 3D map. We test our approach with an indoor dataset collected from the field. The results show the feasibility of our approach and its potentials to provide support for a wide range of applications, such as indoor and outdoor navigation, urban planning, and incident management.

  6. Application of zonal model on indoor air sensor network design

    NASA Astrophysics Data System (ADS)

    Chen, Y. Lisa; Wen, Jin

    2007-04-01

    Growing concerns over the safety of the indoor environment have made the use of sensors ubiquitous. Sensors that detect chemical and biological warfare agents can offer early warning of dangerous contaminants. However, current sensor system design is more informed by intuition and experience rather by systematic design. To develop a sensor system design methodology, a proper indoor airflow modeling approach is needed. Various indoor airflow modeling techniques, from complicated computational fluid dynamics approaches to simplified multi-zone approaches, exist in the literature. In this study, the effects of two airflow modeling techniques, multi-zone modeling technique and zonal modeling technique, on indoor air protection sensor system design are discussed. Common building attack scenarios, using a typical CBW agent, are simulated. Both multi-zone and zonal models are used to predict airflows and contaminant dispersion. Genetic Algorithm is then applied to optimize the sensor location and quantity. Differences in the sensor system design resulting from the two airflow models are discussed for a typical office environment and a large hall environment.

  7. Assessment of Indoor Air Quality Problems in Office-Like Environments: Role of Occupational Health Services.

    PubMed

    Carrer, Paolo; Wolkoff, Peder

    2018-04-12

    There is an increasing concern about indoor air quality (IAQ) and its impact on health, comfort, and work-performance in office-like environments and their workers, which account for most of the labor force. The Scientific Committee on Indoor Air Quality and Health of the ICOH (Int. Comm. Occup. Health) has discussed the assessment and management of IAQ problems and proposed a stepwise approach to be conducted by a multidisciplinary team. It is recommended to integrate the building assessment, inspection by walk-through of the office workplace, questionnaire survey, and environmental measurements, in that order. The survey should cover perceived IAQ, symptoms, and psychosocial working aspects. The outcome can be used for mapping the IAQ and to prioritize the order in which problems should be dealt with. Individual health surveillance in relation to IAQ is proposed only when periodical health surveillance is already performed for other risks (e.g., video display units) or when specific clinical examination of workers is required due to the occurrence of diseases that may be linked to IAQ (e.g., Legionnaire's disease), recurrent inflammation, infections of eyes, respiratory airway effects, and sensorial disturbances. Environmental and personal risk factors should also be compiled and assessed. Workplace health promotion should include programs for smoking cessation and stress and IAQ management.

  8. Assessment of Indoor Air Quality Problems in Office-Like Environments: Role of Occupational Health Services

    PubMed Central

    2018-01-01

    There is an increasing concern about indoor air quality (IAQ) and its impact on health, comfort, and work-performance in office-like environments and their workers, which account for most of the labor force. The Scientific Committee on Indoor Air Quality and Health of the ICOH (Int. Comm. Occup. Health) has discussed the assessment and management of IAQ problems and proposed a stepwise approach to be conducted by a multidisciplinary team. It is recommended to integrate the building assessment, inspection by walk-through of the office workplace, questionnaire survey, and environmental measurements, in that order. The survey should cover perceived IAQ, symptoms, and psychosocial working aspects. The outcome can be used for mapping the IAQ and to prioritize the order in which problems should be dealt with. Individual health surveillance in relation to IAQ is proposed only when periodical health surveillance is already performed for other risks (e.g., video display units) or when specific clinical examination of workers is required due to the occurrence of diseases that may be linked to IAQ (e.g., Legionnaire’s disease), recurrent inflammation, infections of eyes, respiratory airway effects, and sensorial disturbances. Environmental and personal risk factors should also be compiled and assessed. Workplace health promotion should include programs for smoking cessation and stress and IAQ management. PMID:29649167

  9. Microbiological quality of indoor air in university libraries.

    PubMed

    Hayleeyesus, Samuel Fekadu; Manaye, Abayneh Melaku

    2014-05-01

    To evaluate the concentration of bacteria and fungi in the indoor environment of Jimma University libraries, so as to estimate the health hazard and to create standards for indoor air quality control. The microbial quality of indoor air of eight libraries of Jimma University was determined. The settle plate method using open Petri-dishes containing different culture media was employed to collect sample twice daily. Isolates were identified according to standard methods. The concentrations of bacteria and fungi aerosols in the indoor environment of the university libraries ranged between 367-2595 CFU/m(3). According to the sanitary standards classification of European Commission, almost all the libraries indoor air of Jimma University was heavily contaminated with bacteria and fungi. In spite of their major source difference, the average fungi density found in the indoor air of libraries did appear to follow the same trend with bacterial density (P=0.001). The bacteria isolates included Micrococcus sp., Staphylococcus aureus, Streptococcus pyogenes, Bacillus sp. and Neisseria sp. while Cladosporium sp., Alternaria sp., Penicillium sp. and Aspergillus sp. were the most isolated fungi. The indoor air of all libraries were in the range above highly contaminated according to European Commission classification and the most isolates are considered as potential candidates involved in the establishment of sick building syndromes and often associated with clinical manifestations like allergy, rhinitis, asthma and conjunctivitis. Thus, attention must be given to control those environmental factors which favor the growth and multiplication of microbes in indoor environment of libraries to safeguard the health of users and workers.

  10. Image-Based Localization for Indoor Environment Using Mobile Phone

    NASA Astrophysics Data System (ADS)

    Huang, Y.; Wang, H.; Zhan, K.; Zhao, J.; Gui, P.; Feng, T.

    2015-05-01

    Real-time indoor localization based on supporting infrastructures like wireless devices and QR codes are usually costly and labor intensive to implement. In this study, we explored a cheap alternative approach based on images for indoor localization. A user can localize him/herself by just shooting a photo of the surrounding indoor environment using the mobile phone. No any other equipment is required. This is achieved by employing image-matching and searching techniques with a dataset of pre-captured indoor images. In the beginning, a database of structured images of the indoor environment is constructed by using image matching and the bundle adjustment algorithm. Then each image's relative pose (its position and orientation) is estimated and the semantic locations of images are tagged. A user's location can then be determined by comparing a photo taken by the mobile phone to the database. This is done by combining quick image searching, matching and the relative orientation. This study also try to explore image acquisition plans and the processing capacity of off-the-shell mobile phones. During the whole pipeline, a collection of indoor images with both rich and poor textures are examined. Several feature detectors are used and compared. Pre-processing of complex indoor photo is also implemented on the mobile phone. The preliminary experimental results prove the feasibility of this method. In the future, we are trying to raise the efficiency of matching between indoor images and explore the fast 4G wireless communication to ensure the speed and accuracy of the localization based on a client-server framework.

  11. RESEARCH & DEVELOPMENT OF PREVENTION AND CONTROL MEASURES FOR MOLD CONTAMINATION

    EPA Science Inventory

    The U.S. Environmental Protection Agency, Air Pollution Prevention and Control Division, Indoor Environment Management Branch has, since 1995, conducted research into controlling biological contamination in the indoor environment. In this paper four areas of research are discusse...

  12. TESTING ANTIMICROBIAL EFFICACY ON POROUS MATERIALS

    EPA Science Inventory

    The efficacy of antimicrobial treatments to eliminate or control biological growth in the indoor environment can easily be tested on nonporous surfaces. However, the testing of antimicrobial efficacy on porous surfaces, such as those found in the indoor environment [i.e., gypsum ...

  13. Airborne viable fungi in school environments in different climatic regions - A review

    NASA Astrophysics Data System (ADS)

    Salonen, Heidi; Duchaine, Caroline; Mazaheri, Mandana; Clifford, Sam; Lappalainen, Sanna; Reijula, Kari; Morawska, Lidia

    2015-03-01

    Elevated levels of fungi in indoor environments have been linked with mould/moisture damage in building structures. However, there is a lack of information about "normal" concentrations and flora as well as guidelines of viable fungi in the school environment in different climatic conditions. We have reviewed existing guidelines for indoor fungi and the current knowledge of the concentrations and flora of viable fungi in different climatic areas, the impact of the local factors on concentrations and flora of viable fungi in school environments. Meta-regression was performed to estimate the average behaviour for each analysis of interest, showing wide variation in the mean concentrations in outdoor and indoor school environments (range: 101-103 cfu/m3). These concentrations were significantly higher for both outdoors and indoors in the moderate than in the continental climatic area, showing that the climatic condition was a determinant for the concentrations of airborne viable fungi. The most common fungal species both in the moderate and continental area were Cladosporium spp. and Penicillium spp. The suggested few quantitative guidelines for indoor air viable fungi for school buildings are much lower than for residential areas. This review provides a synthesis, which can be used to guide the interpretation of the fungi measurements results and help to find indications of mould/moisture in school building structures.

  14. Comparison, association, and risk assessment of phthalates in floor dust at different indoor environments in Delaware, USA.

    PubMed

    Bi, Xiaolong; Yuan, Shoujun; Pan, Xiaojun; Winstead, Cherese; Wang, Qiquan

    2015-01-01

    This study aimed to compare and assess phthalate contamination in various indoor environments. In this study, 44 floor dust samples from different indoor environments in Delaware, USA were collected and analyzed for 14 phthalates using gas chromatography-mass spectrometry. Phthalates were detected in all dust samples with the total concentration ranging from 84 to 7117 mg kg(-1). DEHP (di-2-ethylhexyl phthalate), BzBP (benzylbutyl phthalate), DBP (dibutyl phthalate), and DiBP (di-isobutyl phthalate) were both the most frequently and abundantly detected phthalates. The average concentration of total phthalates in dust from offices, student dorms, gyms, stores, and daycare centers was found to be significantly or insignificantly (P = 0.05) higher than that in dust from houses and apartments. Plastic flooring materials and the application of floor care chemical products were positively associated with total phthalate concentration in floor dust. Toxicological risk assessment indicated that an investigated daycare center in this study was the only indoor environment that may cause the intake amount of DEHP of infants, toddlers, and children via dust ingestion to exceed the reference dose established by the U.S. Environmental Protection Agency (USEPA). Regular monitoring on phthalate contamination in sensitive indoor environments is recommended.

  15. Current Indoor Air Quality in Japan.

    PubMed

    Jinno, Hideto

    2016-01-01

    People spend more than two thirds of their daily time indoors. Hence, maintaining a healthy indoor environment is indispensable for the prevention of building related illness. In Japan, guidelines for indoor air quality have been established for 13 volatile/semi-volatile organic compounds (VOCs/SVOCs). These guidelines are now under revision by the Committee on Sick House Syndrome: Indoor Air Pollution. In order to gain information on the current indoor air pollutants and their levels, we carried out a nation-wide survey of VOCs and aldehydes in indoor residential air during 2012-2013. In this review, I concisely summarized the current indoor air quality of Japan.

  16. Indoor Air Quality in Schools

    EPA Pesticide Factsheets

    This web site will educate the public about indoor environmental issues specific to educational facilities and the importance of developing and sustaining comprehensive indoor air quality management programs.

  17. ASSESSMENT OF THE INDOOR ENVIRONMENT AND IMPLICATIONS FOR HEALTH IN ROMA VILLAGES IN SLOVAKIA AND ROMANIA

    PubMed Central

    Majdan, Marek; Coman, Alexandru; Gallová, Eva; Ďuricová, Janka; Kállayová, Daniela; Kvaková, Mária; Bošák, Ľuboš

    2013-01-01

    SUMMARY Objectives The objective of this paper is to provide information on indoor air quality and on the quality of the broader indoor environment of the houses in Roma villages in Slovakia and Romania and to discuss possible implications for health. Methods Indoor air was sampled in 11 houses in a Romanian Roma village and in 19 houses in a Slovakian Roma village. Levels of Carbon Monoxide (CO), Carbon Dioxide (CO2), total particulate matter (PM), temperature and humidity were measured. A questionnaire and a checklist were used to obtain additional information on the indoor environment and behavioural factors. We have sampled the same houses in winter and in summer. Results Levels of CO and CO2 were higher in winter in both countries as compared to summer. The limit value of 10 mg/m3 CO was exceeded in a few cases in both countries. In general, levels of CO, CO2 and PM were higher in Romania. Further environmental and behavioural hazards such as indoor smoking, pets inside or lack of ventilation were found. The reported self-perceived quality of the indoor environment was poor in many aspects. Conclusions Our findings of CO, CO2 and PM levels suggest that indoor air pollution in Roma settlements has the potential to be a health threat. The fact that the inhabitants spend a relatively long time inside the houses and that a number of additional environmental and behavioural hazards were identified by our study emphasizes the importance of the indoor air quality for health and thus priority attention should be paid to these issues by health authorities and researchers. Further research is essential and study designs must consider cultural background and specific characteristics of the community, especially in order to obtain valid data on health outcomes. PMID:23285520

  18. Isolation of Toxigenic Nocardiopsis Strains from Indoor Environments and Description of Two New Nocardiopsis Species, N. exhalans sp. nov. and N. umidischolae sp. nov.

    PubMed Central

    Peltola, Joanna S. P.; Andersson, Maria A.; Kämpfer, Peter; Auling, Georg; Kroppenstedt, Reiner M.; Busse, Hans-Jürgen; Salkinoja-Salonen, Mirja S.; Rainey, Frederick A.

    2001-01-01

    Nocardiopsis strains were isolated from water-damaged indoor environments. Two strains (N. alba subsp. alba 704a and a strain representing a novel species, ES10.1) as well as strains of N. prasina, N. lucentensis, and N. tropica produced methanol-soluble toxins that paralyzed the motility of boar spermatozoa at <30 μg of crude extract (dry weight) ml−1. N. prasina, N. lucentensis, N. tropica, and strain ES10.1 caused cessation of motility by dissipating the mitochondrial membrane potential, Δψ, of the boar spermatozoa. Indoor strain 704a produced a substance that destroyed cell membrane barrier function and depleted the sperm cells of ATP. Indoor strain 64/93 was antagonistic towards Corynebacterium renale. Two indoor Nocardiopsis strains were xerotolerant, and all five utilized a wide range of substrates. This combined with the production of toxic substances suggests good survival and potential hazard to human health in water-damaged indoor environments. Two new species, Nocardiopsis exhalans sp. nov. (ES10.1T) and Nocardiopsis umidischolae sp. nov. (66/93T), are proposed based on morphology, chemotaxonomic and physiological characters, phylogenetic analysis, and DNA-DNA reassociations. PMID:11526036

  19. Indoor-Breeding of Aedes albopictus in Northern Peninsular Malaysia and Its Potential Epidemiological Implications

    PubMed Central

    Dieng, Hamady; Saifur, Rahman G. M.; Hassan, Ahmad Abu; Salmah, M. R. Che; Boots, Michael; Satho, Tomomitsu; Jaal, Zairi; AbuBakar, Sazaly

    2010-01-01

    Background The mosquito Ae. albopictus is usually adapted to the peri-domestic environment and typically breeds outdoors. However, we observed its larvae in most containers within homes in northern peninsular Malaysia. To anticipate the epidemiological implications of this indoor-breeding, we assessed some fitness traits affecting vectorial capacity during colonization process. Specifically, we examined whether Ae. albopictus exhibits increased survival, gonotrophic activity and fecundity due to the potential increase in blood feeding opportunities. Methodology/Principal Findings In a series of experiments involving outdoors and indoors breeding populations, we found that Ae. albopictus lives longer in the indoor environment. We also observed increased nighttime biting activity and lifetime fecundity in indoor/domestic adapted females, although they were similar to recently colonized females in body size. Conclusion/Significance Taken together these data suggest that accommodation of Ae. albopictus to indoor/domestic environment may increase its lifespan, blood feeding success, nuisance and thus vectorial capacity (both in terms of increased vector-host contacts and vector population density). These changes in the breeding behavior of Ae. albopictus, a potential vector of several human pathogens including dengue viruses, require special attention. PMID:20668543

  20. Correspondence between Children's Indoor and Outdoor Play in Japanese Preschool Daily Life

    ERIC Educational Resources Information Center

    Hirose, Toshiya; Koda, Naoko; Minami, Tetsuhiro

    2012-01-01

    This study examined the correspondence between children's indoor and outdoor play in a preschool environment to investigate whether the children maintained a tendency to engage in a particular type of play irrespective of the environment, or whether they changed the type of play according to the environment. Play behaviours of 18 three-year-old…

  1. A first overview of textile fibers, including microplastics, in indoor and outdoor environments.

    PubMed

    Dris, Rachid; Gasperi, Johnny; Mirande, Cécile; Mandin, Corinne; Guerrouache, Mohamed; Langlois, Valérie; Tassin, Bruno

    2017-02-01

    Studies about microplastics in various environments highlighted the ubiquity of anthropogenic fibers. As a follow-up of a recent study that emphasized the presence of man-made fibers in atmospheric fallout, this study is the first one to investigate fibers in indoor and outdoor air. Three different indoor sites were considered: two private apartments and one office. In parallel, the outdoor air was sampled in one site. The deposition rate of the fibers and their concentration in settled dust collected from vacuum cleaner bags were also estimated. Overall, indoor concentrations ranged between 1.0 and 60.0 fibers/m 3 . Outdoor concentrations are significantly lower as they range between 0.3 and 1.5 fibers/m 3 . The deposition rate of the fibers in indoor environments is between 1586 and 11,130 fibers/day/m 2 leading to an accumulation of fibers in settled dust (190-670 fibers/mg). Regarding fiber type, 67% of the analyzed fibers in indoor environments are made of natural material, primarily cellulosic, while the remaining 33% fibers contain petrochemicals with polypropylene being predominant. Such fibers are observed in marine and continental studies dealing with microplastics. The observed fibers are supposedly too large to be inhaled but the exposure may occur through dust ingestion, particularly for young children. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Diagrams Showing Actions for Reducing Exposures to Polychlorinated Biphenyls (PCBs) in Indoor Building Environments

    EPA Pesticide Factsheets

    This diagram compliments the document, PCBs in Building Materials: Q's & A's, on how exposure to PCBs can be assessed and reduced in school buildings. It describes actions for reducing exposures to PCBs in indoor school building environments.

  3. Feasibility analysis on the building environment of college dormitories in Baoding

    NASA Astrophysics Data System (ADS)

    Wang, Xinyi

    2018-06-01

    The quality of indoor air greatly affects people's health. As a place where college students live for a long time, the architectural environment is closely related to people's lives. In this paper, two cases of dormitory of the North China Electric Power University in Baoding are selected as the subject investigated. The environmental test and questionnaire method were used to study. The test indexes mainly include temperature, relative humidity and wind speeds. We obtain the basic situation of indoor thermal humidity environment, light environment and air velocity. Based on a series of tests, combined with subjective comfort and comprehensive evaluation, we analyzed the thermal comfort of indoor buildings, and put forward measures to further improve the building environment of College Dormitories under the principle of high efficiency and energy saving.

  4. Indoor airborne bacterial communities are influenced by ventilation, occupancy, and outdoor air source.

    PubMed

    Meadow, J F; Altrichter, A E; Kembel, S W; Kline, J; Mhuireach, G; Moriyama, M; Northcutt, D; O'Connor, T K; Womack, A M; Brown, G Z; Green, J L; Bohannan, B J M

    2014-02-01

    Architects and engineers are beginning to consider a new dimension of indoor air: the structure and composition of airborne microbial communities. A first step in this emerging field is to understand the forces that shape the diversity of bioaerosols across space and time within the built environment. In an effort to elucidate the relative influences of three likely drivers of indoor bioaerosol diversity - variation in outdoor bioaerosols, ventilation strategy, and occupancy load - we conducted an intensive temporal study of indoor airborne bacterial communities in a high-traffic university building with a hybrid HVAC (mechanically and naturally ventilated) system. Indoor air communities closely tracked outdoor air communities, but human-associated bacterial genera were more than twice as abundant in indoor air compared with outdoor air. Ventilation had a demonstrated effect on indoor airborne bacterial community composition; changes in outdoor air communities were detected inside following a time lag associated with differing ventilation strategies relevant to modern building design. Our results indicate that both occupancy patterns and ventilation strategies are important for understanding airborne microbial community dynamics in the built environment. © 2013 The Authors. Indoor Air published by John Wiley & Sons Ltd.

  5. Assessment of the unattached fraction of indoor radon progeny and its contribution to dose: a pilot study in China.

    PubMed

    Guo, Qiuju; Zhang, Lei; Guo, Lu

    2012-12-01

    The unattached fraction of radon progeny (f(p)) is one of the most important factors for accurate evaluation of the effective dose from a unit of radon exposure, and it may vary greatly in different environments. For precise evaluation of the indoor radon exposure dose and the influence of unattached radon progeny, a pilot survey of f(p) in different environments was carried out in China with a portable and integrating monitor. The dose conversion factors for radon progeny are calculated with LUDEP(®) code, and the dose contributions from the unattached and the attached radon progenies were simultaneously evaluated based on the results of field measurements. The results show that even though the concentrations of radon progeny vary significantly among different indoor environments, the variations of f(p) seem relatively small (9.3-16.9%). The dose contribution from unattached radon progeny is generally larger (30.2-46.2%) in an indoor environment.

  6. Indoor and Outdoor Surface-Growing Fungi Contamination at Higher Institutional Buildings in a Malaysian University

    NASA Astrophysics Data System (ADS)

    Er, C. M.; Sunar, N. M.; Leman, A. M.; Khalid, A.; Ali, R.; Zaidi, E.; Azhar, A. T. S.

    2018-04-01

    Surface-growing indoor and outdoor fungi were assessed using swabbing method to investigate the indoor contamination. The painted wall surface samples were collected from two institutional buildings (B1 and B2) of a university in southern Peninsular Malaysia; indoors and outdoors. The mould concentrations varied widely between indoor and outdoor surface samples of both buildings. The total indoor surface-growing mould concentration (8776.49 CFU/cm2) is significantly higher (p<0.05) than the total concentration of outdoor surface growing mould (209.91 CFU/cm2). Respectively, the mean concentration of indoor surface-growing mould (18920.13 CFU/cm2 for B1 and 3704.67 CFU/cm2 for B2) is significantly higher than their outdoor counterparts (99.95 CFU/cm2 for b1 and for 319.86 CFU/cm2 b2) at these buildings. Besides, various air quality parameters (relative humidity, temperature and air velocity) were also measured indoors and outdoors during the study and violation of the guideline provided by ICOP-IAQ 2010 were proven in indoor environment in both buildings. The results of this assessment showed that the indoor environments of both institutional buildings were contaminated by the surface-growing mould. It also suggested the faulty designs and/or usages of building material in these institutional buildings contributed toward the contamination. An innovative solution is needed to correct the problems.

  7. An Office Building Occupants Guide to Indoor Air Quality - Printable Version

    EPA Pesticide Factsheets

    This guide is intended to help people who work in office buildings learn about the factors that contribute to indoor air quality and comfort problems and the roles of building managers and occupants in maintaining a good indoor environment.

  8. THE INTERACTION OF VAPOUR PHASE ORGANIC COMPOUNDS WITH INDOOR SINKS

    EPA Science Inventory

    The interaction of indoor air pollutants with interior surfaces (i.e., sinks) is a well known, but poorly understood, phenomenon. Studies have shown that re-emissions of adsorbed organic vapours can contribute to elevated concentrations of organics in indoor environments. Researc...

  9. Received Signal Strength Database Interpolation by Kriging for a Wi-Fi Indoor Positioning System

    PubMed Central

    Jan, Shau-Shiun; Yeh, Shuo-Ju; Liu, Ya-Wen

    2015-01-01

    The main approach for a Wi-Fi indoor positioning system is based on the received signal strength (RSS) measurements, and the fingerprinting method is utilized to determine the user position by matching the RSS values with the pre-surveyed RSS database. To build a RSS fingerprint database is essential for an RSS based indoor positioning system, and building such a RSS fingerprint database requires lots of time and effort. As the range of the indoor environment becomes larger, labor is increased. To provide better indoor positioning services and to reduce the labor required for the establishment of the positioning system at the same time, an indoor positioning system with an appropriate spatial interpolation method is needed. In addition, the advantage of the RSS approach is that the signal strength decays as the transmission distance increases, and this signal propagation characteristic is applied to an interpolated database with the Kriging algorithm in this paper. Using the distribution of reference points (RPs) at measured points, the signal propagation model of the Wi-Fi access point (AP) in the building can be built and expressed as a function. The function, as the spatial structure of the environment, can create the RSS database quickly in different indoor environments. Thus, in this paper, a Wi-Fi indoor positioning system based on the Kriging fingerprinting method is developed. As shown in the experiment results, with a 72.2% probability, the error of the extended RSS database with Kriging is less than 3 dBm compared to the surveyed RSS database. Importantly, the positioning error of the developed Wi-Fi indoor positioning system with Kriging is reduced by 17.9% in average than that without Kriging. PMID:26343673

  10. Received Signal Strength Database Interpolation by Kriging for a Wi-Fi Indoor Positioning System.

    PubMed

    Jan, Shau-Shiun; Yeh, Shuo-Ju; Liu, Ya-Wen

    2015-08-28

    The main approach for a Wi-Fi indoor positioning system is based on the received signal strength (RSS) measurements, and the fingerprinting method is utilized to determine the user position by matching the RSS values with the pre-surveyed RSS database. To build a RSS fingerprint database is essential for an RSS based indoor positioning system, and building such a RSS fingerprint database requires lots of time and effort. As the range of the indoor environment becomes larger, labor is increased. To provide better indoor positioning services and to reduce the labor required for the establishment of the positioning system at the same time, an indoor positioning system with an appropriate spatial interpolation method is needed. In addition, the advantage of the RSS approach is that the signal strength decays as the transmission distance increases, and this signal propagation characteristic is applied to an interpolated database with the Kriging algorithm in this paper. Using the distribution of reference points (RPs) at measured points, the signal propagation model of the Wi-Fi access point (AP) in the building can be built and expressed as a function. The function, as the spatial structure of the environment, can create the RSS database quickly in different indoor environments. Thus, in this paper, a Wi-Fi indoor positioning system based on the Kriging fingerprinting method is developed. As shown in the experiment results, with a 72.2% probability, the error of the extended RSS database with Kriging is less than 3 dBm compared to the surveyed RSS database. Importantly, the positioning error of the developed Wi-Fi indoor positioning system with Kriging is reduced by 17.9% in average than that without Kriging.

  11. Assessment of indoor PM2.5 in different residential environments

    NASA Astrophysics Data System (ADS)

    Yassin, Mohamed F.; AlThaqeb, Bothaina E. Y.; Al-Mutiri, Eman A. E.

    2012-09-01

    The indoor air quality (IAQ) as assessed by PM2.5 (particulate matter with an aerodynamic diameter of less than 2.5 μm) was measured at indoor settings in various residential houses which were located in different local environments across Kuwait. The indoor house settings included kitchen, living room, and bedrooms. Samples were collected from houses over 24 h. PM2.5 was estimated using a Dust-Trak personal sampler. Results were analyzed and compared with the US Environmental Protection Agencies (EPA) and World Health Organization (WHO) standards and guidelines. The results demonstrated that kitchens have the highest PM2.5 concentration probably due to cooking activities; the bedroom has the lowest PM2.5 concentration. The study shows that Kuwait indoor residential pollution is among the worst in comparison with other countries.

  12. Ozone and limonene in indoor air: a source of submicron particle exposure.

    PubMed Central

    Wainman, T; Zhang, J; Weschler, C J; Lioy, P J

    2000-01-01

    Little information currently exists regarding the occurrence of secondary organic aerosol formation in indoor air. Smog chamber studies have demonstrated that high aerosol yields result from the reaction of ozone with terpenes, both of which commonly occur in indoor air. However, smog chambers are typically static systems, whereas indoor environments are dynamic. We conducted a series of experiments to investigate the potential for secondary aerosol in indoor air as a result of the reaction of ozone with d-limonene, a compound commonly used in air fresheners. A dynamic chamber design was used in which a smaller chamber was nested inside a larger one, with air exchange occurring between the two. The inner chamber was used to represent a model indoor environment and was operated at an air exchange rate below 1 exchange/hr, while the outer chamber was operated at a high air exchange rate of approximately 45 exchanges/hr. Limonene was introduced into the inner chamber either by the evaporation of reagent-grade d-limonene or by inserting a lemon-scented, solid air freshener. A series of ozone injections were made into the inner chamber during the course of each experiment, and an optical particle counter was used to measure the particle concentration. Measurable particle formation and growth occurred almost exclusively in the 0.1-0.2 microm and 0.2-0.3 microm size fractions in all of the experiments. Particle formation in the 0.1-0.2 microm size range occurred as soon as ozone was introduced, but the formation of particles in the 0.2-0.3 microm size range did not occur until at least the second ozone injection occurred. The results of this study show a clear potential for significant particle concentrations to be produced in indoor environments as a result of secondary particle formation via the ozone-limonene reaction. Because people spend the majority of their time indoors, secondary particles formed in indoor environments may make a significant contribution to overall particle exposure. This study provides data for assessing the impact of outdoor ozone on indoor particles. This is important to determine the efficacy of the mass-based particulate matter standards in protecting public health because the indoor secondary particles can vary coincidently with the variations of outdoor fine particles in summer. PMID:11133393

  13. Ozone and limonene in indoor air: a source of submicron particle exposure.

    PubMed

    Wainman, T; Zhang, J; Weschler, C J; Lioy, P J

    2000-12-01

    Little information currently exists regarding the occurrence of secondary organic aerosol formation in indoor air. Smog chamber studies have demonstrated that high aerosol yields result from the reaction of ozone with terpenes, both of which commonly occur in indoor air. However, smog chambers are typically static systems, whereas indoor environments are dynamic. We conducted a series of experiments to investigate the potential for secondary aerosol in indoor air as a result of the reaction of ozone with d-limonene, a compound commonly used in air fresheners. A dynamic chamber design was used in which a smaller chamber was nested inside a larger one, with air exchange occurring between the two. The inner chamber was used to represent a model indoor environment and was operated at an air exchange rate below 1 exchange/hr, while the outer chamber was operated at a high air exchange rate of approximately 45 exchanges/hr. Limonene was introduced into the inner chamber either by the evaporation of reagent-grade d-limonene or by inserting a lemon-scented, solid air freshener. A series of ozone injections were made into the inner chamber during the course of each experiment, and an optical particle counter was used to measure the particle concentration. Measurable particle formation and growth occurred almost exclusively in the 0.1-0.2 microm and 0.2-0.3 microm size fractions in all of the experiments. Particle formation in the 0.1-0.2 microm size range occurred as soon as ozone was introduced, but the formation of particles in the 0.2-0.3 microm size range did not occur until at least the second ozone injection occurred. The results of this study show a clear potential for significant particle concentrations to be produced in indoor environments as a result of secondary particle formation via the ozone-limonene reaction. Because people spend the majority of their time indoors, secondary particles formed in indoor environments may make a significant contribution to overall particle exposure. This study provides data for assessing the impact of outdoor ozone on indoor particles. This is important to determine the efficacy of the mass-based particulate matter standards in protecting public health because the indoor secondary particles can vary coincidently with the variations of outdoor fine particles in summer.

  14. Report: EPA’s Radiation and Indoor Environments National Laboratory Should Improve Its Computer Room Security Controls

    EPA Pesticide Factsheets

    Report #12-P-0847, September 21, 2012.Our review of the security posture and in-place environmental controls of EPA’s Radiation and Indoor Environments National Laboratory computer room disclosed an array of security and environmental control deficiencies.

  15. Determination of fluorotelomer alcohols in selected consumer products and preliminary investigation of their fate in the indoor environment

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA) has established an ongoing effort to identify the major perfluorocarboxylic acid (PFCA) sources in nonoccupational indoor environments and characterize their transport and fate. This study determined the concentrations of perfluorote...

  16. Bois Forte Indoor Air Quality Program

    EPA Pesticide Factsheets

    The Bois Forte Indoor Air Quality Program acted swiftly and aggressively to tackle mold and moisture problems in its community members’ homes after several residents became ill as a result of environmental exposures.

  17. Influence of the level of description of the indoor environment on the characteristic parameters of a MIMO channel

    NASA Astrophysics Data System (ADS)

    Pereira, Carlos; Chartois, Yannick; Pousset, Yannis; Vauzelle, Rodolphe

    2006-09-01

    Modelling of the environment is an important factor in electromagnetic wave propagation simulation, performed by a 3D ray-tracing method. The aim of this work is to study the effect of indoor environment modelling accuracy on MIMO (Multiple Input Multiple Output) channel characterisation. The first of the two environments investigated is the hall of our building, while the second one is a more confined environment and represents the floor of our laboratory. For these two indoor environments, three description levels are proposed in order to establish geometrical and electrical modelling impact on MIMO channel characterisation. Results are obtained by analysing the capacity and variation in correlation in relation to the polarisation, the presence of LOS (Line of sight) or NLOS configurations, the spacing between antennae and the number of transmitter and receiver antennae. To cite this article: C. Pereira et al., C. R. Physique 7 (2006).

  18. Occupant perception of indoor air and comfort in four hospitality environments.

    PubMed

    Moschandreas, D J; Chu, P

    2002-01-01

    This article reports on a survey of customer and staff perceptions of indoor air quality at two restaurants, a billiard hall, and a casino. The survey was conducted at each environment for 8 days: 2 weekend days on 2 consecutive weekends and 4 weekdays. Before and during the survey, each hospitality environment satisfied ventilation requirements set in ASHRAE Standard 62-1999, Ventilation for Acceptable Indoor Air. An objective of this study was to test the hypothesis: If a hospitality environment satisfies ASHRAE ventilation requirements, then the indoor air is acceptable, that is, fewer than 20% of the exposed occupants perceive the environment as unacceptable. A second objective was to develop a multiple regression model that predicts the dependent variable, the environment is acceptable, as a function of a number of independent perception variables. Occupant perception of environmental, comfort, and physical variables was measured using a questionnaire. This instrument was designed to be efficient and unobtrusive; subjects could complete it within 3 min. Significant differences of occupant environment perception were identified among customers and staff. The dependent variable, the environment is acceptable, is affected by temperature, occupant density, and occupant smoking status, odor perception, health conditions, sensitivity to chemicals, and enjoyment of activities. Depending on the hospitality environment, variation of independent variables explains as much as 77% of the variation of the dependent variable.

  19. Variation of the unattached fraction of radon progeny and its contribution to radon exposure.

    PubMed

    Guo, Lu; Zhang, Lei; Guo, Qiuju

    2016-06-01

    The unattached fraction of radon progeny is one of the most important factors for radon exposure evaluation through the dosimetric approach. To better understand its level and variation in the real environment, a series of field measurements were carried out indoors and outdoors, and radon equilibrium equivalent concentration was also measured. The dose contribution of unattached radon progeny was evaluated in addition. The results show that no clear variation trend of the unattached fraction of radon progeny is observed in an indoor or outdoor environment. The average unattached fraction of radon progeny for the indoors and outdoors are (8.7  ±  1.6)% and (9.7  ±  2.1)%, respectively. The dose contribution of unattached radon progeny to total radon exposure is some 38.8% in an indoor environment, suggesting the importance of the evaluation on unattached radon progeny.

  20. Mobile robot self-localization system using single webcam distance measurement technology in indoor environments.

    PubMed

    Li, I-Hsum; Chen, Ming-Chang; Wang, Wei-Yen; Su, Shun-Feng; Lai, To-Wen

    2014-01-27

    A single-webcam distance measurement technique for indoor robot localization is proposed in this paper. The proposed localization technique uses webcams that are available in an existing surveillance environment. The developed image-based distance measurement system (IBDMS) and parallel lines distance measurement system (PLDMS) have two merits. Firstly, only one webcam is required for estimating the distance. Secondly, the set-up of IBDMS and PLDMS is easy, which only one known-dimension rectangle pattern is needed, i.e., a ground tile. Some common and simple image processing techniques, i.e., background subtraction are used to capture the robot in real time. Thus, for the purposes of indoor robot localization, the proposed method does not need to use expensive high-resolution webcams and complicated pattern recognition methods but just few simple estimating formulas. From the experimental results, the proposed robot localization method is reliable and effective in an indoor environment.

  1. Coupling indoor airflow, HVAC, control and building envelope heat transfer in the Modelica Buildings library

    DOE PAGES

    Zuo, Wangda; Wetter, Michael; Tian, Wei; ...

    2015-07-13

    Here, this paper describes a coupled dynamic simulation of an indoor environment with heating, ventilation, and air conditioning (HVAC) systems, controls and building envelope heat transfer. The coupled simulation can be used for the design and control of ventilation systems with stratified air distributions. Those systems are commonly used to reduce building energy consumption while improving the indoor environment quality. The indoor environment was simulated using the fast fluid dynamics (FFD) simulation programme. The building fabric heat transfer, HVAC and control system were modelled using the Modelica Buildings library. After presenting the concept, the mathematical algorithm and the implementation ofmore » the coupled simulation were introduced. The coupled FFD–Modelica simulation was then evaluated using three examples of room ventilation with complex flow distributions with and without feedback control. Lastly, further research and development needs were also discussed.« less

  2. Mobile Robot Self-Localization System Using Single Webcam Distance Measurement Technology in Indoor Environments

    PubMed Central

    Li, I-Hsum; Chen, Ming-Chang; Wang, Wei-Yen; Su, Shun-Feng; Lai, To-Wen

    2014-01-01

    A single-webcam distance measurement technique for indoor robot localization is proposed in this paper. The proposed localization technique uses webcams that are available in an existing surveillance environment. The developed image-based distance measurement system (IBDMS) and parallel lines distance measurement system (PLDMS) have two merits. Firstly, only one webcam is required for estimating the distance. Secondly, the set-up of IBDMS and PLDMS is easy, which only one known-dimension rectangle pattern is needed, i.e., a ground tile. Some common and simple image processing techniques, i.e., background subtraction are used to capture the robot in real time. Thus, for the purposes of indoor robot localization, the proposed method does not need to use expensive high-resolution webcams and complicated pattern recognition methods but just few simple estimating formulas. From the experimental results, the proposed robot localization method is reliable and effective in an indoor environment. PMID:24473282

  3. Coupling indoor airflow, HVAC, control and building envelope heat transfer in the Modelica Buildings library

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zuo, Wangda; Wetter, Michael; Tian, Wei

    Here, this paper describes a coupled dynamic simulation of an indoor environment with heating, ventilation, and air conditioning (HVAC) systems, controls and building envelope heat transfer. The coupled simulation can be used for the design and control of ventilation systems with stratified air distributions. Those systems are commonly used to reduce building energy consumption while improving the indoor environment quality. The indoor environment was simulated using the fast fluid dynamics (FFD) simulation programme. The building fabric heat transfer, HVAC and control system were modelled using the Modelica Buildings library. After presenting the concept, the mathematical algorithm and the implementation ofmore » the coupled simulation were introduced. The coupled FFD–Modelica simulation was then evaluated using three examples of room ventilation with complex flow distributions with and without feedback control. Lastly, further research and development needs were also discussed.« less

  4. Evaluation and guidelines for using polyurethane foam (PUF) passive air samplers in double-dome chambers to assess semi-volatile organic compounds (SVOCs) in non-industrial indoor environments.

    PubMed

    Bohlin, Pernilla; Audy, Ondřej; Škrdlíková, Lenka; Kukučka, Petr; Vojta, Šimon; Přibylová, Petra; Prokeš, Roman; Čupr, Pavel; Klánová, Jana

    2014-11-01

    Indoor air pollution has been recognized as an important risk factor for human health, especially in areas where people tend to spend most of their time indoors. Many semi-volatile organic compounds (SVOCs) have primarily indoor sources and are present in orders of magnitude higher concentrations indoors than outdoors. Despite this, awareness of SVOCs in indoor air and assessment of the link between indoor concentrations and human health have lagged behind those of outdoor air. This is partially related to challenges associated with indoor sampling of SVOCs. Passive air samplers (PASs), which are widely accepted in established outdoor air monitoring networks, have been used to fill the knowledge gaps on indoor SVOCs distribution. However, their applicability for indoor environments and the assessment of human health risks lack sufficient experimental data. To address this issue, we performed an indoor calibration study of polyurethane foam (PUF) PAS deployed in a double-dome chamber, covering both legacy and new SVOC classes. PUF-PAS and a continuous low-volume active air sampler (AAS) were co-deployed for a calibration period of twelve weeks. Based on the results from this evaluation, PUF-PAS in a double-bowl chamber is recommended for indoor sampling and health risk assessment of gas phase SVOCs, including novel brominated flame retardants (nBFR) providing sufficient exposure time is applied. Data for particle associated SVOCs suffered from significant uncertainties caused by low level of detection and low precision in this study. A more open chamber design for indoor studies may allow for higher sampling rates (RS) and better performance for the particle associated SVOCs.

  5. Indoor airborne particle sources and outdoor haze days effect in urban office areas in Guangzhou.

    PubMed

    Zhang, Manwen; Zhang, Sukun; Feng, Guixian; Su, Hui; Zhu, Fengzhi; Ren, Mingzhong; Cai, Zongwei

    2017-04-01

    To identify the sources of PM 2.5 pollutants in work environments and determine whether the air quality inside an office was affected by a change in outdoor pollution status, concurrent indoor and outdoor measurements of PM 2.5 were conducted at five different office spaces in the urban center of Guangzhou on low pollution days (non-episode days, NEDs), and high pollution days (haze episode days, EDs). Indoor-outdoor relationships between the PM 2.5 mass and its chemical constituents, which included water-soluble ions, carbonaceous species, and metal elements, were investigated. A principle component analysis (PCA) was performed to further confirm the relationship between the indoor and outdoor PM 2.5 pollution. The results reveal that (1) Printing and ETS (Environmental tobacco smoking) were found to be important office PM 2.5 sources and associated with the enrichment of SO 4 2- , OC, EC and some toxic metals indoors; (2) On EDs, serious outdoor pollution and higher air exchange rate greatly affected all studied office environments, masking the original differences of the indoor characteristics (3) Fresh air system could efficiently filter out most of the outside pollutants on both NEDs and EDs. Overall, the results of our study suggest that improper human behavior is associated with the day-to-day generation of indoor PM 2.5 levels and sporadic outdoor pollution events can lead to poor indoor air quality in urban office environments. Moreover, fresh air system has been experimentally proved with data as an effective way to improve the air quality in office. Copyright © 2016. Published by Elsevier Inc.

  6. EVALUATION OF UV IRRADIATION CONTROL MEASURES FOR REDUCING MICROBIAL CONTAMINATION (BIO-TERRORISM SAFETY)

    EPA Science Inventory

    Exposures from indoor environments are a major issue for evaluating total long-term personal exposures to the fine fraction (
    Biocontaminants such as some mold spores or pollen grains, because of their size and mass, settle rapidly within the indoor environment. Over time the...

  7. VOLATILE ORGANIC COMPOUND EMISSIONS FROM LATEX PAINT - PART 1. CHAMBER EXPERIMENTS AND SOURCE MODEL DEVELOPMENT

    EPA Science Inventory

    Latex paints are widely used in residential and commercial indoor environments. The surface areas covered by the paints in these environments are relatively large. Thus, latex paints have the potential for having a major impact on indoor air quality (IAQ). A study was undertaken ...

  8. A particle image velocimetry validation database in the inoor environment using a breathing thermal manakin in rotational motion

    EPA Science Inventory

    Determination of indoor exposure levels commonly involves assumptions of fully mixed ventilation conditions. In the effort to determine contaminant levels with efficiency, the nodal approach is common in modeling of the indoor environment. To quantify the transport phenomenon or ...

  9. An Evaluation of Antifungal Agents for the Treatment of Fungal Contamination in Indoor Air Environments

    PubMed Central

    Rogawansamy, Senthaamarai; Gaskin, Sharyn; Taylor, Michael; Pisaniello, Dino

    2015-01-01

    Fungal contamination in indoor environments has been associated with adverse health effects for the inhabitants. Remediation of fungal contamination requires removal of the fungi present and modifying the indoor environment to become less favourable to growth.  This may include treatment of indoor environments with an antifungal agent to prevent future growth. However there are limited published data or advice on chemical agents suitable for indoor fungal remediation. The aim of this study was to assess the relative efficacies of five commercially available cleaning agents with published or anecdotal use for indoor fungal remediation. The five agents included two common multi-purpose industrial disinfectants (Cavicide® and Virkon®), 70% ethanol, vinegar (4.0%−4.2% acetic acid), and a plant-derived compound (tea tree (Melaleuca alternifolia) oil) tested in both a liquid and vapour form. Tea tree oil has recently generated interest for its antimicrobial efficacy in clinical settings, but has not been widely employed for fungal remediation. Each antifungal agent was assessed for fungal growth inhibition using a disc diffusion method against a representative species from two common fungal genera, (Aspergillus fumigatus and Penicillium chrysogenum), which were isolated from air samples and are commonly found in indoor air. Tea tree oil demonstrated the greatest inhibitory effect on the growth of both fungi, applied in either a liquid or vapour form. Cavicide® and Virkon® demonstrated similar, although less, growth inhibition of both genera. Vinegar (4.0%–4.2% acetic acid) was found to only inhibit the growth of P. chrysogenum, while 70% ethanol was found to have no inhibitory effect on the growth of either fungi. There was a notable inhibition in sporulation, distinct from growth inhibition after exposure to tea tree oil, Virkon®, Cavicide® and vinegar. Results demonstrate that common cleaning and antifungal agents differ in their capacity to inhibit the growth of fungal genera found in the indoor air environment. The results indicate that tea tree oil was the most effective antifungal agent tested, and may have industrial application for the remediation of fungal contamination in residential and occupational buildings. PMID:26042369

  10. An evaluation of antifungal agents for the treatment of fungal contamination in indoor air environments.

    PubMed

    Rogawansamy, Senthaamarai; Gaskin, Sharyn; Taylor, Michael; Pisaniello, Dino

    2015-06-02

    Fungal contamination in indoor environments has been associated with adverse health effects for the inhabitants. Remediation of fungal contamination requires removal of the fungi present and modifying the indoor environment to become less favourable to growth.  This may include treatment of indoor environments with an antifungal agent to prevent future growth. However there are limited published data or advice on chemical agents suitable for indoor fungal remediation. The aim of this study was to assess the relative efficacies of five commercially available cleaning agents with published or anecdotal use for indoor fungal remediation. The five agents included two common multi-purpose industrial disinfectants (Cavicide® and Virkon®), 70% ethanol, vinegar (4.0%-4.2% acetic acid), and a plant-derived compound (tea tree (Melaleuca alternifolia) oil) tested in both a liquid and vapour form. Tea tree oil has recently generated interest for its antimicrobial efficacy in clinical settings, but has not been widely employed for fungal remediation. Each antifungal agent was assessed for fungal growth inhibition using a disc diffusion method against a representative species from two common fungal genera, (Aspergillus fumigatus and Penicillium chrysogenum), which were isolated from air samples and are commonly found in indoor air. Tea tree oil demonstrated the greatest inhibitory effect on the growth of both fungi, applied in either a liquid or vapour form. Cavicide® and Virkon® demonstrated similar, although less, growth inhibition of both genera. Vinegar (4.0%-4.2% acetic acid) was found to only inhibit the growth of P. chrysogenum, while 70% ethanol was found to have no inhibitory effect on the growth of either fungi. There was a notable inhibition in sporulation, distinct from growth inhibition after exposure to tea tree oil, Virkon®, Cavicide® and vinegar. Results demonstrate that common cleaning and antifungal agents differ in their capacity to inhibit the growth of fungal genera found in the indoor air environment. The results indicate that tea tree oil was the most effective antifungal agent tested, and may have industrial application for the remediation of fungal contamination in residential and occupational buildings.

  11. RISK ASSESSMENT/RISK MANAGEMENT FOR INDOOR MOLD

    EPA Science Inventory

    In 1998, a team of eight EPA researchers from NERL, NHEERL, NRMRL and NCEA organized to examine the role of indoor molds/fungi in children's health. The make-up of the indoor environment is critical to the health of children in general and has a particularly important influence ...

  12. INDOOR/OUTDOOR PARTICLE SIZE DISTRIBUTIONS MEASURED IN SELECT HOMES IN THE RALEIGH-DURHAM-CHAPEL HILL, NC AREA

    EPA Science Inventory

    Particle size distributions were measured indoors and outdoors of six residences in the Raleigh-Durham-Chapel Hill, NC area to characterize the factors affecting particle concentrations in the indoor environment, including infiltration of outdoor aerosols. Size resolved partic...

  13. Impact of climate change on the domestic indoor environment and associated health risks in the UK.

    PubMed

    Vardoulakis, Sotiris; Dimitroulopoulou, Chrysanthi; Thornes, John; Lai, Ka-Man; Taylor, Jonathon; Myers, Isabella; Heaviside, Clare; Mavrogianni, Anna; Shrubsole, Clive; Chalabi, Zaid; Davies, Michael; Wilkinson, Paul

    2015-12-01

    There is growing evidence that projected climate change has the potential to significantly affect public health. In the UK, much of this impact is likely to arise by amplifying existing risks related to heat exposure, flooding, and chemical and biological contamination in buildings. Identifying the health effects of climate change on the indoor environment, and risks and opportunities related to climate change adaptation and mitigation, can help protect public health. We explored a range of health risks in the domestic indoor environment related to climate change, as well as the potential health benefits and unintended harmful effects of climate change mitigation and adaptation policies in the UK housing sector. We reviewed relevant scientific literature, focusing on housing-related health effects in the UK likely to arise through either direct or indirect mechanisms of climate change or mitigation and adaptation measures in the built environment. We considered the following categories of effect: (i) indoor temperatures, (ii) indoor air quality, (iii) indoor allergens and infections, and (iv) flood damage and water contamination. Climate change may exacerbate health risks and inequalities across these categories and in a variety of ways, if adequate adaptation measures are not taken. Certain changes to the indoor environment can affect indoor air quality or promote the growth and propagation of pathogenic organisms. Measures aimed at reducing greenhouse gas emissions have the potential for ancillary public health benefits including reductions in health burdens related heat and cold, indoor exposure to air pollution derived from outdoor sources, and mould growth. However, increasing airtightness of dwellings in pursuit of energy efficiency could also have negative effects by increasing concentrations of pollutants (such as PM2.5, CO and radon) derived from indoor or ground sources, and biological contamination. These effects can largely be ameliorated by mechanical ventilation with heat recovery (MVHR) and air filtration, where such solution is feasible and when the system is properly installed, operated and maintained. Groups at high risk of these adverse health effects include the elderly (especially those living on their own), individuals with pre-existing illnesses, people living in overcrowded accommodation, and the socioeconomically deprived. A better understanding of how current and emerging building infrastructure design, construction, and materials may affect health in the context of climate change and mitigation and adaptation measures is needed in the UK and other high income countries. Long-term, energy efficient building design interventions, ensuring adequate ventilation, need to be promoted. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  14. Eligibility of Indoor Plumbing Under Alaska Sanitation Infrastructure Grant Program

    EPA Pesticide Factsheets

    Memorandum response to questions that relate to whether indoor plumbing of homes, as part of a wastewater construction project, is an eligible cost item under the EPA Alaska Sanitation Infrastructure Grant Program.

  15. SET: a pupil detection method using sinusoidal approximation

    PubMed Central

    Javadi, Amir-Homayoun; Hakimi, Zahra; Barati, Morteza; Walsh, Vincent; Tcheang, Lili

    2015-01-01

    Mobile eye-tracking in external environments remains challenging, despite recent advances in eye-tracking software and hardware engineering. Many current methods fail to deal with the vast range of outdoor lighting conditions and the speed at which these can change. This confines experiments to artificial environments where conditions must be tightly controlled. Additionally, the emergence of low-cost eye tracking devices calls for the development of analysis tools that enable non-technical researchers to process the output of their images. We have developed a fast and accurate method (known as “SET”) that is suitable even for natural environments with uncontrolled, dynamic and even extreme lighting conditions. We compared the performance of SET with that of two open-source alternatives by processing two collections of eye images: images of natural outdoor scenes with extreme lighting variations (“Natural”); and images of less challenging indoor scenes (“CASIA-Iris-Thousand”). We show that SET excelled in outdoor conditions and was faster, without significant loss of accuracy, indoors. SET offers a low cost eye-tracking solution, delivering high performance even in challenging outdoor environments. It is offered through an open-source MATLAB toolkit as well as a dynamic-link library (“DLL”), which can be imported into many programming languages including C# and Visual Basic in Windows OS (www.eyegoeyetracker.co.uk). PMID:25914641

  16. Impact of indoor environment on path loss in body area networks.

    PubMed

    Hausman, Sławomir; Januszkiewicz, Łukasz

    2014-10-20

    In this paper the influence of an example indoor environment on narrowband radio channel path loss for body area networks operating around 2.4 GHz is investigated using computer simulations and on-site measurements. In contrast to other similar studies, the simulation model included both a numerical human body phantom and its environment-room walls, floor and ceiling. As an example, radio signal attenuation between two different configurations of transceivers with dipole antennas placed in a direct vicinity of a human body (on-body scenario) is analyzed by computer simulations for several types of reflecting environments. In the analyzed case the propagation environments comprised a human body and office room walls. As a reference environment for comparison, free space with only a conducting ground plane, modelling a steel mesh reinforced concrete floor, was chosen. The transmitting and receiving antennas were placed in two on-body configurations chest-back and chest-arm. Path loss vs. frequency simulation results obtained using Finite Difference Time Domain (FDTD) method and a multi-tissue anthropomorphic phantom were compared to results of measurements taken with a vector network analyzer with a human subject located in an average-size empty cuboidal office room. A comparison of path loss values in different environments variants gives some qualitative and quantitative insight into the adequacy of simplified indoor environment model for the indoor body area network channel representation.

