The preclinical pharmacological profile of WAY-132983, a potent M1 preferring agonist.
Bartolomeo, A C; Morris, H; Buccafusco, J J; Kille, N; Rosenzweig-Lipson, S; Husbands, M G; Sabb, A L; Abou-Gharbia, M; Moyer, J A; Boast, C A
2000-02-01
Muscarinic M1 preferring agonists may improve cognitive deficits associated with Alzheimer's disease. Side effect assessment of the M1 preferring agonist WAY-132983 showed significant salivation (10 mg/kg i.p. or p.o.) and produced dose-dependent hypothermia after i. p. or p.o. administration. WAY-132983 significantly reduced scopolamine (0.3 mg/kg i.p.)-induced hyperswimming in mice. Cognitive assessment in rats used pretrained animals in a forced choice, 1-h delayed nonmatch-to-sample radial arm maze task. WAY-132983 (0.3 mg/kg i.p) significantly reduced scopolamine (0.3 mg/kg s.c.)-induced errors. Oral WAY-132983 attenuated scopolamine-induced errors; that is, errors produced after combining scopolamine and WAY-132983 (to 3 mg/kg p.o.) were not significantly increased compared with those of vehicle-treated control animals, whereas errors after scopolamine were significantly higher than those of control animals. With the use of miniosmotic pumps, 0.03 mg/kg/day (s.c.) WAY-132983 significantly reduced AF64A (3 nmol/3 microliter/lateral ventricle)-induced errors. Verification of AF64A cholinotoxicity showed significantly lower choline acetyltransferase activity in the hippocampi of AF64A-treated animals, with no significant changes in the striatal or frontal cortex. Cognitive assessment in primates involved the use of pretrained aged animals in a visual delayed match-to-sample procedure. Oral WAY-132983 significantly increased the number of correct responses during short and long delay interval testing. These effects were also apparent 24 h after administration. WAY-132983 exhibited cognitive benefit at doses lower than those producing undesirable effects; therefore, WAY-132983 is a potential candidate for improving the cognitive status of patients with Alzheimer's disease.
[Relations between health information systems and patient safety].
Nøhr, Christian
2012-11-05
Health information systems have the potential to reduce medical errors, and indeed many studies have shown a significant reduction. However, if the systems are not designed and implemented properly, there is evidence that suggest that new types of errors will arise--i.e., technology-induced errors. Health information systems will need to undergo a more rigorous evaluation. Usability evaluation and simulation test with humans in the loop can help to detect and prevent technology-induced errors before they are deployed in real health-care settings.
DiGirolamo, Gregory J; Smelson, David; Guevremont, Nathan
2015-08-01
Cue-induced craving is a clinically important aspect of cocaine addiction influencing ongoing use and sobriety. However, little is known about the relationship between cue-induced craving and cognitive control toward cocaine cues. While studies suggest that cocaine users have an attentional bias toward cocaine cues, the present study extends this research by testing if cocaine use disorder patients (CDPs) can control their eye movements toward cocaine cues and whether their response varied by cue-induced craving intensity. Thirty CDPs underwent a cue exposure procedure to dichotomize them into high and low craving groups followed by a modified antisaccade task in which subjects were asked to control their eye movements toward either a cocaine or neutral drug cue by looking away from the suddenly presented cue. The relationship between breakdowns in cognitive control (as measured by eye errors) and cue-induced craving (changes in self-reported craving following cocaine cue exposure) was investigated. CDPs overall made significantly more errors toward cocaine cues compared to neutral cues, with higher cravers making significantly more errors than lower cravers even though they did not differ significantly in addiction severity, impulsivity, anxiety, or depression levels. Cue-induced craving was the only specific and significant predictor of subsequent errors toward cocaine cues. Cue-induced craving directly and specifically relates to breakdowns of cognitive control toward cocaine cues in CDPs, with higher cravers being more susceptible. Hence, it may be useful identifying high cravers and target treatment toward curbing craving to decrease the likelihood of a subsequent breakdown in control. Copyright © 2015 Elsevier Ltd. All rights reserved.
Proton upsets in LSI memories in space
NASA Technical Reports Server (NTRS)
Mcnulty, P. J.; Wyatt, R. C.; Filz, R. C.; Rothwell, P. L.; Farrell, G. E.
1980-01-01
Two types of large scale integrated dynamic random access memory devices were tested and found to be subject to soft errors when exposed to protons incident at energies between 18 and 130 MeV. These errors are shown to differ significantly from those induced in the same devices by alphas from an Am-241 source. There is considerable variation among devices in their sensitivity to proton-induced soft errors, even among devices of the same type. For protons incident at 130 MeV, the soft error cross sections measured in these experiments varied from 10 to the -8th to 10 to the -6th sq cm/proton. For individual devices, however, the soft error cross section consistently increased with beam energy from 18-130 MeV. Analysis indicates that the soft errors induced by energetic protons result from spallation interactions between the incident protons and the nuclei of the atoms comprising the device. Because energetic protons are the most numerous of both the galactic and solar cosmic rays and form the inner radiation belt, proton-induced soft errors have potentially serious implications for many electronic systems flown in space.
Brain signaling and behavioral responses induced by exposure to (56)Fe-particle radiation
NASA Technical Reports Server (NTRS)
Denisova, N. A.; Shukitt-Hale, B.; Rabin, B. M.; Joseph, J. A.
2002-01-01
Previous experiments have demonstrated that exposure to 56Fe-particle irradiation (1.5 Gy, 1 GeV) produced aging-like accelerations in neuronal and behavioral deficits. Astronauts on long-term space flights will be exposed to similar heavy-particle radiations that might have similar deleterious effects on neuronal signaling and cognitive behavior. Therefore, the present study evaluated whether radiation-induced spatial learning and memory behavioral deficits are associated with region-specific brain signaling deficits by measuring signaling molecules previously found to be essential for behavior [pre-synaptic vesicle proteins, synaptobrevin and synaptophysin, and protein kinases, calcium-dependent PRKCs (also known as PKCs) and PRKA (PRKA RIIbeta)]. The results demonstrated a significant radiation-induced increase in reference memory errors. The increases in reference memory errors were significantly negatively correlated with striatal synaptobrevin and frontal cortical synaptophysin expression. Both synaptophysin and synaptobrevin are synaptic vesicle proteins that are important in cognition. Striatal PRKA, a memory signaling molecule, was also significantly negatively correlated with reference memory errors. Overall, our findings suggest that radiation-induced pre-synaptic facilitation may contribute to some previously reported radiation-induced decrease in striatal dopamine release and for the disruption of the central dopaminergic system integrity and dopamine-mediated behavior.
Brain signaling and behavioral responses induced by exposure to (56)Fe-particle radiation.
Denisova, N A; Shukitt-Hale, B; Rabin, B M; Joseph, J A
2002-12-01
Previous experiments have demonstrated that exposure to 56Fe-particle irradiation (1.5 Gy, 1 GeV) produced aging-like accelerations in neuronal and behavioral deficits. Astronauts on long-term space flights will be exposed to similar heavy-particle radiations that might have similar deleterious effects on neuronal signaling and cognitive behavior. Therefore, the present study evaluated whether radiation-induced spatial learning and memory behavioral deficits are associated with region-specific brain signaling deficits by measuring signaling molecules previously found to be essential for behavior [pre-synaptic vesicle proteins, synaptobrevin and synaptophysin, and protein kinases, calcium-dependent PRKCs (also known as PKCs) and PRKA (PRKA RIIbeta)]. The results demonstrated a significant radiation-induced increase in reference memory errors. The increases in reference memory errors were significantly negatively correlated with striatal synaptobrevin and frontal cortical synaptophysin expression. Both synaptophysin and synaptobrevin are synaptic vesicle proteins that are important in cognition. Striatal PRKA, a memory signaling molecule, was also significantly negatively correlated with reference memory errors. Overall, our findings suggest that radiation-induced pre-synaptic facilitation may contribute to some previously reported radiation-induced decrease in striatal dopamine release and for the disruption of the central dopaminergic system integrity and dopamine-mediated behavior.
NASA Astrophysics Data System (ADS)
Watanabe, Y.; Abe, S.
2014-06-01
Terrestrial neutron-induced soft errors in MOSFETs from a 65 nm down to a 25 nm design rule are analyzed by means of multi-scale Monte Carlo simulation using the PHITS-HyENEXSS code system. Nuclear reaction models implemented in PHITS code are validated by comparisons with experimental data. From the analysis of calculated soft error rates, it is clarified that secondary He and H ions provide a major impact on soft errors with decreasing critical charge. It is also found that the high energy component from 10 MeV up to several hundreds of MeV in secondary cosmic-ray neutrons has the most significant source of soft errors regardless of design rule.
Motion-induced phase error estimation and correction in 3D diffusion tensor imaging.
Van, Anh T; Hernando, Diego; Sutton, Bradley P
2011-11-01
A multishot data acquisition strategy is one way to mitigate B0 distortion and T2∗ blurring for high-resolution diffusion-weighted magnetic resonance imaging experiments. However, different object motions that take place during different shots cause phase inconsistencies in the data, leading to significant image artifacts. This work proposes a maximum likelihood estimation and k-space correction of motion-induced phase errors in 3D multishot diffusion tensor imaging. The proposed error estimation is robust, unbiased, and approaches the Cramer-Rao lower bound. For rigid body motion, the proposed correction effectively removes motion-induced phase errors regardless of the k-space trajectory used and gives comparable performance to the more computationally expensive 3D iterative nonlinear phase error correction method. The method has been extended to handle multichannel data collected using phased-array coils. Simulation and in vivo data are shown to demonstrate the performance of the method.
Stannard, David L.; Rosenberry, Donald O.; Winter, Thomas C.; Parkhurst, Renee S.
2004-01-01
Micrometeorological measurements of evapotranspiration (ET) often are affected to some degree by errors arising from limited fetch. A recently developed model was used to estimate fetch-induced errors in Bowen-ratio energy-budget measurements of ET made at a small wetland with fetch-to-height ratios ranging from 34 to 49. Estimated errors were small, averaging −1.90%±0.59%. The small errors are attributed primarily to the near-zero lower sensor height, and the negative bias reflects the greater Bowen ratios of the drier surrounding upland. Some of the variables and parameters affecting the error were not measured, but instead are estimated. A sensitivity analysis indicates that the uncertainty arising from these estimates is small. In general, fetch-induced error in measured wetland ET increases with decreasing fetch-to-height ratio, with increasing aridity and with increasing atmospheric stability over the wetland. Occurrence of standing water at a site is likely to increase the appropriate time step of data integration, for a given level of accuracy. Occurrence of extensive open water can increase accuracy or decrease the required fetch by allowing the lower sensor to be placed at the water surface. If fetch is highly variable and fetch-induced errors are significant, the variables affecting fetch (e.g., wind direction, water level) need to be measured. Fetch-induced error during the non-growing season may be greater or smaller than during the growing season, depending on how seasonal changes affect both the wetland and upland at a site.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watanabe, Y., E-mail: watanabe@aees.kyushu-u.ac.jp; Abe, S.
Terrestrial neutron-induced soft errors in MOSFETs from a 65 nm down to a 25 nm design rule are analyzed by means of multi-scale Monte Carlo simulation using the PHITS-HyENEXSS code system. Nuclear reaction models implemented in PHITS code are validated by comparisons with experimental data. From the analysis of calculated soft error rates, it is clarified that secondary He and H ions provide a major impact on soft errors with decreasing critical charge. It is also found that the high energy component from 10 MeV up to several hundreds of MeV in secondary cosmic-ray neutrons has the most significant sourcemore » of soft errors regardless of design rule.« less
Errors induced by catalytic effects in premixed flame temperature measurements
NASA Astrophysics Data System (ADS)
Pita, G. P. A.; Nina, M. N. R.
The evaluation of instantaneous temperature in a premixed flame using fine-wire Pt/Pt-(13 pct)Rh thermocouples was found to be subject to significant errors due to catalytic effects. An experimental study was undertaken to assess the influence of local fuel/air ratio, thermocouple wire diameter, and gas velocity on the thermocouple reading errors induced by the catalytic surface reactions. Measurements made with both coated and uncoated thermocouples showed that the catalytic effect imposes severe limitations on the accuracy of mean and fluctuating gas temperature in the radical-rich flame zone.
Moran, Lauren V; Stoeckel, Luke E; Wang, Kristina; Caine, Carolyn E; Villafuerte, Rosemond; Calderon, Vanessa; Baker, Justin T; Ongur, Dost; Janes, Amy C; Evins, A Eden; Pizzagalli, Diego A
2018-03-01
Nicotine improves attention and processing speed in individuals with schizophrenia. Few studies have investigated the effects of nicotine on cognitive control. Prior functional magnetic resonance imaging (fMRI) research demonstrates blunted activation of dorsal anterior cingulate cortex (dACC) and rostral anterior cingulate cortex (rACC) in response to error and decreased post-error slowing in schizophrenia. Participants with schizophrenia (n = 13) and healthy controls (n = 12) participated in a randomized, placebo-controlled, crossover study of the effects of transdermal nicotine on cognitive control. For each drug condition, participants underwent fMRI while performing the stop signal task where participants attempt to inhibit prepotent responses to "go (motor activation)" signals when an occasional "stop (motor inhibition)" signal appears. Error processing was evaluated by comparing "stop error" trials (failed response inhibition) to "go" trials. Resting-state fMRI data were collected prior to the task. Participants with schizophrenia had increased nicotine-induced activation of right caudate in response to errors compared to controls (DRUG × GROUP effect: p corrected < 0.05). Both groups had significant nicotine-induced activation of dACC and rACC in response to errors. Using right caudate activation to errors as a seed for resting-state functional connectivity analysis, relative to controls, participants with schizophrenia had significantly decreased connectivity between the right caudate and dACC/bilateral dorsolateral prefrontal cortices. In sum, we replicated prior findings of decreased post-error slowing in schizophrenia and found that nicotine was associated with more adaptive (i.e., increased) post-error reaction time (RT). This proof-of-concept pilot study suggests a role for nicotinic agents in targeting cognitive control deficits in schizophrenia.
Error Analysis and Validation for Insar Height Measurement Induced by Slant Range
NASA Astrophysics Data System (ADS)
Zhang, X.; Li, T.; Fan, W.; Geng, X.
2018-04-01
InSAR technique is an important method for large area DEM extraction. Several factors have significant influence on the accuracy of height measurement. In this research, the effect of slant range measurement for InSAR height measurement was analysis and discussed. Based on the theory of InSAR height measurement, the error propagation model was derived assuming no coupling among different factors, which directly characterise the relationship between slant range error and height measurement error. Then the theoretical-based analysis in combination with TanDEM-X parameters was implemented to quantitatively evaluate the influence of slant range error to height measurement. In addition, the simulation validation of InSAR error model induced by slant range was performed on the basis of SRTM DEM and TanDEM-X parameters. The spatial distribution characteristics and error propagation rule of InSAR height measurement were further discussed and evaluated.
Five-year lidar observational results and effects of El Chichon particles on Umkehr ozone data
NASA Astrophysics Data System (ADS)
Uchino, Osamu; Tabata, Isao; Kai, Kenji; Akita, Iwao
1988-08-01
Based on the values of integrated backscattering coefficient B, obtained from the ruby lidar measurements at the Meteorological Research Institude (MRI, at Tsukuba, Japan), the effect of dust particles due to two volcanic eruptions of Mt. El Chichon in 1982 on the Umkehr ozone data at the Tateno Aerological Observatory was determined. In addition, the effects of the aerosols on the Umkehr ozone data at Arosa, Switzerland were investigated using lidar data collected at Garmisch-Partenkirchen, Germany. It was found that both stratospheric and tropospheric aerosols induced a significant negative ozone error in the uppermost layers (33-47 km), caused a small and usually negative ozone error in layers between 16 and 33 km, and induced a significant positive ozone error in layers between 6 and 16 km.
2013-01-01
Objectives Health information technology (HIT) research findings suggested that new healthcare technologies could reduce some types of medical errors while at the same time introducing classes of medical errors (i.e., technology-induced errors). Technology-induced errors have their origins in HIT, and/or HIT contribute to their occurrence. The objective of this paper is to review current trends in the published literature on HIT safety. Methods A review and synthesis of the medical and life sciences literature focusing on the area of technology-induced error was conducted. Results There were four main trends in the literature on technology-induced error. The following areas were addressed in the literature: definitions of technology-induced errors; models, frameworks and evidence for understanding how technology-induced errors occur; a discussion of monitoring; and methods for preventing and learning about technology-induced errors. Conclusions The literature focusing on technology-induced errors continues to grow. Research has focused on the defining what an error is, models and frameworks used to understand these new types of errors, monitoring of such errors and methods that can be used to prevent these errors. More research will be needed to better understand and mitigate these types of errors. PMID:23882411
Salient Distractors Can Induce Saccade Adaptation
Khan, Afsheen; McFadden, Sally A.; Wallman, Josh
2014-01-01
When saccadic eye movements consistently fail to land on their intended target, saccade accuracy is maintained by gradually adapting the movement size of successive saccades. The proposed error signal for saccade adaptation has been based on the distance between where the eye lands and the visual target (retinal error). We studied whether the error signal could alternatively be based on the distance between the predicted and actual locus of attention after the saccade. Unlike conventional adaptation experiments that surreptitiously displace the target once a saccade is initiated towards it, we instead attempted to draw attention away from the target by briefly presenting salient distractor images on one side of the target after the saccade. To test whether less salient, more predictable distractors would induce less adaptation, we separately used fixed random noise distractors. We found that both visual attention distractors were able to induce a small degree of downward saccade adaptation but significantly more to the more salient distractors. As in conventional adaptation experiments, upward adaptation was less effective and salient distractors did not significantly increase amplitudes. We conclude that the locus of attention after the saccade can act as an error signal for saccade adaptation. PMID:24876947
Network Adjustment of Orbit Errors in SAR Interferometry
NASA Astrophysics Data System (ADS)
Bahr, Hermann; Hanssen, Ramon
2010-03-01
Orbit errors can induce significant long wavelength error signals in synthetic aperture radar (SAR) interferograms and thus bias estimates of wide-scale deformation phenomena. The presented approach aims for correcting orbit errors in a preprocessing step to deformation analysis by modifying state vectors. Whereas absolute errors in the orbital trajectory are negligible, the influence of relative errors (baseline errors) is parametrised by their parallel and perpendicular component as a linear function of time. As the sensitivity of the interferometric phase is only significant with respect to the perpendicular base-line and the rate of change of the parallel baseline, the algorithm focuses on estimating updates to these two parameters. This is achieved by a least squares approach, where the unwrapped residual interferometric phase is observed and atmospheric contributions are considered to be stochastic with constant mean. To enhance reliability, baseline errors are adjusted in an overdetermined network of interferograms, yielding individual orbit corrections per acquisition.
Awareness of technology-induced errors and processes for identifying and preventing such errors.
Bellwood, Paule; Borycki, Elizabeth M; Kushniruk, Andre W
2015-01-01
There is a need to determine if organizations working with health information technology are aware of technology-induced errors and how they are addressing and preventing them. The purpose of this study was to: a) determine the degree of technology-induced error awareness in various Canadian healthcare organizations, and b) identify those processes and procedures that are currently in place to help address, manage, and prevent technology-induced errors. We identified a lack of technology-induced error awareness among participants. Participants identified there was a lack of well-defined procedures in place for reporting technology-induced errors, addressing them when they arise, and preventing them.
Borycki, Elizabeth; Kushniruk, Andre; Carvalho, Christopher
2013-01-01
Internationally, health information systems (HIS) safety has emerged as a significant concern for governments. Recently, research has emerged that has documented the ability of HIS to be implicated in the harm and death of patients. Researchers have attempted to develop methods that can be used to prevent or reduce technology-induced errors. Some researchers are developing methods that can be employed prior to systems release. These methods include the development of safety heuristics and clinical simulations. In this paper, we outline our methodology for developing safety heuristics specific to identifying the features or functions of a HIS user interface design that may lead to technology-induced errors. We follow this with a description of a methodological approach to validate these heuristics using clinical simulations. PMID:23606902
Dynamically corrected gates for singlet-triplet spin qubits with control-dependent errors
NASA Astrophysics Data System (ADS)
Jacobson, N. Tobias; Witzel, Wayne M.; Nielsen, Erik; Carroll, Malcolm S.
2013-03-01
Magnetic field inhomogeneity due to random polarization of quasi-static local magnetic impurities is a major source of environmentally induced error for singlet-triplet double quantum dot (DQD) spin qubits. Moreover, for singlet-triplet qubits this error may depend on the applied controls. This effect is significant when a static magnetic field gradient is applied to enable full qubit control. Through a configuration interaction analysis, we observe that the dependence of the field inhomogeneity-induced error on the DQD bias voltage can vary systematically as a function of the controls for certain experimentally relevant operating regimes. To account for this effect, we have developed a straightforward prescription for adapting dynamically corrected gate sequences that assume control-independent errors into sequences that compensate for systematic control-dependent errors. We show that accounting for such errors may lead to a substantial increase in gate fidelities. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. DOE's National Nuclear Security Administration under contract DE-AC04-94AL85000.
Zhang, Jiamei; Wang, Yan; Chen, Xiaoqin
2016-04-01
To evaluate and compare refractive outcomes of moderate- and high-astigmatism correction after wavefront-guided laser in situ keratomileusis (LASIK) and small-incision lenticule extraction (SMILE). This comparative study enrolled a total of 64 eyes that had undergone SMILE (42 eyes) and wavefront-guided LASIK (22 eyes). Preoperative cylindrical diopters were ≤-2.25 D in moderate- and >-2.25 D in high-astigmatism subgroups. The refractive results were analyzed based on the Alpins vector method that included target-induced astigmatism, surgically induced astigmatism, difference vector, correction index, index of success, magnitude of error, angle of error, and flattening index. All subjects completed the 3-month follow-up. No significant differences were found in the target-induced astigmatism, surgically induced astigmatism, and difference vector between SMILE and wavefront-guided LASIK. However, the average angle of error value was -1.00 ± 3.16 after wavefront-guided LASIK and 1.22 ± 3.85 after SMILE with statistical significance (P < 0.05). The absolute angle of error value was statistically correlated with difference vector and index of success after both procedures. In the moderate-astigmatism group, correction index was 1.04 ± 0.15 after wavefront-guided LASIK and 0.88 ± 0.15 after SMILE (P < 0.05). However, in the high-astigmatism group, correction index was 0.87 ± 0.13 after wavefront-guided LASIK and 0.88 ± 0.12 after SMILE (P = 0.889). Both procedures showed preferable outcomes in the correction of moderate and high astigmatism. However, high astigmatism was undercorrected after both procedures. Axial error of astigmatic correction may be one of the potential factors for the undercorrection.
Patterned wafer geometry grouping for improved overlay control
NASA Astrophysics Data System (ADS)
Lee, Honggoo; Han, Sangjun; Woo, Jaeson; Park, Junbeom; Song, Changrock; Anis, Fatima; Vukkadala, Pradeep; Jeon, Sanghuck; Choi, DongSub; Huang, Kevin; Heo, Hoyoung; Smith, Mark D.; Robinson, John C.
2017-03-01
Process-induced overlay errors from outside the litho cell have become a significant contributor to the overlay error budget including non-uniform wafer stress. Previous studies have shown the correlation between process-induced stress and overlay and the opportunity for improvement in process control, including the use of patterned wafer geometry (PWG) metrology to reduce stress-induced overlay signatures. Key challenges of volume semiconductor manufacturing are how to improve not only the magnitude of these signatures, but also the wafer to wafer variability. This work involves a novel technique of using PWG metrology to provide improved litho-control by wafer-level grouping based on incoming process induced overlay, relevant for both 3D NAND and DRAM. Examples shown in this study are from 19 nm DRAM manufacturing.
MacDonald, M. Ethan; Forkert, Nils D.; Pike, G. Bruce; Frayne, Richard
2016-01-01
Purpose Volume flow rate (VFR) measurements based on phase contrast (PC)-magnetic resonance (MR) imaging datasets have spatially varying bias due to eddy current induced phase errors. The purpose of this study was to assess the impact of phase errors in time averaged PC-MR imaging of the cerebral vasculature and explore the effects of three common correction schemes (local bias correction (LBC), local polynomial correction (LPC), and whole brain polynomial correction (WBPC)). Methods Measurements of the eddy current induced phase error from a static phantom were first obtained. In thirty healthy human subjects, the methods were then assessed in background tissue to determine if local phase offsets could be removed. Finally, the techniques were used to correct VFR measurements in cerebral vessels and compared statistically. Results In the phantom, phase error was measured to be <2.1 ml/s per pixel and the bias was reduced with the correction schemes. In background tissue, the bias was significantly reduced, by 65.6% (LBC), 58.4% (LPC) and 47.7% (WBPC) (p < 0.001 across all schemes). Correction did not lead to significantly different VFR measurements in the vessels (p = 0.997). In the vessel measurements, the three correction schemes led to flow measurement differences of -0.04 ± 0.05 ml/s, 0.09 ± 0.16 ml/s, and -0.02 ± 0.06 ml/s. Although there was an improvement in background measurements with correction, there was no statistical difference between the three correction schemes (p = 0.242 in background and p = 0.738 in vessels). Conclusions While eddy current induced phase errors can vary between hardware and sequence configurations, our results showed that the impact is small in a typical brain PC-MR protocol and does not have a significant effect on VFR measurements in cerebral vessels. PMID:26910600
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, T; Kumaraswamy, L
Purpose: Detection of treatment delivery errors is important in radiation therapy. However, accurate quantification of delivery errors is also of great importance. This study aims to evaluate the 3DVH software’s ability to accurately quantify delivery errors. Methods: Three VMAT plans (prostate, H&N and brain) were randomly chosen for this study. First, we evaluated whether delivery errors could be detected by gamma evaluation. Conventional per-beam IMRT QA was performed with the ArcCHECK diode detector for the original plans and for the following modified plans: (1) induced dose difference error up to ±4.0% and (2) control point (CP) deletion (3 to 10more » CPs were deleted) (3) gantry angle shift error (3 degree uniformly shift). 2D and 3D gamma evaluation were performed for all plans through SNC Patient and 3DVH, respectively. Subsequently, we investigated the accuracy of 3DVH analysis for all cases. This part evaluated, using the Eclipse TPS plans as standard, whether 3DVH accurately can model the changes in clinically relevant metrics caused by the delivery errors. Results: 2D evaluation seemed to be more sensitive to delivery errors. The average differences between ECLIPSE predicted and 3DVH results for each pair of specific DVH constraints were within 2% for all three types of error-induced treatment plans, illustrating the fact that 3DVH is fairly accurate in quantifying the delivery errors. Another interesting observation was that even though the gamma pass rates for the error plans are high, the DVHs showed significant differences between original plan and error-induced plans in both Eclipse and 3DVH analysis. Conclusion: The 3DVH software is shown to accurately quantify the error in delivered dose based on clinically relevant DVH metrics, where a conventional gamma based pre-treatment QA might not necessarily detect.« less
Research of laser echo signal simulator
NASA Astrophysics Data System (ADS)
Xu, Rui; Shi, Rui; Wang, Xin; Li, Zhou
2015-11-01
Laser echo signal simulator is one of the most significant components of hardware-in-the-loop (HWIL) simulation systems for LADAR. System model and time series model of laser echo signal simulator are established. Some influential factors which could induce fixed error and random error on the simulated return signals are analyzed, and then these system insertion errors are analyzed quantitatively. Using this theoretical model, the simulation system is investigated experimentally. The results corrected by subtracting fixed error indicate that the range error of the simulated laser return signal is less than 0.25m, and the distance range that the system can simulate is from 50m to 20km.
Effect of different head-neck-jaw postures on cervicocephalic kinesthetic sense.
Zafar, H; Alghadir, A H; Iqbal, Z A
2017-12-01
To investigate the effect of different induced head-neck-jaw postures on head-neck relocation error among healthy subjects. 30 healthy adult male subjects participated in this study. Cervicocephalic kinesthetic sense was measured while standing, habitual sitting, habitual sitting with clenched jaw and habitual sitting with forward head posture during right rotation, left rotation, flexion and extension using kinesthetic sensibility test. Head-neck relocation error was least while standing, followed by habitual sitting, habitual sitting with forward head posture and habitual sitting with jaw clenched. However, there was no significant difference in error between different tested postures during all the movements. To the best of our knowledge, this is the first study to see the effect of different induced head-neck-jaw postures on head-neck position sense among healthy subjects. Assuming a posture for a short duration of time doesn't affect head-neck relocation error in normal healthy subjects.
Hong, KyungPyo; Jeong, Eun-Kee; Wall, T. Scott; Drakos, Stavros G.; Kim, Daniel
2015-01-01
Purpose To develop and evaluate a wideband arrhythmia-insensitive-rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by implantable-cardioverter-defibrillator (ICD). Methods We developed a wideband AIR pulse sequence by incorporating a saturation pulse with wide frequency bandwidth (8.9 kHz), in order to achieve uniform T1 weighting in the heart with ICD. We tested the performance of original and “wideband” AIR cardiac T1 mapping pulse sequences in phantom and human experiments at 1.5T. Results In 5 phantoms representing native myocardium and blood and post-contrast blood/tissue T1 values, compared with the control T1 values measured with an inversion-recovery pulse sequence without ICD, T1 values measured with original AIR with ICD were considerably lower (absolute percent error >29%), whereas T1 values measured with wideband AIR with ICD were similar (absolute percent error <5%). Similarly, in 11 human subjects, compared with the control T1 values measured with original AIR without ICD, T1 measured with original AIR with ICD was significantly lower (absolute percent error >10.1%), whereas T1 measured with wideband AIR with ICD was similar (absolute percent error <2.0%). Conclusion This study demonstrates the feasibility of a wideband pulse sequence for cardiac T1 mapping without significant image artifacts induced by ICD. PMID:25975192
Gray, Rob; Orn, Anders; Woodman, Tim
2017-02-01
Are pressure-induced performance errors in experts associated with novice-like skill execution (as predicted by reinvestment/conscious processing theories) or expert execution toward a result that the performer typically intends to avoid (as predicted by ironic processes theory)? The present study directly compared these predictions using a baseball pitching task with two groups of experienced pitchers. One group was shown only their target, while the other group was shown the target and an ironic (avoid) zone. Both groups demonstrated significantly fewer target hits under pressure. For the target-only group, this was accompanied by significant changes in expertise-related kinematic variables. In the ironic group, the number of pitches thrown in the ironic zone was significantly higher under pressure, and there were no significant changes in kinematics. These results suggest that information about an opponent can influence the mechanisms underlying pressure-induced performance errors.
Ionospheric Impacts on UHF Space Surveillance
NASA Astrophysics Data System (ADS)
Jones, J. C.
2017-12-01
Earth's atmosphere contains regions of ionized plasma caused by the interaction of highly energetic solar radiation. This region of ionization is called the ionosphere and varies significantly with altitude, latitude, local solar time, season, and solar cycle. Significant ionization begins at about 100 km (E layer) with a peak in the ionization at about 300 km (F2 layer). Above the F2 layer, the atmosphere is mostly ionized but the ion and electron densities are low due to the unavailability of neutral molecules for ionization so the density decreases exponentially with height to well over 1000 km. The gradients of these variations in the ionosphere play a significant role in radio wave propagation. These gradients induce variations in the index of refraction and cause some radio waves to refract. The amount of refraction depends on the magnitude and direction of the electron density gradient and the frequency of the radio wave. The refraction is significant at HF frequencies (3-30 MHz) with decreasing effects toward the UHF (300-3000 MHz) range. UHF is commonly used for tracking of space objects in low Earth orbit (LEO). While ionospheric refraction is small for UHF frequencies, it can cause errors in range, azimuth angle, and elevation angle estimation by ground-based radars tracking space objects. These errors can cause significant errors in precise orbit determinations. For radio waves transiting the ionosphere, it is important to understand and account for these effects. Using a sophisticated radio wave propagation tool suite and an empirical ionospheric model, we calculate the errors induced by the ionosphere in a simulation of a notional space surveillance radar tracking objects in LEO. These errors are analyzed to determine daily, monthly, annual, and solar cycle trends. Corrections to surveillance radar measurements can be adapted from our simulation capability.
Measurement errors in voice-key naming latency for Hiragana.
Yamada, Jun; Tamaoka, Katsuo
2003-12-01
This study makes explicit the limitations and possibilities of voice-key naming latency research on single hiragana symbols (a Japanese syllabic script) by examining three sets of voice-key naming data against Sakuma, Fushimi, and Tatsumi's 1997 speech-analyzer voice-waveform data. Analysis showed that voice-key measurement errors can be substantial in standard procedures as they may conceal the true effects of significant variables involved in hiragana-naming behavior. While one can avoid voice-key measurement errors to some extent by applying Sakuma, et al.'s deltas and by excluding initial phonemes which induce measurement errors, such errors may be ignored when test items are words and other higher-level linguistic materials.
Realtime mitigation of GPS SA errors using Loran-C
NASA Technical Reports Server (NTRS)
Braasch, Soo Y.
1994-01-01
The hybrid use of Loran-C with the Global Positioning System (GPS) was shown capable of providing a sole-means of enroute air radionavigation. By allowing pilots to fly direct to their destinations, use of this system is resulting in significant time savings and therefore fuel savings as well. However, a major error source limiting the accuracy of GPS is the intentional degradation of the GPS signal known as Selective Availability (SA). SA-induced position errors are highly correlated and far exceed all other error sources (horizontal position error: 100 meters, 95 percent). Realtime mitigation of SA errors from the position solution is highly desirable. How that can be achieved is discussed. The stability of Loran-C signals is exploited to reduce SA errors. The theory behind this technique is discussed and results using bench and flight data are given.
Effect of different head-neck-jaw postures on cervicocephalic kinesthetic sense
Zafar, Hamayun; Alghadir, Ahmad H.; Iqbal, Zaheen A.
2017-01-01
Objectives: To investigate the effect of different induced head-neck-jaw postures on head-neck relocation error among healthy subjects. Methods: 30 healthy adult male subjects participated in this study. Cervicocephalic kinesthetic sense was measured while standing, habitual sitting, habitual sitting with clenched jaw and habitual sitting with forward head posture during right rotation, left rotation, flexion and extension using kinesthetic sensibility test. Results: Head-neck relocation error was least while standing, followed by habitual sitting, habitual sitting with forward head posture and habitual sitting with jaw clenched. However, there was no significant difference in error between different tested postures during all the movements. Conclusions: To the best of our knowledge, this is the first study to see the effect of different induced head-neck-jaw postures on head-neck position sense among healthy subjects. Assuming a posture for a short duration of time doesn’t affect head-neck relocation error in normal healthy subjects. PMID:29199196
Modal Correction Method For Dynamically Induced Errors In Wind-Tunnel Model Attitude Measurements
NASA Technical Reports Server (NTRS)
Buehrle, R. D.; Young, C. P., Jr.
1995-01-01
This paper describes a method for correcting the dynamically induced bias errors in wind tunnel model attitude measurements using measured modal properties of the model system. At NASA Langley Research Center, the predominant instrumentation used to measure model attitude is a servo-accelerometer device that senses the model attitude with respect to the local vertical. Under smooth wind tunnel operating conditions, this inertial device can measure the model attitude with an accuracy of 0.01 degree. During wind tunnel tests when the model is responding at high dynamic amplitudes, the inertial device also senses the centrifugal acceleration associated with model vibration. This centrifugal acceleration results in a bias error in the model attitude measurement. A study of the response of a cantilevered model system to a simulated dynamic environment shows significant bias error in the model attitude measurement can occur and is vibration mode and amplitude dependent. For each vibration mode contributing to the bias error, the error is estimated from the measured modal properties and tangential accelerations at the model attitude device. Linear superposition is used to combine the bias estimates for individual modes to determine the overall bias error as a function of time. The modal correction model predicts the bias error to a high degree of accuracy for the vibration modes characterized in the simulated dynamic environment.
NASA Astrophysics Data System (ADS)
Nunez, F.; Romero, A.; Clua, J.; Mas, J.; Tomas, A.; Catalan, A.; Castellsaguer, J.
2005-08-01
MARES (Muscle Atrophy Research and Exercise System) is a computerized ergometer for neuromuscular research to be flown and installed onboard the International Space Station in 2007. Validity of data acquired depends on controlling and reducing all significant error sources. One of them is the misalignment of the joint rotation axis with respect to the motor axis.The error induced on the measurements is proportional to the misalignment between both axis. Therefore, the restraint system's performance is critical [1]. MARES HRS (Human Restraint System) assures alignment within an acceptable range while performing the exercise (results: elbow movement:13.94mm+/-5.45, Knee movement: 22.36mm+/- 6.06 ) and reproducibility of human positioning (results: elbow movement: 2.82mm+/-1.56, Knee movement 7.45mm+/-4.8 ). These results allow limiting measurement errors induced by misalignment.
Methods for Addressing Technology-induced Errors: The Current State.
Borycki, E; Dexheimer, J W; Hullin Lucay Cossio, C; Gong, Y; Jensen, S; Kaipio, J; Kennebeck, S; Kirkendall, E; Kushniruk, A W; Kuziemsky, C; Marcilly, R; Röhrig, R; Saranto, K; Senathirajah, Y; Weber, J; Takeda, H
2016-11-10
The objectives of this paper are to review and discuss the methods that are being used internationally to report on, mitigate, and eliminate technology-induced errors. The IMIA Working Group for Health Informatics for Patient Safety worked together to review and synthesize some of the main methods and approaches associated with technology- induced error reporting, reduction, and mitigation. The work involved a review of the evidence-based literature as well as guideline publications specific to health informatics. The paper presents a rich overview of current approaches, issues, and methods associated with: (1) safe HIT design, (2) safe HIT implementation, (3) reporting on technology-induced errors, (4) technology-induced error analysis, and (5) health information technology (HIT) risk management. The work is based on research from around the world. Internationally, researchers have been developing methods that can be used to identify, report on, mitigate, and eliminate technology-induced errors. Although there remain issues and challenges associated with the methodologies, they have been shown to improve the quality and safety of HIT. Since the first publications documenting technology-induced errors in healthcare in 2005, we have seen in a short 10 years researchers develop ways of identifying and addressing these types of errors. We have also seen organizations begin to use these approaches. Knowledge has been translated into practice in a short ten years whereas the norm for other research areas is of 20 years.
Induced mood and selective attention.
Brand, N; Verspui, L; Oving, A
1997-04-01
Subjects (N = 60) were randomly assigned to an elated, depressed, or neutral mood-induction condition to assess the effect of mood state on cognitive functioning. In the elated condition film fragments expressing happiness and euphoria were shown. In the depressed condition some frightening and distressing film fragments were presented. The neutral group watched no film. Mood states were measured using the Profile of Mood States, and a Stroop task assessed selective attention. Both were presented by computer. The induction groups differed significantly in the expected direction on the mood subscales Anger, Tension, Depression, Vigour, and Fatigue, and also in the mean scale response times, i.e., slower responses for the depressed condition and faster for the elated one. Differences between conditions were found in the errors on the Stroop: in the depressed condition were the fewest errors and significantly longer error reaction times. Speed of error was associated with self-reported fatigue.
Chan, Tommy C Y; Cheng, George P M; Wang, Zheng; Tham, Clement C Y; Woo, Victor C P; Jhanji, Vishal
2015-08-01
To evaluate the outcomes of femtosecond-assisted arcuate keratotomy combined with cataract surgery in eyes with low to moderate corneal astigmatism. Retrospective, interventional case series. This study included patients who underwent combined femtosecond-assisted phacoemulsification and arcuate keratotomy between March 2013 and August 2013. Keratometric astigmatism was evaluated before and 2 months after the surgery. Vector analysis of the astigmatic changes was performed using the Alpins method. Overall, 54 eyes of 54 patients (18 male and 36 female; mean age, 68.8 ± 11.4 years) were included. The mean preoperative (target-induced astigmatism) and postoperative astigmatism was 1.33 ± 0.57 diopters (D) and 0.87 ± 0.56 D, respectively (P < .001). The magnitude of error (difference between surgically induced and target-induced astigmatism) (-0.13 ± 0.68 D), as well as the correction index (ratio of surgically induced and target-induced astigmatism) (0.86 ± 0.52), demonstrated slight undercorrection. The angle of error was very close to 0, indicating no significant systematic error of misaligned treatment. However, the absolute angle of error showed a less favorable range (17.5 ± 19.2 degrees), suggesting variable factors such as healing or alignment at an individual level. There were no intraoperative or postoperative complications. Combined phacoemulsification with arcuate keratotomy using femtosecond laser appears to be a relatively easy and safe means for management of low to moderate corneal astigmatism in cataract surgery candidates. Misalignment at an individual level can reduce its effectiveness. This issue remains to be elucidated in future studies. Copyright © 2015 Elsevier Inc. All rights reserved.
An Analysis of Ripple and Error Fields Induced by a Blanket in the CFETR
NASA Astrophysics Data System (ADS)
Yu, Guanying; Liu, Xufeng; Liu, Songlin
2016-10-01
The Chinese Fusion Engineering Tokamak Reactor (CFETR) is an important intermediate device between ITER and DEMO. The Water Cooled Ceramic Breeder (WCCB) blanket whose structural material is mainly made of Reduced Activation Ferritic/Martensitic (RAFM) steel, is one of the candidate conceptual blanket design. An analysis of ripple and error field induced by RAFM steel in WCCB is evaluated with the method of static magnetic analysis in the ANSYS code. Significant additional magnetic field is produced by blanket and it leads to an increased ripple field. Maximum ripple along the separatrix line reaches 0.53% which is higher than 0.5% of the acceptable design value. Simultaneously, one blanket module is taken out for heating purpose and the resulting error field is calculated to be seriously against the requirement. supported by National Natural Science Foundation of China (No. 11175207) and the National Magnetic Confinement Fusion Program of China (No. 2013GB108004)
Cleared for the visual approach: Human factor problems in air carrier operations
NASA Technical Reports Server (NTRS)
Monan, W. P.
1983-01-01
The study described herein, a set of 353 ASRS reports of unique aviation occurrences significantly involving visual approaches was examined to identify hazards and pitfalls embedded in the visual approach procedure and to consider operational practices that might help avoid future mishaps. Analysis of the report set identified nine aspects of the visual approach procedure that appeared to be predisposing conditions for inducing or exacerbating the effects of operational errors by flight crew members or controllers. Predisposing conditions, errors, and operational consequences of the errors are discussed. In a summary, operational policies that might mitigate the problems are examined.
Methods for Addressing Technology-Induced Errors: The Current State
Dexheimer, J. W.; Hullin Lucay Cossio, C.; Gong, Y.; Jensen, S.; Kaipio, J.; Kennebeck, S.; Kirkendall, E.; Kushniruk, A. W.; Kuziemsky, C.; Marcilly, R.; Röhrig, R.; Saranto, K.; Senathirajah, Y.; Weber, J.; Takeda, H.
2016-01-01
Summary Objectives The objectives of this paper are to review and discuss the methods that are being used internationally to report on, mitigate, and eliminate technology-induced errors. Methods The IMIA Working Group for Health Informatics for Patient Safety worked together to review and synthesize some of the main methods and approaches associated with technology-induced error reporting, reduction, and mitigation. The work involved a review of the evidence-based literature as well as guideline publications specific to health informatics. Results The paper presents a rich overview of current approaches, issues, and methods associated with: (1) safe HIT design, (2) safe HIT implementation, (3) reporting on technology-induced errors, (4) technology-induced error analysis, and (5) health information technology (HIT) risk management. The work is based on research from around the world. Conclusions Internationally, researchers have been developing methods that can be used to identify, report on, mitigate, and eliminate technology-induced errors. Although there remain issues and challenges associated with the methodologies, they have been shown to improve the quality and safety of HIT. Since the first publications documenting technology-induced errors in healthcare in 2005, we have seen in a short 10 years researchers develop ways of identifying and addressing these types of errors. We have also seen organizations begin to use these approaches. Knowledge has been translated into practice in a short ten years whereas the norm for other research areas is of 20 years. PMID:27830228
NASA Technical Reports Server (NTRS)
Miller, J. M.
1980-01-01
ATMOS is a Fourier transform spectrometer to measure atmospheric trace molecules over a spectral range of 2-16 microns. Assessment of the system performance of ATMOS includes evaluations of optical system errors induced by thermal and structural effects. In order to assess the optical system errors induced from thermal and structural effects, error budgets are assembled during system engineering tasks and line of sight and wavefront deformations predictions (using operational thermal and vibration environments and computer models) are subsequently compared to the error budgets. This paper discusses the thermal/structural error budgets, modelling and analysis methods used to predict thermal/structural induced errors and the comparisons that show that predictions are within the error budgets.
Reduction of Orifice-Induced Pressure Errors
NASA Technical Reports Server (NTRS)
Plentovich, Elizabeth B.; Gloss, Blair B.; Eves, John W.; Stack, John P.
1987-01-01
Use of porous-plug orifice reduces or eliminates errors, induced by orifice itself, in measuring static pressure on airfoil surface in wind-tunnel experiments. Piece of sintered metal press-fitted into static-pressure orifice so it matches surface contour of model. Porous material reduces orifice-induced pressure error associated with conventional orifice of same or smaller diameter. Also reduces or eliminates additional errors in pressure measurement caused by orifice imperfections. Provides more accurate measurements in regions with very thin boundary layers.
Kam, Winnie W Y; Lake, Vanessa; Banos, Connie; Davies, Justin; Banati, Richard
2013-05-30
Quantitative polymerase chain reaction (qPCR) has been widely used to quantify changes in gene copy numbers after radiation exposure. Here, we show that gamma irradiation ranging from 10 to 100 Gy of cells and cell-free DNA samples significantly affects the measured qPCR yield, due to radiation-induced fragmentation of the DNA template and, therefore, introduces errors into the estimation of gene copy numbers. The radiation-induced DNA fragmentation and, thus, measured qPCR yield varies with temperature not only in living cells, but also in isolated DNA irradiated under cell-free conditions. In summary, the variability in measured qPCR yield from irradiated samples introduces a significant error into the estimation of both mitochondrial and nuclear gene copy numbers and may give spurious evidence for polyploidization.
Nimodipine alters acquisition of a visual discrimination task in chicks.
Deyo, R; Panksepp, J; Conner, R L
1990-03-01
Chicks 5 days old received intraperitoneal injections of nimodipine 30 min before training on either a visual discrimination task (0, 0.5, 1.0, or 5.0 mg/kg) or a test of separation-induced distress vocalizations (0, 0.5, or 2.5 mg/kg). Chicks receiving 1.0 mg/kg nimodipine made significantly fewer visual discrimination errors than vehicle controls by trials 41-60, but did not differ from controls 24 h later. Chicks in the 5 mg/kg group made significantly more errors when compared to controls both during acquisition of the task and during retention. Nimodipine did not alter separation-induced distress vocalizations at any of the doses tested, suggesting that nimodipine's effects on learning cannot be attributed to a reduction in separation distress. These data indicate that nimodipine's facilitation of learning in young subjects is dose dependent, but nimodipine failed to enhance retention.
SEU induced errors observed in microprocessor systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asenek, V.; Underwood, C.; Oldfield, M.
In this paper, the authors present software tools for predicting the rate and nature of observable SEU induced errors in microprocessor systems. These tools are built around a commercial microprocessor simulator and are used to analyze real satellite application systems. Results obtained from simulating the nature of SEU induced errors are shown to correlate with ground-based radiation test data.
Prediction error induced motor contagions in human behaviors.
Ikegami, Tsuyoshi; Ganesh, Gowrishankar; Takeuchi, Tatsuya; Nakamoto, Hiroki
2018-05-29
Motor contagions refer to implicit effects on one's actions induced by observed actions. Motor contagions are believed to be induced simply by action observation and cause an observer's action to become similar to the action observed. In contrast, here we report a new motor contagion that is induced only when the observation is accompanied by prediction errors - differences between actions one observes and those he/she predicts or expects. In two experiments, one on whole-body baseball pitching and another on simple arm reaching, we show that the observation of the same action induces distinct motor contagions, depending on whether prediction errors are present or not. In the absence of prediction errors, as in previous reports, participants' actions changed to become similar to the observed action, while in the presence of prediction errors, their actions changed to diverge away from it, suggesting distinct effects of action observation and action prediction on human actions. © 2018, Ikegami et al.
Ribot-Ciscar, Edith; Aimonetti, Jean-Marc; Azulay, Jean-Philippe
2017-12-15
The present study investigates whether proprioceptive training, based on kinesthetic illusions, can help in re-educating the processing of muscle proprioceptive input, which is impaired in patients with Parkinson's disease (PD). The processing of proprioceptive input before and after training was evaluated by determining the error in the amplitude of voluntary dorsiflexion ankle movement (20°), induced by applying a vibration on the tendon of the gastrocnemius-soleus muscle (a vibration-induced movement error). The training consisted of the subjects focusing their attention upon a series of illusory movements of the ankle. Eleven PD patients and eleven age-matched control subjects were tested. Before training, vibration reduced dorsiflexion amplitude in controls by 4.3° (P<0.001); conversely, vibration was inefficient in PD's movement amplitude (reduction of 2.1°, P=0.20). After training, vibration significantly reduced the estimated movement amplitude in PD patients by 5.3° (P=0.01). This re-emergence of a vibration-induced error leads us to conclude that proprioceptive training, based on kinesthetic illusions, is a simple means for re-educating the processing of muscle proprioceptive input in PD patients. Such complementary training should be included in rehabilitation programs that presently focus on improving balance and motor performance. Copyright © 2017 Elsevier B.V. All rights reserved.
Multipath induced errors in meteorological Doppler/interferometer location systems
NASA Technical Reports Server (NTRS)
Wallace, R. G.
1984-01-01
One application of an RF interferometer aboard a low-orbiting spacecraft to determine the location of ground-based transmitters is in tracking high-altitude balloons for meteorological studies. A source of error in this application is reflection of the signal from the sea surface. Through propagating and signal analysis, the magnitude of the reflection-induced error in both Doppler frequency measurements and interferometer phase measurements was estimated. The theory of diffuse scattering from random surfaces was applied to obtain the power spectral density of the reflected signal. The processing of the combined direct and reflected signals was then analyzed to find the statistics of the measurement error. It was found that the error varies greatly during the satellite overpass and attains its maximum value at closest approach. The maximum values of interferometer phase error and Doppler frequency error found for the system configuration considered were comparable to thermal noise-induced error.
Saito, Masahide; Sano, Naoki; Shibata, Yuki; Kuriyama, Kengo; Komiyama, Takafumi; Marino, Kan; Aoki, Shinichi; Ashizawa, Kazunari; Yoshizawa, Kazuya; Onishi, Hiroshi
2018-05-01
The purpose of this study was to compare the MLC error sensitivity of various measurement devices for VMAT pre-treatment quality assurance (QA). This study used four QA devices (Scandidos Delta4, PTW 2D-array, iRT systems IQM, and PTW Farmer chamber). Nine retrospective VMAT plans were used and nine MLC error plans were generated for all nine original VMAT plans. The IQM and Farmer chamber were evaluated using the cumulative signal difference between the baseline and error-induced measurements. In addition, to investigate the sensitivity of the Delta4 device and the 2D-array, global gamma analysis (1%/1, 2%/2, and 3%/3 mm), dose difference (1%, 2%, and 3%) were used between the baseline and error-induced measurements. Some deviations of the MLC error sensitivity for the evaluation metrics and MLC error ranges were observed. For the two ionization devices, the sensitivity of the IQM was significantly better than that of the Farmer chamber (P < 0.01) while both devices had good linearly correlation between the cumulative signal difference and the magnitude of MLC errors. The pass rates decreased as the magnitude of the MLC error increased for both Delta4 and 2D-array. However, the small MLC error for small aperture sizes, such as for lung SBRT, could not be detected using the loosest gamma criteria (3%/3 mm). Our results indicate that DD could be more useful than gamma analysis for daily MLC QA, and that a large-area ionization chamber has a greater advantage for detecting systematic MLC error because of the large sensitive volume, while the other devices could not detect this error for some cases with a small range of MLC error. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Duan, Wansuo; Zhao, Peng
2017-04-01
Within the Zebiak-Cane model, the nonlinear forcing singular vector (NFSV) approach is used to investigate the role of model errors in the "Spring Predictability Barrier" (SPB) phenomenon within ENSO predictions. NFSV-related errors have the largest negative effect on the uncertainties of El Niño predictions. NFSV errors can be classified into two types: the first is characterized by a zonal dipolar pattern of SST anomalies (SSTA), with the western poles centered in the equatorial central-western Pacific exhibiting positive anomalies and the eastern poles in the equatorial eastern Pacific exhibiting negative anomalies; and the second is characterized by a pattern almost opposite the first type. The first type of error tends to have the worst effects on El Niño growth-phase predictions, whereas the latter often yields the largest negative effects on decaying-phase predictions. The evolution of prediction errors caused by NFSV-related errors exhibits prominent seasonality, with the fastest error growth in the spring and/or summer seasons; hence, these errors result in a significant SPB related to El Niño events. The linear counterpart of NFSVs, the (linear) forcing singular vector (FSV), induces a less significant SPB because it contains smaller prediction errors. Random errors cannot generate a SPB for El Niño events. These results show that the occurrence of an SPB is related to the spatial patterns of tendency errors. The NFSV tendency errors cause the most significant SPB for El Niño events. In addition, NFSVs often concentrate these large value errors in a few areas within the equatorial eastern and central-western Pacific, which likely represent those areas sensitive to El Niño predictions associated with model errors. Meanwhile, these areas are also exactly consistent with the sensitive areas related to initial errors determined by previous studies. This implies that additional observations in the sensitive areas would not only improve the accuracy of the initial field but also promote the reduction of model errors to greatly improve ENSO forecasts.
Towards a Framework for Managing Risk Associated with Technology-Induced Error.
Borycki, Elizabeth M; Kushniruk, Andre W
2017-01-01
Health information technologies (HIT) promised to streamline and modernize healthcare processes. However, a growing body of research has indicated that if such technologies are not designed, implemented or maintained properly this may lead to an increased incidence of new types of errors which the authors have referred to as "technology-induced errors". In this paper, framework is presented that can be used to manage HIT risk. The framework considers the reduction of technology-induced errors at different stages by managing risks associated with the implementation of HIT. Frameworks that allow health information technology managers to employ proactive and preventative approaches that can be used to manage the risks associated with technology-induced errors are critical to improving HIT safety and managing risk associated with implementing new technologies.
Relative peripheral hyperopic defocus alters central refractive development in infant monkeys
Smith, Earl L.; Hung, Li-Fang; Huang, Juan
2009-01-01
Understanding the role of peripheral defocus on central refractive development is critical because refractive errors can vary significantly with eccentricity and peripheral refractions have been implicated in the genesis of central refractive errors in humans. Two rearing strategies were used to determine whether peripheral hyperopia alters central refractive development in rhesus monkeys. In intact eyes, lens-induced relative peripheral hyperopia produced central axial myopia. Moreover, eliminating the fovea by laser photoablation did not prevent compensating myopic changes in response to optically imposed hyperopia. These results show that peripheral refractive errors can have a substantial impact on central refractive development in primates. PMID:19632261
Tabernero, Juan; Vazquez, Daniel; Seidemann, Anne; Uttenweiler, Dietmar; Schaeffel, Frank
2009-08-01
The recent observation that central refractive development might be controlled by the refractive errors in the periphery, also in primates, revived the interest in the peripheral optics of the eye. We optimized an eccentric photorefractor to measure the peripheral refractive error in the vertical pupil meridian over the horizontal visual field (from -45 degrees to 45 degrees ), with and without myopic spectacle correction. Furthermore, a newly designed radial refractive gradient lens (RRG lens) that induces increasing myopia in all radial directions from the center was tested. We found that for the geometry of our measurement setup conventional spectacles induced significant relative hyperopia in the periphery, although its magnitude varied greatly among different spectacle designs and subjects. In contrast, the newly designed RRG lens induced relative peripheral myopia. These results are of interest to analyze the effect that different optical corrections might have on the emmetropization process.
Shimansky, Y P
2011-05-01
It is well known from numerous studies that perception can be significantly affected by intended action in many everyday situations, indicating that perception and related decision-making is not a simple, one-way sequence, but a complex iterative cognitive process. However, the underlying functional mechanisms are yet unclear. Based on an optimality approach, a quantitative computational model of one such mechanism has been developed in this study. It is assumed in the model that significant uncertainty about task-related parameters of the environment results in parameter estimation errors and an optimal control system should minimize the cost of such errors in terms of the optimality criterion. It is demonstrated that, if the cost of a parameter estimation error is significantly asymmetrical with respect to error direction, the tendency to minimize error cost creates a systematic deviation of the optimal parameter estimate from its maximum likelihood value. Consequently, optimization of parameter estimate and optimization of control action cannot be performed separately from each other under parameter uncertainty combined with asymmetry of estimation error cost, thus making the certainty equivalence principle non-applicable under those conditions. A hypothesis that not only the action, but also perception itself is biased by the above deviation of parameter estimate is supported by ample experimental evidence. The results provide important insights into the cognitive mechanisms of interaction between sensory perception and planning an action under realistic conditions. Implications for understanding related functional mechanisms of optimal control in the CNS are discussed.
How Alterations in the Cdt1 Expression Lead to Gene Amplification in Breast Cancer
2011-07-01
absence of extrinsic DNA damage. We measured the TLS activity by measuring the mutation frequency in a supF gene (in a shuttle vector) subjected to UV...induced DNA damage before its introduction into the cells. Error-prone TLS activity will mutate the supF gene , which is scored by a blue-white colony...Figure 4A). Sequencing of the mutant supF genes , revealed a mutation spectrum consistent with error prone TLS (Supplemental Table 1). Significantly
Pointing error analysis of Risley-prism-based beam steering system.
Zhou, Yuan; Lu, Yafei; Hei, Mo; Liu, Guangcan; Fan, Dapeng
2014-09-01
Based on the vector form Snell's law, ray tracing is performed to quantify the pointing errors of Risley-prism-based beam steering systems, induced by component errors, prism orientation errors, and assembly errors. Case examples are given to elucidate the pointing error distributions in the field of regard and evaluate the allowances of the error sources for a given pointing accuracy. It is found that the assembly errors of the second prism will result in more remarkable pointing errors in contrast with the first one. The pointing errors induced by prism tilt depend on the tilt direction. The allowances of bearing tilt and prism tilt are almost identical if the same pointing accuracy is planned. All conclusions can provide a theoretical foundation for practical works.
Tran, Nina; Chiu, Sara; Tian, Yibin; Wildsoet, Christine F.
2009-01-01
Purpose This study sought further insight into the stimulus dependence of form deprivation myopia, a common response to retinal image degradation in young animals. Methods Each of 4 Bangerter diffusing filters (0.6, 0.1, <0.1, and LP (light perception only)) combined with clear plano lenses, as well as plano lenses alone, were fitted monocularly to 4-day-old chicks. Axial ocular dimensions and refractive errors were monitored over a 14-day treatment period, using high frequency A-scan ultrasonography and an autorefractor, respectively. Results Only the <0.1 and LP filters induced significant form deprivation myopia; these filters induced similarly large myopic shifts in refractive error (mean interocular differences ±SEM: -9.92 ±1.99, -7.26 ± 1.60 D respectively), coupled to significant increases in both vitreous chamber depths and optical axial lengths (p<0.001). The other 3 groups showed comparable, small changes in their ocular dimensions (p>0.05), and only small myopic shifts in refraction (<3.00 D). The myopia-inducing filters eliminated mid-and-high spatial frequency information. Conclusions Our results are consistent with emmetropization being tuned to mid-spatial frequencies. They also imply that form deprivation is not a graded phenomenon. PMID:18533221
Temperature Dependence of Faraday Effect-Induced Bias Error in a Fiber Optic Gyroscope
Li, Xuyou; Guang, Xingxing; Xu, Zhenlong; Li, Guangchun
2017-01-01
Improving the performance of interferometric fiber optic gyroscope (IFOG) in harsh environments, such as magnetic field and temperature field variation, is necessary for its practical applications. This paper presents an investigation of Faraday effect-induced bias error of IFOG under varying temperature. Jones matrix method is utilized to formulize the temperature dependence of Faraday effect-induced bias error. Theoretical results show that the Faraday effect-induced bias error changes with the temperature in the non-skeleton polarization maintaining (PM) fiber coil. This phenomenon is caused by the temperature dependence of linear birefringence and Verdet constant of PM fiber. Particularly, Faraday effect-induced bias errors of two polarizations always have opposite signs that can be compensated optically regardless of the changes of the temperature. Two experiments with a 1000 m non-skeleton PM fiber coil are performed, and the experimental results support these theoretical predictions. This study is promising for improving the bias stability of IFOG. PMID:28880203
Temperature Dependence of Faraday Effect-Induced Bias Error in a Fiber Optic Gyroscope.
Li, Xuyou; Liu, Pan; Guang, Xingxing; Xu, Zhenlong; Guan, Lianwu; Li, Guangchun
2017-09-07
Improving the performance of interferometric fiber optic gyroscope (IFOG) in harsh environments, such as magnetic field and temperature field variation, is necessary for its practical applications. This paper presents an investigation of Faraday effect-induced bias error of IFOG under varying temperature. Jones matrix method is utilized to formulize the temperature dependence of Faraday effect-induced bias error. Theoretical results show that the Faraday effect-induced bias error changes with the temperature in the non-skeleton polarization maintaining (PM) fiber coil. This phenomenon is caused by the temperature dependence of linear birefringence and Verdet constant of PM fiber. Particularly, Faraday effect-induced bias errors of two polarizations always have opposite signs that can be compensated optically regardless of the changes of the temperature. Two experiments with a 1000 m non-skeleton PM fiber coil are performed, and the experimental results support these theoretical predictions. This study is promising for improving the bias stability of IFOG.
Salgado, Eduardo; Ribeiro, Fernando; Oliveira, José
2015-06-01
The demands to which football players are exposed during the match may augment the risk of injury by decreasing the sense of joint position. This study aimed to assess the effect of pre-participation warm-up and fatigue induced by an official football match on the knee-joint-position sense of football players. Fourteen semi-professional male football players (mean age: 25.9±4.6 years old) volunteered in this study. The main outcome measures were rate of perceived exertion and knee-joint-position sense assessed at rest, immediately after a standard warm-up (duration 25 min), and immediately after a competitive football match (90 minutes duration). Perceived exertion increased significantly from rest to the other assessments (rest: 8.6±2.0; after warm-up: 12.1±2.1; after football match: 18.5±1.3; p<0.001). Compared to rest, absolute angular error decreased significantly after the warm-up (4.1°±2.2° vs. 2.0°±1.0°; p=0.0045). After the match, absolute angular error (8.7°±3.8°) increased significantly comparatively to both rest (p=0.001) and the end of warm-up (p<0.001). Relative error showed directional bias with an underestimation of the target position, which was higher after the football match compared to both rest (p<0.001) and after warm-up (p<0.001). The results indicate that knee-joint-position sense acuity was increased by pre-participation warm-up exercise and was decreased by football match-induced fatigue. Warm-up exercises could contribute to knee injury prevention, whereas the deleterious effect of match-induced fatigue on the sensorimotor system could ultimately contribute to knee instability and injury. Copyright © 2014 Elsevier B.V. All rights reserved.
Signal-Induced Noise Effects in a Photon Counting System for Stratospheric Ozone Measurement
NASA Technical Reports Server (NTRS)
Harper, David B.; DeYoung, Russell J.
1998-01-01
A significant source of error in making atmospheric differential absorption lidar ozone measurements is the saturation of the photomultiplier tube by the strong, near field light return. Some time after the near field light signal is gone, the photomultiplier tube gate is opened and a noise signal, called signal-induced noise, is observed. Research reported here gives experimental results from measurement of photomultiplier signal-induced noise. Results show that signal-induced noise has several decaying exponential signals, suggesting that electrons are slowly emitted from different surfaces internal to the photomultiplier tube.
Anomalous annealing of floating gate errors due to heavy ion irradiation
NASA Astrophysics Data System (ADS)
Yin, Yanan; Liu, Jie; Sun, Youmei; Hou, Mingdong; Liu, Tianqi; Ye, Bing; Ji, Qinggang; Luo, Jie; Zhao, Peixiong
2018-03-01
Using the heavy ions provided by the Heavy Ion Research Facility in Lanzhou (HIRFL), the annealing of heavy-ion induced floating gate (FG) errors in 34 nm and 25 nm NAND Flash memories has been studied. The single event upset (SEU) cross section of FG and the evolution of the errors after irradiation depending on the ion linear energy transfer (LET) values, data pattern and feature size of the device are presented. Different rates of annealing for different ion LET and different pattern are observed in 34 nm and 25 nm memories. The variation of the percentage of different error patterns in 34 nm and 25 nm memories with annealing time shows that the annealing of FG errors induced by heavy-ion in memories will mainly take place in the cells directly hit under low LET ion exposure and other cells affected by heavy ions when the ion LET is higher. The influence of Multiple Cell Upsets (MCUs) on the annealing of FG errors is analyzed. MCUs with high error multiplicity which account for the majority of the errors can induce a large percentage of annealed errors.
Post-error Brain Activity Correlates With Incidental Memory for Negative Words
Senderecka, Magdalena; Ociepka, Michał; Matyjek, Magdalena; Kroczek, Bartłomiej
2018-01-01
The present study had three main objectives. First, we aimed to evaluate whether short-duration affective states induced by negative and positive words can lead to increased error-monitoring activity relative to a neutral task condition. Second, we intended to determine whether such an enhancement is limited to words of specific valence or is a general response to arousing material. Third, we wanted to assess whether post-error brain activity is associated with incidental memory for negative and/or positive words. Participants performed an emotional stop-signal task that required response inhibition to negative, positive or neutral nouns while EEG was recorded. Immediately after the completion of the task, they were instructed to recall as many of the presented words as they could in an unexpected free recall test. We observed significantly greater brain activity in the error-positivity (Pe) time window in both negative and positive trials. The error-related negativity amplitudes were comparable in both the neutral and emotional arousing trials, regardless of their valence. Regarding behavior, increased processing of emotional words was reflected in better incidental recall. Importantly, the memory performance for negative words was positively correlated with the Pe amplitude, particularly in the negative condition. The source localization analysis revealed that the subsequent memory recall for negative words was associated with widespread bilateral brain activity in the dorsal anterior cingulate cortex and in the medial frontal gyrus, which was registered in the Pe time window during negative trials. The present study has several important conclusions. First, it indicates that the emotional enhancement of error monitoring, as reflected by the Pe amplitude, may be induced by stimuli with symbolic, ontogenetically learned emotional significance. Second, it indicates that the emotion-related enhancement of the Pe occurs across both negative and positive conditions, thus it is preferentially driven by the arousal content of an affective stimuli. Third, our findings suggest that enhanced error monitoring and facilitated recall of negative words may both reflect responsivity to negative events. More speculatively, they can also indicate that post-error activity of the medial prefrontal cortex may selectively support encoding for negative stimuli and contribute to their privileged access to memory. PMID:29867408
Functional language shift to the right hemisphere in patients with language-eloquent brain tumors.
Krieg, Sandro M; Sollmann, Nico; Hauck, Theresa; Ille, Sebastian; Foerschler, Annette; Meyer, Bernhard; Ringel, Florian
2013-01-01
Language function is mainly located within the left hemisphere of the brain, especially in right-handed subjects. However, functional MRI (fMRI) has demonstrated changes of language organization in patients with left-sided perisylvian lesions to the right hemisphere. Because intracerebral lesions can impair fMRI, this study was designed to investigate human language plasticity with a virtual lesion model using repetitive navigated transcranial magnetic stimulation (rTMS). Fifteen patients with lesions of left-sided language-eloquent brain areas and 50 healthy and purely right-handed participants underwent bilateral rTMS language mapping via an object-naming task. All patients were proven to have left-sided language function during awake surgery. The rTMS-induced language errors were categorized into 6 different error types. The error ratio (induced errors/number of stimulations) was determined for each brain region on both hemispheres. A hemispheric dominance ratio was then defined for each region as the quotient of the error ratio (left/right) of the corresponding area of both hemispheres (ratio >1 = left dominant; ratio <1 = right dominant). Patients with language-eloquent lesions showed a statistically significantly lower ratio than healthy participants concerning "all errors" and "all errors without hesitations", which indicates a higher participation of the right hemisphere in language function. Yet, there was no cortical region with pronounced difference in language dominance compared to the whole hemisphere. This is the first study that shows by means of an anatomically accurate virtual lesion model that a shift of language function to the non-dominant hemisphere can occur.
Lenticular accommodation in relation to ametropia: the chick model.
Choh, Vivian; Sivak, Jacob G
2005-03-04
Our goal was to determine whether experimentally induced ametropias have an effect on lenticular accommodation and spherical aberration. Form-deprivation myopia and hyperopia were induced in one eye of hatchling chicks by application of a translucent goggle and +15 D lens, respectively. After 7 days, eyes were enucleated and lenses were optically scanned prior to accommodation, during accommodation, and after accommodation. Accommodation was induced by electrical stimulation of the ciliary nerve. Lenticular focal lengths for form-deprived eyes were significantly shorter than for their controls and accommodation-associated changes in focal length were significantly smaller in myopic eyes compared to their controls. For eyes imposed with +15 D blur, focal lengths were longer than those for their controls and accommodative changes were greater. Spherical aberration of the lens increased with accommodation in both form-deprived and lens-treated birds, but induction of ametropia had no effect on lenticular spherical aberration in general. Nonmonotonicity from lenticular spherical aberration increased during accommodation but effects of refractive error were equivocal. The crystalline lens contributes to refractive error changes of the eye both in the case of myopia and hyperopia. These changes are likely attributable to global changes in the size and shape of the eye.
Analysis of phase error effects in multishot diffusion-prepared turbo spin echo imaging
Cervantes, Barbara; Kooijman, Hendrik; Karampinos, Dimitrios C.
2017-01-01
Background To characterize the effect of phase errors on the magnitude and the phase of the diffusion-weighted (DW) signal acquired with diffusion-prepared turbo spin echo (dprep-TSE) sequences. Methods Motion and eddy currents were identified as the main sources of phase errors. An analytical expression for the effect of phase errors on the acquired signal was derived and verified using Bloch simulations, phantom, and in vivo experiments. Results Simulations and experiments showed that phase errors during the diffusion preparation cause both magnitude and phase modulation on the acquired data. When motion-induced phase error (MiPe) is accounted for (e.g., with motion-compensated diffusion encoding), the signal magnitude modulation due to the leftover eddy-current-induced phase error cannot be eliminated by the conventional phase cycling and sum-of-squares (SOS) method. By employing magnitude stabilizers, the phase-error-induced magnitude modulation, regardless of its cause, was removed but the phase modulation remained. The in vivo comparison between pulsed gradient and flow-compensated diffusion preparations showed that MiPe needed to be addressed in multi-shot dprep-TSE acquisitions employing magnitude stabilizers. Conclusions A comprehensive analysis of phase errors in dprep-TSE sequences showed that magnitude stabilizers are mandatory in removing the phase error induced magnitude modulation. Additionally, when multi-shot dprep-TSE is employed the inconsistent signal phase modulation across shots has to be resolved before shot-combination is performed. PMID:28516049
Radiation-Hardened Solid-State Drive
NASA Technical Reports Server (NTRS)
Sheldon, Douglas J.
2010-01-01
A method is provided for a radiationhardened (rad-hard) solid-state drive for space mission memory applications by combining rad-hard and commercial off-the-shelf (COTS) non-volatile memories (NVMs) into a hybrid architecture. The architecture is controlled by a rad-hard ASIC (application specific integrated circuit) or a FPGA (field programmable gate array). Specific error handling and data management protocols are developed for use in a rad-hard environment. The rad-hard memories are smaller in overall memory density, but are used to control and manage radiation-induced errors in the main, and much larger density, non-rad-hard COTS memory devices. Small amounts of rad-hard memory are used as error buffers and temporary caches for radiation-induced errors in the large COTS memories. The rad-hard ASIC/FPGA implements a variety of error-handling protocols to manage these radiation-induced errors. The large COTS memory is triplicated for protection, and CRC-based counters are calculated for sub-areas in each COTS NVM array. These counters are stored in the rad-hard non-volatile memory. Through monitoring, rewriting, regeneration, triplication, and long-term storage, radiation-induced errors in the large NV memory are managed. The rad-hard ASIC/FPGA also interfaces with the external computer buses.
Nikolaitchik, Olga A.; Burdick, Ryan C.; Gorelick, Robert J.; Keele, Brandon F.; Hu, Wei-Shau; Pathak, Vinay K.
2016-01-01
Although the predominant effect of host restriction APOBEC3 proteins on HIV-1 infection is to block viral replication, they might inadvertently increase retroviral genetic variation by inducing G-to-A hypermutation. Numerous studies have disagreed on the contribution of hypermutation to viral genetic diversity and evolution. Confounding factors contributing to the debate include the extent of lethal (stop codon) and sublethal hypermutation induced by different APOBEC3 proteins, the inability to distinguish between G-to-A mutations induced by APOBEC3 proteins and error-prone viral replication, the potential impact of hypermutation on the frequency of retroviral recombination, and the extent to which viral recombination occurs in vivo, which can reassort mutations in hypermutated genomes. Here, we determined the effects of hypermutation on the HIV-1 recombination rate and its contribution to genetic variation through recombination to generate progeny genomes containing portions of hypermutated genomes without lethal mutations. We found that hypermutation did not significantly affect the rate of recombination, and recombination between hypermutated and wild-type genomes only increased the viral mutation rate by 3.9 × 10−5 mutations/bp/replication cycle in heterozygous virions, which is similar to the HIV-1 mutation rate. Since copackaging of hypermutated and wild-type genomes occurs very rarely in vivo, recombination between hypermutated and wild-type genomes does not significantly contribute to the genetic variation of replicating HIV-1. We also analyzed previously reported hypermutated sequences from infected patients and determined that the frequency of sublethal mutagenesis for A3G and A3F is negligible (4 × 10−21 and1 × 10−11, respectively) and its contribution to viral mutations is far below mutations generated during error-prone reverse transcription. Taken together, we conclude that the contribution of APOBEC3-induced hypermutation to HIV-1 genetic variation is substantially lower than that from mutations during error-prone replication. PMID:27186986
Delviks-Frankenberry, Krista A; Nikolaitchik, Olga A; Burdick, Ryan C; Gorelick, Robert J; Keele, Brandon F; Hu, Wei-Shau; Pathak, Vinay K
2016-05-01
Although the predominant effect of host restriction APOBEC3 proteins on HIV-1 infection is to block viral replication, they might inadvertently increase retroviral genetic variation by inducing G-to-A hypermutation. Numerous studies have disagreed on the contribution of hypermutation to viral genetic diversity and evolution. Confounding factors contributing to the debate include the extent of lethal (stop codon) and sublethal hypermutation induced by different APOBEC3 proteins, the inability to distinguish between G-to-A mutations induced by APOBEC3 proteins and error-prone viral replication, the potential impact of hypermutation on the frequency of retroviral recombination, and the extent to which viral recombination occurs in vivo, which can reassort mutations in hypermutated genomes. Here, we determined the effects of hypermutation on the HIV-1 recombination rate and its contribution to genetic variation through recombination to generate progeny genomes containing portions of hypermutated genomes without lethal mutations. We found that hypermutation did not significantly affect the rate of recombination, and recombination between hypermutated and wild-type genomes only increased the viral mutation rate by 3.9 × 10-5 mutations/bp/replication cycle in heterozygous virions, which is similar to the HIV-1 mutation rate. Since copackaging of hypermutated and wild-type genomes occurs very rarely in vivo, recombination between hypermutated and wild-type genomes does not significantly contribute to the genetic variation of replicating HIV-1. We also analyzed previously reported hypermutated sequences from infected patients and determined that the frequency of sublethal mutagenesis for A3G and A3F is negligible (4 × 10-21 and1 × 10-11, respectively) and its contribution to viral mutations is far below mutations generated during error-prone reverse transcription. Taken together, we conclude that the contribution of APOBEC3-induced hypermutation to HIV-1 genetic variation is substantially lower than that from mutations during error-prone replication.
