  1. Indoor and Outdoor Surface-Growing Fungi Contamination at Higher Institutional Buildings in a Malaysian University

    NASA Astrophysics Data System (ADS)

    Er, C. M.; Sunar, N. M.; Leman, A. M.; Khalid, A.; Ali, R.; Zaidi, E.; Azhar, A. T. S.

    2018-04-01

    Surface-growing indoor and outdoor fungi were assessed using swabbing method to investigate the indoor contamination. The painted wall surface samples were collected from two institutional buildings (B1 and B2) of a university in southern Peninsular Malaysia; indoors and outdoors. The mould concentrations varied widely between indoor and outdoor surface samples of both buildings. The total indoor surface-growing mould concentration (8776.49 CFU/cm2) is significantly higher (p<0.05) than the total concentration of outdoor surface growing mould (209.91 CFU/cm2). Respectively, the mean concentration of indoor surface-growing mould (18920.13 CFU/cm2 for B1 and 3704.67 CFU/cm2 for B2) is significantly higher than their outdoor counterparts (99.95 CFU/cm2 for b1 and for 319.86 CFU/cm2 b2) at these buildings. Besides, various air quality parameters (relative humidity, temperature and air velocity) were also measured indoors and outdoors during the study and violation of the guideline provided by ICOP-IAQ 2010 were proven in indoor environment in both buildings. The results of this assessment showed that the indoor environments of both institutional buildings were contaminated by the surface-growing mould. It also suggested the faulty designs and/or usages of building material in these institutional buildings contributed toward the contamination. An innovative solution is needed to correct the problems.

  2. Air- and Dustborne Mycoflora in Houses Free of Water Damage and Fungal Growth

    PubMed Central

    Horner, W. Elliott; Worthan, Anthony G.; Morey, Philip R.

    2004-01-01

    Typically, studies on indoor fungal growth in buildings focus on structures with known or suspected water damage, moisture, and/or indoor fungal growth problems. Reference information on types of culturable fungi and total fungal levels are generally not available for buildings without these problems. This study assessed 50 detached single-family homes in metropolitan Atlanta, Ga., to establish a baseline of “normal and typical” types and concentrations of airborne and dustborne fungi in urban homes which were predetermined not to have noteworthy moisture problems or indoor fungal growth. Each home was visually examined, and samples of indoor and outdoor air and of indoor settled dust were taken in winter and summer. The results showed that rankings by prevalence and abundance of the types of airborne and dustborne fungi did not differ from winter to summer, nor did these rankings differ when air samples taken indoors were compared with those taken outdoors. Water indicator fungi were essentially absent from both air and dust samples. The air and dust data sets were also examined specifically for the proportions of colonies from ecological groupings such as leaf surface fungi and soil fungi. In the analysis of dust for culturable fungal colonies, leaf surface fungi constituted a considerable portion (>20%) of the total colonies in at least 85% of the samples. Thus, replicate dust samples with less than 20% of colonies from leaf surface fungi are unlikely to be from buildings free of moisture or mold growth problems. PMID:15528497

  3. The diversity and distribution of fungi on residential surfaces.

    PubMed

    Adams, Rachel I; Miletto, Marzia; Taylor, John W; Bruns, Thomas D

    2013-01-01

    The predominant hypothesis regarding the composition of microbial assemblages in indoor environments is that fungal assemblages are structured by outdoor air with a moderate contribution by surface growth, whereas indoor bacterial assemblages represent a mixture of bacteria entered from outdoor air, shed by building inhabitants, and grown on surfaces. To test the fungal aspect of this hypothesis, we sampled fungi from three surface types likely to support growth and therefore possible contributors of fungi to indoor air: drains in kitchens and bathrooms, sills beneath condensation-prone windows, and skin of human inhabitants. Sampling was done in replicated units of a university-housing complex without reported mold problems, and sequences were analyzed using both QIIME and the new UPARSE approach to OTU-binning, to the same result. Surfaces demonstrated a mycological profile similar to that of outdoor air from the same locality, and assemblages clustered by surface type. "Weedy" genera typical of indoor air, such as Cladosporium and Cryptococcus, were abundant on sills, as were a diverse set of fungi of likely outdoor origin. Drains supported more depauperate assemblages than the other surfaces and contained thermotolerant genera such as Exophiala, Candida, and Fusarium. Most surprising was the composition detected on residents' foreheads. In addition to harboring Malassezia, a known human commensal, skin also possessed a surprising richness of non-resident fungi, including plant pathogens such as ergot (Claviceps purperea). Overall, fungal richness across indoor surfaces was high, but based on known autecologies, most of these fungi were unlikely to be growing on surfaces. We conclude that while some endogenous fungal growth on typical household surfaces does occur, particularly on drains and skin, all residential surfaces appear - to varying degrees - to be passive collectors of airborne fungi of putative outdoor origin, a view of the origins of the indoor microbiome quite different from bacteria.

  4. Fungal microcolonies on indoor surfaces — an explanation for the base-level fungal spore counts in indoor air

    NASA Astrophysics Data System (ADS)

    Pasanen, A.-L.; Heinonen-Tanski, H.; Kalliokoski, P.; Jantunen, M. J.

    In the subarctic winter, fungal spores are found in indoor air even when outdoor spore levels are very low. The results of this study support an explanation that some indoor airborne fungal spores are derived from unnoticeable fungal microcolonies, which may develop on temporarily wet surfaces. Laboratory experiments on Penicillium verrucosum indicated that the fungus germinated on new wallpaper very quickly (about half an hour) under moist conditions. Hyphal growth and sporulation of the fungus on moist wallpaper occured within one day of incubation. In gravity-settling tape samples from occasionally wet surfaces in a suburban home, large spore aggregates, hyphal fragments with some spores and spores in the germination stage were found, indicating fungal growth. These experiments showed that fungal microcolonies can develop within a week on occasionally wet indoor surfaces.

  5. The Diversity and Distribution of Fungi on Residential Surfaces

    PubMed Central

    Adams, Rachel I.; Miletto, Marzia; Taylor, John W.; Bruns, Thomas D.

    2013-01-01

    The predominant hypothesis regarding the composition of microbial assemblages in indoor environments is that fungal assemblages are structured by outdoor air with a moderate contribution by surface growth, whereas indoor bacterial assemblages represent a mixture of bacteria entered from outdoor air, shed by building inhabitants, and grown on surfaces. To test the fungal aspect of this hypothesis, we sampled fungi from three surface types likely to support growth and therefore possible contributors of fungi to indoor air: drains in kitchens and bathrooms, sills beneath condensation-prone windows, and skin of human inhabitants. Sampling was done in replicated units of a university-housing complex without reported mold problems, and sequences were analyzed using both QIIME and the new UPARSE approach to OTU-binning, to the same result. Surfaces demonstrated a mycological profile similar to that of outdoor air from the same locality, and assemblages clustered by surface type. “Weedy” genera typical of indoor air, such as Cladosporium and Cryptococcus, were abundant on sills, as were a diverse set of fungi of likely outdoor origin. Drains supported more depauperate assemblages than the other surfaces and contained thermotolerant genera such as Exophiala, Candida, and Fusarium. Most surprising was the composition detected on residents’ foreheads. In addition to harboring Malassezia, a known human commensal, skin also possessed a surprising richness of non-resident fungi, including plant pathogens such as ergot (Claviceps purperea). Overall, fungal richness across indoor surfaces was high, but based on known autecologies, most of these fungi were unlikely to be growing on surfaces. We conclude that while some endogenous fungal growth on typical household surfaces does occur, particularly on drains and skin, all residential surfaces appear – to varying degrees – to be passive collectors of airborne fungi of putative outdoor origin, a view of the origins of the indoor microbiome quite different from bacteria. PMID:24223861

  6. Evaluation of Surface Sampling for Bacillus Spores Using ...

    EPA Pesticide Factsheets

    Journal Article In this study, commercially-available domestic cleaning robots were evaluated for spore surface sampling efficiency on common indoor surfaces. The current study determined the sampling efficiency of each robot, without modifying the sensors, algorithms, or logics set by the manufacturers.

  7. Monitoring airborne fungal spores in an experimental indoor environment to evaluate sampling methods and the effects of human activity on air sampling.

    PubMed Central

    Buttner, M P; Stetzenbach, L D

    1993-01-01

    Aerobiological monitoring was conducted in an experimental room to aid in the development of standardized sampling protocols for airborne microorganisms in the indoor environment. The objectives of this research were to evaluate the relative efficiencies of selected sampling methods for the retrieval of airborne fungal spores and to determine the effect of human activity on air sampling. Dry aerosols containing known concentrations of Penicillium chrysogenum spores were generated, and air samples were taken by using Andersen six-stage, Surface Air System, Burkard, and depositional samplers. The Andersen and Burkard samplers retrieved the highest numbers of spores compared with the measurement standard, an aerodynamic particle sizer located inside the room. Data from paired samplers demonstrated that the Andersen sampler had the highest levels of sensitivity and repeatability. With a carpet as the source of P. chrysogenum spores, the effects of human activity (walking or vacuuming near the sampling site) on air sampling were also examined. Air samples were taken under undisturbed conditions and after human activity in the room. Human activity resulted in retrieval of significantly higher concentrations of airborne spores. Surface sampling of the carpet revealed moderate to heavy contamination despite relatively low airborne counts. Therefore, in certain situations, air sampling without concomitant surface sampling may not adequately reflect the level of microbial contamination in indoor environments. PMID:8439150

  8. Phytoforensics: Trees as bioindicators of potential indoor exposure via vapor intrusion.

    PubMed

    Wilson, Jordan L; Samaranayake, V A; Limmer, Matt A; Burken, Joel G

    2018-01-01

    Human exposure to volatile organic compounds (VOCs) via vapor intrusion (VI) is an emerging public health concern with notable detrimental impacts on public health. Phytoforensics, plant sampling to semi-quantitatively delineate subsurface contamination, provides a potential non-invasive screening approach to detect VI potential, and plant sampling is effective and also time- and cost-efficient. Existing VI assessment methods are time- and resource-intensive, invasive, and require access into residential and commercial buildings to drill holes through basement slabs to install sampling ports or require substantial equipment to install groundwater or soil vapor sampling outside the home. Tree-core samples collected in 2 days at the PCE Southeast Contamination Site in York, Nebraska were analyzed for tetrachloroethene (PCE) and results demonstrated positive correlations with groundwater, soil, soil-gas, sub-slab, and indoor-air samples collected over a 2-year period. Because tree-core samples were not collocated with other samples, interpolated surfaces of PCE concentrations were estimated so that comparisons could be made between pairs of data. Results indicate moderate to high correlation with average indoor-air and sub-slab PCE concentrations over long periods of time (months to years) to an interpolated tree-core PCE concentration surface, with Spearman's correlation coefficients (ρ) ranging from 0.31 to 0.53 that are comparable to the pairwise correlation between sub-slab and indoor-air PCE concentrations (ρ = 0.55, n = 89). Strong correlations between soil-gas, sub-slab, and indoor-air PCE concentrations and an interpolated tree-core PCE concentration surface indicate that trees are valid indicators of potential VI and human exposure to subsurface environment pollutants. The rapid and non-invasive nature of tree sampling are notable advantages: even with less than 60 trees in the vicinity of the source area, roughly 12 hours of tree-core sampling with minimal equipment at the PCE Southeast Contamination Site was sufficient to delineate vapor intrusion potential in the study area and offered comparable delineation to traditional sub-slab sampling performed at 140 properties over a period of approximately 2 years.

  9. Phytoforensics: Trees as bioindicators of potential indoor exposure via vapor intrusion

    USGS Publications Warehouse

    Wilson, Jordan L.; Samaranayake, V.A.; Limmer, Matthew A.; Burken, Joel G.

    2018-01-01

    Human exposure to volatile organic compounds (VOCs) via vapor intrusion (VI) is an emerging public health concern with notable detrimental impacts on public health. Phytoforensics, plant sampling to semi-quantitatively delineate subsurface contamination, provides a potential non-invasive screening approach to detect VI potential, and plant sampling is effective and also time- and cost-efficient. Existing VI assessment methods are time- and resource-intensive, invasive, and require access into residential and commercial buildings to drill holes through basement slabs to install sampling ports or require substantial equipment to install groundwater or soil vapor sampling outside the home. Tree-core samples collected in 2 days at the PCE Southeast Contamination Site in York, Nebraska were analyzed for tetrachloroethene (PCE) and results demonstrated positive correlations with groundwater, soil, soil-gas, sub-slab, and indoor-air samples collected over a 2-year period. Because tree-core samples were not collocated with other samples, interpolated surfaces of PCE concentrations were estimated so that comparisons could be made between pairs of data. Results indicate moderate to high correlation with average indoor-air and sub-slab PCE concentrations over long periods of time (months to years) to an interpolated tree-core PCE concentration surface, with Spearman’s correlation coefficients (ρ) ranging from 0.31 to 0.53 that are comparable to the pairwise correlation between sub-slab and indoor-air PCE concentrations (ρ = 0.55, n = 89). Strong correlations between soil-gas, sub-slab, and indoor-air PCE concentrations and an interpolated tree-core PCE concentration surface indicate that trees are valid indicators of potential VI and human exposure to subsurface environment pollutants. The rapid and non-invasive nature of tree sampling are notable advantages: even with less than 60 trees in the vicinity of the source area, roughly 12 hours of tree-core sampling with minimal equipment at the PCE Southeast Contamination Site was sufficient to delineate vapor intrusion potential in the study area and offered comparable delineation to traditional sub-slab sampling performed at 140 properties over a period of approximately 2 years.

  10. Phytoforensics: Trees as bioindicators of potential indoor exposure via vapor intrusion

    PubMed Central

    2018-01-01

    Human exposure to volatile organic compounds (VOCs) via vapor intrusion (VI) is an emerging public health concern with notable detrimental impacts on public health. Phytoforensics, plant sampling to semi-quantitatively delineate subsurface contamination, provides a potential non-invasive screening approach to detect VI potential, and plant sampling is effective and also time- and cost-efficient. Existing VI assessment methods are time- and resource-intensive, invasive, and require access into residential and commercial buildings to drill holes through basement slabs to install sampling ports or require substantial equipment to install groundwater or soil vapor sampling outside the home. Tree-core samples collected in 2 days at the PCE Southeast Contamination Site in York, Nebraska were analyzed for tetrachloroethene (PCE) and results demonstrated positive correlations with groundwater, soil, soil-gas, sub-slab, and indoor-air samples collected over a 2-year period. Because tree-core samples were not collocated with other samples, interpolated surfaces of PCE concentrations were estimated so that comparisons could be made between pairs of data. Results indicate moderate to high correlation with average indoor-air and sub-slab PCE concentrations over long periods of time (months to years) to an interpolated tree-core PCE concentration surface, with Spearman’s correlation coefficients (ρ) ranging from 0.31 to 0.53 that are comparable to the pairwise correlation between sub-slab and indoor-air PCE concentrations (ρ = 0.55, n = 89). Strong correlations between soil-gas, sub-slab, and indoor-air PCE concentrations and an interpolated tree-core PCE concentration surface indicate that trees are valid indicators of potential VI and human exposure to subsurface environment pollutants. The rapid and non-invasive nature of tree sampling are notable advantages: even with less than 60 trees in the vicinity of the source area, roughly 12 hours of tree-core sampling with minimal equipment at the PCE Southeast Contamination Site was sufficient to delineate vapor intrusion potential in the study area and offered comparable delineation to traditional sub-slab sampling performed at 140 properties over a period of approximately 2 years. PMID:29451904

  11. Passive Sampling for Indoor and Outdoor Exposures to Chlorpyrifos, Azinphos-Methyl, and Oxygen Analogs in a Rural Agricultural Community.

    PubMed

    Gibbs, Jenna L; Yost, Michael G; Negrete, Maria; Fenske, Richard A

    2017-03-01

    Recent studies have highlighted the increased potency of oxygen analogs of organophosphorus pesticides. These pesticides and oxygen analogs have previously been identified in the atmosphere following spray applications in the states of California and Washington. We used two passive sampling methods to measure levels of the ollowing organophosphorus pesticides: chlorpyrifos, azinphos-methyl, and their oxygen analogs at 14 farmworker and 9 non-farmworker households in an agricultural region of central Washington State in 2011. The passive methods included polyurethane foam passive air samplers deployed outdoors and indoors and polypropylene deposition plates deployed indoors. We collected cumulative monthly samples during the pesticide application seasons and during the winter season as a control. Monthly outdoor air concentrations ranged from 9.2 to 199 ng/m 3 for chlorpyrifos, 0.03 to 20 ng/m 3 for chlorpyrifos-oxon, < LOD (limit of detection) to 7.3 ng/m 3 for azinphos-methyl, and < LOD to 0.8 ng/m 3 for azinphos-methyl-oxon. Samples from proximal households (≤ 250 m) had significantly higher outdoor air concentrations of chlorpyrifos, chlorpyrifos-oxon, and azinphos-methyl than did samples from nonproximal households ( p ≤ 0.02). Overall, indoor air concentrations were lower than outdoors. For example, all outdoor air samples for chlorpyrifos and 97% of samples for azinphos-methyl were > LOD. Indoors, only 78% of air samples for chlorpyrifos and 35% of samples for azinphos-methyl were > LOD. Samples from farmworker households had higher indoor air concentrations of both pesticides than did samples from non-farmworker households. Mean indoor and outdoor air concentration ratios for chlorpyrifos and azinphos-methyl were 0.17 and 0.44, respectively. We identified higher levels in air and on surfaces at both proximal and farmworker households. Our findings further confirm the presence of pesticides and their oxygen analogs in air and highlight their potential for infiltration of indoor living environments. Citation: Gibbs JL, Yost MG, Negrete M, Fenske RA. 2017. Passive sampling for indoor and outdoor exposures to chlorpyrifos, azinphos-methyl, and oxygen analogs in a rural agricultural community. Environ Health Perspect 125:333-341; http://dx.doi.org/10.1289/EHP425.

  12. Indoor air quality investigation and health risk assessment at correctional institutions.

    PubMed

    Ofungwu, Joseph

    2005-04-01

    A comprehensive indoor air-quality (IAQ) investigation was conducted at a state correctional facility in New Jersey, USA with a lengthy history of IAQ problems. The IAQ investigation comprised preliminary indoor air screening using direct readout instrumentation, indoor air/surface wipe sampling and laboratory analysis, as well as a heating, ventilation, and air-conditioning system evaluation, and a building envelope survey. In addition to air sampling, a human health risk assessment was performed to evaluate the potential for exposure to site-related air contaminants with respect to the inmate and worker populations. The risk assessment results for the prison facility indicated the potential for significant health risks for the inmate population, possibly reflecting the effects of their confinement and extended exposure to indoor air contaminants, as compared to the prison guard and worker population. Based on the results of the risk assessment, several mitigation measures are recommended to minimize prison population health risks and improve indoor air quality at prison facilities.

  13. Distribution of 2,4-D in air and on surfaces inside residences after lawn applications: comparing exposure estimates from various media for young children.

    PubMed Central

    Nishioka, M G; Lewis, R G; Brinkman, M C; Burkholder, H M; Hines, C E; Menkedick, J R

    2001-01-01

    We collected indoor air, surface wipes (floors, table tops, and window sills), and floor dust samples at multiple locations within 11 occupied and two unoccupied homes both before and after lawn application of the herbicide 2,4-D. We measured residues 1 week before and after application. We used collected samples to determine transport routes of 2,4-D from the lawn into the homes, its subsequent distribution between the indoor surfaces, and air concentration as a function of airborne particle size. We used residue measurements to estimate potential exposures within these homes. After lawn application, 2,4-D was detected in indoor air and on all surfaces throughout all homes. Track-in by an active dog and by the homeowner applicator were the most significant factors for intrusion. Resuspension of floor dust was the major source of 2,4-D in indoor air, with highest levels of 2,4-D found in the particle size range of 2.5-10 microm. Resuspended floor dust was also a major source of 2,4-D on tables and window sills. Estimated postapplication indoor exposure levels for young children from nondietary ingestion may be 1-10 microg/day from contact with floors, and 0.2-30 microg/day from contact with table tops. These are estimated to be about 10 times higher than the preapplication exposures. By comparison, dietary ingestion of 2,4-D is approximately 1.3 microg/day. PMID:11713005

  14. Occurrence, Distribution, and Accumulation of Pesticides in Exterior Residential Areas.

    PubMed

    Jiang, Weiying; Conkle, Jeremy L; Luo, Yuzhou; Li, Juying; Xu, Karen; Gan, Jay

    2016-12-06

    Pesticides are commonly applied around residential homes, but their occurrence on exterior surfaces (e.g., pavement) has not been thoroughly evaluated. We collected 360 dust samples from curbside gutters, sidewalks, and street surfaces at 40 houses in southern California to evaluate pesticide occurrence on urban paved surfaces as well as their spatial and temporal distributions. Pesticides and select degradates were ubiquitously detected in dust, with the median concentration of total target analytes at 85 μg kg -1 . A total of 75% of samples contained at least five pesticides. As a result of recurring pesticide applications, concentrations increased throughout the summer. The pyrethroids bifenthrin and permethrin accounted for 55% of total pesticides detected in the dust. The highest concentrations in dust were found on the sidewalk and in the gutter. Relative to indoor environments, human exposure risk to pesticides on paved surfaces was estimated to be lower, with the highest potential oral and dermal exposure predicted to be 38 ng day -1 for permethrin. The ubiquitous detection of pesticides on residential outdoor surfaces and the fact that the exterior concentrations did not correlate to the indoor areas highlight the necessity to measure pesticides in both indoor and outdoor areas for complete residential pesticide risk assessment.

  15. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF DISLODGEABLE RESIDUES -- PUF ROLLER SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.18)

    EPA Science Inventory

    This SOP describes the method to collect transferable residues from indoor floor surfaces. The sampling procedures described are applicable to bare floors or covered floor surfaces, e.g., carpeting and vinyl flooring. The samples will be collected only in the day care centers o...

  16. [Health impact of indoor mineral particle pollution].

    PubMed

    Vincent, M; Chemarin, C

    2011-04-01

    Mineral particle air pollution consists of both atmospheric pollution and indoor pollution. Indoor pollution comes from household products, cosmetics, combustion used to heat homes or cook food, smoking, hobbies or odd jobs. There is strong evidence that acute respiratory infections in children and chronic obstructive pulmonary disease in women are associated with indoor biomass smoke. Detailed questioning is essential to identify at risk activities and sampling of airborne particles may help with the identification of pollution risks. Particle elimination depends on the standard of ventilation of the indoor environment. Five per cent of French homes have levels of pollution greater than 180 μg/m³ for PM 10 and 2% for PM 2.5. The principal mineral particle air pollutants are probably silica, talc, asbestos and carbon, whereas tobacco smoke leads to exposure to various ultrafine particles. The toxicity of these particles could be more related to surface exchange than to density. Tissue measurements by electron microscopy and microanalysis of particle samples may identify an uptake of particles similar to those in the environmental sample. Copyright © 2011. Published by Elsevier Masson SAS.

  17. Indoor radiocaesium contamination in residential houses within evacuation areas after the Fukushima nuclear accident

    PubMed Central

    Yoshida-Ohuchi, Hiroko; Kanagami, Takashi; Satoh, Yasushi; Hosoda, Masahiro; Naitoh, Yutaka; Kameyama, Mizuki

    2016-01-01

    Indoor contaminants were investigated from July 2013 to January 2015 within ninety-five residential houses in five evacuation zones, Iitate village, Odaka district, and the towns of Futaba, Okuma, and Tomioka. A dry smear test was applied to the surface of materials and structures in rooms and in the roof-space of houses. We found that 134Cs and 137Cs were the dominant radionuclides in indoor surface contamination, and there was a distance dependence from the Fukushima Daiichi nuclear power plant (FDNPP). For surface contamination in Iitate village (29–49 km from the FDNPP), 24.8% of samples exceeded the detection limit, which is quite a low value, while in Okuma (<3.0 km from the FDNPP), 99.7% of samples exceeded the detection limit and surface contamination levels exceeded 20 Bq/cm2 (the value was corrected to March 2011). In residential houses in Okuma, Futaba, and Tomioka, closer to the FDNPP than those in Odaka district and Iitate village, surface contamination was inversely proportional to the square of the distance between a house and the FDNPP. In the houses closest to the FDNPP, the contribution of surface contamination to the ambient dose equivalent rate was evaluated to be approximately 0.3 μSv/h. PMID:27212076

  18. Decontamination assessment of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surfaces using a hydrogen peroxide gas generator.

    PubMed

    Rogers, J V; Sabourin, C L K; Choi, Y W; Richter, W R; Rudnicki, D C; Riggs, K B; Taylor, M L; Chang, J

    2005-01-01

    To evaluate the decontamination of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surface materials using hydrogen peroxide gas. Bacillus anthracis, B. subtilis, and G. stearothermophilus spores were dried on seven types of indoor surfaces and exposed to > or =1000 ppm hydrogen peroxide gas for 20 min. Hydrogen peroxide exposure significantly decreased viable B. anthracis, B. subtilis, and G. stearothermophilus spores on all test materials except G. stearothermophilus on industrial carpet. Significant differences were observed when comparing the reduction in viable spores of B. anthracis with both surrogates. The effectiveness of gaseous hydrogen peroxide on the growth of biological indicators and spore strips was evaluated in parallel as a qualitative assessment of decontamination. At 1 and 7 days postexposure, decontaminated biological indicators and spore strips exhibited no growth, while the nondecontaminated samples displayed growth. Significant differences in decontamination efficacy of hydrogen peroxide gas on porous and nonporous surfaces were observed when comparing the mean log reduction in B. anthracis spores with B. subtilis and G. stearothermophilus spores. These results provide comparative information for the decontamination of B. anthracis spores with surrogates on indoor surfaces using hydrogen peroxide gas.

  19. Passive Sampling for Indoor and Outdoor Exposures to Chlorpyrifos, Azinphos-Methyl, and Oxygen Analogs in a Rural Agricultural Community

    PubMed Central

    Gibbs, Jenna L.; Yost, Michael G.; Negrete, Maria; Fenske, Richard A.

    2016-01-01

    Background: Recent studies have highlighted the increased potency of oxygen analogs of organophosphorus pesticides. These pesticides and oxygen analogs have previously been identified in the atmosphere following spray applications in the states of California and Washington. Objectives: We used two passive sampling methods to measure levels of the ollowing organophosphorus pesticides: chlorpyrifos, azinphos-methyl, and their oxygen analogs at 14 farmworker and 9 non-farmworker households in an agricultural region of central Washington State in 2011. Methods: The passive methods included polyurethane foam passive air samplers deployed outdoors and indoors and polypropylene deposition plates deployed indoors. We collected cumulative monthly samples during the pesticide application seasons and during the winter season as a control. Results: Monthly outdoor air concentrations ranged from 9.2 to 199 ng/m3 for chlorpyrifos, 0.03 to 20 ng/m3 for chlorpyrifos-oxon, < LOD (limit of detection) to 7.3 ng/m3 for azinphos-methyl, and < LOD to 0.8 ng/m3 for azinphos-methyl-oxon. Samples from proximal households (≤ 250 m) had significantly higher outdoor air concentrations of chlorpyrifos, chlorpyrifos-oxon, and azinphos-methyl than did samples from nonproximal households (p ≤ 0.02). Overall, indoor air concentrations were lower than outdoors. For example, all outdoor air samples for chlorpyrifos and 97% of samples for azinphos-methyl were > LOD. Indoors, only 78% of air samples for chlorpyrifos and 35% of samples for azinphos-methyl were > LOD. Samples from farmworker households had higher indoor air concentrations of both pesticides than did samples from non-farmworker households. Mean indoor and outdoor air concentration ratios for chlorpyrifos and azinphos-methyl were 0.17 and 0.44, respectively. Conclusions: We identified higher levels in air and on surfaces at both proximal and farmworker households. Our findings further confirm the presence of pesticides and their oxygen analogs in air and highlight their potential for infiltration of indoor living environments. Citation: Gibbs JL, Yost MG, Negrete M, Fenske RA. 2017. Passive sampling for indoor and outdoor exposures to chlorpyrifos, azinphos-methyl, and oxygen analogs in a rural agricultural community. Environ Health Perspect 125:333–341; http://dx.doi.org/10.1289/EHP425 PMID:27517732

  20. APPLICATION OF SEMIPERMEABLE MEMBRANE DEVICES TO INDOOR AIR SAMPLING

    EPA Science Inventory

    Semipermeable membrane devices (SPMDs) are a relatively new passive sampling technique for nonpolar organic compounds that have been extensively used for surface water sampling. A small body of literature indicates that SPMDs are also useful for air sampling. Because SPMDs ha...

  1. Extraction of Aerosol-Deposited Yersinia pestis from Indoor Surfaces To Determine Bacterial Environmental Decay.

    PubMed

    Gut, Ian M; Bartlett, Ryan A; Yeager, John J; Leroux, Brian; Ratnesar-Shumate, Shanna; Dabisch, Paul; Karaolis, David K R

    2016-05-01

    Public health and decontamination decisions following an event that causes indoor contamination with a biological agent require knowledge of the environmental persistence of the agent. The goals of this study were to develop methods for experimentally depositing bacteria onto indoor surfaces via aerosol, evaluate methods for sampling and enumerating the agent on surfaces, and use these methods to determine bacterial surface decay. A specialized aerosol deposition chamber was constructed, and methods were established for reproducible and uniform aerosol deposition of bacteria onto four coupon types. The deposition chamber facilitated the control of relative humidity (RH; 10 to 70%) following particle deposition to mimic the conditions of indoor environments, as RH is not controlled by standard heating, ventilation, and air conditioning (HVAC) systems. Extraction and culture-based enumeration methods to quantify the viable bacteria on coupons were shown to be highly sensitive and reproducible. To demonstrate the usefulness of the system for decay studies,Yersinia pestis persistence as a function of surface type at 21 °C and 40% RH was determined to be >40%/min for all surfaces. Based upon these results, at typical indoor temperature and RH, a 6-log reduction in titer would expected to be achieved within 1 h as the result of environmental decay on surfaces without active decontamination. The developed approach will facilitate future persistence and decontamination studies with a broad range of biological agents and surfaces, providing agent decay data to inform both assessments of risk to personnel entering a contaminated site and decontamination decisions following biological contamination of an indoor environment. Public health and decontamination decisions following contamination of an indoor environment with a biological agent require knowledge of the environmental persistence of the agent. Previous studies on Y. pestis persistence have utilized large liquid droplet deposition to provide persistence data. As a result, methods were developed to deposit aerosols containing bacteria onto indoor surfaces, reproducibly enumerate bacteria harvested from coupons, and determine surface decay utilizing Y. pestis The results of this study provide foundational methods required to evaluate surface decay of bacteria and potentially other biological agents, such as viruses, in aerosol particles as a function of surface type and environment. Integrating the data from both aerosol and liquid deposition surface decay studies will provide medical and public health personnel with a more complete understanding of agent persistence on surfaces in contaminated areas for assessment of health risks and to inform decontamination decisions. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  2. Extraction of Aerosol-Deposited Yersinia pestis from Indoor Surfaces To Determine Bacterial Environmental Decay

    PubMed Central

    Bartlett, Ryan A.; Yeager, John J.; Leroux, Brian; Ratnesar-Shumate, Shanna; Dabisch, Paul

    2016-01-01

    ABSTRACT Public health and decontamination decisions following an event that causes indoor contamination with a biological agent require knowledge of the environmental persistence of the agent. The goals of this study were to develop methods for experimentally depositing bacteria onto indoor surfaces via aerosol, evaluate methods for sampling and enumerating the agent on surfaces, and use these methods to determine bacterial surface decay. A specialized aerosol deposition chamber was constructed, and methods were established for reproducible and uniform aerosol deposition of bacteria onto four coupon types. The deposition chamber facilitated the control of relative humidity (RH; 10 to 70%) following particle deposition to mimic the conditions of indoor environments, as RH is not controlled by standard heating, ventilation, and air conditioning (HVAC) systems. Extraction and culture-based enumeration methods to quantify the viable bacteria on coupons were shown to be highly sensitive and reproducible. To demonstrate the usefulness of the system for decay studies, Yersinia pestis persistence as a function of surface type at 21°C and 40% RH was determined to be >40%/min for all surfaces. Based upon these results, at typical indoor temperature and RH, a 6-log reduction in titer would expected to be achieved within 1 h as the result of environmental decay on surfaces without active decontamination. The developed approach will facilitate future persistence and decontamination studies with a broad range of biological agents and surfaces, providing agent decay data to inform both assessments of risk to personnel entering a contaminated site and decontamination decisions following biological contamination of an indoor environment. IMPORTANCE Public health and decontamination decisions following contamination of an indoor environment with a biological agent require knowledge of the environmental persistence of the agent. Previous studies on Y. pestis persistence have utilized large liquid droplet deposition to provide persistence data. As a result, methods were developed to deposit aerosols containing bacteria onto indoor surfaces, reproducibly enumerate bacteria harvested from coupons, and determine surface decay utilizing Y. pestis. The results of this study provide foundational methods required to evaluate surface decay of bacteria and potentially other biological agents, such as viruses, in aerosol particles as a function of surface type and environment. Integrating the data from both aerosol and liquid deposition surface decay studies will provide medical and public health personnel with a more complete understanding of agent persistence on surfaces in contaminated areas for assessment of health risks and to inform decontamination decisions. PMID:26944839

  3. Nitrogen Dioxide in Indoor Ice Skating Facilities: An International Survey.

    PubMed

    Brauer, Michael; Lee, Kiyoung; Spengler, John D; Salonen, Raimo O; Pennanen, Arto; Braathen, Ole Anders; Miskovic, Eva Mihalikova And Peter; Nozaki, Atsuo; Tsuzuki, Toshifumi; Rui-Jin, Song; Qing-Xiang, Yang Xu And Zeng; Drahonovska, Hana; Kjaergaard, Søren

    1997-10-01

    An international survey of nitrogen dioxide (NO 2 ) levels inside indoor ice skating facilities was conducted. One-week average NO 2 concentrations were measured inside and outside of 332 ice rinks located in nine countries. Each rink manager also completed a questionnaire describing the building, the resurfacing machines, and their use patterns. The (arithmetic) mean NO 2 level for all rinks in the study was 228 ppb, with a range of 1-2,680 ppb, based on a sample collected at breathing height and adjacent to the ice surface. The mean of the second indoor sample (collected at a spectator's area) was 221 ppb, with a range of 1-3,175 ppb. The ratio of the indoor to outdoor NO 2 concentrations was above 1 for 95% of the rinks sampled, indicating the presence of an indoor NO 2 source (mean indoor:outdoor ratio = 20). Estimates of short-term NO 2 concentrations indicated that as many as 40% of the sampled rinks would have exceeded the World Health Organization 1-hour guideline value of 213 ppb NO 2 for indoor air. Statistically significant associations were observed between NO 2 levels and the type of fuel used to power the resurfacer, the absence of a catalytic converter on a resurfacer, and the use of an ice edger. There were also indications that decreased use of mechanical ventilation, increased number of resurfacing operations per day, and smaller rink volumes were associated with increased NO 2 levels. In rinks where the main resurfacer was powered by propane, the NO 2 concentrations were higher than in those with gasoline-powered resurfacers, while the latter had NO 2 concentrations higher than in those using diesel. Rinks where the main resurfacer was electric had the lowest indoor NO 2 concentrations, similar to the levels measured outdoor.

  4. Molds and mycotoxins in indoor environments--a survey in water-damaged buildings.

    PubMed

    Bloom, Erica; Nyman, Eva; Must, Aime; Pehrson, Christina; Larsson, Lennart

    2009-11-01

    Mycotoxins are toxic, secondary metabolites frequently produced by molds in water-damaged indoor environments. We studied the prevalence of selected, potent mycotoxins and levels of fungal biomass in samples collected from water-damaged indoor environments in Sweden during a 1-year period. One hundred samples of building materials, 18 samples of settled dust, and 37 samples of cultured dust were analyzed for: (a) mycoflora by microscopy and culture; (b) fungal chemical marker ergosterol and hydrolysis products of macrocyclic trichothecenes and trichodermin (verrucarol and trichodermol) by gas chromatography-tandem mass spectrometry; and (c) sterigmatocystin, gliotoxin, aflatoxin B(1), and satratoxin G and H by high performance liquid chromatography-tandem mass spectrometry. Sixty-six percent of the analyzed building materials samples, 11% of the settled dust samples, and 51% of the cultured dust samples were positive for at least one of the studied mycotoxins. In addition, except in the case of gliotoxin, mycotoxin-positive building material samples contained 2-6 times more ergosterol than mycotoxin-negative samples. We show that (a) molds growing on a range of different materials indoors in water-damaged buildings generally produce mycotoxins, and (b) mycotoxin-containing particles in mold-contaminated environments may settle on surfaces above floor level. The mass spectrometry methods used in this study are valuable tools in further research to survey mycotoxin exposure and investigate potential links with health effects.

  5. Comparison of indoor air sampling and dust collection methods for fungal exposure assessment using quantitative PCR.

    PubMed

    Cox, Jennie; Indugula, Reshmi; Vesper, Stephen; Zhu, Zheng; Jandarov, Roman; Reponen, Tiina

    2017-10-18

    Evaluating fungal contamination indoors is complicated because of the many different sampling methods utilized. In this study, fungal contamination was evaluated using five sampling methods and four matrices for results. The five sampling methods were a 48 hour indoor air sample collected with a Button™ inhalable aerosol sampler and four types of dust samples: a vacuumed floor dust sample, newly settled dust collected for four weeks onto two types of electrostatic dust cloths (EDCs) in trays, and a wipe sample of dust from above floor surfaces. The samples were obtained in the bedrooms of asthmatic children (n = 14). Quantitative polymerase chain reaction (qPCR) was used to analyze the dust and air samples for the 36 fungal species that make up the Environmental Relative Moldiness Index (ERMI). The results from the samples were compared by four matrices: total concentration of fungal cells, concentration of fungal species associated with indoor environments, concentration of fungal species associated with outdoor environments, and ERMI values (or ERMI-like values for air samples). The ERMI values for the dust samples and the ERMI-like values for the 48 hour air samples were not significantly different. The total cell concentrations of the 36 species obtained with the four dust collection methods correlated significantly (r = 0.64-0.79, p < 0.05), with the exception of the vacuumed floor dust and newly settled dust. In addition, fungal cell concentrations of indoor associated species correlated well between all four dust sampling methods (r = 0.68-0.86, p < 0.01). No correlation was found between the fungal concentrations in the air and dust samples primarily because of differences in concentrations of Cladosporium cladosporioides Type 1 and Epicoccum nigrum. A representative type of dust sample and a 48 hour air sample might both provide useful information about fungal exposures.

  6. Development and evaluation of mosquito-electrocuting traps as alternatives to the human landing catch technique for sampling host-seeking malaria vectors.

    PubMed

    Maliti, Deodatus V; Govella, Nicodem J; Killeen, Gerry F; Mirzai, Nosrat; Johnson, Paul C D; Kreppel, Katharina; Ferguson, Heather M

    2015-12-15

    The human landing catch (HLC) is the gold standard method for sampling host-seeking malaria vectors. However, the HLC is ethically questionable because it requires exposure of humans to potentially infectious mosquito bites. Two exposure-free methods for sampling host-seeking mosquitoes were evaluated using electrocuting surfaces as potential replacements for HLC: (1) a previously evaluated, commercially available electrocuting grid (CA-EG) designed for killing flies, and (2) a custom-made mosquito electrocuting trap (MET) designed to kill African malaria vectors. The MET and the CA-EG were evaluated relative to the HLC in a Latin Square experiment conducted in the Kilombero Valley, Tanzania. The sampling consistency of the traps across the night and at varying mosquito densities was investigated. Estimates of the proportion of mosquitoes caught indoors (P(i)), proportion of human exposure occurring indoors (π(i)), and proportion of mosquitoes caught when most people are likely to be indoors (P(fl)) were compared for all traps. Whereas the CA-EG performed poorly (<10% of catch of HLC), sampling efficiency of the MET for sampling Anopheles funestus s.l. was indistinguishable from HLC indoors and outdoors. For Anopheles gambiae s.l., sampling sensitivity of MET was 20.9% (95% CI 10.3-42.2) indoors and 58.5% (95% CI 32.2-106.2) outdoors relative to HLC. There was no evidence of density-dependent sampling by the MET or CA-EG. Similar estimates of P(i) were obtained for An. gambiae s.l. and An. funestus s.l. from all trapping methods. The proportion of mosquitoes caught when people are usually indoors (P(fl)) was underestimated by the CA-EG and MET for An. gambiae s.l., but similar to the HLC for An. funestus. Estimates of the proportion of human exposure occurring indoors (π(i)) obtained from the CA-EG and MET were similar to the HLC for An. gambiae s.l., but overestimated for An. funestus. The MET showed promise as an outdoor sampling tool for malaria vectors where it achieved >50% sampling sensitivity relative to the HLC. The CA-EG had poor sampling sensitivity outdoors and inside. With further modification, the MET could provide an efficient and safer alternative to the HLC for the surveillance of mosquito vectors outdoors.

  7. Metal carboxylate formation during indoor atmospheric corrosion of Cu, Zn, and Ni

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Persson, D.; Leygraf, C.

    Chemical analyses of surface films and corrosion products formed on pure Cu, Zn, Ni, and Ag samples exposed up to 12 months in various mild indoor environments have been performed by infrared reflection-absorption spectroscopy (IRAS) and X-ray photoelectron spectroscopy. The analyses reveal metal carboxylates to be the main ingredients on the surface of Cu, Zn, and Ni. Other ions, such as sulfate, chloride, nitrate, and ammonium ions are also present but in smaller amounts.The surface region on Ag contains mainly silver sulfide with smaller amounts of sulfate, ammonium, and chloride ions. The growth of the carboxylate layers, as followed bymore » IRAS, exhibits an initial film formation with a thickness of a few nanometers for all exposure sites investigated. Subsequent growth to thicker layers was observed at sites with higher humidity levels. The unexpectedly high content of metal carboxylates found on Cu, Zn, and Ni may provide insight into possible processes involved in the atmospheric indoor corrosion of these metals.« less

  8. The Health Risks of Belgian Illicit Indoor Cannabis Plantations.

    PubMed

    Vanhove, Wouter; Cuypers, Eva; Bonneure, Arne-Jan; Gotink, Joachim; Stassen, Mirna; Tytgat, Jan; Van Damme, Patrick

    2018-04-10

    We assessed the prevalence of potential health hazards to intervention staff and cannabis growers in Belgian indoor cannabis plantations. Surface mold swab samples were taken at 16 Belgian indoor plantations contained mostly Penicillium sp. and Aspergillus sp. However, their precise health impact on intervention staff and illicit growers is unclear as no molds spore concentrations were measured. Atmospheric gas monitoring in the studied cannabis plantations did not reveal dangerous toxic substances. Health symptoms were reported by 60% of 221 surveyed police, but could not be linked to specific plantation characteristics. We conclude that Belgian indoor cannabis plantations pose a potential health threat to growers and intervention staff. AS there are currently no clear safety guidelines for seizure and dismantling of Belgian indoor cannabis plantations, we recommend first responders to follow strict safety rules when entering the growth rooms, which include wearing appropriate personal protective equipment. © 2018 American Academy of Forensic Sciences.

  9. Athletic equipment microbiota are shaped by interactions with human skin

    DOE PAGES

    Wood, Mariah; Gibbons, Sean M.; Lax, Simon; ...

    2015-06-19

    Background: Americans spend the vast majority of their lives in built environments. Even traditionally outdoor pursuits, such as exercising, are often now performed indoors. Bacteria that colonize these indoor ecosystems are primarily derived from the human microbiome. The modes of human interaction with indoor surfaces and the physical conditions associated with each surface type determine the steady-state ecology of the microbial community. Results: Bacterial assemblages associated with different surfaces in three athletic facilities, including floors, mats, benches, free weights, and elliptical handles, were sampled every other hour (8 am to 6 pm) for 2 days. Surface and equipment type hadmore » a stronger influence on bacterial community composition than the facility in which they were housed. Surfaces that were primarily in contact with human skin exhibited highly dynamic bacterial community composition and non-random co-occurrence patterns, suggesting that different host microbiomes—shaped by selective forces—were being deposited on these surfaces through time. Bacterial assemblages found on the floors and mats changed less over time, and species co-occurrence patterns appeared random, suggesting more neutral community assembly. Conclusions: These longitudinal patterns highlight the dramatic turnover of microbial communities on surfaces in regular contact with human skin. By uncovering these longitudinal patterns, this study promotes a better understanding of microbe-human interactions within the built environment.« less

  10. PAH EXPOSURES OF NINE PRESCHOOL CHILDREN

    EPA Science Inventory

    The exposures to 20 polycyclic aromatic hydrocarbons (PAH) of 9 children, ages 2-5 yr, were measured over 48 hr at day care and at home. Sampled media included indoor and outdoor air, floor dust, outdoor play area soil, hand surface, and solid and liquid food. Urine samples ...

  11. Chlorpyrifos accumulation patterns for child-accessible surfaces and objects and urinary metabolite excretion by children for 2 weeks after crack-and-crevice application.

    PubMed

    Hore, Paromita; Robson, Mark; Freeman, Natalie; Zhang, Jim; Wartenberg, Daniel; Ozkaynak, Halûk; Tulve, Nicolle; Sheldon, Linda; Needham, Larry; Barr, Dana; Lioy, Paul J

    2005-02-01

    The Children's Post-Pesticide Application Exposure Study (CPPAES) was conducted to look at the distribution of chlorpyrifos within a home environment for 2 weeks after a routine professional crack-and-crevice application and to determine the amount of the chlorpyrifos that is absorbed by a child living within the home. Ten residential homes with a 2- to 5-year-old child in each were selected for study, and the homes were treated with chlorpyrifos. Pesticide measurements were made from the indoor air, indoor surfaces, and plush toys. In addition, periodic morning urine samples were collected from each of the children throughout the 2-week period. We analyzed the urine samples for 3,5,6-trichloropyridinol, the primary urinary metabolite of chlorpyrifos, and used the results to estimate the children's absorbed dose. Average chlorpyrifos levels in the indoor air and surfaces were 26 (pretreatment)/120 (posttreatment) ng/m3 and 0.48 (pretreatment)/2.8 (posttreatment) ng/cm2, respectively, reaching peak levels between days 0 and 2; subsequently, concentrations decreased throughout the 2-week period. Chlorpyrifos in/on the plush toys ranged from 7.3 to 1,949 ng/toy postapplication, with concentrations increasing throughout the 2-week period, demonstrating a cumulative adsorption/absorption process indoors. The daily amount of chlorpyrifos estimated to be absorbed by the CPPAES children postapplication ranged from 0.04 to 4.8 microg/kg/day. During the 2 weeks after the crack-and-crevice application, there was no significant increase in the amount of chlorpyrifos absorbed by the CPPAES children.

  12. Distribution and congener profiles of short-chain chlorinated paraffins in indoor/outdoor glass window surface films and their film-air partitioning in Beijing, China.

    PubMed

    Gao, Wei; Wu, Jing; Wang, Yawei; Jiang, Guibin

    2016-02-01

    Short-chain chlorinated paraffins (SCCPs) are a group of n-alkanes with carbon chain length of 10-13. In this work, paired indoor/outdoor samples of organic films on window glass surfaces from urban buildings in Beijing, China, were collected to measure the concentrations and congener distributions of SCCPs. The total SCCP levels ranged from 337 ng/m(2) to 114 μg/m(2), with total organic carbon (TOC) normalized concentrations of 365 μg/m(2)-365 mg/m(2). Overall, the concentrations of SCCPs on the interior films were higher than the concentrations on the exterior films, suggesting an important indoor environmental exposure of SCCPs to the general public. A significant linear relationship was found between the SCCP concentrations and TOC, with a correlation coefficient of R = 0.34 (p < 0.01). A film-air partitioning model suggests that the indoor gas-phase SCCPs are related to their corresponding window film levels. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Impact of surface ozone interactions on indoor air chemistry: A modeling study.

    PubMed

    Kruza, M; Lewis, A C; Morrison, G C; Carslaw, N

    2017-09-01

    An INdoor air Detailed Chemical Model was developed to investigate the impact of ozone reactions with indoor surfaces (including occupants), on indoor air chemistry in simulated apartments subject to ambient air pollution. The results are consistent with experimental studies showing that approximately 80% of ozone indoors is lost through deposition to surfaces. The human body removes ozone most effectively from indoor air per square meter of surface, but the most significant surfaces for C 6 -C 10 aldehyde formation are soft furniture and painted walls owing to their large internal surfaces. Mixing ratios of between 8 and 11 ppb of C 6 -C 10 aldehydes are predicted to form in apartments in various locations in summer, the highest values are when ozone concentrations are enhanced outdoors. The most important aldehyde formed indoors is predicted to be nonanal (5-7 ppb), driven by oxidation-derived emissions from painted walls. In addition, ozone-derived emissions from human skin were estimated for a small bedroom at nighttime with concentrations of nonanal, decanal, and 4-oxopentanal predicted to be 0.5, 0.7, and 0.7 ppb, respectively. A detailed chemical analysis shows that ozone-derived surface aldehyde emissions from materials and people change chemical processing indoors, through enhanced formation of nitrated organic compounds and decreased levels of oxidants. © 2017 The Authors. Indoor Air Published by John Wiley & Sons Ltd.

  14. Influence of relative humidity on VOC concentrations in indoor air.

    PubMed

    Markowicz, Pawel; Larsson, Lennart

    2015-04-01

    Volatile organic compounds (VOCs) may be emitted from surfaces indoors leading to compromised air quality. This study scrutinized the influence of relative humidity (RH) on VOC concentrations in a building that had been subjected to water damage. While air samplings in a damp room at low RH (21-22%) only revealed minor amounts of 2-ethylhexanol (3 μg/m(3)) and 2,2,4-trimethyl-1,3-pentanediol diisobutyrate (TXIB, 8 μg/m(3)), measurements performed after a rapid increase of RH (to 58-75%) revealed an increase in VOC concentrations which was 3-fold for 2-ethylhexanol and 2-fold for TXIB. Similar VOC emission patterns were found in laboratory analyses of moisture-affected and laboratory-contaminated building materials. This study demonstrates the importance of monitoring RH when sampling indoor air for VOCs in order to avoid misleading conclusions from the analytical results.

  15. Flow-based ammonia gas analyzer with an open channel scrubber for indoor environments.

    PubMed

    Ohira, Shin-Ichi; Heima, Minako; Yamasaki, Takayuki; Tanaka, Toshinori; Koga, Tomoko; Toda, Kei

    2013-11-15

    A robust and fully automated indoor ammonia gas monitoring system with an open channel scrubber (OCS) was developed. The sample gas channel dimensions, hydrophilic surface treatment to produce a thin absorbing solution layer, and solution flow rate of the OCS were optimized to connect the OCS as in-line gas collector and avoid sample humidity effects. The OCS effluent containing absorbed ammonia in sample gas was injected into a derivatization solution flow. Derivatization was achieved with o-phthalaldehyde and sulfite in pH 11 buffer solution. The product, 1-sulfonateisoindole, is detected with a home-made fluorescence detector. The limit of detection of the analyzer based on three times the standard deviation of baseline noise was 0.9 ppbv. Sample gas could be analyzed 40 times per hour. Furthermore, relative humidity of up to 90% did not interfere considerably with the analyzer. Interference from amines was not observed. The developed gas analysis system was calibrated using a solution-based method. The system was used to analyze ammonia in an indoor environment along with an off-site method, traditional impinger gas collection followed by ion chromatographic analysis, for comparison. The results obtained using both methods agreed well. Therefore, the developed system can perform on-site monitoring of ammonia in indoor environments with improved time resolution compared with that of other methods. Crown Copyright © 2013 Published by Elsevier B.V. All rights reserved.

  16. Chlorpyrifos Accumulation Patterns for Child-Accessible Surfaces and Objects and Urinary Metabolite Excretion by Children for 2 Weeks after Crack-and-Crevice Application

    PubMed Central

    Hore, Paromita; Robson, Mark; Freeman, Natalie; Zhang, Jim; Wartenberg, Daniel; Özkaynak, Halûk; Tulve, Nicolle; Sheldon, Linda; Needham, Larry; Barr, Dana; Lioy, Paul J.

    2005-01-01

    The Children’s Post-Pesticide Application Exposure Study (CPPAES) was conducted to look at the distribution of chlorpyrifos within a home environment for 2 weeks after a routine professional crack-and-crevice application and to determine the amount of the chlorpyrifos that is absorbed by a child living within the home. Ten residential homes with a 2- to 5-year-old child in each were selected for study, and the homes were treated with chlorpyrifos. Pesticide measurements were made from the indoor air, indoor surfaces, and plush toys. In addition, periodic morning urine samples were collected from each of the children throughout the 2-week period. We analyzed the urine samples for 3,5,6-trichloropyridinol, the primary urinary metabolite of chlorpyrifos, and used the results to estimate the children’s absorbed dose. Average chlorpyrifos levels in the indoor air and surfaces were 26 (pretreatment)/120 (posttreatment) ng/m3 and 0.48 (pretreatment)/2.8 (posttreatment) ng/cm2, respectively, reaching peak levels between days 0 and 2; subsequently, concentrations decreased throughout the 2-week period. Chlorpyrifos in/on the plush toys ranged from 7.3 to 1,949 ng/toy postapplication, with concentrations increasing throughout the 2-week period, demonstrating a cumulative adsorption/absorption process indoors. The daily amount of chlorpyrifos estimated to be absorbed by the CPPAES children postapplication ranged from 0.04 to 4.8 μg/kg/day. During the 2 weeks after the crack-and-crevice application, there was no significant increase in the amount of chlorpyrifos absorbed by the CPPAES children. PMID:15687060

  17. FORMALDEHYDE GAS INACTIVATION OF BACILLUS ANTHRACIS, BACILLUS SUBTILIS AND GEOBACILLUS STEAROTHERMOPHILUS SPORES ON INDOOR SURFACE MATERIALS.

    EPA Science Inventory

    Research evaluated the decontamination of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surface material using formaldehyde gas. Spores were dried on seven types of indoor surfaces and exposed to 1100 ppm formaldehyde gas for 10 hr. Fo...

  18. Impact of indoor surface material on perceived air quality.

    PubMed

    Senitkova, I

    2014-03-01

    The material combination impact on perceived indoor air quality for various surface interior materials is presented in this paper. The chemical analysis and sensory assessments identifies health adverse of indoor air pollutants (TVOCs). In this study, emissions and odors from different common indoor surface materials were investigated in glass test chamber under standardized conditions. Chemical measurements (TVOC concentration) and sensory assessments (odor intensity, air acceptability) were done after building materials exposure to standardized conditions. The results of the chemical and sensory assessment of individual materials and their combinations are compared and discussed within the paper. The using possibility of individual material surface sorption ability was investigated. The knowledge of targeted sorption effects can be used in the interior design phase. The results demonstrate the various sorption abilities of various indoor materials as well as the various sorption abilities of the same indoor material in various combinations. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Potential exposures associated with indoor marijuana growing operations.

    PubMed

    Martyny, John W; Serrano, Kate A; Schaeffer, Joshua W; Van Dyke, Mike V

    2013-01-01

    We entered a total of 30 indoor marijuana grow operations (IMGO) with law enforcement investigators in order to determine potential exposures to first responders. Samples for airborne fungal spores, volatile organic compounds, carbon dioxide, carbon monoxide, and delta-9-tetrahydrocannabinol (THC) were obtained as well as the identification of chemicals utilized in the IMGO. The chemicals utilized within the IMGOs were primarily pesticides and fertilizers with none showing high toxicity. Although several of the IMGOs had CO2 enrichment processes involving combustion, CO levels were not elevated. THC levels were identified on surfaces within the IMGOs and on the hands of the investigators. Surface levels ranged from <0.1 μg /100 cm(2) to 2000 μg /100 cm(2) with a geometric mean of 0.37 μg /100 cm(2). THC levels on the hands of officers ranged from <0.10 μg /wipe to 2900 μg /wipe with a geometric mean of 15 μg /wipe. These levels were not considered to be elevated to the point of causing a toxic exposure to responders. A total of 407 fungal spore samples were taken using both slit impactor plates and 400-hole impactors. Both methods identified elevated fungal spore levels, especially during the removal of plants from some of the IMGOs. After plant removal, spore counts increased to levels above 50,000 spores/m(3) with one sample over 500,000 spores/m(3). In addition, we found that there was a shift in species between indoor and outdoor samples with Cladosporium sp. the predominant outdoor species and Penicillium sp. the predominant indoor species. We concluded that the potential increase in fungal spore concentrations associated with the investigation and especially removal of the marijuana plants could potentially expose responders to levels of exposure consistent with those associated with mold remediation processes and that respiratory protection is advisable.

  20. DISTRIBUTION OF 2,4-D IN AIR AND ON SURFACES INSIDE RESIDENCES FOLLOWING LAWN APPLICATIONS: COMPARING EXPOSURE ESTIMATES FOR YOUNG CHILDREN FROM VARIOUS MEDIA

    EPA Science Inventory

    Indoor air, surface wipes (floors, table tops and window sills) and floor dust samples were collected at multiple locations within 11 occupied and 2 unoccupied homes both prior to and following lawn application of the herbicide 2,4-D. Residue measurements were made over period...

  1. Short-term dynamics of indoor and outdoor endotoxin exposure: Case of Santiago, Chile, 2012.

    PubMed

    Barraza, Francisco; Jorquera, Héctor; Heyer, Johanna; Palma, Wilfredo; Edwards, Ana María; Muñoz, Marcelo; Valdivia, Gonzalo; Montoya, Lupita D

    2016-01-01

    Indoor and outdoor endotoxin in PM2.5 was measured for the very first time in Santiago, Chile, in spring 2012. Average endotoxin concentrations were 0.099 and 0.094 [EU/m(3)] for indoor (N=44) and outdoor (N=41) samples, respectively; the indoor-outdoor correlation (log-transformed concentrations) was low: R=-0.06, 95% CI: (-0.35 to 0.24), likely owing to outdoor spatial variability. A linear regression model explained 68% of variability in outdoor endotoxins, using as predictors elemental carbon (a proxy of traffic emissions), chlorine (a tracer of marine air masses reaching the city) and relative humidity (a modulator of surface emissions of dust, vegetation and garbage debris). In this study, for the first time a potential source contribution function (PSCF) was applied to outdoor endotoxin measurements. Wind trajectory analysis identified upwind agricultural sources as contributors to the short-term, outdoor endotoxin variability. Our results confirm an association between combustion particles from traffic and outdoor endotoxin concentrations. For indoor endotoxins, a predictive model was developed but it only explained 44% of endotoxin variability; the significant predictors were tracers of indoor PM2.5 dust (Si, Ca), number of external windows and number of hours with internal doors open. Results suggest that short-term indoor endotoxin variability may be driven by household dust/garbage production and handling. This would explain the modest predictive performance of published models that use answers to household surveys as predictors. One feasible alternative is to increase the sampling period so that household features would arise as significant predictors of long-term airborne endotoxin levels. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Human exposure to HBCD and TBBPA via indoor dust in Korea: Estimation of external exposure and body burden.

    PubMed

    Barghi, Mandana; Shin, Eun-Su; Kim, Jong-Chul; Choi, Sung-Deuk; Chang, Yoon-Seok

    2017-09-01

    Human exposure to brominated flame retardants (BFRs) such as hexabromocyclododecane (HBCD) and tetrabromobisphenol A (TBBPA) mainly occurs through diet and dust ingestion. In this study, the BFR concentrations in 124 vacuum dust samples of six categories of indoor environments (homes, offices, kindergartens, cars, schools, and public indoor environments) and 32 surface dust samples were investigated. The median ΣHBCD concentrations ranged from 106.30ngg -1 in home dust to 496.13ngg -1 in office dust. The TBBPA concentrations in indoor dust (from 78.87 to 463.81ngg -1 ) were among the highest compared to other countries because of the high market demand for this flame retardant in Korea. The TBBPA concentrations in surface dust of living rooms were significantly higher (p<0.05) than sleeping rooms, due to the presence of more electrical equipment in living rooms. The estimated daily intakes (EDI) of ΣHBCD and TBBPA (dust+diet) for toddlers were 6.18ngkg -1 bwd -1 and 2.54ngkg -1 bwd -1 , respectively. In general, the ΣHBCD estimated body burden of Korean adults showed good agreement with the reported ΣHBCD median concentrations in their sera. Since the developmental health effect of exposure to HBCD was categorized as "high hazard" by the US Environmental Protection Agency, the estimated high body burden of ΣHBCD in Korean toddlers (7.91ngg -1 lw) warns us of possible adverse effects on the development of essential systems in their bodies. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Children’s Exposure to Secondhand and Thirdhand Smoke Carcinogens and Toxicants in Homes of Hookah Smokers

    PubMed Central

    Daffa, Reem M.; Liles, Sandy; Jackson, Sheila R.; Kassem, Noura O.; Younis, Maram A.; Mehta, Setoo; Chen, Menglan; Jacob, Peyton; Carmella, Steve G.; Chatfield, Dale A.; Benowitz, Neal L.; Matt, Georg E.; Hecht, Stephen S.; Hovell, Melbourne F.

    2014-01-01

    Introduction: We examined homes of hookah-only smokers and nonsmokers for levels of indoor air nicotine (a marker of secondhand smoke) and indoor surface nicotine (a marker of thirdhand smoke), child uptake of nicotine, the carcinogen 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), and the toxicant acrolein by analyzing their corresponding metabolites cotinine, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) and NNAL-glucuronides (total NNAL) and 3-hydroxypropylmercapturic acid. Methods: Data were collected at 3 home visits during a 7-day study period from a convenience sample of 24 households with a child 5 years or younger. Three child urine samples and 2 air and surface samples from the living room and the child bedroom were taken in homes of nonsmokers (n = 5) and hookah-only smokers (n = 19) comprised of daily hookah smokers (n = 8) and weekly/monthly hookah smokers (n = 11). Results: Nicotine levels in indoor air and on surfaces in the child bedrooms in homes of daily hookah smokers were significantly higher than in homes of nonsmokers. Uptake of nicotine, NNK, and acrolein in children living in daily hookah smoker homes was significantly higher than in children living in nonsmoker homes. Uptake of nicotine and NNK in children living in weekly/monthly hookah smoker homes was significantly higher than in children living in nonsmoker homes. Conclusions: Our data provide the first evidence for uptake of nicotine, the tobacco-specific lung carcinogen NNK, and the ciliatoxic and cardiotoxic agent acrolein in children living in homes of hookah smokers. Our findings suggest that daily and occasional hookah use in homes present a serious, emerging threat to children’s long-term health. PMID:24590387

  4. Comparison of indoor air sampling and dust collection methods for fungal exposure assessment using quantitative PCR

    EPA Science Inventory

    Evaluating fungal contamination indoors is complicated because of the many different sampling methods utilized. In this study, fungal contamination was evaluated using five sampling methods and four matrices for results. The five sampling methods were a 48 hour indoor air sample ...

  5. Interaction of ozone with wooden building products, treated wood samples and exotic wood species

    NASA Astrophysics Data System (ADS)

    Schripp, Tobias; Langer, Sarka; Salthammer, Tunga

    2012-07-01

    Wooden building products indoors are known to be able to affect the perceived air quality depending on their emission strength. The indoor application of modern ecological lacquer systems (eco-lacquers or 'green' lacquers) may be a much stronger source than the substrates itself. Especially with regard to the formation of ultrafine particles by gas-to-particle conversion in the presence of ozone or other reactive species the impact of the applied building products on the indoor air quality has to be addressed. The present study reports a two concentration step ozonation of OSB panels, painted beech boards, and a number of solid 'exotic' wood types in a 1 m³ emission test chamber. The emission of volatile organic compounds (VOC) was recorded as well as the formation of ultrafine particles in the range 7-300 nm. The products are characterized on the basis of their ozone deposition velocity; the obtained values of 0.008-0.381 cm s-1 are comparable with previously published data. Within the samples of the present study one eco-lacquer was the strongest source of VOC (total VOC ˜ 60 mg m-3) while the wooden building products (OSB) were of intermediate emission strength. The lowest emission was found for the solid (exotic) wood samples. The VOC release of the samples corresponded roughly to the particle formation potential. However, the strongest UFP formation was measured for one solid wood sample ('Garapa') which showed a strong surface reaction in the presence of ozone and formed a large number of particles <40 nm. Overall, the experiments demonstrated the necessity of real-life samples for the estimation of UFP indoor air pollution from the ozone chemistry of terpenes.

  6. Effect of gaseous ammonia on nicotine sorption

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Webb, A.M.; Singer, B.C.; Nazaroff, W.W.

    2002-06-01

    Nicotine is a major constituent of environmental tobacco smoke. Sorptive interactions of nicotine with indoor surfaces can substantially alter indoor concentrations. The phenomenon is poorly understood, including whether sorption is fully reversible or partially irreversible. They hypothesize that acid-base chemistry on indoor surfaces might contribute to the apparent irreversibility of nicotine sorption under some circumstances. Specifically, they suggest that nicotine may become protonated on surfaces, markedly reducing its vapor pressure. If so, subsequent exposure of the surface to gaseous ammonia, a common base, could raise the surface pH, causing deprotonation and desorption of nicotine from surfaces. A series of experimentsmore » was conducted to explore the effect of ammonia on nicotine sorption to and reemission from surfaces. The results indicate that, under some conditions, exposure to gaseous ammonia can substantially increase the rate of desorption of previously sorbed nicotine from common indoor surface materials.« less

  7. Chemical mechanisms of photocatalytic de-soiling and de-polluting processes in indoor environments and urban surfaces

    NASA Astrophysics Data System (ADS)

    Sleiman, M.; Rosseler, O.; Montesinos, N.; Litter, M.; Bikiel, D.; Kirchstetter, T.; Bluhm, H.; Ahmed, M.; Salmeron, M.; Destaillats, H.

    2013-12-01

    Photocatalysis has been postulated as a promising approach for the de-pollution of indoor air and urban atmospheres, and for self-cleaning surfaces. Building materials and coatings containing nano-sized TiO2 photocatalytic functionalities are gaining market share, including self-cleaning building envelope materials (coatings, mortar, plaster, architectural fabrics and tiles) and indoor air purifiers. While many studies have reported good performance of photocatalysis in the removal of organic pollutants from indoor air, more information is needed to understand secondary emissions of potentially harmful byproducts from photocatalytic air cleaners. This presentation will describe analytical methods and experimental results from room-sized chamber experiments using a realistic challenge VOC mixture at low ppb levels. We will also present results from separate studies that used synchrotron-based surface spectroscopic and mass spectrometric methods to better understand the photocatalytic mechanisms that regulate the de-soiling and de-polluting activity. Two photocatalytic processes were studied: de-noxification (NOx removal) and de-soiling (removal of deposited black carbon or soot). Ambient pressure XPS was used to study surface and gas-phase species formed during adsorption of NO2 on TiO2 and subsequent UV irradiation at λ = 365 nm. The results illustrate how NOx chemistry on TiO2 surfaces can be affected by the presence of water vapor, heteroatoms present as impurities, and carbonaceous soiling. The reactivity of NOx and NO3- on surfaces leads to reduced adsorbed and gas-phase nitrogenated species. These processes need to be considered in the engineering of depolluting materials and incorporated into atmospheric models. De-soiling properties were investigated by analyzing soot oxidation on TiO2 surfaces. Model soot samples were used as surrogates of urban grime. Using laser desorption coupled with time-of-flight (TOF) mass spectrometry synchrotron ionization, we investigated the mechanisms of photocatalytic soot removal under UVA irradiation. Ancillary reflectance measurements were performed to determine the efficiency and kinetics of soot removal.

  8. COMPARING PESTICIDE TRANSFERS FROM RESIDENTIAL SURFACE USING TRANSFERABLE RESIDUE SAMPLING TECHNIQUES AND VIDEO-FLUORESCENT IMAGING

    EPA Science Inventory

    The recent change from organophosphate (OP) to pyrethroid insecticides for indoor residential pest control may significantly affect the relative importance of different exposure routes because of differences in physical/chemical properties of these two classes of compounds. In...

  9. Polycyclic aromatic hydrocarbons and their derivatives in indoor and outdoor air in an eight-home study

    NASA Astrophysics Data System (ADS)

    Chuang, Jane C.; Mack, Gregory A.; Kuhlman, Michael R.; Wilson, Nancy K.

    A pilot field study was performed in Columbus, OH, during the winter of 1986/1987. The objectives were to determine the feasibility of the use of a newly developed quiet sampler in indoor air sampling for particles and semivolatile organic compounds (SVOC) and to measure the concentrations of polycyclic aromatic hydrocarbons (PAH), PAH derivatives, and nicotine in air in selected residences. Eight homes were chosen for sampling on the basis of these characteristics: electric/gas heating system, electric/gas cooking appliances, and the absence/presence of environmental tobacco smoke (ETS). The indoor sampler was equipped with a quartz-fiber filter to collect particles followed by XAD-4 resin to trap SVOC. A PS-1 sampler with a similar sampling module was used outdoors. The indoor air was sampled in the kitchen and living room areas over two consecutive 8-h periods. The outdoor air was sampled concurrently with the indoor samples over a 16-h period. Fifteen PAH, five nitro-PAH, five oxygenated PAH, and three nitrogen heterocyclic compounds were determined in these samples. The most abundant PAH found indoors was naphthalene. The indoor concentrations of PAH derivatives were lower than those of their parent compounds. Average concentrations of all but three target compounds (naphthalene dicarboxylic acid anhydride, pyrene dicarboxylic acid anhydride, and 2-nitrofluoranthene) were higher indoors than outdoors. Environmental tobacco smoke was the most significant influence on indoor pollutant levels. Homes with gas heating systems had higher indoor pollutant levels than homes with electric heating systems. However, the true effects of heating and cooking systems were not characterized as accurately as the effects of ETS because of the small sample sizes and the lack of statistical significance for most pollutant differences in the absence of ETS. The concentrations of PAH marker compounds (phenanthrene, fluoranthene, and pyrene) correlated well with the concentrations of other target compounds. Quinoline and isoquinoline can be used to indicate indoor levels of ETS.

  10. Sources of Propylene Glycol and Glycol Ethers in Air at Home

    PubMed Central

    Choi, Hyunok; Schmidbauer, Norbert; Spengler, John; Bornehag, Carl-Gustaf

    2010-01-01

    Propylene glycol and glycol ether (PGE) in indoor air have recently been associated with asthma and allergies as well as sensitization in children. In this follow-up report, sources of the PGEs in indoor air were investigated in 390 homes of pre-school age children in Sweden. Professional building inspectors examined each home for water damages, mold odour, building’s structural characteristics, indoor temperature, absolute humidity and air exchange rate. They also collected air and dust samples. The samples were analyzed for four groups of volatile organic compounds (VOCs) and semi-VOCs (SVOCs), including summed concentrations of 16 PGEs, 8 terpene hydrocarbons, 2 Texanols, and the phthalates n-butyl benzyl phthalate (BBzP), and di(2-ethylhexyl)phthalate (DEHP). Home cleaning with water and mop ≥ once/month, repainting ≥ one room prior to or following the child’s birth, and “newest” surface material in the child’s bedroom explained largest portion of total variability in PGE concentrations. High excess indoor humidity (g/m3) additionally contributed to a sustained PGE levels in indoor air far beyond several months following the paint application. No behavioral or building structural factors, except for water-based cleaning, predicted an elevated terpene level in air. No significant predictor of Texanols emerged from our analysis. Overall disparate sources and low correlations among the PGEs, terpenes, Texanols, and the phthalates further confirm the lack of confounding in the analysis reporting the associations of the PGE and the diagnoses of asthma, rhinitis, and eczema, respectively. PMID:21318004

  11. Sources of propylene glycol and glycol ethers in air at home.

    PubMed

    Choi, Hyunok; Schmidbauer, Norbert; Spengler, John; Bornehag, Carl-Gustaf

    2010-12-01

    Propylene glycol and glycol ether (PGE) in indoor air have recently been associated with asthma and allergies as well as sensitization in children. In this follow-up report, sources of the PGEs in indoor air were investigated in 390 homes of pre-school age children in Sweden. Professional building inspectors examined each home for water damages, mold odour, building's structural characteristics, indoor temperature, absolute humidity and air exchange rate. They also collected air and dust samples. The samples were analyzed for four groups of volatile organic compounds (VOCs) and semi-VOCs (SVOCs), including summed concentrations of 16 PGEs, 8 terpene hydrocarbons, 2 Texanols, and the phthalates n-butyl benzyl phthalate (BBzP), and di(2-ethylhexyl)phthalate (DEHP). Home cleaning with water and mop ≥ once/month, repainting ≥ one room prior to or following the child's birth, and "newest" surface material in the child's bedroom explained largest portion of total variability in PGE concentrations. High excess indoor humidity (g/m³) additionally contributed to a sustained PGE levels in indoor air far beyond several months following the paint application. No behavioral or building structural factors, except for water-based cleaning, predicted an elevated terpene level in air. No significant predictor of Texanols emerged from our analysis. Overall disparate sources and low correlations among the PGEs, terpenes, Texanols, and the phthalates further confirm the lack of confounding in the analysis reporting the associations of the PGE and the diagnoses of asthma, rhinitis, and eczema, respectively.

  12. Source Apportionment and Influencing Factor Analysis of Residential Indoor PM2.5 in Beijing

    PubMed Central

    Yang, Yibing; Liu, Liu; Xu, Chunyu; Li, Na; Liu, Zhe; Wang, Qin; Xu, Dongqun

    2018-01-01

    In order to identify the sources of indoor PM2.5 and to check which factors influence the concentration of indoor PM2.5 and chemical elements, indoor concentrations of PM2.5 and its related elements in residential houses in Beijing were explored. Indoor and outdoor PM2.5 samples that were monitored continuously for one week were collected. Indoor and outdoor concentrations of PM2.5 and 15 elements (Al, As, Ca, Cd, Cu, Fe, K, Mg, Mn, Na, Pb, Se, Tl, V, Zn) were calculated and compared. The median indoor concentration of PM2.5 was 57.64 μg/m3. For elements in indoor PM2.5, Cd and As may be sensitive to indoor smoking, Zn, Ca and Al may be related to indoor sources other than smoking, Pb, V and Se may mainly come from outdoor. Five factors were extracted for indoor PM2.5 by factor analysis, explained 76.8% of total variance, outdoor sources contributed more than indoor sources. Multiple linear regression analysis for indoor PM2.5, Cd and Pb was performed. Indoor PM2.5 was influenced by factors including outdoor PM2.5, smoking during sampling, outdoor temperature and time of air conditioner use. Indoor Cd was affected by factors including smoking during sampling, outdoor Cd and building age. Indoor Pb concentration was associated with factors including outdoor Pb and time of window open per day, building age and RH. In conclusion, indoor PM2.5 mainly comes from outdoor sources, and the contributions of indoor sources also cannot be ignored. Factors associated indoor and outdoor air exchange can influence the concentrations of indoor PM2.5 and its constituents. PMID:29621164

  13. Source Apportionment and Influencing Factor Analysis of Residential Indoor PM2.5 in Beijing.

    PubMed

    Yang, Yibing; Liu, Liu; Xu, Chunyu; Li, Na; Liu, Zhe; Wang, Qin; Xu, Dongqun

    2018-04-05

    In order to identify the sources of indoor PM 2.5 and to check which factors influence the concentration of indoor PM 2.5 and chemical elements, indoor concentrations of PM 2.5 and its related elements in residential houses in Beijing were explored. Indoor and outdoor PM 2.5 samples that were monitored continuously for one week were collected. Indoor and outdoor concentrations of PM 2.5 and 15 elements (Al, As, Ca, Cd, Cu, Fe, K, Mg, Mn, Na, Pb, Se, Tl, V, Zn) were calculated and compared. The median indoor concentration of PM 2.5 was 57.64 μg/m³. For elements in indoor PM 2.5 , Cd and As may be sensitive to indoor smoking, Zn, Ca and Al may be related to indoor sources other than smoking, Pb, V and Se may mainly come from outdoor. Five factors were extracted for indoor PM 2.5 by factor analysis, explained 76.8% of total variance, outdoor sources contributed more than indoor sources. Multiple linear regression analysis for indoor PM 2.5 , Cd and Pb was performed. Indoor PM 2.5 was influenced by factors including outdoor PM 2.5 , smoking during sampling, outdoor temperature and time of air conditioner use. Indoor Cd was affected by factors including smoking during sampling, outdoor Cd and building age. Indoor Pb concentration was associated with factors including outdoor Pb and time of window open per day, building age and RH. In conclusion, indoor PM 2.5 mainly comes from outdoor sources, and the contributions of indoor sources also cannot be ignored. Factors associated indoor and outdoor air exchange can influence the concentrations of indoor PM 2.5 and its constituents.

  14. Health hazard evaluation report HETA 90-168-2248, Independence Police Department Indoor Range, Independence, Missouri

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rinehart, R.D.; Almaguer, D.; Klein, M.K.

    1992-08-01

    On February 14, 1990, the National Institute for Occupational Safety and Health (NIOSH) received a request from a management representative of the Independence, Missouri, Police Department Headquarters for a Health Hazard Evaluation. The Police Department requested NIOSH to evaluate the effectiveness of a newly redesigned air handling system installed inside their indoor firing range. On August 6, 1991, NIOSH investigators met with the firing range supervisor and toured the facility. On August 8, ten personal breathing-zone (PBZ) air samples and 3 area air samples were collected on filters inside the range and the filters were subsequently analyzed for lead bymore » atomic absorption spectroscopy (AAS). Surface lead contamination inside the firing range was measured in two locations and hand (dermal) lead contamination was measured on two instructors and two field officers. These samples were also analyzed for lead by AAS.« less

  15. Investigation of the Persistence of Nerve Agent Degradation ...

    EPA Pesticide Factsheets

    Journal Article The persistence of chemical warfare nerve agent degradation analytes on surfaces is important for reasons ranging from indicating the presence of nerve agent on that surface to environmental restoration of a site after nerve agent release. This study investigates the persistence of several chemical warfare nerve agent degradation analytes on a number of indoor surfaces and presents an approach for wipe sampling of surfaces, followed by wipe extraction and liquid chromatography-tandem mass spectrometry detection. Multiple commercially available wipe materials were investigated to determine optimal wipe recoveries. Tested surfaces, including several porous/permeable and largely nonporous/impermeable surfaces, were investigated to determine recoveries from these indoor surface materials. Wipe extracts were analyzed by ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) and compared with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) results. UPLC provides a sensitive separation of targeted degradation analytes in addition to being nearly four times faster than HPLC, allowing for greater throughput during a widespread release concerning large-scale contamination and subsequent remediation events. Percent recoveries from nonporous/impermeable surfaces were 60-103% for isopropyl methylphosphonate (IMPA), 61-91 % for ethyl methylphosphonate (EMPA), and 60-98% for pinacolyl methylphosphona

  16. The effect of the indoor environment on the fate of organic chemicals in the urban landscape.

    PubMed

    Cousins, Anna Palm

    2012-11-01

    To assess the effect of the indoor environment on the urban fate of organic chemicals, an 8-compartment indoor-inclusive steady state multimedia chemical fate model was developed. The model includes typical urban compartments (air, soil, water, sediment, and urban film) and a novel module representing a generic indoor environment. The model was parameterized to the municipality of Stockholm, Sweden and applied to four organic chemicals with different physical-chemical characteristics and use patterns: formaldehyde, 2,4,6-tribromophenol, di-ethylhexylphthalate and decabromodiphenyl ether. The results show that emissions to indoor air may increase the steady state mass and residence time in the urban environment by a factor of 1.1 to 22 for the four chemicals, compared to if emissions are assigned to outdoor air. This is due to the nested nature of the indoor environment, which creates a physical barrier that prevents chemicals from leaving the urban system with outflowing air. For DEHP and BDE 209, the additional partitioning to indoor surfaces results in a greater importance of the indoor removal pathways from surfaces. The outdoor environmental concentrations of these chemicals are predicted to be lower if emitted to indoor air than if emitted to outdoor air because of the additional indoor removal pathways of dust and indoor film, leading to loss of chemical from the system. For formaldehyde and 2,4,6-TBP outdoor environmental concentrations are not affected by whether the release occurs indoors or outdoors because of the limited partitioning to indoor surfaces. A sensitivity analysis revealed that there appears to be a relationship between logK(OA) and the impact of the ventilation rate on the urban fate of organic chemicals. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Evaluation of a standardized micro-vacuum sampling method for collection of surface dust.

    PubMed

    Ashley, Kevin; Applegate, Gregory T; Wise, Tamara J; Fernback, Joseph E; Goldcamp, Michael J

    2007-03-01

    A standardized procedure for collecting dust samples from surfaces using a micro-vacuum sampling technique was evaluated. Experiments were carried out to investigate the collection efficiency of the vacuum sampling method described in ASTM Standard D7144, "Standard Practice for Collection of Surface Dust by Micro-Vacuum Sampling for Subsequent Metals Determination." Weighed masses ( approximately 5, approximately 10 and approximately 25 mg) of three NIST Standard Reference Materials (SRMs) were spiked onto surfaces of various substrates. The SRMs used were: (1) Powdered Lead-Based Paint; (2) Urban Particulate Matter; and (3) Trace Elements in Indoor Dust. Twelve different substrate materials were chosen to be representative of surfaces commonly encountered in occupational and/or indoor settings: (1) wood, (2) tile, (3) linoleum, (4) vinyl, (5) industrial carpet, (6) plush carpet, (7,8) concrete block (painted and unpainted), (9) car seat material, (10) denim, (11) steel, and (12) glass. Samples of SRMs originally spiked onto these surfaces were collected using the standardized micro-vacuum sampling procedure. Gravimetric analysis of material collected within preweighed Accucapinserts (housed within the samplers) was used to measure SRM recoveries. Recoveries ranged from 21.6% (+/- 10.4%, 95% confidence limit [CL]) for SRM 1579 from industrial carpet to 59.2% (+/- 11.0%, 95% CL) for SRM 1579 from glass. For most SRM/substrate combinations, recoveries ranged from approximately 25% to approximately 50%; variabilities differed appreciably. In general, SRM recoveries were higher from smooth and hard surfaces and lower from rough and porous surfaces. Material captured within collection nozzles attached to the sampler inlets was also weighed. A significant fraction of SRM originally spiked onto substrate surfaces was captured within collection nozzles. Percentages of SRMs captured within collection nozzles ranged from approximately 13% (+/- 4 - +/- 5%, 95% CLs) for SRMs 1579 and 2583 from industrial carpet to approximately 45% (+/- 7 - +/- 26%, 95% CLs) for SRM 1648 from glass, tile and steel. For some substrates, loose material from the substrate itself (i.e., substrate particles and fibers) was sometimes collected along with the SRM, both within Accucaps as well as collection nozzles. Co-collection of substrate material can bias results and contribute to sampling variability. The results of this work have provided performance data on the standardized micro-vacuum sampling procedure.

  18. Soil radium, soil gas radon and indoor radon empirical relationships to assist in post-closure impact assessment related to near-surface radioactive waste disposal.

    PubMed

    Appleton, J D; Cave, M R; Miles, J C H; Sumerling, T J

    2011-03-01

    Least squares (LS), Theil's (TS) and weighted total least squares (WTLS) regression analysis methods are used to develop empirical relationships between radium in the ground, radon in soil and radon in dwellings to assist in the post-closure assessment of indoor radon related to near-surface radioactive waste disposal at the Low Level Waste Repository in England. The data sets used are (i) estimated ²²⁶Ra in the < 2 mm fraction of topsoils (eRa226) derived from equivalent uranium (eU) from airborne gamma spectrometry data, (ii) eRa226 derived from measurements of uranium in soil geochemical samples, (iii) soil gas radon and (iv) indoor radon data. For models comparing indoor radon and (i) eRa226 derived from airborne eU data and (ii) soil gas radon data, some of the geological groupings have significant slopes. For these groupings there is reasonable agreement in slope and intercept between the three regression analysis methods (LS, TS and WTLS). Relationships between radon in dwellings and radium in the ground or radon in soil differ depending on the characteristics of the underlying geological units, with more permeable units having steeper slopes and higher indoor radon concentrations for a given radium or soil gas radon concentration in the ground. The regression models comparing indoor radon with soil gas radon have intercepts close to 5 Bq m⁻³ whilst the intercepts for those comparing indoor radon with eRa226 from airborne eU vary from about 20 Bq m⁻³ for a moderately permeable geological unit to about 40 Bq m⁻³ for highly permeable limestone, implying unrealistically high contributions to indoor radon from sources other than the ground. An intercept value of 5 Bq m⁻³ is assumed as an appropriate mean value for the UK for sources of indoor radon other than radon from the ground, based on examination of UK data. Comparison with published data used to derive an average indoor radon: soil ²²⁶Ra ratio shows that whereas the published data are generally clustered with no obvious correlation, the data from this study have substantially different relationships depending largely on the permeability of the underlying geology. Models for the relatively impermeable geological units plot parallel to the average indoor radon: soil ²²⁶Ra model but with lower indoor radon: soil ²²⁶Ra ratios, whilst the models for the permeable geological units plot parallel to the average indoor radon: soil ²²⁶Ra model but with higher than average indoor radon: soil ²²⁶Ra ratios. Copyright © 2010 Natural Environment Research Council. Published by Elsevier Ltd.. All rights reserved.

  19. Light-induced heterogeneous reactions of NO2 on indoor surfaces: How they affect the balance of nitrous acid

    NASA Astrophysics Data System (ADS)

    Gomez Alvarez, E.; Soergel, M.; Bassil, S.; Zetzsch, C.; Gligorovski, S.; Wortham, H.