  17. The lasting effect of limonene-induced particle formation on air quality in a genuine indoor environment.

    PubMed

    Rösch, Carolin; Wissenbach, Dirk K; von Bergen, Martin; Franck, Ulrich; Wendisch, Manfred; Schlink, Uwe

    2015-09-01

    Atmospheric ozone-terpene reactions, which form secondary organic aerosol (SOA) particles, can affect indoor air quality when outdoor air mixes with indoor air during ventilation. This study, conducted in Leipzig, Germany, focused on limonene-induced particle formation in a genuine indoor environment (24 m(3)). Particle number, limonene and ozone concentrations were monitored during the whole experimental period. After manual ventilation for 30 min, during which indoor ozone levels reached up to 22.7 ppb, limonene was introduced into the room at concentrations of approximately 180 to 250 μg m(-3). We observed strong particle formation and growth within a diameter range of 9 to 50 nm under real-room conditions. Larger particles with diameters above 100 nm were less affected by limonene introduction. The total particle number concentrations (TPNCs) after limonene introduction clearly exceed outdoor values by a factor of 4.5 to 41 reaching maximum concentrations of up to 267,000 particles cm(-3). The formation strength was influenced by background particles, which attenuated the formation of new SOA with increasing concentration, and by ozone levels, an increase of which by 10 ppb will result in a six times higher TPNC. This study emphasizes indoor environments to be preferred locations for particle formation and growth after ventilation events. As a consequence, SOA formation can produce significantly higher amounts of particles than transported by ventilation into the indoor air.

  18. Health Effects of PCBs in Residences and Schools (HESPERUS): PCB – health Cohort Profile

    PubMed Central

    Bräuner, Elvira Vaclavik; Andersen, Zorana Jovanovic; Frederiksen, Marie; Specht, Ina Olmer; Hougaard, Karin Sørig; Ebbehøj, Niels; Bailey, Janice; Giwercman, Aleksander; Steenland, Kyle; Longnecker, Matthew Paul; Bonde, Jens Peter

    2016-01-01

    Polychlorinated-biphenyls (PCBs) were introduced in the late 1920s and used until the 1970s when they were banned in most countries due to evidence of environmental build-up and possible adverse health effects. However they still persist in the environment, indoors and in humans. Indoor air in contaminated buildings may confer airborne exposure markedly above background regional PCB levels. To date, no epidemiological studies have assessed the health effects from exposure to semi-volatile PCBs in the indoor environment. Indoor air PCBs are generally less chlorinated than PCBs that are absorbed via the diet, or via past occupational exposure; therefore their health effects require separate risk assessment. Two separate cohorts of individuals who have either attended schools (n = 66,769; 26% exposed) or lived in apartment buildings (n = 37,185; 19% exposed), where indoor air PCB concentrations have been measured were created. An individual estimate of long-term airborne PCB exposure was assigned based on measurements. The cohorts will be linked to eight different national data sources on mortality, school records, residential history, socioeconomic status, and chronic disease and reproductive outcomes. The linking of indoor air exposures with health outcomes provides a dataset unprecedented worldwide. We describe a project, called HESPERUS (Health Effects of PCBs in Residences and Schools), which will be the first study of the long term health effects of the lower-chlorinated, semi-volatile PCBs in the indoor environment. PMID:27090775

  19. Health Effects of PCBs in Residences and Schools (HESPERUS): PCB - health Cohort Profile.

    PubMed

    Bräuner, Elvira Vaclavik; Andersen, Zorana Jovanovic; Frederiksen, Marie; Specht, Ina Olmer; Hougaard, Karin Sørig; Ebbehøj, Niels; Bailey, Janice; Giwercman, Aleksander; Steenland, Kyle; Longnecker, Matthew Paul; Bonde, Jens Peter

    2016-04-19

    Polychlorinated-biphenyls (PCBs) were introduced in the late 1920s and used until the 1970s when they were banned in most countries due to evidence of environmental build-up and possible adverse health effects. However they still persist in the environment, indoors and in humans. Indoor air in contaminated buildings may confer airborne exposure markedly above background regional PCB levels. To date, no epidemiological studies have assessed the health effects from exposure to semi-volatile PCBs in the indoor environment. Indoor air PCBs are generally less chlorinated than PCBs that are absorbed via the diet, or via past occupational exposure; therefore their health effects require separate risk assessment. Two separate cohorts of individuals who have either attended schools (n = 66,769; 26% exposed) or lived in apartment buildings (n = 37,185; 19% exposed), where indoor air PCB concentrations have been measured were created. An individual estimate of long-term airborne PCB exposure was assigned based on measurements. The cohorts will be linked to eight different national data sources on mortality, school records, residential history, socioeconomic status, and chronic disease and reproductive outcomes. The linking of indoor air exposures with health outcomes provides a dataset unprecedented worldwide. We describe a project, called HESPERUS (Health Effects of PCBs in Residences and Schools), which will be the first study of the long term health effects of the lower-chlorinated, semi-volatile PCBs in the indoor environment.

  20. Airborne particle-bound brominated flame retardants: Levels, size distribution and indoor-outdoor exchange.

    PubMed

    Zhu, Yue-Shan; Yang, Wan-Dong; Li, Xiu-Wen; Ni, Hong-Gang; Zeng, Hui

    2018-02-01

    The quality of indoor environments has a significant impact on public health. Usually, an indoor environment is treated as a static box, in which physicochemical reactions of indoor air contaminants are negligible. This results in conservative estimates for primary indoor air pollutant concentrations, while also ignoring secondary pollutants. Thus, understanding the relationship between indoor and outdoor particles and particle-bound pollutants is of great significance. For this reason, we collected simultaneous indoor and outdoor measurements of the size distribution of airborne brominated flame retardant (BFR) congeners. The time-dependent concentrations of indoor particles and particle-bound BFRs were then estimated with the mass balance model, accounting for the outdoor concentration, indoor source strength, infiltration, penetration, deposition and indoor resuspension. Based on qualitative observation, the size distributions of ΣPBDE and ΣHBCD were characterized by bimodal peaks. According to our results, particle-bound BDE209 and γ-HBCD underwent degradation. Regardless of the surface adsorption capability of particles and the physicochemical properties of the target compounds, the concentration of BFRs in particles of different size fractions seemed to be governed by the particle distribution. Based on our estimations, for airborne particles and particle-bound BFRs, a window-open ventilated room only takes a quarter of the time to reach an equilibrium between the concentration of pollutants inside and outside compared to a closed room. Unfortunately, indoor pollutants and outdoor pollutants always exist simultaneously, which poses a window-open-or-closed dilemma to achieve proper ventilation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Indoor Chemistry: Materials, Ventilation Systems, and Occupant Activities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morrison, G.C.; Corsi, R.L.; Destaillats, H.

    2006-05-01

    Chemical processes taking place in indoor environments can significantly alter the nature and concentrations of pollutants. Exposure to secondary contaminants generated in these reactions needs to be evaluated in association with many aspects of buildings to minimize their impact on occupant health and well-being. Focusing on indoor ozone chemistry, we describe alternatives for improving indoor air quality by controlling chemical changes related to building materials, ventilation systems, and occupant activities.

  2. THE POTENTIAL OF USING EXERCISE IN NATURE AS AN INTERVENTION TO ENHANCE EXERCISE BEHAVIOR: RESULTS FROM A PILOT STUDY.

    PubMed

    Calogiuri, Giovanna; Nordtug, Hildegunn; Weydahl, Andi

    2015-10-01

    According to attention-restoration theory (ART), natural environments can provide restorative experiences. In this pilot study, a mixed-methods approach was used to examine the potential of using exercise in a natural environment to enhance exercise behaviors. The study included an assessment study and an intervention study (overall n = 19). The participants underwent a standardized exercise program including biking and circuit strength training, either indoors or outdoors in nature. Measurements included connectedness to nature, perceived exertion, perceived environmental restorativeness, enjoyment, affect, future exercise intention, and self-reported exercise behavior. The participants also wrote a brief text describing the way in which the environment influenced their feelings while exercising. Quantitative data were analyzed using the Spearman rank correlation and linear mixed-effects modeling. The qualitative information was analyzed thematically. The integrated results indicated that, in accordance with ART, exercising in nature was associated with a greater potential for restoration and affective responses, which in some participants led to enhanced intention to exercise and increased exercise behavior. However, some perceived that the indoor exercise provided a more effective workout. Further studies on larger samples are needed.

  3. Interior shadings for office indoor visual comfort in humid climate region

    NASA Astrophysics Data System (ADS)

    Dinapradipta, Asri; Sudarma, Erwin; Defiana, Ima; Erwindi, Collinthia

    2018-03-01

    As part of the fenestration system, the interior shadings have also a role to control the indoor environment to maintain indoor visual comfort. As the occupants have personal access to control these, their control behavior then, might enhance or even worsen indoor comfort performance. The controlling behavior might not only influence indoor comfort performance but can also indicate the success or failure of interior shading as a control device element. This paper is intended to report control behavior patterns, as represented by the variety of the slats’ openings of two types of interior shading i.e. Venetian and Vertical blinds and to analyze these on the concurrent impacts to indoor office building’s indoor illuminance and luminance distribution. The purpose of this research is to figure out the shading control patterns as well as to examine the effectiveness of these two types of interior shadings to control indoor visual environment. This study is a quantitative research using experimentation on the slats’ opening of two types of shadings at two identical office rooms. The research results suggested that both types of blinds seem unsuitable for gaining proper illumination values at work planes in humid tropics area. However, these shadings demonstrate good performance for luminance distribution except for that of the closed Venetian blinds.

  4. Continuous Space Estimation: Increasing WiFi-Based Indoor Localization Resolution without Increasing the Site-Survey Effort.

    PubMed

    Hernández, Noelia; Ocaña, Manuel; Alonso, Jose M; Kim, Euntai

    2017-01-13

    Although much research has taken place in WiFi indoor localization systems, their accuracy can still be improved. When designing this kind of system, fingerprint-based methods are a common choice. The problem with fingerprint-based methods comes with the need of site surveying the environment, which is effort consuming. In this work, we propose an approach, based on support vector regression, to estimate the received signal strength at non-site-surveyed positions of the environment. Experiments, performed in a real environment, show that the proposed method could be used to improve the resolution of fingerprint-based indoor WiFi localization systems without increasing the site survey effort.

  5. Continuous Space Estimation: Increasing WiFi-Based Indoor Localization Resolution without Increasing the Site-Survey Effort †

    PubMed Central

    Hernández, Noelia; Ocaña, Manuel; Alonso, Jose M.; Kim, Euntai

    2017-01-01

    Although much research has taken place in WiFi indoor localization systems, their accuracy can still be improved. When designing this kind of system, fingerprint-based methods are a common choice. The problem with fingerprint-based methods comes with the need of site surveying the environment, which is effort consuming. In this work, we propose an approach, based on support vector regression, to estimate the received signal strength at non-site-surveyed positions of the environment. Experiments, performed in a real environment, show that the proposed method could be used to improve the resolution of fingerprint-based indoor WiFi localization systems without increasing the site survey effort. PMID:28098773

  6. Research of cartographer laser SLAM algorithm

    NASA Astrophysics Data System (ADS)

    Xu, Bo; Liu, Zhengjun; Fu, Yiran; Zhang, Changsai

    2017-11-01

    As the indoor is a relatively closed and small space, total station, GPS, close-range photogrammetry technology is difficult to achieve fast and accurate indoor three-dimensional space reconstruction task. LIDAR SLAM technology does not rely on the external environment a priori knowledge, only use their own portable lidar, IMU, odometer and other sensors to establish an independent environment map, a good solution to this problem. This paper analyzes the Google Cartographer laser SLAM algorithm from the point cloud matching and closed loop detection. Finally, the algorithm is presented in the 3D visualization tool RViz from the data acquisition and processing to create the environment map, complete the SLAM technology and realize the process of indoor threedimensional space reconstruction

  7. [Inconsistencies between building regulations in force in Italy for indoor environment and wellness factors].

    PubMed

    Faggioli, A; Capasso, L

    2015-01-01

    Indoor environment is one of major health determinants, and the regulations that set the sanitary requirements are of primary importance for the protection of public health. The authors analyse the critical aspects of the complex Italian regulatory system, starting from the EU regulations, through national and regional laws, and finally the municipal regulations. They underline the need for more uniformity and clarity in the determination of health standards, as well as for a simplification of the existing legislation. Moreover, they highlight the importance of controlling and monitoring indoor environment, currently almost completely absent in Italy due to the effects of the regulatory changes of the latest years.

  8. Combustion Processes Indoors: a Source of High OH Radical Concentrations Through the Photolysis of Hono

    NASA Astrophysics Data System (ADS)

    Bartolomei, V.; Gomez Alvarez, E.; Glor, M.; Gligorovski, S.; Temime-Roussel, B.; Quivet, E.; Strekowski, R.; Zetzsch, C.; Held, A. B.; Wortham, H.

    2013-12-01

    Hydroxyl radical (OH) is one of the most important oxidant species in the atmosphere controlling its self-oxidizing capacity. The main sources of OH radicals are photolysis of ozone and photolysis of nitrous acid (HONO), among the others. In the indoor air, the ozonolysis of alkenes has been suggested as the main OH formation pathway. The possibility for OH formation through photolytic pathways in the indoor environment has been, up to now, ignored (Gómez Alvarez et al., 2012). Models and indirect measurements to the present time predicted concentrations of OH radicals in the order of 104 -105 cm-3. Recently, by direct measurements we have detected high OH radical concentrations of 1.8 106 cm-3 in a classroom in Marseille and we demonstrated that its main source is the photolysis of HONO (Gómez Alvarez et al., 2013). The concentrations of HONO are quite high indoors, reaching levels in the order of a few tens of ppbV (Gómez Alvarez et al., 2013). This is mainly due to 1) direct combustion sources and 2) heterogeneous reactions of NO2 on the numerous surfaces present in the indoor environment. HONO levels of 30 ppb were measured in a previous campaign carried out in Bayreuth in July 2012 as direct emissions from the combustion of a candle. The combination between so high concentrations of HONO and higher than expected light transmissions indoors (or indoor artificial lighting) could have a significant impact on the OH concentrations indoors which could feasibly become considerably higher than we measured in our school campaign (Gomez Alvarez et al., 2013). In order to evaluate these upper limits under combustion conditions in the indoor environment, we have carried out a campaign in the LOTASC chamber (Bayreuth, Germany). For this aim, the exhaust fumes from the burning of a commonly used domestic candle have been introduced in the chamber. The chamber was irradiated under well research indoor lighting conditions. A thorough characterization of light intensities and span (wavelength distribution) indoors have been performed, which had been identified as a clear flaw in our knowledge restricting the advancement of indoor air quality models. OH concentration levels have been determined using d9-butanol as tracer, using the OH clock determination procedure by PTR-MS-TOF. The OH radical concentration was investigated using different light intensities representative from indoor conditions, both natural and artificial and also different levels of RH. The PSS model has been performed in order to evaluate the contribution of different sources to the OH radical concentrations indoors under these conditions. The obtained results from the PSS model clearly indicate that the main source of OH radical indoors under combustion conditions is the photolysis of HONO under typical indoor irradiation conditions. REFERENCES Gómez Alvarez E, Wortham H, Strekowski R, Zetzsch C, Gligorovski S (2012) Atmospheric photo-sensitized heterogeneous and multiphase reactions: From outdoors to indoors, Environ. Sci. Technol. 46, 1955-1963. Gómez Alvarez, E.; Amedro, D.; Afif, C. ; Gligorovski, S.; Schoemacker , C.; Fittschen, C. ; Doussin, J. F.; Wortham, H. (2013) Unexpectedly high indoor hydroxyl radical concentrations associated with nitrous acid. Proc. Natl. Acad. Sci. USA Accepted.

  9. Become an Indoor airPLUS Verifier

    EPA Pesticide Factsheets

    With the Indoor airPLUS Program, 3rd-party verifiers help ensure that EPA's high standards, based on leading building science, are applied by the builder during home design and construction to meet the Indoor airPLUS Construction Specifications.

  10. Regulation and its role in the prevention of building-associated illness.

    PubMed

    Besch, E L

    1989-01-01

    Many groups have as their common goal the maintenance of acceptable indoor air quality, which protects occupants from adverse health effects and discomfort, but no one group possesses the interest or expertise to deal with all of the IAQ issues. Nonetheless, conclusions can be made regarding available alternatives to mitigate indoor air quality problems, including building-associated illness. It has been suggested that congressional action is needed in three areas related to BAI and IAQ: Recognition that controlling outdoor air only--even if "health based"--will not result in substantial improvement of public health; Definition of responsibilities for achieving healthful indoor environments; and Resolution of jurisdictional disputes between various federal agencies. Through their studies of buildings whose occupants complained of building-associated illness, NIOSH and others have concluded that inadequate supply and distribution of outdoor air to indoor spaces are the most common causes of SBS. Nonetheless, there are no reports of follow-up studies which confirm that the recommended ventilation upgrades actually solved the IAQ problems. Other reports indicate that maintenance, energy management, and air distribution are as important as ventilation rate. Corrective action, therefore, should include these issues. Systematic research directed toward providing cost-effective and innovative solutions should be the driving force. Rather than regulation, governments should assist in funding the necessary research, providing educational, technical and legal assistance, and developing policy options directed at reducing indoor air pollutants. In those cases where the specific causes of IAQ problems can be identified, remedial actions should be immediately implemented utilizing available technology. It has been suggested that "sick buildings" resulted from too much emphasis on efficency and safety and not enough on occupant health and well-being. Because health has been defined as "a state of complete physical, mental and social well-being not merely the absence of disease or infirmity," greater emphasis should be given to the concept of control and maintenance of healthy indoor environments (i.e., "healthy buildings") through utilization of quality assurance measures. Also, human response, system performance, and service factors should be utilized to assure an acceptable building performance. Finally, building designers, contractors, owners, managers, and operators must be knowledgeable regarding indoor air quality problems and their consequences and work together to build and maintain healthy buildings. This includes developing training, education, monitoring, and preventive maintenance programs to assure accountability for the proper management of the building systems. The certification (or licensing) of those responsible for providing indoor air quality has been suggested.

  11. CHILDREN'S HEALTH INITIATIVE: TOXIC MOLD (INDOOR ENVIRONMENT MANAGEMENT BRANCH, AIR POLLUTION PREVENTION AND CONTROL DIVISION, NRMRL)

    EPA Science Inventory

    The past 20 years have brought the recognition that an important factor in the health of people in indoor environments is the dampness of the buildings in which they live and work. Furthermore, it is now appreciated that the principal biology responsible for the health problems i...

  12. A Wheelchair User with Visual and Intellectual Disabilities Managing Simple Orientation Technology for Indoor Travel

    ERIC Educational Resources Information Center

    Lancioni, Giulio E.; O'Reilly, Mark F.; Singh, Nirbhay N.; Sigafoos, Jeff; Campodonico, Francesca; Oliva, Doretta

    2009-01-01

    Persons with profound visual impairments and other disabilities, such as neuromotor and intellectual disabilities, may encounter serious orientation and mobility problems even in familiar indoor environments, such as their homes. Teaching these persons to develop maps of their daily environment, using miniature replicas of the areas or some…

  13. Knowledge of the Effects of Indoor Air Quality on Health among Women in Jordan

    ERIC Educational Resources Information Center

    Madanat, Hala; Barnes, Michael D.; Cole, Eugene C.

    2008-01-01

    Objective: To assess the extent of knowledge about symptoms relating to respiratory illnesses and home environments among a random sample of 200 urban Jordanian women. Method: This customized, validated, cross-sectional questionnaire evaluated the knowledge of these women about the association between the indoor environment and health, the…

  14. Self-Organizing Distributed Architecture Supporting Dynamic Space Expanding and Reducing in Indoor LBS Environment

    PubMed Central

    Jeong, Seol Young; Jo, Hyeong Gon; Kang, Soon Ju

    2015-01-01

    Indoor location-based services (iLBS) are extremely dynamic and changeable, and include numerous resources and mobile devices. In particular, the network infrastructure requires support for high scalability in the indoor environment, and various resource lookups are requested concurrently and frequently from several locations based on the dynamic network environment. A traditional map-based centralized approach for iLBSs has several disadvantages: it requires global knowledge to maintain a complete geographic indoor map; the central server is a single point of failure; it can also cause low scalability and traffic congestion; and it is hard to adapt to a change of service area in real time. This paper proposes a self-organizing and fully distributed platform for iLBSs. The proposed self-organizing distributed platform provides a dynamic reconfiguration of locality accuracy and service coverage by expanding and contracting dynamically. In order to verify the suggested platform, scalability performance according to the number of inserted or deleted nodes composing the dynamic infrastructure was evaluated through a simulation similar to the real environment. PMID:26016908

  15. Energy, Weatherization and Indoor Air Quality

    EPA Pesticide Factsheets

    Climate change presents many challenges, including the production of severe weather events. These events and efforts to minimize their effects through weatherization can adversely affect indoor environments.

  16. Particulate Matter Mass Concentration in Residential Prefabricated Buildings Related to Temperature and Moisture

    NASA Astrophysics Data System (ADS)

    Kraus, Michal; Juhásová Šenitková, Ingrid

    2017-10-01

    Building environmental audit and the assessment of indoor air quality (IAQ) in typical residential buildings is necessary process to ensure users’ health and well-being. The paper deals with the concentrations on indoor dust particles (PM10) in the context of hygrothermal microclimate in indoor environment. The indoor temperature, relative humidity and air movement are basic significant factors determining the PM10 concentration [μg/m3]. The experimental measurements in this contribution represent the impact of indoor physical parameters on the concentration of particulate matter mass concentration. The occurrence of dust particles is typical for the almost two-thirds of interiors of the buildings. Other parameters indoor environment, such as air change rate, volume of the room, roughness and porosity of the building material surfaces, static electricity, light ions and others, were set constant and they are not taken into account in this study. The mass concentration of PM10 is measured during summer season in apartment of residential prefabricated building. The values of global temperature [°C] and relative humidity of indoor air [%] are also monitored. The quantity of particulate mass matter is determined gravimetrically by weighing according to CSN EN 12 341 (2014). The obtained results show that the temperature difference of the internal environment does not have a significant effect on the concentration PM10. Vice versa, the difference of relative humidity exhibits a difference of the concentration of dust particles. Higher levels of indoor particulates are observed for low values of relative humidity. The decreasing of relative air humidity about 10% caused 10µg/m3 of PM10 concentration increasing. The hygienic limit value of PM10 concentration is not exceeded at any point of experimental measurement.

  17. An Indoor Monitoring System for Ambient Assisted Living Based on Internet of Things Architecture

    PubMed Central

    Marques, Gonçalo; Pitarma, Rui

    2016-01-01

    The study of systems and architectures for ambient assisted living (AAL) is undoubtedly a topic of great relevance given the aging of the world population. The AAL technologies are designed to meet the needs of the aging population in order to maintain their independence as long as possible. As people typically spend more than 90% of their time in indoor environments, indoor air quality (iAQ) is perceived as an imperative variable to be controlled for the inhabitants’ wellbeing and comfort. Advances in networking, sensors, and embedded devices have made it possible to monitor and provide assistance to people in their homes. The continuous technological advancements make it possible to build smart objects with great capabilities for sensing and connecting several possible advancements in ambient assisted living systems architectures. Indoor environments are characterized by several pollutant sources. Most of the monitoring frameworks instantly accessible are exceptionally costly and only permit the gathering of arbitrary examples. iAQ is an indoor air quality system based on an Internet of Things paradigm that incorporates in its construction Arduino, ESP8266, and XBee technologies for processing and data transmission and micro sensors for data acquisition. It also allows access to data collected through web access and through a mobile application in real time, and this data can be accessed by doctors in order to support medical diagnostics. Five smaller scale sensors of natural parameters (air temperature, moistness, carbon monoxide, carbon dioxide, and glow) were utilized. Different sensors can be included to check for particular contamination. The results reveal that the system can give a viable indoor air quality appraisal in order to anticipate technical interventions for improving indoor air quality. Indeed indoor air quality might be distinctively contrasted with what is normal for a quality living environment. PMID:27869682

  18. An Indoor Monitoring System for Ambient Assisted Living Based on Internet of Things Architecture.

    PubMed

    Marques, Gonçalo; Pitarma, Rui

    2016-11-17

    The study of systems and architectures for ambient assisted living (AAL) is undoubtedly a topic of great relevance given the aging of the world population. The AAL technologies are designed to meet the needs of the aging population in order to maintain their independence as long as possible. As people typically spend more than 90% of their time in indoor environments, indoor air quality (iAQ) is perceived as an imperative variable to be controlled for the inhabitants' wellbeing and comfort. Advances in networking, sensors, and embedded devices have made it possible to monitor and provide assistance to people in their homes. The continuous technological advancements make it possible to build smart objects with great capabilities for sensing and connecting several possible advancements in ambient assisted living systems architectures. Indoor environments are characterized by several pollutant sources. Most of the monitoring frameworks instantly accessible are exceptionally costly and only permit the gathering of arbitrary examples. iAQ is an indoor air quality system based on an Internet of Things paradigm that incorporates in its construction Arduino, ESP8266, and XBee technologies for processing and data transmission and micro sensors for data acquisition. It also allows access to data collected through web access and through a mobile application in real time, and this data can be accessed by doctors in order to support medical diagnostics. Five smaller scale sensors of natural parameters (air temperature, moistness, carbon monoxide, carbon dioxide, and glow) were utilized. Different sensors can be included to check for particular contamination. The results reveal that the system can give a viable indoor air quality appraisal in order to anticipate technical interventions for improving indoor air quality. Indeed indoor air quality might be distinctively contrasted with what is normal for a quality living environment.

  19. Quantifying the contribution of ambient and indoor-generated fine particles to indoor air in residential environments.

    PubMed

    MacNeill, M; Kearney, J; Wallace, L; Gibson, M; Héroux, M E; Kuchta, J; Guernsey, J R; Wheeler, A J

    2014-08-01

    Indoor fine particles (FPs) are a combination of ambient particles that have infiltrated indoors, and particles that have been generated indoors from activities such as cooking. The objective of this paper was to estimate the infiltration factor (Finf ) and the ambient/non-ambient components of indoor FPs. To do this, continuous measurements were collected indoors and outdoors for seven consecutive days in 50 non-smoking homes in Halifax, Nova Scotia in both summer and winter using DustTrak (TSI Inc) photometers. Additionally, indoor and outdoor gravimetric measurements were made for each 24-h period in each home, using Harvard impactors (HI). A computerized algorithm was developed to remove (censor) peaks due to indoor sources. The censored indoor/outdoor ratio was then used to estimate daily Finfs and to determine the ambient and non-ambient components of total indoor concentrations. Finf estimates in Halifax (daily summer median = 0.80; daily winter median = 0.55) were higher than have been reported in other parts of Canada. In both winter and summer, the majority of FP was of ambient origin (daily winter median = 59%; daily summer median = 84%). Predictors of the non-ambient component included various cooking variables, combustion sources, relative humidity, and factors influencing ventilation. This work highlights the fact that regional factors can influence the contribution of ambient particles to indoor residential concentrations. Ambient and non-ambient particles have different risk management approaches, composition, and likely toxicity. Therefore, a better understanding of their contribution to the indoor environment is important to manage the health risks associated with fine particles (FPs) effectively. As well, a better understanding of the factors Finf can help improve exposure assessment and contribute to reduced exposure misclassification in epidemiologic studies. © 2013 Her Majesty the Queen in Right of Canada Indoor Air © 2013 John Wiley & Sons Ltd Reproduced with the permission of the Minister of Health Canada.

  20. Particle characterization in retail environments: concentrations, sources, and removal mechanisms.

    PubMed

    Zaatari, M; Siegel, J

    2014-08-01

    Particles in retail environments can have consequences for the occupational exposures of retail workers and customers, as well as the energy costs associated with ventilation and filtration. Little is known about particle characteristics in retail environments. We measured indoor and outdoor mass concentrations of PM10 and PM2.5 , number concentrations of submicron particles (0.02-1 μm), size-resolved 0.3-10 μm particles, as well as ventilation rates in 14 retail stores during 24 site visits in Pennsylvania and Texas. Overall, the results were generally suggestive of relatively clean environments when compared to investigations of other building types and ambient/occupational regulatory limits. PM10 and PM2.5 concentrations (mean ± s.d.) were 20 ± 14 and 11 ± 10 μg/m(3), respectively, with indoor-to-outdoor ratios of 1.0 ± 0.7 and 0.88 ± 1.0. Mean submicron particle concentrations were 7220 ± 7500 particles/cm(3) with an indoor-to-outdoor ratio of 1.18 ± 1.30. The median contribution to PM10 and PM2.5 concentrations from indoor sources (vs. outdoors) was 83% and 53%, respectively. There were no significant correlations between measured ventilation rates and particle concentrations of any size. When examining options to lower PM2.5 concentrations below regulatory limits, the required changes to ventilation and filtration efficiency were site specific and depended on the indoor and outdoor concentration, emission rate, and infiltration level. Little is known about particle concentrations, contribution of indoor sources, and emission rates in retail environments. Knowledge of these particle characteristics informs health scientists with input parameters to include in exposure modeling. The predicted concentration change in response to different ventilation rates and filtration efficiencies may be used for guidance to develop control strategies to lower particulate matter concentrations in retail environments. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. PROGRAM PARAMS USERS GUIDE

    EPA Science Inventory

    PARAMS is a Windows-based computer program that implements 30 methods for estimating the parameters in indoor emissions source models, which are an essential component of indoor air quality (IAQ) and exposure models. These methods fall into eight categories: (1) the properties o...

  2. Doris A. Betancourt, Ph.D.

    EPA Pesticide Factsheets

    Request an environmental microbiologist. Her current research deals with screening indoor biocontaminutesants. She is responsible for the identification and characterization of mold, bacteria, and their metabolites in indoor environments.

  3. Impact of Indoor Environment on Path Loss in Body Area Networks

    PubMed Central

    Hausman, Sławomir; Januszkiewicz, Łukasz

    2014-01-01

    In this paper the influence of an example indoor environment on narrowband radio channel path loss for body area networks operating around 2.4 GHz is investigated using computer simulations and on-site measurements. In contrast to other similar studies, the simulation model included both a numerical human body phantom and its environment—room walls, floor and ceiling. As an example, radio signal attenuation between two different configurations of transceivers with dipole antennas placed in a direct vicinity of a human body (on-body scenario) is analyzed by computer simulations for several types of reflecting environments. In the analyzed case the propagation environments comprised a human body and office room walls. As a reference environment for comparison, free space with only a conducting ground plane, modelling a steel mesh reinforced concrete floor, was chosen. The transmitting and receiving antennas were placed in two on-body configurations chest–back and chest–arm. Path loss vs. frequency simulation results obtained using Finite Difference Time Domain (FDTD) method and a multi-tissue anthropomorphic phantom were compared to results of measurements taken with a vector network analyzer with a human subject located in an average-size empty cuboidal office room. A comparison of path loss values in different environments variants gives some qualitative and quantitative insight into the adequacy of simplified indoor environment model for the indoor body area network channel representation. PMID:25333289

  4. Understanding the impact of molds on indoor air quality and possible links to health effects Indoor Molds - More than Just a Musty Smell

    EPA Science Inventory

    Molds are multi-celled, colony forming, eukaryotic microorganisms lacking chlorophyll belonging to the Kingdom Fungi. Furthermore, molds are ubiquitous in both indoor and outdoor environments. There are more than 200 different types of fungi to which people are routinely exposed ...

  5. Indoor Air Quality: A Guide for Educators.

    ERIC Educational Resources Information Center

    California State Dept. of Education, Sacramento.

    Indoor air quality is a major concern for educators involved in the development of new school facilities, or the remodeling and maintenance of existing ones. This guide addresses the issue of air quality, the health concerns involved, and procedures for minimizing the impact of pollutants in the school environment. It defines common indoor air…

  6. VOLATILE ORGANIC COMPOUND EMISSIONS FROM LATEX PAINT-PART 2. TEST HOUSE STUDIES AND INDOOR AIR QUALITY (IAQ) MODELING

    EPA Science Inventory

    Emission models developed using small chamber data were combined with an Indoor Air Quality (IAQ) model to analyze the impact of volatile organic compound (VOC) emissions from latex paint on indoor environments. Test house experiments were conducted to verify the IAQ model's pred...

  7. Environment and development of respiratory allergy. II. Indoors.

    PubMed

    D'Amato, G; Liccardi, G; D'Amato, M

    1994-12-01

    Even if it is difficult to obtain correct epidemiological evidence, there is a body of evidence which suggests that the frequency of allergic respiratory diseases is increasing. The majority of atopic patients, in particular in childhood and adolescence, develop immunoglobulin E (IgE) antibodies with clinical symptoms to aeroallergens, such as those derived from house dust mites, pollens and pets. Since, in the economically-developed countries individuals spend most of their time indoors (home, school and workplace), indoor pollutants (tobacco smoke etc.) and allergens (house dust mite, cats, etc.) are the most important source of exposure. Indoor allergens are associated with a wide variety of particles in a broad size range, only some of which are microscopically identifiable, culturable, or detectable with existing immunoassay. Evaluation of indoor allergens requires both air and source sampling, and several different analytical techniques. It is likely that the increased prevalence of allergy and asthma may be caused in the indoor environment by the synergistic action of air pollution (in particular derived from tobacco smoking) with allergic sensitization. Passive smoking in infancy has also been involved in the airways allergic sensitization to common aeroallergens.

  8. Ultra Wideband Indoor Positioning Technologies: Analysis and Recent Advances †

    PubMed Central

    Alarifi, Abdulrahman; Al-Salman, AbdulMalik; Alsaleh, Mansour; Alnafessah, Ahmad; Al-Hadhrami, Suheer; Al-Ammar, Mai A.; Al-Khalifa, Hend S.

    2016-01-01

    In recent years, indoor positioning has emerged as a critical function in many end-user applications; including military, civilian, disaster relief and peacekeeping missions. In comparison with outdoor environments, sensing location information in indoor environments requires a higher precision and is a more challenging task in part because various objects reflect and disperse signals. Ultra WideBand (UWB) is an emerging technology in the field of indoor positioning that has shown better performance compared to others. In order to set the stage for this work, we provide a survey of the state-of-the-art technologies in indoor positioning, followed by a detailed comparative analysis of UWB positioning technologies. We also provide an analysis of strengths, weaknesses, opportunities, and threats (SWOT) to analyze the present state of UWB positioning technologies. While SWOT is not a quantitative approach, it helps in assessing the real status and in revealing the potential of UWB positioning to effectively address the indoor positioning problem. Unlike previous studies, this paper presents new taxonomies, reviews some major recent advances, and argues for further exploration by the research community of this challenging problem space. PMID:27196906

  9. Ultra Wideband Indoor Positioning Technologies: Analysis and Recent Advances.

    PubMed

    Alarifi, Abdulrahman; Al-Salman, AbdulMalik; Alsaleh, Mansour; Alnafessah, Ahmad; Al-Hadhrami, Suheer; Al-Ammar, Mai A; Al-Khalifa, Hend S

    2016-05-16

    In recent years, indoor positioning has emerged as a critical function in many end-user applications; including military, civilian, disaster relief and peacekeeping missions. In comparison with outdoor environments, sensing location information in indoor environments requires a higher precision and is a more challenging task in part because various objects reflect and disperse signals. Ultra WideBand (UWB) is an emerging technology in the field of indoor positioning that has shown better performance compared to others. In order to set the stage for this work, we provide a survey of the state-of-the-art technologies in indoor positioning, followed by a detailed comparative analysis of UWB positioning technologies. We also provide an analysis of strengths, weaknesses, opportunities, and threats (SWOT) to analyze the present state of UWB positioning technologies. While SWOT is not a quantitative approach, it helps in assessing the real status and in revealing the potential of UWB positioning to effectively address the indoor positioning problem. Unlike previous studies, this paper presents new taxonomies, reviews some major recent advances, and argues for further exploration by the research community of this challenging problem space.

  10. Composition and Source Identification of Chemical Species in Dust from Selected Indoor Environments in Ile-Ife, Nigeria

    NASA Astrophysics Data System (ADS)

    Ogundele, Lasun T.; Olasinde, Roseline T.; Owoade, Oyediran K.; Olise, Felix S.

    2018-05-01

    This study presents the elemental compositions and concentrations of indoor dust and identifies the major sources in some selected indoor environments in Ile-Ife, Nigeria. The dust samples were collected from 16 indoor environments comprising offices, churches, residential and staff quarters using a cyclonic high power vacuum cleaner. The dust samples were analyzed for elemental concentrations using x-ray fluorescences. The data sets were analyzed for the possible sources and their contributions using Principal Component Factor Analysis (PCFA). The result showed that dust samples contained several elements: K, Ca, Ti, Mn, Fe, Ni, Cu, Zn, Ga, As, Rb, Sr, Se, Zr, V, and Sc. The PCFA identified three factors with the percentage variance of 92, 77, 71 and 68%, for the office, church, residential, and staff quarters, respectively, for the combined elemental data of each of the site classes. The identified sources were track-in-soil, road and windblown soil dust, paint debris, household dust from personal care materials, cooking, and cleaning activities. The unintentional track-in-soil due to mobility of the occupants, structural materials, and outdoor air was the major sources contributing to the indoor dust.

  11. Investigation on Indoor Air Pollution and Childhood Allergies in Households in Six Chinese Cities by Subjective Survey and Field Measurements

    PubMed Central

    Hu, Jinhua; Li, Nianping; Lv, Yang; Liu, Jing; Xie, Jingchao; Zhang, Huibo

    2017-01-01

    Greater attention is currently being paid to the relationship between indoor environment and childhood allergies, however, the lack of reliable data and the disparity among different areas hinders reliable assessment of the relationship. This study focuses on the effect of indoor pollution on Chinese schoolchildren and the relationship between specific household and health problems suffered. The epidemiological questionnaire survey and the field measurement of the indoor thermal environment and primary air pollutants including CO2, fine particulate matter (PM2.5), chemical pollutants and fungi were performed in six Chinese cities. A total of 912 questionnaires were eligible for statistical analyses and sixty houses with schoolchildren aged 9–12 were selected for field investigation. Compared with Chinese national standards, inappropriate indoor relative humidity (<30% or >70%), CO2 concentration exceeding 1000 ppm and high PM2.5 levels were found in some monitored houses. Di(2-ethylhexyl) phthalate (DEHP) and dibutyl phthalate (DBP) were the most frequently detected semi-volatile organic compounds (SVOCs) in house dust. Cladosporium, Aspergillus and Penicillium were detected in both indoor air and house dust. This study indicates that a thermal environment with CO2 exceeding 1000 ppm, DEHP and DBP exceeding 1000 μg/g, and high level of PM2.5, Cladosporium, Aspergillus and Penicillium increases the risk of children’s allergies. PMID:28850091

  12. Occurrence of the off-host life stages of Tunga penetrans (Siphonaptera) in various environments in Brazil.

    PubMed

    Linardi, P M; Calheiros, C M L; Campelo-Junior, E B; Duarte, E M; Heukelbach, J; Feldmeier, H

    2010-06-01

    To explore the local transmission dynamics of Tunga penetrans in brazil, 134 soil samples from various environments were collected in three different endemic regions of the country and checked for the presence of the flea's larvae, pupae and adults. the samples, which came from an urban slum in the north-east, a village of xavante indians in the central-west and a community of yanomami indians living in traditional longhouses (malocas) in the north, were categorized as indoor, outdoor or indoor-outdoor (the latter representing samples collected in the malocas). The proportion of samples found positive for T. penetrans was lowest in the slum (9.3%) and highest in the Yanomami village (32.0%; P=0.01). Soil samples collected below bedsteads or hammocks or from the indoor resting places of dogs were significantly more likely to be positive than the indoor samples collected at other sites (65.0% v. 35.0%; P=0.02). There was no evidence indicating that the presence of T. penetrans in a soil sample was markedly affected by soil temperature, air temperature or air humidity. As no life stages of T. penetrans were found in any outdoor sample, it seems likely that, in resource-poor settings in Brazil, most transmission of T. penetrans occurs indoors. Control measures against the off-host life stages of T. penetrans should therefore be targeted at particular indoor micro-environments.

  13. Investigation on Indoor Air Pollution and Childhood Allergies in Households in Six Chinese Cities by Subjective Survey and Field Measurements.

    PubMed

    Hu, Jinhua; Li, Nianping; Lv, Yang; Liu, Jing; Xie, Jingchao; Zhang, Huibo

    2017-08-29

    Greater attention is currently being paid to the relationship between indoor environment and childhood allergies, however, the lack of reliable data and the disparity among different areas hinders reliable assessment of the relationship. This study focuses on the effect of indoor pollution on Chinese schoolchildren and the relationship between specific household and health problems suffered. The epidemiological questionnaire survey and the field measurement of the indoor thermal environment and primary air pollutants including CO₂, fine particulate matter (PM 2.5 ), chemical pollutants and fungi were performed in six Chinese cities. A total of 912 questionnaires were eligible for statistical analyses and sixty houses with schoolchildren aged 9-12 were selected for field investigation. Compared with Chinese national standards, inappropriate indoor relative humidity (<30% or >70%), CO₂ concentration exceeding 1000 ppm and high PM 2.5 levels were found in some monitored houses. Di(2-ethylhexyl) phthalate (DEHP) and dibutyl phthalate (DBP) were the most frequently detected semi-volatile organic compounds (SVOCs) in house dust. Cladosporium , Aspergillus and Penicillium were detected in both indoor air and house dust. This study indicates that a thermal environment with CO₂ exceeding 1000 ppm, DEHP and DBP exceeding 1000 μg/g, and high level of PM 2.5 , Cladosporium , Aspergillus and Penicillium increases the risk of children's allergies.

  14. Nicotine as a Marker for Environmental Tobacco Smoke: Implications of Sorption on Indoor Surface Materials.

    PubMed

    Van Loy, Michael D; Nazaroff, William W; Daisey, Joan M

    1998-10-01

    Recently developed models and data describing the interactions of gas-phase semi-volatile organic compounds with indoor surfaces are employed to examine the effects of sorption on nicotine's suitability as an environmental tobacco smoke (ETS) marker. Using parameters from our studies of nicotine sorption on carpet, painted wallboard, and stainless steel and previously published data on ETS particle deposition, the dynamic behavior of nicotine was modeled in two different indoor environments: a house and a stainless steel chamber. The results show that apparently contradictory observations of nicotine's behavior in indoor air can be understood by considering the effects of sorption under different experimental conditions. In indoor environments in which smoking has occurred regularly for an extended period, the sorbed mass of nicotine is very large relative to the mass emitted by a single cigarette. The importance of nicotine adsorption relative to ventilation as a gas-phase removal mechanism is reduced. Where smoking occurs less regularly or the indoor surfaces are cleaned prior to smoking (as in a laboratory chamber), nicotine deposition is more significant. Nicotine concentrations closely track the levels of other ETS constituents in environments with habitual smoking if the data are averaged over a period significantly longer than the period between cigarette combustion episodes. However, nicotine is not a suitable tracer for predicting ETS exposures at fine time scales or in settings where smoking occurs infrequently and irregularly.

  15. Influence of indoor environmental factors on mass transfer parameters and concentrations of semi-volatile organic compounds.

    PubMed

    Wei, Wenjuan; Mandin, Corinne; Ramalho, Olivier

    2018-03-01

    Semi-volatile organic compounds (SVOCs) in indoor environments can partition among the gas phase, airborne particles, settled dust, and available surfaces. The mass transfer parameters of SVOCs, such as the mass transfer coefficient and the partition coefficient, are influenced by indoor environmental factors. Subsequently, indoor SVOC concentrations and thus occupant exposure can vary depending on environmental factors. In this review, the influence of six environmental factors, i.e., indoor temperature, humidity, ventilation, airborne particle concentration, source loading factor, and reactive chemistry, on the mass transfer parameters and indoor concentrations of SVOCs was analyzed and tentatively quantified. The results show that all mass transfer parameters vary depending on environmental factors. These variations are mostly characterized by empirical equations, particularly for humidity. Theoretical calculations of these parameters based on mass transfer mechanisms are available only for the emission of SVOCs from source surfaces when airborne particles are not present. All mass transfer parameters depend on the temperature. Humidity influences the partition of SVOCs among different phases and is associated with phthalate hydrolysis. Ventilation has a combined effect with the airborne particle concentration on SVOC emission and their mass transfer among different phases. Indoor chemical reactions can produce or eliminate SVOCs slowly. To better model the dynamic SVOC concentration indoors, the present review suggests studying the combined effect of environmental factors in real indoor environments. Moreover, interactions between indoor environmental factors and human activities and their influence on SVOC mass transfer processes should be considered. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. The effect of indoor office environment on the work performance, health and well-being of office workers.

    PubMed

    Vimalanathan, Komalanathan; Ramesh Babu, Thangavelu

    2014-01-01

    The effect of indoor environment may have an influence on the performance, productivity health and well-being of office workers. Environmental factors such as indoor temperature and illumination have been investigated at three levels. A neurobehavioral test (NBT) has been proposed for the evaluation of office workersc performance. A field lab to emulate an office has been created. In controlled condition of environmental factors, the neurobehavioral test was conducted. The response time and the number of errors in each test have been recorded. A randomized block factorial design was used to analyze the responses of office worker's performance. The results revealed that the independent and interaction effect of temperature and illumination have significant effect on the office workers' performance. The effect of indoor room temperature has more influences than the effect of illumination. The effect of indoor temperature has 38.56% of contribution on the performance. The optimum levels of indoor temperature at 21°C and illumination at 1000 lux have improved the work performance and health of office workers. The indoor room temperature and illumination are more influence on the performance of the office workers. It may be concluded that the impact of indoor room temperature (38.56%) is more on the office worker's performance than the effect of illumination (19.91%). Further, it may be concluded that the optimum level of indoor room temperature (21°C) and illumination (1000lux) have improved the work performance, health and productivity of office workers.

  17. [Enclosed environments and health].

    PubMed

    Maroni, M; Barbieri, F

    1989-01-01

    Problems related to Indoor Air Quality are subject of study since about twenty years. New architectural criteria, new building materials and increasing demands of energy saving have progressively changed residences, offices and all non-industrial indoor environments. This paper present a review of the IAQ-related issues from sources characterization, to pollutant assessment and definition of effects on human health.

  18. INVESTIGATION OF THE INDOOR AIR QUALITY OF THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES AT 3800 BARRETT DRIVE, RALEIGH, NC

    EPA Science Inventory

    A limited-scale indoor air quality investigation was conducted over a 4 day period at the North Carolina Department of Environment, Health, and Natural Resources' offices located at 3800 Barrett Drive, Raleigh, NC. Integrated 9 hour particle, aldehyde, and volatile organic compou...

  19. Thermal Analysis--Human Comfort--Indoor Environments. NBS Special Publication 491.

    ERIC Educational Resources Information Center

    Mangum, Billy W., Ed.; Hill, James E., Ed.

    Included in these proceedings are 11 formal papers presented by leading researchers in the field of thermal comfort and heat stress at a symposium held for the purpose of exploring new aspects of indoor thermal environments, caused primarily by the impact of energy conservation in new and existing buildings. The contributed papers were from…

  20. Integrated analysis of numerical weather prediction and computational fluid dynamics for estimating cross-ventilation effects on inhaled air quality inside a factory

    NASA Astrophysics Data System (ADS)

    Murga, Alicia; Sano, Yusuke; Kawamoto, Yoichi; Ito, Kazuhide

    2017-10-01

    Mechanical and passive ventilation strategies directly impact indoor air quality. Passive ventilation has recently become widespread owing to its ability to reduce energy demand in buildings, such as the case of natural or cross ventilation. To understand the effect of natural ventilation on indoor environmental quality, outdoor-indoor flow paths need to be analyzed as functions of urban atmospheric conditions, topology of the built environment, and indoor conditions. Wind-driven natural ventilation (e.g., cross ventilation) can be calculated through the wind pressure coefficient distributions of outdoor wall surfaces and openings of a building, allowing the study of indoor air parameters and airborne contaminant concentrations. Variations in outside parameters will directly impact indoor air quality and residents' health. Numerical modeling can contribute to comprehend these various parameters because it allows full control of boundary conditions and sampling points. In this study, numerical weather prediction modeling was used to calculate wind profiles/distributions at the atmospheric scale, and computational fluid dynamics was used to model detailed urban and indoor flows, which were then integrated into a dynamic downscaling analysis to predict specific urban wind parameters from the atmospheric to built-environment scale. Wind velocity and contaminant concentration distributions inside a factory building were analyzed to assess the quality of the human working environment by using a computer simulated person. The impact of cross ventilation flows and its variations on local average contaminant concentration around a factory worker, and inhaled contaminant dose, were then discussed.

  1. Perceived Indoor Environment and Occupants' Comfort in European "Modern" Office Buildings: The OFFICAIR Study.

    PubMed

    Sakellaris, Ioannis A; Saraga, Dikaia E; Mandin, Corinne; Roda, Célina; Fossati, Serena; de Kluizenaar, Yvonne; Carrer, Paolo; Dimitroulopoulou, Sani; Mihucz, Victor G; Szigeti, Tamás; Hänninen, Otto; de Oliveira Fernandes, Eduardo; Bartzis, John G; Bluyssen, Philomena M

    2016-04-25

    Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers' comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants' comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 "modern" office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants' comfort. The highest association with occupants' overall comfort was found for "noise", followed by "air quality", "light" and "thermal" satisfaction. Analysis of detailed parameters revealed that "noise inside the buildings" was highly associated with occupants' overall comfort. "Layout of the offices" was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building's location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants.

  2. Perceived Indoor Environment and Occupants’ Comfort in European “Modern” Office Buildings: The OFFICAIR Study

    PubMed Central

    Sakellaris, Ioannis A.; Saraga, Dikaia E.; Mandin, Corinne; Roda, Célina; Fossati, Serena; de Kluizenaar, Yvonne; Carrer, Paolo; Dimitroulopoulou, Sani; Mihucz, Victor G.; Szigeti, Tamás; Hänninen, Otto; de Oliveira Fernandes, Eduardo; Bartzis, John G.; Bluyssen, Philomena M.

    2016-01-01

    Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers’ comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants’ comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 “modern” office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants’ comfort. The highest association with occupants’ overall comfort was found for “noise”, followed by “air quality”, “light” and “thermal” satisfaction. Analysis of detailed parameters revealed that “noise inside the buildings” was highly associated with occupants’ overall comfort. “Layout of the offices” was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building’s location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants. PMID:27120608

  3. Creating Ideal Facilities.

    ERIC Educational Resources Information Center

    Kennedy, Mike

    2002-01-01

    Reviews ways that schools can provide effective indoor learning environments by paying attention to the following areas: daylighting, acoustics, space allocation, technology implementation, ergonomics, maintenance, indoor air quality, safety, restrooms, and roofing. (GR)

  4. Indoor climate and air quality . Review of current and future topics in the field of ISB study group 10

    NASA Astrophysics Data System (ADS)

    Höppe, P.; Martinac, Ivo

    In industrialized countries about 90% of the time is spent indoors. The ambient parameters affecting indoor thermal comfort are air temperature and humidity, air velocity, and radiant heat exchange within an enclosure. In assessing the thermal environment, one needs to consider all ambient parameters, the insulating properties of the occupants' clothing, and the activity level of the occupants by means of heat balance models of the human body. Apart from thermal parameters, air quality (measured and perceived) is also of importance for well-being and health in indoor environments. Pollutant levels are influenced by both outdoor concentrations and by indoor emissions. Indoor levels can thus be lower (e.g. in the case of ozone and SO2) or higher (e.g. for CO2 and formaldehyde) than outdoor levels. Emissions from cooking play an important role, especially in developing countries. The humidity of the ambient air has a wide range of effects on the energy and water balance of the body as well as on elasticity, air quality perception, build-up of electrostatic charge and the formation or mould. However, its effect on the indoor climate is often overestimated. While air-handling systems are commonly used for achieving comfortable indoor climates, their use has also been linked to a variety of problems, some of which have received attention within the context of ''sick building syndrome''.