NASA Astrophysics Data System (ADS)
Hu, Qing-Qing; Freier, Christian; Leykauf, Bastian; Schkolnik, Vladimir; Yang, Jun; Krutzik, Markus; Peters, Achim
2017-09-01
Precisely evaluating the systematic error induced by the quadratic Zeeman effect is important for developing atom interferometer gravimeters aiming at an accuracy in the μ Gal regime (1 μ Gal =10-8m /s2 ≈10-9g ). This paper reports on the experimental investigation of Raman spectroscopy-based magnetic field measurements and the evaluation of the systematic error in the gravimetric atom interferometer (GAIN) due to quadratic Zeeman effect. We discuss Raman duration and frequency step-size-dependent magnetic field measurement uncertainty, present vector light shift and tensor light shift induced magnetic field measurement offset, and map the absolute magnetic field inside the interferometer chamber of GAIN with an uncertainty of 0.72 nT and a spatial resolution of 12.8 mm. We evaluate the quadratic Zeeman-effect-induced gravity measurement error in GAIN as 2.04 μ Gal . The methods shown in this paper are important for precisely mapping the absolute magnetic field in vacuum and reducing the quadratic Zeeman-effect-induced systematic error in Raman transition-based precision measurements, such as atomic interferometer gravimeters.
NASA Technical Reports Server (NTRS)
Ramirez, Daniel Perez; Whiteman, David N.; Veselovskii, Igor; Kolgotin, Alexei; Korenskiy, Michael; Alados-Arboledas, Lucas
2013-01-01
In this work we study the effects of systematic and random errors on the inversion of multiwavelength (MW) lidar data using the well-known regularization technique to obtain vertically resolved aerosol microphysical properties. The software implementation used here was developed at the Physics Instrumentation Center (PIC) in Troitsk (Russia) in conjunction with the NASA/Goddard Space Flight Center. Its applicability to Raman lidar systems based on backscattering measurements at three wavelengths (355, 532 and 1064 nm) and extinction measurements at two wavelengths (355 and 532 nm) has been demonstrated widely. The systematic error sensitivity is quantified by first determining the retrieved parameters for a given set of optical input data consistent with three different sets of aerosol physical parameters. Then each optical input is perturbed by varying amounts and the inversion is repeated. Using bimodal aerosol size distributions, we find a generally linear dependence of the retrieved errors in the microphysical properties on the induced systematic errors in the optical data. For the retrievals of effective radius, number/surface/volume concentrations and fine-mode radius and volume, we find that these results are not significantly affected by the range of the constraints used in inversions. But significant sensitivity was found to the allowed range of the imaginary part of the particle refractive index. Our results also indicate that there exists an additive property for the deviations induced by the biases present in the individual optical data. This property permits the results here to be used to predict deviations in retrieved parameters when multiple input optical data are biased simultaneously as well as to study the influence of random errors on the retrievals. The above results are applied to questions regarding lidar design, in particular for the spaceborne multiwavelength lidar under consideration for the upcoming ACE mission.
Rosenfield, Mark; Hue, Jennifer E; Huang, Rae R; Bababekova, Yuliya
2012-03-01
Computer vision syndrome (CVS) is a complex of eye and vision problems related to computer use which has been reported in up to 90% of computer users. Ocular symptoms may include asthenopia, accommodative and vergence difficulties and dry eye. Previous studies have reported that uncorrected astigmatism may have a significant impact on symptoms of CVS. However, its effect on task performance is unclear. This study recorded symptoms after a 10 min period of reading from a computer monitor either through the habitual distance refractive correction or with a supplementary -1.00 or -2.00D oblique cylinder added over these lenses in 12 young, visually-normal subjects. Additionally, the distance correction condition was repeated to assess the repeatability of the symptom questionnaire. Subjects' reading speed and accuracy were monitored during the course of the 10 min trial. There was no significant difference in reading rate or the number of errors between the three astigmatic conditions. However, a significant change in symptoms was reported with the median total symptom scores for the 0, 1 and 2D astigmatic conditions being 2.0, 6.5 and 40.0, respectively (p < 0.0001). Further, the repeatability coefficient of the total symptom score following the repeated zero astigmatism condition was ± 13.46. The presence of induced astigmatism produced a significant increase in post-task symptoms but did not affect reading rate or the number of reading errors. The correction of small astigmatic refractive errors may be important in optimizing patient comfort during computer operation. Ophthalmic & Physiological Optics © 2011 The College of Optometrists.
Temporally-stable active precision mount for large optics.
Reinlein, Claudia; Damm, Christoph; Lange, Nicolas; Kamm, Andreas; Mohaupt, Matthias; Brady, Aoife; Goy, Matthias; Leonhard, Nina; Eberhardt, Ramona; Zeitner, Uwe; Tünnermann, Andreas
2016-06-13
We present a temporally-stable active mount to compensate for manufacturing-induced deformations of reflective optical components. In this paper, we introduce the design of the active mount, and its evaluation results for two sample mirrors: a quarter mirror of 115 × 105 × 9 mm3, and a full mirror of 228 × 210 × 9 mm3. The quarter mirror with 20 actuators shows a best wavefront error rms of 10 nm. Its installation position depending deformations are addressed by long-time measurements over 14 weeks indicating no significance of the orientation. Size-induced differences of the mount are studied by a full mirror with 80 manual actuators arranged in the same actuator pattern as the quarter mirror. This sample shows a wavefront error rms of (27±2) nm over a measurement period of 46 days. We conclude that the developed mount is suitable to compensate for manufacturing-induced deformations of large reflective optics, and likely to be included in the overall systems alignment procedure.
Global seasonal strain and stress models derived from GRACE loading, and their impact on seismicity
NASA Astrophysics Data System (ADS)
Chanard, K.; Fleitout, L.; Calais, E.; Craig, T. J.; Rebischung, P.; Avouac, J. P.
2017-12-01
Loading by continental water, atmosphere and oceans deforms the Earth at various spatio-temporal scales, inducing crustal and mantelic stress perturbations that may play a role in earthquake triggering.Deformation of the Earth by this surface loading is observed in GNSS position time series. While various models predict well vertical observations, explaining horizontal displacements remains challenging. We model the elastic deformation induced by loading derived from GRACE for coefficients 2 and higher. We estimate the degree-1 deformation field by comparison between predictions of our model and IGS-repro2 solutions at a globally distributed network of 700 GNSS sites, separating the horizontal and vertical components to avoid biases between components. The misfit between model and data is reduced compared to previous studies, particularly on the horizontal component. The associated geocenter motion time series are consistent with results derived from other datasets. We also discuss the impact on our results of systematic errors in GNSS geodetic products, in particular of the draconitic error.We then compute stress tensors time series induced by GRACE loads and discuss the potential link between large scale seasonal mass redistributions and seismicity. Within the crust, we estimate hydrologically induced stresses in the intraplate New Madrid Seismic Zone, where secular stressing rates are unmeasurably low. We show that a significant variation in the rate of micro-earthquakes at annual and multi-annual timescales coincides with stresses induced by hydrological loading in the upper Mississippi embayment, with no significant phase-lag, directly modulating regional seismicity. We also investigate pressure variations in the mantle transition zone and discuss potential correlations between the statistically significant observed seasonality of deep-focus earthquakes, most likely due to mineralogical transformations, and surface hydrological loading.
Reduction of the misinformation effect by arousal induced after learning.
English, Shaun M; Nielson, Kristy A
2010-11-01
Misinformation introduced after events have already occurred causes errors in later retrieval. Based on literature showing that arousal induced after learning enhances delayed retrieval, we investigated whether post-learning arousal can reduce the misinformation effect. 251 participants viewed four short film clips, each followed by a retention test, which for some participants included misinformation. Afterward, participants viewed another film clip that was either arousing or neutral. One week later, the arousal group recognized significantly more veridical details and endorsed significantly fewer misinformation items than the neutral group. The findings suggest that arousal induced after learning reduced source confusion, allowing participants to better retrieve accurate details and to better reject misinformation. Copyright © 2010 Elsevier B.V. All rights reserved.
2002-12-01
applications, vibration sources are numerous such as: ! Launch Loading ! Man-induced accelerations like on the Shuttle or space station ! Solar ...However, the lack of significant tracking errors during times when other actuators were stationary, and the fact that the local maximum tracking...
SIMulation of Medication Error induced by Clinical Trial drug labeling: the SIMME-CT study.
Dollinger, Cecile; Schwiertz, Vérane; Sarfati, Laura; Gourc-Berthod, Chloé; Guédat, Marie-Gabrielle; Alloux, Céline; Vantard, Nicolas; Gauthier, Noémie; He, Sophie; Kiouris, Elena; Caffin, Anne-Gaelle; Bernard, Delphine; Ranchon, Florence; Rioufol, Catherine
2016-06-01
To assess the impact of investigational drug labels on the risk of medication error in drug dispensing. A simulation-based learning program focusing on investigational drug dispensing was conducted. The study was undertaken in an Investigational Drugs Dispensing Unit of a University Hospital of Lyon, France. Sixty-three pharmacy workers (pharmacists, residents, technicians or students) were enrolled. Ten risk factors were selected concerning label information or the risk of confusion with another clinical trial. Each risk factor was scored independently out of 5: the higher the score, the greater the risk of error. From 400 labels analyzed, two groups were selected for the dispensing simulation: 27 labels with high risk (score ≥3) and 27 with low risk (score ≤2). Each question in the learning program was displayed as a simulated clinical trial prescription. Medication error was defined as at least one erroneous answer (i.e. error in drug dispensing). For each question, response times were collected. High-risk investigational drug labels correlated with medication error and slower response time. Error rates were significantly 5.5-fold higher for high-risk series. Error frequency was not significantly affected by occupational category or experience in clinical trials. SIMME-CT is the first simulation-based learning tool to focus on investigational drug labels as a risk factor for medication error. SIMME-CT was also used as a training tool for staff involved in clinical research, to develop medication error risk awareness and to validate competence in continuing medical education. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.
NASA Technical Reports Server (NTRS)
Mishchenko, M. I.; Lacis, A. A.; Travis, L. D.
1994-01-01
Although neglecting polarization and replacing the rigorous vector radiative transfer equation by its approximate scalar counterpart has no physical background, it is a widely used simplification when the incident light is unpolarized and only the intensity of the reflected light is to be computed. We employ accurate vector and scalar multiple-scattering calculations to perform a systematic study of the errors induced by the neglect of polarization in radiance calculations for a homogeneous, plane-parallel Rayleigh-scattering atmosphere (with and without depolarization) above a Lambertian surface. Specifically, we calculate percent errors in the reflected intensity for various directions of light incidence and reflection, optical thicknesses of the atmosphere, single-scattering albedos, depolarization factors, and surface albedos. The numerical data displayed can be used to decide whether or not the scalar approximation may be employed depending on the parameters of the problem. We show that the errors decrease with increasing depolarization factor and/or increasing surface albedo. For conservative or nearly conservative scattering and small surface albedos, the errors are maximum at optical thicknesses of about 1. The calculated errors may be too large for some practical applications, and, therefore, rigorous vector calculations should be employed whenever possible. However, if approximate scalar calculations are used, we recommend to avoid geometries involving phase angles equal or close to 0 deg and 90 deg, where the errors are especially significant. We propose a theoretical explanation of the large vector/scalar differences in the case of Rayleigh scattering. According to this explanation, the differences are caused by the particular structure of the Rayleigh scattering matrix and come from lower-order (except first-order) light scattering paths involving right scattering angles and right-angle rotations of the scattering plane.
Kinematic Analysis of Speech Sound Sequencing Errors Induced by Delayed Auditory Feedback.
Cler, Gabriel J; Lee, Jackson C; Mittelman, Talia; Stepp, Cara E; Bohland, Jason W
2017-06-22
Delayed auditory feedback (DAF) causes speakers to become disfluent and make phonological errors. Methods for assessing the kinematics of speech errors are lacking, with most DAF studies relying on auditory perceptual analyses, which may be problematic, as errors judged to be categorical may actually represent blends of sounds or articulatory errors. Eight typical speakers produced nonsense syllable sequences under normal and DAF (200 ms). Lip and tongue kinematics were captured with electromagnetic articulography. Time-locked acoustic recordings were transcribed, and the kinematics of utterances with and without perceived errors were analyzed with existing and novel quantitative methods. New multivariate measures showed that for 5 participants, kinematic variability for productions perceived to be error free was significantly increased under delay; these results were validated by using the spatiotemporal index measure. Analysis of error trials revealed both typical productions of a nontarget syllable and productions with articulatory kinematics that incorporated aspects of both the target and the perceived utterance. This study is among the first to characterize articulatory changes under DAF and provides evidence for different classes of speech errors, which may not be perceptually salient. New methods were developed that may aid visualization and analysis of large kinematic data sets. https://doi.org/10.23641/asha.5103067.
Kinematic Analysis of Speech Sound Sequencing Errors Induced by Delayed Auditory Feedback
Lee, Jackson C.; Mittelman, Talia; Stepp, Cara E.; Bohland, Jason W.
2017-01-01
Purpose Delayed auditory feedback (DAF) causes speakers to become disfluent and make phonological errors. Methods for assessing the kinematics of speech errors are lacking, with most DAF studies relying on auditory perceptual analyses, which may be problematic, as errors judged to be categorical may actually represent blends of sounds or articulatory errors. Method Eight typical speakers produced nonsense syllable sequences under normal and DAF (200 ms). Lip and tongue kinematics were captured with electromagnetic articulography. Time-locked acoustic recordings were transcribed, and the kinematics of utterances with and without perceived errors were analyzed with existing and novel quantitative methods. Results New multivariate measures showed that for 5 participants, kinematic variability for productions perceived to be error free was significantly increased under delay; these results were validated by using the spatiotemporal index measure. Analysis of error trials revealed both typical productions of a nontarget syllable and productions with articulatory kinematics that incorporated aspects of both the target and the perceived utterance. Conclusions This study is among the first to characterize articulatory changes under DAF and provides evidence for different classes of speech errors, which may not be perceptually salient. New methods were developed that may aid visualization and analysis of large kinematic data sets. Supplemental Material https://doi.org/10.23641/asha.5103067 PMID:28655038
Qiao-Grider, Ying; Hung, Li-Fang; Kee, Chea-Su; Ramamirtham, Ramkumar; Smith, Earl L
2010-08-23
We analyzed the contribution of individual ocular components to vision-induced ametropias in 210 rhesus monkeys. The primary contribution to refractive-error development came from vitreous chamber depth; a minor contribution from corneal power was also detected. However, there was no systematic relationship between refractive error and anterior chamber depth or between refractive error and any crystalline lens parameter. Our results are in good agreement with previous studies in humans, suggesting that the refractive errors commonly observed in humans are created by vision-dependent mechanisms that are similar to those operating in monkeys. This concordance emphasizes the applicability of rhesus monkeys in refractive-error studies. Copyright 2010 Elsevier Ltd. All rights reserved.
Qiao-Grider, Ying; Hung, Li-Fang; Kee, Chea-su; Ramamirtham, Ramkumar; Smith, Earl L.
2010-01-01
We analyzed the contribution of individual ocular components to vision-induced ametropias in 210 rhesus monkeys. The primary contribution to refractive-error development came from vitreous chamber depth; a minor contribution from corneal power was also detected. However, there was no systematic relationship between refractive error and anterior chamber depth or between refractive error and any crystalline lens parameter. Our results are in good agreement with previous studies in humans, suggesting that the refractive errors commonly observed in humans are created by vision-dependent mechanisms that are similar to those operating in monkeys. This concordance emphasizes the applicability of rhesus monkeys in refractive-error studies. PMID:20600237
Bergen, Silas; Sheppard, Lianne; Kaufman, Joel D.; Szpiro, Adam A.
2016-01-01
Summary Air pollution epidemiology studies are trending towards a multi-pollutant approach. In these studies, exposures at subject locations are unobserved and must be predicted using observed exposures at misaligned monitoring locations. This induces measurement error, which can bias the estimated health effects and affect standard error estimates. We characterize this measurement error and develop an analytic bias correction when using penalized regression splines to predict exposure. Our simulations show bias from multi-pollutant measurement error can be severe, and in opposite directions or simultaneously positive or negative. Our analytic bias correction combined with a non-parametric bootstrap yields accurate coverage of 95% confidence intervals. We apply our methodology to analyze the association of systolic blood pressure with PM2.5 and NO2 in the NIEHS Sister Study. We find that NO2 confounds the association of systolic blood pressure with PM2.5 and vice versa. Elevated systolic blood pressure was significantly associated with increased PM2.5 and decreased NO2. Correcting for measurement error bias strengthened these associations and widened 95% confidence intervals. PMID:27789915
Impact of SST Anomaly Events over the Kuroshio-Oyashio Extension on the "Summer Prediction Barrier"
NASA Astrophysics Data System (ADS)
Wu, Yujie; Duan, Wansuo
2018-04-01
The "summer prediction barrier" (SPB) of SST anomalies (SSTA) over the Kuroshio-Oyashio Extension (KOE) refers to the phenomenon that prediction errors of KOE-SSTA tend to increase rapidly during boreal summer, resulting in large prediction uncertainties. The fast error growth associated with the SPB occurs in the mature-to-decaying transition phase, which is usually during the August-September-October (ASO) season, of the KOE-SSTA events to be predicted. Thus, the role of KOE-SSTA evolutionary characteristics in the transition phase in inducing the SPB is explored by performing perfect model predictability experiments in a coupled model, indicating that the SSTA events with larger mature-to-decaying transition rates (Category-1) favor a greater possibility of yielding a more significant SPB than those events with smaller transition rates (Category-2). The KOE-SSTA events in Category-1 tend to have more significant anomalous Ekman pumping in their transition phase, resulting in larger prediction errors of vertical oceanic temperature advection associated with the SSTA events. Consequently, Category-1 events possess faster error growth and larger prediction errors. In addition, the anomalous Ekman upwelling (downwelling) in the ASO season also causes SSTA cooling (warming), accelerating the transition rates of warm (cold) KOE-SSTA events. Therefore, the SSTA transition rate and error growth rate are both related with the anomalous Ekman pumping of the SSTA events to be predicted in their transition phase. This may explain why the SSTA events transferring more rapidly from the mature to decaying phase tend to have a greater possibility of yielding a more significant SPB.
Scaling depth-induced wave-breaking in two-dimensional spectral wave models
NASA Astrophysics Data System (ADS)
Salmon, J. E.; Holthuijsen, L. H.; Zijlema, M.; van Vledder, G. Ph.; Pietrzak, J. D.
2015-03-01
Wave breaking in shallow water is still poorly understood and needs to be better parameterized in 2D spectral wave models. Significant wave heights over horizontal bathymetries are typically under-predicted in locally generated wave conditions and over-predicted in non-locally generated conditions. A joint scaling dependent on both local bottom slope and normalized wave number is presented and is shown to resolve these issues. Compared to the 12 wave breaking parameterizations considered in this study, this joint scaling demonstrates significant improvements, up to ∼50% error reduction, over 1D horizontal bathymetries for both locally and non-locally generated waves. In order to account for the inherent differences between uni-directional (1D) and directionally spread (2D) wave conditions, an extension of the wave breaking dissipation models is presented. By including the effects of wave directionality, rms-errors for the significant wave height are reduced for the best performing parameterizations in conditions with strong directional spreading. With this extension, our joint scaling improves modeling skill for significant wave heights over a verification data set of 11 different 1D laboratory bathymetries, 3 shallow lakes and 4 coastal sites. The corresponding averaged normalized rms-error for significant wave height in the 2D cases varied between 8% and 27%. In comparison, using the default setting with a constant scaling, as used in most presently operating 2D spectral wave models, gave equivalent errors between 15% and 38%.
Unreliable numbers: error and harm induced by bad design can be reduced by better design
Thimbleby, Harold; Oladimeji, Patrick; Cairns, Paul
2015-01-01
Number entry is a ubiquitous activity and is often performed in safety- and mission-critical procedures, such as healthcare, science, finance, aviation and in many other areas. We show that Monte Carlo methods can quickly and easily compare the reliability of different number entry systems. A surprising finding is that many common, widely used systems are defective, and induce unnecessary human error. We show that Monte Carlo methods enable designers to explore the implications of normal and unexpected operator behaviour, and to design systems to be more resilient to use error. We demonstrate novel designs with improved resilience, implying that the common problems identified and the errors they induce are avoidable. PMID:26354830
NASA Astrophysics Data System (ADS)
Zhang, Kuiyuan; Umehara, Shigehiro; Yamaguchi, Junki; Furuta, Jun; Kobayashi, Kazutoshi
2016-08-01
This paper analyzes how body bias and BOX region thickness affect soft error rates in 65-nm SOTB (Silicon on Thin BOX) and 28-nm UTBB (Ultra Thin Body and BOX) FD-SOI processes. Soft errors are induced by alpha-particle and neutron irradiation and the results are then analyzed by Monte Carlo based simulation using PHITS-TCAD. The alpha-particle-induced single event upset (SEU) cross-section and neutron-induced soft error rate (SER) obtained by simulation are consistent with measurement results. We clarify that SERs decreased in response to an increase in the BOX thickness for SOTB while SERs in UTBB are independent of BOX thickness. We also discover SOTB develops a higher tolerance to soft errors when reverse body bias is applied while UTBB become more susceptible.
Visuomotor adaptation needs a validation of prediction error by feedback error
Gaveau, Valérie; Prablanc, Claude; Laurent, Damien; Rossetti, Yves; Priot, Anne-Emmanuelle
2014-01-01
The processes underlying short-term plasticity induced by visuomotor adaptation to a shifted visual field are still debated. Two main sources of error can induce motor adaptation: reaching feedback errors, which correspond to visually perceived discrepancies between hand and target positions, and errors between predicted and actual visual reafferences of the moving hand. These two sources of error are closely intertwined and difficult to disentangle, as both the target and the reaching limb are simultaneously visible. Accordingly, the goal of the present study was to clarify the relative contributions of these two types of errors during a pointing task under prism-displaced vision. In “terminal feedback error” condition, viewing of their hand by subjects was allowed only at movement end, simultaneously with viewing of the target. In “movement prediction error” condition, viewing of the hand was limited to movement duration, in the absence of any visual target, and error signals arose solely from comparisons between predicted and actual reafferences of the hand. In order to prevent intentional corrections of errors, a subthreshold, progressive stepwise increase in prism deviation was used, so that subjects remained unaware of the visual deviation applied in both conditions. An adaptive aftereffect was observed in the “terminal feedback error” condition only. As far as subjects remained unaware of the optical deviation and self-assigned pointing errors, prediction error alone was insufficient to induce adaptation. These results indicate a critical role of hand-to-target feedback error signals in visuomotor adaptation; consistent with recent neurophysiological findings, they suggest that a combination of feedback and prediction error signals is necessary for eliciting aftereffects. They also suggest that feedback error updates the prediction of reafferences when a visual perturbation is introduced gradually and cognitive factors are eliminated or strongly attenuated. PMID:25408644
Error decomposition and estimation of inherent optical properties.
Salama, Mhd Suhyb; Stein, Alfred
2009-09-10
We describe a methodology to quantify and separate the errors of inherent optical properties (IOPs) derived from ocean-color model inversion. Their total error is decomposed into three different sources, namely, model approximations and inversion, sensor noise, and atmospheric correction. Prior information on plausible ranges of observation, sensor noise, and inversion goodness-of-fit are employed to derive the posterior probability distribution of the IOPs. The relative contribution of each error component to the total error budget of the IOPs, all being of stochastic nature, is then quantified. The method is validated with the International Ocean Colour Coordinating Group (IOCCG) data set and the NASA bio-Optical Marine Algorithm Data set (NOMAD). The derived errors are close to the known values with correlation coefficients of 60-90% and 67-90% for IOCCG and NOMAD data sets, respectively. Model-induced errors inherent to the derived IOPs are between 10% and 57% of the total error, whereas atmospheric-induced errors are in general above 43% and up to 90% for both data sets. The proposed method is applied to synthesized and in situ measured populations of IOPs. The mean relative errors of the derived values are between 2% and 20%. A specific error table to the Medium Resolution Imaging Spectrometer (MERIS) sensor is constructed. It serves as a benchmark to evaluate the performance of the atmospheric correction method and to compute atmospheric-induced errors. Our method has a better performance and is more appropriate to estimate actual errors of ocean-color derived products than the previously suggested methods. Moreover, it is generic and can be applied to quantify the error of any derived biogeophysical parameter regardless of the used derivation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hartley, R.; Kartz, M.; Behrendt, W.
1996-10-01
The laser wavefront of the NIF Beamlet demonstration system is corrected for static aberrations with a wavefront control system. The system operates closed loop with a probe beam prior to a shot and has a loop bandwidth of about 3 Hz. However, until recently the wavefront control system was disabled several minutes prior to the shot to allow time to manually reconfigure its attenuators and probe beam insertion mechanism to shot mode. Thermally-induced dynamic variations in gas density in the Beamlet main beam line produce significant wavefront error. After about 5-8 seconds, the wavefront error has increased to a new,more » higher level due to turbulence- induced aberrations no longer being corrected- This implies that there is a turbulence-induced aberration noise bandwidth of less than one Hertz, and that the wavefront controller could correct for the majority of turbulence-induced aberration (about one- third wave) by automating its reconfiguration to occur within one second of the shot, This modification was recently implemented on Beamlet; we call this modification the t{sub 0}-1 system.« less
Orifice-induced pressure error studies in Langley 7- by 10-foot high-speed tunnel
NASA Technical Reports Server (NTRS)
Plentovich, E. B.; Gloss, B. B.
1986-01-01
For some time it has been known that the presence of a static pressure measuring hole will disturb the local flow field in such a way that the sensed static pressure will be in error. The results of previous studies aimed at studying the error induced by the pressure orifice were for relatively low Reynolds number flows. Because of the advent of high Reynolds number transonic wind tunnels, a study was undertaken to assess the magnitude of this error at high Reynolds numbers than previously published and to study a possible method of eliminating this pressure error. This study was conducted in the Langley 7- by 10-Foot High-Speed Tunnel on a flat plate. The model was tested at Mach numbers from 0.40 to 0.72 and at Reynolds numbers from 7.7 x 1,000,000 to 11 x 1,000,000 per meter (2.3 x 1,000,000 to 3.4 x 1,000,000 per foot), respectively. The results indicated that as orifice size increased, the pressure error also increased but that a porous metal (sintered metal) plug inserted in an orifice could greatly reduce the pressure error induced by the orifice.
Functional Language Shift to the Right Hemisphere in Patients with Language-Eloquent Brain Tumors
Krieg, Sandro M.; Sollmann, Nico; Hauck, Theresa; Ille, Sebastian; Foerschler, Annette; Meyer, Bernhard; Ringel, Florian
2013-01-01
Objectives Language function is mainly located within the left hemisphere of the brain, especially in right-handed subjects. However, functional MRI (fMRI) has demonstrated changes of language organization in patients with left-sided perisylvian lesions to the right hemisphere. Because intracerebral lesions can impair fMRI, this study was designed to investigate human language plasticity with a virtual lesion model using repetitive navigated transcranial magnetic stimulation (rTMS). Experimental design Fifteen patients with lesions of left-sided language-eloquent brain areas and 50 healthy and purely right-handed participants underwent bilateral rTMS language mapping via an object-naming task. All patients were proven to have left-sided language function during awake surgery. The rTMS-induced language errors were categorized into 6 different error types. The error ratio (induced errors/number of stimulations) was determined for each brain region on both hemispheres. A hemispheric dominance ratio was then defined for each region as the quotient of the error ratio (left/right) of the corresponding area of both hemispheres (ratio >1 = left dominant; ratio <1 = right dominant). Results Patients with language-eloquent lesions showed a statistically significantly lower ratio than healthy participants concerning “all errors” and “all errors without hesitations”, which indicates a higher participation of the right hemisphere in language function. Yet, there was no cortical region with pronounced difference in language dominance compared to the whole hemisphere. Conclusions This is the first study that shows by means of an anatomically accurate virtual lesion model that a shift of language function to the non-dominant hemisphere can occur. PMID:24069410
Protective effects of pseudoginsenoside-F11 on methamphetamine-induced neurotoxicity in mice.
Wu, Chun Fu; Liu, Yan Li; Song, Ming; Liu, Wen; Wang, Jin Hui; Li, Xian; Yang, Jing Yu
2003-08-01
In the present study, pseudoginsenoside-F(11) (PF(11)), a saponin that existed in American ginseng, was studied on its protective effect on methamphetamine (MA)-induced behavioral and neurochemical toxicities in mice. MA was intraperitoneally administered at the dose of 10 mg/kg four times at 2-h intervals, and PF(11) was orally administered at the doses of 4 and 8 mg/kg two times at 4-h intervals, 60 min prior to MA administration. The results showed that PF(11) did not significantly influence, but greatly ameliorated, the anxiety-like behavior induced by MA in the light-dark box task. In the forced swimming task, PF(11) significantly shortened the prolonged immobility time induced by MA. In the appetitively motivated T-maze task, PF(11) greatly shortened MA-induced prolonged latency and decreased the error counts. Similar results were also observed in the Morris water maze task. PF(11) significantly shortened the escape latency prolonged by MA. There were significant decreases in the contents of dopamine (DA), 3,4-dihydroxyphenacetic acid (DOPAC), homovanillic acid (HVA), and 5-hydroxyindoacetic acid (5-HIAA) in the brain of MA-treated mice. PF(11) could partially, but significantly, antagonize MA-induced decreases of DA. The above results demonstrate that PF(11) is effective in protection of MA-induced neurotoxicity and also suggest that natural products, such as ginseng, might be potential candidates for the prevention and treatment of the neurological disorders induced by MA abuse.
Patton, James L; Stoykov, Mary Ellen; Kovic, Mark; Mussa-Ivaldi, Ferdinando A
2006-01-01
This investigation is one in a series of studies that address the possibility of stroke rehabilitation using robotic devices to facilitate "adaptive training." Healthy subjects, after training in the presence of systematically applied forces, typically exhibit a predictable "after-effect." A critical question is whether this adaptive characteristic is preserved following stroke so that it might be exploited for restoring function. Another important question is whether subjects benefit more from training forces that enhance their errors than from forces that reduce their errors. We exposed hemiparetic stroke survivors and healthy age-matched controls to a pattern of disturbing forces that have been found by previous studies to induce a dramatic adaptation in healthy individuals. Eighteen stroke survivors made 834 movements in the presence of a robot-generated force field that pushed their hands proportional to its speed and perpendicular to its direction of motion--either clockwise or counterclockwise. We found that subjects could adapt, as evidenced by significant after-effects. After-effects were not correlated with the clinical scores that we used for measuring motor impairment. Further examination revealed that significant improvements occurred only when the training forces magnified the original errors, and not when the training forces reduced the errors or were zero. Within this constrained experimental task we found that error-enhancing therapy (as opposed to guiding the limb closer to the correct path) to be more effective than therapy that assisted the subject.
A practical method of estimating standard error of age in the fission track dating method
Johnson, N.M.; McGee, V.E.; Naeser, C.W.
1979-01-01
A first-order approximation formula for the propagation of error in the fission track age equation is given by PA = C[P2s+P2i+P2??-2rPsPi] 1 2, where PA, Ps, Pi and P?? are the percentage error of age, of spontaneous track density, of induced track density, and of neutron dose, respectively, and C is a constant. The correlation, r, between spontaneous are induced track densities is a crucial element in the error analysis, acting generally to improve the standard error of age. In addition, the correlation parameter r is instrumental is specifying the level of neutron dose, a controlled variable, which will minimize the standard error of age. The results from the approximation equation agree closely with the results from an independent statistical model for the propagation of errors in the fission-track dating method. ?? 1979.
Temporal Decompostion of a Distribution System Quasi-Static Time-Series Simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mather, Barry A; Hunsberger, Randolph J
This paper documents the first phase of an investigation into reducing runtimes of complex OpenDSS models through parallelization. As the method seems promising, future work will quantify - and further mitigate - errors arising from this process. In this initial report, we demonstrate how, through the use of temporal decomposition, the run times of a complex distribution-system-level quasi-static time series simulation can be reduced roughly proportional to the level of parallelization. Using this method, the monolithic model runtime of 51 hours was reduced to a minimum of about 90 minutes. As expected, this comes at the expense of control- andmore » voltage-errors at the time-slice boundaries. All evaluations were performed using a real distribution circuit model with the addition of 50 PV systems - representing a mock complex PV impact study. We are able to reduce induced transition errors through the addition of controls initialization, though small errors persist. The time savings with parallelization are so significant that we feel additional investigation to reduce control errors is warranted.« less
Suppression of vapor cell temperature error for spin-exchange-relaxation-free magnetometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Jixi, E-mail: lujixi@buaa.edu.cn; Qian, Zheng; Fang, Jiancheng
2015-08-15
This paper presents a method to reduce the vapor cell temperature error of the spin-exchange-relaxation-free (SERF) magnetometer. The fluctuation of cell temperature can induce variations of the optical rotation angle, resulting in a scale factor error of the SERF magnetometer. In order to suppress this error, we employ the variation of the probe beam absorption to offset the variation of the optical rotation angle. The theoretical discussion of our method indicates that the scale factor error introduced by the fluctuation of the cell temperature could be suppressed by setting the optical depth close to one. In our experiment, we adjustmore » the probe frequency to obtain various optical depths and then measure the variation of scale factor with respect to the corresponding cell temperature changes. Our experimental results show a good agreement with our theoretical analysis. Under our experimental condition, the error has been reduced significantly compared with those when the probe wavelength is adjusted to maximize the probe signal. The cost of this method is the reduction of the scale factor of the magnetometer. However, according to our analysis, it only has minor effect on the sensitivity under proper operating parameters.« less
Regulation of error-prone translesion synthesis by Spartan/C1orf124
Kim, Myoung Shin; Machida, Yuka; Vashisht, Ajay A.; Wohlschlegel, James A.; Pang, Yuan-Ping; Machida, Yuichi J.
2013-01-01
Translesion synthesis (TLS) employs low fidelity polymerases to replicate past damaged DNA in a potentially error-prone process. Regulatory mechanisms that prevent TLS-associated mutagenesis are unknown; however, our recent studies suggest that the PCNA-binding protein Spartan plays a role in suppression of damage-induced mutagenesis. Here, we show that Spartan negatively regulates error-prone TLS that is dependent on POLD3, the accessory subunit of the replicative DNA polymerase Pol δ. We demonstrate that the putative zinc metalloprotease domain SprT in Spartan directly interacts with POLD3 and contributes to suppression of damage-induced mutagenesis. Depletion of Spartan induces complex formation of POLD3 with Rev1 and the error-prone TLS polymerase Pol ζ, and elevates mutagenesis that relies on POLD3, Rev1 and Pol ζ. These results suggest that Spartan negatively regulates POLD3 function in Rev1/Pol ζ-dependent TLS, revealing a previously unrecognized regulatory step in error-prone TLS. PMID:23254330
Myopia progression control lens reverses induced myopia in chicks.
Irving, Elizabeth L; Yakobchuk-Stanger, Cristina
2017-09-01
To determine whether lens induced myopia in chicks can be reversed or reduced by wearing myopia progression control lenses of the same nominal (central) power but different peripheral designs. Newly hatched chicks wore -10D Conventional lenses unilaterally for 7 days. The myopic chicks were then randomly divided into three groups: one fitted with Type 1 myopia progression control lenses, the second with Type 2 myopia progression control lenses and the third continued to wear Conventional lenses for seven more days. All lenses had -10D central power, but Type 1 and Type 2 lenses had differing peripheral designs; +2.75D and +1.32D power rise at pupil edge, respectively. Axial length and refractive error were measured on Days 0, 7 and 14. Analyses were performed on the mean differences between treated and untreated eyes. Refractive error and axial length differences between treated and untreated eyes were insignificant on Day 0. On Day 7 treated eyes were longer (T1; 0.44 ± 0.07 mm, T2; 0.27 ± 0.06 mm, C; 0.40 ± 0.06 mm) and more myopic (T1; -9.61 ± 0.52D, T2; -9.57 ± 0.61D, C; -9.50 ± 0.58D) than untreated eyes with no significant differences between treatment groups. On Day 14 myopia was reversed (+2.91 ± 1.08D), reduced (-3.83 ± 0.94D) or insignificantly increased (-11.89 ± 0.79D) in treated eyes of Type 1, Type 2 and Conventional treated chicks respectively. Relative changes in axial lengths (T1; -0.13 ± 0.09 mm, T2; 0.36 ± 0.09 mm, C; 0.56 ± 0.05 mm) were consistent with changes in refraction. Refractive error differences were significant for all group comparisons (p < 0.001). Type 1 length differences were significantly different from Conventional and Type 2 groups (p < 0.001). Myopia progression control lens designs can reverse lens-induced myopia in chicks. The effect is primarily due to axial length changes. Different lens designs produce different effects indicating that lens design is important in modifying refractive error. © 2017 The Authors. Ophthalmic and Physiological Optics published by John Wiley & Sons Ltd on behalf of College of Optometrists.
NASA Technical Reports Server (NTRS)
Ulvestad, J. S.
1989-01-01
Errors from a number of sources in astrometric very long baseline interferometry (VLBI) have been reduced in recent years through a variety of methods of calibration and modeling. Such reductions have led to a situation in which the extended structure of the natural radio sources used in VLBI is a significant error source in the effort to improve the accuracy of the radio reference frame. In the past, work has been done on individual radio sources to establish the magnitude of the errors caused by their particular structures. The results of calculations on 26 radio sources are reported in which an effort is made to determine the typical delay and delay-rate errors for a number of sources having different types of structure. It is found that for single observations of the types of radio sources present in astrometric catalogs, group-delay and phase-delay scatter in the 50 to 100 psec range due to source structure can be expected at 8.4 GHz on the intercontinental baselines available in the Deep Space Network (DSN). Delay-rate scatter of approx. 5 x 10(exp -15) sec sec(exp -1) (or approx. 0.002 mm sec (exp -1) is also expected. If such errors mapped directly into source position errors, they would correspond to position uncertainties of approx. 2 to 5 nrad, similar to the best position determinations in the current JPL VLBI catalog. With the advent of wider bandwidth VLBI systems on the large DSN antennas, the system noise will be low enough so that the structure-induced errors will be a significant part of the error budget. Several possibilities for reducing the structure errors are discussed briefly, although it is likely that considerable effort will have to be devoted to the structure problem in order to reduce the typical error by a factor of two or more.
Schaeffel, F; Bartmann, M; Hagel, G; Zrenner, E
1995-05-01
We have found that development of both deprivation-induced and lens-induced refractive errors in chickens implicates changes of the diurnal growth rhythms in the eye (Fig. 1). Because the major diurnal oscillator in the eye is expressed by the retinal dopamine/melatonin system, effects of drugs were studied that change retinal dopamine and/or serotonin levels. Vehicle-injected and drug-injected eyes treated with either translucent occluders or lenses were compared to focus on visual growth mechanisms. Retinal biogenic amine levels were measured at the end of each experiment by HPLC with electrochemical detection. For reserpine (which was most extensively studied) electroretinograms were recorded to test retinal function [Fig. 3 (C)] and catecholaminergic and serotonergic retinal neurons were observed by immunohistochemical labelling [Fig. 3(D)]. Deprivation myopia was readily altered by a single intravitreal injection of drugs that affected retinal dopamine or serotonin levels; reserpine which depleted both serotonin and dopamine stores blocked deprivation myopia very efficiently [Fig. 3(A)], whereas 5,7-dihydroxy-tryptamine (5,7-DHT), sulpiride, melatonin and Sch23390 could enhance deprivation myopia (Table 1, Fig. 5). In contrast to other procedures that were previously employed to block deprivation myopia (6-OHDA injections or continuous light) and which had no significant effect on lens-induced refractive errors, reserpine also affected lens-induced changes in eye growth. At lower doses, the effect was selective for negative lenses (Fig. 4). We found that the individual retinal dopamine levels were very variable among individuals but were correlated in both eyes of an animal; a similar variability was previously found with regard to deprivation myopia. To test a hypothesis raised by Li, Schaeffel, Kohler and Zrenner [(1992) Visual Neuroscience, 9, 483-492] that individual dopamine levels might determine the susceptibility to deprivation myopia, refractive errors were correlated with dopamine levels in occluded and untreated eyes of monocularly deprived chickens (Fig. 6). The hypothesis was rejected. Although it has been previously found that the static retinal tissue levels of dopamine are not altered by lens treatment, subtle changes in the ratio of DOPAC to dopamine were detected in the present study. The result indicates that retinal dopamine might be implicated also in lens-induced growth changes. Surprisingly, the changes were in the opposite direction for deprivation and negative lenses although both produce myopia. Currently, there is evidence that deprivation-induced and lens-induced refractive errors in chicks are produced by different mechanisms. However, findings (1), (3) and (5) suggest that there may also be common features. Although it has not yet been resolved how both mechanisms merge to produce the appropriate axial eye growth rates, we propose a scheme (Fig. 7).
Malinowski, Kathleen; McAvoy, Thomas J; George, Rohini; Dieterich, Sonja; D'Souza, Warren D
2013-07-01
To determine how best to time respiratory surrogate-based tumor motion model updates by comparing a novel technique based on external measurements alone to three direct measurement methods. Concurrently measured tumor and respiratory surrogate positions from 166 treatment fractions for lung or pancreas lesions were analyzed. Partial-least-squares regression models of tumor position from marker motion were created from the first six measurements in each dataset. Successive tumor localizations were obtained at a rate of once per minute on average. Model updates were timed according to four methods: never, respiratory surrogate-based (when metrics based on respiratory surrogate measurements exceeded confidence limits), error-based (when localization error ≥ 3 mm), and always (approximately once per minute). Radial tumor displacement prediction errors (mean ± standard deviation) for the four schema described above were 2.4 ± 1.2, 1.9 ± 0.9, 1.9 ± 0.8, and 1.7 ± 0.8 mm, respectively. The never-update error was significantly larger than errors of the other methods. Mean update counts over 20 min were 0, 4, 9, and 24, respectively. The same improvement in tumor localization accuracy could be achieved through any of the three update methods, but significantly fewer updates were required when the respiratory surrogate method was utilized. This study establishes the feasibility of timing image acquisitions for updating respiratory surrogate models without direct tumor localization.
Differential sea-state bias: A case study using TOPEX/POSEIDON data
NASA Technical Reports Server (NTRS)
Stewart, Robert H.; Devalla, B.
1994-01-01
We used selected data from the NASA altimeter TOPEX/POSEIDON to calculate differences in range measured by the C and Ku-band altimeters when the satellite overflew 5 to 15 m waves late at night. The range difference is due to free electrons in the ionosphere and to errors in sea-state bias. For the selected data the ionospheric influence on Ku range is less than 2 cm. Any difference in range over short horizontal distances is due only to a small along-track variability of the ionosphere and to errors in calculating the differential sea-state bias. We find that there is a barely detectable error in the bias in the geophysical data records. The wave-induced error in the ionospheric correction is less than 0.2% of significant wave height. The equivalent error in differential range is less than 1% of wave height. Errors in the differential sea-state bias calculations appear to be small even for extreme wave heights that greatly exceed the conditions on which the bias is based. The results also improved our confidence in the sea-state bias correction used for calculating the geophysical data records. Any error in the correction must influence Ku and C-band ranges almost equally.
Li, Beiwen; Liu, Ziping; Zhang, Song
2016-10-03
We propose a hybrid computational framework to reduce motion-induced measurement error by combining the Fourier transform profilometry (FTP) and phase-shifting profilometry (PSP). The proposed method is composed of three major steps: Step 1 is to extract continuous relative phase maps for each isolated object with single-shot FTP method and spatial phase unwrapping; Step 2 is to obtain an absolute phase map of the entire scene using PSP method, albeit motion-induced errors exist on the extracted absolute phase map; and Step 3 is to shift the continuous relative phase maps from Step 1 to generate final absolute phase maps for each isolated object by referring to the absolute phase map with error from Step 2. Experiments demonstrate the success of the proposed computational framework for measuring multiple isolated rapidly moving objects.
Performance Analysis of an Inter-Relay Co-operation in FSO Communication System
NASA Astrophysics Data System (ADS)
Khanna, Himanshu; Aggarwal, Mona; Ahuja, Swaran
2018-04-01
In this work, we analyze the outage and error performance of a one-way inter-relay assisted free space optical link. The assumption of the absence of direct link between the source and destination node is being made for the analysis, and the feasibility of such system configuration is studied. We consider the influence of path loss, atmospheric turbulence and pointing error impairments, and investigate the effect of these parameters on the system performance. The turbulence-induced fading is modeled by independent but not necessarily identically distributed gamma-gamma fading statistics. The closed-form expressions for outage probability and probability of error are derived and illustrated by numerical plots. It is concluded that the absence of line of sight path between source and destination nodes does not lead to significant performance degradation. Moreover, for the system model under consideration, interconnected relaying provides better error performance than the non-interconnected relaying and dual-hop serial relaying techniques.
Brodsky, Ethan K.; Klaers, Jessica L.; Samsonov, Alexey A.; Kijowski, Richard; Block, Walter F.
2014-01-01
Non-Cartesian imaging sequences and navigational methods can be more sensitive to scanner imperfections that have little impact on conventional clinical sequences, an issue which has repeatedly complicated the commercialization of these techniques by frustrating transitions to multi-center evaluations. One such imperfection is phase errors caused by resonant frequency shifts from eddy currents induced in the cryostat by time-varying gradients, a phenomemon known as B0 eddy currents. These phase errors can have a substantial impact on sequences that use ramp sampling, bipolar gradients, and readouts at varying azimuthal angles. We present a method for measuring and correcting phase errors from B0 eddy currents and examine the results on two different scanner models. This technique yields significant improvements in image quality for high-resolution joint imaging on certain scanners. The results suggest that correction of short time B0 eddy currents in manufacturer provided service routines would simplify adoption of non-Cartesian sampling methods. PMID:22488532
Pricing Employee Stock Options (ESOs) with Random Lattice
NASA Astrophysics Data System (ADS)
Chendra, E.; Chin, L.; Sukmana, A.
2018-04-01
Employee Stock Options (ESOs) are stock options granted by companies to their employees. Unlike standard options that can be traded by typical institutional or individual investors, employees cannot sell or transfer their ESOs to other investors. The sale restrictions may induce the ESO’s holder to exercise them earlier. In much cited paper, Hull and White propose a binomial lattice in valuing ESOs which assumes that employees will exercise voluntarily their ESOs if the stock price reaches a horizontal psychological barrier. Due to nonlinearity errors, the numerical pricing results oscillate significantly so they may lead to large pricing errors. In this paper, we use the random lattice method to price the Hull-White ESOs model. This method can reduce the nonlinearity error by aligning a layer of nodes of the random lattice with a psychological barrier.
IMRT QA: Selecting gamma criteria based on error detection sensitivity.
Steers, Jennifer M; Fraass, Benedick A
2016-04-01
The gamma comparison is widely used to evaluate the agreement between measurements and treatment planning system calculations in patient-specific intensity modulated radiation therapy (IMRT) quality assurance (QA). However, recent publications have raised concerns about the lack of sensitivity when employing commonly used gamma criteria. Understanding the actual sensitivity of a wide range of different gamma criteria may allow the definition of more meaningful gamma criteria and tolerance limits in IMRT QA. We present a method that allows the quantitative determination of gamma criteria sensitivity to induced errors which can be applied to any unique combination of device, delivery technique, and software utilized in a specific clinic. A total of 21 DMLC IMRT QA measurements (ArcCHECK®, Sun Nuclear) were compared to QA plan calculations with induced errors. Three scenarios were studied: MU errors, multi-leaf collimator (MLC) errors, and the sensitivity of the gamma comparison to changes in penumbra width. Gamma comparisons were performed between measurements and error-induced calculations using a wide range of gamma criteria, resulting in a total of over 20 000 gamma comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using 36 different gamma criteria. This study demonstrates that systematic errors and case-specific errors can be detected by the error curve analysis. Depending on the location of the error curve peak (e.g., not centered about zero), 3%/3 mm threshold = 10% at 90% pixels passing may miss errors as large as 15% MU errors and ±1 cm random MLC errors for some cases. As the dose threshold parameter was increased for a given %Diff/distance-to-agreement (DTA) setting, error sensitivity was increased by up to a factor of two for select cases. This increased sensitivity with increasing dose threshold was consistent across all studied combinations of %Diff/DTA. Criteria such as 2%/3 mm and 3%/2 mm with a 50% threshold at 90% pixels passing are shown to be more appropriately sensitive without being overly strict. However, a broadening of the penumbra by as much as 5 mm in the beam configuration was difficult to detect with commonly used criteria, as well as with the previously mentioned criteria utilizing a threshold of 50%. We have introduced the error curve method, an analysis technique which allows the quantitative determination of gamma criteria sensitivity to induced errors. The application of the error curve method using DMLC IMRT plans measured on the ArcCHECK® device demonstrated that large errors can potentially be missed in IMRT QA with commonly used gamma criteria (e.g., 3%/3 mm, threshold = 10%, 90% pixels passing). Additionally, increasing the dose threshold value can offer dramatic increases in error sensitivity. This approach may allow the selection of more meaningful gamma criteria for IMRT QA and is straightforward to apply to other combinations of devices and treatment techniques.
Quantifying the physical demands of a musical performance and their effects on performance quality.
Drinkwater, Eric J; Klopper, Christopher J
2010-06-01
This study investigated the effects of fatigue on performance quality induced by a prolonged musical performance. Ten participants prepared 10 min of repertoire for their chosen wind instrument that they played three times consecutively. Prior to the performance and within short breaks between performances, researchers collected heart rate, respiratory rate, blood pressure, blood lactate concentration, rating of perceived exertion (RPE), and rating of anxiety. All performances were audio recorded and later analysed for performance errors. Reliability in assessing performance errors was assessed by typical error of measure (TEM) of 15 repeat performances. Results indicate all markers of physical stress significantly increased by a moderate to large amount (4.6 to 62.2%; d = 0.50 to 1.54) once the performance began, while heart rate, respirations, and RPE continued to rise by a small to large amount (4.9 to 23.5%; d = 0.28 to 0.93) with each performance. Observed changes in performance between performances were well in excess of the TEM of 7.4%. There was a significant small (21%, d = 0.43) decrease in errors after the first performance; after the second performance, there was a significant large increase (70.4%, d = 1.14). The initial increase in physiological stress with corresponding decrease in errors after the first performance likely indicates "warming up," while the continued increase in markers of physical stress with dramatic decrement in performance quality likely indicates fatigue. Musicians may consider the relevance of physical fitness to maintaining performance quality over the duration of a performance.
Westendorff, Stephanie; Kuang, Shenbing; Taghizadeh, Bahareh; Donchin, Opher; Gail, Alexander
2015-04-01
Different error signals can induce sensorimotor adaptation during visually guided reaching, possibly evoking different neural adaptation mechanisms. Here we investigate reach adaptation induced by visual target errors without perturbing the actual or sensed hand position. We analyzed the spatial generalization of adaptation to target error to compare it with other known generalization patterns and simulated our results with a neural network model trained to minimize target error independent of prediction errors. Subjects reached to different peripheral visual targets and had to adapt to a sudden fixed-amplitude displacement ("jump") consistently occurring for only one of the reach targets. Subjects simultaneously had to perform contralateral unperturbed saccades, which rendered the reach target jump unnoticeable. As a result, subjects adapted by gradually decreasing reach errors and showed negative aftereffects for the perturbed reach target. Reach errors generalized to unperturbed targets according to a translational rather than rotational generalization pattern, but locally, not globally. More importantly, reach errors generalized asymmetrically with a skewed generalization function in the direction of the target jump. Our neural network model reproduced the skewed generalization after adaptation to target jump without having been explicitly trained to produce a specific generalization pattern. Our combined psychophysical and simulation results suggest that target jump adaptation in reaching can be explained by gradual updating of spatial motor goal representations in sensorimotor association networks, independent of learning induced by a prediction-error about the hand position. The simulations make testable predictions about the underlying changes in the tuning of sensorimotor neurons during target jump adaptation. Copyright © 2015 the American Physiological Society.
Westendorff, Stephanie; Kuang, Shenbing; Taghizadeh, Bahareh; Donchin, Opher
2015-01-01
Different error signals can induce sensorimotor adaptation during visually guided reaching, possibly evoking different neural adaptation mechanisms. Here we investigate reach adaptation induced by visual target errors without perturbing the actual or sensed hand position. We analyzed the spatial generalization of adaptation to target error to compare it with other known generalization patterns and simulated our results with a neural network model trained to minimize target error independent of prediction errors. Subjects reached to different peripheral visual targets and had to adapt to a sudden fixed-amplitude displacement (“jump”) consistently occurring for only one of the reach targets. Subjects simultaneously had to perform contralateral unperturbed saccades, which rendered the reach target jump unnoticeable. As a result, subjects adapted by gradually decreasing reach errors and showed negative aftereffects for the perturbed reach target. Reach errors generalized to unperturbed targets according to a translational rather than rotational generalization pattern, but locally, not globally. More importantly, reach errors generalized asymmetrically with a skewed generalization function in the direction of the target jump. Our neural network model reproduced the skewed generalization after adaptation to target jump without having been explicitly trained to produce a specific generalization pattern. Our combined psychophysical and simulation results suggest that target jump adaptation in reaching can be explained by gradual updating of spatial motor goal representations in sensorimotor association networks, independent of learning induced by a prediction-error about the hand position. The simulations make testable predictions about the underlying changes in the tuning of sensorimotor neurons during target jump adaptation. PMID:25609106
Error analysis and prevention of cosmic ion-induced soft errors in static CMOS RAMs
NASA Astrophysics Data System (ADS)
Diehl, S. E.; Ochoa, A., Jr.; Dressendorfer, P. V.; Koga, P.; Kolasinski, W. A.
1982-12-01
Cosmic ray interactions with memory cells are known to cause temporary, random, bit errors in some designs. The sensitivity of polysilicon gate CMOS static RAM designs to logic upset by impinging ions has been studied using computer simulations and experimental heavy ion bombardment. Results of the simulations are confirmed by experimental upset cross-section data. Analytical models have been extended to determine and evaluate design modifications which reduce memory cell sensitivity to cosmic ions. A simple design modification, the addition of decoupling resistance in the feedback path, is shown to produce static RAMs immune to cosmic ray-induced bit errors.
Error-Eliciting Problems: Fostering Understanding and Thinking
ERIC Educational Resources Information Center
Lim, Kien H.
2014-01-01
Student errors are springboards for analyzing, reasoning, and justifying. The mathematics education community recognizes the value of student errors, noting that "mistakes are seen not as dead ends but rather as potential avenues for learning." To induce specific errors and help students learn, choose tasks that might produce mistakes.…
Ring Laser Gyro Resonator Design
1994-06-20
vibration environment could cause errors in measured RLG rotation rates due to vibration (tilt) of the resonator mirrors . Vibration-induced mirror tilt...the RLG resonator design theoretically and calculated pertinent parameters such as the beam diameter at the aperture, cavity mirror alignment...sensitivities, and power loss due to aperture occlusion. The mirror vibration levels required to significantly affect the laser power were then calculated for
Souvestre, P A; Landrock, C K; Blaber, A P
2008-08-01
Human factors centered aviation accident analyses report that skill based errors are known to be cause of 80% of all accidents, decision making related errors 30% and perceptual errors 6%1. In-flight decision making error is a long time recognized major avenue leading to incidents and accidents. Through the past three decades, tremendous and costly efforts have been developed to attempt to clarify causation, roles and responsibility as well as to elaborate various preventative and curative countermeasures blending state of the art biomedical, technological advances and psychophysiological training strategies. In-flight related statistics have not been shown significantly changed and a significant number of issues remain not yet resolved. Fine Postural System and its corollary, Postural Deficiency Syndrome (PDS), both defined in the 1980's, are respectively neurophysiological and medical diagnostic models that reflect central neural sensory-motor and cognitive controls regulatory status. They are successfully used in complex neurotraumatology and related rehabilitation for over two decades. Analysis of clinical data taken over a ten-year period from acute and chronic post-traumatic PDS patients shows a strong correlation between symptoms commonly exhibited before, along side, or even after error, and sensory-motor or PDS related symptoms. Examples are given on how PDS related central sensory-motor control dysfunction can be correctly identified and monitored via a neurophysiological ocular-vestibular-postural monitoring system. The data presented provides strong evidence that a specific biomedical assessment methodology can lead to a better understanding of in-flight adaptive neurophysiological, cognitive and perceptual dysfunctional status that could induce in flight-errors. How relevant human factors can be identified and leveraged to maintain optimal performance will be addressed.
Effects of Reynolds number on orifice induced pressure error
NASA Technical Reports Server (NTRS)
Plentovich, E. B.; Gloss, B. B.
1982-01-01
Data previously reported for orifice induced pressure errors are extended to the case of higher Reynolds number flows, and a remedy is presented in the form of a porous metal plug for the orifice. Test orifices with apertures 0.330, 0.660, and 1.321 cm in diam. were fabricated on a flat plate for trials in the NASA Langley wind tunnel at Mach numbers 0.40-0.72. A boundary layer survey rake was also mounted on the flat plate to allow measurement of the total boundary layer pressures at the orifices. At the high Reynolds number flows studied, the orifice induced pressure error was found to be a function of the ratio of the orifice diameter to the boundary layer thickness. The error was effectively eliminated by the insertion of a porous metal disc set flush with the orifice outside surface.
NASA Technical Reports Server (NTRS)
Pak, Chan-Gi
2013-01-01
Modern aircraft employ a significant fraction of their weight in composite materials to reduce weight and improve performance. Aircraft aeroservoelastic models are typically characterized by significant levels of model parameter uncertainty due to the composite manufacturing process. Small modeling errors in the finite element model will eventually induce errors in the structural flexibility and mass, thus propagating into unpredictable errors in the unsteady aerodynamics and the control law design. One of the primary objectives of Multi Utility Technology Test-bed (MUTT) aircraft is the flight demonstration of active flutter suppression, and therefore in this study, the identification of the primary and secondary modes for the structural model tuning based on the flutter analysis of MUTT aircraft. The ground vibration test-validated structural dynamic finite element model of the MUTT aircraft is created in this study. The structural dynamic finite element model of MUTT aircraft is improved using the in-house Multi-disciplinary Design, Analysis, and Optimization tool. In this study, two different weight configurations of MUTT aircraft have been improved simultaneously in a single model tuning procedure.
Evaluation of lens distortion errors in video-based motion analysis
NASA Technical Reports Server (NTRS)
Poliner, Jeffrey; Wilmington, Robert; Klute, Glenn K.; Micocci, Angelo
1993-01-01
In an effort to study lens distortion errors, a grid of points of known dimensions was constructed and videotaped using a standard and a wide-angle lens. Recorded images were played back on a VCR and stored on a personal computer. Using these stored images, two experiments were conducted. Errors were calculated as the difference in distance from the known coordinates of the points to the calculated coordinates. The purposes of this project were as follows: (1) to develop the methodology to evaluate errors introduced by lens distortion; (2) to quantify and compare errors introduced by use of both a 'standard' and a wide-angle lens; (3) to investigate techniques to minimize lens-induced errors; and (4) to determine the most effective use of calibration points when using a wide-angle lens with a significant amount of distortion. It was seen that when using a wide-angle lens, errors from lens distortion could be as high as 10 percent of the size of the entire field of view. Even with a standard lens, there was a small amount of lens distortion. It was also found that the choice of calibration points influenced the lens distortion error. By properly selecting the calibration points and avoidance of the outermost regions of a wide-angle lens, the error from lens distortion can be kept below approximately 0.5 percent with a standard lens and 1.5 percent with a wide-angle lens.
Adaptation to sensory-motor reflex perturbations is blind to the source of errors.
Hudson, Todd E; Landy, Michael S
2012-01-06
In the study of visual-motor control, perhaps the most familiar findings involve adaptation to externally imposed movement errors. Theories of visual-motor adaptation based on optimal information processing suppose that the nervous system identifies the sources of errors to effect the most efficient adaptive response. We report two experiments using a novel perturbation based on stimulating a visually induced reflex in the reaching arm. Unlike adaptation to an external force, our method induces a perturbing reflex within the motor system itself, i.e., perturbing forces are self-generated. This novel method allows a test of the theory that error source information is used to generate an optimal adaptive response. If the self-generated source of the visually induced reflex perturbation is identified, the optimal response will be via reflex gain control. If the source is not identified, a compensatory force should be generated to counteract the reflex. Gain control is the optimal response to reflex perturbation, both because energy cost and movement errors are minimized. Energy is conserved because neither reflex-induced nor compensatory forces are generated. Precision is maximized because endpoint variance is proportional to force production. We find evidence against source-identified adaptation in both experiments, suggesting that sensory-motor information processing is not always optimal.
Development of an errorable car-following driver model
NASA Astrophysics Data System (ADS)
Yang, H.-H.; Peng, H.
2010-06-01
An errorable car-following driver model is presented in this paper. An errorable driver model is one that emulates human driver's functions and can generate both nominal (error-free), as well as devious (with error) behaviours. This model was developed for evaluation and design of active safety systems. The car-following data used for developing and validating the model were obtained from a large-scale naturalistic driving database. The stochastic car-following behaviour was first analysed and modelled as a random process. Three error-inducing behaviours were then introduced. First, human perceptual limitation was studied and implemented. Distraction due to non-driving tasks was then identified based on the statistical analysis of the driving data. Finally, time delay of human drivers was estimated through a recursive least-square identification process. By including these three error-inducing behaviours, rear-end collisions with the lead vehicle could occur. The simulated crash rate was found to be similar but somewhat higher than that reported in traffic statistics.
Wave aberrations in rhesus monkeys with vision-induced ametropias
Ramamirtham, Ramkumar; Kee, Chea-su; Hung, Li-Fang; Qiao-Grider, Ying; Huang, Juan; Roorda, Austin; Smith, Earl L.
2007-01-01
The purpose of this study was to investigate the relationship between refractive errors and high-order aberrations in infant rhesus monkeys. Specifically, we compared the monochromatic wave aberrations measured with a Shack-Hartman wavefront sensor between normal monkeys and monkeys with vision-induced refractive errors. Shortly after birth, both normal monkeys and treated monkeys reared with optically induced defocus or form deprivation showed a decrease in the magnitude of high-order aberrations with age. However, the decrease in aberrations was typically smaller in the treated animals. Thus, at the end of the lens-rearing period, higher than normal amounts of aberrations were observed in treated eyes, both hyperopic and myopic eyes and treated eyes that developed astigmatism, but not spherical ametropias. The total RMS wavefront error increased with the degree of spherical refractive error, but was not correlated with the degree of astigmatism. Both myopic and hyperopic treated eyes showed elevated amounts of coma and trefoil and the degree of trefoil increased with the degree of spherical ametropia. Myopic eyes also exhibited a much higher prevalence of positive spherical aberration than normal or treated hyperopic eyes. Following the onset of unrestricted vision, the amount of high-order aberrations decreased in the treated monkeys that also recovered from the experimentally induced refractive errors. Our results demonstrate that high-order aberrations are influenced by visual experience in young primates and that the increase in high-order aberrations in our treated monkeys appears to be an optical byproduct of the vision-induced alterations in ocular growth that underlie changes in refractive error. The results from our study suggest that the higher amounts of wave aberrations observed in ametropic humans are likely to be a consequence, rather than a cause, of abnormal refractive development. PMID:17825347
Xue, Min; Pan, Shilong; Zhao, Yongjiu
2015-02-15
A novel optical vector network analyzer (OVNA) based on optical single-sideband (OSSB) modulation and balanced photodetection is proposed and experimentally demonstrated, which can eliminate the measurement error induced by the high-order sidebands in the OSSB signal. According to the analytical model of the conventional OSSB-based OVNA, if the optical carrier in the OSSB signal is fully suppressed, the measurement result is exactly the high-order-sideband-induced measurement error. By splitting the OSSB signal after the optical device-under-test (ODUT) into two paths, removing the optical carrier in one path, and then detecting the two signals in the two paths using a balanced photodetector (BPD), high-order-sideband-induced measurement error can be ideally eliminated. As a result, accurate responses of the ODUT can be achieved without complex post-signal processing. A proof-of-concept experiment is carried out. The magnitude and phase responses of a fiber Bragg grating (FBG) measured by the proposed OVNA with different modulation indices are superimposed, showing that the high-order-sideband-induced measurement error is effectively removed.
Tarrasch, Ricardo; Berman, Zohar; Friedmann, Naama
2016-01-01
This study explored the effects of a Mindfulness-Based Stress Reduction (MBSR) intervention on reading, attention, and psychological well-being among people with developmental dyslexia and/or attention deficits. Various types of dyslexia exist, characterized by different error types. We examined a question that has not been tested so far: which types of errors (and dyslexias) are affected by MBSR training. To do so, we tested, using an extensive battery of reading tests, whether each participant had dyslexia, and which errors types s/he makes, and then compared the rate of each error type before and after the MBSR workshop. We used a similar approach to attention disorders: we evaluated the participants' sustained, selective, executive, and orienting of attention to assess whether they had attention-disorders, and if so, which functions were impaired. We then evaluated the effect of MBSR on each of the attention functions. Psychological measures including mindfulness, stress, reflection and rumination, lifesatisfaction, depression, anxiety, and sleep-disturbances were also evaluated. Nineteen Hebrew-readers completed a 2-month mindfulness workshop. The results showed that whereas reading errors of letter-migrations within and between words and vowelletter errors did not decrease following the workshop, most participants made fewer reading errors in general following the workshop, with a significant reduction of 19% from their original number of errors. This decrease mainly resulted from a decrease in errors that occur due to reading via the sublexical rather than the lexical route. It seems, therefore, that mindfulness helped reading by keeping the readers on the lexical route. This improvement in reading probably resulted from improved sustained attention: the reduction in sublexical reading was significant for the dyslexic participants who also had attention deficits, and there were significant correlations between reduced reading errors and decreases in impulsivity. Following the meditation workshop, the rate of commission errors decreased, indicating decreased impulsivity, and the variation in RTs in the CPT task decreased, indicating improved sustained attention. Significant improvements were obtained in participants' mindfulness, perceived-stress, rumination, depression, state-anxiety, and sleep-disturbances. Correlations were also obtained between reading improvement and increased mindfulness following the workshop. Thus, whereas mindfulness training did not affect specific types of errors and did not improve dyslexia, it did affect the reading of adults with developmental dyslexia and ADHD, by helping them to stay on the straight path of the lexical route while reading. Thus, the reading improvement induced by mindfulness sheds light on the intricate relation between attention and reading. Mindfulness reduced impulsivity and improved sustained attention, and this, in turn, improved reading of adults with developmental dyslexia and ADHD, by helping them to read via the straight path of the lexical route.
Tarrasch, Ricardo; Berman, Zohar; Friedmann, Naama
2016-01-01
This study explored the effects of a Mindfulness-Based Stress Reduction (MBSR) intervention on reading, attention, and psychological well-being among people with developmental dyslexia and/or attention deficits. Various types of dyslexia exist, characterized by different error types. We examined a question that has not been tested so far: which types of errors (and dyslexias) are affected by MBSR training. To do so, we tested, using an extensive battery of reading tests, whether each participant had dyslexia, and which errors types s/he makes, and then compared the rate of each error type before and after the MBSR workshop. We used a similar approach to attention disorders: we evaluated the participants’ sustained, selective, executive, and orienting of attention to assess whether they had attention-disorders, and if so, which functions were impaired. We then evaluated the effect of MBSR on each of the attention functions. Psychological measures including mindfulness, stress, reflection and rumination, lifesatisfaction, depression, anxiety, and sleep-disturbances were also evaluated. Nineteen Hebrew-readers completed a 2-month mindfulness workshop. The results showed that whereas reading errors of letter-migrations within and between words and vowelletter errors did not decrease following the workshop, most participants made fewer reading errors in general following the workshop, with a significant reduction of 19% from their original number of errors. This decrease mainly resulted from a decrease in errors that occur due to reading via the sublexical rather than the lexical route. It seems, therefore, that mindfulness helped reading by keeping the readers on the lexical route. This improvement in reading probably resulted from improved sustained attention: the reduction in sublexical reading was significant for the dyslexic participants who also had attention deficits, and there were significant correlations between reduced reading errors and decreases in impulsivity. Following the meditation workshop, the rate of commission errors decreased, indicating decreased impulsivity, and the variation in RTs in the CPT task decreased, indicating improved sustained attention. Significant improvements were obtained in participants’ mindfulness, perceived-stress, rumination, depression, state-anxiety, and sleep-disturbances. Correlations were also obtained between reading improvement and increased mindfulness following the workshop. Thus, whereas mindfulness training did not affect specific types of errors and did not improve dyslexia, it did affect the reading of adults with developmental dyslexia and ADHD, by helping them to stay on the straight path of the lexical route while reading. Thus, the reading improvement induced by mindfulness sheds light on the intricate relation between attention and reading. Mindfulness reduced impulsivity and improved sustained attention, and this, in turn, improved reading of adults with developmental dyslexia and ADHD, by helping them to read via the straight path of the lexical route. PMID:27242565
IMRT QA: Selecting gamma criteria based on error detection sensitivity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steers, Jennifer M.; Fraass, Benedick A., E-mail: benedick.fraass@cshs.org
Purpose: The gamma comparison is widely used to evaluate the agreement between measurements and treatment planning system calculations in patient-specific intensity modulated radiation therapy (IMRT) quality assurance (QA). However, recent publications have raised concerns about the lack of sensitivity when employing commonly used gamma criteria. Understanding the actual sensitivity of a wide range of different gamma criteria may allow the definition of more meaningful gamma criteria and tolerance limits in IMRT QA. We present a method that allows the quantitative determination of gamma criteria sensitivity to induced errors which can be applied to any unique combination of device, delivery technique,more » and software utilized in a specific clinic. Methods: A total of 21 DMLC IMRT QA measurements (ArcCHECK®, Sun Nuclear) were compared to QA plan calculations with induced errors. Three scenarios were studied: MU errors, multi-leaf collimator (MLC) errors, and the sensitivity of the gamma comparison to changes in penumbra width. Gamma comparisons were performed between measurements and error-induced calculations using a wide range of gamma criteria, resulting in a total of over 20 000 gamma comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using 36 different gamma criteria. Results: This study demonstrates that systematic errors and case-specific errors can be detected by the error curve analysis. Depending on the location of the error curve peak (e.g., not centered about zero), 3%/3 mm threshold = 10% at 90% pixels passing may miss errors as large as 15% MU errors and ±1 cm random MLC errors for some cases. As the dose threshold parameter was increased for a given %Diff/distance-to-agreement (DTA) setting, error sensitivity was increased by up to a factor of two for select cases. This increased sensitivity with increasing dose threshold was consistent across all studied combinations of %Diff/DTA. Criteria such as 2%/3 mm and 3%/2 mm with a 50% threshold at 90% pixels passing are shown to be more appropriately sensitive without being overly strict. However, a broadening of the penumbra by as much as 5 mm in the beam configuration was difficult to detect with commonly used criteria, as well as with the previously mentioned criteria utilizing a threshold of 50%. Conclusions: We have introduced the error curve method, an analysis technique which allows the quantitative determination of gamma criteria sensitivity to induced errors. The application of the error curve method using DMLC IMRT plans measured on the ArcCHECK® device demonstrated that large errors can potentially be missed in IMRT QA with commonly used gamma criteria (e.g., 3%/3 mm, threshold = 10%, 90% pixels passing). Additionally, increasing the dose threshold value can offer dramatic increases in error sensitivity. This approach may allow the selection of more meaningful gamma criteria for IMRT QA and is straightforward to apply to other combinations of devices and treatment techniques.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menelaou, Evdokia; Paul, Latoya T.; Perera, Surangi N.
Nicotine exposure during embryonic stages of development can affect many neurodevelopmental processes. In the developing zebrafish, exposure to nicotine was reported to cause axonal pathfinding errors in the later born secondary motoneurons (SMNs). These alterations in SMN axon morphology coincided with muscle degeneration at high nicotine concentrations (15–30 μM). Previous work showed that the paralytic mutant zebrafish known as sofa potato exhibited nicotine-induced effects onto SMN axons at these high concentrations but in the absence of any muscle deficits, indicating that pathfinding errors could occur independent of muscle effects. In this study, we used varying concentrations of nicotine at differentmore » developmental windows of exposure to specifically isolate its effects onto subpopulations of motoneuron axons. We found that nicotine exposure can affect SMN axon morphology in a dose-dependent manner. At low concentrations of nicotine, SMN axons exhibited pathfinding errors, in the absence of any nicotine-induced muscle abnormalities. Moreover, the nicotine exposure paradigms used affected the 3 subpopulations of SMN axons differently, but the dorsal projecting SMN axons were primarily affected. We then identified morphologically distinct pathfinding errors that best described the nicotine-induced effects on dorsal projecting SMN axons. To test whether SMN pathfinding was potentially influenced by alterations in the early born primary motoneuron (PMN), we performed dual labeling studies, where both PMN and SMN axons were simultaneously labeled with antibodies. We show that only a subset of the SMN axon pathfinding errors coincided with abnormal PMN axonal targeting in nicotine-exposed zebrafish. We conclude that nicotine exposure can exert differential effects depending on the levels of nicotine and developmental exposure window. - Highlights: • Embryonic nicotine exposure can specifically affect secondary motoneuron axons in a dose-dependent manner. • The nicotine-induced secondary motoneuron axonal pathfinding errors can occur independent of any muscle fiber alterations. • Nicotine exposure primarily affects dorsal projecting secondary motoneurons axons. • Nicotine-induced primary motoneuron axon pathfinding errors can influence secondary motoneuron axon morphology.« less
Shadmehr, Reza; Ohminami, Shinya; Tsutsumi, Ryosuke; Shirota, Yuichiro; Shimizu, Takahiro; Tanaka, Nobuyuki; Terao, Yasuo; Tsuji, Shoji; Ugawa, Yoshikazu; Uchimura, Motoaki; Inoue, Masato; Kitazawa, Shigeru
2015-01-01
Cerebellar damage can profoundly impair human motor adaptation. For example, if reaching movements are perturbed abruptly, cerebellar damage impairs the ability to learn from the perturbation-induced errors. Interestingly, if the perturbation is imposed gradually over many trials, people with cerebellar damage may exhibit improved adaptation. However, this result is controversial, since the differential effects of gradual vs. abrupt protocols have not been observed in all studies. To examine this question, we recruited patients with pure cerebellar ataxia due to cerebellar cortical atrophy (n = 13) and asked them to reach to a target while viewing the scene through wedge prisms. The prisms were computer controlled, making it possible to impose the full perturbation abruptly in one trial, or build up the perturbation gradually over many trials. To control visual feedback, we employed shutter glasses that removed visual feedback during the reach, allowing us to measure trial-by-trial learning from error (termed error-sensitivity), and trial-by-trial decay of motor memory (termed forgetting). We found that the patients benefited significantly from the gradual protocol, improving their performance with respect to the abrupt protocol by exhibiting smaller errors during the exposure block, and producing larger aftereffects during the postexposure block. Trial-by-trial analysis suggested that this improvement was due to increased error-sensitivity in the gradual protocol. Therefore, cerebellar patients exhibited an improved ability to learn from error if they experienced those errors gradually. This improvement coincided with increased error-sensitivity and was present in both groups of subjects, suggesting that control of error-sensitivity may be spared despite cerebellar damage. PMID:26311179
Why do adult dogs (Canis familiaris) commit the A-not-B search error?
Sümegi, Zsófia; Kis, Anna; Miklósi, Ádám; Topál, József
2014-02-01
It has been recently reported that adult domestic dogs, like human infants, tend to commit perseverative search errors; that is, they select the previously rewarded empty location in Piagetian A-not-B search task because of the experimenter's ostensive communicative cues. There is, however, an ongoing debate over whether these findings reveal that dogs can use the human ostensive referential communication as a source of information or the phenomenon can be accounted for by "more simple" explanations like insufficient attention and learning based on local enhancement. In 2 experiments the authors systematically manipulated the type of human cueing (communicative or noncommunicative) adjacent to the A hiding place during both the A and B trials. Results highlight 3 important aspects of the dogs' A-not-B error: (a) search errors are influenced to a certain extent by dogs' motivation to retrieve the toy object; (b) human communicative and noncommunicative signals have different error-inducing effects; and (3) communicative signals presented at the A hiding place during the B trials but not during the A trials play a crucial role in inducing the A-not-B error and it can be induced even without demonstrating repeated hiding events at location A. These findings further confirm the notion that perseverative search error, at least partially, reflects a "ready-to-obey" attitude in the dog rather than insufficient attention and/or working memory.
Radiation-induced refraction artifacts in the optical CT readout of polymer gel dosimeters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Campbell, Warren G.; Jirasek, Andrew, E-mail: jirasek@uvic.ca; Wells, Derek M.