    2011-12-01

    Nitrous acid (HONO) is an important indoor pollutant. The adverse health effects due to the formation of nitrosamines are well known. HONO acts as a nitrosating agent after wall reactions of HONO with nicotine [Sleiman et al., 2010]. Indoor air can be surprisingly rich in HONO (homes with fireplaces, stoves, gas heating and cooking) and also surfaces are abundant. High HONO concentrations have been measured in indoor environments, from the direct emissions and heterogeneous reactions of NO2 in darkness. However, the measured HONO concentrations do not correspond to the HONO levels determined by the models [Carslaw, 2007]. We have tested in a flow tube reactor on-line coupled to a NOx analyzer and a sensitive Long Path Absorption Photometry instrument, the behaviour of various indoor surfaces towards NO2 under simulated solar light irradiation (λ= 300-700 nm). Our study has allowed us to obtain a deeper knowledge on the mechanisms of heterogeneous formation of HONO, quantifying the dependence of HONO formation on behalf of NO2 concentration and relative humidity and the enhancement of HONO formation in the presence of light. Pyrex, acidic detergent, alkaline detergent, paint and lacquer were tested on behalf of their heterogeneous reactivity towards NO2 in the absence and in presence of light. The results obtained demonstrated that indoor surfaces are photo-chemically active under atmospherically relevant conditions. The strongly alkaline surfaces (such as certain types of detergent) show a strong long-term uptake capacity. However, other surfaces such as detergents with a more acidic character released HONO. In some cases such as paint and varnish, a strong HONO release with light was detected, which was significantly higher than that obtained over clean glass surfaces. Certain organics present on their composition could exert a photo-sensitizing effect that may explain their increased reactivity. Unfortunately, the final balance points towards an important net production of HONO from organics usually applied on different indoor surfaces that add to the very powerful HONO production simply due to heterogeneous reactivity on bare indoor surfaces. The results of this study add to the increasing concern over the reactivity in indoor environments and in particular from the point of view of HONO formation kinetics.

  20. Polybrominated diphenyl ether (PBDE) concentrations and resulting exposure in homes in California: relationships among passive air, surface wipe and dust concentrations, and temporal variability

    PubMed Central

    Bennett, D. H.; Moran, R. E.; Wu, X. (May); Tulve, N. S.; Clifton, M. S.; Colón, M.; Weathers, W.; Sjödin, A.; Jones, R.; Hertz-Picciotto, I.

    2016-01-01

    Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive air, floor and indoor window surface wipes, and dust samples (investigator collected using an HVS3 and vacuum cleaner) in each home. PentaBDE and BDE209 were detected in the majority of the dust samples and many floor wipe samples, but the detection in air and window wipe samples was relatively low. Concentrations of each PBDE congener in different indoor environmental media were moderately correlated, with correlation coefficients ranging between 0.42 and 0.68. Correlation coefficients with blood levels were up to 0.65 and varied between environmental media and age group. Both investigator-collected dust and floor wipes were correlated with serum levels for a wide range of congeners. These two sample types also had a relatively high fraction of samples with adequate mass for reliable quantification. In 42 homes, PBDE levels measured in the same environmental media in the same home 1 year apart were statistically correlated (correlation coefficients: 0.57–0.90), with the exception of BDE209 which was not well correlated longitudinally. PMID:24832910

  1. Geography and Location Are the Primary Drivers of Office Microbiome Composition

    PubMed Central

    Chase, John; Fouquier, Jennifer; Zare, Mahnaz; Sonderegger, Derek L.; Knight, Rob; Kelley, Scott T.; Siegel, Jeffrey

    2016-01-01

    ABSTRACT In the United States, humans spend the majority of their time indoors, where they are exposed to the microbiome of the built environment (BE) they inhabit. Despite the ubiquity of microbes in BEs and their potential impacts on health and building materials, basic questions about the microbiology of these environments remain unanswered. We present a study on the impacts of geography, material type, human interaction, location in a room, seasonal variation, and indoor and microenvironmental parameters on bacterial communities in offices. Our data elucidate several important features of microbial communities in BEs. First, under normal office environmental conditions, bacterial communities do not differ on the basis of surface material (e.g., ceiling tile or carpet) but do differ on the basis of the location in a room (e.g., ceiling or floor), two features that are often conflated but that we are able to separate here. We suspect that previous work showing differences in bacterial composition with surface material was likely detecting differences based on different usage patterns. Next, we find that offices have city-specific bacterial communities, such that we can accurately predict which city an office microbiome sample is derived from, but office-specific bacterial communities are less apparent. This differs from previous work, which has suggested office-specific compositions of bacterial communities. We again suspect that the difference from prior work arises from different usage patterns. As has been previously shown, we observe that human skin contributes heavily to the composition of BE surfaces. IMPORTANCE Our study highlights several points that should impact the design of future studies of the microbiology of BEs. First, projects tracking changes in BE bacterial communities should focus sampling efforts on surveying different locations in offices and in different cities but not necessarily different materials or different offices in the same city. Next, disturbance due to repeated sampling, though detectable, is small compared to that due to other variables, opening up a range of longitudinal study designs in the BE. Next, studies requiring more samples than can be sequenced on a single sequencing run (which is increasingly common) must control for run effects by including some of the same samples in all of the sequencing runs as technical replicates. Finally, detailed tracking of indoor and material environment covariates is likely not essential for BE microbiome studies, as the normal range of indoor environmental conditions is likely not large enough to impact bacterial communities. PMID:27822521

  2. Ozone reaction with interior building materials: Influence of diurnal ozone variation, temperature and humidity

    NASA Astrophysics Data System (ADS)

    Rim, Donghyun; Gall, Elliott T.; Maddalena, Randy L.; Nazaroff, William W.

    2016-01-01

    Elevated tropospheric ozone concentrations are associated with increased morbidity and mortality. Indoor ozone chemistry affects human exposure to ozone and reaction products that also may adversely affect health and comfort. Reactive uptake of ozone has been characterized for many building materials; however, scant information is available on how diurnal variation of ambient ozone influences ozone reaction with indoor surfaces. The primary objective of this study is to investigate ozone-surface reactions in response to a diurnally varying ozone exposure for three common building materials: ceiling tile, painted drywall, and carpet tile. A secondary objective is to examine the effects of air temperature and humidity. A third goal is to explore how conditioning of materials in an occupied office building might influence subsequent ozone-surface reactions. Experiments were performed at bench-scale with inlet ozone concentrations varied to simulate daytime (ozone elevated) and nighttime (ozone-free in these experiments) periods. To simulate office conditions, experiments were conducted at two temperatures (22 °C and 28 °C) and three relative humidity values (25%, 50%, 75%). Effects of indoor surface exposures were examined by placing material samples in an occupied office and repeating bench-scale characterization after exposure periods of 1 and 2 months. Deposition velocities were observed to be highest during the initial hour of ozone exposure with slow decrease in the subsequent hours of simulated daytime conditions. Daily-average ozone reaction probabilities for fresh materials are in the respective ranges of (1.7-2.7) × 10-5, (2.8-4.7) × 10-5, and (3.0-4.5) × 10-5 for ceiling tile, painted drywall, and carpet tile. The reaction probability decreases by 7%-47% across the three test materials after two 8-h periods of ozone exposure. Measurements with the samples from an occupied office reveal that deposition velocity can decrease or increase with time. Influence of temperature and humidity on ozone-surface reactivity was not strong.

  3. DETERMINATION OF PARTICLE DEPOSITION RATES FOR COOKING AND OTHER INDOOR SOURCE

    EPA Science Inventory

    Residential indoor particle concentrations are dependent on indoor sources, penetration of outdoor particles, air change with outdoors, and deposition of particles on indoor surfaces as well as other loss mechanisms. Of these factors, few data are available on deposition of pa...

  4. VOC source identification from personal and residential indoor, outdoor and workplace microenvironment samples in EXPOLIS-Helsinki, Finland

    NASA Astrophysics Data System (ADS)

    Edwards, Rufus D.; Jurvelin, J.; Koistinen, K.; Saarela, K.; Jantunen, M.

    Principal component analyses (varimax rotation) were used to identify common sources of 30 target volatile organic compounds (VOCs) in residential outdoor, residential indoor and workplace microenvironment and personal 48-h exposure samples, as a component of the EXPOLIS-Helsinki study. Variability in VOC concentrations in residential outdoor microenvironments was dominated by compounds associated with long-range transport of pollutants, followed by traffic emissions, emissions from trees and product emissions. Variability in VOC concentrations in environmental tobacco smoke (ETS) free residential indoor environments was dominated by compounds associated with indoor cleaning products, followed by compounds associated with traffic emissions, long-range transport of pollutants and product emissions. Median indoor/outdoor ratios for compounds typically associated with traffic emissions and long-range transport of pollutants exceeded 1, in some cases quite considerably, indicating substantial indoor source contributions. Changes in the median indoor/outdoor ratios during different seasons reflected different seasonal ventilation patterns as increased ventilation led to dilution of those VOC compounds in the indoor environment that had indoor sources. Variability in workplace VOC concentrations was dominated by compounds associated with traffic emissions followed by product emissions, long-range transport and air fresheners. Variability in VOC concentrations in ETS free personal exposure samples was dominated by compounds associated with traffic emissions, followed by long-range transport, cleaning products and product emissions. VOC sources in personal exposure samples reflected the times spent in different microenvironments, and personal exposure samples were not adequately represented by any one microenvironment, demonstrating the need for personal exposure sampling.

  5. Adsorption of Phthalates on Impervious Indoor Surfaces.

    PubMed

    Wu, Yaoxing; Eichler, Clara M A; Leng, Weinan; Cox, Steven S; Marr, Linsey C; Little, John C

    2017-03-07

    Sorption of semivolatile organic compounds (SVOCs) onto interior surfaces, often referred to as the "sink effect", and their subsequent re-emission significantly affect the fate and transport of indoor SVOCs and the resulting human exposure. Unfortunately, experimental challenges and the large number of SVOC/surface combinations have impeded progress in understanding sorption of SVOCs on indoor surfaces. An experimental approach based on a diffusion model was thus developed to determine the surface/air partition coefficient K of di-2-ethylhexyl phthalate (DEHP) on typical impervious surfaces including aluminum, steel, glass, and acrylic. The results indicate that surface roughness plays an important role in the adsorption process. Although larger data sets are needed, the ability to predict K could be greatly improved by establishing the nature of the relationship between surface roughness and K for clean indoor surfaces. Furthermore, different surfaces exhibit nearly identical K values after being exposed to kitchen grime with values that are close to those reported for the octanol/air partition coefficient. This strongly supports the idea that interactions between gas-phase DEHP and soiled surfaces have been reduced to interactions with an organic film. Collectively, the results provide an improved understanding of equilibrium partitioning of SVOCs on impervious surfaces.

  6. Associations between PBDEs in Office Air, Dust, and Surface Wipes

    PubMed Central

    Watkins, Deborah J.; McClean, Michael D.; Fraser, Alicia J.; Weinberg, Janice; Stapleton, Heather M.; Webster, Thomas F.

    2013-01-01

    Increased use of flame-retardants in office furniture may increase exposure to PBDEs in the office environment. However, partitioning of PBDEs within the office environment is not well understood. Our objectives were to examine relationships between concurrent measures of PBDEs in office air, floor dust, and surface wipes. We collected air, dust, and surface wipe samples from 31 offices in Boston, MA. Correlation and linear regression were used to evaluate associations between variables. Geometric mean (GM) concentrations of individual BDE congeners in air and congener specific octanol-air partition coefficients (Koa) were used to predict GM concentrations in dust and surface wipes and compared to the measured concentrations. GM concentrations of PentaBDEs in office air, dust, and surface wipes were 472 pg/m3, 2411 ng/g, and 77 pg/cm2, respectively. BDE209 was detected in 100% of dust samples (GM=4202 ng/g), 93% of surface wipes (GM=125 pg/cm2), and 39% of air samples. PentaBDEs in dust and air were moderately correlated with each other (r=0.60, p=0.0003), as well as with PentaBDEs in surface wipes (r=0.51, p=0.003 for both dust and air). BDE209 in dust was correlated with BDE209 in surface wipes (r=0.69, p=0.007). Building (three categories) and PentaBDEs in dust were independent predictors of PentaBDEs in both air and surface wipes, together explaining 50% (p=0.0009) and 48% (p=0.001) of the variation respectively. Predicted and measured concentrations of individual BDE congeners were highly correlated in dust (r=0.98, p<0.0001) and surface wipes (r=0.94, p=002). BDE209 provided an interesting test of this equilibrium partitioning model as it is a low volatility compound. Associations between PentaBDEs in multiple sampling media suggest that collecting dust or surface wipes may be a convenient method of characterizing exposure in the indoor environment. The volatility of individual congeners, as well as physical characteristics of the indoor environment, influence relationships between PBDEs in air, dust, and surface wipes. PMID:23797055

  7. Indoor air quality in Latino homes in Boulder, Colorado

    NASA Astrophysics Data System (ADS)

    Escobedo, Luis E.; Champion, Wyatt M.; Li, Ning; Montoya, Lupita D.

    2014-08-01

    Indoor concentrations of airborne pollutants can be several times higher than those found outdoors, often due to poor ventilation, overcrowding, and the contribution of indoor sources within a home. Americans spend most of their time indoors where exposure to poor indoor air quality (IAQ) can result in diminished respiratory and cardiovascular health. This study measured the indoor air quality in 30 homes of a low-income Latino community in Boulder, Colorado during the summer of 2012. Participants were administered a survey, which included questions on their health conditions and indoor air pollution sources like cigarette smoke, heating fuel, and building materials. Twenty-four hour samples of fine particulate matter (PM2.5) from the indoor air were collected in each home; ambient PM2.5 samples were collected each day as well. Concurrent air samples were collected onto 47 mm Teflo and Tissuquartz filter at each location. Teflo filters were analyzed gravimetrically to measure PM2.5 and their extracts were used to determine levels of proteins and endotoxins in the fine fraction. The Tissuquartz filters were analyzed for elemental and organic carbon content (EC/OC). Results indicated that the indoor air contained higher concentrations of PM2.5 than the ambient air, and that the levels of OC were much higher than EC in both indoor and outdoor samples. This community showed no smoking in their homes and kept furry pets indoors at very low rates; therefore, cooking is likely the primary source of indoor PM. For responders with significant exposure to PM, it appeared to be primarily from occupational environments or childhood exposure abroad. Our findings indicate that for immigrant communities such as this, it is important to consider not only their housing conditions but also the relevant prior exposures when conducting health assessments.

  8. Variation of airborne bacteria and fungi at Emperor Qin's Terra-Cotta Museum, Xi'an, China, during the "Oct. 1" gold week period of 2006.

    PubMed

    Chen, Yi-Ping; Cui, Ying; Dong, Jun-Gang

    2010-02-01

    To stimulate the national economy, a so-called "gold week" comprising May Day and National Day has been put in force by the government, and the first golden-week holiday began on October 1, 1999. Statistical data show that about 15,000 visitors were received each day by Emperor Qin's Terra-Cotta Museum during just such a gold week period. To evaluate the effects of tourism on indoor air, airborne samples were collected by the sedimentation plate method for 5 min during the "Oct. 1" gold week period of 2006, and both composition and changes of airborne bacteria and fungi in indoor/outdoor air in the museums were investigated. Airborne microbes were simultaneously collected by means of gravitational sedimentation on open Petri dishes. Three parallel samples were collected at the same time each day, and samples were subsequently incubated in the lab. Microbiology media were prepared before each experiment by a professional laboratory. Concentrations were calculated and presented as average data of colony-forming units per cubic meter of air (CFU/m(3)). The results show that (1) 13 bacterial genera and eight genera of fungi were identified from indoor and outdoor air at Emperor Qin's Terra-Cotta Museum during "Oct. 1" gold week in 2006. The bacterial groups occupied 61%, the fungi groups occupied 36%, and others occupied 3% of the total number of isolated microorganism genera. (2) As for the comparison of indoor and outdoor samples, the average concentrations of fungi were higher during the afternoon (13:00) than for the morning (09:00). The average concentrations of bacteria in indoor air were higher during the afternoon (13:00) than for the morning (9:00), and in outdoor air, they were lower during the afternoon (13:00) than for the morning (9:00). (3) The average concentrations of five dominant groups of bacteria and three dominant groups of fungi were higher during the afternoon (13:00) than for the morning (9:00) in the indoor air, but the average concentrations of fungi were higher and those of bacteria were lower during the afternoon than for the morning, for outdoor air. (4) As for the comparison of indoor samples, the bacterial daily concentrations and fungal daily concentrations were higher during the afternoon (13:00) than those for the mornings (9:00) over the 10 days. For the comparison of outdoor samples, the bacterial concentration was lower, and the fungal concentrations were higher during the afternoon (13:00) than those for the morning (9:00) over the 10 days. The results also show that the numbers of airborne bacteria and fungi had a daily character in indoor air and were higher in the afternoon. The airborne microbe concentrations were found to be similar to residential indoor values from other reports; the indoor museum maximum of microbial concentrations was 90 CFU/m(3) and did not exceed the Chinese indoor bioaerosol guideline. However, microorganisms may fall on the surface of display items as a result of particle sedimentation and would, as such, be capable of degrading objects by way of their secretions, e.g., enzymes and organic acids. Therefore, the right steps should be taken to prevent any deterioration in the quality of displayed artifacts. The results show that museum air was affected by human activity; therefore, it is imperative that the number of visitors be strictly limited and that windows be opened regularly to avoid air pollution. The data provide a significant scientific basis for indoor air quality control and museum scientific management. It is recommended that the number of visitors be strictly limited.

  9. Children's exposure to secondhand and thirdhand smoke carcinogens and toxicants in homes of hookah smokers.

    PubMed

    Kassem, Nada O F; Daffa, Reem M; Liles, Sandy; Jackson, Sheila R; Kassem, Noura O; Younis, Maram A; Mehta, Setoo; Chen, Menglan; Jacob, Peyton; Carmella, Steve G; Chatfield, Dale A; Benowitz, Neal L; Matt, Georg E; Hecht, Stephen S; Hovell, Melbourne F

    2014-07-01

    We examined homes of hookah-only smokers and nonsmokers for levels of indoor air nicotine (a marker of secondhand smoke) and indoor surface nicotine (a marker of thirdhand smoke), child uptake of nicotine, the carcinogen 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), and the toxicant acrolein by analyzing their corresponding metabolites cotinine, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) and NNAL-glucuronides (total NNAL) and 3-hydroxypropylmercapturic acid. Data were collected at 3 home visits during a 7-day study period from a convenience sample of 24 households with a child 5 years or younger. Three child urine samples and 2 air and surface samples from the living room and the child bedroom were taken in homes of nonsmokers (n = 5) and hookah-only smokers (n = 19) comprised of daily hookah smokers (n = 8) and weekly/monthly hookah smokers (n = 11). Nicotine levels in indoor air and on surfaces in the child bedrooms in homes of daily hookah smokers were significantly higher than in homes of nonsmokers. Uptake of nicotine, NNK, and acrolein in children living in daily hookah smoker homes was significantly higher than in children living in nonsmoker homes. Uptake of nicotine and NNK in children living in weekly/monthly hookah smoker homes was significantly higher than in children living in nonsmoker homes. Our data provide the first evidence for uptake of nicotine, the tobacco-specific lung carcinogen NNK, and the ciliatoxic and cardiotoxic agent acrolein in children living in homes of hookah smokers. Our findings suggest that daily and occasional hookah use in homes present a serious, emerging threat to children's long-term health. © The Author 2014. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Identification and quantification of indoor air pollutant sources within a residential academic campus.

    PubMed

    Suryawanshi, Shalini; Chauhan, Amit Singh; Verma, Ritika; Gupta, Tarun

    2016-11-01

    There is a growing concern regarding the adverse health effects due to indoor air pollution in developing countries including India. Hence, it becomes important to study the causes and sources of indoor air pollutants. This study presents the indoor concentrations of PM0.6 (particles with aerodynamic diameter less than 0.6μm) and identifies sources leading to indoor air pollution. Indoor air samples were collected at IIT Kanpur campus. Ninety-eight PM0.6 samples were collected during November 2013 to September 2014. PM0.6 concentration was measured using a single stage impactor type PM0.6 sampler. The average PM0.6 concentration indoor was about 94.44μg/m(3). Samples collected were then analysed for metal concentrations using ICP-OES (Inductively Coupled Plasma - Optical Emission Spectrometer). Eight metals Ba, Ca, Cr, Cu, Fe, Mg, Ni and Pb were quantified from PM samples using ICP-OES. Positive Matrix Factorization (PMF) was used for source apportionment of indoor air pollution. PMF is a factor analysis tool which helps in resolving the profile and contribution of the sources from an unknown mixture. Five possible sources of indoor pollutants were identified by factor analysis - (1) Coal combustion (21.8%) (2) Tobacco smoking (9.8%) (3) Wall dust (25.7%) (4) Soil particles (17.5%) (5) Wooden furniture/paper products (25.2%). Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Development of a modeling approach to estimate indoor-to-outdoor sulfur ratios and predict indoor PM2.5 and black carbon concentrations for Eastern Massachusetts households

    PubMed Central

    Tang, Chia Hsi; Garshick, Eric; Grady, Stephanie; Coull, Brent; Schwartz, Joel; Koutrakis, Petros

    2018-01-01

    The effects of indoor air pollution on human health have drawn increasing attention among the scientific community as individuals spend most of their time indoors. However, indoor air sampling is labor-intensive and costly, which limits the ability to study the adverse health effects related to indoor air pollutants. To overcome this challenge, many researchers have attempted to predict indoor exposures based on outdoor pollutant concentrations, home characteristics, and weather parameters. Typically, these models require knowledge of the infiltration factor, which indicates the fraction of ambient particles that penetrates indoors. For estimating indoor fine particulate matter (PM2.5) exposure, a common approach is to use the indoor-to-outdoor sulfur ratio (Sindoor/Soutdoor) as a proxy of the infiltration factor. The objective of this study was to develop a robust model that estimates Sindoor/Soutdoor for individual households that can be incorporated into models to predict indoor PM2.5 and black carbon (BC) concentrations. Overall, our model adequately estimated Sindoor/Soutdoor with an out-of-sample by home-season R2 of 0.89. Estimated Sindoor/Soutdoor reflected behaviors that influence particle infiltration, including window opening, use of forced air heating, and air purifier. Sulfur ratio-adjusted models predicted indoor PM2.5 and BC with high precision, with out-of-sample R2 values of 0.79 and 0.76, respectively. PMID:29064481

  12. Associations between self-reported in-home smoking behaviours and surface nicotine concentrations in multiunit subsidised housing.

    PubMed

    Hood, Nancy E; Ferketich, Amy K; Klein, Elizabeth G; Pirie, Phyllis; Wewers, Mary Ellen

    2014-01-01

    Smoke-free policies are being increasingly promoted and adopted in subsidised multiunit housing to address disparities in residential secondhand smoke exposure. In order to inform the planning and evaluation of these policies, this study examined associations between self-reported in-home smoking and surface nicotine concentrations. A face-to-face, cross-sectional survey was conducted from August to October 2011 with leaseholders in a probability sample of private subsidised housing units in Columbus, Ohio, without an existing smoke-free housing policy (n=301, 64% response rate). After the survey, a wipe sample was collected from a wood surface in the living room to measure surface nicotine concentrations (n=279). In-home smoking was reported by 56.6% of respondents. Geometric mean surface nicotine concentrations differed between non-smoking and smoking homes (11.4 vs 90.9 μg/m(2); p<0.001), and between homes with complete, partial and no voluntary home smoking restrictions (8.9 vs 56.3 vs 145.6 μg/m(2); p<0.001). Surface nicotine concentrations were moderately correlated (r=.52) with the total number of cigarettes smoked indoors per week. Smoking behaviours of respondents, other household members and visitors, and length of stay were independently associated with surface nicotine concentrations in a multivariable model, explaining 52% of the variance. Surface nicotine concentrations were significantly associated with a range of self-reported in-home smoking behaviours. This measure should be considered for evaluating changes in in-home smoking behaviours after implementation of smoke-free policies by subsidised housing providers. More research is needed about how surface nicotine concentrations differ over space, time and various indoor surfaces.

  13. Indoor particle levels in small- and medium-sized commercial buildings in California.

    PubMed

    Wu, Xiangmei May; Apte, Michael G; Bennett, Deborah H

    2012-11-20

    This study monitored indoor and outdoor particle concentrations in 37 small and medium commercial buildings (SMCBs) in California with three buildings sampled on two occasions, resulting in 40 sampling days. Sampled buildings included offices, retail establishments, restaurants, dental offices, and hair salons, among others. Continuous measurements were made for both ultrafine and fine particulate matter as well as black carbon inside and outside of the building. Integrated PM(2.5), PM(2.5-10), and PM(10) samples were also collected inside and outside the building. The majority of the buildings had indoor/outdoor (I/O) particle concentration ratios less than 1.0, indicating that contributions from indoor sources are less than removal of outdoor particles. However, some of the buildings had I/O ratios greater than 1, indicating significant indoor particle sources. This was particularly true of restaurants, hair salons, and dental offices. The infiltration factor was estimated from a regression analysis of indoor and outdoor concentrations for each particle size fraction, finding lower values for ultrafine and coarse particles than for submicrometer particles, as expected. The I/O ratio of black carbon was used as a relative measure of the infiltration factor of particles among buildings, with a geometric mean of 0.62. The contribution of indoor sources to indoor particle levels was estimated for each building.

  14. Modeling Human Exposure to Indoor Contaminants: External Source to Body Tissues.

    PubMed

    Webster, Eva M; Qian, Hua; Mackay, Donald; Christensen, Rebecca D; Tietjen, Britta; Zaleski, Rosemary

    2016-08-16

    Information on human indoor exposure is necessary to assess the potential risk to individuals from many chemicals of interest. Dynamic indoor and human physicologically based pharmacokinetic (PBPK) models of the distribution of nonionizing, organic chemical concentrations in indoor environments resulting in delivered tissue doses are developed, described and tested. The Indoor model successfully reproduced independently measured, reported time-dependent air concentrations of chloroform released during showering and of 2-butyoxyethanol following use of a volatile surface cleaner. The Indoor model predictions were also comparable to those from a higher tier consumer model (ConsExpo 4.1) for the surface cleaner scenario. The PBPK model successful reproduced observed chloroform exhaled air concentrations resulting from an inhalation exposure. Fugacity based modeling provided a seamless description of the partitioning, fluxes, accumulation and release of the chemical in indoor media and tissues of the exposed subject. This has the potential to assist in health risk assessments, provided that appropriate physical/chemical property, usage characteristics, and toxicological information are available.

  15. Polybrominated diphenyl ether (PBDE) concentrations and resulting exposure in homes in California: relationships among passive air, surface wipe and dust concentrations, and temporal variability.

    PubMed

    Bennett, D H; Moran, R E; Wu, X May; Tulve, N S; Clifton, M S; Colón, M; Weathers, W; Sjödin, A; Jones, R; Hertz-Picciotto, I

    2015-04-01

    Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive air, floor and indoor window surface wipes, and dust samples (investigator collected using an HVS3 and vacuum cleaner) in each home. PentaBDE and BDE209 were detected in the majority of the dust samples and many floor wipe samples, but the detection in air and window wipe samples was relatively low. Concentrations of each PBDE congener in different indoor environmental media were moderately correlated, with correlation coefficients ranging between 0.42 and 0.68. Correlation coefficients with blood levels were up to 0.65 and varied between environmental media and age group. Both investigator-collected dust and floor wipes were correlated with serum levels for a wide range of congeners. These two sample types also had a relatively high fraction of samples with adequate mass for reliable quantification. In 42 homes, PBDE levels measured in the same environmental media in the same home 1 year apart were statistically correlated (correlation coefficients: 0.57-0.90), with the exception of BDE209 which was not well correlated longitudinally. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Ecological succession of the microbial communities of an air-conditioning cooling coil in the tropics.

    PubMed

    Acerbi, E; Chénard, C; Miller, D; Gaultier, N E; Heinle, C E; Chang, V W-C; Uchida, A; Drautz-Moses, D I; Schuster, S C; Lauro, F M

    2017-03-01

    Air-conditioning systems harbor microorganisms, potentially spreading them to indoor environments. While air and surfaces in air-conditioning systems are periodically sampled as potential sources of indoor microbes, little is known about the dynamics of cooling coil-associated communities and their effect on the downstream airflow. Here, we conducted a 4-week time series sampling to characterize the succession of an air-conditioning duct and cooling coil after cleaning. Using an universal primer pair targeting hypervariable regions of the 16S/18S ribosomal RNA, we observed a community succession for the condensed water, with the most abundant airborne taxon Agaricomycetes fungi dominating the initial phase and Sphingomonas bacteria becoming the most prevalent taxa toward the end of the experiment. Duplicate air samples collected upstream and downstream of the coil suggest that the system does not act as ecological filter or source/sink for specific microbial taxa during the duration of the experiment. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. MEASUREMENTS OF TRANSFERRABLE RESIDUE FROM CERAMIC TILE, VINYL TILE, HARDWOOD FLOORING, AND CARPET USING A PRESS SAMPLER AND C18, PUF, AND COTTON SAMPLING DISKS

    EPA Science Inventory

    Unintentional and avoidable human exposure is a consequence of pesticide use indoors. Pesticides on household surfaces are a source of exposure to children. Therefore, concern has been raised regarding the potential for contamination of foods in homes where pesticides have been...

  18. Integrated analysis of numerical weather prediction and computational fluid dynamics for estimating cross-ventilation effects on inhaled air quality inside a factory

    NASA Astrophysics Data System (ADS)

    Murga, Alicia; Sano, Yusuke; Kawamoto, Yoichi; Ito, Kazuhide

    2017-10-01

    Mechanical and passive ventilation strategies directly impact indoor air quality. Passive ventilation has recently become widespread owing to its ability to reduce energy demand in buildings, such as the case of natural or cross ventilation. To understand the effect of natural ventilation on indoor environmental quality, outdoor-indoor flow paths need to be analyzed as functions of urban atmospheric conditions, topology of the built environment, and indoor conditions. Wind-driven natural ventilation (e.g., cross ventilation) can be calculated through the wind pressure coefficient distributions of outdoor wall surfaces and openings of a building, allowing the study of indoor air parameters and airborne contaminant concentrations. Variations in outside parameters will directly impact indoor air quality and residents' health. Numerical modeling can contribute to comprehend these various parameters because it allows full control of boundary conditions and sampling points. In this study, numerical weather prediction modeling was used to calculate wind profiles/distributions at the atmospheric scale, and computational fluid dynamics was used to model detailed urban and indoor flows, which were then integrated into a dynamic downscaling analysis to predict specific urban wind parameters from the atmospheric to built-environment scale. Wind velocity and contaminant concentration distributions inside a factory building were analyzed to assess the quality of the human working environment by using a computer simulated person. The impact of cross ventilation flows and its variations on local average contaminant concentration around a factory worker, and inhaled contaminant dose, were then discussed.

  19. The effects of an energy efficiency retrofit on indoor air quality.

    PubMed

    Frey, S E; Destaillats, H; Cohn, S; Ahrentzen, S; Fraser, M P

    2015-04-01

    To investigate the impacts of an energy efficiency retrofit, indoor air quality and resident health were evaluated at a low-income senior housing apartment complex in Phoenix, Arizona, before and after a green energy building renovation. Indoor and outdoor air quality sampling was carried out simultaneously with a questionnaire to characterize personal habits and general health of residents. Measured indoor formaldehyde levels before the building retrofit routinely exceeded reference exposure limits, but in the long-term follow-up sampling, indoor formaldehyde decreased for the entire study population by a statistically significant margin. Indoor PM levels were dominated by fine particles and showed a statistically significant decrease in the long-term follow-up sampling within certain resident subpopulations (i.e. residents who report smoking and residents who had lived longer at the apartment complex). © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. ORGANOCHLORINE PESTICIDE CONCENTRATIONS AND ENANTIOMER FRACTIONS FOR CHLORDANE IN INDOOR AIR FROM THE U.S. CORNBELT

    EPA Science Inventory

    Thirty-seven indoor air samples were collected and analyzed to determine if enantioselective degradation of past use organochlorine pesticides occurs indoors and to increase the available information on concentrations in homes. Samples were collected from homes in the U.S. cor...

  1. May 2011 Groundwater and Surface Water Sampling at the Rio Blanco, Colorado, Site (Data Validation Package)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hutton, Rick

    2011-12-01

    Annual sampling was conducted at the Rio Blanco, Colorado, site for the Long-Term Hydrologic Monitoring Program May 16-17, 2011, to monitor groundwater and surface water for potential radionuclide contamination. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for the U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). A duplicate sample was collected from location Johnson Artesian WL. Samples were analyzed by the U.S. Environmental Protection Agency (EPA) Radiation&Indoor Environments National Laboratory in Las Vegas, Nevada. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry, and for tritium using the conventional method.more » Tritium was not measured using the enrichment method because the EPA laboratory no longer offers that service. Results of this monitoring at the Rio Blanco site demonstrate that groundwater and surface water outside the boundaries have not been affected by project-related contaminants.« less

  2. Occurrence of the off-host life stages of Tunga penetrans (Siphonaptera) in various environments in Brazil.

    PubMed

    Linardi, P M; Calheiros, C M L; Campelo-Junior, E B; Duarte, E M; Heukelbach, J; Feldmeier, H

    2010-06-01

    To explore the local transmission dynamics of Tunga penetrans in brazil, 134 soil samples from various environments were collected in three different endemic regions of the country and checked for the presence of the flea's larvae, pupae and adults. the samples, which came from an urban slum in the north-east, a village of xavante indians in the central-west and a community of yanomami indians living in traditional longhouses (malocas) in the north, were categorized as indoor, outdoor or indoor-outdoor (the latter representing samples collected in the malocas). The proportion of samples found positive for T. penetrans was lowest in the slum (9.3%) and highest in the Yanomami village (32.0%; P=0.01). Soil samples collected below bedsteads or hammocks or from the indoor resting places of dogs were significantly more likely to be positive than the indoor samples collected at other sites (65.0% v. 35.0%; P=0.02). There was no evidence indicating that the presence of T. penetrans in a soil sample was markedly affected by soil temperature, air temperature or air humidity. As no life stages of T. penetrans were found in any outdoor sample, it seems likely that, in resource-poor settings in Brazil, most transmission of T. penetrans occurs indoors. Control measures against the off-host life stages of T. penetrans should therefore be targeted at particular indoor micro-environments.

  3. The Inside Information about Safety Surfacing.

    ERIC Educational Resources Information Center

    Thompson, Donna; Hudson, Susan

    2003-01-01

    Tested the impact attenuation characteristics of safety surfaces used in indoor child care play settings. Found that the most common surfaces used were indoor/outdoor carpet, various types of mats, and safety floor tiles. Nearly 60 percent of tested materials had a critical fall height of 1 foot or less. Concluded that carpet, safety tile, and…

  4. PASSIVE/DIFFUSIVE SAMPLERS FOR PESTICIDES IN RESIDENTIAL INDOOR AIR

    EPA Science Inventory

    Pesticides applied indoors vaporize from treated surfaces (e.g., carpets and baseboards) resulting in elevated air concentrations that may persist for long periods after applications. Estimating long-term respiratory exposures to pesticide vapors in residential indoor environme...

  5. Evaluation and guidelines for using polyurethane foam (PUF) passive air samplers in double-dome chambers to assess semi-volatile organic compounds (SVOCs) in non-industrial indoor environments.

    PubMed

    Bohlin, Pernilla; Audy, Ondřej; Škrdlíková, Lenka; Kukučka, Petr; Vojta, Šimon; Přibylová, Petra; Prokeš, Roman; Čupr, Pavel; Klánová, Jana

    2014-11-01

    Indoor air pollution has been recognized as an important risk factor for human health, especially in areas where people tend to spend most of their time indoors. Many semi-volatile organic compounds (SVOCs) have primarily indoor sources and are present in orders of magnitude higher concentrations indoors than outdoors. Despite this, awareness of SVOCs in indoor air and assessment of the link between indoor concentrations and human health have lagged behind those of outdoor air. This is partially related to challenges associated with indoor sampling of SVOCs. Passive air samplers (PASs), which are widely accepted in established outdoor air monitoring networks, have been used to fill the knowledge gaps on indoor SVOCs distribution. However, their applicability for indoor environments and the assessment of human health risks lack sufficient experimental data. To address this issue, we performed an indoor calibration study of polyurethane foam (PUF) PAS deployed in a double-dome chamber, covering both legacy and new SVOC classes. PUF-PAS and a continuous low-volume active air sampler (AAS) were co-deployed for a calibration period of twelve weeks. Based on the results from this evaluation, PUF-PAS in a double-bowl chamber is recommended for indoor sampling and health risk assessment of gas phase SVOCs, including novel brominated flame retardants (nBFR) providing sufficient exposure time is applied. Data for particle associated SVOCs suffered from significant uncertainties caused by low level of detection and low precision in this study. A more open chamber design for indoor studies may allow for higher sampling rates (RS) and better performance for the particle associated SVOCs.

  6. The impact of wood stove technology upgrades on indoor residential air quality

    NASA Astrophysics Data System (ADS)

    Allen, Ryan W.; Leckie, Sara; Millar, Gail; Brauer, Michael

    2009-12-01

    Fine particulate matter (PM 2.5) air pollution has been linked to adverse health impacts, and combustion sources including residential wood-burning may play an important role in some regions. Recent evidence suggests that indoor air quality may improve in homes where older, non-certified wood stoves are exchanged for lower emissions EPA-certified alternatives. As part of a wood stove exchange program in northern British Columbia, Canada, we sampled outdoor and indoor air at 15 homes during 6-day sampling sessions both before and after non-certified wood stoves were exchanged. During each sampling session two consecutive 3-day PM 2.5 samples were collected onto Teflon filters, which were weighed and analyzed for the wood smoke tracer levoglucosan. Residential PM 2.5 infiltration efficiencies ( Finf) were estimated from continuous light scattering measurements made with nephelometers, and estimates of Finf were used to calculate the outdoor- and indoor-generated contributions to indoor air. There was not a consistent relationship between stove technology and outdoor or indoor concentrations of PM 2.5 or levoglucosan. Mean Finf estimates were low and similar during pre- and post-exchange periods (0.32 ± 0.17 and 0.33 ± 0.17, respectively). Indoor sources contributed the majority (˜65%) of the indoor PM 2.5 concentrations, independent of stove technology, although low indoor-outdoor levoglucosan ratios (median ≤ 0.19) and low indoor PM 2.5-levoglucosan correlations ( r ≤ 0.19) suggested that wood smoke was not a major indoor PM 2.5 source in most of these homes. In summary, despite the potential for extensive wood stove exchange programs to reduce outdoor PM 2.5 concentrations in wood smoke-impacted communities, we did not find a consistent relationship between stove technology upgrades and indoor air quality improvements in homes where stoves were exchanged.

  7. TESTING ANTIMICROBIAL EFFICACY ON POROUS MATERIALS

    EPA Science Inventory

    The efficacy of antimicrobial treatments to eliminate or control biological growth in the indoor environment can easily be tested on nonporous surfaces. However, the testing of antimicrobial efficacy on porous surfaces, such as those found in the indoor environment [i.e., gypsum ...

  8. Structure and properties of silk from the African wild silkmoth Gonometa postica reared indoors

    PubMed Central

    Teshome, Addis; Raina, S. K.; Vollrath, Fritz

    2014-01-01

    Abstract African wild silkmoth, Gonometa postica Walker (Lepidoptera: Lasiocampidae), were reared indoors in order to examine the influence of rearing conditions on the structure and properties of silk cocoon shells and degummed fibers by using a scanning electron microscope, an Instron tensile tester, and a thermogravimetric analyzer. The cocoons reared indoors showed inferior quality in weight, length, width, and cocoon shell ratio compared to cocoons reared outdoors. There were no differences in cocoon shell and fiber surfaces and cross sectional structures. Cocoon shells were covered with calcium oxalate crystals with few visible fibers on their surface. Degummed fibers were smooth with minimum unfractured surfaces and globular to triangular cross sections. Indoor-reared cocoon shells had a significantly higher breaking strain, while the breaking stress was higher for cocoons reared outdoors. Fibers from indoor cocoons had a significantly higher breaking stress while outdoor fibers had higher breaking strain. Thermogravimetric analysis curves showed two main thermal reactions revealing the dehydration of water molecules and ir-reversible decomposition of the crystallites in both cocoons and fibers reared indoors and outdoors. Cocoon shells underwent additional peaks of decomposition with increased temperature. The total weight loss was higher for cocoon shells and degummed fibers from indoors. Rearing conditions (temperature and relative humidity), feeding method used, changes in total life span, days to molting, and spinning might have influenced the variation in the properties observed.The ecological and commercial significances of indoor rearing of G. postica are discussed. PMID:25373183

  9. Building-related symptoms are linked to the in vitro toxicity of indoor dust and airborne microbial propagules in schools: A cross-sectional study.

    PubMed

    Salin, J T; Salkinoja-Salonen, M; Salin, P J; Nelo, K; Holma, T; Ohtonen, P; Syrjälä, H

    2017-04-01

    Indoor microbial toxicity is suspected to cause some building-related symptoms, but supporting epidemiological data are lacking. We examined whether the in vitro toxicity of indoor samples from school buildings was associated with work-related health symptoms (building-related symptoms, BRS). Administrators of the Helsinki City Real Estate Department selected 15 schools for the study, and a questionnaire on symptoms connected to work was sent to the teachers in the selected schools for voluntary completion. The cellular toxicity of classroom samples was determined by testing substances extracted from wiped indoor dust and by testing microbial biomass that was cultured on fallout plates. Boar sperm cells were used as indicator cells, and motility loss was the indicator for toxic effects. The effects were expressed as the half maximal effective concentration (EC 50 ) at which >50% of the exposed boar sperm cells were immobile compared to vehicle control. Completed symptom questionnaires were received from 232 teachers [median age, 43 years; 190 (82.3%) women] with a median time of 6 years working at their school. Samples from their classrooms were available and were assessed for cellular toxicity. The Poisson regression model showed that the impact of extracts of surface-wiped school classroom dust on teacher work-related BRS was 2.8-fold (95% CI: 1.6-4.9) higher in classrooms with a toxic threshold EC 50 of 6µgml -1 versus classrooms with insignificant EC 50 values (EC 50 >50µgml -1 ); P<0.001. The number of symptoms that were alleviated during vacation was higher in school classrooms with high sperm toxicity compared to less toxic sites; the RR was 1.9 (95% CI: 1.1-3.3, P=0.03) for wiped dust extracts. Teachers working in classrooms where the samples showed high sperm toxicity had more BRS. The boar sperm cell motility inhibition assay appears promising as a tool for demonstrating the presence of indoor substances associated with BRS. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Effect of temperature and humidity on formaldehyde emissions in temporary housing units.

    PubMed

    Parthasarathy, Srinandini; Maddalena, Randy L; Russell, Marion L; Apte, Michael G

    2011-06-01

    The effect of temperature and humidity on formaldehyde emissions from samples collected from temporary housing units (THUs) was studied. The THUs were supplied by the U.S. Federal Emergency Management Administration (FEMA) to families that lost their homes in Louisiana and Mississippi during the Hurricane Katrina and Rita disasters. On the basis of a previous study, four of the composite wood surface materials that dominated contributions to indoor formaldehyde were selected to analyze the effects of temperature and humidity on the emission factors. Humidity equilibration experiments were carried out on two of the samples to determine how long the samples take to equilibrate with the surrounding environmental conditions. Small chamber experiments were then conducted to measure emission factors for the four surface materials at various temperature and humidity conditions. The samples were analyzed for formaldehyde via high-performance liquid chromatography. The experiments showed that increases in temperature or humidity contributed to an increase in emission factors. A linear regression model was built using the natural log of the percent relative humidity (RH) and inverse of temperature (in K) as independent variables and the natural log of emission factors as the dependent variable. The coefficients for the inverse of temperature and log RH with log emission factor were found to be statistically significant for all of the samples at the 95% confidence level. This study should assist in retrospectively estimating indoor formaldehyde exposure of occupants of THUs.

  11. Brominated and phosphate flame retardants (FRs) in indoor dust from different microenvironments: Implications for human exposure via dust ingestion and dermal contact.

    PubMed

    Zheng, Xiaobo; Qiao, Lin; Covaci, Adrian; Sun, Runxia; Guo, Huiying; Zheng, Jing; Luo, Xiaojun; Xie, Qilai; Mai, Bixian

    2017-10-01

    Indoor dust has been widely used to monitor flame retardants (FRs) in indoor environment, but most studies only focused on floor dust. In the present study, FRs were examined in indoor dust from different locations. Dust from air conditioner (AC) filters, beddings, floor, and windows in bedrooms, and dust from AC filters, printer table surface, computer table surface, floor, and windows in offices were collected, respectively. Polybrominated diphenyl ether congener 209 (BDE 209) and decabromodiphenyl ethane (DBDPE) were the most abundant brominated flame retardants (BFRs), and tris(chloroisopropyl) phosphate (TCIPP), tris(1,3-dichloroisopropyl) phosphate (TDCIPP), and triphenyl phosphate (TPHP) were the most abundant phosphate flame retardants (PFRs). In bedrooms, the AC filter dust had the highest median levels of BDE 209 (536 ng/g) and DBDPE (2720 ng/g), while bed dust had the highest median levels of ΣPFRs (2750 ng/g) among dust samples. In offices, printer table dust had higher median levels of BDE 209 (1330 ng/g), DBDPE (8470 ng/g), and ΣPFRs (11,000 ng/g) than those in other dust samples. The high dust ingestion values of BDE 209, DBDPE, and individual PFR were 0.28, 1.20, and <0.01-0.32 ng/kg bw/day and 7.37, 31.2, and <0.01-4.54 ng/kg bw/day for BDE 209, DBDPE, and individual PFR for adults and toddlers, respectively. The high dermal exposure values of individual PFR during sleeping were <0.01-0.23 and <0.01-0.36 ng/kg bw/day for adults and toddlers, respectively. More human exposure pathways other than dust ingestion should be considered, such as the dermal contact with beddings and furniture. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. THE INTERACTION OF VAPOUR PHASE ORGANIC COMPOUNDS WITH INDOOR SINKS

    EPA Science Inventory

    The interaction of indoor air pollutants with interior surfaces (i.e., sinks) is a well known, but poorly understood, phenomenon. Studies have shown that re-emissions of adsorbed organic vapours can contribute to elevated concentrations of organics in indoor environments. Researc...

  13. Natural radioactivity, radon exhalation rates and indoor radon concentration of some granite samples used as construction material in Turkey.

    PubMed

    Aykamis, Ahmet S; Turhan, Seref; Aysun Ugur, F; Baykan, Umut N; Kiliç, Ahmet M

    2013-11-01

    It is very important to determine the levels of the natural radioactivity in construction materials and radon exhalation rate from these materials for assessing potential exposure risks for the residents. The present study deals with 22 different granite samples employed as decoration stones in constructions in Turkey. The natural radioactivity in granite samples was measured by gamma-ray spectrometry with an HPGe detector. The activity concentrations of (226)Ra, (232)Th and (40)K were found to be in the range of 10-187, 16-354 and 104-1630 Bq kg(-1), respectively. The radon surface exhalation rate and the radon mass exhalation rate estimated from the measured values of (226)Ra content and material properties varied from 1.3 to 24.8 Bq m(-2) h(-1) with a mean of 10.5±1.5 Bq m(-2) h(-1) and 0.03-0.64 Bq kg(-1) h(-1) with a mean of 0.27±0.04 Bq kg(-1) h(-1), respectively. Radon concentrations in the room caused from granite samples estimated using a mass balance equation varied from 23 to 461 Bq m(-3) with a mean of 196±27 Bq m(-3). Also the gamma index (Iγ), external indoor annual effective dose (Eγ) and annual effective dose due to the indoor radon exposure (ERn) were estimated as the average value of 1.1±0.1, 0.16±0.02 mSv and 5.0±0.7 mSv, respectively, for the granite samples.

  14. Air-conditioning vs. presence of pathogenic fungi in hospital operating theatre environment.

    PubMed

    Gniadek, Agnieszka; Macura, Anna B

    2011-01-01

    Infections related to modern surgical procedures present a difficult problem for contemporary medicine. Infections acquired during surgery represent a risk factor related to therapeutical interventions. Eradication of microorganisms from hospital operating theatre environment may contribute to reduction of infections as the laminar flow air-conditioning considerably reduces the number of microorganisms in the hospital environment. The objective of the study was to evaluate the occurrence of fungi in air-conditioned operating theatre rooms. The study was carried out in one of the hospitals in Krak6w during December 2009. Indoor air samples and imprints from the walls were collected from five operating theatre rooms. A total of fifty indoor air samples were collected with a MAS-100 device, and twenty five imprints from the walls were collected using a Count Tact method. Fungal growth was observed in 48 air samples; the average numbers of fungi were within the range of 5-100 c.f.u. in one cubic metre of the air. Fungi were detected only in four samples of the wall imprints; the number of fungi was 0.01 c.f.u. per one square centimetre of the surface. The mould genus Aspergillus was most frequently isolated, and the species A. fumigatus and A. versicolor were the dominating ones. To ensure microbiological cleanness of hospital operating theatre, the air-conditioning system should be properly maintained. Domination of the Aspergillus fungi in indoor air as well as increase in the number of moulds in the samples taken in evenings (p < 0.05) may suggest that the room decontamination procedures were neglected.

  15. Sorption, desorption, and surface oxidative fate of nicotine.

    PubMed

    Petrick, Lauren; Destaillats, Hugo; Zouev, Irena; Sabach, Sara; Dubowski, Yael

    2010-09-21

    Nicotine dynamics in an indoor environment can be greatly affected by building parameters (e.g. relative humidity (RH), air exchange rate (AER), and presence of ozone), as well as surface parameters (e.g. surface area (SA) and polarity). To better understand the indoor fate of nicotine, these parameter effects on its sorption, desorption, and oxidation rates were investigated on model indoor surfaces that included fabrics, wallboard paper, and wood materials. Nicotine sorption under dry conditions was enhanced by higher SA and higher polarity of the substrate. Interestingly, nicotine sorption to cotton and nylon was facilitated by increased RH, while sorption to polyester was hindered by it. Desorption was affected by RH, AER, and surface type. Heterogeneous nicotine-ozone reaction was investigated by Fourier transform infrared spectrometry with attenuated total reflection (FTIR-ATR), and revealed a pseudo first-order surface reaction rate of 0.035 +/- 0.015 min(-1) (at [O(3)] = 6 +/- 0.3 x 10(15) molecules cm(-3)) that was partially inhibited at high RH. Extrapolation to a lower ozone level ([O(3)] = 42 ppb) showed oxidation on the order of 10(-5) min(-1) corresponding to a half-life of 1 week. In addition, similar surface products were identified in dry and high RH using gas chromatography-mass spectrometry (GC-MS). However, FTIR analysis revealed different product spectra for these conditions, suggesting additional unidentified products and association with surface water. Knowing the indoor fate of condensed and gas phase nicotine and its oxidation products will provide a better understanding of nicotine's impact on personal exposures as well as overall indoor air quality.

  16. Results of a long-term study of vapor intrusion at four large buildings at the NASA Ames Research Center.

    PubMed

    Brenner, David

    2010-06-01

    Most of the published empirical data on indoor air concentrations resulting from vapor intrusion of contaminants from underlying groundwater are for residential structures. The National Aeronautics and Space Administration (NASA) Research Park site, located in Moffett Field, CA, and comprised of 213 acres, is being planned for redevelopment as a collaborative research and educational campus with associated facilities. Groundwater contaminated with hydrocarbon and halogenated hydrocarbon volatile organic compounds (VOCs) is the primary environmental medium of concern at the site. Over a 15-month period, approximately 1000 indoor, outdoor ambient, and outdoor ambient background samples were collected from four buildings designated as historical landmarks using Summa canisters and analyzed by the U.S. Environmental Protection Agency TO-15 selective ion mode. Both 24-hr and sequential 8-hr samples were collected. Comparison of daily sampling results relative to daily background results indicates that the measured trichloroethylene (TCE) concentrations were primarily due to the subsurface vapor intrusion pathway, although there is likely some contribution due to infiltration of TCE from the outdoor ambient background concentrations. Analysis of the cis-1,2-dichloroethylene concentrations relative to TCE concentrations with respect to indoor air concentrations and the background air support this hypothesis; however, this indicates that relative contributions of the vapor intrusion and infiltration pathways vary with each building. Indoor TCE concentrations were also compared with indoor benzene and background benzene concentrations. These data indicate significant correlation between background benzene concentrations and the concentration of benzene in the indoor air, indicating benzene was present in the indoor air primarily through infiltration of outdoor air into the indoor space. By comparison, measured TCE indoor air concentrations showed a significantly different relationship to background concentrations. Analysis of the results show that indoor air samples can be used to definitively define the source of the TCE present in the indoor air space of large industrial buildings.

  17. Photocatalytic surface reactions on indoor wall paint.

    PubMed

    Salthammer, T; Fuhrmann, F

    2007-09-15

    The reduction of indoor air pollutants by air cleaning systems has received considerable interest, and a number of techniques are now available. So far, the method of photocatalysis was mainly applied by use of titanium dioxide (TiO2) in flow reactors under UV light of high intensity. Nowadays, indoor wall paints are equipped with modified TiO2 to work as a catalyst under indoor daylight or artificial light. In chamber experiments carried out under indoor related conditions itwas shown thatthe method works for nitrogen dioxide with air exchange and for formaldehyde without air exchange at high concentrations. In further experiments with volatile organic compounds (VOCs), a small effect was found for terpenoids with high kOH rate constants. For other VOCs and carbon monoxide there was no degradation at all or the surface acted as a reversible sink. Secondary emissions from the reaction of paint constituents were observed on exposure to light. From the results it is concluded that recipes of photocatalytic wall paints need to be optimized for better efficiency under indoor conditions.

  18. Endotoxins in Environmental and Clinical Samples Assessed by GC-Tandem MS

    NASA Astrophysics Data System (ADS)

    Szponar, Bogumila

    Bacteria appeared on the Earth millions years before us and human evolution was triggered by the constant presence of pathogenic and symbiotic microorganisms in our surroundings. Interplay occurred between higher organism and microbial consortia residing in the host organs and on the epithelial surfaces; another natural space of bacteria-human interaction is the indoor environment where we spend the majority of our lifetime. Indoor microbial exposure affects our well-being and can result in respiratory symptoms, such as allergies and asthma, since both dead and live microorganisms and their cell constituents, including lipopolysaccharides (LPS, endotoxins), interact with our immune system. Thus, there is a demand for robust tools for qualitative and quantitative determination of the microbial communities that we are exposed to.

  19. Four passive sampling elements (quatrefoil)--I. Monitoring radon and its progeny by surface-contamination monitors.

    PubMed

    Tommasino, L; Tokonami, S

    2011-05-01

    Four passive sampling elements (quatrefoil) have been recently developed, which transform airborne radionuclides into surface-bound radionuclides. These samplers, once exposed, result in thin radiation sources that can be detected by any real-time or passive detector. In particular, by using a large collecting-area sampler with a low surface density (g cm(-2)), it is possible to measure radon and its decay products by beta surface-contamination monitors, which are rarely used for these applications. The results obtained to date prove that it is finally possible to carry out the measurements of radon (and its decay products) indoors, in soil and in water simply by a Pancake Geiger-Muller counter. Emphasis will be given to those measurements, which are difficult, if not impossible, to carry out with existing technologies.

  20. Determination of 14C/ 12C of acetaldehyde in indoor air by compound specific radiocarbon analysis

    NASA Astrophysics Data System (ADS)

    Kato, Yoshimi; Shinohara, Naohide; Yoshinaga, Jun; Uchida, Masao; Matsuda, Ayuri; Yoneda, Minoru; Shibata, Yasuyuki

    A method of compound-specific radiocarbon analysis (CSRA) for acetaldehyde in indoor air was established for the source apportionment purpose and the methodology was applied to indoor air samples. Acetaldehyde in indoor air samples was collected using the conventional 2,4-dinitrophenylhydrazine (DNPH) derivatization method. Typically 24-h air sampling at 5-10 L min -1 allowed collection of adequate amount of acetaldehyde for radiocarbon analysis by accelerator mass spectrometry (AMS). The 14C abundance of acetaldehyde in indoor air was measured by AMS after solvent extraction of derivatized acetaldehyde and sequential purification by a preparative liquid chromatography system and a preparative capillary gas chromatography system. The recovery and purity of the derivatized acetaldehyde was satisfactory for 14C analysis by AMS. 14C abundance of acetaldehyde was calculated by considering that of derivatizing agent DNPH. Our preliminary survey showed that percent modern carbon (pMC) values of acetaldehyde isolated from indoor air sampled in newly built, unoccupied housings ( n=5) in the suburb of Tokyo ranged from 49.4 to 67.0. This result indicated that contribution of anthropogenic source was greater than previously expected.

  1. The surface emissions trap: a new approach in indoor air purification.

    PubMed

    Markowicz, Pawel; Larsson, Lennart

    2012-11-01

    A new device for stopping or reducing potentially irritating or harmful emissions from surfaces indoors is described. The device is a surface emissions trap prototype and consists of an adsorbent sheet with a semipermeable barrier surrounded by two thin nonwoven layers. The trap may be applied directly at the source of the emissions e.g. at moisture-affected floors and walls, surfaces contaminated by chemical spills etc. This results in an immediate stop or reduction of the emitting pollutants. The trap has a very low water vapor resistance thus allowing drying of wet surfaces. In laboratory experiments typically 98% reduction of air concentrations of volatile organic compounds and a virtually total reduction of mold particle-associated mycotoxins was observed. The surface emissions trap may represent a convenient and efficient way of restoring indoor environments polluted by microbial and other moisture-associated emissions. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Office space bacterial abundance and diversity in three metropolitan areas.

    PubMed

    Hewitt, Krissi M; Gerba, Charles P; Maxwell, Sheri L; Kelley, Scott T

    2012-01-01

    People in developed countries spend approximately 90% of their lives indoors, yet we know little about the source and diversity of microbes in built environments. In this study, we combined culture-based cell counting and multiplexed pyrosequencing of environmental ribosomal RNA (rRNA) gene sequences to investigate office space bacterial diversity in three metropolitan areas. Five surfaces common to all offices were sampled using sterile double-tipped swabs, one tip for culturing and one for DNA extraction, in 30 different offices per city (90 offices, 450 total samples). 16S rRNA gene sequences were PCR amplified using bar-coded "universal" bacterial primers from 54 of the surfaces (18 per city) and pooled for pyrosequencing. A three-factorial Analysis of Variance (ANOVA) found significant differences in viable bacterial abundance between offices inhabited by men or women, among the various surface types, and among cities. Multiplex pyrosequencing identified more than 500 bacterial genera from 20 different bacterial divisions. The most abundant of these genera tended to be common inhabitants of human skin, nasal, oral or intestinal cavities. Other commonly occurring genera appeared to have environmental origins (e.g., soils). There were no significant differences in the bacterial diversity between offices inhabited by men or women or among surfaces, but the bacterial community diversity of the Tucson samples was clearly distinguishable from that of New York and San Francisco, which were indistinguishable. Overall, our comprehensive molecular analysis of office building microbial diversity shows the potential of these methods for studying patterns and origins of indoor bacterial contamination. "[H]umans move through a sea of microbial life that is seldom perceived except in the context of potential disease and decay." - Feazel et al. (2009).

  3. CHARACTERIZATION OF EMISSIONS OF VOLATILE ORGANIC COMPOUNDS FROM INTERIOR ALKYD PAINT

    EPA Science Inventory

    Alkyd paint continues to be used indoors for application to wood trim, cabinet surfaces, and some kitchen and bathroom walls. Paint may represent a significant source of volatile organic compounds (VOCs) indoors depending on the frequency of use and amount of surface paint. The U...

  4. New insight into the distribution pattern, levels, and risk diagnosis of FRs in indoor and outdoor air at low- and high-altitude zones of Pakistan: Implications for sources and exposure.

    PubMed

    Khan, Muhammad Usman; Besis, Athanasios; Li, Jun; Zhang, Gan; Malik, Riffat Naseem

    2017-10-01

    Data regarding flame retardants (FRs) in indoor and outdoor air and their exposure to population are scarce and especially unknown in the case of Pakistan. The current study was designed to probe FR concentrations and distribution pattern in indoor and outdoor air at different altitudinal zones (DAZs) of Pakistan with special emphasis on their risk to the exposed population. In this study, passive air samplers for the purpose of FR deposition were deployed in indoor and outdoor air at the industrial, rural, and background/colder zones/sites. All the indoor and outdoor air samples collected from DAZs were analyzed for the target FRs (9.30-472.30 pg/m 3 ), showing a decreasing trend as follows: ∑NBFRs > ∑PBDEs > ∑DP. However, significant correlations among FRs in the indoor and outdoor air at DAZs signified a similar source of FR origin that is used in different consumer goods. Furthermore, air mass trajectories revealed that movement of air over industrial area sources influenced concentrations of FRs at rural sites. The FR concentrations, estimated daily intake (EDI) and the hazard quotient (HQ), were recorded to be higher in toddlers than those in adults. In addition, indoor air samples showed higher FR levels, EDI and HQ, than outdoor air samples. An elevated FR concentrations and their prevalent exposure risks were recorded in the industrial zones followed by rural and background zones. The HQ for BDE-47 and BDE-99 in the indoor and outdoor air samples at different industrial and rural sites were recorded to be >1 in toddlers and adults, this further warrants a health risk in the population. However, FR investigation in indoor and outdoor air samples will provide a baseline data in Pakistan to take further steps by the government and agencies for its implementations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. INDIVIDUAL PARTICLE ANALYSIS OF INDOOR, OUTDOOR, AND PERSONAL SAMPLES FROM THE 1998 BALTIMORE RETIREMENT HOME STUDY

    EPA Science Inventory

    Particle sampling was conducted outdoors, indoors, in apartment residences, and on individual residents (i.e., personal samples) at a retirement center in the Towson area of northern Baltimore County. Concurrent particle sampling was conducted at a central community site closer...

  6. The influence of α-Al2O3 addition on microstructure, mechanical and formaldehyde adsorption properties of fly ash-based geopolymer products.

    PubMed

    Huang, Yi; Han, Minfang

    2011-10-15

    Fly ash-based geopolymer with α-Al(2)O(3) addition were synthesized and used to remove formaldehyde from indoor air. The microstructure, mechanical and formaldehyde adsorption properties of the geopolymer products obtained were investigated. The results showed that α-Al(2)O(3) addition with appropriate amount (such as 5 wt%) increased the geopolymerization extent, resulting in the increase of surface area and compressive strength. In addition, the improvement of structural ordering level for geopolymer sample with 5 wt% α-Al(2)O(3) addition was found through FTIR analysis. By contrast, excessive addition (such as 10 wt%) had the opposite effect. The test of formaldehyde adsorption capacity confirmed that fly ash-based geopolymer product exhibited much better property of adsorbing indoor formaldehyde physically and chemically than fly ash itself. The surface area was an important but not unique factor influencing the adsorption capacity of geopolymers. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Characterization of the bacterial and fungal microbiome in indoor dust and outdoor air samples: a pilot study.

    PubMed

    Hanson, Blake; Zhou, Yanjiao; Bautista, Eddy J; Urch, Bruce; Speck, Mary; Silverman, Frances; Muilenberg, Michael; Phipatanakul, Wanda; Weinstock, George; Sodergren, Erica; Gold, Diane R; Sordillo, Joanne E

    2016-06-15

    Environmental microbes have been associated with both protective and adverse health effects in children and adults. Epidemiological studies often rely on broad biomarkers of microbial exposure (i.e. endotoxin, 1 → 3-beta-d-glucan), but fail to identify the taxonomic composition of the microbial community. Our aim was to characterize the bacterial and fungal microbiome in different types of environmental samples collected in studies of human health effects. We determined the composition of microbial communities present in home, school and outdoor air samples by amplifying and sequencing regions of rRNA genes from bacteria (16S) and fungi (18S and ITS). Samples for this pilot study included indoor settled dust (from both a Boston area birth cohort study on Home Allergens and Asthma (HAA) (n = 12) and a study of school exposures and asthma symptoms (SICAS) (n = 1)), as well as fine and coarse concentrated outdoor ambient particulate (CAP) samples (n = 9). Sequencing of amplified 16S, 18S, and ITS regions was performed on the Roche-454 Life Sciences Titanium pyrosequencing platform. Indoor dust samples were dominated by Gram-positive bacteria (Firmicutes and Actinobacteria); the most abundant bacterial genera were those related to human flora (Streptococcus, Staphylococcus, Corynebacterium and Lactobacillus). Outdoor CAPs were dominated by Gram-negative Proteobacteria from water and soil sources, in particular the genera Acidovorax, and Brevundimonas (which were present at very low levels or entirely absent in indoor dust). Phylum-level fungal distributions identified by 18S or ITS regions showed very similar findings: a predominance of Ascomycota in indoor dust and Basidiomycota in outdoor CAPs. ITS sequencing of fungal genera in indoor dust showed significant proportions of Aureobasidium and Leptosphaerulina along with some contribution from Cryptococcus, Epicoccum, Aspergillus and the human commensal Malassezia. ITS sequencing detected more than 70 fungal genera in indoor dust not observed by culture. Microbiome sequencing is feasible for different types of archived environmental samples (indoor dust, and low biomass air particulate samples), and offers the potential to study how whole communities of microbes (including unculturable taxa) influence human health.

  8. Characterization of the bacterial and fungal microbiome in indoor dust and outdoor air samples: a pilot study†

    PubMed Central

    Hanson, Blake; Zhou, Yanjiao; Bautista, Eddy J.; Urch, Bruce; Speck, Mary; Silverman, Frances; Muilenberg, Michael; Phipatanakul, Wanda; Weinstock, George; Sodergren, Erica; Gold, Diane R.; Sordillo, Joanne E.

    2016-01-01

    Environmental microbes have been associated with both protective and adverse health effects in children and adults. Epidemiological studies often rely on broad biomarkers of microbial exposure (i.e. endotoxin, 1→3, Beta-D glucan), but fail to identify the taxonomic composition of the microbial community. Our aim was to characterize the bacterial and fungal microbiome in different types of environmental samples collected in studies of human health effects. We determined the composition of microbial communities present in home, school and outdoor air samples by amplifying and sequencing regions of rRNA genes from bacteria (16S) and fungi (18S and ITS). Samples for this pilot study included indoor settled dust (from both a Boston area birth cohort study on Home Allergens and Asthma (HAA)(n=12) and a study of school exposures and asthma symptoms (SICAS) (n=1)), as well as fine and coarse concentrated outdoor ambient particulate (CAP) samples (n=9). Sequencing of amplified 16S, 18S, and ITS regions was performed on the Roche-454 Life Sciences Titanium pyrosequencing platform. Indoor dust samples were dominated by gram-positive bacteria (Firmicutes and Actinobacteria); the most abundant bacterial genera were those related to human flora (Streptococcus, Staphylococcus, Corynebacterium and Lactobacillus). Outdoor CAPs were dominated by gram-negative Proteobacteria from water and soil sources, in particular the genera Acidovorax, and Brevundimonas (which were present at very low levels or entirely absent in indoor dust). Phylum-level fungal distributions identified by 18S or ITS regions showed very similar findings: a predominance of Ascomycota in indoor dust and Basidiomycota in outdoor CAPs. ITS sequencing of fungal genera in indoor dust showed significant proportions of Aureobasidium and Leptosphaerulina along with some contribution from Cryptococcus, Epicoccum, Aspergillus and the human commensal Malassezia. ITS sequencing detected an additional 70 fungal genera in indoor dust not observed by culture. Microbiome sequencing is feasible for different types of archived environmental samples (indoor dust, and low biomass air particulate samples), and offers the potential to study how whole communities of microbes (including unculturable taxa) influence human health. PMID:27213188

  9. Semivolatile Endocrine-Disrupting Compounds in Paired Indoor and Outdoor Air in Two Northern California Communities

    PubMed Central

    2010-01-01

    Interest in the health effects of potential endocrine-disrupting compounds (EDCs) that are high production volume chemicals used in consumer products has made exposure assessment and source identification a priority. We collected paired indoor and outdoor air samples in 40 nonsmoking homes in urban, industrial Richmond, CA, and 10 in rural Bolinas, CA. Samples were analyzed by GC-MS for 104 analytes, including phthalates (11), alkylphenols (3), parabens (3), polybrominated diphenyl ether (PBDE) flame retardants (3), polychlorinated biphenyls (PCBs) (3), polycyclic aromatic hydrocarbons (PAHs) (24), pesticides (38), and phenolic compounds (19). We detected 39 analytes in outdoor air and 63 in indoor air. For many of the phenolic compounds, alkylphenols, phthalates, and PBDEs, these represent some of the first outdoor measures and the first analysis of the relative importance of indoor and outdoor sources in paired samples. Data demonstrate higher indoor concentrations for 32 analytes, suggesting primarily indoor sources, as compared with only 2 that were higher outdoors. Outdoor air concentrations were higher in Richmond than Bolinas for 3 phthalates, 10 PAHs, and o-phenylphenol, while indoor air levels were more similar between communities, except that differences observed outdoors were also seen indoors. Indoor concentrations of the most ubiquitous chemicals were generally correlated with each other (4-t-butylphenol, o-phenylphenol, nonylphenol, several phthalates, and methyl phenanthrenes; Kendall correlation coefficients 0.2−0.6, p < 0.05), indicating possible shared sources and highlighting the importance of considering mixtures in health studies. PMID:20681565

  10. Comparison of Air Impaction and Electrostatic Dust Collector Sampling Methods to Assess Airborne Fungal Contamination in Public Buildings.

    PubMed

    Normand, Anne-Cécile; Ranque, Stéphane; Cassagne, Carole; Gaudart, Jean; Sallah, Kankoé; Charpin, Denis-André; Piarroux, Renaud

    2016-03-01

    Many ailments can be linked to exposure to indoor airborne fungus. However, obtaining a precise measurement of airborne fungal levels is complicated partly due to indoor air fluctuations and non-standardized techniques. Electrostatic dust collector (EDC) sampling devices have been used to measure a wide range of airborne analytes, including endotoxins, allergens, β-glucans, and microbial DNA in various indoor environments. In contrast, viable mold contamination has only been assessed in highly contaminated environments such as farms and archive buildings. This study aimed to assess the use of EDCs, compared with repeated air-impactor measurements, to assess airborne viable fungal flora in moderately contaminated indoor environments. Indoor airborne fungal flora was cultured from EDCs and daily air-impaction samples collected in an office building and a daycare center. The quantitative fungal measurements obtained using a single EDC significantly correlated with the cumulative measurement of nine daily air impactions. Both methods enabled the assessment of fungal exposure, although a few differences were observed between the detected fungal species and the relative quantity of each species. EDCs were also used over a 32-month period to monitor indoor airborne fungal flora in a hospital office building, which enabled us to assess the impact of outdoor events (e.g. ground excavations) on the fungal flora levels on the indoor environment. In conclusion, EDC-based measurements provided a relatively accurate profile of the viable airborne flora present during a sampling period. In particular, EDCs provided a more representative assessment of fungal levels compared with single air-impactor sampling. The EDC technique is also simpler than performing repetitive air-impaction measures over the course of several consecutive days. EDC is a versatile tool for collecting airborne samples and was efficient for measuring mold levels in indoor environments. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  11. MANAGING SOURCES TO REDUCE RISK IN AND AROUND THE INDOOR ENVIRONMENT: IMPACT OF COATINGS ON DISLODGEABLE ARSENIC ON THE SURFACES OF CCA-TREATED WOOD

    EPA Science Inventory

    Due to the potential for ingestion of chromated copper arsenate (CCA) by the hand-to-mouth activities of young children who contact CCA treated wood, EPA has used wipe samples to study the potential benefits of paint-like coatings on CCA treated wood. Citizens who may be concern...

  12. Structure and properties of silk from the African wild silkmoth Gonometa postica reared indoors.

    PubMed

    Teshome, Addis; Raina, S K; Vollrath, Fritz

    2014-03-07

    African wild silkmoth, Gonometa postica Walker (Lepidoptera: Lasiocampidae), were reared indoors in order to examine the influence of rearing conditions on the structure and properties of silk cocoon shells and degummed fibers by using a scanning electron microscope, an Instron tensile tester, and a thermogravimetric analyzer. The cocoons reared indoors showed inferior quality in weight, length, width, and cocoon shell ratio compared to cocoons reared outdoors. There were no differences in cocoon shell and fiber surfaces and cross sectional structures. Cocoon shells were covered with calcium oxalate crystals with few visible fibers on their surface. Degummed fibers were smooth with minimum unfractured surfaces and globular to triangular cross sections. Indoor-reared cocoon shells had a significantly higher breaking strain, while the breaking stress was higher for cocoons reared outdoors. Fibers from indoor cocoons had a significantly higher breaking stress while outdoor fibers had higher breaking strain. Thermogravimetric analysis curves showed two main thermal reactions revealing the dehydration of water molecules and ir-reversible decomposition of the crystallites in both cocoons and fibers reared indoors and outdoors. Cocoon shells underwent additional peaks of decomposition with increased temperature. The total weight loss was higher for cocoon shells and degummed fibers from indoors. Rearing conditions (temperature and relative humidity), feeding method used, changes in total life span, days to molting, and spinning might have influenced the variation in the properties observed.The ecological and commercial significances of indoor rearing of G. posticaare discussed. This is an open access paper. We use the Creative Commons Attribution 3.0 license that permits unrestricted use, provided that the paper is properly attributed.

  13. METHODS TO CLASSIFY ENVIRONMENTAL SAMPLES BASED ON MOLD ANALYSES BY QPCR

    EPA Science Inventory

    Quantitative PCR (QPCR) analysis of molds in indoor environmental samples produces highly accurate speciation and enumeration data. In a number of studies, eighty of the most common or potentially problematic indoor molds were identified and quantified in dust samples from homes...

  14. Indoor Air Quality Investigations on Particulate Matter, Carbonyls, and Tobacco Specific Nitrosamines

    NASA Astrophysics Data System (ADS)

    Frey, Sarah E.

    Americans spend upwards of 90% of their time indoors, hence indoor air quality (IAQ) and the impact of IAQ on human health is a major public health concern. IAQ can be negatively impacted by outdoor pollution infiltrating indoors, the emission of indoor pollutants, indoor atmospheric chemistry and poor ventilation. Energy saving measures like retrofits to seal the building envelope to prevent the leakage of heated or cooled air will impact IAQ. However, existing studies have been inconclusive as to whether increased energy efficiency is leading to detrimental IAQ. In this work, field campaigns were conducted in apartment homes in Phoenix, Arizona to evaluate IAQ as it relates to particulate matter (PM), carbonyls, and tobacco specific nitrosamines (TSNA). To investigate the impacts of an energy efficiency retrofit on IAQ, indoor and outdoor air quality sampling was carried out at Sunnyslope Manor, a city-subsidized senior living apartment complex. Measured indoor formaldehyde levels before the building retrofit exceeded reference exposure limits, but in the long term follow-up sampling, indoor formaldehyde decreased for the entire study population by a statistically significant margin. Indoor PM levels were dominated by fine particles and showed a statistically significant decrease in the long term follow-up sampling within certain resident subpopulations (i.e. residents who reported smoking and residents who had lived longer at the apartment complex). Additionally, indoor glyoxal and methylglyoxal exceeded outdoor concentrations, with methylglyoxal being more prevalent pre-retrofit than glyoxal, suggesting different chemical pathways are involved. Indoor concentrations reported are larger than previous studies. TSNAs, specifically N'-nitrosonornicotine (NNN), 4-(methyl-nitrosamino)-4-(3-pyridyl)-butanal (NNA) and 4-(methylnitrosoamino)-1-(3-pyridyl)-1-butanone (NNK) were evaluated post-retrofit at Sunnyslope Manor. Of the units tested, 86% of the smoking units and 46% of the non-smoking units had traces of at least one of the nitrosamines.

  15. Formaldehyde gas inactivation of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surface materials.

    PubMed

    Rogers, J V; Choi, Y W; Richter, W R; Rudnicki, D C; Joseph, D W; Sabourin, C L K; Taylor, M L; Chang, J C S

    2007-10-01

    To evaluate the decontamination of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surface materials using formaldehyde gas. B. anthracis, B. subtilis, and G. stearothermophilus spores were dried on seven types of indoor surfaces and exposed to approx. 1100 ppm formaldehyde gas for 10 h. Formaldehyde exposure significantly decreased viable B. anthracis, B. subtilis, and G. stearothermophilus spores on all test materials. Significant differences were observed when comparing the reduction in viable spores of B. anthracis with B. subtilis (galvanized metal and painted wallboard paper) and G. stearothermophilus (industrial carpet and painted wallboard paper). Formaldehyde gas inactivated>or=50% of the biological indicators and spore strips (approx. 1x10(6) CFU) when analyzed after 1 and 7 days. Formaldehyde gas significantly reduced the number of viable spores on both porous and nonporous materials in which the two surrogates exhibited similar log reductions to that of B. anthracis on most test materials. These results provide new comparative information for the decontamination of B. anthracis spores with surrogates on indoor surfaces using formaldehyde gas.

  16. Aerosol Sampling Experiment on the International Space Station

    NASA Technical Reports Server (NTRS)

    Meyer, Marit E.

    2017-01-01

    The International Space Station (ISS) is a unique indoor environment which serves as both home and workplace to the astronaut crew. There is currently no particulate monitoring, although particulate matter requirements exist. An experiment to collect particles in the ISS cabin was conducted recently. Two different aerosol samplers were used for redundancy and to collect particles in two size ranges spanning from 10 nm to hundreds of micrometers. The Active Sampler is a battery operated thermophoretic sampler with an internal pump which draws in air and collects particles directly on a transmission electron microscope grid. This commercial-off-the-shelf device was modified for operation in low gravity. The Passive Sampler has five sampling surfaces which were exposed to air for different durations in order to collect at least one sample with an optimal quantity of particles for microscopy. These samples were returned to Earth for analysis with a variety of techniques to obtain long-term average concentrations and identify particle emission sources. Results are compared with the inventory of ISS aerosols which was created based on sparse data and the literature. The goal of the experiment is to obtain data on indoor aerosols on ISS for future particulate monitor design and development.

  17. Spatial and indoor/outdoor gradients in urban concentrations of ultrafine particles and PM2.5 mass and chemical components

    NASA Astrophysics Data System (ADS)

    Zauli Sajani, Stefano; Ricciardelli, Isabella; Trentini, Arianna; Bacco, Dimitri; Maccone, Claudio; Castellazzi, Silvia; Lauriola, Paolo; Poluzzi, Vanes; Harrison, Roy M.

    2015-02-01

    In order to investigate relationships between outdoor air pollution and concentrations indoors, a novel design of experiment has been conducted at two sites, one heavily trafficked and the other residential. The novel design aspect involves the introduction of air directly to the centre of an unoccupied room by use of a fan and duct giving a controlled air exchange rate and allowing an evaluation of particle losses purely due to uptake on indoor surfaces without the losses during penetration of the building envelope which affect most measurement programmes. The rooms were unoccupied and free of indoor sources, and consequently reductions in particle concentration were due to deposition processes within the room alone. Measurements were made of indoor and outdoor concentrations of PM2.5, major chemical components and particle number size distributions. Despite the absence of penetration losses, indoor to outdoor ratios were very similar to those in other studies showing that deposition to indoor surfaces is likely to be the major loss process for indoor air. The results demonstrated a dramatic loss of nitrate in the indoor atmosphere as well as a selective loss of particles in the size range below 50 nm, in comparison to coarser particles. Depletion of indoor particles was greater during a period of cold weather with higher outdoor concentrations probably due to an enhancement of semi-volatile materials in the outdoor particulate matter. Indoor/outdoor ratios for PM2.5 were generally higher at the trafficked site than the residential site, but for particle number were generally lower, reflecting the different chemical composition and size distributions of particles at the two sites.

  18. Comparisons of the dust/smoke particulate that settled inside the surrounding buildings and outside on the streets of southern New York City after the collapse of the World Trade Center, September 11, 2001.

    PubMed

    Yiin, Lih-Ming; Millette, James R; Vette, Alan; Ilacqua, Vito; Quan, Chunli; Gorczynski, John; Kendall, Michaela; Chen, Lung Chi; Weisel, Clifford P; Buckley, Brian; Yang, Ill; Lioy, Paul J

    2004-05-01

    The collapse of the World Trade Center (WTC) on September 11, 2001, generated large amounts of dust and smoke that settled in the surrounding indoor and outdoor environments in southern Manhattan. Sixteen dust samples were collected from undisturbed locations inside two uncleaned buildings that were adjacent to Ground Zero. These samples were analyzed for morphology, metals, and organic compounds, and the results were compared with the previously reported outdoor WTC dust/smoke results. We also analyzed seven additional dust samples provided by residents in the local neighborhoods. The morphologic analyses showed that the indoor WTC dust/smoke samples were similar to the outdoor WTC dust/smoke samples in composition and characteristics but with more than 50% mass in the <53-microm size fraction. This was in contrast to the outdoor samples that contained >50% of mass above >53 microm. Elemental analyses also showed the similarities, but at lower concentrations. Organic compounds present in the outdoor samples were also detected in the indoor samples. Conversely, the resident-provided convenience dust samples were different from either the WTC indoor or outdoor samples in composition and pH, indicating that they were not WTC-affected locations. In summary, the indoor dust/smoke was similar in concentration to the outdoor dust/smoke but had a greater percentage of mass <53 microm in diameter.

  19. Influence of indoor environmental factors on mass transfer parameters and concentrations of semi-volatile organic compounds.

    PubMed

    Wei, Wenjuan; Mandin, Corinne; Ramalho, Olivier

    2018-03-01

    Semi-volatile organic compounds (SVOCs) in indoor environments can partition among the gas phase, airborne particles, settled dust, and available surfaces. The mass transfer parameters of SVOCs, such as the mass transfer coefficient and the partition coefficient, are influenced by indoor environmental factors. Subsequently, indoor SVOC concentrations and thus occupant exposure can vary depending on environmental factors. In this review, the influence of six environmental factors, i.e., indoor temperature, humidity, ventilation, airborne particle concentration, source loading factor, and reactive chemistry, on the mass transfer parameters and indoor concentrations of SVOCs was analyzed and tentatively quantified. The results show that all mass transfer parameters vary depending on environmental factors. These variations are mostly characterized by empirical equations, particularly for humidity. Theoretical calculations of these parameters based on mass transfer mechanisms are available only for the emission of SVOCs from source surfaces when airborne particles are not present. All mass transfer parameters depend on the temperature. Humidity influences the partition of SVOCs among different phases and is associated with phthalate hydrolysis. Ventilation has a combined effect with the airborne particle concentration on SVOC emission and their mass transfer among different phases. Indoor chemical reactions can produce or eliminate SVOCs slowly. To better model the dynamic SVOC concentration indoors, the present review suggests studying the combined effect of environmental factors in real indoor environments. Moreover, interactions between indoor environmental factors and human activities and their influence on SVOC mass transfer processes should be considered. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. A test house study of pesticides and pesticide degradation products following an indoor application.

    PubMed

    Starr, J M; Gemma, A A; Graham, S E; Stout, D M

    2014-08-01

    Preexisting pesticide degradates are a concern for pesticide biomonitoring studies as exposure to them may result in overestimation of pesticide exposure. The purpose of this research was to determine whether there was significant formation and movement, of pesticide degradates over a 5-week period in a controlled indoor setting after insecticide application. Movement of the pesticides during the study was also evaluated. In a simulated crack and crevice application, commercially available formulations of fipronil, propoxur, cis/trans-permethrin, and cypermethrin were applied to a series of wooden slats affixed to the wall in one room of an unoccupied test house. Floor surface samples were collected through 35 days post-application. Concentrations of the pesticides and the following degradates were determined: 2-iso-propoxyphenol, cis/trans 3-(2,2-dichlorovinyl)-3-3-dimethyl-(1-cyclopropane) carboxylic acid, 3-phenoxybenzoic acid, fipronil sulfone, fipronil sulfide, and fipronil desulfinyl. Deltamethrin, which had never been applied, and chlorpyrifos, which had been applied several years earlier, and their degradation products, cis-3-(2,2-dibromovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid, and, 3,5,6-trichloro-2-pyridinol, respectively, were also measured. Propoxur was the only insecticide with mass movement away from the application site. There was no measurable formation or movement of the degradates. However, all degradates were present at low levels in the formulated product. These results indicate longitudinal repetitive sampling of indoor degradate levels during short-term studies, is unnecessary. Exposure to preexisting pesticide degradates may inflate estimates of exposure in biomonitoring studies where these compounds are used as biomarkers. To date, there is no published information on formation of pesticide degradates following an indoor application. We found that the study pesticides have low rates of degradation and are unlikely to be a significant factor affecting results of short-term (weeks) biomonitoring studies. Therefore, relatively few indoor samples are needed to estimate background levels of degradation products resulting from a recent pesticide application. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  1. Assessment of matrix effects on methyl benzoate, a potential biomarker for detection of outgassed semi-volatiles from mold in indoor building materials.

    PubMed

    Parkinson, Don-Roger; Churchill, Tonia J; Rolls, Wyn

    2008-11-01

    Methyl benzoate - as a biomarker for mold growth - was used as a specific target compound to indicate outgassed MVOC products from mold. Both real and surrogate samples were analyzed from a variety of matrices including: carpet, ceiling tiles, dried paint surfaces, wallboard and wallboard paper. Sampling parameters, including: desorption, extraction time, incubation temperature, pH, salt effects and spinning rate, were optimized. Results suggest that extraction and detection of methyl benzoate amongst other MVOCs can be accomplished cleanly by SPME-GC/MS methods. With detection limits (LOD = 1.5 ppb) and linearity (0.999) over a range of 100 ppm to 2 ppb, this work demonstrates that such a green technique can be contemplated for use in quick assessment or as part of an ongoing assessment strategy to detect mold growth in common indoor buildings and materials for both qualitative and quantitative determinations. Of importance, no matrix effects are observed under optimized extraction conditions.

  2. Influence of ammonia and carbon dioxide on the sorption of a basic organic pollutant to carpet and latex-painted gypsum board.

    PubMed

    Ongwandee, Maneerat; Morrison, Glenn C

    2008-08-01

    Sorptive interactions with indoor surfaces strongly influence indoor exposure to organic pollutants. Adsorption itself may be influenced by indoor levels of common indoor gases such as CO2, NH3, and H2O. We quantified sorption characteristics of trimethylamine (TMA) on carpet and painted wallboard, while challenging the surface with gas-phase CO2, NH3 and H2O. We show that the capacity of the carpet to sorb TMA, doubles when the CO2 mixing ratio is increased from 0 to 1000 ppm CO2 at 90% relative humidity. In contrast, NH3 decreases the surface capacity of both carpet and latex paint. Sorption of TMA to these indoor materials is primarily caused by interactions at one or more interfaces. Dissolution of TMA and aqueous acid-base chemistry appear to also contribute to the overall sorptive capacity of carpet at high relative humidity. The reduction in the distribution coefficient, k(e), in the presence of NH3 is explained by competition between TMA and NH3 molecules for sites on the substrates at low-to-medium relative humidity conditions.