  5. Indoor climate and air quality. Review of current and future topics in the field of ISB study group 10.

    PubMed

    Höppe, P; Martinac, I

    1998-08-01

    In industrialized countries about 90% of the time is spent indoors. The ambient parameters affecting indoor thermal comfort are air temperature and humidity, air velocity, and radiant heat exchange within an enclosure. In assessing the thermal environment, one needs to consider all ambient parameters, the insulating properties of the occupants' clothing, and the activity level of the occupants by means of heat balance models of the human body. Apart from thermal parameters, air quality (measured and perceived) is also of importance for well-being and health in indoor environments. Pollutant levels are influenced by both outdoor concentrations and by indoor emissions. Indoor levels can thus be lower (e.g. in the case of ozone and SO2) or higher (e.g. for CO2 and formaldehyde) than outdoor levels. Emissions from cooking play an important role, especially in developing countries. The humidity of the ambient air has a wide range of effects on the energy and water balance of the body as well as on elasticity, air quality perception, build-up of electrostatic charge and the formation or mould. However, its effect on the indoor climate is often overestimated. While air-handling systems are commonly used for achieving comfortable indoor climates, their use has also been linked to a variety of problems, some of which have received attention within the context of "sick building syndrome".

  6. INDOOR AIR QUALITY AND INHALATION EXPOSURE - SIMULATION TOOL KIT

    EPA Science Inventory

    A Microsoft Windows-based indoor air quality (IAQ) simulation software package is presented. Named Simulation Tool Kit for Indoor Air Quality and Inhalation Exposure, or IAQX for short, this package complements and supplements existing IAQ simulation programs and is desi...

  7. Adapting Buildings for Indoor Air Quality in a Changing Climate

    EPA Pesticide Factsheets

    Climate change presents many challenges, including the production of severe weather events. These events and efforts to minimize their effects through weatherization can adversely affect indoor environments.

  8. National Weatherization Assistance Program Impact Evaluation: Impact of Exhaust-Only Ventilation on Radon and Indoor Humidity - A Field Investigation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pigg, Scott

    2014-09-01

    The study described here sought to assess the impact of exhaust-only ventilation on indoor radon and humidity in single-family homes that had been treated by the Weatherization Assistance Program (WAP).

  9. ASSESSING ALLERGENICITY OF INDOOR AIR FUNGAL CONTAMINANTS

    EPA Science Inventory

    Assessing Allergenicity of Indoor Air Fungal Contaminants
    M D W Ward1, M E Viana2, N Haykal-Coates1, L B Copeland1, S H Gavett1, and MJ K Selgrade1. 1US EPA, ORD, NHEERL, RTP, NC, USA. 2NCSU, CVM, Raleigh, NC, USA.
    Rationale: The indoor environment has increased in impor...

  10. Indoor Air Quality: Tools for Schools Action Kit.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Indoor Air Div.

    Good indoor air quality contributes to a favorable learning environment for students, productivity for teachers and staff, and a sense of comfort, health, and well-being for all school occupants. The goal of this kit is to provide clear and easily applied guidance that will help prevent Indoor Air Quality (IAQ) problems and resolve such problems…

  11. Biodiversity and concentrations of airborne fungi in large US office buildings from the BASE study

    NASA Astrophysics Data System (ADS)

    Tsai, Feng C.; Macher, Janet M.; Hung, Yun-Yi

    The Building Assessment Survey and Evaluation (BASE) study measured baseline concentrations of airborne fungi in 100 representative US office buildings in 1994-1998. Multiple samples for different sampling durations, sites, and times of the day were aggregated into building-wide indoor and outdoor average concentrations. Fungal concentrations were compared between locations (indoor vs. outdoor), sampling and analytical methods (culture vs. microscopy), and season (summer vs. winter). The arithmetic means (standard deviations) of the indoor/outdoor concentrations of culturable fungi and fungal spores were 100/680 (230/840) CFUm-3 and 270/6540 (1190/6780) sporem-3, respectively. Although fewer groups were observed indoors than outdoors, at lower average concentrations (except in two buildings), site-specific and building-wide indoor measurements had higher coefficients of variation. More groups were seen in summer, and aggregated concentrations tended to be higher than in winter except for culturable Aureobasidium spp. and Botrytis spp. outdoors and non-sporulating fungi in both locations. Rankings of the predominant fungi identified by both methods were similar, but overall indoor and outdoor spore concentrations were approximately 3 and 10 times higher, respectively, than concentrations of culturable fungi. In the 44 buildings with both measurements, the indoor and outdoor total culturable fungi to fungal spore ratios (total C/S ratios) were 1.27 and 0.25, with opposite seasonal patterns. The indoor C/S ratio was higher in summer than in winter (1.47 vs. 0.86; N=29 and 15, respectively), but the outdoor ratio was lower in summer (0.19 vs. 0.36, respectively). Comparison of the number of different fungal groups and individual occurrence in buildings and samples indicated that the outdoor environment and summer season were more diverse, but the proportional contributions of the groups were very similar suggesting that the indoor and outdoor environments were related as were summer and winter seasons for each location. The extreme (e.g., 90th percentile) indoor concentrations ( 200CFUm-3 and 210sporem-3) may provide reference values for non-complaint US office environments.

  12. Detection of fluorotelomer alcohols in indoor environments and their relevance for human exposure.

    PubMed

    Schlummer, Martin; Gruber, Ludwig; Fiedler, Dominik; Kizlauskas, Markus; Müller, Josef

    2013-07-01

    Fluorotelomer alcohols (FTOH) are important precursors of perfluorinated carboxylic acids (PFCA). These neutral and volatile compounds are frequently found in indoor air and may contribute to the overall human exposure to per- and polyfluorinated alkyl substances (PFAS). In this study air samples of ten workplace environments and a car interior were analysed. In addition, extracts and emissions from selected outdoor textiles were analysed in order to establish their potential contribution to the indoor levels of the above-mentioned compounds. Concentrations of FTOHs measured in air ranged from 0.15 to 46.8, 0.25 to 286, and 0.11 to 57.5ng/m(3) for 6:2, 8:2 and 10:2 FTOHs, respectively. The highest concentrations in air were identified in shops selling outdoor clothing, indicating outdoor textiles to be a relevant source of FTOH in indoor workplace environments. Total amounts of FTOH in materials of outdoor textiles accounted for <0.8-7.6, 12.1-180.9 and 4.65-105.7μg/dm(2) for 6:2, 8:2 and 10:2 FTOHs, respectively. Emission from selected textiles revealed emission rates of up to 494ng/h. The measured data show that a) FTOHs are present in indoor textiles (e.g. carpets), b) they are released at ambient temperatures and c) indoor air of shops selling outdoor textiles contains the highest levels of FTOH. Exposure of humans to perfluorooctanoic acid (PFOA) through absorption of FTOH and subsequent degradation is discussed on the basis of indoor air levels. Calculation of indoor air-related exposure using the median of the measured air levels revealed that exposure is on the same order of magnitude as the recently reported dietary intakes for a background-exposed population. On the basis of the 95th percentile, indoor air exposure to PFOA was estimated to exceed dietary exposure. However, indoor air-related intakes of FTOH are far below the tolerable daily intake (TDI) of PFOA, indicating that there is no risk to health, even when assuming an unrealistic complete degradation of FTOH into PFOA. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. An Indoor Positioning Method for Smartphones Using Landmarks and PDR.

    PubMed

    Wang, Xi; Jiang, Mingxing; Guo, Zhongwen; Hu, Naijun; Sun, Zhongwei; Liu, Jing

    2016-12-15

    Recently location based services (LBS) have become increasingly popular in indoor environments. Among these indoor positioning techniques providing LBS, a fusion approach combining WiFi-based and pedestrian dead reckoning (PDR) techniques is drawing more and more attention of researchers. Although this fusion method performs well in some cases, it still has some limitations, such as heavy computation and inconvenience for real-time use. In this work, we study map information of a given indoor environment, analyze variations of WiFi received signal strength (RSS), define several kinds of indoor landmarks, and then utilize these landmarks to correct accumulated errors derived from PDR. This fusion scheme, called Landmark-aided PDR (LaP), is proved to be light-weight and suitable for real-time implementation by running an Android application designed for the experiment. We compared LaP with other PDR-based fusion approaches. Experimental results show that the proposed scheme can achieve a significant improvement with an average accuracy of 2.17 m.

  14. An Indoor Positioning Method for Smartphones Using Landmarks and PDR †

    PubMed Central

    Wang, Xi; Jiang, Mingxing; Guo, Zhongwen; Hu, Naijun; Sun, Zhongwei; Liu, Jing

    2016-01-01

    Recently location based services (LBS) have become increasingly popular in indoor environments. Among these indoor positioning techniques providing LBS, a fusion approach combining WiFi-based and pedestrian dead reckoning (PDR) techniques is drawing more and more attention of researchers. Although this fusion method performs well in some cases, it still has some limitations, such as heavy computation and inconvenience for real-time use. In this work, we study map information of a given indoor environment, analyze variations of WiFi received signal strength (RSS), define several kinds of indoor landmarks, and then utilize these landmarks to correct accumulated errors derived from PDR. This fusion scheme, called Landmark-aided PDR (LaP), is proved to be light-weight and suitable for real-time implementation by running an Android application designed for the experiment. We compared LaP with other PDR-based fusion approaches. Experimental results show that the proposed scheme can achieve a significant improvement with an average accuracy of 2.17 m. PMID:27983670

  15. Automatic Construction of Wi-Fi Radio Map Using Smartphones

    NASA Astrophysics Data System (ADS)

    Liu, Tao; Li, Qingquan; Zhang, Xing

    2016-06-01

    Indoor positioning could provide interesting services and applications. As one of the most popular indoor positioning methods, location fingerprinting determines the location of mobile users by matching the received signal strength (RSS) which is location dependent. However, fingerprinting-based indoor positioning requires calibration and updating of the fingerprints which is labor-intensive and time-consuming. In this paper, we propose a visual-based approach for the construction of radio map for anonymous indoor environments without any prior knowledge. This approach collects multi-sensors data, e.g. video, accelerometer, gyroscope, Wi-Fi signals, etc., when people (with smartphones) walks freely in indoor environments. Then, it uses the multi-sensor data to restore the trajectories of people based on an integrated structure from motion (SFM) and image matching method, and finally estimates location of sampling points on the trajectories and construct Wi-Fi radio map. Experiment results show that the average location error of the fingerprints is about 0.53 m.

  16. Real-time indoor monitoring system based on wireless sensor networks

    NASA Astrophysics Data System (ADS)

    Wu, Zhengzhong; Liu, Zilin; Huang, Xiaowei; Liu, Jun

    2008-10-01

    Wireless sensor networks (WSN) greatly extend our ability to monitor and control the physical world. It can collaborate and aggregate a huge amount of sensed data to provide continuous and spatially dense observation of environment. The control and monitoring of indoor atmosphere conditions represents an important task with the aim of ensuring suitable working and living spaces to people. However, the comprehensive air quality, which includes monitoring of humidity, temperature, gas concentrations, etc., is not so easy to be monitored and controlled. In this paper an indoor WSN monitoring system was developed. In the system several sensors such as temperature sensor, humidity sensor, gases sensor, were built in a RF transceiver board for monitoring indoor environment conditions. The indoor environmental monitoring parameters can be transmitted by wireless to database server and then viewed throw PC or PDA accessed to the local area networks by administrators. The system, which was also field-tested and showed a reliable and robust characteristic, is significant and valuable to people.

  17. A hybrid stochastic approach for self-location of wireless sensors in indoor environments.

    PubMed

    Lloret, Jaime; Tomas, Jesus; Garcia, Miguel; Canovas, Alejandro

    2009-01-01

    Indoor location systems, especially those using wireless sensor networks, are used in many application areas. While the need for these systems is widely proven, there is a clear lack of accuracy. Many of the implemented applications have high errors in their location estimation because of the issues arising in the indoor environment. Two different approaches had been proposed using WLAN location systems: on the one hand, the so-called deductive methods take into account the physical properties of signal propagation. These systems require a propagation model, an environment map, and the position of the radio-stations. On the other hand, the so-called inductive methods require a previous training phase where the system learns the received signal strength (RSS) in each location. This phase can be very time consuming. This paper proposes a new stochastic approach which is based on a combination of deductive and inductive methods whereby wireless sensors could determine their positions using WLAN technology inside a floor of a building. Our goal is to reduce the training phase in an indoor environment, but, without an loss of precision. Finally, we compare the measurements taken using our proposed method in a real environment with the measurements taken by other developed systems. Comparisons between the proposed system and other hybrid methods are also provided.

  18. A Hybrid Stochastic Approach for Self-Location of Wireless Sensors in Indoor Environments

    PubMed Central

    Lloret, Jaime; Tomas, Jesus; Garcia, Miguel; Canovas, Alejandro

    2009-01-01

    Indoor location systems, especially those using wireless sensor networks, are used in many application areas. While the need for these systems is widely proven, there is a clear lack of accuracy. Many of the implemented applications have high errors in their location estimation because of the issues arising in the indoor environment. Two different approaches had been proposed using WLAN location systems: on the one hand, the so-called deductive methods take into account the physical properties of signal propagation. These systems require a propagation model, an environment map, and the position of the radio-stations. On the other hand, the so-called inductive methods require a previous training phase where the system learns the received signal strength (RSS) in each location. This phase can be very time consuming. This paper proposes a new stochastic approach which is based on a combination of deductive and inductive methods whereby wireless sensors could determine their positions using WLAN technology inside a floor of a building. Our goal is to reduce the training phase in an indoor environment, but, without an loss of precision. Finally, we compare the measurements taken using our proposed method in a real environment with the measurements taken by other developed systems. Comparisons between the proposed system and other hybrid methods are also provided. PMID:22412334

  19. ETS levels in hospitality environments satisfying ASHRAE standard 62-1989: "ventilation for acceptable indoor air quality"

    NASA Astrophysics Data System (ADS)

    Moschandreas, D. J.; Vuilleumier, K. L.

    Prior to this study, indoor air constituent levels and ventilation rates of hospitality environments had not been measured simultaneously. This investigation measured indoor Environmental Tobacco Smoke-related (ETS-related) constituent levels in two restaurants, a billiard hall and a casino. The objective of this study was to characterize ETS-related constituent levels inside hospitality environments when the ventilation rates satisfy the requirements of the ASHRAE 62-1989 Ventilation Standard. The ventilation rate of each selected hospitality environment was measured and adjusted. The study advanced only if the requirements of the ASHRAE 62-1989 Ventilation Standard - the pertinent standard of the American Society of Heating, Refrigeration and Air Conditioning Engineers - were satisfied. The supply rates of outdoor air and occupant density were measured intermittently to assure that the ventilation rate of each facility satisfied the standard under occupied conditions. Six ETS-related constituents were measured: respirable suspended particulate (RSP) matter, fluorescent particulate matter (FPM, an estimate of the ETS particle concentrations), ultraviolet particulate matter (UVPM, a second estimate of the ETS particle concentrations), solanesol, nicotine and 3-ethenylpyridine (3-EP). ETS-related constituent levels in smoking sections, non-smoking sections and outdoors were sampled daily for eight consecutive days at each hospitality environment. This study found that the difference between the concentrations of ETS-related constituents in indoor smoking and non-smoking sections was statistically significant. Differences between indoor non-smoking sections and outdoor ETS-related constituent levels were identified but were not statistically significant. Similarly, differences between weekday and weekend evenings were identified but were not statistically significant. The difference between indoor smoking sections and outdoors was statistically significant. Most importantly, ETS-related constituent concentrations measured indoors did not exceed existing occupational standards. It was concluded that if the measured ventilation rates of the sampled facilities satisfied the ASHRAE 62-1989 Ventilation Standard requirements, the corresponding ETS-related constituents were measured at concentrations below known harmful levels as specified by the American Conference of Governmental Industrial Hygiene (ACGIH).

  20. Indoor air quality of environments used for physical exercise and sports practice: Systematic review.

    PubMed

    Andrade, Alexandro; Dominski, Fábio Hech

    2018-01-15

    Systematic reviews have the potential to contribute substantially to environmental health and risk assessment. This study aimed to investigate indoor air quality of environments used for physical exercise and sports practice through a systematic review. The systematic review followed the PRISMA guidelines and was recorded in the PROSPERO registry (CRD42016036057). The search was performed using the SciELO, Science Direct, Scopus, LILACS, MEDLINE via PubMed, and SPORTDiscus databases, from their inception through April 2017. The search terms used in the databases were {air pollution" OR "air pollutants" OR "air quality"} AND {"physical exercise" OR "physical activity" OR "sport"}. The results of selected studies were divided into 5 categories for analysis: monitoring of air quality in the environment according to international guidelines, indoor-to-outdoor ratio (I/O), air quality during physical exercise, impact of air quality on health, and interventions to improve indoor air quality. Among 1281 studies screened, 34 satisfied the inclusion criteria. The monitoring of pollutants was conducted in 20 studies. CO and NO 2 were the most investigated pollutants, and guidelines were discussed in most studies. The I/O ratio was investigated in 12 studies, of which 9 showed a higher concentration of some pollutants in indoor rather than outdoor environments. Among the 34 studies selected, only 7 investigated the impact of indoor air pollution on human health. The population in most of these studies consisted of hockey players. Most studies conducted monitoring of pollutants in indoor environments used for physical exercise and sports practice. The earliest studies were conducted in ice skating rinks and the most recent evaluated gymnasiums, fitness centers, and sports centers. The CO, particulate matter, and NO 2 concentrations were the most investigated and have the longest history of investigation. These pollutants were within the limits established by guidelines in most studies. Studies that examined the association between air quality documented the adverse effects of pollution. There is a need for more studies focused on the relationship between pollution and health. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Spatial and temporal variations in indoor environmental conditions, human occupancy, and operational characteristics in a new hospital building

    DOE PAGES

    Ramos, Tiffanie; Dedesko, Sandra; Siegel, Jeffrey A.; ...

    2015-03-02

    The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogatemore » measures for human occupancy and activity in the patient rooms using both indoor air CO₂ concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ~8×10⁶ data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.« less

  2. Spatial and Temporal Variations in Indoor Environmental Conditions, Human Occupancy, and Operational Characteristics in a New Hospital Building

    PubMed Central

    Ramos, Tiffanie; Dedesko, Sandra; Siegel, Jeffrey A.; Gilbert, Jack A.; Stephens, Brent

    2015-01-01

    The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogate measures for human occupancy and activity in the patient rooms using both indoor air CO2 concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ∼8×106 data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections. PMID:25729898

  3. A Time-Aware Routing Map for Indoor Evacuation †

    PubMed Central

    Zhao, Haifeng; Winter, Stephan

    2016-01-01

    Knowledge of dynamic environments expires over time. Thus, using static maps of the environment for decision making is problematic, especially in emergency situations, such as evacuations. This paper suggests a fading memory model for mapping dynamic environments: a mechanism to put less trust on older knowledge in decision making. The model has been assessed by simulating indoor evacuations, adopting and comparing various strategies in decision making. Results suggest that fading memory generally improves this decision making. PMID:26797610

  4. Implementing Green Walls in Schools.

    PubMed

    McCullough, Michael B; Martin, Michael D; Sajady, Mollika A

    2018-01-01

    Numerous studies in applied pedagogical design have shown that, at all educational levels, direct exposure to the natural environment can enhance learning by improving student attention and behaviors. Implementing green walls-a "vertical garden," or "living wall" interior wall that typically includes greenery, a growing medium (soil or substrate) and a water delivery system-provides environmental health benefits, but also provides a practical application within classrooms for minimizing directed attention fatigue in students by connecting them to "outdoor nature" within the indoor environment. Hands-on "project-based" learning is another pedagogical strategy that has proved to be effective across the spectrum of educational levels and across subject areas. Green walls have the potential to inspire critical thinking through a combination of project-based learning strategies and environmental education. The authors have outlined a curriculum involving the implementation of an indoor living wall system within a classroom-learning environment, incorporating project-based learning modules that interact with the wall. In conjunction with the passive health benefits of a green wall, project-based curriculum models can connect students interactively with indoor nature and have the potential to inspire real-world thinking related to science, technology, engineering, art, and mathematics fields within the indoor learning environment. Through a combination of these passive and interactive modes, students are connected to nature in the indoor environment regardless of weather conditions outdoors. Future research direction could include post-construction studies of the effectiveness of project-based curricula related to living walls, and the long-term impacts of implementing green walls in classrooms on school achievement and student behaviors.

  5. 40 CFR 35.298 - Award limitations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... STATE AND LOCAL ASSISTANCE Environmental Program Grants State Indoor Radon Grants (section 306) § 35.298 Award limitations. (a) The Regional Administrator shall not include State Indoor Radon funds in a... has the primary responsibility for radon programs as designated by the Governor of the affected State...

  6. The indoor-outdoor characteristics of water-soluble ion in PM2.5 in Tianjin wintertime.

    PubMed

    Wang, Baoqing; Niu, Honghong; Liu, Bowei; Hu, Xinxin; Ren, Zihui

    2018-05-15

    The indoor and outdoor PM 2.5 mass concentration, water-soluble ion by filter sampler was analyzed on December 3-21, 2015 during wintertime in Tianjin, China. The results indicate that high humidity conditions result in the accumulation of atmospheric pollutants and reduce atmosphere visibility. The I/O ratio for PM 2.5 concentration in dormitory and lab are less than 1 in haze days. Indoor PM 2.5 concentration increases rapidly with outdoor PM 2.5 concentration increasing in haze days. The filtration factors of the dormitory and lab indicate nearly half of the outdoor PM 2.5 enters indoor environment. The human activities in dormitory could cause more the formation of PM 2.5 than those in lab. The concentration of SO 4 2- is the highest ion in water-soluble ion for outdoor PM 2.5 . The SO 4 2- , NO 3 - , NH 4 + , and Cl - are generated mainly by outdoor sources; however, the Na + , Ca 2+ , and Mg 2+ are generated mainly by indoor sources. The NH 4 NO 3 , (NH 4 ) 2 SO 4 , and NH 4 Cl accounts for 20.2~41.8%, 32.0~51.4%, and 6.4~10.6% of the total water-soluble ion in different indoor-outdoor environment. The total secondary aerosols including NH 4 NO 3 , (NH 4 ) 2 SO 4 , and NH 4 Cl in PM 2.5 are 28.3, 42.1, 28.2, 31.0, and 33.9% in outdoor environment for haze days, outdoor environment for non-haze days, dormitory for haze days, dormitory for non-haze days, and lab for haze days, respectively.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramos, Tiffanie; Dedesko, Sandra; Siegel, Jeffrey A.

    The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogatemore » measures for human occupancy and activity in the patient rooms using both indoor air CO₂ concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ~8×10⁶ data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.« less

  8. Developing Decontamination Tools and Approaches to ...

    EPA Pesticide Factsheets

    Developing Decontamination Tools and Approaches to Address Indoor Pesticide Contamination from Improper Bed Bug Treatments The National Exposure Research Laboratory (NERL) Human Exposure and Atmospheric Sciences Division (HEASD) conducts research in support of EPA mission to protect human health and the environment. HEASD research program supports Goal 1 (Clean Air) and Goal 4 (Healthy People) of EPA strategic plan. More specifically, our division conducts research to characterize the movement of pollutants from the source to contact with humans. Our multidisciplinary research program produces Methods, Measurements, and Models to identify relationships between and characterize processes that link source emissions, environmental concentrations, human exposures, and target-tissue dose. The impact of these tools is improved regulatory programs and policies for EPA.

  9. Human Occupancy as a Source of Indoor Airborne Bacteria

    PubMed Central

    Hospodsky, Denina; Qian, Jing; Nazaroff, William W.; Yamamoto, Naomichi; Bibby, Kyle; Rismani-Yazdi, Hamid; Peccia, Jordan

    2012-01-01

    Exposure to specific airborne bacteria indoors is linked to infectious and noninfectious adverse health outcomes. However, the sources and origins of bacteria suspended in indoor air are not well understood. This study presents evidence for elevated concentrations of indoor airborne bacteria due to human occupancy, and investigates the sources of these bacteria. Samples were collected in a university classroom while occupied and when vacant. The total particle mass concentration, bacterial genome concentration, and bacterial phylogenetic populations were characterized in indoor, outdoor, and ventilation duct supply air, as well as in the dust of ventilation system filters and in floor dust. Occupancy increased the total aerosol mass and bacterial genome concentration in indoor air PM10 and PM2.5 size fractions, with an increase of nearly two orders of magnitude in airborne bacterial genome concentration in PM10. On a per mass basis, floor dust was enriched in bacterial genomes compared to airborne particles. Quantitative comparisons between bacterial populations in indoor air and potential sources suggest that resuspended floor dust is an important contributor to bacterial aerosol populations during occupancy. Experiments that controlled for resuspension from the floor implies that direct human shedding may also significantly impact the concentration of indoor airborne particles. The high content of bacteria specific to the skin, nostrils, and hair of humans found in indoor air and in floor dust indicates that floors are an important reservoir of human-associated bacteria, and that the direct particle shedding of desquamated skin cells and their subsequent resuspension strongly influenced the airborne bacteria population structure in this human-occupied environment. Inhalation exposure to microbes shed by other current or previous human occupants may occur in communal indoor environments. PMID:22529946

  10. Moldy buildings, health of their occupants and fungal prevention.

    PubMed

    Mihinova, D; Pieckova, E

    2012-01-01

    Microscopic fungi are important biological pollutants in the indoor environment, they are spread generally: on building materials, carpets, ceiling tiles, insulations, any surfaces, wallpapers, or in heating, ventilation, and air conditioning systems. Molds are able to grow on any materials, as long as moisture and oxygen are available. Exposure to fungi in indoor environments (esp. in water-damaged buildings) can cause adverse health effects, such as allergy, asthma, hypersensitivity pneumonia, mucous membrane irritation, different toxic effects, or even mycoses (in immunocompromised individuals) - alone or in combination. As serious adverse health effects could be caused antifungal prevention is an absolute need.This review article summarizes the occurrence of fungi in the indoor environment of buildings and their contribution to occupants´ health problems, and preventive measures against molds (Tab. 1, Fig. 1, Ref. 48).

  11. Indoor Semi-volatile Organic Compounds (i-SVOC) Version 1.0

    EPA Pesticide Factsheets

    i-SVOC Version 1.0 is a general-purpose software application for dynamic modeling of the emission, transport, sorption, and distribution of semi-volatile organic compounds (SVOCs) in indoor environments.

  12. 75 FR 68784 - Healthy Indoor Environment Protocols for Home Energy Upgrades

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-09

    ... Home Energy Upgrades, in conjunction with the availability of the Department of Energy (DOE) Workforce... also provide the specific responses necessary to maintain or improve indoor air quality in conjunction...

  13. The relationship between thermal environments and clothing insulation for elderly individuals in Shanghai, China.

    PubMed

    Jiao, Yu; Yu, Hang; Wang, Tian; An, Yusong; Yu, Yifan

    2017-12-01

    The relationship between thermal environmental parameters and clothing insulation is an important element in improving thermal comfort for the elderly. A field study was conducted on the indoor, transition space, and outdoor thermal environments of 17 elderly facilities in Shanghai, China. A random questionnaire survey was used to gather data from 672 valid samples. A statistical analysis of the data was conducted, and multiple linear regression models were established to quantify the relationships between clothing insulation, respondent age, indoor air temperature, and indoor relative humidity. Results indicated that the average thermal insulation of winter and summer clothing is 1.38 clo and 0.44 clo, respectively, for elderly men and 1.39 clo and 0.45 clo, respectively, for elderly women. It was also found that the thermal insulation of winter clothing is linearly correlated with age, and that there were seasonal differences in the relationship between clothing insulation and the environment. During winter, the clothing insulation is negatively correlated only with indoor temperature parameters (air temperature and operative temperature) for elderly males, while it is negatively correlated with indoor temperature parameters as well as transition space and outdoor air temperature for elderly females. In summer, clothing insulation for both elderly males and females is negatively correlated with outdoor temperature, as well as indoor temperature parameters (air temperature and operative temperature). The thermal insulation of summer clothing is also negatively correlated with transitional space temperature for males. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Indoor Localization Using Wi-Fi Based Fingerprinting and Trilateration Techiques for Lbs Applications

    NASA Astrophysics Data System (ADS)

    Chan, S.; Sohn, G.

    2012-06-01

    The past few years have seen wide spread adoption of outdoor positioning services, mainly GPS, being incorporated into everyday devices such as smartphones and tablets. While outdoor positioning has been well received by the public, its indoor counterpart has been mostly limited to private use due to its higher costs and complexity for setting up the proper environment. The objective of this research is to provide an affordable mean for indoor localization using wireless local area network (WLAN) Wi-Fi technology. We combined two different Wi-Fi approaches to locate a user. The first method involves the use of matching the pre-recorded received signal strength (RSS) from nearby access points (AP), to the data transmitted from the user on the fly. This is commonly known as "fingerprint matching". The second approach is a distance-based trilateration approach using three known AP coordinates detected on the user's device to derive the position. The combination of the two steps enhances the accuracy of the user position in an indoor environment allowing location-based services (LBS) such as mobile augmented reality (MAR) to be deployed more effectively in the indoor environment. The mapping of the RSS map can also prove useful to IT planning personnel for covering locations with no Wi-Fi coverage (ie. dead spots). The experiments presented in this research helps provide a foundation for the integration of indoor with outdoor positioning to create a seamless transition experience for users.

  15. Light use efficiency for vegetables production in protected and indoor environments

    NASA Astrophysics Data System (ADS)

    Cocetta, Giacomo; Casciani, Daria; Bulgari, Roberta; Musante, Fulvio; Kołton, Anna; Rossi, Maurizio; Ferrante, Antonio

    2017-01-01

    In recent years, there is a growing interest for vegetables production in indoor or disadvantaged climatic zones by using greenhouses. The main problem of crop growing indoor or in environment with limited light availability is the correct choice of light source and the quality of lighting spectrum. In greenhouse and indoor cultivations, plant density is higher than in the open field and plants have to compete for light and nutrients. Nowadays, advanced systems for indoor horticulture use light emitting diodes (LED) for improving crop growth, enhancing the plant productivity and favouring the best nutritional quality formation. In closed environments, as indoor growing modules, the lighting system represents the only source of light and its features are fundamental for obtaining the best lighting performances for plant and the most efficient solution. LED lighting engines are more efficient compared to the lighting sources used traditionally in horticulture and allow light spectrum and intensity modulations to enhance the light use efficiency for plants. The lighting distribution and the digital controls are fundamental for tailoring the spectral distribution on each plant in specific moments of its growth and play an important role for optimizing growth and produce high-quality vegetables. LED lights can increase plant growth and yield, but also nutraceutical quality, since some light intensities increase pigments biosynthesis and enhance the antioxidants content of leaves or fruits: in this regards the selection of LED primary light sources in relation to the peaks of the absorbance curve of the plants is important.

  16. An overview of indoor air quality and its impact on respiratory health among Malaysian school-aged children.

    PubMed

    Choo, Chua Poh; Jalaludin, Juliana

    2015-01-01

    The indoor environment is a major source of human exposure to pollutants. Some pollutants can have concentrations that are several times higher indoors than outdoors. Prolonged exposure may lead to adverse biologic effects, even at low concentrations. Several studies done in Malaysia had underlined the role of indoor air pollution in affecting respiratory health, especially for school-aged children. A critical review was conducted on the quantitative literature linking indoor air pollution with respiratory illnesses among school-aged children. This paper reviews evidence of the association between indoor air quality (IAQ) and its implications on respiratory health among Malaysian school-aged children. This review summarizes six relevant studies conducted in Malaysia for the past 10 years. Previous epidemiologic studies relevant to indoor air pollutants and their implications on school-aged children's respiratory health were obtained from electronic database and included as a reference in this review. The existing reviewed data emphasize the impact of IAQ parameters, namely, indoor temperature, ventilation rates, indoor concentration of carbon dioxide (CO2), carbon monoxide (CO), particulate matters (PM), volatile organic compounds (VOCs), nitrogen dioxide (NO2) and airborne microbes, on children's respiratory health. The study found that most of the Malaysian school-aged children are exposed to the inadequate environment during their times spent either in their houses or in their classrooms, which is not in compliance with the established standards. Children living in households or studying in schools in urban areas are more likely to suffer from respiratory illnesses compared with children living in homes or studying in schools in rural areas.

  17. VOC source identification from personal and residential indoor, outdoor and workplace microenvironment samples in EXPOLIS-Helsinki, Finland

    NASA Astrophysics Data System (ADS)

    Edwards, Rufus D.; Jurvelin, J.; Koistinen, K.; Saarela, K.; Jantunen, M.

    Principal component analyses (varimax rotation) were used to identify common sources of 30 target volatile organic compounds (VOCs) in residential outdoor, residential indoor and workplace microenvironment and personal 48-h exposure samples, as a component of the EXPOLIS-Helsinki study. Variability in VOC concentrations in residential outdoor microenvironments was dominated by compounds associated with long-range transport of pollutants, followed by traffic emissions, emissions from trees and product emissions. Variability in VOC concentrations in environmental tobacco smoke (ETS) free residential indoor environments was dominated by compounds associated with indoor cleaning products, followed by compounds associated with traffic emissions, long-range transport of pollutants and product emissions. Median indoor/outdoor ratios for compounds typically associated with traffic emissions and long-range transport of pollutants exceeded 1, in some cases quite considerably, indicating substantial indoor source contributions. Changes in the median indoor/outdoor ratios during different seasons reflected different seasonal ventilation patterns as increased ventilation led to dilution of those VOC compounds in the indoor environment that had indoor sources. Variability in workplace VOC concentrations was dominated by compounds associated with traffic emissions followed by product emissions, long-range transport and air fresheners. Variability in VOC concentrations in ETS free personal exposure samples was dominated by compounds associated with traffic emissions, followed by long-range transport, cleaning products and product emissions. VOC sources in personal exposure samples reflected the times spent in different microenvironments, and personal exposure samples were not adequately represented by any one microenvironment, demonstrating the need for personal exposure sampling.

  18. CATALOG OF MATERIALS AS POTENTIAL SOURCES OF INDOOR AIR EMISSIONS - VOLUME 1. INSULATION, WALLCOVERINGS, RESILIENT FLOOR COVERINGS, CARPET, ADHESIVES, SEALANTS AND CAULKS, AND PESTICIDES

    EPA Science Inventory

    The report discusses and presents data on constituents and emissions from products that have the potential to impact the indoor air environment. t is a tool to be used by researchers to help organize the study of materials as potential sources of indoor air emissions. ncluded are...

  19. National Academy of Sciences (NAS) Study entitled The Effect of Climate Change on Indoor Air Quality and Public Health.

    EPA Science Inventory

    The Institute of Medicine of the NAS is conducting a study to evaluate the state of scientific understanding of the effects of climate change on indoor air quality and public health. General topics may include the likely impacts of climate change in the U.S. on the indoor environ...

  20. Effects of indoor air purification by an air cleaning system (Koala technology) on semen parameters in male factor infertility: results of a pilot study.

    PubMed

    Paradisi, R; Vanella, S; Barzanti, R; Cani, C; Battaglia, C; Seracchioli, R; Venturoli, S

    2009-06-01

    A number of studies indicated a clear decline in semen quality in the past 30-50 years and there is accumulating evidence that this decline might result from exposure to high levels of air pollution. To examine the impact of environment on male reproductive ability, we undertook for the first time a pilot study on semen quality of infertile men exposed to purification of indoor air. Ten subjects with a history of unexplained male infertility and poor semen quality were exposed for at least 1 year to a cleaning indoor air system (Koala technology). The key feature of this air purifier is the unique innovative multiple filtering system. The treatment of total purification of indoor air showed neither improvements in semen parameters nor variation in reproductive hormones (P = N.S.), but induced an evident increase (P < 0.03 and more) in seminal leucocytic concentrations. Within the limits due to the small sample of subjects recruited, the sole purification of indoor air does not seem enough to improve semen quality, although the increase in leucocytic concentrations could indicate an activation of the role of immunosurveillance in a purified indoor air environment.

  1. 3D modeling of building indoor spaces and closed doors from imagery and point clouds.

    PubMed

    Díaz-Vilariño, Lucía; Khoshelham, Kourosh; Martínez-Sánchez, Joaquín; Arias, Pedro

    2015-02-03

    3D models of indoor environments are increasingly gaining importance due to the wide range of applications to which they can be subjected: from redesign and visualization to monitoring and simulation. These models usually exist only for newly constructed buildings; therefore, the development of automatic approaches for reconstructing 3D indoors from imagery and/or point clouds can make the process easier, faster and cheaper. Among the constructive elements defining a building interior, doors are very common elements and their detection can be very useful either for knowing the environment structure, to perform an efficient navigation or to plan appropriate evacuation routes. The fact that doors are topologically connected to walls by being coplanar, together with the unavoidable presence of clutter and occlusions indoors, increases the inherent complexity of the automation of the recognition process. In this work, we present a pipeline of techniques used for the reconstruction and interpretation of building interiors based on point clouds and images. The methodology analyses the visibility problem of indoor environments and goes in depth with door candidate detection. The presented approach is tested in real data sets showing its potential with a high door detection rate and applicability for robust and efficient envelope reconstruction.

  2. Indoor pollutants emitted by office equipment: A review ofreported data and information needs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Destaillats, Hugo; Maddalena, Randy L.; Singer, Brett C.

    2007-02-01

    There is concern that potentially harmful pollutants may be emitted from office equipment. Although office equipment has been a focal point for governmental efforts to promote energy efficiency through programs such as the US EPA's Energy Star, little is known about the relationship between office equipment use and indoor air quality, and information on pollutant emissions is sparse. In this review, we summarize available information on emission rates and/or ambient concentrations of various pollutants that are related to office equipment use. Experimental methods used in the characterization of emissions are briefly described. The office equipment evaluated in this review includesmore » computers (desktops and notebooks), printers (laser, ink-jet and all-in-one machines) and photocopy machines. Reported emission rates of the following pollutant groups are summarized: volatile organic chemicals (VOCs), ozone, particulate matter and several semivolatile organic chemicals (SVOCs). The latter include phthalate esters, brominated flame retardants, organophosphate flame retardants and polycyclic aromatic hydrocarbons (PAHs). We also review studies reporting airborne concentrations in indoor environments where office equipment was present and thought to be a significant contributor to the total pollutant burden (offices, residences, schools, electronics recycling plants). For certain pollutants, such as organophosphate flame retardants, the link between emission by office equipment and indoor air concentrations is relatively well established. However, indoor VOCs, ozone, PAHs and phthalate esters can originate from a variety of sources, and their source apportionment is less straightforward. This literature review identifies substances of toxicological significance, with the purpose of serving as a guide to evaluate their potential importance with respect to human exposures.« less

  3. Influences of Green Outdoors versus Indoors Environmental Settings on Psychological and Social Outcomes of Controlled Exercise

    PubMed Central

    Rogerson, Mike; Gladwell, Valerie F.; Gallagher, Daniel J.; Barton, Jo L.

    2016-01-01

    This study addressed a methodological gap by comparing psychological and social outcomes of exercise in green outdoors versus built indoors settings, whilst rigorously controlling exercise mode and intensity. The hypotheses were that greater improvements or more desirable values for directed attention, mood, perceived exertion, social interaction time, intention for future exercise behaviour and enjoyment would be associated with outdoors compared to indoors exercise. Following a baseline session, paired participants completed two conditions of 15 min of cycling on an ergometer placed outside in a natural environment and inside in a laboratory setting in a randomized, counter-balanced order. At pre- and post-exercise, directed attention was measured with the digit span backwards task, and mood was assessed with the Profile of Mood States. During the exercise session, visual and verbal interactions were recorded by means of experimenter observations. After each exercise session, participants provided self-reports of their enjoyment of the exercise, perceived exertion and intention for future exercise in the same environment. Social interaction time was significantly greater during outdoors exercise versus indoors; on average, participants engaged in three minutes more social interaction during exercise outdoors compared to indoors. Social interaction time significantly predicted intention for future exercise in the outdoors condition, but did not in the indoor condition. There was a significant time by condition interaction for directed attention. Scores worsened in the indoors condition, but improved in the outdoors condition. There was no statistically-significant time by condition interaction for mood and no significant difference between conditions for either perceived exertion or intention. Taken together, these findings show that exercise in a natural environment may promote directed attention and social interactions, which may positively influence future exercise intentions. PMID:27023580

  4. Indirect health effects of relative humidity in indoor environments.

    PubMed Central

    Arundel, A V; Sterling, E M; Biggin, J H; Sterling, T D

    1986-01-01

    A review of the health effects of relative humidity in indoor environments suggests that relative humidity can affect the incidence of respiratory infections and allergies. Experimental studies on airborne-transmitted infectious bacteria and viruses have shown that the survival or infectivity of these organisms is minimized by exposure to relative humidities between 40 and 70%. Nine epidemiological studies examined the relationship between the number of respiratory infections or absenteeism and the relative humidity of the office, residence, or school. The incidence of absenteeism or respiratory infections was found to be lower among people working or living in environments with mid-range versus low or high relative humidities. The indoor size of allergenic mite and fungal populations is directly dependent upon the relative humidity. Mite populations are minimized when the relative humidity is below 50% and reach a maximum size at 80% relative humidity. Most species of fungi cannot grow unless the relative humidity exceeds 60%. Relative humidity also affects the rate of offgassing of formaldehyde from indoor building materials, the rate of formation of acids and salts from sulfur and nitrogen dioxide, and the rate of formation of ozone. The influence of relative humidity on the abundance of allergens, pathogens, and noxious chemicals suggests that indoor relative humidity levels should be considered as a factor of indoor air quality. The majority of adverse health effects caused by relative humidity would be minimized by maintaining indoor levels between 40 and 60%. This would require humidification during winter in areas with cold winter climates. Humidification should preferably use evaporative or steam humidifiers, as cool mist humidifiers can disseminate aerosols contaminated with allergens. PMID:3709462

  5. Influences of Green Outdoors versus Indoors Environmental Settings on Psychological and Social Outcomes of Controlled Exercise.

    PubMed

    Rogerson, Mike; Gladwell, Valerie F; Gallagher, Daniel J; Barton, Jo L

    2016-03-25

    This study addressed a methodological gap by comparing psychological and social outcomes of exercise in green outdoors versus built indoors settings, whilst rigorously controlling exercise mode and intensity. The hypotheses were that greater improvements or more desirable values for directed attention, mood, perceived exertion, social interaction time, intention for future exercise behaviour and enjoyment would be associated with outdoors compared to indoors exercise. Following a baseline session, paired participants completed two conditions of 15 min of cycling on an ergometer placed outside in a natural environment and inside in a laboratory setting in a randomized, counter-balanced order. At pre- and post-exercise, directed attention was measured with the digit span backwards task, and mood was assessed with the Profile of Mood States. During the exercise session, visual and verbal interactions were recorded by means of experimenter observations. After each exercise session, participants provided self-reports of their enjoyment of the exercise, perceived exertion and intention for future exercise in the same environment. Social interaction time was significantly greater during outdoors exercise versus indoors; on average, participants engaged in three minutes more social interaction during exercise outdoors compared to indoors. Social interaction time significantly predicted intention for future exercise in the outdoors condition, but did not in the indoor condition. There was a significant time by condition interaction for directed attention. Scores worsened in the indoors condition, but improved in the outdoors condition. There was no statistically-significant time by condition interaction for mood and no significant difference between conditions for either perceived exertion or intention. Taken together, these findings show that exercise in a natural environment may promote directed attention and social interactions, which may positively influence future exercise intentions.

  6. Bim-Based Indoor Path Planning Considering Obstacles

    NASA Astrophysics Data System (ADS)

    Xu, M.; Wei, S.; Zlatanova, S.; Zhang, R.

    2017-09-01

    At present, 87 % of people's activities are in indoor environment; indoor navigation has become a research issue. As the building structures for people's daily life are more and more complex, many obstacles influence humans' moving. Therefore it is essential to provide an accurate and efficient indoor path planning. Nowadays there are many challenges and problems in indoor navigation. Most existing path planning approaches are based on 2D plans, pay more attention to the geometric configuration of indoor space, often ignore rich semantic information of building components, and mostly consider simple indoor layout without taking into account the furniture. Addressing the above shortcomings, this paper uses BIM (IFC) as the input data and concentrates on indoor navigation considering obstacles in the multi-floor buildings. After geometric and semantic information are extracted, 2D and 3D space subdivision methods are adopted to build the indoor navigation network and to realize a path planning that avoids obstacles. The 3D space subdivision is based on triangular prism. The two approaches are verified by the experiments.

  7. 40 CFR 35.702 - Basis for allotment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... STATE AND LOCAL ASSISTANCE Environmental Program Grants for Tribes Indoor Radon Grants (section 306) § 35.702 Basis for allotment. (a) The Regional Administrator will allot Indoor Radon Grant funds based... Control Act. (b) No Tribe or Intertribal Consortium may receive an Indoor Radon Grant in excess of 10...

  8. 40 CFR 35.292 - Basis for allotment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... STATE AND LOCAL ASSISTANCE Environmental Program Grants State Indoor Radon Grants (section 306) § 35.292 Basis for allotment. (a) The Regional Administrator will allot State Indoor Radon Grant funds based on... Control Act. (b) No State may receive a State Indoor Radon Grant in excess of 10 percent of the total...

  9. SIMULATION TOOL KIT FOR INDOOR AIR QUALITY AND INHALATION EXPOSURE (IAQX) VERSION 1.0 USER'S GUIDE

    EPA Science Inventory

    The User's Guide describes a Microsoft Windows-based indoor air quality (IAQ) simulation software package designed Simulation Tool Kit for Indoor Air Quality and Inhalation Exposure, or IAQX for short. This software complements and supplements existing IAQ simulation programs and...

  10. Indoor Air Quality: Maryland Public Schools.

    ERIC Educational Resources Information Center

    Maryland State Dept. of Education, College Park. Office of Administration and Finance.

    Less than adequate indoor air quality in schools can lead to a higher risk of health problems, an increase in student and teacher absenteeism, diminished learning, and even hazardous conditions. An indoor air quality program that addresses the planning, design, maintenance, and operation of public school buildings should be implemented at the…

  11. 40 CFR 35.292 - Basis for allotment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... STATE AND LOCAL ASSISTANCE Environmental Program Grants State Indoor Radon Grants (section 306) § 35.292 Basis for allotment. (a) The Regional Administrator will allot State Indoor Radon Grant funds based on... Control Act. (b) No State may receive a State Indoor Radon Grant in excess of 10 percent of the total...

  12. 40 CFR 35.702 - Basis for allotment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... STATE AND LOCAL ASSISTANCE Environmental Program Grants for Tribes Indoor Radon Grants (section 306) § 35.702 Basis for allotment. (a) The Regional Administrator will allot Indoor Radon Grant funds based... Control Act. (b) No Tribe or Intertribal Consortium may receive an Indoor Radon Grant in excess of 10...

  13. A Hybrid 3D Indoor Space Model

    NASA Astrophysics Data System (ADS)

    Jamali, Ali; Rahman, Alias Abdul; Boguslawski, Pawel

    2016-10-01

    GIS integrates spatial information and spatial analysis. An important example of such integration is for emergency response which requires route planning inside and outside of a building. Route planning requires detailed information related to indoor and outdoor environment. Indoor navigation network models including Geometric Network Model (GNM), Navigable Space Model, sub-division model and regular-grid model lack indoor data sources and abstraction methods. In this paper, a hybrid indoor space model is proposed. In the proposed method, 3D modeling of indoor navigation network is based on surveying control points and it is less dependent on the 3D geometrical building model. This research proposes a method of indoor space modeling for the buildings which do not have proper 2D/3D geometrical models or they lack semantic or topological information. The proposed hybrid model consists of topological, geometrical and semantical space.

  14. Hygrothermal Analysis of Indoor Environment of Residential Prefabricated Buildings

    NASA Astrophysics Data System (ADS)

    Kraus, Michal

    2017-10-01

    Recent studies show that the relative humidity and the indoor air temperature constitute an important determinant of the quality of indoor air. Hygrothermal microclimate has a significant impact on occupant’s health and their comfort. The study presents the results of experimental measurement of indoor air temperature and relative humidity in selected apartment in prefabricated panel house situated in Ostrava, Czechia. The contribution describes and analysis the relation between indoor air temperature [°C] and relative humidity [%] in this apartment. The experimental object is selected with respect to the housing stock in the Czech Republic. A third of the housing stock in the Czech Republic is composed of prefabricated panel houses. Regeneration and revitalization of these buildings were in the focus of interest during recent years. Building modifications, such as thermal insulation of building envelope or window replacement, lead to a significantly higher level of airtightness of these objects. Humidity and indoor air temperature are measured in 10-minute cycles for two periods. The values of temperature and humidity are measured for the non-heating and the heating season. The length of each experimental period is 30 days. The mean value of indoor air temperature is 22.21 °C and average relative humidity is 45.87% in the non-heating period. The values of 22.62 °C and 35.20% represent average values for the heating period. A slight increase of the average temperature of the indoor environment (+1.85%) is observed. The decrease of the relative humidity is evident at first glance. The relative humidity of the internal environment is approximately 10% lower in the heating period. Long-term decline of relative humidity below 30% brings many problems. It is necessary to take measures to increase of relative humidity in residential prefabricated building. The aquarium appears to be ineffective. The solution may be forced artificial ventilation or humidifiers.

  15. A model to estimate the cost effectiveness of the indoorenvironment improvements in office work

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seppanen, Olli; Fisk, William J.

    2004-06-01

    Deteriorated indoor climate is commonly related to increases in sick building syndrome symptoms, respiratory illnesses, sick leave, reduced comfort and losses in productivity. The cost of deteriorated indoor climate for the society is high. Some calculations show that the cost is higher than the heating energy costs of the same buildings. Also building-level calculations have shown that many measures taken to improve indoor air quality and climate are cost-effective when the potential monetary savings resulting from an improved indoor climate are included as benefits gained. As an initial step towards systemizing these building level calculations we have developed a conceptualmore » model to estimate the cost-effectiveness of various measures. The model shows the links between the improvements in the indoor environment and the following potential financial benefits: reduced medical care cost, reduced sick leave, better performance of work, lower turn over of employees, and lower cost of building maintenance due to fewer complaints about indoor air quality and climate. The pathways to these potential benefits from changes in building technology and practices go via several human responses to the indoor environment such as infectious diseases, allergies and asthma, sick building syndrome symptoms, perceived air quality, and thermal environment. The model also includes the annual cost of investments, operation costs, and cost savings of improved indoor climate. The conceptual model illustrates how various factors are linked to each other. SBS symptoms are probably the most commonly assessed health responses in IEQ studies and have been linked to several characteristics of buildings and IEQ. While the available evidence indicates that SBS symptoms can affect these outcomes and suspects that such a linkage exists, at present we can not quantify the relationships sufficiently for cost-benefit modeling. New research and analyses of existing data to quantify the financial importance of SBS symptoms would enable more widespread consideration of the effects of IEQ in cost benefit calculations.« less

  16. Healthy Learning.

    ERIC Educational Resources Information Center

    Kennedy, Mike

    2003-01-01

    Offers ten suggestions for schools and universities to help maintain a healthy indoor environment: proper flooring, sanitary washrooms, consistent maintenance, indoor air quality, preventing mold, daylighting, good acoustics, avoiding volatile organic compounds (VOCs), ergonomic furniture, and well-maintained roofs. (EV)

  17. Indoor Air Pollution (Environmental Health Student Portal)

    MedlinePlus

    ... on how indoor and outdoor air pollution affects human health. Healthy Air at Home (American Lung Association) - Resources ... and the environment, and the potential risks to human health. Experiments and Projects Air Quality (PDF, 981.40 ...

  18. 40 CFR 35.703 - Eligible recipients.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... STATE AND LOCAL ASSISTANCE Environmental Program Grants for Tribes Indoor Radon Grants (section 306... Consortium as eligible to apply for an Indoor Radon Grant if the Tribe or each member of the Intertribal... that information unique to the radon grant program required by paragraphs (a)(3) and (4) of this...

  19. 40 CFR 35.703 - Eligible recipients.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... STATE AND LOCAL ASSISTANCE Environmental Program Grants for Tribes Indoor Radon Grants (section 306... Consortium as eligible to apply for an Indoor Radon Grant if the Tribe or each member of the Intertribal... that information unique to the radon grant program required by paragraphs (a)(3) and (4) of this...