2014-11-01
Purpose: The objective of this work is to demonstrate imaging artifacts that can occur during the optical computed tomography (CT) scanning of polymer gel dosimeters due to radiation-induced refractive index (RI) changes in polyacrylamide gels. Methods: A 1 L cylindrical polyacrylamide gel dosimeter was irradiated with 3 × 3 cm{sup 2} square beams of 6 MV photons. A prototype fan-beam optical CT scanner was used to image the dosimeter. Investigative optical CT scans were performed to examine two types of rayline bending: (i) bending within the plane of the fan-beam and (ii) bending out the plane of the fan-beam. Tomore » address structured errors, an iterative Savitzky–Golay (ISG) filtering routine was designed to filter 2D projections in sinogram space. For comparison, 2D projections were alternatively filtered using an adaptive-mean (AM) filter. Results: In-plane rayline bending was most notably observed in optical CT projections where rays of the fan-beam confronted a sustained dose gradient that was perpendicular to their trajectory but within the fan-beam plane. These errors caused distinct streaking artifacts in image reconstructions due to the refraction of higher intensity rays toward more opaque regions of the dosimeter. Out-of-plane rayline bending was observed in slices of the dosimeter that featured dose gradients perpendicular to the plane of the fan-beam. These errors caused widespread, severe overestimations of dose in image reconstructions due to the higher-than-actual opacity that is perceived by the scanner when light is bent off of the detector array. The ISG filtering routine outperformed AM filtering for both in-plane and out-of-plane rayline errors caused by radiation-induced RI changes. For in-plane rayline errors, streaks in an irradiated region (>7 Gy) were as high as 49% for unfiltered data, 14% for AM, and 6% for ISG. For out-of-plane rayline errors, overestimations of dose in a low-dose region (∼50 cGy) were as high as 13 Gy for unfiltered data, 10 Gy for AM, and 3.1 Gy for ISG. The ISG routine also addressed unrelated artifacts that previously needed to be manually removed in sinogram space. However, the ISG routine blurred reconstructions, causing losses in spatial resolution of ∼5 mm in the plane of the fan-beam and ∼8 mm perpendicular to the fan-beam. Conclusions: This paper reveals a new category of imaging artifacts that can affect the optical CT readout of polyacrylamide gel dosimeters. Investigative scans show that radiation-induced RI changes can cause significant rayline errors when rays confront a prolonged dose gradient that runs perpendicular to their trajectory. In fan-beam optical CT, these errors manifested in two ways: (1) distinct streaking artifacts caused by in-plane rayline bending and (2) severe overestimations of opacity caused by rays bending out of the fan-beam plane and missing the detector array. Although the ISG filtering routine mitigated these errors better than an adaptive-mean filtering routine, it caused unacceptable losses in spatial resolution.« less
Radiation-induced refraction artifacts in the optical CT readout of polymer gel dosimeters.
Campbell, Warren G; Wells, Derek M; Jirasek, Andrew
2014-11-01
The objective of this work is to demonstrate imaging artifacts that can occur during the optical computed tomography (CT) scanning of polymer gel dosimeters due to radiation-induced refractive index (RI) changes in polyacrylamide gels. A 1 L cylindrical polyacrylamide gel dosimeter was irradiated with 3 × 3 cm(2) square beams of 6 MV photons. A prototype fan-beam optical CT scanner was used to image the dosimeter. Investigative optical CT scans were performed to examine two types of rayline bending: (i) bending within the plane of the fan-beam and (ii) bending out the plane of the fan-beam. To address structured errors, an iterative Savitzky-Golay (ISG) filtering routine was designed to filter 2D projections in sinogram space. For comparison, 2D projections were alternatively filtered using an adaptive-mean (AM) filter. In-plane rayline bending was most notably observed in optical CT projections where rays of the fan-beam confronted a sustained dose gradient that was perpendicular to their trajectory but within the fan-beam plane. These errors caused distinct streaking artifacts in image reconstructions due to the refraction of higher intensity rays toward more opaque regions of the dosimeter. Out-of-plane rayline bending was observed in slices of the dosimeter that featured dose gradients perpendicular to the plane of the fan-beam. These errors caused widespread, severe overestimations of dose in image reconstructions due to the higher-than-actual opacity that is perceived by the scanner when light is bent off of the detector array. The ISG filtering routine outperformed AM filtering for both in-plane and out-of-plane rayline errors caused by radiation-induced RI changes. For in-plane rayline errors, streaks in an irradiated region (>7 Gy) were as high as 49% for unfiltered data, 14% for AM, and 6% for ISG. For out-of-plane rayline errors, overestimations of dose in a low-dose region (∼50 cGy) were as high as 13 Gy for unfiltered data, 10 Gy for AM, and 3.1 Gy for ISG. The ISG routine also addressed unrelated artifacts that previously needed to be manually removed in sinogram space. However, the ISG routine blurred reconstructions, causing losses in spatial resolution of ∼5 mm in the plane of the fan-beam and ∼8 mm perpendicular to the fan-beam. This paper reveals a new category of imaging artifacts that can affect the optical CT readout of polyacrylamide gel dosimeters. Investigative scans show that radiation-induced RI changes can cause significant rayline errors when rays confront a prolonged dose gradient that runs perpendicular to their trajectory. In fan-beam optical CT, these errors manifested in two ways: (1) distinct streaking artifacts caused by in-plane rayline bending and (2) severe overestimations of opacity caused by rays bending out of the fan-beam plane and missing the detector array. Although the ISG filtering routine mitigated these errors better than an adaptive-mean filtering routine, it caused unacceptable losses in spatial resolution.
Malinowski, Kathleen; McAvoy, Thomas J.; George, Rohini; Dieterich, Sonja; D’Souza, Warren D.
2013-01-01
Purpose: To determine how best to time respiratory surrogate-based tumor motion model updates by comparing a novel technique based on external measurements alone to three direct measurement methods. Methods: Concurrently measured tumor and respiratory surrogate positions from 166 treatment fractions for lung or pancreas lesions were analyzed. Partial-least-squares regression models of tumor position from marker motion were created from the first six measurements in each dataset. Successive tumor localizations were obtained at a rate of once per minute on average. Model updates were timed according to four methods: never, respiratory surrogate-based (when metrics based on respiratory surrogate measurements exceeded confidence limits), error-based (when localization error ≥3 mm), and always (approximately once per minute). Results: Radial tumor displacement prediction errors (mean ± standard deviation) for the four schema described above were 2.4 ± 1.2, 1.9 ± 0.9, 1.9 ± 0.8, and 1.7 ± 0.8 mm, respectively. The never-update error was significantly larger than errors of the other methods. Mean update counts over 20 min were 0, 4, 9, and 24, respectively. Conclusions: The same improvement in tumor localization accuracy could be achieved through any of the three update methods, but significantly fewer updates were required when the respiratory surrogate method was utilized. This study establishes the feasibility of timing image acquisitions for updating respiratory surrogate models without direct tumor localization. PMID:23822413
Average BER and outage probability of the ground-to-train OWC link in turbulence with rain
NASA Astrophysics Data System (ADS)
Zhang, Yixin; Yang, Yanqiu; Hu, Beibei; Yu, Lin; Hu, Zheng-Da
2017-09-01
The bit-error rate (BER) and outage probability of optical wireless communication (OWC) link for the ground-to-train of the curved track in turbulence with rain is evaluated. Considering the re-modulation effects of raining fluctuation on optical signal modulated by turbulence, we set up the models of average BER and outage probability in the present of pointing errors, based on the double inverse Gaussian (IG) statistical distribution model. The numerical results indicate that, for the same covered track length, the larger curvature radius increases the outage probability and average BER. The performance of the OWC link in turbulence with rain is limited mainly by the rain rate and pointing errors which are induced by the beam wander and train vibration. The effect of the rain rate on the performance of the link is more severe than the atmospheric turbulence, but the fluctuation owing to the atmospheric turbulence affects the laser beam propagation more greatly than the skewness of the rain distribution. Besides, the turbulence-induced beam wander has a more significant impact on the system in heavier rain. We can choose the size of transmitting and receiving apertures and improve the shockproof performance of the tracks to optimize the communication performance of the system.
Magnetic-field sensing with quantum error detection under the effect of energy relaxation
NASA Astrophysics Data System (ADS)
Matsuzaki, Yuichiro; Benjamin, Simon
2017-03-01
A solid state spin is an attractive system with which to realize an ultrasensitive magnetic field sensor. A spin superposition state will acquire a phase induced by the target field, and we can estimate the field strength from this phase. Recent studies have aimed at improving sensitivity through the use of quantum error correction (QEC) to detect and correct any bit-flip errors that may occur during the sensing period. Here we investigate the performance of a two-qubit sensor employing QEC and under the effect of energy relaxation. Surprisingly, we find that the standard QEC technique to detect and recover from an error does not improve the sensitivity compared with the single-qubit sensors. This is a consequence of the fact that the energy relaxation induces both a phase-flip and a bit-flip noise where the former noise cannot be distinguished from the relative phase induced from the target fields. However, we have found that we can improve the sensitivity if we adopt postselection to discard the state when error is detected. Even when quantum error detection is moderately noisy, and allowing for the cost of the postselection technique, we find that this two-qubit system shows an advantage in sensing over a single qubit in the same conditions.
Target Uncertainty Mediates Sensorimotor Error Correction
Vijayakumar, Sethu; Wolpert, Daniel M.
2017-01-01
Human movements are prone to errors that arise from inaccuracies in both our perceptual processing and execution of motor commands. We can reduce such errors by both improving our estimates of the state of the world and through online error correction of the ongoing action. Two prominent frameworks that explain how humans solve these problems are Bayesian estimation and stochastic optimal feedback control. Here we examine the interaction between estimation and control by asking if uncertainty in estimates affects how subjects correct for errors that may arise during the movement. Unbeknownst to participants, we randomly shifted the visual feedback of their finger position as they reached to indicate the center of mass of an object. Even though participants were given ample time to compensate for this perturbation, they only fully corrected for the induced error on trials with low uncertainty about center of mass, with correction only partial in trials involving more uncertainty. The analysis of subjects’ scores revealed that participants corrected for errors just enough to avoid significant decrease in their overall scores, in agreement with the minimal intervention principle of optimal feedback control. We explain this behavior with a term in the loss function that accounts for the additional effort of adjusting one’s response. By suggesting that subjects’ decision uncertainty, as reflected in their posterior distribution, is a major factor in determining how their sensorimotor system responds to error, our findings support theoretical models in which the decision making and control processes are fully integrated. PMID:28129323
Target Uncertainty Mediates Sensorimotor Error Correction.
Acerbi, Luigi; Vijayakumar, Sethu; Wolpert, Daniel M
2017-01-01
Human movements are prone to errors that arise from inaccuracies in both our perceptual processing and execution of motor commands. We can reduce such errors by both improving our estimates of the state of the world and through online error correction of the ongoing action. Two prominent frameworks that explain how humans solve these problems are Bayesian estimation and stochastic optimal feedback control. Here we examine the interaction between estimation and control by asking if uncertainty in estimates affects how subjects correct for errors that may arise during the movement. Unbeknownst to participants, we randomly shifted the visual feedback of their finger position as they reached to indicate the center of mass of an object. Even though participants were given ample time to compensate for this perturbation, they only fully corrected for the induced error on trials with low uncertainty about center of mass, with correction only partial in trials involving more uncertainty. The analysis of subjects' scores revealed that participants corrected for errors just enough to avoid significant decrease in their overall scores, in agreement with the minimal intervention principle of optimal feedback control. We explain this behavior with a term in the loss function that accounts for the additional effort of adjusting one's response. By suggesting that subjects' decision uncertainty, as reflected in their posterior distribution, is a major factor in determining how their sensorimotor system responds to error, our findings support theoretical models in which the decision making and control processes are fully integrated.
Effect of Numerical Error on Gravity Field Estimation for GRACE and Future Gravity Missions
NASA Astrophysics Data System (ADS)
McCullough, Christopher; Bettadpur, Srinivas
2015-04-01
In recent decades, gravity field determination from low Earth orbiting satellites, such as the Gravity Recovery and Climate Experiment (GRACE), has become increasingly more effective due to the incorporation of high accuracy measurement devices. Since instrumentation quality will only increase in the near future and the gravity field determination process is computationally and numerically intensive, numerical error from the use of double precision arithmetic will eventually become a prominent error source. While using double-extended or quadruple precision arithmetic will reduce these errors, the numerical limitations of current orbit determination algorithms and processes must be accurately identified and quantified in order to adequately inform the science data processing techniques of future gravity missions. The most obvious numerical limitation in the orbit determination process is evident in the comparison of measured observables with computed values, derived from mathematical models relating the satellites' numerically integrated state to the observable. Significant error in the computed trajectory will corrupt this comparison and induce error in the least squares solution of the gravitational field. In addition, errors in the numerically computed trajectory propagate into the evaluation of the mathematical measurement model's partial derivatives. These errors amalgamate in turn with numerical error from the computation of the state transition matrix, computed using the variational equations of motion, in the least squares mapping matrix. Finally, the solution of the linearized least squares system, computed using a QR factorization, is also susceptible to numerical error. Certain interesting combinations of each of these numerical errors are examined in the framework of GRACE gravity field determination to analyze and quantify their effects on gravity field recovery.
Driving Performance Under Alcohol in Simulated Representative Driving Tasks
Kenntner-Mabiala, Ramona; Kaussner, Yvonne; Jagiellowicz-Kaufmann, Monika; Hoffmann, Sonja; Krüger, Hans-Peter
2015-01-01
Abstract Comparing drug-induced driving impairments with the effects of benchmark blood alcohol concentrations (BACs) is an approved approach to determine the clinical relevance of findings for traffic safety. The present study aimed to collect alcohol calibration data to validate findings of clinical trials that were derived from a representative test course in a dynamic driving simulator. The driving performance of 24 healthy volunteers under placebo and with 0.05% and 0.08% BACs was measured in a double-blind, randomized, crossover design. Trained investigators assessed the subjects’ driving performance and registered their driving errors. Various driving parameters that were recorded during the simulation were also analyzed. Generally, the participants performed worse on the test course (P < 0.05 for the investigators’ assessment) under the influence of alcohol. Consistent with the relevant literature, lane-keeping performance parameters were sensitive to the investigated BACs. There were significant differences between the alcohol and placebo conditions in most of the parameters analyzed. However, the total number of errors was the only parameter discriminating significantly between all three BAC conditions. In conclusion, data show that the present experimental setup is suitable for future psychopharmacological research. Thereby, for each drug to be investigated, we recommend to assess a profile of various parameters that address different levels of driving. On the basis of this performance profile, the total number of driving errors is recommended as the primary endpoint. However, this overall endpoint should be completed by a specifically sensitive parameter that is chosen depending on the effect known to be induced by the tested drug. PMID:25689289
Dichrometer errors resulting from large signals or improper modulator phasing.
Sutherland, John C
2012-09-01
A single-beam spectrometer equipped with a photoelastic modulator can be configured to measure a number of different parameters useful in characterizing chemical and biochemical materials including natural and magnetic circular dichroism, linear dichroism, natural and magnetic fluorescence-detected circular dichroism, and fluorescence polarization anisotropy as well as total absorption and fluorescence. The derivations of the mathematical expressions used to extract these parameters from ultraviolet, visible, and near-infrared light-induced electronic signals in a dichrometer assume that the dichroic signals are sufficiently small that certain mathematical approximations will not introduce significant errors. This article quantifies errors resulting from these assumptions as a function of the magnitude of the dichroic signals. In the case of linear dichroism, improper modulator programming can result in errors greater than those resulting from the assumption of small signal size, whereas for fluorescence polarization anisotropy, improper modulator phase alone gives incorrect results. Modulator phase can also impact the values of total absorbance recorded simultaneously with linear dichroism and total fluorescence. Copyright © 2012 Wiley Periodicals, Inc., A Wiley Company.
Modeling Inborn Errors of Hepatic Metabolism Using Induced Pluripotent Stem Cells.
Pournasr, Behshad; Duncan, Stephen A
2017-11-01
Inborn errors of hepatic metabolism are because of deficiencies commonly within a single enzyme as a consequence of heritable mutations in the genome. Individually such diseases are rare, but collectively they are common. Advances in genome-wide association studies and DNA sequencing have helped researchers identify the underlying genetic basis of such diseases. Unfortunately, cellular and animal models that accurately recapitulate these inborn errors of hepatic metabolism in the laboratory have been lacking. Recently, investigators have exploited molecular techniques to generate induced pluripotent stem cells from patients' somatic cells. Induced pluripotent stem cells can differentiate into a wide variety of cell types, including hepatocytes, thereby offering an innovative approach to unravel the mechanisms underlying inborn errors of hepatic metabolism. Moreover, such cell models could potentially provide a platform for the discovery of therapeutics. In this mini-review, we present a brief overview of the state-of-the-art in using pluripotent stem cells for such studies. © 2017 American Heart Association, Inc.
Gating of neural error signals during motor learning
Kimpo, Rhea R; Rinaldi, Jacob M; Kim, Christina K; Payne, Hannah L; Raymond, Jennifer L
2014-01-01
Cerebellar climbing fiber activity encodes performance errors during many motor learning tasks, but the role of these error signals in learning has been controversial. We compared two motor learning paradigms that elicited equally robust putative error signals in the same climbing fibers: learned increases and decreases in the gain of the vestibulo-ocular reflex (VOR). During VOR-increase training, climbing fiber activity on one trial predicted changes in cerebellar output on the next trial, and optogenetic activation of climbing fibers to mimic their encoding of performance errors was sufficient to implant a motor memory. In contrast, during VOR-decrease training, there was no trial-by-trial correlation between climbing fiber activity and changes in cerebellar output, and climbing fiber activation did not induce VOR-decrease learning. Our data suggest that the ability of climbing fibers to induce plasticity can be dynamically gated in vivo, even under conditions where climbing fibers are robustly activated by performance errors. DOI: http://dx.doi.org/10.7554/eLife.02076.001 PMID:24755290
Simulating and Detecting Radiation-Induced Errors for Onboard Machine Learning
NASA Technical Reports Server (NTRS)
Wagstaff, Kiri L.; Bornstein, Benjamin; Granat, Robert; Tang, Benyang; Turmon, Michael
2009-01-01
Spacecraft processors and memory are subjected to high radiation doses and therefore employ radiation-hardened components. However, these components are orders of magnitude more expensive than typical desktop components, and they lag years behind in terms of speed and size. We have integrated algorithm-based fault tolerance (ABFT) methods into onboard data analysis algorithms to detect radiation-induced errors, which ultimately may permit the use of spacecraft memory that need not be fully hardened, reducing cost and increasing capability at the same time. We have also developed a lightweight software radiation simulator, BITFLIPS, that permits evaluation of error detection strategies in a controlled fashion, including the specification of the radiation rate and selective exposure of individual data structures. Using BITFLIPS, we evaluated our error detection methods when using a support vector machine to analyze data collected by the Mars Odyssey spacecraft. We found ABFT error detection for matrix multiplication is very successful, while error detection for Gaussian kernel computation still has room for improvement.
Alpha particle-induced soft errors in microelectronic devices. I
NASA Astrophysics Data System (ADS)
Redman, D. J.; Sega, R. M.; Joseph, R.
1980-03-01
The article provides a tutorial review and trend assessment of the problem of alpha particle-induced soft errors in VLSI memories. Attention is given to an analysis of the design evolution of modern ICs, and the characteristics of alpha particles and their origin in IC packaging are reviewed. Finally, the process of an alpha particle penetrating an IC is examined.
Multi-bits error detection and fast recovery in RISC cores
NASA Astrophysics Data System (ADS)
Jing, Wang; Xing, Yang; Yuanfu, Zhao; Weigong, Zhang; Jiao, Shen; Keni, Qiu
2015-11-01
The particles-induced soft errors are a major threat to the reliability of microprocessors. Even worse, multi-bits upsets (MBUs) are ever-increased due to the rapidly shrinking feature size of the IC on a chip. Several architecture-level mechanisms have been proposed to protect microprocessors from soft errors, such as dual and triple modular redundancies (DMR and TMR). However, most of them are inefficient to combat the growing multi-bits errors or cannot well balance the critical paths delay, area and power penalty. This paper proposes a novel architecture, self-recovery dual-pipeline (SRDP), to effectively provide soft error detection and recovery with low cost for general RISC structures. We focus on the following three aspects. First, an advanced DMR pipeline is devised to detect soft error, especially MBU. Second, SEU/MBU errors can be located by enhancing self-checking logic into pipelines stage registers. Third, a recovery scheme is proposed with a recovery cost of 1 or 5 clock cycles. Our evaluation of a prototype implementation exhibits that the SRDP can successfully detect particle-induced soft errors up to 100% and recovery is nearly 95%, the other 5% will inter a specific trap.
Avoidance of APOBEC3B-induced mutation by error-free lesion bypass
Hoopes, James I.; Hughes, Amber L.; Hobson, Lauren A.; Cortez, Luis M.; Brown, Alexander J.
2017-01-01
Abstract APOBEC cytidine deaminases mutate cancer genomes by converting cytidines into uridines within ssDNA during replication. Although uracil DNA glycosylases limit APOBEC-induced mutation, it is unknown if subsequent base excision repair (BER) steps function on replication-associated ssDNA. Hence, we measured APOBEC3B-induced CAN1 mutation frequencies in yeast deficient in BER endonucleases or DNA damage tolerance proteins. Strains lacking Apn1, Apn2, Ntg1, Ntg2 or Rev3 displayed wild-type frequencies of APOBEC3B-induced canavanine resistance (CanR). However, strains without error-free lesion bypass proteins Ubc13, Mms2 and Mph1 displayed respective 4.9-, 2.8- and 7.8-fold higher frequency of APOBEC3B-induced CanR. These results indicate that mutations resulting from APOBEC activity are avoided by deoxyuridine conversion to abasic sites ahead of nascent lagging strand DNA synthesis and subsequent bypass by error-free template switching. We found this mechanism also functions during telomere re-synthesis, but with a diminished requirement for Ubc13. Interestingly, reduction of G to C substitutions in Ubc13-deficient strains uncovered a previously unknown role of Ubc13 in controlling the activity of the translesion synthesis polymerase, Rev1. Our results highlight a novel mechanism for error-free bypass of deoxyuridines generated within ssDNA and suggest that the APOBEC mutation signature observed in cancer genomes may under-represent the genomic damage these enzymes induce. PMID:28334887
Riddell, Nina; Faou, Pierre; Murphy, Melanie; Giummarra, Loretta; Downs, Rachael A.; Rajapaksha, Harinda
2017-01-01
Purpose Microarray and RNA sequencing studies in the chick model of early optically induced refractive error have implicated thousands of genes, many of which have also been linked to ocular pathologies in humans, including age-related macular degeneration (AMD), choroidal neovascularization, glaucoma, and cataract. These findings highlight the potential relevance of the chick model to understanding both refractive error development and the progression to secondary pathological complications. The present study aimed to determine whether proteomic responses to early optical defocus in the chick share similarities with these transcriptome-level changes, particularly in terms of dysregulation of pathology-related molecular processes. Methods Chicks were assigned to a lens condition (monocular +10 D [diopters] to induce hyperopia, −10 D to induce myopia, or no lens) on post-hatch day 5. Biometric measures were collected following a further 6 h and 48 h of rearing. The retina/RPE was then removed and prepared for liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) on an LTQ-Orbitrap Elite. Raw data were processed using MaxQuant, and differentially abundant proteins were identified using moderated t tests (fold change ≥1.5, Benjamini-Hochberg adjusted p<0.05). These differentially abundant proteins were compared with the genes and proteins implicated in previous exploratory transcriptome and proteomic studies of refractive error, as well as the genes and proteins linked to the ocular pathologies listed above for which myopia or hyperopia are risk factors. Finally, gene set enrichment analysis (GSEA) was used to assess whether gene sets from the Human Phenotype Ontology database were enriched in the lens groups relative to the no lens groups, and at the top or bottom of the protein data ranked by Spearman’s correlation with refraction at 6 and 48 h. Results Refractive errors of −2.63 D ± 0.31 D (mean ± standard error, SE) and 3.90 D ± 0.37 D were evident in the negative and positive lens groups, respectively, at 6 h. By 48 h, refractive compensation to both lens types was almost complete (negative lens −9.70 D ± 0.41 D, positive lens 7.70 D ± 0.44 D). More than 140 differentially abundant proteins were identified in each lens group relative to the no lens controls at both time points. No proteins were differentially abundant between the negative and positive lens groups at 6 h, and 13 were differentially abundant at 48 h. As there was substantial overlap in the proteins implicated across the six comparisons, a total of 390 differentially abundant proteins were identified. Sixty-five of these 390 proteins had previously been implicated in transcriptome studies of refractive error animal models, and 42 had previously been associated with AMD, choroidal neovascularization, glaucoma, and/or cataract in humans. The overlap of differentially abundant proteins with AMD-associated genes and proteins was statistically significant for all conditions (Benjamini-Hochberg adjusted p<0.05), with over-representation analysis implicating ontologies related to oxidative stress, cholesterol homeostasis, and melanin biosynthesis. GSEA identified significant enrichment of genes associated with abnormal electroretinogram, photophobia, and nyctalopia phenotypes in the proteins negatively correlated with ocular refraction across the lens groups at 6 h. The implicated proteins were primarily linked to photoreceptor dystrophies and mitochondrial disorders in humans. Conclusions Optical defocus in the chicks induces rapid changes in the abundance of many proteins in the retina/RPE that have previously been linked to inherited and age-related ocular pathologies in humans. Similar changes have been identified in a meta-analysis of chick refractive error transcriptome studies, highlighting the chick as a model for the study of optically induced stress with possible relevance to understanding the development of a range of pathological states in humans. PMID:29259393
Embedded Model Error Representation and Propagation in Climate Models
NASA Astrophysics Data System (ADS)
Sargsyan, K.; Ricciuto, D. M.; Safta, C.; Thornton, P. E.
2017-12-01
Over the last decade, parametric uncertainty quantification (UQ) methods have reached a level of maturity, while the same can not be said about representation and quantification of structural or model errors. Lack of characterization of model errors, induced by physical assumptions, phenomenological parameterizations or constitutive laws, is a major handicap in predictive science. In particular, e.g. in climate models, significant computational resources are dedicated to model calibration without gaining improvement in predictive skill. Neglecting model errors during calibration/tuning will lead to overconfident and biased model parameters. At the same time, the most advanced methods accounting for model error merely correct output biases, augmenting model outputs with statistical error terms that can potentially violate physical laws, or make the calibrated model ineffective for extrapolative scenarios. This work will overview a principled path for representing and quantifying model errors, as well as propagating them together with the rest of the predictive uncertainty budget, including data noise, parametric uncertainties and surrogate-related errors. Namely, the model error terms will be embedded in select model components rather than as external corrections. Such embedding ensures consistency with physical constraints on model predictions, and renders calibrated model predictions meaningful and robust with respect to model errors. Besides, in the presence of observational data, the approach can effectively differentiate model structural deficiencies from those of data acquisition. The methodology is implemented in UQ Toolkit (www.sandia.gov/uqtoolkit), relying on a host of available forward and inverse UQ tools. We will demonstrate the application of the technique on few application of interest, including ACME Land Model calibration via a wide range of measurements obtained at select sites.
Errors in Aviation Decision Making: Bad Decisions or Bad Luck?
NASA Technical Reports Server (NTRS)
Orasanu, Judith; Martin, Lynne; Davison, Jeannie; Null, Cynthia H. (Technical Monitor)
1998-01-01
Despite efforts to design systems and procedures to support 'correct' and safe operations in aviation, errors in human judgment still occur and contribute to accidents. In this paper we examine how an NDM (naturalistic decision making) approach might help us to understand the role of decision processes in negative outcomes. Our strategy was to examine a collection of identified decision errors through the lens of an aviation decision process model and to search for common patterns. The second, and more difficult, task was to determine what might account for those patterns. The corpus we analyzed consisted of tactical decision errors identified by the NTSB (National Transportation Safety Board) from a set of accidents in which crew behavior contributed to the accident. A common pattern emerged: about three quarters of the errors represented plan-continuation errors, that is, a decision to continue with the original plan despite cues that suggested changing the course of action. Features in the context that might contribute to these errors were identified: (a) ambiguous dynamic conditions and (b) organizational and socially-induced goal conflicts. We hypothesize that 'errors' are mediated by underestimation of risk and failure to analyze the potential consequences of continuing with the initial plan. Stressors may further contribute to these effects. Suggestions for improving performance in these error-inducing contexts are discussed.
NASA Astrophysics Data System (ADS)
Varotsos, G. K.; Nistazakis, H. E.; Petkovic, M. I.; Djordjevic, G. T.; Tombras, G. S.
2017-11-01
Over the last years terrestrial free-space optical (FSO) communication systems have demonstrated an increasing scientific and commercial interest in response to the growing demands for ultra high bandwidth, cost-effective and secure wireless data transmissions. However, due the signal propagation through the atmosphere, the performance of such links depends strongly on the atmospheric conditions such as weather phenomena and turbulence effect. Additionally, their operation is affected significantly by the pointing errors effect which is caused by the misalignment of the optical beam between the transmitter and the receiver. In order to address this significant performance degradation, several statistical models have been proposed, while particular attention has been also given to diversity methods. Here, the turbulence-induced fading of the received optical signal irradiance is studied through the M (alaga) distribution, which is an accurate model suitable for weak to strong turbulence conditions and unifies most of the well-known, previously emerged models. Thus, taking into account the atmospheric turbulence conditions along with the pointing errors effect with nonzero boresight and the modulation technique that is used, we derive mathematical expressions for the estimation of the average bit error rate performance for SIMO FSO links. Finally, proper numerical results are given to verify our derived expressions and Monte Carlo simulations are also provided to further validate the accuracy of the analysis proposed and the obtained mathematical expressions.
NASA Technical Reports Server (NTRS)
Mahesh, Ashwin; Spinhirne, James D.; Duda, David P.; Eloranta, Edwin W.; Starr, David O'C (Technical Monitor)
2001-01-01
The altimetry bias in GLAS (Geoscience Laser Altimeter System) or other laser altimeters resulting from atmospheric multiple scattering is studied in relationship to current knowledge of cloud properties over the Antarctic Plateau. Estimates of seasonal and interannual changes in the bias are presented. Results show the bias in altitude from multiple scattering in clouds would be a significant error source without correction. The selective use of low optical depth clouds or cloudfree observations, as well as improved analysis of the return pulse such as by the Gaussian method used here, are necessary to minimize the surface altitude errors. The magnitude of the bias is affected by variations in cloud height, cloud effective particle size and optical depth. Interannual variations in these properties as well as in cloud cover fraction could lead to significant year-to-year variations in the altitude bias. Although cloud-free observations reduce biases in surface elevation measurements from space, over Antarctica these may often include near-surface blowing snow, also a source of scattering-induced delay. With careful selection and analysis of data, laser altimetry specifications can be met.
Methods to achieve accurate projection of regional and global raster databases
Usery, E. Lynn; Seong, Jeong Chang; Steinwand, Dan
2002-01-01
Modeling regional and global activities of climatic and human-induced change requires accurate geographic data from which we can develop mathematical and statistical tabulations of attributes and properties of the environment. Many of these models depend on data formatted as raster cells or matrices of pixel values. Recently, it has been demonstrated that regional and global raster datasets are subject to significant error from mathematical projection and that these errors are of such magnitude that model results may be jeopardized (Steinwand, et al., 1995; Yang, et al., 1996; Usery and Seong, 2001; Seong and Usery, 2001). There is a need to develop methods of projection that maintain the accuracy of these datasets to support regional and global analyses and modeling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahn, Charlene; Wiseman, Howard; Jacobs, Kurt
2004-08-01
It was shown by Ahn, Wiseman, and Milburn [Phys. Rev. A 67, 052310 (2003)] that feedback control could be used as a quantum error correction process for errors induced by weak continuous measurement, given one perfectly measured error channel per qubit. Here we point out that this method can be easily extended to an arbitrary number of error channels per qubit. We show that the feedback protocols generated by our method encode n-2 logical qubits in n physical qubits, thus requiring just one more physical qubit than in the previous case.
Observer detection of image degradation caused by irreversible data compression processes
NASA Astrophysics Data System (ADS)
Chen, Ji; Flynn, Michael J.; Gross, Barry; Spizarny, David
1991-05-01
Irreversible data compression methods have been proposed to reduce the data storage and communication requirements of digital imaging systems. In general, the error produced by compression increases as an algorithm''s compression ratio is increased. We have studied the relationship between compression ratios and the detection of induced error using radiologic observers. The nature of the errors was characterized by calculating the power spectrum of the difference image. In contrast with studies designed to test whether detected errors alter diagnostic decisions, this study was designed to test whether observers could detect the induced error. A paired-film observer study was designed to test whether induced errors were detected. The study was conducted with chest radiographs selected and ranked for subtle evidence of interstitial disease, pulmonary nodules, or pneumothoraces. Images were digitized at 86 microns (4K X 5K) and 2K X 2K regions were extracted. A full-frame discrete cosine transform method was used to compress images at ratios varying between 6:1 and 60:1. The decompressed images were reprinted next to the original images in a randomized order with a laser film printer. The use of a film digitizer and a film printer which can reproduce all of the contrast and detail in the original radiograph makes the results of this study insensitive to instrument performance and primarily dependent on radiographic image quality. The results of this study define conditions for which errors associated with irreversible compression cannot be detected by radiologic observers. The results indicate that an observer can detect the errors introduced by this compression algorithm for compression ratios of 10:1 (1.2 bits/pixel) or higher.
McClintock, Brett T.; Bailey, Larissa L.; Pollock, Kenneth H.; Simons, Theodore R.
2010-01-01
The recent surge in the development and application of species occurrence models has been associated with an acknowledgment among ecologists that species are detected imperfectly due to observation error. Standard models now allow unbiased estimation of occupancy probability when false negative detections occur, but this is conditional on no false positive detections and sufficient incorporation of explanatory variables for the false negative detection process. These assumptions are likely reasonable in many circumstances, but there is mounting evidence that false positive errors and detection probability heterogeneity may be much more prevalent in studies relying on auditory cues for species detection (e.g., songbird or calling amphibian surveys). We used field survey data from a simulated calling anuran system of known occupancy state to investigate the biases induced by these errors in dynamic models of species occurrence. Despite the participation of expert observers in simplified field conditions, both false positive errors and site detection probability heterogeneity were extensive for most species in the survey. We found that even low levels of false positive errors, constituting as little as 1% of all detections, can cause severe overestimation of site occupancy, colonization, and local extinction probabilities. Further, unmodeled detection probability heterogeneity induced substantial underestimation of occupancy and overestimation of colonization and local extinction probabilities. Completely spurious relationships between species occurrence and explanatory variables were also found. Such misleading inferences would likely have deleterious implications for conservation and management programs. We contend that all forms of observation error, including false positive errors and heterogeneous detection probabilities, must be incorporated into the estimation framework to facilitate reliable inferences about occupancy and its associated vital rate parameters.
Borycki, E M; Kushniruk, A W; Bellwood, P; Brender, J
2012-01-01
The objective of this paper is to examine the extent, range and scope to which frameworks, models and theories dealing with technology-induced error have arisen in the biomedical and life sciences literature as indexed by Medline®. To better understand the state of work in the area of technology-induced error involving frameworks, models and theories, the authors conducted a search of Medline® using selected key words identified from seminal articles in this research area. Articles were reviewed and those pertaining to frameworks, models or theories dealing with technology-induced error were further reviewed by two researchers. All articles from Medline® from its inception to April of 2011 were searched using the above outlined strategy. 239 citations were returned. Each of the abstracts for the 239 citations were reviewed by two researchers. Eleven articles met the criteria based on abstract review. These 11 articles were downloaded for further in-depth review. The majority of the articles obtained describe frameworks and models with reference to theories developed in other literatures outside of healthcare. The papers were grouped into several areas. It was found that articles drew mainly from three literatures: 1) the human factors literature (including human-computer interaction and cognition), 2) the organizational behavior/sociotechnical literature, and 3) the software engineering literature. A variety of frameworks and models were found in the biomedical and life sciences literatures. These frameworks and models drew upon and extended frameworks, models and theoretical perspectives that have emerged in other literatures. These frameworks and models are informing an emerging line of research in health and biomedical informatics involving technology-induced errors in healthcare.
Prediction Accuracy of Error Rates for MPTB Space Experiment
NASA Technical Reports Server (NTRS)
Buchner, S. P.; Campbell, A. B.; Davis, D.; McMorrow, D.; Petersen, E. L.; Stassinopoulos, E. G.; Ritter, J. C.
1998-01-01
This paper addresses the accuracy of radiation-induced upset-rate predictions in space using the results of ground-based measurements together with standard environmental and device models. The study is focused on two part types - 16 Mb NEC DRAM's (UPD4216) and 1 Kb SRAM's (AMD93L422) - both of which are currently in space on board the Microelectronics and Photonics Test Bed (MPTB). To date, ground-based measurements of proton-induced single event upset (SEM cross sections as a function of energy have been obtained and combined with models of the proton environment to predict proton-induced error rates in space. The role played by uncertainties in the environmental models will be determined by comparing the modeled radiation environment with the actual environment measured aboard MPTB. Heavy-ion induced upsets have also been obtained from MPTB and will be compared with the "predicted" error rate following ground testing that will be done in the near future. These results should help identify sources of uncertainty in predictions of SEU rates in space.
NASA Technical Reports Server (NTRS)
Carreno, Victor A.; Choi, G.; Iyer, R. K.
1990-01-01
A simulation study is described which predicts the susceptibility of an advanced control system to electrical transients resulting in logic errors, latched errors, error propagation, and digital upset. The system is based on a custom-designed microprocessor and it incorporates fault-tolerant techniques. The system under test and the method to perform the transient injection experiment are described. Results for 2100 transient injections are analyzed and classified according to charge level, type of error, and location of injection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, Elizabeth S.; Prosnitz, Robert G.; Yu Xiaoli
2006-11-15
Purpose: The aim of this study was to assess the impact of patient-specific factors, left ventricle (LV) volume, and treatment set-up errors on the rate of perfusion defects 6 to 60 months post-radiation therapy (RT) in patients receiving tangential RT for left-sided breast cancer. Methods and Materials: Between 1998 and 2005, a total of 153 patients were enrolled onto an institutional review board-approved prospective study and had pre- and serial post-RT (6-60 months) cardiac perfusion scans to assess for perfusion defects. Of the patients, 108 had normal pre-RT perfusion scans and available follow-up data. The impact of patient-specific factors onmore » the rate of perfusion defects was assessed at various time points using univariate and multivariate analysis. The impact of set-up errors on the rate of perfusion defects was also analyzed using a one-tailed Fisher's Exact test. Results: Consistent with our prior results, the volume of LV in the RT field was the most significant predictor of perfusion defects on both univariate (p = 0.0005 to 0.0058) and multivariate analysis (p = 0.0026 to 0.0029). Body mass index (BMI) was the only significant patient-specific factor on both univariate (p = 0.0005 to 0.022) and multivariate analysis (p = 0.0091 to 0.05). In patients with very small volumes of LV in the planned RT fields, the rate of perfusion defects was significantly higher when the fields set-up 'too deep' (83% vs. 30%, p = 0.059). The frequency of deep set-up errors was significantly higher among patients with BMI {>=}25 kg/m{sup 2} compared with patients of normal weight (47% vs. 28%, p = 0.068). Conclusions: BMI {>=}25 kg/m{sup 2} may be a significant risk factor for cardiac toxicity after RT for left-sided breast cancer, possibly because of more frequent deep set-up errors resulting in the inclusion of additional heart in the RT fields. Further study is necessary to better understand the impact of patient-specific factors and set-up errors on the development of RT-induced perfusion defects.« less
Buzzell, George A; Troller-Renfree, Sonya V; Barker, Tyson V; Bowman, Lindsay C; Chronis-Tuscano, Andrea; Henderson, Heather A; Kagan, Jerome; Pine, Daniel S; Fox, Nathan A
2017-12-01
Behavioral inhibition (BI) is a temperament identified in early childhood that is a risk factor for later social anxiety. However, mechanisms underlying the development of social anxiety remain unclear. To better understand the emergence of social anxiety, longitudinal studies investigating changes at behavioral neural levels are needed. BI was assessed in the laboratory at 2 and 3 years of age (N = 268). Children returned at 12 years, and an electroencephalogram was recorded while children performed a flanker task under 2 conditions: once while believing they were being observed by peers and once while not being observed. This methodology isolated changes in error monitoring (error-related negativity) and behavior (post-error reaction time slowing) as a function of social context. At 12 years, current social anxiety symptoms and lifetime diagnoses of social anxiety were obtained. Childhood BI prospectively predicted social-specific error-related negativity increases and social anxiety symptoms in adolescence; these symptoms directly related to clinical diagnoses. Serial mediation analysis showed that social error-related negativity changes explained relations between BI and social anxiety symptoms (n = 107) and diagnosis (n = 92), but only insofar as social context also led to increased post-error reaction time slowing (a measure of error preoccupation); this model was not significantly related to generalized anxiety. Results extend prior work on socially induced changes in error monitoring and error preoccupation. These measures could index a neurobehavioral mechanism linking BI to adolescent social anxiety symptoms and diagnosis. This mechanism could relate more strongly to social than to generalized anxiety in the peri-adolescent period. Copyright © 2017 American Academy of Child and Adolescent Psychiatry. All rights reserved.
Impact of time-of-flight PET on quantification errors in MR imaging-based attenuation correction.
Mehranian, Abolfazl; Zaidi, Habib
2015-04-01
Time-of-flight (TOF) PET/MR imaging is an emerging imaging technology with great capabilities offered by TOF to improve image quality and lesion detectability. We assessed, for the first time, the impact of TOF image reconstruction on PET quantification errors induced by MR imaging-based attenuation correction (MRAC) using simulation and clinical PET/CT studies. Standard 4-class attenuation maps were derived by segmentation of CT images of 27 patients undergoing PET/CT examinations into background air, lung, soft-tissue, and fat tissue classes, followed by the assignment of predefined attenuation coefficients to each class. For each patient, 4 PET images were reconstructed: non-TOF and TOF both corrected for attenuation using reference CT-based attenuation correction and the resulting 4-class MRAC maps. The relative errors between non-TOF and TOF MRAC reconstructions were compared with their reference CT-based attenuation correction reconstructions. The bias was locally and globally evaluated using volumes of interest (VOIs) defined on lesions and normal tissues and CT-derived tissue classes containing all voxels in a given tissue, respectively. The impact of TOF on reducing the errors induced by metal-susceptibility and respiratory-phase mismatch artifacts was also evaluated using clinical and simulation studies. Our results show that TOF PET can remarkably reduce attenuation correction artifacts and quantification errors in the lungs and bone tissues. Using classwise analysis, it was found that the non-TOF MRAC method results in an error of -3.4% ± 11.5% in the lungs and -21.8% ± 2.9% in bones, whereas its TOF counterpart reduced the errors to -2.9% ± 7.1% and -15.3% ± 2.3%, respectively. The VOI-based analysis revealed that the non-TOF and TOF methods resulted in an average overestimation of 7.5% and 3.9% in or near lung lesions (n = 23) and underestimation of less than 5% for soft tissue and in or near bone lesions (n = 91). Simulation results showed that as TOF resolution improves, artifacts and quantification errors are substantially reduced. TOF PET substantially reduces artifacts and improves significantly the quantitative accuracy of standard MRAC methods. Therefore, MRAC should be less of a concern on future TOF PET/MR scanners with improved timing resolution. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Intrinsic errors in transporting a single-spin qubit through a double quantum dot
NASA Astrophysics Data System (ADS)
Li, Xiao; Barnes, Edwin; Kestner, J. P.; Das Sarma, S.
2017-07-01
Coherent spatial transport or shuttling of a single electron spin through semiconductor nanostructures is an important ingredient in many spintronic and quantum computing applications. In this work we analyze the possible errors in solid-state quantum computation due to leakage in transporting a single-spin qubit through a semiconductor double quantum dot. In particular, we consider three possible sources of leakage errors associated with such transport: finite ramping times, spin-dependent tunneling rates between quantum dots induced by finite spin-orbit couplings, and the presence of multiple valley states. In each case we present quantitative estimates of the leakage errors, and discuss how they can be minimized. The emphasis of this work is on how to deal with the errors intrinsic to the ideal semiconductor structure, such as leakage due to spin-orbit couplings, rather than on errors due to defects or noise sources. In particular, we show that in order to minimize leakage errors induced by spin-dependent tunnelings, it is necessary to apply pulses to perform certain carefully designed spin rotations. We further develop a formalism that allows one to systematically derive constraints on the pulse shapes and present a few examples to highlight the advantage of such an approach.
Smartphone virtual reality to increase clinical balance assessment responsiveness.
Rausch, Matthew; Simon, Janet E; Starkey, Chad; Grooms, Dustin R
2018-05-22
To determine if a low cost smartphone based, clinically applicable virtual reality (VR) modification to the standard Balance Error Scoring System (BESS) can challenge postural stability beyond the traditional BESS. Cross-sectional study. University research laboratory. 28 adults (mean age 23.36 ± 2.38 years, mean height 1.74 m ± 0.13, mean weight 77.95 kg ± 16.63). BESS postural control errors and center of pressure (CoP) velocity were recorded during the BESS test and a VR modified BESS (VR-BESS). The VR-BESS used a headset and phone to display a rollercoaster ride to induce a visual and vestibular challenge to postural stability. The VR-BESS significantly increased total errors (20.93 vs. 11.42, p < 0.05) and CoP velocity summed across all stances and surfaces (52.96 cm/s vs. 37.73 cm/s, p < 0.05) beyond the traditional BESS. The VR-BESS provides a standardized, and effective way to increase postural stability challenge in the clinical setting. The VR-BESS can use any smartphone technology to induce postural stability deficits that may otherwise normalize with traditional testing. Thus, providing a unique relatively inexpensive and simple to operate clinical assessment tool and∖or training stimulus. Copyright © 2018 Elsevier Ltd. All rights reserved.
Absence of Mutagenic Activity of Hycanthone in Serratia marcescens,
1986-05-29
repair system but is enhanced by the plasmid pKMl01, which mediates the inducible error-prone repair system. Hycanthone, like proflavin , .1...enhanced by the plasmid pKM10, which mediates the inducible error-prone repair system. Hycanthone, like proflavin , intercalates between the stacked bases...Roth (1974) lave suggested that proflavin , which has a planar triple ring structure similar to hycanthone, interacts with DNA, which upon replication
A Unified Approach to Measurement Error and Missing Data: Overview and Applications
ERIC Educational Resources Information Center
Blackwell, Matthew; Honaker, James; King, Gary
2017-01-01
Although social scientists devote considerable effort to mitigating measurement error during data collection, they often ignore the issue during data analysis. And although many statistical methods have been proposed for reducing measurement error-induced biases, few have been widely used because of implausible assumptions, high levels of model…
Results from a Sting Whip Correction Verification Test at the Langley 16-Foot Transonic Tunnel
NASA Technical Reports Server (NTRS)
Crawford, B. L.; Finley, T. D.
2002-01-01
In recent years, great strides have been made toward correcting the largest error in inertial Angle of Attack (AoA) measurements in wind tunnel models. This error source is commonly referred to as 'sting whip' and is caused by aerodynamically induced forces imparting dynamics on sting-mounted models. These aerodynamic forces cause the model to whip through an arc section in the pitch and/or yaw planes, thus generating a centrifugal acceleration and creating a bias error in the AoA measurement. It has been shown that, under certain conditions, this induced AoA error can be greater than one third of a degree. An error of this magnitude far exceeds the target AoA goal of 0.01 deg established at NASA Langley Research Center (LaRC) and elsewhere. New sting whip correction techniques being developed at LaRC are able to measure and reduce this sting whip error by an order of magnitude. With this increase of accuracy, the 0.01 deg AoA target is achievable under all but the most severe conditions.
Ali, Mohamed A; Kobashi, Hidenaga; Kamiya, Kazutaka; Igarashi, Akihito; Miyake, Toshiyuki; Elewa, Mohamed Ehab M; Komatsu, Mari; Shimizu, Kimiya
2014-12-01
To compare postoperative astigmatic correction between femtosecond lenticule extraction (FLEx) and wavefront-guided LASIK in eyes with myopic astigmatism. Fifty-eight eyes of 41 patients undergoing FLEx and 49 eyes of 29 patients undergoing wavefront-guided LASIK to correct myopic astigmatism were examined. Visual acuity, cylindrical refraction, predictability of the astigmatic correction, and astigmatic vector components were compared between groups 6 months after surgery. There was no statistically significant difference in manifest cylindrical refraction (P = .08) or percentage of eyes within ± 0.50 diopter (D) of its refraction (P = .11) between the surgical procedures. The index of success in FLEx was statistically significantly better than that of wavefront-guided LASIK (P = .02), although there was no significant difference between the groups in other indices (eg, surgically induced astigmatism, target-induced astigmatism, astigmatic correction index, angle of error, difference vector, and flattening index). Subgroup analysis showed that FLEx had a better index of success (P = .02) and difference vector (P = .04) than wavefront-guided LASIK in the low cylinder subgroup; the angle of error in FLEx was significantly smaller than that of wavefront-guided LASIK in the moderate cylinder subgroup (P = .03). Both FLEx and wavefront-guided LASIK worked well for the correction of myopic astigmatism by the 6-month follow-up visit. Although FLEx had a better index of success than wavefront-guided LASIK when using vector analysis, it appears equivalent to wavefront-guided LASIK in terms of visual acuity and the correction of astigmatism. Copyright 2014, SLACK Incorporated.
Yadav, Satyndra Kumar; Prakash, Jay; Chouhan, Shikha; Singh, Surya Pratap
2013-06-01
Parkinson's disease (PD) is a neurodegenerative disease which causes rigidity, resting tremor and postural instability. Treatment for this disease is still under investigation. Mucuna pruriens (L.), is a traditional herbal medicine, used in India since 1500 B.C., as a neuroprotective agent. In this present study, we evaluated the therapeutic effects of aqueous extract of M. pruriens (Mp) seed in Parkinsonian mouse model developed by chronic exposure to paraquat (PQ). Results of our study revealed that the nigrostriatal portion of Parkinsonian mouse brain showed significantly increased levels of nitrite, malondialdehyde (MDA) and reduced levels of catalase compared to the control. In the Parkinsonian mice hanging time was decreased, whereas narrow beam walk time and foot printing errors were increased. Treatment with aqueous seed extract of Mp significantly increased the catalase activity and decreased the MDA and nitrite level, compared to untreated Parkinsonian mouse brain. Mp treatment also improved the behavioral abnormalities. It increased hanging time, whereas it decreased narrow beam walk time and foot printing error compared to untreated Parkinsonian mouse brain. Furthermore, we observed a significant reduction in tyrosine hydroxylase (TH) immunoreactivity in the substantia nigra (SN) and striatum region of the brain, after treatment with PQ which was considerably restored by the use of Mp seed extract. Our result suggested that Mp seed extract treatment significantly reduced the PQ induced neurotoxicity as evident by decrease in oxidative damage, physiological abnormalities and immunohistochemical changes in the Parkinsonian mouse. Copyright © 2013 Elsevier Ltd. All rights reserved.
Confirmation bias in human reinforcement learning: Evidence from counterfactual feedback processing
Lefebvre, Germain; Blakemore, Sarah-Jayne
2017-01-01
Previous studies suggest that factual learning, that is, learning from obtained outcomes, is biased, such that participants preferentially take into account positive, as compared to negative, prediction errors. However, whether or not the prediction error valence also affects counterfactual learning, that is, learning from forgone outcomes, is unknown. To address this question, we analysed the performance of two groups of participants on reinforcement learning tasks using a computational model that was adapted to test if prediction error valence influences learning. We carried out two experiments: in the factual learning experiment, participants learned from partial feedback (i.e., the outcome of the chosen option only); in the counterfactual learning experiment, participants learned from complete feedback information (i.e., the outcomes of both the chosen and unchosen option were displayed). In the factual learning experiment, we replicated previous findings of a valence-induced bias, whereby participants learned preferentially from positive, relative to negative, prediction errors. In contrast, for counterfactual learning, we found the opposite valence-induced bias: negative prediction errors were preferentially taken into account, relative to positive ones. When considering valence-induced bias in the context of both factual and counterfactual learning, it appears that people tend to preferentially take into account information that confirms their current choice. PMID:28800597
Gordon, H R; Wang, M
1992-07-20
In the algorithm for the atmospheric correction of coastal zone color scanner (CZCS) imagery, it is assumed that the sea surface is flat. Simulations are carried out to assess the error incurred when the CZCS-type algorithm is applied to a realistic ocean in which the surface is roughened by the wind. In situations where there is no direct Sun glitter (either a large solar zenith angle or the sensor tilted away from the specular image of the Sun), the following conclusions appear justified: (1) the error induced by ignoring the surface roughness is less, similar1 CZCS digital count for wind speeds up to approximately 17 m/s, and therefore can be ignored for this sensor; (2) the roughness-induced error is much more strongly dependent on the wind speed than on the wave shadowing, suggesting that surface effects can be adequately dealt with without precise knowledge of the shadowing; and (3) the error induced by ignoring the Rayleigh-aerosol interaction is usually larger than that caused by ignoring the surface roughness, suggesting that in refining algorithms for future sensors more effort should be placed on dealing with the Rayleigh-aerosol interaction than on the roughness of the sea surface.
Confirmation bias in human reinforcement learning: Evidence from counterfactual feedback processing.
Palminteri, Stefano; Lefebvre, Germain; Kilford, Emma J; Blakemore, Sarah-Jayne
2017-08-01
Previous studies suggest that factual learning, that is, learning from obtained outcomes, is biased, such that participants preferentially take into account positive, as compared to negative, prediction errors. However, whether or not the prediction error valence also affects counterfactual learning, that is, learning from forgone outcomes, is unknown. To address this question, we analysed the performance of two groups of participants on reinforcement learning tasks using a computational model that was adapted to test if prediction error valence influences learning. We carried out two experiments: in the factual learning experiment, participants learned from partial feedback (i.e., the outcome of the chosen option only); in the counterfactual learning experiment, participants learned from complete feedback information (i.e., the outcomes of both the chosen and unchosen option were displayed). In the factual learning experiment, we replicated previous findings of a valence-induced bias, whereby participants learned preferentially from positive, relative to negative, prediction errors. In contrast, for counterfactual learning, we found the opposite valence-induced bias: negative prediction errors were preferentially taken into account, relative to positive ones. When considering valence-induced bias in the context of both factual and counterfactual learning, it appears that people tend to preferentially take into account information that confirms their current choice.
Hardness assurance for proton direct ionization-induced SEEs using a high-energy proton beam
Dodds, Nathaniel Anson; Schwank, James R.; Shaneyfelt, Marty R.; ...
2014-11-06
The low-energy proton energy spectra of all shielded space environments have the same shape. This shape is easily reproduced in the laboratory by degrading a high-energy proton beam, producing a high-fidelity test environment. We use this test environment to dramatically simplify rate prediction for proton direct ionization effects, allowing the work to be done at high-energy proton facilities, on encapsulated parts, without knowledge of the IC design, and with little or no computer simulations required. Proton direct ionization (PDI) is predicted to significantly contribute to the total error rate under the conditions investigated. Scaling effects are discussed using data frommore » 65-nm, 45-nm, and 32-nm SOI SRAMs. These data also show that grazing-angle protons will dominate the PDI-induced error rate due to their higher effective LET, so PDI hardness assurance methods must account for angular effects to be conservative. As a result, we show that this angular dependence can be exploited to quickly assess whether an IC is susceptible to PDI.« less
Quantifying and correcting motion artifacts in MRI
NASA Astrophysics Data System (ADS)
Bones, Philip J.; Maclaren, Julian R.; Millane, Rick P.; Watts, Richard
2006-08-01
Patient motion during magnetic resonance imaging (MRI) can produce significant artifacts in a reconstructed image. Since measurements are made in the spatial frequency domain ('k-space'), rigid-body translational motion results in phase errors in the data samples while rotation causes location errors. A method is presented to detect and correct these errors via a modified sampling strategy, thereby achieving more accurate image reconstruction. The strategy involves sampling vertical and horizontal strips alternately in k-space and employs phase correlation within the overlapping segments to estimate translational motion. An extension, also based on correlation, is employed to estimate rotational motion. Results from simulations with computer-generated phantoms suggest that the algorithm is robust up to realistic noise levels. The work is being extended to physical phantoms. Provided that a reference image is available and the object is of limited extent, it is shown that a measure related to the amount of energy outside the support can be used to objectively compare the severity of motion-induced artifacts.
Neuropsychology of selective attention and magnetic cortical stimulation.
Sabatino, M; Di Nuovo, S; Sardo, P; Abbate, C S; La Grutta, V
1996-01-01
Informed volunteers were asked to perform different neuropsychological tests involving selective attention under control conditions and during transcranial magnetic cortical stimulation. The tests chosen involved the recognition of a specific letter among different letters (verbal test) and the search for three different spatial orientations of an appendage to a square (visuo-spatial test). For each test the total time taken and the error rate were calculated. Results showed that cortical stimulation did not cause a worsening in performance. Moreover, magnetic stimulation of the temporal lobe neither modified completion time in both verbal and visuo-spatial tests nor changed error rate. In contrast, magnetic stimulation of the pre-frontal area induced a significant reduction in the performance time of both the verbal and visuo-spatial tests always without an increase in the number of errors. The experimental findings underline the importance of the pre-frontal area in performing tasks requiring a high level of controlled attention and suggest the need to adopt an interdisciplinary approach towards the study of neurone/mind interface mechanisms.
Comment on "falsification of the Atmospheric CO2 Greenhouse Effects Within the Frame of Physics"
NASA Astrophysics Data System (ADS)
Halpern, Joshua B.; Colose, Christopher M.; Ho-Stuart, Chris; Shore, Joel D.; Smith, Arthur P.; Zimmermann, Jörg
In this journal, Gerhard Gerlich and Ralf D. Tscheuschner claim to have falsified the existence of an atmospheric greenhouse effect.1 Here, we show that their methods, logic, and conclusions are in error. Their most significant errors include trying to apply the Clausius statement of the Second Law of Thermodynamics to only one side of a heat transfer process rather than the entire process, and systematically ignoring most non-radiative heat flows applicable to the Earth's surface and atmosphere. They claim that radiative heat transfer from a colder atmosphere to a warmer surface is forbidden, ignoring the larger transfer in the other direction which makes the complete process allowed. Further, by ignoring heat capacity and non-radiative heat flows, they claim that radiative balance requires that the surface cool by 100 K or more at night, an obvious absurdity induced by an unphysical assumption. This comment concentrates on these two major points, while also taking note of some of Gerlich and Tscheuschner's other errors and misunderstandings.
Ronchi, Roberta; Revol, Patrice; Katayama, Masahiro; Rossetti, Yves; Farnè, Alessandro
2011-01-01
During the procedure of prism adaptation, subjects execute pointing movements to visual targets under a lateral optical displacement: As consequence of the discrepancy between visual and proprioceptive inputs, their visuo-motor activity is characterized by pointing errors. The perception of such final errors triggers error-correction processes that eventually result into sensori-motor compensation, opposite to the prismatic displacement (i.e., after-effects). Here we tested whether the mere observation of erroneous pointing movements, similar to those executed during prism adaptation, is sufficient to produce adaptation-like after-effects. Neurotypical participants observed, from a first-person perspective, the examiner's arm making incorrect pointing movements that systematically overshot visual targets location to the right, thus simulating a rightward optical deviation. Three classical after-effect measures (proprioceptive, visual and visual-proprioceptive shift) were recorded before and after first-person's perspective observation of pointing errors. Results showed that mere visual exposure to an arm that systematically points on the right-side of a target (i.e., without error correction) produces a leftward after-effect, which mostly affects the observer's proprioceptive estimation of her body midline. In addition, being exposed to such a constant visual error induced in the observer the illusion “to feel” the seen movement. These findings indicate that it is possible to elicit sensori-motor after-effects by mere observation of movement errors. PMID:21731649
Nearwork-induced transient myopia in preadolescent Hong Kong Chinese.
Wolffsohn, James Stuart; Gilmartin, Bernard; Li, Roger Wing-hong; Edwards, Marion Hastings; Chat, Sandy Wing-shan; Lew, John Kwok-fai; Yu, Bibianna Sin-ying
2003-05-01
To compare the magnitude and time course of nearwork-induced transient myopia (NITM) in preadolescent Hong Kong Chinese myopes and emmetropes. Forty-five Hong Kong Chinese children, 35 myopes and 10 emmetropes aged 6 to 12 years (median, 7.5), monocularly viewed a letter target through a Badal lens for 5 minutes at either 5.00- or 2.50-D accommodative demand, followed by 3 minutes of viewing the equivalent target at optical infinity. Accommodative responses were measured continuously with a modified, infrared, objective open-field autorefractor. Accommodative responses were also measured for a countercondition: viewing of a letter target for 5 minutes at optical infinity, followed by 3 minutes of viewing the target at a 5.00-D accommodative demand. The results were compared with tonic accommodation and both subject and family history of refractive error. Retinal-blur-driven NITM was significantly greater in Hong Kong Chinese children with myopic vision than in the emmetropes after both near tasks, but showed no significant dose effect. The NITM was still evident 3 minutes after viewing the 5.00-D near task for 5 minutes. The magnitude of NITM correlated with the accommodative drift after viewing a distant target for more than 4 minutes, but was unrelated to the subjects' or family history of refractive error. In a preadolescent ethnic population with known predisposition to myopia, there is a significant posttask blur-driven accommodative NITM, which is sustained for longer than has previously been found in white adults.
Fraser, Sarah A; Elliott, Valerie; de Bruin, Eling D; Bherer, Louis; Dumoulin, Chantal
2014-06-01
Many women over 65 years of age suffer from mixed urinary incontinence (MUI) and executive function (EF) deficits. Both incontinence and EF declines increase fall risk. The current study assessed EF and dual-task gait after a multicomponent intervention that combined pelvic floor muscle (PFM) training and videogame dancing (VGD). Baseline (Pre1), pretraining (Pre2), and post-training (Post) neuropsychological and dual-task gait assessments were completed by 23 women (mean age, 70.4 years) with MUI. During the dual-task, participants walked and performed an auditory n-back task. From Pre2 to Post, all women completed 12 weeks of combined PFM and VGD training. After training (Pre2 to Post), the number of errors in the Inhibition/Switch Stroop condition decreased significantly, the Trail Making Test difference score improved marginally, and the number of n-back errors during dual-task gait significantly decreased. A subgroup analysis based on continence improvements (pad test) revealed that only those subjects who improved in the pad test had significantly reduced numbers of n-back errors during dual-task gait. The results of this study suggest that a multicomponent intervention can improve EFs and the dual-task gait of older women with MUI. Future research is needed to determine if the training-induced improvements in these factors reduce fall risk.
The effect of the dynamic wet troposphere on VLBI measurements
NASA Technical Reports Server (NTRS)
Treuhaft, R. N.; Lanyi, G. E.
1986-01-01
Calculations using a statistical model of water vapor fluctuations yield the effect of the dynamic wet troposphere on Very Long Baseline Interferometry (VLBI) measurements. The statistical model arises from two primary assumptions: (1) the spatial structure of refractivity fluctuations can be closely approximated by elementary (Kolmogorov) turbulence theory, and (2) temporal fluctuations are caused by spatial patterns which are moved over a site by the wind. The consequences of these assumptions are outlined for the VLBI delay and delay rate observables. For example, wet troposphere induced rms delays for Deep Space Network (DSN) VLBI at 20-deg elevation are about 3 cm of delay per observation, which is smaller, on the average, than other known error sources in the current DSN VLBI data set. At 20-deg elevation for 200-s time intervals, water vapor induces approximately 1.5 x 10 to the minus 13th power s/s in the Allan standard deviation of interferometric delay, which is a measure of the delay rate observable error. In contrast to the delay error, the delay rate measurement error is dominated by water vapor fluctuations. Water vapor induced VLBI parameter errors and correlations are calculated. For the DSN, baseline length parameter errors due to water vapor fluctuations are in the range of 3 to 5 cm. The above physical assumptions also lead to a method for including the water vapor fluctuations in the parameter estimation procedure, which is used to extract baseline and source information from the VLBI observables.
Lee, Norman; Ward, Jessica L; Vélez, Alejandro; Micheyl, Christophe; Bee, Mark A
2017-03-06
Noise is a ubiquitous source of errors in all forms of communication [1]. Noise-induced errors in speech communication, for example, make it difficult for humans to converse in noisy social settings, a challenge aptly named the "cocktail party problem" [2]. Many nonhuman animals also communicate acoustically in noisy social groups and thus face biologically analogous problems [3]. However, we know little about how the perceptual systems of receivers are evolutionarily adapted to avoid the costs of noise-induced errors in communication. In this study of Cope's gray treefrog (Hyla chrysoscelis; Hylidae), we investigated whether receivers exploit a potential statistical regularity present in noisy acoustic scenes to reduce errors in signal recognition and discrimination. We developed an anatomical/physiological model of the peripheral auditory system to show that temporal correlation in amplitude fluctuations across the frequency spectrum ("comodulation") [4-6] is a feature of the noise generated by large breeding choruses of sexually advertising males. In four psychophysical experiments, we investigated whether females exploit comodulation in background noise to mitigate noise-induced errors in evolutionarily critical mate-choice decisions. Subjects experienced fewer errors in recognizing conspecific calls and in selecting the calls of high-quality mates in the presence of simulated chorus noise that was comodulated. These data show unequivocally, and for the first time, that exploiting statistical regularities present in noisy acoustic scenes is an important biological strategy for solving cocktail-party-like problems in nonhuman animal communication. Copyright © 2017 Elsevier Ltd. All rights reserved.
Basic Studies on High Pressure Air Plasmas
2006-08-30
which must be added a 1.5 month salary to A. Bugayev for assistance in laser and optic techniques. 2 Part II Technical report Plasma-induced phase shift...two-wavelength heterodyne interferometry applied to atmospheric pressure air plasma 11.1 .A. Plasma-induced phase shift - Electron density...a driver, since the error on the frequency leads to an error on the phase shift. (c) Optical elements Mirrors Protected mirrors must be used to stand
NASA Technical Reports Server (NTRS)
Belcastro, C. M.
1984-01-01
Advanced composite aircraft designs include fault-tolerant computer-based digital control systems with thigh reliability requirements for adverse as well as optimum operating environments. Since aircraft penetrate intense electromagnetic fields during thunderstorms, onboard computer systems maya be subjected to field-induced transient voltages and currents resulting in functional error modes which are collectively referred to as digital system upset. A methodology was developed for assessing the upset susceptibility of a computer system onboard an aircraft flying through a lightning environment. Upset error modes in a general-purpose microprocessor were studied via tests which involved the random input of analog transients which model lightning-induced signals onto interface lines of an 8080-based microcomputer from which upset error data were recorded. The application of Markov modeling to upset susceptibility estimation is discussed and a stochastic model development.
Spectral purity study for IPDA lidar measurement of CO2
NASA Astrophysics Data System (ADS)
Ma, Hui; Liu, Dong; Xie, Chen-Bo; Tan, Min; Deng, Qian; Xu, Ji-Wei; Tian, Xiao-Min; Wang, Zhen-Zhu; Wang, Bang-Xin; Wang, Ying-Jian
2018-02-01
A high sensitivity and global covered observation of carbon dioxide (CO2) is expected by space-borne integrated path differential absorption (IPDA) lidar which has been designed as the next generation measurement. The stringent precision of space-borne CO2 data, for example 1ppm or better, is required to address the largest number of carbon cycle science questions. Spectral purity, which is defined as the ratio of effective absorbed energy to the total energy transmitted, is one of the most important system parameters of IPDA lidar which directly influences the precision of CO2. Due to the column averaged dry air mixing ratio of CO2 is inferred from comparison of the two echo pulse signals, the laser output usually accompanied by an unexpected spectrally broadband background radiation would posing significant systematic error. In this study, the spectral energy density line shape and spectral impurity line shape are modeled as Lorentz line shape for the simulation, and the latter is assumed as an unabsorbed component by CO2. An error equation is deduced according to IPDA detecting theory for calculating the system error caused by spectral impurity. For a spectral purity of 99%, the induced error could reach up to 8.97 ppm.
Critical Care Performance in a Simulated Military Aircraft Cabin Environment.
McNeill, Margaret M
2018-04-01
Critical Care Air Transport Teams care for 5% to 10% of injured patients who are transported on military aircraft to definitive treatment facilities. Little is known about how the aeromedical evacuation environment affects care. To determine the effects of 2 stressors of flight, altitude-induced hypoxia and aircraft noise, and to examine the contributions of fatigue and clinical experience on cognitive and physiological performance of the Critical Care Air Transport Team. This repeated measures 2 × 2 × 4 factorial study included 60 military nurses. The participants completed a simulated patient care scenario under aircraft cabin noise and altitude conditions. Differences in cognitive and physiological performance were analyzed using repeated measures analysis of variance. A multiple regression model was developed to determine the independent contributions of fatigue and clinical experience. Critical care scores ( P = .02) and errors and omissions ( P = .047) were negatively affected by noise. Noise was associated with increased respiratory rate ( P = .02). Critical care scores ( P < .001) and errors and omissions ( P = .002) worsened with altitude-induced hypoxemia. Heart rate and respiratory rate increased with altitude-induced hypoxemia; oxygen saturation decreased ( P < .001 for all 3 variables). In a simulated military aircraft environment, the care of critically ill patients was significantly affected by noise and altitude-induced hypoxemia. The participants did not report much fatigue and experience did not play a role, contrary to most findings in the literature. ©2018 American Association of Critical-Care Nurses.
The Effects of Turbulence on Tthe Measurements of Five-Hole Probes
NASA Astrophysics Data System (ADS)
Diebold, Jeffrey Michael
The primary goals of this research were to quantify the effects of turbulence on the measurements of five-hole pressure probes (5HP) and to develop a model capable of predicting the response of a 5HP to turbulence. The five-hole pressure probe is a commonly used device in experimental fluid dynamics and aerodynamics. By measuring the pressure at the five pressure ports located on the tip of the probe it is possible to determine the total pressure, static pressure and the three components of velocity at a point in the flow. Previous research has demonstrated that the measurements of simple pressure probes such as Pitot probes are significantly influenced by the presence of turbulence. Turbulent velocity fluctuations contaminate the measurement of pressure due to the nonlinear relationship between pressure and velocity as well as the angular response characteristics of the probe. Despite our understanding of the effects of turbulence on Pitot and static pressure probes, relatively little is known about the influence of turbulence on five-hole probes. This study attempts to fill this gap in our knowledge by using advanced experimental techniques to quantify these turbulence-induced errors and by developing a novel method of predicting the response of a five-hole probe to turbulence. A few studies have attempted to quantify turbulence-induced errors in five-hole probe measurements but they were limited by their inability to accurately measure the total and static pressure in the turbulent flow. The current research utilizes a fast-response five-hole probe (FR5HP) in order to accurately quantify the effects of turbulence on different standard five-hole probes (Std5HP). The FR5HP is capable of measuring the instantaneous flowfield and unlike the Std5HP the FR5HP measurements are not contaminated by the turbulent velocity fluctuations. Measurements with the FR5HP and two different Std5HPs were acquired in the highly turbulent wakes of 2D and 3D cylinders in order to quantify the turbulence-induced errors in Std5HP measurements. The primary contribution of this work is the development and validation of a simulation method to predict the measurements of a Std5HP in an arbitrary turbulent flow. This simulation utilizes a statistical approach to estimating the pressure at each port on the tip of the probe. The angular response of the probe is modeled using experimental calibration data for each five-hole probe. The simulation method is validated against the experimental measurements of the Std5HPs, and then used to study the how the characteristics of the turbulent flowfield influence the measurements of the Std5HPs. It is shown that total pressure measured by a Std5HP is increased by axial velocity fluctuations but decreased by the transverse fluctuations. The static pressure was shown to be very sensitive to the transverse fluctuations while the axial fluctuations had a negligible effect. As with Pitot probes, the turbulence-induced errors in the Std5HPs measurements were dependent on both the properties of the turbulent flow and the geometry of the probe tip. It is then demonstrated that this simulation method can be used to correct the measurements of a Std5HP in a turbulent flow if the characteristics of the turbulence are known. Finally, it is demonstrated that turbulence-induced errors in Std5HP measurements can have a substantial effect on the determination of the profile and vortex-induced drag from measurements in the wake of a 3D body. The results showed that while the calculation of both drag components was influenced by turbulence-induced errors the largest effect was on the determination of vortex-induced drag.
Computation and measurement of cell decision making errors using single cell data
Habibi, Iman; Cheong, Raymond; Levchenko, Andre; Emamian, Effat S.; Abdi, Ali
2017-01-01
In this study a new computational method is developed to quantify decision making errors in cells, caused by noise and signaling failures. Analysis of tumor necrosis factor (TNF) signaling pathway which regulates the transcription factor Nuclear Factor κB (NF-κB) using this method identifies two types of incorrect cell decisions called false alarm and miss. These two events represent, respectively, declaring a signal which is not present and missing a signal that does exist. Using single cell experimental data and the developed method, we compute false alarm and miss error probabilities in wild-type cells and provide a formulation which shows how these metrics depend on the signal transduction noise level. We also show that in the presence of abnormalities in a cell, decision making processes can be significantly affected, compared to a wild-type cell, and the method is able to model and measure such effects. In the TNF—NF-κB pathway, the method computes and reveals changes in false alarm and miss probabilities in A20-deficient cells, caused by cell’s inability to inhibit TNF-induced NF-κB response. In biological terms, a higher false alarm metric in this abnormal TNF signaling system indicates perceiving more cytokine signals which in fact do not exist at the system input, whereas a higher miss metric indicates that it is highly likely to miss signals that actually exist. Overall, this study demonstrates the ability of the developed method for modeling cell decision making errors under normal and abnormal conditions, and in the presence of transduction noise uncertainty. Compared to the previously reported pathway capacity metric, our results suggest that the introduced decision error metrics characterize signaling failures more accurately. This is mainly because while capacity is a useful metric to study information transmission in signaling pathways, it does not capture the overlap between TNF-induced noisy response curves. PMID:28379950
Computation and measurement of cell decision making errors using single cell data.
Habibi, Iman; Cheong, Raymond; Lipniacki, Tomasz; Levchenko, Andre; Emamian, Effat S; Abdi, Ali
2017-04-01
In this study a new computational method is developed to quantify decision making errors in cells, caused by noise and signaling failures. Analysis of tumor necrosis factor (TNF) signaling pathway which regulates the transcription factor Nuclear Factor κB (NF-κB) using this method identifies two types of incorrect cell decisions called false alarm and miss. These two events represent, respectively, declaring a signal which is not present and missing a signal that does exist. Using single cell experimental data and the developed method, we compute false alarm and miss error probabilities in wild-type cells and provide a formulation which shows how these metrics depend on the signal transduction noise level. We also show that in the presence of abnormalities in a cell, decision making processes can be significantly affected, compared to a wild-type cell, and the method is able to model and measure such effects. In the TNF-NF-κB pathway, the method computes and reveals changes in false alarm and miss probabilities in A20-deficient cells, caused by cell's inability to inhibit TNF-induced NF-κB response. In biological terms, a higher false alarm metric in this abnormal TNF signaling system indicates perceiving more cytokine signals which in fact do not exist at the system input, whereas a higher miss metric indicates that it is highly likely to miss signals that actually exist. Overall, this study demonstrates the ability of the developed method for modeling cell decision making errors under normal and abnormal conditions, and in the presence of transduction noise uncertainty. Compared to the previously reported pathway capacity metric, our results suggest that the introduced decision error metrics characterize signaling failures more accurately. This is mainly because while capacity is a useful metric to study information transmission in signaling pathways, it does not capture the overlap between TNF-induced noisy response curves.
Daniels, Brianne H; McComb, Rodney D; Mobley, Bret C; Gultekin, Sakir Humayun; Lee, Han S; Margeta, Marta
2013-07-01
Autophagic vacuolar cardiomyopathy is an underrecognized, but potentially fatal, complication of treatment with chloroquine (CQ) and its derivative hydroxychloroquine (HCQ), which are used as therapy for malaria and common connective tissue disorders. Currently, the diagnosis of autophagic vacuolar cardiomyopathy is established through an endomyocardial biopsy and requires electron microscopy, which is not widely available and has a significant potential for sampling error. Recently, we have reported that immunohistochemistry for autophagic markers LC3 and p62 can replace electron microscopy in the diagnosis of HCQ-induced and colchicine-induced autophagic vacuolar skeletal myopathies. In the current study, we use 3 cases of CQ-induced or HCQ-induced cardiomyopathy and 1 HCQ-treated control case to show that the same two markers can be used to diagnose autophagic vacuolar cardiomyopathies by light microscopy. CQ-induced or HCQ-induced autophagic vacuolar cardiomyopathy is not universally fatal, but successful treatment requires early detection. By lowering the barriers to diagnosis, the application of these immunohistochemical markers will decrease the number of misdiagnosed patients, thus increasing the likelihood of favorable clinical outcomes.