  3. Nicotine as a Marker for Environmental Tobacco Smoke: Implications of Sorption on Indoor Surface Materials.

    PubMed

    Van Loy, Michael D; Nazaroff, William W; Daisey, Joan M

    1998-10-01

    Recently developed models and data describing the interactions of gas-phase semi-volatile organic compounds with indoor surfaces are employed to examine the effects of sorption on nicotine's suitability as an environmental tobacco smoke (ETS) marker. Using parameters from our studies of nicotine sorption on carpet, painted wallboard, and stainless steel and previously published data on ETS particle deposition, the dynamic behavior of nicotine was modeled in two different indoor environments: a house and a stainless steel chamber. The results show that apparently contradictory observations of nicotine's behavior in indoor air can be understood by considering the effects of sorption under different experimental conditions. In indoor environments in which smoking has occurred regularly for an extended period, the sorbed mass of nicotine is very large relative to the mass emitted by a single cigarette. The importance of nicotine adsorption relative to ventilation as a gas-phase removal mechanism is reduced. Where smoking occurs less regularly or the indoor surfaces are cleaned prior to smoking (as in a laboratory chamber), nicotine deposition is more significant. Nicotine concentrations closely track the levels of other ETS constituents in environments with habitual smoking if the data are averaged over a period significantly longer than the period between cigarette combustion episodes. However, nicotine is not a suitable tracer for predicting ETS exposures at fine time scales or in settings where smoking occurs infrequently and irregularly.

  4. Indoor Tanning Dependence in Young Adult Women.

    PubMed

    Mays, Darren; Atkins, Michael B; Ahn, Jaeil; Tercyak, Kenneth P

    2017-11-01

    Background: There is mounting evidence that young people can develop a dependence on indoor tanning, but research on factors associated with indoor tanning dependence remains limited. Methods: This cross-sectional study investigated factors associated with indoor tanning dependence in a community sample of 389 non-Hispanic white young adult women ages 18 to 30 who had indoor tanned ≥1 time in the past year. Participants completed measures of indoor tanning dependence, including the modified CAGE and modified Diagnostic and Statistical Manual for Mental Disorders-IV psychiatric screening assessments, indoor tanning behavior and beliefs, and behavioral and psychiatric comorbidity. Results: Overall, 22.6% of the sample screened positive for indoor tanning dependence. In multivariable analyses, indoor tanning dependence was associated with younger age of indoor tanning initiation [adjusted odds ratio (aOR) = 0.79; P = 0.017], indoor tanning ≥20 times in the past year (aOR = 3.03; P = 0.015), stronger beliefs about the benefits of tanning (aOR = 2.15; P = 0.004), greater perceived susceptibility to indoor tanning risks (aOR = 2.72; P < 0.001), stronger beliefs about physical appearance (aOR = 1.73; P = 0.037), and depressive symptoms (aOR = 3.79; P < 0.001). Conclusions: Indoor tanning dependence among young, non-Hispanic white women is associated with behaviors that increase the risk of skin cancer, beliefs favoring the perceived benefits of tanning, and comorbid risks such as stronger beliefs about physical appearance and depressed mood. Impact: Comprehensive skin cancer prevention efforts should address indoor tanning dependence among young women and its leading risk factors. Cancer Epidemiol Biomarkers Prev; 26(11); 1636-43. ©2017 AACR . ©2017 American Association for Cancer Research.

  5. Identification of possible sources of particulate matter in the personal cloud using SEM/EDX

    NASA Astrophysics Data System (ADS)

    Conner, Teri L.; Williams, Ronald W.

    2004-10-01

    The United States Environmental Protection Agency (US EPA) conducted the Baltimore Particulate Matter (PM) Epidemiology-Exposure Study of the Elderly during the summer of 1998. The study design included PM2.5 samples obtained from elderly (65+ years of age) retirement facility residents using personal exposure sampling devices. These sampling devices were also used to obtain PM2.5 samples at fixed locations within the personal monitoring subjects' apartments. Selected personal and apartment samples were examined using scanning electron microscopy with individual-particle X-ray analysis (SEM/EDX), providing a qualitative assessment of the chemical and physical characteristics of geological and trace element particles collected within these micro-environments at the retirement facility. This information was used to identify possible indoor source particles. The manual surveys of the personal samples revealed that some particles larger than 2.5 μm reached the filter surface. Using SEM/EDX, several particle types with possible indoor origins were identified. The Al-Zr-Cl particle is likely to have originated from a personal antiperspirant product. Particles with a talc or alumino-silicate composition point to cosmetics as a possible source. Large cadmium-containing particles were also found, which may indicate the use of art pigments or ceramic glazes, or emissions from television screen phosphors. A greater variety of particles was observed in a personal sample compared with its corresponding fixed-location apartment sample.

  6. Occurrence of endocrine-disrupting chemicals in indoor dust

    PubMed Central

    Hwang, Hyun-Min; Park, Eun-Kee; Young, Thomas M.; Hammock, Bruce D.

    2010-01-01

    Human exposure to indoor dust enriched with endocrine-disrupting chemicals released from numerous indoor sources has been a focus of increasing concern. Longer residence times and elevated contaminant concentrations in the indoor environment may increase chances of exposure to these contaminants by 1000-fold compared to outdoor exposure. To investigate the occurrence of semi-volatile endocrine-disrupting chemicals, including PBDEs (polybrominated diphenyl ethers), PCBs (polychlorinated biphenyls), phthalates, pyrethroids, DDT (dichlorodiphenyltrichloroethane) and its metabolites, and chlordanes, indoor dust samples were collected from household vacuum cleaner bags provided by 10 apartments and 1 community hall in Davis, California, USA. Chemical analyses show that all indoor dust samples are highly contaminated by target analytes measured in the present study. Di-(2-ethylhexyl)phthalate was the most abundant (104–7630 μg/g) in all samples and higher than other target analytes by 2 to 6 orders of magnitude. PBDEs were also found at high concentrations (1780–25,200 ng/g). Although the use of PCBs has been banned or restricted for decades, some samples had PCBs at levels that are considered to be concerns for human health, indicating that the potential risk posed by PCBs still remains high in the indoor environment, probably due to a lack of dissipation processes and continuous release from the sources. Although the use of some PBDEs is being phased out in some parts of the U.S., this trend may apply to PBDEs as well. We can anticipate that exposure to PBDEs will continue as long as the general public keeps using existing household items such as sofas, mattresses, and carpets that contain PBDEs. This study provides additional information that indoor dust is highly contaminated by persistent and endocrine-disrupting chemicals. PMID:18632138

  7. Alternative Methods for Assessing Contaminant Transport from the Vadose Zone to Indoor Air

    NASA Astrophysics Data System (ADS)

    Baylor, K. J.; Lee, A.; Reddy, P.; Plate, M.

    2010-12-01

    Vapor intrusion, which is the transport of contaminant vapors from groundwater and the vadose zone to indoor air, has emerged as a significant human health risk near hazardous waste sites. Volatile organic compounds (VOCs) such as trichloroethylene (TCE) and tetrachloroethylene (PCE) can volatilize from groundwater and from residual sources in the vadose zone and enter homes and commercial buildings through cracks in the slab, plumbing conduits, or other preferential pathways. Assessment of the vapor intrusion pathway typically requires collection of groundwater, soil gas, and indoor air samples, a process which can be expensive and time-consuming. We evaluated three alternative vapor intrusion assessment methods, including 1) use of radon as a surrogate for vapor intrusion, 2) use of pressure differential measurements between indoor/outdoor and indoor/subslab to assess the potential for vapor intrusion, and 3) use of passive, longer-duration sorbent methods to measure indoor air VOC concentrations. The primary test site, located approximately 30 miles south of San Francisco, was selected due to the presence of TCE (10 - 300 ug/L) in shallow groundwater (5 to 10 feet bgs). At this test site, we found that radon was not a suitable surrogate to asses vapor intrusion and that pressure differential measurements are challenging to implement and equipment-intensive. More significantly, we found that the passive, longer-duration sorbent methods are easy to deploy and compared well quantitatively with standard indoor air sampling methods. The sorbent technique is less than half the cost of typical indoor air methods, and also provides a longer duration sample, typically 3 to 14 days rather than 8 to 24 hours for standard methods. The passive sorbent methods can be a reliable, cost-effective, and easy way to sample for TCE, PCE and other VOCs as part of a vapor intrusion investigation.

  8. An Indoor Location-Based Control System Using Bluetooth Beacons for IoT Systems.

    PubMed

    Huh, Jun-Ho; Seo, Kyungryong

    2017-12-19

    The indoor location-based control system estimates the indoor position of a user to provide the service he/she requires. The major elements involved in the system are the localization server, service-provision client, user application positioning technology. The localization server controls access of terminal devices (e.g., Smart Phones and other wireless devices) to determine their locations within a specified space first and then the service-provision client initiates required services such as indoor navigation and monitoring/surveillance. The user application provides necessary data to let the server to localize the devices or allow the user to receive various services from the client. The major technological elements involved in this system are indoor space partition method, Bluetooth 4.0, RSSI (Received Signal Strength Indication) and trilateration. The system also employs the BLE communication technology when determining the position of the user in an indoor space. The position information obtained is then used to control a specific device(s). These technologies are fundamental in achieving a "Smart Living". An indoor location-based control system that provides services by estimating user's indoor locations has been implemented in this study (First scenario). The algorithm introduced in this study (Second scenario) is effective in extracting valid samples from the RSSI dataset but has it has some drawbacks as well. Although we used a range-average algorithm that measures the shortest distance, there are some limitations because the measurement results depend on the sample size and the sample efficiency depends on sampling speeds and environmental changes. However, the Bluetooth system can be implemented at a relatively low cost so that once the problem of precision is solved, it can be applied to various fields.

  9. An Indoor Location-Based Control System Using Bluetooth Beacons for IoT Systems

    PubMed Central

    Huh, Jun-Ho; Seo, Kyungryong

    2017-01-01

    The indoor location-based control system estimates the indoor position of a user to provide the service he/she requires. The major elements involved in the system are the localization server, service-provision client, user application positioning technology. The localization server controls access of terminal devices (e.g., Smart Phones and other wireless devices) to determine their locations within a specified space first and then the service-provision client initiates required services such as indoor navigation and monitoring/surveillance. The user application provides necessary data to let the server to localize the devices or allow the user to receive various services from the client. The major technological elements involved in this system are indoor space partition method, Bluetooth 4.0, RSSI (Received Signal Strength Indication) and trilateration. The system also employs the BLE communication technology when determining the position of the user in an indoor space. The position information obtained is then used to control a specific device(s). These technologies are fundamental in achieving a “Smart Living”. An indoor location-based control system that provides services by estimating user’s indoor locations has been implemented in this study (First scenario). The algorithm introduced in this study (Second scenario) is effective in extracting valid samples from the RSSI dataset but has it has some drawbacks as well. Although we used a range-average algorithm that measures the shortest distance, there are some limitations because the measurement results depend on the sample size and the sample efficiency depends on sampling speeds and environmental changes. However, the Bluetooth system can be implemented at a relatively low cost so that once the problem of precision is solved, it can be applied to various fields. PMID:29257044

  10. CHEMICAL AND PHYSICAL CHARACTERISTICS OF OUTDOOR, INDOOR, AND PERSONAL PARTICULATE AIR SAMPLES COLLECTED IN AND AROUND A RETIREMENT FACILITY

    EPA Science Inventory

    Residential, personal, indoor, and outdoor sampling of particulate matter was conducted at a retirement center in the Towson area of northern Baltimore County in 1998. Concurrent sampling was conducted at a central community site. Computer-controlled scanning electron microsco...

  11. CHEMICAL AND PHYSICAL CHARACTERIZATION OF INDOOR, OUTDOOR, AND PERSONAL SAMPLES COLLECTED IN AND AROUND A RETIREMENT FACILITY

    EPA Science Inventory

    Residential, personal, indoor, and outdoor sampling of particulate matter was conducted at a retirement center in the Towson area of northern Baltimore County in 1998. Concurrent sampling was conducted at a central community site. Computer-controlled scanning electron microsco...

  12. Experimental Measurements of the Water Evaporation Rate of a Physical Model

    NASA Astrophysics Data System (ADS)

    Turza, Róbert; Füri, Belo B.

    2017-03-01

    As the number of indoor swimming pools and wellness centers are currently growing, it is necessary to concentrate on the parameters of indoor environments. These parameters are necessary for the design of the HVAC systems that operate these premises. In indoor swimming-pool facilities, the energy demand is large due to ventilation losses from exhaust air. Since water evaporates from a pool's surface, exhaust air has a high water content and specific enthalpy. In this paper the results of the water evaporation rate measured from swimming pool surfaces at higher thermal water temperatures are described.

  13. Seasonal variation of indoor and outdoor air quality of nitrogen dioxide in homes with gas and electric stoves.

    PubMed

    Dėdelė, Audrius; Miškinytė, Auksė

    2016-09-01

    Indoor air pollution significantly influences personal exposure to air pollution and increases health risks. Nitrogen dioxide (NO2) is one of the major air pollutants, and therefore it is important to properly determine indoor concentration of this pollutant considering the fact that people spend most of their time inside. The aim of this study was to assess indoor and outdoor concentration of NO2 during each season; for this purpose, passive sampling was applied. We analyzed homes with gas and electric stoves to determine and compare the concentrations of NO2 in kitchen, living room, and bedroom microenvironments (MEs). The accuracy of passive sampling was evaluated by comparing the sampling results with the data from air quality monitoring stations. The highest indoor concentration of NO2 was observed in kitchen ME during the winter period, the median concentration being 28.4 μg m(-3). Indoor NO2 levels in homes with gas stoves were higher than outdoor levels during all seasons. The concentration of NO2 was by 2.5 times higher in kitchen MEs with gas stoves than with electric stoves. This study showed that the concentration of NO2 in indoor MEs mainly depended on the stove type used in the kitchen. Homes with gas stoves had significantly higher levels of NO2 in all indoor MEs compared with homes where electric stoves were used.

  14. Seasonal and Spatial Variations of Indoor Pollen in a Hospital

    PubMed Central

    Tormo-Molina, Rafael; Gonzalo-Garijo, Ángela; Silva-Palacios, Inmaculada; Fernández-Rodríguez, Santiago

    2009-01-01

    The airborne indoor pollen in a hospital of Badajoz (Spain) was monitored over two years using a personal Burkard sampler. The air was sampled in four places indoors—one closed room and one open ward on each of the ground and the third floors—and one place outdoors at the entrance to the hospital. The results were compared with data from a continuous volumetric sampler. While 32 pollen types were identified, nearly 75% of the total counts were represented by just five of them. These were: Quercus, Cupressaceae, Poaceae, Olea, and Plantago. The average indoor concentration was 25.2 grains/m3, and the average indoor/outdoor ratio was 0.27. A strong seasonal pattern was found, with the highest levels in spring and winter, and the indoor concentrations were correlated with the outdoor one. Indoor air movement led to great homogeneity in the airborne pollen presence: the indoor results were not influenced by whether or not the room was isolated, the floor level, or the number of people in or transiting the site during sampling. The presence of ornamental vegetation in the area surrounding the building affected the indoor counts directly as sources of the pollen. PMID:20049254

  15. Yield and turnover of illicit indoor cannabis (Cannabis spp.) plantations in Belgium.

    PubMed

    Vanhove, Wouter; Surmont, Tim; Van Damme, Patrick; De Ruyver, Brice

    2012-07-10

    In prosecution, Belgian judiciary currently uses outdated yield figures (28.1g per plant, sold at € 3/g at grower level) for fining illicit indoor cannabis plantations. Using state-of-the-art cultivation techniques, our growth experiments showed that yield is better expressed in g/m(2) cultivated surface area rather than in g per plant, and that yield varies significantly between different cannabis strains. It was found that the lower-bound of the one-sided 95% confidence interval of the yield of an indoor cannabis plantation can be set at 575 g/m(2). Prices and pricing mechanisms were investigated using interviews with respondents selected through snowball sampling. Results reveal that (i) the Belgian cannabis market chain is highly complex; (ii) unit prices are predominantly determined by transaction sizes; but also (iii) a set of product- and socially-related price-fixing mechanisms have an equally important role. At grower level, respondents reported prices for 1 g of dry cannabis buds to range € 3.00-4.25. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  16. Comparison of mold concentrations quantified by MSQPCR in indoor and outdoor air sampled simultaneously

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meklin, Teija; Reponen, Tina; McKinstry, Craig A.

    Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of 36 mold species in dust and in indoor and in outdoor air samples that were taken simultaneously in 17 homes in Cincinnati with no-known water damage. The total spore concentrations in the indoor (I) and outdoor (O) air samples were statistically significantly different and the concentrations in the three sample types of many of the individual species were significantly different (p < 0.05 based on the Wilcoxon Signed Rank Test). The I/O ratios of the averages or geometric means of the individual species were generally less than 1;more » but these I/O ratios were quite variable ranging from 0.03 for A. sydowii to 1.2 for Acremonium strictum. There were no significant correlations for the 36 specific mold concentrations between the dust samples and the indoor or outdoor air samples (based on the Spearman’s Rho test). The indoor and outdoor air concentrations of 32 of the species were not correlated. Only Aspergillus penicillioides, C. cladosporioides types 1 and 2 and C. herbarum had sufficient data to estimate a correlation at rho > 0.5 with signicance (p < 0.05) In six of these homes, a previous dust sample had been collected and analyzed 2 years earlier. The ERMI© values for the dust samples taken in the same home two years apart were not significantly different (p=0.22) based on Wilcoxon Signed Rank Test.« less

  17. Biodiversity and concentrations of airborne fungi in large US office buildings from the BASE study

    NASA Astrophysics Data System (ADS)

    Tsai, Feng C.; Macher, Janet M.; Hung, Yun-Yi

    The Building Assessment Survey and Evaluation (BASE) study measured baseline concentrations of airborne fungi in 100 representative US office buildings in 1994-1998. Multiple samples for different sampling durations, sites, and times of the day were aggregated into building-wide indoor and outdoor average concentrations. Fungal concentrations were compared between locations (indoor vs. outdoor), sampling and analytical methods (culture vs. microscopy), and season (summer vs. winter). The arithmetic means (standard deviations) of the indoor/outdoor concentrations of culturable fungi and fungal spores were 100/680 (230/840) CFUm-3 and 270/6540 (1190/6780) sporem-3, respectively. Although fewer groups were observed indoors than outdoors, at lower average concentrations (except in two buildings), site-specific and building-wide indoor measurements had higher coefficients of variation. More groups were seen in summer, and aggregated concentrations tended to be higher than in winter except for culturable Aureobasidium spp. and Botrytis spp. outdoors and non-sporulating fungi in both locations. Rankings of the predominant fungi identified by both methods were similar, but overall indoor and outdoor spore concentrations were approximately 3 and 10 times higher, respectively, than concentrations of culturable fungi. In the 44 buildings with both measurements, the indoor and outdoor total culturable fungi to fungal spore ratios (total C/S ratios) were 1.27 and 0.25, with opposite seasonal patterns. The indoor C/S ratio was higher in summer than in winter (1.47 vs. 0.86; N=29 and 15, respectively), but the outdoor ratio was lower in summer (0.19 vs. 0.36, respectively). Comparison of the number of different fungal groups and individual occurrence in buildings and samples indicated that the outdoor environment and summer season were more diverse, but the proportional contributions of the groups were very similar suggesting that the indoor and outdoor environments were related as were summer and winter seasons for each location. The extreme (e.g., 90th percentile) indoor concentrations ( 200CFUm-3 and 210sporem-3) may provide reference values for non-complaint US office environments.

  18. RESIDENTIAL INDOOR EXPOSURES OF CHILDREN TO PESTICIDES FOLLOWING LAWN APPLICATIONS

    EPA Science Inventory

    Methods have been developed to estimate children's residential exposures to pesticide residues and applied in a small field study of indoor exposures resulting from the intrusion of lawn-applied herbicide into the home. Sampling methods included size-selective indoor air sampli...

  19. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF INDOOR FLOOR SAMPLES AND POST FIELD SAMPLE HANDLING (UA-F-7.1)

    EPA Science Inventory

    The purpose of this SOP is to establish a uniform procedure for the collection of indoor floor dust samples in the field. This procedure was followed to ensure consistent data retrieval of dust samples during the Arizona NHEXAS project and the "Border" study. Keywords: field; va...

  20. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FIXED SITE INDOOR AND OUTDOOR AIR SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.12)

    EPA Science Inventory

    This SOP describes the procedures to set up, calibrate, initiate and terminate air sampling for persistent organic pollutants. This method is used to sample air, indoors and outdoors, at homes and at day care centers over a 48-hr period.

  1. Emerging developments in the standardized chemical characterization of indoor air quality.

    PubMed

    Nehr, Sascha; Hösen, Elisabeth; Tanabe, Shin-Ichi

    2017-01-01

    Despite the fact that the special characteristics of indoor air pollution make closed environments quite different from outdoor environments, the conceptual ideas for assessing air quality indoors and outdoors are similar. Therefore, the elaboration of International Standards for air quality characterization in view of controlling indoor air quality should resort to this common basis. In this short review we describe the possibilities of standardization of tools dedicated to indoor air quality characterization with a focus on the tools permitting to study the indoor air chemistry. The link between indoor exposure and health as well as the critical processes driving the indoor air quality are introduced. Available International Standards for the assessment of indoor air quality are depicted. The standards comprise requirements for the sampling on site, the analytical procedures, and the determination of material emissions. To date, these standardized procedures assure that indoor air, settled dust and material samples are analyzed in a comparable manner. However, existing International Standards exclusively specify conventional, event-driven target-screening using discontinuous measurement methods for long-lived pollutants. Therefore, this review draws a parallel between physico-chemical processes in indoor and outdoor environments. The achievements in atmospheric sciences also improve our understanding of indoor environments. The community of atmospheric scientists can be both ideal and supporter for researchers in the area of indoor air quality characterization. This short review concludes with propositions for future standardization activities for the chemical characterization of indoor air quality. Future standardization efforts should focus on: (i) the elaboration of standardized measurement methods and measurement strategies for online monitoring of long-lived and short-lived pollutants, (ii) the assessment of the potential and the limitations of non-target screening, (iii) the paradigm shift from event-driven investigations to systematic approaches to characterize indoor environments, and (iv) the development of tools for policy implementation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Evaluation of hirst-type spore trap to monitor environmental fungal load in hospital

    PubMed Central

    Gustin, Marie-Paule; Cassier, Pierre; Loeffert, Sophie Tiphaine; Thibaudon, Michel; Bénet, Thomas; Vanhems, Philippe

    2017-01-01

    The main purpose was to validate the use of outdoor-indoor volumetric impaction sampler with Hirst-type spore traps (HTSTs) to continuously monitor fungal load in order to prevent invasive fungal infections during major structural work in hospital settings. For 4 weeks, outdoor fungal loads were quantified continuously by 3 HTSTs. Indoor air was sampled by both HTST and viable impaction sampler. Results were expressed as particles/m3 (HTST) or colony-forming units (CFU)/m3 (biocollector). Paired comparisons by day were made with Wilcoxon’s paired signed-rank test or paired Student’s t-test as appropriate. Paired airborne spore levels were correlated 2 by 2, after log-transformation with Pearson’s cross-correlation. Concordance was calculated with kappa coefficient (κ). Median total fungal loads (TFLs) sampled by the 3 outdoor HTSTs were 3,025.0, 3,287.5 and 3,625.0 particles/m3 (P = 0.6, 0.6 and 0.3).—Concordance between Aspergillaceae fungal loads (AFLs, including Aspergillus spp. + Penicillium spp.) was low (κ = 0.2). A low positive correlation was found between TFLs sampled with outdoor HTST and indoor HTST with applying a 4-hour time lag, r = 0.30, 95% CI (0.23–0.43), P<0.001. In indoor air, Aspergillus spp. were detected by the viable impaction sampler on 63.1% of the samples, whereas AFLs were found by HTST-I on only 3.6% of the samples. Concordance between Aspergillus spp. loads and AFLs sampled with the 2 methods was very low (κ = 0.1). This study showed a 4-hour time lag between increase of outdoor and indoor TFLs, possibly due to insulation and aeraulic flow of the building. Outdoor HTSTs may permit to quickly identify (after 48 hours) time periods with high outdoor fungal loads. An identified drawback is that a too low sample area read did not seem to enable detection of Aspergillaceae spores efficiently. Indoor HTSTs may not be recommended at this time, and outdoor HTSTs need further study. Air sampling by viable impaction sampler remains the reference tool for quantifying fungal contamination of indoor air in hospitals. PMID:28486534

  3. Evaluation of hirst-type spore trap to monitor environmental fungal load in hospital.

    PubMed

    Dananché, Cédric; Gustin, Marie-Paule; Cassier, Pierre; Loeffert, Sophie Tiphaine; Thibaudon, Michel; Bénet, Thomas; Vanhems, Philippe

    2017-01-01

    The main purpose was to validate the use of outdoor-indoor volumetric impaction sampler with Hirst-type spore traps (HTSTs) to continuously monitor fungal load in order to prevent invasive fungal infections during major structural work in hospital settings. For 4 weeks, outdoor fungal loads were quantified continuously by 3 HTSTs. Indoor air was sampled by both HTST and viable impaction sampler. Results were expressed as particles/m3 (HTST) or colony-forming units (CFU)/m3 (biocollector). Paired comparisons by day were made with Wilcoxon's paired signed-rank test or paired Student's t-test as appropriate. Paired airborne spore levels were correlated 2 by 2, after log-transformation with Pearson's cross-correlation. Concordance was calculated with kappa coefficient (κ). Median total fungal loads (TFLs) sampled by the 3 outdoor HTSTs were 3,025.0, 3,287.5 and 3,625.0 particles/m3 (P = 0.6, 0.6 and 0.3).-Concordance between Aspergillaceae fungal loads (AFLs, including Aspergillus spp. + Penicillium spp.) was low (κ = 0.2). A low positive correlation was found between TFLs sampled with outdoor HTST and indoor HTST with applying a 4-hour time lag, r = 0.30, 95% CI (0.23-0.43), P<0.001. In indoor air, Aspergillus spp. were detected by the viable impaction sampler on 63.1% of the samples, whereas AFLs were found by HTST-I on only 3.6% of the samples. Concordance between Aspergillus spp. loads and AFLs sampled with the 2 methods was very low (κ = 0.1). This study showed a 4-hour time lag between increase of outdoor and indoor TFLs, possibly due to insulation and aeraulic flow of the building. Outdoor HTSTs may permit to quickly identify (after 48 hours) time periods with high outdoor fungal loads. An identified drawback is that a too low sample area read did not seem to enable detection of Aspergillaceae spores efficiently. Indoor HTSTs may not be recommended at this time, and outdoor HTSTs need further study. Air sampling by viable impaction sampler remains the reference tool for quantifying fungal contamination of indoor air in hospitals.

  4. Analysis of Personal and Home Characteristics Associated with the Elemental Composition of PM2.5 in Indoor, Outdoor, and Personal Air in the RIOPA Study.

    PubMed

    Ryan, Patrick H; Brokamp, Cole; Fan, Zhi-Hua; Rao, M B

    2015-12-01

    The complex mixture of chemicals and elements that constitute particulate matter (PM*) varies by season and geographic location because source contributors differ over time and place. The composition of PM having an aerodynamic diameter < 2.5 μm (PM2.5) is hypothesized to be responsible, in part, for its toxicity. Epidemiologic studies have identified specific components and sources of PM2.5 that are associated with adverse health outcomes. The majority of these studies use measures of outdoor concentrations obtained from one or a few central monitoring sites as a surrogate for measures of personal exposure. Personal PM2.5 (and its elemental composition), however, may be different from the PM2.5 measured at stationary outdoor sites. The objectives of this study were (1) to describe the relationships between the concentrations of various elements in indoor, outdoor, and personal PM2.5 samples, (2) to identify groups of individuals with similar exposures to mixtures of elements in personal PM2.5 and to examine personal and home characteristics of these groups, and (3) to evaluate whether concentrations of elements from outdoor PM2.5 samples are appropriate surrogates for personal exposure to PM2.5 and its elements and whether indoor PM2.5 concentrations and information about home characteristics improve the prediction of personal exposure. The objectives of the study were addressed using data collected as part of the Relationships of Indoor, Outdoor, and Personal Air (RIOPA) study. The RIOPA study has previously measured the mass concentrations of PM2.5 and its elemental constituents during 48-hour concurrent indoor, outdoor (directly outside the home), and personal samplings in three urban areas (Los Angeles, California; Houston, Texas; and Elizabeth, New Jersey). The resulting data and information about personal and home characteristics (including air-conditioning use, nearby emission sources, time spent indoors, census-tract geography, air-exchange rates, and other information) for each RIOPA participant were downloaded from the RIOPA study database. We performed three sets of analyses to address the study aims. First, we conducted descriptive analyses to describe the relationships between elemental concentrations in the concurrently gathered indoor, outdoor, and personal air samples. We assessed the correlation between personal exposure and indoor concentrations as well as personal exposure and outdoor concentrations of each element and calculated ratios between them. In addition, we performed principal component analysis (PCA) and calculated principal component scores (PCSs) to examine the heterogeneity of the elemental composition and then tested whether the mixture of elements in indoor, outdoor, and personal PM2.5 was significantly different within each study site and across study sites. Secondly, we performed model-based clustering analysis to group RIOPA participants with similar exposures to mixtures of elements in personal PM2.5. We examined the association between cluster membership and the concentrations of elements in indoor and outdoor PM2.5 samples and personal and home characteristics. Finally, we developed a series of linear regression models and random forest models to examine the association between personal exposure to elements in PM2.5 and (1) outdoor measurements, (2) outdoor and indoor measurements, and (3) outdoor and indoor measurements and home characteristics. As we developed each model, the improvement in prediction of personal exposure when including additional information was assessed. Personal exposures to PM2.5 and to most elements were significantly correlated with both indoor and outdoor concentrations, although concentrations in personal samples frequently exceeded those of indoor and outdoor samples. In general, for most PM2.5 elements indoor concentrations were more highly correlated with personal exposure than were outdoor concentrations. PCA showed that the mixture of elements in indoor, outdoor, and personal PM2.5 varied significantly across sample types within each study site and also across study sites within each sample type. Using model-based clustering, we identified seven clusters of RIOPA participants whose personal PM2.5 samples had similar patterns of elemental composition. Using this approach, subsets of RIOPA participants were identified whose personal exposures to PM2.5 (and its elements) were significantly higher than their indoor and outdoor concentrations (and vice versa). The results of linear and random forest regression models were consistent with our correlation analyses and demonstrated that (1) indoor concentrations were more significantly associated with personal exposure than were outdoor concentrations and (2) participant reports of time spent at their home significantly modified many of the associations between indoor and personal concentrations. In linear regression models, the inclusion of indoor concentrations significantly improved the prediction of personal exposures to Ba, Ca, Cl, Cu, K, Sn, Sr, V, and Zn compared with the use of outdoor elemental concentrations alone. Including additional information on personal and home characteristics improved the prediction for only one element, Pb. Our results support the use of outdoor monitoring sites as surrogates of personal exposure for a limited number of individual elements associated with long-range transport and with a few local or indoor sources. Based on our PCA and clustering analyses, we concluded that the overall elemental composition of PM2.5 obtained at outdoor monitoring sites may not accurately represent the elemental composition of personal PM2.5. Although the data used in these analyses compared outdoor PM2.5 composition collected at the home with indoor and personal samples, our results imply that studies examining the complete elemental composition of PM2.5 should be cautious about using data from central outdoor monitoring sites because of the potential for exposure misclassification. The inclusion of personal and home characteristics only marginally improved the prediction of personal exposure for a small number of elements in PM2.5. We concluded that the additional cost and burden of indoor and personal sampling may be justified for studies examining elements because neither outdoor monitoring nor questionnaire data on home and personal characteristics were able to represent adequately the overall elemental composition of personal PM2.5.

  5. Improving the indoor air quality by using a surface emissions trap

    NASA Astrophysics Data System (ADS)

    Markowicz, Pawel; Larsson, Lennart

    2015-04-01

    The surface emissions trap, an adsorption cloth developed for reducing emissions of volatile organic compounds and particulate matter from surfaces while allowing evaporation of moisture, was used to improve the indoor air quality of a school building with elevated air concentrations of 2-ethyl-1-hexanol. An improvement of the perceived air quality was noticed a few days after the device had been attached on the PVC flooring. In parallel, decreased air concentrations of 2-ethyl-1-hexanol were found as well as a linear increase of the amounts of the same compound adsorbed on the installed cloth as observed up to 13 months after installation. Laboratory studies revealed that the performance of the device is not affected by differences in RH (35-85%), temperature (30-40 °C) or by accelerated aging simulating up to 10 years product lifetime, and, from a blinded exposure test, that the device efficiently blocks chemical odors. This study suggests that the device may represent a fast and efficient means of restoring the indoor air quality in a building e.g. after water damage leading to irritating and potentially harmful emissions from building material surfaces indoors.

  6. Organophosphate flame retardants and plasticizers in indoor dust, air and window wipes in newly built low-energy preschools.

    PubMed

    Persson, Josefin; Wang, Thanh; Hagberg, Jessika

    2018-07-01

    The construction of extremely airtight and energy efficient low-energy buildings is achieved by using functional building materials, such as age-resistant plastics, insulation, adhesives, and sealants. Additives such as organophosphate flame retardants (OPFRs) can be added to some of these building materials as flame retardants and plasticizers. Some OPFRs are considered persistent, bioaccumulative and toxic. Therefore, in this pilot study, the occurrence and distribution of nine OPFRs were determined for dust, air, and window wipe samples collected in newly built low-energy preschools with and without environmental certifications. Tris(1,3-dichloroisopropyl) phosphate (TDCIPP) and triphenyl phosphate (TPHP) were detected in all indoor dust samples at concentrations ranging from 0.014 to 10μg/g and 0.0069 to 79μg/g, respectively. Only six OPFRs (predominantly chlorinated OPFRs) were detected in the indoor air. All nine OPFRs were found on the window surfaces and the highest concentrations, which occurred in the reference preschool, were measured for 2-ethylhexyl diphenyl phosphate (EHDPP) (maximum concentration: 1500ng/m 2 ). Interestingly, the OPFR levels in the environmental certified low-energy preschools were lower than those in the reference preschool and the non-certified low-energy preschool, probably attributed to the usage of environmental friendly and low-emitting building materials, interior decorations, and consumer products. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Quantitative filter forensics for indoor particle sampling.

    PubMed

    Haaland, D; Siegel, J A

    2017-03-01

    Filter forensics is a promising indoor air investigation technique involving the analysis of dust which has collected on filters in central forced-air heating, ventilation, and air conditioning (HVAC) or portable systems to determine the presence of indoor particle-bound contaminants. In this study, we summarize past filter forensics research to explore what it reveals about the sampling technique and the indoor environment. There are 60 investigations in the literature that have used this sampling technique for a variety of biotic and abiotic contaminants. Many studies identified differences between contaminant concentrations in different buildings using this technique. Based on this literature review, we identified a lack of quantification as a gap in the past literature. Accordingly, we propose an approach to quantitatively link contaminants extracted from HVAC filter dust to time-averaged integrated air concentrations. This quantitative filter forensics approach has great potential to measure indoor air concentrations of a wide variety of particle-bound contaminants. Future studies directly comparing quantitative filter forensics to alternative sampling techniques are required to fully assess this approach, but analysis of past research suggests the enormous possibility of this approach. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Deteriorated housing contributes to high cockroach allergen levels in inner-city households.

    PubMed Central

    Rauh, Virginia A; Chew, Ginger R; Garfinkel, Robin S

    2002-01-01

    The high prevalence of childhood asthma in low-income, inner-city populations is not fully understood but has been at least partly attributed to the disproportionate exposures associated with socioeconomic disadvantage. The contribution of indoor allergens to asthma is well documented, but links between socioeconomic disadvantage and indoor allergen levels are not clear. We investigated levels of cockroach allergens (Bla g 2) in a sample of 132 Dominican or African American low-income households with young children in northern Manhattan in New York City (40% were receiving public assistance) to determine whether the distribution of allergens is a function of housing deterioration. Deterioration was measured by the presence and number of physical housing problems (holes in the ceilings and walls, water damage, etc.). More than 50% of the sample had two or more types of housing dilapidation, and 67% of the sample reported cockroach sightings in their homes. Samples of dust were collected from kitchen and bedroom surfaces. We hypothesized that the greater the dilapidation, the higher the allergen levels, independent of income, sociocultural factors, and pest-control methods. In addition, we hypothesized that the homes of families characterized by frequent moves (23.5%) would have higher allergen levels than more stable families. Results showed significant positive associations between housing deterioration and allergen levels in kitchens, after adjusting for income and ethnicity, with independent effects of residential stability (p< 0.05). Bedroom allergen levels were associated with housing instability (p < 0.01) and ethnicity (p< 0.01). Findings demonstrated that indoor household allergen levels are related to degree of household disrepair, after adjusting for individual family attributes, suggesting that social-structural aspects of housing may be appropriate targets for public health interventions designed to reduce allergen exposure. PMID:11929744

  9. Light-induced nitrous acid (HONO) production from NO2 heterogeneous reactions on household chemicals

    NASA Astrophysics Data System (ADS)

    Gómez Alvarez, Elena; Sörgel, Matthias; Gligorovski, Sasho; Bassil, Sabina; Bartolomei, Vincent; Coulomb, Bruno; Zetzsch, Cornelius; Wortham, Henri

    2014-10-01

    Nitrous acid (HONO) can be generated in various indoor environments directly during combustion processes or indirectly via heterogeneous NO2 reactions with water adsorbed layers on diverse surfaces. Indoors not only the concentrations of NO2 are higher but the surface to volume (S/V) ratios are larger and therefore the potential of HONO production is significantly elevated compared to outdoors. It has been claimed that the UV solar light is largely attenuated indoors. Here, we show that solar light (λ > 340 nm) penetrates indoors and can influence the heterogeneous reactions of gas-phase NO2 with various household surfaces. The NO2 to HONO conversion mediated by light on surfaces covered with domestic chemicals has been determined at atmospherically relevant conditions i.e. 50 ppb NO2 and 50% RH. The formation rates of HONO were enhanced in presence of light for all the studied surfaces and are determined in the following order: 1.3·109 molecules cm-2 s-1 for borosilicate glass, 1.7·109 molecules cm-2 s-1 for bathroom cleaner, 1.0·1010 molecules cm-2 s-1 on alkaline detergent (floor cleaner), 1.3·1010 molecules cm-2 s-1 for white wall paint and 2.7·1010 molecules cm-2 s-1 for lacquer. These results highlight the potential of household chemicals, used for cleaning purposes to generate HONO indoors through light-enhanced NO2 heterogeneous reactions. The results obtained have been applied to predict the timely evolution of HONO in a real indoor environment using a dynamic mass balance model. A steady state mixing ratio of HONO has been estimated at 1.6 ppb assuming a contribution from glass, paint and lacquer and considering the photolysis of HONO as the most important loss process.

  10. Very volatile organic compounds: an understudied class of indoor air pollutants.

    PubMed

    Salthammer, T

    2016-02-01

    Very volatile organic compounds (VVOCs), as categorized by the WHO, are an important subgroup of indoor pollutants and cover a wide spectrum of chemical substances. Some VVOCs are components of products commonly used indoors, some result from chemical reactions and some are reactive precursors of secondary products. Nevertheless, there is still no clear and internationally accepted definition of VVOCs. Current approaches are based on the boiling point, and the saturation vapor pressure or refer to analytical procedures. A significant problem is that many airborne VVOCs cannot be routinely analyzed by the usually applied technique of sampling on Tenax TA® followed by thermal desorption GC/MS or by DNPH-sampling/HPLC/UV. Some VVOCs are therefore often neglected in indoor-related studies. However, VVOCs are of high significance for indoor air quality assessment and there is need for their broader consideration in measurement campaigns and material emission testing. © 2014 The Authors. Indoor Air published by John Wiley & Sons Ltd.

  11. US EPA BASE Study Standard Operating Procedure for Sampling of Particulates

    EPA Pesticide Factsheets

    The objective of the procedure described is to collect a sample of particles of respirable and inhalable size (approx. 0.1 to 10 microns in diameter) from indoor air and from the outdoor air supplied to the indoor space tested.

  12. Using big data from air quality monitors to evaluate indoor PM2.5 exposure in buildings: Case study in Beijing.

    PubMed

    Zuo, JinXing; Ji, Wei; Ben, YuJie; Hassan, Muhammad Azher; Fan, WenHong; Bates, Liam; Dong, ZhaoMin

    2018-05-19

    Due to time- and expense- consuming of conventional indoor PM 2.5 (particulate matter with aerodynamic diameter of less than 2.5 μm) sampling, the sample size in previous studies was generally small, which leaded to high heterogeneity in indoor PM 2.5 exposure assessment. Based on 4403 indoor air monitors in Beijing, this study evaluated indoor PM 2.5 exposure from 15th March 2016 to 14th March 2017. Indoor PM 2.5 concentration in Beijing was estimated to be 38.6 ± 18.4 μg/m 3 . Specifically, the concentration in non-heating season was 34.9 ± 15.8 μg/m 3 , which was 24% lower than that in heating season (46.1 ± 21.2 μg/m 3 ). A significant correlation between indoor and ambient PM 2.5 (p < 0.05) was evident with an infiltration factor of 0.21, and the ambient PM 2.5 contributed approximately 52% and 42% to indoor PM 2.5 for non-heating and heating seasons, respectively. Meanwhile, the mean indoor/outdoor (I/O) ratio was estimated to be 0.73 ± 0.54. Finally, the adjusted PM 2.5 exposure level integrating the indoor and outdoor impact was calculated to be 46.8 ± 27.4 μg/m 3 , which was approximately 42% lower than estimation only relied on ambient PM 2.5 concentration. This study is the first attempt to employ big data from commercial air monitors to evaluate indoor PM 2.5 exposure and risk in Beijing, which may be instrumental to indoor PM 2.5 pollution control. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Organic compounds in indoor air—their relevance for perceived indoor air quality?

    NASA Astrophysics Data System (ADS)

    Wolkoff, Peder; Nielsen, Gunnar D.

    It is generally believed that indoor air pollution, one way or another may cause indoor air complaints. However, any association between volatile organic compounds (VOCs) concentrations and increase of indoor climate complaints, like the sick-building syndrome symptoms, is not straightforward. The reported symptom rates of, in particular, eye and upper airway irritation cannot generally be explained by our present knowledge of common chemically non-reactive VOCs measured indoors. Recently, experimental evidence has shown those chemical reactions between ozone (either with or without nitrogen dioxide) and unsaturated organic compounds (e.g. from citrus and pine oils) produce strong eye and airway irritating species. These have not yet been well characterised by conventional sampling and analytical techniques. The chemical reactions can occur indoors, and there is indirect evidence that they are associated with eye and airway irritation. However, many other volatile and non-volatile organic compounds have not generally been measured which could equally well have potent biological effects and cause an increase of complaint rates, and posses a health/comfort risk. As a consequence, it is recommended to use a broader analytical window of organic compounds than the classic VOC window as defined by the World Health Organisation. It may include hitherto not yet sampled or identified intermediary species (e.g., radicals, hydroperoxides and ionic compounds like detergents) as well as species deposited onto particles. Additionally, sampling strategies including emission testing of building products should carefully be linked to the measurement of organic compounds that are expected, based on the best available toxicological knowledge, to have biological effects at indoor concentrations.

  14. Bio-template-assisted synthesis of hierarchically hollow SiO2 microtubes and their enhanced formaldehyde adsorption performance

    NASA Astrophysics Data System (ADS)

    Le, Yao; Guo, Daipeng; Cheng, Bei; Yu, Jiaguo

    2013-06-01

    The indoor air quality is crucial for human health, taking into account that people often spend more than 80% of their time in houses, offices and cars. Formaldehyde (HCHO) is a major pollutant and long-term exposure to HCHO may cause health problems such as nasal tumors and skin irritation. In this work, for the first time, hierarchically hollow silica microtubes (HHSM) were synthesized by a simple sol-gel and calcination method using cetyltrimethyl ammonium bromide (CTAB) and bio-template poplar catkin (PC) as co-templates and the PC/SiO2 weight ratio R was varied from 0, 0.1, 0.3 and 1. The prepared samples were further modified with tetraethylenepentamine (TEPA) and characterized by scanning electron microscope (SEM), transmission electron microscopy (TEM), Fourier transform infrared (FTIR), X-ray photoelectron spectroscopy (XPS), differential thermal analysis (DTA), thermal gravimetric analysis (TGA), and N2 physisorption techniques. This was followed by formaldehyde adsorption tests at ambient temperature. The results showed that all the prepared HHSM samples contained small mesopores with peak pore size at ca. 2.5 nm and large several tens of nanometer-sized pores on the tube wall. The R exhibited an obvious influence on specific surface areas and the sample prepared at R = 0.3 exhibited highest specific surface area (896 m2/g). All the TEPA-modified samples exhibited enhanced formaldehyde adsorption performance. The maximum HCHO adsorption capacity (20.65 mg/g adsorbent) was achieved on the sample prepared at R = 0.3 and modified by 50 wt.% TEPA. The present study will provide new insight for the utilization of bio-template used for the fabrication of inorganic hollow tubes with high HCHO adsorption performance for indoor air purification.

  15. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION AND POST-FIELD SAMPLE HANDLING OF INDOOR FLOOR DUST SAMPLES (UA-F-7.1)

    EPA Science Inventory

    The purpose of this SOP is to establish a uniform procedure for the collection of indoor floor dust samples in the field. This procedure was followed to ensure consistent data retrieval of dust samples during the Arizona NHEXAS project and the Border study. Keywords: field; vacu...

  16. Observations on persistent organic pollutants in indoor and outdoor air using passive polyurethane foam samplers

    NASA Astrophysics Data System (ADS)

    Bohlin, Pernilla; Jones, Kevin C.; Tovalin, Horacio; Strandberg, Bo

    Air quality data of persistent organic pollutants (POPs) indoors and outdoors are sparse or lacking in several parts of the world, often hampered by the cost and inconvenience of active sampling techniques. Cheap and easy passive air sampling techniques are therefore helpful for reconnaissance surveys. As a part of the Megacity Initiative: Local and Global Research Observations (MILAGRO) project in Mexico City Metropolitan Area in 2006, a range of POPs (polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), and polybrominated diphenyl ethers (PBDEs)) were analyzed in polyurethane foam (PUF) disks used as passive samplers in indoor and outdoor air. Results were compared to those from samplers deployed simultaneously in Gothenburg (Sweden) and Lancaster (United Kingdom). Using sampling rates suggested in the literature, the sums of 13 PAHs in the different sites were estimated to be 6.1-180 ng m -3, with phenanthrene as the predominant compound. Indoor PAH levels tended to be higher in Gothenburg and outdoor levels higher in Mexico City. The sum of PCBs ranged 59-2100 ng m -3, and seemed to be highest indoors in Gothenburg and Lancaster. PBDE levels (sum of seven) ranged 0.68-620 ng m -3, with the highest levels found in some indoor locations. OCPs (i.e. DDTs, HCHs, and chlordanes) were widely dispersed both outdoors and indoors at all three studied areas. In Gothenburg all POPs tended to be higher indoors than outdoors, while indoor and outdoor levels in Mexico City were similar. This could be due to the influence of indoor and outdoor sources, air exchange rates, and lifestyle factors. The study demonstrates how passive samplers can provide quick and cheap reconnaissance data simultaneously at many locations which can shed light on sources and other factors influencing POP levels in air, especially for the gaseous fractions.

  17. INDOOR AND OUTDOOR PM10 AND ASSOCIATED METALS AND PESTICIDES IN ARIZONA

    EPA Science Inventory

    The National Human Exposure Assessment Survey study in Arizona (AZ NHEXAS) sampled trace metals in multimedia in and outside of 176 representative homes in Arizona. PM10 was collected using low-flow impactors indoors and out. Primary metals evaluated from monitoring of indoor...

  18. Static SPME sampling of VOCs emitted from indoor building materials: prediction of calibration curves of single compounds for two different emission cells.

    PubMed

    Mocho, Pierre; Desauziers, Valérie

    2011-05-01

    Solid-phase microextraction (SPME) is a powerful technique, easy to implement for on-site static sampling of indoor VOCs emitted by building materials. However, a major constraint lies in the establishment of calibration curves which requires complex generation of standard atmospheres. Thus, the purpose of this paper is to propose a model to predict adsorption kinetics (i.e., calibration curves) of four model VOCs. The model is based on Fick's laws for the gas phase and on the equilibrium or the solid diffusion model for the adsorptive phase. Two samplers (the FLEC® and a home-made cylindrical emission cell), coupled to SPME for static sampling of material emissions, were studied. A good agreement between modeling and experimental data is observed and results show the influence of sampling rate on mass transfer mode in function of sample volume. The equilibrium model is adapted to quite large volume sampler (cylindrical cell) while the solid diffusion model is dedicated to small volume sampler (FLEC®). The limiting steps of mass transfer are the diffusion in gas phase for the cylindrical cell and the pore surface diffusion for the FLEC®. In the future, this modeling approach could be a useful tool for time-saving development of SPME to study building material emission in static mode sampling.

  19. External Exposure to Short- and Medium-Chain Chlorinated Paraffins for the General Population in Beijing, China.

    PubMed

    Gao, Wei; Cao, Dandan; Wang, Yingjun; Wu, Jing; Wang, Ying; Wang, Yawei; Jiang, Guibin

    2018-01-02

    Chlorinated paraffins (CPs) are a class of compounds that are currently produced and used in large amounts in commercial products worldwide. In this study, food, indoor air, indoor dust, and drinking water samples were collected to evaluate the external exposure levels of CPs and possible pathway for the general population in Beijing, China. Short chain CPs (SCCPs) and medium chain CPs (MCCPs) in 199 samples were analyzed using a gas chromatography tandem time-of-flight high-resolution mass spectrometry (GC-TOF-HR-MS) method. High levels of CPs were observed in the indoor environment from residential houses, offices, and student dormitories. The geometric mean concentrations (GM) of ∑SCCPs and ∑MCCPs in indoor dust were 92 μg g -1 and 82 μg g -1 , respectively, while in indoor air, the concentrations were 80 ng m -3 and 3.4 ng m -3 , respectively. The GM of ∑SCCPs and ∑MCCPs in the diet were 83 ng g -1 dry weight (dw) and 56 ng g -1 dw, respectively. The most important external exposure routes to CPs to the general populations in Beijing were food intake and indoor dust ingestion. Indoor dust and indoor air posed higher risks for toddlers and infants than for adults.

  20. Analysis of glycols, glycol ethers, and other volatile organic compounds present in household water-based hand pump sprays.

    PubMed

    Kawakami, Tsuyoshi; Isama, Kazuo; Tanaka-Kagawa, Toshiko; Jinnno, Hideto

    2017-11-10

    The aim of this investigation is to clarify the types and concentrations of VOCs present in various commercial household water-based hand pump spray products used in Japan, and to estimate their average concentrations in indoor air when the spray product is used. We selected glycol and glycol ethers as the main target compounds, as these chemicals were detected at high frequencies and concentrations in a national survey of Japanese indoor air pollution. The extraction of these chemicals using graphite carbon cartridges was examined, with good recoveries and reproducibilities being obtained. Eighteen chemicals were analyzed in 54 commercial products and 8 chemicals were detected. More specifically, dipropylene glycol (DPG) was present in 44 samples (1.1 × 10 1 -1.8 × 10 4 μg/mL); propylene glycol (PG) was present in 22 samples (1.5 × 10 1 -2.9 × 10 4 μg/mL); diethylene glycol monoethyl ether (DGMEE) was found in 15 samples (trace amount-1.9 × 10 3 μg/mL); diethylene glycol (DEG) was present in 9 samples (1.0 × 10 1 -2.4 × 10 3 μg/mL); 1,3-butandiol (13BG) was found in 5 samples (trace amount-7.4 × 10 3 μg/mL); 2-ethyl-1-hexanol (2E1H) was detected in 5 samples (3.2 × 10 -1 -4.4 × 10 1 μg/mL); diethylene glycol monobutyl ether (DGMBE) was present in 4 samples (2.1 × 10 1 -7.1 × 10 1 μg/mL); and 3-methoxy-3-methylbutanol (MMB) was found in 2 samples (2.4 × 10 1 -4.7 × 10 2 μg/mL). In addition, the average concentrations of these chemicals in indoor air were estimated using their maximum concentrations observed in the spray product. The estimated average concentrations of the chemicals in indoor air were determined to range between 1.0 × 10 -2 and 1.0 mg/m 3 , with the exception of 2E1H and DGMBE. Furthermore, the estimated average concentrations of PG, 13BG, and DGMEE in indoor air were comparable to or higher than those reported in a national survey of Japanese indoor air pollution. It therefore appeared that household water-based hand pump sprays may contribute to the presence of these chemicals in indoor air. In contrast, estimated average concentrations of 2E1H in indoor air were low, its concentrations observed in a national survey of Japanese indoor air pollution are likely due to the use of plasticizers and paints.

  1. Utilizing Pyrosequencing and Quantitative pCR to Characterize Fungal Populations among House Dust Samples

    EPA Science Inventory

    Molecular techniques are an alternative to culturing and counting methods in quantifying indoor fungal contamination. Pyrosequencing offers the possibility of identifying unexpected indoor fungi. In this study, 50 house dust samples were collected from homes in the Yakima Valley,...

  2. The mutagenicity of indoor air particles in a residential pilot field study: Application and evaluation of new methodologies

    NASA Astrophysics Data System (ADS)

    Lewtas, Joellen; Goto, Sumio; Williams, Katherine; Chuang, Jane C.; Petersen, Bruce A.; Wilson, Nancy K.

    The mutagenicity of indoor air paniculate matter has been measured in a pilot field study of homes in Columbus, Ohio during the 1984 winter. The study was conducted in eight all natural-gas homes and two all electric homes. Paniculate matter and semi-volatile organic compounds were collected indoors using a medium volume sampler. A micro-forward mutation bioassay employing Salmonella typhimurium strain TM 677 was used to quantify the mutagenicity in solvent extracts of microgram quantities of indoor air particles. The mutagenicity was quantified in terms of both mutation frequency per mg of organic matter extracted and per cubic meter of air sampled. The combustion source variables explored in this study included woodburning in fireplaces and cigarette smoking. Homes in which cigarette smoking occurred had the highest concentrations of mutagenicity per cubic meter of air. The average indoor air mutagenicity per cubic meter was highly correlated with the number of cigarettes smoked. When the separate sampling periods in each room were compared, the mutagenicity in the kitchen samples was the most highly correlated with the number of cigarettes smoked.

  3. Dust Mites Population in Indoor Houses of Suspected Allergic Patients of South Assam, India

    PubMed Central

    Sharma, Dhruba; Dutta, B. K.; Singh, A. B.

    2011-01-01

    Background. In the present study, quality and quantity of indoor dust mites was evaluated at the residence of 150 atopic allergic patients from four different districts of South Assam. Methods. Suspected patients with case history of allergic disease were selected for indoor survey. Dust samples (500 mg) were collected from the selected patient's house and were analyzed using standard methods. Results. About 60% of the selected patients were found suffering from respiratory disorders and rest 40% from skin allergy. The dominant mites recorded from indoor dust samples were Dermatophagoides followed by Blomia, Acarus, and Cheyletus while Caloglyphus was recorded in least number. The distribution of mites on the basis of housing pattern indicates that RCC type of buildings supports maximum dust mite's population followed by Assam type (semi-RCC) buildings, and the lowest count was observed in wooden houses. Environmental factors like temperature, rainfall, and relative humidity are found to determine the indoor mite's population. Severity of allergic attack in some of the typical cases was found to be proportional to the allergen load of mites in the dust samples. Conclusions. The economic status, housing pattern, and local environmental factors determine the diversity and abundance of dust mites in indoor environment. PMID:23724231

  4. Support for indoor tanning policies among young adult women who indoor tan.

    PubMed

    Mays, Darren; Murphy, Sarah E; Bubly, Rachel; Atkins, Michael B; Tercyak, Kenneth P

    2016-12-01

    The purpose of this study to examine support for indoor tanning policies and correlates of policy support among young adult women who indoor tan. Non-Hispanic white women ages 18-30 who indoor tanned in the past year (n = 356, M 23.3 age, SD 3.1) recruited in the Washington, DC area from 2013 to 2016 completed measures of indoor tanning behaviors, attitudes, perceptions, beliefs, and policy support. Most women in the sample supported policies to prevent children under the age of 18 from indoor tanning (74.0 %) and stronger warnings about the risks of indoor tanning on tanning devices (77.6 %); only 10.1 % supported a total ban. In multivariable analyses, support for individual indoor tanning policies varied by demographics (e.g., age), frequent indoor tanning behavior, indoor tanning beliefs, and risk perceptions. Non-Hispanic white young adult women who indoor tan, the primary consumers of indoor tanning, and a high-risk population, largely support indoor tanning prevention policies implemented by many state governments and those currently under review for national enactment. Given low levels of support for a total indoor tanning ban, support for other potential policies (e.g., increasing the minimum age to 21) should be investigated to inform future steps to reduce indoor tanning and the associated health risks.

  5. Relationship between vapor intrusion and human exposure to trichloroethylene.

    PubMed

    Archer, Natalie P; Bradford, Carrie M; Villanacci, John F; Crain, Neil E; Corsi, Richard L; Chambers, David M; Burk, Tonia; Blount, Benjamin C

    2015-01-01

    Trichloroethylene (TCE) in groundwater has the potential to volatilize through soil into indoor air where it can be inhaled. The purpose of this study was to determine whether individuals living above TCE-contaminated groundwater are exposed to TCE through vapor intrusion. We examined associations between TCE concentrations in various environmental media and TCE concentrations in residents. For this assessment, indoor air, outdoor air, soil gas, and tap water samples were collected in and around 36 randomly selected homes; blood samples were collected from 63 residents of these homes. Additionally, a completed exposure survey was collected from each participant. Environmental and blood samples were analyzed for TCE. Mixed model multiple linear regression analyses were performed to determine associations between TCE in residents' blood and TCE in indoor air, outdoor air, and soil gas. Blood TCE concentrations were above the limit of quantitation (LOQ; ≥ 0.012 µg L(-1)) in 17.5% of the blood samples. Of the 36 homes, 54.3%, 47.2%, and >84% had detectable concentrations of TCE in indoor air, outdoor air, and soil gas, respectively. Both indoor air and soil gas concentrations were statistically significantly positively associated with participants' blood concentrations (P = 0.0002 and P = 0.04, respectively). Geometric mean blood concentrations of residents from homes with indoor air concentrations of >1.6 µg m(-3) were approximately 50 times higher than geometric mean blood TCE concentrations in participants from homes with no detectable TCE in indoor air (P < .0001; 95% CI 10.4-236.4). This study confirms the occurrence of vapor intrusion and demonstrates the magnitude of exposure from vapor intrusion of TCE in a residential setting.

  6. Relationship between vapor intrusion and human exposure to trichloroethylene

    PubMed Central

    ARCHER, NATALIE P.; BRADFORD, CARRIE M.; VILLANACCI, JOHN F.; CRAIN, NEIL E.; CORSI, RICHARD L.; CHAMBERS, DAVID M.; BURK, TONIA; BLOUNT, BENJAMIN C.

    2015-01-01

    Trichloroethylene (TCE) in groundwater has the potential to volatilize through soil into indoor air where it can be inhaled. The purpose of this study was to determine whether individuals living above TCE-contaminated groundwater are exposed to TCE through vapor intrusion. We examined associations between TCE concentrations in various environmental media and TCE concentrations in residents. For this assessment, indoor air, outdoor air, soil gas, and tap water samples were collected in and around 36 randomly selected homes; blood samples were collected from 63 residents of these homes. Additionally, a completed exposure survey was collected from each participant. Environmental and blood samples were analyzed for TCE. Mixed model multiple linear regression analyses were performed to determine associations between TCE in residents' blood and TCE in indoor air, outdoor air, and soil gas. Blood TCE concentrations were above the limit of quantitation (LOQ; ≥0.012 μg/L) in 17.5% of the blood samples. Of the 36 homes, 54.3%, 47.2%, and >84% had detectable concentrations of TCE in indoor air, outdoor air, and soil gas, respectively. Both indoor air and soil gas concentrations were statistically significantly positively associated with participants' blood concentrations (p=0.0002 and p=0.04, respectively). Geometric mean blood concentrations of residents from homes with indoor air concentrations of >1.6 μg/m3 were approximately 50 times higher than geometric mean blood TCE concentrations in participants from homes with no detectable TCE in indoor air (p<.0001; 95% CI 10.4 – 236.4). This study confirms the occurrence of vapor intrusion and demonstrates the magnitude of exposure from vapor intrusion of TCE in a residential setting. PMID:26259926

  7. A review of polychlorinated biphenyls (PCBs) pollution in indoor air environment.

    PubMed

    Dai, Qizhou; Min, Xia; Weng, Mili

    2016-10-01

    Polychlorinated biphenyls (PCBs) were widely used in industrial production due to the unique physical and chemical properties. As a kind of persistent organic pollutants, the PCBs would lead to environment pollution and cause serious problems for human health. Thus, they have been banned since the 1980s due to the environment pollution in the past years. Indoor air is the most direct and important environment medium to human beings; thus, the PCBs pollution research in indoor air is important for the protection of human health. This paper introduces the industrial application and potential harm of PCBs, summarizes the sampling, extracting, and analytical methods of environment monitoring, and compares the indoor air levels of urban areas with those of industrial areas in different countries according to various reports. This paper can provide a basic summary for PCBs pollution control in the indoor air environment. The review of PCBs pollution in indoor air in China is still limited. In this paper, we introduce the industrial application and potential harm of PCBs, summarize the sampling, extracting, and analytical methods of environment monitoring, and compare the indoor air levels of urban areas with industrial areas in different countries according to various reports.

  8. US EPA Base Study Standard Operating Procedure for Sampling Volatile Organic Compounds in Indoor Air using Multisorbent Samplers

    EPA Pesticide Factsheets

    The objective of this procedure is to collect representative samples of volatile organic compound (VOC) contaminants present in indoor and outdoor environments using multisorbent samplers, and to subsequently analyze the concentration of VOCs, as selected by EPA.

  9. Characterization of short- and medium-chain chlorinated paraffins in outdoor/indoor PM10/PM2.5/PM1.0 in Beijing, China.

    PubMed

    Huang, Huiting; Gao, Lirong; Xia, Dan; Qiao, Lin; Wang, Runhua; Su, Guijin; Liu, Wenbin; Liu, Guorui; Zheng, Minghui

    2017-06-01

    Persistent organic pollutants (POPs) were listed in the Stockholm Convention, because of their adverse health effects, persistence, bioaccumulation and ubiquitous presence in the environment. Short chain chlorinated paraffins (SCCPs), chlorinated derivatives of n-alkanes, have been listed as candidate POPs under Stockholm Convention. Inhalation uptake was an important exposure pathway for non-occupational adult human and the pollution of particle matter has caused great concern. There are some studies focused on POPs such as polychlorinated biphenyls, polychlorinated dibenzo-p-dioxins and dibenzofurans and polybrominated diphenyl ethers in different size particles. However, there were no studies that discussed CP concentrations in particulate matter (PM) with different sizes. In this study, a total of 30 PM samples were collected both outdoors and indoors at a sampling site in Beijing. These samples were used to investigate the concentrations and distributions of SCCPs and medium chain chlorinated paraffins (MCCPs) in PM fractions of different sizes, and to evaluate inhalation exposure risks. The results showed that the average SCCPs and MCCPs in the outdoor PM 10 were 23.9 and 3.6 ng m -3 , while the mean values in indoor were 61.1 and 6.9 ng m -3 , respectively. The levels of SCCPs and MCCPs in indoor and outdoor were relatively high. SCCP and MCCP concentrations in the indoor PM 10 /PM 2.5 /PM 1.0 samples were higher than the corresponding values in the outdoor, because of the using of some products containing CPs in the indoors, like paints and coatings, leather and rubber products. In both outdoor and indoor air, CPs are mainly associated with particles ≤2.5 μm in diameter. The main homolog groups for both SCCPs and MCCPs were C 10-11 Cl 7-8 . It is assumed that SCCPs in the outdoor and indoor PM samples may mainly derive from the production and use of CP-42 and CP-52. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Participant-based monitoring of indoor and outdoor nitrogen dioxide, volatile organic compounds, and polycyclic aromatic hydrocarbons among MICA-Air households

    NASA Astrophysics Data System (ADS)

    Johnson, Markey M.; Williams, Ron; Fan, Zhihua; Lin, Lin; Hudgens, Edward; Gallagher, Jane; Vette, Alan; Neas, Lucas; Özkaynak, Halûk

    2010-12-01

    The Mechanistic Indicators of Childhood Asthma (MICA) study in Detroit, Michigan introduced a participant-based approach to reduce the resource burden associated with collection of indoor and outdoor residential air sampling data. A subset of participants designated as MICA-Air conducted indoor and outdoor residential sampling of nitrogen dioxide (NO 2), volatile organic compounds (VOCs), and polycyclic aromatic hydrocarbons (PAHs). This participant-based methodology was subsequently adapted for use in the Vanguard phase of the U.S. National Children's Study. The current paper examines residential indoor and outdoor concentrations of these pollutant species among health study participants in Detroit, Michigan. Pollutants measured under MICA-Air agreed well with other studies and continuous monitoring data collected in Detroit. For example, NO 2 and BTEX concentrations reported for other Detroit area monitoring were generally within 10-15% of indoor and outdoor concentrations measured in MICA-Air households. Outdoor NO 2 concentrations were typically higher than indoor NO 2 concentration among MICA-Air homes, with a median indoor/outdoor (I/O) ratio of 0.6 in homes that were not impacted by environmental tobacco smoke (ETS) during air sampling. Indoor concentrations generally exceeded outdoor concentrations for VOC and PAH species measured among non-ETS homes in the study. I/O ratios for BTEX species (benzene, toluene, ethylbenzene, and m/p- and o-xylene) ranged from 1.2 for benzene to 3.1 for toluene. Outdoor NO 2 concentrations were approximately 4.5 ppb higher on weekdays versus weekends. As expected, I/O ratios pollutants were generally higher for homes impacted by ETS. These findings suggest that participant-based air sampling can provide a cost-effective alternative to technician-based approaches for assessing indoor and outdoor residential air pollution in community health studies. We also introduced a technique for estimating daily concentrations at each home by weighting 2- and 7-day integrated concentrations using continuous measurements from regulatory monitoring sites. This approach may be applied to estimate short-term daily or hourly pollutant concentrations in future health studies.

  11. Analytical procedure for the determination of very volatile organic compounds (C3-C6) in indoor air.

    PubMed

    Schieweck, Alexandra; Gunschera, Jan; Varol, Deniz; Salthammer, Tunga

    2018-05-01

    The substance group of very volatile organic compounds (VVOCs) is moving into the focus of indoor air analysis, facing ongoing regulations at international and European levels targeting on indoor air quality and human health. However, there exists at present no validated analysis for the identification and quantification of VVOCs in indoor air. Therefore, the present study targeted on the development of an analytical method in order to sample the maximum possible quantity of VVOCs in indoor air on solid sorbents with subsequent analysis by thermal desorption and coupled gas chromatography/mass spectrometry (TDS-GC/MS). For this purpose, it was necessary to investigate the performance of available sorbents and to optimize the parameters of GC/MS analysis. Stainless steel tubes filled with Carbograph 5TD were applied successfully for low-volume sampling (2-4 l) with minimal breakthrough (< 1%). With the developed method, VVOCs between C 3 and C 6 of different volatility and polarity  can be detected even in trace quantities with low limits of quantitation (LOQ; 1-3 μg m -3 ). Limitations occur for low molecular weight compounds ≤C 3 , especially for polar substances, such as carboxylic acids and for some aldehydes and alcohols. Consequently, established methods for the quantification of these compounds in indoor air cannot be fully substituted yet. At least three different analytical techniques are needed to cover the large spectrum of relevant VVOCs in indoor air. In addition, unexpected reaction products might occur and need to be taken into account to avoid misinterpretation of chromatographic signals. Graphical abstract Solid sorbent sampling of VVOCs (C 3 -C 6 ) in indoor air with subsequent TDS-GC/MS analysis.

  12. Phthalate and non-phthalate plasticizers in indoor dust from childcare facilities, salons, and homes across the USA.

    PubMed

    Subedi, Bikram; Sullivan, Kenneth D; Dhungana, Birendra

    2017-11-01

    The quality of indoor environment has received considerable attention owing to the declining outdoor human activities and the associated public health issues. The prolonged exposure of children in childcare facilities or the occupational exposure of adults to indoor environmental triggers can be a culprit of the pathophysiology of several commonly observed idiopathic syndromes. In this study, concentrations of potentially toxic plasticizers (phthalates as well as non-phthalates) were investigated in 28 dust samples collected from three different indoor environments across the USA. The mean concentrations of non-phthalate plasticizers [acetyl tri-n-butyl citrate (ATBC), di-(2-ethylhexyl) adipate (DEHA), and di-isobutyl adipate (DIBA)] were found at 0.51-880 μg/g for the first time in indoor dust samples from childcare facilities, homes, and salons across the USA. The observed concentrations of these replacement non-phthalate plasticizer were as high as di-(2-ethylhexyl) phthalate, the most frequently detected phthalate plasticizer at highest concentration worldwide, in most of indoor dust samples. The estimated daily intakes of total phthalates (n = 7) by children and toddlers through indoor dust in childcare facilities were 1.6 times higher than the non-phthalate plasticizers (n = 3), whereas estimated daily intake of total non-phthalates for all age groups at homes were 1.9 times higher than the phthalate plasticizers. This study reveals, for the first time, a more elevated (∼3 folds) occupational intake of phthalate and non-phthalate plasticizers through the indoor dust at salons (214 and 285 ng/kg-bw/day, respectively) than at homes in the USA. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. SOURCES OF EMISSIONS OF POLYCHLORINATED BIPHENYLS INTO THE AMBIENT ATMOSPHERE AND INDOOR AIR

    EPA Science Inventory

    Polychlorinated biphenyls (PCB) have been identified in air samples from many parts of the world since 1960s. This study was undertaken to identify and compare different sources of PCB in indoor and outdoor air. All sampling was performed in central North Carolina. The suspected ...

  14. US EPA Base Study Standard Operating Procedure for Sampling Volatile Organic Compounds in Indoor Air Using Evacuated Canisters

    EPA Pesticide Factsheets

    The objective of this procedure is to collect a representative sample of air containing volatile organic compound (VOC) contaminants present in an indoor environment using an evacuated canister, and to subsequently analyze the concentration of VOCs, as selected by EPA.

  15. US EPA Base Study Standard Operating Procedure for Sampling and Characterization of Viable and Non-Viable Bioaerosols in Indoor Air

    EPA Pesticide Factsheets

    The objective of the procedure is to collect a representative sample concentration of total airborne fungal spores (viable and non-viable) that may be present in indoor air and in the outdoor air supplied to the space tested.

  16. Indoor and Outdoor Mobile Mapping Systems for Architectural Surveys

    NASA Astrophysics Data System (ADS)

    Campi, M.; di Luggo, A.; Monaco, S.; Siconolfi, M.; Palomba, D.

    2018-05-01

    This paper presents the results of architectural surveys carried out with mobile mapping systems. The data acquired through different instruments for both indoor and outdoor surveying are analyzed and compared. The study sample shows what is required for an acquisition in a dynamic mode indicating the criteria for the creation of a georeferenced network for indoor spaces, as well as the operational processes concerning data capture, processing, and management. The differences between a dynamic and static scan have been evaluated, with a comparison being made with the aerial photogrammetric survey of the same sample.

  17. Depressive symptoms and indoor tanning among U.S. Hispanic adolescents: Results from a nationally representative sample.

    PubMed

    Gonzales, Manuel; Blashill, Aaron J

    2018-01-01

    To examine the association between depressive symptoms and indoor tanning among U.S. Hispanic adolescents. Data were collected from the 2015 Youth Risk Behavior Survey (YRBS). In the current study, only Hispanic adolescents were included, which yielded a total weighted sample of 2,667 (men: N = 1,368; women: N = 1,299). Gender was also explored as a moderator in the association between depressive symptoms (sadness or hopelessness and suicidality) and indoor tanning. Logistic regressions were used, with past 12 month indoor tanning behavior (0 vs. 1 or more sessions) entered as the dependent variable. Across gender, sadness or hopelessness was associated with increased odds of indoor tanning (OR = 1.8, 95% CI [1.2, 3.0], p = .01); however, gender significantly moderated the association between suicidality and indoor tanning. Simple slope analyses revealed that suicidality was significantly associated with increased odds of indoor tanning only among boys (OR = 4.0, 95% CI [2.1, 7.5], p = .001) whereas a nonsignificant association was found among girls (OR = 0.8, 95% CI [0.4, 1.8], p = .65). Results suggest there is a differential relationship between suicidality and indoor tanning as function of gender among U.S. Hispanic adolescents. Skin cancer prevention programs for Hispanic youth may wish to consider the role of gender and negative affect in targeted campaigns. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  18. Simultaneous and multi-point measurement of ammonia emanating from human skin surface for the estimation of whole body dermal emission rate.

    PubMed

    Furukawa, Shota; Sekine, Yoshika; Kimura, Keita; Umezawa, Kazuo; Asai, Satomi; Miyachi, Hayato

    2017-05-15

    Ammonia is one of the members of odor gases and a possible source of odor in indoor environment. However, little has been known on the actual emission rate of ammonia from the human skin surface. Then, this study aimed to estimate the whole-body dermal emission rate of ammonia by simultaneous and multi-point measurement of emission fluxes of ammonia employing a passive flux sampler - ion chromatography system. Firstly, the emission fluxes of ammonia were non-invasively measured for ten volunteers at 13 sampling positions set in 13 anatomical regions classified by Kurazumi et al. The measured emission fluxes were then converted to partial emission rates using the surface body areas estimated by weights and heights of volunteers and partial rates of 13 body regions. Subsequent summation of the partial emission rates provided the whole body dermal emission rate of ammonia. The results ranged from 2.9 to 12mgh -1 with an average of 5.9±3.2mgh -1 per person for the ten healthy young volunteers. The values were much greater than those from human breath, and thus the dermal emission of ammonia was found more significant odor source than the breath exhalation in indoor environment. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Bacterial diversity among four healthcare-associated institutes in Taiwan.

    PubMed

    Chen, Chang-Hua; Lin, Yaw-Ling; Chen, Kuan-Hsueh; Chen, Wen-Pei; Chen, Zhao-Feng; Kuo, Han-Yueh; Hung, Hsueh-Fen; Tang, Chuan Yi; Liou, Ming-Li

    2017-08-15

    Indoor microbial communities have important implications for human health, especially in health-care institutes (HCIs). The factors that determine the diversity and composition of microbiomes in a built environment remain unclear. Herein, we used 16S rRNA amplicon sequencing to investigate the relationships between building attributes and surface bacterial communities among four HCIs located in three buildings. We examined the surface bacterial communities and environmental parameters in the buildings supplied with different ventilation types and compared the results using a Dirichlet multinomial mixture (DMM)-based approach. A total of 203 samples from the four HCIs were analyzed. Four bacterial communities were grouped using the DMM-based approach, which were highly similar to those in the 4 HCIs. The α-diversity and β-diversity in the naturally ventilated building were different from the conditioner-ventilated building. The bacterial source composition varied across each building. Nine genera were found as the core microbiota shared by all the areas, of which Acinetobacter, Enterobacter, Pseudomonas, and Staphylococcus are regarded as healthcare-associated pathogens (HAPs). The observed relationship between environmental parameters such as core microbiota and surface bacterial diversity suggests that we might manage indoor environments by creating new sanitation protocols, adjusting the ventilation design, and further understanding the transmission routes of HAPs.

  20. AN INDOOR PESTICIDE AIR AND SURFACE CONCENTRATION MODEL

    EPA Science Inventory

    A thorough assessment of human exposure to environmental chemicals requires consideration of all processes in the sequence from source to dose. For assessment of exposure to pesticides following their use indoors, data and models are needed to estimate pesticide concentrations...

  1. Calibration of polydimethylsiloxane and XAD-Pocket passive air samplers (PAS) for measuring gas- and particle-phase SVOCs

    NASA Astrophysics Data System (ADS)

    Okeme, Joseph O.; Saini, Amandeep; Yang, Congqiao; Zhu, Jiping; Smedes, Foppe; Klánová, Jana; Diamond, Miriam L.

    2016-10-01

    Polydimethylsiloxane (PDMS) has seen wide use as the stationary phase of gas chromatographic columns, a passive sampler in water, and recently as a personal exposure sampler, while styrene divinyl-benzene copolymer (XAD) has been used extensively as a passive air sampler outdoors and indoors. We have introduced PDMS and XAD-Pocket as new indoor passive air samplers (PASs). The XAD-Pocket was designed to maximize the surface area-to-volume ratio of XAD and to minimize obstruction of air flow by the sampler housing. Methods were developed to expedite the use of these PASs for measuring phthalates, novel brominated flame-retardants (NFRs) and polybrominated diphenyl ethers (PBDEs) indoors. Sampling rates, Rs, (m3 day-1), were measured during a 7-week calibration study. Variability within and between analyte groups was not statistically significant. As a result, generic values of 0.8 ± 0.4 and 0.5 ± 0.3 m3 day-1 dm-2 are recommended for PDMS and XAD-Pocket for a 50-day deployment time, respectively. PDMS has a higher uptake rate and is easier to use than XAD-Pocket.

  2. A pilot study on nicotine residues in houses of electronic cigarette users, tobacco smokers, and non-users of nicotine-containing products.

    PubMed

    Bush, Derek; Goniewicz, Maciej L

    2015-06-01

    Nicotine deposited on the surfaces has been shown to react with airborne chemicals leading to formation of carcinogens and contributing to thirdhand exposure. While prior studies revealed nicotine residues in tobacco smokers' homes, none have examined the nicotine residue in electronic cigarette (e-cigarette) users' homes. We measured nicotine on the surfaces in households of 8 e-cigarette users, 6 cigarette smokers, and 8 non-users of nicotine-containing products in Western New York, USA. Three surface wipe samples were taken from the floor, wall and window. Nicotine was extracted from the wipes and analyzed using gas chromatography. Half of the e-cigarette users' homes had detectable levels of nicotine on surfaces whereas nicotine was found in all of the tobacco cigarette smokers' homes. Trace amounts of nicotine were also detected in half of the homes of non-users of nicotine-containing products. Nicotine levels in e-cigarette users homes was significantly lower than that found in cigarette smokers homes (average concentration 7.7±17.2 vs. 1303±2676 μg/m2; p<0.05). There was no significant difference in the amount of nicotine in homes of e-cigarette users and non-users (p>0.05). Nicotine is a common contaminant found on indoor surfaces. Using e-cigarettes indoors leads to significantly less thirdhand exposure to nicotine compared to smoking tobacco cigarettes. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Framing Indoor Tanning Warning Messages to Reduce Skin Cancer Risks Among Young Women: Implications for Research and Policy.

    PubMed

    Mays, Darren; Tercyak, Kenneth P

    2015-08-01

    We investigated the impact of indoor tanning device warnings that communicate the risks associated with indoor tanning (i.e., loss framed) or the benefits of avoiding indoor tanning (i.e., gain framed). A convenience sample of non-Hispanic White women aged 18 to 30 years who tanned indoors at least once in the past year (n = 682) participated in a within-subjects experiment. Participants completed baseline measures and reported indoor tanning intentions and intentions to quit indoor tanning in response to 5 warning messages in random order. A text-only control warning was based on Food and Drug Administration-required warnings for indoor tanning devices. Experimental warnings included graphic content and were either gain or loss framed. In multivariable analyses, gain-framed warnings did not differ from the control warning on women's intentions to tan indoors, but they prompted stronger intentions to quit than the control message. Loss-framed warnings significantly reduced intentions to tan indoors and increased intentions to quit indoor tanning compared with control and gain-framed warnings. The public health impact of indoor tanning device warnings can be enhanced by incorporating graphic content and leveraging gain- and loss-framed messaging.

  4. An Improved Simulation of the Diurnally Varying Street Canyon Flow

    NASA Astrophysics Data System (ADS)

    Yaghoobian, Neda; Kleissl, Jan; Paw U, Kyaw Tha

    2012-11-01

    The impact of diurnal variation of temperature distribution over building and ground surfaces on the wind flow and scalar transport in street canyons is numerically investigated using the PArallelized LES Model (PALM). The Temperature of Urban Facets Indoor-Outdoor Building Energy Simulator (TUF-IOBES) is used for predicting urban surface heat fluxes as boundary conditions for a modified version of PALM. TUF-IOBES dynamically simulates indoor and outdoor building surface temperatures and heat fluxes in an urban area taking into account weather conditions, indoor heat sources, building and urban material properties, composition of the building envelope (e.g. windows, insulation), and HVAC equipment. Temperature (and heat flux) distribution over urban surfaces of the 3-D raster-type geometry of TUF-IOBES makes it possible to provide realistic, high resolution boundary conditions for the numerical simulation of flow and scalar transport in an urban canopy. Compared to some previous analyses using uniformly distributed thermal forcing associated with urban surfaces, the present analysis shows that resolving non-uniform thermal forcings can provide more detailed and realistic patterns of the local air flow and pollutant dispersion in urban canyons.

  5. Chemical characteristics and source apportionment of indoor and outdoor fine particles observed in an urban environment in Korea

    NASA Astrophysics Data System (ADS)

    Heo, J.; Yi, S. M.

    2016-12-01

    Paired indoor-outdoor fine particulate matter (PM2.5) samples were collected at subway stations, underground shopping centers, and schools in Seoul metropolitan over a 4-year period between 2004 and 2007. Relationships between indoor and outdoor PM2.5 chemical species were determined and source contributions to indoor and outdoor PM2.5 mass were estimated using a positive matrix factorization (PMF) model. The PM2.5 samples were analyzed for major chemical components including organic carbon and elemental carbon, ions, and metals, and the results were used in the PMF model. The levels of the PM2.5 mass and its chemical components observed at the indoor sites were higher than those at the outdoor sites. Indoor levels of ions (i.e. sulfate, nitrate, ammonium), elemental carbon, and several metals (i.e. Fe, Zn, and Cu) were found to be significantly affected by outdoor sources. Very high indoor-to-outdoor mass ratio of these chemical components, in particular, were observed, representing the significant impacts of outdoor sources on indoor levels of them. Seven sources (secondary sulfate, secondary nitrate, mobile, biomass burning, roadway emissions, dust, and sea salt) were resolved by the PMF model at both of the indoor and outdoor sites. The secondary inorganic aerosol (i.e. secondary sulfate and nitrate) and the mobile sources were major contributors to the indoor and outdoor PM2.5, accounting for 47% and 27% of the outdoor PM2.5 and 40% and 25% of the indoor PM2.5, respectively. Furthermore, the contributions of the secondary inorganic aerosol and the mobile sources to the indoor PM2.5 were very comparable to its corresponding contributions to the outdoor PM2.5 levels. The spatial and temporal characteristics of each of sources resolved by the PMF model across the sites were examined using summary statistics, correlation analysis, and coefficient of variation and divergence analysis and the detailed results will be discussed in the presentation.

  6. Microbiological Assessment of Indoor Air of Teaching Hospital Wards: A case of Jimma University Specialized Hospital.

    PubMed

    Fekadu, Samuel; Getachewu, Bahilu

    2015-04-01

    Hospital environment represents a congenial situation where microorganisms and susceptible patients are indoors together. Thus, the objective of this study is to provide fundamental data related to the microbial quality of indoor air of Jimma University Specialized Hospital wards, to estimate the health hazard and to create standards for indoor air quality control. The microbial quality of indoor air of seven wards of Jimma University Specialized Hospital was determined. Passive air sampling technique, using open Petri-dishes containing different culture media, was employed to collect sample twice daily. The concentrations of bacteria and fungi aerosols in the indoor environment of the wards ranged between 2123 - 9733 CFU/m(3). The statistical analysis showed that the concentrations of bacteria that were measured in all studied wards were significantly different from each other (p-value=0.017), whereas the concentrations of fungi that were measured in all sampled wards were not significantly different from each other (p-value=0.850). Moreover, the concentrations of bacteria that were measured at different sampling time (morning and afternoon) were significantly different (p-value =0.001). All wards that were included in the study were heavily contaminated with bacteria and fungi. Thus, immediate interventions are needed to control those environmental factors which favor the growth and multiplication of microbes, and it is vital to control visitors and students in and out the wards. Moreover, it is advisable that strict measures be put in place to check the increasing microbial load in the hospital environment.

  7. Composition and Source Identification of Chemical Species in Dust from Selected Indoor Environments in Ile-Ife, Nigeria

    NASA Astrophysics Data System (ADS)

    Ogundele, Lasun T.; Olasinde, Roseline T.; Owoade, Oyediran K.; Olise, Felix S.

    2018-05-01

    This study presents the elemental compositions and concentrations of indoor dust and identifies the major sources in some selected indoor environments in Ile-Ife, Nigeria. The dust samples were collected from 16 indoor environments comprising offices, churches, residential and staff quarters using a cyclonic high power vacuum cleaner. The dust samples were analyzed for elemental concentrations using x-ray fluorescences. The data sets were analyzed for the possible sources and their contributions using Principal Component Factor Analysis (PCFA). The result showed that dust samples contained several elements: K, Ca, Ti, Mn, Fe, Ni, Cu, Zn, Ga, As, Rb, Sr, Se, Zr, V, and Sc. The PCFA identified three factors with the percentage variance of 92, 77, 71 and 68%, for the office, church, residential, and staff quarters, respectively, for the combined elemental data of each of the site classes. The identified sources were track-in-soil, road and windblown soil dust, paint debris, household dust from personal care materials, cooking, and cleaning activities. The unintentional track-in-soil due to mobility of the occupants, structural materials, and outdoor air was the major sources contributing to the indoor dust.

  8. State Indoor Tanning Laws and Prevalence of Indoor Tanning Among US High School Students, 2009-2015.

    PubMed

    Qin, Jin; Holman, Dawn M; Jones, Sherry Everett; Berkowitz, Zahava; Guy, Gery P

    2018-07-01

    To examine the association between state indoor tanning laws and indoor tanning behavior using nationally representative samples of US high school students younger than 18 years. We combined data from the 2009, 2011, 2013, and 2015 national Youth Risk Behavior Surveys (n = 41 313) to analyze the association between 2 types of state indoor tanning laws (age restriction and parental permission) and the prevalence of indoor tanning during the 12 months before the survey, adjusting for age, race/ethnicity, and survey year, and stratified by gender. Age restriction laws were associated with a 47% (P < .001) lower indoor tanning prevalence among female high school students. Parental permission laws were not found to be associated with indoor tanning prevalence among either female or male high school students. Age restriction laws could contribute to less indoor tanning, particularly among female high school students. Such reductions may reduce the health and economic burden of skin cancer.