  20. Space for Learning: A Pre-School Environment for Very Little Money.

    ERIC Educational Resources Information Center

    1972

    This booklet identifies environments for pre-school learning. Each page may serve as a poster, a reminder of activities, or as a starting point for a training session. It includes an indoor and an outdoor section. The indoor section describes an art area, a music area, and a quiet area, a housekeeping area, free space for floor play, and a science…

  1. Passive Infrared (PIR)-Based Indoor Position Tracking for Smart Homes Using Accessibility Maps and A-Star Algorithm.

    PubMed

    Yang, Dan; Xu, Bin; Rao, Kaiyou; Sheng, Weihua

    2018-01-24

    Indoor occupants' positions are significant for smart home service systems, which usually consist of robot service(s), appliance control and other intelligent applications. In this paper, an innovative localization method is proposed for tracking humans' position in indoor environments based on passive infrared (PIR) sensors using an accessibility map and an A-star algorithm, aiming at providing intelligent services. First the accessibility map reflecting the visiting habits of the occupants is established through the integral training with indoor environments and other prior knowledge. Then the PIR sensors, which placement depends on the training results in the accessibility map, get the rough location information. For more precise positioning, the A-start algorithm is used to refine the localization, fused with the accessibility map and the PIR sensor data. Experiments were conducted in a mock apartment testbed. The ground truth data was obtained from an Opti-track system. The results demonstrate that the proposed method is able to track persons in a smart home environment and provide a solution for home robot localization.

  2. Modelling of Indoor Environments Using Lindenmayer Systems

    NASA Astrophysics Data System (ADS)

    Peter, M.

    2017-09-01

    Documentation of the "as-built" state of building interiors has gained a lot of interest in the recent years. Various data acquisition methods exist, e.g. the extraction from photographed evacuation plans using image processing or, most prominently, indoor mobile laser scanning. Due to clutter or data gaps as well as errors during data acquisition and processing, automatic reconstruction of CAD/BIM-like models from these data sources is not a trivial task. Thus it is often tried to support reconstruction by general rules for the perpendicularity and parallelism which are predominant in man-made structures. Indoor environments of large, public buildings, however, often also follow higher-level rules like symmetry and repetition of e.g. room sizes and corridor widths. In the context of reconstruction of city city elements (e.g. street networks) or building elements (e.g. façade layouts), formal grammars have been put to use. In this paper, we describe the use of Lindenmayer systems - which originally have been developed for the computer-based modelling of plant growth - to model and reproduce the layout of indoor environments in 2D.

  3. Passive Infrared (PIR)-Based Indoor Position Tracking for Smart Homes Using Accessibility Maps and A-Star Algorithm

    PubMed Central

    Yang, Dan; Xu, Bin; Rao, Kaiyou; Sheng, Weihua

    2018-01-01

    Indoor occupants’ positions are significant for smart home service systems, which usually consist of robot service(s), appliance control and other intelligent applications. In this paper, an innovative localization method is proposed for tracking humans’ position in indoor environments based on passive infrared (PIR) sensors using an accessibility map and an A-star algorithm, aiming at providing intelligent services. First the accessibility map reflecting the visiting habits of the occupants is established through the integral training with indoor environments and other prior knowledge. Then the PIR sensors, which placement depends on the training results in the accessibility map, get the rough location information. For more precise positioning, the A-start algorithm is used to refine the localization, fused with the accessibility map and the PIR sensor data. Experiments were conducted in a mock apartment testbed. The ground truth data was obtained from an Opti-track system. The results demonstrate that the proposed method is able to track persons in a smart home environment and provide a solution for home robot localization. PMID:29364188

  4. Inverse modeling methods for indoor airborne pollutant tracking: literature review and fundamentals.

    PubMed

    Liu, X; Zhai, Z

    2007-12-01

    Reduction in indoor environment quality calls for effective control and improvement measures. Accurate and prompt identification of contaminant sources ensures that they can be quickly removed and contaminated spaces isolated and cleaned. This paper discusses the use of inverse modeling to identify potential indoor pollutant sources with limited pollutant sensor data. The study reviews various inverse modeling methods for advection-dispersion problems and summarizes the methods into three major categories: forward, backward, and probability inverse modeling methods. The adjoint probability inverse modeling method is indicated as an appropriate model for indoor air pollutant tracking because it can quickly find source location, strength and release time without prior information. The paper introduces the principles of the adjoint probability method and establishes the corresponding adjoint equations for both multi-zone airflow models and computational fluid dynamics (CFD) models. The study proposes a two-stage inverse modeling approach integrating both multi-zone and CFD models, which can provide a rapid estimate of indoor pollution status and history for a whole building. Preliminary case study results indicate that the adjoint probability method is feasible for indoor pollutant inverse modeling. The proposed method can help identify contaminant source characteristics (location and release time) with limited sensor outputs. This will ensure an effective and prompt execution of building management strategies and thus achieve a healthy and safe indoor environment. The method can also help design optimal sensor networks.

  5. The associations of indoor environment and psychosocial factors on the subjective evaluation of Indoor Air Quality among lower secondary school students: a multilevel analysis.

    PubMed

    Finell, E; Haverinen-Shaughnessy, U; Tolvanen, A; Laaksonen, S; Karvonen, S; Sund, R; Saaristo, V; Luopa, P; Ståhl, T; Putus, T; Pekkanen, J

    2017-03-01

    Subjective evaluation of Indoor Air Quality (subjective IAQ) reflects both building-related and psychosocial factors, but their associations have rarely been studied other than on the individual level in occupational settings and their interactions have not been assessed. Therefore, we studied whether schools' observed indoor air problems and psychosocial factors are associated with subjective IAQ and their potential interactions. The analysis was performed with a nationwide sample (N = 195 schools/26946 students) using multilevel modeling. Two datasets were merged: (i) survey data from students, including information on schools' psychosocial environment and subjective IAQ, and (ii) data from school principals, including information on observed indoor air problems. On the student level, school-related stress, poor teacher-student relationship, and whether the student did not easily receive help from school personnel, were significantly associated with poor subjective IAQ. On the school level, observed indoor air problem (standardized β = -0.43) and poor teacher-student relationship (standardized β = -0.22) were significant predictors of poor subjective IAQ. In addition, school-related stress was associated with poor subjective IAQ, but only in schools without observed indoor air problem (standardized β = -0.44). © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. A holistic approach for the assessment of the indoor environmental quality, student productivity, and energy consumption in primary schools.

    PubMed

    Dorizas, Paraskevi Vivian; Assimakopoulos, Margarita-Niki; Santamouris, Mattheos

    2015-05-01

    The perception of the indoor environmental quality (IEQ) through questionnaires in conjunction with in-field measurements related to the indoor air quality (IAQ), the thermal comfort and the lighting environment were studied in nine naturally ventilated schools of Athens, Greece. Cluster analysis was carried out in order to determine the ranges of indoor air pollutants, temperature (T), relative humidity (RH), and ventilation rates at which the students were satisfied with the indoor environment. It was found that increased levels of particulate matter did not have a negative effect on students' perception while students seemed to link the degradation of IAQ with temperature variations. Statistically significant correlations were further found between measurement results and students' perception of the IEQ. Students' sick building syndrome (SBS) symptoms and performance of schoolwork were also investigated as a function of the levels of indoor air pollutants and ventilation, and there were found significant positive correlations between particulate matter (PM) and certain health symptoms. Students' learning performance seemed to be affected by the ventilation rates and carbon dioxide (CO₂) concentrations while certain health effects positively correlated to the levels of PM and CO₂. The energy consumption of schools was rather low compared to other national findings, and both the electricity and oil consumption for heating positively correlated to the levels of indoor air pollutants.

  7. CATALOG OF MATERIALS AS POTENTIAL SOURCES OF INDOOR AIR EMISSIONS - VOLUME 1. INSULATION, WALLCOVERINGS, RESI- LIENT FLOOR COVERINGS, CARPET, ADHESIVES, SEALANTS AND CAULKS, AND PESTICIDES

    EPA Science Inventory

    The report discusses and presents data on constituents and emissions from products that have the potential to impact the indoor air environment. t is a tool to be used by researchers to help organize the study of materials as potential sources of indoor air emissions. ncluded are...

  8. Urinary Pyrethroid and Chlorpyrifos Metabolite Concentraitons in Northern California families and their relationship to indoor home insecticide levels, part of the Study of Use of Products and Exposure Related Behavior (SUPERB)

    EPA Science Inventory

    Since the 2001 U.S. federally mandated phase-out of residential uses of organophosphate (OP) insecticides, the use of and potential for human exposure to pyrethroid insecticides in the indoor residential environment increases, while that for OPs decreases. Here we report indoor ...

  9. Physical activity patterns of ethnic children from low socio-economic environments within the UK.

    PubMed

    Eyre, Emma Lisa Jane; Duncan, Michael Joseph; Birch, Samantha Louise; Cox, Valerie; Blackett, Matthew

    2015-01-01

    Many children fail to meet physical activity (PA) guidelines for health benefits. PA behaviours are complex and depend on numerous interrelated factors. The study aims to develop current understanding of how children from low Socio-economic environments within the UK use their surrounding built environments for PA by using advanced technology. The environment was assessed in 96 school children (7-9 years) using global positioning system (GPS) monitoring (Garmin Forerunner, 305). In a subsample of 46 children, the environment and PA were assessed using an integrated GPS and heart rate monitor. The percentage of time spent indoor, outdoor, in green and non-green environments along with time spent in moderate-to-vigorous PA (MVPA) in indoor and outdoor environments were assessed. A 2-by-2 repeated measures analysis of covariance, controlling for body mass index, BF%, assessed the environmental differences. The findings show that 42% of children from deprived wards of Coventry fail to meet PA guidelines, of which 43% was accumulated during school. Children engaged in more MVPA outdoor than indoor environments (P < 0.01) and a greater amount of time was spent in non-green environments (P < 0.01). Increased time outdoors was negatively associated with BF%. In conclusion, outdoor environments are important for health-enhancing PA and reducing fatness in deprived and ethnic children.

  10. Residential indoor and personal PM10 exposures of ambient origin based on chemical components.

    PubMed

    Xu, Jia; Bai, Zhipeng; You, Yan; Zhou, Jian; Zhang, Jiefeng; Niu, Can; Liu, Yating; Zhang, Nan; He, Fei; Ding, Xiao

    2014-07-01

    Many studies have focused on the relationships of particulate matter between indoor, outdoor and personal exposure; however, considerable uncertainties remain regarding the portion of indoor particles and personal exposure of ambient origin. As part of the Particle Exposure Assessment for Community Elderly (PEACE) study in Tianjin, China, we have further interpreted the relationships between personal, residential indoor, outdoor and community PM10 (particulate matter with aerodynamic diameters of less than 10 μm). Comparisons of the chemical compositions of PM10 samples were performed using the coefficient of divergence (COD). A robust regression method, least-trimmed squared (LTS) regression, was used to estimate the infiltration factors of PM10 from residential outdoor to indoor environments based on the particulate component concentrations. Personal exposures of ambient origin were also estimated. A relatively good correlation was found between the personal and indoor PM10 samples with respect to chemical composition. The infiltration factors (Finf) of the residential indoor-outdoor PM10 were 0.74±0.31 (mean±SD) in summer and 0.44±0.22 in winter, with medians of 0.98 and 0.48, respectively. The residential outdoor contributions to the indoor environments were 87±55 μg/m(3) in summer and 80±54 μg/m(3) in winter, with medians of 75 μg/m(3) and 61 μg/m(3), respectively. The personal exposures of ambient origin were 92±44 μg/m(3) in summer and 89±47 μg/m(3) in winter, with medians of 81 μg/m(3) and 80 μg/m(3), respectively. This study indicated that the infiltrations in an urbanized area in North China exhibited a seasonal difference: the residential outdoor contributions to residential indoor environments were larger in summer due to the higher use of natural ventilation. The personal exposures of ambient origin were comparable during the different seasons, whereas those of non-ambient origin were higher in summer than in winter.

  11. The analysis of PM2.5 and associated elements and their indoor/outdoor pollution status in an urban area.

    PubMed

    Lim, J-M; Jeong, J-H; Lee, J-H; Moon, J-H; Chung, Y-S; Kim, K-H

    2011-04-01

    In this study, elemental composition of PM2.5 and the status of indoor/outdoor pollution were investigated in a commercial building near a roadside area in Daejeon, Korea. A total of 60 parallel PM2.5 samples were collected both on the roof (outdoor) and in an indoor office of a building near a highly congested road during the spring and fall of 2008. The concentrations of 23 elements were analysed from these PM2.5 samples using instrumental neutron activation analysis. PM2.5 levels in indoor environment (47.6 ± 16.5 μg/m(3)) were noticeably higher than the outdoor levels (37.7 ± 17.2 μg/m(3)) with the I/O concentration ratio of 1.37 ± 0.33 [correlation coefficient (r) = 0.89, P < 0.001]. Principal component analysis results coincidently showed the predominance of sources such as soil dust, traffic, oil/coal combustion and road dust for both indoor and outdoor microenvironments. An isolated source in the indoor environment was assigned to environmental tobacco smoke (ETS) with high factor loading of Ce, Cl, I, K, La and Zn. The overall results of our study indicate that the sources of indoor constituents were strongly dependent on outdoor processes except for the ones affected by independent sources such as ETS. An improved understanding of the factors affecting the indoor PM2.5 concentration levels can lead to the development of an efficient management strategy to control health risks from exposure to indoor PM2.5 and related toxic components. A comparison of our comprehensive data sets indicated that most indoor PM2.5 and associated elemental species were strongly enriched by indoor source activities along with infiltration of ambient outdoor air for a naturally ventilated building. © 2010 John Wiley & Sons A/S.

  12. Indoor air quality analysis based on Hadoop

    NASA Astrophysics Data System (ADS)

    Tuo, Wang; Yunhua, Sun; Song, Tian; Liang, Yu; Weihong, Cui

    2014-03-01

    The air of the office environment is our research object. The data of temperature, humidity, concentrations of carbon dioxide, carbon monoxide and ammonia are collected peer one to eight seconds by the sensor monitoring system. And all the data are stored in the Hbase database of Hadoop platform. With the help of HBase feature of column-oriented store and versioned (automatically add the time column), the time-series data sets are bulit based on the primary key Row-key and timestamp. The parallel computing programming model MapReduce is used to process millions of data collected by sensors. By analysing the changing trend of parameters' value at different time of the same day and at the same time of various dates, the impact of human factor and other factors on the room microenvironment is achieved according to the liquidity of the office staff. Moreover, the effective way to improve indoor air quality is proposed in the end of this paper.

  13. A Modular Localization System as a Positioning Service for Road Transport

    PubMed Central

    Brida, Peter; Machaj, Juraj; Benikovsky, Jozef

    2014-01-01

    In recent times smart devices have attracted a large number of users. Since many of these devices allow position estimation using Global Navigation Satellite Systems (GNSS) signals, a large number of location-based applications and services have emerged, especially in transport systems. However GNSS signals are affected by the environment and are not always present, especially in dense urban environment or indoors. In this work firstly a Modular Localization Algorithm is proposed to allow seamless switching between different positioning modules. This helps us develop a positioning system that is able to provide position estimates in both indoor and outdoor environments without any user interaction. Since the proposed system can run as a service on any smart device, it could allow users to navigate not only in outdoor environments, but also indoors, e.g., underground garages, tunnels etc. Secondly we present the proposal of a 2-phase map reduction algorithm which allows one to significantly reduce the complexity of position estimation processes in case that positioning is performed using a fingerprinting framework. The proposed 2-phase map reduction algorithm can also improve the accuracy of the position estimates by filtering out reference points that are far from the mobile device. Both algorithms were implemented into a positioning system and tested in real world conditions in both indoor and outdoor environments. PMID:25353979

  14. Assessment of zero-equation SGS models for simulating indoor environment

    NASA Astrophysics Data System (ADS)

    Taghinia, Javad; Rahman, Md Mizanur; Tse, Tim K. T.

    2016-12-01

    The understanding of air-flow in enclosed spaces plays a key role to designing ventilation systems and indoor environment. The computational fluid dynamics aspects dictate that the large eddy simulation (LES) offers a subtle means to analyze complex flows with recirculation and streamline curvature effects, providing more robust and accurate details than those of Reynolds-averaged Navier-Stokes simulations. This work assesses the performance of two zero-equation sub-grid scale models: the Rahman-Agarwal-Siikonen-Taghinia (RAST) model with a single grid-filter and the dynamic Smagorinsky model with grid-filter and test-filter scales. This in turn allows a cross-comparison of the effect of two different LES methods in simulating indoor air-flows with forced and mixed (natural + forced) convection. A better performance against experiments is indicated with the RAST model in wall-bounded non-equilibrium indoor air-flows; this is due to its sensitivity toward both the shear and vorticity parameters.

  15. Indoor air quality of everyday use spaces dedicated to specific purposes-a review.

    PubMed

    Marć, Mariusz; Śmiełowska, Monika; Namieśnik, Jacek; Zabiegała, Bożena

    2018-01-01

    According to literature data, some of the main factors which significantly affect the quality of the indoor environment in residential households or apartments are human activities such as cooking, smoking, cleaning, and indoor exercising. The paper presents a literature overview related to air quality in everyday use spaces dedicated to specific purposes which are integral parts of residential buildings, such as kitchens, basements, and individual garages. Some aspects of air quality in large-scale car parks, as a specific type of indoor environment, are also discussed. All those areas are characterized by relatively short time use. On the other hand, high and very high concentration levels of xenobiotics can be observed, resulting in higher exposure risk. The main compounds or group of chemical compounds are presented and discussed. The main factors influencing the type and amount of chemical pollutants present in the air of such areas are indicated.

  16. Indoors forensic entomology: colonization of human remains in closed environments by specific species of sarcosaprophagous flies.

    PubMed

    Pohjoismäki, Jaakko L O; Karhunen, Pekka J; Goebeler, Sirkka; Saukko, Pekka; Sääksjärvi, Ilari E

    2010-06-15

    Fly species that are commonly recovered on human corpses concealed in houses or other dwellings are often dependent on human created environments and might have special features in their biology that allow them to colonize indoor cadavers. In this study we describe nine typical cases involving forensically relevant flies on human remains found indoors in southern Finland. Eggs, larvae and puparia were reared to adult stage and determined to species. Of the five species found the most common were Lucilia sericata Meigen, Calliphora vicina Robineau-Desvoidy and Protophormia terraenovae Robineau-Desvoidy. The flesh fly Sarcophaga caerulescens Zetterstedt is reported for the first time to colonize human cadavers inside houses and a COI gene sequence based DNA barcode is provided for it to help facilitate identification in the future. Fly biology, colonization speed and the significance of indoors forensic entomological evidence are discussed. (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  17. A salient region detection model combining background distribution measure for indoor robots.

    PubMed

    Li, Na; Xu, Hui; Wang, Zhenhua; Sun, Lining; Chen, Guodong

    2017-01-01

    Vision system plays an important role in the field of indoor robot. Saliency detection methods, capturing regions that are perceived as important, are used to improve the performance of visual perception system. Most of state-of-the-art methods for saliency detection, performing outstandingly in natural images, cannot work in complicated indoor environment. Therefore, we propose a new method comprised of graph-based RGB-D segmentation, primary saliency measure, background distribution measure, and combination. Besides, region roundness is proposed to describe the compactness of a region to measure background distribution more robustly. To validate the proposed approach, eleven influential methods are compared on the DSD and ECSSD dataset. Moreover, we build a mobile robot platform for application in an actual environment, and design three different kinds of experimental constructions that are different viewpoints, illumination variations and partial occlusions. Experimental results demonstrate that our model outperforms existing methods and is useful for indoor mobile robots.

  18. An Improved Indoor Positioning System Using RGB-D Cameras and Wireless Networks for Use in Complex Environments.

    PubMed

    Duque Domingo, Jaime; Cerrada, Carlos; Valero, Enrique; Cerrada, Jose A

    2017-10-20

    This work presents an Indoor Positioning System to estimate the location of people navigating in complex indoor environments. The developed technique combines WiFi Positioning Systems and depth maps , delivering promising results in complex inhabited environments, consisting of various connected rooms, where people are freely moving. This is a non-intrusive system in which personal information about subjects is not needed and, although RGB-D cameras are installed in the sensing area, users are only required to carry their smart-phones. In this article, the methods developed to combine the above-mentioned technologies and the experiments performed to test the system are detailed. The obtained results show a significant improvement in terms of accuracy and performance with respect to previous WiFi-based solutions as well as an extension in the range of operation.

  19. Reference Guide. Indoor Air Quality Tools for Schools

    ERIC Educational Resources Information Center

    US Environmental Protection Agency, 2009

    2009-01-01

    Understanding the importance of good indoor air quality (IAQ) in schools is the backbone of developing an effective Indoor Air Quality (IAQ) program. Poor IAQ can lead to a large variety of health problems and potentially affect comfort, concentration, and staff/student performance. In recognition of tight school budgets, this guidance is designed…

  20. Environmental tobacco smoke exposure assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guerin, M.R.

    Environmental tobacco smoke (ETS) is the material released into the environment as tobacco products are smoked. Cigarettes, pipes, and cigars all produce ETS but the term has become all but synonymous with indoor air contamination by cigarette smoking. This is because cigarettes are by far the most commonly consumed tobacco product and because the principal human exposure occurs indoors. Exposure to ETS is variously termed as passive smoking, involuntary smoking, and as exposure to second-hand smoke. Considerable progress has been made toward a better understanding of ETS exposure. Strengths and limitations of various measures of exposure are better understood andmore » much data has been generated on the quantities of many ETS-constituents in many indoor environments. The properties of ETS, methods for its measurement in indoor air, and many results of field studies have recently been reviewed by the author. The recent EPA report includes a major treatment of exposure estimation including air concentrations, questionnaires, and biomarkers. This paper discusses approaches to exposure assessment and summarizes data on indoor air concentrations of ETS-constituents.« less

  1. Chamber Bioaerosol Study: Outdoor Air and Human Occupants as Sources of Indoor Airborne Microbes

    PubMed Central

    Adams, Rachel I.; Bhangar, Seema; Pasut, Wilmer; Arens, Edward A.; Taylor, John W.; Lindow, Steven E.; Nazaroff, William W.; Bruns, Thomas D.

    2015-01-01

    Human occupants are an important source of microbes in indoor environments. In this study, we used DNA sequencing of filter samples to assess the fungal and bacterial composition of air in an environmental chamber under different levels of occupancy, activity, and exposed or covered carpeting. In this office-like, mechanically ventilated environment, results showed a strong influence of outdoor-derived particles, with the indoor microbial composition tracking that of outdoor air for the 2-hour sampling periods. The number of occupants and their activity played a significant but smaller role influencing the composition of indoor bioaerosols. Human-associated taxa were observed but were not particularly abundant, except in the case of one fungus that appeared to be transported into the chamber on the clothing of a study participant. Overall, this study revealed a smaller signature of human body-associated taxa than had been expected based on recent studies of indoor microbiomes, suggesting that occupants may not exert a strong influence on bioaerosol microbial composition in a space that, like many offices, is well ventilated with air that is moderately filtered and moderately occupied. PMID:26024222

  2. [Concentration and Size Distribution of Bioaerosols in Indoor Environment of University Dormitory During the Plum Rain Period].

    PubMed

    Liu, Ting; Li, Lu; Zhang, Jia-quan; Zhan, Chang-lin; Liu, Hong-xia; Zheng, Jing-ru; Yao, Rui-zhen; Cao, Jun-ji

    2016-04-15

    Bioaerosols of university dormitory can spread through air and cause a potential health risk for student staying in indoor environment. To quantify the characteristics of bioaerosols in indoor environment of university dormitory, concentration and size distribution of culturable bioaerosols were detected during the plum rain period, the correlations of culturable bioaerosol with concentration of particulate matter, the ambient temperature and relative humidity were analyzed using Spearman's correlation coefficient and finally the changes of size distribution of culturable bioaerosol caused by activities of students were detected. The results showed that the mean concentrations of culturable airborne bacteria and fungi were (2133 +/- 1617) CFUm' and (3111 +/- 2202) CFU x m(-3). The concentrations of culturable airborne bacteria and fungi exhibited negative correlation with PM1, PM2.5, and PM10, respectively. The respirable fractions of bacteria exhibited positive correlation with PM2.5, and the respirable fractions of fungi exhibited significant positive correlation with PM10. Ambient temperature had positive correlation with culturable airborne bacteria and fungi, and relative humidity had negative correlation with culturable airborne bacteria and fungi. In the afternoon, concentrations of culturable airborne fungi in indoor environment of university dormitory significantly increased, and the size distribution of culturable hioaerosols was different in the morning and afternoon.

  3. Practical Implementation of Semi-Automated As-Built Bim Creation for Complex Indoor Environments

    NASA Astrophysics Data System (ADS)

    Yoon, S.; Jung, J.; Heo, J.

    2015-05-01

    In recent days, for efficient management and operation of existing buildings, the importance of as-built BIM is emphasized in AEC/FM domain. However, fully automated as-built BIM creation is a tough issue since newly-constructed buildings are becoming more complex. To manage this problem, our research group has developed a semi-automated approach, focusing on productive 3D as-built BIM creation for complex indoor environments. In order to test its feasibility for a variety of complex indoor environments, we applied the developed approach to model the `Charlotte stairs' in Lotte World Mall, Korea. The approach includes 4 main phases: data acquisition, data pre-processing, geometric drawing, and as-built BIM creation. In the data acquisition phase, due to its complex structure, we moved the scanner location several times to obtain the entire point clouds of the test site. After which, data pre-processing phase entailing point-cloud registration, noise removal, and coordinate transformation was followed. The 3D geometric drawing was created using the RANSAC-based plane detection and boundary tracing methods. Finally, in order to create a semantically-rich BIM, the geometric drawing was imported into the commercial BIM software. The final as-built BIM confirmed that the feasibility of the proposed approach in the complex indoor environment.

  4. School Indoor Air Quality Assessment and Program Implementation.

    ERIC Educational Resources Information Center

    Prill, R.; Blake, D.; Hales, D.

    This paper describes the effectiveness of a three-step indoor air quality (IAQ) program implemented by 156 schools in the states of Washington and Idaho during the 2000-2001 school year. An experienced IAQ/building science specialist conducted walk-through assessments at each school. These assessments documented deficiencies and served as an…

  5. Indoor Air Quality Management Program.

    ERIC Educational Resources Information Center

    Anne Arundel County Public Schools, Annapolis, MD.

    In an effort to provide Indoor Air Quality (IAQ) management guidance, Anne Arundel County Public Schools was selected by the Maryland State Department of Education to develop a program that could be used by other school systems. A major goal was to produce a handbook that was "user friendly." Hence, its contents are a mix of history,…

  6. Indoor Allergens and Allergic Respiratory Disease

    PubMed Central

    Chapman, Martin D.; Wünschmann, Sabina

    2016-01-01

    Purpose of review The purpose of this review is to evaluate the most recent findings on indoor allergens and their impact on allergic diseases. Recent findings Indoor allergens are present inside buildings (home, work environment, school), and given the chronic nature of the exposures, indoor allergies tend to be associated with the development of asthma. The most common indoor allergens are derived from dust mites, cockroaches, mammals (including wild rodents and pets), and fungi. The advent of molecular biology and proteomics has led to the identification, cloning, and expression of new indoor allergens, which have facilitated research to elucidate their role in allergic diseases. This review is an update on new allergens and their molecular features, together with the most recent reports on their avoidance for allergy prevention and their use for diagnosis and treatment. Summary Research progress on indoor allergens will result in the development of new diagnostic tools and design of coherent strategies for immunotherapy. PMID:27184001

  7. Microbiological Assessment of Indoor Air of Teaching Hospital Wards: A case of Jimma University Specialized Hospital.

    PubMed

    Fekadu, Samuel; Getachewu, Bahilu

    2015-04-01

    Hospital environment represents a congenial situation where microorganisms and susceptible patients are indoors together. Thus, the objective of this study is to provide fundamental data related to the microbial quality of indoor air of Jimma University Specialized Hospital wards, to estimate the health hazard and to create standards for indoor air quality control. The microbial quality of indoor air of seven wards of Jimma University Specialized Hospital was determined. Passive air sampling technique, using open Petri-dishes containing different culture media, was employed to collect sample twice daily. The concentrations of bacteria and fungi aerosols in the indoor environment of the wards ranged between 2123 - 9733 CFU/m(3). The statistical analysis showed that the concentrations of bacteria that were measured in all studied wards were significantly different from each other (p-value=0.017), whereas the concentrations of fungi that were measured in all sampled wards were not significantly different from each other (p-value=0.850). Moreover, the concentrations of bacteria that were measured at different sampling time (morning and afternoon) were significantly different (p-value =0.001). All wards that were included in the study were heavily contaminated with bacteria and fungi. Thus, immediate interventions are needed to control those environmental factors which favor the growth and multiplication of microbes, and it is vital to control visitors and students in and out the wards. Moreover, it is advisable that strict measures be put in place to check the increasing microbial load in the hospital environment.

  8. Health symptoms in relation to temperature, humidity, and self-reported perceptions of climate in New York City residential environments

    NASA Astrophysics Data System (ADS)

    Quinn, Ashlinn; Shaman, Jeffrey

    2017-07-01

    Little monitoring has been conducted of temperature and humidity inside homes despite the fact that these conditions may be relevant to health outcomes. Previous studies have observed associations between self-reported perceptions of the indoor environment and health. Here, we investigate associations between measured temperature and humidity, perceptions of indoor environmental conditions, and health symptoms in a sample of New York City apartments. We measured temperature and humidity in 40 New York City apartments during summer and winter seasons and collected survey data from the households' residents. Health outcomes of interest were (1) sleep quality, (2) symptoms of heat illness (summer season), and (3) symptoms of respiratory viral infection (winter season). Using mixed-effects logistic regression models, we investigated associations between the perceptions, symptoms, and measured conditions in each season. Perceptions of indoor temperature were significantly associated with measured temperature in both the summer and the winter, with a stronger association in the summer season. Sleep quality was inversely related to measured and perceived indoor temperature in the summer season only. Heat illness symptoms were associated with perceived, but not measured, temperature in the summer season. We did not find an association between any measured or perceived condition and cases of respiratory infection in the winter season. Although limited in size, the results of this study reveal that indoor temperature may impact sleep quality, and that thermal perceptions of the indoor environment may indicate vulnerability to heat illness. These are both important avenues for further investigation.

  9. Do indoor environments in schools influence student performance? A review of the literature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendell, Mark J.; Heath, Garvin A.

    2004-11-24

    Limited research is available on potential adverse effects of school environments on academic performance, despite strong public concern. We examine the scientific evidence relevant to this relationship by reviewing available research relating schools and other indoor environments to human performance or attendance. As a primary focus, we critically review evidence for direct relationships between indoor environmental quality (IEQ) in buildings and performance or attendance. As a secondary focus, we summarize, without critique, evidence on potential connections indirectly linking IEQ to performance or attendance: relationships between IEQ and health, between health and performance or attendance, and between attendance and performance. Themore » most persuasive direct evidence showed increases in indoor concentrations of nitrogen dioxide and outdoor concentrations of several specific pollutants to be related to reduced school attendance. The most persuasive indirect evidence showed indoor dampness and microbiologic pollutants to be related to asthma and respiratory infections, which have in turn been related to reduced performance and attendance. Furthermore, a substantial scientific literature links poor IEQ (e.g., low ventilation rate, excess moisture or formaldehyde) with respiratory and other health effects in children and adults. Overall, evidence suggests that poor IEQ in schools can influence the performance and attendance of students, primarily through health effects from indoor pollutants. Also, inadequate IEQ in schools seems sufficiently common to merit strong public concern. Evidence is available to justify (1) immediate actions to protect IEQ in schools and (2) focused research on exposures, prevention, and causation, to better guide policies and actions on IEQ in schools.« less

  10. The Isprs Benchmark on Indoor Modelling

    NASA Astrophysics Data System (ADS)

    Khoshelham, K.; Díaz Vilariño, L.; Peter, M.; Kang, Z.; Acharya, D.

    2017-09-01

    Automated generation of 3D indoor models from point cloud data has been a topic of intensive research in recent years. While results on various datasets have been reported in literature, a comparison of the performance of different methods has not been possible due to the lack of benchmark datasets and a common evaluation framework. The ISPRS benchmark on indoor modelling aims to address this issue by providing a public benchmark dataset and an evaluation framework for performance comparison of indoor modelling methods. In this paper, we present the benchmark dataset comprising several point clouds of indoor environments captured by different sensors. We also discuss the evaluation and comparison of indoor modelling methods based on manually created reference models and appropriate quality evaluation criteria. The benchmark dataset is available for download at: http://www2.isprs.org/commissions/comm4/wg5/benchmark-on-indoor-modelling.html.

  11. Smartphone-based integrated PDR/GPS/Bluetooth pedestrian location

    NASA Astrophysics Data System (ADS)

    Li, Xianghong; Wei, Dongyan; Lai, Qifeng; Xu, Ying; Yuan, Hong

    2017-02-01

    Typical indoor location method is fingerprint and traditional outdoor location system is GPS. Both of them are of poor accuracy and limited only for indoor or outdoor environments. As the smartphones are equipped with MEMS sensors, it means PDR can be widely used. In this paper, an algorithm of smartphone-based integrated PDR/GPS/Bluetooth for pedestrian location in the indoor/outdoor is proposed, which can be highly expected to realize seamless indoor/outdoor localization of the pedestrian. In addition, we also provide technologies to estimate orientation with Magnetometer and Gyroscope and detect context with output of sensors. The extensive experimental results show that the proposed algorithm can realize seamless indoor/outdoor localization.

  12. Center for Building Science: Annual report, FY 1986

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cairns, E.J.; Rosenfeld, A.H.

    1987-05-01

    The Center for Building Science consists of four programs in the Applied Science Division: energy analysis, buildings energy systems, windows and lighting, and indoor environment. It was established to provide an umbrella so that goups in different programs but with similar interests could combine to perform joint research, develop new research areas, share resources, and produce joint publications. As detailed below, potential savings for the U.S. society from energy efficient buildings are enormous. But these savings can only be realized through an expanding federal RandD program that develops expertise in this new area. The Center for Building Science develops efficientmore » new building componenets, computer models, data and information systems, and trains needed builidng scientists. 135 refs., 72 figs., 18 tabs.« less

  13. Children exposure to indoor ultrafine particles in urban and rural school environments.

    PubMed

    Cavaleiro Rufo, João; Madureira, Joana; Paciência, Inês; Slezakova, Klara; Pereira, Maria do Carmo; Aguiar, Lívia; Teixeira, João Paulo; Moreira, André; Oliveira Fernandes, Eduardo

    2016-07-01

    Extended exposure to ultrafine particles (UFPs) may lead to consequences in children due to their increased susceptibility when compared to older individuals. Since children spend in average 8 h/day in primary schools, assessing the number concentrations of UFPs in these institutions is important in order to evaluate the health risk for children in primary schools caused by indoor air pollution. Thus, the purpose of this study was to assess and determine the sources of indoor UFP number concentrations in urban and rural Portuguese primary schools. Indoor and outdoor ultrafine particle (UFP) number concentrations were measured in six urban schools (US) and two rural schools (RS) located in the north of Portugal, during the heating season. The mean number concentrations of indoor UFPs were significantly higher in urban schools than in rural ones (10.4 × 10(3) and 5.7 × 10(3) pt/cm(3), respectively). Higher UFP levels were associated with higher squared meters per student, floor levels closer to the ground, chalk boards, furniture or floor covering materials made of wood and windows with double-glazing. Indoor number concentrations of ultrafine-particles were inversely correlated with indoor CO2 levels. In the present work, indoor and outdoor concentrations of UFPs in public primary schools located in urban and rural areas were assessed, and the main sources were identified for each environment. The results not only showed that UFP pollution is present in augmented concentrations in US when compared to RS but also revealed some classroom/school characteristics that influence the concentrations of UFPs in primary schools.

  14. A Visual-Based Approach for Indoor Radio Map Construction Using Smartphones.

    PubMed

    Liu, Tao; Zhang, Xing; Li, Qingquan; Fang, Zhixiang

    2017-08-04

    Localization of users in indoor spaces is a common issue in many applications. Among various technologies, a Wi-Fi fingerprinting based localization solution has attracted much attention, since it can be easily deployed using the existing off-the-shelf mobile devices and wireless networks. However, the collection of the Wi-Fi radio map is quite labor-intensive, which limits its potential for large-scale application. In this paper, a visual-based approach is proposed for the construction of a radio map in anonymous indoor environments. This approach collects multi-sensor data, e.g., Wi-Fi signals, video frames, inertial readings, when people are walking in indoor environments with smartphones in their hands. Then, it spatially recovers the trajectories of people by using both visual and inertial information. Finally, it estimates the location of fingerprints from the trajectories and constructs a Wi-Fi radio map. Experiment results show that the average location error of the fingerprints is about 0.53 m. A weighted k-nearest neighbor method is also used to evaluate the constructed radio map. The average localization error is about 3.2 m, indicating that the quality of the constructed radio map is at the same level as those constructed by site surveying. However, this approach can greatly reduce the human labor cost, which increases the potential for applying it to large indoor environments.

  15. Characterizing the bacterial communities in retail stores in the United States.

    PubMed

    Hoisington, A; Maestre, J P; Kinney, K A; Siegel, J A

    2016-12-01

    The microorganisms present in retail environments have not been studied in detail despite the fact that these environments represent a potentially important location for exposure. In this study, HVAC filter dust samples in 13 US retail stores were collected and analyzed via pyrosequencing to characterize the indoor bacterial communities and to explore potential relationships between these communities and building and environmental parameters. Although retail stores contained a diverse bacterial community of 788 unique genera, over half of the nearly 118K sequences were attributed to the Proteobacteria phylum. Streptophyta, Bacillus, Corynebacterium, Pseudomonas, and Acinetobacter were the most prevalent genera detected. The recovered indoor airborne microbial community was statistically associated with both human oral and skin microbiota, indicating occupants are important contributors, despite a relatively low occupant density per unit volume in retail stores. Bacteria generally associated with outdoor environments were present in the indoor communities with no obvious association with air exchange rate, even when considering relative abundance. No significant association was observed between the indoor bacterial community recovered and store location, store type, or season. However, predictive functional gene profiling showed significant associations between the indoor community and season. The microbiome recovered from multiple samples collected months apart from the same building varied significantly indicating that caution is warranted when trying to characterize the bacterial community with a single sampling event. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. A fast and precise indoor localization algorithm based on an online sequential extreme learning machine.

    PubMed

    Zou, Han; Lu, Xiaoxuan; Jiang, Hao; Xie, Lihua

    2015-01-15

    Nowadays, developing indoor positioning systems (IPSs) has become an attractive research topic due to the increasing demands on location-based service (LBS) in indoor environments. WiFi technology has been studied and explored to provide indoor positioning service for years in view of the wide deployment and availability of existing WiFi infrastructures in indoor environments. A large body of WiFi-based IPSs adopt fingerprinting approaches for localization. However, these IPSs suffer from two major problems: the intensive costs of manpower and time for offline site survey and the inflexibility to environmental dynamics. In this paper, we propose an indoor localization algorithm based on an online sequential extreme learning machine (OS-ELM) to address the above problems accordingly. The fast learning speed of OS-ELM can reduce the time and manpower costs for the offline site survey. Meanwhile, its online sequential learning ability enables the proposed localization algorithm to adapt in a timely manner to environmental dynamics. Experiments under specific environmental changes, such as variations of occupancy distribution and events of opening or closing of doors, are conducted to evaluate the performance of OS-ELM. The simulation and experimental results show that the proposed localization algorithm can provide higher localization accuracy than traditional approaches, due to its fast adaptation to various environmental dynamics.

  17. Development of indoor environmental index: Air quality index and thermal comfort index

    NASA Astrophysics Data System (ADS)

    Saad, S. M.; Shakaff, A. Y. M.; Saad, A. R. M.; Yusof, A. M.; Andrew, A. M.; Zakaria, A.; Adom, A. H.

    2017-03-01

    In this paper, index for indoor air quality (also known as IAQI) and thermal comfort index (TCI) have been developed. The IAQI was actually modified from previous outdoor air quality index (AQI) designed by the United States Environmental Protection Agency (US EPA). In order to measure the index, a real-time monitoring system to monitor indoor air quality level was developed. The proposed system consists of three parts: sensor module cloud, base station and service-oriented client. The sensor module cloud (SMC) contains collections of sensor modules that measures the air quality data and transmit the captured data to base station through wireless. Each sensor modules includes an integrated sensor array that can measure indoor air parameters like Carbon Dioxide, Carbon Monoxide, Ozone, Nitrogen Dioxide, Oxygen, Volatile Organic Compound and Particulate Matter. Temperature and humidity were also being measured in order to determine comfort condition in indoor environment. The result from several experiments show that the system is able to measure the air quality presented in IAQI and TCI in many indoor environment settings like air-conditioner, chemical present and cigarette smoke that may impact the air quality. It also shows that the air quality are changing dramatically, thus real-time monitoring system is essential.

  18. Analyzing symptom data in indoor air questionnaires for primary schools.

    PubMed

    Ung-Lanki, S; Lampi, J; Pekkanen, J

    2017-09-01

    Questionnaires on symptoms and perceived quality of indoor environment are used to assess indoor environment problems, but mainly among adults. The aim of this article was to explore best ways to analyze and report such symptom data, as part of a project to develop a parent-administered indoor air questionnaire for primary school pupils. Indoor air questionnaire with 25 questions on child's symptoms in the last 4 weeks was sent to parents in five primary schools with indoor air problems and in five control schools. About 83% of parents (N=1470) in case schools and 82% (N=805) in control schools returned the questionnaire. In two schools, 351 (52%) parents answered the questionnaire twice with a 2-week interval. Based on prevalence of symptoms, their test-retest repeatability (ICC), and on principal component analysis (PCA), the number of symptoms was reduced to 17 and six symptoms scores were developed. Six variants of these six symptom scores were then formed and their ability to rank schools compared. Four symptom scores (respiratory, lower respiratory, eye, and general symptoms) analyzed dichotomized maintained sufficiently well the diversity of symptom data and captured the between-school differences in symptom prevalence, when compared to more complex and numerous scores. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. A real-time monitoring and assessment method for calculation of total amounts of indoor air pollutants emitted in subway stations.

    PubMed

    Oh, TaeSeok; Kim, MinJeong; Lim, JungJin; Kang, OnYu; Shetty, K Vidya; SankaraRao, B; Yoo, ChangKyoo; Park, Jae Hyung; Kim, Jeong Tai

    2012-05-01

    Subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, in this study, a new cumulative calculation method for the estimation of total amounts of indoor air pollutants emitted inside the subway station is proposed by taking cumulative amounts of indoor air pollutants based on integration concept. Minimum concentration of individual air pollutants which naturally exist in indoor space is referred as base concentration of air pollutants and can be found from the data collected. After subtracting the value of base concentration from data point of each data set of indoor air pollutant, the primary quantity of emitted air pollutant is calculated. After integration is carried out with these values, adding the base concentration to the integration quantity gives the total amount of indoor air pollutant emitted. Moreover the values of new index for cumulative indoor air quality obtained for 1 day are calculated using the values of cumulative air quality index (CAI). Cumulative comprehensive indoor air quality index (CCIAI) is also proposed to compare the values of cumulative concentrations of indoor air pollutants. From the results, it is clear that the cumulative assessment approach of indoor air quality (IAQ) is useful for monitoring the values of total amounts of indoor air pollutants emitted, in case of exposure to indoor air pollutants for a long time. Also, the values of CCIAI are influenced more by the values of concentration of NO2, which is released due to the use of air conditioners and combustion of the fuel. The results obtained in this study confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well. Nowadays, subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in the indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, this paper presents a new methodology for monitoring and assessing total amounts of indoor air pollutants emitted inside underground spaces and subway stations. A new methodology for the calculation of cumulative amounts of indoor air pollutants based on integration concept is proposed. The results suggest that the cumulative assessment approach of IAQ is useful for monitoring the values of total amounts of indoor air pollutants, if indoor air pollutants accumulated for a long time, especially NO2 pollutants. The results obtained here confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well.

  20. Composition of heavy metals and airborne fibers in the indoor environment of a building during renovation.

    PubMed

    Latif, Mohd Talib; Baharudin, Nor Hafizah; Velayutham, Puvaneswary; Awang, Normah; Hamdan, Harimah; Mohamad, Ruqyyah; Mokhtar, Mazlin B

    2011-10-01

    The renovation of a building will certainly affect the quality of air in the vicinity of where associated activities were undertaken, this includes the quality of air inside the building. Indoor air pollutants such as particulate matter, heavy metals, and fine fibers are likely to be emitted during renovation work. This study was conducted to determine the concentration of heavy metals, asbestos and suspended particulates in the Biology Building, at the Universiti Kebangsaan, Malaysia (UKM). Renovation activities were carried out widely in the laboratories which were located in this building. A low-volume sampler was used to collect suspended particulate matter of a diameter size less than 10 μm (PM₁₀) and an air sampling pump, fitted with a cellulose ester membrane filter, were used for asbestos sampling. Dust was collected using a small brush and scope. The concentration of heavy metals was determined through the use of inductively coupled plasma-mass spectroscopy and the fibers were counted through a phase contrast microscope. The concentrations of PM₁₀ recorded in the building during renovation action (ranging from 166 to 542 μg m⁻³) were higher than the value set by the Department of Safety and Health for respirable dust (150 μg m⁻³). Additionally, they were higher than the value of PM₁₀ recorded in indoor environments from other studies. The composition of heavy metals in PM₁₀ and indoor dust were found to be dominated by Zn and results also showed that the concentration of heavy metals in indoor dust and PM₁₀ in this study was higher than levels recorded in other similar studies. The asbestos concentration was 0.0038 ± 0.0011 fibers/cc. This was lower than the value set by the Malaysian Department of Occupational, Safety and Health (DOSH) regulations of 0.1 fibers/cc, but higher than the background value usually recorded in indoor environments. This study strongly suggests that renovation issues need to be considered seriously by relevant stakeholders within the university in order to ensure that the associated risks toward humans and indoor environment are eliminated, or where this is not feasible, minimized as far as possible.

  1. California's program: Indoor air problems aren't amenable to regulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wesolowski, J.

    In 1982, California's legislature established an Indoor Air Quality Program (CIAQP) in the Department of Health Services to carry out research on the nature and extent of the indoor air problem (excluding industrial worksites), to find appropriate mitigation measures, and to promote and coordinate the efforts of other state agencies. Since indoor air problems usually are not amenable to regulatory solutions, regulatory authority was not included in the mandate. The program conducts research into a wide range of contaminants--radon, asbestos, formaldehyde, carbon monoxide, volatile organic compounds, environmental tobacco smoke (ETS), as well as into biological aerosols that cause such diseasesmore » as Legionnaires disease, tuberculosis, allergies, and asthma. Studies are also carried out to better understand the Sick Building Syndrome. The research includes field surveys to determine the exposure of the population to specific contaminants and experiments in the laboratory to develop protocols for reducing exposures. The research emphasizes measurement of exposure--concentration multiplied by the time a person is exposed--as opposed to measurement of concentration only.« less

  2. PENETRATION OF AMBIENT FINE PARTICLES INTO THE INDOOR ENVIRONMENT

    EPA Science Inventory

    Several recent studies have indicated significant health risks associated with exposure to fine particles as measured outdoors. However, much of the exposure is believed to have occurred infdoors. consequently, there is considerable interest in the relationship between indoor a...

  3. Into Thin Air.

    ERIC Educational Resources Information Center

    Kennedy, Mike

    2001-01-01

    Shows how schools are working to avoid the types of equipment, supplies, and maintenance practices that harm indoor air quality. Simple steps to maintaining a cleaner indoor air environment are highlighted as are steps to reducing the problem air quality and the occurrence of asthma. (GR)

  4. Workload comparison between hiking and indoor physical activity.

    PubMed

    Fattorini, Luigi; Pittiglio, Giancarlo; Federico, Bruno; Pallicca, Anastasia; Bernardi, Marco; Rodio, Angelo

    2012-10-01

    Walking is a physical activity able to maintain and improve aerobic fitness. This activity can easily be performed in all seasons both outdoors and indoors, but when it is performed in its natural environment, the use of specific equipment is required. In particular, it has been demonstrated that the use of trekking boots (TBs) induces a larger workload than those used indoors. Because an adequate fitness level is needed to practice hiking in safety, it is useful to know the energy demand of such an activity. This research aims at defining the metabolic engagement of hiking on natural paths with specific equipment at several speeds and comparing this with indoor ones (on a treadmill). This can thence be used to define the load that better reflects the one required to walk on natural paths. The walking energy cost (joules per kilogram per meter) at several speeds (0.28, 0.56, 0.84, 1.11, and 1.39 m·s(-1))-on level natural terrain while wearing suitable footwear (TBs) and on a treadmill at various raising slopes (0, 1, 2, 3, 4%) while wearing running shoes-was measured in 14 healthy young men (age 23.9 ± 2.9 years, stature 1.75 ± 0.04 m, and body mass 72.9 ± 6.3 kg). A physiological evaluation of all the subjects was performed before energy cost measurements. The results showed that outdoors, the oxygen uptake was consistently less than the ventilatory threshold at all speeds tested and that a 3% slope on the treadmill best reflects the outdoor walking energy expenditure. These findings will prove useful to plan proper training for hiking activity or mixed (outdoors and indoors) training program.

  5. Constructing an Indoor Floor Plan Using Crowdsourcing Based on Magnetic Fingerprinting

    PubMed Central

    Zhao, Fang; Jiang, Mengling; Ma, Hao; Zhang, Yuexia

    2017-01-01

    A large number of indoor positioning systems have recently been developed to cater for various location-based services. Indoor maps are a prerequisite of such indoor positioning systems; however, indoor maps are currently non-existent for most indoor environments. Construction of an indoor map by external experts excludes quick deployment and prevents widespread utilization of indoor localization systems. Here, we propose an algorithm for the automatic construction of an indoor floor plan, together with a magnetic fingerprint map of unmapped buildings using crowdsourced smartphone data. For floor plan construction, our system combines the use of dead reckoning technology, an observation model with geomagnetic signals, and trajectory fusion based on an affinity propagation algorithm. To obtain the indoor paths, the magnetic trajectory data obtained through crowdsourcing were first clustered using dynamic time warping similarity criteria. The trajectories were inferred from odometry tracing, and those belonging to the same cluster in the magnetic trajectory domain were then fused. Fusing these data effectively eliminates the inherent tracking errors originating from noisy sensors; as a result, we obtained highly accurate indoor paths. One advantage of our system is that no additional hardware such as a laser rangefinder or wheel encoder is required. Experimental results demonstrate that our proposed algorithm successfully constructs indoor floor plans with 0.48 m accuracy, which could benefit location-based services which lack indoor maps. PMID:29156639

  6. Building-associated neurological damage modeled in human cells: a mechanism of neurotoxic effects by exposure to mycotoxins in the indoor environment.

    PubMed

    Karunasena, Enusha; Larrañaga, Michael D; Simoni, Jan S; Douglas, David R; Straus, David C

    2010-12-01

    Damage to human neurological system cells resulting from exposure to mycotoxins confirms a previously controversial public health threat for occupants of water-damaged buildings. Leading scientific organizations disagree about the ability of inhaled mycotoxins in the indoor environment to cause adverse human health effects. Damage to the neurological system can result from exposure to trichothecene mycotoxins in the indoor environment. This study demonstrates that neurological system cell damage can occur from satratoxin H exposure to neurological cells at exposure levels that can be found in water-damaged buildings contaminated with fungal growth. The constant activation of inflammatory and apoptotic pathways at low levels of exposure in human brain capillary endothelial cells, astrocytes, and neural progenitor cells may amplify devastation to neurological tissues and lead to neurological system cell damage from indirect events triggered by the presence of trichothecenes.

  7. The impact of wood stove technology upgrades on indoor residential air quality

    NASA Astrophysics Data System (ADS)

    Allen, Ryan W.; Leckie, Sara; Millar, Gail; Brauer, Michael

    2009-12-01

    Fine particulate matter (PM 2.5) air pollution has been linked to adverse health impacts, and combustion sources including residential wood-burning may play an important role in some regions. Recent evidence suggests that indoor air quality may improve in homes where older, non-certified wood stoves are exchanged for lower emissions EPA-certified alternatives. As part of a wood stove exchange program in northern British Columbia, Canada, we sampled outdoor and indoor air at 15 homes during 6-day sampling sessions both before and after non-certified wood stoves were exchanged. During each sampling session two consecutive 3-day PM 2.5 samples were collected onto Teflon filters, which were weighed and analyzed for the wood smoke tracer levoglucosan. Residential PM 2.5 infiltration efficiencies ( Finf) were estimated from continuous light scattering measurements made with nephelometers, and estimates of Finf were used to calculate the outdoor- and indoor-generated contributions to indoor air. There was not a consistent relationship between stove technology and outdoor or indoor concentrations of PM 2.5 or levoglucosan. Mean Finf estimates were low and similar during pre- and post-exchange periods (0.32 ± 0.17 and 0.33 ± 0.17, respectively). Indoor sources contributed the majority (˜65%) of the indoor PM 2.5 concentrations, independent of stove technology, although low indoor-outdoor levoglucosan ratios (median ≤ 0.19) and low indoor PM 2.5-levoglucosan correlations ( r ≤ 0.19) suggested that wood smoke was not a major indoor PM 2.5 source in most of these homes. In summary, despite the potential for extensive wood stove exchange programs to reduce outdoor PM 2.5 concentrations in wood smoke-impacted communities, we did not find a consistent relationship between stove technology upgrades and indoor air quality improvements in homes where stoves were exchanged.