Acute stress influences the discrimination of complex scenes and complex faces in young healthy men.
Paul, M; Lech, R K; Scheil, J; Dierolf, A M; Suchan, B; Wolf, O T
2016-04-01
The stress-induced release of glucocorticoids has been demonstrated to influence hippocampal functions via the modulation of specific receptors. At the behavioral level stress is known to influence hippocampus dependent long-term memory. In recent years, studies have consistently associated the hippocampus with the non-mnemonic perception of scenes, while adjacent regions in the medial temporal lobe were associated with the perception of objects, and faces. So far it is not known whether and how stress influences non-mnemonic perceptual processes. In a behavioral study, fifty male participants were subjected either to the stressful socially evaluated cold-pressor test or to a non-stressful control procedure, before they completed a visual discrimination task, comprising scenes and faces. The complexity of the face and scene stimuli was manipulated in easy and difficult conditions. A significant three way interaction between stress, stimulus type and complexity was found. Stressed participants tended to commit more errors in the complex scenes condition. For complex faces a descriptive tendency in the opposite direction (fewer errors under stress) was observed. As a result the difference between the number of errors for scenes and errors for faces was significantly larger in the stress group. These results indicate that, beyond the effects of stress on long-term memory, stress influences the discrimination of spatial information, especially when the perception is characterized by a high complexity. Copyright © 2016 Elsevier Ltd. All rights reserved.
Tramonti Fantozzi, Maria Paola; De Cicco, Vincenzo; Barresi, Massimo; Cataldo, Enrico; Faraguna, Ugo; Bruschini, Luca; Manzoni, Diego
2017-01-01
Trigeminal input to the ascending activating system is important for the maintenance of arousal and may affect the discharge of the noradrenergic neurons of the locus coeruleus (LC), whose activity influences both vigilance state and pupil size, inducing mydriasis. For this reason, pupil size evaluation is now considered an indicator of LC activity. Since mastication activates trigeminal afferent neurons, the aims of the present study, conducted on healthy adult participants, were to investigate whether chewing a bolus of different hardness may: (1) differentially affect the performance on a cognitive task (consisting in the retrieval of specific target numbers within numerical matrices) and (2) increase the dilatation of the pupil (mydriasis) induced by a haptic task, suggesting a change in LC activation. Results show that chewing significantly increased both the velocity of number retrieval (without affecting the number of errors) and the mydriasis associated with the haptic task, whereas simple task repetition did not modify either retrieval or mydriasis. Handgrip exercise, instead, significantly decreased both parameters. Effects were significantly stronger and longer lasting when subjects chewed hard pellets. Finally, chewing-induced improvements in performance and changes in mydriasis were positively correlated, which suggests that trigeminal signals enhanced by chewing may boost the cognitive performance by increasing LC activity. PMID:28848404
Li, Wenxun; Matin, Leonard
2005-03-01
Measurements were made of the accuracy of open-loop manual pointing and height-matching to a visual target whose elevation was perceptually mislocalized. Accuracy increased linearly with distance of the hand from the body, approaching complete accuracy at full extension; with the hand close to the body (within the midfrontal plane), the manual errors equaled the magnitude of the perceptual mislocalization. The visual inducing stimulus responsible for the perceptual errors was a single pitched-from-vertical line that was long (50 degrees), eccentrically-located (25 degrees horizontal), and viewed in otherwise total darkness. The line induced perceptual errors in the elevation of a small, circular visual target set to appear at eye level (VPEL), a setting that changed linearly with the change in the line's visual pitch as has been previously reported (pitch: -30 degrees topbackward to 30 degrees topforward); the elevation errors measured by VPEL settings varied systematically with pitch through an 18 degrees range. In a fourth experiment the visual inducing stimulus responsible for the perceptual errors was shown to induce separately-measured errors in the manual setting of the arm to feel horizontal that were also distance-dependent. The distance-dependence of the visually-induced changes in felt arm position accounts quantitatively for the distance-dependence of the manual errors in pointing/reaching and height matching to the visual target: The near equality of the changes in felt horizontal and changes in pointing/reaching with the finger at the end of the fully extended arm is responsible for the manual accuracy of the fully-extended point; with the finger in the midfrontal plane their large difference is responsible for the inaccuracies of the midfrontal-plane point. The results are inconsistent with the widely-held but controversial theory that visual spatial information employed for perception and action are dissociated and different with no illusory visual influence on action. A different two-system theory, the Proximal/Distal model, employing the same signals from vision and from the body-referenced mechanism with different weights for different hand-to-body distances, accounts for both the perceptual and the manual results in the present experiments.
Al-Obaidi, Saud; Al-Sayegh, Nowall; Nadar, Mohammed
2014-07-01
Grip strength assessment reflects on overall health of the musculoskeletal system and is a predictor of functional prognosis and mortality. The purpose of this study was: examine whether grip-strength and fatigue resistance are impaired in smokers, determine if smoking-related impairments (fatigue-index) can be predicted by demographic data, duration of smoking, packets smoked-per-day, and physical activity. Maximum isometric grip strength (MIGS) of male smokers (n = 111) and nonsmokers (n = 66) was measured before/after induced fatigue using Jamar dynamometer at 5-handle positions. Fatigue index was calculated based on percentage change in MIGS initially and after induced fatigue. Number of repetitions to squeeze the soft rubber ball to induce fatigue was significantly lower in smokers compared with nonsmokers (t = 10.6, P < .001 dominant hand; t = 13.9, P < .001 nondominant), demonstrating a significantly higher fatigue-index for smokers than nonsmokers (t = -8.7, P < .001 dominant hand; t = -6.0, P < .001 nondominant). The effect of smoking status on MIGS scores was significantly different between smokers and nonsmokers after induced fatigue (β = -3.98, standard error = 0.59, P < .001) where smokers experienced on average a reduction of nearly 4 MIGS less than nonsmokers before fatigue. Smoking status was the strongest significant independent predictor of the fatigue-index. Smokers demonstrated reduced grip strength and fast fatigability in comparison with nonsmokers.
Sources of errors in the simulation of south Asian summer monsoon in the CMIP5 GCMs
Ashfaq, Moetasim; Rastogi, Deeksha; Mei, Rui; ...
2016-09-19
Accurate simulation of the South Asian summer monsoon (SAM) is still an unresolved challenge. There has not been a benchmark effort to decipher the origin of undesired yet virtually invariable unsuccessfulness of general circulation models (GCMs) over this region. This study analyzes a large ensemble of CMIP5 GCMs to show that most of the simulation errors in the precipitation distribution and their driving mechanisms are systematic and of similar nature across the GCMs, with biases in meridional differential heating playing a critical role in determining the timing of monsoon onset over land, the magnitude of seasonal precipitation distribution and themore » trajectories of monsoon depressions. Errors in the pre-monsoon heat low over the lower latitudes and atmospheric latent heating over the slopes of Himalayas and Karakoram Range induce significant errors in the atmospheric circulations and meridional differential heating. Lack of timely precipitation further exacerbates such errors by limiting local moisture recycling and latent heating aloft from convection. Most of the summer monsoon errors and their sources are reproducible in the land–atmosphere configuration of a GCM when it is configured at horizontal grid spacing comparable to the CMIP5 GCMs. While an increase in resolution overcomes many modeling challenges, coarse resolution is not necessarily the primary driver in the exhibition of errors over South Asia. Ultimately, these results highlight the importance of previously less well known pre-monsoon mechanisms that critically influence the strength of SAM in the GCMs and highlight the importance of land–atmosphere interactions in the development and maintenance of SAM.« less
Dominant Drivers of GCMs Errors in the Simulation of South Asian Summer Monsoon
NASA Astrophysics Data System (ADS)
Ashfaq, Moetasim
2017-04-01
Accurate simulation of the South Asian summer monsoon (SAM) is a longstanding unresolved problem in climate modeling science. There has not been a benchmark effort to decipher the origin of undesired yet virtually invariable unsuccessfulness of general circulation models (GCMs) over this region. This study analyzes a large ensemble of CMIP5 GCMs to demonstrate that most of the simulation errors in the summer season and their driving mechanisms are systematic and of similar nature across the GCMs, with biases in meridional differential heating playing a critical role in determining the timing of monsoon onset over land, the magnitude of seasonal precipitation distribution and the trajectories of monsoon depressions. Errors in the pre-monsoon heat low over the lower latitudes and atmospheric latent heating over the slopes of Himalayas and Karakoram Range induce significant errors in the atmospheric circulations and meridional differential heating. Lack of timely precipitation over land further exacerbates such errors by limiting local moisture recycling and latent heating aloft from convection. Most of the summer monsoon errors and their sources are reproducible in the land-atmosphere configuration of a GCM when it is configured at horizontal grid spacing comparable to the CMIP5 GCMs. While an increase in resolution overcomes many modeling challenges, coarse resolution is not necessarily the primary driver in the exhibition of errors over South Asia. These results highlight the importance of previously less well known pre-monsoon mechanisms that critically influence the strength of SAM in the GCMs and highlight the importance of land-atmosphere interactions in the development and maintenance of SAM.
Long-term orbit prediction for China's Tiangong-1 spacecraft based on mean atmosphere model
NASA Astrophysics Data System (ADS)
Tang, Jingshi; Liu, Lin; Miao, Manqian
Tiangong-1 is China's test module for future space station. It has gone through three successful rendezvous and dockings with Shenzhou spacecrafts from 2011 to 2013. For the long-term management and maintenance, the orbit sometimes needs to be predicted for a long period of time. As Tiangong-1 works in a low-Earth orbit with an altitude of about 300-400 km, the error in the a priori atmosphere model contributes significantly to the rapid increase of the predicted orbit error. When the orbit is predicted for 10-20 days, the error in the a priori atmosphere model, if not properly corrected, could induce the semi-major axis error and the overall position error up to a few kilometers and several thousand kilometers respectively. In this work, we use a mean atmosphere model averaged from NRLMSIS00. The a priori reference mean density can be corrected during precise orbit determination (POD). For applications in the long-term orbit prediction, the observations are first accumulated. With sufficiently long period of observations, we are able to obtain a series of the diurnal mean densities. This series bears the recent variation of the atmosphere density and can be analyzed for various periods. After being properly fitted, the mean density can be predicted and then applied in the orbit prediction. We show that the densities predicted with this approach can serve to increase the accuracy of the predicted orbit. In several 20-day prediction tests, most predicted orbits show semi-major axis errors better than 700m and overall position errors better than 600km.
Sources of errors in the simulation of south Asian summer monsoon in the CMIP5 GCMs
NASA Astrophysics Data System (ADS)
Ashfaq, Moetasim; Rastogi, Deeksha; Mei, Rui; Touma, Danielle; Ruby Leung, L.
2017-07-01
Accurate simulation of the South Asian summer monsoon (SAM) is still an unresolved challenge. There has not been a benchmark effort to decipher the origin of undesired yet virtually invariable unsuccessfulness of general circulation models (GCMs) over this region. This study analyzes a large ensemble of CMIP5 GCMs to show that most of the simulation errors in the precipitation distribution and their driving mechanisms are systematic and of similar nature across the GCMs, with biases in meridional differential heating playing a critical role in determining the timing of monsoon onset over land, the magnitude of seasonal precipitation distribution and the trajectories of monsoon depressions. Errors in the pre-monsoon heat low over the lower latitudes and atmospheric latent heating over the slopes of Himalayas and Karakoram Range induce significant errors in the atmospheric circulations and meridional differential heating. Lack of timely precipitation further exacerbates such errors by limiting local moisture recycling and latent heating aloft from convection. Most of the summer monsoon errors and their sources are reproducible in the land-atmosphere configuration of a GCM when it is configured at horizontal grid spacing comparable to the CMIP5 GCMs. While an increase in resolution overcomes many modeling challenges, coarse resolution is not necessarily the primary driver in the exhibition of errors over South Asia. These results highlight the importance of previously less well known pre-monsoon mechanisms that critically influence the strength of SAM in the GCMs and highlight the importance of land-atmosphere interactions in the development and maintenance of SAM.
Lack of dependence on resonant error field of locked mode island size in ohmic plasmas in DIII-D
NASA Astrophysics Data System (ADS)
La Haye, R. J.; Paz-Soldan, C.; Strait, E. J.
2015-02-01
DIII-D experiments show that fully penetrated resonant n = 1 error field locked modes in ohmic plasmas with safety factor q95 ≳ 3 grow to similar large disruptive size, independent of resonant error field correction. Relatively small resonant (m/n = 2/1) static error fields are shielded in ohmic plasmas by the natural rotation at the electron diamagnetic drift frequency. However, the drag from error fields can lower rotation such that a bifurcation results, from nearly complete shielding to full penetration, i.e., to a driven locked mode island that can induce disruption. Error field correction (EFC) is performed on DIII-D (in ITER relevant shape and safety factor q95 ≳ 3) with either the n = 1 C-coil (no handedness) or the n = 1 I-coil (with ‘dominantly’ resonant field pitch). Despite EFC, which allows significantly lower plasma density (a ‘figure of merit’) before penetration occurs, the resulting saturated islands have similar large size; they differ only in the phase of the locked mode after typically being pulled (by up to 30° toroidally) in the electron diamagnetic drift direction as they grow to saturation. Island amplification and phase shift are explained by a second change-of-state in which the classical tearing index changes from stable to marginal by the presence of the island, which changes the current density profile. The eventual island size is thus governed by the inherent stability and saturation mechanism rather than the driving error field.
Sources of errors in the simulation of south Asian summer monsoon in the CMIP5 GCMs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ashfaq, Moetasim; Rastogi, Deeksha; Mei, Rui
2016-09-19
Accurate simulation of the South Asian summer monsoon (SAM) is still an unresolved challenge. There has not been a benchmark effort to decipher the origin of undesired yet virtually invariable unsuccessfulness of general circulation models (GCMs) over this region. This study analyzes a large ensemble of CMIP5 GCMs to show that most of the simulation errors in the precipitation distribution and their driving mechanisms are systematic and of similar nature across the GCMs, with biases in meridional differential heating playing a critical role in determining the timing of monsoon onset over land, the magnitude of seasonal precipitation distribution and themore » trajectories of monsoon depressions. Errors in the pre-monsoon heat low over the lower latitudes and atmospheric latent heating over the slopes of Himalayas and Karakoram Range induce significant errors in the atmospheric circulations and meridional differential heating. Lack of timely precipitation further exacerbates such errors by limiting local moisture recycling and latent heating aloft from convection. Most of the summer monsoon errors and their sources are reproducible in the land–atmosphere configuration of a GCM when it is configured at horizontal grid spacing comparable to the CMIP5 GCMs. While an increase in resolution overcomes many modeling challenges, coarse resolution is not necessarily the primary driver in the exhibition of errors over South Asia. These results highlight the importance of previously less well known pre-monsoon mechanisms that critically influence the strength of SAM in the GCMs and highlight the importance of land–atmosphere interactions in the development and maintenance of SAM.« less
NASA Astrophysics Data System (ADS)
Peres, David J.; Cancelliere, Antonino; Greco, Roberto; Bogaard, Thom A.
2018-03-01
Uncertainty in rainfall datasets and landslide inventories is known to have negative impacts on the assessment of landslide-triggering thresholds. In this paper, we perform a quantitative analysis of the impacts of uncertain knowledge of landslide initiation instants on the assessment of rainfall intensity-duration landslide early warning thresholds. The analysis is based on a synthetic database of rainfall and landslide information, generated by coupling a stochastic rainfall generator and a physically based hydrological and slope stability model, and is therefore error-free in terms of knowledge of triggering instants. This dataset is then perturbed according to hypothetical reporting scenarios
that allow simulation of possible errors in landslide-triggering instants as retrieved from historical archives. The impact of these errors is analysed jointly using different criteria to single out rainfall events from a continuous series and two typical temporal aggregations of rainfall (hourly and daily). The analysis shows that the impacts of the above uncertainty sources can be significant, especially when errors exceed 1 day or the actual instants follow the erroneous ones. Errors generally lead to underestimated thresholds, i.e. lower than those that would be obtained from an error-free dataset. Potentially, the amount of the underestimation can be enough to induce an excessive number of false positives, hence limiting possible landslide mitigation benefits. Moreover, the uncertain knowledge of triggering rainfall limits the possibility to set up links between thresholds and physio-geographical factors.
The Effects of Vibration and Muscle Fatigue on Trunk Sensorimotor Control in Low Back Pain Patients
Abboud, Jacques; Nougarou, François; Normand, Martin C.
2015-01-01
Introduction Changes in sensorimotor function and increased trunk muscle fatigability have been identified in patients with chronic low back pain (cLBP). This study assessed the control of trunk force production in conditions with and without local erector spinae muscle vibration and evaluated the influence of muscle fatigue on trunk sensorimotor control. Methods Twenty non-specific cLBP patients and 20 healthy participants were asked to perform submaximal isometric trunk extension torque with and without local vibration stimulation, before and after a trunk extensor muscle fatigue protocol. Constant error (CE), variable error (VE) as well as absolute error (AE) in peak torque were computed and compared across conditions. Trunk extensor muscle activation during isometric contractions and during the fatigue protocol was measured using surface electromyography (sEMG). Results Force reproduction accuracy of the trunk was significantly lower in the patient group (CE = 9.81 ± 2.23 Nm; AE = 18.16 ± 3.97 Nm) than in healthy participants (CE = 4.44 ± 1.68 Nm; AE = 12.23 ± 2.44 Nm). Local erector spinae vibration induced a significant reduction in CE (4.33 ± 2.14 Nm) and AE (13.71 ± 3.45 Nm) mean scores in the patient group. Healthy participants conversely showed a significant increase in CE (8.17 ± 2.10 Nm) and AE (16.29 ± 2.82 Nm) mean scores under vibration conditions. The fatigue protocol induced erector spinae muscle fatigue as illustrated by a significant decrease in sEMG median time-frequency slopes. Following the fatigue protocol, patients with cLBP showed significant decrease in sEMG root mean square activity at L4-5 level and responded in similar manner with and without vibration stimulation in regard to CE mean scores. Conclusions Patients with cLBP have a less accurate force reproduction sense than healthy participants. Local muscle vibration led to significant trunk neuromuscular control improvements in the cLBP patients before and after a muscle fatigue protocol. Muscle vibration stimulation during motor control exercises is likely to influence motor adaptation and could be considered in the treatment of cLBP. Further work is needed to clearly identify at what levels of the sensorimotor system these gains are achievable. PMID:26308725
The Effects of Vibration and Muscle Fatigue on Trunk Sensorimotor Control in Low Back Pain Patients.
Boucher, Jean-Alexandre; Abboud, Jacques; Nougarou, François; Normand, Martin C; Descarreaux, Martin
2015-01-01
Changes in sensorimotor function and increased trunk muscle fatigability have been identified in patients with chronic low back pain (cLBP). This study assessed the control of trunk force production in conditions with and without local erector spinae muscle vibration and evaluated the influence of muscle fatigue on trunk sensorimotor control. Twenty non-specific cLBP patients and 20 healthy participants were asked to perform submaximal isometric trunk extension torque with and without local vibration stimulation, before and after a trunk extensor muscle fatigue protocol. Constant error (CE), variable error (VE) as well as absolute error (AE) in peak torque were computed and compared across conditions. Trunk extensor muscle activation during isometric contractions and during the fatigue protocol was measured using surface electromyography (sEMG). Force reproduction accuracy of the trunk was significantly lower in the patient group (CE = 9.81 ± 2.23 Nm; AE = 18.16 ± 3.97 Nm) than in healthy participants (CE = 4.44 ± 1.68 Nm; AE = 12.23 ± 2.44 Nm). Local erector spinae vibration induced a significant reduction in CE (4.33 ± 2.14 Nm) and AE (13.71 ± 3.45 Nm) mean scores in the patient group. Healthy participants conversely showed a significant increase in CE (8.17 ± 2.10 Nm) and AE (16.29 ± 2.82 Nm) mean scores under vibration conditions. The fatigue protocol induced erector spinae muscle fatigue as illustrated by a significant decrease in sEMG median time-frequency slopes. Following the fatigue protocol, patients with cLBP showed significant decrease in sEMG root mean square activity at L4-5 level and responded in similar manner with and without vibration stimulation in regard to CE mean scores. Patients with cLBP have a less accurate force reproduction sense than healthy participants. Local muscle vibration led to significant trunk neuromuscular control improvements in the cLBP patients before and after a muscle fatigue protocol. Muscle vibration stimulation during motor control exercises is likely to influence motor adaptation and could be considered in the treatment of cLBP. Further work is needed to clearly identify at what levels of the sensorimotor system these gains are achievable.
Decay of motor memories in the absence of error
Vaswani, Pavan A.; Shadmehr, Reza
2013-01-01
When motor commands are accompanied by an unexpected outcome, the resulting error induces changes in subsequent commands. However, when errors are artificially eliminated, changes in motor commands are not sustained, but show decay. Why does the adaptation-induced change in motor output decay in the absence of error? A prominent idea is that decay reflects the stability of the memory. We show results that challenge this idea and instead suggest that motor output decays because the brain actively disengages a component of the memory. Humans adapted their reaching movements to a perturbation and were then introduced to a long period of trials in which errors were absent (error-clamp). We found that, in some subjects, motor output did not decay at the onset of the error-clamp block, but a few trials later. We manipulated the kinematics of movements in the error-clamp block and found that as movements became more similar to subjects’ natural movements in the perturbation block, the lag to decay onset became longer and eventually reached hundreds of trials. Furthermore, when there was decay in the motor output, the endpoint of decay was not zero, but a fraction of the motor memory that was last acquired. Therefore, adaptation to a perturbation installed two distinct kinds of memories: one that was disengaged when the brain detected a change in the task, and one that persisted despite it. Motor memories showed little decay in the absence of error if the brain was prevented from detecting a change in task conditions. PMID:23637163
The Investigation of Pointing Behaviors in Web Browsing
2016-09-26
fast movements have a different error model from slow movements and study the impact induced by the open-loop nature of fast 1. REPORT DATE (DD-MM-YYYY...whether or not fast movements have a different error model from slow movements and study the impact induced by the open-loop nature of fast movements. (3...PI will comparison of Fitts’ law results for natural browsing using two different pointing devices: physical mouse and laptop touchpad in order to
Effect of cooling on thixotropic position-sense error in human biceps muscle.
Sekihara, Chikara; Izumizaki, Masahiko; Yasuda, Tomohiro; Nakajima, Takayuki; Atsumi, Takashi; Homma, Ikuo
2007-06-01
Muscle temperature affects muscle thixotropy. However, it is unclear whether changes in muscle temperature affect thixotropic position-sense errors. We studied the effect of cooling on thixotropic position-sense errors induced by short-length muscle contraction (hold-short conditioning) in the biceps of 12 healthy men. After hold-short conditioning of the right biceps muscle in a cooled (5.0 degrees C) or control (36.5 degrees C) environment, subjects perceived greater extension of the conditioned forearm at 5.0 degrees C. The angle differences between the two forearms following hold-short conditioning of the right biceps muscle in normal or cooled conditions were significantly different (-3.335 +/- 1.680 degrees at 36.5 degrees C vs. -5.317 +/- 1.096 degrees at 5.0 degrees C; P=0.043). Induction of a tonic vibration reflex in the biceps muscle elicited involuntary forearm elevation, and the angular velocities of the elevation differed significantly between arms conditioned in normal and cooled environments (1.583 +/- 0.326 degrees /s at 36.5 degrees C vs. 3.100 +/- 0.555 degrees /s at 5.0 degrees C, P=0.0039). Thus, a cooled environment impairs a muscle's ability to provide positional information, potentially leading to poor muscle performance.
Robust dynamic 3-D measurements with motion-compensated phase-shifting profilometry
NASA Astrophysics Data System (ADS)
Feng, Shijie; Zuo, Chao; Tao, Tianyang; Hu, Yan; Zhang, Minliang; Chen, Qian; Gu, Guohua
2018-04-01
Phase-shifting profilometry (PSP) is a widely used approach to high-accuracy three-dimensional shape measurements. However, when it comes to moving objects, phase errors induced by the movement often result in severe artifacts even though a high-speed camera is in use. From our observations, there are three kinds of motion artifacts: motion ripples, motion-induced phase unwrapping errors, and motion outliers. We present a novel motion-compensated PSP to remove the artifacts for dynamic measurements of rigid objects. The phase error of motion ripples is analyzed for the N-step phase-shifting algorithm and is compensated using the statistical nature of the fringes. The phase unwrapping errors are corrected exploiting adjacent reliable pixels, and the outliers are removed by comparing the original phase map with a smoothed phase map. Compared with the three-step PSP, our method can improve the accuracy by more than 95% for objects in motion.
Covariate Measurement Error Correction Methods in Mediation Analysis with Failure Time Data
Zhao, Shanshan
2014-01-01
Summary Mediation analysis is important for understanding the mechanisms whereby one variable causes changes in another. Measurement error could obscure the ability of the potential mediator to explain such changes. This paper focuses on developing correction methods for measurement error in the mediator with failure time outcomes. We consider a broad definition of measurement error, including technical error and error associated with temporal variation. The underlying model with the ‘true’ mediator is assumed to be of the Cox proportional hazards model form. The induced hazard ratio for the observed mediator no longer has a simple form independent of the baseline hazard function, due to the conditioning event. We propose a mean-variance regression calibration approach and a follow-up time regression calibration approach, to approximate the partial likelihood for the induced hazard function. Both methods demonstrate value in assessing mediation effects in simulation studies. These methods are generalized to multiple biomarkers and to both case-cohort and nested case-control sampling design. We apply these correction methods to the Women's Health Initiative hormone therapy trials to understand the mediation effect of several serum sex hormone measures on the relationship between postmenopausal hormone therapy and breast cancer risk. PMID:25139469
Covariate measurement error correction methods in mediation analysis with failure time data.
Zhao, Shanshan; Prentice, Ross L
2014-12-01
Mediation analysis is important for understanding the mechanisms whereby one variable causes changes in another. Measurement error could obscure the ability of the potential mediator to explain such changes. This article focuses on developing correction methods for measurement error in the mediator with failure time outcomes. We consider a broad definition of measurement error, including technical error, and error associated with temporal variation. The underlying model with the "true" mediator is assumed to be of the Cox proportional hazards model form. The induced hazard ratio for the observed mediator no longer has a simple form independent of the baseline hazard function, due to the conditioning event. We propose a mean-variance regression calibration approach and a follow-up time regression calibration approach, to approximate the partial likelihood for the induced hazard function. Both methods demonstrate value in assessing mediation effects in simulation studies. These methods are generalized to multiple biomarkers and to both case-cohort and nested case-control sampling designs. We apply these correction methods to the Women's Health Initiative hormone therapy trials to understand the mediation effect of several serum sex hormone measures on the relationship between postmenopausal hormone therapy and breast cancer risk. © 2014, The International Biometric Society.
NASA Astrophysics Data System (ADS)
Mauder, M.; Huq, S.; De Roo, F.; Foken, T.; Manhart, M.; Schmid, H. P. E.
2017-12-01
The Campbell CSAT3 sonic anemometer is one of the most widely used instruments for eddy-covariance measurement. However, conflicting estimates for the probe-induced flow distortion error of this instrument have been reported recently, and those error estimates range between 3% and 14% for the measurement of vertical velocity fluctuations. This large discrepancy between the different studies can probably be attributed to the different experimental approaches applied. In order to overcome the limitations of both field intercomparison experiments and wind tunnel experiments, we propose a new approach that relies on virtual measurements in a large-eddy simulation (LES) environment. In our experimental set-up, we generate horizontal and vertical velocity fluctuations at frequencies that typically dominate the turbulence spectra of the surface layer. The probe-induced flow distortion error of a CSAT3 is then quantified by this numerical wind tunnel approach while the statistics of the prescribed inflow signal are taken as reference or etalon. The resulting relative error is found to range from 3% to 7% and from 1% to 3% for the standard deviation of the vertical and the horizontal velocity component, respectively, depending on the orientation of the CSAT3 in the flow field. We further demonstrate that these errors are independent of the frequency of fluctuations at the inflow of the simulation. The analytical corrections proposed by Kaimal et al. (Proc Dyn Flow Conf, 551-565, 1978) and Horst et al. (Boundary-Layer Meteorol, 155, 371-395, 2015) are compared against our simulated results, and we find that they indeed reduce the error by up to three percentage points. However, these corrections fail to reproduce the azimuth-dependence of the error that we observe. Moreover, we investigate the general Reynolds number dependence of the flow distortion error by more detailed idealized simulations.
Spatial compression impairs prism adaptation in healthy individuals.
Scriven, Rachel J; Newport, Roger
2013-01-01
Neglect patients typically present with gross inattention to one side of space following damage to the contralateral hemisphere. While prism-adaptation (PA) is effective in ameliorating some neglect behaviors, the mechanisms involved and their relationship to neglect remain unclear. Recent studies have shown that conscious strategic control (SC) processes in PA may be impaired in neglect patients, who are also reported to show extraordinarily long aftereffects compared to healthy participants. Determining the underlying cause of these effects may be the key to understanding therapeutic benefits. Alternative accounts suggest that reduced SC might result from a failure to detect prism-induced reaching errors properly either because (a) the size of the error is underestimated in compressed visual space or (b) pathologically increased error-detection thresholds reduce the requirement for error correction. The purpose of this study was to model these two alternatives in healthy participants and to examine whether SC and subsequent aftereffects were abnormal compared to standard PA. Each participant completed three PA procedures within a MIRAGE mediated reality environment with direction errors recorded before, during and after adaptation. During PA, visual feedback of the reach could be compressed, perturbed by noise, or represented veridically. Compressed visual space significantly reduced SC and aftereffects compared to control and noise conditions. These results support recent observations in neglect patients, suggesting that a distortion of spatial representation may successfully model neglect and explain neglect performance while adapting to prisms.
2010-08-31
not defined. Figure 5.9: Run 10-Schlieren image with only the laser-induced air-breakdown glow visible. (M=8.77, T∞=68.7 K , P∞=0.15 kPa...Run #13-Laser induced blast wave interaction with oblique shock. (M-5.95, T∞=263.7 K , P∞=5.62 kPa, Ep=196±20 J) ................ Error! Bookmark not...the air-breakdown geometry. (M-5.95, T∞=262.3 K , P∞=5.16 kPa, Ep=176±18 J)Error! Bookmark not defined. Figure 5.13: Run#16 - Laser induced blast
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wojahn, Christopher K.
2015-10-20
This HDL code (hereafter referred to as "software") implements circuitry in Xilinx Virtex-5QV Field Programmable Gate Array (FPGA) hardware. This software allows the device to self-check the consistency of its own configuration memory for radiation-induced errors. The software then provides the capability to correct any single-bit errors detected in the memory using the device's inherent circuitry, or reload corrupted memory frames when larger errors occur that cannot be corrected with the device's built-in error correction and detection scheme.
Error compensation for thermally induced errors on a machine tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krulewich, D.A.
1996-11-08
Heat flow from internal and external sources and the environment create machine deformations, resulting in positioning errors between the tool and workpiece. There is no industrially accepted method for thermal error compensation. A simple model has been selected that linearly relates discrete temperature measurements to the deflection. The biggest problem is how to locate the temperature sensors and to determine the number of required temperature sensors. This research develops a method to determine the number and location of temperature measurements.
Effect of partition board color on mood and autonomic nervous function.
Sakuragi, Sokichi; Sugiyama, Yoshiki
2011-12-01
The purpose of this study was to evaluate the effects of the presence or absence (control) of a partition board and its color (red, yellow, blue) on subjective mood ratings and changes in autonomic nervous system indicators induced by a video game task. The increase in the mean Profile of Mood States (POMS) Fatigue score and mean Oppressive feeling rating after the task was lowest with the blue partition board. Multiple-regression analysis identified oppressive feeling and error scores on the second half of the task as statistically significant contributors to Fatigue. While explanatory variables were limited to the physiological indices, multiple-regression analysis identified a significant contribution of autonomic reactivity (assessed by heart rate variability) to Fatigue. These results suggest that a blue partition board would reduce task-induced subjective fatigue, in part by lowering the oppressive feeling of being enclosed during the task, possibly by increasing autonomic reactivity.
Van, Anh T.; Weidlich, Dominik; Kooijman, Hendrick; Hock, Andreas; Rummeny, Ernst J.; Gersing, Alexandra; Kirschke, Jan S.; Karampinos, Dimitrios C.
2018-01-01
Purpose To perform in vivo isotropic‐resolution diffusion tensor imaging (DTI) of lumbosacral and sciatic nerves with a phase‐navigated diffusion‐prepared (DP) 3D turbo spin echo (TSE) acquisition and modified reconstruction incorporating intershot phase‐error correction and to investigate the improvement on image quality and diffusion quantification with the proposed phase correction. Methods Phase‐navigated DP 3D TSE included magnitude stabilizers to minimize motion and eddy‐current effects on the signal magnitude. Phase navigation of motion‐induced phase errors was introduced before readout in 3D TSE. DTI of lower back nerves was performed in vivo using 3D TSE and single‐shot echo planar imaging (ss‐EPI) in 13 subjects. Diffusion data were phase‐corrected per k z plane with respect to T2‐weighted data. The effects of motion‐induced phase errors on DTI quantification was assessed for 3D TSE and compared with ss‐EPI. Results Non–phase‐corrected 3D TSE resulted in artifacts in diffusion‐weighted images and overestimated DTI parameters in the sciatic nerve (mean diffusivity [MD] = 2.06 ± 0.45). Phase correction of 3D TSE DTI data resulted in reductions in all DTI parameters (MD = 1.73 ± 0.26) of statistical significance (P ≤ 0.001) and in closer agreement with ss‐EPI DTI parameters (MD = 1.62 ± 0.21). Conclusion DP 3D TSE with phase correction allows distortion‐free isotropic diffusion imaging of lower back nerves with robustness to motion‐induced artifacts and DTI quantification errors. Magn Reson Med 80:609–618, 2018. © 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. PMID:29380414
Chen, Yen-Po; Prashar, Ankush; Hocking, Paul M; Erichsen, Jonathan T; To, Chi Ho; Schaeffel, Frank; Guggenheim, Jeremy A
2010-02-01
There is considerable variation in the degree of form-deprivation myopia (FDM) induced in chickens by a uniform treatment regimen. Sex and pretreatment eye size have been found to be predictive of the rate of FD-induced eye growth. Therefore, this study was undertaken to test whether the greater rate of myopic eye growth in males is a consequence of their larger eyes or of some other aspect of their sex. Monocular FDM was induced in 4-day-old White Leghorn chicks for 4 days. Changes in ocular component dimensions and refractive error were assessed by A-scan ultrasonography and retinoscopy, respectively. Sex identification of chicks was performed by DNA test. Relationships between traits were assessed by multiple regression. FD produced (mean +/- SD) 13.47 +/- 3.12 D of myopia and 0.47 +/- 0.14 mm of vitreous chamber elongation. The level of induced myopia was not significantly different between the sexes, but the males had larger eyes initially and showed greater myopic eye growth than did the females. In multiple linear regression analysis, the partial correlation between sex and the degree of induced eye growth remained significant (P = 0.008) after adjustment for eye size, whereas the partial correlation between initial eye size and the degree of induced eye growth was no longer significant after adjustment for sex (P = 0.11). After adjustment for other factors, the chicks' sex accounted for 6.4% of the variation in FD-induced vitreous chamber elongation. The sex of the chick influences the rate of experimentally induced myopic eye growth, independent of its effects on eye size.
Analysis of the impact of error detection on computer performance
NASA Technical Reports Server (NTRS)
Shin, K. C.; Lee, Y. H.
1983-01-01
Conventionally, reliability analyses either assume that a fault/error is detected immediately following its occurrence, or neglect damages caused by latent errors. Though unrealistic, this assumption was imposed in order to avoid the difficulty of determining the respective probabilities that a fault induces an error and the error is then detected in a random amount of time after its occurrence. As a remedy for this problem a model is proposed to analyze the impact of error detection on computer performance under moderate assumptions. Error latency, the time interval between occurrence and the moment of detection, is used to measure the effectiveness of a detection mechanism. This model is used to: (1) predict the probability of producing an unreliable result, and (2) estimate the loss of computation due to fault and/or error.
Foster, Patricia L.; Lee, Heewook; Popodi, Ellen; Townes, Jesse P.; Tang, Haixu
2015-01-01
A complete understanding of evolutionary processes requires that factors determining spontaneous mutation rates and spectra be identified and characterized. Using mutation accumulation followed by whole-genome sequencing, we found that the mutation rates of three widely diverged commensal Escherichia coli strains differ only by about 50%, suggesting that a rate of 1–2 × 10−3 mutations per generation per genome is common for this bacterium. Four major forces are postulated to contribute to spontaneous mutations: intrinsic DNA polymerase errors, endogenously induced DNA damage, DNA damage caused by exogenous agents, and the activities of error-prone polymerases. To determine the relative importance of these factors, we studied 11 strains, each defective for a major DNA repair pathway. The striking result was that only loss of the ability to prevent or repair oxidative DNA damage significantly impacted mutation rates or spectra. These results suggest that, with the exception of oxidative damage, endogenously induced DNA damage does not perturb the overall accuracy of DNA replication in normally growing cells and that repair pathways may exist primarily to defend against exogenously induced DNA damage. The thousands of mutations caused by oxidative damage recovered across the entire genome revealed strong local-sequence biases of these mutations. Specifically, we found that the identity of the 3′ base can affect the mutability of a purine by oxidative damage by as much as eightfold. PMID:26460006
Optical communication system performance with tracking error induced signal fading.
NASA Technical Reports Server (NTRS)
Tycz, M.; Fitzmaurice, M. W.; Premo, D. A.
1973-01-01
System performance is determined for an optical communication system using noncoherent detection in the presence of tracking error induced signal fading assuming (1) binary on-off modulation (OOK) with both fixed and adaptive threshold receivers, and (2) binary polarization modulation (BPM). BPM is shown to maintain its inherent 2- to 3-dB advantage over OOK when adaptive thresholding is used, and to have a substantially greater advantage when the OOK system is restricted to a fixed decision threshold.
Papas, Athena S; Kugel, Gerard; Singh, Mabi; Barker, Matthew L; Gerlach, Robert W
2009-01-01
A randomized, double-blind, placebo-controlled clinical trial was conducted to evaluate the effectiveness and safety of peroxide-containing strip-based tooth whitening among subjects with medication-induced hyposalivation. Eligibility for this tooth whitening study was limited to dentate adults taking xerogenic medications with an unstimulated salivary flow < or = 0.2 ml/min. After giving informed consent, 42 subjects were randomized using a 2:1 ratio to 10% hydrogen peroxide whitening strips (Crest Whitestrips Premium) or placebo strips without peroxide. Strips were used for 30 min twice daily for a 14-day period. Usage was unsupervised, and only the maxillary arch was treated. On days 8 and 15, efficacy was assessed from standard digital images of the anterior dentition and quantified using the Cielab color system, while safety was assessed from interviews and clinical examinations. At day 8, the peroxide group experienced significant (p < 0.001) color improvement relative to baseline and placebo. Adjusted means +/- standard errors for yellowness reduction were -1.65 +/- 0.115 units for the peroxide group and -0.32 +/- 0.170 units for the placebo group. For the increase in lightness, adjusted means +/- standard errors on day 8 were 1.53 +/- 0.130 units for the peroxide group and 0.37 +/- 0.191 units for the controls. Continued strip use through day 15 yielded incremental color improvement for the peroxide group. Mild and transient tooth sensitivity represented the most common adverse events. No subject discontinued treatment due to a product-related adverse event. Twice daily use of 10% hydrogen peroxide whitening strips by adults with medication-induced xerostomia was well tolerated, with significant tooth color improvement evident within 7 days. Copyright 2009 S. Karger AG, Basel.
Time-dependent phase error correction using digital waveform synthesis
Doerry, Armin W.; Buskirk, Stephen
2017-10-10
The various technologies presented herein relate to correcting a time-dependent phase error generated as part of the formation of a radar waveform. A waveform can be pre-distorted to facilitate correction of an error induced into the waveform by a downstream operation/component in a radar system. For example, amplifier power droop effect can engender a time-dependent phase error in a waveform as part of a radar signal generating operation. The error can be quantified and an according complimentary distortion can be applied to the waveform to facilitate negation of the error during the subsequent processing of the waveform. A time domain correction can be applied by a phase error correction look up table incorporated into a waveform phase generator.
Huang, Juan; Hung, Li-Fang; Smith, Earl L.
2012-01-01
This study aimed to investigate the changes in ocular shape and relative peripheral refraction during the recovery from myopia produced by form deprivation (FD) and hyperopic defocus. FD was imposed in 6 monkeys by securing a diffuser lens over one eye; hyperopic defocus was produced in another 6 monkeys by fitting one eye with -3D spectacle. When unrestricted vision was re-established, the treated eyes recovered from the vision-induced central and peripheral refractive errors. The recovery of peripheral refractive errors was associated with corresponding changes in the shape of the posterior globe. The results suggest that vision can actively regulate ocular shape and the development of central and peripheral refractions in infant primates. PMID:23026012
Error catastrophe and phase transition in the empirical fitness landscape of HIV
NASA Astrophysics Data System (ADS)
Hart, Gregory R.; Ferguson, Andrew L.
2015-03-01
We have translated clinical sequence databases of the p6 HIV protein into an empirical fitness landscape quantifying viral replicative capacity as a function of the amino acid sequence. We show that the viral population resides close to a phase transition in sequence space corresponding to an "error catastrophe" beyond which there is lethal accumulation of mutations. Our model predicts that the phase transition may be induced by drug therapies that elevate the mutation rate, or by forcing mutations at particular amino acids. Applying immune pressure to any combination of killer T-cell targets cannot induce the transition, providing a rationale for why the viral protein can exist close to the error catastrophe without sustaining fatal fitness penalties due to adaptive immunity.
NASA Technical Reports Server (NTRS)
Marshall, Paul; Carts, Marty; Campbell, Art; Reed, Robert; Ladbury, Ray; Seidleck, Christina; Currie, Steve; Riggs, Pam; Fritz, Karl; Randall, Barb
2004-01-01
A viewgraph presentation that reviews recent SiGe bit error test data for different commercially available high speed SiGe BiCMOS chips that were subjected to various levels of heavy ion and proton radiation. Results for the tested chips at different operating speeds are displayed in line graphs.
DiGirolamo, Gregory J; Gonzalez, Gerardo; Smelson, David; Guevremont, Nathan; Andre, Michael I; Patnaik, Pooja O; Zaniewski, Zachary R
2017-01-01
Cue-elicited craving is a clinically important aspect of cocaine addiction directly linked to cognitive control breakdowns and relapse to cocaine-taking behavior. However, whether craving drives breakdowns in cognitive control toward cocaine cues in veterans, who experience significantly more co-occurring mood disorders, is unknown. The present study tests whether veterans have breakdowns in cognitive control because of cue-elicited craving or current anxiety or depression symptoms. Twenty-four veterans with cocaine use disorder were cue-exposed, then tested on an antisaccade task in which participants were asked to control their eye movements toward cocaine or neutral cues by looking away from the cue. The relationship among cognitive control breakdowns (as measured by eye errors), cue-induced craving (changes in self-reported craving following cocaine cue exposure), and mood measures (depression and anxiety) was investigated. Veterans made significantly more errors toward cocaine cues than neutral cues. Depression and anxiety scores, but not cue-elicited craving, were significantly associated with increased subsequent errors toward cocaine cues for veterans. Increased depression and anxiety are specifically related to more cognitive control breakdowns toward cocaine cues in veterans. Depression and anxiety must be considered further in the etiology and treatment of cocaine use disorder in veterans. Furthermore, treating depression and anxiety as well, rather than solely alleviating craving levels, may prove a more effective combined treatment option in veterans with cocaine use disorder.
1981-03-01
lots. A single store of partially processed devices may serve as a source for several different product lines. Because the manufacture of microwave...matrix, or react chem- ically with some of the semiconductor materials. In some cases these element impurities may migrate to an interface inducing... different viscosity, the background intensity varied independently of the signal, a significant error could be introduced. A more effec- tive method
NASA Technical Reports Server (NTRS)
Tasca, D. M.
1981-01-01
Single event upset phenomena are discussed, taking into account cosmic ray induced errors in IIL microprocessors and logic devices, single event upsets in NMOS microprocessors, a prediction model for bipolar RAMs in a high energy ion/proton environment, the search for neutron-induced hard errors in VLSI structures, soft errors due to protons in the radiation belt, and the use of an ion microbeam to study single event upsets in microcircuits. Basic mechanisms in materials and devices are examined, giving attention to gamma induced noise in CCD's, the annealing of MOS capacitors, an analysis of photobleaching techniques for the radiation hardening of fiber optic data links, a hardened field insulator, the simulation of radiation damage in solids, and the manufacturing of radiation resistant optical fibers. Energy deposition and dosimetry is considered along with SGEMP/IEMP, radiation effects in devices, space radiation effects and spacecraft charging, EMP/SREMP, and aspects of fabrication, testing, and hardness assurance.
Propagation of resist heating mask error to wafer level
NASA Astrophysics Data System (ADS)
Babin, S. V.; Karklin, Linard
2006-10-01
As technology is approaching 45 nm and below the IC industry is experiencing a severe product yield hit due to rapidly shrinking process windows and unavoidable manufacturing process variations. Current EDA tools are unable by their nature to deliver optimized and process-centered designs that call for 'post design' localized layout optimization DFM tools. To evaluate the impact of different manufacturing process variations on final product it is important to trace and evaluate all errors through design to manufacturing flow. Photo mask is one of the critical parts of this flow, and special attention should be paid to photo mask manufacturing process and especially to mask tight CD control. Electron beam lithography (EBL) is a major technique which is used for fabrication of high-end photo masks. During the writing process, resist heating is one of the sources for mask CD variations. Electron energy is released in the mask body mainly as heat, leading to significant temperature fluctuations in local areas. The temperature fluctuations cause changes in resist sensitivity, which in turn leads to CD variations. These CD variations depend on mask writing speed, order of exposure, pattern density and its distribution. Recent measurements revealed up to 45 nm CD variation on the mask when using ZEP resist. The resist heating problem with CAR resists is significantly smaller compared to other types of resists. This is partially due to higher resist sensitivity and the lower exposure dose required. However, there is no data yet showing CD errors on the wafer induced by CAR resist heating on the mask. This effect can be amplified by high MEEF values and should be carefully evaluated at 45nm and below technology nodes where tight CD control is required. In this paper, we simulated CD variation on the mask due to resist heating; then a mask pattern with the heating error was transferred onto the wafer. So, a CD error on the wafer was evaluated subject to only one term of the mask error budget - the resist heating CD error. In simulation of exposure using a stepper, variable MEEF was considered.
Model parameter-related optimal perturbations and their contributions to El Niño prediction errors
NASA Astrophysics Data System (ADS)
Tao, Ling-Jiang; Gao, Chuan; Zhang, Rong-Hua
2018-04-01
Errors in initial conditions and model parameters (MPs) are the main sources that limit the accuracy of ENSO predictions. In addition to exploring the initial error-induced prediction errors, model errors are equally important in determining prediction performance. In this paper, the MP-related optimal errors that can cause prominent error growth in ENSO predictions are investigated using an intermediate coupled model (ICM) and a conditional nonlinear optimal perturbation (CNOP) approach. Two MPs related to the Bjerknes feedback are considered in the CNOP analysis: one involves the SST-surface wind coupling ({α _τ } ), and the other involves the thermocline effect on the SST ({α _{Te}} ). The MP-related optimal perturbations (denoted as CNOP-P) are found uniformly positive and restrained in a small region: the {α _τ } component is mainly concentrated in the central equatorial Pacific, and the {α _{Te}} component is mainly located in the eastern cold tongue region. This kind of CNOP-P enhances the strength of the Bjerknes feedback and induces an El Niño- or La Niña-like error evolution, resulting in an El Niño-like systematic bias in this model. The CNOP-P is also found to play a role in the spring predictability barrier (SPB) for ENSO predictions. Evidently, such error growth is primarily attributed to MP errors in small areas based on the localized distribution of CNOP-P. Further sensitivity experiments firmly indicate that ENSO simulations are sensitive to the representation of SST-surface wind coupling in the central Pacific and to the thermocline effect in the eastern Pacific in the ICM. These results provide guidance and theoretical support for the future improvement in numerical models to reduce the systematic bias and SPB phenomenon in ENSO predictions.
Temporal lobe stimulation reveals anatomic distinction between auditory naming processes.
Hamberger, M J; Seidel, W T; Goodman, R R; Perrine, K; McKhann, G M
2003-05-13
Language errors induced by cortical stimulation can provide insight into function(s) supported by the area stimulated. The authors observed that some stimulation-induced errors during auditory description naming were characterized by tip-of-the-tongue responses or paraphasic errors, suggesting expressive difficulty, whereas others were qualitatively different, suggesting receptive difficulty. They hypothesized that these two response types reflected disruption at different stages of auditory verbal processing and that these "subprocesses" might be supported by anatomically distinct cortical areas. To explore the topographic distribution of error types in auditory verbal processing. Twenty-one patients requiring left temporal lobe surgery underwent preresection language mapping using direct cortical stimulation. Auditory naming was tested at temporal sites extending from 1 cm from the anterior tip to the parietal operculum. Errors were dichotomized as either "expressive" or "receptive." The topographic distribution of error types was explored. Sites associated with the two error types were topographically distinct from one another. Most receptive sites were located in the middle portion of the superior temporal gyrus (STG), whereas most expressive sites fell outside this region, scattered along lateral temporal and temporoparietal cortex. Results raise clinical questions regarding the inclusion of the STG in temporal lobe epilepsy surgery and suggest that more detailed cortical mapping might enable better prediction of postoperative language decline. From a theoretical perspective, results carry implications regarding the understanding of structure-function relations underlying temporal lobe mediation of auditory language processing.
The effect of respiratory induced density variations on non-TOF PET quantitation in the lung.
Holman, Beverley F; Cuplov, Vesna; Hutton, Brian F; Groves, Ashley M; Thielemans, Kris
2016-04-21
Accurate PET quantitation requires a matched attenuation map. Obtaining matched CT attenuation maps in the thorax is difficult due to the respiratory cycle which causes both motion and density changes. Unlike with motion, little attention has been given to the effects of density changes in the lung on PET quantitation. This work aims to explore the extent of the errors caused by pulmonary density attenuation map mismatch on dynamic and static parameter estimates. Dynamic XCAT phantoms were utilised using clinically relevant (18)F-FDG and (18)F-FMISO time activity curves for all organs within the thorax to estimate the expected parameter errors. The simulations were then validated with PET data from 5 patients suffering from idiopathic pulmonary fibrosis who underwent PET/Cine-CT. The PET data were reconstructed with three gates obtained from the Cine-CT and the average Cine-CT. The lung TACs clearly displayed differences between true and measured curves with error depending on global activity distribution at the time of measurement. The density errors from using a mismatched attenuation map were found to have a considerable impact on PET quantitative accuracy. Maximum errors due to density mismatch were found to be as high as 25% in the XCAT simulation. Differences in patient derived kinetic parameter estimates and static concentration between the extreme gates were found to be as high as 31% and 14%, respectively. Overall our results show that respiratory associated density errors in the attenuation map affect quantitation throughout the lung, not just regions near boundaries. The extent of this error is dependent on the activity distribution in the thorax and hence on the tracer and time of acquisition. Consequently there may be a significant impact on estimated kinetic parameters throughout the lung.
Fleming, Kevin K; Bandy, Carole L; Kimble, Matthew O
2010-01-01
The decision to shoot a gun engages executive control processes that can be biased by cultural stereotypes and perceived threat. The neural locus of the decision to shoot is likely to be found in the anterior cingulate cortex (ACC), where cognition and affect converge. Male military cadets at Norwich University (N=37) performed a weapon identification task in which they made rapid decisions to shoot when images of guns appeared briefly on a computer screen. Reaction times, error rates, and electroencephalogram (EEG) activity were recorded. Cadets reacted more quickly and accurately when guns were primed by images of Middle-Eastern males wearing traditional clothing. However, cadets also made more false positive errors when tools were primed by these images. Error-related negativity (ERN) was measured for each response. Deeper ERNs were found in the medial-frontal cortex following false positive responses. Cadets who made fewer errors also produced deeper ERNs, indicating stronger executive control. Pupil size was used to measure autonomic arousal related to perceived threat. Images of Middle-Eastern males in traditional clothing produced larger pupil sizes. An image of Osama bin Laden induced the largest pupil size, as would be predicted for the exemplar of Middle East terrorism. Cadets who showed greater increases in pupil size also made more false positive errors. Regression analyses were performed to evaluate predictions based on current models of perceived threat, stereotype activation, and cognitive control. Measures of pupil size (perceived threat) and ERN (cognitive control) explained significant proportions of the variance in false positive errors to Middle-Eastern males in traditional clothing, while measures of reaction time, signal detection response bias, and stimulus discriminability explained most of the remaining variance.
The effect of respiratory induced density variations on non-TOF PET quantitation in the lung
NASA Astrophysics Data System (ADS)
Holman, Beverley F.; Cuplov, Vesna; Hutton, Brian F.; Groves, Ashley M.; Thielemans, Kris
2016-04-01
Accurate PET quantitation requires a matched attenuation map. Obtaining matched CT attenuation maps in the thorax is difficult due to the respiratory cycle which causes both motion and density changes. Unlike with motion, little attention has been given to the effects of density changes in the lung on PET quantitation. This work aims to explore the extent of the errors caused by pulmonary density attenuation map mismatch on dynamic and static parameter estimates. Dynamic XCAT phantoms were utilised using clinically relevant 18F-FDG and 18F-FMISO time activity curves for all organs within the thorax to estimate the expected parameter errors. The simulations were then validated with PET data from 5 patients suffering from idiopathic pulmonary fibrosis who underwent PET/Cine-CT. The PET data were reconstructed with three gates obtained from the Cine-CT and the average Cine-CT. The lung TACs clearly displayed differences between true and measured curves with error depending on global activity distribution at the time of measurement. The density errors from using a mismatched attenuation map were found to have a considerable impact on PET quantitative accuracy. Maximum errors due to density mismatch were found to be as high as 25% in the XCAT simulation. Differences in patient derived kinetic parameter estimates and static concentration between the extreme gates were found to be as high as 31% and 14%, respectively. Overall our results show that respiratory associated density errors in the attenuation map affect quantitation throughout the lung, not just regions near boundaries. The extent of this error is dependent on the activity distribution in the thorax and hence on the tracer and time of acquisition. Consequently there may be a significant impact on estimated kinetic parameters throughout the lung.
Fleming, Kevin K.; Bandy, Carole L.; Kimble, Matthew O.
2014-01-01
The decision to shoot engages executive control processes that can be biased by cultural stereotypes and perceived threat. The neural locus of the decision to shoot is likely to be found in the anterior cingulate cortex (ACC) where cognition and affect converge. Male military cadets at Norwich University (N=37) performed a weapon identification task in which they made rapid decisions to shoot when images of guns appeared briefly on a computer screen. Reaction times, error rates, and EEG activity were recorded. Cadets reacted more quickly and accurately when guns were primed by images of middle-eastern males wearing traditional clothing. However, cadets also made more false positive errors when tools were primed by these images. Error-related negativity (ERN) was measured for each response. Deeper ERN’s were found in the medial-frontal cortex following false positive responses. Cadets who made fewer errors also produced deeper ERN’s, indicating stronger executive control. Pupil size was used to measure autonomic arousal related to perceived threat. Images of middle-eastern males in traditional clothing produced larger pupil sizes. An image of Osama bin Laden induced the largest pupil size, as would be predicted for the exemplar of Middle East terrorism. Cadets who showed greater increases in pupil size also made more false positive errors. Regression analyses were performed to evaluate predictions based on current models of perceived threat, stereotype activation, and cognitive control. Measures of pupil size (perceived threat) and ERN (cognitive control) explained significant proportions of the variance in false positive errors to middle-eastern males in traditional clothing, while measures of reaction time, signal detection response bias, and stimulus discriminability explained most of the remaining variance. PMID:19813139
Robust Linear Models for Cis-eQTL Analysis.
Rantalainen, Mattias; Lindgren, Cecilia M; Holmes, Christopher C
2015-01-01
Expression Quantitative Trait Loci (eQTL) analysis enables characterisation of functional genetic variation influencing expression levels of individual genes. In outbread populations, including humans, eQTLs are commonly analysed using the conventional linear model, adjusting for relevant covariates, assuming an allelic dosage model and a Gaussian error term. However, gene expression data generally have noise that induces heavy-tailed errors relative to the Gaussian distribution and often include atypical observations, or outliers. Such departures from modelling assumptions can lead to an increased rate of type II errors (false negatives), and to some extent also type I errors (false positives). Careful model checking can reduce the risk of type-I errors but often not type II errors, since it is generally too time-consuming to carefully check all models with a non-significant effect in large-scale and genome-wide studies. Here we propose the application of a robust linear model for eQTL analysis to reduce adverse effects of deviations from the assumption of Gaussian residuals. We present results from a simulation study as well as results from the analysis of real eQTL data sets. Our findings suggest that in many situations robust models have the potential to provide more reliable eQTL results compared to conventional linear models, particularly in respect to reducing type II errors due to non-Gaussian noise. Post-genomic data, such as that generated in genome-wide eQTL studies, are often noisy and frequently contain atypical observations. Robust statistical models have the potential to provide more reliable results and increased statistical power under non-Gaussian conditions. The results presented here suggest that robust models should be considered routinely alongside other commonly used methodologies for eQTL analysis.
Dynamic response tests of inertial and optical wind-tunnel model attitude measurement devices
NASA Technical Reports Server (NTRS)
Buehrle, R. D.; Young, C. P., Jr.; Burner, A. W.; Tripp, J. S.; Tcheng, P.; Finley, T. D.; Popernack, T. G., Jr.
1995-01-01
Results are presented for an experimental study of the response of inertial and optical wind-tunnel model attitude measurement systems in a wind-off simulated dynamic environment. This study is part of an ongoing activity at the NASA Langley Research Center to develop high accuracy, advanced model attitude measurement systems that can be used in a dynamic wind-tunnel environment. This activity was prompted by the inertial model attitude sensor response observed during high levels of model vibration which results in a model attitude measurement bias error. Significant bias errors in model attitude measurement were found for the measurement using the inertial device during wind-off dynamic testing of a model system. The amount of bias present during wind-tunnel tests will depend on the amplitudes of the model dynamic response and the modal characteristics of the model system. Correction models are presented that predict the vibration-induced bias errors to a high degree of accuracy for the vibration modes characterized in the simulated dynamic environment. The optical system results were uncorrupted by model vibration in the laboratory setup.
Design and simulation of a 800 Mbit/s data link for magnetic resonance imaging wearables.
Vogt, Christian; Buthe, Lars; Petti, Luisa; Cantarella, Giuseppe; Munzenrieder, Niko; Daus, Alwin; Troster, Gerhard
2015-08-01
This paper presents the optimization of electronic circuitry for operation in the harsh electro magnetic (EM) environment during a magnetic resonance imaging (MRI) scan. As demonstrator, a device small enough to be worn during the scan is optimized. Based on finite element method (FEM) simulations, the induced current densities due to magnetic field changes of 200 T s(-1) were reduced from 1 × 10(10) A m(-2) by one order of magnitude, predicting error-free operation of the 1.8V logic employed. The simulations were validated using a bit error rate test, which showed no bit errors during a MRI scan sequence. Therefore, neither the logic, nor the utilized 800 Mbit s(-1) low voltage differential swing (LVDS) data link of the optimized wearable device were significantly influenced by the EM interference. Next, the influence of ferro-magnetic components on the static magnetic field and consequently the image quality was simulated showing a MRI image loss with approximately 2 cm radius around a commercial integrated circuit of 1×1 cm(2). This was successively validated by a conventional MRI scan.
Spelling performance of 2nd to 5th grade students from public school.
Capellini, Simone Aparecida; Amaral, Amanda Corrêa do; Oliveira, Andrea Batista; Sampaio, Maria Nobre; Fusco, Natália; Cervera-Mérida, José Francisco; Ygual-Fernández, Amparo
2011-09-01
To characterize, compare and classify the performance of 2nd to 5th grade students from public schools according to the semiology of spelling errors. Participants were 120 students from 2nd to 5th grades of a public school in Marília (SP), Brazil, 30 students from each grade, who were divided into four groups: GI (2nd grade), GII (3rd grade), GIII (4th grade), and GIV (5th grade). The tasks of the Pro-Ortografia test were applied: collective version (writing of alphabet letters, randomized dictation of letters, words dictation, nonwords dictation, dictation with pictures, thematic writing induced by picture) and individual version (dictation of sentences, purposeful error, spelled dictation, orthographic lexical memory). Significant difference was found in the between-group comparison indicating better performance of students in every subsequent grade in most of the individual and collective version tasks. With the increase of grade level, the groups decreased the average of writing errors. The profile of spelling acquisition of the Portuguese writing system found in these public school students indicates normal writing development in this population.
Motyer, R E; Liddy, S; Torreggiani, W C; Buckley, O
2016-11-01
Voice recognition (VR) dictation of radiology reports has become the mainstay of reporting in many institutions worldwide. Despite benefit, such software is not without limitations, and transcription errors have been widely reported. Evaluate the frequency and nature of non-clinical transcription error using VR dictation software. Retrospective audit of 378 finalised radiology reports. Errors were counted and categorised by significance, error type and sub-type. Data regarding imaging modality, report length and dictation time was collected. 67 (17.72 %) reports contained ≥1 errors, with 7 (1.85 %) containing 'significant' and 9 (2.38 %) containing 'very significant' errors. A total of 90 errors were identified from the 378 reports analysed, with 74 (82.22 %) classified as 'insignificant', 7 (7.78 %) as 'significant', 9 (10 %) as 'very significant'. 68 (75.56 %) errors were 'spelling and grammar', 20 (22.22 %) 'missense' and 2 (2.22 %) 'nonsense'. 'Punctuation' error was most common sub-type, accounting for 27 errors (30 %). Complex imaging modalities had higher error rates per report and sentence. Computed tomography contained 0.040 errors per sentence compared to plain film with 0.030. Longer reports had a higher error rate, with reports >25 sentences containing an average of 1.23 errors per report compared to 0-5 sentences containing 0.09. These findings highlight the limitations of VR dictation software. While most error was deemed insignificant, there were occurrences of error with potential to alter report interpretation and patient management. Longer reports and reports on more complex imaging had higher error rates and this should be taken into account by the reporting radiologist.
Social context modulates cognitive markers in Obsessive-Compulsive Disorder.
Santamaría-García, Hernando; Soriano-Mas, Carles; Burgaleta, Miguel; Ayneto, Alba; Alonso, Pino; Menchón, José M; Cardoner, Narcis; Sebastián-Gallés, Nuria
2017-08-03
Error monitoring, cognitive control and motor inhibition control are proposed as cognitive alterations disrupted in obsessive-compulsive disorder (OCD). OCD has also been associated with an increased sensitivity to social evaluations. The effect of a social simulation over electrophysiological indices of cognitive alterations in OCD was examined. A case-control cross-sectional study measuring event-related potentials (ERP) for error monitoring (Error-Related Negativity), cognitive control (N2) and motor control (LRP) was conducted. We analyzed twenty OCD patients and twenty control participants. ERP were recorded during a social game consisting of a visual discrimination task, which was performed in the presence of a simulated superior or an inferior player. Significant social effects (different ERP amplitudes in Superior vs. Inferior player conditions) were found for OCD patients, but not for controls, in all ERP components. Performing the task against a simulated inferior player reduced abnormal ERP responses in OCD to levels observed in controls. The hierarchy-induced ERP effects were accompanied effects over reaction times in OCD patients. Social context modulates signatures of abnormal cognitive functioning in OCD, therefore experiencing a social superiority position impacts over cognitive processes in OCD such as error monitoring mechanisms. These results open the door for the research of new therapeutic choices.
Moon, J; Ota, K T; Driscoll, L L; Levitsky, D A; Strupp, B J
2008-07-01
This study was designed to further assess cognitive and affective functioning in a mouse model of Fragile X syndrome (FXS), the Fmr1(tm1Cgr) or Fmr1 "knockout" (KO) mouse. Male KO mice and wild-type littermate controls were tested on learning set and reversal learning tasks. The KO mice were not impaired in associative learning, transfer of learning, or reversal learning, based on measures of learning rate. Analyses of videotapes of the reversal learning task revealed that both groups of mice exhibited higher levels of activity and wall-climbing during the initial sessions of the task than during the final sessions, a pattern also seen for trials following an error relative to those following a correct response. Notably, the increase in both behavioral measures seen early in the task was significantly more pronounced for the KO mice than for controls, as was the error-induced increase in activity level. This pattern of effects suggests that the KO mice reacted more strongly than controls to the reversal of contingencies and pronounced drop in reinforcement rate, and to errors in general. This pattern of effects is consistent with the heightened emotional reactivity frequently described for humans with FXS. (c) 2008 Wiley Periodicals, Inc.
Loganathan, Sundareswaran; Rathinasamy, Sheeladevi
2016-01-01
Noise stress has different effects on memory and novelty and the link between them with an electroencephalogram (EEG) has not yet been reported. To find the effect of sub-acute noise stress on the memory and novelty along with EEG and neurotransmitter changes. Eight-arm maze (EAM) and Y-maze to analyze the memory and novelty by novel object test. Four groups of rats were used: Control, control treated with Scoparia dulcis extract, noise exposed, and noise exposed which received Scoparia extract. The results showed no marked difference observed between control and control treated with Scoparia extract on EAM, Y-maze, novel object test, and EEG in both prefrontal and occipital region, however, noise stress exposed rats showed significant increase in the reference memory and working memory error in EAM and latency delay, triad errors in Y-maze, and prefrontal and occipital EEG frequency rate with the corresponding increase in plasma corticosterone and epinephrine, and significant reduction in the novelty test, and significant reduction in the novelty test, amplitude of prefrontal, occipital EEG, and acetylcholine. These noise stress induced changes in EAM, Y-maze, novel object test, and neurotransmitters were significantly prevented when treated with Scoparia extract and these changes may be due to the normalizing action of Scoparia extract on the brain, which altered due to noise stress. Noise stress exposure causes EEG, behavior, and neurotransmitter alteration in the frontoparietal and occipital regions mainly involved in planning and recognition memoryOnly the noise stress exposed animals showed the significant alteration in the EEG, behavior, and neurotransmittersHowever, these noise stress induced changes in EEG behavior and neurotransmitters were significantly prevented when treated with Scoparia extractThese changes may be due to the normalizing action of Scoparia dulcis (adoptogen) on the brain which altered by noise stress. Abbreviations used: EEG: Electroencephalogram, dB: Decibel, EPI: Epinephrine, ACH: Acetylcholine, EAM: Eight-arm maze.
Loganathan, Sundareswaran; Rathinasamy, Sheeladevi
2016-01-01
Background: Noise stress has different effects on memory and novelty and the link between them with an electroencephalogram (EEG) has not yet been reported. Objective: To find the effect of sub-acute noise stress on the memory and novelty along with EEG and neurotransmitter changes. Materials and Methods: Eight-arm maze (EAM) and Y-maze to analyze the memory and novelty by novel object test. Four groups of rats were used: Control, control treated with Scoparia dulcis extract, noise exposed, and noise exposed which received Scoparia extract. Results: The results showed no marked difference observed between control and control treated with Scoparia extract on EAM, Y-maze, novel object test, and EEG in both prefrontal and occipital region, however, noise stress exposed rats showed significant increase in the reference memory and working memory error in EAM and latency delay, triad errors in Y-maze, and prefrontal and occipital EEG frequency rate with the corresponding increase in plasma corticosterone and epinephrine, and significant reduction in the novelty test, and significant reduction in the novelty test, amplitude of prefrontal, occipital EEG, and acetylcholine. Conclusion: These noise stress induced changes in EAM, Y-maze, novel object test, and neurotransmitters were significantly prevented when treated with Scoparia extract and these changes may be due to the normalizing action of Scoparia extract on the brain, which altered due to noise stress. SUMMARY Noise stress exposure causes EEG, behavior, and neurotransmitter alteration in the frontoparietal and occipital regions mainly involved in planning and recognition memoryOnly the noise stress exposed animals showed the significant alteration in the EEG, behavior, and neurotransmittersHowever, these noise stress induced changes in EEG behavior and neurotransmitters were significantly prevented when treated with Scoparia extractThese changes may be due to the normalizing action of Scoparia dulcis (adoptogen) on the brain which altered by noise stress. Abbreviations used: EEG: Electroencephalogram, dB: Decibel, EPI: Epinephrine, ACH: Acetylcholine, EAM: Eight-arm maze PMID:27041862
PCNA mono-ubiquitination and activation of translesion DNA polymerases by DNA polymerase {alpha}.
Suzuki, Motoshi; Niimi, Atsuko; Limsirichaikul, Siripan; Tomida, Shuta; Miao Huang, Qin; Izuta, Shunji; Usukura, Jiro; Itoh, Yasutomo; Hishida, Takashi; Akashi, Tomohiro; Nakagawa, Yoshiyuki; Kikuchi, Akihiko; Pavlov, Youri; Murate, Takashi; Takahashi, Takashi
2009-07-01
Translesion DNA synthesis (TLS) involves PCNA mono-ubiquitination and TLS DNA polymerases (pols). Recent evidence has shown that the mono-ubiquitination is induced not only by DNA damage but also by other factors that induce stalling of the DNA replication fork. We studied the effect of spontaneous DNA replication errors on PCNA mono-ubiquitination and TLS induction. In the pol1L868F strain, which expressed an error-prone pol alpha, PCNA was spontaneously mono-ubiquitinated. Pol alpha L868F had a rate-limiting step at the extension from mismatched primer termini. Electron microscopic observation showed the accumulation of a single-stranded region at the DNA replication fork in yeast cells. For pol alpha errors, pol zeta participated in a generation of +1 frameshifts. Furthermore, in the pol1L868F strain, UV-induced mutations were lower than in the wild-type and a pol delta mutant strain (pol3-5DV), and deletion of the RAD30 gene (pol eta) suppressed this defect. These data suggest that nucleotide misincorporation by pol alpha induces exposure of single-stranded DNA, PCNA mono-ubiquitination and activates TLS pols.
Menelaou, Evdokia; Paul, Latoya T.; Perera, Surangi N.; Svoboda, Kurt R.
2015-01-01
Nicotine exposure during embryonic stages of development can affect many neurodevelopmental processes. In the developing zebrafish, exposure to nicotine was reported to cause axonal pathfinding errors in the later born secondary motoneurons (SMN). These alterations in SMN axon morphology coincided with muscle degeneration at high nicotine concentrations (15–30µM). Previous work showed that the paralytic mutant zebrafish known as sofa potato, exhibited nicotine-induced effects onto SMN axons at these high concentrations but in the absence of any muscle deficits, indicating that pathfinding errors could occur independent of muscle effects. In this study, we used varying concentrations of nicotine at different developmental windows of exposure to specifically isolate its effects onto subpopulations of motoneuron axons. We found that nicotine exposure can affect SMN axon morphology in a dose-dependent manner. At low concentrations of nicotine, SMN axons exhibited pathfinding errors, in the absence of any nicotine-induced muscle abnormalities. Moreover, the nicotine exposure paradigms used affected the 3 subpopulations of SMN axons differently, but the dorsal projecting SMN axons were primarily affected. We then identified morphologically distinct pathfinding errors that best described the nicotine-induced effects on dorsal projecting SMN axons. To test whether SMN pathfinding was potentially influenced by alterations in the early born primary motoneuron (PMN), we performed dual labeling studies, where both PMN and SMN axons were simultaneously labeled with antibodies. We show that only a subset of the SMN axon pathfinding errors coincided with abnormal PMN axonal targeting in nicotine-exposed zebrafish. We conclude that nicotine exposure can exert differential effects depending on the levels of nicotine and developmental exposure window. PMID:25668718
NASA Astrophysics Data System (ADS)
Rojo, Pilar; Royo, Santiago; Caum, Jesus; Ramírez, Jorge; Madariaga, Ines
2015-02-01
Peripheral refraction, the refractive error present outside the main direction of gaze, has lately attracted interest due to its alleged relationship with the progression of myopia. The ray tracing procedures involved in its calculation need to follow an approach different from those used in conventional ophthalmic lens design, where refractive errors are compensated only in the main direction of gaze. We present a methodology for the evaluation of the peripheral refractive error in ophthalmic lenses, adapting the conventional generalized ray tracing approach to the requirements of the evaluation of peripheral refraction. The nodal point of the eye and a retinal conjugate surface will be used to evaluate the three-dimensional distribution of refractive error around the fovea. The proposed approach enables us to calculate the three-dimensional peripheral refraction induced by any ophthalmic lens at any direction of gaze and to personalize the lens design to the requirements of the user. The complete evaluation process for a given user prescribed with a -5.76D ophthalmic lens for foveal vision is detailed, and comparative results obtained when the geometry of the lens is modified and when the central refractive error is over- or undercorrected. The methodology is also applied for an emmetropic eye to show its application for refractive errors other than myopia.
Hoogeveen, Suzanne; Schjoedt, Uffe; van Elk, Michiel
2018-06-19
This study examines the effects of expected transcranial stimulation on the error(-related) negativity (Ne or ERN) and the sense of agency in participants who perform a cognitive control task. Placebo transcranial direct current stimulation was used to elicit expectations of transcranially induced cognitive improvement or impairment. The improvement/impairment manipulation affected both the Ne/ERN and the sense of agency (i.e., whether participants attributed errors to oneself or the brain stimulation device): Expected improvement increased the ERN in response to errors compared with both impairment and control conditions. Expected impairment made participants falsely attribute errors to the transcranial stimulation. This decrease in sense of agency was correlated with a reduced ERN amplitude. These results show that expectations about transcranial stimulation impact users' neural response to self-generated errors and the attribution of responsibility-especially when actions lead to negative outcomes. We discuss our findings in relation to predictive processing theory according to which the effect of prior expectations on the ERN reflects the brain's attempt to generate predictive models of incoming information. By demonstrating that induced expectations about transcranial stimulation can have effects at a neural level, that is, beyond mere demand characteristics, our findings highlight the potential for placebo brain stimulation as a promising tool for research.
NASA Technical Reports Server (NTRS)
Berman, P. A.
1973-01-01
In order to improve reliability and the useful lifetime of solar cell arrays for space use, a program was undertaken to develop radiation-hardened lithium-doped silicon solar cells. These cells were shown to be significantly more resistant to degradation by ionized particles than the presently used n-p nonlithium-doped silicon solar cells. The results of various analyses performed to develop a more complete understanding of the physics of the interaction among lithium, silicon, oxygen, and radiation-induced defects are presented. A discussion is given of those portions of the previous model of radiation damage annealing which were found to be in error and those portions which were upheld by these extensive investigations.
Overlay improvement by exposure map based mask registration optimization
NASA Astrophysics Data System (ADS)
Shi, Irene; Guo, Eric; Chen, Ming; Lu, Max; Li, Gordon; Li, Rivan; Tian, Eric
2015-03-01
Along with the increased miniaturization of semiconductor electronic devices, the design rules of advanced semiconductor devices shrink dramatically. [1] One of the main challenges of lithography step is the layer-to-layer overlay control. Furthermore, DPT (Double Patterning Technology) has been adapted for the advanced technology node like 28nm and 14nm, corresponding overlay budget becomes even tighter. [2][3] After the in-die mask registration (pattern placement) measurement is introduced, with the model analysis of a KLA SOV (sources of variation) tool, it's observed that registration difference between masks is a significant error source of wafer layer-to-layer overlay at 28nm process. [4][5] Mask registration optimization would highly improve wafer overlay performance accordingly. It was reported that a laser based registration control (RegC) process could be applied after the pattern generation or after pellicle mounting and allowed fine tuning of the mask registration. [6] In this paper we propose a novel method of mask registration correction, which can be applied before mask writing based on mask exposure map, considering the factors of mask chip layout, writing sequence, and pattern density distribution. Our experiment data show if pattern density on the mask keeps at a low level, in-die mask registration residue error in 3sigma could be always under 5nm whatever blank type and related writer POSCOR (position correction) file was applied; it proves random error induced by material or equipment would occupy relatively fixed error budget as an error source of mask registration. On the real production, comparing the mask registration difference through critical production layers, it could be revealed that registration residue error of line space layers with higher pattern density is always much larger than the one of contact hole layers with lower pattern density. Additionally, the mask registration difference between layers with similar pattern density could also achieve under 5nm performance. We assume mask registration excluding random error is mostly induced by charge accumulation during mask writing, which may be calculated from surrounding exposed pattern density. Multi-loading test mask registration result shows that with x direction writing sequence, mask registration behavior in x direction is mainly related to sequence direction, but mask registration in y direction would be highly impacted by pattern density distribution map. It proves part of mask registration error is due to charge issue from nearby environment. If exposure sequence is chip by chip for normal multi chip layout case, mask registration of both x and y direction would be impacted analogously, which has also been proved by real data. Therefore, we try to set up a simple model to predict the mask registration error based on mask exposure map, and correct it with the given POSCOR (position correction) file for advanced mask writing if needed.