  9. Preschool Teachers' Views on Schools' Indoor and Outdoor Environment Safety

    ERIC Educational Resources Information Center

    Konakli, Tugba; Ülçetin, Esra

    2016-01-01

    The aim of this research is to analyze opinions of teachers who work in preschool education institutions concerning precautions that should be taken for indoor and outdoor security. Study group of this research is determined by criterion sampling from purposeful sampling techniques. The study group of this research is consist of eight preschool…

  10. Method, system and apparatus for monitoring and adjusting the quality of indoor air

    DOEpatents

    Hartenstein, Steven D.; Tremblay, Paul L.; Fryer, Michael O.; Hohorst, Frederick A.

    2004-03-23

    A system, method and apparatus is provided for monitoring and adjusting the quality of indoor air. A sensor array senses an air sample from the indoor air and analyzes the air sample to obtain signatures representative of contaminants in the air sample. When the level or type of contaminant poses a threat or hazard to the occupants, the present invention takes corrective actions which may include introducing additional fresh air. The corrective actions taken are intended to promote overall health of personnel, prevent personnel from being overexposed to hazardous contaminants and minimize the cost of operating the HVAC system. The identification of the contaminants is performed by comparing the signatures provided by the sensor array with a database of known signatures. Upon identification, the system takes corrective actions based on the level of contaminant present. The present invention is capable of learning the identity of previously unknown contaminants, which increases its ability to identify contaminants in the future. Indoor air quality is assured by monitoring the contaminants not only in the indoor air, but also in the outdoor air and the air which is to be recirculated. The present invention is easily adaptable to new and existing HVAC systems. In sum, the present invention is able to monitor and adjust the quality of indoor air in real time by sensing the level and type of contaminants present in indoor air, outdoor and recirculated air, providing an intelligent decision about the quality of the air, and minimizing the cost of operating an HVAC system.

  11. Development of a short path thermal desorption-gas chromatography/mass spectrometry method for the determination of polycyclic aromatic hydrocarbons in indoor air.

    PubMed

    Li, Yingjie; Xian, Qiming; Li, Li

    2017-05-12

    Polycyclic aromatic hydrocarbons (PAHs) are present in petroleum based products and are combustion by-products of organic matters. Determination of levels of PAHs in the indoor environment is important for assessing human exposure to these chemicals. A new short path thermal desorption (SPTD) gas chromatography/mass spectrometry (GC/MS) method for determining levels of PAHs in indoor air was developed. Thermal desorption (TD) tubes packed with glass beads, Carbopack C, and Carbopack B in sequence, were used for sample collection. Indoor air was sampled using a small portable pump over 7 days at 100ml/min. Target PAHs were thermally released and introduced into the GC/MS for analysis through the SPTD unit. During tube desorption, PAHs were cold trapped (-20°C) at the front end of the GC column. Thermal desorption efficiencies were 100% for PAHs with 2 and 3 rings, and 99-97% for PAHs with 4-6 rings. Relative standard deviation (RSD) values among replicate samples spiked at three different levels were around 10-20%. The detection limit of this method was at or below 0.1μg/m 3 except for naphthalene (0.61μg/m 3 ), fluorene (0.28μg/m 3 ) and phenanthrene (0.35μg/m 3 ). This method was applied to measure PAHs in indoor air in nine residential homes. The levels of PAHs in indoor air found in these nine homes are similar to indoor air values reported by others. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Influence of ambient (outdoor) sources on residential indoor and personal PM2.5 concentrations: analyses of RIOPA data.

    PubMed

    Meng, Qing Yu; Turpin, Barbara J; Korn, Leo; Weisel, Clifford P; Morandi, Maria; Colome, Steven; Zhang, Junfeng Jim; Stock, Thomas; Spektor, Dalia; Winer, Arthur; Zhang, Lin; Lee, Jong Hoon; Giovanetti, Robert; Cui, William; Kwon, Jaymin; Alimokhtari, Shahnaz; Shendell, Derek; Jones, Jennifer; Farrar, Corice; Maberti, Silvia

    2005-01-01

    The Relationship of Indoor, Outdoor and Personal Air (RIOPA) study was designed to investigate residential indoor, outdoor and personal exposures to several classes of air pollutants, including volatile organic compounds, carbonyls and fine particles (PM2.5). Samples were collected from summer, 1999 to spring, 2001 in Houston (TX), Los Angeles (CA) and Elizabeth (NJ). Indoor, outdoor and personal PM2.5 samples were collected at 212 nonsmoking residences, 162 of which were sampled twice. Some homes were chosen due to close proximity to ambient sources of one or more target analytes, while others were farther from sources. Median indoor, outdoor and personal PM2.5 mass concentrations for these three sites were 14.4, 15.5 and 31.4 microg/m3, respectively. The contributions of ambient (outdoor) and nonambient sources to indoor and personal concentrations were quantified using a single compartment box model with measured air exchange rate and a random component superposition (RCS) statistical model. The median contribution of ambient sources to indoor PM2.5 concentrations using the mass balance approach was estimated to be 56% for all study homes (63%, 52% and 33% for California, New Jersey and Texas study homes, respectively). Reasonable variations in model assumptions alter median ambient contributions by less than 20%. The mean of the distribution of ambient contributions across study homes agreed well for the mass balance and RCS models, but the distribution was somewhat broader when calculated using the mass balance model with measured air exchange rates.

  13. Estimation of the indoor radon and the annual effective dose from granite samples

    NASA Astrophysics Data System (ADS)

    Sola, P.; Srinuttrakul, W.; Kewsuwan, P.

    2015-05-01

    Inhalation of radon and thoron daughters increases the risk of lung cancer. The main sources of indoor radon are building materials. The aim of this research is to estimate the indoor radon and the annual effective dose from the building materials. Eighteen granite samples bought from the markets in Thailand were measured using an ionization chamber (ATMOS 12 DPX) for the radon concentration in air. Radon exhalation rates were calculated from the radon concentration in chamber. The indoor radon from the granite samples ranged from 10.04 to 55.32 Bq·m-2·h-1 with an average value of 20.30 Bq·m-2·h-1 and the annual effective dose ranged from 0.25 to 1.39 mSv·y-1 with an average value of 0.48 mSv·y-1. The results showed that the annual effective doses of three granite samples were higher than the annual exposure limit for the general public (1 mSv·y-1) recommended by the International Commission on Radiological Protection (ICRP). In addition, the relationship between the colours and radon exhalation rates of granite samples was also explained.

  14. Assessing indoor air quality of school environments: transplanted lichen Pseudovernia furfuracea as a new tool for biomonitoring and bioaccumulation.

    PubMed

    Protano, Carmela; Owczarek, Malgorzata; Antonucci, Arianna; Guidotti, Maurizio; Vitali, Matteo

    2017-07-01

    The aim of this research is to evaluate the ability of transplanted lichen Pseudovernia (P). furfuracea to biomonitor and bioaccumulate in urban indoor environments. The elements As, Cd, Cr, Cu, Hg, Ni and Pb and 12 selected polycyclic aromatic hydrocarbons (PAHs) were used to assess P. furfuracea as a biomonitoring tool for the indoor air quality of school environments. To achieve this purpose, lichen samples were exposed for 2 months in the outdoor and indoor environments of five school settings located in urban and rural areas. The results demonstrated that transplanted lichen P. furfuracea is a suitable biomonitoring tool for metals and PAHs in indoor settings and can discriminate between different levels of air pollution related to urbanisation and indoor conditions, such as those characterised by school environments. A transplanted lichen biomonitoring strategy is cost-effective, "green", educational for attending children and less "invasive" than traditional air sampling methods. The feasibility of indoor monitoring by P. furfuracea is a relevant finding and could be a key tool to improve air quality monitoring programmes in school scenarios and thus focus on health prevention interventions for children, who are one of the most susceptible groups in the population.

  15. Daily indoor-to-outdoor temperature and humidity relationships: a sample across seasons and diverse climatic regions

    PubMed Central

    Nguyen, Jennifer L.; Dockery, Douglas W.

    2015-01-01

    The health consequences of heat and cold are usually evaluated based on associations with outdoor measurements at the nearest weather reporting station. However, people in the developed world spend little time outdoors, especially during extreme temperature events. We examined the association between indoor and outdoor temperature and humidity in a range of climates. We measured indoor temperature, apparent temperature, relative humidity, dew point, and specific humidity (a measure of moisture content in air) for one calendar year (2012) in a convenience sample of eight diverse locations ranging from the equatorial region (10°N) to the Arctic (64°N). We then compared the indoor conditions to outdoor values recorded at the nearest airport weather station. We found that the shape of the indoor-to-outdoor temperature and humidity relationships varied across seasons and locations. Indoor temperatures showed little variation across season and location. There was large variation in indoor relative humidity between seasons and between locations which was independent of outdoor, airport measurements. On the other hand, indoor specific humidity, and to a lesser extent dew point, tracked with outdoor, airport measurements both seasonally and between climates, across a wide range of outdoor temperatures. Our results suggest that, depending on the measure, season, and location, outdoor weather measurements can be reliably used to represent indoor exposures and that, in general, outdoor measures of actual moisture content in air better capture indoor exposure than temperature and relative humidity. Therefore, absolute measures of water vapor should be examined in conjunction with other measures (e.g. temperature, relative humidity) in studies of the effect of weather and climate on human health. PMID:26054827

  16. Risk of HIV infection among indoor and street sex workers and their use of health services in Belgrade, Serbia.

    PubMed

    Ilić, Dragan; Sipetić, Sandra; Bjegović, Vesna

    2010-01-01

    HIV in Serbia is most often transmitted through sexual contact, and therefore numerous prevention activities are geared towards sex workers (SW). To analyse the differences in knowledge, attitudes and risky behaviour between indoor and street SW in Belgrade; to examine the accessibility of health services to this vulnerable group. In this behavioural cross-sectional study, 113 street and 78 indoor SW were included. The sampling method used was snowball samples. Data were gathered through structured questionnaires. Around 15% of respondents used drugs intravenously. Around 60% of SW used a condom during the last sexual intercourse with their private partner, and around 90% with a commercial partner. Indoor SW had lower levels of education more often than outdoor SW, and they used marijuana, sedatives and painkillers on a daily basis. A significantly higher number of indoor SW were informed about HIV, HBV and HCV testing, and that the risk for HIV infection is not lower ifa condom is used exclusively for vaginal sex. Indoor SW reported using health services and testing and counselling for HIV, HBV and HCV more frequently than outdoor SW. Outdoor SW had significantly more sex partners in the previous month than indoor SW. Indoor SW recognized more frequently that providing sex services posed a higher risk for HIV infection. The results of this research study show that even though outdoor SW had higher levels of education than indoor SW, their level of knowledge about HIV transmission was lower and they reported more risky behaviour than indoor SW. Data show that both groups reported not taking care of their health.

  17. Seasonal Variation and Exposure Risks of Perchlorate in Soil, Indoor Dust, and Outdoor Dust in China.

    PubMed

    Li, Yiwen; Liao, Ruoying; Gan, Zhiwei; Qu, Bing; Wang, Rong; Chen, Mengqin; Ding, Sanglan; Su, Shijun

    2018-04-25

    A total of 97 paired soil, outdoor dust, and indoor dust samples were collected in the national scale of China in summer, and the perchlorate levels were compared with those in soil and outdoor dust samples collected in winter in our previous study. The median perchlorate concentrations in the outdoor dust, indoor dust, and soil samples were 8.10, 11.4, and 0.05 mg/kg, respectively, which were significantly lower than those in the winter samples due to the natural factors and human activities. No significant differences in perchlorate concentrations were found between Northern and Southern China in the dust samples, whereas the difference was obtained in the soil samples. In the terms of possible source, the perchlorate levels in the outdoor dust exhibited strong correlation with SO 4 2- (r 2  = 0.458**) and NO 3 - (r 2  = 0.389**), indicating part of perchlorate in outdoor environment was likely from atmospheric oxidative process in summer. The perchlorate, SO 4 2- , and Cl - levels in the indoor dust were significantly related to those in the outdoor dust, suggesting that outdoor contaminants might be an important source for indoor environment. Furthermore, the human exposure to perchlorate was under relatively safe state in China except for special sites or periods with high perchlorate levels. Dust made an unexpected contribution of 41.3% to the total daily perchlorate intake for children, whereas 2.46% for adults in China based on biomonitoring, which deserves more attention.

  18. Temporal variability of indoor air concentrations under natural conditions in a house overlying a dilute chlorinated solvent groundwater plume.

    PubMed

    Holton, Chase; Luo, Hong; Dahlen, Paul; Gorder, Kyle; Dettenmaier, Erik; Johnson, Paul C

    2013-01-01

    Current vapor intrusion (VI) pathway assessment heavily weights concentrations from infrequent (monthly-seasonal) 24 h indoor air samples. This study collected a long-term and high-frequency data set that can be used to assess indoor air sampling strategies for answering key pathway assessment questions like: "Is VI occurring?", and "Will VI impacts exceed thresholds of concern?". Indoor air sampling was conducted for 2.5 years at 2-4 h intervals in a house overlying a dilute chlorinated solvent plume (10-50 μg/L TCE). Indoor air concentrations varied by 3 orders of magnitude (<0.01-10 ppbv TCE) with two recurring behaviors. The VI-active behavior, which was prevalent in fall, winter, and spring involved time-varying impacts intermixed with sporadic periods of inactivity; the VI-dormant behavior, which was prevalent in the summer, involved long periods of inactivity with sporadic VI impacts. These data were used to study outcomes of three simple sparse data sampling plans; the probabilities of false-negative and false-positive decisions were dependent on the ratio of the (action level/true mean of the data), the number of exceedances needed, and the sampling strategy. The analysis also suggested a significant potential for poor characterization of long-term mean concentrations with sparse sampling plans. The results point to a need for additional dense data sets and further investigation into the robustness of possible VI assessment paradigms. As this is the first data set of its kind, it is unknown if the results are representative of other VI-sites.

  19. Field-to-laboratory analysis of clay wall coatings as passive removal materials for ozone in buildings.

    PubMed

    Darling, E; Corsi, R L

    2017-05-01

    Ozone reacts readily with many indoor materials, as well as with compounds in indoor air. These reactions lead to lower indoor than outdoor ozone concentrations when outdoor air is the major contributor to indoor ozone. However, the products of indoor ozone reactions may be irritating or harmful to building occupants. While active technologies exist to reduce indoor ozone concentrations (i.e, in-duct filtration using activated carbon), they can be cost-prohibitive for some and/or infeasible for dwellings that do not have heating, ventilating, and air-conditioning systems. In this study, the potential for passive reduction of indoor ozone by two different clay-based interior surface coatings was explored. These coatings were exposed to occupied residential indoor environments and tested bimonthly in environmental chambers for quantification of ozone reaction probabilities and reaction product emission rates over a 6-month period. Results indicate that clay-based coatings may be effective as passive removal materials, with relatively low by-product emission rates that decay rapidly within 2 months. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Study on Microbial Deposition and Contamination onto Six Surfaces Commonly Used in Chemical and Microbiological Laboratories

    PubMed Central

    Tamburini, Elena; Donegà, Valentina; Marchetti, Maria Gabriella; Pedrini, Paola; Monticelli, Cecilia; Balbo, Andrea

    2015-01-01

    The worktops in both chemical and microbiological laboratories are the surfaces most vulnerable to damage and exposure to contamination by indoor pollutants. The rate at which particles are deposited on indoor surfaces is an important parameter to determine human exposure to airborne biological particles. In contrast to what has been established for inorganic pollutants, no limit has been set by law for microbial contamination in indoor air. To our knowledge, a comparative study on the effect of surfaces on the deposition of microbes has not been carried out. An evaluation of the microbial contamination of worktop materials could be of crucial importance, both for safety reasons and for the reliability of tests and experiments that need to be carried out in non-contaminated environments. The aim of this study was to evaluate the overall microbial contamination (fungi, mesophilic and psychrophilic bacteria, staphylococci) on six widely used worktop materials in laboratories (glass, stainless steel, fine porcelain stoneware, post-forming laminate, high-performing laminate and enamel steel) and to correlate it with the characteristics of the surfaces. After cleaning, the kinetics of microbial re-contamination were also evaluated for all surfaces. PMID:26193296

  1. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR USE OF A PASSIVE SAMPLING DEVICE FOR THE COLLECTION OF AIRBORNE VOCS AT FIXED INDOOR AND OUTDOOR SITES (UA-F-12.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used to sample residential indoor and outdoor atmospheres for the presence of certain volatile organic compounds (VOCs) by means of absorption onto activated charcoal contained within a sampling badge. Activated charcoal diffusi...

  2. Migration of DEHP and DINP into dust from PVC flooring products at different surface temperature.

    PubMed

    Jeon, Seunghwan; Kim, Ki-Tae; Choi, Kyungho

    2016-03-15

    Phthalates are important endocrine disrupting chemicals that have been linked to various adverse human health effects. Phthalates are ubiquitously present in indoor environment and could enter humans. Vinyl or PVC floorings have been recognized as one of important sources of phthalate release to indoor environment including house dust. In the present study, we estimated the migration of di(2-ethylhexyl)phthalate (DEHP) and di-isononyl phthalate (DINP) from the flooring materials into the dust under different heating conditions. For this purpose, a small chamber specifically designed for the present study and a Field and Laboratory Emission Cell (FLEC) were used, and four major types of PVC flooring samples including two UV curing paint coated, an uncoated residential, and a wax-coated commercial type were tested. Migration of DEHP was observed for an uncoated residential type and a wax-coated commercial type flooring. After 14 days of incubation, the levels of DEHP in the dust sample was determined at room temperature on average (standard deviation) at 384 ± 19 and 481 ± 53 μg/g, respectively. In contrast, migration of DINP was not observed. The migration of DEHP was strongly influenced by surface characteristics such as UV curing coating. In the residential flooring coated with UV curing paint, migration of DEHP was not observed at room temperature. But under the heated condition, the release of DEHP was observed in the dust in the FLEC. Migration of DEHP from flooring materials increased when the flooring was heated (50 °C). In Korea, heated flooring system, or 'ondol', is very common mode of heating in residential setting, therefore the contribution of PVC flooring to the total indoor DEHP exposure among general population is expected to be greater especially during winter season when the floor is heated. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Theory-Driven Longitudinal Study Exploring Indoor Tanning Initiation in Teens Using a Person-Centered Approach

    PubMed Central

    Hillhouse, Joel; Turrisi, Rob; Cleveland, Michael J.; Scaglione, Nichole M.; Baker, Katie; Florence, L. Carter

    2015-01-01

    Background Younger indoor tanning initiation leads to greater melanoma risk due to more frequent and persistent behavior. Despite this, there are no published studies exploring the predictors of indoor tanning initiation in teen populations. Purpose This longitudinal study uses latent profile analysis to examine indoor tanning initiation in indoor tanning risk subgroups from a national sample of female adolescents. Methods Latent profile analysis used indoor tanning beliefs and perceptions to identify indoor tanning initiation risk subgroups. The teens in each subgroup were reassessed on indoor tanning initiation after a year. Results Three subgroups were identified: a low-risk, Anti-Tanning subgroup (18.6%) characterized by low scores on positive indoor tanning belief scales and high scores on beliefs about indoor tanning dangers; a moderate-risk Aware Social Tanner subgroup (47.2%) characterized by high scores on positive indoor tanning belief scales but also high scores on beliefs about indoor tanning dangers; and a high-risk Risky Relaxation Tanner subgroup (34.2%) characterized by high scores on positive indoor tanning belief scales and low scores on beliefs about indoor tanning dangers. Teens in the Aware Social Tanner and Risky Relaxation Tanner subgroups were significantly more likely to initiate indoor tanning in the following year. Conclusions These findings highlight the need to identify teens at risk for indoor tanning initiation and develop tailored interventions that will move them to the lowest risk subgroup. Subgroup correlates suggest parent and peer-based interventions may be successful. PMID:26370893

  4. Theory-Driven Longitudinal Study Exploring Indoor Tanning Initiation in Teens Using a Person-Centered Approach.

    PubMed

    Hillhouse, Joel; Turrisi, Rob; Cleveland, Michael J; Scaglione, Nichole M; Baker, Katie; Florence, L Carter

    2016-02-01

    Younger indoor tanning initiation leads to greater melanoma risk due to more frequent and persistent behavior. Despite this, there are no published studies exploring the predictors of indoor tanning initiation in teen populations. This longitudinal study uses latent profile analysis to examine indoor tanning initiation in indoor tanning risk subgroups from a national sample of female adolescents. Latent profile analysis used indoor tanning beliefs and perceptions to identify indoor tanning initiation risk subgroups. The teens in each subgroup were reassessed on indoor tanning initiation after a year. Three subgroups were identified: a low risk, anti-tanning subgroup (18.6 %) characterized by low scores on positive indoor tanning belief scales and high scores on beliefs about indoor tanning dangers; a moderate risk aware social tanner subgroup (47.2 %) characterized by high scores on positive indoor tanning belief scales but also high scores on beliefs about indoor tanning dangers; and a high risk risky relaxation tanner subgroup (34.2 %) characterized by high scores on positive indoor tanning belief scales and low scores on beliefs about indoor tanning dangers. Teens in the aware social tanner and risky relaxation tanner subgroups were significantly more likely to initiate indoor tanning in the following year. These findings highlight the need to identify teens at risk for indoor tanning initiation and develop tailored interventions that will move them to the lowest risk subgroup. Subgroup correlates suggest parent and peer-based interventions may be successful.

  5. Indoor, outdoor, and regional summer and winter concentrations of PM10, PM2.5, SO4(2)-, H+, NH4+, NO3-, NH3, and nitrous acid in homes with and without kerosene space heaters.

    PubMed Central

    Leaderer, B P; Naeher, L; Jankun, T; Balenger, K; Holford, T R; Toth, C; Sullivan, J; Wolfson, J M; Koutrakis, P

    1999-01-01

    Twenty-four-hour samples of PM10 (mass of particles with aerodynamic diameter < or = 10 microm), PM2.5, (mass of particles with aerodynamic diameter < or = 2.5 microm), particle strong acidity (H+), sulfate (SO42-), nitrate (NO3-), ammonia (NH3), nitrous acid (HONO), and sulfur dioxide were collected inside and outside of 281 homes during winter and summer periods. Measurements were also conducted during summer periods at a regional site. A total of 58 homes of nonsmokers were sampled during the summer periods and 223 homes were sampled during the winter periods. Seventy-four of the homes sampled during the winter reported the use of a kerosene heater. All homes sampled in the summer were located in southwest Virginia. All but 20 homes sampled in the winter were also located in southwest Virginia; the remainder of the homes were located in Connecticut. For homes without tobacco combustion, the regional air monitoring site (Vinton, VA) appeared to provide a reasonable estimate of concentrations of PM2.5 and SO42- during summer months outside and inside homes within the region, even when a substantial number of the homes used air conditioning. Average indoor/outdoor ratios for PM2.5 and SO42- during the summer period were 1.03 +/- 0.71 and 0.74 +/- 0.53, respectively. The indoor/outdoor mean ratio for sulfate suggests that on average approximately 75% of the fine aerosol indoors during the summer is associated with outdoor sources. Kerosene heater use during the winter months, in the absence of tobacco combustion, results in substantial increases in indoor concentrations of PM2.5, SO42-, and possibly H+, as compared to homes without kerosene heaters. During their use, we estimated that kerosene heaters added, on average, approximately 40 microg/m3 of PM2.5 and 15 microg/m3 of SO42- to background residential levels of 18 and 2 microg/m3, respectively. Results from using sulfuric acid-doped Teflon (E.I. Du Pont de Nemours & Co., Wilmington, DE) filters in homes with kerosene heaters suggest that acid particle concentrations may be substantially higher than those measured because of acid neutralization by ammonia. During the summer and winter periods indoor concentrations of ammonia are an order of magnitude higher indoors than outdoors and appear to result in lower indoor acid particle concentrations. Nitrous acid levels are higher indoors than outdoors during both winter and summer and are substantially higher in homes with unvented combustion sources. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 PMID:10064553

  6. Indoor air quality in urban and rural kindergartens: short-term studies in Silesia, Poland.

    PubMed

    Błaszczyk, Ewa; Rogula-Kozłowska, Wioletta; Klejnowski, Krzysztof; Kubiesa, Piotr; Fulara, Izabela; Mielżyńska-Švach, Danuta

    2017-01-01

    More than 80% of people living in urban areas who monitor air pollution are exposed to air quality levels that exceed limits defined by the World Health Organization (WHO). Although all regions of the world are affected, populations in low-income cities are the most impacted. According to average annual levels of fine particulate matter (PM2.5, ambient particles with aerodynamic diameter of 2.5 μm or less) presented in the urban air quality database issued by WHO in 2016, as many as 33 Polish cities are among the 50 most polluted cities in the European Union (EU), with Silesian cities topping the list. The aim of this study was to characterize the indoor air quality in Silesian kindergartens based on the concentrations of gaseous compounds (SO 2 , NO 2 ), PM2.5, and the sum of 15 PM2.5-bound polycyclic aromatic hydrocarbons (PAHs), including PM2.5-bound benzo(a)pyrene (BaP), as well as the mutagenic activity of PM2.5 organic extracts in Salmonella assay (strains: TA98, YG1024). The assessment of the indoor air quality was performed taking into consideration the pollution of the atmospheric air (outdoor). I/O ratios (indoor/outdoor concentration) for each investigated parameter were also calculated. Twenty-four-hour samples of PM2.5, SO 2 , and NO 2 were collected during spring in two sites in southern Poland (Silesia), representing urban and rural areas. Indoor samples were taken in naturally ventilated kindergartens. At the same time, in the vicinity of the kindergarten buildings, the collection of outdoor samples of PM2.5, SO 2 , and NO 2 was carried out. The content of BaP and the sum of 15 studied PAHs was determined in each 24-h sample of PM2.5 (indoor and outdoor). In the urban site, statistically lower concentrations of SO 2 and NO 2 were detected indoors compared to outdoors, whereas in the rural site, such a relationship was observed only for NO 2 . No statistically significant differences in the concentrations of PM2.5, PM2.5-bound BaP, and Σ15 PAHs in kindergartens (indoor) versus atmospheric (outdoor) air in the two studied areas were identified. Mutagenic effect of indoor PM2.5 samples was twice as low as in outdoor samples. The I/O ratios indicated that all studied air pollutants in the urban kindergarten originated from the ambient air. In the rural site concentrations of SO 2 , PM2.5 and BaP in the kindergarten were influenced by internal sources (gas and coal stoves).

  7. Fungal contamination assessment in Portuguese elderly care centers.

    PubMed

    Viegas, C; Almeida-Silva, M; Gomes, A Quintal; Wolterbeek, H T; Almeida, S M

    2014-01-01

    Individuals spend 80-90% of their day indoors and elderly subjects are likely to spend even a greater amount of time indoors. Thus, indoor air pollutants such as bioaerosols may exert a significant impact on this age group. The aim of this study was to characterize fungal contamination within Portuguese elderly care centers. Fungi were measured using conventional as well as molecular methods in bedrooms, living rooms, canteens, storage areas, and outdoors. Bioaerosols were evaluated before and after the microenvironments' occupancy in order to understand the role played by occupancy in fungal contamination. Fungal load results varied from 32 colony-forming units CFU m(-3) in bedrooms to 228 CFU m(-3) in storage areas. Penicillium sp. was the most frequently isolated (38.1%), followed by Aspergillus sp. (16.3%) and Chrysonilia sp. (4.2%). With respect to Aspergillus genus, three different fungal species in indoor air were detected, with A. candidus (62.5%) the most prevalent. On surfaces, 40 different fungal species were isolated and the most frequent was Penicillium sp. (22.2%), followed by Aspergillus sp. (17.3%). Real-time polymerase chain reaction did not detect the presence of A. fumigatus complex. Species from Penicillium and Aspergillus genera were the most abundant in air and surfaces. The species A. fumigatus was present in 12.5% of all indoor microenvironments assessed. The living room was the indoor microenvironment with lowest fungal concentration and the storage area was highest.

  8. Movement and deposition of two organophosphorus pesticides within a residence after interior and exterior applications.

    PubMed

    Lewis, R G; Fortune, C R; Blanchard, F T; Camann, D E

    2001-03-01

    Post-application temporal and spatial distributions of two organophosphorus pesticides, diazinon (O,O-diethyl O-[6-methyl-2-(1-methylethyl)-4-pyrimidinyl] phosphorothioate, CAS No. 333-41-5) and chlorpyrifos [O,O-diethyl-O-(2-isopropyl-6-methyl-4-pyrimidinyl) phosphorothioate, CAS No. 2921-88-2], were monitored after homeowner applications for indoor and outdoor insect control. Samples of indoor air, vacuumable carpet dust, carpet dislodgeable residues, deposits on bare floors, table tops and dinnerware, surrogate food, and residues on children's hands and toys were taken before and up to 12 days after treatments in the family room, kitchen, and child's bedroom. Results from the study demonstrate the nature and magnitude of translocation of pesticides from the areas of application to surfaces accessible for human contact and permit comparisons of potential exposures via respiration and dermal contact/oral ingestion. Potential indoor inhalation exposures were estimated to be as high as 0.5 microg/kg/day for diazinon applied indoors and 0.05 microg/kg/day for chlorpyrifos applied to the outside perimeter of the house. While ingestion of carpet dust at the rate of 100 microg/day would have added a maximum of only approximately 0.01 microg/kg/day to the daily dose, residues found on the children's hands suggest that repeated mouthing could have contributed as much as 1-1.5 microg/kg/day. These estimates are below the U.S. Environmental Protection Agency (EPA) reference dose for chlorpyrifos, but exceed those for diazinon.

  9. Relationships between socioeconomic and lifestyle factors and indoor air quality in French dwellings.

    PubMed

    Brown, Terry; Dassonville, Claire; Derbez, Mickael; Ramalho, Olivier; Kirchner, Severine; Crump, Derrick; Mandin, Corinne

    2015-07-01

    To date, few studies have analyzed the relationships between socioeconomic status (SES) and indoor air quality (IAQ). The aim of this study was to examine the relationships between socioeconomic and other factors and indoor air pollutant levels in French homes. The indoor air concentrations of thirty chemical, biological and physical parameters were measured over one week in a sample of 567 dwellings representative of the French housing stock between September 2003 and December 2005. Information on SES (household structure, educational attainment, income, and occupation), building characteristics, and occupants' habits and activities (smoking, cooking, cleaning, etc.) were collected through administered questionnaires. Separate stepwise linear regression models were fitted to log-transformed concentrations on SES and other factors. Logistic regression was performed on fungal contamination data. Households with lower income were more likely to have higher indoor concentrations of formaldehyde, but lower perchloroethylene indoor concentrations. Formaldehyde indoor concentrations were also associated with newly built buildings. Smoking was associated with increasing acetaldehyde and PM2.5 levels and the risk of a positive fungal contamination index. BTEX levels were also associated with occupant density and having an attached garage. The major predictors for fungal contamination were dampness and absolute humidity. These results, obtained from a large sample of dwellings, show for the first time in France the relationships between SES factors and indoor air pollutants, and believe they should be considered alongside occupant activities and building characteristics when study IAQ in homes. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  10. COMPARISON OF MOLD CONCENTRATIONS IN INDOOR AND OUTDOOR AIR SAMPLED SIMULTANEOUSLY AND THEN QUANTIFIED BY MSQPCR

    EPA Science Inventory

    Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of the 36 mold species in indoor and outdoor air samples that were taken simultaneously for 48 hours in and around 17 homes in Cincinnati, Ohio. The total spore concentrations of 353 per m3...

  11. CONCENTRATIONS AND SOLUBILITY OF METALS FROM INDOOR AND PERSONAL EXPOSURE PM2.5 SAMPLES

    EPA Science Inventory

    An assessment of trace metal quantification capabilities for indoor (123 ± 53 μg; mean ± standard deviation of particle mass) and personal exposure (32 ± 12 μg) PM2.5 samples from Baltimore, MD was undertaken as part of an EPA study investigating health effects assoc...

  12. Investigation of the Best Approach for Assessing Human Exposure to Poly- and Perfluoroalkyl Substances through Indoor Air.

    PubMed

    Padilla-Sánchez, Juan A; Papadopoulou, Eleni; Poothong, Somrutai; Haug, Line S

    2017-11-07

    Per- and polyfluoroalkyl substances (PFASs), including fluorotelomer alcohols (FTOHs), perfluoroalkyl sulfonamidoethanols (FOSEs), and perfluoroalkyl sulfonamides (FOSAs), were assessed in 61 residential indoor air and 15 personal air samples collected in Oslo area, Norway. FTOHs were detected in all samples, and the median concentrations in residential indoor air were 2970, 10400, and 3120 pg m -3 for 6:2, 8:2, and 10:2 FTOH, respectively. This is similar to or higher than previously reported in studies from the same geographical area and worldwide. FOSEs and FOSAs were detected in 49-70% and 7-13% of the residential indoor air samples, respectively. The median FTOH concentrations observed in personal air were 1970, 7170, and 1590 pg m -3 for 6:2, 8:2, and 10:2 FTOH, respectively, which is 30 to 50% lower than the median concentrations in residential indoor air. No FOSEs or FOSAs were detected above the method detection limit (MDL) in the personal air samples. Intakes of perfluorohexanoate (PFHxA), perfluoroheptanoate (PFHpA), perfluorooctanoate (PFOA), perfluorononanoate (PFNA), perfluorodecanoate (PFDA), perfluoroundecanoate (PFUnDA), and perfluorooctyl sulfonate (PFOS) through inhalation and biotransformation of PFAS precursors in air were estimated. Median intakes of 1.7, 0.17, 5.7, 0.57, 1.8, 0.18, and 2.3 pg kg bw -1 day -1 were obtained in residential indoor air, while 1.0, 0.10, 3.3, 0.33, 0.88, and 0.09 pg kg bw -1 day -1 were found in personal air for PFHxA, PFHpA, PFOA, PFNA, PFDA, PFUnDA, and PFOS, respectively. The median PFOA intakes from residential indoor air (5.7 pg kg bw -1 day -1 ) and personal air (3.3 pg kg bw -1 day -1 ) were both around 5 orders of magnitude lower than the tolerable daily intake (TDI) reported by the European Food Safety Authority (EFSA).

  13. Comparison of background levels of culturable fungal spore concentrations in indoor and outdoor air in southeastern Austria

    NASA Astrophysics Data System (ADS)

    Haas, D.; Habib, J.; Luxner, J.; Galler, H.; Zarfel, G.; Schlacher, R.; Friedl, H.; Reinthaler, F. F.

    2014-12-01

    Background concentrations of airborne fungi are indispensable criteria for an assessment of fungal concentrations indoors and in the ambient air. The goal of this study was to define the natural background values of culturable fungal spore concentrations as reference values for the assessment of moldy buildings. The concentrations of culturable fungi were determined outdoors as well as indoors in 185 dwellings without visible mold, obvious moisture problems or musty odor. Samples were collected using the MAS-100® microbiological air sampler. The study shows a characteristic seasonal influence on the background levels of Cladosporium, Penicillium and Aspergillus. Cladosporium sp. had a strong outdoor presence, whereas Aspergillus sp. and Penicillium sp. were typical indoor fungi. For the region of Styria, the median outdoor concentrations are between 100 and 940 cfu/m³ for culturable xerophilic fungi in the course of the year. Indoors, median background levels are between 180 and 420 cfu/m³ for xerophilic fungi. The I/O ratios of the airborne fungal spore concentrations were between 0.2 and 2.0. For the assessment of indoor and outdoor air samples the dominant genera Cladosporium, Penicillium and Aspergillus should receive special consideration.

  14. Variability of indoor fungal microbiome of green and non-green low-income homes in Cincinnati, Ohio.

    PubMed

    Coombs, Kanistha; Taft, Diana; Ward, Doyle V; Green, Brett J; Chew, Ginger L; Shamsaei, Behrouz; Meller, Jaroslaw; Indugula, Reshmi; Reponen, Tiina

    2018-01-01

    "Green" housing is designed to use low-impact materials, increase energy efficiency and improve occupant health. However, little is known about the indoor mycobiome of green homes. The current study is a subset of a multicenter study that aims to investigate the indoor environment of green homes and the respiratory health of asthmatic children. In the current study, the mycobiome in air, bed dust and floor dust was compared between green (study site) and non-green (control site), low-income homes in Cincinnati, Ohio. The samples were collected at baseline (within four months following renovation), and 12months after the baseline at the study site. Parallel sample collection was conducted in non-green control homes. Air samples were collected by PM2.5 samplers over 5-days. Bed and floor dust samples were vacuumed after the air sampling was completed. The DNA sample extracts were analyzed using ITS amplicon sequencing. Analysis indicated that there was no clear trend in the fungal communities between green and non-green homes. Instead, fungal community differences were greatest between sample types - air, bed, and floor. Microbial communities also changed substantially between sampling intervals in both green and non-green homes for all sample types, potentially indicating that there was very little stability in the mycobiomes. Research gaps remain regarding how indoor mycobiome fluctuates over time. Longer follow-up periods might elucidate the effect of green renovation on microbial load in buildings. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Framing Indoor Tanning Warning Messages to Reduce Skin Cancer Risks Among Young Women: Implications for Research and Policy

    PubMed Central

    Tercyak, Kenneth P.

    2015-01-01

    Objectives. We investigated the impact of indoor tanning device warnings that communicate the risks associated with indoor tanning (i.e., loss framed) or the benefits of avoiding indoor tanning (i.e., gain framed). Methods. A convenience sample of non-Hispanic White women aged 18 to 30 years who tanned indoors at least once in the past year (n = 682) participated in a within-subjects experiment. Participants completed baseline measures and reported indoor tanning intentions and intentions to quit indoor tanning in response to 5 warning messages in random order. A text-only control warning was based on Food and Drug Administration–required warnings for indoor tanning devices. Experimental warnings included graphic content and were either gain or loss framed. Results. In multivariable analyses, gain-framed warnings did not differ from the control warning on women’s intentions to tan indoors, but they prompted stronger intentions to quit than the control message. Loss-framed warnings significantly reduced intentions to tan indoors and increased intentions to quit indoor tanning compared with control and gain-framed warnings. Conclusions. The public health impact of indoor tanning device warnings can be enhanced by incorporating graphic content and leveraging gain- and loss-framed messaging. PMID:26066932

  16. The analysis of PM2.5 and associated elements and their indoor/outdoor pollution status in an urban area.

    PubMed

    Lim, J-M; Jeong, J-H; Lee, J-H; Moon, J-H; Chung, Y-S; Kim, K-H

    2011-04-01

    In this study, elemental composition of PM2.5 and the status of indoor/outdoor pollution were investigated in a commercial building near a roadside area in Daejeon, Korea. A total of 60 parallel PM2.5 samples were collected both on the roof (outdoor) and in an indoor office of a building near a highly congested road during the spring and fall of 2008. The concentrations of 23 elements were analysed from these PM2.5 samples using instrumental neutron activation analysis. PM2.5 levels in indoor environment (47.6 ± 16.5 μg/m(3)) were noticeably higher than the outdoor levels (37.7 ± 17.2 μg/m(3)) with the I/O concentration ratio of 1.37 ± 0.33 [correlation coefficient (r) = 0.89, P < 0.001]. Principal component analysis results coincidently showed the predominance of sources such as soil dust, traffic, oil/coal combustion and road dust for both indoor and outdoor microenvironments. An isolated source in the indoor environment was assigned to environmental tobacco smoke (ETS) with high factor loading of Ce, Cl, I, K, La and Zn. The overall results of our study indicate that the sources of indoor constituents were strongly dependent on outdoor processes except for the ones affected by independent sources such as ETS. An improved understanding of the factors affecting the indoor PM2.5 concentration levels can lead to the development of an efficient management strategy to control health risks from exposure to indoor PM2.5 and related toxic components. A comparison of our comprehensive data sets indicated that most indoor PM2.5 and associated elemental species were strongly enriched by indoor source activities along with infiltration of ambient outdoor air for a naturally ventilated building. © 2010 John Wiley & Sons A/S.

  17. Polycyclic aromatic hydrocarbons in a bakery indoor air: trends, dynamics, and dispersion.

    PubMed

    Ielpo, Pierina; Taurino, Maria Rosaria; Buccolieri, Riccardo; Placentino, Claudia Marcella; Gallone, Francesco; Ancona, Valeria; Di Sabatino, Silvana

    2018-02-27

    Indoor air pollution assessment in work environments remains challenging due to a combination of logistic reasons and availability of costly instrumentation for data acquisition and post-processing. Existing literature focuses on energy production environments, hospitals, and less so on food production spaces. Studies on indoor air quality in bakeries are scarce or even absent. Motivated by this, the present study investigates indoor air quality in a bakery located in Bari province in South Italy, using a combination of approaches including analytical chemistry analyses and computational fluid dynamics to reconstruct the air ventilation in response to air temperature gradients within the working environment. PM 2.5 indoor samplings were collected every 6 h from 7 to 19 April 2013 in the proximity of two bakery ovens powered by gas and wood, respectively. For each sampling day, 4 PM 2.5 samples were collected: from 3:00 to 9:00 h (first), from 9:00 to 13:30 h (second), from 14:00 to 21:00 h (third), and from 21:00 to 3:00 h (fourth). In total, 40 samples were collected. On each sample, several polycyclic aromatic hydrocarbons (PAHs) were determined such as benzo[a]anthracene (228), benzo[b]fluoranthene (252), benzo[k]fluoranthene (252), benzo[a]pyrene (252), benzo[g,h,i]perylene (276), indeno[1,2,3-cd]pyrene (276), and dibenzo[a,h]anthracene (278), the main compounds of 16 priority US Environmental Protection Agency (US-EPA) PAHs in particulate phase. The PAH mean concentrations showed higher values during the first (from 3:00 to 9:00 h) and fourth (from 21:00 to 3:00 h) sampling intervals than the other two with benzo[a]pyrene mean values exceeding the Italian law limit of 1 ng/m 3 . Taking into account benzo[a]pyrene mean concentration for the first interval and the first plus the second one, which are the hours with the largest working activity, we have estimated that the baker and co-workers are exposed to a cancer risk of 4.3 × 10 -7 and 5.8 × 10 -7 , respectively (these values are lower than US-EPA recommended guideline of 10 -6 ). Our study was complemented by numerical analyses using state-of-the-art computational fluid dynamics to reconstruct at high resolution air movement from the various working places, i.e., the bakery and the selling area which were connected via a door. The numerical simulations were possible given that surface temperature using infrared thermography as well as air temperature was continuously recorded throughout the sampling acquisition. The use of this approach allowed us to estimate the transport and diffusion of benzo[a]pyrene from one area to the other thus complementing the point sampling information. Computational fluid dynamic simulation results confirm the presence of benzo[a]pyrene in the laboratory as obtained from the measurements and suggests its presence in the sales' area of the bakery with concentrations similar those found in the laboratory.

  18. FUNDAMENTAL MASS TRANSFER MODEL FOR INDOOR AIR EMISSIONS FROM SURFACE COATINGS

    EPA Science Inventory

    Emissions from freshly applied paints and other coatings can cause elevated indoor concentrations of vapor-phase organics. Methods are needed to determine the emission rates over time for these products. Some success has been achieved using simple first-order decay models to eval...

  19. Study of the effect of electromagnetic fields on indoor and outdoor radon concentrations

    NASA Astrophysics Data System (ADS)

    Haider, Lina M.; Shareef, N. R.; Darwoysh, H. H.; Mansour, H. L.

    2018-05-01

    In the present work, the effect of electromagnetic fields produced by high voltage power lines(132kV) and indoor equipments on the indoor and outdoor average radon concentrations in Al-Kazaliya and Hay Al-Adil regions in Baghdad city were studied using CR-39 track detectors and a gauss-meter.Results of measurements of the present study, have shown that the highest value for the indoor average radon concentration (76.56± 8.44 Bq / m3) was recorded for sample A1(Hay Al-Adel) at a distance of (20 m) from the high voltage power lines, while the lowest value for the indoor average radon concentration (30.46 ± 8.44 Bq / m3) was recorded for sample A3 (Hay Al-Adil) at a distance of (50 m) from the high voltage power lines. The indoor gaussmeter measurements were found to be ranged from (30.2 mG) to (38.5 mG). The higest value for outdoor average radon concentration and the highest gaussmeter measurements were found for sample (1), with values (92.63 ±11.2 Bq / m3) and (87.24 ± 2.85 mG), directly under the high voltage power lines respectively, while the lowest outdoor average radon concentration and the lowest gaussmeter measurements were found in sample (4),with values (34.19 ± 6.33 Bq / m3) and (1.16 ± 0.14 Bq / m3),), at a distance of (120 m) from the high voltage power lines respectively. The results of the present work have shown that there might be an influence of the electromagnetic field on radon concentrations in areas which were close to high voltage power lines and houses which have used many electric equipment for a long period of time.

  20. Indoor air quality and health problems associated with damp floor coverings.

    PubMed

    Tuomainen, Anneli; Seuri, Markku; Sieppi, Anne

    2004-04-01

    To study the relationship between a high incidence of bronchial asthma among employees working in an office building and an indoor air problem related to the degradation of polyvinyl chloride (PVC) floor coverings in the building. The indoor air measurements and results of renovations are also described. Employees' symptoms were surveyed by a questionnaire, and the incidence of asthma was calculated from the medical records for 1997-2000. The quality of indoor air was assessed by microbial sampling and by investigation of the building for possible moisture damage. Indoor air was sampled for volatile organic compounds (VOCs) through Tenax adsorbent tubes. In situ volatile emission measurements from the concrete floor were performed via the field and laboratory emission cell (FLEC) method. In an office with approximately 150 employees, eight new cases of asthma were found in 4 years. In addition, the workers complained of respiratory, conjunctival and nasal symptoms. Emissions indicating the degradation of plastic floor coverings (e.g. 2-ethyl-1-hexanol, 1-butanol) were found in the indoor air and floor material samples. The plastic floor coverings, adhesives and the levelling layers were carefully removed from 12 rooms. The VOCs had diffused into the underlying concrete slabs. The concrete was warmed to remove the diffused VOCs from these areas. After the repairs the concentrations of the VOCs indicating the degradation of PVC, decreased, as did the prevalence of the employees' symptoms and several asthma patients' need for medication. The workers in the office building complained of several respiratory, conjunctival and dermal symptoms. The incidence of adult-onset asthma was approximately nine-times higher than that among Finns employed in similar work. The most probable single cause of the indoor air problem was the degradation of the plastic floor coverings.

  1. Concentrations and health risk assessment of metal(loid)s in indoor dust from two typical cities of China.

    PubMed

    Li, Yiwen; Pi, Lu; Hu, Wenli; Chen, Mengqin; Luo, Yan; Li, Zhi; Su, Shijun; Gan, Zhiwei; Ding, Sanglan

    2016-05-01

    Eleven trace metal(loid)s were determined in the household dust samples from Chengdu and Tianjin, China, and related human exposure and health risk to metal(loid)s via indoor dust intake were evaluated. The trace metal(loid)s were found to be highly concentrated and polluted in the indoor environment of Chengdu and Tianjin, especially for Cu, Zn, Cd, Sb, and Pb, of which the enrichment factors exceeding 5. Metal(loid) levels in the indoor dust samples exhibited no statistical differences between the two cities, with the exception of Sb, which was detected higher in the Chengdu samples. Bioaccessibilities in stomach phase of each element were estimated, Cd, Pb, and Sr exhibited higher bioaccessibility, and Sb showed the lowest bioaccessibility in both Chengdu and Tianjin. Dust ingestion was the main metal(loid) exposure pathway for Chengdu and Tianjin inhabitants, followed by dermal contact, dust inhalation accounted for less than 1 % of the total daily metal(loid) intakes and thus could be negligible. Children suffered more risk when exposure to metal(loid)s via indoor dust intake due to their higher frequency of hand to mouth activities. Risk evaluation indicated that, for most Chengdu and Tianjin inhabitants, there is little non-cancer and carcinogen risk when exposure to indoor dust. However, there is a potential non-cancer and carcinogen risk for children and adults in Chengdu, in the case of highly exposed scenario based on the current study.

  2. Concentrations and variability of organophosphate esters, halogenated flame retardants, and polybrominated diphenyl ethers in indoor and outdoor air in Stockholm, Sweden.

    PubMed

    Wong, Fiona; de Wit, Cynthia A; Newton, Seth R

    2018-05-10

    We investigated the concentrations and temporal variability of organophospate esters (OPEs), halogenated flame retardants (HFRs) and polybrominated diphenyl ethers (PBDEs) in indoor and outdoor urban air in Stockholm, Sweden over one year (2014-2015) period. The median concentrations of the three target chemical groups (OPEs, HFRs, PBDEs) were 1-2 orders of magnitude higher in indoor air than outdoor urban air. OPEs were the most abundant target FRs with median concentrations in indoor (Σ 10 OPE = 340 000 pg/m 3 ) and outdoor urban (Σ 10 OPEs = 3100 pg/m 3 ) air, being 3 orders of magnitude greater than for HFRs in indoor (Σ 15 HFRs = 120 pg/m 3 ) and outdoor urban (Σ 15 HFRs = 1.6 pg/m 3 ) air. In indoor air, PBDE concentrations (Σ 17 PBDEs = 33 pg/m 3 ) were lower than for the HFRs, but in outdoor urban air, concentrations (Σ 17 PBDEs = 1.1 pg/m 3 ) were similar to HFRs. The most abundant OPEs in both the indoor and outdoor urban air were tris(2-butoxyethyl)phosphate (TBOEP), tris(chloroisopropyl)phosphate (TCIPP), tris(2-chloroethyl)phosphate (TCEP), tri-n-butyl-phosphate (TnBP), triphenyl phosphate (TPhP) and tris(1,3-dichloroisopropyl)phosphate (TDCIPP). TCIPP in indoor air was found in the highest concentrations and showed the greatest temporal variability, which ranged from 85 000 to 1 900 000 pg/m 3 during the one-year sampling period. We speculate that activities in the building, e.g. floor cleaning, polishing, construction, introduction of new electronics and changes in ventilation rate could explain its variation. Some OPEs (TnBP, TCEP, TCIPP, TDCIPP and TPhP), HFRs/PBDEs (pentabromotoluene, 2, 3-dibromopropyl 2, 4, 6-tribromophenyl ether, hexabromobenzene, BDE-28, -47, and -99) in outdoor urban air showed seasonality, with increased concentrations during the warm period (p < 0.05, Pearson's r ranged from -0.45 to -0.91). The observed seasonality for OPEs was probably due to changes in primary emission, and those for the HFRs and PBDEs was likely due to re-volatilization from contaminated surfaces. Copyright © 2018. Published by Elsevier Ltd.

  3. A survey of cyclic and linear siloxanes in indoor dust and their implications for human exposures in twelve countries.

    PubMed

    Tran, Tri Manh; Abualnaja, Khalid O; Asimakopoulos, Alexandros G; Covaci, Adrian; Gevao, Bondi; Johnson-Restrepo, Boris; Kumosani, Taha A; Malarvannan, Govindan; Minh, Tu Binh; Moon, Hyo-Bang; Nakata, Haruhiko; Sinha, Ravindra K; Kannan, Kurunthachalam

    2015-05-01

    Siloxanes are used widely in a variety of consumer products, including cosmetics, personal care products, medical and electrical devices, cookware, and building materials. Nevertheless, little is known on the occurrence of siloxanes in indoor dust. In this survey, five cyclic (D3-D7) and 11 linear (L4-L14) siloxanes were determined in 310 indoor dust samples collected from 12 countries. Dust samples collected from Greece contained the highest concentrations of total cyclic siloxanes (TCSi), ranging from 118 to 25,100ng/g (median: 1380), and total linear siloxanes (TLSi), ranging from 129 to 4990ng/g (median: 772). The median total siloxane (TSi) concentrations in dust samples from 12 countries were in the following decreasing order: Greece (2970ng/g), Kuwait (2400), South Korea (1810), Japan (1500), the USA (1220), China (1070), Romania (538), Colombia (230), Vietnam (206), Saudi Arabia (132), India (116), and Pakistan (68.3). TLSi concentrations as high as 42,800ng/g (Kuwait) and TCSi concentrations as high as 25,000ng/g (Greece) were found in indoor dust samples. Among the 16 siloxanes determined, decamethylcyclopentasiloxane (D5) was found at the highest concentration in dust samples from all countries, except for Japan and South Korea, with a predominance of L11; Kuwait, with L10; and Pakistan and Romania, with L12. The composition profiles of 16 siloxanes in dust samples varied by country. TCSi accounted for a major proportion of TSi concentrations in dust collected from Colombia (90%), India (80%) and Saudi Arabia (70%), whereas TLSi predominated in samples collected from Japan (89%), Kuwait (85%), and South Korea (78%). Based on the measured median TSi concentrations in indoor dust, we estimated human exposure doses through indoor dust ingestion for various age groups. The exposure doses ranged from 0.27 to 11.9ng/kg-bw/d for toddlers and 0.06 to 2.48ng/kg-bw/d for adults. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Indoor Tanning within UK Young Adults: An Extended Theory of Planned Behaviour Approach.

    PubMed

    Dodd, Lorna J; Forshaw, Mark J; Williams, Stella

    2013-01-01

    The indoor tanning industry poses a long-term public health risk. Despite the adverse health effects, indoor tanning seems to be gaining considerable popularity. The study examined indoor tanning intentions and behaviour within UK young adults using an extended theory of planned behaviour model, which included variables on "appearance reasons to tan," "perceived susceptibility to damaging appearance," "perceived susceptibility to health consequences," and "tanning knowledge." The model was successful in predicting indoor tanning intentions and behaviour (explained 17% and 71%, resp.). An interesting outcome was the magnitude of the variable "appearance reasons to tan." A current tanned appearance therefore seemed to outweigh any adverse future appearance or health consequences caused by indoor tanning. Appearance-focused interventions to reduce such behaviour may now prove to be efficacious within a UK sample.

  5. Indoor calibration for stereoscopic camera STC: a new method

    NASA Astrophysics Data System (ADS)

    Simioni, E.; Re, C.; Da Deppo, V.; Naletto, G.; Borrelli, D.; Dami, M.; Ficai Veltroni, I.; Cremonese, G.

    2017-11-01

    In the framework of the ESA-JAXA BepiColombo mission to Mercury, the global mapping of the planet will be performed by the on-board Stereo Camera (STC), part of the SIMBIO-SYS suite [1]. In this paper we propose a new technique for the validation of the 3D reconstruction of planetary surface from images acquired with a stereo camera. STC will provide a three-dimensional reconstruction of Mercury surface. The generation of a DTM of the observed features is based on the processing of the acquired images and on the knowledge of the intrinsic and extrinsic parameters of the optical system. The new stereo concept developed for STC needs a pre-flight verification of the actual capabilities to obtain elevation information from stereo couples: for this, a stereo validation setup to get an indoor reproduction of the flight observing condition of the instrument would give a much greater confidence to the developed instrument design. STC is the first stereo satellite camera with two optical channels converging in a unique sensor. Its optical model is based on a brand new concept to minimize mass and volume and to allow push-frame imaging. This model imposed to define a new calibration pipeline to test the reconstruction method in a controlled ambient. An ad-hoc indoor set-up has been realized for validating the instrument designed to operate in deep space, i.e. in-flight STC will have to deal with source/target essentially placed at infinity. This auxiliary indoor setup permits on one side to rescale the stereo reconstruction problem from the operative distance in-flight of 400 km to almost 1 meter in lab; on the other side it allows to replicate different viewing angles for the considered targets. Neglecting for sake of simplicity the Mercury curvature, the STC observing geometry of the same portion of the planet surface at periherm corresponds to a rotation of the spacecraft (SC) around the observed target by twice the 20° separation of each channel with respect to nadir. The indoor simulation of the SC trajectory can therefore be provided by two rotation stages to generate a dual system of the real one with same stereo parameters but different scale. The set of acquired images will be used to get a 3D reconstruction of the target: depth information retrieved from stereo reconstruction and the known features of the target will allow to get an evaluation of the stereo system performance both in terms of horizontal resolution and vertical accuracy. To verify the 3D reconstruction capabilities of STC by means of this stereo validation set-up, the lab target surface should provide a reference, i.e. should be known with an accuracy better than that required on the 3D reconstruction itself. For this reason, the rock samples accurately selected to be used as lab targets have been measured with a suitable accurate 3D laser scanner. The paper will show this method in detail analyzing all the choices adopted to lead back a so complex system to the indoor solution for calibration.

  6. Indoor Calibration for Stereoscopic Camera STC, A New Method

    NASA Astrophysics Data System (ADS)

    Simioni, E.; Re, C.; Da Deppo, V.; Naletto, G.; Borrelli, D.; Dami, M.; Ficai Veltroni, I.; Cremonese, G.

    2014-10-01

    In the framework of the ESA-JAXA BepiColombo mission to Mercury, the global mapping of the planet will be performed by the on-board Stereo Camera (STC), part of the SIMBIO-SYS suite [1]. In this paper we propose a new technique for the validation of the 3D reconstruction of planetary surface from images acquired with a stereo camera. STC will provide a three-dimensional reconstruction of Mercury surface. The generation of a DTM of the observed features is based on the processing of the acquired images and on the knowledge of the intrinsic and extrinsic parameters of the optical system. The new stereo concept developed for STC needs a pre-flight verification of the actual capabilities to obtain elevation information from stereo couples: for this, a stereo validation setup to get an indoor reproduction of the flight observing condition of the instrument would give a much greater confidence to the developed instrument design. STC is the first stereo satellite camera with two optical channels converging in a unique sensor. Its optical model is based on a brand new concept to minimize mass and volume and to allow push-frame imaging. This model imposed to define a new calibration pipeline to test the reconstruction method in a controlled ambient. An ad-hoc indoor set-up has been realized for validating the instrument designed to operate in deep space, i.e. in-flight STC will have to deal with source/target essentially placed at infinity. This auxiliary indoor setup permits on one side to rescale the stereo reconstruction problem from the operative distance in-flight of 400 km to almost 1 meter in lab; on the other side it allows to replicate different viewing angles for the considered targets. Neglecting for sake of simplicity the Mercury curvature, the STC observing geometry of the same portion of the planet surface at periherm corresponds to a rotation of the spacecraft (SC) around the observed target by twice the 20° separation of each channel with respect to nadir. The indoor simulation of the SC trajectory can therefore be provided by two rotation stages to generate a dual system of the real one with same stereo parameters but different scale. The set of acquired images will be used to get a 3D reconstruction of the target: depth information retrieved from stereo reconstruction and the known features of the target will allow to get an evaluation of the stereo system performance both in terms of horizontal resolution and vertical accuracy. To verify the 3D reconstruction capabilities of STC by means of this stereo validation set-up, the lab target surface should provide a reference, i.e. should be known with an accuracy better than that required on the 3D reconstruction itself. For this reason, the rock samples accurately selected to be used as lab targets have been measured with a suitable accurate 3D laser scanner. The paper will show this method in detail analyzing all the choices adopted to lead back a so complex system to the indoor solution for calibration.

  7. Enhanced Detection of Surface-Associated Bacteria in Indoor Environments by Quantitative PCR

    PubMed Central

    Buttner, Mark P.; Cruz-Perez, Patricia; Stetzenbach, Linda D.

    2001-01-01

    Methods for detecting microorganisms on surfaces are needed to locate biocontamination sources and to relate surface and airborne concentrations. Research was conducted in an experimental room to evaluate surface sampling methods and quantitative PCR (QPCR) for enhanced detection of a target biocontaminant present on flooring materials. QPCR and culture analyses were used to quantitate Bacillus subtilis (Bacillus globigii) endospores on vinyl tile, commercial carpet, and new and soiled residential carpet with samples obtained by four surface sampling methods: a swab kit, a sponge swipe, a cotton swab, and a bulk method. The initial data showed that greater overall sensitivity was obtained with the QPCR than with culture analysis; however, the QPCR results for bulk samples from residential carpet were negative. The swab kit and the sponge swipe methods were then tested with two levels of background biological contamination consisting of Penicillium chrysogenum spores. The B. subtilis values obtained by the QPCR method were greater than those obtained by culture analysis. The differences between the QPCR and culture data were significant for the samples obtained with the swab kit for all flooring materials except soiled residential carpet and with the sponge swipe for commercial carpet. The QPCR data showed that there were no significant differences between the swab kit and sponge swipe sampling methods for any of the flooring materials. Inhibition of QPCR due solely to biological contamination of flooring materials was not evident. However, some degree of inhibition was observed with the soiled residential carpet, which may have been caused by the presence of abiotic contaminants, alone or in combination with biological contaminants. The results of this research demonstrate the ability of QPCR to enhance detection and enumeration of biocontaminants on surface materials and provide information concerning the comparability of currently available surface sampling methods. PMID:11375164

  8. Indoor air condensate as a novel matrix for monitoring inhalable organic contaminants.

    PubMed

    Roll, Isaac B; Halden, Rolf U; Pycke, Benny F G

    2015-05-15

    With the population of developed nations spending nearly 90% of their time indoors, indoor air quality (IAQ) is a critical indicator of human health risks from inhalation of airborne contaminants. We present a novel approach for qualitative monitoring of IAQ through the collection and analysis of indoor air condensate discharged from heat exchangers of heating, ventilation, and air conditioning (HVAC) systems. Condensate samples were collected from six suburban homes and one business in Maricopa County, Arizona, concentrated via solid-phase extraction, analyzed for 10 endocrine disrupting chemicals (EDCs) by liquid chromatography-tandem mass spectrometry (LC-MS/MS), and screened for additional organic compounds by gas chromatography-mass spectrometry (GC-MS). All 10 EDCs were detected in at least one of the sampled buildings. More than 100 additional compounds were detected by GC-MS, of which 40 were tentatively identified using spectral database searches. Twelve compounds listed as designated chemicals for biomonitoring by the California Environmental Contaminant Biomonitoring Program were detected. Microfiltration of condensate samples prior to extraction had no discernable effect on contaminant concentration, suggesting that contaminants were freely dissolved or associated with inhalable, submicron particles. This study is the first to document the utility of HVAC condensate for the qualitative assessment of indoor air for pollutants. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. PM2.5-bound PAHs in three indoor and one outdoor air in Beijing: Concentration, source and health risk assessment.

    PubMed

    Chen, Ying; Li, Xinghua; Zhu, Tianle; Han, Yingjie; Lv, Dong

    2017-05-15

    Three indoor (residential home, dormitory, and office) and one outdoor concentrations of PM 2.5 -bound Polycyclic aromatic hydrocarbons (PAHs) were analyzed in Beijing across four seasons. The highest and lowest concentration of total PAHs for outdoor appeared in winter and in summer with averages of 200.1 and 9.1ng/m 3 respectively. The seasonal variations of total PAHs in three indoor sites were the same as outdoor. The correlation analysis between the indoor and outdoor samples showed that the annual mean I/O ratios of total PAHs in the three sites were lower than 1. Source apportionment showed vehicle exhaust, coal combustion, and biomass burning were the major contributors of indoor and outdoor PM 2.5 -bound PAHs. Indoor source, such as camphor pollution, was identified in the dormitory, while camphor pollution and cooking sources were identified in the residential home. The annual averages of Benzo[a]pyrene equivalent concentration (BaP eq ) were 7.6, 7.8, 7.7 and 12.7ng/m 3 for the dormitory, office, residential home and outdoor samples respectively, far higher than the annual limit of 1ng/m 3 regulated by European Commission. Life lung cancer risk (LLCR) in four sites across four seasons were over the acceptable cancer risk level, showing the cancer risk were at a high level in both indoor and outdoor sites in Beijing, and its level in indoor sites was much lower than in the outdoor site. The health risk assessment indicated the level of PAHs cancer risk on human for three indoor sites were similar. The results call for the development of more stringent control measures to reduce PAHs emissions. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Relationships among indoor, outdoor, and personal airborne Japanese cedar pollen counts.

    PubMed

    Yamamoto, Naomichi; Matsuki, Yuuki; Yokoyama, Hiromichi; Matsuki, Hideaki

    2015-01-01

    Japanese cedar pollinosis (JCP) is an important illness caused by the inhalation of airborne allergenic cedar pollens, which are dispersed in the early spring throughout the Japanese islands. However, associations between pollen exposures and the prevalence or severity of allergic symptoms are largely unknown, due to a lack of understanding regarding personal pollen exposures in relation to indoor and outdoor concentrations. This study aims to examine the relationships among indoor, outdoor, and personal airborne Japanese cedar pollen counts. We conducted a 4-year monitoring campaign to quantify indoor, outdoor, and personal airborne cedar pollen counts, where the personal passive settling sampler that has been previously validated against a volumetric sampler was used to count airborne pollen grains. A total of 256 sets of indoor, outdoor, and personal samples (768 samples) were collected from 9 subjects. Medians of the seasonally-integrated indoor-to-outdoor, personal-to-outdoor, and personal-to-indoor ratios of airborne pollen counts measured for 9 subjects were 0.08, 0.10, and 1.19, respectively. A greater correlation was observed between the personal and indoor counts (r = 0.89) than between the personal and outdoor counts (r = 0.71), suggesting a potential inaccuracy in the use of outdoor counts as a basis for estimating personal exposures. The personal pollen counts differed substantially among the human subjects (49% geometric coefficient of variation), in part due to the variability in the indoor counts that have been found as major determinants of the personal pollen counts. The findings of this study highlight the need for pollen monitoring in proximity to human subjects to better understand the relationships between pollen exposures and the prevalence or severity of pollen allergy.

  11. Relationships among Indoor, Outdoor, and Personal Airborne Japanese Cedar Pollen Counts

    PubMed Central

    Yamamoto, Naomichi; Matsuki, Yuuki; Yokoyama, Hiromichi; Matsuki, Hideaki

    2015-01-01

    Japanese cedar pollinosis (JCP) is an important illness caused by the inhalation of airborne allergenic cedar pollens, which are dispersed in the early spring throughout the Japanese islands. However, associations between pollen exposures and the prevalence or severity of allergic symptoms are largely unknown, due to a lack of understanding regarding personal pollen exposures in relation to indoor and outdoor concentrations. This study aims to examine the relationships among indoor, outdoor, and personal airborne Japanese cedar pollen counts. We conducted a 4-year monitoring campaign to quantify indoor, outdoor, and personal airborne cedar pollen counts, where the personal passive settling sampler that has been previously validated against a volumetric sampler was used to count airborne pollen grains. A total of 256 sets of indoor, outdoor, and personal samples (768 samples) were collected from 9 subjects. Medians of the seasonally-integrated indoor-to-outdoor, personal-to-outdoor, and personal-to-indoor ratios of airborne pollen counts measured for 9 subjects were 0.08, 0.10, and 1.19, respectively. A greater correlation was observed between the personal and indoor counts (r = 0.89) than between the personal and outdoor counts (r = 0.71), suggesting a potential inaccuracy in the use of outdoor counts as a basis for estimating personal exposures. The personal pollen counts differed substantially among the human subjects (49% geometric coefficient of variation), in part due to the variability in the indoor counts that have been found as major determinants of the personal pollen counts. The findings of this study highlight the need for pollen monitoring in proximity to human subjects to better understand the relationships between pollen exposures and the prevalence or severity of pollen allergy. PMID:26110813

  12. Indoor Heating Drives Water Bacterial Growth and Community Metabolic Profile Changes in Building Tap Pipes during the Winter Season

    PubMed Central

    Zhang, Hai-Han; Chen, Sheng-Nan; Huang, Ting-Lin; Shang, Pan-Lu; Yang, Xiao; Ma, Wei-Xing

    2015-01-01

    The growth of the bacterial community harbored in indoor drinking water taps is regulated by external environmental factors, such as indoor temperature. However, the effect of indoor heating on bacterial regrowth associated with indoor drinking water taps is poorly understood. In the present work, flow cytometry and community-level sole-carbon-source utilization techniques were combined to explore the effects of indoor heating on water bacterial cell concentrations and community carbon metabolic profiles in building tap pipes during the winter season. The results showed that the temperature of water stagnated overnight (“before”) in the indoor water pipes was 15–17 °C, and the water temperature decreased to 4–6 °C after flushing for 10 min (“flushed”). The highest bacterial cell number was observed in water stagnated overnight, and was 5–11 times higher than that of flushed water. Meanwhile, a significantly higher bacterial community metabolic activity (AWCD590nm) was also found in overnight stagnation water samples. The significant “flushed” and “taps” values indicated that the AWCD590nm, and bacterial cell number varied among the taps within the flushed group (p < 0.01). Heatmap fingerprints and principle component analyses (PCA) revealed a significant discrimination bacterial community functional metabolic profiles in the water stagnated overnight and flushed water. Serine, threonine, glucose-phosphate, ketobutyric acid, phenylethylamine, glycerol, putrescine were significantly used by “before” water samples. The results suggested that water stagnated at higher temperature should be treated before drinking because of bacterial regrowth. The data from this work provides useful information on reasonable utilization of drinking water after stagnation in indoor pipes during indoor heating periods. PMID:26516885

  13. VOLATILE ORGANIC COMPOUND EMISSIONS FROM LATEX PAINT - PART 1. CHAMBER EXPERIMENTS AND SOURCE MODEL DEVELOPMENT

    EPA Science Inventory

    Latex paints are widely used in residential and commercial indoor environments. The surface areas covered by the paints in these environments are relatively large. Thus, latex paints have the potential for having a major impact on indoor air quality (IAQ). A study was undertaken ...

  14. DECONTAMINATION ASSESSMENT OF BACILLUS ANTHRACIS, BACILLUS SUBTILIS, AND GEOBACILLUS STEAROTHERMOPHILUS SPORES ON INDOOR SURFACTS USING A HYDROGEN PERIOXIDE GAS GENERATOR

    EPA Science Inventory

    Aims: To evaluate the decontamination of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surface materials using hydrogen peroxide gas. Methods and Results: B. anthracis, B. subtilis, and G. Stearothermophilus spores were dried on seven...

  15. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF FIXED SITE INDOOR AND OUTDOOR FORMALDEHYDE PASSIVE SAMPLES (UA-F-13.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used to sample residential indoor and outdoor atmospheres for the presence of formaldehyde using the PF-1 passive formaldehyde sampler. The PF-1 passive sampler is used as a fixed location monitor to determine time integrated ex...

  16. Transient Method for Determining Indoor Chemical Concentrations Based on SPME: Model Development and Calibration.

    PubMed

    Cao, Jianping; Xiong, Jianyin; Wang, Lixin; Xu, Ying; Zhang, Yinping

    2016-09-06

    Solid-phase microextraction (SPME) is regarded as a nonexhaustive sampling technique with a smaller extraction volume and a shorter extraction time than traditional sampling techniques and is hence widely used. The SPME sampling process is affected by the convection or diffusion effect along the coating surface, but this factor has seldom been studied. This paper derives an analytical model to characterize SPME sampling for semivolatile organic compounds (SVOCs) as well as for volatile organic compounds (VOCs) by considering the surface mass transfer process. Using this model, the chemical concentrations in a sample matrix can be conveniently calculated. In addition, the model can be used to determine the characteristic parameters (partition coefficient and diffusion coefficient) for typical SPME chemical samplings (SPME calibration). Experiments using SPME samplings of two typical SVOCs, dibutyl phthalate (DBP) in sealed chamber and di(2-ethylhexyl) phthalate (DEHP) in ventilated chamber, were performed to measure the two characteristic parameters. The experimental results demonstrated the effectiveness of the model and calibration method. Experimental data from the literature (VOCs sampled by SPME) were used to further validate the model. This study should prove useful for relatively rapid quantification of concentrations of different chemicals in various circumstances with SPME.

  17. Photoenhanced uptakes of NO2 by indoor surfaces: A new HONO source

    NASA Astrophysics Data System (ADS)

    Gligorovski, S.; Bartolomei, V.; Soergel, M.; Gomez Alvarez, E.; Zetzsch, C.; Wortham, H.

    2012-12-01

    Nitrous acid (HONO) is a known household pollutant that can lead to human respiratory tract irritation. HONO acts as the nitrosating agent, e.g. by the formation of the so-called third-hand smoke after wall reactions of HONO with nicotine (1). HONO can be generated indoors directly during combustion processes or indirectly via heterogeneous NO2 reactions with adsorbed water on diverse surfaces (2). Recently a new source was identified as another path of HONO formation in the troposphere (3). Namely, the light-induced heterogeneous reaction of NO2 with adsorbed organics (known as photosensitizers) on various surfaces such as roads, buildings, rocks or plants leads to enhanced HONO production. The detected values of HONO indoors vary in the range between 2 and 25 parts per billion (ppb). However, like outdoors, the processes leading to HONO formation indoors are not completely understood (4). Indoor photolysis radiation sources include exterior sunlight (λ>350 nm) that enters typically through the windows and indoor illumination sources, i.e., rare gas/mercury fluorescent light bulbs and tungsten and tungsten/halogen light bulbs among others. The present work is showing the importance of indoor sources of HONO recently identified or postulated. We have tested a number of common household chemical agents commonly used for cleaning purposes or coatings of domestic surfaces to better identify different indoor HONO sources. We used a heterogeneous flow tube technique to test the HONO production potentials of these household chemical agents under different experimental conditions, namely with and without light and at different relative humidity levels and different NO2 concentrations. We report uptake kinetics measurements of the heterogeneous reaction of gas phase NO2 with lacquer and paint coated on the walls of the reactor. The flow tube was irradiated with four near-ultraviolet (UV) emitting lamps (range of wavelengths 300-420nm). We observed that the heterogeneous conversion of NO2 to HONO on lacquer surfaces and on white wall paints is substantially enhanced in the presence of light and at higher relative humidity (RH = 60%). In runs carried out applying experimental conditions typically found indoors, i.e., NO2 mixing ratios of 25 ppb and 60% RH%, the observed NO2 uptakes on a surface coated with lacquer and paint showed an enhancement of one order of magnitude in the presence of light as compared to the uptake observed in the dark. Our results indicate, contrary to other study that claimed that humidity does not influence the NO2 reactions with adsorbed organics, that actually both postulated HONO sources combined i.e. heterogeneous NO2 reactions with adsorbed organics (photosensitizers) in presence of elevated humidity leads to even more pronounced HONO production. Reference: 1. M., Sleiman, L. A., Gundel, J. F., Pankow, P., Jacob, B. C., Singer, H., Destaillats, P. Natl. Acad. Sci. USA, 107, 6576 (2010). 2. B. J. Finlayson-Pitts, L. M. Wingen, A. L. Sumner, D. Syomin, K. A. Ramazan, Phys. Chem. Chem. Phys. 5, 223 (2003). 3. K., Stemmler, M., Ammann, C., Donders, J., Kleffmann, C., George, Nature 440, 195 (2006). 4. E. Gomez Alvarez, H. Wortham, R. Strekowski, C. Zetzsch, S. Gligorovski, Environ. Sci. Technol., 46, 1955 (2012).

  18. Dynamic behavior of semivolatile organic compounds in indoor air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loy, Michael David Van

    1998-12-09

    Exposures to a wide range of air pollutants are often dominated by those occurring in buildings because of three factors: 1) most people spend a large fraction of their time indoors, 2) many pollutants have strong indoor sources, and 3) the dilution volume in buildings is generally several orders of magnitude smaller than that of an urban airshed. Semivolatile organic compounds (SVOCS) are emitted by numerous indoor sources, including tobacco combustion, cooking, carpets, paints, resins, and glues, so indoor gasphase concentrations of these compounds are likely to be elevated relative to ambient levels. The rates of uptake and release ofmore » reversibly sorbing SVOCS by indoor materials directly affect both peak concentrations and persistence of the pollutants indoors after source elimination. Thus, accurate predictions of SVOC dynamics in indoor air require an understanding of contaminant sorption on surface materials such as carpet and wallboard. The dynamic behaviors of gas-phase nicotine and phenanthrene were investigated in a 20 ms stainless steel chamber containing carpet and painted wallboard. Each compound was studied independently, first in the empty chamber, then with each sorbent individually, and finally with both sorbents in the chamber.« less

  19. Methamphetamine absorption by skin lipids: accumulated mass, partition coefficients, and the influence of fatty acids.

    PubMed

    Parker, K; Morrison, G

    2016-08-01

    Occupants of former methamphetamine laboratories, often residences, may experience increased exposure through the accumulation of the methamphetamine in the organic films that coat skin and indoor surfaces. The objectives of this study were to determine equilibrium partition coefficients of vapor-phase methamphetamine with artificial sebum (AS-1), artificial sebum without fatty acids (AS-2), and real skin surface films, herein called skin oils. Sebum and skin oil-coated filters were exposed to vapor-phase methamphetamine at concentrations ranging from 8 to 159 ppb, and samples were analyzed for exposure time periods from 2 h to 60 days. For a low vapor-phase methamphetamine concentration range of ~8-22 ppb, the equilibrium partition coefficient for AS-1 was 1500 ± 195 μg/g/ppb. For a high concentration range of 98-112 ppb, the partition coefficient was lower, 459 ± 80 μg/g/ppb, suggesting saturation of the available absorption capacity. The low partition coefficient for AS-2 (33 ± 6 μg/g/ppb) suggests that the fatty acids in AS-1 and skin oil are responsible for much high partition coefficients. We predict that the methamphetamine concentration in skin lipids coating indoor surfaces can exceed recommended surface remediation standards even for air concentrations well below 1 ppb. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. A preliminary examination of the translocation of microencapsulated cyfluthrin following applications to the perimeter of residential dwellings.

    PubMed

    Stout, D M; Leidy, R B

    2000-07-01

    Methods have been developed to monitor the translocation of microencapsulated cyfluthrin following perimeter applications to residential dwellings. A pilot study was implemented to determine both the potential for application spray to drift away from dwellings and the intrusion of residues into homes following perimeter treatments. Residential monitoring included measuring spray drift using cellulose filter paper and the collection of soil samples from within the spray zone. In addition, interior air was monitored using fiberglass filter paper as a sorbent medium and cotton ball swabs were used to collect surface wipes. Fortification of matrixes resulted in recoveries of > 90%. Spray drift was highest at the point of application and declined to low but measurable levels 9.1 m from the foundations of dwellings. Soil residues declined to low, but measurable levels by 45 days post-application. No cyfluthrin was measured from indoor air; however, some interior surfaces had detectable levels of cyfluthrin until three days post-application. Findings indicate that spray drift resulting from perimeter applications might contaminate non-target surfaces outside the spray zone. Soil borne residues may serve as persistent sources for human exposure and potentially intrude into dwellings through the activities of occupants and pets. Residues do not appreciably translocate through air and consequently inhalation is not a likely route for human exposure. Surface residues detected indoors suggest that the physical movement of residues from the exterior to the interior might be a viable route of movement of residues following this type of application.

  1. Relative and contextual contribution of different sources to the composition and abundance of indoor air bacteria in residences.

    PubMed

    Miletto, Marzia; Lindow, Steven E

    2015-12-10

    The study of the microbial communities in the built environment is of critical importance as humans spend the majority of their time indoors. While the microorganisms in living spaces, especially those in the air, can impact health and well-being, little is known of their identity and the processes that determine their assembly. We investigated the source-sink relationships of airborne bacteria in 29 homes in the San Francisco Bay Area. Samples taken in the sites expected to be source habitats for indoor air microbes were analyzed by 16S rRNA-based pyrosequencing and quantitative PCR. The community composition was related to the characteristics of the household collected at the time of sampling, including the number of residents and pets, activity levels, frequency of cooking and vacuum cleaning, extent of natural ventilation, and abundance and type of vegetation surrounding the building. Indoor air harbored a diverse bacterial community dominated by Diaphorobacter sp., Propionibacterium sp., Sphingomonas sp., and Alicyclobacillus sp. Source-sink analysis suggested that outdoor air was the primary source of indoor air microbes in most homes. Bacterial phylogenetic diversity and relative abundance in indoor air did not differ statistically from that in outdoor air. Moreover, the abundance of bacteria in outdoor air was positively correlated with that in indoor air, as would be expected if outdoor air was the main contributor to the bacterial community in indoor bioaerosols. The number of residents, presence of pets, and local tap water also influenced the diversity and size of indoor air microbes. The bacterial load in air increased with the number of residents, activity, and frequency of natural ventilation, and the proportion of bacteria putatively derived from skin increased with the number of residents. Vacuum cleaning increased the signature of pet- and floor-derived bacteria in indoor air, while the frequency of natural ventilation decreased the relative abundance of tap water-derived microorganisms in air. Indoor air in residences harbors a diverse bacterial community originating from both outdoor and indoor sources and is strongly influenced by household characteristics.

  2. Predictors of coarse particulate matter and associated endotoxin concentrations in residential environments

    NASA Astrophysics Data System (ADS)

    Bari, Md. Aynul; MacNeill, Morgan; Kindzierski, Warren B.; Wallace, Lance; Héroux, Marie-Ève; Wheeler, Amanda J.

    2014-08-01

    Exposure to coarse particulate matter (PM), i.e., particles with an aerodynamic diameter between 2.5 and 10 μm (PM10-2.5), is of increasing interest due to the potential for health effects including asthma, allergy and respiratory symptoms. Limited information is available on indoor and outdoor coarse PM and associated endotoxin exposures. Seven consecutive 24-h samples of indoor and outdoor coarse PM were collected during winter and summer 2010 using Harvard Coarse Impactors in a total of 74 Edmonton homes where no reported smoking took place. Coarse PM filters were subsequently analyzed for endotoxin content. Data were also collected on indoor and outdoor temperature, relative humidity, air exchange rate, housing characteristics and occupants' activities. During winter, outdoor concentrations of coarse PM (median = 6.7 μg/m3, interquartile range, IQR = 3.4-12 μg/m3) were found to be higher than indoor concentrations (median 3.4 μg/m3, IQR = 1.6-5.7 μg/m3); while summer levels of indoor and outdoor concentrations were similar (median 4.5 μg/m3, IQR = 2.3-6.8 μg/m3, and median 4.7 μg/m3, IQR = 2.1-7.9 μg/m3, respectively). Similar predictors were identified for indoor coarse PM in both seasons and included corresponding outdoor coarse PM concentrations, whether vacuuming, sweeping or dusting was performed during the sampling period, and number of occupants in the home. Winter indoor coarse PM predictors also included the number of dogs and indoor endotoxin concentrations. Summer median endotoxin concentrations (indoor: 0.41 EU/m3, outdoor: 0.64 EU/m3) were 4-fold higher than winter concentrations (indoor: 0.12 EU/m3, outdoor: 0.16 EU/m3). Other than outdoor endotoxin concentrations, indoor endotoxin concentration predictors for both seasons were different. Winter endotoxin predictors also included presence of furry pets and whether the vacuum had a high efficiency particulate air (HEPA) filter. Summer endotoxin predictors were problems with mice in the previous 12 months and mean indoor relative humidity levels.

  3. The effect of ventilation on indoor exposure to semivolatile organic compounds.

    PubMed

    Liu, C; Zhang, Y; Benning, J L; Little, J C

    2015-06-01

    A mechanistic model was developed to examine how natural ventilation influences residential indoor exposure to semivolatile organic compounds (SVOCs) via inhalation, dermal sorption, and dust ingestion. The effect of ventilation on indoor particle mass concentration and mass transfer at source/sink surfaces, and the enhancing effect of particles on mass transfer at source/sink surfaces are included. When air exchange rate increases from 0.6/h to 1.8/h, the steady-state SVOC (gas-phase plus particle phase with log KOA varying from 9 to 13) concentration in the idealized model decreases by about 60%. In contrast, for the same change in ventilation, the simulated indoor formaldehyde (representing volatile organic compounds) gas-phase concentration decreases by about 70%. The effect of ventilation on exposure via each pathway has a relatively insignificant association with the KOA of the SVOCs: a change of KOA from 10(9) to 10(13) results in a change of only 2-30%. Sensitivity analysis identifies the deposition rate of PM2.5 as a primary factor influencing the relationship between ventilation and exposure for SVOCs with log KOA = 13. The relationship between ventilation rate and air speed near surfaces needs to be further substantiated. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Desorption of SVOCs from Heated Surfaces in the Form of Ultrafine Particles.

    PubMed

    Wallace, Lance A; Ott, Wayne R; Weschler, Charles J; Lai, Alvin C K

    2017-02-07

    Ultrafine particles (UFP) produced by electric heating of stoves and metal cooking pans, absent food, have been hypothesized to be created from a surface film of semivolatile organic compounds (SVOCs) sorbed from the surrounding air. This study tests that hypothesis by size-resolved measurements extending the lower range of the UFP studied from 10 to 2.3 nm, and including other surfaces (glass, aluminum, and porcelain). Heating glass Petri dishes or squares of aluminum foil to about 350-400 °C for 4-6 min removed all sorbed organic substances completely. Subsequent exposure of these "clean" Petri dishes and foil squares to indoor air in two different residences for successively longer periods (1 h to 281 days), followed by heating the materials for 4-6 min, indicated a strong relationship of the number, size distribution, and mass of the UFP to the time exposed. Estimates of the accumulation rate of SVOCs on surfaces were similar to those in studies of organic film buildup on indoor windows. Transfer of skin oils by touching the glass or foil surfaces, or after washing the glass surface with detergent and bare hands, was also observed, with measured particle production comparable with that produced by long-term exposure to indoor air.

  5. Rate and reaction probability of the surface reaction between ozone and dihydromyrcenol measured in a bench scale reactor and a room-sized chamber

    NASA Astrophysics Data System (ADS)

    Shu, Shi; Morrison, Glenn C.

    2012-02-01

    Low volatility terpenoids emitted from consumer products can react with ozone on surfaces and may significantly alter concentrations of ozone, terpenoids and reaction products in indoor air. We measured the reaction probability and a second-order surface-specific reaction rate for the ozonation of dihydromyrcenol, a representative indoor terpenoid, adsorbed onto polyvinylchloride (PVC), glass, and latex paint coated spheres. The reaction probability ranged from (0.06-8.97) × 10 -5 and was very sensitive to humidity, substrate and mass adsorbed. The average surface reaction probability is about 10 times greater than that for the gas-phase reaction. The second-order surface-specific rate coefficient ranged from (0.32-7.05) × 10 -15 cm 4 s -1 molecule -1and was much less sensitive to humidity, substrate, or mass adsorbed. We also measured the ozone deposition velocity due to adsorbed dihydromyrcenol on painted drywall in a room-sized chamber, Based on that, we calculated the rate coefficient ((0.42-1.6) × 10 -15 cm 4 molecule -1 s -1), which was consistent with that derived from bench-scale experiments for the latex paint under similar conditions. We predict that more than 95% of dihydromyrcenol oxidation takes place on indoor surfaces, rather than in building air.