  8. Influence of Indoor Hygrothermal Conditions on Human Quality of Life in Social Housing.

    PubMed

    Soares, Sara; Fraga, Silvia; Delgado, Joao M P Q; Ramos, Nuno M M

    2015-11-17

    Modern societies spend most of their time indoors, namely at home, and the indoor environment quality turns out to be a crucial factor to health, quality of life and well-being of the residents. The present study aims to understand how indoor environment relates with quality of life and how improving housing conditions impacts on individuals' health. This study case will rely on the following assessments in both rehabilitated and non-rehabilitated social housing: i) field measurements, in social dwellings (namely temperature, relative humidity, carbon dioxide concentration, air velocity, air change rate, level of mould spores and energy consumption); ii) residents' questionnaires on social, demogaphic, behavioural, health characteristics and quality of life. Also, iii) qualitative interviews performed with social housing residents from the rehabilitated houses, addressing the self-perception of living conditions and their influence in health status and quality of life. All the collected information will be combined and analysed in order to achieve the main objective. It is expected to define a Predicted Human Life Quality (PHLQ) index, that combines physical parameters describing the indoor environment measured through engineering techniques with residents' and neighbourhood quality of life characteristics assessed by health questionnaires. Improvement in social housing should be related with better health indicators and the new index might be an important tool contributing to enhance quality of life of the residents. Significance for public healthThis study will contribute to understand how indoor environment relates with quality of life and how improving housing conditions impacts on individuals' health, in social housing neighbourhoods. As so, it is important to share the undertaken methodology carried out by a multidisciplinary team, in order to allow other researchers following comparable studies to adopt a similar approach. The case study results will allow to define building rehabilitation policies, improving residents' quality of life and adding great contribution to public health promotion.

  9. Weatherization and Indoor Air Quality: Measured Impacts in Single Family Homes Under the Weatherization Assistance Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pigg, Scott; Cautley, Dan; Francisco, Paul

    2014-09-01

    This report summarizes findings from a national field study of indoor air quality parameters in homes treated under the Weatherization Assistance Program (WAP). The study involved testing and monitoring in 514 single-family homes (including mobile homes) located in 35 states and served by 88 local weatherization agencies.

  10. Sustainability evaluation of different systems for sea cucumber ( Apostichopus japonicus) farming based on emergy theory

    NASA Astrophysics Data System (ADS)

    Wang, Guodong; Dong, Shuanglin; Tian, Xiangli; Gao, Qinfeng; Wang, Fang

    2015-06-01

    Emergy analysis is effective for analyzing ecological economic systems. However, the accuracy of the approach is affected by the diversity of economic level, meteorological and hydrological parameters in different regions. The present study evaluated the economic benefits, environmental impact, and sustainability of indoor, semi-intensive and extensive farming systems of sea cucumber ( Apostichopus japonicus) in the same region. The results showed that A. japonicus indoor farming system was high in input and output (yield) whereas pond extensive farming system was low in input and output. The output/input ratio of indoor farming system was lower than that of pond extensive farming system, and the output/input ratio of semi-intensive farming system fell in between them. The environmental loading ratio of A. japonicus extensive farming system was lower than that of indoor farming system. In addition, the emergy yield and emergy exchange ratios, and emergy sustainability and emergy indexes for sustainable development were higher in extensive farming system than those in indoor farming system. These results indicated that the current extensive farming system exerted fewer negative influences on the environment, made more efficient use of available resources, and met more sustainable development requirements than the indoor farming system. A. japonicus farming systems showed more emergy benefits than fish farming systems. The pond farming systems of A. japonicus exploited more free local environmental resources for production, caused less potential pressure on the local environment, and achieved higher sustainability than indoor farming system.

  11. Indoor PM2.5 in an urban zone with heavy wood smoke pollution: The case of Temuco, Chile.

    PubMed

    Jorquera, Héctor; Barraza, Francisco; Heyer, Johanna; Valdivia, Gonzalo; Schiappacasse, Luis N; Montoya, Lupita D

    2018-05-01

    Temuco is a mid-size city representative of severe wood smoke pollution in southern Chile; however, little is known about the indoor air quality in this region. A field measurement campaign at 63 households in the Temuco urban area was conducted in winter 2014 and is reported here. In this study, indoor and outdoor (24-hr) PM 2.5 and its elemental composition were measured and compared. Infiltration parameters and outdoor/indoor contributions to indoor PM 2.5 were also determined. A statistical evaluation of how various air quality interventions and household features influence indoor PM 2.5 was also performed. This study determined median indoor and outdoor PM 2.5 concentrations of 44.4 and 41.8 μg/m 3 , respectively. An average infiltration factor (0.62 ± 0.06) was estimated using sulfur as a tracer species. Using a simple mass balance approach, median indoor and outdoor contributions to indoor PM 2.5 concentrations were then estimated as 12.5 and 26.5 μg/m 3 , respectively; therefore, 68% of indoor PM 2.5 comes from outdoor infiltration. This high percentage is due to high outdoor pollution and relatively high household air exchange rates (median: 1.06 h -1 ). This study found that S, Br and Rb were dominated by outdoor contributions, while Si, Ca, Ti, Fe and As originated from indoor sources. Using continuous indoor and outdoor PM 2.5 measurements, a median indoor source strength of 75 μg PM 2.5 /min was estimated for the diurnal period, similar to literature results. For the evening period, the median estimate rose to 135 μg PM 2.5 /min, reflecting a more intense wood burning associated to cooking and space heating at night. Statistical test results (at the 90% confidence level) support the ongoing woodstove replacement program (reducing emissions) and household weatherization subsidies (reducing heating demand) for improving indoor air quality in southern Chile, and suggest that a cookstove improvement program might be helpful as well. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. An indoor chemical cocktail

    NASA Astrophysics Data System (ADS)

    Gligorovski, Sasho; Abbatt, Jonathan P. D.

    2018-02-01

    In the past 50 years, many of the contaminants and chemical transformations that occur in outdoor waters, soils, and air have been elucidated. However, the chemistry of the indoor environment in which we live most of the time—up to 90% in some societies—is not nearly as well studied. Recent work has highlighted the wealth of chemical transformations that occur indoors. This chemistry is associated with 3 of the top 10 risk factors for negative health outcomes globally: household air pollution from solid fuels, tobacco smoking, and ambient particulate matter pollution (1). Assessments of human exposure to indoor pollutants must take these reactive processes into consideration.

  13. Reactive indoor air chemistry and health-A workshop summary.

    PubMed

    Wells, J R; Schoemaecker, C; Carslaw, N; Waring, M S; Ham, J E; Nelissen, I; Wolkoff, P

    2017-11-01

    The chemical composition of indoor air changes due to the reactive nature of the indoor environment. Historically, only the stable parent compounds were investigated due to their ease of measurement by conventional methods. Today, however, scientists can better characterize oxidation products (gas and particulate-phase) formed by indoor chemistry. An understanding of occupant exposure can be developed through the investigation of indoor oxidants, the use of derivatization techniques, atmospheric pressure detection, the development of real-time technologies, and improved complex modeling techniques. Moreover, the connection between exposure and health effects is now receiving more attention from the research community. Nevertheless, a need still exists for improved understanding of the possible link between indoor air chemistry and observed acute or chronic health effects and long-term effects such as work-related asthma. Published by Elsevier GmbH.

  14. Concentrations of polybrominated diphenyl ethers (PBDEs) in central air-conditioner filter dust and relevance of non-dietary exposure in occupational indoor environments in Greece.

    PubMed

    Besis, Athanasios; Katsoyiannis, Athanasios; Botsaropoulou, Elisavet; Samara, Constantini

    2014-05-01

    Polybrominated Diphenyl Ethers (PBDEs) are ubiquitous in the indoor environment owing to their use in consumer products and various studies around the world have found higher concentrations indoors than outdoors. Central air conditioner (A/C) systems have been widely used in many workplaces, therefore, studying of PBDEs in central A/C filter dust is useful to better understand the occurrences and health implications of PBDEs in indoor environments. The present study examined the occurrence of PBDEs in central A/C filter dust collected from various workplaces (n = 20) in Thessaloniki, Greece. The sum concentrations of 21 target congeners (∑21PBDE) in A/C dust ranged between 84 and 4062 ng g(-1) with a median value of 1092 ng g(-1), while BDE-209 was found to be the most abundant BDE congener. The daily intake via dust ingestion of PBDEs estimated for the employees of the occupational settings ranged from 3 to 45 ng day(-1) (median 12 ng day(-1)). Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Antifungal properties of essential oils for improvement of indoor air quality: a review.

    PubMed

    Whiley, Harriet; Gaskin, Sharyn; Schroder, Tiffany; Ross, Kirstin

    2018-03-28

    Concerns regarding indoor air quality, particularly the presence of fungi and moulds, are increasing. The potential for essential oils to reduce, control or remove fungi, is gaining interest as they are seen as a "natural" alternative to synthetic chemical fungicides. This review examines published research on essential oils as a method of fungal control in indoor environments. It was difficult to compare the relative performances of essential oils due to differences in research methods and reporting languages. In addition, there are limited studies that scale up laboratory results and assess the efficacy of essential oils within building environments. However, generally, there appears to be some evidence to support the essential oils clove oil, tea tree oil, oregano, thyme and lemon as potential antifungal agents. Essential oils from heartwood, marjoram, cinnamon, lemon basil, caraway, bay tree, fir, peppermint, pine, cedar leaf and manuka were identified in at least one study as having antifungal potential. Future studies should focus on comparing the effectiveness of these essential oils against a large number of fungal isolates from indoor environments. Studies will then need to focus on translating these results into realistic application methods, in actual buildings, and assess the potential for long-term antifungal persistence.

  16. A positive chemical ionization GC/MS method for the determination of airborne ethylene glycol and propylene glycols in non-occupational environments.

    PubMed

    Zhu, Jiping; Feng, Yong-Lai; Aikawa, Bio

    2004-11-01

    An analytical method for ethylene glycol and propylene glycols has been developed for measuring airborne levels of these chemicals in non-occupational environments such as residences and office buildings. The analytes were collected on charcoal tubes, solvent extracted, and analyzed by gas chromatography-mass spectrometry using a positive chemical ionization technique. The method had a method detection limit of 0.07 microg m(-3) for ethylene glycol and 0.03 microg m(-3) for 1,2- and 1,3-propylene glycols, respectively, based on a 1.44 m3 sampling volume. Indoor air samples of several residential homes and other indoor environments have been analyzed. The median concentrations of ethylene glycol and 1,2-propylene glycol in nine residential indoor air samples were 53 microg m(-3) and 13 microg m(-3) respectively with maximum values of 223 microg m(-3) and 25 microg m(-3) detected for ethylene glycol and 1,2-propylene glycol respectively. The concentrations of these two chemicals in one office and two laboratories were at low microg m(-3) levels. The maximum concentration of 1,3-propylene glycol detected in indoor air was 0.1 microg m(-3).

  17. Guidance for Clinicians on the Recognition and Management of Health Effects Related to Mold Exposure and Moisture Indoors

    EPA Pesticide Factsheets

    The Guide for Clinicians was designed to help the healthcare provider address patients with illnesses related to mold in the indoor environment by providing background understanding of how mold may be affecting patients.

  18. A Mandate for Change in the Library Environment.

    ERIC Educational Resources Information Center

    Silberman, Richard M.

    1993-01-01

    The problem of indoor air quality and sick-building syndrome in libraries is explained in terms of human health and comfort and the preservation of books and manuscripts. Ventilation and indoor pollutants are discussed, and a proactive strategy of prevention is recommended. (EAM)

  19. Secondhand Tobacco Smoke and Smoke-free Homes

    MedlinePlus

    ... asthma trigger. Eliminating secondhand smoke from the indoor environment will improve the indoor air quality. View the 1992 EPA Risk Assessment (PDF) (525 pp, 4 MB, About PDF ) , U.S. EPA, Office of Research and Development, Office of Health and Environmental Assessment, Washington, DC, ...

  20. Occurrence, sources and human exposure assessment of SCCPs in indoor dust of northeast China.

    PubMed

    Liu, Li-Hua; Ma, Wan-Li; Liu, Li-Yan; Huo, Chun-Yan; Li, Wen-Long; Gao, Chong-Jing; Li, Hai-Ling; Li, Yi-Fan; Chan, Hing Man

    2017-06-01

    Short-chain chlorinated paraffins (SCCPs) are widely used chemicals in household products and might cause adverse human health effects. However, limited information is available on the occurrence of SCCPs in indoor environments and their exposure risks on humans. In this study the concentrations, profiles and human exposure of SCCPs in indoor dust from five different indoor environments, including commercial stores, residential apartments, dormitories, offices and laboratories were characterized. The SCCPs levels ranged from 10.1 to 173.0 μg/g, with the median and mean concentration of 47.2 and 53.6 μg/g, respectively. No significant difference was found on concentrations among the five microenvironments. The most abundant compounds in indoor dust samples were homologues of C 13 group, Cl 7 group and N 20 (N is the total number of C and Cl) group. In the five microenvironments, commercial stores were more frequently exposed to shorter carbon chained and higher chlorinated homologues. Three potential sources for SCCPs were identified by the multiple linear regression of factor score model and correspondence analysis. The major sources of SCCPs in indoor dust were technical mixtures of CP-42 (42% chlorine, w/w) and CP-52 b (52% chlorine, w/w). The total daily exposure doses and hazard quotients (HQ) were calculated by the human exposure models, and they were all below the reference doses and threshold values, respectively. Monte Carlo simulation was applied to predict the human exposure risk of SCCPs. Infants and toddlers were at risk of SCCPs based on predicted HQ values, which were exceeded the threshold for neoplastic effects in the worst case. Our results on the occurrences, sources and human exposures of SCCPs will be useful to provide a better understanding of SCCPs behaviors in indoor environment in China, and to support environmental risk evaluation and regulation of SCCPs in the world. Copyright © 2017. Published by Elsevier Ltd.

  1. The analysis of thermal comfort requirements through the simulation of an occupied building.

    PubMed

    Thellier, F; Cordier, A; Monchoux, F

    1994-05-01

    Building simulation usually focuses on the study of physical indoor parameters, but we must not forget the main aim of a house: to provide comfort to the occupants. This study was undertaken in order to build a complete tool to model thermal behaviour that will enable the prediction of thermal sensations of humans in a real environment. A human thermoregulation model was added to TRNSYS, a building simulation program. For our purposes, improvements had to be made to the original physiological model, by refining the calculation of all heat exchanges with the environment and adding a representation of clothes. This paper briefly describes the program, its modifications, and compares its results with experimental ones. An example of potential use is given, which points out the usefulness of such models in seeking the best solutions to reach optimal environmental conditions for global, and specially local comfort, of building occupants.

  2. Design and Implementation of a Smart Home System Using Multisensor Data Fusion Technology.

    PubMed

    Hsu, Yu-Liang; Chou, Po-Huan; Chang, Hsing-Cheng; Lin, Shyan-Lung; Yang, Shih-Chin; Su, Heng-Yi; Chang, Chih-Chien; Cheng, Yuan-Sheng; Kuo, Yu-Chen

    2017-07-15

    This paper aims to develop a multisensor data fusion technology-based smart home system by integrating wearable intelligent technology, artificial intelligence, and sensor fusion technology. We have developed the following three systems to create an intelligent smart home environment: (1) a wearable motion sensing device to be placed on residents' wrists and its corresponding 3D gesture recognition algorithm to implement a convenient automated household appliance control system; (2) a wearable motion sensing device mounted on a resident's feet and its indoor positioning algorithm to realize an effective indoor pedestrian navigation system for smart energy management; (3) a multisensor circuit module and an intelligent fire detection and alarm algorithm to realize a home safety and fire detection system. In addition, an intelligent monitoring interface is developed to provide in real-time information about the smart home system, such as environmental temperatures, CO concentrations, communicative environmental alarms, household appliance status, human motion signals, and the results of gesture recognition and indoor positioning. Furthermore, an experimental testbed for validating the effectiveness and feasibility of the smart home system was built and verified experimentally. The results showed that the 3D gesture recognition algorithm could achieve recognition rates for automated household appliance control of 92.0%, 94.8%, 95.3%, and 87.7% by the 2-fold cross-validation, 5-fold cross-validation, 10-fold cross-validation, and leave-one-subject-out cross-validation strategies. For indoor positioning and smart energy management, the distance accuracy and positioning accuracy were around 0.22% and 3.36% of the total traveled distance in the indoor environment. For home safety and fire detection, the classification rate achieved 98.81% accuracy for determining the conditions of the indoor living environment.

  3. Seasonal and diurnal variability in airborne mold from an indoor residential environment in northern New York.

    PubMed

    LeBouf, Ryan; Yesse, Liesel; Rossner, Alan

    2008-05-01

    It is well known that characterization of airborne bioaerosols in indoor environments is a challenge because of inherent irregularity in concentrations, which are influenced by many environmental factors. The primary aim of this study was to quantify the day-to-day variability of airborne fungal levels in a single residential environment over multiple seasons. Indoor air quality practitioners must recognize the inherent variability in airborne bio-aerosol measurements during data analysis of mold investigations. Changes in airborne fungi due to varying season and day is important to recognize when considering health impacts of these contaminants and when establishing effective controls. Using an Andersen N6 impactor, indoor and outdoor bioaerosol samples were collected on malt extract agar plates for 18 weekdays and 19 weekdays in winter and summer, respectively. Interday and intraday variability for the bioaerosols were determined for each sampler. Average fungal concentrations were 26 times higher during the summer months. Day-to-day fungal samples showed a relatively high inconsistency suggesting airborne fungal levels are very episodic and are influenced by several environmental factors. Summer bio-aerosol variability ranged from 7 to 36% and winter variability from 24 to 212%; these should be incorporated into results of indoor mold investigations. The second objective was to observe the relationship between biological and nonbiological particulate matter (PM). No correlation was observed between biological and nonbiological PM. Six side-by-side particulate samplers collected coarse PM (PM10) and fine PM (PM2.5) levels in both seasons. PM2.5 particulate concentrations were found to be statistically higher during summer months. Interday variability observed during this study suggests that indoor air quality practitioners must adjust their exposure assessment strategies to reflect the temporal variability in bioaerosol concentrations.

  4. Design and Implementation of a Smart Home System Using Multisensor Data Fusion Technology

    PubMed Central

    Chou, Po-Huan; Chang, Hsing-Cheng; Lin, Shyan-Lung; Yang, Shih-Chin; Su, Heng-Yi; Chang, Chih-Chien; Cheng, Yuan-Sheng; Kuo, Yu-Chen

    2017-01-01

    This paper aims to develop a multisensor data fusion technology-based smart home system by integrating wearable intelligent technology, artificial intelligence, and sensor fusion technology. We have developed the following three systems to create an intelligent smart home environment: (1) a wearable motion sensing device to be placed on residents’ wrists and its corresponding 3D gesture recognition algorithm to implement a convenient automated household appliance control system; (2) a wearable motion sensing device mounted on a resident’s feet and its indoor positioning algorithm to realize an effective indoor pedestrian navigation system for smart energy management; (3) a multisensor circuit module and an intelligent fire detection and alarm algorithm to realize a home safety and fire detection system. In addition, an intelligent monitoring interface is developed to provide in real-time information about the smart home system, such as environmental temperatures, CO concentrations, communicative environmental alarms, household appliance status, human motion signals, and the results of gesture recognition and indoor positioning. Furthermore, an experimental testbed for validating the effectiveness and feasibility of the smart home system was built and verified experimentally. The results showed that the 3D gesture recognition algorithm could achieve recognition rates for automated household appliance control of 92.0%, 94.8%, 95.3%, and 87.7% by the 2-fold cross-validation, 5-fold cross-validation, 10-fold cross-validation, and leave-one-subject-out cross-validation strategies. For indoor positioning and smart energy management, the distance accuracy and positioning accuracy were around 0.22% and 3.36% of the total traveled distance in the indoor environment. For home safety and fire detection, the classification rate achieved 98.81% accuracy for determining the conditions of the indoor living environment. PMID:28714884

  5. Impact of Indoor Physical Environment on Learning Efficiency in Different Types of Tasks: A 3 × 4 × 3 Full Factorial Design Analysis.

    PubMed

    Xiong, Lilin; Huang, Xiao; Li, Jie; Mao, Peng; Wang, Xiang; Wang, Rubing; Tang, Meng

    2018-06-13

    Indoor physical environments appear to influence learning efficiency nowadays. For improvement in learning efficiency, environmental scenarios need to be designed when occupants engage in different learning tasks. However, how learning efficiency is affected by indoor physical environment based on task types are still not well understood. The present study aims to explore the impacts of three physical environmental factors (i.e., temperature, noise, and illuminance) on learning efficiency according to different types of tasks, including perception, memory, problem-solving, and attention-oriented tasks. A 3 × 4 × 3 full factorial design experiment was employed in a university classroom with 10 subjects recruited. Environmental scenarios were generated based on different levels of temperature (17 °C, 22 °C, and 27 °C), noise (40 dB(A), 50 dB(A), 60 dB(A), and 70 dB(A)) and illuminance (60 lx, 300 lx, and 2200 lx). Accuracy rate (AC), reaction time (RT), and the final performance indicator (PI) were used to quantify learning efficiency. The results showed ambient temperature, noise, and illuminance exerted significant main effect on learning efficiency based on four task types. Significant concurrent effects of the three factors on final learning efficiency was found in all tasks except problem-solving-oriented task. The optimal environmental scenarios for top learning efficiency were further identified under different environmental interactions. The highest learning efficiency came in thermoneutral, relatively quiet, and bright conditions in perception-oriented task. Subjects performed best under warm, relatively quiet, and moderately light exposure when recalling images in the memory-oriented task. Learning efficiency peaked to maxima in thermoneutral, fairly quiet, and moderately light environment in problem-solving process while in cool, fairly quiet and bright environment with regard to attention-oriented task. The study provides guidance for building users to conduct effective environmental intervention with simultaneous controls of ambient temperature, noise, and illuminance. It contributes to creating the most suitable indoor physical environment for improving occupants learning efficiency according to different task types. The findings could further supplement the present indoor environment-related standards or norms with providing empirical reference on environmental interactions.

  6. Climate change and health: Indoor heat exposure in vulnerable populations☆

    PubMed Central

    White-Newsome, Jalonne L.; Sánchez, Brisa N.; Jolliet, Olivier; Zhang, Zhenzhen; Parker, Edith A.; Dvonch, J. Timothy; O'Neill, Marie S.

    2015-01-01

    Introduction Climate change is increasing the frequency of heat waves and hot weather in many urban environments. Older people are more vulnerable to heat exposure but spend most of their time indoors. Few published studies have addressed indoor heat exposure in residences occupied by an elderly population. The purpose of this study is to explore the relationship between outdoor and indoor temperatures in homes occupied by the elderly and determine other predictors of indoor temperature. Materials and methods We collected hourly indoor temperature measurements of 30 different homes; outdoor temperature, dewpoint temperature, and solar radiation data during summer 2009 in Detroit, MI. We used mixed linear regression to model indoor temperatures’ responsiveness to weather, housing and environmental characteristics, and evaluated our ability to predict indoor heat exposures based on outdoor conditions. Results Average maximum indoor temperature for all locations was 34.85 °C, 13.8 °C higher than average maximum outdoor temperature. Indoor temperatures of single family homes constructed of vinyl paneling or wood siding were more sensitive than brick homes to outdoor temperature changes and internal heat gains. Outdoor temperature, solar radiation, and dewpoint temperature predicted 38% of the variability of indoor temperatures. Conclusions Indoor exposures to heat in Detroit exceed the comfort range among elderly occupants, and can be predicted using outdoor temperatures, characteristics of the housing stock and surroundings PMID:22071034

  7. Occurrence of endocrine-disrupting chemicals in indoor dust

    PubMed Central

    Hwang, Hyun-Min; Park, Eun-Kee; Young, Thomas M.; Hammock, Bruce D.

    2010-01-01

    Human exposure to indoor dust enriched with endocrine-disrupting chemicals released from numerous indoor sources has been a focus of increasing concern. Longer residence times and elevated contaminant concentrations in the indoor environment may increase chances of exposure to these contaminants by 1000-fold compared to outdoor exposure. To investigate the occurrence of semi-volatile endocrine-disrupting chemicals, including PBDEs (polybrominated diphenyl ethers), PCBs (polychlorinated biphenyls), phthalates, pyrethroids, DDT (dichlorodiphenyltrichloroethane) and its metabolites, and chlordanes, indoor dust samples were collected from household vacuum cleaner bags provided by 10 apartments and 1 community hall in Davis, California, USA. Chemical analyses show that all indoor dust samples are highly contaminated by target analytes measured in the present study. Di-(2-ethylhexyl)phthalate was the most abundant (104–7630 μg/g) in all samples and higher than other target analytes by 2 to 6 orders of magnitude. PBDEs were also found at high concentrations (1780–25,200 ng/g). Although the use of PCBs has been banned or restricted for decades, some samples had PCBs at levels that are considered to be concerns for human health, indicating that the potential risk posed by PCBs still remains high in the indoor environment, probably due to a lack of dissipation processes and continuous release from the sources. Although the use of some PBDEs is being phased out in some parts of the U.S., this trend may apply to PBDEs as well. We can anticipate that exposure to PBDEs will continue as long as the general public keeps using existing household items such as sofas, mattresses, and carpets that contain PBDEs. This study provides additional information that indoor dust is highly contaminated by persistent and endocrine-disrupting chemicals. PMID:18632138

  8. Comparative assessment of a real-time particle monitor against the reference gravimetric method for PM10 and PM2.5 in indoor air

    NASA Astrophysics Data System (ADS)

    Tasić, Viša; Jovašević-Stojanović, Milena; Vardoulakis, Sotiris; Milošević, Novica; Kovačević, Renata; Petrović, Jelena

    2012-07-01

    Accurate monitoring of indoor mass concentrations of particulate matter is very important for health risk assessment as people in developed countries spend approximately 90% of their time indoors. The direct reading, aerosol monitoring device, Turnkey, OSIRIS Particle Monitor (Model 2315) and the European reference low volume sampler, LVS3 (Sven/Leckel LVS3) with size-selective inlets for PM10 and PM2.5 fractions were used to assess the comparability of available optical and gravimetric methods for particulate matter characterization in indoor air. Simultaneous 24-hour samples were collected in an indoor environment for 60 sampling periods in the town of Bor, Serbia. The 24-hour mean PM10 levels from the OSIRIS monitor were well correlated with the LVS3 levels (R2 = 0.87) and did not show statistically significant bias. The 24-hour mean PM2.5 levels from the OSIRIS monitor were moderately correlated with the LVS3 levels (R2 = 0.71), but show statistically significant bias. The results suggest that the OSIRIS monitor provides sufficiently accurate measurements for PM10. The OSIRIS monitor underestimated the indoor PM10 concentrations by approximately 12%, relative to the reference LVS3 sampler. The accuracy of PM10 measurements could be further improved through empirical adjustment. For the fine fraction of particulate matter, PM2.5, it was found that the OSIRIS monitor underestimated indoor concentrations by approximately 63%, relative to the reference LVS3 sampler. This could lead to exposure misclassification in health effects studies relying on PM2.5 measurements collected with this instrument in indoor environments.

  9. Phthalate and non-phthalate plasticizers in indoor dust from childcare facilities, salons, and homes across the USA.

    PubMed

    Subedi, Bikram; Sullivan, Kenneth D; Dhungana, Birendra

    2017-11-01

    The quality of indoor environment has received considerable attention owing to the declining outdoor human activities and the associated public health issues. The prolonged exposure of children in childcare facilities or the occupational exposure of adults to indoor environmental triggers can be a culprit of the pathophysiology of several commonly observed idiopathic syndromes. In this study, concentrations of potentially toxic plasticizers (phthalates as well as non-phthalates) were investigated in 28 dust samples collected from three different indoor environments across the USA. The mean concentrations of non-phthalate plasticizers [acetyl tri-n-butyl citrate (ATBC), di-(2-ethylhexyl) adipate (DEHA), and di-isobutyl adipate (DIBA)] were found at 0.51-880 μg/g for the first time in indoor dust samples from childcare facilities, homes, and salons across the USA. The observed concentrations of these replacement non-phthalate plasticizer were as high as di-(2-ethylhexyl) phthalate, the most frequently detected phthalate plasticizer at highest concentration worldwide, in most of indoor dust samples. The estimated daily intakes of total phthalates (n = 7) by children and toddlers through indoor dust in childcare facilities were 1.6 times higher than the non-phthalate plasticizers (n = 3), whereas estimated daily intake of total non-phthalates for all age groups at homes were 1.9 times higher than the phthalate plasticizers. This study reveals, for the first time, a more elevated (∼3 folds) occupational intake of phthalate and non-phthalate plasticizers through the indoor dust at salons (214 and 285 ng/kg-bw/day, respectively) than at homes in the USA. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Object Detection Applied to Indoor Environments for Mobile Robot Navigation.

    PubMed

    Hernández, Alejandra Carolina; Gómez, Clara; Crespo, Jonathan; Barber, Ramón

    2016-07-28

    To move around the environment, human beings depend on sight more than their other senses, because it provides information about the size, shape, color and position of an object. The increasing interest in building autonomous mobile systems makes the detection and recognition of objects in indoor environments a very important and challenging task. In this work, a vision system to detect objects considering usual human environments, able to work on a real mobile robot, is developed. In the proposed system, the classification method used is Support Vector Machine (SVM) and as input to this system, RGB and depth images are used. Different segmentation techniques have been applied to each kind of object. Similarly, two alternatives to extract features of the objects are explored, based on geometric shape descriptors and bag of words. The experimental results have demonstrated the usefulness of the system for the detection and location of the objects in indoor environments. Furthermore, through the comparison of two proposed methods for extracting features, it has been determined which alternative offers better performance. The final results have been obtained taking into account the proposed problem and that the environment has not been changed, that is to say, the environment has not been altered to perform the tests.

  11. Object Detection Applied to Indoor Environments for Mobile Robot Navigation

    PubMed Central

    Hernández, Alejandra Carolina; Gómez, Clara; Crespo, Jonathan; Barber, Ramón

    2016-01-01

    To move around the environment, human beings depend on sight more than their other senses, because it provides information about the size, shape, color and position of an object. The increasing interest in building autonomous mobile systems makes the detection and recognition of objects in indoor environments a very important and challenging task. In this work, a vision system to detect objects considering usual human environments, able to work on a real mobile robot, is developed. In the proposed system, the classification method used is Support Vector Machine (SVM) and as input to this system, RGB and depth images are used. Different segmentation techniques have been applied to each kind of object. Similarly, two alternatives to extract features of the objects are explored, based on geometric shape descriptors and bag of words. The experimental results have demonstrated the usefulness of the system for the detection and location of the objects in indoor environments. Furthermore, through the comparison of two proposed methods for extracting features, it has been determined which alternative offers better performance. The final results have been obtained taking into account the proposed problem and that the environment has not been changed, that is to say, the environment has not been altered to perform the tests. PMID:27483264

  12. Fully distributed monitoring architecture supporting multiple trackees and trackers in indoor mobile asset management application.

    PubMed

    Jeong, Seol Young; Jo, Hyeong Gon; Kang, Soon Ju

    2014-03-21

    A tracking service like asset management is essential in a dynamic hospital environment consisting of numerous mobile assets (e.g., wheelchairs or infusion pumps) that are continuously relocated throughout a hospital. The tracking service is accomplished based on the key technologies of an indoor location-based service (LBS), such as locating and monitoring multiple mobile targets inside a building in real time. An indoor LBS such as a tracking service entails numerous resource lookups being requested concurrently and frequently from several locations, as well as a network infrastructure requiring support for high scalability in indoor environments. A traditional centralized architecture needs to maintain a geographic map of the entire building or complex in its central server, which can cause low scalability and traffic congestion. This paper presents a self-organizing and fully distributed indoor mobile asset management (MAM) platform, and proposes an architecture for multiple trackees (such as mobile assets) and trackers based on the proposed distributed platform in real time. In order to verify the suggested platform, scalability performance according to increases in the number of concurrent lookups was evaluated in a real test bed. Tracking latency and traffic load ratio in the proposed tracking architecture was also evaluated.

  13. Neural computing thermal comfort index PMV for the indoor environment intelligent control system

    NASA Astrophysics Data System (ADS)

    Liu, Chang; Chen, Yifei

    2013-03-01

    Providing indoor thermal comfort and saving energy are two main goals of indoor environmental control system. An intelligent comfort control system by combining the intelligent control and minimum power control strategies for the indoor environment is presented in this paper. In the system, for realizing the comfort control, the predicted mean vote (PMV) is designed as the control goal, and with chastening formulas of PMV, it is controlled to optimize for improving indoor comfort lever by considering six comfort related variables. On the other hand, a RBF neural network based on genetic algorithm is designed to calculate PMV for better performance and overcoming the nonlinear feature of the PMV calculation better. The formulas given in the paper are presented for calculating the expected output values basing on the input samples, and the RBF network model is trained depending on input samples and the expected output values. The simulation result is proved that the design of the intelligent calculation method is valid. Moreover, this method has a lot of advancements such as high precision, fast dynamic response and good system performance are reached, it can be used in practice with requested calculating error.

  14. Endotoxins in indoor air and settled dust in primary schools in a subtropical climate.

    PubMed

    Salonen, Heidi; Duchaine, Caroline; Létourneau, Valérie; Mazaheri, Mandana; Clifford, Sam; Morawska, Lidia

    2013-09-03

    Endotoxins can significantly affect the air quality in school environments. However, there is currently no reliable method for the measurement of endotoxins, and there is a lack of reference values for endotoxin concentrations to aid in the interpretation of measurement results in school settings. We benchmarked the "baseline" range of endotoxin concentration in indoor air, together with endotoxin load in floor dust, and evaluated the correlation between endotoxin levels in indoor air and settled dust, as well as the effects of temperature and humidity on these levels in subtropical school settings. Bayesian hierarchical modeling indicated that the concentration in indoor air and the load in floor dust were generally (<95th percentile) <13 EU/m(3) and <24,570 EU/m(2), respectively. Exceeding these levels would indicate abnormal sources of endotoxins in the school environment and the need for further investigation. Metaregression indicated no relationship between endotoxin concentration and load, which points to the necessity for measuring endotoxin levels in both the air and settled dust. Temperature increases were associated with lower concentrations in indoor air and higher loads in floor dust. Higher levels of humidity may be associated with lower airborne endotoxin concentrations.

  15. Allergens in indoor air: environmental assessment and health effects.

    PubMed

    Carrer, P; Maroni, M; Alcini, D; Cavallo, D

    2001-04-10

    It has been suggested that the increase in morbidity and mortality for asthma and allergies, may also be due to an increase in exposure to allergens in the modern indoor environment. Indoor allergen exposure is recognised as the most important risk factor for asthma in children. House dust mites, pets, insects, plants, moulds and chemical agents in the indoor environment are important causes of allergic diseases. House dust mites and their debris and excrements that contain the allergens are normally found in the home in beds, mattresses, pillows, carpets and furniture stuffing, but they have also been found in office environments. Domestic animals such as cats, dogs, birds and rodents may cause allergic asthma and rhinoconjunctivitis. The exposure usually occurs in homes, but also in schools and kindergartens where domestic animals are kept as pets or for education; moreover, cat and dog owners can bring allergens to public areas in their clothes. Allergy to natural rubber latex has become an important occupational health concern in recent years, particularly among healthcare workers; when powdered gloves are worn or changed, latex particles get into the air and workers are exposed to latex aerosolised antigens. To assess the environmental risk to allergen exposure or to verify if there is a causal relationship between the immunologic findings in a patient and his/her environmental exposure, sampling from the suspected environment may be necessary.

  16. Molds and mycotoxins in indoor environments--a survey in water-damaged buildings.

    PubMed

    Bloom, Erica; Nyman, Eva; Must, Aime; Pehrson, Christina; Larsson, Lennart

    2009-11-01

    Mycotoxins are toxic, secondary metabolites frequently produced by molds in water-damaged indoor environments. We studied the prevalence of selected, potent mycotoxins and levels of fungal biomass in samples collected from water-damaged indoor environments in Sweden during a 1-year period. One hundred samples of building materials, 18 samples of settled dust, and 37 samples of cultured dust were analyzed for: (a) mycoflora by microscopy and culture; (b) fungal chemical marker ergosterol and hydrolysis products of macrocyclic trichothecenes and trichodermin (verrucarol and trichodermol) by gas chromatography-tandem mass spectrometry; and (c) sterigmatocystin, gliotoxin, aflatoxin B(1), and satratoxin G and H by high performance liquid chromatography-tandem mass spectrometry. Sixty-six percent of the analyzed building materials samples, 11% of the settled dust samples, and 51% of the cultured dust samples were positive for at least one of the studied mycotoxins. In addition, except in the case of gliotoxin, mycotoxin-positive building material samples contained 2-6 times more ergosterol than mycotoxin-negative samples. We show that (a) molds growing on a range of different materials indoors in water-damaged buildings generally produce mycotoxins, and (b) mycotoxin-containing particles in mold-contaminated environments may settle on surfaces above floor level. The mass spectrometry methods used in this study are valuable tools in further research to survey mycotoxin exposure and investigate potential links with health effects.

  17. A flexible routing scheme for patients with topographical disorientation.

    PubMed

    Torres-Solis, Jorge; Chau, Tom

    2007-11-28

    Individuals with topographical disorientation have difficulty navigating through indoor environments. Recent literature has suggested that ambient intelligence technologies may provide patients with navigational assistance through auditory or graphical instructions delivered via embedded devices. We describe an automatic routing engine for such an ambient intelligence system. The method routes patients with topographical disorientation through indoor environments by repeatedly computing the route of minimal cost from the current location of the patient to a specified destination. The cost of a given path not only reflects the physical distance between end points, but also incorporates individual patient abilities, the presence of mobility-impeding physical barriers within a building and the dynamic nature of the indoor environment. We demonstrate the method by routing simulated patients with either topographical disorientation or physical disabilities. Additionally, we exemplify the ability to route a patient from source to destination while taking into account changes to the building interior. When compared to a random walk, the proposed routing scheme offers potential cost-savings even when the patient follows only a subset of instructions. The routing method presented reduces the navigational effort for patients with topographical disorientation in indoor environments, accounting for physical abilities of the patient, environmental barriers and dynamic building changes. The routing algorithm and database proposed could be integrated into wearable and mobile platforms within the context of an ambient intelligence solution.

  18. On-body calibration and measurements using personal radiofrequency exposimeters in indoor diffuse and specular environments.

    PubMed

    Aminzadeh, Reza; Thielens, Arno; Bamba, Aliou; Kone, Lamine; Gaillot, Davy Paul; Lienard, Martine; Martens, Luc; Joseph, Wout

    2016-07-01

    For the first time, response of personal exposimeters (PEMs) is studied under diffuse field exposure in indoor environments. To this aim, both numerical simulations, using finite-difference time-domain method, and calibration measurements were performed in the range of 880-5875 MHz covering 10 frequency bands in Belgium. Two PEMs were mounted on the body of a human male subject and calibrated on-body in an anechoic chamber (non-diffuse) and a reverberation chamber (RC) (diffuse fields). This was motivated by the fact that electromagnetic waves in indoor environments have both specular and diffuse components. Both calibrations show that PEMs underestimate actual incident electromagnetic fields. This can be compensated by using an on-body response. Moreover, it is shown that these responses are different in anechoic chamber and RC. Therefore, it is advised to use an on-body calibration in an RC in future indoor PEM measurements where diffuse fields are present. Using the response averaged over two PEMs reduced measurement uncertainty compared to single PEMs. Following the calibration, measurements in a realistic indoor environment were done for wireless fidelity (WiFi-5G) band. Measured power density values are maximally 8.9 mW/m(2) and 165.8 μW/m(2) on average. These satisfy reference levels issued by the International Commission on Non-Ionizing Radiation Protection in 1998. Power density values obtained by applying on-body calibration in RC are higher than values obtained from no body calibration (only PEMs) and on-body calibration in anechoic room, by factors of 7.55 and 2.21, respectively. Bioelectromagnetics. 37:298-309, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  19. Particulate matter concentrations and their related metal toxicity in rural residential environment of semi-arid region of India

    NASA Astrophysics Data System (ADS)

    Massey, David D.; Kulshrestha, Aditi; Taneja, Ajay

    2013-03-01

    The concentration of PM10, PM5.0, PM2.5 and PM1 were measured in the indoor-outdoor environment of rural homes of North central part of India during winter, summer and rainy seasons for the time duration of October 2007 to March 2009. Seven trace metals (Pb, Cd, Ni, Fe, Cr, Mn and Cu) were also determined in PM2.5 from October 2007 to March 2009 in the indoor-outdoor environment. During the study period the annual average concentration for PM10, PM5.0, PM2.5 and PM1 in indoor and outdoor were 242.53 μg m-3 and 217.76 μg m-3, 203.57 μg m-3 and 180.42 μg m-3, 164.60 μg m-3 and 143.07 μg m-3, 106.23 μg m-3 and 105.17 μg m-3 respectively. Concentrations of PM10 and PM2.5 have been compared with prescribed WHO standards and NAAQS standards of India and were found to be much higher. Significant seasonal variations of particulate pollutants were obtained using the monthly average concentration of coarse and fine particulate matter. Indoor/outdoor ratios at the rural sites were also determined with the meteorological parameters like temperature, humidity, wind speed and air exchange rate. Chromium was found to have the highest excess cancer risk in a risk evaluation using an Integrated Risk Information System. Three factors each in indoor and outdoor environment of rural site have been identified using Principal Component Analysis & Positive Matrix Factorization.

  20. POST-APPLICATION EXPOSURE POTENTIAL TO PESTICIDES IN THE RESIDENTIAL ENVIRONMENT

    EPA Science Inventory

    A study to investigate the temporal and spatial distributions of pesticides applied by homeowners and commercial applicators for indoor crack and crevice treatments was initiated by the U.S. EPA in 1999. In participating households, pre- and post-application samples of indoor ...

  1. MCEARD CONTRIBUTION TO ORD ASTHMA RESEARCH INITIATIVE

    EPA Science Inventory

    Beginning in 1998, EPA researchers have worked to examine the role of indoor molds/fungi in children's health. The make-up of the indoor environment is critical to the health of children in general and has a particularly important influence on the incidence and exacerbation of ...

  2. Indoor Residence Times of Semivolatile Organic Compounds: Model Estimation and Field Evaluation

    EPA Science Inventory

    Indoor residence times of semivolatile organic compounds (SVOCs) are a major and mostly unavailable input for residential exposure assessment. We calculated residence times for a suite of SVOCs using a fugacity model applied to residential environments. Residence times depend on...

  3. AN ANALYTICAL METHOD FOR THE MEASUREMENT OF NONVIABLE BIOAEROSOLS

    EPA Science Inventory

    Exposures from indoor environments are a major issue for evaluating total long-term personal exposure to the fine fraction (<2.5 micrometers in aerodynamic diameter) of particulate matter (PM). It is widely accepted in the indoor air quality (IAQ) research community that bioconta...

  4. Developing a Reference Material for Formaldehyde Emissions Testing; Final Report

    EPA Science Inventory

    Exposure to formaldehyde has been shown to produce broad and potentially severe adverse human health effects. With ubiquitous formaldehyde sources in the indoor environment, formaldehyde concentrations in indoor air are usually higher than outdoors, ranging from 10 to 4000 μg/m3....

  5. NLOS mitigation and ranging accuracy for building indoor positioning system in UWB using commercial radio modules

    NASA Astrophysics Data System (ADS)

    Alsudani, Ahlam

    2018-05-01

    In recent years, indoor positioning system (IPS) plays a very important role in several environments such as hospitals, airports, males, Etc. It is used to locate mobile stations such as human and robots inside buildings. Some of IPSs applications are: locating an elder or child needed for an urgent help in hospitals, emergency situations such as locating firefighters inside building on fire or policemen fitting terrorists inside building by a commander to help for expedite evacuation in case one of them need for help. In indoor positioning applications, the accuracy should be high as can as possible, in another word; the error should be less than 1 meter. The indoor environment is the major challenging to obtain such accuracy. In this paper, we present a novel algorithm to identify the line of sight (LOS) and non-line of sight (NLOS) channels and improve the positioning accuracy using ultra-wideband (UWB) technology implementing DW1000 devices.

  6. Indoor Pedestrian Navigation Using Foot-Mounted IMU and Portable Ultrasound Range Sensors

    PubMed Central

    Girard, Gabriel; Côté, Stéphane; Zlatanova, Sisi; Barette, Yannick; St-Pierre, Johanne; van Oosterom, Peter

    2011-01-01

    Many solutions have been proposed for indoor pedestrian navigation. Some rely on pre-installed sensor networks, which offer good accuracy but are limited to areas that have been prepared for that purpose, thus requiring an expensive and possibly time-consuming process. Such methods are therefore inappropriate for navigation in emergency situations since the power supply may be disturbed. Other types of solutions track the user without requiring a prepared environment. However, they may have low accuracy. Offline tracking has been proposed to increase accuracy, however this prevents users from knowing their position in real time. This paper describes a real time indoor navigation system that does not require prepared building environments and provides tracking accuracy superior to previously described tracking methods. The system uses a combination of four techniques: foot-mounted IMU (Inertial Motion Unit), ultrasonic ranging, particle filtering and model-based navigation. The very purpose of the project is to combine these four well-known techniques in a novel way to provide better indoor tracking results for pedestrians. PMID:22164034

  7. Modeling Human Exposure to Indoor Contaminants: External Source to Body Tissues.

    PubMed

    Webster, Eva M; Qian, Hua; Mackay, Donald; Christensen, Rebecca D; Tietjen, Britta; Zaleski, Rosemary

    2016-08-16

    Information on human indoor exposure is necessary to assess the potential risk to individuals from many chemicals of interest. Dynamic indoor and human physicologically based pharmacokinetic (PBPK) models of the distribution of nonionizing, organic chemical concentrations in indoor environments resulting in delivered tissue doses are developed, described and tested. The Indoor model successfully reproduced independently measured, reported time-dependent air concentrations of chloroform released during showering and of 2-butyoxyethanol following use of a volatile surface cleaner. The Indoor model predictions were also comparable to those from a higher tier consumer model (ConsExpo 4.1) for the surface cleaner scenario. The PBPK model successful reproduced observed chloroform exhaled air concentrations resulting from an inhalation exposure. Fugacity based modeling provided a seamless description of the partitioning, fluxes, accumulation and release of the chemical in indoor media and tissues of the exposed subject. This has the potential to assist in health risk assessments, provided that appropriate physical/chemical property, usage characteristics, and toxicological information are available.

  8. [Indoor volatile organic compounds: concentrations, sources, variation factors].

    PubMed

    Palot, A; Charpin-Kadouch, C; Ercoli, J; Charpin, D

    2008-06-01

    Volatile organic compounds (V.O.C.) are part of urban air pollution and are also generated indoors from cleaning and maintenance products. VOC measurements are, on average, 10 times higher within homes than outside. Results of the national survey led by the Observatoire National de la Qualité de l'Air Intérieur demonstrated that up to 25% of French homes have very high or high concentrations of VOC. Indoor levels depend mainly on indoor sources. Aldehydes are included in many everyday life products. VOC originate from various household decorating and cleaning products. Some products are less detrimental to the environment and health and have special labelling. Indoor VOC levels also depend on the rate of air exchange and on household characteristics such as indoor temperature and humidity, age of the building, presence of smokers, and communication with a garage. The public may participate in maintaining good indoor air quality and the authorities should also improve regulations. VOC are part of everyday air pollution. Their sources and concentrations should be better monitored.

  9. Field-to-laboratory analysis of clay wall coatings as passive removal materials for ozone in buildings.

    PubMed

    Darling, E; Corsi, R L

    2017-05-01

    Ozone reacts readily with many indoor materials, as well as with compounds in indoor air. These reactions lead to lower indoor than outdoor ozone concentrations when outdoor air is the major contributor to indoor ozone. However, the products of indoor ozone reactions may be irritating or harmful to building occupants. While active technologies exist to reduce indoor ozone concentrations (i.e, in-duct filtration using activated carbon), they can be cost-prohibitive for some and/or infeasible for dwellings that do not have heating, ventilating, and air-conditioning systems. In this study, the potential for passive reduction of indoor ozone by two different clay-based interior surface coatings was explored. These coatings were exposed to occupied residential indoor environments and tested bimonthly in environmental chambers for quantification of ozone reaction probabilities and reaction product emission rates over a 6-month period. Results indicate that clay-based coatings may be effective as passive removal materials, with relatively low by-product emission rates that decay rapidly within 2 months. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. NIAID, NIEHS, NHLBI, and MCAN Workshop Report: The indoor environment and childhood asthma-implications for home environmental intervention in asthma prevention and management.

    PubMed

    Gold, Diane R; Adamkiewicz, Gary; Arshad, Syed Hasan; Celedón, Juan C; Chapman, Martin D; Chew, Ginger L; Cook, Donald N; Custovic, Adnan; Gehring, Ulrike; Gern, James E; Johnson, Christine C; Kennedy, Suzanne; Koutrakis, Petros; Leaderer, Brian; Mitchell, Herman; Litonjua, Augusto A; Mueller, Geoffrey A; O'Connor, George T; Ownby, Dennis; Phipatanakul, Wanda; Persky, Victoria; Perzanowski, Matthew S; Ramsey, Clare D; Salo, Päivi M; Schwaninger, Julie M; Sordillo, Joanne E; Spira, Avrum; Suglia, Shakira F; Togias, Alkis; Zeldin, Darryl C; Matsui, Elizabeth C

    2017-10-01

    Environmental exposures have been recognized as critical in the initiation and exacerbation of asthma, one of the most common chronic childhood diseases. The National Institute of Allergy and Infectious Diseases; National Institute of Environmental Health Sciences; National Heart, Lung, and Blood Institute; and Merck Childhood Asthma Network sponsored a joint workshop to discuss the current state of science with respect to the indoor environment and its effects on the development and morbidity of childhood asthma. The workshop included US and international experts with backgrounds in allergy/allergens, immunology, asthma, environmental health, environmental exposures and pollutants, epidemiology, public health, and bioinformatics. Workshop participants provided new insights into the biologic properties of indoor exposures, indoor exposure assessment, and exposure reduction techniques. This informed a primary focus of the workshop: to critically review trials and research relevant to the prevention or control of asthma through environmental intervention. The participants identified important limitations and gaps in scientific methodologies and knowledge and proposed and prioritized areas for future research. The group reviewed socioeconomic and structural challenges to changing environmental exposure and offered recommendations for creative study design to overcome these challenges in trials to improve asthma management. The recommendations of this workshop can serve as guidance for future research in the study of the indoor environment and on environmental interventions as they pertain to the prevention and management of asthma and airway allergies. Published by Elsevier Inc.

  11. A Fast and Precise Indoor Localization Algorithm Based on an Online Sequential Extreme Learning Machine †

    PubMed Central

    Zou, Han; Lu, Xiaoxuan; Jiang, Hao; Xie, Lihua

    2015-01-01

    Nowadays, developing indoor positioning systems (IPSs) has become an attractive research topic due to the increasing demands on location-based service (LBS) in indoor environments. WiFi technology has been studied and explored to provide indoor positioning service for years in view of the wide deployment and availability of existing WiFi infrastructures in indoor environments. A large body of WiFi-based IPSs adopt fingerprinting approaches for localization. However, these IPSs suffer from two major problems: the intensive costs of manpower and time for offline site survey and the inflexibility to environmental dynamics. In this paper, we propose an indoor localization algorithm based on an online sequential extreme learning machine (OS-ELM) to address the above problems accordingly. The fast learning speed of OS-ELM can reduce the time and manpower costs for the offline site survey. Meanwhile, its online sequential learning ability enables the proposed localization algorithm to adapt in a timely manner to environmental dynamics. Experiments under specific environmental changes, such as variations of occupancy distribution and events of opening or closing of doors, are conducted to evaluate the performance of OS-ELM. The simulation and experimental results show that the proposed localization algorithm can provide higher localization accuracy than traditional approaches, due to its fast adaptation to various environmental dynamics. PMID:25599427

  12. Design and application of an inertial impactor in combination with an ATP bioluminescence detector for in situ rapid estimation of the efficacies of air controlling devices on removal of bioaerosols.