Lack of dependence on resonant error field of locked mode island size in ohmic plasmas in DIII-D
Haye, R. J. La; Paz-Soldan, C.; Strait, E. J.
2015-01-23
DIII-D experiments show that fully penetrated resonant n=1 error field locked modes in Ohmic plasmas with safety factor q 95≳3 grow to similar large disruptive size, independent of resonant error field correction. Relatively small resonant (m/n=2/1) static error fields are shielded in Ohmic plasmas by the natural rotation at the electron diamagnetic drift frequency. However, the drag from error fields can lower rotation such that a bifurcation results, from nearly complete shielding to full penetration, i.e., to a driven locked mode island that can induce disruption.
Truong, Trong-Kha; Guidon, Arnaud
2014-01-01
Purpose To develop and compare three novel reconstruction methods designed to inherently correct for motion-induced phase errors in multi-shot spiral diffusion tensor imaging (DTI) without requiring a variable-density spiral trajectory or a navigator echo. Theory and Methods The first method simply averages magnitude images reconstructed with sensitivity encoding (SENSE) from each shot, whereas the second and third methods rely on SENSE to estimate the motion-induced phase error for each shot, and subsequently use either a direct phase subtraction or an iterative conjugate gradient (CG) algorithm, respectively, to correct for the resulting artifacts. Numerical simulations and in vivo experiments on healthy volunteers were performed to assess the performance of these methods. Results The first two methods suffer from a low signal-to-noise ratio (SNR) or from residual artifacts in the reconstructed diffusion-weighted images and fractional anisotropy maps. In contrast, the third method provides high-quality, high-resolution DTI results, revealing fine anatomical details such as a radial diffusion anisotropy in cortical gray matter. Conclusion The proposed SENSE+CG method can inherently and effectively correct for phase errors, signal loss, and aliasing artifacts caused by both rigid and nonrigid motion in multi-shot spiral DTI, without increasing the scan time or reducing the SNR. PMID:23450457
Emergence of DNA Polymerase ε Antimutators That Escape Error-Induced Extinction in Yeast
Williams, Lindsey N.; Herr, Alan J.; Preston, Bradley D.
2013-01-01
DNA polymerases (Pols) ε and δ perform the bulk of yeast leading- and lagging-strand DNA synthesis. Both Pols possess intrinsic proofreading exonucleases that edit errors during polymerization. Rare errors that elude proofreading are extended into duplex DNA and excised by the mismatch repair (MMR) system. Strains that lack Pol proofreading or MMR exhibit a 10- to 100-fold increase in spontaneous mutation rate (mutator phenotype), and inactivation of both Pol δ proofreading (pol3-01) and MMR is lethal due to replication error-induced extinction (EEX). It is unclear whether a similar synthetic lethal relationship exists between defects in Pol ε proofreading (pol2-4) and MMR. Using a plasmid-shuffling strategy in haploid Saccharomyces cerevisiae, we observed synthetic lethality of pol2-4 with alleles that completely abrogate MMR (msh2Δ, mlh1Δ, msh3Δ msh6Δ, or pms1Δ mlh3Δ) but not with partial MMR loss (msh3Δ, msh6Δ, pms1Δ, or mlh3Δ), indicating that high levels of unrepaired Pol ε errors drive extinction. However, variants that escape this error-induced extinction (eex mutants) frequently emerged. Five percent of pol2-4 msh2Δ eex mutants encoded second-site changes in Pol ε that reduced the pol2-4 mutator phenotype between 3- and 23-fold. The remaining eex alleles were extragenic to pol2-4. The locations of antimutator amino-acid changes in Pol ε and their effects on mutation spectra suggest multiple mechanisms of mutator suppression. Our data indicate that unrepaired leading- and lagging-strand polymerase errors drive extinction within a few cell divisions and suggest that there are polymerase-specific pathways of mutator suppression. The prevalence of suppressors extragenic to the Pol ε gene suggests that factors in addition to proofreading and MMR influence leading-strand DNA replication fidelity. PMID:23307893
SU-E-J-45: The Correlation Between CBCT Flat Panel Misalignment and 3D Image Guidance Accuracy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kenton, O; Valdes, G; Yin, L
Purpose To simulate the impact of CBCT flat panel misalignment on the image quality, the calculated correction vectors in 3D image guided proton therapy and to determine if these calibration errors can be caught in our QA process. Methods The X-ray source and detector geometrical calibration (flexmap) file of the CBCT system in the AdaPTinsight software (IBA proton therapy) was edited to induce known changes in the rotational and translational calibrations of the imaging panel. Translations of up to ±10 mm in the x, y and z directions (see supplemental) and rotational errors of up to ±3° were induced. Themore » calibration files were then used to reconstruct the CBCT image of a pancreatic patient and CatPhan phantom. Correction vectors were calculated for the patient using the software’s auto match system and compared to baseline values. The CatPhan CBCT images were used for quantitative evaluation of image quality for each type of induced error. Results Translations of 1 to 3 mm in the x and y calibration resulted in corresponding correction vector errors of equal magnitude. Similar 10mm shifts were seen in the y-direction; however, in the x-direction, the image quality was too degraded for a match. These translational errors can be identified through differences in isocenter from orthogonal kV images taken during routine QA. Errors in the z-direction had no effect on the correction vector and image quality.Rotations of the imaging panel calibration resulted in corresponding correction vector rotations of the patient images. These rotations also resulted in degraded image quality which can be identified through quantitative image quality metrics. Conclusion Misalignment of CBCT geometry can lead to incorrect translational and rotational patient correction vectors. These errors can be identified through QA of the imaging isocenter as compared to orthogonal images combined with monitoring of CBCT image quality.« less
NASA Astrophysics Data System (ADS)
Sinkin, Oleg V.; Grigoryan, Vladimir S.; Menyuk, Curtis R.
2006-12-01
We introduce a fully deterministic, computationally efficient method for characterizing the effect of nonlinearity in optical fiber transmission systems that utilize wavelength-division multiplexing and return-to-zero modulation. The method accurately accounts for bit-pattern-dependent nonlinear distortion due to collision-induced timing jitter and for amplifier noise. We apply this method to calculate the error probability as a function of channel spacing in a prototypical multichannel return-to-zero undersea system.
Mbah, Chamberlain; De Ruyck, Kim; De Schrijver, Silke; De Sutter, Charlotte; Schiettecatte, Kimberly; Monten, Chris; Paelinck, Leen; De Neve, Wilfried; Thierens, Hubert; West, Catharine; Amorim, Gustavo; Thas, Olivier; Veldeman, Liv
2018-05-01
Evaluation of patient characteristics inducing toxicity in breast radiotherapy, using simultaneous modeling of multiple endpoints. In 269 early-stage breast cancer patients treated with whole-breast irradiation (WBI) after breast-conserving surgery, toxicity was scored, based on five dichotomized endpoints. Five logistic regression models were fitted, one for each endpoint and the effect sizes of all variables were estimated using maximum likelihood (MLE). The MLEs are improved with James-Stein estimates (JSEs). The method combines all the MLEs, obtained for the same variable but from different endpoints. Misclassification errors were computed using MLE- and JSE-based prediction models. For associations, p-values from the sum of squares of MLEs were compared with p-values from the Standardized Total Average Toxicity (STAT) Score. With JSEs, 19 highest ranked variables were predictive of the five different endpoints. Important variables increasing radiation-induced toxicity were chemotherapy, age, SATB2 rs2881208 SNP and nodal irradiation. Treatment position (prone position) was most protective and ranked eighth. Overall, the misclassification errors were 45% and 34% for the MLE- and JSE-based models, respectively. p-Values from the sum of squares of MLEs and p-values from STAT score led to very similar conclusions, except for the variables nodal irradiation and treatment position, for which STAT p-values suggested an association with radiosensitivity, whereas p-values from the sum of squares indicated no association. Breast volume was ranked as the most significant variable in both strategies. The James-Stein estimator was used for selecting variables that are predictive for multiple toxicity endpoints. With this estimator, 19 variables were predictive for all toxicities of which four were significantly associated with overall radiosensitivity. JSEs led to almost 25% reduction in the misclassification error rate compared to conventional MLEs. Finally, patient characteristics that are associated with radiosensitivity were identified without explicitly quantifying radiosensitivity.
Shannon, Harlan E; Love, Patrick L
2007-02-01
Patients with epilepsy can have impaired cognitive abilities. Antiepileptic drugs (AEDs) may contribute to the cognitive deficits observed in patients with epilepsy, and have been shown to induce cognitive impairments in healthy individuals. However, there are few systematic data on the effects of AEDs on specific cognitive domains. We have previously demonstrated that a number of AEDs can impair working memory and attention. The purpose of the present study was to evaluate the effects of AEDs on learning as measured by a repeated acquisition of response sequences task in nonepileptic rats. The GABA-related AEDs phenobarbital and chlordiazepoxide significantly disrupted performance by shifting the learning curve to the right and increasing errors, whereas tiagabine and valproate did not. The sodium channel blockers carbamazepine and phenytoin suppressed responding at higher doses, whereas lamotrigine shifted the learning curve to the right and increased errors, and topiramate was without significant effect. Levetiracetam also shifted the learning curve to the right and increased errors. The disruptions produced by triazolam, chlordiazepoxide, lamotrigine, and levetiracetam were qualitatively similar to the effects of the muscarinic cholinergic receptor antagonist scopolamine. The present results indicate that AEDs can impair learning, but there are differences among AEDs in the magnitude of the disruption in nonepileptic rats, with drugs that enhance GABA receptor function and some that block sodium channels producing the most consistent impairment of learning.
NASA Technical Reports Server (NTRS)
Noble, Viveca K.
1993-01-01
There are various elements such as radio frequency interference (RFI) which may induce errors in data being transmitted via a satellite communication link. When a transmission is affected by interference or other error-causing elements, the transmitted data becomes indecipherable. It becomes necessary to implement techniques to recover from these disturbances. The objective of this research is to develop software which simulates error control circuits and evaluate the performance of these modules in various bit error rate environments. The results of the evaluation provide the engineer with information which helps determine the optimal error control scheme. The Consultative Committee for Space Data Systems (CCSDS) recommends the use of Reed-Solomon (RS) and convolutional encoders and Viterbi and RS decoders for error correction. The use of forward error correction techniques greatly reduces the received signal to noise needed for a certain desired bit error rate. The use of concatenated coding, e.g. inner convolutional code and outer RS code, provides even greater coding gain. The 16-bit cyclic redundancy check (CRC) code is recommended by CCSDS for error detection.
Mitigating leakage errors due to cavity modes in a superconducting quantum computer
NASA Astrophysics Data System (ADS)
McConkey, T. G.; Béjanin, J. H.; Earnest, C. T.; McRae, C. R. H.; Pagel, Z.; Rinehart, J. R.; Mariantoni, M.
2018-07-01
A practical quantum computer requires quantum bit (qubit) operations with low error probabilities in extensible architectures. We study a packaging method that makes it possible to address hundreds of superconducting qubits by means of coaxial Pogo pins. A qubit chip is housed in a superconducting box, where both box and chip dimensions lead to unwanted modes that can interfere with qubit operations. We analyze these interference effects in the context of qubit coherent leakage and qubit decoherence induced by damped modes. We propose two methods, half-wave fencing and antinode pinning, to mitigate the resulting errors by detuning the resonance frequency of the modes from the qubit frequency. We perform electromagnetic field simulations indicating that the resonance frequency of the modes increases with the number of installed pins and can be engineered to be significantly higher than the highest qubit frequency. We estimate that the error probabilities and decoherence rates due to suitably shifted modes in realistic scenarios can be up to two orders of magnitude lower than the state-of-the-art superconducting qubit error and decoherence rates. Our methods can be extended to different types of packages that do not rely on Pogo pins. Conductive bump bonds, for example, can serve the same purpose in qubit architectures based on flip chip technology. Metalized vias, instead, can be used to mitigate modes due to the increasing size of the dielectric substrate on which qubit arrays are patterned.
Inducible DNA-repair systems in yeast: competition for lesions.
Mitchel, R E; Morrison, D P
1987-03-01
DNA lesions may be recognized and repaired by more than one DNA-repair process. If two repair systems with different error frequencies have overlapping lesion specificity and one or both is inducible, the resulting variable competition for the lesions can change the biological consequences of these lesions. This concept was demonstrated by observing mutation in yeast cells (Saccharomyces cerevisiae) exposed to combinations of mutagens under conditions which influenced the induction of error-free recombinational repair or error-prone repair. Total mutation frequency was reduced in a manner proportional to the dose of 60Co-gamma- or 254 nm UV radiation delivered prior to or subsequent to an MNNG exposure. Suppression was greater per unit radiation dose in cells gamma-irradiated in O2 as compared to N2. A rad3 (excision-repair) mutant gave results similar to wild-type but mutation in a rad52 (rec-) mutant exposed to MNNG was not suppressed by radiation. Protein-synthesis inhibition with heat shock or cycloheximide indicated that it was the mutation due to MNNG and not that due to radiation which had changed. These results indicate that MNNG lesions are recognized by both the recombinational repair system and the inducible error-prone system, but that gamma-radiation induction of error-free recombinational repair resulted in increased competition for the lesions, thereby reducing mutation. Similarly, gamma-radiation exposure resulted in a radiation dose-dependent reduction in mutation due to MNU, EMS, ENU and 8-MOP + UVA, but no reduction in mutation due to MMS. These results suggest that the number of mutational MMS lesions recognizable by the recombinational repair system must be very small relative to those produced by the other agents. MNNG induction of the inducible error-prone systems however, did not alter mutation frequencies due to ENU or MMS exposure but, in contrast to radiation, increased the mutagenic effectiveness of EMS. These experiments demonstrate that in this lower eukaryote, mutagen exposure does not necessarily result in a fixed risk of mutation, but that the risk can be markedly influenced by a variety of external stimuli including heat shock or exposure to other mutagens.
Thomas, S; Schaeffel, F
2000-01-01
It is not clear whether emmetropization is confined to spherical refractive errors, or whether astiqmatic errors are also corrected via visual feedback. Experimental results from the animal model of the chicken are equivocal since compensation of imposed astimatic defocus was found in some but not all studies. Astigmatism could only be compensated by changes in the geometry of the cornea or lens. One has tested whether astigmatic spectacle lenses induce astigmatic accommodation as a possible first step of long-lasting compensation. Thirty-five chickens were treated with cylinder lenses (+3/0D or -3/0D) for 5 h. Refractions were determined at 1.38 m distance without cycloplegia in hand-held chicks before attaching the lenses, with the lenses on (0 h), and after 3 and 5 h, and after removal of the lenses. Spheres (S), cylinders (C) and axes (A) were determined using infrared photoretinocopy in three axes (the 'PowerRefractor', equipped with a 135 mm lens). (1) The performance of the 'PowerRefractor' was tested in the chickens with trial lenses and gave correct refractions. (2) Astigmatic trial lenses induced refractive errors as expected from their powers in the case of +3/0D lenses: (S) +3.26 +/- 0.93D, (C) -3.45 +/- 0.87D). In the case of -3/0D lenses, slightly more hyperopic spheres were induced (refractions (S) +4.5 +/- 0.48D) but the cylinders were still as expected (-3.25 +/- 0.49D). The axes of astigmatism were correctly reproduced, since rotating the lenses changed the axes of the induced cylinders as expected. (3) Neither after 3 nor after 5 h of lens wear were there significant changes in the axes or the magnitude of astigmatism. Directly after removal of the lens, the refractions did not differ from their start-up values (with +3/0D lenses: (S) +3.31 +/- 1.05D vs. +3.22 +/- 0.76D, (C) -1.19 +/- 1.77D vs. -0.65 +/- 0.94D, (A) 96 +/- 49 vs. 113 +/- 45 deg; with -3/0D lenses: (S) 2.63 +/- 1.12D vs. 2.97 +/- 0.94D, (C) -1.11 +/- 1.15D vs. -0.53 +/- 0.56D, (A) 78 +/- 24 vs. 131 +/- 35 deg). The most intuitive mechanism for compensation of astigmatic refractive errors, astigmatic accommodation, could not be demonstrated in chickens. In light of this finding, it seems unlikely that a visually controlled mechanism is operating during development to reduced astigmatism by changing corneal or lenticular growth.
Neale, Chris; Madill, Chris; Rauscher, Sarah; Pomès, Régis
2013-08-13
All molecular dynamics simulations are susceptible to sampling errors, which degrade the accuracy and precision of observed values. The statistical convergence of simulations containing atomistic lipid bilayers is limited by the slow relaxation of the lipid phase, which can exceed hundreds of nanoseconds. These long conformational autocorrelation times are exacerbated in the presence of charged solutes, which can induce significant distortions of the bilayer structure. Such long relaxation times represent hidden barriers that induce systematic sampling errors in simulations of solute insertion. To identify optimal methods for enhancing sampling efficiency, we quantitatively evaluate convergence rates using generalized ensemble sampling algorithms in calculations of the potential of mean force for the insertion of the ionic side chain analog of arginine in a lipid bilayer. Umbrella sampling (US) is used to restrain solute insertion depth along the bilayer normal, the order parameter commonly used in simulations of molecular solutes in lipid bilayers. When US simulations are modified to conduct random walks along the bilayer normal using a Hamiltonian exchange algorithm, systematic sampling errors are eliminated more rapidly and the rate of statistical convergence of the standard free energy of binding of the solute to the lipid bilayer is increased 3-fold. We compute the ratio of the replica flux transmitted across a defined region of the order parameter to the replica flux that entered that region in Hamiltonian exchange simulations. We show that this quantity, the transmission factor, identifies sampling barriers in degrees of freedom orthogonal to the order parameter. The transmission factor is used to estimate the depth-dependent conformational autocorrelation times of the simulation system, some of which exceed the simulation time, and thereby identify solute insertion depths that are prone to systematic sampling errors and estimate the lower bound of the amount of sampling that is required to resolve these sampling errors. Finally, we extend our simulations and verify that the conformational autocorrelation times estimated by the transmission factor accurately predict correlation times that exceed the simulation time scale-something that, to our knowledge, has never before been achieved.
Mochida, Takemi; Gomi, Hiroaki; Kashino, Makio
2010-11-08
There has been plentiful evidence of kinesthetically induced rapid compensation for unanticipated perturbation in speech articulatory movements. However, the role of auditory information in stabilizing articulation has been little studied except for the control of voice fundamental frequency, voice amplitude and vowel formant frequencies. Although the influence of auditory information on the articulatory control process is evident in unintended speech errors caused by delayed auditory feedback, the direct and immediate effect of auditory alteration on the movements of articulators has not been clarified. This work examined whether temporal changes in the auditory feedback of bilabial plosives immediately affects the subsequent lip movement. We conducted experiments with an auditory feedback alteration system that enabled us to replace or block speech sounds in real time. Participants were asked to produce the syllable /pa/ repeatedly at a constant rate. During the repetition, normal auditory feedback was interrupted, and one of three pre-recorded syllables /pa/, /Φa/, or /pi/, spoken by the same participant, was presented once at a different timing from the anticipated production onset, while no feedback was presented for subsequent repetitions. Comparisons of the labial distance trajectories under altered and normal feedback conditions indicated that the movement quickened during the short period immediately after the alteration onset, when /pa/ was presented 50 ms before the expected timing. Such change was not significant under other feedback conditions we tested. The earlier articulation rapidly induced by the progressive auditory input suggests that a compensatory mechanism helps to maintain a constant speech rate by detecting errors between the internally predicted and actually provided auditory information associated with self movement. The timing- and context-dependent effects of feedback alteration suggest that the sensory error detection works in a temporally asymmetric window where acoustic features of the syllable to be produced may be coded.
Dopamine reward prediction error coding.
Schultz, Wolfram
2016-03-01
Reward prediction errors consist of the differences between received and predicted rewards. They are crucial for basic forms of learning about rewards and make us strive for more rewards-an evolutionary beneficial trait. Most dopamine neurons in the midbrain of humans, monkeys, and rodents signal a reward prediction error; they are activated by more reward than predicted (positive prediction error), remain at baseline activity for fully predicted rewards, and show depressed activity with less reward than predicted (negative prediction error). The dopamine signal increases nonlinearly with reward value and codes formal economic utility. Drugs of addiction generate, hijack, and amplify the dopamine reward signal and induce exaggerated, uncontrolled dopamine effects on neuronal plasticity. The striatum, amygdala, and frontal cortex also show reward prediction error coding, but only in subpopulations of neurons. Thus, the important concept of reward prediction errors is implemented in neuronal hardware.
Investigating error structure of shuttle radar topography mission elevation data product
NASA Astrophysics Data System (ADS)
Becek, Kazimierz
2008-08-01
An attempt was made to experimentally assess the instrumental component of error of the C-band SRTM (SRTM). This was achieved by comparing elevation data of 302 runways from airports all over the world with the shuttle radar topography mission data product (SRTM). It was found that the rms of the instrumental error is about +/-1.55 m. Modeling of the remaining SRTM error sources, including terrain relief and pixel size, shows that downsampling from 30 m to 90 m (1 to 3 arc-sec pixels) worsened SRTM vertical accuracy threefold. It is suspected that the proximity of large metallic objects is a source of large SRTM errors. The achieved error estimates allow a pixel-based accuracy assessment of the SRTM elevation data product to be constructed. Vegetation-induced errors were not considered in this work.
Dopamine reward prediction error coding
Schultz, Wolfram
2016-01-01
Reward prediction errors consist of the differences between received and predicted rewards. They are crucial for basic forms of learning about rewards and make us strive for more rewards—an evolutionary beneficial trait. Most dopamine neurons in the midbrain of humans, monkeys, and rodents signal a reward prediction error; they are activated by more reward than predicted (positive prediction error), remain at baseline activity for fully predicted rewards, and show depressed activity with less reward than predicted (negative prediction error). The dopamine signal increases nonlinearly with reward value and codes formal economic utility. Drugs of addiction generate, hijack, and amplify the dopamine reward signal and induce exaggerated, uncontrolled dopamine effects on neuronal plasticity. The striatum, amygdala, and frontal cortex also show reward prediction error coding, but only in subpopulations of neurons. Thus, the important concept of reward prediction errors is implemented in neuronal hardware. PMID:27069377
Temperature-Dependence of Air-Broadened Line Widths and Shifts in the nu3 Band of Ozone
NASA Technical Reports Server (NTRS)
Smith, Mary A. H.; Rinsland, Curtis P.; Devi, V. Malathy; Benner, D. Chris; Cox, A. M.
2006-01-01
The 9.6-micron bands of O3 are used by many remote-sensing experiments for retrievals of terrestrial atmospheric ozone concentration profiles. Line parameter errors can contribute significantly to the total errors in these retrievals, particularly for nadir-viewing. The McMath-Pierce Fourier transform spectrometer at the National Solar Observatory on Kitt Peak was used to record numerous high-resolution infrared absorption spectra of O3 broadened by various gases at temperatures between 160 and 300 K. Over 30 spectra were analyzed simultaneously using a multispectrum nonlinear least squares fitting technique to determine Lorentz air-broadening and pressure-induced shift coefficients along with their temperature dependences for selected transitions in the 3 fundamental band of (16)O3. We compare the present results with other measurements reported in the literature and with the ozone parameters on the 2000 and 2004 editions of the HITRAN database.
Explicitly solvable complex Chebyshev approximation problems related to sine polynomials
NASA Technical Reports Server (NTRS)
Freund, Roland
1989-01-01
Explicitly solvable real Chebyshev approximation problems on the unit interval are typically characterized by simple error curves. A similar principle is presented for complex approximation problems with error curves induced by sine polynomials. As an application, some new explicit formulae for complex best approximations are derived.
Lexical and Semantic Binding in Verbal Short-Term Memory
ERIC Educational Resources Information Center
Jefferies, Elizabeth; Frankish, Clive R.; Ralph, Matthew A. Lambon
2006-01-01
Semantic dementia patients make numerous phoneme migration errors in their immediate serial recall of poorly comprehended words. In this study, similar errors were induced in the word recall of healthy participants by presenting unpredictable mixed lists of words and nonwords. This technique revealed that lexicality, word frequency, imageability,…
Inducing Speech Errors in Dysarthria Using Tongue Twisters
ERIC Educational Resources Information Center
Kember, Heather; Connaghan, Kathryn; Patel, Rupal
2017-01-01
Although tongue twisters have been widely use to study speech production in healthy speakers, few studies have employed this methodology for individuals with speech impairment. The present study compared tongue twister errors produced by adults with dysarthria and age-matched healthy controls. Eight speakers (four female, four male; mean age =…
Dynamic regulation of heart rate during acute hypotension: new insight into baroreflex function
NASA Technical Reports Server (NTRS)
Zhang, R.; Behbehani, K.; Crandall, C. G.; Zuckerman, J. H.; Levine, B. D.; Blomqvist, C. G. (Principal Investigator)
2001-01-01
To examine the dynamic properties of baroreflex function, we measured beat-to-beat changes in arterial blood pressure (ABP) and heart rate (HR) during acute hypotension induced by thigh cuff deflation in 10 healthy subjects under supine resting conditions and during progressive lower body negative pressure (LBNP). The quantitative, temporal relationship between ABP and HR was fitted by a second-order autoregressive (AR) model. The frequency response was evaluated by transfer function analysis. Results: HR changes during acute hypotension appear to be controlled by an ABP error signal between baseline and induced hypotension. The quantitative relationship between changes in ABP and HR is characterized by a second-order AR model with a pure time delay of 0.75 s containing low-pass filter properties. During LBNP, the change in HR/change in ABP during induced hypotension significantly decreased, as did the numerator coefficients of the AR model and transfer function gain. Conclusions: 1) Beat-to-beat HR responses to dynamic changes in ABP may be controlled by an error signal rather than directional changes in pressure, suggesting a "set point" mechanism in short-term ABP control. 2) The quantitative relationship between dynamic changes in ABP and HR can be described by a second-order AR model with a pure time delay. 3) The ability of the baroreflex to evoke a HR response to transient changes in pressure was reduced during LBNP, which was due primarily to a reduction of the static gain of the baroreflex.
Behroozmand, Roozbeh; Karvelis, Laura; Liu, Hanjun; Larson, Charles R.
2009-01-01
Objective The present study investigated whether self-vocalization enhances auditory neural responsiveness to voice pitch feedback perturbation and how this vocalization-induced neural modulation can be affected by the extent of the feedback deviation. Method Event related potentials (ERPs) were recorded in 15 subjects in response to +100, +200 and +500 cents pitch-shifted voice auditory feedback during active vocalization and passive listening to the playback of the self-produced vocalizations. Result The amplitude of the evoked P1 (latency: 73.51 ms) and P2 (latency: 199.55 ms) ERP components in response to feedback perturbation were significantly larger during vocalization than listening. The difference between P2 peak amplitudes during vocalization vs. listening was shown to be significantly larger for +100 than +500 cents stimulus. Conclusion Results indicate that the human auditory cortex is more responsive to voice F0 feedback perturbations during vocalization than passive listening. Greater vocalization-induced enhancement of the auditory responsiveness to smaller feedback perturbations may imply that the audio-vocal system detects and corrects for errors in vocal production that closely match the expected vocal output. Significance Findings of this study support previous suggestions regarding the enhanced auditory sensitivity to feedback alterations during self-vocalization, which may serve the purpose of feedback-based monitoring of one’s voice. PMID:19520602
Competence in Streptococcus pneumoniae is regulated by the rate of ribosomal decoding errors.
Stevens, Kathleen E; Chang, Diana; Zwack, Erin E; Sebert, Michael E
2011-01-01
Competence for genetic transformation in Streptococcus pneumoniae develops in response to accumulation of a secreted peptide pheromone and was one of the initial examples of bacterial quorum sensing. Activation of this signaling system induces not only expression of the proteins required for transformation but also the production of cellular chaperones and proteases. We have shown here that activity of this pathway is sensitively responsive to changes in the accuracy of protein synthesis that are triggered by either mutations in ribosomal proteins or exposure to antibiotics. Increasing the error rate during ribosomal decoding promoted competence, while reducing the error rate below the baseline level repressed the development of both spontaneous and antibiotic-induced competence. This pattern of regulation was promoted by the bacterial HtrA serine protease. Analysis of strains with the htrA (S234A) catalytic site mutation showed that the proteolytic activity of HtrA selectively repressed competence when translational fidelity was high but not when accuracy was low. These findings redefine the pneumococcal competence pathway as a response to errors during protein synthesis. This response has the capacity to address the immediate challenge of misfolded proteins through production of chaperones and proteases and may also be able to address, through genetic exchange, upstream coding errors that cause intrinsic protein folding defects. The competence pathway may thereby represent a strategy for dealing with lesions that impair proper protein coding and for maintaining the coding integrity of the genome. The signaling pathway that governs competence in the human respiratory tract pathogen Streptococcus pneumoniae regulates both genetic transformation and the production of cellular chaperones and proteases. The current study shows that this pathway is sensitively controlled in response to changes in the accuracy of protein synthesis. Increasing the error rate during ribosomal decoding induced competence, while decreasing the error rate repressed competence. This pattern of regulation was promoted by the HtrA protease, which selectively repressed competence when translational fidelity was high but not when accuracy was low. Our findings demonstrate that this organism is able to monitor the accuracy of information used for protein biosynthesis and suggest that errors trigger a response addressing both the immediate challenge of misfolded proteins and, through genetic exchange, upstream coding errors that may underlie protein folding defects. This pathway may represent an evolutionary strategy for maintaining the coding integrity of the genome.
A radiation tolerant Data link board for the ATLAS Tile Cal upgrade
NASA Astrophysics Data System (ADS)
Åkerstedt, H.; Bohm, C.; Muschter, S.; Silverstein, S.; Valdes, E.
2016-01-01
This paper describes the latest, full-functionality revision of the high-speed data link board developed for the Phase-2 upgrade of ATLAS hadronic Tile Calorimeter. The link board design is highly redundant, with digital functionality implemented in two Xilinx Kintex-7 FPGAs, and two Molex QSFP+ electro-optic modules with uplinks run at 10 Gbps. The FPGAs are remotely configured through two radiation-hard CERN GBTx deserialisers (GBTx), which also provide the LHC-synchronous system clock. The redundant design eliminates virtually all single-point error modes, and a combination of triple-mode redundancy (TMR), internal and external scrubbing will provide adequate protection against radiation-induced errors. The small portion of the FPGA design that cannot be protected by TMR will be the dominant source of radiation-induced errors, even if that area is small.
Damage Initiation in Two-Dimensional, Woven, Carbon-Carbon Composites
1988-12-01
biaxial stress interaction were themselves a function of the applied biaxial stress ratio and thus the error in measuring F12 depended on F12. To find the...the supported directions. Discretizing the model will tend to induce error in the computed nodal displacements when compared to an exact continuum...solution, however, for an increasing number of elements in the structural model, the net error should converge to zero (3:94). The inherent flexibility in
NASA Astrophysics Data System (ADS)
Zhou, Yanru; Zhao, Yuxiang; Tian, Hui; Zhang, Dengwei; Huang, Tengchao; Miao, Lijun; Shu, Xiaowu; Che, Shuangliang; Liu, Cheng
2016-12-01
In an axial magnetic field (AMF), which is vertical to the plane of the fiber coil, a polarization-maintaining fiber optic gyro (PM-FOG) appears as an axial magnetic error. This error is linearly related to the intensity of an AMF, the radius of the fiber coil, and the light wavelength, and also influenced by the distribution of fiber twist. When a PM-FOG is manufactured completely, this error only appears a linear correlation with the AMF. A real-time compensation model is established to eliminate the error, and the experimental results show that the axial magnetic error of the PM-FOG is decreased from 5.83 to 0.09 deg/h in 12G AMF with 18-dB suppression.
NASA Astrophysics Data System (ADS)
Zhao, Fei; Zhang, Chi; Yang, Guilin; Chen, Chinyin
2016-12-01
This paper presents an online estimation method of cutting error by analyzing of internal sensor readings. The internal sensors of numerical control (NC) machine tool are selected to avoid installation problem. The estimation mathematic model of cutting error was proposed to compute the relative position of cutting point and tool center point (TCP) from internal sensor readings based on cutting theory of gear. In order to verify the effectiveness of the proposed model, it was simulated and experimented in gear generating grinding process. The cutting error of gear was estimated and the factors which induce cutting error were analyzed. The simulation and experiments verify that the proposed approach is an efficient way to estimate the cutting error of work-piece during machining process.
6-Hydroxy dopamine does not affect lens-induced refractive errors but suppresses deprivation myopia.
Schaeffel, F; Hagel, G; Bartmann, M; Kohler, K; Zrenner, E
1994-01-01
Degradation of the retinal image by translucent occluders during postnatal development induces axial myopia in chickens, tree shrews and monkeys. Local visual deprivation produces myopia even in local regions of the eye and neither accommodation nor intact connection between the eye and the brain are necessary. Therefore, it is an important question whether a similar local-retinal pathway translating visual information into growth or stretch signals to the underlying sclera is acting to emmetropize the growing eye. It is not known until now whether occluder deprivation triggers similar eye growth (or scleral stretch) mechanisms that are also responsible for visual guidance of normal refractive development. We here report that, in chickens, 6-hydroxy dopamine suppresses deprivation-induced myopia but has no effect on the magnitude of changes in axial eye elongation that are induced by spectacle lenses. The result suggests that, in chickens with normal accommodation, two pharmacologically different feedback loops may be responsible for deprivation myopia and lens-induced refractive errors.
Calculation of cosmic ray induced single event upsets: Program CRUP (Cosmic Ray Upset Program)
NASA Astrophysics Data System (ADS)
Shapiro, P.
1983-09-01
This report documents PROGRAM CRUP, COSMIC RAY UPSET PROGRAM. The computer program calculates cosmic ray induced single-event error rates in microelectronic circuits exposed to several representative cosmic-ray environments.
Durg, Sharanbasappa; Veerapur, Veeresh P; Thippeswamy, B S; Ahamed, Syed Mansoor
2015-01-01
Śilājatu (Shilajit; SJ) is claimed in traditional Indian medical practice to be useful in the treatment of nervous disorders, epilepsy and as antistress. To investigate whether SJ possesses antiepileptic and antipsychotic activities in rodents. Isonicotinyl hydrazine (INH), pentylenetetrazole (PTZ), apomorphine, phenytoin, diazepam, haloperidol and other chemicals of analytical grade were procured from standard companies. The antiepileptic activity of SJ was assessed using maximal electro shock (MES)-induced seizures in rats, INH and PTZ-induced seizures in mice. The antipsychotic effect of SJ was evaluated using apomorphine-induced climbing and stereotyped behaviours respectively, in mice and rats. SJ (25 and 50 mg/kg, p.o.) was given orally once daily for 15 days in all the rodent models. On the test day, SJ was administered 1 h prior to electric shock or chemical inducers (INH/PTZ/apomorphine) in experimental animals; the animals were then observed for different phases of seizures and psychotic behaviours. In addition, gamma-aminobutyric acid (GABA) content in the brain of rats and mice was estimated in seizure models. The data were expressed as mean ± standard error of mean. Statistical comparisons were performed by one-way ANOVA followed by Tukey's post-test using Graph Pad Prism version 5.0, USA. A P < 0.05 was considered significant. SJ pretreatment significantly inhibited the seizures induced by MES, INH and PTZ in a dose dependent manner. Further, SJ augmented brain GABA levels to normal, decreased by INH and PTZ in mice brain. SJ pretreatment also significantly inhibited the climbing and stereotyped behaviours induced by apomorphine. The present data seems to confirm the antiepileptic activity of SJ which may be because of enhancing the GABAergic system. The antipsychotic activity observed may be due to anti-dopaminergic and/or GABA-mimetic actions.
Piñero, David P.; Camps, Vicente J.; Ramón, María L.; Mateo, Verónica; Pérez-Cambrodí, Rafael J.
2015-01-01
AIM To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). RESULTS PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors. PMID:26085998
Piñero, David P; Camps, Vicente J; Ramón, María L; Mateo, Verónica; Pérez-Cambrodí, Rafael J
2015-01-01
To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.
Mismatch Negativity Encoding of Prediction Errors Predicts S-ketamine-Induced Cognitive Impairments
Schmidt, André; Bachmann, Rosilla; Kometer, Michael; Csomor, Philipp A; Stephan, Klaas E; Seifritz, Erich; Vollenweider, Franz X
2012-01-01
Psychotomimetics like the N-methyl--aspartate receptor (NMDAR) antagonist ketamine and the 5-hydroxytryptamine2A receptor (5-HT2AR) agonist psilocybin induce psychotic symptoms in healthy volunteers that resemble those of schizophrenia. Recent theories of psychosis posit that aberrant encoding of prediction errors (PE) may underlie the expression of psychotic symptoms. This study used a roving mismatch negativity (MMN) paradigm to investigate whether the encoding of PE is affected by pharmacological manipulation of NMDAR or 5-HT2AR, and whether the encoding of PE under placebo can be used to predict drug-induced symptoms. Using a double-blind within-subject placebo-controlled design, S-ketamine and psilocybin, respectively, were administrated to two groups of healthy subjects. Psychological alterations were assessed using a revised version of the Altered States of Consciousness (ASC-R) questionnaire. As an index of PE, we computed changes in MMN amplitudes as a function of the number of preceding standards (MMN memory trace effect) during a roving paradigm. S-ketamine, but not psilocybin, disrupted PE processing as expressed by a frontally disrupted MMN memory trace effect. Although both drugs produced positive-like symptoms, the extent of PE processing under placebo only correlated significantly with the severity of cognitive impairments induced by S-ketamine. Our results suggest that the NMDAR, but not the 5-HT2AR system, is implicated in PE processing during the MMN paradigm, and that aberrant PE signaling may contribute to the formation of cognitive impairments. The assessment of the MMN memory trace in schizophrenia may allow detecting early phases of the illness and might also serve to assess the efficacy of novel pharmacological treatments, in particular of cognitive impairments. PMID:22030715
Simulation of a long-term aquifer test conducted near the Rio Grande, Albuquerque, New Mexico
McAda, Douglas P.
2001-01-01
A long-term aquifer test was conducted near the Rio Grande in Albuquerque during January and February 1995 using 22 wells and piezometers at nine sites, with the City of Albuquerque Griegos 1 production well as the pumped well. Griegos 1 discharge averaged about 2,330 gallons per minute for 54.4 days. A three-dimensional finite-difference ground-water-flow model was used to estimate aquifer properties in the vicinity of the Griegos well field and the amount of infiltration induced into the aquifer system from the Rio Grande and riverside drains as a result of pumping during the test. The model was initially calibrated by trial-and-error adjustments of the aquifer properties. The model was recalibrated using a nonlinear least-squares regression technique. The aquifer system in the area includes the middle Tertiary to Quaternary Santa Fe Group and post-Santa Fe Group valley- and basin-fill deposits of the Albuquerque Basin. The Rio Grande and adjacent riverside drains are in hydraulic connection with the aquifer system. The hydraulic-conductivity values of the upper part of the Santa Fe Group resulting from the model calibrated by trial and error varied by zone in the model and ranged from 12 to 33 feet per day. The hydraulic conductivity of the inner-valley alluvium was 45 feet per day. The vertical to horizontal anisotropy ratio was 1:140. Specific storage was 4 x 10-6 per foot of aquifer thickness, and specific yield was 0.15 (dimensionless). The sum of squared errors between the observed and simulated drawdowns was 130 feet squared. Not all aquifer properties could be estimated using nonlinear regression because of model insensitivity to some aquifer properties at observation locations. Hydraulic conductivity of the inner-valley alluvium, middle part of the Santa Fe Group, and riverbed and riverside-drain bed and specific yield had low sensitivity values and therefore could not be estimated. Of the properties estimated, hydraulic conductivity of the upper part of the Santa Fe Group was estimated to be 12 feet per day, the vertical to horizontal anisotropy ratio was estimated to be 1:82, and specific storage was estimated to be 1.2 x 10-6 per foot of aquifer thickness. The overall sum of squared errors between the observed and simulated drawdowns was 87 feet squared, a significant improvement over the model calibrated by trial and error. At the end of aquifer-test pumping, induced infiltration from the Rio Grande and riverside drains was simulated to be 13 percent of the total amount of water pumped. The remainder was water removed from aquifer storage. After pumping stopped, induced infiltration continued to replenish aquifer storage. Simulations estimated that 5 years after pumping began (about 4.85 years after pumping stopped), 58 to 72 percent of the total amount of water pumped was replenished by induced infiltration from the Rio Grande surface-water system.
Working memory load impairs the evaluation of behavioral errors in the medial frontal cortex.
Maier, Martin E; Steinhauser, Marco
2017-10-01
Early error monitoring in the medial frontal cortex enables error detection and the evaluation of error significance, which helps prioritize adaptive control. This ability has been assumed to be independent from central capacity, a limited pool of resources assumed to be involved in cognitive control. The present study investigated whether error evaluation depends on central capacity by measuring the error-related negativity (Ne/ERN) in a flanker paradigm while working memory load was varied on two levels. We used a four-choice flanker paradigm in which participants had to classify targets while ignoring flankers. Errors could be due to responding either to the flankers (flanker errors) or to none of the stimulus elements (nonflanker errors). With low load, the Ne/ERN was larger for flanker errors than for nonflanker errors-an effect that has previously been interpreted as reflecting differential significance of these error types. With high load, no such effect of error type on the Ne/ERN was observable. Our findings suggest that working memory load does not impair the generation of an Ne/ERN per se but rather impairs the evaluation of error significance. They demonstrate that error monitoring is composed of capacity-dependent and capacity-independent mechanisms. © 2017 Society for Psychophysiological Research.
NASA Astrophysics Data System (ADS)
Ikeura, Takuro; Nozaki, Takayuki; Shiota, Yoichi; Yamamoto, Tatsuya; Imamura, Hiroshi; Kubota, Hitoshi; Fukushima, Akio; Suzuki, Yoshishige; Yuasa, Shinji
2018-04-01
Using macro-spin modeling, we studied the reduction in the write error rate (WER) of voltage-induced dynamic magnetization switching by enhancing the effective thermal stability of the free layer using a voltage-controlled magnetic anisotropy change. Marked reductions in WER can be achieved by introducing reverse bias voltage pulses both before and after the write pulse. This procedure suppresses the thermal fluctuations of magnetization in the initial and final states. The proposed reverse bias method can offer a new way of improving the writing stability of voltage-driven spintronic devices.
NASA Astrophysics Data System (ADS)
Chen, R. M.; Diggins, Z. J.; Mahatme, N. N.; Wang, L.; Zhang, E. X.; Chen, Y. P.; Zhang, H.; Liu, Y. N.; Narasimham, B.; Witulski, A. F.; Bhuva, B. L.; Fleetwood, D. M.
2017-08-01
The single-event sensitivity of bulk 40-nm sequential circuits is investigated as a function of temperature and supply voltage. An overall increase in SEU cross section versus temperature is observed at relatively high supply voltages. However, at low supply voltages, there is a threshold temperature beyond which the SEU cross section decreases with further increases in temperature. Single-event transient induced errors in flip-flops also increase versus temperature at relatively high supply voltages and are more sensitive to temperature variation than those caused by single-event upsets.
Using warnings to reduce categorical false memories in younger and older adults.
Carmichael, Anna M; Gutchess, Angela H
2016-07-01
Warnings about memory errors can reduce their incidence, although past work has largely focused on associative memory errors. The current study sought to explore whether warnings could be tailored to specifically reduce false recall of categorical information in both younger and older populations. Before encoding word pairs designed to induce categorical false memories, half of the younger and older participants were warned to avoid committing these types of memory errors. Older adults who received a warning committed fewer categorical memory errors, as well as other types of semantic memory errors, than those who did not receive a warning. In contrast, young adults' memory errors did not differ for the warning versus no-warning groups. Our findings provide evidence for the effectiveness of warnings at reducing categorical memory errors in older adults, perhaps by supporting source monitoring, reduction in reliance on gist traces, or through effective metacognitive strategies.
Space charge enhanced plasma gradient effects on satellite electric field measurements
NASA Technical Reports Server (NTRS)
Diebold, Dan; Hershkowitz, Noah; Dekock, J.; Intrator, T.; Hsieh, M-K.
1991-01-01
It has been recognized that plasma gradients can cause error in magnetospheric electric field measurements made by double probes. Space charge enhanced Plasma Gradient Induced Error (PGIE) is discussed in general terms, presenting the results of a laboratory experiment designed to demonstrate this error, and deriving a simple expression that quantifies this error. Experimental conditions were not identical to magnetospheric conditions, although efforts were made to insure the relevant physics applied to both cases. The experimental data demonstrate some of the possible errors in electric field measurements made by strongly emitting probes due to space charge effects in the presence of plasma gradients. Probe errors in space and laboratory conditions are discussed, as well as experimental error. In the final section, theoretical aspects are examined and an expression is derived for the maximum steady state space charge enhanced PGIE taken by two identical current biased probes.
Guanfacine ameliorates hypobaric hypoxia induced spatial working memory deficits.
Kauser, H; Sahu, S; Kumar, S; Panjwani, U
2014-01-17
Hypobaric hypoxia (HH) observed at high altitude causes mild cognitive impairment specifically affecting attention and working memory. Adrenergic dysregulation and neuronal damage in prefrontal cortex (PFC) has been implicated in hypoxia induced memory deficits. Optimal stimulation of alpha 2A adrenergic receptor in PFC facilitates the spatial working memory (SWM) under the conditions of adrenergic dysregulation. Therefore the present study was designed to test the efficacy of alpha 2A adrenergic agonist, Guanfacine (GFC), to restore HH induced SWM deficits and PFC neuronal damage. The rats were exposed to chronic HH equivalent to 25,000ft for 7days in an animal decompression chamber and received daily treatment of GFC at a dose of 1mg/kg body weight via the intramuscular route during the period of exposure. The cognitive performance was assessed by Delayed Alternation Task (DAT) using T-Maze and PFC neuronal damage was studied by apoptotic and neurodegenerative markers. Percentage of correct choice decreased significantly while perseverative errors showed a significant increase after 7days HH exposure, GFC significantly ameliorated the SWM deficits and perseveration. There was a marked and significant increase in chromatin condensation, DNA fragmentation, neuronal pyknosis and fluoro Jade positive cells in layer II of the medial PFC in hypoxia exposed group, administration of GFC significantly reduced the magnitude of these changes. Modulation of adrenergic mechanisms by GFC may serve as an effective countermeasure in amelioration of prefrontal deficits and neurodegenerative changes during HH. © 2013.
Thompson, Sam
2013-01-01
Objective. To explore the influences of discrete positive and negative emotions on cooperation in the context of a social dilemma game. Design. Two controlled studies were undertaken. In Study 1, 69 participants were randomly assigned to an essay emotion manipulation task designed to induce either guilt, joy or no strong emotion. In Study 2, 95 participants were randomly assigned to one of the same three tasks, and the impact of emotional condition on cooperation was explored using a repeated Prisoner’s Dilemma Game. Results. Study 1 established that the manipulation task was successful in inducing the specified emotions. The analysis from Study 2 revealed no significant main effects for emotions, in contrast to previous research. However, there was a significant effect for participants’ pre-existing tendency to cooperate (social value orientation; SVO). Conclusion. Methodological explanations for the result are explored, including the possible impact of trial-and-error strategies, different cooperation games and endogenous vs exogenous emotions. PMID:24432196
Kjell, Oscar N E; Thompson, Sam
2013-12-19
Objective. To explore the influences of discrete positive and negative emotions on cooperation in the context of a social dilemma game. Design. Two controlled studies were undertaken. In Study 1, 69 participants were randomly assigned to an essay emotion manipulation task designed to induce either guilt, joy or no strong emotion. In Study 2, 95 participants were randomly assigned to one of the same three tasks, and the impact of emotional condition on cooperation was explored using a repeated Prisoner's Dilemma Game. Results. Study 1 established that the manipulation task was successful in inducing the specified emotions. The analysis from Study 2 revealed no significant main effects for emotions, in contrast to previous research. However, there was a significant effect for participants' pre-existing tendency to cooperate (social value orientation; SVO). Conclusion. Methodological explanations for the result are explored, including the possible impact of trial-and-error strategies, different cooperation games and endogenous vs exogenous emotions.
NASA Technical Reports Server (NTRS)
Massey, J. L.
1976-01-01
The very low error probability obtained with long error-correcting codes results in a very small number of observed errors in simulation studies of practical size and renders the usual confidence interval techniques inapplicable to the observed error probability. A natural extension of the notion of a 'confidence interval' is made and applied to such determinations of error probability by simulation. An example is included to show the surprisingly great significance of as few as two decoding errors in a very large number of decoding trials.
ERIC Educational Resources Information Center
Taylor, Matthew A.; Skourides, Andreas; Alvero, Alicia M.
2012-01-01
Interval recording procedures are used by persons who collect data through observation to estimate the cumulative occurrence and nonoccurrence of behavior/events. Although interval recording procedures can increase the efficiency of observational data collection, they can also induce error from the observer. In the present study, 50 observers were…
Quantum error correction of continuous-variable states against Gaussian noise
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ralph, T. C.
2011-08-15
We describe a continuous-variable error correction protocol that can correct the Gaussian noise induced by linear loss on Gaussian states. The protocol can be implemented using linear optics and photon counting. We explore the theoretical bounds of the protocol as well as the expected performance given current knowledge and technology.
A regret-induced status-quo bias
Nicolle, A.; Fleming, S.M.; Bach, D.R.; Driver, J.; Dolan, R. J.
2011-01-01
A suboptimal bias towards accepting the ‘status-quo’ option in decision-making is well established behaviorally, but the underlying neural mechanisms are less clear. Behavioral evidence suggests the emotion of regret is higher when errors arise from rejection rather than acceptance of a status-quo option. Such asymmetry in the genesis of regret might drive the status-quo bias on subsequent decisions, if indeed erroneous status-quo rejections have a greater neuronal impact than erroneous status-quo acceptances. To test this, we acquired human fMRI data during a difficult perceptual decision task that incorporated a trial-to-trial intrinsic status-quo option, with explicit signaling of outcomes (error or correct). Behaviorally, experienced regret was higher after an erroneous status-quo rejection compared to acceptance. Anterior insula and medial prefrontal cortex showed increased BOLD signal after such status-quo rejection errors. In line with our hypothesis, a similar pattern of signal change predicted acceptance of the status-quo on a subsequent trial. Thus, our data link a regret-induced status-quo bias to error-related activity on the preceding trial. PMID:21368043
Foyet, Harquin Simplice; Asongalem, Acha Emmanuel; Oben, Eyong Kenneth; Cioanca, Oana; Hancianu, Monica; Hritcu, Lucian
2016-10-01
Vitellaria paradoxa C.F. Gaertn (Sapotaceae) is a perennial three which naturally grows in the northern part of Cameroon. It has been traditionally used in the Cameroonian folk medicine for treating inflammation and pain. In the present study, we evaluate the possible anti-amnesic and antioxidative effects of the methanolic extract of V. paradoxa stem bark in an Alzheimer's disease (AD) rat model of scopolamine. Rats received a single injection of scopolamine (1.5 mg/kg) before behavioral testing and were treated with the methanolic extract (25 and 50 mg/kg), daily, for eight continuous days. Also, the antioxidant activity in the hippocampus was assessed using the total content of reduced glutathione and malondialdehyde levels. The scopolamine-treated rats exhibited the following: decrease of exploratory time and discrimination index within the novel object recognition test, decrease of spontaneous alternations percentage within Y-maze task, and increase of working memory errors, reference memory errors, and time taken to consume all five baits within radial arm-maze task. Administration of the methanolic extract significantly improved these parameters, suggesting positive effects on memory formation processes and antioxidant potential. Our results suggest that the methanolic extract ameliorates scopolamine-induced memory impairment by attenuation of the oxidative stress in the rat hippocampus.
Pauné, J; Queiros, A; Quevedo, L; Neves, H; Lopes-Ferreira, D; González-Méijome, J M
2014-12-01
To evaluate the performance of two experimental contact lenses (CL) designed to induce relative peripheral myopic defocus in myopic eyes. Ten right eyes of 10 subjects were fitted with three different CL: a soft experimental lens (ExpSCL), a rigid gas permeable experimental lens (ExpRGP) and a standard RGP lens made of the same material (StdRGP). Central and peripheral refraction was measured using a Grand Seiko open-field autorefractometer across the central 60° of the horizontal visual field. Ocular aberrations were measured with a Hartman-Shack aberrometer, and monocular contrast sensitivity function (CSF) was measured with a VCTS6500 without and with the three contact lenses. Both experimental lenses were able to increase significantly the relative peripheral myopic defocus up to -0.50 D in the nasal field and -1.00 D in the temporal field (p<0.05). The ExpRGP induced a significantly higher myopic defocus in the temporal field compared to the ExpSCL. ExpSCL induced significantly lower levels of Spherical-like HOA than ExpRGP for the 5mm pupil size (p<0.05). Both experimental lenses kept CSF within normal limits without any statistically significant change from baseline (p>0.05). RGP lens design seems to be more effective to induce a significant myopic change in the relative peripheral refractive error. Both lenses preserve a good visual performance. The worsened optical quality observed in ExpRGP was due to an increased coma-like and spherical-like HOA. However, no impact on the visual quality as measured by CSF was observed. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Optimizer convergence and local minima errors and their clinical importance
NASA Astrophysics Data System (ADS)
Jeraj, Robert; Wu, Chuan; Mackie, Thomas R.
2003-09-01
Two of the errors common in the inverse treatment planning optimization have been investigated. The first error is the optimizer convergence error, which appears because of non-perfect convergence to the global or local solution, usually caused by a non-zero stopping criterion. The second error is the local minima error, which occurs when the objective function is not convex and/or the feasible solution space is not convex. The magnitude of the errors, their relative importance in comparison to other errors as well as their clinical significance in terms of tumour control probability (TCP) and normal tissue complication probability (NTCP) were investigated. Two inherently different optimizers, a stochastic simulated annealing and deterministic gradient method were compared on a clinical example. It was found that for typical optimization the optimizer convergence errors are rather small, especially compared to other convergence errors, e.g., convergence errors due to inaccuracy of the current dose calculation algorithms. This indicates that stopping criteria could often be relaxed leading into optimization speed-ups. The local minima errors were also found to be relatively small and typically in the range of the dose calculation convergence errors. Even for the cases where significantly higher objective function scores were obtained the local minima errors were not significantly higher. Clinical evaluation of the optimizer convergence error showed good correlation between the convergence of the clinical TCP or NTCP measures and convergence of the physical dose distribution. On the other hand, the local minima errors resulted in significantly different TCP or NTCP values (up to a factor of 2) indicating clinical importance of the local minima produced by physical optimization.
Optimizer convergence and local minima errors and their clinical importance.
Jeraj, Robert; Wu, Chuan; Mackie, Thomas R
2003-09-07
Two of the errors common in the inverse treatment planning optimization have been investigated. The first error is the optimizer convergence error, which appears because of non-perfect convergence to the global or local solution, usually caused by a non-zero stopping criterion. The second error is the local minima error, which occurs when the objective function is not convex and/or the feasible solution space is not convex. The magnitude of the errors, their relative importance in comparison to other errors as well as their clinical significance in terms of tumour control probability (TCP) and normal tissue complication probability (NTCP) were investigated. Two inherently different optimizers, a stochastic simulated annealing and deterministic gradient method were compared on a clinical example. It was found that for typical optimization the optimizer convergence errors are rather small, especially compared to other convergence errors, e.g., convergence errors due to inaccuracy of the current dose calculation algorithms. This indicates that stopping criteria could often be relaxed leading into optimization speed-ups. The local minima errors were also found to be relatively small and typically in the range of the dose calculation convergence errors. Even for the cases where significantly higher objective function scores were obtained the local minima errors were not significantly higher. Clinical evaluation of the optimizer convergence error showed good correlation between the convergence of the clinical TCP or NTCP measures and convergence of the physical dose distribution. On the other hand, the local minima errors resulted in significantly different TCP or NTCP values (up to a factor of 2) indicating clinical importance of the local minima produced by physical optimization.
Protective effect of rutin on cognitive impairment caused by phenytoin
Dubey, Shagun; Ganeshpurkar, Aditya; Bansal, Divya; Dubey, Nazneen
2015-01-01
Objective: To study the effect of the co-administration of phenytoin (PHT) and rutin in comparison with PHT and piracetam (PIM) on seizure control, cognitive, and motor functions in mice. Materials and Methods: Increasing current electroshock seizure (ICES) test was used to evaluate the effect of the co-administration of PHT and PIM on convulsions. Cognitive functions in mice were assessed by a spontaneous alternation in behavior on a plus maze while motor functions were screened using rolling roller apparatus and by counting the number of arms entries on a plus maze. Brain acetyl-cholinesterase (AChE) activity was also estimated. Statistical Analysis: The expression of data was done as mean ± standard error of the mean. The normally distributed data were subjected to one-way ANOVA followed by Dunnett's test. P < 0.05 was considered significant. Results: The study showed that rutin when co-administered with PHT, significantly reversed PHT-induced reduction in spontaneous alternation without altering the efficacy of PHT against ICES, in both acute and chronic studies. Further, it also reversed PHT-induced increase in AChE activity. Conclusion: Rutin alleviated the PHT-induced cognitive impairment without compromising its antiepileptic efficacy. PMID:26729954
Suitability of Smartphone Inertial Sensors for Real-Time Biofeedback Applications.
Kos, Anton; Tomažič, Sašo; Umek, Anton
2016-02-27
This article studies the suitability of smartphones with built-in inertial sensors for biofeedback applications. Biofeedback systems use various sensors to measure body functions and parameters. These sensor data are analyzed, and the results are communicated back to the user, who then tries to act on the feedback signals. Smartphone inertial sensors can be used to capture body movements in biomechanical biofeedback systems. These sensors exhibit various inaccuracies that induce significant angular and positional errors. We studied deterministic and random errors of smartphone accelerometers and gyroscopes, primarily focusing on their biases. Based on extensive measurements, we determined accelerometer and gyroscope noise models and bias variation ranges. Then, we compiled a table of predicted positional and angular errors under various biofeedback system operation conditions. We suggest several bias compensation options that are suitable for various examples of use in real-time biofeedback applications. Measurements within the developed experimental biofeedback application show that under certain conditions, even uncompensated sensors can be used for real-time biofeedback. For general use, especially for more demanding biofeedback applications, sensor biases should be compensated. We are convinced that real-time biofeedback systems based on smartphone inertial sensors are applicable to many similar examples in sports, healthcare, and other areas.
Suitability of Smartphone Inertial Sensors for Real-Time Biofeedback Applications
Kos, Anton; Tomažič, Sašo; Umek, Anton
2016-01-01
This article studies the suitability of smartphones with built-in inertial sensors for biofeedback applications. Biofeedback systems use various sensors to measure body functions and parameters. These sensor data are analyzed, and the results are communicated back to the user, who then tries to act on the feedback signals. Smartphone inertial sensors can be used to capture body movements in biomechanical biofeedback systems. These sensors exhibit various inaccuracies that induce significant angular and positional errors. We studied deterministic and random errors of smartphone accelerometers and gyroscopes, primarily focusing on their biases. Based on extensive measurements, we determined accelerometer and gyroscope noise models and bias variation ranges. Then, we compiled a table of predicted positional and angular errors under various biofeedback system operation conditions. We suggest several bias compensation options that are suitable for various examples of use in real-time biofeedback applications. Measurements within the developed experimental biofeedback application show that under certain conditions, even uncompensated sensors can be used for real-time biofeedback. For general use, especially for more demanding biofeedback applications, sensor biases should be compensated. We are convinced that real-time biofeedback systems based on smartphone inertial sensors are applicable to many similar examples in sports, healthcare, and other areas. PMID:26927125
Boundary identification and error analysis of shocked material images
NASA Astrophysics Data System (ADS)
Hock, Margaret; Howard, Marylesa; Cooper, Leora; Meehan, Bernard; Nelson, Keith
2017-06-01
To compute quantities such as pressure and velocity from laser-induced shock waves propagating through materials, high-speed images are captured and analyzed. Shock images typically display high noise and spatially-varying intensities, causing conventional analysis techniques to have difficulty identifying boundaries in the images without making significant assumptions about the data. We present a novel machine learning algorithm that efficiently segments, or partitions, images with high noise and spatially-varying intensities, and provides error maps that describe a level of uncertainty in the partitioning. The user trains the algorithm by providing locations of known materials within the image but no assumptions are made on the geometries in the image. The error maps are used to provide lower and upper bounds on quantities of interest, such as velocity and pressure, once boundaries have been identified and propagated through equations of state. This algorithm will be demonstrated on images of shock waves with noise and aberrations to quantify properties of the wave as it progresses. DOE/NV/25946-3126 This work was done by National Security Technologies, LLC, under Contract No. DE- AC52-06NA25946 with the U.S. Department of Energy and supported by the SDRD Program.
Improved estimation of anomalous diffusion exponents in single-particle tracking experiments
NASA Astrophysics Data System (ADS)
Kepten, Eldad; Bronshtein, Irena; Garini, Yuval
2013-05-01
The mean square displacement is a central tool in the analysis of single-particle tracking experiments, shedding light on various biophysical phenomena. Frequently, parameters are extracted by performing time averages on single-particle trajectories followed by ensemble averaging. This procedure, however, suffers from two systematic errors when applied to particles that perform anomalous diffusion. The first is significant at short-time lags and is induced by measurement errors. The second arises from the natural heterogeneity in biophysical systems. We show how to estimate and correct these two errors and improve the estimation of the anomalous parameters for the whole particle distribution. As a consequence, we manage to characterize ensembles of heterogeneous particles even for rather short and noisy measurements where regular time-averaged mean square displacement analysis fails. We apply this method to both simulations and in vivo measurements of telomere diffusion in 3T3 mouse embryonic fibroblast cells. The motion of telomeres is found to be subdiffusive with an average exponent constant in time. Individual telomere exponents are normally distributed around the average exponent. The proposed methodology has the potential to improve experimental accuracy while maintaining lower experimental costs and complexity.
Astigmatism following retinal detachment surgery.
Goel, R; Crewdson, J; Chignell, A H
1983-01-01
Eighty-three patients on whom successful retinal detachment had been performed were studied to note astigmatic changes following surgery. In the majority of cases the errors following such surgery are of no great clinical importance. However, in some situations a high degree of astigmatism may be produced. This study showed that these sequelae are particularly likely after radial buckling procedures, and surgeons favouring these techniques should be aware that astigmatic errors can be induced. The astigmatic errors may persist for several years after surgery. PMID:6838807
ANSYS simulation of the capacitance coupling of quartz tuning fork gyroscope
NASA Astrophysics Data System (ADS)
Zhang, Qing; Feng, Lihui; Zhao, Ke; Cui, Fang; Sun, Yu-nan
2013-12-01
Coupling error is one of the main error sources of the quartz tuning fork gyroscope. The mechanism of capacitance coupling error is analyzed in this article. Finite Element Method (FEM) is used to simulate the structure of the quartz tuning fork by ANSYS software. The voltage output induced by the capacitance coupling is simulated with the harmonic analysis and characteristics of electrical and mechanical parameters influenced by the capacitance coupling between drive electrodes and sense electrodes are discussed with the transient analysis.
Dissociable Genetic Contributions to Error Processing: A Multimodal Neuroimaging Study
Agam, Yigal; Vangel, Mark; Roffman, Joshua L.; Gallagher, Patience J.; Chaponis, Jonathan; Haddad, Stephen; Goff, Donald C.; Greenberg, Jennifer L.; Wilhelm, Sabine; Smoller, Jordan W.; Manoach, Dara S.
2014-01-01
Background Neuroimaging studies reliably identify two markers of error commission: the error-related negativity (ERN), an event-related potential, and functional MRI activation of the dorsal anterior cingulate cortex (dACC). While theorized to reflect the same neural process, recent evidence suggests that the ERN arises from the posterior cingulate cortex not the dACC. Here, we tested the hypothesis that these two error markers also have different genetic mediation. Methods We measured both error markers in a sample of 92 comprised of healthy individuals and those with diagnoses of schizophrenia, obsessive-compulsive disorder or autism spectrum disorder. Participants performed the same task during functional MRI and simultaneously acquired magnetoencephalography and electroencephalography. We examined the mediation of the error markers by two single nucleotide polymorphisms: dopamine D4 receptor (DRD4) C-521T (rs1800955), which has been associated with the ERN and methylenetetrahydrofolate reductase (MTHFR) C677T (rs1801133), which has been associated with error-related dACC activation. We then compared the effects of each polymorphism on the two error markers modeled as a bivariate response. Results We replicated our previous report of a posterior cingulate source of the ERN in healthy participants in the schizophrenia and obsessive-compulsive disorder groups. The effect of genotype on error markers did not differ significantly by diagnostic group. DRD4 C-521T allele load had a significant linear effect on ERN amplitude, but not on dACC activation, and this difference was significant. MTHFR C677T allele load had a significant linear effect on dACC activation but not ERN amplitude, but the difference in effects on the two error markers was not significant. Conclusions DRD4 C-521T, but not MTHFR C677T, had a significant differential effect on two canonical error markers. Together with the anatomical dissociation between the ERN and error-related dACC activation, these findings suggest that these error markers have different neural and genetic mediation. PMID:25010186
On the use of biomathematical models in patient-specific IMRT dose QA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhen Heming; Nelms, Benjamin E.; Tome, Wolfgang A.
2013-07-15
Purpose: To investigate the use of biomathematical models such as tumor control probability (TCP) and normal tissue complication probability (NTCP) as new quality assurance (QA) metrics.Methods: Five different types of error (MLC transmission, MLC penumbra, MLC tongue and groove, machine output, and MLC position) were intentionally induced to 40 clinical intensity modulated radiation therapy (IMRT) patient plans (20 H and N cases and 20 prostate cases) to simulate both treatment planning system errors and machine delivery errors in the IMRT QA process. The changes in TCP and NTCP for eight different anatomic structures (H and N: CTV, GTV, both parotids,more » spinal cord, larynx; prostate: CTV, rectal wall) were calculated as the new QA metrics to quantify the clinical impact on patients. The correlation between the change in TCP/NTCP and the change in selected DVH values was also evaluated. The relation between TCP/NTCP change and the characteristics of the TCP/NTCP curves is discussed.Results:{Delta}TCP and {Delta}NTCP were summarized for each type of induced error and each structure. The changes/degradations in TCP and NTCP caused by the errors vary widely depending on dose patterns unique to each plan, and are good indicators of each plan's 'robustness' to that type of error.Conclusions: In this in silico QA study the authors have demonstrated the possibility of using biomathematical models not only as patient-specific QA metrics but also as objective indicators that quantify, pretreatment, a plan's robustness with respect to possible error types.« less
CCD image sensor induced error in PIV applications
NASA Astrophysics Data System (ADS)
Legrand, M.; Nogueira, J.; Vargas, A. A.; Ventas, R.; Rodríguez-Hidalgo, M. C.
2014-06-01
The readout procedure of charge-coupled device (CCD) cameras is known to generate some image degradation in different scientific imaging fields, especially in astrophysics. In the particular field of particle image velocimetry (PIV), widely extended in the scientific community, the readout procedure of the interline CCD sensor induces a bias in the registered position of particle images. This work proposes simple procedures to predict the magnitude of the associated measurement error. Generally, there are differences in the position bias for the different images of a certain particle at each PIV frame. This leads to a substantial bias error in the PIV velocity measurement (˜0.1 pixels). This is the order of magnitude that other typical PIV errors such as peak-locking may reach. Based on modern CCD technology and architecture, this work offers a description of the readout phenomenon and proposes a modeling for the CCD readout bias error magnitude. This bias, in turn, generates a velocity measurement bias error when there is an illumination difference between two successive PIV exposures. The model predictions match the experiments performed with two 12-bit-depth interline CCD cameras (MegaPlus ES 4.0/E incorporating the Kodak KAI-4000M CCD sensor with 4 megapixels). For different cameras, only two constant values are needed to fit the proposed calibration model and predict the error from the readout procedure. Tests by different researchers using different cameras would allow verification of the model, that can be used to optimize acquisition setups. Simple procedures to obtain these two calibration values are also described.
NASA Astrophysics Data System (ADS)
Richter, J.; Mayer, J.; Weigand, B.
2018-02-01
Non-resonant laser-induced thermal acoustics (LITA) was applied to measure Mach number, temperature and turbulence level along the centerline of a transonic nozzle flow. The accuracy of the measurement results was systematically studied regarding misalignment of the interrogation beam and frequency analysis of the LITA signals. 2D steady-state Reynolds-averaged Navier-Stokes (RANS) simulations were performed for reference. The simulations were conducted using ANSYS CFX 18 employing the shear-stress transport turbulence model. Post-processing of the LITA signals is performed by applying a discrete Fourier transformation (DFT) to determine the beat frequencies. It is shown that the systematical error of the DFT, which depends on the number of oscillations, signal chirp, and damping rate, is less than 1.5% for our experiments resulting in an average error of 1.9% for Mach number. Further, the maximum calibration error is investigated for a worst-case scenario involving maximum in situ readjustment of the interrogation beam within the limits of constructive interference. It is shown that the signal intensity becomes zero if the interrogation angle is altered by 2%. This, together with the accuracy of frequency analysis, results in an error of about 5.4% for temperature throughout the nozzle. Comparison with numerical results shows good agreement within the error bars.
Niccum, Brittany A; Lee, Heewook; MohammedIsmail, Wazim; Tang, Haixu; Foster, Patricia L
2018-06-15
When the DNA polymerase that replicates the Escherichia coli chromosome, DNA Pol III, makes an error, there are two primary defenses against mutation: proofreading by the epsilon subunit of the holoenzyme and mismatch repair. In proofreading deficient strains, mismatch repair is partially saturated and the cell's response to DNA damage, the SOS response, may be partially induced. To investigate the nature of replication errors, we used mutation accumulation experiments and whole genome sequencing to determine mutation rates and mutational spectra across the entire chromosome of strains deficient in proofreading, mismatch repair, and the SOS response. We report that a proofreading-deficient strain has a mutation rate 4,000-fold greater than wild-type strains. While the SOS response may be induced in these cells, it does not contribute to the mutational load. Inactivating mismatch repair in a proofreading-deficient strain increases the mutation rate another 1.5-fold. DNA polymerase has a bias for converting G:C to A:T base pairs, but proofreading reduces the impact of these mutations, helping to maintain the genomic G:C content. These findings give an unprecedented view of how polymerase and error-correction pathways work together to maintain E. coli' s low mutation rate of 1 per thousand generations. Copyright © 2018, Genetics.
A procedure for the significance testing of unmodeled errors in GNSS observations
NASA Astrophysics Data System (ADS)
Li, Bofeng; Zhang, Zhetao; Shen, Yunzhong; Yang, Ling
2018-01-01
It is a crucial task to establish a precise mathematical model for global navigation satellite system (GNSS) observations in precise positioning. Due to the spatiotemporal complexity of, and limited knowledge on, systematic errors in GNSS observations, some residual systematic errors would inevitably remain even after corrected with empirical model and parameterization. These residual systematic errors are referred to as unmodeled errors. However, most of the existing studies mainly focus on handling the systematic errors that can be properly modeled and then simply ignore the unmodeled errors that may actually exist. To further improve the accuracy and reliability of GNSS applications, such unmodeled errors must be handled especially when they are significant. Therefore, a very first question is how to statistically validate the significance of unmodeled errors. In this research, we will propose a procedure to examine the significance of these unmodeled errors by the combined use of the hypothesis tests. With this testing procedure, three components of unmodeled errors, i.e., the nonstationary signal, stationary signal and white noise, are identified. The procedure is tested by using simulated data and real BeiDou datasets with varying error sources. The results show that the unmodeled errors can be discriminated by our procedure with approximately 90% confidence. The efficiency of the proposed procedure is further reassured by applying the time-domain Allan variance analysis and frequency-domain fast Fourier transform. In summary, the spatiotemporally correlated unmodeled errors are commonly existent in GNSS observations and mainly governed by the residual atmospheric biases and multipath. Their patterns may also be impacted by the receiver.
Diuk, Carlos; Tsai, Karin; Wallis, Jonathan; Botvinick, Matthew; Niv, Yael
2013-03-27
Studies suggest that dopaminergic neurons report a unitary, global reward prediction error signal. However, learning in complex real-life tasks, in particular tasks that show hierarchical structure, requires multiple prediction errors that may coincide in time. We used functional neuroimaging to measure prediction error signals in humans performing such a hierarchical task involving simultaneous, uncorrelated prediction errors. Analysis of signals in a priori anatomical regions of interest in the ventral striatum and the ventral tegmental area indeed evidenced two simultaneous, but separable, prediction error signals corresponding to the two levels of hierarchy in the task. This result suggests that suitably designed tasks may reveal a more intricate pattern of firing in dopaminergic neurons. Moreover, the need for downstream separation of these signals implies possible limitations on the number of different task levels that we can learn about simultaneously.
Change in corneal aberrations after cataract surgery with 2 types of aspherical intraocular lenses.
Marcos, Susana; Rosales, Patricia; Llorente, Lourdes; Jiménez-Alfaro, Ignacio
2007-02-01
To study the effect of cataract surgery through 3.2 mm superior incisions on corneal aberrations with 2 types of monofocal intraocular lenses (IOLs) with an aspherical design. Instituto de Optica, Consejo Superior de Investigaciones Científicas, and Fundación Jiménez Díaz, Madrid, Spain. Corneal topography of 43 eyes was obtained before and after small corneal incision cataract surgery. Twenty-two eyes had implantation of a Tecnis Z9000 silicone IOL (Advanced Medical Optics) and 21 had implantation of an AcrySof IQ SN60WF acrylic IOL (Alcon Research Labs) using the recommended injector for each IOL type. The intended incision size (3.2 mm) was similar in the 2 groups. Corneal aberrations were estimated using custom-developed algorithms (based on ray tracing) for 10.0 mm and 5.0 mm pupils. Comparisons between preoperative and postoperative measurements and across the groups were made for individual Zernike terms and root-mean-square (RMS) wavefront error. The RMS (excluding tilt and defocus) did not change in the AcrySof IQ group and increased significantly in the Tecnis group with the 10.0 mm and 5.0 mm pupil diameters. Spherical aberration and coma-like terms did not change significantly; however, vertical astigmatism, vertical trefoil, and vertical tetrafoil changed significantly with surgery with the 10.0 mm and 5.0 mm pupil diameters (P<.0005). The induced wave aberration pattern for 3rd- and higher-order aberrations consistently showed a superior lobe, resulting from a combination of positive vertical trefoil (Z(3)(-3)) and negative tetrafoil (Z(4)(4)). The mean vertical astigmatism increased by 2.47 microm +/- 1.49 (SD) and 1.74 +/- 1.44 microm, vertical trefoil increased by 1.81 +/- 1.19 microm and 1.20 +/- 1.34 microm, and tetrafoil increased by -1.10 +/- 0.78 microm and -0.89 +/- 0.68 microm in the Tecnis group and AcrySof IQ group, respectively. There were no significant differences between the corneal aberrations in the 2 postoperative groups, although there was a tendency toward more terms or orders changing statistically significantly in the Tecnis group, which had slightly higher amounts of induced aberrations. Cataract surgery with a small superior incision induced consistent and significant changes in several corneal Zernike terms (vertical astigmatism, trefoil, and tetrafoil), resulting in a significantly increased overall corneal RMS wavefront error. These results can be used to improve predictions of optical performance with new IOL designs using computer eye models and identify the potentially different impact of incision strategies on cataract surgery.
NASA Technical Reports Server (NTRS)
Green, Del L.; Walker, Eric L.; Everhart, Joel L.
2006-01-01
Minimization of uncertainty is essential to extend the usable range of the 15-psid Electronically Scanned Pressure [ESP) transducer measurements to the low free-stream static pressures found in hypersonic wind tunnels. Statistical characterization of environmental error sources inducing much of this uncertainty requires a well defined and controlled calibration method. Employing such a controlled calibration system, several studies were conducted that provide quantitative information detailing the required controls needed to minimize environmental and human induced error sources. Results of temperature, environmental pressure, over-pressurization, and set point randomization studies for the 15-psid transducers are presented along with a comparison of two regression methods using data acquired with both 0.36-psid and 15-psid transducers. Together these results provide insight into procedural and environmental controls required for long term high-accuracy pressure measurements near 0.01 psia in the hypersonic testing environment using 15-psid ESP transducers.