  6. Comparison of latex body paint with wetted gauze wipes for sampling the chemical warfare agents VX and sulfur mustard from common indoor surfaces.

    PubMed

    Hernon-Kenny, Laura A; Behringer, Deborah L; Crenshaw, Michael D

    2016-05-01

    Comparison of solvent-wetted gauze with body paint, a peelable surface sampling media, for the sampling of the chemical warfare agents VX and sulfur mustard from nine surfaces was performed. The nine surfaces sampled are those typical of interior public venues and include smooth, rough, porous, and non-porous surfaces. Overall, solvent-wetted gauze (wipes) performed better for the recovery of VX from non-porous surfaces while body paint (BP) performed better for the porous surfaces. The average percent VX recoveries using wipes and BP, respectively, are: finished wood flooring, 86.2%, 71.4%; escalator handrail, 47.3%, 26.7%; stainless steel, 80.5%, 56.1%; glazed ceramic tile, 81.8%, 44.9%; ceiling tile, 1.77%, 13.1%; painted drywall 7.83%, 21.1%; smooth cement, 0.64%, 10.3%; upholstery fabric, 24.6%, 23.1%; unfinished wood flooring, 9.37%, 13.1%. Solvent-wetted gauze performed better for the recovery of sulfur mustard from three of the relatively non-porous surfaces while body paint performed better for the more porous surfaces. The average percent sulfur mustard recoveries using wipes and BP, respectively, are: finished wood flooring, 30.2%, 2.97%; escalator handrail, 4.40%, 4.09%; stainless steel, 21.2%, 3.30%; glazed ceramic tile, 49.7%, 16.7%; ceiling tile, 0.33%, 11.1%; painted drywall 2.05%, 10.6%; smooth cement, 1.20%, 35.2%; upholstery fabric, 7.63%, 6.03%; unfinished wood flooring, 0.90%, 1.74%. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Environmental tobacco smoke aerosol in non-smoking households of patients with chronic respiratory diseases

    NASA Astrophysics Data System (ADS)

    Chalbot, Marie-Cecile; Vei, Ino-Christina; Lianou, Maria; Kotronarou, Anastasia; Karakatsani, Anna; Katsouyanni, Klea; Hoek, Gerard; Kavouras, Ilias G.

    2012-12-01

    Fine particulate matter samples were collected in an urban ambient fixed site and, outside and inside residencies in Athens greater area, Greece. n-Alkanes, iso/anteiso-alkanes and polycyclic aromatic hydrocarbons (PAHs) were identified by gas chromatography and mass spectrometry. The values of concentration diagnostic ratios indicated a mixture of vehicular emissions, fuel evaporation, oil residues and environmental tobacco smoke (ETS) in outdoor and indoor samples. Particulate iso/anteiso-alkanes, specific tracers of ETS, were detected in both non-smoking and smoking households. The indoor-to-outdoor ratios of particulate iso/anteiso-alkanes and unresolved complex mixture (a tracer of outdoor air pollution) in non-smoking households were comparable to the measured air exchange rate. This suggested that penetration of outdoor air was solely responsible for the detection of tobacco smoke particulate tracers in indoor non-smoking environments. Overall, residential outdoor concentrations accounted for a large fraction (from 25 up to 79%) of indoor aliphatic and polyaromatic hydrocarbons. Open windows/doors and the operation of an air condition unit yielded also in higher indoor concentrations than those measured outdoors.

  8. Fipronil and its degradates in indoor and outdoor dust

    USGS Publications Warehouse

    Mahler, B.J.; Van Metre, P.C.; Wilson, J.T.; Musgrove, M.; Zaugg, S.D.; Burkhardt, M.R.

    2009-01-01

    Fipronil is a potent insecticide used for control of termites, fleas, roaches, ants, and other pests. We measured fipronil, fipronil sulfide, and desulfinyl fipronil concentrations in indoor and outdoor dust from 24 residences in Austin, Texas. At least one of these three fipronil compounds was detected in every sample. Fipronil accounted for most of the total fipronil (T-fipronil; fipronil+desulfinyl fipronil+fipronil sulfide), followed by desulfinyl fipronil and fipronil sulfide. Nineteen of 24 samples of indoor dust had T-fipronil concentrations less than 270 ??g/kg; the remaining five had concentrations from 1320 to 14,200 ??g/kg. All three of the residences with a dog on which a flea-control product containing fipronil was used were among the five residences with elevated fipronil concentrations. In outdoor dust, all concentrations of T-fipronil were less than 70??g/kg with one exception (430??g/kg). For every residence, the concentration of T-fipronil in indoor dust exceeded that in outdoor dust, and the median concentration of T-fipronil was 15 times higher indoors than outdoors.

  9. Chamber Bioaerosol Study: Outdoor Air and Human Occupants as Sources of Indoor Airborne Microbes

    PubMed Central

    Adams, Rachel I.; Bhangar, Seema; Pasut, Wilmer; Arens, Edward A.; Taylor, John W.; Lindow, Steven E.; Nazaroff, William W.; Bruns, Thomas D.

    2015-01-01

    Human occupants are an important source of microbes in indoor environments. In this study, we used DNA sequencing of filter samples to assess the fungal and bacterial composition of air in an environmental chamber under different levels of occupancy, activity, and exposed or covered carpeting. In this office-like, mechanically ventilated environment, results showed a strong influence of outdoor-derived particles, with the indoor microbial composition tracking that of outdoor air for the 2-hour sampling periods. The number of occupants and their activity played a significant but smaller role influencing the composition of indoor bioaerosols. Human-associated taxa were observed but were not particularly abundant, except in the case of one fungus that appeared to be transported into the chamber on the clothing of a study participant. Overall, this study revealed a smaller signature of human body-associated taxa than had been expected based on recent studies of indoor microbiomes, suggesting that occupants may not exert a strong influence on bioaerosol microbial composition in a space that, like many offices, is well ventilated with air that is moderately filtered and moderately occupied. PMID:26024222

  10. Performance Characterization of Dye-Sensitized Photovoltaics under Indoor Lighting.

    PubMed

    Chen, Chia-Yuan; Jian, Zih-Hong; Huang, Shih-Han; Lee, Kun-Mu; Kao, Ming-Hsuan; Shen, Chang-Hong; Shieh, Jia-Min; Wang, Chin-Li; Chang, Chiung-Wen; Lin, Bo-Zhi; Lin, Ching-Yao; Chang, Ting-Kuang; Chi, Yun; Chi, Cheng-Yu; Wang, Wei-Ting; Tai, Yian; Lu, Ming-De; Tung, Yung-Liang; Chou, Po-Ting; Wu, Wen-Ti; Chow, Tahsin J; Chen, Peter; Luo, Xiang-Hao; Lee, Yuh-Lang; Wu, Chih-Chung; Chen, Chih-Ming; Yeh, Chen-Yu; Fan, Miao-Syuan; Peng, Jia-De; Ho, Kuo-Chuan; Liu, Yu-Nan; Lee, Hsiao-Yi; Chen, Chien-Yu; Lin, Hao-Wu; Yen, Chia-Te; Huang, Yu-Ching; Tsao, Cheng-Si; Ting, Yu-Chien; Wei, Tzu-Chien; Wu, Chun-Guey

    2017-04-20

    Indoor utilization of emerging photovoltaics is promising; however, efficiency characterization under room lighting is challenging. We report the first round-robin interlaboratory study of performance measurement for dye-sensitized photovoltaics (cells and mini-modules) and one silicon solar cell under a fluorescent dim light. Among 15 research groups, the relative deviation in power conversion efficiency (PCE) of the samples reaches an unprecedented 152%. On the basis of the comprehensive results, the gap between photometry and radiometry measurements and the response of devices to the dim illumination are identified as critical obstacles to the correct PCE. Therefore, we use an illuminometer as a prime standard with a spectroradiometer to quantify the intensity of indoor lighting and adopt the reverse-biased current-voltage (I-V) characteristics as an indicator to qualify the I-V sampling time for dye-sensitized photovoltaics. The recommendations can brighten the prospects of emerging photovoltaics for indoor applications.

  11. Determination of the Efficacy of Two Building Decontamination Strategies by Surface Sampling with Culture and Quantitative PCR Analysis

    PubMed Central

    Buttner, Mark P.; Cruz, Patricia; Stetzenbach, Linda D.; Klima-Comba, Amy K.; Stevens, Vanessa L.; Cronin, Tracy D.

    2004-01-01

    The efficacy of currently available decontamination strategies for the treatment of indoor furnishings contaminated with bioterrorism agents is poorly understood. Efficacy testing of decontamination products in a controlled environment is needed to ensure that effective methods are used to decontaminate domestic and workplace settings. An experimental room supplied with materials used in office furnishings (i.e., wood laminate, painted metal, and vinyl tile) was used with controlled dry aerosol releases of endospores of Bacillus atrophaeus (“Bacillus subtilis subsp. niger,” also referred to as BG), a Bacillus anthracis surrogate. Studies were performed using two test products, a foam decontaminant and chlorine dioxide gas. Surface samples were collected pre- and posttreatment with three sampling methods and analyzed by culture and quantitative PCR (QPCR). Additional aerosol releases with environmental background present on the surface materials were also conducted to determine if there was any interference with decontamination or sample analysis. Culture results indicated that 105 to 106 CFU per sample were present on surfaces before decontamination. After decontamination with the foam, no culturable B. atrophaeus spores were detected. After decontamination with chlorine dioxide gas, no culturable B. atrophaeus was detected in 24 of 27 samples (89%). However, QPCR analysis showed that B. atrophaeus DNA was still present after decontamination with both methods. Environmental background material had no apparent effect on decontamination, but inhibition of the QPCR assay was observed. These results demonstrate the effectiveness of two decontamination methods and illustrate the utility of surface sampling and QPCR analysis for the evaluation of decontamination strategies. PMID:15294810

  12. Determination of the efficacy of two building decontamination strategies by surface sampling with culture and quantitative PCR analysis.

    PubMed

    Buttner, Mark P; Cruz, Patricia; Stetzenbach, Linda D; Klima-Comba, Amy K; Stevens, Vanessa L; Cronin, Tracy D

    2004-08-01

    The efficacy of currently available decontamination strategies for the treatment of indoor furnishings contaminated with bioterrorism agents is poorly understood. Efficacy testing of decontamination products in a controlled environment is needed to ensure that effective methods are used to decontaminate domestic and workplace settings. An experimental room supplied with materials used in office furnishings (i.e., wood laminate, painted metal, and vinyl tile) was used with controlled dry aerosol releases of endospores of Bacillus atrophaeus ("Bacillus subtilis subsp. niger," also referred to as BG), a Bacillus anthracis surrogate. Studies were performed using two test products, a foam decontaminant and chlorine dioxide gas. Surface samples were collected pre- and posttreatment with three sampling methods and analyzed by culture and quantitative PCR (QPCR). Additional aerosol releases with environmental background present on the surface materials were also conducted to determine if there was any interference with decontamination or sample analysis. Culture results indicated that 10(5) to 10(6) CFU per sample were present on surfaces before decontamination. After decontamination with the foam, no culturable B. atrophaeus spores were detected. After decontamination with chlorine dioxide gas, no culturable B. atrophaeus was detected in 24 of 27 samples (89%). However, QPCR analysis showed that B. atrophaeus DNA was still present after decontamination with both methods. Environmental background material had no apparent effect on decontamination, but inhibition of the QPCR assay was observed. These results demonstrate the effectiveness of two decontamination methods and illustrate the utility of surface sampling and QPCR analysis for the evaluation of decontamination strategies.

  13. Airborne particulate matter in school classrooms of northern Italy.

    PubMed

    Rovelli, Sabrina; Cattaneo, Andrea; Nuzzi, Camilla P; Spinazzè, Andrea; Piazza, Silvia; Carrer, Paolo; Cavallo, Domenico M

    2014-01-27

    Indoor size-fractioned particulate matter (PM) was measured in seven schools in Milan, to characterize their concentration levels in classrooms, compare the measured concentrations with the recommended guideline values, and provide a preliminary assessment of the efficacy of the intervention measures, based on the guidelines developed by the Italian Ministry of Healthand applied to mitigate exposure to undesirable air pollutants. Indoor sampling was performed from Monday morning to Friday afternoon in three classrooms of each school and was repeated in winter 2011-2012 and 2012-2013. Simultaneously, PM2.5 samples were also collected outdoors. Two different photometers were used to collect the PM continuous data, which were corrected a posteriori using simultaneous gravimetric PM2.5 measurements. Furthermore, the concentrations of carbon dioxide (CO2) were monitored and used to determine the Air Exchange Rates in the classrooms. The results revealed poor IAQ in the school environment. In several cases, the PM2.5 and PM10 24 h concentrations exceeded the 24 h guideline values established by the World Health Organization (WHO). In addition, the indoor CO2 levels often surpassed the CO2 ASHRAE Standard. Our findings confirmed that important indoor sources (human movements, personal clouds, cleaning activities) emitted coarse particles, markedly increasing the measured PM during school hours. In general, the mean PM2.5 indoor concentrations were lower than the average outdoor PM2.5 levels, with I/O ratios generally <1. Fine PM was less affected by indoor sources, exerting a major impact on the PM1-2.5 fraction. Over half of the indoor fine particles were estimated to originate from outdoors. To a first approximation, the intervention proposed to reduce indoor particle levels did not seem to significantly influence the indoor fine PM concentrations. Conversely, the frequent opening of doors and windows appeared to significantly contribute to the reduction of the average indoor CO2 levels.

  14. Impact of reaction products from building materials and furnishings on indoor air quality—A review of recent advances in indoor chemistry

    NASA Astrophysics Data System (ADS)

    Uhde, E.; Salthammer, T.

    The variety of chemical substances present in modern building products, household products and furnishings provides potential for chemical reactions in the material (case 1), on the material surface (case 2) and in the gas phase (case 3). Such "indoor chemistry" is known as one of the main reasons for primary and secondary emissions. The conditions of production often cause unwanted side reactions and a number of new compounds can be found in finished products. Elevated temperatures are responsible for the degradation of cellulose, decomposition of non-heat-resistant additives and other thermally induced reactions like Diels-Alder synthesis. Heterogeneous chemistry takes place on the surface of materials. Well-known examples are the formation of aliphatic aldehydes from the oxidation of unsaturated fatty acids or the cleavage of photoinitiators under the influence of light. In case of composite flooring structures hydrolysis is one of the major pathways for the appearance of alcohols from esters. If different kinds of material are fixed together, emissions of new VOCs formed by inter-species reactions are possible. Other indoor air pollutants are formed by rearrangement of cleavage products or by metabolism. Compounds with -C dbnd C- bonds like terpenes, styrene, 4-phenylcyclohexene, etc. undergo gas phase reactions with O 3, NO x, OH and other reactive gases. It has been shown that such products derived from indoor-related reactions may have a negative impact on indoor air quality due to their low odor threshold or health-related properties. Therefore, the understanding of primary and secondary emissions and the chemical processes behind is essential for the evaluation of indoor air quality. This publication gives an overview on the current state of research and new findings regarding primary and secondary emissions from building products and furnishings.

  15. Semantic Segmentation of Indoor Point Clouds Using Convolutional Neural Network

    NASA Astrophysics Data System (ADS)

    Babacan, K.; Chen, L.; Sohn, G.

    2017-11-01

    As Building Information Modelling (BIM) thrives, geometry becomes no longer sufficient; an ever increasing variety of semantic information is needed to express an indoor model adequately. On the other hand, for the existing buildings, automatically generating semantically enriched BIM from point cloud data is in its infancy. The previous research to enhance the semantic content rely on frameworks in which some specific rules and/or features that are hand coded by specialists. These methods immanently lack generalization and easily break in different circumstances. On this account, a generalized framework is urgently needed to automatically and accurately generate semantic information. Therefore we propose to employ deep learning techniques for the semantic segmentation of point clouds into meaningful parts. More specifically, we build a volumetric data representation in order to efficiently generate the high number of training samples needed to initiate a convolutional neural network architecture. The feedforward propagation is used in such a way to perform the classification in voxel level for achieving semantic segmentation. The method is tested both for a mobile laser scanner point cloud, and a larger scale synthetically generated data. We also demonstrate a case study, in which our method can be effectively used to leverage the extraction of planar surfaces in challenging cluttered indoor environments.

  16. Elemental mercury emission in the indoor environment due to broken compact fluorescent light (CFL) bulbs--paper

    EPA Science Inventory

    Compact fluorescent light (CFL) bulbs contain a few milligrams (mg) of elemental mercury. When a CFL breaks, some of the mercury is immediately released as elemental mercury vapor and the remainder is deposited on indoor surfaces with the bulb debris. In a controlled study design...

  17. Providing pressure inputs to multizone building models

    DOE PAGES

    Herring, Steven J.; Batchelor, Simon; Bieringer, Paul E.; ...

    2016-02-13

    A study to assess how the fidelity of wind pressure inputs and indoor model complexity affect the predicted air change rate for a study building is presented. The purpose of the work is to support the development of a combined indoor-outdoor hazard prediction tool, which links the CONTAM multizone building simulation tool with outdoor dispersion models. The study building, representing a large office block of a simple rectangular geometry under natural ventilation, was based on a real building used in the Joint Urban 2003 experiment. A total of 1600 indoor model flow simulations were made, driven by 100 meteorological conditionsmore » which provided a wide range of building surface pressures. These pressures were applied at four levels of resolution to four different building configurations with varying numbers of internal zones and indoor and outdoor flow paths. Analysis of the results suggests that surface pressures and flow paths across the envelope should be specified at a resolution consistent with the dimensions of the smallest volume of interest, to ensure that appropriate outputs are obtained.« less

  18. Per- and polyfluorinated compounds (PFCs) in house dust and indoor air in Catalonia, Spain: implications for human exposure.

    PubMed

    Ericson Jogsten, I; Nadal, M; van Bavel, B; Lindström, G; Domingo, J L

    2012-02-01

    A total of 27 per- and polyfluorinated compounds (PFCs) were determined in both house dust (n=10) and indoor air (n=10) from selected homes in Catalonia, Spain. Concentrations were found to be similar or lower than those previously reported for household microenvironments in other countries. Ten PFCs were detected in all house dust samples. The highest mean concentrations corresponded to perfluorodecanoic acid (PFDA) and perfluorononanoic acid (PFNA), 10.7 ng/g (median: 1.5 ng/g) and 10.4 ng/g (median: 5.4 ng/g), respectively, while the 8:2 fluorotelomer alcohol (FTOH) was the dominating neutral PFC at a concentration of 0.41 ng/g (median: 0.35 ng/g). The indoor air was dominated by the FTOHs, especially the 8:2 FTOH at a mean (median) concentration of 51 pg/m(3) (median: 42 pg/m(3)). A limited number of ionic PFCs were also detected in the indoor air samples. Daily intakes of PFCs were estimated for average and worst case scenarios of human exposure from indoor sources. For toddlers, this resulted in average intakes of ∑ionic PFCs of 4.9ng/day (0.33 ng/kg(bw)/day for a 15 kg toddlers) and ∑neutral PFCs of 0.072 ng/day (0.005 ng/kg(bw)/day) from house dust. For adults, the average daily intakes of dust were 3.6 and 0.053 ng/day (0.05 and 0.001 ng/kg(bw)/day for a 70 kg adult) for ∑ionic and ∑neutral PFCs, respectively. The average daily inhalation of ∑neutral PFCs was estimated to be 0.9 and 1.3 ng/day (0.06 and 0.02 ng/kg(bw)/day) for toddlers and adults, respectively. For PFOS, the main ionic PFC detected in indoor air samples, the median intakes (based on those samples where PFOS was detected), resulted in indoor exposures of 0.06 and 0.11 ng/day (0.004 and 0.002 ng/kg(bw)/day) for toddlers and adults, respectively. Based on previous studies on dietary intake and drinking water consumption, both house dust and indoor air contribute significantly less to PFC exposure within this population. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Relationship of Indoor, Outdoor and Personal Air (RIOPA) study: study design, methods and quality assurance/control results.

    PubMed

    Weisel, Clifford P; Zhang, Junfeng; Turpin, Barbara J; Morandi, Maria T; Colome, Steven; Stock, Thomas H; Spektor, Dalia M; Korn, Leo; Winer, Arthur; Alimokhtari, Shahnaz; Kwon, Jaymin; Mohan, Krishnan; Harrington, Robert; Giovanetti, Robert; Cui, William; Afshar, Masoud; Maberti, Silvia; Shendell, Derek

    2005-03-01

    The Relationship of Indoor, Outdoor and Personal Air (RIOPA) Study was undertaken to evaluate the contribution of outdoor sources of air toxics, as defined in the 1990 Clean Air Act Amendments, to indoor concentrations and personal exposures. The concentrations of 18 volatile organic compounds (VOCs), 17 carbonyl compounds, and fine particulate matter mass (PM(2.5)) were measured using 48-h outdoor, indoor and personal air samples collected simultaneously. PM2.5 mass, as well as several component species (elemental carbon, organic carbon, polyaromatic hydrocarbons and elemental analysis) were also measured; only PM(2.5) mass is reported here. Questionnaires were administered to characterize homes, neighborhoods and personal activities that might affect exposures. The air exchange rate was also measured in each home. Homes in close proximity (<0.5 km) to sources of air toxics were preferentially (2:1) selected for sampling. Approximately 100 non-smoking households in each of Elizabeth, NJ, Houston, TX, and Los Angeles, CA were sampled (100, 105, and 105 respectively) with second visits performed at 84, 93, and 81 homes in each city, respectively. VOC samples were collected at all homes, carbonyls at 90% and PM(2.5) at 60% of the homes. Personal samples were collected from nonsmoking adults and a portion of children living in the target homes. This manuscript provides the RIOPA study design and quality control and assurance data. The results from the RIOPA study can potentially provide information on the influence of ambient sources on indoor air concentrations and exposure for many air toxics and will furnish an opportunity to evaluate exposure models for these compounds.

  20. Indoor chemistry: research opportunities and challenges.

    PubMed

    Nazaroff, W W; Goldstein, A H

    2015-08-01

    In this editorial, we have highlighted key research opportunities and challenges in four topical themes for indoor chemistry: human occupants as agents influencing indoor chemistry; oxidative chemistry; surface phenomena; and semivolatile organic compounds. In each case, enough prior work has been done to demonstrate the importance of the theme and to create a foundation for future studies. Extensive achievements and ongoing progress in (outdoor) atmospheric chemistry—both in the analytical methods developed and in the scientific knowledge created—also contribute to a strong foundation from which to achieve rapid research progress in this exciting new domain.

  1. [Sampling of allergens in dust deposited in the workplace].

    PubMed

    Perfetti, L; Galdi, E; Pozzi, V; Moscato, G

    2001-01-01

    Some workplaces share with domestic dwellings many characteristics favouring house dust mite growth. Moreover it has recently been shown that pets owners can bring allergens to public places with their clothes. So it is possible that significant exposure to indoor allergens can occur outside homes, at the workplace. The recent availability of immunoassays with monoclonal antibodies for indoor allergens has enabled many investigators to quantify exposure to such allergens in epidemiological studies. Analysis of allergens in settled dust is a simple method of quantification exposure to indoor allergens. The concentrations of indoor allergens in public places have already been investigated and high levels of indoor allergens have been reported. A study performed by our group in offices (banks and media) in different regions of Italy has also shown significant levels of indoor allergens. Thus, evaluating exposure to indoor allergens at the workplace is critical to evaluate risk factors for sensitization and elicitation of symptoms in sensitized subjects and such data help in addressing correctly the problem of reducing exposure levels.

  2. DNA accumulation on ventilation system filters in university buildings in Singapore

    PubMed Central

    Luhung, Irvan; Wu, Yan; Xu, Siyu; Yamamoto, Naomichi; Nazaroff, William W.

    2017-01-01

    Introduction Biological particles deposit on air handling system filters as they process air. This study reports and interprets abundance and diversity information regarding biomass accumulation on ordinarily used filters acquired from several locations in a university environment. Methods DNA-based analysis was applied both to quantify (via DNA fluorometry and qPCR) and to characterize (via high-throughput sequencing) the microbial material on filters, which mainly processed recirculated indoor air. Results were interpreted in relation to building occupancy and ventilation system operational parameters. Results Based on accumulated biomass, average DNA concentrations per AHU filter surface area across nine indoor locations after twelve weeks of filter use were in the respective ranges 1.1 to 41 ng per cm2 for total DNA, 0.02 to 3.3 ng per cm2 for bacterial DNA and 0.2 to 2.0 ng DNA per cm2 for fungal DNA. The most abundant genera detected on the AHU filter samples were Clostridium, Streptophyta, Bacillus, Acinetobacter and Ktedonobacter for bacteria and Aspergillus, Cladosporium, Nigrospora, Rigidoporus and Lentinus for fungi. Conditional indoor airborne DNA concentrations (median (range)) were estimated to be 13 (2.6–107) pg/m3 for total DNA, 0.4 (0.05–8.4) pg/m3 for bacterial DNA and 2.3 (1.0–5.1) pg/m3 for fungal DNA. Conclusion Conditional airborne concentrations and the relative abundances of selected groups of genera correlate well with occupancy level. Bacterial DNA was found to be more responsive than fungal DNA to differences in occupancy level and indoor environmental conditions. PMID:29023520

  3. Characterizing the bacterial communities in retail stores in the United States.

    PubMed

    Hoisington, A; Maestre, J P; Kinney, K A; Siegel, J A

    2016-12-01

    The microorganisms present in retail environments have not been studied in detail despite the fact that these environments represent a potentially important location for exposure. In this study, HVAC filter dust samples in 13 US retail stores were collected and analyzed via pyrosequencing to characterize the indoor bacterial communities and to explore potential relationships between these communities and building and environmental parameters. Although retail stores contained a diverse bacterial community of 788 unique genera, over half of the nearly 118K sequences were attributed to the Proteobacteria phylum. Streptophyta, Bacillus, Corynebacterium, Pseudomonas, and Acinetobacter were the most prevalent genera detected. The recovered indoor airborne microbial community was statistically associated with both human oral and skin microbiota, indicating occupants are important contributors, despite a relatively low occupant density per unit volume in retail stores. Bacteria generally associated with outdoor environments were present in the indoor communities with no obvious association with air exchange rate, even when considering relative abundance. No significant association was observed between the indoor bacterial community recovered and store location, store type, or season. However, predictive functional gene profiling showed significant associations between the indoor community and season. The microbiome recovered from multiple samples collected months apart from the same building varied significantly indicating that caution is warranted when trying to characterize the bacterial community with a single sampling event. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Three-dimensional reconstruction of indoor whole elements based on mobile LiDAR point cloud data

    NASA Astrophysics Data System (ADS)

    Gong, Yuejian; Mao, Wenbo; Bi, Jiantao; Ji, Wei; He, Zhanjun

    2014-11-01

    Ground-based LiDAR is one of the most effective city modeling tools at present, which has been widely used for three-dimensional reconstruction of outdoor objects. However, as for indoor objects, there are some technical bottlenecks due to lack of GPS signal. In this paper, based on the high-precision indoor point cloud data which was obtained by LiDAR, an international advanced indoor mobile measuring equipment, high -precision model was fulfilled for all indoor ancillary facilities. The point cloud data we employed also contain color feature, which is extracted by fusion with CCD images. Thus, it has both space geometric feature and spectral information which can be used for constructing objects' surface and restoring color and texture of the geometric model. Based on Autodesk CAD platform and with help of PointSence plug, three-dimensional reconstruction of indoor whole elements was realized. Specifically, Pointools Edit Pro was adopted to edit the point cloud, then different types of indoor point cloud data was processed, including data format conversion, outline extracting and texture mapping of the point cloud model. Finally, three-dimensional visualization of the real-world indoor was completed. Experiment results showed that high-precision 3D point cloud data obtained by indoor mobile measuring equipment can be used for indoor whole elements' 3-d reconstruction and that methods proposed in this paper can efficiently realize the 3 -d construction of indoor whole elements. Moreover, the modeling precision could be controlled within 5 cm, which was proved to be a satisfactory result.

  5. Airborne particle-bound brominated flame retardants: Levels, size distribution and indoor-outdoor exchange.

    PubMed

    Zhu, Yue-Shan; Yang, Wan-Dong; Li, Xiu-Wen; Ni, Hong-Gang; Zeng, Hui

    2018-02-01

    The quality of indoor environments has a significant impact on public health. Usually, an indoor environment is treated as a static box, in which physicochemical reactions of indoor air contaminants are negligible. This results in conservative estimates for primary indoor air pollutant concentrations, while also ignoring secondary pollutants. Thus, understanding the relationship between indoor and outdoor particles and particle-bound pollutants is of great significance. For this reason, we collected simultaneous indoor and outdoor measurements of the size distribution of airborne brominated flame retardant (BFR) congeners. The time-dependent concentrations of indoor particles and particle-bound BFRs were then estimated with the mass balance model, accounting for the outdoor concentration, indoor source strength, infiltration, penetration, deposition and indoor resuspension. Based on qualitative observation, the size distributions of ΣPBDE and ΣHBCD were characterized by bimodal peaks. According to our results, particle-bound BDE209 and γ-HBCD underwent degradation. Regardless of the surface adsorption capability of particles and the physicochemical properties of the target compounds, the concentration of BFRs in particles of different size fractions seemed to be governed by the particle distribution. Based on our estimations, for airborne particles and particle-bound BFRs, a window-open ventilated room only takes a quarter of the time to reach an equilibrium between the concentration of pollutants inside and outside compared to a closed room. Unfortunately, indoor pollutants and outdoor pollutants always exist simultaneously, which poses a window-open-or-closed dilemma to achieve proper ventilation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Stable isotope ratios of marijuana. I. Carbon and nitrogen stable isotopes describe growth conditions.

    PubMed

    West, Jason B; Hurley, Janet M; Ehleringer, James R

    2009-01-01

    There remains significant uncertainty in illicit marijuana cultivation. We analyzed the delta(13)C and delta(15)N of 508 domestic samples from known U.S.A. counties, 31 seized from a single location, 5 samples grown in Mexico and Colombia, and 10 northwest border seizures. For a subset, inflorescences and leaves were analyzed separately. These data revealed a strong correspondence, with inflorescences having slightly higher delta(13)C and delta(15)N values than leaves. A framework for interpreting these results is introduced and evaluated. Samples identified as outdoor-grown by delta(13)C were generally recorded as such by the Drug Enforcement Administration (DEA). DEA-classified indoor-grown samples had the most negative delta(13)C values, consistent with indoor cultivation, although many were also in the outdoor-grown domain. Delta(15)N indicated a wide range of fertilizers across the dataset. Samples seized at the single location suggested multiple sources. Northwest border delta(13)C values suggested indoor growth, whereas for the Mexican and Colombian samples they indicated outdoor growth.

  7. Novel sample preparation technique with needle-type micro-extraction device for volatile organic compounds in indoor air samples.

    PubMed

    Ueta, Ikuo; Mizuguchi, Ayako; Fujimura, Koji; Kawakubo, Susumu; Saito, Yoshihiro

    2012-10-09

    A novel needle-type sample preparation device was developed for the effective preconcentration of volatile organic compounds (VOCs) in indoor air before gas chromatography-mass spectrometry (GC-MS) analysis. To develop a device for extracting a wide range of VOCs typically found in indoor air, several types of particulate sorbents were tested as the extraction medium in the needle-type extraction device. To determine the content of these VOCs, air samples were collected for 30min with the packed sorbent(s) in the extraction needle, and the extracted VOCs were thermally desorbed in a GC injection port by the direct insertion of the needle. A double-bed sorbent consisting of a needle packed with divinylbenzene and activated carbon particles exhibited excellent extraction and desorption performance and adequate extraction capacity for all the investigated VOCs. The results also clearly demonstrated that the proposed sample preparation method is a more rapid, simpler extraction/desorption technique than traditional sample preparation methods. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. SAMPLE DESIGN CONSIDERATIONS FOR INDOOR AIR EXPOSURE SURVEYS

    EPA Science Inventory

    Recent studies have shown that the traditional practice of monitoring outdoor (ambient) air quality leads to little information regarding the exposures of people in indoor surroundings. Consequently, EPA has begun a series of studies to determine the air pollution exposures peopl...

  9. Prevalence of Indoor Tanning and Association With Sunburn Among Youth in the United States.

    PubMed

    Guy, Gery P; Berkowitz, Zahava; Everett Jones, Sherry; Watson, Meg; Richardson, Lisa C

    2017-05-01

    Indoor tanning and sunburns, particularly during adolescence and young adulthood, increase the risk of developing skin cancer. To examine the trends in the prevalence of indoor tanning and the association between indoor tanning and sunburn among US high school students. This study pooled and examined cross-sectional data from the 2009, 2011, 2013, and 2015 national Youth Risk Behavior Survey. During 2009, 2011, 2013, and 2015, the overall response rates were 71%, 71%, 68%, and 60%, respectively, and unweighted sample sizes were 16 410, 15 425, 13 538, and 15 624, respectively. It included nationally representative samples of US high school students. Data were collected during the spring semester (January to June) in each survey cycle beginning February 9, 2009, through June 18, 2015. Prevalence of indoor tanning in the past year from 2009 to 2015 and its association with sunburn in 2015. Among high school students in the United States, the prevalence of indoor tanning decreased from 15.6% (95% CI, 13.7%-17.6%) in 2009 to 7.3% (95% CI, 6.0%-8.9%) in 2015. Decreases in indoor tanning were found among male (from 6.7% in 2009 to 4.0% in 2015) and female (from 25.4 % in 2009 to 10.6 % in 2015) students overall, non-Hispanic white (from 21.1 % in 2009 to 9.4% in 2015) and Hispanic (from 8.2% in 2009 to 4.7% in 2015) students overall, and all age groups. Among non-Hispanic white female students, the prevalence decreased from 37.4% (95% CI, 33.6%-41.4%) in 2009 to 15.2% (95% CI, 11.7%-19.5%) in 2015. In 2015, indoor tanning was associated with sunburn in the adjusted model: 82.3% (95% CI, 77.9%-86.0%) of indoor tanners had at least 1 sunburn during the preceding year compared with 53.7% (95% CI, 48.9%-58.4%) of those who did not engage in indoor tanning (P < .001). Despite declines in the prevalence of indoor tanning from 2009 to 2015 among high school students nationwide, indoor tanning remains commonplace among certain subgroups, especially non-Hispanic white female students. Three-quarters of those who engaged in indoor tanning had experienced at least 1 sunburn. Efforts by the public health and medical communities are needed to further reduce the prevalence of indoor tanning and sunburn and thus prevent future cases of skin cancer.

  10. Prevalence of Indoor Tanning and Association With Sunburn Among Youth in the United States

    PubMed Central

    Berkowitz, Zahava; Everett Jones, Sherry; Watson, Meg; Richardson, Lisa C.

    2017-01-01

    Importance Indoor tanning and sunburns, particularly during adolescence and young adulthood, increase the risk of developing skin cancer. Objective To examine the trends in the prevalence of indoor tanning and the association between indoor tanning and sunburn among US high school students. Design, Setting, and Participants This study pooled and examined cross-sectional data from the 2009, 2011, 2013, and 2015 national Youth Risk Behavior Survey. During 2009, 2011, 2013, and 2015, the overall response rates were 71%, 71%, 68%, and 60%, respectively, and unweighted sample sizes were 16 410, 15 425, 13 538, and 15 624, respectively. It included nationally representative samples of US high school students. Data were collected during the spring semester (January to June) in each survey cycle beginning February 9, 2009, through June 18, 2015. Main Outcomes and Measures Prevalence of indoor tanning in the past year from 2009 to 2015 and its association with sunburn in 2015. Results Among high school students in the United States, the prevalence of indoor tanning decreased from 15.6% (95% CI, 13.7%-17.6%) in 2009 to 7.3% (95% CI, 6.0%-8.9%) in 2015. Decreases in indoor tanning were found among male (from 6.7% in 2009 to 4.0% in 2015) and female (from 25.4 % in 2009 to 10.6 % in 2015) students overall, non-Hispanic white (from 21.1 % in 2009 to 9.4% in 2015) and Hispanic (from 8.2% in 2009 to 4.7% in 2015) students overall, and all age groups. Among non-Hispanic white female students, the prevalence decreased from 37.4% (95% CI, 33.6%-41.4%) in 2009 to 15.2% (95% CI, 11.7%-19.5%) in 2015. In 2015, indoor tanning was associated with sunburn in the adjusted model: 82.3% (95% CI, 77.9%-86.0%) of indoor tanners had at least 1 sunburn during the preceding year compared with 53.7% (95% CI, 48.9%-58.4%) of those who did not engage in indoor tanning (P < .001). Conclusions and Relevance Despite declines in the prevalence of indoor tanning from 2009 to 2015 among high school students nationwide, indoor tanning remains commonplace among certain subgroups, especially non-Hispanic white female students. Three-quarters of those who engaged in indoor tanning had experienced at least 1 sunburn. Efforts by the public health and medical communities are needed to further reduce the prevalence of indoor tanning and sunburn and thus prevent future cases of skin cancer. PMID:28257531

  11. Oxidative potential and chemical composition of PM2.5 in office buildings across Europe - The OFFICAIR study.

    PubMed

    Szigeti, Tamás; Dunster, Christina; Cattaneo, Andrea; Cavallo, Domenico; Spinazzè, Andrea; Saraga, Dikaia E; Sakellaris, Ioannis A; de Kluizenaar, Yvonne; Cornelissen, Eric J M; Hänninen, Otto; Peltonen, Matti; Calzolai, Giulia; Lucarelli, Franco; Mandin, Corinne; Bartzis, John G; Záray, Gyula; Kelly, Frank J

    2016-01-01

    In the frame of the OFFICAIR project, indoor and outdoor PM2.5 samples were collected in office buildings across Europe in two sampling campaigns (summer and winter). The ability of the particles to deplete physiologically relevant antioxidants (ascorbic acid (AA), reduced glutathione (GSH)) in a synthetic respiratory tract lining fluid, i.e., oxidative potential (OP), was assessed. Furthermore, the link between particulate OP and the concentration of the PM constituents was investigated. The mean indoor PM2.5 mass concentration values were substantially lower than the related outdoor values with a mean indoor/outdoor PM2.5 mass concentration ratio of 0.62 and 0.61 for the summer and winter campaigns respectively. The OP of PM2.5 varied markedly across Europe with the highest outdoor OP(AA) m(-3) and OP(GSH) m(-3) (% antioxidant depletion/m(3) air) values obtained for Hungary, while PM2.5 collected in Finland exhibited the lowest values. Seasonal variation could be observed for both indoor and outdoor OP(AA) m(-3) and OP(GSH) m(-3) with higher mean values during winter. The indoor/outdoor OP(AA) m(-3) and OP(GSH) m(-3) ratios were less than one with 4 and 17 exceptions out of the 40 cases respectively. These results indicate that indoor air is generally less oxidatively challenging than outdoors. Correlation analysis revealed that trace elements play an important role in determining OP, in particular, the Cu content. Indoor air chemistry might affect OP since weaker correlations were obtained for indoor PM2.5. Our findings also suggest that office workers may be exposed to health relevant PM constituents to a different extent within the same building. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Comparative assessment of a real-time particle monitor against the reference gravimetric method for PM10 and PM2.5 in indoor air

    NASA Astrophysics Data System (ADS)

    Tasić, Viša; Jovašević-Stojanović, Milena; Vardoulakis, Sotiris; Milošević, Novica; Kovačević, Renata; Petrović, Jelena

    2012-07-01

    Accurate monitoring of indoor mass concentrations of particulate matter is very important for health risk assessment as people in developed countries spend approximately 90% of their time indoors. The direct reading, aerosol monitoring device, Turnkey, OSIRIS Particle Monitor (Model 2315) and the European reference low volume sampler, LVS3 (Sven/Leckel LVS3) with size-selective inlets for PM10 and PM2.5 fractions were used to assess the comparability of available optical and gravimetric methods for particulate matter characterization in indoor air. Simultaneous 24-hour samples were collected in an indoor environment for 60 sampling periods in the town of Bor, Serbia. The 24-hour mean PM10 levels from the OSIRIS monitor were well correlated with the LVS3 levels (R2 = 0.87) and did not show statistically significant bias. The 24-hour mean PM2.5 levels from the OSIRIS monitor were moderately correlated with the LVS3 levels (R2 = 0.71), but show statistically significant bias. The results suggest that the OSIRIS monitor provides sufficiently accurate measurements for PM10. The OSIRIS monitor underestimated the indoor PM10 concentrations by approximately 12%, relative to the reference LVS3 sampler. The accuracy of PM10 measurements could be further improved through empirical adjustment. For the fine fraction of particulate matter, PM2.5, it was found that the OSIRIS monitor underestimated indoor concentrations by approximately 63%, relative to the reference LVS3 sampler. This could lead to exposure misclassification in health effects studies relying on PM2.5 measurements collected with this instrument in indoor environments.

  13. Indoor air pollution and cognitive function among older Mexican adults.

    PubMed

    Saenz, Joseph L; Wong, Rebeca; Ailshire, Jennifer A

    2018-01-01

    A growing body of research suggests exposure to high levels of outdoor air pollution may negatively affect cognitive functioning in older adults, but less is known about the link between indoor sources of air pollution and cognitive functioning. We examine the association between exposure to indoor air pollution and cognitive function among older adults in Mexico, a developing country where combustion of biomass for domestic energy remains common. Data come from the 2012 Wave of the Mexican Health and Aging Study. The analytic sample consists of 13 023 Mexican adults over age 50. Indoor air pollution is assessed by the reported use of wood or coal as the household's primary cooking fuel. Cognitive function is measured with assessments of verbal learning, verbal recall, attention, orientation and verbal fluency. Ordinary least squares regression is used to examine cross-sectional differences in cognitive function according to indoor air pollution exposure while accounting for demographic, household, health and economic characteristics. Approximately 16% of the sample reported using wood or coal as their primary cooking fuel, but this was far more common among those residing in the most rural areas (53%). Exposure to indoor air pollution was associated with poorer cognitive performance across all assessments, with the exception of verbal recall, even in fully adjusted models. Indoor air pollution may be an important factor for the cognitive health of older Mexican adults. Public health efforts should continue to develop interventions to reduce exposure to indoor air pollution in rural Mexico. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Modeling indoor particulate exposures in inner city school classrooms

    PubMed Central

    Gaffin, Jonathan M.; Petty, Carter R.; Hauptman, Marissa; Kang, Choong-Min; Wolfson, Jack M.; Awad, Yara Abu; Di, Qian; Lai, Peggy S.; Sheehan, William J.; Baxi, Sachin; Coull, Brent A.; Schwartz, Joel D.; Gold, Diane R.; Koutrakis, Petros; Phipatanakul, Wanda

    2016-01-01

    Outdoor air pollution penetrates buildings and contributes to total indoor exposures. We investigated the relationship of indoor to outdoor particulate matter in inner-city school classrooms. The School Inner City Asthma Study investigates the effect of classroom-based environmental exposures on students with asthma in the northeast United States. Mixed-effects linear models were used to determine the relationships between indoor PM2.5 and BC and their corresponding outdoor concentrations, and to develop a model for predicting exposures to these pollutants. The indoor-outdoor sulfur ratio was used as an infiltration factor of outdoor fine particles. Weeklong concentrations of PM2.5 and BC in 199 samples from 136 classrooms (30 school buildings) were compared to those measured at a central monitoring site averaged over the same timeframe. Mixed effects regression models found significant random intercept and slope effects, which indicate that: 1) there are important PM2.5 sources in classrooms; 2) the penetration of outdoor PM2.5 particles varies by school, and 3) the site-specific outside PM2.5 levels (inferred by the models) differ from those observed at the central monitor site. Similar results were found for BC except for lack of indoor sources. The fitted predictions from the sulfur-adjusted models were moderately predictive of observed indoor pollutant levels (Out of sample correlations: PM2.5: r2 = 0.68, BC; r2 = 0.61). Our results suggest that PM2.5 has important classroom sources, which vary by school. Furthermore, using these mixed effects models, classroom exposures can be accurately predicted for dates when central site measures are available but indoor measures are not available. PMID:27599884

  15. Development of analysis of volatile polyfluorinated alkyl substances in indoor air using thermal desorption-gas chromatography-mass spectrometry.

    PubMed

    Wu, Yaoxing; Chang, Victor W-C

    2012-05-18

    The study attempts to utilize thermal desorption (TD) coupled with gas chromatography-mass spectrometry (GC-MS) for determination of indoor airborne volatile polyfluorinated alkyl substances (PFASs), including four fluorinated alcohols (FTOHs), two fluorooctane sulfonamides (FOSAs), and two fluorooctane sulfonamidoethanols (FOSEs). Standard stainless steel tubes of Tenax/Carbograph 1 TD were employed for low-volume sampling and exhibited minimal breakthrough of target analytes in sample collection. The method recoveries were in the range of 88-119% for FTOHs, 86-138% for FOSAs, exhibiting significant improvement compared with other existing air sampling methods. However, the widely reported high method recoveries of FOSEs were also observed (139-210%), which was probably due to the structural differences between FOSEs and internal standards. Method detection limit, repeatability, linearity, and accuracy were reported as well. The approach has been successfully applied to routine quantification of targeted PFASs in indoor environment of Singapore. The significantly shorter sampling time enabled the observation of variations of concentrations of targeted PFASs within different periods of a day, with higher concentration levels at night while ventilation systems were shut off. This indicated the existence of indoor sources and the importance of building ventilation and air conditioning system. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Phthalate levels in Norwegian indoor air related to particle size fraction.

    PubMed

    Rakkestad, Kirsten Eline; Dye, Christian Jarle; Yttri, Karl Espen; Holme, Jørn Andreas; Hongslo, Jan Kenneth; Schwarze, Per Everhard; Becher, Rune

    2007-12-01

    Phthalates are found in numerous consumer products, including interior materials like polyvinyl chloride (PVC). Several studies have identified phthalates in indoor air. A recent case-control study demonstrated associations between allergic symptoms in children and the concentration of phthalates in dust collected from their homes. Here we have analyzed the content of selected phthalates in particulate matter (PM): PM(10) and PM(2.5) filter samples collected in 14 different indoor environments. The results showed the presence of the phthalates di-n-butyl phthalate (DBP), butyl benzyl phthalate (BBP), dicyclohexyl phthalate (DCHP) and diethyl hexyl phthalate (DEHP) in the samples. The dominating phthalate in both PM(10) and PM(2.5) samples from all locations was DBP. More than a 10-fold variation in the mean concentration of total phthalates between sampling sites was observed. The highest levels of total phthalates were detected in one children's room, one kindergarten, in two primary schools, and in a computer room. The relative contribution of total phthalates in PM(10) and PM(2.5) was 1.1 +/- 0.3% for both size fractions. The contribution of total phthalates in PM(2.5) to total phthalates in PM(10) ranged from 23-81%, suggesting different sources. Of the phthalates that were analyzed in the PM material, DBP was found to be the major phthalate in rubber from car tyres. However, our analyses indicate that tyre wear was of minor importance for indoor levels of both DBP as well as total phthalates. Overall, these results support the notion that inhalation of indoor PM contributes to the total phthalate exposure.

  17. Monitoring of Microscopic Filamentous Fungi in Indoor Air of Transplant Unit.

    PubMed

    Holý, Ondřej; Matoušková, Ivanka; Kubátová, Alena; Hamal, Petr; Svobodová, Lucie; Jurásková, Eva; Raida, Luděk

    2015-12-01

    The aim of the study was to control the microbial contamination of indoor air monitored monthly at the Transplant Unit of the University Hospital Olomouc from August 2010 to July 2011. The unit is equipped with a three-stage air filtration system with HEPA filters. The MAS-100 air sampler (Merck, GER) was used. Twenty locations were singled out for the purposes of collecting a total of 720 samplings of the indoor air. Swabs of the HVAC diffusers at the sampling locations were always carried out after the sampling of the indoor air. In total, 480 samples of the indoor air were taken for Sabouraud chloramphenicol agar. In 11 cases (2.29%) the cultivation verified the presence of microscopic filamentous fungi. Only two cases involved the sanitary facilities of a patient isolation box; the other positive findings were from the facilities. The most frequent established genus was Aspergillus spp. (4x), followed by Trichoderma spp. (2x) and Penicillium spp. (2x), Paecilomyces spp., Eurotium spp., and Chrysonilia spp. (1x each). In 2 cases the cultivation established sterile aerial mycelium, unfortunately no further identification was possible. A total of 726 swabs of HVAC diffusers were collected (2 positive-0.28%). The study results demonstrated the efficacy of the HVAC equipment. With the continuing increase in the number of severely immunocompromised patients, hospitals are faced with the growing problem of invasive aspergillosis and other opportunistic infections. Preventive monitoring of microbial air contaminants is of major importance for the control of invasive aspergillosis. Copyright© by the National Institute of Public Health, Prague 2015.

  18. Urinary and breast milk biomarkers to assess exposure to naphthalene in pregnant women: an investigation of personal and indoor air sources

    PubMed Central

    2014-01-01

    Background Naphthalene exposures for most non-occupationally exposed individuals occur primarily indoors at home. Residential indoor sources include pest control products (specifically moth balls), incomplete combustion such as cigarette smoke, woodstoves and cooking, some consumer and building products, and emissions from gasoline sources found in attached garages. The study aim was to assess naphthalene exposure in pregnant women from Canada, using air measurements and biomarkers of exposure. Methods Pregnant women residing in Ottawa, Ontario completed personal and indoor air sampling, and questionnaires. During pregnancy, pooled urine voids were collected over two 24-hour periods on a weekday and a weekend day. At 2–3 months post-birth, they provided a spot urine sample and a breast milk sample following the 24-hour air monitoring. Urines were analyzed for 1-naphthol and 2-naphthol and breast milk for naphthalene. Simple linear regression models examined associations between known naphthalene sources, air and biomarker samples. Results Study recruitment rate was 11.2% resulting in 80 eligible women being included. Weekday and weekend samples were highly correlated for both personal (r = 0.83, p < 0.0001) and indoor air naphthalene (r = 0.91, p < 0.0001). Urine specific gravity (SG)-adjusted 2-naphthol concentrations collected on weekdays and weekends (r = 0.78, p < 0.001), and between pregnancy and postpartum samples (r = 0.54, p < 0.001) were correlated. Indoor and personal air naphthalene concentrations were significantly higher post-birth than during pregnancy (p < 0.0001 for signed rank tests); concurrent urine samples were not significantly different. Naphthalene in breast milk was associated with urinary 1-naphthol: a 10% increase in 1-naphthol was associated with a 1.6% increase in breast milk naphthalene (95% CI: 0.2%-3.1%). No significant associations were observed between naphthalene sources reported in self-administered questionnaires and the air or biomarker concentrations. Conclusions Median urinary concentrations of naphthalene metabolites tended to be similar to (1-naphthol) or lower (2-naphthol) than those reported in a Canadian survey of women of reproductive age. Only urinary 1-naphthol and naphthalene in breast milk were associated. Potential reasons for the lack of other associations include a lack of sources, varying biotransformation rates and behavioural differences over time. PMID:24767676

  19. Personal exposure to airborne particles and metals: results from the Particle TEAM study in Riverside, California.

    PubMed

    Ozkaynak, H; Xue, J; Spengler, J; Wallace, L; Pellizzari, E; Jenkins, P

    1996-01-01

    The PTEAM Study was the first large-scale probability-based study of personal exposure to particles. Sponsored by the U.S. Environmental Protection Agency (EPA) and the Air Resources Board of California, it was carried out by the Research Triangle Institute (RTI) and the Harvard University School of Public Health (HSPH). HSPH designed and constructed a 4-lpm, battery-operated personal monitor for inhalable particles (PM10) that could be worn comfortably for up to 14 hours by persons from 10 to 70 years old. The monitor was worn for two consecutive 12-hour periods (day and night) during the fall of 1990 by 178 participants representing 139,000 nonsmoking residents of Riverside, California. Nearly identical monitors were employed to collect concurrent indoor and outdoor samples. The monitors were equipped with a different sampling nozzle to collect fine particles (PM2.5). Population-weighted daytime personal PM10 exposures averaged 150 +/- 9 (SE) micrograms/m3, compared to concurrent indoor and outdoor concentrations of 95 +/- 6 micrograms/m3. This suggested the existence of excess mass near the person, a "personal cloud" that appeared related to personal activities. Fourteen of 15 prevalent elements also were evaluated in the personal samples. The two major indoor sources of indoor particles were smoking and cooking; even in these homes, however, more than half of the indoor particles came from outdoors, and a substantial portion of the indoor particles were of undetermined indoor origin. Outdoor concentrations near the homes were well correlated with outdoor concentrations at the central site, supporting the idea of using the central site as an indicator of of ambient concentrations over a wider area. Indoor concentrations were only weakly correlated with outdoor concentrations, however, and personal exposures were even more poorly correlated with outdoor concentrations. Elemental profiles were obtained for environmental tobacco smoke (ETS) (major contributions from potassium and chlorine) and cooking emissions (aluminum, iron, calcium, and chlorine). These profiles can be used in future source apportionment studies.

  20. Indoor air quality in green buildings: A case-study in a residential high-rise building in the northeastern United States.

    PubMed

    Xiong, Youyou; Krogmann, Uta; Mainelis, Gediminas; Rodenburg, Lisa A; Andrews, Clinton J

    2015-01-01

    Improved indoor air quality (IAQ) is one of the critical components of green building design. Green building tax credit (e.g., New York State Green Building Tax Credit (GBTC)) and certification programs (e.g., Leadership in Energy & Environmental Design (LEED)) require indoor air quality measures and compliance with allowable maximum concentrations of common indoor air pollutants. It is not yet entirely clear whether compliance with these programs results in improved IAQ and ultimately human health. As a case in point, annual indoor air quality measurements were conducted in a residential green high-rise building for five consecutive years by an industrial hygiene contractor to comply with the building's GBTC requirements. The implementation of green design measures resulted in better IAQ compared to data in references of conventional homes for some parameters, but could not be confirmed for others. Relative humidity and carbon dioxide were satisfactory according to existing standards. Formaldehyde levels during four out of five years were below the most recent proposed exposure limits found in the literature. To some degree, particulate matter (PM) levels were lower than that in studies from conventional residential buildings. Concentrations of Volatile Organic Compounds (VOCs) with known permissible exposure limits were below levels known to cause chronic health effects, but their concentrations were inconclusive regarding cancer health effects due to relatively high detection limits. Although measured indoor air parameters met all IAQ maximum allowable concentrations in GBTC and applicable LEED requirements at the time of sampling, we argue that these measurements were not sufficient to assess IAQ comprehensively because more sensitive sampling/analytical methods for PM and VOCs are needed; in addition, there is a need for a formal process to ensure rigor and adequacy of sampling and analysis methods. Also, we suggest that a comprehensive IAQ assessment should include mixed mode thermal comfort models, semi-volatile organic compounds, assessment of new chemicals, and permissible exposure levels of many known indoor VOCs and bioaerosols. Plus, the relationship between energy consumption and IAQ, and tenant education on health effects of indoor pollutants and their sources may need more attention in IAQ investigations in green buildings.

  1. From the Ground Up: Floorcovering Recommendations from an IAQ Consortium. Issuetrak: A CEFPI Brief on Educational Facility Issues.

    ERIC Educational Resources Information Center

    Frank, David

    This brief describes the findings of a consortium on indoor air quality (IAQ) in educational facilities held in Chattanooga, Tennessee. The objective was to determine the impact floorcoverings have on indoor air quality in schools relative to maintenance, volatile organic compounds (VOCs), airborne contaminants, moisture, surface contaminants, and…

  2. Differential effects of air conditioning type on residential endotoxin levels in a semi-arid climate.

    PubMed

    Johnston, J D; Kruman, B A; Nelson, M C; Merrill, R M; Graul, R J; Hoybjerg, T G; Tuttle, S C; Myers, S J; Cook, R B; Weber, K S

    2017-09-01

    Residential endotoxin exposure is associated with protective and pathogenic health outcomes. Evaporative coolers, an energy-efficient type of air conditioner used in dry climates, are a potential source of indoor endotoxins; however, this association is largely unstudied. We collected settled dust biannually from four locations in homes with evaporative coolers (n=18) and central air conditioners (n=22) in Utah County, Utah (USA), during winter (Jan-Apr) and summer (Aug-Sept), 2014. Dust samples (n=281) were analyzed by the Limulus amebocyte lysate test. Housing factors were measured by survey, and indoor temperature and relative humidity measures were collected during both seasons. Endotoxin concentrations (EU/mg) were significantly higher in homes with evaporative coolers from mattress and bedroom floor samples during both seasons. Endotoxin surface loads (EU/m 2 ) were significantly higher in homes with evaporative coolers from mattress and bedroom floor samples during both seasons and in upholstered furniture during winter. For the nine significant season-by-location comparisons, EU/mg and EU/m 2 were approximately three to six times greater in homes using evaporative coolers. A plausible explanation for these findings is that evaporative coolers serve as a reservoir and distribution system for Gram-negative bacteria or their cell wall components in homes. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Indoor air bacterial load and antibiotic susceptibility pattern of isolates in operating rooms and surgical wards at jimma university specialized hospital, southwest ethiopia.

    PubMed

    Genet, Chalachew; Kibru, Gebre; Tsegaye, Wondewosen

    2011-03-01

    Surgical site infection is the second most common health care associated infection. One of the risk factors for such infection is bacterial contamination of operating rooms' and surgical wards' indoor air. In view of that, the microbiological quality of air can be considered as a mirror of the hygienic condition of these rooms. Thus, the objective of this study was to determine the bacterial load and antibiotic susceptibility pattern of isolates in operating rooms' and surgical wards' indoor air of Jimma University Specialized Hospital. A cross sectional study was conducted to measure indoor air microbial quality of operating rooms and surgical wards from October to January 2009/2010 on 108 indoor air samples collected in twelve rounds using purposive sampling technique by Settle Plate Method (Passive Air Sampling following 1/1/1 Schedule). Sample processing and antimicrobial susceptibility testing were done following standard bacteriological techniques. The data was analyzed using SPSS version 16 and interpreted according to scientifically determined baseline values initially suggested by Fisher. The mean aerobic colony counts obtained in OR-1(46cfu/hr) and OR-2(28cfu/hr) was far beyond the set 5-8cfu/hr acceptable standards for passive room. Similarly the highest mean aerobic colony counts of 465cfu/hr and 461cfu/hr were observed in Female room-1 and room-2 respectively when compared to the acceptable range of 250-450cfu/hr. In this study only 3 isolates of S. pyogenes and 48 isolates of S. aureus were identified. Over 66% of S. aureus was identified in Critical Zone of Operating rooms. All isolates of S. aureus showed 100% and 82.8% resistance to methicillin and ampicillin respectively. Higher degree of aerobic bacterial load was measured from operating rooms' and surgical wards' indoor air. Reducing foot trafficking, improving the ventilation system and routine cleaning has to be made to maintain the aerobic bacteria load with in optimal level.

  4. Indoor Exposure Product Testing Protocols Version 2

    EPA Science Inventory

    EPA’s Office of Pollution Prevention and Toxics (OPPT) has developed a set of ten indoor exposure testing protocols intended to provide information on the purpose of the testing, general description of the sampling and analytical procedures, and references for tests that will be ...

  5. MEASUREMENT OF INDOOR RADON-THORON IN AIR AND EXHALATION FROM SOIL IN THE ENVIRONMENT OF WESTERN HARYANA, INDIA.

    PubMed

    Mann, Nisha; Kumar, Amit; Kumar, Sushil; Chauhan, R P

    2016-10-01

    Measurement of indoor radon and thoron is important because the inhalation of radon-thoron and their daughters contributes more than 50 % of the total dose from natural sources. One of the important parameters to find out the contribution of soil and building materials towards indoor radon is radon exhalation rates, which can be used for estimation of indoor radon levels. The indoor radon and thoron levels from the air and radon exhalation rates from soil samples collected from two districts (Hisar and Fatehabad) of Western Haryana are measured using pin-hole-based radon-thoron dosimeter and LR-115 solid-state nuclear track detector by canister technique. The results show that the indoor radon and thoron levels from Hisar district varied from 11 to 112 and 11 to 80 Bq m -3 , while for Fatehabad district from 5 to 24 and 59 to 105 Bq m -3 , respectively, in summer season. In winter season, indoor radon and thoron levels from Hisar district varied from 15 to 43 and 32 to 102 Bq m -3 , while for Fatehabad district from 18 to 31 and 11 to 80 Bq m -3 , respectively. The indoor radon levels of 95 % locations lie well below the limit recommended by International Commission of Radiation Protection, 2011. The radon mass exhalation rate varied from 6 to 56 mBq kg -1 h -1 The radon mass exhalation rates from the soil samples were lower than the worldwide average, i.e. 56 mBq kg -1 h -1 There exists a poor correlation between indoor radon and exhalation rates. More investigations of measurement of radionuclide contents from rock and stone of study area can improve the understanding. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. ASSESSMENT OF THE INDOOR ENVIRONMENT AND IMPLICATIONS FOR HEALTH IN ROMA VILLAGES IN SLOVAKIA AND ROMANIA

    PubMed Central

    Majdan, Marek; Coman, Alexandru; Gallová, Eva; Ďuricová, Janka; Kállayová, Daniela; Kvaková, Mária; Bošák, Ľuboš

    2013-01-01

    SUMMARY Objectives The objective of this paper is to provide information on indoor air quality and on the quality of the broader indoor environment of the houses in Roma villages in Slovakia and Romania and to discuss possible implications for health. Methods Indoor air was sampled in 11 houses in a Romanian Roma village and in 19 houses in a Slovakian Roma village. Levels of Carbon Monoxide (CO), Carbon Dioxide (CO2), total particulate matter (PM), temperature and humidity were measured. A questionnaire and a checklist were used to obtain additional information on the indoor environment and behavioural factors. We have sampled the same houses in winter and in summer. Results Levels of CO and CO2 were higher in winter in both countries as compared to summer. The limit value of 10 mg/m3 CO was exceeded in a few cases in both countries. In general, levels of CO, CO2 and PM were higher in Romania. Further environmental and behavioural hazards such as indoor smoking, pets inside or lack of ventilation were found. The reported self-perceived quality of the indoor environment was poor in many aspects. Conclusions Our findings of CO, CO2 and PM levels suggest that indoor air pollution in Roma settlements has the potential to be a health threat. The fact that the inhabitants spend a relatively long time inside the houses and that a number of additional environmental and behavioural hazards were identified by our study emphasizes the importance of the indoor air quality for health and thus priority attention should be paid to these issues by health authorities and researchers. Further research is essential and study designs must consider cultural background and specific characteristics of the community, especially in order to obtain valid data on health outcomes. PMID:23285520

  7. Predicting residential indoor concentrations of nitrogen dioxide, fine particulate matter, and elemental carbon using questionnaire and geographic information system based data

    NASA Astrophysics Data System (ADS)

    Baxter, Lisa K.; Clougherty, Jane E.; Paciorek, Christopher J.; Wright, Rosalind J.; Levy, Jonathan I.

    Previous studies have identified associations between traffic-related air pollution and adverse health effects. Most have used measurements from a few central ambient monitors and/or some measure of traffic as indicators of exposure, disregarding spatial variability and factors influencing personal exposure-ambient concentration relationships. This study seeks to utilize publicly available data (i.e., central site monitors, geographic information system, and property assessment data) and questionnaire responses to predict residential indoor concentrations of traffic-related air pollutants for lower socioeconomic status (SES) urban households. As part of a prospective birth cohort study in urban Boston, we collected indoor and outdoor 3-4 day samples of nitrogen dioxide (NO 2) and fine particulate matter (PM 2.5) in 43 low SES residences across multiple seasons from 2003 to 2005. Elemental carbon (EC) concentrations were determined via reflectance analysis. Multiple traffic indicators were derived using Massachusetts Highway Department data and traffic counts collected outside sampling homes. Home characteristics and occupant behaviors were collected via a standardized questionnaire. Additional housing information was collected through property tax records, and ambient concentrations were collected from a centrally located ambient monitor. The contributions of ambient concentrations, local traffic and indoor sources to indoor concentrations were quantified with regression analyses. PM 2.5 was influenced less by local traffic but had significant indoor sources, while EC was associated with traffic and NO 2 with both traffic and indoor sources. Comparing models based on covariate selection using p-values or a Bayesian approach yielded similar results, with traffic density within a 50 m buffer of a home and distance from a truck route as important contributors to indoor levels of NO 2 and EC, respectively. The Bayesian approach also highlighted the uncertanity in the models. We conclude that by utilizing public databases and focused questionnaire data we can identify important predictors of indoor concentrations for multiple air pollutants in a high-risk population.

  8. A novel experimental technology for testing efficacy of air purifiers on pollen reduction.

    PubMed

    Bergmann, Karl-Christian; Sehlinger, Torsten; Gildemeister, Julia; Zuberbier, Torsten

    2017-01-01

    Allergenic pollen exposure is mostly seen as an outdoor phenomenon but studies have shown an indoor exposure: different pollen species including birch and grass pollen in houses, schools, and shops are leading to long-lasting symptoms even after the pollen season because pollen settle on surfaces and re-enter the indoor air depending on ventilation. To reduce indoor pollen load, windows need to be closed and devices should be used: as pure wiping and cleaning of surfaces is mostly not sufficient, air cleaners may be helpful in reducing pollen counts in indoor environment. The efficacy of an air cleaner is usually described by the filtration rate of standard dust particle sizes which is not necessarily related to clinical efficacy. A novel study design was developed using the technical equipment of a new mobile exposure chamber to investigate participants with allergic rhinitis (individual observational, controlled, prospective, single arm study). The tested air cleaner reduced the grass pollen-induced (4000 grass pollen/m 3 over 90 min) nasal symptoms (total nasal symptom score) significantly from 6 and 4 points (1st and 2nd exposure in sham run) to less than 1 point when air cleaner was activated. The novel study protocol is suitable for testing efficacy of air cleaners and the tested air cleaner is effective in reducing clinical symptoms due to grass pollen in an indoor environment.

  9. PESTICIDE RESIDUE RECOVERIES FROM SURFACE WIPES

    EPA Science Inventory

    Human exposure is a consequence of pesticide use indoors with a primary source resulting from residue deposition on household surfaces. Accurate measurements of surface residues is essential for estimating exposure from different routes. Various procedures have been developed ...

  10. Determining Source Strength of Semivolatile Organic Compounds using Measured Concentrations in Indoor Dust

    PubMed Central

    Shin, Hyeong-Moo; McKone, Thomas E.; Nishioka, Marcia G.; Fallin, M. Daniele; Croen, Lisa A.; Hertz-Picciotto, Irva; Newschaffer, Craig J.; Bennett, Deborah H.

    2014-01-01

    Consumer products and building materials emit a number of semivolatile organic compounds (SVOCs) in the indoor environment. Because indoor SVOCs accumulate in dust, we explore the use of dust to determine source strength and report here on analysis of dust samples collected in 30 U.S. homes for six phthalates, four personal care product ingredients, and five flame retardants. We then use a fugacity-based indoor mass-balance model to estimate the whole house emission rates of SVOCs that would account for the measured dust concentrations. Di-2-ethylhexyl phthalate (DEHP) and di-iso-nonyl phthalate (DiNP) were the most abundant compounds in these dust samples. On the other hand, the estimated emission rate of diethyl phthalate (DEP) is the largest among phthalates, although its dust concentration is over two orders of magnitude smaller than DEHP and DiNP. The magnitude of the estimated emission rate that corresponds to the measured dust concentration is found to be inversely correlated with the vapor pressure of the compound, indicating that dust concentrations alone cannot be used to determine which compounds have the greatest emission rates. The combined dust-assay modeling approach shows promise for estimating indoor emission rates for SVOCs. PMID:24118221

  11. Neural computing thermal comfort index PMV for the indoor environment intelligent control system

    NASA Astrophysics Data System (ADS)

    Liu, Chang; Chen, Yifei

    2013-03-01

    Providing indoor thermal comfort and saving energy are two main goals of indoor environmental control system. An intelligent comfort control system by combining the intelligent control and minimum power control strategies for the indoor environment is presented in this paper. In the system, for realizing the comfort control, the predicted mean vote (PMV) is designed as the control goal, and with chastening formulas of PMV, it is controlled to optimize for improving indoor comfort lever by considering six comfort related variables. On the other hand, a RBF neural network based on genetic algorithm is designed to calculate PMV for better performance and overcoming the nonlinear feature of the PMV calculation better. The formulas given in the paper are presented for calculating the expected output values basing on the input samples, and the RBF network model is trained depending on input samples and the expected output values. The simulation result is proved that the design of the intelligent calculation method is valid. Moreover, this method has a lot of advancements such as high precision, fast dynamic response and good system performance are reached, it can be used in practice with requested calculating error.

  12. Mono-, di-, and trichlorinated biphenyls (PCB 1-PCB 39) in the indoor air of office rooms and their relevance on human blood burden.

    PubMed

    Kraft, M; Sievering, S; Grün, L; Rauchfuss, K

    2018-05-01

    Exposure to polychlorinated biphenyls (PCBs) from indoor air can lead to a significant increase in lower chlorinated congeners in human blood. Lower chlorinated congeners with short biological half-lives can exhibit an indirect genotoxic potential via their highly reactive metabolites. However, little is known about their occurrence in indoor air and, therefore, about the effects of possible exposure to these congeners. We analyzed all mono-, di-, and trichlorinated biphenyls in the indoor air of 35 contaminated offices, as well as in the blood of the 35 individuals worked in these offices for a minimum of 2 years. The median concentration of total PCB in the indoor air was 479 ng/m 3 . The most prevalent PCBs in the indoor air samples were the trichlorinated congeners PCB 31, PCB 18, and PCB 28, with median levels of 39, 31, and 26 ng/m 3 , respectively. PCB 8 was the most prevalent dichlorinated congener (median: 9.1 ng/m 3 ). Monochlorinated biphenyls were not detected in relevant concentrations. In the blood samples, the most abundant congener was PCB 28; nearly 90% of all mono-, di-, and trichlorinated congeners were attributed to this congener (median: 12 ng/g blood lipid). © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Humans differ in their personal microbial cloud

    PubMed Central

    Altrichter, Adam E.; Bateman, Ashley C.; Stenson, Jason; Brown, GZ; Green, Jessica L.; Bohannan, Brendan J.M.

    2015-01-01

    Dispersal of microbes between humans and the built environment can occur through direct contact with surfaces or through airborne release; the latter mechanism remains poorly understood. Humans emit upwards of 106 biological particles per hour, and have long been known to transmit pathogens to other individuals and to indoor surfaces. However it has not previously been demonstrated that humans emit a detectible microbial cloud into surrounding indoor air, nor whether such clouds are sufficiently differentiated to allow the identification of individual occupants. We used high-throughput sequencing of 16S rRNA genes to characterize the airborne bacterial contribution of a single person sitting in a sanitized custom experimental climate chamber. We compared that to air sampled in an adjacent, identical, unoccupied chamber, as well as to supply and exhaust air sources. Additionally, we assessed microbial communities in settled particles surrounding each occupant, to investigate the potential long-term fate of airborne microbial emissions. Most occupants could be clearly detected by their airborne bacterial emissions, as well as their contribution to settled particles, within 1.5–4 h. Bacterial clouds from the occupants were statistically distinct, allowing the identification of some individual occupants. Our results confirm that an occupied space is microbially distinct from an unoccupied one, and demonstrate for the first time that individuals release their own personalized microbial cloud. PMID:26417541

  14. The effect of an ion generator on indoor air quality in a residential room.

    PubMed

    Waring, M S; Siegel, J A

    2011-08-01

    Ion generators charge particles with a corona prior to their removal on collector plates or indoor surfaces and also emit ozone, which can react with terpenes to yield secondary organic aerosol, carbonyls, carboxylic acids, and free radicals. This study characterized the indoor air quality implications of operating an ion generator in a 27 m(3) residential room, with four different test room configurations. Two room configurations had carpet overlaying the original flooring of stained/sealed concrete, and for one configuration with and without carpet, a plug-in air freshener was used as a terpene source. Measurements included airborne sampling of particulate matter (0.015-20 μm), terpenes and C(1) -C(4) and C(6) -C(10) aldehydes, ozone concentrations, and air exchange rates. When the heating, ventilating, and air-conditioning system was not operating (room air exchange rate = ∼0.5/h), the use of the ion generator in the presence of the air freshener led to a net increase in ultrafine particles (<0.1 μm). Also, increased concentrations of ozone were observed regardless of air freshener presence, as well as increases in formaldehyde and nonanal, albeit within measurement uncertainty in some cases. Thus, it may be prudent to limit ion generator use indoors until evidence of safety can be ascertained. Portable ion generators are intended to clean the air of particles, but they may emit ozone as a byproduct of their operation, which has the potential to degrade indoor air quality. This study showed that under certain conditions in a residential room, the use of a portable ion generator can increase concentrations of ozone and, to a lesser degree, potentially aldehydes. Also, if operated in the presence of a plug-in air freshener that emits terpenes, its use can increase concentrations of secondary organic aerosol in the ultrafine size range. © 2010 John Wiley & Sons A/S.

  15. Wind-induced contaminant transport in near-surface soils with application to radon entry into buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riley, William Jowett

    1996-05-01

    Indoor air exposures to gaseous contaminants originating in soil can cause large human health risks. To predict and control these exposures, the mechanisms that affect vapor transport in near-surface soils need to be understood. In particular, radon exposure is a concern since average indoor radon concentrations lead to much higher risks than are generally accepted for exposure to other environmental contaminants. This dissertation examines an important component of the indoor radon problem: the impacts of wind on soil-gas and radon transport and entry into buildings. The research includes experimental and modeling studies of wind`s interactions with a building`s superstructure andmore » the resulting soil-gas and radon flows in the surrounding soil. In addition to exploring the effects of steady winds, a novel modeling technique is developed to examine the impacts of fluctuating winds on soil-gas and radon transport.« less

  16. Characterization of indoor air quality and resident health in an Arizona senior housing apartment building.

    PubMed

    Frey, Sarah E; Destaillats, Hugo; Cohn, Sebastian; Ahrentzen, Sherry; Fraser, Matthew P

    2014-11-01

    A survey of key indoor air quality (IAQ) parameters and resident health was carried out in 72 apartments within a single low-income senior housing building in Phoenix, Arizona. Air sampling was carried out simultaneously with a questionnaire on personal habits and general health of residents. Mean PM10 concentrations are 66 +/- 16, 58 +/- 13, and 24 +/- 3 microg/m3 and mean PM2.5 concentrations are 62 +/- 16, 53 +/- 13, and 20 +/- 2 microg/m3 for the living room, kitchen, and outdoor balcony, respectively. Median PM10 concentrations are 17, 18 and 17 microg/m3 and median PM25 concentrations are 13, 14, and 13 microg/m3, respectively. The initial results indicate that increased indoor particle concentrations coincide with residents who report smoking cigarettes. Indoor formaldehyde concentrations revealed median levels of 36.9, 38.8, and 4.3 ppb in the living room, kitchen, and balcony, respectively. Results show that 36% of living room samples and 44% of kitchen samples exceeded the Health Canada REL for chronic exposure to formaldehyde (40 ppb). Associations between occupants' behavior self-reported health conditions, and IAQ are evaluated.

  17. A positive chemical ionization GC/MS method for the determination of airborne ethylene glycol and propylene glycols in non-occupational environments.

    PubMed

    Zhu, Jiping; Feng, Yong-Lai; Aikawa, Bio

    2004-11-01

    An analytical method for ethylene glycol and propylene glycols has been developed for measuring airborne levels of these chemicals in non-occupational environments such as residences and office buildings. The analytes were collected on charcoal tubes, solvent extracted, and analyzed by gas chromatography-mass spectrometry using a positive chemical ionization technique. The method had a method detection limit of 0.07 microg m(-3) for ethylene glycol and 0.03 microg m(-3) for 1,2- and 1,3-propylene glycols, respectively, based on a 1.44 m3 sampling volume. Indoor air samples of several residential homes and other indoor environments have been analyzed. The median concentrations of ethylene glycol and 1,2-propylene glycol in nine residential indoor air samples were 53 microg m(-3) and 13 microg m(-3) respectively with maximum values of 223 microg m(-3) and 25 microg m(-3) detected for ethylene glycol and 1,2-propylene glycol respectively. The concentrations of these two chemicals in one office and two laboratories were at low microg m(-3) levels. The maximum concentration of 1,3-propylene glycol detected in indoor air was 0.1 microg m(-3).

  18. A Web-Based Intervention to Reduce Indoor Tanning Motivations In Adolescents: A Randomized Controlled Trial

    PubMed Central

    Hillhouse, Joel; Turrisi, Rob; Scaglione, Nichole M.; Cleveland, Michael J.; Baker, Katie; Florence, L. Carter

    2016-01-01

    Youthful indoor tanning as few as ten sessions can increase the risk of melanoma by 2 to 4 times with each additional session adding another 2% to the risk. Recent research estimates that indoor tanning can be linked to approximately 450,000 cases of skin cancer annually in the United States, Europe, and Australia. Despite these risks, indoor tanning remains popular with adolescents. This study tested the efficacy of a web-based skin cancer prevention intervention designed to reduce indoor tanning motivations in adolescent females. A nationally representative sample of 443 female teens were enrolled from an online panel into a two-arm, parallel group design, randomized controlled trial. Treatment participants received an appearance-focused intervention grounded in established health behavior change models. Controls viewed a teen alcohol prevention website. Outcome variables included willingness and intentions to indoor tan, willingness to sunless tan and measures of indoor tanning attitudes and beliefs. The intervention decreased willingness and intentions to indoor tan and increased sunless tanning willingness relative to controls. We also examined indirect mechanisms of change through intervening variables (e.g., indoor tanning attitudes, norms, positive and negative expectancies) using the product of coefficients approach. The web-based intervention demonstrated efficacy in changing adolescent indoor tanning motivations and improving their orientation toward healthier alternatives. Results from the intervening variable analyses give guidance to future adolescent skin cancer prevention interventions. PMID:27549602

  19. A Web-Based Intervention to Reduce Indoor Tanning Motivations in Adolescents: a Randomized Controlled Trial.

    PubMed

    Hillhouse, Joel; Turrisi, Rob; Scaglione, Nichole M; Cleveland, Michael J; Baker, Katie; Florence, L Carter

    2017-02-01

    Youthful indoor tanning as few as ten sessions can increase the risk of melanoma by two to four times with each additional session adding another 2 % to the risk. Recent research estimates that indoor tanning can be linked to approximately 450,000 cases of skin cancer annually in the USA, Europe, and Australia. Despite these risks, indoor tanning remains popular with adolescents. This study tested the efficacy of a web-based skin cancer prevention intervention designed to reduce indoor tanning motivations in adolescent females. A nationally representative sample of 443 female teens was enrolled from an online panel into a two-arm, parallel group design, randomized controlled trial. Treatment participants received an appearance-focused intervention grounded in established health behavior change models. Controls viewed a teen alcohol prevention website. Outcome variables included willingness and intentions to indoor tan, willingness to sunless tan, and measures of indoor tanning attitudes and beliefs. The intervention decreased willingness and intentions to indoor tan and increased sunless tanning willingness relative to controls. We also examined indirect mechanisms of change through intervening variables (e.g., indoor tanning attitudes, norms, positive and negative expectancies) using the product of coefficient approach. The web-based intervention demonstrated efficacy in changing adolescent indoor tanning motivations and improving their orientation toward healthier alternatives. Results from the intervening variable analyses give guidance to future adolescent skin cancer prevention interventions.

  20. Determinants of indoor benzene in Europe

    NASA Astrophysics Data System (ADS)

    Lai, H. K.; Jantunen, M. J.; Künzli, N.; Kulinskaya, E.; Colvile, R.; Nieuwenhuijsen, M. J.

    This study identified the key determinants associated with the indoor benzene concentrations that were measured between 1996 and 2000 using the EXPOLIS protocol in the residences of six European cities, including Athens (Greece), Basel (Switzerland), Helsinki (Finland), Milan (Italy), Oxford (United Kingdom), and Prague (Czech Republic). Two consecutive days of home indoor and home outdoor measurements of benzene were carried out at the homes of adult participants on different dates and seasons during the sampling period. Regression models, with interactions searched by all-possible subset method, were used to assess the city effects and the determinants of home indoor benzene (adjusted R2=0.57, n=412). Outdoor benzene concentrations, outdoor temperature, wind speed, the use of anti-moth products, and indoor smoking in terms of number of cigarettes consumed per day were shown to be the key determinants of indoor benzene concentrations. The model was further used to predict the indoor benzene levels in cities. Non-linear relationships were commonly found, indicating that a unit change in the indoor concentration cannot be simply estimated by a proportional change of the determinant, and the pattern of relationships could be differed in different places. This finding is important in formulating indoor air quality guidelines as well as calculating an accurate health risk estimate based on the estimates of population's lifetime exposure levels.

  1. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR USE OF AN ACTIVE SAMPLING DEVICE FOR THE COLLECTION OF AIRBORNE VOCS AT FIXED INDOOR AND OUTDOOR SITES (UA-F-11.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used to collect indoor and outdoor air samples for the determination of selected volatile organic compounds (VOC's) using a pump to draw air through a Carbotrap Sampler. Volatile organic compounds (VOCs) present in the air are p...

  2. Use of Compound-Specific Stable Isotope Analysis to Distinguish Between Vapor Intrusion and Indoor Sources of VOCs - CSIA Protocol for Vapor Intrusion Investigations

    DTIC Science & Technology

    2014-07-01

    Analyzer TCE Trichloroethene USEPA U.S. Environmental Protection Agency V- PDB Vienna - Pee Dee Belemnite V-SMOW Vienna – Standard Mean Ocean Water ... PDB ) for carbon, Standard Mean Ocean Chloride (SMOC) for chlorine, and Vienna-Standard Mean Ocean Water (V-SMOW) for hydrogen. CSIA Protocol for...7 3.3 INDOOR AIR SAMPLING LOCATIONS ............................................................ 8 3.4 COLLECTION OF WATER SAMPLES

  3. An assessment of indoor air quality in recent Mexican immigrant housing in Commerce City, Colorado

    NASA Astrophysics Data System (ADS)

    Miller, Shelly L.; Scaramella, Peter; Campe, Joseph; Goss, Cynthia W.; Diaz-Castillo, Sandra; Hendrikson, Ed; DiGuiseppi, Carolyn; Litt, Jill

    An indoor air quality assessment was conducted on 100 homes of recent Mexican immigrants in Commerce City, Colorado, an urban industrial community north of Denver. Head of households were administered a family health survey, filled out an activity diary, and participated in a home inspection. Carbon monoxide (CO) and carbon dioxide (CO 2) were measured for 24 h inside the main living area and outside of the homes. Harvard Impactors were used to collect 24-h samples of PM 2.5 at the same locations for gravimetric analysis. Dust samples were collected by vacuuming carpeting and flooring at four locations within the home and analyzed by ELISA for seven allergens. Mean indoor and outdoor PM 2.5 levels were 27.2 and 8.5 μg m -3, respectively. Indoor PM 2.5 and CO 2 were elevated in homes for which the number of hours with door/window open was zero compared to homes in which the number of hours was high (>15 h). Indoor PM 2.5 levels did not correlate with outdoor levels and tended to increase with number of inhabitants, and results indicate that the source of indoor particles were occupants and their activities, excluding smoking and cooking. Mean indoor CO 2 and CO levels were 1170 and 2.4 ppm, respectively. Carbon monoxide was higher than the 24-h National Ambient Air Quality Standard in 3 of the homes. The predominant allergens were cat ( Fel d 1) and mouse ( Mus m 1) allergens, found in 20 and 34 homes, respectively.

  4. Indoor/outdoor relationships of PM10, PM2.5, and PM1 mass concentrations and their water-soluble ions in a retirement home and a school dormitory

    NASA Astrophysics Data System (ADS)

    Hassanvand, Mohammad Sadegh; Naddafi, Kazem; Faridi, Sasan; Arhami, Mohammad; Nabizadeh, Ramin; Sowlat, Mohammad Hossein; Pourpak, Zahra; Rastkari, Noushin; Momeniha, Fatemeh; Kashani, Homa; Gholampour, Akbar; Nazmara, Shahrokh; Alimohammadi, Mahmood; Goudarzi, Gholamreza; Yunesian, Masud

    2014-01-01

    Indoor/outdoor particulate matter (PM10, PM2.5, and PM1) and their water-soluble ions were measured in a retirement home and a school dormitory in Tehran, from May 2012 to January 2013. Hourly indoor/outdoor PM concentrations were measured using GRIMM dust monitors and 24-h aerosol samples were collected by low-volume air samplers. Water-soluble ions were determined using an ion chromatography (IC) instrument. Although the mean outdoor PM concentrations in both sampling sites were almost equal, the mean indoor PM10 in the school dormitory was approximately 1.35 times higher than that in the retirement home. During a Middle Eastern dust storm, the 24-h average PM10, PM2.5, and PM1 concentrations were respectively 3.4, 2.9, and 1.9 times as high as those in normal days outdoors and 3.4, 2.8, and 1.6 times indoors. The results indicated that secondary inorganic aerosols were the dominant water-soluble ions of indoor and outdoor PM. We found that the smaller the particle, the higher the percentage of secondary inorganic aerosols. Except for PM10 in the school dormitory, strong correlations were found between indoor and outdoor PM. We estimated that nearly 45% of PM10, 67% of PM2.5, and 79% of PM1 in the retirement home, and 32% of PM10, 76% of PM2.5, and 83% of PM1 in the school dormitory originated from outdoor environment.

  5. Toward quantifying the abuse liability of ultraviolet tanning: A behavioral economic approach to tanning addiction.

    PubMed

    Reed, Derek D; Kaplan, Brent A; Becirevic, Amel; Roma, Peter G; Hursh, Steven R

    2016-07-01

    Many adults engage in ultraviolet indoor tanning despite evidence of its association with skin cancer. The constellation of behaviors associated with ultraviolet indoor tanning is analogous to that in other behavioral addictions. Despite a growing literature on ultraviolet indoor tanning as an addiction, there remains no consensus on how to identify ultraviolet indoor tanning addictive tendencies. The purpose of the present study was to translate a behavioral economic task more commonly used in substance abuse to quantify the "abuse liability" of ultraviolet indoor tanning, establish construct validity, and determine convergent validity with the most commonly used diagnostic tools for ultraviolet indoor tanning addiction (i.e., mCAGE and mDSM-IV-TR). We conducted a between-groups study using a novel hypothetical Tanning Purchase Task to quantify intensity and elasticity of ultraviolet indoor tanning demand and permit statistical comparisons with the mCAGE and mDSM-IV-TR. Results suggest that behavioral economic demand is related to ultraviolet indoor tanning addiction status and adequately discriminates between potential addicted individuals from nonaddicted individuals. Moreover, we provide evidence that the Tanning Purchase Task renders behavioral economic indicators that are relevant to public health research. The present findings are limited to two ultraviolet indoor tanning addiction tools and a relatively small sample of high-risk ultraviolet indoor tanning users; however, these pilot data demonstrate the potential for behavioral economic assessment tools as diagnostic and research aids in ultraviolet indoor tanning addiction studies. © 2016 Society for the Experimental Analysis of Behavior.