    PubMed

    Yoon, Ki Young; Park, Chul Woo; Byeon, Jeong Hoon; Hwang, Jungho

    2010-03-01

    We proposed a rapid method to estimate the efficacies of air controlling devices in situ using ATP bioluminescence in combination with an inertial impactor. The inertial impactor was designed to have 1 mum of cutoff diameter, and its performance was estimated analytically, numerically, and experimentally. The proposed method was characterized using Staphylococcus epidermidis, which was aerosolized with a nebulizer. The bioaerosol concentrations were estimated within 25 min using the proposed method without a culturing process, which requires several days for colony formation. A linear relationship was obtained between the results of the proposed ATP method (RLU/m(3)) and the conventional culture-based method (CFU/m(3)), with R(2) 0.9283. The proposed method was applied to estimate the concentration of indoor bioaerosols, which were identified as a mixture of various microbial species including bacteria, fungi, and actinomycetes, in an occupational indoor environment, controlled by mechanical ventilation and an air cleaner. Consequently, the proposed method showed a linearity with the culture-based method for indoor bioaerosols with R(2) 0.8189, even though various kinds of microorganisms existed in the indoor air. The proposed method may be effective in monitoring the changes of relative concentration of indoor bioaerosols and estimating the effectiveness of air control devices in indoor environments.

  13. Adaptive Indoor Positioning Model Based on WLAN-Fingerprinting for Dynamic and Multi-Floor Environments

    PubMed Central

    Alshami, Iyad Husni; Sahibuddin, Shamsul; Firdaus, Firdaus

    2017-01-01

    The Global Positioning System demonstrates the significance of Location Based Services but it cannot be used indoors due to the lack of line of sight between satellites and receivers. Indoor Positioning Systems are needed to provide indoor Location Based Services. Wireless LAN fingerprints are one of the best choices for Indoor Positioning Systems because of their low cost, and high accuracy, however they have many drawbacks: creating radio maps is time consuming, the radio maps will become outdated with any environmental change, different mobile devices read the received signal strength (RSS) differently, and peoples’ presence in LOS between access points and mobile device affects the RSS. This research proposes a new Adaptive Indoor Positioning System model (called DIPS) based on: a dynamic radio map generator, RSS certainty technique and peoples’ presence effect integration for dynamic and multi-floor environments. Dynamic in our context refers to the effects of people and device heterogeneity. DIPS can achieve 98% and 92% positioning accuracy for floor and room positioning, and it achieves 1.2 m for point positioning error. RSS certainty enhanced the positioning accuracy for floor and room for different mobile devices by 11% and 9%. Then by considering the peoples’ presence effect, the error is reduced by 0.2 m. In comparison with other works, DIPS achieves better positioning without extra devices. PMID:28783047

  14. Employing ASHRAE Standard 62-1989 in urban building environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meckler, M.

    1991-01-01

    Indoor air quality (IAQ) is a result of a complex relationship between the contamination sources in a building, the ventilation rate, and the dilution of the indoor air contaminant concentrations with outdoor air. This complex relationship is further complicated by outdoor sources used for dilution air and pollution sinks in a building which may modify or remove contaminants. This paper reports that the factors influencing IAQ in a building are: emissions from indoor contamination sources, dilution rate of outdoor ventilation air, quality of the outdoor dilution air, and systems and materials in a building that change the concentrations of contaminants.more » Emissions from contaminant sources in a building are the primary determinant of IAQ. They include building materials, consumer products, cleaners, furnishings, combustion appliances and processes, biological growth from standing water and damp surfaces and building occupants. These factors combined with the emissions from indoor air contamination sources such as synthetic building materials, modern office equipment, and cleaning and biological agents are believed to increase the levels of indoor air contamination. The physiological reactions to these contaminants, coupled with the psychosocial stresses of the modern office environment, and the wide range of human susceptibility to indoor air contaminants led to the classification of acute building sicknesses: sick building syndrome (SBS), building-related illness (BRI), and multiple chemical sensitivity (MCS).« less

  15. Effects of moisture controlled charcoal on indoor thermal and air environments

    NASA Astrophysics Data System (ADS)

    Matsumoto, Hiroshi; Yokogoshi, Midori; Nabeshima, Yuki

    2017-10-01

    It is crucial to remove and control indoor moisture in Japan, especially in hot and humid summers, in order to improve thermal comfort and save energy in buildings. Charcoal for moisture control made from the waste of wood material has attracted attention among many control strategies to control indoor moisture, and it is beginning to be used in houses. However, the basic characteristics of the charcoal to control moisture and remove chemical compounds in indoor air have not been investigated sufficiently. The objective of this study is to clarify the effect of moisture control charcoal on indoor thermal and air environments by a long-term field measurement using two housing scale models with/without charcoal in Toyohashi, Japan. The comparative experiments to investigate the effect of the charcoal on air temperature and humidity for two models with/without charcoal were conducted from 2015 to 2016. Also, the removal performance of volatile organic compound (VOCs) was investigated in the summer of 2015. Four bags of packed charcoal were set on the floor in the attic for one model during the experiment. As a result of the experiments, a significant effect of moisture control was observed in hot and humid season, and the efficient effect of moisture adsorption was obtained by the periodic humidification experiment using a humidifier. Furthermore, the charcoal showed a remarkable performance of VOC removal from indoor air by the injection experiment of formaldehyde.

  16. Climate change and health: Indoor heat exposure in vulnerable populations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White-Newsome, Jalonne L., E-mail: jalonne@umich.edu; Sanchez, Brisa N., E-mail: brisa@umich.edu; Jolliet, Olivier, E-mail: ojolliet@umich.edu

    2012-01-15

    Introduction: Climate change is increasing the frequency of heat waves and hot weather in many urban environments. Older people are more vulnerable to heat exposure but spend most of their time indoors. Few published studies have addressed indoor heat exposure in residences occupied by an elderly population. The purpose of this study is to explore the relationship between outdoor and indoor temperatures in homes occupied by the elderly and determine other predictors of indoor temperature. Materials and methods: We collected hourly indoor temperature measurements of 30 different homes; outdoor temperature, dewpoint temperature, and solar radiation data during summer 2009 inmore » Detroit, MI. We used mixed linear regression to model indoor temperatures' responsiveness to weather, housing and environmental characteristics, and evaluated our ability to predict indoor heat exposures based on outdoor conditions. Results: Average maximum indoor temperature for all locations was 34.85 Degree-Sign C, 13.8 Degree-Sign C higher than average maximum outdoor temperature. Indoor temperatures of single family homes constructed of vinyl paneling or wood siding were more sensitive than brick homes to outdoor temperature changes and internal heat gains. Outdoor temperature, solar radiation, and dewpoint temperature predicted 38% of the variability of indoor temperatures. Conclusions: Indoor exposures to heat in Detroit exceed the comfort range among elderly occupants, and can be predicted using outdoor temperatures, characteristics of the housing stock and surroundings to improve heat exposure assessment for epidemiological investigations. Weatherizing homes and modifying home surroundings could mitigate indoor heat exposure among the elderly.« less

  17. Analysis of isocyanates in indoor dust.

    PubMed

    Bekki, Kanae; Uchiyama, Shigehisa; Kunugita, Naoki

    2018-05-04

    Isocyanates are harmful semi-volatile organic compounds that are emitted from various consumer products like polyurethane foam-based mattresses. Although it is a concern that isocyanates might accumulate in indoor dust, causing infants and toddlers, in particular, to be exposed to them, little information is available on the levels of isocyanates in the indoor environment. In this study, we investigated the suitability of an analytical method for determining the presence and level of isocyanates in the indoor dust. The method we developed displayed acceptable linearity, accuracy, and precision in the analysis of eleven different isocyanates. By using this analytical method, we could detect five isocyanates (ICA, MIC, EIC, PIC, and PHI) and quantify three isocyanates (MIC, EIC, and PHI) in indoor dust collected in different houses. This study is the first to focus on the pollution of indoor dust by isocyanates, and the tested method is suitable for the estimation of the level of isocyanate exposure. Graphical abstract ᅟ.

  18. Psychotropic substances in indoor environments.

    PubMed

    Cecinato, Angelo; Romagnoli, Paola; Perilli, Mattia; Patriarca, Claudia; Balducci, Catia

    2014-10-01

    The presence of drugs in outdoor air has been established, but few investigations have been conducted indoors. This study focused on psychotropic substances (PSs) at three schools, four homes and one office in Rome, Italy. The indoor drug concentrations and the relationships with the outdoor atmosphere were investigated. The optimised monitoring procedure allowed for the determination of cocaine, cannabinoids and particulate fractions of nicotine and caffeine. In-field experiments were performed during the winter, spring and summer seasons. Psychotropic substances were observed in all indoor locations. The indoor concentrations often exceeded those recorded both outdoors at the same sites and at the atmospheric pollution control network stations, indicating that the drugs were released into the air at the inside sites or were more persistent. During winter, the relative concentrations of cannabinol, cannabidiol and tetrahydrocannabinol depended on site and indoor/outdoor location at the site. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Psychosocial dimensions of solving an indoor air problem.

    PubMed

    Lahtinen, Marjaana; Huuhtanen, Pekka; Kähkönen, Erkki; Reijula, Kari

    2002-03-01

    This investigation focuses on the psychological and social dimensions of managing and solving indoor air problems. The data were collected in nine workplaces by interviews (n = 85) and questionnaires (n = 375). Indoor air problems in office environments have traditionally utilized industrial hygiene or technical expertise. However, indoor air problems at workplaces are often more complex issues to solve. Technical questions are inter-related with the dynamics of the work community, and the cooperation and interaction skills of the parties involved in the solving process are also put to the test. In the present study, the interviewees were very critical of the process of solving the indoor air problem. The responsibility for coordinating the problem-managing process was generally considered vague, as were the roles and functions of the various parties. Communication problems occurred and rumors about the indoor air problem circulated widely. Conflicts were common, complicating the process in several ways. The research focused on examining different ways of managing and resolving an indoor air problem. In addition, reference material on the causal factors of the indoor air problem was also acquired. The study supported the hypothesis that psychosocial factors play a significant role in indoor air problems.

  20. Summer indoor heat exposure and respiratory and cardiovascular distress calls in New York City, NY, U.S

    PubMed Central

    Uejio, C. K.; Tamerius, J. D.; Vredenburg, J.; Asaeda, G.; Isaacs, D. A.; Braun, J.; Quinn, A.; Freese, J. P.

    2016-01-01

    Most extreme heat studies relate outdoor weather conditions to human morbidity and mortality. In developed nations, individuals spend ~90% of their time indoors. This pilot study investigated the indoor environments of people receiving emergency medical care in New York City, NY, U.S., from July to August 2013. The first objective was to determine the relative influence of outdoor conditions as well as patient characteristics and neighborhood sociodemographics on indoor temperature and specific humidity (N = 764). The second objective was to determine whether cardiovascular or respiratory cases experience hotter and more humid indoor conditions as compared to controls. Paramedics carried portable sensors into buildings where patients received care to passively monitor indoor temperature and humidity. The case–control study compared 338 respiratory cases, 291 cardiovascular cases, and 471 controls. Intuitively, warmer and sunnier outdoor conditions increased indoor temperatures. Older patients who received emergency care tended to occupy warmer buildings. Indoor-specific humidity levels quickly adjusted to outdoor conditions. Indoor heat and humidity exposure above a 26 °C threshold increased (OR: 1.63, 95% CI: 0.98–2.68, P = 0.056), but not significantly, the proportion of respiratory cases. Indoor heat exposures were similar between cardiovascular cases and controls. PMID:26086869

  1. Mobile indoor localization using Kalman filter and trilateration technique

    NASA Astrophysics Data System (ADS)

    Wahid, Abdul; Kim, Su Mi; Choi, Jaeho

    2015-12-01

    In this paper, an indoor localization method based on Kalman filtered RSSI is presented. The indoor communications environment however is rather harsh to the mobiles since there is a substantial number of objects distorting the RSSI signals; fading and interference are main sources of the distortion. In this paper, a Kalman filter is adopted to filter the RSSI signals and the trilateration method is applied to obtain the robust and accurate coordinates of the mobile station. From the indoor experiments using the WiFi stations, we have found that the proposed algorithm can provide a higher accuracy with relatively lower power consumption in comparison to a conventional method.

  2. Extracting Topological Relations Between Indoor Spaces from Point Clouds

    NASA Astrophysics Data System (ADS)

    Tran, H.; Khoshelham, K.; Kealy, A.; Díaz-Vilariño, L.

    2017-09-01

    3D models of indoor environments are essential for many application domains such as navigation guidance, emergency management and a range of indoor location-based services. The principal components defined in different BIM standards contain not only building elements, such as floors, walls and doors, but also navigable spaces and their topological relations, which are essential for path planning and navigation. We present an approach to automatically reconstruct topological relations between navigable spaces from point clouds. Three types of topological relations, namely containment, adjacency and connectivity of the spaces are modelled. The results of initial experiments demonstrate the potential of the method in supporting indoor navigation.

  3. US EPA Base Study Standard Operating Procedure for Sampling Volatile Organic Compounds in Indoor Air using Multisorbent Samplers

    EPA Pesticide Factsheets

    The objective of this procedure is to collect representative samples of volatile organic compound (VOC) contaminants present in indoor and outdoor environments using multisorbent samplers, and to subsequently analyze the concentration of VOCs, as selected by EPA.

  4. Long-term integrating samplers for indoor air and sub slab soil gas at VI sites

    EPA Science Inventory

    Vapor intrusion (VI) site assessments are plagued by substantial spatial and temporal variability that makes exposure and risk assessment difficult. Most risk-based decision making for volatile organic compound (VOC) exposure in the indoor environment is based on health benchmark...

  5. Association of Stremptomyces community composition determined by PCR-denaturing gradient gel electrophoresis with indoor mold status.

    EPA Science Inventory

    Abstract Both Streptomyces species and mold species have previously been isolated from moisture-damaged building materials; however, an association between these two groups of microorganisms in indoor environments is not clear. In this study, we used a cultureindependent met...

  6. Extraction of Aerosol-Deposited Yersinia pestis from Indoor Surfaces To Determine Bacterial Environmental Decay.

    PubMed

    Gut, Ian M; Bartlett, Ryan A; Yeager, John J; Leroux, Brian; Ratnesar-Shumate, Shanna; Dabisch, Paul; Karaolis, David K R

    2016-05-01

    Public health and decontamination decisions following an event that causes indoor contamination with a biological agent require knowledge of the environmental persistence of the agent. The goals of this study were to develop methods for experimentally depositing bacteria onto indoor surfaces via aerosol, evaluate methods for sampling and enumerating the agent on surfaces, and use these methods to determine bacterial surface decay. A specialized aerosol deposition chamber was constructed, and methods were established for reproducible and uniform aerosol deposition of bacteria onto four coupon types. The deposition chamber facilitated the control of relative humidity (RH; 10 to 70%) following particle deposition to mimic the conditions of indoor environments, as RH is not controlled by standard heating, ventilation, and air conditioning (HVAC) systems. Extraction and culture-based enumeration methods to quantify the viable bacteria on coupons were shown to be highly sensitive and reproducible. To demonstrate the usefulness of the system for decay studies,Yersinia pestis persistence as a function of surface type at 21 °C and 40% RH was determined to be >40%/min for all surfaces. Based upon these results, at typical indoor temperature and RH, a 6-log reduction in titer would expected to be achieved within 1 h as the result of environmental decay on surfaces without active decontamination. The developed approach will facilitate future persistence and decontamination studies with a broad range of biological agents and surfaces, providing agent decay data to inform both assessments of risk to personnel entering a contaminated site and decontamination decisions following biological contamination of an indoor environment. Public health and decontamination decisions following contamination of an indoor environment with a biological agent require knowledge of the environmental persistence of the agent. Previous studies on Y. pestis persistence have utilized large liquid droplet deposition to provide persistence data. As a result, methods were developed to deposit aerosols containing bacteria onto indoor surfaces, reproducibly enumerate bacteria harvested from coupons, and determine surface decay utilizing Y. pestis The results of this study provide foundational methods required to evaluate surface decay of bacteria and potentially other biological agents, such as viruses, in aerosol particles as a function of surface type and environment. Integrating the data from both aerosol and liquid deposition surface decay studies will provide medical and public health personnel with a more complete understanding of agent persistence on surfaces in contaminated areas for assessment of health risks and to inform decontamination decisions. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  7. Extraction of Aerosol-Deposited Yersinia pestis from Indoor Surfaces To Determine Bacterial Environmental Decay

    PubMed Central

    Bartlett, Ryan A.; Yeager, John J.; Leroux, Brian; Ratnesar-Shumate, Shanna; Dabisch, Paul

    2016-01-01

    ABSTRACT Public health and decontamination decisions following an event that causes indoor contamination with a biological agent require knowledge of the environmental persistence of the agent. The goals of this study were to develop methods for experimentally depositing bacteria onto indoor surfaces via aerosol, evaluate methods for sampling and enumerating the agent on surfaces, and use these methods to determine bacterial surface decay. A specialized aerosol deposition chamber was constructed, and methods were established for reproducible and uniform aerosol deposition of bacteria onto four coupon types. The deposition chamber facilitated the control of relative humidity (RH; 10 to 70%) following particle deposition to mimic the conditions of indoor environments, as RH is not controlled by standard heating, ventilation, and air conditioning (HVAC) systems. Extraction and culture-based enumeration methods to quantify the viable bacteria on coupons were shown to be highly sensitive and reproducible. To demonstrate the usefulness of the system for decay studies, Yersinia pestis persistence as a function of surface type at 21°C and 40% RH was determined to be >40%/min for all surfaces. Based upon these results, at typical indoor temperature and RH, a 6-log reduction in titer would expected to be achieved within 1 h as the result of environmental decay on surfaces without active decontamination. The developed approach will facilitate future persistence and decontamination studies with a broad range of biological agents and surfaces, providing agent decay data to inform both assessments of risk to personnel entering a contaminated site and decontamination decisions following biological contamination of an indoor environment. IMPORTANCE Public health and decontamination decisions following contamination of an indoor environment with a biological agent require knowledge of the environmental persistence of the agent. Previous studies on Y. pestis persistence have utilized large liquid droplet deposition to provide persistence data. As a result, methods were developed to deposit aerosols containing bacteria onto indoor surfaces, reproducibly enumerate bacteria harvested from coupons, and determine surface decay utilizing Y. pestis. The results of this study provide foundational methods required to evaluate surface decay of bacteria and potentially other biological agents, such as viruses, in aerosol particles as a function of surface type and environment. Integrating the data from both aerosol and liquid deposition surface decay studies will provide medical and public health personnel with a more complete understanding of agent persistence on surfaces in contaminated areas for assessment of health risks and to inform decontamination decisions. PMID:26944839

  8. Ubiquitous Indoor Geolocation: a Case Study of Jewellery Management System

    NASA Astrophysics Data System (ADS)

    Nikparvar, B.; Sadeghi-Niaraki, A.; Azari, P.

    2014-10-01

    Addressing and geolocation for indoor environments are important fields of research in the recent years. The problem of finding location of objects in indoor spaces is proposed to solve in two ways. The first, is to assign coordinates to objects and second is to divide space into cells and detect the presence or absence of objects in each cell to track them. In this paper the second approach is discussed by using Radio Frequency Identification technology to identify and track high value objects in jewellery retail industry. In Ubiquitous Sensor Networks, the reactivity or proactivity of the environment are important issues. Reactive environments wait for a request to response to it. Instead, in proactive spaces, the environment acts in advance to deal with an expected action. In this research, a geo-sensor network containing RFID readers, tags, and antennas which continuously exchange radio frequency signal streams is proposed to manage and monitor jewellery galleries ubiquitously. The system is also equipped with a GIS representation which provides a more user-friendly system to manage a jewellery gallery.

  9. Indoor space 3D visual reconstruction using mobile cart with laser scanner and cameras

    NASA Astrophysics Data System (ADS)

    Gashongore, Prince Dukundane; Kawasue, Kikuhito; Yoshida, Kumiko; Aoki, Ryota

    2017-02-01

    Indoor space 3D visual reconstruction has many applications and, once done accurately, it enables people to conduct different indoor activities in an efficient manner. For example, an effective and efficient emergency rescue response can be accomplished in a fire disaster situation by using 3D visual information of a destroyed building. Therefore, an accurate Indoor Space 3D visual reconstruction system which can be operated in any given environment without GPS has been developed using a Human-Operated mobile cart equipped with a laser scanner, CCD camera, omnidirectional camera and a computer. By using the system, accurate indoor 3D Visual Data is reconstructed automatically. The obtained 3D data can be used for rescue operations, guiding blind or partially sighted persons and so forth.

  10. Predictors of indoor absolute humidity and estimated effects on influenza virus survival in grade schools

    PubMed Central

    2013-01-01

    Background Low absolute humidity (AH) has been associated with increased influenza virus survival and transmissibility and the onset of seasonal influenza outbreaks. Humidification of indoor environments may mitigate viral transmission and may be an important control strategy, particularly in schools where viral transmission is common and contributes to the spread of influenza in communities. However, the variability and predictors of AH in the indoor school environment and the feasibility of classroom humidification to levels that could decrease viral survival have not been studied. Methods Automated sensors were used to measure temperature, humidity and CO2 levels in two Minnesota grade schools without central humidification during two successive winters. Outdoor AH measurements were derived from the North American Land Data Assimilation System. Variability in indoor AH within classrooms, between classrooms in the same school, and between schools was assessed using concordance correlation coefficients (CCC). Predictors of indoor AH were examined using time-series Auto-Regressive Conditional Heteroskedasticity models. Classroom humidifiers were used when school was not in session to assess the feasibility of increasing indoor AH to levels associated with decreased influenza virus survival, as projected from previously published animal experiments. Results AH varied little within classrooms (CCC >0.90) but was more variable between classrooms in the same school (CCC 0.81 for School 1, 0.88 for School 2) and between schools (CCC 0.81). Indoor AH varied widely during the winter (range 2.60 to 10.34 millibars [mb]) and was strongly associated with changes in outdoor AH (p < 0.001). Changes in indoor AH on school weekdays were strongly associated with CO2 levels (p < 0.001). Over 4 hours, classroom humidifiers increased indoor AH by 4 mb, an increase sufficient to decrease projected 1-hour virus survival by an absolute value of 30% during winter months. Conclusions During winter, indoor AH in non-humidified grade schools varies substantially and often to levels that are very low. Indoor results are predicted by outdoor AH over a season and CO2 levels (which likely reflects human activity) during individual school days. Classroom humidification may be a feasible approach to increase indoor AH to levels that may decrease influenza virus survival and transmission. PMID:23383620

  11. Scene analysis for a breadboard Mars robot functioning in an indoor environment

    NASA Technical Reports Server (NTRS)

    Levine, M. D.

    1973-01-01

    The problem is delt with of computer perception in an indoor laboratory environment containing rocks of various sizes. The sensory data processing is required for the NASA/JPL breadboard mobile robot that is a test system for an adaptive variably-autonomous vehicle that will conduct scientific explorations on the surface of Mars. Scene analysis is discussed in terms of object segmentation followed by feature extraction, which results in a representation of the scene in the robot's world model.

  12. The Uranus Mobile Robot

    DTIC Science & Technology

    1990-09-01

    maneuver in a cluttered indoor environment . Since Pluto could position itself in any orientation, it would also allow us to mount a robot arm on top of...reasons. First, it gives the payload a smoother ride: although the robot operates in an indoor environment , there are still cables and door thresholds to...form a self-holding circuit. A small DPDT relay powers the proper indicator light and is also 9 Batery en main Inlet O60A 24VDC Off Board On Board(NO

  13. Indoor mold spore exposure: characteristics of 127 homes in southern California with endogenous mold problems.

    PubMed

    Gallup, J; Kozak, P; Cummins, L; Gillman, S

    1987-01-01

    We are constantly being exposed to molds in our environment. Indoor mold problems occur after prolonged or chronic water damage to a variety of organic materials such as unfinished wood, jutebacked carpeting, wallpaper, books, cardboard, leather, cork, paper, wallboard, and wicker baskets. Mechanisms for spore dispersal (such as air currents or foot traffic on carpets) must also be present. The presence of these organic materials and dispersal mechanisms leads to significant increases in indoor spore levels.

  14. Development of an indoor location based service test bed and geographic information system with a wireless sensor network.

    PubMed

    Jan, Shau-Shiun; Hsu, Li-Ta; Tsai, Wen-Ming

    2010-01-01

    In order to provide the seamless navigation and positioning services for indoor environments, an indoor location based service (LBS) test bed is developed to integrate the indoor positioning system and the indoor three-dimensional (3D) geographic information system (GIS). A wireless sensor network (WSN) is used in the developed indoor positioning system. Considering the power consumption, in this paper the ZigBee radio is used as the wireless protocol, and the received signal strength (RSS) fingerprinting positioning method is applied as the primary indoor positioning algorithm. The matching processes of the user location include the nearest neighbor (NN) algorithm, the K-weighted nearest neighbors (KWNN) algorithm, and the probabilistic approach. To enhance the positioning accuracy for the dynamic user, the particle filter is used to improve the positioning performance. As part of this research, a 3D indoor GIS is developed to be used with the indoor positioning system. This involved using the computer-aided design (CAD) software and the virtual reality markup language (VRML) to implement a prototype indoor LBS test bed. Thus, a rapid and practical procedure for constructing a 3D indoor GIS is proposed, and this GIS is easy to update and maintenance for users. The building of the Department of Aeronautics and Astronautics at National Cheng Kung University in Taiwan is used as an example to assess the performance of various algorithms for the indoor positioning system.

  15. Development of an Indoor Location Based Service Test Bed and Geographic Information System with a Wireless Sensor Network

    PubMed Central

    Jan, Shau-Shiun; Hsu, Li-Ta; Tsai, Wen-Ming

    2010-01-01

    In order to provide the seamless navigation and positioning services for indoor environments, an indoor location based service (LBS) test bed is developed to integrate the indoor positioning system and the indoor three-dimensional (3D) geographic information system (GIS). A wireless sensor network (WSN) is used in the developed indoor positioning system. Considering the power consumption, in this paper the ZigBee radio is used as the wireless protocol, and the received signal strength (RSS) fingerprinting positioning method is applied as the primary indoor positioning algorithm. The matching processes of the user location include the nearest neighbor (NN) algorithm, the K-weighted nearest neighbors (KWNN) algorithm, and the probabilistic approach. To enhance the positioning accuracy for the dynamic user, the particle filter is used to improve the positioning performance. As part of this research, a 3D indoor GIS is developed to be used with the indoor positioning system. This involved using the computer-aided design (CAD) software and the virtual reality markup language (VRML) to implement a prototype indoor LBS test bed. Thus, a rapid and practical procedure for constructing a 3D indoor GIS is proposed, and this GIS is easy to update and maintenance for users. The building of the Department of Aeronautics and Astronautics at National Cheng Kung University in Taiwan is used as an example to assess the performance of various algorithms for the indoor positioning system. PMID:22319282

  16. US EPA Base Study Standard Operating Procedure for Continuous Monitoring of Indoor Air

    EPA Pesticide Factsheets

    The procedure described is intended for monitoring continuously and simultaneously, at selected work sites, parameters that are most commonly associated with the quality of indoor environments: the concentrations of carbon dioxide (CO2), carbon monoxide (CO), temperature, relative humidity (RH), illumination, and noise.

  17. CONCENTRATIONS OF PARTICULATE ORGANIC SPECIES MEASURED IN INDOOR AND OUTDOOR ENVIRONMENTS DURING THE TAMPA ASTHMATIC CHILDREN'S STUDY ( TACS )

    EPA Science Inventory

    The Tampa Asthmatic Children's Study (TACS) was completed to assess environmental exposures for a group of asthmatic children (n = 9) under the age of six and living in Tampa, Florida. Concentrations of particulate organic species are reported from residential indoor, residential...

  18. Therapeutic Play at Inflatable Playgrounds

    ERIC Educational Resources Information Center

    Yavorcik, Carin

    2009-01-01

    The environment at indoor inflatable playgrounds, featuring giant bounce houses and slides, can become an ideal place for children with autism to receive helpful sensations. This is the reasoning behind Sensory Nights hosted by the Autism Society of America and Pump It Up, a national franchise of giant, indoor inflatable playgrounds. The private…

  19. DISSOCIATION OF SULFUR HEXAFLUORIDE TRACER GAS IN THE PRESENCE OF AN INDOOR COMBUSTION SOURCE

    EPA Science Inventory

    As an odorless, non-toxic, and inert compound, sulfur hexafluoride (SF6) is one of the most widely used tracer gases in indoor air quality studies in both controlled and uncontrolled environments. This compound may be subject to hydrolysis under elevated temperature to form acidi...

  20. SOURCES AND FACTORS AFFECTING INDOOR EMISSIONS FROM ENGINEERED WOOD PRODUCTS: SUMMARY AND EVALUATION OF CURRENT LITERATURE

    EPA Science Inventory

    The report summarizes information from the first two phases of a five-phase cooperative effort between research Triangle Institute and the Indoor Environment Management Branch of the U.S. Environmental Protection Agency's Air Pollution Prevention and Control Division to apply pol...

  1. US EPA Base Study Standard Operating Procedure for Sampling Volatile Organic Compounds in Indoor Air Using Evacuated Canisters

    EPA Pesticide Factsheets

    The objective of this procedure is to collect a representative sample of air containing volatile organic compound (VOC) contaminants present in an indoor environment using an evacuated canister, and to subsequently analyze the concentration of VOCs, as selected by EPA.

  2. Indoor air quality of houses located in the urban environment of Agra, India.

    PubMed

    Taneja, Ajay; Saini, Renuka; Masih, Amit

    2008-10-01

    Increased concern over the adverse health effects of air pollution has highlighted the need for air-pollution measurements, especially in urban areas, where many sources of air pollutants are normally monitored outdoors as part of obligations under the National Air Quality Strategies. Very little is known about air pollution indoors. In fact, the largest exposure to health-damaging indoor pollution probably occurs in the developing world, not in households, schools, and offices of developed countries where most research and control efforts have been focused to date. As a result much of the health impacts from air pollution worldwide seem to occur among the poorest and most vulnerable populations. The authors in their earlier studies have confirmed the importance of ambient air in determining the quality of air indoors. In this study an observation of air quality indoors and outdoors of domestic homes located in an urban environment from October 2004 to December 2005 in Agra, north central India, is performed. The purpose of this study was to characterize the indoor/outdoor (I/O) relationship of airborne pollutants and recognize their probable source in all three seasons, that is, winter, summer, and rainy season. Concentrations of SO(2), NO(2), CO(2), Cl(2), H(2)S, NH(3), RSPM, and PAH were monitored simultaneously and I/O ratios were calculated. In order to investigate the effect of seasonality on indoor and ambient air quality, winter to summer and winter to monsoon average ratios were calculated. It is apparent that there is a general pattern of increasing levels from monsoon to summer to winter, and similarly from outdoor to indoor air. Regressions analysis had been done to further investigate the influence of outdoor air-pollutant concentrations on indoor concentrations. The most probable categories of sources for these pollutants have been identified by using principal-component analysis. Indoor air pollution is a complex function of energy housing and behavioral factors. On the basis of this study and observations, some interventions are also suggested.

  3. School Environmental Intervention Programs.

    PubMed

    Permaul, Perdita; Phipatanakul, Wanda

    Exposure to indoor allergens and pollutants plays a significant part in the development of asthma and its associated morbidity. Inner-city children with asthma are disproportionately affected by these exposures with increased asthma morbidity. Although years of previous research have linked exposures in the urban home environment with significant childhood asthma disease, many of these allergens are also present in inner-city school environments. Therefore, evaluation of the school environment of patients with asthma is also essential. School-based environmental interventions may offer benefit for this problem and has the potential to help many children with asthma at once in a cost-effective manner. It is important that environmental health researchers continue to assess which interventions are most practical and result in the greatest measurable improvements. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  4. Walls talk: Microbial biogeography of homes spanning urbanization

    PubMed Central

    Ruiz-Calderon, Jean F.; Cavallin, Humberto; Song, Se Jin; Novoselac, Atila; Pericchi, Luis R.; Hernandez, Jean N.; Rios, Rafael; Branch, Oralee H.; Pereira, Henrique; Paulino, Luciana C.; Blaser, Martin J.; Knight, Rob; Dominguez-Bello, Maria G.

    2016-01-01

    Westernization has propelled changes in urbanization and architecture, altering our exposure to the outdoor environment from that experienced during most of human evolution. These changes might affect the developmental exposure of infants to bacteria, immune development, and human microbiome diversity. Contemporary urban humans spend most of their time indoors, and little is known about the microbes associated with different designs of the built environment and their interaction with the human immune system. This study addresses the associations between architectural design and the microbial biogeography of households across a gradient of urbanization in South America. Urbanization was associated with households’ increased isolation from outdoor environments, with additional indoor space isolation by walls. Microbes from house walls and floors segregate by location, and urban indoor walls contain human bacterial markers of space use. Urbanized spaces uniquely increase the content of human-associated microbes—which could increase transmission of potential pathogens—and decrease exposure to the environmental microbes with which humans have coevolved. PMID:26933683

  5. Real-time localization of mobile device by filtering method for sensor fusion

    NASA Astrophysics Data System (ADS)

    Fuse, Takashi; Nagara, Keita

    2017-06-01

    Most of the applications with mobile devices require self-localization of the devices. GPS cannot be used in indoor environment, the positions of mobile devices are estimated autonomously by using IMU. Since the self-localization is based on IMU of low accuracy, and then the self-localization in indoor environment is still challenging. The selflocalization method using images have been developed, and the accuracy of the method is increasing. This paper develops the self-localization method without GPS in indoor environment by integrating sensors, such as IMU and cameras, on mobile devices simultaneously. The proposed method consists of observations, forecasting and filtering. The position and velocity of the mobile device are defined as a state vector. In the self-localization, observations correspond to observation data from IMU and camera (observation vector), forecasting to mobile device moving model (system model) and filtering to tracking method by inertial surveying and coplanarity condition and inverse depth model (observation model). Positions of a mobile device being tracked are estimated by system model (forecasting step), which are assumed as linearly moving model. Then estimated positions are optimized referring to the new observation data based on likelihood (filtering step). The optimization at filtering step corresponds to estimation of the maximum a posterior probability. Particle filter are utilized for the calculation through forecasting and filtering steps. The proposed method is applied to data acquired by mobile devices in indoor environment. Through the experiments, the high performance of the method is confirmed.

  6. Correlation between Novel Potential Indoor Risk Factors and Frequency of Doctor's Visit for Respiratory Problem in Taiwan's Tropical Environment.

    PubMed

    Wang, Yu-Hao; Su, Hsing-Hao; Hsu, Lan; Wang, Chung-Yang; Wu, Pi-Hsiung

    2018-01-01

    With a global rising trend in prevalence of allergic diseases, more attention has been paid to investigation of environmental risk factors. Many risk factors have so far been identified. However, novel risk factors specific to Taiwanese environment and lifestyle were still relatively unknown. To investigate the potential effects of a number of little-known indoor risk factors on the frequency of doctor's visit for respiratory problems in context of Taiwanese environment and lifestyle. A cross-sectional, population-based study was performed on a 861 participants around Kaohsiung area, Taiwan. Survey investigation was employed to assess the household environment and the frequency of doctor's visit for respiratory problems. Participants who performed "daily cleaning" was shown to have a significantly (p=0.007) higher mean number of doctor's visits in comparison to those who did not. Similar observation was made for participants who periodically took out beddings (p=0.042). Age had a significant positive correlation (linear regression β 0.089) with frequency of respiratory problems. The habit of daily cleaning was implicated as a potential indoor risk factor due to the unique nature of Taiwanese cleaning habit and close contact with cleaning supplies, which could serve as chemical irritants. Bedding takeout was predicted to be an indicator of chronic allergies rather than an actual risk factor. However, both were controversial in their role as potential indoor risk factor, and required further examination.

  7. Children's exposure to brominated flame retardants in indoor environments - A review.

    PubMed

    Malliari, Eleftheria; Kalantzi, Olga-Ioanna

    2017-11-01

    The aim of this review is to present up-to-date research on children's exposure to brominated flame retardants (BFRs) in indoor environments. Large geographical variations were observed for all BFRs [polybrominated diphenyl ethers (PBDEs), hexabromocyclododecane (HBCDD), tetrabromobisphenol A (TBBPA)], with the highest concentrations of PBDEs measured in North America (BDE-47) and Europe (BDE-209), where higher concentrations of PBDEs are present in dust from houses, daycare centers and primary schools. In Asia the highest PBDE concentrations were measured in China, near e-waste recycling areas. In the Middle East, Australia and Africa BFR levels were low in most indoor spaces. Asian countries also have the highest concentrations of TBBPA and HBCDD, followed by European countries. Fewer studies have been conducted measuring novel and emerging BFRs (NBFRs or EBFRs), of which decabromodiphenylethane (DBDPE) has the highest concentration in indoor environments, especially in China. The vast majority of children's exposure studies have been conducted in houses, sampling either dust or air, and considerably fewer in schools, daycare centers, cars and public facilities, despite BFR levels being comparable to (or sometimes even higher than) house dust. Relatively fewer studies focused on children's tissues such as serum, and only two studied exposure via mouthing toys. Alternative noninvasive sampling matrices that may act as surrogates for exposure to BFRs such as handwipes and silicone wristbands have recently started to gain momentum, because of the ease of sampling, faster collection time and better correlations to serum than house dust. Feces sampling is another promising alternative to children's serum that warrants further research. While many studies have associated different indoor environment characteristics, there is a knowledge gap on the association between children's behaviour and activity patterns and their exposure to BFRs, as well as data on infant exposure to BFRs via baby products. Results from the studies showed that dust ingestion was the dominant exposure pathway for most studied BFRs compared to indoor air inhalation and dermal contact, especially for infants and toddlers who have higher exposures than older children. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Fully Distributed Monitoring Architecture Supporting Multiple Trackees and Trackers in Indoor Mobile Asset Management Application

    PubMed Central

    Jeong, Seol Young; Jo, Hyeong Gon; Kang, Soon Ju

    2014-01-01

    A tracking service like asset management is essential in a dynamic hospital environment consisting of numerous mobile assets (e.g., wheelchairs or infusion pumps) that are continuously relocated throughout a hospital. The tracking service is accomplished based on the key technologies of an indoor location-based service (LBS), such as locating and monitoring multiple mobile targets inside a building in real time. An indoor LBS such as a tracking service entails numerous resource lookups being requested concurrently and frequently from several locations, as well as a network infrastructure requiring support for high scalability in indoor environments. A traditional centralized architecture needs to maintain a geographic map of the entire building or complex in its central server, which can cause low scalability and traffic congestion. This paper presents a self-organizing and fully distributed indoor mobile asset management (MAM) platform, and proposes an architecture for multiple trackees (such as mobile assets) and trackers based on the proposed distributed platform in real time. In order to verify the suggested platform, scalability performance according to increases in the number of concurrent lookups was evaluated in a real test bed. Tracking latency and traffic load ratio in the proposed tracking architecture was also evaluated. PMID:24662407

  9. HyMoTrack: A Mobile AR Navigation System for Complex Indoor Environments.

    PubMed

    Gerstweiler, Georg; Vonach, Emanuel; Kaufmann, Hannes

    2015-12-24

    Navigating in unknown big indoor environments with static 2D maps is a challenge, especially when time is a critical factor. In order to provide a mobile assistant, capable of supporting people while navigating in indoor locations, an accurate and reliable localization system is required in almost every corner of the building. We present a solution to this problem through a hybrid tracking system specifically designed for complex indoor spaces, which runs on mobile devices like smartphones or tablets. The developed algorithm only uses the available sensors built into standard mobile devices, especially the inertial sensors and the RGB camera. The combination of multiple optical tracking technologies, such as 2D natural features and features of more complex three-dimensional structures guarantees the robustness of the system. All processing is done locally and no network connection is needed. State-of-the-art indoor tracking approaches use mainly radio-frequency signals like Wi-Fi or Bluetooth for localizing a user. In contrast to these approaches, the main advantage of the developed system is the capability of delivering a continuous 3D position and orientation of the mobile device with centimeter accuracy. This makes it usable for localization and 3D augmentation purposes, e.g. navigation tasks or location-based information visualization.

  10. Indoor thermal environment, air exchange rates, and carbon dioxide concentrations before and after energy retro fits in Finnish and Lithuanian multi-family buildings.

    PubMed

    Leivo, Virpi; Prasauskas, Tadas; Du, Liuliu; Turunen, Mari; Kiviste, Mihkel; Aaltonen, Anu; Martuzevicius, Dainius; Haverinen-Shaughnessy, Ulla

    2018-04-15

    Impacts of energy retrofits on indoor thermal environment, i.e. temperature (T) and relative humidity (RH), as well as ventilation rates and carbon dioxide (CO 2 ) concentrations, were assessed in 46 Finnish and 20 Lithuanian multi-family buildings, including 39 retrofitted case buildings in Finland and 15 in Lithuania (the remaining buildings were control buildings with no retrofits). In the Finnish buildings, high indoor T along with low RH levels was commonly observed both before and after the retrofits. Ventilation rates (l/s per person) were higher after the retrofits in buildings with mechanical exhaust ventilation than the corresponding values before the retrofits. Measured CO 2 levels were low in vast majority of buildings. In Lithuania, average indoor T levels were low before the retrofits and there was a significant increase in the average T after the retrofits. In addition, average ventilation rate was lower and CO 2 levels were higher after the retrofits in the case buildings (N=15), both in apartments with natural and mixed ventilation. Based on the results, assessment of thermal conditions and ventilation rates after energy retrofits is crucial for optimal indoor environmental quality and energy use. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. HyMoTrack: A Mobile AR Navigation System for Complex Indoor Environments

    PubMed Central

    Gerstweiler, Georg; Vonach, Emanuel; Kaufmann, Hannes

    2015-01-01

    Navigating in unknown big indoor environments with static 2D maps is a challenge, especially when time is a critical factor. In order to provide a mobile assistant, capable of supporting people while navigating in indoor locations, an accurate and reliable localization system is required in almost every corner of the building. We present a solution to this problem through a hybrid tracking system specifically designed for complex indoor spaces, which runs on mobile devices like smartphones or tablets. The developed algorithm only uses the available sensors built into standard mobile devices, especially the inertial sensors and the RGB camera. The combination of multiple optical tracking technologies, such as 2D natural features and features of more complex three-dimensional structures guarantees the robustness of the system. All processing is done locally and no network connection is needed. State-of-the-art indoor tracking approaches use mainly radio-frequency signals like Wi-Fi or Bluetooth for localizing a user. In contrast to these approaches, the main advantage of the developed system is the capability of delivering a continuous 3D position and orientation of the mobile device with centimeter accuracy. This makes it usable for localization and 3D augmentation purposes, e.g. navigation tasks or location-based information visualization. PMID:26712755

  12. Effects of Indoor Air Pollutants on Atopic Dermatitis.

    PubMed

    Kim, JaKyoung; Kim, HyungJin; Lim, DaeHyun; Lee, Young-Kyu; Kim, Jeong Hee

    2016-12-09

    The increasing prevalence of atopic dermatitis (AD) is associated with variations in indoor environments. In Korea, many inner walls of homes are covered with wallpaper: such walls emit indoor air pollutants, including volatile organic compounds (VOCs) and formaldehyde. This randomized, double-blind study investigated the effects of wallpaper on indoor air quality and AD. Thirty-one children (aged three to eight years) with moderate AD were assigned to environmentally-friendly (EF) and polyvinyl chloride (PVC) wallpaper groups. Indoor air concentrations of VOCs, natural VOCs (NVOCs), formaldehyde, and total suspended bacteria were measured before and two (W₂) and eight weeks (W₈) after wallpapering. Scoring Atopic Dermatitis (SCORAD) evaluations and blood tests were performed during the same period. The EF wallpaper and PVC wallpaper groups showed similar trends in the changes in total VOCs (TVOC) and formaldehyde content in the indoor air. However, the EF wallpaper group showed more improvement on the SCORAD at W₂ and W₈ than the PVC wallpaper group. The SCORAD index was positively correlated with several indoor air pollutants. Further, the SCORAD index and NVOC % were negatively correlated. Improved SCORAD index and effects of wallpapering on indoor air quality improvements occurred within a short period of time in both groups. We believe that NVOCs in indoor air after EF wallpapering have a beneficial effect on health.

  13. Indoor mold, toxigenic fungi, and Stachybotrys chartarum: infectious disease perspective.

    PubMed

    Kuhn, D M; Ghannoum, M A

    2003-01-01

    Damp buildings often have a moldy smell or obvious mold growth; some molds are human pathogens. This has caused concern regarding health effects of moldy indoor environments and has resulted in many studies of moisture- and mold-damaged buildings. Recently, there have been reports of severe illness as a result of indoor mold exposure, particularly due to Stachybotrys chartarum. While many authors describe a direct relationship between fungal contamination and illness, close examination of the literature reveals a confusing picture. Here, we review the evidence regarding indoor mold exposure and mycotoxicosis, with an emphasis on S. chartarum. We also examine possible end-organ effects, including pulmonary, immunologic, neurologic, and oncologic disorders. We discuss the Cleveland infant idiopathic pulmonary hemorrhage reports in detail, since they provided important impetus for concerns about Stachybotrys. Some valid concerns exist regarding the relationship between indoor mold exposure and human disease. Review of the literature reveals certain fungus-disease associations in humans, including ergotism (Claviceps species), alimentary toxic aleukia (Fusarium), and liver disease (Aspergillys). While many papers suggest a similar relationship between Stachybotrys and human disease, the studies nearly uniformly suffer from significant methodological flaws, making their findings inconclusive. As a result, we have not found well-substantiated supportive evidence of serious illness due to Stachybotrys exposure in the contemporary environment. To address issues of indoor mold-related illness, there is an urgent need for studies using objective markers of illness, relevant animal models, proper epidemiologic techniques, and examination of confounding factors.

  14. Indoor Mold, Toxigenic Fungi, and Stachybotrys chartarum: Infectious Disease Perspective

    PubMed Central

    Kuhn, D. M.; Ghannoum, M. A.

    2003-01-01

    Damp buildings often have a moldy smell or obvious mold growth; some molds are human pathogens. This has caused concern regarding health effects of moldy indoor environments and has resulted in many studies of moisture- and mold-damaged buildings. Recently, there have been reports of severe illness as a result of indoor mold exposure, particularly due to Stachybotrys chartarum. While many authors describe a direct relationship between fungal contamination and illness, close examination of the literature reveals a confusing picture. Here, we review the evidence regarding indoor mold exposure and mycotoxicosis, with an emphasis on S. chartarum. We also examine possible end-organ effects, including pulmonary, immunologic, neurologic, and oncologic disorders. We discuss the Cleveland infant idiopathic pulmonary hemorrhage reports in detail, since they provided important impetus for concerns about Stachybotrys. Some valid concerns exist regarding the relationship between indoor mold exposure and human disease. Review of the literature reveals certain fungus-disease associations in humans, including ergotism (Claviceps species), alimentary toxic aleukia (Fusarium), and liver disease (Aspergillys). While many papers suggest a similar relationship between Stachybotrys and human disease, the studies nearly uniformly suffer from significant methodological flaws, making their findings inconclusive. As a result, we have not found well-substantiated supportive evidence of serious illness due to Stachybotrys exposure in the contemporary environment. To address issues of indoor mold-related illness, there is an urgent need for studies using objective markers of illness, relevant animal models, proper epidemiologic techniques, and examination of confounding factors. PMID:12525430

  15. Three-dimensional vapor intrusion modeling approach that combines wind and stack effects on indoor, atmospheric, and subsurface domains.

    PubMed

    Shirazi, Elham; Pennell, Kelly G

    2017-12-13

    Vapor intrusion (IV) exposure risks are difficult to characterize due to the role of atmospheric, building and subsurface processes. This study presents a three-dimensional VI model that extends the common subsurface fate and transport equations to incorporate wind and stack effects on indoor air pressure, building air exchange rate (AER) and indoor contaminant concentration to improve VI exposure risk estimates. The model incorporates three modeling programs: (1) COMSOL Multiphysics to model subsurface fate and transport processes, (2) CFD0 to model atmospheric air flow around the building, and (3) CONTAM to model indoor air quality. The combined VI model predicts AER values, zonal indoor air pressures and zonal indoor air contaminant concentrations as a function of wind speed, wind direction and outdoor and indoor temperature. Steady state modeling results for a single-story building with a basement demonstrate that wind speed, wind direction and opening locations in a building play important roles in changing the AER, indoor air pressure, and indoor air contaminant concentration. Calculated indoor air pressures ranged from approximately -10 Pa to +4 Pa depending on weather conditions and building characteristics. AER values, mass entry rates and indoor air concentrations vary depending on weather conditions and building characteristics. The presented modeling approach can be used to investigate the relationship between building features, AER, building pressures, soil gas concentrations, indoor air concentrations and VI exposure risks.

  16. Foliage Plants for Improving Indoor Air Quality

    NASA Technical Reports Server (NTRS)

    Wolverton, B. C.

    1988-01-01

    NASA's research with foliage houseplants during the past 10 years has produced a new concept in indoor air quality improvement. This new and exciting technology is quite simple. Both plant leaves and roots are utilized in removing trace levels of toxic vapors from inside tightly sealed buildings. Low levels of chemicals such as carbon monoxide and formaldehyde can be removed from indoor environments by plant leaves alone, while higher concentrations of numerous toxic chemicals can be removed by filtering indoor air through the plant roots surrounded by activated carbon. The activated carbon absorbs large quantities of the toxic chemicals and retains them until the plant roots and associated microorganisms degrade and assimilate these chemicals.

  17. A proposed UAV for indoor patient care.

    PubMed

    Todd, Catherine; Watfa, Mohamed; El Mouden, Yassine; Sahir, Sana; Ali, Afrah; Niavarani, Ali; Lutfi, Aoun; Copiaco, Abigail; Agarwal, Vaibhavi; Afsari, Kiyan; Johnathon, Chris; Okafor, Onyeka; Ayad, Marina

    2015-09-10

    Indoor flight, obstacle avoidance and client-server communication of an Unmanned Aerial Vehicle (UAV) raises several unique research challenges. This paper examines current methods and associated technologies adapted within the literature toward autonomous UAV flight, for consideration in a proposed system for indoor healthcare administration with a quadcopter. We introduce Healthbuddy, a unique research initiative towards overcoming challenges associated with indoor navigation, collision detection and avoidance, stability, wireless drone-server communications and automated decision support for patient care in a GPS-denied environment. To address the identified research deficits, a drone-based solution is presented. The solution is preliminary as we develop and refine the suggested algorithms and hardware system to achieve the research objectives.

  18. Study of indoor radon distribution using measurements and CFD modeling.

    PubMed

    Chauhan, Neetika; Chauhan, R P; Joshi, M; Agarwal, T K; Aggarwal, Praveen; Sahoo, B K

    2014-10-01

    Measurement and/or prediction of indoor radon ((222)Rn) concentration are important due to the impact of radon on indoor air quality and consequent inhalation hazard. In recent times, computational fluid dynamics (CFD) based modeling has become the cost effective replacement of experimental methods for the prediction and visualization of indoor pollutant distribution. The aim of this study is to implement CFD based modeling for studying indoor radon gas distribution. This study focuses on comparison of experimentally measured and CFD modeling predicted spatial distribution of radon concentration for a model test room. The key inputs for simulation viz. radon exhalation rate and ventilation rate were measured as a part of this study. Validation experiments were performed by measuring radon concentration at different locations of test room using active (continuous radon monitor) and passive (pin-hole dosimeters) techniques. Modeling predictions have been found to be reasonably matching with the measurement results. The validated model can be used to understand and study factors affecting indoor radon distribution for more realistic indoor environment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. A Three Year Study on 14 VOCs at One Site in Rome: Levels, Seasonal Variations, Indoor/Outdoor Ratio and Temporal Trends

    PubMed Central

    Fuselli, Sergio; De Felice, Marco; Morlino, Roberta; Turrio-Baldassarri, Luigi

    2010-01-01

    Fourteen volatile organic compounds (VOCs)—twelve hydrocarbons and two organochlorine compounds—were monitored both outdoors and indoors for three years at one site in Rome. Results showed that 118 out of 168 indoor seasonal mean values were higher than the corresponding outdoor concentrations. The most relevant source of outdoor hydrocarbons was automotive exhaust emissions. Due to the enforcement of various measures to protect health and the environment, outdoor levels of monoaromatic hydrocarbons decreased about ten fold over 15 years, and aliphatic hydrocarbons also decreased. With the decrease in these outdoor concentrations, indoor air sources are likely to be more relevant for indoor air exposures. Winter outdoor values for monoaromatic hydrocarbons were generally markedly higher than the summer ones. The gradual replacement of the current fleet of circulating cars with new cars complying with EURO 5 standards, further reducing hydrocarbon emissions, may possibly lead to an increase in the observed indoor/outdoor ratios. It is indeed more difficult to remove indoor sources, some of which are still unknown. PMID:21139860

  20. ASHRAE and residential ventilation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sherman, Max H.

    In the last quarter of a century, the western world has become increasingly aware of environmental threats to health and safety. During this period, people psychologically retreated away from outdoors hazards such as pesticides, smog, lead, oil spills, and dioxin to the seeming security of their homes. However, the indoor environment may not be healthier than the outdoor environment, as has become more apparent over the past few years with issues such as mold, formaldehyde, and sick-building syndrome. While the built human environment has changed substantially over the past 10,000 years, human biology has not; poor indoor air quality createsmore » health risks and can be uncomfortable. The human race has found, over time, that it is essential to manage the indoor environments of their homes. ASHRAE has long been in the business of ventilation, but most of the focus of that effort has been in the area of commercial and institutional buildings. Residential ventilation was traditionally not a major concern because it was felt that, between operable windows and envelope leakage, people were getting enough outside air in their homes. In the quarter of a century since the first oil shock, houses have gotten much more energy efficient. At the same time, the kinds of materials and functions in houses changed in character in response to people's needs. People became more environmentally conscious and aware not only about the resources they were consuming but about the environment in which they lived. All of these factors contributed to an increasing level of public concern about residential indoor air quality and ventilation. Where once there was an easy feeling about the residential indoor environment, there is now a desire to define levels of acceptability and performance. Many institutions--both public and private--have interests in Indoor Air Quality (IAQ), but ASHRAE, as the professional society that has had ventilation as part of its mission for over 100 years, is the logical place to provide leadership. This leadership has been demonstrated most recently by the publication of the first nationally recognized standard on ventilation in homes, ASHRAE Standard 62.2-2003, which builds on work that has been part of ASHRAE for many years and will presumably continue. Homeowners and occupants, which includes virtually all of us, will benefit from the application of Standard 62.2 and use of the top ten list. This activity is exactly the kind of benefit to society that the founders of ASHRAE envisioned and is consistent with ASHRAE's mission and vision. ASHRAE members should be proud of their Society for taking leadership in residential ventilation.« less

  1. How incense and joss paper burning during the worship activities influences ambient mercury concentrations in indoor and outdoor environments of an Asian temple?