NASA Technical Reports Server (NTRS)
Green, Del L.; Walker, Eric L.; Everhart, Joel L.
2006-01-01
Minimization of uncertainty is essential to extend the usable range of the 15-psid Electronically Scanned Pressure (ESP) transducer measurements to the low free-stream static pressures found in hypersonic wind tunnels. Statistical characterization of environmental error sources inducing much of this uncertainty requires a well defined and controlled calibration method. Employing such a controlled calibration system, several studies were conducted that provide quantitative information detailing the required controls needed to minimize environmental and human induced error sources. Results of temperature, environmental pressure, over-pressurization, and set point randomization studies for the 15-psid transducers are presented along with a comparison of two regression methods using data acquired with both 0.36-psid and 15-psid transducers. Together these results provide insight into procedural and environmental controls required for long term high-accuracy pressure measurements near 0.01 psia in the hypersonic testing environment using 15-psid ESP transducers.
Middione, Matthew J; Thompson, Richard B; Ennis, Daniel B
2014-06-01
To investigate a novel phase-contrast MRI velocity-encoding technique for faster imaging and reduced chemical shift-induced phase errors. Velocity encoding with the slice select refocusing gradient achieves the target gradient moment by time shifting the refocusing gradient, which enables the use of the minimum in-phase echo time (TE) for faster imaging and reduced chemical shift-induced phase errors. Net forward flow was compared in 10 healthy subjects (N = 10) within the ascending aorta (aAo), main pulmonary artery (PA), and right/left pulmonary arteries (RPA/LPA) using conventional flow compensated and flow encoded (401 Hz/px and TE = 3.08 ms) and slice select refocused gradient velocity encoding (814 Hz/px and TE = 2.46 ms) at 3 T. Improved net forward flow agreement was measured across all vessels for slice select refocused gradient compared to flow compensated and flow encoded: aAo vs. PA (1.7% ± 1.9% vs. 5.8% ± 2.8%, P = 0.002), aAo vs. RPA + LPA (2.1% ± 1.7% vs. 6.0% ± 4.3%, P = 0.03), and PA vs. RPA + LPA (2.9% ± 2.1% vs. 6.1% ± 6.3%, P = 0.04), while increasing temporal resolution (35%) and signal-to-noise ratio (33%). Slice select refocused gradient phase-contrast MRI with a high receiver bandwidth and minimum in-phase TE provides more accurate and less variable flow measurements through the reduction of chemical shift-induced phase errors and a reduced TE/repetition time, which can be used to increase the temporal/spatial resolution and/or reduce breath hold durations. Copyright © 2013 Wiley Periodicals, Inc.
Gibbs, P E; Kilbey, B J; Banerjee, S K; Lawrence, C W
1993-05-01
We have compared the mutagenic properties of a T-T cyclobutane dimer in baker's yeast, Saccharomyces cerevisiae, with those in Escherichia coli by transforming each of these species with the same single-stranded shuttle vector carrying either the cis-syn or the trans-syn isomer of this UV photoproduct at a unique site. The mutagenic properties investigated were the frequency of replicational bypass of the photoproduct, the error rate of bypass, and the mutation spectrum. In SOS-induced E. coli, the cis-syn dimer was bypassed in approximately 16% of the vector molecules, and 7.6% of the bypass products had targeted mutations. In S. cerevisiae, however, bypass occurred in about 80% of these molecules, and the bypass was at least 19-fold more accurate (approximately 0.4% targeted mutations). Each of these yeast mutations was a single unique event, and none were like those in E. coli, suggesting that in fact the difference in error rate is much greater. Bypass of the trans-syn dimer occurred in about 17% of the vector molecules in both species, but with this isomer the error rate was higher in S. cerevisiae (21 to 36% targeted mutations) than in E. coli (13%). However, the spectra of mutations induced by the latter photoproduct were virtually identical in the two organisms. We conclude that bypass and error frequencies are determined both by the structure of the photoproduct-containing template and by the particular replication proteins concerned but that the types of mutations induced depend predominantly on the structure of the template. Unlike E. coli, bypass in S. cerevisiae did not require UV-induced functions.
NASA Technical Reports Server (NTRS)
Barrie, A. C.; Smith, S. E.; Dorelli, J. C.; Gershman, D. J.; Yeh, P.; Schiff, C.; Avanov, L. A.
2017-01-01
Data compression has been a staple of imaging instruments for years. Recently, plasma measurements have utilized compression with relatively low compression ratios. The Fast Plasma Investigation (FPI) on board the Magnetospheric Multiscale (MMS) mission generates data roughly 100 times faster than previous plasma instruments, requiring a higher compression ratio to fit within the telemetry allocation. This study investigates the performance of a space-based compression standard employing a Discrete Wavelet Transform and a Bit Plane Encoder (DWT/BPE) in compressing FPI plasma count data. Data from the first 6 months of FPI operation are analyzed to explore the error modes evident in the data and how to adapt to them. While approximately half of the Dual Electron Spectrometer (DES) maps had some level of loss, it was found that there is little effect on the plasma moments and that errors present in individual sky maps are typically minor. The majority of Dual Ion Spectrometer burst sky maps compressed in a lossless fashion, with no error introduced during compression. Because of induced compression error, the size limit for DES burst images has been increased for Phase 1B. Additionally, it was found that the floating point compression mode yielded better results when images have significant compression error, leading to floating point mode being used for the fast survey mode of operation for Phase 1B. Despite the suggested tweaks, it was found that wavelet-based compression, and a DWT/BPE algorithm in particular, is highly suitable to data compression for plasma measurement instruments and can be recommended for future missions.
Research on key technologies of LADAR echo signal simulator
NASA Astrophysics Data System (ADS)
Xu, Rui; Shi, Rui; Ye, Jiansen; Wang, Xin; Li, Zhuo
2015-10-01
LADAR echo signal simulator is one of the most significant components of hardware-in-the-loop (HWIL) simulation systems for LADAR, which is designed to simulate the LADAR return signal in laboratory conditions. The device can provide the laser echo signal of target and background for imaging LADAR systems to test whether it is of good performance. Some key technologies are investigated in this paper. Firstly, the 3D model of typical target is built, and transformed to the data of the target echo signal based on ranging equation and targets reflection characteristics. Then, system model and time series model of LADAR echo signal simulator are established. Some influential factors which could induce fixed delay error and random delay error on the simulated return signals are analyzed. In the simulation system, the signal propagating delay of circuits and the response time of pulsed lasers are belong to fixed delay error. The counting error of digital delay generator, the jitter of system clock and the desynchronized between trigger signal and clock signal are a part of random delay error. Furthermore, these system insertion delays are analyzed quantitatively, and the noisy data are obtained. The target echo signals are got by superimposing of the noisy data and the pure target echo signal. In order to overcome these disadvantageous factors, a method of adjusting the timing diagram of the simulation system is proposed. Finally, the simulated echo signals are processed by using a detection algorithm to complete the 3D model reconstruction of object. The simulation results reveal that the range resolution can be better than 8 cm.
NASA Astrophysics Data System (ADS)
Johnson, Traci L.; Sharon, Keren
2016-11-01
Until now, systematic errors in strong gravitational lens modeling have been acknowledged but have never been fully quantified. Here, we launch an investigation into the systematics induced by constraint selection. We model the simulated cluster Ares 362 times using random selections of image systems with and without spectroscopic redshifts and quantify the systematics using several diagnostics: image predictability, accuracy of model-predicted redshifts, enclosed mass, and magnification. We find that for models with >15 image systems, the image plane rms does not decrease significantly when more systems are added; however, the rms values quoted in the literature may be misleading as to the ability of a model to predict new multiple images. The mass is well constrained near the Einstein radius in all cases, and systematic error drops to <2% for models using >10 image systems. Magnification errors are smallest along the straight portions of the critical curve, and the value of the magnification is systematically lower near curved portions. For >15 systems, the systematic error on magnification is ∼2%. We report no trend in magnification error with the fraction of spectroscopic image systems when selecting constraints at random; however, when using the same selection of constraints, increasing this fraction up to ∼0.5 will increase model accuracy. The results suggest that the selection of constraints, rather than quantity alone, determines the accuracy of the magnification. We note that spectroscopic follow-up of at least a few image systems is crucial because models without any spectroscopic redshifts are inaccurate across all of our diagnostics.
Tam, Nicoladie D
2013-01-01
This study aims to identify the acute effects of physical exercise on specific cognitive functions immediately following an increase in cardiovascular activity. Stair-climbing exercise is used to increase the cardiovascular output of human subjects. The color-naming Stroop Test was used to identify the cognitive improvements in executive function with respect to processing speed and error rate. The study compared the Stroop results before and immediately after exercise and before and after nonexercise, as a control. The results show that there is a significant increase in processing speed and a reduction in errors immediately after less than 30 min of aerobic exercise. The improvements are greater for the incongruent than for the congruent color tests. This suggests that physical exercise induces a better performance in a task that requires resolving conflict (or interference) than a task that does not. There is no significant improvement for the nonexercise control trials. This demonstrates that an increase in cardiovascular activity has significant acute effects on improving the executive function that requires conflict resolution (for the incongruent color tests) immediately following aerobic exercise more than similar executive functions that do not require conflict resolution or involve the attention-inhibition process (for the congruent color tests).
NASA Technical Reports Server (NTRS)
1987-01-01
In a complex computer environment there is ample opportunity for error, a mistake by a programmer, or a software-induced undesirable side effect. In insurance, errors can cost a company heavily, so protection against inadvertent change is a must for the efficient firm. The data processing center at Transport Life Insurance Company has taken a step to guard against accidental changes by adopting a software package called EQNINT (Equations Interpreter Program). EQNINT cross checks the basic formulas in a program against the formulas that make up the major production system. EQNINT assures that formulas are coded correctly and helps catch errors before they affect the customer service or its profitability.
Reversal of photon-scattering errors in atomic qubits.
Akerman, N; Kotler, S; Glickman, Y; Ozeri, R
2012-09-07
Spontaneous photon scattering by an atomic qubit is a notable example of environment-induced error and is a fundamental limit to the fidelity of quantum operations. In the scattering process, the qubit loses its distinctive and coherent character owing to its entanglement with the photon. Using a single trapped ion, we show that by utilizing the information carried by the photon, we are able to coherently reverse this process and correct for the scattering error. We further used quantum process tomography to characterize the photon-scattering error and its correction scheme and demonstrate a correction fidelity greater than 85% whenever a photon was measured.
Watson, C J; Pierach, C A; Bossenmaier, I; Cardinal, R
1977-01-01
There is compelling, indirect evidence of hepatic heme deficiency due primarily to the respective genetic errors of the three inducible hepatic porphyrias, acute intermittent porphyria, porphyria variegata, and hereditary coproporphyria. The induction is enhanced by exogenous inducers such as barbiturate, estrogens and other "porphyrogenic" chemicals and factors, including glucose deprivation. The newer knowledge of the induction of delta-aminolevulinic acid synthetase [delta-aminolevulinate synthase; succinyl--CoA:glycine C-succinyltransferase (decarboxylating), EC 2.3.1.37] in relation to inadequate heme, and repression by heme, stimulated early trials of hematin infusions to overcome the acute relapse in the foregoing inducible porphyrias. Recently this experience has been considerably expanded, 143 infusions of hematin having been given in 22 cases. Studies of the effect on the serum concentrations of delta-aminolevulinic acid and porphobilinogen have shown a highly significant decline, often to 0, especially of delta-aminolevulinic acid. A distinct relationship to the clinical severity of the attack has been evident in the frequency and magnitude of decline of serum delta-aminolevulinic acid and porphobilinogen. This was regularly associated with objective clinical improvement. PMID:266732
[Stress-induced cellular adaptive mutagenesis].
Zhu, Linjiang; Li, Qi
2014-04-01
The adaptive mutations exist widely in the evolution of cells, such as antibiotic resistance mutations of pathogenic bacteria, adaptive evolution of industrial strains, and cancerization of human somatic cells. However, how these adaptive mutations are generated is still controversial. Based on the mutational analysis models under the nonlethal selection conditions, stress-induced cellular adaptive mutagenesis is proposed as a new evolutionary viewpoint. The hypothetic pathway of stress-induced mutagenesis involves several intracellular physiological responses, including DNA damages caused by accumulation of intracellular toxic chemicals, limitation of DNA MMR (mismatch repair) activity, upregulation of general stress response and activation of SOS response. These responses directly affect the accuracy of DNA replication from a high-fidelity manner to an error-prone one. The state changes of cell physiology significantly increase intracellular mutation rate and recombination activity. In addition, gene transcription under stress condition increases the instability of genome in response to DNA damage, resulting in transcription-associated DNA mutagenesis. In this review, we summarize these two molecular mechanisms of stress-induced mutagenesis and transcription-associated DNA mutagenesis to help better understand the mechanisms of adaptive mutagenesis.
Speedup computation of HD-sEMG signals using a motor unit-specific electrical source model.
Carriou, Vincent; Boudaoud, Sofiane; Laforet, Jeremy
2018-01-23
Nowadays, bio-reliable modeling of muscle contraction is becoming more accurate and complex. This increasing complexity induces a significant increase in computation time which prevents the possibility of using this model in certain applications and studies. Accordingly, the aim of this work is to significantly reduce the computation time of high-density surface electromyogram (HD-sEMG) generation. This will be done through a new model of motor unit (MU)-specific electrical source based on the fibers composing the MU. In order to assess the efficiency of this approach, we computed the normalized root mean square error (NRMSE) between several simulations on single generated MU action potential (MUAP) using the usual fiber electrical sources and the MU-specific electrical source. This NRMSE was computed for five different simulation sets wherein hundreds of MUAPs are generated and summed into HD-sEMG signals. The obtained results display less than 2% error on the generated signals compared to the same signals generated with fiber electrical sources. Moreover, the computation time of the HD-sEMG signal generation model is reduced to about 90% compared to the fiber electrical source model. Using this model with MU electrical sources, we can simulate HD-sEMG signals of a physiological muscle (hundreds of MU) in less than an hour on a classical workstation. Graphical Abstract Overview of the simulation of HD-sEMG signals using the fiber scale and the MU scale. Upscaling the electrical source to the MU scale reduces the computation time by 90% inducing only small deviation of the same simulated HD-sEMG signals.
Wavefront error budget and optical manufacturing tolerance analysis for 1.8m telescope system
NASA Astrophysics Data System (ADS)
Wei, Kai; Zhang, Xuejun; Xian, Hao; Rao, Changhui; Zhang, Yudong
2010-05-01
We present the wavefront error budget and optical manufacturing tolerance analysis for 1.8m telescope. The error budget accounts for aberrations induced by optical design residual, manufacturing error, mounting effects, and misalignments. The initial error budget has been generated from the top-down. There will also be an ongoing effort to track the errors from the bottom-up. This will aid in identifying critical areas of concern. The resolution of conflicts will involve a continual process of review and comparison of the top-down and bottom-up approaches, modifying both as needed to meet the top level requirements in the end. As we all know, the adaptive optical system will correct for some of the telescope system imperfections but it cannot be assumed that all errors will be corrected. Therefore, two kinds of error budgets will be presented, one is non-AO top-down error budget and the other is with-AO system error budget. The main advantage of the method is that at the same time it describes the final performance of the telescope, and gives to the optical manufacturer the maximum freedom to define and possibly modify its own manufacturing error budget.
Chan, Tommy C Y; Ng, Alex L K; Cheng, George P M; Wang, Zheng; Ye, Cong; Woo, Victor C P; Tham, Clement C Y; Jhanji, Vishal
2016-04-01
To compare astigmatic correction between femtosecond-assisted laser in situ keratomileusis (LASIK) and small-incision lenticule extraction (SMILE). A total of 111 patients were included in this prospective study. Fifty-seven eyes were treated with LASIK and 54 eyes were treated with SMILE for myopia with low to moderate (-0.25 to -4.0 D) astigmatism. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity and manifest refraction were measured preoperatively and at 1 and 3 months postoperatively. Visual and refractive outcomes were reported. Changes in refractive astigmatism were evaluated using vector analysis. Preoperative characteristics were similar between both groups. The UDVA at 1 and 3 months was better in the LASIK group compared with the SMILE group (p<0.009). Postoperative cylinder was higher in the SMILE group (p<0.001). Fewer eyes attained the attempted cylindrical correction in the SMILE group (p<0.029). Vector analysis showed no significant difference in target-induced astigmatism (p=0.091) and angle of error (p>0.596) between the two groups. Surgically induced astigmatism was significantly lower in the SMILE group (p<0.023), while the difference vector (p<0.001) and absolute angle of error (p<0.016) were significantly higher in the SMILE group. No significant difference was found in these parameters between 1 and 3 months in both groups (p>0.122). Our results showed that SMILE offered a less favourable astigmatic correction comparable to femtosecond-assisted LASIK in eyes with low to moderate myopic astigmatism. The alignment of treatment was more variable in SMILE, leading to a lower efficacy compared with LASIK by 3 months postoperatively. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
XCO2 Retrieval Errors from a PCA-based Approach to Fast Radiative Transfer
NASA Astrophysics Data System (ADS)
Somkuti, Peter; Boesch, Hartmut; Natraj, Vijay; Kopparla, Pushkar
2017-04-01
Multiple-scattering radiative transfer (RT) calculations are an integral part of forward models used to infer greenhouse gas concentrations in the shortwave-infrared spectral range from satellite missions such as GOSAT or OCO-2. Such calculations are, however, computationally expensive and, combined with the recent growth in data volume, necessitate the use of acceleration methods in order to make retrievals feasible on an operational level. The principle component analysis (PCA)-based approach to fast radiative transfer introduced by Natraj et al. 2005 is a spectral binning method, in which the many line-by-line monochromatic calculations are replaced by a small set of representative ones. From the PCA performed on the optical layer properties for a scene-dependent atmosphere, the results of the representative calculations are mapped onto all spectral points in the given band. Since this RT scheme is an approximation, the computed top-of-atmosphere radiances exhibit errors compared to the "full" line-by-line calculation. These errors ultimately propagate into the final retrieved greenhouse gas concentrations, and their magnitude depends on scene-dependent parameters such as aerosol loadings or viewing geometry. An advantage of this method is the ability to choose the degree of accuracy by increasing or decreasing the number of empirical orthogonal functions used for the reconstruction of the radiances. We have performed a large set of global simulations based on real GOSAT scenes and assess the retrieval errors induced by the fast RT approximation through linear error analysis. We find that across a wide range of geophysical parameters, the errors are for the most part smaller than ± 0.2 ppm and ± 0.06 ppm (out of roughly 400 ppm) for ocean and land scenes respectively. A fast RT scheme that produces low errors is important, since regional biases in XCO2 even in the low sub-ppm range can cause significant changes in carbon fluxes obtained from inversions (Chevallier et al. 2007).
Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun; Seong, Gong Je
2017-03-01
To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R²=0.404). Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors.
Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun
2017-01-01
Purpose To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. Materials and Methods This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. Results In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R2=0.404). Conclusion Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors. PMID:28120576
Yang, Minglei; Ding, Hui; Zhu, Lei; Wang, Guangzhi
2016-12-01
Ultrasound fusion imaging is an emerging tool and benefits a variety of clinical applications, such as image-guided diagnosis and treatment of hepatocellular carcinoma and unresectable liver metastases. However, respiratory liver motion-induced misalignment of multimodal images (i.e., fusion error) compromises the effectiveness and practicability of this method. The purpose of this paper is to develop a subject-specific liver motion model and automatic registration-based method to correct the fusion error. An online-built subject-specific motion model and automatic image registration method for 2D ultrasound-3D magnetic resonance (MR) images were combined to compensate for the respiratory liver motion. The key steps included: 1) Build a subject-specific liver motion model for current subject online and perform the initial registration of pre-acquired 3D MR and intra-operative ultrasound images; 2) During fusion imaging, compensate for liver motion first using the motion model, and then using an automatic registration method to further correct the respiratory fusion error. Evaluation experiments were conducted on liver phantom and five subjects. In the phantom study, the fusion error (superior-inferior axis) was reduced from 13.90±2.38mm to 4.26±0.78mm by using the motion model only. The fusion error further decreased to 0.63±0.53mm by using the registration method. The registration method also decreased the rotation error from 7.06±0.21° to 1.18±0.66°. In the clinical study, the fusion error was reduced from 12.90±9.58mm to 6.12±2.90mm by using the motion model alone. Moreover, the fusion error decreased to 1.96±0.33mm by using the registration method. The proposed method can effectively correct the respiration-induced fusion error to improve the fusion image quality. This method can also reduce the error correction dependency on the initial registration of ultrasound and MR images. Overall, the proposed method can improve the clinical practicability of ultrasound fusion imaging. Copyright © 2016 Elsevier Ltd. All rights reserved.
The Influence of Different OK Lens Designs on Peripheral Refraction.
Kang, Pauline; Swarbrick, Helen
2016-09-01
To compare peripheral refraction changes along the horizontal and vertical meridians induced by three different orthokeratology (OK) lens designs: BE, Paragon CRT, and Contex lenses. Nineteen subjects (6M, 13F, mean age 28 ± 7 years) were initially fitted with BE OK lenses in both eyes which were worn overnight for 14 days. Central and peripheral refraction and corneal topography were measured at baseline and after 14 nights of lens wear. After a minimum 2-week washout period, one randomly selected eye was re-fitted with a Paragon CRT lens and the other eye with a Contex OK lens. Measurements were repeated before and after 14 nights of lens wear. The three different OK lenses caused significant changes in peripheral refraction along both the horizontal and vertical visual fields (VFs). BE and Paragon CRT lenses induced a significant hyperopic shift within the central ±20° along the horizontal VF and at all positions along the vertical meridian except at 30° in the superior VF. There were no significant differences in peripheral refraction changes induced between BE and Paragon CRT lenses. When comparing BE and Contex OK lens designs, BE caused greater hyperopic shifts at 10° and 30° in the temporal VF and at center, 10°, and 20° in the superior VF along the vertical meridian. Furthermore, BE lenses caused greater reduction in Flat and Steep K values compared to Contex OK. OK lenses induced significant changes in peripheral refraction along the horizontal and vertical meridians. Despite the clinically significant difference in central corneal flattening induced by BE and Contex OK lenses, relative peripheral refraction changes differed minimally between the three OK lens designs. If the peripheral retina influences refractive error development, these results suggest that myopia control effects are likely to be similar between different OK lens designs.
Bishop, Lauri; Khan, Moiz; Martelli, Dario; Quinn, Lori; Stein, Joel; Agrawal, Sunil
2017-10-01
Many robotic devices in rehabilitation incorporate an assist-as-needed haptic guidance paradigm to promote training. This error reduction model, while beneficial for skill acquisition, could be detrimental for long-term retention. Error augmentation (EA) models have been explored as alternatives. A robotic Tethered Pelvic Assist Device has been developed to study force application to the pelvis on gait and was used here to induce weight shift onto the paretic (error reduction) or nonparetic (error augmentation) limb during treadmill training. The purpose of these case reports is to examine effects of training with these two paradigms to reduce load force asymmetry during gait in two individuals after stroke (>6 mos). Participants presented with baseline gait asymmetry, although independent community ambulators. Participants underwent 1-hr trainings for 3 days using either the error reduction or error augmentation model. Outcomes included the Borg rating of perceived exertion scale for treatment tolerance and measures of force and stance symmetry. Both participants tolerated training. Force symmetry (measured on treadmill) improved from pretraining to posttraining (36.58% and 14.64% gains), however, with limited transfer to overground gait measures (stance symmetry gains of 9.74% and 16.21%). Training with the Tethered Pelvic Assist Device device proved feasible to improve force symmetry on the treadmill irrespective of training model. Future work should consider methods to increase transfer to overground gait.
Dokka, Kalpana; DeAngelis, Gregory C.
2015-01-01
Humans and animals are fairly accurate in judging their direction of self-motion (i.e., heading) from optic flow when moving through a stationary environment. However, an object moving independently in the world alters the optic flow field and may bias heading perception if the visual system cannot dissociate object motion from self-motion. We investigated whether adding vestibular self-motion signals to optic flow enhances the accuracy of heading judgments in the presence of a moving object. Macaque monkeys were trained to report their heading (leftward or rightward relative to straight-forward) when self-motion was specified by vestibular, visual, or combined visual-vestibular signals, while viewing a display in which an object moved independently in the (virtual) world. The moving object induced significant biases in perceived heading when self-motion was signaled by either visual or vestibular cues alone. However, this bias was greatly reduced when visual and vestibular cues together signaled self-motion. In addition, multisensory heading discrimination thresholds measured in the presence of a moving object were largely consistent with the predictions of an optimal cue integration strategy. These findings demonstrate that multisensory cues facilitate the perceptual dissociation of self-motion and object motion, consistent with computational work that suggests that an appropriate decoding of multisensory visual-vestibular neurons can estimate heading while discounting the effects of object motion. SIGNIFICANCE STATEMENT Objects that move independently in the world alter the optic flow field and can induce errors in perceiving the direction of self-motion (heading). We show that adding vestibular (inertial) self-motion signals to optic flow almost completely eliminates the errors in perceived heading induced by an independently moving object. Furthermore, this increased accuracy occurs without a substantial loss in the precision. Our results thus demonstrate that vestibular signals play a critical role in dissociating self-motion from object motion. PMID:26446214
Performance monitoring and error significance in patients with obsessive-compulsive disorder.
Endrass, Tanja; Schuermann, Beate; Kaufmann, Christan; Spielberg, Rüdiger; Kniesche, Rainer; Kathmann, Norbert
2010-05-01
Performance monitoring has been consistently found to be overactive in obsessive-compulsive disorder (OCD). The present study examines whether performance monitoring in OCD is adjusted with error significance. Therefore, errors in a flanker task were followed by neutral (standard condition) or punishment feedbacks (punishment condition). In the standard condition patients had significantly larger error-related negativity (ERN) and correct-related negativity (CRN) ampliudes than controls. But, in the punishment condition groups did not differ in ERN and CRN amplitudes. While healthy controls showed an amplitude enhancement between standard and punishment condition, OCD patients showed no variation. In contrast, group differences were not found for the error positivity (Pe): both groups had larger Pe amplitudes in the punishment condition. Results confirm earlier findings of overactive error monitoring in OCD. The absence of a variation with error significance might indicate that OCD patients are unable to down-regulate their monitoring activity according to external requirements. Copyright 2010 Elsevier B.V. All rights reserved.
Nonlinear forecasting as a way of distinguishing chaos from measurement error in time series
NASA Astrophysics Data System (ADS)
Sugihara, George; May, Robert M.
1990-04-01
An approach is presented for making short-term predictions about the trajectories of chaotic dynamical systems. The method is applied to data on measles, chickenpox, and marine phytoplankton populations, to show how apparent noise associated with deterministic chaos can be distinguished from sampling error and other sources of externally induced environmental noise.
ERIC Educational Resources Information Center
Smalle, Eleonore H. M.; Muylle, Merel; Szmalec, Arnaud; Duyck, Wouter
2017-01-01
Speech errors typically respect the speaker's implicit knowledge of language-wide phonotactics (e.g., /t/ cannot be a syllable onset in the English language). Previous work demonstrated that adults can learn novel experimentally induced phonotactic constraints by producing syllable strings in which the allowable position of a phoneme depends on…
Adjusting Satellite Rainfall Error in Mountainous Areas for Flood Modeling Applications
NASA Astrophysics Data System (ADS)
Zhang, X.; Anagnostou, E. N.; Astitha, M.; Vergara, H. J.; Gourley, J. J.; Hong, Y.
2014-12-01
This study aims to investigate the use of high-resolution Numerical Weather Prediction (NWP) for evaluating biases of satellite rainfall estimates of flood-inducing storms in mountainous areas and associated improvements in flood modeling. Satellite-retrieved precipitation has been considered as a feasible data source for global-scale flood modeling, given that satellite has the spatial coverage advantage over in situ (rain gauges and radar) observations particularly over mountainous areas. However, orographically induced heavy precipitation events tend to be underestimated and spatially smoothed by satellite products, which error propagates non-linearly in flood simulations.We apply a recently developed retrieval error and resolution effect correction method (Zhang et al. 2013*) on the NOAA Climate Prediction Center morphing technique (CMORPH) product based on NWP analysis (or forecasting in the case of real-time satellite products). The NWP rainfall is derived from the Weather Research and Forecasting Model (WRF) set up with high spatial resolution (1-2 km) and explicit treatment of precipitation microphysics.In this study we will show results on NWP-adjusted CMORPH rain rates based on tropical cyclones and a convective precipitation event measured during NASA's IPHEX experiment in the South Appalachian region. We will use hydrologic simulations over different basins in the region to evaluate propagation of bias correction in flood simulations. We show that the adjustment reduced the underestimation of high rain rates thus moderating the strong rainfall magnitude dependence of CMORPH rainfall bias, which results in significant improvement in flood peak simulations. Further study over Blue Nile Basin (western Ethiopia) will be investigated and included in the presentation. *Zhang, X. et al. 2013: Using NWP Simulations in Satellite Rainfall Estimation of Heavy Precipitation Events over Mountainous Areas. J. Hydrometeor, 14, 1844-1858.
At the cross-roads: an on-road examination of driving errors at intersections.
Young, Kristie L; Salmon, Paul M; Lenné, Michael G
2013-09-01
A significant proportion of road trauma occurs at intersections. Understanding the nature of driving errors at intersections therefore has the potential to lead to significant injury reductions. To further understand how the complexity of modern intersections shapes behaviour of these errors are compared to errors made mid-block, and the role of wider systems failures in intersection error causation is investigated in an on-road study. Twenty-five participants drove a pre-determined urban route incorporating 25 intersections. Two in-vehicle observers recorded the errors made while a range of other data was collected, including driver verbal protocols, video, driver eye glance behaviour and vehicle data (e.g., speed, braking and lane position). Participants also completed a post-trial cognitive task analysis interview. Participants were found to make 39 specific error types, with speeding violations the most common. Participants made significantly more errors at intersections compared to mid-block, with misjudgement, action and perceptual/observation errors more commonly observed at intersections. Traffic signal configuration was found to play a key role in intersection error causation, with drivers making more errors at partially signalised compared to fully signalised intersections. Copyright © 2012 Elsevier Ltd. All rights reserved.
Cullen, Jared; Lobo, Charlene J; Ford, Michael J; Toth, Milos
2015-09-30
Electron-beam-induced deposition (EBID) is a direct-write chemical vapor deposition technique in which an electron beam is used for precursor dissociation. Here we show that Arrhenius analysis of the deposition rates of nanostructures grown by EBID can be used to deduce the diffusion energies and corresponding preexponential factors of EBID precursor molecules. We explain the limitations of this approach, define growth conditions needed to minimize errors, and explain why the errors increase systematically as EBID parameters diverge from ideal growth conditions. Under suitable deposition conditions, EBID can be used as a localized technique for analysis of adsorption barriers and prefactors.
Constraints on a scale-dependent bias from galaxy clustering
NASA Astrophysics Data System (ADS)
Amendola, L.; Menegoni, E.; Di Porto, C.; Corsi, M.; Branchini, E.
2017-01-01
We forecast the future constraints on scale-dependent parametrizations of galaxy bias and their impact on the estimate of cosmological parameters from the power spectrum of galaxies measured in a spectroscopic redshift survey. For the latter we assume a wide survey at relatively large redshifts, similar to the planned Euclid survey, as the baseline for future experiments. To assess the impact of the bias we perform a Fisher matrix analysis, and we adopt two different parametrizations of scale-dependent bias. The fiducial models for galaxy bias are calibrated using mock catalogs of H α emitting galaxies mimicking the expected properties of the objects that will be targeted by the Euclid survey. In our analysis we have obtained two main results. First of all, allowing for a scale-dependent bias does not significantly increase the errors on the other cosmological parameters apart from the rms amplitude of density fluctuations, σ8 , and the growth index γ , whose uncertainties increase by a factor up to 2, depending on the bias model adopted. Second, we find that the accuracy in the linear bias parameter b0 can be estimated to within 1%-2% at various redshifts regardless of the fiducial model. The nonlinear bias parameters have significantly large errors that depend on the model adopted. Despite this, in the more realistic scenarios departures from the simple linear bias prescription can be detected with a ˜2 σ significance at each redshift explored. Finally, we use the Fisher matrix formalism to assess the impact od assuming an incorrect bias model and find that the systematic errors induced on the cosmological parameters are similar or even larger than the statistical ones.
Joint Source Location and Focal Mechanism Inversion: efficiency, accuracy and applications
NASA Astrophysics Data System (ADS)
Liang, C.; Yu, Y.
2017-12-01
The analysis of induced seismicity has become a common practice to evaluate the results of hydraulic fracturing treatment. Liang et al (2016) proposed a joint Source Scanning Algorithms (jSSA for short) to obtain microseismic events and focal mechanisms simultaneously. The jSSA is superior over traditional SSA in many aspects, but the computation cost is too significant to be applied in real time monitoring. In this study, we have developed several scanning schemas to reduce computation time. A multi-stage scanning schema is proved to be able to improve the efficiency significantly while also retain its accuracy. A series of tests have been carried out by using both real field data and synthetic data to evaluate the accuracy of the method and its dependence on noise level, source depths, focal mechanisms and other factors. The surface-based arrays have better constraints on horizontal location errors (<20m) and angular errors of P axes (within 10 degree, for S/N>0.5). For sources with varying rakes, dips, strikes and depths, the errors are mostly controlled by the partition of positive and negative polarities in different quadrants. More evenly partitioned polarities in different quadrants yield better results in both locations and focal mechanisms. Nevertheless, even with bad resolutions for some FMs, the optimized jSSA method can still improve location accuracies significantly. Based on much more densely distributed events and focal mechanisms, a gridded stress inversion is conducted to get a evenly distributed stress field. The full potential of the jSSA has yet to be explored in different directions, especially in earthquake seismology as seismic array becoming incleasingly dense.
Kadlecek, Stephen; Hamedani, Hooman; Xu, Yinan; Emami, Kiarash; Xin, Yi; Ishii, Masaru; Rizi, Rahim
2013-10-01
Alveolar oxygen tension (Pao2) is sensitive to the interplay between local ventilation, perfusion, and alveolar-capillary membrane permeability, and thus reflects physiologic heterogeneity of healthy and diseased lung function. Several hyperpolarized helium ((3)He) magnetic resonance imaging (MRI)-based Pao2 mapping techniques have been reported, and considerable effort has gone toward reducing Pao2 measurement error. We present a new Pao2 imaging scheme, using parallel accelerated MRI, which significantly reduces measurement error. The proposed Pao2 mapping scheme was computer-simulated and was tested on both phantoms and five human subjects. Where possible, correspondence between actual local oxygen concentration and derived values was assessed for both bias (deviation from the true mean) and imaging artifact (deviation from the true spatial distribution). Phantom experiments demonstrated a significantly reduced coefficient of variation using the accelerated scheme. Simulation results support this observation and predict that correspondence between the true spatial distribution and the derived map is always superior using the accelerated scheme, although the improvement becomes less significant as the signal-to-noise ratio increases. Paired measurements in the human subjects, comparing accelerated and fully sampled schemes, show a reduced Pao2 distribution width for 41 of 46 slices. In contrast to proton MRI, acceleration of hyperpolarized imaging has no signal-to-noise penalty; its use in Pao2 measurement is therefore always beneficial. Comparison of multiple schemes shows that the benefit arises from a longer time-base during which oxygen-induced depolarization modifies the signal strength. Demonstration of the accelerated technique in human studies shows the feasibility of the method and suggests that measurement error is reduced here as well, particularly at low signal-to-noise levels. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.
Winterdahl, Michael; Sørensen, Michael; Keiding, Susanne; Mortensen, Frank V.; Alstrup, Aage K. O.; Hansen, Søren B.; Munk, Ole L.
2012-01-01
Objective To determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates. Materials and Methods Ten anesthetized 40-kg pigs underwent DCE-CT during periods of normocapnia (normal flow), hypocapnia (decreased flow), and hypercapnia (increased flow), which was induced by adjusting the ventilation. Reference blood flows in HA and PV were measured continuously by surgically-placed ultrasound transit-time flowmeters. For each capnic condition, the DCE-CT estimated absolute hepatic blood perfusion from HA and PV were calculated using the slope method and compared with flowmeter based absolute measurements of hepatic perfusions and relative errors were analyzed. Results The relative errors (mean±SEM) of the DCE-CT based perfusion estimates were −21±23% for HA and 81±31% for PV (normocapnia), 9±23% for HA and 92±42% for PV (hypocapnia), and 64±28% for HA and −2±20% for PV (hypercapnia). The mean relative errors for HA were not significantly different from zero during hypo- and normocapnia, and the DCE-CT slope method could detect relative changes in HA perfusion between scans. Infusion of contrast agent led to significantly increased hepatic blood perfusion, which biased the PV perfusion estimates. Conclusions Using the DCE-CT slope method, HA perfusion estimates were accurate at low and normal flow rates whereas PV perfusion estimates were inaccurate and imprecise. At high flow rate, both HA perfusion estimates were significantly biased. PMID:22836307
A crowdsourcing workflow for extracting chemical-induced disease relations from free text
Li, Tong Shu; Bravo, Àlex; Furlong, Laura I.; Good, Benjamin M.; Su, Andrew I.
2016-01-01
Relations between chemicals and diseases are one of the most queried biomedical interactions. Although expert manual curation is the standard method for extracting these relations from the literature, it is expensive and impractical to apply to large numbers of documents, and therefore alternative methods are required. We describe here a crowdsourcing workflow for extracting chemical-induced disease relations from free text as part of the BioCreative V Chemical Disease Relation challenge. Five non-expert workers on the CrowdFlower platform were shown each potential chemical-induced disease relation highlighted in the original source text and asked to make binary judgments about whether the text supported the relation. Worker responses were aggregated through voting, and relations receiving four or more votes were predicted as true. On the official evaluation dataset of 500 PubMed abstracts, the crowd attained a 0.505 F-score (0.475 precision, 0.540 recall), with a maximum theoretical recall of 0.751 due to errors with named entity recognition. The total crowdsourcing cost was $1290.67 ($2.58 per abstract) and took a total of 7 h. A qualitative error analysis revealed that 46.66% of sampled errors were due to task limitations and gold standard errors, indicating that performance can still be improved. All code and results are publicly available at https://github.com/SuLab/crowd_cid_relex Database URL: https://github.com/SuLab/crowd_cid_relex PMID:27087308
Ruschke, Stefan; Eggers, Holger; Kooijman, Hendrik; Diefenbach, Maximilian N; Baum, Thomas; Haase, Axel; Rummeny, Ernst J; Hu, Houchun H; Karampinos, Dimitrios C
2017-09-01
To propose a phase error correction scheme for monopolar time-interleaved multi-echo gradient echo water-fat imaging that allows accurate and robust complex-based quantification of the proton density fat fraction (PDFF). A three-step phase correction scheme is proposed to address a) a phase term induced by echo misalignments that can be measured with a reference scan using reversed readout polarity, b) a phase term induced by the concomitant gradient field that can be predicted from the gradient waveforms, and c) a phase offset between time-interleaved echo trains. Simulations were carried out to characterize the concomitant gradient field-induced PDFF bias and the performance estimating the phase offset between time-interleaved echo trains. Phantom experiments and in vivo liver and thigh imaging were performed to study the relevance of each of the three phase correction steps on PDFF accuracy and robustness. The simulation, phantom, and in vivo results showed in agreement with the theory an echo time-dependent PDFF bias introduced by the three phase error sources. The proposed phase correction scheme was found to provide accurate PDFF estimation independent of the employed echo time combination. Complex-based time-interleaved water-fat imaging was found to give accurate and robust PDFF measurements after applying the proposed phase error correction scheme. Magn Reson Med 78:984-996, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Huang, Kuo-Chen; Wang, Hsiu-Feng; Chen, Chun-Ching
2010-06-01
Effects of shape, size, and chromaticity of stimuli on participants' errors when estimating the size of simultaneously presented standard and comparison stimuli were examined. 48 Taiwanese college students ages 20 to 24 years old (M = 22.3, SD = 1.3) participated. Analysis showed that the error for estimated size was significantly greater for those in the low-vision group than for those in the normal-vision and severe-myopia groups. The errors were significantly greater with green and blue stimuli than with red stimuli. Circular stimuli produced smaller mean errors than did square stimuli. The actual size of the standard stimulus significantly affected the error for estimated size. Errors for estimations using smaller sizes were significantly higher than when the sizes were larger. Implications of the results for graphics-based interface design, particularly when taking account of visually impaired users, are discussed.
Tsai, Karin; Wallis, Jonathan; Botvinick, Matthew
2013-01-01
Studies suggest that dopaminergic neurons report a unitary, global reward prediction error signal. However, learning in complex real-life tasks, in particular tasks that show hierarchical structure, requires multiple prediction errors that may coincide in time. We used functional neuroimaging to measure prediction error signals in humans performing such a hierarchical task involving simultaneous, uncorrelated prediction errors. Analysis of signals in a priori anatomical regions of interest in the ventral striatum and the ventral tegmental area indeed evidenced two simultaneous, but separable, prediction error signals corresponding to the two levels of hierarchy in the task. This result suggests that suitably designed tasks may reveal a more intricate pattern of firing in dopaminergic neurons. Moreover, the need for downstream separation of these signals implies possible limitations on the number of different task levels that we can learn about simultaneously. PMID:23536092
Takahashi, Yuji K.; Langdon, Angela J.; Niv, Yael; Schoenbaum, Geoffrey
2016-01-01
Summary Dopamine neurons signal reward prediction errors. This requires accurate reward predictions. It has been suggested that the ventral striatum provides these predictions. Here we tested this hypothesis by recording from putative dopamine neurons in the VTA of rats performing a task in which prediction errors were induced by shifting reward timing or number. In controls, the neurons exhibited error signals in response to both manipulations. However, dopamine neurons in rats with ipsilateral ventral striatal lesions exhibited errors only to changes in number and failed to respond to changes in timing of reward. These results, supported by computational modeling, indicate that predictions about the temporal specificity and the number of expected rewards are dissociable, and that dopaminergic prediction-error signals rely on the ventral striatum for the former but not the latter. PMID:27292535
A new methodology for vibration error compensation of optical encoders.
Lopez, Jesus; Artes, Mariano
2012-01-01
Optical encoders are sensors based on grating interference patterns. Tolerances inherent to the manufacturing process can induce errors in the position accuracy as the measurement signals stand apart from the ideal conditions. In case the encoder is working under vibrations, the oscillating movement of the scanning head is registered by the encoder system as a displacement, introducing an error into the counter to be added up to graduation, system and installation errors. Behavior improvement can be based on different techniques trying to compensate the error from measurement signals processing. In this work a new "ad hoc" methodology is presented to compensate the error of the encoder when is working under the influence of vibration. The methodology is based on fitting techniques to the Lissajous figure of the deteriorated measurement signals and the use of a look up table, giving as a result a compensation procedure in which a higher accuracy of the sensor is obtained.
Gaudio, Jennifer L; Snowdon, Charles T
2008-11-01
Animals living in stable home ranges have many potential cues to locate food. Spatial and color cues are important for wild Callitrichids (marmosets and tamarins). Field studies have assigned the highest priority to distal spatial cues for determining the location of food resources with color cues serving as a secondary cue to assess relative ripeness, once a food source is located. We tested two hypotheses with captive cotton-top tamarins: (a) Tamarins will demonstrate higher rates of initial learning when rewarded for attending to spatial cues versus color cues. (b) Tamarins will show higher rates of correct responses when transferred from color cues to spatial cues than from spatial cues to color cues. The results supported both hypotheses. Tamarins rewarded based on spatial location made significantly more correct choices and fewer errors than tamarins rewarded based on color cues during initial learning. Furthermore, tamarins trained on color cues showed significantly increased correct responses and decreased errors when cues were reversed to reward spatial cues. Subsequent reversal to color cues induced a regression in performance. For tamarins spatial cues appear more salient than color cues in a foraging task. (PsycINFO Database Record (c) 2008 APA, all rights reserved).
Prakash, Varuna; Koczmara, Christine; Savage, Pamela; Trip, Katherine; Stewart, Janice; McCurdie, Tara; Cafazzo, Joseph A; Trbovich, Patricia
2014-11-01
Nurses are frequently interrupted during medication verification and administration; however, few interventions exist to mitigate resulting errors, and the impact of these interventions on medication safety is poorly understood. The study objectives were to (A) assess the effects of interruptions on medication verification and administration errors, and (B) design and test the effectiveness of targeted interventions at reducing these errors. The study focused on medication verification and administration in an ambulatory chemotherapy setting. A simulation laboratory experiment was conducted to determine interruption-related error rates during specific medication verification and administration tasks. Interventions to reduce these errors were developed through a participatory design process, and their error reduction effectiveness was assessed through a postintervention experiment. Significantly more nurses committed medication errors when interrupted than when uninterrupted. With use of interventions when interrupted, significantly fewer nurses made errors in verifying medication volumes contained in syringes (16/18; 89% preintervention error rate vs 11/19; 58% postintervention error rate; p=0.038; Fisher's exact test) and programmed in ambulatory pumps (17/18; 94% preintervention vs 11/19; 58% postintervention; p=0.012). The rate of error commission significantly decreased with use of interventions when interrupted during intravenous push (16/18; 89% preintervention vs 6/19; 32% postintervention; p=0.017) and pump programming (7/18; 39% preintervention vs 1/19; 5% postintervention; p=0.017). No statistically significant differences were observed for other medication verification tasks. Interruptions can lead to medication verification and administration errors. Interventions were highly effective at reducing unanticipated errors of commission in medication administration tasks, but showed mixed effectiveness at reducing predictable errors of detection in medication verification tasks. These findings can be generalised and adapted to mitigate interruption-related errors in other settings where medication verification and administration are required. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Prakash, Varuna; Koczmara, Christine; Savage, Pamela; Trip, Katherine; Stewart, Janice; McCurdie, Tara; Cafazzo, Joseph A; Trbovich, Patricia
2014-01-01
Background Nurses are frequently interrupted during medication verification and administration; however, few interventions exist to mitigate resulting errors, and the impact of these interventions on medication safety is poorly understood. Objective The study objectives were to (A) assess the effects of interruptions on medication verification and administration errors, and (B) design and test the effectiveness of targeted interventions at reducing these errors. Methods The study focused on medication verification and administration in an ambulatory chemotherapy setting. A simulation laboratory experiment was conducted to determine interruption-related error rates during specific medication verification and administration tasks. Interventions to reduce these errors were developed through a participatory design process, and their error reduction effectiveness was assessed through a postintervention experiment. Results Significantly more nurses committed medication errors when interrupted than when uninterrupted. With use of interventions when interrupted, significantly fewer nurses made errors in verifying medication volumes contained in syringes (16/18; 89% preintervention error rate vs 11/19; 58% postintervention error rate; p=0.038; Fisher's exact test) and programmed in ambulatory pumps (17/18; 94% preintervention vs 11/19; 58% postintervention; p=0.012). The rate of error commission significantly decreased with use of interventions when interrupted during intravenous push (16/18; 89% preintervention vs 6/19; 32% postintervention; p=0.017) and pump programming (7/18; 39% preintervention vs 1/19; 5% postintervention; p=0.017). No statistically significant differences were observed for other medication verification tasks. Conclusions Interruptions can lead to medication verification and administration errors. Interventions were highly effective at reducing unanticipated errors of commission in medication administration tasks, but showed mixed effectiveness at reducing predictable errors of detection in medication verification tasks. These findings can be generalised and adapted to mitigate interruption-related errors in other settings where medication verification and administration are required. PMID:24906806
NASA Astrophysics Data System (ADS)
Yang, Yuxiao; Shanechi, Maryam M.
2016-12-01
Objective. Design of closed-loop anesthetic delivery (CLAD) systems is an important topic, particularly for medically induced coma, which needs to be maintained for long periods. Current CLADs for medically induced coma require a separate offline experiment for model parameter estimation, which causes interruption in treatment and is difficult to perform. Also, CLADs may exhibit bias due to inherent time-variation and non-stationarity, and may have large infusion rate variations at steady state. Finally, current CLADs lack theoretical performance guarantees. We develop the first adaptive CLAD for medically induced coma, which addresses these limitations. Further, we extend our adaptive system to be generalizable to other states of anesthesia. Approach. We designed general parametric pharmacodynamic, pharmacokinetic and neural observation models with associated guidelines, and derived a novel adaptive controller. We further penalized large steady-state drug infusion rate variations in the controller. We derived theoretical guarantees that the adaptive system has zero steady-state bias. Using simulations that resembled real time-varying and noisy environments, we tested the closed-loop system for control of two different anesthetic states, burst suppression in medically induced coma and unconsciousness in general anesthesia. Main results. In 1200 simulations, the adaptive system achieved precise control of both anesthetic states despite non-stationarity, time-variation, noise, and no initial parameter knowledge. In both cases, the adaptive system performed close to a baseline system that knew the parameters exactly. In contrast, a non-adaptive system resulted in large steady-state bias and error. The adaptive system also resulted in significantly smaller steady-state infusion rate variations compared to prior systems. Significance. These results have significant implications for clinically viable CLAD design for a wide range of anesthetic states, with potential cost-saving and therapeutic benefits.
Structural deformation upon protein-protein interaction: A structural alphabet approach
Martin, Juliette; Regad, Leslie; Lecornet, Hélène; Camproux, Anne-Claude
2008-01-01
Background In a number of protein-protein complexes, the 3D structures of bound and unbound partners significantly differ, supporting the induced fit hypothesis for protein-protein binding. Results In this study, we explore the induced fit modifications on a set of 124 proteins available in both bound and unbound forms, in terms of local structure. The local structure is described thanks to a structural alphabet of 27 structural letters that allows a detailed description of the backbone. Using a control set to distinguish induced fit from experimental error and natural protein flexibility, we show that the fraction of structural letters modified upon binding is significantly greater than in the control set (36% versus 28%). This proportion is even greater in the interface regions (41%). Interface regions preferentially involve coils. Our analysis further reveals that some structural letters in coil are not favored in the interface. We show that certain structural letters in coil are particularly subject to modifications at the interface, and that the severity of structural change also varies. These information are used to derive a structural letter substitution matrix that summarizes the local structural changes observed in our data set. We also illustrate the usefulness of our approach to identify common binding motifs in unrelated proteins. Conclusion Our study provides qualitative information about induced fit. These results could be of help for flexible docking. PMID:18307769
Structural deformation upon protein-protein interaction: a structural alphabet approach.
Martin, Juliette; Regad, Leslie; Lecornet, Hélène; Camproux, Anne-Claude
2008-02-28
In a number of protein-protein complexes, the 3D structures of bound and unbound partners significantly differ, supporting the induced fit hypothesis for protein-protein binding. In this study, we explore the induced fit modifications on a set of 124 proteins available in both bound and unbound forms, in terms of local structure. The local structure is described thanks to a structural alphabet of 27 structural letters that allows a detailed description of the backbone. Using a control set to distinguish induced fit from experimental error and natural protein flexibility, we show that the fraction of structural letters modified upon binding is significantly greater than in the control set (36% versus 28%). This proportion is even greater in the interface regions (41%). Interface regions preferentially involve coils. Our analysis further reveals that some structural letters in coil are not favored in the interface. We show that certain structural letters in coil are particularly subject to modifications at the interface, and that the severity of structural change also varies. These information are used to derive a structural letter substitution matrix that summarizes the local structural changes observed in our data set. We also illustrate the usefulness of our approach to identify common binding motifs in unrelated proteins. Our study provides qualitative information about induced fit. These results could be of help for flexible docking.
Research on effects of phase error in phase-shifting interferometer
NASA Astrophysics Data System (ADS)
Wang, Hongjun; Wang, Zhao; Zhao, Hong; Tian, Ailing; Liu, Bingcai
2007-12-01
Referring to phase-shifting interferometry technology, the phase shifting error from the phase shifter is the main factor that directly affects the measurement accuracy of the phase shifting interferometer. In this paper, the resources and sorts of phase shifting error were introduction, and some methods to eliminate errors were mentioned. Based on the theory of phase shifting interferometry, the effects of phase shifting error were analyzed in detail. The Liquid Crystal Display (LCD) as a new shifter has advantage as that the phase shifting can be controlled digitally without any mechanical moving and rotating element. By changing coded image displayed on LCD, the phase shifting in measuring system was induced. LCD's phase modulation characteristic was analyzed in theory and tested. Based on Fourier transform, the effect model of phase error coming from LCD was established in four-step phase shifting interferometry. And the error range was obtained. In order to reduce error, a new error compensation algorithm was put forward. With this method, the error can be obtained by process interferogram. The interferogram can be compensated, and the measurement results can be obtained by four-step phase shifting interferogram. Theoretical analysis and simulation results demonstrate the feasibility of this approach to improve measurement accuracy.
Mismeasurement and the resonance of strong confounders: correlated errors.
Marshall, J R; Hastrup, J L; Ross, J S
1999-07-01
Confounding in epidemiology, and the limits of standard methods of control for an imperfectly measured confounder, have been understood for some time. However, most treatments of this problem are based on the assumption that errors of measurement in confounding and confounded variables are independent. This paper considers the situation in which a strong risk factor (confounder) and an inconsequential but suspected risk factor (confounded) are each measured with errors that are correlated; the situation appears especially likely to occur in the field of nutritional epidemiology. Error correlation appears to add little to measurement error as a source of bias in estimating the impact of a strong risk factor: it can add to, diminish, or reverse the bias induced by measurement error in estimating the impact of the inconsequential risk factor. Correlation of measurement errors can add to the difficulty involved in evaluating structures in which confounding and measurement error are present. In its presence, observed correlations among risk factors can be greater than, less than, or even opposite to the true correlations. Interpretation of multivariate epidemiologic structures in which confounding is likely requires evaluation of measurement error structures, including correlations among measurement errors.
Automated drug dispensing system reduces medication errors in an intensive care setting.
Chapuis, Claire; Roustit, Matthieu; Bal, Gaëlle; Schwebel, Carole; Pansu, Pascal; David-Tchouda, Sandra; Foroni, Luc; Calop, Jean; Timsit, Jean-François; Allenet, Benoît; Bosson, Jean-Luc; Bedouch, Pierrick
2010-12-01
We aimed to assess the impact of an automated dispensing system on the incidence of medication errors related to picking, preparation, and administration of drugs in a medical intensive care unit. We also evaluated the clinical significance of such errors and user satisfaction. Preintervention and postintervention study involving a control and an intervention medical intensive care unit. Two medical intensive care units in the same department of a 2,000-bed university hospital. Adult medical intensive care patients. After a 2-month observation period, we implemented an automated dispensing system in one of the units (study unit) chosen randomly, with the other unit being the control. The overall error rate was expressed as a percentage of total opportunities for error. The severity of errors was classified according to National Coordinating Council for Medication Error Reporting and Prevention categories by an expert committee. User satisfaction was assessed through self-administered questionnaires completed by nurses. A total of 1,476 medications for 115 patients were observed. After automated dispensing system implementation, we observed a reduced percentage of total opportunities for error in the study compared to the control unit (13.5% and 18.6%, respectively; p<.05); however, no significant difference was observed before automated dispensing system implementation (20.4% and 19.3%, respectively; not significant). Before-and-after comparisons in the study unit also showed a significantly reduced percentage of total opportunities for error (20.4% and 13.5%; p<.01). An analysis of detailed opportunities for error showed a significant impact of the automated dispensing system in reducing preparation errors (p<.05). Most errors caused no harm (National Coordinating Council for Medication Error Reporting and Prevention category C). The automated dispensing system did not reduce errors causing harm. Finally, the mean for working conditions improved from 1.0±0.8 to 2.5±0.8 on the four-point Likert scale. The implementation of an automated dispensing system reduced overall medication errors related to picking, preparation, and administration of drugs in the intensive care unit. Furthermore, most nurses favored the new drug dispensation organization.
NASA Astrophysics Data System (ADS)
Werdiger, M.; Arad, B.; Moshe, E.; Eliezer, S.
1995-02-01
A simple optical method for measurements of high-irradiance (3×1013 W cm-2) laser-induced shock waves is described. The shock wave velocity (~13 km s-1) was measured with an error not exceeding 5%. The laser-induced one-to-two-dimensional (1D-to-2D) shock wave transition was studied.
Chronic low-dose ultraviolet-induced mutagenesis in nucleotide excision repair-deficient cells.
Haruta, Nami; Kubota, Yoshino; Hishida, Takashi
2012-09-01
UV radiation induces two major types of DNA lesions, cyclobutane pyrimidine dimers (CPDs) and 6-4 pyrimidine-pyrimidine photoproducts, which are both primarily repaired by nucleotide excision repair (NER). Here, we investigated how chronic low-dose UV (CLUV)-induced mutagenesis occurs in rad14Δ NER-deficient yeast cells, which lack the yeast orthologue of human xeroderma pigmentosum A (XPA). The results show that rad14Δ cells have a marked increase in CLUV-induced mutations, most of which are C→T transitions in the template strand for transcription. Unexpectedly, many of the CLUV-induced C→T mutations in rad14Δ cells are dependent on translesion synthesis (TLS) DNA polymerase η, encoded by RAD30, despite its previously established role in error-free TLS. Furthermore, we demonstrate that deamination of cytosine-containing CPDs contributes to CLUV-induced mutagenesis. Taken together, these results uncover a novel role for Polη in the induction of C→T transitions through deamination of cytosine-containing CPDs in CLUV-exposed NER deficient cells. More generally, our data suggest that Polη can act as both an error-free and a mutagenic DNA polymerase, depending on whether the NER pathway is available to efficiently repair damaged templates.
Blumenfeld, Philip; Hata, Nobuhiko; DiMaio, Simon; Zou, Kelly; Haker, Steven; Fichtinger, Gabor; Tempany, Clare M C
2007-09-01
To quantify needle placement accuracy of magnetic resonance image (MRI)-guided core needle biopsy of the prostate. A total of 10 biopsies were performed with 18-gauge (G) core biopsy needle via a percutaneous transperineal approach. Needle placement error was assessed by comparing the coordinates of preplanned targets with the needle tip measured from the intraprocedural coherent gradient echo images. The source of these errors was subsequently investigated by measuring displacement caused by needle deflection and needle susceptibility artifact shift in controlled phantom studies. Needle placement error due to misalignment of the needle template guide was also evaluated. The mean and standard deviation (SD) of errors in targeted biopsies was 6.5 +/- 3.5 mm. Phantom experiments showed significant placement error due to needle deflection with a needle with an asymmetrically beveled tip (3.2-8.7 mm depending on tissue type) but significantly smaller error with a symmetrical bevel (0.6-1.1 mm). Needle susceptibility artifacts observed a shift of 1.6 +/- 0.4 mm from the true needle axis. Misalignment of the needle template guide contributed an error of 1.5 +/- 0.3 mm. Needle placement error was clinically significant in MRI-guided biopsy for diagnosis of prostate cancer. Needle placement error due to needle deflection was the most significant cause of error, especially for needles with an asymmetrical bevel. (c) 2007 Wiley-Liss, Inc.
Moors, Pieter
2015-01-01
In a recent functional magnetic resonance imaging study, Kok and de Lange (2014) observed that BOLD activity for a Kanizsa illusory shape stimulus, in which pacmen-like inducers elicit an illusory shape percept, was either enhanced or suppressed relative to a nonillusory control configuration depending on whether the spatial profile of BOLD activity in early visual cortex was related to the illusory shape or the inducers, respectively. The authors argued that these findings fit well with the predictive coding framework, because top-down predictions related to the illusory shape are not met with bottom-up sensory input and hence the feedforward error signal is enhanced. Conversely, for the inducing elements, there is a match between top-down predictions and input, leading to a decrease in error. Rather than invoking predictive coding as the explanatory framework, the suppressive effect related to the inducers might be caused by neural adaptation to perceptually stable input due to the trial sequence used in the experiment.
Analysis of the PLL phase error in presence of simulated ionospheric scintillation events
NASA Astrophysics Data System (ADS)
Forte, B.
2012-01-01
The functioning of standard phase locked loops (PLL), including those used to track radio signals from Global Navigation Satellite Systems (GNSS), is based on a linear approximation which holds in presence of small phase errors. Such an approximation represents a reasonable assumption in most of the propagation channels. However, in presence of a fading channel the phase error may become large, making the linear approximation no longer valid. The PLL is then expected to operate in a non-linear regime. As PLLs are generally designed and expected to operate in their linear regime, whenever the non-linear regime comes into play, they will experience a serious limitation in their capability to track the corresponding signals. The phase error and the performance of a typical PLL embedded into a commercial multiconstellation GNSS receiver were analyzed in presence of simulated ionospheric scintillation. Large phase errors occurred during scintillation-induced signal fluctuations although cycle slips only occurred during the signal re-acquisition after a loss of lock. Losses of lock occurred whenever the signal faded below the minimumC/N0threshold allowed for tracking. The simulations were performed for different signals (GPS L1C/A, GPS L2C, GPS L5 and Galileo L1). L5 and L2C proved to be weaker than L1. It appeared evident that the conditions driving the PLL phase error in the specific case of GPS receivers in presence of scintillation-induced signal perturbations need to be evaluated in terms of the combination of the minimumC/N0 tracking threshold, lock detector thresholds, possible cycle slips in the tracking PLL and accuracy of the observables (i.e. the error propagation onto the observables stage).
Errors as a Means of Reducing Impulsive Food Choice.
Sellitto, Manuela; di Pellegrino, Giuseppe
2016-06-05
Nowadays, the increasing incidence of eating disorders due to poor self-control has given rise to increased obesity and other chronic weight problems, and ultimately, to reduced life expectancy. The capacity to refrain from automatic responses is usually high in situations in which making errors is highly likely. The protocol described here aims at reducing imprudent preference in women during hypothetical intertemporal choices about appetitive food by associating it with errors. First, participants undergo an error task where two different edible stimuli are associated with two different error likelihoods (high and low). Second, they make intertemporal choices about the two edible stimuli, separately. As a result, this method decreases the discount rate for future amounts of the edible reward that cued higher error likelihood, selectively. This effect is under the influence of the self-reported hunger level. The present protocol demonstrates that errors, well known as motivationally salient events, can induce the recruitment of cognitive control, thus being ultimately useful in reducing impatient choices for edible commodities.
Errors as a Means of Reducing Impulsive Food Choice
Sellitto, Manuela; di Pellegrino, Giuseppe
2016-01-01
Nowadays, the increasing incidence of eating disorders due to poor self-control has given rise to increased obesity and other chronic weight problems, and ultimately, to reduced life expectancy. The capacity to refrain from automatic responses is usually high in situations in which making errors is highly likely. The protocol described here aims at reducing imprudent preference in women during hypothetical intertemporal choices about appetitive food by associating it with errors. First, participants undergo an error task where two different edible stimuli are associated with two different error likelihoods (high and low). Second, they make intertemporal choices about the two edible stimuli, separately. As a result, this method decreases the discount rate for future amounts of the edible reward that cued higher error likelihood, selectively. This effect is under the influence of the self-reported hunger level. The present protocol demonstrates that errors, well known as motivationally salient events, can induce the recruitment of cognitive control, thus being ultimately useful in reducing impatient choices for edible commodities. PMID:27341281
Booth, Rachelle; Sturgess, Emma; Taberner-Stokes, Alison; Peters, Mark
2012-11-01
To establish the baseline prescribing error rate in a tertiary paediatric intensive care unit (PICU) and to determine the impact of a zero tolerance prescribing (ZTP) policy incorporating a dedicated prescribing area and daily feedback of prescribing errors. A prospective, non-blinded, observational study was undertaken in a 12-bed tertiary PICU over a period of 134 weeks. Baseline prescribing error data were collected on weekdays for all patients for a period of 32 weeks, following which the ZTP policy was introduced. Daily error feedback was introduced after a further 12 months. Errors were sub-classified as 'clinical', 'non-clinical' and 'infusion prescription' errors and the effects of interventions considered separately. The baseline combined prescribing error rate was 892 (95 % confidence interval (CI) 765-1,019) errors per 1,000 PICU occupied bed days (OBDs), comprising 25.6 % clinical, 44 % non-clinical and 30.4 % infusion prescription errors. The combined interventions of ZTP plus daily error feedback were associated with a reduction in the combined prescribing error rate to 447 (95 % CI 389-504) errors per 1,000 OBDs (p < 0.0001), an absolute risk reduction of 44.5 % (95 % CI 40.8-48.0 %). Introduction of the ZTP policy was associated with a significant decrease in clinical and infusion prescription errors, while the introduction of daily error feedback was associated with a significant reduction in non-clinical prescribing errors. The combined interventions of ZTP and daily error feedback were associated with a significant reduction in prescribing errors in the PICU, in line with Department of Health requirements of a 40 % reduction within 5 years.
NASA Astrophysics Data System (ADS)
Wozniak, Kaitlin T.; Germer, Thomas A.; Butler, Sam C.; Brooks, Daniel R.; Huxlin, Krystel R.; Ellis, Jonathan D.
2018-02-01
We present measurements of light scatter induced by a new ultrafast laser technique being developed for laser refractive correction in transparent ophthalmic materials such as cornea, contact lenses, and/or intraocular lenses. In this new technique, called intra-tissue refractive index shaping (IRIS), a 405 nm femtosecond laser is focused and scanned below the corneal surface, inducing a spatially-varying refractive index change that corrects vision errors. In contrast with traditional laser correction techniques, such as laser in-situ keratomileusis (LASIK) or photorefractive keratectomy (PRK), IRIS does not operate via photoablation, but rather changes the refractive index of transparent materials such as cornea and hydrogels. A concern with any laser eye correction technique is additional scatter induced by the process, which can adversely affect vision, especially at night. The goal of this investigation is to identify sources of scatter induced by IRIS and to mitigate possible effects on visual performance in ophthalmic applications. Preliminary light scattering measurements on patterns written into hydrogel showed four sources of scatter, differentiated by distinct behaviors: (1) scattering from scanned lines; (2) scattering from stitching errors, resulting from adjacent scanning fields not being aligned to one another; (3) diffraction from Fresnel zone discontinuities; and (4) long-period variations in the scans that created distinct diffraction peaks, likely due to inconsistent line spacing in the writing instrument. By knowing the nature of these different scattering errors, it will now be possible to modify and optimize the design of IRIS structures to mitigate potential deficits in visual performance in human clinical trials.
Resident Work Hour Restrictions and Change Management: A Cautionary Tale.
Fang, Z Amy; Hudson, Darren
2015-01-01
Residents are a significant part of coverage in many hospitals. Resident associations are negotiating work hour limits to prevent fatigue-induced medical errors. Our intensive care unit experienced an unexpected resident shortage and used the opportunity to trial a shift schedule for one month. Post-surveys were sent to nurses, attending physicians and residents to evaluate the effects on staff interactions, patient safety and education quality. The trial was clearly a failure on all fronts. Work hour restrictions are a reality in medical education, and administrators need to start considering alternative staffing models and discussing alternative schedules with their medicine faculty.
NASA Astrophysics Data System (ADS)
Genberg, Victor L.; Michels, Gregory J.
2017-08-01
The ultimate design goal of an optical system subjected to dynamic loads is to minimize system level wavefront error (WFE). In random response analysis, system WFE is difficult to predict from finite element results due to the loss of phase information. In the past, the use of ystem WFE was limited by the difficulty of obtaining a linear optics model. In this paper, an automated method for determining system level WFE using a linear optics model is presented. An error estimate is included in the analysis output based on fitting errors of mode shapes. The technique is demonstrated by example with SigFit, a commercially available tool integrating mechanical analysis with optical analysis.
Bit-error rate for free-space adaptive optics laser communications.
Tyson, Robert K
2002-04-01
An analysis of adaptive optics compensation for atmospheric-turbulence-induced scintillation is presented with the figure of merit being the laser communications bit-error rate. The formulation covers weak, moderate, and strong turbulence; on-off keying; and amplitude-shift keying, over horizontal propagation paths or on a ground-to-space uplink or downlink. The theory shows that under some circumstances the bit-error rate can be improved by a few orders of magnitude with the addition of adaptive optics to compensate for the scintillation. Low-order compensation (less than 40 Zernike modes) appears to be feasible as well as beneficial for reducing the bit-error rate and increasing the throughput of the communication link.
Evaluation of Parenteral Nutrition Errors in an Era of Drug Shortages.
Storey, Michael A; Weber, Robert J; Besco, Kelly; Beatty, Stuart; Aizawa, Kumiko; Mirtallo, Jay M
2016-04-01
Ingredient shortages have forced many organizations to change practices or use unfamiliar ingredients, which creates potential for error. Parenteral nutrition (PN) has been significantly affected, as every ingredient in PN has been impacted in recent years. Ingredient errors involving PN that were reported to the national anonymous MedMARx database between May 2009 and April 2011 were reviewed. Errors were categorized by ingredient, node, and severity. Categorization was validated by experts in medication safety and PN. A timeline of PN ingredient shortages was developed and compared with the PN errors to determine if events correlated with an ingredient shortage. This information was used to determine the prevalence and change in harmful PN errors during periods of shortage, elucidating whether a statistically significant difference exists in errors during shortage as compared with a control period (ie, no shortage). There were 1311 errors identified. Nineteen errors were associated with harm. Fat emulsions and electrolytes were the PN ingredients most frequently associated with error. Insulin was the ingredient most often associated with patient harm. On individual error review, PN shortages were described in 13 errors, most of which were associated with intravenous fat emulsions; none were associated with harm. There was no correlation of drug shortages with the frequency of PN errors. Despite the significant impact that shortages have had on the PN use system, no adverse impact on patient safety could be identified from these reported PN errors. © 2015 American Society for Parenteral and Enteral Nutrition.
Radiation Tests on 2Gb NAND Flash Memories
NASA Technical Reports Server (NTRS)
Nguyen, Duc N.; Guertin, Steven M.; Patterson, J. D.
2006-01-01
We report on SEE and TID tests of highly scaled Samsung 2Gbits flash memories. Both in-situ and biased interval irradiations were used to characterize the response of the total accumulated dose failures. The radiation-induced failures can be categorized as followings: single event upset (SEU) read errors in biased and unbiased modes, write errors, and single-event-functional-interrupt (SEFI) failures.
NASA Astrophysics Data System (ADS)
Li, Xiongwei; Wang, Zhe; Lui, Siu-Lung; Fu, Yangting; Li, Zheng; Liu, Jianming; Ni, Weidou
2013-10-01
A bottleneck of the wide commercial application of laser-induced breakdown spectroscopy (LIBS) technology is its relatively high measurement uncertainty. A partial least squares (PLS) based normalization method was proposed to improve pulse-to-pulse measurement precision for LIBS based on our previous spectrum standardization method. The proposed model utilized multi-line spectral information of the measured element and characterized the signal fluctuations due to the variation of plasma characteristic parameters (plasma temperature, electron number density, and total number density) for signal uncertainty reduction. The model was validated by the application of copper concentration prediction in 29 brass alloy samples. The results demonstrated an improvement on both measurement precision and accuracy over the generally applied normalization as well as our previously proposed simplified spectrum standardization method. The average relative standard deviation (RSD), average of the standard error (error bar), the coefficient of determination (R2), the root-mean-square error of prediction (RMSEP), and average value of the maximum relative error (MRE) were 1.80%, 0.23%, 0.992, 1.30%, and 5.23%, respectively, while those for the generally applied spectral area normalization were 3.72%, 0.71%, 0.973, 1.98%, and 14.92%, respectively.
Alexeeff, Stacey E; Carroll, Raymond J; Coull, Brent
2016-04-01
Spatial modeling of air pollution exposures is widespread in air pollution epidemiology research as a way to improve exposure assessment. However, there are key sources of exposure model uncertainty when air pollution is modeled, including estimation error and model misspecification. We examine the use of predicted air pollution levels in linear health effect models under a measurement error framework. For the prediction of air pollution exposures, we consider a universal Kriging framework, which may include land-use regression terms in the mean function and a spatial covariance structure for the residuals. We derive the bias induced by estimation error and by model misspecification in the exposure model, and we find that a misspecified exposure model can induce asymptotic bias in the effect estimate of air pollution on health. We propose a new spatial simulation extrapolation (SIMEX) procedure, and we demonstrate that the procedure has good performance in correcting this asymptotic bias. We illustrate spatial SIMEX in a study of air pollution and birthweight in Massachusetts. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Borycki, Elizabeth M; Kushniruk, Andre W; Kuwata, Shigeki; Kannry, Joseph
2011-01-01
Electronic health records (EHRs) promise to improve and streamline healthcare through electronic entry and retrieval of patient data. Furthermore, based on a number of studies showing their positive benefits, they promise to reduce medical error and make healthcare safer. However, a growing body of literature has clearly documented that if EHRS are not designed properly and with usability as an important goal in their design, rather than reducing error, EHR deployment has the potential to actually increase medical error. In this paper we describe our approach to engineering (and reengineering) EHRs in order to increase their beneficial potential while at the same time improving their safety. The approach described in this paper involves an integration of the methods of usability analysis with video analysis of end users interacting with EHR systems and extends the evaluation of the usability of EHRs to include the assessment of the impact of these systems on work practices. Using clinical simulations, we analyze human-computer interaction in real healthcare settings (in a portable, low-cost and high fidelity manner) and include both artificial and naturalistic data collection to identify potential usability problems and sources of technology-induced error prior to widespread system release. Two case studies where the methods we have developed and refined have been applied at different levels of user-computer interaction are described.
The role of the right superior temporal gyrus in stimulus-centered spatial processing.
Shah-Basak, Priyanka P; Chen, Peii; Caulfield, Kevin; Medina, Jared; Hamilton, Roy H
2018-05-01
Although emerging neuropsychological evidence supports the involvement of temporal areas, and in particular the right superior temporal gyrus (STG), in allocentric neglect deficits, the role of STG in healthy spatial processing remains elusive. While several functional brain imaging studies have demonstrated involvement of the STG in tasks involving explicit stimulus-centered judgments, prior rTMS studies targeting the right STG did not find the expected neglect-like rightward bias in size judgments using the conventional landmark task. The objective of the current study was to investigate whether disruption of the right STG using inhibitory repetitive transcranial magnetic stimulation (rTMS) could impact stimulus-centered, allocentric spatial processing in healthy individuals. A lateralized version of the landmark task was developed to accentuate the dissociation between viewer-centered and stimulus-centered reference frames. We predicted that inhibiting activity in the right STG would decrease accuracy because of induced rightward bias centered on the line stimulus irrespective of its viewer-centered or egocentric locations. Eleven healthy, right-handed adults underwent the lateralized landmark task. After viewing each stimulus, participants had to judge whether the line was bisected, or whether the left (left-long trials) or the right segment (right-long trials) of the line was longer. Participants repeated the task before (pre-rTMS) and after (post-rTMS) receiving 20 min of 1 Hz rTMS over the right STG, the right supramarginal gyrus (SMG), and the vertex (a control site) during three separate visits. Linear mixed models for binomial data were generated with either accuracy or judgment errors as dependent variables, to compare 1) performance across trial types (bisection, non-bisection), and 2) pre- vs. post-rTMS performance between the vertex and the STG and the vertex and the SMG. Line eccentricity (z = 4.31, p < 0.0001) and line bisection (z = 5.49, p < 0.0001) were significant predictors of accuracy. In the models comparing the effects of rTMS, a significant two-way interaction with STG (z = -3.09, p = 0.002) revealed a decrease in accuracy of 9.5% and an increase in errors of the right-long type by 10.7% on bisection trials, in both left and right viewer-centered locations. No significant changes in leftward errors were found. These findings suggested an induced stimulus-centered rightward bias in our participants after STG stimulation. Notably, accuracy or errors were not influenced by SMG stimulation compared to vertex. In line with our predictions, the findings provide compelling evidence for right STG's involvement in healthy stimulus-centered spatial processing. Copyright © 2018 Elsevier Ltd. All rights reserved.
Global Precipitation Measurement Mission Launch and Commissioning
NASA Technical Reports Server (NTRS)
Davis, Nikesha; DeWeese, Keith; Vess, Melissa; O'Donnell, James R., Jr.; Welter, Gary
2015-01-01
During launch and early operation of the Global Precipitation Measurement (GPM) Mission, the Guidance, Navigation, and Control (GN&C) analysis team encountered four main on-orbit anomalies. These include: (1) unexpected shock from Solar Array deployment, (2) momentum buildup from the Magnetic Torquer Bars (MTBs) phasing errors, (3) transition into Safehold due to albedo induced Course Sun Sensor (CSS) anomaly, and (4) a flight software error that could cause a Safehold transition due to a Star Tracker occultation. This paper will discuss ways GN&C engineers identified the anomalies and tracked down the root causes. Flight data and GN&C on-board models will be shown to illustrate how each of these anomalies were investigated and mitigated before causing any harm to the spacecraft. On May 29, 2014, GPM was handed over to the Mission Flight Operations Team after a successful commissioning period. Currently, GPM is operating nominally on orbit, collecting meaningful scientific data that will significantly improve our understanding of the Earth's climate and water cycle.