  6. POST-APPLICATION EXPOSURE POTENTIAL TO PESTICIDES IN THE RESIDENTIAL ENVIRONMENT

    EPA Science Inventory

    A study to investigate the temporal and spatial distributions of pesticides applied by homeowners and commercial applicators for indoor crack and crevice treatments was initiated by the U.S. EPA in 1999. In participating households, pre- and post-application samples of indoor ...

  7. An evaluation of indoor and outdoor biological particulate matter (BioPM)

    EPA Science Inventory

    Monitoring of indoor and ambient particulate matter (PM) and the characterization of the content for biological aerosol concentrations has not been extensively performed. Samples from urban and rural North Carolina, and Denver, CO, were collected and analyzed as the goal of this ...

  8. Ozone-surface interactions: Investigations of mechanisms, kinetics, mass transport, and implications for indoor air quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morrison, Glenn Charles

    1999-12-01

    In this dissertation, results are presented of laboratory investigations and mathematical modeling efforts designed to better understand the interactions of ozone with surfaces. In the laboratory, carpet and duct materials were exposed to ozone and measured ozone uptake kinetics and the ozone induced emissions of volatile organic compounds. To understand the results of the experiments, mathematical methods were developed to describe dynamic indoor aldehyde concentrations, mass transport of reactive species to smooth surfaces, the equivalent reaction probability of whole carpet due to the surface reactivity of fibers and carpet backing, and ozone aging of surfaces. Carpets, separated carpet fibers, andmore » separated carpet backing all tended to release aldehydes when exposed to ozone. Secondary emissions were mostly n-nonanal and several other smaller aldehydes. The pattern of emissions suggested that vegetable oils may be precursors for these oxidized emissions. Several possible precursors and experiments in which linseed and tung oils were tested for their secondary emission potential were discussed. Dynamic emission rates of 2-nonenal from a residential carpet may indicate that intermediate species in the oxidation of conjugated olefins can significantly delay aldehyde emissions and act as reservoir for these compounds. The ozone induced emission rate of 2-nonenal, a very odorous compound, can result in odorous indoor concentrations for several years. Surface ozone reactivity is a key parameter in determining the flux of ozone to a surface, is parameterized by the reaction probability, which is simply the probability that an ozone molecule will be irreversibly consumed when it strikes a surface. In laboratory studies of two residential and two commercial carpets, the ozone reaction probability for carpet fibers, carpet backing and the equivalent reaction probability for whole carpet were determined. Typically reaction probability values for these materials were 10 -7, 10 -5, and 10 -5 respectively. To understand how internal surface area influences the equivalent reaction probability of whole carpet, a model of ozone diffusion into and reaction with internal carpet components was developed. This was then used to predict apparent reaction probabilities for carpet. He combines this with a modified model of turbulent mass transfer developed by Liu, et al. to predict deposition rates and indoor ozone concentrations. The model predicts that carpet should have an equivalent reaction probability of about 10 -5, matching laboratory measurements of the reaction probability. For both carpet and duct materials, surfaces become progressively quenched (aging), losing the ability to react or otherwise take up ozone. He evaluated the functional form of aging and find that the reaction probability follows a power function with respect to the cumulative uptake of ozone. To understand ozone aging of surfaces, he developed several mathematical descriptions of aging based on two different mechanisms. The observed functional form of aging is mimicked by a model which describes ozone diffusion with internal reaction in a solid. He shows that the fleecy nature of carpet materials in combination with the model of ozone diffusion below a fiber surface and internal reaction may explain the functional form and the magnitude of power function parameters observed due to ozone interactions with carpet. The ozone induced aldehyde emissions, measured from duct materials, were combined with an indoor air quality model to show that concentrations of aldehydes indoors may approach odorous levels. He shows that ducts are unlikely to be a significant sink for ozone due to the low reaction probability in combination with the short residence time of air in ducts.« less

  9. Challenges in Flying Quadrotor Unmanned Aerial Vehicle for 3d Indoor Reconstruction

    NASA Astrophysics Data System (ADS)

    Yan, J.; Grasso, N.; Zlatanova, S.; Braggaar, R. C.; Marx, D. B.

    2017-09-01

    Three-dimensional modelling plays a vital role in indoor 3D tracking, navigation, guidance and emergency evacuation. Reconstruction of indoor 3D models is still problematic, in part, because indoor spaces provide challenges less-documented than their outdoor counterparts. Challenges include obstacles curtailing image and point cloud capture, restricted accessibility and a wide array of indoor objects, each with unique semantics. Reconstruction of indoor environments can be achieved through a photogrammetric approach, e.g. by using image frames, aligned using recurring corresponding image points (CIP) to build coloured point clouds. Our experiments were conducted by flying a QUAV in three indoor environments and later reconstructing 3D models which were analysed under different conditions. Point clouds and meshes were created using Agisoft PhotoScan Professional. We concentrated on flight paths from two vantage points: 1) safety and security while flying indoors and 2) data collection needed for reconstruction of 3D models. We surmised that the main challenges in providing safe flight paths are related to the physical configuration of indoor environments, privacy issues, the presence of people and light conditions. We observed that the quality of recorded video used for 3D reconstruction has a high dependency on surface materials, wall textures and object types being reconstructed. Our results show that 3D indoor reconstruction predicated on video capture using a QUAV is indeed feasible, but close attention should be paid to flight paths and conditions ultimately influencing the quality of 3D models. Moreover, it should be decided in advance which objects need to be reconstructed, e.g. bare rooms or detailed furniture.

  10. Changes to indoor air quality as a result of relocating families from slums to public housing

    NASA Astrophysics Data System (ADS)

    Burgos, Soledad; Ruiz, Pablo; Koifman, Rosalina

    2013-05-01

    One largely unstudied benefit of relocating families from slums to public housing is the potential improvement in indoor air quality (IAQ). We compared families that moved from slums to public housing with those that remained living in slums in Santiago, Chile in terms of fine particulate matter (PM2.5) as main indicator of change. A cross-sectional study of 98 relocated families and 71 still living in slums was carried out, obtaining indoor and outdoor samples by a Personal Environmental Monitor. Home characteristics, including indoor air pollution sources were collected through questionnaires. Multivariate regression models included the intervention (public housing or slum), indoor pollution sources, outdoor PM2.5 and family characteristics as predictors. Indoor PM2.5 concentrations were higher in slums (77.8 μg m-3 [SD = 35.7 μg m-3]) than in public housing (55.7 μg m-3 [SD = 34.6 μg m-3], p < 0.001). Differences between indoor and outdoor PM2.5 were significant only in the slum houses. The multivariate analysis showed that housing intervention significantly decreased indoor PM2.5 (10.4 μg m-3) after adjusting by the other predictors. Outdoor PM2.5 was the main predictor of indoor PM2.5. Other significant factors were water heating fuels and indoor smoking. Having infants 1-23 months was associated with a lowering of indoor PM2.5. Our results suggest that a public housing program that moves families from slums to public housing improves indoor air quality directly and also indirectly through air pollution sources.

  11. Quantification of indoor and outdoor volatile organic compounds (VOCs) in pubs and cafés in Pamplona, Spain

    NASA Astrophysics Data System (ADS)

    Parra, M. A.; Elustondo, D.; Bermejo, R.; Santamaría, J. M.

    Indoor and outdoor concentrations of volatile organic compounds (VOCs) were measured in 30 pubs and cafés (13 smoking, 13 non-smoking and 4 mixed atmospheres) in Pamplona city, Spain. The samples were obtained using a sampling pocket pump connected to stainless steel tubes filled with Tenax TA, and subsequently analysed by means of GC-MS coupled to a thermal desorption unit. The levels registered were found to be generally higher indoors. Smoking, cleaning products and the entrance of outdoor pollutants were identified as the main sources of these compounds, the later being especially relevant in non-smoking areas. BTEX concentrations were higher during the winter months and higher in smoking areas also.

  12. Quantitative assessment of bio-aerosols contamination in indoor air of University dormitory rooms.

    PubMed

    Hayleeyesus, Samuel Fekadu; Ejeso, Amanuel; Derseh, Fikirte Aklilu

    2015-07-01

    The purpose of this study is to provide insight into how students are exposed to indoor bio-aerosols in the dormitory rooms and to figure out the major possible factors that govern the contamination levels. The Bio-aerosols concentration level of indoor air of thirty dormitory rooms of Jimma University was determined by taking 120 samples. Passive air sampling technique; the settle plate method using open Petri-dishes containing different culture media was employed to collect sample twice daily. The range of bio-aerosols contamination detected in the dormitory rooms was 511-9960 CFU/m(3) for bacterial and 531-6568 CFU/m(3) for fungi. Based on the criteria stated by WHO expert group, from the total 120 samples 95 of the samples were above the recommended level. The statistical analysis showed that, occupancy were significantly affected the concentrations of bacteria that were measured in all dormitory rooms at 6:00 am sampling time (p-value=0.000) and also the concentrations of bacteria that were measured in all dormitory rooms were significantly different to each other (p-value=0.013) as of their significance difference in occupancy (p-value=0.000). Moreover, there were a significant different on the contamination level of bacteria at 6:00 am and 7:00 pm sampling time (p=0.015), whereas there is no significant difference for fungi contamination level for two sampling times (p= 0.674). There is excessive bio-aerosols contaminant in indoor air of dormitory rooms of Jimma University and human occupancy produces a marked concentration increase of bacterial contamination levels and most fungi species present into the rooms air of Jimma University dormitory were not human-borne.

  13. Quantitative assessment of bio-aerosols contamination in indoor air of University dormitory rooms

    PubMed Central

    Hayleeyesus, Samuel Fekadu; Ejeso, Amanuel; Derseh, Fikirte Aklilu

    2015-01-01

    Objectives The purpose of this study is to provide insight into how students are exposed to indoor bio-aerosols in the dormitory rooms and to figure out the major possible factors that govern the contamination levels. Methodology The Bio-aerosols concentration level of indoor air of thirty dormitory rooms of Jimma University was determined by taking 120 samples. Passive air sampling technique; the settle plate method using open Petri-dishes containing different culture media was employed to collect sample twice daily. Results The range of bio-aerosols contamination detected in the dormitory rooms was 511–9960 CFU/m3 for bacterial and 531–6568 CFU/m3 for fungi. Based on the criteria stated by WHO expert group, from the total 120 samples 95 of the samples were above the recommended level. The statistical analysis showed that, occupancy were significantly affected the concentrations of bacteria that were measured in all dormitory rooms at 6:00 am sampling time (p-value=0.000) and also the concentrations of bacteria that were measured in all dormitory rooms were significantly different to each other (p-value=0.013) as of their significance difference in occupancy (p-value=0.000). Moreover, there were a significant different on the contamination level of bacteria at 6:00 am and 7:00 pm sampling time (p=0.015), whereas there is no significant difference for fungi contamination level for two sampling times (p= 0.674). Conclusion There is excessive bio-aerosols contaminant in indoor air of dormitory rooms of Jimma University and human occupancy produces a marked concentration increase of bacterial contamination levels and most fungi species present into the rooms air of Jimma University dormitory were not human-borne. PMID:26609289

  14. The Development and Validation of the Mood-based Indoor Tanning Scale.

    PubMed

    Carcioppolo, Nick; Chen, Yixin; John, Kevin K; Gonzalez, Andrea Martinez; King, Andy J; Morgan, Susan E; Hu, Shasa

    2017-01-01

    Research indicates that mood-based motivations may be an important predictor of indoor tanning bed use and may be related to indoor tanning dependence. Problematically, little research has been conducted to develop a psychometric measure of mood-based tanning motivations. The current study seeks to develop and validate the moodbased indoor tanning scale (MITS). Two studies were conducted to identify and verify the MITS factor structure as well as assess construct validity. Study 1 was conducted at 5 geographically diverse universities in the United States. Study 2 was conducted by using a national online sample in the United States. Results from study 1 specified the factor structure of the MITS. Results from study 2 suggest that a one-point increase in the MITS measure corresponds with using indoor tanning beds 11 more times in the past year. These findings demonstrate that moodbased tanning motivations are a strong predictor of indoor tanning intentions and behavior. Further, they suggest that health behavior researchers and healthcare practitioners can use the MITS to assess the extent to which mood-based motivations impact indoor tanning bed use.

  15. A framework for modeling non-steady-state concentrations of semivolatile organic compounds indoors ― I: Emissions from diffusional sources and sorption by interior surfaces

    EPA Science Inventory

    Over the past two decades, more than 20 mass transfer models have been developed for the sources, sinks, and barriers for volatile and semivolatile organic compounds (VOCs and SVOCs) in the indoor environment. While these models have greatly improved our understanding of VOC and ...

  16. Volatile organic compounds in industrial, urban, and suburban areas: Sources and exposures

    NASA Astrophysics Data System (ADS)

    Jia, Chunrong

    This research was aimed at evaluating and refining sampling and analytical methods for airborne volatile organic compounds (VOCs), and at characterizing concentrations and potential exposures of VOCs found in indoor and ambient air in industrial, urban and suburban communities. A new analytical strategy of combining selective ion monitoring (SIM) and scan mode mass spectrometer analyses was developed and evaluated. This strategy improved sensitivity and selectivity without extra cost or calibration efforts. An intermittent active sampling method for collecting VOCs, which has not been previously evaluated, was compared to continuous active and passive sampling methods with the aim of obtaining long-term integrated measurements. Results obtained by the three methods agreed over a wide concentration range after accounting for the sampling rate. Intermittent sampling provides greater flexibility with respect to sampling period and flow rate, and enables the use of multi-bed adsorbents that increase the range of VOCs that can be monitored. VOC concentrations were measured inside and outside of 159 residences in suburban (Ann Arbor), urban (Ypsilanti) and urban/industrial (Dearborn) communities in southeastern Michigan from 2004 to 2005. A total of 53 and 46 VOCs were detected indoors and outdoors, respectively. Outdoors, benzene, toluene, p,m-xylene and carbon tetrachloride had the highest concentrations, and differences were seen between cities and seasons. Factor analyses identified four types of outdoor sources: vehicle exhaust/gasoline vapor, industrial solvents, biogenic emissions, and industrial sources. Indoors, benzene, toluene, p,m-xylene, n-heptane, alpha-pinene and d-limonene had the highest concentrations. Indoor to outdoor concentration ratios ranged from 1 to 10 for most compounds. Higher indoor concentrations were associated with the presence of attached garages, recent renovations, indoor smoking, residence age, infrequent window/door opening, high CO2 concentration, lower ventilation, and community. Factor analyses identified up to ten VOC source types in residences. This is one of the most comprehensive VOC surveys conducted in the US since 2000. A semi-parametric probability framework was developed to characterize VOC mixtures in residences. High concentration VOC mixtures resulted from the presence of several features (e.g. strong sources and ventilation conditions), and many characteristics of the observed mixtures could be represented using multivariate and correlated lognormal distributions.

  17. MULTIMEDIA CONCENTRATIONS OF PAH IN SEVERAL DAY CARE CENTERS

    EPA Science Inventory

    Concentrations of polycyclic aromatic hydrocarbons were measured in nine day care centers in the spring of 1997. Indoor and outdoor air, food and beverages, indoor dust, and outdoor play area soil were sampled. The mean sums of 20 target PAH concentrations were 265 and 199 ng...

  18. INDOOR, OUTDOOR, AND PERSONAL AIR EXPOSURES TO PARTICLES, ELEMENTS, AND NICOTINE FOR 178 RESIDENTS OF RIVERSIDE, CALIFORNIA

    EPA Science Inventory

    Personal, indoor, and outdoor concentrations of inhalable particles and 15 elements were measured for a probability sample of 178 persons representing 139,000 nonsmoking residents of Riverside, California. ewly designed personal monitors were employed. ersonal exposures often exc...

  19. Epistemic assessment of radon level of offices in Hong Kong

    NASA Astrophysics Data System (ADS)

    Wong, L. T.; Mui, K. W.; Law, K. Y.; Hui, P. S.

    People spend most of their life working indoors. Human exposure to various air pollutants changed its importance in nature from outdoor to indoor. As some of the pollutant sources basically originate from the building envelope that could not be removed or is costly to mitigate, the remaining questions are: how the indoor air quality (IAQ) is monitored and how the information could be used for the environmental control system to achieve the best air quality delivery. Indoor radon level could be measured with a number of sampling approaches and used to determine the acceptance of an IAQ with respect to certain exposure limits. In determining the acceptable IAQ of a space, this study proposes that the measured indoor radon level must be accompanied with the confidence levels of the assessment. Radon levels in Hong Kong offices were studied by a cross-sectional measurement in 216 typical offices and a year-round longitudinal measurement in one office. The results showed that 96.5% (94.0-99.0% at 95% confidence interval) and 98.6% (97.0% to >99.9% at 95% confidence interval) of the sampled offices would satisfy action radon levels of 150 and 200 Bq m -3, respectively. The same results were then used to quantify the prior knowledge on radon level distributions of an office and the probable errors of the adopted sampling schemes. This study proposes an epistemic approach, with the prior knowledge and a sample test result, to assess the acceptance against an action radon level of an office in Hong Kong. With the certainty of the test results determined for judgmental purposes, it is possible to apply the method to an office for follow-up tests of acceptance.

  20. Evaporative Cooler Use Influences Temporal Indoor Relative Humidity but Not Dust Mite Allergen Levels in Homes in a Semi-Arid Climate

    PubMed Central

    Johnston, James D.; Tuttle, Steven C.; Nelson, Morgan C.; Bradshaw, Rebecca K.; Hoybjerg, Taylor G.; Johnson, Julene B.; Kruman, Bryce A.; Orton, Taylor S.; Cook, Ryan B.; Eggett, Dennis L.; Weber, K. Scott

    2016-01-01

    Concerns about energy consumption and climate change make residential evaporative coolers a popular alternative to central air conditioning in arid and semi-arid climates. However, evaporative coolers have been shown to significantly increase indoor relative humidity and dust mite allergen levels in some studies, while showing no association in other studies. Improved measurement of temporal fluctuations in indoor relative humidity may help identify factors that promote mite growth in homes in dry climates. Dust samples and continuous indoor relative humidity measurements were collected from homes with central air conditioning and homes with evaporative coolers in Utah. Samples were collected over two seasons, winter/spring (Jan–Apr) and summer (July–Sept), 2014. Dust samples were analyzed for Der p 1 and Der f 1 using a two-site monoclonal antibody-based enzyme-linked immunosorbent assay (ELISA) analysis. Housing characteristics including age of home, occupant density, and age of mattresses, furniture, and carpeting were also measured. Positive Der p 1 or Der f 1 samples were found in 25.0% of the homes and there was no difference in mean allergen levels by type of air conditioning. Indoor relative humidity was significantly higher in homes with evaporative coolers compared to those with central air conditioning during the summer. Homes with evaporative coolers also spent significantly more time during summer above 55.0% and 65.0% relative humidity compared to central air homes, but not above 75.0%. Findings from this study suggest that increased humidity from evaporative coolers may not be sufficient to exceed the critical equilibrium humidity or maintain humidity excursions for sufficient duration in relatively larger single-family homes in semi-arid climates to support mite growth and reproduction. PMID:26808528

  1. Evaporative Cooler Use Influences Temporal Indoor Relative Humidity but Not Dust Mite Allergen Levels in Homes in a Semi-Arid Climate.

    PubMed

    Johnston, James D; Tuttle, Steven C; Nelson, Morgan C; Bradshaw, Rebecca K; Hoybjerg, Taylor G; Johnson, Julene B; Kruman, Bryce A; Orton, Taylor S; Cook, Ryan B; Eggett, Dennis L; Weber, K Scott

    2016-01-01

    Concerns about energy consumption and climate change make residential evaporative coolers a popular alternative to central air conditioning in arid and semi-arid climates. However, evaporative coolers have been shown to significantly increase indoor relative humidity and dust mite allergen levels in some studies, while showing no association in other studies. Improved measurement of temporal fluctuations in indoor relative humidity may help identify factors that promote mite growth in homes in dry climates. Dust samples and continuous indoor relative humidity measurements were collected from homes with central air conditioning and homes with evaporative coolers in Utah. Samples were collected over two seasons, winter/spring (Jan-Apr) and summer (July-Sept), 2014. Dust samples were analyzed for Der p 1 and Der f 1 using a two-site monoclonal antibody-based enzyme-linked immunosorbent assay (ELISA) analysis. Housing characteristics including age of home, occupant density, and age of mattresses, furniture, and carpeting were also measured. Positive Der p 1 or Der f 1 samples were found in 25.0% of the homes and there was no difference in mean allergen levels by type of air conditioning. Indoor relative humidity was significantly higher in homes with evaporative coolers compared to those with central air conditioning during the summer. Homes with evaporative coolers also spent significantly more time during summer above 55.0% and 65.0% relative humidity compared to central air homes, but not above 75.0%. Findings from this study suggest that increased humidity from evaporative coolers may not be sufficient to exceed the critical equilibrium humidity or maintain humidity excursions for sufficient duration in relatively larger single-family homes in semi-arid climates to support mite growth and reproduction.

  2. Evaluation of ionic air purifiers for reducing aerosol exposure in confined indoor spaces.

    PubMed

    Grinshpun, S A; Mainelis, G; Trunov, M; Adhikari, A; Reponen, T; Willeke, K

    2005-08-01

    Numerous techniques have been developed over the years for reducing aerosol exposure in indoor air environments. Among indoor air purifiers of different types, ionic emitters have gained increasing attention and are presently used for removing dust particles, aeroallergens and airborne microorganisms from indoor air. In this study, five ionic air purifiers (two wearable and three stationary) that produce unipolar air ions were evaluated with respect to their ability to reduce aerosol exposure in confined indoor spaces. The concentration decay of respirable particles of different properties was monitored in real time inside the breathing zone of a human manikin, which was placed in a relatively small (2.6 m3) walk-in chamber during the operation of an ionic air purifier in calm air and under mixing air condition. The particle removal efficiency as a function of particle size was determined using the data collected with a size-selective optical particle counter. The removal efficiency of the more powerful of the two wearable ionic purifiers reached about 50% after 15 min and almost 100% after 1.5 h of continuous operation in the chamber under calm air conditions. In the absence of external ventilation, air mixing, especially vigorous one (900 CFM), enhanced the air cleaning effect. Similar results were obtained when the manikin was placed inside a partial enclosure that simulated an aircraft seating configuration. All three stationary ionic air purifiers tested in this study were found capable of reducing the aerosol concentration in a confined indoor space. The most powerful stationary unit demonstrated an extremely high particle removal efficiency that increased sharply to almost 90% within 5-6 min, reaching about 100% within 10-12 min for all particle sizes (0.3-3 microm) tested in the chamber. For the units of the same emission rate, the data suggest that the ion polarity per se (negative vs. positive) does not affect the performance but the ion emission rate does. The effects of particle size (within the tested range) and properties (NaCl, PSL, Pseudomonas fluorescens bacteria) as well as the effects of the manikin's body temperature and its breathing on the ionic purifier performance were either small or insignificant. The data suggest that the unipolar ionic air purifiers are particularly efficient in reducing aerosol exposure in the breathing zone when used inside confined spaces with a relatively high surface-to-volume ratio. Ionic air purifiers have become increasingly popular for removing dust particles, aeroallergens and airborne microorganisms from indoor air in various settings. While the indoor air cleaning effect, resulting from unipolar and bipolar ion emission, has been tested by several investigators, there are still controversial claims (favorable and unfavorable) about the performance of commercially available ionic air purifiers. Among the five tested ionic air purifiers (two wearable and three stationary) producing unipolar air ions, the units with a higher ion emission rate provided higher particle removal efficiency. The ion polarity (negative vs. positive), the particle size (0.3-3 microm) and properties (NaCl, PSL, Pseudomonas fluorescens bacteria), as well as the body temperature and breathing did not considerable affected the ionization-driven particle removal. The data suggest that the unipolar ionic air purifiers are particularly efficient in reducing aerosol exposure in the breathing zone when they are used inside confined spaces with a relatively high surface-to-volume ratio (such as automobile cabins, aircraft seating areas, bathrooms, cellular offices, small residential rooms, and animal confinements). Based on our experiments, we proposed that purifiers with a very high ion emission rate be operated in an intermittent mode if used indoors for extended time periods. As the particles migrate to and deposit on indoor surfaces during the operation of ionic air purifiers, some excessive surface contamination may occur, which introduces the need of periodic cleaning these surfaces.

  3. Assessment of indoor PM2.5 in different residential environments

    NASA Astrophysics Data System (ADS)

    Yassin, Mohamed F.; AlThaqeb, Bothaina E. Y.; Al-Mutiri, Eman A. E.

    2012-09-01

    The indoor air quality (IAQ) as assessed by PM2.5 (particulate matter with an aerodynamic diameter of less than 2.5 μm) was measured at indoor settings in various residential houses which were located in different local environments across Kuwait. The indoor house settings included kitchen, living room, and bedrooms. Samples were collected from houses over 24 h. PM2.5 was estimated using a Dust-Trak personal sampler. Results were analyzed and compared with the US Environmental Protection Agencies (EPA) and World Health Organization (WHO) standards and guidelines. The results demonstrated that kitchens have the highest PM2.5 concentration probably due to cooking activities; the bedroom has the lowest PM2.5 concentration. The study shows that Kuwait indoor residential pollution is among the worst in comparison with other countries.

  4. Polybrominated diphenyl ethers (PBDEs) in U.S. computers and domestic carpet vacuuming: possible sources of human exposure.

    PubMed

    Schecter, Arnold; Päpke, Olaf; Joseph, Jean Elizabeth; Tung, Kuang-Chi

    2005-04-09

    Polybrominated diphenyl ethers (PBDEs), a type of brominated flame retardant chemically and toxicologically similar to polychlorinated biphenyls (PCBs), are a class of emerging environmental and human contaminants. They have recently been detected in U.S. milk, blood, and food at the highest levels in the world. This pilot study was undertaken with the aim of determining levels of PBDE in the U.S. indoor environment, to assess the potential exposure to PBDEs from computer surfaces and carpets. Food of animal origin is the usual source of polychlorinated dibenzo-p-dioxin (PCDD), polychlorinated dibenzofurans (PCDF), and PCBs in humans, but there may also be environmental sources for intake of PBDEs. It was also our aim to characterize the PBDE congener profile in these indoor environmental samples. Four computer wipe samples and 9 domestic vacuum-sweeping samples were analyzed for 13 PBDE congeners, PBDEs 17 (2,2',4), 28 (2,4,4'?), 47 (2,2',4,4'?), 66 (2,3',4,4'?), 77 (3,3',4,4'?), 85 (2,2',3,4,4'?), 99 (2,2'4,4',5), 100 (2,2',4,4',6), 138 (2,2',3,4,4',5'?), 153 (2,2',4,4',5,5'?), 154 (2,2',4,4',5,6'?), 183 (2,2',3,4,4',5',6), and 209 (2,2',3,3',4,4',5,5',6,6'?). All samples tested positive for PBDEs. PBDE 209 was the dominant congener in all 4 computer wipe samples and in 7 out of the 9 vacuum dust samples. The congener profiles observed in this study varied considerably, a finding that has been observed previously. However these congener profiles differ from the pattern seen in U.S. human milk, human blood and in food, where PBDEs 47 and 99 predominate.

  5. Classification of buildings mold threat using electronic nose

    NASA Astrophysics Data System (ADS)

    Łagód, Grzegorz; Suchorab, Zbigniew; Guz, Łukasz; Sobczuk, Henryk

    2017-07-01

    Mold is considered to be one of the most important features of Sick Building Syndrome and is an important problem in current building industry. In many cases it is caused by the rising moisture of building envelopes surface and exaggerated humidity of indoor air. Concerning historical buildings it is mostly caused by outdated raising techniques among that is absence of horizontal isolation against moisture and hygroscopic materials applied for construction. Recent buildings also suffer problem of mold risk which is caused in many cases by hermetization leading to improper performance of gravitational ventilation systems that make suitable conditions for mold development. Basing on our research there is proposed a method of buildings mold threat classification using electronic nose, based on a gas sensors array which consists of MOS sensors (metal oxide semiconductor). Used device is frequently applied for air quality assessment in environmental engineering branches. Presented results show the interpretation of e-nose readouts of indoor air sampled in rooms threatened with mold development in comparison with clean reference rooms and synthetic air. Obtained multivariate data were processed, visualized and classified using a PCA (Principal Component Analysis) and ANN (Artificial Neural Network) methods. Described investigation confirmed that electronic nose - gas sensors array supported with data processing enables to classify air samples taken from different rooms affected with mold.

  6. Airborne microorganisms associated with waste management and recovery: biomonitoring methodologies.

    PubMed

    Coccia, Anna Maria; Gucci, Paola Margherita Bianca; Lacchetti, Ines; Paradiso, Rosa; Scaini, Federica

    2010-01-01

    This paper presents preliminary results from a year-long indoor bioaerosol monitoring performed in three working environments of a municipal composting facility treating green and organic waste. Composting, whereby organic matter is stabilized through aerobic decomposition, requires aeration, causing the dispersion of microbial particles (microorganisms and associated toxins). Waste can, therefore, become a potential source of biological hazard. Bioaerosol samples were collected on a monthly basis. Through a comparison of results obtained using two samplers - the Surface Air System DUO SAS 360 and the BioSampler - the study aimed at assessing the presence of biological pollutants, and at contributing to the definition of standard sampling methods for bioaerosols leading, eventually, to the establishment of exposure limits for these occupational pollutants.

  7. ASSESSMENT OF VAPOR INTRUSION USING INDOOR AND SUB-SLAB AIR SAMPLING

    EPA Science Inventory

    The objective of this investigation was to develop a method for evaluating vapor intrusion using indoor and sub-slab air measurement and at the same time directly assist EPA’s New England Regional Office in evaluating vapor intrusion in 15 homes and one business near the former R...

  8. QUANTIFICATION OF STACHYBOTRYS CHARTARUM CONIDIA IN INDOOR DUST USING REAL TIME, FLUORESCENT PROBE-BASED DETECTION OF PCR PRODUCTS

    EPA Science Inventory

    Analyses of fungal spores or conidia in indoor dust samples can be useful for determining the contamination status of building interiors and in signaling instances where potentially harmful exposures of building occupants to these organisms may exist. A recently developed method ...

  9. METHOD AND LOCATION OF GROUND WATER SAMPLING: IMPACT ON ATTENUATION FACTORS FOR ASSESSING IMPACT ON VAPOR INTRUSION

    EPA Science Inventory

    The Draft EPA Subsurface Vapor Intrusion Guidance Document was established to "address the incremental increases in exposures and risks from subsurface contaminants that my be intruding into indoor air". The document utilizes attenuation factors based on indoor air/soil gas or i...

  10. Fungal and Bacterial Communities in Indoor Dust Follow Different Environmental Determinants.

    PubMed

    Weikl, Fabian; Tischer, Christina; Probst, Alexander J; Heinrich, Joachim; Markevych, Iana; Jochner, Susanne; Pritsch, Karin

    2016-01-01

    People spend most of their time inside buildings and the indoor microbiome is a major part of our everyday environment. It affects humans' wellbeing and therefore its composition is important for use in inferring human health impacts. It is still not well understood how environmental conditions affect indoor microbial communities. Existing studies have mostly focussed on the local (e.g., building units) or continental scale and rarely on the regional scale, e.g. a specific metropolitan area. Therefore, we wanted to identify key environmental determinants for the house dust microbiome from an existing collection of spatially (area of Munich, Germany) and temporally (301 days) distributed samples and to determine changes in the community as a function of time. To that end, dust samples that had been collected once from the living room floors of 286 individual households, were profiled for fungal and bacterial community variation and diversity using microbial fingerprinting techniques. The profiles were tested for their association with occupant behaviour, building characteristics, outdoor pollution, vegetation, and urbanization. Our results showed that more environmental and particularly outdoor factors (vegetation, urbanization, airborne particulate matter) affected the community composition of indoor fungi than of bacteria. The passage of time affected fungi and, surprisingly, also strongly affected bacteria. We inferred that fungal communities in indoor dust changed semi-annually, whereas bacterial communities paralleled outdoor plant phenological periods. These differences in temporal dynamics cannot be fully explained and should be further investigated in future studies on indoor microbiomes.

  11. Fungal and Bacterial Communities in Indoor Dust Follow Different Environmental Determinants

    PubMed Central

    Weikl, Fabian; Tischer, Christina; Probst, Alexander J.; Heinrich, Joachim; Markevych, Iana; Jochner, Susanne; Pritsch, Karin

    2016-01-01

    People spend most of their time inside buildings and the indoor microbiome is a major part of our everyday environment. It affects humans’ wellbeing and therefore its composition is important for use in inferring human health impacts. It is still not well understood how environmental conditions affect indoor microbial communities. Existing studies have mostly focussed on the local (e.g., building units) or continental scale and rarely on the regional scale, e.g. a specific metropolitan area. Therefore, we wanted to identify key environmental determinants for the house dust microbiome from an existing collection of spatially (area of Munich, Germany) and temporally (301 days) distributed samples and to determine changes in the community as a function of time. To that end, dust samples that had been collected once from the living room floors of 286 individual households, were profiled for fungal and bacterial community variation and diversity using microbial fingerprinting techniques. The profiles were tested for their association with occupant behaviour, building characteristics, outdoor pollution, vegetation, and urbanization. Our results showed that more environmental and particularly outdoor factors (vegetation, urbanization, airborne particulate matter) affected the community composition of indoor fungi than of bacteria. The passage of time affected fungi and, surprisingly, also strongly affected bacteria. We inferred that fungal communities in indoor dust changed semi-annually, whereas bacterial communities paralleled outdoor plant phenological periods. These differences in temporal dynamics cannot be fully explained and should be further investigated in future studies on indoor microbiomes. PMID:27100967

  12. Impact of Middle Eastern dust storms on indoor and outdoor composition of bioaerosol

    NASA Astrophysics Data System (ADS)

    Goudarzi, Gholamreza; Soleimani, Zahra; Sorooshian, Armin; Marzouni, Mohammad Bagherian; Maleki, Heidar

    2016-08-01

    The presence of microbes in airborne aerosol particles, especially dust, is a major public health concern in desert regions. This study is the first of its kind to examine the effect of dust storms on indoor and outdoor microbial air quality at a hospital on the western side of Iran (city of Ahvaz), which is notorious for being highly vulnerable to dust emissions. Air samples were collected inside and outside of the hospital environment for six months, with the unique advantage of this study being that the region and duration of measurements allow for a clear comparison between dusty and normal days. On normal days, the average concentrations (outdoor/indoor) of bacteria and fungi were 423/329 cfu m-3 and 596/386 cfu m-3, respectively, which increased to 1257/406 cfu m-3 and 1116/550 cfu m-3 on dust event days. Indoor/Outdoor ratios for bacteria and fungi are lower on dust event days (0.26-0.60) versus normal days (0.44-0.95). Bacillus spp., Micrococcus spp., Streptomyces spp., and Staphylococcus spp. were the dominant bacteria both indoors and outdoors on normal and dust event days. Gram positive bacteria exhibited higher concentrations than Gram negative bacteria in both outdoor and indoor air samples as well as during both normal and dust event days. The data suggest that Gram positive bacteria are more resistant to undesirable outdoor conditions (e.g., high incident solar radiation) as compared to Gram negative ones. These results have implications for other populated arid regions where more stringent control of indoor air quality can greatly benefit public health.

  13. Finishing of wood

    Treesearch

    R. Sam Williams

    1999-01-01

    The primary function of any wood finish (paint, varnish, and stain, for example) is to protect the wood surface, help maintain a certain appearance, and provide a cleanable surface. Although wood can be used both outdoors and indoors without finishing, unfinished wood surfaces exposed to the weather change color, are roughened by photodegradation and surface checking,...

  14. Generic aspects of the airborne spread of human pathogens indoors and emerging air decontamination technologies.

    PubMed

    Ijaz, M Khalid; Zargar, Bahram; Wright, Kathryn E; Rubino, Joseph R; Sattar, Syed A

    2016-09-02

    Indoor air can be an important vehicle for a variety of human pathogens. This review provides examples of airborne transmission of infectious agents from experimental and field studies and discusses how airborne pathogens can contaminate other parts of the environment to give rise to secondary vehicles leading air-surface-air nexus with possible transmission to susceptible hosts. The following groups of human pathogens are covered because of their known or potential airborne spread: vegetative bacteria (staphylococci and legionellae), fungi (Aspergillus, Penicillium, and Cladosporium spp and Stachybotrys chartarum), enteric viruses (noro- and rotaviruses), respiratory viruses (influenza and coronaviruses), mycobacteria (tuberculous and nontuberculous), and bacterial spore formers (Clostridium difficile and Bacillus anthracis). An overview of methods for experimentally generating and recovering airborne human pathogens is included, along with a discussion of factors that influence microbial survival in indoor air. Available guidelines from the U.S. Environmental Protection Agency and other global regulatory bodies for the study of airborne pathogens are critically reviewed with particular reference to microbial surrogates that are recommended. Recent developments in experimental facilities to contaminate indoor air with microbial aerosols are presented, along with emerging technologies to decontaminate indoor air under field-relevant conditions. Furthermore, the role that air decontamination may play in reducing the contamination of environmental surfaces and its combined impact on interrupting the risk of pathogen spread in both domestic and institutional settings is discussed. Copyright © 2016. Published by Elsevier Inc.

  15. Effectiveness of urban shelter-in-place—II: Residential districts

    NASA Astrophysics Data System (ADS)

    Chan, Wanyu R.; Nazaroff, William W.; Price, Phillip N.; Gadgil, Ashok J.

    In the event of a short-term, large-scale toxic chemical release to the atmosphere, shelter-in-place (SIP) may be used as an emergency response to protect public health. We modeled hypothetical releases using realistic, empirical parameters to explore how key factors influence SIP effectiveness for single-family dwellings in a residential district. Four classes of factors were evaluated in this case study: (a) time scales associated with release duration, SIP implementation delay, and SIP termination; (b) building air-exchange rates, including air infiltration and ventilation; (c) the degree of sorption of toxic chemicals to indoor surfaces; and (d) the shape of the dose-response relationship for acute adverse health effects. Houses with lower air leakage are more effective shelters, and thus variability in the air leakage of dwellings is associated with varying degrees of SIP protection in a community. Sorption on indoor surfaces improves SIP effectiveness by lowering the peak indoor concentrations and reducing the amount of contamination in the indoor air. Nonlinear dose-response relationships imply substantial reduction in adverse health effects from lowering the peak exposure concentration. However, if the scenario is unfavorable for indefinite sheltering (e.g. sheltering in leaky houses for protection against a nonsorbing chemical with a linear dose-response), the community must implement SIP without delay and exit from shelter when it first becomes safe to do so. Otherwise, the community can be subjected to even greater risk than if they did not take shelter indoors.

  16. Indoor organic and inorganic pollutants: In-situ formation and dry deposition in Southeastern Brazil

    NASA Astrophysics Data System (ADS)

    Allen, Andrew G.; Miguel, Antonio H.

    We have measured indoor and outdoor levels of particle- and gas-phase pollutants, collected in offices, restaurants and a hotel at six different sites in and around the cities of São Paulo and Campinas, Brazil, during summer 1993. Gas-phase species included acetic acid, formic acid, nitrous acid, hydrochloric acid, sulfur dioxide, nitric acid, oxalic acid, and pyruvic acid. Fine mode (< 3 μm dp) and coarse mode (> 3 μm dp) species measured included chloride, potassium, acetate, nitrate, magnesium, formate, sodium, pyruvate, nitrite, calcium, sulfate, oxalate, and ammonium. One sample (˜ 6 h) was simultaneously collected indoors and outdoors at each site during regular working hours. Indoor samplers were located ca. 1.5 m from the floor, and the outdoors immediately outside the window. Indoor/outdoor concentration ratios suggest that fine potassium chloride was produced indoors in appreciable amounts at both restaurants studied and, to a lesser extent, in the three offices as well. Indoor fine nitrate particles found in restaurants appear to have been produced by fuel combustion; a small fraction may have resulted from dry deposition of nitric acid onto existing fine particles. Indoor and outdoor concentrations of fine- and coarse-mode acetate suggest their production at all sites. The average concentration of gas-phase acetic acid was 42 μg m -3 indoors compared to 9.0 μg m -3 outdoors. In-situ formation of nitrous acid and acetic acid appears to have occurred at all indoor sites. High levels of formic and acetic acids were produced indoors at a pizzeria that used wood for cooking. Nitrous acid average concentrations for all sites were 8.4 μm m -3 indoors and 3.2 μm m -3 outdoors. Indoor/outdoor ratios at all sites suggest that dry deposition indoors may have occurred for hydrochloric acid, nitric acid and sulfur dioxide and that fine-mode sulfate infiltrate buildings from outside at most sites.

  17. Personal formaldehyde exposure level in the gross anatomy dissecting room at College of Medicine King Saud University Riyadh.

    PubMed

    Vohra, Muhammad Saeed

    2011-03-01

    This study was conducted to correlate the personal formaldehyde (FA) exposure levels of instructors and students with the indoor FA concentrations in gross anatomy laboratory at King Saud University. The personal FA levels of instructors and students are higher than the indoor FA concentration in the gross anatomy laboratory. The gross anatomy laboratory at college of medicine, King Saud University Riyadh, was observed for indoor FA concentration and the personal exposure levels of instructors and the medical students during the 4th, 10th and 14th weeks of the dissection sessions. All air samples were collected by the diffusive sampling device and analyzed by using high performance liquid chromatography (HPLC). The personal exposure level of FA was higher than the indoor concentration, and the personal exposure levels of instructors were higher than that of the students. The concentration of FA was also higher in the center of the room than the corners and near the doors. Both the indoor FA concentrations and personal FA exposure levels are higher near the dissecting table than at locations away from it during the gross anatomy laboratory sessions. Thus, the instructors and students are exposed to the higher concentration of FA than the general population.

  18. Comparison, association, and risk assessment of phthalates in floor dust at different indoor environments in Delaware, USA.

    PubMed

    Bi, Xiaolong; Yuan, Shoujun; Pan, Xiaojun; Winstead, Cherese; Wang, Qiquan

    2015-01-01

    This study aimed to compare and assess phthalate contamination in various indoor environments. In this study, 44 floor dust samples from different indoor environments in Delaware, USA were collected and analyzed for 14 phthalates using gas chromatography-mass spectrometry. Phthalates were detected in all dust samples with the total concentration ranging from 84 to 7117 mg kg(-1). DEHP (di-2-ethylhexyl phthalate), BzBP (benzylbutyl phthalate), DBP (dibutyl phthalate), and DiBP (di-isobutyl phthalate) were both the most frequently and abundantly detected phthalates. The average concentration of total phthalates in dust from offices, student dorms, gyms, stores, and daycare centers was found to be significantly or insignificantly (P = 0.05) higher than that in dust from houses and apartments. Plastic flooring materials and the application of floor care chemical products were positively associated with total phthalate concentration in floor dust. Toxicological risk assessment indicated that an investigated daycare center in this study was the only indoor environment that may cause the intake amount of DEHP of infants, toddlers, and children via dust ingestion to exceed the reference dose established by the U.S. Environmental Protection Agency (USEPA). Regular monitoring on phthalate contamination in sensitive indoor environments is recommended.

  19. Research on the operation control strategy of the cooling ceiling combined with fresh air system

    NASA Astrophysics Data System (ADS)

    Huang, Tao; Li, Hao

    2018-03-01

    The cooling ceiling combined with independent fresh air system was built by TRNSYS. And the cooling effects of the air conditioning system of an office in Beijing in a summer typical day were simulated. Based on the “variable temperature” control strategy, the operation strategy of “variable air volume auxiliary adjustment” was put forward. The variation of the indoor temperature, the indoor humidity, the temperature of supplying water and the temperature of returning water were simulated under the two control strategies. The energy consumption of system during the whole summer was compared by utilizing the two control strategies, and the indoor thermal comfort was analyzed. The optimal control strategy was proposed under the condition that the condensation on the surface of the cooling ceiling is not occurred and the indoor thermal comfort is satisfied.

  20. New insight into the levels, distribution and health risk diagnosis of indoor and outdoor dust-bound FRs in colder, rural and industrial zones of Pakistan.

    PubMed

    Khan, Muhammad Usman; Li, Jun; Zhang, Gan; Malik, Riffat Naseem

    2016-09-01

    This is the first robust study designed to probe selected flame retardants (FRs) in the indoor and outdoor dust of industrial, rural and background zones of Pakistan with special emphasis upon their occurrence, distribution and associated health risk. For this purpose, we analyzed FRs such as polybrominated diphenylethers (PBDEs), dechlorane plus (DP), novel brominated flame retardants (NBFRs) and organophosphate flame retardants (OPFRs) in the total of 82 dust samples (indoor and outdoor) collected three from each zone: industrial, rural and background. We found higher concentrations of FRs (PBDEs, DP, NBFRs and OPFRs) in industrial zones as compared to the rural and background zones. Our results reveal that the concentrations of studied FRs are relatively higher in the indoor dust samples being compared with the outdoor dust and they are ranked as: ∑OPFRs > ∑NBFRs > ∑PBDEs > ∑DP. A significant correlation in the FRs levels between the indoor and outdoor dust suggest the potential intermixing of these compounds between them. The principal component analysis/multiple linear regression predicts the percent contribution of FRs from different consumer products in the indoor and outdoor dust of industrial, rural and background zones to trace their source origin. The FRs detected in the background zones reveal the dust-bound FRs suspended in the air might be shifted from different warmer zones or consumers products available/used in the same zones. Hazard quotient (HQ) for FRs via indoor and outdoor dust intake at mean and high dust scenarios to the exposed populations (adults and toddlers) are found free of risk (HQ < 1) in the target zones. Furthermore, our nascent results will provide a baseline record of FRs (PBDEs, DP, NBFRs and OPFRs) concentrations in the indoor and outdoor dust of Pakistan. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Measuring childhood abuse and neglect in a group of female indoor sex workers in the Netherlands: a confirmatory factor analysis of the Dutch version of the Childhood Trauma Questionnaire-Short Form.

    PubMed

    Daalder, Annelies L; Bogaerts, Stefan

    2011-06-01

    Confirmatory factor analysis was performed on the responses to the Dutch version of the Childhood Trauma Questionnaire-Short Form from a sample of 123 female indoor sex workers in The Netherlands. Results indicate the expected five-factor structure fit the data well. In line with Bernstein and others, the instrument was a valid measure of retrospective childhood abuse and neglect in this sample.

  2. Air filtration systems and restrictive access conditions improve indoor air quality in clinical units: Penicillium as a general indicator of hospital indoor fungal levels.

    PubMed

    Araujo, Ricardo; Cabral, João Paulo; Rodrigues, Acácio Gonçalves

    2008-03-01

    High-efficiency particulate air (HEPA) filters do not completely prevent nosocomial fungal infections. The first aim of this study was to evaluate the impact of different filters and access conditions upon airborne fungi in hospital facilities. Additionally, this study identified fungal indicators of indoor air concentrations. Eighteen rooms and wards equipped with different air filter systems, and access conditions were sampled weekly, during 16 weeks. Tap water samples were simultaneously collected. The overall mean concentration of atmospheric fungi for all wards was 100 colony forming units/m(3). We found a direct proportionality between the levels of the different fungi in the studied atmospheres. Wards with HEPA filters at positive air flow yielded lower fungal levels. Also, the existence of an anteroom and the use of protective clothes were associated to the lowest fungal levels. Principal component analysis showed that penicillia afforded the best separation between wards' air fungal levels. Fungal strains were rarely recovered from tap water samples. In addition to air filtration systems, some access conditions to hospital units, like presence of anteroom and use of protective clothes, may prevent high fungal air load. Penicillia can be used as a general indicator of indoor air fungal levels at Hospital S. João.

  3. A sensitive method using SPME pre-concentration for the quantification of aromatic amines in indoor air.

    PubMed

    Lucaire, Vincent; Schwartz, Jean-Jacques; Delhomme, Olivier; Ocampo-Torres, Ruben; Millet, Maurice

    2018-03-01

    Monitoring the levels of aliphatic and aromatic amines (AA) in indoor air is important to protect human health because of exposure to these compounds through diet and inhalation. A sampling and analytical method using XAD-2 cartridges and gas chromatography coupled to mass spectrometry used for assessing 25 AA in different smoking and non-smoking indoor environment was developed. After sampling and delivering 1 m 3 of air (6-8 h sampling), an adsorbent was ultrasonically extracted with acetonitrile, concentrated to 1 mL and diluted in 25 mL of water (pH = 9; 5% NaCl), and then extracted for 40 min at 80 °C using a divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fiber and injected in a GC/MS system. With this method, 22 of the 25 AA can be analyzed with detection limits up to five times lower than that of classic liquid injection. Benzylamine, 3-aminophenol, and 4-aminophenol were not detected with the solid-phase micro-extraction (SPME) method. It can be assumed that aminophenols required a derivatization step for their analysis by GC as these molecules were not detected regardless of the injection mode used. Graphical abstract Analysis of aromatic amines in indoor air by SPME-GC/MS.

  4. Effects of room airflow on accurate determination of PUF-PAS sampling rates in the indoor environment.

    PubMed

    Herkert, Nicholas J; Hornbuckle, Keri C

    2018-05-23

    Accurate and precise interpretation of concentrations from polyurethane passive samplers (PUF-PAS) is important as more studies show elevated concentrations of PCBs and other semivolatile air toxics in indoor air of schools and homes. If sufficiently reliable, these samplers may be used to identify local sources and human health risks. Here we report indoor air sampling rates (Rs) for polychlorinated biphenyl congeners (PCBs) predicted for a frequently used double-dome and a half-dome PUF-PAS design. Both our experimentally calibrated (1.10 ± 0.23 m3 d-1) and modeled (1.08 ± 0.04 m3 d-1) Rs for the double-dome samplers compare well with literature reports for similar rooms. We determined that variability of wind speeds throughout the room significantly (P < 0.001) effected uptake rates. We examined this effect using computational fluid dynamics modeling and 3-D sonic anemometer measurements and found the airflow dynamics to have a significant but small impact on the precision of calculated airborne concentrations. The PUF-PAS concentration measurements were within 27% and 10% of the active sampling concentration measurements for the double-dome and half-dome designs, respectively. While the half-dome samplers produced more consistent concentration measurements, we find both designs to perform well indoors.

  5. A kinetic analysis of manual wheelchair propulsion during start-up on select indoor and outdoor surfaces.

    PubMed

    Koontz, Alicia M; Cooper, Rory A; Boninger, Michael L; Yang, Yusheng; Impink, Bradley G; van der Woude, Lucas H V

    2005-01-01

    The objective of this study was to conduct a kinetic analysis of manual wheelchair propulsion during start-up on select indoor and outdoor surfaces. Eleven manual wheelchairs were fitted with a SMART(Wheel) and their users were asked to push on a course consisting of high- and low-pile carpet, indoor tile, interlocking concrete pavers, smooth level concrete, grass, hardwood flooring, and a sidewalk with a 5-degree grade. Peak resultant force, wheel torque, mechanical effective force, and maximum resultant force rate of rise were analyzed during start-up for each surface and normalized relative to their steady-state values on the smooth level concrete. Additional variables included peak velocity, distance traveled, and number of strokes in the first 5 s of the trial. We compared biomechanical data between surfaces using repeated-measures mixed models and paired comparisons with a Bonferroni adjustment. Applied resultant force (p = 0.0154), wheel torque (p < 0.0001), and mechanical effective force (p = 0.0047) were significantly different between surfaces. The kinetic values for grass, interlocking pavers, and ramp ascent were typically higher compared with tile, wood, smooth level concrete, and high- and low-pile carpet. Users were found to travel shorter distances up the ramp and across grass (p < 0.0025) and had a higher stroke count on the ramp (p = 0.0124). While peak velocity was not statistically different, average velocity was slower for the ramp and grass, which indicates greater wheelchair/user deceleration between strokes. The differences noted between surfaces highlight the importance of evaluating wheelchair propulsion ability over a range of surfaces.

  6. Resuspension of biological particles from indoor surfaces: Effects of humidity and air swirl.

    PubMed

    Salimifard, Parichehr; Rim, Donghyun; Gomes, Carlos; Kremer, Paul; Freihaut, James D

    2017-04-01

    Human exposure to airborne particles can lead to adverse health outcomes such as respiratory and allergic symptoms. Understanding the transport mechanism of respirable particles in occupied spaces is a first step towards assessing inhalation exposure. Several studies have contributed to the current knowledge of particle resuspension from indoor surfaces; however, few published studies are available on resuspension of biological particles from indoor surfaces. The objective of this study is to investigate the impacts of humidity and air swirl on resuspension of biological particles from floor and duct surfaces. Controlled laboratory experiments were conducted under varying degrees of humidity and airflow conditions. Resuspension rates of five types of particles (quartz, dust mite, cat fur, dog fur, and bacterial spore-Bacillus thuringiensis as an anthrax simulant) were determined for two types of floor surface (carpet and linoleum) and a duct surface (galvanized sheet metal). The results show that the particle property of being hydrophilic or hydrophobic plays an important role in particle resuspension rate. Resuspension rates of hydrophilic dust mite particles increase up to two orders of magnitude as relative humidity (RH) decreased from 80% to 10% at 25°C. However, resuspension rates of cat fur and dog fur particles that are hydrophobic are within the measurement error range (±15%) over 10-80% RH. With regard to resuspension of bacterial spores (Bacillus thuringiensis) from a duct surface, the resuspension rates are substantially affected by air swirl velocity and particle size. However, no discernible increase in particle resuspension was observed with duct vibration. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. 3rd hand smoking; heterogeneous oxidation of nicotine and secondary aerosol formation in the indoor environment

    NASA Astrophysics Data System (ADS)

    Petrick, Lauren; Dubowski, Yael

    2010-05-01

    Tobacco smoking is well known as a significant source of primary indoor air pollutants. However, only recently has it been recognized that the impact of Tobacco smoking may continue even after the cigarette has been extinguished (i.e., third hand smoke) due to the effect of indoor surfaces. These surfaces may affect the fate of tobacco smoke in the form of secondary reactions and pollutants, including secondary organic aerosol (SOA) formation. Fourier Transform Infrared spectrometry with Attenuated Total Reflection (FTIR-ATR) in tandem with a Scanning Mobility Particle Sizing (SMPS) system was used to monitor the ozonation of cellulose sorbed nicotine and resulting SOA formation. SOA formation began at onset of ozone introduction ([O3] = 60 ± 5 ppb) with a size distribution of dp ≤ 25 nm, and was determined to be a result of heterogeneous reaction (opposed to homogeneous). SOA yield from reacted surface nicotine was on the order of 10 %. Simultaneous to SOA monitoring, FTIR-ATR spectra showed surface changes in the nicotine film as the reaction progressed, revealing a pseudo first-order surface reaction rate of 0.0026 ± 0.0008 min-1. Identified surface oxidation products included: cotinine, myosmine, methylnicotinamide and nicotyrine. Surface reaction rate was found to be partially inhibited at high relative humidity. Given the toxicity of some of the identified products (e.g., cotinine has shown potential mutagenicity and teratogenicity) and that small particles may contribute to adverse health effects, the present study indicates that exposure to 3rd hand smoke ozonation products may pose additional health risks.

  8. Residential indoor and personal PM10 exposures of ambient origin based on chemical components.

    PubMed

    Xu, Jia; Bai, Zhipeng; You, Yan; Zhou, Jian; Zhang, Jiefeng; Niu, Can; Liu, Yating; Zhang, Nan; He, Fei; Ding, Xiao

    2014-07-01

    Many studies have focused on the relationships of particulate matter between indoor, outdoor and personal exposure; however, considerable uncertainties remain regarding the portion of indoor particles and personal exposure of ambient origin. As part of the Particle Exposure Assessment for Community Elderly (PEACE) study in Tianjin, China, we have further interpreted the relationships between personal, residential indoor, outdoor and community PM10 (particulate matter with aerodynamic diameters of less than 10 μm). Comparisons of the chemical compositions of PM10 samples were performed using the coefficient of divergence (COD). A robust regression method, least-trimmed squared (LTS) regression, was used to estimate the infiltration factors of PM10 from residential outdoor to indoor environments based on the particulate component concentrations. Personal exposures of ambient origin were also estimated. A relatively good correlation was found between the personal and indoor PM10 samples with respect to chemical composition. The infiltration factors (Finf) of the residential indoor-outdoor PM10 were 0.74±0.31 (mean±SD) in summer and 0.44±0.22 in winter, with medians of 0.98 and 0.48, respectively. The residential outdoor contributions to the indoor environments were 87±55 μg/m(3) in summer and 80±54 μg/m(3) in winter, with medians of 75 μg/m(3) and 61 μg/m(3), respectively. The personal exposures of ambient origin were 92±44 μg/m(3) in summer and 89±47 μg/m(3) in winter, with medians of 81 μg/m(3) and 80 μg/m(3), respectively. This study indicated that the infiltrations in an urbanized area in North China exhibited a seasonal difference: the residential outdoor contributions to residential indoor environments were larger in summer due to the higher use of natural ventilation. The personal exposures of ambient origin were comparable during the different seasons, whereas those of non-ambient origin were higher in summer than in winter.

  9. Source apportionment of indoor, outdoor and personal PM2.5 exposure of pregnant women in Barcelona, Spain

    NASA Astrophysics Data System (ADS)

    Minguillón, M. C.; Schembari, A.; Triguero-Mas, M.; de Nazelle, A.; Dadvand, P.; Figueras, F.; Salvado, J. A.; Grimalt, J. O.; Nieuwenhuijsen, M.; Querol, X.

    2012-11-01

    Exposure to air pollution has been shown to adversely affect foetal development in the case of pregnant women. The present study aims to investigate the PM composition and sources influencing personal exposure of pregnant women in Barcelona. To this end, indoor, outdoor and personal exposure measurements were carried out for a selection of 54 pregnant women between November 2008 and November 2009. PM2.5 samples were collected during two consecutive days and then analysed for black smoke (BS), major and trace elements, and polycyclic aromatic hydrocarbons (PAHs) concentrations. Personal information such as commuting patterns and cosmetics use was also collected. PM2.5 concentrations were higher for personal samples than for indoor and outdoor environments. Indoor, outdoor and personal BS and sulphate concentrations were strongly correlated, although some specific indoor and outdoor sulphate sources may exist. Average trace elements concentrations were similar indoor, outdoor and for personal exposure, but the correlations were moderate for most of them. Most of the PAHs concentrations showed strong correlations indoor-outdoor. A source apportionment analysis of the PM composition data by means of a Positive Matrix Factorization (PMF) resulted in the identification of six sources for the outdoor and indoor environments: secondary sulphate, fueloil + sea salt (characterized by V, Ni, Na and Mg), mineral, cigarette (characterized by K, Ce, Cd, benzo(k)fluoranthene and benzo(ghi)perylene), road traffic (characterized by BS and low weight PAHs), and industrial (characterized by Pb, Sn, Cu, Mn and Fe). For personal exposure two specific sources were found: cosmetics (characterized by abundance of Ca, Li, Ti and Sr and the absence of Al) and train/subway (characterized by Fe, Mn, Cu and Ba). The contribution of the sources varied widely among women, especially for cigarette (from zero to up to 4 μg m-3), train/subway (up to more than 6 μg m-3) and cosmetics (up to more than 5 μg m-3). The source contributions showed generally strong correlations indoor-outdoor although the infiltration efficiencies varied among homes. This study emphasizes the importance of relying on personal exposure in epidemiological studies assessing the impact of air pollution on human health.

  10. Effect of Ventilation Strategies on Residential Ozone Levels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Iain S.; Sherman, Max H.

    Elevated outdoor ozone levels are associated with adverse health effects. Because people spend the vast majority of their time indoors, reduction in indoor levels of ozone of outdoor origin would lower population exposures and might also lead to a reduction in ozone-associated adverse health effects. In most buildings, indoor ozone levels are diminished with respect to outdoor levels to an extent that depends on surface reactions and on the degree to which ozone penetrates the building envelope. Ozone enters buildings from outdoors together with the airflows that are driven by natural and mechanical means, including deliberate ventilation used to reducemore » concentrations of indoor-generated pollutants. When assessing the effect of deliberate ventilation on occupant health one should consider not only the positive effects on removing pollutants of indoor origin but also the possibility that enhanced ventilation might increase indoor levels of pollutants originating outdoors. This study considers how changes in residential ventilation that are designed to comply with ASHRAE Standard 62.2 might influence indoor levels of ozone. Simulation results show that the building envelope can contribute significantly to filtration of ozone. Consequently, the use of exhaust ventilation systems is predicted to produce lower indoor ozone concentrations than would occur with balanced ventilation systems operating at the same air-­exchange rate. We also investigated a strategy for reducing exposure to ozone that would deliberately reduce ventilation rates during times of high outdoor ozone concentration while still meeting daily average ventilation requirements.« less

  11. Carbonyl levels in indoor and outdoor air in Mexico City and Xalapa, Mexico.

    PubMed

    Báez, Armando; Padilla, Hugo; García, Rocío; Torres, Ma del Carmen; Rosas, Irma; Belmont, Raúl

    2003-01-20

    Carbonyl compounds in air were measured at two houses, three museums, and two offices. All sites lacked air-conditioning systems. Although indoor and outdoor air was measured simultaneously at each site, the sites themselves were sampled in different dates. Mean concentrations were higher in indoor air. Outdoor means concentrations of acetone were the highest in all sites, ranging from 12 to 60 microg m(-3). In general, formaldehyde and acetaldehyde had similar mean concentrations, ranging from 4 to 32 and 6 to 28 microg m(-3), respectively. Formaldehyde and acetone mean indoor concentrations were the highest, ranging from 11 to 97 and 17 to 89 microg m(-3), respectively, followed by acetaldehyde with 5 to 47 microg m(-3). Formaldehyde and acetaldehyde had the highest mean concentration in the offices where there were smokers. Propionaldehyde and butyraldehyde concentrations did not show definite differences between indoor and outdoor air. In general, the highest outdoor and indoor hourly concentrations were observed from 10:00 to 15:00 h. Mean indoor/outdoor ratios of carbonyls exceeded 1. Formaldehyde and acetaldehyde risks were higher in smoking environments. Copyright 2002 Elsevier Science B.V.

  12. Indoor Tanning Among High School Students in the United States, 2009 and 2011

    PubMed Central

    Guy, Gery P.; Berkowitz, Zahava; Tai, Eric; Holman, Dawn M.; Jones, Sherry Everett; Richardson, Lisa C.

    2015-01-01

    IMPORTANCE Indoor tanning is associated with an increased risk of skin cancer, including melanoma, and is particularly dangerous for younger and more frequent indoor tanners. OBJECTIVE To examine the prevalence of indoor tanning and frequent indoor tanning (≥10 times during the 12 months before each survey) and their association with health-related behaviors. DESIGN, SETTING, AND PARTICIPANTS A cross-sectional study examined data from the 2009 and 2011 national Youth Risk Behavior Surveys, which used nationally representative samples of US high school students representing approximately 15.5 million students each survey year. The study included 25 861 students who answered the indoor tanning question. MAIN OUTCOMES AND MEASURES The prevalence of indoor tanning and frequent indoor tanning were examined as well as their association with demographic characteristics and health-related behaviors using multivariable logistic regression modeling. RESULTS The prevalence of indoor tanning was greater among female, older, and non-Hispanic white students. Indoor tanning was highest among female students aged 18 years or older, with 31.5% engaging in indoor tanning in 2011, and among non-Hispanic white female students, with 29.3% engaging in indoor tanning in 2011. Among female students, the adjusted prevalence of indoor tanning decreased from 26.4% in 2009 to 20.7% in 2011. Among female and male students, indoor tanning was associated with other risk-taking behaviors, such as binge drinking (P < .001 and P = .006, respectively), unhealthy weight control practices (P < .001, for both), and having sexual intercourse (P < .001, for both). Additionally, indoor tanning among female students was associated with using illegal drugs (P < .001) and having sexual intercourse with 4 or more persons (P = .03); use among male students was associated with taking steroids without a physician’s prescription (P < .001), smoking cigarettes daily (P = .03), and attempting suicide (P = .006). More than half of respondents engaging in indoor tanning reported frequent use of the devices. CONCLUSIONS AND RELEVANCE Indoor tanning is common among high school students. Public health efforts are needed to change social norms regarding tanned skin and to increase awareness, knowledge, and behaviors related to indoor tanning. The clustering of risky behaviors suggests a need for coordinated, multifaceted approaches, including primary care physician counseling, to address such behaviors among adolescents. PMID:24577222

  13. Children's exposure to brominated flame retardants in indoor environments - A review.

    PubMed

    Malliari, Eleftheria; Kalantzi, Olga-Ioanna

    2017-11-01

    The aim of this review is to present up-to-date research on children's exposure to brominated flame retardants (BFRs) in indoor environments. Large geographical variations were observed for all BFRs [polybrominated diphenyl ethers (PBDEs), hexabromocyclododecane (HBCDD), tetrabromobisphenol A (TBBPA)], with the highest concentrations of PBDEs measured in North America (BDE-47) and Europe (BDE-209), where higher concentrations of PBDEs are present in dust from houses, daycare centers and primary schools. In Asia the highest PBDE concentrations were measured in China, near e-waste recycling areas. In the Middle East, Australia and Africa BFR levels were low in most indoor spaces. Asian countries also have the highest concentrations of TBBPA and HBCDD, followed by European countries. Fewer studies have been conducted measuring novel and emerging BFRs (NBFRs or EBFRs), of which decabromodiphenylethane (DBDPE) has the highest concentration in indoor environments, especially in China. The vast majority of children's exposure studies have been conducted in houses, sampling either dust or air, and considerably fewer in schools, daycare centers, cars and public facilities, despite BFR levels being comparable to (or sometimes even higher than) house dust. Relatively fewer studies focused on children's tissues such as serum, and only two studied exposure via mouthing toys. Alternative noninvasive sampling matrices that may act as surrogates for exposure to BFRs such as handwipes and silicone wristbands have recently started to gain momentum, because of the ease of sampling, faster collection time and better correlations to serum than house dust. Feces sampling is another promising alternative to children's serum that warrants further research. While many studies have associated different indoor environment characteristics, there is a knowledge gap on the association between children's behaviour and activity patterns and their exposure to BFRs, as well as data on infant exposure to BFRs via baby products. Results from the studies showed that dust ingestion was the dominant exposure pathway for most studied BFRs compared to indoor air inhalation and dermal contact, especially for infants and toddlers who have higher exposures than older children. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Implementation of Wi-Fi Signal Sampling on an Android Smartphone for Indoor Positioning Systems.

    PubMed

    Liu, Hung-Huan; Liu, Chun

    2017-12-21

    Collecting and maintaining radio fingerprint for wireless indoor positioning systems involves considerable time and labor. We have proposed the quick radio fingerprint collection (QRFC) algorithm which employed the built-in accelerometer of Android smartphones to implement step detection in order to assist in collecting radio fingerprints. In the present study, we divided the algorithm into moving sampling (MS) and stepped MS (SMS), and describe the implementation of both algorithms and their comparison. Technical details and common errors concerning the use of Android smartphones to collect Wi-Fi radio beacons were surveyed and discussed. The results of signal sampling experiments performed in a hallway measuring 54 m in length showed that in terms of the amount of time required to complete collection of access point (AP) signals, static sampling (SS; a traditional procedure for collecting Wi-Fi signals) took at least 2 h, whereas MS and SMS took approximately 150 and 300 s, respectively. Notably, AP signals obtained through MS and SMS were comparable to those obtained through SS in terms of the distribution of received signal strength indicator (RSSI) and positioning accuracy. Therefore, MS and SMS are recommended instead of SS as signal sampling procedures for indoor positioning algorithms.

  15. Implementation of Wi-Fi Signal Sampling on an Android Smartphone for Indoor Positioning Systems

    PubMed Central

    Liu, Chun

    2017-01-01

    Collecting and maintaining radio fingerprint for wireless indoor positioning systems involves considerable time and labor. We have proposed the quick radio fingerprint collection (QRFC) algorithm which employed the built-in accelerometer of Android smartphones to implement step detection in order to assist in collecting radio fingerprints. In the present study, we divided the algorithm into moving sampling (MS) and stepped MS (SMS), and describe the implementation of both algorithms and their comparison. Technical details and common errors concerning the use of Android smartphones to collect Wi-Fi radio beacons were surveyed and discussed. The results of signal sampling experiments performed in a hallway measuring 54 m in length showed that in terms of the amount of time required to complete collection of access point (AP) signals, static sampling (SS; a traditional procedure for collecting Wi-Fi signals) took at least 2 h, whereas MS and SMS took approximately 150 and 300 s, respectively. Notably, AP signals obtained through MS and SMS were comparable to those obtained through SS in terms of the distribution of received signal strength indicator (RSSI) and positioning accuracy. Therefore, MS and SMS are recommended instead of SS as signal sampling procedures for indoor positioning algorithms. PMID:29267234

  16. VOC SAMPLING IN THE WATER TABLE/CAPILLARY FRINGE AREA FOR ASSESSING IMPACT ON VAPOR INTRUSION AND INDOOR AIR QUALITY

    EPA Science Inventory

    Vapor intrusion has been determined to be a major pathway for increased indoor air contamination from volatile organic contaminants (VOCs) at certain contaminated sites. In order to properly assess vapor intrusion, it is important to adequately evaluate VOC concentrations in the...

  17. Participant-Based Monitoring of Indoor and Outdoor Nitrogen Dioxide, Volatile Organic Compounds, and Polycyclic Aromatic Hydrocarbons among MICA-Air Households

    EPA Science Inventory

    The Mechanistic Indicators of Childhood Asthma (MICA) study in Detroit, Michigan introduced a participant-based approach to reduce the resource burden associated with collection of indoor and outdoor residential air sampling data. A subset of participants designated as MICA-Air c...

  18. Knowledge of the Effects of Indoor Air Quality on Health among Women in Jordan

    ERIC Educational Resources Information Center

    Madanat, Hala; Barnes, Michael D.; Cole, Eugene C.

    2008-01-01

    Objective: To assess the extent of knowledge about symptoms relating to respiratory illnesses and home environments among a random sample of 200 urban Jordanian women. Method: This customized, validated, cross-sectional questionnaire evaluated the knowledge of these women about the association between the indoor environment and health, the…

  19. GAS PARTICLE PARTITIONING OF CHLORDANES IN COUPLED INDOOR/OUTDOOR AIR SAMPLES FROM THREE U.S. CITIES

    EPA Science Inventory

    Concentrations of six Chlordane species (trans-chlordane, cis-chlordane, trans-nonachlor, cis-nonachlor, oxychlordane and MC5) were measured indoors and outdoors at 157 non-smoking residences in three urban areas during June 1999-May 2000. These measu...

  20. TEMPORAL MOISTURE CONTENT VARIABILITY BENEATH AND EXTERNAL TO A BUILDING AND THE POTENTIAL EFFECTS ON VAPOR INTRUSION RISK ASSESSMENT

    EPA Science Inventory

    Migration of vapors from organic chemicals residing in the subsurface into overlying buildings is known as vapor intrusion. Because of the difficulty in evaluating vapor intrusion by indoor air sampling, models are often employed to determine if a potential indoor inhalation exp...

  1. [Bacterial contamination of the indoor air in a transplant unit].

    PubMed

    Matoušková, Ivanka; Holý, Ondřej

    2013-12-01

    For one year (August 2010 to July 2011), microbial contamination of the indoor air in the Transplant Unit of the Haemato-Oncology Clinic, Olomouc University Hospital was monitored monthly. Twenty sampling sites were singled out and a total of 240 indoor air samples were collected. An MAS-100 air sampler (Merck, GER) was used, air flow rate of 100 liters per minute, 1 minute. The measured values of indoor air temperature were stable. The relative air humidity ranged from 17% to 68%. The highest average value of microbial air contamination was found in the "staff entry room" (1170 CFU/m3). The lowest microbial air contamination (150-250 CFU/m3) was measured in the patient isolation units. The most frequently isolated bacterial strains were coagulase-negative staphylococci (94.3%), followed by Micrococcus spp. (67%) and Bacillus subtilis (11%). It can be assumed that the -source of these airborne bacterial strains are both patients and medical staff. They are classified as -opportunistic pathogens and as such can cause hospital infections among haemato-oncology patients.

  2. Levels, distribution and human exposure of new non-BDE brominated flame retardants in the indoor dust of China.

    PubMed

    Qi, Hong; Li, Wen-Long; Liu, Li-Yan; Zhang, Zi-Feng; Zhu, Ning-Zheng; Song, Wei-Wei; Ma, Wan-Li; Li, Yi-Fan

    2014-12-01

    Indoor environment is an important source of human exposure to several toxicants, such as brominated flame retardants. This study presents the concentrations of 22 Non-BDE brominated flame retardants (NBFRs) in 81 indoor dust samples from 23 provinces across China in the winter of 2010. The concentrations of ΣNBFRs ranged from 6.3 to 20,000 ng/g, with a median concentration of 720 ng/g. DBDPE was the dominated compound, followed by HBCD and BEHTBP. Significant differences of concentrations were found between samples from rural and urban areas, and between family and public houses, indicating different applications of NBFRs. The geographical distribution of NBFRs highlighted several hotspots in North China, suggesting the influence of room temperature (heating). The exposure via dust ingestion of NBFRs was 3.8-14 times higher than that of dermal absorption. The toddlers demonstrated the highest exposure dose (9.6 ng/kg-bw/day) of NBFRs through indoor dust among all life stages. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Uranium-238 and thorium-232 series concentrations in soil, radon-222 indoor and drinking water concentrations and dose assessment in the city of Aldama, Chihuahua, Mexico.

    PubMed

    Colmenero Sujo, L; Montero Cabrera, M E; Villalba, L; Rentería Villalobos, M; Torres Moye, E; García León, M; García-Tenorio, R; Mireles García, F; Herrera Peraza, E F; Sánchez Aroche, D

    2004-01-01

    High-resolution gamma spectrometry was used to determine the concentration of 40K, 238U and 232Th series in soil samples taken from areas surrounding the city of Aldama, in Chihuahua. Results of indoor air short-time sampling, with diffusion barrier charcoal detectors, revealed relatively high indoor radon levels, ranging from 29 to 422 Bq/m3; the radon concentrations detected exceeded 148 Bq/m3 in 76% of the homes tested. Additionally, liquid scintillation counting showed concentrations of radon in drinking water ranging from 4.3 to 42 kBq/m3. The high activity of 238U in soil found in some places may be a result of the uranium milling process performed 20 years ago in the area. High radon concentrations indoor and in water may be explained by assuming the presence of uranium-bearing rocks underneath of the city, similar to a felsic dike located near Aldama. The estimated annual effective dose of gamma radiation from the soil and radon inhalation was 3.83 mSv.

  4. Investigation of the persistence of nerve agent degradation analytes on surfaces through wipe sampling and detection with ultrahigh performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Willison, Stuart A

    2015-01-20

    The persistence of chemical warfare nerve agent degradation analytes on surfaces is important, from indicating the presence of nerve agent on a surface to guiding environmental restoration of a site after a release. Persistence was investigated for several chemical warfare nerve agent degradation analytes on indoor surfaces and presents an approach for wipe sampling of surfaces, followed by wipe extraction and liquid chromatography-tandem mass spectrometry detection. Commercially available wipe materials were investigated to determine optimal wipe recoveries. Tested surfaces included porous/permeable (vinyl tile, painted drywall, and wood) and largely nonporous/impermeable (laminate, galvanized steel, and glass) surfaces. Wipe extracts were analyzed by ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). UPLC provides a separation of targeted degradation analytes in addition to being nearly four times faster than high-performance liquid chromatography, allowing for greater throughput after a large-scale contamination incident and subsequent remediation events. Percent recoveries from nonporous/impermeable surfaces were 60-103% for isopropyl methylphosphonate (IMPA), GB degradate; 61-91% for ethyl methylphosphonate (EMPA), VX degradate; and 60-98% for pinacolyl methylphosphonate (PMPA), GD degradate. Recovery efficiencies for methyl phosphonate (MPA), nerve agent degradate, and ethylhydrogen dimethylphosphonate (EHDMAP), GA degradate, were lower, perhaps due to matrix effects. Diisopropyl methylphosphonate, GB impurity, was not recovered from surfaces. The resulting detection limits for wipe extracts were 0.065 ng/cm(2) for IMPA, 0.079 ng/cm(2) for MPA, 0.040 ng/cm(2) for EMPA, 0.078 ng/cm(2) for EHDMAP, and 0.013 ng/cm(2) for PMPA. The data indicate that laboratories may hold wipe samples for up to 30 days prior to analysis. Target analytes were observed to persist on surfaces for at least 6 weeks.

  5. Characteristic variations in reflectance of surface soils

    NASA Technical Reports Server (NTRS)

    Stoner, E. R.; Baumgardner, M. F. (Principal Investigator)

    1982-01-01

    Surface soil samples from a wide range of naturally occurring soils were obtained for the purpose of studying the characteristic variations in soil reflectance as these variations relate to other soil properties and soil classification. A total 485 soil samples from the U.S. and Brazil representing 30 suborders of the 10 orders of 'Soil Taxonomy' was examined. The spectral bidirectional reflectance factor was measured on uniformly moist soils over the 0.52 to 2.32 micron wavelength range with a spectroradiometer adapted for indoor use. Five distinct soil spectral reflectance curve forms were identified according to curve shape, the presence or absence of absorption bands, and the predominance of soil organic matter and iron oxide composition. These curve forms were further characterized according to generically homogeneous soil properties in a manner similar to the subdivisions at the suborder level of 'Soil Taxonomy'. Results indicate that spectroradiometric measurements of soil spectral bidirectional reflectance factor can be used to characterize soil reflectance in terms that are meaningful to soil classification, genesis, and survey.

  6. Influence of relative humidity and gaseous ammonia on the nicotine sorption to indoor materials.

    PubMed

    Ongwandee, M; Sawanyapanich, P

    2012-02-01

    Sorption of nitrogen-containing organic constituents of environmental tobacco smoke may be influenced by ammonia, a common indoor gas, and relative humidity (RH). We quantified sorption kinetics and equilibria of nicotine with stainless steel, cotton-polyester curtain, and polypropylene carpet at 0%, 50%, and 90% RH and in the presence of ammonia using a 10-l stainless steel chamber. Nicotine was introduced into the chamber by flash evaporating 50 μl of pure liquid. Kinetic sorption parameters were determined by fitting a mass balance model to experimental results using a nonlinear regression. Results show that an equilibrium partition coefficient, k(e) , of nicotine tended to increase as the RH increased for the curtain and carpet. Adsorbed water may contribute to an increase in available sites for nicotine sorption on the surface. In the presence of 20- and 40-ppm NH(3) , the values of k(e) for carpet were decreased by 14-40% at 50% and 90% RH, but the effect of NH(3) was not observed at 0% RH. The values of k(e) ranged from 54 to 152 m. Our findings indicate the relative importance of nicotine sorption to surfaces is dependent on the relative humidity and the presence of ammonia. This research demonstrates that relative humidity and gaseous ammonia can influence nicotine sorption to common indoor surfaces, i.e., curtains and carpets. Increasing the relative humidity from dry to modest appears to enhance the sorptive capacity. Presence of the typical range of gaseous ammonia concentrations can reduce the nicotine sorption in a humid environment but does not affect the sorptive capacity in the absence of added water. Thus, studies on the dynamic sorption of other alkaloids or amine constituents of environmental tobacco smoke to indoor surfaces should consider the impact of water vapor concentration because of the interaction of water with the surface and sorbates. Furthermore, the mixture of gaseous amines may participate in adsorption site competition. © 2011 John Wiley & Sons A/S.

  7. Solar Transparent Radiators by Optical Nanoantennas.

    PubMed

    Jönsson, Gustav; Tordera, Daniel; Pakizeh, Tavakol; Jaysankar, Manoj; Miljkovic, Vladimir; Tong, Lianming; Jonsson, Magnus P; Dmitriev, Alexandre

    2017-11-08

    Architectural windows are a major cause of thermal discomfort as the inner glazing during cold days can be several degrees colder than the indoor air. Mitigating this, the indoor temperature has to be increased, leading to unavoidable thermal losses. Here we present solar thermal surfaces based on complex nanoplasmonic antennas that can raise the temperature of window glazing by up to 8 K upon solar irradiation while transmitting light with a color rendering index of 98.76. The nanoantennas are directional, can be tuned to absorb in different spectral ranges, and possess a structural integrity that is not substrate-dependent, and thus they open up for application on a broad range of surfaces.

  8. A model to predict radon exhalation from walls to indoor air based on the exhalation from building material samples.

    PubMed

    Sahoo, B K; Sapra, B K; Gaware, J J; Kanse, S D; Mayya, Y S

    2011-06-01

    In recognition of the fact that building materials are an important source of indoor radon, second only to soil, surface radon exhalation fluxes have been extensively measured from the samples of these materials. Based on this flux data, several researchers have attempted to predict the inhalation dose attributable to radon emitted from walls and ceilings made up of these materials. However, an important aspect not considered in this methodology is the enhancement of the radon flux from the wall or the ceiling constructed using the same building material. This enhancement occurs mainly because of the change in the radon diffusion process from the former to the latter configuration. To predict the true radon flux from the wall based on the flux data of building material samples, we now propose a semi-empirical model involving radon diffusion length and the physical dimensions of the samples as well as wall thickness as other input parameters. This model has been established by statistically fitting the ratio of the solution to radon diffusion equations for the cases of three-dimensional cuboidal shaped building materials (such as brick, concrete block) and one dimensional wall system to a simple mathematical function. The model predictions have been validated against the measurements made at a new construction site. This model provides an alternative tool (substitute to conventional 1-D model) to estimate radon flux from a wall without relying on ²²⁶Ra content, radon emanation factor and bulk density of the samples. Moreover, it may be very useful in the context of developing building codes for radon regulation in new buildings. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Indoor airborne particle sources and semi-volatile partitioning effect of outdoor fine PM in offices

    NASA Astrophysics Data System (ADS)

    Sangiorgi, G.; Ferrero, L.; Ferrini, B. S.; Lo Porto, C.; Perrone, M. G.; Zangrando, R.; Gambaro, A.; Lazzati, Z.; Bolzacchini, E.

    2013-02-01

    To date, few studies have focused on PM air quality in offices, despite the fact that a lot of people spend many working hours a day in such offices. The aim of the present study is to investigate PM1 and PM2.5 in offices in Milan (Northern Italy) and in the air outside those offices. The PM samples were analyzed to determine the entity of certain compounds with possible direct or indirect adverse effects on human health: PAHs, BpA, and water soluble inorganic ions. A good correlation between outdoor and indoor PM mass concentrations emerged (R2 ˜0.87). The maximum I/O concentration ratio was 0.92, suggesting that the indoor PM level was always lower than the outdoor level. The average infiltration factor, FINF, was 0.55, showing that about a half of the outdoor PM had come indoors. The indoor-generated particles, Cig, had values ranging from 0 to 4.4 μg m-3 (<25% of the indoor PM), showing that PM indoor sources had only made a limited contribution to total indoor PM. The results of the indoor-to-outdoor comparisons for the aforementioned chemical compounds demonstrate that the offices were characterized by the absence of effective indoor sources of particulate-bound PAHs and inorganic ions, whereas Cig was around 58% of the indoor concentration for BpA. Our analysis of the FINF data pointed to the presence of a volatilization effect from PM for semi-volatile compounds like ammonium nitrate and 4- or 5-ring PAHs, which affected the measurement of their FINF. We propose the introduction of a new and simple parameter, called volatilization correction, to take account of this effect.

  10. Phthalate esters (PAEs) in indoor PM10/PM2.5 and human exposure to PAEs via inhalation of indoor air in Tianjin, China

    NASA Astrophysics Data System (ADS)

    Zhang, Leibo; Wang, Fumei; Ji, Yaqin; Jiao, Jiao; Zou, Dekun; Liu, Lingling; Shan, Chunyan; Bai, Zhipeng; Sun, Zengrong

    2014-03-01

    In this study, filter samples of six Phthalate esters (PAEs) in indoor PM10 and PM2.5 were collected from thirteen homes in Tianjin, China. The results showed that the concentrations of Σ6PAEs in indoor PM10 and PM2.5 were in the range of 13.878-1591.277 ng m-3 and 7.266-1244.178 ng m-3, respectively. Dibutyl phthalate (DBP) was the most abundant compounds followed by di-2-ethylhexyl phthalate (DEHP) in indoor PM10 and PM2.5. Whereas DBP and dimethyl phthalate (DMP) were the predominant compounds in indoor air (gas-phase + particle-phase), the median values were 573.467 and 368.364 ng m-3 respectively. The earlier construction time, the lesser indoor area, the old decoration, the very crowded items coated with plastic and a lower frequency of dusting may lead to a higher level of PAEs in indoor environment. The six PAEs in indoor PM10 and PM2.5 were higher in summer than those in winter. The daily intake (DI) of six PAEs for five age groups through air inhalation in indoor air in Tianjin was estimated. The results indicated that the highest exposure dose was DBP in every age group, and infants experienced the highest total DIs (median: 664.332 ng kg-bw-1 day-1) to ∑6PAEs, whereas adults experienced the lowest total DIs (median: 155.850 ng kg-bw-1 day-1) to ∑6PAEs. So, more attention should be paid on infants in the aspect of indoor inhalation exposure to PAEs.

  11. An assessment of radiation doses at an educational institution 57.8 km away from the Fukushima Daiichi nuclear power plant 1 month after the nuclear accident.