    PubMed

    Shen, Huazhen; Tsai, Cheng-Mou; Yuan, Chung-Shin; Jen, Yi-Hsiu; Ie, Iau-Ren

    2017-01-01

    This study firstly investigated the species, concentration variation, and emission factors of mercury emitted from the burning of incenses and joss papers in an Asian temple. Both indoor and outdoor speciated mercury (GEM, GOM, and PHg) were sampled by manual samplers, while ambient GEM at an indoor site was in-situ monitored by a continuous GEM monitor. Field measurement results showed that the total atmospheric mercury (TAM) concentrations in indoor and outdoor environments were in the range of 8.03-35.72 and 6.03-31.35 ng/m 3 , respectively. The indoor and outdoor ratios (I/O) of TAM in the daytime and at nighttime were in the range of 0.64-0.90 and 1.50-2.04, respectively. The concentrations of GEM, GOM, and PHg during the holiday periods were approximately 1-4 times higher than those during the non-holiday periods. GEM was the dominant mercury species in the indoor and outdoor environments and accounted for 63-81% of TAM, while the oxidized mercury accounted for 19-37% of TAM. Burning incenses and joss papers in a combustion chamber showed that the concentration of GEM from joss paper burning ranged from 4.07 to 11.62 μg/m 3 , or about 13.97 times higher than that of incense burning, while the concentration of PHg from incense burning ranged from 95.91 to 135.07 ng/m 3 , or about 3.29 times higher than that of joss paper burning. The emission factors of incense burning were 10.39 ng/g of GEM and 1.40 ng/g of PHg, while those of joss paper burning were 12.65 ng/g of GEM and 1.27 ng/g of PHg, respectively. This study revealed that speciated mercury emitted from worship activities had significant influence on the indoor and outdoor mercury concentrations in an Asian temple. Higher intensity of worship activities during holidays resulted in a higher concentration of speciated mercury in indoor and outdoor air, which might cause health threats to worshipers, staffs, and surrounding inhabitants through long-term exposure. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Indoor air humidity, air quality, and health - An overview.

    PubMed

    Wolkoff, Peder

    2018-04-01

    There is a long-standing dispute about indoor air humidity and perceived indoor air quality (IAQ) and associated health effects. Complaints about sensory irritation in eyes and upper airways are generally among top-two symptoms together with the perception "dry air" in office environments. This calls for an integrated analysis of indoor air humidity and eye and airway health effects. This overview has reviewed the literature about the effects of extended exposure to low humidity on perceived IAQ, sensory irritation symptoms in eyes and airways, work performance, sleep quality, virus survival, and voice disruption. Elevation of the indoor air humidity may positively impact perceived IAQ, eye symptomatology, and possibly work performance in the office environment; however, mice inhalation studies do not show exacerbation of sensory irritation in the airways by low humidity. Elevated humidified indoor air appears to reduce nasal symptoms in patients suffering from obstructive apnea syndrome, while no clear improvement on voice production has been identified, except for those with vocal fatigue. Both low and high RH, and perhaps even better absolute humidity (water vapor), favors transmission and survival of influenza virus in many studies, but the relationship between temperature, humidity, and the virus and aerosol dynamics is complex, which in the end depends on the individual virus type and its physical/chemical properties. Dry and humid air perception continues to be reported in offices and in residential areas, despite the IAQ parameter "dry air" (or "wet/humid air") is semantically misleading, because a sensory organ for humidity is non-existing in humans. This IAQ parameter appears to reflect different perceptions among other odor, dustiness, and possibly exacerbated by desiccation effect of low air humidity. It is salient to distinguish between indoor air humidity (relative or absolute) near the breathing and ocular zone and phenomena caused by moisture-damage of the building construction and emissions therefrom. Further, residential versus public environments should be considered as separate entities with different characteristics and demands of humidity. Research is needed about particle, bacteria and virus dynamics indoors for improvement of quality of life and with more focus on the impact of absolute humidity. "Dry (or wet) air" should be redefined to become a meaningful IAQ descriptor. Copyright © 2018 The Author. Published by Elsevier GmbH.. All rights reserved.

  3. User's Guide and Download for IECCU- Indoor Environmental Concentrations in Buildings with Conditioned and Unconditioned Zones

    EPA Pesticide Factsheets

    This program serves two purposes: (1) as a general-purpose indoor exposure model in buildings with multiple zones, multiple chemicals and multiple sources and sinks, and (2) as a special-purpose concentration model

  4. Indoor and outdoor elemental mercury: a comparison of three different cases.

    PubMed

    Loupa, G; Polyzou, C; Zarogianni, A M; Ouzounis, K; Rapsomanikis, S

    2017-02-01

    Gaseous elemental mercury (GEM) concentrations were determined in three different indoor environments: an office in a building with no indoor sources of mercury (Bldg. I), an office affected by indoor mercury emissions from an adjacent laboratory (Bldg. II), and finally, an office where an outdoor mercury spill occurred accidentally (Bldg. III). The maximum recorded indoor GEM concentrations, with the largest variation in time, were observed in Bldg. II, with a continuous indoor mercury source (lower to upper quartile 15 to 62 ng m -3 ). The lowest values were recorded in Bldg. I (lower to upper quartile 3 to 5 ng m -3 ), where indoor GEM levels were affected mainly by the exhaust of vehicles in the parking lot of the building. The monitoring of GEM indoors (lower to upper quartile 15 to 42 ng m -3 ), and outdoors (in several heights) of the Bldg. III, revealed that the cleaning up procedure that followed the spill was not adequate. Auxiliary measurements in the first two cases were the indoor microclimatic conditions, as well as the indoor CO 2 concentrations, and in the third case the outdoor meteorological data. The exhaust of vehicles, the chemical reagents, and an outdoor mercury spill were found to mainly affect the observed indoor GEM levels. People in Bldg. II and people walking through the area, where Hg 0 was spilled, were found to be exposed to concentrations above some guide values.

  5. Sources of halogenated brominated retardants in house dust in an industrial city in southern China and associated human exposure.

    PubMed

    Chen, She-Jun; Ding, Nan; Zhu, Zhi-Cheng; Tian, Mi; Luo, Xiao-Jun; Mai, Bi-Xian

    2014-11-01

    Halogenated flame retardants (HFRs) are a class of ubiquitous pollutants in the environment and attract increasing attention. In the present study, HFR concentrations were measured in indoor and outdoor dust in an important industrial city (Dongguan) in southern China, in which their presence and associated human exposure are unknown. The HFRs were dominated by polybrominated diphenyl ethers (PBDEs) and decabromodiphenyl ethane (DBDPE), with mean concentrations of 2365 and 2441 ng/g in the indoor dust, respectively, which were 2-3 order of magnitude higher the concentrations of other HFRs. However elevated tri- to hepta-BDE concentrations (869 ng/g) were found in Houjie Town, a furniture manufacturing center. The mean indoor/outdoor (I/O) ratios of HFR concentrations in the dust were all larger than one (1.55-16.4), suggesting the importance of indoors sources for HFRs in indoor dust in this industrial city. Principal component analysis (PCA) showed that the correlations among the HFRs in the indoor dust probably revealed differences in their commercial applications, while most HFRs in the outdoor dust have similar sources except for phased-out BDE47 and 99. The compositions of lower brominated PBDEs varied among the towns, probably due to their different sources or influence of photo-degradation. Nevertheless, the similar composition of highly brominated congeners indicated little photo-degradation encountered in the ambient environment. The non-cancer risk associated with indoor dust ingestion is low for the general population in Dongguan, but some children in the furniture manufacturing center have significantly high risk of exposure to banned PBDEs. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Use of integrated indoor concentrations of tracer gases and volatile organic compounds to distinguish soil sources from above-ground sources

    EPA Science Inventory

    Vapor intrusion refers to the situation in which harmful chemicals [such as halogenated or chlorinated volatile organic compounds (VOC) or petroleum products] in the groundwater or soil volatilize in the vadose zone and migrate into the indoor environment. These chemicals typical...

  7. A framework for modeling non-steady-state concentrations of semivolatile organic compounds indoors ― II. Interactions with particulate matter

    EPA Science Inventory

    This paper describes a method for dynamic modeling of the interactions of semivolatile organic compounds (SVOCs) with airborne and settled particulate matter in the indoor environment. This method is fully compatible with the other components within the framework. Despite the unc...

  8. Preschool Teachers' Views on Schools' Indoor and Outdoor Environment Safety

    ERIC Educational Resources Information Center

    Konakli, Tugba; Ülçetin, Esra

    2016-01-01

    The aim of this research is to analyze opinions of teachers who work in preschool education institutions concerning precautions that should be taken for indoor and outdoor security. Study group of this research is determined by criterion sampling from purposeful sampling techniques. The study group of this research is consist of eight preschool…

  9. Elemental mercury emission in the indoor environment due to broken compact fluorescent light (CFL) bulbs--paper

    EPA Science Inventory

    Compact fluorescent light (CFL) bulbs contain a few milligrams (mg) of elemental mercury. When a CFL breaks, some of the mercury is immediately released as elemental mercury vapor and the remainder is deposited on indoor surfaces with the bulb debris. In a controlled study design...

  10. BUILDING FEATURES THAT INFLUENCE THE PENETRATION OF TOXIC GASES FROM THE AMBIENT TO THE INDOOR ENVIRONMENT

    EPA Science Inventory

    Strategies to reduce indoor exposures to certain toxic air contaminants suggested a study of the penetration of these toxics from the external atmosphere into an unoccupied research house. The mass balance method is applied to measure rates of sorption and re-emission of the con...

  11. WLAN Positioning Methods and Supporting Learning Technologies for Mobile Platforms

    ERIC Educational Resources Information Center

    Melkonyan, Arsen

    2013-01-01

    Location technologies constitute an essential component of systems design for autonomous operations and control. The Global Positioning System (GPS) works well in outdoor areas, but the satellite signals are not strong enough to penetrate inside most indoor environments. As a result, a new strain of indoor positioning technologies that make use of…

  12. Impact of simulated climate and building features on the penetration of toxic gases from the ambient into the indoor environment

    EPA Science Inventory

    This research is a combination of experimental results and analysis of formaldehyde penetration across a residential building envelope with the objective of developing an understanding of the factors that govern indoor air concentrations of air toxics and to provide linkages betw...

  13. Polybrominated diphenyl ethers in indoor air in Kuwait: Implications for human exposure

    NASA Astrophysics Data System (ADS)

    Gevao, Bondi; Al-Bahloul, Majed; Al-Ghadban, Abdul Nabi; Ali, Lulwa; Al-Omair, Ali; Helaleh, Murad; Al-Matrouk, Khaled; Zafar, Jamal

    Polyurethane foam plug passive samplers were used to concurrently measure air concentrations of polybrominated diphenyl ethers (PBDEs) in 70 indoor environments. PBDEs were detected in all homes and offices investigated with patterns similar to the distribution in the commercial penta technical formulation (Bromkal 70-5DE). The ubiquitous distribution of these compounds in indoor environments may be due to the volatilization of these chemicals from foam (e.g. mattresses, foam padded furniture), electronic equipments (e.g. TVs, printers, computers) and other consumer products to which they are added as flame retardants. Mean ΣPBDEs concentration in air was log-normally distributed and ranged from ˜2-385 pg m -3. Using an inhalation rate of 8 and 20 m 3 day -1 for children and adults respectively, exposure via inhalation is estimated to be 173 and 399 pg day -1 for children and adults respectively. This study supports the growing body of evidence for the ubiquitous presence of these compounds in indoor air and the potential for continuous, low-level exposure both at work and home.

  14. Exoskeletons and economics: indoor arthropod diversity increases in affluent neighbourhoods.

    PubMed

    Leong, Misha; Bertone, Matthew A; Bayless, Keith M; Dunn, Robert R; Trautwein, Michelle D

    2016-08-01

    In urban ecosystems, socioeconomics contribute to patterns of biodiversity. The 'luxury effect', in which wealthier neighbourhoods are more biologically diverse, has been observed for plants, birds, bats and lizards. Here, we used data from a survey of indoor arthropod diversity (defined throughout as family-level richness) from 50 urban houses and found that house size, surrounding vegetation, as well as mean neighbourhood income best predict the number of kinds of arthropods found indoors. Our finding, that homes in wealthier neighbourhoods host higher indoor arthropod diversity (consisting of primarily non-pest species), shows that the luxury effect can extend to the indoor environment. The effect of mean neighbourhood income on indoor arthropod diversity was particularly strong for individual houses that lacked high surrounding vegetation ground cover, suggesting that neighbourhood dynamics can compensate for local choices of homeowners. Our work suggests that the management of neighbourhoods and cities can have effects on biodiversity that can extend from trees and birds all the way to the arthropod life in bedrooms and basements. © 2016 The Authors.

  15. Exoskeletons and economics: indoor arthropod diversity increases in affluent neighbourhoods

    PubMed Central

    Bertone, Matthew A.; Bayless, Keith M.; Dunn, Robert R.; Trautwein, Michelle D.

    2016-01-01

    In urban ecosystems, socioeconomics contribute to patterns of biodiversity. The ‘luxury effect’, in which wealthier neighbourhoods are more biologically diverse, has been observed for plants, birds, bats and lizards. Here, we used data from a survey of indoor arthropod diversity (defined throughout as family-level richness) from 50 urban houses and found that house size, surrounding vegetation, as well as mean neighbourhood income best predict the number of kinds of arthropods found indoors. Our finding, that homes in wealthier neighbourhoods host higher indoor arthropod diversity (consisting of primarily non-pest species), shows that the luxury effect can extend to the indoor environment. The effect of mean neighbourhood income on indoor arthropod diversity was particularly strong for individual houses that lacked high surrounding vegetation ground cover, suggesting that neighbourhood dynamics can compensate for local choices of homeowners. Our work suggests that the management of neighbourhoods and cities can have effects on biodiversity that can extend from trees and birds all the way to the arthropod life in bedrooms and basements. PMID:27484644

  16. Indoor radio measurement and planning for UMTS/HSDPA with antennas

    NASA Astrophysics Data System (ADS)

    Eheduru, Marcellinus

    Over the last decade, mobile communication networks have evolved tremendously with a key focus on providing high speed data services in addition to voice. The third generation of mobile networks in the form of Universal Mobile Telecommunications System (UMTS) is already offering revolutionary mobile broadband experience to its users by deploying High Speed Downlink Packet Access (HSDPA) as its packet-data technology. With data speeds up to 14.4 Mbps and ubiquitous mobility, HSDPA is anticipated to become a preferred broadband access medium for end-users via mobile phones, laptops etc. While majority of these end-users are located indoors most of the time, approximately 70-80% of the HSDPA traffic is estimated to originate from inside buildings. Thus for network operators, indoor coverage has become a necessity for technical and business reasons. Macro-cellular (outdoor) to indoor coverage is a natural inexpensive way of providing network coverage inside the buildings. However, it does not guarantee sufficient link quality required for optimal HSDPA operation. On the contrary, deploying a dedicated indoor system may be far too expensive from an operator's point of view. In this thesis, the concept is laid for the understanding of indoor radio wave propagation in a campus building environment which could be used to plan and improve outdoor-to-indoor UMTS/HSDPA radio propagation performance. It will be shown that indoor range performance depends not only on the transmit power of an indoor antenna, but also on the product's response to multipath and obstructions in the environment along the radio propagation path. An extensive measurement campaign will be executed in different indoor environments analogous to easy, medium and hard radio conditions. The effects of walls, ceilings, doors and other obstacles on measurement results would be observed. Chapter one gives a brief introduction to the evolution of UMTS and HSDPA. It goes on to talk about radio wave propagation and some important properties of antennas which must be considered when choosing an antenna for indoor radio propagation. The challenges of in-building network coverage and also the objectives of this thesis are also mentioned in this chapter. The evolution and standardization, network architecture, radio features and most importantly, the radio resource management features of UMTS/HSDPA are given in chapter two. In this chapter, the reason why Wideband Code Division Multiple Access (WCDMA) was specified and selected for 3G (UMTS) systems would be seen. The architecture of the radio access network, interfaces with the radio access network between base stations and radio network controllers (RNC), and the interface between the radio access network and the core network are also described in this chapter. The main features of HSDPA are mentioned at the end of the chapter. In chapter three the principles of the WCDMA air interface, including spreading, Rake reception, signal fading, power control and handovers are introduced. The different types and characteristics of the propagation environments and how they influence radio wave propagation are mentioned. UMTS transport, logical and physical channels are also mentioned, highlighting their significance and relationship in and with the network. Radio network planning for UMTS is discussed in chapter four. The outdoor planning process which includes dimensioning, detailed planning, optimization and monitoring is outlined. Indoor radio planning with distributed antenna systems (DAS), which is the idea and motivation behind this thesis work, is also discussed. The various antennas considered and the antenna that was selected for this thesis experiment was discussed in chapter five. The antenna radiation pattern, directivity, gain and input impedance were the properties of the antenna that were taken into consideration. The importance of the choice of the antenna for any particular type of indoor environment is also mentioned. In chapter six, the design and fabrication of the monopole antennas used for the experimental measurement is mentioned. The procedure for measurement and the equipment used are also discussed. The results gotten from the experiment are finally analyzed and discussed. In this chapter the effect of walls, floors, doors, ceilings and other obstacles on radio wave propagation will be seen. Finally, chapter seven concludes this thesis work and gives some directions for future work.

  17. Calibration of LR-115 for 222Rn monitoring taking into account the plateout effect.

    PubMed

    Da Silva, A A R; Yoshimura, E M

    2003-01-01

    The dose received by people exposed to indoor radon is mainly due to radon progeny. This fact points to the establishment of techniques that access either radon and progeny together, or only radon progeny concentration. In this work a low cost and easy to use methodology is presented to determine the total indoor alpha emission concentration. It is based on passive detection using LR-115 and CR-39 detectors, taking into account the plateout effect. A calibration of LR-115 track density response was done by indoor exposure in controlled environments and dwellings, places where 222Rn and progeny concentration were measured with CR-39. The calibration factor obtained showed great dependence on the ambient condition: (0.69 +/- 0.04) cm for controlled environments and (0.43 +/- 0.03) cm for dwellings.

  18. Lidar-based door and stair detection from a mobile robot

    NASA Astrophysics Data System (ADS)

    Bansal, Mayank; Southall, Ben; Matei, Bogdan; Eledath, Jayan; Sawhney, Harpreet

    2010-04-01

    We present an on-the-move LIDAR-based object detection system for autonomous and semi-autonomous unmanned vehicle systems. In this paper we make several contributions: (i) we describe an algorithm for real-time detection of objects such as doors and stairs in indoor environments; (ii) we describe efficient data structures and algorithms for processing 3D point clouds acquired by laser scanners in a streaming manner, which minimize the memory copying and access. We show qualitative results demonstrating the effectiveness of our approach on runs in an indoor office environment.

  19. Do indoor pollutants and thermal conditions in schools influence student performance? A critical review of the literature.

    PubMed

    Mendell, M J; Heath, G A

    2005-02-01

    To assess whether school environments can adversely affect academic performance, we review scientific evidence relating indoor pollutants and thermal conditions, in schools or other indoor environments, to human performance or attendance. We critically review evidence for direct associations between these aspects of indoor environmental quality (IEQ) and performance or attendance. Secondarily, we summarize, without critique, evidence on indirect connections potentially linking IEQ to performance or attendance. Regarding direct associations, little strongly designed research was available. Persuasive evidence links higher indoor concentrations of NO(2) to reduced school attendance, and suggestive evidence links low ventilation rates to reduced performance. Regarding indirect associations, many studies link indoor dampness and microbiologic pollutants (primarily in homes) to asthma exacerbations and respiratory infections, which in turn have been related to reduced performance and attendance. Also, much evidence links poor IEQ (e.g. low ventilation rate, excess moisture, or formaldehyde) with adverse health effects in children and adults and documents dampness problems and inadequate ventilation as common in schools. Overall, evidence suggests that poor IEQ in schools is common and adversely influences the performance and attendance of students, primarily through health effects from indoor pollutants. Evidence is available to justify (i) immediate actions to assess and improve IEQ in schools and (ii) focused research to guide IEQ improvements in schools. There is more justification now for improving IEQ in schools to reduce health risks to students than to reduce performance or attendance risks. However, as IEQ-performance links are likely to operate largely through effects of IEQ on health, IEQ improvements that benefit the health of students are likely to have performance and attendance benefits as well. Immediate actions are warranted in schools to prevent dampness problems, inadequate ventilation, and excess indoor exposures to substances such as NO(2) and formaldehyde. Also, siting of new schools in areas with lower outdoor pollutant levels is preferable.

  20. Effects of an ozone-generating air purifier on indoor secondary particles in three residential dwellings.

    PubMed

    Hubbard, H F; Coleman, B K; Sarwar, G; Corsi, R L

    2005-12-01

    The use of indoor ozone generators as air purifiers has steadily increased over the past decade. Many ozone generators are marketed to consumers for their ability to eliminate odors and microbial agents and to improve health. In addition to the harmful effects of ozone, recent studies have shown that heterogeneous and homogeneous reactions between ozone and some unsaturated hydrocarbons can be an important source of indoor secondary pollutants, including free radicals, carbonyls, carboxylic acids, and fine particles. Experiments were conducted in one apartment and two detached single-family dwellings in Austin, TX, to assess the effects of an ozone generator on indoor secondary organic aerosol concentrations in actual residential settings. Ozone was generated using a commercial ozone generator marketed as an air purifier, and particle measurements were recorded before, during, and after the release of terpenes from a pine oil-based cleaning product. Particle number concentration, ozone concentration, and air exchange rate were measured during each experiment. Particle number and mass concentrations increased when both terpenes and ozone were present at elevated levels. Experimental results indicate that ozone generators in the presence of terpene sources facilitate the growth of indoor fine particles in residential indoor atmospheres. Human exposure to secondary organic particles can be reduced by minimizing the intentional release of ozone, particularly in the presence of terpene sources. Past studies have shown that ozone-initiated indoor chemistry can lead to elevated concentrations of fine particulate matter, but have generally been completed in controlled laboratory environments and office buildings. We explored the effects of an explicit ozone generator marketed as an air purifier on the formation of secondary organic aerosol mass in actual residential indoor settings. Results indicate significant increases in number and mass concentrations for particles <0.7 microns in diameter, particularly when an ozone generator is used in the presence of a terpene source such as a pine oil-based cleaner. These results add evidence to the potentially harmful effects of ozone generation in residential environments.

  1. Socioeconomic and Outdoor Meteorological Determinants of Indoor Temperature and Humidity in New York City Dwellings

    PubMed Central

    Tamerius, JD; Perzanowski, MS; Acosta, LM; Jacobson, JS; Goldstein, IF; Quinn, JW; Rundle, AG; Shaman, J

    2013-01-01

    Background Numerous mechanisms link outdoor weather and climate conditions to human health. It is likely that many health conditions are more directly affected by indoor rather than outdoor conditions. Yet, the relationship between indoor temperature and humidity conditions to outdoor variability, and the heterogeneity of the relationship among different indoor environments are largely unknown. Methods We use 5–14 day measures of indoor temperature and relative humidity from 327 dwellings in New York City for the years 2008–2011 to investigate the relationship between indoor climate, outdoor meteorological conditions, socioeconomic conditions, and building descriptors. Study households were primarily middle-income and located across the boroughs of Brooklyn, Queens, Bronx, and Manhattan. Results Indoor temperatures are positively associated with outdoor temperature during the warm season and study dwellings in higher socioeconomic status neighborhoods are significantly cooler. During the cool season, outdoor temperatures have little effect on indoor temperatures; however, indoor temperatures can range more than 10 °C between dwellings despite similar outdoor temperatures. Apartment buildings tend to be significantly warmer than houses and dwellings on higher floors are also significantly warmer than dwellings on lower floors. Outdoor specific humidity is positively associated with indoor specific and relative humidity, but there is no consistent relationship between outdoor and indoor relative humidity. Conclusions In New York City, the relationship between indoor and outdoor temperature and humidity conditions vary significantly between dwellings. These results can be used to inform studies of health outcomes for which temperature or humidity is an established factor affecting human health and highlights the need for more research on the determinants of indoor climate. PMID:24077420

  2. THE RELATIONSHIP BETWEEN SOCIAL, POLICY AND PHYSICAL VENUE FEATURES AND SOCIAL COHESION ON CONDOM USE FOR PREGNANCY PREVENTION AMONG SEX WORKERS: A SAFER INDOOR WORK ENVIRONMENT SCALE

    PubMed Central

    Duff, Putu; Shoveller, Jean; Dobrer, Sabina; Ogilvie, Gina; Montaner, Julio; Chettiar, Jill; Shannon, Kate

    2015-01-01

    Background This study aims to: report on a newly developed ‘Safer Indoor Work Environmental Scale’ that characterizes the social, policy and physical features of indoor venues and social cohesion; and using this scale, longitudinally evaluate the association between these features on sex workers’ (SWs’) condom use for pregnancy prevention. Methods Drawing on a prospective open cohort of female SWs working in indoor venues, a newly-developed ‘Safer Indoor Work Environment Scale’ was used to build six multivariable models with generalized estimating equations (GEE), to determine the independent effects of social, policy and venue-based features and social cohesion on condom use. Results Of 588 indoor SWs, 63.6% used condoms for pregnancy prevention in the last month. In multivariable GEE analysis, the following venue-based features were significantly correlated with barrier contraceptive use for pregnancy prevention: managerial practices and venue safety policies (Adjusted Odds Ratio (AOR)=1.09; 95% Confidence Interval (95%CI) 1.01–1.17) access to sexual and reproductive health services/supplies (AOR=1.10; 95%CI 1.00–1.20) access to drug harm reduction (AOR=1.13; 95%CI 1.01–1.28), and social cohesion among workers (AOR=1.05; 95%CI 1.03–1.07). Access to security features was marginally associated with condom use (AOR=1.13; 95%CI 0.99–1.29). Conclusion The findings of the current study highlight how work environment and social cohesion among SWs are related to improved condom use. Given global calls for the decriminalization of sex work, and potential legislative reforms in Canada, this study points to the critical need for new institutional arrangements (e.g., legal and regulatory frameworks; labour standards) to support safer sex workplaces. PMID:25678713

  3. The relationship between social, policy and physical venue features and social cohesion on condom use for pregnancy prevention among sex workers: a safer indoor work environment scale.

    PubMed

    Duff, Putu; Shoveller, Jean; Dobrer, Sabina; Ogilvie, Gina; Montaner, Julio; Chettiar, Jill; Shannon, Kate

    2015-07-01

    This study aims to report on a newly developed Safer Indoor Work Environmental Scale that characterises the social, policy and physical features of indoor venues and social cohesion; and using this scale, longitudinally evaluate the association between these features on sex workers' (SWs') condom use for pregnancy prevention. Drawing on a prospective open cohort of female SWs working in indoor venues, a newly developed Safer Indoor Work Environment Scale was used to build six multivariable models with generalised estimating equations (GEE), to determine the independent effects of social, policy and physical venue-based features and social cohesion on condom use. Of 588 indoor SWs, 63.6% used condoms for pregnancy prevention in the last month. In multivariable GEE analysis, the following venue-based features were significantly correlated with barrier contraceptive use for pregnancy prevention: managerial practices and venue safety policies (adjusted OR (AOR)=1.09; 95% CI 1.01 to 1.17), access to sexual and reproductive health services/supplies (AOR=1.10; 95% CI 1.00 to 1.20), access to drug harm reduction (AOR=1.13; 95% CI 1.01 to 1.28) and social cohesion among workers (AOR=1.05; 95% CI 1.03 to 1.07). Access to security features was marginally associated with condom use (AOR=1.13; 95% CI 0.99 to 1.29). The findings of the current study highlight how work environment and social cohesion among SWs are related to improved condom use. Given global calls for the decriminalisation of sex work, and potential legislative reforms in Canada, this study points to the critical need for new institutional arrangements (eg, legal and regulatory frameworks; labour standards) to support safer sex workplaces. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  4. TESTING INDOOR AIR PRODUCTS: ONE APPROACH TO DEVELOPING WIDELY ACCEPTED PROTOCOLS

    EPA Science Inventory

    The paper describes an approach to developing widely acce ted products for testing indoor air products. [NOTE: Research Triangle Institute (RTI) is a partner in the U.S. Environmental Protection Agency's (EPA's) Environmental Technology Verification (ETV) Program with responsibil...

  5. A Guide to Lowering Test Scores.

    ERIC Educational Resources Information Center

    Rosenblum, Shelly; Spark, Barbara

    2002-01-01

    Discusses the adverse impact of poor classroom air quality on student performance and how school officials can eliminate the sources of indoor air pollution. Describes Environmental Protection Agency's "Indoor Air Quality Tools for Schools" program downloadable at www.epa.gov/iaq/schools/index.html. (PKP)

  6. Gait Event Detection in Real-World Environment for Long-Term Applications: Incorporating Domain Knowledge Into Time-Frequency Analysis.

    PubMed

    Khandelwal, Siddhartha; Wickstrom, Nicholas

    2016-12-01

    Detecting gait events is the key to many gait analysis applications that would benefit from continuous monitoring or long-term analysis. Most gait event detection algorithms using wearable sensors that offer a potential for use in daily living have been developed from data collected in controlled indoor experiments. However, for real-word applications, it is essential that the analysis is carried out in humans' natural environment; that involves different gait speeds, changing walking terrains, varying surface inclinations and regular turns among other factors. Existing domain knowledge in the form of principles or underlying fundamental gait relationships can be utilized to drive and support the data analysis in order to develop robust algorithms that can tackle real-world challenges in gait analysis. This paper presents a novel approach that exhibits how domain knowledge about human gait can be incorporated into time-frequency analysis to detect gait events from long-term accelerometer signals. The accuracy and robustness of the proposed algorithm are validated by experiments done in indoor and outdoor environments with approximately 93 600 gait events in total. The proposed algorithm exhibits consistently high performance scores across all datasets in both, indoor and outdoor environments.

  7. Quantification of differences between occupancy and total monitoring periods for better assessment of exposure to particles in indoor environments

    NASA Astrophysics Data System (ADS)

    Wierzbicka, A.; Bohgard, M.; Pagels, J. H.; Dahl, A.; Löndahl, J.; Hussein, T.; Swietlicki, E.; Gudmundsson, A.

    2015-04-01

    For the assessment of personal exposure, information about the concentration of pollutants when people are in given indoor environments (occupancy time) are of prime importance. However this kind of data frequently is not reported. The aim of this study was to assess differences in particle characteristics between occupancy time and the total monitoring period, with the latter being the most frequently used averaging time in the published data. Seven indoor environments were selected in Sweden and Finland: an apartment, two houses, two schools, a supermarket, and a restaurant. They were assessed for particle number and mass concentrations and number size distributions. The measurements using a Scanning Mobility Particle Sizer and two photometers were conducted for seven consecutive days during winter in each location. Particle concentrations in residences and schools were, as expected, the highest during occupancy time. In the apartment average and median PM2.5 mass concentrations during the occupancy time were 29% and 17% higher, respectively compared to total monitoring period. In both schools, the average and medium values of the PM2.5 mass concentrations were on average higher during teaching hours compared to the total monitoring period by 16% and 32%, respectively. When it comes to particle number concentrations (PNC), in the apartment during occupancy, the average and median values were 33% and 58% higher, respectively than during the total monitoring period. In both houses and schools the average and median PNC were similar for the occupancy and total monitoring periods. General conclusions on the basis of measurements in the limited number of indoor environments cannot be drawn. However the results confirm a strong dependence on type and frequency of indoor activities that generate particles and site specificity. The results also indicate that the exclusion of data series during non-occupancy periods can improve the estimates of particle concentrations and characteristics suitable for exposure assessment, which is crucial for estimating health effects in epidemiological and toxicological studies.

  8. Performance evaluation of an in situ nitrous acid measurement system and continuous measurement of nitrous acid in an indoor environment.

    PubMed

    Park, Seung Shik; Cho, Sung Yong

    2010-12-01

    Nitrous acid (HONO) may cause adverse effects to mucous membranes and lung function when people are exposed to higher HONO concentrations than those present in typical indoor residential environments. Therefore, determination of HONO concentration in indoor environments is required to investigate occurrences of high HONO levels. In this work, a high-time-resolution measurement system was utilized to better understand the levels and dynamic behavior of HONO in an indoor environment. The performance of the in situ HONO analyzer applied to this work was evaluated using a 12-hr integrated annular denuder technique under ambient conditions. Both methods for the measurements of HONO were in good agreement, with a regression slope of 0.84, an intercept of 0.09, and correlation coefficient (r2) of 0.67. Indoor HONO and nitrogen oxide concentrations were also observed for approximately 5 days in winter in the living room of an apartment that had a gas range for cooking in the kitchen. Investigation of the relationships among nitric oxide (NO), nitrite (NO2), and HONO concentrations suggests that HONO production during combustion could be the result of direct emission, whereas the heterogeneous NO2 chemistry during the background period and after combustion was the possible pathway of HONO production. Controlled combustion experiments, performed at a burning rate of 50% valve setting, show peak HONO concentrations during the unvented combustion to be approximately 8-10 times higher than background levels depending on the time of day. At a burning rate setting of 50%, the peak concentration of HONO during unvented combustion was found to be 33-37% higher than those from "weak" (airflow = 340 m3/hr) and "strong" (airflow = 540 m3/hr) vented combustions. The decay rate of the HONO concentrations for the unvented combustion conditions was approximately 2-fold higher in the daytime than in the nighttime and significantly less than those of NO and NO2.

  9. Source apportionment of indoor, outdoor and personal PM2.5 exposure of pregnant women in Barcelona, Spain

    NASA Astrophysics Data System (ADS)

    Minguillón, M. C.; Schembari, A.; Triguero-Mas, M.; de Nazelle, A.; Dadvand, P.; Figueras, F.; Salvado, J. A.; Grimalt, J. O.; Nieuwenhuijsen, M.; Querol, X.

    2012-11-01

    Exposure to air pollution has been shown to adversely affect foetal development in the case of pregnant women. The present study aims to investigate the PM composition and sources influencing personal exposure of pregnant women in Barcelona. To this end, indoor, outdoor and personal exposure measurements were carried out for a selection of 54 pregnant women between November 2008 and November 2009. PM2.5 samples were collected during two consecutive days and then analysed for black smoke (BS), major and trace elements, and polycyclic aromatic hydrocarbons (PAHs) concentrations. Personal information such as commuting patterns and cosmetics use was also collected. PM2.5 concentrations were higher for personal samples than for indoor and outdoor environments. Indoor, outdoor and personal BS and sulphate concentrations were strongly correlated, although some specific indoor and outdoor sulphate sources may exist. Average trace elements concentrations were similar indoor, outdoor and for personal exposure, but the correlations were moderate for most of them. Most of the PAHs concentrations showed strong correlations indoor-outdoor. A source apportionment analysis of the PM composition data by means of a Positive Matrix Factorization (PMF) resulted in the identification of six sources for the outdoor and indoor environments: secondary sulphate, fueloil + sea salt (characterized by V, Ni, Na and Mg), mineral, cigarette (characterized by K, Ce, Cd, benzo(k)fluoranthene and benzo(ghi)perylene), road traffic (characterized by BS and low weight PAHs), and industrial (characterized by Pb, Sn, Cu, Mn and Fe). For personal exposure two specific sources were found: cosmetics (characterized by abundance of Ca, Li, Ti and Sr and the absence of Al) and train/subway (characterized by Fe, Mn, Cu and Ba). The contribution of the sources varied widely among women, especially for cigarette (from zero to up to 4 μg m-3), train/subway (up to more than 6 μg m-3) and cosmetics (up to more than 5 μg m-3). The source contributions showed generally strong correlations indoor-outdoor although the infiltration efficiencies varied among homes. This study emphasizes the importance of relying on personal exposure in epidemiological studies assessing the impact of air pollution on human health.

  10. Indoor particle dynamics in a school office: determination of particle concentrations, deposition rates and penetration factors under naturally ventilated conditions.

    PubMed

    Cong, X C; Zhao, J J; Jing, Z; Wang, Q G; Ni, P F

    2018-05-09

    Recently, the problem of indoor particulate matter pollution has received much attention. An increasing number of epidemiological studies show that the concentration of atmospheric particulate matter has a significant effect on human health, even at very low concentrations. Most of these investigations have relied upon outdoor particle concentrations as surrogates of human exposures. However, considering that the concentration distribution of the indoor particulate matter is largely dependent on the extent to which these particles penetrate the building and on the degree of suspension in the indoor air, human exposures to particles of outdoor origin may not be equal to outdoor particle concentration levels. Therefore, it is critical to understand the relationship between the particle concentrations found outdoors and those found in indoor micro-environments. In this study, experiments were conducted using a naturally ventilated office located in Qingdao, China. The indoor and outdoor particle concentrations were measured at the same time using an optical counter with four size ranges. The particle size distribution ranged from 0.3 to 2.5 μm, and the experimental period was from April to September, 2016. Based on the experimental data, the dynamic and mass balance model based on time was used to estimate the penetration rate and deposition rate at air exchange rates of 0.03-0.25 h -1 . The values of the penetration rate and deposition velocity of indoor particles were determined to range from 0.45 to 0.82 h -1 and 1.71 to 2.82 m/h, respectively. In addition, the particulate pollution exposure in the indoor environment was analyzed to estimate the exposure hazard from indoor particulate matter pollution, which is important for human exposure to particles and associated health effects. The conclusions from this study can serve to provide a better understanding the dynamics and behaviors of airborne particle entering into buildings. And they will also highlight effective methods to reduce exposure to particles in office buildings.

  11. Passive Sampling for Indoor and Outdoor Exposures to Chlorpyrifos, Azinphos-Methyl, and Oxygen Analogs in a Rural Agricultural Community.

    PubMed

    Gibbs, Jenna L; Yost, Michael G; Negrete, Maria; Fenske, Richard A

    2017-03-01

    Recent studies have highlighted the increased potency of oxygen analogs of organophosphorus pesticides. These pesticides and oxygen analogs have previously been identified in the atmosphere following spray applications in the states of California and Washington. We used two passive sampling methods to measure levels of the ollowing organophosphorus pesticides: chlorpyrifos, azinphos-methyl, and their oxygen analogs at 14 farmworker and 9 non-farmworker households in an agricultural region of central Washington State in 2011. The passive methods included polyurethane foam passive air samplers deployed outdoors and indoors and polypropylene deposition plates deployed indoors. We collected cumulative monthly samples during the pesticide application seasons and during the winter season as a control. Monthly outdoor air concentrations ranged from 9.2 to 199 ng/m 3 for chlorpyrifos, 0.03 to 20 ng/m 3 for chlorpyrifos-oxon, < LOD (limit of detection) to 7.3 ng/m 3 for azinphos-methyl, and < LOD to 0.8 ng/m 3 for azinphos-methyl-oxon. Samples from proximal households (≤ 250 m) had significantly higher outdoor air concentrations of chlorpyrifos, chlorpyrifos-oxon, and azinphos-methyl than did samples from nonproximal households ( p ≤ 0.02). Overall, indoor air concentrations were lower than outdoors. For example, all outdoor air samples for chlorpyrifos and 97% of samples for azinphos-methyl were > LOD. Indoors, only 78% of air samples for chlorpyrifos and 35% of samples for azinphos-methyl were > LOD. Samples from farmworker households had higher indoor air concentrations of both pesticides than did samples from non-farmworker households. Mean indoor and outdoor air concentration ratios for chlorpyrifos and azinphos-methyl were 0.17 and 0.44, respectively. We identified higher levels in air and on surfaces at both proximal and farmworker households. Our findings further confirm the presence of pesticides and their oxygen analogs in air and highlight their potential for infiltration of indoor living environments. Citation: Gibbs JL, Yost MG, Negrete M, Fenske RA. 2017. Passive sampling for indoor and outdoor exposures to chlorpyrifos, azinphos-methyl, and oxygen analogs in a rural agricultural community. Environ Health Perspect 125:333-341; http://dx.doi.org/10.1289/EHP425.

  12. Risk Identification in a Smart Monitoring System Used to Preserve Artefacts Based on Textile Materials

    NASA Astrophysics Data System (ADS)

    Diaconescu, V. D.; Scripcariu, L.; Mătăsaru, P. D.; Diaconescu, M. R.; Ignat, C. A.

    2018-06-01

    Exhibited textile-materials-based artefacts can be affected by the environmental conditions. A smart monitoring system that commands an adaptive automatic environment control system is proposed for indoor exhibition spaces containing various textile artefacts. All exhibited objects are monitored by many multi-sensor nodes containing temperature, relative humidity and light sensors. Data collected periodically from the entire sensor network is stored in a database and statistically processed in order to identify and classify the environment risk. Risk consequences are analyzed depending on the risk class and the smart system commands different control measures in order to stabilize the indoor environment conditions to the recommended values and prevent material degradation.

  13. Indoor air in schools and lung function of Austrian school children.

    PubMed

    Wallner, Peter; Kundi, Michael; Moshammer, Hanns; Piegler, Kathrin; Hohenblum, Philipp; Scharf, Sigrid; Fröhlich, Marina; Damberger, Bernhard; Tappler, Peter; Hutter, Hans-Peter

    2012-07-01

    The Children's Environment and Health Action Plan for Europe (CEHAPE) of WHO focuses (inter alia) on improving indoor environments where children spend most of their time. At present, only little is known about air pollution in schools and its effect on the lung function of school children. Our project was set up as an Austrian contribution to CEHAPE. In a cross-sectional approach, differences in indoor pollution in nine elementary all-day schools were assessed and 34 of these pollutants were analyzed for a relationship with respiratory health determined by spirometry using a linear regression model. Overall 596 children (aged 6-10 years) were eligible for the study. Spirometry was performed in 433 children. Socio-economic status, area of living (urban/rural), and smoking at home were included in the model as potential confounders with school-related average concentration of air pollutants as the variable of primary interest. A negative association with flow volumes (MEF(75)) was found for formaldehyde in air samples, benzylbutylphthalate and the sum of polybrominated diphenylethers in school dust. FVC and FEV(1) were negatively associated with ethylbenzene and xylenes in air samples and tris(1,3-dichlor-2-propyl)-phosphate on particulates. Although, in general, the quality of school indoor air was not worse than that reported for homes, effects on the respiratory health of children cannot be excluded. A multi-faceted strategy to improve the school environment is needed.

  14. Flow-based ammonia gas analyzer with an open channel scrubber for indoor environments.

    PubMed

    Ohira, Shin-Ichi; Heima, Minako; Yamasaki, Takayuki; Tanaka, Toshinori; Koga, Tomoko; Toda, Kei

    2013-11-15

    A robust and fully automated indoor ammonia gas monitoring system with an open channel scrubber (OCS) was developed. The sample gas channel dimensions, hydrophilic surface treatment to produce a thin absorbing solution layer, and solution flow rate of the OCS were optimized to connect the OCS as in-line gas collector and avoid sample humidity effects. The OCS effluent containing absorbed ammonia in sample gas was injected into a derivatization solution flow. Derivatization was achieved with o-phthalaldehyde and sulfite in pH 11 buffer solution. The product, 1-sulfonateisoindole, is detected with a home-made fluorescence detector. The limit of detection of the analyzer based on three times the standard deviation of baseline noise was 0.9 ppbv. Sample gas could be analyzed 40 times per hour. Furthermore, relative humidity of up to 90% did not interfere considerably with the analyzer. Interference from amines was not observed. The developed gas analysis system was calibrated using a solution-based method. The system was used to analyze ammonia in an indoor environment along with an off-site method, traditional impinger gas collection followed by ion chromatographic analysis, for comparison. The results obtained using both methods agreed well. Therefore, the developed system can perform on-site monitoring of ammonia in indoor environments with improved time resolution compared with that of other methods. Crown Copyright © 2013 Published by Elsevier B.V. All rights reserved.

  15. Determination of tobacco smoking influence on volatile organic compounds constituent by indoor tobacco smoking simulation experiment

    NASA Astrophysics Data System (ADS)

    Xie, Juexin; Wang, Xingming; Sheng, Guoying; Bi, Xinhui; Fu, Jiamo

    Tobacco smoking simulation experiment was conducted in a test room under different conditions such as cigarette brands, smoking number, and post-smoke decay in forced ventilation or in closed indoor environments. Thirty-seven chemical species were targeted and monitored, including volatile organic compounds (VOCs) and environmental tobacco smoke (ETS) markers. The results indicate that benzene, d-limonene, styrene, m-ethyltoluene and 1,2,4/1,3,5-trimethylbenzene are correlated well with ETS markers, but toluene, xylene, and ethylbenzene are not evidently correlated with ETS markers because there are some potential indoor sources of these compounds. 2,5-dimethylfuran is considered to be a better ETS marker due to the relative stability in different cigarette brands and a good relationship with other ETS markers. The VOCs concentrations emitted by tobacco smoking were linearly associated with the number of cigarettes consumed, and different behaviors were observed in closed indoor environment, of which ETS markers, d-limonene, styrene, trimethylbenzene, etc. decayed fast, whereas benzene, toluene, xylene, ethylbenzene, etc. decayed slowly and even increased in primary periods of the decay; hence ETS exposure in closed environments is believed to be more dangerous. VOCs concentrations and the relative percentage constituent of ETS markers of different brand cigarettes emissions vary largely, but the relative percentage constituent of ETS markers for the same brand cigarette emissions is similar.

  16. Limiting the Temperatures in Naturally Ventilated Buildings in Warm Climates. Building Research Establishment Current Paper 7/74.

    ERIC Educational Resources Information Center

    Petherbridge, P.

    Formulas used in the calculation of cooling loads and indoor temperatures are employed to demonstrate the influence of various building parameters--such as thermal transmittance (U-value), solar absorptivity, and thermal storage--on the indoor thermal environment. The analysis leads to guidance on ways of limiting temperatures in naturally…

  17. Green Thumbs: A Kid's Activity Guide to Indoor and Outdoor Gardening.

    ERIC Educational Resources Information Center

    Carlson, Laurie

    This guide contains indoor and outdoor gardening activities for children. The activities teach children how plants live and grow; how the weather, temperature, and seasons affect all living things; how living things come out of seeds and soil; how the birds, earthworms, bees, and toads help in the garden; and how the whole environment works…

  18. Exploring the consequences of climate change for indoor air quality

    NASA Astrophysics Data System (ADS)

    Nazaroff, William W.

    2013-03-01

    Climate change will affect the concentrations of air pollutants in buildings. The resulting shifts in human exposure may influence public health. Changes can be anticipated because of altered outdoor pollution and also owing to changes in buildings effected in response to changing climate. Three classes of factors govern indoor pollutant levels in occupied spaces: (a) properties of pollutants; (b) building factors, such as the ventilation rate; and (c) occupant behavior. Diversity of indoor conditions influences the public health significance of climate change. Potentially vulnerable subpopulations include not only the young and the infirm but also those who lack resources to respond effectively to changing conditions. Indoor air pollutant levels reflect the sum of contributions from indoor sources and from outdoor pollutants that enter with ventilation air. Pollutant classes with important indoor sources include the byproducts of combustion, radon, and volatile and semivolatile organic compounds. Outdoor pollutants of special concern include particulate matter and ozone. To ensure good indoor air quality it is important first to avoid high indoor emission rates for all pollutants and second to ensure adequate ventilation. A third factor is the use of air filtration or air cleaning to achieve further improvements where warranted. Reprinted with permission from Climate Change, the Indoor Environment, and Health (2011) by the National Academy of Sciences, Courtesy of the National Academies Press, Washington, DC.

  19. [European community guidelines and standards in indoor air quality: what proposals for Italy].

    PubMed

    Settimo, Gaetano; D'Alessandro, Daniela

    2014-01-01

    Indoor air quality is an issue on which to focus because of the increasing number of exposed population and in view of the strong public feeling on this issue. This paper reports the rules of EU and several European countries about indoor air quality, focusing on the initiatives performed in Italy to respond to WHO recommendations. Several EU countries have introduced in their legislation rules relating to indoor air quality. At the moment, in Italy, a reference rule has not been issued. For this reason, up to date main informations concerning some guidelines or reference values in indoor air, to be used for a first comparison, are those obtained by the scientific literature, or by the guidelines issued by other European countries or, for analogy, by other standard values such as limit or reference values regarding outdoor air. Even the EU, while reaffirming the priority of energy efficiency measures, recommends healthier indoor environments and the development of a specific European strategy on the issue of indoor air quality. The National Study Group on indoor pollution of the Italian National Health Institute (ISS), is working for the development of shared technical and scientific documents, in order to provide greater uniformity of actions at national level, waiting for a legal framework for indoor air quality, in the light of the indication already produced by the WHO.

  20. Effects of Indoor Air Pollutants on Atopic Dermatitis

    PubMed Central

    Kim, JaKyoung; Kim, HyungJin; Lim, DaeHyun; Lee, Young-Kyu; Kim, Jeong Hee

    2016-01-01

    The increasing prevalence of atopic dermatitis (AD) is associated with variations in indoor environments. In Korea, many inner walls of homes are covered with wallpaper: such walls emit indoor air pollutants, including volatile organic compounds (VOCs) and formaldehyde. This randomized, double-blind study investigated the effects of wallpaper on indoor air quality and AD. Thirty-one children (aged three to eight years) with moderate AD were assigned to environmentally-friendly (EF) and polyvinyl chloride (PVC) wallpaper groups. Indoor air concentrations of VOCs, natural VOCs (NVOCs), formaldehyde, and total suspended bacteria were measured before and two (W2) and eight weeks (W8) after wallpapering. Scoring Atopic Dermatitis (SCORAD) evaluations and blood tests were performed during the same period. The EF wallpaper and PVC wallpaper groups showed similar trends in the changes in total VOCs (TVOC) and formaldehyde content in the indoor air. However, the EF wallpaper group showed more improvement on the SCORAD at W2 and W8 than the PVC wallpaper group. The SCORAD index was positively correlated with several indoor air pollutants. Further, the SCORAD index and NVOC % were negatively correlated. Improved SCORAD index and effects of wallpapering on indoor air quality improvements occurred within a short period of time in both groups. We believe that NVOCs in indoor air after EF wallpapering have a beneficial effect on health. PMID:27941696

  1. High calorie, low nutrient food/beverage intake and video gaming in children as potential signals for addictive behavior.

    PubMed

    Pentz, Mary Ann; Spruijt-Metz, Donna; Chou, Chih Ping; Riggs, Nathaniel R

    2011-12-01

    Little is known about the co-occurrence of health risk behaviors in childhood that may signal later addictive behavior. Using a survey, this study evaluated high calorie, low nutrient HCLN intake and video gaming behaviors in 964 fourth grade children over 18 months, with stress, sensation-seeking, inhibitory control, grades, perceived safety of environment, and demographic variables as predictors. SEM and growth curve analyses supported a co-occurrence model with some support for addiction specificity. Male gender, free/reduced lunch, low perceived safety and low inhibitory control independently predicted both gaming and HCLN intake. Ethnicity and low stress predicted HCLN. The findings raise questions about whether living in some impoverished neighborhoods may contribute to social isolation characterized by staying indoors, and HCLN intake and video gaming as compensatory behaviors. Future prevention programs could include skills training for inhibitory control, combined with changes in the built environment that increase safety, e.g., implementing Safe Routes to School Programs.