POCS-enhanced correction of motion artifacts in parallel MRI.
Samsonov, Alexey A; Velikina, Julia; Jung, Youngkyoo; Kholmovski, Eugene G; Johnson, Chris R; Block, Walter F
2010-04-01
A new method for correction of MRI motion artifacts induced by corrupted k-space data, acquired by multiple receiver coils such as phased arrays, is presented. In our approach, a projections onto convex sets (POCS)-based method for reconstruction of sensitivity encoded MRI data (POCSENSE) is employed to identify corrupted k-space samples. After the erroneous data are discarded from the dataset, the artifact-free images are restored from the remaining data using coil sensitivity profiles. The error detection and data restoration are based on informational redundancy of phased-array data and may be applied to full and reduced datasets. An important advantage of the new POCS-based method is that, in addition to multicoil data redundancy, it can use a priori known properties about the imaged object for improved MR image artifact correction. The use of such information was shown to improve significantly k-space error detection and image artifact correction. The method was validated on data corrupted by simulated and real motion such as head motion and pulsatile flow.
Van Nguyen; Javaid, Abdul Q; Weitnauer, Mary Ann
2014-01-01
We introduce the Spectrum-averaged Harmonic Path (SHAPA) algorithm for estimation of heart rate (HR) and respiration rate (RR) with Impulse Radio Ultrawideband (IR-UWB) radar. Periodic movement of human torso caused by respiration and heart beat induces fundamental frequencies and their harmonics at the respiration and heart rates. IR-UWB enables capture of these spectral components and frequency domain processing enables a low cost implementation. Most existing methods of identifying the fundamental component either in frequency or time domain to estimate the HR and/or RR lead to significant error if the fundamental is distorted or cancelled by interference. The SHAPA algorithm (1) takes advantage of the HR harmonics, where there is less interference, and (2) exploits the information in previous spectra to achieve more reliable and robust estimation of the fundamental frequency in the spectrum under consideration. Example experimental results for HR estimation demonstrate how our algorithm eliminates errors caused by interference and produces 16% to 60% more valid estimates.
Intestinal helminths induce haematological changes in dogs from Jabalpur, India.
Qadir, S; Dixit, A K; Dixit, P; Sharma, R L
2011-12-01
The effect of canine intestinal helminths on the haematological profile of 200 dogs, of both sexes and variable age, visiting university veterinary clinics for routine examination was investigated. The dogs were assigned to parasitized (n = 39) and non-parasitized (n = 161) groups of animals. Coprological examination revealed a 19.5% prevalence of different species of the helminths. Of these animals, 10.25% had mixed infections with Ancylostoma caninum, Toxascaris spp. and Dipylidium caninum. The intensity of A. caninum infection was the highest, with mean egg counts of 951.43 (standard error 88.66), followed by Toxascaris 283.33 (standard error 116.81) and D. caninum. The parasitized animals had significantly lower levels of haemoglobin, packed cell volume and total erythrocyte counts than non-parasitized animals (P < 0.01). Values of other parameters, except for lymphocytes and eosinophils, were not different between the two groups. Analyses of the haematological profile revealed normocytic hypochromic anaemia in the parasitized group of animals.
Global Precipitation Measurement Mission Launch and Commissioning
NASA Technical Reports Server (NTRS)
Davis, Nikesha; Deweese, Keith; Vess, Missie; Welter, Gary; O'Donnell, James R., Jr.
2015-01-01
During launch and early operation of the Global Precipitation Measurement (GPM) Mission, the Guidance, Navigation and Control (GNC) analysis team encountered four main on orbit anomalies. These include: (1) unexpected shock from Solar Array deployment, (2) momentum buildup from the Magnetic Torquer Bars (MTBs) phasing errors, (3) transition into Safehold due to albedo-induced Course Sun Sensor (CSS) anomaly, and (4) a flight software error that could cause a Safehold transition due to a Star Tracker occultation. This paper will discuss ways GNC engineers identified and tracked down the root causes. Flight data and GNC on board models will be shown to illustrate how each of these anomalies were investigated and mitigated before causing any harm to the spacecraft. On May 29, 2014, GPM was handed over to the Mission Flight Operations Team after a successful commissioning period. Currently, GPM is operating nominally on orbit, collecting meaningful scientific data that will significantly improve our understanding of the Earth's climate and water cycle.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuster, J.J.; Stryker, J.A.; Demers, L.M.
The pathophysiology of chronic radiation-induced diarrhea was evaluated in 28 patients who had undergone pelvic irradiation for gynecologic neoplasms 2 to 7 years previously. Twenty-seven patients undergoing radiotherapy with techniques that did not require abdominal or pelvic irradiation served as controls. The glycine conjugates of cholic acid (GC) were measured in serum by radioimmunoassay. Fasting and 2 hr. pp GC levels for the pelvic irradiated patients were 11.0 +/- 11.1 (mean +/- SD) and 24.8 +/- 17.3 micrograms/dl. Fasting and 2 hr. pp GC levels for controls were 12.6 +/- 7.4 and 28.0 +/- 14.7. There were no significant differencesmore » in the post-prandial increases in serum GC between pelvic irradiated patients and controls (p = .23, Type II error probability = .13). There was also no significant difference in the 2 hr. pp and fasting GC ratio (p = .39). There was significant difference between the stool frequency (p less than .01) and the prevalence of diarrhea (p less than .02) between pelvic irradiated patients and controls. The data suggest that bile acid malabsorption due to ileal dysfunction is not an inevitable late complication of pelvic irradiation and is not the major determinant in the pathophysiology of chronic radiation-induced diarrhea.« less
NASA Astrophysics Data System (ADS)
Zheng, Fei; Zhu, Jiang
2017-04-01
How to design a reliable ensemble prediction strategy with considering the major uncertainties of a forecasting system is a crucial issue for performing an ensemble forecast. In this study, a new stochastic perturbation technique is developed to improve the prediction skills of El Niño-Southern Oscillation (ENSO) through using an intermediate coupled model. We first estimate and analyze the model uncertainties from the ensemble Kalman filter analysis results through assimilating the observed sea surface temperatures. Then, based on the pre-analyzed properties of model errors, we develop a zero-mean stochastic model-error model to characterize the model uncertainties mainly induced by the missed physical processes of the original model (e.g., stochastic atmospheric forcing, extra-tropical effects, Indian Ocean Dipole). Finally, we perturb each member of an ensemble forecast at each step by the developed stochastic model-error model during the 12-month forecasting process, and add the zero-mean perturbations into the physical fields to mimic the presence of missing processes and high-frequency stochastic noises. The impacts of stochastic model-error perturbations on ENSO deterministic predictions are examined by performing two sets of 21-yr hindcast experiments, which are initialized from the same initial conditions and differentiated by whether they consider the stochastic perturbations. The comparison results show that the stochastic perturbations have a significant effect on improving the ensemble-mean prediction skills during the entire 12-month forecasting process. This improvement occurs mainly because the nonlinear terms in the model can form a positive ensemble-mean from a series of zero-mean perturbations, which reduces the forecasting biases and then corrects the forecast through this nonlinear heating mechanism.
NASA Astrophysics Data System (ADS)
Hutchinson, G. L.; Livingston, G. P.; Healy, R. W.; Striegl, R. G.
2000-04-01
We employed a three-dimensional finite difference gas diffusion model to simulate the performance of chambers used to measure surface-atmosphere trace gas exchange. We found that systematic errors often result from conventional chamber design and deployment protocols, as well as key assumptions behind the estimation of trace gas exchange rates from observed concentration data. Specifically, our simulations showed that (1) when a chamber significantly alters atmospheric mixing processes operating near the soil surface, it also nearly instantaneously enhances or suppresses the postdeployment gas exchange rate, (2) any change resulting in greater soil gas diffusivity, or greater partitioning of the diffusing gas to solid or liquid soil fractions, increases the potential for chamber-induced measurement error, and (3) all such errors are independent of the magnitude, kinetics, and/or distribution of trace gas sources, but greater for trace gas sinks with the same initial absolute flux. Finally, and most importantly, we found that our results apply to steady state as well as non-steady-state chambers, because the slow rate of gas diffusion in soil inhibits recovery of the former from their initial non-steady-state condition. Over a range of representative conditions, the error in steady state chamber estimates of the trace gas flux varied from -30 to +32%, while estimates computed by linear regression from non-steady-state chamber concentrations were 2 to 31% too small. Although such errors are relatively small in comparison to the temporal and spatial variability characteristic of trace gas exchange, they bias the summary statistics for each experiment as well as larger scale trace gas flux estimates based on them.
Canovas, Carmen; Alarcon, Aixa; Rosén, Robert; Kasthurirangan, Sanjeev; Ma, Joseph J K; Koch, Douglas D; Piers, Patricia
2018-02-01
To assess the accuracy of toric intraocular lens (IOL) power calculations of a new algorithm that incorporates the effect of posterior corneal astigmatism (PCA). Abbott Medical Optics, Inc., Groningen, the Netherlands. Retrospective case report. In eyes implanted with toric IOLs, the exact vergence formula of the Tecnis toric calculator was used to predict refractive astigmatism from preoperative biometry, surgeon-estimated surgically induced astigmatism (SIA), and implanted IOL power, with and without including the new PCA algorithm. For each calculation method, the error in predicted refractive astigmatism was calculated as the vector difference between the prediction and the actual refraction. Calculations were also made using postoperative keratometry (K) values to eliminate the potential effect of incorrect SIA estimates. The study comprised 274 eyes. The PCA algorithm significantly reduced the centroid error in predicted refractive astigmatism (P < .001). With the PCA algorithm, the centroid error reduced from 0.50 @ 1 to 0.19 @ 3 when using preoperative K values and from 0.30 @ 0 to 0.02 @ 84 when using postoperative K values. Patients who had anterior corneal against-the-rule, with-the-rule, and oblique astigmatism had improvement with the PCA algorithm. In addition, the PCA algorithm reduced the median absolute error in all groups (P < .001). The use of the new PCA algorithm decreased the error in the prediction of residual refractive astigmatism in eyes implanted with toric IOLs. Therefore, the new PCA algorithm, in combination with an exact vergence IOL power calculation formula, led to an increased predictability of toric IOL power. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Hutchinson, G.L.; Livingston, G.P.; Healy, R.W.; Striegl, Robert G.
2000-01-01
We employed a three-dimensional finite difference gas diffusion model to simulate the performance of chambers used to measure surface-atmosphere tace gas exchange. We found that systematic errors often result from conventional chamber design and deployment protocols, as well as key assumptions behind the estimation of trace gas exchange rates from observed concentration data. Specifically, our simulationshowed that (1) when a chamber significantly alters atmospheric mixing processes operating near the soil surface, it also nearly instantaneously enhances or suppresses the postdeployment gas exchange rate, (2) any change resulting in greater soil gas diffusivity, or greater partitioning of the diffusing gas to solid or liquid soil fractions, increases the potential for chamber-induced measurement error, and (3) all such errors are independent of the magnitude, kinetics, and/or distribution of trace gas sources, but greater for trace gas sinks with the same initial absolute flux. Finally, and most importantly, we found that our results apply to steady state as well as non-steady-state chambers, because the slow rate of gas diffusion in soil inhibits recovery of the former from their initial non-steady-state condition. Over a range of representative conditions, the error in steady state chamber estimates of the trace gas flux varied from -30 to +32%, while estimates computed by linear regression from non-steadystate chamber concentrations were 2 to 31% too small. Although such errors are relatively small in comparison to the temporal and spatial variability characteristic of trace gas exchange, they bias the summary statistics for each experiment as well as larger scale trace gas flux estimates based on them.
Haptic spatial matching in near peripersonal space.
Kaas, Amanda L; Mier, Hanneke I van
2006-04-01
Research has shown that haptic spatial matching at intermanual distances over 60 cm is prone to large systematic errors. The error pattern has been explained by the use of reference frames intermediate between egocentric and allocentric coding. This study investigated haptic performance in near peripersonal space, i.e. at intermanual distances of 60 cm and less. Twelve blindfolded participants (six males and six females) were presented with two turn bars at equal distances from the midsagittal plane, 30 or 60 cm apart. Different orientations (vertical/horizontal or oblique) of the left bar had to be matched by adjusting the right bar to either a mirror symmetric (/ \\) or parallel (/ /) position. The mirror symmetry task can in principle be performed accurately in both an egocentric and an allocentric reference frame, whereas the parallel task requires an allocentric representation. Results showed that parallel matching induced large systematic errors which increased with distance. Overall error was significantly smaller in the mirror task. The task difference also held for the vertical orientation at 60 cm distance, even though this orientation required the same response in both tasks, showing a marked effect of task instruction. In addition, men outperformed women on the parallel task. Finally, contrary to our expectations, systematic errors were found in the mirror task, predominantly at 30 cm distance. Based on these findings, we suggest that haptic performance in near peripersonal space might be dominated by different mechanisms than those which come into play at distances over 60 cm. Moreover, our results indicate that both inter-individual differences and task demands affect task performance in haptic spatial matching. Therefore, we conclude that the study of haptic spatial matching in near peripersonal space might reveal important additional constraints for the specification of adequate models of haptic spatial performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Traci L.; Sharon, Keren, E-mail: tljohn@umich.edu
Until now, systematic errors in strong gravitational lens modeling have been acknowledged but have never been fully quantified. Here, we launch an investigation into the systematics induced by constraint selection. We model the simulated cluster Ares 362 times using random selections of image systems with and without spectroscopic redshifts and quantify the systematics using several diagnostics: image predictability, accuracy of model-predicted redshifts, enclosed mass, and magnification. We find that for models with >15 image systems, the image plane rms does not decrease significantly when more systems are added; however, the rms values quoted in the literature may be misleading asmore » to the ability of a model to predict new multiple images. The mass is well constrained near the Einstein radius in all cases, and systematic error drops to <2% for models using >10 image systems. Magnification errors are smallest along the straight portions of the critical curve, and the value of the magnification is systematically lower near curved portions. For >15 systems, the systematic error on magnification is ∼2%. We report no trend in magnification error with the fraction of spectroscopic image systems when selecting constraints at random; however, when using the same selection of constraints, increasing this fraction up to ∼0.5 will increase model accuracy. The results suggest that the selection of constraints, rather than quantity alone, determines the accuracy of the magnification. We note that spectroscopic follow-up of at least a few image systems is crucial because models without any spectroscopic redshifts are inaccurate across all of our diagnostics.« less
Hette Tronquart, Nicolas; Mazeas, Laurent; Reuilly-Manenti, Liana; Zahm, Amandine; Belliard, Jérôme
2012-07-30
Dorsal white muscle is the standard tissue analysed in fish trophic studies using stable isotope analyses. However, sampling white muscle often implies the sacrifice of fish. Thus, we examined whether the non-lethal sampling of fin tissue can substitute muscle sampling in food web studies. Analysing muscle and fin δ(15)N and δ(13)C values of 466 European freshwater fish (14 species) with an elemental analyser coupled with an isotope ratio mass spectrometer, we compared the isotope values of the two tissues. Correlations between fin and muscle isotope ratios were examined for all fish together and specifically for 12 species. We further proposed four methods of assessing muscle from fin isotope ratios and estimated the errors made using these muscle surrogates. Despite significant differences between isotope values of the two tissues, fin and muscle isotopic signals are strongly correlated. Muscle values, estimated with raw fin isotope ratios (1st method), induce an error of ca. 1‰ for both isotopes. In comparison, specific (2nd method) or general (3rd method) correlations provide meaningful corrections of fin isotope ratios (errors <0.6‰). On the other hand, relationships, established for Australian tropical fish, only give poor muscle estimates (errors >0.8‰). There is little chance that a global model can be created. However, the 2nd and 3rd methods of estimating muscle values from fin isotope ratios should provide an acceptable level of error for the studies of European freshwater food web. We thus recommend that future studies use fin tissue as a non-lethal surrogate for muscle. Copyright © 2012 John Wiley & Sons, Ltd.
A Dynamic Attitude Measurement System Based on LINS
Li, Hanzhou; Pan, Quan; Wang, Xiaoxu; Zhang, Juanni; Li, Jiang; Jiang, Xiangjun
2014-01-01
A dynamic attitude measurement system (DAMS) is developed based on a laser inertial navigation system (LINS). Three factors of the dynamic attitude measurement error using LINS are analyzed: dynamic error, time synchronization and phase lag. An optimal coning errors compensation algorithm is used to reduce coning errors, and two-axis wobbling verification experiments are presented in the paper. The tests indicate that the attitude accuracy is improved 2-fold by the algorithm. In order to decrease coning errors further, the attitude updating frequency is improved from 200 Hz to 2000 Hz. At the same time, a novel finite impulse response (FIR) filter with three notches is designed to filter the dither frequency of the ring laser gyro (RLG). The comparison tests suggest that the new filter is five times more effective than the old one. The paper indicates that phase-frequency characteristics of FIR filter and first-order holder of navigation computer constitute the main sources of phase lag in LINS. A formula to calculate the LINS attitude phase lag is introduced in the paper. The expressions of dynamic attitude errors induced by phase lag are derived. The paper proposes a novel synchronization mechanism that is able to simultaneously solve the problems of dynamic test synchronization and phase compensation. A single-axis turntable and a laser interferometer are applied to verify the synchronization mechanism. The experiments results show that the theoretically calculated values of phase lag and attitude error induced by phase lag can both match perfectly with testing data. The block diagram of DAMS and physical photos are presented in the paper. The final experiments demonstrate that the real-time attitude measurement accuracy of DAMS can reach up to 20″ (1σ) and the synchronization error is less than 0.2 ms on the condition of three axes wobbling for 10 min. PMID:25177802
A steep peripheral ring in irregular cornea topography, real or an instrument error?
Galindo-Ferreiro, Alicia; Galvez-Ruiz, Alberto; Schellini, Silvana A; Galindo-Alonso, Julio
2016-01-01
To demonstrate that the steep peripheral ring (red zone) on corneal topography after myopic laser in situ keratomileusis (LASIK) could possibly due to instrument error and not always to a real increase in corneal curvature. A spherical model for the corneal surface and modifying topography software was used to analyze the cause of an error due to instrument design. This study involved modification of the software of a commercially available topographer. A small modification of the topography image results in a red zone on the corneal topography color map. Corneal modeling indicates that the red zone could be an artifact due to an instrument-induced error. The steep curvature changes after LASIK, signified by the red zone, could be also an error due to the plotting algorithms of the corneal topographer, besides a steep curvature change.
Study on optical 3D angular deformations measurement
NASA Astrophysics Data System (ADS)
Gao, Yang; Wang, Xingshu; Huang, Zongsheng; Yang, Jinliang
2013-12-01
3D angular deformations will be inevitable when ships are sailing, due to the changes of the environmental temperature and external stresses. The measurement of 3D angular deformations is one of the most critical and difficult issues in navy and shipbuilding industry around the world. In this paper, we propose an optical method to measure 3D ship angular deformations and discuss the measurement errors in detail. Theoretical analysis shows that the measured errors of the pitching and yawing deformations are induced by the installation errors of the image aperture, and the measured error of the rolling deformation depends on the subpixel location algorithm in image processing. It indicates that the measured errors of the optical measurement proposed in this paper are at the magnitude of angular seconds, when the elaborated installation and precise image processing technology are both performed.
NASA Astrophysics Data System (ADS)
Debchoudhury, Shantanab; Earle, Gregory
2017-04-01
Retarding Potential Analyzers (RPA) have a rich flight heritage. Standard curve-fitting analysis techniques exist that can infer state variables in the ionospheric plasma environment from RPA data, but the estimation process is prone to errors arising from a number of sources. Previous work has focused on the effects of grid geometry on uncertainties in estimation; however, no prior study has quantified the estimation errors due to additive noise. In this study, we characterize the errors in estimation of thermal plasma parameters by adding noise to the simulated data derived from the existing ionospheric models. We concentrate on low-altitude, mid-inclination orbits since a number of nano-satellite missions are focused on this region of the ionosphere. The errors are quantified and cross-correlated for varying geomagnetic conditions.
Method for Real-Time Model Based Structural Anomaly Detection
NASA Technical Reports Server (NTRS)
Urnes, James M., Sr. (Inventor); Smith, Timothy A. (Inventor); Reichenbach, Eric Y. (Inventor)
2015-01-01
A system and methods for real-time model based vehicle structural anomaly detection are disclosed. A real-time measurement corresponding to a location on a vehicle structure during an operation of the vehicle is received, and the real-time measurement is compared to expected operation data for the location to provide a modeling error signal. A statistical significance of the modeling error signal to provide an error significance is calculated, and a persistence of the error significance is determined. A structural anomaly is indicated, if the persistence exceeds a persistence threshold value.
Learning-Induced Plasticity in Medial Prefrontal Cortex Predicts Preference Malleability
Garvert, Mona M.; Moutoussis, Michael; Kurth-Nelson, Zeb; Behrens, Timothy E.J.; Dolan, Raymond J.
2015-01-01
Summary Learning induces plasticity in neuronal networks. As neuronal populations contribute to multiple representations, we reasoned plasticity in one representation might influence others. We used human fMRI repetition suppression to show that plasticity induced by learning another individual’s values impacts upon a value representation for oneself in medial prefrontal cortex (mPFC), a plasticity also evident behaviorally in a preference shift. We show this plasticity is driven by a striatal “prediction error,” signaling the discrepancy between the other’s choice and a subject’s own preferences. Thus, our data highlight that mPFC encodes agent-independent representations of subjective value, such that prediction errors simultaneously update multiple agents’ value representations. As the resulting change in representational similarity predicts interindividual differences in the malleability of subjective preferences, our findings shed mechanistic light on complex human processes such as the powerful influence of social interaction on beliefs and preferences. PMID:25611512
Development and Characterization of a Low-Pressure Calibration System for Hypersonic Wind Tunnels
NASA Technical Reports Server (NTRS)
Green, Del L.; Everhart, Joel L.; Rhode, Matthew N.
2004-01-01
Minimization of uncertainty is essential for accurate ESP measurements at very low free-stream static pressures found in hypersonic wind tunnels. Statistical characterization of environmental error sources requires a well defined and controlled calibration method. A calibration system has been constructed and environmental control software developed to control experimentation to eliminate human induced error sources. The initial stability study of the calibration system shows a high degree of measurement accuracy and precision in temperature and pressure control. Control manometer drift and reference pressure instabilities induce uncertainty into the repeatability of voltage responses measured from the PSI System 8400 between calibrations. Methods of improving repeatability are possible through software programming and further experimentation.
Is there an "abortion trauma syndrome"? Critiquing the evidence.
Robinson, Gail Erlick; Stotland, Nada L; Russo, Nancy Felipe; Lang, Joan A; Occhiogrosso, Mallay
2009-01-01
The objective of this review is to identify and illustrate methodological issues in studies used to support claims that induced abortion results in an "abortion trauma syndrome" or a psychiatric disorder. After identifying key methodological issues to consider when evaluating such research, we illustrate these issues by critically examining recent empirical studies that are widely cited in legislative and judicial testimony in support of the existence of adverse psychiatric sequelae of induced abortion. Recent studies that have been used to assert a causal connection between abortion and subsequent mental disorders are marked by methodological problems that include, but not limited to: poor sample and comparison group selection; inadequate conceptualization and control of relevant variables; poor quality and lack of clinical significance of outcome measures; inappropriateness of statistical analyses; and errors of interpretation, including misattribution of causal effects. By way of contrast, we review some recent major studies that avoid these methodological errors. The most consistent predictor of mental disorders after abortion remains preexisting disorders, which, in turn, are strongly associated with exposure to sexual abuse and intimate violence. Educating researchers, clinicians, and policymakers how to appropriately assess the methodological quality of research about abortion outcomes is crucial. Further, methodologically sound research is needed to evaluate not only psychological outcomes of abortion, but also the impact of existing legislation and the effects of social attitudes and behaviors on women who have abortions.
Reduction of the Misinformation Effect by Arousal Induced after Learning
ERIC Educational Resources Information Center
English, Shaun M.; Nielson, Kristy A.
2010-01-01
Misinformation introduced after events have already occurred causes errors in later retrieval. Based on literature showing that arousal induced after learning enhances delayed retrieval, we investigated whether post-learning arousal can reduce the misinformation effect. 251 participants viewed four short film clips, each followed by a retention…
Foley, Mary Ann; Foy, Jeffrey; Schlemmer, Emily; Belser-Ehrlich, Janna
2010-11-01
Imagery encoding effects on source-monitoring errors were explored using the Deese-Roediger-McDermott paradigm in two experiments. While viewing thematically related lists embedded in mixed picture/word presentations, participants were asked to generate images of objects or words (Experiment 1) or to simply name the items (Experiment 2). An encoding task intended to induce spontaneous images served as a control for the explicit imagery instruction conditions (Experiment 1). On the picture/word source-monitoring tests, participants were much more likely to report "seeing" a picture of an item presented as a word than the converse particularly when images were induced spontaneously. However, this picture misattribution error was reversed after generating images of words (Experiment 1) and was eliminated after simply labelling the items (Experiment 2). Thus source misattributions were sensitive to the processes giving rise to imagery experiences (spontaneous vs deliberate), the kinds of images generated (object vs word images), and the ways in which materials were presented (as pictures vs words).
An adaptive optics system for solid-state laser systems used in inertial confinement fusion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salmon, J.T.; Bliss, E.S.; Byrd, J.L.
1995-09-17
Using adaptive optics the authors have obtained nearly diffraction-limited 5 kJ, 3 nsec output pulses at 1.053 {micro}m from the Beamlet demonstration system for the National Ignition Facility (NIF). The peak Strehl ratio was improved from 0.009 to 0.50, as estimated from measured wavefront errors. They have also measured the relaxation of the thermally induced aberrations in the main beam line over a period of 4.5 hours. Peak-to-valley aberrations range from 6.8 waves at 1.053 {micro}m within 30 minutes after a full system shot to 3.9 waves after 4.5 hours. The adaptive optics system must have enough range to correctmore » accumulated thermal aberrations from several shots in addition to the immediate shot-induced error. Accumulated wavefront errors in the beam line will affect both the design of the adaptive optics system for NIF and the performance of that system.« less
Increased impulsivity in response to food cues after sleep loss in healthy young men
Cedernaes, Jonathan; Brandell, Jon; Ros, Olof; Broman, Jan-Erik; Hogenkamp, Pleunie S; Schiöth, Helgi B; Benedict, Christian
2014-01-01
Objective To investigate whether acute total sleep deprivation (TSD) leads to decreased cognitive control when food cues are presented during a task requiring active attention, by assessing the ability to cognitively inhibit prepotent responses. Methods Fourteen males participated in the study on two separate occasions in a randomized, crossover within-subject design: one night of TSD versus normal sleep (8.5 hours). Following each nighttime intervention, hunger ratings and morning fasting plasma glucose concentrations were assessed before performing a go/no-go task. Results Following TSD, participants made significantly more commission errors when they were presented “no-go” food words in the go/no-go task, as compared with their performance following sleep (+56%; P<0.05). In contrast, response time and omission errors to “go” non-food words did not differ between the conditions. Self-reported hunger after TSD was increased without changes in fasting plasma glucose. The increase in hunger did not correlate with the TSD-induced commission errors. Conclusions Our results suggest that TSD impairs cognitive control also in response to food stimuli in healthy young men. Whether such loss of inhibition or impulsiveness is food cue-specific as seen in obesity—thus providing a mechanism through which sleep disturbances may promote obesity development—warrants further investigation. PMID:24839251
Proton irradiation effects on advanced digital and microwave III-V components
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hash, G.L.; Schwank, J.R.; Shaneyfelt, M.R.
1994-09-01
A wide range of advanced III-V components suitable for use in high-speed satellite communication systems were evaluated for displacement damage and single-event effects in high-energy, high-fluence proton environments. Transistors and integrated circuits (both digital and MMIC) were irradiated with protons at energies from 41 to 197 MeV and at fluences from 10{sup 10} to 2 {times} 10{sup 14} protons/cm{sup 2}. Large soft-error rates were measured for digital GaAs MESFET (3 {times} 10{sup {minus}5} errors/bit-day) and heterojunction bipolar circuits (10{sup {minus}5} errors/bit-day). No transient signals were detected from MMIC circuits. The largest degradation in transistor response caused by displacement damage wasmore » observed for 1.0-{mu}m depletion- and enhancement-mode MESFET transistors. Shorter gate length MESFET transistors and HEMT transistors exhibited less displacement-induced damage. These results show that memory-intensive GaAs digital circuits may result in significant system degradation due to single-event upset in natural and man-made space environments. However, displacement damage effects should not be a limiting factor for fluence levels up to 10{sup 14} protons/cm{sup 2} [equivalent to total doses in excess of 10 Mrad(GaAs)].« less
Proton irradiation effects on advanced digital and microwave III-V components
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hash, G.L.; Schwank, J.R.; Shaneyfelt, M.R.
1994-12-01
A wide range of advanced III-V components suitable for use in high-speed satellite communication systems were evaluated for displacement damage and single-event effects in high-energy, high-fluence proton environments. Transistors and integrated circuits (both digital and MMIC) were irradiated with protons at energies from 41 to 197 MeV and at fluences from 10[sup 10] to 2 [times] 10[sup 14] protons/cm[sup 2]. Large soft-error rates were measured for digital GaAs MESFET (3 [times] 10[sup [minus]5] errors/bit-day) and heterojunction bipolar circuits (10[sup [minus]5] errors/bit-day). No transient signals were detected from MMIC circuits. The largest degradation in transistor response caused by displacement damage wasmore » observed for 1.0-[mu]m depletion- and enhancement-mode MESFET transistors. Shorter gate length MESFET transistors and HEMT transistors exhibited less displacement-induced damage. These results show that memory-intensive GaAs digital circuits may result in significant system degradation due to single-event upset in natural and man-made space environments. However, displacement damage effects should not be a limiting factor for fluence levels up to 10[sup 14] protons/cm[sup 2] [equivalent to total doses in excess of 10 Mrad (GaAs)].« less
Design Techniques for Power-Aware Combinational Logic SER Mitigation
NASA Astrophysics Data System (ADS)
Mahatme, Nihaar N.
The history of modern semiconductor devices and circuits suggests that technologists have been able to maintain scaling at the rate predicted by Moore's Law [Moor-65]. With improved performance, speed and lower area, technology scaling has also exacerbated reliability issues such as soft errors. Soft errors are transient errors that occur in microelectronic circuits due to ionizing radiation particle strikes on reverse biased semiconductor junctions. These radiation induced errors at the terrestrial-level are caused due to radiation particle strikes by (1) alpha particles emitted as decay products of packing material (2) cosmic rays that produce energetic protons and neutrons, and (3) thermal neutrons [Dodd-03], [Srou-88] and more recently muons and electrons [Ma-79] [Nara-08] [Siew-10] [King-10]. In the space environment radiation induced errors are a much bigger threat and are mainly caused by cosmic heavy-ions, protons etc. The effects of radiation exposure on circuits and measures to protect against them have been studied extensively for the past 40 years, especially for parts operating in space. Radiation particle strikes can affect memory as well as combinational logic. Typically when these particles strike semiconductor junctions of transistors that are part of feedback structures such as SRAM memory cells or flip-flops, it can lead to an inversion of the cell content. Such a failure is formally called a bit-flip or single-event upset (SEU). When such particles strike sensitive junctions part of combinational logic gates they produce transient voltage spikes or glitches called single-event transients (SETs) that could be latched by receiving flip-flops. As the circuits are clocked faster, there are more number of clocking edges which increases the likelihood of latching these transients. In older technology generations the probability of errors in flip-flops due to SETs being latched was much lower compared to direct strikes on flip-flops or SRAMs leading to SEUs. This was mainly because the operating frequencies were much lower for older technology generations. The Intel Pentium II for example was fabricated using 0.35 microm technology and operated between 200-330 MHz. With technology scaling however, operating frequencies have increased tremendously and the contribution of soft errors due to latched SETs from combinational logic could account for a significant proportion of the chip-level soft error rate [Sief-12][Maha-11][Shiv02] [Bu97]. Therefore there is a need to systematically characterize the problem of combinational logic single-event effects (SEE) and understand the various factors that affect the combinational logic single-event error rate. Just as scaling has led to soft errors emerging as a reliability-limiting failure mode for modern digital ICs, the problem of increasing power consumption has arguably been a bigger bane of scaling. While Moore's Law loftily states the blessing of technology scaling to be smaller and faster transistor it fails to highlight that the power density increases exponentially with every technology generation. The power density problem was partially solved in the 1970's and 1980's by moving from bipolar and GaAs technologies to full-scale silicon CMOS technologies. Following this however, technology miniaturization that enabled high-speed, multicore and parallel computing has steadily increased the power density and the power consumption problem. Today minimizing the power consumption is as much critical for power hungry server farms as it for portable devices, all pervasive sensor networks and future eco-bio-sensors. Low-power consumption is now regularly part of design philosophies for various digital products with diverse applications from computing to communication to healthcare. Thus designers in today's world are left grappling with both a "power wall" as well as a "reliability wall". Unfortunately, when it comes to improving reliability through soft error mitigation, most approaches are invariably straddled with overheads in terms of area or speed and more importantly power. Thus, the cost of protecting combinational logic through the use of power hungry mitigation approaches can disrupt the power budget significantly. Therefore there is a strong need to develop techniques that can provide both power minimization as well as combinational logic soft error mitigation. This dissertation, advances hitherto untapped opportunities to jointly reduce power consumption and deliver soft error resilient designs. Circuit as well as architectural approaches are employed to achieve this objective and the advantages of cross-layer optimization for power and soft error reliability are emphasized.
Headaches associated with refractive errors: myth or reality?
Gil-Gouveia, R; Martins, I P
2002-04-01
Headache and refractive errors are very common conditions in the general population, and those with headache often attribute their pain to a visual problem. The International Headache Society (IHS) criteria for the classification of headache includes an entity of headache associated with refractive errors (HARE), but indicates that its importance is widely overestimated. To compare overall headache frequency and HARE frequency in healthy subjects with uncorrected or miscorrected refractive errors and a control group. We interviewed 105 individuals with uncorrected refractive errors and a control group of 71 subjects (with properly corrected or without refractive errors) regarding their headache history. We compared the occurrence of headache and its diagnosis in both groups and assessed its relation to their habits of visual effort and type of refractive errors. Headache frequency was similar in both subjects and controls. Headache associated with refractive errors was the only headache type significantly more common in subjects with refractive errors than in controls (6.7% versus 0%). It was associated with hyperopia and was unrelated to visual effort or to the severity of visual error. With adequate correction, 72.5% of the subjects with headache and refractive error reported improvement in their headaches, and 38% had complete remission of headache. Regardless of the type of headache present, headache frequency was significantly reduced in these subjects (t = 2.34, P =.02). Headache associated with refractive errors was rarely identified in individuals with refractive errors. In those with chronic headache, proper correction of refractive errors significantly improved headache complaints and did so primarily by decreasing the frequency of headache episodes.
Sleep, mental health status, and medical errors among hospital nurses in Japan.
Arimura, Mayumi; Imai, Makoto; Okawa, Masako; Fujimura, Toshimasa; Yamada, Naoto
2010-01-01
Medical error involving nurses is a critical issue since nurses' actions will have a direct and often significant effect on the prognosis of their patients. To investigate the significance of nurse health in Japan and its potential impact on patient services, a questionnaire-based survey amongst nurses working in hospitals was conducted, with the specific purpose of examining the relationship between shift work, mental health and self-reported medical errors. Multivariate analysis revealed significant associations between the shift work system, General Health Questionnaire (GHQ) scores and nurse errors: the odds ratios for shift system and GHQ were 2.1 and 1.1, respectively. It was confirmed that both sleep and mental health status among hospital nurses were relatively poor, and that shift work and poor mental health were significant factors contributing to medical errors.
Justification of Estimates for Fiscal Year 1983 Submitted to Congress.
1982-02-01
hierarchies to aid software production; completion of the components of an adaptive suspension vehicle including a storage energy unit, hydraulics, laser...and corrosion (long storage times), and radiation-induced breakdown. Solid- lubricated main engine bearings for cruise missile engines would offer...environments will cause "soft error" (computational and memory storage errors) in advanced microelectronic circuits. Research on high-speed, low-power
Comment on "Infants' perseverative search errors are induced by pragmatic misinterpretation".
Spencer, John P; Dineva, Evelina; Smith, Linda B
2009-09-25
Topál et al. (Reports, 26 September 2008, p. 1831) proposed that infants' perseverative search errors can be explained by ostensive cues from the experimenter. We use the dynamic field theory to test the proposal that infants encode locations more weakly when social cues are present. Quantitative simulations show that this account explains infants' performance without recourse to the theory of natural pedagogy.
Exercise-Induced Hypoalgesia After Isometric Wall Squat Exercise: A Test-Retest Reliabilty Study.
Vaegter, Henrik Bjarke; Lyng, Kristian Damgaard; Yttereng, Fredrik Wannebo; Christensen, Mads Holst; Sørensen, Mathias Brandhøj; Graven-Nielsen, Thomas
2018-05-19
Isometric exercises decrease pressure pain sensitivity in exercising and nonexercising muscles known as exercise-induced hypoalgesia (EIH). No studies have assessed the test-retest reliability of EIH after isometric exercise. This study investigated the EIH on pressure pain thresholds (PPTs) after an isometric wall squat exercise. The relative and absolute test-retest reliability of the PPT as a test stimulus and the EIH response in exercising and nonexercising muscles were calculated. In two identical sessions, PPTs of the thigh and shoulder were assessed before and after three minutes of quiet rest and three minutes of wall squat exercise, respectively, in 35 healthy subjects. The relative test-retest reliability of PPT and EIH was determined using analysis of variance models, Person's r, and intraclass correlations (ICCs). The absolute test-retest reliability of EIH was determined based on PPT standard error of measurements and Cohen's kappa for agreement between sessions. Squat increased PPTs of exercising and nonexercising muscles by 16.8% ± 16.9% and 6.7% ± 12.9%, respectively (P < 0.001), with no significant differences between sessions. PPTs within and between sessions showed moderately strong correlations (r ≥ 0.74) and excellent (ICC ≥ 0.84) within-session (rest) and between-session test-retest reliability. EIH responses of exercising and nonexercising muscles showed no systematic errors between sessions; however, the relative test-retest reliability was low (ICCs = 0.03-0.43), and agreement in EIH responders and nonresponders between sessions was not significant (κ < 0.13, P > 0.43). A wall squat exercise increased PPTs compared with quiet rest; however, the relative and absolute reliability of the EIH response was poor. Future research is warranted to investigate the reliability of EIH in clinical pain populations.
NASA Astrophysics Data System (ADS)
Xie, L.; Pietrafesa, L. J.; Wu, K.
2003-02-01
A three-dimensional wave-current coupled modeling system is used to examine the influence of waves on coastal currents and sea level. This coupled modeling system consists of the wave model-WAM (Cycle 4) and the Princeton Ocean Model (POM). The results from this study show that it is important to incorporate surface wave effects into coastal storm surge and circulation models. Specifically, we find that (1) storm surge models without coupled surface waves generally under estimate not only the peak surge but also the coastal water level drop which can also cause substantial impact on the coastal environment, (2) introducing wave-induced surface stress effect into storm surge models can significantly improve storm surge prediction, (3) incorporating wave-induced bottom stress into the coupled wave-current model further improves storm surge prediction, and (4) calibration of the wave module according to minimum error in significant wave height does not necessarily result in an optimum wave module in a wave-current coupled system for current and storm surge prediction.
Evidence for Universality in the Initial Planetesimal Mass Function
NASA Astrophysics Data System (ADS)
Simon, Jacob B.; Armitage, Philip J.; Youdin, Andrew N.; Li, Rixin
2017-10-01
Planetesimals may form from the gravitational collapse of dense particle clumps initiated by the streaming instability. We use simulations of aerodynamically coupled gas-particle mixtures to investigate whether the properties of planetesimals formed in this way depend upon the sizes of the particles that participate in the instability. Based on three high-resolution simulations that span a range of dimensionless stopping times 6× {10}-3≤slant τ ≤slant 2, no statistically significant differences in the initial planetesimal mass function are found. The mass functions are fit by a power law, {dN}/{{dM}}p\\propto {M}p-p, with p = 1.5-1.7 and errors of {{Δ }}p≈ 0.1. Comparing the particle density fields prior to collapse, we find that the high-wavenumber power spectra are similarly indistinguishable, though the large-scale geometry of structures induced via the streaming instability is significantly different between all three cases. We interpret the results as evidence for a near-universal slope to the mass function, arising from the small-scale structure of streaming-induced turbulence.
Astigmatism in Monkeys with Experimentally Induced Myopia or Hyperopia
KEE, CHEA-SU; HUNG, LI-FANG; QIAO-GRIDER, YING; RAMAMIRTHAM, RAMKUMAR; SMITH, EARL L.
2006-01-01
Purpose Astigmatism is the most common ametropia found in humans and is often associated with large spherical ametropias. However, little is known about the etiology of astigmatism or the reason(s) for the association between spherical and astigmatic refractive errors. This study examines the frequency and characteristics of astigmatism in infant monkeys that developed axial ametropias as a result of altered early visual experience. Methods Data were obtained from 112 rhesus monkeys that experienced a variety of lens-rearing regimens that were intended to alter the normal course of emmetropization. These visual manipulations included form deprivation (n = 13); optically imposed defocus (n = 48); and continuous ambient lighting with (n = 6) or without optically imposed defocus (n = 6). In addition, data from 19 control monkeys and 39 infants reared with an optically imposed astigmatism were used for comparison purposes. The lens-rearing period started at approximately 3 weeks of age and ended by 4 to 5 months of age. Refractive development for all monkeys was assessed periodically throughout the treatment and subsequent recovery periods by retinoscopy, keratometry, and A-scan ultrasonography. Results In contrast to control monkeys, the monkeys that had experimentally induced axial ametropias frequently developed significant amounts of astigmatism (mean refractive astigmatism = 0.37 ± 0.33 D [control] vs. 1.24 ± 0.81 D [treated]; two-sample t-test, p < 0.0001), especially when their eyes exhibited relative hyperopic shifts in refractive error. The astigmatism was corneal in origin (Pearson’s r; p < 0.001 for total astigmatism and the JO and J45 components), and the axes of the astigmatism were typically oblique and bilaterally mirror symmetric. Interestingly, the astigmatism was not permanent; the majority of the monkeys exhibited substantial reductions in the amount of astigmatism at or near the end of the lens-rearing procedures. Conclusions In infant monkeys, visual conditions that alter axial growth can also alter corneal shape. Similarities between the astigmatic errors in our monkeys and some astigmatic errors in humans suggest that vision-dependent changes in eye growth may contribute to astigmatism in humans. PMID:15829845
Corenman, Donald S; Strauch, Eric L; Dornan, Grant J; Otterstrom, Eric; Zalepa King, Lisa
2017-09-01
Advancements in surgical navigation technology coupled with 3-dimensional (3D) radiographic data have significantly enhanced the accuracy and efficiency of spinal fusion implant placement. Increased usage of such technology has led to rising concerns regarding maintenance of the sterile field, as makeshift drape systems are fraught with breaches thus presenting increased risk of surgical site infections (SSIs). A clinical need exists for a sterile draping solution with these techniques. Our objective was to quantify expected accuracy error associated with 2MM and 4MM thickness Sterile-Z Patient Drape ® using Medtronic O-Arm ® Surgical Imaging with StealthStation ® S7 ® Navigation System. Camera distance to reference frame was investigated for contribution to accuracy error. A testing jig was placed on the radiolucent table and the Medtronic passive reference frame was attached to jig. The StealthStation ® S7 ® navigation camera was placed at various distances from testing jig and the geometry error of reference frame was captured for three different drape configurations: no drape, 2MM drape and 4MM drape. The O-Arm ® gantry location and StealthStation ® S7 ® camera position was maintained and seven 3D acquisitions for each of drape configurations were measured. Data was analyzed by a two-factor analysis of variance (ANOVA) and Bonferroni comparisons were used to assess the independent effects of camera angle and drape on accuracy error. Median (and maximum) measurement accuracy error was higher for the 2MM than for the 4MM drape for each camera distance. The most extreme error observed (4.6 mm) occurred when using the 2MM and the 'far' camera distance. The 4MM drape was found to induce an accuracy error of 0.11 mm (95% confidence interval, 0.06-0.15; P<0.001) relative to the no drape testing, regardless of camera distance. Medium camera distance produced lower accuracy error than either the close (additional 0.08 mm error; 95% CI, 0-0.15; P=0.035) or far (additional 0.21mm error; 95% CI, 0.13-0.28; P<0.001) camera distances, regardless of whether a drape was used. In comparison to the 'no drape' condition, the accuracy error of 0.11 mm when using a 4MM film drape is minimal and clinically insignificant.
Ketamine-xylazine anesthesia causes hyperopic refractive shift in mice
Tkatchenko, Tatiana V.; Tkatchenko, Andrei V.
2010-01-01
Mice have increasingly been used as a model for studies of myopia. The key to successful use of mice for myopia research is the ability to obtain accurate measurements of refractive status of their eyes. In order to obtain accurate measurements of refractive errors in mice, the refraction needs to be performed along the optical axis of the eye. This represents a particular challenge, because mice are very difficult to immobilize. Recently, ketamine-xylazine anesthesia has been used to immobilize mice before measuring refractive errors, in combination with tropicamide ophthalmic solution to induce mydriasis. Although these drugs have increasingly been used while refracting mice, their effects on the refractive state of the mouse eye have not yet been investigated. Therefore, we have analyzed the effects of tropicamide eye drops and ketamine-xylazine anesthesia on refraction in P40 C57BL/6J mice. We have also explored two alternative methods to immobilize mice, i.e. the use of a restraining platform and pentobarbital anesthesia. We found that tropicamide caused a very small, but statistically significant, hyperopic shift in refraction. Pentobarbital did not have any substantial effect on refractive status, whereas ketamine-xylazine caused a large and highly significant hyperopic shift in refraction. We also found that the use of a restraining platform represents good alternative for immobilization of mice prior to refraction. Thus, our data suggest that ketamine-xylazine anesthesia should be avoided in studies of refractive development in mice and underscore the importance of providing appropriate experimental conditions when measuring refractive errors in mice. PMID:20813132
Ing, Alex; Schwarzbauer, Christian
2014-01-01
Functional connectivity has become an increasingly important area of research in recent years. At a typical spatial resolution, approximately 300 million connections link each voxel in the brain with every other. This pattern of connectivity is known as the functional connectome. Connectivity is often compared between experimental groups and conditions. Standard methods used to control the type 1 error rate are likely to be insensitive when comparisons are carried out across the whole connectome, due to the huge number of statistical tests involved. To address this problem, two new cluster based methods--the cluster size statistic (CSS) and cluster mass statistic (CMS)--are introduced to control the family wise error rate across all connectivity values. These methods operate within a statistical framework similar to the cluster based methods used in conventional task based fMRI. Both methods are data driven, permutation based and require minimal statistical assumptions. Here, the performance of each procedure is evaluated in a receiver operator characteristic (ROC) analysis, utilising a simulated dataset. The relative sensitivity of each method is also tested on real data: BOLD (blood oxygen level dependent) fMRI scans were carried out on twelve subjects under normal conditions and during the hypercapnic state (induced through the inhalation of 6% CO2 in 21% O2 and 73%N2). Both CSS and CMS detected significant changes in connectivity between normal and hypercapnic states. A family wise error correction carried out at the individual connection level exhibited no significant changes in connectivity.
Effect of contrast on human speed perception
NASA Technical Reports Server (NTRS)
Stone, Leland S.; Thompson, Peter
1992-01-01
This study is part of an ongoing collaborative research effort between the Life Science and Human Factors Divisions at NASA ARC to measure the accuracy of human motion perception in order to predict potential errors in human perception/performance and to facilitate the design of display systems that minimize the effects of such deficits. The study describes how contrast manipulations can produce significant errors in human speed perception. Specifically, when two simultaneously presented parallel gratings are moving at the same speed within stationary windows, the lower-contrast grating appears to move more slowly. This contrast-induced misperception of relative speed is evident across a wide range of contrasts (2.5-50 percent) and does not appear to saturate (e.g., a 50 percent contrast grating appears slower than a 70 percent contrast grating moving at the same speed). The misperception is large: a 70 percent contrast grating must, on average, be slowed by 35 percent to match a 10 percent contrast grating moving at 2 deg/sec (N = 6). Furthermore, it is largely independent of the absolute contrast level and is a quasilinear function of log contrast ratio. A preliminary parametric study shows that, although spatial frequency has little effect, the relative orientation of the two gratings is important. Finally, the effect depends on the temporal presentation of the stimuli: the effects of contrast on perceived speed appears lessened when the stimuli to be matched are presented sequentially. These data constrain both physiological models of visual cortex and models of human performance. We conclude that viewing conditions that effect contrast, such as fog, may cause significant errors in speed judgments.
Ing, Alex; Schwarzbauer, Christian
2014-01-01
Functional connectivity has become an increasingly important area of research in recent years. At a typical spatial resolution, approximately 300 million connections link each voxel in the brain with every other. This pattern of connectivity is known as the functional connectome. Connectivity is often compared between experimental groups and conditions. Standard methods used to control the type 1 error rate are likely to be insensitive when comparisons are carried out across the whole connectome, due to the huge number of statistical tests involved. To address this problem, two new cluster based methods – the cluster size statistic (CSS) and cluster mass statistic (CMS) – are introduced to control the family wise error rate across all connectivity values. These methods operate within a statistical framework similar to the cluster based methods used in conventional task based fMRI. Both methods are data driven, permutation based and require minimal statistical assumptions. Here, the performance of each procedure is evaluated in a receiver operator characteristic (ROC) analysis, utilising a simulated dataset. The relative sensitivity of each method is also tested on real data: BOLD (blood oxygen level dependent) fMRI scans were carried out on twelve subjects under normal conditions and during the hypercapnic state (induced through the inhalation of 6% CO2 in 21% O2 and 73%N2). Both CSS and CMS detected significant changes in connectivity between normal and hypercapnic states. A family wise error correction carried out at the individual connection level exhibited no significant changes in connectivity. PMID:24906136
Defining the Relationship Between Human Error Classes and Technology Intervention Strategies
NASA Technical Reports Server (NTRS)
Wiegmann, Douglas A.; Rantanen, Esa; Crisp, Vicki K. (Technical Monitor)
2002-01-01
One of the main factors in all aviation accidents is human error. The NASA Aviation Safety Program (AvSP), therefore, has identified several human-factors safety technologies to address this issue. Some technologies directly address human error either by attempting to reduce the occurrence of errors or by mitigating the negative consequences of errors. However, new technologies and system changes may also introduce new error opportunities or even induce different types of errors. Consequently, a thorough understanding of the relationship between error classes and technology "fixes" is crucial for the evaluation of intervention strategies outlined in the AvSP, so that resources can be effectively directed to maximize the benefit to flight safety. The purpose of the present project, therefore, was to examine the repositories of human factors data to identify the possible relationship between different error class and technology intervention strategies. The first phase of the project, which is summarized here, involved the development of prototype data structures or matrices that map errors onto "fixes" (and vice versa), with the hope of facilitating the development of standards for evaluating safety products. Possible follow-on phases of this project are also discussed. These additional efforts include a thorough and detailed review of the literature to fill in the data matrix and the construction of a complete database and standards checklists.
Is adult gait less susceptible than paediatric gait to hip joint centre regression equation error?
Kiernan, D; Hosking, J; O'Brien, T
2016-03-01
Hip joint centre (HJC) regression equation error during paediatric gait has recently been shown to have clinical significance. In relation to adult gait, it has been inferred that comparable errors with children in absolute HJC position may in fact result in less significant kinematic and kinetic error. This study investigated the clinical agreement of three commonly used regression equation sets (Bell et al., Davis et al. and Orthotrak) for adult subjects against the equations of Harrington et al. The relationship between HJC position error and subject size was also investigated for the Davis et al. set. Full 3-dimensional gait analysis was performed on 12 healthy adult subjects with data for each set compared to Harrington et al. The Gait Profile Score, Gait Variable Score and GDI-kinetic were used to assess clinical significance while differences in HJC position between the Davis and Harrington sets were compared to leg length and subject height using regression analysis. A number of statistically significant differences were present in absolute HJC position. However, all sets fell below the clinically significant thresholds (GPS <1.6°, GDI-Kinetic <3.6 points). Linear regression revealed a statistically significant relationship for both increasing leg length and increasing subject height with decreasing error in anterior/posterior and superior/inferior directions. Results confirm a negligible clinical error for adult subjects suggesting that any of the examined sets could be used interchangeably. Decreasing error with both increasing leg length and increasing subject height suggests that the Davis set should be used cautiously on smaller subjects. Copyright © 2016 Elsevier B.V. All rights reserved.
Dynamic dielectrophoresis model of multi-phase ionic fluids.
Yan, Ying; Luo, Jing; Guo, Dan; Wen, Shizhu
2015-01-01
Ionic-based dielectrophoretic microchips have attracted significant attention due to their wide-ranging applications in electro kinetic and biological experiments. In this work, a numerical method is used to simulate the dynamic behaviors of ionic droplets in a microchannel under the effect of dielectrophoresis. When a discrete liquid dielectric is encompassed within a continuous fluid dielectric placed in an electric field, an electric force is produced due to the dielectrophoresis effect. If either or both of the fluids are ionic liquids, the magnitude and even the direction of the force will be changed because the net ionic charge induced by an electric field can affect the polarization degree of the dielectrics. However, using a dielectrophoresis model, assuming ideal dielectrics, results in significant errors. To avoid the inaccuracy caused by the model, this work incorporates the electrode kinetic equation and defines a relationship between the polarization charge and the net ionic charge. According to the simulation conditions presented herein, the electric force obtained in this work has an error exceeding 70% of the actual value if the false effect of net ionic charge is not accounted for, which would result in significant issues in the design and optimization of experimental parameters. Therefore, there is a clear motivation for developing a model adapted to ionic liquids to provide precise control for the dielectrophoresis of multi-phase ionic liquids.
Porous plug for reducing orifice induced pressure error in airfoils
NASA Technical Reports Server (NTRS)
Plentovich, Elizabeth B. (Inventor); Gloss, Blair B. (Inventor); Eves, John W. (Inventor); Stack, John P. (Inventor)
1988-01-01
A porous plug is provided for the reduction or elimination of positive error caused by the orifice during static pressure measurements of airfoils. The porous plug is press fitted into the orifice, thereby preventing the error caused either by fluid flow turning into the exposed orifice or by the fluid flow stagnating at the downstream edge of the orifice. In addition, the porous plug is made flush with the outer surface of the airfoil, by filing and polishing, to provide a smooth surface which alleviates the error caused by imperfections in the orifice. The porous plug is preferably made of sintered metal, which allows air to pass through the pores, so that the static pressure measurements can be made by remote transducers.
Error Estimation and Uncertainty Propagation in Computational Fluid Mechanics
NASA Technical Reports Server (NTRS)
Zhu, J. Z.; He, Guowei; Bushnell, Dennis M. (Technical Monitor)
2002-01-01
Numerical simulation has now become an integral part of engineering design process. Critical design decisions are routinely made based on the simulation results and conclusions. Verification and validation of the reliability of the numerical simulation is therefore vitally important in the engineering design processes. We propose to develop theories and methodologies that can automatically provide quantitative information about the reliability of the numerical simulation by estimating numerical approximation error, computational model induced errors and the uncertainties contained in the mathematical models so that the reliability of the numerical simulation can be verified and validated. We also propose to develop and implement methodologies and techniques that can control the error and uncertainty during the numerical simulation so that the reliability of the numerical simulation can be improved.
Williams, Camille K; Grierson, Lawrence E M; Carnahan, Heather
2011-08-01
A link between affect and action has been supported by the discovery that threat information is prioritized through an action-centred pathway--the dorsal visual stream. Magnocellular afferents, which originate from the retina and project to dorsal stream structures, are suppressed by exposure to diffuse red light, which diminishes humans' perception of threat-based images. In order to explore the role of colour in the relationship between affect and action, participants donned different pairs of coloured glasses (red, yellow, green, blue and clear) and completed Positive and Negative Affect Scale questionnaires as well as a series of target-directed aiming movements. Analyses of affect scores revealed a significant main effect for affect valence and a significant interaction between colour and valence: perceived positive affect was significantly smaller for the red condition. Kinematic analyses of variable error in the primary movement direction and Pearson correlation analyses between the displacements travelled prior to and following peak velocity indicated reduced accuracy and application of online control processes while wearing red glasses. Variable error of aiming was also positively and significantly correlated with negative affect scores under the red condition. These results suggest that only red light modulates the affect-action link by suppressing magnocellular activity, which disrupts visual processing for movement control. Furthermore, previous research examining the effect of the colour red on psychomotor tasks and perceptual acceleration of threat-based imagery suggest that stimulus-driven motor performance tasks requiring online control may be particularly susceptible to this effect.
Fatigue in Younger and Older Drivers: Effectiveness of an Alertness-Maintaining Task.
Song, Woojin; Woon, Fu L; Doong, Alice; Persad, Carol; Tijerina, Louis; Pandit, Pooja; Cline, Carol; Giordani, Bruno
2017-09-01
The aim of this study was to examine the effects of an alertness-maintaining task (AMT) in older, fatigued drivers. Fatigue during driving increases crash risk, and previous research suggests that alertness and driving in younger adults may be improved using a secondary AMT during boring, fatigue-eliciting drives. However, the potential impact of an AMT on driving has not been investigated in older drivers whose ability to complete dual tasks has been shown to decline and therefore may be negatively affected with an AMT in driving. Younger ( n = 29) and older drivers ( n = 39) participated in a 50-minute simulated drive designed to induce fatigue, followed by four 10-minute sessions alternating between driving with and without an AMT. Younger drivers were significantly more affected by fatigue on driving performance than were older drivers but benefitted significantly from the AMT. Older drivers did not demonstrate increased driver errors with fatigue, and driving did not deteriorate significantly during participation in the AMT condition, although their speed was significantly more variable with the AMT. Consistent with earlier research, an AMT applied during fatiguing driving is effective in improving alertness and reducing driving errors in younger drivers. Importantly, older drivers were relatively unaffected by fatigue, and use of an AMT did not detrimentally affect their driving performance. These results support the potential use of an AMT as a new automotive technology to improve fatigue and promote driver safety, though the benefits of such technology may differ between different age groups.
Santin-Janin, Hugues; Hugueny, Bernard; Aubry, Philippe; Fouchet, David; Gimenez, Olivier; Pontier, Dominique
2014-01-01
Background Data collected to inform time variations in natural population size are tainted by sampling error. Ignoring sampling error in population dynamics models induces bias in parameter estimators, e.g., density-dependence. In particular, when sampling errors are independent among populations, the classical estimator of the synchrony strength (zero-lag correlation) is biased downward. However, this bias is rarely taken into account in synchrony studies although it may lead to overemphasizing the role of intrinsic factors (e.g., dispersal) with respect to extrinsic factors (the Moran effect) in generating population synchrony as well as to underestimating the extinction risk of a metapopulation. Methodology/Principal findings The aim of this paper was first to illustrate the extent of the bias that can be encountered in empirical studies when sampling error is neglected. Second, we presented a space-state modelling approach that explicitly accounts for sampling error when quantifying population synchrony. Third, we exemplify our approach with datasets for which sampling variance (i) has been previously estimated, and (ii) has to be jointly estimated with population synchrony. Finally, we compared our results to those of a standard approach neglecting sampling variance. We showed that ignoring sampling variance can mask a synchrony pattern whatever its true value and that the common practice of averaging few replicates of population size estimates poorly performed at decreasing the bias of the classical estimator of the synchrony strength. Conclusion/Significance The state-space model used in this study provides a flexible way of accurately quantifying the strength of synchrony patterns from most population size data encountered in field studies, including over-dispersed count data. We provided a user-friendly R-program and a tutorial example to encourage further studies aiming at quantifying the strength of population synchrony to account for uncertainty in population size estimates. PMID:24489839
Durg, Sharanbasappa; Veerapur, Veeresh P.; Thippeswamy, B. S.; Ahamed, Syed Mansoor
2015-01-01
Background: Śilājatu (Shilajit; SJ) is claimed in traditional Indian medical practice to be useful in the treatment of nervous disorders, epilepsy and as antistress. Aim: To investigate whether SJ possesses antiepileptic and antipsychotic activities in rodents. Materials and Methods: Isonicotinyl hydrazine (INH), pentylenetetrazole (PTZ), apomorphine, phenytoin, diazepam, haloperidol and other chemicals of analytical grade were procured from standard companies. The antiepileptic activity of SJ was assessed using maximal electro shock (MES)-induced seizures in rats, INH and PTZ-induced seizures in mice. The antipsychotic effect of SJ was evaluated using apomorphine-induced climbing and stereotyped behaviours respectively, in mice and rats. Settings and Designs: SJ (25 and 50 mg/kg, p.o.) was given orally once daily for 15 days in all the rodent models. On the test day, SJ was administered 1 h prior to electric shock or chemical inducers (INH/PTZ/apomorphine) in experimental animals; the animals were then observed for different phases of seizures and psychotic behaviours. In addition, gamma-aminobutyric acid (GABA) content in the brain of rats and mice was estimated in seizure models. Statistical Analysis: The data were expressed as mean ± standard error of mean. Statistical comparisons were performed by one-way ANOVA followed by Tukey's post-test using Graph Pad Prism version 5.0, USA. A P < 0.05 was considered significant. Results and Conclusions: SJ pretreatment significantly inhibited the seizures induced by MES, INH and PTZ in a dose dependent manner. Further, SJ augmented brain GABA levels to normal, decreased by INH and PTZ in mice brain. SJ pretreatment also significantly inhibited the climbing and stereotyped behaviours induced by apomorphine. The present data seems to confirm the antiepileptic activity of SJ which may be because of enhancing the GABAergic system. The antipsychotic activity observed may be due to anti-dopaminergic and/or GABA-mimetic actions. PMID:26865744
Peppas, Kostas P; Lazarakis, Fotis; Alexandridis, Antonis; Dangakis, Kostas
2012-08-01
In this Letter we investigate the error performance of multiple-input multiple-output free-space optical communication systems employing intensity modulation/direct detection and operating over strong atmospheric turbulence channels. Atmospheric-induced strong turbulence fading is modeled using the negative exponential distribution. For the considered system, an approximate yet accurate analytical expression for the average bit error probability is derived and an efficient method for its numerical evaluation is proposed. Numerically evaluated and computer simulation results are further provided to demonstrate the validity of the proposed mathematical analysis.
Morichi, Shinichiro; Yamanaka, Gaku; Ishida, Yu; Oana, Shingo; Kashiwagi, Yasuyo; Kawashima, Hisashi
2014-11-01
We investigated changes in the brain-derived neurotrophic factor (BDNF) and interleukin (IL)-6 levels in pediatric patients with central nervous system (CNS) infections, particularly viral infection-induced encephalopathy. Over a 5-year study period, 24 children hospitalized with encephalopathy were grouped based on their acute encephalopathy type (the excitotoxicity, cytokine storm, and metabolic error types). Children without CNS infections served as controls. In serum and cerebrospinal fluid (CSF) samples, BDNF and IL-6 levels were increased in all encephalopathy groups, and significant increases were noted in the influenza-associated and cytokine storm encephalopathy groups. Children with sequelae showed higher BDNF and IL-6 levels than those without sequelae. In pediatric patients, changes in serum and CSF BDNF and IL-6 levels may serve as a prognostic index of CNS infections, particularly for the diagnosis of encephalopathy and differentiation of encephalopathy types.
NASA Astrophysics Data System (ADS)
Luna, Aderval S.; Gonzaga, Fabiano B.; da Rocha, Werickson F. C.; Lima, Igor C. A.
2018-01-01
Laser-induced breakdown spectroscopy (LIBS) analysis was carried out on eleven steel samples to quantify the concentrations of chromium, nickel, and manganese. LIBS spectral data were correlated to known concentrations of the samples using different strategies in partial least squares (PLS) regression models. For the PLS analysis, one predictive model was separately generated for each element, while different approaches were used for the selection of variables (VIP: variable importance in projection and iPLS: interval partial least squares) in the PLS model to quantify the contents of the elements. The comparison of the performance of the models showed that there was no significant statistical difference using the Wilcoxon signed rank test. The elliptical joint confidence region (EJCR) did not detect systematic errors in these proposed methodologies for each metal.
Drach-Zahavy, A; Somech, A; Admi, H; Peterfreund, I; Peker, H; Priente, O
2014-03-01
Attention in the ward should shift from preventing medication administration errors to managing them. Nevertheless, little is known in regard with the practices nursing wards apply to learn from medication administration errors as a means of limiting them. To test the effectiveness of four types of learning practices, namely, non-integrated, integrated, supervisory and patchy learning practices in limiting medication administration errors. Data were collected from a convenient sample of 4 hospitals in Israel by multiple methods (observations and self-report questionnaires) at two time points. The sample included 76 wards (360 nurses). Medication administration error was defined as any deviation from prescribed medication processes and measured by a validated structured observation sheet. Wards' use of medication administration technologies, location of the medication station, and workload were observed; learning practices and demographics were measured by validated questionnaires. Results of the mixed linear model analysis indicated that the use of technology and quiet location of the medication cabinet were significantly associated with reduced medication administration errors (estimate=.03, p<.05 and estimate=-.17, p<.01 correspondingly), while workload was significantly linked to inflated medication administration errors (estimate=.04, p<.05). Of the learning practices, supervisory learning was the only practice significantly linked to reduced medication administration errors (estimate=-.04, p<.05). Integrated and patchy learning were significantly linked to higher levels of medication administration errors (estimate=-.03, p<.05 and estimate=-.04, p<.01 correspondingly). Non-integrated learning was not associated with it (p>.05). How wards manage errors might have implications for medication administration errors beyond the effects of typical individual, organizational and technology risk factors. Head nurse can facilitate learning from errors by "management by walking around" and monitoring nurses' medication administration behaviors. Copyright © 2013 Elsevier Ltd. All rights reserved.
Sethuraman, Usha; Kannikeswaran, Nirupama; Murray, Kyle P; Zidan, Marwan A; Chamberlain, James M
2015-06-01
Prescription errors occur frequently in pediatric emergency departments (PEDs).The effect of computerized physician order entry (CPOE) with electronic medication alert system (EMAS) on these is unknown. The objective was to compare prescription errors rates before and after introduction of CPOE with EMAS in a PED. The hypothesis was that CPOE with EMAS would significantly reduce the rate and severity of prescription errors in the PED. A prospective comparison of a sample of outpatient, medication prescriptions 5 months before and after CPOE with EMAS implementation (7,268 before and 7,292 after) was performed. Error types and rates, alert types and significance, and physician response were noted. Medication errors were deemed significant if there was a potential to cause life-threatening injury, failure of therapy, or an adverse drug effect. There was a significant reduction in the errors per 100 prescriptions (10.4 before vs. 7.3 after; absolute risk reduction = 3.1, 95% confidence interval [CI] = 2.2 to 4.0). Drug dosing error rates decreased from 8 to 5.4 per 100 (absolute risk reduction = 2.6, 95% CI = 1.8 to 3.4). Alerts were generated for 29.6% of prescriptions, with 45% involving drug dose range checking. The sensitivity of CPOE with EMAS in identifying errors in prescriptions was 45.1% (95% CI = 40.8% to 49.6%), and the specificity was 57% (95% CI = 55.6% to 58.5%). Prescribers modified 20% of the dosing alerts, resulting in the error not reaching the patient. Conversely, 11% of true dosing alerts for medication errors were overridden by the prescribers: 88 (11.3%) resulted in medication errors, and 684 (88.6%) were false-positive alerts. A CPOE with EMAS was associated with a decrease in overall prescription errors in our PED. Further system refinements are required to reduce the high false-positive alert rates. © 2015 by the Society for Academic Emergency Medicine.
Liu, Yan; Wang, Yuexin; Lv, Huibin; Jiang, Xiaodan; Zhang, Mingzhou; Li, Xuemin
2017-01-01
To investigate the efficacy of α-adrenergic agonist brimonidine either alone or combined with pirenzepine for inhibiting progressing myopia in guinea pig lens-myopia-induced models. Thirty-six guinea pigs were randomly divided into six groups: Group A received 2% pirenzepine, Group B received 0.2% brimonidine, Group C received 0.1% brimonidine, Group D received 2% pirenzepine + 0.2% brimonidine, Group E received 2% pirenzepine + 0.1% brimonidine, and Group F received the medium. Myopia was induced in the right eyes of all guinea pigs using polymethyl methacrylate (PMMA) lenses for 3 weeks. Eye drops were administered accordingly. Intraocular pressure was measured every day. Refractive error and axial length measurements were performed once a week. The enucleated eyeballs were removed for hematoxylin and eosin (H&E) and Van Gieson (VG) staining at the end of the study. The lens-induced myopia model was established after 3 weeks. Treatment with 0.1% brimonidine alone and 0.2% brimonidine alone was capable of inhibiting progressing myopia, as shown by the better refractive error (p=0.024; p=0.006) and shorter axial length (p=0.005; p=0.0017). Treatment with 0.1% brimonidine and 0.2% brimonidine combined with 2% pirenzepine was also effective in suppressing progressing refractive error (p=0.016; p=0.0006) and axial length (p=0.017; p=0.0004). The thickness of the sclera was kept stable in all groups except group F; the sclera was much thinner in the lens-induced myopia eyes compared to the control eyes. Treatment with 0.1% brimonidine alone and 0.2% brimonidine alone, as well as combined with 2% pirenzepine, was effective in inhibiting progressing myopia. The result indicates that intraocular pressure elevation is possibly a promising mechanism and potential treatment for progressing myopia.
NASA Astrophysics Data System (ADS)
Taher, K. A.; Majumder, S. P.
2017-05-01
An analytical approach is developed to find the effect of cross-polarization (XPol)-induced crosstalk on the bit error rate (BER) performance of a polarization division multiplex (PDM) quadrature phase shift keying (QPSK) optical transmission system with polarization diversity receiver. Analytical expression for the XPol-induced crosstalk and signal to crosstalk plus noise ratio (SCNR) are developed at the output of polarization diversity PDM-QPSK coherent optical homodyne receiver conditioned on a given value of mean misalignment angle. Considering Maxwellian distribution for the pdf of the misalignment angle, the average SCNR and average BER are derived. Results show that there is significant deterioration in the BER performance and power penalty due to XPol-induced crosstalk. Penalties in signal power are found to be 8.85 dB, 11.28 dB and 12.59 dB correspondingly for LO laser power of -10 dBm, -5 dBm and 0 dBm at a data rate of 100 Gbps, mean misalignment angle of 7.5 degree and BER of 10-9 compared to the signal power without crosstalk.
DNA replication error-induced extinction of diploid yeast.
Herr, Alan J; Kennedy, Scott R; Knowels, Gary M; Schultz, Eric M; Preston, Bradley D
2014-03-01
Genetic defects in DNA polymerase accuracy, proofreading, or mismatch repair (MMR) induce mutator phenotypes that accelerate adaptation of microbes and tumor cells. Certain combinations of mutator alleles synergistically increase mutation rates to levels that drive extinction of haploid cells. The maximum tolerated mutation rate of diploid cells is unknown. Here, we define the threshold for replication error-induced extinction (EEX) of diploid Saccharomyces cerevisiae. Double-mutant pol3 alleles that carry mutations for defective DNA polymerase-δ proofreading (pol3-01) and accuracy (pol3-L612M or pol3-L612G) induce strong mutator phenotypes in heterozygous diploids (POL3/pol3-01,L612M or POL3/pol3-01,L612G). Both pol3-01,L612M and pol3-01,L612G alleles are lethal in the homozygous state; cells with pol3-01,L612M divide up to 10 times before arresting at random stages in the cell cycle. Antimutator eex mutations in the pol3 alleles suppress this lethality (pol3-01,L612M,eex or pol3-01,L612G,eex). MMR defects synergize with pol3-01,L612M,eex and pol3-01,L612G,eex alleles, increasing mutation rates and impairing growth. Conversely, inactivation of the Dun1 S-phase checkpoint kinase suppresses strong pol3-01,L612M,eex and pol3-01,L612G,eex mutator phenotypes as well as the lethal pol3-01,L612M phenotype. Our results reveal that the lethal error threshold in diploids is 10 times higher than in haploids and likely determined by homozygous inactivation of essential genes. Pronounced loss of fitness occurs at mutation rates well below the lethal threshold, suggesting that mutator-driven cancers may be susceptible to drugs that exacerbate replication errors.
Nakayama, Masataka; Saito, Satoru
2015-08-01
The present study investigated principles of phonological planning, a common serial ordering mechanism for speech production and phonological short-term memory. Nakayama and Saito (2014) have investigated the principles by using a speech-error induction technique, in which participants were exposed to an auditory distracIor word immediately before an utterance of a target word. They demonstrated within-word adjacent mora exchanges and serial position effects on error rates. These findings support, respectively, the temporal distance and the edge principles at a within-word level. As this previous study induced errors using word distractors created by exchanging adjacent morae in the target words, it is possible that the speech errors are expressions of lexical intrusions reflecting interactive activation of phonological and lexical/semantic representations. To eliminate this possibility, the present study used nonword distractors that had no lexical or semantic representations. This approach successfully replicated the error patterns identified in the abovementioned study, further confirming that the temporal distance and edge principles are organizing precepts in phonological planning.
Generalized site occupancy models allowing for false positive and false negative errors
Royle, J. Andrew; Link, W.A.
2006-01-01
Site occupancy models have been developed that allow for imperfect species detection or ?false negative? observations. Such models have become widely adopted in surveys of many taxa. The most fundamental assumption underlying these models is that ?false positive? errors are not possible. That is, one cannot detect a species where it does not occur. However, such errors are possible in many sampling situations for a number of reasons, and even low false positive error rates can induce extreme bias in estimates of site occupancy when they are not accounted for. In this paper, we develop a model for site occupancy that allows for both false negative and false positive error rates. This model can be represented as a two-component finite mixture model and can be easily fitted using freely available software. We provide an analysis of avian survey data using the proposed model and present results of a brief simulation study evaluating the performance of the maximum-likelihood estimator and the naive estimator in the presence of false positive errors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saeki, Hiroshi, E-mail: saeki@spring8.or.jp; Magome, Tamotsu, E-mail: saeki@spring8.or.jp
2014-10-06
To compensate pressure-measurement errors caused by a synchrotron radiation environment, a precise method using a hot-cathode-ionization-gauge head with correcting electrode, was developed and tested in a simulation experiment with excess electrons in the SPring-8 storage ring. This precise method to improve the measurement accuracy, can correctly reduce the pressure-measurement errors caused by electrons originating from the external environment, and originating from the primary gauge filament influenced by spatial conditions of the installed vacuum-gauge head. As the result of the simulation experiment to confirm the performance reducing the errors caused by the external environment, the pressure-measurement error using this method wasmore » approximately less than several percent in the pressure range from 10{sup −5} Pa to 10{sup −8} Pa. After the experiment, to confirm the performance reducing the error caused by spatial conditions, an additional experiment was carried out using a sleeve and showed that the improved function was available.« less
A New Methodology for Vibration Error Compensation of Optical Encoders
Lopez, Jesus; Artes, Mariano
2012-01-01
Optical encoders are sensors based on grating interference patterns. Tolerances inherent to the manufacturing process can induce errors in the position accuracy as the measurement signals stand apart from the ideal conditions. In case the encoder is working under vibrations, the oscillating movement of the scanning head is registered by the encoder system as a displacement, introducing an error into the counter to be added up to graduation, system and installation errors. Behavior improvement can be based on different techniques trying to compensate the error from measurement signals processing. In this work a new “ad hoc” methodology is presented to compensate the error of the encoder when is working under the influence of vibration. The methodology is based on fitting techniques to the Lissajous figure of the deteriorated measurement signals and the use of a look up table, giving as a result a compensation procedure in which a higher accuracy of the sensor is obtained. PMID:22666067
Error-tradeoff and error-disturbance relations for incompatible quantum measurements.