    PubMed

    Tsuji, Masayoshi; Kanda, Hideyuki; Kakamu, Takeyasu; Kobayashi, Daisuke; Miyake, Masao; Hayakawa, Takehito; Mori, Yayoi; Okochi, Toshiyasu; Hazama, Akihiro; Fukushima, Tetsuhito

    2012-03-01

    On 11 March 2011, the Great East Japan Earthquake occurred. Due to this earthquake and subsequent tsunami, malfunctions occurred at the Fukushima Daiichi nuclear power plant. Radioactive material even reached the investigated educational institution despite being 57.8 km away from the power station. With the goal of ensuring the safety of our students, we decided to carry out a risk assessment of the premises of this educational institution by measuring radiation doses at certain locations, making it possible to calculate estimated radiation accumulation. Systematic sampling was carried out at measurement points spaced at regular intervals for a total of 24 indoor and outdoor areas, with 137 measurements at heights of 1 cm and 100 cm above the ground surface. Radiation survey meters were used to measure environmental radiation doses. Radiation dose rates and count rates were higher outdoors than indoors, and higher 1 cm above the ground surface than at 100 cm. Radiation doses 1 cm above the ground surface were higher on grass and moss than on asphalt and soil. The estimated radiation exposure for a student spending an average of 11 h on site at this educational institution was 9.80 μSv. Environmental radiation doses at our educational institution 57.8 km away from the Fukushima Daiichi nuclear power plant 1 month after the accident were lower than the national regulation dose for schools (3.8 μSv/h) at most points. Differences in radiation doses depending on outdoor surface properties are important to note for risk reduction.

  12. Evaluation of radon occurrence in groundwater from 16 geologic units in Pennsylvania, 1986–2015, with application to potential radon exposure from groundwater and indoor air

    USGS Publications Warehouse

    Gross, Eliza L.

    2017-05-11

    Results from 1,041 groundwater samples collected during 1986‒2015 from 16 geologic units in Pennsylvania, associated with 25 or more groundwater samples with concentrations of radon-222, were evaluated in an effort to identify variations in radon-222 activities or concentrations and to classify potential radon-222 exposure from groundwater and indoor air. Radon-222 is hereafter referred to as “radon.” Radon concentrations in groundwater greater than or equal to the proposed U.S. Environmental Protection Agency (EPA) maximum contaminant level (MCL) for public-water supply systems of 300 picocuries per liter (pCi/L) were present in about 87 percent of the water samples, whereas concentrations greater than or equal to the proposed alternative MCL (AMCL) for public water-supply systems of 4,000 pCi/L were present in 14 percent. The highest radon concentrations were measured in groundwater from the schists, gneisses, and quartzites of the Piedmont Physiographic Province.In this study, conducted by the U.S. Geological Survey in cooperation with the Pennsylvania Department of Health and the Pennsylvania Department of Environmental Protection, groundwater samples were aggregated among 16 geologic units in Pennsylvania to identify units with high median radon concentrations in groundwater. Graphical plots and statistical tests were used to determine variations in radon concentrations in groundwater and indoor air. Median radon concentrations in groundwater samples and median radon concentrations in indoor air samples within the 16 geologic units were classified according to proposed and recommended regulatory limits to explore potential radon exposure from groundwater and indoor air. All of the geologic units, except for the Allegheny (Pa) and Glenshaw (Pcg) Formations in the Appalachian Plateaus Physiographic Province, had median radon concentrations greater than the proposed EPA MCL of 300 pCi/L, and the Peters Creek Schist (Xpc), which is in the Piedmont Physiographic Province, had a median radon concentration greater than the EPA proposed AMCL of 4,000 pCi/L. Median concentrations of radon in groundwater and indoor air were determined to differ significantly among the geologic units (Kruskal-Wallis test, significance probability, p<0.001), and Tukey’s test indicated that radon concentrations in groundwater and indoor air in the Peters Creek Schist (Xpc) were significantly higher than those in the other units. Also, the Peters Creek Schist (Xpc) was determined to be the area with highest potential of radon exposure from groundwater and indoor air and one of two units with the highest percentage of population assumed to be using domestic self-supplied water (81 percent), which puts the population at greater potential of exposure to radon from groundwater.Potential radon exposure determined from classification of geologic units by median radon concentrations in groundwater and indoor air according to proposed and recommended regulatory limits is useful for drawing general conclusions about the presence, variation, and potential radon exposure in specific geologic units, but the associated data and maps have limitations. The aggregated indoor air radon data have spatial accuracy limitations owing to imprecision of geocoded test locations. In addition, the associated data describing geologic units and the public water supplier’s service areas have spatial and interpretation accuracy limitations. As a result, data and maps associated with this report are not recommended for use in predicting individual concentrations at specific sites nor for use as a decision-making tool for property owners to decide whether to test for radon concentrations at specific locations. Instead, the data and maps are meant to promote awareness regarding potential radon exposure in Pennsylvania and to point out data gaps that exist throughout the State.

  13. Identification of penetration path and deposition distribution of radionuclides in houses by experiments and numerical model

    NASA Astrophysics Data System (ADS)

    Hirouchi, Jun; Takahara, Shogo; Iijima, Masashi; Watanabe, Masatoshi; Munakata, Masahiro

    2017-11-01

    In order to lift of an evacuation order in evacuation areas and return residents to their homes, human dose assessments are required. However, it is difficult to exactly assess indoor external dose rate because the indoor distribution and infiltration pathways of radionuclides are unclear. This paper describes indoor and outdoor dose rates measured in eight houses in the difficult-to-return area in Fukushima Prefecture and identifies the distribution and main infiltration pathway of radionuclides in houses. In addition, it describes dose rates calculated with a Monte Carlo photon transport code to aid a thorough understanding of the measurements. The measurements and calculations indicate that radionuclides mainly infiltrate through visible openings such as vents, windows, and doors, and then deposit near these visible openings; however, they hardly infiltrate through sockets and air conditioning outlets. The measurements on rough surfaces such as bookshelves implies that radionuclides discharged from the Fukushima-Daiichi nuclear power plant did not deposit locally on rough surfaces.

  14. Barriers and opportunities for passive removal of indoor ozone

    NASA Astrophysics Data System (ADS)

    Gall, Elliott T.; Corsi, Richard L.; Siegel, Jeffrey A.

    2011-06-01

    This paper presents a Monte Carlo simulation to assess passive removal materials (PRMs) that remove ozone with no additional energy input and minimal byproduct formation. Distributions for air exchange rate in a subset of homes in Houston, Texas, were taken from the literature and combined with background ozone removal rates in typical houses and previous experimentally determined ozone deposition velocities to activated carbon cloth and gypsum wallboard PRMs. The median ratio of indoor to outdoor ozone was predicted to be 0.16 for homes with no PRMs installed and ranged from 0.047 to 0.12 for homes with PRMs. Median values of ozone removal effectiveness in these homes ranged from 22% to 68% for the conditions investigated. Achieving an ozone removal effectiveness above 50% in half of the homes would require installing a large area of PRMs and providing enhanced air speed to transport pollutants to PRM surfaces. Challenges associated with achieving this removal include optimizing indoor transport and aesthetic implications of large surface areas of PRM materials.

  15. [Measurement of Chemical Compounds in Indoor and Outdoor Air in Chiba City Using Diffusive Sampling Devices].

    PubMed

    Sakamoto, Hironari; Uchiyama, Shigehisa; Kihara, Akiko; Tsutake, Toyoshige; Bekki, Kanae; Inaba, Yohei; Nakagome, Hideki; Kunugita, Naoki

    2015-01-01

    Indoor air quality (IAQ) is a major concern, because people on average spend the vast majority of their time indoors and they are repeatedly exposed to indoor air pollutants. In this study, to assess indoor air quality in Chiba City, gaseous chemical compounds were surveyed using four types of diffusive sampler. Gaseous chemical compounds such as carbonyls, volatile organic compounds (VOC), acid gases, basic gases, and ozone were measured in indoor and outdoor air of 50 houses throughout Chiba City in winter and summer. Four types of diffusive sampler were used in this study: DSD-BPE/DNPH packed with 2,4-dinitrophenyl hydrazine and trans-1,2-bis(2-pyridyl)ethylene-coated silica for ozone and carbonyls; VOC-SD packed with Carboxen 564 particles for volatile organic compounds; DSD-TEA packed with triethanolamine-impregnated silica for acid gases; and DSD-NH3 packed with phosphoric acid-impregnated silica for basic gases. Almost all compounds in indoor air were detected at higher concentrations in summer than in winter. However, the nitrogen dioxide concentration in indoor air particularly increased only in winter, which well correlated with the formic acid concentration (correlation coefficient=0.974). The compound with the highest concentrations in indoor air was p-dichlorobenzene, with recorded levels of 13,000 μg m(-3) in summer and 1,100 μg m(-3) in winter in indoor air. p-Dichlorobenzene in summer and nitrogen dioxide in winter are detected at markedly high concentrations. Pollution control and continuous monitoring of IAQ are indispensable for human health.

  16. Environment and development of respiratory allergy. II. Indoors.

    PubMed

    D'Amato, G; Liccardi, G; D'Amato, M

    1994-12-01

    Even if it is difficult to obtain correct epidemiological evidence, there is a body of evidence which suggests that the frequency of allergic respiratory diseases is increasing. The majority of atopic patients, in particular in childhood and adolescence, develop immunoglobulin E (IgE) antibodies with clinical symptoms to aeroallergens, such as those derived from house dust mites, pollens and pets. Since, in the economically-developed countries individuals spend most of their time indoors (home, school and workplace), indoor pollutants (tobacco smoke etc.) and allergens (house dust mite, cats, etc.) are the most important source of exposure. Indoor allergens are associated with a wide variety of particles in a broad size range, only some of which are microscopically identifiable, culturable, or detectable with existing immunoassay. Evaluation of indoor allergens requires both air and source sampling, and several different analytical techniques. It is likely that the increased prevalence of allergy and asthma may be caused in the indoor environment by the synergistic action of air pollution (in particular derived from tobacco smoking) with allergic sensitization. Passive smoking in infancy has also been involved in the airways allergic sensitization to common aeroallergens.

  17. Diversity of indoor fungi as revealed by DNA metabarcoding.

    PubMed

    Korpelainen, Helena; Pietiläinen, Maria

    2017-01-01

    In the present study, we conducted DNA metabarcoding (the nuclear ITS2 region) for indoor fungal samples originating from two nursery schools with a suspected mould problem (sampling before and after renovation), from two university buildings, and from an old farmhouse. Good-quality sequences were obtained, and the results showed that DNA metabarcoding provides high resolution in fungal identification. The pooled proportions of sequences representing filamentous ascomycetes, filamentous basidiomycetes, yeasts, and other fungi equalled 62.3%, 8.0%, 28.3%, and 1.4%, respectively, and the total number of fungal genera found during the study was 585. When comparing fungal diversities and taxonomic composition between different types of buildings, no obvious pattern was detected. The average pairwise values of Sørensen Chao indices that were used to compare similarities for taxon composition between samples among the samples from the two university buildings, two nurseries, and farmhouse equaled 0.693, 0.736, 0.852, 0.928, and 0.981, respectively, while the mean similarity index for all samples was 0.864. We discovered that making explicit conclusions on the relationship between the indoor air quality and mycoflora is complicated by the lack of appropriate indicators for air quality and by the occurrence of wide spatial and temporal changes in diversity and compositions among samples.

  18. Post-feeding activity of Lucilia sericata (Diptera: Calliphoridae) on common domestic indoor surfaces and its effect on development.

    PubMed

    Robinson, L A; Bryson, D; Bulling, M T; Sparks, N; Wellard, K S

    2018-05-01

    Developmental data of forensically important blowflies used by entomologists to estimate minimum post mortem interval (mPMI) are established under controlled laboratory conditions for various temperature ranges throughout the stages of egg, 1st-3rd instar, puparia, and adult fly emergence. However, environmental conditions may influence the patterns of development and behaviour of blowflies, potentially impacting on these established development rates. Previous studies investigating indoor colonisation have focused on the delay to oviposition, with behaviour during the post-feeding phase in this setting often overlooked. The environment in which third instar larvae disperse when searching for a pupariation site may vary drastically at both outdoor and indoor scenarios, influencing the activity and distance travelled during this phase and possibly affecting developmental rates. This study investigated the effect of eight common domestic indoor surfaces on dispersal time, distance travelled, and behaviour of post-feeding Lucilia sericata as well as any resulting variation in development. It was found that pupariation and puparia length within a pupariation medium of sawdust (often used in laboratory settings) produced comparable results with that of carpeted environments (those deemed to be 'enclosed'). Non-carpeted environments (those which were 'exposed') produced a delay to pupariation likely due to increased activity and energy expenditure in searching for pupariation sites which enabled burial. In addition, the observed speed of travel during dispersal was seen via time lapse photography to be greater within 'exposed' conditions. Larvae which dispersed upon burnt laminate flooring were observed to travel faster than in all other conditions and showed the only significant variation (P=0.04) in the day of emergence in comparison to the control condition of sawdust. This study has demonstrated that wandering phase activity is affected by the environmental surface which has potential implications for estimating both the distance travelled by dispersing larvae in indoor conditions and with further research, may be a consideration in mPMI calculations. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. EMISSION OF ORGANIC SUBSTANCES FROM INDOOR SURFACE MATERIALS

    EPA Science Inventory

    A wide variety of surface materials in buildings can release organic compounds. Examples include building materials, furnishings, maintenance materials, clothing, and paper products. These sources contribute substantially to the hundreds of organic compounds that have been measur...

  20. Indoor Residential Chemical Exposures as Risk Factors for Asthmaand Allergy in Infants and Children: a Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendell, M.J.

    2006-03-01

    Most research into effects of residential indoor air exposures on asthma and allergies has focused on exposures to biologic allergens, moisture and mold, endotoxin, or combustion byproducts. This paper briefly reviews reported findings on associations of asthma or allergy in infants or children with risk factors related to indoor chemical emissions from residential materials or surface coatings. Associations, some strong (e.g., odds ratios up to 13), were reported. The most frequently identified risk factors were formaldehyde, aromatic organic compounds such as toluene and benzene, plastic materials and plasticizers, and recent painting. Exposures and consequent effects from indoor sources may bemore » exacerbated by decreased ventilation. Identified risk factors may be proxies for correlated exposures. Findings suggest the frequent occurrence of important but preventable effects on asthma and allergy in infants and children worldwide from modern residential building materials and coatings.« less

  1. Characterization of kerosene-heater emissions inside two mobile homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burton, R.M.; Seila, R.A.; Wilson, W.E.

    1990-03-01

    In an effort to determine the impact of kerosene heater emissions on indoor air quality, measurements were made in and around two mobile homes at a rural mobile home park near Apex, NC. The sampling was performed at two single-wide mobile homes equipped with kerosene heaters. The concentrations of acidic aerosols and gases, fine and coarse particulate aerosol mass, carbon monoxide, nitrogen oxides, volatile organic compounds and semivolatiles, were determined for periods of heater operation and for periods in which heaters were not operated. Simultaneous outdoor measurements of acid aerosols and gases, fine and coarse aerosol mass, and volatile organicmore » compounds were conducted to determine the contribution of outdoor pollutants to the indoor concentrations. Comparisons between the concentrations obtained from the analysis of outdoor, heater-on, and heater-off samples allowed the authors to examine the impacts of the kerosene emissions on indoor concentrations. Concentrations of sulfates, aerosol strong acidity, fine and coarse aerosol mass, carbon monoxide, and sulfur dioxide were found to be higher when the heater was operated; however, these heater-on concentrations were comparable to those observed in moderately polluted atmospheres. Indoor concentrations of nitrous acid and nitrogen oxides during heater operation were found to be considerably higher than those observed in polluted atmospheres. Finally, use of kerosene heaters was found to be responsible for increased concentrations of non-methane volatile and semi-volatile organic compounds indoors. Acid aerosol indoor concentrations were quite variable during the study and were found to exist in the presence of excess ammonia.« less

  2. Indoor aldehydes concentration and emission rate of formaldehyde in libraries and private reading rooms

    NASA Astrophysics Data System (ADS)

    Kim, Jeonghoon; Kim, Seojin; Lee, Kiyoung; Yoon, Dongwon; Lee, Jiryang; Ju, DaeYoung

    2013-06-01

    Aldehydes are of particularly interest due to their potential adverse impact on human health. Formaldehyde is one of the most abundant indoor pollutants. To improve indoor air quality, identifying and removing the major emission sources of formaldehyde would be desirable. The purposes of this study were to determine aldehyde concentrations in libraries and reading rooms and to identify emission sources of formaldehyde in private reading rooms. Indoor aldehyde concentrations were quantified at 66 facilities, including public libraries, children's libraries, public reading rooms, and private reading rooms, in the Seoul metropolitan area. Emission fluxes of formaldehyde from the surfaces of desks, chairs, floors, walls, and ceilings in 19 private reading rooms were measured using a passive emission colorimetric sensor. Indoor aldehyde (formaldehyde, acetaldehyde, propioaldehyde, benzaldehyde, and hexaldehyde) levels were significantly higher than outdoor levels. Indoor formaldehyde geometric mean concentrations in private reading rooms (119.3 μg m-3) were significantly higher than in public libraries (29.2 μg m-3), children's libraries (29.3 μg m-3), and public reading rooms (40.8 μg m-3). Indoor formaldehyde levels were associated with relative humidity. In private reading rooms, the emission rates from desks (255.5 ± 214.8 μg h-1) and walls (231.7 ± 192.3 μg h-1) were significantly higher than that from chairs (79.6 ± 88.5 μg h-1). Desks (31%) and walls (29%) were the major emission sources of formaldehyde in 14 facilities in which measurements exceeded the indoor standard of 100 μg m-3. The age of interior materials was a significant factor for indoor formaldehyde emission flux. Controlling the emission rates of desks and walls is recommended to improve formaldehyde concentrations in private reading rooms.

  3. Effects of Wintering Environment and Parasite–Pathogen Interactions on Honey Bee Colony Loss in North Temperate Regions

    PubMed Central

    Currie, Robert W.

    2016-01-01

    Extreme winter losses of honey bee colonies are a major threat to beekeeping but the combinations of factors underlying colony loss remain debatable. We monitored colonies in two environments (colonies wintered indoors or outdoors) and characterized the effects of two parasitic mites, seven viruses, and Nosema on honey bee colony mortality and population loss over winter. Samples were collected from two locations within hives in fall, mid-winter and spring of 2009/2010. Although fall parasite and pathogen loads were similar in outdoor and indoor-wintered colonies, the outdoor-wintered colonies had greater relative reductions in bee population score over winter. Seasonal patterns in deformed wing virus (DWV), black queen cell virus (BQCV), and Nosema level also differed with the wintering environment. DWV and Nosema levels decreased over winter for indoor-wintered colonies but BQCV did not. Both BQCV and Nosema concentration increased over winter in outdoor-wintered colonies. The mean abundance of Varroa decreased and concentration of Sacbrood virus (SBV), Kashmir bee virus (KBV), and Chronic bee paralysis virus (CBPV) increased over winter but seasonal patterns were not affected by wintering method. For most viruses, either entrance or brood area samples were reasonable predictors of colony virus load but there were significant season*sample location interactions for Nosema and BQCV, indicating that care must be taken when selecting samples from a single location. For Nosema spp., the fall entrance samples were better predictors of future infestation levels than were fall brood area samples. For indoor-wintered colonies, Israeli acute paralysis virus IAPV concentration was negatively correlated with spring population size. For outdoor-wintered hives, spring Varroa abundance and DWV concentration were positively correlated with bee loss and negatively correlated with spring population size. Multivariate analyses for fall collected samples indicated higher DWV was associated with colony death as did high SBV for spring-collected samples. PMID:27448049

  4. Cooking-related PM2.5 and acrolein measured in grocery stores and comparison with other retail types.

    PubMed

    Chan, W R; Sidheswaran, M; Sullivan, D P; Cohn, S; Fisk, W J

    2016-06-01

    We measured particulate matter (PM), acrolein, and other indoor air contaminants in eight visits to grocery stores in California. Retail stores of other types (hardware, furniture, and apparel) were also sampled on additional visits. Based on tracer gas decay data, most stores had adequate ventilation according to minimum ventilation rate standards. Grocery stores had significantly higher concentrations of acrolein, fine and ultrafine PM, compared to other retail stores, likely attributable to cooking. Indoor concentrations of PM2.5 and acrolein exceeded health guidelines in all tested grocery stores. Acrolein emission rates to indoors in grocery stores had a mean estimate about 30 times higher than in other retail store types. About 80% of the indoor PM2.5 measured in grocery stores was emitted indoors, compared to only 20% for the other retail store types. Calculations suggest a substantial increase in outdoor air ventilation rate by a factor of three from current level is needed to reduce indoor acrolein concentrations. Alternatively, acrolein emission to indoors needs to be reduced 70% by better capturing of cooking exhaust. To maintain indoor PM2.5 below the California annual ambient standard of 12 μg/m(3) , grocery stores need to use air filters with an efficiency rating higher than the MERV 8 air filters commonly used today. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Monitoring Indoor Air Quality for Enhanced Occupational Health.

    PubMed

    Pitarma, Rui; Marques, Gonçalo; Ferreira, Bárbara Roque

    2017-02-01

    Indoor environments are characterized by several pollutant sources. Because people spend more than 90% of their time in indoor environments, several studies have pointed out the impact of indoor air quality on the etiopathogenesis of a wide number of non-specific symptoms which characterizes the "Sick Building Syndrome", involving the skin, the upper and lower respiratory tract, the eyes and the nervous system, as well as many building related diseases. Thus, indoor air quality (IAQ) is recognized as an important factor to be controlled for the occupants' health and comfort. The majority of the monitoring systems presently available is very expensive and only allow to collect random samples. This work describes the system (iAQ), a low-cost indoor air quality monitoring wireless sensor network system, developed using Arduino, XBee modules and micro sensors, for storage and availability of monitoring data on a web portal in real time. Five micro sensors of environmental parameters (air temperature, humidity, carbon monoxide, carbon dioxide and luminosity) were used. Other sensors can be added for monitoring specific pollutants. The results reveal that the system can provide an effective indoor air quality assessment to prevent exposure risk. In fact, the indoor air quality may be extremely different compared to what is expected for a quality living environment. Systems like this would have benefit as public health interventions to reduce the burden of symptoms and diseases related to "sick buildings".

  6. Understanding interactions in the adsorption of gaseous organic compounds to indoor materials.

    PubMed

    Ongwandee, Maneerat; Chatsuvan, Thabtim; Suksawas Na Ayudhya, Wichitsawat; Morris, John

    2017-02-01

    We studied adsorption of organic compounds to a wide range of indoor materials, including plastics, gypsum board, carpet, and many others, under various relative humidity conditions by applying a conceptual model of the free energy of interfacial interactions of both van der Waals and Lewis acid-base (e-donor/acceptor) types. Data used for the analyses were partitioning coefficients of adsorbates between surface and gas phase obtained from three sources: our sorption experiments and two other published studies. Target organic compounds included apolars, monopolars, and bipolars. We established correlations of partitioning coefficients of adsorbates for a considered surface with the corresponding hexadecane/air partitioning coefficients of the adsorbates which are used as representative of a van der Waals descriptor instead of vapor pressure. The logarithmic adsorption coefficients of the apolars and weak bases, e.g., aliphatics and aromatics, to indoor materials linearly correlates well with the logarithmic hexadecane/air partitioning coefficients regardless of the surface polarity. The surface polarity in terms of e-donor/acceptor interactions becomes important for adsorption of the strong bases and bipolars, e.g., amines, phenols, and alcohols, to unpainted gypsum board. Under dry or humid conditions, the adsorption to flat plastic materials still linearly correlates well with the van der Waals interactions of the adsorbates, but no correlations were observed for the adsorption to fleecy or plush materials, e.g., carpet. Adsorption of highly bipolar compounds, e.g., phenol and isopropanol, is strongly affected by humidity, attributed to Lewis acid-base interactions with modified surfaces.

  7. Influence of architectural style on indoor radon concentration in a radon prone area: A case study.

    PubMed

    Baeza, A; García-Paniagua, J; Guillén, J; Montalbán, B

    2018-01-01

    Indoor radon is a major health concern as it is a known carcinogenic. Nowadays there is a trend towards a greater energy conservation in buildings, which is reflected in an increasing number of regulations. But, can this trend increase the indoor radon concentration? In this paper, we selected a radon prone area in Spain and focused on single-family dwellings constructed in a variety of architectural styles. These styles ranged from 1729 up to 2014, with varying construction techniques (from local resources to almost universally standard building materials) and regulations in force (from none to the Spanish regulation in force). The 226 Ra concentrations in soil and surface radon exhalation rates were rather similar in this area, mean values ranging 70-126Bq/kg and 49-100mBq/m 2 ·s, respectively. Indoor radon concentration was generally greater than the contribution from soil exhalation (surface exhalation rates), especially in New dwellings (1980-2014). Its concentration in dwellings built in the Traditional style (1729-1940) was significantly lower than in the new houses. This can be consequence of the air tightness of the dwellings as a consequence of the different regulations in force. In the period covered by the Traditional style, there was no regulation in force, and dwelling had loose air tight. Whereas in recent times, there are mandatory regulations assuring a better air tightness of the buildings. Refurbishment of Traditional dwellings also seems to increase the indoor radon concentration, as they must also comply with the regulations in force. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Exposure to major volatile organic compounds and carbonyls in European indoor environments and associated health risk.

    PubMed

    Sarigiannis, Dimosthenis A; Karakitsios, Spyros P; Gotti, Alberto; Liakos, Ioannis L; Katsoyiannis, Athanasios

    2011-05-01

    This paper summarizes recent data on the occurrence of major organic compounds (benzene, toluene, xylenes, styrene, acetaldehyde, formaldehyde, naphthalene, limonene, α-pinene and ammonia, classified by the European Commission's INDEX strategy report as the priority pollutants to be regulated) and evaluates accordingly cancer and non-cancer risks posed by indoor exposure in dwellings and public buildings in European Union (EU) countries. The review process indicated that significant differences in indoor air quality exist within and among the countries where data were available, indicating corresponding differences in sources and emission strength of airborne chemicals, identified or not. Conservative exposure limits were not exceeded for non-carcinogenic effects, except for formaldehyde; for carcinogenic agents the estimated risks were up to three orders of magnitude higher than the one (10(-6)) proposed as acceptable by risk management bodies. However, the risk assessment evaluation process faces crucial difficulties, either due to the relative paucity of indoor air quality measurements in many EU countries, or by the lack of sampling consistency in the already existing studies, indicating the need for additional measurements of indoor air quality following a harmonized sampling and analytical protocol. Additionally, uncertainties embodied in the cancer potency factors and exposure limit values impose further difficulties in substance prioritization and risk management. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Polycyclic Aromatic Hydrocarbons (PAHs) in Indoor Dusts of Guizhou, Southwest of China: Status, Sources and Potential Human Health Risk

    PubMed Central

    Li, Baizhan

    2015-01-01

    Polycyclic aromatic hydrocarbons (PAHs) were analyzed for 136 indoor dust samples collected from Guizhou province, southwest of China. The ∑18PAHs concentrations ranged from 2.18 μg•g-1 to 14.20 μg•g-1 with the mean value of 6.78 μg•g-1. The highest Σ18PAHs concentration was found in dust samples from orefields, followed by city, town and village. Moreover, the mean concentration of Σ18PAHs in indoor dust was at least 10% higher than that of outdoors. The 4–6 rings PAHs, contributing more than 70% of ∑18PAHs, were the dominant species. PAHs ratios, principal component analysis with multiple linear regression (PCA-MLR) and hierarchical clustering analysis (HCA) were applied to evaluate the possible sources. Two major origins of PAHs in indoor dust were identified as vehicle emissions and coal combustion. The mean incremental lifetime cancer risk (ILCR) due to human exposure to indoor dust PAHs in city, town, village and orefield of Guizhou province, China was 6.14×10−6, 5.00×10−6, 3.08×10−6, 6.02×10−6 for children and 5.92×10−6, 4.83×10−6, 2.97×10−6, 5.81×10−6 for adults, respectively. PMID:25719362

  10. Skin Cancer Risk Behaviors Among US Men: The Role of Sexual Orientation

    PubMed Central

    Safren, Steven A.

    2014-01-01

    The current study assessed skin cancer risk behaviors by sexual orientation in a nationally representative prospective sample of US men (n = 1767), sampled at ages 16 and 29 years. At age 16 years, sexual minority men were 3.9 times as likely as heterosexual men to indoor tan. Participants did not significantly differ in the use of sunscreen or the frequency of outdoor tanning. Thus, sexual minority men might be an at-risk group for developing skin cancers because of their indoor tanning behaviors. PMID:25033138

  11. Chlorine activation indoors and outdoors via surface-mediated reactions of nitrogen oxides with hydrogen chloride

    PubMed Central

    Raff, Jonathan D.; Njegic, Bosiljka; Chang, Wayne L.; Gordon, Mark S.; Dabdub, Donald; Gerber, R. Benny; Finlayson-Pitts, Barbara J.

    2009-01-01

    Gaseous HCl generated from a variety of sources is ubiquitous in both outdoor and indoor air. Oxides of nitrogen (NOy) are also globally distributed, because NO formed in combustion processes is oxidized to NO2, HNO3, N2O5 and a variety of other nitrogen oxides during transport. Deposition of HCl and NOy onto surfaces is commonly regarded as providing permanent removal mechanisms. However, we show here a new surface-mediated coupling of nitrogen oxide and halogen activation cycles in which uptake of gaseous NO2 or N2O5 on solid substrates generates adsorbed intermediates that react with HCl to generate gaseous nitrosyl chloride (ClNO) and nitryl chloride (ClNO2), respectively. These are potentially harmful gases that photolyze to form highly reactive chlorine atoms. The reactions are shown both experimentally and theoretically to be enhanced by water, a surprising result given the availability of competing hydrolysis reaction pathways. Airshed modeling incorporating HCl generated from sea salt shows that in coastal urban regions, this heterogeneous chemistry increases surface-level ozone, a criteria air pollutant, greenhouse gas and source of atmospheric oxidants. In addition, it may contribute to recently measured high levels of ClNO2 in the polluted coastal marine boundary layer. This work also suggests the potential for chlorine atom chemistry to occur indoors where significant concentrations of oxides of nitrogen and HCl coexist. PMID:19620710

  12. Design and Feasibility of a Text Messaging Intervention to Prevent Indoor Tanning Among Young Adult Women: A Pilot Study

    PubMed Central

    Mays, Darren

    2016-01-01

    Background Although skin cancer is largely preventable, it affects nearly 1 of 5 US adults. There is a need for research on how to optimally design persuasive public health indoor tanning prevention messages. Objective The objective of our study was to examine whether framed messages on indoor tanning behavioral intentions delivered through short message service (SMS) text messaging would produce (1) positive responses to the messages, including message receptivity and emotional response; (2) indoor tanning efficacy beliefs, including response efficacy and self-efficacy; and (3) indoor tanning risk beliefs. Methods We conducted a pilot study of indoor tanning prevention messages delivered via mobile phone text messaging in a sample of 21 young adult women who indoor tan. Participants completed baseline measures, were randomly assigned to receive gain-, loss-, or balanced-framed text messages, and completed postexposure outcome measures on indoor tanning cognitions and behaviors. Participants received daily mobile phone indoor tanning prevention text messages for 1 week and completed the same postexposure measures as at baseline. Results Over the 1-week period there were trends or significant changes after receipt of the text messages, including increased perceived susceptibility (P<.001), response efficacy beliefs (P<.001), and message receptivity (P=.03). Ordinary least squares stepwise linear regression models showed an effect of text message exposure on self-efficacy to quit indoor tanning (t6=–2.475, P<.02). Ordinary least squares linear regression including all measured scales showed a marginal effect of SMS texts on self-efficacy (t20=1.905, P=.08). Participants endorsed highly favorable views toward the text messaging protocol. Conclusions This study supports this use of mobile text messaging as an indoor tanning prevention strategy. Given the nature of skin cancer risk perceptions, the addition of multimedia messaging service is another area of potential innovation for disseminating indoor tanning prevention messages. PMID:28007691

  13. Design and Feasibility of a Text Messaging Intervention to Prevent Indoor Tanning Among Young Adult Women: A Pilot Study.

    PubMed

    Evans, William D; Mays, Darren

    2016-12-22

    Although skin cancer is largely preventable, it affects nearly 1 of 5 US adults. There is a need for research on how to optimally design persuasive public health indoor tanning prevention messages. The objective of our study was to examine whether framed messages on indoor tanning behavioral intentions delivered through short message service (SMS) text messaging would produce (1) positive responses to the messages, including message receptivity and emotional response; (2) indoor tanning efficacy beliefs, including response efficacy and self-efficacy; and (3) indoor tanning risk beliefs. We conducted a pilot study of indoor tanning prevention messages delivered via mobile phone text messaging in a sample of 21 young adult women who indoor tan. Participants completed baseline measures, were randomly assigned to receive gain-, loss-, or balanced-framed text messages, and completed postexposure outcome measures on indoor tanning cognitions and behaviors. Participants received daily mobile phone indoor tanning prevention text messages for 1 week and completed the same postexposure measures as at baseline. Over the 1-week period there were trends or significant changes after receipt of the text messages, including increased perceived susceptibility (P<.001), response efficacy beliefs (P<.001), and message receptivity (P=.03). Ordinary least squares stepwise linear regression models showed an effect of text message exposure on self-efficacy to quit indoor tanning (t 6 =-2.475, P<.02). Ordinary least squares linear regression including all measured scales showed a marginal effect of SMS texts on self-efficacy (t 20 =1.905, P=.08). Participants endorsed highly favorable views toward the text messaging protocol. This study supports this use of mobile text messaging as an indoor tanning prevention strategy. Given the nature of skin cancer risk perceptions, the addition of multimedia messaging service is another area of potential innovation for disseminating indoor tanning prevention messages. ©William Evans, Darren Mays. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 22.12.2016.

  14. Global air monitoring study: a multi-country comparison of levels of indoor air pollution in different workplaces.

    PubMed

    Koong, Heng Nung; Khoo, Deborah; Higbee, Cheryl; Travers, Mark; Hyland, Andrew; Cummings, K Michael; Dresler, Carolyn

    2009-03-01

    A local study completed in Singapore, which was part of an international multi-country study that aims to develop a global assessment of exposure to second-hand smoke in indoor workplaces, gathered data regarding the indoor air quality of public areas. It was hypothesised that air would be less polluted in non-smoking venues compared to places where smoking occurred. A TSI SidePak AM510 Personal Aerosol Monitor was used to sample and record the levels of respirable suspended particles (RSP) in the air. A broad range of venues were sampled in Singapore. The primary goal of data analysis was to assess the difference in the average levels of RSP in smoke-free and non smoke-free venues. Data was assessed at 3 levels: (a) the mean RSP across all venues sampled compared with the mean levels of smoke-free and non smoke-free venues, (b) levels in venues where smoking occurred compared with similar venues in Ireland, and (c) comparison between smoke-free and non smoke-free areas according to the type of venue. Statistical significance was assessed using the Mann-Whitney U-test. The level of indoor air pollution was 96% lower in smoke-free venues compared to non smoke-free venues. Averaged across each type of venue, the lowest levels of indoor air pollution were found in restaurants (17 microg/m3) and the highest in bars (622 microg/m3); both well above the US EPA Air Quality Index hazardous level of >or=251 ug/m3. This study demonstrates that workers and patrons are exposed to harmful levels of a known carcinogen and toxin. Policies that prohibit smoking in public areas dramatically reduce exposure and improve worker and patron health.

  15. [Effectiveness of the maintenance operations on the air conditioning systems of a university building in relation to the microbiological quality of the air indoor].

    PubMed

    De Filippis, Patrizia; Spinaci, Anna; Coia, Maura; Maggi, Oriana; Panà, Augusto

    2003-01-01

    The microbiological quality of the air indoor is influenced from various factors and one of the most important is represented from the maintenance of the conditioning systems. In this study it has been estimated the effectiveness of an intervention of cleaning and maintenance on the systems of conditioning of an university building executing sampling before and after such intervention. The two results were confronted and it is observed as the maintenance of the air conditioners has influenced on the quality of the air indoor.

  16. Modeling of indoor radon concentration from radon exhalation rates of building materials and validation through measurements.

    PubMed

    Kumar, Amit; Chauhan, R P; Joshi, Manish; Sahoo, B K

    2014-01-01

    Building materials are the second major source of indoor radon after soil. The contribution of building materials towards indoor radon depends upon the radium content and exhalation rates and can be used as a primary index for radon levels in the dwellings. The radon flux data from the building materials was used for calculation of the indoor radon concentrations and doses by many researchers using one and two dimensional model suggested by various researchers. In addition to radium content, the radon wall flux from a surface strongly depends upon the radon diffusion length (L) and thickness of the wall (2d). In the present work the indoor radon concentrations from the measured radon exhalation rate of building materials calculated using different models available in literature and validation of models was made through measurement. The variation in the predicted radon flux from different models was compared with d/L value for wall and roofs of different dwellings. The results showed that the radon concentrations predicted by models agree with experimental value. The applicability of different model with d/L ratio was discussed. The work aims to select a more appropriate and general model among available models in literature for the prediction of indoor radon. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. First characterization of the endocrine-disrupting potential of indoor gaseous and particulate contamination: comparison with urban outdoor air (France).

    PubMed

    Oziol, Lucie; Alliot, Fabrice; Botton, Jérémie; Bimbot, Maya; Huteau, Viviane; Levi, Yves; Chevreuil, Marc

    2017-01-01

    The composition of endocrine-disrupting compounds (EDCs) in the ambient air of indoor environments has already been described, but little is known about the inherent endocrine-disrupting potential of indoor air contamination. We therefore aimed to study the distribution of bioactive EDCs in the gaseous and particulate phases of indoor air using a cellular bioassay approach that integrates the interaction effects between chemicals. Organic air extracts, both gaseous and particulate, were taken from three indoor locations (office, apartment, and children's day care) in France and sampled in two different seasons in order to study their interference with the signaling of estrogen, androgen, and thyroid receptors. The experiments were also conducted on aerial extracts from an outdoor site (urban center). We found that gaseous and/or particulate extracts from all locations displayed estrogenicity, anti-androgenicity, and thyroidicity. Overall, indoor air extracts had a higher endocrine-disrupting potential compared to outdoor ones, especially during winter and in the day care. The biological activities were predominant for the gaseous extracts and tended to increase for the particulate extracts in cool conditions. In conclusion, our data confirmed the presence of bioactive EDCs in a gaseous state and highlighted their indoor origin and concentration, especially in the cold season.

  18. An updated review of case-control studies of lung cancer and indoor radon-Is indoor radon the risk factor for lung cancer?

    PubMed

    Sheen, Seungsoo; Lee, Keu Sung; Chung, Wou Young; Nam, Saeil; Kang, Dae Ryong

    2016-01-01

    Lung cancer is a leading cause of cancer-related death in the world. Smoking is definitely the most important risk factor for lung cancer. Radon ((222)Rn) is a natural gas produced from radium ((226)Ra) in the decay series of uranium ((238)U). Radon exposure is the second most common cause of lung cancer and the first risk factor for lung cancer in never-smokers. Case-control studies have provided epidemiological evidence of the causative relationship between indoor radon exposure and lung cancer. Twenty-four case-control study papers were found by our search strategy from the PubMed database. Among them, seven studies showed that indoor radon has a statistically significant association with lung cancer. The studies performed in radon-prone areas showed a more positive association between radon and lung cancer. Reviewed papers had inconsistent results on the dose-response relationship between indoor radon and lung cancer risk. Further refined case-control studies will be required to evaluate the relationship between radon and lung cancer. Sufficient study sample size, proper interview methods, valid and precise indoor radon measurement, wide range of indoor radon, and appropriate control of confounders such as smoking status should be considered in further case-control studies.

  19. Seasonal Variations of Indoor Microbial Exposures and Their Relation to Temperature, Relative Humidity, and Air Exchange Rate

    PubMed Central

    Bekö, Gabriel; Timm, Michael; Gustavsen, Sine; Hansen, Erik Wind

    2012-01-01

    Indoor microbial exposure has been related to adverse pulmonary health effects. Exposure assessment is not standardized, and various factors may affect the measured exposure. The aim of this study was to investigate the seasonal variation of selected microbial exposures and their associations with temperature, relative humidity, and air exchange rates in Danish homes. Airborne inhalable dust was sampled in five Danish homes throughout the four seasons of 1 year (indoors, n = 127; outdoors, n = 37). Measurements included culturable fungi and bacteria, endotoxin, N-acetyl-beta-d-glucosaminidase, total inflammatory potential, particles (0.75 to 15 μm), temperature, relative humidity, and air exchange rates. Significant seasonal variation was found for all indoor microbial exposures, excluding endotoxin. Indoor fungi peaked in summer (median, 235 CFU/m3) and were lowest in winter (median, 26 CFU/m3). Indoor bacteria peaked in spring (median, 2,165 CFU/m3) and were lowest in summer (median, 240 CFU/m3). Concentrations of fungi were predominately higher outdoors than indoors, whereas bacteria, endotoxin, and inhalable dust concentrations were highest indoors. Bacteria and endotoxin correlated with the mass of inhalable dust and number of particles. Temperature and air exchange rates were positively associated with fungi and N-acetyl-beta-d-glucosaminidase and negatively with bacteria and the total inflammatory potential. Although temperature, relative humidity, and air exchange rates were significantly associated with several indoor microbial exposures, they could not fully explain the observed seasonal variations when tested in a mixed statistical model. In conclusion, the season significantly affects indoor microbial exposures, which are influenced by temperature, relative humidity, and air exchange rates. PMID:23001651

  20. Human Occupancy as a Source of Indoor Airborne Bacteria

    PubMed Central

    Hospodsky, Denina; Qian, Jing; Nazaroff, William W.; Yamamoto, Naomichi; Bibby, Kyle; Rismani-Yazdi, Hamid; Peccia, Jordan

    2012-01-01

    Exposure to specific airborne bacteria indoors is linked to infectious and noninfectious adverse health outcomes. However, the sources and origins of bacteria suspended in indoor air are not well understood. This study presents evidence for elevated concentrations of indoor airborne bacteria due to human occupancy, and investigates the sources of these bacteria. Samples were collected in a university classroom while occupied and when vacant. The total particle mass concentration, bacterial genome concentration, and bacterial phylogenetic populations were characterized in indoor, outdoor, and ventilation duct supply air, as well as in the dust of ventilation system filters and in floor dust. Occupancy increased the total aerosol mass and bacterial genome concentration in indoor air PM10 and PM2.5 size fractions, with an increase of nearly two orders of magnitude in airborne bacterial genome concentration in PM10. On a per mass basis, floor dust was enriched in bacterial genomes compared to airborne particles. Quantitative comparisons between bacterial populations in indoor air and potential sources suggest that resuspended floor dust is an important contributor to bacterial aerosol populations during occupancy. Experiments that controlled for resuspension from the floor implies that direct human shedding may also significantly impact the concentration of indoor airborne particles. The high content of bacteria specific to the skin, nostrils, and hair of humans found in indoor air and in floor dust indicates that floors are an important reservoir of human-associated bacteria, and that the direct particle shedding of desquamated skin cells and their subsequent resuspension strongly influenced the airborne bacteria population structure in this human-occupied environment. Inhalation exposure to microbes shed by other current or previous human occupants may occur in communal indoor environments. PMID:22529946

  1. Monitoring Malaria Vector Control Interventions: Effectiveness of Five Different Adult Mosquito Sampling Methods

    PubMed Central

    Onyango, Shirley A.; Kitron, Uriel; Mungai, Peter; Muchiri, Eric M.; Kokwaro, Elizabeth; King, Charles H.; Mutuku, Francis M.

    2014-01-01

    Long-term success of ongoing malaria control efforts based on mosquito bed nets (long-lasting insecticidal net) and indoor residual spraying is dependent on continuous monitoring of mosquito vectors, and thus on effective mosquito sampling tools. The objective of our study was to identify the most efficient mosquito sampling tool(s) for routine vector surveillance for malaria and lymphatic filariasis transmission in coastal Kenya. We evaluated relative efficacy of five collection methods—light traps associated with a person sleeping under a net, pyrethrum spray catches, Prokopack aspirator, clay pots, and urine-baited traps—in four villages representing three ecological settings along the south coast of Kenya. Of the five methods, light traps were the most efficient for collecting female Anopheles gambiae s.l. (Giles) (Diptera: Culicidae) and Anopheles funestus (Giles) (Diptera: Culicidae) mosquitoes, whereas the Prokopack aspirator was most efficient in collecting Culex quinquefasciatus (Say) (Diptera: Culicidae) and other culicines. With the low vector densities here, and across much of sub-Saharan Africa, wherever malaria interventions, long-lasting insecticidal nets, and/or indoor residual spraying are in place, the use of a single mosquito collection method will not be sufficient to achieve a representative sample of mosquito population structure. Light traps will remain a relevant tool for host-seeking mosquitoes, especially in the absence of human landing catches. For a fair representation of the indoor mosquito population, light traps will have to be supplemented with aspirator use, which has potential for routine monitoring of indoor resting mosquitoes, and can substitute the more labor-intensive and intrusive pyrethrum spray catches. There are still no sufficiently efficient mosquito collection methods for sampling outdoor mosquitoes, particularly those that are bloodfed. PMID:24180120

  2. Specular reflectance of soiled glass mirrors - Study on the impact of incidence angles

    NASA Astrophysics Data System (ADS)

    Heimsath, Anna; Lindner, Philip; Klimm, Elisabeth; Schmid, Tobias; Moreno, Karolina Ordonez; Elon, Yehonatan; Am-Shallem, Morag; Nitz, Peter

    2016-05-01

    The accumulation of dust and soil on the surface of solar reflectors is an important factor reducing the power output of solar power plants. Therefore the effect of accumulated dust on the specular reflectance of solar mirrors should be understood well in order to improve the site-dependent performance prediction. Furthermore, an optimization of the CSP System maintenance, in particular the cleaning cycles, can be achieved. Our measurements show a noticeable decrease of specular reflectance when the angle of incidence is increased. This effect may be explained by shading and blocking mechanisms caused by dirt particles. The main physical causes of radiation loss being absorption and scattering, the near-angle scattering leads to a further decrease of specular reflectance for smaller angles of acceptance. Within this study mirror samples were both outdoor exposed and indoor artificially soiled. For indoor soiling, the mirror samples were artificially soiled in an in-house developed dusting device using both artificial-standardized dust and real dust collected from an arid outdoor test field at the Negev desert. A model function is proposed that approximates the observed reduction of specular reflectance with the incidence angle with a sufficient accuracy and by simple means for this soil type. Hence a first step towards a new approach to improve site dependent performance prediction of solar power plants is taken.

  3. Automatic Construction of Wi-Fi Radio Map Using Smartphones

    NASA Astrophysics Data System (ADS)

    Liu, Tao; Li, Qingquan; Zhang, Xing

    2016-06-01

    Indoor positioning could provide interesting services and applications. As one of the most popular indoor positioning methods, location fingerprinting determines the location of mobile users by matching the received signal strength (RSS) which is location dependent. However, fingerprinting-based indoor positioning requires calibration and updating of the fingerprints which is labor-intensive and time-consuming. In this paper, we propose a visual-based approach for the construction of radio map for anonymous indoor environments without any prior knowledge. This approach collects multi-sensors data, e.g. video, accelerometer, gyroscope, Wi-Fi signals, etc., when people (with smartphones) walks freely in indoor environments. Then, it uses the multi-sensor data to restore the trajectories of people based on an integrated structure from motion (SFM) and image matching method, and finally estimates location of sampling points on the trajectories and construct Wi-Fi radio map. Experiment results show that the average location error of the fingerprints is about 0.53 m.

  4. Detection of indoor biological hazards using the man-portable laser induced breakdown spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Munson, Chase A.; Gottfried, Jennifer L.; Snyder, Emily Gibb

    2008-11-01

    The performance of a man-portable laser induced breakdown spectrometer was evaluated for the detection of biological powders on indoor office surfaces and wipe materials. Identification of pure unknown powders was performed by comparing against a library of spectra containing biological agent surrogates and confusant materials, such as dusts, diesel soot, natural and artificial sweeteners, and drink powders, using linear correlation analysis. Simple models constructed using a second technique, partial least squares discriminant analysis, successfully identified Bacillus subtilis (BG) spores on wipe materials and office surfaces. Furthermore, these models were able to identify BG on materials not used in the trainingmore » of the model.« less

  5. Collaborative Indoor Access Point Localization Using Autonomous Mobile Robot Swarm.

    PubMed

    Awad, Fahed; Naserllah, Muhammad; Omar, Ammar; Abu-Hantash, Alaa; Al-Taj, Abrar

    2018-01-31

    Localization of access points has become an important research problem due to the wide range of applications it addresses such as dismantling critical security threats caused by rogue access points or optimizing wireless coverage of access points within a service area. Existing proposed solutions have mostly relied on theoretical hypotheses or computer simulation to demonstrate the efficiency of their methods. The techniques that rely on estimating the distance using samples of the received signal strength usually assume prior knowledge of the signal propagation characteristics of the indoor environment in hand and tend to take a relatively large number of uniformly distributed random samples. This paper presents an efficient and practical collaborative approach to detect the location of an access point in an indoor environment without any prior knowledge of the environment. The proposed approach comprises a swarm of wirelessly connected mobile robots that collaboratively and autonomously collect a relatively small number of non-uniformly distributed random samples of the access point's received signal strength. These samples are used to efficiently and accurately estimate the location of the access point. The experimental testing verified that the proposed approach can identify the location of the access point in an accurate and efficient manner.

  6. Collaborative Indoor Access Point Localization Using Autonomous Mobile Robot Swarm

    PubMed Central

    Awad, Fahed; Naserllah, Muhammad; Omar, Ammar; Abu-Hantash, Alaa; Al-Taj, Abrar

    2018-01-01

    Localization of access points has become an important research problem due to the wide range of applications it addresses such as dismantling critical security threats caused by rogue access points or optimizing wireless coverage of access points within a service area. Existing proposed solutions have mostly relied on theoretical hypotheses or computer simulation to demonstrate the efficiency of their methods. The techniques that rely on estimating the distance using samples of the received signal strength usually assume prior knowledge of the signal propagation characteristics of the indoor environment in hand and tend to take a relatively large number of uniformly distributed random samples. This paper presents an efficient and practical collaborative approach to detect the location of an access point in an indoor environment without any prior knowledge of the environment. The proposed approach comprises a swarm of wirelessly connected mobile robots that collaboratively and autonomously collect a relatively small number of non-uniformly distributed random samples of the access point’s received signal strength. These samples are used to efficiently and accurately estimate the location of the access point. The experimental testing verified that the proposed approach can identify the location of the access point in an accurate and efficient manner. PMID:29385042

  7. Microbiological quality of indoor air in university libraries.

    PubMed

    Hayleeyesus, Samuel Fekadu; Manaye, Abayneh Melaku

    2014-05-01

    To evaluate the concentration of bacteria and fungi in the indoor environment of Jimma University libraries, so as to estimate the health hazard and to create standards for indoor air quality control. The microbial quality of indoor air of eight libraries of Jimma University was determined. The settle plate method using open Petri-dishes containing different culture media was employed to collect sample twice daily. Isolates were identified according to standard methods. The concentrations of bacteria and fungi aerosols in the indoor environment of the university libraries ranged between 367-2595 CFU/m(3). According to the sanitary standards classification of European Commission, almost all the libraries indoor air of Jimma University was heavily contaminated with bacteria and fungi. In spite of their major source difference, the average fungi density found in the indoor air of libraries did appear to follow the same trend with bacterial density (P=0.001). The bacteria isolates included Micrococcus sp., Staphylococcus aureus, Streptococcus pyogenes, Bacillus sp. and Neisseria sp. while Cladosporium sp., Alternaria sp., Penicillium sp. and Aspergillus sp. were the most isolated fungi. The indoor air of all libraries were in the range above highly contaminated according to European Commission classification and the most isolates are considered as potential candidates involved in the establishment of sick building syndromes and often associated with clinical manifestations like allergy, rhinitis, asthma and conjunctivitis. Thus, attention must be given to control those environmental factors which favor the growth and multiplication of microbes in indoor environment of libraries to safeguard the health of users and workers.

  8. Indoor air quality in homes, offices and restaurants in Korean urban areas—indoor/outdoor relationships

    NASA Astrophysics Data System (ADS)

    Baek, Sung-Ok; Kim, Yoon-Shin; Perry, Roger

    Air quality monitoring was carried out to collect data on the levels of various indoor and ambient air constituents in two cities in Korea (Seoul and Taegu). Sampling was conducted simultaneously indoors and outdoors at six residences, six offices and six restaurants in each city during summer 1994 and winter 1994-1995. Measured pollutants were respirable suspended particulate matter (RSP), carbon monoxide (CO), carbon dioxide (CO 2), nitrogen dioxide (NO 2), and a range of volatile organic compounds (VOCs). In addition, in order to evaluate the effect of smoking on indoor air quality, analyses of parameters associated with environmental tobacco smoke (ETS) were undertaken, which are nicotine, ultraviolet (UVPM), fluorescence (FPM) and solanesol particulate matter (SolPM). The results of this study have confirmed the importance of ambient air in determining the quality of air indoors in two major Korean cities. The majority of VOCs measured in both indoor and outdoor environments were derived from outdoor sources, probably motor vehicles. Benzene and other VOC concentrations were much higher during the winter months than the summer months and were not significantly greater in the smoking sites examined. Heating and cooking practices, coupled with generally inadequate ventilation, also were shown to influence indoor air quality. In smoking sites, ETS appears to be a minor contributor to VOC levels as no statistically significant relationships were identified with ETS components and VOCs, whereas very strong correlations were found between indoor and outdoor levels of vehicle-related pollutants. The average contribution of ETS to total RSP concentrations was estimated to range from 10 to 20%.

  9. Current implications of past DDT indoor spraying in Oman.

    PubMed

    Booij, Petra; Holoubek, Ivan; Klánová, Jana; Kohoutek, Jiří; Dvorská, Alice; Magulová, Katarína; Al-Zadjali, Said; Čupr, Pavel

    2016-04-15

    In Oman, DDT was sprayed indoors during an intensive malaria eradication program between 1976 and 1992. DDT can remain for years after spraying and is associated with potential health risk. This raises the concern for human exposure in areas where DDT was used for indoor spraying. Twelve houses in three regions with a different history of DDT indoor spraying were chosen for a sampling campaign in 2005 to determine p,p'-dichlorodiphenyltrichloroethane (p,p'-DDT), p,p'-dichlorodiphenyldichloroethylene (p,p'-DDE) and p,p'-dichlorodiphenyldichloroethane (p,p'-DDD) levels in indoor air, dust, and outdoor soil. Although DDT was only sprayed indoor, p,p'-DDT, p,p'-DDE and p,p'-DDD were also found in outdoor soil. The results indicate that release and exposure continue for years after cessation of spraying. The predicted cancer risk based on concentrations determined in 2005, indicate that there was still a significant cancer risk up to 13 to 16years after indoor DDT spraying. A novel approach, based on region-specific half-lives, was used to predict concentrations in 2015 and showed that more than 21years after spraying, cancer risk for exposure to indoor air, dust, and outdoor soil are acceptable in Oman for adults and young children. The model can be used for other locations and countries to predict prospective exposure of contaminants based on indoor experimental measurements and knowledge about the spraying time-schedule to extrapolate region-specific half-lives and predict effects on the human population years after spraying. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Spatial and temporal variations in indoor environmental conditions, human occupancy, and operational characteristics in a new hospital building

    DOE PAGES

    Ramos, Tiffanie; Dedesko, Sandra; Siegel, Jeffrey A.; ...

    2015-03-02

    The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogatemore » measures for human occupancy and activity in the patient rooms using both indoor air CO₂ concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ~8×10⁶ data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.« less

  11. Spatial and Temporal Variations in Indoor Environmental Conditions, Human Occupancy, and Operational Characteristics in a New Hospital Building

    PubMed Central

    Ramos, Tiffanie; Dedesko, Sandra; Siegel, Jeffrey A.; Gilbert, Jack A.; Stephens, Brent

    2015-01-01

    The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogate measures for human occupancy and activity in the patient rooms using both indoor air CO2 concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ∼8×106 data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections. PMID:25729898

  12. Sources of variation for indoor nitrogen dioxide in rural residences of Ethiopia

    PubMed Central

    2009-01-01

    Background Unprocessed biomass fuel is the primary source of indoor air pollution (IAP) in developing countries. The use of biomass fuel has been linked with acute respiratory infections. This study assesses sources of variations associated with the level of indoor nitrogen dioxide (NO2). Materials and methods This study examines household factors affecting the level of indoor pollution by measuring NO2. Repeated measurements of NO2 were made using a passive diffusive sampler. A Saltzman colorimetric method using a spectrometer calibrated at 540 nm was employed to analyze the mass of NO2 on the collection filter that was then subjected to a mass transfer equation to calculate the level of NO2 for the 24 hours of sampling duration. Structured questionnaire was used to collect data on fuel use characteristics. Data entry and cleaning was done in EPI INFO version 6.04, while data was analyzed using SPSS version 15.0. Analysis of variance, multiple linear regression and linear mixed model were used to isolate determining factors contributing to the variation of NO2 concentration. Results A total of 17,215 air samples were fully analyzed during the study period. Wood and crop were principal source of household energy. Biomass fuel characteristics were strongly related to indoor NO2 concentration in one-way analysis of variance. There was variation in repeated measurements of indoor NO2 over time. In a linear mixed model regression analysis, highland setting, wet season, cooking, use of fire events at least twice a day, frequency of cooked food items, and interaction between ecology and season were predictors of indoor NO2 concentration. The volume of the housing unit and the presence of kitchen showed little relevance in the level of NO2 concentration. Conclusion Agro-ecology, season, purpose of fire events, frequency of fire activities, frequency of cooking and physical conditions of housing are predictors of NO2 concentration. Improved kitchen conditions and ventilation are highly recommended. PMID:19922645

  13. Indoor air quality in public buildings. Volume 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheldon, L.; Zelon, H.; Sickles, J.

    Two separate but closely related studies of exposures to volatile organic compounds (VOCs) in buildings where people spend long periods of time were conducted. This report summarizes results obtained in six buildings: a new hospital, office and nursing home and another office, office/school, and nursing home. At each building sampling was performed at three indoor locations and a single outdoor location.

  14. Toxicity of airborne dust as an indicator of moisture problems in school buildings.

    PubMed

    Tirkkonen, Jenni; Täubel, Martin; Leppänen, Hanna; Peltonen, Matti; Lindsley, William; Chen, Bean T; Hyvärinen, Anne; Hirvonen, Maija-Riitta; Huttunen, Kati

    2017-02-01

    Moisture-damaged indoor environments are thought to increase the toxicity of indoor air particulate matter (PM), indicating that a toxicological assay could be used as a method for recognizing buildings with indoor air problems. We aimed to test if our approach of analyzing the toxicity of actively collected indoor air PM in vitro differentiates moisture-damaged from non-damaged school buildings. We collected active air samples with NIOSH Bioaerosol Cyclone Samplers from moisture-damaged (index) and non-damaged (reference) school buildings (4 + 4). The teachers and pupils of the schools were administered a symptom questionnaire. Five samples of two size fractions [Stage 1 (>1.9 μm) and Stage 2 (1-1.9 μm)] were collected from each school. Mouse RAW264.7 macrophages were exposed to the collected PM for 24 h and subsequently analyzed for changes in cell metabolic activity, production of nitric oxide (NO), tumor necrosis factor (TNF)-α and interleukin (IL)-6. The teachers working in the moisture-damaged schools reported respiratory symptoms such as cough (p = 0.01) and shortness of breath (p = 0.01) more often than teachers from reference schools. Toxicity of the PM sample as such did not differentiate index from reference building,s but the toxicity adjusted for the amount of the particles tended to be higher in moisture-damaged schools. Further development of the method will require identification of other confounding factors in addition to the necessity to adjust for differences in particle counts between samples.

  15. Exposure to PM2.5 in modern office buildings through elemental characterization and oxidative potential

    NASA Astrophysics Data System (ADS)

    Szigeti, Tamás; Kertész, Zsófia; Dunster, Christina; Kelly, Frank J.; Záray, Gyula; Mihucz, Victor G.

    2014-09-01

    Fifty samples of indoor and outdoor PM2.5 were collected onto quartz fiber and Teflon membrane filters in five office buildings equipped with heating, ventilation and air-conditioning system for 8 h daily in order to coincide with the work shift of employees. Samples were analyzed for i) mass concentration; ii) elemental concentration; and iii) oxidative potential (OP) through antioxidant depletion. The PM2.5 mass concentration exceeded the annual mean guideline of 10 μg m-3 WHO in 50% of the samples. Indoor and outdoor PM2.5 mass concentrations correlated almost linearly. Proton-induced X-ray emission (PIXE) spectrometry was used for the monitoring of 21 elements. Quantitative determination was achieved in the case of Teflon filters only for Al, Si, S, Cl, K, Ca, Ti, Cr, Mn, Fe and Zn at ng m-3 concentration level. Quartz fiber filters were less adequate for the PIXE measurements due to their greater thickness and filamentary structure. Ca, Cr, Zn and Ti had generally higher concentration (mg g-1) indoors. Indoor/outdoor (I/O) OP values were higher than one in 14% and 57% of the samples in the case of ascorbate and reduced glutathione (GSH), respectively. Spatial and temporal variations of OP were observed across the office buildings. The I/O ratios for OP, Cr and Zn concentrations in the case of GSH were higher for three buildings. Significant relationship was observed between GSH oxidation and Cr and Zn concentrations. Thus, employees were exposed to a higher extent to reactive oxygen species in three buildings.

  16. Detection of airborne Stachybotrys chartarum macrocyclic trichothecene mycotoxins in the indoor environment.

    PubMed

    Brasel, T L; Martin, J M; Carriker, C G; Wilson, S C; Straus, D C

    2005-11-01

    The existence of airborne mycotoxins in mold-contaminated buildings has long been hypothesized to be a potential occupant health risk. However, little work has been done to demonstrate the presence of these compounds in such environments. The presence of airborne macrocyclic trichothecene mycotoxins in indoor environments with known Stachybotrys chartarum contamination was therefore investigated. In seven buildings, air was collected using a high-volume liquid impaction bioaerosol sampler (SpinCon PAS 450-10) under static or disturbed conditions. An additional building was sampled using an Andersen GPS-1 PUF sampler modified to separate and collect particulates smaller than conidia. Four control buildings (i.e., no detectable S. chartarum growth or history of water damage) and outdoor air were also tested. Samples were analyzed using a macrocyclic trichothecene-specific enzyme-linked immunosorbent assay (ELISA). ELISA specificity was tested using phosphate-buffered saline extracts of the fungal genera Aspergillus, Chaetomium, Cladosporium, Fusarium, Memnoniella, Penicillium, Rhizopus, and Trichoderma, five Stachybotrys strains, and the indoor air allergens Can f 1, Der p 1, and Fel d 1. For test buildings, the results showed that detectable toxin concentrations increased with the sampling time and short periods of air disturbance. Trichothecene values ranged from <10 to >1,300 pg/m3 of sampled air. The control environments demonstrated statistically significantly (P < 0.001) lower levels of airborne trichothecenes. ELISA specificity experiments demonstrated a high specificity for the trichothecene-producing strain of S. chartarum. Our data indicate that airborne macrocyclic trichothecenes can exist in Stachybotrys-contaminated buildings, and this should be taken into consideration in future indoor air quality investigations.

  17. Development and performance assessment of a luminex xMAP® direct hybridization assay for the detection and identification of indoor air fungal contamination.

    PubMed

    Libert, Xavier; Packeu, Ann; Bureau, Fabrice; Roosens, Nancy H; De Keersmaecker, Sigrid C J

    2017-01-01

    Considered as a public health problem, indoor fungal contamination is generally monitored using classical protocols based on culturing. However, this culture dependency could influence the representativeness of the fungal population detected in an analyzed sample as this includes the dead and uncultivable fraction. Moreover, culture-based protocols are often time-consuming. In this context, molecular tools are a powerful alternative, especially those allowing multiplexing. In this study a Luminex xMAP® assay was developed for the simultaneous detection of 10 fungal species which are most frequently in indoor air and that may cause health problems. This xMAP® assay was found to be sensitive, i.e. its limit of detection is ranging between 0.05 and 0.01 ng of gDNA. The assay was subsequently tested with environmental air samples which were also analyzed with a classical protocol. All the species identified with the classical method were also detected with the xMAP® assay, however in a shorter time frame. These results demonstrate that the Luminex xMAP® fungal assay developed in this study could contribute to the improvement of public health and specifically to the indoor fungal contamination treatment.

  18. Calibration of two passive air samplers for monitoring phthalates and brominated flame-retardants in indoor air.

    PubMed

    Saini, Amandeep; Okeme, Joseph O; Goosey, Emma; Diamond, Miriam L

    2015-10-01

    Two passive air samplers (PAS), polyurethane foam (PUF) disks and Sorbent Impregnated PUF (SIP) disks, were characterized for uptake of phthalates and brominated flame-retardants (BFRs) indoors using fully and partially sheltered housings. Based on calibration against an active low-volume air sampler for gas- and particle-phase compounds, we recommend generic sampling rates of 3.5±0.9 and 1.0±0.4 m(3)/day for partially and fully sheltered housing, respectively, which applies to gas-phase phthalates and BFRs as well as particle-phase DEHP (the later for the partially sheltered PAS). For phthalates, partially sheltered SIPs are recommended. Further, we recommend the use of partially sheltered PAS indoors and a deployment period of one month. The sampling rate for the partially sheltered PUF and SIP of 3.5±0.9 m(3)/day is indistinguishable from that reported for fully sheltered PAS deployed outdoors, indicating the role of the housing outdoors to minimize the effect of variable wind velocities on chemical uptake, versus the partially sheltered PAS deployed indoors to maximize chemical uptake where air flow rates are low. Copyright © 2015. Published by Elsevier Ltd.

  19. Seasonal and diurnal variability in airborne mold from an indoor residential environment in northern New York.

    PubMed

    LeBouf, Ryan; Yesse, Liesel; Rossner, Alan

    2008-05-01

    It is well known that characterization of airborne bioaerosols in indoor environments is a challenge because of inherent irregularity in concentrations, which are influenced by many environmental factors. The primary aim of this study was to quantify the day-to-day variability of airborne fungal levels in a single residential environment over multiple seasons. Indoor air quality practitioners must recognize the inherent variability in airborne bio-aerosol measurements during data analysis of mold investigations. Changes in airborne fungi due to varying season and day is important to recognize when considering health impacts of these contaminants and when establishing effective controls. Using an Andersen N6 impactor, indoor and outdoor bioaerosol samples were collected on malt extract agar plates for 18 weekdays and 19 weekdays in winter and summer, respectively. Interday and intraday variability for the bioaerosols were determined for each sampler. Average fungal concentrations were 26 times higher during the summer months. Day-to-day fungal samples showed a relatively high inconsistency suggesting airborne fungal levels are very episodic and are influenced by several environmental factors. Summer bio-aerosol variability ranged from 7 to 36% and winter variability from 24 to 212%; these should be incorporated into results of indoor mold investigations. The second objective was to observe the relationship between biological and nonbiological particulate matter (PM). No correlation was observed between biological and nonbiological PM. Six side-by-side particulate samplers collected coarse PM (PM10) and fine PM (PM2.5) levels in both seasons. PM2.5 particulate concentrations were found to be statistically higher during summer months. Interday variability observed during this study suggests that indoor air quality practitioners must adjust their exposure assessment strategies to reflect the temporal variability in bioaerosol concentrations.

  20. Application of the maximum cumulative ratio (MCR) as a screening tool for the evaluation of mixtures in residential indoor air.

    PubMed

    De Brouwere, Katleen; Cornelis, Christa; Arvanitis, Athanasios; Brown, Terry; Crump, Derrick; Harrison, Paul; Jantunen, Matti; Price, Paul; Torfs, Rudi

    2014-05-01

    The maximum cumulative ratio (MCR) method allows the categorisation of mixtures according to whether the mixture is of concern for toxicity and if so whether this is driven by one substance or multiple substances. The aim of the present study was to explore, by application of the MCR approach, whether health risks due to indoor air pollution are dominated by one substance or are due to concurrent exposure to various substances. Analysis was undertaken on monitoring data of four European indoor studies (giving five datasets), involving 1800 records of indoor air or personal exposure. Application of the MCR methodology requires knowledge of the concentrations of chemicals in a mixture together with health-based reference values for those chemicals. For this evaluation, single substance health-based reference values (RVs) were selected through a structured review process. The MCR analysis found high variability in the proportion of samples of concern for mixture toxicity. The fraction of samples in these groups of concern varied from 2% (Flemish schools) to 77% (EXPOLIS, Basel, indoor), the variation being due not only to the variation in indoor air contaminant levels across the studies but also to other factors such as differences in number and type of substances monitored, analytical performance, and choice of RVs. However, in 4 out of the 5 datasets, a considerable proportion of cases were found where a chemical-by-chemical approach failed to identify the need for the investigation of combined risk assessment. Although the MCR methodology applied in the current study provides no consideration of commonality of endpoints, it provides a tool for discrimination between those mixtures requiring further combined risk assessment and those for which a single-substance assessment is sufficient. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Evaluating environmental modeling and sampling data with biomarker data to identify sources and routes of exposure

    NASA Astrophysics Data System (ADS)

    Shin, Hyeong-Moo; McKone, Thomas E.; Bennett, Deborah H.

    2013-04-01

    Exposure to environmental chemicals results from multiple sources, environmental media, and exposure routes. Ideally, modeled exposures should be compared to biomonitoring data. This study compares the magnitude and variation of modeled polycyclic aromatic hydrocarbons (PAHs) exposures resulting from emissions to outdoor and indoor air and estimated exposure inferred from biomarker levels. Outdoor emissions result in both inhalation and food-based exposures. We modeled PAH intake doses using U.S. EPA's 2002 National Air Toxics Assessment (NATA) county-level emissions data for outdoor inhalation, the CalTOX model for food ingestion (based on NATA emissions), and indoor air concentrations from field studies for indoor inhalation. We then compared the modeled intake with the measured urine levels of hydroxy-PAH metabolites from the 2001-2002 National Health and Nutrition Examination Survey (NHANES) survey as quantifiable human intake of PAH parent-compounds. Lognormal probability plots of modeled intakes and estimated intakes inferred from biomarkers suggest that a primary route of exposure to naphthalene, fluorene, and phenanthrene for the U.S. population is likely inhalation from indoor sources. For benzo(a)pyrene, the predominant exposure route is likely from food ingestion resulting from multi-pathway transport and bioaccumulation due to outdoor emissions. Multiple routes of exposure are important for pyrene. We also considered the sensitivity of the predicted exposure to the proportion of the total naphthalene production volume emitted to the indoor environment. The comparison of PAH biomarkers with exposure variability estimated from models and sample data for various exposure pathways supports that both indoor and outdoor models are needed to capture the sources and routes of exposure to environmental contaminants.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramos, Tiffanie; Dedesko, Sandra; Siegel, Jeffrey A.

    The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogatemore » measures for human occupancy and activity in the patient rooms using both indoor air CO₂ concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ~8×10⁶ data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.« less

  3. Semivolatile Organic Compounds in Homes: Strategies for Efficient and Systematic Exposure Measurement Based on Empirical and Theoretical Factors

    PubMed Central

    2014-01-01

    Residential exposure can dominate total exposure for commercial chemicals of health concern; however, despite the importance of consumer exposures, methods for estimating household exposures remain limited. We collected house dust and indoor air samples in 49 California homes and analyzed for 76 semivolatile organic compounds (SVOCs)—phthalates, polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), and pesticides. Sixty chemicals were detected in either dust or air and here we report 58 SVOCs detected in dust for the first time. In dust, phthalates (bis(2-ethylhexyl) phthalate, benzyl butyl phthalate, di-n-butyl phthalate) and flame retardants (PBDE 99, PBDE 47) were detected at the highest concentrations relative to other chemicals at the 95th percentile, while phthalates were highest at the median. Because SVOCs are found in both gas and condensed phases and redistribute from their original source over time, partitioning models can clarify their fate indoors. We use empirical data to validate air-dust partitioning models and use these results, combined with experience in SVOC exposure assessment, to recommend residential exposure measurement strategies. We can predict dust concentrations reasonably well from measured air concentrations (R2 = 0.80). Partitioning models and knowledge of chemical Koa elucidate exposure pathways and suggest priorities for chemical regulation. These findings also inform study design by allowing researchers to select sampling approaches optimized for their chemicals of interest and study goals. While surface wipes are commonly used in epidemiology studies because of ease of implementation, passive air sampling may be more standardized between homes and also relatively simple to deploy. Validation of passive air sampling methods for SVOCs is a priority. PMID:25488487

  4. Is initiating tanning bed use as a minor associated with increased risky tanning behaviors and burning? An exploratory study.

    PubMed

    Seidenberg, Andrew B; Noar, Seth M; Sontag, Jennah M

    2017-12-01

    Tanning bed use is most common among youth and young adults, and is associated with an increased risk of skin cancer. Recently, numerous states have adopted restrictions on minors' access to tanning beds; however, little has been reported on how such policies may impact tanning behaviors and burning. The purpose of this study was to examine the associations between age of indoor tanning initiation and risky tanning behaviors and burning. Female students (n=567) attending a large southeastern public university completed a questionnaire (spring of 2015) assessing tanning bed use history, including age of initiation. The analytic sample was limited to participants reporting past year indoor tanning (n=134). Multivariable logistic regression was used to compare the odds of risky tanning behaviors and burning among those initiating indoor tanning before and after their 18th birthday. Participants initiating indoor tanning as a minor had significantly (ps<0.05) greater odds of using a tanning bed 10 or more times in the previous year, typically indoor tanning for ≥10min, ever indoor tanning without wearing goggles, and ever fallen asleep inside a tanning bed. Further, those that initiated as a minor had significantly greater odds of ever burning from indoor tanning (p<0.05). Indoor tanning initiation as a minor was associated with several risky tanning behaviors and burning. Youth access restrictions may help reduce the harms caused by tanning beds. Copyright © 2017. Published by Elsevier Inc.

  5. Indoor-outdoor levels of size segregated particulate matter and mono/polycyclic aromatic hydrocarbons among urban areas using solid fuels for heating

    NASA Astrophysics Data System (ADS)

    Kliucininkas, Linas; Krugly, Edvinas; Stasiulaitiene, Inga; Radziuniene, Inga; Prasauskas, Tadas; Jonusas, Arunas; Kauneliene, Violeta; Martuzevicius, Dainius

    2014-11-01

    Emissions from the fuel combustion in the energy production are causes of concern due to associated health risks, but little information is available on the impact of residential fuel burning on indoor air quality, where most of the human exposure occurs. In this complex study, concentrations of size-segregated particulate matter (PM), monocyclic and polycyclic aromatic compounds (MAHs and PAHs) at indoor and outdoor sites in six urban homes in the city of Kaunas, Lithuania, were determined over winter and summer sampling campaigns, specifically targeting the impact of the local fuel burning to the indoor air quality. PM levels observed in Kaunas during winter measurement campaign were higher compared to those in many other European settlements utilizing biomass for energy production. The particle size distribution analysis revealed that the major part of the PM mass in winter period consisted of fine particles (PM2.5). Both MAH and PAH levels were higher in winter. The indoor to outdoor ratios (I/O) of MAHs and PAHs revealed specific patterns depending on the presence of emissions sources indoors. Irrespectively of the season, I/O values were <1, suggesting that in case of the absence of an indoor pollution, the dominant source of organic compounds was from the outdoor environment. In homes with no PAH source inside, the I/O ratio equalled ranged from 0.05 to 0.36, suggesting the penetrated portion of outdoor combustion particles to the indoor air.

  6. Results from the 1987 total exposure assessment methodology (team) study in Southern California

    NASA Astrophysics Data System (ADS)

    Hartwell, T. D.; Perritt, R. L.; Pellizzari, E. D.; Michael, L. C.

    Volatile organic compound (VOC) levels in breath, personal air and fixed-site (indoor and outdoor) air were measured and compared for a sample of 50 individuals in the Los Angeles area of California. Comparisons were also made between seasons (winter and summer), between breath samples taken at three different times during the 24-h monitoring period, and between exposure levels of smokers and non-smokers. Personal air levels were higher than indoor air levels and indoor levels were much higher than outdoor levels. Air concentrations in the kitchen and living area were quite similar. Air and breath levels were higher in the winter than in the summer. Little difference was found between levels for the three breath sampling periods. Mean personal air levels of VOCs related to smoking were higher in individuals exposed to tobacco smoke vs those who were not exposed. The personal air levels of smokers and passive smokers (those non-smokers exposed to tobacco smoke) were not significantly different; while similar air levels were found in the kitchen and primary living area of homes with smokers.

  7. Health effects from indoor air pollution: case studies.

    PubMed

    White, L E; Clarkson, J R; Chang, S N

    1987-01-01

    In recent years there has been a growing awareness of the health effects associated with the presence of contaminants in indoor air. Numerous agents can accumulate in public buildings, homes and automobiles as a result of ongoing activities that normally occur in these closed spaces. Ventilation is a major factor in the control of indoor air pollutants since proper movement of air can prevent or minimize the build up of compounds in buildings. The recent emphasis on energy conservation has lead to measures which economize on energy for heating and air conditioning, but which also trap pollutants within a building. Three cases of indoor air pollution were investigated. A typical investigation of indoor air pollutant problems includes the following: interviews with building occupants; history of the building with regard to maintenance, pesticide treatment, etc.; a survey of the building and ventilation; and when warranted, sampling and analysis of air. Each case presented is unique in that atypical situations caused agents to accumulate in a building or section of a building. The indoor air problems in these cases were solved by identifying and removing the source of the offending agent and/or improving the ventilation in the building.

  8. Effects of indoor air purification by an air cleaning system (Koala technology) on semen parameters in male factor infertility: results of a pilot study.

    PubMed

    Paradisi, R; Vanella, S; Barzanti, R; Cani, C; Battaglia, C; Seracchioli, R; Venturoli, S

    2009-06-01

    A number of studies indicated a clear decline in semen quality in the past 30-50 years and there is accumulating evidence that this decline might result from exposure to high levels of air pollution. To examine the impact of environment on male reproductive ability, we undertook for the first time a pilot study on semen quality of infertile men exposed to purification of indoor air. Ten subjects with a history of unexplained male infertility and poor semen quality were exposed for at least 1 year to a cleaning indoor air system (Koala technology). The key feature of this air purifier is the unique innovative multiple filtering system. The treatment of total purification of indoor air showed neither improvements in semen parameters nor variation in reproductive hormones (P = N.S.), but induced an evident increase (P < 0.03 and more) in seminal leucocytic concentrations. Within the limits due to the small sample of subjects recruited, the sole purification of indoor air does not seem enough to improve semen quality, although the increase in leucocytic concentrations could indicate an activation of the role of immunosurveillance in a purified indoor air environment.

  9. The identification of Volatile Organic Compound's emission sources in indoor air of living spaces, offices and laboratories

    NASA Astrophysics Data System (ADS)

    Kultys, Beata

    2018-01-01

    Indoor air quality is important because people spend most of their time in closed rooms. If volatile organic compounds (VOCs) are present at elevated concentrations, they may cause a deterioration in human well-being or health. The identification of indoor emission sources is carried out by comparison indoor and outdoor air composition. The aim of the study was to determinate the concentration of VOCs in indoor air, where there was a risk of elevated levels due to the kind of work type carried out or the users complained about the symptoms of a sick building followed by an appropriate interpretation of the results to determine whether the source of the emission in the tested room occurs. The air from residential, office and laboratory was tested in this study. The identification of emission sources was based on comparison of indoor and outdoor VOCs concentration and their correlation coefficients. The concentration of VOCs in all the rooms were higher or at a similar level to that of the air sampled at the same time outside the building. Human activity, in particular repair works and experiments with organic solvents, has the greatest impact on deterioration of air quality.

  10. Reported community-level indoor residual spray coverage from two-stage cluster surveys in sub-Saharan Africa.

    PubMed

    Larsen, David A; Borrill, Lauren; Patel, Ryan; Fregosi, Lauren

    2017-06-13

    Malaria is an important cause of morbidity and mortality in malaria-endemic areas. Indoor residual spray is an effective intervention to control malaria, but high community-level coverage is needed to maximize its impact. Using thirty-four two-stage cluster surveys (e.g., demographic and health surveys) and lot quality assurance sampling, indoor residual spray was estimated at the community level (i.e. enumeration-area) across sub-Saharan Africa since 2010. For communities receiving indoor residual spray a logistic regression predicted whether community-level coverage exceeded 50% or not. Household-level coverage was equitable both in terms of wealth and urban/rural, with poorer and rural houses more likely to be sprayed than richer and urban houses. Coverage of indoor residual spray at the community level is poor across the continent, with 54% of communities receiving the intervention not reaching 50% coverage. Having >50% coverage at the community-level was not associated with increasing the number of houses sprayed in the country. Implementation and monitoring of indoor residual coverage at small geographical scales need to improve greatly to receive maximum benefit of the intervention.

  11. Psychosocial Correlates of Frequent Indoor Tanning among Adolescent Boys

    PubMed Central

    Blashill, Aaron J.

    2012-01-01

    The aim of the current study was to assess psychosocial correlates (i.e., perceived weight, weight control strategies, substance use, and victimization) of frequent indoor tanning in adolescent boys—a group at high risk for developing skin cancer. Participants (N = 7,907) were drawn from a nationally-representative sample of adolescent boys attending high school in the United States. Binary logistic regression revealed that extreme weight control strategies, particularly steroid use (odds ratio = 3.67) and compensatory vomiting (odds ratio = 2.34), along with substance use and victimization, were significantly related to frequent indoor tanning. These results highlight the role of appearance-changing, and health-risk behaviors in the context of frequent indoor tanning. Skin cancer prevention interventions may benefit from adopting approaches that integrate the treatment of body dissatisfaction and subsequent maladaptive behaviors. PMID:23276832

  12. Psychosocial correlates of frequent indoor tanning among adolescent boys.

    PubMed

    Blashill, Aaron J

    2013-03-01

    The aim of the current study was to assess psychosocial correlates (i.e., perceived weight, weight control strategies, substance use, and victimization) of frequent indoor tanning in adolescent boys-a group at high risk for developing skin cancer. Participants (N=7,907) were drawn from a nationally representative sample of adolescent boys attending high school in the United States. Binary logistic regression revealed that extreme weight control strategies, particularly steroid use (odds ratio=3.67) and compensatory vomiting (odds ratio=2.34), along with substance use and victimization, were significantly related to frequent indoor tanning. These results highlight the role of appearance-changing, and health-risk behaviors in the context of frequent indoor tanning. Skin cancer prevention interventions may benefit from adopting approaches that integrate the treatment of body dissatisfaction and subsequent maladaptive behaviors. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Measuring and modeling surface sorption dynamics of organophosphate flame retardants in chambers

    EPA Science Inventory

    Understanding the sorption mechanisms for organophosphate flame retardants (OPFRs) on impervious surfaces is important to improve our understanding of the fate and transport of OPFRs in indoor environments. Langmuir and Freundlich models are widely adopted to describe sorption be...

  14. A study of aerosol entrapment and the influence of wind speed, chamber design and foam density on polyurethane foam passive air samplers used for persistent organic pollutants.

    PubMed

    Chaemfa, Chakra; Wild, Edward; Davison, Brian; Barber, Jonathan L; Jones, Kevin C

    2009-06-01

    Polyurethane foam disks are a cheap and versatile tool for sampling persistent organic pollutants (POPs) from the air in ambient, occupational and indoor settings. This study provides important background information on the ways in which the performance of these commonly used passive air samplers may be influenced by the key environmental variables of wind speed and aerosol entrapment. Studies were performed in the field, a wind tunnel and with microscopy techniques, to investigate deployment conditions and foam density influence on gas phase sampling rates (not obtained in this study) and aerosol trapping. The study showed: wind speed inside the sampler is greater on the upper side of the sampling disk than the lower side and tethered samplers have higher wind speeds across the upper and lower surfaces of the foam disk at a wind speed > or = 4 m/s; particles are trapped on the foam surface and within the body of the foam disk; fine (<1 um) particles can form clusters of larger size inside the foam matrix. Whilst primarily designed to sample gas phase POPs, entrapment of particles ensures some 'sampling' of particle bound POPs species, such as higher molecular weight PAHs and PCDD/Fs. Further work is required to investigate how quantitative such entrapment or 'sampling' is under different ambient conditions, and with different aerosol sizes and types.

  15. Particulate Matter Mass Concentration in Residential Prefabricated Buildings Related to Temperature and Moisture

    NASA Astrophysics Data System (ADS)

    Kraus, Michal; Juhásová Šenitková, Ingrid

    2017-10-01

    Building environmental audit and the assessment of indoor air quality (IAQ) in typical residential buildings is necessary process to ensure users’ health and well-being. The paper deals with the concentrations on indoor dust particles (PM10) in the context of hygrothermal microclimate in indoor environment. The indoor temperature, relative humidity and air movement are basic significant factors determining the PM10 concentration [μg/m3]. The experimental measurements in this contribution represent the impact of indoor physical parameters on the concentration of particulate matter mass concentration. The occurrence of dust particles is typical for the almost two-thirds of interiors of the buildings. Other parameters indoor environment, such as air change rate, volume of the room, roughness and porosity of the building material surfaces, static electricity, light ions and others, were set constant and they are not taken into account in this study. The mass concentration of PM10 is measured during summer season in apartment of residential prefabricated building. The values of global temperature [°C] and relative humidity of indoor air [%] are also monitored. The quantity of particulate mass matter is determined gravimetrically by weighing according to CSN EN 12 341 (2014). The obtained results show that the temperature difference of the internal environment does not have a significant effect on the concentration PM10. Vice versa, the difference of relative humidity exhibits a difference of the concentration of dust particles. Higher levels of indoor particulates are observed for low values of relative humidity. The decreasing of relative air humidity about 10% caused 10µg/m3 of PM10 concentration increasing. The hygienic limit value of PM10 concentration is not exceeded at any point of experimental measurement.

  16. Antimüllerian hormone in relation to tobacco and marijuana use and sources of indoor heating/cooking.

    PubMed

    White, Alexandra J; Sandler, Dale P; D'Aloisio, Aimee A; Stanczyk, Frank; Whitworth, Kristina W; Baird, Donna D; Nichols, Hazel B

    2016-09-01

    To evaluate exposure to tobacco, marijuana, and indoor heating/cooking sources in relation to antimüllerian hormone (AMH) levels. Cross-sectional analysis in a sample of premenopausal women (n = 913) enrolled in the Sister Study cohort (n = 50,884). Not applicable. Women, ages 35-54 years at time of enrollment, with an archived serum sample and at least one intact ovary and classified as premenopausal. Not applicable. Serum AMH (ng/mL) levels ascertained by ultrasensitive ELISA assay. Lower AMH levels were associated with sources of indoor heating, including burning wood (-36.0%; 95% confidence interval [CI], -55.7%, -7.8%) or artificial fire logs (-45.8%; 95% CI, -67.2%, -10.4%) at least 10 times/year in a residential indoor stove/fireplace. Lower AMH levels were also observed in women who were current smokers of ≥20 cigarettes/day relative to nonsmokers (-56.2%; 95% CI, -80.3%, -2.8%) and in women with 10+ years of adult environmental tobacco smoke (ETS) exposure (-31.3%; 95% CI, -51.3%, -3.1%), but no associations were observed for marijuana use. We confirmed previously reported findings of lower AMH levels in current heavy smokers and also found associations for long-term ETS exposure and indoor burning of wood or artificial fire logs. These findings suggest that combustion by-products from common exposures can have toxic effects on the human ovary. Published by Elsevier Inc.