  2. High Calorie, Low Nutrient Food/Beverage Intake and Video Gaming in Children as Potential Signals for Addictive Behavior

    PubMed Central

    Pentz, Mary Ann; Spruijt-Metz, Donna; Chou, Chih Ping; Riggs, Nathaniel R.

    2011-01-01

    Little is known about the co-occurrence of health risk behaviors in childhood that may signal later addictive behavior. Using a survey, this study evaluated high calorie, low nutrient HCLN intake and video gaming behaviors in 964 fourth grade children over 18 months, with stress, sensation-seeking, inhibitory control, grades, perceived safety of environment, and demographic variables as predictors. SEM and growth curve analyses supported a co-occurrence model with some support for addiction specificity. Male gender, free/reduced lunch, low perceived safety and low inhibitory control independently predicted both gaming and HCLN intake. Ethnicity and low stress predicted HCLN. The findings raise questions about whether living in some impoverished neighborhoods may contribute to social isolation characterized by staying indoors, and HCLN intake and video gaming as compensatory behaviors. Future prevention programs could include skills training for inhibitory control, combined with changes in the built environment that increase safety, e.g., implementing Safe Routes to School Programs. PMID:22408581

  3. Intelligent navigation and accurate positioning of an assist robot in indoor environments

    NASA Astrophysics Data System (ADS)

    Hua, Bin; Rama, Endri; Capi, Genci; Jindai, Mitsuru; Tsuri, Yosuke

    2017-12-01

    Intact robot's navigation and accurate positioning in indoor environments are still challenging tasks. Especially in robot applications, assisting disabled and/or elderly people in museums/art gallery environments. In this paper, we present a human-like navigation method, where the neural networks control the wheelchair robot to reach the goal location safely, by imitating the supervisor's motions, and positioning in the intended location. In a museum similar environment, the mobile robot starts navigation from various positions, and uses a low-cost camera to track the target picture, and a laser range finder to make a safe navigation. Results show that the neural controller with the Conjugate Gradient Backpropagation training algorithm gives a robust response to guide the mobile robot accurately to the goal position.

  4. Investigation of microbial community isolated from indoor artworks and air environment: identification, biodegradative abilities, and DNA typing.

    PubMed

    Pangallo, Domenico; Chovanová, Katarina; Simonovicová, Alexandra; Ferianc, Peter

    2009-03-01

    This study deals with establishing the characteristics of a microbial community isolated from indoor artworks and the surrounding air environment. It is one of the few studies on microbial degradation of indoor artworks. It shows the potential biodegradative risk that can occur if artworks are not exhibited and conserved in an appropriate environment. The microbial community isolated from the indoor artworks and air environment was examined by cultural and molecular methods. Different plate assays were used to screen the biodegradative activity of the isolated microflora: Remazol Brilliant Blue R, phenol red, and Azure B for the ligninolytic properties; Ostazin brilliant red H-3B for cellulose degradation; CaCO3 glucose agar for solubilization activity; and B4 agar for biomineralization. To type the bacterial and fungal isolates, 2 PCR methods, repetitive extragenic palindromes (REP) and random amplified microsatellite polymorphisms (RAMP) were used. The art objects were principally colonized by fungi. The most commonly isolated strains were represented by hyphomycetes of the genera Penicillium, Aspergillus, Cladosporium, and Chaetomium. Members of these genera showed intensive biodegradation activity, both on wood and on stone. Bacteria were predominant in the air, exhibiting complex communities, both in the air and on the artworks. The most frequently isolated genera were Bacillus and Staphylococcus with extensive biodegradation abilities. REP-PCR revealed high variability within strains belonging to the same genus. RAMP is a new PCR-based method, used in this research for the first time to cluster the microfilamentous fungi and to characterize and select especially Penicillium and Aspergillus strains, which were isolated in a large number.

  5. [Impact on the indoor environment of allergic children of the medical counselor on indoor environment, after two successive visits at 6 months interval].

    PubMed

    Montaudié-Dumas, I; Giovannini-Chami, L; Debai, C; Collomp, R; Bailly-Piccini, C; Berlioz, M; Albertini, M; Bourrier, T

    2013-12-01

    The aim of this retrospective study was to assess the impact of a medical indoor environment counselor (MIEC) on the allergic child's indoor home environment, as well as the real-life experience of patients' families. We enrolled 50 children (age, 4-18 years) with allergic respiratory illness (96 % asthmatics) from March 2011 to January 2012. During the first visit, the CMEI gave advice according to the results of the assessment. Home environmental exposures were assessed 6 months later. A satisfaction questionnaire was completed by the parents. We found a significant decrease in the presence of house dust mites (P = 0.0047), humidity, and molds (P = 0.0047) as well as volatile organic compounds (P = 0.0047). Smoking habits were not significantly changed (P = 0.083), nor was the presence of domestic pets (P = 0.3173). Over 74 % of the families were very satisfied with the CMEI's intervention. According to de Blay's study, a home visit by the MEIC increased compliance with mite reduction. The intervention to advise parents of asthmatic children on the risks of passive smoking was ineffective in reducing their children's exposure to environmental tobacco smoke. The advice given by the MEIC was better understood by the patients than that expressed by the medical teams. A targeted home-based environmental intervention increased the compliance to mite, humidity, and mold reduction. The role of the CMEI will undoubtedly develop: follow-up studies are necessary to justify their activity (cost-efficacy ratio of their intervention).

  6. Strength of clean indoor air laws and smoking related outcomes in the USA

    PubMed Central

    McMullen, K; Brownson, R; Luke, D; Chriqui, J

    2005-01-01

    Objectives: Environmental tobacco smoke (ETS) is often encountered in the workplace. There have been efforts to apply and enforce state laws limiting workplace smoking. There has been little study of the relative effectiveness of state and/or local laws in affecting both rates of workplace ETS exposure and adult smoking rates. This study investigates these hypotheses, as well as the effect of these laws on youth smoking. Design: This is a secondary data analysis using sources including the Current Population Survey (CPS), Behavioral Risk Factor Surveillance System (BRFSS), Youth Risk Behavior Survey (YRBS), and the National Household Survey of Drug Abuse (NHSDA) between the years of 1996 and 1999. Linear regression models were used to investigate the effect of a state's clean indoor air (CIA) law (using a measure of extensiveness) on the overall amount of people who reported working in a smoke-free environment, youth smoking rates and adult smoking rates. Results: The extensiveness of a state's CIA law was found to be a reliable predictor of the percentage of indoor workers who report a smoke-free work environment and the rates of youth smoking. State CIA laws were not conclusively associated with adult smoking rates. Conclusions: The extensiveness of a state's CIA law is strongly associated with a higher percentage of indoor workers reporting a smoke-free work environment. This study did not reveal a similar association between local laws and smoke-free work environments. Youth smoking rates, shown to be related to state CIA laws, may be further affected with more stringent CIA policy. PMID:15735299

  7. Detection of airborne Stachybotrys chartarum macrocyclic trichothecene mycotoxins in the indoor environment.

    PubMed

    Brasel, T L; Martin, J M; Carriker, C G; Wilson, S C; Straus, D C

    2005-11-01

    The existence of airborne mycotoxins in mold-contaminated buildings has long been hypothesized to be a potential occupant health risk. However, little work has been done to demonstrate the presence of these compounds in such environments. The presence of airborne macrocyclic trichothecene mycotoxins in indoor environments with known Stachybotrys chartarum contamination was therefore investigated. In seven buildings, air was collected using a high-volume liquid impaction bioaerosol sampler (SpinCon PAS 450-10) under static or disturbed conditions. An additional building was sampled using an Andersen GPS-1 PUF sampler modified to separate and collect particulates smaller than conidia. Four control buildings (i.e., no detectable S. chartarum growth or history of water damage) and outdoor air were also tested. Samples were analyzed using a macrocyclic trichothecene-specific enzyme-linked immunosorbent assay (ELISA). ELISA specificity was tested using phosphate-buffered saline extracts of the fungal genera Aspergillus, Chaetomium, Cladosporium, Fusarium, Memnoniella, Penicillium, Rhizopus, and Trichoderma, five Stachybotrys strains, and the indoor air allergens Can f 1, Der p 1, and Fel d 1. For test buildings, the results showed that detectable toxin concentrations increased with the sampling time and short periods of air disturbance. Trichothecene values ranged from <10 to >1,300 pg/m3 of sampled air. The control environments demonstrated statistically significantly (P < 0.001) lower levels of airborne trichothecenes. ELISA specificity experiments demonstrated a high specificity for the trichothecene-producing strain of S. chartarum. Our data indicate that airborne macrocyclic trichothecenes can exist in Stachybotrys-contaminated buildings, and this should be taken into consideration in future indoor air quality investigations.

  8. A Smartphone Camera-Based Indoor Positioning Algorithm of Crowded Scenarios with the Assistance of Deep CNN.

    PubMed

    Jiao, Jichao; Li, Fei; Deng, Zhongliang; Ma, Wenjing

    2017-03-28

    Considering the installation cost and coverage, the received signal strength indicator (RSSI)-based indoor positioning system is widely used across the world. However, the indoor positioning performance, due to the interference of wireless signals that are caused by the complex indoor environment that includes a crowded population, cannot achieve the demands of indoor location-based services. In this paper, we focus on increasing the signal strength estimation accuracy considering the population density, which is different to the other RSSI-based indoor positioning methods. Therefore, we propose a new wireless signal compensation model considering the population density, distance, and frequency. First of all, the number of individuals in an indoor crowded scenario can be calculated by our convolutional neural network (CNN)-based human detection approach. Then, the relationship between the population density and the signal attenuation is described in our model. Finally, we use the trilateral positioning principle to realize the pedestrian location. According to the simulation and tests in the crowded scenarios, the proposed model increases the accuracy of the signal strength estimation by 1.53 times compared to that without considering the human body. Therefore, the localization accuracy is less than 1.37 m, which indicates that our algorithm can improve the indoor positioning performance and is superior to other RSSI models.

  9. An RFID Indoor Positioning Algorithm Based on Bayesian Probability and K-Nearest Neighbor.

    PubMed

    Xu, He; Ding, Ye; Li, Peng; Wang, Ruchuan; Li, Yizhu

    2017-08-05

    The Global Positioning System (GPS) is widely used in outdoor environmental positioning. However, GPS cannot support indoor positioning because there is no signal for positioning in an indoor environment. Nowadays, there are many situations which require indoor positioning, such as searching for a book in a library, looking for luggage in an airport, emergence navigation for fire alarms, robot location, etc. Many technologies, such as ultrasonic, sensors, Bluetooth, WiFi, magnetic field, Radio Frequency Identification (RFID), etc., are used to perform indoor positioning. Compared with other technologies, RFID used in indoor positioning is more cost and energy efficient. The Traditional RFID indoor positioning algorithm LANDMARC utilizes a Received Signal Strength (RSS) indicator to track objects. However, the RSS value is easily affected by environmental noise and other interference. In this paper, our purpose is to reduce the location fluctuation and error caused by multipath and environmental interference in LANDMARC. We propose a novel indoor positioning algorithm based on Bayesian probability and K -Nearest Neighbor (BKNN). The experimental results show that the Gaussian filter can filter some abnormal RSS values. The proposed BKNN algorithm has the smallest location error compared with the Gaussian-based algorithm, LANDMARC and an improved KNN algorithm. The average error in location estimation is about 15 cm using our method.

  10. External Exposure to Short- and Medium-Chain Chlorinated Paraffins for the General Population in Beijing, China.

    PubMed

    Gao, Wei; Cao, Dandan; Wang, Yingjun; Wu, Jing; Wang, Ying; Wang, Yawei; Jiang, Guibin

    2018-01-02

    Chlorinated paraffins (CPs) are a class of compounds that are currently produced and used in large amounts in commercial products worldwide. In this study, food, indoor air, indoor dust, and drinking water samples were collected to evaluate the external exposure levels of CPs and possible pathway for the general population in Beijing, China. Short chain CPs (SCCPs) and medium chain CPs (MCCPs) in 199 samples were analyzed using a gas chromatography tandem time-of-flight high-resolution mass spectrometry (GC-TOF-HR-MS) method. High levels of CPs were observed in the indoor environment from residential houses, offices, and student dormitories. The geometric mean concentrations (GM) of ∑SCCPs and ∑MCCPs in indoor dust were 92 μg g -1 and 82 μg g -1 , respectively, while in indoor air, the concentrations were 80 ng m -3 and 3.4 ng m -3 , respectively. The GM of ∑SCCPs and ∑MCCPs in the diet were 83 ng g -1 dry weight (dw) and 56 ng g -1 dw, respectively. The most important external exposure routes to CPs to the general populations in Beijing were food intake and indoor dust ingestion. Indoor dust and indoor air posed higher risks for toddlers and infants than for adults.

  11. Assessment of the Indoor Odour Impact in a Naturally Ventilated Room

    PubMed Central

    Eusebio, Lidia; Derudi, Marco; Capelli, Laura; Nano, Giuseppe; Sironi, Selena

    2017-01-01

    Indoor air quality influences people’s lives, potentially affecting their health and comfort. Nowadays, ventilation is the only technique commonly used for regulating indoor air quality. CO2 is the reference species considered in order to calculate the air exchange rates of indoor environments. Indeed, regarding air quality, the presence of pleasant or unpleasant odours can strongly influence the environmental comfort. In this paper, a case study of indoor air quality monitoring is reported. The indoor field tests were conducted measuring both CO2 concentration, using a photoacoustic multi-gas analyzer, and odour trends, using an electronic nose, in order to analyze and compare the information acquired. The indoor air monitoring campaign was run for a period of 20 working days into a university room. The work was focused on the determination of both CO2 and odour emission factors (OEF) emitted by the human activity and on the evaluation of the odour impact in a naturally ventilated room. The results highlighted that an air monitoring and recycling system based only on CO2 concentration and temperature measurements might be insufficient to ensure a good indoor air quality, whereas its performances could be improved by integrating the existing systems with an electronic nose for odour detection. PMID:28379190

  12. Robust and Accurate Image-Based Georeferencing Exploiting Relative Orientation Constraints

    NASA Astrophysics Data System (ADS)

    Cavegn, S.; Blaser, S.; Nebiker, S.; Haala, N.

    2018-05-01

    Urban environments with extended areas of poor GNSS coverage as well as indoor spaces that often rely on real-time SLAM algorithms for camera pose estimation require sophisticated georeferencing in order to fulfill our high requirements of a few centimeters for absolute 3D point measurement accuracies. Since we focus on image-based mobile mapping, we extended the structure-from-motion pipeline COLMAP with georeferencing capabilities by integrating exterior orientation parameters from direct sensor orientation or SLAM as well as ground control points into bundle adjustment. Furthermore, we exploit constraints for relative orientation parameters among all cameras in bundle adjustment, which leads to a significant robustness and accuracy increase especially by incorporating highly redundant multi-view image sequences. We evaluated our integrated georeferencing approach on two data sets, one captured outdoors by a vehicle-based multi-stereo mobile mapping system and the other captured indoors by a portable panoramic mobile mapping system. We obtained mean RMSE values for check point residuals between image-based georeferencing and tachymetry of 2 cm in an indoor area, and 3 cm in an urban environment where the measurement distances are a multiple compared to indoors. Moreover, in comparison to a solely image-based procedure, our integrated georeferencing approach showed a consistent accuracy increase by a factor of 2-3 at our outdoor test site. Due to pre-calibrated relative orientation parameters, images of all camera heads were oriented correctly in our challenging indoor environment. By performing self-calibration of relative orientation parameters among respective cameras of our vehicle-based mobile mapping system, remaining inaccuracies from suboptimal test field calibration were successfully compensated.

  13. Lipid biomarker analysis for the quantitative analysis of airborne microorganisms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Macnaughton, S.J.; Jenkins, T.L.; Cormier, M.R.

    1997-08-01

    There is an ever increasing concern regarding the presence of airborne microbial contaminants within indoor air environments. Exposure to such biocontaminants can give rise to large numbers of different health effects including infectious diseases, allergenic responses and respiratory problems, Biocontaminants typically round in indoor air environments include bacteria, fungi, algae, protozoa and dust mites. Mycotoxins, endotoxins, pollens and residues of organisms are also known to cause adverse health effects. A quantitative detection/identification technique independent of culturability that assays both culturable and non culturable biomass including endotoxin is critical in defining risks from indoor air biocontamination. Traditionally, methods employed for themore » monitoring of microorganism numbers in indoor air environments involve classical culture based techniques and/or direct microscopic counting. It has been repeatedly documented that viable microorganism counts only account for between 0.1-10% of the total community detectable by direct counting. The classic viable microbiologic approach doe`s not provide accurate estimates of microbial fragments or other indoor air components that can act as antigens and induce or potentiate allergic responses. Although bioaerosol samplers are designed to damage the microbes as little as possible, microbial stress has been shown to result from air sampling, aerosolization and microbial collection. Higher collection efficiency results in greater cell damage while less cell damage often results in lower collection efficiency. Filtration can collect particulates at almost 100% efficiency, but captured microorganisms may become dehydrated and damaged resulting in non-culturability, however, the lipid biomarker assays described herein do not rely on cell culture. Lipids are components that are universally distributed throughout cells providing a means to assess independent of culturability.« less

  14. Subclinical cytomegalovirus infection associates with altered host immunity, gut microbiota and vaccine responses.

    PubMed

    Santos Rocha, Clarissa; Hirao, Lauren A; Weber, Mariana G; Méndez-Lagares, Gema; Chang, W L William; Jiang, Guochun; Deere, Jesse D; Sparger, Ellen E; Roberts, Jeffrey; Barry, Peter A; Hartigan-O'Connor, Dennis J; Dandekar, Satya

    2018-04-18

    Subclinical viral infections (SVI) including cytomegalovirus (CMV) are highly prevalent in humans, resulting in life-long persistence. However, the impact of SVI on the interplay between the host immunity and gut microbiota in the context of environmental exposures is not well defined. We utilized the preclinical nonhuman primate (NHP) model consisting of SVI-free (SPF) rhesus macaques and compared them to the animals with SVI (non-SPF) acquired through natural exposure and investigated the impact of SVI on immune cell distribution and function as well as on gut microbiota. These changes were examined in animals housed in the outdoor environment as compared to the controlled indoor environment. We report that SVI are associated with altered immune cell subsets and gut microbiota composition in animals housed in the outdoor environment. Non-SPF animals harbored a higher proportion of potential butyrate-producing Firmicutes and higher numbers of lymphocytes, effector T cells and cytokine-producing T cells. Surprisingly, these differences diminished following their transfer to the controlled indoor environment, suggesting that non-SPFs had increased responsiveness to environmental exposures. An experimental infection of indoor SPF animals with CMV resulted in an increased abundance of butyrate-producing bacteria, validating that CMV enhanced colonization of butyrate-producing commensals. Finally, non-SPF animals displayed lower antibody responses to influenza vaccination as compared to SPF animals. Our data show that subclinical CMV infection heightens host immunity and gut microbiota changes in response to environmental exposures. This may contribute to the heterogeneity in host immune response to vaccines and environmental stimuli at the population level. IMPORTANCE Humans harbor several latent viruses that modulate host immunity and commensal microbiota, thus introducing heterogeneity in their responses to pathogens, vaccines and environmental exposures. Most of our understanding of the effect of CMV on the immune system is based on studies of children acquiring CMV or of immune-compromised humans with acute or reactivated CMV infection or in ageing individuals. The experimental mouse models are genetically inbred and are completely adapted to the indoor laboratory environment. In contrast, nonhuman primates are genetically outbred and are raised in the outdoor environment. Our study is the first to report the impact of long-term subclinical CMV infection on host immunity and gut microbiota, which is evident only in the outdoor environment but not in the indoor environment. The significance of this study is in highlighting the impact of SVI on enhancing host immune susceptibility to environmental exposures and immune heterogeneity. Copyright © 2018 American Society for Microbiology.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arundel, A.V.; Sterling, E.M.; Biggin, J.H.

    A review of the health effects of relative humidity in indoor environments suggests that relative humidity can affect the incidence of respiratory infections and allergies. Experimental studies on airborne-transmitted infectious bacteria and viruses have shown that the survival or infectivity of these organisms is minimized by exposure to relative humidities between 40 and 70%. Nine epidemiological studies examined the relationship between the number of respiratory infections or absenteeism and the relative humidity of the office, residence, or school. The incidence of absenteeism or respiratory infections was found to be lower among people working or living in environments with mid-range versusmore » low or high relative humidities. The indoor size of allergenic mite and fungal populations is directly dependent upon the relative humidity. Mite populations are minimized when the relative humidity is below 50% and reach a maximum size at 80% relative humidity. Most species of fungi cannot grow unless the relative humidity exceeds 60%. Relative humidity also affects the rate of offgassing of formaldehyde from indoor building materials, the rate of formation of acids and salts from sulfur and nitrogen dioxide, and the rate of formation of ozone. The influence of relative humidity on the abundance of allergens, pathogens, and noxious chemicals suggests that indoor relative humidity levels should be considered as a factor of indoor air quality. The majority of adverse health effects caused by relative humidity would be minimized by maintaining indoor levels between 40 and 60%. This would require humidification during winter in areas with cold winter climates. Humidification should preferably use evaporative or steam humidifiers, as cool mist humidifiers can disseminate aerosols contaminated with allergens.« less

  16. Brominated flame retardants (BFRs) in indoor and outdoor air in a community in Guangzhou, a megacity of southern China.

    PubMed

    Ding, Nan; Wang, Tao; Chen, She-Jun; Yu, Mei; Zhu, Zhi-Cheng; Tian, Mi; Luo, Xiao-Jun; Mai, Bi-Xian

    2016-05-01

    Indoor environments contribute a significant portion of human exposure to brominated flame retardants (BFRs) because of their extensive use in various household products. This study investigates the occurrence of a number of BFRs in the indoor and outdoor air in a megacity in southern China, in which little information on indoor BFRs contamination is available. The estimated total PBDE concentrations ranged from 1.43 to 57 pg/m(3) indoors and from 1.21 to 1522 pg/m(3) outdoors. The indoor concentrations of lower brominated PBDEs that are mainly derived from the technical penta- and octa-BDE mixtures were higher than or comparable to the outdoors, while the indoor levels of DecaBDEs and decabromodiphenyl ethane (DBDPE) were apparently lower than the outdoors. The seasonal variations of BFR concentrations indicated that evaporation from old indoor products is the primary source of Penta- and OctaBDEs in the air, whereas most DecaBDEs and DBDPE concentrations showing weak temperature-dependence are largely released from industrial activities. The PBDE congener profiles in the air were generally similar, which were dominated by BDE209, 28, and 47; whereas the appreciable indoor-outdoor differences in the compositions are possibly due to emission sources, photochemical degradation, or congener-specific transport of BFRs in the indoor and outdoor air. Significant correlations between the indoor and outdoor BFRs were observed suggesting the exchange of BFRs between the two compartments, which are more noticeable for PentaBDEs and DecaBDEs with strong indoor and outdoor emission sources, respectively. This study provides significant insights into the sources of BFRs in urban air in China. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Indoor air quality in Latino homes in Boulder, Colorado

    NASA Astrophysics Data System (ADS)

    Escobedo, Luis E.; Champion, Wyatt M.; Li, Ning; Montoya, Lupita D.

    2014-08-01

    Indoor concentrations of airborne pollutants can be several times higher than those found outdoors, often due to poor ventilation, overcrowding, and the contribution of indoor sources within a home. Americans spend most of their time indoors where exposure to poor indoor air quality (IAQ) can result in diminished respiratory and cardiovascular health. This study measured the indoor air quality in 30 homes of a low-income Latino community in Boulder, Colorado during the summer of 2012. Participants were administered a survey, which included questions on their health conditions and indoor air pollution sources like cigarette smoke, heating fuel, and building materials. Twenty-four hour samples of fine particulate matter (PM2.5) from the indoor air were collected in each home; ambient PM2.5 samples were collected each day as well. Concurrent air samples were collected onto 47 mm Teflo and Tissuquartz filter at each location. Teflo filters were analyzed gravimetrically to measure PM2.5 and their extracts were used to determine levels of proteins and endotoxins in the fine fraction. The Tissuquartz filters were analyzed for elemental and organic carbon content (EC/OC). Results indicated that the indoor air contained higher concentrations of PM2.5 than the ambient air, and that the levels of OC were much higher than EC in both indoor and outdoor samples. This community showed no smoking in their homes and kept furry pets indoors at very low rates; therefore, cooking is likely the primary source of indoor PM. For responders with significant exposure to PM, it appeared to be primarily from occupational environments or childhood exposure abroad. Our findings indicate that for immigrant communities such as this, it is important to consider not only their housing conditions but also the relevant prior exposures when conducting health assessments.

  18. School food environments associated with adiposity in Canadian children.

    PubMed

    Fitzpatrick, C; Datta, G D; Henderson, M; Gray-Donald, K; Kestens, Y; Barnett, T A

    2017-07-01

    Targeting obesogenic features of children's environment that are amenable to change represents a promising strategy for health promotion. The school food environment, defined as the services and policies regarding nutrition and the availability of food in the school and surrounding neighborhood, is particularly important given that students travel through the school neighborhood almost daily and that they consume a substantial proportion of their calories at school. As part of the Quebec Adipose and Lifestyle Investigation in Youth (QUALITY) cohort study, we assessed features of school indoor dietary environment and the surrounding school neighborhoods, when children were aged 8-10 years (2005-2008). School principals reported on food practices and policies within the schools. The density of convenience stores and fast-food outlets surrounding the school was computed using a Geographical Information System. Indicators of school neighborhood deprivation were derived from census data. Adiposity outcomes were measured in a clinical setting 2 years later, when participants were aged 10-12 years (2008-2011). We conducted cluster analyses to identify school food environment types. Associations between school types and adiposity were estimated in linear regression models. Cluster analysis identified three school types with distinct food environments. Schools were characterized as: overall healthful (45%); a healthful food environment in the surrounding neighborhood, but an unhealthful indoor food environment (22%); or overall unhealthful (33%). Less healthful schools were located in more deprived neighborhoods and were associated with greater child adiposity. Despite regulatory efforts to improve school food environments, there is substantial inequity in dietary environments across schools. Ensuring healthful indoor and outdoor food environments across schools should be included in comprehensive efforts to reduce obesity-related health disparities.

  19. Linking Public Health, Housing, and Indoor Environmental Policy: Successes and Challenges at Local and Federal Agencies in the United States

    PubMed Central

    Jacobs, David E.; Kelly, Tom; Sobolewski, John

    2007-01-01

    We describe the successes and challenges faced by federal and local government agencies in the United States as they have attempted in recent years to connect public and environmental health, housing, community development, and building design with environmental, housing, and building laws, codes, and policies. These policies can either contribute to or adversely affect human physical and mental health, with important implications for economic viability, research, policy development, and overall social stability and progress. Policy impediments include tension between housing affordability and health investment that causes inefficient cost-shifting, privacy issues, unclear statutory authority, and resulting gaps in responsibility for housing, indoor air, and the built environment. We contrast this with other environmental frameworks such as ambient air and water quality statutes where the concept of “shared commons” and the “polluter pays” is more robust. The U.S. experiences in childhood lead poisoning prevention, indoor air, and mold provide useful policy insights. Local programs can effectively build healthy homes capacity through local laws and housing codes. The experience of coordinating remediation for mold, asthma triggers, weatherization, and other healthy housing improvements in Cuyahoga County, Ohio, is highlighted. The U.S. experience shows that policymakers should adopt a prevention-oriented, comprehensive multi-disciplinary approach at all levels of government to prevent unhealthy buildings, houses, and communities. PMID:17589610

  20. Quantile regression and Bayesian cluster detection to identify radon prone areas.

    PubMed

    Sarra, Annalina; Fontanella, Lara; Valentini, Pasquale; Palermi, Sergio

    2016-11-01

    Albeit the dominant source of radon in indoor environments is the geology of the territory, many studies have demonstrated that indoor radon concentrations also depend on dwelling-specific characteristics. Following a stepwise analysis, in this study we propose a combined approach to delineate radon prone areas. We first investigate the impact of various building covariates on indoor radon concentrations. To achieve a more complete picture of this association, we exploit the flexible formulation of a Bayesian spatial quantile regression, which is also equipped with parameters that controls the spatial dependence across data. The quantitative knowledge of the influence of each significant building-specific factor on the measured radon levels is employed to predict the radon concentrations that would have been found if the sampled buildings had possessed standard characteristics. Those normalised radon measures should reflect the geogenic radon potential of the underlying ground, which is a quantity directly related to the geological environment. The second stage of the analysis is aimed at identifying radon prone areas, and to this end, we adopt a Bayesian model for spatial cluster detection using as reference unit the building with standard characteristics. The case study is based on a data set of more than 2000 indoor radon measures, available for the Abruzzo region (Central Italy) and collected by the Agency of Environmental Protection of Abruzzo, during several indoor radon monitoring surveys. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. The Watcombe housing study: the short-term effect of improving housing conditions on the indoor environment.

    PubMed

    Richardson, George; Barton, Andrew; Basham, Meryl; Foy, Chris; Eick, Susan Ann; Somerville, Margaret

    2006-05-15

    A three-year study (1999-2001) was initiated in the UK to assess the effect of improving housing conditions in 3-4 bedroom, single-family unit, social rented sector houses on the health of the occupants. The houses were randomised into two groups. Phase I houses received extensive upgrading including wet central heating, on demand ventilation, double-glazed doors, cavity wall and roof/loft insulation. An identical intervention for Phase II houses was delayed for one year. As part of this randomised waiting list study, discrete measurements were made of indoor environmental variables in each house, to assess the short-term effects of improving housing conditions on the indoor environment. Variables representative of indoor environmental conditions were measured in the living room, bedroom and outdoors in each of the three years of the study. In 2000, there was a significant difference between the changes from 1999 to 2000 between Phase I (upgraded) and II (not then upgraded) houses for bedroom temperatures (p=0.002). Changes in wall surface dampness and wall dampness in Phase I houses were also significantly different to the change in Phase II houses in 2000 (p=0.001), but by 2001 the Phase I houses had reverted to the same dampness levels they had before upgrading. The housing upgrades increased bedroom temperatures in all houses. Other indoor environmental variables were not affected.

  2. A novel experimental technology for testing efficacy of air purifiers on pollen reduction.

    PubMed

    Bergmann, Karl-Christian; Sehlinger, Torsten; Gildemeister, Julia; Zuberbier, Torsten

    2017-01-01

    Allergenic pollen exposure is mostly seen as an outdoor phenomenon but studies have shown an indoor exposure: different pollen species including birch and grass pollen in houses, schools, and shops are leading to long-lasting symptoms even after the pollen season because pollen settle on surfaces and re-enter the indoor air depending on ventilation. To reduce indoor pollen load, windows need to be closed and devices should be used: as pure wiping and cleaning of surfaces is mostly not sufficient, air cleaners may be helpful in reducing pollen counts in indoor environment. The efficacy of an air cleaner is usually described by the filtration rate of standard dust particle sizes which is not necessarily related to clinical efficacy. A novel study design was developed using the technical equipment of a new mobile exposure chamber to investigate participants with allergic rhinitis (individual observational, controlled, prospective, single arm study). The tested air cleaner reduced the grass pollen-induced (4000 grass pollen/m 3 over 90 min) nasal symptoms (total nasal symptom score) significantly from 6 and 4 points (1st and 2nd exposure in sham run) to less than 1 point when air cleaner was activated. The novel study protocol is suitable for testing efficacy of air cleaners and the tested air cleaner is effective in reducing clinical symptoms due to grass pollen in an indoor environment.

  3. Laser-Based Slam with Efficient Occupancy Likelihood Map Learning for Dynamic Indoor Scenes

    NASA Astrophysics Data System (ADS)

    Li, Li; Yao, Jian; Xie, Renping; Tu, Jinge; Feng, Chen

    2016-06-01

    Location-Based Services (LBS) have attracted growing attention in recent years, especially in indoor environments. The fundamental technique of LBS is the map building for unknown environments, this technique also named as simultaneous localization and mapping (SLAM) in robotic society. In this paper, we propose a novel approach for SLAMin dynamic indoor scenes based on a 2D laser scanner mounted on a mobile Unmanned Ground Vehicle (UGV) with the help of the grid-based occupancy likelihood map. Instead of applying scan matching in two adjacent scans, we propose to match current scan with the occupancy likelihood map learned from all previous scans in multiple scales to avoid the accumulation of matching errors. Due to that the acquisition of the points in a scan is sequential but not simultaneous, there unavoidably exists the scan distortion at different extents. To compensate the scan distortion caused by the motion of the UGV, we propose to integrate a velocity of a laser range finder (LRF) into the scan matching optimization framework. Besides, to reduce the effect of dynamic objects such as walking pedestrians often existed in indoor scenes as much as possible, we propose a new occupancy likelihood map learning strategy by increasing or decreasing the probability of each occupancy grid after each scan matching. Experimental results in several challenged indoor scenes demonstrate that our proposed approach is capable of providing high-precision SLAM results.

  4. Outdoor and indoor aerosol size, number, mass and compositional dynamics at an urban background site during warm season

    NASA Astrophysics Data System (ADS)

    Talbot, N.; Kubelova, L.; Makes, O.; Cusack, M.; Ondracek, J.; Vodička, P.; Schwarz, J.; Zdimal, V.

    2016-04-01

    This paper describes the use of a unique valve switching system that allowed for high temporal resolution indoor and outdoor data to be collected concurrently from online C-ToF-AMS, SMPS and OC/EC, and offline BLPI measurements. The results reveal near real-time dynamic aerosol behaviour along a migration path from an outdoor to indoor environment. An outdoor reduction in NR-PM1 mass concentration occurred daily from AM (06:00-12:00) to PM (12:00-18:00). SO4 (26%-37%) [AM/PM] increased proportionally during afternoons at the expense of NO3 (18%-7%). The influences of mixing height, temperature and solar radiation were considered against the mean mass concentration loss for each species. Losses were then calculated according to species via a basic input/output model. NO3 lost the most mass during afternoon periods, which we attribute to the accelerated dissociation of NH4NO3 through increasing temperature and decreasing relative humidity. Indoor/outdoor (I/O) ratios varied from 0.46 for <40 nm to 0.65 for >100 nm. These ratios were calculated using average SMPS PNC measurements over the full campaign and corroborated using a novel technique of calculating I/O penetration ratios through the indoor migration of particles during a new particle formation event. This ratio was then used to observe changes in indoor composition relative to those outdoors. Indoor sampling was carried out in an undisturbed room with no known sources. Indoor concentrations were found to be proportional to those outdoors, with organic matter [2.7 μg/m3] and SO4 [1.7 μg/m3] being the most prominent species. These results are indicative of fairly rapid aerosol penetration, a source-free indoor environment and small afternoon I/O temperature gradients. Fine fraction NO3 was observed indoors in both real-time AMS PM1 and off-line BLPI measurements. Greater mass concentration losses were observed from filter measurements, highlighting an important time dependency factor when investigating semi-volatiles. Coarse mode NO3 was observed by impactor measurements, ascribing value to observing the full particle mass size distribution for understanding aerosol origin.

  5. An indoor navigation system for the visually impaired.

    PubMed

    Guerrero, Luis A; Vasquez, Francisco; Ochoa, Sergio F

    2012-01-01

    Navigation in indoor environments is highly challenging for the severely visually impaired, particularly in spaces visited for the first time. Several solutions have been proposed to deal with this challenge. Although some of them have shown to be useful in real scenarios, they involve an important deployment effort or use artifacts that are not natural for blind users. This paper presents an indoor navigation system that was designed taking into consideration usability as the quality requirement to be maximized. This solution enables one to identify the position of a person and calculates the velocity and direction of his movements. Using this information, the system determines the user's trajectory, locates possible obstacles in that route, and offers navigation information to the user. The solution has been evaluated using two experimental scenarios. Although the results are still not enough to provide strong conclusions, they indicate that the system is suitable to guide visually impaired people through an unknown built environment.

  6. Mercury persistence in indoor environments in the Amazon region, Brazil.

    PubMed

    Bastos, Wanderley Rodrigues; Fonseca, Márlon de Freitas; Pinto, Fernando Neves; Rebelo, Mauro de Freitas; dos Santos, Sérgio Silva; da Silveira, Ene Glória; Torres, João Paulo Machado; Malm, Olaf; Pfeiffer, Wolfgang Christian

    2004-10-01

    We evaluated the indoor atmospheric Hg contamination in gold trade shops in two Brazilian cities of the Legal Amazon area using the Spanish moss (Tillandsia usneoides, Bromeliaceae) as a sentinel species. Plants inside plastic cages were exposed to a controlled atmosphere to evaluate the rate of Hg retention over time and then distributed in several stores with different characteristics to enable a relative comparison. Hg concentrations were determined by cold vapor atomic absorption spectrophotometry. Plants exposed in active stores with good air circulation exhibited lower levels. Ex-gold trade shops that were kept closed for long periods exhibited higher values. Stores that have been restored before being transformed into new businesses exhibited lower values than nonrestored ones. Direct measurements suggest that indoor Hg air concentrations were below the threshold limit recommended by the World Health Organization to occupational exposure; nevertheless, restoring ex-gold trade shops could ensure a healthier working environment.

  7. Emissions of air pollutants from scented candles burning in a test chamber

    NASA Astrophysics Data System (ADS)

    Derudi, Marco; Gelosa, Simone; Sliepcevich, Andrea; Cattaneo, Andrea; Rota, Renato; Cavallo, Domenico; Nano, Giuseppe

    2012-08-01

    Burning of scented candles in indoor environment can release a large number of toxic chemicals. However, in spite of the large market penetration of scented candles, very few works investigated their organic pollutants emissions. This paper investigates volatile organic compounds emissions, with particular reference to the priority indoor pollutants identified by the European Commission, from the burning of scented candles in a laboratory-scale test chamber. It has been found that BTEX and PAHs emission factors show large differences among different candles, possibly due to the raw paraffinic material used, while aldehydes emission factors seem more related to the presence of additives. This clearly evidences the need for simple and cheap methodologies to measure the emission factors of commercial candles in order to foresee the expected pollutant concentration in a given indoor environment and compare it with health safety standards.

  8. Propagation Characteristics of International Space Station Wireless Local Area Network

    NASA Technical Reports Server (NTRS)

    Sham, Catherine C.; Hwn, Shian U.; Loh, Yin-Chung

    2005-01-01

    This paper describes the application of the Uniform Geometrical Theory of Diffraction (UTD) for Space Station Wireless Local Area Networks (WLANs) indoor propagation characteristics analysis. The verification results indicate good correlation between UTD computed and measured signal strength. It is observed that the propagation characteristics are quite different in the Space Station modules as compared with those in the typical indoor WLANs environment, such as an office building. The existing indoor propagation models are not readily applicable to the Space Station module environment. The Space Station modules can be regarded as oversized imperfect waveguides. Two distinct propagation regions separated by a breakpoint exist. The propagation exhibits the guided wave characteristics. The propagation loss in the Space Station, thus, is much smaller than that in the typical office building. The path loss model developed in this paper is applicable for Space Station WLAN RF coverage and link performance analysis.

  9. About the Subdivision of Indoor Spaces in Indoorgml

    NASA Astrophysics Data System (ADS)

    Diakité, A. A.; Zlatanova, S.; Li, K.-J.

    2017-10-01

    Boosted by the dynamic urbanization of cities, indoor environments are getting more and more complex in order to be able to host people properly. While most of our time is spent inside buildings, the need of GIS tools to assist our daily activities that can become tedious, such as indoor navigation or facility management, became more and more urgent. In that perspective, the IndoorGML standard is aiming to address the gaps left by other standards regarding the spatial modelling for indoor navigation. It includes several concepts such as the organization of the spaces into cells along with their network representation and the possibility to represent multiple connected layers. However, being at its first stage, several concepts of the standard could be improved. One of these is the cell subspacing that is not enough discussed in the current version of the standard. In this paper, we explore all the aspects involved in the subdivision process, from the identification of the navigable and non-navigable space cells to the generation of a navigation graph. We propose several criteria on which the indoor sub-spacing can rely to be automatically performed and and illustrate them on a 3D indoor model.

  10. Carbonyl levels in indoor and outdoor air in Mexico City and Xalapa, Mexico.

    PubMed

    Báez, Armando; Padilla, Hugo; García, Rocío; Torres, Ma del Carmen; Rosas, Irma; Belmont, Raúl

    2003-01-20

    Carbonyl compounds in air were measured at two houses, three museums, and two offices. All sites lacked air-conditioning systems. Although indoor and outdoor air was measured simultaneously at each site, the sites themselves were sampled in different dates. Mean concentrations were higher in indoor air. Outdoor means concentrations of acetone were the highest in all sites, ranging from 12 to 60 microg m(-3). In general, formaldehyde and acetaldehyde had similar mean concentrations, ranging from 4 to 32 and 6 to 28 microg m(-3), respectively. Formaldehyde and acetone mean indoor concentrations were the highest, ranging from 11 to 97 and 17 to 89 microg m(-3), respectively, followed by acetaldehyde with 5 to 47 microg m(-3). Formaldehyde and acetaldehyde had the highest mean concentration in the offices where there were smokers. Propionaldehyde and butyraldehyde concentrations did not show definite differences between indoor and outdoor air. In general, the highest outdoor and indoor hourly concentrations were observed from 10:00 to 15:00 h. Mean indoor/outdoor ratios of carbonyls exceeded 1. Formaldehyde and acetaldehyde risks were higher in smoking environments. Copyright 2002 Elsevier Science B.V.

  11. [Effect of large-scale repair work on indoor formaldehyde levels upon and subjective symptoms in, medical students during gross anatomy dissection course].

    PubMed

    Mori, Mihoko; Hoshiko, Michiko; Hara, Kunio; Ishitake, Tatsuya; Saga, Tsuyoshi; Yamaki, Koichi

    2012-01-01

    To examine the effect of large-scale repair work on indoor formaldehyde (FA) levels and subjective symptoms in medical students during a gross anatomy dissection course. We measured the indoor FA levels, room air temperature, and room humidity during a gross anatomy dissection course. In addition, the prevalence of subjective symptoms, keeping allergy state, and wearing personal protective equipment were surveyed in two groups of students using a self-administered questionnaire. The mean indoor FA levels before and after repair work were 1.22 ppm and 0.14 ppm, respectively. The mean indoor FA level significantly decreased after repair work. The prevalences of most subjective symptoms before the anatomy practice were similar before and after the repair work. However, the prevalences of most subjective symptoms during the anatomy practice were lower after the repair work. The mean indoor FA levels and prevalences of subjective symptoms decreased after the repair work. We have to continuously monitor indoor FA levels, carry out private countermeasures to minimize exposure to FA, and maintain equipment for ventilation to be able to conduct practice in a comfortable environment.

  12. A cognitive robotic system based on the Soar cognitive architecture for mobile robot navigation, search, and mapping missions

    NASA Astrophysics Data System (ADS)

    Hanford, Scott D.

    Most unmanned vehicles used for civilian and military applications are remotely operated or are designed for specific applications. As these vehicles are used to perform more difficult missions or a larger number of missions in remote environments, there will be a great need for these vehicles to behave intelligently and autonomously. Cognitive architectures, computer programs that define mechanisms that are important for modeling and generating domain-independent intelligent behavior, have the potential for generating intelligent and autonomous behavior in unmanned vehicles. The research described in this presentation explored the use of the Soar cognitive architecture for cognitive robotics. The Cognitive Robotic System (CRS) has been developed to integrate software systems for motor control and sensor processing with Soar for unmanned vehicle control. The CRS has been tested using two mobile robot missions: outdoor navigation and search in an indoor environment. The use of the CRS for the outdoor navigation mission demonstrated that a Soar agent could autonomously navigate to a specified location while avoiding obstacles, including cul-de-sacs, with only a minimal amount of knowledge about the environment. While most systems use information from maps or long-range perceptual capabilities to avoid cul-de-sacs, a Soar agent in the CRS was able to recognize when a simple approach to avoiding obstacles was unsuccessful and switch to a different strategy for avoiding complex obstacles. During the indoor search mission, the CRS autonomously and intelligently searches a building for an object of interest and common intersection types. While searching the building, the Soar agent builds a topological map of the environment using information about the intersections the CRS detects. The agent uses this topological model (along with Soar's reasoning, planning, and learning mechanisms) to make intelligent decisions about how to effectively search the building. Once the object of interest has been detected, the Soar agent uses the topological map to make decisions about how to efficiently return to the location where the mission began. Additionally, the CRS can send an email containing step-by-step directions using the intersections in the environment as landmarks that describe a direct path from the mission's start location to the object of interest. The CRS has displayed several characteristics of intelligent behavior, including reasoning, planning, learning, and communication of learned knowledge, while autonomously performing two missions. The CRS has also demonstrated how Soar can be integrated with common robotic motor and perceptual systems that complement the strengths of Soar for unmanned vehicles and is one of the few systems that use perceptual systems such as occupancy grid, computer vision, and fuzzy logic algorithms with cognitive architectures for robotics. The use of these perceptual systems to generate symbolic information about the environment during the indoor search mission allowed the CRS to use Soar's planning and learning mechanisms, which have rarely been used by agents to control mobile robots in real environments. Additionally, the system developed for the indoor search mission represents the first known use of a topological map with a cognitive architecture on a mobile robot. The ability to learn both a topological map and production rules allowed the Soar agent used during the indoor search mission to make intelligent decisions and behave more efficiently as it learned about its environment. While the CRS has been applied to two different missions, it has been developed with the intention that it be extended in the future so it can be used as a general system for mobile robot control. The CRS can be expanded through the addition of new sensors and sensor processing algorithms, development of Soar agents with more production rules, and the use of new architectural mechanisms in Soar.

  13. Undisturbed dust as a metric of long-term indoor insecticide exposure: Residential DDT contamination from indoor residual spraying and its association with serum levels in the VHEMBE cohort.

    PubMed

    Gaspar, Fraser W; Chevrier, Jonathan; Bornman, Riana; Crause, Madelein; Obida, Muvhulawa; Barr, Dana Boyd; Bradman, Asa; Bouwman, Henk; Eskenazi, Brenda

    2015-12-01

    Although approximately 123 million people may be exposed to high levels of insecticides through the use of indoor residual spraying (IRS) for malaria control, few studies exist on indoor insecticide contamination due to IRS and its relationship with human exposure. In the present study, we developed a sampling method to collect undisturbed dust from 50 homes in Limpopo, South Africa, a region where dichlorodiphenyltrichloroethane (DDT) has been used in IRS programs to prevent malaria for ~70years. We quantified DDT and its degradation products, dichlorodiphenyldichloroethylene (DDE), and dichlorodiphenyldichloroethane (DDD) in dust samples to determine dust loading levels and compared these levels to paired serum concentrations of p,p'-DDT and p,p'-DDE in women residents. p,p'-DDT and p,p'-DDE had the highest detection frequencies in both dust (58% and 34% detection, respectively) and serum samples (98% and 100% detection, respectively). Significantly higher detection frequencies for o,p'-DDT, p,p'-DDE, and p,p'-DDD were observed in dust samples collected in buildings that had been previously sprayed for malaria control. We also observed a significant, positive association between dust loading and serum concentrations of p,p'-DDT and p,p'-DDE (Spearman's rho=0.68 and 0.54, respectively). Despite the low detection frequency in dust, our results indicate that undisturbed dust may be a good metric to quantify long-term home exposure to DDT-related compounds and that contamination of the home environment may be an important determinant/source of DDT and DDE exposure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Physical and Emotional Benefits of Different Exercise Environments Designed for Treadmill Running

    PubMed Central

    Churchill, Sarah M.; Brymer, Eric; Davids, Keith

    2017-01-01

    (1) Background: Green physical activity promotes physical health and mental wellbeing and interesting questions concern effects of this information on designing indoor exercise environments. This study examined the physical and emotional effects of different nature-based environments designed for indoor treadmill running; (2) Methods: In a counterbalanced experimental design, 30 participants performed three, twenty-minute treadmill runs at a self-selected pace while viewing either a static nature image, a dynamic nature image or self-selected entertainment. Distance ran, heart rate (HR) and five pre-and post-exercise emotional states were measured; (3) Results: Participants ran farther, and with higher HRs, with self-selected entertainment compared to the two nature-based environment designs. Participants attained lowered anger, dejection, anxiety and increased excitement post exercise in all of the designed environments. Happiness increased during the two nature-based environment designs compared with self-selected entertainment; (4) Conclusions: Self-selected entertainment encouraged greater physical performances whereas running in nature-based exercise environments elicited greater happiness immediately after running. PMID:28696384

  15. Physical and Emotional Benefits of Different Exercise Environments Designed for Treadmill Running.

    PubMed

    Yeh, Hsiao-Pu; Stone, Joseph A; Churchill, Sarah M; Brymer, Eric; Davids, Keith

    2017-07-11

    (1) Background: Green physical activity promotes physical health and mental wellbeing and interesting questions concern effects of this information on designing indoor exercise environments. This study examined the physical and emotional effects of different nature-based environments designed for indoor treadmill running; (2) Methods: In a counterbalanced experimental design, 30 participants performed three, twenty-minute treadmill runs at a self-selected pace while viewing either a static nature image, a dynamic nature image or self-selected entertainment. Distance ran, heart rate (HR) and five pre-and post-exercise emotional states were measured; (3) Results: Participants ran farther, and with higher HRs, with self-selected entertainment compared to the two nature-based environment designs. Participants attained lowered anger, dejection, anxiety and increased excitement post exercise in all of the designed environments. Happiness increased during the two nature-based environment designs compared with self-selected entertainment; (4) Conclusions: Self-selected entertainment encouraged greater physical performances whereas running in nature-based exercise environments elicited greater happiness immediately after running.

  16. Free-living amoebae: Health concerns in the indoor environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyndall, R.L.; Ironside, K.S.

    1990-01-01

    Free-living amoebae are the most likely protozoa implicated in health concerns of the indoor environment. These amoebae can be the source of allergic reactions, eye infections or, on rare occasions, encephalitis. While too large to be effectively aerosolized, free- living amoebae can support the multiplication of pathogens such as Legionella which are easily aerosolized and infectious via the pulmonary route. Traditional detection methods for free-living amoebae are laborious and time consuming. Newer techniques for rapidly detecting and quantitating free-living amoebae such as monoclonal antibodies, flow cytometry, gene probes, and laser optics have or could be employed. 25 refs.

  17. Experimental Measurements of the Water Evaporation Rate of a Physical Model

    NASA Astrophysics Data System (ADS)

    Turza, Róbert; Füri, Belo B.

    2017-03-01

    As the number of indoor swimming pools and wellness centers are currently growing, it is necessary to concentrate on the parameters of indoor environments. These parameters are necessary for the design of the HVAC systems that operate these premises. In indoor swimming-pool facilities, the energy demand is large due to ventilation losses from exhaust air. Since water evaporates from a pool's surface, exhaust air has a high water content and specific enthalpy. In this paper the results of the water evaporation rate measured from swimming pool surfaces at higher thermal water temperatures are described.

  18. A kind of improved fingerprinting indoor location method based on WiFi

    NASA Astrophysics Data System (ADS)

    Zeng, Xi; Lin, Wei

    2017-08-01

    In the prior inventions, because of the complexity of the indoor environment, it is hard to guarantee position precision. In this paper provides an improved method that can be adopted to increase the indoor positioning accuracy of handheld positioning device. This method will be the direction of the handheld device position Angle and number of access points two characteristics to join the fingerprint. The two parameters make our normal fingerprint database more abundant. The positioning test results from comparing the normal fingerprint database with the improved fingerprint database prove the later positioning more accurate.

  19. Reducing Indoor Noise Levels Using People's Perception on Greenery

    NASA Astrophysics Data System (ADS)

    Mediastika, Christina E.; Binarti, Floriberta

    2013-12-01

    Employees working in cubicles of open-plan offices in Indonesia were studied in regard to their perception on the ability of indoor greenery to reduce noise levels. Sansevieria trifasciata and Scindapsus sp were used. Each was placed in the cubicle and noise levels were measured without plants, with Sansevieria, and with Scindapsus in place. The meters showed very insignificant difference. However, responses to surveys indicated a perception of lower noise in the presence of greenery. This seemed to be supported by prior knowledge and preconception and may be useful in creating a "quieter" indoor environment.

  20. The status of indoor air pollution.

    PubMed Central

    Esmen, N A

    1985-01-01

    Indoor air pollution, specifically restricted in its meaning to chemicals in home indoor air environment, presents a new and probably an important challenge to the researchers of the air pollution field. The general overview of this topic suggests that the voluminous data generated in the past ten or so years have only defined the rudiments of the problem, and significant areas of research still exist. Among the important areas where information is lacking, the exposures to contaminants generated by the use of consumer products and through hobbies and crafts represent perhaps the most urgent need for substantial research. PMID:4085429

Top