Branciard, Cyril
2013-04-23
Heisenberg's uncertainty principle is one of the main tenets of quantum theory. Nevertheless, and despite its fundamental importance for our understanding of quantum foundations, there has been some confusion in its interpretation: Although Heisenberg's first argument was that the measurement of one observable on a quantum state necessarily disturbs another incompatible observable, standard uncertainty relations typically bound the indeterminacy of the outcomes when either one or the other observable is measured. In this paper, we quantify precisely Heisenberg's intuition. Even if two incompatible observables cannot be measured together, one can still approximate their joint measurement, at the price of introducing some errors with respect to the ideal measurement of each of them. We present a tight relation characterizing the optimal tradeoff between the error on one observable vs. the error on the other. As a particular case, our approach allows us to characterize the disturbance of an observable induced by the approximate measurement of another one; we also derive a stronger error-disturbance relation for this scenario.
Huckels-Baumgart, Saskia; Baumgart, André; Buschmann, Ute; Schüpfer, Guido; Manser, Tanja
2016-12-21
Interruptions and errors during the medication process are common, but published literature shows no evidence supporting whether separate medication rooms are an effective single intervention in reducing interruptions and errors during medication preparation in hospitals. We tested the hypothesis that the rate of interruptions and reported medication errors would decrease as a result of the introduction of separate medication rooms. Our aim was to evaluate the effect of separate medication rooms on interruptions during medication preparation and on self-reported medication error rates. We performed a preintervention and postintervention study using direct structured observation of nurses during medication preparation and daily structured medication error self-reporting of nurses by questionnaires in 2 wards at a major teaching hospital in Switzerland. A volunteer sample of 42 nurses was observed preparing 1498 medications for 366 patients over 17 hours preintervention and postintervention on both wards. During 122 days, nurses completed 694 reporting sheets containing 208 medication errors. After the introduction of the separate medication room, the mean interruption rate decreased significantly from 51.8 to 30 interruptions per hour (P < 0.01), and the interruption-free preparation time increased significantly from 1.4 to 2.5 minutes (P < 0.05). Overall, the mean medication error rate per day was also significantly reduced after implementation of the separate medication room from 1.3 to 0.9 errors per day (P < 0.05). The present study showed the positive effect of a hospital-based intervention; after the introduction of the separate medication room, the interruption and medication error rates decreased significantly.
Analysis of operator splitting errors for near-limit flame simulations
NASA Astrophysics Data System (ADS)
Lu, Zhen; Zhou, Hua; Li, Shan; Ren, Zhuyin; Lu, Tianfeng; Law, Chung K.
2017-04-01
High-fidelity simulations of ignition, extinction and oscillatory combustion processes are of practical interest in a broad range of combustion applications. Splitting schemes, widely employed in reactive flow simulations, could fail for stiff reaction-diffusion systems exhibiting near-limit flame phenomena. The present work first employs a model perfectly stirred reactor (PSR) problem with an Arrhenius reaction term and a linear mixing term to study the effects of splitting errors on the near-limit combustion phenomena. Analysis shows that the errors induced by decoupling of the fractional steps may result in unphysical extinction or ignition. The analysis is then extended to the prediction of ignition, extinction and oscillatory combustion in unsteady PSRs of various fuel/air mixtures with a 9-species detailed mechanism for hydrogen oxidation and an 88-species skeletal mechanism for n-heptane oxidation, together with a Jacobian-based analysis for the time scales. The tested schemes include the Strang splitting, the balanced splitting, and a newly developed semi-implicit midpoint method. Results show that the semi-implicit midpoint method can accurately reproduce the dynamics of the near-limit flame phenomena and it is second-order accurate over a wide range of time step size. For the extinction and ignition processes, both the balanced splitting and midpoint method can yield accurate predictions, whereas the Strang splitting can lead to significant shifts on the ignition/extinction processes or even unphysical results. With an enriched H radical source in the inflow stream, a delay of the ignition process and the deviation on the equilibrium temperature are observed for the Strang splitting. On the contrary, the midpoint method that solves reaction and diffusion together matches the fully implicit accurate solution. The balanced splitting predicts the temperature rise correctly but with an over-predicted peak. For the sustainable and decaying oscillatory combustion from cool flames, both the Strang splitting and the midpoint method can successfully capture the dynamic behavior, whereas the balanced splitting scheme results in significant errors.
Analysis of operator splitting errors for near-limit flame simulations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Zhen; Zhou, Hua; Li, Shan
High-fidelity simulations of ignition, extinction and oscillatory combustion processes are of practical interest in a broad range of combustion applications. Splitting schemes, widely employed in reactive flow simulations, could fail for stiff reaction–diffusion systems exhibiting near-limit flame phenomena. The present work first employs a model perfectly stirred reactor (PSR) problem with an Arrhenius reaction term and a linear mixing term to study the effects of splitting errors on the near-limit combustion phenomena. Analysis shows that the errors induced by decoupling of the fractional steps may result in unphysical extinction or ignition. The analysis is then extended to the prediction ofmore » ignition, extinction and oscillatory combustion in unsteady PSRs of various fuel/air mixtures with a 9-species detailed mechanism for hydrogen oxidation and an 88-species skeletal mechanism for n-heptane oxidation, together with a Jacobian-based analysis for the time scales. The tested schemes include the Strang splitting, the balanced splitting, and a newly developed semi-implicit midpoint method. Results show that the semi-implicit midpoint method can accurately reproduce the dynamics of the near-limit flame phenomena and it is second-order accurate over a wide range of time step size. For the extinction and ignition processes, both the balanced splitting and midpoint method can yield accurate predictions, whereas the Strang splitting can lead to significant shifts on the ignition/extinction processes or even unphysical results. With an enriched H radical source in the inflow stream, a delay of the ignition process and the deviation on the equilibrium temperature are observed for the Strang splitting. On the contrary, the midpoint method that solves reaction and diffusion together matches the fully implicit accurate solution. The balanced splitting predicts the temperature rise correctly but with an over-predicted peak. For the sustainable and decaying oscillatory combustion from cool flames, both the Strang splitting and the midpoint method can successfully capture the dynamic behavior, whereas the balanced splitting scheme results in significant errors.« less
Localized landslide risk assessment with multi pass L band DInSAR analysis
NASA Astrophysics Data System (ADS)
Yun, HyeWon; Rack Kim, Jung; Lin, Shih-Yuan; Choi, YunSoo
2014-05-01
In terms of data availability and error correction, landslide forecasting by Differential Interferometric SAR (DInSAR) analysis is not easy task. Especially, the landslides by the anthropogenic construction activities frequently occurred in the localized cutting side of mountainous area. In such circumstances, it is difficult to attain sufficient enough accuracy because of the external factors inducing the error component in electromagnetic wave propagation. For instance, the local climate characteristics such as orographic effect and the proximity to water source can produce the significant anomalies in the water vapor distribution and consequently result in the error components of InSAR phase angle measurements. Moreover the high altitude parts of target area cause the stratified tropospheric delay error in DInSAR measurement. The other obstacle in DInSAR observation over the potential landside site is the vegetation canopy which causes the decorrelation of InSAR phase. Thus rather than C band sensor such as ENVISAT, ERS and RADARSAT, DInSAR analysis with L band ALOS PLASAR is more recommendable. Together with the introduction of L band DInSAR analysis, the improved DInSAR technique to cope all above obstacles is necessary. Thus we employed two approaches i.e. StaMPS/MTI (Stanford Method for Persistent Scatterers/Multi-Temporal InSAR, Hopper et al., 2007) which was newly developed for extracting the reliable deformation values through time series analysis and two pass DInSAR with the error term compensation based on the external weather information in this study. Since the water vapor observation from spaceborne radiometer is not feasible by the temporal gap in this case, the quantities from weather Research Forecasting (WRF) with 1 km spatial resolution was used to address the atmospheric phase error in two pass DInSAR analysis. Also it was observed that base DEM offset with time dependent perpendicular baselines of InSAR time series produce a significant error even in the advanced time series techniques such as StaMPS/MTI. We tried to compensate with the algorithmic base together with the usage of high resolution LIDAR DEM. The target area of this study is the eastern part of Korean peninsula centered. In there, the landslide originated by the geomorphic factors such as high sloped topography and localized torrential down pour is critical issue. The surface deformations from error corrected two pass DInSAR and StaMPS/MTI are crossly compared and validated with the landslide triggering factors such as vegetation, slope and geological properties. The study will be further extended for the application of future SAR sensors by incorporating the dynamic analysis of topography to implement practical landslide forecasting scheme.
Casellato, Claudia; Pedrocchi, Alessandra; Zorzi, Giovanna; Rizzi, Giorgio; Ferrigno, Giancarlo; Nardocci, Nardo
2012-07-23
Robot-generated deviating forces during multijoint reaching movements have been applied to investigate motor control and to tune neuromotor adaptation. Can the application of force to limbs improve motor learning? In this framework, the response to altered dynamic environments of children affected by primary dystonia has never been studied. As preliminary pilot study, eleven children with primary dystonia and eleven age-matched healthy control subjects were asked to perform upper limb movements, triangle-reaching (three directions) and circle-writing, using a haptic robot interacting with ad-hoc developed task-specific visual interfaces. Three dynamic conditions were provided, null additive external force (A), constant disturbing force (B) and deactivation of the additive external force again (C). The path length for each trial was computed, from the recorded position data and interaction events. The results show that the disturbing force affects significantly the movement outcomes in healthy but not in dystonic subjects, already compromised in the reference condition: the external alteration uncalibrates the healthy sensorimotor system, while the dystonic one is already strongly uncalibrated. The lack of systematic compensation for perturbation effects during B condition is reflected into the absence of after-effects in C condition, which would be the evidence that CNS generates a prediction of the perturbing forces using an internal model of the environment.The most promising finding is that in dystonic population the altered dynamic exposure seems to induce a subsequent improvement, i.e. a beneficial after-effect in terms of optimal path control, compared with the correspondent reference movement outcome. The short-time error-enhancing training in dystonia could represent an effective approach for motor performance improvement, since the exposure to controlled dynamic alterations induces a refining of the existing but strongly imprecise motor scheme and sensorimotor patterns.
2012-01-01
Background Robot-generated deviating forces during multijoint reaching movements have been applied to investigate motor control and to tune neuromotor adaptation. Can the application of force to limbs improve motor learning? In this framework, the response to altered dynamic environments of children affected by primary dystonia has never been studied. Methods As preliminary pilot study, eleven children with primary dystonia and eleven age-matched healthy control subjects were asked to perform upper limb movements, triangle-reaching (three directions) and circle-writing, using a haptic robot interacting with ad-hoc developed task-specific visual interfaces. Three dynamic conditions were provided, null additive external force (A), constant disturbing force (B) and deactivation of the additive external force again (C). The path length for each trial was computed, from the recorded position data and interaction events. Results The results show that the disturbing force affects significantly the movement outcomes in healthy but not in dystonic subjects, already compromised in the reference condition: the external alteration uncalibrates the healthy sensorimotor system, while the dystonic one is already strongly uncalibrated. The lack of systematic compensation for perturbation effects during B condition is reflected into the absence of after-effects in C condition, which would be the evidence that CNS generates a prediction of the perturbing forces using an internal model of the environment. The most promising finding is that in dystonic population the altered dynamic exposure seems to induce a subsequent improvement, i.e. a beneficial after-effect in terms of optimal path control, compared with the correspondent reference movement outcome. Conclusions The short-time error-enhancing training in dystonia could represent an effective approach for motor performance improvement, since the exposure to controlled dynamic alterations induces a refining of the existing but strongly imprecise motor scheme and sensorimotor patterns. PMID:22824547
NASA Astrophysics Data System (ADS)
Zhang, X.; Anagnostou, E. N.; Schwartz, C. S.
2017-12-01
Satellite precipitation products tend to have significant biases over complex terrain. Our research investigates a statistical approach for satellite precipitation adjustment based solely on numerical weather simulations. This approach has been evaluated in two mid-latitude (Zhang et al. 2013*1, Zhang et al. 2016*2) and three topical mountainous regions by using the WRF model to adjust two high-resolution satellite products i) National Oceanic and Atmospheric Administration (NOAA) Climate Prediction Center morphing technique (CMORPH) and ii) Global Satellite Mapping of Precipitation (GSMaP). Results show the adjustment effectively reduces the satellite underestimation of high rain rates, which provides a solid proof-of-concept for continuing research of NWP-based satellite correction. In this study we investigate the feasibility of using NCAR Real-time Ensemble Forecasts*3 for adjusting near-real-time satellite precipitation datasets over complex terrain areas in the Continental United States (CONUS) such as Olympic Peninsula, California coastal mountain ranges, Rocky Mountains and South Appalachians. The research will focus on flood-inducing storms occurred from May 2015 to December 2016 and four satellite precipitation products (CMORPH, GSMaP, PERSIANN-CCS and IMERG). The error correction performance evaluation will be based on comparisons against the gauge-adjusted Stage IV precipitation data. *1 Zhang, Xinxuan, et al. "Using NWP simulations in satellite rainfall estimation of heavy precipitation events over mountainous areas." Journal of Hydrometeorology 14.6 (2013): 1844-1858. *2 Zhang, Xinxuan, et al. "Hydrologic Evaluation of NWP-Adjusted CMORPH Estimates of Hurricane-Induced Precipitation in the Southern Appalachians." Journal of Hydrometeorology 17.4 (2016): 1087-1099. *3 Schwartz, Craig S., et al. "NCAR's experimental real-time convection-allowing ensemble prediction system." Weather and Forecasting 30.6 (2015): 1645-1654.
NASA Astrophysics Data System (ADS)
Lazic, V.; De Ninno, A.
2017-11-01
The laser induced plasma spectroscopy was applied on particles attached on substrate represented by a silica wafer covered with a thin oil film. The substrate itself weakly interacts with a ns Nd:YAG laser (1064 nm) while presence of particles strongly enhances the plasma emission, here detected by a compact spectrometer array. Variations of the sample mass from one laser spot to another exceed one order of magnitude, as estimated by on-line photography and the initial image calibration for different sample loadings. Consequently, the spectral lines from particles show extreme intensity fluctuations from one sampling point to another, between the detection threshold and the detector's saturation in some cases. In such conditions the common calibration approach based on the averaged spectra, also when considering ratios of the element lines i.e. concentrations, produces errors too large for measuring the sample compositions. On the other hand, intensities of an analytical and the reference line from single shot spectra are linearly correlated. The corresponding slope depends on the concentration ratio and it is weakly sensitive to fluctuations of the plasma temperature inside the data set. A use of the slopes for constructing the calibration graphs significantly reduces the error bars but it does not eliminate the point scattering caused by the matrix effect, which is also responsible for large differences in the average plasma temperatures among the samples. Well aligned calibration points were obtained after identifying the couples of transitions less sensitive to variations of the plasma temperature, and this was achieved by simple theoretical simulations. Such selection of the analytical lines minimizes the matrix effect, and together with the chosen calibration approach, allows to measure the relative element concentrations even in highly unstable laser induced plasmas.
NASA Technical Reports Server (NTRS)
Thurman, Sam W.; Estefan, Jeffrey A.
1991-01-01
Approximate analytical models are developed and used to construct an error covariance analysis for investigating the range of orbit determination accuracies which might be achieved for typical Mars approach trajectories. The sensitivity or orbit determination accuracy to beacon/orbiter position errors and to small spacecraft force modeling errors is also investigated. The results indicate that the orbit determination performance obtained from both Doppler and range data is a strong function of the inclination of the approach trajectory to the Martian equator, for surface beacons, and for orbiters, the inclination relative to the orbital plane. Large variations in performance were also observed for different approach velocity magnitudes; Doppler data in particular were found to perform poorly in determining the downtrack (along the direction of flight) component of spacecraft position. In addition, it was found that small spacecraft acceleration modeling errors can induce large errors in the Doppler-derived downtrack position estimate.
NASA Astrophysics Data System (ADS)
Liu, Wei; Sneeuw, Nico; Jiang, Weiping
2017-04-01
GRACE mission has contributed greatly to the temporal gravity field monitoring in the past few years. However, ocean tides cause notable alias errors for single-pair spaceborne gravimetry missions like GRACE in two ways. First, undersampling from satellite orbit induces the aliasing of high-frequency tidal signals into the gravity signal. Second, ocean tide models used for de-aliasing in the gravity field retrieval carry errors, which will directly alias into the recovered gravity field. GRACE satellites are in non-repeat orbit, disabling the alias error spectral estimation based on the repeat period. Moreover, the gravity field recovery is conducted in non-strictly monthly interval and has occasional gaps, which result in an unevenly sampled time series. In view of the two aspects above, we investigate the data-driven method to mitigate the ocean tide alias error in a post-processing mode.
García-García, Isabel; Zeighami, Yashar; Dagher, Alain
2017-06-01
Surprises are important sources of learning. Cognitive scientists often refer to surprises as "reward prediction errors," a parameter that captures discrepancies between expectations and actual outcomes. Here, we integrate neurophysiological and functional magnetic resonance imaging (fMRI) results addressing the processing of reward prediction errors and how they might be altered in drug addiction and Parkinson's disease. By increasing phasic dopamine responses, drugs might accentuate prediction error signals, causing increases in fMRI activity in mesolimbic areas in response to drugs. Chronic substance dependence, by contrast, has been linked with compromised dopaminergic function, which might be associated with blunted fMRI responses to pleasant non-drug stimuli in mesocorticolimbic areas. In Parkinson's disease, dopamine replacement therapies seem to induce impairments in learning from negative outcomes. The present review provides a holistic overview of reward prediction errors across different pathologies and might inform future clinical strategies targeting impulsive/compulsive disorders.
Using a Commercial Ethernet PHY Device in a Radiation Environment
NASA Technical Reports Server (NTRS)
Parks, Jeremy; Arani, Michael; Arroyo, Roberto
2014-01-01
This work involved placing a commercial Ethernet PHY on its own power boundary, with limited current supply, and providing detection methods to determine when the device is not operating and when it needs either a reset or power-cycle. The device must be radiation-tested and free of destructive latchup errors. The commercial Ethernet PHY's own power boundary must be supplied by a current-limited power regulator that must have an enable (for power cycling), and its maximum power output must not exceed the PHY's input requirements, thus preventing damage to the device. A regulator with configurable output limits and short-circuit protection (such as the RHFL4913, rad hard positive voltage regulator family) is ideal. This will prevent a catastrophic failure due to radiation (such as a short between the commercial device's power and ground) from taking down the board's main power. Logic provided on the board will detect errors in the PHY. An FPGA (field-programmable gate array) with embedded Ethernet MAC (Media Access Control) will work well. The error detection includes monitoring the PHY's interrupt line, and the status of the Ethernet's switched power. When the PHY is determined to be non-functional, the logic device resets the PHY, which will often clear radiation induced errors. If this doesn't work, the logic device power-cycles the FPGA by toggling the regulator's enable input. This should clear almost all radiation induced errors provided the device is not latched up.
Reliability of Memories Protected by Multibit Error Correction Codes Against MBUs
NASA Astrophysics Data System (ADS)
Ming, Zhu; Yi, Xiao Li; Chang, Liu; Wei, Zhang Jian
2011-02-01
As technology scales, more and more memory cells can be placed in a die. Therefore, the probability that a single event induces multiple bit upsets (MBUs) in adjacent memory cells gets greater. Generally, multibit error correction codes (MECCs) are effective approaches to mitigate MBUs in memories. In order to evaluate the robustness of protected memories, reliability models have been widely studied nowadays. Instead of irradiation experiments, the models can be used to quickly evaluate the reliability of memories in the early design. To build an accurate model, some situations should be considered. Firstly, when MBUs are presented in memories, the errors induced by several events may overlap each other, which is more frequent than single event upset (SEU) case. Furthermore, radiation experiments show that the probability of MBUs strongly depends on angles of the radiation event. However, reliability models which consider the overlap of multiple bit errors and angles of radiation event have not been proposed in the present literature. In this paper, a more accurate model of memories with MECCs is presented. Both the overlap of multiple bit errors and angles of event are considered in the model, which produces a more precise analysis in the calculation of mean time to failure (MTTF) for memory systems under MBUs. In addition, memories with scrubbing and nonscrubbing are analyzed in the proposed model. Finally, we evaluate the reliability of memories under MBUs in Matlab. The simulation results verify the validity of the proposed model.
The effect of monetary punishment on error evaluation in a Go/No-go task.
Maruo, Yuya; Sommer, Werner; Masaki, Hiroaki
2017-10-01
Little is known about the effects of the motivational significance of errors in Go/No-go tasks. We investigated the impact of monetary punishment on the error-related negativity (ERN) and error positivity (Pe) for both overt errors and partial errors, that is, no-go trials without overt responses but with covert muscle activities. We compared high and low punishment conditions where errors were penalized with 50 or 5 yen, respectively, and a control condition without monetary consequences for errors. Because we hypothesized that the partial-error ERN might overlap with the no-go N2, we compared ERPs between correct rejections (i.e., successful no-go trials) and partial errors in no-go trials. We also expected that Pe amplitudes should increase with the severity of the penalty for errors. Mean error rates were significantly lower in the high punishment than in the control condition. Monetary punishment did not influence the overt-error ERN and partial-error ERN in no-go trials. The ERN in no-go trials did not differ between partial errors and overt errors; in addition, ERPs for correct rejections in no-go trials without partial errors were of the same size as in go-trial. Therefore the overt-error ERN and the partial-error ERN may share similar error monitoring processes. Monetary punishment increased Pe amplitudes for overt errors, suggesting enhanced error evaluation processes. For partial errors an early Pe was observed, presumably representing inhibition processes. Interestingly, even partial errors elicited the Pe, suggesting that covert erroneous activities could be detected in Go/No-go tasks. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Engineering evaluations and studies. Report for IUS studies
NASA Technical Reports Server (NTRS)
1981-01-01
The reviews, investigations, and analyses of the Inertial Upper Stage (IUS) Spacecraft Tracking and Data Network (STDN) transponder are reviewed. Carrier lock detector performance for Tracking and Data Relay Satellite System (TDRSS) dual-mode operation is discussed, as is the problem of predicting instantaneous frequency error in the carrier loop. Coastal loop performance analysis is critiqued and the static tracking phase error induced by thermal noise biases is discussed.
Adaptive Harmonic Balance Method for Unsteady, Nonlinear, One-Dimensional Periodic Flows
2002-09-01
Design and Implemen- tation. May 1999. REF-2 23. Toro , Eleuterio F . Fiemann Solvers and Numerical Methods for Fluid Dynamics, chapter 15. New York...prominent for high-frequency unsteady-flows. Experimental Analysis of Splitting-induced Error To assess the actual effect of splitting error on a...VITA-1 vi List of Figures Figure Page 1.1. Experimental Pressure Data on Inlet Guide Vane Upstream of Transonic Rotating
Nickla, Debora L; Sharda, Vandhana; Troilo, David
2005-04-01
In chicks, the temporal response characteristics to form deprivation and to spectacle lens wear (myopic and hyperopic defocus) show essential differences, suggesting that the emmetropization system "weights" the visual signals differently. To further explore how the eye integrates opposing visual signals, we examined the responses to myopic defocus induced by prior form deprivation vs. that induced by positive spectacle lenses, in both cases alternating with form deprivation. Three experimental paradigms were used: 1) Form deprivation was induced by monocular occluders for 7 days. Over the subsequent 7 days, the occluders were removed daily for 12 hours (n = 13), 4 hours (n = 7), 2 hours (n = 7), or 0 hours (n = 6). 2) Birds were form-deprived on day 12. Over the subsequent 7 days, occluders were replaced with a +10 D lens for 2 hours per day (n = 13). 3) Starting at day 11, a +10 D lens was placed over one eye for 2 hours (n = 13), 3 hours (n = 5), or 6 hours (n = 10) per day and were otherwise untreated. Ocular dimensions were measured with high-frequency A-scan ultrasonography; refractive errors were measured by streak retinoscopy at various intervals. In recovering eyes, 2 hours per day of myopic defocus was as effective as 12 hours at inducing refractive and axial recovery (change in refractive error: +10 D vs. +13 D, respectively). By contrast, 2 hours of lens-induced defocus (alternating with form deprivation) was not sufficient to induce refractive or axial compensation (change in refractive error: -1.7 D). When myopic defocus alternated with unrestricted vision, 6 hours per day were sufficient to induce nearly full compensation (2 hours vs. 6 hours: 4.4 D vs. 8.2 D; p < 0.0005). Choroids showed rapid increases in thickness to the daily episodes of myopic defocus; these resulted in "long-term" thickness changes in recovering eyes and eyes wearing lenses for 3 or 6 hours per day. The response to myopic defocus induced by prior form deprivation is more robust than the response induced by positive lenses, suggesting that the underlying mechanisms differ. Presumably, this difference is related to the size of the eye at the onset. Compensatory decreases in growth rate occur without full compensatory choroidal thickening.
NASA Technical Reports Server (NTRS)
Blucker, T. J.; Ferry, W. W.
1971-01-01
An error model is described for the Apollo 15 sun compass, a contingency navigational device. Field test data are presented along with significant results of the test. The errors reported include a random error resulting from tilt in leveling the sun compass, a random error because of observer sighting inaccuracies, a bias error because of mean tilt in compass leveling, a bias error in the sun compass itself, and a bias error because the device is leveled to the local terrain slope.
Hashim, Syaratul-Emma; Tan, Hui-Ken; Wan-Hazabbah, W H; Ibrahim, Mohtar
2008-11-01
Refractive error remains one of the primary causes of visual impairment in children worldwide, and the prevalence of refractive error varies widely. The objective of this study was to determine the prevalence of refractive error and study the possible associated factors inducing refractive error among primary school children of Malay ethnicity in the suburban area of Kota Bharu, Kelantan, Malaysia. A school-based cross-sectional study was performed from January to July 2006 by random selection on Standard 1 to Standard 6 students of 10 primary schools in the Kota Bharu district. Visual acuity assessment was measured using logMAR ETDRS chart. Positive predictive value of uncorrected visual acuity equal or worse than 20/40, was used as a cut-off point for further evaluation by automated refraction and retinoscopic refraction. A total of 840 students were enumerated but only 705 were examined. The prevalence of uncorrected visual impairment was seen in 54 (7.7%) children. The main cause of the uncorrected visual impairment was refractive error which contributed to 90.7% of the total, and with 7.0% prevalence for the studied population. Myopia is the most common type of refractive error among children aged 6 to 12 years with prevalence of 5.4%, followed by hyperopia at 1.0% and astigmatism at 0.6%. A significant positive correlation was noted between myopia development with increasing age (P <0.005), more hours spent on reading books (P <0.005) and background history of siblings with glasses (P <0.005) and whose parents are of higher educational level (P <0.005). Malays in suburban Kelantan (5.4%) have the lowest prevalence of myopia compared with Malays in the metropolitan cities of Kuala Lumpur (9.2%) and Singapore (22.1%). The ethnicity-specific prevalence rate of myopia was the lowest among Malays in Kota Bharu, followed by Kuala Lumpur, and is the highest among Singaporean Malays. Better socio-economic factors could have contributed to higher myopia rates in the cities, since the genetic background of these ethnic Malays are similar.
On-ground calibration of the Hitomi Hard X-ray Telescopes
NASA Astrophysics Data System (ADS)
Mori, Hideyuki; Miyazawa, Takuya; Awaki, Hisamitsu; Matsumoto, Hironori; Babazaki, Yasunori; Bandai, Ayako; Demoto, Tadatsugu; Furuzawa, Akihiro; Haba, Yoshito; Hayashi, Takayuki; Iizuka, Ryo; Ishibashi, Kazunori; Ishida, Manabu; Ishida, Naoki; Itoh, Masayuki; Iwase, Toshihiro; Kato, Hiroyoshi; Kobayashi, Hiroaki; Kosaka, Tatsuro; Kunieda, Hideyo; Kurashima, Shou; Kurihara, Daichi; Kuroda, Yuuji; Maeda, Yoshitomo; Meshino, Yoshifumi; Mitsuishi, Ikuyuki; Miyata, Yuusuke; Nagano, Housei; Namba, Yoshiharu; Ogasaka, Yasushi; Ogi, Keiji; Okajima, Takashi; Saji, Shigetaka; Shimasaki, Fumiya; Sato, Takuro; Sato, Toshiki; Shima, Naotsugu; Sugita, Satoshi; Suzuki, Yoshio; Tachibana, Kenji; Tachibana, Sasagu; Takizawa, Shun'ya; Tamura, Keisuke; Tawara, Yuzuru; Tomikawa, Kazuki; Torii, Tatsuharu; Uesugi, Kentaro; Yamashita, Koujun; Yamauchi, Shigeo
2018-01-01
We present x-ray characteristics of the Hard X-ray Telescopes (HXTs) on board the Hitomi (ASTRO-H) satellite. Measurements were conducted at the SPring-8 BL20B2 beamline and the ISAS/JAXA 27-m beamline. The angular resolution defined by a half-power diameter was 1.9‧ (HXT-1) and 2.1‧ (HXT-2) at 8 keV, 1.9‧ at 30 keV, and 1.8‧ at 50 keV. The effective area was found to be 620 cm2 at 8 keV, 178 cm2 at 30 keV, and 82 cm2 at 50 keV per mirror module. Although the angular resolutions were slightly worse than the requirement (1.7‧), the effective areas sufficiently exceeded the requirements of 150 cm2 at 30 keV and 55 cm2 at 50 keV. The off-axis measurements of the effective areas resulted in the field of view being 6.1‧ at 50 keV, 7.7‧ at 30 keV, and 9.7‧ at 8 keV in diameter. We confirmed that the main component of the stray x-ray light was significantly reduced by mounting the precollimator as designed. Detailed analysis of the data revealed that the angular resolution was degraded mainly by figure errors of mirror foils, and the angular resolution is completely explained by the figure errors, positioning errors of the foils, and conical approximation of the foil shape. We found that the effective areas were ˜80% of the designed values below 40 keV, whereas they steeply decline above 40 keV and become only ˜50%. We investigated this abrupt decline and found that neither the error of the multilayer design nor the errors of the incident angles induced by the positioning errors of the foils can be the cause. The reflection profile of each foil pair from the defocused image strongly suggests that the figure errors of the foils probably bring about the reduction in the effective areas at higher energies.
Significant and Sustained Reduction in Chemotherapy Errors Through Improvement Science.
Weiss, Brian D; Scott, Melissa; Demmel, Kathleen; Kotagal, Uma R; Perentesis, John P; Walsh, Kathleen E
2017-04-01
A majority of children with cancer are now cured with highly complex chemotherapy regimens incorporating multiple drugs and demanding monitoring schedules. The risk for error is high, and errors can occur at any stage in the process, from order generation to pharmacy formulation to bedside drug administration. Our objective was to describe a program to eliminate errors in chemotherapy use among children. To increase reporting of chemotherapy errors, we supplemented the hospital reporting system with a new chemotherapy near-miss reporting system. After the model for improvement, we then implemented several interventions, including a daily chemotherapy huddle, improvements to the preparation and delivery of intravenous therapy, headphones for clinicians ordering chemotherapy, and standards for chemotherapy administration throughout the hospital. Twenty-two months into the project, we saw a centerline shift in our U chart of chemotherapy errors that reached the patient from a baseline rate of 3.8 to 1.9 per 1,000 doses. This shift has been sustained for > 4 years. In Poisson regression analyses, we found an initial increase in error rates, followed by a significant decline in errors after 16 months of improvement work ( P < .001). After the model for improvement, our improvement efforts were associated with significant reductions in chemotherapy errors that reached the patient. Key drivers for our success included error vigilance through a huddle, standardization, and minimization of interruptions during ordering.
The influence of LED lighting on task accuracy: time of day, gender and myopia effects
NASA Astrophysics Data System (ADS)
Rao, Feng; Chan, A. H. S.; Zhu, Xi-Fang
2017-07-01
In this research, task errors were obtained during performance of a marker location task in which the markers were shown on a computer screen under nine LED lighting conditions; three illuminances (100, 300 and 500 lx) and three color temperatures (3000, 4500 and 6500 K). A total of 47 students participated voluntarily in these tasks. The results showed that task errors in the morning were small and nearly constant across the nine lighting conditions. However in the afternoon, the task errors were significantly larger and varied across lighting conditions. The largest errors for the afternoon session occurred when the color temperature was 4500 K and illuminance 500 lx. There were significant differences between task errors in the morning and afternoon sessions. No significant difference between females and males was found. Task errors for high myopia students were significantly larger than for the low myopia students under the same lighting conditions. In summary, the influence of LED lighting on task accuracy during office hours was not gender dependent, but was time of day and myopia dependent.
Numerical calculation of ion polarization in the NICA collider
NASA Astrophysics Data System (ADS)
Kovalenko, A. D.; Butenko, A. V.; Kekelidze, V. D.; Mikhaylov, V. A.; Kondratenko, M. A.; Kondratenko, A. M.; Filatov, Yu N.
2016-02-01
The NICA Collider with two solenoid Siberian snakes is “transparent” to the spin. The collider transparent to the spin provides a unique capability to control any polarization direction of protons and deuterons using additional weak solenoids without affecting orbital parameters of the beam. The spin tune induced by the control solenoids must significantly exceed the strength of the zero-integer spin resonance, which contains a coherent part associated with errors in the collider's magnetic structure and an incoherent part associated with the beam emittances. We present calculations of the coherent part of the resonance strength in the NICA collider for proton and deuteron beams.
Resonance in the dynamics of chemical systems simulated by the implicit midpoint scheme
NASA Astrophysics Data System (ADS)
Mandziuk, Margaret; Schlick, Tamar
1995-05-01
The numerical behavior of the symplectic, implicit midpoint method with a wide range of integration timesteps is examined through an application to a diatomic molecule governed by a Morse potential. Our oscillator with a 12.6 fs period exhibits notable, integrator induced, timestep- ( Δt) dependent resonances and we predict approximate values of Δt where they will occur. The particular case of a third-order resonance ( Δt ≈ 7 fs here) leads to instability, and higher-order resonances ( n = 4, 5) to large energetic fluctuations and/or corrupted phase diagrams. Significantly, for Δt > 10 fs the energy errors remain bound.
Anti-retroviral therapy-induced status epilepticus in "pseudo-HIV serodeconversion".
Etgen, Thorleif; Eberl, Bernhard; Freudenberger, Thomas
2010-01-01
Diligence in the interpretation of results is essential as information gained from the psychiatric patient's history might often be restricted. Nonobservance of established guidelines may lead to a wrong diagnosis, induce a false therapy and result in life-threatening situations. Communication errors between hospitals and doctors and uncritical acceptance of prior diagnoses add substantially to this problem. We present a patient with alcohol-related dementia who received anti-retroviral therapy that promoted a non-convulsive status epilepticus. HIV serodeconversion was considered after our laboratory result yielded a HIV-negative status. Critical review of previous diagnostic investigations revealed several errors in the diagnosis of HIV infection leading to a "pseudo-serodeconversion." Finally, anti-retroviral therapy could be discontinued. Copyright © 2010 Elsevier Inc. All rights reserved.
Managing human fallibility in critical aerospace situations
NASA Astrophysics Data System (ADS)
Tew, Larry
2014-11-01
Human fallibility is pervasive in the aerospace industry with over 50% of errors attributed to human error. Consider the benefits to any organization if those errors were significantly reduced. Aerospace manufacturing involves high value, high profile systems with significant complexity and often repetitive build, assembly, and test operations. In spite of extensive analysis, planning, training, and detailed procedures, human factors can cause unexpected errors. Handling such errors involves extensive cause and corrective action analysis and invariably schedule slips and cost growth. We will discuss success stories, including those associated with electro-optical systems, where very significant reductions in human fallibility errors were achieved after receiving adapted and specialized training. In the eyes of company and customer leadership, the steps used to achieve these results lead to in a major culture change in both the workforce and the supporting management organization. This approach has proven effective in other industries like medicine, firefighting, law enforcement, and aviation. The roadmap to success and the steps to minimize human error are known. They can be used by any organization willing to accept human fallibility and take a proactive approach to incorporate the steps needed to manage and minimize error.
Kessels, Roy P C; van Loon, Eke; Wester, Arie J
2007-10-01
To examine the errorless learning approach using a procedural memory task (i.e. learning of actual routes) in patients with amnesia, as compared to trial-and-error learning. Counterbalanced self-controlled cases series. Psychiatric hospital (Korsakoff clinic). A convenience sample of 10 patients with the Korsakoff amnestic syndrome. All patients learned a route in four sessions on separate days using an errorless approach and a different route using trial-and-error. Error rate was scored during route learning and standard neuro-psychological tests were administered (i.e. subtest route recall of the Rivermead Behavioural Memory Test (RBMT) and the Dutch version of the California Verbal Learning Test (VLGT)). A significant learning effect was found in the trial-and-error condition over consecutive sessions (P = 0.006), but no performance difference was found between errorless and trial-and-error learning of the routes. VLGT performance was significantly correlated with a trial-and-error advantage (P < 0.05); no significant correlation was found between the RBMT subtest and the learning conditions. Errorless learning was no more successful than trial-and-error learning of a procedural spatial task in patients with the Korsakoff syndrome (severe amnesia).
Impact of an antiretroviral stewardship strategy on medication error rates.
Shea, Katherine M; Hobbs, Athena Lv; Shumake, Jason D; Templet, Derek J; Padilla-Tolentino, Eimeira; Mondy, Kristin E
2018-05-02
The impact of an antiretroviral stewardship strategy on medication error rates was evaluated. This single-center, retrospective, comparative cohort study included patients at least 18 years of age infected with human immunodeficiency virus (HIV) who were receiving antiretrovirals and admitted to the hospital. A multicomponent approach was developed and implemented and included modifications to the order-entry and verification system, pharmacist education, and a pharmacist-led antiretroviral therapy checklist. Pharmacists performed prospective audits using the checklist at the time of order verification. To assess the impact of the intervention, a retrospective review was performed before and after implementation to assess antiretroviral errors. Totals of 208 and 24 errors were identified before and after the intervention, respectively, resulting in a significant reduction in the overall error rate ( p < 0.001). In the postintervention group, significantly lower medication error rates were found in both patient admissions containing at least 1 medication error ( p < 0.001) and those with 2 or more errors ( p < 0.001). Significant reductions were also identified in each error type, including incorrect/incomplete medication regimen, incorrect dosing regimen, incorrect renal dose adjustment, incorrect administration, and the presence of a major drug-drug interaction. A regression tree selected ritonavir as the only specific medication that best predicted more errors preintervention ( p < 0.001); however, no antiretrovirals reliably predicted errors postintervention. An antiretroviral stewardship strategy for hospitalized HIV patients including prospective audit by staff pharmacists through use of an antiretroviral medication therapy checklist at the time of order verification decreased error rates. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
A multifaceted program for improving quality of care in intensive care units: IATROREF study.
Garrouste-Orgeas, Maite; Soufir, Lilia; Tabah, Alexis; Schwebel, Carole; Vesin, Aurelien; Adrie, Christophe; Thuong, Marie; Timsit, Jean Francois
2012-02-01
To test the effects of three multifaceted safety programs designed to decrease insulin administration errors, anticoagulant prescription and administration errors, and errors leading to accidental removal of endotracheal tubes and central venous catheters, respectively. Medical errors and adverse events are associated with increased mortality in intensive care patients, indicating an urgent need for prevention programs. Multicenter cluster-randomized study. One medical intensive care unit in a university hospital and two medical-surgical intensive care units in community hospitals belonging to the Outcomerea Study Group. Consecutive patients >18 yrs admitted from January 2007 to January 2008 to the intensive care units. We tested three multifaceted safety programs vs. standard care in random order, each over 2.5 months, after a 1.5-month observation period. Incidence rates of medical errors/1000 patient-days in the multifaceted safety program and standard-care groups were compared using adjusted hierarchical models. In 2117 patients with 15,014 patient-days, 8520 medical errors (567.5/1000 patient-days) were reported, including 1438 adverse events (16.9%, 95.8/1000 patient-days). The insulin multifaceted safety program significantly decreased errors during implementation (risk ratio 0.65; 95% confidence interval [CI] 0.52-0.82; p = .0003) and after implementation (risk ratio 0.51; 95% CI 0.35-0.73; p = .0004). A significant Hawthorne effect was found. The accidental tube/catheter removal multifaceted safety program decreased errors significantly during implementation (odds ratio [OR] 0.34; 95% CI 0.15-0.81; p = .01]) and nonsignificantly after implementation (OR 1.65; 95% CI 0.78-3.48). The anticoagulation multifaceted safety program was not significantly effective (OR 0.64; 95% CI 0.26-1.59) but produced a significant Hawthorne effect. A multifaceted program was effective in preventing insulin errors and accidental tube/catheter removal. Significant Hawthorne effects occurred, emphasizing the need for appropriately designed studies before definitively implementing strategies. clinicaltrials.gov Identifier: NCT00461461.
Specific impairments of rule induction in different frontal lobe subgroups.
Reverberi, Carlo; Lavaroni, Antonio; Gigli, Gian Luigi; Skrap, Miran; Shallice, Tim
2005-01-01
The neural correlates of inductive reasoning are still poorly understood. In order to explore them, we administered a revised version of the Brixton test, a rule attainment task, to a group of 40 patients with a focal frontal brain lesion of mixed aetiology and to 43 control subjects. To interpret an impairment on the test as suggesting an inductive reasoning deficit a number of alternative hypotheses need first to be considered, namely whether the Brixton impairment could be explained by: (i) a working memory deficit; (ii) a monitoring deficit; (iii) a difficulty in applying an already induced rule; (iv) greater impulsivity. The patients with left lateral (LL) frontal lesions were significantly impaired on the Brixton test; more importantly they were the only group in which none of the alternative hypotheses we explored proved able to explain the flawed performance. In sharp contrast, right lateral lesion patients did not make significantly more errors on the Brixton test than controls, but they produced three times more capture errors (a sign of impaired monitoring processes). The results were interpreted as suggesting functional dissociations between inductive reasoning, monitoring and working memory and a localisation of key processes for induction in left lateral frontal cortex and in right lateral cortex for monitoring and checking.
Chun, Ji-Won; Park, Hae-Jeong; Kim, Dai Jin; Kim, Eosu; Kim, Jae-Jin
2017-07-01
Conflict processing mediated by fronto-striatal regions may be influenced by emotional properties of stimuli. This study aimed to examine the effects of emotion repetition on cognitive control in a conflict-provoking situation. Twenty-one healthy subjects were scanned using functional magnetic resonance imaging while performing a sequential cognitive conflict task composed of emotional stimuli. The regional effects were analyzed according to the repetition or non-repetition of cognitive congruency and emotional valence between the preceding and current trials. Post-incongruence interference in error rate and reaction time was significantly smaller than post-congruence interference, particularly under repeated positive and non-repeated positive, respectively, and post-incongruence interference, compared to post-congruence interference, increased activity in the ACC, DLPFC, and striatum. ACC and DLPFC activities were significantly correlated with error rate or reaction time in some conditions, and fronto-striatal connections were related to the conflict processing heightened by negative emotion. These findings suggest that the repetition of emotional stimuli adaptively regulates cognitive control and the fronto-striatal circuit may engage in the conflict adaptation process induced by emotion repetition. Both repetition enhancement and repetition suppression of prefrontal activity may underlie the relationship between emotion and conflict adaptation. Copyright © 2017 Elsevier B.V. All rights reserved.
Shannon, Harlan E; Love, Patrick L
2005-12-01
Patients with epilepsy can have impaired cognitive abilities. Antiepileptic drugs (AEDs) may contribute to the cognitive deficits observed in patients with epilepsy, and have been shown to induce cognitive impairments in healthy individuals. However, there are few systematic data on the effects of AEDs on specific cognitive domains. We have previously evaluated a number of AEDs with respect to their effects on working memory. The purpose of the present study was to evaluate the effects of AEDs on attention as measured by five-choice serial reaction time behavior in nonepileptic rats. The GABA-related AEDs triazolam, phenobarbital, and chlordiazepoxide significantly disrupted performance by increasing errors of omission, whereas tiagabine, valproate, and gabapentin did not. The sodium channel blocker carbamazepine increased errors of omission at relatively high doses, whereas the sodium channel blockers phenytoin, topiramate, and lamotrigine were without significant effect. Levetiracetam had no effect on attention. The disruptions produced by triazolam, phenobarbital, chlordiazepoxide, and carbamazepine were similar in magnitude to the effects of the muscarinic cholinergic receptor antagonist scopolamine. The present results indicate that AEDs can disrupt attention, but there are differences among AEDs in the magnitude of the disruption in nonepileptic rats, with drugs that enhance GABA receptor function producing the most consistent disruption of attention.
Comparison of frequency-domain and time-domain rotorcraft vibration control methods
NASA Technical Reports Server (NTRS)
Gupta, N. K.
1984-01-01
Active control of rotor-induced vibration in rotorcraft has received significant attention recently. Two classes of techniques have been proposed. The more developed approach works with harmonic analysis of measured time histories and is called the frequency-domain approach. The more recent approach computes the control input directly using the measured time history data and is called the time-domain approach. The report summarizes the results of a theoretical investigation to compare the two approaches. Five specific areas were addressed: (1) techniques to derive models needed for control design (system identification methods), (2) robustness with respect to errors, (3) transient response, (4) susceptibility to noise, and (5) implementation difficulties. The system identification methods are more difficult for the time-domain models. The time-domain approach is more robust (e.g., has higher gain and phase margins) than the frequency-domain approach. It might thus be possible to avoid doing real-time system identification in the time-domain approach by storing models at a number of flight conditions. The most significant error source is the variation in open-loop vibrations caused by pilot inputs, maneuvers or gusts. The implementation requirements are similar except that the time-domain approach can be much simpler to implement if real-time system identification were not necessary.
Particle deposition in human respiratory system: deposition of concentrated hygroscopic aerosols.
Varghese, Suresh K; Gangamma, S
2009-06-01
In the nearly saturated human respiratory tract, the presence of water-soluble substances in the inhaled aerosols can cause change in the size distribution of the particles. This consequently alters the lung deposition profiles of the inhaled airborne particles. Similarly, the presence of high concentration of hygroscopic aerosols also affects the water vapor and temperature profiles in the respiratory tract. A model is presented to analyze these effects in human respiratory system. The model solves simultaneously the heat and mass transfer equations to determine the size evolution of respirable particles and gas-phase properties within human respiratory tract. First, the model predictions for nonhygroscopic aerosols are compared with experimental results. The model results are compared with experimental results of sodium chloride particles. The model reproduces the major features of the experimental data. The water vapor profile is significantly modified only when a high concentration of particles is present. The model is used to study the effect of equilibrium assumptions on particle deposition. Simulations show that an infinite dilution solution assumption to calculate the saturation equilibrium over droplet could induce errors in estimating particle growth. This error is significant in the case of particles of size greater than 1 mum and at number concentrations higher than 10(5)/cm(3).
Using heuristic evaluations to assess the safety of health information systems.
Carvalho, Christopher J; Borycki, Elizabeth M; Kushniruk, Andre W
2009-01-01
Health information systems (HISs) are typically seen as a mechanism for reducing medical errors. There is, however, evidence to prove that technology may actually be the cause of errors. As a result, it is crucial to fully test any system prior to its implementation. At present, evidence-based evaluation heuristics do not exist for assessing aspects of interface design that lead to medical errors. A three phase study was conducted to develop evidence-based heuristics for evaluating interfaces. Phase 1 consisted of a systematic review of the literature. In Phase 2 a comprehensive list of 33 evaluation heuristics was developed based on the review that could be used to test for potential technology induced errors. Phase 3 involved applying these healthcare specific heuristics to evaluate a HIS.
Soft error evaluation and vulnerability analysis in Xilinx Zynq-7010 system-on chip
NASA Astrophysics Data System (ADS)
Du, Xuecheng; He, Chaohui; Liu, Shuhuan; Zhang, Yao; Li, Yonghong; Xiong, Ceng; Tan, Pengkang
2016-09-01
Radiation-induced soft errors are an increasingly important threat to the reliability of modern electronic systems. In order to evaluate system-on chip's reliability and soft error, the fault tree analysis method was used in this work. The system fault tree was constructed based on Xilinx Zynq-7010 All Programmable SoC. Moreover, the soft error rates of different components in Zynq-7010 SoC were tested by americium-241 alpha radiation source. Furthermore, some parameters that used to evaluate the system's reliability and safety were calculated using Isograph Reliability Workbench 11.0, such as failure rate, unavailability and mean time to failure (MTTF). According to fault tree analysis for system-on chip, the critical blocks and system reliability were evaluated through the qualitative and quantitative analysis.
McKaig, Donald; Collins, Christine; Elsaid, Khaled A
2014-09-01
A study was conducted to evaluate the impact of a reengineered approach to electronic error reporting at a 719-bed multidisciplinary urban medical center. The main outcome of interest was the monthly reported medication errors during the preimplementation (20 months) and postimplementation (26 months) phases. An interrupted time series analysis was used to describe baseline errors, immediate change following implementation of the current electronic error-reporting system (e-ERS), and trend of error reporting during postimplementation. Errors were categorized according to severity using the National Coordinating Council for Medication Error Reporting and Prevention (NCC MERP) Medication Error Index classifications. Reported errors were further analyzed by reporter and error site. During preimplementation, the monthly reported errors mean was 40.0 (95% confidence interval [CI]: 36.3-43.7). Immediately following e-ERS implementation, monthly reported errors significantly increased by 19.4 errors (95% CI: 8.4-30.5). The change in slope of reported errors trend was estimated at 0.76 (95% CI: 0.07-1.22). Near misses and no-patient-harm errors accounted for 90% of all errors, while errors that caused increased patient monitoring or temporary harm accounted for 9% and 1%, respectively. Nurses were the most frequent reporters, while physicians were more likely to report high-severity errors. Medical care units accounted for approximately half of all reported errors. Following the intervention, there was a significant increase in reporting of prevented errors and errors that reached the patient with no resultant harm. This improvement in reporting was sustained for 26 months and has contributed to designing and implementing quality improvement initiatives to enhance the safety of the medication use process.
Hsu, Chi-Pin; Lin, Shang-Chih; Shih, Kao-Shang; Huang, Chang-Hung; Lee, Chian-Her
2014-12-01
After total knee replacement, the model-based Roentgen stereophotogrammetric analysis (RSA) technique has been used to monitor the status of prosthetic wear, misalignment, and even failure. However, the overlap of the prosthetic outlines inevitably increases errors in the estimation of prosthetic poses due to the limited amount of available outlines. In the literature, quite a few studies have investigated the problems induced by the overlapped outlines, and manual adjustment is still the mainstream. This study proposes two methods to automate the image processing of overlapped outlines prior to the pose registration of prosthetic models. The outline-separated method defines the intersected points and segments the overlapped outlines. The feature-recognized method uses the point and line features of the remaining outlines to initiate registration. Overlap percentage is defined as the ratio of overlapped to non-overlapped outlines. The simulated images with five overlapping percentages are used to evaluate the robustness and accuracy of the proposed methods. Compared with non-overlapped images, overlapped images reduce the number of outlines available for model-based RSA calculation. The maximum and root mean square errors for a prosthetic outline are 0.35 and 0.04 mm, respectively. The mean translation and rotation errors are 0.11 mm and 0.18°, respectively. The errors of the model-based RSA results are increased when the overlap percentage is beyond about 9%. In conclusion, both outline-separated and feature-recognized methods can be seamlessly integrated to automate the calculation of rough registration. This can significantly increase the clinical practicability of the model-based RSA technique.
Atmospheric Dispersion Effects in Weak Lensing Measurements
Plazas, Andrés Alejandro; Bernstein, Gary
2012-10-01
The wavelength dependence of atmospheric refraction causes elongation of finite-bandwidth images along the elevation vector, which produces spurious signals in weak gravitational lensing shear measurements unless this atmospheric dispersion is calibrated and removed to high precision. Because astrometric solutions and PSF characteristics are typically calibrated from stellar images, differences between the reference stars' spectra and the galaxies' spectra will leave residual errors in both the astrometric positions (dr) and in the second moment (width) of the wavelength-averaged PSF (dv) for galaxies.We estimate the level of dv that will induce spurious weak lensing signals in PSF-corrected galaxy shapes that exceed themore » statistical errors of the DES and the LSST cosmic-shear experiments. We also estimate the dr signals that will produce unacceptable spurious distortions after stacking of exposures taken at different airmasses and hour angles. We also calculate the errors in the griz bands, and find that dispersion systematics, uncorrected, are up to 6 and 2 times larger in g and r bands,respectively, than the requirements for the DES error budget, but can be safely ignored in i and z bands. For the LSST requirements, the factors are about 30, 10, and 3 in g, r, and i bands,respectively. We find that a simple correction linear in galaxy color is accurate enough to reduce dispersion shear systematics to insignificant levels in the r band for DES and i band for LSST,but still as much as 5 times than the requirements for LSST r-band observations. More complex corrections will likely be able to reduce the systematic cosmic-shear errors below statistical errors for LSST r band. But g-band effects remain large enough that it seems likely that induced systematics will dominate the statistical errors of both surveys, and cosmic-shear measurements should rely on the redder bands.« less
Factors associated with reporting of medication errors by Israeli nurses.
Kagan, Ilya; Barnoy, Sivia
2008-01-01
This study investigated medication error reporting among Israeli nurses, the relationship between nurses' personal views about error reporting, and the impact of the safety culture of the ward and hospital on this reporting. Nurses (n = 201) completed a questionnaire related to different aspects of error reporting (frequency, organizational norms of dealing with errors, and personal views on reporting). The higher the error frequency, the more errors went unreported. If the ward nurse manager corrected errors on the ward, error self-reporting decreased significantly. Ward nurse managers have to provide good role models.
Error monitoring issues for common channel signaling
NASA Astrophysics Data System (ADS)
Hou, Victor T.; Kant, Krishna; Ramaswami, V.; Wang, Jonathan L.
1994-04-01
Motivated by field data which showed a large number of link changeovers and incidences of link oscillations between in-service and out-of-service states in common channel signaling (CCS) networks, a number of analyses of the link error monitoring procedures in the SS7 protocol were performed by the authors. This paper summarizes the results obtained thus far and include the following: (1) results of an exact analysis of the performance of the error monitoring procedures under both random and bursty errors; (2) a demonstration that there exists a range of error rates within which the error monitoring procedures of SS7 may induce frequent changeovers and changebacks; (3) an analysis of the performance ofthe SS7 level-2 transmission protocol to determine the tolerable error rates within which the delay requirements can be met; (4) a demonstration that the tolerable error rate depends strongly on various link and traffic characteristics, thereby implying that a single set of error monitor parameters will not work well in all situations; (5) some recommendations on a customizable/adaptable scheme of error monitoring with a discussion on their implementability. These issues may be particularly relevant in the presence of anticipated increases in SS7 traffic due to widespread deployment of Advanced Intelligent Network (AIN) and Personal Communications Service (PCS) as well as for developing procedures for high-speed SS7 links currently under consideration by standards bodies.
NASA Astrophysics Data System (ADS)
Lin, Xiaomei; Chang, Penghui; Chen, Gehua; Lin, Jingjun; Liu, Ruixiang; Yang, Hao
2015-11-01
Our recent work has determined the carbon content in a melting ferroalloy by laser-induced breakdown spectroscopy (LIBS). The emission spectrum of carbon that we obtained in the laboratory is suitable for carbon content determination in a melting ferroalloy but we cannot get the expected results when this method is applied in industrial conditions: there is always an unacceptable error of around 4% between the actual value and the measured value. By comparing the measurement condition in the industrial condition with that in the laboratory, the results show that the temperature of the molten ferroalloy samples to be measured is constant under laboratory conditions while it decreases gradually under industrial conditions. However, temperature has a considerable impact on the measurement of carbon content, and this is the reason why there is always an error between the actual value and the measured value. In this paper we compare the errors of carbon content determination at different temperatures to find the optimum reference temperature range which can fit the requirements better in industrial conditions and, hence, make the measurement more accurate. The results of the comparative analyses show that the measured value of the carbon content in molten state (1620 K) is consistent with the nominal value of the solid standard sample (error within 0.7%). In fact, it is the most accurate measurement in the solid state. Based on this, we can effectively improve the accuracy of measurements in laboratory and can provide a reference standard of temperature for the measurement in industrial conditions. supported by National Natural Science Foundation of China (No. 51374040), and supported by Laser-Induced Plasma Spectroscopy Equipment Development and Application, China (No. 2014YQ120351)
Fisseni, Gregor; Pentzek, Michael; Abholz, Heinz-Harald
2008-02-01
GPs' recollections about their 'most serious errors in treatment' and about the consequences for themselves. Does it make a difference, who (else) contributed to the error, or to its discovery or disclosure? Anonymous questionnaire study concerning the 'three most serious errors in your career as a GP'. The participating doctors were given an operational definition of 'serious error'. They applied a special recall technique, using patient-induced associations to bring to mind former 'serious errors'. The recall method and the semi-structured 25-item questionnaire used were developed and piloted by the authors. The items were analysed quantitatively and by qualitative content analysis. General practices in the North Rhine region in Germany: 32 GPs anonymously reported about 75 'most serious errors'. In more than half of the cases analysed, other people contributed considerably to the GPs' serious errors. Most of the errors were discovered and disclosed to the patient by doctors: either by the GPs themselves, or by colleagues. A lot of GPs suffered loss of reputation and loss of patients. However, the number of patients staying with their GP clearly exceeded the number leaving their GP, depending on who else contributed to the error, who discovered it and who disclosed it to the patient. The majority of patients still trusted their GP after a serious error, especially if the GP was not the only one who contributed to the error and if the GP played an active role in the discovery and disclosure or the error.
Error-Induced Learning as a Resource-Adaptive Process in Young and Elderly Individuals
NASA Astrophysics Data System (ADS)
Ferdinand, Nicola K.; Weiten, Anja; Mecklinger, Axel; Kray, Jutta
Thorndike described in his law of effect [44] that actions followed by positive events are more likely to be repeated in the future, whereas actions that are followed by negative outcomes are less likely to be repeated. This implies that behavior is evaluated in the light of its potential consequences, and non-reward events (i.e., errors) must be detected for reinforcement learning to take place. In short, humans have to monitor their performance in order to detect and correct errors, and this allows them to successfully adapt their behavior to changing environmental demands and acquire new behavior, i.e., to learn.
MUSIC: MUlti-Scale Initial Conditions
NASA Astrophysics Data System (ADS)
Hahn, Oliver; Abel, Tom
2013-11-01
MUSIC generates multi-scale initial conditions with multiple levels of refinements for cosmological ‘zoom-in’ simulations. The code uses an adaptive convolution of Gaussian white noise with a real-space transfer function kernel together with an adaptive multi-grid Poisson solver to generate displacements and velocities following first- (1LPT) or second-order Lagrangian perturbation theory (2LPT). MUSIC achieves rms relative errors of the order of 10-4 for displacements and velocities in the refinement region and thus improves in terms of errors by about two orders of magnitude over previous approaches. In addition, errors are localized at coarse-fine boundaries and do not suffer from Fourier space-induced interference ringing.
Medical errors; causes, consequences, emotional response and resulting behavioral change
Bari, Attia; Khan, Rehan Ahmed; Rathore, Ahsan Waheed
2016-01-01
Objective: To determine the causes of medical errors, the emotional and behavioral response of pediatric medicine residents to their medical errors and to determine their behavior change affecting their future training. Methods: One hundred thirty postgraduate residents were included in the study. Residents were asked to complete questionnaire about their errors and responses to their errors in three domains: emotional response, learning behavior and disclosure of the error. The names of the participants were kept confidential. Data was analyzed using SPSS version 20. Results: A total of 130 residents were included. Majority 128(98.5%) of these described some form of error. Serious errors that occurred were 24(19%), 63(48%) minor, 24(19%) near misses,2(2%) never encountered an error and 17(12%) did not mention type of error but mentioned causes and consequences. Only 73(57%) residents disclosed medical errors to their senior physician but disclosure to patient’s family was negligible 15(11%). Fatigue due to long duty hours 85(65%), inadequate experience 66(52%), inadequate supervision 58(48%) and complex case 58(45%) were common causes of medical errors. Negative emotions were common and were significantly associated with lack of knowledge (p=0.001), missing warning signs (p=<0.001), not seeking advice (p=0.003) and procedural complications (p=0.001). Medical errors had significant impact on resident’s behavior; 119(93%) residents became more careful, increased advice seeking from seniors 109(86%) and 109(86%) started paying more attention to details. Intrinsic causes of errors were significantly associated with increased information seeking behavior and vigilance (p=0.003) and (p=0.01) respectively. Conclusion: Medical errors committed by residents have inadequate disclosure to senior physicians and result in negative emotions but there was positive change in their behavior, which resulted in improvement in their future training and patient care. PMID:27375682
Phenomenology of the sound-induced flash illusion.
Abadi, Richard V; Murphy, Jonathan S
2014-07-01
Past studies, using pairings of auditory tones and visual flashes, which were static and coincident in space but variable in time, demonstrated errors in judging the temporal patterning of the visual flashes-the sound-induced flash illusion. These errors took one of the two forms: under-reporting (sound-induced fusion) or over-reporting (sound-induced fission) of the flash numbers. Our study had three objectives: to examine the robustness of both illusions and to consider the effects of stimulus set and response bias. To this end, we used an extended range of fixed spatial location flash-tone pairings, examined stimuli that were variable in space and time and measured confidence in judging flash numbers. Our results indicated that the sound-induced flash illusion is a robust percept, a finding underpinned by the confidence measures. Sound-induced fusion was found to be more robust than sound-induced fission and a most likely outcome when high numbers of flashes were incorporated within an incongruent flash-tone pairing. Conversely, sound-induced fission was the most likely outcome for the flash-tone pairing which contained two flashes. Fission was also shown to be strongly driven by stimuli confounds such as categorical boundary conditions (e.g. flash-tone pairings with ≤2 flashes) and compressed response options. These findings suggest whilst both fission and fusion are associated with 'auditory driving', the differences in the occurrence and strength of the two illusions not only reflect the separate neuronal mechanisms underlying audio and visual signal processing, but also the test conditions that have been used to investigate the sound-induced flash illusion.
USDA-ARS?s Scientific Manuscript database
Since oxygen (O2) absorption of light becomes more pronounced at higher pressure levels, even a few meters distance between the target and the sensor can strongly affect canopy leaving Solar-Induced chlorophyll Fluorescence (SIF) retrievals. This study was conducted to quantify the consequent error ...
NASA Astrophysics Data System (ADS)
Saha, Subhajit; Mondal, Anindita
2018-04-01
We would like to rectify an error regarding the validity of the first law of thermodynamics (FLT) on the apparent horizon of a spatially flat Friedmann-Lemaitre-Robertson-Walker (FLRW) universe for the gravitationally induced particle creation scenario with constant specific entropy and an arbitrary particle creation rate (see Sect. 3.1 of original article)
Yu, Yifei; Luo, Linqing; Li, Bo; Guo, Linfeng; Yan, Jize; Soga, Kenichi
2015-10-01
The measured distance error caused by double peaks in the BOTDRs (Brillouin optical time domain reflectometers) system is a kind of Brillouin scattering spectrum (BSS) deformation, discussed and simulated for the first time in the paper, to the best of the authors' knowledge. Double peak, as a kind of Brillouin spectrum deformation, is important in the enhancement of spatial resolution, measurement accuracy, and crack detection. Due to the variances of the peak powers of the BSS along the fiber, the measured starting point of a step-shape frequency transition region is shifted and results in distance errors. Zero-padded short-time-Fourier-transform (STFT) can restore the transition-induced double peaks in the asymmetric and deformed BSS, thus offering more accurate and quicker measurements than the conventional Lorentz-fitting method. The recovering method based on the double-peak detection and corresponding BSS deformation can be applied to calculate the real starting point, which can improve the distance accuracy of the STFT-based BOTDR system.
Kalman filtered MR temperature imaging for laser induced thermal therapies.
Fuentes, D; Yung, J; Hazle, J D; Weinberg, J S; Stafford, R J
2012-04-01
The feasibility of using a stochastic form of Pennes bioheat model within a 3-D finite element based Kalman filter (KF) algorithm is critically evaluated for the ability to provide temperature field estimates in the event of magnetic resonance temperature imaging (MRTI) data loss during laser induced thermal therapy (LITT). The ability to recover missing MRTI data was analyzed by systematically removing spatiotemporal information from a clinical MR-guided LITT procedure in human brain and comparing predictions in these regions to the original measurements. Performance was quantitatively evaluated in terms of a dimensionless L(2) (RMS) norm of the temperature error weighted by acquisition uncertainty. During periods of no data corruption, observed error histories demonstrate that the Kalman algorithm does not alter the high quality temperature measurement provided by MR thermal imaging. The KF-MRTI implementation considered is seen to predict the bioheat transfer with RMS error < 4 for a short period of time, ∆t < 10 s, until the data corruption subsides. In its present form, the KF-MRTI method currently fails to compensate for consecutive for consecutive time periods of data loss ∆t > 10 sec.
Adams, C N; Kattawar, G W
1993-08-20
We have developed a Monte Carlo program that is capable of calculating both the scalar and the Stokes vector radiances in an atmosphere-ocean system in a single computer run. The correlated sampling technique is used to compute radiance distributions for both the scalar and the Stokes vector formulations simultaneously, thus permitting a direct comparison of the errors induced. We show the effect of the volume-scattering phase function on the errors in radiance calculations when one neglects polarization effects. The model used in this study assumes a conservative Rayleigh-scattering atmosphere above a flat ocean. Within the ocean, the volume-scattering function (the first element in the Mueller matrix) is varied according to both a Henyey-Greenstein phase function, with asymmetry factors G = 0.0, 0.5, and 0.9, and also to a Rayleigh-scattering phase function. The remainder of the reduced Mueller matrix for the ocean is taken to be that for Rayleigh scattering, which is consistent with ocean water measurement.
The Earth isn't flat: The (large) influence of topography on geodetic fault slip imaging.
NASA Astrophysics Data System (ADS)
Thompson, T. B.; Meade, B. J.
2017-12-01
While earthquakes both occur near and generate steep topography, most geodetic slip inversions assume that the Earth's surface is flat. We have developed a new boundary element tool, Tectosaur, with the capability to study fault and earthquake problems including complex fault system geometries, topography, material property contrasts, and millions of elements. Using Tectosaur, we study the model error induced by neglecting topography in both idealized synthetic fault models and for the cases of the MW=7.3 Landers and MW=8.0 Wenchuan earthquakes. Near the steepest topography, we find the use of flat Earth dislocation models may induce errors of more than 100% in the inferred slip magnitude and rake. In particular, neglecting topographic effects leads to an inferred shallow slip deficit. Thus, we propose that the shallow slip deficit observed in several earthquakes may be an artefact resulting from the systematic use of elastic dislocation models assuming a flat Earth. Finally, using this study as an example, we emphasize the dangerous potential for forward model errors to be amplified by an order of magnitude in inverse problems.
Revision of laser-induced damage threshold evaluation from damage probability data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bataviciute, Gintare; Grigas, Povilas; Smalakys, Linas
2013-04-15
In this study, the applicability of commonly used Damage Frequency Method (DFM) is addressed in the context of Laser-Induced Damage Threshold (LIDT) testing with pulsed lasers. A simplified computer model representing the statistical interaction between laser irradiation and randomly distributed damage precursors is applied for Monte Carlo experiments. The reproducibility of LIDT predicted from DFM is examined under both idealized and realistic laser irradiation conditions by performing numerical 1-on-1 tests. A widely accepted linear fitting resulted in systematic errors when estimating LIDT and its error bars. For the same purpose, a Bayesian approach was proposed. A novel concept of parametricmore » regression based on varying kernel and maximum likelihood fitting technique is introduced and studied. Such approach exhibited clear advantages over conventional linear fitting and led to more reproducible LIDT evaluation. Furthermore, LIDT error bars are obtained as a natural outcome of parametric fitting which exhibit realistic values. The proposed technique has been validated on two conventionally polished fused silica samples (355 nm, 5.7 ns).« less
Locked-mode avoidance and recovery without momentum input
NASA Astrophysics Data System (ADS)
Delgado-Aparicio, L.; Rice, J. E.; Wolfe, S.; Cziegler, I.; Gao, C.; Granetz, R.; Wukitch, S.; Terry, J.; Greenwald, M.; Sugiyama, L.; Hubbard, A.; Hugges, J.; Marmar, E.; Phillips, P.; Rowan, W.
2015-11-01
Error-field-induced locked-modes (LMs) have been studied in Alcator C-Mod at ITER-Bϕ, without NBI fueling and momentum input. Delay of the mode-onset and locked-mode recovery has been successfully obtained without external momentum input using Ion Cyclotron Resonance Heating (ICRH). The use of external heating in-sync with the error-field ramp-up resulted in a successful delay of the mode-onset when PICRH > 1 MW, which demonstrates the existence of a power threshold to ``unlock'' the mode; in the presence of an error field the L-mode discharge can transition into H-mode only when PICRH > 2 MW and at high densities, avoiding also the density pump-out. The effects of ion heating observed on unlocking the core plasma may be due to ICRH induced flows in the plasma boundary, or modifications of plasma profiles that changed the underlying turbulence. This work was performed under US DoE contracts including DE-FC02-99ER54512 and others at MIT, DE-FG03-96ER-54373 at University of Texas at Austin, and DE-AC02-09CH11466 at PPPL.
The effects of error augmentation on learning to walk on a narrow balance beam.
Domingo, Antoinette; Ferris, Daniel P
2010-10-01
Error augmentation during training has been proposed as a means to facilitate motor learning due to the human nervous system's reliance on performance errors to shape motor commands. We studied the effects of error augmentation on short-term learning of walking on a balance beam to determine whether it had beneficial effects on motor performance. Four groups of able-bodied subjects walked on a treadmill-mounted balance beam (2.5-cm wide) before and after 30 min of training. During training, two groups walked on the beam with a destabilization device that augmented error (Medium and High Destabilization groups). A third group walked on a narrower beam (1.27-cm) to augment error (Narrow). The fourth group practiced walking on the 2.5-cm balance beam (Wide). Subjects in the Wide group had significantly greater improvements after training than the error augmentation groups. The High Destabilization group had significantly less performance gains than the Narrow group in spite of similar failures per minute during training. In a follow-up experiment, a fifth group of subjects (Assisted) practiced with a device that greatly reduced catastrophic errors (i.e., stepping off the beam) but maintained similar pelvic movement variability. Performance gains were significantly greater in the Wide group than the Assisted group, indicating that catastrophic errors were important for short-term learning. We conclude that increasing errors during practice via destabilization and a narrower balance beam did not improve short-term learning of beam walking. In addition, the presence of qualitatively catastrophic errors seems to improve short-term learning of walking balance.
Lee, Eunjoo
2016-09-01
This study compared registered nurses' perceptions of safety climate and attitude toward medication error reporting before and after completing a hospital accreditation program. Medication errors are the most prevalent adverse events threatening patient safety; reducing underreporting of medication errors significantly improves patient safety. Safety climate in hospitals may affect medication error reporting. This study employed a longitudinal, descriptive design. Data were collected using questionnaires. A tertiary acute hospital in South Korea undergoing a hospital accreditation program. Nurses, pre- and post-accreditation (217 and 373); response rate: 58% and 87%, respectively. Hospital accreditation program. Perceived safety climate and attitude toward medication error reporting. The level of safety climate and attitude toward medication error reporting increased significantly following accreditation; however, measures of institutional leadership and management did not improve significantly. Participants' perception of safety climate was positively correlated with their attitude toward medication error reporting; this correlation strengthened following completion of the program. Improving hospitals' safety climate increased nurses' medication error reporting; interventions that help hospital administration and managers to provide more supportive leadership may facilitate safety climate improvement. Hospitals and their units should develop more friendly and intimate working environments that remove nurses' fear of penalties. Administration and managers should support nurses who report their own errors. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Ruangsetakit, Varee
2015-11-01
To re-examine relative accuracy of intraocular lens (IOL) power calculation of immersion ultrasound biometry (IUB) and partial coherence interferometry (PCI) based on a new approach that limits its interest on the cases in which the IUB's IOL and PCI's IOL assignments disagree. Prospective observational study of 108 eyes that underwent cataract surgeries at Taksin Hospital. Two halves ofthe randomly chosen sample eyes were implanted with the IUB- and PCI-assigned lens. Postoperative refractive errors were measured in the fifth week. More accurate calculation was based on significantly smaller mean absolute errors (MAEs) and root mean squared errors (RMSEs) away from emmetropia. The distributions of the errors were examined to ensure that the higher accuracy was significant clinically as well. The (MAEs, RMSEs) were smaller for PCI of (0.5106 diopter (D), 0.6037D) than for IUB of (0.7000D, 0.8062D). The higher accuracy was principally contributedfrom negative errors, i.e., myopia. The MAEs and RMSEs for (IUB, PCI)'s negative errors were (0.7955D, 0.5185D) and (0.8562D, 0.5853D). Their differences were significant. The 72.34% of PCI errors fell within a clinically accepted range of ± 0.50D, whereas 50% of IUB errors did. PCI's higher accuracy was significant statistically and clinically, meaning that lens implantation based on PCI's assignments could improve postoperative outcomes over those based on IUB's assignments.
Zucker, Jason; Mittal, Jaimie; Jen, Shin-Pung; Cheng, Lucy; Cennimo, David
2016-03-01
There is a high prevalence of HIV infection in Newark, New Jersey, with University Hospital admitting approximately 600 HIV-infected patients per year. Medication errors involving antiretroviral therapy (ART) could significantly affect treatment outcomes. The goal of this study was to evaluate the effectiveness of various stewardship interventions in reducing the prevalence of prescribing errors involving ART. This was a retrospective review of all inpatients receiving ART for HIV treatment during three distinct 6-month intervals over a 3-year period. During the first year, the baseline prevalence of medication errors was determined. During the second year, physician and pharmacist education was provided, and a computerized order entry system with drug information resources and prescribing recommendations was implemented. Prospective audit of ART orders with feedback was conducted in the third year. Analyses and comparisons were made across the three phases of this study. Of the 334 patients with HIV admitted in the first year, 45% had at least one antiretroviral medication error and 38% had uncorrected errors at the time of discharge. After education and computerized order entry, significant reductions in medication error rates were observed compared to baseline rates; 36% of 315 admissions had at least one error and 31% had uncorrected errors at discharge. While the prevalence of antiretroviral errors in year 3 was similar to that of year 2 (37% of 276 admissions), there was a significant decrease in the prevalence of uncorrected errors at discharge (12%) with the use of prospective review and intervention. Interventions, such as education and guideline development, can aid in reducing ART medication errors, but a committed stewardship program is necessary to elicit the greatest impact. © 2016 Pharmacotherapy Publications, Inc.
Kobashi, Hidenaga; Kamiya, Kazutaka; Ali, Mohamed A.; Igarashi, Akihito; Elewa, Mohamed Ehab M.; Shimizu, Kimiya
2015-01-01
Purpose To compare postoperative astigmatic correction between femtosecond lenticule extraction (FLEx) and small-incision lenticule extraction (SMILE) in eyes with myopic astigmatism. Methods We examined 26 eyes of 26 patients undergoing FLEx and 26 eyes of 26 patients undergoing SMILE to correct myopic astigmatism (manifest astigmatism of 1 diopter (D) or more). Visual acuity, cylindrical refraction, the predictability of the astigmatic correction, and the astigmatic vector components using Alpin’s method, were compared between the two groups 3 months postoperatively. Results We found no statistically significant difference in manifest cylindrical refraction (p=0.74) or in the percentage of eyes within ± 0.50 D of their refraction (p=0.47) after the two surgical procedures. Moreover, no statistically significant difference was detected between the groups in astigmatic vector components, namely, surgically induced astigmatism (0.80), target induced astigmatism (p=0.87), astigmatic correction index (p=0.77), angle of error (p=0.24), difference vector (p=0.76), index of success (p=0.91), flattening effect (p=0.79), and flattening index (p=0.84). Conclusions Both FLEx and SMILE procedures are essentially equivalent in correcting myopic astigmatism using vector analysis, suggesting that the lifting or non-lifting of the flap does not significantly affect astigmatic outcomes after these surgical procedures. PMID:25849381
Inducible error-prone repair in B. subtilis. Final report, September 1, 1979-June 30, 1981
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yasbin, R. E.
1981-06-01
The research performed under this contract has been concentrated on the relationship between inducible DNA repair systems, mutagenesis and the competent state in the gram positive bacterium Bacillus subtilis. The following results have been obtained from this research: (1) competent Bacillus subtilis cells have been developed into a sensitive tester system for carcinogens; (2) competent B. subtilis cells have an efficient excision-repair system, however, this system will not function on bacteriophage DNA taken into the cell via the process of transfection; (3) DNA polymerase III is essential in the mechanism of the process of W-reactivation; (4) B. subtilis strains curedmore » of their defective prophages have been isolated and are now being developed for gene cloning systems; (5) protoplasts of B. subtilis have been shown capable of acquiring DNA repair enzymes (i.e., enzyme therapy); and (6) a plasmid was characterized which enhanced inducible error-prone repair in a gram positive organism.« less