  17. Prediction of indoor radon/thoron concentration in a model room from exhalation rates of building materials for different ventilation rates

    NASA Astrophysics Data System (ADS)

    Kumar, Manish; Sharma, Navjeet; Sarin, Amit

    2018-05-01

    Studies have confirmed that elevated levels of radon/thoron in the human-environments can substantially increase the risk of lung cancer in general population. The building materials are the second largest contributors to indoor radon/thoron after soil and bedrock beneath dwellings. In present investigation, the exhalation rates of radon/thoron from different building materials samples have been analysed using active technique. Radon/thoron concentrations in a model room have been predicted based on the exhalation rates from walls, floor and roof. The indoor concentrations show significant variations depending upon the ventilation rate and type of building materials used.

  18. Novel method for estimation of the indoor-to-outdoor airborne radioactivity ratio following the Fukushima Daiichi Nuclear Power Plant accident.

    PubMed

    Tan, Yanliang; Ishikawa, Tetsuo; Janik, Miroslaw; Tokonami, Shinji; Hosoda, Masahiro; Sorimachi, Atsuyuki; Kearfott, Kimberlee

    2015-12-01

    The accident at the Fukushima Daiichi Nuclear Power Plant (FDNPP) in Japan resulted in significant releases of fission products. While substantial data exist concerning outdoor air radioactivity following the accident, the resulting indoor radioactivity remains pure speculation without a proper method for estimating the ratio of the indoor to outdoor airborne radioactivity, termed the airborne sheltering factor (ASF). Lacking a meaningful value of the ASF, it is difficult to assess the inhalation doses to residents and evacuees even when outdoor radionuclide concentrations are available. A simple model was developed and the key parameters needed to estimate the ASF were obtained through data fitting of selected indoor and outdoor airborne radioactivity measurement data obtained following the accident at a single location. Using the new model with values of the air exchange rate, interior air volume, and the inner surface area of the dwellings, the ASF can be estimated for a variety of dwelling types. Assessment of the inhalation dose to individuals readily follows from the value of the ASF, the person's indoor occupancy factor, and the measured outdoor radioactivity concentration. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Irritancy and Allergic Responses Induced by Exposure to the Indoor Air Chemical 4-Oxopentanal

    PubMed Central

    Anderson, Stacey E.; Franko, Jennifer; Jackson, Laurel G.; Wells, J. R.; Ham, Jason E.; Meade, B. J.

    2012-01-01

    Over the last two decades, there has been an increasing awareness regarding the potential impact of indoor air pollution on human health. People working in an indoor environment often experience symptoms such as eye, nose, and throat irritation. Investigations into these complaints have ascribed the effects, in part, to compounds emitted from building materials, cleaning/consumer products, and indoor chemistry. One suspect indoor air contaminant that has been identified is the dicarbonyl 4-oxopentanal (4-OPA). 4-OPA is generated through the ozonolysis of squalene and several high-volume production compounds that are commonly found indoors. Following preliminary workplace sampling that identified the presence of 4-OPA, these studies examined the inflammatory and allergic responses to 4-OPA following both dermal and pulmonary exposure using a murine model. 4-OPA was tested in a combined local lymph node assay and identified to be an irritant and sensitizer. A Th1-mediated hypersensitivity response was supported by a positive response in the mouse ear swelling test. Pulmonary exposure to 4-OPA caused a significant elevation in nonspecific airway hyperreactivity, increased numbers of lung-associated lymphocytes and neutrophils, and increased interferon-γ production by lung-associated lymph nodes. These results suggest that both dermal and pulmonary exposure to 4-OPA may elicit irritant and allergic responses and may help to explain some of the adverse health effects associated with poor indoor air quality. PMID:22403157

  20. Fast fingerprint database maintenance for indoor positioning based on UGV SLAM.

    PubMed

    Tang, Jian; Chen, Yuwei; Chen, Liang; Liu, Jingbin; Hyyppä, Juha; Kukko, Antero; Kaartinen, Harri; Hyyppä, Hannu; Chen, Ruizhi

    2015-03-04

    Indoor positioning technology has become more and more important in the last two decades. Utilizing Received Signal Strength Indicator (RSSI) fingerprints of Signals of OPportunity (SOP) is a promising alternative navigation solution. However, as the RSSIs vary during operation due to their physical nature and are easily affected by the environmental change, one challenge of the indoor fingerprinting method is maintaining the RSSI fingerprint database in a timely and effective manner. In this paper, a solution for rapidly updating the fingerprint database is presented, based on a self-developed Unmanned Ground Vehicles (UGV) platform NAVIS. Several SOP sensors were installed on NAVIS for collecting indoor fingerprint information, including a digital compass collecting magnetic field intensity, a light sensor collecting light intensity, and a smartphone which collects the access point number and RSSIs of the pre-installed WiFi network. The NAVIS platform generates a map of the indoor environment and collects the SOPs during processing of the mapping, and then the SOP fingerprint database is interpolated and updated in real time. Field tests were carried out to evaluate the effectiveness and efficiency of the proposed method. The results showed that the fingerprint databases can be quickly created and updated with a higher sampling frequency (5Hz) and denser reference points compared with traditional methods, and the indoor map can be generated without prior information. Moreover, environmental changes could also be detected quickly for fingerprint indoor positioning.

  1. Outdoor and indoor particle characterization from a large and uncontrolled combustion of a tire landfill.

    PubMed

    Artíñano, B; Gómez-Moreno, F J; Díaz, E; Amato, F; Pandolfi, M; Alonso-Blanco, E; Coz, E; García-Alonso, S; Becerril-Valle, M; Querol, X; Alastuey, A; van Drooge, B L

    2017-09-01

    A large and uncontrolled fire of a tire landfill started in Seseña (Toledo, Spain) on May 13, 2016. An experimental deployment was immediately launched in the area for measuring regulated and non-standard air quality parameters to assess the potential impact of the plume at local and regional levels. Outdoor and indoor measurements of different parameters were carried out at a near school, approximately 700m downwind the burning tires. Real time measurements of ambient black carbon (BC) and total number particle concentrations were identified as good tracers of the smoke plume. Simultaneous peaks allowed us to characterize situations of the plume impact on the site. Outdoor total particle number concentrations reached in these occasions 3.8×10 5 particlescm -3 (on a 10min resolution) whereas the indoor concentration was one order of magnitude lower. BC mass concentrations in ambient air were in the range of 2 to 7μgm -3 , whereas concentrations<2μgm -3 were measured indoor. Indoor and outdoor deposited inhalable dust was sampled and chemically characterized. Both indoor and outdoor dust was enriched in tire components (Zn, sulfate) and PAHs associated to the tire combustion process. Infiltration processes have been documented for BC and particle number concentrations causing increases in indoor concentrations. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. The associations of indoor environment and psychosocial factors on the subjective evaluation of Indoor Air Quality among lower secondary school students: a multilevel analysis.

    PubMed

    Finell, E; Haverinen-Shaughnessy, U; Tolvanen, A; Laaksonen, S; Karvonen, S; Sund, R; Saaristo, V; Luopa, P; Ståhl, T; Putus, T; Pekkanen, J

    2017-03-01

    Subjective evaluation of Indoor Air Quality (subjective IAQ) reflects both building-related and psychosocial factors, but their associations have rarely been studied other than on the individual level in occupational settings and their interactions have not been assessed. Therefore, we studied whether schools' observed indoor air problems and psychosocial factors are associated with subjective IAQ and their potential interactions. The analysis was performed with a nationwide sample (N = 195 schools/26946 students) using multilevel modeling. Two datasets were merged: (i) survey data from students, including information on schools' psychosocial environment and subjective IAQ, and (ii) data from school principals, including information on observed indoor air problems. On the student level, school-related stress, poor teacher-student relationship, and whether the student did not easily receive help from school personnel, were significantly associated with poor subjective IAQ. On the school level, observed indoor air problem (standardized β = -0.43) and poor teacher-student relationship (standardized β = -0.22) were significant predictors of poor subjective IAQ. In addition, school-related stress was associated with poor subjective IAQ, but only in schools without observed indoor air problem (standardized β = -0.44). © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Indoor environmental quality in French dwellings and building characteristics

    NASA Astrophysics Data System (ADS)

    Langer, Sarka; Ramalho, Olivier; Derbez, Mickaël; Ribéron, Jacques; Kirchner, Severine; Mandin, Corinne

    2016-03-01

    A national survey on indoor environmental quality covering 567 residences in mainland France was performed during 2003-2005. The measured parameters were temperature, relative humidity, CO2, and the indoor air pollutants: fourteen individual volatile organic compounds (VOC), four aldehydes and particulate matter PM10 and PM2.5. The measured indoor concentrations were analyzed for correlations with the building characteristics: type of dwelling, period of construction, dwelling location, type of ventilation system, building material, attached garage and retrofitting. The median night time air exchange rate (AER) for all dwellings was 0.44 h-1. The night time AER was higher in apartments (median = 0.49 h-1) than in single-family houses (median = 0.41 h-1). Concentration of formaldehyde was approximately 30% higher in dwellings built after 1990 compared with older ones; it was higher in dwellings with mechanical ventilation and in concrete buildings. The VOC concentrations depended on the building characteristics to various extents. The sampling season influenced the majority of the indoor climate parameters and the concentrations of the air pollutants to a higher degree than the building characteristics. Multivariate linear regression models revealed that the indoor-outdoor difference in specific humidity, a proxy for number of occupants and their indoor activities, remained a significant predictor for most gaseous and particulate air pollutants. The other strong predictors were outdoor concentration, smoking, attached garage and AER (in descending order).

  4. Plant leaves as indoor air passive samplers for volatile organic compounds (VOCs).

    PubMed

    Wetzel, Todd A; Doucette, William J

    2015-03-01

    Volatile organic compounds (VOCs) enter indoor environments through internal and external sources. Indoor air concentrations of VOCs vary greatly but are generally higher than outdoors. Plants have been promoted as indoor air purifiers for decades, but reports of their effectiveness differ. However, while air-purifying applications may be questionable, the waxy cuticle coating on leaves may provide a simple, cost-effective approach to sampling indoor air for VOCs. To investigate the potential use of plants as indoor air VOC samplers, a static headspace approach was used to examine the relationship between leaf and air concentrations, leaf lipid contents and octanol-air partition coefficients (Koa) for six VOCs and four plant species. The relationship between leaf and air concentrations was further examined in an actual residence after the introduction of several chlorinated VOC emission sources. Leaf-air concentration factors (LACFs), calculated from linear regressions of the laboratory headspace data, were found to increase as the solvent extractable leaf lipid content and Koa value of the VOC increased. In the studies conducted in the residence, leaf concentrations paralleled the changing air concentrations, indicating a relatively rapid air to leaf VOC exchange. Overall, the data from the laboratory and residential studies illustrate the potential for plant leaves to be used as cost effective, real-time indoor air VOC samplers. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Environmental site assessments and audits: Building inspection requirements

    NASA Astrophysics Data System (ADS)

    Lange, John H.; Kaiser, Genevieve; Thomulka, Kenneth W.

    1994-01-01

    Environmental site assessment criteria were originally developed by organizations that focused, almost exclusively, on surface, subsurface, and pollution source contamination. Many of the hazards associated with indoor environments and building structures were traditionally not considered when evaluating sources and entities of environmental pollution. Since a large number of building materials are potentially hazardous, careful evaluation is necessary. Until recently, little information on building inspection requirements of environmental problems has been published. Traditionally, asbestos has been the main component of concern. The ever-changing environmental standards have dramatically expanded the scope of building surveys. Indoor environmental concerns, for example, currently include formaldehyde, lead-based paint, polychlorinated biphenyls, radon, and indoor air pollution. Environmental regulations are being expanded and developed that specifically include building structures. These regulatory standards are being triggered by an increased awareness of health effects from indoor exposure, fires, spills, and other accidents that have resulted in injury, death, and financial loss. This article discusses various aspects of assessments for building structures.

  6. Integration of a photocatalytic multi-tube reactor for indoor air purification in HVAC systems: a feasibility study.

    PubMed

    van Walsem, Jeroen; Roegiers, Jelle; Modde, Bart; Lenaerts, Silvia; Denys, Siegfried

    2018-04-24

    This work is focused on an in-depth experimental characterization of multi-tube reactors for indoor air purification integrated in ventilation systems. Glass tubes were selected as an excellent photocatalyst substrate to meet the challenging requirements of the operating conditions in a ventilation system in which high flow rates are typical. Glass tubes show a low-pressure drop which reduces the energy demand of the ventilator, and additionally, they provide a large exposed surface area to allow interaction between indoor air contaminants and the photocatalyst. Furthermore, the performance of a range of P25-loaded sol-gel coatings was investigated, based on their adhesion properties and photocatalytic activities. Moreover, the UV light transmission and photocatalytic reactor performance under various operating conditions were studied. These results provide vital insights for the further development and scaling up of multi-tube reactors in ventilation systems which can provide a better comfort, improved air quality in indoor environments, and reduced human exposure to harmful pollutants.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    LaFreniere, L. M.

    Carbon tetrachloride contamination in groundwater at Morrill, Kansas, was initially identified in 1985 during statewide testing of public water supply wells for volatile organic compounds (VOCs). High levels of nitrate were also present in the wells. The city of Morrill is located in Brown County in the northeastern corner of the state, about 7 mi east of Sabetha (Figure 1.1). The population of Morrill as of the 2010 Census was approximately 230 (down from 277 in 2000). All residents of Morrill now obtain their drinking water from the Sabetha municipal water system via a pipeline constructed in 1991. The findingsmore » of the April 2011 and October 2011 monitoring events at Morrill support the following conclusions: (1) Groundwater flow during the 2011 review period (as in prior years) was predominantly to the south, from the vicinity of the former CCC/USDA facility toward Terrapin Creek. Automatic water level monitoring data suggest that spring precipitation and recharge represent the predominant factors affecting the local groundwater level patterns. (2) No significant changes were observed in the concentration or distribution of carbon tetrachloride in groundwater during the spring and fall 2011 monitoring events versus the spring and fall 2010 monitoring events. In October 2011, a maximum carbon tetrachloride concentration of 49 {micro}g/L was identified in groundwater at well MW3S on the former CCC/USDA facility, with concentrations decreasing downgradient toward Terrapin Creek. (3) Since 2004, the accumulated results of 15 sampling events have demonstrated a significant decline in the maximum detected concentration of carbon tetrachloride in groundwater. In 1995, the contaminant was detected at the former CCC/USDA facility at 390 {micro}g/L, while the current maximum levels are < 50 {micro}g/L. The residual contaminant plume extending from the former CCC/USDA facility southward toward Terrapin Creek is well-defined and slowly declining in concentration naturally. (4) No carbon tetrachloride contamination was detected in 2011 in surface waters or shallow streambed sediments sampled at five locations along Terrapin Creek, downgradient from the former CCC/USDA facility. These results indicate that Terrapin Creek remains unaffected by the carbon tetrachloride plume. (5) Since 2007, the accumulated results of 10 monitoring events for surface water and sediment in Terrapin Creek have demonstrated no impact to the sediment and surface waters of the creek by carbon tetrachloride and no imminent risk for further degradation of the creek. (6) Terrapin Creek (tributary segment 308 to Walnut Creek) receives discharge from the Morrill wastewater treatment plant and several confined animal feeding operations regulated by the KDHE. The Walnut Creek watershed is designated by the KDHE as impaired by fecal coliform bacteria. Terrapin Creek is classified by the KDHE as not open to or accessible by the public for contact recreation and does not support the food procurement designated use (KDHE 2010b). (7) In July 2011, trace concentrations of carbon tetrachloride were detected in vegetation samples collected from trees at 2 of the 42 sampled locations south (downgradient) of the former CCC/USDA facility. (8) Sampling of indoor air in August 2010 to evaluate the potential for vapor intrusion into homes overlying and within 100 ft laterally of the identified carbon tetrachloride plume resulted in no detections of carbon tetrachloride. Low concentrations of chloroform, indicative of indoor air sources, were detected. Low radon levels were also detected. The results indicate no evidence of upward migration of vapors from the low-level carbon tetrachloride contamination in groundwater to indoor air.« less

  8. [Concentration of biocides in indoor rooms using pyrethroids as an example].

    PubMed

    Walker, G; Keller, R; Beckert, J; Butte, W

    1994-06-01

    Pyrethroids are an analogous substance group to one of the oldest known, naturally occurring insecticides pyrethrum and have replaced a number of pesticides such as Lindane, DDT and PCP on the market. Biocides are more persistent indoors than in nature, which could lead to permanent health hazards for the people concerned. Within a few days after application pyrethroids are rarely detected in room air but can be traced for a long time on textiles, furniture and in dust particles (3, 8). The investigation results of approx. 100 analyses from dust and carpet samples show that approx. 1/3 of these samples are positive for at least one pyrethroid and contain a concentration of > 2 mg substance per kg sample. The evaluation of 35 air samples taken from rooms where substances containing pyrethroids had been used at least a month prior to the investigation (the samples were sampled on active charcoal or Chromosorb) showed that pyrethroids could no longer be traced above the detection limit of 0.05-0.1 micrograms/m3. We therefore think that when investigating a contamination of rooms by biocides it is more advisable to determine pyrethroid and its synergists in the suspended dust portion and corresponding dust sample rather than analysing air by adsorption to active charcoal, Chromosorb or other carrier materials. From the observed concentrations of biocides one could conclude that in an indoor setting secondary contamination by biocides plays a more significant role in the total-body-load than that of air contamination.

  9. Surface-deposition and Distribution of the Radon (222Rn and 220Rn) Decay Products Indoors

    NASA Astrophysics Data System (ADS)

    Espinosa, G.; Tommasino, Luigi

    The exposure to radon (222Rn and 220Rn) decay products is of great concern both in dwellings and workplaces. The model to estimate the lung dose refers to the deposition mechanisms and particle sizes. Unfortunately, most of the dose data available are based on the measurement of radon concentration and the concentration of radon decay products. These combined measurements are widely used in spite of the fact that accurate dose assessments require information on the particle deposition mechanisms and the spatial distribution of radon decay products indoors. Most of the airborne particles and/or radon decay products are deposited onto indoor surfaces, which deposition makes the radon decay products unavailable for inhalation. These deposition processes, if properly known, could be successfully exploited to reduce the exposure to radon decay products. In spite of the importance of the surface deposition of the radon decay products, both for the correct evaluation of the dose and for reducing the exposure, little or no efforts have been made to investigate these deposition processes. Recently, two parallel investigations have been carried out in Rome and at Universidad Nacional Autónoma de México (UNAM) in Mexico City respectively, which address the issue of the surface-deposited radon decay products. Even though these investigations have been carried independently, they complement one another. It is with these considerations in mind that it was decided to report both investigations in the same paper.

  10. Evidence for Interactions between Surface Water and Periphyton Biofilms in Artificial Streams

    EPA Science Inventory

    Studies suggest that periphyton in streambeds can harbor fecal indicator bacteria (FIB) and, under certain circumstances, can be transferred from the periphyton biofilm into the surface water. An indoor mesocosm study was conducted at the U.S. Environmental Protection Agency Expe...

  11. Measuring and Modeling Surface Sorption Dynamics of Organophosphate Flame Retardants in Chambers

    EPA Science Inventory

    Understanding the sorption mechanisms for organophosphate flame retardants (OPFRs) on impervious surfaces is important if we are to improve our understanding of the fate and transport of OPFRs in indoor environments. Traditional Langmuir and Freundlich models are widely adopted t...

  12. Employing ASHRAE Standard 62-1989 in urban building environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meckler, M.

    1991-01-01

    Indoor air quality (IAQ) is a result of a complex relationship between the contamination sources in a building, the ventilation rate, and the dilution of the indoor air contaminant concentrations with outdoor air. This complex relationship is further complicated by outdoor sources used for dilution air and pollution sinks in a building which may modify or remove contaminants. This paper reports that the factors influencing IAQ in a building are: emissions from indoor contamination sources, dilution rate of outdoor ventilation air, quality of the outdoor dilution air, and systems and materials in a building that change the concentrations of contaminants.more » Emissions from contaminant sources in a building are the primary determinant of IAQ. They include building materials, consumer products, cleaners, furnishings, combustion appliances and processes, biological growth from standing water and damp surfaces and building occupants. These factors combined with the emissions from indoor air contamination sources such as synthetic building materials, modern office equipment, and cleaning and biological agents are believed to increase the levels of indoor air contamination. The physiological reactions to these contaminants, coupled with the psychosocial stresses of the modern office environment, and the wide range of human susceptibility to indoor air contaminants led to the classification of acute building sicknesses: sick building syndrome (SBS), building-related illness (BRI), and multiple chemical sensitivity (MCS).« less

  13. Scene analysis for a breadboard Mars robot functioning in an indoor environment

    NASA Technical Reports Server (NTRS)

    Levine, M. D.

    1973-01-01

    The problem is delt with of computer perception in an indoor laboratory environment containing rocks of various sizes. The sensory data processing is required for the NASA/JPL breadboard mobile robot that is a test system for an adaptive variably-autonomous vehicle that will conduct scientific explorations on the surface of Mars. Scene analysis is discussed in terms of object segmentation followed by feature extraction, which results in a representation of the scene in the robot's world model.

  14. Assessment of the impact of oxidation processes on indoor air pollution using the new time-resolved INCA-Indoor model

    NASA Astrophysics Data System (ADS)

    Mendez, Maxence; Blond, Nadège; Blondeau, Patrice; Schoemaecker, Coralie; Hauglustaine, Didier A.

    2015-12-01

    INCA-Indoor, a new indoor air quality (IAQ) model, has been developed to simulate the concentrations of volatile organic compounds (VOC) and oxidants considering indoor air specific processes such as: emission, ventilation, surface interactions (sorption, deposition, uptake). Based on the detailed version of SAPRC-07 chemical mechanism, INCA-Indoor is able to analyze the contribution of the production and loss pathways of key chemical species (VOCs, oxidants, radical species). The potential of this model has been tested through three complementary analyses: a comparison with the most detailed IAQ model found in the literature, focusing on oxidant species; realistic scenarios covering a large range of conditions, involving variable OH sources like HONO; and the investigation of alkenes ozonolysis under a large range of indoor conditions that can increase OH and HO2 concentrations. Simulations have been run changing nitrous acid (HONO) concentrations, NOx levels, photolysis rates and ventilation rates, showing that HONO can be the main source of indoor OH. Cleaning events using products containing D-limonene have been simulated at different periods of the day. These scenarios show that HOX concentrations can significantly increase in specific conditions. An assessment of the impact of indoor chemistry on the potential formation of secondary species such as formaldehyde (HCHO) and acetaldehyde (CH3CHO) has been carried out under various room configuration scenarios and a study of the HOx budget for different realistic scenarios has been performed. It has been shown that, under the simulation conditions, formaldehyde can be affected by oxidant concentrations via chemical production which can account for more than 10% of the total production, representing 6.5 ppb/h. On the other hand, acetaldehyde production is affected more by oxidation processes. When the photolysis rates are high, chemical processes are responsible for about 50% of the total production of acetaldehyde (9 ppb/h).

  15. Outdoor and indoor UFP in primary schools across Barcelona.

    PubMed

    Reche, C; Viana, M; Rivas, I; Bouso, L; Àlvarez-Pedrerol, M; Alastuey, A; Sunyer, J; Querol, X

    2014-09-15

    Indoor and outdoor measurements of real-time ultrafine particles (UFP; N10-700 in this study) number concentration and average diameter were collected twice at 39 primary schools located in Barcelona (Spain), with classrooms naturally ventilated under warm weather conditions. Simultaneous outdoor N concentration measurements at schools under different traffic exposures showed the important role of this source, with higher levels by 40% on average at schools near heavy traffic, highlighting thus the increased exposure of children due to urban planning decisions. A well-defined spatial pattern of outdoor UFP levels was observed. Midday increases in outdoor N levels mainly attributed to nucleation processes have been recorded both at high and low temperatures in several of the outdoor school sites (increasing levels by 15%-70%). The variation of these increases also followed a characteristic spatial pattern, pointing at schools' location as a key variable in terms of UFP load owing to the important contribution of traffic emissions. Indoor N concentrations were to some extent explained by outdoor N concentrations during school hours, together with average temperatures, related with natural ventilation. Outdoor midday increases were generally mimicked by indoor N concentrations, especially under warm temperatures. At specific cases, indoor concentrations during midday were 30%-40% higher than outdoor. The time scale of these observations evidenced the possible role of: a) secondary particle formation enhanced by indoor precursors or conditions, maybe related with surface chemistry reactions mediated by O3, and/or b) UFP from cooking activities. Significant indoor N increases were detected after school hours, probably associated with cleaning activities, resulting in indoor N concentrations up to 3 times higher than those in outdoor. A wide variability of indoor/outdoor ratios of N concentrations and mean UFP sizes was detected among schools and measurement periods, which seems to be partly associated with climatic conditions and O3 levels, although further research is required. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. SAMPLING ARTIFACTS IN MEASUREMENT OF ELEMENTAL AND ORGANIC CARBON: LOW VOLUME SAMPLING IN INDOOR AND OUTDOOR ENVIRONMENTS

    EPA Science Inventory

    Experiments were completed to determine the extent of artifacts from sampling elemental carbon (EC) and organic carbon (OC) under sample conditions consistent with personal sampling. Two different types of experiments were completed; the first examined possible artifacts from oil...

  17. From air to clothing: characterizing the accumulation of semi-volatile organic compounds to fabrics in indoor environments.

    PubMed

    Saini, A; Okeme, J O; Mark Parnis, J; McQueen, R H; Diamond, M L

    2017-05-01

    Uptake kinetics of semi-volatile organic compounds (SVOCs) present indoors, namely phthalates and halogenated flame retardants (HFRs), were characterized for cellulose-based cotton and rayon fabrics. Cotton and rayon showed similar accumulation of gas- and particle-phase SVOCs, when normalized to planar surface area. Accumulation was 3-10 times greater by rayon than cotton, when normalized to Brunauer-Emmett-Teller (BET) specific surface area which suggests that cotton could have a longer linear uptake phase than rayon. Linear uptake rates of eight consistently detected HFRs over 56 days of 0.35-0.92 m 3 /day.dm 2 planar surface area and mass transfer coefficients of 1.5-3.8 m/h were statistically similar for cotton and rayon and similar to those for uptake to passive air sampling media. These results suggest air-side controlled uptake and that, on average, 2 m 2 of clothing typically worn by a person would sequester the equivalent of the chemical content in 100 m 3 of air per day. Distribution coefficients between fabric and air (K') ranged from 6.5 to 7.7 (log K') and were within the range of partition coefficients measured for selected phthalates as reported in the literature. The distribution coefficients were similar for low molecular weight HFRs, and up to two orders of magnitude lower than the equilibrium partition coefficients estimated using the COSMO-RS model. Based on the COSMO-RS model, time to reach 95% of equilibrium for PBDEs between fabric and gas-phase compounds ranged from 0.1 to >10 years for low to high molecular weight HFRs. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Occurrence of polybrominated diphenyl ethers in floor and elevated surface house dust from Shanghai, China.

    PubMed

    Niu, Dong; Qiu, Yanling; Li, Li; Zhou, Yihui; Du, Xinyu; Zhu, Zhiliang; Chen, Ling; Lin, Zhifen

    2018-04-24

    House dust is the main source of human exposure to flame retardants by ingestion. This study investigated the occurrence of polybrominated diphenyl ethers (PBDEs) in indoor dust from 22 houses in Shanghai, China. House dust was separately collected from the floor and elevated furnishings surface (mostly between 0.5 and 2 m height) for comparison. The concentrations of ∑ 22 PBDEs ranged from 19.4 to 3280 ng/g (with a geometric mean of 203 ng/g) and from 55.1 to 792 ng/g (with a geometric mean of 166 ng/g) in floor dust (FD) and elevated surface dust (ESD), respectively. BDE-209 was the predominant congener, accounting for about 73.1% of total PBDE burdens. In terms of congener profiles, the comparison of FD and ESD revealed no significant differences except for the ratio of BDE-47/BDE-99. ESD samples displayed a ratio of BDE-47/BDE-99 very similar to commercial penta-BDE products DE-71 while the ratio in FD was exceptionally higher. Significant correlation was found between concentrations of commercial penta-BDE compositions in FD and ESD (p < 0.05). Except for some occasional values, PBDE levels in house dust exhibited temporal stability. Human exposure to PBDEs via dust ingestion was estimated. The highest daily intake of PBDEs was for toddlers by using 95th percentile concentrations of PBDEs via high dust ingestion in FD (23.07 ng/kg bw/day). About 20-fold difference in exposure estimates between toddlers and adults supports that toddlers are facing greater risk from indoor floor dust. Expectedly, this study highlighted the point that residents in Shanghai were exposed to low doses of PBDEs in house dust.

  19. Hyperspectral Analysis for Standoff Detection of Dimethyl ...

    EPA Pesticide Factsheets

    Journal Article Detecting organophosphates in indoor settings requires more efficient and faster methods of surveying large surface areas than conventional approaches, which sample small surface areas followed by extraction and analysis. This study examined a standoff detection technique utilizing hyperspectral imaging for analysis of building materials in near-real time. In this proof-of-concept study, dimethyl methylphosphonate (DMMP) was applied to stainless steel and laminate coupons and spectra were collected during active illumination. Absorbance bands at approximately 1275 cm-1 and 1050 cm-1 were associated with phosphorus-oxygen double bond (P=O) and phosphorus-oxygen-carbon (P-O-C) bond stretches of DMMP, respectively. The magnitude of these bands increased linearly (r2 = 0.93) with DMMP across the full absorbance spectrum, between ν1 = 877 cm-1 to ν2 = 1262 cm-1. Comparisons between bare and contaminated surfaces on stainless steel using the spectral contrast angle technique indicated that the bare samples showed no sign of contamination, with large uniformly distributed contrast angles of 45˚-55˚, while the contaminated samples had smaller spectral contact angles of 40° in the uncontaminated region. The laminate contaminated region exhibited contact angles of < 25°. To the best of our knowledge, this is the first report to demonstrate that hyperspectral imaging can be used to detect DMMP on building materials, with detection levels similar to c

  20. Undisturbed dust as a metric of long-term indoor insecticide exposure: Residential DDT contamination from indoor residual spraying and its association with serum levels in the VHEMBE cohort.

    PubMed

    Gaspar, Fraser W; Chevrier, Jonathan; Bornman, Riana; Crause, Madelein; Obida, Muvhulawa; Barr, Dana Boyd; Bradman, Asa; Bouwman, Henk; Eskenazi, Brenda

    2015-12-01

    Although approximately 123 million people may be exposed to high levels of insecticides through the use of indoor residual spraying (IRS) for malaria control, few studies exist on indoor insecticide contamination due to IRS and its relationship with human exposure. In the present study, we developed a sampling method to collect undisturbed dust from 50 homes in Limpopo, South Africa, a region where dichlorodiphenyltrichloroethane (DDT) has been used in IRS programs to prevent malaria for ~70years. We quantified DDT and its degradation products, dichlorodiphenyldichloroethylene (DDE), and dichlorodiphenyldichloroethane (DDD) in dust samples to determine dust loading levels and compared these levels to paired serum concentrations of p,p'-DDT and p,p'-DDE in women residents. p,p'-DDT and p,p'-DDE had the highest detection frequencies in both dust (58% and 34% detection, respectively) and serum samples (98% and 100% detection, respectively). Significantly higher detection frequencies for o,p'-DDT, p,p'-DDE, and p,p'-DDD were observed in dust samples collected in buildings that had been previously sprayed for malaria control. We also observed a significant, positive association between dust loading and serum concentrations of p,p'-DDT and p,p'-DDE (Spearman's rho=0.68 and 0.54, respectively). Despite the low detection frequency in dust, our results indicate that undisturbed dust may be a good metric to quantify long-term home exposure to DDT-related compounds and that contamination of the home environment may be an important determinant/source of DDT and DDE exposure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. A first generation dynamic ingress, redistribution and transport model of soil track-in: DIRT.

    PubMed

    Johnson, D L

    2008-12-01

    This work introduces a spatially resolved quantitative model, based on conservation of mass and first order transfer kinetics, for following the transport and redistribution of outdoor soil to, and within, the indoor environment by track-in on footwear. Implementations of the DIRT model examined the influence of room size, rug area and location, shoe size, and mass transfer coefficients for smooth and carpeted floor surfaces using the ratio of mass loading on carpeted to smooth floor surfaces as a performance metric. Results showed that in the limit for large numbers of random steps the dual aspects of deposition to and track-off from the carpets govern this ratio. Using recently obtained experimental measurements, historic transport and distribution parameters, cleaning efficiencies for the different floor surfaces, and indoor dust deposition rates to provide model boundary conditions, DIRT predicts realistic floor surface loadings. The spatio-temporal variability in model predictions agrees with field observations and suggests that floor surface dust loadings are constantly in flux; steady state distributions are hardly, if ever, achieved.

  2. Indoor and Outdoor Levels and Sources of Submicron Particles (PM1) at Homes in Edmonton, Canada.

    PubMed

    Bari, Md Aynul; Kindzierski, Warren B; Wallace, Lance A; Wheeler, Amanda J; MacNeill, Morgan; Héroux, Marie-Ève

    2015-06-02

    Exposure to submicron particles (PM1) is of interest due to their possible chronic and acute health effects. Seven consecutive 24-h PM1 samples were collected during winter and summer 2010 in a total of 74 nonsmoking homes in Edmonton, Canada. Median winter concentrations of PM1 were 2.2 μg/m(3) (interquartile range, IQR = 0.8-6.1 μg/m(3)) and 3.3 μg/m(3) (IQR = 1.5-6.9 μg/m(3)) for indoors and outdoors, respectively. In the summer, indoor (median 4.4 μg/m(3), IQR = 2.4-8.6 μg/m(3)) and outdoor (median 4.3 μg/m(3), IQR = 2.6-7.4 μg/m(3)) levels were similar. Positive matrix factorization (PMF) was applied to identify and apportion indoor and outdoor sources of elements in PM1 mass. Nine sources contributing to both indoor and outdoor PM1 concentrations were identified including secondary sulfate, soil, biomass smoke and environmental tobacco smoke (ETS), traffic, settled and mixed dust, coal combustion, road salt/road dust, and urban mixture. Three additional indoor sources were identified i.e., carpet dust, copper-rich, and silver-rich. Secondary sulfate, soil, biomass smoke and ETS contributed more than 70% (indoors: 0.29 μg/m(3), outdoors: 0.39 μg/m(3)) of measured elemental mass in PM1. These findings can aid understanding of relationships between submicron particles and health outcomes for indoor/outdoor sources.

  3. Characterization of fine particulate matter in Ohio: Indoor, outdoor, and personal exposures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crist, Kevin C.; Liu, Bian; Kim, Myoungwoo

    2008-01-15

    Ambient, indoor, and personal PM{sub 2.5} concentrations were assessed based on an exhaustive study of PM{sub 2.5} performed in Ohio from 1999 to 2000. Locations in Columbus, one in an urban corridor and the other in a suburban area were involved. A third rural location in Athens, Ohio, was also established. At all three locations, elementary schools were utilized to determine outdoor, indoor, and personal PM{sub 2.5} concentrations for fourth and fifth grade students using filter-based measurements. Three groups of 30 students each were used for personal sampling at each school. Continuous ambient PM{sub 2.5} mass concentrations were also measuredmore » with tapered element oscillating microbalances (TEOMs). At all three sites, personal and indoor PM{sub 2.5} concentrations exceeded outdoor levels. This trend is consistent on all week days and most evident in the spring as compared to fall and winter. The ambient PM{sub 2.5} concentrations were similar among the three sites, suggesting the existence of a common regional source influence. At all the three sites, larger variations were found in personal and indoor PM{sub 2.5} than ambient levels. The strongest correlations were found between indoor and personal concentrations, indicating that personal PM{sub 2.5} exposures were significantly affected by indoor PM{sub 2.5} than by ambient PM{sub 2.5}. This was further confirmed by the indoor to outdoor (I/O) ratios of PM{sub 2.5} concentrations, which were greater when school was in session than non-school days when the students were absent.« less

  4. First evaluation of the Behavioral Addiction Indoor Tanning Screener (BAITS) in a nationwide representative sample.

    PubMed

    Diehl, K; Görig, T; Breitbart, E W; Greinert, R; Hillhouse, J J; Stapleton, J L; Schneider, S

    2018-01-01

    Evidence suggests that indoor tanning may have addictive properties. However, many instruments for measuring indoor tanning addiction show poor validity and reliability. Recently, a new instrument, the Behavioral Addiction Indoor Tanning Screener (BAITS), has been developed. To test the validity and reliability of the BAITS by using a multimethod approach. We used data from the first wave of the National Cancer Aid Monitoring on Sunbed Use, which included a cognitive pretest (August 2015) and a Germany-wide representative survey (October to December 2015). In the cognitive pretest 10 users of tanning beds were interviewed and 3000 individuals aged 14-45 years were included in the representative survey. Potential symptoms of indoor tanning addiction were measured using the BAITS, a brief screening survey with seven items (answer categories: yes vs. no). Criterion validity was assessed by comparing the results of BAITS with usage parameters. Additionally, we tested internal consistency and construct validity. A total of 19·7% of current and 1·8% of former indoor tanning users were screened positive for symptoms of a potential indoor tanning addiction. We found significant associations between usage parameters and the BAITS (criterion validity). Internal consistency (reliability) was good (Kuder-Richardson-20, 0·854). The BAITS was shown to be a homogeneous construct (construct validity). Compared with other short instruments measuring symptoms of a potential indoor tanning addiction, the BAITS seems to be a valid and reliable tool. With its short length and the binary items the BAITS is easy to use in large surveys. © 2017 British Association of Dermatologists.

  5. Rush-hour aromatic and chlorinated hydrocarbons in selected subway stations of Shanghai, China.

    PubMed

    Zhang, Yanli; Li, Chunlei; Wang, Xinming; Guo, Hai; Feng, Yanli; Chen, Jianmin

    2012-01-01

    Air samples were collected simultaneously at platform, mezzanine and outdoor in five typical stations of subway system in Shanghai, China using stainless steel canisters and analyzed by gas chromatography-mass selective detector (GC-MSD) after cryogenic preconcentration. Benzene, toluene, ethylbenzene and xylenes (BTEX) at the platforms and mezzanines inside the stations averaged (10.3 +/- 2.1), (38.7 +/- 9.0), (19.4 +/- 10.1) and (30.0 +/- 11.1) microg/m3, respectively; while trichloroethylene (TrCE), tetrachloroethylene (TeCE) and para-dichlorobenzene (pDCB), vinyl chloride and carbon tetrachloride were the most abundant chlorinated hydrocarbons inside the stations with average levels of (3.6 +/- 1.3), (1.3 +/- 0.5), (4.1 +/- 1.1), (2.2 +/- 1.1) and (1.2 +/- 0.3) microg/m3, respectively. Mean levels of major aromatic and chlorinated hydrocarbons were higher indoor (platforms and mezzanines) than outdoor with average indoor/outdoor (I/O) ratios of 1.1-9.5, whereas no significant indoor/outdoor differences were found except for benzene and TrCE. The highly significant mutual correlations (p < 0.01) for BTEX between indoor and outdoor and their significant correlation (p < 0.05) with methyl tert-butyl ether (MTBE), a marker of traffic-related emission without other indoor and outdoor sources, indicated that BTEX were introduced into the subway stations from indoor/outdoor air exchange and traffic emission should be their dominant source. TrCE and pDCB were mainly from indoor emission and TeCE might have both indoor emission sources and contribution from outdoor air, especially in the mezzanines.

  6. Predictors of Indoor Air Concentrations in Smoking and Non-Smoking Residences

    PubMed Central

    Héroux, Marie-Eve; Clark, Nina; Van Ryswyk, Keith; Mallick, Ranjeeta; Gilbert, Nicolas L.; Harrison, Ian; Rispler, Kathleen; Wang, Daniel; Anastassopoulos, Angelos; Guay, Mireille; MacNeill, Morgan; Wheeler, Amanda J.

    2010-01-01

    Indoor concentrations of air pollutants (benzene, toluene, formaldehyde, acetaldehyde, acrolein, nitrogen dioxide, particulate matter, elemental carbon and ozone) were measured in residences in Regina, Saskatchewan, Canada. Data were collected in 106 homes in winter and 111 homes in summer of 2007, with 71 homes participating in both seasons. In addition, data for relative humidity, temperature, air exchange rates, housing characteristics and occupants’ activities during sampling were collected. Multiple linear regression analysis was used to construct season-specific models for the air pollutants. Where smoking was a major contributor to indoor concentrations, separate models were constructed for all homes and for those homes with no cigarette smoke exposure. The housing characteristics and occupants’ activities investigated in this study explained between 11% and 53% of the variability in indoor air pollutant concentrations, with ventilation, age of home and attached garage being important predictors for many pollutants. PMID:20948949

  7. Indoor/outdoor relationships of bioaerosol concentrations in a retirement home and a school dormitory.

    PubMed

    Faridi, Sasan; Hassanvand, Mohammad Sadegh; Naddafi, Kazem; Yunesian, Masud; Nabizadeh, Ramin; Sowlat, Mohammad Hossein; Kashani, Homa; Gholampour, Akbar; Niazi, Sadegh; Zare, Ahad; Nazmara, Shahrokh; Alimohammadi, Mahmood

    2015-06-01

    The concentrations of bacterial and fungal bioaerosols were measured in a retirement home and a school dormitory from May 2012 to May 2013. In the present work, two active and passive methods were used for bioaerosol sampling. The results from the present work indicated that Bacillus spp., Micrococcus spp., and Staphylococcus spp. were the dominant bacterial genera, while the major fungal genera were Penicillium spp., Cladosporium spp., and Aspergillus spp. The results also indicated that the indoor-to-outdoor (I/O) ratios for total bacteria were 1.77 and 1.44 in the retirement home and the school dormitory, respectively; the corresponding values for total fungal spores were 1.23 and 1.08. The results suggested that in addition to outdoor sources, indoor sources also played a significant role in emitting bacterial and fungal bioaerosols in the retirement home and the school dormitory indoor.

  8. Autonomy and Housing Accessibility Among Powered Mobility Device Users

    PubMed Central

    Brandt, Åse; Lexell, Eva Månsson; Iwarsson, Susanne

    2015-01-01

    OBJECTIVE. To describe environmental barriers, accessibility problems, and powered mobility device (PMD) users’ autonomy indoors and outdoors; to determine the home environmental barriers that generated the most housing accessibility problems indoors, at entrances, and in the close exterior surroundings; and to examine personal factors and environmental components and their association with indoor and outdoor autonomy. METHOD. This cross-sectional study was based on data collected from a sample of 48 PMD users with a spinal cord injury (SCI) using the Impact of Participation and Autonomy and the Housing Enabler instruments. Descriptive statistics and logistic regression were used. RESULTS. More years living with SCI predicted less restriction in autonomy indoors, whereas more functional limitations and accessibility problems related to entrance doors predicted more restriction in autonomy outdoors. CONCLUSION. To enable optimized PMD use, practitioners must pay attention to the relationship between client autonomy and housing accessibility problems. PMID:26356666

  9. Indoor air - assessment: Methods of analysis for environmental carcinogens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peterson, M.R.; Naugle, D.F.; Berry, M.A.

    1990-06-01

    The monograph describes, in a general way, published sampling procedures and analytical approaches for known and suspected carcinogens. The primary focus is upon carcinogens found in indoor air, although the methods described are applicable to other media or environments. In cases where there are no published methods for a particular pollutant in indoor air, methods developed for the workplace and for ambient air are included since they should be adaptable to indoor air. Known and suspected carcinogens have been grouped into six categories for the purposes of this and related work. The categories are radon, asbestos, organic compounds, inorganic species,more » particles, and non-ionizing radiation. Some methods of assessing exposure that are not specific to any particular pollutant category are covered in a separate section. The report is the fifth in a series of EPA/Environmental Criteria and Assessment Office Monographs.« less

  10. [Air quality in schools - classroom levels of carbon dioxide (CO2), volatile organic compounds (VOC), aldehydes, endotoxins and cat allergen].

    PubMed

    Fromme, H; Heitmann, D; Dietrich, S; Schierl, R; Körner, W; Kiranoglu, M; Zapf, A; Twardella, D

    2008-02-01

    Children are assumed to be more vulnerable to health hazards and spend a large part of their time in schools. To assess the exposure situation in this microenvironment, we evaluated the indoor air quality in winter 2004/5 in 92 classrooms, and in 75 classrooms in summer 2005 in south Bavaria, Germany. Indoor air climate parameters (temperature, relative humidity), carbon dioxide (CO2) and various volatile organic compounds, aldehydes and ketones were measured. Additionally, cat allergen (Fel d1) and endotoxin (LAL-test) were analysed in the settled dust of school rooms. Data on room and building characteristics were collected by use of a standardised form. Only data collected during teaching hours were considered in analysis. The median indoor CO2 concentration in the classrooms ranged in the winter and summer period from 598 to 4 172 ppm and 480 to 1 875 ppm, respectively. While during the winter period in 92% of the classrooms the CO2 daily medians went above 1 000 ppm, the percentage of classrooms with increased CO2 concentration fell to 28% in summer. In winter, in 60% of classes the daily median CO2 concentration exceeded 1 500 ppm, while in summer this threshold was reached by only 9%. A high concentration of CO2 was associated with a high number of pupils, a low room surface area and a low room volume. The levels of total volatile organic compounds (TVOC) in classrooms ranged between 110 and 1 000 microg/m3 (median in winter 345 microg/m3, in summer 260 microg/m3). Acetone, formaldehyde and acetaldehyde were measured in concentrations from 14.0 to 911 microg/m3, from 3.1 to 46.1 microg/m3, and from 2.9 to 78 microg/m3, respectively. The other aldehydes were detected in minor amounts only. The median Fel d1 level in winter was 485 ng/g dust (20 to 45 160 ng/g) and in summer it was 417 ng/g (40-7 470 ng/g). We observed no marked differences between the two sampling periods and between smooth floors and rooms with carpeted floors. No differences were found according to room surface area and room volume. The median endotoxin contents in winter and summer were 19.7 EU/mg dust (6.6 to 154 EU/mg) and 32.2 EU/mg (9.6 to 219 EU/mg), respectively. The levels varied significantly between the sampling periods, but were independent of room surface area, room volume and surface floorings. Overall the results of VOC, aldehydes, ketones and endotoxin indicate, in general, a low exposure level in classrooms. The observed concentrations of cat allergens should be considered as a meaningful exposure route and thus could be tackled within preventive programs.

  11. [Environmental surveillance of a sample of indoor swimming pools from Emilia Romagna region: microclimate characteristics and chemical parameters, particularly disinfection by products, in pool waters].

    PubMed

    Fantuzzi, G; Righi, E; Predieri, G; Giacobazzi, P; Mastroianni, K; Aggazzotti, G

    2010-01-01

    The aim of the present study was to investigate the environmental and healthy aspects from a representative sample of indoor swimming pools located in the Emilia Romagna region. During the sampling sessions, the occupational environment was evaluated in terms of microclimate parameters and thermal comfort/discomfort conditions. Moreover the chemical risk was assessed by analyzing from the pool water the presence of disinfection by-products (DBPs), such as: trihalomethanes (THMs), haloacetic acids (HAAs), chlorite, chlorate and bromate. The analytical results are in agreement with the Italian legislation (Accordo Stato-Regioni; 2003) even if in some of the sampled indoor swimming pools, the dosed combined chlorine levels, were greater than the Italian limit. With the regard to the microclimate conditions evaluation, the considered thermal indices, Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD%), described a satisfactory occupational environment. Among DBPs, the THMs mean levels (41.4 +/- 30.0 microg/l) resulted close to the values of the current Italian drinking water legislation, and seem to not represent an health issue. The pool waters chlorate levels (range: 5 - 19537 microg/l) need further investigations as recent epidemiological studies on drinking water hypothesized a potential genotoxicity effect of these compounds which are involved in cellular oxidative processes.

  12. Organophosphorus flame retardants and plasticizers in air from various indoor environments.

    PubMed

    Marklund, Anneli; Andersson, Barbro; Haglund, Peter

    2005-08-01

    Eleven organophosphorus compounds (OPs) that are used as plasticizers and flame retardants were analysed in duplicate samples of indoor air from 17 domestic and occupational environments. Solid-phase extraction (SPE) columns were used as adsorbents and analysis was performed using GC with a nitrogen phosphorus selective detector. The total amounts of OPs in the air samples ranged between 36 and 950 ng m(-3); tris(chloropropyl) phosphate (TCPP) and tris(2-chloroethyl) phosphate (TCEP) being the most abundant (0.4 to 730 ng m(-3)), followed by tributyl phosphate (0.5-120 ng m(-3)). Public buildings tended to have about 3-4 times higher levels of OPs than domestic buildings. The relative amounts of individual OPs varied between the sites and generally reflected the building materials, furniture and consumer products used in the sampled environments. Potential sources of these compounds include, inter alia, acoustic ceilings, upholstered furniture, wall coverings, floor polish and polyvinylchloride floor coverings. A correlation was observed between the TCEP concentrations in the air in the sampled environments and previously reported concentrations in dust, but no such correlation was seen for the heavier and less volatile tris(2-butoxyethyl) phosphate (TBEP). Based on estimated amounts of indoor air inhaled and dust ingested, adults and children in the sampled environments would be exposed to up to 5.8 microg kg(-1) day(-1) and 57 microg kg(-1) day(-1) total OPs, respectively.

  13. Household pesticide contamination from indoor pest control applications in urban low-income public housing dwellings: a community-based participatory research.

    PubMed

    Lu, Chensheng; Adamkiewicz, Gary; Attfield, Kathleen R; Kapp, Michaela; Spengler, John D; Tao, Lin; Xie, Shao Hua

    2013-02-19

    We designed this community-based participatory research (CBPR) project aiming to generate evidence-based research results to encourage residents living in urban low-income public housing dwellings engaging in a community-wide integrated pest management (IPM) program with the intention to improve their health and quality of life, as well as household conditions. We enrolled 20 families and their children in this study in which we utilized environmental exposure assessment (surface wipe and indoor air) tools to quantitatively assessing residential pesticide exposure in young children before the implementation of an IPM program. We analyzed those samples for 19 organophosphate (OP) and pyrethroid pesticides. The most commonly detected pesticides were pyrethroids, particularly permethrin and cypermethrin with average concentrations of 2.47 and 3.87 μg/m(2), respectively. In many dwellings, we detected OPs, which are no longer available on the market; however, their levels are significantly lower than those of pyrethroids. None of the 20 families was free from pesticide contamination in their households, and pesticides were commonly detected in living room and children's bedroom. The correlation among household hygienic conditions, the sighting of live pests/pest debris, and the degree of indoor pesticide contamination highlights the failure of conventional chemical-based applications for pest controls. The results from the current study, as well as other recent studies, conducted in low-income public housing, child care centers, and randomly selected homes in the U.S. should accentuate the need for alternative pest management programs that incorporate safer and more sustainable protocols for pest controls.

  14. HOUSEHOLD PESTICIDE CONTAMINATION FROM INDOOR PEST CONTROL APPLICATIONS IN URBAN LOW-INCOME PUBLIC HOUSING DWELLINGS: A COMMUNITY-BASED PARTICIPATORY RESEARCH

    PubMed Central

    Adamkiewicz, Gary; Attfield, Kathleen; Kapp, Michaela; Spengler, John D; Tao, Lin; Xie, Shao Hua

    2013-01-01

    We designed this community-based participatory research (CBPR) project aiming to generate evidence-based research results in order to encourage residents living in urban low-income public housing dwellings engaging in a community-wide integrated pest management (IPM) program with the intention to improve their health and quality of life, as well as household conditions. We enrolled 20 families and their children in this study in which we utilized environmental exposure assessment (surface wipe and indoor air) tools to quantitatively assessing residential pesticide exposure in young children before the implementation of an IPM program. We analyzed those samples for 19 organophosphate (OP) and pyrethroid pesticides. The most commonly detected pesticides were pyrethroids, particularly permethrin and cypermethrin with average concentrations of 2.47 and 3.87 µg/m2, respectively. In many dwellings, we detected OPs, which are no longer available on the market, however, their levels are significantly lower than those of pyrethroids. None of the 20 families was free from pesticide contamination in their households, and pesticides were commonly detected in living room and children’s bedroom. The correlation among household hygienic conditions, the sighting of live pests/pest debris, and the degree of indoor pesticide contamination highlights the failure of conventional chemical-based applications for pest controls. The results from the current study, as well as other recent studies, conducted in low-income public housing, child care centers, and randomly selected homes in the U.S. should accentuate the need for alternative pest management programs that incorporate safer and more sustainable protocols for pest controls. PMID:23363037

  15. Behavioral thermoregulation in a group of zoo-housed colobus monkeys (Colobus guereza).

    PubMed

    Wark, Jason D; Kuhar, Christopher W; Lukas, Kristen E

    2014-01-01

    Although wild primates are known to modify behavior in response to thermal stress, less is known about behavioral thermoregulation in zoo-housed primates. Zoo exhibits expose individuals to unique thermal environments and may constrain the thermoregulatory strategies available to individual animals. In this study, we observed a group of seven colobus monkeys (Colobus guereza) living on a concrete "Monkey Island" style exhibit that featured limited shade and limited arboreal space. Behaviors were recorded using continuous focal animal sampling (n = 63 days, 97.7 hr). Logistic regression revealed 23°C was the temperature at which monkeys began resting more in shade than in sun. When temperatures exceeded 23°C, animals spent more time in open sitting postures with limbs extended from the body; sat less frequently in closed, hunched postures; spent more time in social contact; and performed more self-directed behaviors. Exhibit use also shifted under higher temperatures, with more time spent in areas with shade and lower surface temperatures. Lastly, when provided with access to an indoor holding area, the colobus monkeys spent more than half the time indoors when temperatures exceeded 23°C, yet only 10% of their time indoors when the temperature was below this value. Although postural changes have been reported in wild colobus, the postural and other behavioral changes observed in the current study occurred at temperatures lower than expected based on the published thermoneutral zone of colobus monkeys and highlight the importance of considering the specific thermoregulatory responses of zoo animals. © 2014 Wiley Periodicals, Inc.

  16. Moldy buildings, health of their occupants and fungal prevention.

    PubMed

    Mihinova, D; Pieckova, E

    2012-01-01

    Microscopic fungi are important biological pollutants in the indoor environment, they are spread generally: on building materials, carpets, ceiling tiles, insulations, any surfaces, wallpapers, or in heating, ventilation, and air conditioning systems. Molds are able to grow on any materials, as long as moisture and oxygen are available. Exposure to fungi in indoor environments (esp. in water-damaged buildings) can cause adverse health effects, such as allergy, asthma, hypersensitivity pneumonia, mucous membrane irritation, different toxic effects, or even mycoses (in immunocompromised individuals) - alone or in combination. As serious adverse health effects could be caused antifungal prevention is an absolute need.This review article summarizes the occurrence of fungi in the indoor environment of buildings and their contribution to occupants´ health problems, and preventive measures against molds (Tab. 1, Fig. 1, Ref. 48).

  17. The effect of proximity to major roads on indoor air quality in typical Australian dwellings

    NASA Astrophysics Data System (ADS)

    Lawson, Sarah J.; Galbally, Ian E.; Powell, Jennifer C.; Keywood, Melita D.; Molloy, Suzie B.; Cheng, Min; Selleck, Paul W.

    2011-04-01

    An Indoor Air Quality Study of residential dwellings was carried out in Melbourne, Australia, and a subset of the data was analysed to investigate the effect of proximity to major roads on indoor air quality (IAQ). Seven-day measurements of PM 10, NO 2, benzene, toluene, ethylbenzene and xylenes, along with continuous CO and PM 2.5 measurements were utilised. The measurements were made indoors and outdoors in 27 dwellings; 15 Near Road (<50 m from a major road) and 12 Far Road (>300 m from a major road). Dwellings were sampled for one week each in Winter/Spring 2008 and Summer/Autumn 2009, over an eight month period. Analysis of 7-day measurements showed that NO 2 and toluene were elevated at the 5% significance level both indoors and outdoors at Near Road Dwellings compared to Far Road Dwellings. Indoor/Outdoor (I/O) ratios of NO 2 and toluene were not significantly different between Near and Far Road dwellings giving no evidence of any anomalous dominant indoor source for NO 2 and toluene in Near Road dwellings. Indoor NO 2 was significantly correlated to gas stovetop and oven use in both Near and Far Road dwellings. In the absence of gas cooking, indoor NO 2 was elevated in Near Road dwellings relative to Far Road dwellings by approximately 4 ppb and this can be attributed to infiltration of outdoor air. I/O ratios for NO 2 were <1 for Near and Far Road dwellings, indicating that outdoor NO 2, and hence roadway emissions can potentially contribute a significant proportion to the indoor NO 2 concentration. Mean toluene I/O ratios were >2 indicating that indoor sources dominate with minor contribution from outdoors. Hence the relative contribution of roadways to indoor NO 2 is potentially greater than the relative contribution of roadways to indoor toluene. Findings elsewhere suggest that a similar outdoor enhancement of traffic related NO 2 (˜5 ppb) increases risk of lung cancer and childhood asthma ( Brauer et al., 2000; Nyberg et al., 2000). A simple conceptual model indicated spatial and temporal variance in the concentrations was the biggest limitation in detecting roadway influence outside Near Road dwellings for PM 10, PM 2.5 and NO 2 while measurement uncertainty was also important for CO.

  18. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR USE OF THE ACTIVE VOC SAMPLER FOR THE COLLECTION OF AIRBORNE VOCS AT FIXED INDOOR AND OUTDOOR SITES (UA-F-11.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used to collect indoor and outdoor air samples for the determination of selected volatile organic compounds (VOC's) using a pump to draw air through a Carbotrap Sampler. Volatile organic compounds (VOCs) present in the air are p...

  19. NHEXAS PHASE I MARYLAND STUDY--QA ANALYTICAL RESULTS FOR PESTICIDES IN REPLICATE SAMPLES

    EPA Science Inventory

    The Pesticides in Replicates data set contains the analytical results of measurements of up to 10 pesticides in 68 replicate (duplicate) samples from 41 households. Measurements were made in samples of indoor air, dust, soil, drinking water, food, and beverages. Duplicate sampl...

  20. Atmospheric concentrations of polybrominated diphenyl ethers at near-source sites.

    PubMed

    Cahill, Thomas M; Groskova, Danka; Charles, M Judith; Sanborn, James R; Denison, Michael S; Baker, Lynton

    2007-09-15

    Concentrations of polybrominated diphenyl ethers (PBDEs) were determined in air samples from near suspected sources, namely an indoors computer laboratory, indoors and outdoors at an electronics recycling facility, and outdoors at an automotive shredding and metal recycling facility. The results showed that (1) PBDE concentrations in the computer laboratorywere higherwith computers on compared with the computers off, (2) indoor concentrations at an electronics recycling facility were as high as 650,000 pg/m3 for decabromodiphenyl ether (PBDE 209), and (3) PBDE 209 concentrations were up to 1900 pg/m3 at the downwind fenceline at an automotive shredding/metal recycling facility. The inhalation exposure estimates for all the sites were typically below 110 pg/kg/day with the exception of the indoor air samples adjacent to the electronics shredding equipment, which gave exposure estimates upward of 40,000 pg/kg/day. Although there were elevated inhalation exposures at the three source sites, the exposure was not expected to cause adverse health effects based on the lowest reference dose (RfD) currently in the Integrated Risk Information System (IRIS), although these RfD values are currently being re-evaluated by the U.S. Environmental Protection Agency. More research is needed on the potential health effects of PBDEs.

  1. Characterization of Viral Load, Viability and Persistence of Influenza A Virus in Air and on Surfaces of Swine Production Facilities.

    PubMed

    Neira, Victor; Rabinowitz, Peter; Rendahl, Aaron; Paccha, Blanca; Gibbs, Shawn G; Torremorell, Montserrat

    2016-01-01

    Indirect transmission of influenza A virus (IAV) in swine is poorly understood and information is lacking on levels of environmental exposure encountered by swine and people during outbreaks of IAV in swine barns. We characterized viral load, viability and persistence of IAV in air and on surfaces during outbreaks in swine barns. IAV was detected in pigs, air and surfaces from five confirmed outbreaks with 48% (47/98) of oral fluid, 38% (32/84) of pen railing and 43% (35/82) of indoor air samples testing positive by IAV RT-PCR. IAV was isolated from air and oral fluids yielding a mixture of subtypes (H1N1, H1N2 and H3N2). Detection of IAV RNA from air was sustained during the outbreaks with maximum levels estimated between 7 and 11 days from reported onset. Our results indicate that during outbreaks of IAV in swine, aerosols and surfaces in barns contain significant levels of IAV potentially representing an exposure hazard to both swine and people.

  2. Exposure of Children to Ultrafine Particles in Primary Schools in Portugal.

    PubMed

    Rufo, João Cavaleiro; Madureira, Joana; Paciência, Inês; Slezakova, Klara; Pereira, Maria do Carmo; Pereira, Cristiana; Teixeira, João Paulo; Pinto, Mariana; Moreira, André; Fernandes, Eduardo de Oliveira

    2015-01-01

    Children spend a large part of their time at schools, which might be reflected as chronic exposure. Ultrafine particles (UFP) are generally associated with a more severe toxicity compared to fine and coarse particles, due to their ability to penetrate cell membranes. In addition, children tend to be more susceptible to UFP-mediated toxicity compared to adults, due to various factors including undeveloped immune and respiratory systems and inhalation rates. Thus, the purpose of this study was to determine indoor UFP number concentrations in Portuguese primary schools. Ultrafine particles were sampled between January and March 2014 in 10 public primary schools (35 classrooms) located in Porto, Portugal. Overall, the average indoor UFP number concentrations were not significantly different from outdoor concentrations (8.69 × 10(3) vs. 9.25 × 10(3) pt/cm(3), respectively; considering 6.5 h of indoor occupancy). Classrooms with distinct characteristics showed different trends of indoor UFP concentrations. The levels of carbon dioxide were negatively correlated with indoor UFP concentrations. Occupational density was significantly and positively correlated with UFP concentrations. Although the obtained results need to be interpreted with caution since there are no guidelines for UFP levels, special attention needs to be given to source control strategies in order to reduce major particle emissions and ensure good indoor air quality.

  3. Volatile organic compounds in fourteen U.S. retail stores.

    PubMed

    Nirlo, E L; Crain, N; Corsi, R L; Siegel, J A

    2014-10-01

    Retail buildings have a potential for both short-term (customer) and long-term (occupational) exposure to indoor pollutants. However, little is known about volatile organic compound (VOC) concentrations in the retail sector and influencing factors, such as ventilation, in-store activities, and store type. We measured VOC concentrations and ventilation rates in 14 retail stores in Texas and Pennsylvania. With the exception of formaldehyde and acetaldehyde, VOCs were present in retail stores at concentrations well below health guidelines. Indoor formaldehyde concentrations ranged from 4.6 ppb to 67 ppb. The two mid-sized grocery stores in the sample had the highest levels of ethanol and acetaldehyde, with concentrations up to 2.6 ppm and 92 ppb, respectively, possibly due to the preparation of dough and baking activities. Indoor-to-outdoor concentration ratios indicated that indoor sources were the main contributors to indoor VOC concentrations for the majority of compounds. There was no strong correlation between ventilation and VOC concentrations across all stores. However, increasing the air exchange rates at two stores led to lower indoor VOC concentrations, suggesting that ventilation can be used to reduce concentrations for some specific stores. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Synthetic turf field investigation in Connecticut.

    PubMed

    Simcox, Nancy J; Bracker, Anne; Ginsberg, Gary; Toal, Brian; Golembiewski, Brian; Kurland, Tara; Hedman, Curtis

    2011-01-01

    The primary purpose of this study was to characterize the concentrations of volatile organic compounds (VOC), semivolatile organic compounds (SVOC), rubber-related chemicals such as benzothiazole (BZT) and nitrosamine, and particulate matter (PM(10)) in air at synthetic turf crumb rubber fields. Both new and older fields were evaluated under conditions of active use. Three types of fields were targeted: four outdoor crumb rubber fields, one indoor facility with crumb rubber turf, and an outdoor natural grass field. Background samples were collected at each field on grass. Personal air sampling was conducted for VOC, BZT, nitrosamines, and other chemicals. Stationary air samples were collected at different heights to assess the vertical profile of release. Air monitoring for PM(10) was conducted at one height. Bulk samples of turf grass and crumb rubber were analyzed, and meteorological data were recorded. Results showed that personal concentrations were higher than stationary concentrations and were higher on turf than in background samples for certain VOC. In some cases, personal VOC concentrations from natural grass fields were as high as those on turf. Naphthalene, BZT, and butylated hydroxytoluene (BHT) were detected in greater concentration at the indoor field compared to the outdoor fields. Nitrosamine air levels were below reporting levels. PM(10) air concentrations were not different between on-field and upwind locations. All bulk lead (Pb) samples were below the public health target of 400 ppm. More research is needed to better understand air quality at indoor facilities. These field investigation data were incorporated into a separate human health risk assessment.

  5. Chemical compositions of subway particles in Seoul, Korea determined by a quantitative single particle analysis.

    PubMed

    Kang, Sunni; Hwang, HeeJin; Park, YooMyung; Kim, HyeKyoung; Ro, Chul-Un

    2008-12-15

    A novel single particle analytical technique, low-Z particle electron probe X-ray microanalysis, was applied to characterize seasonal subway samples collected at a subway station in Seoul, Korea. For all 8 samples collected twice in each season, 4 major types of subway particles, based on their chemical compositions, are significantly encountered: Fe-containing; soil-derived; carbonaceous; and secondary nitrate and/or sulfate particles. Fe-containing particles are generated indoors from wear processes at rail-wheel-brake interfaces while the others may be introduced mostly from the outdoor urban atmosphere. Fe-containing particles are the most frequently encountered with relative abundances in the range of 61-79%. In this study, it is shown that Fe-containing subway particles almost always exist either as partially or fully oxidized forms in underground subway microenvironments. Their relative abundances of Fe-containing particles increase as particle sizes decrease. Relative abundances of Fe-containing particles are higher in morning samples than in afternoon samples because of heavier train traffic in the morning. In the summertime samples, Fe-containing particles are the most abundantly encountered, whereas soil-derived and nitrate/sulfate particles are the least encountered, indicating the air-exchange between indoor and outdoor environments is limited in the summer, owing to the air-conditioning in the subway system. In our work, it was observed that the relative abundances of the particles of outdoor origin vary somewhat among seasonal samples to a lesser degree, reflecting that indoor emission sources predominate.

  6. Characterization of particle number concentrations and PM2.5 in a school: influence of outdoor air pollution on indoor air.

    PubMed

    Guo, Hai; Morawska, Lidia; He, Congrong; Zhang, Yanli L; Ayoko, Godwin; Cao, Min

    2010-07-01

    The impact of air pollution on school children's health is currently one of the key foci of international and national agencies. Of particular concern are ultrafine particles which are emitted in large quantities, contain large concentrations of toxins and are deposited deeply in the respiratory tract. In this study, an intensive sampling campaign of indoor and outdoor airborne particulate matter was carried out in a primary school in February 2006 to investigate indoor and outdoor particle number (PN) and mass concentrations (PM(2.5)), and particle size distribution, and to evaluate the influence of outdoor air pollution on the indoor air. For outdoor PN and PM(2.5), early morning and late afternoon peaks were observed on weekdays, which are consistent with traffic rush hours, indicating the predominant effect of vehicular emissions. However, the temporal variations of outdoor PM(2.5) and PN concentrations occasionally showed extremely high peaks, mainly due to human activities such as cigarette smoking and the operation of mower near the sampling site. The indoor PM(2.5) level was mainly affected by the outdoor PM(2.5) (r = 0.68, p < 0.01), whereas the indoor PN concentration had some association with outdoor PN values (r = 0.66, p < 0.01) even though the indoor PN concentration was occasionally influenced by indoor sources, such as cooking, cleaning and floor polishing activities. Correlation analysis indicated that the outdoor PM(2.5) was inversely correlated with the indoor to outdoor PM(2.5) ratio (I/O ratio; r = -0.49, p < 0.01), while the indoor PN had a weak correlation with the I/O ratio for PN (r = 0.34, p < 0.01). The results showed that occupancy did not cause any major changes to the modal structure of particle number and size distribution, even though the I/O ratio was different for different size classes. The I/O curves had a maximum value for particles with diameters of 100-400 nm under both occupied and unoccupied scenarios, whereas no significant difference in I/O ratio for PM(2.5) was observed between occupied and unoccupied conditions. Inspection of the size-resolved I/O ratios in the preschool centre and the classroom suggested that the I/O ratio in the preschool centre was the highest for accumulation mode particles at 600 nm after school hours, whereas the average I/O ratios of both nucleation mode and accumulation mode particles in the classroom were much lower than those of Aitken mode particles. The findings obtained in this study are useful for epidemiological studies to estimate the total personal exposure of children, and to develop appropriate control strategies for minimising the adverse health effects on school children.

  7. Comparison of Conventional Varnishes with Nanolacke UV Varnish With Respect to Hardness and Adhesion Durability

    PubMed Central

    Kaygin, Bulent; Akgun, Emre

    2008-01-01

    The long-term durability of varnished wooden surfaces used in either indoors or outdoors environments depends on the resistance of varnish layers on these surfaces against potential physical, mechanical and chemical effects to which they may be exposed. In this study, “Nanolacke ultraviolet varnish”, developed by a Turkish dying and varnish industry company and widely accepted as a 21st century technology has been compared to other conventional varnish systems widely used in the industry in terms of dry film resistance properties. In this study, cellulosic, polyurethane, polyester, synthetic and Nanolacke ultraviolet varnish have been applied on beech (Fagus orientalis L.) and oak (Quercus robur L.) wood samples which had been prepared according to the industry standards. Then, the hardness and adhesion resistance of these layers have been determined according to ASTM D 4366 and ASTM D 3359-2 standards, respectively. PMID:19325763

  8. Assessment of Indoor and Outdoor PM Species at Schools and Residences in a High-Altitude Ecuadorian Urban Center

    PubMed Central

    Raysoni, Amit U.; Armijos, Rodrigo X.; Weigel, M. Margaret; Montoya, Teresa; Eschanique, Patricia; Racines, Marcia; Li, Wen-Whai

    2016-01-01

    An air monitoring campaign to assess children’s environmental exposures in schools and residences, both indoors and outdoors, was conducted in 2010 in three low-income neighborhoods in Z1(north), Z2(central), and Z3(southeast) zones of Quito, Ecuador - a major urban center of 2.2 million inhabitants situated 2850 meters above sea level in a narrow mountainous basin. Z1 zone, located in northern Quito, historically experienced emissions from quarries and moderate traffic. Z2 zone was influenced by heavy traffic in contrast to Z3 zone which experienced low traffic densities. Weekly averages of PM samples were collected at schools (one in each zone) and residences (Z1=47, Z2=45, and Z3=41) every month, over a twelve-month period at the three zones. Indoor PM2.5 concentrations ranged from 10.6±4.9 μg/m3 (Z1 school) to 29.0±30.5 μg/m3 (Z1 residences) and outdoor PM2.5 concentrations varied from 10.9±3.2 μg/m3 (Z1 school) to 14.3±10.1 μg/m3 (Z2 residences), across the three zones. The lowest values for PM10–2.5 for indoor and outdoor microenvironments were recorded at Z2 school, 5.7±2.8 μg/m3 and 7.9±2.2 μg/m3, respectively. Outdoor school PM concentrations exhibited stronger associations with corresponding indoor values making them robust proxies for indoor exposures in naturally ventilated Quito public schools. Correlation analysis between the school and residential PM size fractions and the various pollutant and meteorological parameters from central ambient monitoring (CAM) sites suggested varying degrees of temporal relationship. Strong positive correlation was observed for outdoor PM2.5 at Z2 school and its corresponding CAM site (r=0.77) suggesting common traffic related emissions. Spatial heterogeneity in PM2.5 concentrations between CAM network and sampled sites was assessed using Coefficient of Divergence (COD) analysis. COD values were lower when CAM sites were paired with outdoor measurements (< 0.2) and higher when CAM and indoor values were compared (> 0.2), suggesting that CAM network in Quito may not represent actual indoor exposures. PMID:27149144

  9. The impact of heavy metals from environmental tobacco smoke on indoor air quality as determined by Compton suppression neutron activation analysis.

    PubMed

    Landsberger, S; Wu, D

    1995-12-01

    The method of instrumental neutron activation analysis (NAA) has been improved for air filter samples in the determination of low level heavy metals in indoor air. By using the techniques of epithermal neutron irradiation in conjunction with Compton suppression, the detection limits of cadmium, arsenic and antimony measurements have been dramatically reduced to 2 ng for Cd, 0.2 ng for As, and 0.03 ng for Sb. The determination of these heavy metals in particulate material generated from cigarette smoking in indoor environments has been conducted. Other elements, Br, Cl, Na, K, Zn were also found at elevated levels.

  10. Correlates of Persistent Smoking in Bars Subject to Smokefree Workplace Policy

    PubMed Central

    Moore, Roland S.; Lee, Juliet P.; Martin, Scott E.; Todd, Michael; Chu, Bong Chul

    2009-01-01

    This study’s goal was to characterize physical and social environments of stand-alone bars associated with indoor smoking despite California’s smokefree workplace law. In a random sample of 121 stand-alone bars in San Francisco, trained observers collected data on patrons, staff, neighborhood, indoor settings and smoking behaviors. Using bivariate (chi-square) and hierarchical linear modeling analyses, we identified four correlates of patrons’ indoor smoking: 1) bars serving predominantly Asian or Irish patrons, 2) ashtrays, 3) bartender smoking, and 4) female bartenders. Public health officials charged with enforcement of smokefree bar policies may need to attend to social practices within bars, and heighten perceptions of consistent enforcement of smokefree workplace laws. PMID:19440522

  11. Childhood hypersensitivity pneumonitis associated with fungal contamination of indoor hydroponics.

    PubMed

    Engelhart, Steffen; Rietschel, Ernst; Exner, Martin; Lange, Lars

    2009-01-01

    Childhood hypersensitivity pneumonitis (HP) is often associated with exposure to antigens in the home environment. We describe a case of HP associated with indoor hydroponics in a 14-year-old girl. Water samples from hydroponics revealed Aureobasidium pullulans as the dominant fungal micro-organism (10(4)CFU/ml). The diagnosis is supported by the existence of serum precipitating antibodies against A. pullulans, lymphocytic alveolitis on bronchoalveolar lavage (BAL) fluid, a corresponding reaction on a lung biopsy, and the sustained absence of clinical symptoms following the removal of hydroponics from the home. We conclude that hydroponics should be considered as potential sources of fungal contaminants when checking for indoor health complaints.

  12. Thermal Transmission through Existing Building Enclosures: Destructive Monitoring in Intermediate Layers versus Non-Destructive Monitoring with Sensors on Surfaces.

    PubMed

    Echarri, Víctor; Espinosa, Almudena; Rizo, Carlos

    2017-12-08

    Opaque enclosures of buildings play an essential role in the level of comfort experienced indoors and annual energy demand. The impact of solar radiation and thermal inertia of the materials that make up the multi-layer enclosures substantially modify thermal transmittance behaviour of the enclosures. This dynamic form of heat transfer, additionally affected by indoor HVAC systems, has a substantial effect on the parameters that define comfort. It also has an impact on energy demand within a daily cycle as well as throughout a one-year use cycle. This study describes the destructive monitoring of an existing block of flats located in Alicante. Once the enclosure was opened, sensors of temperature (PT100), air velocity, and relative humidity were located in the different layers of the enclosure, as well as in the interior and exterior surfaces. A pyranometer was also installed to measure solar radiation levels. A temperature data correction algorithm was drawn up to address irregularities produced in the enclosure. The algorithm was applied using a Raspberry Pi processor in the data collection system. The comparative results of temperature gradients versus non-destructive monitoring systems are presented, providing measures of the transmittance value, surface temperatures and indoor and outdoor air temperatures. This remote sensing system can be used in future studies to quantify and compare the energy savings of different enclosure construction solutions.

  13. Thermal Transmission through Existing Building Enclosures: Destructive Monitoring in Intermediate Layers versus Non-Destructive Monitoring with Sensors on Surfaces

    PubMed Central

    Echarri, Víctor; Espinosa, Almudena; Rizo, Carlos

    2017-01-01

    Opaque enclosures of buildings play an essential role in the level of comfort experienced indoors and annual energy demand. The impact of solar radiation and thermal inertia of the materials that make up the multi-layer enclosures substantially modify thermal transmittance behaviour of the enclosures. This dynamic form of heat transfer, additionally affected by indoor HVAC systems, has a substantial effect on the parameters that define comfort. It also has an impact on energy demand within a daily cycle as well as throughout a one-year use cycle. This study describes the destructive monitoring of an existing block of flats located in Alicante. Once the enclosure was opened, sensors of temperature (PT100), air velocity, and relative humidity were located in the different layers of the enclosure, as well as in the interior and exterior surfaces. A pyranometer was also installed to measure solar radiation levels. A temperature data correction algorithm was drawn up to address irregularities produced in the enclosure. The algorithm was applied using a Raspberry Pi processor in the data collection system. The comparative results of temperature gradients versus non-destructive monitoring systems are presented, providing measures of the transmittance value, surface temperatures and indoor and outdoor air temperatures. This remote sensing system can be used in future studies to quantify and compare the energy savings of different enclosure construction solutions. PMID:29292781

  14. Comparison of Cultural and Molecular Fecal Indicator Measurements in Surface Water and Periphyton Biofilms in Artificial Streams

    EPA Science Inventory

    Studies suggest that periphyton in streambeds can harbor fecal indicator bacteria (FIB) and, under certain circumstances, can be transferred from the periphyton biofilm into the surface water. An indoor mesocosm study was conducted at the U.S. Environmental Protection Agency Expe...

  15. Carpet vs. Hard Surface Floors: Studies Compare Health Effects of Each.

    ERIC Educational Resources Information Center

    Schmidt, Edward A.

    1994-01-01

    This article, third in a three-part series of articles that discuss indoor air quality (IAQ) issues affecting schools, looks at studies that compare the health effect of carpet and hard surface floors. Concludes that carpet is appropriate for use in schools when it is properly maintained. (MLF)

  16. Microbiological assessment of indoor air of a teaching hospital in Nigeria.

    PubMed

    Awosika, S A; Olajubu, F A; Amusa, N A

    2012-06-01

    To investigate the quality of indoor air of different wards and units of Olabisi Onabanjo University Teaching Hospital, Sagamu, to ascertain their contribution to infection rate in the hospital. The microbial quality of indoor air of nine wards/units of Olabisi Onabanjo University Teaching Hospital, Sagamu, Nigeria was conducted. Sedimentation technique using open Petri-dishes containing different culture media was employed and samplings were done twice daily, one in the morning shortly after cleaning and before influx of people/patients into the wards/units and the other in the evening when a lot of activities would have taken place in these wards. Isolates were identified according to standard methods. Results showed that there was a statistically significant difference (χ(2) = 6.016 7) in the bacteria population of the different sampling time whereas it was not so for fungi population (χ(2) = 0.285 7). Male medical ward (MMW) and male surgical general (MSG) recorded the highest bacterial and fungal growth while the operating theatre (OT) was almost free of microbial burden. The bacteria isolates were Staphylococcus aureus, Klebsiella sp., Bacillus cereus, Bacillus subtilis, Streptococcus pyogenes and Serratia marscences while the fungi isolates included Aspergillus flavus, Penicillium sp., Fusarium sp., Candida albicans and Alternaria sp. Staphylococcus aureus was the predominantly isolated bacterium while Penicillium sp. was the most isolated fungus. Though most of the microbial isolates were potential and or opportunistic pathogens, there was no correlation between the isolates in this study and the surveillance report of nosocomial infection during the period of study, hence the contribution of the indoor air cannot be established. From the reduction noticed in the morning samples, stringent measures such as proper disinfection and regular cleaning, restriction of patient relatives' movement in and out of the wards/units need to be enforced so as to improve the quality of indoor air of our hospital wards/units.

  17. Experiences of radiological examinations of buildings in Hungary.

    PubMed

    Homoki, Zsolt; Rell, Péter; Déri, Zsolt; Kocsy, Gábor

    2017-05-01

    Natural radioisotopes occur everywhere in the environment, being a source of exposure to the general population. Everyone is continuously exposed to terrestrial and cosmic radiations both indoors and outdoors, which are the main contributors to external exposure of individuals. There were made many ambient dose rate and indoor gamma radiation and radon concentration measurements in Hungarian by different laboratories. The main goal of the present work is the summarisation and evaluation of the latest results of the Laboratory of National Public Health Center National Research Directorate for Radiobiology and Radiohygiene. The reviewed examinations were made between 1995 and 2016. The average ambient dose rate was 103 ± 17 nSv/h and the average indoor gamma dose rate was 155 ± 47 nSv/h based on the data of 382 and 581 sampling points, respectively. The average indoor radon concentration was 108 Bq/m 3 with the median value of 75 Bq/m 3 based on the data of 415 sampling points. We performed an additional analysis of the results of 233 personal surveyed buildings where sophisticated gamma radiation and/or indoor radon concentration measurements were made. We were also interested in has got any affect the presence of slag to the radiation levels of the buildings? We found that usually elevated radiation can be detected in houses which contain slag compared to buildings without slag. In addition we conclude that the recommended minimum duration of short-term radon measurement shall be at least three days even if it does by closed conditions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Temporal variation of indoor air quality in an enclosed swine confinement building.

    PubMed

    O'Shaughnessy, P T; Achutan, C; Karsten, A W

    2002-11-01

    Human health hazards can exist in swine confinement buildings due to poor indoor air quality (IAQ). During this study, airborne dust and ammonia concentrations were monitored within a working farrowing facility as indicators of IAQ. The purposes of this study were to assess the temporal variability of the airborne dust and ammonia levels over both a daily and seasonal basis, and to determine the accuracy of real-time sensors relative to actively sampled data. An ammonia sensor, aerosol photometer, indoor relative humidity sensor, and datalogger containing an indoor temperature sensor were mounted on a board 180 cm above the floor in the center of a room in the facility. Sensor readings were taken once every 4 minutes during animal occupancy (3-week intervals). Measurements of total and respirable dust concentrations by standard method, aerosol size distribution, and ammonia concentrations were taken once per week, in addition to temperature and relative humidity measurements using a thermometer and sling psychrometer, respectively. Samples were taken between September 1999 and August 2000. Diurnal variations in airborne dust revealed an inverse relationship with changes in indoor temperature and, by association, changes in airflow rate. Ammonia levels changed despite relatively stable internal temperatures. This change may be related to both changes in flow rates and in volatility rates. As expected, contaminant concentrations increased during the cold weather months, but these differences were not significantly different from other seasons. However, total dust concentrations were very low (geometric mean = 0.8 mg/m3) throughout the year. Likewise, ammonia concentrations averaged only 3.6 ppm in the well-maintained study site.

  19. Individual and contextual characteristics of indoor and outdoor falls in older residents of São Paulo, Brazil.

    PubMed

    do Nascimento, Carla Ferreira; Duarte, Yeda Aparecida Oliveira; Lebrão, Maria Lúcia; Chiavegatto Filho, Alexandre Dias Porto

    To analyze a representative sample of older individuals of São Paulo, Brazil, according to outdoor fallers, indoor fallers and non-fallers, and to identify biological and socioeconomic (individual and contextual) factors associated with the occurrence and place of falls. A cross-sectional study was conducted using data (n = 1345) from the 2010 wave of the Health, Wellbeing and Aging (SABE) Study, a representative sample of older residents (60 years and older) of São Paulo, Brazil. Multinomial logistic analysis was performed to identify individual factors associated with the occurrence and place of falls, and multilevel multinomial analysis to identify contextual effects (green areas, violence, presence of slums and income inequality). 29% had a fall in the last 12 months, with 59% occurring in indoor spaces. Individuals who had outdoor falls were overall not statistically different from non-fallers; on the other hand, those who had the last fall indoor had worse health status. Moderate homicide rate was a factor associated with increased presence of indoor falls, compared with non-fallers. Our results describe the importance of falls, a common problem in active and community-dwelling older adults of São Paulo, Brazil. Transforming outdoor spaces into walk-friendly areas is essential to allow socialization and autonomy with safety. Creating strategies that take into account the most vulnerable populations, as those who live in violent areas and the oldest older adults, will be a growing challenge among developing countries. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Simultaneous sampling of indoor and outdoor airborne radioactivity after the Fukushima Daiichi nuclear power plant accident.

    PubMed

    Ishikawa, Tetsuo; Sorimachi, Atsuyuki; Arae, Hideki; Sahoo, Sarata Kumar; Janik, Miroslaw; Hosoda, Masahiro; Tokonami, Shinji

    2014-02-18

    Several studies have estimated inhalation doses for the public because of the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident. Most of them were based on measurement of radioactivity in outdoor air and included the assumption that people stayed outdoors all day. Although this assumption gives a conservative estimate, it is not realistic. The "air decontamination factor" (ratio of indoor to outdoor air radionuclide concentrations) was estimated from simultaneous sampling of radioactivity in both inside and outside air of one building. The building was a workplace and located at the National Institute of Radiological Sciences (NIRS) in Chiba Prefecture, Japan. Aerosol-associated radioactive materials in air were collected onto filters, and the filters were analyzed by γ spectrometry at NIRS. The filter sampling was started on March 15, 2011 and was continued for more than 1 year. Several radionuclides, such as (131)I, (134)Cs, and (137)Cs were found by measuring the filters with a germanium detector. The air decontamination factor was around 0.64 for particulate (131)I and 0.58 for (137)Cs. These values could give implications for the ratio of indoor to outdoor radionuclide concentrations after the FDNPP accident for a similar type of building.